Sample records for glare

  1. Solar glare hazard analysis tool on account of determined points of time

    DOEpatents

    Ho, Clifford K; Sims, Cianan Alexander

    2014-09-23

    Technologies pertaining to determining when glare will be perceived by a hypothetical observer from a glare source and the intensity of glare that will be perceived by the hypothetical observer from the glare source are described herein. A first location of a potential source of solar glare is received, and a second location of the hypothetical observer is received. Based upon such locations, including respective elevations, and known positions of the sun over time, a determination as to when the hypothetical observer will perceive glare from the potential source of solar glare is made. Subsequently, an amount of irradiance entering the eye of the hypothetical observer is calculated to assess potential ocular hazards.

  2. Lasers' spectral and temporal profile can affect visual glare disability.

    PubMed

    Beer, Jeremy M A; Freeman, David A

    2012-12-01

    Experiments measured the effects of laser glare on visual orientation and motion perception. Laser stimuli were varied according to spectral composition and temporal presentation as subjects identified targets' tilt (Experiment 1) and movement (Experiment 2). The objective was to determine whether the glare parameters would alter visual disruption. Three spectral profiles (monochromatic Green vs. polychromatic White vs. alternating Red-Green) were used to produce a ring of laser glare surrounding a target. Two experiments were performed to measure the minimum contrast required to report target orientation or motion direction. The temporal glare profile was also varied: the ring was illuminated either continuously or discontinuously. Time-averaged luminance of the glare stimuli was matched across all conditions. In both experiments, threshold (deltaL) values were approximately 0.15 log units higher in monochromatic Green than in polychromatic White conditions. In Experiment 2 (motion identification), thresholds were approximately 0.17 log units higher in rapidly flashing (6, 10, or 14 Hz) than in continuous exposure conditions. Monochromatic extended-source laser glare disrupted orientation and motion identification more than polychromatic glare. In the motion task, pulse trains faster than 6 Hz (but below flicker fusion) elevated thresholds more than continuous glare with the same time-averaged luminance. Under these conditions, alternating the wavelength of monochromatic glare over time did not aggravate disability relative to green-only glare. Repetitively flashing monochromatic laser glare induced occasional episodes of impaired motion identification, perhaps resulting from cognitive interference. Interference speckle might play a role in aggravating monochromatic glare effects.

  3. 76 FR 35415 - Procurement List; Proposed Additions and Deletions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-17

    ... Shields NSN: 7045-00-NIB-0326--Glare Shield for iPhone. NSN: 7045-00-NIB-0327--Glare Shield for Blackberry Bold. NSN: 7045-00-NIB-0328--Glare Shield for Blackberry Storm2. NSN: 7045-00-NIB-0366--Glare Shield for Blackberry Curve2. NSN: 7045-00-NIB-0329--Universal PDA Glare Shield. NSN: 7045-00-NIB-0330...

  4. Anti-Glare Filters

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Glare from CRT screens has been blamed for blurred vision, eyestrain, headaches, etc. Optical Coating Laboratory, Inc. (OCLI) manufactures a coating to reduce glare which was used to coat the windows on the Gemini and Apollo spacecraft. In addition, OCLI offers anti-glare filters (Glare Guard) utilizing the same thin film coating technology. The coating minimizes brightness, provides enhanced contrast and improves readability. The filters are OCLI's first consumer product.

  5. Macular pigment and visual performance in glare: benefits for photostress recovery, disability glare, and visual discomfort.

    PubMed

    Stringham, James M; Garcia, Paul V; Smith, Peter A; McLin, Leon N; Foutch, Brian K

    2011-09-22

    One theory of macular pigment's (MP) presence in the fovea is to improve visual performance in glare. This study sought to determine the effect of MP level on three aspects of visual performance in glare: photostress recovery, disability glare, and visual discomfort. Twenty-six subjects participated in the study. Spatial profiles of MP optical density were assessed with heterochromatic flicker photometry. Glare was delivered via high-bright-white LEDs. For the disability glare and photostress recovery portions of the experiment, the visual task consisted of correct identification of a 1° Gabor patch's orientation. Visual discomfort during the glare presentation was assessed with a visual discomfort rating scale. Pupil diameter was monitored with an infrared (IR) camera. MP level correlated significantly with all the outcome measures. Higher MP optical densities (MPODs) resulted in faster photostress recovery times (average P < 0.003), lower disability glare contrast thresholds (average P < 0.004), and lower visual discomfort (P = 0.002). Smaller pupil diameter during glare presentation significantly correlated with higher visual discomfort ratings (P = 0.037). MP correlates with three aspects of visual performance in glare. Unlike previous studies of MP and glare, the present study used free-viewing conditions, in which effects of iris pigmentation and pupil size could be accounted for. The effects described, therefore, can be extended more confidently to real-world, practical visual performance benefits. Greater iris constriction resulted (paradoxically) in greater visual discomfort. This finding may be attributable to the neurobiologic mechanism that mediates the pain elicited by light.

  6. Image degradation by glare in radiologic display devices

    NASA Astrophysics Data System (ADS)

    Badano, Aldo; Flynn, Michael J.

    1997-05-01

    No electronic devices are currently available that can display digital radiographs without loss of visual information compared to traditional transilluminated film. Light scattering within the glass faceplate of cathode-ray tube (CRT) devices causes excessive glare that reduces image contrast. This glare, along with ambient light reflection, has been recognized as a significant limitation for radiologic applications. Efforts to control the effect of glare and ambient light reflection in CRTs include the use of absorptive glass and thin film coatings. In the near future, flat panel displays (FPD) with thin emissive structures should provide very low glare, high performance devices. We have used an optical Monte Carlo simulation to evaluate the effect of glare on image quality for typical CRT and flat panel display devices. The trade-off between display brightness and image contrast is described. For CRT systems, achieving good glare ratio requires a reduction of brightness to 30-40 percent of the maximum potential brightness. For FPD systems, similar glare performance can be achieved while maintaining 80 percent of the maximum potential brightness.

  7. Could Daylight Glare Be Defined Mathematically?Results of Testing the DGIN Method in Japan

    NASA Astrophysics Data System (ADS)

    Nazzal, Ali; Oki, Masato

    Discomfort glare from daylight is a common problem without valid prediction methods so far. A new mathematical DGIN (New Daylight Glare Index) method tries to respond the challenge. This paper reports on experiments carried out in daylit office environment in Japan to test applicability of the method. Slight positive correlation was found between the DGIN and the subjective evaluation. Additionally, a high Ladaptation value together with the small ratio of Lwindow to Ladaptation was obviously experienced sufficient to neutralize the effect of glare discomfort. However, subjective assessments are poor glare indicators and not reliable in testing glare prediction methods. DGIN is a good indicator of daylight glare, and when the DGIN value is analyzed together with the measured illuminance ratios, discomfort glare from daylight can be analyzed in a quantitative manner. The DGIN method could serve architects and lighting designers in testing daylighting systems, and also guide the action of daylight responsive lighting controls.

  8. Dazzling Glare: Protection Criteria Versus Visual Performance

    DTIC Science & Technology

    1989-06-07

    6 3 Coherent vs Noncoherent Intraocular Glare ................................................................ 7 4 Coherent vs... Noncoherent Interocular Glare ................................................ 8.............. 5 Filtered Xenon Are Lamp vs Helium Neon Laser...glare effects in order to design more effective protective eyewear and to ensure that those who might be exposed in an operational setting know what

  9. Effect of glare on simple reaction time.

    PubMed

    Aguirre, Rolando C; Colombo, Elisa M; Barraza, José F

    2008-07-01

    We systematized the study of the effect of glare on reaction time (RT), for visual conditions similar to the ones found during night driving: Mesopic range of adaptation (0.14 cd/m2), glare levels of the order of those produced by car headlights (E(G)=15, 60 lx), suprathreshold luminance contrasts, and a variety of spatial frequencies covering the selected range of visibility (1, 2, 4, and 8 c/deg). We found that for the no-glare situation, RT increases with decreasing contrast and increasing spatial frequency, which agrees with previous findings. When data are plotted as a function of the inverse of contrast, RT varies linearly, with k--the RT-contrast factor of Pieron's law--representing the slope of the lines. The effect of glare on RT is an increase in the slope of these lines. This effect is different for each spatial frequency, which cannot be accounted for in the classic approach considering that glare can be replaced by a single veiling luminance. We show that the effect of glare on RT must be modeled by an equivalent glare luminance that depends on spatial frequency.

  10. Evaluation of glare at the Ivanpah Solar Electric Generating System

    DOE PAGES

    Ho, C. K.; Sims, C. A.; Christian, J. M.

    2015-06-05

    The Ivanpah Solar Electric Generating System (ISEGS), located on I-15 about 40 miles (60 km) south of Las Vegas, NV, consists of three power towers 459 ft (140 m) tall and over 170,000 reflective heliostats with a rated capacity of 390 MW. In addition, reports of glare from the plant have been submitted by pilots and air traffic controllers and recorded by the Aviation Safety Reporting System and the California Energy Commission since 2013. Aerial and ground-based surveys of the glare were conducted in April, 2014, to identify the cause and to quantify the irradiance and potential ocular impacts ofmore » the glare. Results showed that the intense glare viewed from the airspace above ISEGS was caused by heliostats in standby mode that were aimed to the side of the receiver. Evaluation of the glare showed that the retinal irradiance and subtended source angle of the glare from the heliostats in standby were sufficient to cause significant ocular impact (potential for after-image) up to a distance of ~6 miles (10 km), but the values were below the threshold for permanent eye damage. Glare from the receivers had a low potential for after-image at all ground-based monitoring locations outside of the site boundaries. A Letter to Airmen has been issued by the Federal Aviation Administration to notify pilots of the potential glare hazards. Additional measures to mitigate the potential impacts of glare from ISGES are also presented and discussed.« less

  11. Loading-unloading response of circular GLARE fiber-metal laminates under lateral indentation

    NASA Astrophysics Data System (ADS)

    Tsamasphyros, George J.; Bikakis, George S.

    2015-01-01

    GLARE is a Fiber-Metal laminated material used in aerospace structures which are frequently subjected to various impact damages. Hence, the response of GLARE plates subjected to lateral indentation is very important. In this paper, analytical expressions are derived and a non-linear finite element modeling procedure is proposed in order to predict the static load-indentation curves of circular GLARE plates during loading and unloading by a hemispherical indentor. We have recently published analytical formulas and a finite element procedure for the static indentation of circular GLARE plates which are now used during the loading stage. Here, considering that aluminum layers are in a state of membrane yield and employing energy balance during unloading, the unloading path is determined. Using this unloading path, an algebraic equation is derived for calculating the permanent dent depth of the GLARE plate after the indentor's withdrawal. Furthermore, our finite element procedure is modified in order to simulate the unloading stage as well. The derived formulas and the proposed finite element modeling procedure are applied successfully to GLARE 2-2/1-0.3 and to GLARE 3-3/2-0.4 circular plates. The analytical results are compared with corresponding FEM results and a good agreement is found. The analytically calculated permanent dent depth is within 6 % for the GLARE 2 plate, and within 7 % for the GLARE 3 plate, of the corresponding numerically calculated result. No other solution of this problem is known to the authors.

  12. Using the Freiburg Acuity and Contrast Test to measure visual performance in USAF personnel after PRK.

    PubMed

    Dennis, Richard J; Beer, Jeremy M A; Baldwin, J Bruce; Ivan, Douglas J; Lorusso, Frank J; Thompson, William T

    2004-07-01

    Photorefractive keratectomy (PRK) may be an alternative to spectacle and contact lens wear for United States Air Force (USAF) aircrew and may offer some distinct advantages in operational situations. However, any residual corneal haze or scar formation from PRK could exacerbate the disabling effects of a bright glare source on a complex visual task. The USAF recently completed a longitudinal clinical evaluation of the long-term effects of PRK on visual performance, including the experiment described herein. After baseline data were collected, 20 nonflying active duty USAF personnel underwent PRK. Visual performance was then measured at 6, 12, and 24 months after PRK. Visual acuity (VA) and contrast sensitivity (CS) data were collected by using the Freiburg Acuity and Contrast Test (FrACT), with the subject viewing half of the runs through a polycarbonate windscreen. Experimental runs were completed under 3 glare conditions: no glare source and with either a broadband or a green laser (532-nm) glare annulus (luminance approximately 6090 cd/m) surrounding the Landolt C stimulus. Systematic effects of PRK on VA relative to baseline were not identified. However, VA was almost 2 full Snellen lines worse with the laser glare source in place versus the broadband glare source. A significant drop-off was observed in CS performance after PRK under conditions of no glare and broadband glare; this was the case both with and without the windscreen. As with VA, laser glare disrupted CS performance significantly and more than broadband glare did. PRK does not appear to have affected VA, but the changes in CS might represent a true decline in visual performance. The greater disruptive effects from laser versus broadband glare may be a result of increased masking from coherent spatial noise (speckle) surrounding the laser stimulus.

  13. Evaluation of Glare at the Ivanpah Solar Electric Generating System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Clifford K.; Sims, Cianan; Christian, Joshua Mark

    2014-07-01

    The Ivanpah Solar Electric Generating System (ISEGS), located on I - 15 about 40 miles (60 km) south of Las Vegas, NV, consists of three power towers 459 ft (140 m) tall and over 170,000 reflective heliostats with a rated capacity of 390 MW. Reports of glare from the plant have been submitted by pilots and air traffic controllers and recorded by the Aviation Safety Reporting System and the California Energy Commission since 2013. Aerial and ground - based surveys of the glare were conducted in April, 2014, to identify the cause and to quantify the irradiance and potential ocularmore » impact s of the glare . Results showed that the intense glare viewed from the airspace above ISEGS was caused by he liostats in standby mode that were aimed to the side of the receiver. Evaluation of the glare showed that the retinal irradiance and subtended source angle of the glare from the heliostats in standby were sufficient to cause significant ocular impact (pot ential for after - image) up to a distance of %7E6 miles (10 km), but the values were below the threshold for permanent eye damage . Glare from the receivers had a low potential for after - image at all ground - based monitoring locations outside of the site bound aries. A Letter to Airmen has been issued by the Federal Aviation Administration to notify pilots of the potential glare hazards. Additional measures to mitigate the potential impacts of glare from ISGES are also presented and discussed. This page intentionally left blank« less

  14. The effect of building facade reflectivity on urban dwellers in tropics.

    NASA Astrophysics Data System (ADS)

    Ishak, N. M.; Hien, W. N.; Jenatabadi, H. S.; Ignatius, M.; Yaman, R.

    2018-02-01

    With the rapid growth and use of modern architecture practices for high-rise buildings, highly reflective materials have been adopted extensively for aesthetical reasons. However, outdoor glare from highly reflective facades might cause thermal and visual problems towards the occupants of neighbouring buildings and outdoor dwellers, particularly pedestrians. In tropical countries, this negative impact can be greater due to the higher solar radiation received throughout the year. At the present, there are few building guidelines limiting outdoor glare, or daylight reflectance from a building facade. This study aims to introduce a framework for outdoor glare studies that focus on perceived glare from highly reflective facades by pedestrians in Singapore. The introduced framework includes age, glare time, glare duration, avoidance and sensitiveness. For this study, the survey is carried out with the application of Structural Equation Modelling (SEM). This paper is helpful for planners, designers, and engineers to estimate the sensitivity of pedestrians’ discomfort glare and towards the creation of sustainable architecture in Singapore.

  15. Survey of discomfort glare from the headlamps of cars widely used in Iran.

    PubMed

    Mehri, Ahmad; Farhang Dehghan, Somayeh; Hajizadeh, Roohalah; Zakerian, Seyed Abolfazl; Mohammadi, Hamzeh; Abbasi, Milad

    2017-10-03

    On 2-lane roads, discomfort glare can cause annoyance, discomfort, inconvenience, stress, and fatigue to drivers, posing a risk of accidents. The aim of this study is to evaluate discomfort glare from the headlamps of cars widely used in Iran. The discomfort glare of new vehicles including Pride Saba model GTX, Pride Model 131SL, Samand Soren, Peugeot 405, Megane, and Peugeot Pars was examined at distances of 5 to 100 m at a background luminance of 50 cd/m 2 (late twilight/early dawn lighting) and 1 cd/m 2 (nighttime) using Schmidt-Clausen and Bindels model and de Boer's subjective scale. According to the de Boer scale, at a background luminance of 50 cd/m 2 , the discomfort glare for all studied vehicles was between 1.98 and 4.05 in high-beam mode and between 3.5 and 5.4 in low-beam mode. At a background luminance of 1 cd/m 2 , discomfort glare was between 0.41 and 2.48 in high-beam mode and between 1.93 and 3.84 in low-beam mode. In high-beam mode, the average levels of discomfort glare of these vehicles gradually increased when the distance between cars was reduced by up to about 20 m. In low-beam mode, there was no discomfort glare up to a vehicle distance of 40 m. In addition, at an angle of 1.15°-5.73° between the line of sight and light of vehicles in high-beam mode, the level of discomfort glare was increased, but at an angle of 5.73°-22.9° the level of discomfort glare was reduced. In low-beam mode at an angle of 2.86°-22.9°, the level of discomfort glare was almost identical. The results show that in high-beam mode and with a 100-m distance between vehicles as well as in low-beam mode at intervals of less than 40 m between cars, discomfort glare is created. It can be concluded that by providing solutions such as installing road lighting system, an increase in luminance of roads, separating or widening road lanes, increasing the lateral distance between vehicles, and increasing the angle between lighted vehicles and drivers can noticeably reduce discomfort glare.

  16. Macular pigment spatial distribution effects on glare disability.

    PubMed

    Putnam, Christopher M; Bassi, Carl J

    2015-01-01

    This project explored the relationship of the macular pigment optical density (MPOD) spatial profile with measures of glare disability (GD) across the macula. A novel device was used to measure MPOD across the central 16° of retina along four radii using customized heterochromatic flicker photometry (cHFP)at eccentricities of 0°, 2°, 4°, 6° and 8°. MPOD was measured as discrete and integrated values at all measured retinal loci. GD was calculated as a difference in contrast sensitivity (CS) between no glare and glare conditions using identical stimuli presented at the same eccentricities. GD was defined as [(CSNo Glare-CSGlare)/CSNo Glare] in order to isolate the glare attenuation effects of MPOD by controlling for CS variability among the subject sample. Correlations of the discrete and integrated MPOD with GD were compared. The cHFP identified reliable MPOD spatial distribution maps demonstrating a 1st-order exponential decay as a function of increasing eccentricity. There was a significant negative correlation between both measures of foveal MPOD and GD using 6 cycles per degree (cpd) and 9 cpd stimuli. Significant correlations were found between corresponding parafoveal MPOD measures and GD at 2 and 4° of eccentricity using 9 cpd stimuli with greater MPOD associated with less glare disability. These results are consistent with the glare attenuation effects of MP at higher spatial frequencies and support the hypothesis that discrete and integrated measures of MPOD have similar correlations with glare attenuation effects across the macula. Additionally, peak foveal MPOD appears to influence GD across the macula. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  17. Veiling glare reduction methods compared for ophthalmic applications

    NASA Technical Reports Server (NTRS)

    Buchele, D. R.

    1981-01-01

    Veiling glare in ocular viewing was simulated by viewing the retina of an eye model through a sheet of light-scattering material lit from the front. Four methods of glare reduction were compared, namely, optical scanning, polarized light, viewing and illumination paths either coaxial or intersecting at the object, and closed circuit TV. Photographs show the effect of these methods on visibility. Polarized light was required to eliminate light specularly reflected from the instrument optics. The greatest glare reduction was obtained when the first three methods were utilized together. Glare reduction using TV was limited by nonuniform distribution of scattered light over the image.

  18. Psychophysical investigations of discomfort and disability glare from underground coal mine illumination systems. Open File Report, May 1980-July 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitehead, K.L.; Lindahl, P.; Vincent, R.

    1983-10-01

    A literature search was conducted to identify current light-control technology and hardware that may be applicable on underground lighting systems to minimize disability and discomfort glare. No research dealing specifically with mine lighting was found, but abstracts on research considered potentially applicable are included in the report. Information on several commercial light-control products for use in controlling glare are also included. Vision tests conducted on 137 mine personnel to determine their discomfort and disability glare sensitivity indicate their sensitivity to disability glare is about the same as the general population.

  19. An experimental investigation of glare and restructured fiber metal laminates

    NASA Astrophysics Data System (ADS)

    Benedict, Adelina Vanessa

    Fiber Metal Laminates (FMLs) are a group of materials fabricated by bonding glass/epoxy layers within metal layers. This class of materials can provide good mechanical properties, as well as weight savings. An FML known as Glass Laminate Aluminum Reinforced Epoxy (GLARE) was studied. An experimental investigation comprising of microscopy and tensile testing was carried out using different grades of GLARE. Microscopy revealed the construction details of GLARE, while tensile testing provided means of measuring and analyzing its stress-strain responses. Next, different metal surface pretreatment methods were explored. These included sandblasting, Phosphoric Acid Anodizing (PAA), and AC-130 Sol-Gel treatment. Woven S-2 glass, an epoxy adhesive, and aluminum alloy sheet metal were used to fabricate restructured FMLs using time and cost effective procedures. Additional microscopy and tensile testing allowed for comparisons with GLARE and aircraft grade aluminum alloys. The restructured FMLs showed similar behaviors to GLARE with potential significant improvements in fabrication efficiency.

  20. Influence of the Metal Volume Fraction on the maximum deflection and impact load of GLARE plates subjected to low velocity impact

    NASA Astrophysics Data System (ADS)

    Bikakis, GSE; Savaidis, A.; Zalimidis, P.; Tsitos, S.

    2016-11-01

    Fiber-metal laminates are hybrid composite materials, consisting of alternating metal layers bonded to fiber-reinforced prepreg layers. GLARE (GLAss REinforced) belongs to this new family of materials. GLARE is the most successful fiber-metal laminate up to now and is currently being used for the construction of primary aerospace structures, such as the fuselage of the Airbus A380 air plane. Impact properties are very important in aerospace structures, since impact damage is caused by various sources, such as maintenance damage from dropped tools, collision between service cars or cargo and the structure, bird strikes and hail. The principal objective of this article is to evaluate the influence of the Metal Volume Fraction (MVF) on the low velocity impact response of GLARE fiber-metal laminates. Previously published differential equations of motion are employed for this purpose. The low velocity impact behavior of various circular GLARE plates is predicted and characteristic values of impact variables, which represent the impact phenomenon, are evaluated versus the corresponding MVF of the examined GLARE material grades. The considered GLARE plates are subjected to low velocity impact under identical impact conditions. A strong effect of the MVF on the maximum impact load and a significant effect on the maximum plate deflection of GLARE plates has been found.

  1. Influence of the Metal Volume Fraction on the permanent dent depth and energy absorption of GLARE plates subjected to low velocity impact

    NASA Astrophysics Data System (ADS)

    Bikakis, GSE; Savaidis, A.; Zalimidis, P.; Tsitos, S.

    2016-11-01

    Fiber-metal laminates are hybrid composite materials, consisting of alternating metal layers bonded to fiber-reinforced prepreg layers. GLARE (GLAss REinforced) belongs to this new family of materials. GLARE is the most successful fiber-metal laminate up to now and is currently being used for the construction of primary aerospace structures, such as the fuselage of the Airbus A380 air plane. Impact properties are very important in aerospace structures, since impact damage is caused by various sources, such as maintenance damage from dropped tools, collision between service cars or cargo and the structure, bird strikes and hail. The principal objective of this article is to evaluate the influence of the Metal Volume Fraction (MVF) on the low velocity impact response of GLARE fiber-metal laminates. Previously published differential equations of motion are employed for this purpose. The low velocity impact behavior of various circular GLARE plates is predicted and characteristic values of impact variables, which represent the impact phenomenon, are evaluated versus the corresponding MVF of the examined GLARE material grades. The considered GLARE plates are subjected to low velocity impact under identical impact conditions. A strong effect of the MVF on the maximum impact load and a significant effect on the maximum plate deflection of GLARE plates has been found.

  2. A portable inspection system to estimate direct glare of various LED modules

    NASA Astrophysics Data System (ADS)

    Chen, Po-Li; Liao, Chun-Hsiang; Li, Hung-Chung; Jou, Shyh-Jye; Chen, Han-Ting; Lin, Yu-Hsin; Tang, Yu-Hsiang; Peng, Wei-Jei; Kuo, Hui-Jean; Sun, Pei-Li; Lee, Tsung-Xian

    2015-07-01

    Glare is caused by both direct and indirect light sources and discomfort glare produces visual discomfort, annoyance, or loss in visual performance and visibility. Direct glare is caused by light sources in the field of view whereas reflected glare is caused by bright reflections from polished or glossy surfaces that are reflected toward an individual. To improve visual comfort of our living environment, a portable inspection system to estimate direct glare of various commercial LED modules with the range of color temperature from 3100 K to 5300 K was developed in this study. The system utilized HDR images to obtain the illumination distribution of LED modules and was first calibrated for brightness and chromaticity and corrected with flat field, dark-corner and curvature by the installed algorithm. The index of direct glare was then automatically estimated after image capturing, and the operator can recognize the performance of LED modules and the possible effects on human being once the index was out of expecting range. In the future, we expect that the quick-response smart inspection system can be applied in several new fields and market, such as home energy diagnostics, environmental lighting and UGR monitoring and popularize it in several new fields.

  3. The applicability of commercial glare test devices in the aeromedical certification of pilot applicants.

    DOT National Transportation Integrated Search

    1994-08-01

    In his FY 92/93 Annual Program Guidance and Current Policy Statement, the Federal Air Surgeon requested continued investigation of new testing modalities, such as glare vision testing, as to their relevance to medical certification. Glare sensitivity...

  4. The dark side of photovoltaic — 3D simulation of glare assessing risk and discomfort

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rose, Thomas; Wollert, Alexander

    2015-04-15

    Photovoltaic (PV) systems form an important force in the implementation of renewable energies, but as we all know, the force has always its dark side. Besides efficiency considerations and discussions about architectures of power distribution networks, the increasing numbers of installations of PV systems for implementing renewable energies have secondary effects. PV systems can generate glare due to optical reflections and hence might be a serious concern. On the one hand, glare could affect safety, e.g. regarding traffic. On the other hand, glare is a constant source of discomfort in vicinities of PV systems. Hence, assessment of glare is decisivemore » for the success of renewable energies near municipalities and traffic zones for the success of solar power. Several courts decided on the change of PV systems and even on their de-installation because of glare effects. Thus, location-based assessments are required to limit potential reflections and to avoid risks for public infrastructure or discomfort of residents. The question arises on how to calculate reflections accurately according to the environment's topography. Our approach is founded in a 3D-based simulation methodology to calculate and visualize reflections based on the geometry of the environment of PV systems. This computational model is implemented by an interactive tool for simulation and visualization. Hence, project planners receive flexible assistance for adjusting the parameters of solar panels amid the planning process and in particular before the installation of a PV system. - Highlights: • Solar panels cause glare that impacts neighborhoods and traffic infrastructures. • Glare might cause disability and discomfort. • 3D environment for the calculation of glare • Interactive tool to simulate and visualize reflections • Impact assessment of solar power plant farms.« less

  5. Visual performance of four simultaneous-image multifocal contact lenses under dim and glare conditions.

    PubMed

    García-Lázaro, Santiago; Ferrer-Blasco, Teresa; Madrid-Costa, David; Albarrán-Diego, César; Montés-Micó, Robert

    2015-01-01

    To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare. In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; Bausch & Lomb], Acuvue Oasys for Presbyopia [AOP; Johnson & Johnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wearing, each subject's binocular distance visual acuity (BDVA) and binocular distance contrast sensitivity (BDCS) were measured using the Functional Visual Analyzer (Stereo Optical Co., Inc.) under mesopic conditions (3 candela [cd]/m) both with no glare and under the 2 levels of induced glare: 1.0 lux (glare 1) and 28 lux (glare 2). Among the SIMCLs, in terms of BDVA, AOAM and PM outperformed BM and AOP. All contact lenses performed better at level without glare, followed by Glare 1, and with the worst results obtained under glare 2. Binocular distance contrast sensitivity revealed statistically significant differences for 12 cycles per degree (cpd). Among the SIMCLs, post hoc multiple comparison testing revealed that AOAM and PM provided the best BDCS at the three luminance levels. In both cases, BDVA and BDCS at 12 cpd, monofocal contact lenses outperformed all SIMCL ones at all lighting conditions. Air Optix Aqua Multifocal and PM provided better visual performance than BM and AOP for distance vision with low addition and under dim conditions, but they all provide worse performance than monofocal contact lenses.

  6. Effects of a blue light-filtering intraocular lens on driving safety in glare conditions.

    PubMed

    Gray, Rob; Hill, Warren; Neuman, Brooke; Houtman, Diane; Potvin, Richard

    2012-05-01

    To evaluate whether the previously established benefit of blue light-filtering intraocular lenses (IOLs) when driving in glare conditions is maintained in patients previously implanted with a blue light-filtering toric IOL. Department of Applied Psychology, Arizona State University, Mesa, Arizona, USA. Comparative case series. The study comprised patients with a blue light-filtering toric IOL (test IOL) or an ultraviolet (UV)-only filtering nontoric IOL (control IOL). All patients had good visual acuity and a valid driver's license. While wearing best spherocylindrical correction, patients performed left-turn maneuvers in front of oncoming traffic in a driving simulator. The safety margin was defined as the time to collision less the time taken to turn at an intersection with oncoming traffic. Measures were repeated with a glare source simulating low-angle sun conditions (daytime driving). Of the 33 evaluable patients, 18 had a test IOL and 15 had a control IOL. In the presence of glare, patients with test IOLs had significantly greater safety margins (mean 2.676 seconds ± 0.438 [SD]) than patients with control IOLs (mean 2.179 ± 0.343 seconds) and significantly lower glare susceptibility (P<.05). In no-glare and glare conditions, patients with test IOLs had significantly lower glare susceptibility than patients with control IOLs. The blue light-filtering toric IOL produced a significantly greater reduction in glare disability than the UV-only filtering nontoric IOL and increased the ability of drivers to safely execute left turns in low-sun conditions. Dr. Houtman is an employee of Alcon Laboratories, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. The mechanical behavior of GLARE laminates for aircraft structures

    NASA Astrophysics Data System (ADS)

    Wu, Guocai; Yang, J.-M.

    2005-01-01

    GLARE (glass-reinforced aluminum laminate) is a new class of fiber metal laminates for advanced aerospace structural applications. It consists of thin aluminum sheets bonded together with unidirectional or biaxially reinforced adhesive prepreg of high-strength glass fibers. GLARE laminates offer a unique combination of properties such as outstanding fatigue resistance, high specific static properties, excellent impact resistance, good residual and blunt notch strength, flame resistance and corrosion properties, and ease of manufacture and repair. GLARE laminates can be tailored to suit a wide variety of applications by varying the fiber/resin system, the alloy type and thickness, stacking sequence, fiber orientation, surface pretreatment technique, etc. This article presents a comprehensive overview of the mechanical properties of various GLARE laminates under different loading conditions.

  8. Effects of planar and non-planar driver-side mirrors on age-related discomfort-glare responses

    PubMed Central

    Lockhart, Thurmon E.; Atsumi, Bunji; Ghosh, Arka; Mekaroonreung, Haruetai; Spaulding, Jeremy

    2010-01-01

    In this study, we evaluated subjective nighttime discomfort-glare responses on three different types of planar and non-planar driver-side mirrors on two age groups. Fifty-six individuals (28 young [18–35 years] and 28 old [65 years and over]) participated in this experiment. Subjective discomfort-glare rating scores on three different types of driver-side mirrors were assessed utilizing De Boer's rating scale in a controlled nighttime driving environment (laboratory ambient illuminant level—l lux with headlight turned off). Three driver-side mirrors included planar “flat mirror”: radius of curvature 242650.92 mm, reflectivity 0.60114, and surface reflectance 0.60568; “curved mirror”: radius of curvature 1433.3 mm, reflectivity 0.21652, and surface reflectance 0.58092; “blue mirror”: radius of curvature 1957.1 mm, reflectivity 0.25356, and surface reflectance 0.54585. The results indicated that with the same glare level (as measured by angle of incidence and illuminance in front of the eyes), older adults reported worse feelings of glare than their younger counterparts. Furthermore, the results indicated that both young and older adults reported worse feelings of glare for planar driver-side mirror than non-planar driver-side mirrors. These results suggest that older adults' criterion of discomfort-glare is more sensitive than their younger counterparts, and importantly, the non-planar driver-side mirrors can be beneficial in terms of reducing nighttime discomfort-glare for both the young and the elderly. PMID:20582252

  9. META-GLARE: a shell for CIG systems.

    PubMed

    Bottrighi, Alessio; Rubrichi, Stefania; Terenziani, Paolo

    2015-01-01

    In the last twenty years, many different approaches to deal with Computer-Interpretable clinical Guidelines (CIGs) have been developed, each one proposing its own representation formalism (mostly based on the Task-Network Model) execution engine. We propose META-GLARE a shell for easily defining new CIG systems. Using META-GLARE, CIG system designers can easily define their own systems (basically by defining their representation language), with a minimal programming effort. META-GLARE is thus a flexible and powerful vehicle for research about CIGs, since it supports easy and fast prototyping of new CIG systems.

  10. ColorChecker at the beach: dangers of sunburn and glare

    NASA Astrophysics Data System (ADS)

    McCann, John

    2014-01-01

    In High-Dynamic-Range (HDR) imaging, optical veiling glare sets the limits of accurate scene information recorded by a camera. But, what happens at the beach? Here we have a Low-Dynamic-Range (LDR) scene with maximal glare. Can we calibrate a camera at the beach and not be burnt? We know that we need sunscreen and sunglasses, but what about our cameras? The effect of veiling glare is scene-dependent. When we compare RAW camera digits with spotmeter measurements we find significant differences. As well, these differences vary, depending on where we aim the camera. When we calibrate our camera at the beach we get data that is valid for only that part of that scene. Camera veiling glare is an issue in LDR scenes in uniform illumination with a shaded lens.

  11. Effect of glare on reaction time for peripheral vision at mesopic adaptation.

    PubMed

    Aguirre, Rolando C; Colombo, Elisa M; Barraza, José F

    2011-10-01

    When a bright light is present in the field of view, visibility is dramatically reduced. Many studies have investigated the effect of glare on visibility considering foveal vision. However, the effects on peripheral vision have received little attention. In a previous work [J. Opt. Soc. Am. A 25, 1790 (2008)], we showed that the effect of glare on reaction time (RT) for foveal vision at mesopic adaptation depends on the stimulus spatial frequency. In this work, we extend this study to peripheral vision. We measured the RT of achromatic sinusoidal gratings as a function of contrast for a range of spatial frequency, and eccentricity, and for two glare levels, in addition to the no-glare condition. Data were fitted with Piéron's law, following a linear relationship. We found that glare increases the slope of these lines for all conditions. These slopes seem to depend critically on eccentricity for 4 cycles/degree (c/deg), but not for 1 and 2 c/deg. We explain our results in terms of the contrast sensitivity (gain) of the underlying detection mechanisms.

  12. The Pattern Glare Test: a review and determination of normative values.

    PubMed

    Evans, B J W; Stevenson, S J

    2008-07-01

    Pattern glare is characterised by symptoms of visual perceptual distortions and visual stress on viewing striped patterns. People with migraine or Meares-Irlen syndrome (visual stress) are especially prone to pattern glare. The literature on pattern glare is reviewed, and the goal of this study was to develop clinical norms for the Wilkins and Evans Pattern Glare Test. This comprises three test plates of square wave patterns of spatial frequency 0.5, 3 and 12 cycles per degree (cpd). Patients are shown the 0.5 cpd grating and the number of distortions that are reported in response to a list of questions is recorded. This is repeated for the other patterns. People who are prone to pattern glare experience visual perceptual distortions on viewing the 3 cpd grating, and pattern glare can be quantified as either the sum of distortions reported with the 3 cpd pattern or as the difference between the number of distortions with the 3 and 12 cpd gratings, the '3-12 cpd difference'. In study 1, 100 patients consulting an optometrist performed the Pattern Glare Test and the 95th percentile of responses was calculated as the limit of the normal range. The normal range for the number of distortions was found to be <4 on the 3 cpd grating and <2 for the 3-12 cpd difference. Pattern glare was similar in both genders but decreased with age. In study 2, 30 additional participants were given the test in the reverse of the usual testing order and were compared with a sub-group from study 1, matched for age and gender. Participants experienced more distortions with the 12 cpd grating if it was presented after the 3 cpd grating. However, the order did not influence the two key measures of pattern glare. In study 3, 30 further participants who reported a medical diagnosis of migraine were compared with a sub-group of the participants in study 1 who did not report migraine or frequent headaches, matched for age and gender. The migraine group reported more symptoms on viewing all gratings, particularly the 3 cpd grating. The only variable to be significantly different between the groups was the 3-12 cpd difference. In conclusion, people have an abnormal degree of pattern glare if they have a Pattern Glare Test score of >3 on the 3 cpd grating or a score of >1 on the 3-12 cpd difference. The literature suggests that these people are likely to have visual stress in everyday life and may therefore benefit from interventions designed to alleviate visual stress, such as precision tinted lenses.

  13. 76 FR 51954 - Procurement List Additions And Deletions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-19

    ...Phone NSN: 7045-00-NIB-0327--Glare Shield for Blackberry Bold NSN: 7045-00-NIB-0328--Glare Shield for Blackberry Storm2 NSN: 7045-00-NIB-0329--Universal PDA Glare Shield NSN: 7045-00-NIB-0330--Privacy Shield for iPhone NSN: 7045-00-NIB-0331--Privacy Shield for Blackberry Bold NSN: 7045-00-NIB-0332--Privacy...

  14. 77 FR 27118 - Safety Zone; Rocketts Red Glare Fireworks, Ancarrows Landing Park, James River, Richmond, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-09

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2012-0114] RIN 1625-AA00 Safety Zone; Rocketts Red Glare Fireworks, Ancarrows Landing Park, James River, Richmond, VA... Glare Fireworks, Ancarrows Landing Park, James River, Richmond, VA in the Federal Register (76 FR 13525...

  15. 3D Finite Element Modelling of Cutting Forces in Drilling Fibre Metal Laminates and Experimental Hole Quality Analysis

    NASA Astrophysics Data System (ADS)

    Giasin, Khaled; Ayvar-Soberanis, Sabino; French, Toby; Phadnis, Vaibhav

    2017-02-01

    Machining Glass fibre aluminium reinforced epoxy (GLARE) is cumbersome due to distinctively different mechanical and thermal properties of its constituents, which makes it challenging to achieve damage-free holes with the acceptable surface quality. The proposed work focuses on the study of the machinability of thin ( 2.5 mm) GLARE laminate. Drilling trials were conducted to analyse the effect of feed rate and spindle speed on the cutting forces and hole quality. The resulting hole quality metrics (surface roughness, hole size, circularity error, burr formation and delamination) were assessed using surface profilometry and optical scanning techniques. A three dimensional (3D) finite-element (FE) model of drilling GLARE laminate was also developed using ABAQUS/Explicit to help understand the mechanism of drilling GLARE. The homogenised ply-level response of GLARE laminate was considered in the FE model to predict cutting forces in the drilling process.

  16. Why HID headlights bother older drivers

    PubMed Central

    Mainster, M A; Timberlake, G T

    2003-01-01

    Driving requires effective coordination of visual, motor, and cognitive skills. Visual skills are pushed to their limit at night by decreased illumination and by disabling glare from oncoming headlights. High intensity discharge (HID) headlamps project light farther down roads, improving their owner’s driving safety by increasing the time available for reaction to potential problems. Glare is proportional to headlamp brightness, however, so increasing headlamp brightness also increases potential glare for oncoming drivers, particularly on curving two lane roads. This problem is worse for older drivers because of their increased intraocular light scattering, glare sensitivity, and photostress recovery time. An analysis of automobile headlights, intraocular stray light, glare, and night driving shows that brightness rather than blueness is the primary reason for the visual problems that HID headlights can cause for older drivers who confront them. The increased light projected by HID headlights is potentially valuable, but serious questions remain regarding how and where it should be projected. PMID:12488274

  17. Solar Glare Hazard Analysis Tool v. 4.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Clifford L.; Sims, Cianan

    SGHAT predicts the occurrence and intensity of glare caused by a user-specified solar panel array when viewed from one or more observation points. An interactive mapping interface is used to determine the latitude, longitude and elevation of the array and observation points. The presence and intensity of glare is then calculated along a given time interval throughout the year, based on the position of the sun. The potential ocular hazard is also reported. The maximum energy production of the solar array is also estimated so that alternative designs can be compared to determine the design that yields the most energymore » production while mitigating glare.« less

  18. [Scattered light and glare sensitivity after wavefront-guided photorefractive keratectomy (WFG-PRK) and laser in situ keratomileusis (WFG-LASIK)].

    PubMed

    Vignal, R; Tanzer, D; Brunstetter, T; Schallhorn, S

    2008-05-01

    To compare glare sensitivity measured by the intraocular scattered light between WFG-PRK and WFG-LASIK at 12 months follow-up and to assess its correlation to patients' complaints. Prospective and randomized study on 13 patients treated with WFG-LASIK, 13 patients with WFG-PRK and a control group of 35 patients. The intraocular stray light was measured by the Oculus C-Quant 12 months after surgery and before surgery for the control group. Photopic and mesopic contrast acuity and glare symptoms were reported pre- and postoperatively. Stray light values were normal in 79% of patients after WFG-LASIK and PRK and 86% in the control group, with mean values of 1.05 log, 1.03 log, and 0.99 log, respectively (p>0.05). All the patients with significant glare complaints had impaired stray light values versus 31.5% in the no-complaint group. Photopic and mesopic contrast acuity and glare symptoms were improved 1 year after surgery compared to preoperatively (no significant difference between groups). WFG-LASIK and PRK are safe and equivalent procedures regarding quality of vision. The measurement of stray light can be a discriminative test to assessing patients' glare complaints.

  19. Impact Resistance of Lightweight Hybrid Structures for Gas Turbine Engine Fan Containment Applications

    NASA Technical Reports Server (NTRS)

    Hebsur, Mohan G.; Noebe, Ronald D.; Revilock, Duane M.

    2003-01-01

    The ballistic impact resistance of hybrid composite sandwich structures was evaluated with the ultimate goal of developing new materials or structures for potential gas turbine engine fan containment applications. The sandwich structures investigated consisted of GLARE-5 laminates as face sheets with lightweight cellular metallic materials such as honeycomb, foam, and lattice block as a core material. The impact resistance of these hybrid sandwich structures was compared to GLARE-5 laminates and 2024-T3 Al sheet, which were tested as a function of areal weight (material thickness). The GLARE-5 laminates exhibited comparable impact properties to that of 2024-T3 Al at low areal weights, even though there were significant differences in the static tensile properties of these materials. The GLARE-5, however, did have a greater ballistic limit than straight aluminum sheet at higher areal weights. Furthermore, there is up to a 25% advantage in ballistic limit for the GLARE-5/foam sandwich structures compared to straight 2024-T3 Al. But no advantage in ballistic limit was observed between any of the hybrid sandwich structures and thicker versions of GLARE-5. Recommendations for future work are provided, based on these preliminary data.

  20. Effect of a modified optic edge design on visual function: textured-edge versus round-anterior, slope-side edge.

    PubMed

    Hayashi, Ken; Hayashi, Hideyuki

    2004-08-01

    To compare the impairment in visual function caused by glare with 2 acrylic intraocular lenses (IOLs) with different modified optic edges. Hayashi Eye Hospital, Fukuoka, Japan. Fifty-four patients had implantation of an IOL with a textured edge (Alcon MA60AC) in 1 eye and an IOL with a round-anterior, sloped-sided edge (AMO AR40e) in the opposite eye. Visual acuity was measured at 5 contrast visual targets (100%, 25%, 10%, 5%, and 2.5%) (contrast visual acuity) under photopic and mesopic conditions with and without a glare source approximately 1 month after surgery using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000). The mean mesopic contrast visual acuity at moderate- to low-contrast visual targets was significantly worse in the presence of a glare source in both groups, whereas photopic contrast visual acuity did not change significantly. There were no significant differences between the 2 groups in the mean visual acuity or in photopic or mesopic lighting contrast visual acuity with and without a glare source. Furthermore, there was no significant difference in loss of contrast visual acuity in the presence of glare. Mesopic contrast sensitivity with both acrylic IOLs was impaired significantly in the presence of glare, but the impairment of contrast sensitivity from glare was approximately the same between eyes with a textured-edge IOL and eyes with a round-anterior, sloped-sided edge IOL.

  1. META-GLARE: A meta-system for defining your own computer interpretable guideline system-Architecture and acquisition.

    PubMed

    Bottrighi, Alessio; Terenziani, Paolo

    2016-09-01

    Several different computer-assisted management systems of computer interpretable guidelines (CIGs) have been developed by the Artificial Intelligence in Medicine community. Each CIG system is characterized by a specific formalism to represent CIGs, and usually provides a manager to acquire, consult and execute them. Though there are several commonalities between most formalisms in the literature, each formalism has its own peculiarities. The goal of our work is to provide a flexible support to the extension or definition of CIGs formalisms, and of their acquisition and execution engines. Instead of defining "yet another CIG formalism and its manager", we propose META-GLARE (META Guideline Acquisition, Representation, and Execution), a "meta"-system to define new CIG systems. In this paper, META-GLARE, a meta-system to define new CIG systems, is presented. We try to capture the commonalities among current CIG approaches, by providing (i) a general manager for the acquisition, consultation and execution of hierarchical graphs (representing the control flow of actions in CIGs), parameterized over the types of nodes and of arcs constituting it, and (ii) a library of different elementary components of guidelines nodes (actions) and arcs, in which each type definition involves the specification of how objects of this type can be acquired, consulted and executed. We provide generality and flexibility, by allowing free aggregations of such elementary components to define new primitive node and arc types. We have drawn several experiments, in which we have used META-GLARE to build a CIG system (Experiment 1 in Section 8), or to extend it (Experiments 2 and 3). Such experiments show that META-GLARE provides a useful and easy-to-use support to such tasks. For instance, re-building the Guideline Acquisition, Representation, and Execution (GLARE) system using META-GLARE required less than one day (Experiment 1). META-GLARE is a meta-system for CIGs supporting fast prototyping. Since META-GLARE provides acquisition and execution engines that are parametric over the specific CIG formalism, it supports easy update and construction of CIG systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Glare effect for three types of street lamps based on White LEDs

    NASA Astrophysics Data System (ADS)

    Sun, Ching-Cherng; Jiang, Chong-Jhih; Chen, Yi-Chun; Yang, Tsung-Hsun

    2014-05-01

    This study is aimed to assess the glare effect from LED-based street lamps with three general optical designs, which are cluster LEDs with a single lens, a LED array accompany with a lens array, and a tilted LED array, respectively. Observation conditions were simulated based on various locations and viewing axes. Equivalent luminance calculations were used to reveal the glare levels of the three designs. The age effect for the calculated equivalent luminance was also examined for human eyes of people at the age of 40 or 60. The results demonstrate that among the three design types, a LED array accompany with a lens array causes relatively smaller glare for most viewing conditions.

  3. The forward masking effects of low-level laser glare on target location performance in a visual search task

    NASA Astrophysics Data System (ADS)

    Reddix, M. D.; Dandrea, J. A.; Collyer, P. D.

    1992-01-01

    The present study examined the effects of low-intensity laser glue, far below a level that would cause ocular damage or flashblindness, on the visually guided performance of aviators. With a forward-masking paradigm, this study showed that the time at which laser glare is experienced, relative to initial acquisition of visual information, differentially affects the speed and accuracy of target-location performance. Brief exposure (300 ms) to laser glare, terminating with a visual scene's onset, produced significant decrements in target-location performance relative to a no-glare control whereas a 150 and 300-ms delay of display onset (DDO) had very little effect. The intensity of the light entering the eye and producing these effects was far below the Maximum Permissible Exposure (MPE) limit for safe viewing of coherent light produced by an argon laser. In addition, these effects were modulated by the distance of the target from the center of the visual display. This study demonstrated that the presence of laser glare is not sufficient, in and of itself, to diminish target-location performance. The time at which laser glare is experienced is an important factor in determining the probability and extent of visually mediated performance decrements.

  4. Optical functional performance of the osteo-odonto-keratoprosthesis.

    PubMed

    Lee, Richard M H; Ong, Gek L; Lam, Fook Chang; White, Joy; Crook, David; Liu, Christopher S C; Hull, Chris C

    2014-10-01

    The aim of this study was to evaluate optical and visual functional performance of the osteo-odonto-keratoprosthesis (OOKP). Optical design and analysis was performed with customized optical design software. Nine patients with implanted OOKP devices and 9 age-matched control patients were assessed. Contrast sensitivity was assessed and glare effect was measured with a brightness acuity test. All OOKP patients underwent kinetic Goldmann perimetry and wavefront aberrometry and completed the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25). Optical analysis showed that the optical cylinder is near diffraction-limited. A reduction in median visual acuity (VA) with increasing glare settings was observed from 0.04 logMAR (without glare) to 0.20 logMAR (with glare at "high" setting) and significantly reduced statistically when compared with the control group at all levels of glare (P < 0.05). Contrast sensitivity was significantly reduced when compared with age-matched controls at medium and high spatial frequencies (P < 0.05). Median Goldmann perimetry was 65 degrees (interquartile range, 64-74 degrees; V-4e isopters) and 69 degrees excluding 2 glaucomatous subjects. Several vision-related NEI VFQ-25 subscales correlated significantly with VA at various brightness acuity test levels and contrast sensitivity at medium spatial frequencies, including dependency, general vision, near activities and distance activities. The OOKP optical cylinder provides patients with a good level of VA that is significantly reduced by glare. We have shown in vivo that updates to the optical cylinder design have improved the patient's field of view. Reduction of glare and refinement of cylinder alignment methods may further improve visual function and patient satisfaction.

  5. Glare disability and driving safety.

    PubMed

    Babizhayev, M A

    2003-01-01

    Increasing investigation of the visual elements of safe driving environments may be of great benefit to society. Visual disability appears to be only one of many visual factors related to traffic accidents. The purpose of this article was to examine the type of visual impairment mediated by the increased glare sensitivity in adult drivers using the original halometer glare test. In this article, the visual sensory, cognitive and motor functions relevant to driving, their measurement, the epidemiology and prevention of age-associated functional impairments and the relationship of functional impairments to both self-reported driving and the imposition of legal restrictions are reviewed. The problem of night and tunnel driving is the most urgent in relation to the effects of glare from vehicle headlights on motion perception of drivers. The reduced mesopic vision and increased sensitivity to glare are accompanied by an increased risk of nighttime accidents. Elderly drivers and patients with beginning cataract cannot sufficiently fulfill the criteria for night driving ability because of contrast and glare sensitivity. It is indispensable for the parameters mentioned to be carefully measured and for drivers to be informed that night driving ability may be impaired, even if visual acuity is sufficient. It would be advisable for traffic safety if simple tests for contrast and glare sensitivity were implemented for vehicles and/or were regularly added to the requirements for a driver's licence, at least for older drivers. The age, functional status and test result limits should be defined to avoid a risk factor in traffic. Copyright 2003 S. Karger AG, Basel

  6. A real-time monitoring system for night glare protection

    NASA Astrophysics Data System (ADS)

    Ma, Jun; Ni, Xuxiang

    2010-11-01

    When capturing a dark scene with a high bright object, the monitoring camera will be saturated in some regions and the details will be lost in and near these saturated regions because of the glare vision. This work aims at developing a real-time night monitoring system. The system can decrease the influence of the glare vision and gain more details from the ordinary camera when exposing a high-contrast scene like a car with its headlight on during night. The system is made up of spatial light modulator (The liquid crystal on silicon: LCoS), image sensor (CCD), imaging lens and DSP. LCoS, a reflective liquid crystal, can modular the intensity of reflective light at every pixel as a digital device. Through modulation function of LCoS, CCD is exposed with sub-region. With the control of DSP, the light intensity is decreased to minimum in the glare regions, and the light intensity is negative feedback modulated based on PID theory in other regions. So that more details of the object will be imaging on CCD and the glare protection of monitoring system is achieved. In experiments, the feedback is controlled by the embedded system based on TI DM642. Experiments shows: this feedback modulation method not only reduces the glare vision to improve image quality, but also enhances the dynamic range of image. The high-quality and high dynamic range image is real-time captured at 30hz. The modulation depth of LCoS determines how strong the glare can be removed.

  7. Some Inspection Methods for Quality Control and In-service Inspection of GLARE

    NASA Astrophysics Data System (ADS)

    Sinke, J.

    2003-07-01

    Quality control of materials and structures is an important issue, also for GLARE. During the manufacturing stage the processes and materials should be monitored and checked frequently in order to obtain a qualified product. During the operation of the aircraft, frequent monitoring and inspections are performed to maintain the quality at a prescribed level. Therefore, in-service inspection methods are applied, and when necessary repair activities are conducted. For the quality control of the GLARE panels and components during manufacturing, the C-scan method proves to be an effective tool. For in-service inspection the Eddy Current Method is one of the suitable options. In this paper a brief overview is presented of both methods and their application on GLARE products.

  8. Determining the refractive index of particles using glare-point imaging technique

    NASA Astrophysics Data System (ADS)

    Meng, Rui; Ge, Baozhen; Lu, Qieni; Yu, Xiaoxue

    2018-04-01

    A method of measuring the refractive index of a particle is presented from a glare-point image. The space of a doublet image of a particle can be determined with high accuracy by using auto-correlation and Gaussian interpolation, and then the refractive index is obtained from glare-point separation, and a factor that may influence the accuracy of glare-point separation is explored. Experiments are carried out for three different kinds of particles, including polystyrene latex particles, glass beads, and water droplets, whose measuring accuracy is improved by the data fitting method. The research results show that the method presented in this paper is feasible and beneficial to applications such as spray and atmospheric composition measurements.

  9. Alicen Kandt | NREL

    Science.gov Websites

    energy uses of water infrastructure Glint/glare impacts associated with photovoltaic systems Technical Report (2016) Mitigating the Impacts of Glint and Glare, Military Journal (2015) View all NREL

  10. Quantitative evaluation research of glare from automotive headlamps

    NASA Astrophysics Data System (ADS)

    Wang, Tiecheng; Qian, Rui; Cao, Ye; Gao, Mingqiu

    2018-01-01

    This study concerns the quantized evaluation research of glare from automotive headlamps. In the actual regulations, only one point in the test screen is set for judging whether driver can bear the light caused by headlamps of opposing vehicle. To evaluating practical effect of glare, we accept a glare zone with the probability distribution information of the oncoming driver's eye position. In this focus area, glare level of headlamp is represented by weighted luminous flux. To confirm the most comfortable illuminance value to human eyes at 50 m, we used test point B50L as observation position, and collected 1,000 subjective evaluation data from 20 test personnel in different ages during two months. Basing on the assessment results, we calculated 0.60 lx as recommended value for standardized testing procedure at 25 m. Then we figured out 0.38 lm as optimum value, and 0.25 / 1.20 lm as limiting values depending on regulations. We tested 40 sample vehicles with different levels to verify the sectional nonlinear quantitative evaluation method we designed, and analyzed the typical test results.

  11. Identification of the source of permanent glare from a three-piece IOL.

    PubMed

    Wolffe, M; Landry, R J; Alpar, J J

    2007-08-01

    To identify the source of unwanted glare images from a three-piece intraocular lens (IOL) implant following cataract surgery. The IOL and posterior capsule were examined under mydriatic and nonmydriatic conditions using direct focal illumination from a slit lamp biomicroscope. Direct focal illumination was undertaken with both a narrow beam (0.1 mm in width) and small spot (0.1 mm in diameter) to identify the points at which the glare images were stimulated. While observing the location of the beam with the slit lamp biomicroscope, the patient indicated when the glare images were stimulated. The nasal haptic insertion into the optic was identified as the source of temporal line images arising from lights such as headlamps from oncoming cars and street lamps. The adjacent edge of the IOL was also identified as the likely source of additional cob web-like light rays. The haptic insertions in three-piece IOLs may, under certain conditions, interfere with light entering the pupil and produce extraneous images. Large mesopic pupils and decentred IOLs are conditions that increase the likelihood of unwanted glare images.

  12. Effect of variable tinted spectacle lenses on visual performance in control subjects.

    PubMed

    Lee, Jason E; Stein, Jonathan J; Prevor, Meredith B; Seiple, William H; Holopigian, Karen; Greenstein, Vivienne C; Stenson, Susan M

    2002-04-01

    To evaluate quantitatively the effects of tinted spectacle lenses on visual performance in individuals without visual pathology. Twenty-five subjects were assessed by measuring contrast sensitivity with and without glare. Gray, brown, yellow, green, purple, and blue lens tints were evaluated. Measurements were repeated with each lens tint and with a clear lens, and the order was counterbalanced within and between subjects. Glare was induced with a modified brightness acuity tester. All subjects demonstrated an increase in contrast thresholds under glare conditions for all lens tints. However, purple and blue lens tints resulted in the least amount of contrast threshold increase; the yellow lens tint resulted in the largest contrast threshold increase. Purple and blue lens tints may improve contrast sensitivity in control subjects under glare conditions.

  13. Effect of Direct Glare on Orbicularis Oculi and Trapezius During Computer Reading.

    PubMed

    Mork, Randi; Bruenech, Jan Richard; Thorud, Hanne Mari Schiøtz

    2016-07-01

    Unfavorable visual conditions during computer work may affect development of both eyestrain and musculoskeletal pain in the neck and shoulder area. The aim of the study was to investigate how direct glare affects symptom development, muscle activity, and muscle blood flow in m. orbicularis oculi and m. trapezius during reading on a computer screen. Fifteen healthy young adults with normal binocular vision read text on a computer screen at an optimized computer workplace, 30 minutes with glare exposure and 30 minutes with appropriate lighting. Postural angles were continuously registered. Development of eye symptoms and musculoskeletal pain in the neck and shoulder area were recorded using VAS scales. Muscle activity and muscle blood flow were measured continuously using electromyography and photoplethysmography, respectively. Glare exposure resulted in significantly more pronounced eye pain, increased orbicularis muscle activity, and increased trapezius blood flow compared to reading with appropriate lighting. There were no significant differences in posture between the two light conditions. There were also significant associations between orbicularis oculi activity and both trapezius blood flow and neck pain during both conditions. Results from the current study show that direct glare conditions cause increased eyestrain and orbicularis oculi contraction during reading on a computer screen. This study also indicates that exposure to direct glare affects the trapezius muscle, possibly by an interaction between the visual system, sympathetic nervous system, and head-stabilizing muscles. In addition, there were associations between the use of orbicularis oculi, trapezius blood flow, and development of neck pain independent of the lighting.

  14. Computation of glint, glare, and solar irradiance distribution

    DOEpatents

    Ho, Clifford Kuofei; Khalsa, Siri Sahib Singh

    2017-08-01

    Described herein are technologies pertaining to computing the solar irradiance distribution on a surface of a receiver in a concentrating solar power system or glint/glare emitted from a reflective entity. At least one camera captures images of the Sun and the entity of interest, wherein the images have pluralities of pixels having respective pluralities of intensity values. Based upon the intensity values of the pixels in the respective images, the solar irradiance distribution on the surface of the entity or glint/glare corresponding to the entity is computed.

  15. Computation of glint, glare, and solar irradiance distribution

    DOEpatents

    Ho, Clifford Kuofei; Khalsa, Siri Sahib Singh

    2015-08-11

    Described herein are technologies pertaining to computing the solar irradiance distribution on a surface of a receiver in a concentrating solar power system or glint/glare emitted from a reflective entity. At least one camera captures images of the Sun and the entity of interest, wherein the images have pluralities of pixels having respective pluralities of intensity values. Based upon the intensity values of the pixels in the respective images, the solar irradiance distribution on the surface of the entity or glint/glare corresponding to the entity is computed.

  16. Numerical investigation of the effect of delaminations on fracture characteristics of glare

    NASA Astrophysics Data System (ADS)

    Bhat, Sunil; Narayanan, S.

    2013-10-01

    A finite element examination of the effect of delaminations on fracture characteristics of fibre metal laminate (Glare), by comparing energy release rates of normal cracks in laminates with and without delaminations, is presented in the paper. Glare comprising thin cracked 2024-T3 aerospace aluminum alloy layers alternately bonded with E-glass fibre based composite prepregs is considered for the analysis. Delaminations are modeled with interface cohesive elements. Energy release rates of normal cracks in laminates with delaminations are found to be higher than those in the laminates without delaminations.

  17. Mechanical behavior, damage tolerance and durability of fiber metal laminates for aircraft structures

    NASA Astrophysics Data System (ADS)

    Wu, Guocai

    This study systematically explores the mechanical behavior, damage tolerance and durability of fiber metal laminates, a promising candidate materials system for next generation aerospace structures. The experimental results indicated that GLARE laminates exhibited a bilinear deformation behavior under static in-plane loading. Both an analytical constitutive model based on a modified classical lamination theory which incorporates the elasto-plastic behavior of aluminum alloy and a numerical simulation based on finite element modeling are used to predict the nonlinear stress-strain response and deformation behavior of GLARE laminates. The blunt notched strength of GLARE laminates increased with decreasing specimen width and decreasing hole diameter. The notched strength of GLARE laminates was evaluated based on a modified point stress criterion. A computer simulation based on finite element method was performed to study stress concentration and distribution around the notch and verify the analytical and experimental results of notched strength. Good agreement is obtained between the model predictions and experimental results. Experimental results also indicate that GLARE laminates exhibited superior impact properties to those of monolithic 2024-T3 aluminum alloy at low velocity impact loading. The GLARE 5-2/1 laminate with 0°/90°/90°/0° fiber configuration exhibits a better impact resistance than the GLARE 4-3/2 laminate with 0°/90°/0° fiber orientation. The characteristic impact energies, the damage area, and the permanent deflection of laminates are used to evaluate the impact damage resistance. The post-impact residual tensile strength under various damage states ranging from the plastic dent, barely visible impact damage (BVID), clearly visible impact damage (CVID) up to the complete perforation was also measured and compared. The post-impact fatigue behavior under various stress levels and impact damage states was extensively explored. The damage initiation and progression, failure modes and crack propagation under different loading conditions were investigated and identified with microscopy, SEM, X-ray radiography, and by chemically removing outer aluminum layers.

  18. A note on image degradation, disability glare, and binocular vision

    NASA Astrophysics Data System (ADS)

    Rajaram, Vandana; Lakshminarayanan, Vasudevan

    2013-08-01

    Disability glare due to scattering of light causes a reduction in visual performance due to a luminous veil over the scene. This causes problem such as contrast detection. In this note, we report a study of the effect of this veiling luminance on human stereoscopic vision. We measured the effect of glare on the horopter measured using the apparent fronto-parallel plane (AFPP) criterion. The empirical longitudinal horopter measured using the AFPP criterion was analyzed using the so-called analytic plot. The analytic plot parameters were used for quantitative measurement of binocular vision. Image degradation plays a major effect on binocular vision as measured by the horopter. Under the conditions tested, it appears that if vision is sufficiently degraded then the addition of disability glare does not seem to significantly cause any further compromise in depth perception as measured by the horopter.

  19. Evaluation of flexible plastic glare shield in Oregon.

    DOT National Transportation Integrated Search

    1981-05-01

    This experimental features project was approved by the Department of Transportation, Federal Highway Administration, on July 11, 1973. A four-mile section of flexible plastic glare screen was installed on top of the existing concrete median barrier o...

  20. Objective and automated measurement of dynamic vision functions

    NASA Technical Reports Server (NTRS)

    Flom, M. C.; Adams, A. J.

    1976-01-01

    A phoria stimulus array and electro-oculographic (EOG) arrangements for measuring motor and sensory responses of subjects subjected to stress or drug conditions are described, along with experimental procedures. Heterophoria (as oculomotor function) and glare recovery time (time required for photochemical and neural recovery after exposure to a flash stimulus) are measured, in research aimed at developing automated objective measurement of dynamic vision functions. Onset of involuntary optokinetic nystagmus in subjects attempting to track moving stripes (while viewing through head-mounted binocular eyepieces) after exposure to glare serves as an objective measure of glare recovery time.

  1. Rainbow glare by retinal imaging

    NASA Astrophysics Data System (ADS)

    Sun, Han-Ying; Chiang, Yao-Ting; Yeh, Shang-Min; Huang, Shuan-Yu; Horng, Chi-Ting; Wang, Hsiang-Chen

    2016-07-01

    This study aims to determine whether IntraLase surgery can cause rainbow glare. Monte-Carlo ray tracing method is used to study visual conditions of an ordered microstructure array on the cornea. A corneal flap in the simulated eye model can generate numerous microbubbles caused by IntraLase surgery. Moreover, this study evaluates the visual performance under different conditions such as the size and interval of the microbubble structure on the cornea with vary incident angles and diameters of light. The results of this study can help elucidate the real cause of rainbow glare as a side effect of IntraLase.

  2. PHLUX: Photographic Flux Tools for Solar Glare and Flux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2010-12-02

    A web-based tool to a) analytically and empirically quantify glare from reflected light and determine the potential impact (e.g., temporary flash blindness, retinal burn), and b) produce flux maps for central receivers. The tool accepts RAW digital photographs of the glare source (for hazard assessment) or the receiver (for flux mapping), as well as a photograph of the sun for intensity and size scaling. For glare hazard assessment, the tool determines the retinal irradiance (W/cm2) and subtended source angle for an observer and plots the glare source on a hazard spectrum (i.e., low-potential for flash blindness impact, potential for flashmore » blindness impact, retinal burn). For flux mapping, the tool provides a colored map of the receiver scaled by incident solar flux (W/m2) and unwraps the physical dimensions of the receiver while accounting for the perspective of the photographer (e.g., for a flux map of a cylindrical receiver, the horizontal axis denotes receiver angle in degrees and the vertical axis denotes vertical position in meters; for a flat panel receiver, the horizontal axis denotes horizontal position in meters and the vertical axis denotes vertical position in meters). The flux mapping capability also allows the user to specify transects along which the program plots incident solar flux on the receiver.« less

  3. Manufacturing of GLARE Parts and Structures

    NASA Astrophysics Data System (ADS)

    Sinke, J.

    2003-07-01

    GLARE is a hybrid material consisting of alternating layers of metal sheets and composite layers, requiring special attention when manufacturing of parts and structures is concerned. On one hand the applicable manufacturing processes for GLARE are limited, on the other hand, due to the constituents and composition of the laminate, it offers new opportunities for production. One of the opportunities is the manufacture of very large skin panels by lay-up techniques. Lay-up techniques are common for full composites, but uncommon for metallic structures. Nevertheless, large GLARE skin panels are made by lay-up processes. In addition, the sequences of forming and laminating processes, that can be selected, offer manufacturing options that are not applicable to metals or full composites. With respect to conventional manufacturing processes, the possibilities for Fibre Metal Laminates in general, are limited. The limits are partly due to the different failure modes, partly due to the properties of the constituents in the laminate. For machining processes: the wear of the cutting tools during machining operations of GLARE stems from the abrasive nature of the glass fibres. For the forming processes: the limited formability, expressed by a small failure strain, is related to the glass fibres. However, although these manufacturing issues may restrict the use of manufacturing processes for FMLs, application of these laminates in aircraft is not hindered.

  4. Development of a human eye model incorporated with intraocular scattering for visual performance assessment

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Chun; Jiang, Chong-Jhih; Yang, Tsung-Hsun; Sun, Ching-Cherng

    2012-07-01

    A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of volumetric Mie scattering in the cornea and the crystalline lens, and a diffusive-surface model at the retina fundus. The retina was regarded as a Lambertian surface and was assigned its corresponding reflectance at each wavelength. The optical performance of the eye model was evaluated in CodeV and ASAP and presented by the modulation transfer functions at single and multiple wavelengths. The chromatic optical powers obtained from this model resembled that of the average physiological eyes. The scattering property was assessed by means of glare veiling luminance and compared with the CIE general disability glare equation. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated to compare with the normal disability glare curve. This model has high potential for investigating visual performance in ordinary lighting and display conditions and under the influence of glare sources.

  5. Eliminating sun glare disturbance at signalized intersections by a vehicle to infrastructure wireless communication : final report.

    DOT National Transportation Integrated Search

    2016-05-01

    Due to sun glare disturbances, drivers may encounter fatal threats on roadways, particularly at signalized intersections. Many studies have attempted to develop applicable solutions, such as avoiding sun positions, road geometric redirections, and we...

  6. Evaluation of a fiberglass instrument glare shield for protection against head injury.

    DOT National Transportation Integrated Search

    1972-02-01

    An all fiberglass prototype glare shield has been evaluated in terms of head injury protection. In 30-ft./sec. head impacts, a protrusion is designed to fold down over the heavy instruments, offering significant improvement in head injury protection ...

  7. Night driving simulation in a randomized prospective comparison of Visian toric implantable collamer lens and conventional PRK for moderate to high myopic astigmatism.

    PubMed

    Schallhorn, Steven; Tanzer, David; Sanders, Donald R; Sanders, Monica; Brown, Mitch; Kaupp, Sandor E

    2010-05-01

    To compare changes in simulated night driving performance after Visian Toric Implantable Collamer Lens (TICL; STAAR Surgical) implantation and photorefractive keratectomy (PRK) for the correction of moderate to high myopic astigmatism. This prospective, randomized study consisted of 43 eyes implanted with the TICL (20 bilateral cases) and 45 eyes receiving conventional PRK (VISX Star S3 excimer laser) with mitomycin C (22 bilateral cases) for moderate to high myopia (-6.00 to -20.00 diopters[D] sphere) measured at the spectacle plane and 1.00 to 4.00 D of astigmatism. As a substudy, 27 eyes of 14 TICL patients and 41 eyes of 21 PRK patients underwent a simulated night driving test. The detection and identification distances of road signs and hazards with the Night Driving Simulator (Vision Sciences Research Corp) were measured with and without a glare source before and 6 months after each procedure. No significant difference was noted in the pre- to postoperative Night Driving Simulator in detection distances with and without the glare source between the TICL and PRK groups. The differences in identification distances without glare were significantly better for business and traffic road signs and pedestrian hazards in the TICL group relative to the PRK group whereas with glare, only the pedestrian hazards were significantly better. A clinically relevant change of Night Driving Simulator performance (>0.5 seconds change in ability to identify tasks postoperatively) was significantly better in the TICL group (with and without glare) for all identification tasks. The TICL performed better than conventional PRK in the pre- to postoperative Night Driving Simulator testing with and without a glare source present. Copyright 2010, SLACK Incorporated.

  8. Incidence of rainbow glare after laser in situ keratomileusis flap creation with a 60 kHz femtosecond laser.

    PubMed

    Bamba, Sonya; Rocha, Karolinne M; Ramos-Esteban, Jerome C; Krueger, Ronald R

    2009-06-01

    To report the incidence of and factors associated with rainbow glare after laser in situ keratomileusis (LASIK) flap creation with a 60 kHz femtosecond laser. Department of Refractive Surgery, Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA. Consecutive patients having LASIK by the same surgeon were questioned during postoperative examinations or by telephone about postoperative rainbow glare (radiating colors around a white light at night). Femtosecond laser (IntraLase) settings included pulse frequency 60 kHz, flap thickness 90 to 110 mum, and spot/line separation 8 mum. Raster energy was 0.8 microJ (75% of eyes) and 1.0 to 1.1 microJ (25%). Excimer laser ablation was performed with the LADAR 4000 or 6000 platform using custom or conventional treatments. Of 260 consecutive patients, 256 (98.5%) were successfully contacted. Fifteen patients (28 eyes) reported postoperative rainbow glare (5.8%), described as 4 to 12 bands of color around a white light, with 6 bands most common. The symptom did not correlate with refractive error, age, or sex but was more frequent at 1.0 microJ or 1.1 microJ raster energy (11.6%) than at 0.8 microJ (4.1%). The incidence followed a bimodal distribution, with the first grouping due to inadequate alignment and higher energy just after laser installation and the second just before a later maintenance service call. Rainbow glare is a mild optical side effect of femtosecond LASIK. In this study, higher raster energy levels and length of time between service calls were associated with the occurrence of rainbow glare.

  9. Mobile computing device configured to compute irradiance, glint, and glare of the sun

    DOEpatents

    Gupta, Vipin P; Ho, Clifford K; Khalsa, Siri Sahib

    2014-03-11

    Described herein are technologies pertaining to computing the solar irradiance distribution on a surface of a receiver in a concentrating solar power system or glint/glare emitted from a reflective entity. A mobile computing device includes at least one camera that captures images of the Sun and the entity of interest, wherein the images have pluralities of pixels having respective pluralities of intensity values. Based upon the intensity values of the pixels in the respective images, the solar irradiance distribution on the surface of the entity or glint/glare corresponding to the entity is computed by the mobile computing device.

  10. Solar Glaze Hazard Analysis Tool v. 3.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Clifford K.; Sims, Cianan A.

    SGHAT predicts the occurrence and intensity of glare caused by a user-specified solar panel array when viewed from one or more observation points. An interactive mapping interface is used to determine the latitude, longitude and elevation of the array and observation points. The presence and intensity of glare is then calculated along a given time interval throughout the year, based on the position of the sun. The potential ocular hazard is also reported. The maximum energy production of the solar array is also estimated so that alternative designs can be compared to determine the design that yields the most energymore » production while mitigating glare.« less

  11. Assessment of headlamp glare and potential countermeasures : the effects of headlamp mounting height

    DOT National Transportation Integrated Search

    2008-01-01

    This project examined the effects of headlamp mounting height on the disability and the sensation of discomfort caused by glare. This was performed through a field study and a simulation study. In the field study, subjects evaluated the degree of gla...

  12. Attenuating Photostress and Glare Disability in Pseudophakic Patients through the Addition of a Short-Wave Absorbing Filter.

    PubMed

    Hammond, Billy R

    2015-01-01

    To evaluate the effects of filtering short wavelength light on visual performance under intense light conditions among pseudophakic patients previously implanted with a clear intraocular lens (IOL). This was a patient-masked, randomized crossover study conducted at 6 clinical sites in the United States between September 2013 and January 2014. One hundred fifty-four bilaterally pseudophakic patients were recruited. Photostress recovery time and glare disability thresholds were measured with clip-on blue-light-filtering and placebo (clear; no blue-light filtration) glasses worn over patients' habitual correction. Photostress recovery time was quantified as the time necessary to regain sight of a grating target after intense light exposure. Glare disability threshold was assessed as the intensity of a white-light annulus necessary to obscure a central target. The order of filter used and test eye were randomized across patients. Photostress recovery time and glare disability thresholds were significantly improved (both P < 0.0001) when patients used blue-light-filtering glasses compared with clear, nonfiltering glasses. Compared with a nonfiltering placebo, adding a clip-on blue-absorbing filter to the glasses of pseudophakic patients implanted with clear IOLs significantly increased their ability to cope with glare and to recover normal viewing after an intensive photostress. This result implies that IOL designs with blue-light-filtering characteristics may be beneficial under intense light conditions.

  13. Development of an NCHRP report 350 TL-3 New Jersey shape 50-inch portable concrete barrier : final report, June 2006.

    DOT National Transportation Integrated Search

    2006-06-01

    For roadside work-zones in areas that have opposing traffic flow, safety is enhanced if the temporary barriers incorporate a "glare-shield" that blocks headlight glare from opposing traffic. Currently-available 32-inch portable concrete barriers requ...

  14. Scalability in Production System Programs

    DTIC Science & Technology

    1994-01-01

    met this tall, stooping, mostly bald man who glared at me through large glasses . I guess I must have liked being glared at because within a few days, he...yes) < ceill >) {(cell Aid <id> ^modified no) <cell2>) (modify <celll> ^modified no) (remove <ce12>)) (p stage-computation-O (flag compaite-cells

  15. Evaluation of Workpiece Temperature during Drilling of GLARE Fiber Metal Laminates Using Infrared Techniques: Effect of Cutting Parameters, Fiber Orientation and Spray Mist Application.

    PubMed

    Giasin, Khaled; Ayvar-Soberanis, Sabino

    2016-07-28

    The rise in cutting temperatures during the machining process can influence the final quality of the machined part. The impact of cutting temperatures is more critical when machining composite-metal stacks and fiber metal laminates due to the stacking nature of those hybrids which subjects the composite to heat from direct contact with metallic part of the stack and the evacuated hot chips. In this paper, the workpiece surface temperature of two grades of fiber metal laminates commercially know as GLARE is investigated. An experimental study was carried out using thermocouples and infrared thermography to determine the emissivity of the upper, lower and side surfaces of GLARE laminates. In addition, infrared thermography was used to determine the maximum temperature of the bottom surface of machined holes during drilling GLARE under dry and minimum quantity lubrication (MQL) cooling conditions under different cutting parameters. The results showed that during the machining process, the workpiece surface temperature increased with the increase in feed rate and fiber orientation influenced the developed temperature in the laminate.

  16. Evaluation of Workpiece Temperature during Drilling of GLARE Fiber Metal Laminates Using Infrared Techniques: Effect of Cutting Parameters, Fiber Orientation and Spray Mist Application

    PubMed Central

    Giasin, Khaled; Ayvar-Soberanis, Sabino

    2016-01-01

    The rise in cutting temperatures during the machining process can influence the final quality of the machined part. The impact of cutting temperatures is more critical when machining composite-metal stacks and fiber metal laminates due to the stacking nature of those hybrids which subjects the composite to heat from direct contact with metallic part of the stack and the evacuated hot chips. In this paper, the workpiece surface temperature of two grades of fiber metal laminates commercially know as GLARE is investigated. An experimental study was carried out using thermocouples and infrared thermography to determine the emissivity of the upper, lower and side surfaces of GLARE laminates. In addition, infrared thermography was used to determine the maximum temperature of the bottom surface of machined holes during drilling GLARE under dry and minimum quantity lubrication (MQL) cooling conditions under different cutting parameters. The results showed that during the machining process, the workpiece surface temperature increased with the increase in feed rate and fiber orientation influenced the developed temperature in the laminate. PMID:28773757

  17. Detection and Evaluation of Pre-Preg Gaps and Overlaps in Glare Laminates

    NASA Astrophysics Data System (ADS)

    Nardi, Davide; Abouhamzeh, Morteza; Leonard, Rob; Sinke, Jos

    2018-03-01

    Gaps and overlaps between pre-preg plies represent common flaws in composite materials that can be introduced easily in an automated fibre placement manufacturing process and are potentially detrimental for the mechanical performances of the final laminates. Whereas gaps and overlaps have been addressed for full composite material, the topic has not been extended to a hybrid composite material such as Glare, a member of the family of Fibre Metal Laminates (FMLs). In this paper/research, the manufacturing, the detection, and the optical evaluation of intraply gaps and overlaps in Glare laminates are investigated. As part of an initial assessment study on the effect of gaps and overlaps on Glare, only the most critical lay-up has been considered. The experimental investigation started with the manufacturing of specimens having gaps and overlaps with different widths, followed by a non-destructive ultrasonic-inspection. An optical evaluation of the gaps and overlaps was performed by means of microscope image analysis of the cross sections of the specimens. The results from the non-destructive evaluations show the effectiveness of the ultrasonic detection of gaps and overlaps both in position, shape, width, and severity. The optical inspections confirm the accuracy of the non-destructive evaluation also adding useful insights about the geometrical features due to the presence of gaps and overlaps in the final Glare laminates. All the results justify the need for a further investigation on the effect of gaps and overlaps on the mechanical properties.

  18. Image quality degradation by light-scattering processes in high-performance display devices for medical imaging

    NASA Astrophysics Data System (ADS)

    Badano, Aldo

    1999-11-01

    This thesis addresses the characterization of light scattering processes that degrade image quality in high performance electronic display devices for digital radiography. Using novel experimental and computational tools, we study the lateral diffusion of light in emissive display devices that causes extensive veiling glare and significant reduction of the physical contrast. In addition, we examine the deleterious effects of ambient light reflections that affect the contrast of low luminance regions, and superimpose unwanted structured signal. The analysis begins by introducing the performance limitations of the human visual system to define high fidelity requirements. It is noted that current devices severely suffer from image quality degradation due to optical transport processes. To model the veiling glare and reflectance characteristics of display devices, we introduce a Monte Carlo light transport simulation code, DETECT-II, that tracks individual photons through multiple scattering events. The simulation accounts for the photon polarization state at each scattering event, and provides descriptions for rough surfaces and thin film coatings. A new experimental method to measure veiling glare is described next, based on a conic collimated probe that minimizes contamination from bright areas. The measured veiling glare ratio is taken to be the luminance in the surrounding bright field divided by the luminance in the dark circle. We show that veiling glare ratios in the order of a few hundreds can be measured with an uncertainty of a few percent. The veiling glare response function is obtained by measuring the small spot contrast ratio of test patterns having varying dark spot radius. Using DETECT-II, we then estimate the ring response functions for a high performance medical imaging monitor of current design, and compare the predictions of the model with the experimentally measured response function. The data presented in this thesis demonstrate that although absorption in the faceplate of high performance monochrome cathode-ray tube monitors have reduced glare, a black matrix design is needed for high fidelity applications. For a high performance medical imaging monitor with anti-reflective coating, the glare ratio for a 1 cm diameter dark spot was measured to be 240. Finally, we introduce experimental techniques for measurements of specular and diffuse display reflectance, and we compare measured reflection coefficients with Monte Carlo estimates. A specular reflection coefficient of 0.0012, and a diffuse coefficient of 0.005 nits/lux are required to minimize degradation from ambient light in rooms with 100 lux illumination. In spite of having comparable reflection coefficients, the low maximum luminance of current devices worsens the effect of ambient light reflections when compared to radiographic film. Flat panel technologies with optimized designs can perform even better than film due to a thin faceplate, increased light absorption, and high brightness.

  19. A Recommended Engineering Application of the Method for Evaluating the Visual Significance of Reflected Glare.

    ERIC Educational Resources Information Center

    Blackwell, H. Richard

    1963-01-01

    An application method for evaluating the visual significance of reflected glare is described, based upon a number of decisions with respect to the relative importance of various aspects of visual performance. A standardized procedure for evaluating the overall effectiveness of lighting from photometric data on materials or installations is needed…

  20. Visual acuity from far to near and contrast sensitivity in eyes with a diffractive multifocal intraocular lens with a low addition power.

    PubMed

    Hayashi, Ken; Manabe, Shin-Ichi; Hayashi, Hideyuki

    2009-12-01

    To compare visual acuity from far to near, contrast visual acuity, and acuity in the presence of glare (glare visual acuity) between an aspheric diffractive multifocal intraocular lens (IOL) with a low addition (add) power (+3.0 diopters) and a monofocal IOL. Hayashi Eye Hospital, Fukuoka, Japan. This prospective study comprised patients having implantation of an aspheric diffractive multifocal ReSTOR SN6AD1 IOL with a +3.0 D add (multifocal group) or a monofocal AcrySof IQ SN60WF IOL (monofocal group). Visual acuity from far to near distances, contrast acuity, and glare acuity were evaluated 3 months postoperatively. Each IOL group comprised 64 eyes of 32 patients. For monocular and binocular visual acuity, the mean uncorrected and distance-corrected intermediate acuity at 0.5 m and the near acuity at 0.3 m were significantly better in the multifocal group than in the monofocal group (P

  1. Google Glass Glare: disability glare produced by a head-mounted visual display.

    PubMed

    Longley, Chris; Whitaker, David

    2016-03-01

    Head mounted displays are a type of wearable technology - a market that is projected to expand rapidly over the coming years. Probably the most well known example is the device Google Glass (or 'Glass'). Here we investigate the extent to which the device display can interfere with normal visual function by producing monocular disability glare. Contrast sensitivity was measured in two normally sighted participants, 32 and 52 years of age. Data were recorded for the right eye, the left eye and then again in a binocular condition. Measurements were taken both with and without the Glass in place, across a range of stimulus luminance levels using a two-alternative forced-choice methodology. The device produced a significant reduction in contrast sensitivity in the right eye (>0.5 log units). The level of disability glare increased as stimulus luminance was reduced in a manner consistent with intraocular light scatter, resulting in a veiling retinal illuminance. Sensitivity in the left eye was unaffected. A significant reduction in binocular contrast sensitivity occurred at lower luminance levels due to a loss of binocular summation, although binocular sensitivity was not found to fall below the sensitivity of the better monocular level (binocular inhibition). Head mounted displays such as Google Glass have the potential to cause significant disability glare in the eye exposed to the visual display, particularly under conditions of low luminance. They can also cause a more modest binocular reduction in sensitivity by eliminating the benefits of binocular summation. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  2. Study on acute toxicity of anti-vertigo granule on mice

    NASA Astrophysics Data System (ADS)

    Wen, Zhonghua; Hao, Shaojun; Xie, Guoqi; Li, Jun; Su, Feng; Liu, Xiaobin; Wang, Xidong; Zhang, Zhengchen

    2018-04-01

    To observe the effect of anti - glare particles on acute toxicity of mice. Methods: 40 male and female mice weighing 18 - 21 g were randomly divided into anti - glare granule group and normal saline control group. The maximum volume of anti - glare particles (0.94 g/ml) was administered before the experiment. Results: the oral toxicity of the suspension was very small. The maximal concentration of mice was given at the maximum volume of gastric perfusion, and it was given three times in 1st. The cumulative maximum tolerance dose was 112.8g/kg per day. The dose was 226 times of clinical dosage and no death was found in mice. Conclusion: the toxicity of Kangxuan granules is very small and it can be considered safe in clinical use.

  3. Practical Application of Polarization and Light Control for Reduction of Reflected Glare.

    ERIC Educational Resources Information Center

    Crouch, C. L.; Kaufman, J. E.

    1963-01-01

    The role of reflected glare and visual viewing angles in near task performance is discussed, and following statements are reported--(1) a worker at a desk normally assumes a position in which his eyes traverse an area of work extending from a point approximately vertically below his eyes to a point not more than 40 degrees from the vertical, (2) a…

  4. Comparison of visual function between phakic eyes and pseudophakic eyes with a monofocal intraocular lens.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-ichi; Hayashi, Hideyuki

    2010-01-01

    To compare all-distance visual acuity and contrast visual acuity with and without glare (glare visual acuity) between phakic eyes with a clear lens and pseudophakic eyes with a monofocal intraocular lens. Hayashi Eye Hospital, Fukuoka, Japan. This study comprised phakic), pseudophakic eyes in 4 age groups (40s, 50s, 60s, 70s). Corrected visual acuity from far to near, contrast visual acuity, and glare visual acuity were examined. The mean corrected intermediate and near visual acuities were significantly better in phakic eyes than in pseudophakic eyes in patients in their 40s and 50s (P

  5. Will musculoskeletal and visual stress change when Visual Display Unit (VDU) operators move from small offices to an ergonomically optimized office landscape?

    PubMed

    Helland, Magne; Horgen, Gunnar; Kvikstad, Tor Martin; Garthus, Tore; Aarås, Arne

    2011-11-01

    This study investigated the effect of moving from small offices to a landscape environment for 19 Visual Display Unit (VDU) operators at Alcatel Denmark AS. The operators reported significantly improved lighting condition and glare situation. Further, visual discomfort was also significantly reduced on a Visual Analogue Scale (VAS). There was no significant correlation between lighting condition and visual discomfort neither in the small offices nor in the office landscape. However, visual discomfort correlated significantly with glare in small offices i.e. more glare is related to more visual discomfort. This correlation disappeared after the lighting system in the office landscape had been improved. There was also a significant correlation between glare and itching of the eyes as well as blurred vision in the small offices, i.e. more glare more visual symptoms. Experience of pain was found to reduce the subjective assessment of work capacity during VDU tasks. There was a significant correlation between visual discomfort and reduced work capacity in small offices and in the office landscape. When moving from the small offices to the office landscape, there was a significant reduction in headache as well as back pain. No significant changes in pain intensity in the neck, shoulder, forearm, and wrist/hand were observed. The pain levels in different body areas were significantly correlated with subjective assessment of reduced work capacity in small offices and in the office landscape. By careful design and construction of an office landscape with regard to lighting and visual conditions, transfer from small offices may be acceptable from a visual-ergonomic point of view. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  6. Integration of non-Lambertian LED and reflective optical element as efficient street lamp.

    PubMed

    Pan, Jui-Wen; Tu, Sheng-Han; Sun, Wen-Shing; Wang, Chih-Ming; Chang, Jenq-Yang

    2010-06-21

    A cost effective, high throughput, and high yield method for the increase of street lamp potency was proposed in this paper. We integrated the imprinting technology and the reflective optical element to obtain a street lamp with high illumination efficiency and without glare effect. The imprinting technique can increase the light extraction efficiency and modulate the intensity distribution in the chip level. The non-Lambertian light source was achieved by using imprinting technique. The compact reflective optical element was added to efficiently suppress the emitting light intensity with small emitting angle for the uniform of illumination intensity and excluded the light with high emitting angle for the prevention of glare. Compared to the conventional street lamp, the novel design has 40% enhancement in illumination intensity, the uniform illumination and the glare effect elimination.

  7. Investigation into the Fiber Orientation Effect on the Formability of GLARE Materials in the Stamp Forming Process

    NASA Astrophysics Data System (ADS)

    Liu, Shichen; Lang, Lihui; Sherkatghanad, Ehsan; Wang, Yao; Xu, Wencai

    2018-04-01

    Glass-reinforced aluminum laminate (GLARE) is a new class of fiber metal laminates (FMLs) which has the advantages such as high tensile strength, outstanding fatigue, impact resistance, and excellent corrosion properties. GLARE has been extensively applied in advanced aerospace and automobile industries. However, the deformation behavior of the glass fiber during forming must be studied to the benefits of the good-quality part we form. In this research, we focus on the effect of fiber layer orientation on the GLARE laminate formability in stamp forming process. Experimental and numerical analysis of stamping a hemisphere part in different fiber orientation is investigated. The results indicate that unidirectional and multi-directional fiber in the middle layer make a significant effect on the thinning and also surface forming quality of the three layer sheet. Furthermore, the stress-strain distribution of the aluminum alloy and the unique anisotropic property of the fiber layer exhibit that fiber layer orientation can also affect the forming depths as well as the fracture modes of the laminate. According to the obtained results, it is revealed that multi-directional fiber layers are a good alternative compared to the unidirectional fibers especially when a better formability is the purpose.

  8. Night Vision Manual for the Flight Surgeon.

    DTIC Science & Technology

    1985-08-01

    by optic nerve and pathways to Brodmann’s occipital areas 17 and 18). Perception occurs - vision Sensitive material ( retinal pigment) must be...clearly may be defined as glare. Glare becomes a problem in patients with opacities of the ocular media or with retinal diseases. 3 FME tN [I.I Sl IN FM...reduction of pupillary area caused by the drug. 3. Retinal causes of abnormal dark adaptation. a. Congenital stationary night blindness. b. etinitis

  9. Validation of the Five-Phase Method for Simulating Complex Fenestration Systems with Radiance against Field Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geisler-Moroder, David; Lee, Eleanor S.; Ward, Gregory J.

    2016-08-29

    The Five-Phase Method (5-pm) for simulating complex fenestration systems with Radiance is validated against field measurements. The capability of the method to predict workplane illuminances, vertical sensor illuminances, and glare indices derived from captured and rendered high dynamic range (HDR) images is investigated. To be able to accurately represent the direct sun part of the daylight not only in sensor point simulations, but also in renderings of interior scenes, the 5-pm calculation procedure was extended. The validation shows that the 5-pm is superior to the Three-Phase Method for predicting horizontal and vertical illuminance sensor values as well as glare indicesmore » derived from rendered images. Even with input data from global and diffuse horizontal irradiance measurements only, daylight glare probability (DGP) values can be predicted within 10% error of measured values for most situations.« less

  10. Fracture and strain rate behavior of airplane fuselage materials under blast loading

    NASA Astrophysics Data System (ADS)

    Mediavilla Varas, J.; Soetens, F.; Kroon, E.; van Aanhold, J. E.; van der Meulen, O. R.; Sagimon, M.

    2010-06-01

    The dynamic behavior of three commonly used airplane fuselage materials is investigated, namely of Al2024-T3, Glare-3 and CFRP. Dynamic tensile tests using a servo-hydraulic and a light weight shock testing machine (LSM) have been performed. The results showed no strain rate effect on Al2024-T3 and an increase in the failure strain and failure strength of Glare-3, but no stiffening. The LSM results on CFRP were inconclusive. Two types of fracture tests were carried out to determine the dynamic crack propagation behavior of these materials, using prestressed plates and pressurized barrels, both with the help of explosives. The prestressed plates proved to be not suitable, whereas the barrel tests were quite reliable, allowing to measure the crack speeds. The tougher, more ductile materials, Al2024-T3 and Glare-3, showed lower crack speeds than CFRP, which failed in a brittle manner.

  11. Evaluation of OLED and edge-lit LED lighting panels

    NASA Astrophysics Data System (ADS)

    Mou, Xi; Narendran, Nadarajah; Zhu, Yiting; Freyssinier, Jean Paul

    2016-09-01

    Solid-state lighting (SSL) offers a new technology platform for lighting designers and end-users to illuminate spaces with low energy demand. Two types of SSL sources include organic light-emitting diodes (OLEDs) and light-emitting diodes (LEDs). OLED is an area light source, and its primary competing technology is the edge-lit LED panel. Generally, both of these technologies are considered similar in shape and appearance, but there is little understanding of how people perceive discomfort glare from large area light sources. The objective of this study was to evaluate discomfort glare for the two lighting technologies under similar operating conditions by gathering observers' reactions. The human factors study results showed no statistically significant difference in human response to discomfort glare between OLED and edge-lit LED panels when the two light sources produced the same lighting stimulus. This means both technologies appeared equally glary beyond a certain luminance.

  12. The effect of variably tinted spectacle lenses on visual performance in cataract subjects.

    PubMed

    Naidu, Srilata; Lee, Jason E; Holopigian, Karen; Seiple, William H; Greenstein, Vivienne C; Stenson, Susan M

    2003-01-01

    A body of clinical and laboratory evidence suggests that tinted spectacle lenses may have an effect on visual performance. The aim of this study was to quantify the effects of spectacle lens tint on the visual performance of 25 subjects with cataracts. Cataracts were scored based on best-corrected acuity and by comparison with the Lens Opacity Classification System (LOCS III) plates. Visual performance was assessed by measuring contrast sensitivity with and without glare (Morphonome software version 4.0). The effect of gray, brown, yellow, green and purple tinting was evaluated. All subjects demonstrated an increase in contrast thresholds under glare conditions regardless of lens tint. However, brown and yellow lens tints resulted in the least amount of contrast threshold increase. Gray lens tint resulted in the largest contrast threshold increase. Individuals with lenticular changes may benefit from brown or yellow spectacle lenses under glare conditions.

  13. From bed topography to ice thickness: GlaRe, a GIS tool to reconstruct the surface of palaeoglaciers

    NASA Astrophysics Data System (ADS)

    Pellitero, Ramon; Rea, Brice; Spagnolo, Matteo; Bakke, Jostein; Ivy-Ochs, Susan; Frew, Craig; Hughes, Philip; Ribolini, Adriano; Renssen, Hans; Lukas, Sven

    2016-04-01

    We present GlaRe, A GIS tool that automatically reconstructs the 3D geometry for palaeoglaciers given the bed topography. This tool utilises a numerical approach and can work using a minimum of morphological evidence i.e. the position of the palaeoglacier front. The numerical approach is based on an iterative solution to the perfect plasticity assumption for ice rheology, explained in Benn and Hulton (2010). The tool can be run in ArcGIS 10.1 (ArcInfo license) and later updates and the toolset is written in Python code. The GlaRe toolbox presented in this paper implements a well-established approach for the determination of palaeoglacier equilibrium profiles. Significantly it permits users to quickly run multiple glacier reconstructions which were previously very laborious and time consuming (typically days for a single valley glacier). The implementation of GlaRe will facilitate the reconstruction of large numbers of palaeoglaciers which will provide opportunities for such research addressing at least two fundamental problems: 1. Investigation of the dynamics of palaeoglaciers. Glacier reconstructions are often based on a rigorous interpretation of glacial landforms but not always sufficient attention and/or time has been given to the actual reconstruction of the glacier surface, which is crucial for the calculation of palaeoglacier ELAs and subsequent derivation of quantitative palaeoclimatic data. 2. the ability to run large numbers of reconstructions and over much larger spatial areas provides an opportunity to undertake palaeoglaciers reconstructions across entire mountain, ranges, regions or even continents, allowing climatic gradients and atmospheric circulation patterns to be elucidated. The tool performance has been evaluated by comparing two extant glaciers, an icefield and a cirque/valley glacier from which the subglacial topography is known with a basic reconstruction using GlaRe. Results from the comparisons between extant glacier surfaces and modelled ones show very similar ELA values on the order of 10-20 meter error (which would account for a 0.065-0.13 K degree variation on a typical -6.5 K altitudinal gradient), and these can be improved further by increasing the number of flowlines and using F factors where needed. GlaRe is able to quickly generate robust palaeoglacier surfaces based on the very limited inputs often available from the geomorphological record.

  14. Airborne Data Link Operational Evaluation Test Plan

    DTIC Science & Technology

    1993-08-01

    be provided by a combination of glare shield mounted, blue lens , aviation-type lamps and lighted distinctive message indicators on the CDUs or CDU...consist of either SELCAL sound only or SELCAL tone combined with forward primary field of view visual alerting (a blue light mounted on the glare shield in...INCORPORATED DOT/FAA/CT-TN93/30 9. Pe’form,"g Orgaoniatio Name end Address 10. Work Unit No. (TRAIS) CTA, INCORPORATED Suite 1000 11 Contac of Great me. 2500

  15. Comparison of glare in YAG-damaged intraocular lenses: injection-molded versus lathe-cut.

    PubMed

    Bath, P E; Dang, Y; Martin, W H

    1986-11-01

    A comparative analysis of YAG laser intraocular lens (IOL) damage was undertaken on injection-molded and lathe-cut IOLs. Damage sites were evaluated with polarized light. A consistent positive polarization was observed in the damage sites of lathe-cut IOLs. A consistent negative polarization was observed in the damage sites of injection-molded IOLs. The presence of positive polarization in IOL damage sites may be correlated with increased potential for glare. Results and clinical implications are discussed.

  16. The influence of ambient light on the driver

    NASA Astrophysics Data System (ADS)

    Klinger, Karsten D.; Lemmer, Uli

    2008-04-01

    Increasingly, cars are fitted with interior ambient lighting which is switched on while driving. This special kind of interior light emphasizes the interior design of the car, it makes a car look special and gives the buyers a new option to personalize their automobiles. But how does ambient interior light influence the driver? We conducted a series of over 50 tests to study the influence of interior ambient light on contrast perception under different illumination levels, colors and positions of the illuminated areas. Our tests show that in many cases the ambient lighting can improve the visual contrast for seeing objects in the headlamp beam. But the test persons mentioned that the tested brightness looked too bright and that they felt glared. The measured values instead proved that no disability glare exists. Therefore, provided that the drivers can adjust the intensity of the ambient light to avoid glare, the ambient light has no negative effect on the drivers' contrast perception.

  17. Thermal and optical design analyses, optimizations, and experimental verification for a novel glare-free LED lamp for household applications.

    PubMed

    Khan, M Nisa

    2015-07-20

    Light-emitting diode (LED) technologies are undergoing very fast developments to enable household lamp products with improved energy efficiency and lighting properties at lower cost. Although many LED replacement lamps are claimed to provide similar or better lighting quality at lower electrical wattage compared with general-purpose incumbent lamps, certain lighting characteristics important to human vision are neglected in this comparison, which include glare-free illumination and omnidirectional or sufficiently broad light distribution with adequate homogeneity. In this paper, we comprehensively investigate the thermal and lighting performance and trade-offs for several commercial LED replacement lamps for the most popular Edison incandescent bulb. We present simulations and analyses for thermal and optical performance trade-offs for various LED lamps at the chip and module granularity levels. In addition, we present a novel, glare-free, and production-friendly LED lamp design optimized to produce very desirable light distribution properties as demonstrated by our simulation results, some of which are verified by experiments.

  18. Results in Combined Cataract Surgery With Prosthetic Iris Implantation in Patients With Previous Iridocyclectomy for Iris Melanoma.

    PubMed

    Snyder, Michael E; Osher, Robert H; Wladecki, Trisha M; Perez, Mauricio A; Augsburger, James J; Corrêa, Zélia

    2017-03-01

    To present visual and functional results following implantation of iris prosthesis combined with cataract surgery in eyes with previous iridocyclectomy for iris melanoma or presumed iris melanoma. Retrospective noncomparative case series. Sixteen patients (16 eyes) with iris defects after iridocyclectomy for iris melanoma in 15 cases and iris adenoma in 1 case underwent prosthetic iris device implantation surgery. Prosthetic iris implantation was combined with phacoemulsification and intraocular lens (IOL) implantation. The visual acuity, subjective glare and photophobia reduction, anatomic outcome, and complications were reviewed. Best-corrected visual acuity was improved in 13 eyes (81.25%), remained stable in 2 eyes (12.25%), and decreased in 1 eye (6.25%). Photophobia and glare improved in every case except for 1 (93.75%). Notably, after surgery 12 patients (75.00%) reported no photophobia and 10 patients (62.50%) reported no glare. The median postoperative follow-up was 29.5 months, with a minimum of 5 months and a maximum of 189 months. All iris devices were in the correct position, and all eyes achieved the desired anatomic result. The IOL optic edges were covered in all areas by either residual iris or opaque portions of a prosthetic iris device. In patients who have undergone previous iridocyclectomy for presumed iris melanoma, combined cataract surgery and iris prosthesis placement, with or without iris reconstruction, can lead to visual improvement as well as reduction of both glare and photophobia. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Effect of Yellow-Tinted Lenses on Visual Attributes Related to Sports Activities

    PubMed Central

    Kohmura, Yoshimitsu; Murakami, Shigeki; Aoki, Kazuhiro

    2013-01-01

    The purpose of this study was to clarify the effect of colored lenses on visual attributes related to sports activities. The subjects were 24 students (11 females, 13 males; average age 21.0 ±1.2 years) attending a sports university. Lenses of 5 colors were used: colorless, light yellow, dark yellow, light gray, and dark gray. For each lens, measurements were performed in a fixed order: contrast sensitivity, dynamic visual acuity, depth perception, hand-eye coordination and visual acuity and low-contrast visual acuity. The conditions for the measurements of visual acuity and low-contrast visual acuity were in the order of Evening, Evening+Glare, Day, and Day+Glare. There were no significant differences among lenses in dynamic visual acuity and depth perception. For hand-eye coordination, time was significantly shorter with colorless than dark gray lenses. Contrast sensitivity was significantly higher with colorless, light yellow, and light gray lenses than with dark yellow and dark gray lenses. The low-contrast visual acuity test in the Day+Glare condition showed no significant difference among the lenses. In the Evening condition, low-contrast visual acuity was significantly higher with colorless and light yellow lenses than with dark gray lenses, and in the Evening+Glare condition, low-contrast visual acuity was significantly higher with colorless lenses than with the other colors except light yellow. Under early evening conditions and during sports activities, light yellow lenses do not appear to have an adverse effect on visual attributes. PMID:23717352

  20. Optical side-effects of fs-laser treatment in refractive surgery investigated by means of a model eye

    PubMed Central

    Ackermann, Roland; Kammel, Robert; Merker, Marina; Kamm, Andreas; Tünnermann, Andreas; Nolte, Stefan

    2013-01-01

    Optical side-effects of fs-laser treatment in refractive surgery are investigated by means of a model eye. We show that rainbow glare is the predominant perturbation, which can be avoided by randomly distributing laser spots within the lens. For corneal applications such as fs-LASIK, even a regular grid with spot-to-spot distances of ~3 µm is sufficient to minimize rainbow glare perception. Contrast sensitivity is affected, when the lens is treated with large 3D-patterns. PMID:23413236

  1. A comprehensive assessment of visual impairment in a population of older Americans. The SEE Study. Salisbury Eye Evaluation Project.

    PubMed

    Rubin, G S; West, S K; Muñoz, B; Bandeen-Roche, K; Zeger, S; Schein, O; Fried, L P

    1997-03-01

    The Salisbury Eye Evaluation Project is a longitudinal study of risk factors for age-related eye diseases and the impact of eye disease and visual impairment on physical disability. In this article, the authors report the prevalence of visual impairment in their population and explore the relations among the various measures of visual function. A population-based sample of 2520 residents of Salisbury, Maryland, between the ages of 65 and 84 years were enrolled in the study. Twenty-six percent of participants were black. Vision tests included best-corrected Early Treatment Diabetic Retinopathy Study acuity, Pelli-Robson contrast sensitivity with and without glare, Randot stereoacuity, and 60 degrees Humphrey visual fields. Visual function decreased linearly with age for the acuity, contrast sensitivity, glare, and visual field tests. Stereoacuity remained constant into the mid-70s and declined at an accelerating rate thereafter. Black participants had lower contrast sensitivity, reduced stereoacuity, and worse visual fields, at all ages compared to white participants; however, white participants were more sensitive to glare. The overall prevalence of visual acuity impairment in blacks was 5.6% versus 3.0% for whites, using the traditional United States definition (worse than 20/40 to better than 20/200) and 3.3% for blacks versus 1.6% for whites, using the World Health Organization definition (worse than 20/60 to 20/400). Acuity was correlated moderately with contrast sensitivity, stereoacuity, and visual fields (Spearman rho = 0.50, 0.35, and 0.34, respectively). The correlation between acuity and glare sensitivity was low (rho = 0.12). Many aspects of visual function, not just acuity, decline with age. Black participants have more visual impairement than do white participants for all tests except glare sensitivity. The prevalence of visual acuity impairement in the Salisbury Eye Evaluation population is lower than that reported by other studies using similar test procedures. Low-to-moderate correlations among vision test scores suggest that several different dimensions of visual function are being assessed.

  2. Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thanachareonkit, Anothai; Lee, Eleanor S.; McNeil, Andrew

    2013-08-31

    Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Microstructured prismatic window films can be manufactured using low-cost, roll-to-roll fabrication methods and adhered to the inside surface of existing windows as a retrofit measure or installed as a replacement insulating glass unit in the clerestory portion of the window wall. A clear film patterned with linear, 50-250 micrometer high, four-sided asymmetrical prisms was fabricated and installed in the south-facing, clerestory low-e, clear glazed windows of a full-scale testbed facility. Views through the film were distorted. The film was evaluated in amore » sunny climate over a two-year period to gauge daylighting and visual comfort performance. The daylighting aperture was small (window-towall ratio of 0.18) and the lower windows were blocked off to isolate the evaluation to the window film. Workplane illuminance measurements were made in the 4.6 m (15 ft) deep room furnished as a private office. Analysis of discomfort glare was conducted using high dynamic range imaging coupled with the evalglare software tool, which computes the daylight glare probability and other metrics used to evaluate visual discomfort. The window film was found to result in perceptible levels of discomfort glare on clear sunny days from the most conservative view point in the rear of the room looking toward the window. Daylight illuminance levels at the rear of the room were significantly increased above the reference window condition, which was defined as the same glazed clerestory window but with an interior Venetian blind (slat angle set to the cut-off angle), for the equinox to winter solstice period on clear sunny days. For partly cloudy and overcast sky conditions, daylight levels were improved slightly. To reduce glare, the daylighting film was coupled with a diffusing film in an insulating glazing unit. The diffusing film retained the directionality of the redirected light spreading it within a small range of outgoing angles. This solution was found to reduce glare to imperceptible levels while retaining for the most part the illuminance levels achieved solely by the daylighting film.« less

  3. All-distance visual acuity and contrast visual acuity in eyes with a refractive multifocal intraocular lens with minimal added power.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hayashi, Hideyuki

    2009-03-01

    To compare visual acuity (VA) from far to near distances, photopic and mesopic contrast VA, and contrast VA in the presence of a glare source (glare VA), between eyes with a new refractive multifocal intraocular lens (IOL) with added power of only +3.0 diopters and those with a monofocal IOL. Comparative, nonrandomized, interventional study. Forty-four eyes of 22 patients who were scheduled for implantation of a refractive multifocal IOL (Hoya SFX MV1; Tokyo, Japan) and 44 eyes of 22 patients scheduled for implantation of a monofocal IOL. All patients underwent phacoemulsification with bilateral implantation of either multifocal or monofocal IOLs. At approximately 3 months after surgery, monocular and binocular VA from far to near distances was measured using the all-distance vision tester (Kowa AS-15; Tokyo, Japan), whereas photopic and mesopic contrast VA and glare VA were examined using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000, Nagoya, Japan). Pupillary diameter and the degree of IOL decentration and tilt were correlated with VA at all distances. Mean VA in both the multifocal and monofocal IOL groups decreased gradually from far to near distances. When comparing the 2 groups, however, both uncorrected and best distance-corrected intermediate VA at 0.5 m and near VA at 0.3 m in the multifocal IOL group were significantly better than those in the monofocal IOL group (P

  4. Long-term effect of surface light scattering and glistenings of intraocular lenses on visual function.

    PubMed

    Hayashi, Ken; Hirata, Akira; Yoshida, Motoaki; Yoshimura, Koichi; Hayashi, Hideyuki

    2012-08-01

    To investigate the long-term effect of surface light scattering and glistenings of various intraocular lenses (IOLs) on visual function and optical aberrations after cataract surgery. Case-control study. Thirty-five eyes that underwent implantation of a hydrophobic acrylic, silicone, or polymethyl methacrylate (PMMA) IOL more than 10 years ago were recruited. The scattering light intensity of the surface and internal matrix of the optic was measured using Scheimpflug photography. Visual acuity (VA) was measured using VA charts, and contrast VA and that with glare (glare VA) were examined using a contrast sensitivity tester. Ocular higher-order aberrations (HOAs) were measured using a Hartmann-Shack aberrometer. Mean scattering light intensity of the surface and internal matrix of the optic was significantly higher in the acrylic group than in the silicone and PMMA groups (P < .0001). Mean uncorrected VA, photopic and mesopic contrast VA and glare VA, and HOAs did not differ significantly among groups, although mean corrected VA in the acrylic group was significantly better than that in the other groups (P = .0023). Scattering light intensity of the surface and internal matrix did not correlate with VA, contrast VA, or glare VA, and did not correlate with ocular and internal optic HOAs in the acrylic group. At more than 10 years postoperatively, visual function, including contrast sensitivity, and ocular HOAs were comparable among eyes that received acrylic, silicone, and PMMA IOLs. Surface scattering and glistenings with the acrylic IOLs were not significantly correlated with visual function and optical aberrations. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Sunglasses with thick temples and frame constrict temporal visual field.

    PubMed

    Denion, Eric; Dugué, Audrey Emmanuelle; Augy, Sylvain; Coffin-Pichonnet, Sophie; Mouriaux, Frédéric

    2013-12-01

    Our aim was to compare the impact of two types of sunglasses on visual field and glare: one ("thick sunglasses") with a thick plastic frame and wide temples and one ("thin sunglasses") with a thin metal frame and thin temples. Using the Goldmann perimeter, visual field surface areas (cm²) were calculated as projections on a 30-cm virtual cupola. A V4 test object was used, from seen to unseen, in 15 healthy volunteers in the primary position of gaze ("base visual field"), then allowing eye motion ("eye motion visual field") without glasses, then with "thin sunglasses," followed by "thick sunglasses." Visual field surface area differences greater than the 14% reproducibility error of the method and having a p < 0.05 were considered significant. A glare test was done using a surgical lighting system pointed at the eye(s) at different incidence angles. No significant "base visual field" or "eye motion visual field" surface area variations were noted when comparing tests done without glasses and with the "thin sunglasses." In contrast, a 22% "eye motion visual field" surface area decrease (p < 0.001) was noted when comparing tests done without glasses and with "thick sunglasses." This decrease was most severe in the temporal quadrant (-33%; p < 0.001). All subjects reported less lateral glare with the "thick sunglasses" than with the "thin sunglasses" (p < 0.001). The better protection from lateral glare offered by "thick sunglasses" is offset by the much poorer ability to use lateral space exploration; this results in a loss of most, if not all, of the additional visual field gained through eye motion.

  6. Effects of Constituents and Lay-up Configuration on Drop-Weight Tests of Fiber-Metal Laminates

    NASA Astrophysics Data System (ADS)

    Liu, Yanxiong; Liaw, Benjamin

    2010-02-01

    Impact responses and damage of various fiber-metal laminates were studied using a drop-weight instrument with the post-impact damage characteristics being evaluated through ultrasonic and mechanical sectioning techniques. The first severe failure induced by the low-velocity drop-weight impact occurred as delamination between the aluminum and fiber-epoxy layers at the non-impact side. It was followed by a visible shear crack in the outer aluminum layer on the non-impact face. Through-thickness shear cracks in the aluminum sheets and severe damage in the fiber laminated layers (including delamination between adjacent fiber-epoxy laminae with different fiber orientations) developed under higher energy impacts. The impact properties of fiber-metal laminates varied with different constituent materials and fiber orientations. Since it was punched through easily, the aramid-fiber reinforced fiber-metal laminates (ARALL) offered poorer impact resistance than the glass-fiber reinforced fiber-metal laminates (GLARE). Tougher and more ductile aluminum alloys improved the impact resistance. GLARE made of cross-ply prepregs provided better impact resistance than GLARE with unidirectional plies.

  7. Macular pigment levels do not influence C-Quant retinal straylight estimates in young Caucasians.

    PubMed

    Beirne, Raymond O

    2014-03-01

    Individuals with higher than normal levels of macular pigment optical density (MPOD) are less affected by disability glare, when using glare source lights with a strong short-wavelength component. The aim of this study was to investigate whether estimates of retinal straylight from the Oculus Cataract Quantifier (C-Quant), which corresponds to disability glare, are associated with estimates of macular pigment levels in young Caucasian eyes. Thirty-seven Caucasian individuals (aged 19 to 40 years) with good visual acuity, free from ocular disease and with clear ocular media participated. Macular pigment optical density was measured at 0.5 degrees eccentricity from the foveal centre using a heterochromatic flicker photometry-based densitometer instrument from MacularMetrics. Retinal straylight was estimated using the C-Quant, a commercially available device, which uses a psychophysical compensation comparison method. Mean MPOD was 0.39 ± 0.18 log units (range zero to 0.80) and was not significantly related to age (r = -0.07, p = 0.66). Mean straylight parameter (s) was 1.01 ± 0.09 log units (range 0.86 to 1.21) and was not significantly related to age (r = -0.03, p = 0.86). Although there was a small tendency for straylight measurements to be reduced in individuals with higher levels of MPOD, there was no statistically significant relationship between retinal straylight and MPOD (r = -0.17, p = 0.30). Ocular straylight, estimated by the Oculus C-Quant, is little influenced by macular pigment optical density. As the C-Quant uses balanced (white) lights, it is suggested that the previous findings on the effect of macular pigment critically depend on the use of blue-dominant glare sources. © 2013 The Author. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  8. Visual and psychological stress during computer work in healthy, young females-physiological responses.

    PubMed

    Mork, Randi; Falkenberg, Helle K; Fostervold, Knut Inge; Thorud, Hanne Mari S

    2018-05-30

    Among computer workers, visual complaints, and neck pain are highly prevalent. This study explores how occupational simulated stressors during computer work, like glare and psychosocial stress, affect physiological responses in young females with normal vision. The study was a within-subject laboratory experiment with a counterbalanced, repeated design. Forty-three females performed four 10-min computer-work sessions with different stress exposures: (1) minimal stress; (2) visual stress (direct glare); (3) psychological stress; and (4) combined visual and psychological stress. Muscle activity and muscle blood flow in trapezius, muscle blood flow in orbicularis oculi, heart rate, blood pressure, blink rate and postural angles were continuously recorded. Immediately after each computer-work session, fixation disparity was measured and a questionnaire regarding perceived workstation lighting and stress was completed. Exposure to direct glare resulted in increased trapezius muscle blood flow, increased blink rate, and forward bending of the head. Psychological stress induced a transient increase in trapezius muscle activity and a more forward-bent posture. Bending forward towards the computer screen was correlated with higher productivity (reading speed), indicating a concentration or stress response. Forward bent posture was also associated with changes in fixation disparity. Furthermore, during computer work per se, trapezius muscle activity and blood flow, orbicularis oculi muscle blood flow, and heart rate were increased compared to rest. Exposure to glare and psychological stress during computer work were shown to influence the trapezius muscle, posture, and blink rate in young, healthy females with normal binocular vision, but in different ways. Accordingly, both visual and psychological factors must be taken into account when optimizing computer workstations to reduce physiological responses that may cause excessive eyestrain and musculoskeletal load.

  9. Potential energy savings with exterior shades in large office buildings and the impact of discomfort glare

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffmann, Sabine; Lee, Eleanor

    Exterior shades are highly efficient for reducing solar load in commercial buildings. Their impact on net energy use depends on the annual energy balance of heating, cooling, fan and lighting energy. This paper discusses the overall energy use intensity of various external shading systems for a prototypical large office building split into the different types of energy use and for different orientations and window sizes. Lighting energy was calculated for a constant lighting power as well as for dimmed lighting fixtures (daylighting control). In Section 3, slat angles and solar cut-off angles were varied for fixed exterior slat shading systems.more » While the most light-blocking shades performed best for the case without daylighting controls, the optimum cut-off angle with daylighting controls was found to be 30 deg for the office building prototype used in Chicago and Houston. For large window-to-wall (WWR) ratios, window related annual energy use could be reduced by at least 70 % without daylighting control and by a minimum of 86 % with daylighting control in average over all orientations. The occurrence of discomfort glare was is considered in Section 4 of the paper, which looks at the performance of commercially available exterior shading systems when an interior shade is used in addition to the exterior shade during hours when occupants would experience discomfort glare. Glare control impacts overall energy use intensity significantly for exterior shades with high transmittance, especially when daylighting controls are used. In these cases, exterior shades are only beneficial for window-to-wall areas ≥ 45% in the hot Houston climate. For smaller windows and in a heating/cooling climate like Chicago, exterior shades can increase energy consumption« less

  10. Development and experimental verification of an intraocular scattering model

    NASA Astrophysics Data System (ADS)

    Jiang, Chong-Jhih; Jhong, Tian-Siang; Chen, Yi-Chun; Sun, Ching-Cherng

    2011-10-01

    An intraocular scattering model was constructed in human eye model and experimentally verified. According to the biometric data, the volumetric scattering in crystalline lens and diffusion at retina fundus were developed. The scattering parameters of cornea, including particle size and obscuration ratio, were varied to make the veiling luminance of the eye model matching the CIE disability glare general formula. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated and compared with that of transparent lenses. The MTF of the intraocular scattering model showed nice correspondence with the data measured by a double-pass experiment.

  11. Tower Illuminance Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Clifford K.; Sims, Cianan

    TIM is a real-time interactive concentrating solar field simulation. TIM models a concentrating tower (receiver), heliostat field, and potential reflected glare based on user-specified parameters such as field capacity, tower height and location. TIM provides a navigable 3D interface, allowing the user to “fly” around the field to determine the potential glare hazard from off-target heliostats. Various heliostat aiming strategies are available for specifying how heliostats behave when in standby mode. Strategies include annulus, point-per-group, up-aiming and single-point-focus. Additionally, TIM includes an avian path feature for approximating the irradiance and feather temperature of a bird flying through the field airspace.

  12. Light budget and optimization strategies for display applications of dichroic nematic droplet/polymer films

    NASA Astrophysics Data System (ADS)

    Drzaic, Paul S.

    1991-06-01

    A detailed light budget is performed on reflective displays made from nematic droplet/polymer (NCAP) films incorporating dichroic dyes. It is shown that the radiance of these displays can be modeled using a simple scheme involving the convolution of the transmission spectra of the various components of the display. Comparisons are made between the relative importance of these optical elements in the display. It is shown that first-surface reflection (glare) is an important factor in reducing the optical performance of these displays, but that the effect of glare can be minimized through the proper choice of dye concentration.

  13. Relative sensitivity of clinical tests to hydrophilic lens-induced corneal thickness changes.

    PubMed

    Elliott, D B; Fonn, D; Flanagan, J; Doughty, M

    1993-12-01

    The relative sensitivity of the van den Berg Straylightmeter, slitlamp biomicroscopy, a modified optical pachometer, Bailey-Lovie logMAR visual acuity (VA), and two glare tests (The Brightness Acuity Tester used with 10% contrast VA and Pelli-Robson contrast sensitivity) to hydrophilic contact lens-induced edema was assessed in 19 subjects (mean age 25.9 +/- 4.5 years). After baseline assessments, subjects wore thick hydrogel lenses on one eye which was patched tightly for 3 h. Assessments were repeated at frequent intervals after lens removal to assess recovery. None of the pachometer measurements returned to baseline within the 2-h monitoring period, although the majority were within 2% of baseline corneal thickness. The average time for the Straylightmeter scores to recover to baseline values after the lens removal was 90 min, which was similar to the time when visible edema at the slitlamp disappeared. The average time for return to baseline of logMAR VA and the two glare tests was consistently two to three times shorter than the time for the Straylightmeter score. The Straylightmeter therefore provided assessments of corneal edema similar to slitlamp examination and was more sensitive than VA or glare testing.

  14. Glare on the Window

    NASA Image and Video Library

    2018-03-05

    In this image, NASA's Cassini sees Saturn and its rings through a haze of Sun glare on the camera lens. If you could travel to Saturn in person and look out the window of your spacecraft when the Sun was at a certain angle, you might see a view very similar to this one. Images taken using red, green and blue spectral filters were combined to show the scene in natural color. The images were taken with Cassini's wide-angle camera on June 23, 2013, at a distance of approximately 491,200 miles (790,500 kilometers) from Saturn. The Cassini spacecraft ended its mission on Sept. 15, 2017. https://photojournal.jpl.nasa.gov/catalog/PIA17185

  15. A double-blind, placebo-controlled study on the effects of lutein and zeaxanthin on photostress recovery, glare disability, and chromatic contrast.

    PubMed

    Hammond, Billy R; Fletcher, Laura M; Roos, Franz; Wittwer, Jonas; Schalch, Wolfgang

    2014-12-02

    Past studies have shown that higher macular pigment optical density (MPOD) and lutein (L) and zeaxanthin (Z) supplementation are related to improvements in glare disability, photostress recovery, and chromatic contrast. This study assessed those links using a randomized, double-blind, placebo-controlled design. The visual effects of 1 year of supplementing L (10 mg/d) and Z (2 mg/d) were investigated. One hundred fifteen young, healthy subjects were recruited and randomized into the study (58 received placebo, 57 L+Z). Several dependent measures were collected at baseline and then once every 3 months: serum L and Z measured by HPLC chromatography; MPOD measured using customized heterochromatic flicker photometry; photostress recovery assessed by measuring the time needed to recover visual acquisition of a grating target after 30 seconds of an intense xenon white flash exposure; glare disability evaluated as the energy in a surrounding annulus necessary to veil a central grating target; and chromatic contrast assessed by measuring thresholds for a yellow grating target superposed on a 460-nm background. Macular pigment optical density increased significantly versus placebo at all eccentricities (10, 30, 60, and 105 minutes from the center of the macula). Serum L and Z also increased significantly by the first follow-up visit (at 3 months), and remained elevated throughout the intervention period of 1 year. Chromatic contrast and photostress recovery time improved significantly versus placebo. Glare disability was correlated with macular pigment density throughout the study period but did not increase significantly in the treated group. Daily supplementation with L+Z resulted in significant increase in serum levels and MPOD and improvements in chromatic contrast and recovery from photostress. These results are consistent with past studies showing that increasing MPOD leads to improved visual performance. (ClinicalTrials.gov number, NCT00909090.). Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  16. Anti-glare LED lamps with adjustable illumination light field.

    PubMed

    Chen, Yung-Sheng; Lin, Chung-Yi; Yeh, Chun-Ming; Kuo, Chie-Tong; Hsu, Chih-Wei; Wang, Hsiang-Chen

    2014-03-10

    We introduce a type of LED light-gauge steel frame lamp with an adjustable illumination light field that does not require a diffusion plate. Base on the Monte Carlo ray tracing method, this lamp has a good glare rating (GR) of 17.5 at 3050 lm. Compared with the traditional LED light-gauge steel frame lamp (without diffusion plate), the new type has low GR. The adjustability of the illumination light field could improve the zebra effect caused by the inadequate illumination light field of the lamp. Meanwhile, we adopt the retinal image analysis to discuss the influence of GR on vision. High GR could reflect stray light on the retinal image, which will reduce vision clarity and hasten the feeling of eye fatigue.

  17. Position Index for the Matrix Light Source

    NASA Astrophysics Data System (ADS)

    Takahashi, Hiroshi; Kobayashi, Yoshinori; Onda, Shou; Irikura, Takashi

    It is expected that in the future white LEDs will be widely used in practical applications including replacing conventional lighting in offices and homes. The white LED light source of matrix arrangement is also considered in it. On the other hand, although now the unified glare rating (UGR) is widely used for evaluation of the discomfort glare of the interior lighting, UGR is a thing for a uniform light source, and its application to the matrix light sources that have non-uniform luminance has not been considered. The aim of this study is to clarify the position index which is one of element of UGR for the matrix light source. In this case, to apply the position index for a matrix light source to UGR, the concept of the revised position index is invented. As the preliminary experiment, method for measuring the position index was conducted, and as the experiment, position index for the matrix light source was conducted and compared with the uniform light source. The results of the experiments show that the position index is decided by the relative angle between line of sight and light source. It is also found that the matrix light source have larger position index than uniform light source. Furthermore, it is shown that the discomfort glare caused by a matrix light source can be evaluated by applying the revised position index to the UGR.

  18. Visual ergonomic aspects of glare on computer displays: glossy screens and angular dependence

    NASA Astrophysics Data System (ADS)

    Brunnström, Kjell; Andrén, Börje; Konstantinides, Zacharias; Nordström, Lukas

    2007-02-01

    Recently flat panel computer displays and notebook computer are designed with a so called glare panel i.e. highly glossy screens, have emerged on the market. The shiny look of the display appeals to the costumers, also there are arguments that the contrast, colour saturation etc improves by using a glare panel. LCD displays suffer often from angular dependent picture quality. This has been even more pronounced by the introduction of Prism Light Guide plates into displays for notebook computers. The TCO label is the leading labelling system for computer displays. Currently about 50% of all computer displays on the market are certified according to the TCO requirements. The requirements are periodically updated to keep up with the technical development and the latest research in e.g. visual ergonomics. The gloss level of the screen and the angular dependence has recently been investigated by conducting user studies. A study of the effect of highly glossy screens compared to matt screens has been performed. The results show a slight advantage for the glossy screen when no disturbing reflexes are present, however the difference was not statistically significant. When disturbing reflexes are present the advantage is changed into a larger disadvantage and this difference is statistically significant. Another study of angular dependence has also been performed. The results indicates a linear relationship between the picture quality and the centre luminance of the screen.

  19. Cataract

    MedlinePlus

    ... Colors that seem faded Glare - headlights, lamps or sunlight may seem too bright. You may also see ... a hat with a brim to block ultraviolet sunlight may help to delay cataracts. NIH: National Eye ...

  20. HDR imaging and color constancy: two sides of the same coin?

    NASA Astrophysics Data System (ADS)

    McCann, John J.

    2011-01-01

    At first, we think that High Dynamic Range (HDR) imaging is a technique for improved recordings of scene radiances. Many of us think that human color constancy is a variation of a camera's automatic white balance algorithm. However, on closer inspection, glare limits the range of light we can detect in cameras and on retinas. All scene regions below middle gray are influenced, more or less, by the glare from the bright scene segments. Instead of accurate radiance reproduction, HDR imaging works well because it preserves the details in the scene's spatial contrast. Similarly, on closer inspection, human color constancy depends on spatial comparisons that synthesize appearances from all the scene segments. Can spatial image processing play similar principle roles in both HDR imaging and color constancy?

  1. Emi-Flective Display Device with Attribute of High Glare-Free-Ambient-Contrast-Ratio

    NASA Astrophysics Data System (ADS)

    Yang, Bo-Ru; Hsu, Chuan-Wei; Shieh, Han-Ping D.

    2007-11-01

    We have demonstrated the integration of an organic light emitting device (OLED) and a reflective liquid crystal display (R-LCD) which was termed an emi-flective display. The glare-free-ambient-contrast-ratio (GFA-CR) was used to evaluate the image quality of display devices under ambient light. Through integrating the OLED with R-LCD, the GFA-CR of the device achieved an improvement by a factor of 8 compared with that of the OLED alone. Moreover, the integrated R-LCD showed a GFA-CR of 100:1 within a viewing cone of 20° which can suppress the wash-out of OLED and is more power-saving in the sunlight. Therefore, an emi-flective display is a promising technique for mobile applications.

  2. Optical eye simulator for laser dazzle events.

    PubMed

    Coelho, João M P; Freitas, José; Williamson, Craig A

    2016-03-20

    An optical simulator of the human eye and its application to laser dazzle events are presented. The simulator combines optical design software (ZEMAX) with a scientific programming language (MATLAB) and allows the user to implement and analyze a dazzle scenario using practical, real-world parameters. Contrary to conventional analytical glare analysis, this work uses ray tracing and the scattering model and parameters for each optical element of the eye. The theoretical background of each such element is presented in relation to the model. The overall simulator's calibration, validation, and performance analysis are achieved by comparison with a simpler model based uponCIE disability glare data. Results demonstrate that this kind of advanced optical eye simulation can be used to represent laser dazzle and has the potential to extend the range of applicability of analytical models.

  3. Approved CAR T cell therapies: ice bucket challenges on glaring safety risks and long-term impacts.

    PubMed

    Zheng, Ping-Pin; Kros, Johan M; Li, Jin

    2018-03-01

    Two autologous chimeric antigen receptor (CAR) T cell therapies (Kymriah™ and Yescarta™) were recently approved by the FDA. Kymriah™ is for the treatment of pediatric patients and young adults with refractory or relapse (R/R) B cell precursor acute lymphoblastic leukemia and Yescarta™ is for the treatment of adult patients with R/R large B cell lymphoma. In common, both are CD19-specific CAR T cell therapies lysing CD19-positive targets. Their dramatic efficacy in the short term has been highlighted by many media reports. By contrast, their glaring safety gaps behind the miracles remain much less addressed. Here, we focus on addressing the crucial challenges in relation to the gaps. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. In Saturn Shadow

    NASA Image and Video Library

    2006-10-11

    With giant Saturn hanging in the blackness and sheltering Cassini from the sun blinding glare, the spacecraft viewed the rings as never before, revealing previously unknown faint rings and even glimpsing its home world.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillesheim, Michael; Kandt, Alicen; Phillips, Steven

    The National Renewable Energy Laboratory, supporting the Department of the Navy Renewable Energy Program Office, has developed an innovative glint/glare analysis and visualization methodology to understand and mitigate the possible impacts of light reflecting off solar photovoltaic arrays.

  6. An Historic Overview of the Development of Fibre Metal Laminates

    NASA Astrophysics Data System (ADS)

    Vermeeren, C. A. J. R.

    2003-07-01

    In this paper a brief overview of the history of Fibre Metal Laminates Arall and Glare is given as background information for the other, technical articles in this journal. The story of the development of Fibre Metal Laminates is rather a unique story in the history of aircraft materials: A university laboratory invented, developed and certified an aircraft material. Many parties were involved naturally, yet the very heart of the activity was the Structures and Materials Laboratory of the Faculty of Aerospace Engineering of Delft University of Technology in The Netherlands. At the break of the world's largest passenger transport aircraft, the Airbus A380, in which a substantial part of the fuselage will be made of Glare, the glass fibre-aluminium version of Fibre Metal Laminates, it is a good moment to tell some of its history.

  7. Novel high-performance scattering materials for use in energy-saving light fittings and skylights based on polymer pigmented with polymer

    NASA Astrophysics Data System (ADS)

    Smith, Geoffrey B.; Earp, Alan; Franklin, Jim B.; McCredie, Geoffrey

    2001-11-01

    Simple quantitative performance criteria are developed for translucent materials in terms of hemispherical visible transmittance, and angular spread of transmitted luminance using a half angle. Criteria are linked to applications in luminaires and skylights with emphasis on maximising visible throughput while minimising glare. These basic criteria are also extended to angle of incidence changes which are substantial. Example data is provided showing that acrylic pigmented with spherical polymer particles can have total hemispherical transmittance with weak thickness dependence, which is better than clear sheet, while the spread of transmitted light is quite thickness-sensitive and occurs over wider angles than inorganic pigments. This combination means significantly fewer lamps can achieve specified lux levels with low glare, and smaller skylights can provide higher, more uniform daylight illuminance.

  8. The impact of faceplate surface characteristics on detection of pulmonary nodules

    NASA Astrophysics Data System (ADS)

    Toomey, R. J.; Ryan, J. T.; McEntee, M. F.; McNulty, J.; Evanoff, M. G.; Cuffe, F.; Yoneda, T.; Stowe, J.; Brennan, P. C.

    2009-02-01

    Introduction In order to prevent specular reflections, many monitor faceplates have features such as tiny dimples on their surface to diffuse ambient light incident on the monitor, however, this "anti-glare" surface may also diffuse the image itself. The purpose of the study was to determine whether the surface characteristics of monitor faceplates influence the detection of pulmonary nodules under low and high ambient lighting conditions. Methods and Materials Separate observer performance studies were conducted at each of two light levels (<1 lux and >250 lux). Twelve examining radiologists with the American Board of Radiology participated in the darker condition and eleven in the brighter condition. All observers read on both smooth "glare" and dimpled "anti-glare" faceplates in a single lighting condition. A counterbalanced methodology was utilized to minimise memory effects. In each reading, observers were presented with thirty chest images in random order, of which half contained a single simulated pulmonary nodule. They were asked to give their confidence that each image did or did not contain a nodule and to mark the suspicious location. ROC analysis was applied to resultant data. Results No statistically significant differences were seen in the trapezoidal area under the ROC curve (AUC), sensitivity, specificity or average time per case at either light level for chest specialists or radiologists from other specialities. Conclusion The characteristics of the faceplate surfaces do not appear to affect detection of pulmonary nodules. Further work into other image types is being conducted.

  9. Investigation of low-velocity impact damage in fibre-metal-laminates

    NASA Astrophysics Data System (ADS)

    Laliberte, Jeremy F.

    2002-04-01

    Fibre-metal-laminates (FMLs) represent a significant evolution in airframe material technology. This new family of materials combines low density, high strength and excellent damage tolerance through the use of metal layers strengthened with fibre-reinforced polymer layers. When subjected to low-velocity impact these laminates like traditional composites, develop internal delamination damage, matrix cracks and limited fibre fractures. Also, as in traditional composites, this damage is hidden within the laminate. A method for predicting the amount of internal damage would reduce the experimental testing requirements for the certification of new laminates. This thesis describes the development of a modelling methodology that makes use of a new material subroutine based on continuum damage mechanics in the explicit finite-element code LS-DYNA. This subroutine was verified using the experimental data from low-velocity impact tests of various types of GLARE (GLAss REinforced) aluminum laminates, a common type of commercially available fibre-metal-laminate. Static characterization tests were also conducted on GLARE coupons to provide basic property data for the development of the model. These included static tensile tests and double cantilever beam delamination tests. The modelling methodology was used to improve simulations of low-velocity impact on GLARE laminates. The simulations demonstrated that intralaminar damage has a greater effect on the impact response of the panels than interlaminar damage. Parts of this thesis were components of a multi-year collaborative FML Durability Project between Carleton University, Bombardier Aerospace and the National Research Council Canada.

  10. Effects of anti-glare particles on sedation in mice

    NASA Astrophysics Data System (ADS)

    Wang, Hongyu; Hao, Shaojun; Liu, Xiaobin; Kong, Xuejun; Wang, Xidong; Li, Wenjun; Zhang, Zhengchen

    2018-04-01

    To investigate the effect of anti-glare particles on sedation of mice, 60 mice were randomly divided into 5 groups, were fed by Ant-dizzy Granule Suspension, saline, Yang Xue Qing Nao Granule suspension and the same volume of saline, and administered 1 times daily, for 7 days. The mice in the wilderness box, hang - 150W light bulbs in the box above, the light recording activities within 2 minutes. The wilderness box into the box after the number of mice, mice with limbs went to the 1 squares is around 1 in the same case, mouse location and method of wilderness case; each group was placed in the turn/bar with rotating speed of 40RPM, each time 5 Parallel experiment recorded the mouse stay time on the rotating rod, if the mouse fell within 2 minutes, immediately put it on the rotating rod to continue the experiment, recorded the mouse on the rotating rod accumulated stay time. If 10 minutes did not drop, press 10 minutes; eighty mice were divided into 5 groups. The number of each rat injected subthreshold dose of pentobarbital sodium in mice. The sleep recording liquid were recorded sleep latency and sleep time. The anti-vertigo granule can obviously reduce the spontaneous activity of mice (P<0.05), can significantly increase the residence time of mice on the rotating rod (P<0.05) have obvious synergistic effect (P<0.05). Anti-glare particles have good sedative effect.

  11. Changes in the Body with Aging

    MedlinePlus

    ... interfere with lubricating the eyeball and contribute to dry eyes. The eye may appear to sink into the ... in the lens of the eye increase glare. Dry eyes The number of cells that produce fluids to ...

  12. The Eyes Have It | NIH MedlinePlus the Magazine

    MedlinePlus

    ... seem faded. Seeing a glare. Headlights, lamps, or sunlight may appear too bright. A halo may appear ... related cataracts. These studies include: The effect of sunlight exposure, which may be associated with an increased ...

  13. Adaptive driving beam headlights : visibility, glare and measurement considerations.

    DOT National Transportation Integrated Search

    2016-06-01

    Recent developments in solid-state lighting, sensor and control technologies are making new : configurations for vehicle forward lighting feasible. Building on systems that automatically switch from : high- to low-beam headlights in the presence of o...

  14. Harassment: Imaginings.

    ERIC Educational Resources Information Center

    Wilt, Judith

    1993-01-01

    Imagines the role of the male college professor in view of the erotic and sexual nature of his subjectivity and the glaring possibilities of sexual misconduct with students. Outlines some experiences related to the sexual harassment policies of one private college. (HB)

  15. Education

    ERIC Educational Resources Information Center

    Conde, David

    1977-01-01

    Today there is a need for an increasing number of properly trained Spanish-speaking and culturally sensitive teachers and administrators. The glaring disparity between the number of bilingual educators at all levels and the Hispanic American population manifest this as a priority. (Author/NQ)

  16. A novel full-angle scanning light scattering profiler to quantitatively evaluate forward and backward light scattering from intraocular lenses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Bennett N., E-mail: bennett.walker@fda.hhs.gov; Office of Device Evaluation, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993; James, Robert H.

    Glare, glistenings, optical defects, dysphotopsia, and poor image quality are a few of the known deficiencies of intraocular lenses (IOLs). All of these optical phenomena are related to light scatter. However, the specific direction that light scatters makes a critical difference between debilitating glare and a slightly noticeable decrease in image quality. Consequently, quantifying the magnitude and direction of scattered light is essential to appropriately evaluate the safety and efficacy of IOLs. In this study, we introduce a full-angle scanning light scattering profiler (SLSP) as a novel approach capable of quantitatively evaluating the light scattering from IOLs with a nearlymore » 360° view. The SLSP method can simulate in situ conditions by controlling the parameters of the light source including angle of incidence. This testing strategy will provide a more effective nonclinical approach for the evaluation of IOL light scatter.« less

  17. Correlations between internal and external ocular factors and macular pigment optical density.

    PubMed

    Tudosescu, Ruxandra; Alexandrescu, Cristina Mihaela; Istrate, Sânziana Luminiţa; Vrapciu, Alexandra Diana; Ciuluvică, Radu Constantin; Voinea, Liliana

    2018-01-01

    To assess the relationship between the macular pigment optical density and blue-light issued by computers, glare sensibility, with iris color, age, sex, or refractive errors. 83 patients (166 eyes) were enrolled in a prospective observational study. They were divided into 2 groups: group 1 (study group) - computer using patients (time spent in front of the computer for minimum 8 hours per day, 5 days per week, 2 years) - 43 patients and group 2 (control group) - 40 patients. The following investigations were conducted in all the selected cases: visual acuity, refraction, biomicroscopy, measurement of the MPOD, glare sensitivity, assessment of eye color. 51.81% of the patients were included in group 1, while the rest, 48.19%, were in group 2. Thus, the MPOD had a mean value of (+/ -SD) 0.42+/ -0.13 (t = -1.08, p = 0.28) in group 1, and 0.44+/ -0.16 on the LE. The results showed a MPOD mean value of 0.51+/ - 0.16 in group 2 and 0.51+/ -0 .16. (t = 0.49, p = 0 .62) on the LE. 55.77% of the patients with light colored iris and 56.14% of those with dark iris had a low MPOD. The data from our study failed to illustrate a significant correlation between MPOD and blue-light issued by computers. Furthermore, a statistic significant relationship regarding iris color, refractive errors, glare, and MPOD was not observed. L = lutein, Z = zeaxanthin, MZ = meso-zeaxanthin, AMD = age related macular degeneration, MPOD = macular pigment optical density, MP = macular pigment, HFP = Heterochromatic Flicker Photometry, RE = right eye, LE = left eye.

  18. Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation

    PubMed Central

    Tchah, Hungwon; Nam, Kiyeun; Yoo, Aeri

    2017-01-01

    AIM To investigate the independent factors associated with photic phenomena in patients implanted with refractive, rotationally asymmetric, multifocal intraocular lenses (MIOLs). METHODS Thirty-four eyes of 34 patients who underwent unilateral cataract surgery, followed by implantation of rotationally asymmetric MIOLs were included. Distance and near visual acuity outcomes, intraocular aberrations, preferred reading distances, preoperative and postoperative refractive errors, mesopic and photopic pupil diameters, and the mesopic and photopic kappa angles were assessed. Patients were also administered a satisfaction survey. Photic phenomena were graded by questionnaire. Independent-related factors were identified by correlation and bivariate logistic regression analyses. RESULTS The distance from the photopic to the mesopic pupil center (pupil center shift) was significantly associated with glare/halo symptoms [odds ratio (OR)=2.065, 95% confidence interval (CI)=0.916-4.679, P=0.006] and night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007). The preoperative photopic angle kappa was significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041). The photopic angle kappa was also significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041) and with night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007) in patients implanted with rotationally asymmetric MIOLs. CONCLUSION A large pupil center shift and misalignment between the visual and pupillary axis (angle kappa) may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs. PMID:28251083

  19. Wintering birds avoid warm sunshine: predation and the costs of foraging in sunlight.

    PubMed

    Carr, Jennie M; Lima, Steven L

    2014-03-01

    Wintering birds can gain significant thermal benefits by foraging in direct sunlight. However, exposure to bright sunlight might make birds easier to detect by predators and may also cause visual glare that can reduce a bird's ability to monitor the environment. Thus, birds likely experience a trade-off between the thermal benefits and predation-related costs of foraging in direct sunlight. To examine this possible thermoregulation-predation trade-off, we monitored the behavior of mixed-species flocks of wintering emberizid sparrows foraging in alternating strips of sunlight and shade. On average, these sparrows routinely preferred to forage in the shade, despite midday air temperatures as much as 30 °C below their thermoneutral zone. This preference for shade was strongest at relatively high temperatures when the thermal benefits of foraging in sunlight were reduced, suggesting a thermoregulation-predation trade-off. Glare could be reduced if birds faced away from the sun while feeding in direct sunlight, but we found that foraging birds tended to face southward (the direction of the sun). We speculate that other factors, such as the likely direction of predator approach, may explain this southerly orientation, particularly if predators use solar glare to their advantage during an attack. This interpretation is supported by the fact that birds had the weakest southerly orientation on cloudy days. Wintering birds may generally avoid foraging in direct sunlight to minimize their risk of predation. However, given the thermal benefits of sunshine, such birds may benefit from foraging in habitats that provide a mosaic of sunlit and shaded microhabitats.

  20. Contrast visual acuity in patients with retinitis pigmentosa assessed by a contrast sensitivity tester.

    PubMed

    Oishi, Maho; Nakamura, Hajime; Hangai, Masanori; Oishi, Akio; Otani, Atsushi; Yoshimura, Nagahisa

    2012-01-01

    To assess contrast visual acuity (CVA) in patients with retinitis pigmentosa (RP) and compare the result with standard visual acuity (VA), retinal thickness, status of inner segment/outer segment junction, and central visual field. Thirty-nine eyes of 39 patients with RP and 39 eyes of 39 healthy individuals were studied. To see the difference in CVA between RP patients and normal controls, only subjects with standard VA of 1.0 (20/20) or better were included. This was a cross-sectional study. CVA in various light conditions was measured with CAT-2000 and was compared between patients and controls. CVA of patients was further analyzed for association with other parameters including foveal retinal thickness, outer nuclear layer thickness, the status of inner segment/outer segment junction measured with optical coherence tomography (OCT), and visual field mean deviation (MD) measured with Humphrey field analyzer 10-2 program. CVA impairment was evident in RP patients compared to controls (P < 0.01, in all measurement conditions). Multivariate analysis showed association of logarithm of the minimum angle of resolution (logMAR) with CVAs in several conditions. None of the OCT measurements was associated with CVA. When patients were divided into three groups based on MD, the most advanced group (MD worse than or equal to -20 dB) showed impairment of mesopic CVA (P < 0.05, under mesopic condition of 100% without glare, with glare, and 25% without glare). CVA impairment was confirmed in RP patients, especially in advanced cases. CVA measured with CAT-2000 may be a useful tool for assessing foveal function in RP patients.

  1. Vision and night driving abilities of elderly drivers.

    PubMed

    Gruber, Nicole; Mosimann, Urs P; Müri, René M; Nef, Tobias

    2013-01-01

    In this article, we review the impact of vision on older people's night driving abilities. Driving is the preferred and primary mode of transport for older people. It is a complex activity where intact vision is seminal for road safety. Night driving requires mesopic rather than scotopic vision, because there is always some light available when driving at night. Scotopic refers to night vision, photopic refers to vision under well-lit conditions, and mesopic vision is a combination of photopic and scotopic vision in low but not quite dark lighting situations. With increasing age, mesopic vision decreases and glare sensitivity increases, even in the absence of ocular diseases. Because of the increasing number of elderly drivers, more drivers are affected by night vision difficulties. Vision tests, which accurately predict night driving ability, are therefore of great interest. We reviewed existing literature on age-related influences on vision and vision tests that correlate or predict night driving ability. We identified several studies that investigated the relationship between vision tests and night driving. These studies found correlations between impaired mesopic vision or increased glare sensitivity and impaired night driving, but no correlation was found among other tests; for example, useful field of view or visual field. The correlation between photopic visual acuity, the most commonly used test when assessing elderly drivers, and night driving ability has not yet been fully clarified. Photopic visual acuity alone is not a good predictor of night driving ability. Mesopic visual acuity and glare sensitivity seem relevant for night driving. Due to the small number of studies evaluating predictors for night driving ability, further research is needed.

  2. Light and Libraries.

    ERIC Educational Resources Information Center

    Scherer, Jeffrey

    1999-01-01

    Addresses how to integrate various types of light within the context of library design. Discusses light basics; the light spectrum; light measurement; reflectance; glare and brightness ratio; daylighting; electric lighting; and computer screens and lighting. Includes a checklist for plan review. (Author/LRW)

  3. Refractive surgery in aircrew members who fly for scheduled and nonscheduled civilian airlines : final report.

    DOT National Transportation Integrated Search

    2000-05-01

    Introduction. Civil airmen with refractive surgery are present in all classes of aeromedical certificate holders. Refractive surgical procedures have been associated with numerous side effects, including glare, reduced contrast sensitivity, and fluct...

  4. 23 CFR 750.108 - General provisions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... directed at any portion of the main-traveled way of the Interstate System, or is of such low intensity or brilliance as not to cause glare or to impair the vision of the driver of any motor vehicle, or to otherwise...

  5. 23 CFR 750.108 - General provisions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... directed at any portion of the main-traveled way of the Interstate System, or is of such low intensity or brilliance as not to cause glare or to impair the vision of the driver of any motor vehicle, or to otherwise...

  6. 23 CFR 750.108 - General provisions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... directed at any portion of the main-traveled way of the Interstate System, or is of such low intensity or brilliance as not to cause glare or to impair the vision of the driver of any motor vehicle, or to otherwise...

  7. 23 CFR 750.108 - General provisions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... directed at any portion of the main-traveled way of the Interstate System, or is of such low intensity or brilliance as not to cause glare or to impair the vision of the driver of any motor vehicle, or to otherwise...

  8. 77 FR 13525 - Safety Zone; Rocketts Red Glare Fireworks, Ancarrows Landing Park, James River, Richmond, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-07

    ... enclose a stamped, self-addressed postcard or envelope. We will consider all comments and material..., dangerous projectiles, and falling hot embers or other debris, vessel traffic will be temporarily restricted...

  9. Improving School Lighting for Video Display Units.

    ERIC Educational Resources Information Center

    Parker-Jenkins, Marie; Parker-Jenkins, William

    1985-01-01

    Provides information to identify and implement the key characteristics which contribute to an efficient and comfortable visual display unit (VDU) lighting installation. Areas addressed include VDU lighting requirements, glare, lighting controls, VDU environment, lighting retrofit, optical filters, and lighting recommendations. A checklist to…

  10. 23 CFR 750.106 - Class 3 and 4 signs within informational sites.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the main-traveled way of the Interstate System, or is of such low intensity or brilliance as not to cause glare or to impair the vision of the driver of any motor vehicle, or to otherwise interfere with...

  11. 23 CFR 750.106 - Class 3 and 4 signs within informational sites.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the main-traveled way of the Interstate System, or is of such low intensity or brilliance as not to cause glare or to impair the vision of the driver of any motor vehicle, or to otherwise interfere with...

  12. 23 CFR 750.106 - Class 3 and 4 signs within informational sites.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the main-traveled way of the Interstate System, or is of such low intensity or brilliance as not to cause glare or to impair the vision of the driver of any motor vehicle, or to otherwise interfere with...

  13. Musculoskeletal, visual and psychosocial stress in VDU operators after moving to an ergonomically designed office landscape.

    PubMed

    Helland, Magne; Horgen, Gunnar; Kvikstad, Tor Martin; Garthus, Tore; Bruenech, Jan Richard; Aarås, Arne

    2008-05-01

    This study investigated the effect of moving from single occupancy offices to a landscape environment. Thirty-four Visual Display Unit (VDU) operators reported significantly worsened condition of lighting and glare in addition to increased visual discomfort. For visual discomfort, the difference with 95% confidence interval was 10.7 (1.9-19.5) Visual Analog Scale (VAS) as group mean value. The most reasonable explanation for these results may be that the operators were glared from high luminance from the windows, when the Venetian blinds were not properly used. Glare was significantly correlated with visual discomfort, rs=0.35. Both illuminance and luminance in the work area, and contrast reduction on the VDU screen were in line with recommendations from CIE for VDU work. In a regression analysis, the visual discomfort explained 53% of the variance in the neck and shoulder pain. In the office landscape, the eye blink rate during habitual VDU work was recorded for 12 randomly selected operators from the 34 participants. A marked drop in eye blink rate during VDU work was found when this was compared to "easy conversation" (VDU work, mean=9.7 blinks per minute; "easy conversation," mean=21.4 blinks per minute). Participants reported many of the organizational and psychosocial conditions and work factors worse when landscape office was compared to single occupancy office. These factors may have influenced the musculoskeletal pain. However, the pain level was still low at 6 years and not significantly different when compared with the start of the study period, except for a small but significant increase in shoulder pain. In this study, visual discomfort is clearly associated with pain in the neck and shoulder area.

  14. Static and Dynamic Behavior of High Modulus Hybrid Boron/Glass/Aluminum Fiber Metal Laminates

    NASA Astrophysics Data System (ADS)

    Yeh, Po-Ching

    2011-12-01

    This dissertation presents the investigation of a newly developed hybrid fiber metal laminates (FMLs) which contains commingled boron fibers, glass fibers, and 2024-T3 aluminum sheets. Two types of hybrid boron/glass/aluminum FMLs are developed. The first, type I hybrid FMLs, contained a layer of boron fiber prepreg in between two layers of S2-glass fiber prepreg, sandwiched by two aluminum alloy 2024-T3 sheets. The second, type II hybrid FMLs, contained three layer of commingled hybrid boron/glass fiber prepreg layers, sandwiched by two aluminum alloy 2024-T3 sheets. The mechanical behavior and deformation characteristics including blunt notch strength, bearing strength and fatigue behavior of these two types of hybrid boron/glass/aluminum FMLs were investigated. Compared to traditional S2-glass fiber reinforced aluminum laminates (GLARE), the newly developed hybrid boron/glass/aluminum fiber metal laminates possess high modulus, high yielding stress, and good blunt notch properties. From the bearing test result, the hybrid boron/glass/aluminum fiber metal laminates showed outstanding bearing strength. The high fiber volume fraction of boron fibers in type II laminates lead to a higher bearing strength compared to both type I laminates and traditional GLARE. Both types of hybrid FMLs have improved fatigue crack initiation lives and excellent fatigue crack propagation resistance compared to traditional GLARE. The incorporation of the boron fibers improved the Young's modulus of the composite layer in FMLs, which in turn, improved the fatigue crack initiation life and crack propagation rates of the aluminum sheets. Moreover, a finite element model was established to predict and verify the properties of hybrid boron/glass/aluminum FMLs. The simulated results showed good agreement with the experimental results.

  15. Visual Results Following Implantation of a Refractive Multifocal Intraocular Lens in One Eye and a Diffractive in the Contralateral Eye

    PubMed Central

    Yıldırım Karabağ, Revan; Günenç, Üzeyir; Aydın, Rukiye; Arıkan, Gül; Aslankara, Hüseyin

    2018-01-01

    Objectives To assess the visual outcomes in patients who underwent cataract surgery with multifocal intraocular lens (IOL) implantation using a “mix and match” approach. Materials and Methods Twenty patients (40 eyes) were involved in this prospective, nonrandomized study. Refractive multifocal IOLs (ReZoom NXG1) were implanted in patients’ dominant eyes and diffractive multifocal IOLs (Tecnis ZMA00) were implanted in their non-dominant eyes. Monocular and binocular uncorrected distance, intermediate and near visual acuity (logMAR), and contrast sensitivity levels were measured at 1, 3, and 6 months after cataract surgery. Defocus curves, reading speeds, patient satisfaction, spectacle dependence, and halo and glare symptoms were also evaluated at 6 months after the surgery. Postoperative quality of life was assessed with the Turkish version of National Eye Institute Visual Function Questionnaire-25. Results The study group comprised 8 females and 12 males with a mean age of 69.45±10.76 years (range, 31-86 years). The uncorrected distance and intermediate visual acuity levels were significantly better in the ReZoom-implanted eyes at postoperative 6 months (p=0.026 and p=0.037, respectively). There was no statistically significant difference in uncorrected near visual acuity (p>0.05). There was no statistically significant difference in contrast sensitivity, reading speed, halos, or glare between the groups (p<0.05). Mild glare/halo was reported by 40% of the subjects. The mean patient satisfaction was 95% and all patients were spectacle independent. Conclusion Mixing and matching multifocal IOLs in selected cataract patients provides excellent visual outcome, a high level of patient satisfaction, and spectacle independency. PMID:29576891

  16. Getting Pool Light Right.

    ERIC Educational Resources Information Center

    Hunsaker, Scot

    1998-01-01

    Examines the use of lighting, both artificial and natural, that can enhance the aesthetic quality and functionality of areas with indoor swimming pools. Discusses glare and shadow-reduction measures that aid competitive events, including lighting above and below water levels, and highlights lighting issues during televised events. Descriptions of…

  17. Aging and Visual Impairment.

    ERIC Educational Resources Information Center

    Morse, A. R.; And Others

    1987-01-01

    Eye diseases of the aged include diabetic retinopathy, senile cataracts, senile macular degeneration, and glaucoma. Environmental modifications such as better levels of illumination and reduction of glare can enhance an individual's ability to function. Programs to screen and treat visual problems in elderly persons are called for. (Author/JDD)

  18. The Eyes Have It.

    ERIC Educational Resources Information Center

    Walsh, Janet

    1982-01-01

    Discusses issues related to possible health hazards associated with viewing video display terminals. Includes some findings of the 1979 NIOSH report on Potential Hazards of Video Display Terminals indicating level of radiation emitted is low and providing recommendations related to glare and back pain/muscular fatigue problems. (JN)

  19. Planetary Hot Spot Not Under the Glare of Star Artist Concept

    NASA Image and Video Library

    2010-10-19

    This artist concept based on data found by NASA Spitzer Space Telescope shows upsilon Andromedae b, a hot gas giant that whips around its star every 4.6 days. Because it is so close to its star, it is tidally locked.

  20. Effects of Colored Filters on Visual Function

    DTIC Science & Technology

    2008-05-01

    normal vision, yellow filters have been reported to reduce glare and improve overall visual performance.4-9 The claims of improved vision in dyslexia ...use of tinted lenses and colored overlays for the treatment of dyslexia and other related reading and learning disorders. American Optometric

  1. Creating a Discourse of Difference

    ERIC Educational Resources Information Center

    Fisher, Anne-Claire

    2007-01-01

    Recent educational policy has attempted to alleviate glaring achievement gaps within increasingly diverse student groups in the USA. Despite these efforts districts not making yearly Adequate Yearly Progress (AYP) are predominantly in disenfranchised areas or may be serving very diverse students. This article showcases recent research, which has…

  2. Lighting for Our Schools.

    ERIC Educational Resources Information Center

    Rankin, John C.

    In this speech, the author traces the history of lighting in schools, discusses the variables affecting the amount of illuminance needed, and provides a table of illuminances recommended for Ontario schools. Other factors that affect vision--glare, veiling reflection, color, and brightness balance--are outlined. Planners are admonished to…

  3. The use of near-infrared photography to image fired bullets and cartridge cases.

    PubMed

    Stein, Darrell; Yu, Jorn Chi Chung

    2013-09-01

    An imaging technique that is capable of reducing glare, reflection, and shadows can greatly assist the process of toolmarks comparison. In this work, a camera with near-infrared (near-IR) photographic capabilities was fitted with an IR filter, mounted to a stereomicroscope, and used to capture images of toolmarks on fired bullets and cartridge cases. Fluorescent, white light-emitting diode (LED), and halogen light sources were compared for use with the camera. Test-fired bullets and cartridge cases from different makes and models of firearms were photographed under either near-IR or visible light. With visual comparisons, near-IR images and visible light images were comparable. The use of near-IR photography did not reveal more details and could not effectively eliminate reflections and glare associated with visible light photography. Near-IR photography showed little advantages in manual examination of fired evidence when it was compared with visible light (regular) photography. © 2013 American Academy of Forensic Sciences.

  4. KENNEDY SPACE CENTER, FLA. - From a burst of fire and smoke, the Delta II launch vehicle races into the sky carrying the second Mars Exploration Rover, Opportunity. The bright glare briefly illuminated Florida Space Coast beaches. Opportunity’s dash to Mars began with liftoff at 11:18:15 p.m. Eastern Daylight Time from Cape Canaveral Air Force Station, Fla. The spacecraft separated successfully from the Delta's third stage 83 minutes later, after it had been boosted out of Earth orbit and onto a course toward Mars.

    NASA Image and Video Library

    2003-07-07

    KENNEDY SPACE CENTER, FLA. - From a burst of fire and smoke, the Delta II launch vehicle races into the sky carrying the second Mars Exploration Rover, Opportunity. The bright glare briefly illuminated Florida Space Coast beaches. Opportunity’s dash to Mars began with liftoff at 11:18:15 p.m. Eastern Daylight Time from Cape Canaveral Air Force Station, Fla. The spacecraft separated successfully from the Delta's third stage 83 minutes later, after it had been boosted out of Earth orbit and onto a course toward Mars.

  5. 47 CFR 2.955 - Retention of records.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Retention of records. 2.955 Section 2.955 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL... information contained in the test report. Any photographs used must be focused originals without glare or dark...

  6. 47 CFR 2.955 - Retention of records.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Retention of records. 2.955 Section 2.955 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL... information contained in the test report. Any photographs used must be focused originals without glare or dark...

  7. 47 CFR 2.955 - Retention of records.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Retention of records. 2.955 Section 2.955 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL... information contained in the test report. Any photographs used must be focused originals without glare or dark...

  8. 47 CFR 2.955 - Retention of records.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Retention of records. 2.955 Section 2.955 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL... information contained in the test report. Any photographs used must be focused originals without glare or dark...

  9. Putting the Glare of Publicity on International Arms Sales.

    ERIC Educational Resources Information Center

    Hartman, William

    1992-01-01

    Reports on a United Nations committee recommendation that the Security Council establish a universal register of arms. Suggests that such a register would limit the destabilizing influence of major arms sales on developing nations. Argues that visibility of arms sales may help reduce their number. (DK)

  10. Nominal Ocular Dazzle Distance (NODD)

    DTIC Science & Technology

    2015-02-23

    retinal areas [14–16]. There is also a smaller contribution from the ocular wall [17], comprising the sclera and the iris . These internal scatter...retina, forma - tion and duration of afterimages in the case of Class 1 laser products, and disability glare arising from high-brightness light emitting

  11. 47 CFR 2.955 - Retention of records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Retention of records. 2.955 Section 2.955 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL... information contained in the test report. Any photographs used must be focused originals without glare or dark...

  12. Development of an NCHRP report 350 TL-3 New Jersey shape 50-inch portable concrete barrier : executive summary report.

    DOT National Transportation Integrated Search

    2006-06-01

    The purpose of the project was to develop a : temporary portable concrete barrier (PCB) : with an integral glare shield for use in : roadside work-zone areas. Currentlyavailable : 32-inch portable concrete barriers : require the use of an add-on glar...

  13. Early-Stage Software Design for Usability

    ERIC Educational Resources Information Center

    Golden, Elspeth

    2010-01-01

    In spite of the goodwill and best efforts of software engineers and usability professionals, systems continue to be built and released with glaring usability flaws that are costly and difficult to fix after the system has been built. Although user interface (UI) designers, be they usability or design experts, communicate usability requirements to…

  14. Suggestions for Early Motion Picture Research.

    ERIC Educational Resources Information Center

    Jowett, Garth S.

    Only by examining the motion picture as a mass medium, shaped and defined within a specific socio-cultural period in history, can we increase our understanding of the function and contribution of this entertainment form. This paper offers several suggestions for further research into early motion picture history. One glaring deficiency among…

  15. Translations on Eastern Europe Political, Sociological, and Military Affairs, Number 1332

    DTIC Science & Technology

    1976-12-13

    building sites of the big projects, in some work that we have seen at the exposi - tions on the navy or air force, and so forth, were pale and anemic...countries by the fact that we will have ab - solutely no glaring poverty, nowhere. 1015 - TB - CSO: 2600

  16. "The Older Women Are Men:" Navigating the Academic Terrain, Perspectives from Ghana

    ERIC Educational Resources Information Center

    Mabokela, Reitumetse Obakeng; Mlambo, Yeukai Angela

    2015-01-01

    This qualitative study investigates how the intersection of gender, socio-cultural factors, and organizational culture impact professional experiences of women academics at a selected public university in Ghana. Given the glaring absence of women in academic positions across many African universities, particularly at academic ranks beyond the…

  17. Failing Liberty 101

    ERIC Educational Resources Information Center

    Damon, William

    2012-01-01

    The author presents evidence of "glaring gaps in U.S. students' civic knowledge, motivation, and interest." From the inception of the United States through the mid-20th century, he writes, civic education was at the center of U.S. schooling. Since then, however, there has been a decline in civics instruction, fueled by increasing…

  18. N-Acetylcarnosine sustained drug delivery eye drops to control the signs of ageless vision: glare sensitivity, cataract amelioration and quality of vision currently available treatment for the challenging 50,000-patient population.

    PubMed

    Babizhayev, Mark A; Burke, Leslie; Micans, Philip; Richer, Stuart P

    2009-01-01

    Innovative Vision Products, Inc. (IVP)'s scientists developed the lubricant eye drops (Can-C) designed as 1% N-acetylcarnosine (NAC) prodrug of L-carnosine containing a mucoadhesive cellulose-based compound combined with corneal absorption promoters in a sustained drug delivery system. Only the natural L-isomeric form of NAC raw material was specifically synthesized at the cGMP facility and employed for the manufacturing of Can-C eye drops. In the present clinical study the authors assessed vision before and after 9 month term of topical ocular administration of NAC lubricant eye drops or placebo in 75 symptomatic patients with age-related uncomplicated cataracts in one or both eyes, with acuity in one eye of 20/40 or worse (best-corrected distance), and no previous cataract surgery in either eye and no other ocular abnormality and 72 noncataract subjects ranged in age from 54 to 78 years. Subjects in these subsample groups have reported complaints of glare and wanted to administer eye drops to get quick eye relief and quality of vision for their daily activities including driving and computer works. Following 9 months of treatment with NAC lubricant eye drops, most patients' glare scores were improved or returned to normal in disability glare tests with Halometer DG. Improvement in disability glare was accompanied with independent improvement in acuity. Furthermore, patients with the poorest pretreatment vision were as likely to regain certain better visual function after 9 months of treatment with N-acetylcarnosine lubricant eye drops as those with the worth pretreatment vision. The authors made a reference to electronic records of the product sales to patients who have been made the repurchase of the Can-C eye drops since December 2001. Based on this analysis of recorded adjustments to inventory, various parameters were analyzed during the continued repurchase behavior program, including testimonials from buyers. With these figures, researchers judged on the patients' compliance rate to self-administer NAC eye-drops. The ophthalmic drug showed potential for the non-surgical treatment of age-related cataracts for participants after controlling for age, gender and daily activities and on a combined basis of repurchases behavior reports in more than 50,000 various cohort survivors, has been demonstrated to have a high efficacy and good tolerability for prevention and treatment of visual impairment determined for the older population with relative stable pattern of causes for blindness and visual impairment. The mechanisms of prevention and reversal of cataracts with NAC ophthalmic drug are considered which include prevention by the intraocular released carnosine of free-radical-induced inactivation of proprietary lens antioxidant enzymes (superoxide dismutase); prevention of carbohydrate and metal-catalyzed autooxidation of ascorbic acid-induced cross-linking glycation reactions to the lens proteins; transglycation properties of carnosine, allowing it to compete for the glycating agent, protecting proteins (lens crystallins) against modification; universal antioxidant and scavenging activity towards lipid hydroperoxides, aldehydes and oxygen radicals; activation with l-carnosine ingredient of proteasome activity in the lens; chaperone-like disaggregating to lens crystallins activity of NAC and of its bioactivated principal carnosine. Blindness incidence increased with advancing age, such as cataract and glaucoma, which are by far the commonest causes of blindness in our sample and in all age groups, glaucomatous neurodegeneration can be treated with developed NAC autoinduction prodrug eye drops equipped with corneal absorption promoters. The common blinding affections presenting in developed countries such as, senile macular degeneration, hereditary chorioretinal dystrophies, diabetic retinopathy are poorly represented in our current summary of vital-statistics and will be reported inherent in next N-acetylcarnosine ophthalmic drug studies. The authors present evidence, about why only a certain kind of NAC is safe, and why only certain formulas designed by IVP for drug discovery are efficacious in the prevention and treatment of senile cataract for long-term use. Overall cumulated studies demonstrate that the designed by IVP new vision-saving drug NAC eye drops help the aging eye to recover by improving its clarity, glare sensitivity, color perception and overall vision.

  19. N-Acetylcarnosine sustained drug delivery eye drops to control the signs of ageless vision: Glare sensitivity, cataract amelioration and quality of vision currently available treatment for the challenging 50,000-patient population

    PubMed Central

    Babizhayev, Mark A; Burke, Leslie; Micans, Philip; Richer, Stuart P

    2009-01-01

    Background: Innovative Vision Products, Inc. (IVP)’s scientists developed the lubricant eye drops (Can-C™) designed as 1% N-acetylcarnosine (NAC) prodrug of l-carnosine containing a mucoadhesive cellulose-based compound combined with corneal absorption promoters in a sustained drug delivery system. Only the natural l-isomeric form of NAC raw material was specifically synthesized at the cGMP facility and employed for the manufacturing of Can-C™ eye drops. Objective and study design: In the present clinical study the authors assessed vision before and after 9 month term of topical ocular administration of NAC lubricant eye drops or placebo in 75 symptomatic patients with age-related uncomplicated cataracts in one or both eyes, with acuity in one eye of 20/40 or worse (best-corrected distance), and no previous cataract surgery in either eye and no other ocular abnormality and 72 noncataract subjects ranged in age from 54 to 78 years. Setting: Subjects in these subsample groups have reported complaints of glare and wanted to administer eye drops to get quick eye relief and quality of vision for their daily activities including driving and computer works. Following 9 months of treatment with NAC lubricant eye drops, most patients’ glare scores were improved or returned to normal in disability glare tests with Halometer DG. Improvement in disability glare was accompanied with independent improvement in acuity. Furthermore, patients with the poorest pretreatment vision were as likely to regain certain better visual function after 9 months of treatment with N-acetylcarnosine lubricant eye drops as those with the worth pretreatment vision. Patients or other participants: The authors made a reference to electronic records of the product sales to patients who have been made the repurchase of the Can-C™ eye drops since December 2001. Intervention: Based on this analysis of recorded adjustments to inventory, various parameters were analyzed during the continued repurchase behavior program, including testimonials from buyers. With these figures, researchers judged on the patients’ compliance rate to self-administer NAC eye-drops. Main outcome measure and results: The ophthalmic drug showed potential for the non-surgical treatment of age-related cataracts for participants after controlling for age, gender and daily activities and on a combined basis of repurchases behavior reports in more than 50,000 various cohort survivors, has been demonstrated to have a high efficacy and good tolerability for prevention and treatment of visual impairment determined for the older population with relative stable pattern of causes for blindness and visual impairment. The mechanisms of prevention and reversal of cataracts with NAC ophthalmic drug are considered which include prevention by the intraocular released carnosine of free-radical-induced inactivation of proprietary lens antioxidant enzymes (superoxide dismutase); prevention of carbohydrate and metal-catalyzed autooxidation of ascorbic acid-induced cross-linking glycation reactions to the lens proteins; transglycation properties of carnosine, allowing it to compete for the glycating agent, protecting proteins (lens crystallins) against modification; universal antioxidant and scavenging activity towards lipid hydroperoxides, aldehydes and oxygen radicals; activation with l-carnosine ingredient of proteasome activity in the lens; chaperone-like disaggregating to lens crystallins activity of NAC and of its bioactivated principal carnosine. Blindness incidence increased with advancing age, such as cataract and glaucoma, which are by far the commonest causes of blindness in our sample and in all age groups, glaucomatous neurodegeneration can be treated with developed NAC autoinduction prodrug eye drops equipped with corneal absorption promoters. The common blinding affections presenting in developed countries such as, senile macular degeneration, hereditary chorioretinal dystrophies, diabetic retinopathy are poorly represented in our current summary of vital-statistics and will be reported inherent in next N-acetylcarnosine ophthalmic drug studies. Conclusion: The authors present evidence, about why only a certain kind of NAC is safe, and why only certain formulas designed by IVP for drug discovery are efficacious in the prevention and treatment of senile cataract for long-term use. Overall cumulated studies demonstrate that the designed by IVP new vision-saving drug NAC eye drops help the aging eye to recover by improving its clarity, glare sensitivity, color perception and overall vision. PMID:19503764

  20. Developing a More Inclusive Curriculum: Revising Courses in Psychotherapy.

    ERIC Educational Resources Information Center

    Chambliss, Catherine

    In many respects clinical psychology has been more sensitive than most to issues related to gender, but many glaring problems remain to be addressed. In the clinical realm of psychology it is especially important to frame more inclusive conceptualizations of adjustment. Ursinus College developed a college-wide program aimed at greater integration…

  1. Bright ideas. Some rules of thumb for interior lighting design and selection.

    PubMed

    Hunter, Claudia M

    2002-07-01

    Interior lighting design and selection can be a demanding assignment for a health facilities manager or department head. It requires a balance between conflicting needs, such as providing good task lighting for a nursing station while also shielding luminaires that are visible from patients' rooms to avoid glare.

  2. The Academic and Social Adjustment of First Generation College Students

    ERIC Educational Resources Information Center

    Jean, Daniel

    2010-01-01

    First-generation college students face many issues that impede their progress within academia with the most glaring concern being they graduate at rates much lower than their counterparts. Further investigation revealed that fast-generation college students are more likely to dropout during their first-year with a high attrition rate during the…

  3. Concluding Commentary: Response to Eugene and Kiyo

    ERIC Educational Resources Information Center

    White, E. Jayne

    2014-01-01

    At the risk of speaking on his behalf I could almost swear I heard Bakhtin laughing gleefully over my shoulder as I read this fascinating dialogue between Eugene and Kiyo. His reason for this might be partly inspired by the glaring misunderstandings both men reveal through their associated interplay with key pedagogical concepts. While polemic in…

  4. The Call for Department Leaders.

    ERIC Educational Resources Information Center

    Gmelch, Walter H.

    This paper discusses development of the department chair, focusing on the need to build leadership capacity in colleges and universities. It suggests that it takes many years to become an expert, noting that one of the most glaring shortcomings in the leadership area is the scarcity of sound research on leadership training and development.…

  5. Special Topic: What's Worth Fighting against in Grading?

    ERIC Educational Resources Information Center

    Reeves, Douglas; Jung, Lee Ann; O'Connor, Ken

    2017-01-01

    Arguing that there is a "glaring" disconnect between recommended policy and actual practice in the area of grading, the authors outline four common grading practices that they say can impair instructional integrity and distort academic outcomes: 1) the use of the an average, or arithmetic mean, of performances to calculate a final grade;…

  6. Discovering Lewis and Clark

    ERIC Educational Resources Information Center

    Olsen, Ken

    2006-01-01

    Writer and historian Bernard DeVoto observed more than 50 years ago that a dismaying amount of American history has been written without regards to the Indians. Such disregard is glaring in many mainstream stories of Meriwether Lewis and William Clark. Lewis and Clark began preparing for their historic journey in 1803 and officially launched the…

  7. In Pursuit of a Computing Degree: Cultural Implications for American Indians

    ERIC Educational Resources Information Center

    Kodaseet, Glenda G.; Varma, Roli

    2012-01-01

    While a number of challenges contribute to the American Indian population's disconnect from information technology (IT), the most glaring is the low number of American Indian students pursuing computer science (CS) studies--a degree essential to IT's entry into and diffusion across communities. Yet, research is scant on factors that contribute to…

  8. [Surgical treatment with an artificial iris].

    PubMed

    Mayer, C S; Hoffmann, A E

    2015-10-01

    Iris defects with their disturbed pupillary function, visual impairment and glare constitute a therapeutic challenge in surgical reconstruction. A new therapeutic option for distinctive defects consists in the implantation of a custom-made silicone iris. This new and challenging therapy provides the opportunity to achieve an individual, aesthetically appealing and good functional result for the patient.

  9. Computer vision syndrome: a review.

    PubMed

    Blehm, Clayton; Vishnu, Seema; Khattak, Ashbala; Mitra, Shrabanee; Yee, Richard W

    2005-01-01

    As computers become part of our everyday life, more and more people are experiencing a variety of ocular symptoms related to computer use. These include eyestrain, tired eyes, irritation, redness, blurred vision, and double vision, collectively referred to as computer vision syndrome. This article describes both the characteristics and treatment modalities that are available at this time. Computer vision syndrome symptoms may be the cause of ocular (ocular-surface abnormalities or accommodative spasms) and/or extraocular (ergonomic) etiologies. However, the major contributor to computer vision syndrome symptoms by far appears to be dry eye. The visual effects of various display characteristics such as lighting, glare, display quality, refresh rates, and radiation are also discussed. Treatment requires a multidirectional approach combining ocular therapy with adjustment of the workstation. Proper lighting, anti-glare filters, ergonomic positioning of computer monitor and regular work breaks may help improve visual comfort. Lubricating eye drops and special computer glasses help relieve ocular surface-related symptoms. More work needs to be done to specifically define the processes that cause computer vision syndrome and to develop and improve effective treatments that successfully address these causes.

  10. Finite element modelling of aluminum alloy 2024-T3 under transverse impact loading

    NASA Astrophysics Data System (ADS)

    Abdullah, Ahmad Sufian; Kuntjoro, Wahyu; Yamin, A. F. M.

    2017-12-01

    Fiber metal laminate named GLARE is a new aerospace material which has great potential to be widely used in future lightweight aircraft. It consists of aluminum alloy 2024-T3 and glass-fiber reinforced laminate. In order to produce reliable finite element model of impact response or crashworthiness of structure made of GLARE, one can initially model and validate the finite element model of the impact response of its constituents separately. The objective of this study was to develop a reliable finite element model of aluminum alloy 2024-T3 under low velocity transverse impact loading using commercial software ABAQUS. Johnson-Cook plasticity and damage models were used to predict the alloy's material properties and impact behavior. The results of the finite element analysis were compared to the experiment that has similar material and impact conditions. Results showed good correlations in terms of impact forces, deformation and failure progressions which concluded that the finite element model of 2024-T3 aluminum alloy under low velocity transverse impact condition using Johnson-Cook plastic and damage models was reliable.

  11. A Theoretical Model for Estimation of Yield Strength of Fiber Metal Laminate

    NASA Astrophysics Data System (ADS)

    Bhat, Sunil; Nagesh, Suresh; Umesh, C. K.; Narayanan, S.

    2017-08-01

    The paper presents a theoretical model for estimation of yield strength of fiber metal laminate. Principles of elasticity and formulation of residual stress are employed to determine the stress state in metal layer of the laminate that is found to be higher than the stress applied over the laminate resulting in reduced yield strength of the laminate in comparison with that of the metal layer. The model is tested over 4A-3/2 Glare laminate comprising three thin aerospace 2014-T6 aluminum alloy layers alternately bonded adhesively with two prepregs, each prepreg built up of three uni-directional glass fiber layers laid in longitudinal and transverse directions. Laminates with prepregs of E-Glass and S-Glass fibers are investigated separately under uni-axial tension. Yield strengths of both the Glare variants are found to be less than that of aluminum alloy with use of S-Glass fiber resulting in higher laminate yield strength than with the use of E-Glass fiber. Results from finite element analysis and tensile tests conducted over the laminates substantiate the theoretical model.

  12. Ultrasonic Assessment of Impact-Induced Damage and Microcracking in Polymer Matrix Composites

    NASA Technical Reports Server (NTRS)

    Gyekanyesi, John (Technical Monitor); Liaw, Benjamin; Villars, Esther; Delmont, Frantz

    2003-01-01

    The main objective of this NASA Faculty Awards for Research (FAR) project is to conduct ultrasonic assessment of impact-induced damage and microcracking in fiber-metal laminated (FML) composites at various temperatures. It is believed that the proposed study of impact damage assessment on FML composites will benefit several NASA's missions and current interests, such as ballistic impact testing of composite fan containment and high strain rate deformation modeling of polymer matrix composites. Impact-induced damage mechanisms in GLARE and ARALL fiber-metal laminates subject to instrumented drop-weight impacts at various temperatures were studied. GLARE and ARALL are hybrid composites made of alternating layers of aluminum and glass- (for GLARE) and aramid- (for ARALL) fiber reinforced epoxy. Damage in pure aluminum panels impacted by foreign objects was mainly characterized by large plastic deformation surrounding a deep penetration dent. On the other hand, plastic deformation in fiber-metal laminates was often not as severe although the penetration dent was still produced. The more stiff fiber-reinforced epoxy layers provided better bending rigidity; thus, enhancing impact damage tolerance. Severe cracking, however, occurred due to the use of these more brittle fiber-reinforced epoxy layers. Fracture patterns, e.g., crack length and delamination size, were greatly affected by the lay-up configuration rather than by the number of layers, which implies that thickness effect was not significant for the panels tested in this study. Immersion ultrasound techniques were then used to assess damages generated by instrumented drop-weight impacts onto these fiber-metal laminate panels as well as 2024-T3 aluminum/cast acrylic sandwich plates adhered by epoxy. Depending on several parameters, such as impact velocity, mass, temperature, laminate configuration, sandwich construction, etc., various types of impact damage were observed, including plastic deformation, radiating cracks emanating from the impact site, ring cracks surrounding the impact site, partial and full delamination, and combinations of these damages.

  13. Ultrasonic Assessment of Impact-Induced Damage and Microcracking in Polymer Matrix Composites

    NASA Technical Reports Server (NTRS)

    Liaw, Benjamin; Villars, Esther; Delmont, Frantz; Bowles, Kenneth J. (Technical Monitor)

    2001-01-01

    The main objective of this NASA FAR project is to conduct ultrasonic assessment of impact-induced damage and microcracking in polymer matrix composites at various temperatures. It is believed that the proposed study of impact damage assessment on polymer matrix composites will benefit several NASA missions and current interests, such as ballistic impact testing of composite fan containment and high strain rate deformation modeling of polymer matrix composites. Impact-induced damage mechanisms in GLARE and ARALL fiber-metal laminates subject to instrumented drop-weight impacts at various temperatures were studied. GLARE and ARALL are hybrid composites made of alternating layers of aluminum and glass (for GLARE) and aramid- (for ARALL) fiber-reinforced epoxy. Damage in pure aluminum panels impacted by foreign objects was mainly characterized by large plastic deformation surrounding a deep penetration dent. On the other hand, plastic deformation in fiber-metal laminates was often not as severe although the penetration dent was still produced. The more stiff fiber-reinforced epoxy layers provided better bending rigidity; thus, enhancing impact damage tolerance. Severe cracking, however, occurred due to the use of these more brittle fiber-reinforced epoxy layers. Fracture patterns, e.g., crack length and delamination size, were greatly affected by the lay-up configuration rather than by the number of layers, which implies that thickness effect was not significant for the panels tested in this study. Immersion ultrasound techniques were then used to assess damages generated by instrumented drop-weight impacts onto these fiber-metal laminate panels as well as 6061-T6 aluminum/cast acrylic sandwich plates adhered by epoxy. Depending on several parameters, such as impact velocity, mass, temperature, laminate configuration, sandwich construction, etc., various types of impact damage were observed, including plastic deformation, radiating cracks emanating from the impact site, ring cracks surrounding the impact site, partial and full delamination, and combinations of these damages.

  14. [Management of post-traumatic aphakia and aniridia: Retrospective study of 17 patients undergoing scleral-sutured artificial iris intraocular lens implantation. Management of aphakia-aniridia with scleral-sutured artificial iris intraocular lenses].

    PubMed

    Villemont, A-S; Kocaba, V; Janin-Manificat, H; Abouaf, L; Poli, M; Marty, A-S; Rabilloud, M; Fleury, J; Burillon, C

    2017-09-01

    To evaluate the long-term outcomes of artificial iris intraocular lenses sutured to the sclera for managing traumatic aphakia and aniridia. All consecutive cases receiving a Morcher ® combination implant from June 2008 to February 2016 in Edouard-Herriot Hospital (Lyon, France) were included in this single-center retrospective study. Visual acuity, subjective degree of glare, quality of life and surgical complications were evaluated. Seventeen eyes of 17 patients were included, among which 82% were male. The mean age was 42 years. The injuries consisted of 23.5% contusion and 70.5% open globe injuries, of which 41% were globe ruptures. There was one postoperative case. A penetrating keratoplasty was performed at the same time for eight eyes. The mean follow-up was 32 months. Best-corrected visual acuity improved in 41.2%, remained the same in 17.6% and decreased in 41.2% of our cases. Distance vision averaged 1±0.25 line better and near vision 2.2±0.32 lines better when visual acuity was quantifiable before surgery. Glare improved in 80% of patients and remained stable in 20%, decreasing on average from 3.3/5 [min. 3-max. 4; SD: 0.48] before surgery to 1.9/5 [min. 0-max. 4; SD: 1.197] after surgery. Regarding the esthetic results, 78% of the patients declared themselves reasonably to very satisfied; 57% reported no limitation of activities of daily living, and 43% reported mild limitation. Ocular hypertension and glaucoma, found in 40% of eyes, were the main postoperative complications. Implantation of prosthetic iris device combined with an intraocular lens appears to be safe and effective in reducing glare disability and improving visual acuity. Close, long-term monitoring is essential for the success of this surgery. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. The Impact of Supplemental Antioxidants on Visual Function in Nonadvanced Age-Related Macular Degeneration: A Head-to-Head Randomized Clinical Trial.

    PubMed

    Akuffo, Kwadwo Owusu; Beatty, Stephen; Peto, Tunde; Stack, Jim; Stringham, Jim; Kelly, David; Leung, Irene; Corcoran, Laura; Nolan, John M

    2017-10-01

    The purpose of this study was to evaluate the impact of supplemental macular carotenoids (including versus not including meso-zeaxanthin) in combination with coantioxidants on visual function in patients with nonadvanced age-related macular degeneration. In this study, 121 participants were randomly assigned to group 1 (Age-Related Eye Disease Study 2 formulation with a low dose [25 mg] of zinc and an addition of 10 mg meso-zeaxanthin; n = 60) or group 2 (Age-Related Eye Disease Study 2 formulation with a low dose [25 mg] of zinc; n = 61). Visual function was assessed using best-corrected visual acuity, contrast sensitivity (CS), glare disability, retinal straylight, photostress recovery time, reading performance, and the National Eye Institute Visual Function Questionnaire-25. Macular pigment was measured using customized heterochromatic flicker photometry. There was a statistically significant improvement in the primary outcome measure (letter CS at 6 cycles per degree [6 cpd]) over time (P = 0.013), and this observed improvement was statistically comparable between interventions (P = 0.881). Statistically significant improvements in several secondary outcome visual function measures (letter CS at 1.2 and 2.4 cpd; mesopic and photopic CS at all spatial frequencies; mesopic glare disability at 1.5, 3, and 6 cpd; photopic glare disability at 1.5, 3, 6, and 12 cpd; photostress recovery time; retinal straylight; mean and maximum reading speed) were also observed over time (P < 0.05, for all), and were statistically comparable between interventions (P > 0.05, for all). Statistically significant increases in macular pigment at all eccentricities were observed over time (P < 0.0005, for all), and the degree of augmentation was statistically comparable between interventions (P > 0.05). Antioxidant supplementation in patients with nonadvanced age-related macular degeneration results in significant increases in macular pigment and improvements in CS and other measures of visual function. (Clinical trial, http://www.isrctn.com/ISRCTN13894787).

  16. Gender in the Classroom: Foundations, Skills, Methods, and Strategies Across the Curriculum

    ERIC Educational Resources Information Center

    Sadker, David, Ed.; Silber, Ellen S., Ed.

    2007-01-01

    According to research studies, one glaring omission from teacher education programs is gender. Tomorrow's teachers receive little instruction or training on the tremendous impact of gender in the classroom. Just how does gender influence teaching, the curriculum, and the lives of teachers and students in the classroom? This unique book has been…

  17. Garbage In, Garbage Out: Having Useful Data Is Everything

    ERIC Educational Resources Information Center

    Rose, L. Todd; Fischer, Kurt W.

    2011-01-01

    The focus article by Coburn and Turner (this issue) seeks to provide a comprehensive framework for understanding data use in the context of data-use interventions. This commentary focuses on what the authors see as a glaring omission in what is otherwise a valuable framework: the issue of "useful data." It is their contention that the usefulness…

  18. Glass Walls in North America. Technical Paper No. 179.

    ERIC Educational Resources Information Center

    Hutcheon, N. B.

    Solar heat gains (radiation) and its effects on the building environment are discussed, in conjunction with the proper and improper use of large glass areas in the exterior walls of buildings in North America. The difficulties of solar heat gain and of controlling natural light and glare are outlined and said to influence building comfort and air…

  19. Alice in Oman: A Study on Object-First Approaches in Computer Science Education

    ERIC Educational Resources Information Center

    Hayat, Khizar; Al-Shukaili, Naeem Ali; Sultan, Khalid

    2017-01-01

    The success of university-level education depends on the quality of underlying school education and any deficiency therein may be detrimental to a student's career. This may be more glaring with Computer Science education, given its mercurial nature. In the developing countries, the Computer Science school curricula are usually stuffed with…

  20. An Education Track for Creativity and Other Quality Thinking Processes

    ERIC Educational Resources Information Center

    Bleedorn, Berenice

    2003-01-01

    The need for new thinking in the world, both official leadership and for all participating members of society has been a glaring reality in recent times. To Berenice Bleedorn, the idea of teaching students how to use the full potential of their thinking apparatus is not absurd--simply logical and timely. Creative expression is central to the…

  1. Toward Development of a Generalized Instrument to Measure Andragogy

    ERIC Educational Resources Information Center

    Holton, Elwood F., III; Wilson, Lynda Swanson; Bates, Reid A.

    2009-01-01

    Andragogy has emerged as one of the dominant frameworks for teaching adults during the past 40 years. A major and glaring gap in andragogy research is the lack of a measurement instrument that adequately measures both andragogical principles and process design elements. As a result, no definitive empirical test of the theory has been possible. The…

  2. Family in the Public Eye

    ERIC Educational Resources Information Center

    Carr, Sarah E.

    2012-01-01

    Superintendents know they work and live in a giant fishbowl. School board members, teachers, community members and the news media have been known to scrutinize what kind of vehicle they drive, who they socialize with outside of work, whether they drink alcohol, where they live and when they leave the house each morning. But when the harsh glare of…

  3. Teaching about Haiti

    ERIC Educational Resources Information Center

    Sokolower, Jody

    2010-01-01

    For a few harrowing weeks in January, the eyes of the world were on Haiti, struggling with the impact of a 7.0 magnitude earthquake. In the spotlight's glare, people saw the devastation wrought by the natural disaster. Viewers with a critical eye or access to alternative media also saw a U.S. military presence more focused on security than food…

  4. Dangerous Omissions: Abstinence-Only-until-Marriage School-Based Sexuality Education and the Betrayal of LGBTQ Youth

    ERIC Educational Resources Information Center

    Elia, John P.; Eliason, Mickey J.

    2010-01-01

    To gain an understanding of how abstinence-only-until-marriage school-based sexuality education has been exclusionary, it is important to explore how heteronormativity has been endorsed, played out, and reproduced ever since school-based sexuality education has been offered in the United States. Such an exploration reveals glaring evidence that…

  5. Assessing Motivation to Read: The Motivation to Read Profile-Revised

    ERIC Educational Resources Information Center

    Malloy, Jacquelynn A.; Marinak, Barbara A.; Gambrell, Linda B.; Mazzoni, Susan A.

    2014-01-01

    For most classroom teachers, recognizing when students are engaged in literacy activities--and perhaps more glaringly, when they are not--is a process that is key to evaluating the potential success of the instruction being offered. Students who are engaged have their eyes on what they are doing, are ardently attending to the teacher's read aloud…

  6. Glare-reducing goggles for lookouts.

    Treesearch

    Richard E. McArdle; William G. Morris; Thornton T. Munger

    1936-01-01

    Detection of forest fires while they are still small is so important in forest protection that studies of the visibility of forest fire smokes from lookout points has been one of the principal phases of the fire studies program of the Pacific Northwest Forest Experiment Station. One phase of fire detection is the personal efficiency of the lookout. The Station has...

  7. Speaking the Language of Today's Digital Natives

    ERIC Educational Resources Information Center

    Neibling, John

    2010-01-01

    While most college presidents have mastered many basic tools of the digital environment, such as e-mail, Internet browsing, text messaging, most of them have yet to figure out social media--a glaring omission that remains one of the clearest dividing lines between generations young and old. Though most of them have yet to fully embrace social…

  8. 42 CFR 37.50 - Interpreting and classifying chest roentgenograms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 37.50 Section 37.50 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Office, 1750 New York Avenue, NW., Washington, DC 20006 (Phone: 202/376-2315). (d) In all view boxes used... kept clean; (4) The unit shall be so situated as to minimize front surface glare. [43 FR 33715, Aug. 1...

  9. "To Balance the Picture": Peace Activists and the Struggle for Equal Access in Chicago Schools, 1980-1985

    ERIC Educational Resources Information Center

    Kershner, Seth

    2014-01-01

    For more than forty years, parents, teachers, veterans, and community activists have engaged in grassroots resistance to the military's presence in schools. The historical study of campaigns against militarism in schools remains underdeveloped. This is a glaring omission, given the breadth and history of this activism. Militarism in the…

  10. Keeping Older Adults with Vision Loss Safe: Chronic Conditions and Comorbidities that Influence Functional Mobility

    ERIC Educational Resources Information Center

    Riddering, Anne T.

    2008-01-01

    Age-related macular degeneration (AMD) is a leading cause of vision loss in Americans aged 60 and older. The loss of central vision from AMD can decrease visual acuity, contrast sensitivity, glare sensitivity, color discrimination, and the ability to adapt to changes in lighting conditions. Older adults with vision loss often have other chronic,…

  11. Emergency Management Span of Control: Optimizing Organizational Structures to Better Prepare Vermont for the Next Major or Catastrophic Disaster

    DTIC Science & Technology

    2008-12-01

    full glare of media and public scrutiny, they are expected to perform flawlessly like a goalie in hockey or soccer, or a conversion kicker in...among all levels of government, not a plan that is pulled off the shelf only during worst- case disasters. The lifecycle of disasters entails a

  12. Enhancing Recruitment and Retention of Volunteers in the U.S. Coast Guard Auxiliary

    DTIC Science & Technology

    2008-12-01

    Boomers, Generation X, and Generation Y ( Millennials ), opt to continue working or pursue volunteer efforts with other volunteer organizations.180...parliamentary system Predominant Religion Christianity Judaism Predominant Language English Hebrew Sponsoring Agency U.S. Coast Guard – Military Israel...sustainable, effective, and well-trained membership. However, the glaring differences in geography, religion , culture, language, historical

  13. I Feel, Therefore, I Learn: The Role of Emotion in Self-Directed Learning

    ERIC Educational Resources Information Center

    Rager, Kathleen B.

    2009-01-01

    It is rare to find the emotional component of self-directed learning discussed explicitly in the literature. This lack is particularly glaring given the interest sparked by recent brain research concerning the importance of emotion in all types of learning as well as by the dramatic increase in self-directed learning in the emotionally charged…

  14. 77 FR 40843 - Federal Motor Vehicle Safety Standard No. 108; Lamp, Reflective Devices, and Associated Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-11

    ... limiting the impacts of glare. Our current standard primarily treats a headlamp as a separate piece of...) at any time by going to http://www.regulations.gov . Follow the online instructions for accessing the dockets. You may also read the materials at the Docket Management Facility by going to the street address...

  15. Report to Congress on Sustainable Ranges, 2015

    DTIC Science & Technology

    2015-03-01

    obstruction concerns related to height of wind turbines and/or associated infrastructure (power/transmission lines) and glint and glare concerns caused by...boundaries. This is particularly evident when the Doppler Effect from wind turbines located outside of the range boundary degrades critical... turbines , and will establish High Risk of Adverse Impact Zones (HRAIZ) to inform wind energy developers of possible conflicts. Electronic Combat (EC

  16. Gender Discrimination in Employment: Wage Inequity for Professional and Doctoral Degree Holders in the United States and Possible Remedies

    ERIC Educational Resources Information Center

    Wolford, Karen M.

    2005-01-01

    Gender discrimination and wage inequity remain problems worldwide. In the United States and Canada, where equal rights and protective legislation have been in place for nearly 40 years, glaring disparities in salaries and job opportunities remain. Similar problems have been studied in the United Kingdom, leading to enactment of the 1975 Sex…

  17. Solving the "Rural School Problem": New State Aid, Standards, and Supervision of Local Schools, 1900-1933

    ERIC Educational Resources Information Center

    Steffes, Tracy L.

    2008-01-01

    In 1918, Minnesota county superintendent Julius Arp argued that the greatest educational problem facing the American people was the Rural School Problem, saying: "There is no defect more glaring today than the inequality that exists between the educational facilities of the urban and rural communities. Rural education in the United States has…

  18. Review of Efforts to Develop a Low-Luminance-Level Disability Glare Tester

    DTIC Science & Technology

    2009-09-01

    figures 1. LASIK and PRK refractive surgery. .......................................................................................... 6  2...inadequate at this time, particularly for post refractive surgery patients. Early LASIK and PRK produced a very high incidence of night vision...1999). They found that before PRK or LASER in-situ keratomileusis ( LASIK ), simulated pupil dilation from 3 to 7 mm caused a 5-6 fold increase in

  19. Notes from the (Battle)field for Equity in Education

    ERIC Educational Resources Information Center

    Murtadha, Khaula

    2009-01-01

    There is a growing public awareness of the national drop-out crisis, but it does not, in the author's view, tell the whole story. It does not call attention to the fact that the most glaring need for new teachers and principals is in high-poverty areas where teaching conditions are the most challenging and where official public support has often…

  20. A Guide to the Librarian's Responsibility in Achieving Quality in Lighting and Ventilation.

    ERIC Educational Resources Information Center

    Mason, Ellsworth

    1967-01-01

    Quality, not intensity, is the keystone to good library lighting. The single most important problem in lighting is glare caused by extremely intense centers of light. Multiple interfiling of light rays is a factor required in library lighting. A fixture that diffuses light well is basic when light emerges from the fixture. It scatters widely,…

  1. Astronaut Carl Walz during EVA in Discovery's payload bay

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Astronaut Carl E. Walz reaches for equipment from the provisional stowage assembly (PSA) in Discvoery's cargo bay during a lengthy period of extravehicular activity (EVA). The hatch to Discovery's airlock is open nearby. Sun glare is evident above the orbiter. The picture was taken with a 35mm camera by astronaut James H. Newman, who shared EVA duties with Walz.

  2. Illuminating Engineering Research Institute Annual Report 1966. A Review of Research Activities and a View of New Goals in a Luminous Environment.

    ERIC Educational Resources Information Center

    Illuminating Engineering Research Inst., New York, NY.

    Several of the more familiar Illuminating Engineering Research Institute projects which have been chronicled progressively during the past several years are discussed in this report. Those elaborated on are--(1) visual performance and illumination, (2) roadway visual tasks, (3) color preference studies, (4) glare from large sources, (5) discomfort…

  3. The Development and Validation of the Transition Competence Battery for Adolescents and Young Adults with Deafness.

    ERIC Educational Resources Information Center

    Reiman, John; Bullis, Michael

    1988-01-01

    The lack of appropriate assessment tools designed for deaf adolescents and young adults making the transition from educational programs to adult life is cited as one of the most glaring deficits in the field of deafness. The Transition Competence Battery (TCB) is being developed as an assessment tool that will guide individual training decisions…

  4. Distorting the Historical Record: One Detailed Example from the Albert Shanker Institute's Report

    ERIC Educational Resources Information Center

    American Educator, 2012

    2012-01-01

    This article presents a detailed example from the Albert Shanker Institute's report that shows the error of U.S. history textbooks and how it is distorting the historical record. One of the most glaring errors in textbooks is the treatment of the role that unions and labor activists played as key participants in the civil rights movement. The…

  5. Resolution Properties Of A Computed Radiographic System

    NASA Astrophysics Data System (ADS)

    Fujita, Hiroshi; Morishita, Junji; Ueda, Katsuhiko; Tsai, Du Y.; Ohtsuka, Akiyoshi; Fujikawa, Tsuyoshi

    1989-05-01

    The analysis of spatial-resolution properties in terms of the modulation transfer function (MTF) has been presented in a computed radiographic (CR) system (FCR-101) with the photostimulable-phosphor plate (imaging plate, IP). The newly devised method of determining the presampling MTF which includes the x-ray detector (IP) unsharpness and the unsharpness of the sampling aperture is described in which an image of a slightly-angulated lead slit relative to a horizontal or vertical direction is employed. The IP MTFs as an analog MTF in the system, the presampling MTFs for different types of IPs, different sampling distances, different versions of IPs, simultaneous multisection tomography and magnification radiography, and the laser-printer MTFs as display MTF are measured and shown. The effective sampling aperture MTFs calculated indicate that the noticeable degradation of resolution occurs at the stage of image data sampling. The usefulness of the magnification technique for mammography and bone radiography is demonstrated. It is shown that both of the digital MTF and the overall MTF are difficult to use for general purpose due to the aliasing artifacts. The effect of glare on the contrast is also characterized by lead-disk method. The glare fraction is found to be approximately 6.5%.

  6. Effects on Training Using Illumination in Virtual Environments

    NASA Technical Reports Server (NTRS)

    Maida, James C.; Novak, M. S. Jennifer; Mueller, Kristian

    1999-01-01

    Camera based tasks are commonly performed during orbital operations, and orbital lighting conditions, such as high contrast shadowing and glare, are a factor in performance. Computer based training using virtual environments is a common tool used to make and keep CTW members proficient. If computer based training included some of these harsh lighting conditions, would the crew increase their proficiency? The project goal was to determine whether computer based training increases proficiency if one trains for a camera based task using computer generated virtual environments with enhanced lighting conditions such as shadows and glare rather than color shaded computer images normally used in simulators. Previous experiments were conducted using a two degree of freedom docking system. Test subjects had to align a boresight camera using a hand controller with one axis of rotation and one axis of rotation. Two sets of subjects were trained on two computer simulations using computer generated virtual environments, one with lighting, and one without. Results revealed that when subjects were constrained by time and accuracy, those who trained with simulated lighting conditions performed significantly better than those who did not. To reinforce these results for speed and accuracy, the task complexity was increased.

  7. Revisiting Resident Assistant Burnout: Functions of Gender, Community Composition, Choice to Continue Employment, and Job Satisfaction

    ERIC Educational Resources Information Center

    Stoner, James C.

    2017-01-01

    Research on resident assistant burnout peaked in the 1980s, and there has been little scholarship since. Much of the original literature is dated, and some contains unresolved conflicts in the findings. Also, there is a glaring gap in the literature, specifically in how burnout relates to both RA job satisfaction and position departure. This study…

  8. Expeditionary Lighting Systems for Military Shelters

    DTIC Science & Technology

    2009-11-04

    Lumiled LED Housing Nonimaging Beamformer Heat Sink Connector Retractable Cable O Transportation Configuration Physical Optics Corporation (POC) LED...New Lighting Technologies: • Technology: Light Emitting Diode (LED) o Physical Optics Corp [SBIR] o Techshot [SBIR] [Congressional Effort o Jameson LED...rugged and durable—no lamp to damage or replace • Custom designed optical diffuser prevents glare and “eye spots” • Operates on universal voltage, 90

  9. Top Five Large-Scale Solar Myths | State, Local, and Tribal Governments |

    Science.gov Websites

    of large-scale photovoltaic (PV) facilities or solar farms tend to include a myriad of misperceptions technologies do use mirrors which can cause glare, most solar farms use PV modules to generate electricity. PV panels in order to convert solar energy into electricity. PV modules are generally less reflective than

  10. Computational Modeling Basis in the Photostress Recovery Model (PREMO)

    DTIC Science & Technology

    2014-09-01

    classes of filters, for radial frequency selectivity and for orientation selectivity. Our current implementation accounts for the radial frequency...glare function and its attribution to the components of ocular scatter. Chairman’s Report CIE TC 1-18, Commission de l’Eclairage. 14. Watson, A...radiometric to photometric units to account for the differential spectral sensitivity of the eye. The spectral luminosity function for photopic vision is

  11. Reach Higher, America: Overcoming Crisis in the U.S. Workforce. Report of the National Commission on Adult Literacy

    ERIC Educational Resources Information Center

    National Commission on Adult Literacy (NJ1), 2008

    2008-01-01

    Education drives the economy. Almost a decade into the 21st Century, America faces a choice: It can invest in the basic education and skills of its workforce and remain competitive in today's global economy, or it can continue to overlook glaring evidence of a national crisis and move further down the path to decline. In this report, the National…

  12. The Aviation Accident Experience of Civilian Airmen With Refractive Surgery

    DTIC Science & Technology

    2002-06-01

    such as photorefractive keratec- tomy (PRK) and laser-assisted in situ keratomileusis ( LASIK ), are being performed on a rapidly growing number of...stable, healing is complete, and no glare intolerance is present (4). RK, PRK, and LASIK procedures are similar only in that the goal is to improve...called photoablation, which utilizes the excimer laser to vaporize the cornea’s outer tissue. LASIK uses a specially designed surgical scalpel

  13. 2005 Tri-Service Infrastructure Systems Conference and Exhibition. Volume 12. Tracks 15, 16 and 17

    DTIC Science & Technology

    2005-08-04

    glare, surface luminances, and uniformity. Also, the importance of daylight on human health and productivity is emphasized. • Exterior lighting design...Electrical Safety Requirements – OSHA CFR Title 29 Part 1910 Occupational Safety and Health Standard, Subpart S – Electrical – Design Safety...Standards and Safety Related Work Practices Part 1926 Safety and Health Regulations for Construction, Subpart K – Electrical – Installation Safety

  14. Better Schools through Better Politics: The Human Side of Portfolio School District Reform. Portfolio School Districts Project

    ERIC Educational Resources Information Center

    Sperry, Sam

    2012-01-01

    From the Center on Reinventing Public Education's (CRPE's) work examining the efforts to close schools over the past 10 years, in cities of all sizes, two glaring facts stand out: Most city and district leaders are surprised at how difficult it is to close schools. And many of these leaders make mistakes that others before them have learned to…

  15. Low Vision Aids in Glaucoma

    PubMed Central

    Khanna, Anjani

    2012-01-01

    A large number of glaucoma patients suffer from vision impairments that qualify as low vision. Additional difficulties associated with low vision include problems with glare, lighting, and contrast, which can make daily activities extremely challenging. This article elaborates on how low vision aids can help with various tasks that visually impaired glaucoma patients need to do each day, to take care of themselves and to lead an independent life. PMID:27990068

  16. The visual standards for the selection and retention of astronauts, part 2

    NASA Technical Reports Server (NTRS)

    Allen, M. J.; Levene, J. R.; Heath, G. G.

    1972-01-01

    In preparation for the various studies planned for assessing visual capabilities and tasks in order to set vision standards for astronauts, the following pieces of equipment have been assembled and tested: a spectacle obstruction measuring device, a biometric glare susceptibility tester, a variable vergence amplitude testing device, an eye movement recorder, a lunar illumination simulation chamber, a night myopia testing apparatus, and retinal adaption measuring devices.

  17. Scatter and veiling glare corrections for quantitative digital subtraction angiography

    NASA Astrophysics Data System (ADS)

    Ersahin, Atila; Molloi, Sabee Y.; Qian, Yao-Jin

    1994-05-01

    In order to quantitate anatomical and physiological parameters such as vessel dimensions and volumetric blood flow, it is necessary to make corrections for scatter and veiling glare (SVG), which are the major sources of nonlinearities in videodensitometric digital subtraction angiography (DSA). A convolution filtering technique has been investigated to estimate SVG distribution in DSA images without the need to sample the SVG for each patient. This technique utilizes exposure parameters and image gray levels to estimate SVG intensity by predicting the total thickness for every pixel in the image. At this point, corrections were also made for variation of SVG fraction with beam energy and field size. To test its ability to estimate SVG intensity, the correction technique was applied to images of a Lucite step phantom, anthropomorphic chest phantom, head phantom, and animal models at different thicknesses, projections, and beam energies. The root-mean-square (rms) percentage error of these estimates were obtained by comparison with direct SVG measurements made behind a lead strip. The average rms percentage errors in the SVG estimate for the 25 phantom studies and for the 17 animal studies were 6.22% and 7.96%, respectively. These results indicate that the SVG intensity can be estimated for a wide range of thicknesses, projections, and beam energies.

  18. Iridoplasty of fixed-dilated pupil (Urrets-Zavalia syndrome) after deep anterior lamellar keratoplasty

    PubMed Central

    Ntora, Efthalia; Ziakas, Nikolaos

    2017-01-01

    A 38-year-old woman with advanced keratoconus initially developed Urrets-Zavalia Syndrome (UZS) in the left eye after deep anterior lamellar keratoplasty. During the uneventful surgery, a 7-mm-wide pupil unresponsive to light was noticed. On the first postoperative day, intraocular pressure (IOP) was elevated up to 45 mmHg with shallow anterior chamber (AC). A peripheral iridotomy in 2 o’clock position was conducted and a fixed combination of brinzolamide 1% and timolol 0.5% was administered topically. In the subsequent postoperative period, IOP was successfully reduced, but the patient reported severe photophobia, glare, and decreased vision. Twelve months after surgery, her best-corrected visual acuity (BCVA) was 20/200, the fixed-dilated pupil persisted, iris was atrophic, and lens opacities were detected. She was submitted for phacoemulsification cataract surgery combined with iridoplasty using the closed chamber slipping suture technique. Three months after surgery, her BCVA was 20/25, pupil diameter remained stable at 4 mm, and glare symptoms were significantly reduced. A very adequate cosmetic outcome was also achieved. Iridoplasty in postkeratoplasty patient with unilateral UZS was effective in improving patient's visual function disability and restoring residual anisocoria. This technique can be applied as a single procedure or combined with another one for the management of UZS. PMID:29118500

  19. Dynamics of backlight luminance for using smartphone in dark environment

    NASA Astrophysics Data System (ADS)

    Na, Nooree; Jang, Jiho; Suk, Hyeon-Jeong

    2014-02-01

    This study developed dynamic backlight luminance, which gradually changes as time passes for comfortable use of a smartphone display in a dark environment. The study was carried out in two stages. In the first stage, a user test was conducted to identify the optimal luminance by assessing the facial squint level, subjective glare evaluation, eye blink frequency and users' subjective preferences. Based on the results of the user test, the dynamics of backlight luminance was designed. It has two levels of luminance: the optimal level for initial viewing to avoid sudden glare or fatigue to users' eyes, and the optimal level for constant viewing, which is comfortable, but also bright enough for constant reading of the displayed material. The luminance for initial viewing starts from 10 cd/m2, and it gradually increases to 40 cd/m2 for users' visual comfort at constant viewing for 20 seconds; In the second stage, a validation test on dynamics of backlight luminance was conducted to verify the effectiveness of the developed dynamics. It involving users' subjective preferences, eye blink frequency, and brainwave analysis using the electroencephalogram (EEG) to confirm that the proposed dynamic backlighting enhances users' visual comfort and visual cognition, particularly for using smartphones in a dark environment.

  20. Planets to Cosmology

    NASA Astrophysics Data System (ADS)

    Livio, Mario; Casertano, Stefano

    2011-11-01

    Preface; 1. Hubble's view of transiting planets D. Charbonneau; 2. Unsolved problems in star formation C. J. Clarke; 3. Star formation in clusters S. S. Larson; 4. HST abundance studies of low metallicity stars J. W. Truran, C. Sneden, F. Primas, J. J. Cowan and T. Beers; 5. Physical environments and feedback: HST studies of intense star-forming environments J. S. Gallagher, L. J. Smith and R. W. O'Connell; 6. Quasar hosts: growing up with monstrous middles K. K. McLeod; 7. Reverberation mapping of active galactic nuclei B. M. Peterson and K. Horne; 8. Feedback at high redshift A. E. Shapley; 9. The baryon content of the local intergalactic medium J. T. Stocke, J. M. Shull, and S. V. Penton; 10. Hot baryons in supercluster filaments E. D. Miller, R. A. Dupke and J. N. Bregman; 11. Galaxy assembly E. F. Bell; 12. Probing the reionization history of the Universe Z. Haiman; 13. Studying distant infrared-luminous galaxies with Spitzer and Hubble C. Papovich, E. Egami, E. Le Floc'h, P. Pérez-González, G. Rieke, J. Rigby, H. Dole and M. Reike; 14. Galaxies at z = g-i'-drop selection and the GLARE Project E. R. Stanway, K. Glazebrook, A. J. Bunker and the GLARE Consortium; 15. The Hubble Ultra Deep Field with NIMCOS R. I. Thompson, R. J. Bouwens and G. Illingworth.

  1. Planets to Cosmology

    NASA Astrophysics Data System (ADS)

    Livio, Mario; Casertano, Stefano

    2006-04-01

    Preface; 1. Hubble's view of transiting planets D. Charbonneau; 2. Unsolved problems in star formation C. J. Clarke; 3. Star formation in clusters S. S. Larson; 4. HST abundance studies of low metallicity stars J. W. Truran, C. Sneden, F. Primas, J. J. Cowan and T. Beers; 5. Physical environments and feedback: HST studies of intense star-forming environments J. S. Gallagher, L. J. Smith and R. W. O'Connell; 6. Quasar hosts: growing up with monstrous middles K. K. McLeod; 7. Reverberation mapping of active galactic nuclei B. M. Peterson and K. Horne; 8. Feedback at high redshift A. E. Shapley; 9. The baryon content of the local intergalactic medium J. T. Stocke, J. M. Shull, and S. V. Penton; 10. Hot baryons in supercluster filaments E. D. Miller, R. A. Dupke and J. N. Bregman; 11. Galaxy assembly E. F. Bell; 12. Probing the reionization history of the Universe Z. Haiman; 13. Studying distant infrared-luminous galaxies with Spitzer and Hubble C. Papovich, E. Egami, E. Le Floc'h, P. Pérez-González, G. Rieke, J. Rigby, H. Dole and M. Reike; 14. Galaxies at z = g-i'-drop selection and the GLARE Project E. R. Stanway, K. Glazebrook, A. J. Bunker and the GLARE Consortium; 15. The Hubble Ultra Deep Field with NIMCOS R. I. Thompson, R. J. Bouwens and G. Illingworth.

  2. Eyeglass Filters

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Biomedical Optical Company of America's suntiger lenses eliminate more than 99% of harmful light wavelengths. NASA derived lenses make scenes more vivid in color and also increase the wearer's visual acuity. Distant objects, even on hazy days, appear crisp and clear; mountains seem closer, glare is greatly reduced, clouds stand out. Daytime use protects the retina from bleaching in bright light, thus improving night vision. Filtering helps prevent a variety of eye disorders, in particular cataracts and age related macular degeneration.

  3. KSC-03PP-2099

    NASA Technical Reports Server (NTRS)

    2003-01-01

    KENNEDY SPACE CENTER, FLA. NASA launches its second Mars Exploration Rover, Opportunity, aboard a Delta II launch vehicle. The bright glare briefly illuminated Florida Space Coast beaches. Opportunitys dash to Mars began with liftoff at 11:18:15 p.m. Eastern Daylight Time from Cape Canaveral Air Force Station, Fla. The spacecraft separated successfully from the Delta's third stage 83 minutes later, after it had been boosted out of Earth orbit and onto a course toward Mars.

  4. Sequential lift and suture technique for post-LASIK corneal striae.

    PubMed

    Mackool, Richard J; Monsanto, Vivian R

    2003-04-01

    We describe a surgical technique to manage persistent corneal striae after laser in situ keratomileusis (LASIK). The sequential lift and suture technique reduces the time required for LASIK, eliminates the need to fixate the flap with forceps during suturing, and increases the accuracy of suture placement. The results in 10 eyes (9 patients) showed complete resolution of striae with improvement in subjective symptoms (glare and blurred vision) and best corrected visual acuity.

  5. Mobile Tactical HF/VHF/EW System for Ground Forces

    DTIC Science & Technology

    1989-09-01

    presen- tation of what I have learned . I would like to thank my advisor, Professor Robert Partelow, and co-advisor, Commander James R. Powell, for the...analyze newly developed systems to determine how the man- machine interfaces of such systems can best be designed for optimal use by the operators. B...terminals and other controls. If factors like luminance ratio, reflectance, glare illuminance are allowed for good man- machine interface then an effective

  6. Lying to Ourselves: Dishonesty in the Army Profession

    DTIC Science & Technology

    2015-02-01

    nature of land warfare; • Matters affecting the Army’s future; • The concepts, philosophy, and theory of strategy; and, • Other issues of importance...morally wrong behavior into socially acceptable conduct by dimming the glare and guilt of the ethical spotlight. One factor that encourages ethical...placating the Army bureaucracy or civilian overseers by telling them what they want to hear. As a result, Army leaders learn to talk of one world

  7. Demonstration Program for Low-Cost, High-Energy-Saving Dynamic Windows

    DTIC Science & Technology

    2014-09-01

    Design The scope of this project was to demonstrate the impact of dynamic windows via energy savings and HVAC peak-load reduction; to validate the...temperature and glare. While the installed dynamic window system does not directly control the HVAC or lighting of the facility, those systems are designed ...optimize energy efficiency and HVAC load management. The conversion to inoperable windows caused an unforeseen reluctance to accept the design and

  8. Differences in vision between clinic and home and the effect of lighting in older adults with and without glaucoma

    PubMed Central

    Bhorade, Anjali M.; Perlmutter, Monica S.; Wilson, Brad; Kambarian, Jamie; Chang, Sidney; Pekmezci, Melike; Gordon, Mae

    2015-01-01

    Importance Patients often report greater visual difficulties at home than expected from vision testing in the clinic. Such discordance may be due to worse vision in the home than measured in clinic. Objective To compare vision measured between clinic and home and evaluate factors, including lighting, associated with these differences. Design Cross-sectional, between years 2005–2009. Setting Participants recruited from the Glaucoma and Comprehensive Eye Clinics at Washington University, St. Louis, MO underwent a clinic and home visit. Participants 126 glaucoma and 49 non-glaucoma patients, ages 55–90 years, consecutively recruited and met inclusion criteria for this report; 166 eligible patients refused participation. Exposure Participants underwent a clinic and home visit randomized to order of completion. At each visit, masked and certified examiners measured binocular distance visual acuity (DVA) with a non-backlit chart, near visual acuity (NVA), contrast sensitivity (CS), CS with glare, and lighting. Main Outcome Measure Differences in vision between clinic and home. Results Mean scores for all vision tests were significantly better in the clinic than home for glaucoma and non-glaucoma patients (p<0.05, matched pair t-tests). For DVA, 29% of glaucoma participants read ≥2 lines better in clinic than home and 39% with advanced glaucoma read ≥3 lines better. For the entire sample, 21% of participants read ≥2 lines better in clinic than home for NVA and 49% read ≥2 triplets better in clinic for CS with glare. Lighting was the most significant factor associated with differences in vision between clinic and home for DVA, NVA, and CS with glare testing (p<0.05 multiple regression model). Median home lighting was 4.3 times and 2.8 times lower than clinic lighting in areas tested for DVA and NVA, respectively. Home lighting was below that recommended in ≥ 85% of participants. Conclusions and Relevance Vision measured in the clinic is generally better than vision measured at home, with differences mainly due to poor home lighting. Knowledge that vision discrepancies between patient report and clinical testing may be due to home lighting may initiate clinician-patient discussions to increase home lighting and improve vision of older adults in their homes. PMID:24263699

  9. High-fidelity artifact correction for cone-beam CT imaging of the brain

    NASA Astrophysics Data System (ADS)

    Sisniega, A.; Zbijewski, W.; Xu, J.; Dang, H.; Stayman, J. W.; Yorkston, J.; Aygun, N.; Koliatsos, V.; Siewerdsen, J. H.

    2015-02-01

    CT is the frontline imaging modality for diagnosis of acute traumatic brain injury (TBI), involving the detection of fresh blood in the brain (contrast of 30-50 HU, detail size down to 1 mm) in a non-contrast-enhanced exam. A dedicated point-of-care imaging system based on cone-beam CT (CBCT) could benefit early detection of TBI and improve direction to appropriate therapy. However, flat-panel detector (FPD) CBCT is challenged by artifacts that degrade contrast resolution and limit application in soft-tissue imaging. We present and evaluate a fairly comprehensive framework for artifact correction to enable soft-tissue brain imaging with FPD CBCT. The framework includes a fast Monte Carlo (MC)-based scatter estimation method complemented by corrections for detector lag, veiling glare, and beam hardening. The fast MC scatter estimation combines GPU acceleration, variance reduction, and simulation with a low number of photon histories and reduced number of projection angles (sparse MC) augmented by kernel de-noising to yield a runtime of ~4 min per scan. Scatter correction is combined with two-pass beam hardening correction. Detector lag correction is based on temporal deconvolution of the measured lag response function. The effects of detector veiling glare are reduced by deconvolution of the glare response function representing the long range tails of the detector point-spread function. The performance of the correction framework is quantified in experiments using a realistic head phantom on a testbench for FPD CBCT. Uncorrected reconstructions were non-diagnostic for soft-tissue imaging tasks in the brain. After processing with the artifact correction framework, image uniformity was substantially improved, and artifacts were reduced to a level that enabled visualization of ~3 mm simulated bleeds throughout the brain. Non-uniformity (cupping) was reduced by a factor of 5, and contrast of simulated bleeds was improved from ~7 to 49.7 HU, in good agreement with the nominal blood contrast of 50 HU. Although noise was amplified by the corrections, the contrast-to-noise ratio (CNR) of simulated bleeds was improved by nearly a factor of 3.5 (CNR = 0.54 without corrections and 1.91 after correction). The resulting image quality motivates further development and translation of the FPD-CBCT system for imaging of acute TBI.

  10. Damage Tolerant Repair Techniques for Pressurized Aircraft Fuselages

    DTIC Science & Technology

    1994-01-01

    2 if20 20 offset 50, fatigue GST, GLARE 2 if20 20 static, no fatigue *Unidirectional SP500 carbon/epoxy tape . "* Fatigue load did not initiate a crack...Et value, so this is a reasonable assumption. It further implies zero crack opening under the patch. The Erdogan solution [51 for two collinear...Cr Figure 6. 11. Idealization of patched crack as unfailed ligament between two collinear cracks (after [5, 6)). The Erdogan solution leads to the AK

  11. Damage Tolerant Repair Techniques for Pressurized Aircraft Fuselages

    DTIC Science & Technology

    1994-06-06

    crack patching effectiveness, long cracks ( Erdogan ) 186 Vii Acknowledgments My three years of Ph.D. work would have been impossible without the...fatigue GST, GLARE 2 " " 20 20 static, no fatigue *Unidirectional SP500 carbon/epoxy tape . *Fatigue load did not initiate a crack. The saw cut was...assurnption It further implies zero crack opening under the pat(:r The Erdogan solutior (51 for two Coiinear Ctacks can be expressed as: %A F -. " (621 F

  12. High-performance LED luminaire for sports hall

    NASA Astrophysics Data System (ADS)

    Lee, Xuan-Hao; Yang, Jin-Tsung; Chien, Wei-Ting; Chang, Jung-Hsuan; Lo, Yi-Chien; Lin, Che-Chu; Sun, Ching-Cherng

    2015-09-01

    In this paper, we present a luminaire design with anti-glare and energy-saving effects for sports hall. Compared with traditional lamps using in a badminton court, the average illuminance on the ground of the proposed LED luminaire is enhanced about 300%. Besides, the uniformity is obviously enhanced and improved. The switch-on speed of lighting in sports hall is greatly reduced from 5-10 minutes to 1 second. The simulation analysis and the corresponding experiment results are demonstrated.

  13. Congreve Rockets

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The British fired Congreve rockets against the United States in the War of 1812. As a result Francis Scott Key coined the phrase the 'rocket's red glare.' Congreve had used a 16-foot guide stick to help stabilize his rocket. William Hale, another British inventor, invented the stickless rocket in 1846. The U.S. Army used the Hale rocket more than 100 years ago in the war with Mexico. Rockets were also used to a limited extent by both sides in the American Civil War.

  14. Early Rockets

    NASA Image and Video Library

    2004-04-15

    The British fired Congreve rockets against the United States in the War of 1812. As a result Francis Scott Key coined the phrase the "rocket's red glare." Congreve had used a 16-foot guide stick to help stabilize his rocket. William Hale, another British inventor, invented the stickless rocket in 1846. The U.S. Army used the Hale rocket more than 100 years ago in the war with Mexico. Rockets were also used to a limited extent by both sides in the American Civil War.

  15. 23G pars plana vitrectomy for vitreal floaters: prospective assessment of subjective self-reported visual impairment and surgery-related risks during the course of treatment.

    PubMed

    Hahn, Ursula; Krummenauer, Frank; Ludwig, Klaus

    2018-06-01

    Quantifying the subjective impairment due to floaters based on an indication-specific questionnaire and setting its change between prior to and 3/12 months after elective vitrectomy in relation to surgical risks. Single-arm longitudinal observational multicenter study. Sixty-four floater patients underwent 23G pars plana vitrectomy; simultaneous phacoemulsification was excluded. An overall self-rated impairment index (SRI) and sub-indices SRI were calculated on the basis of a modified Visual Quality of Life questionnaire (VQoL), which addresses general vision, glare, near-sight problems and mobility of floaters. SRI ranged from 0 to 100% (maximum impairment). Secondary endpoints included corrected visual acuity and complications. Data were collected prior to and 3 (n = 64) and 12 (n = 62) months after surgery. The median overall SRI improved (44, 12, 11%) with a statistically significant median reduction of 69% (95% confidence interval 50-89%) 3 months postop. The median sub-SRIs improved for glare (50, 17, 17%), near sight problems (50, 17, 8%), and mobility of floaters (43, 5, 0%). Sixteen eyes needed cataract surgery during follow-up (10 showed cataract already prior to vitrectomy). Eight complications were reported (6 intra-operative retinal holes, 2 post-operative retinal detachments). For the majority of floater patients, subjective impairment was profoundly reduced by vitrectomy. Benefits of surgery prevailed despite complications.

  16. Through-Focus Vision Performance and Light Disturbances of 3 New Intraocular Lenses for Presbyopia Correction

    PubMed Central

    Escandón-García, Santiago; Ribeiro, Filomena J.; McAlinden, Colm

    2018-01-01

    Purpose To compare the through-focus visual performance in a clinical population of pseudophakic patients implanted with two new trifocal intraocular lenses (IOLs) and one extended depth of focus IOL. Methods Prospective, nonrandomized, examiner-masked case series. Twenty-three patients received the FineVision® and seven patients received the PanOptix™ trifocal IOLs. Fifteen patients received the Symfony extended depth of focus IOL. Mean age of patients was 63 ± 8 years. Through-focus visual acuity was measured from –3.00 to +1.00 D vergences. Contrast sensitivity was measured with and without a source of glare. Light disturbances were evaluated with the Light Distortion Analyzer. Results Though-focus evaluation showed that trifocal IOLs performed significantly better at near distance (33 and 40 cm), and extended depth of focus performed significantly better at intermediate distance (1.0 m). Contrast sensitivity function with glare and dysphotopsia was similar between the three IOLs and subjective response to questionnaire showed a significantly higher score (worse performance) for the extended depth of focus IOL compared to both trifocal IOLs in the bothersome subscale (p < 0.05). Conclusions Trifocal IOLs grant better performance at near distance while extended depth of focus IOL performs better at intermediate distance. Objective dysphotopsia measured with the Light Distortion Analyzer is not reduced in extended depth of focus IOL compared to trifocal IOLs. PMID:29651343

  17. Visual function of police officers who have undergone refractive surgery.

    PubMed

    Hovis, Jeffery K; Ramaswamy, Shankaran

    2006-11-01

    The visual acuity and contrast sensitivity of police recruits and officers was evaluated in both normal and dim illumination conditions to determine whether officers who have had refractive surgery have compromised night vision. The control group consisted of 76 officers and recruits who have not had refractive surgery and the refractive surgery group consisted of 22 officers and recruits who had refractive surgery. Visual acuity and contrast sensitivity were measured under both room illumination and dim illumination. The room illumination test series included high contrast acuity, low contrast acuity and Pelli-Robson contrast sensitivity. The dim illumination test series included high contrast acuity, low contrast acuity, Pelli-Robson contrast sensitivity, license plate number acuity (with and without glare) and the Mesotest. The general findings were that the refractive surgery group had lower acuity scores on low contrast targets in both room and dim light levels along with a reduction in the Mesotest scores with a glare source compared to the control group. Although refractive surgery police recruits and officers had reduced performance on some vision tests, these reductions were small and it is unlikely that their performance on vision related tasks would be compromised, on average. The major concern is the small number of refractive surgery candidates whose results were well outside the range of the non-surgical candidates. Their vision may be unacceptable for policing. Copyright (c) 2006 Wiley-Liss, Inc.

  18. High order aberration and straylight evaluation after cataract surgery with implantation of an aspheric, aberration correcting monofocal intraocular lens

    PubMed Central

    Kretz, Florian T A; Tandogan, Tamer; Khoramnia, Ramin; Auffarth, Gerd U

    2015-01-01

    AIM To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting, monofocal intraocular lens (IOL). METHODS Twenty-one patients (34 eyes) aged 50 to 83y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL (Tecnis ZCB00, Abbott Medical Optics). Three months after surgery they were examined for uncorrected (UDVA) and corrected distance visual acuity (CDVA), contrast sensitivity (CS) under photopic and mesopic conditions with and without glare source, ocular high order aberrations (HOA, Zywave II) and retinal straylight (C-Quant). RESULTS Postoperatively, patients achieved a postoperative CDVA of 0.0 logMAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27 (primary coma components) and -0.04±0.16 (spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed (P≥0.28). CONCLUSION The implantation of an aspherical aberration correcting monofocal IOL after cataract surgery resulted in very low residual higher order aberration (HOA) and normal straylight. PMID:26309872

  19. Development of Photographic Dynamic Measurements Applicable to Evaluation of Flapping Wing Micro Air Vehicles

    DTIC Science & Technology

    2011-12-01

    deformation is passive, because there are no control muscles to actively change the wing shape[2].   2    1.2 The Problem The overall...properly under flapping conditions to generate lift. This is key because the insect lacks muscles to actively change the wing shape[2]. For a...millimeters with the origin at the center of the left camera. During these tests, there was still glare off the carbon fiber , although it did not obscure

  20. Community participatory research with deaf sign language users to identify health inequities.

    PubMed

    Barnett, Steven; Klein, Jonathan D; Pollard, Robert Q; Samar, Vincent; Schlehofer, Deirdre; Starr, Matthew; Sutter, Erika; Yang, Hongmei; Pearson, Thomas A

    2011-12-01

    Deaf people who use American Sign Language (ASL) are medically underserved and often excluded from health research and surveillance. We used a community participatory approach to develop and administer an ASL-accessible health survey. We identified deaf community strengths (e.g., a low prevalence of current smokers) and 3 glaring health inequities: obesity, partner violence, and suicide. This collaborative work represents the first time a deaf community has used its own data to identify health priorities.

  1. Community Participatory Research With Deaf Sign Language Users to Identify Health Inequities

    PubMed Central

    Barnett, Steven; Klein, Jonathan D.; Pollard, Robert Q.; Samar, Vincent; Schlehofer, Deirdre; Starr, Matthew; Sutter, Erika; Yang, Hongmei

    2011-01-01

    Deaf people who use American Sign Language (ASL) are medically underserved and often excluded from health research and surveillance. We used a community participatory approach to develop and administer an ASL-accessible health survey. We identified deaf community strengths (e.g., a low prevalence of current smokers) and 3 glaring health inequities: obesity, partner violence, and suicide. This collaborative work represents the first time a deaf community has used its own data to identify health priorities. PMID:22021296

  2. The Neuroergonomics of Vigilance: Effects of Spatial Uncertainty on Cerebral Blood Flow Velocity and Oculomotor Fatigue

    DTIC Science & Technology

    2017-02-01

    in studies of this sort. One goal for the present study was to test the expectation, based on resource theory, that because of the higher...VDT was mounted on a table 99.10 cm directly in front of the seated observer (visual angle = 23.54°). Ambient illumination in the testing room (5...minimize glare on the VDT. To curb distraction, observers were separated from the TCD equipment by a cubicle wall dividing the width of the testing

  3. Wofford-Thornburgh: a turning point for health reform.

    PubMed

    Tokarski, C

    1992-01-01

    The November 5 special election in Pennsylvania pitting appointed Senator Harris Wofford against former U.S. Attorney General Richard Thornburgh was a turning point in the national debate over health reform. Under the glare of media spotlights, Wofford mounted a come-from-behind victory over the heavily favored Thornburgh by trumpeting "national health insurance." Since Wofford's victory, President Bush has rethought his previous indifference to health reform and promised to announce a comprehensive plan in January, more than a year ahead of schedule.

  4. Fiber Metal Laminates Made by the VARTM Process

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Cano, Roberto J.; Hales, Stephen J.; Alexa, Joel A.; Weiser, Erik S.; Loos, Alfred; Johnson, W.S.

    2009-01-01

    Fiber metal laminates (FMLs) are multi-component materials utilizing metals, fibers and matrix resins. Tailoring their properties is readily achievable by varying one or more of these components. Established FMLs like GLARE utilize aluminum foils, glass fibers and epoxy matrices and are manufactured using an autoclave. Two new processes for manufacturing FMLs using vacuum assisted resin transfer molding (VARTM) have been developed at the NASA Langley Research Center (LaRC). A description of these processes and the resulting FMLs are presented.

  5. Cold Regions Environmental Test of Nuclear, Biological, and Chemical Decontamination Equipment

    DTIC Science & Technology

    1985-05-17

    Blowing Snow "Rain Wet Fog Hail "Falling snow Ice Fog Other (specify) Malfunctions (explain): Remarks: A-1 -. , -17 May 1985 TOP 8-4-007 SAPPENDIX S...displays. * ~4. Remove and replace minor items [) FI FI[ * ( lightbulbs , filters, etc.) 5. Lubricate. ii F ) C 6. Add expendables. (I FJ( * ~~7...Displays are readable under dark [1 [1 [ . :I to bright glare conditions. 21. Cover glass does hot fog up. [ [ [. [E 22. Displays do not freeze up

  6. It's Time for an Ambitious National Investment in America's Children: Investments in Early Childhood Care and Education Would Have Enormous Benefits for Children, Families, Society, and the Economy

    ERIC Educational Resources Information Center

    Bivens, Josh; García, Emma; Gould, Elise; Weiss, Elaine; Wilson, Valerie

    2016-01-01

    Nearly 7 years into the recovery from the Great Recession, two glaring problems remain in the U.S. economy. One is a significant slowdown in the growth of productivity (the amount of output and income generated in an average hour of work). The other is the destructive rise in income inequality in recent decades due largely to big corporations and…

  7. Minute of physics

    NASA Astrophysics Data System (ADS)

    Page, Katie

    2011-05-01

    It's 7:23 a.m. sometime last fall, students are running through the halls to get to class, and as I stand in my doorway greeting kids, I notice that only about 2/3 of my students are seated and ready to go. 7:24…7:25, the final bell rings. As the next few minutes roll past, students continue to stroll in with a glare from me. I decided to try something new to get students to class on time, and, after some research, the "Minute of Physics" was born.

  8. Solar Energy Systems

    NASA Astrophysics Data System (ADS)

    1984-01-01

    Calibrated in kilowatt hours per square meter, the solar counter produced by Dodge Products, Inc. provides a numerical count of the solar energy that has accumulated on a surface. Solar energy sensing, measuring and recording devices in corporate solar cell technology developed by Lewis Research Center. Customers for their various devices include architects, engineers and others engaged in construction and operation of solar energy facilities; manufacturers of solar systems or solar related products, such as glare reducing windows; and solar energy planners in federal and state government agencies.

  9. Fixed Wing Performance. Theory and Flight Test Techniques

    DTIC Science & Technology

    1977-07-01

    L , J JA , iii hit I.IbS*I u Se t UX 1-4, Xl -4 TEST PROCEDURES AND TECHTNIUE,_ Pertinent Particulars a. At the time these tests are performed, the...7 , - • • . • • • • ••: • - • • -V• ,• • • • . . . REFERENCES Section XV 1. Anthropometry of Naval Aviators, 1964, NAEC-ACEL--533. 2. Cockpit...glare shlelds, etc. Htuman e~gineering persokmet are prepared to se particuiar equipments to attain quarititative data in cockpi’ anthropometry N NOT

  10. Optical And Environmental Properties Of NCAP Glazing Products

    NASA Astrophysics Data System (ADS)

    van Konynenburg, Peter; Wipfler, Richard T.; Smith, Jerry L.

    1989-07-01

    The first large area, commercially available, electrically-controllable glazing products sold under the tradename VARILITETM are based on a new liquid crystal film technology called NCAP. The glazing products can be switched in milliseconds between a highly translucent state (for privacy and glare control) to a transparent state (for high visibility) with the application of an AC voltage. The optical and environmental properties are demonstrated to meet the general requirements for architectural glazing use. The first qualified indoor product is described in detail.

  11. Energy Saving in Electric Lighting for the United States Army.

    DTIC Science & Technology

    1979-10-05

    these reasons. Avoid devices such as power saving buttons which are to be placed in the sockets of incandescent bulbs. They are merely half-wave...using the button or a long-life bulb. Another device to avoid is the pulse or transient suppressor. This device, essentially a voltage clipper...arranged In a geo- metric pattern. It is used to shield a lamp from Lumen: A unit of light output from a lamp. view at certain angles to avoid glare from

  12. LDEF grappled by remote manipulator system (RMS) during STS-32 retrieval

    NASA Image and Video Library

    1990-01-20

    This view taken through overhead window W7 on Columbia's, Orbiter Vehicle (OV) 102's, aft flight deck shows the Long Duration Exposure Facility (LDEF) in the grasp of the remote manipulator system (RMS) during STS-32 retrieval activities. Other cameras at eye level were documenting the bus-sized spacecraft at various angles as the RMS manipulated LDEF for a lengthy photo survey. The glaring celestial body in the upper left is the sun with the Earth's surface visible below.

  13. Optical countermeasures against CLOS weapon systems

    NASA Astrophysics Data System (ADS)

    Toet, Alexander; Benoist, Koen W.; van Lingen, Joost N. J.; Schleijpen, H. Ric M. A.

    2013-10-01

    There are many weapon systems in which a human operator acquires a target, tracks it and designates it. Optical countermeasures against this type of systems deny the operator the possibility to fulfill this visual task. We describe the different effects that result from stimulation of the human visual system with high intensity (visible) light, and the associated potential operational impact. Of practical use are flash blindness, where an intense flash of light produces a temporary "blind-spot" in (part of) the visual field, flicker distraction, where strong intensity and/or color changes at a discomfortable frequency are produced, and disability glare where a source of light leads to contrast reduction. Hence there are three possibilities to disrupt the visual task of an operator with optical countermeasures such as flares or lasers or a combination of these; namely, by an intense flash of light, by an annoying light flicker or by a glare source. A variety of flares for this purpose is now available or under development: high intensity flash flares, continuous burning flares or strobe flares which have an oscillating intensity. The use of flare arrays seems particularly promising as an optical countermeasure. Lasers are particularly suited to interfere with human vision, because they can easily be varied in intensity, color and size, but they have to be directed at the (human) target, and issues like pointing and eye-safety have to be taken into account. Here we discuss the design issues and the operational impact of optical countermeasures against human operators.

  14. Extracting and shaping the light of OLED devices

    NASA Astrophysics Data System (ADS)

    Riedel, Daniel; Dlugosch, Julian; Wehlus, Thomas; Brabec, Christoph

    2015-09-01

    Before the market entry of organic light emitting diodes (OLEDs) into the field of general illumination can occur, limitations in lifetime, luminous efficacy and cost must be overcome. Additional requirements for OLEDs used for general illumination may be imposed by workplace glare reduction requirements, which demand limited luminance for high viewing angles. These requirements contrast with the typical lambertian emission characteristics of OLEDs, which result in the same luminance levels for all emission angles. As a consequence, without additional measures glare reduction could limit the maximum possible luminance of lambertian OLEDs to relatively low levels. However, high luminance levels are still desirable in order to obtain high light output. We are presenting solutions to overcome this dilemma. Therefore this work is focused on light-shaping structures for OLEDs with an internal light extraction layer. Simulations of beam-shaping structures and shapes are presented, followed by experimental measurements to verify the simulations of the most promising structures. An investigation of the loss channels has been carried out and the overall optical system efficiency was evaluated for all structures. The most promising light shaping structures achieve system efficiencies up to 80%. Finally, a general illumination application scenario has been simulated. The number of OLEDs needed to illuminate an office room has been deduced from this scenario. By using light-shaping structures for OLEDs, the number of OLEDs needed to reach the mandatory illuminance level for a workplace environment can be reduced to one third compared to lambertian OLEDs.

  15. Measured daylighting potential of a static optical louver system under real sun and sky conditions

    DOE PAGES

    Konis, Kyle; Lee, Eleanor S.

    2015-05-04

    Side-by-side comparisons were made over solstice-to-solstice changes in sun and sky conditions between an optical louver system (OLS) and a conventional Venetian blind set at a horizontal slat angle and located inboard of a south-facing, small-area, clerestory window in a full-scale office testbed. Daylight autonomy (DA), window luminance, and ceiling luminance uniformity were used to assess performance. The performance of both systems was found to have significant seasonal variation, where performance under clear sky conditions improved as maximum solar altitude angles transitioned from solstice to equinox. Although the OLS produced fewer hours per day of DA on average than themore » Venetian blind, the OLS never exceeded the designated 2000 cd/m2 threshold for window glare. In contrast, the Venetian blind was found to exceed the visual discomfort threshold over a large fraction of the day during equinox conditions. Notably, these peak periods of visual discomfort occurred during the best periods of daylighting performance. Luminance uniformity was analyzed using calibrated high dynamic range luminance images. Under clear sky conditions, the OLS was found to increase the luminance of the ceiling as well as produce a more uniform distribution. Furthermore, compared to conventional venetian blinds, the static optical sunlight redirecting system studied has the potential to significantly reduce the annual electrical lighting energy demand of a daylit space and improve the quality from the perspective of building occupants by consistently transmitting useful daylight while eliminating window glare.« less

  16. Standardisation of DNA quantitation by image analysis: quality control of instrumentation.

    PubMed

    Puech, M; Giroud, F

    1999-05-01

    DNA image analysis is frequently performed in clinical practice as a prognostic tool and to improve diagnosis. The precision of prognosis and diagnosis depends on the accuracy of analysis and particularly on the quality of image analysis systems. It has been reported that image analysis systems used for DNA quantification differ widely in their characteristics (Thunissen et al.: Cytometry 27: 21-25, 1997). This induces inter-laboratory variations when the same sample is analysed in different laboratories. In microscopic image analysis, the principal instrumentation errors arise from the optical and electronic parts of systems. They bring about problems of instability, non-linearity, and shading and glare phenomena. The aim of this study is to establish tools and standardised quality control procedures for microscopic image analysis systems. Specific reference standard slides have been developed to control instability, non-linearity, shading and glare phenomena and segmentation efficiency. Some systems have been controlled with these tools and these quality control procedures. Interpretation criteria and accuracy limits of these quality control procedures are proposed according to the conclusions of a European project called PRESS project (Prototype Reference Standard Slide). Beyond these limits, tested image analysis systems are not qualified to realise precise DNA analysis. The different procedures presented in this work determine if an image analysis system is qualified to deliver sufficiently precise DNA measurements for cancer case analysis. If the controlled systems are beyond the defined limits, some recommendations are given to find a solution to the problem.

  17. Static Properties of Fibre Metal Laminates

    NASA Astrophysics Data System (ADS)

    Hagenbeek, M.; van Hengel, C.; Bosker, O. J.; Vermeeren, C. A. J. R.

    2003-07-01

    In this article a brief overview of the static properties of Fibre Metal Laminates is given. Starting with the stress-strain relation, an effective calculation tool for uniaxial stress-strain curves is given. The method is valid for all Glare types. The Norris failure model is described in combination with a Metal Volume Fraction approach leading to a useful tool to predict allowable blunt notch strength. The Volume Fraction approach is also useful in the case of the shear yield strength of Fibre Metal Laminates. With the use of the Iosipescu test shear yield properties are measured.

  18. Optical design of tunnel lighting with white light-emitting diodes.

    PubMed

    Tsai, Ming-Shiou; Lee, Xuan-Hao; Lo, Yi-Chien; Sun, Ching-Cherng

    2014-10-10

    This paper presents a tunnel lighting design consisting of a cluster light-emitting diode and a free-form lens. Most of the energy emitted from the proposed luminaire is transmitted onto the surface of the road in front of drivers, and the probability that that energy is emitted directly into drivers' eyes is low. Compared with traditional fluorescent lamps, the proposed luminaire, of which the optical utilization factor, optical efficiency, and uniformity are, respectively, 44%, 92.5%, and 0.72, exhibits favorable performance in energy saving, glare reduction, and traffic safety.

  19. The Forward Masking Effects of Low-Level Laser Glare on Target Location Performance in a Visual Search Task.

    DTIC Science & Technology

    1992-01-01

    Oxford University Press, NY, 1984. 24. Neisser , U ., Cognitive Psychology; Chap. 2, Prentice-Hall, Inc., Englewood Cliffs, NJ, 1967. 25. Enoch, J.M...in this study. (ýRA•,’&l AI IC TA U J Ia oiic ti .y ......... .......... ........ DTIC ~ZTL7 c ~T~DIBy Distribu fo. I "". ’.1’...•’.. - , . 1 ii •0... u -der low-ambient lighting conditions, visual search inside the cockpit on a CRT monitor mounted in the instrument panel is not disrupted by laser

  20. Subjective Visual Performance and Objective Optical Quality With Intraocular Lens Glistening and Surface Light Scattering.

    PubMed

    Luo, Furong; Bao, Xuan; Qin, Yingyan; Hou, Min; Wu, Mingxing

    2018-06-01

    To evaluate the long-term effect of glistenings and surface light scattering of intraocular lenses (IOLs) on visual and optical performance after cataract surgery. Pseudophakic eyes that underwent standard phacoemulsification and two types of hydrophobic acrylic spherical IOL implantation without complications for at least 5 years were included in this retrospective study. Participants were divided into the glistenings, surface light scattering, and control groups according to the current condition of the IOLs. Then participants received a follow-up examination including uncorrected and corrected distance visual acuity (UDVA and CDVA), contrast sensitivity, straylight, and intraocular higher order aberrations, as well as point spread function (PSF) and modulation transfer function (MTF). A total of 140 eyes were included in the study. UDVA, CDVA, and glare sensitivity were not significantly different among the three groups (P > .05). However, compared with the control group, the IOLs of the glistenings and surface light scattering groups were associated with significantly lower contrast sensitivity under no glare conditions. Furthermore, eye with glistenings exhibited the highest straylight value (P < .05), whereas no difference was found between the surface light scattering and control groups. In contrast to the control group, the spherical aberration increased and the mean values of PSF and MTF decreased in the glistenings and surface light scattering groups. Both glistenings and surface light scattering tend to impair subjective visual performance, such as contrast sensitivity, and potentially affect objective optical quality, including straylight, spherical aberration, PSF, and MTF. [J Refract Surg. 2018;34(6):372-378.]. Copyright 2018, SLACK Incorporated.

  1. An assessment of the performance and quality control procedures of PACS workstation monitors used in Irish radiology departments

    NASA Astrophysics Data System (ADS)

    Wade, Cherrie; Brennan, Patrick C.; Mc Entee, Mark F.

    2005-04-01

    Diagnostic efficacy in soft-copy reporting relies heavily on the quality of workstation monitors and an investigation performed in 2002 demonstrated that CRT monitors in Dublin imaging departments were not operating at optimal levels. The current work examines the performance of CRTs being used in Dublin and other parts of Ireland to establish if problems reported in the earlier work have been rectified. All hospitals performing soft-copy reporting for general radiology using CRTs were included in the work. Examination of ambient lighting, calibration of monitors and analysis of CRT performance using the SMPTE test pattern and a selection of the AAPM test images was performed. Maximum luminance, spatial uniformity of luminance, temporal luminance stability, gamma, geometry, sharpness, veiling glare and spatial resolution of each monitor was evaluated. Ambient lighting in all reporting areas was within recommended levels. All the monitors were calibrated appropriately and were performing at acceptable levels for maximum luminance and temporal stability and only one of the thirty-three investigated failed to reach the standard for spatial uniformity. In contrast a number of the CRTs investigated showed poor adherence to acceptable levels for geometrical distortions, veiling glare and spatial resolution all of which are important influencers of image quality. Gamma values also appeared to be low for a number of monitors but this interpretation is provisional and subject to the establishment of ratified guideline values. The results demonstrate that although some improvement on the previous situation is evident, greater adherence to acceptable levels is required for certain parameters.

  2. High incidence of rainbow glare after femtosecond laser assisted-LASIK using the upgraded FS200 femtosecond laser.

    PubMed

    Zhang, Yu; Chen, Yue-Guo

    2018-03-05

    To compare the incidence of rainbow glare (RG) after femtosecond laser assisted-LASIK (FS-LASIK) using the upgraded FS200 femtosecond laser with different flap cut parameter settings. A consecutive series of 129 patients (255 eyes) who underwent FS-LASIK for correcting myopia and/or astigmatism using upgraded WaveLight FS200 femtosecond laser with the original settings was included in group A. Another consecutive series of 129 patients (255 eyes) who underwent FS-LASIK using upgraded WaveLight FS200 femtosecond laser with flap cut parameter settings changed (decreased pulse energy, spot and line separation) was included in group B. The incidence and fading time of RG, confocal microscopic image and postoperative clinical results were compared between the two groups. There were no differences between the two groups in age, baseline refraction, excimer laser ablation depth, postoperative uncorrected visual acuity and refraction. The incidence rate of RG in group A (35/255, 13.73%) was significantly higher than that in group B (4/255, 1.57%) (P < 0.05). The median fading time was 3 months in group A and 1 month in group B (P > 0.05).The confocal microscopic images showed wider laser spot spacing in group A than group B. The incidence of RG was significantly correlated with age and grouping (P < 0.05). The upgraded FS200 femtosecond laser with original flap cut parameter settings could increase the incidence of RG. The narrower grating size and lower pulse energy could ameliorate this side effect.

  3. Corneal lenticular wrinkling after automated lamellar keratoplasty.

    PubMed

    Steinemann, T L; Denton, N C; Brown, M F

    1998-10-01

    To report complications of automated lamellar keratoplasty in two eyes of two patients. Case reports. Two eyes of two patients underwent automated lamellar keratoplasty for myopia. Both patients complained of visual distortion and glare in the postoperative eye. The postoperative eye of both patients showed evidence of wrinkling of the corneal lenticule accompanied by irregular astigmatism. Patient 1 showed persistent lenticular wrinkling and corneal scarring 2.5 years later. Patient 2 showed evidence of interface scar and overcorrection. The use of a microkeratome can be complicated by lenticular displacement and wrinkling, resulting in visual aberration for the patient.

  4. Statistical Energy Analysis for Designers. Part 1. Basic Theory

    DTIC Science & Technology

    1974-09-01

    deterministic system. That is a possible answer, but it may not be the most useful one. The most glaring deficiency of SEA is its inability to deal with...present whether this represents the "next logical step" in the chain that we spoke of, but it bears examination. 13 A second deficiency of SEA is its...undamped string, p = lineal density, r = 0, and A=-T(D/ax) 2. Thus, Eq. (2.3.2) becomes Tk2 = pw2, or k = ±w/c , (2.3.3) where c=VT- is the speed of

  5. Finding Sequences for over 270 Orphan Enzymes

    PubMed Central

    Shearer, Alexander G.; Altman, Tomer; Rhee, Christine D.

    2014-01-01

    Despite advances in sequencing technology, there are still significant numbers of well-characterized enzymatic activities for which there are no known associated sequences. These ‘orphan enzymes’ represent glaring holes in our biological understanding, and it is a top priority to reunite them with their coding sequences. Here we report a methodology for resolving orphan enzymes through a combination of database search and literature review. Using this method we were able to reconnect over 270 orphan enzymes with their corresponding sequence. This success points toward how we can systematically eliminate the remaining orphan enzymes and prevent the introduction of future orphan enzymes. PMID:24826896

  6. From conditional oughts to qualitative decision theory

    NASA Technical Reports Server (NTRS)

    Pearl, Judea

    1994-01-01

    The primary theme of this investigation is a decision theoretic account of conditional ought statements (e.g., 'You ought to do A, if C') that rectifies glaring deficiencies in classical deontic logic. The resulting account forms a sound basis for qualitative decision theory, thus providing a framework for qualitative planning under uncertainty. In particular, we show that adding causal relationships (in the form of a single graph) as part of an epistemic state is sufficient to facilitate the analysis of action sequences, their consequences, their interaction with observations, their expected utilities, and the synthesis of plans and strategies under uncertainty.

  7. History of Hubble Space Telescope (HST)

    NASA Image and Video Library

    1997-09-08

    This NASA Hubble Space Telescope (HST) image of the Trifid Nebula reveals a stellar nursery being torn apart by a nearby massive star. Embryonic stars are forming within an ill-fated cloud of dust and gas, which is destined to be eaten away by the glare from the massive neighbor. The cloud is about 8 light years away from the nebula' s central star. This stellar activity is a beautiful example of how the life cycle of stars like our Sun is intimately cornected with their more powerful siblings. Residing in the constellation Sagittarius, the Trifid Nebula is about 9,000 light years from Earth.

  8. [Design and optical principles of multifocal lenses].

    PubMed

    Auffarth, G U; Rabsilber, T M; Kohnen, T; Holzer, M P

    2008-06-01

    Multifocal intraocular lenses (MIOLs) of different designs have been used for more than 20 years in modern cataract surgery. The first IOLs were either refractive 2-3-zone designs or of diffractive concept. All MIOL types, regardless of manufacturer, show reduced contrast sensitivity and increased glare for years. Nevertheless, even first-generation MIOL patients had very good functional results when patient selection, IOL calculation, and surgical techniques were appropriate. Today's gold standard is foldable, aspherical diffractive, or refractive MIOLS. Advancements in technology allow the possibility that MIOLs will be used for aphakia correction as well as presbyopia correction.

  9. A Bright Idea for the Eyes

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The WEstinghouse Lighting Corporation's Eye Saver[TM] Easy Reading Light Bulb is the result of collaboration between Westinghouse, Marshall Research LLC, and NASA's Space Optics Manufacturing Technology Center at Marshall Space Flight Center. The light bulb contains a chrome top that directs light to areas where it is needed most. The bulb, which lasts 2,000 hours, provides 40 percent more surface illumination on work and reading surfaces, compared to a standard incandescent bulb. The lightly frosted finish reduces glare, which helps to reduce eyestrain. The bulb is particularly helpful for people with low vision and eye diseases such as macular degeneration.

  10. The Trifid Nebula

    NASA Technical Reports Server (NTRS)

    1997-01-01

    This NASA Hubble Space Telescope (HST) image of the Trifid Nebula reveals a stellar nursery being torn apart by a nearby massive star. Embryonic stars are forming within an ill-fated cloud of dust and gas, which is destined to be eaten away by the glare from the massive neighbor. The cloud is about 8 light years away from the nebula' s central star. This stellar activity is a beautiful example of how the life cycle of stars like our Sun is intimately cornected with their more powerful siblings. Residing in the constellation Sagittarius, the Trifid Nebula is about 9,000 light years from Earth.

  11. Review of Urinalysis Drug Testing Program. Report by a Panel of Army and Civilian Experts in Toxicology and Drug Testing Legal Issues for the Surgeon General of the U.S. Army

    DTIC Science & Technology

    1983-12-12

    the National Institute on Drug Abuse (NIDA). Dr. Simon is a consultant on forensic toxicology and currently is the Director of Industrial...THC ratio algorithm, and no laboratory has the personnel trained to provide forensic testimony on the THC or other drug GC/MS data. d. The GC/MS...adequate expertise to support GC/MS internally and forensically document (for courts-martial) GC/MS. The USAF Homestead AFB case is a glaring example of

  12. Colour vision experimental studies in teaching of optometry

    NASA Astrophysics Data System (ADS)

    Ozolinsh, Maris; Ikaunieks, Gatis; Fomins, Sergejs

    2005-10-01

    Following aspects related to human colour vision are included in experimental lessons for optometry students of University of Latvia. Characteristics of coloured stimuli (emitting and reflective), determination their coordinates in different colour spaces. Objective characteristics of transmitting of colour stimuli through the optical system of eye together with various types of appliances (lenses, prisms, Fresnel prisms). Psychophysical determination of mono- and polychromatic stimuli perception taking into account physiology of eye, retinal colour photoreceptor topography and spectral sensitivity, spatial and temporal characteristics of retinal receptive fields. Ergonomics of visual perception, influence of illumination and glare effects, testing of colour vision deficiencies.

  13. Accurate color measurement methods for medical displays.

    PubMed

    Saha, Anindita; Kelley, Edward F; Badano, Aldo

    2010-01-01

    The necessity for standard instrumentation and measurements of color that are repeatable and reproducible is the major motivation behind this work. Currently, different instrumentation and methods can yield very different results when measuring the same feature such as color uniformity or color difference. As color increasingly comes into play in medical imaging diagnostics, display color will have to be quantified in order to assess whether the display should be used for imaging purposes. The authors report on the characterization of three novel probes for measuring display color with minimal contamination from screen areas outside the measurement spot or from off-normal emissions. They compare three probe designs: A modified small-spot luminance probe and two conic probe designs based on black frusta. To compare the three color probe designs, spectral and luminance measurements were taken with specialized instrumentation to determine the luminance changes and color separation abilities of the probes. The probes were characterized with a scanning slit method, veiling glare, and a moving laser and LED arrangement. The scanning slit measurement was done using a black slit plate over a white line on an LCD monitor. The luminance was measured in 1 mm increments from the center of the slit to +/- 15 mm above and below the slit at different distances between the probe and the slit. The veiling glare setup consisted of measurements of the luminance of a black spot pattern with a white disk of radius of 100 mm as the black spot increases in 1 mm radius increments. The moving LED and laser method consisted of a red and green light orthogonal to the probe tip for the light to directly shine into the probe. The green light source was moved away from the red source in 1 cm increments to measure color stray-light contamination at different probe distances. The results of the color testing using the LED and laser methods suggest a better performance of one of the frusta probes at shorter distances between the light sources, which translates to less contamination. The tails of the scans indicate the magnitude of the spread in signal due to light from areas outside the intended measurement spot. The measurements indicate a corresponding glare factor for a large spot of 140, 500, and 2000 for probe A, B1, and B2, respectively. The dual-laser setup suggests that color purity can be maintained up to a few tens of millimeters outside the measurement spot. The comparison shows that there are significant differences in the performance of each probe design, and that those differences have an effect on the measured quantity used to quantify display color. Different probe designs show different measurements of the level of light contamination that affects the quantitative color determination.

  14. [The Influence of risk factors on visual performance in of phototoxic maculopathy in occupational welders].

    PubMed

    Li, Qingtao; Zhang, Xinfang

    2014-10-01

    To investigate the Influence of risk factors that cause the phototoxic maculopathy by welding arc in occupational welders. We examined randomly a group of 86 male occupational welders 172 eyes from some local metal manufacturing enterprise from August 2010 to December 2013. The ophthalmologic examination which the participants underwent thorough including the best visual acuity, fundus examination by the supplementary lens, fundus photography, and the high definition optical coherence tomography (OCT) scan. All participants of this study underwent thorough the medicine examined by a specialist of occupational who prior to the OCT. All the subjects were divided into groups according to age, protection degrees , length of service, operating time . The incidences of phototoxic maculopathy were compared within groups. The subjects was divided randomly into the lutein group and the placebo group. The examination including the best visual acuity, serum lutein concentrations, macular pigmentoptical density (MPOD), Contrast and glare Sensitivity. (1) The total incidence of phototoxic maculopathy is 32.0%. (2) The incidences of phototoxic maculopathy in the strict protection group, the randomed protective group and the nonprofessional protection group were respectively 21.4%, 36.7%, 53.6%. The incidence in the strict protection group was lower than the other two groups, the incidence was the highest in the nonprofessional protection group, and the difference was statistically significant. (3) The longer length of service, and operating time , the more incidence of phototoxic maculopathy develop. (4) The lutein group prior to the placebo group at the best visual acuity, serum lutein concentrations, macular pigmentoptical density (MPOD), Contrast and glare Sensitivity. The risk factors of phototoxic maculopathy in male occupational welders are the length of service, operating time, protection degrees and the lutein assistantly. The incidence of phototoxic maculopathy occurs regardless of age.

  15. Eye-related pain induced by visually demanding computer work.

    PubMed

    Thorud, Hanne-Mari Schiøtz; Helland, Magne; Aarås, Arne; Kvikstad, Tor Martin; Lindberg, Lars Göran; Horgen, Gunnar

    2012-04-01

    Eye strain during visually demanding computer work may include glare and increased squinting. The latter may be related to elevated tension in the orbicularis oculi muscle and development of muscle pain. The aim of the study was to investigate the development of discomfort symptoms in relation to muscle activity and muscle blood flow in the orbicularis oculi muscle during computer work with visual strain. A group of healthy young adults with normal vision was randomly selected. Eye-related symptoms were recorded during a 2-h working session on a laptop. The participants were exposed to visual stressors such as glare and small font. Muscle load and blood flow were measured by electromyography and photoplethysmography, respectively. During 2 h of visually demanding computer work, there was a significant increase in the following symptoms: eye-related pain and tiredness, blurred vision, itchiness, gritty eyes, photophobia, dry eyes, and tearing eyes. Muscle load in orbicularis oculi was significantly increased above baseline and stable at 1 to 1.5% maximal voluntary contraction during the working sessions. Orbicularis oculi muscle blood flow increased significantly during the first part of the working sessions before returning to baseline. There were significant positive correlations between eye-related tiredness and orbicularis oculi muscle load and eye-related pain and muscle blood flow. Subjects who developed eye-related pain showed elevated orbicularis oculi muscle blood flow during computer work, but no differences in muscle load, compared with subjects with minimal pain symptoms. Eyestrain during visually demanding computer work is related to the orbicularis oculi muscle. Muscle pain development during demanding, low-force exercise is associated with increased muscle blood flow, possible secondary to different muscle activity pattern, and/or increased mental stress level in subjects experiencing pain compared with subjects with minimal pain.

  16. An Evaluation of Performance Characteristics of Primary Display Devices.

    PubMed

    Ekpo, Ernest U; McEntee, Mark F

    2016-04-01

    The aim of this study was to complete a full evaluation of the new EIZO RX850 liquid crystal display and compare it to two currently used medical displays in Australia (EIZO GS510 and Barco MDCG 5121). The American Association of Physicists in Medicine (AAPM) Task Group 18 Quality Control test pattern was used to assess the performance of three high-resolution primary medical displays: EIZO RX850, EIZO GS510, and Barco MDCG 5121. A Konica Minolta spectroradiometer (CS-2000) was used to assess luminance response, non-uniformity, veiling glare, and color uniformity. Qualitative evaluation of noise was also performed. Seven breast lesions were displayed on each monitor and photographed with a calibrated 5.5-MP Olympus E-1 digital SLR camera. ImageJ software was used to sample pixel information from each lesion and surrounding background to calculate their conspicuity index on each of the displays. All monitor fulfilled all AAPM acceptance criteria. The performance characteristics for EIZO RX850, Barco MDCG 5121, and EIZO GS510 respectively were as follows: maximum luminance (490, 500.5, and 413 cd/m(2)), minimum luminance (0.724, 1.170, and 0.92 cd/m(2)), contrast ratio (675:1, 428:1, 449:1), just-noticeable difference index (635, 622, 609), non-uniformity (20, 5.92, and 8.5 %), veiling glare (GR = 2465.6, 720.4, 1249.8), and color uniformity (Δu'v' = +0.003, +0.002, +0.002). All monitors demonstrated low noise levels. The conspicuity index (χ) of the lesions was slightly higher in the EIZO RX850 display. All medical displays fulfilled AAPM performance criteria, and performance characteristics of EIZO RX850 are equal to or better than those of the Barco MDCG 5121 and EIZO GS510 displays.

  17. Development of a Physical Environmental Observational Tool for Dining Environments in Long-Term Care Settings.

    PubMed

    Chaudhury, Habib; Keller, Heather; Pfisterer, Kaylen; Hung, Lillian

    2017-11-10

    This paper presents the first standardized physical environmental assessment tool titled Dining Environment Audit Protocol (DEAP) specifically designed for dining spaces in care homes and reports the results of its psychometric properties. Items rated include: adequacy of lighting, glare, personal control, clutter, staff supervision support, restraint use, and seating arrangement option for social interaction. Two scales summarize the prior items and rate the overall homelikeness and functionality of the space. Ten dining rooms in three long-term care homes were selected for assessment. Data were collected over 11 days across 5 weeks. Two trained assessors completed DEAP independently on the same day. Interrater-reliability was completed for lighting, glare, space, homelike aspects, seating arrangements and the two summary scales, homelikeness and functionality of the space. For categorical measures, measure responses were dichotomized at logical points and Cohen's Kappa and concordance on ratings were determined. The two overall rating scales on homelikeness and functionality of space were found to be reliable intraclass correlation coefficient (ICC) (~0.7). The mean rating for homelikeness for Assessor 1 was 3.5 (SD 1.35) and for functionality of the room was 5.3. (SD 0.82; median 5.5). The findings indicate that the tool's interrater-reliability scores are promising. The high concordance on the overall scores for homelikeness and functionality is indicative of the strength of the individual items in generating a reliable global assessment score on these two important aspects of the dining space. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Assessment of subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL) implantation.

    PubMed

    Iijima, Ayaka; Shimizu, Kimiya; Yamagishi, Mayumi; Kobashi, Hidenaga; Igarashi, Akihito; Kamiya, Kazutaka

    2016-12-01

    To evaluate the subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL, STAAR Surgical) implantation. We prospectively examined 29 eyes of 29 consecutive patients (15 men and 14 women; ages, 37.2 ± 8.8 years) undergoing Hole ICL implantation. We assessed the values of the logarithmic straylight value [log (s)] using a straylight meter (C-Quant ™ , Oculus) preoperatively and 3 months postoperatively. The patients completed a questionnaire detailing symptoms on a quantitative grading scale (National Eye Institute Refractive Error Quality of Life Instrument-42; NEI RQL-42) 3 months postoperatively. We compared the preoperative and postoperative values of the log(s) and evaluated the correlation of these values with patient subjective symptoms. The mean log(s) was not significantly changed, from 1.07 ± 0.20 preoperatively, to 1.06 ± 0.17 postoperatively (Wilcoxon signed-rank test, p = 0.641). There was a significant correlation between the preoperative and postoperative log(s) (Spearman's correlation coefficient r = 0.695, p < 0.001). The postoperative log(s) was significantly associated with the scores of glare in the questionnaire (Spearman's correlation coefficient r = -0.575, p = 0.017). According to our experience, Hole ICL implantation does not induce a significant additional change in the subjective intraocular forward scattering. The symptom of glare after Hole ICL implantation was significantly correlated with the postoperative intraocular forward scattering in relation to the preoperative one. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Accessibility Attributes of Blood Glucose Meter and Home Blood Pressure Monitor Displays for Visually Impaired Persons

    PubMed Central

    Blubaugh, Morgan V.; Uslan, Mark M.

    2012-01-01

    The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, full-functionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39–1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55–96% and font height ranging 0.28–0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection. PMID:22538132

  20. Impact of personality characteristics on patient satisfaction after multifocal intraocular lens implantation: results from the "happy patient study".

    PubMed

    Mester, Ulrich; Vaterrodt, Thomas; Goes, Frank; Huetz, Werner; Neuhann, Irmingard; Schmickler, Stefanie; Szurman, Peter; Gekeler, Katrin

    2014-10-01

    This prospective multicenter study assessed personality characteristics that may influence patient satisfaction after implantation of multifocal intraocular lenses (MIOLs). One hundred eighty-three patients who underwent bilateral implantation of different MIOLs were enrolled. Uncorrected and corrected distance visual acuity for distance and near (ie, UDVA, UNVA, CDVA, and CNVA) were assessed preoperatively and 3 and 6 months after implantation. Before surgery, personality characteristics were evaluated using a questionnaire based on the NEO Personality Inventory Test and the Compulsiveness Inventory Test. At the 3- and 6-month postoperative visits, patients answered a questionnaire concerning overall satisfaction, need for spectacles at different distances, visual function at different distances and lighting conditions, photic phenomena, and ease of performing daily activities. Three months after surgery (n = 163), mean CDVA was 0.03 ± 0.09 logMAR, UDVA was 0.05 ± 0.09 logMAR, and UNVA was 0.04 ± 0.11 logMAR. At the 6-month visit (n = 131), mean CDVA was 0.02 ± 0.07 logMAR, UDVA was 0.06 ± 0.09 logMAR, and UNVA was 0.05 ± 0.01 logMAR. Most patients (82.2%) would opt for an MIOL again, 3.7% would not, and 14.1% were uncertain. Overall satisfaction with the procedure was correlated to low astigmatism, good visual function, low spectacle dependence, and less halos or glare. The personality characteristics of compulsive checking, orderliness, competence, and dutifulness were statistically significantly correlated to subjective disturbance by glare and halos. Postoperative patient satisfaction after MIOL implantation is correlated to visual performance, spectacle independence, and less photic phenomena. Personality characteristics have an impact on subjective disturbance by photic phenomena and thus are important for patient satisfaction. Copyright 2014, SLACK Incorporated.

  1. Accessibility attributes of blood glucose meter and home blood pressure monitor displays for visually impaired persons.

    PubMed

    Blubaugh, Morgan V; Uslan, Mark M

    2012-03-01

    The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, fullfunctionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39-1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55-96% and font height ranging 0.28-0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection. © 2012 Diabetes Technology Society.

  2. Automatic detection of multi-level acetowhite regions in RGB color images of the uterine cervix

    NASA Astrophysics Data System (ADS)

    Lange, Holger

    2005-04-01

    Uterine cervical cancer is the second most common cancer among women worldwide. Colposcopy is a diagnostic method used to detect cancer precursors and cancer of the uterine cervix, whereby a physician (colposcopist) visually inspects the metaplastic epithelium on the cervix for certain distinctly abnormal morphologic features. A contrast agent, a 3-5% acetic acid solution, is used, causing abnormal and metaplastic epithelia to turn white. The colposcopist considers diagnostic features such as the acetowhite, blood vessel structure, and lesion margin to derive a clinical diagnosis. STI Medical Systems is developing a Computer-Aided-Diagnosis (CAD) system for colposcopy -- ColpoCAD, a complex image analysis system that at its core assesses the same visual features as used by colposcopists. The acetowhite feature has been identified as one of the most important individual predictors of lesion severity. Here, we present the details and preliminary results of a multi-level acetowhite region detection algorithm for RGB color images of the cervix, including the detection of the anatomic features: cervix, os and columnar region, which are used for the acetowhite region detection. The RGB images are assumed to be glare free, either obtained by cross-polarized image acquisition or glare removal pre-processing. The basic approach of the algorithm is to extract a feature image from the RGB image that provides a good acetowhite to cervix background ratio, to segment the feature image using novel pixel grouping and multi-stage region-growing algorithms that provide region segmentations with different levels of detail, to extract the acetowhite regions from the region segmentations using a novel region selection algorithm, and then finally to extract the multi-levels from the acetowhite regions using multiple thresholds. The performance of the algorithm is demonstrated using human subject data.

  3. TOPOGRAPHICALLY GUIDED LASIK FOR MYOPIA USING THE NIDEK CXII CUSTOMIZED ASPHERIC TREATMENT ZONE (CATZ)

    PubMed Central

    Waring, George; Dougherty, Paul J.; Chayet, Arturo; Fischer, Jeffery; Fant, Barbara; Stevens, Gary; Bains, Harkaran S.

    2007-01-01

    Purpose To assess the efficacy, predictability, and safety of topography-guided laser in situ keratomileusis (LASIK) for the surgical correction of low to moderate myopia with astigmatism using the Nidek CXIII excimer laser equipped with the customized aspheric treatment zone (CATz) algorithm. Methods In a multicenter US Food and Drug Administration study of topography-guided LASIK, 4 centers enrolled 135 eyes with manifest refraction sphere that ranged from −0.50 to −7.00 D (mean, −3.57 ± 1.45) with up to −4.00 D of astigmatism (mean, −1.02 ± 0.64 D). The intended outcome was plano in all eyes. Refractive outcomes and higher-order aberrations were analyzed preoperatively and postoperatively. Patient satisfaction was assessed using both the validated Refractive Status and Vision Profile (RSVP) questionnaire and a questionnaire designed for this study. Six-month postoperative outcomes are reported here. Results By 6 months postoperatively, the manifest refraction spherical equivalent (MRSE) for all eyes was −0.09 ± 0.31 D. Six months postoperatively, 116 of 131 eyes (88.55%) had an uncorrected visual acuity of 20/20 or better, and 122 of 131 eyes (93.13%) had a MRSE within ±0.50 D. Distance best spectacle-corrected visual acuity (BSCVA) increased by 2 or more lines in 21 of 131 eyes (19.01%), and no eyes lost 2 lines or more of BSCVA. The total ocular higher-order aberrations root-mean-square increased by 0.04 μm postoperatively. Patients reported significantly fewer night driving and glare and halo symptoms postoperatively than preoperatively. Conclusions Nidek CXIII CATz treatment of myopia with astigmatism is safe, efficacious, and predictable, and it reduces patient symptoms associated with night driving and glare and halo symptoms. PMID:18427614

  4. Adjustable task lighting: Field study assesses the benefits in an office environment.

    PubMed

    Joines, Sharon; James, Tamara; Liu, Siwen; Wang, Wenjiao; Dunn, Rebecca; Cohen, Shane

    2015-01-01

    Lighting is a part of every work task in the office environment, yet it is often overlooked. Research links direct and indirect glare to increased risk of visual discomfort among office workers with symptoms ranging from dry eyes to blurry vision or headaches. Researchers have been primarily concerned with those characteristics of task lighting that cause glare including luminance level, position (line of sight), and control. It is unknown what the benefits of adjustable task lights are and whether or not their use has an effect on musculoskeletal comfort or posture. No comprehensive field evaluations of this type were found among peer-reviewed, indexed journals. The purpose of this study was to assess the ergonomic and calculated utility power consumption benefits of adjustable LED task lighting in an office environment using a control/intervention experiment design. One hundred participants were originally recruited and randomly assigned to intervention and control groups. Self-reported data was collected on level of eye fatigue, perception of job content, intervention usability, and musculoskeletal discomfort. Data was also collected on workspace level of illumination and posture during standardized tasks (assessed using RULA). Comparing baseline data to follow-up data for the intervention group, the use of the adjustable, LED task lights provided statistically significant, positive impacts on users' rating of discomfort, eye fatigue, perception of job content, and posture between baseline and the short-term follow up. Significant benefits to musculoskeletal comfort, posture, and visual comfort were documented when participants used the adjustable task lights. Participants' assessments of the light's usability, usefulness and desirability were positive. There were no negative results found with adjustable task light use.

  5. The Sensitivity of Clinical Outcomes to Centration on the Light-Constricted Pupil for a Shape-Changing Corneal Inlay.

    PubMed

    Barragán-Garza, Enrique; Koch, Douglas D; Vargas, Luis G; Lang, Alan; Roy, Adam

    2018-03-01

    To assess the clinically acceptable range of inlay decentration with respect to the light-constricted pupil center and the coaxially sighted corneal light reflex (CSCLR) for an inlay (Raindrop Near Vision Inlay; ReVision Optics, Inc., Lake Forest, CA) that reshapes the anterior corneal surface. In this retrospective, observational cohort study of 115 patients with emmetropic or low hyperopic presbyopia who were implanted with a shape-changing corneal inlay, visual acuity, task performance (in good and dim light), reports of halos and glare, and satisfaction data were collected from the preoperative and 3-month postoperative examinations. Inlay centration with respect to the pupil center and CSCLR was determined from the center of the inlay effect derived from iTrace (Tracey Technologies, Houston, TX) wavefront measurements. Multivariate regression models assessed the influence of inlay position on visual outcomes. On average, monocular uncorrected near visual acuity (UNVA) improved 4.9 ± 1.7 lines in the treated eye, with no loss in binocular distance vision. Eighty-three percent of implants were centered radially within 0.5 mm of the pupil center. Multivariate analysis of decentration with respect to both the pupil center and CSCLR revealed no significant interaction with the above clinical outcomes, with the exception of UNVA in the treated eye (all P > .05, α = 0.05). For decentration of less than 0.75 mm, the change in UNVA was less than 1 line. Distance and near visual acuity, task performance, severity of halos and glare, and satisfaction were independent of radial decentration of the Raindrop Near Vision Inlay of less than 0.75 mm from the light-constricted pupil. [J Refract Surg. 2018;34(3):164-170.]. Copyright 2018, SLACK Incorporated.

  6. Customized humanoptics silicone iris prosthesis in eyes with posttraumatic iris loss: outcomes and complications.

    PubMed

    Spitzer, Martin Stephan; Nessmann, Anja; Wagner, Julia; Yoeruek, Efdal; Bartz-Schmidt, Karl Ulrich; Szurman, Peter; Szurman, Gesine B

    2016-05-01

    Posttraumatic partial or total iris defects often cause significant debilitating glare, photophobia, decreased vision and cosmetic problems. Currently, the best cosmetic results can be obtained with a customized silicone iris prosthesis. However, little is known about the functional results and the rate of complication if this type of iris prosthesis is implanted into severely traumatized eyes. The aim of this study is to analyse the functional and cosmetic outcomes as well as complications after Artificial Iris implantation. A consecutive series of 34 patients who received a customized silicone iris prosthesis after severe globe injury with total or sub-total iris loss was analysed retrospectively. Additionally, patients were interviewed regarding change in subjective complaints. Median follow-up was 24 months (range 12.0-48.8). Mean visual acuity prior to Artificial Iris implantation was 1.1 logMAR (range 0.3-2.6). Five patients (15%) had pre-existing glaucoma and eight patients (24%) had pre-existing hypotony. Visual acuity 12 months after surgery was 1.4 logMAR (range 0.2-2.6). Complications included newly diagnosed glaucoma in three eyes (9%) and hypotony in three eyes (9%), persisting intraocular inflammation or macular oedema in seven patients (21%), and corneal endothelial decompensation requiring corneal transplantation in six patients (18%). Patients' satisfaction increased by reducing glare and enhanced cosmetic appearance. The customized silicone iris prosthesis is an individualized treatment approach with appealing cosmetic results. Therefore, especially traumatized eyes with highly different posttraumatic conditions could benefit. However, in some patients, the implantation of this device may cause an increase of intraocular pressure, corneal endothelial decompensation or persisting inflammation. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Comparison of Visual Performance of Multifocal Intraocular Lenses with Same Material Monofocal Intraocular Lenses

    PubMed Central

    Yamauchi, Tomofusa; Tabuchi, Hitoshi; Takase, Kosuke; Ohsugi, Hideharu; Ohara, Zaigen; Kiuchi, Yoshiaki

    2013-01-01

    Purpose To compare the visual performance of multifocal intraocular lenses (IOLs) and monofocal IOLs made of the same material. Methods The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00) or Tecnis® multifocal IOLs (ZMA00 or ZMB00) bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patients who were implanted with Tecnis® multifocal IOLs bilaterally. The monofocal group was an age- and sex-matched control group, and included 85 patients who were implanted with Tecnis® monofocal IOLs bilaterally. Lens opacity grading, the radius of corneal curvature, corneal astigmatism, axial length and the refractive status were measured preoperatively. Pupil size, ocular aberrometry, distance, intermediate and near visual acuity, contrast sensitivity with and without glare and the responses to a quality-of-vision questionnaire were evaluated pre- and postoperatively. Results The uncorrected near visual acuity was significantly better in the multifocal group, whereas both the corrected intermediate and near visual acuity were better in the monofocal group. Contrast sensitivity (with and without glare) was significantly better in the monofocal group. The rate of spectacle dependency was significantly lower in the multifocal group. There were no significant differences between the two groups regarding most items of the postoperative quality-of-vision questionnaire (VFQ-25), with the exception that the patients in the monofocal group reported fewer problems with nighttime driving. Conclusions The multifocal IOLs used in this study reduced spectacle dependency more so than monofocal IOLs and did not compromise the subjective visual function, with the exception of nighttime driving. PMID:23840836

  8. Surface-structured diffuser by iterative down-size molding with glass sintering technology.

    PubMed

    Lee, Xuan-Hao; Tsai, Jung-Lin; Ma, Shih-Hsin; Sun, Ching-Cherng

    2012-03-12

    In this paper, a down-size sintering scheme for making high-performance diffusers with micro structure to perform beam shaping is presented and demonstrated. By using down-size sintering method, a surface-structure film is designed and fabricated to verify the feasibility of the sintering technology, in which up to 1/8 dimension reduction has been achieved. Besides, a special impressing technology has been applied to fabricate diffuser film with various materials and the transmission efficiency is as high as 85% and above. By introducing the diffuser into possible lighting applications, the diffusers have been shown high performance in glare reduction, beam shaping and energy saving.

  9. Where is the Earth's missing xenon?

    NASA Technical Reports Server (NTRS)

    Wacker, J. F.; Anders, E.

    1984-01-01

    Highly volatile elements (e.g., T1, Pb, B, C1, Br, etc.) in the Earth's crust occur in C-chondrite proportions, and so do the atmospheric noble gases Ne, Ar, and Kr. This has led to the suggestion that the Earth acquired its volatiles from a late veneer of C-chondrite-like material. A glaring exception is Xe, which is depleted approx. 20x relative to Ne, Ar, Kr. Three explanations are discussed for the depletion: (1) Xe is preferentially trapped in the crust, either in sediments (3) or in Antarctic ice (4); (2) the Earth's noble gas inventory is non-chondritic (5); or (3) Xe is incompletely outgassed from the mantle.

  10. Human Factors Evaluation of Prototype Visor Attachment Sub-systems and Review of Alternative Visor Designs (Evaluation des Facteurs Humains lies aux Prototypes de sous - Systemes de Fixation de Visiere et Critique de Concepts Alternatifs de Visieres)

    DTIC Science & Technology

    2007-02-01

    increase the thermal load generated under the helmet. Based on participant observations of glare reflectance off visor surfaces, many participants...identified between visor conditions for the Glendale spectacles or the Ballistic Spectacles (i.e. UVEX Eye Armour ). Generally , no visor or VASS...Pour ce faire, ils devaient porter jusqu’à quatre sous-systèmes de fixation de visière (VASS) différents et effectuer des mesures répétées : deux

  11. Vision Tests For Medical Surveillance Or To Insure Job Fitness

    NASA Astrophysics Data System (ADS)

    Wolbarsht, M. L.; Landers, M. B.

    1986-05-01

    The rationale for designing screening type eye examinations to document visual capabilities for specific jobs or changes in visual function following exposure to specific ocular hazards is discussed. Possible applications to clinical situations are also discussed. Specific tests meeting requirements of definite end point quantification, ease of administration, and reproducibility are given for contrast (glare) sensitivity, distortions in macular imaging (Amsler grid), and color vision. The selection is aetailed for tne individual test combinations of various populations such as automobile uriver license applicants, visual display operators, and persons exposed to lasers, including military as well as non-military installers and repairers of optical fibers for communications.

  12. Light intensity distribution optimization for tunnel lamps in different zones of a long tunnel.

    PubMed

    Lai, Wei; Liu, Xianming; Chen, Weimin; Lei, Xiaohua; Cheng, Xingfu

    2014-09-22

    The light distributions in different tunnel zones have different requirements in order to meet the driver's visual system. In this paper, the light intensity distributions of tunnel lamps in different zones of a long tunnel are optimized separately. A common nonlinear optimization approach is proposed to minimize the consuming power as well as satisfy the luminance and glare requirements both on the road surface and on the wall set by International Commission on Illumination (CIE). Compared with that of the reported linear optimization method, the optimization model can save energy from 11% to 57.6% under the same installation conditions.

  13. Pupillary Reconstruction and Outcome after Artificial Iris Implantation.

    PubMed

    Mayer, Christian S; Reznicek, Lukas; Hoffmann, Andrea E

    2016-05-01

    Patients with iris defects suffer from severe visual impairment, especially increased glare sensitivity and cosmetic disturbances. This constitutes a great psychological strain for those patients. Until recently, possible treatment options were iris print contact lenses, sunglasses, and simple iris prostheses. The aim of this study was to investigate structural and functional outcome parameters and patient satisfaction after implantation of this new artificial iris prosthesis. Prospective case series investigating functional results and patient satisfaction after surgical iris reconstruction. Thirty-seven consecutive patients with traumatic iris defects presenting from 2011 through 2014 underwent pupillary reconstruction with a new artificial iris implant at the Department of Ophthalmology, Technical University Munich. The custom-made, flexible silicone iris prosthesis ArtificialIris (HumanOptics, Erlangen, Germany) used in this study is a novel and innovative device in the surgical treatment of iris defects. Patients were examined before and after iris reconstruction with the iris implant placed in the ciliary sulcus. Change of best-corrected visual acuity (BCVA), intraocular pressure (IOP), pupillary aperture, glare, contrast sensitivity, endothelial cell density, anterior chamber depth, anterior chamber angle, and patient satisfaction were assessed. Thirty-two eyes of 32 patients (mean age, 52.9±16.0 years) were included. After implantation and during follow-up, BCVA and IOP did not change significantly (BCVA, 0.77±0.62 logarithm of the minimum angle of resolution [logMAR] preoperatively vs. 0.68±0.64 logMAR 1 month postoperatively [P = 0.792]; IOP, 14.94±3.55 mmHg preoperatively vs. 17.72±5.88 mmHg 1 month postoperatively [P = 0.197]). The pupillary aperture was reduced significantly (42.11±20.1 mm(2) to 8.7±0.3 mm(2); P < 0.001). Contrast sensitivity increased significantly (0.80±0.51 to 0.93±0.49; P = 0.014). Endothelial cell count revealed a significant decrease postoperatively (1949±716 per 1 mm(2) to 1841±689 per 1 mm(2); P = 0.003). Anterior chamber depth (4.03±1.06 mm preoperatively vs. 4.29±0.70 mm postoperatively; P = 0.186) and angle (43.2±13.5° preoperatively vs. 40.5±10.8° postoperatively; P = 0.772) showed no significant differences. Subjective impairment through glare (9.12±1.62 preoperatively vs. 3.07±2.29 postoperatively; P < 0.001) and cosmetic disturbance (6.33±3.21 preoperatively vs. 1.58±0.86 postoperatively; P < 0.001) improved significantly. Patient satisfaction with the overall result was 8.91±1.51 of 10 points on an analog scale. The implantation of the artificial iris is a new and effective therapeutic option for the treatment of distinctive traumatic iris defects and results in an individual, aesthetically appealing, and good functional outcome in addition to high patient satisfaction. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. The impact of translucent fabric shades and control strategies on energy savings and visual quality

    NASA Astrophysics Data System (ADS)

    Wankanapon, Pimonmart

    Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric shade colors. The results clearly show the benefit of automatic shade control strategies with integrated lighting control over a condition when shades are closed all day. The main contributor to the total energy savings is from lighting energy savings, followed by cooling energy savings. Shades provide greater benefit in a hot climate and in a moderate climate than in a cold climate. Different control strategies provide savings in the range of 7-35% for annual total space energy with higher savings with light colored shades. Control strategies of shades should be selected and optimized based on climate, orientation, window area, and window/shade properties. High performance glazings, when equipped with shades, show lower energy savings when compared to standard glazings. High transmittance/reflectance shades, such as white shades, perform better than dark shades in most of the cases due to higher lighting energy savings obtained with the automatic electric lighting control and the resulting cooling energy savings from rejection of some solar energy and a reduction in the heat from lights. A South orientation showed the least benefit of automatic control of shades when compare to other orientations due to the large fraction of time shades are required to provide visual comfort. Under automatic shade control, energy savings are higher the more often the shades can be raised. The different automatic control strategies present tradeoffs between energy savings and comfort. With regard to visual quality, daylight quality assessments on view, glare, luminance ratios, and UDI can be used to assess shade control strategies. Automatic shade control can increase the number of view hours while controlling sunlight penetration. With automatic shade control, more daylight hours can be provided within the beneficial range of 100-2000 lux compared to shades that are closed all day. For a person facing the window, discomfort glare is likely to increase the more often the shades are raised. Keeping the shades down ensures an acceptable glare condition, but limits energy savings. Luminance ratios are another metric that can be used to assess shade performance. With white shades, the luminance ratios between the task and proximate surfaces are improved. Dark shades help improve the luminance ratios between the task and distant surfaces. When the shades are left open, even with no direct sunlight in the space, task to window luminance ratios will often exceed 1:10.

  15. Near-infrared light-guided miniaturized indirect ophthalmoscopy for nonmydriatic wide-field fundus photography.

    PubMed

    Toslak, Devrim; Liu, Changgeng; Alam, Minhaj Nur; Yao, Xincheng

    2018-06-01

    A portable fundus imager is essential for emerging telemedicine screening and point-of-care examination of eye diseases. However, existing portable fundus cameras have limited field of view (FOV) and frequently require pupillary dilation. We report here a miniaturized indirect ophthalmoscopy-based nonmydriatic fundus camera with a snapshot FOV up to 67° external angle, which corresponds to a 101° eye angle. The wide-field fundus camera consists of a near-infrared light source (LS) for retinal guidance and a white LS for color retinal imaging. By incorporating digital image registration and glare elimination methods, a dual-image acquisition approach was used to achieve reflection artifact-free fundus photography.

  16. Cross-polarised and parallel-polarised light: Viewing and photography for examination and documentation of biological materials in medicine and forensics.

    PubMed

    Hanlon, Katharine L

    2018-01-01

    Cross-polarisation, with regard to visible light, is a process wherein two polarisers with perpendicular orientation to one another are used on the incident and reflected lights. Under cross-polarised light birefringent structures which are otherwise invisible become apparent. Cross-polarised light eliminates glare and specular highlights, allowing for an unobstructed view of subsurface pathology. Parallel-polarisation occurs when the polarisers are rotated to the same orientation. When cross- or parallel-polarisation is applied to photography, images can be generated which aid in visualisation of surface and subsurface elements. Improved access to equipment and education has the potential to benefit practitioners, researchers, investigators and patients.

  17. Reflectors with directional-mixed reflection properties for application in luminaries with high-power LED diodes

    NASA Astrophysics Data System (ADS)

    Zaremba, Krzysztof

    2008-06-01

    Application of directional-mixed reflectors results in a luminance decrease of the apparent image of light emitting diodes (LEDs), which is advantageous as far as glare reduction is concerned. On the other hand, reflectors have a negative impact on luminous intensity curves of the luminaries. This work analyzes an impact of surfaces with directional-mixed reflection properties in a mirror reflector designed for a luminary equipped with high-power LEDs. We present an algorithm used to determine the shape of the reflector of the surface with small scattering, where the axis twist angle for a parabolic reflector varies in a predefined range and follows a power function.

  18. From red star rising to rocket's red glare: space travel, the early years

    NASA Astrophysics Data System (ADS)

    Chapman, Steven

    2007-07-01

    'We choose to go to the Moon in this decade and do the other things, not because they are easy, but because they are hard, because that goal will serve to organize and measure the best of our energies and skills, because that challenge is one that we are willing to accept, one we are unwilling to postpone, and one which we intend to win, and the others, too.' President John Fitzgerald Kennedy, 12 September 1962. It is now 50 years since the first artificial satellite was launched. This article looks at the early years of space travel and some of the key moments during that time.

  19. Optic Neuritis: Another Dickensian Diagnosis

    PubMed Central

    Petzold, Axel

    2013-01-01

    Abstract The clinical diagnosis and natural history of optic neuritis was established in the late 1880s by the ophthalmologists von Graefe and Nettleship. The earlier, accurate and insightful description of transient, bilateral visual loss of Esther, the main character in the Charles Dickens novel Bleak House (1852--1853), suggests optic neuritis as a Dickensian diagnosis. Remarkably, Dickens’ observations, also preceding the earliest clinical description of multiple sclerosis by Charcot in 1868, described many clinical features such as a prodromal phase; a nadir; gradual recovery over weeks; glare disability; reduced contrast sensitivity; possibly Uhthoff’s phenomenon; and visual fading. All this with an accuracy that, to quote Russell Brain, “would credit a trained physician.” PMID:28167994

  20. Volumetric soft tissue brain imaging on xCAT, a mobile flat-panel x-ray CT system

    NASA Astrophysics Data System (ADS)

    Zbijewski, Wojciech; Stayman, J. Webster

    2009-02-01

    We discuss the ongoing development of soft-tissue imaging capabilities on xCAT, a highly portable, flat-panel based cone-beam X-ray CT platform. By providing the ability to rapidly detect intra-cranial bleeds and other symptoms of stroke directly at the patient's bedside, our new system can potentially significantly improve the management of neurological emergency and intensive care patients. The paper reports on the design of our system, as well as on the methods used to combat artifacts due to scatter, non-linear detector response and scintillator glare. Images of cadaveric head samples are also presented and compared with conventional CT scans.

  1. Black Lives Matter: A Commentary on Racism and Public Health.

    PubMed

    Jee-Lyn García, Jennifer; Sharif, Mienah Zulfacar

    2015-08-01

    The recent nonindictments of police officers who killed unarmed Black men have incited popular and scholarly discussions on racial injustices in our legal system, racialized police violence, and police (mis)conduct. What is glaringly absent is a public health perspective in response to these events. We aim to fill this gap and expand the current dialogue beyond these isolated incidents to a broader discussion of racism in America and how it affects the health and well-being of people of color. Our goal is not only to reiterate how salient structural racism is in our society, but how critical antiracist work is to the core goals and values of public health.

  2. Like grandfather, like grandson: Erasmus and Charles Darwin on evolution.

    PubMed

    Smith, C U M

    2010-01-01

    Last year (2009) marked the bicentenary of Charles Darwin's birth and the sesquicentenary of The Origin of Species. This article examines the influence of Erasmus Darwin on Charles's evolutionary thought and shows how, in many ways, Erasmus anticipated his much better-known grandson. It discusses the similarity in the mindsets of the two Darwins, asks how far the younger Darwin was exposed to the elder's evolutionary thought, examines the similarities and differences in their theories of evolution, and ends by showing the surprising similarity between their theories of inheritance. Erasmus's influence on Charles is greater than customarily acknowledged, and now is an opportune time to bring the grandfather out from behind the glare of his stellar grandson.

  3. Black Lives Matter: A Commentary on Racism and Public Health

    PubMed Central

    Jee-Lyn García, Jennifer

    2015-01-01

    The recent nonindictments of police officers who killed unarmed Black men have incited popular and scholarly discussions on racial injustices in our legal system, racialized police violence, and police (mis)conduct. What is glaringly absent is a public health perspective in response to these events. We aim to fill this gap and expand the current dialogue beyond these isolated incidents to a broader discussion of racism in America and how it affects the health and well-being of people of color. Our goal is not only to reiterate how salient structural racism is in our society, but how critical antiracist work is to the core goals and values of public health. PMID:26066958

  4. Blue-Light Filtering Spectacle Lenses: Optical and Clinical Performances.

    PubMed

    Leung, Tsz Wing; Li, Roger Wing-Hong; Kee, Chea-Su

    2017-01-01

    To evaluate the optical performance of blue-light filtering spectacle lenses and investigate whether a reduction in blue light transmission affects visual performance and sleep quality. Experiment 1: The relative changes in phototoxicity, scotopic sensitivity, and melatonin suppression of five blue-light filtering plano spectacle lenses were calculated based on their spectral transmittances measured by a spectrophotometer. Experiment 2: A pseudo-randomized controlled study was conducted to evaluate the clinical performance of two blue-light filtering spectacle lenses (BF: blue-filtering anti-reflection coating; BT: brown-tinted) with a regular clear lens (AR) serving as a control. A total of eighty computer users were recruited from two age cohorts (young adults: 18-30 yrs, middle-aged adults: 40-55 yrs). Contrast sensitivity under standard and glare conditions, and colour discrimination were measured using standard clinical tests. After one month of lens wear, subjective ratings of lens performance were collected by questionnaire. All tested blue-light filtering spectacle lenses theoretically reduced the calculated phototoxicity by 10.6% to 23.6%. Although use of the blue-light filters also decreased scotopic sensitivity by 2.4% to 9.6%, and melatonin suppression by 5.8% to 15.0%, over 70% of the participants could not detect these optical changes. Our clinical tests revealed no significant decrease in contrast sensitivity either with (95% confidence intervals [CI]: AR-BT [-0.05, 0.05]; AR-BF [-0.05, 0.06]; BT-BF [-0.06, 0.06]) or without glare (95% CI: AR-BT [-0.01, 0.03]; AR-BF [-0.01, 0.03]; BT-BF [-0.02, 0.02]) and colour discrimination (95% CI: AR-BT [-9.07, 1.02]; AR-BF [-7.06, 4.46]; BT-BF [-3.12, 8.57]). Blue-light filtering spectacle lenses can partially filter high-energy short-wavelength light without substantially degrading visual performance and sleep quality. These lenses may serve as a supplementary option for protecting the retina from potential blue-light hazard. ClinicalTrials.gov NCT02821403.

  5. Functional Magnetic Resonance Imaging to Assess the Neurobehavioral Impact of Dysphotopsia with Multifocal Intraocular Lenses.

    PubMed

    Rosa, Andreia M; Miranda, Ângela C; Patrício, Miguel; McAlinden, Colm; Silva, Fátima L; Murta, Joaquim N; Castelo-Branco, Miguel

    2017-09-01

    To investigate the association between dysphotopsia and neural responses in visual and higher-level cortical regions in patients who recently received multifocal intraocular lens (IOL) implants. Cross-sectional study. Thirty patients 3 to 4 weeks after bilateral cataract surgery with diffractive IOL implantation and 15 age- and gender-matched control subjects. Functional magnetic resonance imaging (fMRI) was performed when participants viewed low-contrast grating stimuli. A light source surrounded the stimuli in half of the runs to induce disability glare. Visual acuity, wavefront analysis, Quality of Vision (QoV) questionnaire, and psychophysical assessment were performed. Cortical activity (blood oxygen level dependent [BOLD] signal) in the primary visual cortex and in higher-level brain areas, including the attention network. When viewing low-contrast stimuli under glare, patients showed significant activation of the effort-related attention network in the early postoperative period, involving the frontal, middle frontal, parietal frontal, and postcentral gyrus (multisubject random-effects general linear model (GLM), P < 0.03). In contrast, controls showed only relative deactivation (due to lower visibility) of visual areas (occipital lobe and middle occipital gyrus, P < 0.03). Patients also had relatively stronger recruitment of cortical areas involved in learning (anterior cingulate gyrus), task planning, and solving (caudate body). Patients reporting greater symptoms induced by dysphotic symptoms showed significantly increased activity in several regions in frontoparietal circuits, as well as cingulate gyrus and caudate nucleus (q < 0.05). We found no correlation between QoV questionnaire scores and optical properties (total and higher order aberration, modulation transfer function, and Strehl ratio). This study shows the association between patient-reported subjective difficulties and fMRI outcomes, independent of optical parameters and psychophysical performance. The increased activity of cortical areas dedicated to attention (frontoparietal circuits), to learning and cognitive control (cingulate), and to task goals (caudate) likely represents the beginning of the neuroadaptation process to multifocal IOLs. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Functional outcome and patient satisfaction after laser in situ keratomileusis for correction of myopia and myopic astigmatism.

    PubMed

    Bamashmus, Mahfouth A; Hubaish, Khammash; Alawad, Mohammed; Alakhlee, Hisham

    2015-01-01

    The purpose was to evaluate subjective quality of vision and patient satisfaction after laser in situ keratomileusis (LASIK) for myopia and myopic astigmatism. A self-administered patient questionnaire consisting 29 items was prospectively administered to LASIK patients at the Yemen Magrabi Hospital. Seven scales covering specific aspects of the quality of vision were formulated including; global satisfaction; quality of uncorrected and corrected vision; quality of night vision; glare; daytime driving and; night driving. Main outcome measures were responses to individual questions and scale scores and correlations with clinical parameters. The scoring scale ranged from 1 (dissatisfied) to 3 (very satisfied) and was stratified in the following manner: 1-1.65 = dissatisfied; 1.66-2.33 = satisfied and; 2.33-3 = very satisfied. Data at 6 months postoperatively are reported. This study sample was comprised of 200 patients (122 females: 78 males) ranging in age from 18 to 46 years old. The preoperative myopic sphere was - 3.50 ± 1.70 D and myopic astigmatism was 0.90 ± 0.82 D. There were 96% of eyes within ± 1.00 D of the targeted correction. Postoperatively, the uncorrected visual acuity was 20/40 or better in 99% of eyes. The mean score for the overall satisfaction was 2.64 ± 0.8. A total of 98.5% of patients was satisfied or very satisfied with their surgery, 98.5% considered their main goal for surgery was achieved. Satisfaction with uncorrected vision was 2.5 ± 0.50. The main score for glare was 1.98 ± 0.7 at night. Night driving was rated more difficult preoperatively by 6.2%, whereas 79% had less difficulty driving at night. Patient satisfaction with uncorrected vision after LASIK for myopia and myopic astigmatism appears to be excellent and is related to the residual refractive error postoperatively.

  7. Functional Outcome and Patient Satisfaction after Laser In Situ Keratomileusis for Correction of Myopia and Myopic Astigmatism

    PubMed Central

    Bamashmus, Mahfouth A.; Hubaish, Khammash; Alawad, Mohammed; Alakhlee, Hisham

    2015-01-01

    Purpose: The purpose was to evaluate subjective quality of vision and patient satisfaction after laser in situ keratomileusis (LASIK) for myopia and myopic astigmatism. Patients and Methods: A self-administered patient questionnaire consisting 29 items was prospectively administered to LASIK patients at the Yemen Magrabi Hospital. Seven scales covering specific aspects of the quality of vision were formulated including; global satisfaction; quality of uncorrected and corrected vision; quality of night vision; glare; daytime driving and; night driving. Main outcome measures were responses to individual questions and scale scores and correlations with clinical parameters. The scoring scale ranged from 1 (dissatisfied) to 3 (very satisfied) and was stratified in the following manner: 1-1.65 = dissatisfied; 1.66-2.33 = satisfied and; 2.33-3 = very satisfied. Data at 6 months postoperatively are reported. Results: This study sample was comprised of 200 patients (122 females: 78 males) ranging in age from 18 to 46 years old. The preoperative myopic sphere was − 3.50 ± 1.70 D and myopic astigmatism was 0.90 ± 0.82 D. There were 96% of eyes within ± 1.00 D of the targeted correction. Postoperatively, the uncorrected visual acuity was 20/40 or better in 99% of eyes. The mean score for the overall satisfaction was 2.64 ± 0.8. A total of 98.5% of patients was satisfied or very satisfied with their surgery, 98.5% considered their main goal for surgery was achieved. Satisfaction with uncorrected vision was 2.5 ± 0.50. The main score for glare was 1.98 ± 0.7 at night. Night driving was rated more difficult preoperatively by 6.2%, whereas 79% had less difficulty driving at night. Conclusion: Patient satisfaction with uncorrected vision after LASIK for myopia and myopic astigmatism appears to be excellent and is related to the residual refractive error postoperatively. PMID:25624684

  8. Visibility and Visual Characteristics of the Ivanpah Solar Electric Generating System Power Tower Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Robert; Abplanalp, Jennifer M.

    2015-03-01

    This report presents the results of a study conducted to document the visibility and visual characteristics of the Ivanpah Solar Electric Generating System (ISEGS), a utility-scale solar power tower facility located on land administered by the U.S. Department of the Interior Bureau of Land Management in southern California. Study activities consisted of field observations of the ISEGS facility and comparison of the observations made in the field with the visual contrast assessments and visual simulations in the ISEGS Final Environmental Impact Statement (Final EIS) and supporting documents created prior to ISEGS construction. Field observations of ISEGS were made from 19more » locations within 35 mi (56 km) of the facility in the course of one week in September 2014. The study results established that reflected sunlight from the receivers was the primary source of visual contrast from the operating ISEGS facility. The ISEGS facility was found to be a major source of visual contrast for all observations up to 20 mi (32 km), and was easily visible at 35 mi. Glare from individual heliostats was frequently visible, and often brighter than the reflected light from the receivers. Heliostat glare caused discomfort for one or more viewers at distances up to 20 mi. The ISEGS power blocks were brightly lit at night, and were conspicuous at the observation distance of approximately 6 mi (10 km). The facility is substantially brighter and is seen more clearly in the field than in photographs of the facility or in the prepared simulations, which were based on photographs. The simulations of the ISEGS facility in the Final EIS, which were evaluated as part of this study, sometimes lacked spatial accuracy and realism. The evaluated simulations generally under-represented the actual visual contrast from the project, and some of the contrast ratings in the Final EIS predicted substantially lower levels of visual contrast than were actually observed for the operating facility.« less

  9. Nondestructive Testing of Overhead Transmission LINES—NUMERICAL and Experimental Investigation

    NASA Astrophysics Data System (ADS)

    Kulkarni, S.; Hurlebaus, S.

    2009-03-01

    Overhead transmission lines are periodically inspected using both on-ground and helicopter-aided visual inspection. Factors including sun glare, cloud cover, close proximity to power lines and the rapidly changing visual circumstances make airborne inspection of power lines a particularly hazardous task. In this study, a finite element model is developed that can be used to create the theoretical dispersion curves of an overhead transmission line. The numerical results are then verified with experimental test using a non-contact and broadband laser detection technique. The methodology developed in this study can be further extended to a continuous monitoring system and be applied to other cable monitoring applications, such as bridge cable monitoring, which would otherwise put human inspectors at risk.

  10. Impact of computer use on children's vision.

    PubMed

    Kozeis, N

    2009-10-01

    Today, millions of children use computers on a daily basis. Extensive viewing of the computer screen can lead to eye discomfort, fatigue, blurred vision and headaches, dry eyes and other symptoms of eyestrain. These symptoms may be caused by poor lighting, glare, an improper work station set-up, vision problems of which the person was not previously aware, or a combination of these factors. Children can experience many of the same symptoms related to computer use as adults. However, some unique aspects of how children use computers may make them more susceptible than adults to the development of these problems. In this study, the most common eye symptoms related to computer use in childhood, the possible causes and ways to avoid them are reviewed.

  11. Relationship between Secchi disc readings and light penetration in Lake Huron

    USGS Publications Warehouse

    Beeton, Alfred M.

    1958-01-01

    Fifty-seven paired photometer and Secchi disc measurements made at 18 stations in Saginaw Bay and Lake Huron support the view that a counter-clockwise current usually occurs in the Bay with more transparent Lake Huron water flowing in along the northwest shore and less transparent Bay water flowing out along the southeast shore. The average percentage transmission of surface light intensity, at the Secchi disc depth, was 14.7 percent. Discrepancies in the relationship of disc readings to percentage transmission of surface light are related to the condition of the sky and sea. It is suggested that these discrepancies can best be explained on the basis of the spectral sensitivity of the human eye and its response to surface glare.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Materials developed by NIOSH concerning video display terminals (VDTs) comprise the publication. The first section listed citations of reports developed by NIOSH concerning VDTs and possible hazards associated with their use, and contained ordering information for these publications. Types of publications included NIOSH numbered publications, hazard evaluation and technical assistance reports, contract reports, journal articles, book chapters, presentations, and miscellaneous reports. The second section of the report contained full text copies of selected references from the bibliography. These references included testimony before congressional committees, presentations and articles dealing with radiation issues, reproductive outcomes of workers using VDTs the risk ofmore » spontaneous abortion, an epidemiologic investigation of electric and magnetic fields and operator exposure, controlling glare problems in the VDT work environment, and the design of rest breaks for VDT operators.« less

  13. Adopting new models for continuity of care: what are the needs?

    PubMed

    May, P R

    1975-09-01

    There are glaring, almost universal deficiencies in the organization of community resources for treating and rehabilitating the mentally ill, particularly psychotic patients, the author says. The deficiencies could be partly remedied by reorganizing psychiatric hospitals to play a key role in outpatient service delivery, and by paying more attention to the principles of continuity of care for psychotic patients. One way of doing both is through the model of a mini-mental-health-center adopted at a Veterans Administration hospital: the same terms provide active, continual care for patients regardless of whether they are in or out of the hospital. The program developed on one ward is described further in the next paper, written by ward staff members and others.

  14. Radiation Blocking Lenses

    NASA Technical Reports Server (NTRS)

    1993-01-01

    The Biomedical Optical Company of America's Eagle 475 lens absorbs 100 percent of all photowavelengths considered hazardous to eye tissue, including ultraviolet and blue light, which are considered contributors to cataract and age-related macular degeneration. The lens absorbs hazardous wavelengths, but allows a higher percentage of visually useful areas of the spectrum to pass through. Polarization blocks out irritating glint and glare and heightens visual acuity. The Eagle 475 sunglasses are the latest in a series of spinoffs that originated at the Jet Propulsion Laboratory where two scientists developed a protective, welding curtain that filtered out harmful irradiance. The result was a commercial curtain that absorbs filters and scatters light, providing protection for personnel in welding areas. Further research focused on protective industrial glasses and later on consumer products.

  15. Life cycle assessment of a road safety product made with virgin and recycled HDPE.

    PubMed

    Simões, Carla L; Xará, Susana M; Bernardo, C A

    2011-04-01

    The present study aims at evaluating the potential environmental impact of using recycled high-density polyethylene (HDPE) in the production of an anti-glare lamella (AGL), a road safety device currently manufactured from virgin (not recycled) polymer. The impact was evaluated using the life cycle assessment (LCA) technique and comparing two alternative systems: current AGL, manufactured from virgin HDPE, and optional AGL, made with recycled HDPE obtained from post-consumer packages. The AGL manufacturing phase was found to be responsible for most of the impacts in both systems, with the production of the raw material being the largest contributor for that phase. The present study makes a contribution to the problem of developing value-added products made from post-consumer polymeric recyclates.

  16. Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samei, Ehsan; Badano, Aldo; Chakraborty, Dev

    Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction withmore » specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (L{sub amb}) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than 170/100 cd/m{sup 2}, LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than 30%/60% and LR is greater than 175/70 for primary/secondary displays, or alternatively, within which the on-axis contrast thresholds of the TG18-CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18-UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18-QC or TG18-CX test patterns, which should yield scores greater than 4/6 for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18-AFC test pattern, which should yield a minimum of 3/2 targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low-contrast targets of the TG18-GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than 3/1 and GRs greater than 400/150 for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a u{sup '},v{sup '} color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.« less

  17. Blue-Light Filtering Spectacle Lenses: Optical and Clinical Performances

    PubMed Central

    2017-01-01

    Purposes To evaluate the optical performance of blue-light filtering spectacle lenses and investigate whether a reduction in blue light transmission affects visual performance and sleep quality. Methods Experiment 1: The relative changes in phototoxicity, scotopic sensitivity, and melatonin suppression of five blue-light filtering plano spectacle lenses were calculated based on their spectral transmittances measured by a spectrophotometer. Experiment 2: A pseudo-randomized controlled study was conducted to evaluate the clinical performance of two blue-light filtering spectacle lenses (BF: blue-filtering anti-reflection coating; BT: brown-tinted) with a regular clear lens (AR) serving as a control. A total of eighty computer users were recruited from two age cohorts (young adults: 18–30 yrs, middle-aged adults: 40–55 yrs). Contrast sensitivity under standard and glare conditions, and colour discrimination were measured using standard clinical tests. After one month of lens wear, subjective ratings of lens performance were collected by questionnaire. Results All tested blue-light filtering spectacle lenses theoretically reduced the calculated phototoxicity by 10.6% to 23.6%. Although use of the blue-light filters also decreased scotopic sensitivity by 2.4% to 9.6%, and melatonin suppression by 5.8% to 15.0%, over 70% of the participants could not detect these optical changes. Our clinical tests revealed no significant decrease in contrast sensitivity either with (95% confidence intervals [CI]: AR–BT [–0.05, 0.05]; AR–BF [–0.05, 0.06]; BT–BF [–0.06, 0.06]) or without glare (95% CI: AR–BT [–0.01, 0.03]; AR–BF [–0.01, 0.03]; BT–BF [–0.02, 0.02]) and colour discrimination (95% CI: AR–BT [–9.07, 1.02]; AR–BF [–7.06, 4.46]; BT–BF [–3.12, 8.57]). Conclusion Blue-light filtering spectacle lenses can partially filter high-energy short-wavelength light without substantially degrading visual performance and sleep quality. These lenses may serve as a supplementary option for protecting the retina from potential blue-light hazard. Trial Registration ClinicalTrials.gov NCT02821403 PMID:28045969

  18. Post DSAEK Optical Changes: A Comprehensive Prospective Analysis on the Role of Ocular Wavefront Aberrations, Haze, and Corneal Thickness

    PubMed Central

    Hindman, Holly B.; Huxlin, Krystel R.; Pantanelli, Seth M.; Callan, Christine L.; Sabesan, Ramkumar; Ching, Steven S.T.; Miller, Brooke E.; Martin, Tim; Yoon, Geunyoung

    2014-01-01

    Purpose To assess the visual impact of ocular wavefront aberrations, corneal thickness, and corneal light scatter prospectively after Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK) in humans. Methods Data were obtained prospectively from 20 eyes pre-operatively and at 1, 3, 6, and 12 months post- DSAEK. At each visit, best spectacle corrected visual acuity (BSCVA) and visual acuity with glare (Brightness Acuity Testing - BAT) were recorded and ocular wavefront measurements and corneal Optical Coherence Tomography (OCT) performed. Magnitude and sign of individual Zernike terms (higher order aberrations HOA) were determined. Epithelial, host stromal, donor stromal, and total corneal thickness were quantified. Brightness, intensity profiles of OCT images were generated to quantify light scatter in the whole cornea, subepithelial region, anterior and posterior host stroma, interface, and donor stroma. Results Mean BSCVA and glare disability at low light levels improved from 1 to 12 months post-DSAEK. All corneal thicknesses and ocular lower- and HOAs were stable from 1 through 12 months, whereas total corneal, host stromal, and interface brightness intensities decreased significantly over the same period. A repeated measures ANOVA across the follow up period found that the change in scatter, but not the change in higher order aberrations, could account for the variability occurring in acuity from 1 to 12 months post-DSAEK. Conclusions While ocular HOAs and scatter are both elevated over normal post-DSAEK, our results demonstrate that improvements in visual performance occurring over the first year post-DSAEK are associated with decreasing light scatter. In contrast, there were no significant changes in ocular HOAs during this time. Because corneal light scatter decreased between 1 and 12 months despite stable corneal thicknesses over the same period, we conclude that factors that induced light scatter, other than tissue thickness or swelling (corneal edema), significantly impacted the visual improvements that occurred over time post-DSAEK. A better understanding of the cellular and extracellular matrix changes of the subepithelial region and interface, incurred by the surgical creation of a lamellar host -graft interface, and the subsequent healing of these tissues, is warranted. PMID:24162748

  19. Rose-K versus Soper contact lens in keratoconus: a randomized comparative trial.

    PubMed

    Gupta, Raghav; Sinha, Rajesh; Singh, Pooja; Sharma, Namrata; Tandon, Radhika; Titiyal, Jeewan S

    2014-01-01

    To perform a comparative evaluation of the efficacy and acceptability of Rose-K and Soper contact lenses in Keratoconus. Dr. Rajendra Prasad Center for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi. A randomized comparative clinical trial was performed in keratoconic eyes fitted with Rose-K (Rose-K group) and Soper (Soper group) contact lenses. Patients data were evaluated for best spectacle corrected visual acuity, best contact lens corrected visual acuity (BCLCVA), corneal topography, glare acuity, contrast sensitivity, tear function tests and specular microscopy. Patients were also asked to complete a self-reported comfort questionnaire at each visit. Sixty eyes were randomized to the Rose-K and Soper groups. The two groups were comparable in all the baseline parameters. There was a statistically significant improvement in BCLCVA in both groups at 3 months (P < 0.01, both groups). The difference between in BCLCVA in both groups was not statistically significant. In both groups, there was a significant improvement in the comfort score at 3 months compared to baseline (P < 0.05, both group). The Rose-K group had statistically significantly better scores at 1 and 3 months compared with the Soper group (P = 0.006 and P < 0.001 respectively). Both groups were associated with a significant (P < 0.01), but comparable improvement in glare acuity at 3 months. There was a significant improvement in contrast sensitivity at 3 months in both groups (P < 0.01); the Rose-K group was significantly better than the Soper group at 1 and 3 months (P = 0.001 and 0.002 respectively). The mean number of trial lenses required for fitting Rose-K lens (2.00 ± 0.59) was significantly lower than the Soper lens (3.43 ± 0.82; P < 0.001). Both the contact lens designs provide an equal improvement in visual acuity in patients with Keratoconus. However, Rose-K contact lens provides greater comfort, better quality of vision and requires less chair time compared with the Soper lens and hence may possibly have a greater acceptability.

  20. Understanding and preventing computer vision syndrome.

    PubMed

    Loh, Ky; Redd, Sc

    2008-01-01

    The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syndrome are extraocular mechanism, accommodative mechanism and ocular surface mechanism. The visual effects of the computer such as brightness, resolution, glare and quality all are known factors that contribute to computer vision syndrome. Prevention is the most important strategy in managing computer vision syndrome. Modification in the ergonomics of the working environment, patient education and proper eye care are crucial in managing computer vision syndrome.

  1. Ergonomics improvements of the visual inspection process in a printed circuit assembly factory.

    PubMed

    Yeow, Paul H P; Sen, Rabindra Nath

    2004-01-01

    An ergonomics improvement study was conducted on the visual inspection process of a printed circuit assembly (PCA) factory. The process was studied through subjective assessment and direct observation. Three problems were identified: operators' eye problems, insufficient time for inspection and ineffective visual inspection. These problems caused a huge yearly rejection cost of US 298,240 dollars, poor quality, customer dissatisfaction and poor occupational health and safety. Ergonomics interventions were made to rectify the problems: reduced usage of a magnifying glass, the use of less glaring inspection templates, inspection of only electrically non-tested components and introduction of a visual inspection sequence. The interventions produced savings in rejection cost, reduced operators' eye strain, headaches and watery eyes, lowered the defect percentage at customers' sites and increased the factory's productivity and customer satisfaction.

  2. Measurements of UGR of LED light by a DSLR colorimeter

    NASA Astrophysics Data System (ADS)

    Hsu, Shau-Wei; Chen, Cheng-Hsien; Jiaan, Yuh-Der

    2012-10-01

    We have developed an image-based measurement method on UGR (unified glare rating) of interior lighting environment. A calibrated DSLR (digital single-lens reflex camera) with an ultra wide-angle lens was used to measure the luminance distribution, by which the corresponding parameters can be automatically calculated. A LED lighting was placed in a room and measured at various positions and directions to study the properties of UGR. The testing results are fitted with visual experiences and UGR principles. To further examine the results, a spectroradiometer and an illuminance meter were respectively used to measure the luminance and illuminance at the same position and orientation of the DSLR. The calculation of UGR by this image-based method may solve the problem of non-uniform luminance-distribution of LED lighting, and was studied on segmentation of the luminance graph for the calculations.

  3. NREL Electrochromic Window Research Wins Award

    ScienceCinema

    None

    2017-12-09

    Winners of the CO-LABS Governor's Award for High-Impact Research in Energy Efficiency, Dr. Satyen Deb at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) discovered that a small electrical charge can change the opacity of tungsten oxide from clear to tinted. He, Dr. Dane Gillaspie, and their fellow scientists at NREL then applied this knowledge to develop and transfer the technologies required to construct an electrochromic window, which can switch between clear and heavily tinted states. Electrochromic windows allow natural light in while adding tint to reduce summer heat and glare, and going clear to allow sunlight through in the winter. Broad adaptation of these windows could reduce US total energy use by four percent and reduce building cooling loads by 20%, much of this during expensive peak hours. Windows based on these discoveries are now being installed worldwide.

  4. Functional considerations in evaluation and treatment of the client with low vision.

    PubMed

    Lampert, J; Lapolice, D J

    1995-10-01

    In evaluating and treating clients who have low vision, the occupational therapist must consider factors in addition to typical measures of the client's visual acuity, field loss, and oculomotor control. It is important to consider the functional implications of the client's ocular pathology, including illumination needs, contrast sensitivity, sensitivity to glare, and need for magnification as well as environmental factors such as the amount of pattern in a visual task, the amount of lighting and contrast available, and the conditions under which the task is performed. These factors are all relevant to occupational therapy low vision rehabilitation because each may influence the way in which a client uses his or her residual vision and achieves successful adaptation. This article provides an overview of these factors and presents a suggested protocol for evaluation of the client with low vision.

  5. Evaluating visual function in cataract.

    PubMed

    Elliott, D B

    1993-11-01

    This paper reviews recent research on the evaluation of visual function in cataract. Visual impairment in cataract is principally caused by increased intraocular forward light scatter. It is assumed that visual acuity (VA) measurements assess the impact of narrow angle light scatter. This also makes the measurement of high spatial frequency contrast sensitivity (CS) unnecessary. However, VA measurements alone are an inadequate assessment of visual impairment in some patients with cataract. In addition, it is suggested that a measurement of wide-angle light scatter is required. This can be evaluated directly using the van den Berg Straylightmeter, or indirectly using low spatial frequency CS or disability glare (DG) tests. The following are discussed: (1) the relative usefulness of these tests; (2) how they can be incorporated into the decision as to when to extract a cataract; and (3) the importance of considering binocular visual function.

  6. Performance tests and quality control of cathode ray tube displays.

    PubMed

    Roehrig, H; Blume, H; Ji, T L; Browne, M

    1990-08-01

    Spatial resolution, noise, characteristic curve, and absolute luminance are the essential parameters that describe physical image quality of a display. This paper presents simple procedures for assessing the performance of a cathode ray tube (CRT) in terms of these parameters as well as easy set up techniques. The procedures can be used in the environment where the CRT is used. The procedures are based on a digital representation of the Society of Motion Pictures and Television Engineers pattern plus a few simple other digital patterns. Additionally, measurement techniques are discussed for estimating brightness uniformity, veiling glare, and distortion. Apart from the absolute luminance, all performance features can be assessed with an uncalibrated photodetector and the eyes of a human observer. The measurement techniques especially enable the user to perform comparisons of different display systems.

  7. A context-adaptable approach to clinical guidelines.

    PubMed

    Terenziani, Paolo; Montani, Stefania; Bottrighi, Alessio; Torchio, Mauro; Molino, Gianpaolo; Correndo, Gianluca

    2004-01-01

    One of the most relevant obstacles to the use and dissemination of clinical guidelines is the gap between the generality of guidelines (as defined, e.g., by physicians' committees) and the peculiarities of the specific context of application. In particular, general guidelines do not take into account the fact that the tools needed for laboratory and instrumental investigations might be unavailable at a given hospital. Moreover, computer-based guideline managers must also be integrated with the Hospital Information System (HIS), and usually different DBMS are adopted by different hospitals. The GLARE (Guideline Acquisition, Representation and Execution) system addresses these issues by providing a facility for automatic resource-based adaptation of guidelines to the specific context of application, and by providing a modular architecture in which only limited and well-localised changes are needed to integrate the system with the HIS at hand.

  8. Intraocular Lenses for the Treatment of Age-Related Cataracts

    PubMed Central

    2009-01-01

    Executive Summary Objective The objective of the report is to examine the comparative effectiveness and cost-effectiveness of various intraocular lenses (IOLs) for the treatment of age-related cataracts. Clinical Need: Target Population and Condition A cataract is a hardening and clouding of the normally transparent crystalline lens that may result in a progressive loss of vision depending on its size, location and density. The condition is typically bilateral, seriously compromises visual acuity and contrast sensitivity and increases glare. Cataracts can also affect people at any age, however, they usually occur as a part of the natural aging process. The occurrence of cataracts increases with age from about 12% at age 50 years, to 60% at age 70. In general, approximately 50% of people 65 year of age or older have cataracts. Mild cataracts can be treated with a change in prescription glasses, while more serious symptoms are treated by surgical removal of the cataract and implantation of an IOL. In Ontario, the estimated prevalence of cataracts increased from 697,000 in 1992 to 947,000 in 2004 (35.9% increase, 2.4% annual increase). The number of cataract surgeries per 1,000 individuals at risk of cataract increased from 64.6 in 1992 to 140.4 in 1997 (61.9% increase, 10.1% annual increase) and continued to steadily increase to 115.7 in 2004 (10.7% increase, 5.2% increase per year). Description of Technology/Therapy IOLs are classified either as monofocal, multifocal, or accommodative. Traditionally, monofocal (i.e.. fixed focusing power) IOLs are available as replacement lenses but their implantation can cause a loss of the eye’s accommodative capability (which allows variable focusing). Patients thus usually require eyeglasses after surgery for reading and near vision tasks. Multifocal IOLs aim to improve near and distant vision and obviate the need for glasses. Potential disadvantages include reduced contrast sensitivity, halos around lights and glare. Accommodating IOLs are designed to move with ciliary body contraction during accommodation and, therefore, offer a continuous range of vision (i.e. near, intermediate and distant vision) without the need for glasses. Purported advantages over multifocal IOLs include the avoidance of haloes and no reduction in contrast sensitivity. Polymethyl methacrylate (PMMA) was the first material used in the fabrication of IOLs and has inherent ultraviolet blocking abilities. PMMA IOLs are inflexible, however, and require a larger incision for implantation compared with newer foldable silicone (hydrophobic) and acrylic (hydrophobic or hydrophilic) lenses. IOLs can be further sub-classified as being either aspheric or spheric, blue/violet filtered or non-filtered or 1- or 3-piece. Methods of Evidence-Based Analysis A literature search was conducted from January 2003 to January 2009 that included OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), The Cochrane Library, and the International Agency for Health Technology Assessment/Centre for Review and Dissemination. Inclusion Criteria Exclusion Criteria adult patients with age-related cataractssystematic reviews, randomized controlled trials (RCTs)primary outcomes: distance visual acuity (best corrected distance visual acuity), near visual acuity (best distance corrected near visual acuity)secondary outcomes: contrast sensitivity, depth of field, glare, quality of life, visual function, spectacle dependence, posterior capsule opacification. studies with fewer than 20 eyesIOLs for non-age related cataractsIOLs for presbyopiastudies with a mean follow-up <6monthsstudies reporting insufficient data for analysis Comparisons of Interest The primary comparison of interest was accommodative vs. multifocal vs. monofocal lenses. Secondary comparisons of interest included: tinted vs. non-tinted lenses aspheric vs. spheric lenses multipiece vs. single piece lenses biomaterial A (e.g. acrylic) vs. biomaterial B (e.g. silicone) lenses sharp vs. round edged lenses The quality of the studies was examined according to the GRADE Working Group criteria for grading quality of evidence for interventional procedures. Summary of Findings The conclusions of the systematic review of IOLs for age-related cataracts are summarized in Executive Summary Table 1. Considerations for the Ontario Health System Procedures for crystalline lens removal and IOL insertion are insured and listed in the Ontario Schedule of Benefits. If a particular lens is determined to be medically necessary for a patient, the cost of the lens is covered by the hospital budget. If the patient chooses a lens that has enhanced features, then the hospital may choose to charge an additional amount above the cost of the usual lens offered. An IOL manufacturer stated that monofocal lenses comprise approximately 95% of IOL sales in Ontario and premium lenses (e.g., multifocal/accomodative) consist of about 5% of IOL sales. A medical consultant stated that all types of lenses are currently being used in Ontario (e.g., multifocal, monofocal, accommodative, tinted, nontinted, spheric, and aspheric). Nonfoldable lenses, rarely used in routine cases, are primarily used for complicated cataract implantation situations. ES Table 1: Conclusions for the Systematic Review of IOLs for Age-Related Cataracts Comparison Conclusion GRADE Quality Multifocal vs. monofocal Objective OutcomesSignificant improvement in BDCUNVANo significant difference in BCDVAInconclusive evidence for contrast sensitivityInconclusive evidence for glareSubjective OutcomesInconclusive evidence for visual satisfactionSignificant increase in glare/halosSignificant increase in freedom from spectacles moderatemoderatelowvery lowlowlow/moderatelow/moderate Accommodative vs. multifocal/monofocal Inconclusive due to Insufficient limited evidence for any effectiveness outcome very low Hydrophilic acrylic vs. other materials (hydrophobic acrylic, silicone) Significant increase in PCO score Low Sharp edged compared to round edged Significant reduction in PCO score Low One piece compared to three piece No significant difference in PCO score low Hydrophobic acrylic compared to silicone No significant difference in PCO score moderate Aspherical modified prolate anterior surface compared to spherical No significant difference in VASignificant reduction in contrast sensitivity very lowvery low Blue light filtering compared to non blue-light filtering No significant difference in BCDVANo significant difference in contrast sensitivityNo significant difference in HRQL lowlowhigh/moderate BCDVA refers to best corrected distance visual acuity; BDCUNVA, best distance corrected unaided near visual acuity; HRQL, health related quality of life; PCO, posterior capsule opacification; VA, visual acuity. PMID:23074519

  9. Increased internal higher-order aberrations as a useful parameter for indication of vitrectomy in three asteroid hyalosis cases

    PubMed Central

    Yokoyama, Sho; Kojima, Takashi; Kaga, Tatsushi; Ichikawa, Kazuo

    2015-01-01

    We report three asteroid hyalosis cases in which internal higher-order aberrations (HOAs) were improved concomitant with improved visual symptoms after vitrectomy. Cases 1 and 2 reported severe floaters and glare disability, although their visual acuities were fairly good. Case 3 showed poor visual acuity since this patient also suffered from mild macular degeneration. For these three asteroid hyalosis cases, we were unsure if treatment with vitrectomy could improve visual symptoms. Therefore, we measured internal HOAs with an aberrometer, and found that the internal HOA values in these cases were high. We suspected that internal high HOAs values were associated with visual disturbance, and performed vitrectomy. After the vitrectomy, the internal HOA values in these three asteroid hyalosis cases markedly decreased, and visual symptoms improved. These observations suggested that measurement of internal HOAs may be useful to determine the indication for vitrectomy. PMID:26698200

  10. Mimicking cataract-induced visual dysfunction by means of protein denaturation in egg albumen

    NASA Astrophysics Data System (ADS)

    Mandracchia, B.; Finizio, A.; Ferraro, P.

    2016-03-01

    As the world's population ages, cataract-induced visual dysfunction and blindness is on the increase. This is a significant global problem. The most common symptoms of cataracts are glared and blurred vision. Usually, people with cataract have trouble seeing and reading at distance or in low light and also their color perception is altered. Furthermore, cataract is a sneaky disease as it is usually a very slow but progressive process, which creates adaptation so that patients find it difficult to recognize. All this can be very difficult to explain, so we built and tested an optical device to help doctors giving comprehensive answers to the patients' symptoms. This device allows visualizing how cataract impairs vision mimicking the optical degradation of the crystalline related cataracts. This can be a valuable optical tool for medical education as well as to provide a method to illustrate the patients how cataract progression process will affect their vision.

  11. Fixed mydriatic pupil associated with an intraocular pressure rise as a complication of the implant of a Phakic Refractive Lens (PRL).

    PubMed

    Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro

    2014-07-01

    We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.

  12. Environmental and economic analysis of end of life management options for an HDPE product using a life cycle thinking approach.

    PubMed

    Simões, Carla L; Pinto, Lígia M Costa; Bernardo, C A

    2014-05-01

    Manufacturers have been increasingly considering the implication of materials used in commercial products and the management of such products at the end of their useful lives (as waste or as post-consumer secondary materials). The present work describes the application of the life cycle thinking approach to a plastic product, specifically an anti-glare lamellae (used for road safety applications) made with high-density polyethylene (HDPE). This study shows that optimal environmental and economic outcomes associated with this product can be realized by recovering the material at the end of its useful life (end of life, EoL) and by using the recycled HDPE as a raw material in the production of new similar products. The study confirmed the applicability of the life cycle thinking approach by industry in sustainable products development, supporting the development of robust environmental and economic guidelines.

  13. Closing the "Know-Do" Gap: eHealth Strategies for the Global South.

    PubMed

    2008-01-01

    For years, the Internet has been the new black, the "in" thing, the must have. And the virtual fever is spreading. According to the World Bank, global Internet use more than quadrupled between 2000 and 2005, from 15 users per 1000 population to 67.[1] Yet, many Global South countries are stalled on the Information Superhighway: the same World Bank report found that only 15 per 1000 population in sub-Saharan Africa are connected to the Internet, and only 21 per1000 in South Asia. To say nothing of glaring access inequalities within countries, lack of foreign investment in the communications sector of developing nations, and deficient connectivity in key areas of national infrastructure - schools, government centers, and health facilities. Yet the same World Bank report noted that eHealth initiatives ranked last in a list of technology strategies among countries surveyed.[1].

  14. Why Tsallis statistics?

    NASA Astrophysics Data System (ADS)

    Baranger, Michel

    2002-03-01

    It is a remarkable fact that the traditional teaching of thermodynamics, as reflected in the textbooks and including the long developments about ensembles and thermodynamic functions, is almost entirely about systems in equilibrium. The time variable does not enter. There is one exception, however. The single most important item, the flagship of the thermodynamic navy, the second law, is about the irreversibility of the time evolution of systems out of equilibrium. This is a bizarre situation, to say the least; a glaring case of the drunk man looking for his key under the lamp-post, when he knows that he lost it in the dark part of the street. The moment has come for us to go looking in the dark part, the behavior of systems as a function of time. We have been given a powerful new flashlight, chaos theory. We should use it. There, on the formerly dark pavement, we can find Tsallis statistics.

  15. Peteye detection and correction

    NASA Astrophysics Data System (ADS)

    Yen, Jonathan; Luo, Huitao; Tretter, Daniel

    2007-01-01

    Redeyes are caused by the camera flash light reflecting off the retina. Peteyes refer to similar artifacts in the eyes of other mammals caused by camera flash. In this paper we present a peteye removal algorithm for detecting and correcting peteye artifacts in digital images. Peteye removal for animals is significantly more difficult than redeye removal for humans, because peteyes can be any of a variety of colors, and human face detection cannot be used to localize the animal eyes. In many animals, including dogs and cats, the retina has a special reflective layer that can cause a variety of peteye colors, depending on the animal's breed, age, or fur color, etc. This makes the peteye correction more challenging. We have developed a semi-automatic algorithm for peteye removal that can detect peteyes based on the cursor position provided by the user and correct them by neutralizing the colors with glare reduction and glint retention.

  16. Computer-implemented system and method for automated and highly accurate plaque analysis, reporting, and visualization

    NASA Technical Reports Server (NTRS)

    Kemp, James Herbert (Inventor); Talukder, Ashit (Inventor); Lambert, James (Inventor); Lam, Raymond (Inventor)

    2008-01-01

    A computer-implemented system and method of intra-oral analysis for measuring plaque removal is disclosed. The system includes hardware for real-time image acquisition and software to store the acquired images on a patient-by-patient basis. The system implements algorithms to segment teeth of interest from surrounding gum, and uses a real-time image-based morphing procedure to automatically overlay a grid onto each segmented tooth. Pattern recognition methods are used to classify plaque from surrounding gum and enamel, while ignoring glare effects due to the reflection of camera light and ambient light from enamel regions. The system integrates these components into a single software suite with an easy-to-use graphical user interface (GUI) that allows users to do an end-to-end run of a patient record, including tooth segmentation of all teeth, grid morphing of each segmented tooth, and plaque classification of each tooth image.

  17. Real time eye tracking using Kalman extended spatio-temporal context learning

    NASA Astrophysics Data System (ADS)

    Munir, Farzeen; Minhas, Fayyaz ul Amir Asfar; Jalil, Abdul; Jeon, Moongu

    2017-06-01

    Real time eye tracking has numerous applications in human computer interaction such as a mouse cursor control in a computer system. It is useful for persons with muscular or motion impairments. However, tracking the movement of the eye is complicated by occlusion due to blinking, head movement, screen glare, rapid eye movements, etc. In this work, we present the algorithmic and construction details of a real time eye tracking system. Our proposed system is an extension of Spatio-Temporal context learning through Kalman Filtering. Spatio-Temporal Context Learning offers state of the art accuracy in general object tracking but its performance suffers due to object occlusion. Addition of the Kalman filter allows the proposed method to model the dynamics of the motion of the eye and provide robust eye tracking in cases of occlusion. We demonstrate the effectiveness of this tracking technique by controlling the computer cursor in real time by eye movements.

  18. [Working conditions for supermarket employees: from experimental data to best practices].

    PubMed

    Martellotta, Francesco; Della Crociata, Sabrina; Simone, Antonio; Calderoni, Leonardo; D'Alba, Michele; Cervellati, Massimo; Papapietro, Nunzio

    2014-07-15

    Thermal, acoustic and visual comfort conditions for hypermarket workers have never been investigated with scientific methods. taking advantage of a case study, with characteristics capable of generalizing the results, analytically measure the actual comfort conditions to which workers are exposed and point out possible ameliorative proposals. Carry out a detailed survey based on instrumental measurements combined with subjective questionnaires to assess the indoor environment. Even though the analysis pointed out no significant risk conditions, several smaller problems appeared in terms of local discomfort (such as cold limbs, higher sound level exposure, limited glare phenomena) for cashier workers. The origin of these problems appeared to be the pivotal position of the cash registers. Taking into account observed phenomena and their causes a list of "best practices" has been defined hoping that their adoption could further limit any impact on workers comfort conditions.

  19. Design and analysis of reflector for uniform light-emitting diode illuminance.

    PubMed

    Tsai, Chung-Yu

    2013-05-01

    A light-emitting diode (LED) projection system is proposed, composed of an LED chip and a variable-focus-parabolic (VFP) reflector, in which the focal length varies as a function of the vertical displacement of the incidence point relative to the horizontal centerline of the LED chip. The light-ray paths within the projection system are analyzed using an exact analytical model and a skew-ray tracing approach. The profile of the proposed VFP reflector and the position of the LED chip are then optimized in such a way as to enhance the uniformity of the illuminance distribution on the target region of the image plane. The validity of the optimized design is demonstrated by means of ZEMAX simulations. It is shown that the optimized VFP projector system yields a significant improvement in illuminance uniformity compared to conventional spherical and parabolic projectors and therefore minimizes the glare effect.

  20. Quality of vision in refractive and cataract surgery, indirect measurers: review article.

    PubMed

    Parede, Taís Renata Ribeira; Torricelli, André Augusto Miranda; Mukai, Adriana; Vieira Netto, Marcelo; Bechara, Samir Jacob

    2013-01-01

    Visual acuity is the measurement of an individual's ability to recognize details of an object in a space. Visual function measurements in clinical ophthalmology are limited by factors such as maximum contrast and so it might not adequately reflect the real vision conditions at that moment as well as the subjective aspects of the world perception by the patient. The objective of a successful vision-restoring surgery lies not only in gaining visual acuity lines, but also in vision quality. Therefore, refractive and cataract surgeries have the responsibility of achieving quality results. It is difficult to define quality of vision by a single parameter, and the main functional-vision tests are: contrast sensitivity, disability glare, intraocular stray light and aberrometry. In the current review the different components of the visual function are explained and the several available methods to assess the vision quality are described.

  1. Daylighting as a design and energy strategy: Overview of opportunities and conflicts

    NASA Astrophysics Data System (ADS)

    Selkowitz, S.

    1981-06-01

    The potentials and problems associated with using daylight both to improve visual performance and interior aesthetics and to reduce electrical lighting energy consumption and peak electric loads are reviewed. Use of daylighting as a design strategy is not always synonymous with effective use of daylighting as an energy-saving strategy unless both approaches are jointly pursued by the design team. Criteria for visual performance, disability and discomfort glare, historical perspectives on daylight utilization, building form as a limit to daylight penetration, beam sunlighting strategies, luminous efficacy of daylight versus efficient electric light sources, comparative thermal impacts, peak load and load management potential, and nonenergy benefits are reviewed. Although the energy benefits of daylighting can be oversold, it is concluded that in most cases a solid understanding of the energy and design issues should produce energy efficiency and pleasing working environments.

  2. The Visual Effects of Intraocular Colored Filters

    PubMed Central

    Hammond, Billy R.

    2012-01-01

    Modern life is associated with a myriad of visual problems, most notably refractive conditions such as myopia. Human ingenuity has addressed such problems using strategies such as spectacle lenses or surgical correction. There are other visual problems, however, that have been present throughout our evolutionary history and are not as easily solved by simply correcting refractive error. These problems include issues like glare disability and discomfort arising from intraocular scatter, photostress with the associated transient loss in vision that arises from short intense light exposures, or the ability to see objects in the distance through a veil of atmospheric haze. One likely biological solution to these more long-standing problems has been the use of colored intraocular filters. Many species, especially diurnal, incorporate chromophores from numerous sources (e.g., often plant pigments called carotenoids) into ocular tissues to improve visual performance outdoors. This review summarizes information on the utility of such filters focusing on chromatic filtering by humans. PMID:24278692

  3. The Shuttle Mission Simulator computer generated imagery

    NASA Technical Reports Server (NTRS)

    Henderson, T. H.

    1984-01-01

    Equipment available in the primary training facility for the Space Transportation System (STS) flight crews includes the Fixed Base Simulator, the Motion Base Simulator, the Spacelab Simulator, and the Guidance and Navigation Simulator. The Shuttle Mission Simulator (SMS) consists of the Fixed Base Simulator and the Motion Base Simulator. The SMS utilizes four visual Computer Generated Image (CGI) systems. The Motion Base Simulator has a forward crew station with six-degrees of freedom motion simulation. Operation of the Spacelab Simulator is planned for the spring of 1983. The Guidance and Navigation Simulator went into operation in 1982. Aspects of orbital visual simulation are discussed, taking into account the earth scene, payload simulation, the generation and display of 1079 stars, the simulation of sun glare, and Reaction Control System jet firing plumes. Attention is also given to landing site visual simulation, and night launch and landing simulation.

  4. Bio-inspired, colorful, flexible, defrostable light-scattering hybrid films for the effective distribution of LED light.

    PubMed

    An, Seongpil; Jo, Hong Seok; Kim, Yong Il; Song, Kyo Yong; Kim, Min-Woo; Lee, Kyu Bum; Yarin, Alexander L; Yoon, Sam S

    2017-07-06

    Bioluminescent jellyfish has a unique structure derived from fiber/polymer interfaces that is advantageous for effective light scattering in the dark, deep sea water. Herein, we demonstrate the fabrication of bio-inspired hybrid films by mimicry of the jellyfish's structure, leading to excellent light-scattering performance and defrosting capability. A haze value reaching 59.3% and a heating temperature of up to 292 °C were achieved with the films. Accordingly, the developed surface constitutes an attractive optical device for lighting applications, especially for street or vehicle luminaries for freezing Arctic-climate countries. The morphological details of the hybrid films were revealed by scanning electron microscopy. The light-scattering properties of these films were examined by ultraviolet-visible-infrared spectrophotometry and anti-glare effect analyses. The defrosting performance of the hybrid films was evaluated via heating tests and infra-red observations.

  5. Solar radiation control using nematic curvilinear aligned phase (NCAP) liquid crystal technology

    NASA Astrophysics Data System (ADS)

    vanKonynenburg, Peter; Marsland, Stephen; McCoy, James

    1987-11-01

    A new, advanced liquid crystal technology has made economical, large area, electrically-controlled windows a commercial reality. The new technology, Nematic Curvilinear Aligned Phase (NCAP), is based on a polymeric material containing small droplets of nematic liquid crystal which is coated and laminated between transparent electrodes and fabricated into large area field effect devices. NCAP windows feature variable solar transmission and reflection through a voltage-controlled scattering mechanism. Laminated window constructions provide the excellent transmission and visibility of glass in the powered condition. In the unpowered condition, the windows are highly translucent, and provide 1) blocked vision for privacy, security, and obscuration of information, and 2) glare control and solar shading. The stability is excellent during accelerated aging tests. Degradation mechanisms which can limit performance and lifetime are discussed. Maximum long term stability is achieved by product designs that incorporate the appropriate window materials to provide environmental protection.

  6. On the Totality of the Eclipse in AD 628 in the Nihongi

    NASA Astrophysics Data System (ADS)

    Tanikawa, Kiyotaka; Sôma, Mitsuru

    2004-02-01

    It is widely accepted that the solar eclipse on AD 628 April 10 (the reign of Empress Suiko, 36th year, 3rd month, 2nd day) recorded in the Nihongi (****) was not total, but partial at the site of observation, though it is written as an exhausted eclipse. A contemporary Japanese occultation observation on AD 681 November 3 is also suspected as being a missing of Mars in the glaring light of the Moon. We suggest in this paper that both records in the Nihongi may be true. Several reasonings are put forward. We then point out the possibility that the value of ΔT at around AD 600 is about 2000s which is far less than 4500s, the value adopted by Stephenson (1997, Historical Eclipses and Earth's Rotation). Lunar grazing occultation data are found to be very useful.

  7. [Spinocerebellar ataxia type 2 associated to pigmentary retinitis].

    PubMed

    Jiménez-Caballero, Pedro Enrique; Serviá, Mónica

    2010-07-01

    Ocular disorders are useful in the characterisation of the different types of spinocerebellar ataxias (SCA); pigmentary retinitis is an alteration that is specifically associated to SCA type 7 and is characterised by night blindness, sensitivity to glare and progressive narrowing of the visual field. A 34-year-old woman with clinical symptoms of progressive ataxia and visual impairment secondary to pigmentary retinitis. The patient had a personal history with an autosomal dominant pattern of a similar disorder in her father and paternal grandmother. In the genetic study she presented a triplet expansion in the SCA type 2 gene. CONCLUSIONS; Although pigmentary retinitis belongs to the SCA type 7 phenotype, our patient presented this retinal disorder, as in other cases of SCA type 2. A genetic study for SCA type 2 must therefore be conducted in patients with a degenerative ataxic clinical picture and who present evidence of pigmentary retinitis.

  8. Increased internal higher-order aberrations as a useful parameter for indication of vitrectomy in three asteroid hyalosis cases.

    PubMed

    Yokoyama, Sho; Kojima, Takashi; Kaga, Tatsushi; Ichikawa, Kazuo

    2015-12-23

    We report three asteroid hyalosis cases in which internal higher-order aberrations (HOAs) were improved concomitant with improved visual symptoms after vitrectomy. Cases 1 and 2 reported severe floaters and glare disability, although their visual acuities were fairly good. Case 3 showed poor visual acuity since this patient also suffered from mild macular degeneration. For these three asteroid hyalosis cases, we were unsure if treatment with vitrectomy could improve visual symptoms. Therefore, we measured internal HOAs with an aberrometer, and found that the internal HOA values in these cases were high. We suspected that internal high HOAs values were associated with visual disturbance, and performed vitrectomy. After the vitrectomy, the internal HOA values in these three asteroid hyalosis cases markedly decreased, and visual symptoms improved. These observations suggested that measurement of internal HOAs may be useful to determine the indication for vitrectomy. 2015 BMJ Publishing Group Ltd.

  9. Visual symptoms and retinal straylight after laser peripheral iridotomy: the Zhongshan Angle-Closure Prevention Trial.

    PubMed

    Congdon, Nathan; Yan, Xixi; Friedman, David S; Foster, Paul J; van den Berg, Thomas J T P; Peng, Michelle; Gangwani, Rita; He, Mingguang

    2012-07-01

    To assess the impact of laser peripheral iridotomy (LPI) on forward-scatter of light and subjective visual symptoms and to identify LPI parameters influencing these phenomena. Cohort study derived from a randomized trial, using an external control group. Chinese subjects initially aged 50 or older and 70 years or younger with bilateral narrow angles undergoing LPI in 1 eye selected at random, and age- and gender-matched controls. Eighteen months after laser, LPI-treated subjects underwent digital iris photography and photogrammetry to characterize the size and location of the LPI, Lens Opacity Classification System III cataract grading, and measurement of retinal straylight (C-Quant; OCULUS, Wetzlar, Germany) in the treated and untreated eyes and completed a visual symptoms questionnaire. Controls answered the questionnaire and underwent straylight measurement and (in a random one-sixth sample) cataract grading. Retinal straylight levels and subjective visual symptoms. Among 230 LPI-treated subjects (121 [58.8%] with LPI totally covered by the lid, 43 [19.8%] with LPI partly covered by the lid, 53 [24.4%] with LPI uncovered by the lid), 217 (94.3%) completed all testing, as did 250 (93.3%) of 268 controls. Age, gender, and prevalence of visual symptoms did not differ between treated subjects and controls, although nuclear (P<0.01) and cortical (P = 0.03) cataract were less common among controls. Neither presenting visual acuity nor straylight score differed between the treated and untreated eyes among all treated persons, nor among those (n = 96) with LPI partially or totally uncovered. Prevalence of subjective glare did not differ significantly between participants with totally covered LPI (6.61%; 95% confidence interval [CI], 3.39%-12.5%), partially covered LPI (11.6%; 95% CI, 5.07%-24.5%), or totally uncovered LPI (9.43%; 95% CI, 4.10%-10.3%). In regression models, only worse cortical cataract grade (P = 0.01) was associated significantly with straylight score, and no predictors were associated with subjective glare. None of the LPI size or location parameters were associated with straylight or subjective symptoms. These results suggests that LPI is safe regarding measures of straylight and visual symptoms. This randomized design provides strong evidence that treatment programs for narrow angles would be unlikely to result in important medium-term visual disability. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. The (lack of) relation between straylight and visual acuity. Two domains of the point-spread-function.

    PubMed

    van den Berg, Thomas J T P

    2017-05-01

    The effect of cataract and other media opacities on functional vision is typically assessed clinically using visual acuity. In both clinical and basic research, straylight (the functional result of light scattering in the eye) is commonly measured. The purpose of the present study was to determine the link between these two measures: is visual acuity in cataract and other media opacities related to straylight? Interdependence between acuity and straylight is addressed from three different points of view: (1) Methodological: can acuity differences affect the measurement value of straylight, and vice versa? (2) Basic optics: does the optical process of light scattering in the human eye affect both straylight and visual acuity? (3) Statistical: how strongly are acuity and straylight correlated in the practice of important clinical conditions? Experimental and theoretical aspects will be considered, with a focus on normal ageing and cataract formation. (1) Methodological: testing potential effects of acuity, artificially manipulated with positive trial lenses, showed no effect on measured straylight values. Since light scattering in the eye involves a low percentage of the light and has large angular spreading, contrast reduction due to straylight is limited, resulting in virtually absent acuity effects. (2) Basic optics: light scattering from the human donor eye lens is found to have virtually no effect in the centre of the point-spread-function, also for cataractous lenses, resulting in virtually absent acuity effects. (3) Statistical: literature data on straylight and visual acuity show a weak correlation for the important groups of normal ageing and cataract populations. The point-spread-function of the normal ageing and cataractous human eye is built upon two rather independent basic parts. Aberrations control the central peak. Light scattering controls the periphery from about 1° onwards. The way acuity and straylight are measured ensures no confounding between them. Statistically within the normal ageing and cataract populations, visual acuity and straylight vary quite independently from each other. Visual acuity losses with cataract and other media opacities are not due to straylight, but caused by aberrations and micro-aberrations. Straylight defines disability glare, and causes symptoms of glare, haloes, hazy vision etc. Overall, visual acuity and straylight are rather independent aspects of quality of vision. © 2017 The Author Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  11. [The vision of welders in France].

    PubMed

    Boissin, J P; Peyresblanques, J; Rollin, J P; Marini, F; Beaufils, D

    2002-10-01

    A study was conducted to measure the impact of welding on the vision of welders. This study was conducted in France by the occupational medicine staff of large companies on 1.131 people, namely 850 welders and 281 control subjects. This investigation included two examinations at the beginning and the end of a year. The investigative procedure examined the different welding processes, the percentage of working time spent on welding activity, the length of exposure in years, as well as the medical variables: the optical correction type and history of ocular traumatology. The Visiotest or the Ergovision were used for the visual examination, equipment in common use by occupational medicine departments. The welders were comparatively young (59.53% of them were less than 45 years old). Moreover, for 69.75% of the welders, more than 75% of their activity was devoted to welding. All currently used welding processes were represented, including the modern PLASMA-TIG welding process. No excessive blood alcohol levels were observed in all subjects, but welders did smoke slightly more than the control subjects (40% vs 33%). Self-medication was rather less frequent among the welders, except as regards the use of eye drops, where the proportions were clearly inverted. Optical correction for hyperopia was similar between the two groups; however, as regards myopia, the welders were corrected less often. Lastly, contact lens use was exceptional among the welders. Nearsightedness varied logically with age, but also, inexplicably, with the welding processes. Vision recovery time after exposure to glare was much longer among the welders, except for the PLASMA-TIG processes. No difference was observed in the other parameters of the study. No change in the visual functions studied was noted between the two examinations. The examination techniques used showed no impairment of the studied visual functions, probably because companies use protective and preventive eye care methods. Moreover this study is the first to examine the type of welding used by workers and particularly the modern PLASMA-TIG process. The vision recovery time after exposure to glare seems better for the PLASMA-TIG process may be the result of the lower luminous intensity of this process. This study was conducted for preventive purposes to contribute to better monitoring of safety and comfort for welding workers and has shown no alteration of the visual function among welders in general.

  12. Impact of Oncoming Headlight Glare With Cataracts: A Pilot Study

    PubMed Central

    Hwang, Alex D.; Tuccar-Burak, Merve; Goldstein, Robert; Peli, Eli

    2018-01-01

    Purpose: Oncoming headlight glare (HLG) reduces the visibility of objects on the road and may affect the safety of nighttime driving. With cataracts, the impact of oncoming HLG is expected to be more severe. We used our custom HLG simulator in a driving simulator to measure the impact of HLG on pedestrian detection by normal vision subjects with simulated mild cataracts and by patients with real cataracts. Methods: Five normal vision subjects drove nighttime scenarios under two HLG conditions (with and without HLG: HLGY and HLGN, respectively), and three vision conditions (with plano lens, simulated mild cataract, and optically blurred clip-on). Mild cataract was simulated by applying a 0.8 Bangerter diffusion foil to clip-on plano lenses. The visual acuity with the optically blurred lenses was individually chosen to match the visual acuity with the simulated cataract clip-ons under HLGN. Each nighttime driving scenario contains 24 pedestrian encounters, encompassing four pedestrian types; walking along the left side of the road, walking along the right side of the road, crossing the road from left to right, and crossing the road from right to left. Pedestrian detection performances of five patients with mild real cataracts were measured using the same setup. The cataract patients were tested only in HLGY and HLGN conditions. Participants’ visual acuity and contrast sensitivity were also measured in the simulator with and without stationary HLG. Results: For normal vision subjects, both the presence of oncoming HLG and wearing the simulated cataract clip-on reduced pedestrian detection performance. The subjects performed worst in events where the pedestrian crossed from the left, followed by events where the pedestrian crossed from the right. Significant interactions between HLG condition and other factors were also found: (1) the impact of oncoming HLG with the simulated cataract clip-on was larger than with the plano lens clip-on, (2) the impact of oncoming HLG was larger with the optically blurred clip-on than with the plano lens clip-on, but smaller than with the simulated cataract clip-on, and (3) the impact was larger for the pedestrians that crossed from the left than those that crossed from the right, and for the pedestrians walking along the left side of the road than walking along the right side of the road, suggesting that the pedestrian proximity to the glare source contributed to the performance reduction. Under HLGN, almost no pedestrians were missed with the plano lens or the simulated cataract clip-on (0 and 0.5%, respectively), but under HLGY, the rate of pedestrian misses increased to 0.5 and 6%, respectively. With the optically blurred clip-on, the percent of missed pedestrians under HLGN and HLGY did not change much (5% and 6%, respectively). Untimely response rate increased under HLGY with the plano lens and simulated cataract clip-ons, but the increase with the simulated cataract clip-on was significantly larger than with the plano lens clip-on. The contrast sensitivity with the simulated cataract clip-on was significantly degraded under HLGY. The visual acuity with the plano lens clip-on was significantly improved under HLGY, possibly due to pupil myosis. The impact of HLG measured for real cataract patients was similar to the impact on performance of normal vision subjects with simulated cataract clip-ons. Conclusion: Even with mild (simulated or real) cataracts, a substantial negative effect of oncoming HLG was measurable in the detection of crossing and walking-along pedestrians. The lowered pedestrian detection rates and longer response times with HLGY demonstrate a possible risk that oncoming HLG poses to patients driving with cataracts. PMID:29559933

  13. Family social capital and health - a systematic review and redirection.

    PubMed

    Alvarez, Elena Carrillo; Kawachi, Ichiro; Romani, Jordi Riera

    2017-01-01

    The level (or scale) at which social capital can be conceptualised and measured ranges potentially from the macro-level (regional or country level), to the meso-level (neighbourhoods, workplaces, schools), down to the individual level. However, one glaring gap in the conceptualisation of social capital within the empirical literature has been the level of the family. Our aim in this review is to examine the family as the 'missing level' in studies on social capital and health. To do so, we conducted a systematic review on the use and measurement of this notion in the health literature, with the final intention of articulating a direction for future research in the field. Our findings are consistent with the notion that family social capital is multidimensional and that its components have distinct effects on health outcomes. Further investigation is needed to understand the mechanisms through which family social capital is related to health, as well as determining the most valid ways to measure family social capital. © 2016 Foundation for the Sociology of Health & Illness.

  14. Einstein, race, and the myth of the cultural icon

    NASA Astrophysics Data System (ADS)

    Jerome, Fred

    2004-12-01

    The most remarkable aspect of Einstein's 1946 address at Lincoln University is that it has vanished from Einstein's recorded history. Its disappearance into a historical black hole symbolizes what seems to happen in the creation of a cultural icon. It is but one of many political statements by Einstein to have met such a fate, though his civil rights activism is most glaringly mission. One explanation for this historical amnesia is that those who shape our official memories felt that Einstein's "controversial" friends like Paul Robeson and activities like co-chairing the anti-lynching crusade might tarnish Einstein as an icon. That icon, sanctified by Time magazine when it dubbed Einstein "Person of the Century" at the end of 1999, is a myth, albeit a marvelous one. Yet it is not so much the motive for the omission but the consequence of it that should concern us. Americans and the millions of Einstein fans around the world are left unaware that he was an outspoken, passionate, committed antiracist.

  15. [Multifocal intraocular lenses. A review].

    PubMed

    Auffarth, G U; Dick, H B

    2001-02-01

    Modern cataract surgery has developed tremendously during the past 10-15 years. Improved surgical techniques, as well as improved implant materials and designs, have enlarged patient profiles and indications for cataract surgery. This also created much higher expectations from the patients' site. The loss of accommodation is loss of quality of life for presbyopic and especially young pseudophakic patients. Therefore cataract surgery with multifocal IOL implantation is not only of academic interest, but reflects demands and expectations of our patients. Multifocal IOLs have been implanted since 1986, starting with 2-3 zone refractive and diffractive designs. Due to surgical techniques of that time MIOL decentration and surgically induced astigmatism were possible complications. In addition reduced contrast sensitivity and increased glare were common problems of MIOL because of their optical principles. New developments in this field in recent years such as the multizonal, progressive refractive MIOL in combination with improved surgical techniques have overcome those initial problems. Therefore, modern multifocal IOLs can be considered not only for correction of aphakia but also for refractive purposes.

  16. Investigation of a light fixture fire

    DOE PAGES

    Jurney, James D.; Cournoyer, Michael E.; Trujillo, Stanley; ...

    2016-04-16

    Metal-halide lamps produce light by discharging an electric arc through a gaseous mixture of vaporized mercury and metal halides. Metal-halide lamps for use in spaces with lower mounting heights can produce excessive visual glare in the normal, higher field-of-view unless they are equipped with prismatic lenses. Should the bulb fail, high internal operating pressure of the arc tube can launch fragments of arc tube at high velocity in all directions, striking the outer bulb of the lamp with enough force to cause the outer bulb to break. This article reports an investigation of a light fixture fire and reviews amore » case study of a metal-halide lamp fire. We reported on causal analysis of the metal-halide lamp fire uncovered contributing factors that created the environment in which the incident occurred. Latent organizational conditions that created error-likely situations or weakened defenses were identified and controlled. Lastly, effective improvements that reduce the probability or consequence of similar metal-halide lamp fire incidents were implemented.« less

  17. Preventive Medicine in Relation to Aviation

    PubMed Central

    Whittingham, H. E.

    1939-01-01

    Introduction—The progress of aviation. The protection of communities against diseases liable to be imported by aircraft. Relationship between the incubation period of infectious diseases and time taken by air journeys to distant lands. Administrative measures for the sanitary control of air-traffic:— The International Sanitary Convention for Aerial Navigation (1993). The role of the Office International d'Hygiène Publique, and the Health Organization of the League of Nations. The Public Health (Aircraft) Regulations, 1938. Types of aerodromes for sanitary purposes. Practical measures for the sanitary control of aerodromes and aircraft especially as regards insects, passengers, and freight. Possible transmission of yellow fever by aircraft: antimeasures, including vaccination. The protection of flying personnel against diseases due to flying. (a) Vision—glare; ocular fatigue of night and blind flying; blacking-out; night blindness. (b) Hearing — noise; aerial telephony; middle-ear deafness, and excessive vestibular stimulation. (c) Respiration—oxygen want. (d) Fatigue. (e) Digestion—ballooning of stomach; air-sickness; rations for long-distance flights; water supply. PMID:19991846

  18. Image acquisition device of inspection robot based on adaptive rotation regulation of polarizer

    NASA Astrophysics Data System (ADS)

    Dong, Maoqi; Wang, Xingguang; Liang, Tao; Yang, Guoqing; Zhang, Chuangyou; Gao, Faqin

    2017-12-01

    An image processing device of inspection robot with adaptive polarization adjustment is proposed, that the device includes the inspection robot body, the image collecting mechanism, the polarizer and the polarizer automatic actuating device. Where, the image acquisition mechanism is arranged at the front of the inspection robot body for collecting equipment image data in the substation. Polarizer is fixed on the automatic actuating device of polarizer, and installed in front of the image acquisition mechanism, and that the optical axis of the camera vertically goes through the polarizer and the polarizer rotates with the optical axis of the visible camera as the central axis. The simulation results show that the system solves the fuzzy problems of the equipment that are caused by glare, reflection of light and shadow, and the robot can observe details of the running status of electrical equipment. And the full coverage of the substation equipment inspection robot observation target is achieved, which ensures the safe operation of the substation equipment.

  19. Vision-aided Monitoring and Control of Thermal Spray, Spray Forming, and Welding Processes

    NASA Technical Reports Server (NTRS)

    Agapakis, John E.; Bolstad, Jon

    1993-01-01

    Vision is one of the most powerful forms of non-contact sensing for monitoring and control of manufacturing processes. However, processes involving an arc plasma or flame such as welding or thermal spraying pose particularly challenging problems to conventional vision sensing and processing techniques. The arc or plasma is not typically limited to a single spectral region and thus cannot be easily filtered out optically. This paper presents an innovative vision sensing system that uses intense stroboscopic illumination to overpower the arc light and produce a video image that is free of arc light or glare and dedicated image processing and analysis schemes that can enhance the video images or extract features of interest and produce quantitative process measures which can be used for process monitoring and control. Results of two SBIR programs sponsored by NASA and DOE and focusing on the application of this innovative vision sensing and processing technology to thermal spraying and welding process monitoring and control are discussed.

  20. Effect of dividing daylight in symmetric prismatic daylight collector

    NASA Astrophysics Data System (ADS)

    Yeh, Shih-Chuan; Lu, Ju-Lin; Cheng, Yu-Chin

    2017-04-01

    This paper presented a symmetric prismatic daylight collector to collect daylight for the natural light illumination system. We analyzed the characteristics of the emerging light when the parallel light beam illuminate on the horizontally placed symmetric prismatic daylight collector. The ratio of the relative intensities of collected daylight that emerging from each surface of the daylight collector shown that the ratio is varied with the incident angle during a day. The simulation of the emerging light of the daylight collector shown that the ratio of emerging light is varied with the tilted angle when sunshine illuminated on a symmetric prismatic daylight collector which was not placed horizontally. The integration of normalized intensity is also varied with the tilted angle. The symmetric prismatic daylight collector with the benefits of reducing glare and dividing intensity of incident daylight, it is applicable to using in the natural light illumination system and hybrid system for improving the efficiency of utilizing of solar energy.

  1. Apollo 12 Mission image - Lunar surface near lunar module

    NASA Image and Video Library

    1969-11-19

    AS12-47-6949 (19-20 Nov. 1969) --- A photograph of the Apollo 12 lunar landing site taken during the extravehicular activity (EVA) of astronauts Charles Conrad Jr., commander; and Alan L. Bean, lunar module pilot. The Apollo 12 Lunar Module (LM) is on the left. Barely visible in the center of the picture, in the shadows on the farside of the crater, is the Surveyor 3 spacecraft. The two spacecraft are about 600 feet apart. Conrad and Bean walked over to Surveyor 3 during their second EVA. The television camera and several other pieces were taken from Surveyor 3 and brought back to Earth for scientific examination. Astronaut Richard F. Gordon Jr., command module pilot, remained with the Command and Service Modules (CSM) in lunar orbit, while astronauts Conrad and Bean descended in the LM to explore the moon. The considerable glare in the picture is caused by the position of the sun. The Apollo tool carrier is the object next to the LM footpad.

  2. LCD-based digital eyeglass for modulating spatial-angular information.

    PubMed

    Bian, Zichao; Liao, Jun; Guo, Kaikai; Heng, Xin; Zheng, Guoan

    2015-05-04

    Using programmable aperture to modulate spatial-angular information of light field is well-known in computational photography and microscopy. Inspired by this concept, we report a digital eyeglass design that adaptively modulates light field entering human eyes. The main hardware includes a transparent liquid crystal display (LCD) and a mini-camera. The device analyzes the spatial-angular information of the camera image in real time and subsequently sends a command to form a certain pattern on the LCD. We show that, the eyeglass prototype can adaptively reduce light transmission from bright sources by ~80% and retain transparency to other dim objects meanwhile. One application of the reported device is to reduce discomforting glare caused by vehicle headlamps. To this end, we report the preliminary result of using the reported device in a road test. The reported device may also find applications in military operations (sniper scope), laser counter measure, STEM education, and enhancing visual contrast for visually impaired patients and elderly people with low vision.

  3. Investigation into Composites Property Effect on the Forming Limits of Multi-Layer Hybrid Sheets Using Hydroforming Technology

    NASA Astrophysics Data System (ADS)

    Liu, Shichen; Lang, Lihui; Guan, Shiwei; Alexandrov, Seigei; Zeng, Yipan

    2018-04-01

    Fiber-metal laminates (FMLs) such as Kevlar reinforced aluminum laminate (ARALL), Carbon reinforced aluminum laminate (CARALL), and Glass reinforced aluminum laminate (GLARE) offer great potential for weight reduction applications in automobile and aerospace construction. In order to investigate the feasibility for utilizing such materials in the form of laminates, sheet hydroforming technology are studied under the condition of uniform blank holder force for three-layered aluminum and aluminum-composite laminates using orthogonal carbon and Kevlar as well as glass fiber in the middle. The experimental results validate the finite element results and they exhibited that the forming limit of glass fiber in the middle is the highest among the studied materials, while carbon fiber material performs the worst. Furthermore, the crack modes are different for the three kinds of fiber materials investigated in the research. This study provides fundamental guidance for the selection of multi-layer sheet materials in the future manufacturing field.

  4. A Distant Solar System Artist Concept

    NASA Image and Video Library

    2004-12-09

    This artist concept depicts a distant hypothetical solar system, similar in age to our own. Looking inward from the system outer fringes, a ring of dusty debris can be seen, and within it, planets circling a star the size of our Sun. This debris is all that remains of the planet-forming disk from which the planets evolved. Planets are formed when dusty material in a large disk surrounding a young star clumps together. Leftover material is eventually blown out by solar wind or pushed out by gravitational interactions with planets. Billions of years later, only an outer disk of debris remains. These outer debris disks are too faint to be imaged by visible-light telescopes. They are washed out by the glare of the Sun. However, NASA's Spitzer Space Telescope can detect their heat, or excess thermal emission, in infrared light. This allows astronomers to study the aftermath of planet building in distant solar systems like our own. http://photojournal.jpl.nasa.gov/catalog/PIA07096

  5. Adverse Health Effects of Nighttime Lighting

    NASA Astrophysics Data System (ADS)

    Motta, M.

    2012-06-01

    The effects of poor lighting and glare on public safety are well-known, as are the harmful environmental effects on various species and the environment in general. What is less well-known is the potential harmful medical effects of excessive poor nighttime lighting. A significant body of research has been developed over the last few years regarding this problem. One of the most significant effects is the startling increased risk for breast cancer by excessive exposure to nighttime lighting. The mechanism is felt to be by disruption of the circadian rhythm and suppression of melatonin production from the pineal gland. Melatonin has an anticancer effect that is lost when its production is disrupted. I am in the process of developing a monograph that will summarize this important body of research, to be presented and endorsed by the American Medical Association, and its Council of Science and Public health. This paper is a brief overall summary of this little known potential harmful effect of poor and excessive nighttime lighting.

  6. Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital

    PubMed Central

    AlSabaani, Nasser A.; Behrens, Ashley; Jastanieah, Sabah; Al Malki, Salem; Al Jindan, Mohanna; Al Motowa, Saeed

    2016-01-01

    PURPOSE: The purpose of this study is to evaluate the causes of phakic implantable collamer lens (ICL) explantation/exchange at an eye hospital in Saudi Arabia. MATERIALS AND METHODS: A retrospective chart review was performed for patients who underwent ICL implantation from 2007 to March 2014 and data were collected on cases that underwent ICL explantation. RESULTS: Of the 787 ICL implants, 30 implants (3.8% [95% confidence interval 2.6%; 5.3%]) were explanted. The causes of explantation included incorrect lens size (22), cataract (4), high residual astigmatism (2), rhegmatogenous retinal detachment (1), and intolerable glare (1). Corrective measures mainly included an exchange with an appropriately sized lens (9), ICL explantation (11), with phacoemulsification and posterior chamber intraocular lens implantation (6), or replacement with an ICL of correct power (2). CONCLUSION: Incorrect ICL size was the most common cause of ICL explantation. More accurate sizing methods for ICL are required to reduce the explantation/exchange rate. PMID:27994391

  7. The implications of megatrends in information and communication technology and transportation for changes in global physical activity.

    PubMed

    Pratt, Michael; Sarmiento, Olga L; Montes, Felipe; Ogilvie, David; Marcus, Bess H; Perez, Lilian G; Brownson, Ross C

    2012-07-21

    Physical inactivity accounts for more than 3 million deaths per year, most from non-communicable diseases in low-income and middle-income countries. We used reviews of physical activity interventions and a simulation model to examine how megatrends in information and communication technology and transportation directly and indirectly affect levels of physical activity across countries of low, middle, and high income. The model suggested that the direct and potentiating eff ects of information and communication technology, especially mobile phones, are nearly equal in magnitude to the mean eff ects of planned physical activity interventions. The greatest potential to increase population physical activity might thus be in creation of synergistic policies in sectors outside health including communication and transportation. However, there remains a glaring mismatch between where studies on physical activity interventions are undertaken and where the potential lies in low-income and middle-income countries for population-level effects that will truly affect global health.

  8. A case of trauma related Acanthamoeba keratitis.

    PubMed

    Kamel, A G M; Faridah, H; Yusof, S; Norazah, A; Nakisah, M A

    2004-12-01

    Acanthamoeba is an uncommon cause of keratitis but one of the most severe because of the prolonged and painful course of the disease and poor visual outcome. Although contact lens use is the principal risk factor, about 10% of cases occur following trauma and exposure to contaminated soil or water. Two cases of Acanthamoeba keratitis involving women contact lens wearers have previously been reported in Malaysia but this is the first time, a non contact lens related Acanthamoeba keratitis is reported. The case involved a 28 year old Indonesian male construction worker who had a trauma of the right eye during work. His eye was struck by sand and dust particles after which he quickly washed with water from an open tank at the construction site. He experienced pain, redness, glaring and blurring of vision of the right eye three days later. The diagnosis was missed at initial presentation but culture of the corneal scraping had proven Acanthamoeba as the aetiological agent. The history and clinical findings of this trauma related Acanthamoeba keratitis are briefly discussed.

  9. Investigation of a light fixture fire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jurney, James D.; Cournoyer, Michael E.; Trujillo, Stanley

    Metal-halide lamps produce light by discharging an electric arc through a gaseous mixture of vaporized mercury and metal halides. Metal-halide lamps for use in spaces with lower mounting heights can produce excessive visual glare in the normal, higher field-of-view unless they are equipped with prismatic lenses. Should the bulb fail, high internal operating pressure of the arc tube can launch fragments of arc tube at high velocity in all directions, striking the outer bulb of the lamp with enough force to cause the outer bulb to break. This article reports an investigation of a light fixture fire and reviews amore » case study of a metal-halide lamp fire. We reported on causal analysis of the metal-halide lamp fire uncovered contributing factors that created the environment in which the incident occurred. Latent organizational conditions that created error-likely situations or weakened defenses were identified and controlled. Lastly, effective improvements that reduce the probability or consequence of similar metal-halide lamp fire incidents were implemented.« less

  10. The implications of megatrends in information and communication technology and transportation for changes in global physical activity

    PubMed Central

    Pratt, Michael; Sarmiento, Olga L; Montes, Felipe; Ogilvie, David; Marcus, Bess H; Perez, Lilian G; Brownson, Ross C

    2016-01-01

    Physical inactivity accounts for more than 3 million deaths per year, most from non-communicable diseases in low-income and middle-income countries. We used reviews of physical activity interventions and a simulation model to examine how megatrends in information and communication technology and transportation directly and indirectly affect levels of physical activity across countries of low, middle, and high income. The model suggested that the direct and potentiating effects of information and communication technology, especially mobile phones, are nearly equal in magnitude to the mean effects of planned physical activity interventions. The greatest potential to increase population physical activity might thus be in creation of synergistic policies in sectors outside health including communication and transportation. However, there remains a glaring mismatch between where studies on physical activity interventions are undertaken and where the potential lies in low-income and middle-income countries for population-level effects that will truly affect global health. PMID:22818940

  11. Generalized nonimaging compound elliptical and compound hyperbolic luminaire designs for pair-overlap illumination applications.

    PubMed

    Georlette, O; Gordon, J M

    1994-07-01

    Generalized nonimaging compound elliptical luminaires (CEL's) and compound hyperbolic luminaires (CHL's) are developed for pair-overlap illumination applications. A comprehensive analysis of CEL's and CHL's is presented. This includes the possibility of reflector truncation, as well as the extreme direction that spans the full range from positive to negative. Negative extreme direction devices have been overlooked in earlier studies and are shown to be well suited to illumination problems for which large cutoff angles are required. Flux maps can be calculated analytically without the need for computer ray tracing. It is demonstrated that, for a broad range of cutoff angles, adjacent pairs of CEL's and CHL's can generate highly uniform far-field illuminance while maintaining maximal lighting efficiency and excellent glare control. The trade-off between luminaire compactness and flux homogeneity is also illustrated. For V troughs, being a special case of CHL's and being well suited to simple, inexpensive fabri ation, we identify geometries that closely approach the performance characteristics of the optimized CEL's and CHL's.

  12. Transients in the Local Universe : Systematically Searching the Gap between Novae and Supernovae

    NASA Astrophysics Data System (ADS)

    Kasliwal, Mansi M.; Kulkarni, S.

    2009-05-01

    We present three systematic transient searches of the glaring luminosity gap between brightest novae (Mv = -10) and faintest supernovae (Mv = -16). The least explored regime in this gap, with several intriguing theoretical predictions, is short-duration transients (<10; days). Our searches are targeted and designed to be deeper and faster cadence (1-day) than traditional supernova searches and probe a larger volume compared to nova searches. We summarize discoveries from our search of the nearest, brightest galaxies (P60-FasTING, Fast Transients In Nearest Galaxies) and nearest galaxy clusters (CFHT-COVET, Coma and Virgo Exploration for Transients). We also highlight first results from the Palomar Transient Factory which targets local (<200 Mpc) luminosity concentrations. We suggest that building a complete inventory of transients in the local universe is timely. These transients are potential electromagnetic counterparts to next-generation instruments (e.g. Advanced LIGO, Auger, ICECUBE) which are also limited in sensitivity (due to intrumental or physical effects) to the local universe.

  13. Hiding in Plain Sight: The Low Mass Helium Star Companion of EL CVn

    NASA Astrophysics Data System (ADS)

    Gies, Douglas

    2016-10-01

    Binary stars with orbital periods of a decade or less are destined to interact during their evolution. The mass donor star among intermediate binaries may be stripped of its envelope by mass transfer to reveal its helium core. In cases that avoid merger, the low mass helium star will remain in a binary orbit but be lost in the glare of the mass gainer star.Thanks to photometric time series from Kepler and WASP, we now know of 27 such systems that are oriented to produce mutual eclipses. Althoughthe helium star companions are too small and faint in the optical bandfor spectroscopic detection, they contribute a larger fraction of the total flux in the ultraviolet. HST/COS measurements of one long period system, KOI-81, successfully detected the helium star's spectrum in the far-ultraviolet, leading to estimates of its mass and temperature. Here we propose to obtain new HST/COS FUV spectra of the prototype of this class of evolved binaries, EL CVn, and to determine the mass and physical properties of a star that barely escaped a merger.

  14. High color fidelity thin film multilayer systems for head-up display use

    NASA Astrophysics Data System (ADS)

    Tsou, Yi-Jen D.; Ho, Fang C.

    1996-09-01

    Head-up display is gaining increasing access in automotive vehicles for indication and position/navigation purposes. An optical combiner, which allows the driver to receive image information from outside and inside of the automobile, is the essential part of this display device. Two multilayer thin film combiner coating systems with distinctive polarization selectivity and broad band spectral neutrality are discussed. One of the coating systems was designed to be located at the lower portion of the windshield. The coating reduced the exterior glare by approximately 45% and provided about 70% average see-through transmittance in addition to the interior information display. The other coating system was designed to be integrated with the sunshield located at the upper portion of the windshield. The coating reflected the interior information display while reducing direct sunlight penetration to 25%. Color fidelity for both interior and exterior images were maintained in both systems. This facilitated the display of full-color maps. Both coating systems were absorptionless and environmentally durable. Designs, fabrication, and performance of these coating systems are addressed.

  15. Will musculoskeletal, visual and psychosocial stress change for visual display unit (VDU) operators when moving from a single-occupancy office to an office landscape?

    PubMed

    Helland, Magne; Horgen, Gunnar; Kvikstad, Tor Martin; Garthus, Tore; Aarås, Arne

    2008-01-01

    This study investigated the effect of moving from single-occupancy offices to a landscape environment. Thirty-two visual display unit (VDU) operators reported no significant change in visual discomfort. Lighting conditions and glare reported subjectively showed no significant correlation with visual discomfort. Experience of pain was found to reduce subjectively rated work capacity during VDU tasks. The correlation between visual discomfort and reduced work capacity for single-occupancy offices was rs=.88 (p=.000) and for office landscape rs=.82 (p=.000). Eye blink rate during habitual VDU work was recorded for 12 operators randomly selected from the 32 participants in the office landscape. A marked drop in eye blink rate during VDU work was found compared to eye blink rate during easy conversation. There were no significant changes in pain intensity in the neck, shoulder, forearm, wrist/hand, back or headache (.24

  16. The Pharmacological Effects of Lutein and Zeaxanthin on Visual Disorders and Cognition Diseases.

    PubMed

    Jia, Yu-Ping; Sun, Lei; Yu, He-Shui; Liang, Li-Peng; Li, Wei; Ding, Hui; Song, Xin-Bo; Zhang, Li-Juan

    2017-04-20

    Lutein (L) and zeaxanthin (Z) are dietary carotenoids derived from dark green leafy vegetables, orange and yellow fruits that form the macular pigment of the human eyes. It was hypothesized that they protect against visual disorders and cognition diseases, such as age-related macular degeneration (AMD), age-related cataract (ARC), cognition diseases, ischemic/hypoxia induced retinopathy, light damage of the retina, retinitis pigmentosa, retinal detachment, uveitis and diabetic retinopathy. The mechanism by which they are involved in the prevention of eye diseases may be due their physical blue light filtration properties and local antioxidant activity. In addition to their protective roles against light-induced oxidative damage, there are increasing evidences that L and Z may also improve normal ocular function by enhancing contrast sensitivity and by reducing glare disability. Surveys about L and Z supplementation have indicated that moderate intakes of L and Z are associated with decreased AMD risk and less visual impairment. Furthermore, this review discusses the appropriate consumption quantities, the consumption safety of L, side effects and future research directions.

  17. Photography in Dermatologic Surgery: Selection of an Appropriate Lighting Solution for a Particular Clinical Application.

    PubMed

    Chen, Brian R; Poon, Emily; Alam, Murad

    2018-01-01

    Lighting is an important component of consistent, high-quality dermatologic photography. There are different types of lighting solutions available. To evaluate currently available lighting equipment and methods suitable for procedural dermatology. Overhead lighting, built-in camera flashes, external flash units, studio strobes, and light-emitting diode (LED) light panels were evaluated with regard to their utility for dermatologic surgeons. A set of ideal lighting characteristics was used to examine the capabilities and limitations of each type of lighting solution. Recommendations regarding lighting solutions and optimal usage configurations were made in terms of the context of the clinical environment and the purpose of the image. Overhead lighting may be a convenient option for general documentation. An on-camera lighting solution using a built-in camera flash or a camera-mounted external flash unit provides portability and consistent lighting with minimal training. An off-camera lighting solution with studio strobes, external flash units, or LED light panels provides versatility and even lighting with minimal shadows and glare. The selection of an optimal lighting solution is contingent on practical considerations and the purpose of the image.

  18. Framework for hyperspectral image processing and quantification for cancer detection during animal tumor surgery.

    PubMed

    Lu, Guolan; Wang, Dongsheng; Qin, Xulei; Halig, Luma; Muller, Susan; Zhang, Hongzheng; Chen, Amy; Pogue, Brian W; Chen, Zhuo Georgia; Fei, Baowei

    2015-01-01

    Hyperspectral imaging (HSI) is an imaging modality that holds strong potential for rapid cancer detection during image-guided surgery. But the data from HSI often needs to be processed appropriately in order to extract the maximum useful information that differentiates cancer from normal tissue. We proposed a framework for hyperspectral image processing and quantification, which includes a set of steps including image preprocessing, glare removal, feature extraction, and ultimately image classification. The framework has been tested on images from mice with head and neck cancer, using spectra from 450- to 900-nm wavelength. The image analysis computed Fourier coefficients, normalized reflectance, mean, and spectral derivatives for improved accuracy. The experimental results demonstrated the feasibility of the hyperspectral image processing and quantification framework for cancer detection during animal tumor surgery, in a challenging setting where sensitivity can be low due to a modest number of features present, but potential for fast image classification can be high. This HSI approach may have potential application in tumor margin assessment during image-guided surgery, where speed of assessment may be the dominant factor.

  19. ARC-1989-A89-7045

    NASA Image and Video Library

    1989-08-26

    Range : 280,000 km. ( 170,000 miles ) P-34726 BW Two 10 minute exposures of Neptune's rings clearly show the two main rings , as well as the inner faint ring and the faint band that extends planetward from roughly halfway between the two bright rings. Both bright rings have material throughout their entire orbit, and are therefore continuous. The inner ring and the broad band are much fainter than the two narrow main rings. These images were taken 1 hour and 27 minutes aprt, using the clear filter on Voyager 2's wide angle camera. These long exposures images were taken while the rings were backlit by the sun. This viewing geometry enhances the visibility of dust and allows optically thinner parts of the rings to be seen. The bright glare in the center is due to overexposure of the crescent of Neptune . The two gaps in the upper part of the outer ring in the image on the left are due to the removal of blemishes during computer processing of the images. Numerous bright stars are evident in the background.

  20. [Clinical results after implantation of a new segmental refractive multifocal intraocular lens].

    PubMed

    Thomas, B C; Auffarth, G U; Philips, R; Novák, J; Blazek, J; Adamkova, H; Rabsilber, T M

    2013-11-01

    The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study. In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated. The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare. This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.

  1. Design evaluation in technology assessment: Illustrated by auditory impedance and sound distribution problems

    NASA Technical Reports Server (NTRS)

    Halldane, J. F.

    1972-01-01

    Technology is considered as a culture for changing a physical world and technology assessment questions the inherent cultural capability to modify power and material in support of living organisms. A comprehensive goal-parameter-synthesis-criterion specification is presented as a basis for a rational assessment of technology. The thesis queries the purpose of the assessed problems, the factors considered, the relationships between factors, and the values assigned those factors to accomplish the appropriate purpose. Stationary and sequential evaluation of enviro-organismic systems are delegated to the responsible personalities involved in design; from promoter/designer through contractor to occupant. Discussion includes design goals derived from organismic factors, definitions of human responses which establish viable criteria and relevant correlation models, linking stimulus parameters, and parallel problem-discipline centered design organization. A consistent concept of impedance, as a degradation in the performance of a specified parameter, is introduced to overcome the arbitrary inoperative connotations of terms like noise, discomfort, and glare. Applications of the evaluative specification are illustrated through design problems related to auditory impedance and sound distribution.

  2. Simultaneous Feulgen densitometry and autoradiographic grain counting with the Quantimet 720D image-analysis system. III. Improvements in Feulgen densitometry.

    PubMed

    Sklarew, R J

    1983-10-01

    A method has been developed for densitometric estimation of the Feulgen-stained DNA content of 3H-labeled nuclei in autoradiographs in conjunction with automated grain counting using a Quantimet Imaging System. Refinements in the methodology are reported which include 1) the incorporation of an Image-Editor Module into the Quantimet module configuration; 2) the optimization of incident illumination based upon evaluation of various light sources; 3) changes in the optical configuration which reduce glare and minimize the level of monitor shading correction; 4) the optimization of scanner sensitivity; and 5) the evaluation of cell-flattening and staining with respect to densitometry resolution and sensitivity. These refinements resulted in a CV of less than 6.4% in the G-1 and G-2 DNA peaks of rat kidney cells in autoradiographs compared to the previous CV of 10.5%, and a G-2 to G-1 ratio of 2.025. For a fixed field position the CV was 5.1% and the replication error less than 1.0%.

  3. Wide-field and high-resolution optical imaging for early detection of oral neoplasia

    NASA Astrophysics Data System (ADS)

    Pierce, Mark C.; Schwarz, Richard A.; Rosbach, Kelsey; Roblyer, Darren; Muldoon, Tim; Williams, Michelle D.; El-Naggar, Adel K.; Gillenwater, Ann M.; Richards-Kortum, Rebecca

    2010-02-01

    Current procedures for oral cancer screening typically involve visual inspection of the entire tissue surface at risk under white light illumination. However, pre-cancerous lesions can be difficult to distinguish from many benign conditions when viewed under these conditions. We have developed wide-field (macroscopic) imaging system which additionally images in cross-polarized white light, narrowband reflectance, and fluorescence imaging modes to reduce specular glare, enhance vascular contrast, and detect disease-related alterations in tissue autofluorescence. We have also developed a portable system to enable high-resolution (microscopic) evaluation of cellular features within the oral mucosa in situ. This system is a wide-field epi-fluorescence microscope coupled to a 1 mm diameter, flexible fiber-optic imaging bundle. Proflavine solution was used to specifically label cell nuclei, enabling the characteristic differences in N/C ratio and nuclear distribution between normal, dysplastic, and cancerous oral mucosa to be quantified. This paper discusses the technical design and performance characteristics of these complementary imaging systems. We will also present data from ongoing clinical studies aimed at evaluating diagnostic performance of these systems for detection of oral neoplasia.

  4. Framework for hyperspectral image processing and quantification for cancer detection during animal tumor surgery

    NASA Astrophysics Data System (ADS)

    Lu, Guolan; Wang, Dongsheng; Qin, Xulei; Halig, Luma; Muller, Susan; Zhang, Hongzheng; Chen, Amy; Pogue, Brian W.; Chen, Zhuo Georgia; Fei, Baowei

    2015-12-01

    Hyperspectral imaging (HSI) is an imaging modality that holds strong potential for rapid cancer detection during image-guided surgery. But the data from HSI often needs to be processed appropriately in order to extract the maximum useful information that differentiates cancer from normal tissue. We proposed a framework for hyperspectral image processing and quantification, which includes a set of steps including image preprocessing, glare removal, feature extraction, and ultimately image classification. The framework has been tested on images from mice with head and neck cancer, using spectra from 450- to 900-nm wavelength. The image analysis computed Fourier coefficients, normalized reflectance, mean, and spectral derivatives for improved accuracy. The experimental results demonstrated the feasibility of the hyperspectral image processing and quantification framework for cancer detection during animal tumor surgery, in a challenging setting where sensitivity can be low due to a modest number of features present, but potential for fast image classification can be high. This HSI approach may have potential application in tumor margin assessment during image-guided surgery, where speed of assessment may be the dominant factor.

  5. Designing Flight Deck Procedures

    NASA Technical Reports Server (NTRS)

    Degani, Asaf; Wiener, Earl

    2005-01-01

    Three reports address the design of flight-deck procedures and various aspects of human interaction with cockpit systems that have direct impact on flight safety. One report, On the Typography of Flight- Deck Documentation, discusses basic research about typography and the kind of information needed by designers of flight deck documentation. Flight crews reading poorly designed documentation may easily overlook a crucial item on the checklist. The report surveys and summarizes the available literature regarding the design and typographical aspects of printed material. It focuses on typographical factors such as proper typefaces, character height, use of lower- and upper-case characters, line length, and spacing. Graphical aspects such as layout, color coding, fonts, and character contrast are discussed; and several cockpit conditions such as lighting levels and glare are addressed, as well as usage factors such as angular alignment, paper quality, and colors. Most of the insights and recommendations discussed in this report are transferable to paperless cockpit systems of the future and computer-based procedure displays (e.g., "electronic flight bag") in aerospace systems and similar systems that are used in other industries such as medical, nuclear systems, maritime operations, and military systems.

  6. Light-scattering properties of a Venetian blind slat used for daylighting applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nilsson, Annica M.; Jonsson, Jacob C.

    2010-12-15

    The low cost, simplicity, and aesthetic appearance of external and internal shading devices, make them commonly used for daylighting and glare-control applications. Shading devices, such as Venetian blinds, screens, and roller shades, generally exhibit light scattering and/or light redirecting properties. This requires the bi-directional scattering distribution function (BSDF) of the material to be known in order to accurately predict the daylight distribution and energy flow through the fenestration system. Acquiring the complete BSDF is not a straightforward task, and to complete the process it is often required that a model is used to complement the measured data. In this project,more » a Venetian blind slat with a white top surface and a brushed aluminum bottom surface was optically characterized. A goniophotometer and an integrating sphere spectrophotometer were used to determine the angle resolved and hemispherical reflectance of the sample, respectively. The acquired data were fitted to a scattering model providing one Lambertian and one angle dependent description of the surface properties. These were used in combination with raytracing to obtain the complete BSDFs of the Venetian blind system. (author)« less

  7. "Let There Be Night" Advocates Dark Skies

    NASA Astrophysics Data System (ADS)

    Bueter, Chuck

    2008-05-01

    Let There Be Night is an interactive planetarium program that supports a community-wide experiment to quantify local sky glow. In the planetarium, visitors will experience three aspects of light pollution--glare, sky glow, and light trespass--and decide whether and how to confront dark sky issues. Planetarians can select optional recorded stories and lessons to complement live demonstrations or star talks. As a companion experiment, students in grades 3-8 from one school district will then submit their backyard observations of Orion's limiting magnitude to the 2009 Globe at Night star hunt while small student teams concurrently quantify sky glow from each schoolyard with hand-held meters. After mapping their results and having classroom discussions, students will present their findings to the School Board. Material compiled and created for the program will be available for other dark sky advocates at www.LetThereBeNight.com, while large digital files will be distributed on disk through two planetarium associations. A 2008 Toyota TAPESTRY grant has enticed significant professional support, additional funding, and in-kind contributions.

  8. Impacts of Fog Characteristics, Forward Illumination, and Warning Beacon Intensity Distribution on Roadway Hazard Visibility

    PubMed Central

    2016-01-01

    Warning beacons are critical for the safety of transportation, construction, and utility workers. These devices need to produce sufficient luminous intensity to be visible without creating glare to drivers. Published standards for the photometric performance of warning beacons do not address their performance in conditions of reduced visibility such as fog. Under such conditions light emitted in directions other than toward approaching drivers can create scattered light that makes workers and other hazards less visible. Simulations of visibility of hazards under varying conditions of fog density, forward vehicle lighting, warning beacon luminous intensity, and intensity distribution were performed to assess their impacts on visual performance by drivers. Each of these factors can influence the ability of drivers to detect and identify workers and hazards along the roadway in work zones. Based on the results, it would be reasonable to specify maximum limits on the luminous intensity of warning beacons in directions that are unlikely to be seen by drivers along the roadway, limits which are not included in published performance specifications. PMID:27314058

  9. [Implantation of an Artificial Iris in 11 Patients].

    PubMed

    Kniestedt, C; Eberhard, R; Fleischhauer, J

    2016-04-01

    Background. Iris defects are mostly acquired after injury, or may be iatrogenic after surgical excision of iris tumours or the result of collateral trauma after anterior segment surgery. They cause severe visual disability, e.g. glare, loss of contrast sensitivity, and loss of best corrected visual acuity. The foldable Koch iris prosthesis has a customised iris design and may be used to reconstruct the anterior segment in patients with partial or complete aniridia. History and Signs. We present the surgical management and clinical course of 6 patients with traumatic iris defects, together with 3 patients with partial aniridia after cataract surgery. Cataract surgery and implantation of an artificial iris were performed in 2 female patients (3 eyes) with congenital aniridia syndrome. Therapy and Outcome. No patient exhibited complications in the postoperative course, with the exception of various intraocular pressure peaks due to secondary glaucoma, that were all corrected by medication to lower topical pressure. Conclusions. In patients with major iris defects, the artificial iris allows functionally and aesthetically satisfactory reconstruction of the anterior segment. Georg Thieme Verlag KG Stuttgart · New York.

  10. Application of large-area chromogenics to architectural glazings

    NASA Astrophysics Data System (ADS)

    Selkowitz, Stephen E.

    1990-03-01

    Glass plays a significant role in the design of building envelopes today. Since its emergence during the last century as a major building material, glass has evolved into an ubiquitous and versatile building design element, performing functions today that would have been unimaginable a few years ago. The optical clarity and transparency of glass that we take for granted is one of its most unique features. Glass windows keep out the cold wind and rain without blocking the view, but also perform many more complex functions which require variable properties and tradeoffs between conflicting conditions. The glazing that provides view must also provide visual privacy at other times and must sometimes become totally opaque (for audiovisual shows, for example). Transparent glass admits daylight, providing good color rendition and offsetting electric lighting energy needs, but it can also create discomfort and disability glare conditions. The sun provides desirable warmth in winter but its heat is unwelcome in summer when it contributes to thermal discomfort and cooling energy requirements. And glass is an important element in the appearance and aesthetics of a building, both interior and exterior.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinson, A. B. F.; DeVries, M. J.; Libera, J. A.

    Growing interest in Fe{sub 2}O{sub 3} as a light harvesting layer in solar energy conversion devices stems from its unique combination of stability, nontoxicity, and exceptionally low material cost. Unfortunately, the known methods for conformally coating high aspect ratio structures with Fe{sub 2}O{sub 3} leave a glaring gap in the technologically relevant temperature range of 170-350 C. Here, we elucidate a self-limiting atomic layer deposition (ALD) process for the growth of hematite, {alpha}-Fe{sub 2}O{sub 3}, over a moderate temperature window using ferrocene and ozone. At 200 C, the self-limiting growth of Fe{sub 2}O{sub 3} is observed at rates up tomore » 1.4 {angstrom}/cycle. Dense and robust thin films grown on both fused quartz and silicon exhibit the expected optical bandgap (2.1 eV). In situ mass spectrometric analysis reveals the evolution of two distinct cyclic reaction products during the layer-by-layer growth. The readily available and relatively high vapor pressure iron precursor is utilized to uniformly coat a high surface area template with aspect ratio 150.« less

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinson, Alex B.F.; DeVries, Michael J.; Libera, J. A.

    Growing interest in Fe 2O 3 as a light harvesting layer in solar energy conversion devices stems from its unique combination of stability, nontoxicity, and exceptionally low material cost. Unfortunately, the known methods for conformally coating high aspect ratio structures with Fe 2O 3 leave a glaring gap in the technologically relevant temperature range of 170-350 °C. Here, we elucidate a self-limiting atomic layer deposition (ALD) process for the growth of hematite, α-Fe 2O 3, over a moderate temperature window using ferrocene and ozone. At 200 °C, the self-limiting growth of Fe 2O 3 is observed at rates up tomore » 1.4 Å/cycle. Dense and robust thin films grown on both fused quartz and silicon exhibit the expected optical bandgap (2.1 eV). In situ mass spectrometric analysis reveals the evolution of two distinct cyclic reaction products during the layer-by-layer growth. The readily available and relatively high vapor pressure iron precursor is utilized to uniformly coat a high surface area template with aspect ratio ~150.« less

  13. Benchmarking the performance of fixed-image receptor digital radiographic systems part 1: a novel method for image quality analysis.

    PubMed

    Lee, Kam L; Ireland, Timothy A; Bernardo, Michael

    2016-06-01

    This is the first part of a two-part study in benchmarking the performance of fixed digital radiographic general X-ray systems. This paper concentrates on reporting findings related to quantitative analysis techniques used to establish comparative image quality metrics. A systematic technical comparison of the evaluated systems is presented in part two of this study. A novel quantitative image quality analysis method is presented with technical considerations addressed for peer review. The novel method was applied to seven general radiographic systems with four different makes of radiographic image receptor (12 image receptors in total). For the System Modulation Transfer Function (sMTF), the use of grid was found to reduce veiling glare and decrease roll-off. The major contributor in sMTF degradation was found to be focal spot blurring. For the System Normalised Noise Power Spectrum (sNNPS), it was found that all systems examined had similar sNNPS responses. A mathematical model is presented to explain how the use of stationary grid may cause a difference between horizontal and vertical sNNPS responses.

  14. Optical characterization of display screens by speckle-contrast measurements

    NASA Astrophysics Data System (ADS)

    Pozo, Antonio M.; Castro, José J.; Rubiño, Manuel

    2012-10-01

    In recent years, the flat-panel display (FPD) technology has undergone great development. Currently, FPDs are present in many devices. A significant element in FPD manufacturing is the display front surface. Manufacturers sell FPDs with different types of front surface which can be matte (also called anti-glare) or glossy screens. Users who prefer glossy screens consider images shown in these types of displays to have more vivid colours compared with matte-screen displays. However, external light sources may cause unpleasant reflections on the glossy screens. These reflections can be reduced by a matte treatment in the front surface of FPDs. In this work, we present a method to characterize the front surface of FPDs using laser speckle patterns. We characterized three FPDs: a Samsung XL2370 LCD monitor of 23" with matte screen, a Toshiba Satellite A100 laptop of 15.4" with glossy screen, and a Papyre electronic book reader. The results show great differences in speckle contrast values for the three screens characterized and, therefore, this work shows the feasibility of this method for characterizing and comparing FPDs which have different types of front surfaces.

  15. Hindrances to Green Building Developments in Nigeria’s Built Environment: “The Project Professionals’ Perspectives”

    NASA Astrophysics Data System (ADS)

    Dalibi, S. G.; Feng, J. C.; Shuangqin, Liu; Sadiq, Abubakar; Bello, B. S.; Danja, I. I.

    2017-05-01

    Developing countries like Nigeria are faced with the growth of residential housing sector accompanied by huge power, water, and material consumptions etc., which were due to the population growth, increased households and the increased urbanization. The construction industry is guilty of many practices because its activities have adversely affected the environment negatively. It responded with new initiative called Eco / green / sustainable buildings to ensure environmental sustainability. Despite all these glaring challenges green building developments and sustainable practices are embraced very slowly and practiced at slow pace in the Nigeria’s construction industry. This is worrisome and is due to some factors hindering such pace. The aim of this paper is to identify, examine and assess the factors that are hindering green building developments based on the project professionals’ perceptions. Reviewed literatures were used to identify the various factors that hindered the adoption of green measures and practices within the Nigeria’s built environment. A questionnaire survey was conducted within the industry. The results showed the major factors hindering green building developments and practices in the Nigeria’s built environment.

  16. [Meta-analysis of clinical randomized controlled trials comparing refractive with diffractive multifocal intraocular lenses in cataract surgery].

    PubMed

    Shao, Dewang; He, Shouzhi

    2014-02-01

    To systematic review the effectiveness of refractive multifocal intraocular lens (MIOL) versus diffractive MIOL in the treatment of cataract. Randomized controlled trials comparing refractive MIOL with diffractive MIOL were identified by searching PubMed (1966 to May, 2013), EMbase (1980 to May, 2013), Medline (1966 to May, 2013), and The Cochrane Library (Issue 1, 2013). We also hand-searched related journals. All the searches were restricted in English or Chinese. Methodological quality of randomized controlled trials (RCT) was evaluated by simple evaluate method that recommended by the Cochrane Collaboration. Data extracted by two reviewers with designed extraction form. RevMan software (release 5.2) was used for data management and analysis. A total of 11 trials (1460 eyes) were included for systematic review. Subgroup analyses were used according to different model comparison of MIOL. The results showed a significant difference in the mean of the uncorrected distance visual acuity (UCDVA) and the uncorrected intermediate visual acuity (UCIVA) in the refractive MIOL group with WMD -0.04, 95%CI -0.06 to -0.03 (P < 0.01) and WMD -0.05, 95%CI -0.09 to -0.02 (P = 0.001). It showed a significantly difference in the mean of the uncorrected near visual acuity (UCNVA), complete spectacle independent rate, halo rate and glare rate in the diffractive MIOL group with WMD 0.11, 95%CI 0.08 to 0.15 (P < 0.01), WMD 2.98, 95%CI 2.17 to 4.09 (P < 0.01), WMD 1.52, 95%CI 1.14 to 2.04 (P = 0.004) and WMD 1.27, 95%CI 1.07 to 1.50 (P = 0.005). There was no significant difference between the two groups in the mean of the best corrected distance visual acuity (BCDVA), the best distance corrected intermediate visual acuity (BDCIVA), the best distance corrected near visual acuity (BDCNVA) and the best corrected near visual acuity (BCNVA) with WMD -0.01, 95%CI -0.03 to 0.01 (P = 0.45), WMD -0.06, 95%CI -0.15 to 0.03 (P = 0.18), WMD 0.08, 95%CI -0.01 to 0.17 (P = 0.09) and WMD -0.02, 95%CI -0.26 to 0.23 (P = 0.88). Patients implanted with refractive MIOL show better uncorrected distance and intermediate visual acuity; patients implanted with diffractive MIOL show better uncorrected near visual acuity with less likely to appear light halo, glare and other visual adverse reactions. As for spectacles correction cases, patients implanted with diffractive or refractive MIOL have considerable performances in the far, middle, near visual acuity.

  17. An integrated strategy for improving contrast, durability, and portability of a Pocket Colposcope for cervical cancer screening and diagnosis

    PubMed Central

    Mueller, Jenna; Asma, Betsy; Asiedu, Mercy; Krieger, Marlee S.; Chitalia, Rhea; Dahl, Denali; Taylor, Peyton; Schmitt, John W.; Ramanujam, Nimmi

    2018-01-01

    Introduction We have previously developed a portable Pocket Colposcope for cervical cancer screening in resource-limited settings. In this manuscript we report two different strategies (cross-polarization and an integrated reflector) to improve image contrast levels achieved with the Pocket Colposcope and evaluate the merits of each strategy compared to a standard-of-care digital colposcope. The desired outcomes included reduced specular reflection (glare), increased illumination beam pattern uniformity, and reduced electrical power budget. In addition, anti-fogging and waterproofing features were incorporated to prevent the Pocket Colposcope from fogging in the vaginal canal and to enable rapid disinfection by submersion in chemical agents. Methods Cross-polarization (Generation 3 Pocket Colposcope) and a new reflector design (Generation 4 Pocket Colposcope) were used to reduce glare and improve contrast. The reflector design (including the angle and height of the reflector sidewalls) was optimized through ray-tracing simulations. Both systems were characterized with a series of bench tests to assess specular reflection, beam pattern uniformity, and image contrast. A pilot clinical study was conducted to compare the Generation 3 and 4 Pocket Colposcopes to a standard-of-care colposcope (Leisegang Optik 2). Specifically, paired images of cervices were collected from the standard-of-care colposcope and either the Generation 3 (n = 24 patients) or the Generation 4 (n = 32 patients) Pocket Colposcopes. The paired images were blinded by device, randomized, and sent to an expert physician who provided a diagnosis for each image. Corresponding pathology was obtained for all image pairs. The primary outcome measures were the level of agreement (%) and κ (kappa) statistic between the standard-of-care colposcope and each Pocket Colposcope (Generation 3 and Generation 4). Results Both generations of Pocket Colposcope had significantly higher image contrast when compared to the standard-of-care colposcope. The addition of anti-fog and waterproofing features to the Generation 3 and 4 Pocket Colposcope did not impact image quality based on qualitative and quantitative metrics. The level of agreement between the Generation 3 Pocket Colposcope and the standard-of-care colposcope was 75.0% (kappa = 0.4000, p = 0.0028, n = 24). This closely matched the level of agreement between the Generation 4 Pocket Colposcope and the standard-of-care colposcope which was also 75.0% (kappa = 0.4941, p = 0.0024, n = 32). Conclusion Our results indicate that the Generation 3 and 4 Pocket Colposcopes perform comparably to the standard-of-care colposcope, with the added benefit of being low-cost and waterproof, which is ideal for use in resource-limited settings. Additionally, the reflector significantly reduces the electrical requirements of the Generation 4 Pocket Colposcope enhancing portability without altering performance compared to the Generation 3 system. PMID:29425225

  18. Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery.

    PubMed

    Ong, Hon Shing; Evans, Jennifer R; Allan, Bruce D S

    2014-05-01

    Following cataract surgery and intraocular lens (IOL) implantation, loss of accommodation or postoperative presbyopia occurs and remains a challenge. Standard monofocal IOLs correct only distance vision; patients require spectacles for near vision. Accommodative IOLs have been designed to overcome loss of accommodation after cataract surgery. To define (a) the extent to which accommodative IOLs improve unaided near visual function, in comparison with monofocal IOLs; (b) the extent of compromise to unaided distance visual acuity; c) whether a higher rate of additional complications is associated the use of accommodative IOLs. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 9), Ovid MEDLINE, Ovid MEDLINE in-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily Update, Ovid OLDMEDLINE (January 1946 to October 2013), EMBASE (January 1980 to October 2013), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to October 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrial.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 10 October 2013. We include randomised controlled trials (RCTs) which compared implantation of accommodative IOLs to implantation of monofocal IOLs in cataract surgery. Two authors independently screened search results, assessed risk of bias and extracted data. All included trials used the 1CU accommodative IOL (HumanOptics, Erlangen, Germany) for their intervention group. One trial had an additional arm with the AT-45 Crystalens accommodative IOL (Eyeonics Vision). We performed a separate analysis comparing 1CU and AT-45 IOL. We included four RCTs, including 229 participants (256 eyes), conducted in Germany, Italy and the UK. The age range of participants was 21 to 87 years. All studies included people who had bilateral cataracts with no pre-existing ocular pathologies. We judged all studies to be at high risk of performance bias. We graded two studies with high risk of detection bias and one study with high risk of selection bias.Participants who received the accommodative IOLs achieved better distance-corrected near visual acuity (DCNVA) at six months (mean difference (MD) -3.10 Jaeger units; 95% confidence intervals (CI) -3.36 to -2.83, 2 studies, 106 people, 136 eyes, moderate quality evidence). Better DCNVA was seen in the accommodative lens group at 12 to 18 months in the three trials that reported this time point but considerable heterogeneity of effect was seen, ranging from 1.3 (95% CI 0.98 to 1.68; 20 people, 40 eyes) to 6 (95% CI 4.15 to 7.85; 51 people, 51 eyes) Jaeger units and 0.12 (95% CI 0.05 to 0.19; 40 people, binocular) logMAR improvement (low quality evidence). The relative effect of the lenses on corrected distant visual acuity (CDVA) was less certain. At six months there was a standardised mean difference of -0.04 standard deviations (95% CI -0.37 to 0.30, 2 studies, 106 people, 136 eyes, low quality evidence). At long-term follow-up there was heterogeneity of effect with 18-month data in two studies showing that CDVA was better in the monofocal group (MD 0.12 logMAR; 95% CI 0.07 to 0.16, 2 studies, 70 people,100 eyes) and one study which reported data at 12 months finding similar CDVA in the two groups (-0.02 logMAR units, 95% CI -0.06 to 0.02, 51 people) (low quality evidence).The relative effect of the lenses on reading speed and spectacle independence was uncertain, The average reading speed was 11.6 words per minute more in the accommodative lens group but the 95% confidence intervals ranged from 12.2 words less to 35.4 words more (1 study, 40 people, low quality evidence). People with accommodative lenses were more likely to be spectacle-independent but the estimate was very uncertain (risk ratio (RR) 8.18; 95% CI 0.47 to 142.62, 1 study, 40 people, very low quality evidence).More cases of posterior capsule opacification (PCO) were seen in accommodative lenses but the effect of the lenses on PCO was uncertain (Peto odds ratio (OR) 2.12; 95% CI 0.45 to 10.02, 91 people, 2 studies, low quality evidence). People in the accommodative lens group were more likely to require laser capsulotomy (Peto OR 7.96; 95% CI 2.49 to 25.45, 2 studies, 60 people, 80 eyes, low quality evidence). Glare was reported less frequently with accommodative lenses but the relative effect of the lenses on glare was uncertain (RR any glare 0.78; 95% CI 0.32 to 1.90, 1 study, 40 people, and RR moderate/severe glare 0.45; 95% CI 0.04 to 4.60, low quality evidence). There is moderate-quality evidence that study participants who received accommodative IOLs had a small gain in near visual acuity after six months. There is some evidence that distance visual acuity with accommodative lenses may be worse after 12 months but due to low quality of evidence and heterogeneity of effect, the evidence for this is not clear-cut. People receiving accommodative lenses had more PCO which may be associated with poorer distance vision. However, the effect of the lenses on PCO was uncertain.Further research is required to improve the understanding of how accommodative IOLs may affect near visual function, and whether they provide any durable gains. Additional trials, with longer follow-up, comparing different accommodative IOLs, multifocal IOLs and monofocal IOLs, would help map out their relative efficacy, and associated late complications. Research is needed on control over capsular fibrosis postimplantation.Risks of bias, heterogeneity of outcome measures and study designs used, and the dominance of one design of accommodative lens in existing trials (the HumanOptics 1CU) mean that these results should be interpreted with caution. They may not be applicable to other accommodative IOL designs.

  19. Environmental and economic assessment of a road safety product made with virgin and recycled HDPE: a comparative study.

    PubMed

    L Simões, Carla; Costa Pinto, Lígia M; Bernardo, C A

    2013-01-15

    The development of value-added products made from post-consumer plastic recyclates has become an important goal in the quest for a sustainable society. To attain such goal, tools with higher accuracy and wider scope are increasingly necessary. The present work describes the application of a Life Cycle Assessment (LCA)/Life Cycle Costing (LCC) integrated model, with inclusion of externalities (environmental and social costs), to Anti-Glare Lamellae (AGL) made with High Density Polyethylene (HDPE). It compares an AGL currently manufactured from virgin HDPE (current AGL) with an alternative one made with recycled HDPE (optional AGL). The results obtained show that neither the current nor the optional AGL depict the best environmental performance in all impact categories. Nevertheless, there is a clear overall environmental and economic advantage in replacing virgin HDPE with recycled HDPE. The present work also makes evident that the LCA/LCC integrated model allows the identification of economic and environmental win-win and trade-off situations related to the full life cycle of products. As such, its results can be used as valuable guidelines in product development. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. [A rare case of Graves' disease in a patient on regular haemodialysis].

    PubMed

    Boubaker, Karima; Ounissi, Mondher; Khiari, Karima; Harzallah, Amel; Abbes, Monia; El Younsi, Fethi; Ben Abdellah, Taieb; Ben Maïz, Hedi; Kaaroud, Hayet; Kheder, Adel

    2010-07-01

    Abnormal thyroid hormone production and metabolism are relatively common in chronic renal failure and in regular haemodialysis. Graves' disease is a very unusual condition and is difficult to identify. We report a case of Graves' disease in a patient on regular hemodialysis. A 26-year-old man undergoing regular hemodialysis from unknown chronic nephropathy since four years. The patient suffered from unexplained slimming and aggressiveness. On admission, he had an irritability, tremor of the extremities, arterial hypertension not controlled by the medical treatment, discrete asynergy oculo-palpebral, glare of the glance and protrusion of the ocular spheres. The thyroid was non palpable. Biological tests demonstrated hyperthyroidism. Thyroid-stimulating hormone receptor antibodies were positive. Thyroid echography and scintiscanning showed vascular and hyperfonctionnel character of the thyroid. The patient was treated radically by radioactive iodine 131 therapy after medical preparation by antithyroid agent. He developed hypothyroidism treated by substitutive treatment. The diagnosis of Graves' disease must be evoked even in the absence of specific symptoms in haemodialysis patients. In front of clinical symptoms, since the conventional treatment is effective and inoffensive. Copyright 2010 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  1. Enhancing colposcopy with polarized light.

    PubMed

    Ferris, Daron G; Li, Wenjing; Gustafsson, Ulf; Lieberman, Richard W; Galdos, Oscar; Santos, Carlos

    2010-07-01

    To determine the potential utility of polarized light used during colposcopic examinations. Matched, polarized, and unpolarized colposcopic images and diagnostic annotations from 31 subjects receiving excisional treatment of cervical neoplasia were compared. Sensitivity, specificity, and mean Euclidean distances between the centroids of the gaussian ellipsoids for the different epithelial types were calculated for unpolarized and polarized images. The sensitivities of polarized colposcopic annotations for discriminating cervical intraepithelial neoplasia (CIN) 2 or higher were greater for all 3 acetowhite categories when compared with unpolarized annotations (58% [44/76] vs 45% [34/76], 68% [50/74] vs 59% [45/76], and 68% [49/72] vs 66% [50/76], respectively). The average percent differences in Euclidean distances between the epithelial types for unpolarized and polarized cervical images were as follows: CIN 2/3 versus CIN 1 = 33% (10/30, p =.03), CIN 2/3 versus columnar epithelium = 22% (p =.004), CIN 2/3 versus immature metaplasia = 29% (14/47, p =.11), and CIN 1 versus immature metaplasia = 27% (4.4/16, p =.16). Because of its ability to interrogate at a deeper plane and eliminate obscuring glare, polarized light colposcopy may enhance the evaluation and detection of cervical neoplasias.

  2. A visit to Stromboli, lighthouse of the Mediterranean

    USGS Publications Warehouse

    Bullard, F. M.

    1987-01-01

    About daybreak of the next morning, the perfect cone-shaped outline of Stromboli appeared on the horizon. No "red" glare could be seen, but a prominent column of white vapor was rising from the crater, and at infrequent emitted. As the boat steamed around the edge of Stromboli, the big "scar' on the slope, known as Sciara del Fuoco, stood out prominently. This remarkable feature, with a slope of 35 degrees and a width of about three-quarters of a mile, is like a tremendous talus slope and extends from the crater to the sea, a distance of about 4,000 feet. Much of the erupted material, including lava flows ejected from the crater, lands on the Sciara del Fuoco and rolls directly into the sea. The origin of the Sciara del Fuoco is uncertain, but it appears to represent a great depression formed by an eruption which destroyed one side of the cone. The accumulation of debris in the depression has built up the present talus-like slope. The crater of Stromboli is on a terrace at the top of the Sciara del Fuoco, about 600 feet below the summit peak.                         

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draper, Zachary H.; Duchêne, Gaspard; Millar-Blanchaer, Maxwell A.

    Using the Gemini Planet Imager, we have resolved the circumstellar debris disk around HD 111520 at a projected range of ~30–100 AU in both total and polarized H-band intensity. The disk is seen edge-on at a position angle of 165° along the spine of emission. A slight inclination and asymmetric warp are covariant and alter the interpretation of the observed disk emission. We employ three point-spread function subtraction methods to reduce the stellar glare and instrumental artifacts to confirm that there is a roughly 2:1 brightness asymmetry between the NW and SE extension. This specific feature makes HD 111520 themore » most extreme example of asymmetric debris disks observed in scattered light among similar highly inclined systems, such as HD 15115 and HD 106906. We further identify a tentative localized brightness enhancement and scale height enhancement associated with the disk at ~40 AU away from the star on the SE extension. We also find that the fractional polarization rises from 10% to 40% from 0".5 to 0".8 from the star. Lastly, the combination of large brightness asymmetry and symmetric polarization fraction leads us to believe that an azimuthal dust density variation is causing the observed asymmetry.« less

  4. The importance of stochasticity and internal variability in geomorphic erosion system

    NASA Astrophysics Data System (ADS)

    Kim, J.; Ivanov, V. Y.; Fatichi, S.

    2016-12-01

    Understanding soil erosion is essential for a range of studies but the predictive skill of prognostic models and reliability of national-scale assessments have been repeatedly questioned. Indeed, data from multiple environments indicate that fluvial soil loss is highly non-unique and its frequency distributions exhibit heavy tails. We reveal that these features are attributed to the high sensitivity of erosion response to micro-scale variations of soil erodibility - `geomorphic internal variability'. The latter acts as an intermediary between forcing and erosion dynamics, augmenting the conventionally emphasized effects of `external variability' (climate, topography, land use, management form). Furthermore, we observe a reduction of erosion non-uniqueness at larger temporal scales that correlates with environment stochasticity. Our analysis shows that this effect can be attributed to the larger likelihood of alternating characteristic regimes of sediment dynamics. The corollary of this study is that the glaring gap - the inherently large uncertainties and the fallacy of representativeness of central tendencies - must be conceded in soil loss assessments. Acknowledgement: This research was supported by a grant (16AWMP-B083066-03) from Water Management Research Program funded by Ministry of Land, Infrastructure and Transport of Korean government, and by the faculty research fund of Sejong University in 2016.

  5. The politics of assessment: water and sanitation MDGs in the Middle East.

    PubMed

    Zawahri, Neda; Sowers, Jeannie; Weinthal, Erika

    2011-01-01

    The Middle East and North Africa (MENA) is generally considered to be making adequate progress towards meeting Target 10 of the Millennium Development Goals (MDGs), which calls for halving the proportion of the population with inadequate access to drinking water and sanitation. Progress towards achieving Target 10 is evaluated by the Joint Monitoring Programme (JMP), run by UNICEF and WHO. This article shows that the assessment methodologies employed by the JMP significantly overstate coverage rates in the drinking water and sanitation sectors, by overlooking and ‘not counting’ problems of access, affordability, quality of service and pollution. The authors show that states in MENA often fail to provide safe drinking water and adequate sanitation services, particularly in densely populated informal settlements, and that many centralized water and sanitation infrastructures contribute to water pollution and contamination. Despite the glaring gap between the MDG statistics and the evidence available from national and local reports, exclusionary political regimes in the region have had few incentives to adopt more accurate assessments and improve the quality of service. While international organizations have proposed some reforms, they too lack incentives to employ adequate measures that gauge access, quality and affordability of drinking water and sanitation services.

  6. Medical malpractice, defensive medicine and role of the "media" in Italy.

    PubMed

    Toraldo, Domenico M; Vergari, Ughetta; Toraldo, Marta

    2015-01-01

    For many years until now, Italy has been subjected to an inconsistent and contradictory media campaign. On one hand the "media" present us with bold and reassuring messages about the progress of medical science; on the other hand they are prone to kneejerk criticism every time medical treatment does not have the desired effect, routinely describing such cases as glaring examples of "malasanità", an Italian word of recent coinage used to denote medical malpractice. Newspaper reports of legal proceedings involving health treatment are frequently full of errors and lack any scientific basis. The published data confirm the unsustainably high number of lawsuits against doctors and medical structures, accompanied by demands for compensation arising from true or alleged medical errors or mistakes blamed on the work of health structures. Currently Italian citizens have a greater awareness of their right to health than in the past, and patients' expectations have risen. A discrepancy is emerging between the current state of medical science and the capacities of individual doctors and health structures. Lastly, there is a need for greater monitoring of the quality of health care services and a greater emphasis on health risk prevention.

  7. Influence of the impact assessment method on the conclusions of a LCA study. Application to the case of a part made with virgin and recycled HDPE.

    PubMed

    Simões, Carla L; Xará, Susana M; Bernardo, C A

    2011-10-01

    Recent legislation has stressed the need to decide the best end-of-life (EoL) option for post-consumer products considering their full life-cycle and the corresponding overall environmental impacts. The life cycle assessment (LCA) technique has become a common tool to evaluate those impacts. The present study aimed to contribute to the better understanding of the application of this technique, by evaluating the influence of the selection of the life cycle impact assessment (LCIA) method in its results and conclusions. A specific case study was chosen, using previous information related to an anti-glare lamellae (AGL) for highway use, made with virgin and recycled high-density polyethylene (HDPE). Five distinct LCIA methods were used: Eco-indicator 99, CML 2 (2000), EPS 2000, Eco-indicator 95 and EDIP 97. Consistent results between these methods were obtained for the Climate change, Ozone layer depletion, Acidification and Eutrophication environmental indicators. Conversely, the Summer smog indicator showed large discrepancies between impact assessment methods. The work sheds light on the advantages inherent in using various LCIA methods when doing the LCA study of a specific product, thus evidencing complementary analysis perspectives.

  8. Microscopy illumination engineering using a low-cost liquid crystal display.

    PubMed

    Guo, Kaikai; Bian, Zichao; Dong, Siyuan; Nanda, Pariksheet; Wang, Ying Min; Zheng, Guoan

    2015-02-01

    Illumination engineering is critical for obtaining high-resolution, high-quality images in microscope settings. In a typical microscope, the condenser lens provides sample illumination that is uniform and free from glare. The associated condenser diaphragm can be manually adjusted to obtain the optimal illumination numerical aperture. In this paper, we report a programmable condenser lens for active illumination control. In our prototype setup, we used a $15 liquid crystal display as a transparent spatial light modulator and placed it at the back focal plane of the condenser lens. By setting different binary patterns on the display, we can actively control the illumination and the spatial coherence of the microscope platform. We demonstrated the use of such a simple scheme for multimodal imaging, including bright-field microscopy, darkfield microscopy, phase-contrast microscopy, polarization microscopy, 3D tomographic imaging, and super-resolution Fourier ptychographic imaging. The reported illumination engineering scheme is cost-effective and compatible with most existing platforms. It enables a turnkey solution with high flexibility for researchers in various communities. From the engineering point-of-view, the reported illumination scheme may also provide new insights for the development of multimodal microscopy and Fourier ptychographic imaging.

  9. Assessment of a head-mounted miniature monitor

    NASA Technical Reports Server (NTRS)

    Hale, J. P., II

    1992-01-01

    Two experiments were conducted to assess the capabilities and limitations of the Private Eye, a miniature, head-mounted monitor. The first experiment compared the Private Eye with a cathode ray tube (CRT) and hard copy in both a constrained and unconstrained work envelope. The task was a simulated maintenance and assembly task that required frequent reference to the displayed information. A main effect of presentation media indicated faster placement times using the CRT as compared with hard copy. There were no significant differences between the Private Eye and either the CRT or hard copy for identification, placement, or total task times. The goal of the second experiment was to determine the effects of various local visual parameters on the ability of the user to accurately perceive the information of the Private Eye. The task was an interactive video game. No significant performance differences were found under either bright or dark ambient illumination environments nor with either visually simple or complex task backgrounds. Glare reflected off of the bezel surrounding the monitor did degrade performance. It was concluded that this head-mounted, miniature monitor could serve a useful role for in situ operations, especially in microgravity environments.

  10. Stray light characteristics of the diffractive telescope system

    NASA Astrophysics Data System (ADS)

    Liu, Dun; Wang, Lihua; Yang, Wei; Wu, Shibin; Fan, Bin; Wu, Fan

    2018-02-01

    Diffractive telescope technology is an innovation solution in construction of large light-weight space telescope. However, the nondesign orders of diffractive optical elements (DOEs) may affect the imaging performance as stray light. To study the stray light characteristics of a diffractive telescope, a prototype was developed and its stray light analysis model was established. The stray light characteristics including ghost, point source transmittance, and veiling glare index (VGI) were analyzed. During the star imaging test of the prototype, the ghost images appeared around the star image as the exposure time of the charge-coupled device improving, consistent with the simulation results. The test result of VGI was 67.11%, slightly higher than the calculated value 57.88%. The study shows that the same order diffraction of the diffractive primary lens and correcting DOE is the main factor that causes ghost images. The stray light sources outside the field of view can illuminate the image plane through nondesign orders diffraction of the primary lens and contributes to more than 90% of the stray light flux on the image plane. In summary, it is expected that these works will provide some guidance for optimizing the imaging performance of diffractive telescopes.

  11. Comparison of structural response and fatigue endurance of aircraft flap-like box structures subjected to acoustic loading

    NASA Astrophysics Data System (ADS)

    Xiao, Y.; White, R. G.; Aglietti, G. S.

    2005-05-01

    The results of an extensive test program to characterize the behavior of typical aircraft structures under acoustic loading and to establish their fatigue endurance are presented. The structures tested were the three flap-like box-type of structures. Each structure consisted of one flat (bottom) and one curved (top) stiffener stiffened skin panel, front, and rear spars, and ribs that divided the structures into three bays. The three structures, constructed from three different materials (aircraft standard aluminum alloy, Carbon Fibre Reinforced Plastic, and a Glass Fibre Metal Laminate, i.e., GLARE) had the same size and configuration, with only minor differences due to the use of different materials. A first set of acoustic tests with excitations of intensity ranging from 140 to 160 dB were carried out to obtain detailed data on the dynamic response of the three structures. The FE analysis of the structures is also briefly described and the results compared with the experimental data. The fatigue endurance of the structures was then determined using random acoustic excitation with an overall sound pressure level of 161 dB, and details of crack propagation are reported. .

  12. User centered design of the digital book: why looking backward can help us move forward

    NASA Astrophysics Data System (ADS)

    Wallis, Jillian C.

    2006-02-01

    What is emerging from the digital book revolution is a state of technology that has brought new affordances to the book, such as search, hyperlinking, personalization, dynamic content, 24/7 access, automated indexing and summarizing, aggregated content, and new modes of reading and access. These could solve some of the issues users have with the static content of traditional bound volumes, but the technology so far has staunchly ignored the tried and true technologies of books, such as infinite resolution, high contrast, low glare, haptic navigation, typographic niceties, and the rights of first sale to borrow, lend, or resell a work. By exploring a survey of literature, reviews, and user tests, I intend to address the point of how the current concept of the digital book is an inappropriate tool for the user and the task of reading, and as a result not been enthusiastically embraced by the market. The collected evidence indicates that it is impossible to forget our past in our quest for the future, and that technology can help us to unite the disparate realities of analog and digital to create a truly digital book.

  13. Impact Delamination and Fracture in Aluminum/Acrylic Sandwich Plates

    NASA Technical Reports Server (NTRS)

    Liaw, Benjamin; Zeichner, Glenn; Liu, Yanxiong; Bowles, Kenneth J. (Technical Monitor)

    2000-01-01

    Impact-induced delamination and fracture in 6061-T6 aluminum/cast acrylic sandwich plates adhered by epoxy were generated in an instrumented drop-weight impact machine. Although only a small dent was produced on the aluminum side when a hemispherical penetrator tup was dropped onto it from a couple of inches, a large ring of delamination at the interface was observed. The delamination damage was often accompanied by severe shattering in the acrylic substratum. Damage patterns in the acrylic layer include radial and ring cracks and, together with delamination at the interface, may cause peeling-off of acrylic material from the sandwich plate. Theory of stress-wave propagation can be used to explain these damage patterns. The impact tests were conducted at various temperatures. The results also show clearly that temperature effect is very important in impact damage. For pure cast acrylic nil-ductile transition (NDT) occurs between 185-195 F. Excessive impact energy was dissipated into fracture energy when tested at temperature below this range or through plastic deformation when tested at temperature above the NDT temperature. Results from this study will be used as baseline data for studying fiber-metal laminates, such as GLARE and ARALL for advanced aeronautical and astronautical applications.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draper, Zachary H.; Matthews, Brenda C.; Gerard, Benjamin

    Using the Gemini Planet Imager, we have resolved the circumstellar debris disk around HD 111520 at a projected range of ∼30–100 AU in both total and polarized H -band intensity. The disk is seen edge-on at a position angle of 165° along the spine of emission. A slight inclination and asymmetric warp are covariant and alter the interpretation of the observed disk emission. We employ three point-spread function subtraction methods to reduce the stellar glare and instrumental artifacts to confirm that there is a roughly 2:1 brightness asymmetry between the NW and SE extension. This specific feature makes HD 111520more » the most extreme example of asymmetric debris disks observed in scattered light among similar highly inclined systems, such as HD 15115 and HD 106906. We further identify a tentative localized brightness enhancement and scale height enhancement associated with the disk at ∼40 AU away from the star on the SE extension. We also find that the fractional polarization rises from 10% to 40% from 0.″5 to 0.″8 from the star. The combination of large brightness asymmetry and symmetric polarization fraction leads us to believe that an azimuthal dust density variation is causing the observed asymmetry.« less

  15. Commentary: Racism and Bias in Health Professions Education: How Educators, Faculty Developers, and Researchers Can Make a Difference.

    PubMed

    Karani, Reena; Varpio, Lara; May, Win; Horsley, Tanya; Chenault, John; Miller, Karen Hughes; O'Brien, Bridget

    2017-11-01

    The Research in Medical Education (RIME) Program Planning Committee is committed to advancing scholarship in and promoting dialogue about the critical issues of racism and bias in health professions education (HPE). From the call for studies focused on underrepresented learners and faculty in medicine to the invited 2016 RIME plenary address by Dr. Camara Jones, the committee strongly believes that dismantling racism is critical to the future of HPE.The evidence is glaring: Dramatic racial and ethnic health disparities persist in the United States, people of color remain deeply underrepresented in medical school and academic health systems as faculty, learner experiences across the medical education continuum are fraught with bias, and current approaches to teaching perpetuate stereotypes and insufficiently challenge structural inequities. To achieve racial justice in HPE, academic medicine must commit to leveraging positions of influence and contributing from these positions. In this Commentary, the authors consider three roles (educator, faculty developer, and researcher) represented by the community of scholars and pose potential research questions as well as suggestions for advancing educational research relevant to eliminating racism and bias in HPE.

  16. The achievements of solar children from the natural created octave whose source is the emanating sun reflected by the Foundation for Solar Achievement with the Arts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petacchi, D.V.

    The Foundation for Solar Achievement With The Arts is a not-for-profit school training gifted children in the use of their talent in accordance with the philosophy and experience that children in harmony with their natural environment based upon the sun`s position in the course of the day have the greater capacity of attention necessary to enhance learning and creativity. Uncluttered as much as possible by the distractions of technology or the artificial glare of electricity, the learning environment of the Foundation for Solar Achievement With The Arts is conducive to this hands-on action. The Foundation was started by an individualmore » whose life long search for the meaning of his life and whose pondering on the meaning human life on this planet led him to many conclusions modern science is just beginning to reach. With the help of dedicated architect John Jehring and likeminded others, Mr. Petacchi is utilizing natural sunlight in an environment conducive to the psyche of children. A building is planned that will expand into indoor form the natural lighting and free space of the out-of-doors.« less

  17. Mysterious Blob Galaxies Revealed

    NASA Image and Video Library

    2005-01-11

    This image composite shows a giant galactic blob (red) and the three merging galaxies NASA's Spitzer Space Telescope discovered within it (yellow). Blobs are intensely glowing clouds of hot hydrogen gas that envelop faraway galaxies. They are about 10 times as large as the galaxies they surround. Visible-light images reveal the vast extent of blobs, but don't provide much information about their host galaxies. Using its heat-seeking infrared eyes, Spitzer was able to see the dusty galaxies tucked inside one well-known blob located 11 billion light-years away. The findings reveal three monstrously bright galaxies, trillions of times brighter than the Sun, in the process of merging together. Spitzer also observed three other blobs located in the same cosmic neighborhood, all of which were found to be glaringly bright. One of these blobs is also known to be a galactic merger, only between two galaxies instead of three. It remains to be seen whether the final two blobs studied also contain mergers. The Spitzer data were acquired by its multiband imaging photometer. The visible-light image was taken by the Blanco Telescope at the Cerro Tololo Inter-American Observatory, Chile. http://photojournal.jpl.nasa.gov/catalog/PIA07220

  18. Developmental Benefits of Extracurricular Sports Participation Among Brazilian Youth.

    PubMed

    Reverdito, Riller S; Galatti, Larissa R; Carvalho, Humberto M; Scaglia, Alcides J; Côté, Jean; Gonçalves, Carlos E; Paes, Roberto R

    2017-10-01

    Youth sporting activities have been explored as a way to impact positive personal transformation and development, glaringly demonstrated by world-wide investments in public policies, programs, and projects. We studied positive effects of participation in sports on the developmental assets of 614 adolescents (13.1 ± 1.7 years) actively engaged in extracurricular sport programs targeted at socially disadvantaged youths, from five municipalities across five states of the southern, south-eastern and north-eastern regions of Brazil. Participants responded to a developmental assets questionnaire designed to capture sociodemographic and human development data. Multilevel logistic regression was used to explore associations between years of participation in sport and human development indicators, controlling for age and sex. Our results showed that the quality of the young people's support network and duration of program participation positively influenced sport participation, which, in turn, was associated with willingness to learn. A strong association was also observed between sport participation and developmental assets. Thus, we offer new evidence of a relationship between positive development and environmental factors in which individual and contextual forces can be aligned, and we provide new reference data for developing countries.

  19. Terrestrial Planet Finder: science overview

    NASA Technical Reports Server (NTRS)

    Unwin, Stephen C.; Beichman, C. A.

    2004-01-01

    The Terrestrial Planet Finder (TPF) seeks to revolutionize our understanding of humanity's place in the universe - by searching for Earth-like planets using reflected light, or thermal emission in the mid-infrared. Direct detection implies that TPF must separate planet light from glare of the nearby star, a technical challenge which has only in recent years been recognized as surmountable. TPF will obtain a low-resolution spectra of each planets it detects, providing some of its basic physical characteristics and its main atmospheric constituents, thereby allowing us to assess the likelihood that habitable conditions exist there. NASA has decided the scientific importance of this research is so high that TPF will be pursued as two complementary space observatories: a visible-light coronagraph and a mid-infrared formation flying interferometer. The combination of spectra from both wavebands is much more valuable than either taken separately, and it will allow a much fuller understanding of the wide diversity of planetary atmospheres that may be expected to exist. Measurements across a broad wavelength range will yield not only physical properties such as size and albedo, but will also serve as the foundations of a reliable and robust assessment of habitability and the presence of life.

  20. Optical characterization of display screens by speckle patterns

    NASA Astrophysics Data System (ADS)

    Pozo, Antonio M.; Castro, José J.; Rubiño, Manuel

    2013-10-01

    In recent years, flat-panel display (FPD) technology has undergone great development, and now FPDs appear in many devices. A significant element in FPD manufacturing is the display front surface. Manufacturers sell FPDs with different types of front surfaces, which can be matte (also called anti-glare) or glossy screens. Users who prefer glossy screens consider these displays to show more vivid colors compared with matte-screen displays. However, on the glossy screens, external light sources may cause unpleasant reflections that can be reduced by a matte treatment in the front surface. In this work, we present a method to characterize FPD screens using laser-speckle patterns. We characterize three FPDs: a Samsung XL2370 LCD monitor of 23 in. with matte screen, a Toshiba Satellite A100 LCD laptop of 15.4 in. with glossy screen, and a Grammata Papyre 6.1 electronic book reader of 6 in. with ePaper screen (E-ink technology). The results show great differences in speckle-contrast values for the three screens characterized and, therefore, this work shows the feasibility of this method for characterizing and comparing FPDs that have different types of front surfaces.

  1. DOSE EFFECT OF THE 33S(n,α) 30SI REACTION IN BNCT USING THE NEW n_TOF-CERN DATA.

    PubMed

    Sabaté-Gilarte, M; Praena, J; Porras, I; Quesada, J M

    2017-09-23

    33S is a stable isotope of sulphur which is being studied as a potential cooperative target for Boron Neutron Capture Therapy (BNCT) in accelerator-based neutron sources because of its large (n,α) cross section in the epithermal neutron energy range. Previous measurements resolved the resonances with a discrepant description of the lowest-lying and strongest one (at 13.5 keV). However, the evaluations of the major databases do not include resonances, except EAF-2010 which shows smaller values in this range than the experimental data. Furthermore, the glaring lack of data below 10 keV down to thermal (25.3 meV) has motivated a new measurement at n_TOF at CERN in order to cover the whole energy range. The inclusion of this new 33S(n,α) cross section in Monte Carlo simulations provides a more accurate estimation of the deposited kerma rate in tissue due to the presence of 33S. The results of those simulations represent the goal of this work. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. The visually impaired patient.

    PubMed

    Rosenberg, Eric A; Sperazza, Laura C

    2008-05-15

    Blindness or low vision affects more than 3 million Americans 40 years and older, and this number is projected to reach 5.5 million by 2020. In addition to treating a patient's vision loss and comorbid medical issues, physicians must be aware of the physical limitations and social issues associated with vision loss to optimize health and independent living for the visually impaired patient. In the United States, the four most prevalent etiologies of vision loss in persons 40 years and older are age-related macular degeneration, cataracts, glaucoma, and diabetic retinopathy. Exudative macular degeneration is treated with laser therapy, and progression of nonexudative macular degeneration in its advanced stages may be slowed with high-dose antioxidant and zinc regimens. The value of screening for glaucoma is uncertain; management of this condition relies on topical ocular medications. Cataract symptoms include decreased visual acuity, decreased color perception, decreased contrast sensitivity, and glare disability. Lifestyle and environmental interventions can improve function in patients with cataracts, but surgery is commonly performed if the condition worsens. Diabetic retinopathy responds to tight glucose control, and severe cases marked by macular edema are treated with laser photocoagulation. Vision-enhancing devices can help magnify objects, and nonoptical interventions include special filters and enhanced lighting.

  3. Design, construction, operation, and evaluation of solar systems for industrial process-heat applications in the intermediate-temperature range (212/sup 0/F to 550/sup 0/F). Environmental assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1982-01-01

    The environmental impacts are assessed for a proposed 50,000 square foot field of single axis tracking, concentrating solar collectors along the Ohio River in southern Ohio. The facility is planned to produce process steam for use in the production of polystyrene. Absorbed solar energy would heat an aliphatic hydrocarbon synthetic heat transfer fluid to a maximum temperature of 500/sup 0/F. The existing environment is briefly described, particularly regarding air quality. The potential environmental impacts of the solar process heat system on the air, water, soil, endangered species and archaeological and historical resources are examined, including risks due to flood andmore » glare and a comparison of alternatives. Also included are a Consent Judgment relating to two coal-fired boilers in violation of EPA regulations, property data of Gulf Synfluid 4CS (a candidate heat transfer fluid), piping and instrumentation diagrams and schematics, site grade and drainage plan, geological survey map, subsurface soil investigation, Ohio endangered species list, Ohio Archaeological Counsel certification list, and a study of heat transfer fluids and their properties. (LEW)« less

  4. Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birru, Dagnachew; Wen, Yao-Jung; Rubinstein, Francis M.

    2013-10-28

    This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach tomore » determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooley, James J.

    Shaffer’s (2010) article reports on the long term impact of less than perfect retention of anthropogenic CO2 stored in deep geologic reservoirs and in the ocean. The central thesis of this article is predicated on two deeply flawed assumptions. The first and most glaring is the implicit assumption that society has only one means of reducing greenhouse gas emissions, carbon dioxide capture and storage (CCS). Secondly, there is absolutely no geophysical nor geomechanical basis for assuming an exponential decay of CO2 stored in deep geologic formations as done by Schaffer. Shaffer’s analysis of the impact of leakage from anthropogenic CO2more » stored in deep geologic reservoirs are based upon two fundamentally flawed assumptions and therefore the reported results as well as the public policy conclusions presented in the paper need to be read with this understanding in mind as far less CO2 stored below ground because society drew upon a broad portfolio of advanced energy technologies over the coming century coupled with a more technically accurate conceptualization of CO2 storage in the deep subsurface and the important role of secondary and tertiary trapping mechanisms would have yield a far less pessimistic view of the potential role that CCS can play in a broader portfolio of societal responses to the very serious threat posed by climate change.« less

  6. The health workforce crisis: the brain drain scourge.

    PubMed

    Ike, Samuel O

    2007-01-01

    The magnitude of the health workforce crisis engendered by brain drain particularly in Africa, and nay more especially Nigeria, has been assuming increasingly alarming proportions in the past three decades. The challenge it poses in meeting the manpower needs in the healthcare sector as well as in the larger economy of the sending countries is enormous. This paper thus sets out to highlight the scope of this brain drain, its effects and the reasons sustaining it, as well as makes concrete suggestions to help stern the tide. A review of the literature on brain drain with particular emphasis on the health workforce sector was done, with focus on Africa, and specifically Nigeria. Literature search was done using mainly the Medline, as well as local journals. The historical perspectives, with the scope of external and internal brain drain are explored. The glaring effects of brain drain both in the global workforce terrain and specifically in the health sectors are portrayed. The countries affected most and the reasons for brain drain are outlined. Strategic steps to redress the brain drain crisis are proffered in this paper. The health workforce crisis resulting from brain drain must be brought to the front-burner of strategic policy decisions leading to paradigm shift in political, social and economic conditions that would serve as incentives to curb the scourge.

  7. The early phase of the SMBH-galaxy coevolution in low-z "young" galaxies

    NASA Astrophysics Data System (ADS)

    Nagao, Tohru

    2014-01-01

    It is now widely recognized that most galaxies have a supermassive black hole (SMBH) in their nucleus, and the evolution of SMBHs is closely related with that of their host galaxies (the SMBH-galaxy coevolution). This is suggested by the correlation in the mass of SMBHs and their host galaxies, that has been observed in low redshifts. However, the physics of the coevolution is totally unclear, that prevents us from complete understandings of the galaxy evolution. One possible strategy to tackle this issue is measuring the mass ratio between SMBHs and their host galaxies (M_BH/M_host) at high redshifs, since different scenarios predict different evolution of the ratio ofMBH/Mhost. However it is extremely challenging to measure the mass of the host of high-z quasars, given the faint surface brightness of the host at close to the glaring quasar nucleus. Here we propose a brand-new approach to assess the early phase of the SMBH-galaxy coevolution, by focusing on low-z AGN-hosting "young" galaxies. Specifically, we focus on some very metal-poor galaxies with broadline Balmer lines at z ~ 0.1 - 0.3. By examining the SMBH scaling relations in some low-z metal-poor AGNs through high-resolution IRCS imaging observations, we will discriminate various scenarios for the SMBH-galaxy coevolution.

  8. Look Sharp While Seeing Sharp

    NASA Technical Reports Server (NTRS)

    2006-01-01

    The two scientists James B. Stephens and Dr. Charles G. Miller were tasked with studying the harmful properties of light in space, as well as the artificial radiation produced during laser and welding work, for the purpose of creating an enhanced means of eye protection in industrial welding applications. While working to apply their space research to these terrestrial applications, Stephens and Miller became engrossed with previously discovered research showing evidence that the eyes of hawks, eagles, and other birds of prey contain unique oil droplets that actually protect them from intensely radiated light rays (blue, violet, ultraviolet) while allowing vision-enhancing light rays (red, orange, green) to pass through. These oil droplets absorb short wavelength light rays which, in turn, reduce glare and provide heightened color contrast and definition for optimal visual acuity. Accordingly, birds of prey possess the ability to distinguish their targeted prey in natural surroundings and from great distances. Pairing the findings from their initial studies with what they learned from the bird studies, the scientists devised a methodology to incorporate the light-filtering/vision-enhancing dual-action benefits into a filtering system, using light-filtering dyes and tiny particles of zinc oxide. (Zinc oxide, which absorbs ultraviolet light, is also found in sunscreen lotions that protect the skin from sunburn.)

  9. Why Permafrost Is Thawing, Not Melting

    NASA Astrophysics Data System (ADS)

    Grosse, Guido; Romanovsky, Vladimir; Nelson, Frederick E.; Brown, Jerry; Lewkowicz, Antoni G.

    2010-03-01

    As global climate change is becoming an increasingly important political and social issue, it is essential for the cryospheric and global change research communities to speak with a single voice when using basic terminology to communicate research results and describe underlying physical processes. Experienced science communicators have highlighted the importance of using the correct terms to communicate research results to the media and general public [e.g., Akasofu, 2008; Hassol, 2008]. The consequences of scientists using improper terminology are at best oversimplification, but they more likely involve misunderstandings of the facts by the public. A glaring example of scientifically incorrect terminology appearing frequently in scientific and public communication relates to reports on the degradation of permafrost. Numerous research papers have appeared in recent years, broadly echoed in the news media, describing the “melting of permafrost,” its effects in the Arctic, and its feedbacks on climate through the carbon cycle. Although permafrost researchers have attempted to distinguish between the appropriate term “permafrost thawing” and the erroneous “permafrost melting” [e.g., van Everdingen, 2005; French, 2002], the latter is still used widely. A Web-based search using the phrase “permafrost melting” reveals hundreds of occurrences, many from highly regarded news and scientific organizations, including Reuters, New Scientist, ABC, The Guardian, Discovery News, Smithsonian magazine, the National Science Foundation, and others.

  10. The peculiar debris disk of HD 111520 as resolved by the Gemini Planet Imager

    DOE PAGES

    Draper, Zachary H.; Duchêne, Gaspard; Millar-Blanchaer, Maxwell A.; ...

    2016-07-27

    Using the Gemini Planet Imager, we have resolved the circumstellar debris disk around HD 111520 at a projected range of ~30–100 AU in both total and polarized H-band intensity. The disk is seen edge-on at a position angle of 165° along the spine of emission. A slight inclination and asymmetric warp are covariant and alter the interpretation of the observed disk emission. We employ three point-spread function subtraction methods to reduce the stellar glare and instrumental artifacts to confirm that there is a roughly 2:1 brightness asymmetry between the NW and SE extension. This specific feature makes HD 111520 themore » most extreme example of asymmetric debris disks observed in scattered light among similar highly inclined systems, such as HD 15115 and HD 106906. We further identify a tentative localized brightness enhancement and scale height enhancement associated with the disk at ~40 AU away from the star on the SE extension. We also find that the fractional polarization rises from 10% to 40% from 0".5 to 0".8 from the star. Lastly, the combination of large brightness asymmetry and symmetric polarization fraction leads us to believe that an azimuthal dust density variation is causing the observed asymmetry.« less

  11. Colonoscopy video quality assessment using hidden Markov random fields

    NASA Astrophysics Data System (ADS)

    Park, Sun Young; Sargent, Dusty; Spofford, Inbar; Vosburgh, Kirby

    2011-03-01

    With colonoscopy becoming a common procedure for individuals aged 50 or more who are at risk of developing colorectal cancer (CRC), colon video data is being accumulated at an ever increasing rate. However, the clinically valuable information contained in these videos is not being maximally exploited to improve patient care and accelerate the development of new screening methods. One of the well-known difficulties in colonoscopy video analysis is the abundance of frames with no diagnostic information. Approximately 40% - 50% of the frames in a colonoscopy video are contaminated by noise, acquisition errors, glare, blur, and uneven illumination. Therefore, filtering out low quality frames containing no diagnostic information can significantly improve the efficiency of colonoscopy video analysis. To address this challenge, we present a quality assessment algorithm to detect and remove low quality, uninformative frames. The goal of our algorithm is to discard low quality frames while retaining all diagnostically relevant information. Our algorithm is based on a hidden Markov model (HMM) in combination with two measures of data quality to filter out uninformative frames. Furthermore, we present a two-level framework based on an embedded hidden Markov model (EHHM) to incorporate the proposed quality assessment algorithm into a complete, automated diagnostic image analysis system for colonoscopy video.

  12. The Structure of a Quasi-Keplerian Accretion Disk around Magnetized Stars

    NASA Astrophysics Data System (ADS)

    Habumugisha, Isaac; Jurua, Edward; Tessema, Solomon B.; Simon, Anguma K.

    2018-06-01

    In this paper, we present the complete structure of a quasi-Keplerian thin accretion disk with an internal dynamo around a magnetized neutron star. We assume a full quasi-Keplerian disk with the azimuthal velocity deviating from the Keplerian fashion by a factor of ξ (0 < ξ < 2). In our approach, we vertically integrate the radial component of the momentum equation to obtain the radial pressure gradient equation for a thin quasi-Keplerian accretion disk. Our results show that, at large radial distance, the accretion disk behaves in a Keplerian fashion. However, close to the neutron star, pressure gradient force (PGF) largely modifies the disk structure, resulting into sudden dynamical changes in the accretion disk. The corotation radius is shifted inward (outward) for ξ > 1 (for ξ < 1), and the position of the inner edge with respect to the new corotation radius is also relocated accordingly, as compared to the Keplerian model. The resulting PGF torque couples with viscous torque (when ξ < 1) to provide a spin-down torque and a spin-up torque (when ξ > 1) while in the advective state. Therefore, neglecting the PGF, as has been the case in previous models, is a glaring omission. Our result has the potential to explain the observable dynamic consequences of accretion disks around magnetized neutron stars.

  13. Social and legal aspects of marriage in women with mental illness in India.

    PubMed

    Sharma, Indira; Tripathi, C B; Pathak, Abhishek

    2015-07-01

    The institution of marriage in Hindus is regulated by the prevailing social norms and the Hindu Marriage Act (HMA), 1955. Married women with mental illness are heavily discriminated. This paper examines the social and legal aspects of Hindu marriage in women with mental illness. The HMA, 1955 lays down the conditions for a Hindu marriage and also provides matrimonial reliefs: Nullity of marriage, restitution of conjugal rights, judicial separation and divorce. The application of the provisions of HMA in the setting mental illness is difficult and challenging. There is a wide gap between the legislative provisions of HMA, and societal value systems and attitudes towards marriage in Indian society. Societal norms are powerful and often override the legal provisions. The disparities are most glaring in the setting of mental illness in women. This is a reflection of social stigma for mental illness and patriarchal attitude towards women. Concerted efforts are needed to bridge the gap between the legislative provisions of HMA and societal value systems and attitudes toward marriage. Awareness programs regarding the nature and types of mental illness, advances in treatment and information about good outcome of severe mental illness will be helpful. Improvement in moral and religious values will overcome to some extent the negative attitudes and patriarchal mind set toward married women with mental illness.

  14. New Day for Longest-Working Mars Rover

    NASA Image and Video Library

    2018-02-16

    NASA's Mars Exploration Rover Opportunity recorded the dawn of the rover's 4,999th Martian day, or sol, with its Panoramic Camera (Pancam) on Feb. 15, 2018, yielding this processed, approximately true-color scene. The view looks across Endeavour Crater, which is about 14 miles (22 kilometers) in diameter, from the inner slope of the crater's western rim. Opportunity has driven a little over 28.02 miles (45.1 kilometers) since it landed in the Meridiani Planum region of Mars in January, 2004, for what was planned as a 90-sol mission. A sol lasts about 40 minutes longer than an Earth day. This view combines three separate Pancam exposures taken through filters centered on wavelengths of 601 microns (red), 535 microns (green) and 482 microns (blue). It was processed at Texas A&M University to correct for some of the oversaturation and glare, though it still includes some artifacts from pointing a camera with a dusty lens at the Sun. The processing includes radiometric correction, interpolation to fill in gaps in the data caused by saturation due to Sun's brightness, and warping the red and blue images to undo the effects of time passing between each of the exposures through different filters. https://photojournal.jpl.nasa.gov/catalog/PIA22221

  15. Recent advances in light outcoupling from white organic light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Gather, Malte C.; Reineke, Sebastian

    2015-01-01

    Organic light-emitting diodes (OLEDs) have been successfully introduced to the smartphone display market and have geared up to become contenders for applications in general illumination where they promise to combine efficient generation of white light with excellent color quality, glare-free illumination, and highly attractive designs. Device efficiency is the key requirement for such white OLEDs, not only from a sustainability perspective, but also because at the high brightness required for general illumination, losses lead to heating and may, thus, cause rapid device degradation. The efficiency of white OLEDs increased tremendously over the past two decades, and internal charge-to-photon conversion can now be achieved at ˜100% yield. However, the extraction of photons remains rather inefficient (typically <30%). Here, we provide an introduction to the underlying physics of outcoupling in white OLEDs and review recent progress toward making light extraction more efficient. We describe how structures that scatter, refract, or diffract light can be attached to the outside of white OLEDs (external outcoupling) or can be integrated close to the active layers of the device (internal outcoupling). Moreover, the prospects of using top-emitting metal-metal microcavity designs for white OLEDs and of tuning the average orientation of the emissive molecules within the OLED are discussed.

  16. Problems with vision associated with limitations or avoidance of driving in older populations.

    PubMed

    Satariano, William A; MacLeod, Kara E; Cohn, Theodore E; Ragland, David R

    2004-09-01

    This report examines the role of (a) disease processes affecting vision, (b) reported troubles with vision, (c) physical symptoms affecting the eyes, and (d) objective measures in reported driving limitation due to problems with eyesight among older drivers. Data for this study (N = 1,840) were obtained from participants in a community-based study of aging and physical performance in people age 55 or older in the city of Sonoma, California. Each of 16 visual conditions was assessed for impact on reported driving limitation due to eyesight by calculating a "risk" ratio. Then, prevalence of the condition was combined with the ratio to generate an attributable risk for that condition for vision-related limitations in driving. Each condition was significantly associated with reported limitations in driving due to eyesight. "Avoiding physical activity due to vision" (ratio = 3.4) and "trouble seeing steps up/down stairs" (ratio = 2.9) had the strongest association. However, "glasses/contacts required for driving" and "trouble with glare from sun/lights" had the highest attributable risks (35.8 and 29.4). The risk ratio is relevant for evaluating individuals; the attributable risk is relevant to planning countermeasures in populations. Addressing specific problems related to vision should substantially reduce driving limitations due to eyesight.

  17. Hyper-resolution hydrological modeling: Completeness of Formulation, Appropriateness of Descritization, and Physical LImits of Predictability

    NASA Astrophysics Data System (ADS)

    Ogden, F. L.

    2017-12-01

    HIgh performance computing and the widespread availabilities of geospatial physiographic and forcing datasets have enabled consideration of flood impact predictions with longer lead times and more detailed spatial descriptions. We are now considering multi-hour flash flood forecast lead times at the subdivision level in so-called hydroblind regions away from the National Hydrography network. However, the computational demands of such models are high, necessitating a nested simulation approach. Research on hyper-resolution hydrologic modeling over the past three decades have illustrated some fundamental limits on predictability that are simultaneously related to runoff generation mechanism(s), antecedent conditions, rates and total amounts of precipitation, discretization of the model domain, and complexity or completeness of the model formulation. This latter point is an acknowledgement that in some ways hydrologic understanding in key areas related to land use, land cover, tillage practices, seasonality, and biological effects has some glaring deficiencies. This presentation represents a review of what is known related to the interacting effects of precipitation amount, model spatial discretization, antecedent conditions, physiographic characteristics and model formulation completeness for runoff predictions. These interactions define a region in multidimensional forcing, parameter and process space where there are in some cases clear limits on predictability, and in other cases diminished uncertainty.

  18. All Clear for New Horizons

    NASA Image and Video Library

    2015-07-01

    This illustration shows some of the final images used to determine that the coast is clear for New Horizons' flight through the Pluto system. These images show the difference between two sets of 48 combined 10-second exposures with New Horizons Long Range Reconnaissance Imager (LORRI) camera, taken at 8:40 UTC and 10:25 UTC on June 26, 2015, from a range of 21.5 million kilometers (approximately 13 million miles) to Pluto. The known small moons, Nix, Hydra, Kerberos and Styx, are visible as adjacent bright and dark pairs of dots, due to their motion in the 105 minutes between the two image sets. The images have been extensively processed to remove the glare and "ghosts" (i.e., lens flare) from Pluto and Charon, and also to remove background stars, though many of the brighter stars are imperfectly removed and appear as irregular bright and dark blobs. These and other similar sets of images demonstrate that there are no previously unknown moons brighter than 15 times fainter than Styx (the faintest known moon) in the region outside of Charon's orbit, or brighter than five times fainter than Styx in the region between Charon's orbit and a few thousand kilometers above Pluto's surface. http://photojournal.jpl.nasa.gov/catalog/PIA19695

  19. AAPM/RSNA physics tutorial for residents: physics of flat-panel fluoroscopy systems: Survey of modern fluoroscopy imaging: flat-panel detectors versus image intensifiers and more.

    PubMed

    Nickoloff, Edward Lee

    2011-01-01

    This article reviews the design and operation of both flat-panel detector (FPD) and image intensifier fluoroscopy systems. The different components of each imaging chain and their functions are explained and compared. FPD systems have multiple advantages such as a smaller size, extended dynamic range, no spatial distortion, and greater stability. However, FPD systems typically have the same spatial resolution for all fields of view (FOVs) and are prone to ghosting. Image intensifier systems have better spatial resolution with the use of smaller FOVs (magnification modes) and tend to be less expensive. However, the spatial resolution of image intensifier systems is limited by the television system to which they are coupled. Moreover, image intensifier systems are degraded by glare, vignetting, spatial distortions, and defocusing effects. FPD systems do not have these problems. Some recent innovations to fluoroscopy systems include automated filtration, pulsed fluoroscopy, automatic positioning, dose-area product meters, and improved automatic dose rate control programs. Operator-selectable features may affect both the patient radiation dose and image quality; these selectable features include dose level setting, the FOV employed, fluoroscopic pulse rates, geometric factors, display software settings, and methods to reduce the imaging time. © RSNA, 2011.

  20. Drivers of workplace discrimination against people with disabilities: the utility of Attribution Theory.

    PubMed

    Chan, Fong; McMahon, Brian T; Cheing, Gladys; Rosenthal, David A; Bezyak, Jill

    2005-01-01

    The purpose of this paper was to determine what drives workplace discrimination against people with disabilities. These findings are then compared to available literature on attribution theory, which concerns itself with public perceptions of the controllability and stability of various impairments. The sample included 35,763 allegations of discriminations filed by people with disabilities under the employment provisions of the Americans with Disabilities Act. Group A included impairments deemed by Corrigan et al. [1988] to be uncontrollable but stable: visual impairment (representing 13% of the total allegations in this study), cancer (12%), cardiovascular disease (19%), and spinal cord injuries (5%). The controllable but unstable impairments in group B included depression (38%), schizophrenia (2%), alcohol and other drug abuse (4%), and HIV/AIDS (7%). The Equal Employment Opportunity Commission had resolved all allegations in terms of merit Resolutions (a positive finding of discrimination) and Resolutions without merit. Allegations of workplace discrimination were found to center mainly on hiring, discharge, harassment, and reasonable accommodation issues. Perceived workplace discrimination (as measured by allegations filed with EEOC) does occur at higher levels in Group B, especially when serious issues involving discharge and disability harassment are involved. With the glaring exception of HIV/AIDS, however, actual discrimination (as measured by EEOC merit Resolutions) occurs at higher levels for Group A.

  1. ARC-1989-A89-7042

    NASA Image and Video Library

    1989-08-11

    P-34578 BW One of two new ring arcs, or partial rings, discovered by Voyager 2, is faintly visible just outside the orbit of the Neptunian moon 1989N4.The 155-second exposure taken by the spacecraft's narrow-angle camera shows the glare of an overexposed Neptune to the right of the moon and ring arc. The two bright streaks below the moon and ring arc are stars. The ring arc is approximately 50,000 kilometers (30,000 miles) long. The second ring arc, not apparent here, is about 10,000 kilometers (6,000 miles) long and is assoiciated with moon 1989N3. The ring arc, along with 1989N4, orbits about 62,000 kilometers (38,000 miles) from the planet's cloud tops. Astronomers long suspected the existence of such an irregular ring system around Neptune. Data from repeated ground-based observations hinted at the existence of irregular strands of partial rings orbiting Neptune. Voyager's photographs of the ring arcs are the first photographic evidence that such a ring system exists. Voyager scientists said the ring arcs may be comprised of debris associated with the nearby moons, or may be the remnants of moons that have been torn apart or ground down through collisions. Close-up studies of the ring arcs by Voyager 2 will help determine their composition.

  2. Sun Exposure, Sun-Related Symptoms, and Sun Protection Practices in an African Informal Traditional Medicines Market.

    PubMed

    Wright, Caradee Y; Reddy, Tarylee; Mathee, Angela; Street, Renée A

    2017-09-28

    Informal workers in African market trade have little formal protection against sun exposure. We aimed to examine sun exposure, sun-related symptoms, and sun protection practices in an informal occupational setting. Trained fieldworkers asked 236 workers in the Warwick Junction market about their workplace, skin and eye sensitivity and skin colour, symptoms faced at work during the summer due to heat, and preventive measures. Data were analyzed using univariate logistic regression to assess the effect of gender and the risk of experiencing symptoms to sun exposure in relation to pre-existing diseases and perception of sun exposure as a hazard. Of the 236 participants, 234 were Black African and 141 (59.7%) were female. Portable shade was the most commonly used form of sun protection (69.9%). Glare from the sun (59.7%) and excessive sweating (57.6%) were commonly reported sun-related health symptoms. The use of protective clothing was more prevalent among those who perceived sun exposure as a hazard ( p = 0.003). In an informal occupational setting, sun exposure was high. Protective clothing and portable shade to eliminate heat and bright light were self-implemented. Action by local authorities to protect informal workers should consider sun exposure to support workers in their efforts to cope in hot weather.

  3. Tracker-assisted versus manual ablation zone centration in laser in situ keratomileusis for myopia and astigmatism.

    PubMed

    Pineros, Oscar E

    2002-01-01

    Eye tracker systems have been developed concomitantly with small scanning beams to theoretically reduce ablation zone decentration and for accurate registration of all the laser pulses on the cornea. The purpose of the study was to compare the tracker-assisted with the manual centration method. Twenty-five patients (48 eyes) with myopia and/or astigmatism had laser in situ keratomileusis (LASIK) between August 1998 and February 1999 with the Technolas 117C laser. Twenty patients (38 eyes, 80%) were available for follow-up at 3 months after surgery. Eyes were assigned randomly to one of two ablation zone centration methods: Group 1: Tracker-assisted (20 eyes), Group 2: Manual (18 eyes). Mean distance between the ablation zone center and the pupillary center in the tracker-assisted centration group was 0.55 +/- 0.30 mm (range, 0.10 to 1.4 mm), and in the manual centration group, 0.43 +/- 0.23 mm (range, 0.10 to 1.0 mm) (P = .177). There was no statistically significant difference in postoperative contrast sensitivity, glare, and Topographical Corneal Surface Regularity Index (SRI) between the two groups. We obtained good results with both centration methods. We did not find superiority of the tracker-assisted over manual regarding ablation zone centration, vision quality, or regularity of the ablation.

  4. The virulence–transmission trade-off in vector-borne plant viruses: a review of (non-)existing studies

    PubMed Central

    Froissart, R.; Doumayrou, J.; Vuillaume, F.; Alizon, S.; Michalakis, Y.

    2010-01-01

    The adaptive hypothesis invoked to explain why parasites harm their hosts is known as the trade-off hypothesis, which states that increased parasite transmission comes at the cost of shorter infection duration. This correlation arises because both transmission and disease-induced mortality (i.e. virulence) are increasing functions of parasite within-host density. There is, however, a glaring lack of empirical data to support this hypothesis. Here, we review empirical investigations reporting to what extent within-host viral accumulation determines the transmission rate and the virulence of vector-borne plant viruses. Studies suggest that the correlation between within-plant viral accumulation and transmission rate of natural isolates is positive. Unfortunately, results on the correlation between viral accumulation and virulence are very scarce. We found only very few appropriate studies testing such a correlation, themselves limited by the fact that they use symptoms as a proxy for virulence and are based on very few viral genotypes. Overall, the available evidence does not allow us to confirm or refute the existence of a transmission–virulence trade-off for vector-borne plant viruses. We discuss the type of data that should be collected and how theoretical models can help us refine testable predictions of virulence evolution. PMID:20478886

  5. Clinical study on the treatment of vertigo by ant vertigo

    NASA Astrophysics Data System (ADS)

    Liu, Xiaobin; Li, Chongxian; Hao, Shaojun; Lian, Linlin; Chen, Weiliang; Wang, Hongyu; Guan, Zhijiang; Zhang, Zhengchen

    2018-04-01

    To observe the clinical curative effect of antiglare granule in the treatment of hypertension, cerebral arteriosclerosis, vertebrobasilar artery insufficiency, Meniere's disease, autonomic dysfunction caused by vertigo etc, the patients with vertigo were randomly divided into 300 cases of cerebral arteriosclerosis, vertebral basilar artery insufficiency, Meniere's disease into three groups, treatment group: control group 1, 2 groups of. 3 times a day, 30 days for a course of treatment, once a two treatment, observation and treatment effect. Control group: conventional doses of Yangxue Qingnao Granule, enteric coated aspirin treatment ibid. After 2 courses of treatment were observed and recorded the key concept of vertigo degree change number. Compare the outcome of TCM symptom medication after February, the total effective rate of treatment group was 96%, 1 in the control group the total efficiency of 69.7%, 2 in the control group the total efficiency of 71.7%, the treatment group curative effect on the treatment of hypertension, cerebral arteriosclerosis, vertebral basilar artery insufficiency vertigo, Meniere's disease, head weight light, walking foot stable curative effect is better than that of Yangxue Qingnao Granule, enteric coated aspirin effect. Aanti glare granule in the treatment of hypertension, cerebral arteriosclerosis and vertebral basilar artery insufficiency, Meniere's disease, autonomic dysfunction caused by vertigo has good clinical curative effect.

  6. THE TRIFID NEBULA: STELLAR SIBLING RIVALRY

    NASA Technical Reports Server (NTRS)

    2002-01-01

    This NASA Hubble Space Telescope image of the Trifid Nebula reveals a stellar nursery being torn apart by radiation from a nearby, massive star. The picture also provides a peek at embryonic stars forming within an ill-fated cloud of dust and gas, which is destined to be eaten away by the glare from the massive neighbor. This stellar activity is a beautiful example of how the life cycles of stars like our Sun is intimately connected with their more powerful siblings. The Hubble image shows a small part of a dense cloud of dust and gas, a stellar nursery full of embryonic stars. This cloud is about 8 light-years away from the nebula's central star, which is beyond the top of this picture. Located about 9,000 light-years from Earth, the Trifid resides in the constellation Sagittarius. A stellar jet [the thin, wispy object pointing to the upper left] protrudes from the head of a dense cloud and extends three-quarters of a light-year into the nebula. The jet's source is a very young stellar object that lies buried within the cloud. Jets such as this are the exhaust gases of star formation. Radiation from the massive star at the center of the nebula is making the gas in the jet glow, just as it causes the rest of the nebula to glow. The jet in the Trifid is a 'ticker tape,' telling the history of one particular young stellar object that is continuing to grow as its gravity draws in gas from its surroundings. But this particular ticker tape will not run for much longer. Within the next 10,000 years the glare from the central, massive star will continue to erode the nebula, overrunning the forming star, and bringing its growth to an abrupt and possibly premature end. Another nearby star may have already faced this fate. The Hubble picture shows a 'stalk' [the finger-like object] pointing from the head of the dense cloud directly toward the star that powers the Trifid. This stalk is a prominent example of the evaporating gaseous globules, or 'EGGs,' that were seen previously in the Eagle Nebula, another star-forming region photographed by Hubble. The stalk has survived because at its tip there is a knot of gas that is dense enough to resist being eaten away by the powerful radiation. Reflected starlight at the tip of the EGG may be due to light from the Trifid's central star, or from a young stellar object buried within the EGG. Similarly, a tiny spike of emission pointing outward from the EGG looks like a small stellar jet. Hubble astronomers are tentatively interpreting this jet as the last gasp from a star that was cut off from its supply lines 100,000 years ago. The images were taken Sept. 8, 1997 through filters that isolate emission from hydrogen atoms, ionized sulfur atoms, and doubly ionized oxygen atoms. The images were combined in a single color composite picture. While the resulting picture is not true color, it is suggestive of what a human eye might see. Credits: NASA and Jeff Hester (Arizona State University)

  7. Multifocal versus monofocal intraocular lenses after cataract extraction.

    PubMed

    de Silva, Samantha R; Evans, Jennifer R; Kirthi, Varo; Ziaei, Mohammed; Leyland, Martin

    2016-12-12

    Good unaided distance visual acuity (VA) is now a realistic expectation following cataract surgery and intraocular lens (IOL) implantation. Near vision, however, still requires additional refractive power, usually in the form of reading glasses. Multiple optic (multifocal) IOLs are available which claim to allow good vision at a range of distances. It is unclear whether this benefit outweighs the optical compromises inherent in multifocal IOLs. To assess the visual effects of multifocal IOLs in comparison with the current standard treatment of monofocal lens implantation. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2016), Embase (January 1980 to June 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 13 June 2016. All randomised controlled trials comparing a multifocal IOL of any type with a monofocal IOL as control were included. Both unilateral and bilateral implantation trials were included. We also considered trials comparing multifocal IOLs with "monovision" whereby one eye is corrected for distance vision and one eye corrected for near vision. We used standard methodological procedures expected by Cochrane. We assessed the 'certainty' of the evidence using GRADE. We found 20 eligible trials that enrolled 2230 people with data available on 2061 people (3194 eyes). These trials were conducted in Europe (13), China (three), USA (one), Middle East (one), India (one) and one multicentre study in Europe and the USA. Most of these trials compared multifocal with monofocal lenses; two trials compared multifocal lenses with monovision. There was considerable variety in the make and model of lenses implanted. Overall we considered the trials at risk of performance and detection bias because it was difficult to mask participants and outcome assessors. It was also difficult to assess the role of reporting bias.There was moderate-certainty evidence that the distance acuity achieved with multifocal lenses was not different to that achieved with monofocal lenses (unaided VA worse than 6/6: pooled RR 0.96, 95% confidence interval (CI) 0.89 to 1.03; eyes = 682; studies = 8). People receiving multifocal lenses may achieve better near vision (RR for unaided near VA worse than J3/J4 was 0.20, 95% CI 0.07 to 0.58; eyes = 782; studies = 8). We judged this to be low-certainty evidence because of risk of bias in the included studies and high heterogeneity (I 2 = 93%) although all included studies favoured multifocal lenses with respect to this outcome.People receiving multifocal lenses may be less spectacle dependent (RR 0.63, 95% CI 0.55 to 0.73; eyes = 1000; studies = 10). We judged this to be low-certainty evidence because of risk of bias and evidence of publication bias (skewed funnel plot). There was also high heterogeneity (I 2 = 67%) but all studies favoured multifocal lenses. We did not additionally downgrade for this.Adverse subjective visual phenomena were more prevalent and more troublesome in participants with a multifocal IOL compared with monofocals (RR for glare 1.41, 95% CI 1.03 to 1.93; eyes = 544; studies = 7, low-certainty evidence and RR for haloes 3.58, 95% CI 1.99 to 6.46; eyes = 662; studies = 7; moderate-certainty evidence).Two studies compared multifocal lenses with monovision. There was no evidence for any important differences in distance VA between the groups (mean difference (MD) 0.02 logMAR, 95% CI -0.02 to 0.06; eyes = 186; studies = 1), unaided intermediate VA (MD 0.07 logMAR, 95% CI 0.04 to 0.10; eyes = 181; studies = 1) and unaided near VA (MD -0.04, 95% CI -0.08 to 0.00; eyes = 186; studies = 1) compared with people receiving monovision. People receiving multifocal lenses were less likely to be spectacle dependent (RR 0.40, 95% CI 0.30 to 0.53; eyes = 262; studies = 2) but more likely to report problems with glare (RR 1.41, 95% CI 1.14 to 1.73; eyes = 187; studies = 1) compared with people receiving monovision. In one study, the investigators noted that more people in the multifocal group underwent IOL exchange in the first year after surgery (6 participants with multifocal vs 0 participants with monovision). Multifocal IOLs are effective at improving near vision relative to monofocal IOLs although there is uncertainty as to the size of the effect. Whether that improvement outweighs the adverse effects of multifocal IOLs, such as glare and haloes, will vary between people. Motivation to achieve spectacle independence is likely to be the deciding factor.

  8. Strain characterization of embedded aerospace smart materials using shearography

    NASA Astrophysics Data System (ADS)

    Anisimov, Andrei G.; Müller, Bernhard; Sinke, Jos; Groves, Roger M.

    2015-04-01

    The development of smart materials for embedding in aerospace composites provides enhanced functionality for future aircraft structures. Critical flight conditions like icing of the leading edges can affect the aircraft functionality and controllability. Hence, anti-icing and de-icing capabilities are used. In case of leading edges made of fibre metal laminates heater elements can be embedded between composite layers. However this local heating causes strains and stresses in the structure due to the different thermal expansion coefficients of the different laminated materials. In order to characterize the structural behaviour during thermal loading full-field strain and shape measurement can be used. In this research, a shearography instrument with three spatially-distributed shearing cameras is used to measure surface displacement gradients which give a quantitative estimation of the in- and out-of-plane surface strain components. For the experimental part, two GLARE (Glass Laminate Aluminum Reinforced Epoxy) specimens with six different embedded copper heater elements were manufactured: two copper mesh shapes (straight and S-shape), three connection techniques (soldered, spot welded and overlapped) and one straight heater element with delaminations. The surface strain behaviour of the specimens due to thermal loading was measured and analysed. The comparison of the connection techniques of heater element parts showed that the overlapped connection has the smallest effect on the surface strain distribution. Furthermore, the possibility of defect detection and defect depth characterisation close to the heater elements was also investigated.

  9. Relationship between macular pigment and visual function in subjects with early age-related macular degeneration.

    PubMed

    Akuffo, Kwadwo Owusu; Nolan, John M; Peto, Tunde; Stack, Jim; Leung, Irene; Corcoran, Laura; Beatty, Stephen

    2017-02-01

    To investigate the relationship between macular pigment (MP) and visual function in subjects with early age-related macular degeneration (AMD). 121 subjects with early AMD enrolled as part of the Central Retinal Enrichment Supplementation Trial (CREST; ISRCTN13894787) were assessed using a range of psychophysical measures of visual function, including best corrected visual acuity (BCVA), letter contrast sensitivity (CS), mesopic and photopic CS, mesopic and photopic glare disability (GD), photostress recovery time (PRT), reading performance and subjective visual function, using the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25). MP was measured using customised heterochromatic flicker photometry. Letter CS, mesopic and photopic CS, photopic GD and mean reading speed were each significantly (p<0.05) associated with MP across a range of retinal eccentricities, and these statistically significant relationships persisted after controlling for age, sex and cataract grade. BCVA, NEI VFQ-25 score, PRT and mesopic GD were unrelated to MP after controlling for age, sex and cataract grade (p>0.05, for all). MP relates positively to many measures of visual function in unsupplemented subjects with early AMD. The CREST trial will investigate whether enrichment of MP influences visual function among those afflicted with this condition. ISRCTN13894787. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Realistic anomaly-mediated supersymmetry breaking

    NASA Astrophysics Data System (ADS)

    Chacko, Zacharia; Luty, Markus A.; Maksymyk, Ivan; Pontón, Eduardo

    2000-03-01

    We consider supersymmetry breaking communicated entirely by the superconformal anomaly in supergravity. This scenario is naturally realized if supersymmetry is broken in a hidden sector whose couplings to the observable sector are suppressed by more than powers of the Planck scale, as occurs if supersymmetry is broken in a parallel universe living in extra dimensions. This scenario is extremely predictive: soft supersymmetry breaking couplings are completely determined by anomalous dimensions in the effective theory at the weak scale. Gaugino and scalar masses are naturally of the same order, and flavor-changing neutral currents are automatically suppressed. The most glaring problem with this scenario is that slepton masses are negative in the minimal supersymmetric standard model. We point out that this problem can be simply solved by coupling extra Higgs doublets to the leptons. Lepton flavor-changing neutral currents can be naturally avoided by approximate symmetries. We also describe more speculative solutions involving compositeness near the weak scale. We then turn to electroweak symmetry breaking. Adding an explicit μ term gives a value for Bμ that is too large by a factor of ~ 100. We construct a realistic model in which the μ term arises from the vacuum expectation value of a singlet field, so all weak-scale masses are directly related to m3/2. We show that fully realistic electroweak symmetry breaking can occur in this model with moderate fine-tuning.

  11. Small-Gauge Pars Plana Vitrectomy for the Management of Symptomatic Posterior Vitreous Detachment after Phacoemulsification and Multifocal Intraocular Lens Implantation: A Pilot Study from the Pan-American Collaborative Retina Study Group

    PubMed Central

    Navarro, Rodrigo M.; Machado, Leonardo M.; Maia, Ossires; Wu, Lihteh; Farah, Michel E.; Magalhaes, Octaviano; Arevalo, J. Fernando; Maia, Mauricio

    2015-01-01

    Purpose. To determine the efficacy of 23-gauge pars plana vitrectomy (PPV) for symptomatic posterior vitreous detachment (PVD) on visual acuity (VA) and quality after multifocal intraocular lenses (IOLs). Methods. In this prospective case series, patients who developed symptomatic PVD and were not satisfied with visual quality due to floaters and halos after multifocal IOL implantation underwent PPV. Examinations included LogMAR uncorrected visual acuity (UCVA), intraocular pressure, biomicroscopy, and indirect ophthalmoscopy at baseline and 1, 7, 30, and 180 days postoperatively. Ultrasonography and aberrometry were performed. The Visual Functioning Questionnaire 25 (VFQ-25) was administered preoperatively and at 30 days postoperatively. Both the postoperative UCVA and questionnaire results were compared to preoperative findings using the Wilcoxon test. Results. Sixteen eyes of 8 patients were included. VA significantly improved from 0.17 to 0.09 postoperatively (P = 0.017). All patients reported improvement of halos, glare, and floaters. VFQ-25 scores significantly improved in general vision (P = 0.023), near activities (P = 0.043), distance activities (P = 0.041), mental health (P = 0.011), role difficulties (P = 0.042), and driving (P = 0.016). Conclusion. PPV may increase UCVA and quality of vision in patients with bilateral multifocal IOLs and symptomatic PVD. Larger studies are advised. PMID:26504590

  12. External shading devices for energy efficient building

    NASA Astrophysics Data System (ADS)

    Shahdan, M. S.; Ahmad, S. S.; Hussin, M. A.

    2018-02-01

    External shading devices on a building façade is an important passive design strategy as they reduce solar radiation. Although studies have proven the benefits of external shading devices, many are designed solely for aesthetic purposes without fully considering its high potential to reduce solar radiation and glare. Furthermore, explorations into shading devices by the design team are mostly left too late in the design development phases. Hence, the paper looks into the effectiveness of external shading devices on a building towards more energy efficient building. The study aims to analyse the effects of various configurations of external shading devices towards the energy consumption of a case study building based on computer simulations. This study uses Building Information Modelling (BIM) through Autodesk Revit software as simulation tool. The constant variables for the simulation are the orientation of the building, types of glazing used by the building and the internal loads of the building. Whereas, the manipulated variable is the types of shading device used. The data were sorted according to the categories and translated into a chart. Analysis of the findings indicate that shading devices with different configurations show significant results in the energy consumption and the best configuration is the egg-crate shading devices. The study recommends that the consideration for shading device as a passive design strategy needs to be developed at the early stage of the building design.

  13. Barriers and benefits: implications of artificial night-lighting for the distribution of common bats in Britain and Ireland

    PubMed Central

    Mathews, Fiona; Roche, Niamh; Aughney, Tina; Jones, Nicholas; Day, Julie; Baker, James; Langton, Steve

    2015-01-01

    Artificial lighting is a particular problem for animals active at night. Approximately 69% of mammal species are nocturnal, and one-third of these are bats. Due to their extensive movements—both on a nightly basis to exploit ephemeral food supplies, and during migration between roosts—bats have an unusually high probability of encountering artificial light in the landscape. This paper reviews the impacts of lighting on bats and their prey, exploring the direct and indirect consequences of lighting intensity and spectral composition. In addition, new data from large-scale surveys involving more than 265 000 bat calls at more than 600 locations in two countries are presented, showing that prevalent street-lighting types are not generally linked with increased activity of common and widespread bat species. Such bats, which are important to ecosystem function, are generally considered ‘light-attracted’ and likely to benefit from the insect congregations that form at lights. Leisler's bat (Nyctalus leisleri) may be an exception, being more frequent in lit than dark transects. For common pipistrelle bats (Pipistrellus pipistrellus), lighting is negatively associated with their distribution on a landscape scale, but there may be local increases in habitats with good tree cover. Research is now needed on the impacts of sky glow and glare for bat navigation, and to explore the implications of lighting for habitat matrix permeability. PMID:25780236

  14. Resveratrol Based Oral Nutritional Supplement Produces Long-Term Beneficial Effects on Structure and Visual Function in Human Patients

    PubMed Central

    Richer, Stuart; Patel, Shana; Sockanathan, Shivani; Ulanski, Lawrence J.; Miller, Luke; Podella, Carla

    2014-01-01

    Background: Longevinex® (L/RV) is a low dose hormetic over-the-counter (OTC) oral resveratrol (RV) based matrix of red wine solids, vitamin D3 and inositol hexaphosphate (IP6) with established bioavailability, safety, and short-term efficacy against the earliest signs of human atherosclerosis, murine cardiac reperfusion injury, clinical retinal neovascularization, and stem cell survival. We previously reported our short-term findings for dry and wet age-related macular degeneration (AMD) patients. Today we report long term (two to three year) clinical efficacy. Methods: We treated three patients including a patient with an AMD treatment resistant variant (polypoidal retinal vasculature disease). We evaluated two clinical measures of ocular structure (fundus autofluorescent imaging and spectral domain optical coherence extended depth choroidal imaging) and qualitatively appraised changes in macular pigment volume. We further evaluated three clinical measures of visual function (Snellen visual acuity, contrast sensitivity, and glare recovery to a cone photo-stress stimulus). Results: We observed broad bilateral improvements in ocular structure and function over a long time period, opposite to what might be expected due to aging and the natural progression of the patient’s pathophysiology. No side effects were observed. Conclusions: These three cases demonstrate that application of epigenetics has long-term efficacy against AMD retinal disease, when the retinal specialist has exhausted other therapeutic modalities. PMID:25329968

  15. Bridges, Lights, and Hubris: Examples of Excessive Light Pollution

    NASA Astrophysics Data System (ADS)

    Upgren, A. R.

    2000-12-01

    Recently many new lighting projects have been planned, frequently for the purpose of bringing attention to a tower or bridge, with the intent of promoting it as a tourist attraction. Examples of this form of light pollution are illustrated here. Many proceed with plans to mount new floodlights pointed upward with most of the light shining directly up into the sky. At least three of the more excessive among them have been tabled or aborted upon objections by members of the International Dark-Sky Association and other environmental groups. Opposition to the most ill-conceived of these plans centers on waste of money and energy, excessive fatalities among migratory birds, damage to the aesthetic beauty and study of the night sky, and (near seacoasts) damage to the nesting and hatching of sea turtles. Constructive opposition to lighting excess and glare may include the substitution of tracer lights, such as the ones that adorn the great suspension bridges of New York and San Francisco. Tracer lights using full-cutoff shielding outline a structure much as lights on a Christmas tree delineate its shape, but floodlights in the mix render a washed-out effect similar to a Christmas tree in broad daylight. The AAS Committee on Light Pollution, Radio Interference, and Space Debris encourages a greater role for the Society in coordinating opposition to such projects, which is too often local and inexperienced.

  16. Resveratrol based oral nutritional supplement produces long-term beneficial effects on structure and visual function in human patients.

    PubMed

    Richer, Stuart; Patel, Shana; Sockanathan, Shivani; Ulanski, Lawrence J; Miller, Luke; Podella, Carla

    2014-10-17

    Longevinex® (L/RV) is a low dose hormetic over-the-counter (OTC) oral resveratrol (RV) based matrix of red wine solids, vitamin D3 and inositol hexaphosphate (IP6) with established bioavailability, safety, and short-term efficacy against the earliest signs of human atherosclerosis, murine cardiac reperfusion injury, clinical retinal neovascularization, and stem cell survival. We previously reported our short-term findings for dry and wet age-related macular degeneration (AMD) patients. Today we report long term (two to three year) clinical efficacy. We treated three patients including a patient with an AMD treatment resistant variant (polypoidal retinal vasculature disease). We evaluated two clinical measures of ocular structure (fundus autofluorescent imaging and spectral domain optical coherence extended depth choroidal imaging) and qualitatively appraised changes in macular pigment volume. We further evaluated three clinical measures of visual function (Snellen visual acuity, contrast sensitivity, and glare recovery to a cone photo-stress stimulus). We observed broad bilateral improvements in ocular structure and function over a long time period, opposite to what might be expected due to aging and the natural progression of the patient's pathophysiology. No side effects were observed. These three cases demonstrate that application of epigenetics has long-term efficacy against AMD retinal disease, when the retinal specialist has exhausted other therapeutic modalities.

  17. [Influence of different multifocal intraocular lens concepts on retinal stray light parameters].

    PubMed

    Ehmer, A; Rabsilber, T M; Mannsfeld, A; Sanchez, M J; Holzer, M P; Auffarth, G U

    2011-10-01

    Multifocal intraocular lenses (MIOL) are known to induce various photic phenomena depending on the optical principle. The aim of this study was to investigate the correlation between stray light measurements performed with the C-Quant (Oculus, Germany) and the results of a subjective patient questionnaire. In this study three different MIOLs were compared: AMO ReZoom (refractive design, n=10), AMO ZM900 (diffractive design, n=10) and Oculentis Mplus (near segment design, n=10). Cataract and refractive patients were enrolled in the study. Functional results were evaluated at least 3 months postoperatively followed by stray light measurements and a subjective questionnaire. Surgery was performed for all patients without complications. The three groups were matched for age, IOL power and corrected distance visual acuity (CDVA). Significantly different stray light (median) values log(s) were found (Kruskal-Wallis test, p<0.05): 1.12 log (refractive), 1.13 log (segment) and 1.28 log (diffractive). The subjective questionnaire did not show differences in glare perception but refractive MIOL patients noticed more halos surrounding light sources than the diffractive and segment MIOL patients. Stray light and subjective photopic phenomena do not show any basic correlation. Measurements in patients with refractive MIOLs showed less stray light than near segment or diffractive MIOLs. However, refractive MIOLs induced more halos compared to the other groups analyzed.

  18. Too much coronary angioplasty in the USA?: less may be better - the conflicting roles of inexactness of medicine as a science, asymmetric information, technologic imperative, unnecessary care and ethicomedicinomics in US healthcare.

    PubMed

    Onuigbo, M A C; Agbasi, N

    2014-09-01

    US healthcare expenditure per capita far exceeds that of any other nation in the world. Indeed, over the last 15 years, the USA has distantly surpassed most countries in the developed world in total healthcare expenditures per capita with the USA now spending 17.4% of its gross domestic product (GDP) on healthcare ($7960 per capita), compared with only 8.5% of GDP in Japan ($2878 per capita), a distant second. Consequently, by current projections, the US healthcare bill will have ballooned from $2.5 trillion in 2009 to over $4.6 trillion by 2020. Such spending growth rates are unsustainable and the system would soon go broke if not corrected. The drivers of these spending growth rates in US healthcare are several and varied. Indeed, in September 2012, the Institute of Medicine reported that US healthcare squandered $750 billion in 2009 through unneeded care, Byzantine paperwork, fraud and other wasteful activities. Recently, the question was raised as to whether we have too much coronary angioplasty in the USA. In this analysis, we examine these and other various related aspects of US healthcare, make comparisons with other national healthcare delivery systems, and suggest several reengineering modalities to help fix these compellingly glaring glitches and maladies of US healthcare. © 2014 John Wiley & Sons Ltd.

  19. Visual characteristics of LED display pushbuttons for avionic applications

    NASA Astrophysics Data System (ADS)

    Vanni, Paolo; Isoldi, Felice

    1991-08-01

    Programmable LED matrix display push buttons may greatly increase the performances of the computer-based avionic systems. The number of switches in a control panel can be reduced by a factor of 10 or more. This leads to a reduction in weight and size of the control instrumentations and in shorter response time of pilots. This work deals with the study and the optimization of visual performances of these displays in a configuration requiring a low- power consumption and Night Vision Goggles (NVG) compatibility. In considering displays for avionic applications, it is important to take into account sunlight readability. Visibility problems may arise in high ambient illumination. Up to now the only contributions usually considered for reduction of visibility are the diffused and specular reflected luminances that predominate with the sun behind the pilot. But there is another critical condition--the sun in front of the pilot. In this case the equivalent veiling glare predominates. Display performances and contrast enhancement filter characteristics must be optimized to find a compromise between these two extreme ambient conditions. Considering a keyboard with 10 push buttons, with two lines of four characters each and a power consumption less than 14 W with 40 of LEDs on, the authors have obtained good sunlight readability, choosing an optimized combination of NVG and contrast enhancement filter and LED matrix display.

  20. Sociocultural factors influencing breastfeeding practices in two slums in Nairobi, Kenya.

    PubMed

    Wanjohi, Milka; Griffiths, Paula; Wekesah, Frederick; Muriuki, Peter; Muhia, Nelson; Musoke, Rachel N; Fouts, Hillary N; Madise, Nyovani J; Kimani-Murage, Elizabeth W

    2016-01-01

    Despite numerous interventions promoting optimal breastfeeding practices in Kenya, pockets of suboptimal breastfeeding practices are documented in Kenya's urban slums. This paper describes cultural and social beliefs and practices that influence breastfeeding in two urban slums in Nairobi, Kenya. Qualitative data were collected in Korogocho and Viwandani slums through 10 focus group discussions and 19 in-depth interviews with pregnant, breastfeeding women and community health volunteers and 11 key-informant interviews with community leaders. Interviews were audiotaped, transcribed verbatim, coded in NVIVO and analyzed thematically. Social and cultural beliefs and practices that result to suboptimal breastfeeding practices were highlighted including; considering colostrum as 'dirty' or 'curdled milk', a curse 'bad omen' associated with breastfeeding while engaging in extra marital affairs, a fear of the 'evil eye' (malevolent glare which is believed to be a curse associated with witchcraft) when breastfeeding in public and breastfeeding being associated with sagging breasts. Positive social and cultural beliefs were also identified including the association of breast milk with intellectual development and good child health. The beliefs and practices were learnt mainly from spouses, close relatives and peers. Interventions promoting behavior change with regards to breastfeeding should focus on dispelling the beliefs and practices that result to suboptimal breastfeeding practices and to build on the positive ones, while involving spouses and other family members as they are important sources of information on breastfeeding. ISRCTN83692672: December 2013 (retrospectively registered).

  1. Macular Carotenoid Supplementation Improves Visual Performance, Sleep Quality, and Adverse Physical Symptoms in Those with High Screen Time Exposure

    PubMed Central

    Stringham, James M.; Stringham, Nicole T.; O’Brien, Kevin J.

    2017-01-01

    The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased “screen time” (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months’ supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures (p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo (p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation. PMID:28661438

  2. Macular Carotenoid Supplementation Improves Visual Performance, Sleep Quality, and Adverse Physical Symptoms in Those with High Screen Time Exposure.

    PubMed

    Stringham, James M; Stringham, Nicole T; O'Brien, Kevin J

    2017-06-29

    The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased "screen time" (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months' supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures ( p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo ( p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation.

  3. Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses

    PubMed Central

    Vilar, César; Hida, Wilson Takashi; de Medeiros, André Lins; Magalhães, Klayny Rafaella Pereira; de Moraes Tzelikis, Patrick Frensel; Chaves, Mario Augusto Pereira Dias; Motta, Antônio Francisco Pimenta; Carricondo, Pedro Carlos; Alves, Milton Ruiz; Nosé, Walton

    2017-01-01

    Purpose To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye. Methods This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes) who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA) and uncorrected intermediate (60 cm) and near (at 40 cm) visual acuity; contrast sensitivity (CS) and visual defocus curve. Results Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision. Conclusion Both lens combinations were able to provide good near, intermediate and distance vision, with the trifocal group showing significantly better performance at intermediate distances and better CS under photopic conditions. PMID:28814826

  4. Educational Opportunities for the 2014 Opposition of Mars

    NASA Astrophysics Data System (ADS)

    Albin, Edward F.

    2013-10-01

    Mars reaches opposition and is well placed for public viewing on April 8, 2014 at 20:57 UT. The opposition timeline and educational opportunities are considered, with emphasis on programs presented at the Fernbank Science Center in Atlanta, Georgia. Educational programs include a planetarium presentation, observations of Mars through telescopes, and activities associated with the ongoing Curiosity Rover (MSL) / anticipated Mars Atmosphere and Volatile Evolution (MAVEN) spacecraft. When at opposition in 2014, Mars will have an apparent diameter of 15.1 arcseconds and will be visible in the evening sky for a little over a year until it is lost in the glare of the Sun in late April 2015. At closest approach, the planet will be a bit more than 57 million miles (92 million kilometers) from the Earth. Mars is especially well placed in the evening sky for viewing between the months of March and May of 2014. During this period, the planet can be found in retrograde motion within the constellation pattern of Virgo. Fernbank Science Center will offer public viewing of Mars through the observatory’s 36-inch (0.9 meter) reflecting telescope on Thursday and Friday evenings. The observatory is open immediately after the evening planetarium program. We anticipate showing a fulldome planetarium presentation about Mars entitled, "Mars Quest," which includes a live update about the Red Planet and how to find it among the stars in the current evening sky.

  5. Insulin-Sensitizing Effects of Omega-3 Fatty Acids: Lost in Translation?

    PubMed Central

    Lalia, Antigoni Z.; Lanza, Ian R.

    2016-01-01

    Omega-3 polyunsaturated fatty acids (n-3 PUFA) of marine origin, eicosapentaenoic acid (EPA), and docosahexaenoic acid (DHA), have been long studied for their therapeutic potential in the context of type 2 diabetes, insulin resistance, and glucose homeostasis. Glaring discordance between observations in animal and human studies precludes, to date, any practical application of n-3 PUFA as nutritional therapeutics against insulin resistance in humans. Our objective in this review is to summarize current knowledge and provide an up-to-date commentary on the therapeutic value of EPA and DHA supplementation for improving insulin sensitivity in humans. We also sought to discuss potential mechanisms of n-3 PUFA action in target tissues, in specific skeletal muscle, based on our recent work, as well as in liver and adipose tissue. We conducted a literature search to include all preclinical and clinical studies performed within the last two years and to comment on representative studies published earlier. Recent studies support a growing consensus that there are beneficial effects of n-3 PUFA on insulin sensitivity in rodents. Observational studies in humans are encouraging, however, the vast majority of human intervention studies fail to demonstrate the benefit of n-3 PUFA in type 2 diabetes or insulin-resistant non-diabetic people. Nevertheless, there are still several unanswered questions regarding the potential impact of n-3 PUFA on metabolic function in humans. PMID:27258299

  6. Delivery of Riboflavin-5'-Monophosphate Into the Cornea: Can Liposomes Provide Any Enhancement Effects?

    PubMed

    Kandzija, Neva; Khutoryanskiy, Vitaliy V

    2017-10-01

    Keratoconus is a progressive condition caused by the thinning of the cornea, which eventually deforms the front surface of the eye into a cone shape leading to ghosting, multiple images, glare, and several other vision problems. Currently, keratoconus is treated with UV-induced riboflavin (Rb)-mediated collagen cross-linking, which requires a physical removal of the corneal epithelium under topical anesthesia. This study reports the penetration of Rb and its more water-soluble form, riboflavin-5'-monophosphate (RbP), into the bovine cornea ex vivo. Using ex vivo bovine corneal tissues and 0.8 mg/mL drug solutions in phosphate buffer, it was established that RbP penetration into the cornea within 3 h of diffusion experiment was greater (17.3 ± 0.8 μg) compared with Rb (10.4 ± 4.2 μg). In the cornea, RbP was found to convert to Rb, which is mediated with enzymes present in this tissue. Several formulations including the conventional and propylene glycol-containing liposomes with encapsulated RbP have been developed, and their effect on the drug penetration into the bovine cornea was evaluated. Encapsulation of RbP into the liposomes did not provide any statistically significant improvement in the penetration of RbP into the cornea. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  7. Social and legal aspects of marriage in women with mental illness in India

    PubMed Central

    Sharma, Indira; Tripathi, C. B.; Pathak, Abhishek

    2015-01-01

    The institution of marriage in Hindus is regulated by the prevailing social norms and the Hindu Marriage Act (HMA), 1955. Married women with mental illness are heavily discriminated. This paper examines the social and legal aspects of Hindu marriage in women with mental illness. The HMA, 1955 lays down the conditions for a Hindu marriage and also provides matrimonial reliefs: Nullity of marriage, restitution of conjugal rights, judicial separation and divorce. The application of the provisions of HMA in the setting mental illness is difficult and challenging. There is a wide gap between the legislative provisions of HMA, and societal value systems and attitudes towards marriage in Indian society. Societal norms are powerful and often override the legal provisions. The disparities are most glaring in the setting of mental illness in women. This is a reflection of social stigma for mental illness and patriarchal attitude towards women. Concerted efforts are needed to bridge the gap between the legislative provisions of HMA and societal value systems and attitudes toward marriage. Awareness programs regarding the nature and types of mental illness, advances in treatment and information about good outcome of severe mental illness will be helpful. Improvement in moral and religious values will overcome to some extent the negative attitudes and patriarchal mind set toward married women with mental illness. PMID:26330650

  8. On the typography of flight-deck documentation

    NASA Technical Reports Server (NTRS)

    Degani, Asaf

    1992-01-01

    Many types of paper documentation are employed on the flight-deck. They range from a simple checklist card to a bulky Aircraft Flight Manual (AFM). Some of these documentations have typographical and graphical deficiencies; yet, many cockpit tasks such as conducting checklists, way-point entry, limitations and performance calculations, and many more, require the use of these documents. Moreover, during emergency and abnormal situations, the flight crews' effectiveness in combating the situation is highly dependent on such documentation; accessing and reading procedures has a significant impact on flight safety. Although flight-deck documentation are an important (and sometimes critical) form of display in the modern cockpit, there is a dearth of information on how to effectively design these displays. The object of this report is to provide a summary of the available literature regarding the design and typographical aspects of printed matter. The report attempts 'to bridge' the gap between basic research about typography, and the kind of information needed by designers of flight-deck documentation. The report focuses on typographical factors such as type-faces, character height, use of lower- and upper-case characters, line length, and spacing. Some graphical aspects such as layout, color coding, fonts, and character contrast are also discussed. In addition, several aspects of cockpit reading conditions such as glare, angular alignment, and paper quality are addressed. Finally, a list of recommendations for the graphical design of flight-deck documentation is provided.

  9. The impact of the luminance, size and location of LED billboards on drivers' visual performance-Laboratory tests.

    PubMed

    Zalesinska, Malgorzata

    2018-08-01

    A proper visual performance by drivers can be ensured by, among else, a correct distribution of luminance in their field of view. At night, when the driver's sight is adapted to low luminance levels, high luminance level objects located near the road may be a source of glare, which is not only a nuisance, but it may also blind the driver. For many years, LED billboards (light-emitting diode billboards) have been installed near roads. Such billboards are usually large, have high luminance and show dynamically changing images. These parameters have a significant impact on the drivers' visual performance and, in turn, on road traffic safety. The study on the impact of the luminance, size and location of LED billboards on the drivers' visual performance was conducted on a volunteer group. Testing the impact of LED billboards on the visual performance of drivers in real-life conditions is very difficult. Therefore, the tests have been conducted in laboratory conditions, using a car driving simulator. The paper describes the testing procedure and tests results. The permissible luminance and areas of LED screens in two locations near the road, which significantly reduce the drivers' visual performance in municipal traffic at night, were determined by conducting an analysis of the results. Recommendations on the permissible luminance and areas of LED billboards were formulated. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Implantation of ArtificialIris, a CustomFlex irisprosthesis, in a trauma patient with an Artisan lens

    PubMed Central

    Doroodgar, Farideh; Jabbarvand, Mahmoud; Niazi, Feizollah; Niazi, Sana; Sanginabadi, Azad

    2017-01-01

    Abstract Purpose: To evaluate probable complications of ArtificialIris implantation with iris fixated intraocular lens. Method: Development of photophobia, glare, and psychological strain during face-to-face communication in a 23-year-old man with a widespread traumatic iris defect terminate to make a decision for performing implantation of an ArtificialIris (Humanoptics, Erlangen, Germany) under the remnant iris without removing the patient's existing Artisan lens. Results: Without any intraoperative or postoperative complications, the patient's visual acuity increased by 1 line, the endothelial cell loss was comparable with the cell loss associated with standard cataract surgery, and the anterior-chamber depth and anterior-chamber anatomy did not change. At the final follow-up examination, the mean intraocular pressure did not differ from baseline, and we achieved high level of patient satisfaction and subjective vision improvement. We discuss the particular importance of considering the patient's expectations, the appropriate measurements, ways to perfect color evaluation, and the types of ArtificialIris products. Conclusion: The implantation of the ArtificialIris in patients with aphakic iris-supported lenses (ie, pre-existing Artisan lenses) is a feasible approach and a useful option for patients with thin irises and iris hypoplasia who are at risk of subluxation or the dislocation of the posterior-chamber intraocular lens (PCIOL), and also those with sclerally fixed PCIOLs. PMID:29137026

  11. Computer modeling of Earthshine contamination on the VIIRS solar diffuser

    NASA Astrophysics Data System (ADS)

    Mills, Stephen P.; Agravante, Hiroshi; Hauss, Bruce; Klein, James E.; Weiss, Stephanie C.

    2005-10-01

    The Visible/Infrared Imager Radiometer Suite (VIIRS), built by Raytheon Santa Barbara Remote Sensing (SBRS) will be one of the primary earth-observing remote-sensing instruments on the National Polar-Orbiting Operational Environmental Satellite System (NPOESS). It will also be installed on the NPOESS Preparatory Project (NPP). These satellite systems fly in near-circular, sun-synchronous low-earth orbits at altitudes of approximately 830 km. VIIRS has 15 bands designed to measure reflectance with wavelengths between 412 nm and 2250 nm, and an additional 7 bands measuring primarily emissive radiance between 3700nm and 11450 nm. The calibration source for the reflective bands is a solar diffuser (SD) that is illuminated once per orbit as the satellite passes from the dark side to the light side of the earth near the poles. Sunlight enters VIIRS through an opening in the front of the instrument. An attenuation screen covers the opening, but other than this there are no other optical elements between the SD and the sun. The BRDF of the SD and the transmittance of the attenuation screen is measured pre-flight, and so with knowledge of the angles of incidence, the radiance of the sun can be computed and is used as a reference to produce calibrated reflectances and radiances. Unfortunately, the opening also allows a significant amount of reflected earthshine to illuminate part of the SD, and this component introduces radiometric error to the calibration process, referred to as earthshine contamination (ESC). The VIIRS radiometric error budget allocated a 0.3% error based on modeling of the ESC done by SBRS during the design phase. This model assumes that the earth has Lambertian BRDF with a maximum top-of-atmosphere albedo of 1. The Moderate Resolution Imaging Spectroradiometer (MODIS) has an SD with a design similar to VIIRS, and in 2003 the MODIS Science Team reported to Northrop Grumman Space Technology (NGST), the prime contractor for NPOESS, their suspicion that ESC was causing higher than expected radiometric error, and asked whether VIIRS might have a similar problem. The NPOESS Models and Simulation (M&S) team considered whether the Lambertian BRDF assumption would cause an underestimating of the ESC error. Particularly, snow, ice and water show very large BRDFs for geometries for forward scattered, near-grazing angles of incidence, and in common parlance this is called glare. The observed earth geometry during the period where the SD is illuminated by the sun has just such geometries that produce strongly forward scattering glare. In addition the SD acquisition occurs in the polar regions, where snow, ice and water are most prevalent. Using models in their Environmental Products Verification and Remote Sensing Testbed (EVEREST), the M&S team produced a model that meticulously traced the light rays from the attenuation screen to each detector and combined this with a model of the satellite orbit, with solar geometry and radiative transfer models that include the effect of the BRDF of various surfaces. This modeling showed that radiometric errors up to 4.5% over water and 1.5% over snow or ice. Clouds produce errors up to 0.8%. The likelihood of these high errors occurring has not been determined. Because of this analysis, various remedial options are now being considered.

  12. Edge-on!

    NASA Astrophysics Data System (ADS)

    2007-08-01

    Peering at Uranus's Rings as they Swing Edge-on to Earth for the First Time Since their Discovery in 1977 As Uranus coasts through a brief window of time when its rings are edge-on to Earth - a view of the planet we get only once every 42 years - astronomers peering at the rings with ESO's Very Large Telescope and other space or ground-based telescopes are getting an unprecedented view of the fine dust in the system, free from the glare of the bright rocky rings. They may even find a new moon or two. ESO PR Photo 37/07 ESO PR Photo 37/07 The Uranus System "ESO's VLT took data at the precise moment when the rings were edge-on to Earth," said Imke de Pater, of University of California, Berkeley who coordinated the worldwide campaign. She worked with two team members observing in Chile: Daphne Stam of the Technical University Delft in the Netherlands and Markus Hartung of ESO. The observations were done with NACO, one of the adaptive optics instruments installed at the VLT. With adaptive optics, it is possible to obtain images almost free from the blurring effect of the atmosphere. It is as if the 8.2-m telescope were observing from space. Observations were also done with the Keck telescope in Hawaii, the Hubble Space Telescope, and at the Palomar Observatory. "Using different telescopes around the world allows us to observe as much of the changes during the ring-plane crossing as possible: when Uranus sets as seen from the VLT, it can still be observed by the Keck," emphasised Stam. Uranus orbits the Sun in 84 years. Twice during a Uranian year, the rings appear edge-on to Earth for a brief period. The rings were discovered in 1977, so this is the first time for a Uranus ring-crossing to be observed from Earth. The advantage of observations at a ring-plane crossing is that it becomes possible to look at the rings from the shadowed or dark side. From that vantage point, the normally bright outer rings grow fainter because their centimetre- to metre-sized rocks obscure one another, while the dim inner rings get brighter as their material merges into a thin band along the line of sight. Two little satellites called Cordelia and Ophelia straddle the brightest ring, the 'Epsilon Ring', and keep it in place, but it has always been assumed there must be more of these satellites that are confining the 9 other narrow rings. Normally the satellites are lost in the glare of the rings, but during these events the unique orientation makes the bright rings essentially invisible. Thus the ring plane crossing gives astronomers a rare chance, just once every 42 years, to image these tiny satellites. Imke de Pater and colleagues made observations of the rings with the Keck II telescope on 28 May 2007. These observations are presented in an article appearing today (Thursday 23 August) in Science Express, the online edition of Science magazine. There, the astronomers report that the rings of micron-sized dust have changed significantly since the Voyager 2 spacecraft photographed the Uranus system 21 years ago. Imke de Pater will discuss these results and the new images during a talk today at the European Planetary Science Congress 2007 meeting in Potsdam, Germany. An image of Uranus with the rings clearly visible was taken with ISAAC on ESO's VLT in 2002. It is available in ESO Press Photo 31/02.

  13. Randomized, double-blind, placebo-controlled study of zeaxanthin and visual function in patients with atrophic age-related macular degeneration: the Zeaxanthin and Visual Function Study (ZVF) FDA IND #78, 973.

    PubMed

    Richer, Stuart P; Stiles, William; Graham-Hoffman, Kelly; Levin, Marc; Ruskin, Dennis; Wrobel, James; Park, Dong-Wouk; Thomas, Carla

    2011-11-01

    The purpose of this study is to evaluate whether dietary supplementation with the carotenoid zeaxanthin (Zx) raises macula pigment optical density (MPOD) and has unique visual benefits for patients with early atrophic macular degeneration having visual symptoms but lower-risk National Institute of Health/National Eye Institute/Age-Related Eye Disease Study characteristics. This was a 1-year, n = 60 (57 men, 3 women), 4-visit, intention-to-treat, prospective, randomized controlled clinical trial of patients (74.9 years, standard deviation [SD] 10) with mild-to-moderate age-related macular degeneration (AMD) randomly assigned to 1 of 2 dietary supplement carotenoid pigment intervention groups: 8 mg Zx (n = 25) and 8 mg Zx plus 9 mg lutein (L) (n = 25) or 9 mg L ("Faux Placebo," control group, n = 10). Analysis was by Bartlett's test for equal variance, 3-way repeated factors analysis of variance, independent t test (P < 0.05) for variance and between/within group differences, and post-hoc Scheffé's tests. Estimated foveal heterochromic flicker photometry, 1° macular pigment optical density (MPOD QuantifEye(®)), low- and high-contrast visual acuity, foveal shape discrimination (Retina Foundation of the Southwest), 10° yellow kinetic visual fields (KVF), glare recovery, contrast sensitivity function (CSF), and 6° blue cone ChromaTest(®) color thresholds were obtained serially at 4, 8, and 12 months. Ninety percent of subjects completed ≥ 2 visits with an initial Age-Related Eye Disease Study report #18 retinopathy score of 1.4 (1.0 SD)/4.0 and pill intake compliance of 96% with no adverse effects. There were no intergroup differences in 3 major AMD risk factors: age, smoking, and body mass index as well as disease duration and Visual Function Questionnaire 25 composite score differences. Randomization resulted in equal MPOD variance and MPOD increasing in each of the 3 groups from 0.33 density units (du) (0.17 SD) baseline to 0.51 du (0.18 SD) at 12 m, (P = 0.03), but no between-group differences (Analysis of Variance; P = 0.47). In the Zx group, detailed high-contrast visual acuity improved by 1.5 lines, Retina Foundation of the Southwest shape discrimination sharpened from 0.97 to 0.57 (P = 0.06, 1-tail), and a larger percentage of Zx patients experienced clearing of their KVF central scotomas (P = 0.057). The "Faux Placebo" L group was superior in terms of low-contrast visual acuity, CSF, and glare recovery, whereas Zx showed a trend toward significance. In older male patients with AMD, Zx-induced foveal MPOD elevation mirrored that of L and provided complementary distinct visual benefits by improving foveal cone-based visual parameters, whereas L enhanced those parameters associated with gross detailed rod-based vision, with considerable overlap between the 2 carotenoids. The equally dosed (atypical dietary ratio) Zx plus L group fared worse in terms of raising MPOD, presumably because of duodenal, hepatic-lipoprotein or retinal carotenoid competition. These results make biological sense based on retinal distribution and Zx foveal predominance. Published by Elsevier Inc.

  14. Assessment of the Psychometric Properties of a Questionnaire Assessing Patient-Reported Outcomes With Laser In Situ Keratomileusis (PROWL).

    PubMed

    Hays, Ron D; Tarver, Michelle E; Spritzer, Karen L; Reise, Steve; Hilmantel, Gene; Hofmeister, Elizabeth M; Hammel, Keri; May, Jeanine; Ferris, Frederick; Eydelman, Malvina

    2017-01-01

    Patient-reported outcome (PRO) measures for laser in situ keratomileusis (LASIK) are needed. To develop PRO measures to assess satisfaction, eye-related symptoms, and their effect on functioning and well-being following LASIK based on patient and expert input. The Patient-Reported Outcomes With LASIK (PROWL) studies were prospective observational studies of patients undergoing LASIK surgery for myopia, hyperopia, or astigmatism. PROWL-1 was a single-center study of active-duty US Navy personnel and PROWL-2 was a 5-center study of civilians. PROWL-1 enrolled 262 active-duty service personnel and PROWL-2 enrolled 312 civilians 21 years or older who spoke English; 241 individuals in PROWL-1 and 280 in PROWL-2 completed a baseline questionnaire before surgery. The analytic sample included those also completing 1 or more follow-up questionnaires: 240 (99.6%) of those in PROWL-1 and 271 (94.4%) of those in PROWL-2. Questionnaires were self-administered through the internet preoperatively and at 1 and 3 months postoperatively in both studies and at 6 months postoperatively in PROWL-1. PROWL-1 began in August 2011 and was completed May 30, 2014; PROWL-2 began in July 2012 and was completed June 27, 2014. Data were analyzed from June 28, 2014, to October 24, 2016. Scales assessing visual symptoms (double images, glare, halos, and starbursts), dry eye symptoms, satisfaction with vision, and satisfaction with LASIK surgery. Items from the National Eye Institute (NEI) Refractive Error Quality of Life Instrument (NEI-RQL-42), NEI Visual Function Questionnaire (NEI-VFQ), and the Ocular Surface Disease Index (OSDI) were included. All scales are scored on a 0 to 100 possible range. Construct validity and responsiveness to change were evaluated (comparing scores before and after surgery). The median age of the 240-person PROWL-1 analytic sample was 27 years (range, 21-52 years); 49 were women (20.4%). The median age of the 271-person PROWL-2 analytic sample was 30 years (range, 21-57 years); 147 were women (54.2%). Internal consistency reliabilities for the 4 visual symptom scales ranged from 0.96 to 0.98 in PROWL-1 and from 0.95 to 0.97 in PROWL-2. The median (interquartile range) test-retest intraclass correlation was 0.69 (0.57-0.79) and 0.76 (0.68-0.84) in PROWL-1 and PROWL-2, respectively. Product-moment correlations of satisfaction with surgery with visual symptom scales at follow-up evaluations ranged from r = 0.24 to r = 0.49. Measures improved from baseline to follow-up, with effect sizes of 0.14 to 1.98, but scores on the NEI-RQL-42 glare scale worsened at the 1-month follow-up. Hours of work did not change significantly from baseline to 1-month follow-up, with the mean number (mean [SD] difference) in PROWL-1 of 41.7 vs 40.9 hours (-0.8 [18.7]) and in PROWL-2 of 38.8 vs 38.2 hours (-0.6 [17.1]). The results of these studies support the reliability and validity of visual symptom scales to evaluate the effects of LASIK surgery in future studies.

  15. Disturbance of visual functions as a result of temporary blinding from low power lasers

    NASA Astrophysics Data System (ADS)

    Reidenbach, Hans-Dieter

    2010-04-01

    Although it is well-known that dazzle, flash-blindness and afterimages may be caused by bright optical radiation, only sparse quantitative data are available with regard to the effects arising from low power laser products. Indirect effects like temporary blinding might result in serious incidents or even accidents due to the alteration of visual functions like visual acuity, contrast sensitivity and color discrimination. In order to determine the degree and duration of impairment resulting from dazzle, flash-blindness and afterimages, caused by a laser beam, an investigation has been performed with the goal to improve the current knowledge as far as especially the visual acuity recovery duration is concerned. Two different test set-ups were designed and applied in order to determine the afterimage duration and the recovery time for visual acuity after temporary blinding from a laser, respectively. In order to get the desired information a helium-neon laser was mounted on a movable assembly where the respective beam position and direction could be set up on a semicircle. In addition the mount could be inclined in a vertical plane in order to increase the variability of feasible settings. The power was adjusted in several steps in order to investigate the respective dependence of the afterimage. The investigations were relatively time consuming, since re-adaptation of about half an hour was necessary after every exposure in order not to falsify the results. The trials have been done with several volunteers in the laboratory. After the experimental mapping of the local afterimage duration for the various sites on the retina the foveal afterimage duration taf,fv produced by a red laser beam was determined. The investigations have shown a strong dependence on the angle between the line of sight and the beam direction. Besides a maximum of 300 s the dose relationship taf,fv/s ~ 50.6•ln[(P•texp)/μJ] - 13.4 for laser output powers P between 10 μW and 30 μW with exposure durations texp from 0.25 s up to 10 s was found. The inability to read due to the disturbance produced by afterimages lasts for about 20 s even if the exposure is not more than 0.25 s from a laser with about 0.8 mW optical output power. In addition to the physiological effects of temporary blinding the psychological glare was determined as a function of the angle between line of sight and beam direction. It was found that already at output powers below 30 μW of a He-Nelaser the subjects reported intense glare effects and felt uncomfortable due to the high brightness. Instead of the standard visual acuity measurement used by eye care professionals, a reading test on a computer monitor was applied after laser irradiation. In this case two different lasers were used as a dazzling light source, one with a wavelength of 632.8 nm and the other with 532 nm. The maximum applied optical power in a 7-mm aperture, which is equivalent to the pupil diameter of a dark adapted eye, was 0.783 mW. The exposure durations were chosen as 0.25 s, 0.5 s, 1 s, 5 s, and 20 s.

  16. Contact lens wear by Royal Air Force aircrew in World War II.

    PubMed

    Pearson, Richard M

    2014-04-01

    To provide an overview of the use of contact lenses by RAF aircrew in World War II by identifying some of the fitters and wearers and appraising the clinical results that they achieved. A wide-ranging literature search was undertaken that encompassed peer-reviewed journals, non-refereed publications, books, official publications, newspapers and archived documents. Thirty-one aircrew are known to have worn sealed scleral lenses in order to meet the required visual standards. Of these, only two were considered to be completely unsuccessful, one of whom was unilaterally aphakic. One additional case of undisclosed contact lens wear was found and the identity of this officer was established. Brief biographies of a few pilots establish the context of their contact lens wear. Overall, the results of scleral lens wear were variable reflecting those achieved by civilian patients of the period. While three men complained of discomfort due to heat and glare, one pilot experienced no photophobia when flying above white clouds in brilliant sunshine and another found no difficulty caused by altitude or tropical climate. Wearing time ranged from about 2h to 16, or more, hours. In about a third of the cases, wearing time was limited due to the onset of a form of contact lens induced-epithelial oedema known as Sattler's veil and effective solutions to this problem were not implemented until after the war. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  17. The psychiatric interview: validity, structure, and subjectivity.

    PubMed

    Nordgaard, Julie; Sass, Louis A; Parnas, Josef

    2013-06-01

    There is a glaring gap in the psychiatric literature concerning the nature of psychiatric symptoms and signs, and a corresponding lack of epistemological discussion of psycho-diagnostic interviewing. Contemporary clinical neuroscience heavily relies on the use of fully structured interviews that are historically rooted in logical positivism and behaviorism. These theoretical approaches marked decisively the so-called "operational revolution in psychiatry" leading to the creation of DSM-III. This paper attempts to examine the theoretical assumptions that underlie the use of a fully structured psychiatric interview. We address the ontological status of pathological experience, the notions of symptom, sign, prototype and Gestalt, and the necessary second-person processes which are involved in converting the patient's experience (originally lived in the first-person perspective) into an "objective" (third person), actionable format, used for classification, treatment, and research. Our central thesis is that psychiatry targets the phenomena of consciousness, which, unlike somatic symptoms and signs, cannot be grasped on the analogy with material thing-like objects. We claim that in order to perform faithful distinctions in this particular domain, we need a more adequate approach, that is, an approach that is guided by phenomenologically informed considerations. Our theoretical discussion draws upon clinical examples derived from structured and semi-structured interviews. We conclude that fully structured interview is neither theoretically adequate nor practically valid in obtaining psycho-diagnostic information. Failure to address these basic issues may have contributed to the current state of malaise in the study of psychopathology.

  18. Project Blue: Optical Coronagraphic Imaging Search for Terrestrial-class Exoplanets in Alpha Centauri

    NASA Astrophysics Data System (ADS)

    Morse, Jon; Project Blue team

    2018-01-01

    Project Blue is a coronagraphic imaging space telescope mission designed to search for habitable worlds orbiting the nearest Sun-like stars in the Alpha Centauri system. With a 45-50 cm baseline primary mirror size, Project Blue will perform a reconnaissance of the habitable zones of Alpha Centauri A and B in blue light and one or two longer wavelength bands to determine the hue of any planets discovered. Light passing through the off-axis telescope feeds into a coronagraphic instrument that forms the heart of the mission. Various coronagraph designs are being considered, such as phase induced amplitude apodization (PIAA), vector vortex, etc. Differential orbital image processing techniques will be employed to analyze the data for faint planets embedded in the residual glare of the parent star. Project Blue will advance our knowledge about the presence or absence of terrestrial-class exoplanets in the habitable zones and measure the brightness of zodiacal dust around each star, which will aid future missions in planning their observational surveys of exoplanets. It also provides on-orbit demonstration of high-contrast coronagraphic imaging technologies and techniques that will be useful for planning and implementing future space missions by NASA and other space agencies. We present an overview of the science goals, mission concept and development schedule. As part of our cooperative agreement with NASA, the Project Blue team intends to make the data available in a publicly accessible archive.

  19. Integrating daylighting into a 3,000 seat church auditorium and network quality television production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holder, L.M. III; Holder, L.M. IV

    1999-07-01

    The project was designed by the Overland Partners Architectural Firm for Riverbend Church of Austin as an Auditorium for Sunday Services and a venue for special theatrical presentations for the church and the community as well. It is an amphitheater on a hillside overlooking the Colorado River Valley. The amphitheater was selected as the building form to keep the audience closer to the speaker. A 175 ft wide by 60 ft tall arched window was installed on the north face to allow the audience to see the panorama views of the tree covered hills on the other side of themore » valley in the Texas Hill Country. Although the design is quite effective in achieving the program goals, these characteristics make it difficult to achieve effective daylighting without glare for the audience and television cameras since both face the north glazing. The design team was faced with providing quality daylighting for the audience and television cameras from the wall behind the stage. Most television studios have carefully controlled lighting systems with the major lighting component from behind the cameras. Virtually all television facilities with daylight contributing to the production lighting are in a building with high shading coefficient glass producing illumination on all areas equally or almost all glass and daylighting from skylights and clearstories above. All television networks have requirements for control of the quality of the video images to parallel those conditions for the program to be aired.« less

  20. DISCOVERY OF A MAKEMAKEAN MOON

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Alex H.; Buie, Marc W.; Grundy, Will M.

    We describe the discovery of a satellite in orbit about the dwarf planet (136472) Makemake. This satellite, provisionally designated S/2015 (136472) 1, was detected in imaging data collected with the Hubble Space Telescope ’s Wide Field Camera 3 on UTC 2015 April 27 at 7.80 ± 0.04 mag fainter than Makemake and at a separation of 0.″57. It likely evaded detection in previous satellite searches due to a nearly edge-on orbital configuration, placing it deep within the glare of Makemake during a substantial fraction of its orbital period. This configuration would place Makemake and its satellite near a mutual eventmore » season. Insufficient orbital motion was detected to make a detailed characterization of its orbital properties, prohibiting a measurement of the system mass with the discovery data alone. Preliminary analysis indicates that if the orbit is circular, its orbital period must be longer than 12.4 days and must have a semimajor axis ≳21,000 km. We find that the properties of Makemake’s moon suggest that the majority of the dark material detected in the system by thermal observations may not reside on the surface of Makemake, but may instead be attributable to S/2015 (136472) 1 having a uniform dark surface. This “dark moon hypothesis” can be directly tested with future James Webb Space Telescope observations. We discuss the implications of this discovery for the spin state, figure, and thermal properties of Makemake and the apparent ubiquity of trans-Neptunian dwarf planet satellites.« less

Top