Longitudinal and Circumferential Strain of the Proximal Aorta
Bell, Vanessa; Mitchell, William A.; Sigurðsson, Sigurður; Westenberg, Jos J. M.; Gotal, John D.; Torjesen, Alyssa A.; Aspelund, Thor; Launer, Lenore J.; de Roos, Albert; Gudnason, Vilmundur; Harris, Tamara B.; Mitchell, Gary F.
2014-01-01
Background Accurate assessment of mechanical properties of the proximal aorta is a requisite first step for elucidating the pathophysiology of isolated systolic hypertension. During systole, substantial proximal aortic axial displacement produces longitudinal strain, which we hypothesize causes variable underestimation of ascending aortic circumferential strain compared to values in the longitudinally constrained descending aorta. Methods and Results To assess effects of longitudinal strain, we performed magnetic resonance imaging in 375 participants (72 to 94 years old, 204 women) in the Age, Gene/Environment Susceptibility‐Reykjavik Study and measured aortic circumferential and longitudinal strain. Circumferential ascending aortic area strain uncorrected for longitudinal strain was comparable in women and men (mean [95% CI], 8.3 [7.8, 8.9] versus 7.9 [7.4, 8.5]%, respectively, P=0.3). However, longitudinal strain was greater in women (8.5±2.5 versus 7.0±2.5%, P<0.001), resulting in greater longitudinally corrected circumferential ascending aortic strain (14.4 [13.6, 15.2] versus 13.0 [12.4, 13.7]%, P=0.010). Observed circumferential descending aortic strain, which did not require correction (women: 14.0 [13.2, 14.8], men: 12.4 [11.6, 13.2]%, P=0.005), was larger than uncorrected (P<0.001), but comparable to longitudinally corrected (P=0.12) circumferential ascending aortic strain. Carotid‐femoral pulse wave velocity did not correlate with uncorrected ascending aortic strain (R=−0.04, P=0.5), but was inversely related to longitudinally corrected ascending and observed descending aortic strain (R=−0.15, P=0.004; R=−0.36, P<0.001, respectively). Longitudinal strain was also inversely related to carotid‐femoral pulse wave velocity and other risk factors for higher aortic stiffness including treated hypertension. Conclusions Longitudinal strain creates substantial and variable errors in circumferential ascending aortic area strain measurements
Segmental Analysis of Cardiac Short-Axis Views Using Lagrangian Radial and Circumferential Strain.
Ma, Chi; Wang, Xiao; Varghese, Tomy
2016-11-01
Accurate description of myocardial deformation in the left ventricle is a three-dimensional problem, requiring three normal strain components along its natural axis, that is, longitudinal, radial, and circumferential strains. Although longitudinal strains are best estimated from long-axis views, radial and circumferential strains are best depicted in short-axis views. An algorithm that utilizes a polar grid for short-axis views previously developed in our laboratory for a Lagrangian description of tissue deformation is utilized for radial and circumferential displacement and strain estimation. Deformation of the myocardial wall, utilizing numerical simulations with ANSYS, and a finite-element analysis-based canine heart model were adapted as the input to a frequency-domain ultrasound simulation program to generate radiofrequency echo signals. Clinical in vivo data were also acquired from a healthy volunteer. Local displacements estimated along and perpendicular to the ultrasound beam propagation direction are then transformed into radial and circumferential displacements and strains using the polar grid based on a pre-determined centroid location. Lagrangian strain variations demonstrate good agreement with the ideal strain when compared with Eulerian results. Lagrangian radial and circumferential strain estimation results are also demonstrated for experimental data on a healthy volunteer. Lagrangian radial and circumferential strain tracking provide accurate results with the assistance of the polar grid, as demonstrated using both numerical simulations and in vivo study. © The Author(s) 2015.
Segmental Analysis of Cardiac Short-Axis Views Using Lagrangian Radial and Circumferential Strain
Ma, Chi; Wang, Xiao; Varghese, Tomy
2016-01-01
Accurate description of myocardial deformation in the left ventricle is a three-dimensional problem, requiring three normal strain components along its natural axis, that is, longitudinal, radial, and circumferential strains. Although longitudinal strains are best estimated from long-axis views, radial and circumferential strains are best depicted in short-axis views. An algorithm that utilizes a polar grid for short-axis views previously developed in our laboratory for a Lagrangian description of tissue deformation is utilized for radial and circumferential displacement and strain estimation. Deformation of the myocardial wall, utilizing numerical simulations with ANSYS, and a finite-element analysis–based canine heart model were adapted as the input to a frequency-domain ultrasound simulation program to generate radiofrequency echo signals. Clinical in vivo data were also acquired from a healthy volunteer. Local displacements estimated along and perpendicular to the ultrasound beam propagation direction are then transformed into radial and circumferential displacements and strains using the polar grid based on a pre-determined centroid location. Lagrangian strain variations demonstrate good agreement with the ideal strain when compared with Eulerian results. Lagrangian radial and circumferential strain estimation results are also demonstrated for experimental data on a healthy volunteer. Lagrangian radial and circumferential strain tracking provide accurate results with the assistance of the polar grid, as demonstrated using both numerical simulations and in vivo study. PMID:26578642
Wan, Jinjin; He, Fangli; Zhao, Yongfeng; Zhang, Hongmei; Zhou, Xiaodong; Wan, Mingxi
2014-03-01
The aim of this work was to develop a convenient method for radial/circumferential strain imaging and shear rate estimation that could be used as a supplement to the current routine screening for carotid atherosclerosis using video images of diagnostic ultrasound. A reflection model-based correction for gray-scale non-uniform distribution was applied to B-mode video images before strain estimation to improve the accuracy of radial/circumferential strain imaging when applied to vessel transverse cross sections. The incremental and cumulative radial/circumferential strain images can then be calculated based on the displacement field between consecutive B-mode images. Finally, the transverse Doppler spectra acquired at different depths along the vessel diameter were used to construct the spatially matched instantaneous wall shear values in a cardiac cycle. Vessel phantom simulation results revealed that the signal-to-noise ratio and contrast-to-noise ratio of the radial and circumferential strain images were increased by 2.8 and 5.9 dB and by 2.3 and 4.4 dB, respectively, after non-uniform correction. Preliminary results for 17 patients indicated that the accuracy of radial/circumferential strain images was improved in the lateral direction after non-uniform correction. The peak-to-peak value of incremental strain and the maximum cumulative strain for calcified plaques are evidently lower than those for other plaque types, and the echolucent plaques had higher values, on average, than the mixed plaques. Moreover, low oscillating wall shear rate values, found near the plaque and stenosis regions, are closely related to plaque formation. In conclusion, the method described can provide additional valuable results as a supplement to the current routine ultrasound examination for carotid atherosclerosis and, therefore, has significant potential as a feasible screening method for atherosclerosis diagnosis in the future. Copyright © 2014 World Federation for Ultrasound in
Fekkes, Stein; Swillens, Abigail E S; Hansen, Hendrik H G; Saris, Anne E C M; Nillesen, Maartje M; Iannaccone, Francesco; Segers, Patrick; de Korte, Chris L
2016-10-01
Three-dimensional (3-D) strain estimation might improve the detection and localization of high strain regions in the carotid artery (CA) for identification of vulnerable plaques. This paper compares 2-D versus 3-D displacement estimation in terms of radial and circumferential strain using simulated ultrasound (US) images of a patient-specific 3-D atherosclerotic CA model at the bifurcation embedded in surrounding tissue generated with ABAQUS software. Global longitudinal motion was superimposed to the model based on the literature data. A Philips L11-3 linear array transducer was simulated, which transmitted plane waves at three alternating angles at a pulse repetition rate of 10 kHz. Interframe (IF) radio-frequency US data were simulated in Field II for 191 equally spaced longitudinal positions of the internal CA. Accumulated radial and circumferential displacements were estimated using tracking of the IF displacements estimated by a two-step normalized cross-correlation method and displacement compounding. Least-squares strain estimation was performed to determine accumulated radial and circumferential strain. The performance of the 2-D and 3-D methods was compared by calculating the root-mean-squared error of the estimated strains with respect to the reference strains obtained from the model. More accurate strain images were obtained using the 3-D displacement estimation for the entire cardiac cycle. The 3-D technique clearly outperformed the 2-D technique in phases with high IF longitudinal motion. In fact, the large IF longitudinal motion rendered it impossible to accurately track the tissue and cumulate strains over the entire cardiac cycle with the 2-D technique.
Hwang, In-Chang; Cho, Goo-Yeong; Yoon, Yeonyee E; Park, Jin Joo
2018-01-01
The prognostic value of left ventricular (LV) global strain and twist in patients with left bundle branch block (LBBB) is not fully investigated. The aim of this study was to investigate the association between myocardial strain and twist and cardiovascular events in patients with LBBB, as assessed using two-dimensional speckle-tracking echocardiography. A total of 269 patients with LBBB (mean age, 69.5 ± 10.9 years; 46.8% men) were retrospectively identified. Using speckle-tracking, LV global longitudinal strain (GLS), global circumferential strain, and twist were measured. Association between LV global function and a composite of cardiovascular mortality and hospitalization for heart failure was compared with clinical risk factors, LV ejection fraction (LVEF), and other echocardiographic parameters. During a median of 27.5 months (interquartile range, 12.8-43.9 months), the composite end point occurred in 55 patients (20.4%). In univariate analyses, diabetes mellitus, chronic kidney disease, ischemic etiology of LBBB, dilated left atrium, reduced LVEF, dilated left ventricle, and impaired LV global strain (GLS > -12.2%, global circumferential strain > -11.8%, and twist < 6.5°) showed associations with the composite end point. In multivariate analyses, GLS was significantly associated with the composite end point (adjusted hazard ratio, 4.697; 95% CI, 1.344-16.413; P = .015), whereas global circumferential strain, twist, and LVEF were not. GLS showed an additive association with poor prognosis over clinical risk factors and other echocardiographic parameters, including LVEF. Patients with preserved LVEFs (≥40%) but impaired GLS (>-12.2%) had a larger number of clinical events than those with impaired LVEFs but preserved GLS. Among patients with LBBB, GLS can provide better risk stratification than LVEF or other echocardiographic parameters. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Larsson, Matilda; Heyde, Brecht; Kremer, Florence; Brodin, Lars-Åke; D'hooge, Jan
2015-02-01
Ultrasound speckle tracking for carotid strain assessment has in the past decade gained interest in studies of arterial stiffness and cardiovascular diseases. The aim of this study was to validate and directly contrast carotid strain assessment by speckle tracking applied on clinical and high-frequency ultrasound images in vitro. Four polyvinyl alcohol phantoms mimicking the carotid artery were constructed with different mechanical properties and connected to a pump generating carotid flow profiles. Gray-scale ultrasound long- and short-axis images of the phantoms were obtained using a standard clinical ultrasound system, Vivid 7 (GE Healthcare, Horten, Norway) and a high-frequency ultrasound system, Vevo 2100 (FUJIFILM, VisualSonics, Toronto, Canada) with linear-array transducers (12L/MS250). Radial, longitudinal and circumferential strains were estimated using an in-house speckle tracking algorithm and compared with reference strain acquired by sonomicrometry. Overall, the estimated strain corresponded well with the reference strain. The correlation between estimated peak strain in clinical ultrasound images and reference strain was 0.91 (p<0.001) for radial strain, 0.73 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain and for high-frequency ultrasound images 0.95 (p<0.001) for radial strain, 0.93 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain. A significant larger bias and root mean square error was found for circumferential strain estimation on clinical ultrasound images compared to high frequency ultrasound images, but no significant difference in bias and root mean square error was found for radial and longitudinal strain when comparing estimation on clinical and high-frequency ultrasound images. The agreement between sonomicrometry and speckle tracking demonstrates that carotid strain assessment by ultrasound speckle tracking is feasible. Copyright © 2014 The Authors. Published by Elsevier B
Murai, Daisuke; Yamada, Satoshi; Hayashi, Taichi; Okada, Kazunori; Nishino, Hisao; Nakabachi, Masahiro; Yokoyama, Shinobu; Abe, Ayumu; Ichikawa, Ayako; Ono, Kota; Kaga, Sanae; Iwano, Hiroyuki; Mikami, Taisei; Tsutsui, Hiroyuki
2017-05-01
Whether and how left ventricular (LV) strain and strain rate correlate with wall stress is not known. Furthermore, it is not determined whether strain or strain rate is less dependent on the afterload. In 41 healthy young adults, LV global peak strain and systolic peak strain rate in the longitudinal direction (LS and LSR, respectively) and circumferential direction (CS and CSR, respectively) were measured layer-specifically using speckle tracking echocardiography (STE) before and during a handgrip exercise. Among all the points before and during the exercise, all the STE parameters significantly correlated linearly with wall stress (LS: r = -0.53, p < 0.01, LSR: r = -0.28, p < 0.05, CS in the inner layer: r = -0.72, p < 0.01, CSR in the inner layer: r = -0.47, p < 0.01). Strain more strongly correlated with wall stress than strain rate (r = -0.53 for LS vs. r = -0.28 for LSR, p < 0.05; r = -0.72 for CS vs. r = -0.47 for CSR in the inner layer, p < 0.05), whereas the interobserver variability was similar between strain and strain rate (longitudinal 6.2 vs. 5.2 %, inner circumferential 4.8 vs. 4.7 %, mid-circumferential 7.9 vs. 6.9 %, outer circumferential 10.4 vs. 9.7 %), indicating that the differences in correlation coefficients reflect those in afterload dependency. It was thus concluded that LV strain and strain rate linearly and inversely correlated with wall stress in the longitudinal and circumferential directions, and strain more strongly depended on afterload than did strain rate. Myocardial shortening should be evaluated based on the relationships between these parameters and wall stress.
Wang, Liang; Zhu, Jian; Samady, Habib; Monoly, David; Zheng, Jie; Guo, Xiaoya; Maehara, Akiko; Yang, Chun; Ma, Genshan; Mintz, Gary S.; Tang, Dalin
2017-01-01
Accurate stress and strain calculations are important for plaque progression and vulnerability assessment. Models based on in vivo data often need to form geometries with zero-stress/strain conditions. The goal of this paper is to use IVUS-based near-idealized geometries and introduce a three-step model construction process to include residual stress, axial shrinkage, and circumferential shrinkage and investigate their impacts on stress and strain calculations. In Vivo intravascular ultrasound (IVUS) data of human coronary were acquired for model construction. In Vivo IVUS movie data were acquired and used to determine patient-specific material parameter values. A three-step modeling procedure was used to make our model: (a) wrap the zero-stress vessel sector to obtain the residual stress; (b) stretch the vessel axially to its length in vivo; and (c) pressurize the vessel to recover its in vivo geometry. Eight models were constructed for our investigation. Wrapping led to reduced lumen and cap stress and increased out boundary stress. The model with axial stretch, circumferential shrink, but no wrapping overestimated lumen and cap stress by 182% and 448%, respectively. The model with wrapping, circumferential shrink, but no axial stretch predicted average lumen stress and cap stress as 0.76 kPa and −15 kPa. The same model with 10% axial stretch had 42.53 kPa lumen stress and 29.0 kPa cap stress, respectively. Skipping circumferential shrinkage leads to overexpansion of the vessel and incorrect stress/strain calculations. Vessel stiffness increase (100%) leads to 75% lumen stress increase and 102% cap stress increase. PMID:27814429
Mangion, Kenneth; Clerfond, Guillaume; McComb, Christie; Carrick, David; Rauhalammi, Samuli M; McClure, John; Corcoran, David S; Woodward, Rosemary; Orchard, Vanessa; Radjenovic, Aleksandra; Zhong, Xiaodong; Berry, Colin
2016-11-01
To assess myocardial strain using cine displacement encoding with stimulated echoes (DENSE) using 1.5T and 3.0T MRI in healthy adults. Healthy adults without any history of cardiovascular disease underwent magnetic resonance imaging (MRI) at 1.5T and 3.0T within 2 days. The MRI protocol included balanced steady-state free-precession (b-SSFP), 2D cine-echo planar imaging (EPI)-DENSE, and late gadolinium enhancement in subjects >45 years. Acquisitions were divided into six segments; global and segmental peak longitudinal and circumferential strain were derived and analyzed by field strength, age, and gender. In all, 89 volunteers (mean age 44.8 ± 18.0 years, range: 18-87 years) underwent MRI at 1.5T, and 88 of these subjects underwent MRI at 3.0T (1.4 ± 1.4 days between the scans). Compared with 3.0T, the magnitudes of global circumferential (-19.5 ± 2.6% vs. -18.47 ± 2.6%; P = 0.001) and longitudinal (-12.47 ± 3.2% vs. -10.53 ± 3.1%; P = 0.004) strain were greater at 1.5T. At 1.5T, longitudinal strain was greater in females than in males: -10.17 ± 3.4% vs. -13.67 ± 2.4%; P = 0.001. Similar observations occurred for circumferential strain at 1.5T (-18.72 ± 2.2% vs. -20.10 ± 2.7%; P = 0.014) and at 3.0T (-17.92 ± 1.8% vs. -19.1 ± 3.1%; P = 0.047). At 1.5T, longitudinal and circumferential strain were not associated with age after accounting for sex (longitudinal strain P = 0.178, circumferential strain P = 0.733). At 3.0T, longitudinal and circumferential strain were associated with age (P < 0.05). Longitudinal strain values were greater in the apico-septal, basal-lateral, and mid-lateral segments and circumferential strain in the inferior, infero-lateral, and antero-lateral LV segments. Myocardial strain parameters as revealed by cine-DENSE at different MRI field strengths were associated with myocardial region, age, and sex. J. Magn. Reson. Imaging 2016;44:1197-1205. © 2016 The Authors Journal of Magnetic Resonance Imaging published by Wiley Periodicals
Prati, Giulio; Vitrella, Giancarlo; Allocca, Giuseppe; Muser, Daniele; Buttignoni, Sonja Cukon; Piccoli, Gianluca; Morocutti, Giorgio; Delise, Pietro; Pinamonti, Bruno; Proclemer, Alessandro; Sinagra, Gianfranco; Nucifora, Gaetano
2015-11-01
Analysis of right ventricular (RV) regional dysfunction by cardiac magnetic resonance (CMR) imaging in arrhythmogenic RV cardiomyopathy (ARVC) may be inadequate because of the complex contraction pattern of the RV. Aim of this study was to determine the use of RV strain and dyssynchrony assessment in ARVC using feature-tracking CMR analysis. Thirty-two consecutive patients with ARVC referred to CMR imaging were included. Thirty-two patients with idiopathic RV outflow tract arrhythmias and 32 control subjects, matched for age and sex to the ARVC group, were included for comparison purpose. CMR imaging was performed to assess biventricular function; feature-tracking analysis was applied to the cine CMR images to assess regional and global longitudinal, circumferential, and radial RV strains and RV dyssynchrony (defined as the SD of the time-to-peak strain of the RV segments). RV global longitudinal strain (-17±5% versus -26±6% versus -29±6%; P<0.001), global circumferential strain (-9±4% versus -12±4% versus -13±5%; P=0.001), and global radial strain (18 [12-26]% versus 22 [15-32]% versus 27 [20-39]%; P=0.015) were significantly lower and SD of the time-to-peak RV strain in all 3 directions were significantly higher among patients with ARVC compared with patients with RV outflow tract arrhythmias and controls. RV global longitudinal strain >-23.2%, SD of the time-to-peak RV longitudinal strain >113.1 ms, and SD of the time-to-peak RV circumferential strain >177.1 ms allowed correct identification of 88%, 75%, and 63% of ARVC patients with no or only minor CMR criteria for ARVC diagnosis. Strain analysis by feature-tracking CMR helps to objectively quantify global and regional RV dysfunction and RV dyssynchrony in patients with ARVC and provides incremental value over conventional cine CMR imaging. © 2015 American Heart Association, Inc.
Spriestersbach, Hendrik; Oh-Icí, Darach; Schmitt, Boris; Berger, Felix; Schmitz, Lothar
2015-01-01
There are significant variations in the published normal values of two-dimensional speckle tracking-derived strain and strain rate. These occur even when authors use the same software. To measure strain, the operator creates a region of interest (ROI) to define the myocardium to be analyzed. The purpose of this study was to test the hypothesis that measurements vary significantly with the chosen ROI width. In 20 healthy subjects (11 males, mean age 17.6 ± 6.18 years) an apical four-chamber view (4CH) and parasternal short-axis view (SAX) were analyzed. Initially ROI width was set automatically by the software. Two subsequent measurements were obtained from each cine loop by choosing the ROI width one step narrower and one step wider than the automatic ROI width. The mean differences between the measurements of narrower and automatic ROI and between automatic and wider ROI were -1.8 ± 0.7% and -0.9 ± 0.5% for global longitudinal strain (SL), -2.2 ± 0.6% and -1.7 ± 0.7% for global circumferential strain (SC), -0.10 ± 0.06/sec and -0.07 ± 0.06/sec for global longitudinal strain rate (SrL), and -0.15 ± 0.09/sec and -0.12 ± 0.07/sec for global circumferential strain rate (SrC) (all P < 0.000). This corresponds to a relative difference to the mean of both measurements of -4.4 to -11.0%. Layer-specific myocardial deformation and curvature dependency lead to an inverse correlation between the chosen ROI width and strain and strain rate measurements. Just one step of ROI-width change leads to a significant bias. Precise ROI-width definition is essential but technical factors limit its feasibility. © 2014, Wiley Periodicals, Inc.
Heermann, Philipp; Hedderich, Dennis M; Paul, Matthias; Schülke, Christoph; Kroeger, Jan Robert; Baeßler, Bettina; Wichter, Thomas; Maintz, David; Waltenberger, Johannes; Heindel, Walter; Bunck, Alexander C
2014-10-07
Fibrofatty degeneration of myocardium in ARVC is associated with wall motion abnormalities. The aim of this study was to examine whether Cardiovascular Magnetic Resonance (CMR) based strain analysis using feature tracking (FT) can serve as a quantifiable measure to confirm global and regional ventricular dysfunction in ARVC patients and support the early detection of ARVC. We enrolled 20 patients with ARVC, 30 with borderline ARVC and 22 subjects with a positive family history but no clinical signs of a manifest ARVC. 10 healthy volunteers (HV) served as controls. 15 ARVC patients received genotyping for Plakophilin-2 mutation (PKP-2), of which 7 were found to be positive. Cine MR datasets of all subjects were assessed for myocardial strain using FT (TomTec Diogenes Software). Global strain and strain rate in radial, circumferential and longitudinal mode were assessed for the right and left ventricle. In addition strain analysis at a segmental level was performed for the right ventricular free wall. RV global longitudinal strain rates in ARVC (-0.68 ± 0.36 sec⁻¹) and borderline ARVC (-0.85 ± 0.36 sec⁻¹) were significantly reduced in comparison with HV (-1.38 ± 0.52 sec⁻¹, p ≤ 0.05). Furthermore, in ARVC patients RV global circumferential strain and strain rates at the basal level were significantly reduced compared with HV (strain: -5.1 ± 2.7 vs. -9.2 ± 3.6%; strain rate: -0.31 ± 0.13 sec(-1) vs. -0.61 ± 0.21 sec⁻¹). Even for patients with ARVC or borderline ARVC and normal RV ejection fraction (n=30) global longitudinal strain rate proved to be significantly reduced compared with HV (-0.9 ± 0.3 vs. -1.4 ± 0.5 sec(-1); p < 0.005). In ARVC patients with PKP-2 mutation there was a clear trend towards a more pronounced impairment in RV global longitudinal strain rate. On ROC analysis RV global longitudinal strain rate and circumferential strain rate at the basal level proved to be the best discriminators between ARVC patients and HV (AUC: 0
Ballo, Piercarlo; Nistri, Stefano; Cameli, Matteo; Papesso, Barbara; Dini, Frank Lloyd; Galderisi, Maurizio; Zuppiroli, Alfredo; Mondillo, Sergio
2014-02-01
The relationships of left ventricular (LV) longitudinal and circumferential systolic dysfunction with diastolic performance in hypertensive patients have never been compared. In 532 asymptomatic hypertensive patients, circumferential function was assessed with the use of midwall fractional shortening (mFS) and stress-corrected mFS (SCmFS), whereas longitudinal function was assessed with the use of left atrioventricular plane displacement (AVPD) and systolic mitral annulus velocity (s'). Early diastolic annular velocity (e') and the E/e' ratio were measured. Global longitudinal and circumferential strain were determined in a subset of 210 patients. e' was linearly related to all systolic indexes (AVPD: R = 0.40; s': R = 0.39; mFS: R = 0.16; SCmFS: R = 0.17; all P < .0001), but the correlations were stronger with longitudinal indexes than with circumferential ones (P < .0001). E/e' was nonlinearly related to AVPD (R = -0.49; P < .0001) and s' (R = -0.34; P < .0001) and showed no relationship with mFS and SCmFS. Longitudinal indexes were superior to circumferential ones in predicting e' <8 cm/s, E/e' <8, and E/e' ≥13. The effect of LV geometry on LV diastolic function was evident among patients with preserved systolic longitudinal function, but was blunted among patients with impaired longitudinal function. In multivariable analyses, only longitudinal indexes remained associated with e' and E/e'. Analyses using strains provided similar results. In asymptomatic hypertensive subjects, LV diastolic performance is independently associated with longitudinal systolic dysfunction, but not with circumferential systolic dysfunction. Subtle longitudinal systolic impairment plays a role in mediating the effect of LV geometry on diastolic performance. These findings may support the need of critically revising the concept of isolated diastolic dysfunction in these patients. Copyright © 2014 Elsevier Inc. All rights reserved.
Circumferential graben and the structural evolution of Alba Mons, Mars
NASA Astrophysics Data System (ADS)
Öhman, Teemu; McGovern, Patrick J.
2014-05-01
Alba Mons is a unique, very extensive but shallow volcanotectonic construct in northern Tharsis, Mars. Numerous models have been presented to explain the formation of Alba Mons and its most characteristic feature, a wristwatch-like pattern of radial and circumferential graben. We used a wide selection of topographic datasets to characterize the fault throw variation on nine topographic transects across the circumferential graben in order to provide observational constraints for the different formation models, and to gain further insight into the evolution of Alba Mons. In most of the transects, summed throws from outwards-facing (away from the center of the volcano) faults are larger than from the inwards-facing (towards the center) ones. Only the very gently sloping western transects show the opposite, emphasizing the east-west-asymmetry of Alba Mons. 10-40% of the observed topographic relief of Alba Mons along the nine transects can be accounted for by this throw difference between the inwards- and outwards-facing faults. These results are consistent with predictions of models suggesting an uplift mechanism to explain the formation of the circumferential graben, but not with models invoking central subsidence. Horizontal extensional strain along the transects varies between 0.5% and 2%, consistent with strain predictions of the late-stage sill complex inflation model of McGovern et al. (McGovern, P.J., Solomon, S.C., Head J.W. III, Smith, D.E., Zuber M.T., Neumann, G.A. [2001]. J. Geophys. Res. 106(E10), 23769-23809).
Kou, Seisyou; Suzuki, Kengo; Akashi, Yoshihiro J; Mizukoshi, Kei; Takai, Manabu; Izumo, Masaki; Shimozato, Takashi; Hayashi, Akio; Ohtaki, Eiji; Osada, Naohiko; Omiya, Kazuto; Nobuoka, Sachihiko; Miyake, Fumihiko
2011-06-01
Left ventricular ejection fraction (LVEF) predicts mortality in patients with chronic heart failure (CHF). However, a weak correlation was found between LVEF and peak oxygen uptake ([Formula: see text]) in CHF patients. Global longitudinal strain measured by two-dimensional (2D) strain is regarded as a more useful predictor of cardiac events than LVEF. We investigated whether 2D strain obtained at rest could predict peak [Formula: see text] in patients with CHF. Fifty-one patients (mean age of 54.0 ± 12.0 years, 14 females, LVEF 46.0 ± 15.0%) with stable CHF underwent resting echocardiography and cardiopulmonary exercise testing. Leg muscle strength was measured for the evaluation of peripheral factors. Global longitudinal strain (GLS) in the apical 4-, 3-, and 2-chamber views and global circumferential strain (GCS) in the parasternal mid short-axis view were measured. In all patients, peak [Formula: see text] correlated with leg muscle strength (r = 0.55, p < 0.0001), LVEF (r = 0.46, p < 0.001), GLS (r = -0.45, p < 0.001), and GCS (r = -0.41, p = 0.005), respectively. No significant correlation was found between the ratio of early transmitral velocity to peak early diastolic mitral annulus velocity (E/E') and peak [Formula: see text]. In the patients with heart failure and reduced LVEF, a multiple stepwise linear regression analysis based on leg muscle strength, LVEF, E/E', GLS, and GCS was performed to identify independent predictors of peak [Formula: see text], resulting in leg muscle strength and GLS (R (2) = 0.888) as independent predictors of peak [Formula: see text]. Global longitudinal strain at rest could possibly predict exercise capacity, which appeared to be more useful than LVEF, E/E', and GCS in CHF patients with reduced LVEF.
Cavallino, Chiara; Rondano, Elisa; Magnani, Andrea; Leva, Lucia; Inglese, Eugenio; Dell'era, Gabriele; Occhetta, Eraldo; Bortnik, Miriam; Marino, Paolo N
2012-06-01
Traditional indexes of LV dyssynchrony (DYS) in pts to be resynchronized are sensitive to noise, while the concordance between LV lead position and site of latest mechanical activation is suggested to be, in these patients, clinically relevant. Both aspects, asynchrony and lead position have been addressed separately but unclear is their potential synergistic role in the clinical evolution of CRT patients. We assessed clinical and echocardiographic outcome, as well as mid-term prognosis, in a population of CHF patients submitted to CRT, stratified according to a novel asynchrony quantitation (temporal uniformity of strain: TUS) method and concordance or not between presumed LV lead position and site of latest mechanical activation. TUS was computed in 85 pts (QRS > 120 ms, EF < 0.35) in whom we measured circumferential and longitudinal strains using speckle-tracking 2D-echocardiography before and 3-6 months after CRT, together with triplane apical LV volumes. Optimal LV lead position in short axis view was defined as concordance of the segment with latest systolic circumferential strain prior-CRT and segment with assumed LV lead position. Assumed LV lead position was defined from a chest X-ray obtained 1 day after implantation and scored as anterior, lateral, posterior or inferior using 2 orthogonal views (antero-posterior and lateral). Following CRT, LV volume decreased (diastolic -8 ± 20%) and EF improved (+6 ± 9%, P < 0.001 for both). Two-way ANOVA revealed TUS improvement post-CRT (+22 ± 68%, P = 0.025), with a clear evidence for more marked asynchrony detectable at circumferential (from 0.53 ± 0.20 to 0.55 ± 0.19) as compared with longitudinal level (from 0.56 ± 0.14 to 0.62 ± 0.14) (P = 0.017). Multivariate analysis revealed that greater baseline asynchrony, as assessed circumferentially (P = 0.079), together with concordance between LV lead position and site of activation (P = 0.012), besides younger age (P = 0.051), longer QRS duration (P = 0
Scattering of circumferential waves in a cracked annulus
NASA Astrophysics Data System (ADS)
Valle, Christine; Qu, Jianmin; Jacobs, Laurence J.
2000-05-01
This paper considers guided waves propagating in the circumferential direction of an annulus with a radial crack, with the objective of developing an ultrasonic technique that can detect and characterize these cracks. Specifically, the finite element method is used to simulate the propagation and scattering of guided circumferential waves in a cracked annulus. This method fosters a better understanding of the wave fields, so that a transducer configuration used in the field can be optimized for crack detection/characterization. Both a point source (simulating laser generated ultrasound) and a distributed source (simulating a PZT transducer) are modeled and compared to corresponding experimental results. Animations (snapshots at different instants in time) of the strain energy field in the annulus are given for various combinations of load profiles, incident angles, and incident frequencies. Results of this paper provide the necessary design guidelines for developing nondestructive ultrasonic techniques for the detection/characterization of radial cracks in cylindrical pressure vessels, gas/oil pipes, and shaft/bearing systems.
Expanded plug method for developing circumferential mechanical properties of tubular materials
Hendrich, William Ray; McAfee, Wallace Jefferson; Luttrell, Claire Roberta
2006-11-28
A method for determining the circumferential properties of a tubular product, especially nuclear fuel cladding, utilizes compression of a polymeric plug within the tubular product to determine strain stress, yield stress and other properties. The process is especially useful in the determination of aging properties such as fuel rod embrittlement after long burn-down.
Obokata, Masaru; Nagata, Yasufumi; Wu, Victor Chien-Chia; Kado, Yuichiro; Kurabayashi, Masahiko; Otsuji, Yutaka; Takeuchi, Masaaki
2016-05-01
Cardiac magnetic resonance (CMR) feature tracking (FT) with steady-state free precession (SSFP) has advantages over traditional myocardial tagging to analyse left ventricular (LV) strain. However, direct comparisons of CMRFT and 2D/3D echocardiography speckle tracking (2/3DEST) for measurement of LV strain are limited. The aim of this study was to investigate the feasibility and reliability of CMRFT and 2D/3DEST for measurement of global LV strain. We enrolled 106 patients who agreed to undergo both CMR and 2D/3DE on the same day. SSFP images at multiple short-axis and three apical views were acquired. 2DE images from three levels of short-axis, three apical views, and 3D full-volume datasets were also acquired. Strain data were expressed as absolute values. Feasibility was highest in CMRFT, followed by 2DEST and 3DEST. Analysis time was shortest in 3DEST, followed by CMRFT and 2DEST. There was good global longitudinal strain (GLS) correlation between CMRFT and 2D/3DEST (r = 0.83 and 0.87, respectively) with the limit of agreement (LOA) ranged from ±3.6 to ±4.9%. Excellent global circumferential strain (GCS) correlation between CMRFT and 2D/3DEST was observed (r = 0.90 and 0.88) with LOA of ±6.8-8.5%. Global radial strain showed fair correlations (r = 0.69 and 0.82, respectively) with LOA ranged from ±12.4 to ±16.3%. CMRFT GCS showed least observer variability with highest intra-class correlation. Although not interchangeable, the high GLS and GCS correlation between CMRFT and 2D/3DEST makes CMRFT a useful modality for quantification of global LV strain in patients, especially those with suboptimal echo image quality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Riffel, Johannes H; Keller, Marius G P; Aurich, Matthias; Sander, Yannick; Andre, Florian; Giusca, Sorin; Aus dem Siepen, Fabian; Seitz, Sebastian; Galuschky, Christian; Korosoglou, Grigorios; Mereles, Derliz; Katus, Hugo A; Buss, Sebastian J
2015-07-01
Myocardial deformation measurement is superior to left ventricular ejection fraction in identifying early changes in myocardial contractility and prediction of cardiovascular outcome. The lack of standardization hinders its clinical implementation. The aim of the study is to investigate a novel standardized deformation imaging approach based on the feature tracking algorithm for the assessment of global longitudinal (GLS) and global circumferential strain (GCS) in echocardiography and cardiac magnetic resonance imaging (CMR). 70 subjects undergoing CMR were consecutively investigated with echocardiography within a median time of 30 min. GLS and GCS were analyzed with a post-processing software incorporating the same standardized algorithm for both modalities. Global strain was defined as the relative shortening of the whole endocardial contour length and calculated according to the strain formula. Mean GLS values were -16.2 ± 5.3 and -17.3 ± 5.3 % for echocardiography and CMR, respectively. GLS did not differ significantly between the two imaging modalities, which showed strong correlation (r = 0.86), a small bias (-1.1 %) and narrow 95 % limits of agreement (LOA ± 5.4 %). Mean GCS values were -17.9 ± 6.3 and -24.4 ± 7.8 % for echocardiography and CMR, respectively. GCS was significantly underestimated by echocardiography (p < 0.001). A weaker correlation (r = 0.73), a higher bias (-6.5 %) and wider LOA (± 10.5 %) were observed for GCS. GLS showed a strong correlation (r = 0.92) when image quality was good, while correlation dropped to r = 0.82 with poor acoustic windows in echocardiography. GCS assessment revealed only a strong correlation (r = 0.87) when echocardiographic image quality was good. No significant differences for GLS between two different echocardiographic vendors could be detected. Quantitative assessment of GLS using a standardized software algorithm allows the direct comparison of values acquired irrespective of the imaging modality. GLS may
High-Intensity Training Improves Global and Segmental Strains in Severe Congestive Heart Failure.
Blumberg, Yair; Ertracht, Offir; Gershon, Itai; Bachner-Hinenzon, Noa; Reuveni, Tali; Atar, Shaul
2017-05-01
High-intensity training (HIT) is superior to moderate aerobic training (MAT) for improving quality of life in congestive heart failure (CHF) patients. Speckle-tracking echocardiography (STE) has recently been suggested for estimation of left ventricle global and regional function. We evaluated the utility of STE for characterizing differences in cardiac function following MAT or HIT in a CHF rat model. After baseline physiologic assessment, CHF was induced by means of coronary artery ligation in Sprague-Dawley rats. Repeated measurements confirmed the presence of CHF (ejection fraction 52 ± 10%, global circumferential strain (GCS) 10.5 ± 4, and maximal oxygen uptake (V˙O 2 max ) 71 ± 11 mL⋅min -1 ⋅kg -1 ; P < .001 vs baseline for all). Subsequently, rats were divided into training protocols: sedentary (SED), MAT, or HIT. After the training period, rats underwent the same measurements and were killed. Training intensity improved V˙O 2 max (73 ± 13 mL⋅min -1 ⋅kg -1 in MAT [P < .01 vs baseline] and 82 ± 6 mL⋅min -1 ⋅kg -1 in HIT [P < .05 vs baseline or SED] and ejection fraction (50 ± 21% in MAT [P < .001 vs baseline] and 66 ± 7% in HIT [P > .05 vs baseline]). In addition, strains of specific segments adjacent to the infarct zone regained basal values (P > .05 vs baseline), whereas global cardiac functional parameters as assessed with the use of 2-dimensional echocardiography did not improve. High-intensity exercise training improved function in myocardial segments remote from the scar, which resulted in compensatory cardiac remodeling. This effect is prominent, yet it could be detected only with the use of STE. Copyright © 2017 Elsevier Inc. All rights reserved.
Ballo, Piercarlo; Nistri, Stefano; Bocelli, Arianna; Mele, Donato; Dini, Frank L; Galderisi, Maurizio; Zuppiroli, Alfredo; Mondillo, Sergio
2016-01-15
Assessment of left ventricular circumferential (LVcirc) systolic function by standard echocardiography can be performed by estimating midwall fractional shortening (mFS) and stress-corrected mFS (ScmFS). Their determination is based on spherical or cylindrical LV geometric models, which often yield discrepant values. We developed a new model based on a more realistic truncated ellipsoid (TE) LV shape, and explored the concordance between models among hypertensive patients. We also compared the relationships of different mFS and ScmFS estimates with indexes of LVcirc systolic strain. In 364 hypertensive subjects, mFS was determined using the spherical (mFSspher), cylindrical (mFScyl), and TE model (mFSTE). Corresponding values of ScmFSspher, ScmFScyl, and ScmFSTE were obtained. Global circumferential strain (GCS) and systolic strain rate (GCSR) were also measured by speckle tracking. The three models showed poor concordance for the estimation of mFS, with average differences ranging between 11% and 30% and wide limits of agreement. Similar results were found for ScmFS, where reclassification rates for the identification of abnormal LVcirc systolic function ranged between 18% and 29%. When tested against strain indexes, mFSTE and ScmFSTE showed the best correlations (R=0.81 and R=0.51, p<0.0001 for both) with GCS and GCSR. Multivariable analysis confirmed that mFSTE and ScmFSTE showed the strongest independent associations with LVcirc strain measures. Substantial discrepancies in LVcirc midwall systolic indexes exist between different models, supporting the need of model-specific normative data. The use of the TE model might provide indexes that show the best associations with established strain measures of LVcirc systolic function. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Wang, Qingqing; Ma, Wenyan; Xia, Jizhu
2018-01-24
The aim of this study was to detect left ventricular (LV) structure and function abnormalities in patients with type 2 diabetes mellitus with or without nonalcoholic fatty liver (NAFL) using 3-dimensional speckle-tracking echocardiography. Eighty patients with type 2 diabetes and a normal LV ejection fraction (≥55%), including 40 with coexistent NAFL, and 40 age- and sex-matched control participants were recruited. Conventional echocardiography and 3-dimensional speckle-tracking echocardiography were performed, and global longitudinal strain, global circumferential strain, global area strain, and global radial strain values were measured. Significant differences in 2-dimensional LV functional patterns were found among the 3 groups (P = .031), and LV hypertrophy was the most prevalent in patients with diabetes and NAFL. The patients with diabetes only had significantly lower global longitudinal strain, global circumferential strain, and global radial strain than the controls (all P < .05). The patients with diabetes and NAFL had severely lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain than the controls (all P < .001), and they also had severely lower global longitudinal strain, global area strain, and global radial strain than the patients with diabetes only (all P < 0.001). The hemoglobin A 1c level and NAFL were independently associated with strain values in all patients with diabetes. The strain values in multiple directions (≥2 of global longitudinal, global circumferential, global area, and global radial strain) decreased significantly in the patients with diabetes and moderate and severe NAFL compared to those with mild NAFL (all P < .05). Nonalcoholic fatty liver could aggravate LV hypertrophy and dysfunction in patients with type 2 diabetes. The combined application of conventional and 3-dimensional speckle-tracking echocardiography could detect these asymptomatic
Sade, Leyla Elif; Hazirolan, Tuncay; Kozan, Hatice; Ozdemir, Handan; Hayran, Mutlu; Eroglu, Serpil; Pirat, Bahar; Sezgin, Atilla; Muderrisoglu, Haldun
2018-04-14
The aim of this study was to test the hypothesis that echocardiographic strain imaging, by tracking subtle alterations in myocardial function, and cardiac magnetic resonance T1 mapping, by quantifying tissue properties, are useful and complement each other to detect acute cellular rejection in heart transplant recipients. Noninvasive alternatives to endomyocardial biopsy are highly desirable to monitor acute cellular rejection. Surveillance endomyocardial biopsies, catheterizations, and echocardiograms performed serially according to institutional protocol since transplantation were retrospectively reviewed. Sixteen-segment global longitudinal strain (GLS) and circumferential strain were measured before, during, and after the first rejection and at 2 time points for patients without rejection using Velocity Vector Imaging for the first part of the study. The second part, with cardiac magnetic resonance added to the protocol, served to validate previously derived strain cutoffs, examine the progression of strain over time, and to determine the accuracy of strain and T1 measurements to define acute cellular rejection. All tests were performed within 48 h. Median time to first rejection (16 grade 1 rejection, 15 grade ≥2 rejection) was 3 months (interquartile range: 3 to 36 months) in 49 patients. GLS and global circumferential strain worsened significantly during grade 1 rejection and ≥2 rejection and were independent predictors of any rejection. In the second part of the study, T1 time ≥1,090 ms, extracellular volume ≥32%, GLS >-14%, and global circumferential strain ≥-24% had 100% sensitivity and 100% negative predictive value to define grade ≥2 rejection with 70%, 63%, 55%, and 35% positive predictive values, respectively. The combination of GLS >-16% and T1 time ≥1,060 ms defined grade 1 rejection with 91% sensitivity and 92% negative predictive value. After successful treatment, T1 times decreased significantly. T1 mapping and
Smith, Danielle N; Bonagura, John D; Culwell, Nicole M; Schober, Karsten E
2012-03-01
The presence of left ventricular (LV) systolic dysfunction may influence prognosis or therapy in dogs with chronic mitral regurgitation (MR). Assessment of LV function in MR by conventional echocardiography is confounded by altered ventricular loading. Myocardial deformation (strain) imaging might offer more sensitive estimates of LV function in this disease. Prospectively measure myocardial strain in dogs with asymptomatic MR compared to a control group. Forty healthy dogs (3.5-11.5 kg): 20 Controls; 20 dogs with MR and LV remodeling (Stage B2), were evaluated in this study. LV size and function were assessed in a short-axis plane. Segmental radial strain and strain rate and global circumferential strain were measured using a 2D echocardiographic speckle-tracking algorithm (GE EchoPAC). Groups were compared using Bonferroni t-tests. Influences of heart rate and body weight were explored with linear regression. The MR group had significantly greater mean values for heart rate, LV size, and LV systolic function. Specifically, LV diastolic diameter, diastole area, shortening fraction, averaged peak systolic and early diastolic radial strain, global circumferential strain, and averaged radial strain rate were significantly greater in the MR group (p < 0.015 to p < 0.001). Strain was unrelated to weight, but weakly correlated with heart rate. Similar to conventional indices, Stage B2 dogs with MR demonstrate hyperdynamic deformation in the short-axis plane. Short-axis strain variables measured by 2D speckle tracking are greater than for controls of similar age and weight. These results imply either preserved LV systolic function or that LV dysfunction is masked by altered ventricular loading. Copyright © 2012 Elsevier B.V. All rights reserved.
Airway Strain during Mechanical Ventilation in an Intact Animal Model
Sinclair, Scott E.; Molthen, Robert C.; Haworth, Steve T.; Dawson, Christopher A.; Waters, Christopher M.
2007-01-01
Rationale: Mechanical ventilation with large tidal volumes causes ventilator-induced lung injury in animal models. Little direct evidence exists regarding the deformation of airways in vivo during mechanical ventilation, or in the presence of positive end-expiratory pressure (PEEP). Objectives: To measure airway strain and to estimate airway wall tension during mechanical ventilation in an intact animal model. Methods: Sprague-Dawley rats were anesthetized and mechanically ventilated with tidal volumes of 6, 12, and 25 cm3/kg with and without 10–cm H2O PEEP. Real-time tantalum bronchograms were obtained for each condition, using microfocal X-ray imaging. Images were used to calculate circumferential and longitudinal airway strains, and on the basis of a simplified mathematical model we estimated airway wall tensions. Measurements and Main Results: Circumferential and longitudinal airway strains increased with increasing tidal volume. Levels of mechanical strain were heterogeneous throughout the bronchial tree. Circumferential strains were higher in smaller airways (less than 800 μm). Airway size did not influence longitudinal strain. When PEEP was applied, wall tensions increased more rapidly than did strain levels, suggesting that a “strain limit” had been reached. Airway collapse was not observed under any experimental condition. Conclusions: Mechanical ventilation results in significant airway mechanical strain that is heterogeneously distributed in the uninjured lung. The magnitude of circumferential but not axial strain varies with airway diameter. Airways exhibit a “strain limit” above which an abrupt dramatic rise in wall tension is observed. PMID:17626911
NASA Technical Reports Server (NTRS)
Ludwig, L. P. (Inventor)
1981-01-01
A circumferential shaft seal comprising two sealing rings held to a rotating shaft by means of a surrounding elastomeric band is disclosed. The rings are segmented and are of a rigid sealing material such as carbon or a polyimide and graphite fiber composite.
49 CFR 178.345-7 - Circumferential reinforcements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... stiffeners which prevent visual inspection of the cargo tank shell are prohibited on cargo tank motor... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.345-7 Circumferential reinforcements. (a) A cargo tank with a shell thickness of less than 3/8 inch must be circumferentially...
49 CFR 178.345-7 - Circumferential reinforcements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... stiffeners which prevent visual inspection of the cargo tank shell are prohibited on cargo tank motor... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.345-7 Circumferential reinforcements. (a) A cargo tank with a shell thickness of less than 3/8 inch must be circumferentially...
49 CFR 178.345-7 - Circumferential reinforcements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... stiffeners which prevent visual inspection of the cargo tank shell are prohibited on cargo tank motor... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.345-7 Circumferential reinforcements. (a) A cargo tank with a shell thickness of less than 3/8 inch must be circumferentially...
49 CFR 178.345-7 - Circumferential reinforcements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... stiffeners which prevent visual inspection of the cargo tank shell are prohibited on cargo tank motor... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.345-7 Circumferential reinforcements. (a) A cargo tank with a shell thickness of less than 3/8 inch must be circumferentially...
49 CFR 178.345-7 - Circumferential reinforcements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... stiffeners which prevent visual inspection of the cargo tank shell are prohibited on cargo tank motor... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.345-7 Circumferential reinforcements. (a) A cargo tank with a shell thickness of less than 3/8 inch must be circumferentially...
Axial-Loading Circumferential Dovetail Turbine-Blade Mount
NASA Technical Reports Server (NTRS)
Pierce, Martin J.; Ward, Steven D.; Eskridge, Ronald R.
1992-01-01
In new configuration, retaining ring holds base of blades in circumferential dovetail slot. Blades inserted axially via loading slots into circumferential dovetail slot. Ring placed over loading slots and fastened with split ring held by arm of disk. Blades less likely to be shaken loose during operation.
NASA Technical Reports Server (NTRS)
Ludwig, L. P. (Inventor)
1980-01-01
A circumferential shaft seal is described which comprises two sealing rings held to a rotating shaft by means of a surrounding elastomeric band. The rings are segmented and are of a rigid sealing material such as carbon or a polyimide and graphite fiber composite.
Strain measurement in the wavy-ply region of an externally pressurized cross-ply composite ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gascoigne, H.E.; Abdallah, M.G.
1996-07-01
Ply-level strains are determined in the cross-section of an externally pressurized cross-ply (3:1 circumferential to axial fiber ratio) graphite-epoxy ring containing an isolated circumferential wavy region. A special test fixture was used which permitted measuring orthogonal displacement components in the wavy area using moire interferometry as the pressure was increased. Strain components were determined at selected locations in the wavy area up to approximately90% of failure pressure. The study shows: (1) large interlaminar shear strains, which are non-existent in the perfect ring, are present near the wave inflection points; (2) the wavy plies generate increased interlaminar normal compressive strains inmore » both circumferential and axial plies along a radial line coinciding with maximum wave amplitude; and (3) nonlinear strain response begins at approximately 60% of failure pressure.« less
NASA Astrophysics Data System (ADS)
Jiang, Shanchao; Wang, Jing; Sui, Qingmei
2015-11-01
One novel distinguishable circumferential inclined direction tilt sensor is demonstrated by incorporating two strain sensitivity fiber Bragg gratings (FBGs) with two orthogonal triangular cantilever beam and using one fiber Bragg grating (FBG) as temperature compensation element. According to spatial vector and space geometry, theory calculation model of the proposed FBG tilt sensor which can be used to obtain the azimuth and tile angle of the inclined direction is established. To obtain its measuring characteristics, calibration experiment on one prototype of the proposed FBG tilt sensor is carried out. After temperature sensitivity experiment data analysis, the proposed FBG tilt sensor exhibits excellent temperature compensation characteristics. In 2-D tilt angle experiment, tilt measurement sensitivities of these two strain sensitivity FBGs are 140.85°/nm and 101.01°/nm over a wide range of 60º. Further, azimuth and tile angle of the inclined direction can be obtained by the proposed FBG tilt sensor which is verified in circumferential angle experiment. Experiment data show that relative errors of azimuth are 0.55% (positive direction) and 1.14% (negative direction), respectively, and relative errors of tilt angle are all less than 3%. Experiment results confirm that the proposed distinguishable circumferential inclined direction tilt sensor based on FBG can achieve azimuth and tile angle measurement with wide measuring range and high accuracy.
Okada, Kazunori; Kaga, Sanae; Mikami, Taisei; Masauzi, Nobuo; Abe, Ayumu; Nakabachi, Masahiro; Yokoyama, Shinobu; Nishino, Hisao; Ichikawa, Ayako; Nishida, Mutsumi; Murai, Daisuke; Hayashi, Taichi; Shimizu, Chikara; Iwano, Hiroyuki; Yamada, Satoshi; Tsutsui, Hiroyuki
2017-05-01
We analyzed the waveform of systolic strain and strain-rate curves to find a characteristic left ventricular (LV) myocardial contraction pattern in patients with hypertrophic cardiomyopathy (HCM), and evaluated the utility of these parameters for the differentiation of HCM and LV hypertrophy secondary to hypertension (HT). From global strain and strain-rate curves in the longitudinal and circumferential directions, the time from mitral valve closure to the peak strains (T-LS and T-CS, respectively) and the peak systolic strain rates (T-LSSR and T-CSSR, respectively) were measured in 34 patients with HCM, 30 patients with HT, and 25 control subjects. The systolic strain-rate waveform was classified into 3 patterns ("V", "W", and "√" pattern). In the HCM group, T-LS was prolonged, but T-LSSR was shortened; consequently, T-LSSR/T-LS ratio was distinctly lower than in the HT and control groups. The "√" pattern of longitudinal strain-rate waveform was more frequently seen in the HCM group (74 %) than in the control (4 %) and HT (20 %) groups. Similar but less distinct results were obtained in the circumferential direction. To differentiate HCM from HT, the sensitivity and specificity of the T-LSSR/T-LS ratio <0.34 and the "√"-shaped longitudinal strain-rate waveform were 85 and 63 %, and 74 and 80 %, respectively. In conclusion, in patients with HCM, a reduced T-LSSR/T-LS ratio and a characteristic "√"-shaped waveform of LV systolic strain rate was seen, especially in the longitudinal direction. The timing and waveform analyses of systolic strain rate may be useful to distinguish between HCM and HT.
Weigel, Julia K; Steinmann, Daniel; Emerich, Philipp; Stahl, Claudius A; v Elverfeldt, Dominik; Guttmann, Josef
2011-02-01
Perfluorocarbons (PFC) are biologically and chemically inert fluids with high oxygen and CO(2) carrying capacities. Their use as liquid intrapulmonary gas carriers during liquid ventilation has been investigated. We established a method of high resolution 3D-(19)F-MRI of the totally PFC-filled lung. The goal of this study was to investigate longitudinal and circumferential airway strain in the setting of increasing airway pressures on 3D-(19)F-MR images of the PFC-filled lung. Sixteen female Wistar rats were euthanized and the liquid perfluorocarbon FC-84 instilled into their lungs. 3D-(19)F-MRI was performed at various intrapulmonary pressures. Measurements of bronchial length and cross-sectional area were obtained from transversal 2D images for each pressure range. Changes in bronchial area were used to determine circumferential strain, while longitudinal strain was calculated from changes in bronchial length. Our method of 3D-(19)F-MRI allowed clear visualization of the great bronchi. Longitudinal strain increased significantly up to 31.1 cmH(2)O. The greatest strain could be found in the range of low airway pressures. Circumferential strain increased strongly with the initial pressure rise, but showed no significant changes above 10.4 cmH(2)O. Longitudinal strain was generally higher in distal airways, while circumferential strain showed no difference. Analysis of mechanical characteristics showed that longitudinal and circumferential airway expansion occurred in an anisotropic fashion. Whereas longitudinal strain still increased with higher pressures, circumferential strain quickly reached a 'strain limit'. Longitudinal strain was higher in distal bronchi, as dense PFCs gravitate to dependent, in this case to dorso-basal parts of the lung, acting as liquid positive end expiratory pressure.
Baeßler, Bettina; Schaarschmidt, Frank; Dick, Anastasia; Michels, Guido; Maintz, David; Bunck, Alexander C
2016-01-01
The present study aims to evaluate the diagnostic value of cardiac magnetic resonance (CMR) feature tracking (FT) derived strain-analysis of both ventricles in patients with acute myocarditis (ACM) in order to improve its currently still challenging non-invasive diagnosis. CMR cine data of 31 patients with clinically suspected ACM and confirmation of diagnosis by CMR according to the Lake Louise criteria as well as 14 patients with clinically diagnosed ACM but inconspicuous CMR were retrospectively analyzed. 20 healthy volunteers (HV) served as a control. Analysis of global longitudinal, circumferential and radial strain and strain rate of both ventricles was performed in one long-axis and three short-axis slices using a dedicated FT-software (TomTec Imaging Systems). Patients with ACM showed significantly reduced LV longitudinal strain (-12.7 ± 6.5 vs. -16.8 ± 5.9%, p=0.021) and LV circumferential strain (LVCirStrain; -22.9 ± 5.7 vs. -27.8 ± 4.4 %, p<0.001) compared to HV. Conversely, they showed improved basal RV circumferential strain rate (BasalRVCirSR; -0.70 ± 0.23 vs. -0.47 ± 0.31s(-1), p=0.009). In ACM patients with preserved EF, BasalRVCirSR was significantly increased compared to HV while LV strain was not significantly different between both groups. In multinominal logistic regression analysis, LVCirStrain and BasalRVCirSR proved to be the best independent predictors of ACM with preserved EF. A combined cut-off of -0.53s(-1) for BasalRVCirSR and of -29.0% for LVCirStrain allowed a classification of ACM patients with preserved EF with a sensitivity of 89% and a specificity of 80%. Also patients with clinical ACM but inconspicuous CMR showed a significantly improved BasalRVCirSR and a cut-off of -0.77s(-1) allowed a classification of ACM patients with a sensitivity of 70% and a specificity of 90%, while all other CMR parameters were normal. The defined cut-offs for LVCirStrain and BasalRVCirSR allow a prediction of ACM with high sensitivity and
NASA Astrophysics Data System (ADS)
Bland, Michael T.; McKinnon, William B.
2015-01-01
The ubiquity of tectonic features formed in extension, and the apparent absence of ones formed in contraction, has led to the hypothesis that Ganymede has undergone global expansion in its past. Determining the magnitude of such expansion is challenging however, and extrapolation of locally or regionally inferred strains to global scales often results in strain estimates that exceed those based on global constraints. Here we use numerical simulations of groove terrain formation to develop a strain history for Ganymede that is generally consistent at local, regional, and global scales. These simulations reproduce groove-like amplitudes, wavelengths, and average slopes at modest regional extensions (10-15%). The modest strains are more consistent with global constraints on Ganymede's expansion. Yet locally, we also find that surface strains can be much larger (30-60%) in the same simulations, consistent with observations of highly-extended impact craters. Thus our simulations satisfy both the smallest-scale and largest-scale inferences of strain on Ganymede. The growth rate of the topography is consistent with (or exceeds) predictions of analytical models, and results from the use of a non-associated plastic rheology that naturally permits localization of brittle failure (plastic strain) into linear fault-like shear zones. These fault-like zones are organized into periodically-spaced graben-like structures with stepped, steeply-dipping faults. As in previous work, groove amplitudes and wavelengths depend on both the imposed heat flux and surface temperature, but because our brittle strength increases with depth, we find (for the parameters explored) that the growth rate of topography is initially faster for lower heat flows. We observe a transition to narrow rifting for higher heat flows and larger strains, which is a potential pathway for breakaway margin or band formation.
Maceira, Alicia M; Tuset-Sanchis, Luis; López-Garrido, Miguel; San Andres, Marta; López-Lereu, M Pilar; Monmeneu, Jose V; García-González, M Pilar; Higueras, Laura
2018-05-01
The measurement of myocardial deformation by strain analysis is an evolving tool to quantify regional and global myocardial function. To assess the feasibility and reproducibility of myocardial strain/strain rate measurements with magnetic resonance feature tracking (MR-FT) in healthy subjects and in patient groups. Prospective study. Sixty patients (20 hypertensives with left ventricular (LV) hypertrophy (H); 20 nonischemic dilated cardiomyopathy (D); 20 ischemic heart disease (I); as well as 20 controls (C) were included, 10 men and 10 women in each group. A 1.5T MR protocol including steady-state free precession (SSFP) cine sequences in the standard views and late enhancement sequences. LV volumes, mass, global and regional radial, circumferential, and longitudinal strain/strain rate were measured using CVI42 software. The analysis time was recorded. Intraobserver and interobserver agreement and intraclass correlation coefficients (ICC) were obtained for reproducibility assessment as well as differences according to gender and group of pertinence. Strain/strain rate analysis could be achieved in all subjects. The average analysis time was 14 ± 3 minutes. The average intraobserver ICC was excellent (ICC >0.90) for strain and good (ICC >0.75) for strain rate. Reproducibility of strain measurements was good to excellent (ICC >0.75) for all groups of subjects and both genders. Reproducibility of strain measurements was good for basal segments (ICC >0.75) and excellent for middle and apical segments (ICC >0.90). Reproducibility of strain rate measurements was moderate for basal segments (ICC >0.50) and good for middle and apical segments. MR-FT for strain/strain rate analysis is a feasible and highly reproducible technique. CVI42 FT analysis was equally feasible and reproducible in various pathologies and between genders. Better reproducibility was seen globally for middle and apical segments, which needs further clarification. 3 Technical Efficacy Stage 2 J
Left ventricular strain and its pattern estimated from cine CMR and validation with DENSE
NASA Astrophysics Data System (ADS)
Gao, Hao; Allan, Andrew; McComb, Christie; Luo, Xiaoyu; Berry, Colin
2014-07-01
Measurement of local strain provides insight into the biomechanical significance of viable myocardium. We attempted to estimate myocardial strain from cine cardiovascular magnetic resonance (CMR) images by using a b-spline deformable image registration method. Three healthy volunteers and 41 patients with either recent or chronic myocardial infarction (MI) were studied at 1.5 Tesla with both cine and DENSE CMR. Regional circumferential and radial left ventricular strains were estimated from cine and DENSE acquisitions. In all healthy volunteers, there was no difference for peak circumferential strain (- 0.18 ± 0.04 versus - 0.18 ± 0.03, p = 0.76) between cine and DENSE CMR, however peak radial strain was overestimated from cine (0.84 ± 0.37 versus 0.49 ± 0.2, p < 0.01). In the patient study, the peak strain patterns predicted by cine were similar to the patterns from DENSE, including the strain evolution related to recovery time and strain patterns related to MI scar extent. Furthermore, cine-derived strain disclosed different strain patterns in MI and non-MI regions, and regions with transmural and non-transmural MI as DENSE. Although there were large variations with radial strain measurements from cine CMR images, useful circumferential strain information can be obtained from routine clinical CMR imaging. Cine strain analysis has potential to improve the diagnostic yield from routine CMR imaging in clinical practice.
Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Zhang, Jin-Ping; Wu, Wei-Chun; Wang, Hao
2015-10-01
The purpose of this study was to investigate the diagnostic value of 3-dimensional (3D) speckle-tracking echocardiography for estimating left ventricular filling pressure in patients with coronary artery disease (CAD) and a preserved left ventricular ejection fraction. Altogether, 84 patients with CAD and 30 age- and sex-matched healthy control participants in sinus rhythm were recruited prospectively. All participants underwent conventional and 3D speckle-tracking echocardiography. Global strain values were automatically calculated by 3D speckle-tracking analysis. The left ventricular end-diastolic pressure (LVEDP) was determined invasively by left heart catheterization. Echocardiography and cardiac catheterization were performed within 24 hours. Compared with the controls, patients with CAD showed lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain. Patients with CAD who had an elevated LVEDP had much lower levels of all 4 3D-speckle-tracking echocardiographic variables. Pearson correlation analysis revealed that the LVEDP correlated positively with the early transmitral flow velocity/early diastolic myocardial velocity (E/E') ratio, global longitudinal strain, global circumferential strain, and global area strain. It correlated negatively with global radial strain. Receiver operating characteristic curve analysis revealed that these 3D speckle-tracking echocardiographic indices could effectively predict elevated left ventricular filling pressure (LVEDP >15 mm Hg) in patients with CAD (areas under the curve: global longitudinal strain, 0.78; global radial strain, 0.77; global circumferential strain, 0.75; and global area strain, 0.74). These parameters, however, showed no advantages over the commonly used E/E' ratio (area under the curve, 0.84). Three-dimensional speckle-tracking echocardiography was a practical technique for predicting elevated left ventricular filling pressure, but it might not be
NASA Astrophysics Data System (ADS)
Portnov, G. G.; Bakis, Ch. E.
2000-01-01
Fiber reinforced elastomeric matrix composites (EMCs) offer several potential advantages for construction of rotors for flywheel energy storage systems. One potential advantage, for safety considerations, is the existence of maximum stresses near the outside radius of thick circumferentially wound EMC disks, which could lead to a desirable self-arresting failure mode at ultimate speeds. Certain unidirectionally reinforced EMCs, however, have been noted to creep readily under the influence of stress transverse to the fibers. In this paper, stress redistribution in a spinning thick disk made of a circumferentially filament wound EMC material on a small rigid hub has been analyzed with the assumption of total radial stress relaxation due to radial creep. It is shown that, following complete relaxation, the circumferential strains and stresses are maximized at the outside radius of the disk. Importantly, the radial tensile strains are three times greater than the circumferential strains at any given radius. Therefore, a unidirectional EMC material system that can safely endure transverse tensile creep strains of at least three times the elastic longitudinal strain capacity of the same material is likely to maintain the theoretically safe failure mode despite complete radial stress relaxation.
Bland, Michael T.; McKinnon, W. B.
2015-01-01
The ubiquity of tectonic features formed in extension, and the apparent absence of ones formed in contraction, has led to the hypothesis that Ganymede has undergone global expansion in its past. Determining the magnitude of such expansion is challenging however, and extrapolation of locally or regionally inferred strains to global scales often results in strain estimates that exceed those based on global constraints. Here we use numerical simulations of groove terrain formation to develop a strain history for Ganymede that is generally consistent at local, regional, and global scales. These simulations reproduce groove-like amplitudes, wavelengths, and average slopes at modest regional extensions (10–15%). The modest strains are more consistent with global constraints on Ganymede’s expansion. Yet locally, we also find that surface strains can be much larger (30–60%) in the same simulations, consistent with observations of highly-extended impact craters. Thus our simulations satisfy both the smallest-scale and largest-scale inferences of strain on Ganymede. The growth rate of the topography is consistent with (or exceeds) predictions of analytical models, and results from the use of a non-associated plastic rheology that naturally permits localization of brittle failure (plastic strain) into linear fault-like shear zones. These fault-like zones are organized into periodically-spaced graben-like structures with stepped, steeply-dipping faults. As in previous work, groove amplitudes and wavelengths depend on both the imposed heat flux and surface temperature, but because our brittle strength increases with depth, we find (for the parameters explored) that the growth rate of topography is initially faster for lower heat flows. We observe a transition to narrow rifting for higher heat flows and larger strains, which is a potential pathway for breakaway margin or band formation.
Demonstration test of burner liner strain measurements using resistance strain gages
NASA Technical Reports Server (NTRS)
Grant, H. P.; Anderson, W. L.
1984-01-01
A demonstration test of burner liner strain measurements using resistance strain gages as well as a feasibility test of an optical speckle technique for strain measurement are presented. The strain gage results are reported. Ten Kanthal A-1 wire strain gages were used for low cycle fatigue strain measurements to 950 K and .002 apparent strain on a JT12D burner can in a high pressure (10 atmospheres) burner test. The procedure for use of the strain gages involved extensive precalibration and postcalibration to correct for cooling rate dependence, drift, and temperature effects. Results were repeatable within + or - .0002 to .0006 strain, with best results during fast decels from 950 K. The results agreed with analytical prediction based on an axisymmetric burner model, and results indicated a non-uniform circumferential distribution of axial strain, suggesting temperature streaking.
Early development of the circumferential axonal pathway in mouse and chick spinal cord.
Holley, J A
1982-03-10
The early development of the circumferential axonal pathway in the brachial and lumbar spinal cord of mouse and chick embryos was studied by scanning and transmission electron microscopy. The cellular processes which comprise this pathway grow in the transverse plane and along the lateral margin of the marginal zone (i.e., circumferentially oriented), as typified by the early embryonic commissural axons. The first formative event observed was in the ventrolateral margin of the primitive spinal cord ventricular zone. Cellular processes were found near the external limiting membrane that appeared to grow a variable distance either dorsally or ventrally. Later in development, presumptive motor column neurons migrated into the ventrolateral region, distal to these early circumferentially oriented processes. Concurrently, other circumferentially oriented perikarya and processes appeared along the dorsolateral margin. Due to their aligned sites of origin and parallel growth, the circumferential processes formed a more or less continuous line or pathway, which in about 10% of the scanned specimens could be followed along the entire lateral margin of the embryonic spinal cord. Several specimens later in development had two sets of aligned circumferential processes in the ventral region. Large numbers of circumferential axons were then found to follow the preformed pathway by fasciculation, after the primitive motor column had become established. Since the earliest circumferential processes appeared to differentiate into axons and were found nearly 24 hours prior to growth of most circumferential axons, their role in guidance as pioneering axons was suggested.
Circumferentially aligned fibers guided functional neoartery regeneration in vivo.
Zhu, Meifeng; Wang, Zhihong; Zhang, Jiamin; Wang, Lina; Yang, Xiaohu; Chen, Jingrui; Fan, Guanwei; Ji, Shenglu; Xing, Cheng; Wang, Kai; Zhao, Qiang; Zhu, Yan; Kong, Deling; Wang, Lianyong
2015-08-01
An ideal vascular graft should have the ability to guide the regeneration of neovessels with structure and function similar to those of the native blood vessels. Regeneration of vascular smooth muscle cells (VSMCs) with circumferential orientation within the grafts is crucial for functional vascular reconstruction in vivo. To date, designing and fabricating a vascular graft with well-defined geometric cues to facilitate simultaneously VSMCs infiltration and their circumferential alignment remains a great challenge and scarcely reported in vivo. Thus, we have designed a bi-layered vascular graft, of which the internal layer is composed of circumferentially aligned microfibers prepared by wet-spinning and an external layer composed of random nanofibers prepared by electrospinning. While the internal circumferentially aligned microfibers provide topographic guidance for in vivo regeneration of circumferentially aligned VSMCs, the external random nanofibers can offer enhanced mechanical property and prevent bleeding during and after graft implantation. VSMCs infiltration and alignment within the scaffold was then evaluated in vitro and in vivo. Our results demonstrated that the circumferentially oriented VSMCs and longitudinally aligned ECs were successfully regenerated in vivo after the bi-layered vascular grafts were implanted in rat abdominal aorta. No formation of thrombosis or intimal hyperplasia was observed up to 3 month post implantation. Further, the regenerated neoartery exhibited contraction and relaxation property in response to vasoactive agents. This new strategy may bring cell-free small diameter vascular grafts closer to clinical application. Copyright © 2015 Elsevier Ltd. All rights reserved.
Satriano, Alessandro; Heydari, Bobak; Narous, Mariam; Exner, Derek V; Mikami, Yoko; Attwood, Monica M; Tyberg, John V; Lydell, Carmen P; Howarth, Andrew G; Fine, Nowell M; White, James A
2017-12-01
Two-dimensional (2D) strain analysis is constrained by geometry-dependent reference directions of deformation (i.e. radial, circumferential, and longitudinal) following the assumption of cylindrical chamber architecture. Three-dimensional (3D) principal strain analysis may overcome such limitations by referencing intrinsic (i.e. principal) directions of deformation. This study aimed to demonstrate clinical feasibility of 3D principal strain analysis from routine 2D cine MRI with validation to strain from 2D tagged cine analysis and 3D speckle tracking echocardiography. Thirty-one patients undergoing cardiac MRI were studied. 3D strain was measured from routine, multi-planar 2D cine SSFP images using custom software designed to apply 4D deformation fields to 3D cardiac models to derive principal strain. Comparisons of strain estimates versus those by 2D tagged cine, 2D non-tagged cine (feature tracking), and 3D speckle tracking echocardiography (STE) were performed. Mean age was 51 ± 14 (36% female). Mean LV ejection fraction was 66 ± 10% (range 37-80%). 3D principal strain analysis was feasible in all subjects and showed high inter- and intra-observer reproducibility (ICC range 0.83-0.97 and 0.83-0.98, respectively-p < 0.001 for all directions). Strong correlations of minimum and maximum principal strain were respectively observed versus the following: 3D STE estimates of longitudinal (r = 0.81 and r = -0.64), circumferential (r = 0.76 and r = -0.58) and radial (r = -0.80 and r = 0.63) strain (p < 0.001 for all); 2D tagged cine estimates of longitudinal (r = 0.81 and r = -0.81), circumferential (r = 0.87 and r = -0.85), and radial (r = -0.76 and r = 0.81) strain (p < 0.0001 for all); and 2D cine (feature tracking) estimates of longitudinal (r = 0.85 and -0.83), circumferential (r = 0.88 and r = -0.87), and radial strain (r = -0.79 and r = 0.84, p < 0.0001 for all). 3D
O'Grady, Gregory; Du, Peng; Paskaranandavadivel, Nira; Angeli, Timothy R.; Lammers, Wim JEP; Asirvatham, Samuel J.; Windsor, John A.; Farrugia, Gianrico; Pullan, Andrew J.; Cheng, Leo K.
2012-01-01
Background Gastric slow waves propagate aborally as rings of excitation. Circumferential propagation does not normally occur, except at the pacemaker region. We hypothesized that: i) the unexplained high-velocity, high-amplitude activity associated with the pacemaker region is a consequence of circumferential propagation; ii) rapid, high-amplitude circumferential propagation emerges during gastric dysrhythmias; iii) the driving network conductance might switch between ICC-MP and circular ICC-IM during circumferential propagation; iv) extracellular amplitudes and velocities are correlated. Methods An experimental-theoretical study was performed. HR gastric mapping was performed in pigs during normal activation, pacing and dysrhythmia. Activation profiles, velocities and amplitudes were quantified. ICC pathways were theoretically evaluated in a bidomain model. Extracellular potentials were modelled as a function of membrane potentials. Key Results High-velocity, high-amplitude activation was only recorded in the pacemaker region when circumferential conduction occurred. Circumferential propagation accompanied dysrhythmia in 8/8 experiments, was faster than longitudinal propagation (8.9 vs 6.9 mm/s; p=0.004), and of higher amplitude (739 vs 528 μV; p=0.007). Simulations predicted that ICC-MP could be the driving network during longitudinal propagation, whereas during ectopic pacemaking, ICC-IM could outpace and activate ICC-MP in the circumferential axis. Experimental and modeling data demonstrated a linear relationship between velocities and amplitudes (p<0.001). Conclusions & Inferences The high-velocity and high-amplitude profile of the normal pacemaker region is due to localized circumferential propagation. Rapid circumferential propagation also emerges during a range of gastric dysrhythmias, elevating extracellular amplitudes and organizing transverse wavefronts. One possible explanation for these findings is bidirectional coupling between ICC-MP and circular
A mechanical analysis of conduit arteries accounting for longitudinal residual strains.
Wang, Ruoya; Gleason, Rudolph L
2010-04-01
Identification of an appropriate stress-free reference configuration is critically important in providing a reasonable prediction of the intramural stress distribution when performing biomechanical analyses on arteries. The stress-free state is commonly approximated as a radially cut ring that typically opens into a nearly circular sector, relieving much of the circumferential residual strains that exist in the traction-free configuration. An opening angle is often used to characterize this sector. In this study, we first present experimental results showing significant residual deformations in the longitudinal direction of two commonly studied arteries in the pig: the common carotid artery and the left anterior descending coronary artery. We concluded that a radially cut ring cannot completely describe the stress-free state of the arteries. Instead, we propose the use of a longitudinal opening angle, in conjunction with the traditional circumferential opening angle, to experimentally quantify the stress-free state of an artery. Secondly, we propose a new kinematic model to account for the addition of longitudinal residual strains through employing the longitudinal opening angle and performed a stress analysis. We found that with the inclusion of longitudinal residual strains in the stress analysis, the predicted circumferential stress gradient was decreased by 3-fold and the predicted longitudinal stress gradient was increased by 5.7-fold. Thus, inclusion of longitudinal residual strains has a significant effect on the predicted stress distribution in arteries.
Gomes, Victor Augusto M; Alves, Gabriel F; Hadlich, Marcelo; Azevedo, Clerio F; Pereira, Iane M; Santos, Carla Renata F; Brasil, Pedro Emmanuel A A; Sangenis, Luiz Henrique C; Cunha, Ademir B; Xavier, Sergio S; Saraiva, Roberto M
2016-07-01
Chagas heart disease has a high socioeconomic burden, and any strategy to detect early myocardial damage is welcome. Speckle-tracking echocardiography assesses global and segmental left ventricular (LV) systolic function, yielding values of two-dimensional strain (ε). The aim of this study was to determine if patients with chronic Chagas disease and normal LV ejection fractions present abnormalities in global and segmental LV ε. In this prospective study, patients with Chagas disease with no evidence of cardiac involvement (group I; n = 83) or at stage A of the cardiac form (i.e., with changes limited to the electrocardiogram) (group A; n = 42) and 43 control subjects (group C) underwent evaluation of global and segmental LV ε by speckle-tracking echocardiography. A subset of randomly selected patients in group A underwent cardiac magnetic resonance imaging and repeated echocardiography 3.5 ± 0.8 years after the first evaluation. Mean age, chamber dimensions, and LV ejection fraction were similar among the groups. Global longitudinal (group C, -19 ± 2%; group I, -19 ± 2%; group A, -19 ± 2%), circumferential (group C, -19 ± 3%; group I, -20 ± 3%; group A, -19 ± 3%), and radial (group C, 46 ± 10%; group I, 45 ± 13%; group A, 42 ± 14%) LV ε were similar among the groups. Segmental longitudinal, circumferential, and radial LV ε were similar across the studied groups. Seven of 14 patients had areas of fibrosis on cardiac magnetic resonance imaging. Patients with fibrosis had lower global longitudinal (-15 ± 2% vs -18 ± 2%, P = .004), circumferential (-14 ± 2% vs -19 ± 2%, P = .002), and radial LV ε (36 ± 13% vs 54 ± 12%, P = .02) than those without cardiac fibrosis despite similar LV ejection fractions. Patients with fibrosis had lower radial LV ε in the basal inferoseptal wall than patients without cardiac fibrosis (27 ± 17% vs 60 ± 15%, P = .04). Patients with chronic Chagas disease and normal
Aerodynamic Inner Workings of Circumferential Grooves in a Transonic Axial Compressor
NASA Technical Reports Server (NTRS)
Hah, Chunill; Mueller, Martin; Schiffer, Heinz-Peter
2007-01-01
The current paper reports on investigations of the fundamental flow mechanisms of circumferential grooves applied to a transonic axial compressor. Experimental results show that the compressor stall margin is significantly improved with the current set of circumferential grooves. The primary focus of the current investigation is to advance understanding of basic flow mechanics behind the observed improvement of stall margin. Experimental data and numerical simulations of a circumferential groove were analyzed in detail to unlock the inner workings of the circumferential grooves in the current transonic compressor rotor. A short length scale stall inception occurs when a large flow blockage is built on the pressure side of the blade near the leading edge and incoming flow spills over to the adjacent blade passage due to this blockage. The current study reveals that a large portion of this blockage is created by the tip clearance flow originating from 20% to 50% chord of the blade from the leading edge. Tip clearance flows originating from the leading edge up to 20% chord form a tip clearance core vortex and this tip clearance core vortex travels radially inward. The tip clearance flows originating from 20% to 50% chord travels over this tip clearance core vortex and reaches to the pressure side. This part of tip clearance flow is of low momentum as it is coming from the casing boundary layer and the blade suction surface boundary layer. The circumferential grooves disturb this part of the tip clearance flow close to the casing. Consequently the buildup of the induced vortex and the blockage near the pressure side of the passage is reduced. This is the main mechanism of the circumferential grooves that delays the formation of blockage near the pressure side of the passage and delays the onset of short length scale stall inception. The primary effect of the circumferential grooves is preventing local blockage near the pressure side of the blade leading edge that
Numerical investigation of a centrifugal compressor with circumferential grooves in vane diffuser
NASA Astrophysics Data System (ADS)
Chen, X. F.; Qin, G. L.; Ai, Z. J.
2015-08-01
Enhancing stall and surge margin has a great importance for the development of turbo compressors. The application of casing treatment is an effective measure to expand the stall margin and stable operation range. Numerical investigations were conducted to predict the performance of a low flow rate centrifugal compressor with circumferential groove casing treatment in vane diffuser. Numerical cases with different radial location, radial width and axial depth of a circumferential single groove and different numbers of circumferential grooves were carried out to compare the results. The CFD analyses results show that the centrifugal compressor with circumferential grooves in diffuser can extend stable range by about 9% while the efficiency over the whole operating range decreases by 0.2 to 1.7%. The evaluation based on stall margin improvement showed the optimal position for the groove to be located was indicated to exist near the leading edge of the diffuser, and a combination of position, width, depth and numbers of circumferential grooves that will maximize both surge margin range and efficiency.
Demonstration of a Large-Scale Tank Assembly Via Circumferential Friction Stir Welds
NASA Technical Reports Server (NTRS)
Jones, Chip; Adams, Glynn; Colligan, Kevin; McCool, A. (Technical Monitor)
2000-01-01
Five (5) each 14-foot diameter circumferential FSWelds were conducted on the modified CWT, two (2) each pathfinder and three (3) each assembly welds Tapered circumferential welds were successfully demonstrated The use of a closeout anvil was successfully demonstrated during one of the pathfinder welds Considerable difficulty maintaining joint f it-up during the weld process Anvil deflections Hardware dimensional tolerances Inadequate clamping Variations in the heat sink characteristics of the circumferential anvil as compared to the test panel anvil
Hung, Chung-Lieh; Gonçalves, Alexandra; Shah, Amil M; Cheng, Susan; Kitzman, Dalane; Solomon, Scott D
2017-01-01
Advanced age is related to left ventricular (LV) remodeling. We sought to investigate the relationships between aging, elevated hemodynamic load, cardiac mechanics, and LV remodeling in an elderly community-based population. We studied 1105 subjects (76±5 years, 61% women) without prevalent heart failure, who attended the visit 5 of the ARIC study (Atherosclerosis Risk in Communities). LV global longitudinal strain, global circumferential strain, and torsion indices were analyzed using 3-dimensional echocardiography. Advanced age was associated with greater LV concentricity, lower myocardial diastolic relaxation, reduced global longitudinal strain (adjusted estimate, 0.39±0.19% (SE)/decade; P=0.038), borderline greater global circumferential strain (adjusted estimate, -0.59±0.36% (SE)/decade; P=0.08), and higher torsion indices (adjusted estimate for torsion, 0.33±0.04° (SE)/decade; P<0.001). In addition, greater concentricity was associated with decreased global longitudinal strain and greater torsion in multivariable models (all P<0.001). Women showed smaller LV cavity size, greater concentricity, lower myocardial relaxation velocity E', though demonstrated greater global longitudinal strain, global circumferential strain, and torsion than men (all P<0.05). Overall, subjects with hypertension and increasing age were more likely to have higher torsion, though the association between advanced age and greater torsion was more pronounced in women than in men (both interaction P<0.05). In an asymptomatic, senescent community-dwelling population, we observed a distinct, sex-specific pattern of cardiac remodeling. Although we observed worse diastolic and longitudinal function with advanced age or elevated load in both sexes, a significant increase of torsion was more pronounced in women. © 2017 American Heart Association, Inc.
Suever, Jonathan D; Wehner, Gregory J; Jing, Linyuan; Powell, David K; Hamlet, Sean M; Grabau, Jonathan D; Mojsejenko, Dimitri; Andres, Kristin N; Haggerty, Christopher M; Fornwalt, Brandon K
2017-01-01
Mechanics of the left ventricle (LV) are important indicators of cardiac function. The role of right ventricular (RV) mechanics is largely unknown due to the technical limitations of imaging its thin wall and complex geometry and motion. By combining 3D Displacement Encoding with Stimulated Echoes (DENSE) with a post-processing pipeline that includes a local coordinate system, it is possible to quantify RV strain, torsion, and synchrony. In this study, we sought to characterize RV mechanics in 50 healthy individuals and compare these values to their LV counterparts. For each cardiac frame, 3D displacements were fit to continuous and differentiable radial basis functions, allowing for the computation of the 3D Cartesian Lagrangian strain tensor at any myocardial point. The geometry of the RV was extracted via a surface fit to manually delineated endocardial contours. Throughout the RV, a local coordinate system was used to transform from a Cartesian strain tensor to a polar strain tensor. It was then possible to compute peak RV torsion as well as peak longitudinal and circumferential strain. A comparable analysis was performed for the LV. Dyssynchrony was computed from the standard deviation of regional activation times. Global circumferential strain was comparable between the RV and LV (−18.0% for both) while longitudinal strain was greater in the RV (−18.1% vs. −15.7%). RV torsion was comparable to LV torsion (6.2 vs. 7.1 degrees, respectively). Regional activation times indicated that the RV contracted later but more synchronously than the LV. 3D spiral cine DENSE combined with a post–processing pipeline that includes a local coordinate system can resolve both the complex geometry and 3D motion of the RV. PMID:28055859
Global Existence Results for Viscoplasticity at Finite Strain
NASA Astrophysics Data System (ADS)
Mielke, Alexander; Rossi, Riccarda; Savaré, Giuseppe
2018-01-01
We study a model for rate-dependent gradient plasticity at finite strain based on the multiplicative decomposition of the strain tensor, and investigate the existence of global-in-time solutions to the related PDE system. We reveal its underlying structure as a generalized gradient system, where the driving energy functional is highly nonconvex and features the geometric nonlinearities related to finite-strain elasticity as well as the multiplicative decomposition of finite-strain plasticity. Moreover, the dissipation potential depends on the left-invariant plastic rate, and thus depends on the plastic state variable. The existence theory is developed for a class of abstract, nonsmooth, and nonconvex gradient systems, for which we introduce suitable notions of solutions, namely energy-dissipation-balance and energy-dissipation-inequality solutions. Hence, we resort to the toolbox of the direct method of the calculus of variations to check that the specific energy and dissipation functionals for our viscoplastic models comply with the conditions of the general theory.
A New Global Geodetic Strain Rate Model
NASA Astrophysics Data System (ADS)
Kreemer, C. W.; Klein, E. C.; Blewitt, G.; Shen, Z.; Wang, M.; Chamot-Rooke, N. R.; Rabaute, A.
2012-12-01
As part of the Global Earthquake Model (GEM) effort to improve global seismic hazard models, we present a new global geodetic strain rate model. This model (GSRM v. 2) is a vast improvement on the previous model from 2004 (v. 1.2). The model is still based on a finite-element type approach and has deforming cells in between the assumed rigid plates. While v.1.2 contained ~25,000 deforming cells of 0.6° by 0.5° dimension, the new models contains >136,000 cells of 0.25° by 0.2° dimension. We redefined the geometries of the deforming zones based on the definitions of Bird (2003) and Chamot-Rooke and Rabaute (2006). We made some adjustments to the grid geometry at places where seismicity and/or GPS velocities suggested the presence of deforming areas where those previous studies did not. As a result, some plates/blocks identified by Bird (2003) we assumed to deform, and the total number of plates and blocks in GSRM v.2 is 38 (including the Bering block, which Bird (2003) did not consider). GSRM v.1.2 was based on ~5,200 GPS velocities, taken from 86 studies. The new model is based on ~17,000 GPS velocities, taken from 170 studies. The GPS velocity field consists of a 1) ~4900 velocities derived by us for CPS stations publicly available RINEX data and >3.5 years of data, 2) ~1200 velocities for China from a new analysis of all CMONOC data, and 3) velocities published in the literature or made otherwise available to us. All studies were combined into the same reference frame by a 6-parameter transformation using velocities at collocated stations. Because the goal of the project is to model the interseismic strain rate field, we model co-seismic jumps while estimating velocities, ignore periods of post-seismic deformation, and exclude time-series that reflect magmatic and anthropogenic activity. GPS velocities were used to estimate angular velocities for most of the 38 rigid plates and blocks (the rest being taken from the literature), and these were used as boundary
Self-Reacting Friction Stir Welding for Aluminum Alloy Circumferential Weld Applications
NASA Technical Reports Server (NTRS)
Bjorkman, Gerry; Cantrell, Mark; Carter, Robert
2003-01-01
Friction stir welding is an innovative weld process that continues to grow in use, in the commercial, defense, and space sectors. It produces high quality and high strength welds in aluminum alloys. The process consists of a rotating weld pin tool that plasticizes material through friction. The plasticized material is welded by applying a high weld forge force through the weld pin tool against the material during pin tool rotation. The high weld forge force is reacted against an anvil and a stout tool structure. A variation of friction stir welding currently being evaluated is self-reacting friction stir welding. Self-reacting friction stir welding incorporates two opposing shoulders on the crown and root sides of the weld joint. In self-reacting friction stir welding, the weld forge force is reacted against the crown shoulder portion of the weld pin tool by the root shoulder. This eliminates the need for a stout tooling structure to react the high weld forge force required in the typical friction stir weld process. Therefore, the self-reacting feature reduces tooling requirements and, therefore, process implementation costs. This makes the process attractive for aluminum alloy circumferential weld applications. To evaluate the application of self-reacting friction stir welding for aluminum alloy circumferential welding, a feasibility study was performed. The study consisted of performing a fourteen-foot diameter aluminum alloy circumferential demonstration weld using typical fusion weld tooling. To accomplish the demonstration weld, weld and tack weld development were performed and fourteen-foot diameter rings were fabricated. Weld development consisted of weld pin tool selection and the generation of a process map and envelope. Tack weld development evaluated gas tungsten arc welding and friction stir welding for tack welding rings together for circumferential welding. As a result of the study, a successful circumferential demonstration weld was produced leading
Mechanical Strain Promotes Oligodendrocyte Differentiation by Global Changes of Gene Expression
Jagielska, Anna; Lowe, Alexis L.; Makhija, Ekta; Wroblewska, Liliana; Guck, Jochen; Franklin, Robin J. M.; Shivashankar, G. V.; Van Vliet, Krystyn J.
2017-01-01
Differentiation of oligodendrocyte progenitor cells (OPC) to oligodendrocytes and subsequent axon myelination are critical steps in vertebrate central nervous system (CNS) development and regeneration. Growing evidence supports the significance of mechanical factors in oligodendrocyte biology. Here, we explore the effect of mechanical strains within physiological range on OPC proliferation and differentiation, and strain-associated changes in chromatin structure, epigenetics, and gene expression. Sustained tensile strain of 10–15% inhibited OPC proliferation and promoted differentiation into oligodendrocytes. This response to strain required specific interactions of OPCs with extracellular matrix ligands. Applied strain induced changes in nuclear shape, chromatin organization, and resulted in enhanced histone deacetylation, consistent with increased oligodendrocyte differentiation. This response was concurrent with increased mRNA levels of the epigenetic modifier histone deacetylase Hdac11. Inhibition of HDAC proteins eliminated the strain-mediated increase of OPC differentiation, demonstrating a role of HDACs in mechanotransduction of strain to chromatin. RNA sequencing revealed global changes in gene expression associated with strain. Specifically, expression of multiple genes associated with oligodendrocyte differentiation and axon-oligodendrocyte interactions was increased, including cell surface ligands (Ncam, ephrins), cyto- and nucleo-skeleton genes (Fyn, actinins, myosin, nesprin, Sun1), transcription factors (Sox10, Zfp191, Nkx2.2), and myelin genes (Cnp, Plp, Mag). These findings show how mechanical strain can be transmitted to the nucleus to promote oligodendrocyte differentiation, and identify the global landscape of signaling pathways involved in mechanotransduction. These data provide a source of potential new therapeutic avenues to enhance OPC differentiation in vivo. PMID:28473753
Demonstration of a Large-Scale Tank Assembly via Circumferential Friction Stir Welds
NASA Technical Reports Server (NTRS)
Jones, Clyde S.; Adams, Glynn; Colligan, Kevin
2000-01-01
A collaborative effort between NASA/Marshall Space Flight Center and the Michoud Unit of Lockheed Martin Space Systems Company was undertaken to demonstrate assembly of a large-scale aluminum tank using circumferential friction stir welds. The hardware used to complete this demonstration was fabricated as a study of near-net- shape technologies. The tooling used to complete this demonstration was originally designed for assembly of a tank using fusion weld processes. This presentation describes the modifications and additions that were made to the existing fusion welding tools required to accommodate circumferential friction stir welding, as well as the process used to assemble the tank. The tooling modifications include design, fabrication and installation of several components. The most significant components include a friction stir weld unit with adjustable pin length capabilities, a continuous internal anvil for 'open' circumferential welds, a continuous closeout anvil, clamping systems, an external reaction system and the control system required to conduct the friction stir welds and integrate the operation of the tool. The demonstration was intended as a development task. The experience gained during each circumferential weld was applied to improve subsequent welds. Both constant and tapered thickness 14-foot diameter circumferential welds were successfully demonstrated.
A New Global Geodetic Strain Rate Model
NASA Astrophysics Data System (ADS)
Kreemer, C.; Blewitt, G.; Klein, E. C.; Shen, Z.; Wang, M.; Estey, L.; Wier, S.
2013-12-01
As part of the Global Earthquake Model (GEM) effort to improve global seismic hazard models, we present a new global geodetic strain rate model. This model (GSRM v. 2) is a vast improvement on the previous model from 2004 (v. 1.2). The model is still based on a finite-element type approach and has deforming cells in between the assumed rigid plates. The new model contains ~144,700 cells of 0.25° by 0.2° dimension. We redefined the geometries of the deforming zones based on the definitions of Bird (2003) and Chamot-Rooke and Rabaute (2006). We made some adjustments to the grid geometry at places where seismicity and/or GPS velocities suggested either the presence of deforming areas or a rigid block where those previous studies did not. GSRM v.2 includes 50 plates and blocks, including many not considered by Bird (2003). The new GSRM model is based on over 20,700 horizontal geodetic velocities at over 17,000 unique locations. The GPS velocity field consists of a 1) Over 6500 velocities derived by the University of Nevada, Reno, for CGPS stations for which >2.5 years of RINEX data are available until April 2013, 2) ~1200 velocities for China from a new analysis of all data from the Crustal Movement Network of China (CMONOC), and 3) about 13,000 velocities from 212 studies published in the literature or made otherwise available to us. Velocities from all studies were combined into the same reference frame by a 6-parameter transformation using velocities at collocated stations. We model co-seismic jumps while estimating velocities, ignore periods of post-seismic deformation, and exclude time-series that reflect magmatic and anthropogenic activity. GPS velocities were used to estimate angular velocities for 36 of the 50 rigid plates and blocks (the rest being taken from the literature), and these were used as boundary conditions in the strain rate calculations. For the strain rate calculations we used the method of Haines and Holt. In order to fit the data equally well
Emren, Sadik Volkan; Tuluce, Selcen Yakar; Levent, Fatih; Tuluce, Kamil; Kalkan, Toygar; Yildiz, Yasar; Alacacioğlu, Ahmet; Kucukzeybek, Yüksel; Akyol, Murat; Salman, Tarık
2015-12-01
Trastuzumab, a chemotherapeutic agent used in the treatment of breast cancer. has been shown to induce subclinical left ventricular (LV) dysfunction during a three to six month period as evidenced by strain echocardiographic examination without any change occurring in the ejection fraction of LV. The present study evaluated the presence of subclinical LV dysfunction using strain echocardiography 1 day and 7 days after the initiation of trastuzumab therapy. The patients with breast cancer receiving adjuvant trastuzumab therapy underwent 2-dimensional, tissue Doppler, and strain echocardiographic examination at baseline and 1 day and 7 days after therapy. LV global longitudinal strain (GLS), global circumferential strain (GCS) values, and other echocardiographic parameters were calculated. A total of 40 females, mean age 50+/-10 years, were evaluated. Of these patients, 97% received anthracycline and 73% received radiotherapy before the initiation of trastuzumab therapy. No change was observed in any of the echocardiographic parameters 1 day after the initiation of trastuzumab therapy (p>0.05). The LV ejection fraction, tissue Doppler parameters, and GCS values did not show any changes 7 days after the initiation of therapy, whereas significant decreases were observed in GLS value (19.2+/-4.0% vs. 17.2+/-3.4, p=0.001) and systolic annular velocity of the lateral LV wall (S' velocity) (10.5+/-3.2 vs. 8.6+/-2.2, p=0.002). Trastuzumab therapy is associated with subclinical LV dysfunction as early as 7 days after initiation of the therapy as evidenced by the decreases in GLS value of LV and systolic annular velocity of the lateral LV wall.
Cardiac biplane strain imaging: initial in vivo experience
NASA Astrophysics Data System (ADS)
Lopata, R. G. P.; Nillesen, M. M.; Verrijp, C. N.; Singh, S. K.; Lammens, M. M. Y.; van der Laak, J. A. W. M.; van Wetten, H. B.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.
2010-02-01
In this study, first we propose a biplane strain imaging method using a commercial ultrasound system, yielding estimation of the strain in three orthogonal directions. Secondly, an animal model of a child's heart was introduced that is suitable to simulate congenital heart disease and was used to test the method in vivo. The proposed approach can serve as a framework to monitor the development of cardiac hypertrophy and fibrosis. A 2D strain estimation technique using radio frequency (RF) ultrasound data was applied. Biplane image acquisition was performed at a relatively low frame rate (<100 Hz) using a commercial platform with an RF interface. For testing the method in vivo, biplane image sequences of the heart were recorded during the cardiac cycle in four dogs with an aortic stenosis. Initial results reveal the feasibility of measuring large radial, circumferential and longitudinal cumulative strain (up to 70%) at a frame rate of 100 Hz. Mean radial strain curves of a manually segmented region-of-interest in the infero-lateral wall show excellent correlation between the measured strain curves acquired in two perpendicular planes. Furthermore, the results show the feasibility and reproducibility of assessing radial, circumferential and longitudinal strains simultaneously. In this preliminary study, three beagles developed an elevated pressure gradient over the aortic valve (Δp: 100-200 mmHg) and myocardial hypertrophy. One dog did not develop any sign of hypertrophy (Δp = 20 mmHg). Initial strain (rate) results showed that the maximum strain (rate) decreased with increasing valvular stenosis (-50%), which is in accordance with previous studies. Histological findings corroborated these results and showed an increase in fibrotic tissue for the hearts with larger pressure gradients (100, 200 mmHg), as well as lower strain and strain rate values.
Structural and leakage integrity of tubes affected by circumferential cracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernalsteen, P.
1997-02-01
In this paper the author deals with the notion that circumferential cracks are generally considered unacceptable. He argues for the need to differentiate two facets of such cracks: the issue of the size and growth rate of a crack; and the issue of the structural strength and leakage potential of the tube in the presence of the crack. In this paper the author tries to show that the second point is not a major concern for such cracks. The paper presents data on the structural strength or burst pressure characteristics of steam generator tubes derived from models and data basesmore » of experimental work. He also presents a leak rate model, and compares the performance of circumferential and axial cracks as far as burst strength and leak rate. The final conclusion is that subject to improvement in NDE capabilities (sizing, detection, growth), that Steam Generator Defect Specific Management can be used to allow circumferentially degraded tubes to remain in service.« less
Ari, Mehmet Emre; Ekici, Filiz; Çetin, İbrahim İlker; Tavil, Emine Betül; Yaralı, Neşe; Işık, Pamir; Hazırolan, Tuncay; Tunç, Bahattin
2017-03-01
The purpose of this study is to determine early myocardial dysfunction in β-thalassemia major (BTM) patients. Where the myocardial dysfunction cannot be detected by conventional echocardiography, it could be detected by tissue Doppler imaging (TDI) or speckle tracking echocardiography (STE). In this study, we analyzed 60 individuals, 30 of whom were BTM patients and the other 30 of whom were the control group. T2* magnetic resonance imaging (MRI) was used to measure cardiac iron deposition. The myocardial functions were evaluated by conventional echocardiography, TDI and STE. When basal lateral left ventricular and basal septal wall TDI values were compared between the patient group and control group, only isovolumic contraction time values were significantly longer in the patients. The global circumferential strain was significantly lower in the patients. When evaluated as segmental, longitudinal strain values of basal inferoseptum and circumferential strain values of anteroseptum, anterior, and inferolateral segments were significantly lower in the patients. In the patients, global longitudinal and circumferential strains in the group who had pathological T2* values were significantly lower than the group who did not. In addition, circumferential strain values in anteroseptum, anterolateral, inferior, and inferoseptum segments were significantly lower in the patients with T2* values<20 ms than those with T2* values≥20 ms. Although T2* MRI is the most sensitive test detecting myocardial iron load, TDI and STE can be used for screening myocardial dysfunction. The abnormal strain values, especially circumferential, may be detected as the first finding of abnormal iron load and related to T2* values. © 2017, Wiley Periodicals, Inc.
Circumferential gap propagation in an anisotropic elastic bacterial sacculus
NASA Astrophysics Data System (ADS)
Taneja, Swadhin; Levitan, Benjamin A.; Rutenberg, Andrew D.
2014-01-01
We have modeled stress concentration around small gaps in anisotropic elastic sheets, corresponding to the peptidoglycan sacculus of bacterial cells, under loading corresponding to the effects of turgor pressure in rod-shaped bacteria. We find that under normal conditions the stress concentration is insufficient to mechanically rupture bacteria, even for gaps up to a micron in length. We then explored the effects of stress-dependent smart autolysins, as hypothesized by A. L. Koch [Adv. Microb. Physiol. 24, 301 (1983), 10.1016/S0065-2911(08)60388-4; Res. Microbiol. 141, 529 (1990), 10.1016/0923-2508(90)90017-K]. We show that the measured anisotropic elasticity of the peptidoglycan (PG) sacculus can lead to stable circumferential propagation of small gaps in the sacculus. This is consistent with the recent observation of circumferential propagation of PG-associated MreB patches in rod-shaped bacteria. We also find a bistable regime of both circumferential and axial gap propagation, which agrees with behavior reported in cytoskeletal mutants of B. subtilis. We conclude that the elastic anisotropies of a bacterial sacculus, as characterized experimentally, may be relevant for maintaining rod-shaped bacterial growth.
Huang, He; Jing, Xian-chao; Hu, Zhang-xue; Chen, Xi; Liu, Xiao-qin
2015-12-01
To observe the ventricular global and regional function of the patients with systemic amyloidosis using two-dimensional speckle tracking echocardiography. The study enrolled 31 consecutive biopsy-proved patients with systemic amyloidosis who underwent echocardiographic examination and EF ≥ 55% and 37 age- and gender-matched healthy controls. We compared systolic strain and strain rate, diastolic strain rate, time to peak strain, peak delay time in longitudinal, radial, circumferential directions in 16 left ventricular segments. The global peak systolic longitudinal and radial strain of left ventricle, peak systolic longitudinal strain and strain rate, diastolic strain rate of right ventricular free wall were also compared. (1) Global peak systolic longitudinal strain (GPSLS), peak systolic longitudinal strain (PSLS) and strain rate (PSLSR), peak early diastolic longitudinal strain rate (PELSR) in 16 segments were decreased in case (P < 0.05). (2) Peak systolic radial strain and strain rate of inferoseptum and inferolateral at the level of papillary muscle were lower (P < 0.05), and peak early diastolic radial strain rate (PERSR) was reduced (P < 0.05). (3) Peak early diastolic circumferential strain rate was lower (P < 0.05). (4) Time to peak systolic longitudinal, radial, circumferential strain was longer, and peak delay time at the same level retarded (P < 0.05). (5) Into right ventricular wall, PSLS and PSLSR at mid-segment, and PSLSR, PELSR, peak atrial systolic longitudinal strain rate (PALSR) at basal were reduced (P < 0.05). (6) Inverse correlation between interventricular septum (IVS) thickness and GPSLS and GPSRS was found (P < 0.05). Systolic and diastolic dysfunction existed in systemic amyloidosis with preserved EF. Mechanical contraction disorder may be one reason for systolic dysfunction. GPLSR and GPRSR were negatively related to IVS thickness. © 2015, Wiley Periodicals, Inc.
Left Ventricular Strain in Chemotherapy-Naive and Radiotherapy-Naive Patients With Cancer.
Tadic, Marijana; Genger, Martin; Baudisch, Ana; Kelle, Sebastian; Cuspidi, Cesare; Belyavskiy, Evgeny; Burkhardt, Franziska; Venneri, Lucia; Attanasio, Philipp; Pieske, Burkert
2018-03-01
We sought to investigate left ventricular (LV) function and mechanics in patients with cancer before they received chemotherapy or radiotherapy, as well as the relationship between cancer and reduced LV multidirectional strain in the whole study population. The retrospective study involved 122 chemotherapy- and radiotherapy-naive patients with cancer and 45 age- and sex-matched controls with a cardiovascular risk profile similar to that of the patients with cancer. All the patients underwent echocardiographic examination before introduction of chemotherapy or radiotherapy. LV longitudinal (-19.1% ± 2.1% vs -17.8% ± 3.5%; P = 0.022), circumferential (-22.9% ± 3.5% vs -20.1% ± 4.1%; P < 0.001), and radial (40.5% ± 8.8% vs 35.2% ± 10.7%; P = 0.004) strain was significantly lower in the patients with cancer than in the control group. Endocardial and midmyocardial longitudinal LV strain was significantly reduced in the patients with cancer compared with the controls, whereas epicardial longitudinal strain was similar between these groups. Endocardial, midmyocardial, and epicardial circumferential strain was significantly lower in the chemotherapy- or radiotherapy-naive patients with cancer than in the controls. Cancer was associated with reduced longitudinal (odds ratio [OR], 9.0; 95% confidence interval [CI], 2.20-23.50; P < 0.001), reduced circumferential (OR, 7.1; 95% CI, 3.80-20.40; P < 0.001), and reduced radial strain (OR, 7.2; 95% CI, 3.41-25.10; P < 0.001) independent of age, sex, body mass index, diabetes, and hypertension. LV mechanics was impaired in the patients with cancer compared with the controls even before initiation of chemotherapy and radiotherapy. Cancer and hypertension were associated with reduced LV multidirectional strain independent of other clinical parameters. The present results indicate that cancer itself potentially induces cardiac remodelling independent of chemotherapy and radiotherapy. Copyright © 2017 Canadian
Peteiro, Jesus; Bouzas-Mosquera, Alberto; Broullon, Javier; Sanchez-Fernandez, Gabriel; Barbeito, Cayetana; Perez-Cebey, Lucia; Martinez, Dolores; Vazquez-Rodriguez, Jose M
2017-01-01
LV torsion during exercise in patients with coronary artery disease (CAD) is not well known. Circumferential strain (CS) and left ventricular (LV) torsion (Tor) have not been evaluated during ischemia in these patients. We aimed to assess the effect of ischemia during exercise echocardiography (ExE) on CS and Tor. We studied a group of 73 patients with true positive ExE results (Ischemic group: ischemia plus an abnormal coronary angiogram) and a matched control group of 66 patients with negative ExE and either normal coronary angiography or low post-test probability of CAD. Basal rotation (Rot) and apical rotation and basal and apical CS were studied by speckle tracking at rest and exercise. Apical CS and apical and basal Rot values were similar between groups at rest, except basal CS which was already worse in the ischemic group. At exercise, all rotational and CS parameters were impaired in the ischemic in comparison with the control group (basal CS: -18 ± 5 vs. -25 ± 7 %, p < 0.001; apical CS: -31 ± 11 vs. - 43 ± 9 %, p < 0.001; time to basal CS: 52 ± 6 vs. 48 ± 7 %, p = 0.001; time to apical CS: 55 ± 7 vs. 49 ± 6 %, p < 0.001; basal rotation: -0.7 ± 6.5° vs. -6.2 ± 8.5°, p < 0.001; LV twist 13.0 ± 10.4° vs.19.7 ± 11.5°, p < 0.001; LV-Tor 1.9 ± 1.6°/cm vs. 2.8 ± 1.7˚/cm, p = 0.001) with the exception of apical rotation which was similar (12.3 ± 7.4° vs. 13.4 ± 7.7°, p = NS). Basal and apical CS and basal rotation impair during exercise-induced ischemia. LV-Tor decreases with ischemia due to worsening of basal rotation, whereas apical rotation does not impair, suggesting the existence of an apical compensatory mechanism.
Molecular Modeling of the Axial and Circumferential Elastic Moduli of Tubulin
Zeiger, A. S.; Layton, B. E.
2008-01-01
Microtubules play a number of important mechanical roles in almost all cell types in nearly all major phylogenetic trees. We have used a molecular mechanics approach to perform tensile tests on individual tubulin monomers and determined values for the axial and circumferential moduli for all currently known complete sequences. The axial elastic moduli, in vacuo, were found to be 1.25 GPa and 1.34 GPa for α- and β-bovine tubulin monomers. In the circumferential direction, these moduli were 378 MPa for α- and 460 MPa for β-structures. Using bovine tubulin as a template, 269 homologous tubulin structures were also subjected to simulated tensile loads yielding an average axial elastic modulus of 1.10 ± 0.14 GPa for α-tubulin structures and 1.39 ± 0.68 GPa for β-tubulin. Circumferentially the α- and β-moduli were 936 ± 216 MPa and 658 ± 134 MPa, respectively. Our primary finding is that that the axial elastic modulus of tubulin diminishes as the length of the monomer increases. However, in the circumferential direction, no correlation exists. These predicted anisotropies and scale dependencies may assist in interpreting the macroscale behavior of microtubules during mitosis or cell growth. Additionally, an intergenomic approach to investigating the mechanical properties of proteins may provide a way to elucidate the evolutionary mechanical constraints imposed by nature upon individual subcellular components. PMID:18621829
Guo, Xiaoya; Zhu, Jian; Maehara, Akiko; Monoly, David; Samady, Habib; Wang, Liang; Billiar, Kristen L.; Zheng, Jie; Yang, Chun; Mintz, Gary S.; Giddens, Don P.; Tang, Dalin
2016-01-01
Computational models have been used to calculate plaque stress and strain for plaque progression and rupture investigations. An intravascular ultrasound (IVUS)-based modeling approach is proposed to quantify in vivo vessel material properties for more accurate stress/strain calculations. In vivo Cine IVUS and VH-IVUS coronary plaque data were acquired from one patient with informed consent obtained. Cine IVUS data and 3D thin-slice models with axial stretch were used to determine patient-specific vessel material properties. Twenty full 3D fluid–structure interaction models with ex vivo and in vivo material properties and various axial and circumferential shrink combinations were constructed to investigate the material stiffness impact on stress/strain calculations. The approximate circumferential Young’s modulus over stretch ratio interval [1.0, 1.1] for an ex vivo human plaque sample and two slices (S6 and S18) from our IVUS data were 1631, 641, and 346 kPa, respectively. Average lumen stress/strain values from models using ex vivo, S6 and S18 materials with 5 % axial shrink and proper circumferential shrink were 72.76, 81.37, 101.84 kPa and 0.0668, 0.1046, and 0.1489, respectively. The average cap strain values from S18 material models were 150–180 % higher than those from the ex vivo material models. The corresponding percentages for the average cap stress values were 50–75 %. Dropping axial and circumferential shrink consideration led to stress and strain over-estimations. In vivo vessel material properties may be considerably softer than those from ex vivo data. Material stiffness variations may cause 50–75 % stress and 150–180 % strain variations. PMID:27561649
Global Earthquake Activity Rate models based on version 2 of the Global Strain Rate Map
NASA Astrophysics Data System (ADS)
Bird, P.; Kreemer, C.; Kagan, Y. Y.; Jackson, D. D.
2013-12-01
Global Earthquake Activity Rate (GEAR) models have usually been based on either relative tectonic motion (fault slip rates and/or distributed strain rates), or on smoothing of seismic catalogs. However, a hybrid approach appears to perform better than either parent, at least in some retrospective tests. First, we construct a Tectonic ('T') forecast of shallow (≤ 70 km) seismicity based on global plate-boundary strain rates from version 2 of the Global Strain Rate Map. Our approach is the SHIFT (Seismic Hazard Inferred From Tectonics) method described by Bird et al. [2010, SRL], in which the character of the strain rate tensor (thrusting and/or strike-slip and/or normal) is used to select the most comparable type of plate boundary for calibration of the coupled seismogenic lithosphere thickness and corner magnitude. One difference is that activity of offshore plate boundaries is spatially smoothed using empirical half-widths [Bird & Kagan, 2004, BSSA] before conversion to seismicity. Another is that the velocity-dependence of coupling in subduction and continental-convergent boundaries [Bird et al., 2009, BSSA] is incorporated. Another forecast component is the smoothed-seismicity ('S') forecast model of [Kagan & Jackson, 1994, JGR; Kagan & Jackson, 2010, GJI], which was based on optimized smoothing of the shallow part of the GCMT catalog, years 1977-2004. Both forecasts were prepared for threshold magnitude 5.767. Then, we create hybrid forecasts by one of 3 methods: (a) taking the greater of S or T; (b) simple weighted-average of S and T; or (c) log of the forecast rate is a weighted average of the logs of S and T. In methods (b) and (c) there is one free parameter, which is the fractional contribution from S. All hybrid forecasts are normalized to the same global rate. Pseudo-prospective tests for 2005-2012 (using versions of S and T calibrated on years 1977-2004) show that many hybrid models outperform both parents (S and T), and that the optimal weight on S
NASA Technical Reports Server (NTRS)
Delale, F.; Erdogan, F.
1981-01-01
An approximate solution was obtained for a cylindrical shell containing a part-through surface crack. It was assumed that the shell contains a circumferential or axial semi-elliptic internal or external surface crack and was subjected to a uniform membrane loading or a uniform bending moment away from the crack region. A Reissner type theory was used to account for the effects of the transverse shear deformations. The stress intensity factor at the deepest penetration point of the crack was tabulated for bending and membrane loading by varying three dimensionless length parameters of the problem formed from the shell radius, the shell thickness, the crack length, and the crack depth. The upper bounds of the stress intensity factors are provided by the results of the elasticity solution obtained from the axisymmetric crack problem for the circumferential crack, and that found from the plane strain problem for a circular ring having a radial crack for the axial crack. The line-spring model gives the expected results in comparison with the elasticity solutions. Results also compare well with the existing finite element solution of the pressurized cylinder containing an internal semi-elliptic surface crack.
Singh, Gautam K.; Cupps, Brian; Pasque, Michael; Woodard, Pamela K.; Holland, Mark R.; Ludomirsky, Achiau
2013-01-01
Background Myocardial strain is a sensitive measure of ventricular systolic function. Two-dimensional speckle-tracking echocardiography (2DSE) is an angle-independent method for strain measurement but has not been validated in pediatric subjects. We evaluated the accuracy and reproducibility of 2DSE-measured strain against reference tagged MRI-measured strain in pediatric subjects with normal hearts and those with single ventricle (SV) of left ventricle (LV) morphology s/p Fontan procedure. Methods Peak systolic circumferential (CS) and longitudinal (LS) strains in segments (n = 16) of LVs in age and BSA matched 20 healthy and 12 pediatric subjects with tricuspid atresia s/p Fontan procedure were measured by 2DSE and tagged MRI. Average (global) and regional segmental strains measured by two methods were compared using Spearman and Bland-Altman analyses. Results 2DSE and tagged MRI measured global strains demonstrated close agreements, which were better for LS than CS and in normal LVs than in SVs (95% limits of agreement: +0.0% to +3.12%, −2.48 % to +1.08%, −4.6% to +1.8% and −3.6% to +1.8% respectively). There was variability in agreement between regional strains with wider limits in apical than in basal regions in normal LVs and heterogeneous in SVs. The strain values were significantly (p < 0.05) higher in normal LVs than in SVs except for basal LSs, which were similar in both cohorts. The regional strains in normal LVs demonstrated an apico-basal magnitude gradient whereas SVs showed heterogeneity. The reproducibility was the most robust for images obtained with frame rates between 60 and 90 frame/sec; global LS in both cohorts; and basal strains in normal LVs. Conclusions 2DSE-measured strains agree with MRI-measured strain globally but vary regionally particularly in SVs. Global strain may be more robust tool for the cardiac function evaluation than regional strain in SV physiology. The reliability of 2DSE measured strain is affected by the frame rate
Circumferential pressure probe
NASA Technical Reports Server (NTRS)
Holmes, Harlan K. (Inventor); Moore, Thomas C. (Inventor); Fantl, Andrew J. (Inventor)
1989-01-01
A probe for measuring circumferential pressure inside a body cavity is disclosed. In the preferred embodiment, a urodynamic pressure measurement probe for evaluating human urinary sphincter function is disclosed. Along the length of the probe are disposed a multiplicity of deformable wall sensors which typically comprise support tube sections with flexible side wall areas. These are arranged along the length of the probe in two areas, one just proximal to the tip for the sensing of fluid pressure inside the bladder, and five in the sensing section which is positioned within the urethra at the point at which the urinary sphincter constricts to control the flow of urine. The remainder of the length of the probe comprises multiple rigid support tube sections interspersed with flexible support tube sections in the form of bellows to provide flexibility.
Karjalainen, T; He, M; Chong, A K S; Lim, A Y T; Ryhanen, J
2010-07-01
Nickel-titanium (NiTi) has been proposed as an alternative material for flexor tendon core suture. To our knowledge, its suitability as a circumferential suture of flexor tendon repair has not been investigated before. The purpose of this ex vivo study was to investigate the biomechanical properties of NiTi circumferential repairs and to compare them with commonly used polypropylene. Forty porcine flexor tendons were cut and repaired by simple running or interlocking mattress technique using 100 microm NiTi wire or 6-0 polypropylene. The NiTi circumferential repairs showed superior stiffness, gap resistance, and load to failure when compared to polypropylene repairs with both techniques. Nickel-titanium wire seems to be a potential material for circumferential repair of flexor tendons. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Gavara, Jose; Rodriguez-Palomares, Jose F; Valente, Filipa; Monmeneu, Jose V; Lopez-Lereu, Maria P; Bonanad, Clara; Ferreira-Gonzalez, Ignacio; Garcia Del Blanco, Bruno; Rodriguez-Garcia, Julian; Mutuberria, Maria; de Dios, Elena; Rios-Navarro, Cesar; Perez-Sole, Nerea; Racugno, Paolo; Paya, Ana; Minana, Gema; Canoves, Joaquim; Pellicer, Mauricio; Lopez-Fornas, Francisco J; Barrabes, Jose; Evangelista, Arturo; Nunez, Julio; Chorro, Francisco J; Garcia-Dorado, David; Bodi, Vicente
2017-12-08
The aim of this study was to evaluate the prognostic value of strain as assessed by tissue tracking (TT) cardiac magnetic resonance (CMR) soon after ST-segment elevation myocardial infarction (STEMI). The prognostic value of myocardial strain as assessed post-STEMI by TT-CMR is unknown. The authors studied the prognostic value of TT-CMR in 323 patients who underwent CMR 1 week post-STEMI. Global (average of peak segmental values [%]) and segmental (number of altered segments) longitudinal (LS), circumferential, and radial strain were assessed using TT-CMR. Global and segmental strain cutoff values were derived from 32 control patients. CMR-derived left ventricular ejection fraction, microvascular obstruction, and infarct size were determined. Results were validated in an external cohort of 190 STEMI patients. During a median follow-up of 1,085 days, 54 first major adverse cardiac events (MACE), which included 10 cardiac deaths, 25 readmissions for heart failure, and 19 readmissions for reinfarction were documented. MACE was associated with more severe abnormalities in all strain indexes (p < 0.001), although only global LS was an independent predictor (p < 0.001). The MACE rate was higher in patients with a global LS of ≥-11% (22% vs. 9%; p = 0.001). After adjustment for baseline and CMR variables, global LS (hazard ratio [HR]: 1.21; 95% confidence interval [CI]: 1.11 to 1.32; p < 0.001) was associated with MACE. In the external validation cohort, a global LS ≥-11% was seen in a higher proportion of patients with MACE (34% vs. 9%; p < 0.001). Global LS predicted MACE after adjustment for baseline and CMR variables (HR: 1.18; 95% CI: 1.04 to 1.33; p = 0.008). The addition of global LS to the multivariate models, including baseline and CMR variables, did not significantly improve the categorical net reclassification improvement index in either the study group (-0.015; p = 0.7) or in the external validation cohort (-0.019; p = 0.9). TT-CMR provided
Arthroscopic repair of circumferential lesions of the glenoid labrum: surgical technique.
Tokish, John M; McBratney, Colleen M; Solomon, Daniel J; Leclere, Lance; Dewing, Christopher B; Provencher, Matthew T
2010-09-01
Symptomatic pan-labral or circumferential (360°) tears of the glenohumeral labrum are an uncommon injury. The purpose of the present study was to report the results of surgical treatment of circumferential lesions of the glenoid labrum with use of validated outcome instruments. From July 2003 to May 2006, forty-one shoulders in thirty-nine patients (thirty-four men and five women) with a mean age of 25.1 years were prospectively enrolled in a multicenter study and were managed for a circumferential (360°) lesion of the glenoid labrum. All patients had a primary diagnosis of pain and recurrent shoulder instability, and all underwent arthroscopic repair of the circumferential labral tear with a mean of 7.1 suture anchors. The outcomes for thirty-nine of the forty-one shoulders were assessed after a mean duration of follow-up of 31.8 months on the basis of the rating of pain and instability on a scale of 0 to 10, a physical examination, and three outcome instruments (the Single Assessment Numeric Evaluation score, the modified American Shoulder and Elbow Surgeons score, and the Short Form-12 score). Significant improvement was noted in terms of the mean pain score (from 4.3 to 1.1), the mean instability score (from 7.3 to 0.2), the mean modified American Shoulder and Elbow Surgeons score (from 55.5 to 89.6), the mean Short Form-12 score (from 75.7 to 90.0), and the mean Single Assessment Numeric Evaluation score (from 36.7 to 88.5). Six shoulders required revision surgery because of recurrent instability (two), recalcitrant biceps tendinitis (two), or postoperative tightness (two). All patients returned to their preinjury activity level. Pan-labral or circumferential lesions are an uncommon yet extensive injury of the glenohumeral joint that may result in recurrent instability and pain. The present study demonstrates that arthroscopic capsulolabral repair with suture anchor fixation can restore the stability of the glenohumeral joint and can provide a reliable
Interactive Web Interface to the Global Strain Rate Map Project
NASA Astrophysics Data System (ADS)
Meertens, C. M.; Estey, L.; Kreemer, C.; Holt, W.
2004-05-01
An interactive web interface allows users to explore the results of a global strain rate and velocity model and to compare them to other geophysical observations. The most recent model, an updated version of Kreemer et al., 2003, has 25 independent rigid plate-like regions separated by deformable boundaries covered by about 25,000 grid areas. A least-squares fit was made to 4900 geodetic velocities from 79 different geodetic studies. In addition, Quaternary fault slip rate data are used to infer geologic strain rate estimates (currently only for central Asia). Information about the style and direction of expected strain rate is inferred from the principal axes of the seismic strain rate field. The current model, as well as source data, references and an interactive map tool, are located at the International Lithosphere Program (ILP) "A Global Strain Rate Map (ILP II-8)" project website: http://www-world-strain-map.org. The purpose of the ILP GSRM project is to provide new information from this, and other investigations, that will contribute to a better understanding of continental dynamics and to the quantification of seismic hazards. A unique aspect of the GSRM interactive Java map tool is that the user can zoom in and make custom views of the model grid and results for any area of the globe selecting strain rate and style contour plots and principal axes, observed and model velocity fields in specified frames of reference, and geologic fault data. The results can be displayed with other data sets such Harvard CMT earthquake focal mechanisms, stress directions from the ILP World Stress Map Project, and topography. With the GSRM Java map tool, the user views custom maps generated by a Generic Mapping Tool (GMT) server. These interactive capabilities greatly extend what is possible to present in a published paper. A JavaScript version, using pre-constructed maps, as well as a related information site have also been created for broader education and outreach access
Optimization of the axial compressor flow passage to reduce the circumferential distortion
NASA Astrophysics Data System (ADS)
Popov, G.; Kolmakova, D.; Shklovets, A.; Ermakov, A.
2015-08-01
This work is motivated by the necessity to reduce the effects of the flow circumferential distortion in the flow passage of the aircraft gas turbine engine (GTE). In previous research, the authors have proposed the approaches to decrease of the flow circumferential distortion arising from the mid-support racks of GTE compressor and having a negative impact on the blade rows, located upstream. In particular, the idea of introducing the circumferentially non-uniform blade pitch and profile stagger angle of guide vanes located in front of the support was contributed in order to redistribute the flow and decrease the dynamic stresses in the rotor wheel of the same stage. During the research presented in this paper, another principal of reduction of the flow circumferential distortion was chosen. Firstly, the variants of upgrading the existing support racks were found. Secondly, the new design of support was offered. Both the first and the second version of the support design variation took into account the availability of technological and structural limitations associated with the location of oil pipes, springs and others elements in the support racks. Investigations of modified design showed that the support with altered racks provides a reduction of dynamic stresses by 20% at resonance with the most dangerous harmonic, and the new design of support can give the decrease of 30%.
NASA Astrophysics Data System (ADS)
Peterson, G. A.; Johnson, C. L.; Byrne, P. K.; Phillips, R. J.
2018-05-01
Wrinkle ridges within volcanic plains on Mercury host just as much shortening strain as lobate scarps and high relief ridges, suggesting that wrinkle ridges have accommodated much more strain from global contraction than previously thought.
Macione, J; Depaula, C A; Guzelsu, N; Kotha, S P
2010-07-01
Previous studies indicate that changes in the longitudinal elastic properties of bone due to changes in mineral content are related to the longitudinal strength of bone tissue. Changes in mineral content are expected to affect bone tissue mechanical properties along all directions, albeit to different extents. However, changes in tissue mechanical properties along the different directions are expected to be correlated to one another. In this study, we investigate if radial, circumferential, and longitudinal moduli are related in bone tissue with varying mineral content. Plexiform bovine femoral bone samples were treated in fluoride ion solutions for a period of 3 and 12 days to obtain bones with 20% and 32% lower effective mineral contents. Transmission ultrasound velocities were obtained in the radial, circumferential, and longitudinal axes of bone and combined with measured densities to obtain corresponding tensorial moduli. Results indicate that moduli decreased with fluoride ion treatments and were significantly correlated to one another (r(2) radial vs. longitudinal = 0.80, r(2) circumferential vs. longitudinal = 0.90, r(2) radial vs. circumferential = 0.85). Densities calculated from using ultrasound parameters, acoustic impedance and transmission velocities, were moderately correlated to those measured by the Archimedes principle (r(2)=0.54, p<0.01). These results suggest that radial and circumferential ultrasound measurements could be used to determine the longitudinal properties of bone and that ultrasound may not be able to predict in vitro densities of bones containing unbonded mineral. Published by Elsevier Ltd.
An analytical model to design circumferential clasps for laser-sintered removable partial dentures.
Alsheghri, Ammar A; Alageel, Omar; Caron, Eric; Ciobanu, Ovidiu; Tamimi, Faleh; Song, Jun
2018-06-21
Clasps of removable partial dentures (RPDs) often suffer from plastic deformation and failure by fatigue; a common complication of RPDs. A new technology for processing metal frameworks for dental prostheses based on laser-sintering, which allows for precise fabrication of clasp geometry, has been recently developed. This study sought to propose a novel method for designing circumferential clasps for laser-sintered RPDs to avoid plastic deformation or fatigue failure. An analytical model for designing clasps with semicircular cross-sections was derived based on mechanics. The Euler-Bernoulli elastic curved beam theory and Castigliano's energy method were used to relate the stress and undercut with the clasp length, cross-sectional radius, alloy properties, tooth type, and retention force. Finite element analysis (FEA) was conducted on a case study and the resultant tensile stress and undercut were compared with the analytical model predictions. Pull-out experiments were conducted on laser-sintered cobalt-chromium (Co-Cr) dental prostheses to validate the analytical model results. The proposed circumferential clasp design model yields results in good agreement with FEA and experiments. The results indicate that Co-Cr circumferential clasps in molars that are 13mm long engaging undercuts of 0.25mm should have a cross-section radius of 1.2mm to provide a retention of 10N and to avoid plastic deformation or fatigue failure. However, shorter circumferential clasps such as those in premolars present high stresses and cannot avoid plastic deformation or fatigue failure. Laser-sintered Co-Cr circumferential clasps in molars are safe, whereas they are susceptible to failure in premolars. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
Direct measurement of hoop strains in the intact and torn human medial meniscus.
Jones, R Spencer; Keene, G C R; Learmonth, D J A; Bickerstaff, D; Nawana, N S; Costi, J J; Pearcy, M J
1996-07-01
OBJECTIVE: To measure the circumferential or hoop strains generated in the medial meniscus during loading of the knee joint and to examine the effect of longitudinal and radial tears in the meniscus on these strain values. DESIGN: An in vitro investigation measuring the circumferential strains in the medial menisci of cadaveric human knees as they were loaded in a materials testing machine. BACKGROUND: The menisci transmit approximately 50% of the load through the knee, the rest being transmitted by direct contact of the articular cartilage. Damage to the menisci will alter the pattern of load transmission as will meniscectomy. This study examined the changes in the mechanics of the meniscus in situ as a result of simulated tears to assess the effect of its load carrying capacity and the implications of surgery to remove part or all of a damaged meniscus. METHODS: Nineteen human cadaveric knees were tested. Windows were made in the joint capsule and strain gauges inserted into the anterior, middle and posterior sections of the medial meniscus. The knees were then loaded to three times body weight at speeds of 50 and 500 mm/min, with the knee joint at 0 degrees and 30 degrees of flexion. The tests were repeated following the creation of a longitudinal or a radial tear in the meniscus. RESULTS: The intact menisci showed significantly less strain in the posterior section compared to the anterior and middle sections (P < 0.003, with strains of 1.54%, 2.86% and 2.65% respectively). With a longitudinal tear this pattern changed with strains decreasing anteriorly and increasing posteriorly. There were also significant differences at different angles of knee joint flexion not seen in the intact meniscus. 50% radial tears reduced the strains anteriorly whilst a complete radial tear completely defunctioned the meniscus. CONCLUSIONS: This study has shown that there are significantly different hoop strains produced in different sections of the medial meniscus under load and
Circumferential distortion modeling of the TF30-P-3 compression system
NASA Technical Reports Server (NTRS)
Mazzawy, R. S.; Banks, G. A.
1977-01-01
Circumferential inlet pressure and temperature distortion testing of the TF30 P-3 turbofan engine was conducted. The compressor system at the test conditions run was modelled according to a multiple segment parallel compressor model. Aspects of engine operation and distortion configuration modelled include the effects of compressor bleeds, relative pressure-temperature distortion alignment and circumferential distortion extent. Model predictions for limiting distortion amplitudes and flow distributions within the compression system were compared with test results in order to evaluate predicted trends. Relatively good agreement was obtained. The model also identified the low pressure compressor as the stall-initiating component, which was in agreement with the data.
Feasibility study of negative lift circumferential type seal for helicopter transmissions
NASA Technical Reports Server (NTRS)
Goldring, E. N.
1977-01-01
A new seal concept, the negative lift circumferential type seal, was evaluated under simulated helicopter transmission conditions. The bore of the circumferential seal contains step type geometry which produces a negative lift that urges the sealing segments towards the shaft surface. The seal size was a 2.5 inch bore and the test speeds were 7000 and 14,250 rpm. During the 300 hour test at typical transmission seal pressure (to 2 psig) the leakage was within acceptable limits and generally less than 0.1 cc/hour during the last 150 hours of testing. The wear to the carbon segments during the 300 hours was negligible.
Miwata, Tomohiro; Oka, Shiro; Tanaka, Shinji; Kagemoto, Kenichi; Sanomura, Yoji; Urabe, Yuji; Hiyama, Toru; Chayama, Kazuaki
2016-09-01
Endoscopic submucosal dissection (ESD) is used to perform en block resection for esophageal squamous cell carcinoma, but it is strongly associated with postoperative stenosis, especially during entire circumferential resection. This study aimed to clarify the risk factors for refractory postoperative stenosis after entire circumferential esophageal ESD. Nineteen patients who underwent entire circumferential esophageal ESD from February 2006 to December 2013 at Hiroshima University Hospital were divided into two groups: refractory postoperative stenosis [≥6 endoscopic balloon dilation (EBD) procedures, 12 lesions in 12 patients] and non-refractory postoperative stenosis (≤5 EBD procedures, 7 lesions in 7 patients). We retrospectively examined the patient factors (age, sex, alcohol consumption, smoking index, and chemoradiation therapy history), tumor factors (location, macroscopic type, fibrosis, and depth), and treatment factors (mean procedure time, entire circumferential resection diameter, muscle layer damage, and steroid administration method) between the two groups. Muscle layer damage (p = 0.019) and ≥5 cm of longitudinal mucosal defect length after entire circumferential esophageal ESD (p = 0.010) were significant factors associated with the refractory group. Regarding the patient and tumor factors, there were no significant differences between the two groups. Our data suggest that refractory post-ESD stenosis occurs after entire circumferential esophageal ESD with muscle layer damage and ≥5 cm of longitudinal mucosal defect length.
Warrier, Satish K; Kong, Joseph Cherng; Guerra, Glen R; Chittleborough, Timothy J; Naik, Arun; Ramsay, Robert G; Lynch, A Craig; Heriot, Alexander G
2018-04-01
Rectal cancer outcomes have improved with the adoption of a multidisciplinary model of care. However, there is a spectrum of quality when viewed from a national perspective, as highlighted by the Consortium for Optimizing the Treatment of Rectal Cancer data on rectal cancer care in the United States. The aim of this study was to assess and identify predictors of circumferential resection margin involvement for rectal cancer across Australasia. A retrospective study from a prospectively maintained binational colorectal cancer database was interrogated. This study is based on a binational colorectal cancer audit database. Clinical information on all consecutive resected rectal cancer cases recorded in the registry from 2007 to 2016 was retrieved, collated, and analyzed. The primary outcome measure was positive circumferential resection margin, measured as a resection margin ≤1 mm. A total of 3367 patients were included, with 261 (7.5%) having a positive circumferential resection margin. After adjusting for hospital and surgeon volume, hierarchical logistic regression analysis identified a 6-variable model encompassing the independent predictors, including urgent operation, abdominoperineal resection, open technique, low rectal cancer, T3 to T4, and N1 to N2. The accuracy of the model was 92.3%, with an receiver operating characteristic of 0.783 (p < 0.0001). The quantitative risk associated with circumferential resection margin positivity ranged from <1% (no risk factors) to 43% (6 risk factors). This study was limited by the lack of recorded long-term outcomes associated with circumferential resection margin positivity. The rate of circumferential resection margin involvement in patients undergoing rectal cancer resection in Australasia is low and is influenced by a number of factors. Risk stratification of outcome is important with the increasing demand for publicly accessible quality data. See Video Abstract at http://links.lww.com/DCR/A512.
Tks5-dependent formation of circumferential podosomes/invadopodia mediates cell-cell fusion.
Oikawa, Tsukasa; Oyama, Masaaki; Kozuka-Hata, Hiroko; Uehara, Shunsuke; Udagawa, Nobuyuki; Saya, Hideyuki; Matsuo, Koichi
2012-05-14
Osteoclasts fuse to form multinucleated cells during osteoclastogenesis. This process is mediated by dynamic rearrangement of the plasma membrane and cytoskeleton, and it requires numerous factors, many of which have been identified. The underlying mechanism remains obscure, however. In this paper, we show that Tks5, a master regulator of invadopodia in cancer cells, is crucial for osteoclast fusion downstream of phosphoinositide 3-kinase and Src. Expression of Tks5 was induced during osteoclastogenesis, and prevention of this induction impaired both the formation of circumferential podosomes and osteoclast fusion without affecting cell differentiation. Tyrosine phosphorylation of Tks5 was attenuated in Src-/- osteoclasts, likely accounting for defects in podosome organization and multinucleation in these cells. Circumferential invadopodia formation in B16F0 melanoma cells was also accompanied by Tks5 phosphorylation. Co-culture of B16F0 cells with osteoclasts in an inflammatory milieu promoted the formation of melanoma-osteoclast hybrid cells. Our results thus reveal an unexpected link between circumferential podosome/invadopodium formation and cell-cell fusion in and beyond osteoclasts.
Tks5-dependent formation of circumferential podosomes/invadopodia mediates cell–cell fusion
Oyama, Masaaki; Kozuka-Hata, Hiroko; Uehara, Shunsuke; Udagawa, Nobuyuki; Saya, Hideyuki; Matsuo, Koichi
2012-01-01
Osteoclasts fuse to form multinucleated cells during osteoclastogenesis. This process is mediated by dynamic rearrangement of the plasma membrane and cytoskeleton, and it requires numerous factors, many of which have been identified. The underlying mechanism remains obscure, however. In this paper, we show that Tks5, a master regulator of invadopodia in cancer cells, is crucial for osteoclast fusion downstream of phosphoinositide 3-kinase and Src. Expression of Tks5 was induced during osteoclastogenesis, and prevention of this induction impaired both the formation of circumferential podosomes and osteoclast fusion without affecting cell differentiation. Tyrosine phosphorylation of Tks5 was attenuated in Src−/− osteoclasts, likely accounting for defects in podosome organization and multinucleation in these cells. Circumferential invadopodia formation in B16F0 melanoma cells was also accompanied by Tks5 phosphorylation. Co-culture of B16F0 cells with osteoclasts in an inflammatory milieu promoted the formation of melanoma–osteoclast hybrid cells. Our results thus reveal an unexpected link between circumferential podosome/invadopodium formation and cell–cell fusion in and beyond osteoclasts. PMID:22584907
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lo, Queenie; Liverpool Hospital, Sydney, NSW; Hee, Leia
Purpose: To evaluate 2-dimensional strain imaging (SI) for the detection of subclinical myocardial dysfunction during and after radiation therapy (RT). Methods and Materials: Forty women with left-sided breast cancer, undergoing only adjuvant RT to the left chest, were prospectively recruited. Standard echocardiography and SI were performed at baseline, during RT, and 6 weeks after RT. Strain (S) and strain rate (Sr) parameters were measured in the longitudinal, circumferential, and radial planes. Correlation of change in global longitudinal strain (GLS % and Δ change) and the volume of heart receiving 30 Gy (V30) and mean heart dose (MHD) were examined. Results: Leftmore » ventricular ejection fraction was unchanged; however, longitudinal systolic S and Sr and radial S were significantly reduced during RT and remained reduced at 6 weeks after treatment [longitudinal S (%) −20.44 ± 2.66 baseline vs −18.60 ± 2.70* during RT vs −18.34 ± 2.86* at 6 weeks after RT; longitudinal Sr (s{sup −1}) −1.19 ± 0.21 vs −1.06 ± 0.18* vs −1.06 ± 0.16*; radial S (%) 56.66 ± 18.57 vs 46.93 ± 14.56* vs 49.22 ± 15.81*; *P<.05 vs baseline]. Diastolic Sr were only reduced 6 weeks after RT [longitudinal E Sr (s{sup −1}) 1.47 ± 0.32 vs 1.29 ± 0.27*; longitudinal A Sr (s{sup −1}) 1.19 ± 0.31 vs 1.03 ± 0.24*; *P<.05 vs baseline], whereas circumferential strain was preserved throughout. A modest correlation between S and Sr and V30 and MHD was observed (GLS Δ change and V30 ρ = 0.314, P=.05; GLS % change and V30 ρ = 0.288, P=.076; GLS Δ change and MHD ρ = 0.348, P=.03; GLS % change and MHD ρ = 0.346, P=.031). Conclusions: Subclinical myocardial dysfunction was detected by 2-dimensional SI during RT, with changes persisting 6 weeks after treatment, though long-term effects remain unknown. Additionally, a modest correlation between strain reduction and radiation dose was observed.« less
Nonlinear Analysis of Two-phase Circumferential Motion in the Ablation Circumstance
NASA Astrophysics Data System (ADS)
Xiao-liang, Xu; Hai-ming, Huang; Zi-mao, Zhang
2010-05-01
In aerospace craft reentry and solid rocket propellant nozzle, thermal chemistry ablation is a complex process coupling with convection, heat transfer, mass transfer and chemical reaction. Based on discrete vortex method (DVM), thermal chemical ablation model and particle kinetic model, a computational module dealing with the two-phase circumferential motion in ablation circumstance is designed, the ablation velocity and circumferential field can be thus calculated. The calculated nonlinear time series are analyzed in chaotic identification method: relative chaotic characters such as correlation dimension and the maximum Lyapunov exponent are calculated, fractal dimension of vortex bulbs and particles distributions are also obtained, thus the nonlinear ablation process can be judged as a spatiotemporal chaotic process.
Biomechanical testing of circumferential instrumentation after cervical multilevel corpectomy.
Hartmann, Sebastian; Thomé, Claudius; Keiler, Alexander; Fritsch, Helga; Hegewald, Aldemar Andres; Schmölz, Werner
2015-12-01
Biomechanical investigation. This study describes ex vivo evaluation of the range of motion (ROM) to characterize the stability and need for additional dorsal fixation after cervical single-level, two-level or multilevel corpectomy (CE) to elucidate biomechanical differences between anterior-only and supplemental dorsal instrumentation. Twelve human cervical cadaveric spines were loaded in a spine tester with pure moments of 1.5 Nm in lateral bending (LB), flexion/extension (FE), and axial rotation (AR), followed by two cyclic loading periods for three-level corpectomies. After each cyclic loading session, flexibility tests were performed for anterior-only instrumentation (group_1, six specimens) and circumferential instrumentation (group_2, six specimens). The flexibility tests for all circumferential instrumentations showed a significant decrease in ROM in comparison with the intact state and anterior-only instrumentations. In comparison with the intact state, supplemental dorsal instrumentation after three-level CE reduced the ROM to 12% (±10%), 9% (±12%), and 22% (±18%) in LB, FE, and AR, respectively. The anterior-only construct outperformed the intact state only in FE, with a significant ROM reduction to 57% (±35 %), 60% (±27%), and 62% (±35%) for one-, two- and three-level CE, respectively. The supplemental dorsal instrumentation provided significantly more stability than the anterior-only instrumentation regardless of the number of levels resected and the direction of motion. After cyclic loading, the absolute differences in stability between the two instrumentations remained significant while both instrumentations showed a comparable increase of ROM after cyclic loading. The large difference in the absolute ROM of anterior-only compared to circumferential instrumentations supports a dorsal support in case of three-level approaches.
NASA Astrophysics Data System (ADS)
Xu, Yingshun; Singh, Janak; Siang, Teo Hui; Ramakrishna, Kotlanka; Premchandran, C. S.; Sheng, Chen Wei; Kuan, Chuah Tong; Chen, Nanguang; Olivo, Malini C.; Sheppard, Colin J. R.
2007-07-01
In this paper, we present a non-rotatory circumferential scanning optical probe integrated with a MEMS scanner for in vivo endoscopic optical coherence tomography (OCT). OCT is an emerging optical imaging technique that allows high resolution cross-sectional imaging of tissue microstructure. To extend its usage to endoscopic applications, a miniaturized optical probe based on Microelectromechanical Systems (MEMS) fabrication techniques is currently desired. A 3D electrothermally actuated micromirror realized using micromachining single crystal silicon (SCS) process highlights its very large angular deflection, about 45 degree, with low driving voltage for safety consideration. The micromirror is integrated with a GRIN lens into a waterproof package which is compatible with requirements for minimally invasive endoscopic procedures. To implement circumferential scanning substantially for diagnosis on certain pathological conditions, such as Barret's esophagus, the micromirror is mounted on 90 degree to optical axis of GRIN lens. 4 Bimorph actuators that are connected to the mirror on one end via supporting beams and springs are selected in this micromirror design. When actuators of the micromirror are driven by 4 channels of sinusoidal waveforms with 90 degree phase differences, beam focused by a GRIN is redirected out of the endoscope by 45 degree tilting mirror plate and achieve circumferential scanning pattern. This novel driving method making full use of very large angular deflection capability of our micromirror is totally different from previously developed or developing micromotor-like rotatory MEMS device for circumferential scanning.
Levy, Philip T; Machefsky, Aliza; Sanchez, Aura A; Patel, Meghna D; Rogal, Sarah; Fowler, Susan; Yaeger, Lauren; Hardi, Angela; Holland, Mark R; Hamvas, Aaron; Singh, Gautam K
2016-03-01
Establishment of the range of reference values and associated variations of two-dimensional speckle-tracking echocardiography (2DSTE)-derived left ventricular (LV) strain is a prerequisite for its routine clinical adoption in pediatrics. The aims of this study were to perform a meta-analysis of normal ranges of LV global longitudinal strain (GLS), global circumferential strain (GCS), and global radial strain (GRS) measurements derived by 2DSTE in children and to identify confounding factors that may contribute to variance in reported measures. A systematic review was launched in MEDLINE, Embase, Scopus, the Cumulative Index to Nursing and Allied Health Literature, and the Cochrane Library. Search hedges were created to cover the concepts of pediatrics, STE, and left-heart ventricle. Two investigators independently identified and included studies if they reported 2DSTE-derived LV GLS, GCS, or GRS. The weighted mean was estimated by using random effects models with 95% CIs, heterogeneity was assessed using the Cochran Q statistic and the inconsistency index (I(2)), and publication bias was evaluated using the Egger test. Effects of demographic (age), clinical, and vendor variables were assessed in a metaregression. The search identified 2,325 children from 43 data sets. The reported normal mean values of GLS among the studies varied from -16.7% to -23.6% (mean, -20.2%; 95% CI, -19.5% to -20.8%), GCS varied from -12.9% to -31.4% (mean, -22.3%; 95% CI, -19.9% to -24.6%), and GRS varied from 33.9% to 54.5% (mean, 45.2%; 95% CI, 38.3% to 51.7%). Twenty-six studies reported longitudinal strain only from the apical four-chamber view, with a mean of -20.4% (95% CI, -19.8% to -21.7%). Twenty-three studies reported circumferential strain (mean, -20.3%; 95% CI, -19.4% to -21.2%) and radial strain (mean, 46.7%; 95% CI, 42.3% to 51.1%) from the short-axis view at the midventricular level. A significant apex-to-base segmental longitudinal strain gradient (P < .01) was observed
Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Liang, Kaicheng; Wang, Zhao; Cleveland, Cody; Booth, Lucas; Potsaid, Benjamin; Jayaraman, Vijaysekhar; Cable, Alex E; Mashimo, Hiroshi; Langer, Robert; Traverso, Giovanni; Fujimoto, James G
2016-08-01
We demonstrate a micromotor balloon imaging catheter for ultrahigh speed endoscopic optical coherence tomography (OCT) which provides wide area, circumferential structural and angiographic imaging of the esophagus without contrast agents. Using a 1310 nm MEMS tunable wavelength swept VCSEL light source, the system has a 1.2 MHz A-scan rate and ~8.5 µm axial resolution in tissue. The micromotor balloon catheter enables circumferential imaging of the esophagus at 240 frames per second (fps) with a ~30 µm (FWHM) spot size. Volumetric imaging is achieved by proximal pullback of the micromotor assembly within the balloon at 1.5 mm/sec. Volumetric data consisting of 4200 circumferential images of 5,000 A-scans each over a 2.6 cm length, covering a ~13 cm(2) area is acquired in <18 seconds. A non-rigid image registration algorithm is used to suppress motion artifacts from non-uniform rotational distortion (NURD), cardiac motion or respiration. En face OCT images at various depths can be generated. OCT angiography (OCTA) is computed using intensity decorrelation between sequential pairs of circumferential scans and enables three-dimensional visualization of vasculature. Wide area volumetric OCT and OCTA imaging of the swine esophagus in vivo is demonstrated.
Yoshihara, Hiroyuki; Abumi, Kuniyoshi; Ito, Manabu; Kotani, Yoshihisa; Sudo, Hideki; Takahata, Masahiko
2013-11-01
Surgical treatment for severe circumferentially fixed cervical kyphosis has been challenging. Both anterior and posterior releases are necessary to provide the cervical mobility necessary for fusion in a corrected position. In two case reports, we describe the circumferential osteotomy of anterior-posterior-anterior surgical sequence, and the efficacy of this technique when cervical pedicle screw fixation for severe fixed cervical kyphosis is used. Etiology of fixed cervical kyphosis was unknown in one patient and neurofibromatosis in one patient. Both patients had severe fixed cervical kyphosis as determined by cervical radiographs and underwent circumferential osteotomy and fixation via an anterior-posterior-anterior surgical sequence and correction of kyphosis by pedicle screw fixation. Severe fixed cervical kyphosis was treated successfully by the use of circumferential osteotomy and pedicle screw fixation. The surgical sequence described in this report is a reasonable approach for severe circumferentially fixed cervical kyphosis and short segment fixation can be achieved using pedicle screws. Copyright © 2013 Elsevier Inc. All rights reserved.
Kılıcgedik, Alev; Kahveci, Gokhan; Gurbuz, Ahmet Seyfeddin; Karabay, Can Yucel; Guler, Ahmet; Efe, Suleyman Cagan; Aung, Soe Moe; Arslantas, Ugur; Demir, Serdar; Izgi, Ibrahim Akin; Kirma, Cevat
2017-04-01
The role of papillary muscle function in severe mitral regurgitation with preserved and reduced left ventricular ejection fraction and the method of choice to evaluate PM have still been the subjects of controversy. To evaluate and compare papillary muscle function in and between patients with severe degenerative and functional mitral regurgitation by using the free strain method. 64 patients with severe mitral regurgitation - 39 patients with degenerative mitral regurgitation (DMR group) and 25 patients with severe functional mitral regurgitation (FMR group) - and 30 control subjects (control group) were included in the study. Papillary muscle function was evaluated through the free strain method from apical four chamber images of the anterolateral papillary muscle (APM) and from apical three chamber images of the posteromedial papillary muscle (PPM). Global left ventricular longitudinal and circumferential strains were evaluated by applying 2D speckle tracking imaging. Global left ventricular longitudinal strain (DMR group, -17 [-14.2/-20]; FMR group, -9 [-7/-10.7]; control group, -20 [-18/-21] p < 0.001), global left ventricular circumferential strain (DMR group, -20 [-14.5/-22.7]; FMR group, -10 [-7/-12]; control group, -23 [-21/-27.5] p < 0.001) and papillary musle strains (PPMS; DMR group, -30.5 [-24/-46.7]; FMR group, -18 [-12/-30]; control group; -43 [-34.5/-39.5] p < 0.001; APMS; DMR group, (-35 [-23.5/-43]; FMR group, -20 [-13.5/-26]; control group, -40 [-32.5/-48] p < 0.001) were significantly different among all groups. APMS and PPMS were highly correlated with LVEF (p < 0.001, p < 0.001; respectively), GLS (p < 0.001, p < 0.001; respectively) and GCS (p < 0.001, p < 0.00; respectively) of LV among all groups. No correlation was found between papillary muscle strains and effective orifice area (EOA) in both groups of severe mitral regurgitation. Measuring papillary muscle longitudinal strain by the free strain method is practical and applicable
NASA Astrophysics Data System (ADS)
Wu, Bin; Su, Yipin; Chen, Weiqiu; Zhang, Chuanzeng
2017-02-01
Soft electroactive (EA) tube actuators and many other cylindrical devices have been proposed recently in literature, which show great advantages over those made from conventional hard solid materials. However, their practical applications may be limited because these soft EA devices are prone to various failure modes. In this paper, we present an analysis of the guided circumferential elastic waves in soft EA tube actuators, which has potential applications in the in-situ nondestructive evaluation (NDE) or online structural health monitoring (SHM) to detect structural defects or fatigue cracks in soft EA tube actuators and in the self-sensing of soft EA tube actuators based on the concept of guided circumferential elastic waves. Both circumferential SH and Lamb-type waves in an incompressible soft EA cylindrical tube under inhomogeneous biasing fields are considered. The biasing fields, induced by the application of an electric voltage difference to the electrodes on the inner and outer cylindrical surfaces of the EA tube in addition to an axial pre-stretch, are inhomogeneous in the radial direction. Dorfmann and Ogden's theory of nonlinear electroelasticity and the associated linear theory for small incremental motion constitute the basis of our analysis. By means of the state-space formalism for the incremental wave motion along with the approximate laminate technique, dispersion relations are derived in a particularly efficient way. For a neo-Hookean ideal dielectric model, the proposed approach is first validated numerically. Numerical examples are then given to show that the guided circumferential wave propagation characteristics are significantly affected by the inhomogeneous biasing fields and the geometrical parameters. Some particular phenomena such as the frequency veering and the nonlinear dependence of the phase velocity on the radial electric voltage are discussed. Our numerical findings demonstrate that it is feasible to use guided circumferential
Wu, Jie; Chen, Qi-Xun; Teng, Li-song; Krasna, Mark J
2014-02-01
To assess the prognostic significance of positive circumferential resection margin on overall survival in patients with esophageal cancer, a systematic review and meta-analysis was performed. Studies were identified from PubMed, EMBASE, and Web of Science. Survival data were extracted from eligible studies to compare overall survival in patients with a positive circumferential resection margin with patients having a negative circumferential resection margin according to the Royal College of Pathologists (RCP) criteria and the College of American Pathologists (CAP) criteria. Survival data were pooled with hazard ratios (HRs) and their corresponding 95% confidence intervals (CIs). A random-effects model meta-analysis on overall survival was performed. The pooled HRs for survival were 1.510 (95% CI, 1.329-1.717; p<0.001) and 2.053 (95% CI, 1.597-2.638; p<0.001) according to the RCP and CAP criteria, respectively. Positive circumferential resection margin was associated with worse survival in patients with T3 stage disease according to the RCP (HR, 1.381; 95% CI, 1.028-1.584; p=0.001) and CAP (HR, 2.457; 95% CI, 1.902-3.175; p<0.001) criteria, respectively. Positive circumferential resection margin was associated with worse survival in patients receiving neoadjuvant therapy according to the RCP (HR, 1.676; 95% CI, 1.023-2.744; p=0.040) and CAP (HR, 1.847; 95% CI, 1.226-2.78; p=0.003) criteria, respectively. Positive circumferential resection margin is associated with poor prognosis in patients with esophageal cancer, particularly in patients with T3 stage disease and patients receiving neoadjuvant therapy. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Circumferential truncal contouring: the belt lipectomy.
Aly, Al; Mueller, Melissa
2014-10-01
The primary goal of belt lipectomy surgery is to improve the contour of the inferior truncal circumferential unit and to place the resultant scar in natural junctions. Excessive intra-abdominal content is a contraindication for belt lipectomy. The higher the presenting patient's body mass index (BMI), the higher the risk of postoperative complications and the less impressive the results. The converse is also true: the lower the BMI, the lower the risk of complications and the better the results. The most common complications are small wound separations and seromas. Copyright © 2014 Elsevier Inc. All rights reserved.
Yang, Chia-Hung; Chou, Chung-Chuan; Hung, Kuo-Chun; Wen, Ming-Shien; Chang, Po-Cheng; Wo, Hung-Ta; Lee, Cheng-Hung; Lin, Fen-Chiung
2017-02-01
Radiofrequency catheter ablation (RFCA) is a potentially curative treatment for atrial fibrillation (AF), however, whether or not additional left atrial (LA) linear ablation for recurrent AF adversely affects LA remodeling is unknown. Thirty-eight patients experiencing AF recurrence after the 1st circumferential pulmonary vein isolation (CPVI) underwent a repeat RFCA, including 20 and 18 patients receiving a repeat CPVI (group I) or CPVI plus LA linear ablation (group II), respectively. 2-D echocardiography was performed during sinus rhythm within 24h, at 1-m and 6-m after RFCA. Longitudinal strains and strain rate were measured with speckle-tracking echocardiography. The standard deviation of contraction duration was defined as LA mechanical dispersion. One and two patients experienced AF recurrence after the 2nd RFCA in group I and II, respectively (P=NS). The 1st CPVI with AF recurrence did not reduce LA size significantly in two groups. After a repeat CPVI, LA diameter but not LA maximal and minimal volume was significantly reduced in group I; additional LA linear ablation significantly decreased LA diameter, maximal and minimal volume in group II. However, there was no significant difference in LA emptying function, global and segmental LA strain and strain rate among the baseline, 1-m and 6-m follow-up in two groups. RFCA did not significantly increase LA mechanical dispersion regardless of the AF ablation strategies. In patients with recurrent AF, a successful repeat CPVI with or without additional LA linear ablation reduced LA size without significant deleterious effects on LA function and mechanical dispersion. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Releasing the circumferential fixation of the medial meniscus does not affect its kinematics.
Vrancken, A C T; van Tienen, T G; Hannink, G; Janssen, D; Verdonschot, N; Buma, P
2014-12-01
Meniscal functioning depends on the fixation between the meniscal horns and the surrounding tissues. It is unknown, however, whether the integration between the outer circumference of the medial meniscus and the knee capsule/medial collateral ligament also influences the biomechanical behavior of the meniscus. Therefore, we aimed to determine whether detaching and resuturing the circumferential fixation of the medial meniscus influence its kinematic pattern. Human cadaveric knee joints were flexed (0°-30°-60°-90°) in a knee loading rig, in neutral orientation and under internal and external tibial torques. Roentgen stereophotogrammetric analysis was used to determine the motion of the meniscus in anteroposterior (AP) and mediolateral (ML) directions. Three fixation conditions were evaluated: (I) intact, (II) detached and (III) resutured. Detaching and resuturing the circumferential fixation did not alter the meniscal motion pattern in either the AP or ML direction. Applying an additional internal tibial torque caused the medial meniscus to move slightly anteriorly, and an external torque caused a little posterior translation with respect to the neutral situation. These patterns did not change when the circumferential fixation condition was altered. This study demonstrated that the motion pattern of the medial meniscus is independent of its fixation to the knee capsule and medial collateral ligament. The outcomes of this study can be deployed to design the fixation strategy of a permanent meniscus prosthesis. As peripheral fixation is a complicated step during meniscal replacement, the surgical procedure is considerably simplified when non-resorbable implants do not require circumferential fixation. Copyright © 2014 Elsevier B.V. All rights reserved.
Showalter, Brent L.; DeLucca, John F.; Peloquin, John M.; Cortes, Daniel H.; Yoder, Jonathon H.; Jacobs, Nathan T.; Wright, Alexander C.; Gee, James C.; Vresilovic, Edward J.; Elliott, Dawn M.
2017-01-01
Tissue strain is an important indicator of mechanical function, but is difficult to noninvasively measure in the intervertebral disc. The objective of this study was to generate a disc strain template, a 3D average of disc strain, of a group of human L4–L5 discs loaded in axial compression. To do so, magnetic resonance images of uncompressed discs were used to create an average disc shape. Next, the strain tensors were calculated pixel-wise by using a previously developed registration algorithm. Individual disc strain tensor components were then transformed to the template space and averaged to create the disc strain template. The strain template reduced individual variability while highlighting group trends. For example, higher axial and circumferential strains were present in the lateral and posterolateral regions of the disc, which may lead to annular tears. This quantification of group-level trends in local 3D strain is a significant step forward in the study of disc biomechanics. These trends were compared to a finite element model that had been previously validated against the disc-level mechanical response. Depending on the strain component, 81–99% of the regions within the finite element model had calculated strains within one standard deviation of the template strain results. The template creation technique provides a new measurement technique useful for a wide range of studies, including more complex loading conditions, the effect of disc pathologies and degeneration, damage mechanisms, and design and evaluation of treatments. PMID:26694516
McNabb, Ryan P.; Challa, Pratap; Kuo, Anthony N.; Izatt, Joseph A.
2015-01-01
Clinically, gonioscopy is used to provide en face views of the ocular angle. The angle has been imaged with optical coherence tomography (OCT) through the corneoscleral limbus but is currently unable to image the angle from within the ocular anterior chamber. We developed a novel gonioscopic OCT system that images the angle circumferentially from inside the eye through a custom, radially symmetric, gonioscopic contact lens. We present, to our knowledge, the first 360° circumferential volumes (two normal subjects, two subjects with pathology) of peripheral iris and iridocorneal angle structures obtained via an internal approach not typically available in the clinic. PMID:25909021
Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Liang, Kaicheng; Wang, Zhao; Cleveland, Cody; Booth, Lucas; Potsaid, Benjamin; Jayaraman, Vijaysekhar; Cable, Alex E.; Mashimo, Hiroshi; Langer, Robert; Traverso, Giovanni; Fujimoto, James G.
2016-01-01
We demonstrate a micromotor balloon imaging catheter for ultrahigh speed endoscopic optical coherence tomography (OCT) which provides wide area, circumferential structural and angiographic imaging of the esophagus without contrast agents. Using a 1310 nm MEMS tunable wavelength swept VCSEL light source, the system has a 1.2 MHz A-scan rate and ~8.5 µm axial resolution in tissue. The micromotor balloon catheter enables circumferential imaging of the esophagus at 240 frames per second (fps) with a ~30 µm (FWHM) spot size. Volumetric imaging is achieved by proximal pullback of the micromotor assembly within the balloon at 1.5 mm/sec. Volumetric data consisting of 4200 circumferential images of 5,000 A-scans each over a 2.6 cm length, covering a ~13 cm2 area is acquired in <18 seconds. A non-rigid image registration algorithm is used to suppress motion artifacts from non-uniform rotational distortion (NURD), cardiac motion or respiration. En face OCT images at various depths can be generated. OCT angiography (OCTA) is computed using intensity decorrelation between sequential pairs of circumferential scans and enables three-dimensional visualization of vasculature. Wide area volumetric OCT and OCTA imaging of the swine esophagus in vivo is demonstrated. PMID:27570688
Kanai, Nobuo; Yamato, Masayuki; Ohki, Takeshi; Yamamoto, Masakazu; Okano, Teruo
2012-10-01
Endoscopic submucosal dissection (ESD) is an accepted treatment for early esophageal carcinoma. However, resection of a large mucosal area, as with circumferential ESD, induces severe stricture formation. To evaluate the efficacy of cultured autologous epidermal cell sheets to prevent severe esophageal constriction after circumferential ESD. Animal study. University institute. Eight pigs underwent circumferential esophageal ESD while under general anesthesia. In 4 pigs, fabricated autologous epidermal cell sheets were endoscopically transplanted to the central ESD sites immediately after the ESD. The other 4 pigs underwent circumferential ESD only. Necropsy and histological assessment were performed at 1 and 2 weeks post-ESD. Weight gain, degree of mucosal constriction, and histological assessments. All pigs in the control group showed severe esophageal constriction after 2 weeks. The control and transplanted groups had weight gains of -10.3% and 0.3% (P = .03), respectively, and the mean degrees of constriction were 88% and 56% (P < .01), respectively. Early re-epithelialization and mild fibrosis in the muscularis were observed in the transplanted group. Animal study, small sample size. Fabricated autologous skin epidermal cell sheets would be useful in preventing severe esophageal constriction after circumferential ESD. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Latif, R.; Aassif, E.; Maze, G.; Decultot, D.; Moudden, A.; Faiz, B.
2000-01-01
This paper presents a study of the group velocity dispersion of some circumferential waves propagating around an elastic tube. The dispersive character of the circumferential waves is theoretically known, but the experimental measurement of the group velocity in a dispersive medium is still a complex operation. We have determined the characteristics of the circumferential wave dispersion for aluminium and steel tubes using a time-frequency representation. Among these time-frequency techniques, the Wigner-Ville distribution (WVD) is used here for its interesting properties in terms of acoustic applications. The WVD is applied to the analysis of the dispersion of S0 symmetric and A1 antisymmetric circumferential waves propagating around a tube with a radii ratio equal to 0.95 (internal radius:external radius). This allowed us to determine their group velocities and reduced cutoff frequencies. The results obtained are in good agreement with the calculated values using the proper modes theory.
Gemignani, Tiago; Matos-Souza, José R; Coelho, Otávio R; Franchini, Kleber G; Nadruz, Wilson
2008-11-01
Atherosclerosis of peripheral arteries typically affects vessels of the lower limbs, suggesting that local hemodynamic stimuli play a role in this process. Our study evaluated the effects of body postural changes on carotid and popliteal blood pressure, circumferential wall tension (CWT) and arterial strain, and investigated the relationship between such hemodynamic parameters and intima-media thickness (IMT) of these arteries. One hundred seventeen nondiabetic, nonhypertensive, nonsmoker subjects (48 men and 69 women) were enrolled and had their blood pressure measured in the arm and calf in supine and orthostatic positions. Echo-doppler analysis evaluated the common carotid and popliteal arteries after blood pressure measurements, while CWT was calculated according to Laplace's law. The results showed that changing from supine to orthostatic posture increased blood pressure and CWT in popliteal but not in carotid arteries. Partial correlation analysis adjusted for age and body mass index revealed no major relationship between IMT of the studied vessels and local blood pressure or arterial strain. Conversely, supine and orthostatic CWT exhibited comparable correlation coefficients with carotid IMT, while orthostatic CWT displayed a stronger relationship with popliteal IMT than with supine CWT. These results were confirmed by multiple linear regression analysis that included age, sex, body mass index, lipid fractions and glucose as independent variables. Overall, our results indicate that orthostatic CWT is a stronger hemodynamic predictor of popliteal IMT than supine CWT, suggesting that erectile posture may be a potential risk factor for popliteal atherosclerosis because it increases the local hemodynamic burden. (Hypertens Res 2008; 31: 2059-2064).
Madan, S S; Boeree, N R
2003-12-01
Posterior lumbar interbody fusion (PLIF) restores disc height, the load bearing ability of anterior ligaments and muscles, root canal dimensions, and spinal balance. It immobilizes the painful degenerate spinal segment and decompresses the nerve roots. Anterior lumbar interbody fusion (ALIF) does the same, but could have complications of graft extrusion, compression and instability contributing to pseudarthrosis in the absence of instrumentation. The purpose of this study was to assess and compare the outcome of instrumented circumferential fusion through a posterior approach [PLIF and posterolateral fusion (PLF)] with instrumented ALIF using the Hartshill horseshoe cage, for comparable degrees of internal disc disruption and clinical disability. It was designed as a prospective study, comparing the outcome of two methods of instrumented interbody fusion for internal disc disruption. Between April 1994 and June 1998, the senior author (N.R.B.) performed 39 instrumented ALIF procedures and 35 instrumented circumferential fusion with PLIF procedures. The second author, an independent assessor (S.M.), performed the entire review. Preoperative radiographic assessment included plain radiographs, magnetic resonance imaging (MRI) and provocative discography in all the patients. The outcome in the two groups was compared in terms of radiological improvement and clinical improvement, measured on the basis of improvement of back pain and work capacity. Preoperatively, patients were asked to fill out a questionnaire giving their demographic details, maximum walking distance and current employment status in order to establish the comparability of the two groups. Patient assessment was with the Oswestry Disability Index, quality of life questionnaire (subjective), pain drawing, visual analogue scale, disability benefit, compensation status, and psychological profile. The results of the study showed a satisfactory outcome (score< or =30) on the subjective (quality of life
Circumferential pressure distributions in a model labyrinth seal
NASA Technical Reports Server (NTRS)
Leong, Y. M. M. S.; Brown, R. D.
1982-01-01
A research program to isolate and study leakage flow through labyrinth glands was initiated. Circumferential pressure distributions were measured in the labyrinth glands with geometry appropriate to the high pressure labyrinths in large steam turbines. Knowledge of this pressure distribution is essential as it is this unequal pressure field that results in the destabilizing force. Parameters that are likely to affect the pressure distributions are incorporated into the test rig. Some preliminary pressure profiles are presented.
Circumferential finger measurements utilizing a torque meter to increase reliability.
King, T I
1993-01-01
The purpose of this study was to compare the reliabilities of two methods of measuring finger circumference. Traditionally, finger circumference is determined clinically by the use of a tape measure. In this study, a tape-measure device for recording finger circumference utilizing a torque meter was compared with the traditional method to determine reliability differences. Ninety-two occupational therapists and occupational therapy students obtained circumferential measurements of the author's left index finger at the middle of the proximal phalanx utilizing the two methods. The readings obtained for each method were analyzed to determine the coefficient of variation and to compare their variances. The coefficient of variation for the traditional method was 2.92 and for the device utilizing the torque meter was 0.75. The F ratio was 15.63, which is significant at the 0.01 level. The results of this study indicate greater interrater reliability using a device that can accurately measure torque and allow the therapist to control the amount of tension applied when obtaining circumferential measurements using a tape measure.
NASA Technical Reports Server (NTRS)
Koch, L. Danielle
2012-01-01
Fan inflow distortion tone noise has been studied computationally and experimentally. Data from two experiments in the NASA Glenn Advanced Noise Control Fan rig have been used to validate acoustic predictions. The inflow to the fan was distorted by cylindrical rods inserted radially into the inlet duct one rotor chord length upstream of the fan. The rods were arranged in both symmetric and asymmetric circumferential patterns. In-duct and farfield sound pressure level measurements were recorded. It was discovered that for positive circumferential modes, measured circumferential mode sound power levels in the exhaust duct were greater than those in the inlet duct and for negative circumferential modes, measured total circumferential mode sound power levels in the exhaust were less than those in the inlet. Predicted trends in overall sound power level were proven to be useful in identifying circumferentially asymmetric distortion patterns that reduce overall inlet distortion tone noise, as compared to symmetric arrangements of rods. Detailed comparisons between the measured and predicted radial mode sound power in the inlet and exhaust duct indicate limitations of the theory.
Davidson, Rebecca M.; Hasan, Nabeeh A.; de Moura, Vinicius Calado Nogueira; Duarte, Rafael Silva; Jackson, Mary; Strong, Michael
2013-01-01
Rapidly growing, non-tuberculous mycobacteria (NTM) in the Mycobacterium abscessus (MAB) species are emerging pathogens that cause various diseases including skin and respiratory infections. The species has undergone recent taxonomic nomenclature refinement, and is currently recognized as two subspecies, M. abscessus subsp. abscessus (MAB-A) and M. abscessus subsp. bolletii (MAB-B). The recently reported outbreaks of MAB-B in surgical patients in Brazil from 2004 to 2009 and in cystic fibrosis patients in the United Kingdom (UK) in 2006 to 2012 underscore the need to investigate the genetic diversity of clinical MAB strains. To this end, we sequenced the genomes of two Brazilian MAB-B epidemic isolates (CRM-0019 and CRM-0020) derived from an outbreak of skin infections in Rio de Janeiro, two unrelated MAB strains from patients with pulmonary infections in the United States (US) (NJH8 and NJH11) and one type MAB-B strain (CCUG 48898) and compared them to 25 publically available genomes of globally diverse MAB strains. Genome-wide analyses of 27,598 core genome single nucleotide polymorphisms (SNPs) revealed that the two Brazilian derived CRM strains are nearly indistinguishable from one another and are more closely related to UK outbreak isolates infecting CF patients than to strains from the US, Malaysia or France. Comparative genomic analyses of six closely related outbreak strains revealed geographic-specific large-scale insertion/deletion variation that corresponds to bacteriophage insertions and recombination hotspots. Our study integrates new genome sequence data with existing genomic information to explore the global diversity of infectious M. abscessus isolates and to compare clinically relevant outbreak strains from different continents. PMID:24055961
Validating a new methodology for strain estimation from cardiac cine MRI
NASA Astrophysics Data System (ADS)
Elnakib, Ahmed; Beache, Garth M.; Gimel'farb, Georgy; Inanc, Tamer; El-Baz, Ayman
2013-10-01
This paper focuses on validating a novel framework for estimating the functional strain from cine cardiac magnetic resonance imaging (CMRI). The framework consists of three processing steps. First, the left ventricle (LV) wall borders are segmented using a level-set based deformable model. Second, the points on the wall borders are tracked during the cardiac cycle based on solving the Laplace equation between the LV edges. Finally, the circumferential and radial strains are estimated at the inner, mid-wall, and outer borders of the LV wall. The proposed framework is validated using synthetic phantoms of the material strains that account for the physiological features and the LV response during the cardiac cycle. Experimental results on simulated phantom images confirm the accuracy and robustness of our method.
Integrated strain array for cellular mechanobiology studies
NASA Astrophysics Data System (ADS)
Simmons, C. S.; Sim, J. Y.; Baechtold, P.; Gonzalez, A.; Chung, C.; Borghi, N.; Pruitt, B. L.
2011-05-01
We have developed an integrated strain array for cell culture enabling high-throughput mechano-transduction studies. Biocompatible cell culture chambers were integrated with an acrylic pneumatic compartment and microprocessor-based control system. Each element of the array consists of a deformable membrane supported by a cylindrical pillar within a well. For user-prescribed waveforms, the annular region of the deformable membrane is pulled into the well around the pillar under vacuum, causing the pillar-supported region with cultured cells to be stretched biaxially. The optically clear device and pillar-based mechanism of operation enables imaging on standard laboratory microscopes. Straightforward fabrication utilizes off-the-shelf components, soft lithography techniques in polydimethylsiloxane and laser ablation of acrylic sheets. Proof of compatibility with basic biological assays and standard imaging equipment were accomplished by straining C2C12 skeletal myoblasts on the device for 6 h. At higher strains, cells and actin stress fibers realign with a circumferential preference.
Zhang, Li; Wu, Wei-Chun; Ma, Hong; Wang, Hao
2016-11-15
Layer-specific strain allows the assessment of the function of every layer of myocardium. To evaluate the changes of non-ST-segment elevation acute coronary syndrome(NSTE-ACS) patients with and without complex coronary artery disease(CAD) by layer-specific strain and determine if myocardial strain can identify complex CAD and assess the severity of coronary lesions as defined by Syntax score (SS). A total of 139 patients undergoing coronary angiography due to suspected NSTE-ACS were prospectively enrolled. Echocardiography was performed 1h before angiography. Global longitudinal strain (GLS), territorial longitudinal strain (TLS), global circumferential strain (GCS) and territorial circumferential strain (TCS) of the three layers of LV wall were assessed by two-dimensional (2D) speckle tracking echocardiography (STE) with layer-specific myocardial deformation quantitative analysis based on the perfusion territories of the three major coronary arteries in an 18-segment model of LV. SS was used for predicting the severity of coronary lesions in patients with complex CAD. 78 had complex CAD, 32 had 1- or 2-vessel disease and 29 had no significant coronary stenosis confirmed by coronary angiography. According to SS value, 78 complex CAD subjects were subdivided into three groups, 24 in group SS 1 (SS≤22), 26 in group SS 2 (SS 23-32) and 28 in group SS 3 (SS≥33). Compared to the other two groups without complex CAD, patients with NSTE-ACS due to complex CAD had worse function in all 3 myocardial layers assessed by GLS, TLS, GCS and TCS. Endocardial GLS and TLS (all, P<0.01) were most affected. The absolute differences between endocardial and epicardial GLS and TLS were lower in magnitude in patients with complex CAD than in those without (all, P<0.001), and the more complex of coronary lesion, the lower magnitude of the parameters(all, P<0.001). Endocardial GLS and TLS were closely correlated with SS value(r=-0.751 and r=-0.753, respectively; P<0.001). By receiver
Karimi, Alireza; Navidbakhsh, Mahdi; Haghighatnama, Maedeh; Haghi, Afsaneh Motevalli
2015-01-01
The skin, being a multi-layered material, is responsible for protecting the human body from the mechanical, bacterial, and viral insults. The skin tissue may display different mechanical properties according to the anatomical locations of a body. However, these mechanical properties in different anatomical regions and at different loading directions (axial and circumferential) of the mice body to date have not been determined. In this study, the axial and circumferential loads were imposed on the mice skin samples. The elastic modulus and maximum stress of the skin tissues were measured before the failure occurred. The nonlinear mechanical behavior of the skin tissues was also computationally investigated through a suitable constitutive equation. Hyperelastic material model was calibrated using the experimental data. Regardless of the anatomic locations of the mice body, the results revealed significantly different mechanical properties in the axial and circumferential directions and, consequently, the mice skin tissue behaves like a pure anisotropic material. The highest elastic modulus was observed in the back skin under the circumferential direction (6.67 MPa), while the lowest one was seen in the abdomen skin under circumferential loading (0.80 MPa). The Ogden material model was narrowly captured the nonlinear mechanical response of the skin at different loading directions. The results help to understand the isotropic/anisotropic mechanical behavior of the skin tissue at different anatomical locations. They also have implications for a diversity of disciplines, i.e., dermatology, cosmetics industry, clinical decision making, and clinical intervention.
Esophageal circumferential en bloc endoscopic submucosal dissection: assessment of a new technique.
Barret, Maximilien; Pratico, Carlos Alberto; Beuvon, Frédéric; Mangialavori, Luigi; Chryssostalis, Ariane; Camus, Marine; Chaussade, Stanislas; Prat, Frédéric
2013-10-01
Endoscopic esophageal piecemeal mucosectomy for high-grade dysplasia on Barrett's esophagus leads to suboptimal histologic evaluation, as well as recurrence on remaining mucosa. Circumferential en bloc mucosal resection would significantly improve the management of dysplastic Barrett's esophagus. Our aim was to describe a new method of esophageal circumferential endoscopic en bloc submucosal dissection (CESD) in a swine model. After submucosal injection, circumferential incision was performed at each end of the esophageal segment to be removed. Mechanical submucosal dissection was performed from the proximal to the distal incision, using a mucosectomy cap over the endoscope. The removed mucosal ring was retrieved. Clinical, endoscopic, and histologic data were prospectively collected. Esophageal CESD was conducted on 5 pigs. A median mucosal length of 6.5 cm (range, 4 to 8 cm) was removed in the lower third of the esophagus. The mean duration of the procedure was 36 minutes (range, 17 to 80 min). No procedure-related complication, including perforation, was observed. All animals exhibited a mild esophageal stricture at day 7, and a severe symptomatic stricture at day 14. Necropsy confirmed endoscopic findings with cicatricial fibrotic strictures. On histologic examination, an inflammatory cell infiltrate, diffuse fibrosis reaching the muscular layer, and incomplete reepithelialization were observed. CESD enables expeditious resection and thorough examination of large segments of esophageal mucosa in safe procedural conditions, but esophageal strictures occur in the majority of the cases. Efficient methods for stricture prevention are needed for this technique to be developed in humans.
Polsky, Yarom
2014-05-23
This entry contains raw data files from experiments performed on the Vulcan beamline at the Spallation Neutron Source at Oak Ridge National Laboratory using a pressure cell. Cylindrical granite and marble samples were subjected to confining pressures of either 0 psi or approximately 2500 psi and internal pressures of either 0 psi, 1500 psi or 2500 psi through a blind axial hole at the center of one end of the sample. The sample diameters were 1.5" and the sample lengths were 6". The blind hole was 0.25" in diameter and 3" deep. One set of experiments measured strains at points located circumferentially around the center of the sample with identical radii to determine if there was strain variability (this would not be expected for a homogeneous material based on the symmetry of loading). Another set of experiments measured load variation across the radius of the sample at a fixed axial and circumferential location. Raw neutron diffraction intensity files and experimental parameter descriptions are included.
An extensometer for global measurement of bone strain suitable for use in vivo in humans
NASA Technical Reports Server (NTRS)
Perusek, G. P.; Davis, B. L.; Sferra, J. J.; Courtney, A. C.; D'Andrea, S. E.
2001-01-01
An axial extensometer able to measure global bone strain magnitudes and rates encountered during physiological activity, and suitable for use in vivo in human subjects, is described. The extensometer uses paired capacitive sensors mounted to intraosseus pins and allows measurement of strain due to bending in the plane of the extensometer as well as uniaxial compression or tension. Data are presented for validation of the device against a surface-mounted strain gage in an acrylic specimen under dynamic four-point bending, with square wave and sinusoidal loading inputs up to 1500 mu epsilon and 20 Hz, representative of physiological strain magnitudes and frequencies. Pearson's correlation coefficient (r) between extensometer and strain gage ranged from 0.960 to 0.999. Mean differences between extensometer and strain gage ranged up to 15.3 mu epsilon. Errors in the extensometer output were directly proportional to the degree of bending that occurs in the specimen, however, these errors were predictable and less than 1 mu epsilon for the loading regime studied. The device is capable of tracking strain rates in excess of 90,000 mu epsilon/s.
Circumferential Ciliary Body Cysts Presenting as Acute Pigment Dispersion and Ocular Hypertension.
Sarıgül Sezenöz, Almila; Güngör, Sirel Gür; Kıratlı, Hayyam; Akman, Ahmet
2017-09-15
To report a case of circumferential neuroepithelial cyst of the ciliary body presenting with pigment dispersion (PD) and ocular hypertension. 48-year-old female patient presented with a complaint of pain in the left eye. On examination, visual acuity of the left eye was 0.9, and the intraocular pressure was 48 mmHg. Biomicroscopic anterior segment examination of the left eye revealed 4+ pigmented cells in the anterior chamber. Active PD from the pupillary region at 11 o'clock was noticed at the time of the examination. Ultrasound biomicroscopy demonstrated 360º cystic lesions of the ciliary body in the left eye. The patient was diagnosed as neuroepithelial cyst of the ciliary body. Our case is unique as it is the first case of circumferential neuroepithelial ciliary body cyst presenting with acute PD and ocular hypertension.
Three-dimensional circumferential liposuction of the overweight or obese upper arm.
Hong, Yoon Gi; Sim, Hyung Bo; Lee, Mu Young; Seo, Sang Won; Chang, Choong Hyun; Yeo, Kwan Koo; Kim, June-kyu
2012-06-01
Due to recent trends in liposuction, anatomic consideration of the body's fatty layers is essential. Based on this knowledge, a circumferential approach to achieving maximal aesthetic results is highlighted. In the upper arm, aspiration of fat from only the posterolateral region can result in skin flaccidity and disharmony of the overall balance of the upper arm contour. Different suction techniques were applied depending on the degree of fat accumulation. If necessary, the operation area was extended around the axillary and scapular regions to overcome the limitations of the traditional method and to achieve optimal effects. To maximize skin contracture and redraping, the authors developed three-dimensional circumferential liposuction (3D-CL) based on two concepts: circumferential aspiration of the upper arm, to which was applied different fluid infiltration and liposuction techniques in three anatomic compartments (anteromedial, anterolateral, and posterolateral), and extension of liposuction to the periaxillar and parascarpular areas. A total of 57 female patients underwent liposuction of their excess arm fat using this technique. The authors achieved their aesthetic goals of a straightened inferior brachial border and a more slender body contour. Complications occurred for five patients including irregularity, incision-site scar, and transient pigmentation. Through 3D-CL, the limitations of traditional upper arm liposuction were overcome, and a slender arm contour with a straightened inferior brachial border was produced. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at http://www.springer.com/00266.
NASA Astrophysics Data System (ADS)
Wang, Ziwei; Jiang, Xiong; Chen, Ti; Hao, Yan; Qiu, Min
2018-05-01
Simulating the unsteady flow of compressor under circumferential inlet distortion and rotor/stator interference would need full-annulus grid with a dual time method. This process is time consuming and needs a large amount of computational resources. Harmonic balance method simulates the unsteady flow in compressor on single passage grid with a series of steady simulations. This will largely increase the computational efficiency in comparison with the dual time method. However, most simulations with harmonic balance method are conducted on the flow under either circumferential inlet distortion or rotor/stator interference. Based on an in-house CFD code, the harmonic balance method is applied in the simulation of flow in the NASA Stage 35 under both circumferential inlet distortion and rotor/stator interference. As the unsteady flow is influenced by two different unsteady disturbances, it leads to the computational instability. The instability can be avoided by coupling the harmonic balance method with an optimizing algorithm. The computational result of harmonic balance method is compared with the result of full-annulus simulation. It denotes that, the harmonic balance method simulates the flow under circumferential inlet distortion and rotor/stator interference as precise as the full-annulus simulation with a speed-up of about 8 times.
NASA Astrophysics Data System (ADS)
Baba, Isa Abdullahi; Hincal, Evren
2017-05-01
In this article we studied an epidemic model consisting of two strains with different types of incidence rates; bilinear and non-monotone. The model consists of four equilibrium points: disease-free equilibrium, endemic with respect to strain 1, endemic with respect to strain 2, and endemic with respect to both strains. The global stability analysis of the equilibrium points was carried out through the use of Lyapunov functions. Two basic reproduction ratios R 1 0 and R 2 0 are found, and we have shown that if both are less than one, the disease dies out, and if both are greater than one epidemic occurs. Furthermore, epidemics occur with respect to any strain with a basic reproduction ratio greater than one and disease dies out with respect to any strain with a basic reproduction ratio less than one. It was also shown that any strain with highest basic reproduction ratio will automatically outperform the other strain, thereby eliminating it. Numerical simulations were carried out to support the analytic result and to show the effect of the parameter k in the non-monotone incidence rate, which describes the psychological effect of general public towards infection.
Unemo, Magnus; Golparian, Daniel; Sánchez-Busó, Leonor; Grad, Yonatan; Jacobsson, Susanne; Ohnishi, Makoto; Lahra, Monica M; Limnios, Athena; Sikora, Aleksandra E; Wi, Teodora; Harris, Simon R
2016-11-01
Gonorrhoea and MDR Neisseria gonorrhoeae remain public health concerns globally. Enhanced, quality-assured, gonococcal antimicrobial resistance (AMR) surveillance is essential worldwide. The WHO global Gonococcal Antimicrobial Surveillance Programme (GASP) was relaunched in 2009. We describe the phenotypic, genetic and reference genome characteristics of the 2016 WHO gonococcal reference strains intended for quality assurance in the WHO global GASP, other GASPs, diagnostics and research worldwide. The 2016 WHO reference strains (n = 14) constitute the eight 2008 WHO reference strains and six novel strains. The novel strains represent low-level to high-level cephalosporin resistance, high-level azithromycin resistance and a porA mutant. All strains were comprehensively characterized for antibiogram (n = 23), serovar, prolyliminopeptidase, plasmid types, molecular AMR determinants, N. gonorrhoeae multiantigen sequence typing STs and MLST STs. Complete reference genomes were produced using single-molecule PacBio sequencing. The reference strains represented all available phenotypes, susceptible and resistant, to antimicrobials previously and currently used or considered for future use in gonorrhoea treatment. All corresponding resistance genotypes and molecular epidemiological types were described. Fully characterized, annotated and finished references genomes (n = 14) were presented. The 2016 WHO gonococcal reference strains are intended for internal and external quality assurance and quality control in laboratory investigations, particularly in the WHO global GASP and other GASPs, but also in phenotypic (e.g. culture, species determination) and molecular diagnostics, molecular AMR detection, molecular epidemiology and as fully characterized, annotated and finished reference genomes in WGS analysis, transcriptomics, proteomics and other molecular technologies and data analysis. © The Author 2016. Published by Oxford University Press on behalf of the
Strain-Based Design Methodology of Large Diameter Grade X80 Linepipe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lower, Mark D.
2014-04-01
Continuous growth in energy demand is driving oil and natural gas production to areas that are often located far from major markets where the terrain is prone to earthquakes, landslides, and other types of ground motion. Transmission pipelines that cross this type of terrain can experience large longitudinal strains and plastic circumferential elongation as the pipeline experiences alignment changes resulting from differential ground movement. Such displacements can potentially impact pipeline safety by adversely affecting structural capacity and leak tight integrity of the linepipe steel. Planning for new long-distance transmission pipelines usually involves consideration of higher strength linepipe steels because theirmore » use allows pipeline operators to reduce the overall cost of pipeline construction and increase pipeline throughput by increasing the operating pressure. The design trend for new pipelines in areas prone to ground movement has evolved over the last 10 years from a stress-based design approach to a strain-based design (SBD) approach to further realize the cost benefits from using higher strength linepipe steels. This report presents an overview of SBD for pipelines subjected to large longitudinal strain and high internal pressure with emphasis on the tensile strain capacity of high-strength microalloyed linepipe steel. The technical basis for this report involved engineering analysis and examination of the mechanical behavior of Grade X80 linepipe steel in both the longitudinal and circumferential directions. Testing was conducted to assess effects on material processing including as-rolled, expanded, and heat treatment processing intended to simulate coating application. Elastic-plastic and low-cycle fatigue analyses were also performed with varying internal pressures. Proposed SBD models discussed in this report are based on classical plasticity theory and account for material anisotropy, triaxial strain, and microstructural damage effects
Sokolis, Dimitrios P; Savva, Giannis D; Papadodima, Stavroula A; Kourkoulis, Stavros K
2017-03-01
The biomechanical response of the human aorta varies with axial location, but little is known about the respective variation of residual strains. Such data are available for common lab animals, but in the traditional opening angle measurement the aorta is considered as an ideal cylinder and average residual strains are measured, so that the spatial variations of local residual strains are not determined. The present study provides opening angle and residual strain data throughout the course and around the circumference of the aorta harvested during autopsy. Opening angle showed notable topographical variation; the highest value was at the top of aortic arch, declining abruptly toward the ascending aorta and to a near-constant value in the descending aorta, and rising in the abdominal aorta. The variation of curvature and of external but not internal residual stretch resembled that of opening angle. Extensive residual stress and wall thickness differences were evidenced among quadrants, with the more pre-stressed being also the thicker quadrants. Gender had overall minor effects, but aging led to increased parameters, occurring earlier in the distal aorta but at later stages becoming predominant proximally. Differences in caliber were pronounced in older subjects, unlike those in opening angle, residual stretches, and thickness that were striking in middle-aged subjects. By contrast, curvature decreased with aging in relation to the smaller percentwise opening angle differences. Detailed knowledge of the zero-stress/no-load geometry of the human aortic wall is critical for an in-depth understanding of aortic physiology, while providing the basis for comparison with disease. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chadwick, W.W.; Howard, K.A.
1991-01-01
Maps of the eruptive vents on the active shield volcanoes of Fernandina and Isabela islands, Galapagos, made from aerial photographs, display a distinctive pattern that consists of circumferential eruptive fissures around the summit calderas and radial fissures lower on the flanks. On some volcano flanks either circumferential or radial eruptions have been dominant in recent time. The location of circumferential vents outside the calderas is independent of caldera-related normal faults. The eruptive fissures are the surface expression of dike emplacement, and the dike orientations are interpreted to be controlled by the state of stress in the volcano. Very few subaerial volcanoes display a pattern of fissures similar to that of the Galapagos volcanoes. Some seamounts and shield volcanoes on Mars morphologically resemble the Galapagos volcanoes, but more specific evidence is needed to determine if they also share common structure and eruptive style. ?? 1991 Springer-Verlag.
Han, Chongxu; Tang, Hui; Ren, Chuanli; Zhu, Xiaoping; Han, Dongsheng
2016-01-01
Pandemic Vibrio parahaemolyticus is an emerging public health concern as it has caused numerous gastroenteritis outbreaks worldwide. Currently, the absence of a global overview of the phenotypic and molecular characteristics of pandemic strains restricts our overall understanding of these strains, especially for environmental strains. To generate a global picture of the sero-prevalence and genetic diversity of pandemic V. parahaemolyticus, pandemic isolates from worldwide collections were selected and analyzed in this study. After a thorough analysis, we found that the pandemic isolates represented 49 serotypes, which are widely distributed in 22 countries across four continents (Asia, Europe, America and Africa). All of these serotypes were detected in clinical isolates but only nine in environmental isolates. O3:K6 was the most widely disseminated serotype, followed by O3:KUT, while the others were largely restricted to certain countries. The countries with the most abundant pandemic serotypes were China (26 serotypes), India (24 serotypes), Thailand (15 serotypes) and Vietnam (10 serotypes). Based on MLST analysis, 14 sequence types (STs) were identified among the pandemic strains, nine of which fell within clonal complex (CC) 3. ST3 and ST305 were the only two STs that have been reported in environmental pandemic strains. Pandemic ST3 has caused a wide range of infections in as many as 16 countries. Substantial serotypic diversity was mainly observed among isolates within pandemic ST3, including as many as 12 combinations of O/K serotypes. At the allele level, the dtdS and pntA, two loci that perfectly conserved in CC3, displayed a degree of polymorphism in some pandemic strains. In conclusion, we provide a comprehensive understanding of sero-prevalence and genetic differentiation of clinical and environmental pandemic isolates collected from around the world. Although, further studies are needed to delineate the specific mechanisms by which the pandemic
Sohns, Christian; Bergau, Leonard; Seegers, Joachim; Lüthje, Lars; Vollmann, Dirk; Zabel, Markus
2014-10-01
In ablation of atrial fibrillation, the single-ring method aims for isolation of the posterior wall of the left atrium (LA) including the pulmonary veins (PVs) but avoiding posterior LA lesions. The aim of this randomized prospective study was to evaluate safety and efficacy of remote magnetic navigation (RMN)-guided single-ring ablation strategy as compared to standard RMN-guided circumferential PV ablation (PVA). Eighty consecutive patients undergoing PVA were enrolled prospectively and randomized equally into two study groups. RMN using the Stereotaxis system and open-irrigated 3.5-mm ablation catheters were used with a 3D mapping system in all procedures. Forty patients underwent RMN-guided single-ring ablation, and 40 patients received RMN-guided circumferential PVA. In the circumferential group, 3.3 ± 1.1 PVs were successfully isolated at the end of the procedure as compared to 3.1 ± 1.3 in the single-ring (box) group (p=0.38). All patients in the box group required additional posterior lesions in order to achieve electrical isolation of the PVs. Single-ring ablation was associated with longer procedure duration (p=0.01) and ablation time (p=0.001). After a single procedure, the proportion of patients free of any atrial tachycardia (AT)/atrial fibrillation (AF) episode at 12-month follow-up was 57 % in the box group and 58 % in the circ group. Using RMN, only minor complications have been observed. RMN-guided single-ring PVA provides comparable acute and long-term success rates as compared to RMN-guided circumferential PVA but requires additional posterior lesions to achieve PV isolation and increased procedure and ablation time. Procedural complication rates are low when using RMN.
deCamp, Allan; Hraber, Peter; Bailer, Robert T.; Seaman, Michael S.; Ochsenbauer, Christina; Kappes, John; Gottardo, Raphael; Edlefsen, Paul; Self, Steve; Tang, Haili; Greene, Kelli; Gao, Hongmei; Daniell, Xiaoju; Sarzotti-Kelsoe, Marcella; Gorny, Miroslaw K.; Zolla-Pazner, Susan; LaBranche, Celia C.; Mascola, John R.; Korber, Bette T.
2014-01-01
ABSTRACT Standardized assessments of HIV-1 vaccine-elicited neutralizing antibody responses are complicated by the genetic and antigenic variability of the viral envelope glycoproteins (Envs). To address these issues, suitable reference strains are needed that are representative of the global epidemic. Several panels have been recommended previously, but no clear answers have been available on how many and which strains are best suited for this purpose. We used a statistical model selection method to identify a global panel of reference Env clones from among 219 Env-pseudotyped viruses assayed in TZM-bl cells with sera from 205 HIV-1-infected individuals. The Envs and sera were sampled globally from diverse geographic locations and represented all major genetic subtypes and circulating recombinant forms of the virus. Assays with a panel size of only nine viruses adequately represented the spectrum of HIV-1 serum neutralizing activity seen with the larger panel of 219 viruses. An optimal panel of nine viruses was selected and augmented with three additional viruses for greater genetic and antigenic coverage. The spectrum of HIV-1 serum neutralizing activity seen with the final 12-virus panel closely approximated the activity seen with subtype-matched viruses. Moreover, the final panel was highly sensitive for detection of many of the known broadly neutralizing antibodies. For broader assay applications, all 12 Env clones were converted to infectious molecular clones using a proviral backbone carrying a Renilla luciferase reporter gene (Env.IMC.LucR viruses). This global panel should facilitate highly standardized assessments of vaccine-elicited neutralizing antibodies across multiple HIV-1 vaccine platforms in different parts of the world. IMPORTANCE An effective HIV-1 vaccine will need to overcome the extraordinary genetic variability of the virus, where most variation occurs in the viral envelope glycoproteins that are the sole targets for neutralizing antibodies
deCamp, Allan; Hraber, Peter; Bailer, Robert T; Seaman, Michael S; Ochsenbauer, Christina; Kappes, John; Gottardo, Raphael; Edlefsen, Paul; Self, Steve; Tang, Haili; Greene, Kelli; Gao, Hongmei; Daniell, Xiaoju; Sarzotti-Kelsoe, Marcella; Gorny, Miroslaw K; Zolla-Pazner, Susan; LaBranche, Celia C; Mascola, John R; Korber, Bette T; Montefiori, David C
2014-03-01
Standardized assessments of HIV-1 vaccine-elicited neutralizing antibody responses are complicated by the genetic and antigenic variability of the viral envelope glycoproteins (Envs). To address these issues, suitable reference strains are needed that are representative of the global epidemic. Several panels have been recommended previously, but no clear answers have been available on how many and which strains are best suited for this purpose. We used a statistical model selection method to identify a global panel of reference Env clones from among 219 Env-pseudotyped viruses assayed in TZM-bl cells with sera from 205 HIV-1-infected individuals. The Envs and sera were sampled globally from diverse geographic locations and represented all major genetic subtypes and circulating recombinant forms of the virus. Assays with a panel size of only nine viruses adequately represented the spectrum of HIV-1 serum neutralizing activity seen with the larger panel of 219 viruses. An optimal panel of nine viruses was selected and augmented with three additional viruses for greater genetic and antigenic coverage. The spectrum of HIV-1 serum neutralizing activity seen with the final 12-virus panel closely approximated the activity seen with subtype-matched viruses. Moreover, the final panel was highly sensitive for detection of many of the known broadly neutralizing antibodies. For broader assay applications, all 12 Env clones were converted to infectious molecular clones using a proviral backbone carrying a Renilla luciferase reporter gene (Env.IMC.LucR viruses). This global panel should facilitate highly standardized assessments of vaccine-elicited neutralizing antibodies across multiple HIV-1 vaccine platforms in different parts of the world. An effective HIV-1 vaccine will need to overcome the extraordinary genetic variability of the virus, where most variation occurs in the viral envelope glycoproteins that are the sole targets for neutralizing antibodies. Efforts to elicit
Neustein, Rebecca F; Beck, Allen D
2017-11-01
This study compares the long-term efficacy of circumferential trabeculotomy to that of conventional angle surgeries in primary congenital glaucoma (PCG), as judged by glaucoma and visual outcomes. Retrospective observational case series. Setting: Emory Eye Center, Atlanta, Georgia. This was a single-institution retrospective study involving children with PCG who underwent circumferential trabeculotomy, standard trabeculotomy, or goniotomy with ≥2-year follow-up. Postoperative success (intraocular pressure [IOP] < 22 mm Hg ± glaucoma medications, without glaucoma progression/additional IOP-lowering surgery), Snellen-equivalent visual acuity (VA), and IOP at last follow-up. Kaplan-Meier method estimated the probability of glaucoma control vs time postoperatively, and values were compared between angle surgery cohorts using Wilcoxon signed rank tests, Mann-Whitney U tests, and Fisher exact tests. Included were 58 eyes (33 children) after circumferential trabeculotomy and 42 eyes (27 children) after standard trabeculotomy/goniotomy, with mean follow-up of 7.2 ± 4.0 and 8.2 ± 4.5 years, respectively. Postoperative success at last follow-up in the circumferential vs conventional cohorts was 81% (47 of 58 eyes) vs 31% (13 of 42 eyes) (P < .0001). At last follow-up, the circumferential cohort had better median VA than the conventional cohort (20/30 (interquartile range [IQR] 20/25 to 20/70) vs 20/70 (IQR 20/40 to 20/200), P = .009), required fewer glaucoma medications (0.55 ± 1.2 vs 1.61 ± 1.51, P < .0001), had lower IOP in first operated eye (15.2 ± 3.6 vs 18.2 ± 7.0, P = .048), and had comparable incidence of devastating complications (P = .065). In this retrospective study, circumferential trabeculotomy afforded better long-term success and visual outcomes than conventional angle surgery for children with PCG. Copyright © 2017 Elsevier Inc. All rights reserved.
Improved circumferential shaft seal for aircraft gear transmissions
NASA Technical Reports Server (NTRS)
Ludwig, L. P.; Strom, T. N.
1973-01-01
Operation under simulated aircraft transmission conditions of speeds to 2850 m/min (9350 ft/min), lubricant temperatures to 394 K (250 F), shaft radial runouts to 0.254 mm (0.010 in.) F.I.R. (full indicator reading), and pressure differentials to 1.03 N/cm2 (1.5 psi) revealed that conventional circumferential seals leaked excessively. Modifying the conventional seal by adding helical grooves to the seal bore reduced leakage rates to within the acceptable level of 10 cm3/hr. The leakage rate of this modified seal was not significantly affected by lubricant flooding or by shaft radial runout.
Abdulrahman, Randa M; Delgado, Victoria; Hoftijzer, Hendrieke C; Ng, Arnold C T; Ewe, See Hooi; Marsan, Nina Ajmone; Holman, Eduard R; Hovens, Guido C; Corssmit, Eleonora P; Romijn, Johannes A; Bax, Jeroen J; Smit, Johannes W A
2011-05-01
The cardiovascular effects of transitions from exogenous subclinical hyperthyroidism to short-term overt hypothyroidism in patients treated for differentiated thyroid carcinoma remain unclear. The present study aims at evaluating the changes in multidirectional myocardial strain using two-dimensional (2D) speckle tracking during this controlled transition from exogenous subclinical hyperthyroidism to overt hypothyroidism. The study included 14 patients with differentiated thyroid carcinoma on thyrotropin suppressive thyroxine substitution who were subsequently withdrawn from thyroxine for 4 weeks. Cardiac function was assessed by 2D speckle tracking echocardiography before and 1 and 4 weeks after withdrawal and compared with values obtained in a control group of 24 individuals. At baseline, the left ventricular dimensions were significantly higher in patients as compared with controls. Using 2D speckle tracking imaging, the patients had significantly impaired baseline myocardial systolic function in the circumferential (-16.0% ± 2.1% vs. -19.2% ± 3.0%, p = 0.001) and longitudinal (-17.1% ± 2.5% vs. -19.7% ± 3.0%, p = 0.001) directions as compared with controls. Withdrawal of thyroid hormone did not induce significant changes in left ventricular dimensions or systolic function. During the transition from exogenous subclinical hyperthyroidism to overt hypothyroidism, a significant improvement in circumferential and longitudinal systolic shortening was observed and returned to abnormal values when the patients were overt hypothyroid (circumferential strain: from -16.0% ± 2.1% to -18.6% ± 1.9% and -14.7% ± 2.8%, p < 0.005; longitudinal strain: from -17.1% ± 2.5% to -18.8% ± 1.4% and -16.3% ± 1.3%, p < 0.005). A U-shaped relationship between a range of thyroid hormone levels (from hyper- to hypothyroid concentrations) and myocardial strains was observed. The clinical consequences of these findings remain
Kim, Kyung Hwan; Park, Min Jung; Lim, Joon Seok; Kim, Nam Kyu; Min, Byung Soh; Ahn, Joong Bae; Kim, Tae Il; Kim, Ho Geun; Koom, Woong Sub
2016-04-01
To identify patients who are at a higher risk of pathologic circumferential resection margin involvement using preoperative magnetic resonance imaging. Between October 2008 and November 2012, 165 patients with locally advanced rectal cancer (cT4 or cT3 with <2 mm distance from tumour to mesorectal fascia) who received preoperative chemoradiotherapy were analysed. The morphologic patterns on post-chemoradiotherapy magnetic resonance imaging were categorized into five patterns from Pattern A (most-likely negative pathologic circumferential resection margin) to Pattern E (most-likely positive pathologic circumferential resection margin). In addition, the location of mesorectal fascia involvement was classified as lateral, posterior and anterior. The diagnostic accuracy of the morphologic criteria was calculated using receiver operating characteristic curve analysis. Pathologic circumferential resection margin involvement was identified in 17 patients (10.3%). The diagnostic accuracy of predicting pathologic circumferential resection margin involvement was 0.73 using the five-scale magnetic resonance imaging pattern. The sensitivity, specificity, positive predictive value and negative predictive value for predicting pathologic circumferential resection margin involvement were 76.5, 65.5, 20.3 and 96.0%, respectively, when cut-off was set between Patterns C and D. On multivariate logistic regression, the magnetic resonance imaging patterns D and E (P= 0.005) and posterior or lateral mesorectal fascia involvement (P= 0.017) were independently associated with increased probability of pathologic circumferential resection margin involvement. The rate of pathologic circumferential resection margin involvement was 30.0% when the patient had Pattern D or E with posterior or lateral mesorectal fascia involvement. Patients who are at a higher risk of pathologic circumferential resection margin involvement can be identified using preoperative magnetic resonance imaging although
Complete 360° circumferential SSOCT gonioscopy of the iridocorneal angle
NASA Astrophysics Data System (ADS)
McNabb, Ryan P.; Kuo, Anthony N.; Izatt, Joseph A.
2014-02-01
The ocular iridocorneal angle is generally an optically inaccessible area when viewed directly through the cornea due to the high angle of incidence required and the large index of refraction difference between air and cornea (nair = 1.000 and ncornea = 1.376) resulting in total internal reflection. Gonioscopy allows for viewing of the angle by removing the aircornea interface through the use of a special contact lens on the eye. Gonioscopy is used clinically to visualize the angle directly but only en face. Optical coherence tomography (OCT) has been used to image the angle and deeper structures via an external approach. Typically, this imaging technique is performed by utilizing a conventional anterior segment OCT scanning system. However, instead of imaging the apex of the cornea, either the scanner or the subject is tilted such that the corneoscleral limbus is orthogonal to the optical axis of the scanner requiring multiple volumes to obtain complete circumferential coverage of the ocular angle. We developed a novel gonioscopic OCT (GOCT) system that images the entire ocular angle within a single volume via an "internal" approach through the use of a custom radially symmetric gonioscopic contact lens. We present, to our knowledge, the first complete 360° circumferential volumes of the iridocorneal angle from a direct, internal approach.
Skin resurfacing in a circumferential full thickness burn to the penis: lessons learnt.
Jabir, Shehab; Frew, Quentin; Thompson, Richard; Dziewulski, Peter
2013-08-13
A circumferential full-thickness burn to the penis is a rarely encountered injury. However, when it does occur, it proves a management challenge to the plastic and burns surgeon in terms of reconstruction. This is due to the need of not only regaining adequate function of the organ, but also because of the need for a pleasing aesthetic outcome. Split-skin grafts have been utilised successfully to resurface full thickness burns of the penis and have given good results. Yet the success of split-skin grafts, especially those applied to an anatomically challenging region of the body such as the penis, depends on a number of carefully thought-out steps. We discuss the case of a circumferential full-thickness burn to the penis which was treated with split-skin grafting and highlight important pitfalls that the plastic and burns surgeon need to be aware of to ensure a successful outcome.
Saturn S-11 Production Operations Techniques, Production Welding. Volume 3: Circumferential Welding
NASA Technical Reports Server (NTRS)
Abel, D. G.
1970-01-01
Special processes and techniques are described for the circumferential welding of Saturn 2 cylinder and bulkhead assemblies to complete the LO2 and LH2 tankage and to maximize efficiency and personnel performance during S-2 follow-on or restart activities. The processes are only applicable to aluminum alloys within the 2000 series.
Circumferential suture technique for esophageal transection to treat esophageal variceal bleeding.
Jeng, L B; Chen, M F
1993-01-01
The EEA stapler has been used routinely for esophageal transection to treat esophageal variceal bleeding for some time. It carries the risk of postoperative leakage and is not suitable in those cases receiving recent sclerotherapy. The circumferential suture technique presented in this paper can be used in any situation requiring esophageal transection. It has been utilized by us in twenty-two emergent cases with good results.
de Waal, Koert; Phad, Nilkant
2018-03-01
Two-dimensional speckle tracking echocardiography is an emerging technique for analyzing cardiac function in newborns. Strain is a highly reliable and reproducible parameter, and reference values have been established for term and preterm newborns. Its implementation into clinical practice has been slow, partly due to lack of inter-vendor consistency. Our aim was to compare recent versions of Philips and Tomtec speckle tracking software for deformation and semiautomated volume and area measurements in neonatal intensive care patients. Longitudinal and circumferential deformation and cavity dimensions (volume, area) were determined off line from apical and short-axis images in 50 consecutive newborns with a median birthweight of 760 g (range 460-3200 g). Absolute mean endocardial global longitudinal strain measurements were similar between vendors, but with wide limits of agreement (Philips -18.9 [2.1]%, Tomtec -18.6 [2.5]%, bias -0.3 [1.7]%, and limits of agreement -3.6%-3.1%). Longitudinal strain rate and circumferential measurements showed poor correlation. All volume and area measurements correlated well between the vendors, but with significant bias. Global longitudinal strain measurements compared well between vendors but wide limits of agreement, suggesting that longitudinal measurements are preferred using similar hardware and software. © 2017, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Wang, Bin; Shao, Yanchun; Chen, Tao; Chen, Wanping; Chen, Fusheng
2015-12-01
Acetobacter pasteurianus (Ap) CICC 20001 and CGMCC 1.41 are two acetic acid bacteria strains that, because of their strong abilities to produce and tolerate high concentrations of acetic acid, have been widely used to brew vinegar in China. To globally understand the fermentation characteristics, acid-tolerant mechanisms and genetic stabilities, their genomes were sequenced. Genomic comparisons with 9 other sequenced Ap strains revealed that their chromosomes were evolutionarily conserved, whereas the plasmids were unique compared with other Ap strains. Analysis of the acid-tolerant metabolic pathway at the genomic level indicated that the metabolism of some amino acids and the known mechanisms of acetic acid tolerance, might collaboratively contribute to acetic acid resistance in Ap strains. The balance of instability factors and stability factors in the genomes of Ap CICC 20001 and CGMCC 1.41 strains might be the basis for their genetic stability, consistent with their stable industrial performances. These observations provide important insights into the acid resistance mechanism and the genetic stability of Ap strains and lay a foundation for future genetic manipulation and engineering of these two strains.
Wang, Bin; Shao, Yanchun; Chen, Tao; Chen, Wanping; Chen, Fusheng
2015-12-22
Acetobacter pasteurianus (Ap) CICC 20001 and CGMCC 1.41 are two acetic acid bacteria strains that, because of their strong abilities to produce and tolerate high concentrations of acetic acid, have been widely used to brew vinegar in China. To globally understand the fermentation characteristics, acid-tolerant mechanisms and genetic stabilities, their genomes were sequenced. Genomic comparisons with 9 other sequenced Ap strains revealed that their chromosomes were evolutionarily conserved, whereas the plasmids were unique compared with other Ap strains. Analysis of the acid-tolerant metabolic pathway at the genomic level indicated that the metabolism of some amino acids and the known mechanisms of acetic acid tolerance, might collaboratively contribute to acetic acid resistance in Ap strains. The balance of instability factors and stability factors in the genomes of Ap CICC 20001 and CGMCC 1.41 strains might be the basis for their genetic stability, consistent with their stable industrial performances. These observations provide important insights into the acid resistance mechanism and the genetic stability of Ap strains and lay a foundation for future genetic manipulation and engineering of these two strains.
NASA Astrophysics Data System (ADS)
Wu, Lei; Xie, Huikai
2008-02-01
This paper reports the design, fabrication and measurements of a dual-reflective, single-crystal silicon based micromirror that can perform full circumferential scanning (FCS) for endoscopic optical coherence tomography (EOCT). In the proposed FCS-EOCT probe, two optical fibers are used to deliver light beams to either surface of the micromirror, which can rotate +/-45° (or 90°) and thus a 180° optical scanning is obtained from each mirror surface, resulting in full circumferential scans. A novel surface- and bulk-combined micromachining process based on SOI wafers is developed for fabricating the dual reflective micromirror. The single-crystal-silicon device layer of SOI wafers is used for mirror flatness, and Al is coated on both sides for high reflectivity. With one light beam delivered to each mirror surface, full 360° scans have been observed. Other measured data include the resonant frequency: 328Hz, radius of curvatures: - 124 mm (front surface) and 127 mm (back surface), and the reflectances: 81.3% (front surface) and 79.0% (back surface).
2014-01-01
Salmonella enterica serovar Enteritidis is one of the important causes of bacterial food-borne gastroenteritis worldwide. Field strains of S. Enteritidis are relatively genetically homogeneous; however, they show extensive phenotypic diversity and differences in virulence potential. RNA sequencing (RNA-Seq) was used to characterize differences in the global transcriptome between several genetically similar but phenotypically diverse poultry-associated field strains of S. Enteritidis grown in laboratory medium at avian body temperature (42°C). These S. Enteritidis strains were previously characterized as high-pathogenicity (HP; n = 3) and low-pathogenicity (LP; n = 3) strains based on both in vitro and in vivo virulence assays. Using the negative binomial distribution-based statistical tools edgeR and DESeq, 252 genes were identified as differentially expressed in LP strains compared with their expression in the HP strains (P < 0.05). A majority of genes (235, or 93.2%) showed significantly reduced expression, whereas a few genes (17, or 6.8%) showed increased expression in all LP strains compared with HP strains. LP strains showed a unique transcriptional profile that is characterized by significantly reduced expression of several transcriptional regulators and reduced expression of genes involved in virulence (e.g., Salmonella pathogenicity island 1 [SPI-1], SPI-5, and fimbrial and motility genes) and protection against osmotic, oxidative, and other stresses, such as iron-limiting conditions commonly encountered within the host. Several functionally uncharacterized genes also showed reduced expression. This study provides a first concise view of the global transcriptional differences between field strains of S. Enteritidis with various levels of pathogenicity, providing the basis for future functional characterization of several genes with potential roles in virulence or stress regulation of S. Enteritidis. PMID:24271167
Tibayan, Frederick A; Lai, David T M; Timek, Tomasz A; Dagum, Paul; Liang, David; Zasio, Mary K; Daughters, George T; Miller, D Craig; Ingels, Neil B
2003-05-01
Functional mitral regurgitation (FMR) is increasingly recognized as a left ventricular (LV) disease. Dilated cardiomyopathy (DCM) is commonly accompanied by FMR and reduction of LV torsion. Therapeutic targets for DCM include LV size reduction, altered LV shape, elimination of MR, and increasing LV torsion. It was hypothesized that, in addition to increasing LV size, DCM with FMR would alter normal LV shape and reduce and alter the direction of principal strains across the LV wall. This hypothesis was tested by measuring changes in epicardial and endocardial 2-D principal strains and regional radii of curvature accompanying tachycardia-induced cardiomyopathy in ovine hearts. Radio-opaque marker arrays were implanted into the left ventricle of eight sheep, including one subepicardial triangle and one subendocardial triangle in the anterior wall of the left ventricle. At one week postoperatively, biplane videofluoroscopy was used to determine marker dynamics. Rapid ventricular pacing was then instituted until FMR and signs of heart failure developed, and fluoroscopy was repeated. Circumferential LV radii of curvature were determined from marker triplets. DCM changed the normal epicardial oval LV cross-section to a more circular configuration. The endocardium maintained its normal circular shape as the left ventricle dilated. Deformations of the triangles from end-diastole to end-systole were determined, and the magnitude and direction of 2-D principal strains calculated. DCM was associated with decreased magnitude of both epicardial (-0.095 +/- 0.055 versus -0.040 +/- 0.032, p = 0.006) and endocardial (-0.117 +/- 0.047 versus -0.073 +/- 0.037, p = 0.023) principal strains. DCM reduced the angle of epicardial but not endocardial principal strain. DCM with FMR is associated with LV dilation, circularization of the normally oval equatorial circumferential LV epicardium, transmural reduction in principal strain, and decrease in angle of principal epicardial strain. These
Skin resurfacing in a circumferential full thickness burn to the penis: lessons learnt
Jabir, Shehab; Frew, Quentin; Thompson, Richard; Dziewulski, Peter
2013-01-01
A circumferential full-thickness burn to the penis is a rarely encountered injury. However, when it does occur, it proves a management challenge to the plastic and burns surgeon in terms of reconstruction. This is due to the need of not only regaining adequate function of the organ, but also because of the need for a pleasing aesthetic outcome. Split-skin grafts have been utilised successfully to resurface full thickness burns of the penis and have given good results. Yet the success of split-skin grafts, especially those applied to an anatomically challenging region of the body such as the penis, depends on a number of carefully thought-out steps. We discuss the case of a circumferential full-thickness burn to the penis which was treated with split-skin grafting and highlight important pitfalls that the plastic and burns surgeon need to be aware of to ensure a successful outcome. PMID:23946511
Abdallah, Abdallah M.; Hill-Cawthorne, Grant A.; Otto, Thomas D.; Coll, Francesc; Guerra-Assunção, José Afonso; Gao, Ge; Naeem, Raeece; Ansari, Hifzur; Malas, Tareq B.; Adroub, Sabir A.; Verboom, Theo; Ummels, Roy; Zhang, Huoming; Panigrahi, Aswini Kumar; McNerney, Ruth; Brosch, Roland; Clark, Taane G.; Behr, Marcel A.; Bitter, Wilbert; Pain, Arnab
2015-01-01
Although Bacillus Calmette-Guérin (BCG) vaccines against tuberculosis have been available for more than 90 years, their effectiveness has been hindered by variable protective efficacy and a lack of lasting memory responses. One factor contributing to this variability may be the diversity of the BCG strains that are used around the world, in part from genomic changes accumulated during vaccine production and their resulting differences in gene expression. We have compared the genomes and transcriptomes of a global collection of fourteen of the most widely used BCG strains at single base-pair resolution. We have also used quantitative proteomics to identify key differences in expression of proteins across five representative BCG strains of the four tandem duplication (DU) groups. We provide a comprehensive map of single nucleotide polymorphisms (SNPs), copy number variation and insertions and deletions (indels) across fourteen BCG strains. Genome-wide SNP characterization allowed the construction of a new and robust phylogenic genealogy of BCG strains. Transcriptional and proteomic profiling revealed a metabolic remodeling in BCG strains that may be reflected by altered immunogenicity and possibly vaccine efficacy. Together, these integrated-omic data represent the most comprehensive catalogue of genetic variation across a global collection of BCG strains. PMID:26487098
Angeli, T R; O'Grady, G; Du, P; Paskaranandavadivel, N; Pullan, A J; Bissett, I P; Cheng, L K
2013-05-01
Slow-waves modulate the pattern of small intestine contractions. However, the large-scale spatial organization of intestinal slow-wave pacesetting remains uncertain because most previous studies have had limited resolution. This study applied high-resolution (HR) mapping to evaluate intestinal pacesetting mechanisms and propagation patterns in vivo. HR serosal mapping was performed in anesthetized pigs using flexible arrays (256 electrodes; 32 × 8; 4 mm spacing), applied along the jejunum. Slow-wave propagation patterns, frequencies, and velocities were calculated. Slow-wave initiation sources were identified and analyzed by animation and isochronal activation mapping. Analysis comprised 32 recordings from nine pigs (mean duration 5.1 ± 3.9 min). Slow-wave propagation was analyzed, and a total of 26 sources of slow-wave initiation were observed and classified as focal pacemakers (31%), sites of functional re-entry (23%) and circumferential re-entry (35%), or indeterminate sources (11%). The mean frequencies of circumferential and functional re-entry were similar (17.0 ± 0.3 vs 17.2 ± 0.4 cycle min(-1) ; P = 0.5), and greater than that of focal pacemakers (12.7 ± 0.8 cycle min(-1) ; P < 0.001). Velocity was anisotropic (12.9 ± 0.7 mm s(-1) circumferential vs 9.0 ± 0.7 mm s(-1) longitudinal; P < 0.05), contributing to the onset and maintenance of re-entry. This study has shown multiple patterns of slow-wave initiation in the jejunum of anesthetized pigs. These results constitute the first description and analysis of circumferential re-entry in the gastrointestinal tract and functional re-entry in the in vivo small intestine. Re-entry can control the direction, pattern, and frequency of slow-wave propagation, and its occurrence and functional significance merit further investigation. © 2013 Blackwell Publishing Ltd.
Fan, Lihong; Ge, Zhaogang; Zhang, Chen; Li, Jia; Yu, Zefeng; Dang, Xiaoqian; Wang, Kunzheng
2015-01-01
The purpose of this meta-analysis and systematic review was to identify and assess whether circumferential electrocautery is useful for improving outcomes after primary total knee replacement(TKR). We searched MEDLINE, EMBASE, PubMed, SpringerLink, Web of Knowledge, OVID CINAHL, OVID EBM and Google Scholar and included articles published through January 2014. A total of 6 articles met the inclusion criteria. Of the 776 cases included in the analysis, 388 cases involved patellar denervation, and 388 cases were designated as the control group. The meta-analysis revealed no significant difference in the incidence of anterior knee pain (AKP, p = 0.18) or in the visual analogue scale score (VAS, p = 0.23) between the two groups. In addition, AKSS Function Score indicated no significant difference between the two groups (p = 0.28). However, the OKS (p = 0.02), patellar score (p = 0.01), AKSS-Knee Score (p = 0.004), range of motion (ROM, p < 0.0001) and WOMAC Score (p = 0.0003) indicated that circumpatellarelectrocautery improved clinical outcomes compared with non-electrocautery. The results indicate that circumferential electrocautery of the patella does not significantly improve AKP compared with non-electrocautery techniques but that circumferential electrocautery significantly improves patients' knee function after surgery. Therefore, we believe that circumferential electrocautery is beneficial to the outcome of primary TKR surgery without patellar replacement. PMID:25801456
Fan, Lihong; Ge, Zhaogang; Zhang, Chen; Li, Jia; Yu, Zefeng; Dang, Xiaoqian; Wang, Kunzheng
2015-03-24
The purpose of this meta-analysis and systematic review was to identify and assess whether circumferential electrocautery is useful for improving outcomes after primary total knee replacement(TKR). We searched MEDLINE, EMBASE, PubMed, SpringerLink, Web of Knowledge, OVID CINAHL, OVID EBM and Google Scholar and included articles published through January 2014. A total of 6 articles met the inclusion criteria. Of the 776 cases included in the analysis, 388 cases involved patellar denervation, and 388 cases were designated as the control group. The meta-analysis revealed no significant difference in the incidence of anterior knee pain (AKP, p = 0.18) or in the visual analogue scale score (VAS, p = 0.23) between the two groups. In addition, AKSS Function Score indicated no significant difference between the two groups (p = 0.28). However, the OKS (p = 0.02), patellar score (p = 0.01), AKSS-Knee Score (p = 0.004), range of motion (ROM, p < 0.0001) and WOMAC Score (p = 0.0003) indicated that circumpatellarelectrocautery improved clinical outcomes compared with non-electrocautery. The results indicate that circumferential electrocautery of the patella does not significantly improve AKP compared with non-electrocautery techniques but that circumferential electrocautery significantly improves patients' knee function after surgery. Therefore, we believe that circumferential electrocautery is beneficial to the outcome of primary TKR surgery without patellar replacement.
NASA Astrophysics Data System (ADS)
Fan, Lihong; Ge, Zhaogang; Zhang, Chen; Li, Jia; Yu, Zefeng; Dang, Xiaoqian; Wang, Kunzheng
2015-03-01
The purpose of this meta-analysis and systematic review was to identify and assess whether circumferential electrocautery is useful for improving outcomes after primary total knee replacement(TKR). We searched MEDLINE, EMBASE, PubMed, SpringerLink, Web of Knowledge, OVID CINAHL, OVID EBM and Google Scholar and included articles published through January 2014. A total of 6 articles met the inclusion criteria. Of the 776 cases included in the analysis, 388 cases involved patellar denervation, and 388 cases were designated as the control group. The meta-analysis revealed no significant difference in the incidence of anterior knee pain (AKP, p = 0.18) or in the visual analogue scale score (VAS, p = 0.23) between the two groups. In addition, AKSS Function Score indicated no significant difference between the two groups (p = 0.28). However, the OKS (p = 0.02), patellar score (p = 0.01), AKSS-Knee Score (p = 0.004), range of motion (ROM, p < 0.0001) and WOMAC Score (p = 0.0003) indicated that circumpatellarelectrocautery improved clinical outcomes compared with non-electrocautery. The results indicate that circumferential electrocautery of the patella does not significantly improve AKP compared with non-electrocautery techniques but that circumferential electrocautery significantly improves patients' knee function after surgery. Therefore, we believe that circumferential electrocautery is beneficial to the outcome of primary TKR surgery without patellar replacement.
Soegaard, Rikke; Bünger, Cody E; Christiansen, Terkel; Høy, Kristian; Eiskjaer, Søren P; Christensen, Finn B
2007-10-15
Cost-utility evaluation of a randomized, controlled trial with a 4- to 8-year follow-up. To investigate the incremental cost per quality-adjusted-life-year (QALY) when comparing circumferential fusion to posterolateral fusion in a long-term, societal perspective. The cost-effectiveness of circumferential fusion in a long-term perspective is uncertain but nonetheless highly relevant as the ISSLS prize winner 2006 in clinical studies reported the effect of circumferential fusion superior to the effect of posterolateral fusion. A recent trial found no significant difference between posterolateral and circumferential fusion reporting cost-effectiveness from a 2-year viewpoint. A total of 146 patients were randomized to posterolateral or circumferential fusion and followed 4 to 8 years after surgery. The mean age of the cohort was 46 years (range, 20-65 years); 61% were females, 49% were smokers, 30% had primary diagnosis of isthmic spondylolisthesis, 35% had disc degeneration and no previous surgery, and 35% had disc degeneration and previous surgery. Eighty-two percent of patients have had symptoms for more than 2 years and 50% were out of the labor market due to sickness. The EQ-5D instrument was applied for the measurement of health-related quality of life and costs (2004 U.S. dollars) were measured in a full-scale societal perspective. Productivity costs were valued by the Friction Cost method, and both costs and effects were discounted. Arithmetic means and 95% bias-corrected, bootstrapped confidence intervals were reported. Nonparametric statistics were used for tests of statistical significance. Comprehensive sensitivity analysis was conducted and reported using cost-effectiveness acceptability curves. The circumferential group demonstrated clinical superiority over the posterolateral fusion group in functional outcome (P < 0.01), fusion rate (P < 0.04), and number of reoperations (P < 0.01) among others. Cost-utility analysis demonstrated circumferential fusion
Rodrigues, Jonathan C.L.; Amadu, Antonio Matteo; Ghosh Dastidar, Amardeep; McIntyre, Bethannie; Szantho, Gergley V.; Lyen, Stephen; Godsave, Cattleya; Ratcliffe, Laura E.K.; Burchell, Amy E.; Hart, Emma C.; Hamilton, Mark C.K.; Nightingale, Angus K.; Paton, Julian F.R.; Manghat, Nathan E.; Bucciarelli-Ducci, Chiara
2017-01-01
Aims In hypertension, the presence of left ventricular (LV) strain pattern on 12-lead electrocardiogram (ECG) carries adverse cardiovascular prognosis. The underlying mechanisms are poorly understood. We investigated whether hypertensive ECG strain is associated with myocardial interstitial fibrosis and impaired myocardial strain, assessed by multi-parametric cardiac magnetic resonance (CMR). Methods and results A total of 100 hypertensive patients [50 ± 14 years, male: 58%, office systolic blood pressure (SBP): 170 ± 30 mmHg, office diastolic blood pressure (DBP): 97 ± 14 mmHg) underwent ECG and 1.5T CMR and were compared with 25 normotensive controls (46 ± 14 years, 60% male, SBP: 124 ± 8 mmHg, DBP: 76 ± 7 mmHg). Native T1 and extracellular volume fraction (ECV) were calculated with the modified look-locker inversion-recovery sequence. Myocardial strain values were estimated with voxel-tracking software. ECG strain (n = 20) was associated with significantly higher indexed LV mass (LVM) (119 ± 32 vs. 80 ± 17 g/m2, P < 0.05) and ECV (30 ± 4 vs. 27 ± 3%, P < 0.05) compared with hypertensive subjects without ECG strain (n = 80). ECG strain subjects had significantly impaired circumferential strain compared with hypertensive subjects without ECG strain and controls (−15.2 ± 4.7 vs. −17.0 ± 3.3 vs. −17.3 ± 2.4%, P < 0.05, respectively). In subgroup analysis, comparing ECG strain subjects to hypertensive subjects with elevated LVM but no ECG strain, a significantly higher ECV (30 ± 4 vs. 28 ± 3%, P < 0.05) was still observed. Indexed LVM was the only variable independently associated with ECG strain in multivariate logistic regression analysis [odds ratio (95th confidence interval): 1.07 (1.02–1.12), P < 0.05). Conclusion In hypertension, ECG strain is a marker of advanced LVH associated with increased interstitial fibrosis and associated with significant myocardial circumferential strain impairment. PMID:27334442
Rodrigues, Jonathan C L; Amadu, Antonio Matteo; Ghosh Dastidar, Amardeep; McIntyre, Bethannie; Szantho, Gergley V; Lyen, Stephen; Godsave, Cattleya; Ratcliffe, Laura E K; Burchell, Amy E; Hart, Emma C; Hamilton, Mark C K; Nightingale, Angus K; Paton, Julian F R; Manghat, Nathan E; Bucciarelli-Ducci, Chiara
2017-04-01
In hypertension, the presence of left ventricular (LV) strain pattern on 12-lead electrocardiogram (ECG) carries adverse cardiovascular prognosis. The underlying mechanisms are poorly understood. We investigated whether hypertensive ECG strain is associated with myocardial interstitial fibrosis and impaired myocardial strain, assessed by multi-parametric cardiac magnetic resonance (CMR). A total of 100 hypertensive patients [50 ± 14 years, male: 58%, office systolic blood pressure (SBP): 170 ± 30 mmHg, office diastolic blood pressure (DBP): 97 ± 14 mmHg) underwent ECG and 1.5T CMR and were compared with 25 normotensive controls (46 ± 14 years, 60% male, SBP: 124 ± 8 mmHg, DBP: 76 ± 7 mmHg). Native T1 and extracellular volume fraction (ECV) were calculated with the modified look-locker inversion-recovery sequence. Myocardial strain values were estimated with voxel-tracking software. ECG strain (n = 20) was associated with significantly higher indexed LV mass (LVM) (119 ± 32 vs. 80 ± 17 g/m2, P < 0.05) and ECV (30 ± 4 vs. 27 ± 3%, P < 0.05) compared with hypertensive subjects without ECG strain (n = 80). ECG strain subjects had significantly impaired circumferential strain compared with hypertensive subjects without ECG strain and controls (-15.2 ± 4.7 vs. -17.0 ± 3.3 vs. -17.3 ± 2.4%, P < 0.05, respectively). In subgroup analysis, comparing ECG strain subjects to hypertensive subjects with elevated LVM but no ECG strain, a significantly higher ECV (30 ± 4 vs. 28 ± 3%, P < 0.05) was still observed. Indexed LVM was the only variable independently associated with ECG strain in multivariate logistic regression analysis [odds ratio (95th confidence interval): 1.07 (1.02-1.12), P < 0.05). In hypertension, ECG strain is a marker of advanced LVH associated with increased interstitial fibrosis and associated with significant myocardial circumferential strain impairment. © The Author 2016. Published by Oxford University Press on behalf of the European Society
NASA Astrophysics Data System (ADS)
Huang, Alex S.; Belghith, Akram; Dastiridou, Anna; Chopra, Vikas; Zangwill, Linda M.; Weinreb, Robert N.
2017-06-01
The purpose was to create a three-dimensional (3-D) model of circumferential aqueous humor outflow (AHO) in a living human eye with an automated detection algorithm for Schlemm's canal (SC) and first-order collector channels (CC) applied to spectral-domain optical coherence tomography (SD-OCT). Anterior segment SD-OCT scans from a subject were acquired circumferentially around the limbus. A Bayesian Ridge method was used to approximate the location of the SC on infrared confocal laser scanning ophthalmoscopic images with a cross multiplication tool developed to initiate SC/CC detection automated through a fuzzy hidden Markov Chain approach. Automatic segmentation of SC and initial CC's was manually confirmed by two masked graders. Outflow pathways detected by the segmentation algorithm were reconstructed into a 3-D representation of AHO. Overall, only <1% of images (5114 total B-scans) were ungradable. Automatic segmentation algorithm performed well with SC detection 98.3% of the time and <0.1% false positive detection compared to expert grader consensus. CC was detected 84.2% of the time with 1.4% false positive detection. 3-D representation of AHO pathways demonstrated variably thicker and thinner SC with some clear CC roots. Circumferential (360 deg), automated, and validated AHO detection of angle structures in the living human eye with reconstruction was possible.
Wang, Bin; Shao, Yanchun; Chen, Tao; Chen, Wanping; Chen, Fusheng
2015-01-01
Acetobacter pasteurianus (Ap) CICC 20001 and CGMCC 1.41 are two acetic acid bacteria strains that, because of their strong abilities to produce and tolerate high concentrations of acetic acid, have been widely used to brew vinegar in China. To globally understand the fermentation characteristics, acid-tolerant mechanisms and genetic stabilities, their genomes were sequenced. Genomic comparisons with 9 other sequenced Ap strains revealed that their chromosomes were evolutionarily conserved, whereas the plasmids were unique compared with other Ap strains. Analysis of the acid-tolerant metabolic pathway at the genomic level indicated that the metabolism of some amino acids and the known mechanisms of acetic acid tolerance, might collaboratively contribute to acetic acid resistance in Ap strains. The balance of instability factors and stability factors in the genomes of Ap CICC 20001 and CGMCC 1.41 strains might be the basis for their genetic stability, consistent with their stable industrial performances. These observations provide important insights into the acid resistance mechanism and the genetic stability of Ap strains and lay a foundation for future genetic manipulation and engineering of these two strains. PMID:26691589
Perioperative Assessment of Myocardial Deformation
Duncan, Andra E.; Alfirevic, Andrej; Sessler, Daniel I.; Popovic, Zoran B.; Thomas, James D.
2014-01-01
Evaluation of left ventricular performance improves risk assessment and guides anesthetic decisions. However, the most common echocardiographic measure of myocardial function, the left ventricular ejection fraction (LVEF), has important limitations. LVEF is limited by subjective interpretation which reduces accuracy and reproducibility, and LVEF assesses global function without characterizing regional myocardial abnormalities. An alternative objective echocardiographic measure of myocardial function is thus needed. Myocardial deformation analysis, which performs quantitative assessment of global and regional myocardial function, may be useful for perioperative care of surgical patients. Myocardial deformation analysis evaluates left ventricular mechanics by quantifying strain and strain rate. Strain describes percent change in myocardial length in the longitudinal (from base to apex) and circumferential (encircling the short-axis of the ventricle) direction and change in thickness in the radial direction. Segmental strain describes regional myocardial function. Strain is a negative number when the ventricle shortens longitudinally or circumferentially and is positive with radial thickening. Reference values for normal longitudinal strain from a recent meta-analysis using transthoracic echocardiography are (mean ± SD) −19.7 ± 0.4%, while radial and circumferential strain are 47.3 ± 1.9 and −23.3 ± 0.7%, respectively. The speed of myocardial deformation is also important and is characterized by strain rate. Longitudinal systolic strain rate in healthy subjects averages −1.10 ± 0.16 sec−1. Assessment of myocardial deformation requires consideration of both strain (change in deformation), which correlates with LVEF, and strain rate (speed of deformation), which correlates with rate of rise of left ventricular pressure (dP/dt). Myocardial deformation analysis also evaluates ventricular relaxation, twist, and untwist, providing new and noninvasive methods to
Airway and Parenchymal Strains during Bronchoconstriction in the Precision Cut Lung Slice
Hiorns, Jonathan E.; Bidan, Cécile M.; Jensen, Oliver E.; Gosens, Reinoud; Kistemaker, Loes E. M.; Fredberg, Jeffrey J.; Butler, Jim P.; Krishnan, Ramaswamy; Brook, Bindi S.
2016-01-01
The precision-cut lung slice (PCLS) is a powerful tool for studying airway reactivity, but biomechanical measurements to date have largely focused on changes in airway caliber. Here we describe an image processing tool that reveals the associated spatio-temporal changes in airway and parenchymal strains. Displacements of sub-regions within the PCLS are tracked in phase-contrast movies acquired after addition of contractile and relaxing drugs. From displacement maps, strains are determined across the entire PCLS or along user-specified directions. In a representative mouse PCLS challenged with 10−4M methacholine, as lumen area decreased, compressive circumferential strains were highest in the 50 μm closest to the airway lumen while expansive radial strains were highest in the region 50–100 μm from the lumen. However, at any given distance from the airway the strain distribution varied substantially in the vicinity of neighboring small airways and blood vessels. Upon challenge with the relaxant agonist chloroquine, although most strains disappeared, residual positive strains remained a long time after addition of chloroquine, predominantly in the radial direction. Taken together, these findings establish strain mapping as a new tool to elucidate local dynamic mechanical events within the constricting airway and its supporting parenchyma. PMID:27559314
Spalla, I; Locatelli, C; Zanaboni, A M; Brambilla, P; Bussadori, C
2016-05-01
Patent ductus arteriosus (PDA) is one of the most common congenital heart defects in dogs. Advanced echocardiographic techniques such as speckle-tracking echocardiography (STE) have not been extensively used to evaluate cardiac function in affected dogs. Advanced echocardiographic techniques are more sensitive than standard echocardiographic techniques in analyzing systolic function in dogs with PDA. Forty-four client-owned dogs: 34 dogs with PDA (preoperative evaluation) and 10 healthy sex- and weight-matched controls. Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed, including conventional (end-diastolic volumes indexed to body surface area in B and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B and M-mode [ESVIB /M ], allometric scaling in diastole and systole [AlloD/S], pulmonary flow to systemic flow [Qp/Qs], ejection fraction [EF] and fractional shortening [FS]) and speckle-tracking echocardiography ([STE]: global longitudinal, radial and circumferential strain [S] and strain rate [SR]). Dogs with PDA had significantly different EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs and all STE-derived parameters (global longitudinal S and SR, global circumferential S and SR, global radial S and SR)compared to healthy dogs. No correlation was found between standard techniques (EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs) and STE-derived parameters (global longitudinal, circumferential and radial S and SR). Conventional parameters routinely used to assess systolic function (EF and FS) were not different between the groups; STE-derived parameters identified subtle changes in cardiac systolic function and contractility between the 2 groups of dogs. Based on these findings, STE may be a more appropriate tool to assess cardiac contractility in dogs with PDA. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College
Recent evaluations of crack-opening-area in circumferentially cracked pipes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, S.; Brust, F.; Ghadiali, N.
1997-04-01
Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. The leak rates depend on the crack-opening area of the through-wall crack in the pipe. In addition to LBB analyses which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessingmore » temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section XI. The objectives of this study were to review, evaluate, and refine current predictive models for performing crack-opening-area analyses of circumferentially cracked pipes. The results from twenty-five full-scale pipe fracture experiments, conducted in the Degraded Piping Program, the International Piping Integrity Research Group Program, and the Short Cracks in Piping and Piping Welds Program, were used to verify the analytical models. Standard statistical analyses were performed to assess used to verify the analytical models. Standard statistical analyses were performed to assess quantitatively the accuracy of the predictive models. The evaluation also involved finite element analyses for determining the crack-opening profile often needed to perform leak-rate calculations.« less
NASA Astrophysics Data System (ADS)
Sebold, Jean Eduardo; de Lacerda, Luiz Alkimin
2018-04-01
This paper describes a substantiated mathematical theory for Rayleigh waves propagated on some types of metal cylinders. More specifically, it presents not only a new way to express the dispersion relation of Rayleigh waves propagated on the cylindrical surface, but also how it can be used to construct a mathematical equation showing that the applied static mechanical pressure affects the shear modulus of the metal cylinder. All steps, required to conclude the process, consider the equation of motion as a function of radial and circumferential coordinates only, while the axial component can be overlooked without causing any problems. Some numerical experiments are done to illustrate the changes in the Rayleigh circumferential phase velocity in a metal cylindrical section due to static mechanical pressure around its external surface.
NASA Astrophysics Data System (ADS)
Jezequel, T.; Auzoux, Q.; Le Boulch, D.; Bono, M.; Andrieu, E.; Blanc, C.; Chabretou, V.; Mozzani, N.; Rautenberg, M.
2018-02-01
During accidental power transient conditions with Pellet Cladding Interaction (PCI), the synergistic effect of the stress and strain imposed on the cladding by thermal expansion of the fuel, and corrosion by iodine released as a fission product, may lead to cladding failure by Stress Corrosion Cracking (SCC). In this study, internal pressure tests were conducted on unirradiated cold-worked stress-relieved Zircaloy-4 cladding tubes in an iodine vapor environment. The goal was to investigate the influence of loading type (constant pressure tests, constant circumferential strain rate tests, or constant circumferential strain tests) and test temperature (320, 350, or 380 °C) on iodine-induced stress corrosion cracking (I-SCC). The experimental results obtained with different loading types were consistent with each other. The apparent threshold hoop stress for I-SCC was found to be independent of the test temperature. SEM micrographs of the tested samples showed many pits distributed over the inner surface, which tended to coalesce into large pits in which a microcrack could initiate. A model for the time-to-failure of a cladding tube was developed using finite element simulations of the viscoplastic mechanical behavior of the material and a modified Kachanov's damage growth model. The times-to-failure predicted by this model are consistent with the experimental data.
NASA Astrophysics Data System (ADS)
Chen, X.; Qin, G.; Ai, Z.; Ji, Y.
2017-08-01
As an effective and economic method for flow range enhancement, circumferential groove casing treatment (CGCT) is widely used to increase the stall margin of compressors. Different from traditional grooved casing treatments, in which the grooves are always located over the rotor in both axial and radial compressors, one or several circumferential grooves are located along the shroud side of the diffuser passage in this paper. Numerical investigations were conducted to predict the performance of a low flow rate centrifugal compressor with CGCT in diffuser. Computational fluid dynamics (CFD) analysis is performed under stage environment in order to find the optimum location of the circumferential casing groove in consideration of stall margin enhancement and efficiency gain at design point, and the impact of groove number to the effect of this grooved casing treatment configuration in enhancing the stall margin of the compressor stage is studied. The results indicate that the centrifugal compressor with circumferential groove in vaned diffuser can obtain obvious improvement in the stall margin with sacrificing design efficiency a little. Efforts were made to study blade level flow mechanisms to determine how the CGCT impacts the compressor’s stall margin (SM) and performance. The flow structures in the passage, the tip gap, and the grooves as well as their mutual interactions were plotted and analysed.
The effect of circumferential distortion on fan performance at two levels of blade loading
NASA Technical Reports Server (NTRS)
Hartmann, M. J.; Sanger, N. L.
1975-01-01
Single stage fans designed for two levels of pressure ratio or blade loading were subjected to screen-induced circumferential distortions of 90-degree extent. Both fan rotors were designed for a blade tip speed of 425 m/sec, blade solidity of 1.3 and a hub-to-tip radius ratio of 0.5. Circumferential measurements of total pressure, temperature, static pressure, and flow angle were obtained at the hub, mean and tip radii at five axial stations. Rotor loading level did not appear to have a significant influence on rotor response to distorted flow. Losses in overall pressure ratio due to distortion were most severe in the stator hub region of the more highly loaded stage. At the near stall operating condition tip and hub regions of (either) rotor demonstrated different response characteristics to the distorted flow. No effect of loading was apparent on interactions between rotor and upstream distorted flow fields.
Huang, Alex S; Belghith, Akram; Dastiridou, Anna; Chopra, Vikas; Zangwill, Linda M; Weinreb, Robert N
2017-06-01
The purpose was to create a three-dimensional (3-D) model of circumferential aqueous humor outflow (AHO) in a living human eye with an automated detection algorithm for Schlemm’s canal (SC) and first-order collector channels (CC) applied to spectral-domain optical coherence tomography (SD-OCT). Anterior segment SD-OCT scans from a subject were acquired circumferentially around the limbus. A Bayesian Ridge method was used to approximate the location of the SC on infrared confocal laser scanning ophthalmoscopic images with a cross multiplication tool developed to initiate SC/CC detection automated through a fuzzy hidden Markov Chain approach. Automatic segmentation of SC and initial CC’s was manually confirmed by two masked graders. Outflow pathways detected by the segmentation algorithm were reconstructed into a 3-D representation of AHO. Overall, only <1% of images (5114 total B-scans) were ungradable. Automatic segmentation algorithm performed well with SC detection 98.3% of the time and <0.1% false positive detection compared to expert grader consensus. CC was detected 84.2% of the time with 1.4% false positive detection. 3-D representation of AHO pathways demonstrated variably thicker and thinner SC with some clear CC roots. Circumferential (360 deg), automated, and validated AHO detection of angle structures in the living human eye with reconstruction was possible.
Koene, S; Timmermans, J; Weijers, G; de Laat, P; de Korte, C L; Smeitink, J A M; Janssen, M C H; Kapusta, L
2017-03-01
Cardiomyopathy is a common complication of mitochondrial disorders, associated with increased mortality. Two dimensional speckle tracking echocardiography (2DSTE) can be used to quantify myocardial deformation. Here, we aimed to determine the usefulness of 2DSTE in detecting and monitoring subtle changes in myocardial dysfunction in carriers of the 3243A>G mutation in mitochondrial DNA. In this retrospective pilot study, 30 symptomatic and asymptomatic carriers of the mitochondrial 3243A>G mutation of whom two subsequent echocardiograms were available were included. We measured longitudinal, circumferential and radial strain using 2DSTE. Results were compared to published reference values. Speckle tracking was feasible in 90 % of the patients for longitudinal strain. Circumferential and radial strain showed low face validity (low number of images with sufficient quality; suboptimal tracking) and were therefore rejected for further analysis. Global longitudinal strain showed good face validity, and was abnormal in 56-70 % (depending on reference values used) of the carriers (n = 27). Reproducibility was good (mean difference of 0.83 for inter- and 0.40 for intra-rater reproducibility; ICC 0.78 and 0.89, respectively). The difference between the first and the second measurement exceeded the measurement variance in 39 % of the cases (n = 23; feasibility of follow-up 77 %). Even in data collected as part of clinical care, two-dimensional strain echocardiography seems a feasible method to detect and monitor subtle changes in longitudinal myocardial deformation in adult carriers of the mitochondrial 3243A>G mutation. Based on our data and the reported accuracy of global longitudinal strain in other studies, we suggest the use of global longitudinal strain in a prospective follow-up or intervention study.
Zhong, Jia; Yu, Xin
2010-01-01
In the current study, a 2D multi-phase MR displacement encoding with stimulated echoes (DENSE) imaging and analysis method was developed for direct quantification of Lagrangian strain in the mouse heart. Using the proposed method, less than 10 ms temporal resolution and 0.56 mm in-plane resolution were achieved. A validation study that compared strain calculation by DENSE and by MR tagging showed high correlation between the two methods (R2 > 0.80). Regional ventricular wall strain and twist were characterized in mouse hearts at baseline and under dobutamine stimulation. Dobutamine stimulation induced significant increase in radial and circumferential strains and torsion at peak-systole. A rapid untwisting was also observed during early diastole. This work demonstrates the capability of characterizing cardiac functional response to dobutamine stimulation in the mouse heart using 2D multi-phase MR DENSE. PMID:20740659
Garner, Ethan C; Bernard, Remi; Wang, Wenqin; Zhuang, Xiaowei; Rudner, David Z; Mitchison, Tim
2011-07-08
Rod-shaped bacteria elongate by the action of cell wall synthesis complexes linked to underlying dynamic MreB filaments. To understand how the movements of these filaments relate to cell wall synthesis, we characterized the dynamics of MreB and the cell wall elongation machinery using high-precision particle tracking in Bacillus subtilis. We found that MreB and the elongation machinery moved circumferentially around the cell, perpendicular to its length, with nearby synthesis complexes and MreB filaments moving independently in both directions. Inhibition of cell wall synthesis by various methods blocked the movement of MreB. Thus, bacteria elongate by the uncoordinated, circumferential movements of synthetic complexes that insert radial hoops of new peptidoglycan during their transit, possibly driving the motion of the underlying MreB filaments.
Badano, Luigi P; Cucchini, Umberto; Muraru, Denisa; Al Nono, Osama; Sarais, Cristiano; Iliceto, Sabino
2013-03-01
Since there is insufficient data available about the inter-vendor consistency of three-dimensional (3D) speckle-tracking (STE) measurements, we undertook this study to (i) assess the inter-vendor consistency of 3D LV global strain values obtained using two different scanners; (ii) identify the sources of inter-vendor inconsistencies, if any; and (iii) compare their respective intrinsic variability. Sixty patients (38 ± 12 years, 64% males) with a wide range of LV end-diastolic volumes (from 74 to 205 ml) and ejection fractions (from 17 to 70%) underwent two 3D LV data set acquisitions using VividE9 and Artida ultrasound systems. Global longitudinal (Lε), radial (Rε), circumferential (Cε) and area (Aε) strain values were obtained offline using the corresponding 3D STE softwares. Despite being significantly different, Lε showed the closest values between the two platforms (bias = 1.5%, limits of agreement (LOA) from -2.9 to -5.9%, P < 0.05). Artida produced significantly higher values of both Cε and Aε than VividE9 (bias = 6.6, LOA: -14.1 to 0.9%, and bias = 6.0, LOA = -28.2-8.6%, respectively, P < 0.001). Conversely, Rε values obtained with Artida were significantly lower than those measured using VividE9 platform (bias = -24.2, LOA: 1.5-49.9, P < 0.001). All strain components showed good reproducibility (intra-class correlation coefficients: 0.82-0.98), except for Rε by Artida, which showed only a moderate reproducibility. Apart from Lε, the inter-vendor agreement of Rε, Cε and Aε measured with Artida and VividE9 was poor. Reference values should be specific for each system and baseline and follow-up data in longitudinal studies should be obtained using the same 3D STE platform.
Measurements of the Exerted Pressure by Pelvic Circumferential Compression Devices
Knops, Simon P; van Riel, Marcel P.J.M; Goossens, Richard H.M; van Lieshout, Esther M.M; Patka, Peter; Schipper, Inger B
2010-01-01
Background: Data on the efficacy and safety of non-invasive Pelvic Circumferential Compression Devices (PCCDs) is limited. Tissue damage may occur if a continuous pressure on the skin exceeding 9.3 kPa is sustained for more than two or three hours. The aim of this study was to gain insight into the pressure build-up at the interface, by measuring the PCCD-induced pressure when applying pulling forces to three different PCCDs (Pelvic Binder® , SAM-Sling ® and T-POD® ) in a simplified model. Methods: The resulting exerted pressures were measured at four ‘anatomical’ locations (right, left, posterior and anterior) in a model using a pressure measurement system consisting of pressure cuffs. Results: The exerted pressure varied substantially between the locations as well as between the PCCDs. Maximum pressures ranged from 18.9-23.3 kPa and from 19.2-27.5 kPa at the right location and left location, respectively. Pressures at the posterior location stayed below 18 kPa. At the anterior location pressures varied markedly between the different PCCDs. Conclusion: The circumferential compression by the different PCCDs showed high pressures measured at the four locations using a simplified model. Difference in design and functional characteristics of the PCCDs resulted in different pressure build-up at the four locations. When following the manufacturer’s instructions, the exerted pressure of all three PCCDs tested exceeded the tissue damaging level (9.3 kPa). In case of prolonged use in a clinical situation this might put patients at risk for developing tissue damage. PMID:20361001
Kuribayashi, Yasutaka; Iizuka, Toshiro; Nomura, Kosuke; Furuhata, Tsukasa; Yamashita, Satoshi; Matsui, Akira; Kikuchi, Daisuke; Mitani, Toshifumi; Kaise, Mitsuru; Hoteya, Shu
2018-06-05
Endoscopic submucosal dissection (ESD) for superficial esophageal cancer is sometimes extensive, and in our experience, patients not infrequently present with dysphagia after ESD even in the absence of esophageal stricture. The aim of this study was to evaluate esophageal motility using high-resolution manometry (HRM) in patients with and without dysphagia after extensive circumferential ESD. HRM was performed in a total of 52 patients who had undergone ESD for superficial esophageal cancer and a mucosal defect after ESD exceeded more than two-thirds of the esophageal circumference. The frequency and type of esophageal dysmotility and the relationship between esophageal motility and dysphagia were evaluated. Esophageal dysmotility was observed in 13 patients (25%): jackhammer esophagus in 4, esophagogastric junction outflow obstruction in 4, absent contractility in 2, and distal esophageal spasm, ineffective esophageal motility, and fragmented peristalsis in 1 patient each. Of the 22 patients with dysphagia after ESD, 9 (41%) had esophageal dysmotility. Of the 30 patients without dysphagia after ESD, 4 (13%) had esophageal dysmotility. The relationship between dysmotility and dysphagia was significant (p = 0.025). Esophageal dysmotility exists in approximately one-quarter of patients after extensive circumferential ESD, which is associated with dysphagia in the absence of esophageal stricture. © 2018 S. Karger AG, Basel.
Fetal myocardial deformation in maternal diabetes mellitus and obesity.
Kulkarni, A; Li, L; Craft, M; Nanda, M; Lorenzo, J M M; Danford, D; Kutty, S
2017-05-01
Experimental evidence suggests that changes in the fetal myocardium result from intrauterine effects of maternal diabetes mellitus and obesity. The aim of this study was to assess fetal cardiac function using two-dimensional speckle-tracking echocardiography to determine the effects of maternal diabetes and obesity on the fetal myocardium. Comparative cross-sectional evaluation of myocardial function in fetuses of mothers with diabetes mellitus (FDM) or obesity (FO) and normal gestational age-matched control fetuses (FC) was performed using two-dimensional speckle-tracking echocardiography at two centers. In total, 178 fetuses (82 FDM, 26 FO and 70 FC) met the enrolment criteria. Mean gestational age at assessment was similar among groups: 25.3 ± 5.1 weeks for FDM, 25.0 ± 4.6 weeks for FO and 25.1 ± 4.9 weeks for FC. Mean maternal body mass index was significantly higher in FDM and FO groups compared with the FC group. Statistically significant differences in fetal cardiac function were detected between FDM and FC for global longitudinal strain (mean ± SD, -21.4 ± 6.5% vs -27.0 ± 5.2%; P < 0.001), global circumferential strain (mean ± SD, -22.6 ± 6.5% vs -26.2 ± 6.8%; P = 0.002), average longitudinal systolic strain rate (median, -1.4 (interquartile range (IQR), -1.7 to -1.1)/s vs -1.6 (IQR, -2.0 to -1.4)/s; P = 0.001) and average circumferential systolic strain rate (median, -1.4 (IQR, -1.9 to -1.1)/s vs -1.6 (IQR, -2.1 to -1.3)/s; P = 0.006). Cases of non-obese FDM also had abnormal strain parameters compared with FC. Global longitudinal strain (mean ± SD, -21.1 ± 7.5%) and average circumferential systolic strain rate (median, -1.3 (IQR, -1.8 to -1.1)/s) were significantly lower in FO compared with FC. Unfavorable changes occur in the fetal myocardium in response to both maternal diabetes mellitus and obesity. The long-term prognostic implications of these changes require further study
Burkett, Dale A; Slorach, Cameron; Patel, Sonali S; Redington, Andrew N; Ivy, D Dunbar; Mertens, Luc; Younoszai, Adel K; Friedberg, Mark K
2015-08-01
Through ventricular interdependence, pulmonary hypertension (PH) induces left ventricular (LV) dysfunction. We hypothesized that LV strain/strain rate, surrogate measures of myocardial contractility, are reduced in pediatric PH and relate to invasive hemodynamics, right ventricular strain, and functional measures of PH. At 2 institutions, echocardiography was prospectively performed in 54 pediatric PH patients during cardiac catheterization, and in 54 matched controls. Patients with PH had reduced LV global longitudinal strain (LS; -18.8 [-17.3 to -20.4]% versus -20.2 [-19.0 to -20.9]%; P=0.0046) predominantly because of reduced basal (-12.9 [-10.8 to -16.3]% versus -17.9 [-14.5 to -20.7]%; P<0.0001) and mid (-17.5 [-15.5 to -19.0]% versus -21.1 [-19.1 to -23.0]%; P<0.0001) septal strain. Basal global circumferential strain was reduced (-18.7 [-15.7 to -22.1]% versus -20.6 [-19.0 to -22.5]%; P=0.0098), as were septal and free-wall segments. Mid circumferential strain was reduced within the free-wall. Strain rates were reduced in similar patterns. Basal septum LS, the combined average LS of basal and mid interventricular septal segments, correlated strongly with degree of PH (r=0.66; P<0.0001), pulmonary vascular resistance (r=0.60; P<0.0001), and right ventricular free-wall LS (r=0.64; P<0.0001). Brain natriuretic peptide levels correlated moderately with septal LS (r=0.48; P=0.0038). PH functional class correlated moderately with LV free-wall LS (r=-0.48; P=0.0051). The septum, shared between ventricles and affected by septal shift, was the most affected LV region in PH. Pediatric PH patients demonstrate reduced LV strain/strain rate, predominantly within the septum, with relationships to invasive hemodynamics, right ventricular strain, and functional PH measures. © 2015 American Heart Association, Inc.
Meng, Leng; Lin, Kai; Collins, Jeremy; Markl, Michael; Carr, James C
2017-08-01
The purpose of this article is to test the hypothesis that heart deformation analysis can automatically quantify regional myocardial motion patterns in patients with cardiac amyloidosis. Eleven patients with cardiac amyloidosis and 11 healthy control subjects were recruited to undergo cardiac MRI. Cine images were analyzed using heart deformation analysis and feature tracking. Heart deformation analysis-derived myocardial motion indexes in radial and circumferential directions, including radial and circumferential displacement, radial and circumferential velocity, radial and circumferential strain, and radial and circumferential strain rate, were compared between the two groups. The heart deformation analysis tool required a shorter mean (± SD) processing time than did the feature-tracking tool (1.5 ± 0.3 vs 5.1 ± 1.2 minutes). Patients with cardiac amyloidosis had lower peak radial displacement (4.32 ± 1.37 vs 5.62 ± 1.19 mm), radial velocity (25.50 ± 7.70 vs 33.41 ± 5.43 mm/s), radial strain (23.32% ± 10.24% vs 31.21% ± 8.71%), circumferential strain (-13.44% ± 4.21% vs -17.84% ± 2.84%), radial strain rate (1.14 ± 0.46 vs 1.58 ± 0.41 s -1 ), and circumferential strain rate (-0.78 ± 0.22 vs -1.08 ± 0.20 s -1 ) than did healthy control subjects. Heart deformation analysis-derived indexes correlated with feature tracking-derived indexes (r = 0.411 and 0.552). Heart deformation analysis is able to automatically quantify regional myocardial motion in patients with cardiac amyloidosis without the need for operator interaction.
Le Hello, Simon; Bekhit, Amany; Granier, Sophie A; Barua, Himel; Beutlich, Janine; Zając, Magdalena; Münch, Sebastian; Sintchenko, Vitali; Bouchrif, Brahim; Fashae, Kayode; Pinsard, Jean-Louis; Sontag, Lucile; Fabre, Laetitia; Garnier, Martine; Guibert, Véronique; Howard, Peter; Hendriksen, Rene S; Christensen, Jens P; Biswas, Paritosh K; Cloeckaert, Axel; Rabsch, Wolfgang; Wasyl, Dariusz; Doublet, Benoit; Weill, François-Xavier
2013-01-01
While the spread of Salmonella enterica serotype Kentucky resistant to ciprofloxacin across Africa and the Middle-East has been described recently, the presence of this strain in humans, food, various animal species (livestock, pets, and wildlife) and in environment is suspected in other countries of different continents. Here, we report results of an in-depth molecular epidemiological study on a global human and non-human collection of S. Kentucky (n = 70). We performed XbaI-pulsed field gel electrophoresis and multilocus sequence typing, assessed mutations in the quinolone resistance-determining regions, detected β-lactam resistance mechanisms, and screened the presence of the Salmonella genomic island 1 (SGI1). In this study, we highlight the rapid and extensive worldwide dissemination of the ciprofloxacin-resistant S. Kentucky ST198-X1-SGI1 strain since the mid-2000s in an increasingly large number of contaminated sources, including the environment. This strain has accumulated an increasing number of chromosomal and plasmid resistance determinants and has been identified in the Indian subcontinent, Southeast Asia and Europe since 2010. The second substitution at position 87 in GyrA (replacing the amino acid Asp) appeared helpful for epidemiological studies to track the origin of contamination. This global study provides evidence leading to the conclusion that high-level resistance to ciprofloxacin in S. Kentucky is a simple microbiological trait that facilitates the identification of the epidemic clone of interest, ST198-X1-SGI1. Taking this into account is essential in order to detect and monitor it easily and to take rapid measures in livestock to ensure control of this infection.
Le Hello, Simon; Bekhit, Amany; Granier, Sophie A.; Barua, Himel; Beutlich, Janine; Zając, Magdalena; Münch, Sebastian; Sintchenko, Vitali; Bouchrif, Brahim; Fashae, Kayode; Pinsard, Jean-Louis; Sontag, Lucile; Fabre, Laetitia; Garnier, Martine; Guibert, Véronique; Howard, Peter; Hendriksen, Rene S.; Christensen, Jens P.; Biswas, Paritosh K.; Cloeckaert, Axel; Rabsch, Wolfgang; Wasyl, Dariusz; Doublet, Benoit; Weill, François-Xavier
2013-01-01
While the spread of Salmonella enterica serotype Kentucky resistant to ciprofloxacin across Africa and the Middle-East has been described recently, the presence of this strain in humans, food, various animal species (livestock, pets, and wildlife) and in environment is suspected in other countries of different continents. Here, we report results of an in-depth molecular epidemiological study on a global human and non-human collection of S. Kentucky (n = 70). We performed XbaI-pulsed field gel electrophoresis and multilocus sequence typing, assessed mutations in the quinolone resistance-determining regions, detected β-lactam resistance mechanisms, and screened the presence of the Salmonella genomic island 1 (SGI1). In this study, we highlight the rapid and extensive worldwide dissemination of the ciprofloxacin-resistant S. Kentucky ST198-X1-SGI1 strain since the mid-2000s in an increasingly large number of contaminated sources, including the environment. This strain has accumulated an increasing number of chromosomal and plasmid resistance determinants and has been identified in the Indian subcontinent, Southeast Asia and Europe since 2010. The second substitution at position 87 in GyrA (replacing the amino acid Asp) appeared helpful for epidemiological studies to track the origin of contamination. This global study provides evidence leading to the conclusion that high-level resistance to ciprofloxacin in S. Kentucky is a simple microbiological trait that facilitates the identification of the epidemic clone of interest, ST198-X1-SGI1. Taking this into account is essential in order to detect and monitor it easily and to take rapid measures in livestock to ensure control of this infection. PMID:24385975
46 CFR 52.05-45 - Circumferential joints in pipes, tubes and headers (modifies PW-41).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Circumferential joints in pipes, tubes and headers (modifies PW-41). 52.05-45 Section 52.05-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Boilers Fabricated by Welding § 52.05-45...
46 CFR 52.05-45 - Circumferential joints in pipes, tubes and headers (modifies PW-41).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Circumferential joints in pipes, tubes and headers (modifies PW-41). 52.05-45 Section 52.05-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Boilers Fabricated by Welding § 52.05-45...
46 CFR 52.05-45 - Circumferential joints in pipes, tubes and headers (modifies PW-41).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Circumferential joints in pipes, tubes and headers (modifies PW-41). 52.05-45 Section 52.05-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Boilers Fabricated by Welding § 52.05-45...
46 CFR 52.05-45 - Circumferential joints in pipes, tubes and headers (modifies PW-41).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Circumferential joints in pipes, tubes and headers (modifies PW-41). 52.05-45 Section 52.05-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Boilers Fabricated by Welding § 52.05-45...
46 CFR 52.05-45 - Circumferential joints in pipes, tubes and headers (modifies PW-41).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Circumferential joints in pipes, tubes and headers (modifies PW-41). 52.05-45 Section 52.05-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Boilers Fabricated by Welding § 52.05-45...
The elasticity problem for a thick-walled cylinder containing a circumferential crack
NASA Technical Reports Server (NTRS)
Nied, H. F.; Erdogan, F.
1983-01-01
The elasticity problem for a long hollow circular cylinder containing an axisymmetric circumferential crack subjected to general nonaxisymmetric external loads is considered. The problem is formulated in terms of a system of singular integral equations with the Fourier coefficients of the derivative of the crack surface displacement as density functions. The stress intensity factors and the crack opening displacement are calculated for a cylinder under uniform tension, bending by end couples, and self-equilibrating residual stresses.
The elasticity problem for a thick-walled cylinder containing a circumferential crack
NASA Technical Reports Server (NTRS)
Nied, H. F.; Erdogan, F.
1982-01-01
The elasticity problem for a long hollow circular cylinder containing an axisymmetric circumferential crack subjected to general nonaxisymmetric external loads is considered. The problem is formulated in terms of a system of singular integral equations with the Fourier coefficients of the derivative of the crack surface displacement as density functions. The stress intensity factors and the crack opening displacement are calculated for a cylinder under uniform tension, bending by end couples, and self-equilibrating residual stresses.
Baltag, Ioana; Watanabe, Kouichi; Miyakawa, Osamu
2005-06-01
The behavior of molten titanium in molds of complicated shape is still insufficiently understood; consequently, definite spruing criteria are not yet available for titanium RPD frameworks. This study investigated the influence of sprue design on porosity in pressure-cast titanium circumferential clasps. The patterns of 90 circumferential clasps were sprued with three directions (0, 30 and 60 degrees , as measured between the sprue and the symmetry plane of the clasp assembly) and three sprue diameters (1.5, 2.0 and 2.5mm). CPTi was cast in a one-chamber pressure casting machine. Pore number and size were assessed on radiographs of the castings. Statistical analysis was done by two-way analysis of variance (ANOVA), followed by Fisher's PLSD post hoc test. The porosity in lingual arms increased significantly with increase of sprue diameter and sprue angle, while the porosity in minor connectors had an inversely proportional distribution. Very low porosity, uninfluenced by sprue design, was found in buccal arms. In conclusion, internal porosity in titanium circumferential clasp arms can be minimized through sprue design: the 0 degrees sprue direction produced the least porosity, while for the 30 and 60 degrees directions, 1.5mm diameter sprues produced lower porosity than 2.0 and 2.5mm diameter sprues. In this study, the lowest porosity in titanium circumferential clasp arms was obtained with sprues attached perpendicularly to the minor connectors, regardless of sprue diameter. Conventional sprue directions produced significantly higher porosity in clasp lingual arms, the amount of porosity increasing with sprue diameter.
McGarvey, Jeremy R; Kondo, Norihiro; Witschey, Walter RT; Takebe, Manabu; Aoki, Chikashi; Burdick, Jason A.; Spinale, Francis G; Gorman, Joseph H; Pilla, James J; Gorman, Robert C
2014-01-01
Background There is continued need for therapies which reverse or abate the remodeling process following myocardial infarction (MI). In this study, we evaluate the longitudinal effects of calcium hydroxyapatite microsphere gel on regional strain, global ventricular function, and mitral regurgitation (MR) in a porcine MI model. Methods Twenty five Yorkshire swine were enrolled. Five were dedicated weight-matched controls. Twenty underwent posterolateral infarction by direct ligation of the circumflex artery and its branches. Infarcted animals were randomly divided into four groups: one week treatment, one week control, four week treatment, and four week control. Following infarction, animals received either twenty 150μl calcium hydroxyapatite gel or saline injections within the infarct. At their respective timepoints, echocardiograms, cardiac MRI, and tissue were collected for evaluation of MR, regional and global left ventricular function, wall thickness, and collagen content. Results Global and regional LV function were depressed in all infarcted subjects at one week compared to healthy controls. By four weeks post-infarction, global function had significantly improved in the calcium hydroxyapatite group compared to infarcted controls (EF 48.5±1.9% vs. 38.0±1.7%, p<0.01). Similarly, regional borderzone radial contractile strain (16.3±1.5% vs. 11.2±1.5%, p=0.04), MR grade (0.4±0.2 vs. 1.2±0.2, p=0.04), and infarct thickness (7.8±0.5mm vs. 4.5±0.2mm, p<0.01) were improved at this timepoint in the treatment group compared to infarct controls. Conclusions Calcium hydroxyapatite injection following MI progressively improves global LV function, borderzone function, and mitral regurgitation. Using novel biomaterials to augment infarct material properties is viable alternative in the current management of heart failure. PMID:25524397
Transverse shear effect in a circumferentially cracked cylindrical shell
NASA Technical Reports Server (NTRS)
Delale, F.; Erdogan, F.
1979-01-01
The objectives of the paper are to solve the problem of a circumferentially-cracked cylindrical shell by taking into account the effect of transverse shear, and to obtain the stress intensity factors for the bending moment as well as the membrane force as the external load. The formulation of the problem is given for a specially orthotropic material within the framework of a linearized shallow shell theory. The particular theory used permits the consideration of all five boundary conditions as to moment and stress resultants on the crack surface. The effect of Poisson's ratio on the stress intensity factors and the nature of the out-of-plane displacement along the edges of the crack, i.e., bulging, are also studied.
El-Sharkawi, Mohammad Mostafa; Said, Galal Zaki
2012-02-01
The purpose of this study was to present our experience in treating dorso-lumbar tuberculosis by one-stage posterior circumferential fusion and to compare this group with a historical group treated by anterior debridement followed by postero-lateral fusion and stabilization. Between 2003 and 2008, 32 patients with active spinal tuberculosis were treated by one-stage posterior circumferential fusion and prospectively followed for a minimum of two years. Pain severity was measured using Visual Analogue Scale (VAS). Neurological assessment was done using the Frankel scale. The operative data, clinical, radiological, and functional outcomes were also compared to a similar group of 25 patients treated with anterior debridement and fusion, followed 10-14 days later by posterior stabilization and postero-lateral fusion. The mean operative time and duration of hospital stay were significantly longer in the two-stage group. The mean estimated blood loss was also larger, though insignificantly, in the two-stage group. The incidence of complications was significantly lower in the one-stage group. At final follow-up, all 34 patients with pre-operative neurological deficits showed at least one Frankel grade of neurological improvement, all 57 patients showed significant improvement of their VAS back pain score, the mean kyphotic angle has significantly improved, all patients achieved solid fusion and 43 (75.4%) patients returned to their pre-disease activity level or work. Instrumented circumferential fusion, whether in one or two stages, is an effective treatment for dorso-lumbar tuberculosis. One-stage surgery, however, is advantageous because it has lower complication rate, shorter hospital stay, less operative time and blood loss.
Sharma, Umesh; Yadav, Sher Singh; Tomar, Vinay; Garg, Amit
2016-01-01
This is a prospective study of the use and efficacy of a novel technique of circumferential tubularised lingual mucosal graft (LMG) in obliterative and near obliterative bulbar urethral stricture of >2 cm where excisional and augmented anastomotic urethroplasty are not feasible. The stenotic urethral segment was opened dorsally in midline and fibrosed urethra was excised taking care to preserve the healthy spongiosum tissue. LMG (av. Length 3 cm) was placed from one end of corporal body towards spongy tissue in a circumferential manner. Another LMG was placed in similar manner to deal with longer stricture. The urethra was tubularised over 14 Fr silicone catheter. A total of 12 men, of mean age 47 years underwent this procedure. The mean follow up period was 11 months starting from July 2014 till manuscript submission. Follow up included voiding cystourethrogram at 3 weeks, cystoscopy at 3 months (one patient didn't turned up) and subsequent follow up. Mean stricture length was 4.66 cm (range, 3-8.5 cm) and mean operative time was 195 min. (range, 160 to 200 min.). The technique was successful (normal voiding with no need for any post-operative procedure) in 11(91.6%) patients. One patient developed early recurrence at 4 month of surgery and had anastomotic stricture which was successfully managed by direct visual internal urethrotomy. Single stage circumferential tubularised graft urethroplasty is an excellent technique for strictures that include segments of obliterative and near obliterative diseased urethra. It provide a wider neourethra than patch graft urethroplasty.
Chadwick, W.W.; Jonsson, Sigurjon; Geist, Dennis J.; Poland, M.; Johnson, Daniel J.; Batt, S.; Harpp, Karen S.; Ruiz, A.
2011-01-01
The May 2005 eruption of Fernandina volcano, Galápagos, occurred along circumferential fissures parallel to the caldera rim and fed lava flows down the steep southwestern slope of the volcano for several weeks. This was the first circumferential dike intrusion ever observed by both InSAR and GPS measurements and thus provides an opportunity to determine the subsurface geometry of these enigmatic structures that are common on Galápagos volcanoes but are rare elsewhere. Pre- and post- eruption ground deformation between 2002 and 2006 can be modeled by the inflation of two separate magma reservoirs beneath the caldera: a shallow sill at ~1 km depth and a deeper point-source at ~5 km depth, and we infer that this system also existed at the time of the 2005 eruption. The co-eruption deformation is dominated by uplift near the 2005 eruptive fissures, superimposed on a broad subsidence centered on the caldera. Modeling of the co-eruption deformation was performed by including various combinations of planar dislocations to simulate the 2005 circumferential dike intrusion. We found that a single planar dike could not match both the InSAR and GPS data. Our best-fit model includes three planar dikes connected along hinge lines to simulate a curved concave shell that is steeply dipping (~45–60°) toward the caldera at the surface and more gently dipping (~12–14°) at depth where it connects to the horizontal sub-caldera sill. The shallow sill is underlain by the deep point source. The geometry of this modeled magmatic system is consistent with the petrology of Fernandina lavas, which suggest that circumferential eruptions tap the shallowest parts of the system, whereas radial eruptions are fed from deeper levels. The recent history of eruptions at Fernandina is also consistent with the idea that circumferential and radial intrusions are sometimes in a stress-feedback relationship and alternate in time with one another.
Roos, Viktoria; Klemm, Per
2006-01-01
Urinary tract infections (UTIs) are an important health problem worldwide, with many million cases each year. Escherichia coli is the most common organism causing UTIs in humans. The asymptomatic bacteriuria E. coli strain 83972 is an excellent colonizer of the human urinary tract, where it causes long-term bladder colonization. The strain has been used for prophylactic purposes in patients prone to more severe and recurrent UTIs. For this study, we used DNA microarrays to monitor the expression profile of strain 83972 in the human urinary tract. Significant differences in expression levels were seen between the in vivo expression profiles of strain 83972 in three patients and the corresponding in vitro expression profiles in lab medium and human urine. The data revealed an in vivo lifestyle of microaerobic growth with respiration of nitrate coupled to degradation of sugar acids and amino acids, with no signs of attachment to host tissues. Interestingly, genes involved in NO protection and metabolism showed significant up-regulation in the patients. This is one of the first studies to address bacterial whole-genome expression in humans and the first study to investigate global gene expression of an E. coli strain in the human urinary tract. PMID:16714589
Pedro, B; Stephenson, H; Linney, C; Cripps, P; Dukes-McEwan, J
2017-08-01
Assess global circumferential and radial systolic and diastolic myocardial function with speckle tracking echocardiography (STE) in healthy Great Danes (GD) and in GD diagnosed with dilated cardiomyopathy (DCM). Eighty-nine GD were included in the study: 39 healthy (normal group [NORMg]) and 50 diagnosed with DCM (DCMg). This was a retrospective study. Signalment and echocardiographic diagnosis were obtained from the medical records of GD assessed between 2008 and 2012. Speckle tracking echocardiography analysis of circumferential (C) and radial (R) strain (St) and strain rate (SR) in systole (S), early (E) and late (A) diastole was performed at the levels of the mitral valve (MV), papillary muscles (PM) and apex (Ap) of the left ventricle. Univariable and multivariable analysis was performed to identify differences between groups. Speckle tracking echocardiography variables increase from the MV towards the Ap of the left ventricle in both NORMg and DCMg dogs, some reaching statistical significance. Most of the variables (28/31) were lower in DCMg than in NORMg dogs: statistically significant variables included radial SR at the Ap in systole (p=0.029), radial strain at the PM (p=0.012), circumferential SR at the PM in systole (p=0.031), circumferential and radial SR at the MV in early diastole (p=0.019 and p=0.049, respectively). There are significant differences in STE variables between NORMg and DCMg Great Danes, although the overlap between the two groups may indicate that these variables are not sufficiently discriminatory. STE variables are not sufficiently sensitive to use in isolation as a screening method. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yadav, Ashwini Kumar; kumar, Ravi; Gupta, Akhilesh; Chatterjee, Barun; Mukhopadhyay, Deb; Lele, H. G.
2014-06-01
In a nuclear reactor temperature rises drastically in fuel channels under loss of coolant accident due to failure of primary heat transportation system. Present investigation has been carried out to capture circumferential and axial temperature gradients during fully and partially voiding conditions in a fuel channel using 19 pin fuel element simulator. A series of experiments were carried out by supplying power to outer, middle and center rods of 19 pin fuel simulator in ratio of 1.4:1.1:1. The temperature at upper periphery of pressure tube (PT) was slightly higher than at bottom due to increase in local equivalent thermal conductivity from top to bottom of PT. To simulate fully voided conditions PT was pressurized at 2.0 MPa pressure with 17.5 kW power injection. Ballooning initiated from center and then propagates towards the ends and hence axial temperature difference has been observed along the length of PT. For asymmetric heating, upper eight rods of fuel simulator were activated and temperature difference up-to 250 °C has been observed from top to bottom periphery of PT. Such situation creates steep circumferential temperature gradient over PT and could lead to breaching of PT under high pressure.
Utsunomiya, Hiroto; Yamamoto, Hideya; Kunita, Eiji; Hidaka, Takayuki; Kihara, Yasuki
2014-04-27
Insulin resistance, as a key mediator of metabolic syndrome, is thought to be associated with pathogenesis of calcific aortic valve disease and altered left ventricular (LV) function and structure. However, in patients with aortic valve sclerosis (AVS), the association between insulin resistance and subclinical impairment of LV function is not fully elucidated. We studied 57 patients (mean age 70 ± 8 years, 22 women) with asymptomatic AVS but normal LV ejection fraction in echocardiography. LV longitudinal and circumferential strain and strain rate was analyzed using two-dimensional speckle tracking echocardiography. Patients with uncontrolled hypertension and diabetes mellitus, chronic kidney disease, and concomitant coronary artery disease were excluded. They were divided into the insulin-resistant group (AVS+IR; N = 28) and no insulin-resistant group (AVS-IR; N = 29) according to the median value of homeostatic model assessment index. Computed tomography scans were also performed to measure the aortic valve calcium score and the visceral adipose tissue (VAT) area. In addition, age- and sex- adjusted 28 control subjects were recruited for the comparison. There were no significant differences in LV ejection fraction or mass index among the groups. The AVS+IR group had a higher aortic valve calcium score (median 94 versus 21, P = 0.022) and a larger VAT area (113 ± 42 cm2 versus 77 ± 38 cm2, P = 0.001) than the AVS-IR group. Notably, LV global longitudinal strain, strain rate (SR), and early diastolic SR were significantly lower in the AVS+IR group than in the AVS-IR group and in control subjects (strain: -16.2 ± 1.6% versus -17.2 ± 1.2% and -18.9 ± 0.8%; SR: -1.18 ± 0.26 s(-1) versus -1.32 ± 0.21 s(-1) and -1.52 ± 0.08 s(-1); early diastolic SR: -1.09 ± 0.23 s(-1) versus -1.23 ± 0.18 s(-1) and -1.35 ± 0.12 s(-1); P < 0.05 for all comparison), whereas circumferential function were not
2014-01-01
Background Insulin resistance, as a key mediator of metabolic syndrome, is thought to be associated with pathogenesis of calcific aortic valve disease and altered left ventricular (LV) function and structure. However, in patients with aortic valve sclerosis (AVS), the association between insulin resistance and subclinical impairment of LV function is not fully elucidated. Methods We studied 57 patients (mean age 70 ± 8 years, 22 women) with asymptomatic AVS but normal LV ejection fraction in echocardiography. LV longitudinal and circumferential strain and strain rate was analyzed using two-dimensional speckle tracking echocardiography. Patients with uncontrolled hypertension and diabetes mellitus, chronic kidney disease, and concomitant coronary artery disease were excluded. They were divided into the insulin-resistant group (AVS+IR; N = 28) and no insulin-resistant group (AVS-IR; N = 29) according to the median value of homeostatic model assessment index. Computed tomography scans were also performed to measure the aortic valve calcium score and the visceral adipose tissue (VAT) area. In addition, age- and sex- adjusted 28 control subjects were recruited for the comparison. Results There were no significant differences in LV ejection fraction or mass index among the groups. The AVS+IR group had a higher aortic valve calcium score (median 94 versus 21, P = 0.022) and a larger VAT area (113 ± 42 cm2 versus 77 ± 38 cm2, P = 0.001) than the AVS-IR group. Notably, LV global longitudinal strain, strain rate (SR), and early diastolic SR were significantly lower in the AVS+IR group than in the AVS-IR group and in control subjects (strain: -16.2 ± 1.6% versus -17.2 ± 1.2% and -18.9 ± 0.8%; SR: -1.18 ± 0.26 s-1 versus -1.32 ± 0.21 s-1 and -1.52 ± 0.08 s-1; early diastolic SR: -1.09 ± 0.23 s-1 versus -1.23 ± 0.18 s-1 and -1.35 ± 0.12 s-1; P < 0.05 for all comparison), whereas
Simpson, G S; Eardley, N; McNicol, F; Healey, P; Hughes, M; Rooney, P S
2014-05-01
The management of rectal cancer relies on accurate MRI staging. Multi-modal treatments can downstage rectal cancer prior to surgery and may have an effect on MRI accuracy. We aim to correlate the findings of MRI staging of rectal cancer with histological analysis, the effect of neoadjuvant therapy on this and the implications of circumferential resection margin (CRM) positivity following neoadjuvant therapy. An analysis of histological data and radiological staging of all cases of rectal cancer in a single centre between 2006 and 2011 were conducted. Two hundred forty-one patients had histologically proved rectal cancer during the study period. One hundred eighty-two patients underwent resection. Median age was 66.6 years, and male to female ratio was 13:5. R1 resection rate was 11.1%. MRI assessments of the circumferential resection margin in patients without neoadjuvant radiotherapy were 93.6 and 88.1% in patients who underwent neoadjuvant radiotherapy. Eighteen patients had predicted positive margins following chemoradiotherapy, of which 38.9% had an involved CRM on histological analysis. MRI assessment of the circumferential resection margin in rectal cancer is associated with high accuracy. Neoadjuvant chemoradiotherapy has a detrimental effect on this accuracy, although accuracy remains high. In the presence of persistently predicted positive margins, complete resection remains achievable but may necessitate a more radical approach to resection.
Stress and strain provide positional and directional cues in development.
Bozorg, Behruz; Krupinski, Pawel; Jönsson, Henrik
2014-01-01
The morphogenesis of organs necessarily involves mechanical interactions and changes in mechanical properties of a tissue. A long standing question is how such changes are directed on a cellular scale while being coordinated at a tissular scale. Growing evidence suggests that mechanical cues are participating in the control of growth and morphogenesis during development. We introduce a mechanical model that represents the deposition of cellulose fibers in primary plant walls. In the model both the degree of material anisotropy and the anisotropy direction are regulated by stress anisotropy. We show that the finite element shell model and the simpler triangular biquadratic springs approach provide equally adequate descriptions of cell mechanics in tissue pressure simulations of the epidermis. In a growing organ, where circumferentially organized fibers act as a main controller of longitudinal growth, we show that the fiber direction can be correlated with both the maximal stress direction and the direction orthogonal to the maximal strain direction. However, when dynamic updates of the fiber direction are introduced, the mechanical stress provides a robust directional cue for the circumferential organization of the fibers, whereas the orthogonal to maximal strain model leads to an unstable situation where the fibers reorient longitudinally. Our investigation of the more complex shape and growth patterns in the shoot apical meristem where new organs are initiated shows that a stress based feedback on fiber directions is capable of reproducing the main features of in vivo cellulose fiber directions, deformations and material properties in different regions of the shoot. In particular, we show that this purely mechanical model can create radially distinct regions such that cells expand slowly and isotropically in the central zone while cells at the periphery expand more quickly and in the radial direction, which is a well established growth pattern in the meristem.
Components of variation of surface hoof strain with time.
Thomason, J J; Bignell, W W; Sears, W
2001-04-01
The relative contribution of a number of random and fixed variables to variation in surface strain magnitudes on the hoof capsule was assessed for healthy feet under normal conditions. Principal strains were recorded in vivo from 5 rosette gauges glued around the circumference of the right forefeet of 4 horses on 4 occasions over a 9 month period. Recordings were made at every other trimming and reshoeing. During each session, gauges were positioned with a template for repeatability. Strains were recorded at the trot and canter (at consistent speeds), for straight motion and turns, and before and after the hoof was trimmed and reset. Up to 30 strides were recorded for each combination of these variables. ANOVAs were performed on midstance strains of 7008 strides to determine the relative contributions to strain variation of individual horse, test day, gait and direction combined as one factor, gauge position on the hoof, trimming, interstride variability and the interactions among these factors. The ANOVA model explained 87% of the variation, of which approximately 84% was due to fixed effects and 16% to random effects. Circumferential position of the gauges and several of the interactions including this term were by far the greatest contributors to strain variation. Differences among gauge positions, individuals and gait + direction are consistent with previous work. This study has added the relative effects, which are small but significant, of trimming on a regular basis and of time. The change in strain magnitudes with trimming was different for each horse, which leads to the possibility that over- and underuse may have to be quantified on an individual basis.
Lu, Ming; Shi, Guang-Ying; Wang, Guo-Qiang; Wu, Yan; Liu, Yang; Wen, Hao
2013-08-14
To identify a more effective treatment protocol for circumferential mixed hemorrhoids. A total of 192 patients with circumferential mixed hemorrhoids were randomized into the treatment group, where they underwent Milligan-Morgan hemorrhoidectomy with anal cushion suspension and partial internal sphincter resection, or the control group, where traditional external dissection and internal ligation were performed. Postoperative recovery and complications were monitored. The time to wound healing was 12.96 ± 2.25 d in the treatment group shorter than 19.58 ± 2.71 d in the control group. Slight pain rate was 58.3% in the treatment group higher than 22.9% in the control group; moderate pain rate was 33.3% in the treatment group lower than 56.3% in the control group severe pain rate was 8.4% in the treatment group lower than 20.8% in the control group. No edema rate was 70.8% in the treatment group higher than 43.8% in the control group; mild local edema rate was 26% in the treatment group lower than 39.6% in the control group obvious local edema was 3.03% in the treatment group lower than 16.7% in the control group. No stenosis rate was 85.4% in the treatment group higher than 63.5% in the control group; moderate stenosis rate was 14.6% in the treatment group Lower than 27.1% in the control group severe anal stenosis rate was 0% in the treatment group lower than 9.4% in the control group. Milligan-Morgan hemorrhoidectomy with anal cushion suspension and partial internal sphincter resection is the optimal treatment for circumferential mixed hemorrhoids and can be widely applied in clinical settings.
Le, Yuan; Stein, Ashley; Berry, Colin; Kellman, Peter; Bennett, Eric E.; Taylor, Joni; Lucas, Katherine; Kopace, Rael; Chefd’Hotel, Christophe; Lorenz, Christine H.; Croisille, Pierre; Wen, Han
2010-01-01
The purpose of this study is to develop and evaluate a displacement-encoded pulse sequence for simultaneous perfusion and strain imaging. Displacement-encoded images in 2–3 myocardial slices were repeatedly acquired using a single shot pulse sequence for 3 to 4 minutes, which covers a bolus infusion of Gd. The magnitudes of the images were T1 weighted and provided quantitative measures of perfusion, while the phase maps yielded strain measurements. In an acute coronary occlusion swine protocol (n=9), segmental perfusion measurements were validated against microsphere reference standard with a linear regression (slope 0.986, R2 = 0.765, Bland-Altman standard deviation = 0.15 ml/min/g). In a group of ST-elevation myocardial infarction(STEMI) patients (n=11), the scan success rate was 76%. Short-term contrast washout rate and perfusion are highly correlated (R2=0.72), and the pixel-wise relationship between circumferential strain and perfusion was better described with a sigmoidal Hill curve than linear functions. This study demonstrates the feasibility of measuring strain and perfusion from a single set of images. PMID:20544714
A rhythmic motor pattern activated by circumferential stretch in guinea-pig distal colon.
Spencer, Nick J; Hennig, Grant W; Smith, Terence K
2002-12-01
Simultaneous intracellular recordings were made from pairs of circular muscle (CM) cells, at the oral and anal ends of a segment of guinea-pig distal colon, to investigate the neuronal mechanisms underlying faecal pellet propulsion. When a minimum degree of circumferential stretch was applied to sheet preparations of colon, recordings from CM cells revealed either no ongoing junction potentials, or alternatively, small potentials usually < 5 mV in amplitude. Maintained circumferential stretch applied to these preparations evoked an ongoing discharge of excitatory junction potentials (EJPs) at the oral recording site (range: 1-25 mV), which lasted for up to 6 h. The onset of each large oral EJP was time-locked with the onset of an inhibitory junction potential (IJP) at an anal recording electrode, located 2 cm from the oral recording. Similar results were obtained in isolated intact tube preparations of colon, when recordings were made immediately oral and anal of an artificial faecal pellet. The amplitudes of many large (> 5 mV) oral EJPs were linearly related to the amplitudes of anal IJPs occurring 20 mm apart. In the absence of an L-type Ca(2+) channel blocker, action potentials occurred on each large oral EJP. Synchronized discharges of stretch-activated EJPs and IJPs were preserved following pretreatment with capsaicin (10 microM), were unaffected by nifedipine (1 microM) and did not require the mucosa or submucous plexus. EJPs and IJPs were abolished by hexamethonium (300 microM) or tetrodotoxin (1 microM), but persisted in the presence of pyridoxal phosphate-6-azophenyl-2',4'-disulphonic acid (PPADS; 10 microM) or an NK(3) tachykinin receptor antagonist (Neurokinin A 4-10; 100 nM to 5 microM). In summary, maintained circumferential stretch of the distal colon activates a population of intrinsic mechanosensory neurons that generate repetitive firing of ascending excitatory and descending inhibitory pathways to CM. These mechanosensory neurons, which may be
A rhythmic motor pattern activated by circumferential stretch in guinea-pig distal colon
Spencer, Nick J; Hennig, Grant W; Smith, Terence K
2002-01-01
Simultaneous intracellular recordings were made from pairs of circular muscle (CM) cells, at the oral and anal ends of a segment of guinea-pig distal colon, to investigate the neuronal mechanisms underlying faecal pellet propulsion. When a minimum degree of circumferential stretch was applied to sheet preparations of colon, recordings from CM cells revealed either no ongoing junction potentials, or alternatively, small potentials usually < 5 mV in amplitude. Maintained circumferential stretch applied to these preparations evoked an ongoing discharge of excitatory junction potentials (EJPs) at the oral recording site (range: 1-25 mV), which lasted for up to 6 h. The onset of each large oral EJP was time-locked with the onset of an inhibitory junction potential (IJP) at an anal recording electrode, located 2 cm from the oral recording. Similar results were obtained in isolated intact tube preparations of colon, when recordings were made immediately oral and anal of an artificial faecal pellet. The amplitudes of many large (> 5 mV) oral EJPs were linearly related to the amplitudes of anal IJPs occurring 20 mm apart. In the absence of an L-type Ca2+ channel blocker, action potentials occurred on each large oral EJP. Synchronized discharges of stretch-activated EJPs and IJPs were preserved following pretreatment with capsaicin (10 μm), were unaffected by nifedipine (1 μm) and did not require the mucosa or submucous plexus. EJPs and IJPs were abolished by hexamethonium (300 μm) or tetrodotoxin (1 μm), but persisted in the presence of pyridoxal phosphate-6-azophenyl-2′,4′-disulphonic acid (PPADS; 10 μm) or an NK3 tachykinin receptor antagonist (Neurokinin A 4-10; 100 nm to 5 μm). In summary, maintained circumferential stretch of the distal colon activates a population of intrinsic mechanosensory neurons that generate repetitive firing of ascending excitatory and descending inhibitory pathways to CM. These mechanosensory neurons, which may be interneurons, are
Tensile characterisation of the aorta across quasi-static to blast loading strain rates
NASA Astrophysics Data System (ADS)
Magnus, Danyal; Proud, William; Haller, Antoine; Jouffroy, Apolline
2017-06-01
The dynamic tensile failure mechanisms of the aorta during Traumatic Aortic Injury (TAI) are poorly understood. In automotive incidents, where the aorta may be under strains of the order of 100/s, TAI is the second largest cause of mortality. In these studies, the proximal descending aorta is the most common site where rupture is observed. In particular, the transverse direction is most commonly affected due to the circumferential orientation of elastin, and hence the literature generally concentrates upon axial samples. This project extends these dynamic studies to the blast loading regime where strain-rates are of the order of 1000/s. A campaign of uniaxial tensile experiments are conducted at quasi-static, intermediate (drop-weight) and high (tensile Split-Hopkinson Pressure Bar) strain rates. In each case, murine and porcine aorta models are considered and the extent of damage assessed post-loading using histology. Experimental data will be compared against current viscoelastic models of the aorta under axial stress. Their applicability across strain rates will be discussed. Using a multi-disciplinary approach, the conditions applied to the samples replicate in vivo conditions, employing a blood simulant-filled tubular specimen surrounded by a physiological solution.
2018-01-01
ABSTRACT Bacterial genomes sometimes contain genes that code for homologues of global regulators, the function of which is unclear. In members of the family Enterobacteriaceae, cells express the global regulator H-NS and its paralogue StpA. In Escherichia coli, out of providing a molecular backup for H-NS, the role of StpA is poorly characterized. The enteroaggregative E. coli strain 042 carries, in addition to the hns and stpA genes, a third gene encoding an hns paralogue (hns2). We present in this paper information about its biological function. Transcriptomic analysis has shown that the H-NS2 protein targets a subset of the genes targeted by H-NS. Genes targeted by H-NS2 correspond mainly with horizontally transferred (HGT) genes and are also targeted by the Hha protein, a fine-tuner of H-NS activity. Compared with H-NS, H-NS2 expression levels are lower. In addition, H-NS2 expression exhibits specific features: it is sensitive to the growth temperature and to the nature of the culture medium. This novel H-NS paralogue is widespread within the Enterobacteriaceae. IMPORTANCE Global regulators such as H-NS play key relevant roles enabling bacterial cells to adapt to a changing environment. H-NS modulates both core and horizontally transferred (HGT) genes, but the mechanism by which H-NS can differentially regulate these genes remains to be elucidated. There are several instances of bacterial cells carrying genes that encode homologues of the global regulators. The question is what the roles of these proteins are. We noticed that the enteroaggregative E. coli strain 042 carries a new hitherto uncharacterized copy of the hns gene. We decided to investigate why this pathogenic E. coli strain requires an extra H-NS paralogue, termed H-NS2. In our work, we show that H-NS2 displays specific expression and regulatory properties. H-NS2 targets a subset of H-NS-specific genes and may help to differentially modulate core and HGT genes by the H-NS cellular pool. PMID
Prieto, A; Bernabeu, M; Aznar, S; Ruiz-Cruz, S; Bravo, A; Queiroz, M H; Juárez, A
2018-01-01
Bacterial genomes sometimes contain genes that code for homologues of global regulators, the function of which is unclear. In members of the family Enterobacteriaceae , cells express the global regulator H-NS and its paralogue StpA. In Escherichia coli , out of providing a molecular backup for H-NS, the role of StpA is poorly characterized. The enteroaggregative E. coli strain 042 carries, in addition to the hns and stpA genes, a third gene encoding an hns paralogue ( hns2 ). We present in this paper information about its biological function. Transcriptomic analysis has shown that the H-NS2 protein targets a subset of the genes targeted by H-NS. Genes targeted by H-NS2 correspond mainly with horizontally transferred (HGT) genes and are also targeted by the Hha protein, a fine-tuner of H-NS activity. Compared with H-NS, H-NS2 expression levels are lower. In addition, H-NS2 expression exhibits specific features: it is sensitive to the growth temperature and to the nature of the culture medium. This novel H-NS paralogue is widespread within the Enterobacteriaceae . IMPORTANCE Global regulators such as H-NS play key relevant roles enabling bacterial cells to adapt to a changing environment. H-NS modulates both core and horizontally transferred (HGT) genes, but the mechanism by which H-NS can differentially regulate these genes remains to be elucidated. There are several instances of bacterial cells carrying genes that encode homologues of the global regulators. The question is what the roles of these proteins are. We noticed that the enteroaggregative E. coli strain 042 carries a new hitherto uncharacterized copy of the hns gene. We decided to investigate why this pathogenic E. coli strain requires an extra H-NS paralogue, termed H-NS2. In our work, we show that H-NS2 displays specific expression and regulatory properties. H-NS2 targets a subset of H-NS-specific genes and may help to differentially modulate core and HGT genes by the H-NS cellular pool.
Qian, Pierre; Barry, Michael Anthony; Nguyen, Trang; Ross, David; Kovoor, Pramesh; McEwan, Alistair; Thomas, Stuart; Thiagalingam, Aravinda
2015-07-01
Pulmonary vein isolation is an effective treatment for atrial fibrillation. Current endocardial ablation techniques require catheter contact for lesion formation. Inadequate or inconsistent catheter contact results in difficulty with achieving acute and long-term isolation and consequent atrial arrhythmia recurrence. Microwave energy produces radiant heating and therefore can be used for noncontact catheter ablation. We hypothesized that it is possible to design a microwave catheter to produce a circumferential transmural thermal lesion in an in vitro model of a pulmonary vein antrum. A monopole microwave catheter with a sideways firing axially symmetrical heating pattern was designed. Noncontact ablations were performed in a perfused pulmonary vein model constructed from microwave myocardial phantom embedded with a sheet of thermochromic liquid crystal to permit visualization and measurement of thermal lesions from color changes. 1200 J ablations were performed at 150 W for 80 seconds and 120 W for 100 seconds at high (0.8 L/min) and low (0.06 L/min) flow through the modeled pulmonary vein. Myocardial tissue was substituted for the phantom material and ablations repeated at 150 W for 180 seconds and stained with nitro-blue tetrazolium. The catheter was able to induce deep circumferential antral lesions in myocardial phantom and myocardial tissue. Higher power and shorter ablations delivering the same amount of microwave energy resulted in larger lesions with less surface sparing. A microwave catheter can be designed to produce a circumferential thermal lesion on noncontact ablation and may have possible applications for pulmonary vein isolation. © 2015 Wiley Periodicals, Inc.
Association of comorbidity burden with abnormal cardiac mechanics: findings from the HyperGEN study.
Selvaraj, Senthil; Aguilar, Frank G; Martinez, Eva E; Beussink, Lauren; Kim, Kwang-Youn A; Peng, Jie; Rasmussen-Torvik, Laura; Sha, Jin; Irvin, Marguerite R; Gu, C Charles; Lewis, Cora E; Hunt, Steven C; Arnett, Donna K; Shah, Sanjiv J
2014-04-29
Comorbidities are common in heart failure (HF), and the number of comorbidities has been associated with poor outcomes in HF patients. However, little is known about the effect of multiple comorbidities on cardiac mechanics, which could impact the pathogenesis of HF. We sought to determine the relationship between comorbidity burden and adverse cardiac mechanics. We performed speckle-tracking analysis on echocardiograms from the HyperGEN study (n=2150). Global longitudinal, circumferential, and radial strain, and early diastolic (e') tissue velocities were measured. We evaluated the association between comorbidity number and cardiac mechanics using linear mixed effects models to account for relatedness among subjects. The mean age was 51 ± 14 years, 58% were female, and 47% were African American. Dyslipidemia and hypertension were the most common comorbidities (61% and 58%, respectively). After adjusting for left ventricular (LV) mass index, ejection fraction, and several potential confounders, the number of comorbidities remained associated with all indices of cardiac mechanics except global circumferential strain (eg, β=-0.32 [95% CI -0.44, -0.20] per 1-unit increase in number of comorbidities for global longitudinal strain; β=-0.16 [95% CI -0.20, -0.11] for e' velocity; P ≤ 0.0001 for both comparisons). Results were similar after excluding participants with abnormal LV geometry (P<0.05 for all comparisons). Higher comorbidity burden is associated with worse cardiac mechanics, even in the presence of normal LV geometry. The deleterious effect of multiple comorbidities on cardiac mechanics may explain both the high comorbidity burden and adverse outcomes in patients who ultimately develop HF.
Kim, Chee Hae; Wang, Shuang; Park, Jun-Bean; Jung, Keun-Hwa; Yoon, Yeonyee E; Lee, Seung-Pyo; Kim, Hyung-Kwan; Kim, Yong-Jin; Cho, Goo-Yeong; Sohn, Dae-Won
2018-03-07
Speckle-tracking imaging has been introduced for the precise assessment of vessel mechanics. However, there are no data on the role of this imaging tool in assessing the changes in vasculature with statin therapy, which is known to enhance vascular elasticity. This study was a prospective study including 48 statin-naïve patients (age, 58.2±8.4 years; 29.2% male) with hypercholesterolemia. Circumferential carotid artery strain (CAS) and stiffness index (β 2 ) were measured using speckle-tracking imaging before and after 3 months of high-dose pitavastatin treatment (4 mg daily). For the comparison, we measured conventional carotid elasticity parameters and intima-media thickness using B-mode ultrasound at the same time points. Compared with baseline, there was significant improvement in circumferential CAS (2.98%±1.18% to 3.40%±1.43%, p=0.008) and β 2 (0.19±0.07 to 0.17±0.08, p=0.047) after statin therapy. Contrariwise, there were no significant changes in all conventional carotid elasticity metrics and intima-media thickness. When stratifying patients into two subgroups by 10 year atherosclerotic cardiovascular disease (ASCVD) risk, speckle-tracking-derived circumferential CAS and β 2 improved significantly only in patients with ASCVD risk ≥ 7.5%. Short-term treatment with high-dose pitavastatin improved carotid artery elasticity measured by speckle-tracking method, but not conventional parameters by B-mode ultrasound. Speckle-tracking-based measurements may allow the early noninvasive assessment of statin effects on vascular function in hypercholesterolemic patients.
Voeller, Rochus K.; Aziz, Abdulhameed; Maniar, Hersh S.; Ufere, Nneka N.; Taggar, Ajay K.; Bernabe, Noel J.; Cupps, Brian P.
2011-01-01
Increased right atrial (RA) and ventricular (RV) chamber volumes are a late maladaptive response to chronic pulmonary hypertension. The purpose of the current investigation was to characterize the early compensatory changes that occur in the right heart during chronic RV pressure overload before the development of chamber dilation. Magnetic resonance imaging with radiofrequency tissue tagging was performed on dogs at baseline and after 10 wk of pulmonary artery banding to yield either mild RV pressure overload (36% rise in RV pressure; n = 5) or severe overload (250% rise in RV pressure; n = 4). The RV free wall was divided into three segments within a midventricular plane, and circumferential myocardial strain was calculated for each segment, the septum, and the left ventricle. Chamber volumes were calculated from stacked MRI images, and RA mechanics were characterized by calculating the RA reservoir, conduit, and pump contribution to RV filling. With mild RV overload, there were no changes in RV strain or RA function. With severe RV overload, RV circumferential strain diminished by 62% anterior (P = 0.04), 42% inferior (P = 0.03), and 50% in the septum (P = 0.02), with no change in the left ventricle (P = 0.12). RV filling became more dependent on RA conduit function, which increased from 30 ± 9 to 43 ± 13% (P = 0.01), than on RA reservoir function, which decreased from 47 ± 6 to 33 ± 4% (P = 0.04), with no change in RA pump function (P = 0.94). RA and RV volumes and RV ejection fraction were unchanged from baseline during either mild (P > 0.10) or severe RV pressure overload (P > 0.53). In response to severe RV pressure overload, RV myocardial strain is segmentally diminished and RV filling becomes more dependent on RA conduit rather than reservoir function. These compensatory mechanisms of the right heart occur early in chronic RV pressure overload before chamber dilation develops. PMID:21926343
Lu, Ming; Shi, Guang-Ying; Wang, Guo-Qiang; Wu, Yan; Liu, Yang; Wen, Hao
2013-01-01
AIM: To identify a more effective treatment protocol for circumferential mixed hemorrhoids. METHODS: A total of 192 patients with circumferential mixed hemorrhoids were randomized into the treatment group, where they underwent Milligan-Morgan hemorrhoidectomy with anal cushion suspension and partial internal sphincter resection, or the control group, where traditional external dissection and internal ligation were performed. Postoperative recovery and complications were monitored. RESULTS: The time to wound healing was 12.96 ± 2.25 d in the treatment group shorter than 19.58 ± 2.71 d in the control group. Slight pain rate was 58.3% in the treatment group higher than 22.9% in the control group; moderate pain rate was 33.3% in the treatment group lower than 56.3% in the control group severe pain rate was 8.4% in the treatment group lower than 20.8% in the control group. No edema rate was 70.8% in the treatment group higher than 43.8% in the control group; mild local edema rate was 26% in the treatment group lower than 39.6% in the control group obvious local edema was 3.03% in the treatment group lower than 16.7% in the control group. No stenosis rate was 85.4% in the treatment group higher than 63.5% in the control group; moderate stenosis rate was 14.6% in the treatment group Lower than 27.1% in the control group severe anal stenosis rate was 0% in the treatment group lower than 9.4% in the control group. CONCLUSION: Milligan-Morgan hemorrhoidectomy with anal cushion suspension and partial internal sphincter resection is the optimal treatment for circumferential mixed hemorrhoids and can be widely applied in clinical settings. PMID:23946609
Stochastic precision analysis of 2D cardiac strain estimation in vivo
NASA Astrophysics Data System (ADS)
Bunting, E. A.; Provost, J.; Konofagou, E. E.
2014-11-01
Ultrasonic strain imaging has been applied to echocardiography and carries great potential to be used as a tool in the clinical setting. Two-dimensional (2D) strain estimation may be useful when studying the heart due to the complex, 3D deformation of the cardiac tissue. Increasing the framerate used for motion estimation, i.e. motion estimation rate (MER), has been shown to improve the precision of the strain estimation, although maintaining the spatial resolution necessary to view the entire heart structure in a single heartbeat remains challenging at high MERs. Two previously developed methods, the temporally unequispaced acquisition sequence (TUAS) and the diverging beam sequence (DBS), have been used in the past to successfully estimate in vivo axial strain at high MERs without compromising spatial resolution. In this study, a stochastic assessment of 2D strain estimation precision is performed in vivo for both sequences at varying MERs (65, 272, 544, 815 Hz for TUAS; 250, 500, 1000, 2000 Hz for DBS). 2D incremental strains were estimated during left ventricular contraction in five healthy volunteers using a normalized cross-correlation function and a least-squares strain estimator. Both sequences were shown capable of estimating 2D incremental strains in vivo. The conditional expected value of the elastographic signal-to-noise ratio (E(SNRe|ɛ)) was used to compare strain estimation precision of both sequences at multiple MERs over a wide range of clinical strain values. The results here indicate that axial strain estimation precision is much more dependent on MER than lateral strain estimation, while lateral estimation is more affected by strain magnitude. MER should be increased at least above 544 Hz to avoid suboptimal axial strain estimation. Radial and circumferential strain estimations were influenced by the axial and lateral strain in different ways. Furthermore, the TUAS and DBS were found to be of comparable precision at similar MERs.
Catry, Jonathan; Luong-Nguyen, Minh; Arakelian, Lousineh; Poghosyan, Tigran; Bruneval, Patrick; Domet, Thomas; Michaud, Laurent; Sfeir, Rony; Gottrand, Frederic; Larghero, Jerome; Vanneaux, Valerie
2018-01-01
Tissue engineering appears promising as an alternative technique for esophageal replacement. Mesenchymal stem cells (MSCs) could be of interest for esophageal regeneration. Evaluation of the ability of an acellular matrix seeded with autologous MSCs to promote tissue remodeling toward an esophageal phenotype after circumferential replacement of the esophagus in a mini pig model. A 3 cm long circumferential replacement of the abdominal esophagus was performed with an MSC-seeded matrix (MSC group, n = 10) versus a matrix alone (control group, n = 10), which has previously been matured into the great omentum. The graft area was covered with an esophageal removable stent. A comparative histological analysis of the graft area after animals were euthanized sequentially is the primary outcome of the study. Histological findings after maturation, overall animal survival, and postoperative morbidity were also compared between groups. At postoperative day 45 (POD 45), a mature squamous epithelium covering the entire surface of the graft area was observed in all the MSC group specimens but in none of the control group before POD 95. Starting at POD 45, desmin positive cells were seen in the graft area in the MSC group but never in the control group. There were no differences between groups in the incidence of surgical complications and postoperative death. In this model, MSCs accelerate the mature re-epitheliazation and early initiation of muscle cell colonization. Further studies will focus on the use of cell tracking tools in order to analyze the becoming of these cells and the mechanisms involved in this tissue regeneration. PMID:29390879
Bobby Kannan, M; Singh Raman, R K; Witte, F; Blawert, C; Dietzel, W
2011-02-01
Applications of magnesium alloys as biodegradable orthopaedic implants are critically dependent on the mechanical integrity of the implant during service. In this study, the mechanical integrity of an AZ91 magnesium alloy was studied using a constant extension rate tensile (CERT) method. The samples in two different geometries that is, circumferentially notched (CN), and circumferentially notched and fatigue cracked (CNFC), were tested in air and in simulated body fluid (SBF). The test results show that the mechanical integrity of the AZ91 magnesium alloy decreased substantially (∼50%) in both the CN and CNFC samples exposed to SBF. Fracture surface analysis revealed secondary cracks suggesting stress corrosion cracking susceptibility of the alloy in SBF. Copyright © 2010 Wiley Periodicals, Inc.
Research on Strain Measurements of Core Positions for the Chinese Space Station.
Shen, Jingshi; Zeng, Xiaodong; Luo, Yuxiang; Cao, Changqing; Wang, Ting
2018-06-05
The Chinese space station is designed to carry out manned spaceflight, space science research, and so on. In serious applications, it is a common operation to inject gas into the hull, which can produce strain of the bulkhead. Accurate measurement of strain for the bulkhead is one of the key tasks in evaluating the health condition of the space station. This is the first work to perform strain detection for the Chinese space station bulkhead by using optical fiber Bragg grating. In the period of measurements, the resistance strain gauge is used as the strain standard. The measurement error of the fiber optical sensor in the circumferential direction is very small, being less than 4.52 με. However, the error in the axial direction is very large with the highest value of 28.93 με. Because the measurement error of bare fiber in the axial direction is very small, the transverse effect of the substrate of the fiber optical sensor likely plays a role. The comparison of the theoretical and experimental results of the transverse effect coefficients shows that they are fairly consistent, with values of 0.0271 and 0.0287, respectively. After the transverse effect is compensated, the strain deviation in the axial detection is smaller than 2.04 με. It is of great significance to carry out real-time health assessment for the bulkhead of the space station.
Global Longitudinal Strain to Predict Mortality in Patients With Acute Heart Failure.
Park, Jin Joo; Park, Jun-Bean; Park, Jae-Hyeong; Cho, Goo-Yeong
2018-05-08
Heart failure (HF) is currently classified according to left ventricular ejection fraction (LVEF); however, the prognostic value of LVEF is controversial. Myocardial strain is a prognostic factor independently of LVEF. The authors sought to evaluate the prognostic value of global longitudinal strain (GLS) in patients with HF. GLS was measured in 4,172 consecutive patients with acute HF. Patients were categorized as either HF with reduced (LVEF <40%), midrange (LVEF 40% to 49%), or preserved ejection fraction (LVEF ≥50%) and were also classified as having mildly (GLS >12.6%), moderately (8.1% < GLS <12.5%), or severely (GLS ≤8.0%) reduced strain. The primary endpoint was 5-year all-cause mortality. Mean GLS was 10.8%, and mean LVEF was 40%. Overall, 1,740 (40.4%) patients had died at 5 years. Patients with reduced ejection fraction had slightly higher mortality than those with midrange or preserved ejection fraction (41%, 38%, and 39%, respectively; log-rank p = 0.031), whereas patients with reduced strain had significantly higher mortality (severely reduced GLS, 49%; moderately reduced GLS, 38%; mildly reduced GLS, 34%; log-rank p < 0.001). In multivariable analysis, each 1% increase in GLS was associated with a 5% decreased risk for mortality (p < 0.001). Patients with moderate (hazard ratio: 1.31; 95% confidence interval: 1.13 to 1.53) and severe GLS reductions (hazard ratio: 1.61; 95% confidence interval: 1.36 to 1.91) had higher mortality, but LVEF was not associated with mortality. In patients with acute HF, GLS has greater prognostic value than LVEF. Therefore, the authors suggest that GLS should be considered as the standard measurement in all patients with HF. This new concept needs validation in further studies. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Circumferential skin folds in a child: a case of Michelin tire baby syndrome.
Palit, Aparna; Inamadar, Arun C
2007-01-01
A six-month-old girl who presented with dermatitis was found to have multiple, symmetric, deep, gyrate skin folds involving her trunk and similar circumferential lesions on her extremities since birth. She had a characteristic round face with hypertelorism, depressed nasal bridge, thin, down-turned vermillion border of upper lip and short neck. Skin biopsy demonstrated increased smooth muscle fibers in the deeper dermis. A diagnosis of Michelin tire baby syndrome was made. Clinical features, histopathology, differential diagnosis and prognosis of this rare disorder have been discussed.
Hoff, Eike K; Strube, Patrick; Pumberger, Matthias; Zahn, Robert K; Putzier, Michael
2016-05-01
Prospective, randomized trial. The treatment of degenerative disc disease (DDD) with two-level fusion has been associated with a reasonable rate of complications. The aim of the present study was to compare (Hybrid) stand-alone anterior lumbar interbody fusion (ALIF) at L5/S1 with total disc replacement at L4/5 (TDR) as an alternative surgical strategy to (Fusion) 2-level circumferential fusion employing transforaminal lumbar interbody fusion (TLIF) with transpedicular stabilization at L4-S1. A total of 62 patients with symptomatic DDD of segments L5/S1 (Modic ≥2°) and L4/5 (Modic ≤2°; positive discography) were enrolled; 31 were treated with Hybrid and 31 with Fusion. Preoperatively, at 0, 12, and a mean follow-up of 37 months, clinical (ODI, VAS) and radiological evaluations (plain/extension-flexion radiographs evaluated for implant failure, fusion, global and segmental lordosis, and ROM) were performed. In 26 of 31 Hybrid and 24 of 31 Fusion patients available at the final follow-up, we found a significant clinical improvement compared to preoperatively. Hybrid patients had significantly lower VAS scores immediately postoperatively and at follow-up compared to Fusion patients. The complication rates were low and similar between the groups. Lumbar lordosis increased in both groups. The increase was mainly located at L4-S1 in the Hybrid group and at L1-L4 in the Fusion group. Hybrid patients presented with increased ROM at L4/5 and L3/4, and Fusion patients presented with increased ROM at L3/4, with significantly greater ROM at L3/4 compared to Hybrid patients at follow-up. Hybrid surgery is a viable surgical alternative for the presented indication. Approach-related inferior trauma and the balanced restoration of lumbar lordosis resulted in superior clinical outcomes compared to two-level circumferential fusion with TLIF.
Sengupta, Shantanu P.; Jaju, Rahul; Nugurwar, Abhijeet; Caracciolo, Giuseppe; Sengupta, Partho P.
2012-01-01
Background The status of left ventricle in sickle cell anemia presenting in sickle crisis and follow up has been minimally studied in past. To determine the left ventricular (LV) myocardial performance in these patients, we performed the study to assess two dimensional strains imaging which allowed a rapid and an accurate analysis of global and regional LV myocardial performance in longitudinal, radial, and circumferential directions. Methods In this prospective study, 2-dimensional echocardiography (2DE) images of the LV were obtained in 52 subjects which included 32 patients (23 ± 8yrs, 16 male) with homozygous sickle cell anemia (SCA) in sickle cell crisis and 20 healthy controls (23 ± 5 yrs, 11 male) using apical 4-chamber and parasternal short-axis at the basal, mid, and apical levels. Of these 32 patients, 2DE was performed again in 18 patients in follow up (8 months ± 5 days). Longitudinal, circumferential and radial strains (LS, CS and RS respectively) were quantified and compared in an 18-segment model using a novel speckle tracking system (2D Cardiac Performance Analysis, TomTec Imaging System, Munich, Germany). Results There was no significant difference in LV ejection fraction between both the groups (59.32 ± 12.6 vs. 52.3 ± 7.9; p-value > 0.05). In comparison with normal controls and follow up of sickle cell patients, peak LS was significantly attenuated in the subendocardial and subepicardial regions during sickle cell crisis (p < 0.05). However, a significant reduction in circumferential strain was evident only in subepicardial region (p < 0.001). Also patients in sickle cell crisis showed significantly higher radial strain parameters than controls (p < 0.001). Conclusion Patients with SCA presenting in sickle cell crisis have reduced longitudinal shortening. LV myocardial performance remains unaltered due to relatively preserved circumferential shortening and increased radial thickening. PMID:23253406
Sengupta, Shantanu P; Jaju, Rahul; Nugurwar, Abhijeet; Caracciolo, Giuseppe; Sengupta, Partho P
2012-01-01
The status of left ventricle in sickle cell anemia presenting in sickle crisis and follow up has been minimally studied in past. To determine the left ventricular (LV) myocardial performance in these patients, we performed the study to assess two dimensional strains imaging which allowed a rapid and an accurate analysis of global and regional LV myocardial performance in longitudinal, radial, and circumferential directions. In this prospective study, 2-dimensional echocardiography (2DE) images of the LV were obtained in 52 subjects which included 32 patients (23 ± 8yrs, 16 male) with homozygous sickle cell anemia (SCA) in sickle cell crisis and 20 healthy controls (23 ± 5 yrs, 11 male) using apical 4-chamber and parasternal short-axis at the basal, mid, and apical levels. Of these 32 patients, 2DE was performed again in 18 patients in follow up (8 months ± 5 days). Longitudinal, circumferential and radial strains (LS, CS and RS respectively) were quantified and compared in an 18-segment model using a novel speckle tracking system (2D Cardiac Performance Analysis, TomTec Imaging System, Munich, Germany). There was no significant difference in LV ejection fraction between both the groups (59.32 ± 12.6 vs. 52.3 ± 7.9; p-value > 0.05). In comparison with normal controls and follow up of sickle cell patients, peak LS was significantly attenuated in the subendocardial and subepicardial regions during sickle cell crisis (p < 0.05). However, a significant reduction in circumferential strain was evident only in subepicardial region (p < 0.001). Also patients in sickle cell crisis showed significantly higher radial strain parameters than controls (p < 0.001). Patients with SCA presenting in sickle cell crisis have reduced longitudinal shortening. LV myocardial performance remains unaltered due to relatively preserved circumferential shortening and increased radial thickening. Copyright © 2012 Cardiological Society of India. Published by Elsevier B.V. All rights
Mutations in Either TUBB or MAPRE2 Cause Circumferential Skin Creases Kunze Type
Isrie, Mala; Breuss, Martin; Tian, Guoling; Hansen, Andi Harley; Cristofoli, Francesca; Morandell, Jasmin; Kupchinsky, Zachari A.; Sifrim, Alejandro; Rodriguez-Rodriguez, Celia Maria; Dapena, Elena Porta; Doonanco, Kurston; Leonard, Norma; Tinsa, Faten; Moortgat, Stéphanie; Ulucan, Hakan; Koparir, Erkan; Karaca, Ender; Katsanis, Nicholas; Marton, Valeria; Vermeesch, Joris Robert; Davis, Erica E.; Cowan, Nicholas J.; Keays, David Anthony; Van Esch, Hilde
2015-01-01
Circumferential skin creases Kunze type (CSC-KT) is a specific congenital entity with an unknown genetic cause. The disease phenotype comprises characteristic circumferential skin creases accompanied by intellectual disability, a cleft palate, short stature, and dysmorphic features. Here, we report that mutations in either MAPRE2 or TUBB underlie the genetic origin of this syndrome. MAPRE2 encodes a member of the microtubule end-binding family of proteins that bind to the guanosine triphosphate cap at growing microtubule plus ends, and TUBB encodes a β-tubulin isotype that is expressed abundantly in the developing brain. Functional analyses of the TUBB mutants show multiple defects in the chaperone-dependent tubulin heterodimer folding and assembly pathway that leads to a compromised yield of native heterodimers. The TUBB mutations also have an impact on microtubule dynamics. For MAPRE2, we show that the mutations result in enhanced MAPRE2 binding to microtubules, implying an increased dwell time at microtubule plus ends. Further, in vivo analysis of MAPRE2 mutations in a zebrafish model of craniofacial development shows that the variants most likely perturb the patterning of branchial arches, either through excessive activity (under a recessive paradigm) or through haploinsufficiency (dominant de novo paradigm). Taken together, our data add CSC-KT to the growing list of tubulinopathies and highlight how multiple inheritance paradigms can affect dosage-sensitive biological systems so as to result in the same clinical defect. PMID:26637975
Circumferentially oversewn inverted stapled anastomosis.
Karam, Charbel; Lord, Sally; Gett, Rohan; Meagher, Alan P
2018-04-01
Leak rates of over 5% following anastomoses between the ileum and colon continue to be reported in large series and are associated with substantial morbidity and with mortality rates of 10-20%. In 1994, we began performing circumferentially oversewn inverted stapled anastomoses in patients undergoing ileo-colic anastomoses or ileostomy closure. It has become increasingly apparent that this method is associated with a low risk of leakage, which we should report. The anastomotic technique described was used in all patients undergoing ileo-colic anastomosis or closure of ileostomy by surgeon 1 (1994-2015) and in all ileo-colic anastomoses by surgeon 2 (2007-2015). All patients had a widely patent anastomosis constructed by two firings of a linear cutting stapler, as previously described. Additionally, the entire staple line was carefully oversewn with interrupted, inverting 4/0 polydioxanone sutures. Anastomotic leak was defined as a patient requiring re-operation or radiological drainage. One thousand and twelve patients underwent ileo-colic anastomosis and 685 patients underwent closure of ileostomy by surgeon 1, and 165 patients underwent ileo-colic anastomosis by surgeon 2. None of the 1862 patients required re-operation or radiological drainage for a leak (event rate 0%, 95% confidence interval 0-0.2%). However, there were three possible contained leaks treated successfully conservatively. The time taken to perform the actual anastomosis was measured in the last 30 ileo-colic resections. The median time was 42 min. While this method may well be too slow to gain widespread adoption, we hope this report encourages increased research into finding techniques with similar low leak rates. © 2016 Royal Australasian College of Surgeons.
Transient thermal stress problem for a circumferentially cracked hollow cylinder
NASA Technical Reports Server (NTRS)
Nied, H. F.; Erdogan, F.
1983-01-01
The paper is concerned with the transient thermal stress problem for a long hollow circular cylinder containing an internal axisymmetric circumferential edge crack that is suddenly cooled from inside. It is assumed that the transient thermal stress problem is quasi-static, i.e., the inertial effects are negligible. Also, all thermoelastic coupling effects and the possible temperature dependence of the thermoelastic constants are neglected. The problem is considered in two parts. The first part is the evaluation of transient thermal stresses in an uncracked cylinder; the second part is the isothermal perturbation problem for the cracked cylinder in which the crack surface tractions, equal and opposite to the thermal stresses obtained from the first problem, are the only external loads. The superposition of the two solutions gives results for the cracked cylinder.
Ferferieva, V; Van den Bergh, A; Claus, P; Jasaityte, R; La Gerche, A; Rademakers, F; Herijgers, P; D'hooge, J
2013-08-01
This study was designed in order to compare the strain and strain rate deformation parameters assessed by speckle tracking imaging (STI) with those of tissue Doppler imaging (TDI) and conductance catheter measurements in chronic murine models of left ventricular (LV) dysfunction. Twenty-four male C57BL/6J mice were assigned to wild-type (n = 8), myocardial infarction (n = 8) and transaortic constriction (n = 8) groups. Echocardiographic and conductance measurements were simultaneously performed at rest and during dobutamine infusion (5 µg/kg/min) in all animals 10 weeks post-surgery. The LV circumferential strain (Scirc) and the strain rate (SRcirc) were derived from grey scale and tissue Doppler data at frame rates of 224 and 375 Hz, respectively. Scirc and SRcirc by TDI/STI correlated well with the preload recruitable stroke work (PRSW) (r = -0.64 and -0.71 for TDI; r = -0.46 and -0.50 for STI, P < 0.05). Both modalities showed a good agreement with respect to Scirc and SRcirc (r = 0.60 and r = 0.63, P < 0.05). During stress, however, TDI-estimated Scirc and SRcirc values were predominantly higher than those measured by STI (P < 0.05). The similarity of Scirc and SRcirc measurements with respect to the STI/TDI data was examined by the Bland-Altman analysis. In mice, the STI- and TDI-derived strain and strain rate deformation parameters relate closely to intrinsic myocardial function. At low heart rate-to-frame rate ratios (HR/FR), both STI and TDI are equally acceptable for assessing the LV function non-invasively in these animals. At HR/FR (e.g. dobutamine challenge), however, these methods cannot be used interchangeably as STI underestimates S and SR at high values.
Status of the steam generator tube circumferential ODSCC degradation experienced at the Doel 4 plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roussel, G.
1997-02-01
Since the 1991 outage, the Doel Unit 4 nuclear power plant is known to be affected by circumferential outside diameter intergranular stress corrosion cracking at the hot leg tube expansion transition. Extensive non destructive examination inspections have shown the number of tubes affected by this problem as well as the size of the cracks to have been increasing for the three cycles up to 1993. As a result of the high percentage of tubes found non acceptable for continued service after the 1993 in-service inspection, about 1,700 mechanical sleeves were installed in the steam generators. During the 1994 outage, allmore » the tubes sleeved during the 1993 outage were considered as potentially cracked to some extent at the upper hydraulic transition and were therefore not acceptable for continued service. They were subsequently repaired by laser welding. Furthermore all the tubes not sleeved during the 1993 outage were considered as not acceptable for continued service and were repaired by installing laser welded sleeves. During the 1995 outage, some unexpected degradation phenomena were evidenced in the sleeved tubes. This paper summarizes the status of the circumferential ODSCC experienced in the SG tubes of the Doel 4 plant as well as the other connected degradation phenomena.« less
Dynamic strains for earthquake source characterization
Barbour, Andrew J.; Crowell, Brendan W
2017-01-01
Strainmeters measure elastodynamic deformation associated with earthquakes over a broad frequency band, with detection characteristics that complement traditional instrumentation, but they are commonly used to study slow transient deformation along active faults and at subduction zones, for example. Here, we analyze dynamic strains at Plate Boundary Observatory (PBO) borehole strainmeters (BSM) associated with 146 local and regional earthquakes from 2004–2014, with magnitudes from M 4.5 to 7.2. We find that peak values in seismic strain can be predicted from a general regression against distance and magnitude, with improvements in accuracy gained by accounting for biases associated with site–station effects and source–path effects, the latter exhibiting the strongest influence on the regression coefficients. To account for the influence of these biases in a general way, we include crustal‐type classifications from the CRUST1.0 global velocity model, which demonstrates that high‐frequency strain data from the PBO BSM network carry information on crustal structure and fault mechanics: earthquakes nucleating offshore on the Blanco fracture zone, for example, generate consistently lower dynamic strains than earthquakes around the Sierra Nevada microplate and in the Salton trough. Finally, we test our dynamic strain prediction equations on the 2011 M 9 Tohoku‐Oki earthquake, specifically continuous strain records derived from triangulation of 137 high‐rate Global Navigation Satellite System Earth Observation Network stations in Japan. Moment magnitudes inferred from these data and the strain model are in agreement when Global Positioning System subnetworks are unaffected by spatial aliasing.
Trincado, Claudia; Molina, Víctor; Urcelay, Gonzalo; Dellepiane, Paulina
2018-02-01
The echocardiographic evaluation of patients after heart transplantation is a useful tool. However, it is still necessary to define an optimal follow-up protocol. To describe the results of the application of a functional echocardiographic protocol in patients being followed after pediatric heart transplantation. Alls patients being followed at our institution after pediatric heart transplantation underwent an echocardiographic examination with a functional protocol that included global longitudinal strain. Contemporaneous endomyocardial biopsy results and hemodynamic data were recorded. 9 patients were evaluated with our echocardiographic functional protocol. Of these patients, only 1 showed systolic left ventricular dysfunction according to classic parameters. However, almost all patients had an abnormal global longitudinal strain. Right ventricular systolic dysfunction was observed in all patients. No epidodes of moderate to severe rejectiom were recorded. No correlation was observed between these parameters and pulmonary artery pressure. Subclinical biventricular systolic dysfunction was observed in the majority of the patients in this study. No association with rejection episodes or pulmonary hypertension was observed, which may be related to the absence of moderate or severe rejection episodes during the study period, and to the small sample size. Long term follow-up of these patients may better define the clinical relevance of our findings.
Lima, Marcio Silva Miguel; Villarraga, Hector R; Abduch, Maria Cristina Donadio; Lima, Marta Fernandes; Cruz, Cecilia Beatriz Bittencourt Viana; Sbano, João Cesar Nunes; Voos, Mariana Callil; Mathias, Wilson; Tsutsui, Jeane Mike
2017-07-01
Estimative of left ventricular ejection fraction (LVEF) is a major indication for echocardiography. Speckle tracking echocardiography (STE) allows analysis of LV contraction mechanics which includes global longitudinal strain (GLS) and twist/torsion, both the most widely used. Direct comparison of correlations between these novel parameters and LVEF has never been done before. This study aims to check which one has the highest correlation with LVEF. Patients with normal LVEF (> 0,55) and systolic dysfunction (LVEF <0,55) were prospectively enrolled, and underwent echocardiogram with STE analysis. Correlation of variables was performed by linear regression analysis. In addition, correlation among levels of LV systolic impairment was also tested. A total of 131 patients were included (mean age, 46 ± 14y; 43%, men). LVEF and GLS showed a strong correlation (r = 0.95; r2 = 0.89; p < 0.001), more evident in groups with LV systolic dysfunction than those with preserved LVEF. Good correlation was also found with global longitudinal strain rate (r = 0.85; r2 = 0.73; p < 0.001). Comparing to GLS, correlation of LVEF and torsional mechanics was weaker: twist (r = 0.78; r2 = 0.60; p < 0.001); torsion (r = 0.75; r2 = 0.56; p < 0.001). GLS of the left ventricle have highly strong positive correlation with the classical parameter of ejection fraction, especially in cases with LV systolic impairment. Longitudinal strain rate also demonstrated a good correlation. GLS increments analysis of LV systolic function. On the other hand, although being a cornerstone of LV mechanics, twist and torsion have a weaker correlation with LV ejection, comparing to GLS. A estimativa da fração de ejeção do ventrículo esquerdo (FEVE) é uma das pincipais indicações para a ecocardiografia. Speckle tracking (ST) permite a análise da mecânica de contração do VE que inclui a deformação (strain) longitudinal global (SLG) e o twist / torção, sendo ambos os mais utilizados. A compara
Batagini, Nayara Cioffi; Ventura, Carlos Augusto Pinto; Raghavan, Madhavan L; Chammas, Maria Cristina; Tachibana, Adriano; da Silva, Erasmo Simão
2016-06-01
The objective was to demonstrate the ability of ultrasound (US) with 3D properties to evaluate volumetry and biomechanical parameters of the aorta in patients with and without abdominal aortic aneurysm (AAA). Thirty-one patients with normal aortas (group 1), 46 patients with AAA measuring 3.0-5.5 cm (group 2) and 31 patients with AAA ⩾ 5.5 cm (group 3) underwent a 2D/3D-US examination of the infra-renal aorta, and the images were post-processed prior to being analyzed. In the maximum diameter, the global circumferential strain and the global maximum rotation assessed by 2D speckle-tracking algorithms were compared among the three groups. The volumetry data obtained using 3D-US from 40 AAA patients were compared with the volumetry data obtained by a contemporary computed tomography (CT) scan. The median global circumferential strain was 2.0% (interquartile range (IR): 1.0-3.0), 1.0% (IR: 1.0-2.0) and 1.0% (IR: 1.0-1.75) in groups 1, 2 and 3, respectively (p < 0.001). The median global maximum rotation decreased progressively from group 1 to group 3 (1.38º (IR: 0.77-2.13), 0.80º (IR: 0.57-1.0) and 0.50º (IR: 0.31-0.75), p < 0.001). AAA volume estimations by 3D-US correlated well with CT (R(2) = 0.76). In conclusion, US with 3D properties is non-invasive and has the potential to evaluate volumetry and biomechanical characteristics of AAA. © The Author(s) 2016.
Manson, Abigail L.; Cohen, Keira A.; Abeel, Thomas; Desjardins, Christopher A.; Armstrong, Derek T.; Barry, Clifton E.; Brand, Jeannette; Chapman, Sinéad B.; Cho, Sang-Nae; Gabrielian, Andrei; Gomez, James; Jodals, Andreea M.; Joloba, Moses; Jureen, Pontus; Lee, Jong Seok; Malinga, Lesibana; Maiga, Mamoudou; Nordenberg, Dale; Noroc, Ecaterina; Romancenco, Elena; Salazar, Alex; Ssengooba, Willy; Velayati, A. A.; Winglee, Kathryn; Zalutskaya, Aksana; Via, Laura E.; Cassell, Gail H.; Dorman, Susan E.; Ellner, Jerrold; Farnia, Parissa; Galagan, James E.; Rosenthal, Alex; Crudu, Valeriu; Homorodean, Daniela; Hsueh, Po-Ren; Narayanan, Sujatha; Pym, Alexander S.; Skrahina, Alena; Swaminathan, Soumya; Van der Walt, Martie; Alland, David; Bishai, William R.; Cohen, Ted; Hoffner, Sven; Birren, Bruce W.; Earl, Ashlee M.
2017-01-01
Multidrug-resistant tuberculosis (MDR-TB), caused by drug resistant strains of Mycobacterium tuberculosis, is an increasingly serious problem worldwide. In this study, we examined a dataset of 5,310 M. tuberculosis whole genome sequences from five continents. Despite great diversity with respect to geographic point of isolation, genetic background and drug resistance, patterns of drug resistance emergence were conserved globally. We have identified harbinger mutations that often precede MDR. In particular, the katG S315T mutation, conferring resistance to isoniazid, overwhelmingly arose before rifampicin resistance across all lineages, geographic regions, and time periods. Molecular diagnostics that include markers for rifampicin resistance alone will be insufficient to identify pre-MDR strains. Incorporating knowledge of pre-MDR polymorphisms, particularly katG S315, into molecular diagnostics will enable targeted treatment of patients with pre-MDR-TB to prevent further development of MDR-TB. PMID:28092681
Cruz-Perez, Benjamin; Tang, Junhua; Morris, Hugh J.; Palko, Joel R.; Pan, Xueliang; Hart, Richard T.; Liu, Jun
2014-01-01
This study aimed to characterize the mechanical responses of the sclera, the white outer coat of the eye, under equal-biaxial loading with unrestricted shear. An ultrasound speckle tracking technique was used to measure tissue deformation through sample thickness, expanding the capabilities of surface strain techniques. Eight porcine scleral samples were tested within 72 hours postmortem. High resolution ultrasound scans of scleral cross-sections along the two loading axes were acquired at 25 consecutive biaxial load levels. An additional repeat of the biaxial loading cycle was performed to measure a third normal strain emulating a strain gauge rosette for calculating the in-plane shear. The repeatability of the strain measurements during identical biaxial ramps was evaluated. A correlation-based ultrasound speckle tracking algorithm was used to compute the displacement field and determine the distributive strains in the sample cross-sections. A Fung type constitutive model including a shear term was used to determine the material constants of each individual specimen by fitting the model parameters to the experimental stress-strain data. A non-linear stress-strain response was observed in all samples. The meridian direction had significantly larger strains than the circumferential direction during equal-biaxial loadings (P’s<0.05). The stiffness along the two directions were also significantly different (P=0.02) but highly correlated (R2=0.8). These results showed that the mechanical properties of the porcine sclera were nonlinear and anisotropic under biaxial loading. This work has also demonstrated the feasibility of using ultrasound speckle tracking for strain measurements during mechanical testing. PMID:24438767
Takamizawa, Keiichi; Nakayama, Yasuhide
2013-11-01
It is well known that arteries are subject to residual stress. In earlier studies, the residual stress in the arterial ring relieved by a radial cut was considered in stress analysis. However, it has been found that axial strips sectioned from arteries also curled into arcs, showing that the axial residual stresses were relieved from the arterial walls. The combined relief of circumferential and axial residual stresses must be considered to accurately analyze stress and strain distributions under physiological loading conditions. In the present study, a mathematical model of a stress-free configuration of artery was proposed using Riemannian geometry. Stress analysis for arterial walls under unloaded and physiologically loaded conditions was performed using exponential strain energy functions for porcine and human common carotid arteries. In the porcine artery, the circumferential stress distribution under physiological loading became uniform compared with that without axial residual strain, whereas a gradient of axial stress distribution increased through the wall thickness. This behavior showed almost the same pattern that was observed in a recent study in which approximate analysis accounting for circumferential and axial residual strains was performed, whereas the circumferential and axial stresses increased from the inner surface to the outer surface under a physiological condition in the human common carotid artery of a two-layer model based on data of other recent studies. In both analyses, Riemannian geometry was appropriate to define the stress-free configurations of the arterial walls with both circumferential and axial residual strains.
NASA Technical Reports Server (NTRS)
Dittrich, R. T.
1972-01-01
Water flow tests with circumferential inlet and outlet manifolds were conducted to determine factors affecting fluid distribution and pressure losses. Various orifice sizes and manifold geometries were tested over a range of flow velocities. With inlet manifolds, flow distribution was related directly to orifice discharge coefficients. A correlation indicated that nonuniform distribution resulted when the velocity head ratio at the orifice was not in the range of constant discharge coefficient. With outlet manifolds, nonuniform flow was related to static pressure variations along the manifold. Outlet manifolds had appreciably greater pressure losses than comparable inlet manifolds.
Growth behavior of surface cracks in the circumferential plane of solid and hollow cylinders
NASA Technical Reports Server (NTRS)
Forman, R. G.; Shivakumar, V.
1986-01-01
Experiments were conducted to study the growth behavior of surface fatigue cracks in the circumferential plane of solid and hollow cylinders. In the solid cylinders, the fatigue cracks were found to have a circular arc crack front with specific upper and lower limits to the arc radius. In the hollow cylinders, the fatigue cracks were found to agree accurately with the shape of a transformed semiellipse. A modification to the usual nondimensionalization expression used for surface flaws in flat plates was found to give correct trends for the hollow cylinder problem.
NASA Technical Reports Server (NTRS)
Fuller, C. R.
1984-01-01
Sound propagation in infinite, semiinfinite, and finite circular ducts with circumferentially varying wall admittances is investigated analytically. The infinite case is considered, and an example demonstrates the effects of wall-admittance distribution on dispersion characteristics and mode shapes. An exact solution is obtained for the semiinfinite case, a circular duct with a flanged opening: sidelobe suppression and circumferential-mode energy scattering leading to radiated-field asymmetry are found. A finite duct system with specified hard-walled pressure sources is examined in detail, evaluating reflection coefficients, transmission losses, and radiated-field directivity. Graphs and diagrams are provided, and the implications of the results obtained for the design of aircraft-turbofan inlet liners are discussed.
Transient thermal stress problem for a circumferentially cracked hollow cylinder
NASA Technical Reports Server (NTRS)
Nied, H. F.; Erdogan, F.
1982-01-01
The transient thermal stress problem for a hollow elasticity cylinder containing an internal circumferential edge crack is considered. It is assumed that the problem is axisymmetric with regard to the crack geometry and the loading, and that the inertia effects are negligible. The problem is solved for a cylinder which is suddenly cooled from inside. First the transient temperature and stress distributions in an uncracked cylinder are calculated. By using the equal and opposite of this thermal stress as the crack surface traction in the isothermal cylinder the crack problem is then solved and the stress intensity factor is calculated. The numerical results are obtained as a function of the Fourier number tD/b(2) representing the time for various inner-to-outer radius ratios and relative crack depths, where D and b are respectively the coefficient of diffusivity and the outer radius of the cylinder.
NASA Technical Reports Server (NTRS)
Young, Richard D.; Rose, Cheryl A.; Starnes, James H., Jr.
2000-01-01
Results of a geometrically nonlinear finite element parametric study to determine curvature correction factors or bulging factors that account for increased stresses due to curvature for longitudinal and circumferential cracks in unstiffened pressurized cylindrical shells are presented. Geometric parameters varied in the study include the shell radius, the shell wall thickness, and the crack length. The major results are presented in the form of contour plots of the bulging factor as a function of two nondimensional parameters: the shell curvature parameter, lambda, which is a function of the shell geometry, Poisson's ratio, and the crack length; and a loading parameter, eta, which is a function of the shell geometry, material properties, and the applied internal pressure. These plots identify the ranges of the shell curvature and loading parameters for which the effects of geometric nonlinearity are significant. Simple empirical expressions for the bulging factor are then derived from the numerical results and shown to predict accurately the nonlinear response of shells with longitudinal and circumferential cracks. The numerical results are also compared with analytical solutions based on linear shallow shell theory for thin shells, and with some other semi-empirical solutions from the literature, and limitations on the use of these other expressions are suggested.
Wu, Linhuan; McCluskey, Kevin; Desmeth, Philippe; Liu, Shuangjiang; Hideaki, Sugawara; Yin, Ye; Moriya, Ohkuma; Itoh, Takashi; Kim, Cha Young; Lee, Jung-Sook; Zhou, Yuguang; Kawasaki, Hiroko; Hazbón, Manzour Hernando; Robert, Vincent; Boekhout, Teun; Lima, Nelson; Evtushenko, Lyudmila; Boundy-Mills, Kyria; Bunk, Boyke; Moore, Edward R B; Eurwilaichitr, Lily; Ingsriswang, Supawadee; Shah, Heena; Yao, Su; Jin, Tao; Huang, Jinqun; Shi, Wenyu; Sun, Qinglan; Fan, Guomei; Li, Wei; Li, Xian; Kurtböke, Ipek; Ma, Juncai
2018-05-01
Genomic information is essential for taxonomic, phylogenetic, and functional studies to comprehensively decipher the characteristics of microorganisms, to explore microbiomes through metagenomics, and to answer fundamental questions of nature and human life. However, large gaps remain in the available genomic sequencing information published for bacterial and archaeal species, and the gaps are even larger for fungal type strains. The Global Catalogue of Microorganisms (GCM) leads an internationally coordinated effort to sequence type strains and close gaps in the genomic maps of microorganisms. Hence, the GCM aims to promote research by deep-mining genomic data.
Vallefuoco, Rosario; Pignon, Charly; Furst, Anna; Personne, Lauriane; Courreau, Jean-Francois; Moissonnier, Pierre
2013-06-01
A free-ranging adult female hedgehog (Erinaceus europaeus) was presented injured, presumably from vehicular trauma. Clinical and radiographic examination under general anesthesia revealed a lateral elbow luxation. Closed reduction was unsuccessful, so a surgical approach with circumferential suture prostheses was used to stabilize the elbow. Neither perioperative nor postoperative complications were recorded. The hedgehog regained good range of motion of the elbow and was fully able to run and to roll into a ball.
Choy, Jenny Susana; Dang, Quang; Molloi, Sabee; Kassab, Ghassan S
2006-04-01
The pressure-induced remodeling of coronary veins is important in coronary venous retroperfusion. Our hypothesis is that the response of the large coronary veins to pressure overload will depend on the degree of myocardial support. Eleven normal Yorkshire swine from either sex, weighing 31-39 kg, were studied. Five pigs underwent ligation of the left anterior descending (LAD) vein, and six served as sham-operated controls. The ligation of the coronary vein caused an increase in pressure intermediate to arterial and venous values. After 2 wk of ligation, the animals were euthanized and the coronary vessels were perfusion-fixed with glutaraldehyde. The LAD vein was sectioned, and detailed morphometric measurements were made along its length from the point of ligation near the base down to the apex of the heart. The structural remodeling of the vein was circumferentially nonuniform because the vein is partially embedded in the myocardium; it was also axially nonuniform because it is tethered to the myocardium to different degrees along its axial length. The wall area was significantly larger in the experimental group, whereas luminal area in the proximal LAD vein was significantly smaller in the same group compared with sham-operated controls. The wall thickness-to-radius ratio was also significantly larger in the experimental group in proportion to the increase in pressure. The major conclusion of this study is that the response of the vein depends on the local wall stress, which is, in part, determined by the surrounding tissue. Furthermore, the geometric remodeling of the coronary vein restores the circumferential stress to the homeostatic value.
Soil sampling device with latch assembly having a variable circumferential shape
Meyer, Robert D.
1996-01-01
The invention relates to an improved sampler which can be operated in any orientation. The design features a positive gripping of the operating rod in a manner to reduce point loads so as to reduce any possibility of jamming of the rod on a retraction stroke until such time as it is positively retained in the fully withdrawn position. In the preferred embodiment, a pair of mating cylindrical latch pieces, held together by a circumferential spring, are used for positive actuation. The inner rod has an angular cut-out which provides the base for the latch when aligned with the latch. A release fixture can be used to free the latch from the cone rod after actuation. The latches are formed in such a manner as they may support themselves within the housing of the sampler until they engage the operating rod.
Aerial ultrasound source with a circular vibrating plate attached to a rigid circumferential wall
NASA Astrophysics Data System (ADS)
Kuratomi, Ryo; Asami, Takuya; Miura, Hikaru
2018-07-01
We fabricate a transverse vibrating plate attached to a rigid wall integrated at the circumference of a circular vibrating plate that allows a strong sound wave field to be formed in the area encoded by the vibrating plate and rigid wall by installing a wall such as a reflective plate on the rigid wall. The design method for the circular vibrating plate attached to a rigid circumferential wall is investigated. A method of forming a strong standing wave field in an enclosed area constructed with a vibrating plate, cylindrical reflective plate, and parallel reflective plate is developed.
Hsiao, Amy Y; Okitsu, Teru; Onoe, Hiroaki; Kiyosawa, Mahiro; Teramae, Hiroki; Iwanaga, Shintaroh; Kazama, Tomohiko; Matsumoto, Taro; Takeuchi, Shoji
2015-01-01
The proper functioning of many organs and tissues containing smooth muscles greatly depends on the intricate organization of the smooth muscle cells oriented in appropriate directions. Consequently controlling the cellular orientation in three-dimensional (3D) cellular constructs is an important issue in engineering tissues of smooth muscles. However, the ability to precisely control the cellular orientation at the microscale cannot be achieved by various commonly used 3D tissue engineering building blocks such as spheroids. This paper presents the formation of coiled spring-shaped 3D cellular constructs containing circumferentially oriented smooth muscle-like cells differentiated from dedifferentiated fat (DFAT) cells. By using the cell fiber technology, DFAT cells suspended in a mixture of extracellular proteins possessing an optimized stiffness were encapsulated in the core region of alginate shell microfibers and uniformly aligned to the longitudinal direction. Upon differentiation induction to the smooth muscle lineage, DFAT cell fibers self-assembled to coiled spring structures where the cells became circumferentially oriented. By changing the initial core-shell microfiber diameter, we demonstrated that the spring pitch and diameter could be controlled. 21 days after differentiation induction, the cell fibers contained high percentages of ASMA-positive and calponin-positive cells. Our technology to create these smooth muscle-like spring constructs enabled precise control of cellular alignment and orientation in 3D. These constructs can further serve as tissue engineering building blocks for larger organs and cellular implants used in clinical treatments.
Hsiao, Amy Y.; Okitsu, Teru; Onoe, Hiroaki; Kiyosawa, Mahiro; Teramae, Hiroki; Iwanaga, Shintaroh; Kazama, Tomohiko; Matsumoto, Taro; Takeuchi, Shoji
2015-01-01
The proper functioning of many organs and tissues containing smooth muscles greatly depends on the intricate organization of the smooth muscle cells oriented in appropriate directions. Consequently controlling the cellular orientation in three-dimensional (3D) cellular constructs is an important issue in engineering tissues of smooth muscles. However, the ability to precisely control the cellular orientation at the microscale cannot be achieved by various commonly used 3D tissue engineering building blocks such as spheroids. This paper presents the formation of coiled spring-shaped 3D cellular constructs containing circumferentially oriented smooth muscle-like cells differentiated from dedifferentiated fat (DFAT) cells. By using the cell fiber technology, DFAT cells suspended in a mixture of extracellular proteins possessing an optimized stiffness were encapsulated in the core region of alginate shell microfibers and uniformly aligned to the longitudinal direction. Upon differentiation induction to the smooth muscle lineage, DFAT cell fibers self-assembled to coiled spring structures where the cells became circumferentially oriented. By changing the initial core-shell microfiber diameter, we demonstrated that the spring pitch and diameter could be controlled. 21 days after differentiation induction, the cell fibers contained high percentages of ASMA-positive and calponin-positive cells. Our technology to create these smooth muscle-like spring constructs enabled precise control of cellular alignment and orientation in 3D. These constructs can further serve as tissue engineering building blocks for larger organs and cellular implants used in clinical treatments. PMID:25734774
NASA Technical Reports Server (NTRS)
Bozak, Richard F.; Hughes, Christopher E.; Buckley, James
2013-01-01
While liners have been utilized throughout turbofan ducts to attenuate fan noise, additional attenuation is obtainable by placing an acoustic liner over-the-rotor. Previous experiments have shown significant fan performance losses when acoustic liners are installed over-the-rotor. The fan blades induce an oscillating flow in the acoustic liners which results in a performance loss near the blade tip. An over-the-rotor liner was designed with circumferential grooves between the fan blade tips and the acoustic liner to reduce the oscillating flow in the acoustic liner. An experiment was conducted in the W-8 Single-Stage Axial Compressor Facility at NASA Glenn Research Center on a 1.5 pressure ratio fan to evaluate the impact of this over-the-rotor treatment design on fan aerodynamic performance. The addition of a circumferentially grooved over-the-rotor design between the fan blades and the acoustic liner reduced the performance loss, in terms of fan adiabatic efficiency, to less than 1 percent which is within the repeatability of this experiment.
NASA Technical Reports Server (NTRS)
Bozak, Rick; Hughes, Christopher; Buckley, James
2013-01-01
While liners have been utilized throughout turbofan ducts to attenuate fan noise, additional attenuation is obtainable by placing an acoustic liner over-the-rotor. Previous experiments have shown significant fan performance losses when acoustic liners are installed over-the-rotor. The fan blades induce an oscillating flow in the acoustic liners which results in a performance loss near the blade tip. An over-the-rotor liner was designed with circumferential grooves between the fan blade tips and the acoustic liner to reduce the oscillating flow in the acoustic liner. An experiment was conducted in the W-8 Single-Stage Axial Compressor Facility at NASA Glenn Research Center on a 1.5 pressure ratio fan to evaluate the impact of this over-the-rotor treatment design on fan aerodynamic performance. The addition of a circumferentially grooved over-the-rotor design between the fan blades and the acoustic liner reduced the performance loss, in terms of fan adiabatic efficiency, to less than 1% which is within the repeatability of this experiment.
The degree of circumferential tumour involvement as a prognostic factor in oesophageal cancer.
Sillah, Karim; Pritchard, Susan A; Watkins, Gillian R; McShane, James; West, Catharine M; Page, Richard; Welch, Ian M
2009-08-01
Tumour length is an adverse prognostic factor in oesophageal cancer. However, the prognostic role of the degree of oesophageal circumference (DOC) involved by tumour with or without resection margin invasion is not clear. This work assessed the relationship between DOC involved by tumour, clinico-pathological variables and prognosis. The clinico-pathological details of 320 patients who underwent potentially curative oesophagogastrectomy for cancer between 1994 and 2007 were analysed. The DOC involved with tumour measured macroscopically on the resected specimen was classified as small (<2.5 cm, n = 115), large (> or = 2.5 cm, n = 144) or circumferential (i.e. involving the whole circumference, n = 61). Univariate and multivariate survival analyses were carried out. The DOC with tumour was higher in ulcerating tumours than stenosing or polypoidal types (p = 0.017). Tumour length, T-stage, neoadjuvant chemotherapy and vascular invasion were independently associated with DOC with tumour on multivariate analysis (p < 0.05 for all). DOC > or = 2.5 cm was an adverse prognostic factor in univariate analysis (p = 0.002) with a hazard ratio of 1.52 [95% CI 1.13-2.04] compared with those <2.5 cm. Circumferential tumours had a similar prognosis to tumours > or = 2.5 cm (p = 0.60). The prognostic significance of DOC with tumour was lost in multivariate analysis where the factors retaining independence were patient age, T-stage, lymph node metastasis, vascular invasion and positive resection margins. However, when patients were stratified by use of neoadjuvant chemotherapy (n = 121), the DOC with tumour retained prognostic significance on multivariate analysis in the 199 patients who did not undergo neoadjuvant chemotherapy (p = 0.04). The DOC with tumour appears to provide prognostic information in oesophageal cancer surgery, especially in patients who do not undergo preoperative chemotherapy.
NASA Astrophysics Data System (ADS)
Arkwright, J. W.; Blenman, N. G.; Underhill, I. D.; Maunder, S. A.; Spencer, N. J.; Costa, M.; Brooks, S. J.; Szczesniak, M. M.; Dinning, P. G.
2010-09-01
Diagnostic catheters based on fibre Bragg gratings (FBG's) are proving to be highly effective for measurement of the muscular activity associated with peristalsis in the human gut. The primary muscular contractions that generate peristalsis are circumferential in nature; however, it has long been known that there is also a component of longitudinal contractility present, acting in harmony with the circumferential component to improve the overall efficiency of material movement. To date, there have been relatively few reports on the measurement or inference of longitudinal contractions in humans and all have been limited to detection at a single location only. This is due to the lack of a viable recording technique suitable for real-time in-vivo measurement of this type of activity over extended lengths of the gut. We report the detection of longitudinal motion in lengths of excised mammalian colon using an FBG technique that should be viable for similar detection in humans. The longitudinal sensors have been combined with our previously reported FBG pressure sensing elements to form a composite catheter that allows the relative phase between the two components to be detected. The catheter output has been validated using digital video mapping in an ex-vivo animal preparation using lengths of rabbit ileum.
Navarini, Susanne; Bellsham-Revell, Hannah; Chubb, Henry; Gu, Haotian; Sinha, Manish D; Simpson, John M
2017-12-01
Systemic arterial hypertension predisposes children to cardiovascular risk in childhood and adult life. Despite extensive study of left ventricular (LV) hypertrophy, detailed 3-dimensional strain analysis of cardiac function in hypertensive children has not been reported. The aim of this study was to evaluate LV mechanics (strain, twist, and torsion) in young patients with hypertension compared with a healthy control group and assess factors associated with functional measurements. Sixty-three patients (26 hypertension and 37 normotensive) were enrolled (mean age, 14.3 and 11.4 years; 54% men and 41% men, respectively). All children underwent clinical evaluation and echocardiographic examination, including 3-dimensional strain. There was no difference in LV volumes and ejection fraction between the groups. Myocardial deformation was significantly reduced in those with hypertension compared with controls. For hypertensive and normotensive groups, respectively, global longitudinal strain was -15.1±2.3 versus -18.5±1.9 ( P <0.0001), global circumferential strain -15.2±3 versus -19.9±3.1 (<0.0001), global radial strain +44.0±11.3 versus 63.4±10.5 ( P <0.0001), and global 3-dimensional strain -26.1±3.8 versus -31.5±3.8 ( P <0.0001). Basal clockwise rotation, apical counterclockwise rotation, twist, and torsion were not significantly different. After multivariate regression analyses blood pressure, body mass index and LV mass maintained a significant relationship with measures of LV strain. Similar ventricular volumes and ejection fraction were observed in hypertensive and normotensive children, but children with hypertension had significantly lower strain indices. Whether reduced strain might predict future cardiovascular risk merits further longitudinal study. © 2017 American Heart Association, Inc.
Bardet, Lucie; Cimmino, Teresa; Buffet, Clémence; Michelle, Caroline; Rathored, Jaishriram; Tandina, Fatalmoudou; Lagier, Jean-Christophe; Khelaifia, Saber; Abrahão, Jônatas; Raoult, Didier; Rolain, Jean-Marc
2018-02-01
Culturomics is a new postgenomics field that explores the microbial diversity of the human gut coupled with taxono-genomic strategy. Culturomics, and the microbiome science more generally, are anticipated to transform global health diagnostics and inform the ways in which gut microbial diversity contributes to human health and disease, and by extension, to personalized medicine. Using culturomics, we report in this study the description of strain CB1 T ( = CSUR P1334 = DSM 29075), a new species isolated from a stool specimen from a 37-year-old Brazilian woman. This description includes phenotypic characteristics and complete genome sequence and annotation. Strain CB1 T is a gram-negative aerobic and motile bacillus, exhibits neither catalase nor oxidase activities, and presents a 98.3% 16S rRNA sequence similarity with Pseudomonas putida. The 4,723,534 bp long genome contains 4239 protein-coding genes and 74 RNA genes, including 15 rRNA genes (5 16S rRNA, 4 23S rRNA, and 6 5S rRNA) and 59 tRNA genes. Strain CB1 T was named Pseudomonas massiliensis sp. nov. and classified into the family Pseudomonadaceae. This study demonstrates the usefulness of microbial culturomics in exploration of human microbiota in diverse geographies and offers new promise for incorporating new omics technologies for innovation in diagnostic medicine and global health.
Soil sampling device with latch assembly having a variable circumferential shape
Meyer, R.D.
1996-12-24
The invention relates to an improved sampler which can be operated in any orientation. The design features a positive gripping of the operating rod in a manner to reduce point loads so as to reduce any possibility of jamming of the rod on a retraction stroke until such time as it is positively retained in the fully withdrawn position. In the preferred embodiment, a pair of mating cylindrical latch pieces, held together by a circumferential spring, are used for positive actuation. The inner rod has an angular cut-out which provides the base for the latch when aligned with the latch. A release fixture can be used to free the latch from the cone rod after actuation. The latches are formed in such a manner as they may support themselves within the housing of the sampler until they engage the operating rod. 11 figs.
Chen, Jing; Yang, Zhi-Gang; Xu, Hua-Yan; Shi, Ke; Guo, Ying-Kun
2018-02-15
To assess left ventricular myocardial deformation in patients with primary cardiac tumors. MRI was retrospectively performed in 61 patients, including 31 patients with primary cardiac tumors and 30 matched normal controls. Left ventricular strain and function parameters were then assessed by MRI-tissue tracking. Differences between the tumor group and controls, left and right heart tumor groups, left ventricular wall tumor and non-left ventricular wall tumor groups, and tumors with and without LV enlargement groups were assessed. Finally, the correlations among tumor diameter, myocardial strain, and LV function were analyzed. Left ventricular myocardial strain was milder for tumor group than for normal group. Peak circumferential strain (PCS) and its diastolic strain rate, longitudinal strains (PLS) and its diastolic strain rates, and peak radial systolic and diastolic velocities of the right heart tumor group were lower than those of the left heart tumor group (all p<0.050), but the peak radial systolic strain rate of the former was higher than that of the latter (p=0.017). The corresponding strains were lower in the left ventricular wall tumor groups than in the non-left ventricular wall tumor group (p<0.050). Peak radial systolic velocities were generally higher for tumors with LV enlargement than for tumors without LV enlargement (p<0.050). Peak radial strain, PCS, and PLS showed important correlations with the left ventricular ejection fraction (all p<0.050). MRI-tissue tracking is capable of quantitatively assessing left ventricular myocardial strain to reveal sub-clinical abnormalities of myocardial contractile function. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Yos, William T. (Inventor); Cantrell, John H., Jr. (Inventor)
2004-01-01
A method and apparatus for measuring changes in intracranial pressure (ICP) utilizing the variation of the surface wave propagation parameters of the patient's skull to determine the change in ICP. In one embodiment, the method comprises the steps of transmitting an ultrasonic bulk compressional wave onto the surface of the skull at a predetermined angle with respect to the skull so as to produce a surface wave, receiving the surface wave at an angle with respect tn the skull which is substantially the same as the predetermined angle and at a location that is a predetermined distance from where the ultrasonic bulk compressional wave was transmitted upon the skull, determining the retardation or advancement in phase of the received surface wave with respect to a reference phase, and processing the determined retardation or advancement in phase to determine circumferential expansion or contraction of the skull and utilizing the determined circumferential change to determine the change in intracranial pressure.
Felekos, Ioannis; Aggeli, Constantina; Gialafos, Elias; Kouranos, Vasileios; Rapti, Aggeliki; Sfikakis, Petros; Koulouris, Nikolaos; Tousoulis, Dimitris
2018-06-01
Global longitudinal strain (GLS) is increasingly accepted as a predictor of mortality in various clinical settings. This study tested the hypothesis that GLS is associated with increased event rate in patients with extracardiac sarcoidosis, who have no overt symptoms of cardiovascular disease and preserved ejection fraction (EF). We retrospectively studied 117 patients with extracardiac sarcoidosis and 45 age- and sex-matched controls, who underwent comprehensive echocardiographic study, while GLS was measured by an offline speckle tracking algorithm. Patients who had signs and symptoms of cardiovascular disease at the time of the examination were excluded from the study. Patients were followed for an average of 57.1 months. Primary endpoint was defined as a composite endpoint of heart failure-related hospitalizations, need for device therapy, arrhythmias, and all-cause mortality. The age of patients was 42 ± 6 years old (43 men). Events were recorded in 10 patients (8.5%). Tissue Doppler revealed E/Em 7.9 ± 3.5, while EF was 54.2 ± 3.5%. Global longitudinal strain was 14.4 ± 3%, and a cutoff value ≤-13.6% for GLS was considered more associated with adverse outcomes (AUC 0.84). After adjustment for multiple potential confounders (age, gender, hypertension, diabetes, E/Em, and EF), GLS remained strongly associated with adverse outcomes (HR 0.8, 0.63 to 0.98 95% C.I, P = .04). In conclusion, among patients with extracardiac sarcoidosis and no symptoms of cardiovascular disease, even when EF is preserved, GLS seems to be strongly associated with adverse future events. © 2018 Wiley Periodicals, Inc.
Main, Russell P
2007-01-01
Vertebrate long bone form, at both the gross and the microstructural level, is the result of many interrelated influences. One factor that is considered to have a significant effect on bone form is the mechanical environment experienced by the bone during growth. The work presented here examines the possible relationships between in vivo bone strains, bone geometry and histomorphology in the radii of three age/size groups of domestic goats. In vivo bone strain data were collected from the radii of galloping goats, and the regional cortical distribution of peak axial strain magnitudes, radial and circumferential strain gradients, and longitudinal strain rates related to regional patterns in cortical growth, porosity, remodelling and collagen fibre orientation. Although porosity and remodelling decreased and increased with age, respectively, these features showed no significant regional differences and did not correspond to regional patterns in the mechanical environment. Thicker regions of the radius's cortex were significantly related to high strain levels and higher rates of periosteal, but not endosteal, growth. However, cortical growth and strain environment were not significantly related. Collagen fibre orientation varied regionally, with a higher percentage of transverse fibres in the caudal region of the radius and primarily longitudinal fibres elsewhere, and, although consistent through growth, also did not generally correspond to regional strain patterns. Although strain magnitudes increased during ontogeny and regional strain patterns were variable over the course of a stride, mean regional strain patterns were generally consistent with growth, suggesting that regional growth patterns and histomorphology, in combination with external loads, may play some role in producing a relatively ‘predictable’ strain environment within the radius. It is further hypothesized that the absence of correlation between regional histomorphometric patterns and the
Yong Ji, Sang; Dewire, Jane; Barcelon, Bernadette; Philips, Binu; Catanzaro, John; Nazarian, Saman; Cheng, Alan; Spragg, David; Tandri, Harikrishna; Bansal, Sandeep; Ashikaga, Hiroshi; Rickard, Jack; Kolandaivelu, Aravindan; Sinha, Sunil; Marine, Joseph E; Calkins, Hugh; Berger, Ronald
2013-10-01
Phrenic nerve injury (PNI) is a well-known, although uncommon, complication of pulmonary vein isolation (PVI) using radiofrequency energy. Currently, there is no consensus about how to avoid or minimize this injury. The purpose of this study was to determine how often the phrenic nerve, as identified using a high-output pacing, lies along the ablation trajectory of a wide-area circumferential lesion set. We also sought to determine if PVI can be achieved without phrenic nerve injury by modifying the ablation lesion set so as to avoid those areas where phrenic nerve capture (PNC) is observed. We prospectively enrolled 100 consecutive patients (age 61.7 ± 9.2 years old, 75 men) who underwent RF PVI using a wide-area circumferential ablation approach. A high-output (20 mA at 2 milliseconds) endocardial pacing protocol was performed around the right pulmonary veins and the carina where a usual ablation lesion set would be made. A total of 30% of patients had PNC and required modification of ablation lines. In the group of patients with PNC, the carina was the most common site of capture (85%) followed by anterior right superior pulmonary vein (RSPV) (70%) and anterior right inferior pulmonary vein (RIPV) (30%). A total of 25% of PNC group had capture in all 3 (RSPV, RIPV, and carina) regions. There was no difference in the clinical characteristics between the groups with and without PNC. RF PVI caused no PNI in either group. High output pacing around the right pulmonary veins and the carina reveals that the phrenic nerve lies along a wide-area circumferential ablation trajectory in 30% of patients. Modification of ablation lines to avoid these sites may prevent phrenic nerve injury during RF PVI. © 2013 Wiley Periodicals, Inc.
Jiao, Yang; Li, Guangxin; Korneva, Arina; Caulk, Alexander W; Qin, Lingfeng; Bersi, Matthew R; Li, Qingle; Li, Wei; Mecham, Robert P; Humphrey, Jay D; Tellides, George
2017-05-01
Williams syndrome is characterized by obstructive aortopathy attributable to heterozygous loss of ELN , the gene encoding elastin. Lesions are thought to result primarily from excessive smooth muscle cell (SMC) proliferation and consequent medial expansion, although an initially smaller caliber and increased stiffness of the aorta may contribute to luminal narrowing. The relative contributions of such abnormalities to the obstructive phenotype had not been defined. We quantified determinants of luminal stenosis in thoracic aortas of Eln -/- mice incompletely rescued by human ELN . Moderate obstruction was largely because of deficient circumferential growth, most prominently of ascending segments, despite increased axial growth. Medial thickening was evident in these smaller diameter elastin-deficient aortas, with medial area similar to that of larger diameter control aortas. There was no difference in cross-sectional SMC number between mutant and wild-type genotypes at multiple stages of postnatal development. Decreased elastin content was associated with medial fibrosis and reduced aortic distensibility because of increased structural stiffness but preserved material stiffness. Elastin-deficient SMCs exhibited greater contractile-to-proliferative phenotypic modulation in vitro than in vivo. We confirmed increased medial collagen without evidence of increased medial area or SMC number in a small ascending aorta with thickened media of a Williams syndrome subject. Deficient circumferential growth is the predominant mechanism for moderate obstructive aortic disease resulting from partial elastin deficiency. Our findings suggest that diverse aortic manifestations in Williams syndrome result from graded elastin content, and SMC hyperplasia causing medial expansion requires additional elastin loss superimposed on ELN haploinsufficiency. © 2017 American Heart Association, Inc.
Li, Yanmin; Liu, Hao; Hao, Siwen; Li, Hongyi; Han, Jianda; Yang, Yunsheng
2017-03-01
Robot-assisted manipulation is promising for solving problems such as understaffing and the risk of infection in gastro-intestinal endoscopy. However, the commonly used friction rollers in few existing systems have a potential risk of deforming flexible endoscopes for non-uniform clamping. This paper presents a robotic system for a standard flexible endoscope and focuses on a novel gastroscope intervention mechanism (GIM), which provides circumferentially uniform clamping with an airbag. The GIM works with a relay-on mechanism in a way similar to manual operation. The shear stiffness of airbag and the critical slipping force (CSF) were analysed to determine the parameters of the airbag. A fuzzy PID controller was employed to realize a fast response and high accuracy of pneumatic actuation. Experiments were performed to evaluate the accuracy, stiffness and CSF. In vitro and in vivo animal experiments were also carried out. The GIM realized an accuracy of 0.025 ± 0.2 mm and -0.03 ± 0.25° for push-pull and rotation without delivery resistance. Under < 10 N delivery resistance, the error caused by the airbag stiffness was < 0.24 mm. A quadratic polynomial could be used to describe the relationship between the CSF and pneumatic pressure. The novel GIM could effectively deliver gastroscopes. The pneumatic-driven clamping method proposed could protect the gastroscope by circumferentially uniform clamping force and the CSF could be properly controlled to guarantee operating safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Circumferential Peyronie's disease involving both the corpora cavernosa.
Narita, T; Kudo, H; Matsumoto, K
1995-05-01
An extraordinary form of Peyronies disease is reported. The patient was a 52 year old male, who died of a malignant thymoma with multiple bone metastasis, extensive pleural carcinomatosis of the left lung and some metastatic nodules in the liver and the mesenterium. At autopsy, the proximal and middle portions of the penis were very hard. Macroscopically, the entire tunica albuginea of both the corpora cavernosa was markedly thickened, 2-4 mm; and calcified. Microscopically, the tunica albuginea showed extensive hyaline degeneration, calcification and ossifying foci with osteoblasts and osteoclasts. Inflammatory cells were frequently found beneath the thickened tunica albuginea. In the corpus cavernosum, cavernous arteries showed marked intimal thickening and medial muscular degeneration with a few inflammatory cells. Smooth muscles of the stroma were extensively atrophic and degenerative, and some of them were infiltrated with a few inflammatory cells. In the corpus spongiosum, the tunica albuginea was not thickened, but the smooth muscle in the stroma was atrophic and degenerative and a few inflammatory cells were also found. Surprisingly, there was no Littrés gland around the urethra. In Peyronies disease, the dorsal part of the penis is usually involved, and less frequently lateral or ventral sites are involved. The circumferential involvement of both the corpora cavernosa has not been reported until now, as far as the authors know.
Metcalfe, Stephen; Gbejuade, Herbert; Patel, Nitin R
2012-07-15
A retrospective case series. To demonstrate the feasibility, safety, and results of the posterior transpedicular approach for circumferential decompression and instrumented reconstruction of thoracolumbar spinal tumors. Patients presenting with spinal tumor disease requiring 3-column instrumented stabilization are typically treated with a combined anterior and posterior surgical approach. However, circumferential decompression and instrumented stabilization may also be achieved through a single-stage, midline posterior transpedicular approach. Fifty consecutive patients (27 women and 23 men) underwent surgery between 2003 and 2010 at a single institution by the senior author. Mean age was 55.9 years (range, 25-79 yr).Single or multilevel, contiguous subtotal vertebrectomy was performed ranging from T1 to L4 (38 thoracic and 12 lumbar). Three-column spinal stabilization was achieved using posterior pedicle screw fixation and vertebral body reconstruction, with a titanium cage introduced through the posterior transpedicular route. The mean follow-up period was 17 months (range, 1-54 mo). The mean operating time was 4.2 hours. The mean estimated blood loss for a subgroup of 9 patients with hypervascular tumor pathology was 3933 mL (range, 2700-5800 mL). The mean blood loss in the remaining 41 patients was 1262 mL (range, 250-2500 mL).Postoperative neurological status was maintained or improved in all patients. Mean postoperative stay was 7.7 days (range, 3-12 d). At last review, 14 patients were alive, with a mean survival of 36 months (range, 13-71 mo). The mean survival for the 36 patients who died was 19 months (range, 2 weeks to 54 mo). This is the largest reported series of patients with spinal tumor disease undergoing circumferential decompression and 3-column instrumented stabilization through the posterior transpedicular approach.This surgical approach provides sufficient access for safe and effective circumferential decompression and stabilization, with
Effects of laser-aided circumferential supracrestal fiberotomy on root surfaces.
Lee, Ji-Won; Park, Ki-Ho; Chung, Jong-Hyuk; Kim, Su-Jung
2011-11-01
To evaluate and compare the effects of circumferential supracrestal fiberotomy in vivo (using diode, CO(2), and Er∶YAG lasers) on the morphology and chemical composition of the root surface. Forty healthy premolar teeth, intended for extraction for orthodontic reasons, were used in this study. Root surfaces were treated using different laser methods, as follows: (1) control; (2) Er∶YAG laser (2.94 µm, 100 mJ, 10 Hz); (3) diode laser (808 nm, 1.2 W, continuous wave); and (4) CO(2) laser (10.6 µm, 3 W, continuous wave). Subsequently, the teeth were removed and subjected to scanning electron microscopic (SEM) examination and energy dispersive x-ray (EDX) spectrometric analysis. SEM analysis indicated that no thermal changes, including melting or carbonization, were observed following the lasing procedures. EDX analysis showed that the laser procedures resulted in similar mineral contents (weight % of calcium and phosphate) as compared to those in the control group. Based on these findings, we concluded that laser-aided procedures, when used at appropriate laser settings, preserve the original morphology and chemical composition of cementum.
NASA Technical Reports Server (NTRS)
Panontin, Tina L.; Sheppard, Sheri D.
1994-01-01
The use of small laboratory specimens to predict the integrity of large, complex structures relies on the validity of single parameter fracture mechanics. Unfortunately, the constraint loss associated with large scale yielding, whether in a laboratory specimen because of its small size or in a structure because it contains shallow flaws loaded in tension, can cause the breakdown of classical fracture mechanics and the loss of transferability of critical, global fracture parameters. Although the issue of constraint loss can be eliminated by testing actual structural configurations, such an approach can be prohibitively costly. Hence, a methodology that can correct global fracture parameters for constraint effects is desirable. This research uses micromechanical analyses to define the relationship between global, ductile fracture initiation parameters and constraint in two specimen geometries (SECT and SECB with varying a/w ratios) and one structural geometry (circumferentially cracked pipe). Two local fracture criteria corresponding to ductile fracture micromechanisms are evaluated: a constraint-modified, critical strain criterion for void coalescence proposed by Hancock and Cowling and a critical void ratio criterion for void growth based on the Rice and Tracey model. Crack initiation is assumed to occur when the critical value in each case is reached over some critical length. The primary material of interest is A516-70, a high-hardening pressure vessel steel sensitive to constraint; however, a low-hardening structural steel that is less sensitive to constraint is also being studied. Critical values of local fracture parameters are obtained by numerical analysis and experimental testing of circumferentially notched tensile specimens of varying constraint (e.g., notch radius). These parameters are then used in conjunction with large strain, large deformation, two- and three-dimensional finite element analyses of the geometries listed above to predict crack
Matta, Ragai E; Schmitt, Johannes; Wichmann, Manfred; Holst, Stefan
2012-10-01
Techniques currently applied to determine the marginal accuracy of dental crown restorations yield inadequate information. This investigation aimed to test a new virtual approach for determining the precision of fit of single-crown copings. Zirconia single crown copings were manufactured on 10 gypsum, single-tooth master casts with two different established computer-aided design/computer-assisted manufacture (CAD/CAM) systems (groups A and B). After cementation, the circumferential fit was assessed with an industrial noncontact scanner and virtual 3D analysis, following a triple-scan protocol. Marginal fit was determined by virtual sectioning; each abutment-coping complex was digitally sliced in 360 vertical sections (1 degree per section). Standardized measurement distances for analyzing the marginal fit (z, xy, xyz) were selected, and a crosshair alignment was utilized to determine whether crowns were horizontally and/or vertically too large or small. The Mann-Whitney test was applied to test for differences between groups. Significant differences in the xy direction (P = .008) were measured between groups. Group A showed a greater number of horizontally overextended margins and a higher frequency of xy distances greater than 150 Μm, in addition to a tendency for excessive z distances (P = .095). The mean marginal gap values were clinically acceptable in the present investigation; however, a full circumferential analysis revealed significant differences in marginal coping quality.
Salerno, G; Daniels, I R; Brown, G; Norman, A R; Moran, B J; Heald, R J
2007-06-01
The objective of this study was to assess the value of preoperative pelvimetry, using magnetic resonance imaging (MRI), in predicting the risk of an involved circumferential resection margin (CRM) in a group of patients with operable rectal cancer. A cohort of 186 patients from the MERCURY study was selected. These patients' histological CRM status was compared against 14 pelvimetry parameters measured from the preoperative MRI. These measurements were taken by one of the investigators (G.S.), who was blinded to the final CRM status. There was no correlation between the pelvimetry and the CRM status. However, there was a difference in the height of the rectal cancer and the positive CRM rate (p = 0.011). Of 61 patients with low rectal cancer, 10 had positive CRM at histology (16.4% with CI 8.2%-22.1%) compared with 5 of 110 patients with mid/upper rectal cancers (4.5% with CI 0.7%-8.4%). Magnetic resonance imaging can predict clear margins in most cases of rectal cancer. Circumferential resection margin positivity cannot be predicted from pelvimetry in patients with rectal cancer selected for curative surgery. The only predictive factor for a positive CRM in the patients studied was tumor height.
Aoki, Shigehisa; Sakata, Yasuhisa; Shimoda, Ryo; Takezawa, Toshiaki; Oshikata-Miyazaki, Ayumi; Kimura, Hiromi; Yamamoto, Mihoko; Iwakiri, Ryuichi; Fujimoto, Kazuma; Toda, Shuji
2017-05-01
Extensive excision of the esophageal mucosa by endoscopic submucosal dissection (ESD) frequently evokes a luminal stricture. This study aimed to determine the efficacy of a high-density collagen patch for the prevention of esophageal stricture in extensive ESD. Six pigs underwent circumferential esophageal ESD under general anesthesia. In 3 pigs, artificial ulcers were covered by 2 collagen patches. The other 3 pigs underwent circumferential ESD only. The 2 collagen patches were settled onto the ulcer surface using a general endoscope and instruments. The collagen patch-treated group showed significantly better patency rates on both the oral and anal sides of the wound area compared with the control group at day 14. The mucosal re-epithelization ratio was significantly promoted, and the extent of mucosal inflammation and fibrosis was significantly decreased with the collagen patch treatment in the wound area. The frequency of cells positive α-smooth muscle actin was significantly reduced in the collagen patch-treated group compared with the control group. We have established a high-density collagen device that can reduce the esophageal stricture associated with extensive ESD. This easy-to-handle device would be useful during superficial esophageal cancer treatment by ESD. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Manson, Abigail L; Cohen, Keira A; Abeel, Thomas; Desjardins, Christopher A; Armstrong, Derek T; Barry, Clifton E; Brand, Jeannette; Chapman, Sinéad B; Cho, Sang-Nae; Gabrielian, Andrei; Gomez, James; Jodals, Andreea M; Joloba, Moses; Jureen, Pontus; Lee, Jong Seok; Malinga, Lesibana; Maiga, Mamoudou; Nordenberg, Dale; Noroc, Ecaterina; Romancenco, Elena; Salazar, Alex; Ssengooba, Willy; Velayati, A A; Winglee, Kathryn; Zalutskaya, Aksana; Via, Laura E; Cassell, Gail H; Dorman, Susan E; Ellner, Jerrold; Farnia, Parissa; Galagan, James E; Rosenthal, Alex; Crudu, Valeriu; Homorodean, Daniela; Hsueh, Po-Ren; Narayanan, Sujatha; Pym, Alexander S; Skrahina, Alena; Swaminathan, Soumya; Van der Walt, Martie; Alland, David; Bishai, William R; Cohen, Ted; Hoffner, Sven; Birren, Bruce W; Earl, Ashlee M
2017-03-01
Multidrug-resistant tuberculosis (MDR-TB), caused by drug-resistant strains of Mycobacterium tuberculosis, is an increasingly serious problem worldwide. Here we examined a data set of whole-genome sequences from 5,310 M. tuberculosis isolates from five continents. Despite the great diversity of these isolates with respect to geographical point of isolation, genetic background and drug resistance, the patterns for the emergence of drug resistance were conserved globally. We have identified harbinger mutations that often precede multidrug resistance. In particular, the katG mutation encoding p.Ser315Thr, which confers resistance to isoniazid, overwhelmingly arose before mutations that conferred rifampicin resistance across all of the lineages, geographical regions and time periods. Therefore, molecular diagnostics that include markers for rifampicin resistance alone will be insufficient to identify pre-MDR strains. Incorporating knowledge of polymorphisms that occur before the emergence of multidrug resistance, particularly katG p.Ser315Thr, into molecular diagnostics should enable targeted treatment of patients with pre-MDR-TB to prevent further development of MDR-TB.
Pauli, Eric M; Schomisch, Steve J; Furlan, Joseph P; Marks, Andrea S; Chak, Amitabh; Lash, Richard H; Ponsky, Jeffrey L; Marks, Jeffrey M
2012-12-01
Advanced esophageal dysplasia and early cancers have been treated traditionally with esophagectomy. Endoscopic esophageal mucosectomy (EEM) offers less-invasive therapy, but high-degree stricture formation limits its applicability. We hypothesized that placement of a biodegradable stent (BD-stent) immediately after circumferential EEM would prevent stricturing. Ten pigs (five unstented controls, five BD-stent) were utilized. Under anesthesia, a flexible endoscope with a band ligator and snare was used to incise the mucosa approximately 20 cm proximal to the lower esophageal sphincter. A 10-cm, circumferential, mucosal segment was dissected and excised by using snare electrocautery. In the stented group, an 18-×120-mm, self-expanding, woven polydioxanone stent (ELLA-CS, Hradec-Kralove) was deployed. Weekly esophagograms evaluated for percent reduction in esophageal diameter, stricture length, and proximal esophageal dilation. Animals were euthanized when the stricture exceeded 80% and were unable to gain weight (despite high-calorie liquid diet) or at 14 weeks. The control group rapidly developed esophageal strictures; no animal survived beyond the third week of evaluation. At 2 weeks post-EEM, the BD-stent group had a significant reduction in esophageal diameter (77.7 vs. 26.6%, p < 0.001) and degree of proximal dilation (175 vs. 131%, p = 0.04) compared with controls. Survival in the BD-stent group was significantly longer than in the control group (9.2 vs. 2.4 weeks, p = 0.01). However, all BD-stent animals ultimately developed clinically significant strictures (range, 4-14 weeks). Comparison between the maximum reduction in esophageal diameter and stricture length (immediately before euthanasia) demonstrated no differences between the groups. Circumferential EEM results in severe stricture formation and clinical deterioration within 3 weeks. BD-stent placement significantly delays the time of clinical deterioration from 2.4 to 9.2 weeks, but does not affect the
Barret, Maximilien; Pratico, Carlos Alberto; Camus, Marine; Beuvon, Frédéric; Jarraya, Mohamed; Nicco, Carole; Mangialavori, Luigi; Chaussade, Stanislas; Batteux, Frédéric; Prat, Frédéric
2014-01-01
The prevention of esophageal strictures following circumferential mucosal resection remains a major clinical challenge. Human amniotic membrane (AM) is an easily available material, which is widely used in ophthalmology due to its wound healing, anti-inflammatory and anti-fibrotic properties. We studied the effect of AM grafts in the prevention of esophageal stricture after endoscopic submucosal dissection (ESD) in a swine model. In this prospective, randomized controlled trial, 20 swine underwent a 5 cm-long circumferential ESD of the lower esophagus. In the AM Group (n = 10), amniotic membrane grafts were placed on esophageal stents; a subgroup of 5 swine (AM 1 group) was sacrificed on day 14, whereas the other 5 animals (AM 2 group) were kept alive. The esophageal stent (ES) group (n = 5) had ES placement alone after ESD. Another 5 animals served as a control group with only ESD. The prevalence of symptomatic strictures at day 14 was significantly reduced in the AM group and ES groups vs. the control group (33%, 40% and 100%, respectively, p = 0.03); mean esophageal diameter was 5.8±3.6 mm, 6.8±3.3 mm, and 2.6±1.7 mm for AM, ES, and control groups, respectively. Median (range) esophageal fibrosis thickness was 0.87 mm (0.78-1.72), 1.19 mm (0.28-1.95), and 1.65 mm (0.7-1.79) for AM 1, ES, and control groups, respectively. All animals had developed esophageal strictures by day 35. The anti-fibrotic effect of AM on esophageal wound healing after ESD delayed the development of esophageal stricture in our model. However, this benefit was of limited duration in the conditions of our study.
Barret, Maximilien; Pratico, Carlos Alberto; Camus, Marine; Beuvon, Frédéric; Jarraya, Mohamed; Nicco, Carole; Mangialavori, Luigi; Chaussade, Stanislas; Batteux, Frédéric; Prat, Frédéric
2014-01-01
Background and Aims The prevention of esophageal strictures following circumferential mucosal resection remains a major clinical challenge. Human amniotic membrane (AM) is an easily available material, which is widely used in ophthalmology due to its wound healing, anti-inflammatory and anti-fibrotic properties. We studied the effect of AM grafts in the prevention of esophageal stricture after endoscopic submucosal dissection (ESD) in a swine model. Animals and Methods In this prospective, randomized controlled trial, 20 swine underwent a 5 cm-long circumferential ESD of the lower esophagus. In the AM Group (n = 10), amniotic membrane grafts were placed on esophageal stents; a subgroup of 5 swine (AM 1 group) was sacrificed on day 14, whereas the other 5 animals (AM 2 group) were kept alive. The esophageal stent (ES) group (n = 5) had ES placement alone after ESD. Another 5 animals served as a control group with only ESD. Results The prevalence of symptomatic strictures at day 14 was significantly reduced in the AM group and ES groups vs. the control group (33%, 40% and 100%, respectively, p = 0.03); mean esophageal diameter was 5.8±3.6 mm, 6.8±3.3 mm, and 2.6±1.7 mm for AM, ES, and control groups, respectively. Median (range) esophageal fibrosis thickness was 0.87 mm (0.78–1.72), 1.19 mm (0.28–1.95), and 1.65 mm (0.7–1.79) for AM 1, ES, and control groups, respectively. All animals had developed esophageal strictures by day 35. Conclusions The anti-fibrotic effect of AM on esophageal wound healing after ESD delayed the development of esophageal stricture in our model. However, this benefit was of limited duration in the conditions of our study. PMID:24992335
Cioffi, Giovanni; Mazzone, Carmine; Barbati, Giulia; Rossi, Andrea; Nistri, Stefano; Ognibeni, Federica; Tarantini, Luigi; Di Lenarda, Andrea; Faggiano, Pompilio; Pulignano, Giovanni; Stefenelli, Carlo; de Simone, Giovanni; Devereux, Richard B
2015-07-01
Early detection of left ventricular (LV) systolic dysfunction is pivotal in the management of patients with aortic stenosis (AS). LV circumferential and/or longitudinal shortening may be impaired in these patients despite LV ejection fraction is preserved. We focused on prevalence and factors associated with combined impairment of circumferential and longitudinal shortening (C&L) in asymptomatic AS patients. Echocardiographic and clinical data from 200 patients with asymptomatic AS of any degree without history of heart failure and normal LV ejection fraction were analyzed. C&L were evaluated by mid-wall shortening (MS) and tissue Doppler mitral annular peak systolic velocity (S'), and classified low if <16.5% and if <8.5 cm/sec, respectively (10th percentiles of controls). Combined C&L dysfunction was detected in 72 patients (36%). The variables associated with this condition were higher LV mass (OR 1.02 [CI 1.01-1.04], P = 0.03), concentric LV geometry (OR 4.30 [CI 1.79-10.34], P = 0.001), increasing pulmonary artery wedge pressure (by E/e' ratio; OR 1.11 [CI 1.04-1.19], P = 0.001). The relation of MS and peak S' was linear and slightly significant in the whole population (r = 0.23; F statistic=0.001), absent in patients with C&L dysfunction (r = 0.04; F = ns), negative (linear model) in the subgroup of patients without C&L dysfunction (r = -0.22; F = 0.02). C&L dysfunction is present in more than one-third of patients with asymptomatic AS and is associated with concentric LV geometry and higher degree of diastolic dysfunction. The relation between MS and peak S' largely varies in the subgroups with different C&L function. © 2014, Wiley Periodicals, Inc.
Yang, Woo-In; Shim, Chi Y; Bang, Woo D; Oh, Chang M; Chang, Hyuk J; Chung, Namsik; Ha, Jong-Won
2011-12-01
Arterial elastic properties change with aging. Measurements of pulse wave velocity and augmentation index are useful for the evaluation of arterial stiffness. However, they likely represent only global characteristics of the arterial tree rather than local vascular alterations. The aim of this study was to evaluate whether local vascular properties assessed by velocity vector imaging differed with aging. Vascular properties of carotid arteries with ages were assessed in 100 healthy volunteers (52 men) ranging from 20 to 68 years using velocity vector imaging. The peak circumferential strain and strain rate of the six segments in left common carotid arteries were analyzed and the standard deviation of the time to peak circumferential strain and strain rate of the six segments, representing the synchronicity of the arterial expansion, were calculated. Central blood pressure, augmentation index and pulse wave velocity were assessed by commercially available radial artery tonometry, the SphygmoCor system (AtCor Medical, West Ryde, Australia). A validated generalized transfer function was used to acquire the central aortic pressures and pressure waveforms. Pulse wave velocity, augmentation index and velocity vector imaging parameters showed significant changes with age. However, the age-related changes in pulse wave velocity, augmentation index and velocity vector imaging parameters were different. The increase in pulse wave velocity was more prominent in older individuals, whereas the changes in augmentation index and carotid strain and strain rate were evident earlier, at the age of 30 years. Unlike augmentation index, which showed little change in older individuals, the standard deviation of time to peak strain and strain rate showed a steady increase from younger to older individuals. Asynchronous arterial expansion could be a useful discriminative marker of vascular aging independent of individual's age.
Levin, David A; Bendo, John A; Quirno, Martin; Errico, Thomas; Goldstein, Jeffrey; Spivak, Jeffrey
2007-12-01
This is a retrospective, independent study comparing 2 groups of patients treated surgically for discogenic low back pain associated with degenerative disc disease (DDD) in the lumbosacral spine. To compare the surgical and hospitalization charges associated with 1- and 2-level lumbar total disc replacement and circumferential lumbar fusion. Reported series of lumbar total disc replacement have been favorable. However, economic aspects of lumbar total disc replacement (TDR) have not been published or studied. This information is important considering the recent widespread utilization of new technologies. Recent studies have demonstrated comparable short-term clinical results between TDR and lumbar fusion recipients. Relative charges may be another important indicator of the most appropriate procedure. We report a hospital charge-analysis comparing ProDisc lumbar disc replacement with circumferential fusion for discogenic low back pain. In a cohort of 53 prospectively selected patients with severe, disabling back pain and lumbar disc degeneration, 36 received Synthes ProDisc TDR and 17 underwent circumferential fusion for 1- and 2-level degenerative disc disease between L3 and S1. Randomization was performed using a 2-to-1 ratio of ProDisc recipients to control spinal fusion recipients. Charge comparisons, including operating room charges, inpatient hospital charges, and implant charges, were made from hospital records using inflation-corrected 2006 U.S. dollars. Operating room times, estimated blood loss, and length of stay were obtained from hospital records as well. Surgeon and anesthesiologist fees were, for the purposes of comparison, based on Medicare reimbursement rates. Statistical analysis was performed using a 2-tailed Student t test. For patients with 1-level disease, significant differences were noted between the TDR and fusion control group. The mean total charge for the TDR group was $35,592 versus $46,280 for the fusion group (P = 0.0018). Operating
Shiino, Kenji; Yamada, Akira; Ischenko, Matthew; Khandheria, Bijoy K; Hudaverdi, Mahala; Speranza, Vicki; Harten, Mary; Benjamin, Anthony; Hamilton-Craig, Christian R; Platts, David G; Burstow, Darryl J; Scalia, Gregory M; Chan, Jonathan
2017-06-01
We aimed to assess intervendor agreement of global (GLS) and regional longitudinal strain by vendor-specific software after EACVI/ASE Industry Task Force Standardization Initiatives for Deformation Imaging. Fifty-five patients underwent prospective dataset acquisitions on the same day by the same operator using two commercially available cardiac ultrasound systems (GE Vivid E9 and Philips iE33). GLS and regional peak longitudinal strain were analyzed offline using corresponding vendor-specific software (EchoPAC BT13 and QLAB version 10.3). Absolute mean GLS measurements were similar between the two vendors (GE -17.5 ± 5.2% vs. Philips -18.9 ± 5.1%, P = 0.15). There was excellent intervendor correlation of GLS by the same observer [r = 0.94, P < 0.0001; bias -1.3%, 95% CI limits of agreement (LOA) -4.8 to 2.2%). Intervendor comparison for regional longitudinal strain by coronary artery territories distribution were: LAD: r = 0.85, P < 0.0001; bias 0.5%, LOA -5.3 to 6.4%; RCA: r = 0.88, P < 0.0001; bias -2.4%, LOA -8.6 to 3.7%; LCX: r = 0.76, P < 0.0001; bias -5.3%, LOA -10.6 to 2.0%. Intervendor comparison for regional longitudinal strain by LV levels were: basal: r = 0.86, P < 0.0001; bias -3.6%, LOA -9.9 to 2.0%; mid: r = 0.90, P < 0.0001; bias -2.6%, LOA -7.8 to 2.6%; apical: r = 0.74; P < 0.0001; bias -1.3%, LOA -9.4 to 6.8%. Intervendor agreement in GLS and regional strain measurements have significantly improved after the EACVI/ASE Task Force Strain Standardization Initiatives. However, significant wide LOA still exist, especially for regional strain measurements, which remains relevant when considering vendor-specific software for serial measurements. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Pirat, Bahar; Khoury, Dirar S.; Hartley, Craig J.; Tiller, Les; Rao, Liyun; Schulz, Daryl G.; Nagueh, Sherif F.; Zoghbi, William A.
2012-01-01
Objectives The aim of this study was to validate a novel, angle-independent, feature-tracking method for the echocardiographic quantitation of regional function. Background A new echocardiographic method, Velocity Vector Imaging (VVI) (syngo Velocity Vector Imaging technology, Siemens Medical Solutions, Ultrasound Division, Mountain View, California), has been introduced, based on feature tracking—incorporating speckle and endocardial border tracking, that allows the quantitation of endocardial strain, strain rate (SR), and velocity. Methods Seven dogs were studied during baseline, and various interventions causing alterations in regional function: dobutamine, 5-min coronary occlusion with reperfusion up to 1 h, followed by dobutamine and esmolol infusions. Echocardiographic images were acquired from short- and long-axis views of the left ventricle. Segment-length sonomicrometry crystals were used as the reference method. Results Changes in systolic strain in ischemic segments were tracked well with VVI during the different states of regional function. There was a good correlation between circumferential and longitudinal systolic strain by VVI and sonomicrometry (r = 0.88 and r = 0.83, respectively, p < 0.001). Strain measurements in the nonischemic basal segments also demonstrated a significant correlation between the 2 methods (r = 0.65, p < 0.001). Similarly, a significant relation was observed for circumferential and longitudinal SR between the 2 methods (r = 0.94, p < 0.001 and r = 0.90, p < 0.001, respectively). The endocardial velocity relation to changes in strain by sonomicrometry was weaker owing to significant cardiac translation. Conclusions Velocity Vector Imaging, a new feature-tracking method, can accurately assess regional myocardial function at the endocardial level and is a promising clinical tool for the simultaneous quantification of regional and global myocardial function. PMID:18261685
Pirat, Bahar; Khoury, Dirar S; Hartley, Craig J; Tiller, Les; Rao, Liyun; Schulz, Daryl G; Nagueh, Sherif F; Zoghbi, William A
2008-02-12
The aim of this study was to validate a novel, angle-independent, feature-tracking method for the echocardiographic quantitation of regional function. A new echocardiographic method, Velocity Vector Imaging (VVI) (syngo Velocity Vector Imaging technology, Siemens Medical Solutions, Ultrasound Division, Mountain View, California), has been introduced, based on feature tracking-incorporating speckle and endocardial border tracking, that allows the quantitation of endocardial strain, strain rate (SR), and velocity. Seven dogs were studied during baseline, and various interventions causing alterations in regional function: dobutamine, 5-min coronary occlusion with reperfusion up to 1 h, followed by dobutamine and esmolol infusions. Echocardiographic images were acquired from short- and long-axis views of the left ventricle. Segment-length sonomicrometry crystals were used as the reference method. Changes in systolic strain in ischemic segments were tracked well with VVI during the different states of regional function. There was a good correlation between circumferential and longitudinal systolic strain by VVI and sonomicrometry (r = 0.88 and r = 0.83, respectively, p < 0.001). Strain measurements in the nonischemic basal segments also demonstrated a significant correlation between the 2 methods (r = 0.65, p < 0.001). Similarly, a significant relation was observed for circumferential and longitudinal SR between the 2 methods (r = 0.94, p < 0.001 and r = 0.90, p < 0.001, respectively). The endocardial velocity relation to changes in strain by sonomicrometry was weaker owing to significant cardiac translation. Velocity Vector Imaging, a new feature-tracking method, can accurately assess regional myocardial function at the endocardial level and is a promising clinical tool for the simultaneous quantification of regional and global myocardial function.
Dmitriev, Anton E; Kuklo, Timothy R; Lehman, Ronald A; Rosner, Michael K
2007-03-15
This is an in vitro biomechanical study. The current investigation was performed to evaluate the stabilizing potential of anterior, posterior, and circumferential cervical fixation on operative and adjacent segment motion following 2 and 3-level reconstructions. Previous studies reported increases in adjacent level range of motion (ROM) and intradiscal pressure following single-level cervical arthrodesis; however, no studies have compared adjacent level effects following multilevel anterior versus posterior reconstructions. Ten human cadaveric cervical spines were biomechanically tested using an unconstrained spine simulator under axial rotation, flexion-extension, and lateral bending loading. After intact analysis, all specimens were sequentially instrumented from C3 to C5 with: (1) lateral mass fixation, (2) anterior cervical plate with interbody cages, and (3) combined anterior and posterior fixation. Following biomechanical analysis of 2-level constructs, fixation was extended to C6 and testing repeated. Full ROM was monitored at the operative and adjacent levels, and data normalized to the intact (100%). All reconstructive methods reduced operative level ROM relative to intact specimens under all loading methods (P < 0.05). However, circumferential fixation provided the greatest segmental stability among 2 and 3-level constructs (P < 0.05). Moreover, anterior cervical plate fixation was least efficient at stabilizing operative segments following C3-C6 arthrodesis (P < 0.05). Supradjacent ROM was increased for all treatment groups compared to normal data during flexion-extension testing (P < 0.05). Similar trends were observed under axial rotation and lateral bending loading. At the distal level, flexion-extension and axial rotation testing revealed comparable intergroup differences (P < 0.05), while lateral bending loading indicated greater ROM following 2-level circumferential fixation (P < 0.05). Results from our study revealed greater adjacent level motion
Rios, Rodrigo; Ginde, Salil; Saudek, David; Loomba, Rohit S; Stelter, Jessica; Frommelt, Peter
2017-01-01
Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice. A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports. A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients <10 vs. >10 years post-Fontan. Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability. © 2016, Wiley Periodicals, Inc.
Johnson, Christopher; Forsythe, Lynsey; Somauroo, John; Papadakis, Michael; George, Keith; Oxborough, David
2018-05-01
The aim of this exploratory study was to define the Athletes Heart (AH) phenotype in Native Hawaiian & Pacific Islander (NH&PI) Rugby Football League (RFL) athletes. Specifically, (1) to describe conventional echocardiographic indices of left ventricle (LV) and right ventricle (RV) structure and function in NH&PI RFL players and matched RFL Caucasian controls (CC) and (2) to demonstrate LV and RV mechanics in these populations. Ethnicity is a contributory factor to the phenotypical expression of the AH. There are no data describing the cardiac phenotype in NH&PI athletes. Twenty-one male elite NH&PI RFL athletes were evaluated using conventional echocardiography and myocardial speckle tracking, allowing the assessment of global longitudinal strain (ε) and strain rate (SR); and basal, mid and global radial and circumferential ε and SR. Basal and apical rotation and twist were also assessed. Results were compared with age-matched Caucasian counterparts (CC; n = 21). LV mass [42 ± 9 versus 37 ± 4 g/(m 2.7 )], mean LV wall thickness (MWT: 9.5 ± 0.7 and 8.7 ± 0.4 mm), relative wall thickness (RWT: 0.35 ± 0.04 and 0.31 ± 0.03) and RV wall thickness (5 ± 1 and 4 ± 1 mm, all p < 0.05) were greater in NH&PI compared with CC. LV and RV cavity dimensions and standard indices of LV and RV systolic and diastolic function were similar between groups. NH&PI demonstrated reduced peak LV mid circumferential ε and early diastolic SR, as well as reduced global radial ε. There was reduced basal rotation at 25-35% systole, reduced apical rotation at 25-40% and 60-100% systole and reduced twist at 85-95% systole in NH&PI athletes. There were no differences between the two groups in RV wall mechanics. When compared to Caucasian controls, NH&PI rugby players have a greater LV mass, MWT and RWT with concomitant reductions in circumferential and twist mechanics. This data acts to prompt further research in NH&PI athletes.
Pellerin, D; Sharma, R; Elliott, P; Veyrat, C
2003-01-01
Tissue Doppler (TDE), strain, and strain rate echocardiography are emerging real time ultrasound techniques that provide a measure of wall motion. They offer an objective means to quantify global and regional left and right ventricular function and to improve the accuracy and reproducibility of conventional echocardiography studies. Radial and longitudinal ventricular function can be assessed by the analysis of myocardial wall velocity and displacement indices, or by the analysis of wall deformation using the rate of deformation of a myocardial segment (strain rate) and its deformation over time (strain). A quick and easy assessment of left ventricular ejection fraction is obtained by mitral annular velocity measurement during a routine study, especially in patients with poor endocardial definition or abnormal septal motion. Strain rate and strain are less affected by passive myocardial motion and tend to be uniform throughout the left ventricle in normal subjects. This paper reviews the underlying principles of TDE, strain, and strain rate echocardiography and discusses currently available quantification tools and clinical applications. PMID:14594870
Effects of replicative fitness on competing HIV strains.
Chirove, Faraimunashe; Lungu, Edward M
2013-07-01
We develop an n-strain model to show the effects of replicative fitness of competing viral strains exerting selective density-dependant infective pressure on each other. A two strain model is used to illustrate the results. A perturbation technique and numerical simulations were used to establish the existence and stability of steady states. More than one infected steady states governed by the replicative fitness resulted from the model exhibiting either strain replacement or co-infection. We found that the presence of two or more HIV strains could result in a disease-free state that, in general, is not globally stable. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Parker, Katherine M.; Clark, Alexander P.; Goodman, Norman C.; Glover, David K.; Holmes, Jeffrey W.
2015-01-01
Background Quantitative analysis of wall motion from three-dimensional (3D) dobutamine stress echocardiography (DSE) could provide additional diagnostic information not available from qualitative analysis. In this study we compare the effectiveness of 3D fractional shortening (3DFS), a measure of wall motion computed from 3D echocardiography (3DE), to strain and strain rate measured with sonomicrometry for detecting critical stenoses during DSE. Methods Eleven open-chest dogs underwent DSE both with and without a critical stenosis. 3DFS was measured from 3DE images acquired at peak stress. 3DFS was normalized by subtracting average 3DFS during control peak stress (Δ3DFS). Strains in the perfusion defect (PD) were measured from sonomicrometry, and PD size and location were measured with microspheres. Results A Δ3DFS abnormality indicated the presence of a critical stenosis with high sensitivity and specificity (88% and 100%, respectively), and Δ3DFS abnormality size correlated with PD size (R2=0.54). The sensitivity and specificity for Δ3DFS was similar to that for area strain (88%, 100%) and circumferential strain and strain rate (88%, 92% and 88%, 86%, respectively), while longitudinal strain and strain rate were less specific. Δ3DFS correlated significantly with both coronary flow reserve (R2=0.71) and PD size (R2=0.97), while area strain correlated with PD size only (R2=0.67), and other measures were not significantly correlated with flow reserve or PD size. Conclusion Quantitative wall motion analysis using Δ3DFS is effective for detecting critical stenoses during DSE, performing similarly to 3D strain, and provides potentially useful information on the size and location of a perfusion defect. PMID:24815588
NASA Technical Reports Server (NTRS)
Horton, Karla Renee
2011-01-01
Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks. Friction plug welding is used to seal the exit hole that remains in a circumferential SR-FSW. This work reports on material properties and strain patterns developed in a SR-FSW with a friction plug weld. Specifically, this study examines the behavior of a SR-FSW formed between an AA 2014-T6 plate on the advancing side and an AA 2219-T87 plate on the retreating side and a SR-FSW (AA 2014-T6 to AA 2219-T87) with a 2219-T87 plug weld. This study presents the results of a characterization of the micro-hardness, joint strength, and strain field characterization of SR-FSW and FPW joints tested at room temperature and cryogenic temperatures.
Freutel, Maren; Seitz, Andreas M; Ignatius, Anita; Dürselen, Lutz
2015-01-01
Numerous studies investigated the reasons for premature osteoarthritis due to partial meniscectomy (PM). However, the influence of meniscectomy on attachment forces and superficial strain of the tibial meniscus is unclear. It is hypothesised that these parameters depend on the degree of PM. Six porcine medial menisci were placed in a custom made apparatus, and each meniscal attachment was connected to a force sensor. After printing markers onto the tibial meniscal surfaces, the menisci were positioned on a glass plate enabling optical superficial strain measurement. Additionally, contact area and pressure were investigated. Each meniscus was axially loaded up to 650 N using its respective femoral condyle. Testing was conducted intact and after 50 and 75% PM of the posterior horn and extending 75% PM to the anterior horn. With increasing meniscectomy, the attachment forces decreased anteriorly by up to 17% (n.s.) and posteriorly by up to 55% (p = 0.003). The circumferential strain in the peripheral meniscal zones was not affected by the meniscectomy, while in some meniscal zones the radial strain changed from compression to tension. Contact area decreased by up to 23% (p = 0.01), resulting in an increase in 40% (p = 0.02) for the maximum contact pressure. Partial meniscectomy significantly alters the loading situation of the meniscus and its attachments. Specifically, the attachment forces decreased with increasing amount of meniscal tissue loss, which reflects the impaired ability of the meniscus to transform axial joint load into meniscal hoop stress.
Zweerink, Alwin; Allaart, Cornelis P; Kuijer, Joost P A; Wu, LiNa; Beek, Aernout M; van de Ven, Peter M; Meine, Mathias; Croisille, Pierre; Clarysse, Patrick; van Rossum, Albert C; Nijveldt, Robin
2017-12-01
Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. • Myocardial strain analysis could potentially improve patient selection for CRT. • Currently a well validated clinical approach to derive segmental strains is lacking. • The novel SLICE technique derives segmental strains from standard CMR cine images. • SLICE-derived strain markers of CRT response showed close agreement with CMR-TAG. • Future studies will focus on the prognostic value of SLICE in CRT candidates.
Schouver, Elie-Dan; Moceri, Pamela; Doyen, Denis; Tieulie, Nathalie; Queyrel, Viviane; Baudouy, Delphine; Cerboni, Pierre; Gibelin, Pierre; Leroy, Sylvie; Fuzibet, Jean-Gabriel; Ferrari, Emile
2017-01-15
Cardiac sarcoidosis (CS) is associated with high morbidity and sudden death. The absence of specific symptoms and lack of diagnostic gold standard technique is challenging. New imaging methods could improve the diagnosis of CS. The aim of our study was to assess the role of left ventricular (LV) longitudinal and circumferential strain as estimated by 2D speckle-tracking imaging in patients with diagnosed sarcoidosis without cardiac involvement according to the current guidelines. We investigated the prevalence of LV strain impairment in this population and assessed its relationship with clinical outcomes, composite of mortality, heart failure, arrhythmia and/or secondarily development of CS and cardiac device implantation. We performed a prospective case-control longitudinal study including 35 patients with diagnosed sarcoidosis and normal cardiac function as assessed by standard transthoracic echocardiography and 35 healthy age- and gender-matched controls. All patients underwent a comprehensive echocardiographic study. Mean age of patients was 47.9±14.8years old (22 women). Compared with controls, global LV longitudinal strain (LV GLS) was reduced in sarcoidosis patients: (-17.2±3.1 vs -21.3±1.5%, p<0.0001). Circumferential LV strain was preserved in patients compared to controls (-19.9±-4.3% vs -21.3±1.5%, p=0.12). Impaired LV GLS was significantly associated with clinical outcomes (HR 1.56; [1.16-2.11], p<0.01) on univariate analysis. Speckle-tracking echocardiography revealed decreased longitudinal LV strain in sarcoidosis patients that was associated with outcomes. LV GLS may represent an early marker of myocardial involvement in sarcoidosis patients that needs to be studied further. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Pan, Jie; Li, Lijun; Qian, Lie; Zhou, Wei; Tan, Jun; Zou, Le; Yang, Mingjie
2011-02-15
STUDY DESIGN.: Retrospective clinical data analysis. OBJECTIVE.: To investigate and verify our philosophy of spontaneous slip reduction following circumferential release via bilateral minimally invasive transforaminal lumbar interbody fusion (Mini-TLIF) for treatment of low-grade symptomatic isthmic spondylolisthesis. SUMMARY OF BACKGROUND DATA.: Symptomatic isthmic spondylolisthesis usually requires surgical intervention, and the most currently controversial focus is on method and degree of reduction; and Mini-TLIF is an attractive surgical procedure for isthmic spondylolisthesis. METHODS.: Between February 2004 and June 2008, 21 patients with low-grade isthmic spondylolisthesis underwent Mini-TLIF in our institute. Total resection of the scar around the pars interarticularis liberated the nerve roots, achieving posterior release as well. The disc was thoroughly resected, and the disc space was gradually distracted and thoroughly released with sequential disc shavers until rupture of anulus conjunct with anterior longitudinal ligament, accomplishing anterior release, so as to insert Cages. Because of circumferential release, the slipped vertebrae would tend to obtain spontaneous reduction, and with pedicle screw fixation, additional reduction would be achieved without any application of posterior translation force. Radiographs, Visual Analogue Scale, and Oswestry Disability Index were documented. All the cases were followed up for 10 to 26 months. RESULTS.: Slip percentage was reduced from 24.2% ± 6.9% to 10.5% ± 4.0%, and foraminal area percentage increased from 89.1% ± 3.0% to 93.6% ± 2.1%. Visual Analogue Scale and Oswestry Disability Index decreased from 7.8 ± 1.5 to 2.1 ± 1.1 and from 53.3 ± 16.2 to 17.0 ± 7.8, respectively. No neurologic complications were encountered. There were no signs of instrumentation failure. The fusion rate approached 100%. CONCLUSION.: Slip reduction is based on circumferential release. The procedure can be well performed
NASA Astrophysics Data System (ADS)
Roth, Austin; Coleman, Leslie; Sakakura, Kenichi; Ladich, Elena; Virmani, Renu
2015-03-01
An intra-luminal ultrasound catheter system (ReCor Medical's Paradise System) has been developed to provide circumferential denervation of the renal sympathetic nerves, while preserving the renal arterial intimal and medial layers, in order to treat hypertension. The Paradise System features a cylindrical non-focused ultrasound transducer centered within a balloon that circulates cooling fluid and that outputs a uniform circumferential energy pattern designed to ablate tissues located 1-6 mm from the arterial wall and protect tissues within 1 mm. RF power and cooling flow rate are controlled by the Paradise Generator which can energize transducers in the 8.5-9.5 MHz frequency range. Computer simulations and tissue-mimicking phantom models were used to develop the proper power, cooling flow rate and sonication duration settings to provide consistent tissue ablation for renal arteries ranging from 5-8 mm in diameter. The modulation of these three parameters allows for control over the near-field (border of lesion closest to arterial wall) and far-field (border of lesion farthest from arterial wall, consisting of the adventitial and peri-adventitial spaces) depths of the tissue lesion formed by the absorption of ultrasonic energy and conduction of heat. Porcine studies have confirmed the safety (protected intimal and medial layers) and effectiveness (ablation of 1-6 mm region) of the system and provided near-field and far-field depth data to correlate with bench and computer simulation models. The safety and effectiveness of the Paradise System, developed through computer model, bench and in vivo studies, has been demonstrated in human clinical studies.
Wang, Qiushuang; Huang, Dangsheng; Zhang, Liwei; Shen, Dong; Ouyang, Qiaohong; Duan, Zhongxiang; An, Xiuzhi; Zhang, Meiqing; Zhang, Chunhong; Yang, Feifei; Zhi, Guang
2015-10-01
To compare three-dimensional (3D) and two-dimensional (2D) speckle tracking echocardiography (STE) techniques in the assessment of left ventricular function and myocardial infarct size (MIS). Thirty-two patients diagnosed with ST elevation myocardial infarction and 18 healthy control patients underwent 2D echocardiography, 3D echocardiography, and single photon emission computed tomography (SPECT). 3D left ventricular global area strain (GAS), 2D and 3D global longitudinal strain (GLS), global radial strain (GRS) as well as global circumferential strain (GCS) were analyzed to correlate with myocardial infarct size detected by SPECT. 2D and 3D left ventricular ejection fraction (LVEF) as well as 2D and 3D wall motion score index (WMSI) also were measured using conventional echocardiography. The 2D-GLS values were significantly higher than that of 3D-GLS, while 2D-GCS and GRS were significantly lower than 3D-GCS and GRS, respectively. However, no significant differences in LVEF and WMSI could be observed between 2D and 3D echocardiography. Myocardial strain indices, LVEF, and WMSI using 2D and 3D echocardiography also had good correlations with MIS as measured by SPECT. ROC curve analysis showed that the 3D and 2D myocardial indices, LVEF, and WMSI could distinguish between small and large MIS, while 2D-GLS had the highest AUC. The 2D and 3D myocardial strain indices correlated well with MIS by SPECT. Among them, the 2D-GLS showed the highest diagnostic value, while 3D-GRS and GCS had better diagnostic value than 2D-GRS and GCS. © 2015, Wiley Periodicals, Inc.
Gulel, Okan; Akcay, Murat; Soylu, Korhan; Aksan, Gokhan; Yuksel, Serkan; Zengin, Halit; Meric, Murat; Sahin, Mahmut
2016-05-01
The coronary slow flow phenomenon (CSFP) is defined as a delayed distal vessel contrast opacification in the absence of obstructive epicardial coronary artery disease during coronary angiography. There is conflicting data in medical literature regarding the effects of CSFP on the left ventricular functions assessed by conventional echocardiography or tissue Doppler imaging. Therefore, we aimed to evaluate whether there is any abnormality in the myocardial deformation parameters (strain, strain rate (SR), rotation, twist) of the left ventricle obtained by speckle tracking echocardiography (STE) in patients with CSFP. Twenty patients with CSFP were included prospectively in the study. Another 20 patients with similar demographics and cardiovascular risk factors as well as normal coronary angiography were used as the control group. Two-dimensional echocardiographic images of the left ventricle from the apical long-axis, two-chamber, four-chamber, and parasternal short-axis views were used for STE analysis. The analysis of left ventricular circumferential deformation parameters showed that the averaged peak systolic strain, systolic SR, and early diastolic SR values were significantly lower in patients with CSFP (P = 0.009, P = 0.02, and P = 0.02, respectively). Among the left ventricular rotation and twist values, apical rotation was significantly lower in patients with CSFP (P = 0.02). Further, the mean thrombolysis in myocardial infarction frame count value was found to be negatively correlated with the averaged peak circumferential early diastolic SR (r = -0.35, P = 0.03). It was positively correlated with the averaged peak circumferential systolic strain (r = 0.47, P = 0.003) and circumferential systolic SR (r = 0.46, P = 0.005). Coronary slow flow phenomenon leads to significant alterations in the myocardial deformation parameters of the left ventricle as assessed by STE. Specifically, circumferential deformation parameters are affected in CSFP patients. © 2015
Enhanced heat transfer with full circumferential ribs in helical pipe
NASA Astrophysics Data System (ADS)
Chang, S. W.; Su, L. M.; Yang, T. L.
2002-08-01
This paper describes an experimental study of heat transfers in the smooth-walled and rib-roughened helical pipes with reference to the design of enhanced cooling passages in the cylinder head and liner of a marine propulsive diesel engine. The manner in which the repeated ribs modify the forced heat convection in the helical pipe is considered for the case where the flow is turbulent upon entering the coil but laminar in further downstream. A selection of experimental results illustrates the individual and interactive effects of Dean vortices and rib-flows on heat transfer along the inner and outer helixes of coils. The experimental-based observations reveal that the centrifugal force modifies the heat transfer in a manner to generate circumferential heat transfer variation with better cooling performance on the outer edge relative to its inner counterpart even with the agitated flow field caused by the repeated ribs. Heat transfer augmentation factor in the range of 1.3 - 3 times of the smooth-walled level is achieved using the present ribbing geometry. A set of empirical correlations based on the experimental data has been developed to permit the evaluation of heat transfers along the inner and outer helixes of the smooth-walled and rib-roughened helical pipes.
Garner, Alan A; Hsu, Jeremy; McShane, Anne; Sroor, Adam
Increased fracture displacement has previously been described with the application of pelvic circumferential compression devices (PCCDs) in patients with lateral compression-type pelvic fracture. We describe the first reported case of hemodynamic deterioration temporally associated with the prehospital application of a PCCD in a patient with a complex acetabular fracture with medial displacement of the femoral head. Active hemorrhage from a site adjacent to the acetabular fracture was subsequently demonstrated on angiography. Caution in the application of PCCDs to patients with lateral compression-type fractures is warranted. Copyright © 2017 Air Medical Journal Associates. All rights reserved.
Monitoring elbow isometric contraction by novel wearable fabric sensing device
NASA Astrophysics Data System (ADS)
Wang, Xi; Tao, Xiaoming; So, Raymond C. H.; Shu, Lin; Yang, Bao; Li, Ying
2016-12-01
Fabric-based wearable technology is highly desirable in sports, as it is light, flexible, soft, and comfortable with little interference to normal sport activities. It can provide accurate information on the in situ deformation of muscles in a continuous and wireless manner. During elbow flexion in isometric contraction, upper arm circumference increases with the contraction of elbow flexors, and it is possible to monitor the muscles’ contraction by limb circumferential strains. This paper presents a new wireless wearable anthropometric monitoring device made from fabric strain sensors for the human upper arm. The materials, structural design and calibration of the device are presented. Using an isokinetic testing system (Biodex3®) and the fabric monitoring device simultaneously, in situ measurements were carried out on elbow flexors in isometric contraction mode with ten subjects for a set of positions. Correlations between the measured values of limb circumferential strain and normalized torque were examined, and a linear relationship was found during isometric contraction. The average correlation coefficient between them is 0.938 ± 0.050. This wearable anthropometric device thus provides a useful index, the limb circumferential strain, for upper arm muscle contraction in isometric mode.
Development of circumferential seal for helicopter transmissions: Results of bench and flight tests
NASA Technical Reports Server (NTRS)
Strom, T. N.; Ludwig, L. P.
1975-01-01
A modified circumferential segmented ring seal was designed for direct replacement of a helicopter transmission elastomeric lip seal operating on a shaft diameter of 13.91 centimeters (5.481 in.) at sliding velocities to 52.48 m/sec (10 330 ft/min). The modifications involved the garter spring tension, shaft roundness, seal housing flatness, and pumping grooves to inhibit leakage. Operation of the seals in bench tests under simulated helicopter transmission conditions revealed that the seal leakage rate was within acceptable limits and that the wear rate was negligible. The low leakage and wear rates were confirmed in flight tests of 600 and 175 hours (sliding speed, 48.11 m/sec (9470 ft/min)). An additional 200 hours of air worthiness qualification testing (aircraft tie down) demonstrated that the seal can operate at the advanced sliding conditions of 52.48 m/sec (10 330 ft/min).
Lin, Kai; Collins, Jeremy D; Chowdhary, Varun; Markl, Michael; Carr, James C
2016-10-01
To test the performance of HDA in characterizing left ventricular (LV) function and regional myocardial motion patterns in the context of cardiomyopathy based on cine cardiovascular magnetic resonance (CMR). Following the approval of the institutional review board (IRB), standard cine images of 45 subjects, including 15 healthy volunteers, 15 patients with hypertrophic cardiomyopathy (HCM) and 15 patients with dilated cardiomyopathy (DCM) were retrospectively analyzed using HDA. The variations of LV ejection fraction (LVEF), LV mass (LVM), and regional myocardial motion indices, including radial (Drr), circumferential (Dcc) displacement, radial (Vrr) and circumferential (Vcc) velocity, radial (Err), circumferential (Ecc) and shear (Ess) strain and radial (SRr) and circumferential (SRc) strain rate, were calculated and compared among subject groups. Inter-study reproducibility of HDA-derived myocardial motion indices were tested on 15 volunteers by using intra-class correlation coefficient (ICC) and coefficient of variation (CoV). HDA identified significant differences in cardiac function and motion indices between subject groups. DCM patients had significantly lower LVEF (33.5±9.65%), LVM (105.88±21.93g), peak Drr (0.29±0.11cm), Vrr-sys (2.14±0.72cm/s), Err (0.17±0.08), Ecc (-0.08±0.03), SRr-sys (0.91±0.44s(-1)) and SRc-sys (-0.64±0.27s(-1)) compared to the other two groups. HCM patients demonstrated increased LVM (171.69±34.19) and lower peak Vcc-dia (0.78±0.30cm/s) than other subjects. Good inter-study reproducibility was found for all HDA-derived myocardial indices in healthy volunteers (ICC=0.664-0.942, CoV=15.1%-37.1%). Without the need for operator interaction, HDA is a reproducible method for the automated characterization of global and regional LV function in the context of cardiomyopathy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Holmes, Anthony A; Taub, Cynthia C; Garcia, Mario J; Shan, Jian; Slovut, David P
2017-02-01
Patients with paradoxical low-flow severe aortic stenosis (PLF-AS) reportedly have higher left ventricular hydraulic load and more systolic strain dysfunction than patients with normal-flow aortic stenosis. This study investigates the relationship of systolic loading and strain to PLF-AS to further define its pathophysiology. One hundred and twenty patients (age 79 ± 12 years, 37% men) with an indexed aortic valve area (AVAi) of 0.6 cm/m or less and an ejection fraction of 50% or higher were divided into two groups based on indexed stroke volume (SVi): PLF-AS, SVi ≤ 35 ml/m, N = 46; normal-flow aortic stenosis, SVi > 35 ml/m, N = 74). Valvular and arterial load were assessed using multiple measurements, and strain was assessed using speckle-tracking echocardiography. Patients with PLF-AS were found to have more valvular load (lower AVAi, P = 0.028; lower energy loss coefficient, P = 0.001), more arterial load [decreased arterial compliance and increased systemic vascular resistance (SVR), both P < 0.001] and more total hydraulic load [increased valvuloarterial impedance (Zva), P < 0.001]. Transvalvular gradients and arterial pressures were similar. Longitudinal strain was lower in PLF-AS (P < 0.001), but circumferential and rotation strains were similar. On adjusted regression, AVAi, SVR and longitudinal strain were associated with PLF-AS [odds ratio (OR) = 1.34, P = 0.043; OR = 1.31, P = 0.004; OR = 1.34, P = 0.011, respectively]. When SVR and AVAi were replaced with Zva, longitudinal strain and Zva (OR = 1.38, P = 0.015; OR = 1.33, P < 0.001 for both, respectively) were associated with PLF-AS. Increased hydraulic load, from more severe valvular stenosis and increased vascular resistance, and longitudinal strain impairment are associated with PLF-AS and their interplay is likely fundamental to its pathophysiology.
Mvubu, Nontobeko Eunice; Pillay, Balakrishna; Gamieldien, Junaid; Bishai, William; Pillay, Manormoney
2016-12-01
Although pulmonary epithelial cells are integral to innate and adaptive immune responses during Mycobacterium tuberculosis infection, global transcriptomic changes in these cells remain largely unknown. Changes in gene expression induced in pulmonary epithelial cells infected with M. tuberculosis F15/LAM4/KZN, F11, F28, Beijing and Unique genotypes were investigated by RNA sequencing (RNA-Seq). The Illumina HiSeq 2000 platform generated 50 bp reads that were mapped to the human genome (Hg19) using Tophat (2.0.10). Differential gene expression induced by the different strains in infected relative to the uninfected cells was quantified and compared using Cufflinks (2.1.0) and MeV (4.0.9), respectively. Gene expression varied among the strains with the total number of genes as follows: F15/LAM4/KZN (1187), Beijing (1252), F11 (1639), F28 (870), Unique (886) and H37Rv (1179). A subset of 292 genes was commonly induced by all strains, where 52 genes were down-regulated while 240 genes were up-regulated. Differentially expressed genes were compared among the strains and the number of induced strain-specific gene signatures were as follows: F15/LAM4/KZN (138), Beijing (52), F11 (255), F28 (55), Unique (186) and H37Rv (125). Strain-specific molecular gene signatures associated with functional pathways were observed only for the Unique and H37Rv strains while certain biological functions may be associated with other strain signatures. This study demonstrated that strains of M. tuberculosis induce differential gene expression and strain-specific molecular signatures in pulmonary epithelial cells. Specific signatures induced by clinical strains of M. tuberculosis can be further explored for novel host-associated biomarkers and adjunctive immunotherapies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Wall strains produced by waves in water filled latex tubes. Part 1: Tethered tubes
NASA Astrophysics Data System (ADS)
Gerrard, J. H.
1992-05-01
A progress report on measurements of wall strain is presented. The experimental aim is to produce data with which to compare the results of numerical analysis of pulsatile flow in a deformable tube. The computation is a difficult job requiring the solution of the wall and fluid equations and matching them at the interface which moves. The simplest arrangement of a straight distensible tube attached to a rigid tube of the same internal diameter in which a piston starts from rest was consequently chosen. The rubber tube is of finite length and closed and fixed at the far end. Two forms of motion are examined, sinusoidal motion from rest and impulsive motion in which the piston moves a short distance and stops. The simpler case considered is a tethered tube which only executes radial motion; in the second case the horizontal tube is suspended by cotton threads so that it is free to move longitudinally as well. Measurements of the longitudinal and circumferential strains as a function of distance along the tube were made. The measurements were made at low and high frequency and with short and long tubes. With long tubes the end effect can be investigated. The treatment of shorter tubes by numerical analysis present less of a storage problem.
García-Ríos, Estéfani; López-Malo, María; Guillamón, José Manuel
2014-12-03
The wine industry needs better-adapted yeasts to grow at low temperature because it is interested in fermenting at low temperature to improve wine aroma. Elucidating the response to cold in Saccharomyces cerevisiae is of paramount importance for the selection or genetic improvement of wine strains. We followed a global approach by comparing transcriptomic, proteomic and genomic changes in two commercial wine strains, which showed clear differences in their growth and fermentation capacity at low temperature. These strains were selected according to the maximum growth rate in a synthetic grape must during miniaturized batch cultures at different temperatures. The fitness differences of the selected strains were corroborated by directly competing during fermentations at optimum and low temperatures. The up-regulation of the genes of the sulfur assimilation pathway and glutathione biosynthesis suggested a crucial role in better performance at low temperature. The presence of some metabolites of these pathways, such as S-Adenosilmethionine (SAM) and glutathione, counteracted the differences in growth rate at low temperature in both strains. Generally, the proteomic and genomic changes observed in both strains also supported the importance of these metabolic pathways in adaptation at low temperature. This work reveals a novel role of the sulfur assimilation pathway in adaptation at low temperature. We propose that a greater activation of this metabolic route enhances the synthesis of key metabolites, such as glutathione, whose protective effects can contribute to improve the fermentation process.
A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor.
Zhang, Huayu; Xie, Fengqin; Cao, Maoyong; Zhong, Mingming
2017-07-01
To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA) sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor), magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.
Effects of the Antimutagens Vanillin and Cinnamaldehyde on Spontaneous Mutation in E. coli lacI Strains and on Global Gene Epression in Salmonella TAlO4 and Human HepG2 Cells
In previous work we have shown that vanillin (VAN) and cinnamaldehyde (CIN) are dietary antimutag...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, Jon M.; Yang, Xiaohua; Luft, Benjamin J.
2005-04-01
The Borrelia burgdorferi spirochete is the causative agent of Lyme disease, the most common tick-borne disease in the United States. It has been studied extensively to help understand its pathogenicity of infection and how it can persist in different mammalian hosts. We report the proteomic analysis of the archetype B. burgdorferi B31 strain and two other strains (ND40, and JD-1) having different Borrelia pathotypes using strong cation exchange fractionation of proteolytic peptides followed by high-resolution, reversed phase capillary liquid chromatography coupled with ion trap tandem mass spectrometric (LC-MS/MS) analysis. Protein identification was facilitated by the availability of the complete B31more » genome sequence. A total of 665 Borrelia proteins were identified representing ~38 % coverage of the theoretical B31 proteome. A significant overlap was observed between the identified proteins in direct comparisons between any two strains (>72%), but distinct differences were observed among identified hypothetical and outer membrane proteins of the three strains. Such a concurrent proteomic overview of three Borrelia strains based upon only the B31 genome sequence is shown to provide significant insights into the presence or absence of specific proteins and a broad overall comparison among strains.« less
NASA Astrophysics Data System (ADS)
Tan, Yayun; Zhang, He; Zha, Bingting
2017-09-01
Underwater target detection and ranging in seawater are of interest in unmanned underwater vehicles. This study presents an underwater detection system that synchronously scans a collimated laser beam and a narrow field of view to circumferentially detect an underwater target. Hybrid methods of range-gated and variable step-size least mean squares (VSS-LMS) adaptive filter are proposed to suppress water backscattering. The range-gated receiver eliminates the backscattering of near-field water. The VSS-LMS filter extracts the target echo in the remaining backscattering and the constant fraction discriminator timing method is used to improve ranging accuracy. The optimal constant fraction is selected by analysing the jitter noise and slope of the target echo. The prototype of the underwater detection system is constructed and tested in coastal seawater, then the effectiveness of backscattering suppression and high-ranging accuracy is verified through experimental results and analysis discussed in this paper.
Liang, Chen; Ma, Yun; Gao, Can; Zhang, Jianhong; Yang, Min; Chen, Gen; Fu, Shan; Zhu, Tiangang
2017-02-01
The aim of this study was to investigate the change in myocardial strain in swimming athletes before and after high-intensity exercise using two-dimensional strain echocardiography (2DSE) technology. To assess whether the local and overall myocardial function and myocardial injury are accurately measured using 2DSE technology, 15 swimming athletes were selected as research objects. We applied 2DSE technology to track the 2D ultrasound images of the apical four chambers, the apical two chambers, and the apical long axis before and after high-intensity, increasing-load exercise. We recorded indices such as the left ventricular global strain (GS) and the left ventricular segmental wall longitudinal peak systolic strain (PS) in 18 systoles and analyzed the myocardial strain change before and after exercise. After high-intensity exercise, the overall myocardial strain decreased, especially the strain of the posterior wall, posterior divider, lateral wall, lower wall, and the basal and middle segments of the anterior wall. The influence of exercise on myocardial strain was greater on the basal and middle segments than on the apical segment. One-time intensive exercise negatively affected the myocardial muscle. Myocardial muscles in the apical segment and the myocardial wall were more sensitive to intensive exercise. The 2DSE technology can precisely position the motion-sensitive areas and help locate myocardial injury. © 2017, Wiley Periodicals, Inc.
Borehole observations of continuous strain and fluid pressure: Chapter 9
Roeloffs, Evelyn A.; Linde, A.T.
2007-01-01
Strain is expansion, contraction, or distortion of the volcanic edifice and surrounding crust. As a result of magma movement, volcanoes may undergo enormous strain prior to and during eruption. Global Positioning System (GPS) observations can in principle be used to determine strain by taking the difference between two nearby observations and dividing by the distance between them. Two GPS stations 1 km apart, each providing displacement information accurate to the nearest millimeter, could detect strain as small as 2 mm km-1, or 2 × 10-6. It is possible, however, to measure strains at least three orders of magnitude smaller using borehole strainmeters. In fact, it is even possible to measure strains as small as 10-8 using observations of groundwater levels in boreholes.
Binnetoğlu, Fatih Köksal; Babaoğlu, Kadir; Altun, Gürkan; Kayabey, Özlem
2014-01-01
Whether the hypertrophy found in the hearts of athletes is physiologic or a risk factor for the progression of pathologic hypertrophy remains controversial. The diastolic and systolic functions of athletes with left ventricular (LV) hypertrophy usually are normal when measured by conventional methods. More precise assessment of global and regional myocardial function may be possible using a newly developed two-dimensional (2D) strain echocardiographic method. This study evaluated the effects that different types of sports have on the hearts of children and adolescents and compared the results of 2D strain and strain-rate echocardiographic techniques with conventional methods. Athletes from clubs for five different sports (basketball, swimming, football, wrestling, and tennis) who had practiced regularly at least 3 h per week during at least the previous 2 years were included in the study. The control group consisted of sedentary children and adolescents with no known cardiac or systemic diseases (n = 25). The athletes were grouped according to the type of exercise: dynamic (football, tennis), static (wrestling), or static and dynamic (basketball, swimming). Shortening fraction and ejection fraction values were within normal limits for the athletes in all the sports disciplines. Across all 140 athletes, LV geometry was normal in 58 athletes (41.4 %), whereas 22 athletes (15.7 %) had concentric remodeling, 20 (14.3 %) had concentric hypertrophy, and 40 (28.6 %) had eccentric hypertrophy. Global LV longitudinal strain values obtained from the average of apical four-, two-, and three-chamber global strain values were significantly lower for the basketball players than for all the other groups (p < 0.001).
Gietelink, Lieke; Henneman, Daniel; van Leersum, Nicoline J; de Noo, Mirre; Manusama, Eric; Tanis, Pieter J; Tollenaar, Rob A E M; Wouters, Michel W J M
2016-04-01
This population-based study evaluates the association between hospital volume and CRM (circumferential resection margin) involvement, adjusted for other confounders, in rectal cancer surgery. A low hospital volume (<20 cases/year) was independently associated with a higher risk of CRM involvement (odds ratio=1.54; 95% CI: 1.12-2.11). To evaluate the association between hospital volume and CRM (circumferential resection margin) involvement in rectal cancer surgery. To guarantee the quality of surgical treatment of rectal cancer, the Association of Surgeons of the Netherlands has stated a minimal annual volume standard of 20 procedures per hospital. The influence of hospital volume has been examined for different outcome variables in rectal cancer surgery. Its influence on the pathological outcome (CRM) however remains unclear. As long-term outcomes are best predicted by the CRM status, this parameter is of essential importance in the debate on the justification of minimal volume standards in rectal cancer surgery. Data from the Dutch Surgical Colorectal Audit (2011-2012) were used. Hospital volume was divided into 3 groups, and baseline characteristics were described. The influence of hospital volume on CRM involvement was analyzed, in a multivariate model, between low- and high-volume hospitals, according to the minimal volume standards. This study included 5161 patients. CRM was recorded in 86% of patients. CRM involvement was 11% in low-volume group versus 7.7% and 7.9% in the medium- and high-volume group (P≤0.001). After adjustment for relevant confounders, the influence of hospital volume on CRM involvement was still significant odds ratio (OR) = 1.54; 95% CI: 1.12-2.11). The outcomes of this pooled analysis support minimal volume standards in rectal cancer surgery. Low hospital volume was independently associated with a higher risk of CRM involvement (OR = 1.54; 95% CI: 1.12-2.11).
Effect of strain rate and dislocation density on the twinning behavior in Tantalum
Florando, Jeffrey N.; El-Dasher, Bassem S.; Chen, Changqiang; ...
2016-04-28
The conditions which affect twinning in tantalum have been investigated across a range of strain rates and initial dislocation densities. Tantalum samples were subjected to a range of strain rates, from 10 –4/s to 10 3/s under uniaxial stress conditions, and under laser-induced shock-loading conditions. In this study, twinning was observed at 77K at strain rates from 1/s to 103/s, and during laser-induced shock experiments. The effect of the initial dislocation density, which was imparted by deforming the material to different amounts of pre-strain, was also studied, and it was shown that twinning is suppressed after a given amount ofmore » pre-strain, even as the global stress continues to increase. These results indicate that the conditions for twinning cannot be represented solely by a critical global stress value, but are also dependent on the evolution of the dislocation density. Additionally, the analysis shows that if twinning is initiated, the nucleated twins may continue to grow as a function of strain, even as the dislocation density continues to increase.« less
Al-Khalid, Hamad; Alaskari, Ayman; Oraby, Samy
2011-01-01
Hardness homogeneity of the commonly used structural ferrous and nonferrous engineering materials is of vital importance in the design stage, therefore, reliable information regarding material properties homogeneity should be validated and any deviation should be addressed. In the current study the hardness variation, over wide spectrum radial locations of some ferrous and nonferrous structural engineering materials, was investigated. Measurements were performed over both faces (cross-section) of each stock bar according to a pre-specified stratified design, ensuring the coverage of the entire area both in radial and circumferential directions. Additionally the credibility of the apparatus and measuring procedures were examined through a statistically based calibration process of the hardness reference block. Statistical and response surface graphical analysis are used to examine the nature, adequacy and significance of the measured hardness values. Calibration of the apparatus reference block proved the reliability of the measuring system, where no strong evidence was found against the stochastic nature of hardness measures over the various stratified locations. Also, outlier elimination procedures were proved to be beneficial only at fewer measured points. Hardness measurements showed a dispersion domain that is within the acceptable confidence interval. For AISI 4140 and AISI 1020 steels, hardness is found to have a slight decrease trend as the diameter is reduced, while an opposite behavior is observed for AA 6082 aluminum alloy. However, no definite significant behavior was noticed regarding the effect of the sector sequence (circumferential direction). PMID:28817030
Al-Khalid, Hamad; Alaskari, Ayman; Oraby, Samy
2011-12-23
Hardness homogeneity of the commonly used structural ferrous and nonferrous engineering materials is of vital importance in the design stage, therefore, reliable information regarding material properties homogeneity should be validated and any deviation should be addressed. In the current study the hardness variation, over wide spectrum radial locations of some ferrous and nonferrous structural engineering materials, was investigated. Measurements were performed over both faces (cross-section) of each stock bar according to a pre-specified stratified design, ensuring the coverage of the entire area both in radial and circumferential directions. Additionally the credibility of the apparatus and measuring procedures were examined through a statistically based calibration process of the hardness reference block. Statistical and response surface graphical analysis are used to examine the nature, adequacy and significance of the measured hardness values. Calibration of the apparatus reference block proved the reliability of the measuring system, where no strong evidence was found against the stochastic nature of hardness measures over the various stratified locations. Also, outlier elimination procedures were proved to be beneficial only at fewer measured points. Hardness measurements showed a dispersion domain that is within the acceptable confidence interval. For AISI 4140 and AISI 1020 steels, hardness is found to have a slight decrease trend as the diameter is reduced, while an opposite behavior is observed for AA 6082 aluminum alloy. However, no definite significant behavior was noticed regarding the effect of the sector sequence (circumferential direction).
NASA Astrophysics Data System (ADS)
Qin, Renyao; Duan, Zhaoling; He, Guo
2013-10-01
The large circumferential multipass dissimilar weld between 20MND5 steel and Z2CND18-12NS stainless steel welded with FM52 filler material was investigated in terms of the diluted composition, the grain boundary precipitation, and the ductility-dip cracking (DDC) susceptibility of the weld. The diluted composition of the weld is composed of 37 to 47 pct Ni, 21 to 24 pct Cr, and 28 to 40 pct Fe, which are inhomogeneous along the depth and over the width of the deep weld. The carbon content has a distribution in the region of the surface weld from a high level (~0.20 pct) in the zone near 20MND5 steel to a normal level (~0.03 pct) in the zone near Z2CND18-12NS stainless steel. The carbon distribution is corresponding to the grain boundary carbides. The minimum threshold strains for DDC occur in the temperature range of 1223 K to 1323 K (950 °C to 1050 °C), which are 0.5, 0.35, and 0.4 pct for the root weld, middle region, and the surface weld, respectively. The dissimilar weld has the largest susceptibility to the DDC compared to the filler metal 52 and the Inconel 690.
NASA Astrophysics Data System (ADS)
Lv, Jiuming; Hu, Fangyi; Cao, Quoc Dinh; Yuan, Renshu; Wu, Zhilin; Cai, Hongming; Zhao, Lei; Zhang, Xinping
2017-03-01
Hydrostatic extrusion integrated with circular equal channel angular pressing has been previously proposed for fabricating AZ80 magnesium alloy tubes as a method to obtain high-strength tubes for industrial applications. In order to axial tensile strength, circumferential mechanical properties are also important for tubular structures. The tensile properties of AZ80 tubes have been previously studied; however, the circumferential properties have not been examined. In this work, circumferential mechanical properties of these tubes were studied using lateral compression tests. An analytical model is proposed to evaluate the circumferential elongation, which is in good agreement with finite element results. The effects of the extrusion ratio and conical mandrel angle on the circumferential elongation and lateral compression strength are discussed. The strain distribution in the sample during lateral compression testing was found to be inhomogeneous, and cracks initially appeared on the inner surface of the sample vertex. The circumferential elongation and lateral compression strength increased with the extrusion ratio and conical mandrel angle. The anisotropy of the tube's mechanical properties was insignificant when geometric effects were ignored.
Spacecraft Dynamic Characterization by Strain Energies Method
NASA Astrophysics Data System (ADS)
Bretagne, J.-M.; Fragnito, M.; Massier, S.
2002-01-01
In the last years the significant increase in satellite broadcasting demand, with the wide band communication dawn, has given a great impulse to the telecommunication satellite market. The big demand is translated from operators (such as SES/Astra, Eutelsat, Intelsat, Inmarsat, EuroSkyWay etc.) in an increase of orders of telecom satellite to the world industrials. The largest part of these telecom satellite orders consists of Geostationary platforms which grow more and more in mass (over 5 tons) due to an ever longer demanded lifetime (up to 20 years), and become more complex due to the need of implementing an ever larger number of repeaters, antenna reflectors and feeds, etc... In this frame, the mechanical design and verification of these large spacecraft become difficult and ambitious at the same time, driven by the dry mass limitation objective. By the Finite Element Method (FEM), and on the basis of the telecom satellite heritage of a world leader constructor such as Alcatel Space Industries it is nowadays possible to model these spacecraft in a realistic and confident way in order to identify the main global dynamic aspects such as mode shapes, mass participation and/or dynamic responses. But on the other hand, one of the main aims consists in identifying soon in a program the most critical aspects of the system behavior in the launch dynamic environment, such as possible dynamic coupling between the different subsystems and secondary structures of the spacecraft (large deployable reflectors, thrusters, etc.). To this aim a numerical method has been developed in the frame of the Alcatel SPACEBUS family program, using MSC/Nastran capabilities and it is presented in this paper. The method is based on Spacecraft sub-structuring and strain energy calculation. The method mainly consists of two steps : 1) subsystem modal strain energy ratio (with respect to the global strain energy); 2) subsystem strain energy calculation for each mode according to the base driven
Yang, Jian; Zhao, Jingbo; Liao, Donghua; Gregersen, Hans
2006-01-01
Passive biomechanical properties in term of the stress-strain relationship and the shear modulus were studied in separated muscle layer and mucosa-submucosa layer in the oesophagus of normal and STZ (streptozotocin)-induced diabetic rats. The mucosa-submucosa and muscle layers were separated using microsurgery and studied in vitro using a self-developed test machine. Stepwise elongation and inflation plus continuous twist were applied to the samples. A constitutive equation based on a strain energy function was used for the stress-strain analysis. Five material constants were obtained for both layers. The mucosa-submucosa layer was significantly stiffer than the muscle layer in longitudinal, circumferential and circumferential-longitudinal shear direction. The mechanical constants of the oesophagus show that the oesophageal wall was anisotropic, the stiffness in the longitudinal direction was higher than in the circumferential direction in the intact oesophagus (P < 0.001) and in the muscle layer (P < 0.05). Diabetes-induced pronounced increase in the outer perimeter, inner perimeter and lumen area in both the muscle and mucosa-submucosa layer. The growth of the mucosa-submucosa layer (P < 0.001) was more pronounced than the muscle layer (P < 0.05). Furthermore, the circumferential stiffness of the mucosa-submucosa layer increased 28 days after STZ treatment. In conclusion, the oesophagus is a non-homogeneous anisotropic tube. Thus, the mechanical properties differed between layers as well as in different directions. Morphological and biomechanical remodelling is prominent in the diabetic oesophagus.
Curiale, Ariel H; Vegas-Sánchez-Ferrero, Gonzalo; Bosch, Johan G; Aja-Fernández, Santiago
2015-08-01
accurate method to measure the motion and strain with an average median motion error of 0.42 mm and a median strain error of 2.0 ± 0.9%, 2.1 ± 1.3% and 7.1 ± 4.9% for circumferential, longitudinal and radial strain respectively. It also showed its capability to identify abnormal segments with reduced cardiac function and timing differences for the dyssynchrony cases. These results indicate that the proposed diffeomorphic speckle tracking method provides robust and accurate motion and strain estimation. Copyright © 2015. Published by Elsevier B.V.
Kuruvilla, Sujith; Janardhanan, Rajesh; Antkowiak, Patrick; Keeley, Ellen C; Adenaw, Nebiyu; Brooks, Jeremy; Epstein, Frederick H; Kramer, Christopher M; Salerno, Michael
2015-02-01
The goal of this study was to assess the relationship among extracellular volume (ECV), native T1, and systolic strain in hypertensive patients with left ventricular hypertrophy (HTN LVH), hypertensive patients without LVH (HTN non-LVH), and normotensive controls. Diffuse myocardial fibrosis in HTN LVH patients, as reflected by increased ECV and native T1, may be an underlying mechanism contributing to increased cardiovascular risk compared with HTN non-LVH subjects and controls. Furthermore, increased diffuse fibrosis in HTN LVH subjects may be associated with reduced peak systolic and early diastolic strain rate compared with the other 2 groups. T1 mapping was performed in 20 HTN LVH (mean age, 55 ± 11 years), 23 HTN non-LVH (mean age, 61 ± 12 years), and 22 control subjects (mean age, 54 ± 7 years) on a Siemens 1.5-T Avanto (Siemens Healthcare, Erlangen, Germany) using a previously validated modified look-locker inversion-recovery pulse sequence. T1 was measured pre-contrast and 10, 15, and 20 min after injection of 0.15 mmol/kg gadopentetate dimeglumine, and the mean ECV and native T1 were determined for each subject. Measurement of circumferential strain parameters were performed using cine displacement encoding with stimulated echoes. HTN LVH subjects had higher native T1 compared with controls (p < 0.05). HTN LVH subjects had higher ECV compared with HTN non-LVH subjects and controls (p < 0.05). Peak systolic circumferential strain and early diastolic strain rates were reduced in HTN LVH subjects compared with HTN non-LVH subjects and controls (p < 0.05). Increased levels of ECV and native T1 were associated with reduced peak systolic and early diastolic circumferential strain rate across all subjects. HTN LVH patients had higher ECV, longer native T1 and associated reduction in peak systolic circumferential strain, and early diastolic strain rate compared with HTN non-LVH and control subjects. Measurement of ECV and native T1 provide a noninvasive
A wide extent of inter-strain diversity in virulent and vaccine strains of alphaherpesviruses.
Szpara, Moriah L; Tafuri, Yolanda R; Parsons, Lance; Shamim, S Rafi; Verstrepen, Kevin J; Legendre, Matthieu; Enquist, L W
2011-10-01
Alphaherpesviruses are widespread in the human population, and include herpes simplex virus 1 (HSV-1) and 2, and varicella zoster virus (VZV). These viral pathogens cause epithelial lesions, and then infect the nervous system to cause lifelong latency, reactivation, and spread. A related veterinary herpesvirus, pseudorabies (PRV), causes similar disease in livestock that result in significant economic losses. Vaccines developed for VZV and PRV serve as useful models for the development of an HSV-1 vaccine. We present full genome sequence comparisons of the PRV vaccine strain Bartha, and two virulent PRV isolates, Kaplan and Becker. These genome sequences were determined by high-throughput sequencing and assembly, and present new insights into the attenuation of a mammalian alphaherpesvirus vaccine strain. We find many previously unknown coding differences between PRV Bartha and the virulent strains, including changes to the fusion proteins gH and gB, and over forty other viral proteins. Inter-strain variation in PRV protein sequences is much closer to levels previously observed for HSV-1 than for the highly stable VZV proteome. Almost 20% of the PRV genome contains tandem short sequence repeats (SSRs), a class of nucleic acids motifs whose length-variation has been associated with changes in DNA binding site efficiency, transcriptional regulation, and protein interactions. We find SSRs throughout the herpesvirus family, and provide the first global characterization of SSRs in viruses, both within and between strains. We find SSR length variation between different isolates of PRV and HSV-1, which may provide a new mechanism for phenotypic variation between strains. Finally, we detected a small number of polymorphic bases within each plaque-purified PRV strain, and we characterize the effect of passage and plaque-purification on these polymorphisms. These data add to growing evidence that even plaque-purified stocks of stable DNA viruses exhibit limited sequence
NASA Technical Reports Server (NTRS)
Delale, F.; Erdogan, F.
1977-01-01
The problem of a cylindrical shell containing a circumferential through crack is considered by taking into account the effect of transverse shear deformations. The formulation is given for a specially orthotropic material within the confines of a linearized shallow shell theory. The particular theory used permits the consideration of all five boundary conditions regarding moment and stress resultants on the crack surface. Consequently, aside from multiplicative constants representing the stress intensity factors, the membrane and bending components of the asymptotic stress fields near the crack tip are found to be identical. The stress intensity factors are calculated separately for a cylinder under a uniform membrane load, and that under a uniform bending moment. Sample results showing the nature of the out-of-plane crack surface displacement and the effect of the Poisson's ratio are presented.
Viscoelastic/damage modeling of filament-wound spherical pressure vessels
NASA Technical Reports Server (NTRS)
Hackett, Robert M.; Dozier, Jan D.
1987-01-01
A model of the viscoelastic/damage response of a filament-wound spherical vessel used for long-term pressure containment is developed. The matrix material of the composite system is assumed to be linearly viscoelastic. Internal accumulated damage based upon a quadratic relationship between transverse modulus and maximum circumferential strain is postulated. The resulting nonlinear problem is solved by an iterative routine. The elastic-viscoelastic correspondence is employed to produce, in the Laplace domain, the associated elastic solution for the maximum circumferential strain which is inverted by the method of collocation to yield the time-dependent solution. Results obtained with the model are compared to experimental observations.
Bansal, Sonia; Mandalapu, Sai; Aeppli, Céline; Qu, Feini; Szczesny, Spencer E; Mauck, Robert L; Zgonis, Miltiadis H
2017-07-01
The meniscus is comprised of circumferentially aligned fibers that resist the tensile forces within the meniscus (i.e., hoop stress) that develop during loading of the knee. Although these circumferential fibers are severed by radial meniscal tears, tibial contact stresses do not increase until the tear reaches ∼90% of the meniscus width, suggesting that the severed circumferential fibers still bear load and maintain the mechanical functionality of the meniscus. Recent data demonstrates that the interfibrillar matrix can transfer strain energy to disconnected fibrils in tendon fascicles. In the meniscus, interdigitating radial tie fibers, which function to stabilize and bind the circumferential fibers together, are hypothesized to function in a similar manner by transmitting load to severed circumferential fibers near a radial tear. To test this hypothesis, we developed an engineered fibrous analog of the knee meniscus using poly(ε-caprolactone) to create aligned scaffolds with variable amounts of non-aligned elements embedded within the scaffold. We show that the tensile properties of these scaffolds are a function of the ratio of aligned to non-aligned elements, and change in a predictable fashion following a simple mixture model. When measuring the loss of mechanical function in scaffolds with a radial tear, compared to intact scaffolds, the decrease in apparent linear modulus was reduced in scaffolds containing non-aligned layers compared to purely aligned scaffolds. Increased strains in areas adjacent to the defect were also noted in composite scaffolds. These findings indicate that non-aligned (disorganized) elements interspersed within an aligned network can improve overall mechanical function by promoting strain transfer to nearby disconnected fibers. This finding supports the notion that radial tie fibers may similarly promote tear tolerance in the knee meniscus, and will direct changes in clinical practice and provide guidance for tissue engineering
Tarascio, Michela; Leo, Laura Anna; Klersy, Catherine; Murzilli, Romina; Moccetti, Tiziano; Faletra, Francesco Fulvio
2017-07-01
Identification of the extent of scar transmurality in chronic ischemic heart disease is important because it correlates with viability. The aim of this retrospective study was to evaluate whether layer-specific two-dimensional speckle-tracking echocardiography allows distinction of scar presence and transmurality. A total of 70 subjects, 49 with chronic ischemic cardiomyopathy and 21 healthy subjects, underwent two-dimensional speckle-tracking echocardiography and late gadolinium-enhanced cardiac magnetic resonance. Scar extent was determined as the relative amount of hyperenhancement using late gadolinium-enhanced cardiac magnetic resonance in an 18-segment model (0% hyperenhancement = normal; 1%-50% = subendocardial scar; 51%-100% = transmural scar). In the same 18-segment model, peak systolic circumferential strain and longitudinal strain were calculated separately for the endocardial and epicardial layers as well as the full-wall myocardial thickness. All strain parameters showed cutoff values (area under the curve > 0.69) that allowed the discrimination of normal versus scar segments but not of transmural versus subendocardial scars. This was true for all strain parameters analyzed, without differences in efficacy between longitudinal and circumferential strain and subendocardial, subepicardial, and full-wall-thickness strain values. Circumferential and longitudinal strain in normal segments showed transmural and basoapical gradients (greatest values at the subendocardial layer and apex). In segments with scar, transmural gradient was maintained, whereas basoapical gradient was lost because the reduction of strain values in the presence of the scar was greater at the apex. The two-dimensional speckle-tracking echocardiographic values distinguish scar presence but not transmurality; thus, they are not useful predictors of scar segment viability. It remains unclear why there is a greater strain value reduction in the presence of a scar at the apical
Oda, Seitaro; Utsunomiya, Daisuke; Nakaura, Takeshi; Yuki, Hideaki; Kidoh, Masafumi; Morita, Kosuke; Takashio, Seiji; Yamamuro, Megumi; Izumiya, Yasuhiro; Hirakawa, Kyoko; Ishida, Toshifumi; Tsujita, Kenichi; Ueda, Mitsuharu; Yamashita, Taro; Ando, Yukio; Hata, Hiroyuki; Yamashita, Yasuyuki
2017-06-23
We explored the usefulness of myocardial strain analysis on cardiac magnetic resonance imaging (CMR) scans for the identification of cardiac amyloidosis.Methods and Results:The 61 patients with systemic amyloidosis underwent 3.0-T CMR, including CMR tagging and late-gadolinium enhanced (LGE) imaging. The circumferential strain (CS) of LGE-positive and LGE-negative patients was measured on midventricular short-axis images and compared. Logistic regression modeling of CMR parameters was performed to detect patients with LGE-positive cardiac amyloidosis. Of the 61 patients with systemic amyloidosis 48 were LGE-positive and 13 were LGE-negative. The peak CS was significantly lower in the LGE-positive than in the LGE-negative patients (-9.5±2.3 vs. -13.3±1.4%, P<0.01). The variability in the peak CS time was significantly greater in the LGE-positive than in the LGE-negative patients (46.1±24.5 vs. 21.2±20.1 ms, P<0.01). The peak CS significantly correlated with clinical biomarkers. The sensitivity, specificity, and accuracy of the diagnostic model using CS parameters for the identification of LGE-positive amyloidosis were 93.8%, 76.9%, and 90.2%, respectively. Myocardial strain analysis by CMR helped detect LGE-positive amyloidosis without the need for contrast medium. The peak CS and variability in the peak CS time may correlate with the severity of cardiac amyloid deposition and may be more sensitive than LGE imaging for the detection of early cardiac disease in patients with amyloidosis.
Influenza virus surveillance, vaccine strain selection, and manufacture.
Stöhr, Klaus; Bucher, Doris; Colgate, Tony; Wood, John
2012-01-01
As outlined in other chapters, the influenza virus, existing laboratory diagnostic abilities, and disease epidemiology have several peculiarities that impact on the timing and processes for the annual production of influenza vaccines. The chapter provides an overview on the key biological and other factors that influence vaccine production. They are the reason for an "annual circle race" beginning with global influenza surveillance during the influenza season in a given year to the eventual supply of vaccines 12 months later in time before the next seasonal outbreak and so on. As influenza vaccines are needed for the Northern and Southern Hemisphere outbreaks in fall and spring, respectively, global surveillance and vaccine production has become a year round business. Its highlights are the WHO recommendations on vaccine strains in February and September and the eventual delivery of vaccine doses in time before the coming influenza season. In between continues vaccine strain and epidemiological surveillance, preparation of new high growth reassortments, vaccine seed strain preparation and development of standardizing reagents, vaccine bulk production, fill-finishing and vaccine release, and in some regions, clinical trials for regulatory approval.
Effect of strain rate and dislocation density on the twinning behavior in tantalum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Florando, Jeffrey N., E-mail: florando1@llnl.gov; Swift, Damian C.; Barton, Nathan R.
2016-04-15
The conditions which affect twinning in tantalum have been investigated across a range of strain rates and initial dislocation densities. Tantalum samples were subjected to a range of strain rates, from 10{sup −4}/s to 10{sup 3}/s under uniaxial stress conditions, and under laser-induced shock-loading conditions. In this study, twinning was observed at 77 K at strain rates from 1/s to 10{sup 3}/s, and during laser-induced shock experiments. The effect of the initial dislocation density, which was imparted by deforming the material to different amounts of pre-strain, was also studied, and it was shown that twinning is suppressed after a givenmore » amount of pre-strain, even as the global stress continues to increase. These results indicate that the conditions for twinning cannot be represented solely by a critical global stress value, but are also dependent on the evolution of the dislocation density. In addition, the analysis shows that if twinning is initiated, the nucleated twins may continue to grow as a function of strain, even as the dislocation density continues to increase.« less
Hoshino, Yasutaka; Honma, Shinjiro; Jones, Ronald W; Ross, Jerri; Santos, Norma; Gentsch, Jon R; Kapikian, Albert Z; Hesse, Richard A
2005-02-05
Of five globally important VP7 (G) serotypes (G1-4 and 9) of group A rotaviruses (the single most important etiologic agents of infantile diarrhea worldwide), G9 continues to attract considerable attention because of its unique natural history. Serotype G9 rotavirus was isolated from a child with diarrhea first in the United States in 1983 and subsequently in Japan in 1985. Curiously, soon after their detection, G9 rotaviruses were not detected for about a decade in both countries and then reemerged in both countries in the mid-1990s. Unexpectedly, however, such reemerged G9 strains were distinct genetically and molecularly from those isolated in the 1980s. Thus, the origin of the reemerged G9 viruses remains an enigma. Sequence analysis has demonstrated that the G9 rotavirus VP7 gene belongs to one of at least three phylogenetic lineages: lineage 1 (strains isolated in the 1980s in the United States and Japan), lineage 2 (strains first isolated in 1986 and exclusively in India thus far), and lineage 3 (strains that emerged/reemerged in the mid-1990s). Currently, lineage 3 G9 viruses are the most frequently detected G9 strains globally. We characterized a porcine rotavirus (A2 strain) isolated in the United States that was known to belong to the P[7] genotype but had not been serotyped by neutralization. The A2 strain was found to bear serotype G9 and P9 specificities as well as NSP4 [B] and subgroup I characteristics. By VP7-specific neutralization, the porcine G9 strain was more closely related to lineage 3 viruses than to lineage 1 or 2 viruses. Furthermore, by sequence analysis, the A2 VP7 was shown to belong to lineage 3 G9. These findings raise intriguing questions regarding possible explanations for the emergence of variations among the G9 strains.
Pospiech, Peter; Nagel, Florian; Gebhart, Florian; Nothdurft, Frank P; Mitov, Gergo
2012-12-01
The objective of this in vitro study was to investigate the behavior of different composite restorative materials under the load of cast circumferential clasps for removable dental prostheses (RDPs). In 60 human molars, standardized mesial-occlusal-distal cavities were prepared. The cavities were restored with the following materials: Definite, Tetric Ceram, SureFil, Heliomolar RO, Ariston pHc, and Oralloy, and provided with a rest seat. The rest seats were subjected to 5,000 cycles of thermal cycling and 1,200,000 masticatory cycles in a mastication simulator via cobalt-chromium circumferential clasps cast to standardized frameworks in a laboratory model designed to simulate the biomechanics of a free-end denture base. Fracture analysis of the restorations was performed by light microscopy. Before and after loading, material wear was measured with a 3D-laser scanner, and an analysis of the marginal quality was performed in an SEM at ×200 applying the replica technique. No significant differences in the fracture behavior among the composite materials were found; the amalgam control group showed a significantly higher fracture resistance. Regarding the wear of the materials, the composites Definite and SureFil exhibited a behavior similar to that of amalgam. The other composites demonstrated higher wear rates. The initial marginal quality was significantly worse for Ariston pHc. The marginal adaptation decreased significantly after thermal and mechanical loading for Definite and Ariston pHc. In terms of the investigated aspects of mechanical performance, the tested composites seemed to be inferior to amalgam. Further clinical studies are needed to evaluate the ability of composite restorations to provide support for RDP clasps. The use of composites as direct restoration materials should be avoided in teeth, which serve as abutments for clasp-retained RDPs.
Ge, Shaoqing; Wu, Bei; Bailey, Donald E; Dong, XinQi
2017-07-01
Limited research is available on the relationship between social support, social strain, and cognitive function among community-dwelling U.S. Chinese older adults. This study aims to examine the associations between social support/strain and cognitive outcomes. Data were drawn from the Population-Based Study of Chinese Elderly (N = 3,159). Cognitive function was measured by a battery of tests including the East Boston Memory Test, the Digit Span Backwards assessment, and the Symbol Digit Modalities Test. Social support and strain were measured by the scales drawn from the Health and Retirement study. Multiple regression analyses were conducted. Social support was significantly associated with global cognitive function (β = .11, SE = .02, p < .001), episodic memory (β = .11, SE = .03, p < .001), working memory (β = .18, SE = .08, p < .05), and executive function (β = 1.44, SE = .37, p < .001). Social strain was significantly associated with global cognitive function (β = .23, SE = .05, p < .001), episodic memory (β = .27, SE = .07, p < .001), working memory (β = .34, SE = .17, p < .05), and executive function (β = 2.75, SE = .85, p < .01). In terms of sources of social support/strain, higher support from friends was significantly associated with higher global cognitive function (β = .04, SE = .02, p < .05), higher episodic memory (β = .05, SE = .02, p < .05), and higher executive function (β = .71, SE = .29, p < .05). Higher strain from spouse was significantly associated with higher global cognitive function (β = .10, SE = .03, p < .01), higher episodic memory (β = .11, SE = .04, p < .01), and higher executive function (β = 1.28, SE = .49, p < .01). Higher strain from friends was significantly associated with higher executive function (β = 3.59, SE = 1.17, p < .01). Social support and strain were associated with cognitive outcomes. Future longitudinal studies should be conducted. © The Author 2017. Published by Oxford University Press on behalf of
Parsaee, Mozhgan; Saedi, Sedigheh; Joghataei, Pegah; Azarkeivan, Azita; Alizadeh Sani, Zahra
2017-10-01
β-Thalassemia is an inherited hemoglobin disorder resulting in chronic hemolytic anemia requiring chronic transfusion therapy. Cardiac involvement is the main cause of death in patients with thalassemia major. The narrow border is between overt myocardial dysfunction and clinically silent left ventricular (LV) dysfunction in patients with thalassemia. Therefore, we need novel parameters in different imaging techniques to discover cardiac involvement in an early and subtle stage. We explore to find a novel, straightforward and informative parameter in echocardiography as a noninvasive, economical and really routine in clinical practice. In this prospective study, 55 patients, who are known cases of β-thalassemia major, receiving long-term blood transfusions and undergoing iron chelation therapy were enrolled. Ferritin level, cardiac magnetic resonance (CMR) T2 * value, full conventional echocardiography and speckle tracking, LV regional circumferential and longitudinal strain values (%) and time-to-peak strain (ms) of 17 segments cardiac model in eyeball tomogram were measured. There was a significant reduction in global longitudinal strain (GLS) (-20.9% ± 1.9 vs. -22.2 ± 1.03) and also basal segments longitudinal strain compared to normal subjects group (-17.4% ± 2.7 vs. -19.6% ± 1.2). There was no significant difference in circumferential strain value between thalassemia patients and normal control group. Interestingly, there was no significant correlation between GLS and CMR T2 * values showing no association between cardiac iron load and longitudinal strain. Speckle tracking echocardiography could be used as a feasible method for evaluating subclinical myocardial dysfunction in patients with thalassemia major. Echocardiography, using GLS, could predict clinically silent myocardial dysfunction independent of CMR (T2 * value) and extension of iron deposition. Our study also puts forward other causes such as chronic tissue hypoxia resulting
Suzuki, Ryohei; Mochizuki, Yohei; Yoshimatsu, Hiroki; Teshima, Takahiro; Matsumoto, Hirotaka; Koyama, Hidekazu
2017-12-01
Objectives Hypertrophic cardiomyopathy, a primary disorder of the myocardium, is the most common cardiac disease in cats. However, determination of myocardial deformation with two-dimensional speckle-tracking echocardiography in cats with various stages of hypertrophic cardiomyopathy has not yet been reported. This study was designed to measure quantitatively multidirectional myocardial deformations of cats with hypertrophic cardiomyopathy. Methods Thirty-two client-owned cats with hypertrophic cardiomyopathy and 14 healthy cats serving as controls were enrolled and underwent assessment of myocardial deformation (peak systolic strain and strain rate) in the longitudinal, radial and circumferential directions. Results Longitudinal and radial deformations were reduced in cats with hypertrophic cardiomyopathy, despite normal systolic function determined by conventional echocardiography. Cats with severely symptomatic hypertrophic cardiomyopathy also had lower peak systolic circumferential strain, in addition to longitudinal and radial strain. Conclusions and relevance Longitudinal and radial deformation may be helpful in the diagnosis of hypertrophic cardiomyopathy. Additionally, the lower circumferential deformation in cats with severe hypertrophic cardiomyopathy may contribute to clinical findings of decompensation, and seems to be related to severe cardiac clinical signs. Indices of multidirectional myocardial deformations by two-dimensional speckle-tracking echocardiography may be useful markers and help to distinguish between cats with hypertrophic cardiomyopathy and healthy cats. Additionally, they may provide more detailed assessment of contractile function in cats with hypertrophic cardiomyopathy.
Kermavnar, Tjaša; Power, Valerie; de Eyto, Adam; O'Sullivan, Leonard W
2018-02-01
In this article, we review the literature on quantitative sensory testing of deep somatic pain by means of computerized cuff pressure algometry (CPA) in search of pressure-related safety guidelines for wearable soft exoskeleton and robotics design. Most pressure-related safety thresholds to date are based on interface pressures and skin perfusion, although clinical research suggests the deep somatic tissues to be the most sensitive to excessive loading. With CPA, pain is induced in deeper layers of soft tissue at the limbs. The results indicate that circumferential compression leads to discomfort at ∼16-34 kPa, becomes painful at ∼20-27 kPa, and can become unbearable even below 40 kPa.
Baker, John E; Fish, Brian L; Su, Jidong; Haworth, Steven T; Strande, Jennifer L; Komorowski, Richard A; Migrino, Raymond Q; Doppalapudi, Anil; Harmann, Leanne; Li, X Allen; Hopewell, John W; Moulder, John E
2009-01-01
Purpose To determine the impact of 10 Gy total body irradiation (TBI) or local thorax irradiation, a dose relevant to a radiological terrorist threat, on lipid and liver profile, coronary microvasculature and ventricular function. Materials and methods WAG/RijCmcr rats received 10 Gy TBI followed by bone marrow transplantation, or 10 Gy local thorax irradiation. Age-matched, non-irradiated rats served as controls. The lipid profile and liver enzymes, coronary vessel morphology, nitric oxide synthase (NOS) isoforms, protease activated receptor (PAR)-1 expression and fibrinogen levels were compared. Two dimensional strain echocardiography assessed global radial and circumferential strain on the heart. Results TBI resulted in a sustained increase in total and low density lipoprotein (LDL) cholesterol (190±8 vs. 58±6; 82±8 vs. 13±3 mg/dL, respectively). The density of small coronary arterioles was decreased by 32%. Histology revealed complete blockage of some vessels while cardiomyocytes remained normal. TBI resulted in cellular peri-arterial fibrosis whereas control hearts had symmetrical penetrating vessels with less collagen and fibroblasts. TBI resulted in a 32±4% and 28±3% decrease in endothelial NOS and inducible NOS protein respectively, and a 21±4% and 35±5% increase in fibrinogen and PAR-1 protein respectively, after 120 days. TBI reduced radial strain (19±8 vs. 46±7%) and circumferential strain (-8±3 vs. −15±3%) compared to controls. Thorax-only irradiation produced no changes over the same time frame. Conclusions TBI with 10 Gy, a dose relevant to radiological terrorist threats, worsened lipid profile, injured coronary microvasculature, altered endothelial physiology and myocardial mechanics. These changes were not manifest with local thorax irradiation. Non-thoracic circulating factors may be promoting radiation-induced injury to the heart. PMID:19995235
Smelov, Vitaly; Vrbanac, Alison; van Ess, Eleanne F.; Noz, Marlies P.; Wan, Raymond; Eklund, Carina; Morgan, Tyler; Shrier, Lydia A.; Sanders, Blake; Dillner, Joakim; de Vries, Henry J. C.; Morre, Servaas A.; Dean, Deborah
2017-01-01
Chlamydia trachomatis (Ct) is the leading cause of bacterial sexually transmitted diseases worldwide. The Ct Multi Locus Sequence Typing (MLST) scheme is effective in differentiating strain types (ST), deciphering transmission patterns and treatment failure, and identifying recombinant strains. Here, we analyzed 323 reference and clinical samples, including 58 samples from Russia, an area that has not previously been represented in Ct typing schemes, to expand our knowledge of the global diversification of Ct STs. The 323 samples resolved into 84 unique STs, a 3.23 higher typing resolution compared to the gold standard single locus ompA genotyping. Our MLST scheme showed a high discriminatory index, D, of 0.98 (95% CI 0.97–0.99) confirming the validity of this method for typing. Phylogenetic analyses revealed distinct branches for the phenotypic diseases of lymphogranuloma venereum, urethritis and cervicitis, and a sub-branch for ocular trachoma. Consistent with these findings, single nucleotide polymorphisms were identified that significantly correlated with each phenotype. While the overall number of unique STs per region was comparable across geographies, the number of STs was greater for Russia with a significantly higher ST/sample ratio of 0.45 (95% CI: 0.35–0.53) compared to Europe or the Americas (p < 0.009), which may reflect a higher level of sexual mixing with the introduction of STs from other regions and/or reassortment of alleles. Four STs were found to be significantly associated with a particular geographic region. ST23 [p = 0.032 (95% CI: 1–23)], ST34 [p = 0.019 (95% CI: 1.1–25)]; and ST19 [p = 0.001 (95% CI: 1.7–34.7)] were significantly associated with Netherlands compared to Russia or the Americas, while ST 30 [p = 0.031 (95% CI: 1.1–17.8)] was significantly associated with the Americas. ST19 was significantly associated with Netherlands and Russia compared with the Americans [p = 0.001 (95% CI: 1.7–34.7) and p = 0.006 (95% CI: 1.5
Beaton, Andrea; Richards, Hedda; Ploutz, Michelle; Gaur, Lasya; Aliku, Twalib; Lwabi, Peter; Ensing, Greg; Sable, Craig
2017-08-01
Identification of patients with latent rheumatic heart disease by echocardiography presents a unique opportunity to prevent disease progression. Myocardial strain is a more sensitive indicator of cardiac performance than traditional measures of systolic function. The objective of this study was to test the hypothesis that abnormalities in myocardial strain may be present in children with latent rheumatic heart disease. Standard echocardiography images with electrocardiogram gating were obtained from Ugandan children found to have latent rheumatic heart disease as well as control subjects. Traditional echocardiography measures of systolic function were obtained, and offline global longitudinal strain analysis was performed. Comparison between groups was performed using strain as a continuous (Mann-Whitney U-test) and categorical (cut-off 5th percentile for age) variable. Our study included 14 subjects with definite rheumatic heart disease, 13 with borderline rheumatic heart disease, and 112 control subjects. None of the subjects had abnormal left ventricular size or ejection fraction. Global longitudinal strain was lower than the 5th percentile in 44% of the subjects with any rheumatic heart disease (p=0.002 versus controls) and 57% of the subjects with definite rheumatic heart disease (p=0.03). The mean absolute strain values were significantly lower when comparing subjects with any rheumatic heart disease with controls (20.4±3.95 versus 22.4±4.35, p=0.025) and subjects with definite rheumatic heart disease with controls (19.9±4.25 versus 22.4±4.35, p=0.033). Global longitudinal strain is decreased in subjects with rheumatic heart disease in the absence of abnormal systolic function. Larger studies with longer-term follow-up are required to determine whether there is a role for strain to help better understand the pathophysiology of latent rheumatic heart disease.
Elsyad, Moustafa Abdou; Khirallah, Ahmed Samir
2016-11-01
Circumferential marginal bone around 2 splinted and nonsplinted immediately loaded implants in the edentulous mandible has not been previously investigated. The purpose of this randomized controlled clinical trial was to assess circumferential bone loss around splinted and nonsplinted immediately loaded implants retaining mandibular overdentures, using cone beam computed tomography (CBCT). Thirty participants with complete edentulism were allocated to 2 groups and received 2 implants in the canine region of the mandible. Implants were either left nonsplinted (with ball attachment [BA]) or splinted (with bar attachment [RA]). Mandibular overdentures were connected to the implants 1 week later. CBCT was used to evaluate vertical bone loss (VBL) and horizontal bone loss (HBLo) bone loss at the distal (D), buccal (B), mesial (M), and lingual (L) sites of each implant upon overdenture insertion (baseline, T0), 1 year (T1) and 3 years (T3) after insertion. Repeated measures ANOVA was used for statistical analysis (α=.05). No significant difference in the survival rate (93.3% for BA and 100% for RA) was found between groups (P=.156). VBL and HBLo increased significantly at T3 compared with T1 for both groups (P<.005). After 3 years, VBL were 1.36 ±0.57 mm and 1.0 ±0.44 mm and HBLo were 0.88 ±0.48 mm for BA and 0.77 ±0.53 mm for RA. At T1 and T3, BA had more significant VBL than RA (P<.001), while HBLo did not differ significantly between groups. For both groups, a significant difference was found in VBL and HBLo between implant sites (P<.001). The B site recorded the highest VBL, and the L site recorded the lowest VBL. The M and D sites recorded the highest HBLo, and the B and L sites recorded the lowest HBLo. Two nonsplinted immediately loaded implants retaining mandibular overdentures were associated with significantly higher vertical and horizontal circumferential bone loss than those associated with splinted implants after a follow-up of 3 years. Copyright
Fabiani, Iacopo; Scatena, Cristian; Mazzanti, Chiara Maria; Conte, Lorenzo; Pugliese, Nicola Riccardo; Franceschi, Sara; Lessi, Francesca; Menicagli, Michele; De Martino, Andrea; Pratali, Stefano; Bortolotti, Uberto; Naccarato, Antonio Giuseppe; La Carrubba, Salvatore; Di Bello, Vitantonio
2016-08-27
Myocardial fibrosis (MF) is a deleterious consequence of aortic valve stenosis (AVS). Global longitudinal strain (GLS) is a novel left ventricular (LV) functional parameter potentially useful to non-invasively estimate MF. MicroRNAs (miRNAs) are non-coding small ribonucleic acids (RNA) modulating genes function, mainly through RNA degradation. miRNA-21 is a biomarker associated with MF in pressure overload. The aim of the present study was to find an integrated algorithm for detection of MF using a combined approach with both bio- and functional markers. Thirty-six patients (75.2 ± 8 y.o.; 63 % Female) with severe AVS and preserved LV ejection fraction (EF), candidate to surgical aortic valve replacement (sAVR) were enrolled. Clinical, bio-humoral evaluation (including plasmatic miRNA-21 collected using specific tubes, PAXgene, for stabilization of peripheral RNA) and a complete echocardiographic study, including GLS and septal strain, were performed before sAVR. Twenty-eight of those patients underwent sAVR and, in 23 of them, an inter-ventricular septum biopsy was performed. Tissues were fixed in formalin and embedded in paraffin. Sections were stained with Hematoxylin and Eosin for histological evaluation and with histochemical Masson trichrome for collagen fibers. The different components were calculated and expressed as micrometers(2). To evaluate tissue miRNA components, sections 2-μm thick were cut using a microtome blade for each slide. Regression analysis was performed to test association between dependent variable and various predictors included in the model. Despite a preserved EF (66 ± 11 %), patients presented altered myocardial deformation parameters (GLS -14,02 ± 3.8 %; septal longitudinal strain, SSL -9.63 ± 2.9 %; septal longitudinal strain rate, SL-Sr -0.58 ± 0.17 1/s; Septal Longitudinal early-diastolic strain rate, SL-SrE 0.62 ± 0.32 1/s). The extent of MF showed an inverse association with both GLS and septal
NASA Technical Reports Server (NTRS)
Gallagher, James J.
1948-01-01
This report presents the results of the tests of a power-plant installation to improve the circumferential pressure-recovery distribution at the face of the engine. An underslung "C" cowling was tested with two propellers with full cuffs and with a modification to one set of cuffs. Little improvement was obtained because the base sections of the cuffs were stalled. A set of guide vanes boosted the over-all pressures and helped the pressure recoveries for a few of the cylinders. Making the underslung cowling into a symmetrical "C" cowling evened the pressure distribution; however, no increases in front pressures were obtained. The pressures at the top cylinders remained low and the high pressures at the bottom cylinders were reduced. At higher powers and engine speeds, the symmetrical cowling appeared best from the standpoint of over-all cooling characteristics.
Vascular Repair by Circumferential Cell Therapy Using Magnetic Nanoparticles and Tailored Magnets.
Vosen, Sarah; Rieck, Sarah; Heidsieck, Alexandra; Mykhaylyk, Olga; Zimmermann, Katrin; Bloch, Wilhelm; Eberbeck, Dietmar; Plank, Christian; Gleich, Bernhard; Pfeifer, Alexander; Fleischmann, Bernd K; Wenzel, Daniela
2016-01-26
Cardiovascular disease is often caused by endothelial cell (EC) dysfunction and atherosclerotic plaque formation at predilection sites. Also surgical procedures of plaque removal cause irreversible damage to the EC layer, inducing impairment of vascular function and restenosis. In the current study we have examined a potentially curative approach by radially symmetric re-endothelialization of vessels after their mechanical denudation. For this purpose a combination of nanotechnology with gene and cell therapy was applied to site-specifically re-endothelialize and restore vascular function. We have used complexes of lentiviral vectors and magnetic nanoparticles (MNPs) to overexpress the vasoprotective gene endothelial nitric oxide synthase (eNOS) in ECs. The MNP-loaded and eNOS-overexpressing cells were magnetic, and by magnetic fields they could be positioned at the vascular wall in a radially symmetric fashion even under flow conditions. We demonstrate that the treated vessels displayed enhanced eNOS expression and activity. Moreover, isometric force measurements revealed that EC replacement with eNOS-overexpressing cells restored endothelial function after vascular injury in eNOS(-/-) mice ex and in vivo. Thus, the combination of MNP-based gene and cell therapy with custom-made magnetic fields enables circumferential re-endothelialization of vessels and improvement of vascular function.
From local to global measurements of nonclassical nonlinear elastic effects in geomaterials
Lott, Martin; Remillieux, Marcel C.; Le Bas, Pierre-Yves; ...
2016-09-07
Here, the equivalence between local and global measures of nonclassical nonlinear elasticity is established in a slender resonant bar. Nonlinear effects are first measured globally using nonlinear resonance ultrasound spectroscopy (NRUS), which monitors the relative shift of the resonance frequency as a function of the maximum dynamic strain in the sample. Subsequently, nonlinear effects are measured locally at various positions along the sample using dynamic acousto elasticity testing (DAET). Finally, after correcting analytically the DAET data for three-dimensional strain effects and integrating numerically these corrected data along the length of the sample, the NRUS global measures are retrieved almost exactly.
Bourfiss, Mimount; Vigneault, Davis M; Aliyari Ghasebeh, Mounes; Murray, Brittney; James, Cynthia A; Tichnell, Crystal; Mohamed Hoesein, Firdaus A; Zimmerman, Stefan L; Kamel, Ihab R; Calkins, Hugh; Tandri, Harikrishna; Velthuis, Birgitta K; Bluemke, David A; Te Riele, Anneline S J M
2017-09-01
Regional right ventricular (RV) dysfunction is the hallmark of Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy (ARVD/C), but is currently only qualitatively evaluated in the clinical setting. Feature Tracking Cardiovascular Magnetic Resonance (FT-CMR) is a novel quantitative method that uses cine CMR to calculate strain values. However, most prior FT-CMR studies in ARVD/C have focused on global RV strain using different software methods, complicating implementation of FT-CMR in clinical practice. We aimed to assess the clinical value of global and regional strain using FT-CMR in ARVD/C and to determine differences between commercially available FT-CMR software packages. We analyzed cine CMR images of 110 subjects (39 overt ARVD/C [mutation+/phenotype+], 40 preclinical ARVD/C [mutation+/phenotype-] and 31 control) for global and regional (subtricuspid, anterior, apical) RV strain in the horizontal longitudinal axis using four FT-CMR software methods (Multimodality Tissue Tracking, TomTec, Medis and Circle Cardiovascular Imaging). Intersoftware agreement was assessed using Bland Altman plots. For global strain, all methods showed reduced strain in overt ARVD/C patients compared to control subjects (p < 0.041), whereas none distinguished preclinical from control subjects (p > 0.275). For regional strain, overt ARVD/C patients showed reduced strain compared to control subjects in all segments which reached statistical significance in the subtricuspid region for all software methods (p < 0.037), in the anterior wall for two methods (p < 0.005) and in the apex for one method (p = 0.012). Preclinical subjects showed abnormal subtricuspid strain compared to control subjects using one of the software methods (p = 0.009). Agreement between software methods for absolute strain values was low (Intraclass Correlation Coefficient = 0.373). Despite large intersoftware variability of FT-CMR derived strain values, all four software methods distinguished
Prevalence of job strain among Indian foundry shop floor workers.
Mohan, G Madhan; Elangovan, S; Prasad, P S S; Krishna, P Rama; Mokkapati, Anil Kumar
2008-01-01
Global competition in manufacturing sector demand higher productivity levels. In this context, workers in this sector are set with high output targets, leading to job strain. In addition to the strain, hazardous conditions also prevail in some of the manufacturing processes like foundry activities. This paper attempts to appraise the prevalence of job strain among foundry shop floor workers in India with the help of Demands-Control model [8]. In this study, data was collected through a survey using 49-item Job Content Questionnaire (JCQ) [9], a widely used and well-validated test for job strain. Then the data was subjected to statistical analysis after ascertaining the reliability. This survey has revealed that 25% of workers in foundry were experiencing high job strain. Hazardous working conditions, limited decision making authority, etc. appear to be the main contributing factors for the higher levels of strain.
Borgia, Francesco; Pezzullo, Enrica; Schiano Lomoriello, Vincenzo; Sorrentino, Regina; Lo Iudice, Francesco; Cocozza, Sara; Della Casa, Roberto; Parenti, Giancarlo; Strisciuglio, Pietro; Trimarco, Bruno; Galderisi, Maurizio
2017-02-01
Mucopolysaccharidoses (MPS) are inherited lysosomal storage disorders caused by deficiency of required glycosaminoglycans breakdown enzymes, inducing cardiac involvement. Little is known about myocardial deformation involvement in MPS. Our aim was to assess biventricular structure and function in asymptomatic children with MPS using standard echo Doppler and 2D speckle tracking (STE). Fifteen MPS children (one type I, six type II, three type III A, one III B, three IV A, one VI), asymptomatic for cardiac symptoms, and 15 age and sex-matched healthy controls underwent echo Doppler and STE. Left ventricular (LV) wall thicknesses, diameters, and mass were normalized by z-score. LV global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS) at papillary muscles, LV twisting, and right ventricular (RV) GLS were measured. The two groups were comparable for body mass index, heart rate, and blood pressure. LV mass index and relative wall thickness were higher in MPS. Ejection fraction (EF), and s' velocity did not differ between the two groups. E/A ratio was lower and E/e' higher in MPS. Tricuspid annular plane systolic excursion, RV s' and e' were lower in MPS. LV GLS did not differ between the two groups, but GCS (P=.014), GRS (P=.023), twisting (P=.012), and RV GLS (P<.001) were lower in the MPS group. LV strain abnormalities are detectable in MPS pediatric patients, independently of MPS type, when EF is still normal. RV GLS is also involved consensually with TAPSE reduction. STE can be useful for detection of subclinical myocardial damage in MPS. © 2017, Wiley Periodicals, Inc.
Sera, Fusako; Jin, Zhezhen; Russo, Cesare; Lee, Edward S; Schwartz, Joseph E; Rundek, Tatjana; Elkind, Mitchell S V; Homma, Shunichi; Sacco, Ralph L; Di Tullio, Marco R
2016-11-01
Left ventricular (LV) global longitudinal strain (GLS) is an early indicator of subclinical cardiac dysfunction, even when LV ejection fraction (LVEF) is normal, and is an independent predictor of cardiovascular events. Ambulatory blood pressure (BP) is a better predictor of cardiovascular events, including heart failure, than office BP. We investigated the association of office and ambulatory BP measurements with subclinical LV systolic dysfunction in a community-based cohort with normal LVEF. Two-dimensional speckle-tracking echocardiography and 24-hour ambulatory BP monitoring were performed in 577 participants (mean age 70±9 years; 60% women) with LVEF ≥50% from the Cardiovascular Abnormalities and Brain Lesions (CABL) study. Univariable and multivariable linear regression analyses were used to assess the associations of BP measures with GLS. Higher ambulatory and office BP values were consistently associated with impaired GLS. After adjustment for pertinent covariates (age, sex, race/ethnicity, body mass index, diabetes mellitus, coronary artery disease, LV mass index, and antihypertensive medication), office diastolic BP and ambulatory systolic and diastolic BPs (24-hour, daytime and nighttime) were independently associated with GLS (P = 0.003 for office DBP, P ≤ 0.001 for all ambulatory BPs). When ambulatory and office BP values were included in the same model, all ambulatory BP measures remained significantly associated with GLS (all P < 0.01), whereas office BP values were not. Ambulatory BP values are significantly associated with impaired GLS and the association is stronger than for office BP. Ambulatory BP monitoring might have a role in the risk stratification of hypertensive patients for early LV dysfunction.
Vallabhajosyula, Saraschandra; Rayes, Hamza A; Sakhuja, Ankit; Murad, Mohammad Hassan; Geske, Jeffrey B; Jentzer, Jacob C
2018-01-01
The data on speckle-tracking echocardiography (STE) in patients with sepsis are limited. This systematic review from 1975 to 2016 included studies in adults and children evaluating cardiovascular dysfunction in sepsis, severe sepsis, and septic shock utilizing STE for systolic global longitudinal strain (GLS). The primary outcome was short- or long-term mortality. Given the significant methodological and statistical differences between published studies, combining the data using meta-analysis methods was not appropriate. A total of 120 studies were identified, with 5 studies (561 patients) included in the final analysis. All studies were prospective observational studies using the 2001 criteria for defining sepsis. Three studies demonstrated worse systolic GLS to be associated with higher mortality, whereas 2 did not show a statistically significant association. Various cutoffs between -10% and -17% were used to define abnormal GLS across studies. This systematic review revealed that STE may predict mortality in patients with sepsis; however, the strength of evidence is low due to heterogeneity in study populations, GLS technologies, cutoffs, and timing of STE. Further dedicated studies are needed to understand the optimal application of STE in patients with sepsis.
Nagai, Tomoo; Hamabe, Akira; Arakawa, Junko; Tabata, Hirotsugu; Nishioka, Toshihiko
2017-11-01
The purpose of this study was to evaluate left ventricular (LV) deformation and LV dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome and to identify the factors that affect the efficacy of radiofrequency catheter ablation (RFCA). Thirty patients (26 men, mean age 40 ± 12 years) with WPW syndrome were prospectively recruited for this study. They underwent 2-dimensional transthoracic echocardiography with speckle tracking analysis before RFCA and again within 48 hours after RFCA. Control group consisted of 15 age and sex-matched healthy volunteers. The patients had significantly lower LV ejection fraction (LVEF), global longitudinal strain (S l ), and global circumferential strain (S c ) compared with healthy controls (64% ± 8% vs 68% ± 5%, P = .049; -17.6% ± 3.2% vs -19.9% ± 3.3%, P = .037, -15.2% ± 2.5% vs -19.4% ± 2.5%, P < .0001, respectively). Patients had a significantly higher dyssynchrony index relative to healthy controls (58.4 ± 49.0 ms vs 36.4 ± 31.1 ms, P = .031). After RFCA, there was a significant increase in LVEF and global S c (68% ± 8% vs 64% ± 8%, P = .005; -17.3% ± 2.0% vs -15.2% ± 2.5%, P < .0001, respectively), along with a significant decrease in the dyssynchrony index (36.9 ± 36.3 ms vs 58.4 ± ms, P < .001) relative to the baseline values. Logistic regression revealed that the baseline dyssynchrony index was a predictor of LVEF improvement after RFCA (odds ratio: 1.060, P = .038). In WPW syndrome, impaired LV circumferential deformation can be restored by RFCA with concomitant improvement in LV dyssynchrony and LVEF. © 2017, Wiley Periodicals, Inc.
Temperature affects the morphology and calcification of Emiliania huxleyi strains
NASA Astrophysics Data System (ADS)
Rosas-Navarro, Anaid; Langer, Gerald; Ziveri, Patrizia
2016-05-01
The global warming debate has sparked an unprecedented interest in temperature effects on coccolithophores. The calcification response to temperature changes reported in the literature, however, is ambiguous. The two main sources of this ambiguity are putatively differences in experimental setup and strain specificity. In this study we therefore compare three strains isolated in the North Pacific under identical experimental conditions. Three strains of Emiliania huxleyi type A were grown under non-limiting nutrient and light conditions, at 10, 15, 20 and 25 °C. All three strains displayed similar growth rate versus temperature relationships, with an optimum at 20-25 °C. Elemental production (particulate inorganic carbon (PIC), particulate organic carbon (POC), total particulate nitrogen (TPN)), coccolith mass, coccolith size, and width of the tube element cycle were positively correlated with temperature over the sub-optimum to optimum temperature range. The correlation between PIC production and coccolith mass/size supports the notion that coccolith mass can be used as a proxy for PIC production in sediment samples. Increasing PIC production was significantly positively correlated with the percentage of incomplete coccoliths in one strain only. Generally, coccoliths were heavier when PIC production was higher. This shows that incompleteness of coccoliths is not due to time shortage at high PIC production. Sub-optimal growth temperatures lead to an increase in the percentage of malformed coccoliths in a strain-specific fashion. Since in total only six strains have been tested thus far, it is presently difficult to say whether sub-optimal temperature is an important factor causing malformations in the field. The most important parameter in biogeochemical terms, the PIC : POC ratio, shows a minimum at optimum growth temperature in all investigated strains. This clarifies the ambiguous picture featuring in the literature, i.e. discrepancies between PIC : POC
Zhu, Ling; Shahid, Muhammad A; Markham, John; Browning, Glenn F; Noormohammadi, Amir H; Marenda, Marc S
2018-02-02
The bacterial pathogen Mycoplasma synoviae can cause subclinical respiratory disease, synovitis, airsacculitis and reproductive tract disease in poultry and is a major cause of economic loss worldwide. The M. synoviae strain MS-H was developed by chemical mutagenesis of an Australian isolate and has been used as a live attenuated vaccine in many countries over the past two decades. As a result it may now be the most prevalent strain of M. synoviae globally. Differentiation of the MS-H vaccine from local field strains is important for epidemiological investigations and is often required for registration of the vaccine. The complete genomic sequence of the MS-H strain was determined using a combination of Illumina and Nanopore methods and compared to WVU-1853, the M. synoviae type strain isolated in the USA 30 years before the parent strain of MS-H, and MS53, a more recent isolate from Brazil. The vaccine strain genome had a slightly larger number of pseudogenes than the two other strains and contained a unique 55 kb chromosomal inversion partially affecting a putative genomic island. Variations in gene content were also noted, including a deoxyribose-phosphate aldolase (deoC) fragment and an ATP-dependent DNA helicase gene found only in MS-H. Some of these sequences may have been acquired horizontally from other avian mycoplasma species. MS-H was somewhat more similar to WVU-1853 than to MS53. The genome sequence of MS-H will enable identification of vaccine-specific genetic markers for use as diagnostic and epidemiological tools to better control M. synoviae.
Analysis of 3D strain in the human medial meniscus.
Kolaczek, S; Hewison, C; Caterine, S; Ragbar, M X; Getgood, A; Gordon, K D
2016-10-01
This study presents a method to evaluate three-dimensional strain in meniscal tissue using medical imaging. Strain is calculated by tracking small teflon markers implanted within the meniscal tissue using computed tomography imaging. The results are presented for strains in the middle and posterior third of the medial menisci of 10 human cadaveric knees, under simulated physiologically relevant loading. In the middle position, an average compressive strain of 3.4% was found in the medial-lateral direction, and average tensile strains of 1.4% and 3.5% were found in the anterior-posterior and superior-inferior directions respectively at 5° of knee flexion with an applied load of 1× body weight. In the posterior position, under the same conditions, average compressive strains of 2.2% and 6.3% were found in the medial-lateral and superior-inferior directions respectively, and an average tensile strain of 3.8% was found in the anterior-posterior direction. No statistically significant difference between strain in the middle or posterior of the meniscus or between the global strains is uncovered. Copyright © 2016 Elsevier Ltd. All rights reserved.
Haggerty, Christopher M; Suever, Jonathan D; Pulenthiran, Arichanah; Mejia-Spiegeler, Abba; Wehner, Gregory J; Jing, Linyuan; Charnigo, Richard J; Fornwalt, Brandon K; Fogel, Mark A
2017-12-11
Patients with repaired tetralogy of Fallot (TOF) have progressive, adverse biventricular remodeling, leading to abnormal contractile mechanics. Defining the mechanisms underlying this dysfunction, such as diffuse myocardial fibrosis, may provide insights into poor long-term outcomes. We hypothesized that left ventricular (LV) diffuse fibrosis is related to impaired LV mechanics. Patients with TOF were evaluated with cardiac magnetic resonance in which modified Look-Locker (MOLLI) T1-mapping and spiral cine Displacement encoding (DENSE) sequences were acquired at three LV short-axis positions. Linear mixed modeling was used to define the association between regional LV mechanics from DENSE based on regional T1-derived diffuse fibrosis measures, such as extracellular volume fraction (ECV). Forty patients (26 ± 11 years) were included. LV ECV was generally within normal range (0.24 ± 0.05). For LV mechanics, peak circumferential strains (-15 ± 3%) and dyssynchrony indices (16 ± 8 ms) were moderately impaired, while peak radial strains (29 ± 8%) were generally normal. After adjusting for patient age, sex, and regional LV differences, ECV was associated with log-adjusted LV dyssynchrony index (β = 0.67) and peak LV radial strain (β = -0.36), but not LV circumferential strain. Moreover, post-contrast T1 was associated with log-adjusted LV diastolic circumferential strain rate (β = 0.37). We observed several moderate associations between measures of fibrosis and impaired mechanics, particularly the LV dyssynchrony index and peak radial strain. Diffuse fibrosis may therefore be a causal factor in some ventricular dysfunction in TOF.
Corîci, Oana Maria; Tănasie, Cornelia Andreea; Alexandru, Dragoş Ovidiu; Florescu, Mihaela Corina; Comănescu, Maria Victoria; Kamal, Kamal Constantin; Ţenea-Cojan, Tiberiu Ştefăniţă; Iancău, Maria; Dinescu, Sorin Nicolae
2018-01-01
To assess left ventricular (LV) systolic function and morphology in patients with severe dilated cardiomyopathy (DCM), using both conventional and a complex technique, speckle-tracking echocardiography, and evaluate the correlation between pre-ejection period and left ventricular ejection period (PEP/LVET) ratio, global longitudinal strain (GLS), and severity of the condition. Seventeen patients were enrolled after rigorous criteria. Echocardiography was performed in conventional and speckle-tracking mode, in all patients with DCM, in sinus rhythm. LV dimensions, volumes and ejection fraction (LVEF) were measured. PEP/LVET ratio was obtained from apical 5-chamber axis and was defined as the time between QRS onset and LV ejection reported to LV ejection period. Speckle-tracking imaging was performed in offline mode and GLS was obtained from parasternal 4-, 3-, 2-chamber apical view, by averaging longitudinal peak systolic strain of all 17 LV-segments. New York Heart Association (NYHA) functional class correlated significantly with LVEF (-0.82; p=0.0006), PEP/LVET (0.86; p=0.001) or GLS (0.85; p=0.0002). Considerable correlations were between mitral regurgitation (MR) severity and LVEF (-0.65; p=0.01) or PEP/LVET (0.69; p=0.0059), but higher were between MR severity and GLS (0.76; p=0.0018). Tricuspid regurgitation (TR) grading correlated statistically with LVEF (-0.62; p=0.01), PEP/LVET and GLS (0.6; p=0.018; and 0.62; p=0.014, respectively). As opposed to the parameters in conventional echocardiography, GLS correlated with DCM etiology (p=0.0046) and with the gender (p=0.048). This study demonstrates that, in patients with DCM, assessment of cardiac dyssynchrony can be accurately accomplished by combining parameters in conventional and in speckle-tracking echocardiography.
Adapting global influenza management strategies to address emerging viruses.
Noah, Diana L; Noah, James W
2013-07-15
Death by respiratory complications from influenza infections continues to be a major global health concern. Antiviral drugs are widely available for therapy and prophylaxis, but viral mutations have resulted in resistance that threatens to reduce the long-term utility of approved antivirals. Vaccination is the best method for controlling influenza, but vaccine strategies are blunted by virus antigenic drift and shift. Genetic shift in particular has led to four pandemics in the last century, which have prompted the development of efficient global surveillance and vaccination programs. Although the influenza pandemic of 2009 emphasized the need for the rapid standardization of global surveillance methods and the preparation and dissemination of global assay standards for improved reporting and diagnostic tools, outbreaks of novel influenza strains continue to occur, and current efforts must be enhanced by aggressive public education programs to promote increased vaccination rates in the global population. Recently, a novel H7N9 avian influenza virus with potential to become a pandemic strain emerged in China and was transmitted from animals to humans with a demonstrated >20% mortality rate. Sporadic outbreaks of highly lethal avian virus strains have already increased public awareness and altered annual vaccine production strategies to prevent the natural adaption of this virus to human-to-human transmission. Additional strategies for combating influenza include advancement of new antivirals for unexploited viral or host cellular targets; novel adjuvants and alternate vaccine delivery systems; and development of universal protein, DNA, or multivalent vaccines designed to increase immune responsiveness and enhance public health response times.
NASA Technical Reports Server (NTRS)
Sanger, N. L.
1976-01-01
A transonic fan stage having a design pressure ratio of 1.57 was tested with a 90 degree circumferential distortion imposed on the inlet flow. The rotor diameter was approximately 50.8 cm, and the design pressure ratio was 1.60 at a tip speed of 425 m/sec. Overall performance at 70 and 100 percent of design speed showed a loss of stall pressure ratio and flow range at design speed and no significant loss in stall pressure ratio at 70 percent of design speed. Detailed flow measurements are presented to show the rotor-upstream flow interactions and the attenuation and amplification properties through the stage.
Roos, Viktoria; Ulett, Glen C; Schembri, Mark A; Klemm, Per
2006-01-01
Escherichia coli is the most common organism associated with asymptomatic bacteriuria (ABU). In contrast to uropathogenic E. coli (UPEC), which causes symptomatic urinary tract infections (UTI), very little is known about the mechanisms by which these strains colonize the human urinary tract. The prototype ABU E. coli strain 83972 was originally isolated from a girl who had carried it asymptomatically for 3 years. Deliberate colonization of UTI-susceptible individuals with E. coli 83972 has been used successfully as an alternative approach for the treatment of patients who are refractory to conventional therapy. Colonization with strain 83972 appears to prevent infection with UPEC strains in such patients despite the fact that this strain is unable to express the primary adhesins involved in UTI, viz. P and type 1 fimbriae. Here we investigated the growth characteristics of E. coli 83972 in human urine and show that it can outcompete a representative spectrum of UPEC strains for growth in urine. The unique ability of ABU E. coli 83972 to outcompete UPEC in urine was also demonstrated in a murine model of human UTI, confirming the selective advantage over UPEC in vivo. Comparison of global gene expression profiles of E. coli 83972 grown in lab medium and human urine revealed significant differences in expression levels in the two media; significant down-regulation of genes encoding virulence factors such as hemolysin, lipid A, and capsular polysaccharides was observed in cells grown in urine. Clearly, divergent abilities of ABU E. coli and UPEC to exploit human urine as a niche for persistence and survival suggest that these key differences may be exploited for preventative and/or therapeutic approaches.
Haendiges, Julie; Timme, Ruth; Allard, Marc W; Myers, Robert A; Brown, Eric W; Gonzalez-Escalona, Narjol
2015-01-01
Vibrio parahaemolyticus is the leading cause of foodborne illnesses in the US associated with the consumption of raw shellfish. Previous population studies of V. parahaemolyticus have used Multi-Locus Sequence Typing (MLST) or Pulsed Field Gel Electrophoresis (PFGE). Whole genome sequencing (WGS) provides a much higher level of resolution, but has been used to characterize only a few United States (US) clinical isolates. Here we report the WGS characterization of 34 genomes of V. parahaemolyticus strains that were isolated from clinical cases in the state of Maryland (MD) during 2 years (2012-2013). These 2 years saw an increase of V. parahaemolyticus cases compared to previous years. Among these MD isolates, 28% were negative for tdh and trh, 8% were tdh positive only, 11% were trh positive only, and 53% contained both genes. We compared this set of V. parahaemolyticus genomes to those of a collection of 17 archival strains from the US (10 previously sequenced strains and 7 from NCBI, collected between 1988 and 2004) and 15 international strains, isolated from geographically-diverse environmental and clinical sources (collected between 1980 and 2010). A WGS phylogenetic analysis of these strains revealed the regional outbreak strains from MD are highly diverse and yet genetically distinct from the international strains. Some MD strains caused outbreaks 2 years in a row, indicating a local source of contamination (e.g., ST631). Advances in WGS will enable this type of analysis to become routine, providing an excellent tool for improved surveillance. Databases built with phylogenetic data will help pinpoint sources of contamination in future outbreaks and contribute to faster outbreak control.
Veress, Alexander I.; Klein, Gregory; Gullberg, Grant T.
2013-01-01
Tmore » he objectives of the following research were to evaluate the utility of a deformable image registration technique known as hyperelastic warping for the measurement of local strains in the left ventricle through the analysis of clinical, gated PE image datasets. wo normal human male subjects were sequentially imaged with PE and tagged MRI imaging. Strain predictions were made for systolic contraction using warping analyses of the PE images and HARP based strain analyses of the MRI images. Coefficient of determination R 2 values were computed for the comparison of circumferential and radial strain predictions produced by each methodology. here was good correspondence between the methodologies, with R 2 values of 0.78 for the radial strains of both hearts and from an R 2 = 0.81 and R 2 = 0.83 for the circumferential strains. he strain predictions were not statistically different ( P ≤ 0.01 ) . A series of sensitivity results indicated that the methodology was relatively insensitive to alterations in image intensity, random image noise, and alterations in fiber structure. his study demonstrated that warping was able to provide strain predictions of systolic contraction of the LV consistent with those provided by tagged MRI Warping.« less
Mata, Marcia M; da Silva, Wladimir P; Wilson, Richard; Lowe, Edwin; Bowman, John P
2015-02-06
Contamination of industrial and domestic food usage environments by the attachement of bacterial food-borne pathogen Listeria monocytogenes has public health and economic implications. Comprehensive proteomics experiments using label-free liquid chromatography/tandem mass spectrometry were used to compare the proteomes of two different L. monocytogenes strains (Siliken_1/2c and F2365_4b), which show very different capacities to attach to surfaces. Growth temperature and strain type were highly influential on the proteomes in both attached and planktonic cells. On the basis of the proteomic data, it is highly unlikely that specific surface proteins play a direct role in adherence to inanimate surfaces. Instead, strain-dependent responses related to cell envelope polymer biosynthesis and stress response regulation likely contribute to a different ability to attach and also to survive external stressors. Collectively, the divergent proteome-level responses observed define strain- and growth-temperature-dependent differences relevant to attachment efficacy, highlight relevant proteins involved in stress protection in attached cells, and suggest that strain differences and growth conditions are important in relation to environmental persistence.
Steinemann, Daniel C.; Zerz, Andreas; Müller, Philip C.; Sauer, Peter; Schaible, Anja; Lasitschka, Felix; Schwarz, Anne-Catherine; Müller-Stich, Beat P.; Linke, Georg R.
2018-01-01
Background and study aims Extensive endoscopic mucosal resection (EMR) for Barrett’s esophagus (BE) may lead to stenosis. Laparoscopic, transgastric, stapler-assisted mucosectomy (SAM) retrieving circumferential specimens is proposed. Methods SAM was evaluated in two phases. The feasibility of SAM and the quality of specimens was assessed in eight animals. The mucosal healing was evaluated in a 6-weeks survival experiment comparing SAM (n=6) and EMR (n=6). The ratio of the esophageal lumen width (REL) at the resection level measured in fluoroscopy after 6-weeks divided by the width immediately after resection was compared. Results In all animals a circular mucosectomy specimen was successfully obtained with an area of 492(426-573)mm2 and 941(813-1209)mm2 using a 21-mm and 25-mm stapler, respectively. In the survival experiments two animals developed symptomatic stenosis after EMR and none after SAM. The REL was 0.27[0.18-0.39] and 0.96[0.9-1.04] (p<0.0001) for EMR and SAM, respectively. Conclusions SAM provides a novel technique for en-bloc mucosectomy in BE. In contrast to EMR mucosal healing in SAM was not associated with stenosis up to six weeks after intervention. PMID:28301879
Tang, Dalin; Del Nido, Pedro J; Yang, Chun; Zuo, Heng; Huang, Xueying; Rathod, Rahul H; Gooty, Vasu; Tang, Alexander; Wu, Zheyang; Billiar, Kristen L; Geva, Tal
2016-01-01
Accurate calculation of ventricular stress and strain is critical for cardiovascular investigations. Sarcomere shortening in active contraction leads to change of ventricular zero-stress configurations during the cardiac cycle. A new model using different zero-load diastole and systole geometries was introduced to provide more accurate cardiac stress/strain calculations with potential to predict post pulmonary valve replacement (PVR) surgical outcome. Cardiac magnetic resonance (CMR) data were obtained from 16 patients with repaired tetralogy of Fallot prior to and 6 months after pulmonary valve replacement (8 male, 8 female, mean age 34.5 years). Patients were divided into Group 1 (n = 8) with better post PVR outcome and Group 2 (n = 8) with worse post PVR outcome based on their change in RV ejection fraction (EF). CMR-based patient-specific computational RV/LV models using one zero-load geometry (1G model) and two zero-load geometries (diastole and systole, 2G model) were constructed and RV wall thickness, volume, circumferential and longitudinal curvatures, mechanical stress and strain were obtained for analysis. Pairwise T-test and Linear Mixed Effect (LME) model were used to determine if the differences from the 1G and 2G models were statistically significant, with the dependence of the pair-wise observations and the patient-slice clustering effects being taken into consideration. For group comparisons, continuous variables (RV volumes, WT, C- and L- curvatures, and stress and strain values) were summarized as mean ± SD and compared between the outcome groups by using an unpaired Student t-test. Logistic regression analysis was used to identify potential morphological and mechanical predictors for post PVR surgical outcome. Based on results from the 16 patients, mean begin-ejection stress and strain from the 2G model were 28% and 40% higher than that from the 1G model, respectively. Using the 2G model results, RV EF changes correlated negatively with stress
A curated database of cyanobacterial strains relevant for modern taxonomy and phylogenetic studies.
Ramos, Vitor; Morais, João; Vasconcelos, Vitor M
2017-04-25
The dataset herein described lays the groundwork for an online database of relevant cyanobacterial strains, named CyanoType (http://lege.ciimar.up.pt/cyanotype). It is a database that includes categorized cyanobacterial strains useful for taxonomic, phylogenetic or genomic purposes, with associated information obtained by means of a literature-based curation. The dataset lists 371 strains and represents the first version of the database (CyanoType v.1). Information for each strain includes strain synonymy and/or co-identity, strain categorization, habitat, accession numbers for molecular data, taxonomy and nomenclature notes according to three different classification schemes, hierarchical automatic classification, phylogenetic placement according to a selection of relevant studies (including this), and important bibliographic references. The database will be updated periodically, namely by adding new strains meeting the criteria for inclusion and by revising and adding up-to-date metadata for strains already listed. A global 16S rDNA-based phylogeny is provided in order to assist users when choosing the appropriate strains for their studies.
Vosen, Sarah; Rieck, Sarah; Heidsieck, Alexandra; Mykhaylyk, Olga; Zimmermann, Katrin; Plank, Christian; Gleich, Bernhard; Pfeifer, Alexander; Fleischmann, Bernd K; Wenzel, Daniela
2016-11-10
Gene therapy is a promising approach for chronic disorders that require continuous treatment such as cardiovascular disease. Overexpression of vasoprotective genes has generated encouraging results in animal models, but not in clinical trials. One major problem in humans is the delivery of sufficient amounts of genetic vectors to the endothelium which is impeded by blood flow, whereas prolonged stop-flow conditions impose the risk of ischemia. In the current study we have therefore developed a strategy for the efficient circumferential lentiviral gene transfer in the native endothelium under constant flow conditions. For that purpose we perfused vessels that were exposed to specially designed magnetic fields with complexes of lentivirus and magnetic nanoparticles thereby enabling overexpression of therapeutic genes such as endothelial nitric oxide synthase (eNOS) and vascular endothelial growth factor (VEGF). This treatment enhanced NO and VEGF production in the transduced endothelium and resulted in a reduction of vascular tone and increased angiogenesis. Thus, the combination of MNPs with magnetic fields is an innovative strategy for site-specific and efficient vascular gene therapy. Copyright © 2016 Elsevier B.V. All rights reserved.
Chiu, Yen-Chun; Yang, Shih-Chieh; Chen, Hung-Shu; Kao, Yu-Hsien; Tu, Yuan-Kun
2015-02-10
Complications and failure of vertebroplasty, such as cement dislodgement, cement leakage, or spinal infection, usually result in spinal instability and neural element compression. Combined anterior and posterior approaches are the most common salvage procedure for symptomatic failed vertebroplasty. The purpose of this study is to evaluate the feasibility and efficacy of a single posterior approach technique for the treatment of patients with symptomatic failed vertebroplasty. Ten patients with symptomatic failed vertebroplasty underwent circumferential debridement and anterior reconstruction surgery through a single-stage posterior transpedicular approach (PTA) from January 2009 to December 2011 at our institution. The differences of visual analog scale (VAS), neurologic status, and vertebral body reconstruction before and after surgery were recorded. The clinical outcomes of patients were categorized as excellent, good, fair, or poor based on modified Brodsky's criteria. The symptomatic failed vertebroplasty occurred between the T11 and L3 vertebrae with one- or two-level involvement. The average VAS score was 8.3 (range, 7 to 9) before surgery, significantly decreased to 3.2 (range, 2 to 4) after surgery (p < 0.01), and continued to decrease to 2.4 (range, 2 to 3) 1 year later (p < 0.01). The average correction of Cobb's angle after surgery was 17.3° (range, 4° to 35°) (p < 0.01). The mean loss of Cobb's angle correction after 1 year of follow-up was 2.7° (range, 0° to 5°). The average allograft subsidence at 1 year after surgery was 1 mm (range, 0 to 2). The neurologic status of Frankel's scale significantly improved after surgery (p = 0.014) and at 1 year after surgery (p = 0.046). No one experienced severe complications such as deep wound infection or neurologic deterioration. All patients achieved good or excellent outcomes after surgery based on modified Brodsky's criteria (p < 0.01). Single-stage PTA surgery with
Global tectonic reconstructions with continuously deforming and evolving rigid plates
NASA Astrophysics Data System (ADS)
Gurnis, Michael; Yang, Ting; Cannon, John; Turner, Mark; Williams, Simon; Flament, Nicolas; Müller, R. Dietmar
2018-07-01
Traditional plate reconstruction methodologies do not allow for plate deformation to be considered. Here we present software to construct and visualize global tectonic reconstructions with deforming plates within the context of rigid plates. Both deforming and rigid plates are defined by continuously evolving polygons. The deforming regions are tessellated with triangular meshes such that either strain rate or cumulative strain can be followed. The finite strain history, crustal thickness and stretching factor of points within the deformation zones are tracked as Lagrangian points. Integrating these tools within the interactive platform GPlates enables specialized users to build and refine deforming plate models and integrate them with other models in time and space. We demonstrate the integrated platform with regional reconstructions of Cenozoic western North America, the Mesozoic South American Atlantic margin, and Cenozoic southeast Asia, embedded within global reconstructions, using different data and reconstruction strategies.
Haendiges, Julie; Timme, Ruth; Allard, Marc W.; Myers, Robert A.; Brown, Eric W.; Gonzalez-Escalona, Narjol
2015-01-01
Vibrio parahaemolyticus is the leading cause of foodborne illnesses in the US associated with the consumption of raw shellfish. Previous population studies of V. parahaemolyticus have used Multi-Locus Sequence Typing (MLST) or Pulsed Field Gel Electrophoresis (PFGE). Whole genome sequencing (WGS) provides a much higher level of resolution, but has been used to characterize only a few United States (US) clinical isolates. Here we report the WGS characterization of 34 genomes of V. parahaemolyticus strains that were isolated from clinical cases in the state of Maryland (MD) during 2 years (2012–2013). These 2 years saw an increase of V. parahaemolyticus cases compared to previous years. Among these MD isolates, 28% were negative for tdh and trh, 8% were tdh positive only, 11% were trh positive only, and 53% contained both genes. We compared this set of V. parahaemolyticus genomes to those of a collection of 17 archival strains from the US (10 previously sequenced strains and 7 from NCBI, collected between 1988 and 2004) and 15 international strains, isolated from geographically-diverse environmental and clinical sources (collected between 1980 and 2010). A WGS phylogenetic analysis of these strains revealed the regional outbreak strains from MD are highly diverse and yet genetically distinct from the international strains. Some MD strains caused outbreaks 2 years in a row, indicating a local source of contamination (e.g., ST631). Advances in WGS will enable this type of analysis to become routine, providing an excellent tool for improved surveillance. Databases built with phylogenetic data will help pinpoint sources of contamination in future outbreaks and contribute to faster outbreak control. PMID:25745421
Nguyen, Cathy; Cone, Frances E.; Nguyen, Thao D.; Coudrillier, Baptiste; Pease, Mary E.; Steinhart, Matthew R.; Oglesby, Ericka N.; Jefferys, Joan L.; Quigley, Harry A.
2013-01-01
Purpose. To study anatomical changes and mechanical behavior of the sclera in mice with experimental glaucoma by comparing CD1 to B6 mice. Methods. Chronic experimental glaucoma for 6 weeks was produced in 2- to 4-month-old CD1 (43 eyes) and B6 mice (42 eyes) using polystyrene bead injection into the anterior chamber with 126 control CD1 and 128 control B6 eyes. Intraocular pressure (IOP) measurements were made with the TonoLab at baseline and after bead injection. Axial length and scleral thickness were measured after sacrifice in the CD1 and B6 animals and compared to length data from 78 eyes of DBA/2J mice. Inflation testing of posterior sclera was conducted, and circumferential and meridional strain components were determined from the displacement response. Results. Experimental glaucoma led to increases in axial length and width by comparison to fellow eyes (6% in CD1 and 10% in B6; all P < 0.03). While the peripapillary sclera became thinner in both mouse types with glaucoma, the remainder of the sclera uniformly thinned in CD1, but thickened in B6. Peripapillary sclera in CD1 controls had significantly greater temporal meridional strain than B6 and had differences in the ratios of meridional to effective circumferential strain from B6 mice. In both CD1 and B6 mice, exposure to chronic IOP elevation resulted in stiffer pressure–strain responses for both the effective circumferential and meridional strains (multivariable regression model, P = 0.01–0.03). Conclusions. Longer eyes, greater scleral strain in some directions at baseline, and generalized scleral thinning after glaucoma were characteristic of CD1 mice that have greater tendency to retinal ganglion cell damage than B6 mice. Increased scleral stiffness after glaucoma exposure in mice mimics findings in monkey and human glaucoma eyes. PMID:23404116
Thattaliyath, Bijoy D; Forsha, Daniel E; Stewart, Chad; Barker, Piers C A; Campbell, Michael J
2015-01-01
The aim of the study was to determine right and left ventricle deformation parameters in patients with transposition of the great arteries who had undergone atrial or arterial switch procedures. Patients with transposition are born with a systemic right ventricle. Historically, the atrial switch operation, in which the right ventricle remains the systemic ventricle, was performed. These patients have increased rates of morbidity and mortality. We used cardiac MRI with Velocity Vector Imaging analysis to characterize and compare ventricular myocardial deformation in patients who had an atrial switch or arterial switch operation. Patients with a history of these procedures, who had a clinically ordered cardiac MRI were included in the study. Consecutive 20 patients (75% male, 28.7 ± 1.8 years) who underwent atrial switch operation and 20 patients (60% male, 17.7 ± 1.9 years) who underwent arterial switch operation were included in the study. Four chamber and short-axis cine images were used to determine longitudinal and circumferential strain and strain rate using Vector Velocity Imaging software. Compared with the arterial switch group, the atrial switch group had decreased right ventricular ejection fraction and increased end-diastolic and end-systolic volumes, and no difference in left ventricular ejection fraction and volumes. The atrial switch group had decreased longitudinal and circumferential strain and strain rate. When compared with normal controls multiple strain parameters in the atrial switch group were reduced. Myocardial deformation analysis of transposition patients reveals a reduction of right ventricular function and decreased longitudinal and circumferential strain parameters in patients with an atrial switch operation compared with those with arterial switch operation. A better understanding of the mechanisms of right ventricle failure in transposition of great arteries may lead to improved therapies and adaptation. © 2015 Wiley Periodicals
Spatially distributed modal signals of free shallow membrane shell structronic system
NASA Astrophysics Data System (ADS)
Yue, H. H.; Deng, Z. Q.; Tzou, H. S.
2008-11-01
Based on the smart material and structronics technology, distributed sensor and control of shell structures have been rapidly developed for the last 20 years. This emerging technology has been utilized in aerospace, telecommunication, micro-electromechanical systems and other engineering applications. However, distributed monitoring technique and its resulting global spatially distributed sensing signals of shallow paraboloidal membrane shells are not clearly understood. In this paper, modeling of free flexible paraboloidal shell with spatially distributed sensor, micro-sensing signal characteristics, and location of distributed piezoelectric sensor patches are investigated based on a new set of assumed mode shape functions. Parametric analysis indicates that the signal generation depends on modal membrane strains in the meridional and circumferential directions in which the latter is more significant than the former, when all bending strains vanish in membrane shells. This study provides a modeling and analysis technique for distributed sensors laminated on lightweight paraboloidal flexible structures and identifies critical components and regions that generate significant signals.
Spatial Signal Characteristics of Shallow Paraboloidal Shell Structronic Systems
NASA Astrophysics Data System (ADS)
Yue, H. H.; Deng, Z. Q.; Tzou, H. S.
Based on the smart material and structronics technology, distributed sensor and control of shell structures have been rapidly developed for the last twenty years. This emerging technology has been utilized in aerospace, telecommunication, micro-electromechanical systems and other engineering applications. However, distributed monitoring technique and its resulting global spatially distributed sensing signals of thin flexible membrane shells are not clearly understood. In this paper, modeling of free thin paraboloidal shell with spatially distributed sensor, micro-sensing signal characteristics, and location of distributed piezoelectric sensor patches are investigated based on a new set of assumed mode shape functions. Parametric analysis indicates that the signal generation depends on modal membrane strains in the meridional and circumferential directions in which the latter is more significant than the former, when all bending strains vanish in membrane shells. This study provides a modeling and analysis technique for distributed sensors laminated on lightweight paraboloidal flexible structures and identifies critical components and regions that generate significant signals.
Abnormal Strain Rate Sensitivity Driven by a Unit Dislocation-Obstacle Interaction in bcc Fe
NASA Astrophysics Data System (ADS)
Bai, Zhitong; Fan, Yue
2018-03-01
The interaction between an edge dislocation and a sessile vacancy cluster in bcc Fe is investigated over a wide range of strain rates from 108 down to 103 s-1 , which is enabled by employing an energy landscape-based atomistic modeling algorithm. It is observed that, at low strain rates regime less than 105 s-1 , such interaction leads to a surprising negative strain rate sensitivity behavior because of the different intermediate microstructures emerged under the complex interplays between thermal activation and applied strain rate. Implications of our findings regarding the previously established global diffusion model are also discussed.
NASA Astrophysics Data System (ADS)
Wittek, Andreas; Blase, Christopher; Derwich, Wojciech; Schmitz-Rixen, Thomas; Fritzen, Claus-Peter
2017-06-01
Abdominal aortic aneurysms (AAA) are a degenerative disease of the human aortic wall that may lead to weakening and eventually rupture of the wall with high mortality rates. Since the currently established criterion for surgical or endovascular treatment of the disease is imprecise in the individual case and treatment is not free of complications, the need for additional patient-individual biomarkers for short-term AAA rupture risk as basis for improved clinical decision making. Time resolved 3D ultrasound combined with speckle tracking algorithms is a novel non-invasive medical imaging technique that provides full-field displacement and strain measurements of aortic and aneurysmal wall motion. This is patient-individual information that has not been used so far to assess wall strength and rupture risk. The current study uses simple statistical indices of the heterogeneous spatial distribution of in-plane strain components as biomarkers for the pathological state of the aortic and aneurysmal wall. The pathophysiological rationale behind this approach are the known changes in microstructural composition of the aortic wall with progression of AAA development that results in increased stiffening and heterogeneity of the walls mechanical properties and in decreased wall strength. In a comparative analysis of the aortic wall motion of young volunteers without known cardiovascular diseases, aged arteriosclerotic patients without AAA, and AAA patients, mean values of all in-plane strain components were significantly reduced, and the heterogeneity of circumferential strain was significantly increased in the AAA group compared to both other groups. The capacity of the proposed method to differentiate between wall motion of aged, arteriosclerotic patients and AAA patients is a promising step towards a new method for in vivo assessment of AAA wall strength or stratification of AAA rupture risk as basis for improved clinical decision making on surgical or endovascular
Cioffi, Giovanni; Viapiana, Ombretta; Ognibeni, Federica; Dalbeni, Andrea; Gatti, Davide; Mazzone, Carmine; Faganello, Giorgio; Di Lenarda, Andrea; Adami, Silvano; Rossini, Maurizio
2016-07-01
Patients with rheumatoid arthritis have an increased risk for cardiovascular disease. Because of accelerated atherosclerosis and changes in left ventricular (LV) geometry, circumferential and longitudinal (C&L) LV systolic dysfunction (LVSD) may be impaired in these patients despite preserved LV ejection fraction. The aim of this study was to determine the prevalence of and factors associated with combined C&L LVSD in patients with rheumatoid arthritis. One hundred ninety-eight outpatients with rheumatoid arthritis without overt cardiac disease were prospectively analyzed from January through June 2014 and compared with 198 matched control subjects. C&L systolic function was evaluated by stress-corrected midwall shortening (sc-MS) and tissue Doppler mitral annular peak systolic velocity (S'). Combined C&L LVSD was defined if sc-MS was <86.5% and S' was <9.0 cm/sec (the 10th percentiles of sc-MS and S' derived in 132 healthy subjects). Combined C&L LVSD was detected in 56 patients (28%) and was associated with LV mass (odds ratio, 1.03; 95% CI, 1.01-1.06; P = .04) and concentric LV geometry (odds ratio, 2.76; 95% CI, 1.07-7.15; P = .03). By multiple logistic regression analysis, rheumatoid arthritis emerged as an independent predictor of combined C&L LVSD (odds ratio, 2.57; 95% CI, 1.06-6.25). The relationship between sc-MS and S' was statistically significant in the subgroup of 142 patients without combined C&L LVSD (r = 0.40, F < 0.001), having the best fitting by a linear function (sc-MS = 58.1 + 3.34 × peak S'; r(2) = 0.19, P < .0001), absent in patients with combined C&L LVSD. Combined C&L LVSD is detectable in about one fourth of patients with asymptomatic rheumatoid arthritis and is associated with LV concentric remodeling and hypertrophy. Rheumatoid arthritis predicts this worrisome condition, which may explain the increased risk for cardiovascular events in these patients. The aim of this "notice of clarification" is to analyze in brief
A curated database of cyanobacterial strains relevant for modern taxonomy and phylogenetic studies
Ramos, Vitor; Morais, João; Vasconcelos, Vitor M.
2017-01-01
The dataset herein described lays the groundwork for an online database of relevant cyanobacterial strains, named CyanoType (http://lege.ciimar.up.pt/cyanotype). It is a database that includes categorized cyanobacterial strains useful for taxonomic, phylogenetic or genomic purposes, with associated information obtained by means of a literature-based curation. The dataset lists 371 strains and represents the first version of the database (CyanoType v.1). Information for each strain includes strain synonymy and/or co-identity, strain categorization, habitat, accession numbers for molecular data, taxonomy and nomenclature notes according to three different classification schemes, hierarchical automatic classification, phylogenetic placement according to a selection of relevant studies (including this), and important bibliographic references. The database will be updated periodically, namely by adding new strains meeting the criteria for inclusion and by revising and adding up-to-date metadata for strains already listed. A global 16S rDNA-based phylogeny is provided in order to assist users when choosing the appropriate strains for their studies. PMID:28440791
Chen, Qiang; Gan, Yan; Li, Zhi-Yong
2016-09-01
This study was to develop a strain analysis method to evaluate the left ventricular (LV) functions in type 2 diabetic patients with an asymptomatic LV diastolic dysfunction. Two groups (10 asymptomatic type 2 diabetic subjects and 10 control ones) were considered. All of the subjects had normal ejection fraction values but impaired diastolic functions assessed by the transmitral blood flow velocity. For each subject, based on cardiac MRI, global indexes including LV volume, LV myocardial mass, cardiac index (CI), and transmitral peak velocity, were measured, and regional indexes (i.e., LV deformation, strain and strain rate) were calculated through an image-registration technology. Most of the global indexes did not differentiate between the two groups, except for the CI, LV myocardial mass and transmitral peak velocity. While for the regional indexes, the global LV diastolic dysfunction of the diabetic indicated an increased strain (0.08 ± 0.044 vs. -0.031 ± 0.077, p = 0.001) and a reduced strain rate (1.834 ± 0.909 vs. 3.791 ± 2.394, p = 0.033) compared to the controls, moreover, the local LV diastolic dysfunction reflected by the strain and strain rate varied, and the degree of dysfunction gradually decreased from the basal level to the apical level. The results showed that the strain and strain rates are effective to capture the subtle alterations of the LV functions, and the proposed method can be used to estimate the LV myocardial function based on cardiac MRI.
Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem
2017-06-01
In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.
Global efforts in managing rice blast disease
USDA-ARS?s Scientific Manuscript database
Rice blast disease caused by the fungus Magnaporthe oryzae is a major destructive disease threatening global food security. Resistance (R) genes to M. oryzae are effective in preventing infections by strains of M. oryzae carry the corresponding avirulence (AVR) genes. Effectiveness of genetic resist...
Unique Abnormalities in Right Ventricular Longitudinal Strain in Systemic Sclerosis Patients.
Mukherjee, Monica; Chung, Shang-En; Ton, Von Khue; Tedford, Ryan J; Hummers, Laura K; Wigley, Fredrick M; Abraham, Theodore P; Shah, Ami A
2016-06-01
Cardiac involvement in systemic sclerosis (scleroderma [SSc]) adversely affects long-term prognosis, often remaining undetectable despite close clinical examination and 2-dimensional echocardiographic monitoring. Speckle-derived strain of the right ventricle (RV) was utilized to detect occult abnormalities in regional and global contractility in SSc patients. A total of 138 SSc patients with technically adequate echocardiograms was studied and compared with 40 age- and sex-matched healthy non-SSc controls. Standard assessment of RV chamber function included tricuspid annular plane systolic excursion and fractional area change. RV longitudinal systolic speckle-derived strain was assessed in the basal, mid, and apical free wall. Tricuspid annular plane systolic excursion was not different between groups (P=0.307). Although fractional area change was lower in SSc patients than in controls (mean, 48.9 versus 55; P=0.002), the mean fractional area change was still within the normal range (>35). In contrast, RV longitudinal systolic speckle-derived strain measures were significantly different between groups, both globally (-20.4% versus -17.7%; P=0.005) and regionally: they were decreased in the apex (-8.5% versus -17.1%; P<0.0001) and mid segments (-12.4% versus -20.9%; P<0.0001), and increased in the base (-32.2% versus -23.3%; P=0.0001) for the SSc group. The regional difference in the base compared with the apex was significantly greater for SSc than for controls (P<0.0001 for interaction). The differences observed in regional strain between SSc and control were unchanged after adjusting for RV systolic pressure. Speckle-derived strain reveals a heterogenous pattern of regional heart strain in SSc that is not detected by conventional measures of function, suggestive of occult RV myocardial disease. © 2016 American Heart Association, Inc.
Tang, Xin; Chen, Haiqin; Gu, Zhennan; Zhang, Hao; Chen, Yong Q; Song, Yuanda; Chen, Wei
2017-06-21
Mucor circinelloides is one of few oleaginous fungi that produces a useful oil rich in γ-linolenic acid, but it usually only produces <25% total lipid. Nevertheless, we isolated a new strain WJ11 that can produce up to 36% lipid of cell dry weight. In this study, we have systematically analyzed the global changes in protein levels between the high lipid-producing strain WJ11 and the low lipid-producing strain CBS 277.49 (15%, lipid/cell dry weight) at lipid accumulation phase through comparative proteome analysis. Proteome analysis demonstrated that the branched-chain amino acid and lysine metabolism, glycolytic pathway, and pentose phosphate pathway in WJ11 were up-regulated, while the activities of tricarboxylic acid cycle and branch point enzyme for synthesis of isoprenoids were retarded compared with CBS 277.49. The coordinated regulation at proteome level indicate that more acetyl-CoA and NADPH are provided for fatty acid biosynthesis in WJ11 compared with CBS 277.49.
Chen, Yan; Yeh, Anthony J; Cheung, Gordon Y C; Villaruz, Amer E; Tan, Vee Y; Joo, Hwang-Soo; Chatterjee, Som S; Yu, Yunsong; Otto, Michael
2015-02-01
Community-associated (CA) infections with methicillin-resistant Staphylococcus aureus (MRSA) are on a global rise. However, analysis of virulence characteristics has been limited almost exclusively to the US endemic strain USA300. CA-MRSA strains that do not produce Panton-Valentine leukocidin (PVL) have not been investigated on a molecular level. Therefore, we analyzed virulence determinants in a PVL-negative CA-MRSA strain, ST72, from Korea. Genome-wide analysis identified 3 loci that are unique to that strain, but did not affect virulence. In contrast, phenol-soluble modulins (PSMs) and the global virulence regulator Agr strongly affected lysis of neutrophils and erythrocytes, while α-toxin and Agr had a major impact on in vivo virulence. Our findings substantiate the general key roles these factors play in CA-MRSA virulence. However, our analyses also showed noticeable differences to strain USA300, inasmuch as α-toxin emerged as a much more important factor than PSMs in experimental skin infection caused by ST72. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Becker, Judith; Wittmann, Christoph
2012-10-01
With a world market of more than four million tons per year, l-amino acids are among the most important products in industrial biotechnology. The recent years have seen a tremendous progress in the development of tailor-made strains for such products, intensively driven from systems metabolic engineering, which upgrades strain engineering into a concept of optimization on a global scale. This concept seems especially valuable for efficient amino acid production, demanding for a global modification of pathway fluxes - a challenge with regard to the high complexity of the underlying metabolism, superimposed by various layers of metabolic and transcriptional control. Copyright © 2011 Elsevier Ltd. All rights reserved.
In-line inspection of unpiggable buried live gas pipes using circumferential EMAT guided waves
NASA Astrophysics Data System (ADS)
Ren, Baiyang; Xin, Junjun
2018-04-01
Unpiggable buried gas pipes need to be inspected to ensure their structural integrity and safe operation. The CIRRIS XITM robot, developed and operated by ULC Robotics, conducts in-line nondestructive inspection of live gas pipes. With the no-blow launching system, the inspection operation has reduced disruption to the public and by eliminating the need to dig trenches, has minimized the site footprint. This provides a highly time and cost effective solution for gas pipe maintenance. However, the current sensor on the robot performs a point-by-point measurement of the pipe wall thickness which cannot cover the whole volume of the pipe in a reasonable timeframe. The study of ultrasonic guided wave technique is discussed to improve the volume coverage as well as the scanning speed. Circumferential guided wave is employed to perform axial scanning. Mode selection is discussed in terms of sensitivity to different defects and defect characterization capability. To assist with the mode selection, finite element analysis is performed to evaluate the wave-defect interaction and to identify potential defect features. Pulse-echo and through-transmission mode are evaluated and compared for their pros and cons in axial scanning. Experiments are also conducted to verify the mode selection and detect and characterize artificial defects introduced into pipe samples.
de Amorim Corrêa, Ricardo; de Oliveira, Fernanda Brito; Barbosa, Marcia M; Barbosa, Jose Augusto A; Carvalho, Taís Soares; Barreto, Michele Campos; Campos, Frederico Thadeu A F; Nunes, Maria Carmo Pereira
2016-09-01
Pulmonary arterial hypertension (PAH) is characterized by elevated mean pulmonary arterial pressure with abnormal right ventricular (RV) pressure overload that may alter left ventricular (LV) function. The aim of this study was to assess the impact of RV pressure overload on LV function in PAH patients using two-dimensional (2D) speckle tracking strain. The study enrolled 37 group 1 PAH patients and 38 age- and gender-matched healthy controls. LV longitudinal and radial 2D strains were measured with and without including the ventricular septum. Six-minute walk test (6MWT) and brain natriuretic peptide (BNP) levels were also obtained in patients with PAH. The mean age of patients was 46.4 ± 14.8 years, 76% women, and 16 patients (43%) had schistosomiasis. Sixteen patients (43%) were in WHO class III or IV under specific treatment for PAH. The overall 6MWT distance was 441 meters, and the BNP levels were 80 pg/mL. Patients with PAH more commonly presented with LV diastolic dysfunction and impairment of RV function when compared to controls. LV global longitudinal and radial strains were lower in patients than in controls (-17.9 ± 2.8 vs. -20.5 ± 1.9; P < 0.001 and 30.8 ± 10.5 vs. 49.8 ± 15.4; P < 0.001, respectively). After excluding septal values, LV longitudinal and radial strains remained lower in patients than in controls. The independent factors associated with global LV longitudinal strain were LV ejection fraction, RV fractional area change, and tricuspid annular systolic motion. This study showed impaired LV contractility in patients with PAH assessed by speckle tracking strain, irrespective of ventricular septal involvement. Global LV longitudinal strain was associated independently with RV fractional area change and tricuspid annular systolic motion, after adjustment for LV ejection fraction. © 2016, Wiley Periodicals, Inc.
Sengupta, Shantanu P; Bansal, Manish; Hofstra, Leonard; Sengupta, Partho P; Narula, Jagat
2017-01-01
The goal of this study was to evaluate the impact of pregnancy and labor on left ventricular (LV) myocardial mechanics using speckle tracking echocardiography (STE). Pregnancy is characterized by profound hormonal and hemodynamic alterations that directly or indirectly influence cardiac structure and function. However, the impact of these changes on left ventricular (LV) myocardial contractile function has not been fully elucidated. In this prospective, longitudinal study, 35 pregnant women underwent serial clinical and echocardiographic evaluation during each trimester and at labor. Two dimensional STE was performed to measure global LV longitudinal, circumferential and radial strain (GLS, GCS and GRS, respectively). Similar data obtained from 20 nulliparous, age-matched women were used as control. All strain values during pregnancy were adjusted for age and hemodynamic parameters. There was a progressive increase in heart rate, systolic and diastolic blood pressure, cardiac output and LV stroke-work during pregnancy. LV end-diastolic and end-systolic volumes also increased progressively but LV ejection fraction remained unaltered, except for slight reduction during the second trimester. Compared to the controls, GLS and GCS were reduced in the first trimester itself (GLS -22.39 ± 5.43 % vs. -18.66 ± 0.64 %, P 0.0002; GCS -20.84 ± 3.20 vs. -17.88 ± 0.09, P < 0.001) and remained so throughout the pregnancy and labor. In contrast, GRS showed an increase during pregnancy which peaked during the second trimester (24.18 ± 0.39 % vs. 18.06 ± 8.14 % in controls, P < 0.001). Alterations in loading conditions during pregnancy are associated with counterbalancing changes in the myocardial mechanics. LV longitudinal and circumferential strain are reduced whereas radial strain is increased. These counterbalancing changes serve to maintain overall LV ejection performance within a normal range and enable the maternal heart to meet
Park, Jae-Hyeong; Choi, Jin-Oh; Park, Seung Woo; Cho, Goo-Yeong; Oh, Jin Kyung; Lee, Jae-Hwan; Seong, In-Whan
2018-02-01
Right ventricular (RV) strain values by 2-dimensional strain echocardiography (STE) can be used as objective markers of RV systolic function. However, there is little data about normal reference RV strain values according to age and gender. We measured normal RV strain values by STE. RV strain values were analyzed from the digitally stored echocardiographic images from NORMAL (Normal echOcardiogRaphic diMensions and functions in KoreAn popuLation) study for the measurement of normal echocardiographic values performed in 23 Korean university hospitals. We enrolled total 1003 healthy persons in the NORMAL study. Of them, we analyzed 2-dimensional RV strain values in 493 subjects (261 females, mean 47 ± 15 years old) only with echocardiographic images by GE machines. Their LV systolic and diastolic functions were normal. RV fractional area change was 48 ± 6% and tricuspid annular plane systolic excursion was 23 ± 3 mm. Total RV global longitudinal peak systolic strain (RVGLS total ) was -21.5 ± 3.2%. Females had higher absolute RVGLS total (-22.3 ± 3.3 vs -20.7 ± 2.9%, p < 0.001) than males. Younger (<50 years old) females had higher absolute RVGLS total (-22.9 ± 3.2 vs -20.5 ± 2.8%, p < 0.001) than age matched males. RVGLS total in females gradually increased according to age (p for trend = 0.002) and becomes almost similar in age ≥50 years. However, this trend was not seen in males (p for trend = 0.287), and younger males had similar RVGLS total value to that of older males (age ≥50 years, -20.5 ± 2.8 vs -20.9 ± 3.1%, p = 0.224). We calculated normal RVGLS values in normal population. Females have higher absolute strain values than males, especially in younger age groups (<50 years old).
The Global Economy--Policy Issues and Prospects.
ERIC Educational Resources Information Center
Laden, Ben E.
Economic policies of the industrial nations are on a dangerous course, constituting a threat to worldwide growth and to financial and economic stability. The results of inappropriate policies throughout the industrial countries are (1) financial strains which endanger global economic stability, (2) extraordinary imbalances of trade, and (3)…
Rapid intraplate strain accumulation in the New Madrid seismic zone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, L.; Zoback, M.D.; Segall, P.
1992-09-01
Remeasurement of a triangulation network in the southern part of the New Madrid seismic zone with the Global Positioning System has revealed rapid crustal strain accumulation since the 1950s. This area experienced three large (moment magnitudes greater than 8) earthquakes in 1811 to 1812. The orientation and sense of shear is consistent with right-lateral strike slip motion along a northeast-trending fault zone (as indicated by current seismicity). Detection of crustal strain accumulation may be a useful discriminant for identifying areas where potentially damaging intraplate earthquakes may occur despite the absence of large earthquakes during historic time. 34 refs.
Litzelman, Kristin; Skinner, Halcyon G; Gangnon, Ronald E; Nieto, F Javier; Malecki, Kristen; Witt, Whitney P
2014-06-01
Informal caregivers play a critical role in the care of individuals who are aging or have disabilities and are at increased risk for poor health outcomes. This study sought to determine whether and to what extent: (1) global stress and health-related quality of life (HRQoL) differed between caregivers and non-caregivers; (2) global stress mediated the relationship between caregiving status and HRQoL; and (3) caregiver strain (i.e., stress attributable to caregiving) was associated with worse HRQoL after accounting for global stress. Cross-sectional data were from the 2008-2010 Survey of the Health of Wisconsin, a representative sample of adults aged 21-74 years. Participants (n = 1,364) completed questionnaires about caregiving status, sociodemographics, global stress, and HRQoL. Staged generalized additive models assessed the impact of caregiving on HRQoL and the role of caregiver strain and global stress in this relationship. In the last 12 months, 17.2% of the sample reported caregiving. Caregivers reported worse mental HRQoL than non-caregivers (β -1.88, p = 0.02); global stress mediated this relationship (p < 0.01). Caregivers with the highest levels of strain reported worse mental and physical HRQoL (β -7.12, p < 0.01), and caregivers with the lowest levels of strain reported better mental HRQoL (β 2.06, p = 0.01) than non-caregivers; these associations were attenuated by global stress (p < 0.01). Global stress, rather than caregiving per se, contributes to poor HRQoL among caregivers, above and beyond the effect of caregiving strain. Screening, monitoring, and reducing stress in multiple life domains presents an opportunity to improve HRQoL outcomes for caregivers.
Beyhoff, Niklas; Brix, Sarah; Betz, Iris R; Klopfleisch, Robert; Foryst-Ludwig, Anna; Krannich, Alexander; Stawowy, Philipp; Knebel, Fabian; Grune, Jana; Kintscher, Ulrich
2017-12-01
The subendocardium is highly vulnerable to damage and is thus affected even in subclinical disease stages. Therefore, methods reflecting subendocardial status are of great clinical relevance for the early detection of cardiac damage and the prevention of functional impairment. The aim of this study was to investigate the potential ability of myocardial strain parameters to evaluate changes within the subendocardium. Male 129/Sv mice were injected with isoproterenol (ISO; n = 32) to induce isolated subendocardial fibrotic lesions or saline as appropriate control (n = 15). Transthoracic echocardiography was performed using a 30-MHz linear-frequency transducer coupled to a high-resolution imaging system, and acquired images were analyzed for conventional and strain parameters. The degree of collagen content within the different cardiac layers was quantified by histologic analysis and serum levels of tissue inhibitor of metalloproteinase-1, a biomarker for fibrosis, were assessed. ISO treatment induced a marked increase in subendocardial collagen content in response to cell loss (control vs ISO, 0.6 ± 0.3% vs 5.8 ± 0.9%; P < .001) and resulted in a moderate increase in left ventricular wall thickness with preserved systolic function. Global longitudinal peak strain (LS) and longitudinal strain rate were significantly decreased in ISO-treated animals (LS, -15.49% vs -11.49% [P = .001]; longitudinal strain rate, -4.81 vs -3.88 sec -1 [P < .05]), whereas radial and circumferential strain values remained unchanged. Global LS was associated with subendocardial collagen content (r = 0.46, P = .01) and tissue inhibitor of metalloproteinase-1 serum level (r = 0.52, P < .05). Further statistical analyses identified global LS as a superior predictor for the presence of subendocardial fibrosis (sensitivity, 84%; specificity, 80%; cutoff value, -14.4%). Assessment of LS may provide a noninvasive method for the detection of subendocardial damage and may
Revealing transient strain in geodetic data with Gaussian process regression
NASA Astrophysics Data System (ADS)
Hines, T. T.; Hetland, E. A.
2018-03-01
Transient strain derived from global navigation satellite system (GNSS) data can be used to detect and understand geophysical processes such as slow slip events and post-seismic deformation. Here we propose using Gaussian process regression (GPR) as a tool for estimating transient strain from GNSS data. GPR is a non-parametric, Bayesian method for interpolating scattered data. In our approach, we assume a stochastic prior model for transient displacements. The prior describes how much we expect transient displacements to covary spatially and temporally. A posterior estimate of transient strain is obtained by differentiating the posterior transient displacements, which are formed by conditioning the prior with the GNSS data. As a demonstration, we use GPR to detect transient strain resulting from slow slip events in the Pacific Northwest. Maximum likelihood methods are used to constrain a prior model for transient displacements in this region. The temporal covariance of our prior model is described by a compact Wendland covariance function, which significantly reduces the computational burden that can be associated with GPR. Our results reveal the spatial and temporal evolution of strain from slow slip events. We verify that the transient strain estimated with GPR is in fact geophysical signal by comparing it to the seismic tremor that is associated with Pacific Northwest slow slip events.
Castel, Anne-Laure; Menet, Aymeric; Ennezat, Pierre-Vladimir; Delelis, François; Le Goffic, Caroline; Binda, Camille; Guerbaai, Raphaëlle-Ashley; Levy, Franck; Graux, Pierre; Tribouilloy, Christophe; Maréchaux, Sylvestre
2016-01-01
Speckle tracking can be used to measure left ventricular global longitudinal strain (GLS). To study the effect of speckle tracking software product upgrades on GLS values and intervendor consistency. Subjects (patients or healthy volunteers) underwent systematic echocardiography with equipment from Philips and GE, without a change in their position. Off-line post-processing for GLS assessment was performed with the former and most recent upgrades from these two vendors (Philips QLAB 9.0 and 10.2; GE EchoPAC 12.1 and 13.1.1). GLS was obtained in three myocardial layers with EchoPAC 13.1.1. Intersoftware and intervendor consistency was assessed. Interobserver variability was tested in a subset of patients. Among 73 subjects (65 patients and 8 healthy volunteers), absolute values of GLS were higher with QLAB 10.2 compared with 9.0 (intraclass correlation coefficient [ICC]: 0.88; bias: 2.2%). Agreement between EchoPAC 13.1.1 and 12.1 varied by myocardial layer (13.1.1 only): midwall (ICC: 0.95; bias: -1.1%), endocardium (ICC: 0.93; bias: 1.6%) and epicardial (ICC: 0.80; bias: -3.3%). Although GLS was comparable for QLAB 9.0 versus EchoPAC 12.1 (ICC: 0.95; bias: 0.5%), the agreement was lower between QLAB 10.2 and EchoPAC 13.1.1 endocardial (ICC: 0.91; bias: 1.1%), midwall (ICC: 0.73; bias: 3.9%) and epicardial (ICC: 0.54; bias: 6.0%). Interobserver variability of all software products in a subset of 20 patients was excellent (ICC: 0.97-0.99; bias: -0.8 to 1.0%). Upgrades of speckle tracking software may be associated with significant changes in GLS values, which could affect intersoftware and intervendor consistency. This finding has important clinical implications for the longitudinal follow-up of patients with speckle tracking echocardiography. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Whole-genome comparative analysis of three phytopathogenic Xylella fastidiosa strains.
Bhattacharyya, Anamitra; Stilwagen, Stephanie; Ivanova, Natalia; D'Souza, Mark; Bernal, Axel; Lykidis, Athanasios; Kapatral, Vinayak; Anderson, Iain; Larsen, Niels; Los, Tamara; Reznik, Gary; Selkov, Eugene; Walunas, Theresa L; Feil, Helene; Feil, William S; Purcell, Alexander; Lassez, Jean-Louis; Hawkins, Trevor L; Haselkorn, Robert; Overbeek, Ross; Predki, Paul F; Kyrpides, Nikos C
2002-09-17
Xylella fastidiosa (Xf) causes wilt disease in plants and is responsible for major economic and crop losses globally. Owing to the public importance of this phytopathogen we embarked on a comparative analysis of the complete genome of Xf pv citrus and the partial genomes of two recently sequenced strains of this species: Xf pv almond and Xf pv oleander, which cause leaf scorch in almond and oleander plants, respectively. We report a reanalysis of the previously sequenced Xf 9a5c (CVC, citrus) strain and the two "gapped" Xf genomes revealing ORFs encoding critical functions in pathogenicity and conjugative transfer. Second, a detailed whole-genome functional comparison was based on the three sequenced Xf strains, identifying the unique genes present in each strain, in addition to those shared between strains. Third, an "in silico" cellular reconstruction of these organisms was made, based on a comparison of their core functional subsystems that led to a characterization of their conjugative transfer machinery, identification of potential differences in their adhesion mechanisms, and highlighting of the absence of a classical quorum-sensing mechanism. This study demonstrates the effectiveness of comparative analysis strategies in the interpretation of genomes that are closely related.
Rea, Domenica; Coppola, Carmela; Barbieri, Antonio; Monti, Maria Gaia; Misso, Gabriella; Palma, Giuseppe; Bimonte, Sabrina; Zarone, Mayra Rachele; Luciano, Antonio; Liccardo, Davide; Maiolino, Piera; Cittadini, Antonio; Ciliberto, Gennaro; Arra, Claudio; Maurea, Nicola
2016-01-01
In recent years, the development of more effective anticancer drugs has provided great benefits in patients' quality of life by improving both prognosis and disease-free survival. Nevertheless, the frequency and severity of side-effects, with particular reference to cardiac toxicity, have gained particular attention. The purpose of this study was to create a precise and sensitive preclinical model, able to identify early contractile dysfunction in mice treated with chemotherapy, through use of speckle-tracking echocardiography. We generated a mouse model of cardiotoxicity induced by doxorubicin. C57BL 6 mice were divided into two groups, treated for 7 days by intraperitoneal injections of placebo (vehicle) or doxorubicin (2.17 mg/kg), in order to characterize the cardiac phenotype in vivo. We demonstrated that doxorubicin caused ealy remodeling of the left ventricle: after two days of therapy, the radial, circumferential and strain rates were reduced respectively by 35%, 34%, and 39% (p-value ≤0.001). Moreover, histological analysis revealed that doxorubicin treatment increased fibrosis, cardiomyocyte diameter and apoptosis. In a murine model of doxorubicin-induced cardiac injury, we detected left ventricular dysfunction followed by alterations in conventional echocardiographic indices. Our study suggests that a change in strain could be an effective early marker of myocardial dysfunction for new anticancer treatments and, in preclinical studies, it might also be a valuable indicator for the assessment of activity of cardioprotective agents. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Global gene expression of Prochlorococcus ecotypes in response to changes in nitrogen availability
Tolonen, Andrew C; Aach, John; Lindell, Debbie; Johnson, Zackary I; Rector, Trent; Steen, Robert; Church, George M; Chisholm, Sallie W
2006-01-01
Nitrogen (N) often limits biological productivity in the oceanic gyres where Prochlorococcus is the most abundant photosynthetic organism. The Prochlorococcus community is composed of strains, such as MED4 and MIT9313, that have different N utilization capabilities and that belong to ecotypes with different depth distributions. An interstrain comparison of how Prochlorococcus responds to changes in ambient nitrogen is thus central to understanding its ecology. We quantified changes in MED4 and MIT9313 global mRNA expression, chlorophyll fluorescence, and photosystem II photochemical efficiency (Fv/Fm) along a time series of increasing N starvation. In addition, the global expression of both strains growing in ammonium-replete medium was compared to expression during growth on alternative N sources. There were interstrain similarities in N regulation such as the activation of a putative NtcA regulon during N stress. There were also important differences between the strains such as in the expression patterns of carbon metabolism genes, suggesting that the two strains integrate N and C metabolism in fundamentally different ways. PMID:17016519
NASA Technical Reports Server (NTRS)
Freed, Alan D.
1995-01-01
The purpose of this paper is to present a consistent and thorough development of the strain and strain-rate measures affiliated with Hencky. Natural measures for strain and strain-rate, as I refer to them, are first expressed in terms of of the fundamental body-metric tensors of Lodge. These strain and strain-rate measures are mixed tensor fields. They are mapped from the body to space in both the Eulerian and Lagrangian configurations, and then transformed from general to Cartesian fields. There they are compared with the various strain and strain-rate measures found in the literature. A simple Cartesian description for Hencky strain-rate in the Lagrangian state is obtained.
Litzelman, Kristin; Skinner, Halcyon G.; Gangnon, Ronald E.; Nieto, F. Javier; Malecki, Kristen; Witt, Whitney P.
2014-01-01
Purpose Informal caregivers play a critical role in the care of individuals who are aging or have disabilities, and are at increased risk for poor health outcomes. This study sought to determine if and to what extent: 1) global stress and health-related quality of life (HRQoL) differed between caregivers and non-caregivers; 2) global stress mediated the relationship between caregiving status and HRQoL; and 3) caregiver strain (i.e., stress attributable to caregiving) was associated with worse HRQoL after accounting for global stress. Methods Cross-sectional data were from the 2008–2010 Survey of the Health of Wisconsin (SHOW), a representative sample of adults aged 21–74 years. Participants (n=1,364) completed questionnaires about caregiving status, socio-demographics, global stress, and HRQoL. Staged generalized additive models assessed the impact of caregiving on HRQoL and the role of caregiver strain and global stress in this relationship. Results 17.2% of the sample reported caregiving in the last 12 months. Caregivers reported worse mental HRQoL than non-caregivers (Beta: −1.88, p=0.02); global stress mediated this relationship (p<0.01). Caregivers with the highest levels of strain reported worse mental and physical HRQoL (Beta: −7.12, p<0.01) and caregivers with the lowest levels of strain reported better mental HRQoL (Beta: 2.06, p=0.01) than non-caregivers; these associations were attenuated by global stress (p<0.01). Conclusion Global stress, rather than caregiving per se, contributes to poor HRQoL among caregivers, above and beyond the effect of caregiving strain. Screening, monitoring, and reducing stress in multiple life domains presents an opportunity to improve HRQoL outcomes for caregivers. PMID:24322907
Development of inactivated poliovirus vaccine from Sabin strains: A progress report.
Okayasu, Hiromasa; Sein, Carolyn; Hamidi, Ahd; Bakker, Wilfried A M; Sutter, Roland W
2016-11-01
The Global Polio Eradication Initiative (GPEI) has seen significant progress since it began in 1988, largely due to the worldwide use of oral poliovirus vaccine (OPV). In order to achieve polio eradication the global cessation of OPV is necessary because OPV contains live attenuated poliovirus, which in rare circumstances could re-gain wild poliovirus (WPV) characteristics with potential to establish transmission. The GPEI endgame strategy for the period 2013-2018 recommends the globally synchronised sequential cessation of the Sabin strains contained in the OPV, starting with type 2 Sabin. The withdrawal of Sabin type 2 took place in April 2016, with the introduction of at least one dose of inactivated poliovirus vaccine (IPV) as a risk mitigation strategy. The introduction of IPV into 126 countries since 2013 has required a rapid scale-up of IPV production by the two manufacturers supplying the global public sector market. This scale-up has been fraught with challenges, resulting in reductions of 40-50% of initial supply commitments. Consequently, 22 countries will not be supplied until 2018, and another 23 countries will experience serious stock-outs. In the last decade repeated calls-for-action were made to the global community to invigorate their vision and investment in developing "new poliovirus vaccines" including the development of IPV from less-virulent strains, such as Sabin-IPV (S-IPV). The conventional Salk-IPV production is limited to high-income industrialized-country manufacturers due to the containment requirements (i.e., high sanitation, low force-of-poliovirus-infection, and high population immunity). The use of Sabin strains in the production of S-IPV carries a lower biosafety risk, and was determined to be suitable for production in developing countries, expanding the manufacturing base and making IPV more affordable and accessible in the long term. Significant progress in the S-IPV has been made since 2006. S-IPV is now licensed as S-IPV in
Modin, Daniel; Sengeløv, Morten; Jørgensen, Peter Godsk; Bruun, Niels Eske; Olsen, Flemming Javier; Dons, Maria; Fritz Hansen, Thomas; Jensen, Jan Skov; Biering-Sørensen, Tor
2018-04-01
Quantification of systolic function in patients with atrial fibrillation (AF) is challenging. A novel approach, based on RR interval correction, to counteract the varying heart cycle lengths in AF has recently been proposed. Whether this method is superior in patients with systolic heart failure (HFrEF) with AF remains unknown. This study investigates the prognostic value of RR interval-corrected peak global longitudinal strain {GLSc = GLS/[RR^(1/2)]} in relation to all-cause mortality in HFrEF patients displaying AF during echocardiographic examination. Echocardiograms from 151 patients with HFrEF and AF during examination were analysed offline. Peak global longitudinal strain (GLS) was averaged from 18 myocardial segments obtained from three apical views. GLS was indexed with the square root of the RR interval {GLSc = GLS/[RR^(1/2)]}. Endpoint was all-cause mortality. During a median follow-up of 2.7 years, 40 patients (26.5%) died. Neither uncorrected GLS (P = 0.056) nor left ventricular ejection fraction (P = 0.053) was significantly associated with all-cause mortality. After RR^(1/2) indexation, GLSc became a significant predictor of all-cause mortality (hazard ratio 1.16, 95% confidence interval 1.02-1.22, P = 0.014, per %/s^(1/2) decrease). GLSc remained an independent predictor of mortality after multivariable adjustment (age, sex, mean heart rate, mean arterial blood pressure, left atrial volume index, and E/e') (hazard ratio 1.17, 95% confidence interval 1.05-1.31, P = 0.005 per %/s^(1/2) decrease). Decreasing {GLSc = GLS/[RR^(1/2)]}, but not uncorrected GLS nor left ventricular ejection fraction, was significantly associated with increased risk of all-cause mortality in HFrEF patients with AF and remained an independent predictor after multivariable adjustment. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.
NASA Astrophysics Data System (ADS)
Aldakheel, Fadi
2017-11-01
The coupled thermo-mechanical strain gradient plasticity theory that accounts for microstructure-based size effects is outlined within this work. It extends the recent work of Miehe et al. (Comput Methods Appl Mech Eng 268:704-734, 2014) to account for thermal effects at finite strains. From the computational viewpoint, the finite element design of the coupled problem is not straightforward and requires additional strategies due to the difficulties near the elastic-plastic boundaries. To simplify the finite element formulation, we extend it toward the micromorphic approach to gradient thermo-plasticity model in the logarithmic strain space. The key point is the introduction of dual local-global field variables via a penalty method, where only the global fields are restricted by boundary conditions. Hence, the problem of restricting the gradient variable to the plastic domain is relaxed, which makes the formulation very attractive for finite element implementation as discussed in Forest (J Eng Mech 135:117-131, 2009) and Miehe et al. (Philos Trans R Soc A Math Phys Eng Sci 374:20150170, 2016).
Tegos, Stergios; Charitidis, Charalampos; Korovessis, Panagiotis G
2014-04-01
Retrospective study on circumferential hybrid instrumentation with posterior lumbar interbody fusion (PLIF) and the novel posterior Universal Clamp (UC) instrumentation. This study evaluated the roentgenographic and clinical outcome after PLIF with PEEK cage augmented with UC posterior sublaminar fixation without posterior fusion. Although UC has been successfully used in scoliosis surgery, to our knowledge, this is the first report on its use in degenerative lumbosacral disease. Rigid pedicle screw lumbosacral fixation is associated with several intraoperative screw-related complications. The use of sublaminar bands and rods combined with PEEK PLIF should increase fusion rate and avoid screw-related complications. From a total of 295 consecutive patients who experienced degenerative lumbosacral disease and received posterior decompression, implantation of PLIF with PEEK cages and semirigid posterior fixation with sublaminar UC bands-rods without posterolateral fusion, 150 patients were eligible for this study with a follow-up of more than 2 years. Interbody fusion rate and global plus segmental sagittal spinal lordosis restoration were recorded pre- and postoperatively. Visual analogue scale and Oswestry Disability Index were used to assess functional outcome. Hybrid instrumentation expanded over 1 to 5 levels. Surgical time ranged from 45 to 225 minutes. Only 12.6% of the patients were transfused. There was no nerve root lesion or deep wound infection. Laminar fracture occurred intraoperatively in one case during band insertion. Interbody fusion was achieved in 94% of the operated segments. Lumbar lordosis improved from -36 ± 9° preoperatively to -53 ± 6° postoperatively. Segmental lordosis improved in L4-L5 segment from -5 ± 3° preoperatively to -12 ± 2° postoperatively and in L5-S1 from -9 ± 4° to -14 ± 2° postoperation. Oswestry Disability Index score improved from 44.9 preoperatively to 2.2 postoperatively (P < 0.001). No patient required further
Mirea, Oana; Pagourelias, Efstathios D; Duchenne, Jurgen; Bogaert, Jan; Thomas, James D; Badano, Luigi P; Voigt, Jens-Uwe
2018-01-01
In this study, we compared left ventricular (LV) segmental strain measurements obtained with different ultrasound machines and post-processing software packages. Global longitudinal strain (GLS) has proven to be a reproducible and valuable tool in clinical practice. Data about the reproducibility and intervendor differences of segmental strain measurements, however, are missing. We included 63 volunteers with cardiac magnetic resonance-proven infarct scar with segmental LV function ranging from normal to severely impaired. Each subject was examined within 2 h by a single expert sonographer with machines from multiple vendors. All 3 apical views were acquired twice to determine the test-retest and the intervendor variability. Segmental longitudinal peak systolic, end-systolic, and post-systolic strain were measured using 7 vendor-specific systems (Hitachi, Tokyo, Japan; Esaote, Florence, Italy; GE Vingmed Ultrasound, Horten, Norway; Philips, Andover, Massachusetts; Samsung, Seoul, South Korea; Siemens, Mountain View, California; and Toshiba, Otawara, Japan) and 2 independent software packages (Epsilon, Ann Arbor, Michigan; and TOMTEC, Unterschleissheim, Germany) and compared among vendors. Image quality and tracking feasibility differed among vendors (analysis of variance, p < 0.05). The absolute test-retest difference ranged from 2.5% to 4.9% for peak systolic, 2.6% to 5.0% for end-systolic, and 2.5% to 5.0% for post-systolic strain. The average segmental strain values varied significantly between vendors (up to 4.5%). Segmental strain parameters from each vendor correlated well with the mean of all vendors (r 2 range 0.58 to 0.81) but showed very different ranges of values. Bias and limits of agreement were up to -4.6 ± 7.5%. In contrast to GLS, LV segmental longitudinal strain measurements have a higher variability on top of the known intervendor bias. The fidelity of different software to follow segmental function varies considerably. We conclude that
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gefken, Paul; Curran, Donald; Nesterenko, Vitali F.
Two spherical cavity expansion experiments were performed with SiC-N to provide high-strain rate data for developing ceramic armor penetration models. Here, an explosive charge is detonated within a cavity machined in the ceramic, generating a pulse that moves radially outward. The particle velocity at multiple radial locations from the charge, including at the charge radii, was measured and the fractured ceramic was recovered for posttest evaluation. From the particle velocity histories we derived displacement, radial strain and circumferential strain histories. In the recovered samples we observed the regions where comminution, radial cracking and circumferential cracking occurred. The elastic properties ofmore » initial undamaged SiC-N and shocked damaged material were measured using a resonant ultrasound spectroscopy (RUS). Comparison of these measurements illustrated the posttest condition of the SiC-N material. Hot isostatic pressing of ''as is'' SiC-N material demonstrated a significant increase in the quality factor. The same procedure applied to SiC-N damaged in spherical cavity experiments resulted in a significant recovery of the elastic properties.« less
Global analysis of translation termination in E. coli.
Baggett, Natalie E; Zhang, Yan; Gross, Carol A
2017-03-01
Terminating protein translation accurately and efficiently is critical for both protein fidelity and ribosome recycling for continued translation. The three bacterial release factors (RFs) play key roles: RF1 and 2 recognize stop codons and terminate translation; and RF3 promotes disassociation of bound release factors. Probing release factors mutations with reporter constructs containing programmed frameshifting sequences or premature stop codons had revealed a propensity for readthrough or frameshifting at these specific sites, but their effects on translation genome-wide have not been examined. We performed ribosome profiling on a set of isogenic strains with well-characterized release factor mutations to determine how they alter translation globally. Consistent with their known defects, strains with increasingly severe release factor defects exhibit increasingly severe accumulation of ribosomes over stop codons, indicative of an increased duration of the termination/release phase of translation. Release factor mutant strains also exhibit increased occupancy in the region following the stop codon at a significant number of genes. Our global analysis revealed that, as expected, translation termination is generally efficient and accurate, but that at a significant number of genes (≥ 50) the ribosome signature after the stop codon is suggestive of translation past the stop codon. Even native E. coli K-12 exhibits the ribosome signature suggestive of protein extension, especially at UGA codons, which rely exclusively on the reduced function RF2 variant of the K-12 strain for termination. Deletion of RF3 increases the severity of the defect. We unambiguously demonstrate readthrough and frameshifting protein extensions and their further accumulation in mutant strains for a few select cases. In addition to enhancing recoding, ribosome accumulation over stop codons disrupts attenuation control of biosynthetic operons, and may alter expression of some overlapping genes
Global analysis of translation termination in E. coli
Baggett, Natalie E.
2017-01-01
Terminating protein translation accurately and efficiently is critical for both protein fidelity and ribosome recycling for continued translation. The three bacterial release factors (RFs) play key roles: RF1 and 2 recognize stop codons and terminate translation; and RF3 promotes disassociation of bound release factors. Probing release factors mutations with reporter constructs containing programmed frameshifting sequences or premature stop codons had revealed a propensity for readthrough or frameshifting at these specific sites, but their effects on translation genome-wide have not been examined. We performed ribosome profiling on a set of isogenic strains with well-characterized release factor mutations to determine how they alter translation globally. Consistent with their known defects, strains with increasingly severe release factor defects exhibit increasingly severe accumulation of ribosomes over stop codons, indicative of an increased duration of the termination/release phase of translation. Release factor mutant strains also exhibit increased occupancy in the region following the stop codon at a significant number of genes. Our global analysis revealed that, as expected, translation termination is generally efficient and accurate, but that at a significant number of genes (≥ 50) the ribosome signature after the stop codon is suggestive of translation past the stop codon. Even native E. coli K-12 exhibits the ribosome signature suggestive of protein extension, especially at UGA codons, which rely exclusively on the reduced function RF2 variant of the K-12 strain for termination. Deletion of RF3 increases the severity of the defect. We unambiguously demonstrate readthrough and frameshifting protein extensions and their further accumulation in mutant strains for a few select cases. In addition to enhancing recoding, ribosome accumulation over stop codons disrupts attenuation control of biosynthetic operons, and may alter expression of some overlapping genes
Enzensberger, Christian; Achterberg, Friederike; Graupner, Oliver; Wolter, Aline; Herrmann, Johannes; Axt-Fliedner, Roland
2017-06-01
Frame rates (FR) used for strain analysis assessed by speckle tracking in fetal echocardiography show a considerable variation. The aim of this study was to investigate the influence of the FR on strain analysis in 2D speckle tracking. Fetal echocardiography was performed prospectively on a Toshiba Aplio 500 system and a Toshiba Artida system, respectively. Based on an apical or basal four-chamber view of the fetal heart, cine loops were stored with a FR of 30 fps (Aplio 500) and 60 fps (Artida/Aplio 500). For both groups (30fps and 60fps), global and segmental longitudinal peak systolic strain (LPSS) values of both, left (LV) and right ventricle (RV), were assessed by 2D wall-motion tracking. A total of 101 fetuses, distributed to three study groups, were included. The mean gestational age was 25.2±5.0 weeks. Mean global LPSS values for RV in the 30 fps group and in the 60 fps group were -16.07% and -16.47%, respectively. Mean global LPSS values for LV in the 30 fps group and in the 60 fps group were -17.54% and -17.06%, respectively. Comparing global and segmental LPSS values of both, the RV and LV, did not show any statistically significant differences within the two groups. Performance of myocardial 2D strain analysis by wall-motion tracking was feasible with 30 and 60 fps. Obtained global and segmental LPSS values of both ventricles were relatively independent from acquisition rate. © 2017, Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Freed, Alan D.
1997-01-01
Logarithmic strain is the preferred measure of strain used by materials scientists, who typically refer to it as the "true strain." It was Nadai who gave it the name "natural strain," which seems more appropriate. This strain measure was proposed by Ludwik for the one-dimensional extension of a rod with length l. It was defined via the integral of dl/l to which Ludwik gave the name "effective specific strain." Today, it is after Hencky, who extended Ludwik's measure to three-dimensional analysis by defining logarithmic strains for the three principal directions.
Brunenders: a partially attenuated historic poliovirus type I vaccine strain.
Sanders, Barbara P; Liu, Ying; Brandjes, Alies; van Hoek, Vladimir; de Los Rios Oakes, Isabel; Lewis, John; Wimmer, Eckard; Custers, Jerome H H V; Schuitemaker, Hanneke; Cello, Jeronimo; Edo-Matas, Diana
2015-09-01
Brunenders, a type I poliovirus (PV) strain, was developed in 1952 by J. F. Enders and colleagues through serial in vitro passaging of the parental Brunhilde strain, and was reported to display partial neuroattenuation in monkeys. This phenotype of attenuation encouraged two vaccine manufacturers to adopt Brunenders as the type I component for their inactivated poliovirus vaccines (IPVs) in the 1950s, although today no licensed IPV vaccine contains Brunenders. Here we confirmed, in a transgenic mouse model, the report of Enders on the reduced neurovirulence of Brunenders. Although dramatically neuroattenuated relative to WT PV strains, Brunenders remains more virulent than the attenuated oral vaccine strain, Sabin 1. Importantly, the neuroattenuation of Brunenders does not affect in vitro growth kinetics and in vitro antigenicity, which were similar to those of Mahoney, the conventional type I IPV vaccine strain. We showed, by full nucleotide sequencing, that Brunhilde and Brunenders differ at 31 nucleotides, eight of which lead to amino acid changes, all located in the capsid. Upon exchanging the Brunenders capsid sequence with that of the Mahoney capsid, WT neurovirulence was regained in vivo, suggesting a role for the capsid mutations in Brunenders attenuation. To date, as polio eradication draws closer, the switch to using attenuated strains for IPV is actively being pursued. Brunenders preceded this novel strategy as a partially attenuated IPV strain, accompanied by decades of successful use in the field. Providing data on the attenuation of Brunenders may be of value in the further construction of attenuated PV strains to support the grand pursuit of the global eradication of poliomyelitis.
Farsalinos, Konstantinos E; Daraban, Ana M; Ünlü, Serkan; Thomas, James D; Badano, Luigi P; Voigt, Jens-Uwe
2015-10-01
This study was planned by the EACVI/ASE/Industry Task Force to Standardize Deformation Imaging to (1) test the variability of speckle-tracking global longitudinal strain (GLS) measurements among different vendors and (2) compare GLS measurement variability with conventional echocardiographic parameters. Sixty-two volunteers were studied using ultrasound systems from seven manufacturers. Each volunteer was examined by the same sonographer on all machines. Inter- and intraobserver variability was determined in a true test-retest setting. Conventional echocardiographic parameters were acquired for comparison. Using the software packages of the respective manufacturer and of two software-only vendors, endocardial GLS was measured because it was the only GLS parameter that could be provided by all manufactures. We compared GLSAV (the average from the three apical views) and GLS4CH (measured in the four-chamber view) measurements among vendors and with the conventional echocardiographic parameters. Absolute values of GLSAV ranged from 18.0% to 21.5%, while GLS4CH ranged from 17.9% to 21.4%. The absolute difference between vendors for GLSAV was up to 3.7% strain units (P < .001). The interobserver relative mean errors were 5.4% to 8.6% for GLSAV and 6.2% to 11.0% for GLS4CH, while the intraobserver relative mean errors were 4.9% to 7.3% and 7.2% to 11.3%, respectively. These errors were lower than for left ventricular ejection fraction and most other conventional echocardiographic parameters. Reproducibility of GLS measurements was good and in many cases superior to conventional echocardiographic measurements. The small but statistically significant variation among vendors should be considered in performing serial studies and reflects a reference point for ongoing standardization efforts. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Guo, Ning; Yang, Zhichun; Wang, Le; Ouyang, Yan; Zhang, Xinping
2018-05-01
Aiming at providing a precise dynamic structural finite element (FE) model for dynamic strength evaluation in addition to dynamic analysis. A dynamic FE model updating method is presented to correct the uncertain parameters of the FE model of a structure using strain mode shapes and natural frequencies. The strain mode shape, which is sensitive to local changes in structure, is used instead of the displacement mode for enhancing model updating. The coordinate strain modal assurance criterion is developed to evaluate the correlation level at each coordinate over the experimental and the analytical strain mode shapes. Moreover, the natural frequencies which provide the global information of the structure are used to guarantee the accuracy of modal properties of the global model. Then, the weighted summation of the natural frequency residual and the coordinate strain modal assurance criterion residual is used as the objective function in the proposed dynamic FE model updating procedure. The hybrid genetic/pattern-search optimization algorithm is adopted to perform the dynamic FE model updating procedure. Numerical simulation and model updating experiment for a clamped-clamped beam are performed to validate the feasibility and effectiveness of the present method. The results show that the proposed method can be used to update the uncertain parameters with good robustness. And the updated dynamic FE model of the beam structure, which can correctly predict both the natural frequencies and the local dynamic strains, is reliable for the following dynamic analysis and dynamic strength evaluation.
Pirat, Bahar; Bozbas, Huseyin; Simsek, Vahide; Sade, L Elif; Sayin, Burak; Muderrisoglu, Haldun; Haberal, Mehmet
2015-04-01
Velocity vector imaging allows quantitation of myocardial strain and strain rate from 2-dimensional images based on speckle tracking echocardiography. The aim of this study was to analyze the changes in myocardial strain and strain rate patterns in patients with end-stage renal disease and renal transplant recipients. We studied 33 patients with end-stage renal disease on hemodialysis (19 men; mean age, 36 ± 8 y), 24 renal transplant recipients with functional grafts (21 men; mean age, 36 ± 7 y) and 26 age- and sex-matched control subjects. Longitudinal peak systolic strain and strain rate for basal, mid, and apical segments of the left ventricular wall were determined by velocity vector imaging from apical 4- and 2-chamber views. The average longitudinal strain and strain rate for the left ventricle were noted. From short-axis views at the level of papillary muscles, average circumferential, and radial strain, and strain rate were assessed. Mean heart rate and systolic and diastolic blood pressure during imaging were similar between the groups. Longitudinal peak systolic strain and strain rate at basal and mid-segments of the lateral wall were significantly higher in renal transplant recipients and control groups than endstage renal disease patients. Average longitudinal systolic strain from the 4-chamber view was highest in control subjects (-14.5% ± 2.9%) and was higher in renal transplant recipients (-12.5% ± 3.0%) than end-stage renal disease patients (-10.2% ± 1.6%; P ≤ .001). Radial and circumferential strain and strain rate at the level of the papillary muscle were lower in patients with end-stage renal disease than other groups. Differences in myocardial function in patients with end-stage renal disease, renal transplant recipients, and normal controls can be quantified by strain imaging. Myocardial function is improved in renal transplant recipients compared with end-stage renal disease patients.
Cho, Eun Jeong; Park, Sung-Ji; Kim, Eun Kyoung; Lee, Ga Yeon; Chang, Sung-A; Choi, Jin-Oh; Lee, Sang-Chol; Park, Seung Woo
2017-04-01
The aim of this study was to determine the capability of real time three-dimensional echocardiography (RT3DE) and two-dimensional (2D) multilayer speckle tracking echocardiography (MSTE) for evaluation of early myocardial dysfunction triggered by increased left ventricular (LV) wall thickness in severe aortic stenosis (AS) with normal LV ejection fraction (EF≥55%). Conventional, RT3D STE and 2D MSTE were performed in 45 patients (mean 68.9±9.0 years) with severe AS (aortic valve area <1 cm 2 , aortic velocity Vmax >4 m/s or mean PG >40 mm Hg) and normal left ventricular ejection fraction (LVEF) without overt coronary artery disease and in 18 age-, sex-matched healthy controls. Global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS), and global radial strain (GRS) were calculated using RT3DE and MSTE. The severe AS group had lower 3D GLS, GRS, GAS and 2D epicardium, and mid-wall and endocardium GLS compared to healthy controls. In MSTE analysis, 2D LS and CS values decreased from the endocardial layer toward the epicardial layer. Severe AS patients with increased LV wall thickness had lower 3D GLS and 2D epicardium, and mid-wall and endocardium GLS compared with severe AS patients without LV wall thickening. GLS on RT3D STE was correlated with GLS on 2D MSTE, left ventricular mass index, LVEF, left atrial volume index, and lnNT-proBNP. RT3DE and 2D MSTE can be used to identify subtle contractile dysfunction triggered by increased LV wall thickness in severe AS with normal LVEF. Therefore, RT3D STE and 2D MSTE may provide additional information that can facilitate decision-making regarding severe AS patients with increased LV wall thickness and normal LV function. © 2017, Wiley Periodicals, Inc.
Moser, Julia; Sultan, Arian; Lüker, Jakob; Servatius, Helge; Salzbrunn, Tim; Altenburg, Manuel; Schäffer, Benjamin; Schreiber, Doreen; Akbulak, Ruken Ö; Vogler, Julia; Hoffmann, Boris A; Willems, Stephan; Steven, Daniel
2017-11-01
This study sought to compare long-term arrhythmia-free survival between electrical circumferential pulmonary vein isolation (PVI) and PVI with the endpoint of unexcitability along the ablation line. PVI is the standard ablation strategy of paroxysmal atrial fibrillation, although arrhythmia recurrence in long-term follow-up (FU) is high. The endpoint of unexcitability along the ablation line results in decreased arrhythmia recurrence compared to electrical PVI in 1-year FU. Seventy-four consecutive patients (age 62.5 ± 10.6 years; 70.3% male) with de novo paroxysmal atrial fibrillation who were initially included in our randomized trial and underwent catheter ablation at our institution were analyzed. Patients who were randomized to either a conventional group (PVI, guided by circumferential catheter signals) or a pace-guided group (PG, anatomical ablation line encircling, ablation until loss of pace capture at 10 V, 2-ms pulse width on the ablation line) underwent long-term FU. The primary endpoint was recurrence of any atrial fibrillation or atrial tachycardia after a blanking period of 3 months. Sixty-nine patients completed a mean FU period of 5.14 ± 0.98 years. Arrhythmia-free survival without antiarrhythmic drug therapy was significantly higher in the PG group (71.05% vs. 25.81%, p = 0.002). Furthermore, multiple procedure success (1.29 ± 0.61 procedures in PG vs. 1.97 ± 1.06 procedures in conventional group, p < 0.001) was higher in the PG group compared to the conventional group (89.47% vs. 58.06%, p = 0.005). The endpoint of unexcitability along the PVI line improves success rates, resulting in a significant reduction of exposure to invasive procedures in 5-year FU. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
A Geodetic Strain Rate Model for the East African Rift System.
Stamps, D S; Saria, E; Kreemer, C
2018-01-15
Here we describe the new Sub-Saharan Africa Geodetic Strain Rate Model v.1.0 (SSA-GSRM v.1.0), which provides fundamental constraints on long-term tectonic deformation in the region and an improved seismic hazards assessment in Sub-Saharan Africa. Sub-Saharan Africa encompasses the East African Rift System, the active divergent plate boundary between the Nubian and Somalian plates, where strain is largely accommodated along the boundaries of three subplates. We develop an improved geodetic strain rate field for sub-Saharan Africa that incorporates 1) an expanded geodetic velocity field, 2) redefined regions of deforming zones guided by seismicity distribution, and 3) updated constraints on block rotations. SSA-GSRM v.1.0 spans longitudes 22° to 55.5° and latitudes -52° to 20° with 0.25° (longitude) by 0.2° (latitude) spacing. For plates/sub-plates, we assign rigid block rotations as constraints on the strain rate calculation that is determined by fitting bicubic Bessel splines to a new geodetic velocity solution for an interpolated velocity gradient tensor field. We derive strain rates, velocities, and vorticity rates from the velocity gradient tensor field. A comparison with the Global Geodetic Strain Rate model v2.1 reveals regions of previously unresolved spatial heterogeneities in geodetic strain rate distribution, which indicates zones of elevated seismic risk.
Fonseca, Carissa G; Oxenham, Helen C; Cowan, Brett R; Occleshaw, Christopher J; Young, Alistair A
2003-08-01
Although age-related impairment of diastolic function is well documented, patterns of regional tissue relaxation impairment with age have not been characterized. MRI tissue tagging with a regional three-dimensional (3-D) analysis was performed in 15 younger (age 19-26 yr) and 16 older (age 60-74 yr) normal, healthy volunteers. The peak rate of relaxation of circumferential strain (RC) was decreased in the older group (on average, 105 +/- 28 vs. 163 +/- 18 %/s for older vs. younger, mean +/- SD, P < 0.001) to a greater extent in the lateral wall than in the septum (P = 0.016) and to a greater extent in the apex than in the base (P < 0.001). Peak rate of relaxation of longitudinal strain (RL) was also reduced with age (94 +/- 27 vs. 155 +/- 18 %/s, P < 0.001) to a greater extent in the apex than in the base (P < 0.001). Both RC and RL were greater in the apex than in the base only in the younger subjects (P < 0.001 for each). Peak rate of torsion reversal (RT) was reduced with age (74 +/- 16 vs. 91 +/- 15 degrees/s, P = 0.006) to a greater extent in the base than in the apex (P = 0.035). An increase in regional asynchrony in time to RC and time to RL (P < 0.001 for each), but not time to RT, occurred with age. Thus patterns of regional nonuniformity of myocardial relaxation are altered in a consistent fashion with aging.
Response of turbulence subjected to a straining-relaxation-destraining cycle
NASA Astrophysics Data System (ADS)
Chen, Jun; Meneveau, Charles; Katz, Joseph
2004-11-01
The response of turbulence subjected to planar straining and de-straining is studied experimentally, and the impact of the applied distortions on the energy transfer across different length scales is quantified. The data are obtained using Planar Particle Image Velocimetry (PIV) in a water tank, in which high Reynolds number turbulence with very low mean velocity is generated by an array of spinning grids. Planar straining and de-straining mean flows are produced by pushing and pulling a rectangular piston towards, and away from, the bottom wall of the tank. The data are processed to yield the time evolution of Reynolds stresses, anisotropy tensors, turbulence kinetic energy production, and mean subgrid dissipation rate at various scales. During straining, the production rises rapidly. After the relaxation period the small-scale SGS stresses recover isotropy, but the Reynolds stresses at large scales still display significant anisotropy. When destraining is applied, a strong negative production (back-scattering) is observed, by which turbulence fluctuations return kinetic energy to the mean flow. Reversed energy transfer is also revealed in the vorticity fluctuations history. The experiment allows to disentangle in detail the causes for this global backscatter phenomenon in terms of non-equilibrium conditions of the Reynolds stresses, and to follow the trends as function of scale.
Kleinhans, Kelsey L; Jaworski, Lukas M; Schneiderbauer, Michaela M; Jackson, Alicia R
2015-10-01
Osteoarthritis (OA) is a significant socio-economic concern, affecting millions of individuals each year. Degeneration of the meniscus of the knee is often associated with OA, yet the relationship between the two is not well understood. As a nearly avascular tissue, the meniscus must rely on diffusive transport for nutritional supply to cells. Therefore, quantifying structure-function relations for transport properties in meniscus fibrocartilage is an important task. The purpose of the present study was to determine how mechanical loading, tissue anisotropy, and tissue region affect glucose diffusion in meniscus fibrocartilage. A one-dimensional (1D) diffusion experiment was used to measure the diffusion coefficient of glucose in porcine meniscus tissues. Results show that glucose diffusion is strain-dependent, decreasing significantly with increased levels of compression. It was also determined that glucose diffusion in meniscus tissues is anisotropic, with the diffusion coefficient in the circumferential direction being significantly higher than that in the axial direction. Finally, the effect of tissue region was not statistically significant, comparing axial diffusion in the central and horn regions of the tissue. This study is important for better understanding the transport and nutrition-related mechanisms of meniscal degeneration and related OA in the knee.
Haggerty, Christopher M; Kramer, Sage P; Binkley, Cassi M; Powell, David K; Mattingly, Andrea C; Charnigo, Richard; Epstein, Frederick H; Fornwalt, Brandon K
2013-08-27
Advanced measures of cardiac function are increasingly important to clinical assessment due to their superior diagnostic and predictive capabilities. Cine DENSE cardiovascular magnetic resonance (CMR) is ideal for quantifying advanced measures of cardiac function based on its high spatial resolution and streamlined post-processing. While many studies have utilized cine DENSE in both humans and small-animal models, the inter-test and inter-observer reproducibility for quantification of advanced cardiac function in mice has not been evaluated. This represents a critical knowledge gap for both understanding the capabilities of this technique and for the design of future experiments. We hypothesized that cine DENSE CMR would show excellent inter-test and inter-observer reproducibility for advanced measures of left ventricular (LV) function in mice. Five normal mice (C57BL/6) and four mice with depressed cardiac function (diet-induced obesity) were imaged twice, two days apart, on a 7T ClinScan MR system. Images were acquired with 15-20 frames per cardiac cycle in three short-axis (basal, mid, apical) and two long-axis orientations (4-chamber and 2-chamber). LV strain, twist, torsion, and measures of synchrony were quantified. Images from both days were analyzed by one observer to quantify inter-test reproducibility, while inter-observer reproducibility was assessed by a second observer's analysis of day-1 images. The coefficient of variation (CoV) was used to quantify reproducibility. LV strains and torsion were highly reproducible on both inter-observer and inter-test bases with CoVs ≤ 15%, and inter-observer reproducibility was generally better than inter-test reproducibility. However, end-systolic twist angles showed much higher variance, likely due to the sensitivity of slice location within the sharp longitudinal gradient in twist angle. Measures of synchrony including the circumferential (CURE) and radial (RURE) uniformity of strain indices, showed excellent
Suppression of Low Strain Rate Nonpremixed Flames by an Agent
NASA Technical Reports Server (NTRS)
Olson, Sandra L. (Technical Monitor); Hamins, A.; Bundy, M.; Oh, C. B.; Park, J.; Puri, I. K.
2004-01-01
The extinction and structure of non-premixed methane/air flames were investigated in normal gravity and microgravity through the comparison of experiments and calculations using a counterflow configuration. From a fire safety perspective, low strain rate conditions are important for several reasons. In normal gravity, many fires start from small ignition sources where the convective flow and strain rates are weak. Fires in microgravity conditions, such as a manned spacecraft, may also occur in near quiescent conditions where strain rates are very low. When designing a fire suppression system, worst-case conditions should be considered. Most diffusion flames become more robust as the strain rate is decreased. The goal of this project is to investigate the extinction limits of non-premixed flames using various agents and to compare reduced gravity and normal gravity conditions. Experiments at the NASA Glenn Research Center's 2.2-second drop tower were conducted to attain extinction and temperature measurements in low-strain non-premixed flames. Extinction measurements using nitrogen added to the fuel stream were performed for global strain rates from 7/s to 50/s. The results confirmed the "turning point" behavior observed previously by Maruta et al. in a 10 s drop tower. The maximum nitrogen volume fraction in the fuel stream needed to assure extinction for all strain rates was measured to be 0.855+/-0.016, associated with the turning point determined to occur at a strain rate of 15/s. The critical nitrogen volume fraction in the fuel stream needed for extinction of 0-g flames was measured to be higher than that of 1-g flames.
Spalla, I; Locatelli, C; Zanaboni, A M; Brambilla, P; Bussadori, C
2016-05-01
Patent ductus arteriosus (PDA) is 1 of the most common congenital heart defects in dogs and percutaneous closure is effective in achieving ductal closure; PDA closure is associated with abrupt hemodynamic changes. A marked decrease in standard parameters of systolic function as assessed by M- or B-mode echocardiography after PDA closure was identified in previous studies. Speckle tracking echocardiography can provide further insight into the effect of PDA closure on cardiac mechanics in dogs affected by PDA. Twenty-five client-owned dogs with PDA. Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed before and 24 hours after PDA closure, including standard (end-diastolic volumes indexed to body surface area in B- and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B- and M-mode [ESVIB /M ], allometric scaling in diastole [AlloD] and systole [AlloS], pulmonary flow to systemic flow [Qs/Qp], ejection fraction [EF], and fractional shortening [FS]), and advanced speckle-tracking echocardiography (STE): global longitudinal, radial, circumferential and transverse strain (S), and strain rate (SR). Patent ductus arteriosus closure was associated with statistically significant decreases in EDVIM /B and ESVIM /B , AlloD and AlloS, SI, EF, and FS. A statistically significant decrease in the absolute values of radial, transverse, and circumferential S and SR was observed, whereas longitudinal S and SR did not change significantly. Patent ductus arteriosus closure by percutaneous approach is associated with marked decreases of conventional echocardiographic parameters as a result of the changes in loading conditions, but no evidence of systolic dysfunction was identified by means of STE, as none of the S and SR values were below reference ranges. In the short term, contractility is enhanced in the long axis (long S/SR values were not statistically different before and after closure) and
Strain Control of Exciton-Phonon Coupling in Atomically Thin Semiconductors.
Niehues, Iris; Schmidt, Robert; Drüppel, Matthias; Marauhn, Philipp; Christiansen, Dominik; Selig, Malte; Berghäuser, Gunnar; Wigger, Daniel; Schneider, Robert; Braasch, Lisa; Koch, Rouven; Castellanos-Gomez, Andres; Kuhn, Tilmann; Knorr, Andreas; Malic, Ermin; Rohlfing, Michael; Michaelis de Vasconcellos, Steffen; Bratschitsch, Rudolf
2018-03-14
Semiconducting transition metal dichalcogenide (TMDC) monolayers have exceptional physical properties. They show bright photoluminescence due to their unique band structure and absorb more than 10% of the light at their excitonic resonances despite their atomic thickness. At room temperature, the width of the exciton transitions is governed by the exciton-phonon interaction leading to strongly asymmetric line shapes. TMDC monolayers are also extremely flexible, sustaining mechanical strain of about 10% without breaking. The excitonic properties strongly depend on strain. For example, exciton energies of TMDC monolayers significantly redshift under uniaxial tensile strain. Here, we demonstrate that the width and the asymmetric line shape of excitonic resonances in TMDC monolayers can be controlled with applied strain. We measure photoluminescence and absorption spectra of the A exciton in monolayer MoSe 2 , WSe 2 , WS 2 , and MoS 2 under uniaxial tensile strain. We find that the A exciton substantially narrows and becomes more symmetric for the selenium-based monolayer materials, while no change is observed for atomically thin WS 2 . For MoS 2 monolayers, the line width increases. These effects are due to a modified exciton-phonon coupling at increasing strain levels because of changes in the electronic band structure of the respective monolayer materials. This interpretation based on steady-state experiments is corroborated by time-resolved photoluminescence measurements. Our results demonstrate that moderate strain values on the order of only 1% are already sufficient to globally tune the exciton-phonon interaction in TMDC monolayers and hold the promise for controlling the coupling on the nanoscale.
Lech, Agnieszka K; Dobrowolski, Piotr P; Klisiewicz, Anna; Hoffman, Piotr
2017-01-01
The management of patients with asymptomatic severe aortic stenosis (ASAS) is still under discussion. Therefore, it is advisable to search for the parameters of early damage to left ventricular (LV) function. The aim of the study was to assess exercise-induced changes in LV global longitudinal strain (GLS) in ASAS. The ASAS group consisted of 50 patients (26 women and 24 men, aged 38.4 ± 18.1 years) meeting the echocardiographic criteria of severe aortic stenosis (AVA < 1 cm², AVAI < 0.6 cm²/m², Vmax > 4 m/s, mean aortic gradient > 40 mm Hg), with normal LV ejection fraction (LVEF ≥ 55%) and sinus rhythm on electrocardiogram, and without significant concomitant valvular heart diseases. The control group consisted of 21 people matched for age and sex. Echocardiographic examinations and echocardiographic stress tests with the assessment of GLS using the speckle tracking imaging were performed. The ASAS group was characterised by statistically significantly higher LV mass index (LVMI) and higher LVEF. GLS values at rest in both groups were within normal limits but were significantly higher in the control group (-18.9 ± 2.4% vs. -20.7 ± 1.7%, p = 0.006). An increase in GLS at peak exercise in both groups was observed, lower in the ASAS group (the difference was not statistically significant: -0.8 ± 3.0% vs. -2.2 ± 3.1%, p = 0.086). Changes in GLS during exercise (ΔGLS) did not correlate with the parameters of the severity of aortic stenosis. In the multivariate model, LVMI proved to be a factor associated with GLS at rest and during exercise. In patients with ASAS, GLS is a non-invasive marker of an early stage of LV myocardial damage associated with myocardial hypertrophy. An increase in GLS during exercise in the ASAS group, smaller than in the control group, indicates a preserved functional reserve of the LV myocardium but smaller than in healthy individuals. The assessment of the clinical usefulness of exercise-induced changes in GLS requires further
Bowen, Christopher D.; Renner, Daniel W.; Shreve, Jacob T.; Tafuri, Yolanda; Payne, Kimberly M.; Dix, Richard D.; Kinchington, Paul R.; Gatherer, Derek; Szpara, Moriah L.
2016-01-01
Herpes simplex virus 1 (HSV-1) is a widespread global pathogen, of which the strain KOS is one of the most extensively studied. Previous sequence studies revealed that KOS does not cluster with other strains of North American geographic origin, but instead clustered with Asian strains. We sequenced a historical isolate of the original KOS strain, called KOS63, along with a separately isolated strain attributed to the same source individual, termed KOS79. Genomic analyses revealed that KOS63 closely resembled other recently sequenced isolates of KOS and was of Asian origin, but that KOS79 was a genetically unrelated strain that clustered in genetic distance analyses with HSV-1 strains of North American/European origin. These data suggest that the human source of KOS63 and KOS79 could have been infected with two genetically unrelated strains of disparate geographic origins. A PCR RFLP test was developed for rapid identification of these strains. PMID:26950505
Bowen, Christopher D; Renner, Daniel W; Shreve, Jacob T; Tafuri, Yolanda; Payne, Kimberly M; Dix, Richard D; Kinchington, Paul R; Gatherer, Derek; Szpara, Moriah L
2016-05-01
Herpes simplex virus 1 (HSV-1) is a widespread global pathogen, of which the strain KOS is one of the most extensively studied. Previous sequence studies revealed that KOS does not cluster with other strains of North American geographic origin, but instead clustered with Asian strains. We sequenced a historical isolate of the original KOS strain, called KOS63, along with a separately isolated strain attributed to the same source individual, termed KOS79. Genomic analyses revealed that KOS63 closely resembled other recently sequenced isolates of KOS and was of Asian origin, but that KOS79 was a genetically unrelated strain that clustered in genetic distance analyses with HSV-1 strains of North American/European origin. These data suggest that the human source of KOS63 and KOS79 could have been infected with two genetically unrelated strains of disparate geographic origins. A PCR RFLP test was developed for rapid identification of these strains. Copyright © 2016 Elsevier Inc. All rights reserved.
Hu, Wei; Zhao, Qing-yan; Yu, Sheng-bo; Sun, Bin; Chen, Liao; Cao, Sheng; Guo, Rui-qiang
2014-11-22
The purpose of this study was to investigate whether transcatheter renal sympathetic denervation (RSD) interfere with the development of left ventricular (LV) mechanical dyssynchrony during the progression of heart failure (HF). Nineteen beagles were randomly divided into sham-operated group (six dogs), control group (seven dogs), and RSD group (six dogs). Sham-operated group were implanted with pacemakers without pacing; Control group were implanted with pacemakers and underwent 3 weeks of rapid right ventricular pacing; and RSD group underwent catheter-based RSD bilaterally and were simultaneously implanted with pacemakers. Both LV strain and LV dyssynchrony were analyzed via 2D speckle-tracking strain echocardiography to evaluate LV function. Longitudinal dyssynchrony was determined as the standard deviation for time-to-peak speckle-tracking strain on apical 4- and 2-chamber views. Radial and circumferential dyssynchrony was determined as the standard deviation for time-to-peak speckle-tracking strain in mid- and base-LV short-axis views. Each myocardial function was also evaluated by averaging the peak systolic strains. LV systolic pressure (LVSP) and LV end-diastolic pressure (LVEDP) were measured. The LV interstitial fibrosis was determined by histological analysis. Plasma angiotensin II (Ang II), aldosterone and norepinephrine (NE) levels were also measured. After 3 weeks, all of the dogs in both the control and RSD groups showed greater LV end-diastolic volume compared with the sham-operated group; however, the dogs in the RSD group had a higher LV ejection fraction (LVEF) than the dogs in the control group (p<0.001). The LV systolic strains were higher in the RSD group than in the control group (p<0.001 for longitudinal, circumferential and radial strain, respectively). The levels of LV dyssynchrony were lower in the RSD group than in the control group (p<0.001 for longitudinal, circumferential and radial dyssynchrony, respectively). Compared with dogs
Characterization of clinical Vibrio parahaemolyticus strains in Zhoushan, China, from 2013 to 2014.
Wang, Hongling; Tang, Xiaoyang; Su, Yi-Cheng; Chen, Jiabei; Yan, Jianbo
2017-01-01
Vibrio parahaemolyticus is recognized as major cause of foodborne illness of global public health concern. This study collected 107 strains of V. parahaemolyticus during active surveillance of diarrheal diseases in hospitals in Zhoushan during 2013 to 2014 and investigated their serotypes, virulence genes (tdh, trh, and orf8), antimicrobial resistance, and genotypes. The dominant serotypes of the 107 clinical strains were O3:K6, O4:K8, and O4:KUT with 87.9% and 3.7% of the strains carrying the virulence genes tdh and trh, respectively. Molecular typing by pulsed-field gel electrophoresis indicated divergence among the clinical strains. Most isolates were sensitive to the common antimicrobial agents used against the Vibrio species except ampicillin. We conclude that continuous surveillance of V. parahaemolyticus in diarrhea patients is a public health priority and is useful for conducting risk assessment of foodborne illnesses caused by V. parahaemolyticus.
Left ventricular longitudinal strain in soccer referees.
Gianturco, Luigi; Bodini, Bruno; Gianturco, Vincenzo; Lippo, Giuseppina; Solbiati, Agnese; Turiel, Maurizio
2017-06-13
Along the years, the analysis of soccer referees perfomance has interested the experts and we can find several types of studies in literature using in particular cardiac imaging. The aim of this retrospective study was to observe relationship between VO2max uptake and some conventional and not-conventional echocardiographic parameters. In order to perform this evaluation, we have enrolled 20 referees, belonging to Italian Soccer Referees' Association and we have investigated cardiovascular profile of them. We found a strong direct relationship between VO2max and global longitudinal strain of left ventricle assessed by means of speckle tracking echocardiographic analysis (R2=0.8464). The most common classic echocardiographic indexes have showed mild relations (respectively, VO2max vs EF: R2=0.4444; VO2max vs LV indexed mass: R2=0.2268). Therefore, our study suggests that longitudinal strain could be proposed as a specific echocardiographic parameter to evaluate the soccer referees performance.
Olaya-Abril, Alfonso; Luque-Almagro, Víctor M; Manso, Isabel; Gates, Andrew J; Moreno-Vivián, Conrado; Richardson, David J
2017-01-01
Abstract Paracoccus denitrificans PD1222 accumulates short-length polyhydroxyalkanoates, poly(3-hydroxybutyrate), under nitrogen-deficient conditions. Polyhydroxybutyrate metabolism requires the 3-ketoacyl-CoA thiolase PhaA, the acetoacetyl-CoA dehydrogenase/reductase PhaB and the synthase PhaC for polymerization. Additionally, P. denitrificans PD1222 grows aerobically with nitrate as sole nitrogen source. Nitrate assimilation is controlled negatively by ammonium through the two-component NtrBC system. NtrB is a sensor kinase that autophosphorylates a histidine residue under low-nitrogen concentrations and, in turn, transfers a phosphoryl group to an aspartate residue of the response regulator NtrC protein, which acts as a transcriptional activator of the P. denitrificans PD1222 nasABGHC genes. The P. denitrificans PD1222 NtrB mutant was unable to use nitrate efficiently as nitrogen source when compared to the wild-type strain, and it also overproduced poly(3-hydroxybutyrate). Acetyl-CoA concentration in the P. denitrificans PD1222 NtrB mutant strain was higher than in the wild-type strain. The expression of the phaC gene was also increased in the NtrB mutant when compared to the wild-type strain. These results suggest that accumulation of poly(3-hydroxybutyrate) in the NtrB mutant strain of PD1222 responds to the high levels of acetyl-CoA that accumulate in the cytoplasm as consequence of its inability to efficiently use nitrate as nitrogen source. PMID:29228177
Global isotope metabolomics reveals adaptive strategies for nitrogen assimilation
Kurczy, Michael E.; Forsberg, Erica M.; Thorgersen, Michael P.; ...
2016-04-05
Nitrogen cycling is a microbial metabolic process essential for global ecological/agricultural balance. To investigate the link between the well-established ammonium and the alternative nitrate assimilation metabolic pathways, global isotope metabolomics was employed to examine three nitrate reducing bacteria using 15NO 3 as a nitrogen source. In contrast to a control ( Pseudomonas stutzeri RCH2), the results show that two of the isolates from Oak Ridge, Tennessee ( Pseudomonas N2A2 and N2E2) utilize nitrate and ammonia for assimilation concurrently with differential labeling observed across multiple classes of metabolites including amino acids and nucleotides. The data reveal that the N2A2 and N2E2more » strains conserve nitrogen-containing metabolites, indicating that the nitrate assimilation pathway is a conservation mechanism for the assimilation of nitrogen. Co-utilization of nitrate and ammonia is likely an adaption to manage higher levels of nitrite since the denitrification pathways utilized by the N2A2 and N2E2 strains from the Oak Ridge site are predisposed to the accumulation of the toxic nitrite. In conclusion, the use of global isotope metabolomics allowed for this adaptive strategy to be investigated, which would otherwise not have been possible to decipher.« less
Global isotope metabolomics reveals adaptive strategies for nitrogen assimilation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurczy, Michael E.; Forsberg, Erica M.; Thorgersen, Michael P.
Nitrogen cycling is a microbial metabolic process essential for global ecological/agricultural balance. To investigate the link between the well-established ammonium and the alternative nitrate assimilation metabolic pathways, global isotope metabolomics was employed to examine three nitrate reducing bacteria using 15NO 3 as a nitrogen source. In contrast to a control ( Pseudomonas stutzeri RCH2), the results show that two of the isolates from Oak Ridge, Tennessee ( Pseudomonas N2A2 and N2E2) utilize nitrate and ammonia for assimilation concurrently with differential labeling observed across multiple classes of metabolites including amino acids and nucleotides. The data reveal that the N2A2 and N2E2more » strains conserve nitrogen-containing metabolites, indicating that the nitrate assimilation pathway is a conservation mechanism for the assimilation of nitrogen. Co-utilization of nitrate and ammonia is likely an adaption to manage higher levels of nitrite since the denitrification pathways utilized by the N2A2 and N2E2 strains from the Oak Ridge site are predisposed to the accumulation of the toxic nitrite. In conclusion, the use of global isotope metabolomics allowed for this adaptive strategy to be investigated, which would otherwise not have been possible to decipher.« less
Mechanical characterization of stomach tissue under uniaxial tensile action.
Jia, Z G; Li, W; Zhou, Z R
2015-02-26
In this article, the tensile properties of gastric wall were investigated by using biomechanical test and theoretical analysis. The samples of porcine stomach strips from smaller and greater curvature of the stomach were cut in longitudinal and circumferential direction, respectively. The loading-unloading, stress relaxation, strain creep, tensile fracture tests were performed at mucosa-submucosa, serosa-muscle and intact layer, respectively. Results showed that the biomechanical properties of the porcine stomach depended on the layers, orientations and locations of the gastric wall and presented typical viscoelastic, nonlinear and anisotropic mechanical properties. During loading-unloading test, the stress of serosa-muscle layer in the longitudinal direction was 15-20% more than that in the circumferential direction at 12% stretch ratio, while it could reach about 40% for the intact layer and 50% for the mucosa-submucosa layer. The results of stress relaxation and strain creep showed that the variation degree was obviously faster in the circumferential direction than that in the longitudinal direction, and the ultimate residual values were also different for the different layers, orientations and locations. In the process of fracture test, the serosa-muscle layer fractured firstly followed by the mucosa-submucosa layer when the intact layer was tested, the longitudinal strips firstly began to fracture and the required stress value was about twice as much as that in the circumferential strips. The anisotropy and heterogeneity of mechanical characterization of the porcine stomach were related to its complicated geometry, structure and functions. The results would help us to understand the biomechanics of soft organ tissue. Copyright © 2015 Elsevier Ltd. All rights reserved.
Choi, Eunsoo; Kim, Dongkyun; Park, Kyoungsoo
2014-12-01
For external jackets of reinforced concrete columns, shape memory alloy (SMA) wires are easy to install, and they provide active and passive confining pressure; steel plates, on the other hand, only provide passive confining pressure, and their installation on concrete is not convenient because of the requirement of a special device. To investigate how SMA wires distinctly impact bond behavior compared with steel plates, this study conducted push-out bond tests of steel reinforcing bars embedded in concrete confined by SMA wires or steel plates. For this purpose, concrete cylinders were prepared with dimensions of 100 mm x 200 mm, and D-22 reinforcing bars were embedded at the center of the concrete cylinders. External jackets of 1.0 mm and 1.5 mm thickness steel plates were used to wrap the concrete cylinders. Additionally, NiTiNb SMA wire with a diameter of 1.0 mm was wound around the concrete cylinders. Slip of the reinforcing bars due to pushing force was measured by using a displacement transducer, while the circumferential deformation of specimens was obtained by using an extensometer. The circumferential deformation was used to calculate the circumferential strains of the specimens. This study assessed the radial confining pressure due to the external jackets on the reinforcing bars at bond strength from bond stress-slip curves and bond stress-circumferential strain curves. Then, the effects of the radial confining pressure on the bond behavior of concrete are investigated, and an equation is suggested to estimate bond strength using the radial confining pressure. Finally, this study focused on how active confining pressure due to recovery stress of the SMA wires influences bond behavior.
An integrated approach to model strain localization bands in magnesium alloys
NASA Astrophysics Data System (ADS)
Baxevanakis, K. P.; Mo, C.; Cabal, M.; Kontsos, A.
2018-02-01
Strain localization bands (SLBs) that appear at early stages of deformation of magnesium alloys have been recently associated with heterogeneous activation of deformation twinning. Experimental evidence has demonstrated that such "Lüders-type" band formations dominate the overall mechanical behavior of these alloys resulting in sigmoidal type stress-strain curves with a distinct plateau followed by pronounced anisotropic hardening. To evaluate the role of SLB formation on the local and global mechanical behavior of magnesium alloys, an integrated experimental/computational approach is presented. The computational part is developed based on custom subroutines implemented in a finite element method that combine a plasticity model with a stiffness degradation approach. Specific inputs from the characterization and testing measurements to the computational approach are discussed while the numerical results are validated against such available experimental information, confirming the existence of load drops and the intensification of strain accumulation at the time of SLB initiation.
Development and introduction of inactivated poliovirus vaccines derived from Sabin strains in Japan.
Shimizu, Hiroyuki
2016-04-07
During the endgame of global polio eradication, the universal introduction of inactivated poliovirus vaccines is urgently required to reduce the risk of vaccine-associated paralytic poliomyelitis and polio outbreaks due to wild and vaccine-derived polioviruses. In particular, the development of inactivated poliovirus vaccines (IPVs) derived from the attenuated Sabin strains is considered to be a highly favorable option for the production of novel IPV that reduce the risk of facility-acquired transmission of poliovirus to the communities. In Japan, Sabin-derived IPVs (sIPVs) have been developed and introduced for routine immunization in November 2012. They are the first licensed sIPVs in the world. Consequently, trivalent oral poliovirus vaccine was used for polio control in Japan for more than half a century but has now been removed from the list of vaccines licensed for routine immunization. This paper reviews the development, introduction, characterization, and global status of IPV derived from attenuated Sabin strains. Copyright © 2014 Elsevier Ltd. All rights reserved.
Reconstruction of loads in the fibrosa and ventricularis of porcine aortic valves.
Vesely, I
1996-01-01
The main structural components of aortic valve cusps, the fibrosa and ventricularis, are pre loaded by virtue of their attachment to each other. The fibrosa is under compression and the ventricularis is under tension. Once separated from each other, these internal stresses are relieved, and the fibrosa elongates and the ventricularis shrinks. It then becomes impossible to determine what fraction of the load is carried by the two layers at a given strain, using the standard superposition of tension vs strain curves. To enable the superposition approach, we needed to adjust the tension/ strain curves of the fibrosa and ventricularis, and duplicate the pre load that exists in these layers. We, therefore, iteratively shifted these curves and compared their arithmetic sum to the tension curve for the whole intact cusp, using a sum-of-squares error function. The best fits occurred when the fibrosa and ventricularis were shifted to the right and left by amounts corresponding to a true strain of epsilon = 0.26 and 0.10 for the fibrosa and ventricularis in the radial directions. In the circumferential direction, the best fit was achieved for shifts of epsilon = -0.11 and 0.010 for the fibrosa and ventricularis, respectively. This 26% compressive strain of the radial fibrosa compares well with direct observations. The reconstructed tension curves indicate that the ventricularis carries much of the radial loads, whereas circumferentially the two layers share loads equally up to 25% strain, beyond which the fibrosa takes over.
Hartlage, Gregory R; Kim, Jonathan H; Strickland, Patrick T; Cheng, Alan C; Ghasemzadeh, Nima; Pernetz, Maria A; Clements, Stephen D; Williams, B Robinson
2015-03-01
Speckle-tracking left ventricular global longitudinal strain (GLS) assessment may provide substantial prognostic information for hypertrophic cardiomyopathy (HCM) patients. Reference values for GLS have been recently published. We aimed to evaluate the prognostic value of standardized reference values for GLS in HCM patients. An analysis of HCM clinic patients who underwent GLS was performed. GLS was defined as normal (more negative or equal to -16%) and abnormal (less negative than -16%) based on recently published reference values. Patients were followed for a composite of events including heart failure hospitalization, sustained ventricular arrhythmia, and all-cause death. The power of GLS to predict outcomes was assessed relative to traditional clinical and echocardiographic variables present in HCM. 79 HCM patients were followed for a median of 22 months (interquartile range 9-30 months) after imaging. During follow-up, 15 patients (19%) met the primary outcome. Abnormal GLS was the only echocardiographic variable independently predictive of the primary outcome [multivariate Hazard ratio 5.05 (95% confidence interval 1.09-23.4, p = 0.038)]. When combined with traditional clinical variables, abnormal GLS remained independently predictive of the primary outcome [multivariate Hazard ratio 5.31 (95 % confidence interval 1.18-24, p = 0.030)]. In a model including the strongest clinical and echocardiographic predictors of the primary outcome, abnormal GLS demonstrated significant incremental benefit for risk stratification [net reclassification improvement 0.75 (95 % confidence interval 0.21-1.23, p < 0.0001)]. Abnormal GLS is an independent predictor of adverse outcomes in HCM patients. Standardized use of GLS may provide significant incremental value over traditional variables for risk stratification.
Kumar, Vinod; Sun, Peng; Vamathevan, Jessica; Li, Yong; Ingraham, Karen; Palmer, Leslie; Huang, Jianzhong; Brown, James R.
2011-01-01
There is a global emergence of multidrug-resistant (MDR) strains of Klebsiella pneumoniae, a Gram-negative enteric bacterium that causes nosocomial and urinary tract infections. While the epidemiology of K. pneumoniae strains and occurrences of specific antibiotic resistance genes, such as plasmid-borne extended-spectrum β-lactamases (ESBLs), have been extensively studied, only four complete genomes of K. pneumoniae are available. To better understand the multidrug resistance factors in K. pneumoniae, we determined by pyrosequencing the nearly complete genome DNA sequences of two strains with disparate antibiotic resistance profiles, broadly drug-susceptible strain JH1 and strain 1162281, which is resistant to multiple clinically used antibiotics, including extended-spectrum β-lactams, fluoroquinolones, aminoglycosides, trimethoprim, and sulfamethoxazoles. Comparative genomic analysis of JH1, 1162281, and other published K. pneumoniae genomes revealed a core set of 3,631 conserved orthologous proteins, which were used for reconstruction of whole-genome phylogenetic trees. The close evolutionary relationship between JH1 and 1162281 relative to other K. pneumoniae strains suggests that a large component of the genetic and phenotypic diversity of clinical isolates is due to horizontal gene transfer. Using curated lists of over 400 antibiotic resistance genes, we identified all of the elements that differentiated the antibiotic profile of MDR strain 1162281 from that of susceptible strain JH1, such as the presence of additional efflux pumps, ESBLs, and multiple mechanisms of fluoroquinolone resistance. Our study adds new and significant DNA sequence data on K. pneumoniae strains and demonstrates the value of whole-genome sequencing in characterizing multidrug resistance in clinical isolates. PMID:21746949
Bérard, Jean-Baptiste; Kaas, Raymond; Pasquet, Virginie; Picot, Laurent; Cadoret, Jean-Paul
2017-01-01
Phytoplankton, with an estimated 30 000 to 1 000 000 species clustered in 12 phyla, presents a high taxonomic and ecophysiological diversity, reflected by the complex distribution of pigments among the different algal classes. High performance liquid chromatography is the gold standard method for qualitative and quantitative analysis of phytoplankton pigments in seawater and culture samples, but only a few pigments can be used as robust chemotaxonomic markers. A major challenge is thus to identify new ones, characteristic of a strain, species, class or taxon that cannot be currently identified on the basis of its pigment signature. Using an optimized extraction process coupled to a HPLC de-replication strategy, we examined the pigment composition of 37 microalgae strains, representative of the broad taxonomic diversity of marine and freshwater species (excluding cyanobacteria). For each species, the major pigments already described were unambiguously identified. We also observed the presence of several minor unidentified pigments in each chromatogram. The global analysis of pigment compositions revealed a total of 124 pigments, including 98 pigments or derivatives unidentified using the standards. Absorption spectra indicated that 35 corresponded to chlorophyll/porphyrin derivatives, 57 to carotenoids and six to derivatives having both spectral signatures. Sixty-one of these unidentified or new carotenoids and porphyrin derivatives were characteristic of particular strains or species, indicating their possible use as highly specific chemotaxonomic markers capable of identifying one strain out of the 37 selected. We developed a graphical analysis using Gephi software to give a clear representation of pigment communities among the various phytoplankton strains, and to reveal strain-characteristic and shared pigments. This made it possible to reconstruct the taxonomic evolution of microalgae classes, on the basis of the conservation, loss, and/or appearance of
NASA Astrophysics Data System (ADS)
Mattei, G.; Ahluwalia, A.
2018-04-01
We introduce a new function, the apparent elastic modulus strain-rate spectrum, E_{app} ( \\dot{ɛ} ), for the derivation of lumped parameter constants for Generalized Maxwell (GM) linear viscoelastic models from stress-strain data obtained at various compressive strain rates ( \\dot{ɛ}). The E_{app} ( \\dot{ɛ} ) function was derived using the tangent modulus function obtained from the GM model stress-strain response to a constant \\dot{ɛ} input. Material viscoelastic parameters can be rapidly derived by fitting experimental E_{app} data obtained at different strain rates to the E_{app} ( \\dot{ɛ} ) function. This single-curve fitting returns similar viscoelastic constants as the original epsilon dot method based on a multi-curve global fitting procedure with shared parameters. Its low computational cost permits quick and robust identification of viscoelastic constants even when a large number of strain rates or replicates per strain rate are considered. This method is particularly suited for the analysis of bulk compression and nano-indentation data of soft (bio)materials.
Metabolic Engineering of Synechocystis sp. Strain PCC 6803 for Isobutanol Production
Varman, Arul M.; Xiao, Yi; Pakrasi, Himadri B.
2013-01-01
Global warming and decreasing fossil fuel reserves have prompted great interest in the synthesis of advanced biofuels from renewable resources. In an effort to address these concerns, we performed metabolic engineering of the cyanobacterium Synechocystis sp. strain PCC 6803 to develop a strain that can synthesize isobutanol under both autotrophic and mixotrophic conditions. With the expression of two heterologous genes from the Ehrlich pathway, the engineered strain can accumulate 90 mg/liter of isobutanol from 50 mM bicarbonate in a gas-tight shaking flask. The strain does not require any inducer (i.e., isopropyl β-d-1-thiogalactopyranoside [IPTG]) or antibiotics to maintain its isobutanol production. In the presence of glucose, isobutanol synthesis is only moderately promoted (titer = 114 mg/liter). Based on isotopomer analysis, we found that, compared to the wild-type strain, the mutant significantly reduced its glucose utilization and mainly employed autotrophic metabolism for biomass growth and isobutanol production. Since isobutanol is toxic to the cells and may also be degraded photochemically by hydroxyl radicals during the cultivation process, we employed in situ removal of the isobutanol using oleyl alcohol as a solvent trap. This resulted in a final net concentration of 298 mg/liter of isobutanol under mixotrophic culture conditions. PMID:23183979
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramalingam, Rajinikumar
2010-04-09
Study of magnetostrictive effects in the bulk superconductors is very essential and can give more knowledge about the effects like namely, flux pinning induced strain, pincushion distortions in the magnets and so on. Currently used electro mechanical sensors are magnetic field dependent and can only give the global stress/strain information but not the local stress/strains. But the information like radius position dependent strain and characterisation of shape distortion in non cylindrical magnets are interesting. Wavelength encoded multiplexed fiber Bragg Grating sensors inscribed in one fiber gives the possibility to measure magentostrictive effects spatially resolved in low temperature and high magneticmore » field. This paper specifies the design and technology requirements to adapt FBG sensors for such an application. Also reports the experiments demonstrate the properties of glass FBG at low temperature (4.2 K) and the results of strain measurement at 4.2 K/8 T. The sensor exhibits a linear wavelength change for the strain change.« less
Genovese, Katia; Leeflang, Sander; Zadpoor, Amir A
2017-05-01
A custom-designed micro-digital image correlation system was used to track the evolution of the full-surface three-dimensional strain field of Ti6Al4V additively manufactured lattice samples under mechanical loading. The high-magnification capabilities of the method allowed to resolve the strain distribution down to the strut level and disclosed a highly heterogeneous mechanical response of the lattice structure with local strain concentrations well above the nominal global strain level. In particular, we quantified that strain heterogeneity appears at a very early stage of the deformation process and increases with load, showing a strain accumulation pattern with a clear correlation to the later onset of the fracture. The obtained results suggest that the unique opportunities offered by the proposed experimental method, in conjunction with analytical and computational models, could serve to provide novel important information for the rational design of additively manufactured porous biomaterials. Copyright © 2017 Elsevier Ltd. All rights reserved.
Highly stretchable miniature strain sensor for large dynamic strain measurement
Song, Bo; Yao, Shurong; Nie, Xu; ...
2016-01-01
In this paper, a new type of highly stretchable strain sensor was developed to measure large strains. The sensor was based on the piezo-resistive response of carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite thin films. The piezo-resistive response of CNT composite gives accurate strain measurement with high frequency response, while the ultra-soft PDMS matrix provides high flexibility and ductility for large strain measurement. Experimental results show that the CNT/PDMS sensor measures large strains (up to 8 %) with an excellent linearity and a fast frequency response. The new miniature strain sensor also exhibits much higher sensitivities than the conventional foil strain gages,more » as its gauge factor is 500 times of that of the conventional foil strain gages.« less
Bioprocessing of Stichococcus bacillaris strain siva2011
2014-01-01
Background Globally, the development of a cost-effective long-term renewable energy infrastructure is one of the most challenging problems faced by society today. Microalgae are rich in potential biofuel substrates such as lipids, including triacylglycerols (TAGs). Some of these algae also biosynthesize small molecule hydrocarbons. These hydrocarbons can often be used as liquid fuels, often with more versatility and by a more direct approach than some TAGs. However, the appropriate TAGs, accumulated from microalgae biomass, can be used as substrates for different kinds of renewable liquid fuels such as biodiesel and jet fuel. Results This article describes the isolation and identification of a lipid-rich, hydrocarbon-producing alga, Stichococcus bacillaris strain siva2011, together with its bioprocessing, hydrocarbon and fatty acid methyl ester (FAME) profiles. The S. bacillaris strain siva2011 was scaled-up in an 8 L bioreactor with 0.2% CO2. The C16:0, C16:3, C18:1, C18:2 and C18:3 were 112.2, 9.4, 51.3, 74.1 and 69.2 mg/g dry weight (DW), respectively. This new strain produced a significant amount of biomass of 3.79 g/L DW on day 6 in the 8 L bioreactor and also produced three hydrocarbons. Conclusions A new oil-rich microalga S. bacillaris strain siva2011 was discovered and its biomass has been scaled-up in a newly designed balloon-type bioreactor. The TAGs and hydrocarbons produced by this organism could be used as substrates for jet fuel or biodiesel. PMID:24731690
Bioprocessing of Stichococcus bacillaris strain siva2011.
Sivakumar, Ganapathy; Jeong, Kwangkook; Lay, Jackson O
2014-01-01
Globally, the development of a cost-effective long-term renewable energy infrastructure is one of the most challenging problems faced by society today. Microalgae are rich in potential biofuel substrates such as lipids, including triacylglycerols (TAGs). Some of these algae also biosynthesize small molecule hydrocarbons. These hydrocarbons can often be used as liquid fuels, often with more versatility and by a more direct approach than some TAGs. However, the appropriate TAGs, accumulated from microalgae biomass, can be used as substrates for different kinds of renewable liquid fuels such as biodiesel and jet fuel. This article describes the isolation and identification of a lipid-rich, hydrocarbon-producing alga, Stichococcus bacillaris strain siva2011, together with its bioprocessing, hydrocarbon and fatty acid methyl ester (FAME) profiles. The S. bacillaris strain siva2011 was scaled-up in an 8 L bioreactor with 0.2% CO2. The C16:0, C16:3, C18:1, C18:2 and C18:3 were 112.2, 9.4, 51.3, 74.1 and 69.2 mg/g dry weight (DW), respectively. This new strain produced a significant amount of biomass of 3.79 g/L DW on day 6 in the 8 L bioreactor and also produced three hydrocarbons. A new oil-rich microalga S. bacillaris strain siva2011 was discovered and its biomass has been scaled-up in a newly designed balloon-type bioreactor. The TAGs and hydrocarbons produced by this organism could be used as substrates for jet fuel or biodiesel.
Bjornstad, Petter; Truong, Uyen; Pyle, Laura; Dorosz, Jennifer L.; Cree-Green, Melanie; Baumgartner, Amy; Coe, Gregory; Regensteiner, Judith G.; Reusch, Jane E.B.; Nadeau, Kristen J.
2016-01-01
Objective Diabetic cardiomyopathy is a major cause of morbidity, but limited data are available on early cardiac abnormalities in type 1 diabetes (T1D). We investigated differences in myocardial strain in adolescents with and without T1D. We hypothesized that adolescents with T1D would have worse strain than their normoglycemic peers, which boys would have worse strain than girls, and that strain would correlate with glycemic control and adipokines. Methods We performed fasting laboratory measures and echocardiograms with speckle tracking to evaluate traditional echocardiographic measures in addition to longitudinal (LS) and circumferential (CS) strain, and in adolescents (15±2 years) with (19 boys; 22 girls) and without (16 boys; 32 girls) type 1 diabetes. Results Compared to controls, adolescents with type 1 diabetes had significantly lower CS (−20.9 vs. −22.7%, p=0.02), but not LS (p=0.83). Boys with T1D had significantly lower LS than girls with T1D (−17.5 vs. −19.7%, p=0.047), adjusted for Tanner stage. The significant sex differences observed in indexed left ventricular mass, left end-diastolic volume, diastolic septal and posterior wall thickness in our controls were lacking in adolescents with T1D. Conclusions Our observations suggest that youth with T1D have worse myocardial strain than normoglycemic peers. In addition, the relatively favorable cardiac profile observed in girls vs. boys in the control group, was attenuated in T1D. These early cardiovascular changes in youth with T1D are concerning and warrant longitudinal and mechanistic studies. PMID:27133451
Two ply tubular scaffolds comprised of proteins/poliglecaprone/polycaprolactone fibers.
Zhang, Xing; Thomas, Vinoy; Vohra, Yogesh K
2010-02-01
Electrospun bi-layer tubular hybrid scaffolds composed of poliglecaprone (PGC), polycaprolactone (PCL), elastin (E), and gelatin (G) were prepared and thereafter crosslinked by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC). Scanning electron microscopic (SEM) images revealed a highly porous micro-structure comprising randomly distributed non-woven fibers with the majority of fibers in submicron diameters. The EDC-crosslinking yielded an average crosslinking degree of 40%. Uni-axial tensile test of hydrated scaffolds in both longitudinal and circumferential directions revealed tensile properties, comparable to those of native arteries. The graft (PGC:PCL = 1:3) did not demonstrate significant difference before and after EDC-crosslinking in tensile strength or % strain in either longitudinal or circumferential directions. However, crosslinking increased the Young's modulus of the graft along the longitudinal direction (from 5.84 to 8.67 MPa). On the contrary, the graft (3:1) demonstrated a significant decrease in maximum strain in both directions. Cyto-assay using human umbilical vein endothelial cells (HUVECs) showed excellent cell viability.
Ultrasonographic study of mechanosensory properties in human esophagus during mechanical distension
Larsen, Ejnar; Reddy, Hariprasad; Drewes, Asbjørn Mohr; Arendt-Nielsen, Lars; Gregersen, Hans
2006-01-01
AIM: To study the esophageal geometry and mechanosensation using endoscopic ultrasonography during volume-controlled ramp distensions in the distal esophagus. METHODS: Twelve healthy volunteers underwent distension of a bag. During distension up to moderate pain the sensory intensity was assessed on a visual analogue scale (VAS). The esophageal deformation in terms of multidimensional stretch ratios and strains was calculated at different volumes and VAS levels. Distensions were done before and during administration of the anti-cholinergic drug butylscopolamine. RESULTS: The stimulus-response (volume-VAS) curve did not differ without or with the administration of butylscopolamine. Analysis of stretch ratios demonstrated tensile stretch in circumferential direction, compression in radial direction and a small tensile stretch in longitudinal direction. A strain gradient existed throughout the esophageal wall with the largest circumferential deformation at the mucosal surface. The sensation intensity increased exponentially as function of the strains. CONCLUSION: The method provides information of esophageal deformation gradients that correlate to the sensation intensity. Hence, it can be used to study mechanosensation in the human esophagus. Further studies are needed to determine the exact deformation stimulus for the esophageal mechanoreceptors. PMID:16874864
Vallée, Martin
2013-01-01
The movement of tectonic plates leads to strain build-up in the Earth, which can be released during earthquakes when one side of a seismic fault suddenly slips with respect to the other. The amount of seismic strain release (or 'strain drop') is thus a direct measurement of a basic earthquake property, that is, the ratio of seismic slip over the dimension of the ruptured fault. Here the analysis of a new global catalogue, containing ~1,700 earthquakes with magnitude larger than 6, suggests that strain drop is independent of earthquake depth and magnitude. This invariance implies that deep earthquakes are even more similar to their shallow counterparts than previously thought, a puzzling finding as shallow and deep earthquakes are believed to originate from different physical mechanisms. More practically, this property contributes to our ability to predict the damaging waves generated by future earthquakes.
Mustapha, Mustapha M; Marsh, Jane W; Harrison, Lee H
2016-03-18
Following an outbreak in Mecca Saudi Arabia in 2000, meningococcal strains expressing capsular group W (W) emerged as a major cause of invasive meningococcal disease (IMD) worldwide. The Saudi Arabian outbreak strain (Hajj clone) belonging to the ST-11 clonal complex (cc11) is similar to W cc11 causing occasional sporadic disease before 2000. Since 2000, W cc11 has caused large meningococcal disease epidemics in the African meningitis belt and endemic disease in South America, Europe and China. Traditional molecular epidemiologic typing suggested that a majority of current W cc11 burden represented global spread of the Hajj clone. However, recent whole genome sequencing (WGS) analyses revealed significant genetic heterogeneity among global W cc11 strains. While continued spread of the Hajj clone occurs in the Middle East, the meningitis belt and South Africa have co-circulation of the Hajj clone and other unrelated W cc11 strains. Notably, South America, the UK, and France share a genetically distinct W cc11 strain. Other W lineages persist in low numbers in Europe, North America and the meningitis belt. In summary, WGS is helping to unravel the complex genomic epidemiology of group W meningococcal strains. Wider application of WGS and strengthening of global IMD surveillance is necessary to monitor the continued evolution of group W lineages. Copyright © 2016 Elsevier Ltd. All rights reserved.
Barker Rasmussen, Bastian; Fog Nielsen, Kristian; Machado, Henrique; Melchiorsen, Jette; Gram, Lone; Sonnenschein, Eva C.
2014-01-01
Bacterial quorum sensing (QS) and the corresponding signals, acyl homoserine lactones (AHLs), were first described for a luminescent Vibrio species. Since then, detailed knowledge has been gained on the functional level of QS; however, the abundance of AHLs in the family of Vibrionaceae in the environment has remained unclear. Three hundred and one Vibrionaceae strains were collected on a global research cruise and the prevalence and profile of AHL signals in this global collection were determined. AHLs were detected in 32 of the 301 strains using Agrobacterium tumefaciens and Chromobacterium violaceum reporter strains. Ethyl acetate extracts of the cultures were analysed by ultra-high performance liquid chromatography-high resolution mass spectrometry (MS) with automated tandem MS confirmation for AHLs. N-(3-hydroxy-hexanoyl) (OH-C6) and N-(3-hydroxy-decanoyl) (OH-C10) homoserine lactones were the most common AHLs found in 17 and 12 strains, respectively. Several strains produced a diversity of different AHLs, including N-heptanoyl (C7) HL. AHL-producing Vibrionaceae were found in polar, temperate and tropical waters. The AHL profiles correlated with strain phylogeny based on gene sequence homology, however not with geographical location. In conclusion, a wide range of AHL signals are produced by a number of clades in the Vibrionaceae family and these results will allow future investigations of inter- and intra-species interactions within this cosmopolitan family of marine bacteria. PMID:25419995
Estimating a Global Hydrological Carrying Capacity Using GRACE Observed Water Stress
NASA Astrophysics Data System (ADS)
An, K.; Reager, J. T.; Famiglietti, J. S.
2013-12-01
Global population is expected to reach 9 billion people by the year 2050, causing increased demands for water and potential threats to human security. This study attempts to frame the overpopulation problem through a hydrological resources lens by hypothesizing that observed groundwater trends should be directly attributed to human water consumption. This study analyzes the relationships between available blue water, population, and cropland area on a global scale. Using satellite data from NASA's Gravity Recovery and Climate Experiment (GRACE) along with land surface model data from the Global Land Data Assimilation System (GLDAS), a global groundwater depletion trend is isolated, the validity of which has been verified in many regional studies. By using the inherent distributions of these relationships, we estimate the regional populations that have exceeded their local hydrological carrying capacity. Globally, these populations sum to ~3.5 billion people that are living in presently water-stressed or potentially water-scarce regions, and we estimate total cropland is exceeding a sustainable threshold by about 80 million km^2. Key study areas such as the North China Plain, northwest India, and Mexico City were qualitatively chosen for further analysis of regional water resources and policies, based on our distributions of water stress. These case studies are used to verify the groundwater level changes seen in the GRACE trend . Tfor the many populous, arid regions of the world that have already begun to experience the strains of high water demand.he many populous, arid regions of the world have already begun to experience the strains of high water demand. It will take a global cooperative effort of improving domestic and agricultural use efficiency, and summoning a political will to prioritize environmental issues to adapt to a thirstier planet. Global Groundwater Depletion Trend (Mar 2003-Dec 2011)
Dynamics of a stochastic multi-strain SIS epidemic model driven by Lévy noise
NASA Astrophysics Data System (ADS)
Chen, Can; Kang, Yanmei
2017-01-01
A stochastic multi-strain SIS epidemic model is formulated by introducing Lévy noise into the disease transmission rate of each strain. First, we prove that the stochastic model admits a unique global positive solution, and, by the comparison theorem, we show that the solution remains within a positively invariant set almost surely. Next we investigate stochastic stability of the disease-free equilibrium, including stability in probability and pth moment asymptotic stability. Then sufficient conditions for persistence in the mean of the disease are established. Finally, based on an Euler scheme for Lévy-driven stochastic differential equations, numerical simulations for a stochastic two-strain model are carried out to verify the theoretical results. Moreover, numerical comparison results of the stochastic two-strain model and the deterministic version are also given. Lévy noise can cause the two strains to become extinct almost surely, even though there is a dominant strain that persists in the deterministic model. It can be concluded that the introduction of Lévy noise reduces the disease extinction threshold, which indicates that Lévy noise may suppress the disease outbreak.
Do weak global stresses synchronize earthquakes?
NASA Astrophysics Data System (ADS)
Bendick, R.; Bilham, R.
2017-08-01
Insofar as slip in an earthquake is related to the strain accumulated near a fault since a previous earthquake, and this process repeats many times, the earthquake cycle approximates an autonomous oscillator. Its asymmetric slow accumulation of strain and rapid release is quite unlike the harmonic motion of a pendulum and need not be time predictable, but still resembles a class of repeating systems known as integrate-and-fire oscillators, whose behavior has been shown to demonstrate a remarkable ability to synchronize to either external or self-organized forcing. Given sufficient time and even very weak physical coupling, the phases of sets of such oscillators, with similar though not necessarily identical period, approach each other. Topological and time series analyses presented here demonstrate that earthquakes worldwide show evidence of such synchronization. Though numerous studies demonstrate that the composite temporal distribution of major earthquakes in the instrumental record is indistinguishable from random, the additional consideration of event renewal interval serves to identify earthquake groupings suggestive of synchronization that are absent in synthetic catalogs. We envisage the weak forces responsible for clustering originate from lithospheric strain induced by seismicity itself, by finite strains over teleseismic distances, or by other sources of lithospheric loading such as Earth's variable rotation. For example, quasi-periodic maxima in rotational deceleration are accompanied by increased global seismicity at multidecadal intervals.
Tatte, Vaishali S; Chaphekar, Deepa; Gopalkrishna, Varanasi
2017-08-01
Group A rotaviruses (RVA) are the major enteric etiological agents of severe acute gastroenteritis among children globally. As G9 RVA now represents as one of the major human RVA genotypes, studies on full genome of this particular genotype are being carried out worldwide. So far, no such studies on G9P[8] RVAs have been reported from Pune, western part of India. Keeping in view of this, the study was undertaken to understand the degree of genetic diversity of the commonly circulating G9P[8] RVA strains. Rotavirus surveillance studies carried out earlier during the years 2009-2011 showed increase in the prevalence of G9P[8] RVAs. Representative G9P[8] RVA strains from the years 2009, 2010, and 2011 were selected for the study. In general, all the G9 RVA strains showed clustering in the globally circulating sublineage of the VP7 gene and showed nucleotide/amino acid identities of 96.8-99.7%/96.9-99.8% with global G9 RV strains. Full genome analysis, of all three RVAs in this study indicated Wa-like genotype constellation G9-P[8]-I1-R1-C1-M1-A1-N1-T1-E1-H1. Within the strains nucleotide/amino acid divergence of 0.1-3.4%/0.0-4.1% was noted in all the RVA structural and non-structural genes. In conclusion, the present study highlights intra-genotypic variations throughout the RVA genome. The study further emphasizes the need for surveillance and analysis of the whole genomic constellation of the commonly circulating RVA strains of other regions in the country for understanding to a greater degree of the impact of rotavirus vaccination recently introduced in India. © 2017 Wiley Periodicals, Inc.
Nyaga, Martin M; Tan, Yi; Seheri, Mapaseka L; Halpin, Rebecca A; Akopov, Asmik; Stucker, Karla M; Fedorova, Nadia B; Shrivastava, Susmita; Duncan Steele, A; Mwenda, Jason M; Pickett, Brett E; Das, Suman R; Jeffrey Mphahlele, M
2018-05-18
Rotavirus A (RVA) exhibits a wide genotype diversity globally. Little is known about the genetic composition of genotype P[6] from Africa. This study investigated possible evolutionary mechanisms leading to genetic diversity of genotype P[6] VP4 sequences. Phylogenetic analyses on 167 P[6] VP4 full-length sequences were conducted, which included six porcine-origin sequences. Of the 167 sequences, 57 were newly acquired through whole genome sequencing as part of this study. The other 110 sequences were all publicly-available global P[6] VP4 full-length sequences downloaded from GenBank. The strength of association between the phenotypic features and the phylogeny was also determined. A number of reassortment and mixed infections of RVA genotype P[6] strains were observed in this study. Phylogenetic analyses demostrated the extensive genetic diversity that exists among human P[6] strains, porcine-like strains, their concomitant clades/subclades and estimated that P[6] VP4 gene has a higher substitution rate with the mean of 1.05E-3 substitutions/site/year. Further, the phylogenetic analyses indicated that genotype P[6] strains were endemic in Africa, characterised by an extensive genetic diversity and long-time local evolution of the viruses. This was also supported by phylogeographic clustering and G-genotype clustering of the P[6] strains when Bayesian Tip-association Significance testing (BaTS) was applied, clearly supporting that the viruses evolved locally in Africa instead of spatial mixing among different regions. Overall, the results demonstrated that multiple mechanisms such as reassortment events, various mutations and possibly interspecies transmission account for the enormous diversity of genotype P[6] strains in Africa. These findings highlight the need for continued global surveillance of rotavirus diversity. Copyright © 2018 Elsevier B.V. All rights reserved.
Han, Dongfei; Link, Hannes; Liesack, Werner
2017-08-11
Soil microorganisms have to rapidly respond to salt-induced osmotic stress. Type II methanotrophs of the genus Methylocystis are widely distributed in upland soils, but are known to have a low salt tolerance. Here, we tested the ability of Methylocystis sp. strain SC2 to adapt to increased salinity. When exposed to 0.75% NaCl, methane oxidation was completely inhibited for 2.25 h and fully recovered within 6 h. Growth was inhibited for 23.5 h and then fully recovered. Its transcriptome was profiled after 0 min (control), 45 min (early response) and 14 h (late response) of stress exposure. Physiological and transcriptomic stress response corresponded well. Salt stress induced differential expression of 301 genes, with sigma factor σ 32 being a major controller of the transcriptional stress response. The transcript levels of nearly all the genes involved in oxidizing CH 4 to CO 2 remained unaffected, while gene expression involved in energy-yielding reactions ( nuoEFGHI ) recovered concomitantly with methane oxidation from salt stress shock. Glutamate acted as an osmoprotectant. Its accumulation in late response corresponded to increased production of glutamate dehydrogenase 1. Chromosomal genes whose products (stress-induced protein, DNA-binding protein from starved cells, and CsbD family protein) are known to confer stress tolerance showed increased expression. On plasmid pBSC2-1, genes encoding type IV secretion system and single-strand DNA-binding protein were upregulated in late response, suggesting stress-induced activation of the plasmid-borne conjugation machinery. Collectively, our results show that Methylocystis sp. strain SC2 is able to adapt to salt stress, but only within a narrow range of salinities. Importance Besides the oxic interface of methanogenic environments, Methylocystis spp. are widely distributed in upland soils where they may contribute to the oxidation of atmospheric methane. However, little is known about their ability to cope with
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merkle, J.G.
In order to study effects of constraint on fracture toughness, it is important to select the right location within the crack-tip field for investigation. In 1950 Hill postulated that close to a circular notch tip the principal stress directions would be radial and circumferential, so that the plastic slip lines (maximum shear stress trajectories) would be logarithmic spirals. The resulting equation for stress normal to the notch symmetry plane, neglecting strain hardening, was identical to that for the circumferential stress near the bore of an ideally plastic thick-walled hollow cylinder under external radial tension, because the relevant geometries are identical.more » In 1969, Rice and Johnson developed a near crack-tip, plane strain, large-strain rigid-plastic analysis considering strain hardening and assuming an infinitely sharp initial crack tip. Shortly afterwards, Merkle, following Hill's suggestion, proposed an approximate analysis of the stresses and strains ahead of a blunted crack tip on the plane of symmetry, based on a circular blunted crack tip. The analysis amounted to a hollow cylinder analogy, including the effects of strain hardening. The original hollow cylinder analogy was based on small strain theory, and the calculated strain distributions did not agree well with the Rice and Johnson results very near the blunted crack tip. Therefore, the hollow cylinder analogy equations have been rederived, based on large strain theory, and the agreement with the Rice and Johnson results and other more recent numerical results is good. Calculations illustrate the effects of transverse strain on the principal stresses very close to a blunting crack tip and show that, theoretically, a singularity still exists at the tip of a blunting crack. 10 refs., 9 figs.« less
Measuring and interpreting borehole strainmeter data to improve CO2 storage
NASA Astrophysics Data System (ADS)
Murdoch, L. C.; DeWolf, S.; Germanovich, L. N.; Moysey, S. M.; Hanna, A. C.; Hu, J.; Plunkett, G.; Blais, R.; Johnson, W.
2017-12-01
Injecting fluids into a well deforms the enveloping rocks in a complex pattern that increases in magnitude and expands outward with time, and measurements of this strain field may be useful for monitoring the injection process. A pair of instruments capable of measuring four components of strain and two components of tilt has been developed. One instrument is designed to be removeable, whereas the other one is grouted in place. The removeable strainmeter provides versatility and lower cost because it can be relocated, whereas the grout-in instrument provides better coupling to the formation, which should improve the strain signal. The new strainmeters have been deployed along with a Gladwin strainmeter at the Avant Field, an oil field north of Tulsa, Oklahoma. Oil and water are being pumped out, and water is being injected in multiple boreholes that intersect the Bartlesville formation at a depth of approximately 500 m at the Avant Field. The strainmeters have been deployed at a depth of 30 m near well 9A, an injection well near the edge of the field. Results from a brief, 4-hr-long injection test into well 9A show that the radial and circumferential strain increase (become tensile) with time during injection, reaching a maximum of several 10s of nanostrain. In another example, data from the Gladwin strainmeter showed the strain field changing with time when an injection well 1 km away was shut-in. This caused the strain along a radial direction to become tensile, while the circumferential strain became compressive. This trend reversed a week later when injection into the well resumed. The major axis of the principle strain aligned with the shut-in well. The observed strain signals are similar to results from poroelastic analyses, and preliminary inverse analyses sugest that strain signals can be used to estimate reservoir characteristics at the Avant Field.
Heesakkers, John; Gerretsen, Reza; Izeta, Ander; Sievert, Karl-Dietrich; Farag, Fawzy
2016-02-01
The diagnosis of intrinsic sphincter deficiency (ISD) in patients with stress urinary incontinence (SUI) is not well established. We explored the possibility of applying a new tool: minimally invasive circumferential sphincter surface electromyography (CSS-EMG) to assess the muscular integrity of the urethral sphincter in patients with SUI/ISD. CSS-EMG of the urethral sphincter and urodynamic studies were performed in 44 women with SUI. A urethral pressure profile (UPP) was measured in four directions. Maximal urethral closure pressure (MUCP) <40 cm/H2 O or the presence of SUI without urethral hypermobility was used to define ISD. Twenty-one patients had urodynamic SUI, 23 had no SUI and 12 patients had ISD. The mean average rectified value (ARV) of the motor unit action potential (MUAP), an indicator of the strength of urethral rhabdosphincter, was estimated. ARV measured in the 12 o'clock quadrant during maximal contraction was the only CSS-EMG parameter that had significant predictive value for ISD. With an increase in the 12 o'clock ARV value, the likelihood of ISD decreases (Odds Ratio 0.36 95% confidence interval 0.67-0.92). In the ROC curve with ARV measured in the 12 o'clock quadrant during maximal contraction, the explained area was 0.794 (P = 0.02); implying that ARV measured at the 12 o'clock quadrant during maximal contraction was able to predict ISD significantly. Myogenic changes of the urethral sphincter that contribute to ISD can be assessed with CSS-EMG. This new concept for assessing the functionality of the female urethral sphincter may assist with better understanding of the pathophysiology, the diagnosis and the treatment of SUI. © 2014 Wiley Periodicals, Inc.
Grover, Davinder S; Smith, Oluwatosin; Fellman, Ronald L; Godfrey, David G; Gupta, Aditi; Montes de Oca, Ildamaris; Feuer, William J
2018-05-01
The purpose of this study was to provide 24-month follow-up on surgical success and safety of an ab interno circumferential 360-degree trabeculotomy. Chart review of patients who underwent a gonioscopy-assisted transluminal trabeculotomy (GATT) procedure was performed by 4 of the authors (D.S.G., O.S., R.L.F., and D.G.G.). The surgery was performed in adults with various types of open-angle glaucoma with preoperative intraocular pressures (IOPs) of ≥18 mm Hg. In total, 198 patients aged 24 to 89 years underwent the GATT procedure with at least 18 months follow-up. Patients with primary open-angle glaucoma had an average IOP decrease of 9.2 mm Hg at 24 months with an average decrease of 1.43 glaucoma medications. The mean percentage of IOP decrease in these primary open-angle glaucoma groups at 24 months was 37.3%. In secondary open-angle glaucoma, at 24 months there was an average decrease in IOP of 14.1 mm Hg on an average of 2.0 fewer medications. The mean percentage of IOP decrease in the secondary open-angle glaucoma groups at 24 months was 49.8%. The cumulative proportion of failure at 24 months ranged from 0.18 to 0.48, depending on the group. In all 6 study groups, at all 5 postoperative time points (3, 6, 12, 18, and 24 mo) the mean IOP and reduction in glaucoma medications was significantly reduced from baseline (P<0.001) with the exception of one time point. The 24-month results demonstrate that GATT is relatively safe and effective in treating various forms of open-angle glaucoma. The long-term results for GATT are relatively equivalent to those previously reported for GATT and ab externo trabeculotomy studies.
Population growth and global security
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mumford, S.
A new threat to international and domestic security has emerged in the past three decades: uncontrolled world population growth. Current world population growth control efforts are ineffective. Unchecked growth will threaten global security by depleting food, energy, and other resources. Immigration is another complicating factor that is straining the carrying capacity of some overpopulated regions. Barriers to effective action include the desire of decision-makers to avoid the controversy of abortion and the role of the Catholic church in lobbying against birth control. (3 graphs, 12 photos, 2 tables)
Improving industrial yeast strains: exploiting natural and artificial diversity
Steensels, Jan; Snoek, Tim; Meersman, Esther; Nicolino, Martina Picca; Voordeckers, Karin; Verstrepen, Kevin J
2014-01-01
Yeasts have been used for thousands of years to make fermented foods and beverages, such as beer, wine, sake, and bread. However, the choice for a particular yeast strain or species for a specific industrial application is often based on historical, rather than scientific grounds. Moreover, new biotechnological yeast applications, such as the production of second-generation biofuels, confront yeast with environments and challenges that differ from those encountered in traditional food fermentations. Together, this implies that there are interesting opportunities to isolate or generate yeast variants that perform better than the currently used strains. Here, we discuss the different strategies of strain selection and improvement available for both conventional and nonconventional yeasts. Exploiting the existing natural diversity and using techniques such as mutagenesis, protoplast fusion, breeding, genome shuffling and directed evolution to generate artificial diversity, or the use of genetic modification strategies to alter traits in a more targeted way, have led to the selection of superior industrial yeasts. Furthermore, recent technological advances allowed the development of high-throughput techniques, such as ‘global transcription machinery engineering’ (gTME), to induce genetic variation, providing a new source of yeast genetic diversity. PMID:24724938
Mental strain among staff at medical rehabilitation clinics in Germany.
Koerner, Mirjam
2011-01-20
The aim of the study is to compare the frequency of mental strain effects on employees in somatic and psychosomatic rehabilitation clinics as well as between the different occupational groups. Associations between mental strain effects and working conditions, cooperation in the team and employee satisfaction are also investigated. The present study is cross-sectional with a descriptive-explorative design. It is composed of a survey with standardized questionnaires (Human Service Workload, Questionnaire on Teamwork and Questionnaire on Staff Satisfaction in Medical Rehabilitation) and global items, and was conducted among all employees of twelve rehabilitation teams (five somatic and seven psychosomatic rehabilitation clinics (n=549)). The response rate of the survey averaged 45% (n=252). One in four participants reported being emotionally exhausted. There were significantly more emotionally exhausted employees working in the psychosomatic (31%) than in the somatic rehabilitation clinics (16%) (X(2)=7.403, df=1, p<0.05), with physicians most frequently reporting emotional exhaustion (45%). The negative appraisal of mental strain effects is accompanied by negative values for cooperation in the team and employee satisfaction (r=-.38 to r=-.50, p<.001). There were mostly high correlations (r=-.503 to r=-.609) between the working conditions and the mental strain effects (emotional exhaustion, intrinsic motivation, dissatisfaction). The results clearly show that the employees in medical rehabilitation clinics have a high stress level at work, a situation which is also known in other health care organizations. Observations of strong associations between cooperation in the team and strain effects confirm the positive impact of social support in the daily work routine. Correlation between the subjective appraisal of working conditions and the impact of strain is mostly high. It can be assumed that the strain effects can be influenced positively with supportive team and
GPS Imaging of Time-Dependent Seasonal Strain in Central California
NASA Astrophysics Data System (ADS)
Kraner, M.; Hammond, W. C.; Kreemer, C.; Borsa, A. A.; Blewitt, G.
2016-12-01
Recently, studies are suggesting that crustal deformation can be time-dependent and nontectonic. Continuous global positioning system (cGPS) measurements are now showing how steady long-term deformation can be influenced by factors such as fluctuations in loading and temperature variations. Here we model the seasonal time-dependent dilatational and shear strain in Central California, specifically surrounding the Parkfield region and try to uncover the sources of these deformation patterns. We use 8 years of cGPS data (2008 - 2016) processed by the Nevada Geodetic Laboratory and carefully select the cGPS stations for our analysis based on the vertical position of cGPS time series during the drought period. In building our strain model, we first detrend the selected station time series using a set of velocities from the robust MIDAS trend estimator. This estimation algorithm is a robust approach that is insensitive to common problems such as step discontinuities, outliers, and seasonality. We use these detrended time series to estimate the median cGPS positions for each month of the 8-year period and filter displacement differences between these monthly median positions using a filtering technique called "GPS Imaging." This technique improves the overall robustness and spatial resolution of the input displacements for the strain model. We then model our dilatational and shear strain field for each month of time series. We also test a variety of a priori constraints, which controls the style of faulting within the strain model. Upon examining our strain maps, we find that a seasonal strain signal exists in Central California. We investigate how this signal compares to thermoelastic, hydrologic, and atmospheric loading models during the 8-year period. We additionally determine whether the drought played a role in influencing the seasonal signal.
NASA Astrophysics Data System (ADS)
Strader, Anne; Schorlemmer, Danijel; Beutin, Thomas
2017-04-01
The Global Earthquake Activity Rate Model (GEAR1) is a hybrid seismicity model, constructed from a loglinear combination of smoothed seismicity from the Global Centroid Moment Tensor (CMT) earthquake catalog and geodetic strain rates (Global Strain Rate Map, version 2.1). For the 2005-2012 retrospective evaluation period, GEAR1 outperformed both parent strain rate and smoothed seismicity forecasts. Since 1. October 2015, GEAR1 has been prospectively evaluated by the Collaboratory for the Study of Earthquake Predictability (CSEP) testing center. Here, we present initial one-year test results of the GEAR1, GSRM and GSRM2.1, as well as localized evaluation of GEAR1 performance. The models were evaluated on the consistency in number (N-test), spatial (S-test) and magnitude (M-test) distribution of forecasted and observed earthquakes, as well as overall data consistency (CL-, L-tests). Performance at target earthquake locations was compared between models using the classical paired T-test and its non-parametric equivalent, the W-test, to determine if one model could be rejected in favor of another at the 0.05 significance level. For the evaluation period from 1. October 2015 to 1. October 2016, the GEAR1, GSRM and GSRM2.1 forecasts pass all CSEP likelihood tests. Comparative test results show statistically significant improvement of GEAR1 performance over both strain rate-based forecasts, both of which can be rejected in favor of GEAR1. Using point process residual analysis, we investigate the spatial distribution of differences in GEAR1, GSRM and GSRM2 model performance, to identify regions where the GEAR1 model should be adjusted, that could not be inferred from CSEP test results. Furthermore, we investigate whether the optimal combination of smoothed seismicity and strain rates remains stable over space and time.
Hamlet, Sean M; Haggerty, Christopher M; Suever, Jonathan D; Wehner, Gregory J; Andres, Kristin N; Powell, David K; Zhong, Xiaodong; Fornwalt, Brandon K
2017-03-01
To determine the optimal respiratory navigator gating configuration for the quantification of left ventricular strain using spiral cine displacement encoding with stimulated echoes (DENSE) MRI. Two-dimensional spiral cine DENSE was performed on a 3 Tesla MRI using two single-navigator configurations (retrospective, prospective) and a combined "dual-navigator" configuration in 10 healthy adults and 20 healthy children. The adults also underwent breathhold DENSE as a reference standard for comparisons. Peak left ventricular strains, signal-to-noise ratio (SNR), and navigator efficiency were compared. Subjects also underwent dual-navigator gating with and without visual feedback to determine the effect on navigator efficiency. There were no differences in circumferential, radial, and longitudinal strains between navigator-gated and breathhold DENSE (P = 0.09-0.95) (as confidence intervals, retrospective: [-1.0%-1.1%], [-7.4%-2.0%], [-1.0%-1.2%]; prospective: [-0.6%-2.7%], [-2.8%-8.3%], [-0.3%-2.9%]; dual: [-1.6%-0.5%], [-8.3%-3.2%], [-0.8%-1.9%], respectively). The dual configuration maintained SNR compared with breathhold acquisitions (16 versus 18, P = 0.06). SNR for the prospective configuration was lower than for the dual navigator in adults (P = 0.004) and children (P < 0.001). Navigator efficiency was higher (P < 0.001) for both retrospective (54%) and prospective (56%) configurations compared with the dual configuration (35%). Visual feedback improved the dual configuration navigator efficiency to 55% (P < 0.001). When quantifying left ventricular strains using spiral cine DENSE MRI, a dual navigator configuration results in the highest SNR in adults and children. In adults, a retrospective configuration has good navigator efficiency without a substantial drop in SNR. Prospective gating should be avoided because it has the lowest SNR. Visual feedback represents an effective option to maintain navigator efficiency while using a dual
Hamlet, Sean M.; Haggerty, Christopher M.; Suever, Jonathan D.; Wehner, Gregory J.; Andres, Kristin N.; Powell, David K.; Fornwalt, Brandon K.
2016-01-01
Purpose To determine the optimal respiratory navigator gating configuration for the quantification of left ventricular strain using spiral cine displacement encoding with stimulated echoes (DENSE) MRI. Materials and Methods 2D spiral cine DENSE was performed on a 3T MRI using two single-navigator configurations (retrospective, prospective), and a combined “dual-navigator” configuration in 10 healthy adults and 20 healthy children. The adults also underwent breath-hold DENSE as a reference standard for comparisons. Peak left ventricular strains, signal-to-noise ratio (SNR) and navigator efficiency were compared. Subjects also underwent dual-navigator gating with and without visual feedback to determine the effect on navigator efficiency. Results There were no differences in circumferential, radial and longitudinal strains between navigator-gated and breath-hold DENSE (p=0.09–0.95) (as confidence intervals, retrospective: [−1.0%,1.1%],[−7.4%,2.0%],[−1.0%,1.2%]; prospective: [−0.6%,2.7%],[−2.8%,8.3%],[−0.3%,2.9%]; dual: [−1.6%,0.5%],[−8.3%,3.2%],[−0.8%,1.9%], respectively). The dual configuration maintained SNR compared to breath-hold acquisitions (16 vs. 18, p=0.06). SNR for the prospective configuration was lower than for the dual navigator in adults (p=0.004) and children (p<0.001). Navigator efficiency was higher (p<0.001) for both retrospective (54%) and prospective (56%) configurations compared to the dual configuration (35%). Visual feedback improved the dual configuration navigator efficiency to 55% (p<0.001). Conclusion When quantifying left ventricular strains using spiral cine DENSE MRI, a dual navigator configuration results in the highest SNR in adults and children. In adults, a retrospective configuration has good navigator efficiency without a substantial drop in SNR. Prospective gating should be avoided since it has the lowest SNR. Visual feedback represents an effective option to maintain navigator efficiency while using a dual
NASA Astrophysics Data System (ADS)
Nauleau, Pierre; Minonzio, Jean-Gabriel; Chekroun, Mathieu; Cassereau, Didier; Laugier, Pascal; Prada, Claire; Grimal, Quentin
2016-07-01
Our long-term goal is to develop an ultrasonic method to characterize the thickness, stiffness and porosity of the cortical shell of the femoral neck, which could enhance hip fracture risk prediction. To this purpose, we proposed to adapt a technique based on the measurement of guided waves. We previously evidenced the feasibility of measuring circumferential guided waves in a bone-mimicking phantom of a circular cross-section of even thickness. The goal of this study is to investigate the impact of the complex geometry of the femoral neck on the measurement of guided waves. Two phantoms of an elliptical cross-section and one phantom of a realistic cross-section were investigated. A 128-element array was used to record the inter-element response matrix of these waveguides. This experiment was simulated using a custom-made hybrid code. The response matrices were analyzed using a technique based on the physics of wave propagation. This method yields portions of dispersion curves of the waveguides which were compared to reference dispersion curves. For the elliptical phantoms, three portions of dispersion curves were determined with a good agreement between experiment, simulation and theory. The method was thus validated. The characteristic dimensions of the shell were found to influence the identification of the circumferential wave signals. The method was then applied to the signals backscattered by the superior half of constant thickness of the realistic phantom. A cut-off frequency and some portions of modes were measured, with a good agreement with the theoretical curves of a plate waveguide. We also observed that the method cannot be applied directly to the signals backscattered by the lower half of varying thicknesses of the phantom. The proposed approach could then be considered to evaluate the properties of the superior part of the femoral neck, which is known to be a clinically relevant site.
Regional nonuniformity of normal adult human left ventricle.
Bogaert, J; Rademakers, F E
2001-02-01
Regional nonuniformity is a feature of both diseased and normal left ventricles (LV). With the use of magnetic resonance (MR) myocardial tagging, we performed three-dimensional strain analysis on 87 healthy adults in local cardiac and fiber coordinate systems (radial, circumferential, longitudinal, and fiber strains) to characterize normal nonuniformities and to test the validity of wall thickening as a parameter of regional function. Regional morphology included wall thickness and radii of curvature measurements. With respect to transmural nonuniformity, subendocardial strains exceeded subepicardial strains. Going from base to apex, wall thickness and circumferential radii of curvature decreased, whereas longitudinal radii of curvature increased. All of the strains increased from LV base to apex, resulting in a higher ejection fraction (EF) at the apex than at the base (70.9 +/- 0.4 vs. 62.4 +/- 0.4%; means +/- SE, P < 0.0001). When we looked around the circumference of the ventricle, the anterior part of the LV was the flattest and thinnest and showed the largest wall thickening (46.6 +/- 1.2%) but the lowest EF (64.7 +/- 0.5%). The posterior LV wall was thicker, more curved, and showed a lower wall thickening (32.8 +/- 1.0%) but a higher EF (71.3 +/- 0.5%). The regional contribution of the LV wall to the ejection of blood is thus highly variable and is not fully characterized by wall thickening alone. Differences in regional LV architecture and probably local stress are possible explanations for this marked functional nonuniformity.
Predicting Cardiotoxic Effects of Carbon Monoxide Poisoning Using Speckle Tracking Echocardiography.
Saraçoğlu, Erhan; Vuruşkan, Ertan; Kılıç, Salih; Çekici, Yusuf; Onur, Bahaeddin; Arslan, Yavuz; Kılıç, Ertuğrul; Aykut, Ömer
2018-04-01
Carbon monoxide (CO) poisoning could cause significant cardiac injury. This study aimed to evaluate patients with CO poisoning by using speckle tracking echocardiography (STE), a potentially more sensitive technique, to identify left systolic ventricular dysfunction for the first time in the literature. Seventy-two patients who were exposed to CO poisoning were studied. Blood collection and echocardiography were performed at admission and after patients' discharge on days 10-15 (mean 12 days). Global longitudinal strain (GLS) and global circumferential strain (GCS) were calculated using STE. In order to find the normal strain levels and to compare it to the patient with CO poisoning, 35 healthy subjects were included in the study. Left ventricular ejection fraction was analyzed according to Simpson's method. Patients were divided into two groups based on their LVEF values. LVEF < 55%, Group 1 (n = 24); LVEF ≥ 55%, Group 2 (n = 48). The reduction in Group 1 strain levels decreased in correlation with LVEF (p < 0.001) while in Group 2, there were no significant changes in LVEF but strain levels were significantly reduced (p = 0.091; p < 0.001). Compared with the control group patients, admission GLS and GLC values of CO-poisoned patients were significantly low both in Group 1 and 2. On the contrary, no significant difference was observed when compared with follow-up GLS value. For prediction of CO cardiotoxicity, the cutoff value of GLS was ≥ - 19.1 with a sensitivity of 70.3% and a specificity of 100% [(AUC) 0.840, 95% (CI) 0.735-0.916; p < 0.001] in the ROC curve analyses. GLS was found as independent predictors of cardiotoxicity. Our study demonstrates the potential of using systolic strain values obtained using 2D-STE in determining cardiotoxicity due to CO poisoning. Speckle tracking echocardiography has the potential of demonstrating subtle LV systolic dysfunction even in CO poisoning patients with preserved EF.
NASA Astrophysics Data System (ADS)
Weiss, J. R.; Walters, R. J.; Wright, T. J.; Hussain, E.; González, P. J.; Hooper, A. J.
2017-12-01
Accurate and high-resolution measurements of interseismic crustal velocity and the strain-rate fields derived from these measurements are an important input for the assessment of earthquake hazard. However, most strain-rate estimation methods and associated seismicity forecasts rely heavily on Global Navigation Satellite System (GNSS) networks with sparse and heterogeneous spatial coverage, limiting both accuracy and resolution. Interferometric Synthetic Aperture Radar (InSAR) provides remotely-sensed observations of surface motion, with accuracy comparable to GNSS data, and with a spatial resolution of a few tens of meters. The recently launched Sentinel-1 (S1) radar satellites can measure deformation at the tectonic-plate scale and across slowly straining regions where earthquake hazard is poorly characterised. We are producing large-scale crustal velocity and strain-rate fields for the Alpine-Himalayan belt (AHB) by augmenting global GNSS data compilations with InSAR-derived surface velocities. We are also systematically processing S1 interferograms for the AHB and these products are freely available to the geoscience community. We focus on the Anatolian microplate, where we have used both Envisat and S1 data to measure crustal velocity. We address some of the challenges associated with merging the complementary geodetic datasets including reference-frame issues, treatment of uncertainties, and comparison of different velocity/strain-rate inversion methods. We use synthetic displacement fields to illustrate how inclusion of InSAR can aid in identifying features such as unmapped active faults and fault segments that are creeping. From our preliminary results for Anatolia, we investigate the spatial distribution of strain and variation of strain rates during the seismic cycle.
The impact of Global Warming on global crop yields due to changes in pest pressure
NASA Astrophysics Data System (ADS)
Battisti, D. S.; Tewksbury, J. J.; Deutsch, C. A.
2011-12-01
A billion people currently lack reliable access to sufficient food and almost half of the calories feeding these people come from just three crops: rice, maize, wheat. Insect pests are among the largest factors affecting the yield of these three crops, but models assessing the effects of global warming on crops rarely consider changes in insect pest pressure on crop yields. We use well-established relationships between temperature and insect physiology to project climate-driven changes in pest pressure, defined as integrated population metabolism, for the three major crops. By the middle of this century, under most scenarios, insect pest pressure is projected to increase by more than 50% in temperate areas, while increases in tropical regions will be more modest. Yield relationships indicate that the largest increases in insect pest pressure are likely to occur in areas where yield is greatest, suggesting increased strain on global food markets.
Development of intra-strain self-cloning procedure for breeding baker's yeast strains.
Nakagawa, Youji; Ogihara, Hiroyuki; Mochizuki, Chisato; Yamamura, Hideki; Iimura, Yuzuru; Hayakawa, Masayuki
2017-03-01
Previously reported self-cloning procedures for breeding of industrial yeast strains require DNA from other strains, plasmid DNA, or mutagenesis. Therefore, we aimed to construct a self-cloning baker's yeast strain that exhibits freeze tolerance via an improved self-cloning procedure. We first disrupted the URA3 gene of a prototrophic baker's yeast strain without the use of any marker gene, resulting in a Δura3 homozygous disruptant. Then, the URA3 gene of the parental baker's yeast strain was used as a selection marker to introduce the constitutive TDH3 promoter upstream of the PDE2 gene encoding high-affinity cyclic AMP phosphodiesterase. This self-cloning procedure was performed without using DNA from other Saccharomyces cerevisiae strains, plasmid DNA, or mutagenesis and was therefore designated an intra-strain self-cloning procedure. Using this self-cloning procedure, we succeeded in producing self-cloning baker's yeast strains that harbor the TDH3p-PDE2 gene heterozygously and homozygously, designated TDH3p-PDE2 hetero and TDH3p-PDE2 homo strains, respectively. These self-cloning strains expressed much higher levels of PDE2 mRNA than the parental strain and exhibited higher viability after freeze stress, as well as higher fermentation ability in frozen dough, when compared with the parental strain. The TDH3p-PDE2 homo strain was genetically more stable than the TDH3p-PDE2 hetero strain. These results indicate that both heterozygous and homozygous strains of self-cloning PDE2-overexpressing freeze-tolerant strains of industrial baker's yeast can be prepared using the intra-strain self-cloning procedure, and, from a practical viewpoint, the TDH3p-PDE2 homo strain constructed in this study is preferable to the TDH3p-PDE2 hetero strain for frozen dough baking. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Borrow, Ray; Alarcón, Pedro; Carlos, Josefina; Caugant, Dominique A; Christensen, Hannah; Debbag, Roberto; De Wals, Philippe; Echániz-Aviles, Gabriela; Findlow, Jamie; Head, Chris; Holt, Daphne; Kamiya, Hajime; Saha, Samir K; Sidorenko, Sergey; Taha, Muhamed-Kheir; Trotter, Caroline; Vázquez Moreno, Julio A; von Gottberg, Anne; Sáfadi, Marco A P
2017-04-01
The 2015 Global Meningococcal Initiative (GMI) meeting discussed the global importance of meningococcal disease (MD) and its continually changing epidemiology. Areas covered: Although recent vaccination programs have been successful in reducing incidence in many countries (e.g. Neisseria meningitidis serogroup [Men]C in Brazil, MenA in the African meningitis belt), new clones have emerged, causing outbreaks (e.g. MenW in South America, MenC in Nigeria and Niger). The importance of herd protection was highlighted, emphasizing the need for high vaccination uptake among those with the highest carriage rates, as was the need for boosters to maintain individual and herd protection following decline of immune response after primary immunization. Expert commentary: The GMI Global Recommendations for Meningococcal Disease were updated to include a recommendation to enable access to whole-genome sequencing as for surveillance, guidance on strain typing to guide use of subcapsular vaccines, and recognition of the importance of advocacy and awareness campaigns.
Noel, B.W.; Smith, D.L.; Sinha, D.N.
1988-06-28
A strain gage comprising a strained-layer superlattice crystal exhibiting piezoelectric properties is described. A substrate upon which such a strained-layer superlattice crystal has been deposited is attached to an element to be monitored for strain. A light source is focused on the superlattice crystal and the light reflected from, passed through, or emitted from the crystal is gathered and compared with previously obtained optical property data to determine the strain in the element. 8 figs.
2013-01-01
Background Recently, left ventricular (LV) strain distribution pattern has been assessed in several cardiac disease states. Tachycardia-induced cardiomyopathy (TIC) is an animal model of non-ischemic cardiomyopathy well characterized in terms of global LV dysfunction but with poor understanding of regional variability in LV function. We hypothesized that TIC induces specific changes in LV strain distribution pattern. Methods Twenty five adult mongrel conscious dogs were trained to lie down calmly for echocardiography. In seven selected dogs, we implanted pacing system for TIC induction under general anesthesia. We measured LV geometry and function, strains, and torsion before and after the development of TIC in awake non-sedated state. Results In 25 healthy dogs, all three types of normal strain significantly increased from base to apex (p <0.05), while a definite and recognizable twist could be measured due to presence of shear strain. In 7 dogs with TIC, marked changes in LV mechanics occurred throughout the cardiac cycle, resulting in decrease of strain (p <0.001), twist (p <0.05), and negative peak twist rate (p <0.05). Interestingly, the relative decrease of strain due to TIC was more pronounced in the apex (p < 0.001), with the radial strain decreasing the most (p < 0.05). Conclusion TIC is accompanied by decreased systolic LV strain and twist deformation, as well as loss of early diastolic recoil. In addition, the decrease of strain was more profound in the apex. This “reverse” distribution of LV strain may help us understand LV dysfunction in the presence of nonischemic etiology. PMID:24304622
Kusunose, Kenya; Zhang, Youhua; Mazgalev, Todor N; Thomas, James D; Popović, Zoran B
2013-12-05
Recently, left ventricular (LV) strain distribution pattern has been assessed in several cardiac disease states. Tachycardia-induced cardiomyopathy (TIC) is an animal model of non-ischemic cardiomyopathy well characterized in terms of global LV dysfunction but with poor understanding of regional variability in LV function. We hypothesized that TIC induces specific changes in LV strain distribution pattern. Twenty five adult mongrel conscious dogs were trained to lie down calmly for echocardiography. In seven selected dogs, we implanted pacing system for TIC induction under general anesthesia. We measured LV geometry and function, strains, and torsion before and after the development of TIC in awake non-sedated state. In 25 healthy dogs, all three types of normal strain significantly increased from base to apex (p <0.05), while a definite and recognizable twist could be measured due to presence of shear strain. In 7 dogs with TIC, marked changes in LV mechanics occurred throughout the cardiac cycle, resulting in decrease of strain (p <0.001), twist (p <0.05), and negative peak twist rate (p <0.05). Interestingly, the relative decrease of strain due to TIC was more pronounced in the apex (p < 0.001), with the radial strain decreasing the most (p < 0.05). TIC is accompanied by decreased systolic LV strain and twist deformation, as well as loss of early diastolic recoil. In addition, the decrease of strain was more profound in the apex. This "reverse" distribution of LV strain may help us understand LV dysfunction in the presence of nonischemic etiology.
NASA Astrophysics Data System (ADS)
Dunbar, John A.; Cook, Richard W.
2003-07-01
Existing methods for the palinspastic reconstruction of structure maps do not adequately account for heterogeneous rock strain and hence cannot accurately treat features such as fault terminations and non-cylindrical folds. We propose a new finite element formulation of the map reconstruction problem that treats such features explicitly. In this approach, a model of the map surface, with internal openings that honor the topology of the fault-gap network, is constructed of triangular finite elements. Both model building and reconstruction algorithms are guided by rules relating fault-gap topology to the kinematics of fault motion and are fully automated. We represent the total strain as the sum of a prescribed component of locally homogeneous simple shear and a minimum amount of heterogeneous residual strain. The region within which a particular orientation of simple shear is treated as homogenous can be as small as an individual element or as large as the entire map. For residual strain calculations, we treat the map surface as a hyperelastic membrane. A globally optimum reconstruction is found that unfolds the map while faithfully honoring assigned strain mechanisms, closes fault gaps without overlap or gap and imparts the least possible residual strain in the restored surface. The amount and distribution of the residual strain serves as a diagnostic tool for identifying mapping errors. The method can be used to reconstruct maps offset by any number of faults that terminate, branch and offset each other in arbitrarily complex ways.
Rothman, Ilene L
2014-01-01
The term Michelin tire baby (MTB), named for the cartoon mascot of the Michelin Tire Company, has been used to describe babies with multiple symmetric circumferential rings of folded skin. In those reported with this phenotype who had skin biopsies, pathology has shown nevus lipomatosis, smooth muscle hamartoma, degenerative collagen, and scarring. Others did not undergo biopsy or had normal skin. Many individuals with the MTB phenotype have had a variety of other congenital anomalies. I review the literature on MTB and the history of the designation Michelin tire baby Syndrome (MTBS). Because the term MTBS has been poorly defined or not defined at all, I propose strict criteria for diagnosis. In doing so, it is recommended that the syndrome be renamed to avoid further confusion. © 2014 Wiley Periodicals, Inc.
Levy, Philip T.; Sanchez, Aura; Machefsky, Aliza; Fowler, Susan; Holland, Mark R.; Singh, Gautam K.
2014-01-01
Background Establishment of the range of normal values and associated variations of two-dimensional speckle-tracking echocardiography (2DSTE) derived right ventricular (RV) strain is a prerequisite for its routine clinical application in children. The objectives of this study were to perform a meta-analysis of normal ranges of RV longitudinal strain measurements derived by 2DSTE in children and identify confounders that may contribute to differences in reported measures. Methods A systematic review was launched in PubMed, Embase, Scopus, Cochrane, and ClinicTrials.gov. Search hedges were created to cover the concepts of pediatrics, speckle-tracking echocardiography, and right heart ventricle. Two investigators independently identified and included studies if they reported the 2DSTE derived RV strain measures: RV peak global longitudinal strain (pGLS), systolic strain rate (pGLSRs), early diastolic strain rate (pGLSRe), late diastolic strain rate (pGLSRa), or segmental longitudinal strain at the apical, mid, and basal ventricular levels in healthy children. Quality and reporting of the studies were assessed. The weighted mean was estimated by using random-effects with 95% confidence intervals (CI), heterogeneity was assessed by the Cochran's Q statistic and the inconsistency index (I2), and publication bias was evaluated using funnel plots and the Egger test. Effects of demographic, clinical, equipment, and software variables were assessed in a meta-regression. Results The search identified 226 children from 10 studies. The reported normal mean values of pGLS among the studies varied from −20.80% to −34.10% (mean, −29.03%, 95%CI, −31.52% to −26.54%), pGLSRs varied from −1.30 to −2.40 1/sec (mean, −1.88, 95%CI, −2.10 to −1.59), pGLSRe ranged from 1.7 to 2.69 1/sec (mean, 2.34, 95%CI, 2.00 to 2.67) and pGLSRa ranged from 1.00 to 1.30 1/sec (mean, 1.18, 95% CI, 1.04 to 1.33). A significant base-to-apex segmental strain gradient (p <0.05) was
Global occurrence and heterogeneity of the Roseobacter-clade species Ruegeria mobilis
Sonnenschein, Eva C; Nielsen, Kristian F; D'Alvise, Paul; Porsby, Cisse H; Melchiorsen, Jette; Heilmann, Jens; Kalatzis, Panos G; López-Pérez, Mario; Bunk, Boyke; Spröer, Cathrin; Middelboe, Mathias; Gram, Lone
2017-01-01
Tropodithietic acid (TDA)-producing Ruegeria mobilis strains of the Roseobacter clade have primarily been isolated from marine aquaculture and have probiotic potential due to inhibition of fish pathogens. We hypothesized that TDA producers with additional novel features are present in the oceanic environment. We isolated 42 TDA-producing R. mobilis strains during a global marine research cruise. While highly similar on the 16S ribosomal RNA gene level (99–100% identity), the strains separated into four sub-clusters in a multilocus sequence analysis. They were further differentiated to the strain level by average nucleotide identity using pairwise genome comparison. The four sub-clusters could not be associated with a specific environmental niche, however, correlated with the pattern of sub-typing using co-isolated phages, the number of prophages in the genomes and the distribution in ocean provinces. Major genomic differences within the sub-clusters include prophages and toxin-antitoxin systems. In general, the genome of R. mobilis revealed adaptation to a particle-associated life style and querying TARA ocean data confirmed that R. mobilis is more abundant in the particle-associated fraction than in the free-living fraction occurring in 40% and 6% of the samples, respectively. Our data and the TARA data, although lacking sufficient data from the polar regions, demonstrate that R. mobilis is a globally distributed marine bacterial species found primarily in the upper open oceans. It has preserved key phenotypic behaviors such as the production of TDA, but contains diverse sub-clusters, which could provide new capabilities for utilization in aquaculture. PMID:27552638
Structurally compliant rocket engine combustion chamber: Experimental and analytical validation
NASA Technical Reports Server (NTRS)
Jankovsky, Robert S.; Arya, Vinod K.; Kazaroff, John M.; Halford, Gary R.
1994-01-01
A new, structurally compliant rocket engine combustion chamber design has been validated through analysis and experiment. Subscale, tubular channel chambers have been cyclically tested and analytically evaluated. Cyclic lives were determined to have a potential for 1000 percent increase over those of rectangular channel designs, the current state of the art. Greater structural compliance in the circumferential direction gave rise to lower thermal strains during hot firing, resulting in lower thermal strain ratcheting and longer predicted fatigue lives. Thermal, structural, and durability analyses of the combustion chamber design, involving cyclic temperatures, strains, and low-cycle fatigue lives, have corroborated the experimental observations.
2011-03-01
showed a similar response as its companion specimen, L510-No13. Figure 76 shows the circumferential distribution of shell strain at the collapse...Defence R&D Canada Canada’s leader in defence and National Security Science and Technology R & D pour Ia defense Canada Chef de file au Canada en
GLOBAL NON-SPHERICAL OSCILLATIONS IN THREE-DIMENSIONAL 4π SIMULATIONS OF THE H-INGESTION FLASH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herwig, Falk; Woodward, Paul R.; Lin, Pei-Hung
2014-09-01
We performed three-dimensional simulations of proton-rich material entrainment into {sup 12}C-rich He-shell flash convection and the subsequent H-ingestion flash that took place in the post-asymptotic giant branch star Sakurai's object. Observations of the transient nature and anomalous abundance features are available to validate our method and assumptions, with the aim of applying them to very low-metallicity stars in the future. We include nuclear energy feedback from H burning and cover the full 4π geometry of the shell. Runs on 768{sup 3} and 1536{sup 3} grids agree well with each other and have been followed for 1500 minutes and 1200 minutes.more » After an 850 minute long quiescent entrainment phase, the simulations enter into a global non-spherical oscillation that is launched and sustained by individual ignition events of H-rich fluid pockets. Fast circumferential flows collide at the antipode and cause the formation and localized ignition of the next H-overabundant pocket. The cycle repeats for more than a dozen times while its amplitude decreases. During the global oscillation, the entrainment rate increases temporarily by a factor of ≈100. Entrained entropy quenches convective motions in the upper layer until the burning of entrained H establishes a separate convection zone. The lower-resolution run hints at the possibility that another global oscillation, perhaps even more violent, will follow. The location of the H-burning convection zone agrees with a one-dimensional model in which the mixing efficiency is calibrated to reproduce the light curve. The simulations have been performed at the NSF Blue Waters supercomputer at NCSA.« less
Global Earth Response to Loading by Ocean Tide Models
NASA Technical Reports Server (NTRS)
Estes, R. H.; Strayer, J. M.
1979-01-01
Mathematical and programming techniques to numerically calculate Earth response to global semidiurnal and diurnal ocean tide models were developed. Global vertical crustal deformations were evaluated for M sub 2, S sub 2, N sub 2, K sub 2, K sub 1, O sub 1, and P sub 1 ocean tide loading, while horizontal deformations were evaluated for the M sub 2 tidal load. Tidal gravity calculations were performed for M sub 2 tidal loads, and strain tensor elements were evaluated for M sub 2 loads. The M sub 2 solution used for the ocean tide included the effects of self-gravitation and crustal loading.
Rise and Persistence of Global M1T1 Clone of Streptococcus pyogenes
Kotb, Malak
2008-01-01
The resurgence of severe invasive group A streptococcal infections in the 1980s is a typical example of the reemergence of an infectious disease. We found that this resurgence is a consequence of the diversification of particular strains of the bacteria. Among these strains is a highly virulent subclone of serotype M1T1 that has exhibited unusual epidemiologic features and virulence, unlike all other streptococcal strains. This clonal strain, commonly isolated from both noninvasive and invasive infection cases, is most frequently associated with severe invasive diseases. Because of its unusual prevalence, global spread, and increased virulence, we investigated the unique features that likely confer its unusual properties. In doing so, we found that the increased virulence of this clonal strain can be attributed to its diversification through phage mobilization and its ability to sense and adapt to different host environments; accordingly, the fittest members of this diverse bacterial community are selected to survive and invade host tissue. PMID:18826812
Regional and directional compliance of the healthy aorta: an ex vivo study in a porcine model.
Krüger, Tobias; Veseli, Kujtim; Lausberg, Henning; Vöhringer, Luise; Schneider, Wilke; Schlensak, Christian
2016-07-01
To gain differential knowledge about the physiological compliance and wall strength of the different regions of the aorta, including the ascending aorta, arch and descending aorta in both the circumferential and longitudinal directions, and to generate a hypothesis on the pathophysiological mechanisms that lead to Type A aortic dissection. Fresh tissue specimens from 22 ex vivo porcine aortas were analysed on a tensile tester. Regional and directional compliance, failure stress and failure strain were recorded. Aortic compliance appeared as a linear function of the natural logarithm (ln) of wall stress. Compliance significantly decreased along the length of the aorta. In the ascending aorta, longitudinal compliance significantly (P = 0.003) exceeded circumferential compliance, and the outer curvature was more compliant than the inner curvature (P = 0.03). In the descending aorta, this relationship is reversed: the circumferential compliance exceeded the longitudinal compliance, and the outer aspect was more compliant (P = 0.003). The median circumferential failure stress of all aortic segments was in the range of 2000-2750 kPa, whereas the longitudinal failure stress in the ascending aorta and the arch had values of 750-1000 kPa, which were significantly lower (P < 0.05). Surprisingly, the longitudinal failure stress of the inner aspect of the descending aorta was extraordinarily high (2000 kPa). Failure strain, similar to compliance, was highest in the ascending aorta and decreased along the aorta. The aorta appears to be a complex organ with distinct regional and directional differences in compliance and wall strength that is designed to effectively absorb the kinetic energy of cardiac systole and to cushion the momentum of systolic impact. Under normotensive conditions and a preconditioned physiological morphology, the aortic wall works in the steep part of the logarithmic strain-stress function; under hypertensive conditions and pathological morphology, the
Strain release along ocean transform faults
NASA Astrophysics Data System (ADS)
Stewart, L. M.
A global study of the nature of seismic rupture along oceanic transform faults (TFs) is presented, and many aspects of fault behavior and Mid-Ocean Ridge processes are discussed. A classification of TF earthquakes is developed based on their relative excitation of short period body waves to long period surface waves. Since the ways in which transform faults release their accumulated strain varies, for more than 50 earthquakes occurring on 30 TFs since 1963 form the database for a comparison of rupture processes. The variation of TF rupture processes is not related to spreading rate or TF offset. A study of seismicity of the Eltanin Fracture Zone system shows that unlike many TFs, the Eltanin FZ realizes more than 90% of its slip aseismically. This identifies a major portion of plate boundary whose motion persists undetected by seismic instruments. The global variations in rupture patterns are discussed in terms of current models of fault behavior. The versatility of the asperity model accommodates the entire range of observed patterns. Variations in physical properties within TF contact zones (asperities) are documented in the petrology and geochemistry of rocks from ophiolite sections and TFs.
Measurement of high temperature strain by the laser-speckle strain gauge
NASA Technical Reports Server (NTRS)
Yamaguchi, I.
1984-01-01
By using the laser-speckle strain gauge, the strain of metal at the temperature lower than 250 C is measured. The principle of the gauge is to measure the expansion or contraction of the fine structures of surface by detecting the resultant speckle displacement in an optoelectronic way, whereby the effect of rigid-body motion is automatically cancelled out with the aid of a differential detection system. A transportable apparatus was built and a comparison experiment performed with a resistance strain gauge at room temperature. It has a strain sensitivity of .00002, a gauge length smaller than 1 mm, and no upper limit in a range of strain measurement. In the measurement of high-temperature strain it is free from the need for a dummy gauge and insensitive to an electric drift effect. As examples of strain measurement at high-temperature, thermal expansion and contraction of a top of a soldering iron are measured. The interval of the measurement can be made at shortest 1.6 sec. and the change in the strain is clearly followed until the ultimate stationary temperature is reached.
Castillo, Daniel; Pérez-Reytor, Diliana; Plaza, Nicolás; Ramírez-Araya, Sebastián; Blondel, Carlos J.; Corsini, Gino; Bastías, Roberto; Loyola, David E.; Jaña, Víctor; Pavez, Leonardo; García, Katherine
2018-01-01
Vibrio parahaemolyticus is the leading cause of seafood-borne gastroenteritis worldwide. As reported in other countries, after the rise and fall of the pandemic strain in Chile, other post-pandemic strains have been associated with clinical cases, including strains lacking the major toxins TDH and TRH. Since the presence or absence of tdh and trh genes has been used for diagnostic purposes and as a proxy of the virulence of V. parahaemolyticus isolates, the understanding of virulence in V. parahaemolyticus strains lacking toxins is essential to detect these strains present in water and marine products to avoid possible food-borne infection. In this study, we characterized the genome of four environmental and two clinical non-toxigenic strains (tdh-, trh-, and T3SS2-). Using whole-genome sequencing, phylogenetic, and comparative genome analysis, we identified the core and pan-genome of V. parahaemolyticus of strains of southern Chile. The phylogenetic tree based on the core genome showed low genetic diversity but the analysis of the pan-genome revealed that all strains harbored genomic islands carrying diverse virulence and fitness factors or prophage-like elements that encode toxins like Zot and RTX. Interestingly, the three strains carrying Zot-like toxin have a different sequence, although the alignment showed some conserved areas with the zot sequence found in V. cholerae. In addition, we identified an unexpected diversity in the genetic architecture of the T3SS1 gene cluster and the presence of the T3SS2 gene cluster in a non-pandemic environmental strain. Our study sheds light on the diversity of V. parahaemolyticus strains from the southern Pacific which increases our current knowledge regarding the global diversity of this organism. PMID:29472910
Iwamoto, Tomotada; Grandjean, Louis; Arikawa, Kentaro; Nakanishi, Noriko; Caviedes, Luz; Coronel, Jorge; Sheen, Patricia; Wada, Takayuki; Taype, Carmen A; Shaw, Marie-Anne; Moore, David A J; Gilman, Robert H
2012-01-01
Beijing family strains of Mycobacterium tuberculosis have attracted worldwide attention because of their wide geographical distribution and global emergence. Peru, which has a historical relationship with East Asia, is considered to be a hotspot for Beijing family strains in South America. We aimed to unveil the genetic diversity and transmission characteristics of the Beijing strains in Peru. A total of 200 Beijing family strains were identified from 2140 M. tuberculosis isolates obtained in Lima, Peru, between December 2008 and January 2010. Of them, 198 strains were classified into sublineages, on the basis of 10 sets of single nucleotide polymorphisms (SNPs). They were also subjected to variable number tandem-repeat (VNTR) typing using an international standard set of 15 loci (15-MIRU-VNTR) plus 9 additional loci optimized for Beijing strains. An additional 70 Beijing family strains, isolated between 1999 and 2006 in Lima, were also analyzed in order to make a longitudinal comparison. The Beijing family was the third largest spoligotyping clade in Peru. Its population structure, by SNP typing, was characterized by a high frequency of Sequence Type 10 (ST10), which belongs to a modern subfamily of Beijing strains (178/198, 89.9%). Twelve strains belonged to the ancient subfamily (ST3 [n=3], ST25 [n=1], ST19 [n=8]). Overall, the polymorphic information content for each of the 24 loci values was low. The 24 loci VNTR showed a high clustering rate (80.3%) and a high recent transmission index (RTI(n-1)=0.707). These strongly suggest the active and on-going transmission of Beijing family strains in the survey area. Notably, 1 VNTR genotype was found to account for 43.9% of the strains. Comparisons with data from East Asia suggested the genotype emerged as a uniquely endemic clone in Peru. A longitudinal comparison revealed the genotype was present in Lima by 1999.
Improving industrial yeast strains: exploiting natural and artificial diversity.
Steensels, Jan; Snoek, Tim; Meersman, Esther; Picca Nicolino, Martina; Voordeckers, Karin; Verstrepen, Kevin J
2014-09-01
Yeasts have been used for thousands of years to make fermented foods and beverages, such as beer, wine, sake, and bread. However, the choice for a particular yeast strain or species for a specific industrial application is often based on historical, rather than scientific grounds. Moreover, new biotechnological yeast applications, such as the production of second-generation biofuels, confront yeast with environments and challenges that differ from those encountered in traditional food fermentations. Together, this implies that there are interesting opportunities to isolate or generate yeast variants that perform better than the currently used strains. Here, we discuss the different strategies of strain selection and improvement available for both conventional and nonconventional yeasts. Exploiting the existing natural diversity and using techniques such as mutagenesis, protoplast fusion, breeding, genome shuffling and directed evolution to generate artificial diversity, or the use of genetic modification strategies to alter traits in a more targeted way, have led to the selection of superior industrial yeasts. Furthermore, recent technological advances allowed the development of high-throughput techniques, such as 'global transcription machinery engineering' (gTME), to induce genetic variation, providing a new source of yeast genetic diversity. © 2014 The Authors. FEMS Microbiology Reviews published by John Wiley & Sons Ltd on behalf of Federation of European Microbiological Societies.
Yang, Hong; Marwick, Thomas H; Fukuda, Nobuaki; Oe, Hiroki; Saito, Makoto; Thomas, James D; Negishi, Kazuaki
2015-06-01
Disagreement of strain measurements among different vendors has provided an obstacle to the clinical use of strain. A joint standardization task force between professional societies and industry was initiated to reduce intervendor variability of strain. Although feedback from this process has been used in software upgrades, little is known about the effects of efforts to improve conformity. The aim of this study was to assess whether intervendor agreement for global longitudinal strain (GLS) has improved after standardization initiatives. Eighty-two subjects (mean age, 52 ± 21 years; 55% men) prospectively underwent two sequential examinations using two most common ultrasound systems (Vivid E9 and iE33). GLS was calculated using proprietary software (EchoPAC-PC BT12 [E12] and BT13 [E13] vs QLAB version 8.0 [Q8], QLAB version 9.0 [Q9], and QLAB version 10.0 [Q10]). Agreements in GLS were evaluated with Bland-Altman plots. Coefficients of variation (CVs) were compared using the Friedman test and compared with CVs of left ventricular volumes and ejection fraction (LVEF). Median GLS using E12 was -19.2% (interquartile range [IQR], -15.2% to -23.2%), compared with -19.3% (IQR, -14.9% to -23.7%) for E13, -15.7% (IQR, -11.4% to -20%) for Q8, -19% (IQR, -15.7% to -22.3%) for Q9, and -18.7% (IQR, -15.7% to -21.7%) for Q10. The CVs of prestandardization GLS (12 ± 8% [E12/Q8] and 14 ± 8 [E13/Q8]) were significantly larger than that of LVEF (5 ± 5) (P < .001). Since standardization, the CVs of GLS have shown improvement (6 ± 4 [E12/Q9], 7 ± 4 [E12/Q10], 6 ± 4 [E13/Q9], and 7 ± 4 [E13/Q10]) and are similar to those of LVEF. Subsequent to the joint standardization task force, there has been improvement in between-vendor concordance in GLS between two leading ultrasound manufactures, the variability of which is now analogous to that of LVEF. The removal of concerns about measurement variability should allow wider use of GLS. Copyright © 2015 American
Iwano, Hiroyuki; Kamimura, Daisuke; Fox, Ervin R; Hall, Michael E; Vlachos, Pavlos; Little, William C
2016-12-01
Early-diastolic left ventricular (LV) longitudinal expansion is delayed with diastolic dysfunction. We hypothesized that, in patients with heart failure (HF), regardless of LV ejection fraction (EF), there is diastolic temporal nonuniformity with a delay of longitudinal relative to circumferential expansion. Echocardiography was performed in 143 HF patients-50 with preserved EF (HFpEF) and 93 with reduced EF (HFrEF)-as well as 31 normal control subjects. The delay of early-diastolic mitral annular velocity from the mitral Doppler E (T E-e' ) was measured as a parameter of the longitudinal expansion delay. The delay of the longitudinal early-diastolic global strain rate (SR E ) relative to circumferential SR E (Delay C-L ) was calculated as a parameter of temporal nonuniformity. Intra-LV pressure difference (IVPD) was estimated with the use of color M-mode Doppler data as a parameter of LV diastolic suction. Although normal control subjects had symmetric LV expansion in early diastole, T E-e' and Delay C-L were significantly prolonged in HF regardless of EF (P < .01 vs control for all). Multivariate analysis revealed that Delay C-L was the independent determinant of IVPD among the parameters of LV geometry and contraction (β = -0.21; P < .05). An abnormal temporal nonuniformity of early-diastolic expansion is present in HF regardless of EF, which was associated with reduced LV suction. Copyright © 2016 Elsevier Inc. All rights reserved.
Complete Genome Sequence of the Avian Pathogenic Escherichia coli Strain APEC O78
Mangiamele, Paul; Nicholson, Bryon; Wannemuehler, Yvonne; Seemann, Torsten; Logue, Catherine M.; Li, Ganwu; Tivendale, Kelly A.
2013-01-01
Colibacillosis, caused by avian pathogenic Escherichia coli (APEC), is a significant disease, causing extensive animal and financial losses globally. Because of the significance of this disease, more knowledge is needed regarding APEC's mechanisms of virulence. Here, we present the fully closed genome sequence of a typical avian pathogenic E. coli strain belonging to the serogroup O78. PMID:23516182
Michael Swyer
2015-02-22
Global Positioning System (GPS) time series from the National Science Foundation (NSF) Earthscope’s Plate Boundary Observatory (PBO) and Central Washington University’s Pacific Northwest Geodetic Array (PANGA). GPS station velocities were used to infer strain rates using the ‘splines in tension’ method. Strain rates were derived separately for subduction zone locking at depth and block rotation near the surface within crustal block boundaries.
Maffessanti, Francesco; Prinzen, Frits W; Conte, Giulio; Regoli, François; Caputo, Maria Luce; Suerder, Daniel; Moccetti, Tiziano; Faletra, Francesco; Krause, Rolf; Auricchio, Angelo
2018-01-01
This study sought to test the accuracy of strain measurements based on anatomo-electromechanical mapping (AEMM) measurements compared with magnetic resonance imaging (MRI) tagging, to evaluate the diagnostic value of AEMM-based strain measurements in the assessment of myocardial viability, and the additional value of AEMM over peak-to-peak local voltages. The in vivo identification of viable tissue, evaluation of mechanical contraction, and simultaneous left ventricular activation is currently achieved using multiple complementary techniques. In 33 patients, AEMM maps (NOGA XP, Biologic Delivery Systems, Division of Biosense Webster, a Johnson & Johnson Company, Irwindale, California) and MRI images (Siemens 3T, Siemens Healthcare, Erlangen, Germany) were obtained within 1 month. MRI tagging was used to determine circumferential strain (E cc ) and delayed enhancement to obtain local scar extent (%). Custom software was used to measure E cc and local area strain (LAS) from the motion field of the AEMM catheter tip. Intertechnique agreement for E cc was good (R 2 = 0.80), with nonsignificant bias (0.01 strain units) and narrow limits of agreement (-0.03 to 0.06). Scar segments showed lower absolute strain amplitudes compared with nonscar segments: E cc (median [first to third quartile]: nonscar -0.10 [-0.15 to -0.06] vs. scar -0.04 [-0.06 to -0.02]) and LAS (-0.20 [-0.27 to -0.14] vs. -0.09 [-0.14 to -0.06]). AEMM strains accurately discriminated between scar and nonscar segments, in particular LAS (area under the curve: 0.84, accuracy = 0.76), which was superior to peak-to-peak voltages (nonscar 9.5 [6.5 to 13.3] mV vs. scar 5.6 [3.4 to 8.3] mV; area under the curve: 0.75). Combination of LAS and peak-to-peak voltages resulted in 86% accuracy. An integrated AEMM approach can accurately determine local deformation and correlates with the scar extent. This approach has potential immediate application in the diagnosis, delivery of intracardiac therapies, and their
Circulation of a type 1 recombinant vaccine-derived poliovirus strain in a limited area in Romania.
Combiescu, M; Guillot, S; Persu, A; Baicus, A; Pitigoi, D; Balanant, J; Oprisan, G; Crainic, R; Delpeyroux, F; Aubert-Combiescu, A
2007-01-01
After intensive immunisation campaigns with the oral polio vaccine (OPV) as part of the Global Polio Eradication Initiative, poliomyelitis due to wild viruses has disappeared from most parts of the world, including Europe. Here, we report the characterization of a serotype 1 vaccine-derived poliovirus (VDPV) isolated from one acute flaccid paralysis (AFP) case with tetraplegia and eight healthy contacts belonging to the same small socio-cultural group having a low vaccine coverage living in a small town in Romania. The genomes of the isolated strains appeared to be tripartite type 1/type 2/type 1 vaccine intertypic recombinant genomes derived from a common ancestor strain. The presence of 1.2% nucleotide substitutions in the VP1 capsid protein coding region of most of the strains indicated a circulation time of about 14 months. These VDPVs were thermoresistant and, in transgenic mice expressing the human poliovirus receptor, appeared to have lost the attenuated phenotype. These results suggest that small populations with low vaccine coverage living in globally well-vaccinated countries can be the origin of VDPV emergence and circulation. These results reaffirm the importance of active surveillance for acute flaccid paralysis and poliovirus in both polio-free and polio-endemic countries.
Deus, K. M.; Saavedra-rodriguez, K.; Butters, M. P.; Black, W. C.; Foy, B. D.
2014-01-01
Seven different strains of Aedes aegypti (L.), including a genetically diverse laboratory strain, three laboratory-selected permethrin-resistant strains, a standard reference strain, and two recently colonized strains were fed on human blood containing various concentrations of ivermectin. Ivermectin reduced adult survival, fecundity, and hatch rate of eggs laid by ivermectin-treated adults in all seven strains. The LC50 of ivermectin for adults and the concentration that prevented 50% of eggs from hatching was calculated for all strains. Considerable variation in adult survival after an ivermectin-bloodmeal occurred among strains, and all three permethrin-resistant strains were significantly less susceptible to ivermectin than the standard reference strain. The hatch rate after an ivermectin bloodmeal was less variable among strains, and only one of the permethrin-resistant strains differed significantly from the standard reference strain. Our studies suggest that ivermectin induces adult mortality and decreases the hatch rate of eggs through different mechanisms. A correlation analysis of log-transformed LC50 among strains suggests that permethrin and ivermectin cross-resistance may occur. PMID:22493855
Global mapping of transposon location.
Gabriel, Abram; Dapprich, Johannes; Kunkel, Mark; Gresham, David; Pratt, Stephen C; Dunham, Maitreya J
2006-12-15
Transposable genetic elements are ubiquitous, yet their presence or absence at any given position within a genome can vary between individual cells, tissues, or strains. Transposable elements have profound impacts on host genomes by altering gene expression, assisting in genomic rearrangements, causing insertional mutations, and serving as sources of phenotypic variation. Characterizing a genome's full complement of transposons requires whole genome sequencing, precluding simple studies of the impact of transposition on interindividual variation. Here, we describe a global mapping approach for identifying transposon locations in any genome, using a combination of transposon-specific DNA extraction and microarray-based comparative hybridization analysis. We use this approach to map the repertoire of endogenous transposons in different laboratory strains of Saccharomyces cerevisiae and demonstrate that transposons are a source of extensive genomic variation. We also apply this method to mapping bacterial transposon insertion sites in a yeast genomic library. This unique whole genome view of transposon location will facilitate our exploration of transposon dynamics, as well as defining bases for individual differences and adaptive potential.
Factors affecting finite strain estimation in low-grade, low-strain clastic rocks
NASA Astrophysics Data System (ADS)
Pastor-Galán, Daniel; Gutiérrez-Alonso, Gabriel; Meere, Patrick A.; Mulchrone, Kieran F.
2009-12-01
The computer strain analysis methods SAPE, MRL and DTNNM have permitted the characterization of finite strain in two different regions with contrasting geodynamic scenarios; (1) the Talas Ala Tau (Tien Shan, Kyrgyzs Republic) and (2) the Somiedo Nappe and Narcea Antiform (Cantabrian to West Asturian-Leonese Zone boundary, Variscan Belt, NW of Iberia). The performed analyses have revealed low-strain values and the regional strain trend in both studied areas. This study also investigates the relationship between lithology (grain size and percentage of matrix) and strain estimates the two methodologies used. The results show that these methods are comparable and the absence of significant finite strain lithological control in rocks deformed under low metamorphic and low-strain conditions.
Nakamura, Kohki; Naito, Shigeto; Sasaki, Takehito; Minami, Kentaro; Take, Yutaka; Shimizu, Satoru; Yamaguchi, Yoshiaki; Yano, Toshiaki; Senga, Michiharu; Yamashita, Eiji; Sugai, Yoshinao; Kumagai, Koji; Funabashi, Nobusada; Oshima, Shigeru
2016-12-01
We aimed to identify the predictors of chronic pulmonary vein reconnections (CPVRs) after contact force (CF)-guided circumferential PV isolation (CPVI) of atrial fibrillation (AF). Forty-nine consecutive patients undergoing second ablation procedures for recurrent AF after CF-guided ablation were retrospectively studied. The CPVI was performed by point-by-point ablation with a target CF of 15-20 g. The incidence of CPVRs was evaluated along the right- and left-sided anterior and posterior CPVI regions (Ant-RPVs, Post-RPVs, Ant-LPVs, and Post-LPVs). CPVRs were observed in 30.6, 22.4, 20.4, and 32.7 % of patients along the Ant-RPVs, Post-RPVs, Ant-LPVs, and Post-LPVs, respectively (P = 0.436). In the multivariate logistic analyses, completing a left atrium-PV conduction block with touch-up ablation inside the initially estimated CPVI lines (Ant-RPVs, Post-RPVs, Ant-LPVs, Post-LPVs; odds ratio [OR] 5.747, 15.000, 207.619, 7.940; P = 0.032, 0.004, 0.034, 0.021) and region length (Post-LPVs; OR 3.183, P = 0.027) were positive predictors of CPVRs, while the mean CF (Ant-RPVs; OR 0.861, P = 0.045) and number of radiofrequency applications per unit length (Ant-LPVs, Post-LPVs; OR 0.038, 0.122; P = 0.034, 0.029) were negative predictors. At optimal cutoffs of 5.8 cm for the region length, 14.2 g for the mean CF, and 1.97/cm (Ant-LPVs) and 2.01/cm (Post-LPVs) for the radiofrequency application density, the sensitivity and specificity were 93.8 and 63.6 %, 60.0 and 76.5 %, 90.0 and 64.1 %, and 75.0 and 63.6 %, respectively. Completing PVI with circumferential lines without touch-up ablation and creating a sufficient density of radiofrequency ablation lesions on the lines with a sufficient CF may be necessary to prevent CPVRs after a CF-guided CPVI.