Sample records for geocoding positional error

  1. Modeling the probability distribution of positional errors incurred by residential address geocoding.

    PubMed

    Zimmerman, Dale L; Fang, Xiangming; Mazumdar, Soumya; Rushton, Gerard

    2007-01-10

    The assignment of a point-level geocode to subjects' residences is an important data assimilation component of many geographic public health studies. Often, these assignments are made by a method known as automated geocoding, which attempts to match each subject's address to an address-ranged street segment georeferenced within a streetline database and then interpolate the position of the address along that segment. Unfortunately, this process results in positional errors. Our study sought to model the probability distribution of positional errors associated with automated geocoding and E911 geocoding. Positional errors were determined for 1423 rural addresses in Carroll County, Iowa as the vector difference between each 100%-matched automated geocode and its true location as determined by orthophoto and parcel information. Errors were also determined for 1449 60%-matched geocodes and 2354 E911 geocodes. Huge (> 15 km) outliers occurred among the 60%-matched geocoding errors; outliers occurred for the other two types of geocoding errors also but were much smaller. E911 geocoding was more accurate (median error length = 44 m) than 100%-matched automated geocoding (median error length = 168 m). The empirical distributions of positional errors associated with 100%-matched automated geocoding and E911 geocoding exhibited a distinctive Greek-cross shape and had many other interesting features that were not capable of being fitted adequately by a single bivariate normal or t distribution. However, mixtures of t distributions with two or three components fit the errors very well. Mixtures of bivariate t distributions with few components appear to be flexible enough to fit many positional error datasets associated with geocoding, yet parsimonious enough to be feasible for nascent applications of measurement-error methodology to spatial epidemiology.

  2. Spatial autocorrelation among automated geocoding errors and its effects on testing for disease clustering

    PubMed Central

    Li, Jie; Fang, Xiangming

    2010-01-01

    Automated geocoding of patient addresses is an important data assimilation component of many spatial epidemiologic studies. Inevitably, the geocoding process results in positional errors. Positional errors incurred by automated geocoding tend to reduce the power of tests for disease clustering and otherwise affect spatial analytic methods. However, there are reasons to believe that the errors may often be positively spatially correlated and that this may mitigate their deleterious effects on spatial analyses. In this article, we demonstrate explicitly that the positional errors associated with automated geocoding of a dataset of more than 6000 addresses in Carroll County, Iowa are spatially autocorrelated. Furthermore, through two simulation studies of disease processes, including one in which the disease process is overlain upon the Carroll County addresses, we show that spatial autocorrelation among geocoding errors maintains the power of two tests for disease clustering at a level higher than that which would occur if the errors were independent. Implications of these results for cluster detection, privacy protection, and measurement-error modeling of geographic health data are discussed. PMID:20087879

  3. Effect of geocoding errors on traffic-related air pollutant exposure and concentration estimates

    EPA Science Inventory

    Exposure to traffic-related air pollutants is highest very near roads, and thus exposure estimates are sensitive to positional errors. This study evaluates positional and PM2.5 concentration errors that result from the use of automated geocoding methods and from linearized approx...

  4. Positional error and time-activity patterns in near-highway proximity studies: an exposure misclassification analysis

    PubMed Central

    2013-01-01

    Background The growing interest in research on the health effects of near-highway air pollutants requires an assessment of potential sources of error in exposure assignment techniques that rely on residential proximity to roadways. Methods We compared the amount of positional error in the geocoding process for three different data sources (parcels, TIGER and StreetMap USA) to a “gold standard” residential geocoding process that used ortho-photos, large multi-building parcel layouts or large multi-unit building floor plans. The potential effect of positional error for each geocoding method was assessed as part of a proximity to highway epidemiological study in the Boston area, using all participants with complete address information (N = 703). Hourly time-activity data for the most recent workday/weekday and non-workday/weekend were collected to examine time spent in five different micro-environments (inside of home, outside of home, school/work, travel on highway, and other). Analysis included examination of whether time-activity patterns were differentially distributed either by proximity to highway or across demographic groups. Results Median positional error was significantly higher in street network geocoding (StreetMap USA = 23 m; TIGER = 22 m) than parcel geocoding (8 m). When restricted to multi-building parcels and large multi-unit building parcels, all three geocoding methods had substantial positional error (parcels = 24 m; StreetMap USA = 28 m; TIGER = 37 m). Street network geocoding also differentially introduced greater amounts of positional error in the proximity to highway study in the 0–50 m proximity category. Time spent inside home on workdays/weekdays differed significantly by demographic variables (age, employment status, educational attainment, income and race). Time-activity patterns were also significantly different when stratified by proximity to highway, with those participants residing in the 0–50 m proximity category reporting significantly more time in the school/work micro-environment on workdays/weekdays than all other distance groups. Conclusions These findings indicate the potential for both differential and non-differential exposure misclassification due to geocoding error and time-activity patterns in studies of highway proximity. We also propose a multi-stage manual correction process to minimize positional error. Additional research is needed in other populations and geographic settings. PMID:24010639

  5. Positional error and time-activity patterns in near-highway proximity studies: an exposure misclassification analysis.

    PubMed

    Lane, Kevin J; Kangsen Scammell, Madeleine; Levy, Jonathan I; Fuller, Christina H; Parambi, Ron; Zamore, Wig; Mwamburi, Mkaya; Brugge, Doug

    2013-09-08

    The growing interest in research on the health effects of near-highway air pollutants requires an assessment of potential sources of error in exposure assignment techniques that rely on residential proximity to roadways. We compared the amount of positional error in the geocoding process for three different data sources (parcels, TIGER and StreetMap USA) to a "gold standard" residential geocoding process that used ortho-photos, large multi-building parcel layouts or large multi-unit building floor plans. The potential effect of positional error for each geocoding method was assessed as part of a proximity to highway epidemiological study in the Boston area, using all participants with complete address information (N = 703). Hourly time-activity data for the most recent workday/weekday and non-workday/weekend were collected to examine time spent in five different micro-environments (inside of home, outside of home, school/work, travel on highway, and other). Analysis included examination of whether time-activity patterns were differentially distributed either by proximity to highway or across demographic groups. Median positional error was significantly higher in street network geocoding (StreetMap USA = 23 m; TIGER = 22 m) than parcel geocoding (8 m). When restricted to multi-building parcels and large multi-unit building parcels, all three geocoding methods had substantial positional error (parcels = 24 m; StreetMap USA = 28 m; TIGER = 37 m). Street network geocoding also differentially introduced greater amounts of positional error in the proximity to highway study in the 0-50 m proximity category. Time spent inside home on workdays/weekdays differed significantly by demographic variables (age, employment status, educational attainment, income and race). Time-activity patterns were also significantly different when stratified by proximity to highway, with those participants residing in the 0-50 m proximity category reporting significantly more time in the school/work micro-environment on workdays/weekdays than all other distance groups. These findings indicate the potential for both differential and non-differential exposure misclassification due to geocoding error and time-activity patterns in studies of highway proximity. We also propose a multi-stage manual correction process to minimize positional error. Additional research is needed in other populations and geographic settings.

  6. Geocoding rural addresses in a community contaminated by PFOA: a comparison of methods.

    PubMed

    Vieira, Verónica M; Howard, Gregory J; Gallagher, Lisa G; Fletcher, Tony

    2010-04-21

    Location is often an important component of exposure assessment, and positional errors in geocoding may result in exposure misclassification. In rural areas, successful geocoding to a street address is limited by rural route boxes. Communities have assigned physical street addresses to rural route boxes as part of E911 readdressing projects for improved emergency response. Our study compared automated and E911 methods for recovering and geocoding valid street addresses and assessed the impact of positional errors on exposure classification. The current study is a secondary analysis of existing data that included 135 addresses self-reported by participants of a rural community study who were exposed via public drinking water to perfluorooctanoate (PFOA) released from a DuPont facility in Parkersburg, West Virginia. We converted pre-E911 to post-E911 addresses using two methods: automated ZP4 address-correction software with the U.S. Postal Service LACS database and E911 data provided by Wood County, West Virginia. Addresses were geocoded using TeleAtlas, an online commercial service, and ArcView with StreetMap Premium North America NAVTEQ 2008 enhanced street dataset. We calculated positional errors using GPS measurements collected at each address and assessed exposure based on geocoded location in relation to public water pipes. The county E911 data converted 89% of the eligible addresses compared to 35% by ZP4 LACS. ArcView/NAVTEQ geocoded more addresses (n = 130) and with smaller median distance between geocodes and GPS coordinates (39 meters) than TeleAtlas (n = 85, 188 meters). Without E911 address conversion, 25% of the geocodes would have been more than 1000 meters from the true location. Positional errors in TeleAtlas geocoding resulted in exposure misclassification of seven addresses whereas ArcView/NAVTEQ methods did not misclassify any addresses. Although the study was limited by small numbers, our results suggest that the use of county E911 data in rural areas increases the rate of successful geocoding. Furthermore, positional accuracy of rural addresses in the study area appears to vary by geocoding method. In a large epidemiological study investigating the health effects of PFOA-contaminated public drinking water, this could potentially result in exposure misclassification if addresses are incorrectly geocoded to a street segment not serviced by public water.

  7. Local indicators of geocoding accuracy (LIGA): theory and application

    PubMed Central

    Jacquez, Geoffrey M; Rommel, Robert

    2009-01-01

    Background Although sources of positional error in geographic locations (e.g. geocoding error) used for describing and modeling spatial patterns are widely acknowledged, research on how such error impacts the statistical results has been limited. In this paper we explore techniques for quantifying the perturbability of spatial weights to different specifications of positional error. Results We find that a family of curves describes the relationship between perturbability and positional error, and use these curves to evaluate sensitivity of alternative spatial weight specifications to positional error both globally (when all locations are considered simultaneously) and locally (to identify those locations that would benefit most from increased geocoding accuracy). We evaluate the approach in simulation studies, and demonstrate it using a case-control study of bladder cancer in south-eastern Michigan. Conclusion Three results are significant. First, the shape of the probability distributions of positional error (e.g. circular, elliptical, cross) has little impact on the perturbability of spatial weights, which instead depends on the mean positional error. Second, our methodology allows researchers to evaluate the sensitivity of spatial statistics to positional accuracy for specific geographies. This has substantial practical implications since it makes possible routine sensitivity analysis of spatial statistics to positional error arising in geocoded street addresses, global positioning systems, LIDAR and other geographic data. Third, those locations with high perturbability (most sensitive to positional error) and high leverage (that contribute the most to the spatial weight being considered) will benefit the most from increased positional accuracy. These are rapidly identified using a new visualization tool we call the LIGA scatterplot. Herein lies a paradox for spatial analysis: For a given level of positional error increasing sample density to more accurately follow the underlying population distribution increases perturbability and introduces error into the spatial weights matrix. In some studies positional error may not impact the statistical results, and in others it might invalidate the results. We therefore must understand the relationships between positional accuracy and the perturbability of the spatial weights in order to have confidence in a study's results. PMID:19863795

  8. Accuracy of two geocoding methods for geographic information system-based exposure assessment in epidemiological studies.

    PubMed

    Faure, Elodie; Danjou, Aurélie M N; Clavel-Chapelon, Françoise; Boutron-Ruault, Marie-Christine; Dossus, Laure; Fervers, Béatrice

    2017-02-24

    Environmental exposure assessment based on Geographic Information Systems (GIS) and study participants' residential proximity to environmental exposure sources relies on the positional accuracy of subjects' residences to avoid misclassification bias. Our study compared the positional accuracy of two automatic geocoding methods to a manual reference method. We geocoded 4,247 address records representing the residential history (1990-2008) of 1,685 women from the French national E3N cohort living in the Rhône-Alpes region. We compared two automatic geocoding methods, a free-online geocoding service (method A) and an in-house geocoder (method B), to a reference layer created by manually relocating addresses from method A (method R). For each automatic geocoding method, positional accuracy levels were compared according to the urban/rural status of addresses and time-periods (1990-2000, 2001-2008), using Chi Square tests. Kappa statistics were performed to assess agreement of positional accuracy of both methods A and B with the reference method, overall, by time-periods and by urban/rural status of addresses. Respectively 81.4% and 84.4% of addresses were geocoded to the exact address (65.1% and 61.4%) or to the street segment (16.3% and 23.0%) with methods A and B. In the reference layer, geocoding accuracy was higher in urban areas compared to rural areas (74.4% vs. 10.5% addresses geocoded to the address or interpolated address level, p < 0.0001); no difference was observed according to the period of residence. Compared to the reference method, median positional errors were 0.0 m (IQR = 0.0-37.2 m) and 26.5 m (8.0-134.8 m), with positional errors <100 m for 82.5% and 71.3% of addresses, for method A and method B respectively. Positional agreement of method A and method B with method R was 'substantial' for both methods, with kappa coefficients of 0.60 and 0.61 for methods A and B, respectively. Our study demonstrates the feasibility of geocoding residential addresses in epidemiological studies not initially recorded for environmental exposure assessment, for both recent addresses and residence locations more than 20 years ago. Accuracy of the two automatic geocoding methods was comparable. The in-house method (B) allowed a better control of the geocoding process and was less time consuming.

  9. Positional accuracy and geographic bias of four methods of geocoding in epidemiologic research.

    PubMed

    Schootman, Mario; Sterling, David A; Struthers, James; Yan, Yan; Laboube, Ted; Emo, Brett; Higgs, Gary

    2007-06-01

    We examined the geographic bias of four methods of geocoding addresses using ArcGIS, commercial firm, SAS/GIS, and aerial photography. We compared "point-in-polygon" (ArcGIS, commercial firm, and aerial photography) and the "look-up table" method (SAS/GIS) to allocate addresses to census geography, particularly as it relates to census-based poverty rates. We randomly selected 299 addresses of children treated for asthma at an urban emergency department (1999-2001). The coordinates of the building address side door were obtained by constant offset based on ArcGIS and a commercial firm and true ground location based on aerial photography. Coordinates were available for 261 addresses across all methods. For 24% to 30% of geocoded road/door coordinates the positional error was 51 meters or greater, which was similar across geocoding methods. The mean bearing was -26.8 degrees for the vector of coordinates based on aerial photography and ArcGIS and 8.5 degrees for the vector based on aerial photography and the commercial firm (p < 0.0001). ArcGIS and the commercial firm performed very well relative to SAS/GIS in terms of allocation to census geography. For 20%, the door location based on aerial photography was assigned to a different block group compared to SAS/GIS. The block group poverty rate varied at least two standard deviations for 6% to 7% of addresses. We found important differences in distance and bearing between geocoding relative to aerial photography. Allocation of locations based on aerial photography to census-based geographic areas could lead to substantial errors.

  10. [Comparison of Google and Yahoo applications for geocoding of postal addresses in epidemiological studies].

    PubMed

    Quesada, Jose Antonio; Nolasco, Andreu; Moncho, Joaquín

    2013-01-01

    Geocoding is the assignment of geographic coordinates to spatial points, which often are postal addresses. The error made in applying this process can introduce bias in estimates of spatiotemporal models in epidemiological studies. No studies have been found to measure the error made in applying this process in Spanish cities. The objective is to evaluate the errors in magnitude and direction from two free sources (Google and Yahoo) with regard to a GPS in two Spanish cities. 30 addresses were geocoded with those two sources and the GPS in Santa Pola (Alicante) and Alicante city. The distances were calculated in metres (median, CI95%) between the sources and the GPS, globally and according to the status reported by each source. The directionality of the error was evaluated by calculating the location quadrant and applying a Chi-Square test. The GPS error was evaluated by geocoding 11 addresses twice at 4 days interval. The overall median in Google-GPS was 23,2 metres (16,0-32,1) for Santa Pola, and 21,4 meters (14,9-31,1) for Alicante. The overall median in Yahoo was 136,0 meters (19,2-318,5) for Santa Pola, and 23,8 meters (13,6- 29,2) for Alicante. Between the 73% and 90% were geocoded by status as "exact or interpolated" (minor error), where Goggle and Yahoo had a median error between 19 and 23 metres in the two cities. The GPS had a median error of 13.8 meters (6,7-17,8). No error directionality was detected. Google error is acceptable and stable in the two cities, so that it is a reliable source for Para medir elgeocoding addresses in Spain in epidemiological studies.

  11. [Who Hits the Mark? A Comparative Study of the Free Geocoding Services of Google and OpenStreetMap].

    PubMed

    Lemke, D; Mattauch, V; Heidinger, O; Hense, H W

    2015-09-01

    Geocoding, the process of converting textual information (addresses) into geographic coordinates is increasingly used in public health/epidemiological research and practice. To date, little attention has been paid to geocoding quality and its impact on different types of spatially-related health studies. The primary aim of this study was to compare 2 freely available geocoding services (Google and OpenStreetMap) with regard to matching rate (percentage of address records capable of being geocoded) and positional accuracy (distance between geocodes and the ground truth locations). Residential addresses were geocoded by the NRW state office for information and technology and were considered as reference data (gold standard). The gold standard included the coordinates, the quality of the addresses (4 categories), and a binary urbanity indicator based on the CORINE land cover data. 2 500 addresses were randomly sampled after stratification for address quality and urbanity indicator (approximately 20 000 addresses). These address samples were geocoded using the geocoding services from Google and OSM. In general, both geocoding services showed a decrease in the matching rate with decreasing address quality and urbanity. Google showed consistently a higher completeness than OSM (>93 vs. >82%). Also, the cartographic confounding between urban and rural regions was less distinct with Google's geocoding API. Regarding the positional accuracy of the geo-coordinates, Google also showed the smallest deviations from the reference coordinates, with a median of <9 vs. <175.8 m. The cumulative density function derived from the positional accuracy showed for Google that nearly 95% and for OSM 50% of the addresses were geocoded within <50 m of their reference coordinates. The geocoding API from Google is superior to OSM regarding completeness and positional accuracy of the geocoded addresses. On the other hand, Google has several restrictions, such as the limitation of the requests to 2 500 addresses per 24 h and the presentation of the results exclusively on Google Maps, which may complicate the use for scientific purposes. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Use of attribute association error probability estimates to evaluate quality of medical record geocodes.

    PubMed

    Klaus, Christian A; Carrasco, Luis E; Goldberg, Daniel W; Henry, Kevin A; Sherman, Recinda L

    2015-09-15

    The utility of patient attributes associated with the spatiotemporal analysis of medical records lies not just in their values but also the strength of association between them. Estimating the extent to which a hierarchy of conditional probability exists between patient attribute associations such as patient identifying fields, patient and date of diagnosis, and patient and address at diagnosis is fundamental to estimating the strength of association between patient and geocode, and patient and enumeration area. We propose a hierarchy for the attribute associations within medical records that enable spatiotemporal relationships. We also present a set of metrics that store attribute association error probability (AAEP), to estimate error probability for all attribute associations upon which certainty in a patient geocode depends. A series of experiments were undertaken to understand how error estimation could be operationalized within health data and what levels of AAEP in real data reveal themselves using these methods. Specifically, the goals of this evaluation were to (1) assess if the concept of our error assessment techniques could be implemented by a population-based cancer registry; (2) apply the techniques to real data from a large health data agency and characterize the observed levels of AAEP; and (3) demonstrate how detected AAEP might impact spatiotemporal health research. We present an evaluation of AAEP metrics generated for cancer cases in a North Carolina county. We show examples of how we estimated AAEP for selected attribute associations and circumstances. We demonstrate the distribution of AAEP in our case sample across attribute associations, and demonstrate ways in which disease registry specific operations influence the prevalence of AAEP estimates for specific attribute associations. The effort to detect and store estimates of AAEP is worthwhile because of the increase in confidence fostered by the attribute association level approach to the assessment of uncertainty in patient geocodes, relative to existing geocoding related uncertainty metrics.

  13. Satellite SAR geocoding with refined RPC model

    NASA Astrophysics Data System (ADS)

    Zhang, Lu; Balz, Timo; Liao, Mingsheng

    2012-04-01

    Recent studies have proved that the Rational Polynomial Camera (RPC) model is able to act as a reliable replacement of the rigorous Range-Doppler (RD) model for the geometric processing of satellite SAR datasets. But its capability in absolute geolocation of SAR images has not been evaluated quantitatively. Therefore, in this article the problems of error analysis and refinement of SAR RPC model are primarily investigated to improve the absolute accuracy of SAR geolocation. Range propagation delay and azimuth timing error are identified as two major error sources for SAR geolocation. An approach based on SAR image simulation and real-to-simulated image matching is developed to estimate and correct these two errors. Afterwards a refined RPC model can be built from the error-corrected RD model and then used in satellite SAR geocoding. Three experiments with different settings are designed and conducted to comprehensively evaluate the accuracies of SAR geolocation with both ordinary and refined RPC models. All the experimental results demonstrate that with RPC model refinement the absolute location accuracies of geocoded SAR images can be improved significantly, particularly in Easting direction. In another experiment the computation efficiencies of SAR geocoding with both RD and RPC models are compared quantitatively. The results show that by using the RPC model such efficiency can be remarkably improved by at least 16 times. In addition the problem of DEM data selection for SAR image simulation in RPC model refinement is studied by a comparative experiment. The results reveal that the best choice should be using the proper DEM datasets of spatial resolution comparable to that of the SAR images.

  14. Validation of the geographic position of EPER-Spain industries

    PubMed Central

    García-Pérez, Javier; Boldo, Elena; Ramis, Rebeca; Vidal, Enrique; Aragonés, Nuria; Pérez-Gómez, Beatriz; Pollán, Marina; López-Abente, Gonzalo

    2008-01-01

    Background The European Pollutant Emission Register in Spain (EPER-Spain) is a public inventory of pollutant industries created by decision of the European Union. The location of these industries is geocoded and the first published data correspond to 2001. Publication of these data will allow for quantification of the effect of proximity to one or more such plant on cancer and all-cause mortality observed in nearby towns. However, as errors have been detected in the geocoding of many of the pollutant foci shown in the EPER, it was decided that a validation study should be conducted into the accuracy of these co-ordinates. EPER-Spain geographic co-ordinates were drawn from the European Environment Agency (EEA) server and the Spanish Ministry of the Environment (MOE). The Farm Plot Geographic Information System (Sistema de Información Geográfica de Parcelas Agrícolas) (SIGPAC) enables orthophotos (digitalized aerial images) of any territorial point across Spain to be obtained. Through a search of co-ordinates in the SIGPAC, all the industrial foci (except farms) were located. The quality criteria used to ascertain possible errors in industrial location were high, medium and low quality, where industries were situated at a distance of less than 500 metres, more than 500 metres but less than 1 kilometre, and more than 1 kilometre from their real locations, respectively. Results Insofar as initial registry quality was concerned, 84% of industrial complexes were inaccurately positioned (low quality) according to EEA data versus 60% for Spanish MOE data. The distribution of the distances between the original and corrected co-ordinates for each of the industries on the registry revealed that the median error was 2.55 kilometres for Spain overall (according to EEA data). The Autonomous Regions that displayed most errors in industrial geocoding were Murcia, Canary Islands, Andalusia and Madrid. Correct co-ordinates were successfully allocated to 100% of EPER-Spain industries. Conclusion Knowing the exact location of pollutant foci is vital to obtain reliable and valid conclusions in any study where distance to the focus is a decisive factor, as in the case of the consequences of industrial pollution on the health of neighbouring populations. PMID:18190678

  15. A multifaceted comparison of ArcGIS and MapMarker for automated geocoding.

    PubMed

    Kumar, Sanjaya; Liu, Ming; Hwang, Syni-An

    2012-11-01

    Geocoding is increasingly being used for public health surveillance and spatial epidemiology studies. Public health departments in the United States of America (USA) often use this approach to investigate disease outbreaks and clusters or assign health records to appropriate geographic units. We evaluated two commonly used geocoding software packages, ArcGIS and MapMarker, for automated geocoding of a large number of residential addresses from health administrative data in New York State, USA to better understand their features, performance and limitations. The comparison was based on three metrics of evaluation: completeness (or match rate), geocode similarity and positional accuracy. Of the 551,798 input addresses, 318,302 (57.7%) were geocoded by MapMarker and 420,813 (76.3%) by the ArcGIS composite address locator. High similarity between the geocodes assigned by the two methods was found, especially in suburban and urban areas. Among addresses with a distance of greater than 100 m between the geocodes assigned by the two packages, the point assigned by ArcGIS was closer to the associated parcel centroid ("true" location) compared with that assigned by MapMarker. In addition, the composite address locator in ArcGIS allows users to fully utilise available reference data, which consequently results in better geocoding results. However, the positional differences found were minimal, and a large majority of addresses were placed on the same locations by both geocoding packages. Using both methods and combining the results can maximise match rates and save the time needed for manual geocoding.

  16. Forest pests and home values: The importance of accuracy in damage assessment and geocoding of properties

    Treesearch

    Klaus Moeltner; Christine E. Blinn; Thomas P. Holmes

    2017-01-01

    We examine the impact of measurement errors in geocoding of property locations and in the assessment of Mountain Pine Beetle-induced tree damage within the proximity of a given residence on estimated losses in home values. For our sample of homes in the wildland-urban interface of the Colorado front range and using a novel matching estimator with Bayesian regression...

  17. The Effect of Administrative Boundaries and Geocoding Error on Cancer Rates in California

    PubMed Central

    Goldberg, Daniel W.; Cockburn, Myles G.

    2012-01-01

    Geocoding is often used to produce maps of disease rates from the diagnosis addresses of incident cases to assist with disease surveillance, prevention, and control. In this process, diagnosis addresses are converted into latitude/longitude pairs which are then aggregated to produce rates at varying geographic scales such as Census tracts, neighborhoods, cities, counties, and states. The specific techniques used within geocoding systems have an impact on where the output geocode is located and can therefore have an effect on the derivation of disease rates at different geographic aggregations. This paper investigates how county-level cancer rates are affected by the choice of interpolation method when case data are geocoded to the ZIP code level. Four commonly used areal unit interpolation techniques are applied and the output of each is used to compute crude county-level five-year incidence rates of all cancers in California. We found that the rates observed for 44 out of the 58 counties in California vary based on which interpolation method is used, with rates in some counties increasing by nearly 400% between interpolation methods. PMID:22469490

  18. An address geocoding method for improving rural spatial information infrastructure

    NASA Astrophysics Data System (ADS)

    Pan, Yuchun; Chen, Baisong; Lu, Zhou; Li, Shuhua; Zhang, Jingbo; Zhou, YanBing

    2010-11-01

    The transition of rural and agricultural management from divisional to integrated mode has highlighted the importance of data integration and sharing. Current data are mostly collected by specific department to satisfy their own needs and lake of considering on wider potential uses. This led to great difference in data format, semantic, and precision even in same area, which is a significant barrier for constructing an integrated rural spatial information system to support integrated management and decision-making. Considering the rural cadastral management system and postal zones, the paper designs a rural address geocoding method based on rural cadastral parcel. It puts forward a geocoding standard which consists of absolute position code, relative position code and extended code. It designs a rural geocoding database model, and addresses collection and update model. Then, based on the rural address geocoding model, it proposed a data model for rural agricultural resources management. The results show that the address coding based on postal code is stable and easy to memorize, two-dimensional coding based on the direction and distance is easy to be located and memorized, while extended code can enhance the extensibility and flexibility of address geocoding.

  19. The effect of administrative boundaries and geocoding error on cancer rates in California.

    PubMed

    Goldberg, Daniel W; Cockburn, Myles G

    2012-04-01

    Geocoding is often used to produce maps of disease rates from the diagnosis addresses of incident cases to assist with disease surveillance, prevention, and control. In this process, diagnosis addresses are converted into latitude/longitude pairs which are then aggregated to produce rates at varying geographic scales such as Census tracts, neighborhoods, cities, counties, and states. The specific techniques used within geocoding systems have an impact on where the output geocode is located and can therefore have an effect on the derivation of disease rates at different geographic aggregations. This paper investigates how county-level cancer rates are affected by the choice of interpolation method when case data are geocoded to the ZIP code level. Four commonly used areal unit interpolation techniques are applied and the output of each is used to compute crude county-level five-year incidence rates of all cancers in California. We found that the rates observed for 44 out of the 58 counties in California vary based on which interpolation method is used, with rates in some counties increasing by nearly 400% between interpolation methods. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. A Different Web-Based Geocoding Service Using Fuzzy Techniques

    NASA Astrophysics Data System (ADS)

    Pahlavani, P.; Abbaspour, R. A.; Zare Zadiny, A.

    2015-12-01

    Geocoding - the process of finding position based on descriptive data such as address or postal code - is considered as one of the most commonly used spatial analyses. Many online map providers such as Google Maps, Bing Maps and Yahoo Maps present geocoding as one of their basic capabilities. Despite the diversity of geocoding services, users usually face some limitations when they use available online geocoding services. In existing geocoding services, proximity and nearness concept is not modelled appropriately as well as these services search address only by address matching based on descriptive data. In addition there are also some limitations in display searching results. Resolving these limitations can enhance efficiency of the existing geocoding services. This paper proposes the idea of integrating fuzzy technique with geocoding process to resolve these limitations. In order to implement the proposed method, a web-based system is designed. In proposed method, nearness to places is defined by fuzzy membership functions and multiple fuzzy distance maps are created. Then these fuzzy distance maps are integrated using fuzzy overlay technique for obtain the results. Proposed methods provides different capabilities for users such as ability to search multi-part addresses, searching places based on their location, non-point representation of results as well as displaying search results based on their priority.

  1. Integrating Address Geocoding, Land Use Regression, and Spatiotemporal Geostatistical Estimation for Groundwater Tetrachloroethylene

    PubMed Central

    Messier, Kyle P.; Akita, Yasuyuki; Serre, Marc L.

    2012-01-01

    Geographic Information Systems (GIS) based techniques are cost-effective and efficient methods used by state agencies and epidemiology researchers for estimating concentration and exposure. However, budget limitations have made statewide assessments of contamination difficult, especially in groundwater media. Many studies have implemented address geocoding, land use regression, and geostatistics independently, but this is the first to examine the benefits of integrating these GIS techniques to address the need of statewide exposure assessments. A novel framework for concentration exposure is introduced that integrates address geocoding, land use regression (LUR), below detect data modeling, and Bayesian Maximum Entropy (BME). A LUR model was developed for Tetrachloroethylene that accounts for point sources and flow direction. We then integrate the LUR model into the BME method as a mean trend while also modeling below detects data as a truncated Gaussian probability distribution function. We increase available PCE data 4.7 times from previously available databases through multistage geocoding. The LUR model shows significant influence of dry cleaners at short ranges. The integration of the LUR model as mean trend in BME results in a 7.5% decrease in cross validation mean square error compared to BME with a constant mean trend. PMID:22264162

  2. Integrating address geocoding, land use regression, and spatiotemporal geostatistical estimation for groundwater tetrachloroethylene.

    PubMed

    Messier, Kyle P; Akita, Yasuyuki; Serre, Marc L

    2012-03-06

    Geographic information systems (GIS) based techniques are cost-effective and efficient methods used by state agencies and epidemiology researchers for estimating concentration and exposure. However, budget limitations have made statewide assessments of contamination difficult, especially in groundwater media. Many studies have implemented address geocoding, land use regression, and geostatistics independently, but this is the first to examine the benefits of integrating these GIS techniques to address the need of statewide exposure assessments. A novel framework for concentration exposure is introduced that integrates address geocoding, land use regression (LUR), below detect data modeling, and Bayesian Maximum Entropy (BME). A LUR model was developed for tetrachloroethylene that accounts for point sources and flow direction. We then integrate the LUR model into the BME method as a mean trend while also modeling below detects data as a truncated Gaussian probability distribution function. We increase available PCE data 4.7 times from previously available databases through multistage geocoding. The LUR model shows significant influence of dry cleaners at short ranges. The integration of the LUR model as mean trend in BME results in a 7.5% decrease in cross validation mean square error compared to BME with a constant mean trend.

  3. CCRS proposal for evaluating LANDSAT-4 MSS and TM data

    NASA Technical Reports Server (NTRS)

    Strome, W. M.; Cihlar, J.; Goodenough, D. G.; Guertin, F. E. (Principal Investigator); Guindon, B.; Murphy, J.; Butlin, J. M.; Duff, P.; Fitzgerald, A.; Grieve, G.

    1984-01-01

    The measurement of registration errors in LANDSAT MSS data is discussed as well as the development of a revised algorithm for the radiometric calibration of TM data and the production of a geocoded TM image.

  4. a Discussion about Effective Ways of Basic Resident Register on GIS

    NASA Astrophysics Data System (ADS)

    Oku, Naoya; Nonaka, Yasuaki; Ito, Yutaka

    2016-06-01

    In Japan, each municipality keeps a database of every resident's name, address, gender and date of birth called the Basic Resident Register. If the address information in the register is converted into coordinates by geocoding, it can be plotted as point data on a map. This would enable prompt evacuation from disaster, analysis of distribution of residents, integrating statistics and so on. Further, it can be used for not only analysis of the current situation but also future planning. However, the geographic information system (GIS) incorporating the Basic Resident Register is not widely used in Japan because of the following problems: - Geocoding In order to plot address point data, it is necessary to match the Basic Resident Register and the address dictionary by using the address as a key. The information in the Basic Resident Register does not always match the actual addresses. As the register is based on applications made by residents, the information is prone to errors, such as incorrect Kanji characters. - Security policy on personal information In the register, the address of a resident is linked with his/her name and date of birth. If the information in the Basic Resident Register were to be leaked, it could be used for malicious purposes. This paper proposes solutions to the above problems. The suitable solutions for the problems depend on the purpose of use, thus it is important that the purpose should be defined and a suitable way of the application for each purpose should be chosen. In this paper, we mainly focus on the specific purpose of use: to analyse the distribution of the residents. We provide two solutions to improve the matching rate in geocoding. First, regarding errors in Kanji characters, a correction list of possible errors should be compiled in advance. Second, some sort of analyses such as distribution of residents may not require exactly correct position for the address point. Therefore we set the matching level in order: prefecture, city, town, city-block, house-code, house, and decided to accept up to city-block level for the matching. Moreover, in terms of security policy on personal information, some part of information may not be needed for the distribution analysis. For example, the personal information like resident's name should be excluded from the attribute of address point in order to secure the safety operation of the system.

  5. Impact of geocoding methods on associations between long-term exposure to urban air pollution and lung function.

    PubMed

    Jacquemin, Bénédicte; Lepeule, Johanna; Boudier, Anne; Arnould, Caroline; Benmerad, Meriem; Chappaz, Claire; Ferran, Joane; Kauffmann, Francine; Morelli, Xavier; Pin, Isabelle; Pison, Christophe; Rios, Isabelle; Temam, Sofia; Künzli, Nino; Slama, Rémy; Siroux, Valérie

    2013-09-01

    Errors in address geocodes may affect estimates of the effects of air pollution on health. We investigated the impact of four geocoding techniques on the association between urban air pollution estimated with a fine-scale (10 m × 10 m) dispersion model and lung function in adults. We measured forced expiratory volume in 1 sec (FEV1) and forced vital capacity (FVC) in 354 adult residents of Grenoble, France, who were participants in two well-characterized studies, the Epidemiological Study on the Genetics and Environment on Asthma (EGEA) and the European Community Respiratory Health Survey (ECRHS). Home addresses were geocoded using individual building matching as the reference approach and three spatial interpolation approaches. We used a dispersion model to estimate mean PM10 and nitrogen dioxide concentrations at each participant's address during the 12 months preceding their lung function measurements. Associations between exposures and lung function parameters were adjusted for individual confounders and same-day exposure to air pollutants. The geocoding techniques were compared with regard to geographical distances between coordinates, exposure estimates, and associations between the estimated exposures and health effects. Median distances between coordinates estimated using the building matching and the three interpolation techniques were 26.4, 27.9, and 35.6 m. Compared with exposure estimates based on building matching, PM10 concentrations based on the three interpolation techniques tended to be overestimated. When building matching was used to estimate exposures, a one-interquartile range increase in PM10 (3.0 μg/m3) was associated with a 3.72-point decrease in FVC% predicted (95% CI: -0.56, -6.88) and a 3.86-point decrease in FEV1% predicted (95% CI: -0.14, -3.24). The magnitude of associations decreased when other geocoding approaches were used [e.g., for FVC% predicted -2.81 (95% CI: -0.26, -5.35) using NavTEQ, or 2.08 (95% CI -4.63, 0.47, p = 0.11) using Google Maps]. Our findings suggest that the choice of geocoding technique may influence estimated health effects when air pollution exposures are estimated using a fine-scale exposure model.

  6. Arsenic in North Carolina: public health implications.

    PubMed

    Sanders, Alison P; Messier, Kyle P; Shehee, Mina; Rudo, Kenneth; Serre, Marc L; Fry, Rebecca C

    2012-01-01

    Arsenic is a known human carcinogen and relevant environmental contaminant in drinking water systems. We set out to comprehensively examine statewide arsenic trends and identify areas of public health concern. Specifically, arsenic trends in North Carolina private wells were evaluated over an eleven-year period using the North Carolina Department of Health and Human Services database for private domestic well waters. We geocoded over 63,000 domestic well measurements by applying a novel geocoding algorithm and error validation scheme. Arsenic measurements and geographical coordinates for database entries were mapped using Geographic Information System techniques. Furthermore, we employed a Bayesian Maximum Entropy (BME) geostatistical framework, which accounts for geocoding error to better estimate arsenic values across the state and identify trends for unmonitored locations. Of the approximately 63,000 monitored wells, 7712 showed detectable arsenic concentrations that ranged between 1 and 806μg/L. Additionally, 1436 well samples exceeded the EPA drinking water standard. We reveal counties of concern and demonstrate a historical pattern of elevated arsenic in some counties, particularly those located along the Carolina terrane (Carolina slate belt). We analyzed these data in the context of populations using private well water and identify counties for targeted monitoring, such as Stanly and Union Counties. By spatiotemporally mapping these data, our BME estimate revealed arsenic trends at unmonitored locations within counties and better predicted well concentrations when compared to the classical kriging method. This study reveals relevant information on the location of arsenic-contaminated private domestic wells in North Carolina and indicates potential areas at increased risk for adverse health outcomes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Arsenic in North Carolina: Public Health Implications

    PubMed Central

    Sanders, Alison P.; Messier, Kyle P.; Shehee, Mina; Rudo, Kenneth; Serre, Marc L.; Fry, Rebecca C.

    2012-01-01

    Arsenic is a known human carcinogen and relevant environmental contaminant in drinking water systems. We set out to comprehensively examine statewide arsenic trends and identify areas of public health concern. Specifically, arsenic trends in North Carolina private wells were evaluated over an eleven-year period using the North Carolina Department of Health and Human Services (NCDHHS) database for private domestic well waters. We geocoded over 63,000 domestic well measurements by applying a novel geocoding algorithm and error validation scheme. Arsenic measurements and geographical coordinates for database entries were mapped using Geographic Information System (GIS) techniques. Furthermore, we employed a Bayesian Maximum Entropy (BME) geostatistical framework, which accounts for geocoding error to better estimate arsenic values across the state and identify trends for unmonitored locations. Of the approximately 63,000 monitored wells, 7,712 showed detectable arsenic concentrations that ranged between 1 and 806 μg/L. Additionally, 1,436 well samples exceeded the EPA drinking water standard. We reveal counties of concern and demonstrate a historical pattern of elevated arsenic in some counties, particularly those located along the Carolina terrane (Carolina slate belt). We analyzed these data in the context of populations using private well water and identify counties for targeted monitoring, such as Stanly and Union Counties. By spatiotemporally mapping these data, our BME estimate revealed arsenic trends at unmonitored locations within counties and better predicted well concentrations when compared to the classical kriging method. This study reveals relevant information on the location of arsenic-contaminated private domestic wells in North Carolina and indicates potential areas at increased risk for adverse health outcomes. PMID:21982028

  8. An analysis of the process and results of manual geocode correction

    PubMed Central

    McDonald, Yolanda J.; Schwind, Michael; Goldberg, Daniel W.; Lampley, Amanda; Wheeler, Cosette M.

    2018-01-01

    Geocoding is the science and process of assigning geographical coordinates (i.e. latitude, longitude) to a postal address. The quality of the geocode can vary dramatically depending on several variables, including incorrect input address data, missing address components, and spelling mistakes. A dataset with a considerable number of geocoding inaccuracies can potentially result in an imprecise analysis and invalid conclusions. There has been little quantitative analysis of the amount of effort (i.e. time) to perform geocoding correction, and how such correction could improve geocode quality type. This study used a low-cost and easy to implement method to improve geocode quality type of an input database (i.e. addresses to be matched) through the processes of manual geocode intervention, and it assessed the amount of effort to manually correct inaccurate geocodes, reported the resulting match rate improvement between the original and the corrected geocodes, and documented the corresponding spatial shift by geocode quality type resulting from the corrections. Findings demonstrated that manual intervention of geocoding resulted in a 90% improvement of geocode quality type, took 42 hours to process, and the spatial shift ranged from 0.02 to 151,368 m. This study provides evidence to inform research teams considering the application of manual geocoding intervention that it is a low-cost and relatively easy process to execute. PMID:28555477

  9. Highway proximity associated with cardiovascular disease risk: the influence of individual-level confounders and exposure misclassification

    PubMed Central

    2013-01-01

    Background Elevated cardiovascular disease risk has been reported with proximity to highways or busy roadways, but proximity measures can be challenging to interpret given potential confounders and exposure error. Methods We conducted a cross sectional analysis of plasma levels of C-Reactive Protein (hsCRP), Interleukin-6 (IL-6), Tumor Necrosis Factor alpha receptor II (TNF-RII) and fibrinogen with distance of residence to a highway in and around Boston, Massachusetts. Distance was assigned using ortho-photo corrected parcel matching, as well as less precise approaches such as simple parcel matching and geocoding addresses to street networks. We used a combined random and convenience sample of 260 adults >40 years old. We screened a large number of individual-level variables including some infrequently collected for assessment of highway proximity, and included a subset in our final regression models. We monitored ultrafine particle (UFP) levels in the study areas to help interpret proximity measures. Results Using the orthophoto corrected geocoding, in a fully adjusted model, hsCRP and IL-6 differed by distance category relative to urban background: 43% (-16%,141%) and 49% (6%,110%) increase for 0-50 m; 7% (-39%,45%) and 41% (6%,86%) for 50-150 m; 54% (-2%,142%) and 18% (-11%,57%) for 150-250 m, and 49% (-4%, 131%) and 42% (6%, 89%) for 250-450 m. There was little evidence for association for TNF-RII or fibrinogen. Ortho-photo corrected geocoding resulted in stronger associations than traditional methods which introduced differential misclassification. Restricted analysis found the effect of proximity on biomarkers was mostly downwind from the highway or upwind where there was considerable local street traffic, consistent with patterns of monitored UFP levels. Conclusion We found associations between highway proximity and both hsCRP and IL-6, with non-monotonic patterns explained partly by individual-level factors and differences between proximity and UFP concentrations. Our analyses emphasize the importance of controlling for the risk of differential exposure misclassification from geocoding error. PMID:24090339

  10. Highway proximity associated with cardiovascular disease risk: the influence of individual-level confounders and exposure misclassification.

    PubMed

    Brugge, Doug; Lane, Kevin; Padró-Martínez, Luz T; Stewart, Andrea; Hoesterey, Kyle; Weiss, David; Wang, Ding Ding; Levy, Jonathan I; Patton, Allison P; Zamore, Wig; Mwamburi, Mkaya

    2013-10-03

    Elevated cardiovascular disease risk has been reported with proximity to highways or busy roadways, but proximity measures can be challenging to interpret given potential confounders and exposure error. We conducted a cross sectional analysis of plasma levels of C-Reactive Protein (hsCRP), Interleukin-6 (IL-6), Tumor Necrosis Factor alpha receptor II (TNF-RII) and fibrinogen with distance of residence to a highway in and around Boston, Massachusetts. Distance was assigned using ortho-photo corrected parcel matching, as well as less precise approaches such as simple parcel matching and geocoding addresses to street networks. We used a combined random and convenience sample of 260 adults >40 years old. We screened a large number of individual-level variables including some infrequently collected for assessment of highway proximity, and included a subset in our final regression models. We monitored ultrafine particle (UFP) levels in the study areas to help interpret proximity measures. Using the orthophoto corrected geocoding, in a fully adjusted model, hsCRP and IL-6 differed by distance category relative to urban background: 43% (-16%,141%) and 49% (6%,110%) increase for 0-50 m; 7% (-39%,45%) and 41% (6%,86%) for 50-150 m; 54% (-2%,142%) and 18% (-11%,57%) for 150-250 m, and 49% (-4%, 131%) and 42% (6%, 89%) for 250-450 m. There was little evidence for association for TNF-RII or fibrinogen. Ortho-photo corrected geocoding resulted in stronger associations than traditional methods which introduced differential misclassification. Restricted analysis found the effect of proximity on biomarkers was mostly downwind from the highway or upwind where there was considerable local street traffic, consistent with patterns of monitored UFP levels. We found associations between highway proximity and both hsCRP and IL-6, with non-monotonic patterns explained partly by individual-level factors and differences between proximity and UFP concentrations. Our analyses emphasize the importance of controlling for the risk of differential exposure misclassification from geocoding error.

  11. Impact of Geocoding Methods on Associations between Long-term Exposure to Urban Air Pollution and Lung Function

    PubMed Central

    Jacquemin, Bénédicte; Lepeule, Johanna; Boudier, Anne; Arnould, Caroline; Benmerad, Meriem; Chappaz, Claire; Ferran, Joane; Kauffmann, Francine; Morelli, Xavier; Pin, Isabelle; Pison, Christophe; Rios, Isabelle; Temam, Sofia; Künzli, Nino; Slama, Rémy

    2013-01-01

    Background: Errors in address geocodes may affect estimates of the effects of air pollution on health. Objective: We investigated the impact of four geocoding techniques on the association between urban air pollution estimated with a fine-scale (10 m × 10 m) dispersion model and lung function in adults. Methods: We measured forced expiratory volume in 1 sec (FEV1) and forced vital capacity (FVC) in 354 adult residents of Grenoble, France, who were participants in two well-characterized studies, the Epidemiological Study on the Genetics and Environment on Asthma (EGEA) and the European Community Respiratory Health Survey (ECRHS). Home addresses were geocoded using individual building matching as the reference approach and three spatial interpolation approaches. We used a dispersion model to estimate mean PM10 and nitrogen dioxide concentrations at each participant’s address during the 12 months preceding their lung function measurements. Associations between exposures and lung function parameters were adjusted for individual confounders and same-day exposure to air pollutants. The geocoding techniques were compared with regard to geographical distances between coordinates, exposure estimates, and associations between the estimated exposures and health effects. Results: Median distances between coordinates estimated using the building matching and the three interpolation techniques were 26.4, 27.9, and 35.6 m. Compared with exposure estimates based on building matching, PM10 concentrations based on the three interpolation techniques tended to be overestimated. When building matching was used to estimate exposures, a one-interquartile range increase in PM10 (3.0 μg/m3) was associated with a 3.72-point decrease in FVC% predicted (95% CI: –0.56, –6.88) and a 3.86-point decrease in FEV1% predicted (95% CI: –0.14, –3.24). The magnitude of associations decreased when other geocoding approaches were used [e.g., for FVC% predicted –2.81 (95% CI: –0.26, –5.35) using NavTEQ, or 2.08 (95% CI –4.63, 0.47, p = 0.11) using Google Maps]. Conclusions: Our findings suggest that the choice of geocoding technique may influence estimated health effects when air pollution exposures are estimated using a fine-scale exposure model. Citation: Jacquemin B, Lepeule J, Boudier A, Arnould C, Benmerad M, Chappaz C, Ferran J, Kauffmann F, Morelli X, Pin I, Pison C, Rios I, Temam S, Künzli N, Slama R, Siroux V. 2013. Impact of geocoding methods on associations between long-term exposure to urban air pollution and lung function. Environ Health Perspect 121:1054–1060; http://dx.doi.org/10.1289/ehp.1206016 PMID:23823697

  12. Geographic Variability in Geocoding Success for West Nile Virus Cases in South Dakota

    PubMed Central

    Wey, Christine L.; Griesse, Jennifer; Kightlinger, Lon; Wimberly, Michael C.

    2009-01-01

    Background Geocoding, the process of assigning each case a set of coordinates that closely approximates its true location, is an important component of spatial epidemiological studies. The failure to accurately geocode cases adversely affects the validity and strength of conclusions drawn from the analysis. We investigated whether there were differences among geographic locations and demographic classes in the ability to successfully geocode West Nile virus (WNV) cases in South Dakota. We successfully geocoded 1,354 cases (80.8%) to their street address locations and assigned all 1,676 cases to ZIP code tabulation areas (ZCTAs). Using spatial scan statistics, significant clusters of non-geocoded cases were identified in central and western South Dakota. Geocoding success rates were lower in areas of low population density and on Indian reservations than in other portions of the state. Geocoding success rates were lower for Native Americans than for other races. Spatial epidemiological studies should consider the potential biases that may result from excluding non-geocoded cases, particularly in rural portions of the Great Plains that contain large Native American populations. PMID:19577505

  13. Accuracy of commercial geocoding: assessment and implications.

    PubMed

    Whitsel, Eric A; Quibrera, P Miguel; Smith, Richard L; Catellier, Diane J; Liao, Duanping; Henley, Amanda C; Heiss, Gerardo

    2006-07-20

    Published studies of geocoding accuracy often focus on a single geographic area, address source or vendor, do not adjust accuracy measures for address characteristics, and do not examine effects of inaccuracy on exposure measures. We addressed these issues in a Women's Health Initiative ancillary study, the Environmental Epidemiology of Arrhythmogenesis in WHI. Addresses in 49 U.S. states (n = 3,615) with established coordinates were geocoded by four vendors (A-D). There were important differences among vendors in address match rate (98%; 82%; 81%; 30%), concordance between established and vendor-assigned census tracts (85%; 88%; 87%; 98%) and distance between established and vendor-assigned coordinates (mean rho [meters]: 1809; 748; 704; 228). Mean rho was lowest among street-matched, complete, zip-coded, unedited and urban addresses, and addresses with North American Datum of 1983 or World Geodetic System of 1984 coordinates. In mixed models restricted to vendors with minimally acceptable match rates (A-C) and adjusted for address characteristics, within-address correlation, and among-vendor heteroscedasticity of rho, differences in mean rho were small for street-type matches (280; 268; 275), i.e. likely to bias results relying on them about equally for most applications. In contrast, differences between centroid-type matches were substantial in some vendor contrasts, but not others (5497; 4303; 4210) p(interaction) < 10(-4), i.e. more likely to bias results differently in many applications. The adjusted odds of an address match was higher for vendor A versus C (odds ratio = 66, 95% confidence interval: 47, 93), but not B versus C (OR = 1.1, 95% CI: 0.9, 1.3). That of census tract concordance was no higher for vendor A versus C (OR = 1.0, 95% CI: 0.9, 1.2) or B versus C (OR = 1.1, 95% CI: 0.9, 1.3). Misclassification of a related exposure measure--distance to the nearest highway--increased with mean rho and in the absence of confounding, non-differential misclassification of this distance biased its hypothetical association with coronary heart disease mortality toward the null. Geocoding error depends on measures used to evaluate it, address characteristics and vendor. Vendor selection presents a trade-off between potential for missing data and error in estimating spatially defined attributes. Informed selection is needed to control the trade-off and adjust analyses for its effects.

  14. Accuracy of commercial geocoding: assessment and implications

    PubMed Central

    Whitsel, Eric A; Quibrera, P Miguel; Smith, Richard L; Catellier, Diane J; Liao, Duanping; Henley, Amanda C; Heiss, Gerardo

    2006-01-01

    Background Published studies of geocoding accuracy often focus on a single geographic area, address source or vendor, do not adjust accuracy measures for address characteristics, and do not examine effects of inaccuracy on exposure measures. We addressed these issues in a Women's Health Initiative ancillary study, the Environmental Epidemiology of Arrhythmogenesis in WHI. Results Addresses in 49 U.S. states (n = 3,615) with established coordinates were geocoded by four vendors (A-D). There were important differences among vendors in address match rate (98%; 82%; 81%; 30%), concordance between established and vendor-assigned census tracts (85%; 88%; 87%; 98%) and distance between established and vendor-assigned coordinates (mean ρ [meters]: 1809; 748; 704; 228). Mean ρ was lowest among street-matched, complete, zip-coded, unedited and urban addresses, and addresses with North American Datum of 1983 or World Geodetic System of 1984 coordinates. In mixed models restricted to vendors with minimally acceptable match rates (A-C) and adjusted for address characteristics, within-address correlation, and among-vendor heteroscedasticity of ρ, differences in mean ρ were small for street-type matches (280; 268; 275), i.e. likely to bias results relying on them about equally for most applications. In contrast, differences between centroid-type matches were substantial in some vendor contrasts, but not others (5497; 4303; 4210) pinteraction < 10-4, i.e. more likely to bias results differently in many applications. The adjusted odds of an address match was higher for vendor A versus C (odds ratio = 66, 95% confidence interval: 47, 93), but not B versus C (OR = 1.1, 95% CI: 0.9, 1.3). That of census tract concordance was no higher for vendor A versus C (OR = 1.0, 95% CI: 0.9, 1.2) or B versus C (OR = 1.1, 95% CI: 0.9, 1.3). Misclassification of a related exposure measure – distance to the nearest highway – increased with mean ρ and in the absence of confounding, non-differential misclassification of this distance biased its hypothetical association with coronary heart disease mortality toward the null. Conclusion Geocoding error depends on measures used to evaluate it, address characteristics and vendor. Vendor selection presents a trade-off between potential for missing data and error in estimating spatially defined attributes. Informed selection is needed to control the trade-off and adjust analyses for its effects. PMID:16857050

  15. Microenvironment Tracker (MicroTrac) | Science Inventory ...

    EPA Pesticide Factsheets

    Epidemiologic studies have shown associations between air pollution concentrations measured at central-site ambient monitors and adverse health outcomes. Using central-site concentrations as exposure surrogates, however, can lead to exposure errors due to time spent in various indoor and outdoor microenvironments (ME) with pollutant concentrations that can be substantially different from central-site concentrations. These exposure errors can introduce bias and incorrect confidence intervals in health effect estimates, which diminish the power of such studies to establish correct conclusions about the exposure and health effects association. The significance of this issue was highlighted in the National Research Council (NRC) Report “Research Priorities for Airborne Particulate Matter”, which recommends that EPA address exposure error in health studies. To address this limitation, we developed MicroTrac, an automated classification model that estimates time of day and duration spent in eight ME (indoors and outdoors at home, work, school; inside vehicles; other locations) from personal global positioning system (GPS) data and geocoded boundaries of buildings (e.g., home, work, school). MicroTrac has several innovative design features: (1) using GPS signal quality to account for GPS signal loss inside certain buildings, (2) spatial buffering of building boundaries to account for the spatial inaccuracy of the GPS device, and (3) temporal buffering of GPS positi

  16. CASE-CONTROL STUDY OF AIR QUALITY AND BIRTH DEFECTS: COMPARISON OF GEOCODED AND NON-GEOCODED POPULATIONS

    EPA Science Inventory

    Unbiased geocoding of maternal residence is critical to the success of an ongoing case-control study of exposure to five criteria air pollutants and the risk of selected birth defects in seven Texas counties between 1997 and 2000. The geocoded residence at delivery will be used ...

  17. The Application of Geocoded Data to Educational Problems.

    ERIC Educational Resources Information Center

    McIsaac, Donald N.; And Others

    The papers presented at a symposium on geocoding describe the preparation of a geocoded data file, some basic applications for education planning, and its use in trend analysis to produce contour maps for any desired characteristic. Geocoding data involves locating each entity, such as students or schools, in terms of grid coordinates on a…

  18. Survey of National Geocoding Systems

    DOT National Transportation Integrated Search

    1974-01-01

    The document describes major geocoding systems. It is organized into sections that categorize geocoding systems by type. Section 2 deals with systems that are primarily geopolitical in nature and provide general reference coding structures for admini...

  19. An earth remote sensing satellite- 1 Synthetic Aperture Radar Mosaic of the Tanana River Basin in Alaska

    USGS Publications Warehouse

    Wivell, Charles E.; Olmsted, Coert; Steinwand, Daniel R.; Taylor, Christopher

    1993-01-01

    Because the pixel location in a line of Synthetic Aperture Radar (SAR) image data is directly related to the distance the pixel is from the radar, terrain elevations cause large displacement errors in the geo-referenced location of the pixel. This is especially true for radar systems with small angles between the nadir and look vectors. Thus, to geo-register a SAR image accurately, the terrain of the area must be taken into account. (Curlander et al., 1987; Kwok et al., 1987, Schreier et al., 1990; Wivell et al., 1992). As part of the 1992 National Aeronautics and Space Administration's Earth Observing System Version 0 activities, a prototype SAR geocod-. ing and terrain correction system was developed at the US. Geological Survey's (USGS) E~os Data Center (EDC) in Sioux Falls, South Dakota. Using this system with 3-arc-second digital elevation models (DEMs) mosaicked at the ED^ Alaska Field Office, 21 ERS-I s.4~ scenes acquired at the Alaska SAR Facility were automatically geocoded, terrain corrected, and mosaicked. The geo-registered scenes were mosaicked using a simple concatenation.

  20. Applications of Geocoding and Mapping.

    ERIC Educational Resources Information Center

    Costa, Crist H.

    The application of computer programing to construction of maps and geographic distributions of data has been called geocoding. This new use of the computer allows much more rapid analysis of various demographic characteristics. In particular, this paper describes the use of computer geocoding in the development of a plot of student density in…

  1. COMPARISON OF GEOCODING METHODS USED IN CASE-CONTROL STUDY OF AIR QUALITY AND BIRTH DEFECTS

    EPA Science Inventory

    Introduction: Accurate geocoding of maternal residence is critical to the success of an ongoing case-control study of exposure to five criteria air pollutants and the risk of selected birth defects in seven Texas counties between 1997 and 2000. The geocoded maternal residence a...

  2. Geocoded data structures and their applications to Earth science investigations

    NASA Technical Reports Server (NTRS)

    Goldberg, M.

    1984-01-01

    A geocoded data structure is a means for digitally representing a geographically referenced map or image. The characteristics of representative cellular, linked, and hybrid geocoded data structures are reviewed. The data processing requirements of Earth science projects at the Goddard Space Flight Center and the basic tools of geographic data processing are described. Specific ways that new geocoded data structures can be used to adapt these tools to scientists' needs are presented. These include: expanding analysis and modeling capabilities; simplifying the merging of data sets from diverse sources; and saving computer storage space.

  3. RELIANCE ON GEOCODED MATERNAL RESIDENCE: IMPACT ON A POPULATION-BASED CASE-CONTROL STUDY OF AIR QUALITY AND BIRTH DEFECTS

    EPA Science Inventory

    Introduction: Unbiased geocoding of maternal residence is critical to the success of an ongoing population-based case-control study of exposure to five criteria air pollutants and the risk of selected birth defects in seven Texas counties between 1997 and 2000. The geocoded res...

  4. Geocoding health data with Geographic Information Systems: a pilot study in northeast Italy for developing a standardized data-acquiring format.

    PubMed

    Baldovin, T; Zangrando, D; Casale, P; Ferrarese, F; Bertoncello, C; Buja, A; Marcolongo, A; Baldo, V

    2015-08-05

    Geographic Information Systems (GIS) have become an innovative and somewhat crucial tool for analyzing relationships between public health data and environment. This study, though focusing on a Local Health Unit of northeastern Italy, could be taken as a benchmark for developing a standardized national data-acquiring format, providing a step-by-step instructions on the manipulation of address elements specific for Italian language and traditions. Geocoding analysis was carried out on a health database comprising 268,517 records of the Local Health Unit of Rovigo in the Veneto region, covering a period of 10 years, starting from 2001 up to 2010. The Map Service provided by the Environmental Research System Institute (ESRI, Redlands, CA), and ArcMap 10.0 by ESRI(®) were, respectively, the reference data and the GIS software, employed in the geocoding process. The first attempt of geocoding produced a poor quality result, having about 40% of the addresses matched. A procedure of manual standardization was performed in order to enhance the quality of the results, consequently a set of guiding principle were expounded which should be pursued for geocoding health data. High-level geocoding detail will provide a more precise geographic representation of health related events. The main achievement of this study was to outline some of the difficulties encountered during the geocoding of health data and to put forward a set of guidelines, which could be useful to facilitate the process and enhance the quality of the results. Public health informatics represents an emerging specialty that highlights on the application of information science and technology to public health practice and research. Therefore, this study could draw the attention of the National Health Service to the underestimated problem of geocoding accuracy in health related data for environmental risk assessment. © Copyright by Pacini Editore SpA, Pisa, Italy.

  5. Geocoding and social marketing in Alabama's cancer prevention programs.

    PubMed

    Miner, Julianna W; White, Arica; Lubenow, Anne E; Palmer, Sally

    2005-11-01

    The Alabama Department of Public Health (ADPH) is collaborating with the National Cancer Institute to develop detailed profiles of underserved Alabama communities most at risk for cancer. These profiles will be combined with geocoded data to create a pilot project, Cancer Prevention for Alabama's Underserved Populations: A Focused Approach. The project's objectives are to provide the ADPH's cancer prevention programs with a more accurate and cost-effective means of planning, implementing, and evaluating its prevention activities in an outcomes-oriented and population-appropriate manner. The project links geocoded data from the Alabama Statewide Cancer Registry with profiles generated by the National Cancer Institute's cancer profiling system, Consumer Health Profiles. These profiles have been successfully applied to market-focused cancer prevention messages across the United States. The ADPH and the National Cancer Institute will evaluate the efficacy of using geocoded data and lifestyle segmentation information in strategy development and program implementation. Alabama is the first state in the nation not only to link geocoded cancer registry data with lifestyle segmentation data but also to use the National Cancer Institute's profiles and methodology in combination with actual state data.

  6. Using Geocoded Databases in Teaching Urban Historical Geography.

    ERIC Educational Resources Information Center

    Miller, Roger P.

    1986-01-01

    Provides information regarding hardware and software requirements for using geocoded databases in urban historical geography. Reviews 11 IBM and Apple Macintosh database programs and describes the pen plotter and digitizing table interface used with the databases. (JDH)

  7. Promoting the Positive Development of Boys in High-Poverty Neighborhoods: Evidence from Four Anti-Poverty Experiments

    ERIC Educational Resources Information Center

    Snell, Emily K.; Castells, Nina; Duncan, Greg; Gennetian, Lisa; Magnuson, Katherine; Morris, Pamela

    2013-01-01

    This study uses geocoded address data and information about parents' economic behavior and children's development from four random-assignment welfare and anti-poverty experiments conducted during the 1990s. We find that the impacts of these welfare and anti-poverty programs on boys' and girls' developmental outcomes during the transition to early…

  8. Geocoding uncertainty analysis for the automated processing of Sentinel-1 data using Sentinel-1 Toolbox software

    NASA Astrophysics Data System (ADS)

    Dostálová, Alena; Naeimi, Vahid; Wagner, Wolfgang; Elefante, Stefano; Cao, Senmao; Persson, Henrik

    2016-10-01

    One of the major advantages of the Sentinel-1 data is its capability to provide very high spatio-temporal coverage allowing the mapping of large areas as well as creation of dense time-series of the Sentinel-1 acquisitions. The SGRT software developed at TU Wien aims at automated processing of Sentinel-1 data for global and regional products. The first step of the processing consists of the Sentinel-1 data geocoding with the help of S1TBX software and their resampling to a common grid. These resampled images serve as an input for the product derivation. Thus, it is very important to select the most reliable processing settings and assess the geocoding uncertainty for both backscatter and projected local incidence angle images. Within this study, selection of Sentinel-1 acquisitions over 3 test areas in Europe were processed manually in the S1TBX software, testing multiple software versions, processing settings and digital elevation models (DEM) and the accuracy of the resulting geocoded images were assessed. Secondly, all available Sentinel-1 data over the areas were processed using selected settings and detailed quality check was performed. Overall, strong influence of the used DEM on the geocoding quality was confirmed with differences up to 80 meters in areas with higher terrain variations. In flat areas, the geocoding accuracy of backscatter images was overall good, with observed shifts between 0 and 30m. Larger systematic shifts were identified in case of projected local incidence angle images. These results encourage the automated processing of large volumes of Sentinel-1 data.

  9. New Jersey Crash Record Geocoding : Improving the State's Crash Database to Enhance Data‐Driven Decisions

    DOT National Transportation Integrated Search

    2010-06-01

    The New Jersey Crash Record Geocoding Initiative was designed as a provisional measure to address missing crash locations. The purpose of the initiative was twofold. Primarily, students worked to locate crashes that had no location information after ...

  10. A geo-coded inventory of anophelines in the Afrotropical Region south of the Sahara: 1898-2016.

    PubMed

    Kyalo, David; Amratia, Punam; Mundia, Clara W; Mbogo, Charles M; Coetzee, Maureen; Snow, Robert W

    2017-01-01

    Background : Understanding the distribution of anopheline vectors of malaria is an important prelude to the design of national malaria control and elimination programmes. A single, geo-coded continental inventory of anophelines using all available published and unpublished data has not been undertaken since the 1960s. Methods : We have searched African, European and World Health Organization archives to identify unpublished reports on anopheline surveys in 48 sub-Saharan Africa countries. This search was supplemented by identification of reports that formed part of post-graduate theses, conference abstracts, regional insecticide resistance databases and more traditional bibliographic searches of peer-reviewed literature. Finally, a check was made against two recent repositories of dominant malaria vector species locations ( circa 2,500). Each report was used to extract information on the survey dates, village locations (geo-coded to provide a longitude and latitude), sampling methods, species identification methods and all anopheline species found present during the survey. Survey records were collapsed to a single site over time.    Results : The search strategy took years and resulted in 13,331 unique, geo-coded survey locations of anopheline vector occurrence between 1898 and 2016. A total of 12,204 (92%) sites reported the presence of 10 dominant vector species/sibling species; 4,473 (37%) of these sites were sampled since 2005. 4,442 (33%) sites reported at least one of 13 possible secondary vector species; 1,107 (25%) of these sites were sampled since 2005. Distributions of dominant and secondary vectors conform to previous descriptions of the ecological ranges of these vectors. Conclusion : We have assembled the largest ever geo-coded database of anophelines in Africa, representing a legacy dataset for future updating and identification of knowledge gaps at national levels. The geo-coded database is available on Harvard Dataverse as a reference source for African national malaria control programmes planning their future control and elimination strategies.

  11. A geo-coded inventory of anophelines in the Afrotropical Region south of the Sahara: 1898-2016

    PubMed Central

    Kyalo, David; Amratia, Punam; Mundia, Clara W.; Mbogo, Charles M.; Coetzee, Maureen; Snow, Robert W.

    2017-01-01

    Background: Understanding the distribution of anopheline vectors of malaria is an important prelude to the design of national malaria control and elimination programmes. A single, geo-coded continental inventory of anophelines using all available published and unpublished data has not been undertaken since the 1960s. Methods: We have searched African, European and World Health Organization archives to identify unpublished reports on anopheline surveys in 48 sub-Saharan Africa countries. This search was supplemented by identification of reports that formed part of post-graduate theses, conference abstracts, regional insecticide resistance databases and more traditional bibliographic searches of peer-reviewed literature. Finally, a check was made against two recent repositories of dominant malaria vector species locations ( circa 2,500). Each report was used to extract information on the survey dates, village locations (geo-coded to provide a longitude and latitude), sampling methods, species identification methods and all anopheline species found present during the survey. Survey records were collapsed to a single site over time.    Results: The search strategy took years and resulted in 13,331 unique, geo-coded survey locations of anopheline vector occurrence between 1898 and 2016. A total of 12,204 (92%) sites reported the presence of 10 dominant vector species/sibling species; 4,473 (37%) of these sites were sampled since 2005. 4,442 (33%) sites reported at least one of 13 possible secondary vector species; 1,107 (25%) of these sites were sampled since 2005. Distributions of dominant and secondary vectors conform to previous descriptions of the ecological ranges of these vectors. Conclusion: We have assembled the largest ever geo-coded database of anophelines in Africa, representing a legacy dataset for future updating and identification of knowledge gaps at national levels. The geo-coded database is available on Harvard Dataverse as a reference source for African national malaria control programmes planning their future control and elimination strategies. PMID:28884158

  12. Teaching Ethics When Working with Geocoded Data: A Novel Experiential Learning Approach

    ERIC Educational Resources Information Center

    van den Bemt, Vera; Doornbos, Julia; Meijering, Louise; Plegt, Marion; Theunissen, Nicky

    2018-01-01

    Research ethics are not the favourite subject of most undergraduate geography students. However, in the light of increasing mixed-methods research, as well as research using geocodes, it is necessary to train students in the field of ethics. Experiential learning is an approach to teaching that is potentially suitable for teaching ethics. The aim…

  13. Ensuring Confidentiality of Geocoded Health Data: Assessing Geographic Masking Strategies for Individual-Level Data.

    PubMed

    Zandbergen, Paul A

    2014-01-01

    Public health datasets increasingly use geographic identifiers such as an individual's address. Geocoding these addresses often provides new insights since it becomes possible to examine spatial patterns and associations. Address information is typically considered confidential and is therefore not released or shared with others. Publishing maps with the locations of individuals, however, may also breach confidentiality since addresses and associated identities can be discovered through reverse geocoding. One commonly used technique to protect confidentiality when releasing individual-level geocoded data is geographic masking. This typically consists of applying a certain amount of random perturbation in a systematic manner to reduce the risk of reidentification. A number of geographic masking techniques have been developed as well as methods to quantity the risk of reidentification associated with a particular masking method. This paper presents a review of the current state-of-the-art in geographic masking, summarizing the various methods and their strengths and weaknesses. Despite recent progress, no universally accepted or endorsed geographic masking technique has emerged. Researchers on the other hand are publishing maps using geographic masking of confidential locations. Any researcher publishing such maps is advised to become familiar with the different masking techniques available and their associated reidentification risks.

  14. Ensuring Confidentiality of Geocoded Health Data: Assessing Geographic Masking Strategies for Individual-Level Data

    PubMed Central

    Zandbergen, Paul A.

    2014-01-01

    Public health datasets increasingly use geographic identifiers such as an individual's address. Geocoding these addresses often provides new insights since it becomes possible to examine spatial patterns and associations. Address information is typically considered confidential and is therefore not released or shared with others. Publishing maps with the locations of individuals, however, may also breach confidentiality since addresses and associated identities can be discovered through reverse geocoding. One commonly used technique to protect confidentiality when releasing individual-level geocoded data is geographic masking. This typically consists of applying a certain amount of random perturbation in a systematic manner to reduce the risk of reidentification. A number of geographic masking techniques have been developed as well as methods to quantity the risk of reidentification associated with a particular masking method. This paper presents a review of the current state-of-the-art in geographic masking, summarizing the various methods and their strengths and weaknesses. Despite recent progress, no universally accepted or endorsed geographic masking technique has emerged. Researchers on the other hand are publishing maps using geographic masking of confidential locations. Any researcher publishing such maps is advised to become familiar with the different masking techniques available and their associated reidentification risks. PMID:26556417

  15. Presentation Of The Small Baseline NSBAS Processing Chain On A Case Example: The ETNA Deformation Monitoring From 2003 to 2010 Using ENVISAT Data

    NASA Astrophysics Data System (ADS)

    Doin, Marie-Pierre; Lodge, Felicity; Guillaso, Stephane; Jolivet, Romain; Lasserre, Cecile; Ducret, Gabriel; Grandin, Raphael; Pathier, Erwan; Pinel, Virginie

    2012-01-01

    We assemble a processing chain that handles InSAR computation from raw data to time series analysis. A large part of the chain (from raw data to geocoded unwrapped interferograms) is based on ROI PAC modules (Rosen et al., 2004), with original routines rearranged and combined with new routines to process in series and in a common radar geometry all SAR images and interferograms. A new feature of the software is the range-dependent spectral filtering to improve coherence in interferograms with long spatial baselines. Additional components include a module to estimate and remove digital elevation model errors before unwrapping, a module to mitigate the effects of the atmospheric phase delay and remove residual orbit errors, and a module to construct the phase change time series from small baseline interferograms (Berardino et al. 2002). This paper describes the main elements of the processing chain and presents an example of application of the software using a data set from the ENVISAT mission covering the Etna volcano.

  16. Examining the relationships among built environment, physical activity, and body mass index in El Paso, TX.

    PubMed

    Rutt, Candace D; Coleman, Karen J

    2005-06-01

    The current study examined the relationships among built environment, physical activity, and body mass index (BMI) in a primarily Hispanic border community in El Paso, TX. Data from a 2001 community-wide health survey were matched to environmental data using geocoding techniques in ARC VIEW software. A total of 996 adults were surveyed by phone and 452 were successfully geocoded. The sample was 71% female, 79% Hispanic, 42 +/- 17 years old, moderately acculturated, and had socioeconomic status (SES) levels of semi-skilled workers. Increasing BMI was related to less moderate intensity physical activity (P = 0.05), higher SES (P = 0.0003), worse overall health (P = 0.0004), and living in areas with greater land-use mix (less residential; P = 0.03). The relationship between overall health and BMI was in part mediated by higher numbers of barriers to physical activity in those with poor health, which lead to a decrease in moderate physical activity. These variables explained 20% of the variance in BMI. This is one of the first studies to find a positive relationship between land-use mix and BMI in a predominantly Hispanic, low-income community. The positive association between BMI and land-use mix may be due to the inclusion of individual SES as a controlling variable in the analyses, suggesting that SES may have a differential effect on how the built environment influences BMI in low- to moderate-income minority communities.

  17. The Near-Source Intensity Distribution for the August 24, 2014, South Napa Earthquake

    NASA Astrophysics Data System (ADS)

    Boatwright, J.; Pickering, A.; Blair, J. L.

    2016-12-01

    The 2014 Mw=6.0 South Napa earthquake was the largest and most damaging earthquake to occur in the Bay Area since the 1989 Mw=6.9 Loma Prieta earthquake. The City of Napa estimated that the earthquake caused 300 million damage to homes and commercial properties and 58 million to public infrastructure. Over 41,000 reports were entered on the USGS "Did You Feel It?" (DYFI) website: 730 of these reports were located within 15 km of the rupture. Unfortunately, very few geocoded intensities were obtained immediately west and north of the rupture area. In the weeks following the earthquake, we conducted an intensity survey focused on areas poorly sampled by the DYFI reports. 75 sites were surveyed within 15 km of the earthquake rupture. In addition, we checked and manually geocoded many of the DYFI reports, locating 245 reports within 15 km of the rupture that the automated DYFI processing failed to geocode. We combine the survey sites and the newly geocoded DYFI reports with the original geocoded DYFI reports to map and contour the near-source shaking intensity. In addition to imaging the strong shaking (MMI 7.0-8.0) in the City of Napa, we find an area of very strong shaking (MMI 7.5-8.0) to the northwest of the earthquake rupture. This area, marked by ground cracks, damage to modern wood-frame buildings, and reports of people knocked down, coincides with the directivity expected for rupture to the northwest and up dip. The intensities from the survey sites are consistent with the intensities from the DYFI reports, but are much less variable. For DYFI intensities MMI 4-6, this variability could be derived from the 3:20 AM occurrence of the earthquake: some of the effects that the DYFI questionnaire uses to assign these intensities (objects swaying, bushes and trees shaken) cannot be observed in the dark.

  18. A Framework for Widespread Replication of a Highly Spatially Resolved Childhood Lead Exposure Risk Model

    PubMed Central

    Kim, Dohyeong; Galeano, M. Alicia Overstreet; Hull, Andrew; Miranda, Marie Lynn

    2008-01-01

    Background Preventive approaches to childhood lead poisoning are critical for addressing this longstanding environmental health concern. Moreover, increasing evidence of cognitive effects of blood lead levels < 10 μg/dL highlights the need for improved exposure prevention interventions. Objectives Geographic information system–based childhood lead exposure risk models, especially if executed at highly resolved spatial scales, can help identify children most at risk of lead exposure, as well as prioritize and direct housing and health-protective intervention programs. However, developing highly resolved spatial data requires labor-and time-intensive geocoding and analytical processes. In this study we evaluated the benefit of increased effort spent geocoding in terms of improved performance of lead exposure risk models. Methods We constructed three childhood lead exposure risk models based on established methods but using different levels of geocoded data from blood lead surveillance, county tax assessors, and the 2000 U.S. Census for 18 counties in North Carolina. We used the results to predict lead exposure risk levels mapped at the individual tax parcel unit. Results The models performed well enough to identify high-risk areas for targeted intervention, even with a relatively low level of effort on geocoding. Conclusions This study demonstrates the feasibility of widespread replication of highly spatially resolved childhood lead exposure risk models. The models guide resource-constrained local health and housing departments and community-based organizations on how best to expend their efforts in preventing and mitigating lead exposure risk in their communities. PMID:19079729

  19. A cross-sectional ecological analysis of international and sub-national health inequalities in commercial geospatial resource availability.

    PubMed

    Dotse-Gborgbortsi, Winfred; Wardrop, Nicola; Adewole, Ademola; Thomas, Mair L H; Wright, Jim

    2018-05-23

    Commercial geospatial data resources are frequently used to understand healthcare utilisation. Although there is widespread evidence of a digital divide for other digital resources and infra-structure, it is unclear how commercial geospatial data resources are distributed relative to health need. To examine the distribution of commercial geospatial data resources relative to health needs, we assembled coverage and quality metrics for commercial geocoding, neighbourhood characterisation, and travel time calculation resources for 183 countries. We developed a country-level, composite index of commercial geospatial data quality/availability and examined its distribution relative to age-standardised all-cause and cause specific (for three main causes of death) mortality using two inequality metrics, the slope index of inequality and relative concentration index. In two sub-national case studies, we also examined geocoding success rates versus area deprivation by district in Eastern Region, Ghana and Lagos State, Nigeria. Internationally, commercial geospatial data resources were inversely related to all-cause mortality. This relationship was more pronounced when examining mortality due to communicable diseases. Commercial geospatial data resources for calculating patient travel times were more equitably distributed relative to health need than resources for characterising neighbourhoods or geocoding patient addresses. Countries such as South Africa have comparatively high commercial geospatial data availability despite high mortality, whilst countries such as South Korea have comparatively low data availability and low mortality. Sub-nationally, evidence was mixed as to whether geocoding success was lowest in more deprived districts. To our knowledge, this is the first global analysis of commercial geospatial data resources in relation to health outcomes. In countries such as South Africa where there is high mortality but also comparatively rich commercial geospatial data, these data resources are a potential resource for examining healthcare utilisation that requires further evaluation. In countries such as Sierra Leone where there is high mortality but minimal commercial geospatial data, alternative approaches such as open data use are needed in quantifying patient travel times, geocoding patient addresses, and characterising patients' neighbourhoods.

  20. Small baseline subsets approach of DInSAR for investigating land surface deformation along the high-speed railway

    NASA Astrophysics Data System (ADS)

    Rao, Xiong; Tang, Yunwei

    2014-11-01

    Land surface deformation evidently exists in a newly-built high-speed railway in the southeast of China. In this study, we utilize the Small BAseline Subsets (SBAS)-Differential Synthetic Aperture Radar Interferometry (DInSAR) technique to detect land surface deformation along the railway. In this work, 40 Cosmo-SkyMed satellite images were selected to analyze the spatial distribution and velocity of the deformation in study area. 88 pairs of image with high coherence were firstly chosen with an appropriate threshold. These images were used to deduce the deformation velocity map and the variation in time series. This result can provide information for orbit correctness and ground control point (GCP) selection in the following steps. Then, more pairs of image were selected to tighten the constraint in time dimension, and to improve the final result by decreasing the phase unwrapping error. 171 combinations of SAR pairs were ultimately selected. Reliable GCPs were re-selected according to the previously derived deformation velocity map. Orbital residuals error was rectified using these GCPs, and nonlinear deformation components were estimated. Therefore, a more accurate surface deformation velocity map was produced. Precise geodetic leveling work was implemented in the meantime. We compared the leveling result with the geocoding SBAS product using the nearest neighbour method. The mean error and standard deviation of the error were respectively 0.82 mm and 4.17 mm. This result demonstrates the effectiveness of DInSAR technique for monitoring land surface deformation, which can serve as a reliable decision for supporting highspeed railway project design, construction, operation and maintenance.

  1. AOIPS water resources data management system

    NASA Technical Reports Server (NTRS)

    Merritt, E. S.; Shotwell, R. L.; Place, M. C.; Belknap, N. J.

    1976-01-01

    A geocoded data management system applicable for hydrological applications was designed to demonstrate the utility of the Atmospheric and Oceanographic Information Processing System (AOIPS) for hydrological applications. Within that context, the geocoded hydrology data management system was designed to take advantage of the interactive capability of the AOIPS hardware. Portions of the Water Resource Data Management System which best demonstrate the interactive nature of the hydrology data management system were implemented on the AOIPS. A hydrological case study was prepared using all data supplied for the Bear River watershed located in northwest Utah, southeast Idaho, and western Wyoming.

  2. Promoting the Positive Development of Boys in High-Poverty Neighborhoods: Evidence From Four Anti-Poverty Experiments

    PubMed Central

    Snell, Emily K.; Castells, Nina; Duncan, Greg; Gennetian, Lisa; Magnuson, Katherine; Morris, Pamela

    2012-01-01

    This study uses geocoded address data and information about parent’s economic behavior and children’s development from four random-assignment welfare and anti-poverty experiments conducted during the 1990s. We find that the impacts of these welfare and anti-poverty programs on boys’ and girls’ developmental outcomes during the transition to early adolescence differ as a function of neighborhood poverty levels. The strongest positive impacts of these programs are among boys who lived in high-poverty neighborhoods at the time their parents enrolled in the studies, with smaller or non-statistically significant effects for boys in lower poverty neighborhoods and for girls across all neighborhoods. This research informs our understanding of how neighborhood context and child gender may interact with employment-based policies to affect children’s well-being. PMID:24348000

  3. An image based information system - Architecture for correlating satellite and topological data bases

    NASA Technical Reports Server (NTRS)

    Bryant, N. A.; Zobrist, A. L.

    1978-01-01

    The paper describes the development of an image based information system and its use to process a Landsat thematic map showing land use or land cover in conjunction with a census tract polygon file to produce a tabulation of land use acreages per census tract. The system permits the efficient cross-tabulation of two or more geo-coded data sets, thereby setting the stage for the practical implementation of models of diffusion processes or cellular transformation. Characteristics of geographic information systems are considered, and functional requirements, such as data management, geocoding, image data management, and data analysis are discussed. The system is described, and the potentialities of its use are examined.

  4. Using the Bayesian Improved Surname Geocoding Method (BISG) to create a working classification of race and ethnicity in a diverse managed care population: a validation study.

    PubMed

    Adjaye-Gbewonyo, Dzifa; Bednarczyk, Robert A; Davis, Robert L; Omer, Saad B

    2014-02-01

    To validate classification of race/ethnicity based on the Bayesian Improved Surname Geocoding method (BISG) and assess variations in validity by gender and age. Secondary data on members of Kaiser Permanente Georgia, an integrated managed care organization, through 2010. For 191,494 members with self-reported race/ethnicity, probabilities for belonging to each of six race/ethnicity categories predicted from the BISG algorithm were used to assign individuals to a race/ethnicity category over a range of cutoffs greater than a probability of 0.50. Overall as well as gender- and age-stratified sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Receiver operating characteristic (ROC) curves were generated and used to identify optimal cutoffs for race/ethnicity assignment. The overall cutoffs for assignment that optimized sensitivity and specificity ranged from 0.50 to 0.57 for the four main racial/ethnic categories (White, Black, Asian/Pacific Islander, Hispanic). Corresponding sensitivity, specificity, PPV, and NPV ranged from 64.4 to 81.4 percent, 80.8 to 99.7 percent, 75.0 to 91.6 percent, and 79.4 to 98.0 percent, respectively. Accuracy of assignment was better among males and individuals of 65 years or older. BISG may be useful for classifying race/ethnicity of health plan members when needed for health care studies. © Health Research and Educational Trust.

  5. The use of missing birth record data as a marker for adverse reproductive outcomes: a geocoded analysis of birth record data.

    PubMed Central

    Headley, Adrienne J.; Fulcomer, Mark C.; Bastardi, Matthew M.; Im, Wansoo; Sass, Marcia M.; Chung, Katherine

    2006-01-01

    Adverse reproductive outcomes (AROs) disproportionately affect black American infants and significantly contribute to the U.S. infant mortality rate. Without accurate understanding of AROs, there remains little hope of ameliorating infant mortality rates or eliminating infant health disparities. However, despite the importance of monitoring infant mortality rates and health disparities, birth record data quality is not assured. Racial disparities in the reporting of birth record data have been documented, and missing birth record data for AROs appears to be disproportionate. Due to the extent of missing birth record data, innovative strategies have been developed to evaluate relationships between maternal socioeconomic status (SES) and community-based ARO rates. Because addresses convey aggregate information about income level, education and occupation, ZIP codes, census tracts and census block-groups have been applied to geocoding efforts. The goals of this study are to: 1) analyze the extent of missing birth record data for New Jersey areas with high rates of an ARO (preterm birth), 2) evaluate associations between the extent of missing birth record data and other AROs, and 3) consider how geocoding strategies could be applied to provide a basis for understanding maternal SES risk factors and ARO resource allocation for at-risk communities. PMID:16895276

  6. The spatial accuracy of geographic ecological momentary assessment (GEMA): Error and bias due to subject and environmental characteristics.

    PubMed

    Mennis, Jeremy; Mason, Michael; Ambrus, Andreea; Way, Thomas; Henry, Kevin

    2017-09-01

    Geographic ecological momentary assessment (GEMA) combines ecological momentary assessment (EMA) with global positioning systems (GPS) and geographic information systems (GIS). This study evaluates the spatial accuracy of GEMA location data and bias due to subject and environmental data characteristics. Using data for 72 subjects enrolled in a study of urban adolescent substance use, we compared the GPS-based location of EMA responses in which the subject indicated they were at home to the geocoded home address. We calculated the percentage of EMA locations within a sixteenth, eighth, quarter, and half miles from the home, and the percentage within the same tract and block group as the home. We investigated if the accuracy measures were associated with subject demographics, substance use, and emotional dysregulation, as well as environmental characteristics of the home neighborhood. Half of all subjects had more than 88% of their EMA locations within a half mile, 72% within a quarter mile, 55% within an eighth mile, 50% within a sixteenth of a mile, 83% in the correct tract, and 71% in the correct block group. There were no significant associations with subject or environmental characteristics. Results support the use of GEMA for analyzing subjects' exposures to urban environments. Researchers should be aware of the issue of spatial accuracy inherent in GEMA, and interpret results accordingly. Understanding spatial accuracy is particularly relevant for the development of 'ecological momentary interventions' (EMI), which may depend on accurate location information, though issues of privacy protection remain a concern. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Building-level analyses to prospectively detect influenza outbreaks in long-term care facilities: New York City, 2013-2014.

    PubMed

    Levin-Rector, Alison; Nivin, Beth; Yeung, Alice; Fine, Annie D; Greene, Sharon K

    2015-08-01

    Timely outbreak detection is necessary to successfully control influenza in long-term care facilities (LTCFs) and other institutions. To supplement nosocomial outbreak reports, calls from infection control staff, and active laboratory surveillance, the New York City (NYC) Department of Health and Mental Hygiene implemented an automated building-level analysis to proactively identify LTCFs with laboratory-confirmed influenza activity. Geocoded addresses of LTCFs in NYC were compared with geocoded residential addresses for all case-patients with laboratory-confirmed influenza reported through passive surveillance. An automated daily analysis used the geocoded building identification number, approximate text matching, and key-word searches to identify influenza in residents of LTCFs for review and follow-up by surveillance coordinators. Our aim was to determine whether the building analysis improved prospective outbreak detection during the 2013-2014 influenza season. Of 119 outbreaks identified in LTCFs, 109 (92%) were ever detected by the building analysis, and 55 (46%) were first detected by the building analysis. Of the 5,953 LTCF staff and residents who received antiviral prophylaxis during the 2013-2014 season, 929 (16%) were at LTCFs where outbreaks were initially detected by the building analysis. A novel building-level analysis improved influenza outbreak identification in LTCFs in NYC, prompting timely infection control measures. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Intelligent geocoding system to locate traffic crashes.

    PubMed

    Qin, Xiao; Parker, Steven; Liu, Yi; Graettinger, Andrew J; Forde, Susie

    2013-01-01

    State agencies continue to face many challenges associated with new federal crash safety and highway performance monitoring requirements that use data from multiple and disparate systems across different platforms and locations. On a national level, the federal government has a long-term vision for State Departments of Transportation (DOTs) to report state route and off-state route crash data in a single network. In general, crashes occurring on state-owned or state maintained highways are a priority at the Federal and State level; therefore, state-route crashes are being geocoded by state DOTs. On the other hand, crashes occurring on off-state highway system do not always get geocoded due to limited resources and techniques. Creating and maintaining a statewide crash geographic information systems (GIS) map with state route and non-state route crashes is a complicated and expensive task. This study introduces an automatic crash mapping process, Crash-Mapping Automation Tool (C-MAT), where an algorithm translates location information from a police report crash record to a geospatial map and creates a pinpoint map for all crashes. The algorithm has approximate 83 percent mapping rate. An important application of this work is the ability to associate the mapped crash records to underlying business data, such as roadway inventory and traffic volumes. The integrated crash map is the foundation for effective and efficient crash analyzes to prevent highway crashes. Published by Elsevier Ltd.

  9. Hispanic residential ethnic density and depression in post-acute coronary syndrome patients: Re-thinking the role of social support.

    PubMed

    Denton, Ellen-Ge D; Shaffer, Jonathan A; Alcantara, Carmela; Clemow, Lynn; Brondolo, Elizabeth

    2015-05-01

    The ethnic density hypothesis suggests that ethnic density confers greater social support and consequently protects against depressive symptoms in ethnic minority individuals. However, the potential benefits of ethnic density have not been examined in individuals who are facing a specific and salient life stressor. We examined the degree to which the effects of Hispanic ethnic density on depressive symptoms are explained by socioeconomic resources and social support. Patients with acute coronary syndrome (ACS, N = 472) completed the Beck Depression Inventory (BDI) and measures of demographics, ACS clinical factors and perceived social support. Neighborhood characteristics, including median income, number of single parent households and Hispanic ethnic density, were extracted from the American Community Survey Census (2005-2009) for each patient using his or her geocoded address. In a linear regression analysis adjusted for demographic and clinical factors, Hispanic ethnic density was positively associated with depressive symptoms (β = .09, standard error (SE) = .04, p = .03). However, Hispanic density was no longer a significant predictor of depressive symptoms when neighborhood characteristics were controlled. The relationship of Hispanic density on depressive symptoms was moderated by nativity status. Among US-born patients with ACS, there was a significant positive relationship between Hispanic density and depressive symptoms and social support significantly mediated this effect. There was no observed effect of Hispanic density to depressive symptoms for foreign-born ACS patients. Although previous research suggests that ethnic density may be protective against depression, our data suggest that among patients with ACS, living in a community with a high concentration of Hispanic individuals is associated with constrained social and economic resources that are themselves associated with greater depressive symptoms. These data add to a growing body of literature on the effects of racial or ethnic segregation on health outcomes. © The Author(s) 2014.

  10. Geocoding and stereo display of tropical forest multisensor datasets

    NASA Technical Reports Server (NTRS)

    Welch, R.; Jordan, T. R.; Luvall, J. C.

    1990-01-01

    Concern about the future of tropical forests has led to a demand for geocoded multisensor databases that can be used to assess forest structure, deforestation, thermal response, evapotranspiration, and other parameters linked to climate change. In response to studies being conducted at the Braulino Carrillo National Park, Costa Rica, digital satellite and aircraft images recorded by Landsat TM, SPOT HRV, Thermal Infrared Multispectral Scanner, and Calibrated Airborne Multispectral Scanner sensors were placed in register using the Landsat TM image as the reference map. Despite problems caused by relief, multitemporal datasets, and geometric distortions in the aircraft images, registration was accomplished to within + or - 20 m (+ or - 1 data pixel). A digital elevation model constructed from a multisensor Landsat TM/SPOT stereopair proved useful for generating perspective views of the rugged, forested terrain.

  11. "The Great Transformation" and suicide: local and long-lasting effects of 1930 bank suspensions.

    PubMed

    Baller, Robert D; Levchak, Phil; Schultz, Mark

    2010-12-01

    Depression-era bank suspensions and failures are conceptualized as products of the first part of what Polanyi (1994) called "The Great Transformation," which involved an imbalanced institutional arrangement in which the economy dominated other institutions. Relying on Durkheim (1897/1951) and Merton (1938, 1968), it is argued that these banking problems accentuated the type of chronic anomie that Durkheim theorized would create normative deregulation and elevated suicide rates over the long-term. Results from county-level analyses are supportive as the 1930 bank suspension rate is positively related to the 2000 suicide rate, controlling for contemporary and historical factors. The mediating roles of integration and chronic anomie are considered, with the latter measured using data from the geocoded General Social Survey.

  12. Geocoding of AIRSAR/TOPSAR SAR Data

    NASA Technical Reports Server (NTRS)

    Holecz, Francesco; Lou, Yun-Ling; vanZyl, Jakob

    1996-01-01

    It has been demonstrated and recognized that radar interferometry is a promising method for the determination of digital elevation information and terrain slope from Synthetic Aperture Radar (SAR) data. An important application of Interferometric SAR (InSAR) data in areas with topographic variations is that the derived elevation and slope can be directly used for the absolute radiometric calibration of the amplitude SAR data as well as for scattering mechanisms analysis. On the other hand polarimetric SAR data has long been recognized as permitting a more complete inference of natural surfaces than a single channel radar system. In fact, imaging polarimetry provides the measurement of the amplitude and relative phase of all transmit and receive polarizations. On board the NASA DC-8 aircraft, NASA/JPL operates the multifrequency (P, L and C bands) multipolarimetric radar AIRSAR. The TOPSAR, a special mode of the AIRSAR system, is able to collect single-pass interferometric C- and/or L-band VV polarized data. A possible configuration of the AIRSAR/TOPSAR system is to acquire single-pass interferometric data at C-band VV polarization and polarimetric radar data at the two other lower frequencies. The advantage of this system configuration is to get digital topography information at the same time the radar data is collected. The digital elevation information can therefore be used to correctly calibrate the SAR data. This step is directly included in the new AIRSAR Integrated Processor. This processor uses a modification of the full motion compensation algorithm described by Madsen et al. (1993). However, the Digital Elevation Model (DEM) with the additional products such as local incidence angle map, and the SAR data are in a geometry which is not convenient, since especially DEMs must be referred to a specific cartographic reference system. Furthermore, geocoding of SAR data is important for multisensor and/or multitemporal purposes. In this paper, a procedure to geocode the new AIRSAR/TOPSAR data is presented. As an example an AIRSAR/TOPSAR image acquired in 1994 is geocoded and evaluated in terms of geometric accuracy.

  13. Neighborhood Racial Composition, Racial Discrimination, and Depressive Symptoms in African Americans

    PubMed Central

    Lambert, Sharon F.; Evans, Michele K.; Zonderman, Alan B.

    2015-01-01

    While evidence indicates that experienced racial discrimination is associated with increased depressive symptoms for African Americans, there is little research investigating predictors of experienced racial discrimination. This paper examines neighborhood racial composition and sociodemographic factors as antecedents to experienced racial discrimination and resultant levels of depressive symptoms among African American adults. The sample included 505 socioeconomically-diverse African American adults from Baltimore, MD. Study data were obtained via self-report and geocoding of participant addresses based on 2010 census data. Study hypotheses were tested using multiple pathways within a longitudinal Structural Equation Model. Experienced racial discrimination was positively associated with age and sex such that older individuals and males experienced increased levels of racial discrimination. In addition, the percentage of White individuals residing in a neighborhood was positively associated with levels of experienced racial discrimination for African American neighborhood residents. Experienced racial discrimination was positively associated with later depressive symptoms. Neighborhood-level contextual factors such as neighborhood racial composition and individual differences in sociodemographic characteristics appear to play an important role in the experience of racial discrimination and the etiology of depression in African American adults. PMID:24969707

  14. Neighborhood racial composition, racial discrimination, and depressive symptoms in African Americans.

    PubMed

    English, Devin; Lambert, Sharon F; Evans, Michele K; Zonderman, Alan B

    2014-12-01

    While evidence indicates that experienced racial discrimination is associated with increased depressive symptoms for African Americans, there is little research investigating predictors of experienced racial discrimination. This paper examines neighborhood racial composition and sociodemographic factors as antecedents to experienced racial discrimination and resultant levels of depressive symptoms among African American adults. The sample included 505 socioeconomically-diverse African American adults from Baltimore, MD. Study data were obtained via self-report and geocoding of participant addresses based on 2010 census data. Study hypotheses were tested using multiple pathways within a longitudinal Structural Equation Model. Experienced racial discrimination was positively associated with age and sex such that older individuals and males experienced increased levels of racial discrimination. In addition, the percentage of White individuals residing in a neighborhood was positively associated with levels of experienced racial discrimination for African American neighborhood residents. Experienced racial discrimination was positively associated with later depressive symptoms. Neighborhood-level contextual factors such as neighborhood racial composition and individual differences in sociodemographic characteristics appear to play an important role in the experience of racial discrimination and the etiology of depression in African American adults.

  15. Mapping the Spread of Methamphetamine Abuse in California From 1995 to 2008

    PubMed Central

    Ponicki, William R.; Remer, Lillian G.; Waller, Lance A.; Zhu, Li; Gorman, Dennis M.

    2013-01-01

    Objectives. From 1983 to 2008, the incidence of methamphetamine abuse and dependence (MA) presenting at hospitals in California increased 13-fold. We assessed whether this growth could be characterized as a drug epidemic. Methods. We geocoded MA discharges to residential zip codes from 1995 through 2008. We related discharges to population and environmental characteristics using Bayesian Poisson conditional autoregressive models, correcting for small area effects and spatial misalignment and enabling an assessment of contagion between areas. Results. MA incidence increased exponentially in 3 phases interrupted by implementation of laws limiting access to methamphetamine precursors. MA growth from 1999 through 2008 was 17% per year. MA was greatest in areas with larger White or Hispanic low-income populations, small household sizes, and good connections to highway systems. Spatial misalignment was a source of bias in estimated effects. Spatial autocorrelation was substantial, accounting for approximately 80% of error variance in the model. Conclusions. From 1995 through 2008, MA exhibited signs of growth and spatial spread characteristic of drug epidemics, spreading most rapidly through low-income White and Hispanic populations living outside dense urban areas. PMID:23078474

  16. Health information system strengthening and malaria elimination in Papua New Guinea.

    PubMed

    Rosewell, Alexander; Makita, Leo; Muscatello, David; John, Lucy Ninmongo; Bieb, Sibauk; Hutton, Ross; Ramamurthy, Sundar; Shearman, Phil

    2017-07-05

    The objective of the study was to describe an m-health initiative to strengthen malaria surveillance in a 184-health facility, multi-province, project aimed at strengthening the National Health Information System (NHIS) in a country with fragmented malaria surveillance, striving towards enhanced control, pre-elimination. A remote-loading mobile application and secure online platform for health professionals was created to interface with the new system (eNHIS). A case-based malaria testing register was developed and integrated geo-coded households, villages and health facilities. A malaria programme management dashboard was created, with village-level malaria mapping tools, and statistical algorithms to identify malaria outbreaks. Since its inception in 2015, 160,750 malaria testing records, including village of residence, have been reported to the eNHIS. These case-based, geo-coded malaria data are 100% complete, with a median data entry delay of 9 days from the date of testing. The system maps malaria to the village level in near real-time as well as the availability of treatment and diagnostics to health facility level. Data aggregation, analysis, outbreak detection, and reporting are automated. The study demonstrates that using mobile technologies and GIS in the capture and reporting of NHIS data in Papua New Guinea provides timely, high quality, geo-coded, case-based malaria data required for malaria elimination. The health systems strengthening approach of integrating malaria information management into the eNHIS optimizes sustainability and provides enormous flexibility to cater for future malaria programme needs.

  17. SU-E-T-377: Inaccurate Positioning Might Introduce Significant MapCheck Calibration Error in Flatten Filter Free Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, S; Chao, C; Columbia University, NY, NY

    2014-06-01

    Purpose: This study investigates the calibration error of detector sensitivity for MapCheck due to inaccurate positioning of the device, which is not taken into account by the current commercial iterative calibration algorithm. We hypothesize the calibration is more vulnerable to the positioning error for the flatten filter free (FFF) beams than the conventional flatten filter flattened beams. Methods: MapCheck2 was calibrated with 10MV conventional and FFF beams, with careful alignment and with 1cm positioning error during calibration, respectively. Open fields of 37cmx37cm were delivered to gauge the impact of resultant calibration errors. The local calibration error was modeled as amore » detector independent multiplication factor, with which propagation error was estimated with positioning error from 1mm to 1cm. The calibrated sensitivities, without positioning error, were compared between the conventional and FFF beams to evaluate the dependence on the beam type. Results: The 1cm positioning error leads to 0.39% and 5.24% local calibration error in the conventional and FFF beams respectively. After propagating to the edges of MapCheck, the calibration errors become 6.5% and 57.7%, respectively. The propagation error increases almost linearly with respect to the positioning error. The difference of sensitivities between the conventional and FFF beams was small (0.11 ± 0.49%). Conclusion: The results demonstrate that the positioning error is not handled by the current commercial calibration algorithm of MapCheck. Particularly, the calibration errors for the FFF beams are ~9 times greater than those for the conventional beams with identical positioning error, and a small 1mm positioning error might lead to up to 8% calibration error. Since the sensitivities are only slightly dependent of the beam type and the conventional beam is less affected by the positioning error, it is advisable to cross-check the sensitivities between the conventional and FFF beams to detect potential calibration errors due to inaccurate positioning. This work was partially supported by a DOD Grant No.; DOD W81XWH1010862.« less

  18. National Oceanic and Atmospheric Administration hydrographic survey data used in a U.S. Geological Survey regional geologic framework study along the Delmarva Peninsula

    USGS Publications Warehouse

    Pendleton, Elizabeth A.; Brothers, Laura L.; Thieler, E. Robert; Danforth, William W.; Parker, Castle E.

    2014-01-01

    The U.S. Geological Survey obtained raw Reson multibeam data files from Science Applications International Corporation and the National Oceanic and Atmospheric Administration for 20 hydrographic surveys and extracted backscatter data using the Fledermaus Geocoder Toolbox from Quality Positioning Service. The backscatter mosaics produced by the U.S. Geological Survey for the inner continental shelf of the Delmarva Peninsula using National Oceanic and Atmospheric Administration data increased regional geophysical surveying efficiency, collaboration among government agencies, and the area over which geologic data can be interpreted by the U.S. Geological Survey. This report describes the methods by which the backscatter data were extracted and processed and includes backscatter mosaics and interpolated bathymetric surfaces.

  19. Ecological analysis examining the association between census tract-level incarceration and reported chlamydia incidence among female adolescents and young adults in San Francisco.

    PubMed

    Stoltey, Juliet E; Li, Ye; Bernstein, Kyle T; Philip, Susan S

    2015-08-01

    Incarceration has been linked to increased risk of sexually transmitted infections (STIs). We conducted a census tract-level ecological analysis to explore the relationship between neighbourhood incarceration rates and chlamydia incidence among adolescent girls and young women under age 25 in San Francisco in 2010 to focus public health efforts in neighbourhoods at risk. Female chlamydial cases under age 25 that were reported to the San Francisco Department of Public Health in 2010 were geocoded to census tract, and chlamydia incidence was calculated. Addresses of incarcerated individuals were geocoded, and census tract-specific incarceration was estimated. American Community Survey data from 2005 to 2009 provided tract-specific survey estimates of demographic and socioeconomic characteristics of communities to allow for evaluation of potential census tract-level confounders. A Poisson mixed model was used to assess the relationship of census tract-level incarceration rate with chlamydial case rate. Accounting for spatial dependence in neighbouring regions, there was a positive association between incarceration rates and chlamydia incidence in young women under age 25 in San Francisco, and this association decreased as poverty increased, after controlling for other risk factors in the model. This ecological analysis supports the neighbourhood role of incarceration in the risk of chlamydia among young women. These results have important implications for directing limited public health resources to local areas at risk in order to geographically focus prevention interventions and provide improved access to STI services in specific neighbourhoods with high incarceration rates. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Self-calibration method without joint iteration for distributed small satellite SAR systems

    NASA Astrophysics Data System (ADS)

    Xu, Qing; Liao, Guisheng; Liu, Aifei; Zhang, Juan

    2013-12-01

    The performance of distributed small satellite synthetic aperture radar systems degrades significantly due to the unavoidable array errors, including gain, phase, and position errors, in real operating scenarios. In the conventional method proposed in (IEEE T Aero. Elec. Sys. 42:436-451, 2006), the spectrum components within one Doppler bin are considered as calibration sources. However, it is found in this article that the gain error estimation and the position error estimation in the conventional method can interact with each other. The conventional method may converge to suboptimal solutions in large position errors since it requires the joint iteration between gain-phase error estimation and position error estimation. In addition, it is also found that phase errors can be estimated well regardless of position errors when the zero Doppler bin is chosen. In this article, we propose a method obtained by modifying the conventional one, based on these two observations. In this modified method, gain errors are firstly estimated and compensated, which eliminates the interaction between gain error estimation and position error estimation. Then, by using the zero Doppler bin data, the phase error estimation can be performed well independent of position errors. Finally, position errors are estimated based on the Taylor-series expansion. Meanwhile, the joint iteration between gain-phase error estimation and position error estimation is not required. Therefore, the problem of suboptimal convergence, which occurs in the conventional method, can be avoided with low computational method. The modified method has merits of faster convergence and lower estimation error compared to the conventional one. Theoretical analysis and computer simulation results verified the effectiveness of the modified method.

  1. Visual analysis of geocoded twin data puts nature and nurture on the map.

    PubMed

    Davis, O S P; Haworth, C M A; Lewis, C M; Plomin, R

    2012-09-01

    Twin studies allow us to estimate the relative contributions of nature and nurture to human phenotypes by comparing the resemblance of identical and fraternal twins. Variation in complex traits is a balance of genetic and environmental influences; these influences are typically estimated at a population level. However, what if the balance of nature and nurture varies depending on where we grow up? Here we use statistical and visual analysis of geocoded data from over 6700 families to show that genetic and environmental contributions to 45 childhood cognitive and behavioral phenotypes vary geographically in the United Kingdom. This has implications for detecting environmental exposures that may interact with the genetic influences on complex traits, and for the statistical power of samples recruited for genetic association studies. More broadly, our experience demonstrates the potential for collaborative exploratory visualization to act as a lingua franca for large-scale interdisciplinary research.

  2. A spatial analysis of amyotrophic lateral sclerosis (ALS) cases in the United States and their proximity to multidisciplinary ALS clinics, 2013.

    PubMed

    Horton, D Kevin; Graham, Shannon; Punjani, Reshma; Wilt, Grete; Kaye, Wendy; Maginnis, Kimberly; Webb, Lauren; Richman, Judy; Bedlack, Richard; Tessaro, Edward; Mehta, Paul

    2018-02-01

    Amyotrophic lateral sclerosis (ALS) is a fatal motor neuron disease that typically results in death within 2-5 years of initial symptom onset. Multidisciplinary ALS clinics (MDCs) have been established to provide specialty care to people living with the disease. To estimate the proximity of ALS prevalence cases to the nearest MDC in the US to help evaluate one aspect of access to care. Using 2013 prevalence data from the National ALS Registry, cases were geocoded by city using geographic information system (GIS) software, along with the locations of all MDCs in operation during 2013. Case-to-MDC proximity was calculated and analyzed by sex, race, and age group. During 2013, there were 72 MDCs in operation in 30 different states. A total of 15,633 ALS cases were geocoded and were distributed throughout all 50 states. Of these, 62.6% were male, 77.9% were white, and 76.2% were 50-79 years old. For overall case-to-MDC proximity, nearly half (44.9%) of all geocoded cases in the US lived >50 miles from an MDC, including approximately a quarter who lived >100 miles from an MDC. There was a statistically significant difference between distance to MDC by race and age group. The high percentage of those living more than 50 miles from the nearest specialized clinic underscores one of the many challenges of ALS. Having better access to care, whether at MDCs or through other modalities, is likely key to increasing survivability and obtaining appropriate end-of-life treatment and support for people with ALS.

  3. Analysis of the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery☆

    PubMed Central

    Arba-Mosquera, Samuel; Aslanides, Ioannis M.

    2012-01-01

    Purpose To analyze the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery. Methods A comprehensive model, which directly considers eye movements, including saccades, vestibular, optokinetic, vergence, and miniature, as well as, eye-tracker acquisition rate, eye-tracker latency time, scanner positioning time, laser firing rate, and laser trigger delay have been developed. Results Eye-tracker acquisition rates below 100 Hz correspond to pulse positioning errors above 1.5 mm. Eye-tracker latency times to about 15 ms correspond to pulse positioning errors of up to 3.5 mm. Scanner positioning times to about 9 ms correspond to pulse positioning errors of up to 2 mm. Laser firing rates faster than eye-tracker acquisition rates basically duplicate pulse-positioning errors. Laser trigger delays to about 300 μs have minor to no impact on pulse-positioning errors. Conclusions The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.

  4. Experimental investigation of false positive errors in auditory species occurrence surveys

    USGS Publications Warehouse

    Miller, David A.W.; Weir, Linda A.; McClintock, Brett T.; Grant, Evan H. Campbell; Bailey, Larissa L.; Simons, Theodore R.

    2012-01-01

    False positive errors are a significant component of many ecological data sets, which in combination with false negative errors, can lead to severe biases in conclusions about ecological systems. We present results of a field experiment where observers recorded observations for known combinations of electronically broadcast calling anurans under conditions mimicking field surveys to determine species occurrence. Our objectives were to characterize false positive error probabilities for auditory methods based on a large number of observers, to determine if targeted instruction could be used to reduce false positive error rates, and to establish useful predictors of among-observer and among-species differences in error rates. We recruited 31 observers, ranging in abilities from novice to expert, that recorded detections for 12 species during 180 calling trials (66,960 total observations). All observers made multiple false positive errors and on average 8.1% of recorded detections in the experiment were false positive errors. Additional instruction had only minor effects on error rates. After instruction, false positive error probabilities decreased by 16% for treatment individuals compared to controls with broad confidence interval overlap of 0 (95% CI: -46 to 30%). This coincided with an increase in false negative errors due to the treatment (26%; -3 to 61%). Differences among observers in false positive and in false negative error rates were best predicted by scores from an online test and a self-assessment of observer ability completed prior to the field experiment. In contrast, years of experience conducting call surveys was a weak predictor of error rates. False positive errors were also more common for species that were played more frequently, but were not related to the dominant spectral frequency of the call. Our results corroborate other work that demonstrates false positives are a significant component of species occurrence data collected by auditory methods. Instructing observers to only report detections they are completely certain are correct is not sufficient to eliminate errors. As a result, analytical methods that account for false positive errors will be needed, and independent testing of observer ability is a useful predictor for among-observer variation in observation error rates.

  5. Exploring the potential of geocoding the impact of disasters: The experience of global and national databases

    NASA Astrophysics Data System (ADS)

    Guha-Sapir, Debarati; Davis, Rhonda; Gall, Melanie; Wallemacq, Pascaline; Cutter, Susan

    2015-04-01

    As extreme climate events such as precipitation driven flooding, storms and droughts are increasingly devastating, assessing impacts accurately becomes critically important in guiding decisions and investments on disaster risk reduction. Capturing disaster impacts includes not only quantitative information such as the economic and human effects but also the determination of where and when the impacts occurred. Among the most commonly used impact indicators are the number of deaths and the number of people affected or homeless, and the economic damages. Unfortunately, these figures are typically used in their raw form and conclusions are drawn without due consideration to denominators. For example, key parameters such as the population base or the size of the region affected are often not factored in when judging the severity of the event or calculating increases or decreases in an indicator. To increase the meaningfulness and comparability of disaster impacts across time and space, however, it is important to mathematically standardize indicators and utilize common denominators such as number of population exposed, area affected, GDP, and so forth. Geospatial techniques such as geo-referencing and spatial overlays are coming into greater use to facilitate this process. In 2013, EM-DAT, one of the main providers of global disaster impact data, launched an effort to enhance its contents through spatial analyses. The challenge was to develop a sustainable methodology and protocol for a large dataset and to systematically collect and enter geocoded profiles for each event that is registered in EM-DAT. Along with specialists in geography from different institutions EM-DAT launched an effort to geocode each disaster event working backwards in time starting from the most recent. For geo-referencing purposes, EM-DAT requires a standardized dataset of sub-national administrative boundaries. Though a number of such initiatives exist, the Food and Agriculture Organization's (FAO) Global Administrative Unit Layers (GAUL) was selected as the most appropriate since the data are updated annually, disputed areas are labelled as such and not assigned to a national entity, and the FAO uses a community-based approach whereby users of the dataset can provide updated administrative boundaries and related shapefiles. Geocoding the impact areas of disaster events not only allows for more accurate spatial analyses and mapping but it also enhances the interoperability of EM-DAT data with other spatially explicit data (such as population or land use data), or with nationally-developed loss datasets such as SHELDUS. Most importantly, geocoding permits the monitoring of key parameters of disaster impacts such as exposure, vulnerable populations, effectiveness of disaster risk reduction measures, as well as the investigation of linkages and ripple effects between a catastrophic event and other external factors. For example, the intersection between extreme malnutrition and the spatial extent of droughts or floods aids in the identification of hot spots and facilitates strategic delivery of nutrition interventions. With the need for tracking and monitoring progress towards sustainable development and disaster risk reduction gaining in importance, the ability to express disaster impacts in standardized terms such as ratios or percentages per some unit area will increase transparency and comparability of disaster management programmes.

  6. Spatial Analysis of HIV Positive Injection Drug Users in San Francisco, 1987 to 2005

    PubMed Central

    Martinez, Alexis N.; Mobley, Lee R.; Lorvick, Jennifer; Novak, Scott P.; Lopez, Andrea M.; Kral, Alex H.

    2014-01-01

    Spatial analyses of HIV/AIDS related outcomes are growing in popularity as a tool to understand geographic changes in the epidemic and inform the effectiveness of community-based prevention and treatment programs. The Urban Health Study was a serial, cross-sectional epidemiological study of injection drug users (IDUs) in San Francisco between 1987 and 2005 (N = 29,914). HIV testing was conducted for every participant. Participant residence was geocoded to the level of the United States Census tract for every observation in dataset. Local indicator of spatial autocorrelation (LISA) tests were used to identify univariate and bivariate Census tract clusters of HIV positive IDUs in two time periods. We further compared three tract level characteristics (% poverty, % African Americans, and % unemployment) across areas of clustered and non-clustered tracts. We identified significant spatial clustering of high numbers of HIV positive IDUs in the early period (1987–1995) and late period (1996–2005). We found significant bivariate clusters of Census tracts where HIV positive IDUs and tract level poverty were above average compared to the surrounding areas. Our data suggest that poverty, rather than race, was an important neighborhood characteristic associated with the spatial distribution of HIV in SF and its spatial diffusion over time. PMID:24722543

  7. Research on the error model of airborne celestial/inertial integrated navigation system

    NASA Astrophysics Data System (ADS)

    Zheng, Xiaoqiang; Deng, Xiaoguo; Yang, Xiaoxu; Dong, Qiang

    2015-02-01

    Celestial navigation subsystem of airborne celestial/inertial integrated navigation system periodically correct the positioning error and heading drift of the inertial navigation system, by which the inertial navigation system can greatly improve the accuracy of long-endurance navigation. Thus the navigation accuracy of airborne celestial navigation subsystem directly decides the accuracy of the integrated navigation system if it works for long time. By building the mathematical model of the airborne celestial navigation system based on the inertial navigation system, using the method of linear coordinate transformation, we establish the error transfer equation for the positioning algorithm of airborne celestial system. Based on these we built the positioning error model of the celestial navigation. And then, based on the positioning error model we analyze and simulate the positioning error which are caused by the error of the star tracking platform with the MATLAB software. Finally, the positioning error model is verified by the information of the star obtained from the optical measurement device in range and the device whose location are known. The analysis and simulation results show that the level accuracy and north accuracy of tracking platform are important factors that limit airborne celestial navigation systems to improve the positioning accuracy, and the positioning error have an approximate linear relationship with the level error and north error of tracking platform. The error of the verification results are in 1000m, which shows that the model is correct.

  8. SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ju, S; Hong, C; Kim, M

    Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed withoutmore » the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.« less

  9. ARES - A New Airborne Reflective Emissive Spectrometer

    DTIC Science & Technology

    2005-10-01

    Information and Management System (DIMS), an automated processing environment with robot archive interface as established for the handling of satellite data...consisting of geocoded ground reflectance data. All described processing steps will be integrated in the automated processing environment DIMS to assure a

  10. VIOLENT CRIME EXPOSURE CLASSIFICATION AND ADVERSE BIRTH OUTCOMES: A GEOGRAPHICALLY-DEFINED COHORT STUDY

    EPA Science Inventory

    Background

    Area-level socioeconomic disparities have long been associated with adverse pregnancy outcomes. Crime is an important element of the neighborhood environment inadequately investigated in the public health literature. Using geocoded linked birth, crime and cens...

  11. A spatial analysis of amyotrophic lateral sclerosis (ALS) cases in the United States and their proximity to multidisciplinary ALS clinics, 2013

    PubMed Central

    Horton, D. Kevin; Graham, Shannon; Punjani, Reshma; Wilt, Grete; Kaye, Wendy; Maginnis, Kimberly; Webb, Lauren; Richman, Judy; Bedlack, Richard; Tessaro, Edward; Mehta, Paul

    2017-01-01

    Background Amyotrophic lateral sclerosis (ALS) is a fatal motor neuron disease that typically results in death within 2–5 years of initial symptom onset. Multidisciplinary ALS clinics (MDCs) have been established to provide specialty care to people living with the disease. Objective To estimate the proximity of ALS prevalence cases to the nearest MDC in the US to help evaluate one aspect of access to care. Methods Using 2013 prevalence data from the National ALS Registry, cases were geocoded by city using geographic information system (GIS) software, along with the locations of all MDCs in operation during 2013. Case-to-MDC proximity was calculated and analyzed by sex, race, and age group. Results During 2013, there were 72 MDCs in operation in 30 different states. A total of 15,633 ALS cases were geocoded and were distributed throughout all 50 states. Of these, 62.6% were male, 77.9% were white, and 76.2% were 50–79 years old. For overall case-to-MDC proximity, nearly half (44.9%) of all geocoded cases in the US lived >50 miles from an MDC, including approximately a quarter who lived >100 miles from an MDC. There was a statistically significant difference between distance to MDC by race and age group. Conclusions The high percentage of those living more than 50 miles from the nearest specialized clinic underscores one of the many challenges of ALS. Having better access to care, whether at MDCs or through other modalities, is likely key to increasing survivability and obtaining appropriate end-of-life treatment and support for people with ALS. PMID:29262737

  12. National Geocoding Converter File 1 : Volume 3. Montana to Wyoming.

    DOT National Transportation Integrated Search

    1974-01-01

    This file contains a record for each county, county equivalent (as defined by the Census Bureau), SMSA county segment and SPLC county segment in the U.S. A record identifies for an area all major county codes and the associated county aggregate codes

  13. National Geocoding Converter File 1 : Volume 1. Structure & Content.

    DOT National Transportation Integrated Search

    1974-01-01

    This file contains a record for each county, county equivalent (as defined by the Census Bureau), SMSA county segment and SPLC county segment in the U.S. A record identifies for an area all major county codes and the associated county aggregate codes

  14. Safe main street highways part I : Washington state collision data and geocoding.

    DOT National Transportation Integrated Search

    2017-09-01

    This project contributes to the Washington State Strategic Highway Safety Plan, whose goals are to achieve zero road fatality and serious injury by 2030 and to reduce the number of pedestrians and bicyclists involved in motor-vehicle collisions on st...

  15. Spatiotemporal historical datasets at micro-level for geocoded individuals in five Swedish parishes, 1813–1914

    PubMed Central

    Hedefalk, Finn; Svensson, Patrick; Harrie, Lars

    2017-01-01

    This paper presents datasets that enable historical longitudinal studies of micro-level geographic factors in a rural setting. These types of datasets are new, as historical demography studies have generally failed to properly include the micro-level geographic factors. Our datasets describe the geography over five Swedish rural parishes, and by linking them to a longitudinal demographic database, we obtain a geocoded population (at the property unit level) for this area for the period 1813–1914. The population is a subset of the Scanian Economic Demographic Database (SEDD). The geographic information includes the following feature types: property units, wetlands, buildings, roads and railroads. The property units and wetlands are stored in object-lifeline time representations (information about creation, changes and ends of objects are recorded in time), whereas the other feature types are stored as snapshots in time. Thus, the datasets present one of the first opportunities to study historical spatio-temporal patterns at the micro-level. PMID:28398288

  16. Action errors, error management, and learning in organizations.

    PubMed

    Frese, Michael; Keith, Nina

    2015-01-03

    Every organization is confronted with errors. Most errors are corrected easily, but some may lead to negative consequences. Organizations often focus on error prevention as a single strategy for dealing with errors. Our review suggests that error prevention needs to be supplemented by error management--an approach directed at effectively dealing with errors after they have occurred, with the goal of minimizing negative and maximizing positive error consequences (examples of the latter are learning and innovations). After defining errors and related concepts, we review research on error-related processes affected by error management (error detection, damage control). Empirical evidence on positive effects of error management in individuals and organizations is then discussed, along with emotional, motivational, cognitive, and behavioral pathways of these effects. Learning from errors is central, but like other positive consequences, learning occurs under certain circumstances--one being the development of a mind-set of acceptance of human error.

  17. Hyperspectral Technique for Detecting Soil Parameters

    NASA Astrophysics Data System (ADS)

    Garfagnoli, F.; Ciampalini, A.; Moretti, S.; Chiarantini, L.

    2011-12-01

    In satellite and airborne remote sensing, hyperspectral technique has become a very powerful tool, due to the possibility of rapidly realizing chemical/mineralogical maps of the studied areas. Many studies are trying to customize the algorithms to identify several geo-physical soil properties. The specific objective of this study is to investigate those soil characteristics, such as clay mineral content, influencing degradation processes (soil erosion and shallow landslides), by means of correlation analysis, in order to examine the possibility of predicting the selected property using high-resolution reflectance spectra and images. The study area is located in the Mugello basin, about 30 km north of Firenze (Tuscany, Italy). Agriculturally suitable terrains are assigned mainly to annual crops, marginally to olive groves, vineyards and orchards. Soils mostly belong to Regosols and Cambisols orders. An ASD FieldSpec spectroradiometer was used to obtain reflectance spectra from about 80 dried, crushed and sieved samples under controlled laboratory conditions. Samples were collected simultaneously with the flight of SIM.GA hyperspectral camera from Selex Galileo, over an area of about 5 km2 and their positions were recorded with a differential GPS. The quantitative determination of clay minerals content was performed by means of XRD and Rietveld refinement. Different chemometric techniques were preliminarily tested to correlate mineralogical records with reflectance data. A one component partial least squares regression model yielded a preliminary R2 value of 0.65. A slightly better result was achieved by plotting the absorption peak depth at 2210 versus total clay content (band-depth analysis). The complete SIM.GA hyperspectral geocoded row dataset, with an approximate pixel resolution of 0.6 m (VNIR) and 1.2 m (SWIR), was firstly transformed into at sensor radiance values, by applying calibration coefficients and parameters from laboratory measurements to non-georeferred VNIR/SWIR DN values. Then, airborne imagery needed to be corrected for the influence of the atmosphere, solar illumination, sensor viewing geometry and terrain geometry information, for the retrieval of inherent surface reflectance properties. The geocoded products were obtained for each flight line by using a procedure developed in IDL Language and PARGE (PARametric Geocoding) software. When all compensation parameters were applied to hyperspectral data or to the final thematic map, orthorectified, georeferred and coregistered VNIR to SWIR images or maps were available for GIS application and 3D view as well as for the retrieval of different geophysical parameters by means of inversion algorithms. The experimental fitting of laboratory data on mineral content is used for airborne data inversion, whose results are in agreement with laboratory records, demonstrating the possibility to use this methodology for digital mapping of soil properties. In this study, we established a complete procedure for mapping clay content areal variations in agricultural soils starting form airborne hyperspectral imagery.

  18. Interferometric correction system for a numerically controlled machine

    DOEpatents

    Burleson, Robert R.

    1978-01-01

    An interferometric correction system for a numerically controlled machine is provided to improve the positioning accuracy of a machine tool, for example, for a high-precision numerically controlled machine. A laser interferometer feedback system is used to monitor the positioning of the machine tool which is being moved by command pulses to a positioning system to position the tool. The correction system compares the commanded position as indicated by a command pulse train applied to the positioning system with the actual position of the tool as monitored by the laser interferometer. If the tool position lags the commanded position by a preselected error, additional pulses are added to the pulse train applied to the positioning system to advance the tool closer to the commanded position, thereby reducing the lag error. If the actual tool position is leading in comparison to the commanded position, pulses are deleted from the pulse train where the advance error exceeds the preselected error magnitude to correct the position error of the tool relative to the commanded position.

  19. Segregation and preterm birth: The effects of neighborhood racial composition in North Carolina

    EPA Science Inventory

    Epidemiologic research suggests that racial segregation is associated with poor health among blacks in the United States (US). We used geocoded birth records and US census data to investigate whether neighborhood-level percent black is associated with preterm birth (PTB) for blac...

  20. Adaptive error detection for HDR/PDR brachytherapy: Guidance for decision making during real-time in vivo point dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertzscher, Gustavo, E-mail: guke@dtu.dk; Andersen, Claus E., E-mail: clan@dtu.dk; Tanderup, Kari, E-mail: karitand@rm.dk

    Purpose: This study presents an adaptive error detection algorithm (AEDA) for real-timein vivo point dosimetry during high dose rate (HDR) or pulsed dose rate (PDR) brachytherapy (BT) where the error identification, in contrast to existing approaches, does not depend on an a priori reconstruction of the dosimeter position. Instead, the treatment is judged based on dose rate comparisons between measurements and calculations of the most viable dosimeter position provided by the AEDA in a data driven approach. As a result, the AEDA compensates for false error cases related to systematic effects of the dosimeter position reconstruction. Given its nearly exclusivemore » dependence on stable dosimeter positioning, the AEDA allows for a substantially simplified and time efficient real-time in vivo BT dosimetry implementation. Methods: In the event of a measured potential treatment error, the AEDA proposes the most viable dosimeter position out of alternatives to the original reconstruction by means of a data driven matching procedure between dose rate distributions. If measured dose rates do not differ significantly from the most viable alternative, the initial error indication may be attributed to a mispositioned or misreconstructed dosimeter (false error). However, if the error declaration persists, no viable dosimeter position can be found to explain the error, hence the discrepancy is more likely to originate from a misplaced or misreconstructed source applicator or from erroneously connected source guide tubes (true error). Results: The AEDA applied on twoin vivo dosimetry implementations for pulsed dose rate BT demonstrated that the AEDA correctly described effects responsible for initial error indications. The AEDA was able to correctly identify the major part of all permutations of simulated guide tube swap errors and simulated shifts of individual needles from the original reconstruction. Unidentified errors corresponded to scenarios where the dosimeter position was sufficiently symmetric with respect to error and no-error source position constellations. The AEDA was able to correctly identify all false errors represented by mispositioned dosimeters contrary to an error detection algorithm relying on the original reconstruction. Conclusions: The study demonstrates that the AEDA error identification during HDR/PDR BT relies on a stable dosimeter position rather than on an accurate dosimeter reconstruction, and the AEDA’s capacity to distinguish between true and false error scenarios. The study further shows that the AEDA can offer guidance in decision making in the event of potential errors detected with real-timein vivo point dosimetry.« less

  1. Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bai, Sen; Li, Guangjun; Wang, Maojie

    The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors weremore » 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.« less

  2. Precise Geolocation Of Persistent Scatterers Aided And Validated By Lidar DSM

    NASA Astrophysics Data System (ADS)

    Chang, Ling; Dheenathayalan, Prabu; Hanessen, Ramon

    2013-12-01

    Persistent Scatterers (PS) interferometry results in the de- formation history of time-coherent scatterers. Although several applications focus on smooth, spatially correlated signals, we aim for the detection, identification and analysis of single anomalies. These targets can be indicative of, e.g., strain in structures, potentially leading to the failure of such structures. For the identification and analysis it is of the greatest importance to know the exact position of the effective scattering center, to avoid an improper interpretation of the driving mechanism. Here we present an approach to optimize the geolocation of important scatterers, when necessary aided by an a priori Lidar-derived DSM (AHN-1 data) with 15cm and 5m resolution in vertical and horizontal directions, respectively. The DSM is also used to validate the geocoding. We implement our approach on a near-collapse event of a shopping mall in Heerlen, the Netherlands, to generate the precise geolocation of local PS points.

  3. Aliasing errors in measurements of beam position and ellipticity

    NASA Astrophysics Data System (ADS)

    Ekdahl, Carl

    2005-09-01

    Beam position monitors (BPMs) are used in accelerators and ion experiments to measure currents, position, and azimuthal asymmetry. These usually consist of discrete arrays of electromagnetic field detectors, with detectors located at several equally spaced azimuthal positions at the beam tube wall. The discrete nature of these arrays introduces systematic errors into the data, independent of uncertainties resulting from signal noise, lack of recording dynamic range, etc. Computer simulations were used to understand and quantify these aliasing errors. If required, aliasing errors can be significantly reduced by employing more than the usual four detectors in the BPMs. These simulations show that the error in measurements of the centroid position of a large beam is indistinguishable from the error in the position of a filament. The simulations also show that aliasing errors in the measurement of beam ellipticity are very large unless the beam is accurately centered. The simulations were used to quantify the aliasing errors in beam parameter measurements during early experiments on the DARHT-II accelerator, demonstrating that they affected the measurements only slightly, if at all.

  4. Panel positioning error and support mechanism for a 30-m THz radio telescope

    NASA Astrophysics Data System (ADS)

    Yang, De-Hua; Okoh, Daniel; Zhou, Guo-Hua; Li, Ai-Hua; Li, Guo-Ping; Cheng, Jing-Quan

    2011-06-01

    A 30-m TeraHertz (THz) radio telescope is proposed to operate at 200 μm with an active primary surface. This paper presents sensitivity analysis of active surface panel positioning errors with optical performance in terms of the Strehl ratio. Based on Ruze's surface error theory and using a Monte Carlo simulation, the effects of six rigid panel positioning errors, such as piston, tip, tilt, radial, azimuthal and twist displacements, were directly derived. The optical performance of the telescope was then evaluated using the standard Strehl ratio. We graphically illustrated the various panel error effects by presenting simulations of complete ensembles of full reflector surface errors for the six different rigid panel positioning errors. Study of the panel error sensitivity analysis revealed that the piston error and tilt/tip errors are dominant while the other rigid errors are much less important. Furthermore, as indicated by the results, we conceived of an alternative Master-Slave Concept-based (MSC-based) active surface by implementating a special Series-Parallel Concept-based (SPC-based) hexapod as the active panel support mechanism. A new 30-m active reflector based on the two concepts was demonstrated to achieve correction for all the six rigid panel positioning errors in an economically feasible way.

  5. A methodology for translating positional error into measures of attribute error, and combining the two error sources

    Treesearch

    Yohay Carmel; Curtis Flather; Denis Dean

    2006-01-01

    This paper summarizes our efforts to investigate the nature, behavior, and implications of positional error and attribute error in spatiotemporal datasets. Estimating the combined influence of these errors on map analysis has been hindered by the fact that these two error types are traditionally expressed in different units (distance units, and categorical units,...

  6. The Rise of School-Supporting Nonprofits

    ERIC Educational Resources Information Center

    Nelson, Ashlyn Aiko; Gazley, Beth

    2014-01-01

    This paper examines voluntary contributions to public education via charitable school foundations, booster clubs, parent teacher associations, and parent teacher organizations. We use panel data on school-supporting charities with national coverage from 1995 to 2010, which we geocode and match to school districts. We document the meteoric rise of…

  7. 75 FR 80677 - The Low-Income Definition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-23

    ... original regulatory text so it is consistent with the geo-coding software the agency uses to make the low... Union Act (Act) authorizes the NCUA Board (Board) to define ``low-income members'' so that credit unions... process of implementing geo- coding software to make the calculation automatically for credit unions...

  8. Neighborhood Disadvantage and Variations in Blood Pressure

    ERIC Educational Resources Information Center

    Cathorall, Michelle L.; Xin, Huaibo; Peachey, Andrew; Bibeau, Daniel L.; Schulz, Mark; Aronson, Robert

    2015-01-01

    Purpose: To examine the extent to which neighborhood disadvantage accounts for variation in blood pressure. Methods: Demographic, biometric, and self-reported data from 19,261 health screenings were used. Addresses of participants were geocoded and located within census block groups (n = 14,510, 75.3%). Three hierarchical linear models were…

  9. Characterisation of false-positive observations in botanical surveys

    PubMed Central

    2017-01-01

    Errors in botanical surveying are a common problem. The presence of a species is easily overlooked, leading to false-absences; while misidentifications and other mistakes lead to false-positive observations. While it is common knowledge that these errors occur, there are few data that can be used to quantify and describe these errors. Here we characterise false-positive errors for a controlled set of surveys conducted as part of a field identification test of botanical skill. Surveys were conducted at sites with a verified list of vascular plant species. The candidates were asked to list all the species they could identify in a defined botanically rich area. They were told beforehand that their final score would be the sum of the correct species they listed, but false-positive errors counted against their overall grade. The number of errors varied considerably between people, some people create a high proportion of false-positive errors, but these are scattered across all skill levels. Therefore, a person’s ability to correctly identify a large number of species is not a safeguard against the generation of false-positive errors. There was no phylogenetic pattern to falsely observed species; however, rare species are more likely to be false-positive as are species from species rich genera. Raising the threshold for the acceptance of an observation reduced false-positive observations dramatically, but at the expense of more false negative errors. False-positive errors are higher in field surveying of plants than many people may appreciate. Greater stringency is required before accepting species as present at a site, particularly for rare species. Combining multiple surveys resolves the problem, but requires a considerable increase in effort to achieve the same sensitivity as a single survey. Therefore, other methods should be used to raise the threshold for the acceptance of a species. For example, digital data input systems that can verify, feedback and inform the user are likely to reduce false-positive errors significantly. PMID:28533972

  10. Experimental investigation of observation error in anuran call surveys

    USGS Publications Warehouse

    McClintock, B.T.; Bailey, L.L.; Pollock, K.H.; Simons, T.R.

    2010-01-01

    Occupancy models that account for imperfect detection are often used to monitor anuran and songbird species occurrence. However, presenceabsence data arising from auditory detections may be more prone to observation error (e.g., false-positive detections) than are sampling approaches utilizing physical captures or sightings of individuals. We conducted realistic, replicated field experiments using a remote broadcasting system to simulate simple anuran call surveys and to investigate potential factors affecting observation error in these studies. Distance, time, ambient noise, and observer abilities were the most important factors explaining false-negative detections. Distance and observer ability were the best overall predictors of false-positive errors, but ambient noise and competing species also affected error rates for some species. False-positive errors made up 5 of all positive detections, with individual observers exhibiting false-positive rates between 0.5 and 14. Previous research suggests false-positive errors of these magnitudes would induce substantial positive biases in standard estimators of species occurrence, and we recommend practices to mitigate for false positives when developing occupancy monitoring protocols that rely on auditory detections. These recommendations include additional observer training, limiting the number of target species, and establishing distance and ambient noise thresholds during surveys. ?? 2010 The Wildlife Society.

  11. A dengue outbreak on a floating village at Cat Ba Island in Vietnam.

    PubMed

    Le Viet, Thanh; Choisy, Marc; Bryant, Juliet E; Vu Trong, Duoc; Pham Quang, Thai; Horby, Peter; Nguyen Tran, Hien; Tran Thi Kieu, Huong; Nguyen Vu, Trung; Nguyen Van, Kinh; Le Quynh, Mai; Wertheim, Heiman F L

    2015-09-22

    A dengue outbreak in an ecotourism destination spot in Vietnam, from September to November 2013, impacted a floating village of fishermen on the coastal island of Cat Ba. The outbreak raises questions about how tourism may impact disease spread in rural areas. Epidemiological data were obtained from the Hai Phong Preventive Medical Center (PMC), including case histories and residential location from all notified dengue cases from this outbreak. All household addresses were geo-located. Knox test, a spatio-temporal analysis that enables inference dengue clustering constrained by space and time, was performed on the geocoded locations. From the plasma available from two patients, positive for Dengue serotype 3 virus (DENV3), the Envelope (E) gene was sequenced, and their genetic relationships compared to other E sequences in the region. Of 192 dengue cases, the odds ratio of contracting dengue infections for people living in the floating villages compared to those living on the island was 4.9 (95 % CI: 3.6-6.7). The space-time analyses on 111 geocoded dengue residences found the risk of dengue infection to be the highest within 4 days and a radius of 20 m of a given case. Of the total of ten detected clusters with an excess risk greater than 2, the cluster with the highest number of cases was in the floating village area (24 patients for a total duration of 31 days). Phylogenetic analysis revealed a high homology of the two DENV3 strains (genotype III) from Cat Ba with DENV3 viruses circulating in Hanoi in the same year (99.1 %). Our study showed that dengue transmission is unlikely to be sustained on Cat Ba Island and that the 2013 epidemic likely originated through introduction of viruses from the mainland, potentially Hanoi. These findings suggest that prevention efforts should be focused on mainland rather than on the island.

  12. Position Error Covariance Matrix Validation and Correction

    NASA Technical Reports Server (NTRS)

    Frisbee, Joe, Jr.

    2016-01-01

    In order to calculate operationally accurate collision probabilities, the position error covariance matrices predicted at times of closest approach must be sufficiently accurate representations of the position uncertainties. This presentation will discuss why the Gaussian distribution is a reasonable expectation for the position uncertainty and how this assumed distribution type is used in the validation and correction of position error covariance matrices.

  13. ADEPT, a dynamic next generation sequencing data error-detection program with trimming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Shihai; Lo, Chien-Chi; Li, Po-E

    Illumina is the most widely used next generation sequencing technology and produces millions of short reads that contain errors. These sequencing errors constitute a major problem in applications such as de novo genome assembly, metagenomics analysis and single nucleotide polymorphism discovery. In this study, we present ADEPT, a dynamic error detection method, based on the quality scores of each nucleotide and its neighboring nucleotides, together with their positions within the read and compares this to the position-specific quality score distribution of all bases within the sequencing run. This method greatly improves upon other available methods in terms of the truemore » positive rate of error discovery without affecting the false positive rate, particularly within the middle of reads. We conclude that ADEPT is the only tool to date that dynamically assesses errors within reads by comparing position-specific and neighboring base quality scores with the distribution of quality scores for the dataset being analyzed. The result is a method that is less prone to position-dependent under-prediction, which is one of the most prominent issues in error prediction. The outcome is that ADEPT improves upon prior efforts in identifying true errors, primarily within the middle of reads, while reducing the false positive rate.« less

  14. ADEPT, a dynamic next generation sequencing data error-detection program with trimming

    DOE PAGES

    Feng, Shihai; Lo, Chien-Chi; Li, Po-E; ...

    2016-02-29

    Illumina is the most widely used next generation sequencing technology and produces millions of short reads that contain errors. These sequencing errors constitute a major problem in applications such as de novo genome assembly, metagenomics analysis and single nucleotide polymorphism discovery. In this study, we present ADEPT, a dynamic error detection method, based on the quality scores of each nucleotide and its neighboring nucleotides, together with their positions within the read and compares this to the position-specific quality score distribution of all bases within the sequencing run. This method greatly improves upon other available methods in terms of the truemore » positive rate of error discovery without affecting the false positive rate, particularly within the middle of reads. We conclude that ADEPT is the only tool to date that dynamically assesses errors within reads by comparing position-specific and neighboring base quality scores with the distribution of quality scores for the dataset being analyzed. The result is a method that is less prone to position-dependent under-prediction, which is one of the most prominent issues in error prediction. The outcome is that ADEPT improves upon prior efforts in identifying true errors, primarily within the middle of reads, while reducing the false positive rate.« less

  15. Flight calibration of compensated and uncompensated pitot-static airspeed probes and application of the probes to supersonic cruise vehicles

    NASA Technical Reports Server (NTRS)

    Webb, L. D.; Washington, H. P.

    1972-01-01

    Static pressure position error calibrations for a compensated and an uncompensated XB-70 nose boom pitot static probe were obtained in flight. The methods (Pacer, acceleration-deceleration, and total temperature) used to obtain the position errors over a Mach number range from 0.5 to 3.0 and an altitude range from 25,000 feet to 70,000 feet are discussed. The error calibrations are compared with the position error determined from wind tunnel tests, theoretical analysis, and a standard NACA pitot static probe. Factors which influence position errors, such as angle of attack, Reynolds number, probe tip geometry, static orifice location, and probe shape, are discussed. Also included are examples showing how the uncertainties caused by position errors can affect the inlet controls and vertical altitude separation of a supersonic transport.

  16. Precise Positioning Method for Logistics Tracking Systems Using Personal Handy-Phone System Based on Mahalanobis Distance

    NASA Astrophysics Data System (ADS)

    Yokoi, Naoaki; Kawahara, Yasuhiro; Hosaka, Hiroshi; Sakata, Kenji

    Focusing on the Personal Handy-phone System (PHS) positioning service used in physical distribution logistics, a positioning error offset method for improving positioning accuracy is invented. A disadvantage of PHS positioning is that measurement errors caused by the fluctuation of radio waves due to buildings around the terminal are large, ranging from several tens to several hundreds of meters. In this study, an error offset method is developed, which learns patterns of positioning results (latitude and longitude) containing errors and the highest signal strength at major logistic points in advance, and matches them with new data measured in actual distribution processes according to the Mahalanobis distance. Then the matching resolution is improved to 1/40 that of the conventional error offset method.

  17. A simulation of GPS and differential GPS sensors

    NASA Technical Reports Server (NTRS)

    Rankin, James M.

    1993-01-01

    The Global Positioning System (GPS) is a revolutionary advance in navigation. Users can determine latitude, longitude, and altitude by receiving range information from at least four satellites. The statistical accuracy of the user's position is directly proportional to the statistical accuracy of the range measurement. Range errors are caused by clock errors, ephemeris errors, atmospheric delays, multipath errors, and receiver noise. Selective Availability, which the military uses to intentionally degrade accuracy for non-authorized users, is a major error source. The proportionality constant relating position errors to range errors is the Dilution of Precision (DOP) which is a function of the satellite geometry. Receivers separated by relatively short distances have the same satellite and atmospheric errors. Differential GPS (DGPS) removes these errors by transmitting pseudorange corrections from a fixed receiver to a mobile receiver. The corrected pseudorange at the moving receiver is now corrupted only by errors from the receiver clock, multipath, and measurement noise. This paper describes a software package that models position errors for various GPS and DGPS systems. The error model is used in the Real-Time Simulator and Cockpit Technology workstation simulations at NASA-LaRC. The GPS/DGPS sensor can simulate enroute navigation, instrument approaches, or on-airport navigation.

  18. An error analysis perspective for patient alignment systems.

    PubMed

    Figl, Michael; Kaar, Marcus; Hoffman, Rainer; Kratochwil, Alfred; Hummel, Johann

    2013-09-01

    This paper analyses the effects of error sources which can be found in patient alignment systems. As an example, an ultrasound (US) repositioning system and its transformation chain are assessed. The findings of this concept can also be applied to any navigation system. In a first step, all error sources were identified and where applicable, corresponding target registration errors were computed. By applying error propagation calculations on these commonly used registration/calibration and tracking errors, we were able to analyse the components of the overall error. Furthermore, we defined a special situation where the whole registration chain reduces to the error caused by the tracking system. Additionally, we used a phantom to evaluate the errors arising from the image-to-image registration procedure, depending on the image metric used. We have also discussed how this analysis can be applied to other positioning systems such as Cone Beam CT-based systems or Brainlab's ExacTrac. The estimates found by our error propagation analysis are in good agreement with the numbers found in the phantom study but significantly smaller than results from patient evaluations. We probably underestimated human influences such as the US scan head positioning by the operator and tissue deformation. Rotational errors of the tracking system can multiply these errors, depending on the relative position of tracker and probe. We were able to analyse the components of the overall error of a typical patient positioning system. We consider this to be a contribution to the optimization of the positioning accuracy for computer guidance systems.

  19. NASADEM Initial Production Processing Results: Shuttle Radar Topography Mission (SRTM) Reprocessing with Improvements

    NASA Astrophysics Data System (ADS)

    Buckley, S.; Agram, P. S.; Belz, J. E.; Crippen, R. E.; Gurrola, E. M.; Hensley, S.; Kobrick, M.; Lavalle, M.; Martin, J. M.; Neumann, M.; Nguyen, Q.; Rosen, P. A.; Shimada, J.; Simard, M.; Tung, W.

    2016-12-01

    NASADEM is a significant modernization of SRTM digital elevation model (DEM) data supported by the NASA MEaSUREs program. We are reprocessing the raw radar signal data using improved algorithms and incorporating ICESat and DEM data unavailable during the original processing. The NASADEM products will be freely-available through the Land Processes Distributed Active Archive Center (LPDAAC) at one-arcsecond spacing and delivered by continent: North America, South America, Australia, Eurasia, Africa, and Island Groups. We are in the production phase of the project. This involves radar interferometry (InSAR) processing on thousands of radar datatakes. New phase unwrapping and height ripple error correction (HREC) procedures are applied to the data. The resulting strip DEMs and ancillary information are passed to a back-end processor to create DEM mosaics and new geocoded single-swath products. Manual data quality assessment (QA) and fixes are performed at several steps in the processing chain. Post-production DEM void-filling is described in a companion AGU Fall Meeting presentation. The team completed the InSAR processing for all continents and the manual QA of the strip DEMs for more than half the world. North America strip DEM void areas are reduced by more than 50%. The ICESat data is used for height ripple error correction and as control for continent-scale adjustment of the strip DEMs. These ripples are due to uncompensated mast motion most pronounced after Shuttle roll angle adjustment maneuvers. After an initial assessment of the NASADEM production processing for the Americas, we further refined the selection of ICESat data for control by excluded data over glaciers, snow cover, forest clear cuts, and sloped areas. The HREC algorithm reduces the North America ICESat-SRTM bias from 80 cm to 3 cm and the RMS from 5m to 4m.

  20. Realtime mitigation of GPS SA errors using Loran-C

    NASA Technical Reports Server (NTRS)

    Braasch, Soo Y.

    1994-01-01

    The hybrid use of Loran-C with the Global Positioning System (GPS) was shown capable of providing a sole-means of enroute air radionavigation. By allowing pilots to fly direct to their destinations, use of this system is resulting in significant time savings and therefore fuel savings as well. However, a major error source limiting the accuracy of GPS is the intentional degradation of the GPS signal known as Selective Availability (SA). SA-induced position errors are highly correlated and far exceed all other error sources (horizontal position error: 100 meters, 95 percent). Realtime mitigation of SA errors from the position solution is highly desirable. How that can be achieved is discussed. The stability of Loran-C signals is exploited to reduce SA errors. The theory behind this technique is discussed and results using bench and flight data are given.

  1. Definition of an Enhanced Map-Matching Algorithm for Urban Environments with Poor GNSS Signal Quality.

    PubMed

    Jiménez, Felipe; Monzón, Sergio; Naranjo, Jose Eugenio

    2016-02-04

    Vehicle positioning is a key factor for numerous information and assistance applications that are included in vehicles and for which satellite positioning is mainly used. However, this positioning process can result in errors and lead to measurement uncertainties. These errors come mainly from two sources: errors and simplifications of digital maps and errors in locating the vehicle. From that inaccurate data, the task of assigning the vehicle's location to a link on the digital map at every instant is carried out by map-matching algorithms. These algorithms have been developed to fulfil that need and attempt to amend these errors to offer the user a suitable positioning. In this research; an algorithm is developed that attempts to solve the errors in positioning when the Global Navigation Satellite System (GNSS) signal reception is frequently lost. The algorithm has been tested with satisfactory results in a complex urban environment of narrow streets and tall buildings where errors and signal reception losses of the GPS receiver are frequent.

  2. Definition of an Enhanced Map-Matching Algorithm for Urban Environments with Poor GNSS Signal Quality

    PubMed Central

    Jiménez, Felipe; Monzón, Sergio; Naranjo, Jose Eugenio

    2016-01-01

    Vehicle positioning is a key factor for numerous information and assistance applications that are included in vehicles and for which satellite positioning is mainly used. However, this positioning process can result in errors and lead to measurement uncertainties. These errors come mainly from two sources: errors and simplifications of digital maps and errors in locating the vehicle. From that inaccurate data, the task of assigning the vehicle’s location to a link on the digital map at every instant is carried out by map-matching algorithms. These algorithms have been developed to fulfil that need and attempt to amend these errors to offer the user a suitable positioning. In this research; an algorithm is developed that attempts to solve the errors in positioning when the Global Navigation Satellite System (GNSS) signal reception is frequently lost. The algorithm has been tested with satisfactory results in a complex urban environment of narrow streets and tall buildings where errors and signal reception losses of the GPS receiver are frequent. PMID:26861320

  3. The Social Meaning of Sharing and Geocoding: Features and Social Processes in Online Communities

    ERIC Educational Resources Information Center

    Xiong, Li

    2012-01-01

    This study examines how emergent communities might show different patterns of uses and perceptions for communication and profile features when geolocation features are used. It explores the ways that location awareness moderates the social and cognitive processes that motivate people's participation in the sharing of personal information…

  4. Equity Indicators: Measures of Socio-Economic Status at Victoria University.

    ERIC Educational Resources Information Center

    Sinclair, Genevieve; Doughney, James; Palermo, Josephine

    After a review of relevant literature on socioeconomic status (SES) and the ways in which is used for higher education institutional research and policy, a detailed data analysis of Victoria University (VU), Australia student data was undertaken. Between 10,000 and 15,000 domestic student addresses were geocoded to Australian Bureau of Statistics…

  5. 78 FR 64212 - Information Collections Being Reviewed by the Federal Communications Commission; Comments Requested

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-28

    ... Investment Annual Milestone Reports; Changes in Phase I Deployments; and Connect America Phase II State-Level... information to the Commission. However, respondents may request materials or information submitted to the... approval is sought are the Geocoded Information for Phase I Two- and Three-Year Milestone Reports...

  6. Do Head Start Impacts Vary by Neighborhood Context?

    ERIC Educational Resources Information Center

    Morris, Pamela A.; Connors, Maia C.; McCoy, Dana Charles; Gomez, Celia J.; Yoshikawa, Hiro; Aber, J. Lawrence

    2014-01-01

    This paper capitalizes on the addition of geocodes for Head Start centers in which children were randomly assigned to address questions about the role of neighborhood characteristics in moderating impacts of assignment to the Head Start program. Researchers explore the extent to which impacts of assignment to Head Start on outcomes for children…

  7. 76 FR 12694 - The 2010 Census Count Question Resolution Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-08

    ..., based on three types of challenges (1) boundary, (2) geocoding, and (3) coverage. The CQR Program is not... initial notice relating to the 2010 Census Count Question Resolution (CQR) Program (75 FR 29508). This... accept challenges between June 1, 2011, and June 1, 2013, and will review challenges in the order they...

  8. Geocode of River Networks in Global Plateaus

    NASA Astrophysics Data System (ADS)

    Ni, J.; Wang, Y.; Wang, T.

    2017-12-01

    As typical hierarchical systems, river networks are of great significance to aquatic organisms and its diversity. Different aspects of river networks have been investigated in previous studies such as network structure, formation cause, material transport, nutrient cycle and habitat variation. Nevertheless, river networks function as biological habitat is far from satisfactory in plateau areas. This paper presents a hierarchical method for habitat characterization of plateau river networks with the geocode extracted from abiotic factors including historical geologic period, climate zone, water source and geomorphic process at different spatial scales. As results, characteristics of biological response with vertical differentiation within typical plateau river networks are elucidated. Altitude, climate and landform are of great influence to habitat and thereby structure of aquatic community, while diverse water source and exogenic action would influence biological abundance or spatiotemporal distribution. Case studies are made in the main stream of the Yellow River and the Yangtze River, respectively extended to the river source to Qinghai-Tibet Plateau, which demonstrate high potentials for decision making support to river protection, ecological rehabilitation and sustainable management of river ecosystems.

  9. Spatializing 6,000 years of global urbanization from 3700 BC to AD 2000

    NASA Astrophysics Data System (ADS)

    Reba, Meredith; Reitsma, Femke; Seto, Karen C.

    2016-06-01

    How were cities distributed globally in the past? How many people lived in these cities? How did cities influence their local and regional environments? In order to understand the current era of urbanization, we must understand long-term historical urbanization trends and patterns. However, to date there is no comprehensive record of spatially explicit, historic, city-level population data at the global scale. Here, we developed the first spatially explicit dataset of urban settlements from 3700 BC to AD 2000, by digitizing, transcribing, and geocoding historical, archaeological, and census-based urban population data previously published in tabular form by Chandler and Modelski. The dataset creation process also required data cleaning and harmonization procedures to make the data internally consistent. Additionally, we created a reliability ranking for each geocoded location to assess the geographic uncertainty of each data point. The dataset provides the first spatially explicit archive of the location and size of urban populations over the last 6,000 years and can contribute to an improved understanding of contemporary and historical urbanization trends.

  10. Spatializing 6,000 years of global urbanization from 3700 BC to AD 2000

    PubMed Central

    Reba, Meredith; Reitsma, Femke; Seto, Karen C.

    2016-01-01

    How were cities distributed globally in the past? How many people lived in these cities? How did cities influence their local and regional environments? In order to understand the current era of urbanization, we must understand long-term historical urbanization trends and patterns. However, to date there is no comprehensive record of spatially explicit, historic, city-level population data at the global scale. Here, we developed the first spatially explicit dataset of urban settlements from 3700 BC to AD 2000, by digitizing, transcribing, and geocoding historical, archaeological, and census-based urban population data previously published in tabular form by Chandler and Modelski. The dataset creation process also required data cleaning and harmonization procedures to make the data internally consistent. Additionally, we created a reliability ranking for each geocoded location to assess the geographic uncertainty of each data point. The dataset provides the first spatially explicit archive of the location and size of urban populations over the last 6,000 years and can contribute to an improved understanding of contemporary and historical urbanization trends. PMID:27271481

  11. A simultaneously calibration approach for installation and attitude errors of an INS/GPS/LDS target tracker.

    PubMed

    Cheng, Jianhua; Chen, Daidai; Sun, Xiangyu; Wang, Tongda

    2015-02-04

    To obtain the absolute position of a target is one of the basic topics for non-cooperated target tracking problems. In this paper, we present a simultaneously calibration method for an Inertial navigation system (INS)/Global position system (GPS)/Laser distance scanner (LDS) integrated system based target positioning approach. The INS/GPS integrated system provides the attitude and position of observer, and LDS offers the distance between the observer and the target. The two most significant errors are taken into jointly consideration and analyzed: (1) the attitude measure error of INS/GPS; (2) the installation error between INS/GPS and LDS subsystems. Consequently, a INS/GPS/LDS based target positioning approach considering these two errors is proposed. In order to improve the performance of this approach, a novel calibration method is designed to simultaneously estimate and compensate these two main errors. Finally, simulations are conducted to access the performance of the proposed target positioning approach and the designed simultaneously calibration method.

  12. Proprioceptive deficit in individuals with unilateral tearing of the anterior cruciate ligament after active evaluation of the sense of joint position.

    PubMed

    Cossich, Victor; Mallrich, Frédéric; Titonelli, Victor; de Sousa, Eduardo Branco; Velasques, Bruna; Salles, José Inácio

    2014-01-01

    To ascertain whether the proprioceptive deficit in the sense of joint position continues to be present when patients with a limb presenting a deficient anterior cruciate ligament (ACL) are assessed by testing their active reproduction of joint position, in comparison with the contralateral limb. Twenty patients with unilateral ACL tearing participated in the study. Their active reproduction of joint position in the limb with the deficient ACL and in the healthy contralateral limb was tested. Meta-positions of 20% and 50% of the maximum joint range of motion were used. Proprioceptive performance was determined through the values of the absolute error, variable error and constant error. Significant differences in absolute error were found at both of the positions evaluated, and in constant error at 50% of the maximum joint range of motion. When evaluated in terms of absolute error, the proprioceptive deficit continues to be present even when an active evaluation of the sense of joint position is made. Consequently, this sense involves activity of both intramuscular and tendon receptors.

  13. The Frame Constraint on Experimentally Elicited Speech Errors in Japanese.

    PubMed

    Saito, Akie; Inoue, Tomoyoshi

    2017-06-01

    The so-called syllable position effect in speech errors has been interpreted as reflecting constraints posed by the frame structure of a given language, which is separately operating from linguistic content during speech production. The effect refers to the phenomenon that when a speech error occurs, replaced and replacing sounds tend to be in the same position within a syllable or word. Most of the evidence for the effect comes from analyses of naturally occurring speech errors in Indo-European languages, and there are few studies examining the effect in experimentally elicited speech errors and in other languages. This study examined whether experimentally elicited sound errors in Japanese exhibits the syllable position effect. In Japanese, the sub-syllabic unit known as "mora" is considered to be a basic sound unit in production. Results showed that the syllable position effect occurred in mora errors, suggesting that the frame constrains the ordering of sounds during speech production.

  14. A study protocol to evaluate the relationship between outdoor air pollution and pregnancy outcomes

    PubMed Central

    2010-01-01

    Background The present study protocol is designed to assess the relationship between outdoor air pollution and low birth weight and preterm births outcomes performing a semi-ecological analysis. Semi-ecological design studies are widely used to assess effects of air pollution in humans. In this type of analysis, health outcomes and covariates are measured in individuals and exposure assignments are usually based on air quality monitor stations. Therefore, estimating individual exposures are one of the major challenges when investigating these relationships with a semi-ecologic design. Methods/Design Semi-ecologic study consisting of a retrospective cohort study with ecologic assignment of exposure is applied. Health outcomes and covariates are collected at Primary Health Care Center. Data from pregnant registry, clinical record and specific questionnaire administered orally to the mothers of children born in period 2007-2010 in Portuguese Alentejo Litoral region, are collected by the research team. Outdoor air pollution data are collected with a lichen diversity biomonitoring program, and individual pregnancy exposures are assessed with spatial geostatistical simulation, which provides the basis for uncertainty analysis of individual exposures. Awareness of outdoor air pollution uncertainty will improve validity of individual exposures assignments for further statistical analysis with multivariate regression models. Discussion Exposure misclassification is an issue of concern in semi-ecological design. In this study, personal exposures are assigned to each pregnant using geocoded addresses data. A stochastic simulation method is applied to lichen diversity values index measured at biomonitoring survey locations, in order to assess spatial uncertainty of lichen diversity value index at each geocoded address. These methods assume a model for spatial autocorrelation of exposure and provide a distribution of exposures in each study location. We believe that variability of simulated exposure values at geocoded addresses will improve knowledge on variability of exposures, improving therefore validity of individual exposures to input in posterior statistical analysis. PMID:20950449

  15. Development of spatial density maps based on geoprocessing web services: application to tuberculosis incidence in Barcelona, Spain.

    PubMed

    Dominkovics, Pau; Granell, Carlos; Pérez-Navarro, Antoni; Casals, Martí; Orcau, Angels; Caylà, Joan A

    2011-11-29

    Health professionals and authorities strive to cope with heterogeneous data, services, and statistical models to support decision making on public health. Sophisticated analysis and distributed processing capabilities over geocoded epidemiological data are seen as driving factors to speed up control and decision making in these health risk situations. In this context, recent Web technologies and standards-based web services deployed on geospatial information infrastructures have rapidly become an efficient way to access, share, process, and visualize geocoded health-related information. Data used on this study is based on Tuberculosis (TB) cases registered in Barcelona city during 2009. Residential addresses are geocoded and loaded into a spatial database that acts as a backend database. The web-based application architecture and geoprocessing web services are designed according to the Representational State Transfer (REST) principles. These web processing services produce spatial density maps against the backend database. The results are focused on the use of the proposed web-based application to the analysis of TB cases in Barcelona. The application produces spatial density maps to ease the monitoring and decision making process by health professionals. We also include a discussion of how spatial density maps may be useful for health practitioners in such contexts. In this paper, we developed web-based client application and a set of geoprocessing web services to support specific health-spatial requirements. Spatial density maps of TB incidence were generated to help health professionals in analysis and decision-making tasks. The combined use of geographic information tools, map viewers, and geoprocessing services leads to interesting possibilities in handling health data in a spatial manner. In particular, the use of spatial density maps has been effective to identify the most affected areas and its spatial impact. This study is an attempt to demonstrate how web processing services together with web-based mapping capabilities suit the needs of health practitioners in epidemiological analysis scenarios.

  16. A study protocol to evaluate the relationship between outdoor air pollution and pregnancy outcomes.

    PubMed

    Ribeiro, Manuel C; Pereira, Maria J; Soares, Amílcar; Branquinho, Cristina; Augusto, Sofia; Llop, Esteve; Fonseca, Susana; Nave, Joaquim G; Tavares, António B; Dias, Carlos M; Silva, Ana; Selemane, Ismael; de Toro, Joaquin; Santos, Mário J; Santos, Fernanda

    2010-10-15

    The present study protocol is designed to assess the relationship between outdoor air pollution and low birth weight and preterm births outcomes performing a semi-ecological analysis. Semi-ecological design studies are widely used to assess effects of air pollution in humans. In this type of analysis, health outcomes and covariates are measured in individuals and exposure assignments are usually based on air quality monitor stations. Therefore, estimating individual exposures are one of the major challenges when investigating these relationships with a semi-ecologic design. Semi-ecologic study consisting of a retrospective cohort study with ecologic assignment of exposure is applied. Health outcomes and covariates are collected at Primary Health Care Center. Data from pregnant registry, clinical record and specific questionnaire administered orally to the mothers of children born in period 2007-2010 in Portuguese Alentejo Litoral region, are collected by the research team. Outdoor air pollution data are collected with a lichen diversity biomonitoring program, and individual pregnancy exposures are assessed with spatial geostatistical simulation, which provides the basis for uncertainty analysis of individual exposures. Awareness of outdoor air pollution uncertainty will improve validity of individual exposures assignments for further statistical analysis with multivariate regression models. Exposure misclassification is an issue of concern in semi-ecological design. In this study, personal exposures are assigned to each pregnant using geocoded addresses data. A stochastic simulation method is applied to lichen diversity values index measured at biomonitoring survey locations, in order to assess spatial uncertainty of lichen diversity value index at each geocoded address. These methods assume a model for spatial autocorrelation of exposure and provide a distribution of exposures in each study location. We believe that variability of simulated exposure values at geocoded addresses will improve knowledge on variability of exposures, improving therefore validity of individual exposures to input in posterior statistical analysis.

  17. Geotemporal Analysis of Neisseria meningitidis Clones in the United States: 2000–2005

    PubMed Central

    Wiringa, Ann E.; Shutt, Kathleen A.; Marsh, Jane W.; Cohn, Amanda C.; Messonnier, Nancy E.; Zansky, Shelley M.; Petit, Susan; Farley, Monica M.; Gershman, Ken; Lynfield, Ruth; Reingold, Arthur; Schaffner, William; Thompson, Jamie; Brown, Shawn T.; Lee, Bruce Y.; Harrison, Lee H.

    2013-01-01

    Background The detection of meningococcal outbreaks relies on serogrouping and epidemiologic definitions. Advances in molecular epidemiology have improved the ability to distinguish unique Neisseria meningitidis strains, enabling the classification of isolates into clones. Around 98% of meningococcal cases in the United States are believed to be sporadic. Methods Meningococcal isolates from 9 Active Bacterial Core surveillance sites throughout the United States from 2000 through 2005 were classified according to serogroup, multilocus sequence typing, and outer membrane protein (porA, porB, and fetA) genotyping. Clones were defined as isolates that were indistinguishable according to this characterization. Case data were aggregated to the census tract level and all non-singleton clones were assessed for non-random spatial and temporal clustering using retrospective space-time analyses with a discrete Poisson probability model. Results Among 1,062 geocoded cases with available isolates, 438 unique clones were identified, 78 of which had ≥2 isolates. 702 cases were attributable to non-singleton clones, accounting for 66.0% of all geocoded cases. 32 statistically significant clusters comprised of 107 cases (10.1% of all geocoded cases) were identified. Clusters had the following attributes: included 2 to 11 cases; 1 day to 33 months duration; radius of 0 to 61.7 km; and attack rate of 0.7 to 57.8 cases per 100,000 population. Serogroups represented among the clusters were: B (n = 12 clusters, 45 cases), C (n = 11 clusters, 27 cases), and Y (n = 9 clusters, 35 cases); 20 clusters (62.5%) were caused by serogroups represented in meningococcal vaccines that are commercially available in the United States. Conclusions Around 10% of meningococcal disease cases in the U.S. could be assigned to a geotemporal cluster. Molecular characterization of isolates, combined with geotemporal analysis, is a useful tool for understanding the spread of virulent meningococcal clones and patterns of transmission in populations. PMID:24349182

  18. Development of spatial density maps based on geoprocessing web services: application to tuberculosis incidence in Barcelona, Spain

    PubMed Central

    2011-01-01

    Background Health professionals and authorities strive to cope with heterogeneous data, services, and statistical models to support decision making on public health. Sophisticated analysis and distributed processing capabilities over geocoded epidemiological data are seen as driving factors to speed up control and decision making in these health risk situations. In this context, recent Web technologies and standards-based web services deployed on geospatial information infrastructures have rapidly become an efficient way to access, share, process, and visualize geocoded health-related information. Methods Data used on this study is based on Tuberculosis (TB) cases registered in Barcelona city during 2009. Residential addresses are geocoded and loaded into a spatial database that acts as a backend database. The web-based application architecture and geoprocessing web services are designed according to the Representational State Transfer (REST) principles. These web processing services produce spatial density maps against the backend database. Results The results are focused on the use of the proposed web-based application to the analysis of TB cases in Barcelona. The application produces spatial density maps to ease the monitoring and decision making process by health professionals. We also include a discussion of how spatial density maps may be useful for health practitioners in such contexts. Conclusions In this paper, we developed web-based client application and a set of geoprocessing web services to support specific health-spatial requirements. Spatial density maps of TB incidence were generated to help health professionals in analysis and decision-making tasks. The combined use of geographic information tools, map viewers, and geoprocessing services leads to interesting possibilities in handling health data in a spatial manner. In particular, the use of spatial density maps has been effective to identify the most affected areas and its spatial impact. This study is an attempt to demonstrate how web processing services together with web-based mapping capabilities suit the needs of health practitioners in epidemiological analysis scenarios. PMID:22126392

  19. Error modeling for differential GPS. M.S. Thesis - MIT, 12 May 1995

    NASA Technical Reports Server (NTRS)

    Blerman, Gregory S.

    1995-01-01

    Differential Global Positioning System (DGPS) positioning is used to accurately locate a GPS receiver based upon the well-known position of a reference site. In utilizing this technique, several error sources contribute to position inaccuracy. This thesis investigates the error in DGPS operation and attempts to develop a statistical model for the behavior of this error. The model for DGPS error is developed using GPS data collected by Draper Laboratory. The Marquardt method for nonlinear curve-fitting is used to find the parameters of a first order Markov process that models the average errors from the collected data. The results show that a first order Markov process can be used to model the DGPS error as a function of baseline distance and time delay. The model's time correlation constant is 3847.1 seconds (1.07 hours) for the mean square error. The distance correlation constant is 122.8 kilometers. The total process variance for the DGPS model is 3.73 sq meters.

  20. Statistical approaches to account for false-positive errors in environmental DNA samples.

    PubMed

    Lahoz-Monfort, José J; Guillera-Arroita, Gurutzeta; Tingley, Reid

    2016-05-01

    Environmental DNA (eDNA) sampling is prone to both false-positive and false-negative errors. We review statistical methods to account for such errors in the analysis of eDNA data and use simulations to compare the performance of different modelling approaches. Our simulations illustrate that even low false-positive rates can produce biased estimates of occupancy and detectability. We further show that removing or classifying single PCR detections in an ad hoc manner under the suspicion that such records represent false positives, as sometimes advocated in the eDNA literature, also results in biased estimation of occupancy, detectability and false-positive rates. We advocate alternative approaches to account for false-positive errors that rely on prior information, or the collection of ancillary detection data at a subset of sites using a sampling method that is not prone to false-positive errors. We illustrate the advantages of these approaches over ad hoc classifications of detections and provide practical advice and code for fitting these models in maximum likelihood and Bayesian frameworks. Given the severe bias induced by false-negative and false-positive errors, the methods presented here should be more routinely adopted in eDNA studies. © 2015 John Wiley & Sons Ltd.

  1. Servo control booster system for minimizing following error

    DOEpatents

    Wise, William L.

    1985-01-01

    A closed-loop feedback-controlled servo system is disclosed which reduces command-to-response error to the system's position feedback resolution least increment, .DELTA.S.sub.R, on a continuous real-time basis for all operating speeds. The servo system employs a second position feedback control loop on a by exception basis, when the command-to-response error .gtoreq..DELTA.S.sub.R, to produce precise position correction signals. When the command-to-response error is less than .DELTA.S.sub.R, control automatically reverts to conventional control means as the second position feedback control loop is disconnected, becoming transparent to conventional servo control means. By operating the second unique position feedback control loop used herein at the appropriate clocking rate, command-to-response error may be reduced to the position feedback resolution least increment. The present system may be utilized in combination with a tachometer loop for increased stability.

  2. Assessing explicit error reporting in the narrative electronic medical record using keyword searching.

    PubMed

    Cao, Hui; Stetson, Peter; Hripcsak, George

    2003-01-01

    Many types of medical errors occur in and outside of hospitals, some of which have very serious consequences and increase cost. Identifying errors is a critical step for managing and preventing them. In this study, we assessed the explicit reporting of medical errors in the electronic record. We used five search terms "mistake," "error," "incorrect," "inadvertent," and "iatrogenic" to survey several sets of narrative reports including discharge summaries, sign-out notes, and outpatient notes from 1991 to 2000. We manually reviewed all the positive cases and identified them based on the reporting of physicians. We identified 222 explicitly reported medical errors. The positive predictive value varied with different keywords. In general, the positive predictive value for each keyword was low, ranging from 3.4 to 24.4%. Therapeutic-related errors were the most common reported errors and these reported therapeutic-related errors were mainly medication errors. Keyword searches combined with manual review indicated some medical errors that were reported in medical records. It had a low sensitivity and a moderate positive predictive value, which varied by search term. Physicians were most likely to record errors in the Hospital Course and History of Present Illness sections of discharge summaries. The reported errors in medical records covered a broad range and were related to several types of care providers as well as non-health care professionals.

  3. Role-modeling and medical error disclosure: a national survey of trainees.

    PubMed

    Martinez, William; Hickson, Gerald B; Miller, Bonnie M; Doukas, David J; Buckley, John D; Song, John; Sehgal, Niraj L; Deitz, Jennifer; Braddock, Clarence H; Lehmann, Lisa Soleymani

    2014-03-01

    To measure trainees' exposure to negative and positive role-modeling for responding to medical errors and to examine the association between that exposure and trainees' attitudes and behaviors regarding error disclosure. Between May 2011 and June 2012, 435 residents at two large academic medical centers and 1,187 medical students from seven U.S. medical schools received anonymous, electronic questionnaires. The questionnaire asked respondents about (1) experiences with errors, (2) training for responding to errors, (3) behaviors related to error disclosure, (4) exposure to role-modeling for responding to errors, and (5) attitudes regarding disclosure. Using multivariate regression, the authors analyzed whether frequency of exposure to negative and positive role-modeling independently predicted two primary outcomes: (1) attitudes regarding disclosure and (2) nontransparent behavior in response to a harmful error. The response rate was 55% (884/1,622). Training on how to respond to errors had the largest independent, positive effect on attitudes (standardized effect estimate, 0.32, P < .001); negative role-modeling had the largest independent, negative effect (standardized effect estimate, -0.26, P < .001). Positive role-modeling had a positive effect on attitudes (standardized effect estimate, 0.26, P < .001). Exposure to negative role-modeling was independently associated with an increased likelihood of trainees' nontransparent behavior in response to an error (OR 1.37, 95% CI 1.15-1.64; P < .001). Exposure to role-modeling predicts trainees' attitudes and behavior regarding the disclosure of harmful errors. Negative role models may be a significant impediment to disclosure among trainees.

  4. Geodetic positioning using a global positioning system of satellites

    NASA Technical Reports Server (NTRS)

    Fell, P. J.

    1980-01-01

    Geodetic positioning using range, integrated Doppler, and interferometric observations from a constellation of twenty-four Global Positioning System satellites is analyzed. A summary of the proposals for geodetic positioning and baseline determination is given which includes a description of measurement techniques and comments on rank deficiency and error sources. An analysis of variance comparison of range, Doppler, and interferometric time delay to determine their relative geometric strength for baseline determination is included. An analytic examination to the effect of a priori constraints on positioning using simultaneous observations from two stations is presented. Dynamic point positioning and baseline determination using range and Doppler is examined in detail. Models for the error sources influencing dynamic positioning are developed. Included is a discussion of atomic clock stability, and range and Doppler observation error statistics based on random correlated atomic clock error are derived.

  5. Neural evidence for enhanced error detection in major depressive disorder.

    PubMed

    Chiu, Pearl H; Deldin, Patricia J

    2007-04-01

    Anomalies in error processing have been implicated in the etiology and maintenance of major depressive disorder. In particular, depressed individuals exhibit heightened sensitivity to error-related information and negative environmental cues, along with reduced responsivity to positive reinforcers. The authors examined the neural activation associated with error processing in individuals diagnosed with and without major depression and the sensitivity of these processes to modulation by monetary task contingencies. The error-related negativity and error-related positivity components of the event-related potential were used to characterize error monitoring in individuals with major depressive disorder and the degree to which these processes are sensitive to modulation by monetary reinforcement. Nondepressed comparison subjects (N=17) and depressed individuals (N=18) performed a flanker task under two external motivation conditions (i.e., monetary reward for correct responses and monetary loss for incorrect responses) and a nonmonetary condition. After each response, accuracy feedback was provided. The error-related negativity component assessed the degree of anomaly in initial error detection, and the error positivity component indexed recognition of errors. Across all conditions, the depressed participants exhibited greater amplitude of the error-related negativity component, relative to the comparison subjects, and equivalent error positivity amplitude. In addition, the two groups showed differential modulation by task incentives in both components. These data implicate exaggerated early error-detection processes in the etiology and maintenance of major depressive disorder. Such processes may then recruit excessive neural and cognitive resources that manifest as symptoms of depression.

  6. Parolees' Physical Closeness to Social Services: A Study of California Parolees

    ERIC Educational Resources Information Center

    Hipp, John R.; Jannetta, Jesse; Shah, Rita; Turner, Susan

    2011-01-01

    This study examines the proximity of service providers to recently released parolees in California over a 2-year period (2005-2006). The addresses of parolee residences and service providers are geocoded, and the number of various types of service providers within 2 miles (3.2 km) of a parolee are measured. "Potential demand" is measured…

  7. Labor Market Frictions and Production Efficiency in Public Schools. Working Paper 163

    ERIC Educational Resources Information Center

    Kim, Dongwoo; Koedel, Cory; Ni, Shawn; Podgursky, Michael

    2016-01-01

    State-specific licensing policies and pension plans create mobility costs for educators who cross state lines. We empirically test whether these costs affect production in schools--a hypothesis that follows directly from economic theory on labor frictions--using geo-coded data from the lower-48 states. We find that achievement is lower in…

  8. Urban trees and the risk of poor birth outcomes

    Treesearch

    Geoffrey H. Donovan; Yvonne L. Michael; David T. Butry; Amy D. Sullivan; John M. Chase

    2011-01-01

    This paper investigated whether greater tree-canopy cover is associated with reduced risk of poor birth outcomes in Portland, Oregon. Residential addresses were geocoded and linked to classified-aerial imagery to calculate tree-canopy cover in 50, 100, and 200 m buffers around each home in our sample (n=5696). Detailed data on maternal characteristics and additional...

  9. Rural and Urban High School Dropout Rates: Are They Different?

    ERIC Educational Resources Information Center

    Jordan, Jeffrey L.; Kostandini, Genti; Mykerezi, Elton

    2012-01-01

    This study estimates the high school dropout rate in rural and urban areas, the determinants of dropping out, and whether the differences in graduation rates have changed over time. We use geocoded data from two nationally representative panel household surveys (NLSY 97 and NLSY 79) and a novel methodology that corrects for biases in graduation…

  10. Indicators of Access to Early Childhood Services in the Mississippi Delta. Rural Early Childhood Report No. 5

    ERIC Educational Resources Information Center

    Shores, Elizabeth F.; Barbaro, Erin; Barbaro, Michael C.; Flenner, Michelle; Bell, Lynn

    2007-01-01

    The Early Childhood Atlas facilitates spatial analysis in early childhood services research for the promotion of greater quality and accessibility of early care and education. The Atlas team collects and geocodes federal, state and nongovernmental datasets about early childhood services, integrating selected data elements into its online mapmaking…

  11. 77 FR 9956 - Announcement of Funding Awards for the Sustainable Communities Regional Planning Grant Program...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-21

    ... of regional significance, use data to set and monitor progress toward performance goals, and engage... Principles; d. Use geo-coded data sets and other metrics in developing, implementing, monitoring, and... (103 Stat. 1987, 42 U.S.C. 3545), the Department is publishing the names, addresses, and amounts of the...

  12. Research on correction algorithm of laser positioning system based on four quadrant detector

    NASA Astrophysics Data System (ADS)

    Gao, Qingsong; Meng, Xiangyong; Qian, Weixian; Cai, Guixia

    2018-02-01

    This paper first introduces the basic principle of the four quadrant detector, and a set of laser positioning experiment system is built based on the four quadrant detector. Four quadrant laser positioning system in the actual application, not only exist interference of background light and detector dark current noise, and the influence of random noise, system stability, spot equivalent error can't be ignored, so it is very important to system calibration and correction. This paper analyzes the various factors of system positioning error, and then propose an algorithm for correcting the system error, the results of simulation and experiment show that the modified algorithm can improve the effect of system error on positioning and improve the positioning accuracy.

  13. Generalized site occupancy models allowing for false positive and false negative errors

    USGS Publications Warehouse

    Royle, J. Andrew; Link, W.A.

    2006-01-01

    Site occupancy models have been developed that allow for imperfect species detection or ?false negative? observations. Such models have become widely adopted in surveys of many taxa. The most fundamental assumption underlying these models is that ?false positive? errors are not possible. That is, one cannot detect a species where it does not occur. However, such errors are possible in many sampling situations for a number of reasons, and even low false positive error rates can induce extreme bias in estimates of site occupancy when they are not accounted for. In this paper, we develop a model for site occupancy that allows for both false negative and false positive error rates. This model can be represented as a two-component finite mixture model and can be easily fitted using freely available software. We provide an analysis of avian survey data using the proposed model and present results of a brief simulation study evaluating the performance of the maximum-likelihood estimator and the naive estimator in the presence of false positive errors.

  14. Synchronization Design and Error Analysis of Near-Infrared Cameras in Surgical Navigation.

    PubMed

    Cai, Ken; Yang, Rongqian; Chen, Huazhou; Huang, Yizhou; Wen, Xiaoyan; Huang, Wenhua; Ou, Shanxing

    2016-01-01

    The accuracy of optical tracking systems is important to scientists. With the improvements reported in this regard, such systems have been applied to an increasing number of operations. To enhance the accuracy of these systems further and to reduce the effect of synchronization and visual field errors, this study introduces a field-programmable gate array (FPGA)-based synchronization control method, a method for measuring synchronous errors, and an error distribution map in field of view. Synchronization control maximizes the parallel processing capability of FPGA, and synchronous error measurement can effectively detect the errors caused by synchronization in an optical tracking system. The distribution of positioning errors can be detected in field of view through the aforementioned error distribution map. Therefore, doctors can perform surgeries in areas with few positioning errors, and the accuracy of optical tracking systems is considerably improved. The system is analyzed and validated in this study through experiments that involve the proposed methods, which can eliminate positioning errors attributed to asynchronous cameras and different fields of view.

  15. An IMU-Aided Body-Shadowing Error Compensation Method for Indoor Bluetooth Positioning

    PubMed Central

    Deng, Zhongliang

    2018-01-01

    Research on indoor positioning technologies has recently become a hotspot because of the huge social and economic potential of indoor location-based services (ILBS). Wireless positioning signals have a considerable attenuation in received signal strength (RSS) when transmitting through human bodies, which would cause significant ranging and positioning errors in RSS-based systems. This paper mainly focuses on the body-shadowing impairment of RSS-based ranging and positioning, and derives a mathematical expression of the relation between the body-shadowing effect and the positioning error. In addition, an inertial measurement unit-aided (IMU-aided) body-shadowing detection strategy is designed, and an error compensation model is established to mitigate the effect of body-shadowing. A Bluetooth positioning algorithm with body-shadowing error compensation (BP-BEC) is then proposed to improve both the positioning accuracy and the robustness in indoor body-shadowing environments. Experiments are conducted in two indoor test beds, and the performance of both the BP-BEC algorithm and the algorithms without body-shadowing error compensation (named no-BEC) is evaluated. The results show that the BP-BEC outperforms the no-BEC by about 60.1% and 73.6% in terms of positioning accuracy and robustness, respectively. Moreover, the execution time of the BP-BEC algorithm is also evaluated, and results show that the convergence speed of the proposed algorithm has an insignificant effect on real-time localization. PMID:29361718

  16. An IMU-Aided Body-Shadowing Error Compensation Method for Indoor Bluetooth Positioning.

    PubMed

    Deng, Zhongliang; Fu, Xiao; Wang, Hanhua

    2018-01-20

    Research on indoor positioning technologies has recently become a hotspot because of the huge social and economic potential of indoor location-based services (ILBS). Wireless positioning signals have a considerable attenuation in received signal strength (RSS) when transmitting through human bodies, which would cause significant ranging and positioning errors in RSS-based systems. This paper mainly focuses on the body-shadowing impairment of RSS-based ranging and positioning, and derives a mathematical expression of the relation between the body-shadowing effect and the positioning error. In addition, an inertial measurement unit-aided (IMU-aided) body-shadowing detection strategy is designed, and an error compensation model is established to mitigate the effect of body-shadowing. A Bluetooth positioning algorithm with body-shadowing error compensation (BP-BEC) is then proposed to improve both the positioning accuracy and the robustness in indoor body-shadowing environments. Experiments are conducted in two indoor test beds, and the performance of both the BP-BEC algorithm and the algorithms without body-shadowing error compensation (named no-BEC) is evaluated. The results show that the BP-BEC outperforms the no-BEC by about 60.1% and 73.6% in terms of positioning accuracy and robustness, respectively. Moreover, the execution time of the BP-BEC algorithm is also evaluated, and results show that the convergence speed of the proposed algorithm has an insignificant effect on real-time localization.

  17. Error framing effects on performance: cognitive, motivational, and affective pathways.

    PubMed

    Steele-Johnson, Debra; Kalinoski, Zachary T

    2014-01-01

    Our purpose was to examine whether positive error framing, that is, making errors salient and cuing individuals to see errors as useful, can benefit learning when task exploration is constrained. Recent research has demonstrated the benefits of a newer approach to training, that is, error management training, that includes the opportunity to actively explore the task and framing errors as beneficial to learning complex tasks (Keith & Frese, 2008). Other research has highlighted the important role of errors in on-the-job learning in complex domains (Hutchins, 1995). Participants (N = 168) from a large undergraduate university performed a class scheduling task. Results provided support for a hypothesized path model in which error framing influenced cognitive, motivational, and affective factors which in turn differentially affected performance quantity and quality. Within this model, error framing had significant direct effects on metacognition and self-efficacy. Our results suggest that positive error framing can have beneficial effects even when tasks cannot be structured to support extensive exploration. Whereas future research can expand our understanding of error framing effects on outcomes, results from the current study suggest that positive error framing can facilitate learning from errors in real-time performance of tasks.

  18. Servo control booster system for minimizing following error

    DOEpatents

    Wise, W.L.

    1979-07-26

    A closed-loop feedback-controlled servo system is disclosed which reduces command-to-response error to the system's position feedback resolution least increment, ..delta..S/sub R/, on a continuous real-time basis, for all operational times of consequence and for all operating speeds. The servo system employs a second position feedback control loop on a by exception basis, when the command-to-response error greater than or equal to ..delta..S/sub R/, to produce precise position correction signals. When the command-to-response error is less than ..delta..S/sub R/, control automatically reverts to conventional control means as the second position feedback control loop is disconnected, becoming transparent to conventional servo control means. By operating the second unique position feedback control loop used herein at the appropriate clocking rate, command-to-response error may be reduced to the position feedback resolution least increment. The present system may be utilized in combination with a tachometer loop for increased stability.

  19. False Positives in Multiple Regression: Unanticipated Consequences of Measurement Error in the Predictor Variables

    ERIC Educational Resources Information Center

    Shear, Benjamin R.; Zumbo, Bruno D.

    2013-01-01

    Type I error rates in multiple regression, and hence the chance for false positive research findings, can be drastically inflated when multiple regression models are used to analyze data that contain random measurement error. This article shows the potential for inflated Type I error rates in commonly encountered scenarios and provides new…

  20. An Upper Bound on Orbital Debris Collision Probability When Only One Object has Position Uncertainty Information

    NASA Technical Reports Server (NTRS)

    Frisbee, Joseph H., Jr.

    2015-01-01

    Upper bounds on high speed satellite collision probability, P (sub c), have been investigated. Previous methods assume an individual position error covariance matrix is available for each object. The two matrices being combined into a single, relative position error covariance matrix. Components of the combined error covariance are then varied to obtain a maximum P (sub c). If error covariance information for only one of the two objects was available, either some default shape has been used or nothing could be done. An alternative is presented that uses the known covariance information along with a critical value of the missing covariance to obtain an approximate but useful P (sub c) upper bound. There are various avenues along which an upper bound on the high speed satellite collision probability has been pursued. Typically, for the collision plane representation of the high speed collision probability problem, the predicted miss position in the collision plane is assumed fixed. Then the shape (aspect ratio of ellipse), the size (scaling of standard deviations) or the orientation (rotation of ellipse principal axes) of the combined position error ellipse is varied to obtain a maximum P (sub c). Regardless as to the exact details of the approach, previously presented methods all assume that an individual position error covariance matrix is available for each object and the two are combined into a single, relative position error covariance matrix. This combined position error covariance matrix is then modified according to the chosen scheme to arrive at a maximum P (sub c). But what if error covariance information for one of the two objects is not available? When error covariance information for one of the objects is not available the analyst has commonly defaulted to the situation in which only the relative miss position and velocity are known without any corresponding state error covariance information. The various usual methods of finding a maximum P (sub c) do no good because the analyst defaults to no knowledge of the combined, relative position error covariance matrix. It is reasonable to think, given an assumption of no covariance information, an analyst might still attempt to determine the error covariance matrix that results in an upper bound on the P (sub c). Without some guidance on limits to the shape, size and orientation of the unknown covariance matrix, the limiting case is a degenerate ellipse lying along the relative miss vector in the collision plane. Unless the miss position is exceptionally large or the at-risk object is exceptionally small, this method results in a maximum P (sub c) too large to be of practical use. For example, assuming that the miss distance is equal to the current ISS alert volume along-track (+ or -) distance of 25 kilometers and that the at-risk area has a 70 meter radius. The maximum (degenerate ellipse) P (sub c) is about 0.00136. At 40 kilometers, the maximum P (sub c) would be 0.00085 which is still almost an order of magnitude larger than the ISS maneuver threshold of 0.0001. In fact, a miss distance of almost 340 kilometers is necessary to reduce the maximum P (sub c) associated with this degenerate ellipse to the ISS maneuver threshold value. Such a result is frequently of no practical value to the analyst. Some improvement may be made with respect to this problem by realizing that while the position error covariance matrix of one of the objects (usually the debris object) may not be known the position error covariance matrix of the other object (usually the asset) is almost always available. Making use of the position error covariance information for the one object provides an improvement in finding a maximum P (sub c) which, in some cases, may offer real utility. The equations to be used are presented and their use discussed.

  1. Bolus-dependent dosimetric effect of positioning errors for tangential scalp radiotherapy with helical tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lobb, Eric, E-mail: eclobb2@gmail.com

    2014-04-01

    The dosimetric effect of errors in patient position is studied on-phantom as a function of simulated bolus thickness to assess the need for bolus utilization in scalp radiotherapy with tomotherapy. A treatment plan is generated on a cylindrical phantom, mimicking a radiotherapy technique for the scalp utilizing primarily tangential beamlets. A planning target volume with embedded scalplike clinical target volumes (CTVs) is planned to a uniform dose of 200 cGy. Translational errors in phantom position are introduced in 1-mm increments and dose is recomputed from the original sinogram. For each error the maximum dose, minimum dose, clinical target dose homogeneitymore » index (HI), and dose-volume histogram (DVH) are presented for simulated bolus thicknesses from 0 to 10 mm. Baseline HI values for all bolus thicknesses were in the 5.5 to 7.0 range, increasing to a maximum of 18.0 to 30.5 for the largest positioning errors when 0 to 2 mm of bolus is used. Utilizing 5 mm of bolus resulted in a maximum HI value of 9.5 for the largest positioning errors. Using 0 to 2 mm of bolus resulted in minimum and maximum dose values of 85% to 94% and 118% to 125% of the prescription dose, respectively. When using 5 mm of bolus these values were 98.5% and 109.5%. DVHs showed minimal changes in CTV dose coverage when using 5 mm of bolus, even for the largest positioning errors. CTV dose homogeneity becomes increasingly sensitive to errors in patient position as bolus thickness decreases when treating the scalp with primarily tangential beamlets. Performing a radial expansion of the scalp CTV into 5 mm of bolus material minimizes dosimetric sensitivity to errors in patient position as large as 5 mm and is therefore recommended.« less

  2. WE-H-BRC-05: Catastrophic Error Metrics for Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, S; Molloy, J

    Purpose: Intuitive evaluation of complex radiotherapy treatments is impractical, while data transfer anomalies create the potential for catastrophic treatment delivery errors. Contrary to prevailing wisdom, logical scrutiny can be applied to patient-specific machine settings. Such tests can be automated, applied at the point of treatment delivery and can be dissociated from prior states of the treatment plan, potentially revealing errors introduced early in the process. Methods: Analytical metrics were formulated for conventional and intensity modulated RT (IMRT) treatments. These were designed to assess consistency between monitor unit settings, wedge values, prescription dose and leaf positioning (IMRT). Institutional metric averages formore » 218 clinical plans were stratified over multiple anatomical sites. Treatment delivery errors were simulated using a commercial treatment planning system and metric behavior assessed via receiver-operator-characteristic (ROC) analysis. A positive result was returned if the erred plan metric value exceeded a given number of standard deviations, e.g. 2. The finding was declared true positive if the dosimetric impact exceeded 25%. ROC curves were generated over a range of metric standard deviations. Results: Data for the conventional treatment metric indicated standard deviations of 3%, 12%, 11%, 8%, and 5 % for brain, pelvis, abdomen, lung and breast sites, respectively. Optimum error declaration thresholds yielded true positive rates (TPR) between 0.7 and 1, and false positive rates (FPR) between 0 and 0.2. Two proposed IMRT metrics possessed standard deviations of 23% and 37%. The superior metric returned TPR and FPR of 0.7 and 0.2, respectively, when both leaf position and MUs were modelled. Isolation to only leaf position errors yielded TPR and FPR values of 0.9 and 0.1. Conclusion: Logical tests can reveal treatment delivery errors and prevent large, catastrophic errors. Analytical metrics are able to identify errors in monitor units, wedging and leaf positions with favorable sensitivity and specificity. In part by Varian.« less

  3. Dizziness and unsteadiness following whiplash injury: characteristic features and relationship with cervical joint position error.

    PubMed

    Treleaven, Julia; Jull, Gwendolen; Sterling, Michele

    2003-01-01

    Dizziness and/or unsteadiness are common symptoms of chronic whiplash-associated disorders. This study aimed to report the characteristics of these symptoms and determine whether there was any relationship to cervical joint position error. Joint position error, the accuracy to return to the natural head posture following extension and rotation, was measured in 102 subjects with persistent whiplash-associated disorder and 44 control subjects. Whiplash subjects completed a neck pain index and answered questions about the characteristics of dizziness. The results indicated that subjects with whiplash-associated disorders had significantly greater joint position errors than control subjects. Within the whiplash group, those with dizziness had greater joint position errors than those without dizziness following rotation (rotation (R) 4.5 degrees (0.3) vs 2.9 degrees (0.4); rotation (L) 3.9 degrees (0.3) vs 2.8 degrees (0.4) respectively) and a higher neck pain index (55.3% (1.4) vs 43.1% (1.8)). Characteristics of the dizziness were consistent for those reported for a cervical cause but no characteristics could predict the magnitude of joint position error. Cervical mechanoreceptor dysfunction is a likely cause of dizziness in whiplash-associated disorder.

  4. Neighborhood Reputation and Resident Sentiment in the Wake of the Las Vegas Foreclosure Crisis

    PubMed Central

    Pais, Jeremy; Batson, Christie D.; Monnat, Shannon M.

    2014-01-01

    This study examines how two major components of a neighborhood’s reputation—perceived disorder and collective efficacy—shape individuals’ sentiments toward their neighborhoods during the foreclosure crisis triggered by the Great Recession. Of central interest are whether neighborhood reputations are durable in the face of a crisis (neighborhood resiliency hypothesis) or whether neighborhood reputations wane during times of duress (foreclosure crisis hypothesis). Geo-coded individual-level data from the Las Vegas Metropolitan Area Social Survey merged with data on census tract foreclosure rates are used to address this question. The results provide qualified support for both perspectives. In support of the neighborhood resiliency hypothesis, collective efficacy is positively associated with how residents feel about the quality of their neighborhoods, and this relationship is unaltered by foreclosure rates. In support of the foreclosure crisis hypothesis, foreclosure rates mediate the effects of neighborhood disorder on resident sentiment. The implications of these findings for community resiliency are discussed. PMID:25678735

  5. Associations of ozone and PM2.5 concentrations with Parkinson’s disease among participants in the Agricultural Health Study

    PubMed Central

    Bowman, Christal; Davis, J. Allen; Hoppin, Jane A.; Blair, Aaron; Chen, Honglei; Patel, Molini M.; Sandler, Dale P.; Tanner, Caroline M.; Vinikoor-Imler, Lisa; Ward, Mary H.; Luben, Thomas J.; Kamel, Freya

    2015-01-01

    Objective This study describes associations of ozone and fine particulate matter with Parkinson’s disease observed among farmers in North Carolina and Iowa. Methods We used logistic regression to determine the associations of these pollutants with self-reported, doctor-diagnosed Parkinson’s disease. Daily predicted pollutant concentrations were used to derive surrogates of long-term exposure and link them to study participants’ geocoded addresses. Results We observed positive associations of Parkinson’s disease with ozone (OR=1.39; 95% CI: 0.98, 1.98) and fine particulate matter (OR=1.34; 95% CI: 0.93, 1.93) in North Carolina but not in Iowa. Conclusion The plausibility of an effect of ambient concentrations of these pollutants on Parkinson’s disease risk is supported by experimental data demonstrating damage to dopaminergic neurons at relevant concentrations. Additional studies are needed to address uncertainties related to confounding and to examine temporal aspects of the associations we observed. PMID:25951420

  6. Accounting for autocorrelation in multi-drug resistant tuberculosis predictors using a set of parsimonious orthogonal eigenvectors aggregated in geographic space.

    PubMed

    Jacob, Benjamin J; Krapp, Fiorella; Ponce, Mario; Gottuzzo, Eduardo; Griffith, Daniel A; Novak, Robert J

    2010-05-01

    Spatial autocorrelation is problematic for classical hierarchical cluster detection tests commonly used in multi-drug resistant tuberculosis (MDR-TB) analyses as considerable random error can occur. Therefore, when MDRTB clusters are spatially autocorrelated the assumption that the clusters are independently random is invalid. In this research, a product moment correlation coefficient (i.e., the Moran's coefficient) was used to quantify local spatial variation in multiple clinical and environmental predictor variables sampled in San Juan de Lurigancho, Lima, Peru. Initially, QuickBird 0.61 m data, encompassing visible bands and the near infra-red bands, were selected to synthesize images of land cover attributes of the study site. Data of residential addresses of individual patients with smear-positive MDR-TB were geocoded, prevalence rates calculated and then digitally overlaid onto the satellite data within a 2 km buffer of 31 georeferenced health centers, using a 10 m2 grid-based algorithm. Geographical information system (GIS)-gridded measurements of each health center were generated based on preliminary base maps of the georeferenced data aggregated to block groups and census tracts within each buffered area. A three-dimensional model of the study site was constructed based on a digital elevation model (DEM) to determine terrain covariates associated with the sampled MDR-TB covariates. Pearson's correlation was used to evaluate the linear relationship between the DEM and the sampled MDR-TB data. A SAS/GIS(R) module was then used to calculate univariate statistics and to perform linear and non-linear regression analyses using the sampled predictor variables. The estimates generated from a global autocorrelation analyses were then spatially decomposed into empirical orthogonal bases using a negative binomial regression with a non-homogeneous mean. Results of the DEM analyses indicated a statistically non-significant, linear relationship between georeferenced health centers and the sampled covariate elevation. The data exhibited positive spatial autocorrelation and the decomposition of Moran's coefficient into uncorrelated, orthogonal map pattern components revealed global spatial heterogeneities necessary to capture latent autocorrelation in the MDR-TB model. It was thus shown that Poisson regression analyses and spatial eigenvector mapping can elucidate the mechanics of MDR-TB transmission by prioritizing clinical and environmental-sampled predictor variables for identifying high risk populations.

  7. Quality assurance of dynamic parameters in volumetric modulated arc therapy.

    PubMed

    Manikandan, A; Sarkar, B; Holla, R; Vivek, T R; Sujatha, N

    2012-07-01

    The purpose of this study was to demonstrate quality assurance checks for accuracy of gantry speed and position, dose rate and multileaf collimator (MLC) speed and position for a volumetric modulated arc treatment (VMAT) modality (Synergy S; Elekta, Stockholm, Sweden), and to check that all the necessary variables and parameters were synchronous. Three tests (for gantry position-dose delivery synchronisation, gantry speed-dose delivery synchronisation and MLC leaf speed and positions) were performed. The average error in gantry position was 0.5° and the average difference was 3 MU for a linear and a parabolic relationship between gantry position and delivered dose. In the third part of this test (sawtooth variation), the maximum difference was 9.3 MU, with a gantry position difference of 1.2°. In the sweeping field method test, a linear relationship was observed between recorded doses and distance from the central axis, as expected. In the open field method, errors were encountered at the beginning and at the end of the delivery arc, termed the "beginning" and "end" errors. For MLC position verification, the maximum error was -2.46 mm and the mean error was 0.0153 ±0.4668 mm, and 3.4% of leaves analysed showed errors of >±1 mm. This experiment demonstrates that the variables and parameters of the Synergy S are synchronous and that the system is suitable for delivering VMAT using a dynamic MLC.

  8. A high-accuracy two-position alignment inertial navigation system for lunar rovers aided by a star sensor with a calibration and positioning function

    NASA Astrophysics Data System (ADS)

    Lu, Jiazhen; Lei, Chaohua; Yang, Yanqiang; Liu, Ming

    2016-12-01

    An integrated inertial/celestial navigation system (INS/CNS) has wide applicability in lunar rovers as it provides accurate and autonomous navigational information. Initialization is particularly vital for a INS. This paper proposes a two-position initialization method based on a standard Kalman filter. The difference between the computed star vector and the measured star vector is measured. With the aid of a star sensor and the two positions, the attitudinal and positional errors can be greatly reduced, and the biases of three gyros and accelerometers can also be estimated. The semi-physical simulation results show that the positional and attitudinal errors converge within 0.07″ and 0.1 m, respectively, when the given initial positional error is 1 km and the attitudinal error is 10°. These good results show that the proposed method can accomplish alignment, positioning and calibration functions simultaneously. Thus the proposed two-position initialization method has the potential for application in lunar rover navigation.

  9. ERROR COMPENSATOR FOR A POSITION TRANSDUCER

    DOEpatents

    Fowler, A.H.

    1962-06-12

    A device is designed for eliminating the effect of leadscrew errors in positioning machines in which linear motion of a slide is effected from rotary motion of a leadscrew. This is accomplished by providing a corrector cam mounted on the slide, a cam follower, and a transducer housing rotatable by the follower to compensate for all the reproducible errors in the transducer signal which can be related to the slide position. The transducer has an inner part which is movable with respect to the transducer housing. The transducer inner part is coupled to the means for rotating the leadscrew such that relative movement between this part and its housing will provide an output signal proportional to the position of the slide. The corrector cam and its follower perform the compensation by changing the angular position of the transducer housing by an amount that is a function of the slide position and the error at that position. (AEC)

  10. Rural and Urban Differences in the Associations between Characteristics of the Community Food Environment and Fruit and Vegetable Intake

    ERIC Educational Resources Information Center

    Dean, Wesley R.; Sharkey, Joseph R.

    2011-01-01

    Objective: To examine the relationship between measures of the household and retail food environments and fruit and vegetable (FV) intake in both urban and rural environmental contexts. Design: A cross-sectional design was used. Data for FV intake and other characteristics were collected via survey instrument and geocoded to the objective food…

  11. Review of "The Effect of Milwaukee's Parental Choice Program on Student Achievement in Milwaukee Public Schools"

    ERIC Educational Resources Information Center

    Camilli, Gregory

    2009-01-01

    According to a new study of Milwaukee public schools, student achievement has benefited from voucher-based school competition. A novel method, using geocoding, was proposed for measuring the degree of competition within the city of Milwaukee and, in turn, for determining whether such competition has increased or decreased the achievement of public…

  12. 76 FR 66950 - Privacy Act; Notice of Revision of System of Records, the Single Family Housing Enterprise Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-28

    ... Management System (SAMS) 6. F17--Computerized Home Underwriting Mortgage System (CHUMS) 7. F42D--Single... Federal Reserve Board (FRB) 14. F71A--Generic Debt Management System (GDEBT) 15. A15--Geocoding Service... Revision of System of Records, the Single Family Housing Enterprise Data Warehouse AGENCY: Office of the...

  13. 78 FR 48912 - Agency Information Collection Activities: Submission to OMB for Reinstatement, With, of a...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-12

    ... for analysis in the NCUA Low-Income Designation (LID) Tool. The LID Tool is a geocoding software... the member address data are obtained through the examination process and the results of the LID Tool... may send an electronic member address data file for analysis in the LID Tool. If a credit union does...

  14. 78 FR 59377 - Agency Information Collection Activities: Submission to OMB for Reinstatement, With Change, of a...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-26

    ... analysis in the NCUA Low-Income Designation (LID) Tool. The LID Tool is a geocoding software program which... data are obtained through the examination process and the results of the LID Tool indicate the credit... electronic member address data file for analysis in the LID Tool. If a credit union does not qualify for a...

  15. Gis-Based Spatial Statistical Analysis of College Graduates Employment

    NASA Astrophysics Data System (ADS)

    Tang, R.

    2012-07-01

    It is urgently necessary to be aware of the distribution and employment status of college graduates for proper allocation of human resources and overall arrangement of strategic industry. This study provides empirical evidence regarding the use of geocoding and spatial analysis in distribution and employment status of college graduates based on the data from 2004-2008 Wuhan Municipal Human Resources and Social Security Bureau, China. Spatio-temporal distribution of employment unit were analyzed with geocoding using ArcGIS software, and the stepwise multiple linear regression method via SPSS software was used to predict the employment and to identify spatially associated enterprise and professionals demand in the future. The results show that the enterprises in Wuhan east lake high and new technology development zone increased dramatically from 2004 to 2008, and tended to distributed southeastward. Furthermore, the models built by statistical analysis suggest that the specialty of graduates major in has an important impact on the number of the employment and the number of graduates engaging in pillar industries. In conclusion, the combination of GIS and statistical analysis which helps to simulate the spatial distribution of the employment status is a potential tool for human resource development research.

  16. Disclosure of Medical Errors: What Factors Influence How Patients Respond?

    PubMed Central

    Mazor, Kathleen M; Reed, George W; Yood, Robert A; Fischer, Melissa A; Baril, Joann; Gurwitz, Jerry H

    2006-01-01

    BACKGROUND Disclosure of medical errors is encouraged, but research on how patients respond to specific practices is limited. OBJECTIVE This study sought to determine whether full disclosure, an existing positive physician-patient relationship, an offer to waive associated costs, and the severity of the clinical outcome influenced patients' responses to medical errors. PARTICIPANTS Four hundred and seven health plan members participated in a randomized experiment in which they viewed video depictions of medical error and disclosure. DESIGN Subjects were randomly assigned to experimental condition. Conditions varied in type of medication error, level of disclosure, reference to a prior positive physician-patient relationship, an offer to waive costs, and clinical outcome. MEASURES Self-reported likelihood of changing physicians and of seeking legal advice; satisfaction, trust, and emotional response. RESULTS Nondisclosure increased the likelihood of changing physicians, and reduced satisfaction and trust in both error conditions. Nondisclosure increased the likelihood of seeking legal advice and was associated with a more negative emotional response in the missed allergy error condition, but did not have a statistically significant impact on seeking legal advice or emotional response in the monitoring error condition. Neither the existence of a positive relationship nor an offer to waive costs had a statistically significant impact. CONCLUSIONS This study provides evidence that full disclosure is likely to have a positive effect or no effect on how patients respond to medical errors. The clinical outcome also influences patients' responses. The impact of an existing positive physician-patient relationship, or of waiving costs associated with the error remains uncertain. PMID:16808770

  17. Compensation for positioning error of industrial robot for flexible vision measuring system

    NASA Astrophysics Data System (ADS)

    Guo, Lei; Liang, Yajun; Song, Jincheng; Sun, Zengyu; Zhu, Jigui

    2013-01-01

    Positioning error of robot is a main factor of accuracy of flexible coordinate measuring system which consists of universal industrial robot and visual sensor. Present compensation methods for positioning error based on kinematic model of robot have a significant limitation that it isn't effective in the whole measuring space. A new compensation method for positioning error of robot based on vision measuring technique is presented. One approach is setting global control points in measured field and attaching an orientation camera to vision sensor. Then global control points are measured by orientation camera to calculate the transformation relation from the current position of sensor system to global coordinate system and positioning error of robot is compensated. Another approach is setting control points on vision sensor and two large field cameras behind the sensor. Then the three dimensional coordinates of control points are measured and the pose and position of sensor is calculated real-timely. Experiment result shows the RMS of spatial positioning is 3.422mm by single camera and 0.031mm by dual cameras. Conclusion is arithmetic of single camera method needs to be improved for higher accuracy and accuracy of dual cameras method is applicable.

  18. Reward positivity: Reward prediction error or salience prediction error?

    PubMed

    Heydari, Sepideh; Holroyd, Clay B

    2016-08-01

    The reward positivity is a component of the human ERP elicited by feedback stimuli in trial-and-error learning and guessing tasks. A prominent theory holds that the reward positivity reflects a reward prediction error signal that is sensitive to outcome valence, being larger for unexpected positive events relative to unexpected negative events (Holroyd & Coles, 2002). Although the theory has found substantial empirical support, most of these studies have utilized either monetary or performance feedback to test the hypothesis. However, in apparent contradiction to the theory, a recent study found that unexpected physical punishments also elicit the reward positivity (Talmi, Atkinson, & El-Deredy, 2013). The authors of this report argued that the reward positivity reflects a salience prediction error rather than a reward prediction error. To investigate this finding further, in the present study participants navigated a virtual T maze and received feedback on each trial under two conditions. In a reward condition, the feedback indicated that they would either receive a monetary reward or not and in a punishment condition the feedback indicated that they would receive a small shock or not. We found that the feedback stimuli elicited a typical reward positivity in the reward condition and an apparently delayed reward positivity in the punishment condition. Importantly, this signal was more positive to the stimuli that predicted the omission of a possible punishment relative to stimuli that predicted a forthcoming punishment, which is inconsistent with the salience hypothesis. © 2016 Society for Psychophysiological Research.

  19. Accuracy of Robotic Radiosurgical Liver Treatment Throughout the Respiratory Cycle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winter, Jeff D.; Wong, Raimond; Swaminath, Anand

    Purpose: To quantify random uncertainties in robotic radiosurgical treatment of liver lesions with real-time respiratory motion management. Methods and Materials: We conducted a retrospective analysis of 27 liver cancer patients treated with robotic radiosurgery over 118 fractions. The robotic radiosurgical system uses orthogonal x-ray images to determine internal target position and correlates this position with an external surrogate to provide robotic corrections of linear accelerator positioning. Verification and update of this internal–external correlation model was achieved using periodic x-ray images collected throughout treatment. To quantify random uncertainties in targeting, we analyzed logged tracking information and isolated x-ray images collected immediately beforemore » beam delivery. For translational correlation errors, we quantified the difference between correlation model–estimated target position and actual position determined by periodic x-ray imaging. To quantify prediction errors, we computed the mean absolute difference between the predicted coordinates and actual modeled position calculated 115 milliseconds later. We estimated overall random uncertainty by quadratically summing correlation, prediction, and end-to-end targeting errors. We also investigated relationships between tracking errors and motion amplitude using linear regression. Results: The 95th percentile absolute correlation errors in each direction were 2.1 mm left–right, 1.8 mm anterior–posterior, 3.3 mm cranio–caudal, and 3.9 mm 3-dimensional radial, whereas 95th percentile absolute radial prediction errors were 0.5 mm. Overall 95th percentile random uncertainty was 4 mm in the radial direction. Prediction errors were strongly correlated with modeled target amplitude (r=0.53-0.66, P<.001), whereas only weak correlations existed for correlation errors. Conclusions: Study results demonstrate that model correlation errors are the primary random source of uncertainty in Cyberknife liver treatment and, unlike prediction errors, are not strongly correlated with target motion amplitude. Aggregate 3-dimensional radial position errors presented here suggest the target will be within 4 mm of the target volume for 95% of the beam delivery.« less

  20. Error analysis for relay type satellite-aided search and rescue systems

    NASA Technical Reports Server (NTRS)

    Marini, J. W.

    1977-01-01

    An analysis was made of the errors in the determination of the position of an emergency transmitter in a satellite aided search and rescue system. The satellite was assumed to be at a height of 820 km in a near circular near polar orbit. Short data spans of four minutes or less were used. The error sources considered were measurement noise, transmitter frequency drift, ionospheric effects and error in the assumed height of the transmitter. The errors were calculated for several different transmitter positions, data rates and data spans. The only transmitter frequency used was 406 MHz, but the results can be scaled to different frequencies. In a typical case, in which four Doppler measurements were taken over a span of two minutes, the position error was about 1.2 km.

  1. Experimental determination of the navigation error of the 4-D navigation, guidance, and control systems on the NASA B-737 airplane

    NASA Technical Reports Server (NTRS)

    Knox, C. E.

    1978-01-01

    Navigation error data from these flights are presented in a format utilizing three independent axes - horizontal, vertical, and time. The navigation position estimate error term and the autopilot flight technical error term are combined to form the total navigation error in each axis. This method of error presentation allows comparisons to be made between other 2-, 3-, or 4-D navigation systems and allows experimental or theoretical determination of the navigation error terms. Position estimate error data are presented with the navigation system position estimate based on dual DME radio updates that are smoothed with inertial velocities, dual DME radio updates that are smoothed with true airspeed and magnetic heading, and inertial velocity updates only. The normal mode of navigation with dual DME updates that are smoothed with inertial velocities resulted in a mean error of 390 m with a standard deviation of 150 m in the horizontal axis; a mean error of 1.5 m low with a standard deviation of less than 11 m in the vertical axis; and a mean error as low as 252 m with a standard deviation of 123 m in the time axis.

  2. Differences among Job Positions Related to Communication Errors at Construction Sites

    NASA Astrophysics Data System (ADS)

    Takahashi, Akiko; Ishida, Toshiro

    In a previous study, we classified the communicatio n errors at construction sites as faulty intention and message pattern, inadequate channel pattern, and faulty comprehension pattern. This study seeks to evaluate the degree of risk of communication errors and to investigate differences among people in various job positions in perception of communication error risk . Questionnaires based on the previous study were a dministered to construction workers (n=811; 149 adminis trators, 208 foremen and 454 workers). Administrators evaluated all patterns of communication error risk equally. However, foremen and workers evaluated communication error risk differently in each pattern. The common contributing factors to all patterns wer e inadequate arrangements before work and inadequate confirmation. Some factors were common among patterns but other factors were particular to a specific pattern. To help prevent future accidents at construction sites, administrators should understand how people in various job positions perceive communication errors and propose human factors measures to prevent such errors.

  3. Real-time auto-adaptive margin generation for MLC-tracked radiotherapy

    NASA Astrophysics Data System (ADS)

    Glitzner, M.; Fast, M. F.; de Senneville, B. Denis; Nill, S.; Oelfke, U.; Lagendijk, J. J. W.; Raaymakers, B. W.; Crijns, S. P. M.

    2017-01-01

    In radiotherapy, abdominal and thoracic sites are candidates for performing motion tracking. With real-time control it is possible to adjust the multileaf collimator (MLC) position to the target position. However, positions are not perfectly matched and position errors arise from system delays and complicated response of the electromechanic MLC system. Although, it is possible to compensate parts of these errors by using predictors, residual errors remain and need to be compensated to retain target coverage. This work presents a method to statistically describe tracking errors and to automatically derive a patient-specific, per-segment margin to compensate the arising underdosage on-line, i.e. during plan delivery. The statistics of the geometric error between intended and actual machine position are derived using kernel density estimators. Subsequently a margin is calculated on-line according to a selected coverage parameter, which determines the amount of accepted underdosage. The margin is then applied onto the actual segment to accommodate the positioning errors in the enlarged segment. The proof-of-concept was tested in an on-line tracking experiment and showed the ability to recover underdosages for two test cases, increasing {{V}90 %} in the underdosed area about 47 % and 41 % , respectively. The used dose model was able to predict the loss of dose due to tracking errors and could be used to infer the necessary margins. The implementation had a running time of 23 ms which is compatible with real-time requirements of MLC tracking systems. The auto-adaptivity to machine and patient characteristics makes the technique a generic yet intuitive candidate to avoid underdosages due to MLC tracking errors.

  4. Contingent negative variation (CNV) associated with sensorimotor timing error correction.

    PubMed

    Jang, Joonyong; Jones, Myles; Milne, Elizabeth; Wilson, Daniel; Lee, Kwang-Hyuk

    2016-02-15

    Detection and subsequent correction of sensorimotor timing errors are fundamental to adaptive behavior. Using scalp-recorded event-related potentials (ERPs), we sought to find ERP components that are predictive of error correction performance during rhythmic movements. Healthy right-handed participants were asked to synchronize their finger taps to a regular tone sequence (every 600 ms), while EEG data were continuously recorded. Data from 15 participants were analyzed. Occasional irregularities were built into stimulus presentation timing: 90 ms before (advances: negative shift) or after (delays: positive shift) the expected time point. A tapping condition alternated with a listening condition in which identical stimulus sequence was presented but participants did not tap. Behavioral error correction was observed immediately following a shift, with a degree of over-correction with positive shifts. Our stimulus-locked ERP data analysis revealed, 1) increased auditory N1 amplitude for the positive shift condition and decreased auditory N1 modulation for the negative shift condition; and 2) a second enhanced negativity (N2) in the tapping positive condition, compared with the tapping negative condition. In response-locked epochs, we observed a CNV (contingent negative variation)-like negativity with earlier latency in the tapping negative condition compared with the tapping positive condition. This CNV-like negativity peaked at around the onset of subsequent tapping, with the earlier the peak, the better the error correction performance with the negative shifts while the later the peak, the better the error correction performance with the positive shifts. This study showed that the CNV-like negativity was associated with the error correction performance during our sensorimotor synchronization study. Auditory N1 and N2 were differentially involved in negative vs. positive error correction. However, we did not find evidence for their involvement in behavioral error correction. Overall, our study provides the basis from which further research on the role of the CNV in perceptual and motor timing can be developed. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Spatio-Temporal Tracking and Phylodynamics of an Urban Dengue 3 Outbreak in São Paulo, Brazil

    PubMed Central

    Mondini, Adriano; Bronzoni, Roberta Vieira de Moraes; Nunes, Silvia Helena Pereira; Chiaravalloti Neto, Francisco; Massad, Eduardo; Alonso, Wladimir J.; Lázzaro, Eduardo S. M.; Ferraz, Amena Alcântara; de Andrade Zanotto, Paolo Marinho; Nogueira, Maurício Lacerda

    2009-01-01

    The dengue virus has a single-stranded positive-sense RNA genome of ∼10.700 nucleotides with a single open reading frame that encodes three structural (C, prM, and E) and seven nonstructural (NS1, NS2A, NS2B, NS3, NS4A, NS4B, and NS5) proteins. It possesses four antigenically distinct serotypes (DENV 1–4). Many phylogenetic studies address particularities of the different serotypes using convenience samples that are not conducive to a spatio-temporal analysis in a single urban setting. We describe the pattern of spread of distinct lineages of DENV-3 circulating in São José do Rio Preto, Brazil, during 2006. Blood samples from patients presenting dengue-like symptoms were collected for DENV testing. We performed M-N-PCR using primers based on NS5 for virus detection and identification. The fragments were purified from PCR mixtures and sequenced. The positive dengue cases were geo-coded. To type the sequenced samples, 52 reference sequences were aligned. The dataset generated was used for iterative phylogenetic reconstruction with the maximum likelihood criterion. The best demographic model, the rate of growth, rate of evolutionary change, and Time to Most Recent Common Ancestor (TMRCA) were estimated. The basic reproductive rate during the epidemics was estimated. We obtained sequences from 82 patients among 174 blood samples. We were able to geo-code 46 sequences. The alignment generated a 399-nucleotide-long dataset with 134 taxa. The phylogenetic analysis indicated that all samples were of DENV-3 and related to strains circulating on the isle of Martinique in 2000–2001. Sixty DENV-3 from São José do Rio Preto formed a monophyletic group (lineage 1), closely related to the remaining 22 isolates (lineage 2). We assumed that these lineages appeared before 2006 in different occasions. By transforming the inferred exponential growth rates into the basic reproductive rate, we obtained values for lineage 1 of R0 = 1.53 and values for lineage 2 of R0 = 1.13. Under the exponential model, TMRCA of lineage 1 dated 1 year and lineage 2 dated 3.4 years before the last sampling. The possibility of inferring the spatio-temporal dynamics from genetic data has been generally little explored, and it may shed light on DENV circulation. The use of both geographic and temporally structured phylogenetic data provided a detailed view on the spread of at least two dengue viral strains in a populated urban area. PMID:19478848

  6. Finkelstein's test: a descriptive error that can produce a false positive.

    PubMed

    Elliott, B G

    1992-08-01

    Over the last three decades an error in performing Finkelstein's test has crept into the English literature in both text books and journals. This error can produce a false-positive, and if relied upon, a wrong diagnosis can be made, leading to inappropriate surgery.

  7. Coherent detection of position errors in inter-satellite laser communications

    NASA Astrophysics Data System (ADS)

    Xu, Nan; Liu, Liren; Liu, De'an; Sun, Jianfeng; Luan, Zhu

    2007-09-01

    Due to the improved receiver sensitivity and wavelength selectivity, coherent detection became an attractive alternative to direct detection in inter-satellite laser communications. A novel method to coherent detection of position errors information is proposed. Coherent communication system generally consists of receive telescope, local oscillator, optical hybrid, photoelectric detector and optical phase lock loop (OPLL). Based on the system composing, this method adds CCD and computer as position error detector. CCD captures interference pattern while detection of transmission data from the transmitter laser. After processed and analyzed by computer, target position information is obtained from characteristic parameter of the interference pattern. The position errors as the control signal of PAT subsystem drive the receiver telescope to keep tracking to the target. Theoretical deviation and analysis is presented. The application extends to coherent laser rang finder, in which object distance and position information can be obtained simultaneously.

  8. Direct evidence for a position input to the smooth pursuit system.

    PubMed

    Blohm, Gunnar; Missal, Marcus; Lefèvre, Philippe

    2005-07-01

    When objects move in our environment, the orientation of the visual axis in space requires the coordination of two types of eye movements: saccades and smooth pursuit. The principal input to the saccadic system is position error, whereas it is velocity error for the smooth pursuit system. Recently, it has been shown that catch-up saccades to moving targets are triggered and programmed by using velocity error in addition to position error. Here, we show that, when a visual target is flashed during ongoing smooth pursuit, it evokes a smooth eye movement toward the flash. The velocity of this evoked smooth movement is proportional to the position error of the flash; it is neither influenced by the velocity of the ongoing smooth pursuit eye movement nor by the occurrence of a saccade, but the effect is absent if the flash is ignored by the subject. Furthermore, the response started around 85 ms after the flash presentation and decayed with an average time constant of 276 ms. Thus this is the first direct evidence of a position input to the smooth pursuit system. This study shows further evidence for a coupling between saccadic and smooth pursuit systems. It also suggests that there is an interaction between position and velocity error signals in the control of more complex movements.

  9. The Importance of Semi-Major Axis Knowledge in the Determination of Near-Circular Orbits

    NASA Technical Reports Server (NTRS)

    Carpenter, J. Russell; Schiesser, Emil R.

    1998-01-01

    Modem orbit determination has mostly been accomplished using Cartesian coordinates. This usage has carried over in recent years to the use of GPS for satellite orbit determination. The unprecedented positioning accuracy of GPS has tended to focus attention more on the system's capability to locate the spacecraft's location at a particular epoch than on its accuracy in determination of the orbit, per se. As is well-known, the latter depends on a coordinated knowledge of position, velocity, and the correlation between their errors. Failure to determine a properly coordinated position/velocity state vector at a given epoch can lead to an epoch state that does not propagate well, and/or may not be usable for the execution of orbit adjustment maneuvers. For the quite common case of near-circular orbits, the degree to which position and velocity estimates are properly coordinated is largely captured by the error in semi-major axis (SMA) they jointly produce. Figure 1 depicts the relationships among radius error, speed error, and their correlation which exist for a typical low altitude Earth orbit. Two familiar consequences are the relationship Figure 1 shows are the following: (1) downrange position error grows at the per orbit rate of 3(pi) times the SMA error; (2) a velocity change imparted to the orbit will have an error of (pi) divided by the orbit period times the SMA error. A less familiar consequence occurs in the problem of initializing the covariance matrix for a sequential orbit determination filter. An initial covariance consistent with orbital dynamics should be used if the covariance is to propagate well. Properly accounting for the SMA error of the initial state in the construction of the initial covariance accomplishes half of this objective, by specifying the partition of the covariance corresponding to down-track position and radial velocity errors. The remainder of the in-plane covariance partition may be specified in terms of the flight path angle error of the initial state. Figure 2 illustrates the effect of properly and not properly initializing a covariance. This figure was produced by propagating the covariance shown on the plot, without process noise, in a circular low Earth orbit whose period is 5828.5 seconds. The upper subplot, in which the proper relationships among position, velocity, and their correlation has been used, shows overall error growth, in terms of the standard deviations of the inertial position coordinates, of about half of the lower subplot, whose initial covariance was based on other considerations.

  10. Enhanced Pedestrian Navigation Based on Course Angle Error Estimation Using Cascaded Kalman Filters

    PubMed Central

    Park, Chan Gook

    2018-01-01

    An enhanced pedestrian dead reckoning (PDR) based navigation algorithm, which uses two cascaded Kalman filters (TCKF) for the estimation of course angle and navigation errors, is proposed. The proposed algorithm uses a foot-mounted inertial measurement unit (IMU), waist-mounted magnetic sensors, and a zero velocity update (ZUPT) based inertial navigation technique with TCKF. The first stage filter estimates the course angle error of a human, which is closely related to the heading error of the IMU. In order to obtain the course measurements, the filter uses magnetic sensors and a position-trace based course angle. For preventing magnetic disturbance from contaminating the estimation, the magnetic sensors are attached to the waistband. Because the course angle error is mainly due to the heading error of the IMU, and the characteristic error of the heading angle is highly dependent on that of the course angle, the estimated course angle error is used as a measurement for estimating the heading error in the second stage filter. At the second stage, an inertial navigation system-extended Kalman filter-ZUPT (INS-EKF-ZUPT) method is adopted. As the heading error is estimated directly by using course-angle error measurements, the estimation accuracy for the heading and yaw gyro bias can be enhanced, compared with the ZUPT-only case, which eventually enhances the position accuracy more efficiently. The performance enhancements are verified via experiments, and the way-point position error for the proposed method is compared with those for the ZUPT-only case and with other cases that use ZUPT and various types of magnetic heading measurements. The results show that the position errors are reduced by a maximum of 90% compared with the conventional ZUPT based PDR algorithms. PMID:29690539

  11. SU-E-T-144: Effective Analysis of VMAT QA Generated Trajectory Log Files for Medical Accelerator Predictive Maintenance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Able, CM; Baydush, AH; Nguyen, C

    Purpose: To determine the effectiveness of SPC analysis for a model predictive maintenance process that uses accelerator generated parameter and performance data contained in trajectory log files. Methods: Each trajectory file is decoded and a total of 131 axes positions are recorded (collimator jaw position, gantry angle, each MLC, etc.). This raw data is processed and either axis positions are extracted at critical points during the delivery or positional change over time is used to determine axis velocity. The focus of our analysis is the accuracy, reproducibility and fidelity of each axis. A reference positional trace of the gantry andmore » each MLC is used as a motion baseline for cross correlation (CC) analysis. A total of 494 parameters (482 MLC related) were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and parameter/system specifications. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: TG-142 and published analysis of VMAT delivery accuracy. Results: All errors introduced were detected. Synthetic positional errors of 2mm for collimator jaw and MLC carriage exceeded the chart limits. Gantry speed and each MLC speed are analyzed at two different points in the delivery. Simulated Gantry speed error (0.2 deg/sec) and MLC speed error (0.1 cm/sec) exceeded the speed chart limits. Gantry position error of 0.2 deg was detected by the CC maximum value charts. The MLC position error of 0.1 cm was detected by the CC maximum value location charts for every MLC. Conclusion: SPC I/MR evaluation of trajectory log file parameters may be effective in providing an early warning of performance degradation or component failure for medical accelerator systems.« less

  12. Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoiber, Eva Maria, E-mail: eva.stoiber@med.uni-heidelberg.de; Department of Medical Physics, German Cancer Research Center, Heidelberg; Giske, Kristina

    Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived frommore » a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.« less

  13. SU-F-E-18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self-Learning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Court, L; Wang, H; Aten, D

    Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de-calibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral andmore » vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non-English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch errors within the criteria suggested by AAPM TG142 for linacs used for IMRT.« less

  14. Position sense at the human elbow joint measured by arm matching or pointing.

    PubMed

    Tsay, Anthony; Allen, Trevor J; Proske, Uwe

    2016-10-01

    Position sense at the human elbow joint has traditionally been measured in blindfolded subjects using a forearm matching task. Here we compare position errors in a matching task with errors generated when the subject uses a pointer to indicate the position of a hidden arm. Evidence from muscle vibration during forearm matching supports a role for muscle spindles in position sense. We have recently shown using vibration, as well as muscle conditioning, which takes advantage of muscle's thixotropic property, that position errors generated in a forearm pointing task were not consistent with a role by muscle spindles. In the present study we have used a form of muscle conditioning, where elbow muscles are co-contracted at the test angle, to further explore differences in position sense measured by matching and pointing. For fourteen subjects, in a matching task where the reference arm had elbow flexor and extensor muscles contracted at the test angle and the indicator arm had its flexors conditioned at 90°, matching errors lay in the direction of flexion by 6.2°. After the same conditioning of the reference arm and extension conditioning of the indicator at 0°, matching errors lay in the direction of extension (5.7°). These errors were consistent with predictions based on a role by muscle spindles in determining forearm matching outcomes. In the pointing task subjects moved a pointer to align it with the perceived position of the hidden arm. After conditioning of the reference arm as before, pointing errors all lay in a more extended direction than the actual position of the arm by 2.9°-7.3°, a distribution not consistent with a role by muscle spindles. We propose that in pointing muscle spindles do not play the major role in signalling limb position that they do in matching, but that other sources of sensory input should be given consideration, including afferents from skin and joint.

  15. What to Consider When Preparing a Model Core Curriculum for GIS Ethics: Objectives, Methods, and a Sketch of Content

    ERIC Educational Resources Information Center

    Davis, Michael

    2014-01-01

    The purpose of this article is to provide a summary of what is known about teaching ethics in engineering, science, and related disciplines. Such a summary should provide a useful starting point for preparation of a detailed curriculum for teaching the ethics of geo-coded information systems broadly understood ("GIS ethics" for short).…

  16. The association of drinking water treatment and distribution network disturbances with Health Call Centre contacts for gastrointestinal illness symptoms.

    PubMed

    Malm, Annika; Axelsson, Gösta; Barregard, Lars; Ljungqvist, Jakob; Forsberg, Bertil; Bergstedt, Olof; Pettersson, Thomas J R

    2013-09-01

    There are relatively few studies on the association between disturbances in drinking water services and symptoms of gastrointestinal (GI) illness. Health Call Centres data concerning GI illness may be a useful source of information. This study investigates if there is an increased frequency of contacts with the Health Call Centre (HCC) concerning gastrointestinal symptoms at times when there is a risk of impaired water quality due to disturbances at water works or the distribution network. The study was conducted in Gothenburg, a Swedish city with 0.5 million inhabitants with a surface water source of drinking water and two water works. All HCC contacts due to GI symptoms (diarrhoea, vomiting or abdominal pain) were recorded for a three-year period, including also sex, age, and geocoded location of residence. The number of contacts with the HCC in the affected geographical areas were recorded during eight periods of disturbances in the water works (e.g. short stops of chlorine dosing), six periods of large disturbances in the distribution network (e.g. pumping station failure or pipe breaks with major consequences), and 818 pipe break and leak repairs over a three-year period. For each period of disturbance the observed number of calls was compared with the number of calls during a control period without disturbances in the same geographical area. In total about 55, 000 calls to the HCC due to GI symptoms were recorded over the three-year period, 35 per 1000 inhabitants and year, but much higher (>200) for children <3 yrs of age. There was no statistically significant increase in calls due to GI illness during or after disturbances at the water works or in the distribution network. Our results indicate that GI symptoms due to disturbances in water works or the distribution network are rare. The number of serious failures was, however limited, and further studies are needed to be able to assess the risk of GI illness in such cases. The technique of using geocoded HCC data together with geocoded records of disturbances in the drinking water network was feasible. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Risk factors for differential outcome following directly observed treatment (DOT) of slum and non-slum tuberculosis patients: a retrospective cohort study.

    PubMed

    Snyder, Robert E; Marlow, Mariel A; Phuphanich, Melissa E; Riley, Lee W; Maciel, Ethel Leonor Noia

    2016-09-20

    Brazil's National Tuberculosis Control Program seeks to improve tuberculosis (TB) treatment in vulnerable populations. Slum residents are more vulnerable to TB due to a variety of factors, including their overcrowded living conditions, substandard infrastructure, and limited access to healthcare compared to their non-slum dwelling counterparts. Directly observed treatment (DOT) has been suggested to improve TB treatment outcomes among vulnerable populations, but the program's differential effectiveness among urban slum and non-slum residents is not known. We retrospectively compared the impact of DOT on TB treatment outcome in residents of slum and non-slum census tracts in Rio de Janeiro reported to the Brazilian Notifiable Disease Database in 2010. Patient residential addresses were geocoded to census tracts from the 2010 Brazilian Census, which were identified as slum (aglomerados subnormais -AGSN) and non-slum (non-AGSN) by the Census Bureau. Homeless and incarcerated cases as well as those geocoded outside the city's limits were excluded from analysis. In 2010, 6,601 TB cases were geocoded within Rio de Janeiro; 1,874 (27.4 %) were residents of AGSN, and 4,794 (72.6 %) did not reside in an AGSN area. DOT coverage among AGSN cases was 35.2 % (n = 638), while the coverage in non-AGSN cases was 26.2 % (n = 1,234). Clinical characteristics, treatment, follow-up, cure, death and abandonment were similar in both AGSN and non-AGSN TB patients. After adjusting for covariates, AGSN TB cases on DOT had 1.67 (95 % CI: 1.17, 2.4) times the risk of cure, 0.61 (95 % CI: 0.41, 0.90) times the risk of abandonment, and 0.1 (95 % CI: 0.01, 0.77) times the risk of death from TB compared to non-AGSN TB cases not on DOT. While DOT coverage was low among TB cases in both AGSN and non-AGSN communities, it had a greater impact on TB cure rate in AGSN than in non-AGSN populations in the city of Rio de Janeiro.

  18. Differential-Drive Mobile Robot Control Design based-on Linear Feedback Control Law

    NASA Astrophysics Data System (ADS)

    Nurmaini, Siti; Dewi, Kemala; Tutuko, Bambang

    2017-04-01

    This paper deals with the problem of how to control differential driven mobile robot with simple control law. When mobile robot moves from one position to another to achieve a position destination, it always produce some errors. Therefore, a mobile robot requires a certain control law to drive the robot’s movement to the position destination with a smallest possible error. In this paper, in order to reduce position error, a linear feedback control is proposed with pole placement approach to regulate the polynoms desired. The presented work leads to an improved understanding of differential-drive mobile robot (DDMR)-based kinematics equation, which will assist to design of suitable controllers for DDMR movement. The result show by using the linier feedback control method with pole placement approach the position error is reduced and fast convergence is achieved.

  19. Analysis of Sources of Large Positioning Errors in Deterministic Fingerprinting

    PubMed Central

    2017-01-01

    Wi-Fi fingerprinting is widely used for indoor positioning and indoor navigation due to the ubiquity of wireless networks, high proliferation of Wi-Fi-enabled mobile devices, and its reasonable positioning accuracy. The assumption is that the position can be estimated based on the received signal strength intensity from multiple wireless access points at a given point. The positioning accuracy, within a few meters, enables the use of Wi-Fi fingerprinting in many different applications. However, it has been detected that the positioning error might be very large in a few cases, which might prevent its use in applications with high accuracy positioning requirements. Hybrid methods are the new trend in indoor positioning since they benefit from multiple diverse technologies (Wi-Fi, Bluetooth, and Inertial Sensors, among many others) and, therefore, they can provide a more robust positioning accuracy. In order to have an optimal combination of technologies, it is crucial to identify when large errors occur and prevent the use of extremely bad positioning estimations in hybrid algorithms. This paper investigates why large positioning errors occur in Wi-Fi fingerprinting and how to detect them by using the received signal strength intensities. PMID:29186921

  20. Analytic aerotriangulation utilizing Skylab earth terrain camera (S-190B) photography. [from Charlotte, North Carolina to Rappahannock River in Virginia

    NASA Technical Reports Server (NTRS)

    Keller, M. (Principal Investigator)

    1975-01-01

    The author has identified the following significant results. Inherent errors in using nonmetric Skylab photography and office-identified photo control made it necessary to perform numerous block adjustment solutions involving different combinations of control and weights. The final block adjustment was executed holding to 14 of the office-identified photo control points. Solution accuracy was evaluated by comparing the analytically computed ground positions of the withheld photo control points with their known ground positions and also by determining the standard errors of these points from variance values. A horizontal position RMS error of 15 meters was attained. The maximum observed error in position at a control point was 25 meters.

  1. The usefulness of GPS bicycle tracking data for evaluating the impact of infrastructure change on cycling behaviour.

    PubMed

    Heesch, Kristiann C; Langdon, Michael

    2016-02-01

    Issue addressed A key strategy to increase active travel is the construction of bicycle infrastructure. Tools to evaluate this strategy are limited. This study assessed the usefulness of a smartphone GPS tracking system for evaluating the impact of this strategy on cycling behaviour. Methods Cycling usage data were collected from Queenslanders who used a GPS tracking app on their smartphone from 2013-2014. 'Heat' and volume maps of the data were reviewed, and GPS bicycle counts were compared with surveillance data and bicycle counts from automatic traffic-monitoring devices. Results Heat maps broadly indicated that changes in cycling occurred near infrastructure improvements. Volume maps provided changes in counts of cyclists due to these improvements although errors were noted in geographic information system (GIS) geo-coding of some GPS data. Large variations were evident in the number of cyclists using the app in different locations. These variations limited the usefulness of GPS data for assessing differences in cycling across locations. Conclusion Smartphone GPS data are useful in evaluating the impact of improved bicycle infrastructure in one location. Using GPS data to evaluate differential changes in cycling across multiple locations is problematic when there is insufficient traffic-monitoring devices available to triangulate GPS data with bicycle traffic count data. So what? The use of smartphone GPS data with other data sources is recommended for assessing how infrastructure improvements influence cycling behaviour.

  2. Field validation of secondary data sources for enumerating retail tobacco outlets in a state without tobacco outlet licensing.

    PubMed

    D'Angelo, Heather; Fleischhacker, Sheila; Rose, Shyanika W; Ribisl, Kurt M

    2014-07-01

    Identifying tobacco retail outlets for U.S. FDA compliance checks or calculating tobacco outlet density is difficult in the 13 States without tobacco retail licensing or where licensing lists are unavailable for research. This study uses primary data collection to identify tobacco outlets in three counties in a non-licensing state and validate two commercial secondary data sources. We calculated sensitivity and positive predictive values (PPV) to examine the evidence of validity for two secondary data sources, and conducted a geospatial analysis to determine correct allocation to census tract. ReferenceUSA had almost perfect sensitivity (0.82) while Dun & Bradstreet (D&B) had substantial sensitivity (0.69) for identifying tobacco outlets; combined, sensitivity improved to 0.89. D&B identified fewer "false positives" with a PPV of 0.82 compared to 0.71 for ReferenceUSA. More than 90% of the outlets identified by ReferenceUSA were geocoded to the correct census tract. Combining two commercial data sources resulted in enumeration of nearly 90% of tobacco outlets in a three county area. Commercial databases appear to provide a reasonably accurate way to identify tobacco outlets for enforcement operations and density estimation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Non-linear dynamic compensation system

    NASA Technical Reports Server (NTRS)

    Lin, Yu-Hwan (Inventor); Lurie, Boris J. (Inventor)

    1992-01-01

    A non-linear dynamic compensation subsystem is added in the feedback loop of a high precision optical mirror positioning control system to smoothly alter the control system response bandwidth from a relatively wide response bandwidth optimized for speed of control system response to a bandwidth sufficiently narrow to reduce position errors resulting from the quantization noise inherent in the inductosyn used to measure mirror position. The non-linear dynamic compensation system includes a limiter for limiting the error signal within preselected limits, a compensator for modifying the limiter output to achieve the reduced bandwidth response, and an adder for combining the modified error signal with the difference between the limited and unlimited error signals. The adder output is applied to control system motor so that the system response is optimized for accuracy when the error signal is within the preselected limits, optimized for speed of response when the error signal is substantially beyond the preselected limits and smoothly varied therebetween as the error signal approaches the preselected limits.

  4. Analysis of DGPS/INS and MLS/INS final approach navigation errors and control performance data

    NASA Technical Reports Server (NTRS)

    Hueschen, Richard M.; Spitzer, Cary R.

    1992-01-01

    Flight tests were conducted jointly by NASA Langley Research Center and Honeywell, Inc., on a B-737 research aircraft to record a data base for evaluating the performance of a differential DGPS/inertial navigation system (INS) which used GPS Course/Acquisition code receivers. Estimates from the DGPS/INS and a Microwave Landing System (MLS)/INS, and various aircraft parameter data were recorded in real time aboard the aircraft while flying along the final approach path to landing. This paper presents the mean and standard deviation of the DGPS/INS and MLS/INS navigation position errors computed relative to the laser tracker system and of the difference between the DGPS/INS and MLS/INS velocity estimates. RMS errors are presented for DGPS/INS and MLS/INS guidance errors (localizer and glideslope). The mean navigation position errors and standard deviation of the x position coordinate of the DGPS/INS and MLS/INS systems were found to be of similar magnitude while the standard deviation of the y and z position coordinate errors were significantly larger for DGPS/INS compared to MLS/INS.

  5. Quality assurance of dynamic parameters in volumetric modulated arc therapy

    PubMed Central

    Manikandan, A; Sarkar, B; Holla, R; Vivek, T R; Sujatha, N

    2012-01-01

    Objectives The purpose of this study was to demonstrate quality assurance checks for accuracy of gantry speed and position, dose rate and multileaf collimator (MLC) speed and position for a volumetric modulated arc treatment (VMAT) modality (Synergy® S; Elekta, Stockholm, Sweden), and to check that all the necessary variables and parameters were synchronous. Methods Three tests (for gantry position–dose delivery synchronisation, gantry speed–dose delivery synchronisation and MLC leaf speed and positions) were performed. Results The average error in gantry position was 0.5° and the average difference was 3 MU for a linear and a parabolic relationship between gantry position and delivered dose. In the third part of this test (sawtooth variation), the maximum difference was 9.3 MU, with a gantry position difference of 1.2°. In the sweeping field method test, a linear relationship was observed between recorded doses and distance from the central axis, as expected. In the open field method, errors were encountered at the beginning and at the end of the delivery arc, termed the “beginning” and “end” errors. For MLC position verification, the maximum error was −2.46 mm and the mean error was 0.0153 ±0.4668 mm, and 3.4% of leaves analysed showed errors of >±1 mm. Conclusion This experiment demonstrates that the variables and parameters of the Synergy® S are synchronous and that the system is suitable for delivering VMAT using a dynamic MLC. PMID:22745206

  6. Use of Positive Blood Cultures for Direct Identification and Susceptibility Testing with the Vitek 2 System

    PubMed Central

    de Cueto, Marina; Ceballos, Esther; Martinez-Martinez, Luis; Perea, Evelio J.; Pascual, Alvaro

    2004-01-01

    In order to further decrease the time lapse between initial inoculation of blood culture media and the reporting of results of identification and antimicrobial susceptibility tests for microorganisms causing bacteremia, we performed a prospective study in which specially processed fluid from positive blood culture bottles from Bactec 9240 (Becton Dickinson, Cockeysville, Md.) containing aerobic media were directly inoculated into Vitek 2 system cards (bio-Mérieux, France). Organism identification and susceptibility results were compared with those obtained from cards inoculated with a standardized bacterial suspension obtained following subculture to agar; 100 consecutive positive monomicrobic blood cultures, consisting of 50 gram-negative rods and 50 gram-positive cocci, were included in the study. For gram-negative organisms, 31 of the 50 (62%) showed complete agreement with the standard method for species identification, while none of the 50 gram-positive cocci were correctly identified by the direct method. For gram-negative rods, there were 50% categorical agreements between the direct and standard methods for all drugs tested. The very major error rate was 2.4%, and the major error rate was 0.6%. The overall error rate for gram-negatives was 6.6%. Complete agreement in clinical categories of all antimicrobial agents evaluated was obtained for 19 of 50 (38%) gram-positive cocci evaluated; the overall error rate was 8.4%, with 2.8% minor errors, 2.4% major errors, and 3.2% very major errors. These findings suggest that the Vitek 2 cards inoculated directly from positive Bactec 9240 bottles do not provide acceptable bacterial identification or susceptibility testing in comparison with corresponding cards tested by a standard method. PMID:15297523

  7. Condom Use Errors and Problems: A Comparative Study of HIV-Positive Versus HIV-Negative Young Black MSM

    PubMed Central

    Crosby, Richard; Mena, Leandro; Yarber, William L.; Graham, Cynthia A.; Sanders, Stephanie A.; Milhausen, Robin R.

    2015-01-01

    Objective To describe self-reported frequencies of selected condom use errors and problems among young (ages 15–29) Black MSM (YBMSM) and to compare the observed prevalence of these errors/problems by HIV serostatus. Methods Between September 2012 October 2014, electronic interview data were collected from 369 YBMSM attending a federally supported STI clinic located in the southern U.S. Seventeen condom use errors and problems were assessed. Chi-square tests were used to detect significant differences in the prevalence of these 17 errors and problems between HIV-negative and HIV-positive men. Results The recall period was the past 90 days. The overall mean number of errors/problems was 2.98 (sd=2.29). The mean for HIV-negative men was 2.91 (sd=2.15) and the mean for HIV-positive men was 3.18 (sd=2.57). These means were not significantly different (t=1.02, df=367, P=.31). Only two significant differences were observed between HIV-negative and HIV-positive men. Breakage (P = .002) and slippage (P = .005) were about twice as likely among HIV-positive men. Breakage occurred for nearly 30% of the HIV-positive men compared to about 15% among HIV-negative men. Slippage occurred for about 16% of the HIV-positive men compared to about 9% among HIV-negative men. Conclusion A need exists to help YBMSM acquire the skills needed to avert breakage and slippage issues that could lead to HIV transmission. Beyond these two exceptions, condom use errors and problems were ubiquitous in this population regardless of HIV serostatus. Clinic-based intervention is warranted for these young men, including education about correct condom use and provision of free condoms and long-lasting lubricants. PMID:26462188

  8. Design of a Pneumatic Tool for Manual Drilling Operations in Confined Spaces

    NASA Astrophysics Data System (ADS)

    Janicki, Benjamin

    This master's thesis describes the design process and testing results for a pneumatically actuated, manually-operated tool for confined space drilling operations. The purpose of this device is to back-drill pilot holes inside a commercial airplane wing. It is lightweight, and a "locator pin" enables the operator to align the drill over a pilot hole. A suction pad stabilizes the system, and an air motor and flexible drive shaft power the drill. Two testing procedures were performed to determine the practicality of this prototype. The first was the "offset drill test", which qualified the exit hole position error due to an initial position error relative to the original pilot hole. The results displayed a linear relationship, and it was determined that position errors of less than .060" would prevent the need for rework, with errors of up to .030" considered acceptable. For the second test, a series of holes were drilled with the pneumatic tool and analyzed for position error, diameter range, and cycle time. The position errors and hole diameter range were within the allowed tolerances. The average cycle time was 45 seconds, 73 percent of which was for drilling the hole, and 27 percent of which was for positioning the device. Recommended improvements are discussed in the conclusion, and include a more durable flexible drive shaft, a damper for drill feed control, and a more stable locator pin.

  9. Effect of endorectal balloon positioning errors on target deformation and dosimetric quality during prostate SBRT

    NASA Astrophysics Data System (ADS)

    Jones, Bernard L.; Gan, Gregory; Kavanagh, Brian; Miften, Moyed

    2013-11-01

    An inflatable endorectal balloon (ERB) is often used during stereotactic body radiation therapy (SBRT) for treatment of prostate cancer in order to reduce both intrafraction motion of the target and risk of rectal toxicity. However, the ERB can exert significant force on the prostate, and this work assessed the impact of ERB position errors on deformation of the prostate and treatment dose metrics. Seventy-one cone-beam computed tomography (CBCT) image datasets of nine patients with clinical stage T1cN0M0 prostate cancer were studied. An ERB (Flexi-Cuff, EZ-EM, Westbury, NY) inflated with 60 cm3 of air was used during simulation and treatment, and daily kilovoltage (kV) CBCT imaging was performed to localize the prostate. The shape of the ERB in each CBCT was analyzed to determine errors in position, size, and shape. A deformable registration algorithm was used to track the dose received by (and deformation of) the prostate, and dosimetric values such as D95, PTV coverage, and Dice coefficient for the prostate were calculated. The average balloon position error was 0.5 cm in the inferior direction, with errors ranging from 2 cm inferiorly to 1 cm superiorly. The prostate was deformed primarily in the AP direction, and tilted primarily in the anterior-posterior/superior-inferior plane. A significant correlation was seen between errors in depth of ERB insertion (DOI) and mean voxel-wise deformation, prostate tilt, Dice coefficient, and planning-to-treatment prostate inter-surface distance (p < 0.001). Dosimetrically, DOI is negatively correlated with prostate D95 and PTV coverage (p < 0.001). For the model of ERB studied, error in ERB position can cause deformations in the prostate that negatively affect treatment, and this additional aspect of setup error should be considered when ERBs are used for prostate SBRT. Before treatment, the ERB position should be verified, and the ERB should be adjusted if the error is observed to exceed tolerable values.

  10. The role of visual spatial attention in adult developmental dyslexia.

    PubMed

    Collis, Nathan L; Kohnen, Saskia; Kinoshita, Sachiko

    2013-01-01

    The present study investigated the nature of visual spatial attention deficits in adults with developmental dyslexia, using a partial report task with five-letter, digit, and symbol strings. Participants responded by a manual key press to one of nine alternatives, which included other characters in the string, allowing an assessment of position errors as well as intrusion errors. The results showed that the dyslexic adults performed significantly worse than age-matched controls with letter and digit strings but not with symbol strings. Both groups produced W-shaped serial position functions with letter and digit strings. The dyslexics' deficits with letter string stimuli were limited to position errors, specifically at the string-interior positions 2 and 4. These errors correlated with letter transposition reading errors (e.g., reading slat as "salt"), but not with the Rapid Automatized Naming (RAN) task. Overall, these results suggest that the dyslexic adults have a visual spatial attention deficit; however, the deficit does not reflect a reduced span in visual-spatial attention, but a deficit in processing a string of letters in parallel, probably due to difficulty in the coding of letter position.

  11. Linear motor drive system for continuous-path closed-loop position control of an object

    DOEpatents

    Barkman, William E.

    1980-01-01

    A precision numerical controlled servo-positioning system is provided for continuous closed-loop position control of a machine slide or platform driven by a linear-induction motor. The system utilizes filtered velocity feedback to provide system stability required to operate with a system gain of 100 inches/minute/0.001 inch of following error. The filtered velocity feedback signal is derived from the position output signals of a laser interferometer utilized to monitor the movement of the slide. Air-bearing slides mounted to a stable support are utilized to minimize friction and small irregularities in the slideway which would tend to introduce positioning errors. A microprocessor is programmed to read command and feedback information and converts this information into the system following error signal. This error signal is summed with the negative filtered velocity feedback signal at the input of a servo amplifier whose output serves as the drive power signal to the linear motor position control coil.

  12. Aging and the intrusion superiority effect in visuo-spatial working memory.

    PubMed

    Cornoldi, Cesare; Bassani, Chiara; Berto, Rita; Mammarella, Nicola

    2007-01-01

    This study investigated the active component of visuo-spatial working memory (VSWM) in younger and older adults testing the hypotheses that elderly individuals have a poorer performance than younger ones and that errors in active VSWM tasks depend, at least partially, on difficulties in avoiding intrusions (i.e., avoiding already activated information). In two experiments, participants were presented with sequences of matrices on which three positions were pointed out sequentially: their task was to process all the positions but indicate only the final position of each sequence. Results showed a poorer performance in the elderly compared to the younger group and a higher number of intrusion (errors due to activated but irrelevant positions) rather than invention (errors consisting of pointing out a position never indicated by the experiementer) errors. The number of errors increased when a concurrent task was introduced (Experiment 1) and it was affected by different patterns of matrices (Experiment 2). In general, results show that elderly people have an impaired VSWM and produce a large number of errors due to inhibition failures. However, both the younger and the older adults' visuo-spatial working memory was affected by the presence of activated irrelevant information, the reduction of the available resources, and task constraints.

  13. Automatic learning rate adjustment for self-supervising autonomous robot control

    NASA Technical Reports Server (NTRS)

    Arras, Michael K.; Protzel, Peter W.; Palumbo, Daniel L.

    1992-01-01

    Described is an application in which an Artificial Neural Network (ANN) controls the positioning of a robot arm with five degrees of freedom by using visual feedback provided by two cameras. This application and the specific ANN model, local liner maps, are based on the work of Ritter, Martinetz, and Schulten. We extended their approach by generating a filtered, average positioning error from the continuous camera feedback and by coupling the learning rate to this error. When the network learns to position the arm, the positioning error decreases and so does the learning rate until the system stabilizes at a minimum error and learning rate. This abolishes the need for a predetermined cooling schedule. The automatic cooling procedure results in a closed loop control with no distinction between a learning phase and a production phase. If the positioning error suddenly starts to increase due to an internal failure such as a broken joint, or an environmental change such as a camera moving, the learning rate increases accordingly. Thus, learning is automatically activated and the network adapts to the new condition after which the error decreases again and learning is 'shut off'. The automatic cooling is therefore a prerequisite for the autonomy and the fault tolerance of the system.

  14. SU-G-BRB-11: On the Sensitivity of An EPID-Based 3D Dose Verification System to Detect Delivery Errors in VMAT Treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, P; Olaciregui-Ruiz, I; Mijnheer, B

    2016-06-15

    Purpose: To investigate the sensitivity of an EPID-based 3D dose verification system to detect delivery errors in VMAT treatments. Methods: For this study 41 EPID-reconstructed 3D in vivo dose distributions of 15 different VMAT plans (H&N, lung, prostate and rectum) were selected. To simulate the effect of delivery errors, their TPS plans were modified by: 1) scaling of the monitor units by ±3% and ±6% and 2) systematic shifting of leaf bank positions by ±1mm, ±2mm and ±5mm. The 3D in vivo dose distributions where then compared to the unmodified and modified treatment plans. To determine the detectability of themore » various delivery errors, we made use of a receiver operator characteristic (ROC) methodology. True positive and false positive rates were calculated as a function of the γ-parameters γmean, γ1% (near-maximum γ) and the PTV dose parameter ΔD{sub 50} (i.e. D{sub 50}(EPID)-D{sub 50}(TPS)). The ROC curve is constructed by plotting the true positive rate vs. the false positive rate. The area under the ROC curve (AUC) then serves as a measure of the performance of the EPID dosimetry system in detecting a particular error; an ideal system has AUC=1. Results: The AUC ranges for the machine output errors and systematic leaf position errors were [0.64 – 0.93] and [0.48 – 0.92] respectively using γmean, [0.57 – 0.79] and [0.46 – 0.85] using γ1% and [0.61 – 0.77] and [ 0.48 – 0.62] using ΔD{sub 50}. Conclusion: For the verification of VMAT deliveries, the parameter γmean is the best discriminator for the detection of systematic leaf position errors and monitor unit scaling errors. Compared to γmean and γ1%, the parameter ΔD{sub 50} performs worse as a discriminator in all cases.« less

  15. The relationship between tree canopy and crime rates across an urban-rural gradient in the greater Baltimore region

    Treesearch

    Austin Troy; J. Morgan Grove; Jarlath O' Neill-Dunne

    2012-01-01

    The extent to which urban tree cover influences crime is in debate in the literature. This research took advantage of geocoded crime point data and high resolution tree canopy data to address this question in Baltimore City and County, MD, an area that includes a significant urban-rural gradient. Using ordinary least squares and spatially adjusted regression and...

  16. Disparities of Shigellosis Rates among California Children by Race/Ethnicity and Census Tract Poverty Level, 2000-2010.

    PubMed

    Jackson, Rebecca; Smith, Daniel; Tabnak, Farzaneh; Vugia, Duc

    2015-08-01

    We examined surveillance data for disparities in shigellosis rates among children by census tract (CT) poverty level and race/ethnicity in California. We geocoded addresses of 9740 children younger than 15 years of age from 2000-2010 California shigellosis surveillance data and calculated incidence rate (IR) per 100,000 population by age group and race/ethnicity. We linked geocoded cases to 2006-2010 American Community Survey CT-level poverty data and used IR ratios to compare children in the most impoverished CTs with those in the least impoverished CTs. The contribution of socioeconomic inequalities to age-standardized racial and ethnic disparities was explored using Poisson regression. Per 100,000 population, shigellosis IR was highest among California children less than 5 years old (16.4) and of Hispanic ethnicity (15.2). The age-standardized IR was 22.3 per 100,000 person-years in CTs with more than 40% of the population below the poverty line and 4.1 per 100,000 person-years in CTs with less than 5% of the population below the poverty line, an IR ratio of 5.8 (95% confidence interval: 5.2, 6.5). Shigellosis rates among California children were highest among Hispanics and increased with CT poverty.

  17. Sensitivity in error detection of patient specific QA tools for IMRT plans

    NASA Astrophysics Data System (ADS)

    Lat, S. Z.; Suriyapee, S.; Sanghangthum, T.

    2016-03-01

    The high complexity of dose calculation in treatment planning and accurate delivery of IMRT plan need high precision of verification method. The purpose of this study is to investigate error detection capability of patient specific QA tools for IMRT plans. The two H&N and two prostate IMRT plans with MapCHECK2 and portal dosimetry QA tools were studied. Measurements were undertaken for original and modified plans with errors introduced. The intentional errors composed of prescribed dose (±2 to ±6%) and position shifting in X-axis and Y-axis (±1 to ±5mm). After measurement, gamma pass between original and modified plans were compared. The average gamma pass for original H&N and prostate plans were 98.3% and 100% for MapCHECK2 and 95.9% and 99.8% for portal dosimetry, respectively. In H&N plan, MapCHECK2 can detect position shift errors starting from 3mm while portal dosimetry can detect errors started from 2mm. Both devices showed similar sensitivity in detection of position shift error in prostate plan. For H&N plan, MapCHECK2 can detect dose errors starting at ±4%, whereas portal dosimetry can detect from ±2%. For prostate plan, both devices can identify dose errors starting from ±4%. Sensitivity of error detection depends on type of errors and plan complexity.

  18. Helicopter force-feel and stability augmentation system with parallel servo-actuator

    NASA Technical Reports Server (NTRS)

    Hoh, Roger H. (Inventor)

    2006-01-01

    A force-feel system is implemented by mechanically coupling a servo-actuator to and in parallel with a flight control system. The servo-actuator consists of an electric motor, a gearing device, and a clutch. A commanded cockpit-flight-controller position is achieved by pilot actuation of a trim-switch. The position of the cockpit-flight-controller is compared with the commanded position to form a first error which is processed by a shaping function to correlate the first error with a commanded force at the cockpit-flight-controller. The commanded force on the cockpit-flight-controller provides centering forces and improved control feel for the pilot. In an embodiment, the force-feel system is used as the basic element of stability augmentation system (SAS). The SAS provides a stabilization signal that is compared with the commanded position to form a second error signal. The first error is summed with the second error for processing by the shaping function.

  19. A path reconstruction method integrating dead-reckoning and position fixes applied to humpback whales.

    PubMed

    Wensveen, Paul J; Thomas, Len; Miller, Patrick J O

    2015-01-01

    Detailed information about animal location and movement is often crucial in studies of natural behaviour and how animals respond to anthropogenic activities. Dead-reckoning can be used to infer such detailed information, but without additional positional data this method results in uncertainty that grows with time. Combining dead-reckoning with new Fastloc-GPS technology should provide good opportunities for reconstructing georeferenced fine-scale tracks, and should be particularly useful for marine animals that spend most of their time under water. We developed a computationally efficient, Bayesian state-space modelling technique to estimate humpback whale locations through time, integrating dead-reckoning using on-animal sensors with measurements of whale locations using on-animal Fastloc-GPS and visual observations. Positional observation models were based upon error measurements made during calibrations. High-resolution 3-dimensional movement tracks were produced for 13 whales using a simple process model in which errors caused by water current movements, non-location sensor errors, and other dead-reckoning errors were accumulated into a combined error term. Positional uncertainty quantified by the track reconstruction model was much greater for tracks with visual positions and few or no GPS positions, indicating a strong benefit to using Fastloc-GPS for track reconstruction. Compared to tracks derived only from position fixes, the inclusion of dead-reckoning data greatly improved the level of detail in the reconstructed tracks of humpback whales. Using cross-validation, a clear improvement in the predictability of out-of-set Fastloc-GPS data was observed compared to more conventional track reconstruction methods. Fastloc-GPS observation errors during calibrations were found to vary by number of GPS satellites received and by orthogonal dimension analysed; visual observation errors varied most by distance to the whale. By systematically accounting for the observation errors in the position fixes, our model provides a quantitative estimate of location uncertainty that can be appropriately incorporated into analyses of animal movement. This generic method has potential application for a wide range of marine animal species and data recording systems.

  20. Multilevel modelling of built environment characteristics related to neighbourhood walking activity in older adults

    PubMed Central

    Li, F.; Fisher, K; Brownson, R.; Bosworth, M.

    2005-01-01

    Objective: To examine the relation between built environment factors (representing several dimensions of urban form of neighbourhoods) and walking activity at both the neighbourhood level and the resident level, in an older adult sample. Design, setting, participants: A cross sectional, multilevel design with neighbourhoods as the primary sampling unit and senior residents as the secondary unit. Five hundred and seventy seven residents (mean age = 74 years, SD = 6.3 years) participated in the survey, which was conducted among 56 city defined neighbourhoods in Portland, Oregon, USA. Neighbourhood level variables were constructed using geographical information systems. Resident level variables consisted of a mix of self reports and geocoded data on the built environment. Main outcome measure: Self reported neighbourhood walking. Main results: A positive relation was found between built environment factors (density of places of employment, household density, green and open spaces for recreation, number of street intersections) and walking activity at the neighbourhood level. At the resident level, perceptions of safety for walking and number of nearby recreational facilities were positively related to high levels of walking activity. A significant interaction was observed between number of street intersections and perceptions of safety from traffic. Conclusions: Certain neighbourhood built environment characteristics related to urban form were positively associated with walking activity in the neighbourhoods of senior residents. Public health promotion of walking activity/urban mobility and the design of interventions need to consider the contribution of neighbourhood level built environment influences. PMID:15965138

  1. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures.

    PubMed

    Pan, Hong-Wei; Li, Wei; Li, Rong-Guo; Li, Yong; Zhang, Yi; Sun, En-Hua

    2018-01-01

    Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  2. Toward attenuating the impact of arm positions on electromyography pattern-recognition based motion classification in transradial amputees

    PubMed Central

    2012-01-01

    Background Electromyography (EMG) pattern-recognition based control strategies for multifunctional myoelectric prosthesis systems have been studied commonly in a controlled laboratory setting. Before these myoelectric prosthesis systems are clinically viable, it will be necessary to assess the effect of some disparities between the ideal laboratory setting and practical use on the control performance. One important obstacle is the impact of arm position variation that causes the changes of EMG pattern when performing identical motions in different arm positions. This study aimed to investigate the impacts of arm position variation on EMG pattern-recognition based motion classification in upper-limb amputees and the solutions for reducing these impacts. Methods With five unilateral transradial (TR) amputees, the EMG signals and tri-axial accelerometer mechanomyography (ACC-MMG) signals were simultaneously collected from both amputated and intact arms when performing six classes of arm and hand movements in each of five arm positions that were considered in the study. The effect of the arm position changes was estimated in terms of motion classification error and compared between amputated and intact arms. Then the performance of three proposed methods in attenuating the impact of arm positions was evaluated. Results With EMG signals, the average intra-position and inter-position classification errors across all five arm positions and five subjects were around 7.3% and 29.9% from amputated arms, respectively, about 1.0% and 10% low in comparison with those from intact arms. While ACC-MMG signals could yield a similar intra-position classification error (9.9%) as EMG, they had much higher inter-position classification error with an average value of 81.1% over the arm positions and the subjects. When the EMG data from all five arm positions were involved in the training set, the average classification error reached a value of around 10.8% for amputated arms. Using a two-stage cascade classifier, the average classification error was around 9.0% over all five arm positions. Reducing ACC-MMG channels from 8 to 2 only increased the average position classification error across all five arm positions from 0.7% to 1.0% in amputated arms. Conclusions The performance of EMG pattern-recognition based method in classifying movements strongly depends on arm positions. This dependency is a little stronger in intact arm than in amputated arm, which suggests that the investigations associated with practical use of a myoelectric prosthesis should use the limb amputees as subjects instead of using able-body subjects. The two-stage cascade classifier mode with ACC-MMG for limb position identification and EMG for limb motion classification may be a promising way to reduce the effect of limb position variation on classification performance. PMID:23036049

  3. Investigation of writing error in staggered heated-dot magnetic recording systems

    NASA Astrophysics Data System (ADS)

    Tipcharoen, W.; Warisarn, C.; Tongsomporn, D.; Karns, D.; Kovintavewat, P.

    2017-05-01

    To achieve an ultra-high storage capacity, heated-dot magnetic recording (HDMR) has been proposed, which heats a bit-patterned medium before recording data. Generally, an error during the HDMR writing process comes from several sources; however, we only investigate the effects of staggered island arrangement, island size fluctuation caused by imperfect fabrication, and main pole position fluctuation. Simulation results demonstrate that a writing error can be minimized by using a staggered array (hexagonal lattice) instead of a square array. Under the effect of main pole position fluctuation, the writing error is higher than the system without main pole position fluctuation. Finally, we found that the error percentage can drop below 10% when the island size is 8.5 nm and the standard deviation of the island size is 1 nm in the absence of main pole jitter.

  4. An Upper Bound on High Speed Satellite Collision Probability When Only One Object has Position Uncertainty Information

    NASA Technical Reports Server (NTRS)

    Frisbee, Joseph H., Jr.

    2015-01-01

    Upper bounds on high speed satellite collision probability, PC †, have been investigated. Previous methods assume an individual position error covariance matrix is available for each object. The two matrices being combined into a single, relative position error covariance matrix. Components of the combined error covariance are then varied to obtain a maximum PC. If error covariance information for only one of the two objects was available, either some default shape has been used or nothing could be done. An alternative is presented that uses the known covariance information along with a critical value of the missing covariance to obtain an approximate but potentially useful Pc upper bound.

  5. Access to emergency hospital care provided by the public sector in sub-Saharan Africa in 2015: a geocoded inventory and spatial analysis.

    PubMed

    Ouma, Paul O; Maina, Joseph; Thuranira, Pamela N; Macharia, Peter M; Alegana, Victor A; English, Mike; Okiro, Emelda A; Snow, Robert W

    2018-03-01

    Timely access to emergency care can substantially reduce mortality. International benchmarks for access to emergency hospital care have been established to guide ambitions for universal health care by 2030. However, no Pan-African database of where hospitals are located exists; therefore, we aimed to complete a geocoded inventory of hospital services in Africa in relation to how populations might access these services in 2015, with focus on women of child bearing age. We assembled a geocoded inventory of public hospitals across 48 countries and islands of sub-Saharan Africa, including Zanzibar, using data from various sources. We only included public hospitals with emergency services that were managed by governments at national or local levels and faith-based or non-governmental organisations. For hospital listings without geographical coordinates, we geocoded each facility using Microsoft Encarta (version 2009), Google Earth (version 7.3), Geonames, Fallingrain, OpenStreetMap, and other national digital gazetteers. We obtained estimates for total population and women of child bearing age (15-49 years) at a 1 km 2 spatial resolution from the WorldPop database for 2015. Additionally, we assembled road network data from Google Map Maker Project and OpenStreetMap using ArcMap (version 10.5). We then combined the road network and the population locations to form a travel impedance surface. Subsequently, we formulated a cost distance algorithm based on the location of public hospitals and the travel impedance surface in AccessMod (version 5) to compute the proportion of populations living within a combined walking and motorised travel time of 2 h to emergency hospital services. We consulted 100 databases from 48 sub-Saharan countries and islands, including Zanzibar, and identified 4908 public hospitals. 2701 hospitals had either full or partial information about their geographical coordinates. We estimated that 287 282 013 (29·0%) people and 64 495 526 (28·2%) women of child bearing age are located more than 2-h travel time from the nearest hospital. Marked differences were observed within and between countries, ranging from less than 25% of the population within 2-h travel time of a public hospital in South Sudan to more than 90% in Nigeria, Kenya, Cape Verde, Swaziland, South Africa, Burundi, Comoros, São Tomé and Príncipe, and Zanzibar. Only 16 countries reached the international benchmark of more than 80% of their populations living within a 2-h travel time of the nearest hospital. Physical access to emergency hospital care provided by the public sector in Africa remains poor and varies substantially within and between countries. Innovative targeting of emergency care services is necessary to reduce these inequities. This study provides the first spatial census of public hospital services in Africa. Wellcome Trust and the UK Department for International Development. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

  6. Error Types and Error Positions in Neglect Dyslexia: Comparative Analyses in Neglect Patients and Healthy Controls

    ERIC Educational Resources Information Center

    Weinzierl, Christiane; Kerkhoff, Georg; van Eimeren, Lucia; Keller, Ingo; Stenneken, Prisca

    2012-01-01

    Unilateral spatial neglect frequently involves a lateralised reading disorder, neglect dyslexia (ND). Reading of single words in ND is characterised by left-sided omissions and substitutions of letters. However, it is unclear whether the distribution of error types and positions within a word shows a unique pattern of ND when directly compared to…

  7. Catch-up saccades in head-unrestrained conditions reveal that saccade amplitude is corrected using an internal model of target movement

    PubMed Central

    Daye, Pierre M.; Blohm, Gunnar; Lefèvre, Phillippe

    2014-01-01

    This study analyzes how human participants combine saccadic and pursuit gaze movements when they track an oscillating target moving along a randomly oriented straight line with the head free to move. We found that to track the moving target appropriately, participants triggered more saccades with increasing target oscillation frequency to compensate for imperfect tracking gains. Our sinusoidal paradigm allowed us to show that saccade amplitude was better correlated with internal estimates of position and velocity error at saccade onset than with those parameters 100 ms before saccade onset as head-restrained studies have shown. An analysis of saccadic onset time revealed that most of the saccades were triggered when the target was accelerating. Finally, we found that most saccades were triggered when small position errors were combined with large velocity errors at saccade onset. This could explain why saccade amplitude was better correlated with velocity error than with position error. Therefore, our results indicate that the triggering mechanism of head-unrestrained catch-up saccades combines position and velocity error at saccade onset to program and correct saccade amplitude rather than using sensory information 100 ms before saccade onset. PMID:24424378

  8. A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Damato, Antonio L., E-mail: adamato@lroc.harvard.edu; Viswanathan, Akila N.; Don, Sarah M.

    2014-10-15

    Purpose: To investigate the use of a system using electromagnetic tracking (EMT), post-processing and an error-detection algorithm for detecting errors and resolving uncertainties in high-dose-rate brachytherapy catheter digitization for treatment planning. Methods: EMT was used to localize 15 catheters inserted into a phantom using a stepwise acquisition technique. Five distinct acquisition experiments were performed. Noise associated with the acquisition was calculated. The dwell location configuration was extracted from the EMT data. A CT scan of the phantom was performed, and five distinct catheter digitization sessions were performed. No a priori registration of the CT scan coordinate system with the EMTmore » coordinate system was performed. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT), and rigid registration was performed between EMT and CT dwell positions. EMT registration error was characterized in terms of the mean and maximum distance between corresponding EMT and CT dwell positions per catheter. An algorithm for error detection and identification was presented. Three types of errors were systematically simulated: swap of two catheter numbers, partial swap of catheter number identification for parts of the catheters (mix), and catheter-tip shift. Error-detection sensitivity (number of simulated scenarios correctly identified as containing an error/number of simulated scenarios containing an error) and specificity (number of scenarios correctly identified as not containing errors/number of correct scenarios) were calculated. Catheter identification sensitivity (number of catheters correctly identified as erroneous across all scenarios/number of erroneous catheters across all scenarios) and specificity (number of catheters correctly identified as correct across all scenarios/number of correct catheters across all scenarios) were calculated. The mean detected and identified shift was calculated. Results: The maximum noise ±1 standard deviation associated with the EMT acquisitions was 1.0 ± 0.1 mm, and the mean noise was 0.6 ± 0.1 mm. Registration of all the EMT and CT dwell positions was associated with a mean catheter error of 0.6 ± 0.2 mm, a maximum catheter error of 0.9 ± 0.4 mm, a mean dwell error of 1.0 ± 0.3 mm, and a maximum dwell error of 1.3 ± 0.7 mm. Error detection and catheter identification sensitivity and specificity of 100% were observed for swap, mix and shift (≥2.6 mm for error detection; ≥2.7 mm for catheter identification) errors. A mean detected shift of 1.8 ± 0.4 mm and a mean identified shift of 1.9 ± 0.4 mm were observed. Conclusions: Registration of the EMT dwell positions to the CT dwell positions was possible with a residual mean error per catheter of 0.6 ± 0.2 mm and a maximum error for any dwell of 1.3 ± 0.7 mm. These low residual registration errors show that quality assurance of the general characteristics of the catheters and of possible errors affecting one specific dwell position is possible. The sensitivity and specificity of the catheter digitization verification algorithm was 100% for swap and mix errors and for shifts ≥2.6 mm. On average, shifts ≥1.8 mm were detected, and shifts ≥1.9 mm were detected and identified.« less

  9. Refraction corrected calibration for aquatic locomotion research: application of Snell's law improves spatial accuracy.

    PubMed

    Henrion, Sebastian; Spoor, Cees W; Pieters, Remco P M; Müller, Ulrike K; van Leeuwen, Johan L

    2015-07-07

    Images of underwater objects are distorted by refraction at the water-glass-air interfaces and these distortions can lead to substantial errors when reconstructing the objects' position and shape. So far, aquatic locomotion studies have minimized refraction in their experimental setups and used the direct linear transform algorithm (DLT) to reconstruct position information, which does not model refraction explicitly. Here we present a refraction corrected ray-tracing algorithm (RCRT) that reconstructs position information using Snell's law. We validated this reconstruction by calculating 3D reconstruction error-the difference between actual and reconstructed position of a marker. We found that reconstruction error is small (typically less than 1%). Compared with the DLT algorithm, the RCRT has overall lower reconstruction errors, especially outside the calibration volume, and errors are essentially insensitive to camera position and orientation and the number and position of the calibration points. To demonstrate the effectiveness of the RCRT, we tracked an anatomical marker on a seahorse recorded with four cameras to reconstruct the swimming trajectory for six different camera configurations. The RCRT algorithm is accurate and robust and it allows cameras to be oriented at large angles of incidence and facilitates the development of accurate tracking algorithms to quantify aquatic manoeuvers.

  10. Dental Students' Interpretations of Digital Panoramic Radiographs on Completely Edentate Patients.

    PubMed

    Kratz, Richard J; Nguyen, Caroline T; Walton, Joanne N; MacDonald, David

    2018-03-01

    The ability of dental students to interpret digital panoramic radiographs (PANs) of edentulous patients has not been documented. The aim of this retrospective study was to compare the ability of second-year (D2) dental students with that of third- and fourth-year (D3-D4) dental students to interpret and identify positional errors in digital PANs obtained from patients with complete edentulism. A total of 169 digital PANs from edentulous patients were assessed by D2 (n=84) and D3-D4 (n=85) dental students at one Canadian dental school. The correctness of the students' interpretations was determined by comparison to a gold standard established by assessments of the same PANs by two experts (a graduate student in prosthodontics and an oral and maxillofacial radiologist). Data collected were from September 1, 2006, when digital radiography was implemented at the university, to December 31, 2012. Nearly all (95%) of the PANs were acceptable diagnostically despite a high proportion (92%) of positional errors detected. A total of 301 positional errors were identified in the sample. The D2 students identified significantly more (p=0.002) positional errors than the D3-D4 students. There was no significant difference (p=0.059) in the distribution of radiographic interpretation errors between the two student groups when compared to the gold standard. Overall, the category of extragnathic findings had the highest number of false negatives (43) reported. In this study, dental students interpreted digital PANs of edentulous patients satisfactorily, but they were more adept at identifying radiographic findings compared to positional errors. Students should be reminded to examine the entire radiograph thoroughly to ensure extragnathic findings are not missed and to recognize and report patient positional errors.

  11. Unmodeled observation error induces bias when inferring patterns and dynamics of species occurrence via aural detections

    USGS Publications Warehouse

    McClintock, Brett T.; Bailey, Larissa L.; Pollock, Kenneth H.; Simons, Theodore R.

    2010-01-01

    The recent surge in the development and application of species occurrence models has been associated with an acknowledgment among ecologists that species are detected imperfectly due to observation error. Standard models now allow unbiased estimation of occupancy probability when false negative detections occur, but this is conditional on no false positive detections and sufficient incorporation of explanatory variables for the false negative detection process. These assumptions are likely reasonable in many circumstances, but there is mounting evidence that false positive errors and detection probability heterogeneity may be much more prevalent in studies relying on auditory cues for species detection (e.g., songbird or calling amphibian surveys). We used field survey data from a simulated calling anuran system of known occupancy state to investigate the biases induced by these errors in dynamic models of species occurrence. Despite the participation of expert observers in simplified field conditions, both false positive errors and site detection probability heterogeneity were extensive for most species in the survey. We found that even low levels of false positive errors, constituting as little as 1% of all detections, can cause severe overestimation of site occupancy, colonization, and local extinction probabilities. Further, unmodeled detection probability heterogeneity induced substantial underestimation of occupancy and overestimation of colonization and local extinction probabilities. Completely spurious relationships between species occurrence and explanatory variables were also found. Such misleading inferences would likely have deleterious implications for conservation and management programs. We contend that all forms of observation error, including false positive errors and heterogeneous detection probabilities, must be incorporated into the estimation framework to facilitate reliable inferences about occupancy and its associated vital rate parameters.

  12. Sex differences in the shoulder joint position sense acuity: a cross-sectional study.

    PubMed

    Vafadar, Amir K; Côté, Julie N; Archambault, Philippe S

    2015-09-30

    Work-related musculoskeletal disorders (WMSD) is the most expensive form of work disability. Female sex has been considered as an individual risk factor for the development of WMSD, specifically in the neck and shoulder region. One of the factors that might contribute to the higher injury rate in women is possible differences in neuromuscular control. Accordingly the purpose of this study was to estimate the effect of sex on shoulder joint position sense acuity (as a part of shoulder neuromuscular control) in healthy individuals. Twenty-eight healthy participants, 14 females and 14 males were recruited for this study. To test position sense acuity, subjects were asked to flex their dominant shoulder to one of the three pre-defined angle ranges (low, mid and high-ranges) with eyes closed, hold their arm in that position for three seconds, go back to the starting position and then immediately replicate the same joint flexion angle, while the difference between the reproduced and original angle was taken as the measure of position sense error. The errors were measured using Vicon motion capture system. Subjects reproduced nine positions in total (3 ranges × 3 trials each). Calculation of absolute repositioning error (magnitude of error) showed no significant difference between men and women (p-value ≥ 0.05). However, the analysis of the direction of error (constant error) showed a significant difference between the sexes, as women tended to mostly overestimate the target, whereas men tended to both overestimate and underestimate the target (p-value ≤ 0.01, observed power = 0.79). The results also showed that men had a significantly more variable error, indicating more variability in their position sense, compared to women (p-value ≤ 0.05, observed power = 0.78). Differences observed in the constant JPS error suggest that men and women might use different neuromuscular control strategies in the upper limb. In addition, higher JPS variability observed in men might be one of the factors that could contribute to their lower rate of musculoskeletal disorders, compared to women. The result of this study showed that shoulder position sense, as part of the neuromuscular control system, differs between men and women. This finding can help us better understand the reasons behind the higher rate of musculoskeletal disorders in women, especially in the working environments.

  13. Improving Localization Accuracy: Successive Measurements Error Modeling

    PubMed Central

    Abu Ali, Najah; Abu-Elkheir, Mervat

    2015-01-01

    Vehicle self-localization is an essential requirement for many of the safety applications envisioned for vehicular networks. The mathematical models used in current vehicular localization schemes focus on modeling the localization error itself, and overlook the potential correlation between successive localization measurement errors. In this paper, we first investigate the existence of correlation between successive positioning measurements, and then incorporate this correlation into the modeling positioning error. We use the Yule Walker equations to determine the degree of correlation between a vehicle’s future position and its past positions, and then propose a p-order Gauss–Markov model to predict the future position of a vehicle from its past p positions. We investigate the existence of correlation for two datasets representing the mobility traces of two vehicles over a period of time. We prove the existence of correlation between successive measurements in the two datasets, and show that the time correlation between measurements can have a value up to four minutes. Through simulations, we validate the robustness of our model and show that it is possible to use the first-order Gauss–Markov model, which has the least complexity, and still maintain an accurate estimation of a vehicle’s future location over time using only its current position. Our model can assist in providing better modeling of positioning errors and can be used as a prediction tool to improve the performance of classical localization algorithms such as the Kalman filter. PMID:26140345

  14. Robust Adaptive Beamforming with Sensor Position Errors Using Weighted Subspace Fitting-Based Covariance Matrix Reconstruction.

    PubMed

    Chen, Peng; Yang, Yixin; Wang, Yong; Ma, Yuanliang

    2018-05-08

    When sensor position errors exist, the performance of recently proposed interference-plus-noise covariance matrix (INCM)-based adaptive beamformers may be severely degraded. In this paper, we propose a weighted subspace fitting-based INCM reconstruction algorithm to overcome sensor displacement for linear arrays. By estimating the rough signal directions, we construct a novel possible mismatched steering vector (SV) set. We analyze the proximity of the signal subspace from the sample covariance matrix (SCM) and the space spanned by the possible mismatched SV set. After solving an iterative optimization problem, we reconstruct the INCM using the estimated sensor position errors. Then we estimate the SV of the desired signal by solving an optimization problem with the reconstructed INCM. The main advantage of the proposed algorithm is its robustness against SV mismatches dominated by unknown sensor position errors. Numerical examples show that even if the position errors are up to half of the assumed sensor spacing, the output signal-to-interference-plus-noise ratio is only reduced by 4 dB. Beam patterns plotted using experiment data show that the interference suppression capability of the proposed beamformer outperforms other tested beamformers.

  15. Error analysis of 3D-PTV through unsteady interfaces

    NASA Astrophysics Data System (ADS)

    Akutina, Yulia; Mydlarski, Laurent; Gaskin, Susan; Eiff, Olivier

    2018-03-01

    The feasibility of stereoscopic flow measurements through an unsteady optical interface is investigated. Position errors produced by a wavy optical surface are determined analytically, as are the optimal viewing angles of the cameras to minimize such errors. Two methods of measuring the resulting velocity errors are proposed. These methods are applied to 3D particle tracking velocimetry (3D-PTV) data obtained through the free surface of a water flow within a cavity adjacent to a shallow channel. The experiments were performed using two sets of conditions, one having no strong surface perturbations, and the other exhibiting surface gravity waves. In the latter case, the amplitude of the gravity waves was 6% of the water depth, resulting in water surface inclinations of about 0.2°. (The water depth is used herein as a relevant length scale, because the measurements are performed in the entire water column. In a more general case, the relevant scale is the maximum distance from the interface to the measurement plane, H, which here is the same as the water depth.) It was found that the contribution of the waves to the overall measurement error is low. The absolute position errors of the system were moderate (1.2% of H). However, given that the velocity is calculated from the relative displacement of a particle between two frames, the errors in the measured water velocities were reasonably small, because the error in the velocity is the relative position error over the average displacement distance. The relative position error was measured to be 0.04% of H, resulting in small velocity errors of 0.3% of the free-stream velocity (equivalent to 1.1% of the average velocity in the domain). It is concluded that even though the absolute positions to which the velocity vectors are assigned is distorted by the unsteady interface, the magnitude of the velocity vectors themselves remains accurate as long as the waves are slowly varying (have low curvature). The stronger the disturbances on the interface are (high amplitude, short wave length), the smaller is the distance from the interface at which the measurements can be performed.

  16. Comparison of survey and photogrammetry methods to position gravity data, Yucca Mountain, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ponce, D.A.; Wu, S.S.C.; Spielman, J.B.

    1985-12-31

    Locations of gravity stations at Yucca Mountain, Nevada, were determined by a survey using an electronic distance-measuring device and by a photogram-metric method. The data from both methods were compared to determine if horizontal and vertical coordinates developed from photogrammetry are sufficently accurate to position gravity data at the site. The results show that elevations from the photogrammetric data have a mean difference of 0.57 +- 0.70 m when compared with those of the surveyed data. Comparison of the horizontal control shows that the two methods agreed to within 0.01 minute. At a latitude of 45{sup 0}, an error ofmore » 0.01 minute (18 m) corresponds to a gravity anomaly error of 0.015 mGal. Bouguer gravity anomalies are most sensitive to errors in elevation, thus elevation is the determining factor for use of photogrammetric or survey methods to position gravity data. Because gravity station positions are difficult to locate on aerial photographs, photogrammetric positions are not always exactly at the gravity station; therefore, large disagreements may appear when comparing electronic and photogrammetric measurements. A mean photogrammetric elevation error of 0.57 m corresponds to a gravity anomaly error of 0.11 mGal. Errors of 0.11 mGal are too large for high-precision or detailed gravity measurements but acceptable for regional work. 1 ref. 2 figs., 4 tabs.« less

  17. A simulation study to quantify the impacts of exposure measurement error on air pollution health risk estimates in copollutant time-series models.

    PubMed

    Dionisio, Kathie L; Chang, Howard H; Baxter, Lisa K

    2016-11-25

    Exposure measurement error in copollutant epidemiologic models has the potential to introduce bias in relative risk (RR) estimates. A simulation study was conducted using empirical data to quantify the impact of correlated measurement errors in time-series analyses of air pollution and health. ZIP-code level estimates of exposure for six pollutants (CO, NO x , EC, PM 2.5 , SO 4 , O 3 ) from 1999 to 2002 in the Atlanta metropolitan area were used to calculate spatial, population (i.e. ambient versus personal), and total exposure measurement error. Empirically determined covariance of pollutant concentration pairs and the associated measurement errors were used to simulate true exposure (exposure without error) from observed exposure. Daily emergency department visits for respiratory diseases were simulated using a Poisson time-series model with a main pollutant RR = 1.05 per interquartile range, and a null association for the copollutant (RR = 1). Monte Carlo experiments were used to evaluate the impacts of correlated exposure errors of different copollutant pairs. Substantial attenuation of RRs due to exposure error was evident in nearly all copollutant pairs studied, ranging from 10 to 40% attenuation for spatial error, 3-85% for population error, and 31-85% for total error. When CO, NO x or EC is the main pollutant, we demonstrated the possibility of false positives, specifically identifying significant, positive associations for copollutants based on the estimated type I error rate. The impact of exposure error must be considered when interpreting results of copollutant epidemiologic models, due to the possibility of attenuation of main pollutant RRs and the increased probability of false positives when measurement error is present.

  18. Sensitivity and specificity of dosing alerts for dosing errors among hospitalized pediatric patients

    PubMed Central

    Stultz, Jeremy S; Porter, Kyle; Nahata, Milap C

    2014-01-01

    Objectives To determine the sensitivity and specificity of a dosing alert system for dosing errors and to compare the sensitivity of a proprietary system with and without institutional customization at a pediatric hospital. Methods A retrospective analysis of medication orders, orders causing dosing alerts, reported adverse drug events, and dosing errors during July, 2011 was conducted. Dosing errors with and without alerts were identified and the sensitivity of the system with and without customization was compared. Results There were 47 181 inpatient pediatric orders during the studied period; 257 dosing errors were identified (0.54%). The sensitivity of the system for identifying dosing errors was 54.1% (95% CI 47.8% to 60.3%) if customization had not occurred and increased to 60.3% (CI 54.0% to 66.3%) with customization (p=0.02). The sensitivity of the system for underdoses was 49.6% without customization and 60.3% with customization (p=0.01). Specificity of the customized system for dosing errors was 96.2% (CI 96.0% to 96.3%) with a positive predictive value of 8.0% (CI 6.8% to 9.3). All dosing errors had an alert over-ridden by the prescriber and 40.6% of dosing errors with alerts were administered to the patient. The lack of indication-specific dose ranges was the most common reason why an alert did not occur for a dosing error. Discussion Advances in dosing alert systems should aim to improve the sensitivity and positive predictive value of the system for dosing errors. Conclusions The dosing alert system had a low sensitivity and positive predictive value for dosing errors, but might have prevented dosing errors from reaching patients. Customization increased the sensitivity of the system for dosing errors. PMID:24496386

  19. Spatial and temporal variation in the association between temperature and salmonellosis in NZ.

    PubMed

    Lal, Aparna; Hales, Simon; Kirk, Martyn; Baker, Michael G; French, Nigel P

    2016-04-01

    Modelling the relationship between weather, climate and infectious diseases can help identify high-risk periods and provide understanding of the determinants of longer-term trends. We provide a detailed examination of the non-linear and delayed association between temperature and salmonellosis in three New Zealand cities (Auckland, Wellington and Christchurch). Salmonella notifications were geocoded to the city of residence for the reported case. City-specific associations between weekly maximum temperature and the onset date for reported salmonella infections (1997-2007) were modelled using non-linear distributed lag models, while controlling for season and long-term trends. Relatively high temperatures were positively associated with infection risk in Auckland (n=3,073) and Christchurch (n=880), although the former showed evidence of a more immediate relationship with exposure to high temperatures. There was no significant association between temperature and salmonellosis risk in Wellington. Projected increases in temperature with climate change may have localised health impacts, suggesting that preventative measures will need to be region-specific. This evidence contributes to the increasing concern over the public health impacts of climate change. © 2015 Public Health Association of Australia.

  20. GPS-based microenvironment tracker (MicroTrac) model to estimate time–location of individuals for air pollution exposure assessments: Model evaluation in central North Carolina

    PubMed Central

    Breen, Michael S.; Long, Thomas C.; Schultz, Bradley D.; Crooks, James; Breen, Miyuki; Langstaff, John E.; Isaacs, Kristin K.; Tan, Yu-Mei; Williams, Ronald W.; Cao, Ye; Geller, Andrew M.; Devlin, Robert B.; Batterman, Stuart A.; Buckley, Timothy J.

    2014-01-01

    A critical aspect of air pollution exposure assessment is the estimation of the time spent by individuals in various microenvironments (ME). Accounting for the time spent in different ME with different pollutant concentrations can reduce exposure misclassifications, while failure to do so can add uncertainty and bias to risk estimates. In this study, a classification model, called MicroTrac, was developed to estimate time of day and duration spent in eight ME (indoors and outdoors at home, work, school; inside vehicles; other locations) from global positioning system (GPS) data and geocoded building boundaries. Based on a panel study, MicroTrac estimates were compared with 24-h diary data from nine participants, with corresponding GPS data and building boundaries of home, school, and work. MicroTrac correctly classified the ME for 99.5% of the daily time spent by the participants. The capability of MicroTrac could help to reduce the time–location uncertainty in air pollution exposure models and exposure metrics for individuals in health studies. PMID:24619294

  1. Geo-Coding for the Mapping of Documents and Social Media Messages

    DTIC Science & Technology

    2013-08-22

    O.L. (2007). UBC-ALM: Combining KNN with SVD for WSD. Proceedings of the 4th International Workshop on Semantic Evaluations (SemEval-2007), Prague...and Yarowsky, D. (1992). One sense per discourse. In Proceedings of the 4th DARPA Speech and Natural Language Workshop. pp. 233-237, 1992. Retrieved...Part-of- Speech Tagging for Twitter: Annotation, Features, and Experiments. Proceedings of the Annual Meeting of the Association for Computational

  2. Lane Level Localization; Using Images and HD Maps to Mitigate the Lateral Error

    NASA Astrophysics Data System (ADS)

    Hosseinyalamdary, S.; Peter, M.

    2017-05-01

    In urban canyon where the GNSS signals are blocked by buildings, the accuracy of measured position significantly deteriorates. GIS databases have been frequently utilized to improve the accuracy of measured position using map matching approaches. In map matching, the measured position is projected to the road links (centerlines) in this approach and the lateral error of measured position is reduced. By the advancement in data acquision approaches, high definition maps which contain extra information, such as road lanes are generated. These road lanes can be utilized to mitigate the positional error and improve the accuracy in position. In this paper, the image content of a camera mounted on the platform is utilized to detect the road boundaries in the image. We apply color masks to detect the road marks, apply the Hough transform to fit lines to the left and right road boundaries, find the corresponding road segment in GIS database, estimate the homography transformation between the global and image coordinates of the road boundaries, and estimate the camera pose with respect to the global coordinate system. The proposed approach is evaluated on a benchmark. The position is measured by a smartphone's GPS receiver, images are taken from smartphone's camera and the ground truth is provided by using Real-Time Kinematic (RTK) technique. Results show the proposed approach significantly improves the accuracy of measured GPS position. The error in measured GPS position with average and standard deviation of 11.323 and 11.418 meters is reduced to the error in estimated postion with average and standard deviation of 6.725 and 5.899 meters.

  3. A map overlay error model based on boundary geometry

    USGS Publications Warehouse

    Gaeuman, D.; Symanzik, J.; Schmidt, J.C.

    2005-01-01

    An error model for quantifying the magnitudes and variability of errors generated in the areas of polygons during spatial overlay of vector geographic information system layers is presented. Numerical simulation of polygon boundary displacements was used to propagate coordinate errors to spatial overlays. The model departs from most previous error models in that it incorporates spatial dependence of coordinate errors at the scale of the boundary segment. It can be readily adapted to match the scale of error-boundary interactions responsible for error generation on a given overlay. The area of error generated by overlay depends on the sinuosity of polygon boundaries, as well as the magnitude of the coordinate errors on the input layers. Asymmetry in boundary shape has relatively little effect on error generation. Overlay errors are affected by real differences in boundary positions on the input layers, as well as errors in the boundary positions. Real differences between input layers tend to compensate for much of the error generated by coordinate errors. Thus, the area of change measured on an overlay layer produced by the XOR overlay operation will be more accurate if the area of real change depicted on the overlay is large. The model presented here considers these interactions, making it especially useful for estimating errors studies of landscape change over time. ?? 2005 The Ohio State University.

  4. Mars approach navigation using Doppler and range measurements to surface beacons and orbiting spacecraft

    NASA Technical Reports Server (NTRS)

    Thurman, Sam W.; Estefan, Jeffrey A.

    1991-01-01

    Approximate analytical models are developed and used to construct an error covariance analysis for investigating the range of orbit determination accuracies which might be achieved for typical Mars approach trajectories. The sensitivity or orbit determination accuracy to beacon/orbiter position errors and to small spacecraft force modeling errors is also investigated. The results indicate that the orbit determination performance obtained from both Doppler and range data is a strong function of the inclination of the approach trajectory to the Martian equator, for surface beacons, and for orbiters, the inclination relative to the orbital plane. Large variations in performance were also observed for different approach velocity magnitudes; Doppler data in particular were found to perform poorly in determining the downtrack (along the direction of flight) component of spacecraft position. In addition, it was found that small spacecraft acceleration modeling errors can induce large errors in the Doppler-derived downtrack position estimate.

  5. Real-Time PPP Based on the Coupling Estimation of Clock Bias and Orbit Error with Broadcast Ephemeris.

    PubMed

    Pan, Shuguo; Chen, Weirong; Jin, Xiaodong; Shi, Xiaofei; He, Fan

    2015-07-22

    Satellite orbit error and clock bias are the keys to precise point positioning (PPP). The traditional PPP algorithm requires precise satellite products based on worldwide permanent reference stations. Such an algorithm requires considerable work and hardly achieves real-time performance. However, real-time positioning service will be the dominant mode in the future. IGS is providing such an operational service (RTS) and there are also commercial systems like Trimble RTX in operation. On the basis of the regional Continuous Operational Reference System (CORS), a real-time PPP algorithm is proposed to apply the coupling estimation of clock bias and orbit error. The projection of orbit error onto the satellite-receiver range has the same effects on positioning accuracy with clock bias. Therefore, in satellite clock estimation, part of the orbit error can be absorbed by the clock bias and the effects of residual orbit error on positioning accuracy can be weakened by the evenly distributed satellite geometry. In consideration of the simple structure of pseudorange equations and the high precision of carrier-phase equations, the clock bias estimation method coupled with orbit error is also improved. Rovers obtain PPP results by receiving broadcast ephemeris and real-time satellite clock bias coupled with orbit error. By applying the proposed algorithm, the precise orbit products provided by GNSS analysis centers are rendered no longer necessary. On the basis of previous theoretical analysis, a real-time PPP system was developed. Some experiments were then designed to verify this algorithm. Experimental results show that the newly proposed approach performs better than the traditional PPP based on International GNSS Service (IGS) real-time products. The positioning accuracies of the rovers inside and outside the network are improved by 38.8% and 36.1%, respectively. The PPP convergence speeds are improved by up to 61.4% and 65.9%. The new approach can change the traditional PPP mode because of its advantages of independence, high positioning precision, and real-time performance. It could be an alternative solution for regional positioning service before global PPP service comes into operation.

  6. Real-Time PPP Based on the Coupling Estimation of Clock Bias and Orbit Error with Broadcast Ephemeris

    PubMed Central

    Pan, Shuguo; Chen, Weirong; Jin, Xiaodong; Shi, Xiaofei; He, Fan

    2015-01-01

    Satellite orbit error and clock bias are the keys to precise point positioning (PPP). The traditional PPP algorithm requires precise satellite products based on worldwide permanent reference stations. Such an algorithm requires considerable work and hardly achieves real-time performance. However, real-time positioning service will be the dominant mode in the future. IGS is providing such an operational service (RTS) and there are also commercial systems like Trimble RTX in operation. On the basis of the regional Continuous Operational Reference System (CORS), a real-time PPP algorithm is proposed to apply the coupling estimation of clock bias and orbit error. The projection of orbit error onto the satellite-receiver range has the same effects on positioning accuracy with clock bias. Therefore, in satellite clock estimation, part of the orbit error can be absorbed by the clock bias and the effects of residual orbit error on positioning accuracy can be weakened by the evenly distributed satellite geometry. In consideration of the simple structure of pseudorange equations and the high precision of carrier-phase equations, the clock bias estimation method coupled with orbit error is also improved. Rovers obtain PPP results by receiving broadcast ephemeris and real-time satellite clock bias coupled with orbit error. By applying the proposed algorithm, the precise orbit products provided by GNSS analysis centers are rendered no longer necessary. On the basis of previous theoretical analysis, a real-time PPP system was developed. Some experiments were then designed to verify this algorithm. Experimental results show that the newly proposed approach performs better than the traditional PPP based on International GNSS Service (IGS) real-time products. The positioning accuracies of the rovers inside and outside the network are improved by 38.8% and 36.1%, respectively. The PPP convergence speeds are improved by up to 61.4% and 65.9%. The new approach can change the traditional PPP mode because of its advantages of independence, high positioning precision, and real-time performance. It could be an alternative solution for regional positioning service before global PPP service comes into operation. PMID:26205276

  7. Post-error Brain Activity Correlates With Incidental Memory for Negative Words

    PubMed Central

    Senderecka, Magdalena; Ociepka, Michał; Matyjek, Magdalena; Kroczek, Bartłomiej

    2018-01-01

    The present study had three main objectives. First, we aimed to evaluate whether short-duration affective states induced by negative and positive words can lead to increased error-monitoring activity relative to a neutral task condition. Second, we intended to determine whether such an enhancement is limited to words of specific valence or is a general response to arousing material. Third, we wanted to assess whether post-error brain activity is associated with incidental memory for negative and/or positive words. Participants performed an emotional stop-signal task that required response inhibition to negative, positive or neutral nouns while EEG was recorded. Immediately after the completion of the task, they were instructed to recall as many of the presented words as they could in an unexpected free recall test. We observed significantly greater brain activity in the error-positivity (Pe) time window in both negative and positive trials. The error-related negativity amplitudes were comparable in both the neutral and emotional arousing trials, regardless of their valence. Regarding behavior, increased processing of emotional words was reflected in better incidental recall. Importantly, the memory performance for negative words was positively correlated with the Pe amplitude, particularly in the negative condition. The source localization analysis revealed that the subsequent memory recall for negative words was associated with widespread bilateral brain activity in the dorsal anterior cingulate cortex and in the medial frontal gyrus, which was registered in the Pe time window during negative trials. The present study has several important conclusions. First, it indicates that the emotional enhancement of error monitoring, as reflected by the Pe amplitude, may be induced by stimuli with symbolic, ontogenetically learned emotional significance. Second, it indicates that the emotion-related enhancement of the Pe occurs across both negative and positive conditions, thus it is preferentially driven by the arousal content of an affective stimuli. Third, our findings suggest that enhanced error monitoring and facilitated recall of negative words may both reflect responsivity to negative events. More speculatively, they can also indicate that post-error activity of the medial prefrontal cortex may selectively support encoding for negative stimuli and contribute to their privileged access to memory. PMID:29867408

  8. Climbing fibers predict movement kinematics and performance errors.

    PubMed

    Streng, Martha L; Popa, Laurentiu S; Ebner, Timothy J

    2017-09-01

    Requisite for understanding cerebellar function is a complete characterization of the signals provided by complex spike (CS) discharge of Purkinje cells, the output neurons of the cerebellar cortex. Numerous studies have provided insights into CS function, with the most predominant view being that they are evoked by error events. However, several reports suggest that CSs encode other aspects of movements and do not always respond to errors or unexpected perturbations. Here, we evaluated CS firing during a pseudo-random manual tracking task in the monkey ( Macaca mulatta ). This task provides extensive coverage of the work space and relative independence of movement parameters, delivering a robust data set to assess the signals that activate climbing fibers. Using reverse correlation, we determined feedforward and feedback CSs firing probability maps with position, velocity, and acceleration, as well as position error, a measure of tracking performance. The direction and magnitude of the CS modulation were quantified using linear regression analysis. The major findings are that CSs significantly encode all three kinematic parameters and position error, with acceleration modulation particularly common. The modulation is not related to "events," either for position error or kinematics. Instead, CSs are spatially tuned and provide a linear representation of each parameter evaluated. The CS modulation is largely predictive. Similar analyses show that the simple spike firing is modulated by the same parameters as the CSs. Therefore, CSs carry a broader array of signals than previously described and argue for climbing fiber input having a prominent role in online motor control. NEW & NOTEWORTHY This article demonstrates that complex spike (CS) discharge of cerebellar Purkinje cells encodes multiple parameters of movement, including motor errors and kinematics. The CS firing is not driven by error or kinematic events; instead it provides a linear representation of each parameter. In contrast with the view that CSs carry feedback signals, the CSs are predominantly predictive of upcoming position errors and kinematics. Therefore, climbing fibers carry multiple and predictive signals for online motor control. Copyright © 2017 the American Physiological Society.

  9. Evaluation of dynamic electromagnetic tracking deviation

    NASA Astrophysics Data System (ADS)

    Hummel, Johann; Figl, Michael; Bax, Michael; Shahidi, Ramin; Bergmann, Helmar; Birkfellner, Wolfgang

    2009-02-01

    Electromagnetic tracking systems (EMTS's) are widely used in clinical applications. Many reports have evaluated their static behavior and errors caused by metallic objects were examined. Although there exist some publications concerning the dynamic behavior of EMTS's the measurement protocols are either difficult to reproduce with respect of the movement path or only accomplished at high technical effort. Because dynamic behavior is of major interest with respect to clinical applications we established a simple but effective modal measurement easy to repeat at other laboratories. We built a simple pendulum where the sensor of our EMTS (Aurora, NDI, CA) could be mounted. The pendulum was mounted on a special bearing to guarantee that the pendulum path is planar. This assumption was tested before starting the measurements. All relevant parameters defining the pendulum motion such as rotation center and length are determined by static measurement at satisfactory accuracy. Then position and orientation data were gathered over a time period of 8 seconds and timestamps were recorded. Data analysis provided a positioning error and an overall error combining both position and orientation. All errors were calculated by means of the well know equations concerning pendulum movement. Additionally, latency - the elapsed time from input motion until the immediate consequences of that input are available - was calculated using well-known equations for mechanical pendulums for different velocities. We repeated the measurements with different metal objects (rods made of stainless steel type 303 and 416) between field generator and pendulum. We found a root mean square error (eRMS) of 1.02mm with respect to the distance of the sensor position to the fit plane (maximum error emax = 2.31mm, minimum error emin = -2.36mm). The eRMS for positional error amounted to 1.32mm while the overall error was 3.24 mm. The latency at a pendulum angle of 0° (vertical) was 7.8ms.

  10. Analysis of Position Error Headway Protection

    DOT National Transportation Integrated Search

    1975-07-01

    An analysis is developed to determine safe headway on PRT systems that use point-follower control. Periodic measurements of the position error relative to a nominal trajectory provide warning against the hazards of overspeed and unexpected stop. A co...

  11. Parametric Modulation of Error-Related ERP Components by the Magnitude of Visuo-Motor Mismatch

    ERIC Educational Resources Information Center

    Vocat, Roland; Pourtois, Gilles; Vuilleumier, Patrik

    2011-01-01

    Errors generate typical brain responses, characterized by two successive event-related potentials (ERP) following incorrect action: the error-related negativity (ERN) and the positivity error (Pe). However, it is unclear whether these error-related responses are sensitive to the magnitude of the error, or instead show all-or-none effects. We…

  12. Volumetric error modeling, identification and compensation based on screw theory for a large multi-axis propeller-measuring machine

    NASA Astrophysics Data System (ADS)

    Zhong, Xuemin; Liu, Hongqi; Mao, Xinyong; Li, Bin; He, Songping; Peng, Fangyu

    2018-05-01

    Large multi-axis propeller-measuring machines have two types of geometric error, position-independent geometric errors (PIGEs) and position-dependent geometric errors (PDGEs), which both have significant effects on the volumetric error of the measuring tool relative to the worktable. This paper focuses on modeling, identifying and compensating for the volumetric error of the measuring machine. A volumetric error model in the base coordinate system is established based on screw theory considering all the geometric errors. In order to fully identify all the geometric error parameters, a new method for systematic measurement and identification is proposed. All the PIGEs of adjacent axes and the six PDGEs of the linear axes are identified with a laser tracker using the proposed model. Finally, a volumetric error compensation strategy is presented and an inverse kinematic solution for compensation is proposed. The final measuring and compensation experiments have further verified the efficiency and effectiveness of the measuring and identification method, indicating that the method can be used in volumetric error compensation for large machine tools.

  13. [Transposition errors during learning to reproduce a sequence by the right- and the left-hand movements: simulation of positional and movement coding].

    PubMed

    Liakhovetskiĭ, V A; Bobrova, E V; Skopin, G N

    2012-01-01

    Transposition errors during the reproduction of a hand movement sequence make it possible to receive important information on the internal representation of this sequence in the motor working memory. Analysis of such errors showed that learning to reproduce sequences of the left-hand movements improves the system of positional coding (coding ofpositions), while learning of the right-hand movements improves the system of vector coding (coding of movements). Learning of the right-hand movements after the left-hand performance involved the system of positional coding "imposed" by the left hand. Learning of the left-hand movements after the right-hand performance activated the system of vector coding. Transposition errors during learning to reproduce movement sequences can be explained by neural network using either vector coding or both vector and positional coding.

  14. Source localization (LORETA) of the error-related-negativity (ERN/Ne) and positivity (Pe).

    PubMed

    Herrmann, Martin J; Römmler, Josefine; Ehlis, Ann-Christine; Heidrich, Anke; Fallgatter, Andreas J

    2004-07-01

    We investigated error processing of 39 subjects engaging the Eriksen flanker task. In all 39 subjects a pronounced negative deflection (ERN/Ne) and a later positive component (Pe) were observed after incorrect as compared to correct responses. The neural sources of both components were analyzed using LORETA source localization. For the negative component (ERN/Ne) we found significantly higher brain electrical activity in medial prefrontal areas for incorrect responses, whereas the positive component (Pe) was localized nearby but more rostral within the anterior cingulate cortex (ACC). Thus, different neural generators were found for the ERN/Ne and the Pe, which further supports the notion that both error-related components represent different aspects of error processing.

  15. Mitigating Errors in External Respiratory Surrogate-Based Models of Tumor Position

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malinowski, Kathleen T.; Fischell Department of Bioengineering, University of Maryland, College Park, MD; McAvoy, Thomas J.

    2012-04-01

    Purpose: To investigate the effect of tumor site, measurement precision, tumor-surrogate correlation, training data selection, model design, and interpatient and interfraction variations on the accuracy of external marker-based models of tumor position. Methods and Materials: Cyberknife Synchrony system log files comprising synchronously acquired positions of external markers and the tumor from 167 treatment fractions were analyzed. The accuracy of Synchrony, ordinary-least-squares regression, and partial-least-squares regression models for predicting the tumor position from the external markers was evaluated. The quantity and timing of the data used to build the predictive model were varied. The effects of tumor-surrogate correlation and the precisionmore » in both the tumor and the external surrogate position measurements were explored by adding noise to the data. Results: The tumor position prediction errors increased during the duration of a fraction. Increasing the training data quantities did not always lead to more accurate models. Adding uncorrelated noise to the external marker-based inputs degraded the tumor-surrogate correlation models by 16% for partial-least-squares and 57% for ordinary-least-squares. External marker and tumor position measurement errors led to tumor position prediction changes 0.3-3.6 times the magnitude of the measurement errors, varying widely with model algorithm. The tumor position prediction errors were significantly associated with the patient index but not with the fraction index or tumor site. Partial-least-squares was as accurate as Synchrony and more accurate than ordinary-least-squares. Conclusions: The accuracy of surrogate-based inferential models of tumor position was affected by all the investigated factors, except for the tumor site and fraction index.« less

  16. The propagation of inventory-based positional errors into statistical landslide susceptibility models

    NASA Astrophysics Data System (ADS)

    Steger, Stefan; Brenning, Alexander; Bell, Rainer; Glade, Thomas

    2016-12-01

    There is unanimous agreement that a precise spatial representation of past landslide occurrences is a prerequisite to produce high quality statistical landslide susceptibility models. Even though perfectly accurate landslide inventories rarely exist, investigations of how landslide inventory-based errors propagate into subsequent statistical landslide susceptibility models are scarce. The main objective of this research was to systematically examine whether and how inventory-based positional inaccuracies of different magnitudes influence modelled relationships, validation results, variable importance and the visual appearance of landslide susceptibility maps. The study was conducted for a landslide-prone site located in the districts of Amstetten and Waidhofen an der Ybbs, eastern Austria, where an earth-slide point inventory was available. The methodological approach comprised an artificial introduction of inventory-based positional errors into the present landslide data set and an in-depth evaluation of subsequent modelling results. Positional errors were introduced by artificially changing the original landslide position by a mean distance of 5, 10, 20, 50 and 120 m. The resulting differently precise response variables were separately used to train logistic regression models. Odds ratios of predictor variables provided insights into modelled relationships. Cross-validation and spatial cross-validation enabled an assessment of predictive performances and permutation-based variable importance. All analyses were additionally carried out with synthetically generated data sets to further verify the findings under rather controlled conditions. The results revealed that an increasing positional inventory-based error was generally related to increasing distortions of modelling and validation results. However, the findings also highlighted that interdependencies between inventory-based spatial inaccuracies and statistical landslide susceptibility models are complex. The systematic comparisons of 12 models provided valuable evidence that the respective error-propagation was not only determined by the degree of positional inaccuracy inherent in the landslide data, but also by the spatial representation of landslides and the environment, landslide magnitude, the characteristics of the study area, the selected classification method and an interplay of predictors within multiple variable models. Based on the results, we deduced that a direct propagation of minor to moderate inventory-based positional errors into modelling results can be partly counteracted by adapting the modelling design (e.g. generalization of input data, opting for strongly generalizing classifiers). Since positional errors within landslide inventories are common and subsequent modelling and validation results are likely to be distorted, the potential existence of inventory-based positional inaccuracies should always be considered when assessing landslide susceptibility by means of empirical models.

  17. Positional reference system for ultraprecision machining

    DOEpatents

    Arnold, Jones B.; Burleson, Robert R.; Pardue, Robert M.

    1982-01-01

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  18. Positional reference system for ultraprecision machining

    DOEpatents

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1980-09-12

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  19. [A Quality Assurance (QA) System with a Web Camera for High-dose-rate Brachytherapy].

    PubMed

    Hirose, Asako; Ueda, Yoshihiro; Oohira, Shingo; Isono, Masaru; Tsujii, Katsutomo; Inui, Shouki; Masaoka, Akira; Taniguchi, Makoto; Miyazaki, Masayoshi; Teshima, Teruki

    2016-03-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an (192)Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.31±0.1 mm and that of dwell time errors 0.1±0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xing, Y; Macq, B; Bondar, L

    Purpose: To quantify the accuracy in predicting the Bragg peak position using simulated in-room measurements of prompt gamma (PG) emissions for realistic treatment error scenarios that combine several sources of errors. Methods: Prompt gamma measurements by a knife-edge slit camera were simulated using an experimentally validated analytical simulation tool. Simulations were performed, for 143 treatment error scenarios, on an anthropomorphic phantom and a pencil beam scanning plan for nasal cavity. Three types of errors were considered: translation along each axis, rotation around each axis, and CT-calibration errors with magnitude ranging respectively, between −3 and 3 mm, −5 and 5 degrees,more » and between −5 and +5%. We investigated the correlation between the Bragg peak (BP) shift and the horizontal shift of PG profiles. The shifts were calculated between the planned (reference) position and the position by the error scenario. The prediction error for one spot was calculated as the absolute difference between the PG profile shift and the BP shift. Results: The PG shift was significantly and strongly correlated with the BP shift for 92% of the cases (p<0.0001, Pearson correlation coefficient R>0.8). Moderate but significant correlations were obtained for all cases that considered only CT-calibration errors and for 1 case that combined translation and CT-errors (p<0.0001, R ranged between 0.61 and 0.8). The average prediction errors for the simulated scenarios ranged between 0.08±0.07 and 1.67±1.3 mm (grand mean 0.66±0.76 mm). The prediction error was moderately correlated with the value of the BP shift (p=0, R=0.64). For the simulated scenarios the average BP shift ranged between −8±6.5 mm and 3±1.1 mm. Scenarios that considered combinations of the largest treatment errors were associated with large BP shifts. Conclusion: Simulations of in-room measurements demonstrate that prompt gamma profiles provide reliable estimation of the Bragg peak position for complex error scenarios. Yafei Xing and Luiza Bondar are funded by BEWARE grants from the Walloon Region. The work presents simulations results for a prompt gamma camera prototype developed by IBA.« less

  1. How personal standards perfectionism and evaluative concerns perfectionism affect the error positivity and post-error behavior with varying stimulus visibility.

    PubMed

    Drizinsky, Jessica; Zülch, Joachim; Gibbons, Henning; Stahl, Jutta

    2016-10-01

    Error detection is required in order to correct or avoid imperfect behavior. Although error detection is beneficial for some people, for others it might be disturbing. We investigated Gaudreau and Thompson's (Personality and Individual Differences, 48, 532-537, 2010) model, which combines personal standards perfectionism (PSP) and evaluative concerns perfectionism (ECP). In our electrophysiological study, 43 participants performed a combination of a modified Simon task, an error awareness paradigm, and a masking task with a variation of stimulus onset asynchrony (SOA; 33, 67, and 100 ms). Interestingly, relative to low-ECP participants, high-ECP participants showed a better post-error accuracy (despite a worse classification accuracy) in the high-visibility SOA 100 condition than in the two low-visibility conditions (SOA 33 and SOA 67). Regarding the electrophysiological results, first, we found a positive correlation between ECP and the amplitude of the error positivity (Pe) under conditions of low stimulus visibility. Second, under the condition of high stimulus visibility, we observed a higher Pe amplitude for high-ECP-low-PSP participants than for high-ECP-high-PSP participants. These findings are discussed within the framework of the error-processing avoidance hypothesis of perfectionism (Stahl, Acharki, Kresimon, Völler, & Gibbons, International Journal of Psychophysiology, 97, 153-162, 2015).

  2. Accuracy assessment of high-rate GPS measurements for seismology

    NASA Astrophysics Data System (ADS)

    Elosegui, P.; Davis, J. L.; Ekström, G.

    2007-12-01

    Analysis of GPS measurements with a controlled laboratory system, built to simulate the ground motions caused by tectonic earthquakes and other transient geophysical signals such as glacial earthquakes, enables us to assess the technique of high-rate GPS. The root-mean-square (rms) position error of this system when undergoing realistic simulated seismic motions is 0.05~mm, with maximum position errors of 0.1~mm, thus providing "ground truth" GPS displacements. We have acquired an extensive set of high-rate GPS measurements while inducing seismic motions on a GPS antenna mounted on this system with a temporal spectrum similar to real seismic events. We found that, for a particular 15-min-long test event, the rms error of the 1-Hz GPS position estimates was 2.5~mm, with maximum position errors of 10~mm, and the error spectrum of the GPS estimates was approximately flicker noise. These results may however represent a best-case scenario since they were obtained over a short (~10~m) baseline, thereby greatly mitigating baseline-dependent errors, and when the number and distribution of satellites on the sky was good. For example, we have determined that the rms error can increase by a factor of 2--3 as the GPS constellation changes throughout the day, with an average value of 3.5~mm for eight identical, hourly-spaced, consecutive test events. The rms error also increases with increasing baseline, as one would expect, with an average rms error for a ~1400~km baseline of 9~mm. We will present an assessment of the accuracy of high-rate GPS based on these measurements, discuss the implications of this study for seismology, and describe new applications in glaciology.

  3. Cervicocephalic kinesthetic sensibility in young and middle-aged adults with or without a history of mild neck pain.

    PubMed

    Teng, C-C; Chai, H; Lai, D-M; Wang, S-F

    2007-02-01

    Previous research has shown that there is no significant relationship between the degree of structural degeneration of the cervical spine and neck pain. We therefore sought to investigate the potential role of sensory dysfunction in chronic neck pain. Cervicocephalic kinesthetic sensibility, expressed by how accurately an individual can reposition the head, was studied in three groups of individuals, a control group of 20 asymptomatic young adults and two groups of middle-aged adults (20 subjects in each group) with or without a history of mild neck pain. An ultrasound-based three-dimensional coordinate measuring system was used to measure the position of the head and to test the accuracy of repositioning. Constant error (indicating that the subject overshot or undershot the intended position) and root mean square errors (representing total errors of accuracy and variability) were measured during repositioning of the head to the neutral head position (Head-to-NHP) and repositioning of the head to the target (Head-to-Target) in three cardinal planes (sagittal, transverse, and frontal). Analysis of covariance (ANCOVA) was used to test the group effect, with age used as a covariate. The constant errors during repositioning from a flexed position and from an extended position to the NHP were significantly greater in the middle-aged subjects than in the control group (beta=0.30 and beta=0.60, respectively; P<0.05 for both). In addition, the root mean square errors during repositioning from a flexed or extended position to the NHP were greater in the middle-aged subjects than in the control group (beta=0.27 and beta=0.49, respectively; P<0.05 for both). The root mean square errors also increased during Head-to-Target in left rotation (beta=0.24;P<0.05), but there was no difference in the constant errors or root mean square errors during Head-to-NHP repositioning from other target positions (P>0.05). The results indicate that, after controlling for age as a covariate, there was no group effect. Thus, age appears to have a profound effect on an individual's ability to accurately reposition the head toward the neutral position in the sagittal plane and repositioning the head toward left rotation. A history of mild chronic neck pain alone had no significant effect on cervicocephalic kinesthetic sensibility.

  4. A case study of the New York City 2012-2013 influenza season with daily geocoded Twitter data from temporal and spatiotemporal perspectives.

    PubMed

    Nagar, Ruchit; Yuan, Qingyu; Freifeld, Clark C; Santillana, Mauricio; Nojima, Aaron; Chunara, Rumi; Brownstein, John S

    2014-10-20

    Twitter has shown some usefulness in predicting influenza cases on a weekly basis in multiple countries and on different geographic scales. Recently, Broniatowski and colleagues suggested Twitter's relevance at the city-level for New York City. Here, we look to dive deeper into the case of New York City by analyzing daily Twitter data from temporal and spatiotemporal perspectives. Also, through manual coding of all tweets, we look to gain qualitative insights that can help direct future automated searches. The intent of the study was first to validate the temporal predictive strength of daily Twitter data for influenza-like illness emergency department (ILI-ED) visits during the New York City 2012-2013 influenza season against other available and established datasets (Google search query, or GSQ), and second, to examine the spatial distribution and the spread of geocoded tweets as proxies for potential cases. From the Twitter Streaming API, 2972 tweets were collected in the New York City region matching the keywords "flu", "influenza", "gripe", and "high fever". The tweets were categorized according to the scheme developed by Lamb et al. A new fourth category was added as an evaluator guess for the probability of the subject(s) being sick to account for strength of confidence in the validity of the statement. Temporal correlations were made for tweets against daily ILI-ED visits and daily GSQ volume. The best models were used for linear regression for forecasting ILI visits. A weighted, retrospective Poisson model with SaTScan software (n=1484), and vector map were used for spatiotemporal analysis. Infection-related tweets (R=.763) correlated better than GSQ time series (R=.683) for the same keywords and had a lower mean average percent error (8.4 vs 11.8) for ILI-ED visit prediction in January, the most volatile month of flu. SaTScan identified primary outbreak cluster of high-probability infection tweets with a 2.74 relative risk ratio compared to medium-probability infection tweets at P=.001 in Northern Brooklyn, in a radius that includes Barclay's Center and the Atlantic Avenue Terminal. While others have looked at weekly regional tweets, this study is the first to stress test Twitter for daily city-level data for New York City. Extraction of personal testimonies of infection-related tweets suggests Twitter's strength both qualitatively and quantitatively for ILI-ED prediction compared to alternative daily datasets mixed with awareness-based data such as GSQ. Additionally, granular Twitter data provide important spatiotemporal insights. A tweet vector-map may be useful for visualization of city-level spread when local gold standard data are otherwise unavailable.

  5. A Case Study of the New York City 2012-2013 Influenza Season With Daily Geocoded Twitter Data From Temporal and Spatiotemporal Perspectives

    PubMed Central

    Yuan, Qingyu; Freifeld, Clark C; Santillana, Mauricio; Nojima, Aaron; Chunara, Rumi; Brownstein, John S

    2014-01-01

    Background Twitter has shown some usefulness in predicting influenza cases on a weekly basis in multiple countries and on different geographic scales. Recently, Broniatowski and colleagues suggested Twitter’s relevance at the city-level for New York City. Here, we look to dive deeper into the case of New York City by analyzing daily Twitter data from temporal and spatiotemporal perspectives. Also, through manual coding of all tweets, we look to gain qualitative insights that can help direct future automated searches. Objective The intent of the study was first to validate the temporal predictive strength of daily Twitter data for influenza-like illness emergency department (ILI-ED) visits during the New York City 2012-2013 influenza season against other available and established datasets (Google search query, or GSQ), and second, to examine the spatial distribution and the spread of geocoded tweets as proxies for potential cases. Methods From the Twitter Streaming API, 2972 tweets were collected in the New York City region matching the keywords “flu”, “influenza”, “gripe”, and “high fever”. The tweets were categorized according to the scheme developed by Lamb et al. A new fourth category was added as an evaluator guess for the probability of the subject(s) being sick to account for strength of confidence in the validity of the statement. Temporal correlations were made for tweets against daily ILI-ED visits and daily GSQ volume. The best models were used for linear regression for forecasting ILI visits. A weighted, retrospective Poisson model with SaTScan software (n=1484), and vector map were used for spatiotemporal analysis. Results Infection-related tweets (R=.763) correlated better than GSQ time series (R=.683) for the same keywords and had a lower mean average percent error (8.4 vs 11.8) for ILI-ED visit prediction in January, the most volatile month of flu. SaTScan identified primary outbreak cluster of high-probability infection tweets with a 2.74 relative risk ratio compared to medium-probability infection tweets at P=.001 in Northern Brooklyn, in a radius that includes Barclay’s Center and the Atlantic Avenue Terminal. Conclusions While others have looked at weekly regional tweets, this study is the first to stress test Twitter for daily city-level data for New York City. Extraction of personal testimonies of infection-related tweets suggests Twitter’s strength both qualitatively and quantitatively for ILI-ED prediction compared to alternative daily datasets mixed with awareness-based data such as GSQ. Additionally, granular Twitter data provide important spatiotemporal insights. A tweet vector-map may be useful for visualization of city-level spread when local gold standard data are otherwise unavailable. PMID:25331122

  6. Force reflection with compliance control

    NASA Technical Reports Server (NTRS)

    Kim, Won S. (Inventor)

    1993-01-01

    Two types of systems for force-reflecting control, which enables high force-reflection gain, are presented: position-error-based force reflection and low-pass-filtered force reflection. Both of the systems are combined with shared compliance control. In the position-error-based class, the position error between the commanded and the actual position of a compliantly controlled robot is used to provide force reflection. In the low-pass-filtered force reflection class, the low-pass-filtered output of the compliance control is used to provide force reflection. The increase in force reflection gain can be more than 10-fold as compared to a conventional high-bandwidth pure force reflection system, when high compliance values are used for the compliance control.

  7. Acetaminophen attenuates error evaluation in cortex

    PubMed Central

    Kam, Julia W.Y.; Heine, Steven J.; Inzlicht, Michael; Handy, Todd C.

    2016-01-01

    Acetaminophen has recently been recognized as having impacts that extend into the affective domain. In particular, double blind placebo controlled trials have revealed that acetaminophen reduces the magnitude of reactivity to social rejection, frustration, dissonance and to both negatively and positively valenced attitude objects. Given this diversity of consequences, it has been proposed that the psychological effects of acetaminophen may reflect a widespread blunting of evaluative processing. We tested this hypothesis using event-related potentials (ERPs). Sixty-two participants received acetaminophen or a placebo in a double-blind protocol and completed the Go/NoGo task. Participants’ ERPs were observed following errors on the Go/NoGo task, in particular the error-related negativity (ERN; measured at FCz) and error-related positivity (Pe; measured at Pz and CPz). Results show that acetaminophen inhibits the Pe, but not the ERN, and the magnitude of an individual’s Pe correlates positively with omission errors, partially mediating the effects of acetaminophen on the error rate. These results suggest that recently documented affective blunting caused by acetaminophen may best be described as an inhibition of evaluative processing. They also contribute to the growing work suggesting that the Pe is more strongly associated with conscious awareness of errors relative to the ERN. PMID:26892161

  8. Adaptation of catch-up saccades during the initiation of smooth pursuit eye movements.

    PubMed

    Schütz, Alexander C; Souto, David

    2011-04-01

    Reduction of retinal speed and alignment of the line of sight are believed to be the respective primary functions of smooth pursuit and saccadic eye movements. As the eye muscles strength can change in the short-term, continuous adjustments of motor signals are required to achieve constant accuracy. While adaptation of saccade amplitude to systematic position errors has been extensively studied, we know less about the adaptive response to position errors during smooth pursuit initiation, when target motion has to be taken into account to program saccades, and when position errors at the saccade endpoint could also be corrected by increasing pursuit velocity. To study short-term adaptation (250 adaptation trials) of tracking eye movements, we introduced a position error during the first catch-up saccade made during the initiation of smooth pursuit-in a ramp-step-ramp paradigm. The target position was either shifted in the direction of the horizontally moving target (forward step), against it (backward step) or orthogonally to it (vertical step). Results indicate adaptation of catch-up saccade amplitude to back and forward steps. With vertical steps, saccades became oblique, by an inflexion of the early or late saccade trajectory. With a similar time course, post-saccadic pursuit velocity was increased in the step direction, adding further evidence that under some conditions pursuit and saccades can act synergistically to reduce position errors.

  9. Air data position-error calibration using state reconstruction techniques

    NASA Technical Reports Server (NTRS)

    Whitmore, S. A.; Larson, T. J.; Ehernberger, L. J.

    1984-01-01

    During the highly maneuverable aircraft technology (HiMAT) flight test program recently completed at NASA Ames Research Center's Dryden Flight Research Facility, numerous problems were experienced in airspeed calibration. This necessitated the use of state reconstruction techniques to arrive at a position-error calibration. For the HiMAT aircraft, most of the calibration effort was expended on flights in which the air data pressure transducers were not performing accurately. Following discovery of this problem, the air data transducers of both aircraft were wrapped in heater blankets to correct the problem. Additional calibration flights were performed, and from the resulting data a satisfactory position-error calibration was obtained. This calibration and data obtained before installation of the heater blankets were used to develop an alternate calibration method. The alternate approach took advantage of high-quality inertial data that was readily available. A linearized Kalman filter (LKF) was used to reconstruct the aircraft's wind-relative trajectory; the trajectory was then used to separate transducer measurement errors from the aircraft position error. This calibration method is accurate and inexpensive. The LKF technique has an inherent advantage of requiring that no flight maneuvers be specially designed for airspeed calibrations. It is of particular use when the measurements of the wind-relative quantities are suspected to have transducer-related errors.

  10. Is adult gait less susceptible than paediatric gait to hip joint centre regression equation error?

    PubMed

    Kiernan, D; Hosking, J; O'Brien, T

    2016-03-01

    Hip joint centre (HJC) regression equation error during paediatric gait has recently been shown to have clinical significance. In relation to adult gait, it has been inferred that comparable errors with children in absolute HJC position may in fact result in less significant kinematic and kinetic error. This study investigated the clinical agreement of three commonly used regression equation sets (Bell et al., Davis et al. and Orthotrak) for adult subjects against the equations of Harrington et al. The relationship between HJC position error and subject size was also investigated for the Davis et al. set. Full 3-dimensional gait analysis was performed on 12 healthy adult subjects with data for each set compared to Harrington et al. The Gait Profile Score, Gait Variable Score and GDI-kinetic were used to assess clinical significance while differences in HJC position between the Davis and Harrington sets were compared to leg length and subject height using regression analysis. A number of statistically significant differences were present in absolute HJC position. However, all sets fell below the clinically significant thresholds (GPS <1.6°, GDI-Kinetic <3.6 points). Linear regression revealed a statistically significant relationship for both increasing leg length and increasing subject height with decreasing error in anterior/posterior and superior/inferior directions. Results confirm a negligible clinical error for adult subjects suggesting that any of the examined sets could be used interchangeably. Decreasing error with both increasing leg length and increasing subject height suggests that the Davis set should be used cautiously on smaller subjects. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Is Comprehension Necessary for Error Detection? A Conflict-Based Account of Monitoring in Speech Production

    ERIC Educational Resources Information Center

    Nozari, Nazbanou; Dell, Gary S.; Schwartz, Myrna F.

    2011-01-01

    Despite the existence of speech errors, verbal communication is successful because speakers can detect (and correct) their errors. The standard theory of speech-error detection, the perceptual-loop account, posits that the comprehension system monitors production output for errors. Such a comprehension-based monitor, however, cannot explain the…

  12. Error-Related Psychophysiology and Negative Affect

    ERIC Educational Resources Information Center

    Hajcak, G.; McDonald, N.; Simons, R.F.

    2004-01-01

    The error-related negativity (ERN/Ne) and error positivity (Pe) have been associated with error detection and response monitoring. More recently, heart rate (HR) and skin conductance (SC) have also been shown to be sensitive to the internal detection of errors. An enhanced ERN has consistently been observed in anxious subjects and there is some…

  13. Circular Array of Magnetic Sensors for Current Measurement: Analysis for Error Caused by Position of Conductor.

    PubMed

    Yu, Hao; Qian, Zheng; Liu, Huayi; Qu, Jiaqi

    2018-02-14

    This paper analyzes the measurement error, caused by the position of the current-carrying conductor, of a circular array of magnetic sensors for current measurement. The circular array of magnetic sensors is an effective approach for AC or DC non-contact measurement, as it is low-cost, light-weight, has a large linear range, wide bandwidth, and low noise. Especially, it has been claimed that such structure has excellent reduction ability for errors caused by the position of the current-carrying conductor, crosstalk current interference, shape of the conduction cross-section, and the Earth's magnetic field. However, the positions of the current-carrying conductor-including un-centeredness and un-perpendicularity-have not been analyzed in detail until now. In this paper, for the purpose of having minimum measurement error, a theoretical analysis has been proposed based on vector inner and exterior product. In the presented mathematical model of relative error, the un-center offset distance, the un-perpendicular angle, the radius of the circle, and the number of magnetic sensors are expressed in one equation. The comparison of the relative error caused by the position of the current-carrying conductor between four and eight sensors is conducted. Tunnel magnetoresistance (TMR) sensors are used in the experimental prototype to verify the mathematical model. The analysis results can be the reference to design the details of the circular array of magnetic sensors for current measurement in practical situations.

  14. Evaluation of exome variants using the Ion Proton Platform to sequence error-prone regions.

    PubMed

    Seo, Heewon; Park, Yoomi; Min, Byung Joo; Seo, Myung Eui; Kim, Ju Han

    2017-01-01

    The Ion Proton sequencer from Thermo Fisher accurately determines sequence variants from target regions with a rapid turnaround time at a low cost. However, misleading variant-calling errors can occur. We performed a systematic evaluation and manual curation of read-level alignments for the 675 ultrarare variants reported by the Ion Proton sequencer from 27 whole-exome sequencing data but that are not present in either the 1000 Genomes Project and the Exome Aggregation Consortium. We classified positive variant calls into 393 highly likely false positives, 126 likely false positives, and 156 likely true positives, which comprised 58.2%, 18.7%, and 23.1% of the variants, respectively. We identified four distinct error patterns of variant calling that may be bioinformatically corrected when using different strategies: simplicity region, SNV cluster, peripheral sequence read, and base inversion. Local de novo assembly successfully corrected 201 (38.7%) of the 519 highly likely or likely false positives. We also demonstrate that the two sequencing kits from Thermo Fisher (the Ion PI Sequencing 200 kit V3 and the Ion PI Hi-Q kit) exhibit different error profiles across different error types. A refined calling algorithm with better polymerase may improve the performance of the Ion Proton sequencing platform.

  15. Estimate of higher order ionospheric errors in GNSS positioning

    NASA Astrophysics Data System (ADS)

    Hoque, M. Mainul; Jakowski, N.

    2008-10-01

    Precise navigation and positioning using GPS/GLONASS/Galileo require the ionospheric propagation errors to be accurately determined and corrected for. Current dual-frequency method of ionospheric correction ignores higher order ionospheric errors such as the second and third order ionospheric terms in the refractive index formula and errors due to bending of the signal. The total electron content (TEC) is assumed to be same at two GPS frequencies. All these assumptions lead to erroneous estimations and corrections of the ionospheric errors. In this paper a rigorous treatment of these problems is presented. Different approximation formulas have been proposed to correct errors due to excess path length in addition to the free space path length, TEC difference at two GNSS frequencies, and third-order ionospheric term. The GPS dual-frequency residual range errors can be corrected within millimeter level accuracy using the proposed correction formulas.

  16. Modeling of Geometric Error in Linear Guide Way to Improved the vertical three-axis CNC Milling machine’s accuracy

    NASA Astrophysics Data System (ADS)

    Kwintarini, Widiyanti; Wibowo, Agung; Arthaya, Bagus M.; Yuwana Martawirya, Yatna

    2018-03-01

    The purpose of this study was to improve the accuracy of three-axis CNC Milling Vertical engines with a general approach by using mathematical modeling methods of machine tool geometric errors. The inaccuracy of CNC machines can be caused by geometric errors that are an important factor during the manufacturing process and during the assembly phase, and are factors for being able to build machines with high-accuracy. To improve the accuracy of the three-axis vertical milling machine, by knowing geometric errors and identifying the error position parameters in the machine tool by arranging the mathematical modeling. The geometric error in the machine tool consists of twenty-one error parameters consisting of nine linear error parameters, nine angle error parameters and three perpendicular error parameters. The mathematical modeling approach of geometric error with the calculated alignment error and angle error in the supporting components of the machine motion is linear guide way and linear motion. The purpose of using this mathematical modeling approach is the identification of geometric errors that can be helpful as reference during the design, assembly and maintenance stages to improve the accuracy of CNC machines. Mathematically modeling geometric errors in CNC machine tools can illustrate the relationship between alignment error, position and angle on a linear guide way of three-axis vertical milling machines.

  17. Making Mosaics Of SAR Imagery

    NASA Technical Reports Server (NTRS)

    Curlander, John C.; Kwok, Ronald; Pang, Shirley S.; Pang, Amy A.

    1990-01-01

    Spaceborne synthetic-aperture-radar (SAR) images useful for mapping of planets and investigations in Earth sciences. Produces multiframe mosaic by combining images along ground track, in adjacent cross-track swaths, or in ascending and descending passes. Images registered with geocoded maps such as ones produced by MAPJTC (NPO-17718), required as input. Minimal intervention by operator required. MOSK implemented on DEC VAX 11/785 computer running VMS 4.5. Most subroutines in FORTRAN, but three in MAXL and one in APAL.

  18. Assessment of Geographic Information Systems and Data Confidentiality Guidelines in STD Programs.

    PubMed

    Bissette, Jennifer M; Stover, Jeffrey A; Newman, Lori M; Delcher, Philip Christopher; Bernstein, Kyle T; Matthews, Lindsey

    2009-01-01

    Advancements in technology, such as geographic information systems (GIS), expand sexually transmitted disease (STD) program capacity for data analysis and visualization, and introduce additional confidentiality considerations. We developed a survey to examine GIS use among STD programs and to better understand existing data confidentiality practices. A Web-based survey of eight to 22 questions, depending on program-specific GIS capacity, was e-mailed to all STD program directors through the National Coalition of STD Directors in November 2004. Survey responses were accepted until April 15, 2005. Eighty-five percent of the 65 currently funded STD programs responded to the survey. Of those, 58% used GIS and 54% used geocoding. STD programs that did not use GIS (42%) identified lack of training and insufficient staff as primary barriers. Mapping, spatial analyses, and targeting program interventions were the main reasons for geocoding data. Nineteen of the 25 programs that responded to questions related to statistical disclosure rules employed a numerator rule, and 56% of those used a variation of the "Rule of 5." Of the 28 programs that responded to questions pertaining to confidentiality guidelines, 82% addressed confidentiality of GIS data informally. Survey findings showed the increasing use of GIS and highlighted the struggles STD programs face in employing GIS and protecting confidentiality. Guidance related to data confidentiality and additional access to GIS software and training could assist programs in optimizing use of spatial data.

  19. Measuring health-relevant businesses over 21 years: refining the National Establishment Time-Series (NETS), a dynamic longitudinal data set.

    PubMed

    Kaufman, Tanya K; Sheehan, Daniel M; Rundle, Andrew; Neckerman, Kathryn M; Bader, Michael D M; Jack, Darby; Lovasi, Gina S

    2015-09-29

    The densities of food retailers, alcohol outlets, physical activity facilities, and medical facilities have been associated with diet, physical activity, and management of medical conditions. Most of the research, however, has relied on cross-sectional studies. In this paper, we assess methodological issues raised by a data source that is increasingly used to characterize change in the local business environment: the National Establishment Time Series (NETS) dataset. Longitudinal data, such as NETS, offer opportunities to assess how differential access to resources impacts population health, to consider correlations among multiple environmental influences across the life course, and to gain a better understanding of their interactions and cumulative health effects. Longitudinal data also introduce new data management, geoprocessing, and business categorization challenges. Examining geocoding accuracy and categorization over 21 years of data in 23 counties surrounding New York City (NY, USA), we find that health-related business environments change considerably over time. We note that re-geocoding data may improve spatial precision, particularly in early years. Our intent with this paper is to make future public health applications of NETS data more efficient, since the size and complexity of the data can be difficult to exploit fully within its 2-year data-licensing period. Further, standardized approaches to NETS and other "big data" will facilitate the veracity and comparability of results across studies.

  20. Farmer data sourcing. The case study of the spatial soil information maps in South Tyrol.

    NASA Astrophysics Data System (ADS)

    Della Chiesa, Stefano; Niedrist, Georg; Thalheimer, Martin; Hafner, Hansjörg; La Cecilia, Daniele

    2017-04-01

    Nord-Italian region South Tyrol is Europe's largest apple growing area exporting ca. 15% in Europe and 2% worldwide. Vineyards represent ca. 1% of Italian production. In order to deliver high quality food, most of the farmers in South Tyrol follow sustainable farming practices. One of the key practice is the sustainable soil management, where farmers collect regularly (each 5 years) soil samples and send for analyses to improve cultivation management, yield and finally profitability. However, such data generally remain inaccessible. On this regard, in South Tyrol, private interests and the public administration have established a long tradition of collaboration with the local farming industry. This has granted to the collection of large spatial and temporal database of soil analyses along all the cultivated areas. Thanks to this best practice, information on soil properties are centralized and geocoded. The large dataset consist mainly in soil information of texture, humus content, pH and microelements availability such as, K, Mg, Bor, Mn, Cu Zn. This data was finally spatialized by mean of geostatistical methods and several high-resolution digital maps were created. In this contribution, we present the best practice where farmers data source soil information in South Tyrol. Show the capability of a large spatial-temporal geocoded soil dataset to reproduce detailed digital soil property maps and to assess long-term changes in soil properties. Finally, implication and potential application are discussed.

  1. Drought - A Global Assessment

    NASA Astrophysics Data System (ADS)

    Lackner, S.; Barnwal, P.; von der Goltz, J.

    2013-12-01

    We investigate the lasting effects of early childhood exposure to drought on economic and health outcomes in a large multi-country dataset. By pooling all Demographic and Health Survey rounds for which household geocodes are available, we obtain an individual-level dataset covering 47 developing countries. Among other impact measures, we collect infant and child mortality data from 3.3m live births and data on stunting and wasting for 1.2m individuals, along with data on education, employment, wealth, marriage and childbearing later in life for similarly large numbers of respondents. Birth years vary from 1893 to 2012. We seek to improve upon existing work on the socio-economic impact of drought in a number of ways. First, we introduce from the hydrological literature a drought measure, the Standardized Precipitation Index (SPI), that has been shown to closely proxy the Palmer drought index, but has far less demanding data requirements, and can be obtained globally and for long time periods. We estimate the SPI for 110 years on a global 0.5° grid, which allows us to assign drought histories to the geocoded individual data. Additionally, we leverage our large sample size to explicitly investigate both how drought impacts have changed over time as adaptation occurred at a varying pace in different locations, and the role of the regional extent of drought in determining impacts.

  2. Web-based GIS for spatial pattern detection: application to malaria incidence in Vietnam.

    PubMed

    Bui, Thanh Quang; Pham, Hai Minh

    2016-01-01

    There is a great concern on how to build up an interoperable health information system of public health and health information technology within the development of public information and health surveillance programme. Technically, some major issues remain regarding to health data visualization, spatial processing of health data, health information dissemination, data sharing and the access of local communities to health information. In combination with GIS, we propose a technical framework for web-based health data visualization and spatial analysis. Data was collected from open map-servers and geocoded by open data kit package and data geocoding tools. The Web-based system is designed based on Open-source frameworks and libraries. The system provides Web-based analyst tool for pattern detection through three spatial tests: Nearest neighbour, K function, and Spatial Autocorrelation. The result is a web-based GIS, through which end users can detect disease patterns via selecting area, spatial test parameters and contribute to managers and decision makers. The end users can be health practitioners, educators, local communities, health sector authorities and decision makers. This web-based system allows for the improvement of health related services to public sector users as well as citizens in a secure manner. The combination of spatial statistics and web-based GIS can be a solution that helps empower health practitioners in direct and specific intersectional actions, thus provide for better analysis, control and decision-making.

  3. Supporting creativity and appreciation of uncertainty in exploring geo-coded public health data.

    PubMed

    Thew, S L; Sutcliffe, A; de Bruijn, O; McNaught, J; Procter, R; Jarvis, Paul; Buchan, I

    2011-01-01

    We present a prototype visualisation tool, ADVISES (Adaptive Visualization for e-Science), designed to support epidemiologists and public health practitioners in exploring geo-coded datasets and generating spatial epidemiological hypotheses. The tool is designed to support creative thinking while providing the means for the user to evaluate the validity of the visualization in terms of statistical uncertainty. We present an overview of the application and the results of an evaluation exploring public health researchers' responses to maps as a new way of viewing familiar data, in particular the use of thematic maps with adjoining descriptive statistics and forest plots to support the generation and evaluation of new hypotheses. A series of qualitative evaluations involved one experienced researcher asking 21 volunteers to interact with the system to perform a series of relatively complex, realistic map-building and exploration tasks, using a 'think aloud' protocol, followed by a semi-structured interview The volunteers were academic epidemiologists and UK National Health Service analysts. All users quickly and confidently created maps, and went on to spend substantial amounts of time exploring and interacting with system, generating hypotheses about their maps. Our findings suggest that the tool is able to support creativity and statistical appreciation among public health professionals and epidemiologists building thematic maps. Software such as this, introduced appropriately, could increase the capability of existing personnel for generating public health intelligence.

  4. Community organization moderates the effect of alcohol outlet density on violence.

    PubMed

    Pridemore, William Alex; Grubesic, Tony H

    2012-12-01

    There is growing evidence from multiple disciplines that alcohol outlet density is associated with community levels of assault. Based on the theoretical and empirical literatures on social organization and crime, we tested the hypothesis that the association between alcohol outlet density and neighbourhood violence rates is moderated by social organization. Using geocoded police data on assaults, geocoded data on the location of alcohol outlets, and controlling for several structural factors thought to be associated with violence rates, we tested this hypothesis employing negative binomial regression with our sample of 298 block groups in Cincinnati. Our results revealed direct effects of alcohol outlet density and social organization on assault density, and these effects held for different outlet types (i.e., off-premise, bars, restaurants) and levels of harm (i.e., simple and aggravated assaults). More importantly, we found that the strength of the outlet-assault association was significantly weaker in more socially organized communities. Subsequent analyses by level of organization revealed no effects of alcohol outlet density on aggravated assaults in organized block groups, but significant effects in disorganized block groups. We found no association between social (dis)organization and outlet density. These results clarify the community-level relationship between alcohol outlets and violence and have important implications for municipal-level alcohol policies. © London School of Economics and Political Science 2012.

  5. Decisions to shoot in a weapon identification task: The influence of cultural stereotypes and perceived threat on false positive errors.

    PubMed

    Fleming, Kevin K; Bandy, Carole L; Kimble, Matthew O

    2010-01-01

    The decision to shoot a gun engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC), where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and electroencephalogram (EEG) activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of Middle-Eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERNs were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERNs, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of Middle-Eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to Middle-Eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance.

  6. Decisions to Shoot in a Weapon Identification Task: The Influence of Cultural Stereotypes and Perceived Threat on False Positive Errors

    PubMed Central

    Fleming, Kevin K.; Bandy, Carole L.; Kimble, Matthew O.

    2014-01-01

    The decision to shoot engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC) where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and EEG activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of middle-eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERN’s were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERN’s, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of middle-eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to middle-eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance. PMID:19813139

  7. Effect of surgical guide design and surgeon's experience on the accuracy of implant placement.

    PubMed

    Hinckfuss, Simon; Conrad, Heather J; Lin, Lianshan; Lunos, Scott; Seong, Wook-Jin

    2012-08-01

    Implant position is a key determinant of esthetic and functional success. Achieving the goal of ideal implant position may be affected by case selection, prosthodontically driven treatment planning, site preparation, surgeon's experience and use of a surgical guide. The combined effect of surgical guide design, surgeon's experience, and size of the edentulous area on the accuracy of implant placement was evaluated in a simulated clinical setting. Twenty-one volunteers were recruited to participate in the study. They were divided evenly into 3 groups (novice, intermediate, and experienced). Each surgeon placed implants in single and double sites using 4 different surgical guide designs (no guide, tube, channel, and guided) and written instructions describing the ideal implant positions. A definitive typodont was constructed that had 3 implants in prosthetically determined ideal positions of single and double sites. The position and angulation of implants placed by the surgeons in the duplicate typodonts was measured using a computerized coordinate measuring machine and compared to the definitive typodont. The mean absolute positional error for all guides was 0.273, 0.340, 0.197 mm in mesial-distal, buccal-lingual, vertical positions, respectively, with an overall range of 0.00 to 1.81 mm. The mean absolute angle error for all guides was 1.61° and 2.39° in the mesial-distal and buccal-lingual angulations, respectively, with an overall range of 0.01° to 9.7°. Surgical guide design had a statistically significant effect on the accuracy of implant placement regardless of the surgeon's experience level. Experienced surgeons had significantly less error in buccal-lingual angulation. The size of the edentulous sites was found to affect both implant angle and position significantly. The magnitude of error in position and angulation caused by surgical guide design, surgeon's experience, and site size reported in this study are possibly not large enough to be clinically significant; however, it is likely that errors would be magnified in clinical practice. Future research is recommended to evaluate the effect of surgical guide design in vivo on implant angulation and position error.

  8. Global distortion of GPS networks associated with satellite antenna model errors

    NASA Astrophysics Data System (ADS)

    Cardellach, E.; Elósegui, P.; Davis, J. L.

    2007-07-01

    Recent studies of the GPS satellite phase center offsets (PCOs) suggest that these have been in error by ˜1 m. Previous studies had shown that PCO errors are absorbed mainly by parameters representing satellite clock and the radial components of site position. On the basis of the assumption that the radial errors are equal, PCO errors will therefore introduce an error in network scale. However, PCO errors also introduce distortions, or apparent deformations, within the network, primarily in the radial (vertical) component of site position that cannot be corrected via a Helmert transformation. Using numerical simulations to quantify the effects of PCO errors, we found that these PCO errors lead to a vertical network distortion of 6-12 mm per meter of PCO error. The network distortion depends on the minimum elevation angle used in the analysis of the GPS phase observables, becoming larger as the minimum elevation angle increases. The steady evolution of the GPS constellation as new satellites are launched, age, and are decommissioned, leads to the effects of PCO errors varying with time that introduce an apparent global-scale rate change. We demonstrate here that current estimates for PCO errors result in a geographically variable error in the vertical rate at the 1-2 mm yr-1 level, which will impact high-precision crustal deformation studies.

  9. Global Distortion of GPS Networks Associated with Satellite Antenna Model Errors

    NASA Technical Reports Server (NTRS)

    Cardellach, E.; Elosequi, P.; Davis, J. L.

    2007-01-01

    Recent studies of the GPS satellite phase center offsets (PCOs) suggest that these have been in error by approx.1 m. Previous studies had shown that PCO errors are absorbed mainly by parameters representing satellite clock and the radial components of site position. On the basis of the assumption that the radial errors are equal, PCO errors will therefore introduce an error in network scale. However, PCO errors also introduce distortions, or apparent deformations, within the network, primarily in the radial (vertical) component of site position that cannot be corrected via a Helmert transformation. Using numerical simulations to quantify the effects of PC0 errors, we found that these PCO errors lead to a vertical network distortion of 6-12 mm per meter of PCO error. The network distortion depends on the minimum elevation angle used in the analysis of the GPS phase observables, becoming larger as the minimum elevation angle increases. The steady evolution of the GPS constellation as new satellites are launched, age, and are decommissioned, leads to the effects of PCO errors varying with time that introduce an apparent global-scale rate change. We demonstrate here that current estimates for PCO errors result in a geographically variable error in the vertical rate at the 1-2 mm/yr level, which will impact high-precision crustal deformation studies.

  10. SU-E-T-325: The New Evaluation Method of the VMAT Plan Delivery Using Varian DynaLog Files and Modulation Complexity Score (MCS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tateoka, K; Graduate School of Medicine, Sapporo Medical University, Sapporo, JP; Fujimomo, K

    2014-06-01

    Purpose: The aim of the study is to evaluate the use of Varian DynaLog files to verify VMAT plans delivery and modulation complexity score (MCS) of VMAT. Methods: Delivery accuracy of machine performance was quantified by multileaf collimator (MLC) position errors, gantry angle errors and fluence delivery accuracy for volumetric modulated arc therapy (VMAT). The relationship between machine performance and plan complexity were also investigated using the modulation complexity score (MCS). Plan and Actual MLC positions, gantry angles and delivered fraction of monitor units were extracted from Varian DynaLog files. These factors were taken from the record and verify systemmore » of MLC control file. Planned and delivered beam data were compared to determine leaf position errors and gantry angle errors. Analysis was also performed on planned and actual fluence maps reconstructed from those of the DynaLog files. This analysis was performed for all treatment fractions of 5 prostate VMAT plans. The analysis of DynaLog files have been carried out by in-house programming in Visual C++. Results: The root mean square of leaf position and gantry angle errors were about 0.12 and 0.15, respectively. The Gamma of planned and actual fluence maps at 3%/3 mm criterion was about 99.21. The gamma of the leaf position errors were not directly related to plan complexity as determined by the MCS. Therefore, the gamma of the gantry angle errors were directly related to plan complexity as determined by the MCS. Conclusion: This study shows Varian dynalog files for VMAT plan can be diagnosed delivery errors not possible with phantom based quality assurance. Furthermore, the MCS of VMAT plan can evaluate delivery accuracy for patients receiving of VMAT. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Juan; Beltran, Chris J., E-mail: beltran.chris@mayo.edu; Herman, Michael G.

    Purpose: To quantitatively and systematically assess dosimetric effects induced by spot positioning error as a function of spot spacing (SS) on intensity-modulated proton therapy (IMPT) plan quality and to facilitate evaluation of safety tolerance limits on spot position. Methods: Spot position errors (PE) ranging from 1 to 2 mm were simulated. Simple plans were created on a water phantom, and IMPT plans were calculated on two pediatric patients with a brain tumor of 28 and 3 cc, respectively, using a commercial planning system. For the phantom, a uniform dose was delivered to targets located at different depths from 10 tomore » 20 cm with various field sizes from 2{sup 2} to 15{sup 2} cm{sup 2}. Two nominal spot sizes, 4.0 and 6.6 mm of 1 σ in water at isocenter, were used for treatment planning. The SS ranged from 0.5 σ to 1.5 σ, which is 2–6 mm for the small spot size and 3.3–9.9 mm for the large spot size. Various perturbation scenarios of a single spot error and systematic and random multiple spot errors were studied. To quantify the dosimetric effects, percent dose error (PDE) depth profiles and the value of percent dose error at the maximum dose difference (PDE [ΔDmax]) were used for evaluation. Results: A pair of hot and cold spots was created per spot shift. PDE[ΔDmax] is found to be a complex function of PE, SS, spot size, depth, and global spot distribution that can be well defined in simple models. For volumetric targets, the PDE [ΔDmax] is not noticeably affected by the change of field size or target volume within the studied ranges. In general, reducing SS decreased the dose error. For the facility studied, given a single spot error with a PE of 1.2 mm and for both spot sizes, a SS of 1σ resulted in a 2% maximum dose error; a SS larger than 1.25 σ substantially increased the dose error and its sensitivity to PE. A similar trend was observed in multiple spot errors (both systematic and random errors). Systematic PE can lead to noticeable hot spots along the field edges, which may be near critical structures. However, random PE showed minimal dose error. Conclusions: Dose error dependence for PE was quantitatively and systematically characterized and an analytic tool was built to simulate systematic and random errors for patient-specific IMPT. This information facilitates the determination of facility specific spot position error thresholds.« less

  12. Control method and system for hydraulic machines employing a dynamic joint motion model

    DOEpatents

    Danko, George [Reno, NV

    2011-11-22

    A control method and system for controlling a hydraulically actuated mechanical arm to perform a task, the mechanical arm optionally being a hydraulically actuated excavator arm. The method can include determining a dynamic model of the motion of the hydraulic arm for each hydraulic arm link by relating the input signal vector for each respective link to the output signal vector for the same link. Also the method can include determining an error signal for each link as the weighted sum of the differences between a measured position and a reference position and between the time derivatives of the measured position and the time derivatives of the reference position for each respective link. The weights used in the determination of the error signal can be determined from the constant coefficients of the dynamic model. The error signal can be applied in a closed negative feedback control loop to diminish or eliminate the error signal for each respective link.

  13. Synthesis of hover autopilots for rotary-wing VTOL aircraft

    NASA Technical Reports Server (NTRS)

    Hall, W. E.; Bryson, A. E., Jr.

    1972-01-01

    The practical situation is considered where imperfect information on only a few rotor and fuselage state variables is available. Filters are designed to estimate all the state variables from noisy measurements of fuselage pitch/roll angles and from noisy measurements of both fuselage and rotor pitch/roll angles. The mean square response of the vehicle to a very gusty, random wind is computed using various filter/controllers and is found to be quite satisfactory although, of course, not so good as when one has perfect information (idealized case). The second part of the report considers precision hover over a point on the ground. A vehicle model without rotor dynamics is used and feedback signals in position and integral of position error are added. The mean square response of the vehicle to a very gusty, random wind is computed, assuming perfect information feedback, and is found to be excellent. The integral error feedback gives zero position error for a steady wind, and smaller position error for a random wind.

  14. Collaborated measurement of three-dimensional position and orientation errors of assembled miniature devices with two vision systems

    NASA Astrophysics Data System (ADS)

    Wang, Xiaodong; Zhang, Wei; Luo, Yi; Yang, Weimin; Chen, Liang

    2013-01-01

    In assembly of miniature devices, the position and orientation of the parts to be assembled should be guaranteed during or after assembly. In some cases, the relative position or orientation errors among the parts can not be measured from only one direction using visual method, because of visual occlusion or for the features of parts located in a three-dimensional way. An automatic assembly system for precise miniature devices is introduced. In the modular assembly system, two machine vision systems were employed for measurement of the three-dimensionally distributed assembly errors. High resolution CCD cameras and high position repeatability precision stages were integrated to realize high precision measurement in large work space. The two cameras worked in collaboration in measurement procedure to eliminate the influence of movement errors of the rotational or translational stages. A set of templates were designed for calibration of the vision systems and evaluation of the system's measurement accuracy.

  15. The immediate effects of therapeutic keyboard music playing for finger training in adults undergoing hand rehabilitation.

    PubMed

    Zhang, Xiaoying; Liu, Songhuai; Yang, Degang; Du, Liangjie; Wang, Ziyuan

    2016-08-01

    [Purpose] The purpose of this study was to examine the immediate effects of therapeutic keyboard music playing on the finger function of subjects' hands through measurements of the joint position error test, surface electromyography, probe reaction time, and writing time. [Subjects and Methods] Ten subjects were divided randomly into experimental and control groups. The experimental group used therapeutic keyboard music playing and the control group used grip training. All subjects were assessed and evaluated by the joint position error test, surface electromyography, probe reaction time, and writing time. [Results] After accomplishing therapeutic keyboard music playing and grip training, surface electromyography of the two groups showed no significant change, but joint position error test, probe reaction time, and writing time obviously improved. [Conclusion] These results suggest that therapeutic keyboard music playing is an effective and novel treatment for improving joint position error test scores, probe reaction time, and writing time, and it should be promoted widely in clinics.

  16. Analysis of RDSS positioning accuracy based on RNSS wide area differential technique

    NASA Astrophysics Data System (ADS)

    Xing, Nan; Su, RanRan; Zhou, JianHua; Hu, XiaoGong; Gong, XiuQiang; Liu, Li; He, Feng; Guo, Rui; Ren, Hui; Hu, GuangMing; Zhang, Lei

    2013-10-01

    The BeiDou Navigation Satellite System (BDS) provides Radio Navigation Service System (RNSS) as well as Radio Determination Service System (RDSS). RDSS users can obtain positioning by responding the Master Control Center (MCC) inquiries to signal transmitted via GEO satellite transponder. The positioning result can be calculated with elevation constraint by MCC. The primary error sources affecting the RDSS positioning accuracy are the RDSS signal transceiver delay, atmospheric trans-mission delay and GEO satellite position error. During GEO orbit maneuver, poor orbit forecast accuracy significantly impacts RDSS services. A real-time 3-D orbital correction method based on wide-area differential technique is raised to correct the orbital error. Results from the observation shows that the method can successfully improve positioning precision during orbital maneuver, independent from the RDSS reference station. This improvement can reach 50% in maximum. Accurate calibration of the RDSS signal transceiver delay precision and digital elevation map may have a critical role in high precise RDSS positioning services.

  17. Describing Phonological Paraphasias in Three Variants of Primary Progressive Aphasia.

    PubMed

    Dalton, Sarah Grace Hudspeth; Shultz, Christine; Henry, Maya L; Hillis, Argye E; Richardson, Jessica D

    2018-03-01

    The purpose of this study was to describe the linguistic environment of phonological paraphasias in 3 variants of primary progressive aphasia (semantic, logopenic, and nonfluent) and to describe the profiles of paraphasia production for each of these variants. Discourse samples of 26 individuals diagnosed with primary progressive aphasia were investigated for phonological paraphasias using the criteria established for the Philadelphia Naming Test (Moss Rehabilitation Research Institute, 2013). Phonological paraphasias were coded for paraphasia type, part of speech of the target word, target word frequency, type of segment in error, word position of consonant errors, type of error, and degree of change in consonant errors. Eighteen individuals across the 3 variants produced phonological paraphasias. Most paraphasias were nonword, followed by formal, and then mixed, with errors primarily occurring on nouns and verbs, with relatively few on function words. Most errors were substitutions, followed by addition and deletion errors, and few sequencing errors. Errors were evenly distributed across vowels, consonant singletons, and clusters, with more errors occurring in initial and medial positions of words than in the final position of words. Most consonant errors consisted of only a single-feature change, with few 2- or 3-feature changes. Importantly, paraphasia productions by variant differed from these aggregate results, with unique production patterns for each variant. These results suggest that a system where paraphasias are coded as present versus absent may be insufficient to adequately distinguish between the 3 subtypes of PPA. The 3 variants demonstrate patterns that may be used to improve phenotyping and diagnostic sensitivity. These results should be integrated with recent findings on phonological processing and speech rate. Future research should attempt to replicate these results in a larger sample of participants with longer speech samples and varied elicitation tasks. https://doi.org/10.23641/asha.5558107.

  18. Pedestrian dead reckoning employing simultaneous activity recognition cues

    NASA Astrophysics Data System (ADS)

    Altun, Kerem; Barshan, Billur

    2012-02-01

    We consider the human localization problem using body-worn inertial/magnetic sensor units. Inertial sensors are characterized by a drift error caused by the integration of their rate output to obtain position information. Because of this drift, the position and orientation data obtained from inertial sensors are reliable over only short periods of time. Therefore, position updates from externally referenced sensors are essential. However, if the map of the environment is known, the activity context of the user can provide information about his position. In particular, the switches in the activity context correspond to discrete locations on the map. By performing localization simultaneously with activity recognition, we detect the activity context switches and use the corresponding position information as position updates in a localization filter. The localization filter also involves a smoother that combines the two estimates obtained by running the zero-velocity update algorithm both forward and backward in time. We performed experiments with eight subjects in indoor and outdoor environments involving walking, turning and standing activities. Using a spatial error criterion, we show that the position errors can be decreased by about 85% on the average. We also present the results of two 3D experiments performed in realistic indoor environments and demonstrate that it is possible to achieve over 90% error reduction in position by performing localization simultaneously with activity recognition.

  19. Cognitive control of conscious error awareness: error awareness and error positivity (Pe) amplitude in moderate-to-severe traumatic brain injury (TBI)

    PubMed Central

    Logan, Dustin M.; Hill, Kyle R.; Larson, Michael J.

    2015-01-01

    Poor awareness has been linked to worse recovery and rehabilitation outcomes following moderate-to-severe traumatic brain injury (M/S TBI). The error positivity (Pe) component of the event-related potential (ERP) is linked to error awareness and cognitive control. Participants included 37 neurologically healthy controls and 24 individuals with M/S TBI who completed a brief neuropsychological battery and the error awareness task (EAT), a modified Stroop go/no-go task that elicits aware and unaware errors. Analyses compared between-group no-go accuracy (including accuracy between the first and second halves of the task to measure attention and fatigue), error awareness performance, and Pe amplitude by level of awareness. The M/S TBI group decreased in accuracy and maintained error awareness over time; control participants improved both accuracy and error awareness during the course of the task. Pe amplitude was larger for aware than unaware errors for both groups; however, consistent with previous research on the Pe and TBI, there were no significant between-group differences for Pe amplitudes. Findings suggest possible attention difficulties and low improvement of performance over time may influence specific aspects of error awareness in M/S TBI. PMID:26217212

  20. Acetaminophen attenuates error evaluation in cortex.

    PubMed

    Randles, Daniel; Kam, Julia W Y; Heine, Steven J; Inzlicht, Michael; Handy, Todd C

    2016-06-01

    Acetaminophen has recently been recognized as having impacts that extend into the affective domain. In particular, double blind placebo controlled trials have revealed that acetaminophen reduces the magnitude of reactivity to social rejection, frustration, dissonance and to both negatively and positively valenced attitude objects. Given this diversity of consequences, it has been proposed that the psychological effects of acetaminophen may reflect a widespread blunting of evaluative processing. We tested this hypothesis using event-related potentials (ERPs). Sixty-two participants received acetaminophen or a placebo in a double-blind protocol and completed the Go/NoGo task. Participants' ERPs were observed following errors on the Go/NoGo task, in particular the error-related negativity (ERN; measured at FCz) and error-related positivity (Pe; measured at Pz and CPz). Results show that acetaminophen inhibits the Pe, but not the ERN, and the magnitude of an individual's Pe correlates positively with omission errors, partially mediating the effects of acetaminophen on the error rate. These results suggest that recently documented affective blunting caused by acetaminophen may best be described as an inhibition of evaluative processing. They also contribute to the growing work suggesting that the Pe is more strongly associated with conscious awareness of errors relative to the ERN. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  1. Digital to synchro converter

    NASA Technical Reports Server (NTRS)

    Predina, Joseph P. (Inventor)

    1989-01-01

    A digital-to-synchro converter is provided where a binary input code specifies a desired shaft angle and where an resolver type position transducer is employed with additional circuitry to generate a shaft position error signal indicative of the angular difference between the desired shaft angle and the actual shaft angle. The additional circuitry corrects for known and calculated errors in the shaft position detection process and equipment.

  2. The effect of hip positioning on the projected femoral neck-shaft angle: a modeling study.

    PubMed

    Bhashyam, Abhiram R; Rodriguez, Edward K; Appleton, Paul; Wixted, John J

    2018-04-03

    The femoral neck-shaft angle (NSA) is used to restore normal hip geometry during hip fracture repair. Femoral rotation is known to affect NSA measurement, but the effect of hip flexion-extension is unknown. The goals of this study were to determine and test mathematical models of the relationship between hip flexion-extension, femoral rotation and NSA. We hypothesized that hip flexion-extension and femoral rotation would result in NSA measurement error. Two mathematical models were developed to predict NSA in varying degrees of hip flexion-extension and femoral rotation. The predictions of the equations were tested in vitro using a model that varied hip flexion-extension while keeping rotation constant, and vice versa. The NSA was measured from an AP radiograph obtained with a C-arm. Attributable measurement error based on hip positioning was calculated from the models. The predictions of the model correlated well with the experimental data (correlation coefficient = 0.82 - 0.90). A wide range of patient positioning was found to result in less than 5-10 degree error in the measurement of NSA. Hip flexion-extension and femoral rotation had a synergistic effect in measurement error of the NSA. Measurement error was minimized when hip flexion-extension was within 10 degrees of neutral. This study demonstrates that hip flexion-extension and femoral rotation significantly affect the measurement of the NSA. To avoid inadvertently fixing the proximal femur in varus or valgus, the hip should be positioned within 10 degrees of neutral flexion-extension with respect to the C-arm to minimize positional measurement error. N/A, basic science study.

  3. Systematic Errors in an Air Track Experiment.

    ERIC Educational Resources Information Center

    Ramirez, Santos A.; Ham, Joe S.

    1990-01-01

    Errors found in a common physics experiment to measure acceleration resulting from gravity using a linear air track are investigated. Glider position at release and initial velocity are shown to be sources of systematic error. (CW)

  4. Positive Beliefs about Errors as an Important Element of Adaptive Individual Dealing with Errors during Academic Learning

    ERIC Educational Resources Information Center

    Tulis, Maria; Steuer, Gabriele; Dresel, Markus

    2018-01-01

    Research on learning from errors gives reason to assume that errors provide a high potential to facilitate deep learning if students are willing and able to take these learning opportunities. The first aim of this study was to analyse whether beliefs about errors as learning opportunities can be theoretically and empirically distinguished from…

  5. Error measuring system of rotary Inductosyn

    NASA Astrophysics Data System (ADS)

    Liu, Chengjun; Zou, Jibin; Fu, Xinghe

    2008-10-01

    The inductosyn is a kind of high-precision angle-position sensor. It has important applications in servo table, precision machine tool and other products. The precision of inductosyn is calibrated by its error. It's an important problem about the error measurement in the process of production and application of the inductosyn. At present, it mainly depends on the method of artificial measurement to obtain the error of inductosyn. Therefore, the disadvantages can't be ignored such as the high labour intensity of the operator, the occurrent error which is easy occurred and the poor repeatability, and so on. In order to solve these problems, a new automatic measurement method is put forward in this paper which based on a high precision optical dividing head. Error signal can be obtained by processing the output signal of inductosyn and optical dividing head precisely. When inductosyn rotating continuously, its zero position error can be measured dynamically, and zero error curves can be output automatically. The measuring and calculating errors caused by man-made factor can be overcome by this method, and it makes measuring process more quickly, exactly and reliably. Experiment proves that the accuracy of error measuring system is 1.1 arc-second (peak - peak value).

  6. SU-G-BRB-03: Assessing the Sensitivity and False Positive Rate of the Integrated Quality Monitor (IQM) Large Area Ion Chamber to MLC Positioning Errors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boehnke, E McKenzie; DeMarco, J; Steers, J

    2016-06-15

    Purpose: To examine both the IQM’s sensitivity and false positive rate to varying MLC errors. By balancing these two characteristics, an optimal tolerance value can be derived. Methods: An un-modified SBRT Liver IMRT plan containing 7 fields was randomly selected as a representative clinical case. The active MLC positions for all fields were perturbed randomly from a square distribution of varying width (±1mm to ±5mm). These unmodified and modified plans were measured multiple times each by the IQM (a large area ion chamber mounted to a TrueBeam linac head). Measurements were analyzed relative to the initial, unmodified measurement. IQM readingsmore » are analyzed as a function of control points. In order to examine sensitivity to errors along a field’s delivery, each measured field was divided into 5 groups of control points, and the maximum error in each group was recorded. Since the plans have known errors, we compared how well the IQM is able to differentiate between unmodified and error plans. ROC curves and logistic regression were used to analyze this, independent of thresholds. Results: A likelihood-ratio Chi-square test showed that the IQM could significantly predict whether a plan had MLC errors, with the exception of the beginning and ending control points. Upon further examination, we determined there was ramp-up occurring at the beginning of delivery. Once the linac AFC was tuned, the subsequent measurements (relative to a new baseline) showed significant (p <0.005) abilities to predict MLC errors. Using the area under the curve, we show the IQM’s ability to detect errors increases with increasing MLC error (Spearman’s Rho=0.8056, p<0.0001). The optimal IQM count thresholds from the ROC curves are ±3%, ±2%, and ±7% for the beginning, middle 3, and end segments, respectively. Conclusion: The IQM has proven to be able to detect not only MLC errors, but also differences in beam tuning (ramp-up). Partially supported by the Susan Scott Foundation.« less

  7. Neighborhood Effects on Health: Concentrated Advantage and Disadvantage

    PubMed Central

    Finch, Brian K.; Do, D. Phuong; Heron, Melonie; Bird, Chloe; Seeman, Teresa; Lurie, Nicole

    2010-01-01

    We investigate an alternative conceptualization of neighborhood context and its association with health. Using an index that measures a continuum of concentrated advantage and disadvantage, we examine whether the relationship between neighborhood conditions and health varies by socio-economic status. Using NHANES III data geo-coded to census tracts, we find that while largely uneducated neighborhoods are universally deleterious, individuals with more education benefit from living in highly educated neighborhoods to a greater degree than individuals with lower levels of education. PMID:20627796

  8. A novel method for routine quality assurance of volumetric-modulated arc therapy.

    PubMed

    Wang, Qingxin; Dai, Jianrong; Zhang, Ke

    2013-10-01

    Volumetric-modulated arc therapy (VMAT) is delivered through synchronized variation of gantry angle, dose rate, and multileaf collimator (MLC) leaf positions. The delivery dynamic nature challenges the parameter setting accuracy of linac control system. The purpose of this study was to develop a novel method for routine quality assurance (QA) of VMAT linacs. ArcCheck is a detector array with diodes distributing in spiral pattern on cylindrical surface. Utilizing its features, a QA plan was designed to strictly test all varying parameters during VMAT delivery on an Elekta Synergy linac. In this plan, there are 24 control points. The gantry rotates clockwise from 181° to 179°. The dose rate, gantry speed, and MLC positions cover their ranges commonly used in clinic. The two borders of MLC-shaped field seat over two columns of diodes of ArcCheck when the gantry rotates to the angle specified by each control point. The ratio of dose rate between each of these diodes and the diode closest to the field center is a certain value and sensitive to the MLC positioning error of the leaf crossing the diode. Consequently, the positioning error can be determined by the ratio with the help of a relationship curve. The time when the gantry reaches the angle specified by each control point can be acquired from the virtual inclinometer that is a feature of ArcCheck. The gantry speed between two consecutive control points is then calculated. The aforementioned dose rate is calculated from an acm file that is generated during ArcCheck measurements. This file stores the data measured by each detector in 50 ms updates with each update in a separate row. A computer program was written in MATLAB language to process the data. The program output included MLC positioning errors and the dose rate at each control point as well as the gantry speed between control points. To evaluate this method, this plan was delivered for four consecutive weeks. The actual dose rate and gantry speed were compared with the QA plan specified. Additionally, leaf positioning errors were intentionally introduced to investigate the sensitivity of this method. The relationship curves were established for detecting MLC positioning errors during VMAT delivery. For four consecutive weeks measured, 98.4%, 94.9%, 89.2%, and 91.0% of the leaf positioning errors were within ± 0.5 mm, respectively. For the intentionally introduced leaf positioning systematic errors of -0.5 and +1 mm, the detected leaf positioning errors of 20 Y1 leaf were -0.48 ± 0.14 and 1.02 ± 0.26 mm, respectively. The actual gantry speed and dose rate closely followed the values specified in the VMAT QA plan. This method can assess the accuracy of MLC positions and the dose rate at each control point as well as the gantry speed between control points at the same time. It is efficient and suitable for routine quality assurance of VMAT.

  9. A Novel Error Model of Optical Systems and an On-Orbit Calibration Method for Star Sensors.

    PubMed

    Wang, Shuang; Geng, Yunhai; Jin, Rongyu

    2015-12-12

    In order to improve the on-orbit measurement accuracy of star sensors, the effects of image-plane rotary error, image-plane tilt error and distortions of optical systems resulting from the on-orbit thermal environment were studied in this paper. Since these issues will affect the precision of star image point positions, in this paper, a novel measurement error model based on the traditional error model is explored. Due to the orthonormal characteristics of image-plane rotary-tilt errors and the strong nonlinearity among these error parameters, it is difficult to calibrate all the parameters simultaneously. To solve this difficulty, for the new error model, a modified two-step calibration method based on the Extended Kalman Filter (EKF) and Least Square Methods (LSM) is presented. The former one is used to calibrate the main point drift, focal length error and distortions of optical systems while the latter estimates the image-plane rotary-tilt errors. With this calibration method, the precision of star image point position influenced by the above errors is greatly improved from 15.42% to 1.389%. Finally, the simulation results demonstrate that the presented measurement error model for star sensors has higher precision. Moreover, the proposed two-step method can effectively calibrate model error parameters, and the calibration precision of on-orbit star sensors is also improved obviously.

  10. Angular sensitivities of scintillator slab configurations for location of gamma ray bursts

    NASA Technical Reports Server (NTRS)

    Gregory, J. C.

    1976-01-01

    Thin flat scintillator slabs are a useful means of measuring the angular location of gamma ray fluxes of astronomical interest. A statistical estimate of position error was made of two scintillator systems suitable for gamma ray burst location from a balloon or satellite platform. A single rotating scintillator with associated flux monitor is compared with a pair of stationary orthogonal scintillators. Position error for a strong burst is of the order of a few arcmin if systematic errors are ignored.

  11. Disturbance torque rejection properties of the NASA/JPL 70-meter antenna axis servos

    NASA Technical Reports Server (NTRS)

    Hill, R. E.

    1989-01-01

    Analytic methods for evaluating pointing errors caused by external disturbance torques are developed and applied to determine the effects of representative values of wind and friction torque. The expressions relating pointing errors to disturbance torques are shown to be strongly dependent upon the state estimator parameters, as well as upon the state feedback gain and the flow versus pressure characteristics of the hydraulic system. Under certain conditions, when control is derived from an uncorrected estimate of integral position error, the desired type 2 servo properties are not realized and finite steady-state position errors result. Methods for reducing these errors to negligible proportions through the proper selection of control gain and estimator correction parameters are demonstrated. The steady-state error produced by a disturbance torque is found to be directly proportional to the hydraulic internal leakage. This property can be exploited to provide a convenient method of determining system leakage from field measurements of estimator error, axis rate, and hydraulic differential pressure.

  12. A wireless sensor network based personnel positioning scheme in coal mines with blind areas.

    PubMed

    Liu, Zhigao; Li, Chunwen; Wu, Danchen; Dai, Wenhan; Geng, Shaobo; Ding, Qingqing

    2010-01-01

    This paper proposes a novel personnel positioning scheme for a tunnel network with blind areas, which compared with most existing schemes offers both low-cost and high-precision. Based on the data models of tunnel networks, measurement networks and mobile miners, the global positioning method is divided into four steps: (1) calculate the real time personnel location in local areas using a location engine, and send it to the upper computer through the gateway; (2) correct any localization errors resulting from the underground tunnel environmental interference; (3) determine the global three-dimensional position by coordinate transformation; (4) estimate the personnel locations in the blind areas. A prototype system constructed to verify the positioning performance shows that the proposed positioning system has good reliability, scalability, and positioning performance. In particular, the static localization error of the positioning system is less than 2.4 m in the underground tunnel environment and the moving estimation error is below 4.5 m in the corridor environment. The system was operated continuously over three months without any failures.

  13. A Wireless Sensor Network Based Personnel Positioning Scheme in Coal Mines with Blind Areas

    PubMed Central

    Liu, Zhigao; Li, Chunwen; Wu, Danchen; Dai, Wenhan; Geng, Shaobo; Ding, Qingqing

    2010-01-01

    This paper proposes a novel personnel positioning scheme for a tunnel network with blind areas, which compared with most existing schemes offers both low-cost and high-precision. Based on the data models of tunnel networks, measurement networks and mobile miners, the global positioning method is divided into four steps: (1) calculate the real time personnel location in local areas using a location engine, and send it to the upper computer through the gateway; (2) correct any localization errors resulting from the underground tunnel environmental interference; (3) determine the global three-dimensional position by coordinate transformation; (4) estimate the personnel locations in the blind areas. A prototype system constructed to verify the positioning performance shows that the proposed positioning system has good reliability, scalability, and positioning performance. In particular, the static localization error of the positioning system is less than 2.4 m in the underground tunnel environment and the moving estimation error is below 4.5 m in the corridor environment. The system was operated continuously over three months without any failures. PMID:22163446

  14. Accuracy of an acoustic location system for monitoring the position of duetting songbirds in tropical forest

    PubMed Central

    Mennill, Daniel J.; Burt, John M.; Fristrup, Kurt M.; Vehrencamp, Sandra L.

    2008-01-01

    A field test was conducted on the accuracy of an eight-microphone acoustic location system designed to triangulate the position of duetting rufous-and-white wrens (Thryothorus rufalbus) in Costa Rica’s humid evergreen forest. Eight microphones were set up in the breeding territories of twenty pairs of wrens, with an average inter-microphone distance of 75.2±2.6 m. The array of microphones was used to record antiphonal duets broadcast through stereo loudspeakers. The positions of the loudspeakers were then estimated by evaluating the delay with which the eight microphones recorded the broadcast sounds. Position estimates were compared to coordinates surveyed with a global-positioning system (GPS). The acoustic location system estimated the position of loudspeakers with an error of 2.82±0.26 m and calculated the distance between the “male” and “female” loudspeakers with an error of 2.12±0.42 m. Given the large range of distances between duetting birds, this relatively low level of error demonstrates that the acoustic location system is a useful tool for studying avian duets. Location error was influenced partly by the difficulties inherent in collecting high accuracy GPS coordinates of microphone positions underneath a lush tropical canopy, and partly by the complicating influence of irregular topography and thick vegetation on sound transmission. PMID:16708941

  15. Real-Time Point Positioning Performance Evaluation of Single-Frequency Receivers Using NASA's Global Differential GPS System

    NASA Technical Reports Server (NTRS)

    Muellerschoen, Ronald J.; Iijima, Byron; Meyer, Robert; Bar-Sever, Yoaz; Accad, Elie

    2004-01-01

    This paper evaluates the performance of a single-frequency receiver using the 1-Hz differential corrections as provided by NASA's global differential GPS system. While the dual-frequency user has the ability to eliminate the ionosphere error by taking a linear combination of observables, the single-frequency user must remove or calibrate this error by other means. To remove the ionosphere error we take advantage of the fact that the magnitude of the group delay in range observable and the carrier phase advance have the same magnitude but are opposite in sign. A way to calibrate this error is to use a real-time database of grid points computed by JPL's RTI (Real-Time Ionosphere) software. In both cases we evaluate the positional accuracy of a kinematic carrier phase based point positioning method on a global extent.

  16. Improving qPCR telomere length assays: Controlling for well position effects increases statistical power.

    PubMed

    Eisenberg, Dan T A; Kuzawa, Christopher W; Hayes, M Geoffrey

    2015-01-01

    Telomere length (TL) is commonly measured using quantitative PCR (qPCR). Although, easier than the southern blot of terminal restriction fragments (TRF) TL measurement method, one drawback of qPCR is that it introduces greater measurement error and thus reduces the statistical power of analyses. To address a potential source of measurement error, we consider the effect of well position on qPCR TL measurements. qPCR TL data from 3,638 people run on a Bio-Rad iCycler iQ are reanalyzed here. To evaluate measurement validity, correspondence with TRF, age, and between mother and offspring are examined. First, we present evidence for systematic variation in qPCR TL measurements in relation to thermocycler well position. Controlling for these well-position effects consistently improves measurement validity and yields estimated improvements in statistical power equivalent to increasing sample sizes by 16%. We additionally evaluated the linearity of the relationships between telomere and single copy gene control amplicons and between qPCR and TRF measures. We find that, unlike some previous reports, our data exhibit linear relationships. We introduce the standard error in percent, a superior method for quantifying measurement error as compared to the commonly used coefficient of variation. Using this measure, we find that excluding samples with high measurement error does not improve measurement validity in our study. Future studies using block-based thermocyclers should consider well position effects. Since additional information can be gleaned from well position corrections, rerunning analyses of previous results with well position correction could serve as an independent test of the validity of these results. © 2015 Wiley Periodicals, Inc.

  17. Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques.

    PubMed

    Hampp, Emily L; Chughtai, Morad; Scholl, Laura Y; Sodhi, Nipun; Bhowmik-Stoker, Manoshi; Jacofsky, David J; Mont, Michael A

    2018-05-01

    This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements ( p  ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements ( p  ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Unexpected but Incidental Positive Outcomes Predict Real-World Gambling.

    PubMed

    Otto, A Ross; Fleming, Stephen M; Glimcher, Paul W

    2016-03-01

    Positive mood can affect a person's tendency to gamble, possibly because positive mood fosters unrealistic optimism. At the same time, unexpected positive outcomes, often called prediction errors, influence mood. However, a linkage between positive prediction errors-the difference between expected and obtained outcomes-and consequent risk taking has yet to be demonstrated. Using a large data set of New York City lottery gambling and a model inspired by computational accounts of reward learning, we found that people gamble more when incidental outcomes in the environment (e.g., local sporting events and sunshine) are better than expected. When local sports teams performed better than expected, or a sunny day followed a streak of cloudy days, residents gambled more. The observed relationship between prediction errors and gambling was ubiquitous across the city's socioeconomically diverse neighborhoods and was specific to sports and weather events occurring locally in New York City. Our results suggest that unexpected but incidental positive outcomes influence risk taking. © The Author(s) 2016.

  19. Reliability and measurement error of active knee extension range of motion in a modified slump test position: a pilot study.

    PubMed

    Tucker, Neil; Reid, Duncan; McNair, Peter

    2007-01-01

    The slump test is a tool to assess the mechanosensitivity of the neuromeningeal structures within the vertebral canal. While some studies have investigated the reliability of aspects of this test within the same day, few have assessed the reliability across days. Therefore, the purpose of this pilot study was to investigate reliability when measuring active knee extension range of motion (AROM) in a modified slump test position within trials on a single day and across days. Ten male and ten female asymptomatic subjects, ages 20-49 (mean age 30.1, SD 6.4) participated in the study. Knee extension AROM in a modified slump position with the cervical spine in a flexed position and then in an extended position was measured via three trials on two separate days. Across three trials, knee extension AROM increased significantly with a mean magnitude of 2 degrees within days for both cervical spine positions (P>0.05). The findings showed that there was no statistically significant difference in knee extension AROM measurements across days (P>0.05). The intraclass correlation coefficients for the mean of the three trials across days were 0.96 (lower limit 95% CI: 0.90) with the cervical spine flexed and 0.93 (lower limit 95% CI: 0.83) with cervical extension. Measurement error was calculated by way of the typical error and 95% limits of agreement, and visually represented in Bland and Altman plots. The typical error for the cervical flexed and extended positions averaged across trials was 2.6 degrees and 3.3 degrees , respectively. The limits of agreement were narrow, and the Bland and Altman plots also showed minimal bias in the joint angles across days with a random distribution of errors across the range of measured angles. This study demonstrated that knee extension AROM could be reliably measured across days in subjects without pathology and that the measurement error was acceptable. Implications of variability over multiple trials are discussed. The modified set-up for the test using the Kincom dynamometer and elevated thigh position may be useful to clinical researchers in determining the mechanosensitivity of the nervous system.

  20. Reliability and Measurement Error of Active Knee Extension Range of Motion in a Modified Slump Test Position: A Pilot Study

    PubMed Central

    Tucker, Neil; Reid, Duncan; McNair, Peter

    2007-01-01

    The slump test is a tool to assess the mechanosensitivity of the neuromeningeal structures within the vertebral canal. While some studies have investigated the reliability of aspects of this test within the same day, few have assessed the reliability across days. Therefore, the purpose of this pilot study was to investigate reliability when measuring active knee extension range of motion (AROM) in a modified slump test position within trials on a single day and across days. Ten male and ten female asymptomatic subjects, ages 20–49 (mean age 30.1, SD 6.4) participated in the study. Knee extension AROM in a modified slump position with the cervical spine in a flexed position and then in an extended position was measured via three trials on two separate days. Across three trials, knee extension AROM increased significantly with a mean magnitude of 2° within days for both cervical spine positions (P>0.05). The findings showed that there was no statistically significant difference in knee extension AROM measurements across days (P>0.05). The intraclass correlation coefficients for the mean of the three trials across days were 0.96 (lower limit 95% CI: 0.90) with the cervical spine flexed and 0.93 (lower limit 95% CI: 0.83) with cervical extension. Measurement error was calculated by way of the typical error and 95% limits of agreement, and visually represented in Bland and Altman plots. The typical error for the cervical flexed and extended positions averaged across trials was 2.6° and 3.3°, respectively. The limits of agreement were narrow, and the Bland and Altman plots also showed minimal bias in the joint angles across days with a random distribution of errors across the range of measured angles. This study demonstrated that knee extension AROM could be reliably measured across days in subjects without pathology and that the measurement error was acceptable. Implications of variability over multiple trials are discussed. The modified set-up for the test using the Kincom dynamometer and elevated thigh position may be useful to clinical researchers in determining the mechanosensitivity of the nervous system. PMID:19066666

  1. Operator Variability in Scan Positioning is a Major Component of HR-pQCT Precision Error and is Reduced by Standardized Training

    PubMed Central

    Bonaretti, Serena; Vilayphiou, Nicolas; Chan, Caroline Mai; Yu, Andrew; Nishiyama, Kyle; Liu, Danmei; Boutroy, Stephanie; Ghasem-Zadeh, Ali; Boyd, Steven K.; Chapurlat, Roland; McKay, Heather; Shane, Elizabeth; Bouxsein, Mary L.; Black, Dennis M.; Majumdar, Sharmila; Orwoll, Eric S.; Lang, Thomas F.; Khosla, Sundeep; Burghardt, Andrew J.

    2017-01-01

    Introduction HR-pQCT is increasingly used to assess bone quality, fracture risk and anti-fracture interventions. The contribution of the operator has not been adequately accounted in measurement precision. Operators acquire a 2D projection (“scout view image”) and define the region to be scanned by positioning a “reference line” on a standard anatomical landmark. In this study, we (i) evaluated the contribution of positioning variability to in vivo measurement precision, (ii) measured intra- and inter-operator positioning variability, and (iii) tested if custom training software led to superior reproducibility in new operators compared to experienced operators. Methods To evaluate the operator in vivo measurement precision we compared precision errors calculated in 64 co-registered and non-co-registered scan-rescan images. To quantify operator variability, we developed software that simulates the positioning process of the scanner’s software. Eight experienced operators positioned reference lines on scout view images designed to test intra- and inter-operator reproducibility. Finally, we developed modules for training and evaluation of reference line positioning. We enrolled 6 new operators to participate in a common training, followed by the same reproducibility experiments performed by the experienced group. Results In vivo precision errors were up to three-fold greater (Tt.BMD and Ct.Th) when variability in scan positioning was included. Inter-operator precision errors were significantly greater than short-term intra-operator precision (p<0.001). New trained operators achieved comparable intra-operator reproducibility to experienced operators, and lower inter-operator reproducibility (p<0.001). Precision errors were significantly greater for the radius than for the tibia. Conclusion Operator reference line positioning contributes significantly to in vivo measurement precision and is significantly greater for multi-operator datasets. Inter-operator variability can be significantly reduced using a systematic training platform, now available online (http://webapps.radiology.ucsf.edu/refline/). PMID:27475931

  2. Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Taoran, E-mail: taoran.li.duke@gmail.com; Wu, Qiuwen; Yang, Yun

    Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system wasmore » designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Results: Online adapted plans were found to have similar delivery accuracy in comparison to clinical IMRT plans when validated with portal dosimetry IMRT QA. FEMs for the simulated deliveries with intentional MLC errors exhibited distinct patterns for different MLC error magnitudes and directions, indicating that the proposed delivery monitoring system is highly specific in detecting the source of errors. Implementing the proposed QA system for online adapted plans revealed excellent delivery accuracy: over 99% of leaf position differences were within 0.5 mm, and >99% of pixels in the FEMs had fluence errors within 0.5 MU. Patterns present in the FEMs and MLC control point analysis for actual patient cases agreed with the error pattern analysis results, further validating the system’s ability to reveal and differentiate MLC deviations. Calculation of the fluence map based on the DMI was performed within 2 ms after receiving each DMI input. Conclusions: The proposed online delivery monitoring system requires minimal additional resources and time commitment to the current clinical workflow while still maintaining high sensitivity to leaf position errors and specificity to error types. The presented online delivery monitoring system therefore represents a promising QA system candidate for online adaptive radiation therapy.« less

  3. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation.

    PubMed

    Li, Taoran; Wu, Qiuwen; Yang, Yun; Rodrigues, Anna; Yin, Fang-Fang; Jackie Wu, Q

    2015-01-01

    An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system's performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Online adapted plans were found to have similar delivery accuracy in comparison to clinical IMRT plans when validated with portal dosimetry IMRT QA. FEMs for the simulated deliveries with intentional MLC errors exhibited distinct patterns for different MLC error magnitudes and directions, indicating that the proposed delivery monitoring system is highly specific in detecting the source of errors. Implementing the proposed QA system for online adapted plans revealed excellent delivery accuracy: over 99% of leaf position differences were within 0.5 mm, and >99% of pixels in the FEMs had fluence errors within 0.5 MU. Patterns present in the FEMs and MLC control point analysis for actual patient cases agreed with the error pattern analysis results, further validating the system's ability to reveal and differentiate MLC deviations. Calculation of the fluence map based on the DMI was performed within 2 ms after receiving each DMI input. The proposed online delivery monitoring system requires minimal additional resources and time commitment to the current clinical workflow while still maintaining high sensitivity to leaf position errors and specificity to error types. The presented online delivery monitoring system therefore represents a promising QA system candidate for online adaptive radiation therapy.

  4. Final report on the development of the geographic position locator (GPL). Volume 12. Data reduction A3FIX: subroutine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Niven, W.A.

    The long-term position accuracy of an inertial navigation system depends primarily on the ability of the gyroscopes to maintain a near-perfect reference orientation. Small imperfections in the gyroscopes cause them to drift slowly away from their initial orientation, thereby producing errors in the system's calculations of position. The A3FIX is a computer program subroutine developed to estimate inertial navigation system gyro drift rates with the navigator stopped or moving slowly. It processes data of the navigation system's position error to arrive at estimates of the north- south and vertical gyro drift rates. It also computes changes in the east--west gyromore » drift rate if the navigator is stopped and if data on the system's azimuth error changes are also available. The report describes the subroutine, its capabilities, and gives examples of gyro drift rate estimates that were computed during the testing of a high quality inertial system under the PASSPORT program at the Lawrence Livermore Laboratory. The appendices provide mathematical derivations of the estimation equations that are used in the subroutine, a discussion of the estimation errors, and a program listing and flow diagram. The appendices also contain a derivation of closed form solutions to the navigation equations to clarify the effects that motion and time-varying drift rates induce in the phase-plane relationships between the Schulerfiltered errors in latitude and azimuth snd between the Schulerfiltered errors in latitude and longitude. (auth)« less

  5. Study on the three-station typical network deployments of workspace Measurement and Positioning System

    NASA Astrophysics Data System (ADS)

    Xiong, Zhi; Zhu, J. G.; Xue, B.; Ye, Sh. H.; Xiong, Y.

    2013-10-01

    As a novel network coordinate measurement system based on multi-directional positioning, workspace Measurement and Positioning System (wMPS) has outstanding advantages of good parallelism, wide measurement range and high measurement accuracy, which makes it to be the research hotspots and important development direction in the field of large-scale measurement. Since station deployment has a significant impact on the measurement range and accuracy, and also restricts the use-cost, the optimization method of station deployment was researched in this paper. Firstly, positioning error model was established. Then focusing on the small network consisted of three stations, the typical deployments and error distribution characteristics were studied. Finally, through measuring the simulated fuselage using typical deployments at the industrial spot and comparing the results with Laser Tracker, some conclusions are obtained. The comparison results show that under existing prototype conditions, I_3 typical deployment of which three stations are distributed in a straight line has an average error of 0.30 mm and the maximum error is 0.50 mm in the range of 12 m. Meanwhile, C_3 typical deployment of which three stations are uniformly distributed in the half-circumference of an circle has an average error of 0.17 mm and the maximum error is 0.28 mm. Obviously, C_3 typical deployment has a higher control effect on precision than I_3 type. The research work provides effective theoretical support for global measurement network optimization in the future work.

  6. Efficacy and workload analysis of a fixed vertical couch position technique and a fixed‐action–level protocol in whole‐breast radiotherapy

    PubMed Central

    Verhoeven, Karolien; Weltens, Caroline; Van den Heuvel, Frank

    2015-01-01

    Quantification of the setup errors is vital to define appropriate setup margins preventing geographical misses. The no‐action–level (NAL) correction protocol reduces the systematic setup errors and, hence, the setup margins. The manual entry of the setup corrections in the record‐and‐verify software, however, increases the susceptibility of the NAL protocol to human errors. Moreover, the impact of the skin mobility on the anteroposterior patient setup reproducibility in whole‐breast radiotherapy (WBRT) is unknown. In this study, we therefore investigated the potential of fixed vertical couch position‐based patient setup in WBRT. The possibility to introduce a threshold for correction of the systematic setup errors was also explored. We measured the anteroposterior, mediolateral, and superior–inferior setup errors during fractions 1–12 and weekly thereafter with tangential angled single modality paired imaging. These setup data were used to simulate the residual setup errors of the NAL protocol, the fixed vertical couch position protocol, and the fixed‐action–level protocol with different correction thresholds. Population statistics of the setup errors of 20 breast cancer patients and 20 breast cancer patients with additional regional lymph node (LN) irradiation were calculated to determine the setup margins of each off‐line correction protocol. Our data showed the potential of the fixed vertical couch position protocol to restrict the systematic and random anteroposterior residual setup errors to 1.8 mm and 2.2 mm, respectively. Compared to the NAL protocol, a correction threshold of 2.5 mm reduced the frequency of mediolateral and superior–inferior setup corrections with 40% and 63%, respectively. The implementation of the correction threshold did not deteriorate the accuracy of the off‐line setup correction compared to the NAL protocol. The combination of the fixed vertical couch position protocol, for correction of the anteroposterior setup error, and the fixed‐action–level protocol with 2.5 mm correction threshold, for correction of the mediolateral and the superior–inferior setup errors, was proved to provide adequate and comparable patient setup accuracy in WBRT and WBRT with additional LN irradiation. PACS numbers: 87.53.Kn, 87.57.‐s

  7. Evaluation of joint position sense measured by inversion angle replication error in patients with an osteochondral lesion of the talus.

    PubMed

    Nakasa, Tomoyuki; Adachi, Nobuo; Shibuya, Hayatoshi; Okuhara, Atsushi; Ochi, Mitsuo

    2013-01-01

    The etiology of the osteochondral lesion of the talar dome (OLT) remains unclear. A joint position sense deficit of the ankle is reported to be a possible cause of ankle disorder. Repeated contact of the articular surface of the talar dome with the plafond during inversion might be a cause of OLT. The aim of the present study was to evaluate the joint position sense deficit by measuring the replication error of the inversion angle in patients with OLT. The replication error, which is the difference between the index angle and replication angle in inversion, was measured in 15 patients with OLT. The replication error in 15 healthy volunteers was evaluated as a control group. The side to side differences of the replication errors between the patients with OLT and healthy volunteers and the replication errors in each angle between the involved and uninvolved ankle in the patients with OLT were investigated. Finally, the side to side differences of the replication errors between the patients with OLT with a traumatic and nontraumatic history were compared. The side to side difference in the patients with OLT (1.3° ± 0.2°) was significantly greater than that in the healthy subjects (0.4° ± 0.7°) (p ≤ .05). Significant differences were found between the involved and uninvolved sides at 10°, 15°, 20°, and 25° in the patients with OLT. No significant difference (p > .05) was found between the patients with traumatic and nontraumatic OLT. The present study found that the patients with OLT have a joint position sense deficit during inversion movement, regardless of a traumatic history. Although various factors for the etiology of OLT have been reported, the joint position sense deficit in inversion might be a cause of OLT. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Kinematic Model-Based Pedestrian Dead Reckoning for Heading Correction and Lower Body Motion Tracking.

    PubMed

    Lee, Min Su; Ju, Hojin; Song, Jin Woo; Park, Chan Gook

    2015-11-06

    In this paper, we present a method for finding the enhanced heading and position of pedestrians by fusing the Zero velocity UPdaTe (ZUPT)-based pedestrian dead reckoning (PDR) and the kinematic constraints of the lower human body. ZUPT is a well known algorithm for PDR, and provides a sufficiently accurate position solution for short term periods, but it cannot guarantee a stable and reliable heading because it suffers from magnetic disturbance in determining heading angles, which degrades the overall position accuracy as time passes. The basic idea of the proposed algorithm is integrating the left and right foot positions obtained by ZUPTs with the heading and position information from an IMU mounted on the waist. To integrate this information, a kinematic model of the lower human body, which is calculated by using orientation sensors mounted on both thighs and calves, is adopted. We note that the position of the left and right feet cannot be apart because of the kinematic constraints of the body, so the kinematic model generates new measurements for the waist position. The Extended Kalman Filter (EKF) on the waist data that estimates and corrects error states uses these measurements and magnetic heading measurements, which enhances the heading accuracy. The updated position information is fed into the foot mounted sensors, and reupdate processes are performed to correct the position error of each foot. The proposed update-reupdate technique consequently ensures improved observability of error states and position accuracy. Moreover, the proposed method provides all the information about the lower human body, so that it can be applied more effectively to motion tracking. The effectiveness of the proposed algorithm is verified via experimental results, which show that a 1.25% Return Position Error (RPE) with respect to walking distance is achieved.

  9. Hyperbolic Positioning with Antenna Arrays and Multi-Channel Pseudolite for Indoor Localization

    PubMed Central

    Fujii, Kenjirou; Sakamoto, Yoshihiro; Wang, Wei; Arie, Hiroaki; Schmitz, Alexander; Sugano, Shigeki

    2015-01-01

    A hyperbolic positioning method with antenna arrays consisting of proximately-located antennas and a multi-channel pseudolite is proposed in order to overcome the problems of indoor positioning with conventional pseudolites (ground-based GPS transmitters). A two-dimensional positioning experiment using actual devices is conducted. The experimental result shows that the positioning accuracy varies centimeter- to meter-level according to the geometric relation between the pseudolite antennas and the receiver. It also shows that the bias error of the carrier-phase difference observables is more serious than their random error. Based on the size of the bias error of carrier-phase difference that is inverse-calculated from the experimental result, three-dimensional positioning performance is evaluated by computer simulation. In addition, in the three-dimensional positioning scenario, an initial value convergence analysis of the non-linear least squares is conducted. Its result shows that initial values that can converge to a right position exist at least under the proposed antenna setup. The simulated values and evaluation methods introduced in this work can be applied to various antenna setups; therefore, by using them, positioning performance can be predicted in advance of installing an actual system. PMID:26437405

  10. SU-E-J-94: Positioning Errors Resulting From Using Bony Anatomy Alignment for Treating SBRT Lung Tumor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frame, C; Ding, G

    Purpose: To quantify patient setups errors based on bony anatomy registration rather than 3D tumor alignment for SBRT lung treatments. Method: A retrospective study was performed for patients treated with lung SBRT and imaged with kV cone beam computed tomography (kV-CBCT) image-guidance. Daily CBCT images were registered to treatment planning CTs based on bony anatomy alignment and then inter-fraction tumor movement was evaluated by comparing shift in the tumor center in the medial-lateral, anterior-posterior, and superior-inferior directions. The PTV V100% was evaluated for each patient based on the average daily tumor displacement to assess the impact of the positioning errormore » on the target coverage when the registrations were based on bony anatomy. Of the 35 patients studied, 15 were free-breathing treatments, 10 used abdominal compression with a stereotactic body frame, and the remaining 10 were performed with BodyFIX vacuum bags. Results: For free-breathing treatments, the range of tumor displacement error is between 1–6 mm in the medial-lateral, 1–13 mm in the anterior-posterior, and 1–7 mm in the superior-inferior directions. These positioning errors lead to 6–22% underdose coverage for PTV - V100% . Patients treated with abdominal compression immobilization showed positional errors of 0–4mm mediallaterally, 0–3mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% underdose ranging between 6–17%. For patients immobilized with the vacuum bags, the positional errors were found to be 0–1 mm medial-laterally, 0–1mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% under dose ranging between 5–6% only. Conclusion: It is necessary to align the tumor target by using 3D image guidance to ensure adequate tumor coverage before performing SBRT lung treatments. The BodyFIX vacuum bag immobilization method has the least positioning errors among the three methods studied when bony anatomy is used for registration.« less

  11. Effect of ephemeris errors on the accuracy of the computation of the tangent point altitude of a solar scanning ray as measured by the SAGE 1 and 2 instruments

    NASA Technical Reports Server (NTRS)

    Buglia, James J.

    1989-01-01

    An analysis was made of the error in the minimum altitude of a geometric ray from an orbiting spacecraft to the Sun. The sunrise and sunset errors are highly correlated and are opposite in sign. With the ephemeris generated for the SAGE 1 instrument data reduction, these errors can be as large as 200 to 350 meters (1 sigma) after 7 days of orbit propagation. The bulk of this error results from errors in the position of the orbiting spacecraft rather than errors in computing the position of the Sun. These errors, in turn, result from the discontinuities in the ephemeris tapes resulting from the orbital determination process. Data taken from the end of the definitive ephemeris tape are used to generate the predict data for the time interval covered by the next arc of the orbit determination process. The predicted data are then updated by using the tracking data. The growth of these errors is very nearly linear, with a slight nonlinearity caused by the beta angle. An approximate analytic method is given, which predicts the magnitude of the errors and their growth in time with reasonable fidelity.

  12. Nurses' attitudes and perceived barriers to the reporting of medication administration errors.

    PubMed

    Yung, Hai-Peng; Yu, Shu; Chu, Chi; Hou, I-Ching; Tang, Fu-In

    2016-07-01

    (1) To explore the attitudes and perceived barriers to reporting medication administration errors and (2) to understand the characteristics of - and nurses' feelings - about error reports. Under-reporting of medication administration errors is a global concern related to the safety of patient care. Understanding nurses' attitudes and perceived barriers to error reporting is the initial step to increasing the reporting rate. A cross-sectional, descriptive survey with a self-administered questionnaire was completed by the nurses of a medical centre hospital in Taiwan. A total of 306 nurses participated in the study. Nurses' attitudes towards medication administration error reporting were inclined towards positive. The major perceived barrier was fear of the consequences after reporting. The results demonstrated that 88.9% of medication administration errors were reported orally, whereas 19.0% were reported through the hospital internet system. Self-recrimination was the common feeling of nurses after the commission of an medication administration error. Even if hospital management encourages errors to be reported without recrimination, nurses' attitudes toward medication administration error reporting are not very positive and fear is the most prominent barrier contributing to underreporting. Nursing managers should establish anonymous reporting systems and counselling classes to create a secure atmosphere to reduce nurses' fear and provide incentives to encourage reporting. © 2016 John Wiley & Sons Ltd.

  13. Historical shoreline mapping (I): improving techniques and reducing positioning errors

    USGS Publications Warehouse

    Thieler, E. Robert; Danforth, William W.

    1994-01-01

    A critical need exists among coastal researchers and policy-makers for a precise method to obtain shoreline positions from historical maps and aerial photographs. A number of methods that vary widely in approach and accuracy have been developed to meet this need. None of the existing methods, however, address the entire range of cartographic and photogrammetric techniques required for accurate coastal mapping. Thus, their application to many typical shoreline mapping problems is limited. In addition, no shoreline mapping technique provides an adequate basis for quantifying the many errors inherent in shoreline mapping using maps and air photos. As a result, current assessments of errors in air photo mapping techniques generally (and falsely) assume that errors in shoreline positions are represented by the sum of a series of worst-case assumptions about digitizer operator resolution and ground control accuracy. These assessments also ignore altogether other errors that commonly approach ground distances of 10 m. This paper provides a conceptual and analytical framework for improved methods of extracting geographic data from maps and aerial photographs. We also present a new approach to shoreline mapping using air photos that revises and extends a number of photogrammetric techniques. These techniques include (1) developing spatially and temporally overlapping control networks for large groups of photos; (2) digitizing air photos for use in shoreline mapping; (3) preprocessing digitized photos to remove lens distortion and film deformation effects; (4) simultaneous aerotriangulation of large groups of spatially and temporally overlapping photos; and (5) using a single-ray intersection technique to determine geographic shoreline coordinates and express the horizontal and vertical error associated with a given digitized shoreline. As long as historical maps and air photos are used in studies of shoreline change, there will be a considerable amount of error (on the order of several meters) present in shoreline position and rate-of- change calculations. The techniques presented in this paper, however, provide a means to reduce and quantify these errors so that realistic assessments of the technological noise (as opposed to geological noise) in geographic shoreline positions can be made.

  14. Mapping intended spinal site of care from the upright to prone position: an interexaminer reliability study.

    PubMed

    Cooperstein, Robert; Young, Morgan

    2014-01-01

    Upright examination procedures like radiology, thermography, manual muscle testing, and spinal motion palpation may lead to spinal interventions with the patient prone. The reliability and accuracy of mapping upright examination findings to the prone position is unknown. This study had 2 primary goals: (1) investigate how erroneous spine-scapular landmark associations may lead to errors in treating and charting spine levels; and (2) study the interexaminer reliability of a novel method for mapping upright spinal sites to the prone position. Experiment 1 was a thought experiment exploring the consequences of depending on the erroneous landmark association of the inferior scapular tip with the T7 spinous process upright and T6 spinous process prone (relatively recent studies suggest these levels are T8 and T9, respectively). This allowed deduction of targeting and charting errors. In experiment 2, 10 examiners (2 experienced, 8 novice) used an index finger to maintain contact with a mid-thoracic spinous process as each of 2 participants slowly moved from the upright to the prone position. Interexaminer reliability was assessed by computing Intraclass Correlation Coefficient, standard error of the mean, root mean squared error, and the absolute value of the mean difference for each examiner from the 10 examiner mean for each of the 2 participants. The thought experiment suggesting that using the (inaccurate) scapular tip landmark rule would result in a 3 level targeting and charting error when radiological findings are mapped to the prone position. Physical upright exam procedures like motion palpation would result in a 2 level targeting error for intervention, and a 3 level error for charting. The reliability experiment showed examiners accurately maintained contact with the same thoracic spinous process as the participant went from upright to prone, ICC (2,1) = 0.83. As manual therapists, the authors have emphasized how targeting errors may impact upon manual care of the spine. Practitioners in other fields that need to accurately locate spinal levels, such as acupuncture and anesthesiology, would also be expected to draw important conclusions from these findings.

  15. Mapping intended spinal site of care from the upright to prone position: an interexaminer reliability study

    PubMed Central

    2014-01-01

    Background Upright examination procedures like radiology, thermography, manual muscle testing, and spinal motion palpation may lead to spinal interventions with the patient prone. The reliability and accuracy of mapping upright examination findings to the prone position is unknown. This study had 2 primary goals: (1) investigate how erroneous spine-scapular landmark associations may lead to errors in treating and charting spine levels; and (2) study the interexaminer reliability of a novel method for mapping upright spinal sites to the prone position. Methods Experiment 1 was a thought experiment exploring the consequences of depending on the erroneous landmark association of the inferior scapular tip with the T7 spinous process upright and T6 spinous process prone (relatively recent studies suggest these levels are T8 and T9, respectively). This allowed deduction of targeting and charting errors. In experiment 2, 10 examiners (2 experienced, 8 novice) used an index finger to maintain contact with a mid-thoracic spinous process as each of 2 participants slowly moved from the upright to the prone position. Interexaminer reliability was assessed by computing Intraclass Correlation Coefficient, standard error of the mean, root mean squared error, and the absolute value of the mean difference for each examiner from the 10 examiner mean for each of the 2 participants. Results The thought experiment suggesting that using the (inaccurate) scapular tip landmark rule would result in a 3 level targeting and charting error when radiological findings are mapped to the prone position. Physical upright exam procedures like motion palpation would result in a 2 level targeting error for intervention, and a 3 level error for charting. The reliability experiment showed examiners accurately maintained contact with the same thoracic spinous process as the participant went from upright to prone, ICC (2,1) = 0.83. Conclusions As manual therapists, the authors have emphasized how targeting errors may impact upon manual care of the spine. Practitioners in other fields that need to accurately locate spinal levels, such as acupuncture and anesthesiology, would also be expected to draw important conclusions from these findings. PMID:24904747

  16. Observations of geographically correlated orbit errors for TOPEX/Poseidon using the global positioning system

    NASA Technical Reports Server (NTRS)

    Christensen, E. J.; Haines, B. J.; Mccoll, K. C.; Nerem, R. S.

    1994-01-01

    We have compared Global Positioning System (GPS)-based dynamic and reduced-dynamic TOPEX/Poseidon orbits over three 10-day repeat cycles of the ground-track. The results suggest that the prelaunch joint gravity model (JGM-1) introduces geographically correlated errors (GCEs) which have a strong meridional dependence. The global distribution and magnitude of these GCEs are consistent with a prelaunch covariance analysis, with estimated and predicted global rms error statistics of 2.3 and 2.4 cm rms, respectively. Repeating the analysis with the post-launch joint gravity model (JGM-2) suggests that a portion of the meridional dependence observed in JGM-1 still remains, with global rms error of 1.2 cm.

  17. Research into Kinect/Inertial Measurement Units Based on Indoor Robots.

    PubMed

    Li, Huixia; Wen, Xi; Guo, Hang; Yu, Min

    2018-03-12

    As indoor mobile navigation suffers from low positioning accuracy and accumulation error, we carried out research into an integrated location system for a robot based on Kinect and an Inertial Measurement Unit (IMU). In this paper, the close-range stereo images are used to calculate the attitude information and the translation amount of the adjacent positions of the robot by means of the absolute orientation algorithm, for improving the calculation accuracy of the robot's movement. Relying on the Kinect visual measurement and the strap-down IMU devices, we also use Kalman filtering to obtain the errors of the position and attitude outputs, in order to seek the optimal estimation and correct the errors. Experimental results show that the proposed method is able to improve the positioning accuracy and stability of the indoor mobile robot.

  18. A method for optical ground station reduce alignment error in satellite-ground quantum experiments

    NASA Astrophysics Data System (ADS)

    He, Dong; Wang, Qiang; Zhou, Jian-Wei; Song, Zhi-Jun; Zhong, Dai-Jun; Jiang, Yu; Liu, Wan-Sheng; Huang, Yong-Mei

    2018-03-01

    A satellite dedicated for quantum science experiments, has been developed and successfully launched from Jiuquan, China, on August 16, 2016. Two new optical ground stations (OGSs) were built to cooperate with the satellite to complete satellite-ground quantum experiments. OGS corrected its pointing direction by satellite trajectory error to coarse tracking system and uplink beacon sight, therefore fine tracking CCD and uplink beacon optical axis alignment accuracy was to ensure that beacon could cover the quantum satellite in all time when it passed the OGSs. Unfortunately, when we tested specifications of the OGSs, due to the coarse tracking optical system was commercial telescopes, the change of position of the target in the coarse CCD was up to 600μrad along with the change of elevation angle. In this paper, a method of reduce alignment error between beacon beam and fine tracking CCD is proposed. Firstly, OGS fitted the curve of target positions in coarse CCD along with the change of elevation angle. Secondly, OGS fitted the curve of hexapod secondary mirror positions along with the change of elevation angle. Thirdly, when tracking satellite, the fine tracking error unloaded on the real-time zero point position of coarse CCD which computed by the firstly calibration data. Simultaneously the positions of the hexapod secondary mirror were adjusted by the secondly calibration data. Finally the experiment result is proposed. Results show that the alignment error is less than 50μrad.

  19. Online Error Reporting for Managing Quality Control Within Radiology.

    PubMed

    Golnari, Pedram; Forsberg, Daniel; Rosipko, Beverly; Sunshine, Jeffrey L

    2016-06-01

    Information technology systems within health care, such as picture archiving and communication system (PACS) in radiology, can have a positive impact on production but can also risk compromising quality. The widespread use of PACS has removed the previous feedback loop between radiologists and technologists. Instead of direct communication of quality discrepancies found for an examination, the radiologist submitted a paper-based quality-control report. A web-based issue-reporting tool can help restore some of the feedback loop and also provide possibilities for more detailed analysis of submitted errors. The purpose of this study was to evaluate the hypothesis that data from use of an online error reporting software for quality control can focus our efforts within our department. For the 372,258 radiologic examinations conducted during the 6-month period study, 930 errors (390 exam protocol, 390 exam validation, and 150 exam technique) were submitted, corresponding to an error rate of 0.25 %. Within the category exam protocol, technologist documentation had the highest number of submitted errors in ultrasonography (77 errors [44 %]), while imaging protocol errors were the highest subtype error for computed tomography modality (35 errors [18 %]). Positioning and incorrect accession had the highest errors in the exam technique and exam validation error category, respectively, for nearly all of the modalities. An error rate less than 1 % could signify a system with a very high quality; however, a more likely explanation is that not all errors were detected or reported. Furthermore, staff reception of the error reporting system could also affect the reporting rate.

  20. From the macro to the micro: a geographic examination of the community context and early adolescent problem behaviors.

    PubMed

    Chilenski, Sarah M

    2011-12-01

    This study examined how multiple dimensions and levels of the community context associated with early adolescent problem behaviors in rural communities. Four thousand, five hundred and nine eighth-grade students in 28 rural and small town school districts in two states participated in surveys regarding substance use and delinquency in 2005. Locations of alcohol retailers, tobacco retailers, youth-serving organizations, and student residences were geocoded. Associations of the number of proximal alcohol and tobacco retailers, and youth-serving organizations with an early-adolescent problem behavior index were tested in Nonlinear Mixed Models that controlled for multiple district-level and individual characteristics. Multi-level model results demonstrated that the number of alcohol and tobacco retail locations within a one-mile radius of each adolescent's home positively associated with student-reported problem behaviors above and beyond the influence of school district and individual characteristics. Results suggest that the proximal community context added significantly to the district context when understanding the occurrence of early adolescent problem behaviors. Recognizing this variability in geographically determined risk within a community will likely enhance the effectiveness of community prevention activities.

  1. Ethnic density and depressive symptoms among African Americans: threshold and differential effects across social and demographic subgroups.

    PubMed

    Bécares, Laia; Nazroo, James; Jackson, James

    2014-12-01

    We examined the association between Black ethnic density and depressive symptoms among African Americans. We sought to ascertain whether a threshold exists in the association between Black ethnic density and an important mental health outcome, and to identify differential effects of this association across social, economic, and demographic subpopulations. We analyzed the African American sample (n = 3570) from the National Survey of American Life, which we geocoded to the 2000 US Census. We determined the threshold with a multivariable regression spline model. We examined differential effects of ethnic density with random-effects multilevel linear regressions stratified by sociodemographic characteristics. The protective association between Black ethnic density and depressive symptoms changed direction, becoming a detrimental effect, when ethnic density reached 85%. Black ethnic density was protective for lower socioeconomic positions and detrimental for the better-off categories. The masking effects of area deprivation were stronger in the highest levels of Black ethnic density. Addressing racism, racial discrimination, economic deprivation, and poor services-the main drivers differentiating ethnic density from residential segregation-will help to ensure that the racial/ethnic composition of a neighborhood is not a risk factor for poor mental health.

  2. Ethnic Density and Depressive Symptoms Among African Americans: Threshold and Differential Effects Across Social and Demographic Subgroups

    PubMed Central

    Nazroo, James; Jackson, James

    2014-01-01

    Objectives. We examined the association between Black ethnic density and depressive symptoms among African Americans. We sought to ascertain whether a threshold exists in the association between Black ethnic density and an important mental health outcome, and to identify differential effects of this association across social, economic, and demographic subpopulations. Methods. We analyzed the African American sample (n = 3570) from the National Survey of American Life, which we geocoded to the 2000 US Census. We determined the threshold with a multivariable regression spline model. We examined differential effects of ethnic density with random-effects multilevel linear regressions stratified by sociodemographic characteristics. Results. The protective association between Black ethnic density and depressive symptoms changed direction, becoming a detrimental effect, when ethnic density reached 85%. Black ethnic density was protective for lower socioeconomic positions and detrimental for the better-off categories. The masking effects of area deprivation were stronger in the highest levels of Black ethnic density. Conclusions. Addressing racism, racial discrimination, economic deprivation, and poor services—the main drivers differentiating ethnic density from residential segregation—will help to ensure that the racial/ethnic composition of a neighborhood is not a risk factor for poor mental health. PMID:25322307

  3. Socioeconomic gradients in sexually transmitted diseases: a geographic information system-based analysis of poverty, race/ethnicity, and gonorrhea rates in California, 2004-2006.

    PubMed

    Springer, Yuri P; Samuel, Michael C; Bolan, Gail

    2010-06-01

    We quantified the relationship between gonorrheal infection rates in California and a measure of poverty status and investigated how this relationship and the spatial dispersion of cases varied among the 4 dominant racial/ethnic groups in the state. We geocoded gonorrhea cases reported in California between 2004 and 2006, and estimated the poverty status of each case by using the percentage of residents living below poverty in the census tract of residence. We calculated infection rates for African American, Asian, Hispanic, and White cases in each of 4 poverty strata. We mapped cases to visualize the patterns of spatial dispersion associated with each race/ethnicity-poverty combination. There was a strong positive relationship between poverty and infection, but racial/ethnic disparities in infection, driven by a disproportionate level of gonorrhea among African Americans, eclipsed this differential. The degree of spatial aggregation varied substantially among groups and was especially pronounced for African Americans with gonorrhea in the highest poverty category. Prevention efforts should target low-income neighborhood "hot spots" to reach the largest numbers of cases, particularly among African Americans.

  4. From the macro to the micro: A geographic examination of the community context and early adolescent problem behaviors

    PubMed Central

    Chilenski, Sarah M.

    2013-01-01

    This study examined how multiple dimensions and levels of the community context associated with early adolescent problem behaviors in rural communities. Four thousand, five hundred and nine eighth-grade students in 28 rural and small town school districts in two states participated in surveys regarding substance use and delinquency in 2005. Locations of alcohol retailers, tobacco retailers, youth-serving organizations, and student residences were geocoded. Associations of the number of proximal alcohol and tobacco retailers, and youth-serving organizations with an early-adolescent problem behavior index were tested in Nonlinear Mixed Models that controlled for multiple district-level and individual characteristics. Multi-level model results demonstrated that the number of alcohol and tobacco retail locations within a one-mile radius of each adolescent’s home positively associated with student-reported problem behaviors above and beyond the influence of school district and individual characteristics. Results suggest that the proximal community context added significantly to the district context when understanding the occurrence of early adolescent problem behaviors. Recognizing this variability in geographically determined risk within a community will likely enhance the effectiveness of community prevention activities. PMID:21336674

  5. SU-F-P-18: Development of the Technical Training System for Patient Set-Up Considering Rotational Correction in the Virtual Environment Using Three-Dimensional Computer Graphic Engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Imura, K; Fujibuchi, T; Hirata, H

    Purpose: Patient set-up skills in radiotherapy treatment room have a great influence on treatment effect for image guided radiotherapy. In this study, we have developed the training system for improving practical set-up skills considering rotational correction in the virtual environment away from the pressure of actual treatment room by using three-dimensional computer graphic (3DCG) engine. Methods: The treatment room for external beam radiotherapy was reproduced in the virtual environment by using 3DCG engine (Unity). The viewpoints to perform patient set-up in the virtual treatment room were arranged in both sides of the virtual operable treatment couch to assume actual performancemore » by two clinical staffs. The position errors to mechanical isocenter considering alignment between skin marker and laser on the virtual patient model were displayed by utilizing numerical values expressed in SI units and the directions of arrow marks. The rotational errors calculated with a point on the virtual body axis as the center of each rotation axis for the virtual environment were corrected by adjusting rotational position of the body phantom wound the belt with gyroscope preparing on table in a real space. These rotational errors were evaluated by describing vector outer product operations and trigonometric functions in the script for patient set-up technique. Results: The viewpoints in the virtual environment allowed individual user to visually recognize the position discrepancy to mechanical isocenter until eliminating the positional errors of several millimeters. The rotational errors between the two points calculated with the center point could be efficiently corrected to display the minimum technique mathematically by utilizing the script. Conclusion: By utilizing the script to correct the rotational errors as well as accurate positional recognition for patient set-up technique, the training system developed for improving patient set-up skills enabled individual user to indicate efficient positional correction methods easily.« less

  6. Achieving unequal error protection with convolutional codes

    NASA Technical Reports Server (NTRS)

    Mills, D. G.; Costello, D. J., Jr.; Palazzo, R., Jr.

    1994-01-01

    This paper examines the unequal error protection capabilities of convolutional codes. Both time-invariant and periodically time-varying convolutional encoders are examined. The effective free distance vector is defined and is shown to be useful in determining the unequal error protection (UEP) capabilities of convolutional codes. A modified transfer function is used to determine an upper bound on the bit error probabilities for individual input bit positions in a convolutional encoder. The bound is heavily dependent on the individual effective free distance of the input bit position. A bound relating two individual effective free distances is presented. The bound is a useful tool in determining the maximum possible disparity in individual effective free distances of encoders of specified rate and memory distribution. The unequal error protection capabilities of convolutional encoders of several rates and memory distributions are determined and discussed.

  7. Influence of ECG measurement accuracy on ECG diagnostic statements.

    PubMed

    Zywietz, C; Celikag, D; Joseph, G

    1996-01-01

    Computer analysis of electrocardiograms (ECGs) provides a large amount of ECG measurement data, which may be used for diagnostic classification and storage in ECG databases. Until now, neither error limits for ECG measurements have been specified nor has their influence on diagnostic statements been systematically investigated. An analytical method is presented to estimate the influence of measurement errors on the accuracy of diagnostic ECG statements. Systematic (offset) errors will usually result in an increase of false positive or false negative statements since they cause a shift of the working point on the receiver operating characteristics curve. Measurement error dispersion broadens the distribution function of discriminative measurement parameters and, therefore, usually increases the overlap between discriminative parameters. This results in a flattening of the receiver operating characteristics curve and an increase of false positive and false negative classifications. The method developed has been applied to ECG conduction defect diagnoses by using the proposed International Electrotechnical Commission's interval measurement tolerance limits. These limits appear too large because more than 30% of false positive atrial conduction defect statements and 10-18% of false intraventricular conduction defect statements could be expected due to tolerated measurement errors. To assure long-term usability of ECG measurement databases, it is recommended that systems provide its error tolerance limits obtained on a defined test set.

  8. Analysis of error-correction constraints in an optical disk.

    PubMed

    Roberts, J D; Ryley, A; Jones, D M; Burke, D

    1996-07-10

    The compact disk read-only memory (CD-ROM) is a mature storage medium with complex error control. It comprises four levels of Reed Solomon codes allied to a sequence of sophisticated interleaving strategies and 8:14 modulation coding. New storage media are being developed and introduced that place still further demands on signal processing for error correction. It is therefore appropriate to explore thoroughly the limit of existing strategies to assess future requirements. We describe a simulation of all stages of the CD-ROM coding, modulation, and decoding. The results of decoding the burst error of a prescribed number of modulation bits are discussed in detail. Measures of residual uncorrected error within a sector are displayed by C1, C2, P, and Q error counts and by the status of the final cyclic redundancy check (CRC). Where each data sector is encoded separately, it is shown that error-correction performance against burst errors depends critically on the position of the burst within a sector. The C1 error measures the burst length, whereas C2 errors reflect the burst position. The performance of Reed Solomon product codes is shown by the P and Q statistics. It is shown that synchronization loss is critical near the limits of error correction. An example is given of miscorrection that is identified by the CRC check.

  9. Analysis of error-correction constraints in an optical disk

    NASA Astrophysics Data System (ADS)

    Roberts, Jonathan D.; Ryley, Alan; Jones, David M.; Burke, David

    1996-07-01

    The compact disk read-only memory (CD-ROM) is a mature storage medium with complex error control. It comprises four levels of Reed Solomon codes allied to a sequence of sophisticated interleaving strategies and 8:14 modulation coding. New storage media are being developed and introduced that place still further demands on signal processing for error correction. It is therefore appropriate to explore thoroughly the limit of existing strategies to assess future requirements. We describe a simulation of all stages of the CD-ROM coding, modulation, and decoding. The results of decoding the burst error of a prescribed number of modulation bits are discussed in detail. Measures of residual uncorrected error within a sector are displayed by C1, C2, P, and Q error counts and by the status of the final cyclic redundancy check (CRC). Where each data sector is encoded separately, it is shown that error-correction performance against burst errors depends critically on the position of the burst within a sector. The C1 error measures the burst length, whereas C2 errors reflect the burst position. The performance of Reed Solomon product codes is shown by the P and Q statistics. It is shown that synchronization loss is critical near the limits of error correction. An example is given of miscorrection that is identified by the CRC check.

  10. Improvement of tsunami detection in timeseries data of GPS buoys with the Continuous Wavelet Transform

    NASA Astrophysics Data System (ADS)

    Chida, Y.; Takagawa, T.

    2017-12-01

    The observation data of GPS buoys which are installed in the offshore of Japan are used for monitoring not only waves but also tsunamis in Japan. The real-time data was successfully used to upgrade the tsunami warnings just after the 2011 Tohoku earthquake. Huge tsunamis can be easily detected because the signal-noise ratio is high enough, but moderate tsunami is not. GPS data sometimes include the error waveforms like tsunamis because of changing accuracy by the number and the position of GPS satellites. To distinguish the true tsunami waveforms from pseudo-tsunami ones is important for tsunami detection. In this research, a method to reduce misdetections of tsunami in the observation data of GPS buoys and to increase the efficiency of tsunami detection was developed.Firstly, the error waveforms were extracted by using the indexes of position dilution of precision, reliability of GPS satellite positioning and satellite number for calculation. Then, the output from this procedure was used for the Continuous Wavelet Transform (CWT) to analyze the time-frequency characteristics of error waveforms and real tsunami waveforms.We found that the error waveforms tended to appear when the accuracy of GPS buoys positioning was low. By extracting these waveforms, it was possible to decrease about 43% error waveforms without the reduction of the tsunami detection rate. Moreover, we found that the amplitudes of power spectra obtained from the error waveforms and real tsunamis were similar in the component of long period (4-65 minutes), on the other hand, the amplitude in the component of short period (< 1 minute) obtained from the error waveforms was significantly larger than that of the real tsunami waveforms. By thresholding of the short-period component, further extraction of error waveforms became possible without a significant reduction of tsunami detection rate.

  11. Predictive and Feedback Performance Errors are Signaled in the Simple Spike Discharge of Individual Purkinje Cells

    PubMed Central

    Popa, Laurentiu S.; Hewitt, Angela L.; Ebner, Timothy J.

    2012-01-01

    The cerebellum has been implicated in processing motor errors required for online control of movement and motor learning. The dominant view is that Purkinje cell complex spike discharge signals motor errors. This study investigated whether errors are encoded in the simple spike discharge of Purkinje cells in monkeys trained to manually track a pseudo-randomly moving target. Four task error signals were evaluated based on cursor movement relative to target movement. Linear regression analyses based on firing residuals ensured that the modulation with a specific error parameter was independent of the other error parameters and kinematics. The results demonstrate that simple spike firing in lobules IV–VI is significantly correlated with position, distance and directional errors. Independent of the error signals, the same Purkinje cells encode kinematics. The strongest error modulation occurs at feedback timing. However, in 72% of cells at least one of the R2 temporal profiles resulting from regressing firing with individual errors exhibit two peak R2 values. For these bimodal profiles, the first peak is at a negative τ (lead) and a second peak at a positive τ (lag), implying that Purkinje cells encode both prediction and feedback about an error. For the majority of the bimodal profiles, the signs of the regression coefficients or preferred directions reverse at the times of the peaks. The sign reversal results in opposing simple spike modulation for the predictive and feedback components. Dual error representations may provide the signals needed to generate sensory prediction errors used to update a forward internal model. PMID:23115173

  12. Long-term neuromuscular training and ankle joint position sense.

    PubMed

    Kynsburg, A; Pánics, G; Halasi, T

    2010-06-01

    Preventive effect of proprioceptive training is proven by decreasing injury incidence, but its proprioceptive mechanism is not. Major hypothesis: the training has a positive long-term effect on ankle joint position sense in athletes of a high-risk sport (handball). Ten elite-level female handball-players represented the intervention group (training-group), 10 healthy athletes of other sports formed the control-group. Proprioceptive training was incorporated into the regular training regimen of the training-group. Ankle joint position sense function was measured with the "slope-box" test, first described by Robbins et al. Testing was performed one day before the intervention and 20 months later. Mean absolute estimate errors were processed for statistical analysis. Proprioceptive sensory function improved regarding all four directions with a high significance (p<0.0001; avg. mean estimate error improvement: 1.77 degrees). This was also highly significant (p< or =0.0002) in each single directions, with avg. mean estimate error improvement between 1.59 degrees (posterior) and 2.03 degrees (anterior). Mean absolute estimate errors at follow-up (2.24 degrees +/-0.88 degrees) were significantly lower than in uninjured controls (3.29 degrees +/-1.15 degrees) (p<0.0001). Long-term neuromuscular training has improved ankle joint position sense function in the investigated athletes. This joint position sense improvement can be one of the explanations for injury rate reduction effect of neuromuscular training.

  13. An RFID Indoor Positioning Algorithm Based on Bayesian Probability and K-Nearest Neighbor.

    PubMed

    Xu, He; Ding, Ye; Li, Peng; Wang, Ruchuan; Li, Yizhu

    2017-08-05

    The Global Positioning System (GPS) is widely used in outdoor environmental positioning. However, GPS cannot support indoor positioning because there is no signal for positioning in an indoor environment. Nowadays, there are many situations which require indoor positioning, such as searching for a book in a library, looking for luggage in an airport, emergence navigation for fire alarms, robot location, etc. Many technologies, such as ultrasonic, sensors, Bluetooth, WiFi, magnetic field, Radio Frequency Identification (RFID), etc., are used to perform indoor positioning. Compared with other technologies, RFID used in indoor positioning is more cost and energy efficient. The Traditional RFID indoor positioning algorithm LANDMARC utilizes a Received Signal Strength (RSS) indicator to track objects. However, the RSS value is easily affected by environmental noise and other interference. In this paper, our purpose is to reduce the location fluctuation and error caused by multipath and environmental interference in LANDMARC. We propose a novel indoor positioning algorithm based on Bayesian probability and K -Nearest Neighbor (BKNN). The experimental results show that the Gaussian filter can filter some abnormal RSS values. The proposed BKNN algorithm has the smallest location error compared with the Gaussian-based algorithm, LANDMARC and an improved KNN algorithm. The average error in location estimation is about 15 cm using our method.

  14. Integrity monitoring of vehicle positioning in urban environment using RTK-GNSS, IMU and speedometer

    NASA Astrophysics Data System (ADS)

    El-Mowafy, Ahmed; Kubo, Nobuaki

    2017-05-01

    Continuous and trustworthy positioning is a critical capability for advanced driver assistance systems (ADAS). To achieve continuous positioning, methods such as global navigation satellite systems real-time kinematic (RTK), Doppler-based positioning, and positioning using low-cost inertial measurement unit (IMU) with car speedometer data are combined in this study. To ensure reliable positioning, the system should have integrity monitoring above a certain level, such as 99%. Achieving this level when combining different types of measurements that have different characteristics and different types of errors is a challenge. In this study, a novel integrity monitoring approach is presented for the proposed integrated system. A threat model of the measurements of the system components is discussed, which includes both the nominal performance and possible fault modes. A new protection level is presented to bound the maximum directional position error. The proposed approach was evaluated through a kinematic test in an urban area in Japan with a focus on horizontal positioning. Test results show that by integrating RTK, Doppler with IMU/speedometer, 100% positioning availability was achieved. The integrity monitoring availability was assessed and found to meet the target value where the position errors were bounded by the protection level, which was also less than an alert level, indicating the effectiveness of the proposed approach.

  15. Children and Adults Both See "Pirates" in "Parties": Letter-Position Effects for Developing Readers and Skilled Adult Readers

    ERIC Educational Resources Information Center

    Paterson, Kevin B.; Read, Josephine; McGowan, Victoria A.; Jordan, Timothy R.

    2015-01-01

    Developing readers often make anagrammatical errors (e.g. misreading pirates as parties), suggesting they use letter position flexibly during word recognition. However, while it is widely assumed that the occurrence of these errors decreases with increases in reading skill, empirical evidence to support this distinction is lacking. Accordingly, we…

  16. Measurement of electromagnetic tracking error in a navigated breast surgery setup

    NASA Astrophysics Data System (ADS)

    Harish, Vinyas; Baksh, Aidan; Ungi, Tamas; Lasso, Andras; Baum, Zachary; Gauvin, Gabrielle; Engel, Jay; Rudan, John; Fichtinger, Gabor

    2016-03-01

    PURPOSE: The measurement of tracking error is crucial to ensure the safety and feasibility of electromagnetically tracked, image-guided procedures. Measurement should occur in a clinical environment because electromagnetic field distortion depends on positioning relative to the field generator and metal objects. However, we could not find an accessible and open-source system for calibration, error measurement, and visualization. We developed such a system and tested it in a navigated breast surgery setup. METHODS: A pointer tool was designed for concurrent electromagnetic and optical tracking. Software modules were developed for automatic calibration of the measurement system, real-time error visualization, and analysis. The system was taken to an operating room to test for field distortion in a navigated breast surgery setup. Positional and rotational electromagnetic tracking errors were then calculated using optical tracking as a ground truth. RESULTS: Our system is quick to set up and can be rapidly deployed. The process from calibration to visualization also only takes a few minutes. Field distortion was measured in the presence of various surgical equipment. Positional and rotational error in a clean field was approximately 0.90 mm and 0.31°. The presence of a surgical table, an electrosurgical cautery, and anesthesia machine increased the error by up to a few tenths of a millimeter and tenth of a degree. CONCLUSION: In a navigated breast surgery setup, measurement and visualization of tracking error defines a safe working area in the presence of surgical equipment. Our system is available as an extension for the open-source 3D Slicer platform.

  17. Control apparatus and method for efficiently heating a fuel processor in a fuel cell system

    DOEpatents

    Doan, Tien M.; Clingerman, Bruce J.

    2003-08-05

    A control apparatus and method for efficiently controlling the amount of heat generated by a fuel cell processor in a fuel cell system by determining a temperature error between actual and desired fuel processor temperatures. The temperature error is converted to a combustor fuel injector command signal or a heat dump valve position command signal depending upon the type of temperature error. Logic controls are responsive to the combustor fuel injector command signals and the heat dump valve position command signal to prevent the combustor fuel injector command signal from being generated if the heat dump valve is opened or, alternately, from preventing the heat dump valve position command signal from being generated if the combustor fuel injector is opened.

  18. Impact of Non-Gaussian Error Volumes on Conjunction Assessment Risk Analysis

    NASA Technical Reports Server (NTRS)

    Ghrist, Richard W.; Plakalovic, Dragan

    2012-01-01

    An understanding of how an initially Gaussian error volume becomes non-Gaussian over time is an important consideration for space-vehicle conjunction assessment. Traditional assumptions applied to the error volume artificially suppress the true non-Gaussian nature of the space-vehicle position uncertainties. For typical conjunction assessment objects, representation of the error volume by a state error covariance matrix in a Cartesian reference frame is a more significant limitation than is the assumption of linearized dynamics for propagating the error volume. In this study, the impact of each assumption is examined and isolated for each point in the volume. Limitations arising from representing the error volume in a Cartesian reference frame is corrected by employing a Monte Carlo approach to probability of collision (Pc), using equinoctial samples from the Cartesian position covariance at the time of closest approach (TCA) between the pair of space objects. A set of actual, higher risk (Pc >= 10 (exp -4)+) conjunction events in various low-Earth orbits using Monte Carlo methods are analyzed. The impact of non-Gaussian error volumes on Pc for these cases is minimal, even when the deviation from a Gaussian distribution is significant.

  19. Asynchronous RTK precise DGNSS positioning method for deriving a low-latency high-rate output

    NASA Astrophysics Data System (ADS)

    Liang, Zhang; Hanfeng, Lv; Dingjie, Wang; Yanqing, Hou; Jie, Wu

    2015-07-01

    Low-latency high-rate (1 Hz) precise real-time kinematic (RTK) can be applied in high-speed scenarios such as aircraft automatic landing, precise agriculture and intelligent vehicle. The classic synchronous RTK (SRTK) precise differential GNSS (DGNSS) positioning technology, however, is not able to obtain a low-latency high-rate output for the rover receiver because of long data link transmission time delays (DLTTD) from the reference receiver. To overcome the long DLTTD, this paper proposes an asynchronous real-time kinematic (ARTK) method using asynchronous observations from two receivers. The asynchronous observation model (AOM) is developed based on undifferenced carrier phase observation equations of the two receivers at different epochs with short baseline. The ephemeris error and atmosphere delay are the possible main error sources on positioning accuracy in this model, and they are analyzed theoretically. In a short DLTTD and during a period of quiet ionosphere activity, the main error sources decreasing positioning accuracy are satellite orbital errors: the "inverted ephemeris error" and the integration of satellite velocity error which increase linearly along with DLTTD. The cycle slip of asynchronous double-differencing carrier phase is detected by TurboEdit method and repaired by the additional ambiguity parameter method. The AOM can deal with synchronous observation model (SOM) and achieve precise positioning solution with synchronous observations as well, since the SOM is only a specific case of AOM. The proposed method not only can reduce the cost of data collection and transmission, but can also support the mobile phone network data link transfer mode for the data of the reference receiver. This method can avoid data synchronizing process besides ambiguity initialization step, which is very convenient for real-time navigation of vehicles. The static and kinematic experiment results show that this method achieves 20 Hz or even higher rate output in real time. The ARTK positioning accuracy is better and more robust than the combination of phase difference over time (PDOT) and SRTK method at a high rate. The ARTK positioning accuracy is equivalent to SRTK solution when the DLTTD is 0.5 s, and centimeter level accuracy can be achieved even when DLTTD is 15 s.

  20. VizieR Online Data Catalog: V and R CCD photometry of visual binaries (Abad+, 2004)

    NASA Astrophysics Data System (ADS)

    Abad, C.; Docobo, J. A.; Lanchares, V.; Lahulla, J. F.; Abelleira, P.; Blanco, J.; Alvarez, C.

    2003-11-01

    Table 1 gives relevant data for the visual binaries observed. Observations were carried out over a short period of time, therefore we assign the mean epoch (1998.58) for the totality of data. Data of individual stars are presented as average data with errors, by parameter, when various observations have been calculated, as well as the number of observations involved. Errors corresponding to astrometric relative positions between components are always present. For single observations, parameter fitting errors, specially for dx and dy parameters, have been calculated analysing the chi2 test around the minimum. Following the rules for error propagation, theta and rho errors can be estimated. Then, Table 1 shows single observation errors with an additional significant digit. When a star does not have known references, we include it in Table 2, where J2000 position and magnitudes are from the USNO-A2.0 catalogue (Monet et al., 1998, Cat. ). (2 data files).

  1. Long-term academic stress increases the late component of error processing: an ERP study.

    PubMed

    Wu, Jianhui; Yuan, Yiran; Duan, Hongxia; Qin, Shaozheng; Buchanan, Tony W; Zhang, Kan; Zhang, Liang

    2014-05-01

    Exposure to long-term stress has a variety of consequences on the brain and cognition. Few studies have examined the influence of long-term stress on event related potential (ERP) indices of error processing. The current study investigated how long-term academic stress modulates the error related negativity (Ne or ERN) and the error positivity (Pe) components of error processing. Forty-one male participants undergoing preparation for a major academic examination and 20 non-exam participants completed a Go-NoGo task while ERP measures were collected. The exam group reported higher perceived stress levels and showed increased Pe amplitude compared with the non-exam group. Participants' rating of the importance of the exam was positively associated with the amplitude of Pe, but these effects were not found for the Ne/ERN. These results suggest that long-term academic stress leads to greater motivational assessment of and higher emotional response to errors. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Poster - Thurs Eve-12: A needle-positioning robot co-registered with volumetric x-ray micro-computed tomography images for minimally-invasive small-animal interventions.

    PubMed

    Waspe, A C; Holdsworth, D W; Lacefield, J C; Fenster, A

    2008-07-01

    Preclinical research protocols often require the delivery of biological substances to specific targets in small animal disease models. To target biologically relevant locations in mice accurately, the needle positioning error needs to be < 200 μm. If targeting is inaccurate, experimental results can be inconclusive or misleading. We have developed a robotic manipulator that is capable of positioning a needle with a mean error < 100 μm. An apparatus and method were developed for integrating the needle-positioning robot with volumetric micro-computed tomography image guidance for interventions in small animals. Accurate image-to-robot registration is critical for integration as it enables targets identified in the image to be mapped to physical coordinates inside the animal. Registration is accomplished by injecting barium sulphate into needle tracks as the robot withdraws the needle from target points in a tissue-mimicking phantom. Registration accuracy is therefore affected by the positioning error of the robot and is assessed by measuring the point-to-line fiducial and target registration errors (FRE, TRE). Centroid points along cross-sectional slices of the track are determined using region growing segmentation followed by application of a center-of-mass algorithm. The centerline points are registered to needle trajectories in robot coordinates by applying an iterative closest point algorithm between points and lines. Implementing this procedure with four fiducial needle tracks produced a point-to-line FRE and TRE of 246 ± 58 μm and 194 ± 18 μm, respectively. The proposed registration technique produced a TRE < 200 μm, in the presence of robot positioning error, meeting design specification. © 2008 American Association of Physicists in Medicine.

  3. First clinical experience in carbon ion scanning beam therapy: retrospective analysis of patient positional accuracy.

    PubMed

    Mori, Shinichiro; Shibayama, Kouichi; Tanimoto, Katsuyuki; Kumagai, Motoki; Matsuzaki, Yuka; Furukawa, Takuji; Inaniwa, Taku; Shirai, Toshiyuki; Noda, Koji; Tsuji, Hiroshi; Kamada, Tadashi

    2012-09-01

    Our institute has constructed a new treatment facility for carbon ion scanning beam therapy. The first clinical trials were successfully completed at the end of November 2011. To evaluate patient setup accuracy, positional errors between the reference Computed Tomography (CT) scan and final patient setup images were calculated using 2D-3D registration software. Eleven patients with tumors of the head and neck, prostate and pelvis receiving carbon ion scanning beam treatment participated. The patient setup process takes orthogonal X-ray flat panel detector (FPD) images and the therapists adjust the patient table position in six degrees of freedom to register the reference position by manual or auto- (or both) registration functions. We calculated residual positional errors with the 2D-3D auto-registration function using the final patient setup orthogonal FPD images and treatment planning CT data. Residual error averaged over all patients in each fraction decreased from the initial to the last treatment fraction [1.09 mm/0.76° (averaged in the 1st and 2nd fractions) to 0.77 mm/0.61° (averaged in the 15th and 16th fractions)]. 2D-3D registration calculation time was 8.0 s on average throughout the treatment course. Residual errors in translation and rotation averaged over all patients as a function of date decreased with the passage of time (1.6 mm/1.2° in May 2011 to 0.4 mm/0.2° in December 2011). This retrospective residual positional error analysis shows that the accuracy of patient setup during the first clinical trials of carbon ion beam scanning therapy was good and improved with increasing therapist experience.

  4. Study on the influence of stochastic properties of correction terms on the reliability of instantaneous network RTK

    NASA Astrophysics Data System (ADS)

    Próchniewicz, Dominik

    2014-03-01

    The reliability of precision GNSS positioning primarily depends on correct carrier-phase ambiguity resolution. An optimal estimation and correct validation of ambiguities necessitates a proper definition of mathematical positioning model. Of particular importance in the model definition is the taking into account of the atmospheric errors (ionospheric and tropospheric refraction) as well as orbital errors. The use of the network of reference stations in kinematic positioning, known as Network-based Real-Time Kinematic (Network RTK) solution, facilitates the modeling of such errors and their incorporation, in the form of correction terms, into the functional description of positioning model. Lowered accuracy of corrections, especially during atmospheric disturbances, results in the occurrence of unaccounted biases, the so-called residual errors. The taking into account of such errors in Network RTK positioning model is possible by incorporating the accuracy characteristics of the correction terms into the stochastic model of observations. In this paper we investigate the impact of the expansion of the stochastic model to include correction term variances on the reliability of the model solution. In particular the results of instantaneous solution that only utilizes a single epoch of GPS observations, is analyzed. Such a solution mode due to the low number of degrees of freedom is very sensitive to an inappropriate mathematical model definition. Thus the high level of the solution reliability is very difficult to achieve. Numerical tests performed for a test network located in mountain area during ionospheric disturbances allows to verify the described method for the poor measurement conditions. The results of the ambiguity resolution as well as the rover positioning accuracy shows that the proposed method of stochastic modeling can increase the reliability of instantaneous Network RTK performance.

  5. "Fragment errors" in deep dysgraphia: further support for a lexical hypothesis.

    PubMed

    Bormann, Tobias; Wallesch, Claus-W; Blanken, Gerhard

    2008-07-01

    In addition to various lexical errors, the writing of patients with deep dysgraphia may include a large number of segmental spelling errors, which increase towards the end of the word. Frequently, these errors involve deletion of two or more letters resulting in so-called "fragment errors". Different positions have been brought forward regarding their origin, including rapid decay of activation in the graphemic buffer and an impairment of more central (i.e., lexical or semantic) processing. We present data from a patient (M.D.) with deep dysgraphia who showed an increase of segmental spelling errors towards the end of the word. Several tasks were carried out to explore M.D.'s underlying functional impairment. Errors affected word-final positions in tasks like backward spelling and fragment completion. In a delayed copying task, length of the delay had no influence. In addition, when asked to recall three serially presented letters, a task which had not been carried out before, M.D. exhibited a preference for the first and the third letter and poor performance for the second letter. M.D.'s performance on these tasks contradicts the rapid decay account and instead supports a lexical-semantic account of segmental errors in deep dysgraphia. In addition, the results fit well with an implemented computational model of deep dysgraphia and segmental spelling errors.

  6. Associations between food environment around schools and professionally measured weight status for middle and high school students.

    PubMed

    Tang, Xuyang; Ohri-Vachaspati, Punam; Abbott, Joshua K; Aggarwal, Rimjhim; Tulloch, David L; Lloyd, Kristen; Yedidia, Michael J

    2014-12-01

    Obesity rates among school-age children remain high. Access to energy-dense foods at home, in schools, in stores, and restaurants around homes and schools is of concern. Research on the relationship between food environment around schools and students' weight status is inconclusive. This study examines the association between weight status of middle and high school students and proximity to a comprehensive set of food outlets around schools. Deidentified nurse-measured heights and weights data were obtained for 12,954 middle and high school students attending 33 public schools in four low-income communities in New Jersey. Geocoded locations of supermarkets, convenience stores, small grocery stores, and limited-service restaurants were obtained from commercial sources. Random-effect regression models with robust standard errors were developed to adjust for unequal variances across schools and clustering of students within schools. Proximity to small grocery stores that offered some healthy options (e.g., five fruits, five vegetables, and low-fat/skim milk) and supermarkets was associated with healthier student weight status. Having a small grocery store within 0.25 mile of school and an additional such store within that radius was associated with a lower BMI z-score (p<0.05). An additional supermarket within 0.25 mile of schools was associated with a lower probability of being overweight/obese (p<0.05). Improving access to healthy food outlets, such as small stores, that offer healthy food options and supermarkets around middle and high schools is a potential strategy for improving weight outcomes among students.

  7. Identifying areas at risk of low birth weight using spatial epidemiology: A small area surveillance study.

    PubMed

    Insaf, Tabassum Z; Talbot, Thomas

    2016-07-01

    To assess the geographic distribution of Low Birth Weight (LBW) in New York State among singleton births using a spatial regression approach in order to identify priority areas for public health actions. LBW was defined as birth weight less than 2500g. Geocoded data from 562,586 birth certificates in New York State (years 2008-2012) were merged with 2010 census data at the tract level. To provide stable estimates and maintain confidentiality, data were aggregated to yield 1268 areas of analysis. LBW prevalence among singleton births was related with area-level behavioral, socioeconomic and demographic characteristics using a Poisson mixed effects spatial error regression model. Observed low birth weight showed statistically significant auto-correlation in our study area (Moran's I 0.16 p value 0.0005). After over-dispersion correction and accounting for fixed effects for selected social determinants, spatial autocorrelation was fully accounted for (Moran's I-0.007 p value 0.241). The proportion of LBW was higher in areas with larger Hispanic or Black populations and high smoking prevalence. Smoothed maps with predicted prevalence were developed to identify areas at high risk of LBW. Spatial patterns of residual variation were analyzed to identify unique risk factors. Neighborhood racial composition contributes to disparities in LBW prevalence beyond differences in behavioral and socioeconomic factors. Small-area analyses of LBW can identify areas for targeted interventions and display unique local patterns that should be accounted for in prevention strategies. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Neighborhood Disadvantage and Cumulative Biological Risk Among a Socioeconomically Diverse Sample of African American Adults: An Examination in the Jackson Heart Study.

    PubMed

    Barber, Sharrelle; Hickson, DeMarc A; Kawachi, Ichiro; Subramanian, S V; Earls, Felton

    2016-09-01

    Neighborhoods characterized by disadvantage influence multiple risk factors for chronic disease and are considered potential drivers of racial and ethnic health inequities in the USA. The objective of the present study was to examine the relationship between neighborhood disadvantage and cumulative biological risk (CBR) and the extent to which the association differs by individual income and education among a large, socioeconomically diverse sample of African American adults. Data from the baseline examination of the Jackson Heart Study (2000-2004) were used for the analyses. The sample consisted of African American adults ages 21-85 with complete, geocoded data on CBR biomarkers and behavioral covariates (n = 4410). Neighborhood disadvantage was measured using a composite score of socioeconomic indicators from the 2000 US Census. Eight biomarkers representing cardiovascular, metabolic, inflammatory, and neuroendocrine systems were used to create a CBR score. We fit two-level linear regression models with random intercepts and included cross-level interaction terms between neighborhood disadvantage and individual socioeconomic status (SES). Living in a disadvantaged neighborhood was associated with greater CBR after covariate adjustment (B = 0.18, standard error (SE) 0.07, p < 0.05). Interactions showed a weaker association for individuals with ≤high school education but were not statistically significant. Disadvantaged neighborhoods contribute to poor health among African American adults via cumulative biological risk. Policies directly addressing the socioeconomic conditions of these environments should be considered as viable options to reduce disease risk in this group and mitigate racial/ethnic health inequities.

  9. Associations between Food Environment around Schools and Professionally Measured Weight Status for Middle and High School Students

    PubMed Central

    Tang, Xuyang; Abbott, Joshua K.; Aggarwal, Rimjhim; Tulloch, David L.; Lloyd, Kristen; Yedidia, Michael J.

    2014-01-01

    Abstract Background: Obesity rates among school-age children remain high. Access to energy-dense foods at home, in schools, in stores, and restaurants around homes and schools is of concern. Research on the relationship between food environment around schools and students' weight status is inconclusive. This study examines the association between weight status of middle and high school students and proximity to a comprehensive set of food outlets around schools. Methods: Deidentified nurse-measured heights and weights data were obtained for 12,954 middle and high school students attending 33 public schools in four low-income communities in New Jersey. Geocoded locations of supermarkets, convenience stores, small grocery stores, and limited-service restaurants were obtained from commercial sources. Random-effect regression models with robust standard errors were developed to adjust for unequal variances across schools and clustering of students within schools. Results: Proximity to small grocery stores that offered some healthy options (e.g., five fruits, five vegetables, and low-fat/skim milk) and supermarkets was associated with healthier student weight status. Having a small grocery store within 0.25 mile of school and an additional such store within that radius was associated with a lower BMI z-score (p<0.05). An additional supermarket within 0.25 mile of schools was associated with a lower probability of being overweight/obese (p<0.05). Conclusions: Improving access to healthy food outlets, such as small stores, that offer healthy food options and supermarkets around middle and high schools is a potential strategy for improving weight outcomes among students. PMID:25343730

  10. Human leader and robot follower team: correcting leader's position from follower's heading

    NASA Astrophysics Data System (ADS)

    Borenstein, Johann; Thomas, David; Sights, Brandon; Ojeda, Lauro; Bankole, Peter; Fellars, Donald

    2010-04-01

    In multi-agent scenarios, there can be a disparity in the quality of position estimation amongst the various agents. Here, we consider the case of two agents - a leader and a follower - following the same path, in which the follower has a significantly better estimate of position and heading. This may be applicable to many situations, such as a robotic "mule" following a soldier. Another example is that of a convoy, in which only one vehicle (not necessarily the leading one) is instrumented with precision navigation instruments while all other vehicles use lower-precision instruments. We present an algorithm, called Follower-derived Heading Correction (FDHC), which substantially improves estimates of the leader's heading and, subsequently, position. Specifically, FHDC produces a very accurate estimate of heading errors caused by slow-changing errors (e.g., those caused by drift in gyros) of the leader's navigation system and corrects those errors.

  11. Error Estimation for the Linearized Auto-Localization Algorithm

    PubMed Central

    Guevara, Jorge; Jiménez, Antonio R.; Prieto, Jose Carlos; Seco, Fernando

    2012-01-01

    The Linearized Auto-Localization (LAL) algorithm estimates the position of beacon nodes in Local Positioning Systems (LPSs), using only the distance measurements to a mobile node whose position is also unknown. The LAL algorithm calculates the inter-beacon distances, used for the estimation of the beacons’ positions, from the linearized trilateration equations. In this paper we propose a method to estimate the propagation of the errors of the inter-beacon distances obtained with the LAL algorithm, based on a first order Taylor approximation of the equations. Since the method depends on such approximation, a confidence parameter τ is defined to measure the reliability of the estimated error. Field evaluations showed that by applying this information to an improved weighted-based auto-localization algorithm (WLAL), the standard deviation of the inter-beacon distances can be improved by more than 30% on average with respect to the original LAL method. PMID:22736965

  12. Modeling and simulation for fewer-axis grinding of complex surface

    NASA Astrophysics Data System (ADS)

    Li, Zhengjian; Peng, Xiaoqiang; Song, Ci

    2017-10-01

    As the basis of fewer-axis grinding of complex surface, the grinding mathematical model is of great importance. A mathematical model of the grinding wheel was established, and then coordinate and normal vector of the wheel profile could be calculated. Through normal vector matching at the cutter contact point and the coordinate system transformation, the grinding mathematical model was established to work out the coordinate of the cutter location point. Based on the model, interference analysis was simulated to find out the right position and posture of workpiece for grinding. Then positioning errors of the workpiece including the translation positioning error and the rotation positioning error were analyzed respectively, and the main locating datum was obtained. According to the analysis results, the grinding tool path was planned and generated to grind the complex surface, and good form accuracy was obtained. The grinding mathematical model is simple, feasible and can be widely applied.

  13. Inertial and time-of-arrival ranging sensor fusion.

    PubMed

    Vasilyev, Paul; Pearson, Sean; El-Gohary, Mahmoud; Aboy, Mateo; McNames, James

    2017-05-01

    Wearable devices with embedded kinematic sensors including triaxial accelerometers, gyroscopes, and magnetometers are becoming widely used in applications for tracking human movement in domains that include sports, motion gaming, medicine, and wellness. The kinematic sensors can be used to estimate orientation, but can only estimate changes in position over short periods of time. We developed a prototype sensor that includes ultra wideband ranging sensors and kinematic sensors to determine the feasibility of fusing the two sensor technologies to estimate both orientation and position. We used a state space model and applied the unscented Kalman filter to fuse the sensor information. Our results demonstrate that it is possible to estimate orientation and position with less error than is possible with either sensor technology alone. In our experiment we obtained a position root mean square error of 5.2cm and orientation error of 4.8° over a 15min recording. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Two-UAV Intersection Localization System Based on the Airborne Optoelectronic Platform

    PubMed Central

    Bai, Guanbing; Liu, Jinghong; Song, Yueming; Zuo, Yujia

    2017-01-01

    To address the limitation of the existing UAV (unmanned aerial vehicles) photoelectric localization method used for moving objects, this paper proposes an improved two-UAV intersection localization system based on airborne optoelectronic platforms by using the crossed-angle localization method of photoelectric theodolites for reference. This paper introduces the makeup and operating principle of intersection localization system, creates auxiliary coordinate systems, transforms the LOS (line of sight, from the UAV to the target) vectors into homogeneous coordinates, and establishes a two-UAV intersection localization model. In this paper, the influence of the positional relationship between UAVs and the target on localization accuracy has been studied in detail to obtain an ideal measuring position and the optimal localization position where the optimal intersection angle is 72.6318°. The result shows that, given the optimal position, the localization root mean square error (RMS) will be 25.0235 m when the target is 5 km away from UAV baselines. Finally, the influence of modified adaptive Kalman filtering on localization results is analyzed, and an appropriate filtering model is established to reduce the localization RMS error to 15.7983 m. Finally, An outfield experiment was carried out and obtained the optimal results: σB=1.63×10−4 (°), σL=1.35×10−4 (°), σH=15.8 (m), σsum=27.6 (m), where σB represents the longitude error, σL represents the latitude error, σH represents the altitude error, and σsum represents the error radius. PMID:28067814

  15. Two-UAV Intersection Localization System Based on the Airborne Optoelectronic Platform.

    PubMed

    Bai, Guanbing; Liu, Jinghong; Song, Yueming; Zuo, Yujia

    2017-01-06

    To address the limitation of the existing UAV (unmanned aerial vehicles) photoelectric localization method used for moving objects, this paper proposes an improved two-UAV intersection localization system based on airborne optoelectronic platforms by using the crossed-angle localization method of photoelectric theodolites for reference. This paper introduces the makeup and operating principle of intersection localization system, creates auxiliary coordinate systems, transforms the LOS (line of sight, from the UAV to the target) vectors into homogeneous coordinates, and establishes a two-UAV intersection localization model. In this paper, the influence of the positional relationship between UAVs and the target on localization accuracy has been studied in detail to obtain an ideal measuring position and the optimal localization position where the optimal intersection angle is 72.6318°. The result shows that, given the optimal position, the localization root mean square error (RMS) will be 25.0235 m when the target is 5 km away from UAV baselines. Finally, the influence of modified adaptive Kalman filtering on localization results is analyzed, and an appropriate filtering model is established to reduce the localization RMS error to 15.7983 m. Finally, An outfield experiment was carried out and obtained the optimal results: σ B = 1.63 × 10 - 4 ( ° ) , σ L = 1.35 × 10 - 4 ( ° ) , σ H = 15.8 ( m ) , σ s u m = 27.6 ( m ) , where σ B represents the longitude error, σ L represents the latitude error, σ H represents the altitude error, and σ s u m represents the error radius.

  16. Virtual occlusal definition for orthognathic surgery.

    PubMed

    Liu, X J; Li, Q Q; Zhang, Z; Li, T T; Xie, Z; Zhang, Y

    2016-03-01

    Computer-assisted surgical simulation is being used increasingly in orthognathic surgery. However, occlusal definition is still undertaken using model surgery with subsequent digitization via surface scanning or cone beam computed tomography. A software tool has been developed and a workflow set up in order to achieve a virtual occlusal definition. The results of a validation study carried out on 60 models of normal occlusion are presented. Inter- and intra-user correlation tests were used to investigate the reproducibility of the manual setting point procedure. The errors between the virtually set positions (test) and the digitized manually set positions (gold standard) were compared. The consistency in virtual set positions performed by three individual users was investigated by one way analysis of variance test. Inter- and intra-observer correlation coefficients for manual setting points were all greater than 0.95. Overall, the median error between the test and the gold standard positions was 1.06mm. Errors did not differ among teeth (F=0.371, P>0.05). The errors were not significantly different from 1mm (P>0.05). There were no significant differences in the errors made by the three independent users (P>0.05). In conclusion, this workflow for virtual occlusal definition was found to be reliable and accurate. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Reaching nearby sources: comparison between real and virtual sound and visual targets

    PubMed Central

    Parseihian, Gaëtan; Jouffrais, Christophe; Katz, Brian F. G.

    2014-01-01

    Sound localization studies over the past century have predominantly been concerned with directional accuracy for far-field sources. Few studies have examined the condition of near-field sources and distance perception. The current study concerns localization and pointing accuracy by examining source positions in the peripersonal space, specifically those associated with a typical tabletop surface. Accuracy is studied with respect to the reporting hand (dominant or secondary) for auditory sources. Results show no effect on the reporting hand with azimuthal errors increasing equally for the most extreme source positions. Distance errors show a consistent compression toward the center of the reporting area. A second evaluation is carried out comparing auditory and visual stimuli to examine any bias in reporting protocol or biomechanical difficulties. No common bias error was observed between auditory and visual stimuli indicating that reporting errors were not due to biomechanical limitations in the pointing task. A final evaluation compares real auditory sources and anechoic condition virtual sources created using binaural rendering. Results showed increased azimuthal errors, with virtual source positions being consistently overestimated to more lateral positions, while no significant distance perception was observed, indicating a deficiency in the binaural rendering condition relative to the real stimuli situation. Various potential reasons for this discrepancy are discussed with several proposals for improving distance perception in peripersonal virtual environments. PMID:25228855

  18. Characteristics of the BDS Carrier Phase Multipath and Its Mitigation Methods in Relative Positioning

    PubMed Central

    Dai, Wujiao; Shi, Qiang; Cai, Changsheng

    2017-01-01

    The carrier phase multipath effect is one of the most significant error sources in the precise positioning of BeiDou Navigation Satellite System (BDS). We analyzed the characteristics of BDS multipath, and found the multipath errors of geostationary earth orbit (GEO) satellite signals are systematic, whereas those of inclined geosynchronous orbit (IGSO) or medium earth orbit (MEO) satellites are both systematic and random. The modified multipath mitigation methods, including sidereal filtering algorithm and multipath hemispherical map (MHM) model, were used to improve BDS dynamic deformation monitoring. The results indicate that the sidereal filtering methods can reduce the root mean square (RMS) of positioning errors in the east, north and vertical coordinate directions by 15%, 37%, 25% and 18%, 51%, 27% in the coordinate and observation domains, respectively. By contrast, the MHM method can reduce the RMS by 22%, 52% and 27% on average. In addition, the BDS multipath errors in static baseline solutions are a few centimeters in multipath-rich environments, which is different from that of Global Positioning System (GPS) multipath. Therefore, we add a parameter representing the GEO multipath error in observation equation to the adjustment model to improve the precision of BDS static baseline solutions. And the results show that the modified model can achieve an average precision improvement of 82%, 54% and 68% in the east, north and up coordinate directions, respectively. PMID:28387744

  19. Characteristics of the BDS Carrier Phase Multipath and Its Mitigation Methods in Relative Positioning.

    PubMed

    Dai, Wujiao; Shi, Qiang; Cai, Changsheng

    2017-04-07

    The carrier phase multipath effect is one of the most significant error sources in the precise positioning of BeiDou Navigation Satellite System (BDS). We analyzed the characteristics of BDS multipath, and found the multipath errors of geostationary earth orbit (GEO) satellite signals are systematic, whereas those of inclined geosynchronous orbit (IGSO) or medium earth orbit (MEO) satellites are both systematic and random. The modified multipath mitigation methods, including sidereal filtering algorithm and multipath hemispherical map (MHM) model, were used to improve BDS dynamic deformation monitoring. The results indicate that the sidereal filtering methods can reduce the root mean square (RMS) of positioning errors in the east, north and vertical coordinate directions by 15%, 37%, 25% and 18%, 51%, 27% in the coordinate and observation domains, respectively. By contrast, the MHM method can reduce the RMS by 22%, 52% and 27% on average. In addition, the BDS multipath errors in static baseline solutions are a few centimeters in multipath-rich environments, which is different from that of Global Positioning System (GPS) multipath. Therefore, we add a parameter representing the GEO multipath error in observation equation to the adjustment model to improve the precision of BDS static baseline solutions. And the results show that the modified model can achieve an average precision improvement of 82%, 54% and 68% in the east, north and up coordinate directions, respectively.

  20. Requirements for Coregistration Accuracy in On-Scalp MEG.

    PubMed

    Zetter, Rasmus; Iivanainen, Joonas; Stenroos, Matti; Parkkonen, Lauri

    2018-06-22

    Recent advances in magnetic sensing has made on-scalp magnetoencephalography (MEG) possible. In particular, optically-pumped magnetometers (OPMs) have reached sensitivity levels that enable their use in MEG. In contrast to the SQUID sensors used in current MEG systems, OPMs do not require cryogenic cooling and can thus be placed within millimetres from the head, enabling the construction of sensor arrays that conform to the shape of an individual's head. To properly estimate the location of neural sources within the brain, one must accurately know the position and orientation of sensors in relation to the head. With the adaptable on-scalp MEG sensor arrays, this coregistration becomes more challenging than in current SQUID-based MEG systems that use rigid sensor arrays. Here, we used simulations to quantify how accurately one needs to know the position and orientation of sensors in an on-scalp MEG system. The effects that different types of localisation errors have on forward modelling and source estimates obtained by minimum-norm estimation, dipole fitting, and beamforming are detailed. We found that sensor position errors generally have a larger effect than orientation errors and that these errors affect the localisation accuracy of superficial sources the most. To obtain similar or higher accuracy than with current SQUID-based MEG systems, RMS sensor position and orientation errors should be [Formula: see text] and [Formula: see text], respectively.

  1. Three-dimensional high-precision indoor positioning strategy using Tabu search based on visible light communication

    NASA Astrophysics Data System (ADS)

    Peng, Qi; Guan, Weipeng; Wu, Yuxiang; Cai, Ye; Xie, Canyu; Wang, Pengfei

    2018-01-01

    This paper proposes a three-dimensional (3-D) high-precision indoor positioning strategy using Tabu search based on visible light communication. Tabu search is a powerful global optimization algorithm, and the 3-D indoor positioning can be transformed into an optimal solution problem. Therefore, in the 3-D indoor positioning, the optimal receiver coordinate can be obtained by the Tabu search algorithm. For all we know, this is the first time the Tabu search algorithm is applied to visible light positioning. Each light-emitting diode (LED) in the system broadcasts a unique identity (ID) and transmits the ID information. When the receiver detects optical signals with ID information from different LEDs, using the global optimization of the Tabu search algorithm, the 3-D high-precision indoor positioning can be realized when the fitness value meets certain conditions. Simulation results show that the average positioning error is 0.79 cm, and the maximum error is 5.88 cm. The extended experiment of trajectory tracking also shows that 95.05% positioning errors are below 1.428 cm. It can be concluded from the data that the 3-D indoor positioning based on the Tabu search algorithm achieves the requirements of centimeter level indoor positioning. The algorithm used in indoor positioning is very effective and practical and is superior to other existing methods for visible light indoor positioning.

  2. Method for the fabrication error calibration of the CGH used in the cylindrical interferometry system

    NASA Astrophysics Data System (ADS)

    Wang, Qingquan; Yu, Yingjie; Mou, Kebing

    2016-10-01

    This paper presents a method of absolutely calibrating the fabrication error of the CGH in the cylindrical interferometry system for the measurement of cylindricity error. First, a simulated experimental system is set up in ZEMAX. On one hand, the simulated experimental system has demonstrated the feasibility of the method we proposed. On the other hand, by changing the different positions of the mirror in the simulated experimental system, a misalignment aberration map, consisting of the different interferograms in different positions, is acquired. And it can be acted as a reference for the experimental adjustment in real system. Second, the mathematical polynomial, which describes the relationship between the misalignment aberrations and the possible misalignment errors, is discussed.

  3. Wisdom in Medicine: What Helps Physicians After a Medical Error?

    PubMed

    Plews-Ogan, Margaret; May, Natalie; Owens, Justine; Ardelt, Monika; Shapiro, Jo; Bell, Sigall K

    2016-02-01

    Confronting medical error openly is critical to organizational learning, but less is known about what helps individual clinicians learn and adapt positively after making a harmful mistake. Understanding what factors help doctors gain wisdom can inform educational and peer support programs, and may facilitate the development of specific tools to assist doctors after harmful errors occur. Using "posttraumatic growth" as a model, the authors conducted semistructured interviews (2009-2011) with 61 physicians who had made a serious medical error. Interviews were recorded, professionally transcribed, and coded by two study team members (kappa 0.8) using principles of grounded theory and NVivo software. Coders also scored interviewees as wisdom exemplars or nonexemplars based on Ardelt's three-dimensional wisdom model. Of the 61 physicians interviewed, 33 (54%) were male, and on average, eight years had elapsed since the error. Wisdom exemplars were more likely to report disclosing the error to the patient/family (69%) than nonexemplars (38%); P < .03. Fewer than 10% of all participants reported receiving disclosure training. Investigators identified eight themes reflecting what helped physician wisdom exemplars cope positively: talking about it, disclosure and apology, forgiveness, a moral context, dealing with imperfection, learning/becoming an expert, preventing recurrences/improving teamwork, and helping others/teaching. The path forged by doctors who coped well with medical error highlights specific ways to help clinicians move through this difficult experience so that they avoid devastating professional outcomes and have the best chance of not just recovery but positive growth.

  4. A verification and errors analysis of the model for object positioning based on binocular stereo vision for airport surface surveillance

    NASA Astrophysics Data System (ADS)

    Wang, Huan-huan; Wang, Jian; Liu, Feng; Cao, Hai-juan; Wang, Xiang-jun

    2014-12-01

    A test environment is established to obtain experimental data for verifying the positioning model which was derived previously based on the pinhole imaging model and the theory of binocular stereo vision measurement. The model requires that the optical axes of the two cameras meet at one point which is defined as the origin of the world coordinate system, thus simplifying and optimizing the positioning model. The experimental data are processed and tables and charts are given for comparing the positions of objects measured with DGPS with a measurement accuracy of 10 centimeters as the reference and those measured with the positioning model. Sources of visual measurement model are analyzed, and the effects of the errors of camera and system parameters on the accuracy of positioning model were probed, based on the error transfer and synthesis rules. A conclusion is made that measurement accuracy of surface surveillances based on binocular stereo vision measurement is better than surface movement radars, ADS-B (Automatic Dependent Surveillance-Broadcast) and MLAT (Multilateration).

  5. A Simple Method to Improve Autonomous GPS Positioning for Tractors

    PubMed Central

    Gomez-Gil, Jaime; Alonso-Garcia, Sergio; Gómez-Gil, Francisco Javier; Stombaugh, Tim

    2011-01-01

    Error is always present in the GPS guidance of a tractor along a desired trajectory. One way to reduce GPS guidance error is by improving the tractor positioning. The most commonly used ways to do this are either by employing more precise GPS receivers and differential corrections or by employing GPS together with some other local positioning systems such as electronic compasses or Inertial Navigation Systems (INS). However, both are complex and expensive solutions. In contrast, this article presents a simple and low cost method to improve tractor positioning when only a GPS receiver is used as the positioning sensor. The method is based on placing the GPS receiver ahead of the tractor, and on applying kinematic laws of tractor movement, or a geometric approximation, to obtain the midpoint position and orientation of the tractor rear axle more precisely. This precision improvement is produced by the fusion of the GPS data with tractor kinematic control laws. Our results reveal that the proposed method effectively reduces the guidance GPS error along a straight trajectory. PMID:22163917

  6. New decoding methods of interleaved burst error-correcting codes

    NASA Astrophysics Data System (ADS)

    Nakano, Y.; Kasahara, M.; Namekawa, T.

    1983-04-01

    A probabilistic method of single burst error correction, using the syndrome correlation of subcodes which constitute the interleaved code, is presented. This method makes it possible to realize a high capability of burst error correction with less decoding delay. By generalizing this method it is possible to obtain probabilistic method of multiple (m-fold) burst error correction. After estimating the burst error positions using syndrome correlation of subcodes which are interleaved m-fold burst error detecting codes, this second method corrects erasure errors in each subcode and m-fold burst errors. The performance of these two methods is analyzed via computer simulation, and their effectiveness is demonstrated.

  7. Space-Borne Laser Altimeter Geolocation Error Analysis

    NASA Astrophysics Data System (ADS)

    Wang, Y.; Fang, J.; Ai, Y.

    2018-05-01

    This paper reviews the development of space-borne laser altimetry technology over the past 40 years. Taking the ICESAT satellite as an example, a rigorous space-borne laser altimeter geolocation model is studied, and an error propagation equation is derived. The influence of the main error sources, such as the platform positioning error, attitude measurement error, pointing angle measurement error and range measurement error, on the geolocation accuracy of the laser spot are analysed by simulated experiments. The reasons for the different influences on geolocation accuracy in different directions are discussed, and to satisfy the accuracy of the laser control point, a design index for each error source is put forward.

  8. [New possibilities screening of refractive errors among children].

    PubMed

    Ondrejková, M; Kyselová, P

    2013-06-01

    To establish early detection of refractive errors among children in Slovakia. Different screening methods have been evaluated and compared in this work. we have been working on a prospective study. Pre-school children in kindergardens in Central Slovakia were checked up between years 2009-2011. Effectiveness of various screening methods was compared within 2 groups, using test-type and Plusoptix Vision Screener. Parentęs of children positive to refractive errors were recommended to consult a paediatrician ophthalmologist. 3982 children were examined. As a result, 13-14.1% of children who have not been examinated by the specialist, were positive. 53.3% of them went to see the doctor afterwards. establishment of early refractive errors screening is an important method how to prevent strabismus and amblyopia. It is very important to improve parentęs knowledge about the risk of refractive errors and also to improve screening methods with collaboration with kindergarten teachers.

  9. Monetary Incentives in Speeded Perceptual Decision: Effects of Penalizing Errors Versus Slow Responses

    PubMed Central

    Dambacher, Michael; Hübner, Ronald; Schlösser, Jan

    2011-01-01

    The influence of monetary incentives on performance has been widely investigated among various disciplines. While the results reveal positive incentive effects only under specific conditions, the exact nature, and the contribution of mediating factors are largely unexplored. The present study examined influences of payoff schemes as one of these factors. In particular, we manipulated penalties for errors and slow responses in a speeded categorization task. The data show improved performance for monetary over symbolic incentives when (a) penalties are higher for slow responses than for errors, and (b) neither slow responses nor errors are punished. Conversely, payoff schemes with stronger punishment for errors than for slow responses resulted in worse performance under monetary incentives. The findings suggest that an emphasis of speed is favorable for positive influences of monetary incentives, whereas an emphasis of accuracy under time pressure has the opposite effect. PMID:21980316

  10. Reduction in specimen labeling errors after implementation of a positive patient identification system in phlebotomy.

    PubMed

    Morrison, Aileen P; Tanasijevic, Milenko J; Goonan, Ellen M; Lobo, Margaret M; Bates, Michael M; Lipsitz, Stuart R; Bates, David W; Melanson, Stacy E F

    2010-06-01

    Ensuring accurate patient identification is central to preventing medical errors, but it can be challenging. We implemented a bar code-based positive patient identification system for use in inpatient phlebotomy. A before-after design was used to evaluate the impact of the identification system on the frequency of mislabeled and unlabeled samples reported in our laboratory. Labeling errors fell from 5.45 in 10,000 before implementation to 3.2 in 10,000 afterward (P = .0013). An estimated 108 mislabeling events were prevented by the identification system in 1 year. Furthermore, a workflow step requiring manual preprinting of labels, which was accompanied by potential labeling errors in about one quarter of blood "draws," was removed as a result of the new system. After implementation, a higher percentage of patients reported having their wristband checked before phlebotomy. Bar code technology significantly reduced the rate of specimen identification errors.

  11. Patient motion tracking in the presence of measurement errors.

    PubMed

    Haidegger, Tamás; Benyó, Zoltán; Kazanzides, Peter

    2009-01-01

    The primary aim of computer-integrated surgical systems is to provide physicians with superior surgical tools for better patient outcome. Robotic technology is capable of both minimally invasive surgery and microsurgery, offering remarkable advantages for the surgeon and the patient. Current systems allow for sub-millimeter intraoperative spatial positioning, however certain limitations still remain. Measurement noise and unintended changes in the operating room environment can result in major errors. Positioning errors are a significant danger to patients in procedures involving robots and other automated devices. We have developed a new robotic system at the Johns Hopkins University to support cranial drilling in neurosurgery procedures. The robot provides advanced visualization and safety features. The generic algorithm described in this paper allows for automated compensation of patient motion through optical tracking and Kalman filtering. When applied to the neurosurgery setup, preliminary results show that it is possible to identify patient motion within 700 ms, and apply the appropriate compensation with an average of 1.24 mm positioning error after 2 s of setup time.

  12. Clinical measuring system for the form and position errors of circular workpieces using optical fiber sensors

    NASA Astrophysics Data System (ADS)

    Tan, Jiubin; Qiang, Xifu; Ding, Xuemei

    1991-08-01

    Optical sensors have two notable advantages in modern precision measurement. One is that they can be used in nondestructive measurement because the sensors need not touch the surfaces of workpieces in measuring. The other one is that they can strongly resist electromagnetic interferences, vibrations, and noises, so they are suitable to be used in machining sites. But the drift of light intensity and the changing of the reflection coefficient at different measuring positions of a workpiece may have great influence on measured results. To solve the problem, a spectroscopic differential characteristic compensating method is put forward. The method can be used effectively not only in compensating the measuring errors resulted from the drift of light intensity but also in eliminating the influence to measured results caused by the changing of the reflection coefficient. Also, the article analyzes the possibility of and the means of separating data errors of a clinical measuring system for form and position errors of circular workpieces.

  13. Poster - 49: Assessment of Synchrony respiratory compensation error for CyberKnife liver treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ming; Cygler,

    The goal of this work is to quantify respiratory motion compensation errors for liver tumor patients treated by the CyberKnife system with Synchrony tracking, to identify patients with the smallest tracking errors and to eventually help coach patient’s breathing patterns to minimize dose delivery errors. The accuracy of CyberKnife Synchrony respiratory motion compensation was assessed for 37 patients treated for liver lesions by analyzing data from system logfiles. A predictive model is used to modulate the direction of individual beams during dose delivery based on the positions of internally implanted fiducials determined using an orthogonal x-ray imaging system and themore » current location of LED external markers. For each x-ray pair acquired, system logfiles report the prediction error, the difference between the measured and predicted fiducial positions, and the delivery error, which is an estimate of the statistical error in the model overcoming the latency between x-ray acquisition and robotic repositioning. The total error was calculated at the time of each x-ray pair, for the number of treatment fractions and the number of patients, giving the average respiratory motion compensation error in three dimensions. The 99{sup th} percentile for the total radial error is 3.85 mm, with the highest contribution of 2.79 mm in superior/inferior (S/I) direction. The absolute mean compensation error is 1.78 mm radially with a 1.27 mm contribution in the S/I direction. Regions of high total error may provide insight into features predicting groups of patients with larger or smaller total errors.« less

  14. A simulation study to quantify the impacts of exposure ...

    EPA Pesticide Factsheets

    BackgroundExposure measurement error in copollutant epidemiologic models has the potential to introduce bias in relative risk (RR) estimates. A simulation study was conducted using empirical data to quantify the impact of correlated measurement errors in time-series analyses of air pollution and health.MethodsZIP-code level estimates of exposure for six pollutants (CO, NOx, EC, PM2.5, SO4, O3) from 1999 to 2002 in the Atlanta metropolitan area were used to calculate spatial, population (i.e. ambient versus personal), and total exposure measurement error.Empirically determined covariance of pollutant concentration pairs and the associated measurement errors were used to simulate true exposure (exposure without error) from observed exposure. Daily emergency department visits for respiratory diseases were simulated using a Poisson time-series model with a main pollutant RR = 1.05 per interquartile range, and a null association for the copollutant (RR = 1). Monte Carlo experiments were used to evaluate the impacts of correlated exposure errors of different copollutant pairs.ResultsSubstantial attenuation of RRs due to exposure error was evident in nearly all copollutant pairs studied, ranging from 10 to 40% attenuation for spatial error, 3–85% for population error, and 31–85% for total error. When CO, NOx or EC is the main pollutant, we demonstrated the possibility of false positives, specifically identifying significant, positive associations for copoll

  15. Influence of Pedometer Position on Pedometer Accuracy at Various Walking Speeds: A Comparative Study

    PubMed Central

    Lovis, Christian

    2016-01-01

    Background Demographic growth in conjunction with the rise of chronic diseases is increasing the pressure on health care systems in most OECD countries. Physical activity is known to be an essential factor in improving or maintaining good health. Walking is especially recommended, as it is an activity that can easily be performed by most people without constraints. Pedometers have been extensively used as an incentive to motivate people to become more active. However, a recognized problem with these devices is their diminishing accuracy associated with decreased walking speed. The arrival on the consumer market of new devices, worn indifferently either at the waist, wrist, or as a necklace, gives rise to new questions regarding their accuracy at these different positions. Objective Our objective was to assess the performance of 4 pedometers (iHealth activity monitor, Withings Pulse O2, Misfit Shine, and Garmin vívofit) and compare their accuracy according to their position worn, and at various walking speeds. Methods We conducted this study in a controlled environment with 21 healthy adults required to walk 100 m at 3 different paces (0.4 m/s, 0.6 m/s, and 0.8 m/s) regulated by means of a string attached between their legs at the level of their ankles and a metronome ticking the cadence. To obtain baseline values, we asked the participants to walk 200 m at their own pace. Results A decrease of accuracy was positively correlated with reduced speed for all pedometers (12% mean error at self-selected pace, 27% mean error at 0.8 m/s, 52% mean error at 0.6 m/s, and 76% mean error at 0.4 m/s). Although the position of the pedometer on the person did not significantly influence its accuracy, some interesting tendencies can be highlighted in 2 settings: (1) positioning the pedometer at the waist at a speed greater than 0.8 m/s or as a necklace at preferred speed tended to produce lower mean errors than at the wrist position; and (2) at a slow speed (0.4 m/s), pedometers worn at the wrist tended to produce a lower mean error than in the other positions. Conclusions At all positions, all tested pedometers generated significant errors at slow speeds and therefore cannot be used reliably to evaluate the amount of physical activity for people walking slower than 0.6 m/s (2.16 km/h, or 1.24 mph). At slow speeds, the better accuracy observed with pedometers worn at the wrist could constitute a valuable line of inquiry for the future development of devices adapted to elderly people. PMID:27713114

  16. New hybrid reverse differential pulse position width modulation scheme for wireless optical communication

    NASA Astrophysics Data System (ADS)

    Liao, Renbo; Liu, Hongzhan; Qiao, Yaojun

    2014-05-01

    In order to improve the power efficiency and reduce the packet error rate of reverse differential pulse position modulation (RDPPM) for wireless optical communication (WOC), a hybrid reverse differential pulse position width modulation (RDPPWM) scheme is proposed, based on RDPPM and reverse pulse width modulation. Subsequently, the symbol structure of RDPPWM is briefly analyzed, and its performance is compared with that of other modulation schemes in terms of average transmitted power, bandwidth requirement, and packet error rate over ideal additive white Gaussian noise (AWGN) channels. Based on the given model, the simulation results show that the proposed modulation scheme has the advantages of improving the power efficiency and reducing the bandwidth requirement. Moreover, in terms of error probability performance, RDPPWM can achieve a much lower packet error rate than that of RDPPM. For example, at the same received signal power of -28 dBm, the packet error rate of RDPPWM can decrease to 2.6×10-12, while that of RDPPM is 2.2×10. Furthermore, RDPPWM does not need symbol synchronization at the receiving end. These considerations make RDPPWM a favorable candidate to select as the modulation scheme in the WOC systems.

  17. Assessing Working Memory in Mild Cognitive Impairment with Serial Order Recall.

    PubMed

    Emrani, Sheina; Libon, David J; Lamar, Melissa; Price, Catherine C; Jefferson, Angela L; Gifford, Katherine A; Hohman, Timothy J; Nation, Daniel A; Delano-Wood, Lisa; Jak, Amy; Bangen, Katherine J; Bondi, Mark W; Brickman, Adam M; Manly, Jennifer; Swenson, Rodney; Au, Rhoda

    2018-01-01

    Working memory (WM) is often assessed with serial order tests such as repeating digits backward. In prior dementia research using the Backward Digit Span Test (BDT), only aggregate test performance was examined. The current research tallied primacy/recency effects, out-of-sequence transposition errors, perseverations, and omissions to assess WM deficits in patients with mild cognitive impairment (MCI). Memory clinic patients (n = 66) were classified into three groups: single domain amnestic MCI (aMCI), combined mixed domain/dysexecutive MCI (mixed/dys MCI), and non-MCI where patients did not meet criteria for MCI. Serial order/WM ability was assessed by asking participants to repeat 7 trials of five digits backwards. Serial order position accuracy, transposition errors, perseverations, and omission errors were tallied. A 3 (group)×5 (serial position) repeated measures ANOVA yielded a significant group×trial interaction. Follow-up analyses found attenuation of the recency effect for mixed/dys MCI patients. Mixed/dys MCI patients scored lower than non-MCI patients for serial position 3 (p < 0.003) serial position 4 (p < 0.002); and lower than both group for serial position 5 (recency; p < 0.002). Mixed/dys MCI patients also produced more transposition errors than both groups (p < 0.010); and more omissions (p < 0.020), and perseverations errors (p < 0.018) than non-MCI patients. The attenuation of a recency effect using serial order parameters obtained from the BDT may provide a useful operational definition as well as additional diagnostic information regarding working memory deficits in MCI.

  18. Long-Term Predictive and Feedback Encoding of Motor Signals in the Simple Spike Discharge of Purkinje Cells

    PubMed Central

    Popa, Laurentiu S.; Streng, Martha L.

    2017-01-01

    Abstract Most hypotheses of cerebellar function emphasize a role in real-time control of movements. However, the cerebellum’s use of current information to adjust future movements and its involvement in sequencing, working memory, and attention argues for predicting and maintaining information over extended time windows. The present study examines the time course of Purkinje cell discharge modulation in the monkey (Macaca mulatta) during manual, pseudo-random tracking. Analysis of the simple spike firing from 183 Purkinje cells during tracking reveals modulation up to 2 s before and after kinematics and position error. Modulation significance was assessed against trial shuffled firing, which decoupled simple spike activity from behavior and abolished long-range encoding while preserving data statistics. Position, velocity, and position errors have the most frequent and strongest long-range feedforward and feedback modulations, with less common, weaker long-term correlations for speed and radial error. Position, velocity, and position errors can be decoded from the population simple spike firing with considerable accuracy for even the longest predictive (-2000 to -1500 ms) and feedback (1500 to 2000 ms) epochs. Separate analysis of the simple spike firing in the initial hold period preceding tracking shows similar long-range feedforward encoding of the upcoming movement and in the final hold period feedback encoding of the just completed movement, respectively. Complex spike analysis reveals little long-term modulation with behavior. We conclude that Purkinje cell simple spike discharge includes short- and long-range representations of both upcoming and preceding behavior that could underlie cerebellar involvement in error correction, working memory, and sequencing. PMID:28413823

  19. Unavoidable Errors: A Spatio-Temporal Analysis of Time-Course and Neural Sources of Evoked Potentials Associated with Error Processing in a Speeded Task

    ERIC Educational Resources Information Center

    Vocat, Roland; Pourtois, Gilles; Vuilleumier, Patrik

    2008-01-01

    The detection of errors is known to be associated with two successive neurophysiological components in EEG, with an early time-course following motor execution: the error-related negativity (ERN/Ne) and late positivity (Pe). The exact cognitive and physiological processes contributing to these two EEG components, as well as their functional…

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fuangrod, T; Simpson, J; Greer, P

    Purpose: A real-time patient treatment delivery verification system using EPID (Watchdog) has been developed as an advanced patient safety tool. In a pilot study data was acquired for 119 prostate and head and neck (HN) IMRT patient deliveries to generate body-site specific action limits using statistical process control. The purpose of this study is to determine the sensitivity of Watchdog to detect clinically significant errors during treatment delivery. Methods: Watchdog utilizes a physics-based model to generate a series of predicted transit cine EPID images as a reference data set, and compares these in real-time to measured transit cine-EPID images acquiredmore » during treatment using chi comparison (4%, 4mm criteria) after the initial 2s of treatment to allow for dose ramp-up. Four study cases were used; dosimetric (monitor unit) errors in prostate (7 fields) and HN (9 fields) IMRT treatments of (5%, 7%, 10%) and positioning (systematic displacement) errors in the same treatments of (5mm, 7mm, 10mm). These errors were introduced by modifying the patient CT scan and re-calculating the predicted EPID data set. The error embedded predicted EPID data sets were compared to the measured EPID data acquired during patient treatment. The treatment delivery percentage (measured from 2s) where Watchdog detected the error was determined. Results: Watchdog detected all simulated errors for all fields during delivery. The dosimetric errors were detected at average treatment delivery percentage of (4%, 0%, 0%) and (7%, 0%, 0%) for prostate and HN respectively. For patient positional errors, the average treatment delivery percentage was (52%, 43%, 25%) and (39%, 16%, 6%). Conclusion: These results suggest that Watchdog can detect significant dosimetric and positioning errors in prostate and HN IMRT treatments in real-time allowing for treatment interruption. Displacements of the patient require longer to detect however incorrect body site or very large geographic misses will be detected rapidly.« less

  1. A statistical study of radio-source structure effects on astrometric very long baseline interferometry observations

    NASA Technical Reports Server (NTRS)

    Ulvestad, J. S.

    1989-01-01

    Errors from a number of sources in astrometric very long baseline interferometry (VLBI) have been reduced in recent years through a variety of methods of calibration and modeling. Such reductions have led to a situation in which the extended structure of the natural radio sources used in VLBI is a significant error source in the effort to improve the accuracy of the radio reference frame. In the past, work has been done on individual radio sources to establish the magnitude of the errors caused by their particular structures. The results of calculations on 26 radio sources are reported in which an effort is made to determine the typical delay and delay-rate errors for a number of sources having different types of structure. It is found that for single observations of the types of radio sources present in astrometric catalogs, group-delay and phase-delay scatter in the 50 to 100 psec range due to source structure can be expected at 8.4 GHz on the intercontinental baselines available in the Deep Space Network (DSN). Delay-rate scatter of approx. 5 x 10(exp -15) sec sec(exp -1) (or approx. 0.002 mm sec (exp -1) is also expected. If such errors mapped directly into source position errors, they would correspond to position uncertainties of approx. 2 to 5 nrad, similar to the best position determinations in the current JPL VLBI catalog. With the advent of wider bandwidth VLBI systems on the large DSN antennas, the system noise will be low enough so that the structure-induced errors will be a significant part of the error budget. Several possibilities for reducing the structure errors are discussed briefly, although it is likely that considerable effort will have to be devoted to the structure problem in order to reduce the typical error by a factor of two or more.

  2. Influence of chronic neck pain on cervical joint position error (JPE): Comparison between young and elderly subjects.

    PubMed

    Alahmari, Khalid A; Reddy, Ravi Shankar; Silvian, Paul; Ahmad, Irshad; Nagaraj, Venkat; Mahtab, Mohammad

    2017-11-06

    Evaluation of cervical joint position sense in subjects with chronic neck pain has gained importance in recent times. Different authors have established increased joint position error (JPE) in subjects with acute neck pain. However, there is a paucity of studies to establish the influence of chronic neck pain on cervical JPE. The objective of the study was to understand the influence of chronic neck pain on cervical JPE, and to examine the differences in cervical JPE between young and elderly subjects with chronic neck pain. Forty-two chronic neck pain patients (mean age 47.4) were compared for cervical JPE with 42 age-matched healthy subjects (mean age 47.8), using a digital inclinometer. The cervical JPE were measured in flexion, extension, and rotation in right and left movement directions. The comparison of JPE showed significantly larger errors in subjects with chronic neck pain when compared to healthy subjects (p< 0.001). The errors were larger in all of the movement directions tested. Comparison between young and older subjects with chronic neck pain revealed no significant differences (P> 0.05) in cervical JPE. Cervical joint position sense is impaired in subjects with chronic neck pain.

  3. Application of the phase shifting diffraction interferometer for measuring convex mirrors and negative lenses

    DOEpatents

    Sommargren, Gary E.; Campbell, Eugene W.

    2004-03-09

    To measure a convex mirror, a reference beam and a measurement beam are both provided through a single optical fiber. A positive auxiliary lens is placed in the system to give a converging wavefront onto the convex mirror under test. A measurement is taken that includes the aberrations of the convex mirror as well as the errors due to two transmissions through the positive auxiliary lens. A second, measurement provides the information to eliminate this error. A negative lens can also be measured in a similar way. Again, there are two measurement set-ups. A reference beam is provided from a first optical fiber and a measurement beam is provided from a second optical fiber. A positive auxiliary lens is placed in the system to provide a converging wavefront from the reference beam onto the negative lens under test. The measurement beam is combined with the reference wavefront and is analyzed by standard methods. This measurement includes the aberrations of the negative lens, as well as the errors due to a single transmission through the positive auxiliary lens. A second measurement provides the information to eliminate this error.

  4. Application Of The Phase Shifting Diffraction Interferometer For Measuring Convex Mirrors And Negative Lenses

    DOEpatents

    Sommargren, Gary E.; Campbell, Eugene W.

    2005-06-21

    To measure a convex mirror, a reference beam and a measurement beam are both provided through a single optical fiber. A positive auxiliary lens is placed in the system to give a converging wavefront onto the convex mirror under test. A measurement is taken that includes the aberrations of the convex mirror as well as the errors due to two transmissions through the positive auxiliary lens. A second measurement provides the information to eliminate this error. A negative lens can also be measured in a similar way. Again, there are two measurement set-ups. A reference beam is provided from a first optical fiber and a measurement beam is provided from a second optical fiber. A positive auxiliary lens is placed in the system to provide a converging wavefront from the reference beam onto the negative lens under test. The measurement beam is combined with the reference wavefront and is analyzed by standard methods. This measurement includes the aberrations of the negative lens, as well as the errors due to a single transmission through the positive auxiliary lens. A second measurement provides the information to eliminate this error.

  5. A Leapfrog Navigation System

    NASA Astrophysics Data System (ADS)

    Opshaug, Guttorm Ringstad

    There are times and places where conventional navigation systems, such as the Global Positioning System (GPS), are unavailable due to anything from temporary signal occultations to lack of navigation system infrastructure altogether. The goal of the Leapfrog Navigation System (LNS) is to provide localized positioning services for such cases. The concept behind leapfrog navigation is to advance a group of navigation units teamwise into an area of interest. In a practical 2-D case, leapfrogging assumes known initial positions of at least two currently stationary navigation units. Two or more mobile units can then start to advance into the area of interest. The positions of the mobiles are constantly being calculated based on cross-range distance measurements to the stationary units, as well as cross-ranges among the mobiles themselves. At some point the mobile units stop, and the stationary units are released to move. This second team of units (now mobile) can then overtake the first team (now stationary) and travel even further towards the common goal of the group. Since there always is one stationary team, the position of any unit can be referenced back to the initial positions. Thus, LNS provides absolute positioning. I developed navigation algorithms needed to solve leapfrog positions based on cross-range measurements. I used statistical tools to predict how position errors would grow as a function of navigation unit geometry, cross-range measurement accuracy and previous position errors. Using this knowledge I predicted that a 4-unit Leapfrog Navigation System using 100 m baselines and 200 m leap distances could travel almost 15 km before accumulating absolute position errors of 10 m (1sigma). Finally, I built a prototype leapfrog navigation system using 4 GPS transceiver ranging units. I placed the 4 units in the vertices a 10m x 10m square, and leapfrogged the group 20 meters forwards, and then back again (40 m total travel). Average horizontal RMS position errors never exceeded 16 cm during these field tests.

  6. Organizational safety culture and medical error reporting by Israeli nurses.

    PubMed

    Kagan, Ilya; Barnoy, Sivia

    2013-09-01

    To investigate the association between patient safety culture (PSC) and the incidence and reporting rate of medical errors by Israeli nurses. Self-administered structured questionnaires were distributed to a convenience sample of 247 registered nurses enrolled in training programs at Tel Aviv University (response rate = 91%). The questionnaire's three sections examined the incidence of medication mistakes in clinical practice, the reporting rate for these errors, and the participants' views and perceptions of the safety culture in their workplace at three levels (organizational, departmental, and individual performance). Pearson correlation coefficients, t tests, and multiple regression analysis were used to analyze the data. Most nurses encountered medical errors from a daily to a weekly basis. Six percent of the sample never reported their own errors, while half reported their own errors "rarely or sometimes." The level of PSC was positively and significantly correlated with the error reporting rate. PSC, place of birth, error incidence, and not having an academic nursing degree were significant predictors of error reporting, together explaining 28% of variance. This study confirms the influence of an organizational safety climate on readiness to report errors. Senior healthcare executives and managers can make a major impact on safety culture development by creating and promoting a vision and strategy for quality and safety and fostering their employees' motivation to implement improvement programs at the departmental and individual level. A positive, carefully designed organizational safety culture can encourage error reporting by staff and so improve patient safety. © 2013 Sigma Theta Tau International.

  7. Uncertainty in biological monitoring: a framework for data collection and analysis to account for multiple sources of sampling bias

    USGS Publications Warehouse

    Ruiz-Gutierrez, Viviana; Hooten, Melvin B.; Campbell Grant, Evan H.

    2016-01-01

    Biological monitoring programmes are increasingly relying upon large volumes of citizen-science data to improve the scope and spatial coverage of information, challenging the scientific community to develop design and model-based approaches to improve inference.Recent statistical models in ecology have been developed to accommodate false-negative errors, although current work points to false-positive errors as equally important sources of bias. This is of particular concern for the success of any monitoring programme given that rates as small as 3% could lead to the overestimation of the occurrence of rare events by as much as 50%, and even small false-positive rates can severely bias estimates of occurrence dynamics.We present an integrated, computationally efficient Bayesian hierarchical model to correct for false-positive and false-negative errors in detection/non-detection data. Our model combines independent, auxiliary data sources with field observations to improve the estimation of false-positive rates, when a subset of field observations cannot be validated a posteriori or assumed as perfect. We evaluated the performance of the model across a range of occurrence rates, false-positive and false-negative errors, and quantity of auxiliary data.The model performed well under all simulated scenarios, and we were able to identify critical auxiliary data characteristics which resulted in improved inference. We applied our false-positive model to a large-scale, citizen-science monitoring programme for anurans in the north-eastern United States, using auxiliary data from an experiment designed to estimate false-positive error rates. Not correcting for false-positive rates resulted in biased estimates of occupancy in 4 of the 10 anuran species we analysed, leading to an overestimation of the average number of occupied survey routes by as much as 70%.The framework we present for data collection and analysis is able to efficiently provide reliable inference for occurrence patterns using data from a citizen-science monitoring programme. However, our approach is applicable to data generated by any type of research and monitoring programme, independent of skill level or scale, when effort is placed on obtaining auxiliary information on false-positive rates.

  8. Multipath calibration in GPS pseudorange measurements

    NASA Technical Reports Server (NTRS)

    Kee, Changdon (Inventor); Parkinson, Bradford W. (Inventor)

    1998-01-01

    Novel techniques are disclosed for eliminating multipath errors, including mean bias errors, in pseudorange measurements made by conventional global positioning system receivers. By correlating the multipath signals of different satellites at their cross-over points in the sky, multipath mean bias errors are effectively eliminated. By then taking advantage of the geometrical dependence of multipath, a linear combination of spherical harmonics are fit to the satellite multipath data to create a hemispherical model of the multipath. This calibration model can then be used to compensate for multipath in subsequent measurements and thereby obtain GPS positioning to centimeter accuracy.

  9. Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system.

    PubMed

    Ebe, Kazuyu; Sugimoto, Satoru; Utsunomiya, Satoru; Kagamu, Hiroshi; Aoyama, Hidefumi; Court, Laurence; Tokuyama, Katsuichi; Baba, Ryuta; Ogihara, Yoshisada; Ichikawa, Kosuke; Toyama, Joji

    2015-08-01

    To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio-caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient's tumor motion. A substitute target with the patient's tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors' QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients' tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors and gimbal motion errors in the ExacTrac log analyses (n = 13). The newly developed video image-based QA system, including in-house software, can analyze more than a thousand images (33 frames/s). Positional errors are approximately equivalent to those in ExacTrac log analyses. This system is useful for the visual illustration of the progress of the tracking state and for the quantification of positional accuracy during dynamic tumor tracking irradiation in the Vero4DRT system.

  10. Initial clinical experience with a video-based patient positioning system.

    PubMed

    Johnson, L S; Milliken, B D; Hadley, S W; Pelizzari, C A; Haraf, D J; Chen, G T

    1999-08-01

    To report initial clinical experience with an interactive, video-based patient positioning system that is inexpensive, quick, accurate, and easy to use. System hardware includes two black-and-white CCD cameras, zoom lenses, and a PC equipped with a frame grabber. Custom software is used to acquire and archive video images, as well as to display real-time subtraction images revealing patient misalignment in multiple views. Two studies are described. In the first study, video is used to document the daily setup histories of 5 head and neck patients. Time-lapse cine loops are generated for each patient and used to diagnose and correct common setup errors. In the second study, 6 twice-daily (BID) head and neck patients are positioned according to the following protocol: at AM setups conventional treatment room lasers are used; at PM setups lasers are used initially and then video is used for 1-2 minutes to fine-tune the patient position. Lateral video images and lateral verification films are registered off-line to compare the distribution of setup errors per patient, with and without video assistance. In the first study, video images were used to determine the accuracy of our conventional head and neck setup technique, i.e., alignment of lightcast marks and surface anatomy to treatment room lasers and the light field. For this initial cohort of patients, errors ranged from sigma = 5 to 7 mm and were patient-specific. Time-lapse cine loops of the images revealed sources of the error, and as a result, our localization techniques and immobilization device were modified to improve setup accuracy. After the improvements, conventional setup errors were reduced to sigma = 3 to 5 mm. In the second study, when a stereo pair of live subtraction images were introduced to perform daily "on-line" setup correction, errors were reduced to sigma = 1 to 3 mm. Results depended on patient health and cooperation and the length of time spent fine-tuning the position. An interactive, video-based patient positioning system was shown to reduce setup errors to within 1 to 3 mm in head and neck patients, without a significant increase in overall treatment time or labor-intensive procedures. Unlike retrospective portal image analysis, use of two live-video images provides the therapists with immediate feedback and allows for true 3-D positioning and correction of out-of-plane rotation before radiation is delivered. With significant improvement in head and neck alignment and the elimination of setup errors greater than 3 to 5 mm, margins associated with treatment volumes potentially can be reduced, thereby decreasing normal tissue irradiation.

  11. In search of periodic signatures in IGS REPRO1 solution

    NASA Astrophysics Data System (ADS)

    Mtamakaya, J. D.; Santos, M. C.; Craymer, M. R.

    2010-12-01

    We have been looking for periodic signatures in the REPRO1 solution recently released by the IGS. At this stage, a selected sub-set of IGS station time series in position and residual domain are under harmonic analysis. We can learn different things from this analysis. From the position domain, we can learn more about actual station motions. From the residual domain, we can learn more about mis-modelled or un-modelled errors. As far as error sources are concerned, we have investigated effects that may be due to tides, atmospheric loading, definition of the position of the figure axis and GPS constellation geometry. This poster presents and discusses our findings and presents insights on errors that need to be modelled or have their models improved.

  12. Accuracy of linear drilling in temporal bone using drill press system for minimally invasive cochlear implantation

    PubMed Central

    Balachandran, Ramya; Labadie, Robert F.

    2015-01-01

    Purpose A minimally invasive approach for cochlear implantation involves drilling a narrow linear path through the temporal bone from the skull surface directly to the cochlea for insertion of the electrode array without the need for an invasive mastoidectomy. Potential drill positioning errors must be accounted for to predict the effectiveness and safety of the procedure. The drilling accuracy of a system used for this procedure was evaluated in bone surrogate material under a range of clinically relevant parameters. Additional experiments were performed to isolate the error at various points along the path to better understand why deflections occur. Methods An experimental setup to precisely position the drill press over a target was used. Custom bone surrogate test blocks were manufactured to resemble the mastoid region of the temporal bone. The drilling error was measured by creating divots in plastic sheets before and after drilling and using a microscope to localize the divots. Results The drilling error was within the tolerance needed to avoid vital structures and ensure accurate placement of the electrode; however, some parameter sets yielded errors that may impact the effectiveness of the procedure when combined with other error sources. The error increases when the lateral stage of the path terminates in an air cell and when the guide bushings are positioned further from the skull surface. At contact points due to air cells along the trajectory, higher errors were found for impact angles of 45° and higher as well as longer cantilevered drill lengths. Conclusion The results of these experiments can be used to define more accurate and safe drill trajectories for this minimally invasive surgical procedure. PMID:26183149

  13. Accuracy of linear drilling in temporal bone using drill press system for minimally invasive cochlear implantation.

    PubMed

    Dillon, Neal P; Balachandran, Ramya; Labadie, Robert F

    2016-03-01

    A minimally invasive approach for cochlear implantation involves drilling a narrow linear path through the temporal bone from the skull surface directly to the cochlea for insertion of the electrode array without the need for an invasive mastoidectomy. Potential drill positioning errors must be accounted for to predict the effectiveness and safety of the procedure. The drilling accuracy of a system used for this procedure was evaluated in bone surrogate material under a range of clinically relevant parameters. Additional experiments were performed to isolate the error at various points along the path to better understand why deflections occur. An experimental setup to precisely position the drill press over a target was used. Custom bone surrogate test blocks were manufactured to resemble the mastoid region of the temporal bone. The drilling error was measured by creating divots in plastic sheets before and after drilling and using a microscope to localize the divots. The drilling error was within the tolerance needed to avoid vital structures and ensure accurate placement of the electrode; however, some parameter sets yielded errors that may impact the effectiveness of the procedure when combined with other error sources. The error increases when the lateral stage of the path terminates in an air cell and when the guide bushings are positioned further from the skull surface. At contact points due to air cells along the trajectory, higher errors were found for impact angles of [Formula: see text] and higher as well as longer cantilevered drill lengths. The results of these experiments can be used to define more accurate and safe drill trajectories for this minimally invasive surgical procedure.

  14. Why GPS makes distances bigger than they are

    PubMed Central

    Ranacher, Peter; Brunauer, Richard; Trutschnig, Wolfgang; Van der Spek, Stefan; Reich, Siegfried

    2016-01-01

    ABSTRACT Global navigation satellite systems such as the Global Positioning System (GPS) is one of the most important sensors for movement analysis. GPS is widely used to record the trajectories of vehicles, animals and human beings. However, all GPS movement data are affected by both measurement and interpolation errors. In this article we show that measurement error causes a systematic bias in distances recorded with a GPS; the distance between two points recorded with a GPS is – on average – bigger than the true distance between these points. This systematic ‘overestimation of distance’ becomes relevant if the influence of interpolation error can be neglected, which in practice is the case for movement sampled at high frequencies. We provide a mathematical explanation of this phenomenon and illustrate that it functionally depends on the autocorrelation of GPS measurement error (C). We argue that C can be interpreted as a quality measure for movement data recorded with a GPS. If there is a strong autocorrelation between any two consecutive position estimates, they have very similar error. This error cancels out when average speed, distance or direction is calculated along the trajectory. Based on our theoretical findings we introduce a novel approach to determine C in real-world GPS movement data sampled at high frequencies. We apply our approach to pedestrian trajectories and car trajectories. We found that the measurement error in the data was strongly spatially and temporally autocorrelated and give a quality estimate of the data. Most importantly, our findings are not limited to GPS alone. The systematic bias and its implications are bound to occur in any movement data collected with absolute positioning if interpolation error can be neglected. PMID:27019610

  15. SU-E-T-132: Dosimetric Impact of Positioning Errors in Hypo-Fractionated Cranial Radiation Therapy Using Frameless Stereotactic BrainLAB System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keeling, V; Jin, H; Ali, I

    2014-06-01

    Purpose: To determine dosimetric impact of positioning errors in the stereotactic hypo-fractionated treatment of intracranial lesions using 3Dtransaltional and 3D-rotational corrections (6D) frameless BrainLAB ExacTrac X-Ray system. Methods: 20 cranial lesions, treated in 3 or 5 fractions, were selected. An infrared (IR) optical positioning system was employed for initial patient setup followed by stereoscopic kV X-ray radiographs for position verification. 6D-translational and rotational shifts were determined to correct patient position. If these shifts were above tolerance (0.7 mm translational and 1° rotational), corrections were applied and another set of X-rays was taken to verify patient position. Dosimetric impact (D95, Dmin,more » Dmax, and Dmean of planning target volume (PTV) compared to original plans) of positioning errors for initial IR setup (XC: Xray Correction) and post-correction (XV: X-ray Verification) was determined in a treatment planning system using a method proposed by Yue et al. (Med. Phys. 33, 21-31 (2006)) with 3D-translational errors only and 6D-translational and rotational errors. Results: Absolute mean translational errors (±standard deviation) for total 92 fractions (XC/XV) were 0.79±0.88/0.19±0.15 mm (lateral), 1.66±1.71/0.18 ±0.16 mm (longitudinal), 1.95±1.18/0.15±0.14 mm (vertical) and rotational errors were 0.61±0.47/0.17±0.15° (pitch), 0.55±0.49/0.16±0.24° (roll), and 0.68±0.73/0.16±0.15° (yaw). The average changes (loss of coverage) in D95, Dmin, Dmax, and Dmean were 4.5±7.3/0.1±0.2%, 17.8±22.5/1.1±2.5%, 0.4±1.4/0.1±0.3%, and 0.9±1.7/0.0±0.1% using 6Dshifts and 3.1±5.5/0.0±0.1%, 14.2±20.3/0.8±1.7%, 0.0±1.2/0.1±0.3%, and 0.7±1.4/0.0±0.1% using 3D-translational shifts only. The setup corrections (XC-XV) improved the PTV coverage by 4.4±7.3% (D95) and 16.7±23.5% (Dmin) using 6D adjustment. Strong correlations were observed between translation errors and deviations in dose coverage for XC. Conclusion: The initial BrainLAB IR system based on rigidity of the mask-frame setup is not sufficient for accurate stereotactic positioning; however, with X-ray imageguidance sub-millimeter accuracy is achieved with negligible deviations in dose coverage. The angular corrections (mean angle summation=1.84°) are important and cause considerable deviations in dose coverage.« less

  16. Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study.

    PubMed

    Walch, Gilles; Vezeridis, Peter S; Boileau, Pascal; Deransart, Pierric; Chaoui, Jean

    2015-02-01

    Glenoid component positioning is a key factor for success in total shoulder arthroplasty. Three-dimensional (3D) measurements of glenoid retroversion, inclination, and humeral head subluxation are helpful tools for preoperative planning. The purpose of this study was to assess the reliability and precision of a novel surgical method for placing the glenoid component with use of patient-specific templates created by preoperative surgical planning and 3D modeling. A preoperative computed tomography examination of cadaveric scapulae (N = 18) was performed. The glenoid implants were virtually placed, and patient-specific guides were created to direct the guide pin into the desired orientation and position in the glenoid. The 3D orientation and position of the guide pin were evaluated by performing a postoperative computed tomography scan for each scapula. The differences between the preoperative planning and the achieved result were analyzed. The mean error in 3D orientation of the guide pin was 2.39°, the mean entry point position error was 1.05 mm, and the mean inclination angle error was 1.42°. The average error in the version angle was 1.64°. There were no technical difficulties or complications related to use of patient-specific guides for guide pin placement. Quantitative analysis of guide pin positioning demonstrated a good correlation between preoperative planning and the achieved position of the guide pin. This study demonstrates the reliability and precision of preoperative planning software and patient-specific guides for glenoid component placement in total shoulder arthroplasty. Copyright © 2015. Published by Elsevier Inc.

  17. Development of a patient positioning error compensation tool for Korea Heavy-Ion Medical Accelerator Treatment Center

    NASA Astrophysics Data System (ADS)

    Kim, Min-Joo; Suh, Tae-Suk; Cho, Woong; Jung, Won-Gyun

    2015-07-01

    In this study, a potential validation tool for compensating for the patient positioning error was developed by using 2D/3D and 3D/3D image registration. For 2D/3D registration, digitallyreconstructed radiography (DRR) and three-dimensional computed tomography (3D-CT) images were applied. The ray-casting algorithm is the most straightforward method for generating DRR, so we adopted the traditional ray-casting method, which finds the intersections of a ray with all objects, voxels of the 3D-CT volume in the scene. The similarity between the extracted DRR and the orthogonal image was measured by using a normalized mutual information method. Two orthogonal images were acquired from a Cyber-knife system from the anterior-posterior (AP) and right lateral (RL) views. The 3D-CT and the two orthogonal images of an anthropomorphic phantom and of the head and neck of a cancer patient were used in this study. For 3D/3D registration, planning CT and in-room CT images were applied. After registration, the translation and the rotation factors were calculated to position a couch to be movable in six dimensions. Registration accuracies and average errors of 2.12 mm ± 0.50 mm for transformations and 1.23 ° ± 0.40 ° for rotations were acquired by using 2D/3D registration with the anthropomorphic Alderson-Rando phantom. In addition, registration accuracies and average errors of 0.90 mm ± 0.30 mm for transformations and 1.00 ° ± 0.2 ° for rotations were acquired by using CT image sets. We demonstrated that this validation tool could compensate for patient positioning errors. In addition, this research could be a fundamental step in compensating for patient positioning errors at the Korea Heavy-ion Medical Accelerator Treatment Center.

  18. Motivational processes from expectancy-value theory are associated with variability in the error positivity in young children

    PubMed Central

    Kim, Matthew H.; Marulis, Loren M.; Grammer, Jennie K.; Morrison, Frederick J.; Gehring, William J.

    2016-01-01

    Motivational beliefs and values influence how children approach challenging activities. The present study explores motivational processes from an expectancy-value theory framework by studying children's mistakes and their responses to them by focusing on two ERP components, the error-related negativity (ERN) and error positivity (Pe). Motivation was assessed using a child-friendly challenge puzzle task and a brief interview measure prior to ERP testing. Data from 50 four- to six-year-old children revealed that greater perceived competence beliefs were related to a larger Pe, while stronger intrinsic task value beliefs were associated with a smaller Pe. Motivation was unrelated to the ERN. Individual differences in early motivational processes may reflect electrophysiological activity related to conscious error awareness. PMID:27898304

  19. Random errors in interferometry with the least-squares method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Qi

    2011-01-20

    This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships havemore » also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.« less

  20. Early math and reading achievement are associated with the error positivity.

    PubMed

    Kim, Matthew H; Grammer, Jennie K; Marulis, Loren M; Carrasco, Melisa; Morrison, Frederick J; Gehring, William J

    2016-12-01

    Executive functioning (EF) and motivation are associated with academic achievement and error-related ERPs. The present study explores whether early academic skills predict variability in the error-related negativity (ERN) and error positivity (Pe). Data from 113 three- to seven-year-old children in a Go/No-Go task revealed that stronger early reading and math skills predicted a larger Pe. Closer examination revealed that this relation was quadratic and significant for children performing at or near grade level, but not significant for above-average achievers. Early academics did not predict the ERN. These findings suggest that the Pe - which reflects individual differences in motivational processes as well as attention - may be associated with early academic achievement. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. [Medication error management climate and perception for system use according to construction of medication error prevention system].

    PubMed

    Kim, Myoung Soo

    2012-08-01

    The purpose of this cross-sectional study was to examine current status of IT-based medication error prevention system construction and the relationships among system construction, medication error management climate and perception for system use. The participants were 124 patient safety chief managers working for 124 hospitals with over 300 beds in Korea. The characteristics of the participants, construction status and perception of systems (electric pharmacopoeia, electric drug dosage calculation system, computer-based patient safety reporting and bar-code system) and medication error management climate were measured in this study. The data were collected between June and August 2011. Descriptive statistics, partial Pearson correlation and MANCOVA were used for data analysis. Electric pharmacopoeia were constructed in 67.7% of participating hospitals, computer-based patient safety reporting systems were constructed in 50.8%, electric drug dosage calculation systems were in use in 32.3%. Bar-code systems showed up the lowest construction rate at 16.1% of Korean hospitals. Higher rates of construction of IT-based medication error prevention systems resulted in greater safety and a more positive error management climate prevailed. The supportive strategies for improving perception for use of IT-based systems would add to system construction, and positive error management climate would be more easily promoted.

  2. Low Frequency Error Analysis and Calibration for High-Resolution Optical Satellite's Uncontrolled Geometric Positioning

    NASA Astrophysics Data System (ADS)

    Wang, Mi; Fang, Chengcheng; Yang, Bo; Cheng, Yufeng

    2016-06-01

    The low frequency error is a key factor which has affected uncontrolled geometry processing accuracy of the high-resolution optical image. To guarantee the geometric quality of imagery, this paper presents an on-orbit calibration method for the low frequency error based on geometric calibration field. Firstly, we introduce the overall flow of low frequency error on-orbit analysis and calibration, which includes optical axis angle variation detection of star sensor, relative calibration among star sensors, multi-star sensor information fusion, low frequency error model construction and verification. Secondly, we use optical axis angle change detection method to analyze the law of low frequency error variation. Thirdly, we respectively use the method of relative calibration and information fusion among star sensors to realize the datum unity and high precision attitude output. Finally, we realize the low frequency error model construction and optimal estimation of model parameters based on DEM/DOM of geometric calibration field. To evaluate the performance of the proposed calibration method, a certain type satellite's real data is used. Test results demonstrate that the calibration model in this paper can well describe the law of the low frequency error variation. The uncontrolled geometric positioning accuracy of the high-resolution optical image in the WGS-84 Coordinate Systems is obviously improved after the step-wise calibration.

  3. A Vision-Based Self-Calibration Method for Robotic Visual Inspection Systems

    PubMed Central

    Yin, Shibin; Ren, Yongjie; Zhu, Jigui; Yang, Shourui; Ye, Shenghua

    2013-01-01

    A vision-based robot self-calibration method is proposed in this paper to evaluate the kinematic parameter errors of a robot using a visual sensor mounted on its end-effector. This approach could be performed in the industrial field without external, expensive apparatus or an elaborate setup. A robot Tool Center Point (TCP) is defined in the structural model of a line-structured laser sensor, and aligned to a reference point fixed in the robot workspace. A mathematical model is established to formulate the misalignment errors with kinematic parameter errors and TCP position errors. Based on the fixed point constraints, the kinematic parameter errors and TCP position errors are identified with an iterative algorithm. Compared to the conventional methods, this proposed method eliminates the need for a robot-based-frame and hand-to-eye calibrations, shortens the error propagation chain, and makes the calibration process more accurate and convenient. A validation experiment is performed on an ABB IRB2400 robot. An optimal configuration on the number and distribution of fixed points in the robot workspace is obtained based on the experimental results. Comparative experiments reveal that there is a significant improvement of the measuring accuracy of the robotic visual inspection system. PMID:24300597

  4. Effect of atmospheric turbulence on the bit error probability of a space to ground near infrared laser communications link using binary pulse position modulation and an avalanche photodiode detector

    NASA Technical Reports Server (NTRS)

    Safren, H. G.

    1987-01-01

    The effect of atmospheric turbulence on the bit error rate of a space-to-ground near infrared laser communications link is investigated, for a link using binary pulse position modulation and an avalanche photodiode detector. Formulas are presented for the mean and variance of the bit error rate as a function of signal strength. Because these formulas require numerical integration, they are of limited practical use. Approximate formulas are derived which are easy to compute and sufficiently accurate for system feasibility studies, as shown by numerical comparison with the exact formulas. A very simple formula is derived for the bit error rate as a function of signal strength, which requires only the evaluation of an error function. It is shown by numerical calculations that, for realistic values of the system parameters, the increase in the bit error rate due to turbulence does not exceed about thirty percent for signal strengths of four hundred photons per bit or less. The increase in signal strength required to maintain an error rate of one in 10 million is about one or two tenths of a db.

  5. Quantitative assessment of hit detection and confirmation in single and duplicate high-throughput screenings.

    PubMed

    Wu, Zhijin; Liu, Dongmei; Sui, Yunxia

    2008-02-01

    The process of identifying active targets (hits) in high-throughput screening (HTS) usually involves 2 steps: first, removing or adjusting for systematic variation in the measurement process so that extreme values represent strong biological activity instead of systematic biases such as plate effect or edge effect and, second, choosing a meaningful cutoff on the calculated statistic to declare positive compounds. Both false-positive and false-negative errors are inevitable in this process. Common control or estimation of error rates is often based on an assumption of normal distribution of the noise. The error rates in hit detection, especially false-negative rates, are hard to verify because in most assays, only compounds selected in primary screening are followed up in confirmation experiments. In this article, the authors take advantage of a quantitative HTS experiment in which all compounds are tested 42 times over a wide range of 14 concentrations so true positives can be found through a dose-response curve. Using the activity status defined by dose curve, the authors analyzed the effect of various data-processing procedures on the sensitivity and specificity of hit detection, the control of error rate, and hit confirmation. A new summary score is proposed and demonstrated to perform well in hit detection and useful in confirmation rate estimation. In general, adjusting for positional effects is beneficial, but a robust test can prevent overadjustment. Error rates estimated based on normal assumption do not agree with actual error rates, for the tails of noise distribution deviate from normal distribution. However, false discovery rate based on empirically estimated null distribution is very close to observed false discovery proportion.

  6. Learning a visuomotor rotation: simultaneous visual and proprioceptive information is crucial for visuomotor remapping.

    PubMed

    Shabbott, Britne A; Sainburg, Robert L

    2010-05-01

    Visuomotor adaptation is mediated by errors between intended and sensory-detected arm positions. However, it is not clear whether visual-based errors that are shown during the course of motion lead to qualitatively different or more efficient adaptation than errors shown after movement. For instance, continuous visual feedback mediates online error corrections, which may facilitate or inhibit the adaptation process. We addressed this question by manipulating the timing of visual error information and task instructions during a visuomotor adaptation task. Subjects were exposed to a visuomotor rotation, during which they received continuous visual feedback (CF) of hand position with instructions to correct or not correct online errors, or knowledge-of-results (KR), provided as a static hand-path at the end of each trial. Our results showed that all groups improved performance with practice, and that online error corrections were inconsequential to the adaptation process. However, in contrast to the CF groups, the KR group showed relatively small reductions in mean error with practice, increased inter-trial variability during rotation exposure, and more limited generalization across target distances and workspace. Further, although the KR group showed improved performance with practice, after-effects were minimal when the rotation was removed. These findings suggest that simultaneous visual and proprioceptive information is critical in altering neural representations of visuomotor maps, although delayed error information may elicit compensatory strategies to offset perturbations.

  7. Analyzing False Positives of Four Questions in the Force Concept Inventory

    ERIC Educational Resources Information Center

    Yasuda, Jun-ichro; Mae, Naohiro; Hull, Michael M.; Taniguchi, Masa-aki

    2018-01-01

    In this study, we analyze the systematic error from false positives of the Force Concept Inventory (FCI). We compare the systematic errors of question 6 (Q.6), Q.7, and Q.16, for which clearly erroneous reasoning has been found, with Q.5, for which clearly erroneous reasoning has not been found. We determine whether or not a correct response to a…

  8. Technical Note: Millimeter precision in ultrasound based patient positioning: Experimental quantification of inherent technical limitations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ballhausen, Hendrik, E-mail: hendrik.ballhausen@med.uni-muenchen.de; Hieber, Sheila; Li, Minglun

    2014-08-15

    Purpose: To identify the relevant technical sources of error of a system based on three-dimensional ultrasound (3D US) for patient positioning in external beam radiotherapy. To quantify these sources of error in a controlled laboratory setting. To estimate the resulting end-to-end geometric precision of the intramodality protocol. Methods: Two identical free-hand 3D US systems at both the planning-CT and the treatment room were calibrated to the laboratory frame of reference. Every step of the calibration chain was repeated multiple times to estimate its contribution to overall systematic and random error. Optimal margins were computed given the identified and quantified systematicmore » and random errors. Results: In descending order of magnitude, the identified and quantified sources of error were: alignment of calibration phantom to laser marks 0.78 mm, alignment of lasers in treatment vs planning room 0.51 mm, calibration and tracking of 3D US probe 0.49 mm, alignment of stereoscopic infrared camera to calibration phantom 0.03 mm. Under ideal laboratory conditions, these errors are expected to limit ultrasound-based positioning to an accuracy of 1.05 mm radially. Conclusions: The investigated 3D ultrasound system achieves an intramodal accuracy of about 1 mm radially in a controlled laboratory setting. The identified systematic and random errors require an optimal clinical tumor volume to planning target volume margin of about 3 mm. These inherent technical limitations do not prevent clinical use, including hypofractionation or stereotactic body radiation therapy.« less

  9. Direct Measures of Character Mislocalizations with Masked/Unmasked Exposures.

    ERIC Educational Resources Information Center

    Chastain, Garvin; And Others

    Butler (1980) compared errors representing intrusions and mislocalizations on 3x3 letter displays under pattern-mask versus no-mask conditions and found that pattern masking increased character mislocalization errors (naming a character in the display but not in the target position as being the target) over intrusion errors (naming a character not…

  10. The Advantage of the Second Military Survey in Fluvial Measures

    NASA Astrophysics Data System (ADS)

    Kovács, G.

    2009-04-01

    The Second Military Survey of the Habsburg Empire, completed in the 19th century, can be very useful in different scientific investigations owing to its accuracy and data content. The fact, that the mapmakers used geodetic projection, and the high accuracy of the survey guarantee that scientists can use these maps and the represented objects can be evaluated in retrospective studies. Among others, the hydrological information of the map sheets is valuable. The streams were drawn with very thin lines that also ascertain the high accuracy of their location, provided that the geodetic position of the sheet can be constructed with high accuracy. After geocoding these maps we faced the high accuracy of line elements. Not only the location of these lines but the form of the creeks are usually almost the same as recent shape. The goal of our study was the neotectonic evaluation of the western part of the Pannonian Basin, bordered by Pinka, Rába and Répce Rivers. The watercourses, especially alluvial ones, react very sensitively to tectonic forcing. However, the present-day course of the creeks and rivers are mostly regulated, therefore they are unsuitable for such studies. Consequently, the watercourses should be reconstructed from maps surveyed prior to the main water control measures. The Second Military Survey is a perfect source for such studies because it is the first survey has drawn in geodetic projection but the creeks haven't been regulated yet. The maps show intensive agricultural cultivation and silviculture in the study area. Especially grazing cultivation precincts of the streams is important for us. That phenomenon and data from other sources prove that the streams haven't been regulated in that time. The streams were able to meander, and flood its banks, and only natural levees are present. The general morphology south from the Kőszegi Mountains shows typical SSE slopes with low relief cut off by 30-60 meter high scarps followed by streams. That suggested us to investigate the neotectonic features, what also indicated by the alternate meandering of surveyed streams. After geocoding the maps of the area, the streams were digitised, and their sinuosity values were calculated. At places significant difference of sinuosity has been observed along the streams, it can be considered as indicators of differential uplift or subsidence of the bedrock/alluvium. This method can be useful in general, if the watercourses mapped in the historical map are assumed to be unaffected by human.

  11. The use of multibeam backscatter intensity data as a tool for mapping glacial deposits in the Central North Sea, UK

    NASA Astrophysics Data System (ADS)

    Stewart, Heather; Bradwell, Tom

    2014-05-01

    Multibeam backscatter intensity data acquired offshore eastern Scotland and north-eastern England have been used to map drumlin fields, large arcuate moraine ridges, smaller scale moraine ridges, and incised channels on the sea floor. The study area includes the catchments of the previously proposed, but only partly mapped, Strathmore, Forth-Tay, and Tweed palaeo-ice streams. The ice sheet glacial landsystem is extremely well preserved on the sea bed and comprehensive mapping of the seafloor geomorphology has been undertaken. The authors demonstrate the value in utilising not only digital terrain models (both NEXTMap and multibeam bathymetry derived) in undertaking geomorphological mapping, but also examining the backscatter intensity data that is often overlooked. Backscatter intensity maps were generated using FM Geocoder by the British Geological Survey. FM Geocoder corrects the backscatter intensities registered by the multibeam echosounder system, and then geometrically corrects and positions each acoustic sample in a backscatter mosaic. The backscatter intensity data were gridded at the best resolution per dataset (between 2 and 5 m). The strength of the backscattering is dependent upon sediment type, grain size, survey conditions, sea-bed roughness, compaction and slope. A combination of manual interpretation and semi-automated classification of the backscatter intensity data (a predictive method for mapping variations in surficial sea-bed sediments) has been undertaken in the study area. The combination of the two methodologies has produced a robust glacial geomorphological map for the study area. Four separate drumlin fields have been mapped in the study area indicative of fast-flowing and persistent ice-sheet flow configurations. A number of individual drumlins are also identified located outside the fields. The drumlins show as areas of high backscatter intensity compared to the surrounding sea bed, indicating the drumlins comprise mixed sediments of gravelly sands and sandy gravels compared to the surrounding sandy and muddy sediments. Moraines are indicated as areas of high backscatter intensity and comprise coarse grained sediments. A range of moraine sizes have been identified from large scale moraines reflecting both frontal still stands or re-advances of the ice-sheet margin, de geer moraines and smaller moraines that may represent annual variations. Meltwater channels and tunnel valleys are revealed as areas of low backscatter intensity reflecting post-glacial soft sediment infill of the depressions incised into coarser grained and higher strength glacial deposits by these features.

  12. Sharing knowledge of Planetary Datasets through the Web-Based PRoGIS

    NASA Astrophysics Data System (ADS)

    Giordano, M. G.; Morley, J. M.; Muller, J. P. M.; Barnes, R. B.; Tao, Y. T.

    2015-10-01

    The large amount of raw and derived data available from various planetary surface missions (e.g. Mars and Moon in our case) has been integrated withco-registered and geocoded orbital image data to provide rover traverses and camera site locations in universal global co-ordinates [1]. This then allows an integrated GIS to use these geocoded products for scientific applications: we aim to create a web interface, PRoGIS, with minimal controls focusing on the usability and visualisation of the data, to allow planetary geologists to share annotated surface observations. These observations in a common context are shared between different tools and software (PRoGIS, Pro3D, 3D point cloud viewer). Our aim is to use only Open Source components that integrate Open Web Services for planetary data to make available an universal platform with a WebGIS interface, as well as a 3D point cloud and a Panorama viewer to explore derived data. On top of these tools we are building capabilities to make and share annotations amongst users. We use Python and Django for the server-side framework and Open Layers 3 for the WebGIS client. For good performance previewing 3D data (point clouds, pictures on the surface and panoramas) we employ ThreeJS, a WebGL Javascript library. Additionally, user and group controls allow scientists to store and share their observations. PRoGIS not only displays data but also launches sophisticated 3D vision reprocessing (PRoVIP) and an immersive 3D analysis environment (PRo3D).

  13. Utilizing GIS Technology to Improve Fire Prevention Activities in an Urban Fire Department.

    PubMed

    Shields, Wendy C; Shields, Timothy M; McDonald, Eileen M; Perry, Elise C; Hanna, Peter; Gielen, Andrea C

    2015-01-01

    The Baltimore City Fire Department (BCFD) has been installing smoke alarms city wide for more than three decades. Though data on each visit are entered into a database, no system existed for using these data for planning or evaluation. The objective of this study is to use Geographic Information System (GIS) technology and existing databases to 1) determine the number of residences in need of a home visit; 2) determine total visits, visits per household, and number of homes entered for eligible households; and 3) demonstrate integration of various data via GIS for use in prevention planning. The tax assessment database was queried to determine the number of eligible (as determined by BCFD policy) residences in need of a visit. Each attempted BCFD home visit was coded to identify, if the BCFD personnel interacted with residents ("pass door") and installed alarms. Home visits were geocoded and compared to the tax assessment database to determine city wide pass door rates. Frequency of visits was run by individual residences to measure efficiency. A total of 206,850 residences met BCFD eligibility for a home visit. In 2007, the BCFD attempted 181,757 home visits and 177,213 were successfully geocoded to 122,118 addresses. A total of 122,118 eligible residences (59%) received a home visit. A total of 35,317 residences (29%) received a repeat visit attempt. The pass door rate was 22% (46,429) of all residences. GIS technology offers a promising means for fire departments to plan and evaluate the fire prevention services they provide.

  14. An unsupervised classification method for inferring original case locations from low-resolution disease maps.

    PubMed

    Brownstein, John S; Cassa, Christopher A; Kohane, Isaac S; Mandl, Kenneth D

    2006-12-08

    Widespread availability of geographic information systems software has facilitated the use of disease mapping in academia, government and private sector. Maps that display the address of affected patients are often exchanged in public forums, and published in peer-reviewed journal articles. As previously reported, a search of figure legends in five major medical journals found 19 articles from 1994-2004 that identify over 19,000 patient addresses. In this report, a method is presented to evaluate whether patient privacy is being breached in the publication of low-resolution disease maps. To demonstrate the effect, a hypothetical low-resolution map of geocoded patient addresses was created and the accuracy with which patient addresses can be resolved is described. Through georeferencing and unsupervised classification of the original image, the method precisely re-identified 26% (144/550) of the patient addresses from a presentation quality map and 79% (432/550) from a publication quality map. For the presentation quality map, 99.8% of the addresses were within 70 meters (approximately one city block length) of the predicted patient location, 51.6% of addresses were identified within five buildings, 70.7% within ten buildings and 93% within twenty buildings. For the publication quality map, all addresses were within 14 meters and 11 buildings of the predicted patient location. This study demonstrates that lowering the resolution of a map displaying geocoded patient addresses does not sufficiently protect patient addresses from re-identification. Guidelines to protect patient privacy, including those of medical journals, should reflect policies that ensure privacy protection when spatial data are displayed or published.

  15. Measuring women's cumulative neighborhood deprivation exposure using longitudinally linked vital records: a method for life course MCH research.

    PubMed

    Kramer, Michael R; Dunlop, Anne L; Hogue, Carol J R

    2014-02-01

    A life course conceptual framework for MCH research demands new tools for understanding population health and measuring exposures. We propose a method for measuring population-based socio-environmental trajectories for women of reproductive age. We merged maternal longitudinally-linked births to Georgia-resident women from 1994 to 2007 with census economic and social measures using residential geocodes to create woman-centered socio-environmental trajectories. We calculated a woman's neighborhood deprivation index (NDI) at the time of each of her births and, from these, we calculated a cumulative NDI. We fit Loess curves to describe average life course NDI trajectories and binomial regression models to test specific life course theory hypotheses relating cumulative NDI to risk for preterm birth. Of the 1,815,944 total live births, we linked 1,000,437 live births to 413,048 unique women with two or more births. Record linkage had high specificity but relatively low sensitivity which appears non-differential with respect to maternal characteristics. Georgia women on average experienced upward mobility across the life course, although differences by race, early life neighborhood quality, and age at first birth produced differences in cumulative NDI. Adjusted binomial models found evidence for modification of the effect of history of prior preterm birth and advancing age on risk for preterm birth by cumulative NDI. The creation of trajectories from geocoded maternal longitudinally-linked vital records is one method to carry out life course MCH research. We discuss approaches for investigating the impact of truncation of the life course, selection bias from migration, and misclassification of cumulative exposure.

  16. Residential Proximity to Heavy-Traffic Roads, Benzene Exposure, and Childhood Leukemia-The GEOCAP Study, 2002-2007.

    PubMed

    Houot, Jennifer; Marquant, Fabienne; Goujon, Stéphanie; Faure, Laure; Honoré, Cécile; Roth, Marie-Hélène; Hémon, Denis; Clavel, Jacqueline

    2015-10-15

    Childhood leukemia may be associated with traffic-related environmental exposure to benzene, and additional data are needed. The Géolocalisation des Cancers Pédiatriques (GEOCAP) Study, a nationwide French case-control study, was designed to avoid selection bias due to differential participation and misclassification. The study compared the 2,760 childhood leukemia cases diagnosed in France between 2002 and 2007 (including 2,275 cases of acute lymphoblastic leukemia (ALL) and 418 cases of acute myeloblastic leukemia (AML)) with 30,000 contemporaneous child population controls. The residence addresses were precisely geocoded, and 3 indicators of residential proximity to traffic were considered. Estimates of benzene concentrations were also available for the Île-de-France region (including Paris). A 300-m increase in major road length within 150 m of the geocoded address was significantly associated with AML (odds ratio = 1.2, 95% confidence interval: 1.0, 1.4) but not with ALL (odds ratio = 1.0, 95% confidence interval: 0.9, 1.1), and the association was reinforced in the Île-de-France region when this indicator was combined with benzene estimates. These results, which were free from any participation bias and based on objectively determined indices of exposure, showed an increased incidence of AML associated with heavy-traffic road density near a child's home. The results support a role for traffic-related benzene exposure in the etiology of childhood AML. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Drug-related deaths and the sales of needles through pharmacies

    PubMed Central

    Davidson, Peter J.; Martinez, Alexis; Lutnick, Alexandra; Kral, Alex H.; Bluthenthal, Ricky N.

    2014-01-01

    Background Providing needles to people who inject drugs is a well-proven public health response to the transmission of HIV and other blood borne viruses. Despite over a quarter of a century of research, new concerns about potential unintended negative consequences of needle distribution continue to emerge. Specifically, a claim was recently made that the introduction of pharmacy sales of needles was followed by an increase in overdoses in pharmacy parking lots. If true, this would have serious implications for the design of needle access programs, particularly those involving pharmacy sales of needles. Methods We examine spatial relationships between drug-related deaths and pharmacies in Los Angeles County (population 9·8 million) before and after the 2007 enactment of a California law allowing pharmacy sales of needles without a prescription. 7,049 drug related deaths occurred in Los Angeles county from 2000-2009 inclusive. 4,275 of these deaths could be geocoded, and were found to be clustered at the census tract level. Results We used three methods to examine spatial relationships between overdose death locations and pharmacy locations for two years on either side of the enactment of the pharmacy sales law, and found no statistically significant changes. Among the 711 geocodable deaths occurring in the two years following the change in law, no death was found to occur within 50 meters of a pharmacy which sold needles. Conclusion These results are consistent with prior studies which suggest pharmacy sales of needles improve access to needles without causing increased harms to the surrounding community. PMID:25499730

  18. Drug-related deaths and the sales of needles through pharmacies.

    PubMed

    Davidson, Peter J; Martinez, Alexis; Lutnick, Alexandra; Kral, Alex H; Bluthenthal, Ricky N

    2015-02-01

    Providing needles to people who inject drugs is a well-proven public health response to the transmission of HIV and other blood borne viruses. Despite over a quarter of a century of research, new concerns about potential unintended negative consequences of needle distribution continue to emerge. Specifically, a claim was recently made that the introduction of pharmacy sales of needles was followed by an increase in overdoses in pharmacy parking lots. If true, this would have serious implications for the design of needle access programs, particularly those involving pharmacy sales of needles. We examine spatial relationships between drug-related deaths and pharmacies in Los Angeles County (population 9.8 million) before and after the 2007 enactment of a California law allowing pharmacy sales of needles without a prescription. Seven thousand and forty-nine drugs related deaths occurred in Los Angeles county from 2000 to 2009 inclusive. Four thousand two hundred and seventy-five of these deaths could be geocoded, and were found to be clustered at the census tract level. We used three methods to examine spatial relationships between overdose death locations and pharmacy locations for two years on either side of the enactment of the pharmacy sales law, and found no statistically significant changes. Among the 711 geocodable deaths occurring in the two years following the change in law, no death was found to occur within 50m of a pharmacy which sold needles. These results are consistent with prior studies which suggest pharmacy sales of needles improve access to needles without causing increased harms to the surrounding community. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Implementation of an experimental program to investigate the performance characteristics of OMEGA navigation

    NASA Technical Reports Server (NTRS)

    Baxa, E. G., Jr.

    1974-01-01

    A theoretical formulation of differential and composite OMEGA error is presented to establish hypotheses about the functional relationships between various parameters and OMEGA navigational errors. Computer software developed to provide for extensive statistical analysis of the phase data is described. Results from the regression analysis used to conduct parameter sensitivity studies on differential OMEGA error tend to validate the theoretically based hypothesis concerning the relationship between uncorrected differential OMEGA error and receiver separation range and azimuth. Limited results of measurement of receiver repeatability error and line of position measurement error are also presented.

  20. A method for automatic feature points extraction of human vertebrae three-dimensional model

    NASA Astrophysics Data System (ADS)

    Wu, Zhen; Wu, Junsheng

    2017-05-01

    A method for automatic extraction of the feature points of the human vertebrae three-dimensional model is presented. Firstly, the statistical model of vertebrae feature points is established based on the results of manual vertebrae feature points extraction. Then anatomical axial analysis of the vertebrae model is performed according to the physiological and morphological characteristics of the vertebrae. Using the axial information obtained from the analysis, a projection relationship between the statistical model and the vertebrae model to be extracted is established. According to the projection relationship, the statistical model is matched with the vertebrae model to get the estimated position of the feature point. Finally, by analyzing the curvature in the spherical neighborhood with the estimated position of feature points, the final position of the feature points is obtained. According to the benchmark result on multiple test models, the mean relative errors of feature point positions are less than 5.98%. At more than half of the positions, the error rate is less than 3% and the minimum mean relative error is 0.19%, which verifies the effectiveness of the method.

  1. A new scheme of force reflecting control

    NASA Technical Reports Server (NTRS)

    Kim, Won S.

    1992-01-01

    A new scheme of force reflecting control has been developed that incorporates position-error-based force reflection and robot compliance control. The operator is provided with a kinesthetic force feedback which is proportional to the position error between the operator-commanded and the actual position of the robot arm. Robot compliance control, which increases the effective compliance of the robot, is implemented by low pass filtering the outputs of the force/torque sensor mounted on the base of robot hand and using these signals to alter the operator's position command. This position-error-based force reflection scheme combined with shared compliance control has been implemented successfully to the Advanced Teleoperation system consisting of dissimilar master-slave arms. Stability measurements have demonstrated unprecedentedly high force reflection gains of up to 2 or 3, even though the slave arm is much stiffer than operator's hand holding the force reflecting hand controller. Peg-in-hole experiments were performed with eight different operating modes to evaluate the new force-reflecting control scheme. Best task performance resulted with this new control scheme.

  2. Theory of mind in schizophrenia: error types and associations with symptoms.

    PubMed

    Fretland, Ragnhild A; Andersson, Stein; Sundet, Kjetil; Andreassen, Ole A; Melle, Ingrid; Vaskinn, Anja

    2015-03-01

    Social cognition is an important determinant of functioning in schizophrenia. However, how social cognition relates to the clinical symptoms of schizophrenia is still unclear. The aim of this study was to explore the relationship between a social cognition domain, Theory of Mind (ToM), and the clinical symptoms of schizophrenia. Specifically, we investigated the associations between three ToM error types; 1) "overmentalizing" 2) "reduced ToM and 3) "no ToM", and positive, negative and disorganized symptoms. Fifty-two participants with a diagnosis of schizophrenia or schizoaffective disorder were assessed with the Movie for the Assessment of Social Cognition (MASC), a video-based ToM measure. An empirically validated five-factor model of the Positive and Negative Syndrome Scale (PANSS) was used to assess clinical symptoms. There was a significant, small-moderate association between overmentalizing and positive symptoms (rho=.28, p=.04). Disorganized symptoms correlated at a trend level with "reduced ToM" (rho=.27, p=.05). There were no other significant correlations between ToM impairments and symptom levels. Positive/disorganized symptoms did not contribute significantly in explaining total ToM performance, whereas IQ did (B=.37, p=.01). Within the undermentalizing domain, participants performed more "reduced ToM" errors than "no ToM" errors. Overmentalizing was associated with positive symptoms. The undermentalizing error types were unrelated to symptoms, but "reduced ToM" was somewhat associated to disorganization. The higher number of "reduced ToM" responses suggests that schizophrenia is characterized by accuracy problems rather than a fundamental lack of mental state concept. The findings call for the use of more sensitive measures when investigating ToM in schizophrenia to avoid the "right/wrong ToM"-dichotomy. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Response cost, reinforcement, and children's Porteus Maze qualitative performance.

    PubMed

    Neenan, D M; Routh, D K

    1986-09-01

    Sixty fourth-grade children were given two different series of the Porteus Maze Test. The first series was given as a baseline, and the second series was administered under one of four different experimental conditions: control, response cost, positive reinforcement, or negative verbal feedback. Response cost and positive reinforcement, but not negative verbal feedback, led to significant decreases in the number of all types of qualitative errors in relation to the control group. The reduction of nontargeted as well as targeted errors provides evidence for the generalized effects of response cost and positive reinforcement.

  4. HUMAN EYE OPTICS: Determination of positions of optical elements of the human eye

    NASA Astrophysics Data System (ADS)

    Galetskii, S. O.; Cherezova, T. Yu

    2009-02-01

    An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm.

  5. A open loop guidance architecture for navigationally robust on-orbit docking

    NASA Technical Reports Server (NTRS)

    Chern, Hung-Sheng

    1995-01-01

    The development of an open-hop guidance architecture is outlined for autonomous rendezvous and docking (AR&D) missions to determine whether the Global Positioning System (GPS) can be used in place of optical sensors for relative initial position determination of the chase vehicle. Feasible command trajectories for one, two, and three impulse AR&D maneuvers are determined using constrained trajectory optimization. Early AR&D command trajectory results suggest that docking accuracies are most sensitive to vertical position errors at the initial conduction of the chase vehicle. Thus, a feasible command trajectory is based on maximizing the size of the locus of initial vertical positions for which a fixed sequence of impulses will translate the chase vehicle into the target while satisfying docking accuracy requirements. Documented accuracies are used to determine whether relative GPS can achieve the vertical position error requirements of the impulsive command trajectories. Preliminary development of a thruster management system for the Cargo Transfer Vehicle (CTV) based on optimal throttle settings is presented to complete the guidance architecture. Results show that a guidance architecture based on a two impulse maneuvers generated the best performance in terms of initial position error and total velocity change for the chase vehicle.

  6. Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kapanen, Mika; Department of Medical Physics, Tampere University Hospital; Laaksomaa, Marko, E-mail: Marko.Laaksomaa@pshp.fi

    2016-04-01

    Residual position errors of the lymph node (LN) surrogates and humeral head (HH) were determined for 2 different arm fixation devices in radiotherapy (RT) of breast cancer: a standard wrist-hold (WH) and a house-made rod-hold (RH). The effect of arm position correction (APC) based on setup images was also investigated. A total of 113 consecutive patients with early-stage breast cancer with LN irradiation were retrospectively analyzed (53 and 60 using the WH and RH, respectively). Residual position errors of the LN surrogates (Th1-2 and clavicle) and the HH were investigated to compare the 2 fixation devices. The position errors andmore » setup margins were determined before and after the APC to investigate the efficacy of the APC in the treatment situation. A threshold of 5 mm was used for the residual errors of the clavicle and Th1-2 to perform the APC, and a threshold of 7 mm was used for the HH. The setup margins were calculated with the van Herk formula. Irradiated volumes of the HH were determined from RT treatment plans. With the WH and the RH, setup margins up to 8.1 and 6.7 mm should be used for the LN surrogates, and margins up to 4.6 and 3.6 mm should be used to spare the HH, respectively, without the APC. After the APC, the margins of the LN surrogates were equal to or less than 7.5/6.0 mm with the WH/RH, but margins up to 4.2/2.9 mm were required for the HH. The APC was needed at least once with both the devices for approximately 60% of the patients. With the RH, irradiated volume of the HH was approximately 2 times more than with the WH, without any dose constraints. Use of the RH together with the APC resulted in minimal residual position errors and setup margins for all the investigated bony landmarks. Based on the obtained results, we prefer the house-made RH. However, more attention should be given to minimize the irradiation of the HH with the RH than with the WH.« less

  7. Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vedam, S.; Docef, A.; Fix, M.

    2005-06-15

    The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response necessitates predictive models of respiratory tumor motion to synchronize radiation delivery. Predicting a complex process such as respiratory motion introduces geometric errors, which have been reported in several publications. However, the dosimetric effect of such errors on 4D radiation delivery has not yet been investigated. Thus, our aim in this work was to quantify the dosimetric effectsmore » of geometric error due to prediction under several different conditions. Conformal and intensity modulated radiation therapy (IMRT) plans for a lung patient were generated for anterior-posterior/posterior-anterior (AP/PA) beam arrangements at 6 and 18 MV energies to provide planned dose distributions. Respiratory motion data was obtained from 60 diaphragm-motion fluoroscopy recordings from five patients. A linear adaptive filter was employed to predict the tumor position. The geometric error of prediction was defined as the absolute difference between predicted and actual positions at each diaphragm position. Distributions of geometric error of prediction were obtained for all of the respiratory motion data. Planned dose distributions were then convolved with distributions for the geometric error of prediction to obtain convolved dose distributions. The dosimetric effect of such geometric errors was determined as a function of several variables: response time (0-0.6 s), beam energy (6/18 MV), treatment delivery (3D/4D), treatment type (conformal/IMRT), beam direction (AP/PA), and breathing training type (free breathing/audio instruction/visual feedback). Dose difference and distance-to-agreement analysis was employed to quantify results. Based on our data, the dosimetric impact of prediction (a) increased with response time, (b) was larger for 3D radiation therapy as compared with 4D radiation therapy, (c) was relatively insensitive to change in beam energy and beam direction, (d) was greater for IMRT distributions as compared with conformal distributions, (e) was smaller than the dosimetric impact of latency, and (f) was greatest for respiration motion with audio instructions, followed by visual feedback and free breathing. Geometric errors of prediction that occur during 4D radiation delivery introduce dosimetric errors that are dependent on several factors, such as response time, treatment-delivery type, and beam energy. Even for relatively small response times of 0.6 s into the future, dosimetric errors due to prediction could approach delivery errors when respiratory motion is not accounted for at all. To reduce the dosimetric impact, better predictive models and/or shorter response times are required.« less

  8. Formal Verification of Safety Buffers for Sate-Based Conflict Detection and Resolution

    NASA Technical Reports Server (NTRS)

    Herencia-Zapana, Heber; Jeannin, Jean-Baptiste; Munoz, Cesar A.

    2010-01-01

    The information provided by global positioning systems is never totally exact, and there are always errors when measuring position and velocity of moving objects such as aircraft. This paper studies the effects of these errors in the actual separation of aircraft in the context of state-based conflict detection and resolution. Assuming that the state information is uncertain but that bounds on the errors are known, this paper provides an analytical definition of a safety buffer and sufficient conditions under which this buffer guarantees that actual conflicts are detected and solved. The results are presented as theorems, which were formally proven using a mechanical theorem prover.

  9. Confirmation bias in human reinforcement learning: Evidence from counterfactual feedback processing

    PubMed Central

    Lefebvre, Germain; Blakemore, Sarah-Jayne

    2017-01-01

    Previous studies suggest that factual learning, that is, learning from obtained outcomes, is biased, such that participants preferentially take into account positive, as compared to negative, prediction errors. However, whether or not the prediction error valence also affects counterfactual learning, that is, learning from forgone outcomes, is unknown. To address this question, we analysed the performance of two groups of participants on reinforcement learning tasks using a computational model that was adapted to test if prediction error valence influences learning. We carried out two experiments: in the factual learning experiment, participants learned from partial feedback (i.e., the outcome of the chosen option only); in the counterfactual learning experiment, participants learned from complete feedback information (i.e., the outcomes of both the chosen and unchosen option were displayed). In the factual learning experiment, we replicated previous findings of a valence-induced bias, whereby participants learned preferentially from positive, relative to negative, prediction errors. In contrast, for counterfactual learning, we found the opposite valence-induced bias: negative prediction errors were preferentially taken into account, relative to positive ones. When considering valence-induced bias in the context of both factual and counterfactual learning, it appears that people tend to preferentially take into account information that confirms their current choice. PMID:28800597

  10. Confirmation bias in human reinforcement learning: Evidence from counterfactual feedback processing.

    PubMed

    Palminteri, Stefano; Lefebvre, Germain; Kilford, Emma J; Blakemore, Sarah-Jayne

    2017-08-01

    Previous studies suggest that factual learning, that is, learning from obtained outcomes, is biased, such that participants preferentially take into account positive, as compared to negative, prediction errors. However, whether or not the prediction error valence also affects counterfactual learning, that is, learning from forgone outcomes, is unknown. To address this question, we analysed the performance of two groups of participants on reinforcement learning tasks using a computational model that was adapted to test if prediction error valence influences learning. We carried out two experiments: in the factual learning experiment, participants learned from partial feedback (i.e., the outcome of the chosen option only); in the counterfactual learning experiment, participants learned from complete feedback information (i.e., the outcomes of both the chosen and unchosen option were displayed). In the factual learning experiment, we replicated previous findings of a valence-induced bias, whereby participants learned preferentially from positive, relative to negative, prediction errors. In contrast, for counterfactual learning, we found the opposite valence-induced bias: negative prediction errors were preferentially taken into account, relative to positive ones. When considering valence-induced bias in the context of both factual and counterfactual learning, it appears that people tend to preferentially take into account information that confirms their current choice.

  11. Performance Evaluation and Requirements Assessment for Gravity Gradient Referenced Navigation

    PubMed Central

    Lee, Jisun; Kwon, Jay Hyoun; Yu, Myeongjong

    2015-01-01

    In this study, simulation tests for gravity gradient referenced navigation (GGRN) are conducted to verify the effects of various factors such as database (DB) and sensor errors, flight altitude, DB resolution, initial errors, and measurement update rates on the navigation performance. Based on the simulation results, requirements for GGRN are established for position determination with certain target accuracies. It is found that DB and sensor errors and flight altitude have strong effects on the navigation performance. In particular, a DB and sensor with accuracies of 0.1 E and 0.01 E, respectively, are required to determine the position more accurately than or at a level similar to the navigation performance of terrain referenced navigation (TRN). In most cases, the horizontal position error of GGRN is less than 100 m. However, the navigation performance of GGRN is similar to or worse than that of a pure inertial navigation system when the DB and sensor errors are 3 E or 5 E each and the flight altitude is 3000 m. Considering that the accuracy of currently available gradiometers is about 3 E or 5 E, GGRN does not show much advantage over TRN at present. However, GGRN is expected to exhibit much better performance in the near future when accurate DBs and gravity gradiometer are available. PMID:26184212

  12. Compensation for loads during arm movements using equilibrium-point control.

    PubMed

    Gribble, P L; Ostry, D J

    2000-12-01

    A significant problem in motor control is how information about movement error is used to modify control signals to achieve desired performance. A potential source of movement error and one that is readily controllable experimentally relates to limb dynamics and associated movement-dependent loads. In this paper, we have used a position control model to examine changes to control signals for arm movements in the context of movement-dependent loads. In the model, based on the equilibrium-point hypothesis, equilibrium shifts are adjusted directly in proportion to the positional error between desired and actual movements. The model is used to simulate multi-joint movements in the presence of both "internal" loads due to joint interaction torques, and externally applied loads resulting from velocity-dependent force fields. In both cases it is shown that the model can achieve close correspondence to empirical data using a simple linear adaptation procedure. An important feature of the model is that it achieves compensation for loads during movement without the need for either coordinate transformations between positional error and associated corrective forces, or inverse dynamics calculations.

  13. A SEASAT SASS simulation experiment to quantify the errors related to a + or - 3 hour intermittent assimilation technique

    NASA Technical Reports Server (NTRS)

    Sylvester, W. B.

    1984-01-01

    A series of SEASAT repeat orbits over a sequence of best Low center positions is simulated by using the Seatrak satellite calculator. These Low centers are, upon appropriate interpolation to hourly positions, Located at various times during the + or - 3 hour assimilation cycle. Error analysis for a sample of best cyclone center positions taken from the Atlantic and Pacific oceans reveals a minimum average error of 1.1 deg of Longitude and a standard deviation of 0.9 deg of Longitude. The magnitude of the average error seems to suggest that by utilizing the + or - 3 hour window in the assimilation cycle, the quality of the SASS data is degraded to the Level of the background. A further consequence of this assimilation scheme is the effect which is manifested as a result of the blending of two or more more juxtaposed vector winds, generally possessing different properties (vector quantity and time). The outcome of this is to reduce gradients in the wind field and to deform isobaric and frontal patterns of the intial field.

  14. [Memorization of Sequences of Movements of the Right and the Left Hand by Right- and Left-Handers].

    PubMed

    Bobrova, E V; Bogacheva, I N; Lyakhovetskii, V A; Fabinskaja, A A; Fomina, E V

    2015-01-01

    We analyzed the errors of right- and left-handers when performing memorized sequences by the left or the right hand during the task which activates positional coding: after 6-10 times the order of movements changed (the positions remained the same during all task). The task was first performed by one ("initial") hand, and then by another one ("continuing"); there were 2 groups of right-handers and 2 groups of left-handers. It was found that the pattern of errors during the task performance by the initial hand is similar in right- and left-handers both for the dominant and non-dominant hand. The information about the previous positions after changing the order of elements is used in the sequences for subdominant hands and not used in the sequences for dominant ones. After changing the hand, right- and left-handers show different patterns of errors ("non-symmetrical"). Thus, the errors of right- and left-handers are "symmetrical" at the early stages of task performance, while the transfer of this motor skill in right-and left-handers occurs in different ways.

  15. Motivational state controls the prediction error in Pavlovian appetitive-aversive interactions.

    PubMed

    Laurent, Vincent; Balleine, Bernard W; Westbrook, R Frederick

    2018-01-01

    Contemporary theories of learning emphasize the role of a prediction error signal in driving learning, but the nature of this signal remains hotly debated. Here, we used Pavlovian conditioning in rats to investigate whether primary motivational and emotional states interact to control prediction error. We initially generated cues that positively or negatively predicted an appetitive food outcome. We then assessed how these cues modulated aversive conditioning when a novel cue was paired with a foot shock. We found that a positive predictor of food enhances, whereas a negative predictor of that same food impairs, aversive conditioning. Critically, we also showed that the enhancement produced by the positive predictor is removed by reducing the value of its associated food. In contrast, the impairment triggered by the negative predictor remains insensitive to devaluation of its associated food. These findings provide compelling evidence that the motivational value attributed to a predicted food outcome can directly control appetitive-aversive interactions and, therefore, that motivational processes can modulate emotional processes to generate the final error term on which subsequent learning is based. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Synergies in Astrometry: Predicting Navigational Error of Visual Binary Stars

    NASA Astrophysics Data System (ADS)

    Gessner Stewart, Susan

    2015-08-01

    Celestial navigation can employ a number of bright stars which are in binary systems. Often these are unresolved, appearing as a single, center-of-light object. A number of these systems are, however, in wide systems which could introduce a margin of error in the navigation solution if not handled properly. To illustrate the importance of good orbital solutions for binary systems - as well as good astrometry in general - the relationship between the center-of-light versus individual catalog position of celestial bodies and the error in terrestrial position derived via celestial navigation is demonstrated. From the list of navigational binary stars, fourteen such binary systems with at least 3.0 arcseconds apparent separation are explored. Maximum navigational error is estimated under the assumption that the bright star in the pair is observed at maximum separation, but the center-of-light is employed in the navigational solution. The relationships between navigational error and separation, orbital periods, and observers' latitude are discussed.

  17. Characterization of the International Linear Collider damping ring optics

    NASA Astrophysics Data System (ADS)

    Shanks, J.; Rubin, D. L.; Sagan, D.

    2014-10-01

    A method is presented for characterizing the emittance dilution and dynamic aperture for an arbitrary closed lattice that includes guide field magnet errors, multipole errors and misalignments. This method, developed and tested at the Cornell Electron Storage Ring Test Accelerator (CesrTA), has been applied to the damping ring lattice for the International Linear Collider (ILC). The effectiveness of beam based emittance tuning is limited by beam position monitor (BPM) measurement errors, number of corrector magnets and their placement, and correction algorithm. The specifications for damping ring magnet alignment, multipole errors, number of BPMs, and precision in BPM measurements are shown to be consistent with the required emittances and dynamic aperture. The methodology is then used to determine the minimum number of position monitors that is required to achieve the emittance targets, and how that minimum depends on the location of the BPMs. Similarly, the maximum tolerable multipole errors are evaluated. Finally, the robustness of each BPM configuration with respect to random failures is explored.

  18. A service evaluation of on-line image-guided radiotherapy to lower extremity sarcoma: Investigating the workload implications of a 3 mm action level for image assessment and correction prior to delivery.

    PubMed

    Taylor, C; Parker, J; Stratford, J; Warren, M

    2018-05-01

    Although all systematic and random positional setup errors can be corrected for in entirety during on-line image-guided radiotherapy, the use of a specified action level, below which no correction occurs, is also an option. The following service evaluation aimed to investigate the use of this 3 mm action level for on-line image assessment and correction (online, systematic set-up error and weekly evaluation) for lower extremity sarcoma, and understand the impact on imaging frequency and patient positioning error within one cancer centre. All patients were immobilised using a thermoplastic shell attached to a plastic base and an individual moulded footrest. A retrospective analysis of 30 patients was performed. Patient setup and correctional data derived from cone beam CT analysis was retrieved. The timing, frequency and magnitude of corrections were evaluated. The population systematic and random error was derived. 20% of patients had no systematic corrections over the duration of treatment, and 47% had one. The maximum number of systematic corrections per course of radiotherapy was 4, which occurred for 2 patients. 34% of episodes occurred within the first 5 fractions. All patients had at least one observed translational error during their treatment greater than 0.3 cm, and 80% of patients had at least one observed translational error during their treatment greater than 0.5 cm. The population systematic error was 0.14 cm, 0.10 cm, 0.14 cm and random error was 0.27 cm, 0.22 cm, 0.23 cm in the lateral, caudocranial and anteroposterial directions. The required Planning Target Volume margin for the study population was 0.55 cm, 0.41 cm and 0.50 cm in the lateral, caudocranial and anteroposterial directions. The 3 mm action level for image assessment and correction prior to delivery reduced the imaging burden and focussed intervention on patients that exhibited greater positional variability. This strategy could be an efficient deployment of departmental resources if full daily correction of positional setup error is not possible. Copyright © 2017. Published by Elsevier Ltd.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chengqiang, L; Yin, Y; Chen, L

    Purpose: To investigate the impact of MLC position errors on simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for patients with nasopharyngeal carcinoma. Methods: To compare the dosimetric differences between the simulated plans and the clinical plans, ten patients with locally advanced NPC treated with SIB-IMRT were enrolled in this study. All plans were calculated with an inverse planning system (Pinnacle3, Philips Medical System{sub )}. Random errors −2mm to 2mm{sub )},shift errors{sub (} 2mm,1mm and 0.5mm) and systematic extension/ contraction errors (±2mm, ±1mm and ±0.5mm) of the MLC leaf position were introduced respectively into the original plans to create the simulated plans.more » Dosimetry factors were compared between the original and the simulated plans. Results: The dosimetric impact of the random and system shift errors of MLC position was insignificant within 2mm, the maximum changes in D95% of PGTV,PTV1,PTV2 were-0.92±0.51%,1.00±0.24% and 0.62±0.17%, the maximum changes in the D0.1cc of spinal cord and brainstem were 1.90±2.80% and −1.78±1.42%, the maximum changes in the Dmean of parotids were1.36±1.23% and −2.25±2.04%.However,the impact of MLC extension or contraction errors was found significant. For 2mm leaf extension errors, the average changes in D95% of PGTV,PTV1,PTV2 were 4.31±0.67%,4.29±0.65% and 4.79±0.82%, the averaged value of the D0.1cc to spinal cord and brainstem were increased by 7.39±5.25% and 6.32±2.28%,the averaged value of the mean dose to left and right parotid were increased by 12.75±2.02%,13.39±2.17% respectively. Conclusion: The dosimetric effect was insignificant for random MLC leaf position errors up to 2mm. There was a high sensitivity to dose distribution for MLC extension or contraction errors.We should pay attention to the anatomic changes in target organs and anatomical structures during the course,individual radiotherapy was recommended to ensure adaptive doses.« less

  20. Cognitive errors: thinking clearly when it could be child maltreatment.

    PubMed

    Laskey, Antoinette L

    2014-10-01

    Cognitive errors have been studied in a broad array of fields, including medicine. The more that is understood about how the human mind processes complex information, the more it becomes clear that certain situations are particularly susceptible to less than optimal outcomes because of these errors. This article explores how some of the known cognitive errors may influence the diagnosis of child abuse, resulting in both false-negative and false-positive diagnoses. Suggested remedies for these errors are offered. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Methods and Apparatus for Reducing Multipath Signal Error Using Deconvolution

    NASA Technical Reports Server (NTRS)

    Kumar, Rajendra (Inventor); Lau, Kenneth H. (Inventor)

    1999-01-01

    A deconvolution approach to adaptive signal processing has been applied to the elimination of signal multipath errors as embodied in one preferred embodiment in a global positioning system receiver. The method and receiver of the present invention estimates then compensates for multipath effects in a comprehensive manner. Application of deconvolution, along with other adaptive identification and estimation techniques, results in completely novel GPS (Global Positioning System) receiver architecture.

  2. Feature Positioning on Google Street View Panoramas

    NASA Astrophysics Data System (ADS)

    Tsai, V. J. D.; Chang, C.-T.

    2012-07-01

    Location-based services (LBS) on web-based maps and images have come into real-time since Google launched its Street View imaging services in 2007. This research employs Google Maps API and Web Service, GAE for JAVA, AJAX, Proj4js, CSS and HTML in developing an internet platform for accessing the orientation parameters of Google Street View (GSV) panoramas in order to determine the three dimensional position of interest features that appear on two overlapping panoramas by geometric intersection. A pair of GSV panoramas was examined using known points located on the Library Building of National Chung Hsing University (NCHU) with the root-mean-squared errors of ±0.522m, ±1.230m, and ±5.779m for intersection and ±0.142m, ±1.558m, and ±5.733m for resection in X, Y, and h (elevation), respectively. Potential error sources in GSV positioning were analyzed and illustrated that the errors in Google provided GSV positional parameters dominate the errors in geometric intersection. The developed system is suitable for data collection in establishing LBS applications integrated with Google Maps and Google Earth in traffic sign and infrastructure inventory by adding automatic extraction and matching techniques for points of interest (POI) from GSV panoramas.

  3. Calibration of the motor-assisted robotic stereotaxy system: MARS.

    PubMed

    Heinig, Maximilian; Hofmann, Ulrich G; Schlaefer, Alexander

    2012-11-01

    The motor-assisted robotic stereotaxy system presents a compact and light-weight robotic system for stereotactic neurosurgery. Our system is designed to position probes in the human brain for various applications, for example, deep brain stimulation. It features five fully automated axes. High positioning accuracy is of utmost importance in robotic neurosurgery. First, the key parameters of the robot's kinematics are determined using an optical tracking system. Next, the positioning errors at the center of the arc--which is equivalent to the target position in stereotactic interventions--are investigated using a set of perpendicular cameras. A modeless robot calibration method is introduced and evaluated. To conclude, the application accuracy of the robot is studied in a phantom trial. We identified the bending of the arc under load as the robot's main error source. A calibration algorithm was implemented to compensate for the deflection of the robot's arc. The mean error after the calibration was 0.26 mm, the 68.27th percentile was 0.32 mm, and the 95.45th was 0.50 mm. The kinematic properties of the robot were measured, and based on the results an appropriate calibration method was derived. With mean errors smaller than currently used mechanical systems, our results show that the robot's accuracy is appropriate for stereotactic interventions.

  4. Error properties of Argos satellite telemetry locations using least squares and Kalman filtering.

    PubMed

    Boyd, Janice D; Brightsmith, Donald J

    2013-01-01

    Study of animal movements is key for understanding their ecology and facilitating their conservation. The Argos satellite system is a valuable tool for tracking species which move long distances, inhabit remote areas, and are otherwise difficult to track with traditional VHF telemetry and are not suitable for GPS systems. Previous research has raised doubts about the magnitude of position errors quoted by the satellite service provider CLS. In addition, no peer-reviewed publications have evaluated the usefulness of the CLS supplied error ellipses nor the accuracy of the new Kalman filtering (KF) processing method. Using transmitters hung from towers and trees in southeastern Peru, we show the Argos error ellipses generally contain <25% of the true locations and therefore do not adequately describe the true location errors. We also find that KF processing does not significantly increase location accuracy. The errors for both LS and KF processing methods were found to be lognormally distributed, which has important repercussions for error calculation, statistical analysis, and data interpretation. In brief, "good" positions (location codes 3, 2, 1, A) are accurate to about 2 km, while 0 and B locations are accurate to about 5-10 km. However, due to the lognormal distribution of the errors, larger outliers are to be expected in all location codes and need to be accounted for in the user's data processing. We evaluate five different empirical error estimates and find that 68% lognormal error ellipses provided the most useful error estimates. Longitude errors are larger than latitude errors by a factor of 2 to 3, supporting the use of elliptical error ellipses. Numerous studies over the past 15 years have also found fault with the CLS-claimed error estimates yet CLS has failed to correct their misleading information. We hope this will be reversed in the near future.

  5. Motivational processes from expectancy-value theory are associated with variability in the error positivity in young children.

    PubMed

    Kim, Matthew H; Marulis, Loren M; Grammer, Jennie K; Morrison, Frederick J; Gehring, William J

    2017-03-01

    Motivational beliefs and values influence how children approach challenging activities. The current study explored motivational processes from an expectancy-value theory framework by studying children's mistakes and their responses to them by focusing on two event-related potential (ERP) components: the error-related negativity (ERN) and the error positivity (Pe). Motivation was assessed using a child-friendly challenge puzzle task and a brief interview measure prior to ERP testing. Data from 50 4- to 6-year-old children revealed that greater perceived competence beliefs were related to a larger Pe, whereas stronger intrinsic task value beliefs were associated with a smaller Pe. Motivation was unrelated to the ERN. Individual differences in early motivational processes may reflect electrophysiological activity related to conscious error awareness. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Comparison of the learning curves of digital examination and transabdominal sonography for the determination of fetal head position during labor.

    PubMed

    Rozenberg, P; Porcher, R; Salomon, L J; Boirot, F; Morin, C; Ville, Y

    2008-03-01

    To evaluate the learning curve of transabdominal sonography for the determination of fetal head position in labor and to compare it with that of digital vaginal examination. A student midwife who had never performed digital vaginal examination or ultrasound examination was recruited for this study. Instructions on how to perform digital vaginal examination and ultrasound examination were given before and after completing the first vaginal and ultrasound examinations, and repeated for each subsequent examination for as long as necessary. Digital and ultrasound diagnoses of the fetal head position were always performed first by the student midwife, and repeated by an experienced midwife or physician. The learning curve for identification of the fetal head position by either one of the two methods was analyzed using the cumulative sums (CUSUM) method for measurement errors. One hundred patients underwent digital vaginal examination and 99 had transabdominal sonography for the determination of fetal head position. An error rate of around 50% for vaginal examination was nearly constant during the first 50 examinations. It decreased subsequently, to stabilize at a low level from the 82(nd) patient. Errors of +/- 180 degrees were the most frequent. The learning curve for ultrasound imaging stabilized earlier than that of vaginal examination, after the 32(nd) patient. The most frequent errors with ultrasound examination were the inability to conclude on a diagnosis, particularly at the beginning of training, followed by errors of +/- 45 degrees. Based on our findings for the student tested, learning and accuracy of the determination of fetal head position in labor were easier and higher, respectively, with transabdominal sonography than with digital examination. This should encourage physicians to introduce clinical ultrasound examination into their practice. CUSUM charts provide a reliable representation of the learning curve, by accumulating evidence of performance. Copyright (c) 2008 ISUOG. Published by John Wiley & Sons, Ltd.

  7. A Noninvasive Body Setup Method for Radiotherapy by Using a Multimodal Image Fusion Technique

    PubMed Central

    Zhang, Jie; Chen, Yunxia; Wang, Chenchen; Chu, Kaiyue; Jin, Jianhua; Huang, Xiaolin; Guan, Yue; Li, Weifeng

    2017-01-01

    Purpose: To minimize the mismatch error between patient surface and immobilization system for tumor location by a noninvasive patient setup method. Materials and Methods: The method, based on a point set registration, proposes a shift for patient positioning by integrating information of the computed tomography scans and that of optical surface landmarks. An evaluation of the method included 3 areas: (1) a validation on a phantom by estimating 100 known mismatch errors between patient surface and immobilization system. (2) Five patients with pelvic tumors were considered. The tumor location errors of the method were measured using the difference between the proposal shift of cone-beam computed tomography and that of our method. (3) The collected setup data from the evaluation of patients were compared with the published performance data of other 2 similar systems. Results: The phantom verification results showed that the method was capable of estimating mismatch error between patient surface and immobilization system in a precision of <0.22 mm. For the pelvic tumor, the method had an average tumor location error of 1.303, 2.602, and 1.684 mm in left–right, anterior–posterior, and superior–inferior directions, respectively. The performance comparison with other 2 similar systems suggested that the method had a better positioning accuracy for pelvic tumor location. Conclusion: By effectively decreasing an interfraction uncertainty source (mismatch error between patient surface and immobilization system) in radiotherapy, the method can improve patient positioning precision for pelvic tumor. PMID:29333959

  8. The Frame Constraint on Experimentally Elicited Speech Errors in Japanese

    ERIC Educational Resources Information Center

    Saito, Akie; Inoue, Tomoyoshi

    2017-01-01

    The so-called syllable position effect in speech errors has been interpreted as reflecting constraints posed by the frame structure of a given language, which is separately operating from linguistic content during speech production. The effect refers to the phenomenon that when a speech error occurs, replaced and replacing sounds tend to be in the…

  9. Accuracy and Precision of a Veterinary Neuronavigation System for Radiation Oncology Positioning

    PubMed Central

    Ballegeer, Elizabeth A.; Frey, Stephen; Sieffert, Rob

    2018-01-01

    Conformal radiation treatment plans such as IMRT and other radiosurgery techniques require very precise patient positioning, typically within a millimeter of error for best results. CT cone beam, real-time navigation, and infrared position sensors are potential options for success but rarely present in veterinary radiation centers. A neuronavigation system (Brainsight Vet, Rogue Research) was tested 22 times on a skull for positioning accuracy and precision analysis. The first 6 manipulations allowed the authors to become familiar with the system but were still included in the analyses. Overall, the targeting mean error in 3D was 1.437 mm with SD 1.242 mm. This system could be used for positioning for radiation therapy or radiosurgery. PMID:29666822

  10. Position sense at the human forearm in the horizontal plane during loading and vibration of elbow muscles

    PubMed Central

    Ansems, G E; Allen, T J; Proske, U

    2006-01-01

    When blindfolded subjects match the position of their forearms in the vertical plane they rely on signals coming from the periphery as well as from the central motor command. The command signal provides a positional cue from the accompanying effort sensation required to hold the arm against gravity. Here we have asked, does a centrally generated effort signal contribute to position sense in the horizontal plane, where gravity cannot play a role? Blindfolded subjects were required to match forearm position for the unloaded arm and when flexors or extensors were bearing 10%, 25% or 40% of maximum loads. Before each match the reference arm was conditioned by contracting elbow muscles while the arm was held flexed or extended. For the unloaded arm conditioning led to a consistent pattern of errors which was attributed to signals from flexor and extensor muscle spindles. When elbow muscles were loaded the errors from conditioning converged, presumably because the spindles had become coactivated through the fusimotor system during the load-bearing contraction. However, this convergence was seen only when subjects supported a static load. When they moved the load differences in errors from conditioning persisted. Muscle vibration during load bearing or moving a load did not alter the distribution of errors. It is concluded that for position sense of an unloaded arm in the horizontal plane the brain relies on signals from muscle spindles. When the arm is loaded, an additional signal of central origin contributes, but only if the load is moved. PMID:16873408

  11. Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ebe, Kazuyu, E-mail: nrr24490@nifty.com; Tokuyama, Katsuichi; Baba, Ryuta

    Purpose: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Methods: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio–caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on themore » target phantom during a reproduction of the patient’s tumor motion. A substitute target with the patient’s tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors’ QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients’ tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Results: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors and gimbal motion errors in the ExacTrac log analyses (n = 13). Conclusions: The newly developed video image-based QA system, including in-house software, can analyze more than a thousand images (33 frames/s). Positional errors are approximately equivalent to those in ExacTrac log analyses. This system is useful for the visual illustration of the progress of the tracking state and for the quantification of positional accuracy during dynamic tumor tracking irradiation in the Vero4DRT system.« less

  12. The Greenwich Photo-heliographic Results (1874 - 1976): Initial Corrections to the Printed Publications

    NASA Astrophysics Data System (ADS)

    Erwin, E. H.; Coffey, H. E.; Denig, W. F.; Willis, D. M.; Henwood, R.; Wild, M. N.

    2013-11-01

    A new sunspot and faculae digital dataset for the interval 1874 - 1955 has been prepared under the auspices of the NOAA National Geophysical Data Center (NGDC). This digital dataset contains measurements of the positions and areas of both sunspots and faculae published initially by the Royal Observatory, Greenwich, and subsequently by the Royal Greenwich Observatory (RGO), under the title Greenwich Photo-heliographic Results ( GPR) , 1874 - 1976. Quality control (QC) procedures based on logical consistency have been used to identify the more obvious errors in the RGO publications. Typical examples of identifiable errors are North versus South errors in specifying heliographic latitude, errors in specifying heliographic (Carrington) longitude, errors in the dates and times, errors in sunspot group numbers, arithmetic errors in the summation process, and the occasional omission of solar ephemerides. Although the number of errors in the RGO publications is remarkably small, an initial table of necessary corrections is provided for the interval 1874 - 1917. Moreover, as noted in the preceding companion papers, the existence of two independently prepared digital datasets, which both contain information on sunspot positions and areas, makes it possible to outline a preliminary strategy for the development of an even more accurate digital dataset. Further work is in progress to generate an extremely reliable sunspot digital dataset, based on the long programme of solar observations supported first by the Royal Observatory, Greenwich, and then by the Royal Greenwich Observatory.

  13. Finite Time Control Design for Bilateral Teleoperation System With Position Synchronization Error Constrained.

    PubMed

    Yang, Yana; Hua, Changchun; Guan, Xinping

    2016-03-01

    Due to the cognitive limitations of the human operator and lack of complete information about the remote environment, the work performance of such teleoperation systems cannot be guaranteed in most cases. However, some practical tasks conducted by the teleoperation system require high performances, such as tele-surgery needs satisfactory high speed and more precision control results to guarantee patient' health status. To obtain some satisfactory performances, the error constrained control is employed by applying the barrier Lyapunov function (BLF). With the constrained synchronization errors, some high performances, such as, high convergence speed, small overshoot, and an arbitrarily predefined small residual constrained synchronization error can be achieved simultaneously. Nevertheless, like many classical control schemes only the asymptotic/exponential convergence, i.e., the synchronization errors converge to zero as time goes infinity can be achieved with the error constrained control. It is clear that finite time convergence is more desirable. To obtain a finite-time synchronization performance, the terminal sliding mode (TSM)-based finite time control method is developed for teleoperation system with position error constrained in this paper. First, a new nonsingular fast terminal sliding mode (NFTSM) surface with new transformed synchronization errors is proposed. Second, adaptive neural network system is applied for dealing with the system uncertainties and the external disturbances. Third, the BLF is applied to prove the stability and the nonviolation of the synchronization errors constraints. Finally, some comparisons are conducted in simulation and experiment results are also presented to show the effectiveness of the proposed method.

  14. Automatic detection of MLC relative position errors for VMAT using the EPID-based picket fence test

    NASA Astrophysics Data System (ADS)

    Christophides, Damianos; Davies, Alex; Fleckney, Mark

    2016-12-01

    Multi-leaf collimators (MLCs) ensure the accurate delivery of treatments requiring complex beam fluences like intensity modulated radiotherapy and volumetric modulated arc therapy. The purpose of this work is to automate the detection of MLC relative position errors  ⩾0.5 mm using electronic portal imaging device-based picket fence tests and compare the results to the qualitative assessment currently in use. Picket fence tests with and without intentional MLC errors were measured weekly on three Varian linacs. The picket fence images analysed covered a time period ranging between 14-20 months depending on the linac. An algorithm was developed that calculated the MLC error for each leaf-pair present in the picket fence images. The baseline error distributions of each linac were characterised for an initial period of 6 months and compared with the intentional MLC errors using statistical metrics. The distributions of median and one-sample Kolmogorov-Smirnov test p-value exhibited no overlap between baseline and intentional errors and were used retrospectively to automatically detect MLC errors in routine clinical practice. Agreement was found between the MLC errors detected by the automatic method and the fault reports during clinical use, as well as interventions for MLC repair and calibration. In conclusion the method presented provides for full automation of MLC quality assurance, based on individual linac performance characteristics. The use of the automatic method has been shown to provide early warning for MLC errors that resulted in clinical downtime.

  15. The deficit of joint position sense in the chronic unstable ankle as measured by inversion angle replication error.

    PubMed

    Nakasa, Tomoyuki; Fukuhara, Kohei; Adachi, Nobuo; Ochi, Mitsuo

    2008-05-01

    Functional instability is defined as a repeated ankle inversion sprain and a giving way sensation. Previous studies have described the damage of sensori-motor control in ankle sprain as being a possible cause of functional instability. The aim of this study was to evaluate the inversion angle replication errors in patients with functional instability after ankle sprain. The difference between the index angle and replication angle was measured in 12 subjects with functional instability, with the aim of evaluating the replication error. As a control group, the replication errors of 17 healthy volunteers were investigated. The side-to-side differences of the replication errors were compared between both the groups, and the relationship between the side-to-side differences of the replication errors and the mechanical instability were statistically analyzed in the unstable group. The side-to-side difference of the replication errors was 1.0 +/- 0.7 degrees in the unstable group and 0.2 +/- 0.7 degrees in the control group. There was a statistically significant difference between both the groups. The side-to-side differences of the replication errors in the unstable group did not statistically correlate to the anterior talar translation and talar tilt. The patients with functional instability had the deficit of joint position sense in comparison with healthy volunteers. The replication error did not correlate to the mechanical instability. The patients with functional instability should be treated appropriately in spite of having less mechanical instability.

  16. A vision-based end-point control for a two-link flexible manipulator. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Obergfell, Klaus

    1991-01-01

    The measurement and control of the end-effector position of a large two-link flexible manipulator are investigated. The system implementation is described and an initial algorithm for static end-point positioning is discussed. Most existing robots are controlled through independent joint controllers, while the end-effector position is estimated from the joint positions using a kinematic relation. End-point position feedback can be used to compensate for uncertainty and structural deflections. Such feedback is especially important for flexible robots. Computer vision is utilized to obtain end-point position measurements. A look-and-move control structure alleviates the disadvantages of the slow and variable computer vision sampling frequency. This control structure consists of an inner joint-based loop and an outer vision-based loop. A static positioning algorithm was implemented and experimentally verified. This algorithm utilizes the manipulator Jacobian to transform a tip position error to a joint error. The joint error is then used to give a new reference input to the joint controller. The convergence of the algorithm is demonstrated experimentally under payload variation. A Landmark Tracking System (Dickerson, et al 1990) is used for vision-based end-point measurements. This system was modified and tested. A real-time control system was implemented on a PC and interfaced with the vision system and the robot.

  17. Researchermap: a tool for visualizing author locations using Google maps.

    PubMed

    Rastegar-Mojarad, Majid; Bales, Michael E; Yu, Hong

    2013-01-01

    We hereby present ResearcherMap, a tool to visualize locations of authors of scholarly papers. In response to a query, the system returns a map of author locations. To develop the system we first populated a database of author locations, geocoding institution locations for all available institutional affiliation data in our database. The database includes all authors of Medline papers from 1990 to 2012. We conducted a formative heuristic usability evaluation of the system and measured the system's accuracy and performance. The accuracy of finding the accurate address is 97.5% in our system.

  18. Impacts of Satellite Orbit and Clock on Real-Time GPS Point and Relative Positioning.

    PubMed

    Shi, Junbo; Wang, Gaojing; Han, Xianquan; Guo, Jiming

    2017-06-12

    Satellite orbit and clock corrections are always treated as known quantities in GPS positioning models. Therefore, any error in the satellite orbit and clock products will probably cause significant consequences for GPS positioning, especially for real-time applications. Currently three types of satellite products have been made available for real-time positioning, including the broadcast ephemeris, the International GNSS Service (IGS) predicted ultra-rapid product, and the real-time product. In this study, these three predicted/real-time satellite orbit and clock products are first evaluated with respect to the post-mission IGS final product, which demonstrates cm to m level orbit accuracies and sub-ns to ns level clock accuracies. Impacts of real-time satellite orbit and clock products on GPS point and relative positioning are then investigated using the P3 and GAMIT software packages, respectively. Numerical results show that the real-time satellite clock corrections affect the point positioning more significantly than the orbit corrections. On the contrary, only the real-time orbit corrections impact the relative positioning. Compared with the positioning solution using the IGS final product with the nominal orbit accuracy of ~2.5 cm, the real-time broadcast ephemeris with ~2 m orbit accuracy provided <2 cm relative positioning error for baselines no longer than 216 km. As for the baselines ranging from 574 to 2982 km, the cm-dm level positioning error was identified for the relative positioning solution using the broadcast ephemeris. The real-time product could result in <5 mm relative positioning accuracy for baselines within 2982 km, slightly better than the predicted ultra-rapid product.

  19. Cross-sectional study of area-level disadvantage and glycaemic-related risk in community health service users in the Southern.IML Research (SIMLR) cohort.

    PubMed

    Cross, Roger; Bonney, Andrew; Mayne, Darren J; Weston, Kathryn M

    2017-09-19

    Objectives The aim of the present study was to determine the association between area-level socioeconomic disadvantage and glycaemic-related risk in health service users in the Illawarra-Shoalhaven region of New South Wales, Australia. Methods HbA1c values recorded between 2010 and 2012 for non-pregnant individuals aged ≥18 years were extracted from the Southern.IML Research (SIMLR) database. Individuals were assigned quintiles of the Socioeconomic Indices for Australia (SEIFA) Index of Relative Socioeconomic Disadvantage (IRSD) according to their Statistical Area 1 of residence. Glycaemic risk categories were defined as HbA1c 5.0-5.99% (lowest risk), 6.0-7.49% (intermediate risk) and ≥7.5% (highest risk). Logistic regression models were fit with glycaemic risk category as the outcome variable and IRSD as the study variable, adjusting for age and sex. Results Data from 29064 individuals were analysed. Higher disadvantage was associated with belonging to a higher glycaemic risk category in the fully adjusted model (most disadvantaged vs least disadvantaged quintile; odds ratio 1.74, 95% confidence interval 1.58, 1.93; P<0.001). Conclusion In this geocoded clinical dataset, area-level socioeconomic disadvantage was a significant correlate of increased glycaemic-related risk. Geocoded clinical data can inform more targeted use of health service resources, with the potential for improved health care equity and cost-effectiveness. What is known about the topic? The rapid increase in the prevalence of Type 2 diabetes (T2D), both globally and nationally within Australia, is a major concern for the community and public health agencies. Individual socioeconomic disadvantage is a known risk factor for abnormal glucose metabolism (AGM), including T2D. Although small-area-level socioeconomic disadvantage is a known correlate of AGM in Australia, less is known of the association of area-level disadvantage and glycaemic-related risk in individuals with AGM. What does this paper add? This study demonstrates a robust association between small-area-level socioeconomic disadvantage and glycaemic-related risk in regional New South Wales. The study demonstrates that it is feasible to use geocoded, routinely collected clinical data to identify communities at increased health risk. What are the implications for practitioners? The identification of at-risk populations is an essential step towards targeted public health policy and programs aimed at reducing the burden of AGM, its complications and the associated economic costs. Collaboration between primary care and public health in the collection and use of data described in the present study has the potential to enhance the effectiveness of both sectors.

  20. Hyperspectral Data Processing and Mapping of Soil Parameters: Preliminary Data from Tuscany (Italy)

    NASA Astrophysics Data System (ADS)

    Garfagnoli, F.; Moretti, S.; Catani, F.; Innocenti, L.; Chiarantini, L.

    2010-12-01

    Hyperspectral imaging has become a very powerful remote sensing tool for its capability of performing chemical and physical analysis of the observed areas. The objective of this study is to retrieve and characterize clay mineral content of the cultivated layer of soils, from both airborne hyperspectral and field spectrometry surveys in the 400-2500 nm spectral range. Correlation analysis is used to examine the possibility to predict the selected property using high-resolution reflectance spectra and images. The study area is located in the Mugello basin, about 30 km north of Firenze (Tuscany, Italy). Agriculturally suitable terrains are assigned mainly to annual crops, marginally to olive groves, vineyards and orchards. Soils mostly belong to Regosols and Cambisols orders. About 80 topsoil samples scattered all over the area were collected simultaneously with the flight of SIM.GA hyperspectral camera from Selex Galileo. The quantitative determination of clay minerals content in soil samples was performed by means of XRD and Rietveld refinement. An ASD FieldSpec spectroradiometer was used to obtain reflectance spectra from dried, crushed and sieved samples under controlled laboratory conditions. Different chemometric techniques (multiple linear regression, vertex component analysis, partial least squares regression and band depth analysis) were preliminarily tested to correlate mineralogical records with reflectance data. A one component partial least squares regression model yielded a preliminary R2 value of 0.65. A similar result was achieved by plotting the absorption peak depth at 2210 versus total clay mineral content (band-depth analysis). A complete hyperspectral geocoded reflectance dataset was collected using SIM.GA hyperspectral image sensor from Selex-Galileo, mounted on board of the University of Firenze ultra light aircraft. The approximate pixel resolution was 0.6 m (VNIR) and 1.2 m (SWIR). Airborne SIM.GA row data were firstly transformed into at-sensor radiance values, where calibration coefficients and parameters from laboratory measurements are applied to non-georeferred VNIR/SWIR DN values. Then, geocoded products are retrieved for each flight line by using a procedure developed in IDL Language and PARGE (PARametric Geocoding) software. When all compensation parameters are applied to hyperspectral data or to the final thematic map, orthorectified, georeferred and coregistered VNIR to SWIR images or maps are available for GIS application and 3D view. Airborne imagery has to be corrected for the influence of the atmosphere, solar illumination, sensor viewing geometry and terrain geometry information, for the retrieval of inherent surface reflectance properties. Then, different geophysical parameters can be investigated and retrieved by means of inversion algorithms. The experimental fitting of laboratory data on mineral content is used for airborne data inversion, whose results are in agreement with laboratory records, demonstrating the possibility to use this methodology for digital mapping of soil properties.

  1. Asymmetric generalization in adaptation to target displacement errors in humans and in a neural network model.

    PubMed

    Westendorff, Stephanie; Kuang, Shenbing; Taghizadeh, Bahareh; Donchin, Opher; Gail, Alexander

    2015-04-01

    Different error signals can induce sensorimotor adaptation during visually guided reaching, possibly evoking different neural adaptation mechanisms. Here we investigate reach adaptation induced by visual target errors without perturbing the actual or sensed hand position. We analyzed the spatial generalization of adaptation to target error to compare it with other known generalization patterns and simulated our results with a neural network model trained to minimize target error independent of prediction errors. Subjects reached to different peripheral visual targets and had to adapt to a sudden fixed-amplitude displacement ("jump") consistently occurring for only one of the reach targets. Subjects simultaneously had to perform contralateral unperturbed saccades, which rendered the reach target jump unnoticeable. As a result, subjects adapted by gradually decreasing reach errors and showed negative aftereffects for the perturbed reach target. Reach errors generalized to unperturbed targets according to a translational rather than rotational generalization pattern, but locally, not globally. More importantly, reach errors generalized asymmetrically with a skewed generalization function in the direction of the target jump. Our neural network model reproduced the skewed generalization after adaptation to target jump without having been explicitly trained to produce a specific generalization pattern. Our combined psychophysical and simulation results suggest that target jump adaptation in reaching can be explained by gradual updating of spatial motor goal representations in sensorimotor association networks, independent of learning induced by a prediction-error about the hand position. The simulations make testable predictions about the underlying changes in the tuning of sensorimotor neurons during target jump adaptation. Copyright © 2015 the American Physiological Society.

  2. Evaluation of genomic high-throughput sequencing data generated on Illumina HiSeq and Genome Analyzer systems

    PubMed Central

    2011-01-01

    Background The generation and analysis of high-throughput sequencing data are becoming a major component of many studies in molecular biology and medical research. Illumina's Genome Analyzer (GA) and HiSeq instruments are currently the most widely used sequencing devices. Here, we comprehensively evaluate properties of genomic HiSeq and GAIIx data derived from two plant genomes and one virus, with read lengths of 95 to 150 bases. Results We provide quantifications and evidence for GC bias, error rates, error sequence context, effects of quality filtering, and the reliability of quality values. By combining different filtering criteria we reduced error rates 7-fold at the expense of discarding 12.5% of alignable bases. While overall error rates are low in HiSeq data we observed regions of accumulated wrong base calls. Only 3% of all error positions accounted for 24.7% of all substitution errors. Analyzing the forward and reverse strands separately revealed error rates of up to 18.7%. Insertions and deletions occurred at very low rates on average but increased to up to 2% in homopolymers. A positive correlation between read coverage and GC content was found depending on the GC content range. Conclusions The errors and biases we report have implications for the use and the interpretation of Illumina sequencing data. GAIIx and HiSeq data sets show slightly different error profiles. Quality filtering is essential to minimize downstream analysis artifacts. Supporting previous recommendations, the strand-specificity provides a criterion to distinguish sequencing errors from low abundance polymorphisms. PMID:22067484

  3. Asymmetric generalization in adaptation to target displacement errors in humans and in a neural network model

    PubMed Central

    Westendorff, Stephanie; Kuang, Shenbing; Taghizadeh, Bahareh; Donchin, Opher

    2015-01-01

    Different error signals can induce sensorimotor adaptation during visually guided reaching, possibly evoking different neural adaptation mechanisms. Here we investigate reach adaptation induced by visual target errors without perturbing the actual or sensed hand position. We analyzed the spatial generalization of adaptation to target error to compare it with other known generalization patterns and simulated our results with a neural network model trained to minimize target error independent of prediction errors. Subjects reached to different peripheral visual targets and had to adapt to a sudden fixed-amplitude displacement (“jump”) consistently occurring for only one of the reach targets. Subjects simultaneously had to perform contralateral unperturbed saccades, which rendered the reach target jump unnoticeable. As a result, subjects adapted by gradually decreasing reach errors and showed negative aftereffects for the perturbed reach target. Reach errors generalized to unperturbed targets according to a translational rather than rotational generalization pattern, but locally, not globally. More importantly, reach errors generalized asymmetrically with a skewed generalization function in the direction of the target jump. Our neural network model reproduced the skewed generalization after adaptation to target jump without having been explicitly trained to produce a specific generalization pattern. Our combined psychophysical and simulation results suggest that target jump adaptation in reaching can be explained by gradual updating of spatial motor goal representations in sensorimotor association networks, independent of learning induced by a prediction-error about the hand position. The simulations make testable predictions about the underlying changes in the tuning of sensorimotor neurons during target jump adaptation. PMID:25609106

  4. An investigation into false-negative transthoracic fine needle aspiration and core biopsy specimens.

    PubMed

    Minot, Douglas M; Gilman, Elizabeth A; Aubry, Marie-Christine; Voss, Jesse S; Van Epps, Sarah G; Tuve, Delores J; Sciallis, Andrew P; Henry, Michael R; Salomao, Diva R; Lee, Peter; Carlson, Stephanie K; Clayton, Amy C

    2014-12-01

    Transthoracic fine needle aspiration (TFNA)/core needle biopsy (CNB) under computed tomography (CT) guidance has proved useful in the assessment of pulmonary nodules. We sought to determine the TFNA false-negative (FN) rate at our institution and identify potential causes of FN diagnoses. Medical records were reviewed from 1,043 consecutive patients who underwent CT-guided TFNA with or without CNB of lung nodules over a 5-year time period (2003-2007). Thirty-seven FN cases of "negative" TFNA/CNB with malignant outcome were identified with 36 cases available for review, of which 35 had a corresponding CNB. Cases were reviewed independently (blinded to original diagnosis) by three pathologists with 15 age- and sex-matched positive and negative controls. Diagnosis (i.e., nondiagnostic, negative or positive for malignancy, atypical or suspicious) and qualitative assessments were recorded. Consensus diagnosis was suspicious or positive in 10 (28%) of 36 TFNA cases and suspicious in 1 (3%) of 35 CNB cases, indicating potential interpretive errors. Of the 11 interpretive errors (including both suspicious and positive cases), 8 were adenocarcinomas, 1 squamous cell carcinoma, 1 metastatic renal cell carcinoma, and 1 lymphoma. The remaining 25 FN cases (69.4%) were considered sampling errors and consisted of 7 adenocarcinomas, 3 nonsmall cell carcinomas, 3 lymphomas, 2 squamous cell carcinomas, and 2 renal cell carcinomas. Interpretive and sampling error cases were more likely to abut the pleura, while histopathologically, they tended to be necrotic and air-dried. The overall FN rate in this patient cohort is 3.5% (1.1% interpretive and 2.4% sampling errors). © 2014 Wiley Periodicals, Inc.

  5. The Association of Recreational Space with Youth Smoking in Low Socio-Economic Status Neighborhoods in Santiago, Chile

    PubMed Central

    Grogan-Kaylor, Andrew; Sanhueza, Guillermo; Andrade, Fernando H.; Delva, Jorge

    2013-01-01

    Objectives This study examines the relationship of neighborhood recreational space with youth smoking in mid- to low- income areas in the capital of Chile, Santiago. Methods A unique data set of adolescents (n=779, mean age=14, 51% male) provided home addresses of study participants which were geocoded and mapped. Satellite maps of neighborhoods were used to identify open spaces for recreational use (e.g., soccer fields and plazas). Thiessen polygons were generated to associate study participants with the nearest available open space using ArcGIS. Regression models, with smoking as a dependent variable, were estimated in which age, sex, family socioeconomic status, peer substance usage, neighborhood crime, and accessibility of open space were covariates. Results The results show that residential proximity to recreational space was associated with decreases in tobacco consumption among female adolescents but this association was not statistically significant among male adolescents. Age and neighborhood crime were the common contributing factors for tobacco consumption across both male and female adolescents. Conclusions This study suggests that recreational spaces in proximity to residences may have a positive impact on reducing adolescents’ inclination to consume tobacco. The relationship of the accessibility to such spaces with smoking appears to vary by adolescents’ sex. PMID:23722521

  6. Using Geographic Information Systems for Exposure Assessment in Environmental Epidemiology Studies

    PubMed Central

    Nuckols, John R.; Ward, Mary H.; Jarup, Lars

    2004-01-01

    Geographic information systems (GIS) are being used with increasing frequency in environmental epidemiology studies. Reported applications include locating the study population by geocoding addresses (assigning mapping coordinates), using proximity analysis of contaminant source as a surrogate for exposure, and integrating environmental monitoring data into the analysis of the health outcomes. Although most of these studies have been ecologic in design, some have used GIS in estimating environmental levels of a contaminant at the individual level and to design exposure metrics for use in epidemiologic studies. In this article we discuss fundamentals of three scientific disciplines instrumental to using GIS in exposure assessment for epidemiologic studies: geospatial science, environmental science, and epidemiology. We also explore how a GIS can be used to accomplish several steps in the exposure assessment process. These steps include defining the study population, identifying source and potential routes of exposure, estimating environmental levels of target contaminants, and estimating personal exposures. We present and discuss examples for the first three steps. We discuss potential use of GIS and global positioning systems (GPS) in the last step. On the basis of our findings, we conclude that the use of GIS in exposure assessment for environmental epidemiology studies is not only feasible but can enhance the understanding of the association between contaminants in our environment and disease. PMID:15198921

  7. Associations of Fast Food Restaurant Availability With Dietary Intake and Weight Among African Americans in the Jackson Heart Study, 2000–2004

    PubMed Central

    Diez Roux, Ana V.; Smith, Adam E.; Tucker, Katherine L.; Gore, Larry D.; Zhang, Lei; Wyatt, Sharon B.

    2011-01-01

    Objectives. We examined the associations of fast food restaurant (FFR) availability with dietary intake and weight among African Americans in the southeastern United States. Methods. We investigated cross-sectional associations of FFR availability with dietary intake and body mass index (BMI) and waist circumference in 4740 African American Jackson Heart Study participants (55.2 ±12.6 years, 63.3% women). We estimated FFR availability using circular buffers with differing radii centered at each participant's geocoded residential location. Results. We observed no consistent associations between FFR availability and BMI or waist circumference. Greater FFR availability was associated with higher energy intake among men and women younger than 55 years, even after adjustment for individual socioeconomic status. For each standard deviation increase in 5-mile FFR availability, the energy intake increased by 138 kilocalories (confidence interval [CI] = 70.53, 204.75) for men and 58 kilocalories (CI = 8.55, 105.97) for women. We observed similar associations for the 2-mile FFR availability, especially in men. FFR availability was also unexpectedly positively associated with total fiber intake. Conclusions. FFR availability may contribute to greater energy intake in younger African Americans who are also more likely to consume fast food. PMID:21551382

  8. Trajectories of neighborhood poverty and associations with subclinical atherosclerosis and associated risk factors: the multi-ethnic study of atherosclerosis.

    PubMed

    Murray, Emily T; Diez Roux, Ana V; Carnethon, Mercedes; Lutsey, Pamela L; Ni, Hanyu; O'Meara, Ellen S

    2010-05-15

    The authors used data from the Multi-Ethnic Study of Atherosclerosis and latent trajectory class modeling to determine patterns of neighborhood poverty over 20 years (1980-2000 residential history questionnaires were geocoded and linked to US Census data). Using these patterns, the authors examined 1) whether trajectories of neighborhood poverty were associated with differences in the amount of subclinical atherosclerosis (common carotid intimal-media thickness) and 2) associated risk factors (body mass index, hypertension, diabetes, current smoking) at baseline (January 2000-August 2002). The authors found evidence of 5 stable trajectory groups with differing levels of neighborhood poverty ( approximately 6%, 12%, 20%, 30%, and 45%) and 1 group with 29% poverty in 1980 and approximately 11% in 2000. Mostly for women, higher cumulative neighborhood poverty was generally significantly associated with worse cardiovascular outcomes. Trends generally persisted after adjustment for adulthood socioeconomic position and race/ethnicity, although they were no longer statistically significant. Among women who had moved during the 20 years, the long-term measure had stronger associations with outcomes (except smoking) than a single, contemporaneous measure. Results indicate that cumulative 20-year exposure to neighborhood poverty is associated with greater cardiovascular risk for women. In residentially mobile populations, single-point-in-time measures underestimate long-term effects.

  9. Community Socioeconomic Disadvantage in Midlife Relates to Cortical Morphology via Neuroendocrine and Cardiometabolic Pathways

    PubMed Central

    Gianaros, Peter J.; Kuan, Dora C.-H.; Marsland, Anna L.; Sheu, Lei K.; Hackman, Daniel A.; Miller, Karissa G.; Manuck, Stephen B.

    2017-01-01

    Abstract Residing in communities of socioeconomic disadvantage confers risk for chronic diseases and cognitive aging, as well as risk for biological factors that negatively affect brain morphology. The present study tested whether community disadvantage negatively associates with brain morphology via 2 biological factors encompassing cardiometabolic disease risk and neuroendocrine function. Participants were 448 midlife adults aged 30–54 years (236 women) who underwent structural neuroimaging to assess cortical and subcortical brain tissue morphology. Community disadvantage was indexed by US Census data geocoded to participants' residential addresses. Cardiometabolic risk was indexed by measurements of adiposity, blood pressure, glucose, insulin, and lipids. Neuroendocrine function was indexed from salivary cortisol measurements taken over 3 days, from which we computed the cortisol awakening response, area-under-the-curve, and diurnal cortisol decline. Community disadvantage was associated with reduced cortical tissue volume, cortical surface area, and cortical thickness, but not subcortical morphology. Moreover, increased cardiometabolic risk and a flatter (dysregulated) diurnal cortisol decline mediated the associations of community disadvantage and cortical gray matter volume. These effects were independent of age, sex, and individual-level socioeconomic position. The adverse risks of residing in a disadvantaged community may extend to the cerebral cortex via cardiometabolic and neuroendocrine pathways. PMID:26498832

  10. Air Force Operational Test and Evaluation Center, Volume 2, Number 2

    DTIC Science & Technology

    1988-01-01

    the special class of attributes arc recorded, cost or In place of the normalization ( I). we propose beliefit. the lollowins normalization NUMERICAL ...comprchcnsi\\c set of modular basic data flow to meet requirements at test tools ,. designed to provide flexible data reduction start, then building to...possible. a totlinaion ot the two position error measurement techniques arc used SLR is a methd of fitting a linear model o accumlulate a position error

  11. pyAmpli: an amplicon-based variant filter pipeline for targeted resequencing data.

    PubMed

    Beyens, Matthias; Boeckx, Nele; Van Camp, Guy; Op de Beeck, Ken; Vandeweyer, Geert

    2017-12-14

    Haloplex targeted resequencing is a popular method to analyze both germline and somatic variants in gene panels. However, involved wet-lab procedures may introduce false positives that need to be considered in subsequent data-analysis. No variant filtering rationale addressing amplicon enrichment related systematic errors, in the form of an all-in-one package, exists to our knowledge. We present pyAmpli, a platform independent parallelized Python package that implements an amplicon-based germline and somatic variant filtering strategy for Haloplex data. pyAmpli can filter variants for systematic errors by user pre-defined criteria. We show that pyAmpli significantly increases specificity, without reducing sensitivity, essential for reporting true positive clinical relevant mutations in gene panel data. pyAmpli is an easy-to-use software tool which increases the true positive variant call rate in targeted resequencing data. It specifically reduces errors related to PCR-based enrichment of targeted regions.

  12. Analysis of Video-Based Microscopic Particle Trajectories Using Kalman Filtering

    PubMed Central

    Wu, Pei-Hsun; Agarwal, Ashutosh; Hess, Henry; Khargonekar, Pramod P.; Tseng, Yiider

    2010-01-01

    Abstract The fidelity of the trajectories obtained from video-based particle tracking determines the success of a variety of biophysical techniques, including in situ single cell particle tracking and in vitro motility assays. However, the image acquisition process is complicated by system noise, which causes positioning error in the trajectories derived from image analysis. Here, we explore the possibility of reducing the positioning error by the application of a Kalman filter, a powerful algorithm to estimate the state of a linear dynamic system from noisy measurements. We show that the optimal Kalman filter parameters can be determined in an appropriate experimental setting, and that the Kalman filter can markedly reduce the positioning error while retaining the intrinsic fluctuations of the dynamic process. We believe the Kalman filter can potentially serve as a powerful tool to infer a trajectory of ultra-high fidelity from noisy images, revealing the details of dynamic cellular processes. PMID:20550894

  13. Reducing Formation-Keeping Maneuver Costs for Formation Flying Satellites in Low-Earth Orbit

    NASA Technical Reports Server (NTRS)

    Hamilton, Nicholas

    2001-01-01

    Several techniques are used to synthesize the formation-keeping control law for a three-satellite formation in low-earth orbit. The objective is to minimize maneuver cost and position tracking error. Initial reductions are found for a one-satellite case by tuning the state-weighting matrix within the linear-quadratic-Gaussian framework. Further savings come from adjusting the maneuver interval. Scenarios examined include cases with and without process noise. These results are then applied to a three-satellite formation. For both the one-satellite and three-satellite cases, increasing the maneuver interval yields a decrease in maneuver cost and an increase in position tracking error. A maneuver interval of 8-10 minutes provides a good trade-off between maneuver cost and position tracking error. An analysis of the closed-loop poles with respect to varying maneuver intervals explains the effectiveness of the chosen maneuver interval.

  14. Correction of electrode modelling errors in multi-frequency EIT imaging.

    PubMed

    Jehl, Markus; Holder, David

    2016-06-01

    The differentiation of haemorrhagic from ischaemic stroke using electrical impedance tomography (EIT) requires measurements at multiple frequencies, since the general lack of healthy measurements on the same patient excludes time-difference imaging methods. It has previously been shown that the inaccurate modelling of electrodes constitutes one of the largest sources of image artefacts in non-linear multi-frequency EIT applications. To address this issue, we augmented the conductivity Jacobian matrix with a Jacobian matrix with respect to electrode movement. Using this new algorithm, simulated ischaemic and haemorrhagic strokes in a realistic head model were reconstructed for varying degrees of electrode position errors. The simultaneous recovery of conductivity spectra and electrode positions removed most artefacts caused by inaccurately modelled electrodes. Reconstructions were stable for electrode position errors of up to 1.5 mm standard deviation along both surface dimensions. We conclude that this method can be used for electrode model correction in multi-frequency EIT.

  15. High-speed photogrammetry system for measuring the kinematics of insect wings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, Iain D.; Lawson, Nicholas J.; Harvey, Andrew R.

    2006-06-10

    We describe and characterize an experimental system to perform shape measurements on deformable objects using high-speed close-range photogrammetry. The eventual application is to extract the kinematics of several marked points on an insect wing during tethered and hovering flight. We investigate the performance of the system with a small number of views and determine an empirical relation between the mean pixel error of the optimization routine and the position error. Velocity and acceleration are calculated by numerical differencing, and their relation to the position errors is verified. For a field of view of {approx}40mmx40 mm, a rms accuracy of 30more » {mu}m in position, 150 mm/s in velocity, and 750 m/s2 in acceleration at 5000 frames/s is achieved. This accuracy is sufficient to measure the kinematics of hoverfly flight.« less

  16. The Effect of Antenna Position Errors on Redundant-Baseline Calibration of HERA

    NASA Astrophysics Data System (ADS)

    Orosz, Naomi; Dillon, Joshua; Ewall-Wice, Aaron; Parsons, Aaron; HERA Collaboration

    2018-01-01

    HERA (the Hydrogen Epoch of Reionization Array) is a large, highly-redundant radio interferometer in South Africa currently being built out to 350 14-m dishes. Its mission is to probe large scale structure during and prior to the epoch of reionization using the 21 cm hyperfine transition of neutral hydrogen. The array is designed to be calibrated using redundant baselines of known lengths. However, the dishes can deviate from ideal positions, with errors on the order of a few centimeters. This potentially increases foreground contamination of the 21 cm power spectrum in the cleanest part of Fourier space. The calibration algorithm treats groups of baselines that should be redundant, but are not due to position errors, as if they actually are. Accurate, precise calibration is critical because the foreground signals are 100,000 times stronger than the reionization signal. We explain the origin of this effect and discuss weighting strategies to mitigate it.

  17. VizieR Online Data Catalog: PMA Catalogue (Akhmetov+, 2017)

    NASA Astrophysics Data System (ADS)

    Akhmetov, V. S.; Fedorov, P. N.; Velichko, A. B.; Shulga, V. M.

    2017-06-01

    The idea for creating the catalogue is very simple. The PMA catalogue has been derived from a combination of two catalogues, namely 2MASS and Gaia DR1. The difference of epochs of observations for these catalogues is approximately 15 yr. The positions of objects in the Gaia DR1 catalogue are referred to the reference frame, which is consistent with ICRF to better than 0.1 mas for the J2015.0 epoch. The positions of objects in 2MASS are referred to HCRF, which, as was shown in Kovalevsky et al. (1997A&A...323..620K), is aligned with the ICRF to within ±0.6 mas at the epoch 1991.25 and is non-rotating with respect to distant extragalactic objects to within ±0.25mas/yr. By comparing the positions of the common objects contained in the catalogues, it is possible to determine their proper motions within their common range of stellar magnitudes by dividing differences of positions over the time interval between their observations. Formally, proper motions derived in such a way are given in the ICRF system, because the positions of both Gaia DR1 stars and those of 2MASS objects (through Hipparcos/Tycho-2 stars) are given in the ICRF and cover the whole sphere without gaps. We designate them further in this paper as relative, with the aim of discriminating them from absolute ones, which refer to the reference frame defined by the positions of about 1.6 million galaxies from Gaia DR1. There is no possibility of obtaining estimates of individual errors of proper motions of stars for the PMA Catalogue from the intrinsic convergence, because the direct errors for positions are not indicated in 2MASS. Therefore we use some indirect methods to obtain the estimates of uncertainties for proper motions. After elimination of the systematic errors, the root-mean-squared deviation of the coordinate differences of extended sources is about 200mas, and the mean number of galaxies inside each pixel is about 1300, so we expect the error of the absolute calibration to be 0.35mas/yr. We compared the proper motions of common objects from PMA and from the TGAS and UCAC4 catalogues. Knowing the mean-square errors of (PMA-TGAS) and (PMA-UCAC4) proper motion differences in each pixel, the appropriate errors in PMA vary from 2 to 10mas/yr, depending on magnitude, which are consistent with the errors calculated above. In case of any problems or questions, please contact by e-mail V.S. Akhmetov (akhmetovvs(at)gmail.com or akhmetov(at)astron.kharkov.ua). (1 data file).

  18. The Effects of Lever Arm (Instrument Offset) Error on GRAV-D Airborne Gravity Data

    NASA Astrophysics Data System (ADS)

    Johnson, J. A.; Youngman, M.; Damiani, T.

    2017-12-01

    High quality airborne gravity collection with a 2-axis, stabilized platform gravity instrument, such as with a Micro-g LaCoste Turnkey Airborne Gravity System (TAGS), is dependent on the aircraft's ability to maintain "straight and level" flight. However, during flight there is constant rotation about the aircraft's center of gravity. Standard practice is to install the scientific equipment close to the aircraft's estimated center of gravity to minimize the relative rotations with aircraft motion. However, there remain small offsets between the instruments. These distance offsets, the lever arm, are used to define the rigid-body, spatial relationship between the IMU, GPS antenna, and airborne gravimeter within the aircraft body frame. The Gravity for the Redefinition of the American Vertical Datum (GRAV-D) project, which is collecting airborne gravity data across the U.S., uses a commercial software package for coupled IMU-GNSS aircraft positioning. This software incorporates a lever arm correction to calculate a precise position for the airborne gravimeter. The positioning software must do a coordinate transformation to relate each epoch of the coupled GNSS-IMU derived position to the position of the gravimeter within the constantly-rotating aircraft. This transformation requires three inputs: accurate IMU-measured aircraft rotations, GNSS positions, and lever arm distances between instruments. Previous studies show that correcting for the lever arm distances improves gravity results, but no sensitivity tests have been done to investigate how error in the lever arm distances affects the final airborne gravity products. This research investigates the effects of lever arm measurement error on airborne gravity data. GRAV-D lever arms are nominally measured to the cm-level using surveying equipment. "Truth" data sets will be created by processing GRAV-D flight lines with both relatively small lever arms and large lever arms. Then negative and positive incremental errors will be introduced independently in the x, y, and z directions during GPS-IMU processing. Finally, the post-processed gravity data obtained using the erroneous lever arms will be compared to the post-processed truth sets to identify relationships between error in the lever arm measurement and the final gravity product.

  19. Evaluation of Natural Language Processing (NLP) Systems to Annotate Drug Product Labeling with MedDRA Terminology.

    PubMed

    Ly, Thomas; Pamer, Carol; Dang, Oanh; Brajovic, Sonja; Haider, Shahrukh; Botsis, Taxiarchis; Milward, David; Winter, Andrew; Lu, Susan; Ball, Robert

    2018-05-31

    The FDA Adverse Event Reporting System (FAERS) is a primary data source for identifying unlabeled adverse events (AEs) in a drug or biologic drug product's postmarketing phase. Many AE reports must be reviewed by drug safety experts to identify unlabeled AEs, even if the reported AEs are previously identified, labeled AEs. Integrating the labeling status of drug product AEs into FAERS could increase report triage and review efficiency. Medical Dictionary for Regulatory Activities (MedDRA) is the standard for coding AE terms in FAERS cases. However, drug manufacturers are not required to use MedDRA to describe AEs in product labels. We hypothesized that natural language processing (NLP) tools could assist in automating the extraction and MedDRA mapping of AE terms in drug product labels. We evaluated the performance of three NLP systems, (ETHER, I2E, MetaMap) for their ability to extract AE terms from drug labels and translate the terms to MedDRA Preferred Terms (PTs). Pharmacovigilance-based annotation guidelines for extracting AE terms from drug labels were developed for this study. We compared each system's output to MedDRA PT AE lists, manually mapped by FDA pharmacovigilance experts using the guidelines, for ten drug product labels known as the "gold standard AE list" (GSL) dataset. Strict time and configuration conditions were imposed in order to test each system's capabilities under conditions of no human intervention and minimal system configuration. Each NLP system's output was evaluated for precision, recall and F measure in comparison to the GSL. A qualitative error analysis (QEA) was conducted to categorize a random sample of each NLP system's false positive and false negative errors. A total of 417, 278, and 250 false positive errors occurred in the ETHER, I2E, and MetaMap outputs, respectively. A total of 100, 80, and 187 false negative errors occurred in ETHER, I2E, and MetaMap outputs, respectively. Precision ranged from 64% to 77%, recall from 64% to 83% and F measure from 67% to 79%. I2E had the highest precision (77%), recall (83%) and F measure (79%). ETHER had the lowest precision (64%). MetaMap had the lowest recall (64%). The QEA found that the most prevalent false positive errors were context errors such as "Context error/General term", "Context error/Instructions or monitoring parameters", "Context error/Medical history preexisting condition underlying condition risk factor or contraindication", and "Context error/AE manifestations or secondary complication". The most prevalent false negative errors were in the "Incomplete or missed extraction" error category. Missing AE terms were typically due to long terms, or terms containing non-contiguous words which do not correspond exactly to MedDRA synonyms. MedDRA mapping errors were a minority of errors for ETHER and I2E but were the most prevalent false positive errors for MetaMap. The results demonstrate that it may be feasible to use NLP tools to extract and map AE terms to MedDRA PTs. However, the NLP tools we tested would need to be modified or reconfigured to lower the error rates to support their use in a regulatory setting. Tools specific for extracting AE terms from drug labels and mapping the terms to MedDRA PTs may need to be developed to support pharmacovigilance. Conducting research using additional NLP systems on a larger, diverse GSL would also be informative. Copyright © 2018. Published by Elsevier Inc.

  20. Triangulation Error Analysis for the Barium Ion Cloud Experiment. M.S. Thesis - North Carolina State Univ.

    NASA Technical Reports Server (NTRS)

    Long, S. A. T.

    1973-01-01

    The triangulation method developed specifically for the Barium Ion Cloud Project is discussed. Expression for the four displacement errors, the three slope errors, and the curvature error in the triangulation solution due to a probable error in the lines-of-sight from the observation stations to points on the cloud are derived. The triangulation method is then used to determine the effect of the following on these different errors in the solution: the number and location of the stations, the observation duration, east-west cloud drift, the number of input data points, and the addition of extra cameras to one of the stations. The pointing displacement errors, and the pointing slope errors are compared. The displacement errors in the solution due to a probable error in the position of a moving station plus the weighting factors for the data from the moving station are also determined.

Top