System and method for changing a glove attached to a glove box
Aluisi, Alan
2001-01-01
A system for changing the gloves of a glove box. The system requires the use of a new glove and a glove change ring to form a temporary secondary barrier to the exchange of atmospheres between the inner glove box and the room in which the glove box is operated. The system describes specific means for disengaging a used glove from the glove box port. The means for disengaging the used glove include use of a glove change hook and use of a glove with an attached tab for use in removal. A method for changing the gloves of a glove box is also described.
Can the design of glove dispensing boxes influence glove contamination?
Assadian, O; Leaper, D J; Kramer, A; Ousey, K J
2016-11-01
Few studies have explored the microbial contamination of glove boxes in clinical settings. The objective of this observational study was to investigate whether a new glove packaging system in which single gloves are dispensed vertically, cuff end first, has lower levels of contamination on the gloves and on the surface around the box aperture compared with conventional glove boxes. Seven participating sites were provided with vertical glove dispensing systems (modified boxes) and conventional boxes. Before opening glove boxes, the surface around the aperture was sampled microbiologically to establish baseline levels of superficial contamination. Once the glove boxes were opened, the first pair of gloves in each box was sampled for viable bacteria. Thereafter, testing sites were visited on a weekly basis over a period of six weeks and the same microbiological assessments were made. The surface near the aperture of the modified boxes became significantly less contaminated over time compared with the conventional boxes (P<0.001), with an average of 46.7% less contamination around the aperture. Overall, gloves from modified boxes showed significantly less colony-forming unit contamination than gloves from conventional boxes (P<0.001). Comparing all sites over the entire six-week period, gloves from modified boxes had 88.9% less bacterial contamination. This simple improvement to glove box design reduces contamination of unused gloves. Such modifications could decrease the risk of microbial cross-transmission in settings that use gloves. However, such advantages do not substitute for strict hand hygiene compliance and appropriate use of non-sterile, single-use gloves. Copyright © 2016 The Healthcare Infection Society. All rights reserved.
Butts, H.L.
1962-02-13
This invention comprises a housing unit to be fitted between a glove box port and a glove so that a slidable plate within the housing seals off the glove box port for evacuation of the glove box without damage to the glove. The housing and the glove may be evacuated without damage to the glove since movement of the glove is restricted during evacuation by the slidable plate. (AEC)
75 FR 38468 - Procurement List; Additions and Deletions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-02
...: 8415-00-NIB-0810--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Small. NSN: 8415-00-NIB-0811--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Medium. NSN: 8415-00-NIB-0812--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Large. NSN: 8415-00-NIB-0813--Glove, Vinyl...
75 FR 22744 - Procurement List: Proposed Additions and Deletions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
..., Industrial/Non-Medical Grade, 100 Gloves/Box, Small. NSN: 8415-00-NIB-0811--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Medium. NSN: 8415-00-NIB-0812--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Large. NSN: 8415-00-NIB-0813--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves...
A FLEXIBLE POLYTHENE GLOVE BOX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hughes, A.
1957-11-01
The need for a glove box capable of maintaining an inert atmosphere arose during the sampling and analysis of the alkali metals. The conventional rigid glove box was found to be unsuitable in practice and also inefficient in theory. The requirement was met by improvising a flexible glove box from thin polythene sheet. The alternative solution a this problem would have required an expensive vacuum glove box with its attendant pumping unit. (auth)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lemonds, David Preston
A breech lock for a glove box is provided that may be used to transfer one or more items into the glove box. The breech lock can be interchangeably installed in place of a plug, glove, or other device in a port or opening of a glove box. Features are provided to aid the removal of items from the breech lock by a gloved operator. The breech lock can be reused or, if needed, can be replaced with a plug, glove, or other device at the port or opening of the glove box.
Ballast system for maintaining constant pressure in a glove box
NASA Technical Reports Server (NTRS)
Shlichta, Paul J. (Inventor)
1989-01-01
A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.
Ballast system for maintaining constant pressure in a glove box
NASA Astrophysics Data System (ADS)
Shlichta, Paul J.
1989-09-01
A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.
Ballast system for maintaining constant pressure in a glove box
NASA Technical Reports Server (NTRS)
Shlichta, Paul J. (Inventor)
1990-01-01
A ballast system for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.
Bartsch, Adam J; Benzel, Edward C; Miele, Vincent J; Morr, Douglas R; Prakash, Vikas
2012-05-01
In spite of ample literature pointing to rotational and combined impact dosage being key contributors to head and neck injury, boxing and mixed martial arts (MMA) padding is still designed to primarily reduce cranium linear acceleration. The objects of this study were to quantify preliminary linear and rotational head impact dosage for selected boxing and MMA padding in response to hook punches; compute theoretical skull, brain, and neck injury risk metrics; and statistically compare the protective effect of various glove and head padding conditions. An instrumented Hybrid III 50th percentile anthropomorphic test device (ATD) was struck in 54 pendulum impacts replicating hook punches at low (27-29 J) and high (54-58 J) energy. Five padding combinations were examined: unpadded (control), MMA glove-unpadded head, boxing glove-unpadded head, unpadded pendulum-boxing headgear, and boxing glove-boxing headgear. A total of 17 injury risk parameters were measured or calculated. All padding conditions reduced linear impact dosage. Other parameters significantly decreased, significantly increased, or were unaffected depending on padding condition. Of real-world conditions (MMA glove-bare head, boxing glove-bare head, and boxing glove-headgear), the boxing glove-headgear condition showed the most meaningful reduction in most of the parameters. In equivalent impacts, the MMA glove-bare head condition induced higher rotational dosage than the boxing glove-bare head condition. Finite element analysis indicated a risk of brain strain injury in spite of significant reduction of linear impact dosage. In the replicated hook punch impacts, all padding conditions reduced linear but not rotational impact dosage. Head and neck dosage theoretically accumulates fastest in MMA and boxing bouts without use of protective headgear. The boxing glove-headgear condition provided the best overall reduction in impact dosage. More work is needed to develop improved protective padding to minimize linear and rotational impact dosage and develop next-generation standards for head and neck injury risk.
Small, Lightweight, Collapsible Glove Box
NASA Technical Reports Server (NTRS)
James, Jerry
2009-01-01
A small, lightweight, collapsible glove box enables its user to perform small experiments and other tasks. Originally intended for use aboard a space shuttle or the International Space Station (ISS), this glove box could also be attractive for use on Earth in settings in which work space or storage space is severely limited and, possibly, in which it is desirable to minimize weight. The development of this glove box was prompted by the findings that in the original space-shuttle or ISS setting, (1) it was necessary to perform small experiments in a large general-purpose work station, so that, in effect, they occupied excessive space; and it took excessive amounts of time to set up small experiments. The design of the glove box reflects the need to minimize the space occupied by experiments and the time needed to set up experiments, plus the requirement to limit the launch weight of the box and the space needed to store the box during transport into orbit. To prepare the glove box for use, the astronaut or other user has merely to insert hands through the two fabric glove ports in the side walls of the box and move two hinges to a locking vertical position (see figure). The user could do this while seated with the glove box on the user fs lap. When stowed, the glove box is flat and has approximately the thickness of two pieces of 8-in. (.20 cm) polycarbonate.
Glove box for water pit applications
Mills, William C [Richland, WA; Rabe, Richard A [North Fork, ID
2005-01-18
A glove box assembly that includes a glove box enclosure attached to a longitudinally extending hollow tube having an entranceway, wherein the portion of the tube is in a liquid environment. An elevator member is provided for raising an object that is introduced into the hollow tube from the liquid environment to a gas environment inside the glove box enclosure while maintaining total containment.
DEVELOPMENT OF A NEW GLOVE FOR GLOVE BOXES WITH HIGH-LEVEL PERFORMANCES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blancher, J.; Poirier, J.M.
2003-02-27
This paper describes the results of a joint technological program of COGEMA and MAPA to develop a new generation of glove for glove boxes. The mechanical strength of this glove is twice as high as the best characteristics of gloves available on the market. This new generation of product has both a higher level of performance and better ergonomics.
Brackenbush, L.W.; Hoenes, G.R.
A shield for a glove box housing radioactive material is comprised of spaced apart clamping members which maintain three overlapping flaps in place therebetween. There is a central flap and two side flaps, the side flaps overlapping at the interior edges thereof and the central flap extending past the intersection of the side flaps in order to insure that the shield is always closed when the user wthdraws his hand from the glove box. Lead loaded neoprene rubber is the preferred material for the three flaps, the extent of lead loading depending upon the radiation levels within the glove box.
A System for Cooling inside a Glove Box
ERIC Educational Resources Information Center
Sanz, Martial
2010-01-01
An easy, efficient, reliable, and low-cost method of constructing a cooling system using a simple circulating pump is described. The system is employed in conjunction with an inert atmosphere glove box to achieve the synthesis of air- and moisture-sensitive compounds inside the glove box at controlled, low temperatures without contaminating the…
NASA Technical Reports Server (NTRS)
Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)
2001-01-01
Neoprene gloves are used in a Space Shuttle Microgravity Glove Box (MGBX) experiment. In 1999, significant corrosion was observed in the work area and on the outer surface of the left glove ring. Analysis of the corrosion products showed that they contained chlorine. The Neoprene gloves used in this glove box were obtained in 1995, with a recommended shelf life of 3 years. After storage of these gloves in a cabinet drawer until 1999, significant signs of corrosion were also observed in the drawer. Mechanical and thermal properties were determined on samples cut from the finger and sleeve areas of the "good" and "bad" gloves. This data showed significant aging of the left-hand glove, particularly in the sleeve area. Thermal analysis data by DSC and TGA was complimentary to tensile data in showing this aging. However, this test data did not pinpoint the cause of the left-hand glove aging, or of the corrosion products.
Brackenbush, Larry W.; Hoenes, Glenn R.
1981-01-01
According to the present invention, a shield for a glove box housing radioactive material is comprised of spaced apart clamping members which maintain three overlapping flaps in place therebetween. There is a central flap and two side flaps, the side flaps overlapping at the interior edges thereof and the central flap extending past the intersection of the side flaps in order to insure that the shield is always closed when the user withdraws his hand from the glove box. Lead loaded neoprene rubber is the preferred material for the three flaps, the extent of lead loading depending upon the radiation levels within the glove box.
EVA Glove Sensor Feasbility II Abstract
NASA Technical Reports Server (NTRS)
Melone, Kate
2014-01-01
The main objectives for the glove project include taking various measurements from human subjects during and after they perform different tasks in the glove box, acquiring data from these tests and determining the accuracy of these results, interpreting and analyzing this data, and using the data to better understand how hand injuries are caused during EVAs.1 Some of these measurements include force readings, temperature readings, and micro-circulatory blood flow.1 The three glove conditions tested were ungloved (a comfort glove was worn to house the sensors), Series 4000, and Phase VI. The general approach/procedure for the glove sensor feasibility project is as follows: 1. Prepare test subject for testing. This includes attaching numerous sensors (approximately 50) to the test subject, wiring, and weaving the sensors and wires in the glove which helps to keep everything together. This also includes recording baseline moisture data using the Vapometer and MoistSense. 2. Pressurizing the glove box. Once the glove box is pressurized to the desired pressure (4.3 psid), testing can begin. 3. Testing. The test subject will perform a series of tests, some of which include pinching a load cell, making a fist, pushing down on a force plate, and picking up metal pegs, rotating them 90 degrees, and placing them back in the peg board. 4. Post glove box testing data collection. After the data is collected from inside the glove box, the Vapometer and MoistSense device will be used to collect moisture data from the subject's hand. 5. Survey. At the conclusion of testing, he/she will complete a survey that asks questions pertaining to comfort/discomfort levels of the glove, glove sizing, as well as offering any additional feedback.
9. VIEW, LOOKING WEST, OF GLOVE BOXES ASSOCIATED WITH THE ...
9. VIEW, LOOKING WEST, OF GLOVE BOXES ASSOCIATED WITH THE ANION EXCHANGE PROCESS IN ROOM 149. THE GLOVE BOXES ON THE LEFT CONTAIN MIXER STIRRERS THAT AID IN THE DISSOLUTION PROCESS THAT OCCURRED PRIOR TO ANION EXCHANGE. (6/20/60) - Rocky Flats Plant, Plutonium Recovery & Fabrication Facility, North-central section of plant, Golden, Jefferson County, CO
5. VIEW OF A GLOVE BOX FIREWALL DETAIL. THE FIREWALL ...
5. VIEW OF A GLOVE BOX FIREWALL DETAIL. THE FIREWALL WAS A SAFETY FEATURE TO PREVENT THE SPREAD OF FIRE BETWEEN INTERCONNECTED GLOVE BOXES. PLUTONIUM IS PYROPHORIC, AND MAY IGNITE IN THE PRESENCE OF OXYGEN. (5/8/70) - Rocky Flats Plant, Plutonium Manufacturing Facility, North-central section of Plant, just south of Building 776/777, Golden, Jefferson County, CO
NASA Astrophysics Data System (ADS)
Kumar, V. Suresh; Kumar, R.; Sivaraman, N.; Ravisankar, G.; Vasudeva Rao, P. R.
2010-09-01
The design and development of a novel supercritical extraction experimental facility adapted for safe operation in a glove box for the recovery of radioactive elements from waste is described. The apparatus incorporates a high pressure extraction vessel, reciprocating pumps for delivering supercritical fluid and reagent, a back pressure regulator, and a collection chamber. All these components of the system have been specially designed for glove box adaptation and made modular to facilitate their replacement. Confinement of these materials must be ensured in a glove box to protect the operator and prevent contamination to the work area. Since handling of radioactive materials under high pressure (30 MPa) and temperature (up to 333 K) is involved in this process, the apparatus needs elaborate safety features in the design of the equipment, as well as modification of a standard glove box to accommodate the system. As a special safety feature to contain accidental leakage of carbon dioxide from the extraction vessel, a safety vessel has been specially designed and placed inside the glove box. The extraction vessel was enclosed in the safety vessel. The safety vessel was also incorporated with pressure sensing and controlling device.
Rentetzi, Maria
2017-06-01
In a nuclear laboratory, a glove box is a windowed, sealed container equipped with two flexible gloves that allow the user to manipulate nuclear materials from the outside in an ostensibly safe environment. As a routine laboratory device, it invites neglect from historians and storytellers of science. Yet, since especially the Gulf War, glove boxes have put the interdependence of science, diplomacy, and politics into clear relief. Standing at the intersection of history of science and international history, technological materials and devices such as the glove box can provide penetrating insight into the role of international diplomatic organizations to the global circulation and control of scientific knowledge. The focus here is on the International Atomic Energy Agency. Copyright © 2017 The Author. Published by Elsevier Ltd.. All rights reserved.
7. Process areas room. Incinerator and glove boxes (hoods) to ...
7. Process areas room. Incinerator and glove boxes (hoods) to the right. Filter boxes to the left. Looking south. - Plutonium Finishing Plant, Waste Incinerator Facility, 200 West Area, Richland, Benton County, WA
Glove box on vehicular instrument panel
Atarashi, Kazuya
1985-01-01
A glove box for the upper surface of an automobile dashboard whereby it may be positioned close to the driver. The glove box lid is pivotally supported by arms extending down either side to swing forwardly for opening. A hook is pivotally support adjacent an arm and weighted to swing into engagement with the arm to prevent opening of the lid during abrupt deceleration. A toggle spring assists in maintaining the lid in either the open or closed position.
12. VIEW OF THE INSPECTION MODULE (MODULE D). THE GLOVE ...
12. VIEW OF THE INSPECTION MODULE (MODULE D). THE GLOVE BOX IN THE FOREFRONT OF THE PHOTOGRAPH CONTAINS A DRILL PRESS; OTHER GLOVE BOXES ARE USED FOR PARTS INSPECTION. (5/70) - Rocky Flats Plant, Plutonium Manufacturing Facility, North-central section of Plant, just south of Building 776/777, Golden, Jefferson County, CO
The Construction of the UCSC Econo-Box: An Inexpensive Yet Effective Glove Box
NASA Astrophysics Data System (ADS)
Suri, Jeff T.
2001-11-01
An inexpensive, acrylic dry (glove) box has been fabricated and utilized in the handling of water- and air-sensitive materials. Working drawings are provided and a complete layout of material costs is presented. The box was experimentally determined to be moisture-free for three days and critically oxygen-free for 20 minutes under an inert gas atmosphere.
Development of a prototype movement assistance system for extravehicular activity gloves
NASA Astrophysics Data System (ADS)
Hill, Tyler N.
Spacesuits utilized a rubberized layer of material to contain a pressurized atmosphere to facilitate respiration and maintain the physiologic functions of the astronaut residing within. However, the elasticity of the material makes it resistant to deformation increasing the amount of work required during movement. This becomes particularly fatiguing for the muscle groups controlling the motion of the hands and fingers. To mitigate this a robotic system was proposed and developed. The system built upon previous concepts and prototypes discovered through research efforts. It utilized electric motors to pull the index, ring, and middle fingers of the right hand closed, ideally overcoming the resistive force posed by the pressurized elastic material. The effect of the system was determined by comparing qualitative and quantitative data obtained during activities conducted with and without it within a glove box. It was found that the system was able to offload some of this elastic force though several characteristics of the design limited the full potential this device offered. None the less, the project was met with success and provides a solid platform for continued research and development.
1. VIEW OF A PORTION OF THE HYDRIDE PROCESSING LABORATORY. ...
1. VIEW OF A PORTION OF THE HYDRIDE PROCESSING LABORATORY. OPERATIONS IN THE GLOVE BOX IN THE BACKGROUND OF THE PHOTOGRAPH INCLUDED HYDRIDING OF PLUTONIUM AND HYDRIDE SEPARATION. IN THE FOREGROUND, THE VACUUM MONITOR CONTROL PANEL MEASURED TEMPERATURES WITHIN THE GLOVEBOX. THE CENTER CONTROL PANEL REGULATED THE FURNACE INSIDE THE GLOVE BOX USED IN THE HYDRIDING PROCESSES. THIS EQUIPMENT WAS ESSENTIAL TO THE HYDRIDING PROCESS, AS WELL AS OTHER GLOVE BOX OPERATIONS. - Rocky Flats Plant, Plutonium Laboratory, North-central section of industrial area at 79 Drive, Golden, Jefferson County, CO
2009-11-19
CAPE CANAVERAL, Fla. – At the Astronaut Hall of Fame near NASA’s Kennedy Space Center in Florida, Patrick Simpkins, director of Engineering at Kennedy, tries out a pair of space gloves for their dexterity and flexibility in a glove box at the 2009 Astronaut Glove Challenge, part of NASA’s Centennial Challenges Program. Looking over his shoulder is Kennedy Director Bob Cabana. The nationwide competition focused on developing improved pressure suit gloves for astronauts to use while working in space. During the challenge, the gloves were submitted to burst tests, joint force tests and tests to measure their dexterity and strength during operation in a glove box which simulates the vacuum of space. Centennial Challenges is NASA’s program of technology prizes for the citizen-inventor. The winning prize for the Glove Challenge is $250,000 provided by the Centennial Challenges Program. Photo credit: NASA/Kim Shiflett
8. Front (east) side of incinerator and glove boxes. Ash ...
8. Front (east) side of incinerator and glove boxes. Ash canning hood to the left, combustion chamber in the middle, incinerator hood to the right. Looking west. - Plutonium Finishing Plant, Waste Incinerator Facility, 200 West Area, Richland, Benton County, WA
2009-11-19
CAPE CANAVERAL, Fla. – At the Astronaut Hall of Fame near NASA’s Kennedy Space Center in Florida, Anna Heiney, a Public Affairs support writer with Abacus Technology at Kennedy, tries out a pair of space gloves for their dexterity and flexibility in a glove box at the 2009 Astronaut Glove Challenge, part of NASA’s Centennial Challenges Program. Looking over his shoulder is Kennedy Director Bob Cabana. The nationwide competition focused on developing improved pressure suit gloves for astronauts to use while working in space. During the challenge, the gloves were submitted to burst tests, joint force tests and tests to measure their dexterity and strength during operation in a glove box which simulates the vacuum of space. Centennial Challenges is NASA’s program of technology prizes for the citizen-inventor. The winning prize for the Glove Challenge is $250,000 provided by the Centennial Challenges Program. Photo credit: NASA/Kim Shiflett
Rosin-Rammler Distributions in ANSYS Fluent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunham, Ryan Q.
In Health Physics monitoring, particles need to be collected and tracked. One method is to predict the motion of potential health hazards with computer models. Particles released from various sources within a glove box can become a respirable health hazard if released into the area surrounding a glove box. The goal of modeling the aerosols in a glove box is to reduce the hazards associated with a leak in the glove box system. ANSYS Fluent provides a number of tools for modeling this type of environment. Particles can be released using injections into the flow path with turbulent properties. Themore » models of particle tracks can then be used to predict paths and concentrations of particles within the flow. An attempt to understand and predict the handling of data by Fluent was made, and results iteratively tracked. Trends in data were studied to comprehend the final results. The purpose of the study was to allow a better understanding of the operation of Fluent for aerosol modeling for future application in many fields.« less
14. VIEW OF THE OUTSIDE OF A GLOVE BOX THAT ...
14. VIEW OF THE OUTSIDE OF A GLOVE BOX THAT CONTAINS ELECTROREFINING EQUIPMENT. ELECTROREFINING WAS ONE OF THE PROCESSES USED TO PURIFY PLUTONIUM THAT DID NOT MEET PURITY SPECIFICATIONS. (10/25/66) - Rocky Flats Plant, Plutonium Fabrication, Central section of Plant, Golden, Jefferson County, CO
Code of Federal Regulations, 2010 CFR
2010-07-01
... ACM from straight runs of piping and elbows and other connections with the following specifications... or other device used to prevent collapse of bag during removal shall run continually during the... pressure glove box systems. Negative pressure glove boxes may be used to remove ACM or PACM from pipe runs...
Code of Federal Regulations, 2014 CFR
2014-07-01
... ACM from straight runs of piping and elbows and other connections with the following specifications... or other device used to prevent collapse of bag during removal shall run continually during the... pressure glove box systems. Negative pressure glove boxes may be used to remove ACM or PACM from pipe runs...
Code of Federal Regulations, 2013 CFR
2013-07-01
... ACM from straight runs of piping and elbows and other connections with the following specifications... or other device used to prevent collapse of bag during removal shall run continually during the... pressure glove box systems. Negative pressure glove boxes may be used to remove ACM or PACM from pipe runs...
Code of Federal Regulations, 2012 CFR
2012-07-01
... ACM from straight runs of piping and elbows and other connections with the following specifications... or other device used to prevent collapse of bag during removal shall run continually during the... pressure glove box systems. Negative pressure glove boxes may be used to remove ACM or PACM from pipe runs...
Code of Federal Regulations, 2011 CFR
2011-07-01
... ACM from straight runs of piping and elbows and other connections with the following specifications... or other device used to prevent collapse of bag during removal shall run continually during the... pressure glove box systems. Negative pressure glove boxes may be used to remove ACM or PACM from pipe runs...
18. DETAILED VIEW OF A GLOVE BOX DAMAGED IN A ...
18. DETAILED VIEW OF A GLOVE BOX DAMAGED IN A FIRE THAT OCCURRED ON MAY 11, 1969. THE FIRE OCCURRED FROM THE SPONTANEOUS IGNITION OF A BRIQUETTE OF SCRAP PLUTONIUM ALLOY METAL. (5/18/69) - Rocky Flats Plant, Plutonium Fabrication, Central section of Plant, Golden, Jefferson County, CO
Synthesis of Bis(1,2-Dimethylimidazole)Copper(I)Hexafluorophosphate: An Experiment Using a Glove Box
ERIC Educational Resources Information Center
Niewahner, J. H.; Walters, Keith A.
2007-01-01
A detailed description of the synthesis of bis(1,2-dimethylimidazole)copper(I) hexafluorophosphate by using techniques in a glove box is presented. The results shows that the synthesis of the copper complex has a distinct color change indicating by-product oxidation by oxygen.
8. VIEW OF GLOVE BOXES USED IN THE ANION EXCHANGE ...
8. VIEW OF GLOVE BOXES USED IN THE ANION EXCHANGE PROCESS. THE ANION EXCHANGE PROCESS PURIFIED AND CONCENTRATED PLUTONIUM-BEARING NITRIC ACID SOLUTIONS TO MAKE THEM ACCEPTABLE AS FEED FOR CONVERSION TO METAL. (6/20/60) - Rocky Flats Plant, Plutonium Recovery & Fabrication Facility, North-central section of plant, Golden, Jefferson County, CO
2. VIEW OF THE GLOVE BOX WHERE, ON SEPTEMBER 11, ...
2. VIEW OF THE GLOVE BOX WHERE, ON SEPTEMBER 11, 1957, A FIRE STARTED. THE FIRE SPREAD TO THE REST OF THE BUILDING, RESULTING IN THE TRANSFER OF PLUTONIUM FOUNDRY, FABRICATION, AND ASSEMBLY OPERATIONS TO BUILDING 776/777. (9/16/57) - Rocky Flats Plant, Plutonium Recovery & Fabrication Facility, North-central section of plant, Golden, Jefferson County, CO
Time cycle analysis and simulation of material flow in MOX process layout
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakraborty, S.; Saraswat, A.; Danny, K.M.
The (U,Pu)O{sub 2} MOX fuel is the driver fuel for the upcoming PFBR (Prototype Fast Breeder Reactor). The fuel has around 30% PuO{sub 2}. The presence of high percentages of reprocessed PuO{sub 2} necessitates the design of optimized fuel fabrication process line which will address both production need as well as meet regulatory norms regarding radiological safety criteria. The powder pellet route has highly unbalanced time cycle. This difficulty can be overcome by optimizing process layout in terms of equipment redundancy and scheduling of input powder batches. Different schemes are tested before implementing in the process line with the helpmore » of a software. This software simulates the material movement through the optimized process layout. The different material processing schemes have been devised and validity of the schemes are tested with the software. Schemes in which production batches are meeting at any glove box location are considered invalid. A valid scheme ensures adequate spacing between the production batches and at the same time it meets the production target. This software can be further improved by accurately calculating material movement time through glove box train. One important factor is considering material handling time with automation systems in place.« less
Extra-Vehicular Activity (EVA) glove evaluation test protocol
NASA Technical Reports Server (NTRS)
Hinman-Sweeney, E. M.
1994-01-01
One of the most critical components of a space suit is the gloves, yet gloves have traditionally presented significant design challenges. With continued efforts at glove development, a method for evaluating glove performance is needed. This paper presents a pressure-glove evaluation protocol. A description of this evaluation protocol, and its development is provided. The protocol allows comparison of one glove design to another, or any one design to bare-handed performance. Gloves for higher pressure suits may be evaluated at current and future design pressures to drive out differences in performance due to pressure effects. Using this protocol, gloves may be evaluated during design to drive out design problems and determine areas for improvement, or fully mature designs may be evaluated with respect to mission requirements. Several different test configurations are presented to handle these cases. This protocol was run on a prototype glove. The prototype was evaluated at two operating pressures and in the unpressurized state, with results compared to bare-handed performance. Results and analysis from this test series are provided, as is a description of the configuration used for this test.
Next Generation Life Support: High Performance EVA Glove
NASA Technical Reports Server (NTRS)
Walsh, Sarah K.
2015-01-01
The objectives of the High Performance EVA Glove task are to develop advanced EVA gloves for future human space exploration missions and generate corresponding standards by which progress may be quantitatively assessed. New technologies and manufacturing techniques will be incorporated into the new gloves to address finger and hand mobility, injury reduction and durability in nonpristine environments. Three prototypes will be developed, each focusing on different technological advances. A robotic assist glove will integrate a powered grasping system into the current EVA glove design to reduce astronaut hand fatigue and hand injuries. A mechanical counter pressure (MCP) glove will be developed to further explore the potential of MCP technology and assess its capability for countering the effects of vacuum or low pressure environments on the body by using compression fabrics or materials to apply the necessary pressure. A gas pressurized glove, incorporating new technologies, will be the most flight-like of the three prototypes. Advancements include the development and integration of aerogel insulation, damage sensing components, dust-repellant coatings, and dust tolerant bearings.
NASA Technical Reports Server (NTRS)
Cadogan, Dave; Lingo, Bob
1996-01-01
In July of 1996, ILC Dover was awarded Phase 1 of a contract for NASA to develop a prototype Power Assisted Space Suit glove to enhance the performance of astronauts during Extra-Vehicular Activity (EVA). This report summarizes the work performed to date on Phase 1, and details the work to be conducted on Phase 2 of the program. Phase 1 of the program consisted of research and review of related technical sources, concept brainstorming, baseline design development, modeling and analysis, component mock-up testing, and test data analysis. ILC worked in conjunction with the University of Maryland's Space Systems Laboratory (SSL) to develop the power assisted glove. Phase 2 activities will focus on the design maturation and the manufacture of a working prototype system. The prototype will be tested and evaluated in conjunction with existing space suit glove technology to determine the performance enhancement anticipated with the implementation of the power assisted joint technology in space suit gloves.
Boxing fatalities in relation to rule changes in Japan: secondary data analysis.
Teramoto, Masaru; Cross, Chad L; Cushman, Daniel M; Willick, Stuart E
2018-01-18
To examine whether changing weigh-in from the same day of the match to the day before the match and prohibiting 6-oz gloves are associated with fatalities in boxing matches sanctioned by the Japan Boxing Commission (JBC). We analyzed the rates of boxing fatalities before and after the two rule changes above via secondary analysis of data. Demographics and boxing records of deceased boxers were examined using descriptive statistics, exact binomial test the Mann-Whitney-Wilcoxon test and Fisher's exact tests. As of this study, a total of 38 boxers (23.9 ± 3.3 years of age) reportedly died due to injuries sustained in JBC-sanctioned boxing matches since 1952. Changing weigh-in to the day before the match or prohibiting 6-oz gloves was not significantly associated with the rates of boxing fatalities 5 years and 10 years before and after the rule changes (p > 0.05). Deceased boxers after these rule changes were significantly older, completed significantly more rounds in the final match, and were significantly less likely to lose the previous match (prior to the final match) and to do so by knockouts (p < 0.05). Changing weigh-in to the day before the match and prohibiting 6-oz gloves may not result in reducing boxing fatalities.
Durable Tactile Glove for Human or Robot Hand
NASA Technical Reports Server (NTRS)
Butzer, Melissa; Diftler, Myron A.; Huber, Eric
2010-01-01
A glove containing force sensors has been built as a prototype of tactile sensor arrays to be worn on human hands and anthropomorphic robot hands. The force sensors of this glove are mounted inside, in protective pockets; as a result of this and other design features, the present glove is more durable than earlier models.
Dismantling of the PETRA glove box: tritium contamination and inventory assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, R.
2015-03-15
The PETRA facility is the first installation in which experiments with tritium were carried out at the Tritium Laboratory Karlsruhe. After completion of two main experimental programs, the decommissioning of PETRA was initiated with the aim to reuse the glove box and its main still valuable components. A decommissioning plan was engaged to: -) identify the source of tritium release in the glove box, -) clarify the status of the main components, -) assess residual tritium inventories, and -) de-tritiate the components to be disposed of as waste. Several analytical techniques - calorimetry on small solid samples, wipe test followedmore » by liquid scintillation counting for surface contamination assessment, gas chromatography on gaseous samples - were deployed and cross-checked to assess the remaining tritium inventories and initiate the decommissioning process. The methodology and the main outcomes of the numerous different tritium measurements are presented and discussed. (authors)« less
3. VIEW OF CHAINVEYOR. AN ENCLOSED CHAIN CONVEYOR CONNECTED GLOVE ...
3. VIEW OF CHAINVEYOR. AN ENCLOSED CHAIN CONVEYOR CONNECTED GLOVE BOXES WITHIN AND BETWEEN MODULAR WORK AREAS. LEADED GLOVES WERE AFFIXED TO PORTS ALONG THE CHAINVEYOR PATHWAY TO ALLOW OPERATOR ACCESS. (1/25/93) - Rocky Flats Plant, Plutonium Manufacturing Facility, North-central section of Plant, just south of Building 776/777, Golden, Jefferson County, CO
2009-11-19
CAPE CANAVERAL, Fla. – This newly designed glove is one of the entries in the 2009 Astronaut Glove Challenge, part of NASA’s Centennial Challenges Program, at the Astronaut Hall of Fame near NASA’s Kennedy Space Center in Florida. The nationwide competition focused on developing improved pressure suit gloves for astronauts to use while working in space. During the challenge, inventors tested the gloves to measure dexterity and strength during operation in a glove box which simulates the vacuum of space. Centennial Challenges is NASA’s program of technology prizes for the citizen-inventor. The winning prize for the Glove Challenge is $250,000 provided by the Centennial Challenges Program. Photo credit: NASA/Kim Shiflett
The development of a test methodology for the evaluation of EVA gloves
NASA Technical Reports Server (NTRS)
O'Hara, John M.; Cleland, John; Winfield, Dan
1988-01-01
This paper describes the development of a standardized set of tests designed to assess EVA-gloved hand capabilities in six measurement domains: range of motion, strength, tactile perception, dexterity, fatigue, and comfort. Based upon an assessment of general human-hand functioning and EVA task requirements, several tests within each measurement domain were developed to provide a comprehensive evaluation. All tests were designed to be conducted in a glove box with the bare hand as a baseline and the EVA glove at operating pressure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oka, Jude M.
Present day glovebox gloves at Los Alamos National Laboratory (LANL) are underdeveloped and ergonomically inaccurate. This problem results in numerous sprain and strain injuries every year for employees who perform glovebox work. In addition to injuries, using the current glovebox glove design also contributes to breaches and contamination. The current glove used today at LANL has several problems: (1) The length of the fingers is incorrect, (2) the web spacing between the fingers is nonexistent, (3) the angles between each digit on the finger are incorrect, (4) the thumb is placed inaccurately, and (5) the length of the hand ismore » incorrect. These problems present a need to correct the current glove design to decrease the risk of injuries, breaches, and contamination. Anthropometrics were researched to help find the best range of hand measurements to fix the current glove design. Anthropometrics is the measure of the human physical variation. Anthropometrics for this study were gathered from the American National Survey (ANSUR) data that was conducted by the U.S Army in 1988. The current glovebox glove uses anthropometrics from the 95th to 105th percentile range which is too large so the new gloves are going to implement data from a smaller range of percentile groups. The 105th percentile range represents measurements that exceed the human population but are needed to fit certain circumstance such as wearing several under gloves within the glovebox gloves. Anthropometrics used in this study include: 105th percentile measurements for joint circumference which was unchanged because the room for under gloves plus ease of hand insertion and extraction is needed, 80th percentile measurements for crotch length to allow workers to reach the web spacing in the glove, 20th percentile measurements for finger length to allow workers to reach the end of the glove, standard 10.5cm hand breadth to allow more room to accommodate under gloves, 45 degrees abduction angle for the thumb for better positioning, 45 degrees extension angle for the thumb for better positioning, and various angles for the other fingers to allow a more relaxed and natural fit. 3D modeling was used to implement the anthropometric data listed above onto an existing scanned solid model of a human hand. SolidWorks 2010 3-D modeling package was utilized to manipulate the hand model to represent the anthropometric data researched. The anthropometrics and modifications were reviewed by the University of New Mexico Department of Orthopedics hand surgeons. After all modifications and reviews were completed the model was printed out using stereolithography. The printed out model of the hand was used as a mold to create a prototype glovebox glove. The new mold was taken to Piercan USA to produce a 20mil Polyurethane/Hypalon glovebox glove. The Minnesota Dexterity test and Purdue Pegboard test were used to measure the dexterity of the prototype glovebox glove against a current 15 mil Hypalon LANL glovebox glove. Using the data from the tests a student t test was used to determine if there was a significant difference between the current hypalon glove results and the new prototype glove results. With a 95% confidence level the prototype showed to have a significantly lower mean difference from the current hypalon glovebox glove with the Minnesota Dexterity test. With a 95% confidence level the prototype showed to have a significantly higher mean difference from the current hypalon glovebox glove with the Purdue Pegboard test. A p value method was also performed to confirm the results of the student t test. A survey was also given to glovebox workers to determine if they preferred the new design. The best reaction from glovebox workers was the new thumb position, 73.2% of the sample population agreed with the new thumb position. Developing a new glovebox glove will improve the ergonomics of the hand for work performed, decrease exposure time, decreasing risk of breaching, increasing productivity, reducing injuries, and improving work performance. In the future the new glovebox glove can also be implemented in other research fields such as: pharmaceutical research and development, semiconducting industry, biohazard industry, and other laboratories conducting nuclear research and development.« less
USMP-4 MGBX, Chawla and Kregel work with glovebox
1998-01-05
STS087-332-010 (19 November – 5 December 1997) --- Astronaut Kevin R. Kregel doesn't bother to "break" for coffee as he enjoys a serving while sharing work at the Space Shuttle Columbia's microgravity glove box with astronaut Kalpana Chawla. The glove box's (right edge of frame) proximity to the galley (partially obscured behind the mission commander) makes the time economy measure an easy task for the three-time space veteran. Chawla, mission specialist, is making her initial space flight.
2009-11-19
CAPE CANAVERAL, Fla. – This newly designed glove, one of the entries in the 2009 Astronaut Glove Challenge, undergoes a joint force test the 2009 Astronaut Glove Challenge, part of NASA’s Centennial Challenges Program, at the Astronaut Hall of Fame near NASA’s Kennedy Space Center in Florida. The nationwide competition focused on developing improved pressure suit gloves for astronauts to use while working in space. During the challenge, inventors tested the gloves to measure dexterity and strength during operation in a glove box which simulates the vacuum of space. Centennial Challenges is NASA’s program of technology prizes for the citizen-inventor. The winning prize for the Glove Challenge is $250,000 provided by the Centennial Challenges Program. Photo credit: NASA/Kim Shiflett
Brown, Robert H; Taenkhum, Kanika; Buckley, Timothy J; Hamilton, Robert G
2004-08-01
Proactive medical institutions implement latex allergen avoidance to protect workers and patients with latex allergy and to prevent latex sensitization in these groups by creating latex-safe environments that include replacement of natural rubber latex examination and surgical gloves, especially those that are powdered, with synthetic alternatives. We have hypothesized that an apparent decreasing trend in new latex allergy cases in hospitals using only synthetic examination gloves but the occasional powdered latex surgical glove might result from constitutive differences in allergen content (particle size distribution and quantity) between powdered surgical gloves and examination gloves. Because aerodynamic particle size determines where inhaled airborne allergen deposits in the airway, the aim of this study was to investigate the differential particle size distribution of latex allergen released from powdered latex examination and surgical gloves. Powdered and nonpowdered latex examination and surgical gloves were processed to create an aerosol in a glove box equipped with air sampling equipment capable of total particle number and mass measurements. Air particulate generated in the glove box was collected on impactors with less than 2.5-microm, 2.5- to 10-microm, and greater than 10-microm particle size limits (4 L/min for 4 hours). All filters were extracted, and latex allergen was quantified by using a latex-CAP inhibition assay with a human IgE anti-latex serum pool. Latex aeroallergen on powdered sterile surgical gloves resided primarily on particles greater than 10 microm in size (P <.006). In contrast, powdered examination gloves released the highest total latex aeroallergen content, with 68% of the particles sized in the respirable 2.5- to 10-microm range and carrying 56% of the airborne latex allergen. Significantly lower quantities and larger sizes of latex allergen-containing particles released from surgical gloves provides one potential explanation as to why an apparent decrease in new cases of latex allergy can occur in hospitals that successfully replace latex examination gloves with synthetic gloves but continue occasional use of powdered surgical gloves.
INTERIOR PHOTO OF THE REMOTE ANALYTICAL FACILITY OF SHIELDED GLOVE ...
INTERIOR PHOTO OF THE REMOTE ANALYTICAL FACILITY OF SHIELDED GLOVE BOXES IN OPERATING CORRIDOR (CPP-627). INL PHOTO NUMBER NRTS-55-1524. Unknown Photographer, 1955 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Laser etching of austenitic stainless steels for micro-structural evaluation
NASA Astrophysics Data System (ADS)
Baghra, Chetan; Kumar, Aniruddha; Sathe, D. B.; Bhatt, R. B.; Behere, P. G.; Afzal, Mohd
2015-06-01
Etching is a key step in metallography to reveal microstructure of polished specimen under an optical microscope. A conventional technique for producing micro-structural contrast is chemical etching. As an alternate, laser etching is investigated since it does not involve use of corrosive reagents and it can be carried out without any physical contact with sample. Laser induced etching technique will be beneficial especially in nuclear industry where materials, being radioactive in nature, are handled inside a glove box. In this paper, experimental results of pulsed Nd-YAG laser based etching of few austenitic stainless steels such as SS 304, SS 316 LN and SS alloy D9 which are chosen as structural material for fabrication of various components of upcoming Prototype Fast Breeder Reactor (PFBR) at Kalpakkam India were reported. Laser etching was done by irradiating samples using nanosecond pulsed Nd-YAG laser beam which was transported into glass paneled glove box using optics. Experiments were carried out to understand effect of laser beam parameters such as wavelength, fluence, pulse repetition rate and number of exposures required for etching of austenitic stainless steel samples. Laser etching of PFBR fuel tube and plug welded joint was also carried to evaluate base metal grain size, depth of fusion at welded joint and heat affected zone in the base metal. Experimental results demonstrated that pulsed Nd-YAG laser etching is a fast and effortless technique which can be effectively employed for non-contact remote etching of austenitic stainless steels for micro-structural evaluation.
NASA Technical Reports Server (NTRS)
McFarland, Shane
2016-01-01
Injuries to the hands are common among astronauts who train for extravehicular activity. When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of NASA's Lifetime Surveillance of Astronaut Health's injury database reveals that 76 percent of astronaut hand and arm injuries from training between 1993 and 2010 occurred either to the fingernail, finger crotch, metacarpophalangeal joint, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure forces acting on the fingers and hand within pressurized gloves and other variables such as skin temperature, humidity, and fingernail strain of a NASA crewmember during typical NBL (Neutral Buoyancy Laboratory) training activity. During the 5-hour exercise, the crewmember seemed to exhibit very large forces on some fingers, resulting in higher strain than seen in previous glove-box testing. In addition, vital information was collected on the glove cavity environment with respect to temperature and humidity. All of this information gathered during testing will be carried forward into future testing, potentially in glove-box- or 1G- (1 gravitational force) or NBL-suited environments, to better characterize and understand the possible causes of hand injury amongst NASA crew.
Cross Contamination: Are Hospital Gloves Reservoirs for Nosocomial Infections?
Moran, Vicki; Heuertz, Rita
2017-01-01
Use of disposable nonsterile gloves in the hospital setting is second only to proper hand washing in reducing contamination during patient contact. Because proper handwashing is not consistently practiced, added emphasis on glove use is warranted. There is a growing body of evidence that glove boxes and dispensers available to healthcare workers are contaminated by daily exposure to environmental organisms. This finding, in conjunction with new and emerging antibiotic-resistant bacteria, poses a threat to patients and healthcare workers alike. A newly designed glove dispenser may reduce contamination of disposable gloves. The authors investigated contamination of nonsterile examination gloves in an Emergency Department setting according to the type of dispenser used to access gloves. A statistically significant difference existed between the number of bacterial colonies and the type of dispenser: the downward-facing glove dispenser had a lower number of bacteria on the gloves. There was no statistically significant difference in the number of gloves contaminated between the two types of glove dispensers. The study demonstrated that contamination of disposable gloves existed. Additional research using a larger sample size would validate a difference in the contamination of disposable gloves using outward or downward glove dispensers.
Dosage delivery of sensitive reagents enables glove-box-free synthesis
NASA Astrophysics Data System (ADS)
Sather, Aaron C.; Lee, Hong Geun; Colombe, James R.; Zhang, Anni; Buchwald, Stephen L.
2015-08-01
Contemporary organic chemists employ a broad range of catalytic and stoichiometric methods to construct molecules for applications in the material sciences, and as pharmaceuticals, agrochemicals, and sensors. The utility of a synthetic method may be greatly reduced if it relies on a glove box to enable the use of air- and moisture-sensitive reagents or catalysts. Furthermore, many synthetic chemistry laboratories have numerous containers of partially used reagents that have been spoiled by exposure to the ambient atmosphere. This is exceptionally wasteful from both an environmental and a cost perspective. Here we report an encapsulation method for stabilizing and storing air- and moisture-sensitive compounds. We demonstrate this approach in three contexts, by describing single-use capsules that contain all of the reagents (catalysts, ligands, and bases) necessary for the glove-box-free palladium-catalysed carbon-fluorine, carbon-nitrogen, and carbon-carbon bond-forming reactions. This strategy should reduce the number of error-prone, tedious and time-consuming weighing procedures required for such syntheses and should be applicable to a wide range of reagents, catalysts, and substrate combinations.
Zondervan, Daniel K; Friedman, Nizan; Chang, Enoch; Zhao, Xing; Augsburger, Renee; Reinkensmeyer, David J; Cramer, Steven C
2016-01-01
Individuals with chronic stroke have limited options for hand rehabilitation at home. Here, we sought to determine the feasibility and efficacy of home-based MusicGlove therapy. Seventeen participants with moderate hand impairment in the chronic phase of stroke were randomized to 3 wk of home-based exercise with either the MusicGlove or conventional tabletop exercises. The primary outcome measure was the change in the Box and Blocks test score from baseline to 1 mo posttreatment. Both groups significantly improved their Box and Blocks test score, but no significant difference was found between groups. The MusicGlove group did exhibit significantly greater improvements than the conventional exercise group in motor activity log quality of movement and amount of use scores 1 mo posttherapy (p = 0.007 and p = 0.04, respectively). Participants significantly increased their use of MusicGlove over time, completing 466 gripping movements per day on average at study end. MusicGlove therapy was not superior to conventional tabletop exercises for the primary end point but was nevertheless feasible and led to a significantly greater increase in self-reported functional use and quality of movement of the impaired hand than conventional home exercises. ClinicalTrials.gov; "Influence of Timing on Motor Learning"; NCT01769326; https://clinicaltrials.gov/ct2/show/NCT01769326.
Molybdenum-99 Isotope Production Preparation at Sandia National Laboratories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carson, S.D.; Longley, S.W.; McDonald, M.J.
`Q&c M. J. McDonald, S. D. Carson, S. W. Longley, E. J. Parma, M. E. Vern `~ I@ .,., Sandia National Laboratories*, P. .0. Box 5800, Albuquerque, NM, 8 W? 1$ tl?;:q `f. (3 . 8 /'~ Abstract This report was prepared as an account of work sponsored byanagency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, make any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its usemore » would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. loading on the Cintichem targets. These tests were designed to gain process knowledge prior to processing an irradiated target. The chemical separation tests were performed in a fime hood During cold testing, several tests were performed on individual components of the process to complete, a series of `hot' tests was designed to process irradiated targets. These were designed to optimize the process, identify problems prior to processing higher inventory targets, and to the shielded containment box (SCB). Table 1 is a summary of the tests performed prior to the Test Target Power Post irradiation Total inventory 99M0 inventory (kW)/ Irradiation decay (hrs) (TBq*) /decay (TBq)/decay Time (hrs) inventory (TBq) inventory(TBq) in the processing boxes as color comparisons. Product quality control testing was conducted for all the tests and the results were compared to The production process generates a high activity acidic liquid waste. Several waste stabilization processing box. The cement, in addition to stabilizing the waste, neutralized the waste resulting The processing hardware and fixtures were developed in parallel to the cold tests and tested in a that expected during processing. During processing, precautions will be taken to minimize the Island incident. The facility consisted of shielded glove boxes, unshielded glove box lines and the the facility for production operations; the glove box lines and shielded glove boxes, all the new configuration will have six windows, four extraction boxes and a waste packaging box on the shielding. The walls and windows of the processing boxes will have the equivalent 150 of the purification box will be considerably less than the processing boxes with dose being from only `gMo. The increased wall thickness will reduce the dose levels to boxes will have under the box transport systems to move material into and out of the boxes. prior to FDA requiring process validation and, consequently, had not pertlormed a process« less
NASA Technical Reports Server (NTRS)
Ohara, John M.; Briganti, Michael; Cleland, John; Winfield, Dan
1988-01-01
One of the major probelms faced in Extravehicular Activity (EVA) glove development has been the absence of concise and reliable methods to measure the effects of EVA gloves on human hand capabilities. This report describes the development of a standardized set of tests designed to assess EVA-gloved hand capabilities in six measurement domains: Range of Motion, Strength, Tactile Perception, Dexterity, Fatigue, and Comfort. Based on an assessment of general human hand functioning and EVA task requirements several tests within each measurement domain were developed to provide a comprehensive evaluation. All tests were designed to be conducted in a glove box with the bare hand as a baseline and the EVA glove at operating pressure. A test program was conducted to evaluate the tests using a representative EVA glove. Eleven test subjects participated in a repeated-measures design. The report presents the results of the tests in each capability domain.
A human factors evaluation of Extravehicular Activity gloves
NASA Technical Reports Server (NTRS)
O'Hara, John M.; Briganti, Michael; Cleland, John; Winfield, Dan
1989-01-01
One of the major problems faced in Extravehicular Activity (EVA) glove development has been the absence of concise and reliable methods to measure the effects of EVA gloves on human-hand capabilities. NASA has sponsored a program to develop a standardized set of tests designed to assess EVA-gloved hand capabilities in six performance domains: Range of Motion, Strength, Tactile Perception, Dexterity, Fatigue, and Comfort. Based upon an assessment of general human-hand functioning and EVA task requirements, several tests within each performance domain were developed to provide a comprehensive evaluation. All tests were designed to be conducted in a glove box with the bare hand, an EVA glove without pressure, an EVA glove at operation pressure. Thus, the differential effect on performance of the glove with and without pressure was tested. Bare hand performance was used to 'calibrate' the effects. Ten subjects participated in the test setup as a repeated-measures experimental design. The paper will report the results of the test program.
Development and Test of Robotically Assisted Extravehicular Activity Gloves
NASA Technical Reports Server (NTRS)
Rogers, Jonathan M.; Peters, Benjamin J.; Laske, Evan A.; McBryan, Emily R.
2017-01-01
Over the past two years, the High Performance EVA Glove (HPEG) project under NASA's Space Technology Mission Directorate (STMD) funded an effort to develop an electromechanically-assisted space suit glove. The project was a collaboration between the Johnson Space Center's Software, Robotics, and Simulation Division and the Crew and Thermal Systems division. The project sought to combine finger actuator technology developed for Robonaut 2 with the softgoods from the ILC Phase VI EVA glove. The Space Suit RoboGlove (SSRG) uses a system of three linear actuators to pull synthetic tendons attached to the glove's fingers to augment flexion of the user's fingers. To detect the user's inputs, the system utilizes a combination of string potentiometers along the back of the fingers and force sensitive resistors integrated into the fingertips of the glove cover layer. This paper discusses the development process from initial concepts through two major phases of prototypes, and the results of initial human testing. Initial work on the project focused on creating a functioning proof of concept, designing the softgoods integration, and demonstrating augmented grip strength with the actuators. The second year of the project focused on upgrading the actuators, sensors, and software with the overall goal of creating a system that moves with the user's fingers in order to reduce fatigue associated with the operation of a pressurized glove system. This paper also discusses considerations for a flight system based on this prototype development and address where further work is required to mature the technology.
New Approach in Filling of Fixed-Point Cells: Case Study of the Melting Point of Gallium
NASA Astrophysics Data System (ADS)
Bojkovski, J.; Hiti, M.; Batagelj, V.; Drnovšek, J.
2008-02-01
The typical way of constructing fixed-point cells is very well described in the literature. The crucible is loaded with shot, or any other shape of pure metal, inside an argon-filled glove box. Then, the crucible is carefully slid into a fused-silica tube that is closed at the top with an appropriate cap. After that, the cell is removed from the argon glove box and melted inside a furnace while under vacuum or filled with an inert gas like argon. Since the metal comes as shot, or in some other shape such as rods of various sizes, and takes more volume than the melted material, it is necessary to repeat the procedure until a sufficient amount of material is introduced into the crucible. With such a procedure, there is the possibility of introducing additional impurities into the pure metal with each cycle of melting the material and putting it back into the glove box to fill the cell. Our new approach includes the use of a special, so-called dry-box system, which is well known in chemistry. The atmosphere inside the dry box contains less than 20 ppm of water and less than 3 ppm of oxygen. Also, the size of the dry box allows it to contain a furnace for melting materials, not only for gallium but for higher-temperature materials as well. With such an approach, the cell and all its parts (pure metal, graphite, fused-silica tube, and cap) are constantly inside the controlled atmosphere, even while melting the material and filling the crucible. With such a method, the possibility of contaminating the cell during the filling process is minimized.
2009-11-19
CAPE CANAVERAL, Fla. – Alan Hayes, at microphone, chairman of Volanz Aerospace Inc., addresses the participants in the 2009 Astronaut Glove Challenge, part of NASA’s Centennial Challenges Program, at the Astronaut Hall of Fame near NASA’s Kennedy Space Center in Florida. Volanz Aerospace Inc., of Owings, Md., administers the competition at no cost to NASA. The nationwide competition focused on developing improved pressure suit gloves for astronauts to use while working in space. During the challenge, inventors tested the gloves to measure dexterity and strength during operation in a glove box which simulates the vacuum of space. Centennial Challenges is NASA’s program of technology prizes for the citizen-inventor. The winning prize for the Glove Challenge is $250,000 provided by the Centennial Challenges Program. Photo credit: NASA/Kim Shiflett
2009-11-19
CAPE CANAVERAL, Fla. – Paul Secor, left, of Secor Strategies LLC, addresses the participants in the 2009 Astronaut Glove Challenge, part of NASA’s Centennial Challenges Program, at the Astronaut Hall of Fame near NASA’s Kennedy Space Center in Florida. Secor Strategies LLC, of Titusville, Fla., is a sponsor of the event and provided local logistical services. The nationwide competition focused on developing improved pressure suit gloves for astronauts to use while working in space. During the challenge, inventors tested the gloves to measure dexterity and strength during operation in a glove box which simulates the vacuum of space. Centennial Challenges is NASA’s program of technology prizes for the citizen-inventor. The winning prize for the Glove Challenge is $250,000 provided by the Centennial Challenges Program. Photo credit: NASA/Kim Shiflett
Design options for improving protective gloves for industrial assembly work.
Dianat, Iman; Haslegrave, Christine M; Stedmon, Alex W
2014-07-01
The study investigated the effects of wearing two new designs of cotton glove on several hand performance capabilities and compared them against the effects of barehanded, single-layered and double cotton glove conditions when working with hand tools (screwdriver and pliers). The new glove designs were based on the findings of subjective hand discomfort assessments for this type of work and aimed to match the glove thickness to the localised pressure and sensitivity in different areas of the hand as well as to provide adequate dexterity for fine manipulative tasks. The results showed that the first prototype glove and the barehanded condition were comparable and provided better dexterity and higher handgrip strength than double thickness gloves. The results support the hypothesis that selective thickness in different areas of the hand could be applied by glove manufacturers to improve the glove design, so that it can protect the hands from the environment and at the same time allow optimal hand performance capabilities. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Friedman, Nizan; Chan, Vicky; Zondervan, Danny; Bachman, Mark; Reinkensmeyer, David J
2011-01-01
People with stroke typically must perform much of their hand exercise at home without professional assistance as soon as two weeks after the stroke. Without feedback and encouragement, individuals often lose motivation to practice using the affected hand, and this disuse contributes to further declines in hand function. We developed the MusicGlove as a way to facilitate and motivate at home practice of hand movement. This low-cost device uses music as an interactive and motivating medium to guide hand exercise and to quantitatively assess hand movement recovery. It requires the user to practice functional movements, including pincer grip, key-pinch grip, and finger-thumb opposition, by using those movements to play different musical notes, played along to songs displayed by an interactive computer game. We report here the design of the glove and the results of a single-session experiment with 10 participants with chronic stroke. We found that the glove is well suited for use by people with an impairment level quantified by a Box and Blocks score of at least around 7; that the glove can be used to obtain a measure of hand dexterity (% of notes hit) that correlates strongly with the Box and Blocks score; and that the incorporation of music into training significantly improved both objective measures of hand motor performance and self-ratings of motivation for training in the single session.
The Effects of Extravehicular Activity (EVA) Glove Pressure on Hand Strength
NASA Technical Reports Server (NTRS)
Rajulu, Sudhakar; Mesloh, Miranda; Thompson, Shelby; England, Scott; Benson, Liz
2009-01-01
With the new vision of space travel aimed at traveling back to the Moon and eventually to Mars, NASA is designing a new spacesuit glove. The purpose of this study was to baseline hand strength while wearing the current Extravehicular Activity (EVA) glove, the Phase VI. By varying the pressure in the glove, hand strength could be characterized as a function of spacesuit pressure. This finding is of extreme importance when evaluating missions that require varying suit pressures associated with different operations within NASA's current human spaceflight program, Constellation. This characterization fed directly into the derivation of requirements for the next EVA glove. This study captured three types of maximum hand strength: grip, lateral pinch, and pulp-2 pinch. All three strengths were measured under varying pressures and compared to a bare-hand condition. The resulting standardized data was reported as a percentage of the bare-hand strength. The first wave of tests was performed while the subjects, four female and four male, were wearing an Extravehicular Mobility Unit (EMU) suit supported by a suit stand. This portion of the test collected data from the barehand, suited unpressurized, and suited pressurized (4.3 psi) conditions. In addition, the effects of the Thermal Micrometeoroid Garment (TMG) on hand strength were examined, with the suited unpressurized and pressurized cases tested with and without a TMG. It was found that, when pressurized and with the TMG, the Phase VI glove reduced applied grip strength to a little more than half of the subject s bare-hand strength. The lateral pinch strength remained relatively constant while the pulp-2 pinch strength actually increased with pressure. The TMG was found to decrease maximum applied grip strength by an additional 10% for both pressurized and unpressurized cases, while the pinch strengths saw little to no change. In developing requirements based on human subjects, it is important to attempt to derive results that encompass the variation within the entire population. The current EMU does not accommodate humans at the extremes of the anthropometric spectrum. To account for this and to ensure that these requirements cover the population, another phase of testing will be conducted in a differential pressure glove box. This phase will focus on smaller females and very large males that do not have a properly fitted EMU suit. Instead, they would wear smaller or larger gloves and be tested in the glove box as a means to compare and contrast their strength capabilities against the EMU accommodated hand size subjects. The glove box s ability to change pressures easily will also allow for a wider range of glove pressures to be tested. Compared to the data collected on the subjects wearing the EMU suit, it is expected that there will be similar ratios to bare-hand. It is recommended that this topic be sent to the Physical Ergonomics Board for review.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alaniz, Ariana J.; Delgado, Luc R.; Werbick, Brett M.
The objective of this senior student project is to design and build a prototype construction of a machine that simultaneously provides the proper pressure and temperature parameters to sinter ceramic powders in-situ to create pellets of rather high densities of above 90% (theoretical). This ROHUP (Remote Operated Hot Uniaxial Press) device is designed specifically to fabricate advanced ceramic Tc-99 bearing waste forms and therefore radiological barriers have been included in the system. The HUP features electronic control and feedback systems to set and monitor pressure, load, and temperature parameters. This device operates wirelessly via portable computer using Bluetooth{sup R} technology.more » The HUP device is designed to fit in a standard atmosphere controlled glove box to further allow sintering under inert conditions (e.g. under Ar, He, N{sub 2}). This will further allow utilizing this HUP for other potential applications, including radioactive samples, novel ceramic waste forms, advanced oxide fuels, air-sensitive samples, metallic systems, advanced powder metallurgy, diffusion experiments and more. (authors)« less
2009-11-19
CAPE CANAVERAL, Fla. – At the Astronaut Hall of Fame near NASA’s Kennedy Space Center in Florida, participants in the 2009 Astronaut Glove Challenge, part of NASA’s Centennial Challenges Program, pose for a group portrait. In the center of the front row are the winners, Ted Southern of Brooklyn, N.Y., at left, and Peter Homer of Southwest Harbor, Maine. The nationwide competition focused on developing improved pressure suit gloves for astronauts to use while working in space. During the challenge, the gloves were submitted to burst tests, joint force tests and tests to measure their dexterity and strength during operation in a glove box which simulates the vacuum of space. Centennial Challenges is NASA’s program of technology prizes for the citizen-inventor. The winning prize for the Glove Challenge is $250,000 provided by the Centennial Challenges Program. Photo credit: NASA/Kim Shiflett
NASA Technical Reports Server (NTRS)
Walsh, Sarah; Barta, Daniel; Stephan, Ryan; Gaddis, Stephen
2015-01-01
The overall objective is to develop advanced gloves for extra vehicular activity (EVA) for future human space exploration missions and generate corresponding standards by which progress may be quantitatively assessed. The glove prototypes that result from the successful completion of this technology development activity will be delivered to NASA's Human Exploration Operations Mission Directorate (HEOMD) and ultimately to be included in an integrated test with the next generation spacesuit currently under development.
Christiansen, Robert M.; Mills, William C.
1992-01-01
The swipe transfer assembly is a mechanical assembly which is used in conjunction with glove boxes and other sealed containments. It is used to pass small samples into or out of glove boxes without an open breach of the containment, and includes a rotational cylinder inside a fixed cylinder, the inside cylinder being rotatable through an arc of approximately 240.degree. relative to the outer cylinder. An offset of 120.degree. from end to end allows only one port to be opened at a time. The assembly is made of stainless steel or aluminum and clear acrylic plastic to enable visual observation. The assembly allows transfer of swipes and smears from radiological and other specially controlled environments.
Benchmarking Evaluation Results for Prototype Extravehicular Activity Gloves
NASA Technical Reports Server (NTRS)
Aitchison, Lindsay; McFarland, Shane
2012-01-01
The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for unique mission scenarios outside the Space Shuttle and International Space Station (ISS) Program realm of experience. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Game-Changing Technology group provided start-up funding for the High Performance EVA Glove (HPEG) Project in the spring of 2012. The overarching goal of the HPEG Project is to develop a robust glove design that increases human performance during EVA and creates pathway for future implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability by 100%, and decreasing the potential of gloves to cause injury during use. The HPEG Project focused initial efforts on identifying potential new technologies and benchmarking the performance of current state of the art gloves to identify trends in design and fit leading to establish standards and metrics against which emerging technologies can be assessed at both the component and assembly levels. The first of the benchmarking tests evaluated the quantitative mobility performance and subjective fit of four prototype gloves developed by Flagsuit LLC, Final Frontier Designs, LLC Dover, and David Clark Company as compared to the Phase VI. All of the companies were asked to design and fabricate gloves to the same set of NASA provided hand measurements (which corresponded to a single size of Phase Vi glove) and focus their efforts on improving mobility in the metacarpal phalangeal and carpometacarpal joints. Four test subjects representing the design ]to hand anthropometry completed range of motion, grip/pinch strength, dexterity, and fit evaluations for each glove design in both the unpressurized and pressurized conditions. This paper provides a comparison of the test results along with a detailed description of hardware and test methodologies used.
Space suit glove design with advanced metacarpal phalangeal joints and robotic hand evaluation.
Southern, Theodore; Roberts, Dustyn P; Moiseev, Nikolay; Ross, Amy; Kim, Joo H
2013-06-01
One area of space suits that is ripe for innovation is the glove. Existing models allow for some fine motor control, but the power grip--the act of grasping a bar--is cumbersome due to high torque requirements at the knuckle or metacarpal phalangeal joint (MCP). This area in particular is also a major source of complaints of pain and injury as reported by astronauts. This paper explores a novel fabrication and patterning technique that allows for more freedom of movement and less pain at this crucial joint in the manned space suit glove. The improvements are evaluated through unmanned testing, manned testing while depressurized in a vacuum glove box, and pressurized testing with a robotic hand. MCP joint flex score improved from 6 to 6.75 (out of 10) in the final glove relative to the baseline glove, and torque required for flexion decreased an average of 17% across all fingers. Qualitative assessments during unpressurized and depressurized manned testing also indicated the final glove was more comfortable than the baseline glove. The quantitative results from both human subject questionnaires and robotic torque evaluation suggest that the final iteration of the glove design enables flexion at the MCP joint with less torque and more comfort than the baseline glove.
Spacesuit glove manufacturing enhancements through the use of advanced technologies
NASA Astrophysics Data System (ADS)
Cadogan, David; Bradley, David; Kosmo, Joseph
The sucess of astronauts performing extravehicular activity (EVA) on orbit is highly dependent upon the performance of their spacesuit gloves.A study has recently been conducted to advance the development and manufacture of spacesuit gloves. The process replaces the manual techniques of spacesuit glove manufacture by utilizing emerging technologies such as laser scanning, Computer Aided Design (CAD), computer generated two-dimensional patterns from three-dimensionl surfaces, rapid prototyping technology, and laser cutting of materials, to manufacture the new gloves. Results of the program indicate that the baseline process will not increase the cost of the gloves as compared to the existing styles, and in production, may reduce the cost of the gloves. perhaps the most important outcome of the Laserscan process is that greater accuracy and design control can be realized. Greater accuracy was achieved in the baseline anthropometric measurement and CAD data measurement which subsequently improved the design feature. This effectively enhances glove performance through better fit and comfort.
The impact performance of headguards for combat sports.
McIntosh, Andrew S; Patton, Declan A
2015-09-01
To assess the impact energy attenuation performance of a range of headguards for combat sports. Seven headguards worn during combat sport training or competition, including two Association Internationale de Boxe Amateur (AIBA)-approved boxing models, were tested using drop tests. An International Organization for Standardization (ISO) rigid headform was used with a 5.6 kg drop assembly mass. Tests were conducted against a flat rigid anvil both with and without a boxing glove section. The centre forehead and lateral headguard areas were tested. Peak headform acceleration was measured. Tests from a selection of drop heights and repeated tests on the same headguard were conducted. Headguard performance varied by test condition. For the 0.4 m rigid anvil tests, the best model headguard was the thickest producing an average peak headform acceleration over 5 tests of 48 g compared with 456 g for the worst model. The mean peak acceleration for the 0.4, 0.5 and 0.6 frontal and lateral rigid anvil impact tests was between 32% and 40% lower for the Top Ten boxing model compared with the Adidas boxing model. The headguard performance deterioration observed with repeat impact against the flat anvil was reduced for impacts against the glove section. The overall reduction in acceleration for the combination of glove and headguard in comparison to the headguard condition was in the range of 72-93% for 0.6 and 0.8 m drop tests. The impact tests show the benefits of performance testing in identifying differences between headguard models. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Minimizing Glovebox Glove Breaches, Part III: Deriving Service Lifetimes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cournoyer, M.E.; Wilson, K.V.; Maestas, M.M.
At the Los Alamos Plutonium Facility, various isotopes of plutonium along with other actinides are handled in a glove box environment. Weapons-grade plutonium consists mainly in Pu-239. Pu-238 is another isotope used for heat sources. The Pu-238 is more aggressive regarding gloves due to its higher alpha-emitting characteristic ({approx}300 times more active than Pu-239), which modifies the change-out intervals for gloves. Optimization of the change-out intervals for gloves is fundamental since Nuclear Materials Technology (NMT) Division generates approximately 4 m{sup 3}/yr of TRU waste from the disposal of glovebox gloves. To reduce the number of glovebox glove failures, the NMTmore » Division pro-actively investigates processes and procedures that minimize glove failures. Aging studies have been conducted that correlate changes in mechanical (physical) properties with degradation chemistry. This present work derives glovebox glove change intervals based on mechanical data of thermally aged Hypalon{sup R}, and Butasol{sup R} glove samples. Information from this study represent an important baseline in gauging the acceptable standards for polymeric gloves used in a laboratory glovebox environment and will be used later to account for possible presence of dose-rate or synergistic effects in 'combined-environment'. In addition, excursions of contaminants into the operator's breathing zone and excess exposure to the radiological sources associated with unplanned breaches in the glovebox are reduced. (authors)« less
Design of rehabilitation robot hand for fingers CPM training
NASA Astrophysics Data System (ADS)
Zhou, Hongfu; Chan, T. W.; Tong, K. Y.; Kwong, K. K.; Yao, Xifan
2008-10-01
This paper presents a low-cost prototype for rehabilitation robot aide patient do hands CPM (continuous passive motion) training. The design of the prototype is based on the principle of Rutgers Master II glove, but it is better in performance for more improvement made. In the design, it uses linear motors to replace pneumatic actuators to make the product more portable and mobile. It increases finger training range to 180 degree for the full range training of hand finger holding and extension. Also the prototype can not only be wearing on palm and fore arm do training for face to face with finger move together, but also be put in the opposite hand glove wear direction for hand rehabilitation training. During the research, Solidworks is used as the tool for mechanical design and movement simulation. It proved through experiment that the prototype made in the research is appropriate for hand do CPM training.
Unusual presentation of herpes simplex virus infection in a boxer: 'Boxing glove herpes'.
García-García, Begoña; Galache-Osuna, Cristina; Coto-Segura, Pablo; Suárez-Casado, Héctor; Mallo-García, Susana; Jiménez, Jorge Santos-Juanes
2013-02-01
Herein, we describe a patient with lesions of cutaneous herpes simplex virus 1 (HSV-1) infection over the knuckles of both hands in the context of an outbreak among boxers. Interestingly, the infection had an unusually long duration (4 weeks), and was not acquired directly through skin-to-skin contact, as it usually does among athletes (herpes gladiatorum). In our case, transmission was acquired through the use of shared boxing gloves contaminated by HSV-1. To the best of our knowledge, herpes gladiatorum, or wrestler's herpes, has not been described previously in boxers and infection over the knuckles is not commonly reported. © 2011 The Authors. Australasian Journal of Dermatology © 2011 The Australasian College of Dermatologists.
Development of a test protocol for evaluating EVA glove performance
NASA Technical Reports Server (NTRS)
Hinman, Elaine M.
1992-01-01
Testing gloved hand performance involves work from several disciplines. Evaluations performed in the course of reenabling a disabled hand, designing a robotic end effector or master controller, or hard-suit design have all yielded relevant information, and, in most cases, produced performance test methods. Most times, these test methods have been primarily oriented toward their parent discipline. For space operations, a comparative test which would provide a way to quantify pressure glove and end effector performance would be useful in dividing tasks between humans and robots. Such a test would have to rely heavily on sensored measurement, as opposed to questionnaires, to produce relevant data. However, at some point human preference would have to be taken into account. This paper presents a methodology for evaluating gloved hand performance which attempts to respond to these issues. Glove testing of a prototype glove design using this method is described.
20. VIEW OF THE INTERIOR OF THE ADVANCED SIZE REDUCTION ...
20. VIEW OF THE INTERIOR OF THE ADVANCED SIZE REDUCTION FACILITY USED TO CUT PLUTONIUM CONTAMINATED GLOVE BOXES AND MISCELLANEOUS LARGE EQUIPMENT DOWN TO AN EASILY PACKAGED SIZE FOR DISPOSAL. ROUTINE OPERATIONS WERE PERFORMED REMOTELY, USING HOISTS, MANIPULATOR ARMS, AND GLOVE PORTS TO REDUCE BOTH INTENSITY AND TIME OF RADIATION EXPOSURE TO THE OPERATOR. (11/6/86) - Rocky Flats Plant, Plutonium Fabrication, Central section of Plant, Golden, Jefferson County, CO
Baqi, Younis; Müller, Christa E
2010-05-01
This protocol describes the efficient, generally applicable Ullmann coupling reaction of bromaminic acid with alkyl- or aryl-amines in phosphate buffer under microwave irradiation using elemental copper as a catalyst. The reaction leads to a number of biologically active compounds. As a prototypical example, the synthesis of a new, potent antagonist of human platelet P2Y(12) receptors, which has potential as an antithrombotic drug, is described in detail. The optimized protocol includes a description of an appropriate reaction setup, thin layer chromatography for monitoring the reaction and a procedure for the isolation, purification and characterization of the anticipated product. The reaction is performed without the use of a glove box and there is no requirement for an inert atmosphere. The reaction typically proceeds within 2-30 min, the protocol, including workup, generally takes 1-3 h to complete.
NASA's Student Glovebox: An Inquiry-Based Technology Educator's Guide.
ERIC Educational Resources Information Center
Rosenberg, Carla B.; Rogers, Melissa J. B.
This inquiry-based activity discusses the development of a glovebox like those used on the International Space Station and Space Shuttle. A glovebox is a box used for experimentation in which the user inserts hands into gloved access holes in order to work in the box. Activities concerning the study of liquid droplets are included to give students…
2009-11-19
CAPE CANAVERAL, Fla. - At the Astronaut Hall of Fame near NASA’s Kennedy Space Center in Florida, the winners of the 2009 Astronaut Glove Challenge, part of NASA’s Centennial Challenges Program, pose for a group photograph with their friends, family and the event organizers. From left are Caroline Homer and her father, Peter Homer, winner of the $250,000 first prize; Alan Hayes, chairman of Volanz Aerospace Inc.; Andy Petro, manager of NASA Centennial Challenges; Ted Southern, winner of the $100,000 second prize; his friend and glove tester Amy Miller; and Paul Secor, Secor Strategies LLC. The nationwide competition focused on developing improved pressure suit gloves for astronauts to use while working in space. During the challenge, the gloves were submitted to burst tests, joint force tests and tests to measure their dexterity and strength during operation in a glove box which simulates the vacuum of space. Centennial Challenges is NASA’s program of technology prizes for the citizen-inventor. The winning prize for the Glove Challenge is $250,000 provided by the Centennial Challenges Program. Photo credit: NASA/Kim Shiflett
Use of Video Analysis System for Working Posture Evaluations
NASA Technical Reports Server (NTRS)
McKay, Timothy D.; Whitmore, Mihriban
1994-01-01
In a work environment, it is important to identify and quantify the relationship among work activities, working posture, and workplace design. Working posture may impact the physical comfort and well-being of individuals, as well as performance. The Posture Video Analysis Tool (PVAT) is an interactive menu and button driven software prototype written in Supercard (trademark). Human Factors analysts are provided with a predefined set of options typically associated with postural assessments and human performance issues. Once options have been selected, the program is used to evaluate working posture and dynamic tasks from video footage. PVAT has been used to evaluate postures from Orbiter missions, as well as from experimental testing of prototype glove box designs. PVAT can be used for video analysis in a number of industries, with little or no modification. It can contribute to various aspects of workplace design such as training, task allocations, procedural analyses, and hardware usability evaluations. The major advantage of the video analysis approach is the ability to gather data, non-intrusively, in restricted-access environments, such as emergency and operation rooms, contaminated areas, and control rooms. Video analysis also provides the opportunity to conduct preliminary evaluations of existing work areas.
Integrity of Disposable Nitrile Exam Gloves Exposed to Simulated Movement
Phalen, Robert N.; Wong, Weng Kee
2011-01-01
Every year, millions of health care, first responder, and industry workers are exposed to chemical and biological hazards. Disposable nitrile gloves are a common choice as both a chemical and physical barrier to these hazards, especially as an alternative to natural latex gloves. However, glove selection is complicated by the availability of several types or formulations of nitrile gloves, such as low-modulus, medical-grade, low-filler, and cleanroom products. This study evaluated the influence of simulated movement on the physical integrity (i.e., holes) of different nitrile exam glove brands and types. Thirty glove products were evaluated out-of-box and after exposure to simulated whole-glove movement for 2 hr. In lieu of the traditional 1-L water-leak test, a modified water-leak test, standardized to detect a 0.15 ± 0.05 mm hole in different regions of the glove, was developed. A specialized air inflation method simulated bidirectional stretching and whole-glove movement. A worst-case scenario with maximum stretching was evaluated. On average, movement did not have a significant effect on glove integrity (chi-square; p=0.068). The average effect was less than 1% between no movement (1.5%) and movement (2.1%) exposures. However, there was significant variability in glove integrity between different glove types (p ≤ 0.05). Cleanroom gloves, on average, had the highest percentage of leaks, and 50% failed the water-leak test. Low-modulus and medical-grade gloves had the lowest percentages of leaks, and no products failed the water-leak test. Variability in polymer formulation was suspected to account for the observed discrepancies, as well as the inability of the traditional 1-L water-leak test to detect holes in finger/thumb regions. Unexpectedly, greater than 80% of the glove defects were observed in the finger and thumb regions. It is recommended that existing water-leak tests be re-evaluated and standardized to account for product variability. PMID:21476169
Harte, Daniel; Paterson, Abby
2017-10-28
Case series. Hand injuries are the most common injury observed in hurling although compliance in wearing protective gloves is reportedly low. To devise a glove that offers comfort, protection and freedom of movement, using the bespoke capabilities of 3-dimensional (3D) printing. Each player's "catching" hand was imaged using a 3D scanner to produce a bespoke glove that they later trialed and provided feedback. Nine players provided feedback. On average, the players favorably rated the glove for the protection offered. The average response on comfort was poor, and no players reported that glove aided performance during play. This feasibility study explores the versatility of 3D printing as a potential avenue to improve player compliance in wearing protective sportswear. Feedback will help refine glove design for future prototypes. Hurling is the primary focus in this study, but knowledge gains should be transferable to other sports that have a high incidence of hand injury. 4. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Development of a Pre-Prototype Power Assisted Glove End Effector for Extravehicular Activity
NASA Technical Reports Server (NTRS)
1986-01-01
The purpose of this program was to develop an EVA power tool which is capable of performing a variety of functions while at the same time increasing the EVA crewmember's effectiveness by reducing hand fatigue associated with gripping tools through a pressurized EMU glove. The Power Assisted Glove End Effector (PAGE) preprototype hardware met or exceeded all of its technical requirements and has incorporated acoustic feedback to allow the EVA crewmember to monitor motor loading and speed. If this tool is to be developed for flight use, several issues need to be addressed. These issues are listed.
Handling and analysis of ices in cryostats and glove boxes in view of cometary samples
NASA Technical Reports Server (NTRS)
Roessler, K.; Eich, G.; Heyl, M.; Kochan, H.; Oehler, A.; Patnaik, A.; Schlosser, W.; Schulz, R.
1989-01-01
Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples.
NASA Technical Reports Server (NTRS)
Adams, Richard J.; Olowin, Aaron; Krepkovich, Eileen; Hannaford, Blake; Lindsay, Jack I. C.; Homer, Peter; Patrie, James T.; Sands, O. Scott
2013-01-01
The Glove-Enabled Computer Operations (GECO) system enables an extravehicular activity (EVA) glove to be dual-purposed as a human-computer interface device. This paper describes the design and human participant testing of a right-handed GECO glove in a pressurized glove box. As part of an investigation into the usability of the GECO system for EVA data entry, twenty participants were asked to complete activities including (1) a Simon Says Games in which they attempted to duplicate random sequences of targeted finger strikes and (2) a Text Entry activity in which they used the GECO glove to enter target phrases in two different virtual keyboard modes. In a within-subjects design, both activities were performed both with and without vibrotactile feedback. Participants' mean accuracies in correctly generating finger strikes with the pressurized glove were surprisingly high, both with and without the benefit of tactile feedback. Five of the subjects achieved mean accuracies exceeding 99% in both conditions. In Text Entry, tactile feedback provided a statistically significant performance benefit, quantified by characters entered per minute, as well as reduction in error rate. Secondary analyses of responses to a NASA Task Loader Index (TLX) subjective workload assessments reveal a benefit for tactile feedback in GECO glove use for data entry. This first-ever investigation of employment of a pressurized EVA glove for human-computer interface opens up a wide range of future applications, including text "chat" communications, manipulation of procedures/checklists, cataloguing/annotating images, scientific note taking, human-robot interaction, and control of suit and/or other EVA systems.
NASA Technical Reports Server (NTRS)
Adams, Richard J.; Olowin, Aaron; Krepkovich, Eileen; Hannaford, Blake; Lindsay, Jack I. C.; Homer, Peter; Patrie, James T.; Sands, O. Scott
2013-01-01
The Glove-Enabled Computer Operations (GECO) system enables an extravehicular activity (EVA) glove to be dual-purposed as a human-computer interface device. This paper describes the design and human participant testing of a right-handed GECO glove in a pressurized glove box. As part of an investigation into the usability of the GECO system for EVA data entry, twenty participants were asked to complete activities including (1) a Simon Says Games in which they attempted to duplicate random sequences of targeted finger strikes and (2) a Text Entry activity in which they used the GECO glove to enter target phrases in two different virtual keyboard modes. In a within-subjects design, both activities were performed both with and without vibrotactile feedback. Participants mean accuracies in correctly generating finger strikes with the pressurized glove were surprisingly high, both with and without the benefit of tactile feedback. Five of the subjects achieved mean accuracies exceeding 99 in both conditions. In Text Entry, tactile feedback provided a statistically significant performance benefit, quantified by characters entered per minute, as well as reduction in error rate. Secondary analyses of responses to a NASA Task Loader Index (TLX) subjective workload assessments reveal a benefit for tactile feedback in GECO glove use for data entry. This first-ever investigation of employment of a pressurized EVA glove for human-computer interface opens up a wide range of future applications, including text chat communications, manipulation of procedureschecklists, cataloguingannotating images, scientific note taking, human-robot interaction, and control of suit andor other EVA systems.
NASA Astrophysics Data System (ADS)
Dolez, Patricia; Vinches, Ludwig; Wilkinson, Kevin; Plamondon, Philippe; Vu-Khanh, Toan
2011-07-01
Nanoparticle manufacture and use are in full expansion. The associated risks of occupational exposure raise large concerns due to their potential toxicity. Even if they stand as a last resort in the traditional occupational Health & Safety (H&S) risk management strategy, personal protective equipment (PPE) against nanoparticles are an absolute need in the context of precautionary principle advocated by H&S organizations worldwide. However no standard test method is currently available for evaluating the efficiency of PPE against nanoparticles, in particular in the case of gloves. A project is thus underway to develop a test method for measuring nanoparticle penetration through protective gloves in conditions simulating glove-nanoparticle occupational interaction. The test setup includes an exposure and a sampling chamber separated by a circular glove sample. A system of cylinders is used to deform the sample while it is exposed to nanoparticles. The whole system is enclosed in a glove box to ensure the operator safety during assembly, dismounting and clean-up operations as well as during the tests. Appropriate nanoparticle detection techniques were also identified. Results are reported here for commercial 15nm TiO2 nanoparticles - powder and colloidal solutions in 1,2-propanediol, ethylene glycol and water - and four types of protective gloves: disposable nitrile and latex as well as unsupported neoprene and butyl rubber gloves. They show that mechanical deformations and contact with colloidal solution liquid carriers may affect glove materials. Preliminary results obtained with TiO2 powder indicate a possible penetration of nanoparticles through gloves following mechanical deformations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cordaro, J.; Shull, D.; Farrar, M.
Radiation monitoring in nuclear facilities is essential to safe operation of the equipment as well as protecting personnel. In specific, typical air monitoring of radioactive gases or particulate involves complex systems of valves, pumps, piping and electronics. The challenge is to measure a representative sample in areas that are radioactively contaminated. Running cables and piping to these locations is very expensive due to the containment requirements. Penetration into and out of an airborne or containment area is complex and costly. The process rooms are built with thick rebar-enforced concrete walls with glove box containment chambers inside. Figure 1 shows highmore » temperature radiation resistance cabling entering the top of a typical glove box. In some case, the entire processing area must be contained in a 'hot cell' where the only access into the chamber is via manipulators. An example is shown in Figure 2. A short range wireless network provides an ideal communication link for transmitting the data from the radiation sensor to a 'clean area', or area absent of any radiation fields or radioactive contamination. Radiation monitoring systems that protect personnel and equipment must meet stringent codes and standards due to the consequences of failure. At first glance a wired system would seem more desirable. Concerns with wireless communication include latency, jamming, spoofing, man in the middle attacks, and hacking. The Department of Energy's Savannah River National Laboratory (SRNL) has developed a prototype wireless radiation air monitoring system that address many of the concerns with wireless and allows quick deployment in radiation and contamination areas. It is stand alone and only requires a standard 120 VAC, 60 Hz power source. It is designed to be mounted or portable. The wireless link uses a National Security Agency (NSA) Suite B compliant wireless network from Fortress Technologies that is considered robust enough to be used for classified data transmission in place of NSA Type 1 devices.« less
2001-10-01
Students in the Young Astronaut Program at the Coca-Cola Space Science Center in Columbus, GA, constructed gloveboxes using the new NASA Student Glovebox Education Guide. The young astronauts used cardboard copier paper boxes as the heart of the glovebox. The paper boxes transformed into gloveboxes when the students pasted poster-pictures of an actual NASA microgravity science glovebox inside and outside of the paper boxes. The young astronauts then added holes for gloves and removable transparent top covers, which completed the construction of the gloveboxes. This image is from a digital still camera; higher resolution is not available.
NASA Technical Reports Server (NTRS)
Tanaka, Kunihiko; Waldie, James; Steinbach, Gregory C.; Webb, Paul; Tourbier, Dietmar; Knudsen, Jeffrey; Jarvis, Christine W.; Hargens, Alan R.
2002-01-01
INTRODUCTION: Current space suits are rigid, gas-pressurized shells that protect astronauts from the vacuum of space. A tight elastic garment or mechanical-counter-pressure (MCP) suit generates pressure by compression and may have several advantages over current space suit technology. In this study, we investigated local microcirculatory effects produced with and without a prototype MCP glove. METHODS: The right hand of eight normal volunteers was studied at normal ambient pressure and during exposure to -50, -100 and -150 mm Hg with and without the MCP glove. Measurements included the pressure against the hand, skin microvascular flow, temperature on the dorsum of the hand, and middle finger girth. RESULTS: Without the glove, skin microvascular flow and finger girth significantly increased with negative pressure, and the skin temperature decreased compared with the control condition. The MCP glove generated approximately 200 mm Hg at the skin surface; all measured values remained at control levels during exposure to negative pressure. DISCUSSION: Without the glove, skin microvascular flow and finger girth increased with negative pressure, probably due to a blood shift toward the hand. The elastic compression of the material of the MCP glove generated pressure on the hand similar to that in current gas-pressurized space suit gloves. The MCP glove prevented the apparent blood shift and thus maintained baseline values of the measured variables despite exposure of the hand to negative pressure.
NASA Technical Reports Server (NTRS)
Bishu, Ram R.
1992-01-01
Human capabilities such as dexterity, manipulability, and tactile perception are unique and render the hand as a very versatile, effective and a multipurpose tool. This is especially true for unknown environments such as the EVA environment. In the microgravity environment interfaces, procedures, and activities are too complex, diverse, and defy advance definition. Under these conditions the hand becomes the primary means of locomotion, restraint, and material handling. Facilitation of these activities, with simultaneous protection from the cruel EVA environment are the two, often conflicting, objectives of glove design. The objectives of this study was (1) to assess the effects of EVA gloves at different pressures on human hand capabilities, (2) to devise a protocol for evaluating EVA gloves, (3) to develop force time relations for a number of EVA glove pressure combinations, and (4) to evaluate two types of launch and entry suit gloves. The objectives were achieved through three experiments. The experiments for achieving objectives 1, 2, and 3 were performed in the glove box in building 34. In experiment 1 three types of EVA gloves were tested at five pressure differentials. A number of performance measures were recorded. In experiment 2 the same gloves as in experiment 1 were evaluated in a reduced number of pressure conditions. The performance measure was endurance time. Six subjects participated in both the experiments. In experiment 3 two types of launch and entry suit gloves were evaluated using a paradigm similar to experiment 1. Currently the data is being analyzed. However for this report some summary analyses have been performed. The results indicate that a) With EVA gloves strength is reduced by nearly 50 percent, b) performance decrements increase with increasing pressure differential, c) TMG effects are not consistent across the three gloves tested, d) some interesting gender glove interactions were observed, some of which may have been due to the extent (or lack of) fit of the glove to the hand, and e) differences in performance exist between partial pressure suit glove and full pressure suit glove, especially in the unpressurized condition.
Walczak, Monika S.; Morales-Gil, Perla; Belashehr, Turia; Kousar, Kiran; Arellanes Lozada, Paulina; Lindsay, Robert
2017-01-01
An approach for acquiring more reliable X-ray photoelectron spectroscopy data from corrosion inhibitor/metal interfaces is described. More specifically, the focus is on metallic substrates immersed in acidic solutions containing organic corrosion inhibitors, as these systems can be particularly sensitive to oxidation following removal from solution. To minimize the likelihood of such degradation, samples are removed from solution within a glove box purged with inert gas, either N2 or Ar. The glove box is directly attached to the load-lock of the ultra-high vacuum X-ray photoelectron spectroscopy instrument, avoiding any exposure to the ambient laboratory atmosphere, and thus reducing the possibility of post immersion substrate oxidation. On this basis, one can be more certain that the X-ray photoelectron spectroscopy features observed are likely to be representative of the in situ submerged scenario, e.g. the oxidation state of the metal is not modified. PMID:28362363
Walczak, Monika S; Morales-Gil, Perla; Belashehr, Turia; Kousar, Kiran; Arellanes Lozada, Paulina; Lindsay, Robert
2017-03-15
An approach for acquiring more reliable X-ray photoelectron spectroscopy data from corrosion inhibitor/metal interfaces is described. More specifically, the focus is on metallic substrates immersed in acidic solutions containing organic corrosion inhibitors, as these systems can be particularly sensitive to oxidation following removal from solution. To minimize the likelihood of such degradation, samples are removed from solution within a glove box purged with inert gas, either N2 or Ar. The glove box is directly attached to the load-lock of the ultra-high vacuum X-ray photoelectron spectroscopy instrument, avoiding any exposure to the ambient laboratory atmosphere, and thus reducing the possibility of post immersion substrate oxidation. On this basis, one can be more certain that the X-ray photoelectron spectroscopy features observed are likely to be representative of the in situ submerged scenario, e.g. the oxidation state of the metal is not modified.
Millsap, Donald W.; Cournoyer, Michael E.; Landsberger, Sheldon; ...
2015-04-23
Nylon 6,6 tensile specimens, conforming to the casing for self-contained fire extinguisher systems, have been irradiated using both an accelerator He ++ ion beam and a 5-Ci PuBe neutron source to model the radiation damage these systems would likely incur over a lifetime of operation within glove boxes. Following irradiation, these samples were mechanically tested using standard practices as described in ASTM D638. The results of the He ++ study indicate that the tensile strength of the nylon specimens undergoes some slight (<10%) degradation while other properties of the samples, such as elongation and tangent modulus, appear to fluctuate withmore » increasing dose levels. The He ++-irradiated specimens also have a noticeable level of discoloration corresponding to increasing levels of dose. The neutron-irradiated samples show a higher degree of mechanical degradation than the He ++-irradiated samples.« less
Power assist EVA glove development
NASA Technical Reports Server (NTRS)
Main, John A.; Peterson, Steven W.; Strauss, Alvin M.
1992-01-01
Structural modeling of the EVA glove indicates that flexibility in the metacarpophalangeal (MCP) joint can be improved by selectively lowering the elasticity of the glove fabric. Two strategies are used to accomplish this. One method uses coil springs on the back of the glove to carry the tension in the glove skin due to pressurization. These springs carry the loads normally borne by the glove fabric, but are more easily deformed. An active system was also designed for the same purpose and uses gas filled bladders attached to the back of the EVA glove that change the dimensions of the back of the glove and allow the glove to bend at the MCP joint, thus providing greater flexibility at this joint. A threshold control scheme was devised to control the action of the joint actuators. Input to the controller was provided by thin resistive pressure sensors placed between the hand and the pressurized glove. The pressure sensors consist of a layer of polyester film that has a thin layer of ink screened on the surface. The resistivity of the ink is pressure dependent, so an extremely thin pressure sensor can be fabricated by covering the ink patch with another layer of polyester film and measuring the changing resistance of the ink with a bridge circuit. In order to sense the force between the hand and the glove at the MCP joint, a sensor was placed on the palmar face of the middle finger. The resultant signal was used by the controller to decide whether to fill or exhaust the bladder actuators on the back of the glove. The information from the sensor can also be used to evaluate the effectiveness of a given control scheme or glove design since the magnitude of the measured pressures gives some idea of the torque required to bend a glove finger at the MCP joint. Tests of this actuator, sensor, and control system were conducted in an 57.2 kPa glove box by performing a series of 90 degree finger bends with a glove without an MCP joint assembly, a glove with the coil spring assembly, and with the four fingered actuated glove. The tests of these three glove designs confirm the validity of the model.
Growth of 2 Inch Eu-doped SrI2 single crystals for scintillator applications
NASA Astrophysics Data System (ADS)
Yoshikawa, Akira; Shoji, Yasuhiro; Yokota, Yuui; Kurosawa, Shunsuke; Hayasaka, Shoki; Chani, Valery I.; Ito, Tomoki; Kamada, Kei; Ohashi, Yuji; Kochurikhin, Vladimir
2016-10-01
A vertical Bridgman (VB) crystal growth process was established using modified micro-pulling-down (μ-PD) crystal growth system with a removable chamber that was developed for the growth of deliquescent halide single crystals because conventional μ-PD method does not allow growth of large bulk single crystals. Eu:SrI2 crystals were grown from the melt of (Sr0.98Eu0.02)I2 composition using carbon crucibles. Undoped μ-PD SrI2 crystals were used as seeds that were affixed to the bottom of the crucible. All the preparations preceding the growths and the hot zone assembling were performed in a glove box with Ar gas. Then the removable chamber was taken out of the glove box, attached to the μ-PD system, connected with a Turbo Molecular pump, and evacuated down to 10-4 Pa at 300 °C. After the baking procedure, high purity Ar gas (6N) was injected into the chamber. The crucible was heated by a high frequency induction coil up to the melting point of Eu:SrI2. After melting the starting materials, the crucible was displaced in downward direction for the crystal growth and then cooled down to room temperature. Thus, 2 in. and crack-free Eu:SrI2 bulk crystals were produced. The crystals had high transparency and did not contain any visible inclusions. The crystals were cut and polished in the glove box and then sealed in an aluminum container with an optical window for characterization. The details of the crystal growth are discussed.
Film Grain-Size Related Long-Term Stability of Inverted Perovskite Solar Cells.
Chiang, Chien-Hung; Wu, Chun-Guey
2016-09-22
The power conversion efficiency (PCE) of the perovskite solar cell is high enough to be commercially viable. The next important issue is the stability of the device. This article discusses the effect of the perovskite grain-size on the long-term stability of inverted perovskite solar cells. Perovskite films composed of various sizes of grains were prepared by controlling the solvent annealing time. The grain-size related stability of the inverted cells was investigated both in ambient atmosphere at relative humidity of approximately 30-40 % and in a nitrogen filled glove box (H 2 O<0.1 ppm, O 2 <10 ppm). The PCE of the solar cell based on a perovskite film having the grain size larger than 1 μm (D-10) decreases less than 10 % with storage in a glove box and less than 15 % when it was stored under an ambient atmosphere for 30 days. However, the cell using the perovskite film composed of small (∼100 nm) perovskite grains (D-0) exhibits complete loss of PCE after storage under the ambient atmosphere for only 15 days and a PCE loss of up to 70 % with storage in the glove box for 30 days. These results suggest that, even under H 2 O-free conditions, the chemical- and thermal-induced production of pin holes at the grain boundaries of the perovskite film could be the reason for long-term instability of inverted perovskite solar cells. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Glove thermal insulation: local heat transfer measures and relevance.
Sari, Hayet; Gartner, Maurice; Hoeft, Alain; Candas, Victor
2004-09-01
When exposed to cold, the hands need to be protected against heat loss not only in order to reduce thermal discomfort, but also to keep their efficiency. Although gloves are usually the most common protection, their thermal insulation is generally unknown. The aim of this study was to measure the heat losses from a gloved hand with a special interest in local variations. Using a calorimetric hand placed in a cold box, several types of gloves were tested. The results indicated that depending on the glove and on the area covered the heat loss reduction may vary from almost 60% to 90%. When the least efficient pair of gloves was excluded, heat exchange coefficients varied from 1.8 to 4.8 W/m2 per degrees C for the palm and from 4.2 to 6.2 W/m2 per degrees C for the back of the hand. The three medium fingers seemed to be equally treated, with a heat exchange coefficient variation of 6.3-9.0 W/m2 per degrees C. The thumb and the little finger, which require better insulation, exhibited higher local heat transfer coefficients of 8.3-12.7 W/m2 per degrees C. Some practical aspects are evoked.
Control of a powered prosthetic device via a pinch gesture interface
NASA Astrophysics Data System (ADS)
Yetkin, Oguz; Wallace, Kristi; Sanford, Joseph D.; Popa, Dan O.
2015-06-01
A novel system is presented to control a powered prosthetic device using a gesture tracking system worn on a user's sound hand in order to detect different grasp patterns. Experiments are presented with two different gesture tracking systems: one comprised of Conductive Thimbles worn on each finger (Conductive Thimble system), and another comprised of a glove which leaves the fingers free (Conductive Glove system). Timing tests were performed on the selection and execution of two grasp patterns using the Conductive Thimble system and the iPhone app provided by the manufacturer. A modified Box and Blocks test was performed using Conductive Glove system and the iPhone app provided by Touch Bionics. The best prosthetic device performance is reported with the developed Conductive Glove system in this test. Results show that these low encumbrance gesture-based wearable systems for selecting grasp patterns may provide a viable alternative to EMG and other prosthetic control modalities, especially for new prosthetic users who are not trained in using EMG signals.
Students build glovebox at Space Science Center
NASA Technical Reports Server (NTRS)
2001-01-01
Students in the Young Astronaut Program at the Coca-Cola Space Science Center in Columbus, GA, constructed gloveboxes using the new NASA Student Glovebox Education Guide. The young astronauts used cardboard copier paper boxes as the heart of the glovebox. The paper boxes transformed into gloveboxes when the students pasted poster-pictures of an actual NASA microgravity science glovebox inside and outside of the paper boxes. The young astronauts then added holes for gloves and removable transparent top covers, which completed the construction of the gloveboxes. This image is from a digital still camera; higher resolution is not available.
The Reduction of Sulfuryl Chloride at Teflon-Bonded Carbon Cathodes
1980-07-01
titrated mulating cathodes, along with their BET surface potentiometrically with standardized silver nitrate areas. Shawinigan black possesses the...assembly steps when individually dissolved can be titrated through were accomplished in the glove box. iodimetry or iodometry, respectively (7). If
Augmented robotic device for EVA hand manoeuvres
NASA Astrophysics Data System (ADS)
Matheson, Eloise; Brooker, Graham
2012-12-01
During extravehicular activities (EVAs), pressurised space suits can lead to difficulties in performing hand manoeuvres and fatigue. This is often the cause of EVAs being terminated early, or taking longer to complete. Assistive robotic gloves can be used to augment the natural motion of a human hand, meaning work can be carried out more efficiently with less stress to the astronaut. Lightweight and low profile solutions must be found in order for the assistive robotic glove to be easily integrated with a space suit pressure garment. Pneumatic muscle actuators combined with force sensors are one such solution. These actuators are extremely light, yet can output high forces using pressurised gases as the actuation drive. Their movement is omnidirectional, so when combined with a flexible exoskeleton that itself provides a degree of freedom of movement, individual fingers can be controlled during flexion and extension. This setup allows actuators and other hardware to be stored remotely on the user's body, resulting in the least possible mass being supported by the hand. Two prototype gloves have been developed at the University of Sydney; prototype I using a fibreglass exoskeleton to provide flexion force, and prototype II using torsion springs to achieve the same result. The gloves have been designed to increase the ease of human movements, rather than to add unnatural ability to the hand. A state space control algorithm has been developed to ensure that human initiated movements are recognised, and calibration methods have been implemented to accommodate the different characteristics of each wearer's hands. For this calibration technique, it was necessary to take into account the natural tremors of the human hand which may have otherwise initiated unexpected control signals. Prototype I was able to actuate the user's hand in 1 degree of freedom (DOF) from full flexion to partial extension, and prototype II actuated a user's finger in 2 DOF with forces achieved comparable to those of a natural, healthy hand. The minimum mass held by the user on the hand was 240 g, with remote hardware, including a compressed air bottle, having a further mass of 1.6 kg. These results indicate that the design is able to augment human motion in a low profile, low mass package, and could be a valuable addition to a space suit during an EVA.
NASA Astrophysics Data System (ADS)
Penmetcha, Anirudh Raju
Significant efficiency increases are being made for bulk heterojunction organic photovoltaic prototype devices with world records at 11%. However the chlorinated solvents most frequently used in prototype manufacture would cause local health and safety concerns or large scale environmental pollution upon expansion of these techniques for commercialization. Moreover, research to bridge prototype and large-scale production of these solar cells is still in its infancy. Most prototype devices are made in inert glove box environments using spin-coating. There is a need to develop a non-toxic ink and incorporate it into a material deposition system that can be used in mass production. In this thesis, P3HT:PCBM organic photovoltaic devices were fabricated with the help of inkjet printing. P3HT:PCBM blends were dissolved in organic solvent systems, and this solution was used as the ink for the printer. The "coffee-ring effect" as well as the effect of inkjet printing parameters on film formation were highlighted - thus the inkjet printing method was validated as a stepping stone between lab-scale production of OPVs and large-scale roll-to-roll manufacturing. To address the need of a non-toxic ink, P3HT:PCBM blends were then dispersed in water, using the miniemulsion method. The nanoparticles were characterized for their size, as well as the blending between the P3HT and PCBM within the nanoparticle. These dispersions were then converted into inks. Finally, these nanoparticle inks were inkjet-printed to fabricate OPV devices. Based on the results obtained here, tentative "next steps" have been outlined in order to improve upon this research work, in the future.
1980-07-01
Edmont-Wilson 37-165 NBR .056 (22) 10 J Edmont-Wilson 26-665 Rubber .046 (18) 10 K Edmont-Wilson 36-755 Rubber .102 (40) 10 L Surety 10-112L Nitrile...4367 Dickenson & Company Charleston SC 29405 Coshocton OH 43812 International Playtex Company Surety Rubber Company Industrial Gloves Division P.O. Box...B Pioneer A-10 Nitrile .025 (10) 9 C Pioneer A-15 Nitrile .038 (15) 9 D Norton NSN 8415-00-753-6551 Butyl rubber .076 (30) M E Norton NSN 8415-01-025
Mechanical counter pressure on the arm counteracts adverse effects of hypobaric exposures
NASA Technical Reports Server (NTRS)
Tanaka, Kunihiko; Limberg, Ryan; Webb, Paul; Reddig, Mike; Jarvis, Christine W.; Hargens, Alan R.
2003-01-01
INTRODUCTION: Current space suits have limited movement due to gas pressurization during exposure to the vacuum of space. Alternatively, if pressure is applied by an elastic garment vs. pneumatic garment to produce mechanical counter pressure (MCP), several advantages are possible. In this study, we investigate local microcirculatory and other effects produced with and without a prototype MCP glove and sleeve during exposure to varying levels of vacuum. METHODS: The entire arms of eight male volunteers were studied at normal ambient pressure and during 5 min exposures to -50, -100, and -150 mm Hg with and without the MCP glove and sleeve. Pressure distribution, skin microvascular flow, and temperature were measured. RESULTS: The MCP glove and sleeve generated over 200 mm Hg on the middle finger, dorsum of the hand, and the wrist. However, pressure was significantly lower on the forearm and the upper arm. Without the glove and sleeve, only two of eight subjects tolerated -100 mm Hg. Also, no subject tolerated -150 mm Hg. However, subjects tolerated all vacuum pressures wearing the glove and sleeve. Skin microvascular flow and temperature remained within control values with the glove and sleeve at a chamber pressure of -150 mm Hg. DISCUSSION: The MCP glove and sleeve counteracts adverse effects of vacuum exposures due to lower pressure differentials. Pressure levels over the hand and wrist are similar to those of the current U.S. space suit glove and sleeve, but additional development is required to increase MCP over the forearm and upper arm.
JOVE Pilot Research Study in Astronomy and Microgravity Sciences
NASA Technical Reports Server (NTRS)
Strauss, Alvin M.; Hmelo, Anthony; Peterson, Steven
1996-01-01
The purpose of this project was to develop hardware and software facilities for evaluating the biomechanical interactions between human hands and space suit gloves. The first task was to measure finger joint angles inside space suit gloves. A preliminary survey identified three potential systems which could be used in the proposed study. In response to the current market situation, a glove for measuring the positions of the hand inside a space suit has been developed. A prototype of the glove has been constructed to demonstrate its sensing technologies. There are two types of sensors in the glove. The positions of the fingers are measured using bend sensors based on the CyberGlove design. This sensor consists of two strain gages mounted to a 0.003 inch thick mylar sheet. The sensor is encapsulated using 0.001 inch kapton film to give it sufficient rigidity. Along gage is used to average the strain generated in the sensor due to bending This average strain produces an output signal proportional to the angle of the bend. The force sensor consists of conductive ink sandwiched between two plastic sheets. An electrode is printed on one of the plastic sheets using silver ink. The resistance of the ink is sensitive to pressure.
Gentilli, Sergio; Morgandoa, Andrea; Velardocchia, Mauro; Pessione, Silvia; Pizzorno, Chiara
2007-01-01
The authors present their prototype of a system for electrical conduction in direct contact with laparoscopic tools, devised, designed and produced by them at the Politecnico di Torino Department of Mechanical Engineering. The system consists of a two-sided plate, one side being a non-conducting adhesive surface to stick to the surgical glove and the other a thin, flexible conductor shell. The authors used the instrument with surgical tools with metal handles during 4 laparoscopic procedures. Nowadays the method commonly used to electrify laparoscopic tools is by using a wire plugged to a fixed conducting point on the instrument. The prototype described here was devised and produced to avoid some of the awkwardness encountered during the numerous manoeuvres required to connect and disconnect the wire at the time of surgical intervention. This device permits the direct transfer (by contact) of electrical energy from the wire to surgical tools. The advantage is greater rapidity in changing surgical tools, with the possibility of immediately obtaining an electrified instrument in the surgeon's hand.
Develop and Manufacture an Ergonomically Sound Glovebox Glove Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawton, Cindy M.
Ergonomic injury and radiation exposure are two safety concerns for the Plutonium Facility at Los Alamos National Laboratory (LANL). This facility employs the largest number of gloveboxes (GB) at LANL with approximately 6000 gloves installed. The current GB glove design dates back to the 1960’s and is not based on true hand anatomy, revealing several issues: short fingers, inappropriate length from the wrist to finger webbing, nonexistent joint angles and incorrect thumb placement. These design flaws are directly related to elbow (lateral epicondylitis) and thumb (DeQuervain’s tenosynovitis) injuries. The current design also contributes to increased wear on the glove, causingmore » unplanned glove openings (failures) which places workers at risk of exposure. An improved glovebox glove design has three significant benefits: 1) it will reduce the risk of injury, 2) it will improve comfort and productivity, and 3) it will reduce the risk of a glovebox failures. The combination of these three benefits has estimated savings of several million dollars. The new glove design incorporated the varied physical attributes of workers ranging from the 5 th percentile female to the 95th percentile male. Anthropometric hand dimensions along with current GB worker dimensions were used to develop the most comprehensive design specifications for the new glove. Collaboration with orthopedic hand surgeons also provided major contributtions to the design. The new glovebox glove was developed and manufactured incorporating over forty dimensions producing the most comprehensive ergonomically sound design. The new design received a LANL patent (patent attorney docket No: LANS 36USD1 “Protective Glove”, one of 20 highest patents awarded by the Richard P. Feynman Center for Innovation. The glove dimensions were inputed into a solid works model which was used to produce molds. The molds were then shipped to a glove manufacturer for production of the new glovebox gloves. The new glovebox gloves were tested against the presently used glovebox gloves for design validity. The testing included a subjective survey and four dexterity tests. The prototype was statistically significant in 3 dexterity tests and favorable on 8 out of 10 survey questions. The more ergonomically sound glovebox glove will improve worker comfort, mitigate glovebox worker injuries, and reduce glove breaches.« less
Tactility as a function of grasp force: Effects of glove, orientation, pressure, load, and handle
NASA Technical Reports Server (NTRS)
Bishu, Ram R.; Bronkema, Lisa A.; Garcia, Dishayne; Klute, Glenn; Rajulu, Sudhakar
1994-01-01
One of the reasons for reduction in performance when gloves are donned is the lack of tactile sensitivity. It was argued that grasping force for a weight to be grasped will be a function of the weight to be lifted and the hand conditions. It was further reasoned that the differences in grasping force for various hand conditions will be a correlate of the tactile sensitivity of the corresponding hand conditions. The objective of this experiment, therefore, was to determine the effects of glove type, pressure, and weight of load on the initial grasping force and stable grasping force. It was hypothesized that when a person grasps an object, he/she grasps very firmly initially and then releases the grasp slightly after realizing what force is needed to maintain a steady grasp. This would seem to be particularly true when a person is wearing a glove and has lost some tactile sensitivity and force feedback during the grasp. Therefore, the ratio of initial force and stable force and the stable force itself would represent the amount of tactile adjustment that is made when picking up an object, and this adjustment should vary with the use of gloves. A dynamometer was fabricated to measure the grasping force; the tests were performed inside a glove box. Four female and four male subjects participated in the study, which measured the effects of four variables: load effect, gender effect, glove type, and pressure variance. The only significant effects on the peak and stable force were caused by gender and the weight of the load lifted. Neither gloves nor pressure altered these forces when compared to a bare-handed condition, as was suspected before the test. It is possible that gloves facilitate in holding due to coefficient of friction while they deter in peak grasp strength.
An Approach for Performance Assessments of Extravehicular Activity Gloves
NASA Technical Reports Server (NTRS)
Aitchison, Lindsay; Benosn, Elizabeth
2014-01-01
The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for unique mission scenarios outside the Space Shuttle and International Space Station (ISS) Program realm of experience. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Game-Changing Technology group provided start-up funding for the High Performance EVA Glove (HPEG) Project in the spring of 2012. The overarching goal of the HPEG Project is to develop a robust glove design that increases human performance during EVA and creates pathway for future implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability by 100%, and decreasing the potential of gloves to cause injury during use. The HPEG Project focused initial efforts on identifying potential new technologies and benchmarking the performance of current state of the art gloves to identify trends in design and fit leading to establish standards and metrics against which emerging technologies can be assessed at both the component and assembly levels. The first of the benchmarking tests evaluated the quantitative mobility performance and subjective fit of two sets of prototype EVA gloves developed ILC Dover and David Clark Company as compared to the Phase VI. Both companies were asked to design and fabricate gloves to the same set of NASA provided hand measurements (which corresponded to a single size of Phase Vi glove) and focus their efforts on improving mobility in the metacarpal phalangeal and carpometacarpal joints. Four test subjects representing the design-to hand anthropometry completed range of motion, grip/pinch strength, dexterity, and fit evaluations for each glove design in pressurized conditions, with and without thermal micrometeoroid garments (TMG) installed. This paper provides a detailed description of hardware and test methodologies used and lessons learned.
11. SIDE VIEW OF INSTALLATION OF A CONTINUOUS ROTARYTUBE HYDROFLUORINATOR ...
11. SIDE VIEW OF INSTALLATION OF A CONTINUOUS ROTARY-TUBE HYDROFLUORINATOR LOCATED IN ROOM 146. THE HYDROFLUORINATOR IS BEING INSTALLED INSIDE A GLOVE BOX. HYDROFLUORINATION CONVERTED PLUTONIUM OXIDE TO PLUTONIUM TETRAFLUORIDE. (1/11/62) - Rocky Flats Plant, Plutonium Recovery & Fabrication Facility, North-central section of plant, Golden, Jefferson County, CO
Fabrication & characterization of thin film Perovskite solar cells under ambient conditions
NASA Astrophysics Data System (ADS)
Shah, Vivek T.
High efficiency solar cells based on inorganic materials such as silicon have been commercialized and used to harness energy from the sun and convert it into electrical energy. However, they are energy-intensive and rigid. Thin film solar cells based on inorganic-organic hybrid lead halide perovskite compounds have the potential to be a disruptive technology in the field of renewable energy sector of the economy. Perovskite solar cell (PSC) technology is a viable candidate for low-cost large scale production as it is solution processable at low temperature on a flexible substrate. However, for commercialization, PSCs need to compete with the cost and efficiency of crystalline silicon solar cells. High efficiency PSCs have been fabricated under highly controlled conditions in what is known as a glove-box, which adds to the cost of fabrication of PSCs. This additional cost can be significantly reduced by eliminating the use of glove-box for fabrication. Therefore, in this work, thin film PSCs were fabricated at ambient conditions on glass substrates. A power conversion efficiency of 5.6% was achieved with optimum fabrication control and minimal exposure to moisture.
NASA Technical Reports Server (NTRS)
Reid, Christopher R.; McFarland, Shane M.
2015-01-01
Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals that 58% of total astronaut hand and arm injuries from NBL training between 1993 and 2010 occurred either to the fingernail, MCP, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure force acting on the fingers and hand within pressurized gloves and other variables such as blood perfusion, skin temperature, humidity, fingernail strain, skin moisture, among others. Tasks were performed gloved and ungloved in a pressurizable glove box. The test demonstrated that fingernails saw greater transverse strain levels for tension or compression than for longitudinal strain, even during axial fingertip loading. Blood perfusion peaked and dropped as the finger deformed during finger presses, indicating an initial dispersion and decrease of blood perfusion levels. Force sensitive resistors to force plate comparisons showed similar force curve patterns as fingers were depressed, indicating suitable functionality for future testing. Strategies for proper placement and protection of these sensors for ideal data collection and longevity through the test session were developed and will be implemented going forward for future testing.
What boxing-related stimuli reveal about response behaviour.
Ottoboni, Giovanni; Russo, Gabriele; Tessari, Alessia
2015-01-01
When two athletes meet inside the ropes of the boxing ring to fight, their cognitive systems have to respond as quickly as possible to a manifold of stimuli to assure victory. In the present work, we studied the pre-attentive mechanisms, which form the basis of an athlete's ability in reacting to an opponent's punches. Expert boxers, beginner boxers and people with no experience of boxing performed a Simon-like task where they judged the colour of the boxing gloves worn by athletes in attack postures by pressing two lateralised keys. Although participants were not instructed to pay attention to the direction of the punches, beginner boxers' responses resembled a defence-related pattern, expert boxers' resembled counterattacks, whereas non-athletes' responses were not influenced by the unrelated task information. Results are discussed in the light of an expertise-related action simulation account.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cournoyer, Michael E; George, Gerald L; Dodge, Robert L
Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). Radiation shielding is commonly used to protect the glovebox worker from unintentional direct and secondary radiation exposure, while working with plutonium-238 and plutonium-239. In these environments, low-energy photons, i.e., those less than 250 keY, are encountered.more » Shielding glove box gloves are traditionally composed of lead-based materials, but these are now considered hazardous waste. This has prompted the development of new, nonhazardous- shielding gJovebox gloves. No studies, however, have investigated the effectiveness of these new glovebox gloves. We examined both leaded and nonhazardous- shielding glovebox gloves and compared their attenuation effectiveness over the energy range of interest at TA-55. All measurements are referenced to lead sheets, allowing direct comparisons to the common industry standard of 0.1 mm lead equivalent material. The attenuation properties of both types of glovebox gloves vary with energy, making it difficult for manufacturers to claim lead equivalency across the entire energy range used at TA-55. The positions of materials' photon energy absorption edges, which are particularly important to improved attenuation performance, depending upon the choice of radiation energy range, are discussed. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations.« less
Tactile Data Entry for Extravehicular Activity
NASA Technical Reports Server (NTRS)
Adams, Richard J.; Olowin, Aaron B.; Hannaford, Blake; Sands, O Scott
2012-01-01
In the task-saturated environment of extravehicular activity (EVA), an astronaut's ability to leverage suit-integrated information systems is limited by a lack of options for data entry. In particular, bulky gloves inhibit the ability to interact with standard computing interfaces such as a mouse or keyboard. This paper presents the results of a preliminary investigation into a system that permits the space suit gloves themselves to be used as data entry devices. Hand motion tracking is combined with simple finger gesture recognition to enable use of a virtual keyboard, while tactile feedback provides touch-based context to the graphical user interface (GUI) and positive confirmation of keystroke events. In human subject trials, conducted with twenty participants using a prototype system, participants entered text significantly faster with tactile feedback than without (p = 0.02). The results support incorporation of vibrotactile information in a future system that will enable full touch typing and general mouse interactions using instrumented EVA gloves.
2014-01-01
Background It is thought that therapy should be functional, be highly repetitive, and promote afferent input to best stimulate hand motor recovery after stroke, yet patients struggle to access such therapy. We developed the MusicGlove, an instrumented glove that requires the user to practice gripping-like movements and thumb-finger opposition to play a highly engaging, music-based, video game. The purpose of this study was to 1) compare the effect of training with MusicGlove to conventional hand therapy 2) determine if MusicGlove training was more effective than a matched form of isometric hand movement training; and 3) determine if MusicGlove game scores predict clinical outcomes. Methods 12 chronic stroke survivors with moderate hemiparesis were randomly assigned to receive MusicGlove, isometric, and conventional hand therapy in a within-subjects design. Each subject participated in six one-hour treatment sessions three times per week for two weeks, for each training type, for a total of 18 treatment sessions. A blinded rater assessed hand impairment before and after each training type and at one-month follow-up including the Box and Blocks (B & B) test as the primary outcome measure. Subjects also completed the Intrinsic Motivation Inventory (IMI). Results Subjects improved hand function related to grasping small objects more after MusicGlove compared to conventional training, as measured by the B & B score (improvement of 3.21±3.82 vs. -0.29±2.27 blocks; P=0.010) and the 9 Hole Peg test (improvement of 2.14±2.98 vs. -0.85±1.29 pegs/minute; P=0.005). There was no significant difference between training types in the broader assessment batteries of hand function. Subjects benefited less from isometric therapy than MusicGlove training, but the difference was not significant (P>0.09). Subjects sustained improvements in hand function at a one month follow-up, and found the MusicGlove more motivating than the other two therapies, as measured by the IMI. MusicGlove games scores correlated strongly with the B & B score. Conclusions These results support the hypothesis that hand therapy that is engaging, incorporates high numbers of repetitions of gripping and thumb-finger opposition movements, and promotes afferent input is a promising approach to improving an individual’s ability to manipulate small objects. The MusicGlove provides a simple way to access such therapy. PMID:24885076
Friedman, Nizan; Chan, Vicky; Reinkensmeyer, Andrea N; Beroukhim, Ariel; Zambrano, Gregory J; Bachman, Mark; Reinkensmeyer, David J
2014-04-30
It is thought that therapy should be functional, be highly repetitive, and promote afferent input to best stimulate hand motor recovery after stroke, yet patients struggle to access such therapy. We developed the MusicGlove, an instrumented glove that requires the user to practice gripping-like movements and thumb-finger opposition to play a highly engaging, music-based, video game. The purpose of this study was to 1) compare the effect of training with MusicGlove to conventional hand therapy 2) determine if MusicGlove training was more effective than a matched form of isometric hand movement training; and 3) determine if MusicGlove game scores predict clinical outcomes. 12 chronic stroke survivors with moderate hemiparesis were randomly assigned to receive MusicGlove, isometric, and conventional hand therapy in a within-subjects design. Each subject participated in six one-hour treatment sessions three times per week for two weeks, for each training type, for a total of 18 treatment sessions. A blinded rater assessed hand impairment before and after each training type and at one-month follow-up including the Box and Blocks (B & B) test as the primary outcome measure. Subjects also completed the Intrinsic Motivation Inventory (IMI). Subjects improved hand function related to grasping small objects more after MusicGlove compared to conventional training, as measured by the B & B score (improvement of 3.21±3.82 vs. -0.29±2.27 blocks; P=0.010) and the 9 Hole Peg test (improvement of 2.14±2.98 vs. -0.85±1.29 pegs/minute; P=0.005). There was no significant difference between training types in the broader assessment batteries of hand function. Subjects benefited less from isometric therapy than MusicGlove training, but the difference was not significant (P>0.09). Subjects sustained improvements in hand function at a one month follow-up, and found the MusicGlove more motivating than the other two therapies, as measured by the IMI. MusicGlove games scores correlated strongly with the B & B score. These results support the hypothesis that hand therapy that is engaging, incorporates high numbers of repetitions of gripping and thumb-finger opposition movements, and promotes afferent input is a promising approach to improving an individual's ability to manipulate small objects. The MusicGlove provides a simple way to access such therapy.
NASA Astrophysics Data System (ADS)
Roy, G.; Llorca, F.; Lanier, G.; Lamalle, S.; Beaulieu, J.; Antoine, P.; Martinuzzi, P.
2006-08-01
This paper is a technical presentation about a new experimental facility recently developed at CEA/Valduc, BAGHEERA, a French acronym for “Hopkinson And High Speed Experiments Glove Box”. This facility is used since mid-2003 to characterize the physical and mechanical behaviour of actinides under high dynamic loadings. For this purpose, four basic experimental devices are confined inside a single glove box: a 50 mm bore diameter single stage light gas gun, two compression and torsion split Hopkinson bars (SHPB and TSHB respectively) and a Taylor test device (TTD). Design and technical data on the experimental equipment are addressed, with a particular emphasis on the gas gun specific features due to actinide applications.
Iwamuro, B T; Fischer, H C; Kamper, D G
2011-01-01
The purpose of this study was to investigate whether active range of finger motion could be increased through the introduction of passive, external extension joint torques in stroke survivors. Five chronic stroke survivors with severe hand impairment resulting from hemiparesis took part in the study. Participants completed 2 experimental sessions in which hand movement and function were assessed. In one session, they wore a custom orthotic glove (X-Glove) that passively supplied extension torques to the joints of the fingers. In the second session, they performed the same tasks as in the other session, but without the glove. Outcome measures consisted of active range of motion, distance of the fingertip from the hand, selected tasks from the Graded Wolf Motor Function Test (GWMFT), and the Box and Blocks (BB) test. Primary results with and without the glove were compared using paired t tests with a Bonferroni correction. Active range of motion improved significantly by over 50%, from 4.4 cm to 6.7 cm, when the X-Glove was worn (P = .011). The distance of the fingertip from the metacarpophalangeal joint increased by an average of 2.2 cm for 4 of the subjects, although this change was not significant across all 5 subjects (P = .123). No significant differences were observed in the BB or GWMFT whether the X-Glove was worn or not. Introduction of passive extension torque can improve active range of motion for the fingers, even in chronic stroke survivors with substantial hand impairment. The increased range of motion would facilitate therapeutic training of the hand, potentially even in the home environment, although the bulk of the orthosis should be minimized to facilitate interactions with real objects.
Boxing headguard performance in punch machine tests.
McIntosh, Andrew S; Patton, Declan A
2015-09-01
The paper presents a novel laboratory method for assessing boxing headguard impact performance. The method is applied to examine the effects of headguards on head impact dynamics and injury risk. A linear impactor was developed, and a range of impacts was delivered to an instrumented Hybrid III head and neck system both with and without an AIBA (Association Internationale de Boxe Amateur)-approved headguard. Impacts at selected speeds between 4.1 and 8.3 m/s were undertaken. The impactor mass was approximately 4 kg and an interface comprising a semirigid 'fist' with a glove was used. The peak contact forces were in the range 1.9-5.9 kN. Differences in head impact responses between the Top Ten AIBA-approved headguard and bare headform in the lateral and forehead tests were large and/or significant. In the 8.3 m/s fist-glove impacts, the mean peak resultant headform accelerations for bare headform tests was approximately 130 g compared with approximately 85 g in the forehead impacts. In the 6.85 m/s bare headform impacts, mean peak resultant angular head accelerations were in the range of 5200-5600 rad/s(2) and almost halved by the headguard. Linear and angular accelerations in 45° forehead and 60° jaw impacts were reduced by the headguard. The data support the opinion that current AIBA headguards can play an important role in reducing the risk of concussion and superficial injury in boxing competition and training. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Economic Analysis of National Nuclear Security Administration (NNSA) Modernization Alternatives
2007-11-01
without nuclear testing; works to reduce global danger from weapons of mass destruction; provides the U.S. Navy with safe and effective nuclear...SFE) covers the acquisition of glove boxes, long-lead facility, and actinide chemistry/materials characterization (AC/MC) equipment whose uniqueness...Hazard Category II AC/MC and actinide Research and Development operations, special nuclear 5 Babcock
Aids to Develop Throwing and Catching Skills.
ERIC Educational Resources Information Center
Schilling, Mary Lou, Ed.
1982-01-01
THE FOLLOWING IS THE FULL TEXT OF THIS DOCUMENT: STICKER MITT: (Creative Concepts Unlimited, P.O. Box 176, Elmhurst, IL 60126) A plastic mitt with small suction cups on the palm of the glove so that a plastic ball will easily adhere to it. This ensures a successful experience for children who have never caught a ball!! Approximate cost: $8.95.…
NASA Astrophysics Data System (ADS)
Farmer, J. D.; Nunez, J. I.; Sellar, R. G.; Gardner, P. B.; Manatt, K. S.; Dingizian, A.; Dudik, M. J.; McDonnell, G.; Le, T.; Thomas, J. A.; Chu, K.
2011-12-01
The Multispectral Microscopic Imager (MMI) is a prototype instrument presently under development for future astrobiological missions to Mars. The MMI is designed to be a arm-mounted rover instrument for use in characterizing the microtexture and mineralogy of materials along geological traverses [1,2,3]. Such geological information is regarded as essential for interpreting petrogenesis and geological history, and when acquired in near real-time, can support hypothesis-driven exploration and optimize science return. Correlated microtexure and mineralogy also provides essential data for selecting samples for analysis with onboard lab instruments, and for prioritizing samples for potential Earth return. The MMI design employs multispectral light-emitting diodes (LEDs) and an uncooled focal plane array to achieve the low-mass (<1kg), low-cost, and high reliability (no moving parts) required for an arm-mounted instrument on a planetary rover [2,3]. The MMI acquires multispectral, reflectance images at 62 μm/pixel, in which each image pixel is comprised of a 21-band VNIR spectrum (0.46 to 1.73 μm). This capability enables the MMI to discriminate and resolve the spatial distribution of minerals and textures at the microscale [2, 3]. By extending the spectral range into the infrared, and increasing the number of spectral bands, the MMI exceeds the capabilities of current microimagers, including the MER Microscopic Imager (MI); 4, the Phoenix mission Robotic Arm Camera (RAC; 5) and the Mars Science Laboratory's Mars Hand Lens Imager (MAHLI; 6). In this report we will review the capabilities of the MMI by highlighting recent lab and field applications, including: 1) glove box deployments in the Astromaterials lab at Johnson Space Center to analyze Apollo lunar samples; 2) GeoLab glove box deployments during the 2011 Desert RATS field trials in northern AZ to characterize analog materials collected by astronauts during simulated EVAs; 3) field deployments on Mauna Kea Volcano, Hawaii, during NASA's 2010 ISRU field trials, to analyze materials at the primary feedstock mining site; 4) lab characterization of geological samples from a complex, volcanic-hydrothermal terrain in the Cady Mts., SE Mojave Desert, California. We will show how field and laboratory applications have helped drive the development and refinement of MMI capabilities, while identifying synergies with other potential payload instruments (e.g. X-ray Diffraction) for solving real geological problems.
Compression under a mechanical counter pressure space suit glove
NASA Technical Reports Server (NTRS)
Waldie, James M A.; Tanaka, Kunihiko; Tourbier, Dietmar; Webb, Paul; Jarvis, Christine W.; Hargens, Alan R.
2002-01-01
Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, p<0.001). There was no significant change in glove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.
Compression under a mechanical counter pressure space suit glove.
Waldie, James M A; Tanaka, Kunihiko; Tourbier, Dietmar; Webb, Paul; Jarvis, Christine W; Hargens, Alan R
2002-12-01
Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, p<0.001). There was no significant change in glove compression with the chamber pressure reductions. The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.
1969-07-27
S69-45002 (26 July 1969) --- A close-up view of the lunar rocks contained in the first Apollo 11 sample return container. The rock box was opened for the first time in the Vacuum Laboratory of the Manned Spacecraft Center’s Lunar Receiving Laboratory, Building 37, at 3:55 p.m. (CDT), Saturday, July 26, 1969. The gloved hand gives an indication of size. This box also contained the Solar Wind Composition experiment (not shown) and two core tubes for subsurface samples (not shown). These lunar samples were collected by astronauts Neil A. Armstrong and Edwin E. Aldrin Jr. during their lunar surface extravehicular activity on July 20, 1969.
Service Wear Test Evaluation of Structural/Proximity Firefighters Gloves
1991-06-05
CLOTHING AND TEXTILE RESEARCH FACILITY NATICK, MASSACHUSETTS Approved for public release; Technical Report No. NCTRF 188 distribution unlimited. 92 12 ;e3...ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER NAVY CLOTHING AND TEXTILE RESEARCH FACILITY P.O. BOX 59 NCTRF REPORT NO...CODE APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED 13. ABSTRACT (Maximum 200 words) The Navy Clothing and Textile Research Facility (NCTRF
JOVE Pilot Research Study in Astronomy and Microgravity Sciences
NASA Technical Reports Server (NTRS)
Strauss, Alvin M.; Hmelo, Anthony; Vlasse; Peterson, Steven
1995-01-01
The purpose of this project was to develop hardware and software facilities for evaluating the biomechanical interactions between human hands and space suit gloves. We have constructed a prototype of the glove to demonstrate its sensing technologies. There are two types of sensors in the glove. The positions of the fingers are measured using bend sensors based on the CyberGlove design. This sensor consists of two strain gages mounted to a 0.003 inch thick mylar sheet. The sensor is encapsulated using 0.001 inch kapton film to give it sufficient rigidity. A long gage is used to average the strain generated in the sensor due to bending. This average strain produces an output signal proportional to the angle of the bend. The force sensor, FSR, is manufactured by Interlink. It consists of conductive ink sandwiched between two plastic sheets. An electrode is printed on one of the plastic sheets using silver ink. When the electrode makes contact, current flows through the conductive ink. The resistance of the ink pad is sensitive to pressure. We have also developed circuits for exciting and measuring the sensors. The current version requires a single sided twelve volt power supply which is one inch long and 0.4 inches in diameter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richter, Daena Kei
On 6/26/2015 at 1445 in 894/136, a thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following a routine test where the battery is activated. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another containment box within the same room; initial indications are that the battery package ruptured after it went into thermal runaway which led to the operator receiving bruising to the palm of the hand from the pressure of the expulsion. The operator was wearing the prescribed PPE, which was safety glassesmore » and a high temperature glove on the hand that was holding the battery.« less
F-16XL Ship #1 in flight - used for laminar airflow studies
NASA Technical Reports Server (NTRS)
1992-01-01
One of two F-16XL prototype aircraft, on loan from the Air Force, was used by NASA's Dryden Flight Research Center, Edwards, California, in a program to investigate laminar flow technology and help improve the flow of air over an aircraft's wing at sustained supersonic speeds. A small, perforated titanium wing glove with a turbo compressor was tested on the F-16XL to determine if air suction can remove a small part of the boundary-layer air flowing over the wing and thereby achieve laminar (smooth) flow over a portion of the wing. The flight research program on ship #1 ended in 1996. It was then conducted with NASA's two-seat F-16XL, ship #2 employing a larger glove.
Magnetic Field Effect in Conjugated Molecules-Based Devices
2017-10-23
triplet annihilation process (TTA) process in charge- balanced polymer light emitting diode (PLED) containing a super yellow poly-(phenylene vinylene...current density. Our results demonstrate a clear correlation between TTA process and current density as well as temperature in charge- balanced SY-PPV...dimethyl sulfoxide (DMSO) (7:3, v/v) at 60 °C for 12 h inside the nitrogen -filled glove box. The perovskite films were spin-cast by a consecutive two-step
Mir 21 crew portrait in Base Block and Priroda
1996-03-01
NM21-395-024 (March 1996) --- Posed near a microgravity glove box on the Priroda Module aboard Russias Mir Space Station are the Mir-21 crew members. From the left are astronaut Shannon W. Lucid, cosmonaut guest researcher; Yuriy V. Usachov, flight engineer; and Yuriy I. Onufriyenko, commander. Lucid went on to spend a total of 188 consecutive days in space before returning to Earth with the STS-79 crew.
1995-05-15
cooled to room temperature. Titanium isopropoxide and zirconium n-propoxide were then added (inside a glove box) to levels that correspond to the...ously patterned with a 200-nm-thick evaporated platinum film. In addition to the platinum there was a 40-nm titanium adhesion layer between the...an etch composed of buffered HF, HC1 and H20 [6]. By using a photoresist lift-off process, the top titanium -gold layer is formed, which provides the
ETR BUILDING, TRA642, INTERIOR. BASEMENT. CAMERA FACES SOUTH AND LOOKS ...
ETR BUILDING, TRA-642, INTERIOR. BASEMENT. CAMERA FACES SOUTH AND LOOKS AT DOOR TO M-3 CUBICLE. CUBICLE WALLS ARE MADE OF LEAD SHIELDING BRICKS. VALVE HANDLES AND STEMS PERTAIN TO SAMPLING. METAL SHIELDING DOOR. NOTE GLOVE BOX TO RIGHT OF CUBICLE DOOR. INL NEGATIVE NO. HD-46-21-3. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Anthropomorphic Telemanipulation System in Terminus Control Mode
NASA Technical Reports Server (NTRS)
Jau, Bruno M.; Lewis, M. Anthony; Bejczy, Antal K.
1994-01-01
This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.
2003-01-22
One of the first materials science experiments on the International Space Station -- the Solidification Using a Baffle in Sealed Ampoules (SUBSA) -- will be conducted during Expedition Five inside the Microgravity Science Glovebox. The glovebox is the first dedicated facility delivered to the Station for microgravity physical science research, and this experiment will be the first one operated inside the glovebox. The glovebox's sealed work environment makes it an ideal place for the furnace that will be used to melt semiconductor crystals. Astronauts can change out samples and manipulate the experiment by inserting their hands into a pair of gloves that reach inside the sealed box. Dr. Aleksandar Ostrogorsky, a materials scientist from the Rensselaer Polytechnic Institute, Troy, N.Y., and the principal investigator for the SUBSA experiment, uses the gloves to examine an ampoule like the ones used for his experiment inside the glovebox's work area. The Microgravity Science Glovebox and the SUBSA experiment are managed by NASA's Marshall Space Flight Center in Huntsville, Ala.
VIEW OF THE INTERIOR OF BUILDING 774, THE ORIGINAL LIQUID ...
VIEW OF THE INTERIOR OF BUILDING 774, THE ORIGINAL LIQUID PROCESS WASTEWATER TREATMENT FACILITY. THE PHOTOGRAPH SHOWS STORAGE TANKS AND ASSOCIATED PLUTONIUM-CONTAMINATED SOLUTIONS. THE GLOVE BOX IS USED BY OPERATORS TO MANUALLY OPERATE PUMPS AND VALVES THAT REQUIRE PERIODIC ADJUSTMENT. OTHER VALVES IN THE ROOM WERE INFREQUENTLY ADJUSTED, AND ARE SEALED IN PLASTIC WRAP - Rocky Flats Plant, Waste Treatment Facility, Adjacent to bldg 771C, in northern portion of protected area, Golden, Jefferson County, CO
Continuous microwave regeneration apparatus for absorption media
Smith, Douglas D.
1999-01-01
A method and apparatus for continuously drying and regenerating ceramic beads for use in process gas moisture drying operations such as glove boxes. A microwave energy source is coupled to a process chamber to internally heat the ceramic beads and vaporize moisture contained therein. In a preferred embodiment, the moisture laden ceramic beads are conveyed toward the microwave source by a screw mechanism. The regenerated beads flow down outside of the screw mechanism and are available to absorb additional moisture.
Asymmetric Electrochemical Capacitors - Stretching the Limits of Aqueous Electrolytes
2011-07-01
controlled atmosphere (no need for a dry room or glove box), simplifying the fabrication and packaging process. The use of a faradaic material with a fi...than the thin (25 μ m) aluminum foil current collectors used in nonaqueous EDLCs. The corrosion of these current collectors must also be minimized...valid OMB control number. 1. REPORT DATE JUL 2011 2. REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011 4. TITLE AND SUBTITLE Asymmetric
Pierson, Jason; Fernández, José Jesús; Bos, Erik; Amini, Shoaib; Gnaegi, Helmut; Vos, Matthijn; Bel, Bennie; Adolfsen, Freek; Carrascosa, José L; Peters, Peter J
2010-02-01
Cryo-electron tomography of vitreous cryo-sections is the most suitable method for exploring the 3D organization of biological samples that are too large to be imaged in an intact state. Producing good quality vitreous cryo-sections, however, is challenging. Here, we focused on the major obstacles to success: contamination in and around the microtome, and attachment of the ribbon of sections to an electron microscopic grid support film. The conventional method for attaching sections to the grid has involved mechanical force generated by a crude stamping or pressing device, but this disrupts the integrity of vitreous cryo-sections. Furthermore, attachment is poor, and parts of the ribbon of sections are often far from the support film. This results in specimen instability during image acquisition and subsequent difficulty with aligning projection images. Here, we have implemented a protective glove box surrounding the cryo-ultramicrotome that reduces the humidity around and within the microtome during sectioning. We also introduce a novel way to attach vitreous cryo-sections to an EM grid support film using electrostatic charging. The ribbon of vitreous cryo-sections remains in place during transfer and storage and is devoid of stamping related artefacts. We illustrate these improvements by exploring the structure of putative cellular 80S ribosomes within 50nm, vitreous cryo-sections of Saccharomyces cerevisiae.
Chau, Q; Bruguier, P
2007-01-01
In nuclear facilities, some activities such as reprocessing, recycling and production of bare fuel rods expose the workers to mixed neutron-photon fields. For several workplaces, particularly in glove boxes, some workers expose their hands to mixed fields. The mastery of the photon extremity dosimetry is relatively good, whereas the neutron dosimetry still raises difficulties. In this context, the Institute for Radiological Protection and Nuclear Safety (IRSN) has proposed a study on a passive neutron extremity dosemeter based on chemically etched CR-39 (PADC: polyallyldiglycolcarbonate), named PN-3, already used in routine practice for whole body dosimetry. This dosemeter is a chip of plastic sensitive to recoil protons. The chemical etching process amplifies the size of the impact. The reading system for tracks counting is composed of a microscope, a video camera and an image analyser. This system is combined with the dose evaluation algorithm. The performance of the dosemeter PN-3 has been largely studied and proved by several laboratories in terms of passive individual neutron dosemeter which is used in routine production by different companies. This study focuses on the sensitivity of the extremity dosemeter, as well as its performance in the function of the level of the neutron energy. The dosemeter was exposed to monoenergetic neutron fields in laboratory conditions and to mixed fields in glove boxes at workplaces.
Hazard Analysis for Building 34 Vacuum Glove Box Assembly
NASA Technical Reports Server (NTRS)
Meginnis, Ian
2014-01-01
One of the characteristics of an effective safety program is the recognition and control of hazards before mishaps or failures occur. Conducting potentially hazardous tests necessitates a thorough hazard analysis in order to prevent injury to personnel, and to prevent damage to facilities and equipment. The primary purpose of this hazard analysis is to define and address the potential hazards and controls associated with the Building 34 Vacuum Glove Box Assembly, and to provide the applicable team of personnel with the documented results. It is imperative that each member of the team be familiar with the hazards and controls associated with his/her particular tasks, assignments and activities while interfacing with facility test systems, equipment and hardware. In fulfillment of the stated purposes, the goal of this hazard analysis is to identify all hazards that have the potential to harm personnel, damage the facility or its test systems or equipment, test articles, Government or personal property, or the environment. This analysis may also assess the significance and risk, when applicable, of lost test objectives when substantial monetary value is involved. The hazards, causes, controls, verifications, and risk assessment codes have been documented on the hazard analysis work sheets in Appendix A of this document. The preparation and development of this report is in accordance with JPR 1700.1, "JSC Safety and Health Handbook" and JSC 17773 Rev D "Instructions for Preparation of Hazard Analysis for JSC Ground Operations".
Ultracold Field Gradient Magnetometry and Transport to Study Correlated Topological Phases
2016-10-01
glove box. Note that in Fig. 1(b) baking blankets are attached to the MBE, but are removed during normal operation of the system. The manipulator...Note that in Fig. 1(b) baking blankets are attached to the MBE, but are removed during normal operation of the system. The manipulator arms are
2012-09-18
STS083-302-002 (4-8 April 1997) --- At the MidDeck Glove Box (MGBX), astronaut Donald A. Thomas, mission specialist, prepares to conduct the Internal Flows in Free Drops (IFFD) experiment. The IFFD is meant to study drops of several liquids, including water, water/glycerin and silicon oil. Flows within the drops and shape and stability are studied under varying acoustic pressure. The MGBX is the overall facility that holds experiments on materials that are not approved for study in the open Spacelab environment.
A perspective of laminar-flow control. [aircraft energy efficiency program
NASA Technical Reports Server (NTRS)
Braslow, A. L.; Muraca, R. J.
1978-01-01
A historical review of the development of laminar flow control technology is presented with reference to active laminar boundary-layer control through suction, the use of multiple suction slots, wind-tunnel tests, continuous suction, and spanwise contamination. The ACEE laminar flow control program is outlined noting the development of three-dimensional boundary-layer codes, cruise-noise prediction techniques, airfoil development, and leading-edge region cleaning. Attention is given to glove flight tests and the fabrication and testing of wing box designs.
Prototyping phase of the high heat flux scraper element of Wendelstein 7-X
Boscary, Jean; Greuner, Henri; Ehrke, G.; ...
2016-03-24
The water-cooled high heat flux scraper element aims to reduce excessive heat loads on the target element ends of the actively cooled divertor of Wendelstein 7-X. Its purpose is to intercept some of the plasma fluxes both upstream and downstream before they reach the divertor surface. The scraper element has 24 identical plasma facing components (PFCs) divided into 6 modules. One module has 4 PFCs hydraulically connected in series by 2 water boxes. A PFC, 247 mm long and 28 mm wide, has 13 monoblocks made of CFC NB31 bonded by hot isostatic pressing onto a CuCrZr cooling tube equippedmore » with a copper twisted tape. 4 full-scale prototypes of PFCs have been successfully tested in the GLADIS facility up to 20 MW/m 2. The difference observed between measured and calculated surface temperatures is probably due to the inhomogeneity of CFC properties. The design of the water box prototypes has been detailed to allow the junction between the cooling pipe of the PFCs and the water boxes by internal orbital welding. In conclusion, the prototypes are presently under fabrication.« less
Chemical Resistance of Disposable Nitrile Gloves Exposed to Simulated Movement
Phalen, Robert N.; Wong, Weng Kee
2012-01-01
Large discrepancies between laboratory permeation testing and field exposures have been reported, with indications that hand movement could account for a portion of these differences. This study evaluated the influence of simulated movement on chemical permeation of 30 different disposable nitrile glove products. Products were investigated out-of-box and with exposure to simulated whole-glove movement. Permeation testing was conducted using ethanol as a surrogate test chemical. A previously designed pneumatic system was used to simulate hand movement. No movement and movement tests were matched-paired to control for environmental conditions, as were statistical analyses. Permeation data were collected for a 30-min exposure period or until a breakthrough time (BT) and steady-state permeation rate (SSPR) could be determined. A third parameter, area under the curve at 30 min (AUC-30), was used to estimate potential worker exposure. With movement, a significant decrease in BT (p ≤ 0.05), ranging from 6–33%, was observed for 28 products. The average decrease in BT was 18% (p ≤ 0.001). With movement, a significant increase in SSPR (p ≤ 0.05), ranging from 1–78%, was observed with 25 products. The average increase in SSPR was 18% (p ≤ 0.001). Significant increases in AUC-30 (p ≤ 0.05), ranging from 23–277%, were also observed for all products where it could be calculated. On average, there was a 58% increase (p ≤ 0.001). The overall effect of movement on permeation through disposable nitrile gloves was significant. Simulated movement significantly shortened the BT, increased the SSPR, and increased the cumulative 30-min exposure up to three times. Product variability also accounted for large differences, up to 40 times, in permeation and cumulative exposure. Glove selection must take these factors into account. It cannot be assumed that all products will perform in a similar manner. PMID:23009187
Teacher's Guide to Animal Camouflage: The MATCH Box Project; Prototype Edition.
ERIC Educational Resources Information Center
Standring, Gillian; Bernath, Robert
The Materials and Activities for Teachers and Children (MATCH Box) project was developed in 1965 to provide for the relatively intensive treatment of a subject over a short period through materials geared to the elementary school level. Each MATCH Box contains materials, equipment, and activities that work together to foster the teaching/learning…
Next Generation Life Support Project Status
NASA Technical Reports Server (NTRS)
Barta, Daniel J.; Chullen, Cinda; Vega, Leticia; Cox, Marlon R.; Aitchison, Lindsay T.; Lange, Kevin E.; Pensinger, Stuart J.; Meyer, Caitlin E.; Flynn, Michael; Jackson, W. Andrew;
2014-01-01
Next Generation Life Support (NGLS) is one of over twenty technology development projects sponsored by NASA's Game Changing Development Program. The NGLS Project develops selected life support technologies needed for humans to live and work productively in space, with focus on technologies for future use in spacecraft cabin and space suit applications. Over the last three years, NGLS had five main project elements: Variable Oxygen Regulator (VOR), Rapid Cycle Amine (RCA) swing bed, High Performance (HP) Extravehicular Activity (EVA) Glove, Alternative Water Processor (AWP) and Series-Bosch Carbon Dioxide Reduction. The RCA swing bed, VOR and HP EVA Glove tasks are directed at key technology needs for the Portable Life Support System (PLSS) and pressure garment for an Advanced Extravehicular Mobility Unit (EMU). Focus is on prototyping and integrated testing in cooperation with the Advanced Exploration Systems (AES) Advanced EVA Project. The HP EVA Glove Element, new this fiscal year, includes the generation of requirements and standards to guide development and evaluation of new glove designs. The AWP and Bosch efforts focus on regenerative technologies to further close spacecraft cabin atmosphere revitalization and water recovery loops and to meet technology maturation milestones defined in NASA's Space Technology Roadmaps. These activities are aimed at increasing affordability, reliability, and vehicle self-sufficiency while decreasing mass and mission cost, supporting a capability-driven architecture for extending human presence beyond low-Earth orbit, along a human path toward Mars. This paper provides a status of current technology development activities with a brief overview of future plans.
Bi-Modal Model for Neutron Emissions from PuO{sub 2} and MOX Holdup
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menlove, Howard; Lafleur, Adrienne
2015-07-01
The measurement of uranium and plutonium holdup in plants during process activity and for decommissioning is important for nuclear safeguards and material control. The amount of plutonium and uranium holdup in glove-boxes, pipes, ducts, and other containers has been measured for several decades using both neutron and gamma-ray techniques. For the larger containers such as hot cells and glove-boxes that contain processing equipment, the gamma-ray techniques are limited by self-shielding in the sample as well as gamma absorption in the equipment and associated shielding. The neutron emission is more penetrating and has been used extensively to measure the holdup formore » the large facilities such as the MOX processing and fabrication facilities in Japan and Europe. In some case the totals neutron emission rates are used to determine the holdup mass and in other cases the coincidence rates are used such as at the PFPF MOX fabrication plant in Japan. The neutron emission from plutonium and MOX has 3 primary source terms: 1) Spontaneous fission (SF) from the plutonium isotopes, 2) The (α,n) reactions from the plutonium alpha particle emission reacting with the oxygen and other impurities, and 3) Neutron multiplication (M) in the plutonium and uranium as a result of neutrons created by the first two sources. The spontaneous fission yield per gram is independent of thickness, whereas, the above sources 2) and 3) are very dependent on the thickness of the deposit. As the effective thickness of the deposit becomes thin relative to the alpha particle range, the (α,n) reactions and neutrons from multiplication (M) approach zero. In any glove-box, there will always be two primary modes of holdup accumulation, namely direct powder contact and non-contact by air dispersal. These regimes correspond to surfaces in the glove-box that have come into direct contact with the process MOX powder versus surface areas that have not had direct contact with the powder. The air dispersal of PuO{sub 2} particles has been studied for several decades by health physicists, because the primary health hazard of plutonium is breathing the airborne particles. The air dispersal mechanism results from the smaller particles in the top layer of powder that are lifted into the air by the electrostatic charge buildup from the alpha decay process, and the air convection carries the particles to new more distant locations. If there is open plutonium powder in a glove-box, the surfaces at more distant locations will become contaminated over time. The range of an alpha particle in a solid or powder is a function of the particle energy, the material density, and the atomic number A of the material. The average energy of a plutonium alpha particle is ∼5.2 MeV and the range in air is ∼37 mm. The range in other materials can be estimated via the Bragg-Kleenman equation. For plutonium, A is 94, and the typical density for a single particle is ∼11.5 g/cm{sup 3}, but for a powder, the density would be less because of the air packing fraction. The significance of the small diameter is that the range of the alpha particle is ∼50 μm for powder density 2.5 and significantly less for a single particle with density 11.5, so the thin deposit of separate small particles will have a greatly reduced (α,n) yield. The average alpha transit length to the surface in the isolated MOX particle would be < 2.5 μm; whereas, the range of the alpha particle is much longer. Thus, most of the alpha particles would escape from the MOX particle and be absorbed by the walls and air. The air dispersal particles will have access to a large surface area that includes the walls, whereas, the powder contact surface area will be orders of magnitude smaller. Thus, the vast majority of the glove-box surface area does not produce the full (α,n) reaction neutron yield, even from the O{sub 2} in the PuO{sub 2} as well as any impurity contamination such as H{sub 2}O. To obtain a more quantitative estimate of the neutron (α,n) yields as a function of holdup deposit thickness, we have used MCNPX calculations to estimate the absorption of alpha particles in PuO{sub 2} holdup deposits. The powder thickness was varied from 0.1 μm to 5000 μm and the alpha particle escape probability was calculated. As would be expected, as the thickness approaches zero, the escape probability approaches 1.0, and as the thickness gets much greater than the alpha particle range (∼50 μm), the escape probability becomes small. Typically, the neutron holdup calibration measurement are performed using sealed containers of thick MOX that has all 3 sources of neutrons [SF, (α,n), and M], and no significant impurities. Thus, the calibration counting rates need to include corrections for M and (α,n) yields that are different for the holdup compared with the calibration samples. If totals neutron counting is used for the holdup measurements, the variability of the (α,n) term needs to be considered.« less
[Development of an electronic device to organize medications and promote treatment adherence].
Vieira, Liliana Batista; Ramos, Celso de Ávila; Castello, Matheus de Barros; Nascimento, Lorenzo Couto do
2016-04-01
This article describes the development of an electronic prototype to organize medications - the Electronic System for Personal and Controlled Use of Medications (Sistema Eletrônico de Uso Personalizado e Controlado de Medicamentos, SUPERMED). The prototype includes a drawer containing 1 month's supply of medicines, sound and visual medication timers, and a memory card for recording the times when the box was opened/closed (scheduled and unscheduled). This information is later transferred to a computer. Evolutionary prototyping was used to develop SUPERMED with the Arduino platform and C programming. To read alarm and box opening/closing data, software was developed in Java. Once the alarms are programmed (ideally by a health care professional), no additional adjustments are required by the patient. The prototype was tested during 31 days by the developers, with satisfactory functioning. The system seems adequate to organize medications and facilitate adherence to treatment. New studies will be carried out to validate and improve the prototype.
Teacher's Guide to Paddle-to-the-Sea: The MATCH Box Project; Prototype Edition.
ERIC Educational Resources Information Center
Bever, Buz; Kresse, Frederick H.
The Materials and Activities for Teachers and Children (MATCH Box) project provides for a two-week intensive treatment of a subject on the elementary school level. Each MATCH Box contains materials, equipment and activities that work together to foster the teaching/learning of the particular subject matter. PADDLE-TO-THE-SEA is a social studies…
Teacher's Guide to the Algonquins: The MATCH Box Project; Prototype Edition.
ERIC Educational Resources Information Center
Butler, Eva; And Others
What better way is there to learn about something than to hold it, examine it, and take it apart? The Match Box Project (Materials and Activities for Teachers and Children) loans to schools a series of boxes which contain materials, equipment, supplies, and activities designed as a unit to foster the teaching/learning of specific subjects at the…
Dissolved oxygen concentration in the medium during cell culture: Defects and improvements.
Zhang, Kuan; Zhao, Tong; Huang, Xin; He, Yunlin; Zhou, Yanzhao; Wu, Liying; Wu, Kuiwu; Fan, Ming; Zhu, Lingling
2016-03-01
In vitro cell culture has provided a useful model to study the effects of oxygen on cellular behavior. However, it remains unknown whether the in vitro operations themselves affect the medium oxygen levels and the living states of cells. In addition, a prevailing controversy is whether reactive oxygen species (ROS) production is induced by continuous hypoxia or reoxygenation. In this study, we have measured the effects of different types of cell culture containers and the oxygen environment where medium replacement takes place on the actual oxygen tension in the medium. We found that the deviations of oxygen concentrations in the medium are much greater in 25-cm(2) flasks than in 24-well plates and 35-mm dishes. The dissolved oxygen concentrations in the medium were increased after medium replacement in normoxia, but remained unchanged in glove boxes in which the oxygen tension remained at a low level (11.4, 5.7, and 0.5% O2 ). We also found that medium replacement in normoxia increased the number of ROS-positive cells and reduced the cell viability; meanwhile, medium replacement in a glove box did not produce the above effects. Therefore, we conclude that the use of 25-cm(2) flasks should be avoided and demonstrate that continuous hypoxia does not produce ROS, whereas the reoxygenation that occurs during the harvesting of cells leads to ROS and induces cell death. © 2015 International Federation for Cell Biology.
Müllers, Erik; Uhlig, Tobias; Stirnnagel, Kristin; Fiebig, Uwe; Zentgraf, Hanswalter; Lindemann, Dirk
2011-02-01
Prototype foamy virus (PFV) Gag lacks the characteristic orthoretroviral Cys-His motifs that are essential for various steps of the orthoretroviral replication cycle, such as RNA packaging, reverse transcription, infectivity, integration, and viral assembly. Instead, it contains three glycine-arginine-rich boxes (GR boxes) in its C terminus that putatively represent a functional equivalent. We used a four-plasmid replication-deficient PFV vector system, with uncoupled RNA genome packaging and structural protein translation, to analyze the effects of deletion and various substitution mutations within each GR box on particle release, particle-associated protein composition, RNA packaging, DNA content, infectivity, particle morphology, and intracellular localization. The degree of viral particle release by all mutants was similar to that of the wild type. Only minimal effects on Pol encapsidation, exogenous reverse transcriptase (RT) activity, and genomic viral RNA packaging were observed. In contrast, particle-associated DNA content and infectivity were drastically reduced for all deletion mutants and were undetectable for all alanine substitution mutants. Furthermore, GR box I mutants had significant changes in particle morphology, and GR box II mutants lacked the typical nuclear localization pattern of PFV Gag. Finally, it could be shown that GR boxes I and III, but not GR box II, can functionally complement each other. It therefore appears that, similar to the orthoretroviral Cys-His motifs, the PFV Gag GR boxes are important for RNA encapsidation, genome reverse transcription, and virion infectivity as well as for particle morphogenesis.
Preparing cytotoxic agents in an isolator.
Favier, M; Hansel, S; Bressolle, F
1993-11-01
The design of an isolator and its use by an oncology satellite pharmacy for preparing cytotoxic drugs are described. The isolator (Iso Concept, Boulogne, France) is a totally enclosed ventilated biological-safety cabinet of class III polyvinyl chloride (PVC) with positive air pressure, a half-suit with a rotating seal, and attached neoprene gloves. There are three work-stations, one for the half-suit and two along one side of the isolator. The ventilation and air filtration system consists of one entry pipe with a full ventilation-filtration box fitted with one prefilter, one blower, one ball valve, one high-efficiency particulate air (HEPA) filter, one airtight nipple connected to an automatic sterilizer, alarms, and one exhaust pipe protected by a HEPA filter. The air lock consists of a rigid, transparent Plexiglas pass-through. The chamber is sterilized with heated compressed air mixed with 3.5% peracetic acid. Maintenance includes regular changing of gloves and HEPA filters; checking of the integrity of the PVC, half-suit, and gloves; and washing and decontamination procedures. Preparation of cytotoxics is planned in advance with prescription data and manufacturing sheets. In the half-suit, a pharmacy technician reads the label, supervises preparation of the sterile admixture, and writes a label. The operators on the side of the unit read the manufacturing sheet and prepare the dose identified by the label.(ABSTRACT TRUNCATED AT 250 WORDS)
MGBX - PS Crouch with experiment module
2016-08-12
STS083-346-024 (4-8 April 1997) --- Payload specialist Roger K. Crouch performs the activation for the Mid Deck Glove Box (MGBX). Made to accommodate a variety of hardware and materials testing, the facility offers physical isolation and a negative air pressure environment so that items that are not suitable for handling in the open Spacelab can be protected. One experiment that was performed on STS-83 is the Internal Flows in a Free Drop (IFFD), an experiment that investigates rotation and position control of drops by varying acoustic pressures.
The Astronaut Glove Challenge: Big Innovation from a (Very) Small Team
NASA Technical Reports Server (NTRS)
Homer, Peter
2008-01-01
Many measurements were taken by test engineers from Hamilton Sundstrand, the prime contractor for the current EVA suit. Because the raw measurements needed to be converted to torques and combined into a final score, it was impossible to keep track of who was ahead in this phase. The final comfort and dexterity test was performed in a depressurized glove box to simulate real on-orbit conditions. Each competitor was required to exercise the glove through a defined set of finger, thumb, and wrist motions without any sign of abrasion or bruising of the competitor's hand. I learned a lot about arm fatigue! This was a pass-fail event, and both of the remaining competitors came through intact. After taking what seemed like an eternity to tally the final scores, the judges announced that I had won the competition. My glove was the only one to have achieved lower finger-bending torques than the Phase VI glove. Looking back, I see three sources of the success of this project that I believe also operate in other programs where small teams have broken new ground in aerospace technologies. These are awareness, failure, and trust. By remaining aware of the big picture, continuously asking myself, "Am I converging on a solution?" and "Am I converging fast enough?" I was able to see that my original design was not going to succeed, leading to the decision to start over. I was also aware that, had I lingered over this choice or taken time to analyze it, I would not have been ready on the first day of competition. Failure forced me to look outside conventional thinking and opened the door to innovation. Choosing to make incremental failures enabled me to rapidly climb the learning curve. Trusting my "gut" feelings-which are really an internalized accumulation of experiences-and my newly acquired skills allowed me to devise new technologies rapidly and complete both gloves just in time. Awareness, failure, and trust are intertwined: failure provides experiences that inform awareness and provide decision-making opportunities that build trust among team members and managers while opening minds to new pathways for development. All three are necessary for teams-large or small-to achieve big innovation.
Spring roll dielectric elastomer actuators for a portable force feedback glove
NASA Astrophysics Data System (ADS)
Zhang, Rui; Lochmatter, Patrick; Kunz, Andreas; Kovacs, Gabor
2006-03-01
Miniature spring roll dielectric elastomer actuators for a novel kinematic-free force feedback concept were manufactured and experimentally characterized. The actuators exhibited a maximum blocking force of 7.2 N and a displacement of 5 mm. The theoretical considerations based on the material's incompressibility were discussed in order to estimate the actuator behavior under blocked-strain activation and free-strain activation. One prototype was built for the demonstration of the proposed force feedback concept.
Martell, C.J.; Dahlby, J.W.; Gallimore, B.F.; Comer, B.E.; Stone, W.A.; Carlson, D.O.
1993-04-27
An enclosure is described, similar to a glove box, for isolating materials from the atmosphere, yet allowing a technician to manipulate the materials and also apparatus which is located inside the enclosure. A portion of a wall of the enclosure is comprised of at least one flexible curtain. An opening defined by a frame is provided for the technician to insert his hands and forearms into the enclosure. The frame is movable in one plane, so that the technician has access to substantially all of the working interior of the enclosure. As the frame is moved by the technician, while he accomplishes work inside the enclosure, the curtain moves such that the only opening through the enclosure wall is the frame. In a preferred embodiment, where a negative pressure is maintained inside the enclosure, the frame is comprised of airfoils so that turbulence is reduced, thereby enhancing material retention within the box.
Final Radiological Assessment of External Exposure for CLEAR-Line Americium Recovery Operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Adam C.; Belooussova, Olga N.; Hetrick, Lucas Duane
2014-11-12
Los Alamos National Laboratory is currently planning to implement an americium recovery program. The americium, ordinarily isotopically pure 241Am, would be extracted from existing Pu materials, converted to an oxide and shipped to support fabrication of americium oxide-beryllium neutron sources. These operations would occur in the currently proposed Chloride Extraction and Actinide Recovery (CLEAR) line of glove boxes. This glove box line would be collocated with the currently-operational Experimental Chloride Extraction Line (EXCEL). The focus of this document is to provide an in-depth assessment of the currently planned radiation protection measures and to determine whether or not further design workmore » is required to satisfy design-goal and ALARA requirements. Further, this document presents a history of americium recovery operations in the Department of Energy and high-level descriptions of the CLEAR line operations to provide a basis of comparison. Under the working assumptions adopted by this study, it was found that the evaluated design appears to mitigate doses to a level that satisfies the ALARA-in-design requirements of 10 CFR 835 as implemented by the Los Alamos National Laboratory procedure P121. The analyses indicate that extremity doses would also meet design requirements. Dose-rate calculations were performed using the radiation transport code MCNP5 and doses were estimated using a time-motion study developed in consort with the subject matter expert. A copy of this report and all supporting documentation are located on the Radiological Engineering server at Y:\\Rad Engineering\\2013 PROJECTS\\TA-55 Clear Line.« less
Development of first ever scanning probe microscopy capabilities for plutonium
NASA Astrophysics Data System (ADS)
Beaux, Miles F.; Cordoba, Miguel Santiago; Zocco, Adam T.; Vodnik, Douglas R.; Ramos, Michael; Richmond, Scott; Moore, David P.; Venhaus, Thomas J.; Joyce, Stephen A.; Usov, Igor O.
2017-04-01
Scanning probe microscopy capabilities have been developed for plutonium and its derivative compounds. Specifically, a scanning tunneling microscope and an atomic force microscope housed in an ultra-high vacuum system and an inert atmosphere glove box, respectively, were prepared for the introduction of small non-dispersible δ-Pu coupons. Experimental details, procedures, and preliminary imaging of δ-Pu coupons are presented to demonstrate the functionality of these new capabilities. These first of a kind capabilities for plutonium represent a significant step forward in the ability to characterize and understand plutonium surfaces with high spatial resolution.
Development of first ever scanning probe microscopy capabilities for plutonium
Beaux, Miles F.; Cordoba, Miguel Santiago; Zocco, Adam T.; ...
2017-04-01
Scanning probe microscopy capabilities have been developed for plutonium and its derivative compounds. Specifically, a scanning tunneling microscope and an atomic force microscope housed in an ultra-high vacuum system and an inert atmosphere glove box, respectively, were prepared for the introduction of small non-dispersible δ-Pu coupons. Experimental details, procedures, and preliminary imaging of δ-Pu coupons are presented to demonstrate the functionality of these new capabilities. In conclusion, these first of a kind capabilities for plutonium represent a significant step forward in the ability to characterize and understand plutonium surfaces with high spatial resolution.
Double gloving to reduce surgical cross-infection.
Tanner, J; Parkinson, H
2002-01-01
The invasive nature of surgery, with its increased exposure to blood, means that during surgery there is a high risk of transfer of pathogens. Pathogens can be transferred through contact between surgical patients and the surgical team, resulting in post-operative or blood borne infections in patients or blood borne infections in the surgical team. Both patients and the surgical team need to be protected from this risk. This risk can be reduced by implementing protective barriers such as wearing surgical gloves. Wearing two pairs of surgical gloves, as opposed to one pair, is considered to provide an additional barrier and further reduce the risk of contamination. The primary objective of this review was to determine if double gloving (wearing two pairs of gloves), rather than single gloving, reduces the number of post-operative or blood borne infections in surgical patients or blood borne infections in the surgical team. The secondary objective of this review was to determine if double gloving, rather than single gloving, reduces the number of perforations to the innermost pair of surgical gloves. The innermost gloves (next to skin) compared with the outermost gloves are considered to be the last barrier between the patient and the surgical team. The reviewers searched the Cochrane Wounds Group Specialised Trials Register, MEDLINE, CINAHL, EMBASE and the Cochrane Controlled Trials Register. Glove manufacturing companies and professional organisations were also contacted. Randomised controlled trials involving: single gloving, double gloving, glove liners or coloured puncture indicator systems. Both reviewers independently assessed the relevance and quality of each trial. Trials to be included were cross checked and authenticated by both reviewers. Data was extracted by one reviewer and cross checked for accuracy by the second reviewer. Two trials were found which addressed the primary outcome. A total of 18 randomised controlled trials which measured glove perforations were identified and included in the review. DOUBLE GLOVING (wearing two pairs of latex gloves). Nine trials compared single latex gloves versus double latex gloves. These found no difference in the number of perforations between the single latex gloves and the outermost pair of the double latex gloves, but the number of perforations to the double latex-innermost glove was significantly reduced when two pairs of latex gloves were worn. ORTHOPAEDIC GLOVES (thicker than standard latex gloves). One trial compared single latex orthopaedic gloves with double latex gloves. This showed there was no difference in the number of perforations to the innermost gloves when wearing double latex gloves compared with a single pair of latex orthopaedic gloves. INDICATOR GLOVES (coloured latex gloves worn underneath latex gloves). Three trials compared double latex gloves versus double latex indicator gloves. These trials showed similar numbers of perforations to both the innermost and the outermost gloves for both gloving groups. Perforations to the outermost gloves were detected more easily when double latex indicator gloves were worn. Wearing double latex indicator gloves did not increase the detection of perforations to the innermost gloves. GLOVE LINERS (an insert worn between two pairs of latex gloves). Two trials compared double latex gloves versus double latex gloves with liners. These trials showed a significant reduction in the number of perforations to the innermost glove when a glove liner was worn between two pairs of latex gloves. CLOTH GLOVES (cloth gloves worn on top of latex gloves). Two trials compared double latex gloves versus latex inner with cloth outer gloves. These trials showed that wearing a cloth outer glove significantly reduced the number of perforations to the innermost latex glove. STEEL WEAVE GLOVES (steel weave gloves worn on top of latex gloves). One trial compared double latex gloves versus latex inner with steel weave outer gloves. This trial showed no reduction in the number of perforations to the innermost glove when wearing a steel weave outer glove. Wearing two pairs of latex gloves significantly reduces the number of perforations to the innermost glove. This evidence comes from trials undertaken in 'low risk' surgical specialties, that is specialties which did not include orthopaedic joint surgery. Wearing two pairs of latex gloves does not cause the glove wearer to sustain more perforations to their outermost glove. Wearing double latex indicator gloves enables the glove wearer to detect perforations to the outermost glove more easily than when wearing double latex gloves. However wearing a double latex indicator system will not assist with the detection of perforations to the innermost glove, nor reduce the number of perforations to either the outermost or the innermost glove. Wearing a glove liner between two pairs of latex gloves to undertake joint replacement surgery significantly reduces the number of perforations to the innermost glove compared with double latex gloves only. Wearing cloth outer gloves to undertake joint replacement surgery significantly reduces the number of perforations to the innermost glove compared with wearing double latex gloves. Wearing steel weave outer gloves to undertake joint replacement surgery does not reduce the number of perforations to innermost gloves compared with double latex gloves.
2012-03-22
Fabric 3.85% Polypropylene (PP) (Class 5 plastics, soda cups, yogurt boxes, syrup bottles, prescription bottles) 1.32% Yard waste 5.67% PVC (Class 3...plastics, milk jugs) 1.23% Cardboard 31.33% Polypropylene (PP) (Class 5 plastics, soda cups, yogurt boxes, syrup bottles, prescription bottles) 0.62
Double gloving to reduce surgical cross-infection.
Tanner, J; Parkinson, H
2006-07-19
The invasive nature of surgery, with its increased exposure to blood, means that during surgery there is a high risk of transfer of pathogens. Pathogens can be transferred through contact between surgical patients and the surgical team, resulting in post-operative or blood borne infections in patients or blood borne infections in the surgical team. Both patients and the surgical team need to be protected from this risk. This risk can be reduced by implementing protective barriers such as wearing surgical gloves. Wearing two pairs of surgical gloves, triple gloves, glove liners or cloth outer gloves, as opposed to one pair, is considered to provide an additional barrier and further reduce the risk of contamination. The primary objective of this review was to determine if additional glove protection reduces the number of surgical site or blood borne infections in patients or the surgical team. The secondary objective was to determine if additional glove protection reduces the number of perforations to the innermost pair of surgical gloves. The innermost gloves (next to skin) compared with the outermost gloves are considered to be the last barrier between the patient and the surgical team. We searched the Cochrane Wounds Group Specialised Register (January 2006), and the Cochrane Central Register of Controlled Trials (CENTRAL)(The Cochrane Library Issue 4, 2005). We also contacted glove manufacturing companies and professional organisations. Randomised controlled trials involving: single gloving, double gloving, triple gloving, glove liners, knitted outer gloves, steel weave outer gloves and perforation indicator systems. Both authors independently assessed the relevance and quality of each trial. Data was extracted by one author and cross checked for accuracy by the second author. Two trials were found which addressed the primary outcome, namely, surgical site infections in patients. Both trials reported no infections. Thirty one randomised controlled trials measuring glove perforations were identified and included in the review. Fourteen trials of double gloving (wearing two pairs of surgical latex gloves) were pooled and showed that there were significantly more perforations to the single glove than the innermost of the double gloves (OR 4.10, 95% CI 3.30 to 5.09). Eight trials of indicator gloves (coloured latex gloves worn underneath latex gloves to more rapidly alert the team to perforations) showed that significantly fewer perforations were detected with single gloves compared with indicator gloves (OR 0.10, 95% CI 0.06 to 0.16) or with standard double glove compared with indicator gloves (OR 0.08, 95% CI 0.04 to 0.17). Two trials of glove liners (a glove knitted with cloth or polymers worn between two pairs of latex gloves)(OR 26.36, 95% CI 7.91 to 87.82), three trials of knitted gloves (knitted glove worn on top of latex surgical gloves)(OR 5.76, 95% CI 3.25 to 10.20) and one trial of triple gloving (three pairs of latex surgical gloves)(OR 69.41, 95% CI 3.89 to 1239.18) all compared with standard double gloves, showed there were significantly more perforations to the innermost glove of a standard double glove in all comparisons. There is no direct evidence that additional glove protection worn by the surgical team reduces surgical site infections in patients, however the review has insufficient power for this outcome. The addition of a second pair of surgical gloves significantly reduces perforations to innermost gloves. Triple gloving, knitted outer gloves and glove liners also significantly reduce perforations to the innermost glove. Perforation indicator systems results in significantly more innermost glove perforations being detected during surgery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Q; Zavarin, M; Rose, T P
Laboratory batch sorption experiments were used to investigate variations in the retardation behavior of redox-sensitive radionuclides. Water-rock compositions used during these experiments were designed to simulate subsurface conditions at the Nevada Test Site (NTS), where a suite of radionuclides were deposited as a result of underground nuclear testing. Experimental redox conditions were controlled by varying the oxygen content inside an enclosed glove box and by adding reductants into the testing solutions. Under atmospheric (oxidizing) conditions, the radionuclide distribution coefficients varied with the mineralogical composition of the sorbent and the water chemistry. Under reducing conditions, distribution coefficients showed marked increases formore » {sup 99}Tc and {sup 237}Np in devitrified tuff, but much smaller variations in alluvium, carbonate rock, and zeolitic tuff. This effect was particularly important for {sup 99}Tc, which tends to be mobile under oxidizing conditions. Unlike other redox-sensitive radionuclides, iodine sorption may decrease under reducing conditions when I{sup -} is the predominant species. Overall, sorption of U to alluvium, devitrified tuff, and zeolitic tuff under atmospheric conditions was less than in the glove-box tests. However, the mildly reducing conditions achieved here were not likely to result in substantial U(VI) reduction to U(IV). Sorption of Pu was not affected by the decreasing redox conditions achieved in this study, as the predominant sorbed Pu species in all conditions was expected to be the low-solubility and strongly sorbing Pu(OH){sub 4}. Depending on the aquifer lithology, the occurrence of reducing conditions along a groundwater flowpath could potentially contribute to the retardation of redox-sensitive radionuclides {sup 99}Tc and {sup 237}Np, which are commonly identified as long-term dose contributors in the risk assessment in various nuclear facilities.« less
NASA Astrophysics Data System (ADS)
Vanleeuw, D.; Lewis, D.; Moens, A.; Sibbens, G.; Wiss, T.
2018-05-01
Measurement of neutron cross section data is a core activity of the JRC-Directorate G for Nuclear Safety and Security in Geel. After a period of reduced activity and in line with a renewed interest for nuclear data required for GenIV reactors and waste minimization, the demand for high quality actinide targets increased. Physical vapour deposition by thermal evaporation is a key technique to prepare homogeneous thin actinide layers, but due to ageing effects the earlier in-house developed equipment can no longer provide the required quality. Because of a current lack of experience and human resources cooperation with private companies is required for the development of new deposition equipment directly integrated in a glove box. In this paper we describe the design, implementation and validation of the first commercial actinide evaporator in a glove box as well as the optimization of the deposition process. Highly enriched 238U3O8 was converted to 238UF4 powder and several deposition runs were performed on different substrates. The deposition parameters were varied and defined in order to guarantee physical and chemical stable homogeneous UF4 layers, even on polished substrates which was not longer feasible with the older equipment. The stability problem is discussed in view of the thin layer growth by physical vapour deposition and the influence of the deposition parameters on the layer quality. The deposits were characterized for the total mass by means of substitution weighing and for the areal density of 238U by means of alpha particle counting and thermal ionization mass spectrometry (TIMS). The quality of the layer was visually evaluated and by means of stereo microscopy and auto radiography.
Knitted outer gloves in primary hip and knee arthroplasty.
Tanner, J; Wraighte, P; Howard, P
2006-01-01
A randomised trial was carried out to determine the rate of perforation to inner gloves when comparing latex with knitted gloves during hip and knee arthroplasty. Members of the surgical team were randomised to wear either two pairs of latex gloves (standard double gloving) or a knitted glove on top of a latex glove. In addition, participants completed a visual analogue assessment of their overall satisfaction with the gloves. A total of 406 inner gloves were tested for perforations over a four-month period: 23% of inner gloves were perforated when latex outer gloves were used and 6% of inner gloves were perforated when knitted outer gloves were used. In total, there were 64 perforations to the inner gloves; only one of these perforations was detected by the glove wearer. Wearing knitted outer gloves during hip and knee arthroplasty statistically significantly reduces the risk of perforation to inner latex gloves (p<0.0001).
NASA Technical Reports Server (NTRS)
Abeles, F. J.
1980-01-01
Each of the subsystems comprising the protective ensemble for firefighters is described. These include: (1) the garment system which includes turnout gear, helmets, faceshields, coats, pants, gloves, and boots; (2) the self-contained breathing system; (3) the lighting system; and (4) the communication system. The design selection rationale is discussed and the drawings used to fabricate the prototype ensemble are provided. The specifications presented were developed using the requirements and test method of the protective ensemble standard. Approximate retail prices are listed.
Wearing gloves in the hospital
Infection control - wearing gloves; Patient safety - wearing gloves; Personal protective equipment - wearing gloves; PPE - wearing gloves; Nosocomial infection - wearing gloves; Hospital acquired infection - wearing gloves
Tracking cross-contamination transfer dynamics at a mock retail deli market using GloGerm.
Maitland, Jessica; Boyer, Renee; Gallagher, Dan; Duncan, Susan; Bauer, Nate; Kause, Janell; Eifert, Joseph
2013-02-01
Ready-to-eat (RTE) deli meats are considered a food at high risk for causing foodborne illness. Deli meats are listed as the highest risk RTE food vehicle for Listeria monocytogenes. Cross-contamination in the retail deli market may contribute to spread of pathogens to deli meats. Understanding potential cross-contamination pathways is essential for reducing the risk of contaminating various products. The objective of this study was to track cross-contamination pathways through a mock retail deli market using an abiotic surrogate, GloGerm, to visually represent how pathogens may spread through the deli environment via direct contact with food surfaces. Six contamination origination sites (slicer blade, meat chub, floor drain, preparation table, employee's glove, and employee's hands) were evaluated separately. Each site was inoculated with 20 ml of GloGerm, and a series of standard deli operations were completed (approximately 10 min of work). Photographs were then taken under UV illumination to visualize spread of GloGerm throughout the deli. A sensory panel evaluated the levels of contamination on the resulting contaminated surfaces. Five of the six contamination origination sites were associated with transfer of GloGerm to the deli case door handle, slicer blade, meat chub, preparation table, and the employee's gloves. Additional locations became contaminated (i.e., deli case shelf, prep table sink, and glove box), but this contamination was not consistent across all trials. Contamination did not spread from the floor drain to any food contact surfaces. The findings of this study reinforce the need for consistent equipment cleaning and food safety practices among deli workers to minimize cross-contamination.
A preview of a microgravity laser light scattering instrument
NASA Astrophysics Data System (ADS)
Meyer, W. V.; Ansari, R. R.
1991-01-01
The development of a versatile, miniature, modular light scattering instrument to be used in microgravity is described. The instrument will measure microscopic particles in the size range of thirty angstroms to above three microns. This modular instrument permits several configurations, each optimized for a particular experiment. In particular, a multiangle instrument will probably be mounted in a rack in the Space Shuttle and on the Space Station. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations.
Frequency of glove perforation and the protective effect of double gloves in gynecological surgery.
Murta, Eddie F C; Silva, Cléber S; Júnior, Odilon R A
2003-06-01
The purposes of this prospective study were to verify the frequency of glove perforation during gynecological operations and to evaluate the efficacy of double gloving in preventing damage to the inner glove. From May 2000 to May 2001, three house staff and 12 residents were asked to place their used gloves in bags labeled with the following information: procedure performed, presence of a recognized glove perforation, and role in operating team (surgeon, first or second assistant, and instrumentalist). All glove sets were tested using the method of water pression. Damaged gloves were excluded from that analysis. In all, 35 and 51 operations were utilized with single and double gloves, respectively. There were 240 single gloves and 792 double gloves tested. Perforation occurred in 10.4% of the single gloves and 9.8% of the outer double gloves. There were no cases of perforation in the inner double gloves. In cases of operating time that lasted more than 2 h, 56% of the surgeries that used single gloves had perforation vs 58.5% of the double gloves. The first assistant had the major risk for glove perforation with the use of single or double gloves. The indicator finger of the non-dominant hand was the major risk for perforation. In conclusion, we recommend double gloving in all gynecological surgery to reduce the risk of contracting blood-borne diseases.
Hayes, Galina; Singh, Ameet; Gibson, Tom; Moens, Noel; Oblak, Michelle; Ogilvie, Adam; Reynolds, Debbie
2017-10-01
To determine the influence of orthopedic reinforced gloves on contamination events during small animal orthopedic surgery. Prospective randomized controlled trial SAMPLE POPULATION: Two hundred and thirty-seven pairs of orthopedic gloves (474 gloves) and 203 pairs of double standard gloves (812 gloves) worn during 193 orthopedic procedures. Primary and assistant surgeons were randomized to wear either orthopedic reinforced gloves or double gloves. Gloves were leak tested to identify perforations at the end of procedures. Perforations detected intraoperatively or postoperatively were recorded. A contamination event was defined as at least one perforation on either hand for orthopedic reinforced gloves, or a perforation of both the inner and outer glove on the same hand for double gloves. Baseline characteristics between the 2 intervention groups were similar. There was no difference in contamination events between the double-gloved and orthopedic gloved groups (OR = 0.95, 95% CI = 0.49-1.87, P = .89). The same percentage of contamination events (8% glove pairs used) occurred in the double gloved group (17 contamination events) and in the orthopedic gloved group (19 contamination events). The odds of a contamination event increased by 1.02 (95% CI 1.01-1.03, P < .001) with each additional minute of surgery. Orthopedic reinforced gloves and double standard gloving were equally effective at preventing contamination events in small animal orthopedic procedures. Surgeons reluctant to double glove due to perceptions of decreased dexterity and discomfort may safely opt for wearing orthopedic gloves, which may improve their compliance. © 2017 The American College of Veterinary Surgeons.
Design and Evaluation of a Soft and Wearable Robotic Glove for Hand Rehabilitation.
Biggar, Stuart; Yao, Wei
2016-10-01
In the modern world, due to an increased aging population, hand disability is becoming increasingly common. The prevalence of conditions such as stroke is placing an ever-growing burden on the limited fiscal resources of health care providers and the capacity of their physical therapy staff. As a solution, this paper presents a novel design for a wearable and adaptive glove for patients so that they can practice rehabilitative activities at home, reducing the workload for therapists and increasing the patient's independence. As an initial evaluation of the design's feasibility the prototype was subjected to motion analysis to compare its performance with the hand in an assessment of grasping patterns of a selection of blocks and spheres. The outcomes of this paper suggest that the theory of design has validity and may lead to a system that could be successful in the treatment of stroke patients to guide them through finger flexion and extension, which could enable them to gain more control and confidence in interacting with the world around them.
Exogrip: assisted hand strength glove - biomed 2011.
Best, Jade E; Bostick, Nehemiah F; Connelly, John R; Dunn, Michael G; Gelles, Richard A; Norvell, Elizabeth K; Waugaman, William B; Mims, Capt Willie H
2011-01-01
A large number of American troops fighting in Afghanistan and Iraq have received wounds in their upper extremities leading to significant nerve damage and loss of strength. These injuries impair their ability to perform day-to-day tasks such as lifting a cup of coffee or opening a door. Although the cause of some injuries in service-people is often unique to their employment, civilian employees in other industries are also plagued with similar physical damage due to other kinds of injuries. Our goal is to develop a device to augment the strength of injured troops and civilian workers so they can perform everyday tasks despite their physical limitations. The ExoGrip is a glove designed to provide this necessary strength augmentation. The ExoGrip consists primarily of pressure sensors, linear actuators, and a microcontroller to provide a force multiplier based on a persons strength. The goal of the first phase of the project was to conduct research and also produce a working prototype of one finger. This goal was achieved by a group of classmates who started the project a year before. Their research and feasibility analysis ended in the mechanical movement of a single finger when the sensors were activated. The next phase of this project is to design and integrate a working prototype that manipulates all four fingers, while keeping the thumb in a fixed position. This paper describes the integration of new microcontrollers, linear actuators utilizing pulse width modulation technology, and improved pressure sensors needed to manipulate the fingers, as well as laying the foundation for future testing and development of a final product.
Glove perforation rate in vascular surgery--a comparison between single and double gloving.
Aarnio, P; Laine, T
2001-05-01
In surgery intact gloves act as a sterile barrier between surgeon and patient. The impermeable gloves protect the surgeon from bloodborne pathogens such as HIV, hepatitis B, and hepatitis C. On the other hand, the surgical wound is protected from micro-organisms from the skin of the surgeon. One objective of this study was to compare puncture rates between the double gloving color indication system and single-use gloves and the other to determine the extent to which glove perforations remain undetected during the course of vascular surgical operations. The study material comprised all gloves used in vascular surgical operations at Satakunta Central Hospital for a period of two months. The analysis was made by the glove type in a prospective and randomised manner. Gloves were tested immediately after the surgical procedure using the approved standardized water-leak method. With this method the glove is filled with water using a special filling tube, and the water-filled glove is then checked for two minutes to detect any holes. The gloves used in this study were either double gloves with indicator, or the standard glove used at our hospital. In 73 operations altogether 200 gloves were tested, half of them were double gloves and half were single gloves. The perforation occurred in the double gloves 3 times and with single gloves 12 times. The overall perforation rate was 15 out of 200 gloves (7.5%). The detection of perforation during surgery was 60%. Most frequently the perforation was located in the second finger of the left hand, 9 out of 15 perforations. In view of the critical importance of safety at work both transmitting the pathogens from the skin of the surgeon to the wound and transmitting the bloodborne pathogens from the patient to the surgeon, it is very important to use double gloving at least in operations where there is a high risk of glove perforation.
Glove Use and Glove Education in Workers with Hand Dermatitis.
Rowley, Kyle; Ajami, Daana; Gervais, Denise; Mooney, Lindsay; Belote, Amy; Kudla, Irena; Switzer-McIntyre, Sharon; Holness, D Linn
2016-01-01
Occupational skin diseases are common. The occurrence of occupational skin diseases represents a failure of primary prevention strategies that may include the use of personal protective equipment, most commonly gloves. The objective of this study was to describe current glove use and education practices related to gloves in workers being assessed for possible work-related hand dermatitis. Participants included consecutive patients being assessed for possible work-related hand dermatitis. A self-administered questionnaire obtained information on demographics, workplace characteristics and exposures, glove use, and education regarding gloves. Ninety percent of the 105 participants reported using gloves. Only 44% had received training related to glove use in the workplace. Major gaps in training content included skin care when using gloves, warning signs of skin problems, and glove size. If the worker indicated no glove training received, the majority reported they would have used gloves if such training was provided. Although the majority of workers being assessed wore gloves, the minority had received training related to glove use. Particular gaps in training content were identified. Those who had not received training noted they would likely have used gloves if training had been provided.
Cournoyer, Michael E.; Lawton, Cindy M.; Lounsbury, James B.; ...
2016-03-22
We use hand gloves (hereafter referred to as gloves) in the detonator manufacturing and packaging operations. As part of a process improvement program, new glove formulations have been considered that lower the overall risk of detonator operations by reducing ergonomic injury factors. Gloves with a specially treated surface for extra grip and control are now commercially available and have been recommended for use in detonator operations. A Glove Likeability Study demonstrated that detonator manufacturing and packaging workers prefer gloves with a specially treated surface over currently approved gloves made from latex and nitrile formulations. Glove material compatibility tests indicate thatmore » the recommended gloves are as compatible if not more compatible as the currently approved gloves for working with secondary explosives. Thus, these gloves with a specially treated surface for extra grip and control are now available for tasks where sensitivity and fingertip control are crucial. Replacement of the current gloves with gloves with a specially treated surface improves the safety configuration of detonator manufacturing and packaging operations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cournoyer, Michael E.; Lawton, Cindy M.; Lounsbury, James B.
We use hand gloves (hereafter referred to as gloves) in the detonator manufacturing and packaging operations. As part of a process improvement program, new glove formulations have been considered that lower the overall risk of detonator operations by reducing ergonomic injury factors. Gloves with a specially treated surface for extra grip and control are now commercially available and have been recommended for use in detonator operations. A Glove Likeability Study demonstrated that detonator manufacturing and packaging workers prefer gloves with a specially treated surface over currently approved gloves made from latex and nitrile formulations. Glove material compatibility tests indicate thatmore » the recommended gloves are as compatible if not more compatible as the currently approved gloves for working with secondary explosives. Thus, these gloves with a specially treated surface for extra grip and control are now available for tasks where sensitivity and fingertip control are crucial. Replacement of the current gloves with gloves with a specially treated surface improves the safety configuration of detonator manufacturing and packaging operations.« less
Simplified Abrasion Test Methodology for Candidate EVA Glove Lay-Ups
NASA Technical Reports Server (NTRS)
Rabel, Emily; Aitchison, Lindsay
2015-01-01
During the Apollo Program, space suit outer-layer fabrics were badly abraded after performing just a few extravehicular activities (EVAs). For example, the Apollo 12 commander reported abrasive wear on the boots that penetrated the outer-layer fabric into the thermal protection layers after less than 8 hrs of surface operations. Current plans for the exploration planetary space suits require the space suits to support hundreds of hours of EVA on a lunar or Martian surface, creating a challenge for space suit designers to utilize materials advances made over the last 40 years and improve on the space suit fabrics used in the Apollo Program. Over the past 25 years the NASA Johnson Space Center Crew and Thermal Systems Division has focused on tumble testing as means of simulating wear on the outer layer of the space suit fabric. Most recently, in 2009, testing was performed on 4 different candidate outer layers to gather baseline data for future use in design of planetary space suit outer layers. In support of the High Performance EVA Glove Element of the Next Generation Life Support Project, testing a new configuration was recently attempted in which require 10% of the fabric per replicate of that need in 2009. The smaller fabric samples allowed for reduced per sample cost and flexibility to test small samples from manufacturers without the overhead to have a production run completed. Data collected from this iteration was compared to that taken in 2009 to validate the new test method. In addition the method also evaluated the fabrics and fabric layups used in a prototype thermal micrometeoroid garment (TMG) developed for EVA gloves under the NASA High Performance EVA Glove Project. This paper provides a review of previous abrasion studies on space suit fabrics, details methodologies used for abrasion testing in this particular study, results of the validation study, and results of the TMG testing.
NASA Ames Research Center R and D Services Directorate Biomedical Systems Development
NASA Technical Reports Server (NTRS)
Pollitt, J.; Flynn, K.
1999-01-01
The Ames Research Center R&D Services Directorate teams with NASA, other government agencies and/or industry investigators for the development, design, fabrication, manufacturing and qualification testing of space-flight and ground-based experiment hardware for biomedical and general aerospace applications. In recent years, biomedical research hardware and software has been developed to support space-flight and ground-based experiment needs including the E 132 Biotelemetry system for the Research Animal Holding Facility (RAHF), E 100 Neurolab neuro-vestibular investigation systems, the Autogenic Feedback Systems, and the Standard Interface Glove Box (SIGB) experiment workstation module. Centrifuges, motion simulators, habitat design, environmental control systems, and other unique experiment modules and fixtures have also been developed. A discussion of engineered systems and capabilities will be provided to promote understanding of possibilities for future system designs in biomedical applications. In addition, an overview of existing engineered products will be shown. Examples of hardware and literature that demonstrate the organization's capabilities will be displayed. The Ames Research Center R&D Services Directorate is available to support the development of new hardware and software systems or adaptation of existing systems to meet the needs of academic, commercial/industrial, and government research requirements. The Ames R&D Services Directorate can provide specialized support for: System concept definition and feasibility Mathematical modeling and simulation of system performance Prototype hardware development Hardware and software design Data acquisition systems Graphical user interface development Motion control design Hardware fabrication and high-fidelity machining Composite materials development and application design Electronic/electrical system design and fabrication System performance verification testing and qualification.
Performance Analysis of Exam Gloves Used for Aseptic Rodent Surgery
LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie
2015-01-01
Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP–PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham ‘exertion’ activity. According to these criteria, 94% of HP–PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP–PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries. PMID:26045458
Performance analysis of exam gloves used for aseptic rodent surgery.
LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie
2015-05-01
Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP-PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham 'exertion' activity. According to these criteria, 94% of HP-PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP-PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries.
Nielsen, Jesper Bo; Sørensen, Jens Ahm
2012-02-15
Protective gloves are used to reduce dermal exposure when managing chemical exposures at the work place. Different glove materials may offer different degrees of protection. The present study combined the traditional ASTM (American Society for Testing and Materials) model with the Franz diffusion cell to evaluate overall penetration through glove and skin as well as the deposition in the different reservoirs. Benzoic acid was applied on latex or nitrile gloves placed on top of human skin. The amounts of chemical were quantified in the glove material, between glove and skin, within the skin, and in the receptor chamber. Both glove materials reduce total penetration of benzoic acid, but nitrile gloves offer a significantly better protection than latex gloves. This difference was less pronounced at the higher of the two concentrations of benzoic acid applied. Thus, glove types that offer relevant protection at low concentrations does not necessarily give appropriate protection at high concentrations. Significant amounts of benzoic acid could be extracted from the glove materials after exposure. If a chemical is accumulated in the glove material, reuse of single-use gloves should be cautioned. The reuse of gloves is generally not to be recommended without effective decontamination. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Cooper, Ken; Gordon, Gail (Technical Monitor)
2001-01-01
This article offers an unfiltered look at a large cross section of the different rapid prototyping technologies available today; from a guy with one of the biggest RP toy boxes in the world as the manager of the Rapid Prototyping Laboratory at NASA's Marshall Space Flight Center (MSFC) in Huntsville, AL, USA. NASA's current operation capacity is nine RP machines, representing eight actual technologies. The article presents a realistic, unbiased look at the technologies and offers advice on what to do and where to go for the best solution to your rapid prototyping needs.
EV space suit gloves (passive)
NASA Technical Reports Server (NTRS)
Fletcher, E. G.; Dodson, J. D.; Elkins, W.; Tickner, E. G.
1975-01-01
A pair of pressure and thermal insulating overgloves to be used with an Extravehicular (EV) suit assembly was designed, developed, fabricated, and tested. The design features extensive use of Nomex felt materials in lieu of the multiple layer insulation formerly used with the Apollo thermal glove. The glove theoretically satisfies all of the thermal requirements. The presence of the thermal glove does not degrade pressure glove tactility by more than the acceptable 10% value. On the other hand, the thermal glove generally degrades pressure glove mobility by more than the acceptable 10% value, primarily in the area of the fingers. Life cycling tests were completed with minimal problems. The thermal glove/pressure glove ensemble was also tested for comfort; the test subjects found no problems with the thermal glove although they did report difficulties with pressure points on the pressure glove which were independent of the thermal glove.
Choosing the right surgical glove: an overview and update.
Tanner, Judith
Sterile surgical gloves are routinely worn during all invasive procedures to prevent the two-way transmission of pathogens between the surgical team and the patient. This reduces the risk of surgical-site infections and blood-borne diseases. Since their introduction to the operating room over 100 years ago, surgical gloves, and the materials used to make them, have continued to evolve in line with ever-changing healthcare demands. Following recent developments in surgical glove technologies, including de-proteinized natural rubber latex and newer gloving methods such as triple gloving, it is timely that an overview and update of surgical gloves is given. By providing information on latex-associated allergies, glove materials, gloving methods and glove protection, this article will enable practitioners to choose the most appropriate surgical glove.
Mobility of the elastic counterpressure space suit glove.
Tanaka, Kunihiko; Danaher, Patrick; Webb, Paul; Hargens, Alan R
2009-10-01
To evaluate the mobility of the current gas-pressurized glove of the extravehicular mobility unit (G-glove) and the elastic counterpressure glove (E-glove), we investigated range of motion (ROM) and indices of fatigue during grip endurance with both gloves using a bare hand as a control. In nine healthy male right-handed subjects, ROM of the proximal interphalangeal joint of the left middle finger was measured. The median frequency of electromyography (EMG) of the left flexor carpi radialis during grip with 25% of maximum strength was measured with the bare hand, G-glove, and E-glove. Using Borg's scale, discomfort was assessed during each grip test. ROM of the E-glove was similar to that of the bare hand (91 +/- 3 degrees and 97 +/- 1 degree for the E-glove and bare hand, respectively) and significantly higher than that of the G-glove (74 +/- 2 degrees). The change in the median frequency of the EMG, which is correlated with Borg's scale, was significantly smaller using the E-glove at marker time points of 1/4 and 1/2 of the total endurance time (-3.5 +/- 1.5 and -10.4 +/- 1.2 Hz) compared to those for the G-glove (-10.1 +/- 1.1 and -16.7 +/- 1.9 Hz). Thus, the G-glove had faster onset of fatigue than the E-glove. These results suggest the E-glove has better mobility and is more suitable for fine motor tasks as compared to the G-glove.
Glove perforation in hip and knee arthroplasty.
Demircay, Emre; Unay, Koray; Bilgili, Mustafa G; Alataca, Gulum
2010-11-01
The transmission of blood-borne pathogens during surgery is a major concern. Surgical gloves are the primary barrier between the surgeon and the patient. Surgical procedures that need manual handling of bony surfaces or sharp instruments have the highest risk of glove perforations. The frequencies and the sites of surgical glove perforations in arthroplasty procedures were assessed. We assessed the surgical glove perforations in total hip and knee arthroplasty procedures. Double standard latex gloves were used. A total of 983 outer and 511 inner gloves were tested. The gloves of all the surgical team members were tested for perforations during the first and second hours of surgery. There were 18.4% outer and 8.4% inner glove perforations. The most frequent site of perforation was the second digit of the nondominant hand (25.5%). We found that hip and knee arthroplasty had significantly more glove perforation risk for the surgeon in the first half of the operation rather than the second half, and 57.8% of the perforations were at the index finger and the thumb. Arthroplasty procedures still have high glove perforation rates despite the use of double gloving with frequent changes. Extra augmentation of the gloves in selected areas of the hand, in addition to double gloving, may be safer and more cost-effective than double gloving alone.
Prospective randomized assessment of single versus double-gloving for general surgical procedures.
Na'aya, H U; Madziga, A G; Eni, U E
2009-01-01
There is increased tendency towards double-gloving by general surgeons in our practice, due probably to awareness of the risk of contamination with blood or other body fluids during surgery. The aim of the study was to compare the relative frequency of glove puncture in single-glove versus double glove sets in general surgical procedures, and to determine if duration of surgery affects perforation rate. Surgeons at random do single or double gloves at their discretion, for general surgical procedures. All the gloves used by the surgeons were assessed immediately after surgery for perforation. A total of 1120 gloves were tested, of which 880 were double-glove sets and 240 single-glove sets. There was no significant difference in the overall perforation rate between single and double glove sets (18.3% versus 20%). However, only 2.3% had perforations in both the outer and inner gloves in the double glove group. Therefore, there was significantly greater risk for blood-skin exposure in the single glove sets (p < 0.01). The perforation rate was also significantly greater during procedures lasting an hour or more compared to those lasting less than an hour (p < 0.01). Double-gloving reduces the risk of blood-skin contamination in all general surgical procedures, and especially so in procedures lasting an hour or more.
Eveillard, Matthieu; Raymond, Françoise; Guilloteau, Véronique; Pradelle, Marie-Thérèse; Kempf, Marie; Zilli-Dewaele, Marina; Joly-Guillou, Marie-Laure; Brunel, Patrick
2011-10-01
To assess the impact of a multi-faceted training program on the compliance with hand hygiene and gloving practices. Hand hygiene is considered as the cornerstone of the prevention of hospital-acquired infections. Several studies have enhanced the poor effectiveness of training programs in improving hand hygiene compliance. A before-after evaluation study. The study was conducted in four healthcare settings before and after an intervention program which included the performance feedback of the first evaluation phase, three six-h training sessions, the assessment of hand hygiene performance with teaching boxes and the organisation of one full-day session devoted to institutional communication around hand hygiene in each setting. Hand hygiene compliance and quality of hand rubbing were evaluated. Hand hygiene opportunities were differentiated into extra-series opportunities (before or after a single contact and before the first contact or after the last contact of a series of consecutive contacts) and intra-series opportunities (from the opportunity following the first contact to the opportunity preceding the last in the same series). Overall, 969 contacts corresponding to 1,470 hand hygiene opportunities (760 during the first phase and 710 during the second) were observed. A significant improvement of observed practices was recorded for the hand hygiene compliance in intra-series opportunities (39·0% vs. 19·0%; p < 10(-5) ), the proportion of gloves worn if indicated (71·4% vs. 52·0%; p < 0·001) and the quality of hand rubbing (85·0% vs. 71·9%; p < 10(-5) ). Some of the performances measured for both hand hygiene and gloving practices were improved. We plan to extend this investigation by performing a qualitative study with experts in behavioural sciences to try improving practices for which adherence was still weak after the training program such as hand hygiene in intra-series opportunities. This study underscored the usefulness of implementing contextualised training programs, while more traditional courses have shown little impact. © 2011 Blackwell Publishing Ltd.
Sung, Peng-Cheng
2014-01-01
This study examined the effects of glovebox gloves for 11 females on maximum grip and key pinch strength and on contact forces generated from simulated tasks of a roller, a pair of tweezers and a crescent wrench. The independent variables were gloves fabricated of butyl, CSM/hypalon and neoprene materials; two glove thicknesses; and layers of gloves worn including single, double and triple gloving. CSM/hypalon and butyl gloves produced greater grip strength than the neoprene gloves. CSM/hypalon gloves also lowered contact forces for roller and wrench tasks. Single gloving and thin gloves improved hand strength performances. However, triple layers lowered contact forces for all tasks. Based on the evaluating results, selection and design recommendations of gloves for three hand tools were provided to minimise the effects on hand strength and optimise protection of the palmar hand in glovebox environments. To improve safety and health in the glovebox environments where gloves usage is a necessity, this study provides recommendations for selection and design of glovebox gloves for three hand tools including a roller, a pair of tweezers and a crescent wrench based on the results discovered in the experiments.
Glove utilization in the prevention of cross transmission: a systematic review.
Picheansanthian, Wilawan; Chotibang, Jutamas
2015-05-15
Gloves are worn to protect hands from contamination from microorganisms and to reduce the risks of transmission of microorganisms from healthcare workers to patients and vice versa. However, gloves should be changed between patient contacts and hand washing is necessary before putting on gloves and immediately after removing gloves. The objective of this review was to evaluate and synthesize the best available research evidence that investigates clinical use of gloves in the prevention of cross transmission. Health care workers.Types of intervention(s): Glove use intervention. Types of outcomes: Contamination of healthcare workers' hands, transmission of infections, adherence to glove usage, inappropriate uses of gloves, and adherence to hand hygiene. Types of studies: Quasi-experimental studies and descriptive studies. The search sought to find published and unpublished studies. The time period of the search covered articles published from 2000 to 2012 in English and Thai. The databases searched included: MEDLINE, CINAHL, EMBASE, The Cochrane Library, PubMed, Science Direct, Current Content Connect, Blackwell synergy, Thai Nursing Research Database, Thai thesis database, Digital Library of Thailand Research Fund, Research of National Research Council of Thailand, and Database of Office of Higher Education. Studies selected for retrieval were assessed by two independent reviewers for methodological quality using the Joanna Briggs Institute Meta-Analysis of Statistics Assessment and Review Instrument software. Data extraction was performed using the standardized data extraction tool from the Joanna Briggs Institute Meta-Analysis of Statistics Assessment and Review Instrument software. A meta-synthesis was not possible due to the methodological heterogeneity of the included papers. The evidence was thus presented as a narrative summary. Twenty-three studies were included in this review. The results indicated that contamination of a healthcare worker's gloves with bacteria during routine care activities is common. The use of gloves can protect the hands of healthcare workers from bacterial contamination, but the protection afforded by the gloves was incomplete. Adherence to glove utilization among healthcare workers was suboptimal. Gloves were overused and often misused. The major break in compliance with glove use was failure to change gloves between procedures on the same patient. Inappropriate glove use can increase the risk of cross transmission. It is unclear if modifications in glove use alter compliance with hand hygiene among healthcare workers. Gloving can reduce acquisition of microorganisms on the hands. However, gloving does not completely prevent contamination of the hands. Compliance with glove use among healthcare workers is poor. Gloves were also overused and often misused. Inappropriate glove use can increase the risk of cross transmission via contaminated gloved hands. There is still not enough evidence to prove the influence of glove use on adherence to hand hygiene. This review strengthens the recent suggestion on the use of gloves to reduce bacterial contamination. However, gloving does not completely prevent contamination, thus emphasizing the need for hand antisepsis before and after patient contact. Intervention to improve the use of gloves and hand hygiene compliance after gloving in the healthcare settings should be implemented. Further studies should target poor compliers with glove use and promote strategies that can be evaluated. The Joanna Briggs Institute.
Suspension and simple optical characterization of two-dimensional membranes
NASA Astrophysics Data System (ADS)
Northeast, David B.; Knobel, Robert G.
2018-03-01
We report on a method for suspending two-dimensional crystal materials in an electronic circuit using an only photoresists and solvents. Graphene and NbSe2 are suspended tens of nanometers above metal electrodes with clamping diameters of several microns. The optical cavity formed from the membrane/air/metal structures enables a quick method to measure the number of layers and the gap separation using comparisons between the expected colour and optical microscope images. This characterization technique can be used with just an illuminated microscope with a digital camera which makes it adaptable to environments where other means of characterization are not possible, such as inside nitrogen glove boxes used in handling oxygen-sensitive materials.
Pyrophoric behaviour of uranium hydride and uranium powders
NASA Astrophysics Data System (ADS)
Le Guyadec, F.; Génin, X.; Bayle, J. P.; Dugne, O.; Duhart-Barone, A.; Ablitzer, C.
2010-01-01
Thermal stability and spontaneous ignition conditions of uranium hydride and uranium metal fine powders have been studied and observed in an original and dedicated experimental device placed inside a glove box under flowing pure argon. Pure uranium hydride powder with low amount of oxide (<0.5 wt.%) was obtained by heat treatment at low temperature in flowing Ar/5%H2. Pure uranium powder was obtained by dehydration in flowing pure argon. Those fine powders showed spontaneous ignition at room temperature in air. An in situ CCD-camera displayed ignition associated with powder temperature measurement. Characterization of powders before and after ignition was performed by XRD measurements and SEM observations. Oxidation mechanisms are proposed.
Improved Gloves for Firefighters
NASA Technical Reports Server (NTRS)
Tschirch, R. P.; Sidman, K. R.; Arons, I. J.
1983-01-01
New firefighter's gloves are more flexible and comfortable than previous designs. Since some firefighters prefer gloves made of composite materials while others prefer dip-coated gloves, both types were developed. New gloves also find uses in foundries, steelmills, and other plants where they are substituted for asbestos gloves.
The mechanical and microbiological integrity of surgical gloves.
Jamal, Ala; Wilkinson, Stephen
2003-03-01
Several manufacturers supply surgical gloves that have been individually tested (IT) for leaks. Other manufacturers supply gloves in which sample gloves from each batch are tested for leaks (batch tested: BT). The latter brands may be rejected by surgeons because of presumed increased risk of wound infection and staff exposure to patient pathogens. The influence of differences between glove brands on performance in surgery has not been extensively studied. The aims of the present study were to test the mechanical and microbiological integrity of IT compared to BT gloves. A total of 110 unused gloves from each of an IT and a BT brand were tested for leaks, first, by observation of water-jets from water-filled gloves and second, by measuring electrical resistance between inside and outside the glove surfaces, to give a baseline measure. A total of 304 IT and 280 BT gloves were then similarly leak-tested after 98 clean surgical procedures. The hands and gloves of scrub team members were cultured postsurgery. A total of 1/110 BT and 0/110 IT unused gloves contained leaks (NS, Fisher's exact test). Operative perforation rates were lower for BT compared with IT (8/280 cf. 22/304; P < 0.05 Fisher's exact test). There was no bias in types of operations or scrub team members to account for the difference. Growth of normal skin flora was found on virtually every wearer's hands post-operatively. Similar bacteria were frequently cultured from the outside of gloves at the conclusion of surgery (111/152 pairs IT cf. 122/140 pairs BT; P < 0.01, Fisher's exact test). This study provides evidence that the clinical performance of BT gloves is no different to IT gloves. There was no significant difference in mechanical leak rates for unused gloves. Paradoxically, although IT gloves were more likely to show macro-perforations after surgery, the incidence of contamination on the surface of BT gloves was greater, possibly reflecting a qualitative difference in glove material. This study suggests that both types of gloves develop microporosity during use, which may allow transfer of bacteria from the surgeon's skin to the surface of the glove.
Contamination of Critical Surfaces from NVR Glove Residues Via Dry Handling and Solvent Cleaning
NASA Technical Reports Server (NTRS)
Sovinski, Marjorie F.
2004-01-01
Gloves are often used to prevent the contamination of critical surfaces during handling. The type of glove chosen for use should be the glove that produces the least amount of non-volatile residue (NVR). This paper covers the analysis of polyethylene, nitrile, latex, vinyl, and polyurethane gloves using the contact transfer and gravimetric determination methods covered in the NASA GSFC work instruction Gravimetric Determination and Contact Transfer of Non-volatile Residue (NVR) in Cleanroom Glove Samples, 541-WI-5330.1.21 and in the ASTM Standard E-1731M-95, Standard Test Method for Gravimetric Determination of Non-Volatile Residue from Cleanroom Gloves. The tests performed focus on contamination of critical surfaces at the molecular level. The study found that for the most part, all of the gloves performed equally well in the contact transfer testing. However, the polyethylene gloves performed the best in the gravimetric determination testing, and therefore should be used whenever solvent contact is a possibility. The nitrile gloves may be used as a substitute for latex gloves when latex sensitivity is an issue. The use of vinyl gloves should be avoided, especially if solvent contact is a possibility. A glove database will be established by Goddard Space Flight Center (GSFC) Code 541 to compile the results from future testing of new gloves and different glove lots.
Incidence of glove failure during orthopedic operations and the protective effect of double gloves.
Thanni, Lateef O A; Yinusa, W
2003-12-01
To determine the usefulness of double gloves in protecting against the exposure of surgical team members' hands to blood. Five-hundred-ninety-six gloves were studied during 71 orthopedic operations using the water-loading test (filling a glove with water and occluding its cuff tightly to identify leaking points). In all, 73 glove perforations occurred, but only nine resulted in exposure to blood (blood touching the skin). The incidence of glove perforation was 12% (73/596), and overall exposure (blood touching the skin) per operation was 13% (9/71). The latter would have been 87% (62/71) but for the use of double gloves. Sixteen percent of the perforations in double gloves were in the inner gloves, while 84% were in the outer gloves. Exposure of surgeons was reduced from 54% to 10%, first assistants from 27% to 3%, and second assistants from 7% to 0 (p < 0.02, df = 2) by double-gloving. Significantly more perforations occurred during operations on bone, compared with soft tissue operations, p < 0.0001, RR = 4 (95% CL 1.87-8.55). The most common sites of glove perforation were the index finger (47%), thumb, and the palm region: 14% each. More glove perforations occurred in nondominant hands. Double-gloving offers additional protection to surgeons and assistants by preventing hand exposure to blood intraoperatively.
Phalen, Robert N; Le, Thi; Wong, Weng Kee
2014-01-01
Glove movement can affect chemical permeation of organic compounds through polymer glove products. However, conflicting reports make it difficult to compare the effects of movement on chemical permeation through commonly available glove types. The aim of this study was to evaluate the effect of movement on chemical permeation of an organic solvent through disposable latex, nitrile, and vinyl gloves. Simulated whole-glove permeation testing was conducted using ethyl alcohol and a previously designed permeation test system. With exposure to movement, a significant decrease (p ≤ 0.001) in breakthrough time (BT) was observed for the latex (-23%) and nitrile gloves (-31%). With exposure to movement, only the nitrile glove exhibited a significant increase (p ≤ 0.001) in steady-state permeation rate (+47%) and cumulative permeation at 30 min (+111%). Even though the nitrile glove provided optimum chemical resistance against ethyl alcohol, it was most affected by movement. With exposure to movement, the latex glove was an equivalent option for overall worker protection, because it was less affected by movement and the permeation rate was lower than that of the nitrile glove. In contrast, the vinyl glove was the least affected by movement, but did not provide adequate chemical resistance to ethyl alcohol in comparison with the nitrile and latex gloves. Glove selection should take movement and polymer type into account. Some glove polymer types are less affected by movement, most notably the latex glove in this test. With nitrile gloves, at least a factor of three should be used when attempting to assign a protection factor when repetitive hand motions are anticipated. Ultimately, the latex gloves outperformed nitrile and vinyl in these tests, which evaluated the effect of movement on chemical permeation. Future research should aim to resolve some of the observed discrepancies in test results with latex and vinyl gloves.
Phalen, Robert N.; Le, Thi; Wong, Weng Kee
2014-01-01
Glove movement can affect chemical permeation of organic compounds through polymer glove products. However, conflicting reports make it difficult to compare the effects of movement on chemical permeation through commonly available glove types. This study was aimed to evaluate the effect of movement on chemical permeation of an organic solvent through disposable latex, nitrile, and vinyl gloves. Simulated whole-glove permeation testing was conducted using ethyl alcohol and a previously designed permeation test system. With exposure to movement, a significant decrease (p ≤ 0.001) in breakthrough time was observed for the latex (-23%) and nitrile gloves (-31%). With exposure to movement, only the nitrile glove exhibited a significant increase (p ≤ 0.001) in steady-state permeation rate (+47%) and cumulative permeation at 30 min (+111%). Even though the nitrile glove provided optimum chemical resistance against ethyl alcohol, it was most affected by movement. With exposure to movement, the latex glove was an equivalent option for overall worker protection, because it was less affected by movement and the permeation rate was lower than that of the nitrile glove. In contrast, the vinyl glove was the least affected by movement, but did not provide adequate chemical resistance to ethyl alcohol in comparison with the nitrile and latex gloves. In conclusion, glove selection should take movement and polymer type into account. Some glove polymer types are less affected by movement, most notably the latex glove in this test. With nitrile gloves, at least a factor of three should be used when attempting to assign a protection factor when repetitive hand motions are anticipated. Ultimately, the latex gloves outperformed nitrile and vinyl in these tests, which evaluated the effect of movement on chemical permeation. Future research should aim to resolve some of the observed discrepancies in test results with latex and vinyl gloves. PMID:24689368
Testing of Prototype Magnetic Suspension Cryogenic Transfer Line
NASA Astrophysics Data System (ADS)
Fesmire, J. E.; Augustynowicz, S. D.; Nagy, Z. F.; Sojourner, S. J.; Shu, Q. S.; Cheng, G.; Susta, J. T.
2006-04-01
A 6-meter prototype cryogenic transfer line with magnetic suspension was tested for its mechanical and thermal performance at the Cryogenics Test Laboratory of NASA Kennedy Space Center (KSC). A test facility with two cryogenic end-boxes was designed and commissioned for the testing. Suspension mechanisms were verified through a series of tests with liquid nitrogen. The thermal performance of the prototype was determined using the new test apparatus. The tested prototype has incorporated temperature and vacuum pressure data acquisition ports, customized interfaces to cryogenic end-boxes, and instrumentation. All tests were conducted under simulated onsite transfer line working conditions. A static (boiloff rate measurement) testing method was employed to demonstrate the gross heat leak in the tested article. The real-time temperature distribution, vacuum level, levitation distance, and mass flow rate were measured. The main purpose of this paper is to summarize the testing facility design and preparation, test procedure, and primary test results. Special arrangements (such as turning on/off mechanical support units, observing levitation gap, and setting up the flowmeter) in testing of such a magnetically levitated transfer line are also discussed. Preliminary results show that the heat leak reduction of approximately one-third to one-half is achievable through such transfer lines with a magnetic suspension system.
EVALUATION OF GLOVEBOX GLOVES FOR EFFECTIVE PERMEATION CONTROL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korinko, P.
A research and development task was undertaken to determine the permeabilities of hydrogen and dry air through different polymeric glove materials that are used to maintain the integrity of glovebox secondary containment. Fifteen different glove samples were obtained from four different manufacturers and samples cut from these gloves were tested. The gloves included baseline butyl rubber, Viton{reg_sign}, Dupont{reg_sign} Hypalon{reg_sign}, polyurethane, as well as composite gloves. The testing indicated that all of the vendor's butyl rubber gloves and the Jung Viton{reg_sign} gloves performed comparably in both gases.
A novel method of assessing the effectiveness of protective gloves--results from a pilot study.
Creely, K S; Cherrie, J W
2001-03-01
We have devised a novel method for evaluating the effectiveness of protective gloves and have undertaken a small study to assess this approach. Three types of glove were tested in a standardised simulation test with a permethrin-based pesticide. Prewashed cotton gloves were used to collect the samples. One was worn over the protective glove on one hand to measure the potential deposition of pesticide on the hands had the gloves not been worn. A second was placed under the protective glove on the opposite hand to measure the actual deposition of permethrin on the hands when the gloves were worn. This regime was reversed half way through each test in an attempt to prevent bias. Measurable inner glove contamination occurred on 25 out of 30 occasions. Geometric mean protection factors were calculated from the ratio of outer and inner sampling glove contamination, with average protection factors of 470, 200 and 96 being obtained for the two nitrile and PVC gloves, respectively. The PVC gloves were the least effective in preventing inner glove contamination, probably because the glove was thick and fairly inflexible, causing more pesticide to enter the glove around the cuff. Although the tasks were standardised, variability occurred due to worker behaviour and equipment failure. The spray pump failed on five occasions, resulting in higher levels of inner glove contamination and a geometric mean protection factor of 32. On the occasions when the pump worked correctly, the level of protection provided by the gloves rose dramatically with mean protection factors of 220 and 450 being obtained for workers categorised as "messy" and "tidy", respectively.
30 CFR 77.606-1 - Rubber gloves; minimum requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COAL MINES Trailing Cables § 77.606-1 Rubber gloves; minimum requirements. (a) Rubber gloves (lineman's gloves) worn while handling high-voltage trailing cables shall be rated at least 20,000 volts and shall... gloves (wireman's gloves) worn while handling trailing cables energized by 660 to 1,000 volts shall be...
Black Box Testing: Experiments with Runway Incursion Advisory Alerting System
NASA Technical Reports Server (NTRS)
Mukkamala, Ravi
2005-01-01
This report summarizes our research findings on the Black box testing of Runway Incursion Advisory Alerting System (RIAAS) and Runway Safety Monitor (RSM) system. Developing automated testing software for such systems has been a problem because of the extensive information that has to be processed. Customized software solutions have been proposed. However, they are time consuming to develop. Here, we present a less expensive, and a more general test platform that is capable of performing complete black box testing. The technique is based on the classification of the anomalies that arise during Monte Carlo simulations. In addition, we also discuss a generalized testing tool (prototype) that we have developed.
NASA Technical Reports Server (NTRS)
Reid, Christopher; Benson, Elizabeth; England, Scott; Charvat, Jacqueline; Norcross, Jason; McFarland, Shane; Rajulu, Sudhakar
2014-01-01
From the time hand-intensive tasks were first created for EVAs, discomforts and injuries have been noted.. There have been numerous versions of EVA gloves for US crew over the past 50 years, yet pain and injuries persist. The investigation team was tasked with assisting in a glove injury assessment for the High Performance EVA Glove (HPEG) project.center dot To aid in this assessment, the team was asked to complete the following objectives: - First, to develop the best current understanding of what glove-related injuries have occurred to date, and when possible, identify the specific mechanisms that caused those injuries - Second, to create a standardized method for comparison of glove injury potential from one glove to another. center dot The overall goal of the gloved hand injury assessment is to utilize ergonomics in understanding how these glove injuries are occurring, and to propose mitigations to current designs or design changes in the next generation of EVA gloves.
Optimizing skin protection with semipermeable gloves.
Wulfhorst, Britta; Schwanitz, Hans Joachim; Bock, Meike
2004-12-01
Occlusion due to gloves is one important cause of glove irritation. Macerated softened skin gives poor protection against microbes and chemical injuries. The introduction of a breathable protective glove material would represent a significant step toward improved prevention of occupational skin disease. Performance levels of semipermeable and occlusive gloves were examined under conditions typical of the hairdressing profession. In two studies, tests comparing breathable semipermeable gloves to single-use gloves made of occlusive materials were conducted. In an initial study, a user survey was carried out in conjunction with bioengineering examinations. Values at baseline and values after gloves were worn were recorded by measuring transepidermal water loss (TEWL), skin humidity (SH), and skin surface hydrogen ion concentration (pH) in 20 healthy volunteers. In a second study, the gloves were tested for penetrability and permeability with three chemical compounds typically used in the hairdressing profession. Bioengineering examination objectively confirmed users' reports of reduced hand perspiration when semipermeable gloves were worn. The TEWL, SH, and skin surface pH values remained largely stable after 20 minutes of wearing semipermeable gloves, in contrast to the reactions observed with gloves of occlusive materials. Permeability tests indicated that the semipermeable material is effective, with some restrictions. Air leakage testing revealed that all 50 gloves tested were not airtight. Following the optimization of manufacturing methods, additional tests of the penetrability of semipermeable gloves will be necessary.
Reliability and performance of innovative surgical double-glove hole puncture indication systems.
Edlich, Richard F; Wind, Tyler C; Heather, Cynthia L; Thacker, John G
2003-01-01
During operative procedures, operating room personnel wear sterile surgical gloves designed to protect them and their patients against transmissible infections. The Food and Drug Administration (FDA) has set compliance policy guides for manufacturers of gloves. The FDA allows surgeons' gloves whose leakage defect rates do not exceed 1.5 acceptable quality level (AQL) to be used in operating rooms. The implications of this policy are potentially enormous to operating room personnel and patients. This unacceptable risk to the personnel and patient could be significantly reduced by the use of sterile double surgical gloves. Because double-gloves are also susceptible to needle puncture, a double-glove hole indication system is urgently needed to immediately detect surgical needle glove punctures. This warning would allow surgeons to remove the double-gloves, wash their hands, and then don a sterile set of double-gloves with an indication system. During the last decade, Regent Medical has devised non-latex and latex double-glove hole puncture indication systems. The purpose of this comprehensive study is to detect the accuracy of the non-latex and latex double-glove hole puncture indication systems using five commonly used sterile surgical needles: the taper point surgical needle, tapercut surgical needle, reverse cutting edge surgical needle, taper cardiopoint surgical needle, and spatula surgical needle. After subjecting both the non-latex and latex double-glove hole puncture indication systems to surgical needle puncture in each glove fingertip, these double-glove systems were immersed in a sterile basin of saline, after which the double-gloved hands manipulated surgical instruments. Within two minutes, both the non-latex and latex hole puncture indication systems accurately detected needle punctures in all of the surgical gloves, regardless of the dimensions of the surgical needles. In addition, the size of the color change visualized through the translucent outer glove did not correlate with needle diameter. On the basis of this extensive experimental evaluation, both the non-latex and latex double-glove hole puncture indication systems should be used in all operative procedures by all operating room personnel.
Dong, Ren G.; Welcome, Daniel E.; Peterson, Donald R.; Xu, Xueyan S.; McDowell, Thomas W.; Warren, Christopher; Asaki, Takafumi; Kudernatsch, Simon; Brammer, Antony
2015-01-01
Vibration-reducing (VR) gloves have been increasingly used to help reduce vibration exposure, but it remains unclear how effective these gloves are. The purpose of this study was to estimate tool-specific performances of VR gloves for reducing the vibrations transmitted to the palm of the hand in three orthogonal directions (3-D) in an attempt to assess glove effectiveness and aid in the appropriate selection of these gloves. Four typical VR gloves were considered in this study, two of which can be classified as anti-vibration (AV) gloves according to the current AV glove test standard. The average transmissibility spectrum of each glove in each direction was synthesized based on spectra measured in this study and other spectra collected from reported studies. More than seventy vibration spectra of various tools or machines were considered in the estimations, which were also measured in this study or collected from reported studies. The glove performance assessments were based on the percent reduction of frequency-weighted acceleration as is required in the current standard for assessing the risk of vibration exposures. The estimated tool-specific vibration reductions of the gloves indicate that the VR gloves could slightly reduce (<5%) or marginally amplify (<10%) the vibrations generated from low-frequency (<25 Hz) tools or those vibrating primarily along the axis of the tool handle. With other tools, the VR gloves could reduce palm-transmitted vibrations in the range of 5%–58%, primarily depending on the specific tool and its vibration spectra in the three directions. The two AV gloves were not more effective than the other gloves with some of the tools considered in this study. The implications of the results are discussed. Relevance to industry Hand-transmitted vibration exposure may cause hand-arm vibration syndrome. Vibration-reducing gloves are considered as an alternative approach to reduce the vibration exposure. This study provides useful information on the effectiveness of the gloves when used with many tools for reducing the vibration transmitted to the palm in three directions. The results can aid in the appropriate selection and use of these gloves. PMID:26726275
Evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration.
Griffin, M J
1998-05-01
A method of evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration is proposed. The glove isolation effectiveness was calculated from: (a) the measured transmissibility of a glove, (b) the vibration spectrum on the handle of a specific tool (or class of tools), and (c) the frequency weighting indicating the degree to which different frequencies of vibration cause injury. With previously reported tool vibration spectra and glove transmissibilities (from 10-1000 Hz), the method was used to test 10 gloves with 20 different powered tools. The frequency weighting for hand-transmitted vibration advocated in British standard 6842 (1987) and international standard 5349 (1986) greatly influences the apparent isolation effectiveness of gloves. With the frequency weighting, the gloves had little effect on the transmission of vibration to the hand from most of the tools. Only for two or three tools (those dominated by high frequency vibration) did any glove provide useful attenuation. Without the frequency weighting, some gloves showed useful attenuation of the vibration on most powered tools. In view of the uncertain effect of the vibration frequency in the causation of disorders from hand-transmitted vibration, it is provisionally suggested that the wearing of a glove by the user of a particular vibratory tool could be encouraged if the glove reduces the transmission of vibration when it is evaluated without the frequency weighting and does not increase the vibration when it is evaluated with the frequency weighting. A current international standard for the measurement and evaluation of the vibration transmitted by gloves can classify a glove as an antivibration glove when it provides no useful attenuation of vibration, whereas a glove providing useful attenuation of vibration on a specific tool can fail the test.
Lefebvre, Daniel R; Strande, Louise F; Hewitt, Charles W
2008-01-01
Acquiring a blood-borne disease is a risk of performing operations. Most data about seroconversion are based on hollow-bore needlesticks. Some studies have examined the inoculation volumes of pure blood delivered by suture needles. There is a lack of data about the effect of double-gloving on contaminant transmission in less viscous fluids that are not prone to coagulation. We used enzymatic colorimetry to quantify the volume of inoculation delivered by a suture needle that was coated with an aqueous contaminant. Substrate color change was measured using a microplate reader. Both cutting and tapered suture needles were tested against five different glove types and differing numbers of glove layers (from zero to three). One glove layer removed 97% of contaminant from tapered needles and 65% from cutting needles, compared with the no-glove control data. Additional glove layers did not significantly improve contaminant removal from tapered needles (p > 0.05). For the cutting needle, 2 glove layers removed 91% of contaminant, which was significantly better than a single glove (p = 0.002). Three glove layers did not afford statistically significant additional protection (p = 0.122). There were no statistically significant differences between glove types (p = 0.41). With an aqueous needle contaminant, a single glove layer removes contaminant from tapered needles as effectively as multiple glove layers. For cutting needles, double-glove layering offers superior protection. There is no advantage to triple-glove layering. A surgeon should double-glove for maximum safety. Additionally, a surgeon should take advantage of other risk-reduction strategies, such as sharps safety, risk management, and use of sharpless instrumentation when possible.
Use of Traditional and Novel Methods to Evaluate the Influence of an EVA Glove on Hand Performance
NASA Technical Reports Server (NTRS)
Benson, Elizabeth A.; England, Scott A.; Mesloh, Miranda; Thompson, Shelby; ajulu, Sudhakar
2010-01-01
The gloved hand is one of an astronaut s primary means of interacting with the environment, and any restrictions imposed by the glove can strongly affect performance during extravehicular activity (EVA). Glove restrictions have been the subject of study for decades, yet previous studies have generally been unsuccessful in quantifying glove mobility and tactility. Past studies have tended to focus on the dexterity, strength, and functional performance of the gloved hand; this provides only a circumspect analysis of the impact of each type of restriction on the glove s overall capability. The aim of this study was to develop novel capabilities to provide metrics for mobility and tactility that can be used to assess the performance of a glove in a way that could enable designers and engineers to improve their current designs. A series of evaluations were performed to compare unpressurized and pressurized (4.3 psi) gloved conditions with the ungloved condition. A second series of evaluations were performed with the Thermal Micrometeoroid Garment (TMG) removed. This series of tests provided interesting insight into how much of an effect the TMG has on gloved mobility - in some cases, the presence of the TMG restricted glove mobility as much as pressurization did. Previous hypotheses had assumed that the TMG would have a much lower impact on mobility, but these results suggest that an improvement in the design of the TMG could have a significant impact on glove performance. Tactility testing illustrated the effect of glove pressurization, provided insight into the design of hardware that interfaces with the glove, and highlighted areas of concern. The metrics developed in this study served to benchmark the Phase VI EVA glove and to develop requirements for the next-generation glove for the Constellation program.
Zaatreh, Sarah; Enz, Andreas; Klinder, Annett; König, Tony; Mittelmeier, Lena; Kundt, Günther; Mittelmeier, Wolfram
2016-01-01
Introduction: Surgical gloves are used to prevent contamination of the patient and the hospital staff with pathogens. The aim of this study was to examine the actual effectiveness of gloves by examining the damage (perforations, tears) to latex gloves during surgery in the case of primary hip and knee prosthesis implantation. Materials and methods: Latex surgical gloves used by surgeons for primary hip and knee replacement surgeries were collected directly after the surgery and tested using the watertightness test according to ISO EN 455-1:2000. Results: 540 gloves were collected from 104 surgeries. In 32.7% of surgeries at least one glove was damaged. Of all the gloves collected, 10.9% were damaged, mainly on the index finger. The size of the perforations ranged from ≤1 mm to over 5 mm. The surgeon's glove size was the only factor that significantly influenced the occurrence of glove damage. Surgeon training level, procedure duration, and the use of bone cement had no significant influence. Conclusions: Our results highlight the high failure rate of surgical gloves. This has acute implications for glove production, surgical practice, and hygiene guidelines. Further studies are needed to detect the surgical steps, surface structures, and instruments that pose an increased risk for glove damage.
Gloves Reprocessing: Does It Really Save Money?
Arora, Pankaj; Kumari, Santosh; Sodhi, Jitender; Talati, Shweta; Gupta, Anil Kumar
2015-12-01
Gloves are reprocessed and reused in health-care facilities in resource-limited settings to reduce the cost of availability of gloves. The study was done with the aim to compute the cost of reprocessing of gloves so that an economically rationale decision can be taken. A retrospective record-based cross-sectional study was undertaken in a central sterile supply department where different steps during reprocessing of gloves were identified and the cost involved in reprocessing per pair of gloves was calculated. The cost of material and manpower was calculated to arrive at the cost of reprocessing per pair of gloves. The cost of a reprocessed pair of surgical gloves was calculated to be Indian Rupee (INR) 14.33 which was greater than the cost of a new pair of disposable surgical gloves (INR 9.90) as the cost of sterilization of one pair of gloves itself came out to be INR 10.97. The current study showed that the purchase of sterile disposable single-use gloves is cheaper than the process of recycling. Reprocessing of gloves is not economical on tangible terms even in resource-limited settings, and from the perspective of better infection control as well as health-care worker safety, it further justifies the use of disposable gloves.
Coupled Particle Transport and Pattern Formation in a Nonlinear Leaky-Box Model
NASA Technical Reports Server (NTRS)
Barghouty, A. F.; El-Nemr, K. W.; Baird, J. K.
2009-01-01
Effects of particle-particle coupling on particle characteristics in nonlinear leaky-box type descriptions of the acceleration and transport of energetic particles in space plasmas are examined in the framework of a simple two-particle model based on the Fokker-Planck equation in momentum space. In this model, the two particles are assumed coupled via a common nonlinear source term. In analogy with a prototypical mathematical system of diffusion-driven instability, this work demonstrates that steady-state patterns with strong dependence on the magnetic turbulence but a rather weak one on the coupled particles attributes can emerge in solutions of a nonlinearly coupled leaky-box model. The insight gained from this simple model may be of wider use and significance to nonlinearly coupled leaky-box type descriptions in general.
VITRIFICATION SYSTEM FOR THE TREATMENT OF PLUTONIUM-BEARING WASTE AT LOS ALAMOS NATIONAL LABORATORY
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. NAKAOKA; G. VEAZEY; ET AL
2001-05-01
A glove box vitrification system is being fabricated to process aqueous evaporator bottom waste generated at the Plutonium Facility (TA-55) at Los Alamos National Laboratory (LANL). The system will be the first within the U.S. Department of Energy Complex to routinely convert Pu{sup 239}-bearing transuranic (TRU) waste to a glass matrix for eventual disposal at the Waste Isolation Pilot Plant (WIPP). Currently at LANL, this waste is solidified in Portland cement. Radionuclide loading in the cementation process is restricted by potential radiolytic degradation (expressed as a wattage limit), which has been imposed to prevent the accumulation of flammable concentrations ofmore » H{sub 2} within waste packages. Waste matrixes with a higher water content (e.g., cement) are assigned a lower permissible wattage limit to compensate for their potential higher generation of H{sub 2}. This significantly increases the number of waste packages that must be prepared and shipped, thus driving up the costs of waste handling and disposal. The glove box vitrification system that is under construction will address this limitation. Because the resultant glass matrix produced by the vitrification process is non-hydrogenous, no H{sub 2} can be radiolytically evolved, and drums could be loaded to the maximum allowable limit of 40 watts. In effect, the glass waste form shifts the limiting constraint for loading disposal drums from wattage to the criticality limit of 200 fissile gram equivalents, thus significantly reducing the number of drums generated from this waste stream. It is anticipated that the number of drums generated from treatment of evaporator bottoms will be reduced by a factor of 4 annually when the vitrification system is operational. The system is currently undergoing non-radioactive operability testing, and will be fully operational in the year 2003.« less
NASA Astrophysics Data System (ADS)
Lestari, Brina Cindy; Dewi, Dyah Santhi; Widodo, Rusminto Tjatur
2017-11-01
The elderly who has a particular disease need to take some medicines in everyday with correct dosages and appropriate by time schedules. However, the elderly frequently forget to take medicines because of their memory weakened. Consequently, the product innovation of elderly healthcare is required for helping elderly takes some medicine more easily. This research aims to develop a smart medicine box by applying quality function deployment method. The first step is identifying elderly requirements through an ethnographic approach by interviewing thirty-two of elderly people as respondents. Then, the second step is translated elderly requirements to technical parameter for designing a smart medicine box. The smart box design is focused on two main requirements which have highest importance rating including alarm reminder for taking medicine and automatic medicine box. Finally, the prototype design has been created and tested by using usability method. The result shown that 90% from ten respondents have positive respond on the feature of smart medicine box. The voice of alarm reminder smart medicine box is easy to understand by elderly people for taking medicines.
The Development of a Design Database for the Computer Aided Prototyping System
1991-09-01
COMPUTER AIDED PROTOTYPING SYSTEM by Andrew Patrick Dwyer Captain, United States Marine Corps B.S., Juniata College, 1980 M.B.A. Webster University...Postgraduate School, Monterey, California, May 1990. Page-Jones, M., The Practical guide to Structured Systems Design, Yourdon Press, 1980 . Rumbaugh, J. and...United States Laboratory Command Army Research Office Attn: Dr. David Hislop P. 0. Box 12211 Research Triangle Park, NC 27709-2211 50. George Mason
Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration
Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.
2016-01-01
BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for better effectiveness for protecting the fingers. PMID:27867313
Glove perforations during open surgery for gynaecological malignancies.
Manjunath, A P; Shepherd, J H; Barton, D P J; Bridges, J E; Ind, T E J
2008-07-01
To audit glove perforations at laparotomies for gynaecological cancers. Gynaecological oncology unit, cancer centre, London. Prospective audit. Twenty-nine laparotomies for gynaecological cancers over 3 months. Gloves used during laparotomies for gynaecological cancer were tested for perforations by the air inflation and water immersion technique. Parameters recorded were: type of procedure, localisation of perforation, type of gloves, seniority of surgeon, operation time and awareness of perforations. Glove perforation rate. Perforations were found in gloves from 27/29 (93%) laparotomies. The perforation rate was 61/462 (13%) per glove. The perforation rate was three times higher when the duration of surgery was more than 5 hours. The perforation rate was 63% for primary surgeons, 54.5% for first assistant, 4.7% for second assistant and 40.5% for scrub nurses. Clinical fellows were at highest risk of injury (94%). Two-thirds of perforations were on the index finger or thumb. The glove on the nondominant hand had perforations in 54% of cases. In 50% of cases, the participants were not aware of the perforations. There were less inner glove perforations in double gloves compared with single gloves (5/139 versus 26/154; P = 0.0004, OR = 5.4, 95% CI 1.9-16.7). The indicator glove system failed to identify holes in 44% of cases. Glove perforations were found in most (93%) laparotomies for gynaecological malignancies. They are most common among clinical fellows, are often unnoticed and often not detected by the indicator glove system.
Influence of wearing latex gloves on electric pulp tester readings in children.
Holan, G
1993-12-01
Electric pulp testers operated by completing an electric circuit. Latex examination gloves have been claimed to interrupt this circuit and lead to false-negative results. This study was conducted to evaluate the influence of wearing latex gloves on electric pulp tester (EPT) readings. The pulps of 80 maxillary permanent incisors of 22 children 10-13 1/2 years old were tested using the Pelton & Crane 'Vitapulp' instrument. Each tooth was tested twice: with gloves and with bare hands. Teeth failing to respond to the EPT without gloves were excluded from the study. All EPT readings ranged between 1 and 9.5. Five teeth gave the same responses with gloved and ungloved hands. Only five teeth did not respond when gloves were worn, and all of these gave readings near the top of the EPT scale when tested without gloves. The other 70 teeth presented significantly higher readings with gloves than without gloves. It is concluded that removal of examination gloves during the operation of the EPT is necessary only if no response is obtained.
Methods for reducing energy dissipation in cosmetic gloves.
Herder, J L; Cool, J C; Plettenburg, D H
1998-06-01
For cosmetic reasons, hand prostheses are provided with cosmetic gloves. Their pleasing appearance, however, is accompanied by poor mechanical behavior, resulting in a negative influence on prosthesis operation. Glove stiffness is high and nonlinear, and internal friction in the glove material causes energy dissipation (hysteresis). In this article, two methods for reducing hysteresis in cosmetic gloves are proposed, that may be applied independently or in combination. Glove modification. Altering the mechanical properties of the glove itself is the first method that is presented. It was found possible to reduce both stiffness and hysteresis about 50% by forming grooves into the inside of the glove. Together with the evaluation of this method, several properties of the cosmetic glove were determined. Motion optimization. Additionally, a second method for reducing hysteresis was developed. The amount of hysteresis is influenced by the way the glove is forced to deform. The prosthesis mechanism, determining this deformation, was designed for minimum hysteresis and maximum cosmesis. For the prosthesis-glove combination used in this study, thumb motion optimization reduced hysteresis by about 65%.
The effects of vibration-reducing gloves on finger vibration
Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.
2015-01-01
Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new results and knowledge can be used to help select appropriate gloves for the operations of powered hand tools, to help perform risk assessment of the vibration exposure, and to help design better VR gloves. PMID:26543297
Comparison of nitrile gloves and nitrile over Nomex gloves.
Vorih, Deirdre Cronin; Bolton, Lauri D; Marcelynas, James; Nowicki, Thomas A; Jacobs, Lenworth; Robinson, Kenneth J
2009-01-01
Aeromedical flight crews must perform many tasks in flight requiring manual dexterity and fine precision. A common perception is that safety-enhancing fire-retardant gloves compromise patient care if worn during such tasks by providing added bulk and barrier to the hand. This study is a quantitative and qualitative analysis of this possible compromise to patient care. Sixteen practicing flight nurses and respiratory therapists were asked to perform 10 different standard patient care tasks while wearing either nitrile gloves or a nitrile-Nomex glove pair. Tasks were timed, rated as completed successfully or not, and were subsequently judged subjectively by the participants. Whereas the time required to insert an intravenous catheter and to insert a central line while wearing only nitrile gloves was significantly faster than when wearing both gloves, the time to perform all other tasks was not significantly different. In subjective ratings, the nitrile glove alone was scored significantly better than the two-glove combination by the study participants. Comfort, dexterity, tactile discrimination, and ease of use were all adversely affected by wearing a Nomex glove under a nitrile glove. Although the differences in times for most tasks may not be clinically significant, the difference in the subjective parameters may be great enough to cause helicopter emergency medical services (HEMS) practitioners to not wear Nomex gloves under nitrile gloves while performing procedures.
Series and parallel arc-fault circuit interrupter tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Jay Dean; Fresquez, Armando J.; Gudgel, Bob
2013-07-01
While the 2011 National Electrical Codeª (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by openingmore » the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.« less
NASA Technical Reports Server (NTRS)
Rajulu, Sudhakar; Benson, Elizabeth; England, Scott; Mesloh, Miranda; Thompson, Shelby
2009-01-01
The gloved hand is an astronaut s primary means of interacting with the environment, so performance on an EVA is strongly impacted by any restrictions imposed by the glove. As a result, these restrictions have been the subject of study for decades. However, previous studies have generally been unsuccessful in quantifying glove mobility and tactility. Instead, studies have tended to focus on the dexterity, strength and functional performance of the gloved hand. Therefore, it has been difficult to judge the impact of each type of restriction on the glove s overall capability. The lack of basic information on glove mobility in particular, is related to the difficulty in instrumenting a gloved hand to allow an accurate evaluation. However, the current study aims at developing novel technological capabilities to provide metrics for mobility and tactility that can be used to assess the performance of a glove in a way that could enable designers and engineers to improve upon their current designs. A series of evaluations were performed in ungloved, unpressurized and pressurized (4.3 psi) conditions, to allow a comparison across pressures and to the baseline barehanded condition. In addition, a subset of the testing was also performed with the Thermal Micrometeoroid Garment (TMG) removed. This test case in particular provided some interesting insight into how much of an impact the TMG has on gloved mobility -- in some cases, as much as pressurization of the glove. Previous rule-of-thumb estimates had assumed that the TMG would have a much lower impact on mobility, while these results suggest that an improvement in the TMG could actually have a significant impact on glove performance. Similarly, tactility testing illustrated the impact of glove pressurization on tactility and provided insight on the design of interfaces to the glove. The metrics described in this paper have been used to benchmark the Phase VI EVA glove and to develop requirements for the next generation glove for the Constellation program.
Erickson, Marilyn C; Liao, Jye-Yin; Webb, Cathy C; Habteselassie, Mussie Y; Cannon, Jennifer L
2018-02-02
Gloves are worn by workers harvesting ready-to-eat produce as a deterrent for contaminating the produce with enteric pathogens that may reside on their hands. As fields are not sterile environments, the probability for gloves to become contaminated still exists and therefore it is critical to understand the conditions that affect the survival of pathogens on gloves. Both Escherichia coli O157:H7 and Salmonella deposited on glove surfaces in a liquid state survived longer when the pathogen had been suspended in lettuce sap than when suspended in water. Despite this protection, pathogens deposited on clean single-use gloves were more likely to survive during drying than pathogens deposited on dirty gloves (a film of lettuce sap had been applied to the surface prior to pathogen application and soil had been ground into the gloves). Survival of both E. coli O157:H7 and Salmonella was biphasic with the greatest losses occurring during the first hour of drying followed by much slower losses in the ensuing hours. Pathogens grown in rich media (tryptic soy broth) versus minimal media (M9) as well as those cultured on solid agar versus liquid broth were also more likely to be resistant to desiccation when deposited onto gloves. Although survival of E. coli O157:H7 on nitrile gloves was in general greater than it was on latex gloves, the relative survival of Salmonella on the two glove types was inconsistent. Due to these inconsistencies, no one glove type is considered better than another in reducing the risk for contamination with enteric pathogens. In addition, the extended survival of what are generally referred to as stress-resistant pathogens suggests that gloves either be changed frequently during the day or washed in a disinfectant to reduce the risk of glove contamination that could otherwise contaminate product handled with the contaminated gloves. Copyright © 2017 Elsevier B.V. All rights reserved.
Testing of the box transformer 10/04.4 kV in the network of the electricity supply company
NASA Astrophysics Data System (ADS)
Cichowski, R.; Nickling, G.
1983-08-01
Applications of a 10/0.4 kV box transformer are studied. Single phase and triple phase prototypes were tested in a distribution network. Test results show that heat loss, hence ground desiccation danger is eliminated by using lean concrete as bedding material (ratio of weight sand: cement: water = 19:1:2). Redistribution of no-load losses and winding losses reduces the total loss from 460 to 324 W, and improves the connection technique.
Design and Test of Wendelstein 7-X Water-Cooled Divertor Scraper
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boscary, J.; Greuner, Henri; Ehrke, Gunnar
Heat load calculations have indicated the possible overloading of the ends of the water-cooled divertor facing the pumping gap beyond their technological limit. The intention of the scraper is the interception of some of the plasma fluxes both upstream and downstream before they reach the divertor surface. The scraper is divided into six modules of four plasma facing components (PFCs); each module has four PFCs hydraulically connected in series by two water boxes (inlet and outlet). A full-scale prototype of one module has been manufactured. Development activities have been carried out to connect the water boxes to the cooling pipesmore » of the PFCs by tungsten inert gas internal orbital welding. This prototype was successfully tested in the GLADIS facility with 17 MW/m2 for 500 cycles. The results of these activities have confirmed the possible technological basis for a fabrication of the water-cooled scraper.« less
Drug delivery by water-soluble organometallic cages.
Therrien, Bruno
2012-01-01
Until recently, organometallic derivatives were generally viewed as moisture- and air-sensitive compounds, and consequently very challenging to synthesise and very demanding in terms of laboratory requirements (Schlenk techniques, dried solvent, glove box). However, an increasing number of stable, water-soluble organometallic compounds are now available, and organometallic chemistry in aqueous phase is a flourishing area of research. As such, coordination-driven self-assemblies using organometallic building blocks are compatible with water, thus opening new perspectives in bio-organometallic chemistry.This chapter gives a short history of coordination-driven self-assembly, with a special attention to organometallic metalla-cycles, especially those composed of half-sandwich complexes. These metalla-assemblies have been used as sensors, as anticancer agents, as well as drug carriers.
Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions.
McDowell, Thomas W; Dong, Ren G; Welcome, Daniel E; Xu, Xueyan S; Warren, Christopher
2013-01-01
Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand-arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary: This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction.
Fundamentals of the knowledge about chemical additives present in rubber gloves.
Oliveira, Hegles Rosa de; Alchorne, Alice de Oliveira de Avelar
2011-01-01
One of the most frequent causes of allergic contact dermatitis of occupational origin are rubber additives, which are present in Personal Protective Equipment (PPE). The most allergenic additives of natural and synthetic gloves are thiurams, carbamates and mercapto group. To investigate the state of knowledge about the chemical additives used in the manufacture of synthetic rubber gloves. This was a qualitative research study in which professionals working in the manufacture, research, prescription and commercialization of gloves answered an open questionnaire. 30 individuals were interviewed: 4 researchers in occupational medicine, 5 occupational physicians, 2 occupational safety technicians, a rubber workers' union physician, an occupational safety engineer, a pro duction engineer of rubber gloves, 4 importers of gloves, a manufacturer of gloves, 3 businessmen who sell PPE, 3 salesclerks working in stores that sell PPE, 2 businessmen who own stores that sell products for allergic individuals, and 3 dermatologists. Knowledge of the chemical composition of rubber gloves is scant. The labeling of gloves, with the description of their chemical composition, would facilitate choosing the best type of glove for each person. This low-cost action to businesses would be a gain from the standpoint of public health, with huge repercussions for users of rubber gloves.
Rock, Clare; Harris, Anthony D; Reich, Nicholas G; Johnson, J Kristie; Thom, Kerri A
2013-11-01
Hand hygiene (HH) is recognized as a basic effective measure in prevention of nosocomial infections. However, the importance of HH before donning nonsterile gloves is unknown, and few published studies address this issue. Despite the lack of evidence, the World Health Organization and other leading bodies recommend this practice. The aim of this study was to assess the utility of HH before donning nonsterile gloves prior to patient contact. A prospective, randomized, controlled trial of health care workers entering Contact Isolation rooms in intensive care units was performed. Baseline finger and palm prints were made from dominant hands onto agar plates. Health care workers were then randomized to directly don nonsterile gloves or perform HH and then don nonsterile gloves. Postgloving finger and palm prints were then made from the gloved hands. Plates were incubated and colony-forming units (CFU) of bacteria were counted. Total bacterial colony counts of gloved hands did not differ between the 2 groups (6.9 vs 8.1 CFU, respectively, P = .52). Staphylococcus aureus was identified from gloves (once in "hand hygiene prior to gloving" group, twice in "direct gloving" group). All other organisms were expected commensal flora. HH before donning nonsterile gloves does not decrease already low bacterial counts on gloves. The utility of HH before donning nonsterile gloves may be unnecessary. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Lee, Hsiao-Shu; Lin, Yu-Wen
2009-04-01
Skin irritation and contact allergies are skin disorders common to hairdressers. The predominant oxidative hair dye components, such as p-phenylenediamine (PPD) and aminophenol isomers, can cause contact dermatitis. Use of protective gloves can prevent dermal contact with skin irritants. This study investigates the permeation behaviors of p-aminophenol (PAP), m-aminophenol (MAP), o-aminophenol (OAP) and PPD in single and mixed challenge solutions with disposable natural rubber latex (NRL) gloves, disposable polyvinylchloride (PVC) gloves and neoprene (NP) gloves. The challenge solutions were 4% PPD (w/v), 3% OAP (w/v), 2% PAP (w/v) and 2% MAP (w/v) in ethanol or 12% hydrogen peroxide solutions. The cocktail solutions of the four chemicals were also tested. An American Society for Testing and Materials type permeation cell, ethanol liquid collection and gas chromatography-flame ionization detection of samples taken from the collection medium every 10 min facilitated determination of breakthrough times (BTs), cumulative permeated masses and steady-state permeation rates (SSPRs). Experiments were 4 h long for the NRL and PVC gloves and 8 h for NP gloves. No chemicals tested broke through the NP gloves when exposed for 8 h. In the ethanol solution, PPD and OAP started breaking through the PVC gloves at 40 min. The SSPRs of PVC gloves were higher than those for NRL gloves in all challenge conditions for both single chemicals and mixtures. No tested chemicals in hydrogen peroxide solutions permeated the gloves during the 4-h tests. The chemical composition of the challenge solution was a main effecter of BTs and SSPRs for the NRL glove. For disposable PVC gloves, the main factors of BTs were molecular size [molar volume (MV)] and polarity (logK(ow)), and the primary factors of SSPRs were concentration, MV and logK(ow). In conclusion, disposable NRL gloves and disposable PVC gloves should not be used repeatedly for handling the hair dye products. Hydrogen peroxide did not accelerate chemical breakthrough. The compositions of the challenge solutions and physical and chemical properties (MV and logK(ow)) affected permeation behaviors for different gloves.
Malhotra, Monika; Sharma, Jai Bhagwan; Wadhwa, Leena; Arora, Raksha
2004-08-01
To assess the glove perforation rate, efficacy of double gloving, effect of duration of surgery, expertise of surgeon and operative urgency on the glove perforation rate in obstetrical and gynecologic operations. From February to September 2002, double glove protocol was made necessary for all major obstetrical and gynecologic procedures. The operating surgeon, first and second assistant were included in the study. Gloves damage was noted (overt by inspection, occult by hydroinsufflation technique). Of the 156 procedures included in study, 32 procedures were performed (all emergency operations) single-gloved because surgeons found double gloving clumsy (56%), made it difficult to tie knots due to lack of dexterity (24%), or were too tight (20%). One thousand one hundred and twenty single gloves were examined after each procedure by hydroinsufflation. The overall perforation rate was 13.6% (single versus double outer gloves, 13.8% versus l3.2%, P > 0.05). Matching perforations were found in six cases (4.6%). Thus, the protection offered by double gloves was 95.4% even if the outer gloves were perforated. Four inner gloves had preexisting perforations. Sixty unused gloves checked similarly revealed a perforation rate of 1.6%. Emergency cases had higher perforation rate compared to elective surgeries (16.6% versus 10.8%, P < 0.00 1). Surgeries lasting for more than 40 min had a higher perforation rate compared to those finished in less than or equal to 40 min (18.6% versus 7.6%, P < 0.001). The middle finger of the left hand was the most commonly involved. The surgeon, first assistant and second assistant were involved in 73.6, 23.3 and 3.2% cases, respectively. Double gloving offers considerable protection against exposure to contaminants in the blood and body fluids of the patient and should be made routine, especially in developing countries where HIV, hepatitis B and C are widely prevalent. Double gloving should be made mandatory in emergency procedures, which have a higher perforation rate due to operative urgency, and gloves should be changed in operations lasting for more than 40 min to ensure integrity of barrier.
Comparison of 4 different types of surgical gloves used for preventing blood contact.
Wittmann, Andreas; Kralj, Nenad; Köver, Jan; Gasthaus, Klaus; Lerch, Hartmut; Hofmann, Friedrich
2010-05-01
Needlestick injuries are always associated with a risk of infection, because these types of punctures may expose healthcare workers to a patient's blood and/or body fluids. To compare the efficacy of 4 different types of surgical gloves for preventing exposure to blood as a result of needlestick injury. For simulation of needlestick injury, a circular sample of pork skin was tightened onto a bracket, and a single finger from a medical glove was stretched over the sample. First, a powder-free surgical glove with a gel coating was used to test blood contact. Second, a glove with a patented puncture indication system was used to test blood contact with a double-gloved hand. Third, 2 powder-free latex medical gloves of the same size and hand were combined for double gloving, again to test blood contact. Finally, we tested a glove with an integrated disinfectant on the inside. The punctures were carried out using diverse sharp surgical devices that were contaminated with (99)Tc-marked blood. The amount of blood contact was determined from the transmitted radioactivity. For the powder-free surgical glove with a gel coating, a mean volume of 0.048 microL of blood (standard error of the mean [SEM], 0.077 microL) was transferred in punctures with an automated lancet at a depth of 2.4 mm through 1 layer of latex. For the glove with an integrated disinfectant on the inside, the mean volume of blood transferred was 0.030 microL (SEM, 0.0056 microL) with a single glove and was 0.024 microL (SEM, 0.003 microL) with 2 gloves. For the glove with the patented puncture indication system, a mean volume of 0.024 microL (SEM, 0.003 microL) of blood was transferred. Double gloving or the use of a glove with disinfectant can result in a decrease in the volume of blood transferred. Therefore, the use of either of these gloving systems could help to minimize the risk of bloodborne infections for medical staff.
NASA Astrophysics Data System (ADS)
Lee, Michael; Freed, Adrian; Wessel, David
1992-08-01
In this report we present our tools for prototyping adaptive user interfaces in the context of real-time musical instrument control. Characteristic of most human communication is the simultaneous use of classified events and estimated parameters. We have integrated a neural network object into the MAX language to explore adaptive user interfaces that considers these facets of human communication. By placing the neural processing in the context of a flexible real-time musical programming environment, we can rapidly prototype experiments on applications of adaptive interfaces and learning systems to musical problems. We have trained networks to recognize gestures from a Mathews radio baton, Nintendo Power GloveTM, and MIDI keyboard gestural input devices. In one experiment, a network successfully extracted classification and attribute data from gestural contours transduced by a continuous space controller, suggesting their application in the interpretation of conducting gestures and musical instrument control. We discuss network architectures, low-level features extracted for the networks to operate on, training methods, and musical applications of adaptive techniques.
Prior, Yeliz; Sutton, Chris; Cotterill, Sarah; Adams, Jo; Camacho, Elizabeth; Arafin, Nazina; Firth, Jill; O'Neill, Terence; Hough, Yvonne; Jones, Wendy; Hammond, Alison
2017-05-30
Arthritis gloves are regularly provided as part of the management of people with rheumatoid arthritis (RA) and undifferentiated (early) inflammatory arthritis (IA). Usually made of nylon and elastane (i.e. Lycra®), these arthritis gloves apply pressure with the aims of relieving hand pain, stiffness and improving hand function. However, a systematic review identified little evidence supporting their use. We therefore designed a trial to compare the effectiveness of the commonest type of arthritis glove provided in the United Kingdom (Isotoner gloves) (intervention) with placebo (control) gloves (i.e. larger arthritis gloves providing similar warmth to the intervention gloves but minimal pressure only) in people with these conditions. Participants aged 18 years and over with RA or IA and persistent hand pain will be recruited from National Health Service Trusts in the United Kingdom. Following consent, participants will complete a questionnaire booklet, then be randomly allocated to receive intervention or placebo arthritis gloves. Within three weeks, they will be fitted with the allocated gloves by clinical specialist rheumatology occupational therapists. Twelve weeks (i.e. the primary endpoint) after completing the baseline questionnaire, participants will complete a second questionnaire, including the same measures plus additional questions to explore adherence, benefits and problems with glove-wear. A sub-sample of participants from each group will be interviewed at the end of their participation to explore their views of the gloves received. The clinical effectiveness and cost-effectiveness of the intervention, compared to placebo gloves, will be evaluated over 12 weeks. The primary outcome measure is hand pain during activity. Qualitative interviews will be thematically analysed. This study will evaluate the commonest type of arthritis glove (Isotoner) provided in the NHS (i.e. the intervention) compared to a placebo glove. The results will help occupational therapists, occupational therapy services and people with arthritis make informed choices as to the value of arthritis gloves. If effective, arthritis gloves should become more widely available in the NHS to help people with RA and IA manage hand symptoms and improve performance of daily activities, work and leisure. If not, services can determine whether to cease supplying these to reduce service costs. ISRCTN Registry: ISRCTN25892131 Registered 05/09/2016.
[Old and new types of sanitary gloves: what has improved?].
Belleri, L; Crippa, Michela
2008-01-01
During the eighties a large increase in latex gloves production was observed because of the high demand of gloves in health care settings. In this period a low compliance to minimal quality standard was detected and the poor glove quality was associated with an increase of both irritant and allergic glove-related diseases. Since the second half of nineties health care workers and manufacturers paid more attention to these problems and a trend to a gradual, even if slow, quality improvement was observed. Most frequently powder-free gloves and synthetic gloves were offered on the market. The aim of this study was to highlight what has improved about materials and types of sanitary gloves during the last ten years. The information are based on a review of the scientific literature and practical experiences. Today a large selection of gloves made of different materials are available and they should be addressed to specific tasks. The review of the scientific literature and the analysis of many technical sheets provided by the manufacturers pointed out a trend to a better latex gloves quality (less chemical additives and generally a lower total protein content); sometimes data about a lower extractable latex allergens content are also available. Unfortunately detailed information on glove composition are not usually provided by the manufacturers; purchasers should require the manufacturing company to give comprehensive information and verify their reliability. Moreover the regulation in force should be adapted to higher quality standards. Powder-free and synthetic gloves consumption has improved but the use of synthetic rubber gloves should be further enhanced since some materials (e.g. neoprene and nitrile rubber) have a good biocompatibility and seem to have physical properties and protective efficacy similar to latex. Moreover allergic reactions to synthetic gloves (some chemical additives) are only occasional.
Bucknor, A; Karthikesalingam, A; Markar, SR; Holt, PJ; Jones, I; Allen-Mersh, TG
2010-01-01
INTRODUCTION The prudent selection of surgical gloves can deliver significant efficiency savings. However, objective data are lacking to compare differences in cutaneous sensibility between competing gloves. Therefore, the present study examined the use of a single comparable model of sterile surgical glove from two competing providers, Gammex PF HyGrip® (Ansell Limited, Red Bank, NJ, USA) with Biogel® (Mölnlycke Health Care AB, Göteborg, Sweden). SUBJECTS AND METHODS Cutaneous pressure threshold, static and moving two-point discrimination were measured as indices of objective surgical glove performance in 52 blinded healthcare professionals. RESULTS The mean cutaneous pressure threshold was 0.0680 ± 0.0923 g for skin, 0.411 ± 0.661 g for Ansell gloves and 0.472 ± 0.768 g for Biogel gloves. Skin was significantly more sensitive than Ansell (P< 0.0001) or Biogel (P< 0.0001) gloves (Wilcoxon signed rank test). There was no statistical difference between Biogel and Ansell gloves (P = 0.359). There was no significant difference between static or moving 2-point discrimination of skin and Ansell gloves (P= 0.556, P = 0.617; Wilcoxon signed rank test), skin and Biogel gloves (P= 0.486, P= 0.437; Wilcoxon signed rank test) or Ansell and Biogel gloves (P= 0.843, P= 0.670; Wilcoxon signed rank test). CONCLUSIONS No demonstrable objective difference was found between competing gloves in the outcome measures of cutaneous sensibility and two-point discrimination. However, a difference in subjective preference was noted. Untested factors may underlie this discrepancy, and further research should employ more sophisticated measurements of surgical performance using competing models of surgical glove. PMID:21118618
[Prevention of work-related latex allergy].
Mehlum, I S
1998-09-10
Latex allergy has become a common work-related disease among health care workers. An increase in the use of latex gloves is the main reason for this. Measures to prevent sensitization and allergic reactions to latex can be implemented at various administrative levels: at national and international levels by regulations and recommendations, and by the implementation of various measures at the place of work. When to use gloves and what gloves to use are important issues, balancing barrier properties and the need to prevent infection with the need to prevent sensitization and allergic reactions to latex. There are great variations between allergen levels in different gloves, and this can be measured in different ways. Threshold levels are not specified, and latex gloves should not be considered devoid of allergenic potential. The Norwegian Labour Inspection Authority has carried out a survey on latex gloves, based on information from manufacturers and importers, and present this survey to guide glove users. We recommend powder-free gloves with low levels of latex allergens/leachable proteins, chemicals and endotoxins. There are several low-allergen gloves available on the Norwegian market, but for some gloves we lack important information.
Permeability of latex gloves after contact with dental materials.
Richards, J M; Sydiskis, R J; Davidson, W M; Josell, S D; Lavine, D S
1993-09-01
The use of latex examination gloves in the dental office has become the standard of care. However, the effectiveness of gloves as a barrier after coming into contact with specific dental materials is still uncertain. To examine the effects of dental materials is still uncertain. To examine the effects of dental materials on latex, 100 latex examination glove finger tips were divided into 10 groups. Each group was manipulated in a different dental material for 15 minutes. Permeability was detected by the passage of herpes virus across the latex membrane, rinsed from the inner glove surface and titrated onto Vero cells. Significant virus leakage was discovered in gloves treated with acrylic monomer, chloroform, and orange solvent. Little virus leakage was noted in bleach, soap, and 30% phosphoric acid etchant treated gloves, and no virus leakage was found with composite resin, ethanol, formocresol, and water treated gloves. These data were supported with scanning electron micrographs taken of the treated glove samples and comparing with the controls. When certain dental materials are manipulated while wearing gloves, irreversible damage to the material occurs and may increase the practitioner's exposure to pathogens.
Glove perforations and blood contact associated with manipulation of the fetal scalp electrode.
Rhoton-Vlasak, A; Duff, P
1993-02-01
To assess prospectively the frequency of glove injury associated with insertion of the fetal scalp electrode and subsequent examination of the cervix with the electrode in place. Over a 7-month period, sterile gloves were collected after use for insertion of the fetal scalp electrode or cervical examination with the electrode in place. Attendants indicated their level of training, time, date and purpose of glove use, and cervical examination. They also noted whether they were aware of a glove perforation or observed blood, amniotic fluid, or genital tract secretions on their hand. Glove patency was assessed by filling the glove with water to 1.5-2.0 times its normal volume and observing for leaks. One hundred unused gloves were tested for patency and served as controls. Five hundred one gloves were evaluated, of which 13 (2.6%, 95% confidence interval [Cl] 1-4%) had perforations. Seven of 277 gloves (2.5%) used only for examinations had perforations, compared with six of 244 (2.5%) used only for insertion of the electrode. Two percent (95% CI 0-5%) of the unused control gloves had perforations. These observed differences were not statistically significant. Nineteen attendants (3.8%, 95% CI 2.1-5.5%) noted blood or genital tract secretions on their hand after insertion of the electrode (N = 4) or subsequent cervical examination (N = 15). Only one point of contract resulted from a glove perforation; the other 18 were on the wrist and apparently resulted from leakage of fluid around the open cuff of the glove. The risk of glove perforation during insertion of the fetal scalp electrode or subsequent cervical examination is low if proper technique is observed. Blood or fluid contact is more likely to result from leakage of fluid around the open cuff of the glove during a vaginal examination.
Glove and gown effects on intraoperative bacterial contamination.
Ward, William G; Cooper, Joshua M; Lippert, Dylan; Kablawi, Rawan O; Neiberg, Rebecca H; Sherertz, Robert J
2014-03-01
Experiments were performed to determine the risk of bacterial contamination associated with changing outer gloves and using disposable spunlace paper versus reusable cloth gowns. Despite decades of research, there remains a lack of consensus regarding certain aspects of optimal aseptic technique including outer glove exchange while double-gloving and surgical gown type selection. In an initial glove study, 102 surgical team members were randomized to exchange or retain outer gloves 1 hour into clean orthopedic procedures; cultures were obtained 15 minutes later from the palm of the surgeon's dominant gloved hand and from the surgical gown sleeve. Surgical gown type selection was recorded. A laboratory strike-through study investigating bacterial transmission through cloth and paper gowns was performed with coagulase-negative staphylococci. In a follow-up glove study, 251 surgical team members, all wearing paper gowns, were randomized as in the first glove study. Glove study 1 revealed 4-fold higher levels of baseline bacterial contamination (31% vs 7%) on the sleeve of surgical team members wearing cloth gowns than those using paper gowns [odds ratio (95% confidence interval): 4.64 (1.72-12.53); P = 0.0016]. The bacterial strike-through study revealed that 26 of 27 cloth gowns allowed bacterial transmission through the material compared with 0 of 27 paper gowns (P < 0.001). In glove study 2, surgeons retaining outer gloves 1 hour into the case had a subsequent positive glove contamination rate of 23% compared with 13% among surgeons exchanging their original outer glove [odds ratio (95% confidence interval): 1.97 (1.02-3.80); P = 0.0419]. Paper gowns demonstrated less bacterial transmission in the laboratory and lower rates of contamination in the operating room. Disposable paper gowns are recommended for all surgical cases, especially those involving implants, because of the heightened risk of infection. Outer glove exchange just before handling implant materials is also recommended to minimize intraoperative contamination.
ERIC Educational Resources Information Center
Maule, R. William
1994-01-01
Discusses prototype information infrastructure projects in northern California's Silicon Valley. The strategies of the public and private telecommunications carriers vying for backbone services and industries developing end-user infrastructure technologies via office networks, set-top box networks, Internet multimedia, and "smart homes"…
Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions
McDowell, Thomas W.; Dong, Ren G.; Welcome, Daniel E.; Xu, Xueyan S.; Warren, Christopher
2015-01-01
Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand–arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction. PMID:24160755
Mechanical counter-pressure vs. gas-pressurized spacesuit gloves: grip and sensitivity.
Danaher, Patrick; Tanaka, Kunihiko; Hargens, Alan R
2005-04-01
An elastic mechanical counter pressure (MCP) glove for spacesuits is under development. In this study we compared handgrip and pinch grip strength levels for the MCP glove and the current extravehicular mobility unit (EMU) gas-pressurized glove. We employed handgrip and pinch grip dynamometers to assess strength levels and von Frey monofilaments to evaluate hand sensitivity. Tests were conducted with the gloved hand inserted in an evacuation chamber at 200 mmHg below atmospheric pressure to simulate conditions in space. Average bare hand strength was 463 N and decreased to 240 N for EMU and 250 N for MCP. Pinch grip and key grip testing showed no difference among conditions. However, there was a significant decrease in palmar grip strength from 111 N barehanded to 67 N in both gloves. Barehanded endurance time was 160 s and dropped to 63 and 69 s for EMU and MCP, respectively. Sensitivity was significantly better for MCP compared with the EMU. The MCP glove improved hand sensitivity when compared with the EMU glove and performed as well as the EMU glove in terms of overall handgrip strength, endurance at 25% of maximum handgrip strength, pinch grip, palmar grip, and key grip tests. Improvements in fabric composition and glove design may further improve ergonomic and other functional parameters of the MCP glove.
Surgical glove perforation in cardiac surgery.
Driever, R; Beie, M; Schmitz, E; Holland, M; Knapp, M; Reifschneider, H J; Hofmann, F; Vetter, H O
2001-12-01
Recently, concern for the protection of health care employees and health care recipients has led to increasing awareness of transmitted infections. Sterile surgical gloves were tested to determine the incidence of perforations after being worn during procedures commonly performed by cardiac surgeons. In a prospective study conducted from January 15, 2000 through February 15, 2000, 953 gloves worn during cardiac surgery were evaluated for punctures. Pairs of sterile latex surgical gloves were collected over a period of one month. Routine tasks included mainly bypass and valve surgery. Impermeability was tested by means of a water retention test according to European standard EN 455 Part 1 performed on 954 (Manufix, Hartmann, Germany) latex gloves. A control group of 50 unused gloves was also evaluated for the presence of spontaneous leakage. Gloves were separated according to whether the wearer was an operator (254 gloves), first assistant (220 gloves), second assistant (272 gloves), or theatre nurse (207 gloves). Gloves with a known perforation occurring during the procedure were not included in the study. There were no punctures in the 50 unused gloves. Punctures were detected in 66 of 254 (26.0 %) gloves used by operators, 49 of 220 (22.3 %) used by first assistants, 25 of 272 (9.2 %) used by second assistants, and 78 of 207 (37.7 %) used by theatre nurses. Some gloves had more than one puncture, accounting for the 244 holes detected (operators 75/244 = 30.7 %; first assistants 54/244 = 22.1 %; second assistants 28/244 = 11.5 %; theatre nurses 87/244 = 35.7 %). Sites of scalpel and suture needle injuries were most commonly the thumb (27.3 %) and pointer finger (42.1 %) of the non-dominant hand, followed by, in descending order: middle finger (10.2 %), other fingers (15.7 %), palm (3.8 %) and back of the hand (0.9 %). The number of punctures that occur during cardiac operations is obviously higher than has so far been assumed. Therefore, cardiac surgeons should consider the incidence of unknown glove perforations when planning surgery in patients with infectious diseases.
Permeability of different types of medical protective gloves to acrylic monomers.
Lönnroth, Emma-Christin; Wellendorf, Hanne; Ruyter, Eystein
2003-10-01
Dental personnel and orthopedic surgeons are at risk when manually handling products containing methyl methacrylate (MMA). Dental products may also contain cross-linking agents such as ethylene glycol dimethacrylate (EGDMA) or 1,4-butanediol dimethacrylate (1,4-BDMA). Skin contact with monomers can cause hand eczema, and the protection given by gloves manufactured from different types of material is not well known. The aim of this study was to determine the breakthrough time (BTT, min) as a measure of protection (according to the EU standard EN-374-3) for a mixture consisting of MMA, EGDMA and 1,4-BDMA. Fifteen different gloves representing natural rubber latex material, synthetic rubber material (e.g. nitrile rubbers), and synthetic polymer material were tested. The smallest monomer MMA permeated within 3 min through all glove materials. A polyethylene examination glove provided the longest protection period to EGDMA and 1, 4-BDMA (> 120 min and 25.0 min), followed by the surgical glove Tactylon (6.0 min and 8.7 min) and the nitrile glove Nitra Touch (5.0 min and 8.7 min). This study showed that the breakthrough time (based on permeation rate) cannot be regarded as a 'safe limit'. When the permeation rate is low, monomers may have permeated before BTT can be determined. Using double gloves with a synthetic rubber inner glove and a natural rubber outer glove provided longer protection when the inner glove was rinsed in water before placing the outer glove on top.
Firefighter Hand Anthropometry and Structural Glove Sizing: A New Perspective.
Hsiao, Hongwei; Whitestone, Jennifer; Kau, Tsui-Ying; Hildreth, Brooke
2015-12-01
We evaluated the current use and fit of structural firefighting gloves and developed an improved sizing scheme that better accommodates the U.S. firefighter population. Among surveys, 24% to 30% of men and 31% to 62% of women reported experiencing problems with the fit or bulkiness of their structural firefighting gloves. An age-, race/ethnicity-, and gender-stratified sample of 863 male and 88 female firefighters across the United States participated in the study. Fourteen hand dimensions relevant to glove design were measured. A cluster analysis of the hand dimensions was performed to explore options for an improved sizing scheme. The current national standard structural firefighting glove-sizing scheme underrepresents firefighter hand size range and shape variation. In addition, mismatch between existing sizing specifications and hand characteristics, such as hand dimensions, user selection of glove size, and the existing glove sizing specifications, is significant. An improved glove-sizing plan based on clusters of overall hand size and hand/finger breadth-to-length contrast has been developed. This study presents the most up-to-date firefighter hand anthropometry and a new perspective on glove accommodation. The new seven-size system contains narrower variations (standard deviations) for almost all dimensions for each glove size than the current sizing practices. The proposed science-based sizing plan for structural firefighting gloves provides a step-forward perspective (i.e., including two women hand model-based sizes and two wide-palm sizes for men) for glove manufacturers to advance firefighter hand protection. © 2015, Human Factors and Ergonomics Society.
2013-11-27
SECURITY CLASSIFICATION OF: CUBRC has developed an in-line, multi-analyte isolation technology that utilizes solid phase extraction chemistries to purify...goals. Specifically, CUBRC will design and manufacture a prototype cartridge(s) and test the prototype cartridge for its ability to isolate each...display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. CUBRC , Inc. P. O. Box 400 Buffalo, NY 14225 -1955
Aircraft energy efficiency laminar flow control glove flight conceptual design study
NASA Technical Reports Server (NTRS)
Wright, A. S.
1979-01-01
A laminar flow control glove applied to the wing of a short to medium range jet transport with aft mounted engines was designed. A slotted aluminum glove concept and a woven stainless steel mesh porous glove concept suction surfaces were studied. The laminar flow control glove and a dummy glove with a modified supercritical airfoil, ducting, modified wing leading and trailing edges, modified flaps, and an LFC trim tab were applied to the wing after slot spacing suction parameters, and compression power were determined. The results show that a laminar flow control glove can be applied to the wing of a jet transport with an appropriate suction system installed.
Antimicrobial allergy from polyvinyl chloride gloves.
Aalto-Korte, Kristiina; Alanko, Kristiina; Henriks-Eckerman, Maj-Len; Jolanki, Riitta
2006-10-01
Contact allergy to plastic gloves is rare. Benzisothiazolinone is a biocide that is mainly used in industrial settings. We first suspected delayed-type contact allergy to benzisothiazolinone from polyvinyl chloride (PVC) gloves in 2004. We looked through our medical records from 1991 to 2005 to find similar cases. We found a total of 8 patients who are allergic to benzisothiazolinone and who had had exacerbations of their hand dermatitis while using PVC gloves. Patch testing revealed that 3 of them had weak allergic or doubtful reactions to the glove materials. Six of them had used Evercare Soft, Medi-Point, or Derma Grip PVC gloves, which in chemical analysis were shown to contain 9 to 32 ppm of benzisothiazolinone. Seven of the patients worked in dentistry or health care and 1 in farming. All of them had had hand dermatitis for many years. To our knowledge, there have been no previous reports of contact allergy to antimicrobial agents in plastic gloves. Benzisothiazolinone is widely used as a biocide in the manufacture of disposable PVC gloves. Small amounts of benzisothiazolinone in the gloves may sensitize those who already have hand dermatitis. We recommend that all patients with hand dermatitis while using PVC gloves should be patch tested with benzisothiazolinone.
Gill, C O; Jones, T
2002-06-01
On eight occasions, five volunteers each handled five pieces of meat with bare hands or while wearing dry or wet knitted gloves or rubber gloves after hands had been inoculated with Escherichia coli or after handling a piece of meat inoculated with E. coli. On each occasion, after all meat was handled, each piece of meat, glove, and hand were sampled to recover E. coli. When hands were inoculated, E. coli was recovered from all meat handled with bare hands, in lesser numbers from some pieces handled with knitted gloves, and from only one piece handled with rubber gloves. When pieces of inoculated meat were handled, the numbers of E. coli transferred to uninoculated meat from bare hands or rubber gloves decreased substantially with each successive piece of uninoculated meat, but decreases were small with knitted gloves. The findings indicate that, compared with bare hands, the use of knitted gloves could reduce the transfer of bacteria from hands to meat but could increase the transfer of bacteria between meat pieces, whereas the use of rubber gloves could largely prevent the first and greatly reduce the second type of bacteria transfer.
Evaluating Utility Gloves as a Potential Reservoir for Pathogenic Bacteria.
Grant, Kathy L; Naber, E Donald; Halteman, William A
2015-08-01
This pilot study sought to determine the rate and degree to which gram-negative Klebsiella pneumoniae, Escherichia coli and Pseudomonas aeruginosa and gram-positive Staphylococcus aureus occurred on the inside of utility gloves used at University of Maine at Augusta, Dental Health Programs' dental hygiene clinic. Five steam autoclave utility gloves were randomly selected to serve as control and a convenience sample of 10 used utility gloves were selected from the sterilization area. A sample was collected from a predetermined surface area from the inside of each steam autoclave utility glove and used utility glove. Each sample was used to inoculate a Petri plate containing 2 types of culture media. Samples were incubated at 37° C for 30 to 36 hours in aerobic conditions. Colony forming units (CFU) were counted. Confidence intervals (CI) estimated the rate of contamination with gram-negative K. pneumoniae, E. coli and P. aeruginosa on the inside of steam autoclave utility gloves to be n=33 95% CL [0.000, 0.049], used utility gloves to be n=70, 95% CL [0.000, 0.0303]. Data estimated the rate of contamination with gram-positive S. aureus on the inside of steam autoclave utility gloves to be n=35, 95% CL [0.233, 0.530], used utility gloves to be n=70, 95% CL [0.2730, 0.4975]. Culture media expressed a wide range of CFU from 0 to over 200. The risk of utility glove contamination with gram-negative bacteria is likely low. The expressed growth of S. aureus from steam autoclave utility gloves controls raises questions about the effectiveness and safety of generally accepted sterilization standards for the governmentally mandated use of utility gloves. Copyright © 2015 The American Dental Hygienists’ Association.
Investigation of X-ray permeability of surgical gloves coated with different contrast agents
Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel
2016-01-01
Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548
Dexterity test data contribute to reduction in leaded glovebox gloves use
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cournoyer, Michael E; Lawton, Cindy M; Castro, Amanda M
2009-01-01
Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (T A-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Using an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management who own glovebox processes through this program make decisions onmore » which type of glovebox gloves (hereafter referred to as gloves), the weakest component of this safety-significant system, would perform best in these aggressive environments. As Low as Reasonably Achievable considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) gloves made from Hypalon(reg.) were the primary glove for programmatic operations at TA55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduce the amount of mixed transuranic waste. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the pros and cons of wearing leaded gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and the pollution prevention benefits of this dramatic change in the glovebox system are presented.« less
Ravikumar, C M; Sangur, Rajashekar
2012-01-01
Addition silicone impression materials have been used as impression material for more than 20 years. Although they are among the most expensive impression materials, they became popular during the past decade as they have excellent physical properties. Prevention of infection is an important aspect in dental treatment since dental professionals are routinely exposed to the wide variety of microorganisms present in saliva. Gloves are the most common protective measure used during dental treatment. The gloves are mostly made of latex. In this study, we examine how the setting time of three types polyvinyl putty materials were affected by the use of five different brands of latex gloves and one brand of vinyl gloves. Each material was first mixed without wearing gloves according to the manufacturer's instructions. After the stipulated mixing time, the setting time was measured using the Vicat needle. The setting time is measured from the time of mixing till the time that the needle does not produce any indentation on the surface of the material. The putty material was then mixed with gloved hands (using the five different brands of latex gloves in turn) and the setting time was measured. Then the material was mixed with washed gloved hands, and the setting time was measured again. Finally, the material was mixed with vinyl gloved hands and the setting time was measured. The following conclusions were drawn from the study: Reprosil and Express showed significant variation in the setting time with the latex gloved hands.There was no significant variation in the setting time when material was mixed with unwashed vs washed gloved hands.Vinyl gloves did not significantly affect the setting time of any of the putty impression materials.
RoboGlove: Initial Work Toward a Robotically Assisted EVA Glove
NASA Technical Reports Server (NTRS)
Rogers, Jonathan
2015-01-01
The RoboGlove is a device designed to provide additional grip strength or endurance for a user. In applying this Robonaut 2 spinoff technology to the Phase VI Space Suit glove, the project is using robotic tendons and actuators to regain some of the hand performance that is lost when wearing a pressurized glove. An array of sensors embedded into the finger softgoods provides input to the control system which retracts the tendons, helping to close the user's hand. While active, this system provides augmentation, but is nonintrusive to glove usage when disabled.
Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P
2018-01-01
The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused amplification of handle vibration at the fingers. The fingers' vibration transmission performance of gloves were further evaluated using a proposed finger frequency-weighting W f apart from the standardized W h -weighting. It is shown that the W h weighting generally overestimates the VR glove effectiveness in limiting the fingers vibration in the high (H: 200-1250 Hz) frequency range. Both the weightings, however, revealed comparable performance of gloves in the mid (M: 25-200 Hz) frequency range. The VR gloves, with the exception of the leather glove, showed considerable reductions in the grip strength (27-41%), while the grip strength reduction was not correlated with the glove material thickness. It is suggested that effectiveness of VR gloves should be assessed considering the vibration transmission to both the palm and fingers of the hand together with the hand grip strength reduction. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mathews, Airek R; Que Hee, Shane S
2017-04-01
The aim was to develop a whole glove permeation method for cyclohexanol to generate permeation parameter data for a non-moving dextrous robot hand (normalized breakthrough time t b , standardized breakthrough time t s , steady state permeation rate P s , and diffusion coefficient D). Four types of disposable powderless, unsupported, and unlined nitrile gloves from the same producer were investigated: Safeskin Blue and Kimtech Science Blue, Purple, and Sterling. The whole glove method developed involved a peristaltic pump for water circulation through chemically resistant Viton tubing to continually wash the inner surface of the test glove via holes in the tubing, a dextrous robot hand operated by a microprocessor, a chemically protective nitrile glove to protect the robot hand, an incubator to maintain 35°C temperature, and a hot plate to maintain 35°C at the sampling point of the circulating water. Aliquots of 1.0 mL were sampled at regular time intervals for the first 60 min followed by removal of 0.5 mL aliquots every hour to 8 hr. Quantification was by the internal standard method after gas chromatography-selective ion electron impact mass spectrometry using a non-polar capillary column. The individual glove values of t b and t s differed for the ASTM closed loop method except for Safeskin Blue, but did not for the whole glove method. Most of the kinetic parameters agreed within an order of magnitude for the two techniques. The order of most protective to least protective glove was Blue and Safeskin, then Purple followed by Sterling for the whole gloves. The analogous order for the modified F739 ASTM closed loop method was: Safeskin, Blue, Purple, and Sterling, almost the same as for the whole glove. The Sterling glove was "not recommended" from the modified ASTM data, and was "poor" from the whole glove data.
Edmiston, Charles E; Zhou, S Steve; Hoerner, Pierre; Krikorian, Raffi; Krepel, Candace J; Lewis, Brian D; Brown, Kellie R; Rossi, Peter J; Graham, Mary Beth; Seabrook, Gary R
2013-02-01
Percutaneous injuries associated with cutting instruments, needles, and other sharps (eg, metallic meshes, bone fragments, etc) occur commonly during surgical procedures, exposing members of surgical teams to the risk for contamination by blood-borne pathogens. This study evaluated the efficacy of an innovative integrated antimicrobial glove to reduce transmission of the human immunodeficiency virus (HIV) following a simulated surgical-glove puncture injury. A pneumatically activated puncturing apparatus was used in a surgical-glove perforation model to evaluate the passage of live HIV-1 virus transferred via a contaminated blood-laden needle, using a reference (standard double-layer glove) and an antimicrobial benzalkonium chloride (BKC) surgical glove. The study used 2 experimental designs. In method A, 10 replicates were used in 2 cycles to compare the mean viral load following passage through standard and antimicrobial gloves. In method B, 10 replicates were pooled into 3 aliquots and were used to assess viral passage though standard and antimicrobial test gloves. In both methods, viral viability was assessed by observing the cytopathic effects in human lymphocytic C8166 T-cell tissue culture. Concurrent viral and cell culture viability controls were run in parallel with the experiment's studies. All controls involving tissue culture and viral viability were performed according to study design. Mean HIV viral loads (log(10)TCID(50)) were significantly reduced (P < .01) following passage through the BKC surgical glove compared to passage through the nonantimicrobial glove. The reduction (log reduction and percent viral reduction) of the HIV virus ranged from 1.96 to 2.4 and from 98.9% to 99.6%, respectively, following simulated surgical-glove perforation. Sharps injuries in the operating room pose a significant occupational risk for surgical practitioners. The findings of this study suggest that an innovative antimicrobial glove was effective at significantly (P < .01) reducing the risk for blood-borne virus transfer in a model of simulated glove perforation. Copyright © 2013 Mosby, Inc. All rights reserved.
Todd, Ewen C D; Michaels, Barry S; Greig, Judy D; Smith, Debra; Bartleson, Charles A
2010-09-01
The role played by food workers and other individuals in the contamination of food has been identified as an important contributing factor leading to foodborne outbreaks. To prevent direct bare hand contact with food and food surfaces, many jurisdictions have made glove use compulsory for food production and preparation. When properly used, gloves can substantially reduce opportunities for food contamination. However, gloves have limitations and may become a source of contamination if they are punctured or improperly used. Experiments conducted in clinical and dental settings have revealed pinhole leaks in gloves. Although such loss of glove integrity can lead to contamination of foods and surfaces, in the food industry improper use of gloves is more likely than leakage to lead to food contamination and outbreaks. Wearing jewelry (e.g., rings) and artificial nails is discouraged because these items can puncture gloves and allow accumulation of microbial populations under them. Occlusion of the skin during long-term glove use in food operations creates the warm, moist conditions necessary for microbial proliferation and can increase pathogen transfer onto foods through leaks or exposed skin or during glove removal. The most important issue is that glove use can create a false sense of security, resulting in more high-risk behaviors that can lead to cross-contamination when employees are not adequately trained.
PCR-Based Method for Detecting Viral Penetration of Medical Exam Gloves
Broyles, John M.; O'Connell, Kevin P.; Korniewicz, Denise M.
2002-01-01
The test approved by the U.S. Food and Drug Administration for assessment of the barrier quality of medical exam gloves includes visual inspection and a water leak test. Neither method tests directly the ability of gloves to prevent penetration by microorganisms. Methods that use microorganisms (viruses and bacteria) to test gloves have been developed but require classical culturing of the organism to detect it. We have developed a PCR assay for bacteriophage φX174 that allows the rapid detection of penetration of gloves by this virus. The method is suitable for use with both latex and synthetic gloves. The presence of glove powder on either latex or synthetic gloves had no effect on the ability of the PCR assay to detect bacteriophage DNA. The assay is rapid, sensitive, and inexpensive; requires only small sample volumes; and can be automated. PMID:12149320
Investigation of the effects of extravehicular activity (EVA) gloves on performance
NASA Technical Reports Server (NTRS)
Bishu, Ram R.; Klute, Glenn
1993-01-01
The objective was to assess the effects of extravehicular activity (EVA) gloves at different pressures on human hand capabilities. A factorial experiment was performed in which three types of EVA gloves were tested at five pressure differentials. The independent variables tested in this experiment were gender, glove type, pressure differential, and glove make. Six subjects participated in an experiment where a number of dexterity measures, namely time to tie a rope, and the time to assemble a nut and bolt were recorded. Tactility was measured through a two point discrimination test. The results indicate that with EVA gloves strength is reduced by nearly 50 percent, there is a considerable reduction in dexterity, performance decrements increase with increasing pressure differential, and some interesting gender glove interactions were observed, some of which may have been due to the extent (or lack of) fit of the glove to the hand. The implications for the designer are discussed.
Assessment of Protective Gloves for Use with Airfed Suits
Millard, Claire E.
2015-01-01
Gloves are often needed for hand protection at work, but they can impair manual dexterity, especially if they are multilayered or ill-fitting. This article describes two studies of gloves to be worn with airfed suits (AFS) for nuclear decommissioning or containment level 4 (CL4) microbiological work. Both sets of workers wear multiple layers of gloves for protection and to accommodate decontamination procedures. Nuclear workers are also often required to wear cut-resistant gloves as an extra layer of protection. A total of 15 subjects volunteered to take part in manual dexterity testing of the different gloving systems. The subjects’ hands were measured to ensure that the appropriate sized gloves were used. The gloves were tested with the subjects wearing the complete clothing ensembles appropriate to the work, using a combination of standard dexterity tests: the nine-hole peg test; a pin test adapted from the European Standard for protective gloves, the Purdue Pegboard test, and the Minnesota turning test. Specialized tests such as a hand tool test were used to test nuclear gloves, and laboratory-type manipulation tasks were used to test CL4 gloves. Subjective assessments of temperature sensation and skin wettedness were made before and after the dexterity tests of the nuclear gloves only. During all assessments, we made observations and questioned the subjects about ergonomic issues related to the clothing ensembles. Overall, the results show that the greater the thickness of the gloves and the number of layers the more the levels of manual dexterity performance are degraded. The nuclear cut-resistant gloves with the worst level of dexterity were stiff and inflexible and the subjects experienced problems picking up small items and bending their hands. The work also highlighted other factors that affect manual dexterity performance, including proper sizing, interactions with the other garments worn at the time, and the work equipment in use. In conclusion, when evaluating gloves for use in the workplace it is important to use tests that reflect the working environment and always to consider the balance between protection and usability. PMID:26272645
Beránková, Martina; Hojerová, Jarmila; Peráčková, Zuzana
2017-11-01
Exposure of handlers'/operators' hands is a main route of agricultural pesticides entry into their body. Non-occupational handlers still lack information about appropriate selection of protective gloves to minimize exposure and reduce adverse effects of these chemicals. According to the results of our previous survey, six commercially available, water-resistant gloves commonly used by non-professional gardeners were evaluated for permeation of Acetamiprid, Pirimicarb, and Chlorpyrifos-methyl (Chlorp-m) pesticides by means of in vitro testing. In-use conditions were mimicked as close as possible. Chlorp-m through latex was observed inside the glove from >10 to ⩽15 min; however, Acetamiprid and Pirimicarb through neoprene/latex and all the three pesticides through butyl were not observed inside gloves for the duration of the experiments (the Breakthrough time (BT)>8 h). The 1-h exposure proved the interior glove contamination with Chlorp-m through disposable latex, vinyl, and nitrile gloves (51, 33, and 41% of applied dose (AD), respectively) just as with Acetamiprid and Pirimicarb through latex glove (11 and 14%AD, respectively). However, when storing the used gloves for 4 days after the exposure, no release of the three pesticides from the butyl and Acetamiprid from neoprene/latex gloves was detected. In all other cases, pesticides were found in the interior glove (36-79, 31-63, and 51-81%AD for Acetamiprid, Pirimicarb, and Chlorp-m, respectively). If used repeatedly, gloves contaminated in this way lose their protective function but give the user a false sense of security. The results suggest that (i) water-resistant gloves are not necessarily pesticide resistant; (ii) disposable latex gloves commonly worn by non-professional gardeners provide inadequate protection even for a short-time contact with pesticides; (iii) to assess the efficiency of reusable gloves, not only BT value but also the reservoir/release effect of parent pesticide and its degradation products should be evaluated; and (iv) awareness-raising activities for non-occupational handlers of pesticides should be enhanced.
Assessment of Protective Gloves for Use with Airfed Suits.
Millard, Claire E; Vaughan, Nicholas P
2015-10-01
Gloves are often needed for hand protection at work, but they can impair manual dexterity, especially if they are multilayered or ill-fitting. This article describes two studies of gloves to be worn with airfed suits (AFS) for nuclear decommissioning or containment level 4 (CL4) microbiological work. Both sets of workers wear multiple layers of gloves for protection and to accommodate decontamination procedures. Nuclear workers are also often required to wear cut-resistant gloves as an extra layer of protection. A total of 15 subjects volunteered to take part in manual dexterity testing of the different gloving systems. The subjects' hands were measured to ensure that the appropriate sized gloves were used. The gloves were tested with the subjects wearing the complete clothing ensembles appropriate to the work, using a combination of standard dexterity tests: the nine-hole peg test; a pin test adapted from the European Standard for protective gloves, the Purdue Pegboard test, and the Minnesota turning test. Specialized tests such as a hand tool test were used to test nuclear gloves, and laboratory-type manipulation tasks were used to test CL4 gloves. Subjective assessments of temperature sensation and skin wettedness were made before and after the dexterity tests of the nuclear gloves only. During all assessments, we made observations and questioned the subjects about ergonomic issues related to the clothing ensembles. Overall, the results show that the greater the thickness of the gloves and the number of layers the more the levels of manual dexterity performance are degraded. The nuclear cut-resistant gloves with the worst level of dexterity were stiff and inflexible and the subjects experienced problems picking up small items and bending their hands. The work also highlighted other factors that affect manual dexterity performance, including proper sizing, interactions with the other garments worn at the time, and the work equipment in use. In conclusion, when evaluating gloves for use in the workplace it is important to use tests that reflect the working environment and always to consider the balance between protection and usability. © Crown copyright 2015.
Firefighter Hand Anthropometry and Structural Glove Sizing: A New Perspective
Hsiao, Hongwei; Whitestone, Jennifer; Kau, Tsui-Ying; Hildreth, Brooke
2015-01-01
Objective We evaluated the current use and fit of structural firefighting gloves and developed an improved sizing scheme that better accommodates the U.S. firefighter population. Background Among surveys, 24% to 30% of men and 31% to 62% of women reported experiencing problems with the fit or bulkiness of their structural firefighting gloves. Method An age-, race/ethnicity-, and gender-stratified sample of 863 male and 88 female firefighters across the United States participated in the study. Fourteen hand dimensions relevant to glove design were measured. A cluster analysis of the hand dimensions was performed to explore options for an improved sizing scheme. Results The current national standard structural firefighting glove-sizing scheme underrepresents firefighter hand size range and shape variation. In addition, mismatch between existing sizing specifications and hand characteristics, such as hand dimensions, user selection of glove size, and the existing glove sizing specifications, is significant. An improved glove-sizing plan based on clusters of overall hand size and hand/finger breadth-to-length contrast has been developed. Conclusion This study presents the most up-to-date firefighter hand anthropometry and a new perspective on glove accommodation. The new seven-size system contains narrower variations (standard deviations) for almost all dimensions for each glove size than the current sizing practices. Application The proposed science-based sizing plan for structural firefighting gloves provides a step-forward perspective (i.e., including two women hand model–based sizes and two wide-palm sizes for men) for glove manufacturers to advance firefighter hand protection. PMID:26169309
Mobility of an elastic glove for extravehicular activity without prebreathing.
Tanaka, Kunihiko; Ikeda, Mizuki; Mochizuki, Yosuke; Katafuchi, Tetsuro
2011-09-01
The current U.S. extravehicular activity (EVA) suit is pressurized at 0.29 atm, which is much lower than the pressures of sea level and inside a space station. Higher pressure can reduce the risk of decompression sickness (DCS), but mobility would be sacrificed. We have demonstrated that a glove and sleeve made of elastic material increased mobility when compared with those made of nonelastic material, such as that found in the current suit. We hypothesized that an elastic glove of 0.65 atm that has no risk of DCS also has greater mobility compared with a non-elastic glove of 0.29 atm. The right hands of 10 healthy volunteers were studied in a chamber with their bare hands at normal ambient pressure, after donning a non-elastic glove with a pressure differential of 0.29 atm, and after donning an elastic glove with a pressure differential of 0.29 and 0.65 atm. Range of motion (ROM) of the index finger and surface electromyography (EMG) amplitudes during finger flexion were measured. ROM with gloves was significantly smaller than that of bare hands, but was similar between conditions of gloves regardless of elasticity and pressure differentials. However, EMG amplitudes with the elastic glove of 0.29 and 0.65 atm were significantly smaller than those with the non-elastic glove of 0.29 atm. The results suggest that mobility of the elastic glove of 0.65 atm may be better than that of the non-elastic glove of 0.29 atm, similar to that used in the current EVA suit.
NASA Technical Reports Server (NTRS)
Ross, Amy
2008-01-01
This presentation addressed the question "What is a spacesuit glove?" - a highly specialized mobility system. It is an excellent basic tutorial on the design considerations of a spacesuit glove and the many facets of developing a glove that provides good mobility and thermal protection.
Micropunctures of rubber gloves used in oral surgery.
Skaug, N
1976-10-01
In 720 operations in ambulatory oral surgery, the 2,880 surgical rubber gloves used were tested at the end of operation for perforations not earlier detected (microperforations). Gloves of ordinary thickness (type A) and of a thicker quality (type B) were examined. Perforations were found in 1495% and 22.0% of type A gloves and in 3.2% and 2.0% of type B gloves when oral surgeons and dental students, respectively, were operators. Gloves worn by operation assistants showed a lower incidence of perforation. Before operation, 50 gloves of type A were punctured at the tip of right index finger by a sterile dental probe. Results of bacteriologic examinations of the right index and middle fingers strongly indicated that a high number of bacteria passed through pinholes in the gloves. The intact surgical glove represents an impermeable barrier, protecting not only the operation wound against skin bacteria from the hands of the oral surgeon, but also the oral surgeon against pathogenic microorganisms, in particular hepatitis virus type B, escaping from the oral cavity of the patient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forbes, Elizabeth H.
2015-08-01
On 6/26/2015 at approximately 1445 in 894/136, a pulse thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following an electrical performance test that is routinely conducted on thermal batteries. A dedicated tester for this operation was used and it ran the test until the nominal 28-volt output of the battery had dropped to 5 volts, usually indicative of the battery being spent and safe enough to move. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another primary containment box within the same room;more » initial indications are that the battery experienced an over-pressurization failure which led to the battery's base plate being expelled and the operator receiving a non-recordable injury (bruising to the palm of the hand) from the pressure of the expulsion. The operator was wearing the prescribed PPE (safety glasses and high temperature glove) and was handling the battery appropriately with an open, flat hand. Pictures of the scene are below.« less
Tactile Gloves for Autonomous Grasping With the NASA/DARPA Robonaut
NASA Technical Reports Server (NTRS)
Martin, T. B.; Ambrose, R. O.; Diftler, M. A.; Platt, R., Jr.; Butzer, M. J.
2004-01-01
Tactile data from rugged gloves are providing the foundation for developing autonomous grasping skills for the NASA/DARPA Robonaut, a dexterous humanoid robot. These custom gloves compliment the human like dexterity available in the Robonaut hands. Multiple versions of the gloves are discussed, showing a progression in using advanced materials and construction techniques to enhance sensitivity and overall sensor coverage. The force data provided by the gloves can be used to improve dexterous, tool and power grasping primitives. Experiments with the latest gloves focus on the use of tools, specifically a power drill used to approximate an astronaut's torque tool.
Pontén, Ann; Hamnerius, Nils; Bruze, Magnus; Hansson, Christer; Persson, Christina; Svedman, Cecilia; Thörneby Andersson, Kirsten; Bergendorff, Ola
2013-02-01
An increased frequency of occupational contact hand dermatitis among surgical operating theatre personnel has been noticed. To evaluate patients with occupational contact dermatitis caused by their rubber gloves, and to describe a method for analysing the content of the allergens in the gloves. Patch tests were performed with the baseline series, a rubber chemical series, and the patients' own gloves. A method for analysing 1,3-diphenylguanidine (DPG) and cetylpyridinium chloride in the gloves was developed. Contact allergy to thiuram mix was found in 8 of 16 patients, whereas 12 of 16 patients reacted to DPG. In 7 of 8 patients, contact allergy to cetylpyridinium chloride was found. In the patients' gloves, cetylpyridinium chloride and DPG were detected at higher concentrations on the inside of the gloves than on the outside. Most patients had worked for decades in their present occupations, but their hand dermatitis had only been present for months. Contact allergy to DPG in gloves has been disputed, but, in this study, we were able to confirm the presence of DPG and cetylpyridinium chloride in the causative gloves by using a modified method for the analysis. The presence of these chemicals in gloves caused an increase in occupational contact dermatitis in surgical operating theatre personnel. © 2012 John Wiley & Sons A/S.
Li, Huan; Sinha, Tridib K; Oh, Jeong Seok; Kim, Jin Kuk
2018-04-25
Inspired by the epidermis-dermis composition of human skin, here we have simply developed a lightweight, robust, flexible, and biocompatible single-electrode triboelectric nanogenerator (S-TENG)-based prototype of bilayer artificial skin, by attaching one induction electrode with unfoamed skin layer of microcellular thermoplastic polyurethane (TPU) foam, which shows high-performance object manipulation [by responding differently toward different objects, viz., aluminum foil, balloon, cotton glove, human finger, glass, rubber glove, artificial leather, polyimide, poly(tetrafluoroethylene) (PTFE), paper, and wood], due to electrification and electrostatic induction during contact with the objects having different chemical functionalities. Comparative foaming behavior of ecofriendly supercritical fluids, viz., CO 2 over N 2 under variable temperatures (e.g., 130 and 150 °C) and constant pressure (15 MPa), have been examined here to pursue the soft and flexible triboelectric TPU foam. The foam derived by CO 2 foaming at 150 °C has been prioritized for development of S-TENG. Foam derived by CO 2 foaming at 130 °C did not respond as well due to the smaller cell size, higher hardness, and thicker skin. Inflexible N 2 -derived foam was not considered for S-TENG fabrication. Object manipulation performance has been visualized by principal component analysis (PCA), which shows good discrimination among responses to different objects.
Mechanically Compliant Electronic Materials for Wearable Photovoltaics and Human-Machine Interfaces
NASA Astrophysics Data System (ADS)
O'Connor, Timothy Francis, III
Applications of stretchable electronic materials for human-machine interfaces are described herein. Intrinsically stretchable organic conjugated polymers and stretchable electronic composites were used to develop stretchable organic photovoltaics (OPVs), mechanically robust wearable OPVs, and human-machine interfaces for gesture recognition, American Sign Language Translation, haptic control of robots, and touch emulation for virtual reality, augmented reality, and the transmission of touch. The stretchable and wearable OPVs comprise active layers of poly-3-alkylthiophene:phenyl-C61-butyric acid methyl ester (P3AT:PCBM) and transparent conductive electrodes of poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) and devices could only be fabricated through a deep understanding of the connection between molecular structure and the co-engineering of electronic performance with mechanical resilience. The talk concludes with the use of composite piezoresistive sensors two smart glove prototypes. The first integrates stretchable strain sensors comprising a carbon-elastomer composite, a wearable microcontroller, low energy Bluetooth, and a 6-axis accelerometer/gyroscope to construct a fully functional gesture recognition glove capable of wirelessly translating American Sign Language to text on a cell phone screen. The second creates a system for the haptic control of a 3D printed robot arm, as well as the transmission of touch and temperature information.
Edlich, Richard F; Long, William B; Gubler, K Dean; Rodeheaver, George T; Thacker, John G; Borel, Lise; Chase, Margot E; Cross, Catherine L; Fisher, Allyson L; Lin, Kant Y; Cox, Mary J; Zura, Robert B
2009-02-01
During the last 25 years, scientific experimental and clinical studies have documented the dangers of cornstarch powder on examination and surgical gloves because the cornstarch promotes wound infection, causes serious peritoneal adhesions and granulomatous peritonitis, and is a well-documented vector of the latex allergy epidemic in the world. Realizing the dangers of cornstarch on examination and surgical gloves, Germany's regulations of personal protective equipment banned the use of surgical glove powder cornstarch in 1997. In 2000, the Purchasing and Supply agency for the United Kingdom ceased to purchase any gloves lubricated with cornstarch. Realizing the dangers of cornstarch-powdered gloves, many hospitals and clinics in the United States have banned the use of cornstarch-powdered examination and surgical gloves. Hospitals that have banned cornstarch in their examination and surgical gloves have noted a marked reduction in the latex allergy epidemic in their facilities. Realizing the dangers of cornstarch-powdered examination and surgical gloves, Dr Sheila A. Murphey, branch chief, Infection Control Devices Branch, Division of Anesthesiology, General Hospital, Infection Control, and Dental Devices Office of Device Evaluation, Center for Devices and Radiological Health of the Food and Drug Administration (FDA), recommended that a Citizen's Petition be filed to the FDA to ban cornstarch on surgical and examination gloves. The 12 authors of this report have attached the enclosed petition to the FDA to ban the use of cornstarch on all synthetic and latex examination and surgical gloves used in the United States.
Oreskov, Katia W; Søsted, Heidi; Johansen, Jeanne D
2015-06-01
Hand eczema is frequent among Danish hairdressers, and they are advised to use gloves as protection. However, studies indicate that a significant proportion use gloves inappropriately. To determine whether hairdressers and apprentices use protective gloves in the correct way, and to determine whether a demonstration of correct use could cause an improvement. Forty-three hairdressers and apprentices were asked to perform a hair wash while wearing gloves. The shampoo used was contaminated with an ultraviolet (UV) trace material. Two rounds of hair washing were carried out by each person, interrupted by a demonstration of how to use gloves correctly. Photographs were taken to compare UV contamination before and after the demonstration. All of the participants (100%) had their hands contaminated during the first round; the area ranged between 0.02 and 101.37 cm(2) (median 3.62 cm(2)). In the second round, 55.8% were contaminated (range 0.00-3.08 cm(2) ; median 0.01 cm(2)). The reduction in contaminated skin areas was statistically significant (p < 0.001), proving an effect of the glove demonstration. There were no significant differences between hairdressers and apprentices. Hairdressers and apprentices lack knowledge on how to handle gloves correctly. A short demonstration of correct glove use made a significant difference in the skin protection provided by gloves. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Yoo, Won-Gyu
2015-01-01
[Purpose] The present study examined the effects of wearing rubber gloves on the activities of the forearm and shoulder muscles during two dishwashing stages. [Subjects] This study included 10 young females. [Methods] The participants performed two dishwashing stages (washing and rinsing) with and without rubber gloves. The activities of the wrist flexor and upper trapezius muscles were measured using wireless electromyography. [Results] During the washing stage, the activities of the wrist flexor and upper trapezius muscles were significantly greater without gloves than with gloves when performing the same tasks. However, during the rinsing stage, the activities of these muscles did not differ significantly according to the use of gloves. [Conclusion] Dishwashers should wear gloves during the washing stage to prevent wrist and shoulder pain. PMID:26311980
2017-01-01
Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro–Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves. PMID:29207573
An evaluation of hospital hand hygiene practice and glove use in Hong Kong.
Chau, Janita P-C; Thompson, David R; Twinn, Sheila; Lee, Diana T F; Pang, Sharon W M
2011-05-01
To identify omissions in hand hygiene practice and glove use among hospital workers in Hong Kong. Hospital-acquired infection is the commonest complication affecting hospitalised patients. Even though research evidence suggests that hand hygiene and proper glove use are the most important ways to prevent the spread of disease and infection, compliance with both are reported to be unacceptably low. An observational study of hospital workers in one acute and two convalescence and rehabilitation hospitals in Hong Kong was conducted. The participating clinical areas included the medical and surgical wards, accident and emergency department and intensive care unit. Hand hygiene practice and glove use amongst 206 hospital health and support workers, stratified according to years of working experience, were observed. The number of observed episodes for hand hygiene was 1037 and for glove use 304. Compliance with hand hygiene was 74.7% and with glove use 72.4%. In approximately two-third of episodes, participants washed their hands after each patient contact; though, 78.5% failed to rub their hands together vigorously for at least 15 seconds. The major break in compliance with glove use was failure to change gloves between procedures on the same patient. In 28.6% of observed glove use episodes, participants did not wear gloves during procedures that exposed them to blood, body fluids, excretion, non-intact skin or mucous membranes. Significant differences in performance scores on antiseptic hand rub were found between the two types of hospital and on glove use between the three groups of work experience: ≤ 5, 6-10, >10 years. Education and reinforcement of proper hand hygiene practice and glove use among hospital health and support workers is needed. © 2011 Blackwell Publishing Ltd.
Disinfection of gloves: feasible, but pay attention to the disinfectant/glove combination.
Scheithauer, S; Häfner, H; Seef, R; Seef, S; Hilgers, R D; Lemmen, S
2016-11-01
Compliance with hand hygiene is complicated by indications for hand disinfection in rapid succession during the care of one patient. In such situations, disinfection of gloves could facilitate better workflow and optimize compliance rates. We analysed the efficacy of disinfecting gloves by comparing an individual effect of five different hand disinfectant solutions in combination with three different glove types. The investigation was performed in accordance with DIN EN 1500:2013. For all combinations, ten analyses were performed, including (1) right/left-hand examination disinfection efficacy after the first and fifth contamination with E. coli K12 NCTC 10538, (2) recovery rates after contamination, (3) reduction efficacy, (4) fingertip immersion culture, and (5) check for tightness. Disinfection of the ungloved hands was taken as an additional benchmark. The disinfection efficacy for all disinfectant/glove combinations was better with rather than without gloves. For eight combinations, the disinfection efficacy was always >5.0 log 10 . There were significant differences within the gloves (P=0.0021) and within the disinfectant product (P=0.0023), respectively. In detail, Nitril Blue Eco-Plus performed significantly better than Vasco Braun (P=0.0017) and Latex Med Comfort (P=0.0493). Descoderm showed a significantly worse performance than Promanum pure (P=0.043). In the check for tightness, only the Vasco Braun gloves showed no leaks in all samples. There were relevant qualitative differences pertaining to the comfort of disinfecting gloves. The disinfection efficacy for the different disinfectant/glove combinations was greater than for the ungloved hands. However, various disinfectant/glove combinations produce relevant differences as regards disinfection efficacy. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
The use of powdered gloves in dental practice: a cause for concern?
Field, E A
1997-01-01
To critically review the potential hazards associated with the use of powdered, natural rubber latex (NRL) gloves in dental practice and to report some practical difficulties which may be encountered when handling dental materials with powdered NRL gloves. Articles published in the international literature over the last 10 years. A number of recent studies in the medical and surgical literature have confirmed that NRL proteins leach out of latex gloves and bind to surgical glove powders. The most serious, potential hazard associated with the continued use of powdered NRL gloves in dental practice is that of latex sensitization by exposure to aerosolized NRL proteins. Hand dermatitis is now recognized as an occupational hazard in dentistry and has been associated with the continuous wearing of protective gloves. Studies, in the dermatological literature, have suggested that glove powders may exacerbate an irritant dermatitis and enhance the potential for adverse reactions to other components of NRL gloves. The surgical literature has already highlighted the risks of post-operative granuloma formation, due to glove powder contamination of the surgical wound. The possible effects of powder contamination of dental implant sites, on the outcome and success of implants has yet to be established. Recent in vitro studies have investigated the effect of latex glove contamination on the shear-bond strength of porcelain laminate veneers: one study demonstrated that starch powder significantly affected the bond strength, whereas the other showed that latex glove contamination of the porcelain surface did not have any significant effect. Long-term, in vivo studies are now required. Dental practitioners should consider the potential health risks which are associated with the use of powdered NRL in dental practice. Powder contamination may affect the long-term results and success of clinical procedures in dentistry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maienschein, J.L.; Garcia, F.; Garza, R.G.
Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculationalmore » method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less
Ahn, Sejin; Son, Tae Hwa; Cho, Ara; Gwak, Jihye; Yun, Jae Ho; Shin, Keeshik; Ahn, Seoung Kyu; Park, Sang Hyun; Yoon, Kyunghoon
2012-09-01
A simple direct solution coating process for forming CuInSe₂ (CIS) thin films was described, employing a low-cost and environmentally friendly precursor solution. The precursor solution was prepared by mixing metal acetates, ethanol, and ethanolamine. The facile formation of a precursor solution without the need to prefabricate nanoparticles enables a rapid and easy processing, and the high stability of the solution in air further ensures the precursor preparation and the film deposition in ambient conditions without a glove box. The thin film solar cell fabricated with the absorber film prepared by this route showed an initial conversion efficiency of as high as 7.72 %. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
O’Brien, J. Patrick; Malvankar, Nikhil S.
2017-01-01
Anaerobic microorganisms play a central role in several environmental processes and regulate global biogeochemical cycling of nutrients and minerals. Many anaerobic microorganisms are important for the production of bioenergy and biofuels. However, the major hurdle in studying anaerobic microorganisms in the laboratory is the requirement for sophisticated and expensive gassing stations and glove boxes to create and maintain the anaerobic environment. This appendix presents a simple design for a gassing station that can be used readily by an inexperienced investigator for cultivation of anaerobic microorganisms. In addition, this appendix also details the low-cost assembly of bioelectrochemical systems and outlines a simplified procedure for cultivating and analyzing bacterial cell cultures and biofilms that produce electric current, using Geobacter sulfurreducens as a model organism. PMID:27858972
Development of a versatile laser light scattering instrument
NASA Astrophysics Data System (ADS)
Meyer, William V.; Ansari, Rafat R.
1990-10-01
A versatile laser light scattering (LLS) instrument is developed for use in microgravity to measure microscopic particles of 30 A to above 3 microns. Since it is an optical technique, LLS does not affect the sample being studied. A LLS instrument built from modules allows several configurations, each optimized for a particular experiment. The multiangle LLS instrument can be mounted in the rack in the Space Shuttle and on Space Station Freedom. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations. This offers simple means of flying a great number of experiments without the additional requirements of full-scale flight hardware experiments.
STS-107 Crew Equipment Interface Test (CEIT)activities at SPACEHAB
NASA Technical Reports Server (NTRS)
2001-01-01
KENNEDY SPACE CENTER, Fla. -- During Crew Equipment Interface Test activities at SPACEHAB, Cape Canaveral, Fla., STS-107 Mission Specialist Kalpana Chawla trains on a glove box experiment. As a research mission, STS-107 will carry the SPACEHAB Double Module in its first research flight into space and a broad collection of experiments ranging from material science to life science. CEIT activities enable the crew to perform certain flight operations, operate experiments in a flight-like environment, evaluate stowage locations and obtain additional exposure to specific experiment operations. Other STS-107 crew members are Commander Rick Douglas Husband; Pilot William C. McCool; Payload Commander Michael P. Anderson; Mission Specialists Laurel Blair Salton Clark and David M. Brown; and Payload Specialist Ilan Ramon, of Israel. STS-107 is scheduled for launch May 23, 2002
Recent progress on gas tungsten arc welding of vanadium alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, J.F.; Grossbeck, M.L.; Goodwin, G.M.
1997-04-01
This is a progress report on a continuing research project to acquire a fundamental understanding of the metallurgical processes in the welding of vanadium alloys. It also has the goal of developing techniques for welding structural vanadium alloys. The alloy V-4Cr-4Ti is used as a representative alloy of the group; it is also the prime candidate vanadium alloy for the U.S. Fusion Program at the present time. However, other alloys of this class were used in the research as necessary. The present work focuses on recent findings of hydrogen embrittlement found in vanadium alloy welds. It was concluded that themore » atmosphere in the inert gas glove box was insufficient for welding 6mm thick vanadium alloy plates.« less
Development of a versatile laser light scattering instrument
NASA Technical Reports Server (NTRS)
Meyer, William V.; Ansari, Rafat R.
1990-01-01
A versatile laser light scattering (LLS) instrument is developed for use in microgravity to measure microscopic particles of 30 A to above 3 microns. Since it is an optical technique, LLS does not affect the sample being studied. A LLS instrument built from modules allows several configurations, each optimized for a particular experiment. The multiangle LLS instrument can be mounted in the rack in the Space Shuttle and on Space Station Freedom. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations. This offers simple means of flying a great number of experiments without the additional requirements of full-scale flight hardware experiments.
Laser light scattering instrument advanced technology development
NASA Technical Reports Server (NTRS)
Wallace, J. F.
1993-01-01
The objective of this advanced technology development (ATD) project has been to provide sturdy, miniaturized laser light scattering (LLS) instrumentation for use in microgravity experiments. To do this, we assessed user requirements, explored the capabilities of existing and prospective laser light scattering hardware, and both coordinated and participated in the hardware and software advances needed for a flight hardware instrument. We have successfully breadboarded and evaluated an engineering version of a single-angle glove-box instrument which uses solid state detectors and lasers, along with fiber optics, for beam delivery and detection. Additionally, we have provided the specifications and written verification procedures necessary for procuring a miniature multi-angle LLS instrument which will be used by the flight hardware project which resulted from this work and from this project's interaction with the laser light scattering community.
Iskandar, S M; Elias, S; Jumiah, H; Asri, M T M; Masrianis, A; Ab Rahman, M Z; Taiman, K; Abdul Rashid, M Y
2004-05-01
The radiation-response characteristics of polymetharylic acid gel dosimeter prepared with different concentrations of monomer and cross-linker is described in these studies. The dosimeters were prepared under the hypoxic condition in a glove box and were then irradiated with gamma-rays produced by Co-60 radionuclide that was generated at 1.25MeV energy. The irradiation took place at different doses ranged from 0Gy to 19Gy. Due to the radiation activities, chain-reaction polymerisation processes had taken place in the formation of polymethacrylic acid (PMAA) gel, which cause the dose response mechanism increased in the NMR relaxation rates of protons. It has been observed that for higher concentration of monomer and cross-linker, the polymerization rate was increased.
Fundamentals of Polymer Gel Dosimeters
NASA Astrophysics Data System (ADS)
McAuley, Kim B.
2006-12-01
The recent literature on polymer gel dosimetry contains application papers and basic experimental studies involving polymethacrylic-acid-based and polyacrylamide-based gel dosimeters. The basic studies assess the relative merits of these two most commonly used dosimeters, and explore the effects of tetrakis hydroxymethyl phosphonium chloride (THPC) antioxidant on dosimeter performance. Polymer gel dosimeters that contain THPC or other oxygen scavengers are called normoxic dosimeters, because they can be prepared under normal atmospheric conditions, rather than in a glove box that excludes oxygen. In this review, an effort is made to explain some of the underlying chemical phenomena that affect dosimeter performance using THPC, and that lead to differences in behaviour between dosimeters made using the two types of monomer systems. Progress on the development of new more effective and less toxic dosimeters is also reported.
Mosely, Jackie A; Stokes, Peter; Parker, David; Dyer, Philip W; Messinis, Antonis M
2018-02-01
A novel method has been developed that enables chemical compounds to be transferred from an inert atmosphere glove box and into the atmospheric pressure ion source of a mass spectrometer whilst retaining a controlled chemical environment. This innovative method is simple and cheap to implement on some commercially available mass spectrometers. We have termed this approach inert atmospheric pressure solids analysis probe ( iASAP) and demonstrate the benefit of this methodology for two air-/moisture-sensitive chemical compounds whose characterisation by mass spectrometry is now possible and easily achieved. The simplicity of the design means that moving between iASAP and standard ASAP is straightforward and quick, providing a highly flexible platform with rapid sample turnaround.
Permeation of fingerprints through laboratory gloves.
Willinski, G
1980-07-01
Repeated controlled tests have shown that impressions from laboratory gloves will print onto optical components in 20 to 40 min and, in some cases, sooner. Careful testing demonstrated that palmar sweat passed through the glove material; the problem was not that gloves conform to the friction ridges of the fingers and then transfer some contaminant. The problem can be alleviated to a great extent by wearing thin cotton gloves like those commonly used in the film industry.
Lierman, Sylvie; De Sutter, Petra; Dhont, Marc; Van der Elst, Josiane
2007-10-01
To submit different glove brands to double-quality control tests using mouse embryo assay (MEA) and the human sperm motility assay (HuSMA). Operator protection against infectious body fluid contamination is a safety issue in assisted reproductive technology (ART). When using gloves in the ART laboratory, toxic substances can be transmitted to culture media, even during brief contact. Quality control study of gloves in ART. University hospital-based infertility center. Seven- to 8-week-old female B6D2F1 hybrid mice. We tested two surgical, two cleanroom, and six examination glove brands. Only gloves brands that passed both HuSMA and MEA were submitted to further QC using zona-free and/or cryopreserved MEA. Sperm motility index, two-cell and blastocyst development, blastocyst total cell number. Quality control by MEA and HuSMA identified two glove brands to be nontoxic. Our study shows that gloves used in ART can be toxic and should be tested as part of an ongoing quality control program.
Glove perforation time and frequency in total hip arthroplasty procedures.
Kaya, Ibrahim; Uğraş, Akin; Sungur, Ibrahim; Yilmaz, Murat; Korkmaz, Musa; Cetinus, Ercan
2012-01-01
The aim of the present study was to investigate glove perforation rate and time and evaluate the factors affecting glove perforation in total hip arthroplasty (THA). Nine hundred seventy-nine gloves used in 57 THA procedures were assessed according to the perforation. Forty-four (77.2%) procedures were primary THA and 13 (22.8%) were revision THA. Gloves were changed when perforated, become dirty with blood or blood products, and before bone cementing. All gloves were filled with water at the end of the operation and controlled for perforation. Two hundred and one surgical gloves used during scrubbing and removed after draping the patient were examined as the control group. The location (which finger), number and time of the perforation, surgery type and duration, and distribution of the perforation location according to the surgical team were assessed. Patients' mean age was 62.9 ± 14.6 (range: 33 to 97) years and the mean surgery duration was 162.9 ± 32.0 minutes. Thirty-two glove perforations were noted in 19 of the operations. Of these perforations, 28 belonged to the surgeons and first assistants. There was no significant difference between the dominant or non-dominant hand according to the location of perforations. Perforations in the first and second fingers of the gloves accounted for 81.3% of all perforations. There was no significant difference in terms of number of gloves used, perforation numbers and operation duration between the primary and revision THA procedures. Two perforated gloves (0.99%) were found in the control group and the difference between the number of perforations in the control and study groups was significant (p=0.048). We recommend the use of two pairs of gloves to avoid the risk of contamination and protect the surgical team from infectious disease in major surgeries like THA. Surgical gloves should be changed when they are excessively contaminated with surgical fluids and the surgeon and first assistant should also change their outer gloves at an average of every 90 minutes.
Reduction of antigenic protein levels in latex gloves after gamma irradiation.
Zehr, B D; Gromelski, S; Beezhold, D
1994-01-01
Gamma irradiation is currently the method most commonly used to sterilize surgical gloves. In this study, the effect of gamma irradiation on antigenic proteins in latex gloves was examined. Protein extraction and quantitation were carried out using latex gloves before and after sterilization. Antigenic protein levels were determined by an ELISA assay specific for latex proteins (LEAP). LEAP analysis revealed a significant decrease after gamma-irradiation sterilization. This observation may partially explain the lower levels of extractable antigenic proteins found in sterile surgical gloves compared with nonsterile examination gloves. However, gamma irradiation was less effective than autoclave sterilization in reducing protein levels.
Thermal Analysis of a Metallic Wing Glove for a Mach-8 Boundary-Layer Experiment
NASA Technical Reports Server (NTRS)
Gong, Leslie; Richards, W. Lance
1998-01-01
A metallic 'glove' structure has been built and attached to the wing of the Pegasus(trademark) space booster. An experiment on the upper surface of the glove has been designed to help validate boundary-layer stability codes in a free-flight environment. Three-dimensional thermal analyses have been performed to ensure that the glove structure design would be within allowable temperature limits in the experiment test section of the upper skin of the glove. Temperature results obtained from the design-case analysis show a peak temperature at the leading edge of 490 F. For the upper surface of the glove, approximately 3 in. back from the leading edge, temperature calculations indicate transition occurs at approximately 45 sec into the flight profile. A worst-case heating analysis has also been performed to ensure that the glove structure would not have any detrimental effects on the primary objective of the Pegasus a launch. A peak temperature of 805 F has been calculated on the leading edge of the glove structure. The temperatures predicted from the design case are well within the temperature limits of the glove structure, and the worst-case heating analysis temperature results are acceptable for the mission objectives.
The Influence of Glove Type on Simulated Wheelchair Racing Propulsion: A Pilot Study.
Rice, I; Dysterheft, J; Bleakney, A W; Cooper, R A
2016-01-01
Our purpose was to examine the influence of glove type on kinetic and spatiotemporal parameters at the handrim in elite wheelchair racers. Elite wheelchair racers (n=9) propelled on a dynamometer in their own racing chairs with a force and moment sensing wheel attached. Racers propelled at 3 steady state speeds (5.36, 6.26 & 7.60 m/s) and performed one maximal effort sprint with 2 different glove types (soft & solid). Peak resultant force, peak torque, impulse, contact angle, braking torque, push time, velocity, and stroke frequency were recorded for steady state and sprint conditions. Multiple nonparametric Wilcoxon matched pair's tests were used to detect differences between glove types, while effect sizes were calculated based on Cohen's d. During steady state trials, racers propelled faster, using more strokes and larger contact angle, while applying less impulse with solid gloves compared to soft gloves. During the sprint condition, racers achieved greater top end velocities, applying larger peak force, with less braking torque with solid gloves compared to soft gloves. Use of solid gloves may provide some performance benefits to wheelchair racers during steady state and top end velocity conditions. © Georg Thieme Verlag KG Stuttgart · New York.
The Efficacy of Anti-vibration Gloves
Hewitt, Sue; Dong, Ren; McDowell, Tom; Welcome, Daniel
2016-01-01
Anyone seeking to control the risks from vibration transmitted to the hands and arms may contemplate the use of anti-vibration gloves. To make an informed decision about any type of personal protective equipment, it is necessary to have performance data that allow the degree of protection to be estimated. The information provided with an anti-vibration glove may not be easy to understand without some background knowledge of how gloves are tested and does not provide any clear route for estimating likely protection. Some of the factors that influence the potential efficacy of an anti-vibration glove include how risks from hand–arm vibration exposure are assessed, how the standard test for a glove is carried out, the frequency range and direction of the vibration for which protection is sought, how much hand contact force or pressure is applied and the physical limitations due to glove material and construction. This paper reviews some of the background issues that are useful for potential purchasers of anti-vibration gloves. Ultimately, anti-vibration gloves cannot be relied on to provide sufficient and consistent protection to the wearer and before their use is contemplated all other available means of vibration control ought first to be implemented. PMID:27582615
Reduction of use of latex gloves in food handlers: an intervention study.
Lee, A; Nixon, R; Frowen, K
2001-02-01
Frequent latex glove use is a risk factor for the development of latex allergy. With the increase in latex glove use, latex allergy has become more prevalent. There are a number of occupational groups in which the use of latex gloves is both inappropriate and even hazardous, including food handlers, where the hazard relates particularly to their latex-sensitive customers. The aim of this study was to assess both the use of latex gloves by food handlers and the impact of an intervention study on reducing latex glove use. This was done at the Queen Victoria Market in Melbourne, Australia. We found that 10 out of 30 stalls (33%) used latex gloves, and that following a short education program, this was reduced to 1 stall (3%, p=0.006). The potential to reduce latex glove use by using this intervention study was 93% (95% confidence interval of 54%-100%). We recommend that food handlers be educated during their training, not only about hygiene issues, but also about the appropriate type of glove to wear, in order to prevent both the development of a new occupational group at risk of becoming allergic to latex, but more importantly to protect their latex-sensitive customers.
Finite-Element Analysis of a Mach-8 Flight Test Article Using Nonlinear Contact Elements
NASA Technical Reports Server (NTRS)
Richards, W. Lance
1997-01-01
A flight test article, called a glove, is required for a Mach-8 boundary-layer experiment to be conducted on a flight mission of the air-launched Pegasus(reg) space booster. The glove is required to provide a smooth, three-dimensional, structurally stable, aerodynamic surface and includes instrumentation to determine when and where boundary-layer transition occurs during the hypersonic flight trajectory. A restraint mechanism has been invented to attach the glove to the wing of the space booster. The restraint mechanism securely attaches the glove to the wing in directions normal to the wing/glove interface surface, but allows the glove to thermally expand and contract to alleviate stresses in directions parallel to the interface surface. A finite-element analysis has been performed using nonlinear contact elements to model the complex behavior of the sliding restraint mechanism. This paper provides an overview of the glove design and presents details of the analysis that were essential to demonstrate the flight worthiness of the wing-glove test article. Results show that all glove components are well within the allowable stress and deformation requirements to satisfy the objectives of the flight research experiment.
Phillips, A. M.; Birch, N. C.; Ribbans, W. J.
1997-01-01
Twenty-five orthopaedic surgeons underwent eight motor and sensory tests while using four different glove combinations and without gloves. As well as single and double latex, surgeons wore a simple Kevlar glove with latex inside and outside and then wore a Kevlar and Medak glove with latex inside and outside, as recommended by the manufacturers. The effect of learning with each sequence was neutralised by randomising the glove order. The time taken to complete each test was recorded and, where appropriate, error rates were noted. Simple sensory tests took progressively longer to perform so that using the thickest glove combination led to the completion times being doubled. Error rates increased significantly. Tests of stereognosis also took longer and use of the thickest glove combination caused these tests to take three times as long on average. Error rates again increased significantly. However, prolongation of motor tasks was less marked. We conclude that, armed with this quantitative analysis of sensitivity and dexterity impairment, surgeons can judge the relative difficulties that may be incurred as a result of wearing the gloves against the benefits that they offer in protection. PMID:9135240
Glove Perforations During Interventional Radiological Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leena, R. V., E-mail: leenarv_76@yahoo.co.uk; Shyamkumar, N. K.
2010-04-15
Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.
1982-02-08
S82-26645 (March 1982) --- Spacesuit inner gloves consist of pressure bladders covered by Beta Cloth. EVA outer gloves are made of Beta Cloth, Mylar and a metallic mesh hand area. The thumb and fingertips of the glove are molded of silicone rubber to permit a degree of sensitivity. The inner gloves attach to the suit by pressure sealing rings, similar to these used in helmet-to-suit connections. The outer gloves served as a cover to protect from micrometeorites, abrasions and heat.
Initial Work Toward a Robotically Assisted EVA Glove
NASA Technical Reports Server (NTRS)
Rogers, J.; Peters, B.; McBryan, E.; Laske, E.
2016-01-01
The Space Suit RoboGlove is a device designed to provide additional grasp strength or endurance for an EVA crew member since gloved hand performance is a fraction of what the unencumbered human hand can achieve. There have been past efforts to approach this problem by employing novel materials and construction techniques to the glove design, as well as integrating powered assistance devices. This application of the NASA/GM RoboGlove technology uses a unique approach to integrate the robotic actuators and sensors into a Phase VI EVA glove. This design provides grasp augmentation to the glove user while active, but can also function as a normal glove when disabled. Care was taken to avoid adding excessive bulk to the glove or affecting tactility by choosing low-profile sensors and extrinsically locating the actuators. Conduits are used to guide robotic tendons from linear actuators, across the wrist, and to the fingers. The second generation of the SSRG includes updated electronics, sensors, and actuators to improve performance. The following discusses the electromechanical design, softgoods integration, and control system of the SSRG. It also presents test results from the first integration of a powered mobility element onto a space suit, the NASA Mark III. Early results show that sensor integration did not impact tactile feedback in the glove and the actuators show potential for reduction in grasp fatigue over time.
Robinson, Andrew L; Lee, Hyun Jung; Kwon, Junehee; Todd, Ewen; Rodriguez, Fernando Perez; Ryu, Dojin
2016-02-01
Hand washing and glove use are the main methods for reducing bacterial cross-contamination from hands to ready-to-eat food in a food service setting. However, bacterial transfer from hands to gloves is poorly understood, as is the effect of different durations of soap rubbing on bacterial reduction. To assess bacterial transfer from hands to gloves and to compare bacterial transfer rates to food after different soap washing times and glove use, participants' hands were artificially contaminated with Enterobacter aerogenes B199A at ∼9 log CFU. Different soap rubbing times (0, 3, and 20 s), glove use, and tomato dicing activities followed. The bacterial counts in diced tomatoes and on participants' hands and gloves were then analyzed. Different soap rubbing times did not significantly change the amount of bacteria recovered from participants' hands. Dicing tomatoes with bare hands after 20 s of soap rubbing transferred significantly less bacteria (P < 0.01) to tomatoes than did dicing with bare hands after 0 s of soap rubbing. Wearing gloves while dicing greatly reduced the incidence of contaminated tomato samples compared with dicing with bare hands. Increasing soap washing time decreased the incidence of bacteria recovered from outside glove surfaces (P < 0.05). These results highlight that both glove use and adequate hand washing are necessary to reduce bacterial cross-contamination in food service environments.
Understanding Factors that Influence Protective Glove Use among Automotive Spray Painters
Ceballos, Diana; Reeb-Whitaker, Carolyn; Glazer, Patricia; Murphy-Robinson, Helen; Yost, Michael
2017-01-01
Dermal contact with isocyanate-based coatings may lead to systemic respiratory sensitization. The most common isocyanates found in sprayed automotive coatings are monomeric and oligomeric 1,6-hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI). Most spray painters use thin (4–5 mil) latex gloves that are not effective at preventing dermal exposures when spraying isocyanate paints. Personal interviews with collision repair industry personnel and focus groups with spray painters were held to characterize risk awareness, to examine perceptions and challenges concerning protective glove use and selection, and to generate ideas for protective glove use interventions. The most popular gloves among spray painters were thin (4–5 mil) and thick (14 mil) latex. We found that medium to thick (6–8 mil) nitrile were not always perceived as comfortable and were expected to be more expensive than thin (4–5 mil) latex gloves. Of concern is the users’ difficulty to distinguish between nitrile and latex gloves; latex gloves are now sold in different colors including blue, which has traditionally been associated with nitrile gloves. Even though spray painters were familiar with the health hazards related to working with isocyanate paints; most were not always aware that dermal exposure to isocyanates could contribute to the development of occupational asthma. There is a need for more research to identify dermal materials that are protective against sprayed automotive coatings. Automotive spray painters and their employers need to be educated in the selection and use of protective gloves, specifically on attributes such as glove material, color, and thickness. PMID:24215135
Development of a Facility Management and Improvement Manual for Army Service Schools.
1983-03-01
Ehhhhomhmhhhhlo EEEEEEEohhhhhI L-Ii Ilk . ~MICROCOPY RESOLUTION TEST CHART NATIONAL BURESU Of STA OSN-T63-A NA01BRA FSADRS16- construction m*nilhlli 8mbtg 10b...U.S. Army Construction Engineering Research Lab. P.O. Box 4005 • 4A762731AT41-A-001 Champaign, IL 61820 _ It. CONTROLLING OFFICtNAME AND ADDRESS 37...developing a data collection and analysis method. The prototype method was discussed in CERL Interim Report P-ill. 3 This prototype method was tested by
Klingner, Thomas D; Boeniger, Mark F
2002-05-01
Wearing chemical-resistant gloves and clothing is the primary method used to prevent skin exposure to toxic chemicals in the workplace. The process for selecting gloves is usually based on manufacturers' laboratory-generated chemical permeation data. However, such data may not reflect conditions in the workplace where many variables are encountered (e.g., elevated temperature, flexing, pressure, and product variation between suppliers). Thus, the reliance on this selection process is questionable. Variables that may influence the performance of chemical-resistant gloves are identified and discussed. Passive dermal monitoring is recommended to evaluate glove performance under actual-use conditions and can bridge the gap between laboratory data and real-world performance.
Commercial golf glove effects on golf performance and forearm muscle activity.
Sorbie, Graeme G; Darroch, Paul; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike C
2017-01-01
The study aimed to determine whether or not commercial golf gloves influence performance variables and forearm muscle activity during golf play. Fifteen golfers participated in the laboratory based study, each performing 8 golf swings with a Driver and 7-iron whilst wearing a glove and 8 without wearing the glove. Club head speed, ball speed and absolute carry distance performance variables were calculated. Surface electromyography was recorded from the flexor digitorum superficialis and extensor carpi radialis brevis on both forearm muscles. Club head speed, ball speed and absolute carry distance was significantly higher when using the Driver with the glove in comparison to the Driver without the glove (p < 0.05). No significant differences were evident when using the 7-iron and no significant differences were displayed in muscle activity in either of the conditions. Findings from this study suggest that driving performance is improved when wearing a glove.
Smart glove: hand master using magnetorheological fluid actuators
NASA Astrophysics Data System (ADS)
Nam, Y. J.; Park, M. K.; Yamane, R.
2007-12-01
In this study, a hand master using five miniature magneto-rheological (MR) actuators, which is called 'the smart glove', is introduced. This hand master is intended to display haptic feedback to the fingertip of the human user interacting with any virtual objects in virtual environment. For the smart glove, two effective approaches are proposed: (i) by using the MR actuator which can be considered as a passive actuator, the smart glove is made simple in structure, high in power, low in inertia, safe in interface and stable in haptic feedback, and (ii) with a novel flexible link mechanism designed for the position-force transmission between the fingertips and the actuators, the number of the actuator and the weight of the smart glove can be reduced. These features lead to the improvement in the manipulability and portability of the smart glove. The feasibility of the constructed smart glove is verified through basic performance evaluation.
Effect of shelf aging on vibration transmissibility of anti-vibration gloves
SHIBATA, Nobuyuki
2017-01-01
Anti-vibration gloves have been used in real workplaces to reduce vibration transmitted through hand-held power tools to the hand. Generally materials used for vibration attenuation in gloves are resilient materials composed of certain synthetic and/or composite polymers. The mechanical characteristics of the resilient materials used in anti-vibration gloves are prone to be influenced by environmental conditions such as temperature, humidity, and photo-irradiation, which cause material degradation and aging. This study focused on the influence of shelf aging on the vibration attenuation performance of air-packaged anti-vibration gloves following 2 yr of shelf aging. Effects of shelf aging on the vibration attenuation performance of anti-vibration gloves were examined according to the Japan industrial standard JIS T8114 test protocol. The findings indicate that shelf aging induces the reduction of vibration attenuation performance in air-packaged anti-vibration gloves. PMID:28978817
Hewitt, Sue; Dong, Ren G; Welcome, Daniel E; McDowell, Thomas W
2015-03-01
For exposure to hand-transmitted vibration (HTV), personal protective equipment is sold in the form of anti-vibration (AV) gloves, but it remains unclear how much these gloves actually reduce vibration exposure or prevent the development of hand-arm vibration syndrome in the workplace. This commentary describes some of the issues that surround the classification of AV gloves, the assessment of their effectiveness and their applicability in the workplace. The available information shows that AV gloves are unreliable as devices for controlling HTV exposures. Other means of vibration control, such as using alternative production techniques, low-vibration machinery, routine preventative maintenance regimes, and controlling exposure durations are far more likely to deliver effective vibration reductions and should be implemented. Furthermore, AV gloves may introduce some adverse effects such as increasing grip force and reducing manual dexterity. Therefore, one should balance the benefits of AV gloves and their potential adverse effects if their use is considered. © Crown copyright 2014.
Comparison of positive pressure gloves on hand function in adults with burns.
O'Brien, Kimberly A; Weinstock-Zlotnick, Gwen; Hunter, Hope; Yurt, Roger W
2006-01-01
The purpose of this study was to analyze the impact of a standard, custom-made pressure glove vs The NewYork-Presbyterian Dexterity Glove (NYPDG) with silon application on the palmer surface on functional hand use of burn survivors. A standard, custom-made pressure glove and NYPDG were given to 18 participants in a randomized order. Subjects wore each glove for 7 to 10 days during all activities of daily living (ADL). Variables such as hand function, difficulty of fine and gross motor ADL, and participant glove preference were assessed with each glove condition. Data collection of the second glove took place 7 to 10 days later incorporating a quasiexperimental, repeated measure design. A crossover design was used to analyze the data. The NYPDG demonstrated significantly better results in all of the four outcome categories measured: time to complete the Jebsen, the Jebsen Likert scale, fine motor ADL, and gross motor ADL. This study demonstrated that functional tasks took less time to complete and were more easily performed when using the NYPDG.
A new methodology for the assessment of hand protection from ultraviolet exposure.
Khazova, M; O'Hagan, J B; Grainger, K J-L
2006-01-01
A number of industrial applications and public services involve occupational exposure to ultraviolet radiation (UVR) from a variety of lamps and lasers. The aim of this study was to develop a methodology for the assessment of the UV protection level for disposable gloves. Glove UV protection factor is defined as a time-scale increase in exposure permitted for the hand protected by a glove with respect to an unprotected hand. Our study showed that for all tested gloves a change in UVR attenuation with stretching is characteristic for the type of glove material and can be included as a scaling factor in the definition of UVR protection. Glove material has a bigger effect on UVR protection level than variations in the glove thickness or its colour. Examples of assessment of the 'worst case scenario' are compared with the protection level against a number of sources, together with the guidance on a simplified evaluation protocol. An application-specific assessment, illustrated for 'SmartWater' forensic examinations and biological trans-illuminators, demonstrates that some gloves provide inadequate protection against occupational UV exposure.
Design and Characterization of a Soft Robotic Therapeutic Glove for Rheumatoid Arthritis.
Chua, Matthew Chin Heng; Lim, Jeong Hoon; Yeow, Raye Chen Hua
2017-07-27
The modeling and experimentation of a pneumatic actuation system for the development of a soft robotic therapeutic glove is proposed in this article for the prevention of finger deformities in rheumatoid arthritis (RA) patients. The Rehabilitative Arthritis Glove (RA-Glove) is a soft robotic glove fitted with two internal inflatable actuators for lateral compression and massage of the fingers and their joints. Two mechanical models to predict the indentation and bending characteristics of the inflatable actuators based on their geometrical parameters will be presented and validated with experimental results. Experimental validation shows that the model was within a standard deviation of the experimental mean for input pressure range of 0 to 2 bars. Evaluation of the RA-Glove was also performed on six healthy human subjects. The stress distribution along the fingers of the subjects using the RA-Glove was also shown to be even and specific to the finger sizes. This article demonstrates the modeling of soft pneumatic actuators and highlights the potential of the RA-Glove as a therapeutic device for the prevention of arthritic deformities of the fingers.
The Hayabusa Curation Facility at Johnson Space Center
NASA Technical Reports Server (NTRS)
Zolensky, M.; Bastien, R.; McCann, B.; Frank, D.; Gonzalez, C.; Rodriguez, M.
2013-01-01
The Japan Aerospace Exploration Agency (JAXA) Hayabusa spacecraft made contact with the asteroid 25143 Itokawa and collected regolith dust from Muses Sea region of smooth terrain [1]. The spacecraft returned to Earth with more than 10,000 grains ranging in size from just over 300 µm to less than 10 µm [2, 3]. These grains represent the only collection of material returned from an asteroid by a spacecraft. As part of the joint agreement between JAXA and NASA for the mission, 10% of the Hayabusa grains are being transferred to NASA for parallel curation and allocation. In order to properly receive process and curate these samples, a new curation facility was established at Johnson Space Center (JSC). Since the Hayabusa samples within the JAXA curation facility have been stored free from exposure to terrestrial atmosphere and contamination [4], one of the goals of the new NASA curation facility was to continue this treatment. An existing lab space at JSC was transformed into a 120 sq.ft. ISO class 4 (equivalent to the original class 10 standard) clean room. Hayabusa samples are stored, observed, processed, and packaged for allocation inside a stainless steel glove box under dry N2. Construction of the clean laboratory was completed in 2012. Currently, 25 Itokawa particles are lodged in NASA's Hayabusa Lab. Special care has been taken during lab construction to remove or contain materials that may contribute contaminant particles in the same size range as the Hayabusa grains. Several witness plates of various materials are installed around the clean lab and within the glove box to permit characterization of local contaminants at regular intervals by SEM and mass spectrometry, and particle counts of the lab environment are frequently acquired. Of particular interest is anodized aluminum, which contains copious sub-mm grains of a multitude of different materials embedded in its upper surface. Unfortunately the use of anodized aluminum was necessary in the construction of the clean room frame to strengthen it and eliminate corrosion and wear over time. All anodized aluminum interior to the lab was thus covered or replaced by minimally contaminating materials.
Effect of reducing groundwater on the retardation of redox-sensitive radionuclides
Hu, QH; Zavarin, M; Rose, TP
2008-01-01
Laboratory batch sorption experiments were used to investigate variations in the retardation behavior of redox-sensitive radionuclides. Water-rock compositions were designed to simulate subsurface conditions at the Nevada Test Site (NTS), where a suite of radionuclides were deposited as a result of underground nuclear testing. Experimental redox conditions were controlled by varying the oxygen content inside an enclosed glove box and by adding reductants into the testing solutions. Under atmospheric (oxidizing) conditions, radionuclide distribution coefficients varied with the mineralogic composition of the sorbent and the water chemistry. Under reducing conditions, distribution coefficients showed marked increases for 99Tc (from 1.22 at oxidizing to 378 mL/g at mildly reducing conditions) and 237Np (an increase from 4.6 to 930 mL/g) in devitrified tuff, but much smaller variations in alluvium, carbonate rock, and zeolitic tuff. This effect was particularly important for 99Tc, which tends to be mobile under oxidizing conditions. A review of the literature suggests that iodine sorption should decrease under reducing conditions when I- is the predominant species; this was not consistently observed in batch tests. Overall, sorption of U to alluvium, devitrified tuff, and zeolitic tuff under atmospheric conditions was less than in the glove-box tests. However, the mildly reducing conditions achieved here were not likely to result in substantial U(VI) reduction to U(IV). Sorption of Pu was not affected by the decreasing Eh conditions achieved in this study, as the predominant sorbed Pu species in all conditions was expected to be the low-solubility and strongly sorbing Pu(OH)4. Depending on the aquifer lithology, the occurrence of reducing conditions along a groundwater flowpath could potentially contribute to the retardation of redox-sensitive radionuclides 99Tc and 237Np, which are commonly identified as long-term dose contributors in the risk assessment in various radionuclide environmental contamination scenarios. The implications for increased sorption of 99Tc and 237Np to devitrified tuff under reducing conditions are significant as the fractured devitrified tuff serves as important water flow path at the NTS and the horizon for a proposed repository to store high-level nuclear waste at Yucca Mountain. PMID:19077277
Examining the Usefulness of ISO 10819 Anti-Vibration Glove Certification.
Budd, Diandra; House, Ron
2017-03-01
Anti-vibration gloves are commonly worn to reduce hand-arm vibration exposure from work with hand-held vibrating tools when higher priority and more effective controls are unavailable. For gloves to be marketed as 'anti-vibration' they must meet the vibration transmissibility criteria described in the International Organization for Standardization (ISO) standard 10819 (2013). Several issues exist with respect to the methodology used for glove testing as well as the requirements for glove design and composition in ISO 10819 (2013). The true usefulness of anti-vibration gloves at preventing hand-arm vibration syndrome (HAVS) is controversial, given that their performance is dependent on tool vibration characteristics and the anthropometrics of workers in real working conditions. The major risk associated with the use of anti-vibration gloves is that it will give employees and employers a false sense of protection against the negative effects of hand-transmitted vibration. This commentary examines the limitations of the current international standards for anti-vibration glove testing and certification, thereby calling into question the degree of protection that anti-vibration gloves provide against HAVS, and cautioning users to consider both their benefits and potential drawbacks on a case-by-case basis. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Transmission of vibration through gloves: effects of contact area.
Md Rezali, Khairil Anas; Griffin, Michael J
2017-01-01
For three samples of material (12.5, 25.0 and 37.5 mm diameter) from each of three gloves, the dynamic stiffnesses and the vibration transmissibilities of the materials (to both the palm of the hand and the thenar eminence) were measured at frequencies from 10 to 300 Hz. Additional measurements showed the apparent masses of the hand at the palm and the thenar eminence were independent of contact area at frequencies less than about 40 Hz, but increased with increasing area at higher frequencies. The stiffness and damping of the glove materials increased with increasing area. These changes caused material transmissibilities to the hand to increase with increasing area. It is concluded that the size of the area of contact has a large influence on the transmission of vibration through a glove to the hand. The area of contact should be well-defined and controlled when evaluating the transmission of vibration through gloves. Practitioner Summary: The transmission of vibration through gloves depends on both the dynamic stiffness of glove material and the dynamic response of the hand. Both of these depend on the size of the contact area between a glove material and the hand, which should be taken into account when assessing glove transmissibility.
Transmission of vibration through glove materials: effects of contact force.
Md Rezali, Khairil Anas; Griffin, Michael J
2018-04-26
This study investigated effects of applied force on the apparent mass of the hand, the dynamic stiffness of glove materials and the transmission of vibration through gloves to the hand. For 10 subjects, 3 glove materials and 3 contact forces, apparent masses and glove transmissibilities were measured at the palm and at a finger at frequencies in the range 5-300 Hz. The dynamic stiffnesses of the materials were also measured. With increasing force, the dynamic stiffnesses of the materials increased, the apparent mass at the palm increased at frequencies greater than the resonance and the apparent mass at the finger increased at low frequencies. The effects of force on transmissibilities therefore differed between materials and depended on vibration frequency, but changes in apparent mass and dynamic stiffness had predictable effects on material transmissibility. Depending on the glove material, the transmission of vibration through a glove can be increased or decreased when increasing the applied force. Practitioner summary: Increasing the contact force (i.e. push force or grip force) can increase or decrease the transmission of vibration through a glove. The vibration transmissibilities of gloves should be assessed with a range of contact forces to understand their likely influence on the exposure of the hand and fingers to vibration.
Computational Optimization of a Natural Laminar Flow Experimental Wing Glove
NASA Technical Reports Server (NTRS)
Hartshom, Fletcher
2012-01-01
Computational optimization of a natural laminar flow experimental wing glove that is mounted on a business jet is presented and discussed. The process of designing a laminar flow wing glove starts with creating a two-dimensional optimized airfoil and then lofting it into a three-dimensional wing glove section. The airfoil design process does not consider the three dimensional flow effects such as cross flow due wing sweep as well as engine and body interference. Therefore, once an initial glove geometry is created from the airfoil, the three dimensional wing glove has to be optimized to ensure that the desired extent of laminar flow is maintained over the entire glove. TRANAIR, a non-linear full potential solver with a coupled boundary layer code was used as the main tool in the design and optimization process of the three-dimensional glove shape. The optimization process uses the Class-Shape-Transformation method to perturb the geometry with geometric constraints that allow for a 2-in clearance from the main wing. The three-dimensional glove shape was optimized with the objective of having a spanwise uniform pressure distribution that matches the optimized two-dimensional pressure distribution as closely as possible. Results show that with the appropriate inputs, the optimizer is able to match the two dimensional pressure distributions practically across the entire span of the wing glove. This allows for the experiment to have a much higher probability of having a large extent of natural laminar flow in flight.
Practice and attitudes regarding double gloving among staff surgeons and surgical trainees.
Lipson, Mark E; Deardon, Rob; Switzer, Noah J; de Gara, Chris; Ball, Chad G; Grondin, Sean C
2018-06-01
Despite supporting evidence, many staff surgeons and surgical trainees do not routinely double glove. We performed a study to assess rates of and attitudes toward double gloving and the use of eye protection in the operating room. We conducted an electronic survey among all staff surgeons and surgical trainees at 2 tertiary care centres in Alberta between September and November 2015.We analyzed the data using log-binomial regression for binary outcomes to account for multiple independent variables and interactions. For 2-group comparisons, we used a 2-group test of proportions. The response rate was 34.3% (361/1051); 205/698 staff surgeons (29.4%) and 156/353 surgical trainees (44.2%) responded. Trainees were more likely than staff surgeons to ever double glove in the operating room ( p = 0.01) and to do so routinely ( p = 0.01). Staff surgeons were more likely than trainees to never double glove ( p = 0.01). A total of 300/353 respondents (85.0%) reported using eye protection routinely in the operating room. Needle-stick injury was common (184 staff surgeons [92.5%], 115 trainees [74.7%]). Reduced tactile feedback, decreased manual dexterity and discomfort/poor fit were perceived barriers to double gloving. Rates of double gloving leave room for improvement. Surgical trainees were more likely than staff surgeons to double glove. Barriers remain to routine double gloving among staff surgeons and trainees. Increased education on the benefits of double gloving and early introduction of this practice may increase uptake.
Furlong, Melissa; Tanner, Caroline M; Goldman, Samuel M; Bhudhikanok, Grace S.; Blair, Aaron; Chade, Anabel; Comyns, Kathleen; Hoppin, Jane A.; Kasten, Meike; Korell, Monica; Langston, J William; Marras, Connie; Meng, Cheryl; Richards, Marie; Ross, G Webster; Umbach, David M; Sandler, Dale P; Kamel, Freya
2014-01-01
Pesticides have been associated with Parkinson’s disease (PD), and protective gloves and workplace hygiene can reduce pesticide exposure. We assessed whether use of gloves and workplace hygiene modified associations between pesticides and PD. The Farming and Movement Evaluation (FAME) Study is a nested case-control study within the Agricultural Health Study. Use of protective gloves, other PPE, and hygiene practices were determined by questionnaire (69 cases and 237 controls were included). We considered interactions of gloves and hygiene with ever-use of pesticides for all pesticides with ≥ 5 exposed and unexposed cases and controls in each glove-use stratum (paraquat, permethrin, rotenone, and trifluralin). 61% of respondents consistently used protective gloves and 87% consistently used ≥ 2 hygiene practices. Protective glove use modified the associations of paraquat and permethrin with PD: neither pesticide was associated with PD among protective glove users, while both pesticides were associated with PD among non-users (paraquat OR 3.9 [95% CI 1.3, 11.7], interaction p=0.15; permethrin OR 4.3 [95% CI 1.2, 15.6] interaction p=0.05). Rotenone was associated with PD regardless of glove use. Trifluralin was associated with PD among people who used <2 hygiene practices (OR 5.5 [95% CI 1.1, 27.1]) but was not associated with PD among people who used 2 or more practices (interaction p=0.02). Although sample size was limited in the FAME study, protective glove use and hygiene practices appeared to be important modifiers of the association between pesticides and PD and may reduce risk of PD associated with certain pesticides. PMID:25461423
Spacesuit Glove-Induced Hand Trauma and Analysis of Potentially Related Risk Variables
NASA Technical Reports Server (NTRS)
Charvat, Chacqueline M.; Norcross, Jason; Reid, Christopher R.; McFarland, Shane M.
2015-01-01
Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. Glove injuries, both anecdotal and recorded, have been reported during EVA training and flight persistently through NASA's history regardless of mission or glove model. Theories as to causation such as glove-hand fit are common but often lacking in supporting evidence. Previous statistical analysis has evaluated onycholysis in the context of crew anthropometry only. The purpose of this study was to analyze all injuries (as documented in the medical records) and available risk factor variables with the goal to determine engineering and operational controls that may reduce hand injuries due to the EVA glove in the future. A literature review and data mining study were conducted between 2012 and 2014. This study included 179 US NASA crew who trained or completed an EVA between 1981 and 2010 (crossing both Shuttle and ISS eras) and wore either the 4000 Series or Phase VI glove during Extravehicular Mobility Unit (EMU) spacesuit EVA training and flight. All injuries recorded in medical records were analyzed in their association to candidate risk factor variables. Those risk factor variables included demographic characteristics, hand anthropometry, glove fit characteristics, and training/EVA characteristics. Utilizing literature, medical records and anecdotal causation comments recorded in crewmember injury data, investigators were able to identify several risk factors associated with increased risk of glove related injuries. Prime among them were smaller hand anthropometry, duration of individual suited exposures, and improper glove-hand fit as calculated by the difference in the anthropometry middle finger length compared to the baseline EVA glove middle finger length.
Dexterity tests data contribute to reduction in leaded glovebox gloves use
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cournoyer, Michael E; Lawton, Cindy M; Castro, Amanda M
2008-01-01
Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alphaemitting materials. The spread of radiological contamination on surfaces and airborne contamination and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Through an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program (GGJP). A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management owning glovebox processes through this program make decisions onmore » which type of glovebox gloves (the weakest component of this safety significant system) would perform in these aggressive environments. As Low As Reasonably Achievable (ALARA) considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) glovebox gloves made from Hypalon(reg.) had been the workhorse of programmatic operations at TA-55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduced the amount of mixed TRU waste. This effort contributes to Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations. In the following report, the pros and cons of wearing leaded glovebox gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and pollution prevention benefits of this dramatic change in the glovebox system are presented.« less
Furlong, Melissa; Tanner, Caroline M; Goldman, Samuel M; Bhudhikanok, Grace S; Blair, Aaron; Chade, Anabel; Comyns, Kathleen; Hoppin, Jane A; Kasten, Meike; Korell, Monica; Langston, J William; Marras, Connie; Meng, Cheryl; Richards, Marie; Ross, G Webster; Umbach, David M; Sandler, Dale P; Kamel, Freya
2015-02-01
Pesticides have been associated with Parkinson's disease (PD), and protective gloves and workplace hygiene can reduce pesticide exposure. We assessed whether use of gloves and workplace hygiene modified associations between pesticides and PD. The Farming and Movement Evaluation (FAME) study is a nested case-control study within the Agricultural Health Study. Use of protective gloves, other PPE, and hygiene practices were determined by questionnaire (69 cases and 237 controls were included). We considered interactions of gloves and hygiene with ever-use of pesticides for all pesticides with ≥5 exposed and unexposed cases and controls in each glove-use stratum (paraquat, permethrin, rotenone, and trifluralin). 61% of respondents consistently used protective gloves and 87% consistently used ≥2 hygiene practices. Protective glove use modified the associations of paraquat and permethrin with PD: neither pesticide was associated with PD among protective glove users, while both pesticides were associated with PD among non-users (paraquat OR 3.9 [95% CI 1.3, 11.7], interaction p=0.15; permethrin OR 4.3 [95% CI 1.2, 15.6] interaction p=0.05). Rotenone was associated with PD regardless of glove use. Trifluralin was associated with PD among participants who used <2 hygiene practices (OR 5.5 [95% CI 1.1, 27.1]) but was not associated with PD among participants who used 2 or more practices (interaction p=0.02). Although sample size was limited in the FAME study, protective glove use and hygiene practices appeared to be important modifiers of the association between pesticides and PD and may reduce risk of PD associated with certain pesticides. Published by Elsevier Ltd.
Spacesuit Glove-Induced Hand Trauma and Analysis of Potentially Related Risk Variables
NASA Technical Reports Server (NTRS)
McFarland, Shane M.; Reid, Christopher R.; Norcross, Jason; Charvat, Jacqueline M.
2015-01-01
Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. Glove injuries, both anecdotal and recorded, have been reported during EVA training and flight persistently through NASA's history regardless of mission or glove model. Theories as to causation such as glove-hand fit are common but often lacking in supporting evidence. Previous statistical analysis has evaluated onycholysis in the context of crew anthropometry only (Opperman et al 2010). The purpose of this study was to analyze all injuries (as documented in the medical records) and available risk factor variables with the goal to determine engineering and operational controls that may reduce hand injuries due to the EVA glove in the future. A literature review and data mining study were conducted between 2012 and 2014. This study included 179 US NASA crew who trained or completed an EVA between 1981 and 2010 (crossing both Shuttle and ISS eras) and wore either the 4000 Series or Phase VI glove during Extravehicular Mobility Unit (EMU) spacesuit EVA training and flight. All injuries recorded in medical records were analyzed in their association to candidate risk factor variables. Those risk factor variables included demographic characteristics, hand anthropometry, glove fit characteristics, and training/EVA characteristics. Utilizing literature, medical records and anecdotal causation comments recorded in crewmember injury data, investigators were able to identify several risk factors associated with increased risk of glove related injuries. Prime among them were smaller hand anthropometry, duration of individual suited exposures, and improper glove-hand fit as calculated by the difference in the anthropometry middle finger length compared to the baseline EVA glove middle finger length.
Glove and mitten protection in extreme cold weather: an Antarctic study.
Iserson, Kenneth V
2016-01-01
Background Myths, misconceptions and a general lack of information surround the use of gloves and mittens in extreme cold environments. Objective This study assessed how well an assortment of gloves and mittens performed in a very cold environment. Methods A convenience sample of gloves and mittens were tested in Antarctica during the winter of 2016 using a calibrated thermometer (range: -148°F to +158°F/-100°C to +70°C) three times over a 0.5-mile distance (~20 minutes). A small sensor on a 10-foot-long cable was taped to the radial surface of the distal small finger on the non-dominant hand. The tested clothing was donned over the probe, the maximum temperature inside the glove/mitten was established near a building exit (ambient temperature approximately 54°F/12°C), and the building was exited, initiating the test. The hand was kept immobile during the test. Some non-heated gloves were tested with chemical heat warmers placed over the volar or dorsal wrist. Results The highest starting (96°F/36°C) and ending (82°F/28°C) temperatures were with electrically heated gloves. The lowest starting temperature was with electrically heated gloves with the power off (63°F/17°C). Non-heated gloves with an inserted chemical hand warmer had the lowest minimum temperature (33°F/1°C). Maximum temperatures for gloves/mittens did not correlate well with their minimum temperature. Conclusions Coverings that maintained finger temperatures within a comfortable and safe range (at or above 59°F/15°C) included the heated gloves and mittens (including some with the power off) and mittens with liners. Mittens without liners (shell) generally performed better than unheated gloves. Better results generally paralleled the item's cost. Inserting chemical heat warmers at the wrist increased heat loss, possibly through the exposed area around the warmer.
Glove and mitten protection in extreme cold weather: an Antarctic study.
Iserson, Kenneth V
2016-01-01
Myths, misconceptions and a general lack of information surround the use of gloves and mittens in extreme cold environments. This study assessed how well an assortment of gloves and mittens performed in a very cold environment. A convenience sample of gloves and mittens were tested in Antarctica during the winter of 2016 using a calibrated thermometer (range: -148°F to +158°F/-100°C to +70°C) three times over a 0.5-mile distance (~20 minutes). A small sensor on a 10-foot-long cable was taped to the radial surface of the distal small finger on the non-dominant hand. The tested clothing was donned over the probe, the maximum temperature inside the glove/mitten was established near a building exit (ambient temperature approximately 54°F/12°C), and the building was exited, initiating the test. The hand was kept immobile during the test. Some non-heated gloves were tested with chemical heat warmers placed over the volar or dorsal wrist. The highest starting (96°F/36°C) and ending (82°F/28°C) temperatures were with electrically heated gloves. The lowest starting temperature was with electrically heated gloves with the power off (63°F/17°C). Non-heated gloves with an inserted chemical hand warmer had the lowest minimum temperature (33°F/1°C). Maximum temperatures for gloves/mittens did not correlate well with their minimum temperature. Coverings that maintained finger temperatures within a comfortable and safe range (at or above 59°F/15°C) included the heated gloves and mittens (including some with the power off) and mittens with liners. Mittens without liners (shell) generally performed better than unheated gloves. Better results generally paralleled the item's cost. Inserting chemical heat warmers at the wrist increased heat loss, possibly through the exposed area around the warmer.
NASA Technical Reports Server (NTRS)
Koscheyev, Victor S.; Leon, Gloria R.; Trevino, Robert C.
2000-01-01
This study explored the effectiveness of local wrist/palm warming as a potential countermeasure for providing finger comfort during extended duration EVA. Methods: Six subjects (5 males and 1 female) were evaluated in a sagitally divided liquid cooling/warming garment (LCWG) with modified liquid cooling/warming (LCW) gloves in three different experimental conditions. Condition 1: Stage 1- no LCWG; chamber adaptation with LCW glove inlet water temperature 33 C; Stage 2-LCW glove inlet water temperature cooled to 8 C; Stage 3-LCW glove inlet water temperature warmed to 45 C; Condition 2: Stage1-LCWG and LCW glove inlet water temperature 33 C; Stage 2-LCWG inlet temperature cooled to 31 C, LCW gloves, 8 C; Stage 3-LCWG inlet water temperature remains at 31 C, LCW glove inlet water temperature warmed to 45 C; Condition 3: Stage l -LCWG and LCW gloves 33 C; Stage 2-LCWG inlet water temperature cooled to 28 C, LCW gloves, 8 C; Stage 3-LCWG remains at 28 C, LCW glove water temperature warmed to 45 C. Results: Wrist/palm area warming significantly increased finger temperature (Tfing) and blood perfusion in Stage 3 compared to Stage 2. The LCW gloves were most effective in increasing Stage 3 Tfing in Condition 1; and in increasing blood perfusion in Conditions 1 and 2 compared to Condition 3. Ratings of subjective perception of heat in the hand and overall body heat were higher at Stage 3 than Stage 2, with no significant differences across Conditions. Conclusions: Local wrist/palm warming was effective in increasing blood circulation to the distal extremities, suggesting the potential usefulness of this technique for increasing astronaut thermal comfort during EVA while decreasing power requirements. The LCW gloves were effective in heating the highly cooled fingers when the overall body was in a mild heat deficit.
Hand washing and use of gloves while managing patients receiving mechanical ventilation in the ICU.
Khatib, M; Jamaleddine, G; Abdallah, A; Ibrahim, Y
1999-07-01
To evaluate the effectiveness of warning labels permanently attached to mechanical ventilators in improving the practice of hand washing and use of gloves by respiratory care practitioners (RCPs) in the ICU. The study consisted of two 4-week periods. Daily observations of hand washing and use of gloves by RCPs were made over four 1-h observation periods. Prior to the first 4-week period, the importance of hand washing and use of gloves was presented to all staff. At the end of the first period, "Wash Hands Use Gloves" labels were permanently placed on all ventilators in the ICU. The RCPs were not aware they were being observed for hand washing and use of gloves in either period. The total number of encounters between the RCPs and patients as well as the rates of hand washing and use of gloves were obtained during the study. The rates of hand washing and use of gloves were significantly higher during the second period when labels were attached to the ventilators, as compared to the rates during the first period: hand washing, 92% vs 46% (p < 0.05); use of gloves, 92% vs 43% (p < 0.05), respectively. During the first period, the rates of pre-encounter hand washing (78%, 48%, 27%, and 29% in weeks 1 through 4, respectively) and the use of gloves (56%, 37%, 32%, and 45% in weeks 1 through 4, respectively) were primarily declining. This was not observed during the second period of the study (94%, 88%, 95%, and 92% in weeks 1 through 4, respectively) for the rates of pre-encounter hand washing and the use of gloves. Simple measures such as the placement of warning labels on mechanical ventilators can significantly improve hand washing and use of gloves by RCPs in the ICU.
Phase VI Glove Durability Testing
NASA Technical Reports Server (NTRS)
Mitchell, Kathryn
2011-01-01
The current state-of-the-art space suit gloves, the Phase VI gloves, have an operational life of 25 -- 8 hour Extravehicular Activities (EVAs) in a dust free, manufactured microgravity EVA environment. Future planetary outpost missions create the need for space suit gloves which can endure up to 90 -- 8 hour traditional EVAs or 576 -- 45 minute suit port-based EVAs in a dirty, uncontrolled planetary environment. Prior to developing improved space suit gloves for use in planetary environments, it is necessary to understand how the current state-of-the-art performs in these environments. The Phase VI glove operational life has traditionally been certified through cycle testing consisting of International Space Station (ISS)-based EVA tasks in a clean environment, and glove durability while performing planetary EVA tasks in a dirty environment has not previously been characterized. Testing was performed in the spring of 2010 by the NASA Johnson Space Center (JSC) Crew and Thermal Systems Division (CTSD) to characterize the durability of the Phase VI Glove and identify areas of the glove design which need improvement to meet the requirements of future NASA missions. Lunar simulant was used in this test to help replicate the dirty lunar environment, and generic planetary surface EVA tasks were performed during testing. A total of 50 manned, pressurized test sessions were completed in the Extravehicular Mobility Unit (EMU) using one pair of Phase VI gloves as the test article. The 50 test sessions were designed to mimic the total amount of pressurized cycling the gloves would experience over a 6 month planetary outpost mission. The gloves were inspected periodically throughout testing, to assess their condition at various stages in the test and to monitor the gloves for failures. Additionally, motion capture and force data were collected during 18 of the 50 test sessions to assess the accuracy of the cycle model predictions used in testing and to feed into the development of improved cycle model tables. This paper provides a detailed description of the test hardware and methodology, shares the results of the testing, and provides recommendations for future work.
Incidence and patterns of surgical glove perforations: experience from Addis Ababa, Ethiopia.
Bekele, Abebe; Makonnen, Nardos; Tesfaye, Lidya; Taye, Mulat
2017-03-20
Surgical glove perforation is a common event. The operating staff is not aware of the perforation until the procedure is complete, sometimes in as high as 70% of the incidences. Data from Ethiopia indicates that the surgical workforce suffers from a very surgery related accidents, however there is paucity of data regarding surgical glove perforation. The main objective is to describe the incidence and patterns of surgical glove perforation during surgical procedures and to compare the rates between emergency and elective surgeries at one of the main hospitals in Addis Ababa Ethiopia. This is a prospective study, performed at the Minilik II referral hospital, Addis Ababa. All surgical gloves worn during all major surgical procedures (Emergency and Elective) from June 1-July 20, 2016 were collected and used for the study. Standardised visual and hydro insufflation techniques were used to test the gloves for perforations. Parameters recorded included type of procedure performed, number of perforations, localisation of perforation and the roles of the surgical team. A total of 2634 gloves were tested, 1588 from elective and 1026 from emergency procedures. The total rate of perforation in emergency procedures was 41.4%, while perforation in elective surgeries was 30.0%. A statistically significant difference (P < 0.05) was found in between emergency and elective surgeries. There were a very high rate of perforations of gloves among first surgeons 40.6% and scrub nurses 38.8% during elective procedures and among first surgeons (60.14%), and second assistants (53.0%) during emergency surgeries. Only 0.4% of inner gloves were perforated. The left hand, the left index finger and thumb were the most commonly perforated parts of the glove. Glove perforation rate was low among consultant surgeons than residents. Our reported perforation rate is higher than most publications, and this shows that the surgical workforce in Ethiopia is under a clear and present threat. Measures such as double gloving seems to have effectively prevented cutaneous blood exposure and thus should become a routine for all surgical procedures. Manufacturing related defects and faults in glove quality may also be contributing factors.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunodeficiency virus (HIV), which causes acquired immune deficiency syndrome (AIDS), and its risk of transmission... (collectively known as medical gloves) to reduce the risk of transmission of HIV and other blood-borne... gloves to reduce the risk of transmission of HIV and other blood-borne infectious deseases. The CDC...
Code of Federal Regulations, 2013 CFR
2013-04-01
... immunodeficiency virus (HIV), which causes acquired immune deficiency syndrome (AIDS), and its risk of transmission... (collectively known as medical gloves) to reduce the risk of transmission of HIV and other blood-borne... gloves to reduce the risk of transmission of HIV and other blood-borne infectious deseases. The CDC...
Code of Federal Regulations, 2012 CFR
2012-04-01
... immunodeficiency virus (HIV), which causes acquired immune deficiency syndrome (AIDS), and its risk of transmission... (collectively known as medical gloves) to reduce the risk of transmission of HIV and other blood-borne... gloves to reduce the risk of transmission of HIV and other blood-borne infectious deseases. The CDC...
Code of Federal Regulations, 2014 CFR
2014-04-01
... immunodeficiency virus (HIV), which causes acquired immune deficiency syndrome (AIDS), and its risk of transmission... (collectively known as medical gloves) to reduce the risk of transmission of HIV and other blood-borne... gloves to reduce the risk of transmission of HIV and other blood-borne infectious deseases. The CDC...
Dexterity testing of chemical-defense gloves. Technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinette, K.M.; Ervin; Zehner, G.F.
1986-05-01
Chemical-defense gloves (12.5-mil Epichlorohydron/Butyl, 14-mil Epichlorohydron/Butyl, and 7-mil Butyl with Nomex overgloves) were subjected to four dexterity tests (O'Connor Finger Dexterity Test, Pennsylvania Bi-Manual Worksample-Assembly, Minnesota Rate of Manipulation Turning, and the Crawford Small Test). Results indicated that subjects performances were most impaired by the 7-mil Butyl with Nomex overglove. Though differences between the other three gloved conditions were not always statistically significant, subjects performed silghtly better while wearing the Epichlorohydron/Butyl gloves, no matter which thickness, than they did while wearing the 15-mil butyl gloves. High negative correlation between anthropometry and gloved tests scores of subjects suggested that poor glovemore » fit may also have affected subjects performances.« less
Peregrina, Alejandro; Land, Martin F; Feil, Phillip; Price, Connie
2003-09-01
Polymerization inhibition of polyvinylsiloxane impression materials has been reported when in sustained contact with some types of latex gloves. This study examined the polymerization inhibition of 3 polyvinylsiloxane impression materials placed in contact with surfaces subjected to prior contact with gloves or commonly used surfactants. A 2 x 3 x 4 x 2 design was used (n = 20), with 2 types of gloves (powdered and unpowdered), 3 types of polyvinylsiloxane impression materials (Aquasil, Extrude, and Affinis), 4 surfactant conditions (water, soap/water-rinse, alcohol, and unexposed), and 2 ambient temperatures of 22 degrees C and 36 degrees C. After glove exposure to surfactants, a glass surface was subjected to rubbing contact with the treated glove for a standardized time. After drying, automixed polyvinylsiloxane impression materials were dispensed onto the treated surface. Specimens were removed and evaluated for polymerization inhibition at the manufacturer's recommended polymerization time (36 degrees C), or after 15 minutes at 22 degrees C. Specimens were rated as polymerized, or as inhibited if any polyvinylsiloxane residue remained on the slab. A chi-square analysis was used to evaluate the results (alpha=.05). Setting inhibition was found only with one of the polyvinylsiloxane materials when alcohol was used as a surfactant. At 22 degrees C, the inhibition rate ranged from 95% to 100% for both glove types; at 36 degrees C inhibition ranged from 40% (unpowdered gloves) to 75% (powdered gloves), respectively. Under these in vitro conditions, glove exposure to alcohol resulted in polymerization inhibition of 1 of 3 tested polyvinylsiloxane impression materials (Extrude).
Piano jacket for perceiving and playing music for patients with cerebral palsy.
Lampe, Renée; Turova, Varvara; Alves-Pinto, Ana
2017-12-23
Patients with cerebral palsy with severe motor disabilities are limited not only in everyday life activities but also in choice of their hobbies. Playing a musical instrument is for the majority not possible, even though music constitutes a central component of many relaxation activities for people with disabilities. To give affected patients the opportunity to make music and to learn piano playing through somatosensory perception, a prototype of piano jacket was developed. A cycling jacket was equipped with boxes, each representing a musical note, incorporated into the sleeves. Each box contains vibration motors and LEDs. These can be used to translate the sequences of piano key presses performed at an external E-piano. An additional operation mode allows the user to actively play a melody himself by touching the same boxes that also incorporate touch sensor components. A working prototype of the piano jacket was developed. The sensory piano jacket provides patients with cerebral palsy and contractures the possibility to develop sensorimotor skills, motor abilities and participation in music-related activities. The jacket is planned to be used in music lessons. Implications for Rehabilitation The system is suitable even for patients with severe motor disabilities and especially joint contractures. Excellent handling through large easily accessible communication buttons. All building blocks are held in a garment, which allows for easy portability and gripping comfort.
Code of Federal Regulations, 2010 CFR
2010-04-01
... examination and by a water leak test method, using 1,000 milliliters (ml) of water. (i) Units examined. Each... inches up the fill tube.) (iii) Leak test examination. Immediately after adding the water, examine the glove for water leaks. Do not squeeze the glove; use only minimum manipulation to spread the fingers to...
ISMAIL, Ismaniza; GASKIN, Sharyn; PISANIELLO, Dino; EDWARDS, John W.
2017-01-01
Elbow length PVC gloves are often recommended for protection against organophosphorus pesticide (OP) exposure in agriculture. However, performance may be reduced due to high temperature, UV exposure and abrasion. We sought to assess these impacts for two OPs under normal use and reasonable worst-case scenarios. Glove permeation tests were conducted using ASTM cells with two PVC glove brands at 23°C and 45°C for up to 8 h. Technical grade dichlorvos and formulated diazinon were used undiluted and at application strength. Breakthough of undiluted dichlorvos occurred at both 23°C and 45°C, but only at 45°C for application strength. Breakthrough of diazinon was not achieved, except when undiluted at 45°C. UV-exposed and abraded gloves showed reduced performance, with the effect being approximately two-fold for dichlorvos. Only small differences were noted between glove brands. Extra precautions should be taken when handling concentrated OPs at high temperature, or when using abraded or sunlight-exposed gloves. PMID:29199264
Mitigation of EMU Cut Glove Hazard from Micrometeoroid and Orbital Debris Impacts on ISS Handrails
NASA Technical Reports Server (NTRS)
Ryan, Shannon; Christiansen, Eric L.; Davis, Bruce A.; Ordonez, Erick
2009-01-01
Recent cut damages sustained on crewmember gloves during extravehicular activity (ISS) onboard the International Space Station (ISS) have been caused by contact with sharp edges or a pinch point according to analysis of the damages. One potential source are protruding sharp edged crater lips from micrometeoroid and orbital debris (MMOD) impacts on metallic handrails along EVA translation paths. A number of hypervelocity impact tests were performed on ISS handrails, and found that mm-sized projectiles were capable of inducing crater lip heights two orders of magnitude above the minimum value for glove abrasion concerns. Two techniques were evaluated for mitigating the cut glove hazard of MMOD impacts on ISS handrails: flexible overwraps which act to limit contact between crewmember gloves and impact sites, and; alternate materials which form less hazardous impact crater profiles. In parallel with redesign efforts to increase the cut resilience of EMU gloves, the modifications to ISS handrails evaluated in this study provide the means to significantly reduce cut glove risk from MMOD impact craters
Edlich, Richard F; Mason, Shelley S; Swainston, Erin; Dahlstrom, Jill J; Gubler, K; Long, William B
2009-01-01
It has been well documented in the medical literature that powdered medical gloves can have serious consequences to patients and health-care workers. Adverse reactions to natural latex gloves, such as contact dermatitis and urticaria, occupational asthma, and anaphylaxis, have been documented as a significant cause of Workers' Compensation claims among health-care workers. While the cost of examination and surgical gloves is significant, this factor must be considered with the total cost of Workers' Compensation claims and possible litigation bestowed upon hospitals and glove manufacturing companies. In the United States, Canada, Belgium, and Germany, medical leaders have documented the dangers of powdered latex gloves and have implemented transition programs that are reducing Workers' Compensation claims filed by health-care workers. While attorneys view litigation against powdered glove manufacturers as the "next big tort", the authors of this article were not able to document all compensation costs to disabled workers because many settlements do not allow the claimant to disclose this information.
RoboGlove-A Grasp Assist Device for Earth and Space
NASA Technical Reports Server (NTRS)
Diftler, M. A.; Ihrke, C. A.; Bridgwater, L. B.; Rogers, J. M.; Davis, D. R.; Linn, D. M.; Laske, E. A.; Ensley, K. G.; Lee, J. H.
2015-01-01
The RoboGlove is an assistive device that can augment human strength, endurance or provide directed motion for use in rehabilitation. RoboGlove is a spinoff of the highly successful Robonaut 2 (R2) system developed as part of a partnership between General Motors and NASA. This extremely lightweight device employs an actuator system based on the R2 finger drive system to transfer part or the entire grasp load from human tendons to artificial ones contained in the glove. Steady state loads ranging from 15 to 20 lbs. and peaks approaching 50 lbs. are achievable. Work is underway to integrate the RoboGlove system with a space suit glove to add strength or reduce fatigue during spacewalks. Tactile sensing, miniaturized electronics, and on-board processing provide sufficient flexibility for applications in many industries. The following describes the design, mechanical/electrical integration, and control features of the glove in an assembly-line configuration and discusses work toward the space suit application.
Influence of surgical gloves on haptic perception thresholds.
Hatzfeld, Christian; Dorsch, Sarah; Neupert, Carsten; Kupnik, Mario
2018-02-01
Impairment of haptic perception by surgical gloves could reduce requirements on haptic systems for surgery. While grip forces and manipulation capabilities were not impaired in previous studies, no data is available for perception thresholds. Absolute and differential thresholds (20 dB above threshold) of 24 subjects were measured for frequencies of 25 and 250 Hz with a Ψ-method. Effects of wearing a surgical glove, moisture on the contact surface and subject's experience with gloves were incorporated in a full-factorial experimental design. Absolute thresholds of 12.8 dB and -29.6 dB (means for 25 and 250 Hz, respectively) and differential thresholds of -12.6 dB and -9.5 dB agree with previous studies. A relevant effect of the frequency on absolute thresholds was found. Comparisons of glove- and no-glove-conditions did not reveal a significant mean difference. Wearing a single surgical glove does not affect absolute and differential haptic perception thresholds. Copyright © 2017 John Wiley & Sons, Ltd.
Application of Spacesuit Glove Requirements Tools to Athletic and Personal Protective Equipment
NASA Technical Reports Server (NTRS)
England, Scott; Benson, Elizabeth; Melsoh, Miranda; Thompson, Shelby; Rajulu, Sudhakar
2010-01-01
Despite decades of ongoing improvement, astronauts must still struggle with inhibited dexterity and accelerated fatigue due to the requirement of wearing a pressurized Extra-Vehicular Activity (EVA) glove. Recent research in the Anthropometry and Biomechanics Facility at NASA's Johnson Space Center has focused on developing requirements for improvements in the design of the next generation of EVA glove. In the course of this research, it was decided to expand the scope of the testing to include a variety of commercially available athletic and consumer gloves to help provide a more recognizable comparison for investigators and designers to evaluate the current state of EVA glove mobility and strength. This comparison is being provided with the hope that innovative methods may help commercial development of gloves for various athletic and personal protective endeavors.
STS-107 Crew Equipment Interface Test (CEIT)activities at SPACEHAB
NASA Technical Reports Server (NTRS)
2001-01-01
KENNEDY SPACE CENTER, Fla. -- During Crew Equipment Interface Test activities at SPACEHAB, Cape Canaveral, Fla., STS-107 Mission Specialist Laurel Blair Salton Clark gets hands-on training on a glove box experiment inside the training module. As a research mission, STS-107 will carry the SPACEHAB Double Module in its first research flight into space and a broad collection of experiments ranging from material science to life science. CEIT activities enable the crew to perform certain flight operations, operate experiments in a flight-like environment, evaluate stowage locations and obtain additional exposure to specific experiment operations. Other STS-107 crew members are Commander Rick Douglas Husband; Pilot William C. McCool; Payload Commander Michael P. Anderson; Mission Specialists Kalpana Chawla and David M. Brown; and Payload Specialist Ilan Ramon, of Israel. STS-107 is scheduled for launch May 23, 2002
NASA Technical Reports Server (NTRS)
Yingst, R. A.; Cohen, B. A.; Ming, D. W.; Eppler, D. B.
2011-01-01
NASA's Desert Research and Technology Studies (D-RATS) field test is one of several analog tests that NASA conducts each year to combine operations development, technology advances and science under planetary surface conditions. The D-RATS focus is testing preliminary operational concepts for extravehicular activity (EVA) systems in the field using simulated surface operations and EVA hardware and procedures. For 2010 hardware included the Space Exploration Vehicles, Habitat Demonstration Units, Tri-ATHLETE, and a suite of new geology sample collection tools, including a self-contained GeoLab glove box for conducting in-field analysis of various collected rock samples. The D-RATS activities develop technical skills and experience for the mission planners, engineers, scientists, technicians, and astronauts responsible for realizing the goals of exploring planetary surfaces.
Electrodeposition and characterisation of Al-W alloy films from ionic liquid
NASA Astrophysics Data System (ADS)
Höhlich, D.; Wachner, D.; Müller, M.; Scharf, I.; Lampke, T.
2018-06-01
Al–W alloy films were prepared by electrodeposition using anhydrous 1-ethyl-3-methylimidazolium chloride (EMIMCl) ionic-liquid solution with aluminium chloride in a ratio of 1:1.5. As a commercially available tungsten precursor, tungsten hexachloride was used. The metal is dissolved in the ionic liquid at concentrations up to 0.06 mol/l. The deposition took place outside the glove box with a continuous argon stream over the electrolyte at a temperature of 60 °C with a current density of 1 A/m2. Resulting alloys show a tungsten content higher than 20 wt% (3.5 at%). The phase composition of Al-W alloys was observed by X-ray diffraction (XRD), and the chemical composition was characterised by scanning electron microscopy (SEM) and inductively-coupled plasma optical emission spectroscopy (ICP-OES).
How risky are pinholes in gloves? A rational appeal for the integrity of gloves for isolators.
Gessler, Angela; Stärk, Alexandra; Sigwarth, Volker; Moirandat, Claude
2011-01-01
Isolators provide a high degree of protection for the product and/or the environment and operators in pharmaceutical production, as well as for analytical and sterility testing. Gloves allow for performing testing and for easy access to the process. Due to their nature-thin plastic, highly flexible-and their risk of puncture or rupture, they are regarded as one of the main potential sources of contamination. Glove integrity testing is therefore a main issue and has been addressed by many regulations such as those imposed by the USP, U.S. Food and Drug Administration, and Pharmaceutical Inspection Convention. This paper presents a short overview of different glove integrity test procedures and their ability to detect leaking gloves. Additionally, extensive microbiological tests have been performed to give more evidence and cross-correlation to physical testing. Most of the physical tests have limitations either in detecting pinholes and/or they are difficult to implement for routine testing. Microbiological tests are only applicable for evaluation and validation purposes, but not for routine testing, because they are time-consuming and do not allow immediate action. Routine visual verification of gloves by trained personnel turns out to be a very reliable technique. Additional microbiological tests supported by microbiological environmental monitoring helped to develop a new concept presented here on how to handle gloves with pinholes. It is proposed not to automatically consider a pinhole in a glove as a breach in isolator integrity, but to consider any action in view of controlling and monitoring the effective bioload on the outside of the gloves. With the combination of semi-automatic physical testing with independent protocol, visual inspection, and control of bioload through microbiological environmental monitoring potential contamination, risks can be minimized and maximum safety maintained. Isolators are enclosure designs to protect critical handling and process steps in pharmaceutical environments. They provide a high degree of protection for product and/or environment and operators against particles, potentially hazardous active principles, and microbial load. Gloves mounted on windows and doors of the isolator allow for manipulation, performing testing, and access to the process. Due to their nature and their use with risk of puncture or rupture, they are regarded as a potential source for contamination. Glove integrity testing has therefor been addressed by regulations such as those imposed by the USP and the Food and Drug Administration. This paper presents a short overview of various glove integrity test procedures and their ability to detect leaking gloves. Most of the tests have limitations either in detecting pinholes and/or they are difficult to implement for routine testing. Routine visual verification of gloves by trained personnel turns out to be a very reliable technique. Additional microbiological tests led to a new concept presented here on how to handle gloves with pinholes and how to take action. With this approach, risks can be minimized and maximum safety maintained by controlling and monitoring the effective bioload on the outside of the gloves.
The Short-term Protective Effects of ‘Non-PPE’ Gloves Used by Greenhouse Workers
Roff, Martin
2015-01-01
Task-based worker exposure assessments are used in regulatory product approval for pesticides. Some agricultural workers may be exposed to pesticide residues predominantly via transfer to the hands during plant tending or crop harvesting. They may use thin ‘splash-resistant single-use’ (SRSU) gloves or cotton gloves as good industry practice, for example, to protect a delicate crop from bruising, rather than specifically for chemical protection. These ‘non-personal protective equipment (PPE)’ gloves may or may not have been tested for chemical resistance, but can nevertheless give limited protection from chemicals. This paper reports experiments to assess the protection factors (PFs) of ‘non-PPE’ gloves against chemicals, to better inform the regulatory exposure assessments. One type of lightweight cotton and three types of 0.1 mm SRSU gloves 25cm long (latex, nitrile, and vinyl) that might be used as ‘non-PPE’ gloves and one type of 0.4 mm PPE nitrile gauntlet 33cm long were worn by 36 volunteers in greenhouses at four nurseries, handling plants sprayed with transferable but non-permeating strontium acetate in four consecutive 1-h sessions, including one session in which no gloves were worn. Dislodgeable foliar residues were measured by rinsing leaves in bags. Each subject carried out their task such as weeding or trimming, for their four sessions on their set of plants. Handwashes followed each session, and the washings were sampled and analysed for strontium. Unprotected hand contamination was taken to be the within-subject ‘challenge’ in the absence of gloves. It ranged from 166 to 4091 µg equivalent of strontium acetate on the hands and increased with increasing foliar residues. Geometric mean PFs were 60 (95% CI 38–87, n = 22) for PPE gauntlets, 32 (25–41, n = 65) for SRSU gloves and 5.3 (3.5–8, n = 21) for lightweight cotton. The PFs offered by the waterproof gloves (gauntlets and SRSU) increased with challenge, but for the absorbent cotton gloves it decreased. The measurement of protection is restricted by the limit of quantification (LOQ) such that protection must apparently increase with challenge, nevertheless the above trends remained even after removal of data
Contact Dermatitis from Penetration of Rubber Gloves by Acrylic Monomer
Pegum, J. S.; Medhurst, F. A.
1971-01-01
An orthopaedic surgeon developed dermatitis from acrylic materials. The acrylic monomer was found to penetrate surgical rubber gloves readily. Cases of “rubber glove dermatitis” with negative patch tests may have a similar explanation. Laboratory tests suggest that monomer does not damage rubber sufficiently to allow bacteria to penetrate gloves, but it remains possible that this would happen under theatre conditions. PMID:5581492
A Glove for Tapping and Discrete 1D/2D Input
NASA Technical Reports Server (NTRS)
Miller, Sam A.; Smith, Andy; Bahram, Sina; SaintAmant, Robert
2012-01-01
This paper describes a glove with which users enter input by tapping fingertips with the thumb or by rubbing the thumb over the palmar surfaces of the middle and index fingers. The glove has been informally tested as the controller for two semi-autonomous robots in a a 3D simulation environment. A preliminary evaluation of the glove s performance is presented.
Glove Testing for Performance Against Flying Glass Shards
2014-09-01
superior dexterity to those with leather palms could still provide protection from flying shards of glass. 15. SUBJECT TERMS PPE...test glove was subject to significant scorching. It was decided that a woven Kevlar® fiber glove with a leather layer, covering both the palm and... leather -palmed gloves were considered too bulky for use by personnel with small hands, greatly decreasing dexterity. The wearer could not
Analysis of Human-Spacesuit Interaction
NASA Technical Reports Server (NTRS)
Thomas, Neha
2015-01-01
Astronauts sustain injuries of various natures such as finger delamination, joint pain, and redness due to their interaction with the space suit. The role of the Anthropometry and Biomechanics Facility is to understand the biomechanics, environmental variables, and ergonomics of the suit. This knowledge is then used to make suggestions for improvement in future iterations of the space suit assembly to prevent injuries while allowing astronauts maneuverability, comfort, and tactility. The projects I was involved in were the Extravehicular Mobility Unit (EMU) space suit stiffness study and the glove feasibility study. The EMU project looked at the forces exerted on the shoulder, arm, and wrist when subjects performed kinematic tasks with and without a pressurized suit. The glove study consisted of testing three conditions - the Series 4000 glove, the Phase VI glove, and the no glove condition. With more than forty channels of sensor data total, it was critical to develop programs that could analyze data with basic descriptive statistics and generate relevant graphs to help understand what happens within the space suit and glove. In my project I created a Graphical User Interface (GUI) in MATLAB that would help me visualize what each sensor was doing within a task. The GUI is capable of displaying overlain plots and can be synchronized with video. This was helpful during the stiffness testing to visualize how the forces on the arm acted while the subject performed tasks such as shoulder adduction/abduction and bicep curls. The main project of focus, however, was the glove comparison study. I wrote MATLAB programs which generated movies of the strain vectors during specific tasks. I also generated graphs that summarized the differences between each glove for the strain, shear and FSR sensors. Preliminary results indicate that the Phase VI glove places less strain and shear on the hand. Future work includes continued data analysis of surveys and sensor data. In the end, the ideal glove is one that provides more tactility for the astronauts but lessens injuries. Often times, a more tactile glove transmits forces better to the hand; thus, achieving a balance of both a tactile and safe glove is the main challenge present.
Detection and toxicity assessment of nitrosamines migration from latex gloves in the Chinese market.
Feng, Di; Wang, Huiping; Cheng, Xuelian; Wang, Jiedong; Ning, Lifeng; Zhou, Qingfeng; Zhou, Yue; Yang, Quanli
2009-09-01
Nitrosamines are potent carcinogens and have been found in latex products. In 2007, twenty-seven natural latex gloves including sterile gloves, examination gloves and household use gloves were sampled from the Chinese market. This study monitored the migration of nitrosamines and nitrosatable substance from these gloves, and evaluated their mutagenicity using a Salmonella typhimurium mutation assay (Ames assay) with the strains TA98, TA97, TA100 and TA102 and by a micronucleus test (MN test) using ICR mice. In addition, the cytotoxicity of these compounds was determined by a MTT assay. N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine (NDEA) and N-nitrosodibutylamine (NDBA) were all found in samples treated with artificial sweat for 4h at 37 degrees C, and total nitrosamines varied from 18.89 to 244.51microg/Kg. The nitrosamine mixture of NDMA, NDEA and NDBA was used in both the Ames assay and the MN test. The proportion of NDMA, NDEA and NDBA (1:10:20) was selected according to the proportion of nitrosamines migration from sample E05. In the Ames assay, the lowest dose (1.98 x 10(-3)microg per plate) produced a positive result in the TA98 strain, corresponding to nitrosamines migration from sample E05 of 0.016g (the total nitrosamines migration from glove E05 was 122.55 microg/kg). The TA100 strain responded positively at a dose of 4.96 x 10(-2)microg per plate, corresponding to nitrosamines migration from glove E05 of 0.040g. The MN test showed nitrosamine migration of 3.04 mg from 2066 pairs of sample E05 and could induce micronuclei in one mouse weighing 28g (average weight of one E05 glove was 6g). Extracts from gloves were found to be cytotoxic and there was a significant correlation between cytotoxicity (IC50) and the release level of nitrosamines. In conclusion, in view of the high content of nitrosamines in latex gloves and the potential toxicity of nitrosamines migration from these gloves, it is suggested that both an effective and feasible detection method and prescribed limits should be imposed.
Phalen, R N; Que Hee, Shane S
2007-02-01
The aim of this study was to investigate the surface variability of 13 powder-free, unlined, and unsupported nitrile rubber gloves using attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectrophotometry at key wavelengths for analysis of captan contamination. The within-glove, within-lot, and between-lot variability was measured at 740, 1124, 1252, and 1735 cm(-1), the characteristic captan reflectance minima wavelengths. Three glove brands were assessed after conditioning overnight at relative humidity (RH) values ranging from 2 +/- 1 to 87 +/- 4% and temperatures ranging from -8.6 +/- 0.7 to 59.2 +/- 0.9 degrees C. For all gloves, 1735 cm(-1) provided the lowest background absorbance and greatest potential sensitivity for captan analysis on the outer glove surface: absorbances ranged from 0.0074 +/- 0.0005 (Microflex) to 0.0195 +/- 0.0024 (SafeSkin); average within-glove coefficients of variation (CV) ranged from 2.7% (Best, range 0.9-5.3%) to 10% (SafeSkin, 1.2-17%); within-glove CVs greater than 10% were for one brand (SafeSkin); within-lot CVs ranged from 2.8% (Best N-Dex) to 28% (SafeSkin Blue); and between-lot variation was statistically significant (p < or = 0.05) for all but two SafeSkin lots. The RH had variable effects dependent on wavelength, being minimal at 1735, 1252, and 1124 cm(-1) and highest at 3430 cm(-1) (O-H stretch region). There was no significant effect of temperature conditioning. Substantial within-glove, within-lot, and between-lot variability was observed. Thus, surface analysis using ATR-FT-IR must treat glove brands and lots as different. ATR-FT-IR proved to be a useful real-time analytical tool for measuring glove variability, detecting surface humidity effects, and choosing selective and sensitive wavelengths for analysis of nonvolatile surface contaminants.
Phalen, Robert N.; Wong, Weng kee
2012-01-01
Background: The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. Objectives: This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. Methods: Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. Results: Significant differences in the leak failure rates and tensile properties existed between the two glove types (P ≤ 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus <4 MPa or area density (AD) <11 g cm−2 were about four times less likely to leak. Conclusions: On average, the low-modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break. PMID:22201179
Phalen, Robert N; Wong, Weng Kee
2012-05-01
The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. Significant differences in the leak failure rates and tensile properties existed between the two glove types (P ≤ 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus <4 MPa or area density (AD) <11 g cm(-2) were about four times less likely to leak. On average, the low-modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break.
Bebbington, M W; Treissman, M J
1996-10-01
Our purpose was to compare the effectiveness of a surgical assist device, SutureMate, to decrease glove perforations during postdelivery vaginal repair. This was a prospective randomized trial. After delivery surgeons who needed to perform vaginal repair were randomized to use the surgical assist device or to perform the repair in the usual fashion. After the repair, gloves were collected and the operator was asked to complete a standardized data form that was submitted with the gloves. The gloves were tested for perforations within 24 hours by the Food and Drug Administration-approved hydrosufflation technique. Comparisons were made with chi(2) statistics with p < 0.01 taken as being statistically significant with the use of a Bonferoni adjustment for multiple comparisons. A total of 476 glove sets were evaluated. The use of the surgical assist device significantly reduced the overall glove perforation rate from 28.3% in the control arm to 8.4% in the study arm (p = 0.0001). Rates of perforation varied with level of training and expertise but fell in all groups that used the device. Family physicians had the highest perforation rate in the control arm and benefited most from the device. A total of 76% of perforations were located in the thumb, index, and second fingers of the nondominant hand. Perforations were recognized in only 16% of the glove sets. The level of satisfaction with the device was mixed, but overall 50% of operators indicated that they were either satisfied or very satisfied with the device. The rate of glove perforation in postdelivery vaginal repair is high. The surgical assist device significantly reduced the rate of glove perforations.
Geens, Tom; Aerts, Evelyne; Borguet, Marc; Haufroid, Vincent; Godderis, Lode
2016-04-01
Many hairdressers leave their profession due to health problems, including occupational hand eczema, which has been associated with skin exposure to sensitising hair dye components such as paraphenylenediamine (PPD) and paratoluenediamine (PTD). Since the use of protective gloves is advised but without the short-term effect being known, our main goal was to attribute a significant biomarker reduction to adequate glove use, in a real work situation. 11 hairdressers were studied over 2 weeks. In the first week, they worked as usual and (re)used their gloves. Thereafter, we intervened to improve glove use during the second week. In both weeks, workplace exposure data were collected through observations, and systemic exposure was quantified by biomonitoring of PPD and PTD. The effect of improved glove use and other exposure determinants was studied through mixed models analysis. We showed that improved glove use significantly reduced mean PTD concentrations from 24.1 before to 4.2 µg/g creatinine after the intervention (n=11, third day postshift). In addition, mean PTD concentrations increased during the first week (14 times elevated after three consecutive shifts), but not during the second week. For PPD, no effect of improved glove use and no accumulation effect were detected. Our study is the first to deliver evidence for a significant reduction in systemic exposure to PTD through improved glove use. Disposable gloves should never be reused. PTD biomonitoring is shown to be a practical tool to quantify recent dermal exposure to oxidative hair dye components. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Casanova, Lisa M; Teal, Lisa J; Sickbert-Bennett, Emily E; Anderson, Deverick J; Sexton, Daniel J; Rutala, William A; Weber, David J
2016-10-01
OBJECTIVE Ebola virus disease (EVD) places healthcare personnel (HCP) at high risk for infection during patient care, and personal protective equipment (PPE) is critical. Protocols for EVD PPE doffing have not been validated for prevention of viral self-contamination. Using surrogate viruses (non-enveloped MS2 and enveloped Φ6), we assessed self-contamination of skin and clothes when trained HCP doffed EVD PPE using a standardized protocol. METHODS A total of 15 HCP donned EVD PPE for this study. Virus was applied to PPE, and a trained monitor guided them through the doffing protocol. Of the 15 participants, 10 used alcohol-based hand rub (ABHR) for glove and hand hygiene and 5 used hypochlorite for glove hygiene and ABHR for hand hygiene. Inner gloves, hands, face, and scrubs were sampled after doffing. RESULTS After doffing, MS2 virus was detected on the inner glove worn on the dominant hand for 8 of 15 participants, on the non-dominant inner glove for 6 of 15 participants, and on scrubs for 2 of 15 participants. All MS2 on inner gloves was observed when ABHR was used for glove hygiene; none was observed when hypochlorite was used. When using hypochlorite for glove hygiene, 1 participant had MS2 on hands, and 1 had MS2 on scrubs. CONCLUSIONS A structured doffing protocol using a trained monitor and ABHR protects against enveloped virus self-contamination. Non-enveloped virus (MS2) contamination was detected on inner gloves, possibly due to higher resistance to ABHR. Doffing protocols protective against all viruses need to incorporate highly effective glove and hand hygiene agents. Infect Control Hosp Epidemiol 2016;1-6.
21 CFR 878.4460 - Surgeon's glove.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Identification. A surgeon's glove is a device made of natural or synthetic rubber intended to be worn by... used in the glove is excluded. (b) Classification. Class I (general controls). [53 FR 23872, June 24...
RoboGlove - A Robonaut Derived Multipurpose Assistive Device
NASA Technical Reports Server (NTRS)
Diftler, Myron; Ihrke, C. A.; Bridgwater, L. B.; Davis, D. R.; Linn, D. M.; Laske, E. A.; Ensley, K. G.; Lee, J. H.
2014-01-01
The RoboGlove is an assistive device that can augment human strength, endurance or provide directed motion for use in rehabilitation. RoboGlove is a spinoff of the highly successful Robonaut 2 (R2) system developed as part of a partnership between General Motors and NASA. This extremely lightweight device employs an actuator system based on the R2 finger drive system to transfer part or the entire grasp load from human tendons to artificial ones contained in the glove. Steady state loads ranging from 15 to 20 lbs. and peaks approaching 50 lbs. are achievable. The technology holds great promise for use with space suit gloves to reduce fatigue during space walks. Tactile sensing, miniaturized electronics, and on-board processing provide sufficient flexibility for applications in many industries. The following describes the design, mechanical/electrical integration, and control features of the glove.
The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation
NASA Technical Reports Server (NTRS)
Reid, Christopher R.; McFarland, Shane M.; Norcross, Jason R.; Rajulu, Sudhakar
2014-01-01
Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis.
The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation
NASA Technical Reports Server (NTRS)
Reid, Christopher R.; McFarland, Shane; Norcross, Jason R.; Rajulu, Sudhakar
2014-01-01
Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis
Makki, D; Deierl, K; Pandit, A; Trakru, S
2014-09-01
The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon's grade, the type of procedure, the role of the assistant and the dominance of the hand. A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1-5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection.
[The risk of surgical glove perforations].
Hagen, Gerd Ødegård; Arntzen, Halvard
2007-03-29
The increasing prevalence of blood-borne viral diseases has drawn attention to the barrier between the surgical personnel's hands and the patients body fluids during surgery. At present, the typical practice is to use double gloving in orthopaedic surgery, and single gloving in other types of surgery. The main purpose of our study was to estimate and compare the perforation risk in different categories of surgery. In a series of 655 surgical operations covering 5 main categories of surgery, all detected glove perforations were recorded and analysed. Perforations were found in 203 out of 655 operations (31%). The observed perforation frequency was 44.5% in gastrointestinal surgery, 34.7% in orthopaedic surgery, 31.1% in gynaecology, 18.6% in vascular surgery and 9.2% in general surgery. In some subcategories, the frequencies were even higher. In several categories of surgery, we found high perforation frequencies. Perforations in single gloves are often not detected during operations. This may increase the risk of transmission of blood-borne infections, particularly because the time of exposure may be long. Double indicator gloves make the intra-operative detection of perforations easier. Also double gloving is known to significantly reduce the perforation risk. The use of double indicator gloves is recommended in all categories of surgery.
Analysis of Asymmetric Aircraft Aerodynamics Due to an Experimental Wing Glove
NASA Technical Reports Server (NTRS)
Hartshorn, Fletcher
2011-01-01
Aerodynamic computational fluid dynamics analysis of a wing glove attached to one wing of a business jet is presented and discussed. A wing glove placed on only one wing will produce asymmetric aerodynamic effects that will result in overall changes in the forces and moments acting on the aircraft. These changes, referred to as deltas, need to be determined and quantified to ensure that the wing glove does not have a significant effect on the aircraft flight characteristics. TRANAIR (Calmar Research Corporation, Cato, New York), a nonlinear full potential solver, and Star-CCM+ (CD-adapco, Melville, New York), a finite volume full Reynolds-averaged Navier-Stokes computational fluid dynamics solver, are used to analyze a full aircraft with and without the glove at a variety of flight conditions, aircraft configurations, and angles of attack and sideslip. Changes in the aircraft lift, drag, and side force along with roll, pitch, and yaw are presented. Span lift and moment distributions are also presented for a more detailed look at the effects of the glove on the aircraft. Aerodynamic flow phenomena due to the addition of the glove are discussed. Results show that the glove produces only small changes in the aerodynamic forces and moments acting on the aircraft, most of which are insignificant.
Chan, K Y; Singh, V A; Oun, B H; To, B H Se
2006-12-01
Glove perforation during surgery has always been a matter of concern as it increases the infection rate and the risk of transmission of blood borne diseases. To determine the common causes, the site and the awareness of glove perforations in orthopaedic surgery, a prospective study was conducted to assess the rate of glove perforation during 130 consecutive orthopaedic operations. All gloves worn by the surgical team were assessed after the surgery using the water-loading test. A total of 1452 gloves were tested, and the rate of perforation was 3.58%. Most of these perforations (61.5%) were unnoticed. The main surgeons had the most perforations (76.9%), followed by first assistants (13.5%) and second assistants (9.6%). Most perforations occurred at the non-dominant hand. The commonest site of perforation was the index finger followed by the thumb. Shearing force with instruments accounted for 45% of the noticed perforations. Majority of these occurred during nailing procedures (33%) and internal fixation without the use of wires (19%). Our rate of glove perforation is similar to other series. Most of them went unnoticed and were mainly due to shearing injuries rather than perforation by sharps. Therefore, there is an increased risk of contamination and break in asepsis during surgery.
Evaluation of surgical glove integrity during surgery in a Brazilian teaching hospital.
de Oliveira, Adriana Cristina; Gama, Camila Sarmento
2014-10-01
A cross-sectional study was conducted in a large university hospital in Belo Horizonte, Minas Gerais, Brazil to evaluate surgical glove integrity after use during surgery. This 6-month study was conducted by a gastroenterological, cardiovascular, and pediatric surgical team consisting of surgeons (main surgeon and first and second assistants), medical students, and scrub nurses. The gloves used during surgery were examined postsurgery for microperforations using the watertight test as described in European Norm EN 455-1. A total of 116 medical professionals conducted the 100 surgeries monitored. Of the 1090 gloves analyzed, 131 (12%) had a perforation detected postsurgery, 39 of which (37.5%) were recognized by users at the time of occurrence. The highest incidence of perforations occurred among surgeons (P = .033) in the index finger, followed by the thumb of the nondominant hand; in outer gloves (76.9%) when double-gloving was used (P = .014); in open surgery (P = .019); and in surgeries lasting ≥ 150 minutes (P < .05). These findings reaffirm the importance of double-gloving, using a perforation indicator system, and changing gloves in surgeries of ≥ 150 minutes duration, especially in procedures involving open incisions. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Vinches, L.; Peyrot, C.; Lemarchand, L.; Boutrigue, N.; Zemzem, M.; Wilkinson, K. J.; Hallé, S.; Tufenkji, N.
2015-05-01
Parallel to the increased use of engineered nanoparticles (ENP) in the formulation of commercial products or in medicine, numerous health & safety agencies have recommended the application of the precautionary principle to handle ENP; namely, the recommendation to use protective gloves against chemicals. However, recent studies reveal the penetration of titanium dioxide nanoparticles through nitrile rubber protective gloves in conditions simulating occupational use. This project is designed to understand the links between the penetration of gold nanoparticles (nAu) through nitrile rubber protective gloves and the mechanical and physical behaviour of the elastomer material subjected to conditions simulating occupational use (i.e., mechanical deformations (MD) and sweat). Preliminary analyses show that nAu suspensions penetrate selected glove materials after exposure to prolonged (3 hours) dynamic deformations. Significant morphological changes are observed on the outer surface of the glove sample; namely, the number and the surface of the micropores on the surface increase. Moreover, nitrile rubber protective gloves are also shown to be sensitive to the action of nAu suspension and to the action of the saline solution used to simulate sweat (swelling).
The effects of different materials of protective gloves on thermoregulatory responses.
Hayashi, C; Tokura, H
1999-01-01
The effects of two kinds of protecting gloves for pesticide spraying made of different materials on thermoregulatory responses during exercise were studied at ambient temperature of 28 degrees C and relative humidity of 60% in six healthy females, aged 19. One kind of gloves was made of polyurethane (A) and the other of Goretex (B) with cotton lining in each glove. Both kinds of gloves had almost the same volume. Main results of the experiment were summarised as follows: (1) during the exercise an increase of rectal temperature was inhibited more effectively in B than in A; (2) skin temperature of hand was significantly lower in B than in A; (3) absolute humidity and temperature inside the gloves were significantly lower during the period from the gripping bar exercise to the end of the experiment; (4) the number of contractions by the handgrip exercise performed immediately after the second turning of the screw was significantly smaller in A than in B. The findings presented suggest that the gloves made of Goretex material could reduce thermal strain during intermittent work in warm environmental conditions.
2008-09-01
of magnetic UXO. The prototype STAR Sensor comprises: a) A cubic array of eight fluxgate magnetometers . b) A 24-channel data acquisition/signal...array (shaded boxes) of eight low noise Triaxial Fluxgate Magnetometers (TFM) develops 24 channels of vector B- field data. Processor hardware
Development of a Flexible Seal for a 60 psi Cryogenic Pressure Box
NASA Technical Reports Server (NTRS)
Glass, David E.
1998-01-01
A cryogenic pressure box test facility has been designed and fabricated for use at NASA Langley Research Center (LaRC) to subject 5 ft x 6 ft curved panels to cryogenic temperatures and biaxial tensile loads. The cryogenic pressure box is capable of testing curved panels down to -423 F (20 K) with 54 psig maximum pressure. The key challenge in the design and fabrication of the pressure box was the development of a seal that could remain flexible at -423 F and contain 60 psi gaseous helium as the pressurization gas. A C-shaped seal was developed using a Gore-tex woven fabric. Mechanical testing of the fabric at room and elevated temperature, liquid nitrogen temperature, and liquid helium temperature demonstrated the strength and creep resistance of the material over the desired operating range. A small scale cryogenic pressure box was used to test prototype seals at cryogenic temperatures up to 60 psi. Preliminary tests indicated that excessive leakage was present through the seal. As a result, an aluminized mylar liner was placed inside the Gore-tex seal to reduce leakage through the seal. The final seal configuration resulted in minimal pressure loss during seal testing.
CHARACTERIZATION OF GLOVEBOX GLOVES FOR THE SAVANNAH RIVER SITE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korinko, P.
A task was undertaken to characterize glovebox gloves that are currently used in the facilities at Savannah River Site (SRS) as well as some experimental and advanced compound gloves that have been proposed for use. Gloves from four manufacturers were tested for permeation in hydrogen and air, thermal stability, tensile properties, puncture resistance and dynamic mechanical response. The gloves were compared to each other within the type and also to the butyl rubber glove that is widely used at the SRS. The permeation testing demonstrated that the butyl compounds from three of the vendors behaved similarly and exhibited hydrogen permeabilitiesmore » of .52‐.84 x10{sup ‐7} cc H{sub 2}*cm / (cm{sup 2}*atm). The Viton glove performed at the lower edge of this bound, while the more advanced composite gloves exhibited permeabilities greater than a factor of two compared to butyl. Thermogravimetric analysis was used to determine the amount of material lost under slightly aggressive conditions. Glove losses are important since they can affect the life of glovebox stripper systems. During testing at 90, 120, and 150°C, the samples lost most of the mass in the initial 60 minutes of thermal exposure and as expected increasing the temperature increased the mass loss and shortened the time to achieve a steady state loss. The ranking from worst to best was Jung butyl‐Hypalon with 12.9 %, Piercan Hypalon with 11.4 %, and Jung butyl‐Viton with 5.2% mass loss all at approximately 140°C. The smallest mass losses were experienced by the Jung Viton and the Piercan polyurethane. Tensile properties were measured using a standard dog bone style test. The butyl rubber exhibited tensile strengths of 11‐15 MPa and elongations or 660‐843%. Gloves made from other compounds exhibited lower tensile strengths (5 MPa Viton) to much higher tensile strengths (49 MPa Urethane) with a comparable range of elongation. The puncture resistance of the gloves was measured in agreement with an ASTM standard. The Butyl gloves exhibited puncture resistance from 183 - 296 lbs/in for samples of 0.020 - 0.038 thick. Finally, the glass transition temperature and the elastic and viscoelastic properties as a function of temperature up to maximum use temperature were determined for each glove material using Dynamic Mechanical Analysis. The glass transition temperatures of the gloves were ‐60°C for butyl, ‐30°C for polyurethane, ‐ 16°C Hypalon, ‐16°C for Viton, and ‐24°C for polyurethane‐Hypalon. The glass transition was too complex for the butyl‐Hypalon and butyl‐Viton composite gloves to be characterized by a single glass transition temperature. All of the glass transition temperatures exceed the vendor projected use temperatures.« less
Gloved Human-Machine Interface
NASA Technical Reports Server (NTRS)
Adams, Richard (Inventor); Hannaford, Blake (Inventor); Olowin, Aaron (Inventor)
2015-01-01
Certain exemplary embodiments can provide a system, machine, device, manufacture, circuit, composition of matter, and/or user interface adapted for and/or resulting from, and/or a method and/or machine-readable medium comprising machine-implementable instructions for, activities that can comprise and/or relate to: tracking movement of a gloved hand of a human; interpreting a gloved finger movement of the human; and/or in response to interpreting the gloved finger movement, providing feedback to the human.
Deierl, K; Pandit, A; Trakru, S
2014-01-01
Introduction The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. Methods During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon’s grade, the type of procedure, the role of the assistant and the dominance of the hand. Results A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1–5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Conclusions Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection. PMID:25198974
Vandenplas, O; Larbanois, A; Vanassche, F; François, S; Jamart, J; Vandeweerdt, M; Thimpont, J
2009-03-01
Natural rubber latex (NRL) has become as a major cause of occupational asthma (OA) in workers using NRL gloves. Few population-based studies have assessed the impact of changes in the patterns of glove usage on the incidence of NRL-induced OA. To characterize the time trends in incident cases of NRL-induced OA in Belgium and examine whether incidence rates were related to the types of gloves used in hospitals. Incident cases of NRL-induced OA were identified through a retrospective review of all claims submitted to the Workers' Compensation Board up to December 2004. Based on the results of diagnostic procedures, the diagnosis of NRL-induced OA was categorized as definite, probable, unlikely, or indeterminate. The patterns of glove usage were characterized through a questionnaire survey of Belgian hospitals. A total of 298 claims for NRL-induced OA were identified, including 127 subjects with definite OA and 68 with probable OA. Categorized by the year of asthma onset, the incident cases of definite and probable NRL-induced OA markedly decreased from 1999 onwards. The use of powdered NRL gloves fell from 80.9% in 1989 to 17.9% in 2004. Powdered NRL gloves were predominantly substituted with NRL-free gloves, especially in the case of non-sterile procedures. These national compensation-based data confirm that a persistent decline in the incidence of NRL-induced OA has occurred since late 1990s. This downward trend has temporally been associated with a decreasing usage of powdered NRL, further supporting a beneficial role of changes in glove policies.
NASA Technical Reports Server (NTRS)
Kilby, Melissa
2015-01-01
Functional Extravehicular Mobility Units (EMUs) with high precision gloves are essential for the success of Extravehicular Activity (EVA). Previous research done at NASA has shown that total strength capabilities and performance are reduced when wearing a pressurized EMU. The goal of this project was to characterize the human-space suit glove interaction and assess the risk of injury during common EVA hand manipulation tasks, including pushing, pinching and gripping objects. A custom third generation sensor garment was designed to incorporate a combination of sensors, including force sensitive resistors, strain gauge sensors, and shear force sensors. The combination of sensors was used to measure the forces acting on the finger nails, finger pads, finger tips, as well as the knuckle joints. In addition to measuring the forces, data was collected on the temperature, humidity, skin conductance, and blood perfusion of the hands. Testing compared both the Phase VI and Series 4000 glove against an ungloved condition. The ungloved test was performed wearing the sensor garment only. The project outcomes identified critical landmarks that experienced higher workloads and are more likely to suffer injuries. These critical landmarks varied as a function of space suit glove and task performed. The results showed that less forces were acting on the hands while wearing the Phase VI glove as compared to wearing the Series 4000 glove. Based on our findings, the engineering division can utilize these methods for optimizing the current space suit glove and designing next generation gloves to prevent injuries and optimize hand mobility and comfort.
An Approach for Performance Based Glove Mobility Requirements
NASA Technical Reports Server (NTRS)
Aitchison, Lindsay; Benson, Elizabeth; England, Scott
2016-01-01
The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for exploration missions. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Space Technology Mission Directorate's Game-Changing Development Program provided start-up funding for the High Performance EVA Glove (HPEG) Element as part of the Next Generation Life Support (NGLS) Project in the fall of 2013. The overarching goal of the HPEG Element is to develop a robust glove design that increases human performance during EVA and creates pathway for implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability in on-pristine environments, and decreasing the potential of gloves to cause injury during use. The HPEG Element focused initial efforts on developing quantifiable and repeatable methodologies for assessing glove performance with respect to mobility, injury potential, thermal conductivity, and abrasion resistance. The team used these methodologies to establish requirements against which emerging technologies and glove designs can be assessed at both the component and assembly levels. The mobility performance testing methodology was an early focus for the HPEG team as it stems from collaborations between the SSA Development team and the JSC Anthropometry and Biomechanics Facility (ABF) that began investigating new methods for suited mobility and fit early in the Constellation Program. The combined HPEG and ABF team used lessons learned from the previous efforts as well as additional reviews of methodologies in physical and occupational therapy arenas to develop a protocol that assesses gloved range of motion, strength, dexterity, tactility, and fit in comparative quantitative terms and also provides qualitative insight to direct hardware design iterations. The protocol was evaluated using five experienced test subjects wearing the EMU pressurized to 4.3psid with three different glove configurations. The results of the testing are presented to illustrate where the protocol is and is not valid for benchmark comparisons. The process for requirements development based upon the results is also presented along with suggested performance values for the High Performance EVA Gloves currently in development.
An Approach for Performance Based Glove Mobility Requirements
NASA Technical Reports Server (NTRS)
Aitchison, Lindsay; Benson, Elizabeth; England, Scott
2015-01-01
The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for exploration missions. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Space Technology Mission Directorate's Game-Changing Development Program provided start-up funding for the High Performance EVA Glove (HPEG) Element as part of the Next Generation Life Support (NGLS) Project in the fall of 2013. The overarching goal of the HPEG Element is to develop a robust glove design that increases human performance during EVA and creates pathway for implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability in on-pristine environments, and decreasing the potential of gloves to cause injury during use. The HPEG Element focused initial efforts on developing quantifiable and repeatable methodologies for assessing glove performance with respect to mobility, injury potential, thermal conductivity, and abrasion resistance. The team used these methodologies to establish requirements against which emerging technologies and glove designs can be assessed at both the component and assembly levels. The mobility performance testing methodology was an early focus for the HPEG team as it stems from collaborations between the SSA Development team and the JSC Anthropometry and Biomechanics Facility (ABF) that began investigating new methods for suited mobility and fit early in the Constellation Program. The combined HPEG and ABF team used lessons learned from the previous efforts as well as additional reviews of methodologies in physical and occupational therapy arenas to develop a protocol that assesses gloved range of motion, strength, dexterity, tactility, and fit in comparative quantitative terms and also provides qualitative insight to direct hardware design iterations. The protocol was evaluated using five experienced test subjects wearing the EMU pressurized to 4.3psid with three different glove configurations. The results of the testing are presented to illustrate where the protocol is and is not valid for benchmark comparisons. The process for requirements development based upon the results is also presented along with suggested performance values for the High Performance EVA Gloves to be procured in fiscal year 2015.
Mapping From an Instrumented Glove to a Robot Hand
NASA Technical Reports Server (NTRS)
Goza, Michael
2005-01-01
An algorithm has been developed to solve the problem of mapping from (1) a glove instrumented with joint-angle sensors to (2) an anthropomorphic robot hand. Such a mapping is needed to generate control signals to make the robot hand mimic the configuration of the hand of a human attempting to control the robot. The mapping problem is complicated by uncertainties in sensor locations caused by variations in sizes and shapes of hands and variations in the fit of the glove. The present mapping algorithm is robust in the face of these uncertainties, largely because it includes a calibration sub-algorithm that inherently adapts the mapping to the specific hand and glove, without need for measuring the hand and without regard for goodness of fit. The algorithm utilizes a forward-kinematics model of the glove derived from documentation provided by the manufacturer of the glove. In this case, forward-kinematics model signifies a mathematical model of the glove fingertip positions as functions of the sensor readings. More specifically, given the sensor readings, the forward-kinematics model calculates the glove fingertip positions in a Cartesian reference frame nominally attached to the palm. The algorithm also utilizes an inverse-kinematics model of the robot hand. In this case, inverse-kinematics model signifies a mathematical model of the robot finger-joint angles as functions of the robot fingertip positions. Again, more specifically, the inverse-kinematics model calculates the finger-joint commands needed to place the fingertips at specified positions in a Cartesian reference frame that is attached to the palm of the robot hand and that nominally corresponds to the Cartesian reference frame attached to the palm of the glove. Initially, because of the aforementioned uncertainties, the glove fingertip positions calculated by the forwardkinematics model in the glove Cartesian reference frame cannot be expected to match the robot fingertip positions in the robot-hand Cartesian reference frame. A calibration must be performed to make the glove and robot-hand fingertip positions correspond more precisely. The calibration procedure involves a few simple hand poses designed to provide well-defined fingertip positions. One of the poses is a fist. In each of the other poses, a finger touches the thumb. The calibration subalgorithm uses the sensor readings from these poses to modify the kinematical models to make the two sets of fingertip positions agree more closely.
Holme, Jørgen Bendix; Mortensen, Frank Viborg
2005-08-01
To test the use of a simple and cheap powder-free glove bag to extract the gallbladder during laparoscopic cholecystectomy (LC). The medical records of 142 consecutive patients who had their gallbladder removed using a powder-free glove bag were reviewed. No complications in the form of bile or stone spillage during extraction were observed. The absence of complications and the low cost make routine use of the glove bag a wise option for extracting the gallbladder during LC. The use of the glove bag seems to reduce the risk of contamination with bacteria, bile, and gallstones and may reduce contamination by malignant cells in case of unexpected gallbladder carcinoma.
Design of an Inertial-Sensor-Based Data Glove for Hand Function Evaluation.
Lin, Bor-Shing; Lee, I-Jung; Yang, Shu-Yu; Lo, Yi-Chiang; Lee, Junghsi; Chen, Jean-Lon
2018-05-13
Capturing hand motions for hand function evaluations is essential in the medical field. Various data gloves have been developed for rehabilitation and manual dexterity assessments. This study proposed a modular data glove with 9-axis inertial measurement units (IMUs) to obtain static and dynamic parameters during hand function evaluation. A sensor fusion algorithm is used to calculate the range of motion of joints. The data glove is designed to have low cost, easy wearability, and high reliability. Owing to the modular design, the IMU board is independent and extensible and can be used with various microcontrollers to realize more medical applications. This design greatly enhances the stability and maintainability of the glove.
Evaluation of the flexibility of protective gloves.
Harrabi, Lotfi; Dolez, Patricia I; Vu-Khanh, Toan; Lara, Jaime
2008-01-01
Two mechanical methods have been developed for the characterization of the flexibility of protective gloves, a key factor affecting their degree of usefulness for workers. The principle of the first method is similar to the ASTM D 4032 standard relative to fabric stiffness and simulates the deformations encountered by gloves that are not tight fitted to the hand. The second method characterizes the flexibility of gloves that are worn tight fitted. Its validity was theoretically verified for elastomer materials. Both methods should prove themselves as valuable tools for protective glove manufacturers, allowing for the characterization of their existing products in terms of flexibility and the development of new ones better fitting workers' needs.
Natural rubber latex allergy after 12 years: recommendations and perspectives.
Charous, B Lauren; Blanco, Carlos; Tarlo, Susan; Hamilton, Robert G; Baur, Xaver; Beezhold, Donald; Sussman, Gordon; Yunginger, John W
2002-01-01
Natural rubber latex (NRL) allergy is a "new" illness whose prevalence reached epidemic proportions in highly exposed populations during the last decade. In children with spina bifida and in patients exposed to NRL during radiologic procedures, institution of prophylactic safety measures has had demonstrable effects in preventing allergic reactions. The risk of NRL allergy appears to be largely linked to occupational exposure, and NRL-associated occupational asthma is due almost solely to powdered latex glove use. Prevalence of NRL-allergic sensitization in the general population is quite low; several studies of young adults demonstrate rates of positive skin test results that are less than 1%. After occupational exposure, rates of sensitization and NRL-induced asthma rise dramatically in individuals using powdered NRL gloves but not in individuals using powder-free gloves. Airborne NRL is dependent on the use of powdered NRL gloves; conversion to non-NRL or nonpowdered NRL substitutes results in predictable rapid disappearance of detectable levels of aeroallergen. For these reasons, adoption of the following institutional policies designed to prevent new cases of NRL allergy and maximize safety is recommended: (1) NRL gloves should be used only as mandated by accepted Standard Precautions; (2) only nonpowdered, nonsterile NRL gloves should be used; and (3) nonpowdered, sterile NRL gloves are preferred for use. Low-protein powdered, sterile gloves may be used, but only in conjunction with an ongoing assessment for development of allergic reactions.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-17
... quality levels (AQLs) for leaks and visual defects observed during FDA testing of medical gloves. The CPG... practices regulation (21 CFR 10.115). The CPG represents FDA's current thinking on the criteria for direct...
A Case of Chromium Contact Dermatitis due to Exposure from a Golf Glove.
Lim, Jong Ho; Kim, Hei Sung; Park, Young Min; Lee, Jun Young; Kim, Hyung Ok
2010-02-01
Chromium is a transition metal and has been shown to elicit contact dermatitis. Although leather products have been known to be the most significant source of chromium exposure these days, the majority of reports have been related to exposure from shoe products. We herein report a professional golfer who became allergic to golf gloves made of chromium-tanned leather. A 27-year-old woman golfer presented with recurrent, pruritic, erythematous plaques that had been occurring on both hands for several years. The lesions developed whenever she had worn golf gloves for an extended period of time, especially during tournament season. To identify the causative agent, patch tests were performed and the results demonstrated a strong positive reaction to potassium dichromate 0.5% and to her own glove. The amount of chromium in her golf glove was analyzed to be 308.91 ppm and based on this, a diagnosis of allergic contact dermatitis due to a chromium-tanned leather glove was made. She was treated with oral antihistamines combined with topical steroids and advised to wear chromium-free leather gloves. There has been no evidence of recurrence during a six month follow-up period.
Retained portion of latex glove during femoral nailing. Case report.
Sadat-Ali, M; Marwah, S; al-Habdan, I
1996-11-01
A case of retained glove during Kuntscher intramedullary nailing is described. An abscess around the glove could have lead to osteomyelitis. One need to be cautious feeling the top end of the nail while femoral nailing to avoid such a complication.
Van Wicklin, Sharon A
2016-05-01
Variations in documenting surgical wound classification Key words: surgical wound classification, clean, clean-contaminated, contaminated, dirty. Wearing long-sleeved jackets while preparing and packaging items for sterilization Key words: long-sleeved jackets, organic material, sterile processing. Endoscopic transmission of prions Key words: prions, high-risk tissue, low-risk tissue, Creutzfeldt-Jakob disease (CJD), variant Creutzfeldt-Jakob disease (vCJD). Wearing gloves when handling flexible endoscopes Key words: gloves, low-protein, powder-free, natural rubber latex gloves, latex-free gloves. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Development of Wireless RFID Glove for Various Applications
NASA Astrophysics Data System (ADS)
Lee, Changwon; Kim, Minchul; Park, Jinwoo; Oh, Jeonghoon; Eom, Kihwan
Radio Frequency Identification is increasingly popular technology with many applications. The majority of applications of RFID are supply-chain management. In this paper, we proposed the development of wireless RFID Glove for various applications in real life. Proposed wireless RFID glove is composed of RFID reader of 13.56 MHz and RF wireless module. Proposed Gloves were applied to two applications. First is the interactive leaning and second is Meal aid system for blind people. The experimental results confirmed good performances.
A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector
NASA Astrophysics Data System (ADS)
Banks, T. I.; Freedman, S. J.; Wallig, J.; Ybarrolaza, N.; Gando, A.; Gando, Y.; Ikeda, H.; Inoue, K.; Kishimoto, Y.; Koga, M.; Mitsui, T.; Nakamura, K.; Shimizu, I.; Shirai, J.; Suzuki, A.; Takemoto, Y.; Tamae, K.; Ueshima, K.; Watanabe, H.; Xu, B. D.; Yoshida, H.; Yoshida, S.; Kozlov, A.; Grant, C.; Keefer, G.; Piepke, A.; Bloxham, T.; Fujikawa, B. K.; Han, K.; Ichimura, K.; Murayama, H.; O`Donnell, T.; Steiner, H. M.; Winslow, L. A.; Dwyer, D. A.; McKeown, R. D.; Zhang, C.; Berger, B. E.; Lane, C. E.; Maricic, J.; Miletic, T.; Batygov, M.; Learned, J. G.; Matsuno, S.; Sakai, M.; Horton-Smith, G. A.; Downum, K. E.; Gratta, G.; Efremenko, Y.; Perevozchikov, O.; Karwowski, H. J.; Markoff, D. M.; Tornow, W.; Heeger, K. M.; Detwiler, J. A.; Enomoto, S.; Decowski, M. P.
2015-01-01
We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. An infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable's motion, and the system was controlled via a graphical user interface.
Transoral tracheal intubation of rodents using a fiberoptic laryngoscope.
Costa, D L; Lehmann, J R; Harold, W M; Drew, R T
1986-06-01
A fiberoptic laryngoscope which allows direct visualization of the deep pharynx and epiglottis has been developed for transoral tracheal intubation of small laboratory mammals. The device has been employed in the intubation and instillation of a variety of substances into the lungs of rats, and with minor modification, has had similar application in mice, hamsters, and guinea pigs. The simplicity and ease of handling of the laryngoscope permits one person to intubate large numbers of enflurane anesthetized animals either on an open counter top or in a glove-box, as may be required for administration of carcinogenic materials. Instillation of 7Be-labeled carbon particles into the lungs of mice, hamsters, rats, and guinea pigs resulted in reasonably consistent interlobal distribution of particles for each test animal species with minimal tracheal deposition. However, actual lung tissue doses of carbon exhibited some species dependence.
ASTROCULTURE(tm) Commercial Plant Growth Unit and Glove Box Insert
NASA Technical Reports Server (NTRS)
Zhou, Wei-Jia; Lambing, Steve (Technical Monitor)
2002-01-01
Two commercial plant investigations will be conducted during the STS-107 mission: living flower essential oil production and gene transfer. The research will be done using the ASTROCULTURE (trademark) hardware, which builds on similar experiments flown in the past on the space shuttle. This research will investigate how microgravity might affect the formation of the volatile chemical compounds - the essential oils - produced by two different types of living flowers. The flowers will be cultured in the ASTROCULTURE (trademark) plant chamber, which provides an enclosed and controlled environment. As the flowers bloom in space, they will produce essential oils, and these volatile compounds will be collected using International Flavors and Fragrance's proprietary Solid Phase Micro Extraction (SPME) technology. The gene transfer experiment examines a newly developed transformation system to see if it operates efficiently in the microgravity environment. This research is important for the development of genetically engineered crops, also known as transgenic crops.
Full length view of the Spacelab module
2016-08-12
STS083-312-031 (4-8 April 1997) --- Payload specialist Gregory T. Linteris (left) is seen at the Mid Deck Glove Box (MGBX), while astronaut Donald A. Thomas, mission specialist, works at the Expedite the Processing of Experiments to Space Station (EXPRESS) rack. MGBX is a facility that allows scientists the capability of doing tests on hardware and materials that are not approved to be handled in the open Spacelab. It is equipped with photographic, video and data recording capability, allowing a complete record of experiment operations. Experiments performed on STS-83 were Bubble Drop Nonlinear Dynamics and Fiber Supported Droplet Combustion. EXPRESS is designed to provide accommodations for Sub-rack payloads on Space Station. For STS-83, it held two payloads. The Physics of Hard Colloidal Spheres (PHaSE) and ASTRO-Plant Generic Bioprocessing Apparatus (ASTRO-PGBA), a facility with light and atmospheric controls which supports plant growth for commercial research.
A preliminary investigation into the effect of pressure on flotation performance
NASA Astrophysics Data System (ADS)
Young, Courtney A.
2007-10-01
In a previous study, various pyrite depressants were examined to improve the flotation performance of a copper-sulfide ore containing tetrahedrite (Cu12Sb4S13). Optimal results from this study were used to examine the effect of elevation on recovery and grade. Tests were conducted at elevations of 3,350 meters, 1,735 meters, 610 meters, and-760 meters, consisting of five repetitive experiments for statistical analysis. The experiments were performed both with and without airflow control. Tests were also performed in a glove box at Montana Tech of The University of Montana to mimic the pressure conditions. Results indicate that both recovery and grade are dependent on pressure via bubble size and airflow, suggesting that pressurized fl otation cells should be considered for operations, particularly those at high elevation. Economics are extremely favorable for implementation because ensuing capital expenses are inconsequential with minimal time for return-on-investment.
Facilities for Biological Research Aboard the International Space Station
NASA Technical Reports Server (NTRS)
Souza, Kenneth A.; Yost, Bruce D.; Berry, William E.; Johnson, Catherine C.
1996-01-01
A centrifuge designed as part of an integrated biological facility for installation onboard the International Space Station is presented. The requirements for the 2.5 m diameter centrifuge, which is designed for the support of biological experiments are discussed. The scientific objectives of the facility are to: provide a means of conducting fundamental studies in which gravitational acceleration is a controllable variable; provide a 1g control; determine the threshold acceleration for physiological response, and determine the value of centrifugation as a potential countermeasure for the biomedical problems associated with space flight. The implementation of the facility is reported on, and the following aspects of the facility are described: the host resources systems supply requirements such as power and data control; the habitat holding rack; the life sciences glove box; the centrifuge; the different habitats for cell culture, aquatic studies, plant research and insect research; the egg incubator, and the laboratory support equipment.
Return to Flight Resource Reel 1 of 2
NASA Technical Reports Server (NTRS)
2005-01-01
A video presentation detailing the tests performed on the Space Shuttle Discovery in preparation for its return to flight is shown. The tests include: 1) Reinforced Carbon-Carbon (RCC) Impact Test Article; 2) RCC Foam Impact Testing; 3) Thermal Protection System (TPS) Ice Impact Testing featuring Justin Kerr, Project Engineer; 4) Wing Leading Edge Wireless Sensors featuring Karl Kiefer, President and CEO of Invocon, and Kevin Champaigne of Invocon; 5) TPS Repair Testing KC-135 Zero-G Environment featuring Soichi Noguchi, Mission Specialist; 6) TPS Extravehicular Activity Tool Demonstration; 7) TPS Repair Testing Vacuum Glove box; 8) TPS Repair Testing Human Thermal Vacuum Chamber; 9) TPS Reentry Testing Atmospheric Reentry Materials and Structures Evaluation Facility; 10) TPS Alternative Repair Concept; 11) Lora Bailey Lead Engineer for EVA Tools; 12) Reinforced Carbon-Carbon ATK Thiokol Plug Repair Animation; 13) 3-Percent Model Build-Up; and 14) Wind Tunnel Testing RCC Aging Research Ballistic Testing.
NASA Technical Reports Server (NTRS)
Fotedar, L. K.; Marshburn, T.; Quast, M. J.; Feeback, D. L.
1999-01-01
Forearm muscle fatigue is one of the major limiting factors affecting endurance during performance of deep-space extravehicular activity (EVA) by crew members. Magnetic resonance (MR) provides in vivo noninvasive analysis of tissue level metabolism and fluid exchange dynamics in exercised forearm muscles through the monitoring of proton magnetic resonance imaging (MRI) and phosphorus magnetic resonance spectroscopy (P-31-MRS) parameter variations. Using a space glove box and EVA simulation protocols, we conducted a preliminary MRS/MRI study in a small group of human test subjects during submaximal exercise and recovery and following exhaustive exercise. In assessing simulated EVA-related muscle fatigue and function, this pilot study revealed substantial changes in the MR image longitudinal relaxation times (T2) as an indicator of specific muscle activation and proton flux as well as changes in spectral phosphocreatine-to-phosphate (PCr/Pi) levels as a function of tissue bioenergetic potential.
A simple, broad-scope nickel(0) precatalyst system for direct amination of allyl alcohols.
Sweeney, Joseph B; Ball, Anthony; Lawrence, Philippa; Sinclair, Mackenzie; Smith, Luke
2018-06-25
The preparation of allylic amines is traditionally accomplished by reaction of amines with reactive electrophiles, such as allylic halides, sulfonates or oxyphosphonium species; such methods involve hazardous reagents, generate stoichiometric waste streams, and often suffer from side-reactions (such as over-alkylation). We report here the first nickel-catalysed direct amination of allyl alcohols which enables allylation of primary, secondary and electron-deficient amines, using an inexpensive Ni(II)-Zn couple, without need for glove-box techniques. Under mild conditions, primary and secondary aliphatic amines react smoothly with a range of allyl alcohols, giving secondary and tertiary amines efficiently. This 'totally catalytic' method can be also applied to electron-deficient nitrogen nucleophiles with effective results; the practicality of the process has been demonstrated in an efficient, gram-scale preparation of the calcium antagonist drug substance flunarizine (Sibelium®). © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Investigation on edge joints of Inconel 625 sheets processed with laser welding
NASA Astrophysics Data System (ADS)
Caiazzo, F.; Alfieri, V.; Cardaropoli, F.; Sergi, V.
2017-08-01
Laser welding of Inconel 625 edge joint beads in square groove configuration was investigated. The use of different weld geometries in new aerospace solutions explains research on edge joints. A structured plan was carried out in order to characterize the process defining the influence of laser power and welding speed and to study possible interactions among the governing factors. As weld pool protection is crucial in order to obtain sound joints when processing superalloys, a special glove box for gas supply was designed to upgrade the welding head. Welded joints were characterized referring to bead profile, microstructure and X-rays. It was found that heat input plays an important role as it affects welding stability, porosity content and bead shape. Results suggest operating with low values of heat input to reduce porosity and guarantee stable bead conformation. Furthermore, a decrease in the grain size has been observed as a consequence of decreasing heat input.
Design and fabrication of 55-gallon drum shuffler standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, S.M.; Hsue, F.; Hoth, C.
1994-08-01
To analyze waste with varying levels of nuclear material, suitable standards are needed to calibrate analytical instrumentation. At the Los Alamos Plutonium Facility, the authors have designed and fabricated a single drum standard for a passive-active neutron counter (shuffler). The standard is modified simply by adding or subtracting plutonium of uranium cylinders to adapt to a range of nuclear material. The plutonium or uranium oxide was placed into small cylindrical containers (1-in. diameter by 5-in. long) and diluted with diatomaceous earth. The cylinders were welded closed and removed from the glove box environment without any external contamination. The containers weremore » leak tested and then placed on a segmented gamma scanner to assure homogeneous distribution of the nuclear material. The cylinders are now placed into the drum to achieve the needed ranges for calibration of the instruments.« less
NASA Technical Reports Server (NTRS)
Yacobucci, H. G.; Heestand, R. L.; Kizer, D. E.
1973-01-01
The techniques used to fabricate cermet bearings for the fueled control drums of a liquid metal cooled reference-design reactor concept are presented. The bearings were designed for operation in lithium for as long as 5 years at temperatures to 1205 C. Two sets of bearings were fabricated from a hafnium carbide - 8-wt. % molybdenum - 2-wt. % niobium carbide cermet, and two sets were fabricated from a hafnium nitride - 10-wt. % tungsten cermet. Procedures were developed for synthesizing the material in high purity inert-atmosphere glove boxes to minimize oxygen content in order to enhance corrosion resistance. Techniques were developed for pressing cylindrical billets to conserve materials and to reduce machining requirements. Finishing was accomplished by a combination of diamond grinding, electrodischarge machining, and diamond lapping. Samples were characterized in respect to composition, impurity level, lattice parameter, microstructure and density.
Aho, E.; Mikkelä, A.; Ranta, J.; Tuominen, P.; Rättö, M.; Maunula, L.
2014-01-01
Human noroviruses (HuNoVs), a leading cause of food-borne gastroenteritis worldwide, are easily transferred via ready-to-eat (RTE) foods, often prepared by infected food handlers. In this study, the transmission of HuNoV and murine norovirus (MuNoV) from virus-contaminated hands to latex gloves during gloving, as well as from virus-contaminated donor surfaces to recipient surfaces after simulated preparation of cucumber sandwiches, was inspected. Virus transfer was investigated by swabbing with polyester swabs, followed by nucleic acid extraction from the swabs with a commercial kit and quantitative reverse transcription-PCR. During gloving, transfer of MuNoV dried on the hand was observed 10/12 times. HuNoV, dried on latex gloves, was disseminated to clean pairs of gloves 10/12 times, whereas HuNoV without drying was disseminated 11/12 times. In the sandwich-preparing simulation, both viruses were transferred repeatedly to the first recipient surface (left hand, cucumber, and knife) during the preparation. Both MuNoV and HuNoV were transferred more efficiently from latex gloves to cucumbers (1.2% ± 0.6% and 1.5% ± 1.9%) than vice versa (0.7% ± 0.5% and 0.5% ± 0.4%). We estimated that transfer of at least one infective HuNoV from contaminated hands to the sandwich prepared was likely to occur if the hands of the food handler contained 3 log10 or more HuNoVs before gloving. Virus-contaminated gloves were estimated to transfer HuNoV to the food servings more efficiently than a single contaminated cucumber during handling. Our results indicate that virus-free food ingredients and good hand hygiene are needed to prevent HuNoV contamination of RTE foods. PMID:24951789
Duteille, Franck; Jeffery, Steven L A
2012-11-01
Nylon-reinforced silver sodium carboxymethylcellulose (AQUACEL(®) Ag BURN) dressings were developed to be pliable and conforming for the management of partial-thickness burns. This study evaluated the AQUACEL(®) Ag BURN glove for the management of hand burns. This 21-day, phase II, prospective, non-comparative study included 23 patients with partial-thickness hand burn of at least two fingers. The AQUACEL(®) Ag BURN glove was applied to one hand and could remain in place up to 21 days until clinically indicated to change the glove. Dressings were evaluated 1, 2, 4, 6, 8, 14, and 21 days after initial application. Safety was the primary study endpoint. Sixteen (70%) hand burns re-epithelialized fully over a mean of 15.6 days. Initial application was easy/very easy for 20 (87%) patients. Mean time for initial dressing application was 5.4 min. At final evaluation, most patients gave ratings of excellent/good for conformability (91%), overall glove performance (74%), and appropriateness of sizes (83%). Mean pain score from 0 (none) to 10 (worst imaginable) was 3.43 at baseline; during the study, mean scores were 1.15 at rest and 2.29 during movement. Of 61 glove removals, most (72%) were easy/very easy, and 12% had fallen off. Adverse events (wound site or elsewhere) occurred in 15 (65%) patients. Treatment-related adverse events were wound pain (17%), maceration (9%), and stiff fingers (4%). The AQUACEL(®) Ag BURN glove was well tolerated in the management of partial-thickness hand burn. Many patients used only one glove. When glove changes were required, they were usually quick and easy. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.
Grasp Assist Device with Automatic Mode Control Logic
NASA Technical Reports Server (NTRS)
Laske, Evan (Inventor); Davis, Donald R. (Inventor); Ihrke, Chris A. (Inventor)
2018-01-01
A system includes a glove, sensors, actuator assemblies, and controller. The sensors include load sensors which measure an actual grasping force and attitude sensors which determine a glove attitude. The actuator assembly provides a grasp assist force to the glove. Respective locations of work cells in the work environment and permitted work tasks for each work cell are programmed into the controller. The controller detects the glove location and attitude. A work task is selected by the controller for the location. The controller calculates a required grasp assist force using measured actual grasping forces from the load sensors. The required grasp assist force is applied via the glove using the actuator assembly to thereby assist the operator in performing the identified work task.
75 FR 36362 - Procurement List Additions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-25
... additions to the Procurement List. Glove, Mechanic's A commercial company submitted comments objecting to... provide the mechanic's gloves in compliance with the Acts cited by CamelBak in its correspondence to the... Accordingly, the following products and services are added to the Procurement List: Products Glove, Mechanic's...
[Migrants from disposable gloves and residual acrylonitrile].
Wakui, C; Kawamura, Y; Maitani, T
2001-10-01
Disposable gloves made from polyvinyl chloride with and without di(2-ethylhexyl) phthalate (PVC-DEHP, PVC-NP), polyethylene (PE), natural rubber (NR) and nitrile-butadiene rubber (NBR) were investigated with respect to evaporation residue, migrated metals, migrants and residual acrylonitrile. The evaporation residue found in n-heptane was 870-1,300 ppm from PVC-DEHP and PVC-NP, which was due to the plasticizers. Most of the PE gloves had low evaporation residue levels and migrants, except for the glove designated as antibacterial, which released copper and zinc into 4% acetic acid. For the NR and NBR gloves, the evaporation residue found in 4% acetic acid was 29-180 ppm. They also released over 10 ppm of calcium and 6 ppm of zinc into 4% acetic acid, and 1.68-8.37 ppm of zinc di-ethyldithiocarbamate and zinc di-n-butyldithiocarbamate used as vulcanization accelerators into n-heptane. The acrylonitrile content was 0.40-0.94 ppm in NBR gloves.
Occult glove perforation during ophthalmic surgery.
Apt, L; Miller, K M
1992-01-01
We examined the latex surgical gloves used by 56 primary surgeons in 454 ophthalmic surgical procedures performed over a 7-month period. Of five techniques used to detect pinholes, air inflation with water submersion and compression was found to be the most sensitive, yielding a 6.80% prevalence in control glove pairs and a 21.8% prevalence in postoperative study glove pairs, for a 15.0% incidence of surgically induced perforations (P = 0.000459). The lowest postoperative perforation rate was 11.4% for cataract and intraocular lens surgery, and the highest was 41.7% for oculoplastic procedures. Factors that correlated significantly with the presence of glove perforations as determined by multiple logistic regression analysis were oculoplastic and pediatric ophthalmology and strabismus surgical procedures, surgeon's status as a fellow in training, operating time, and glove size. The thumb and index finger of the nondominant hand contained the largest numbers of pinholes. These data suggest strategies for reducing the risk of cross-infection during ophthalmic surgery. PMID:1494836
Constructing Gloved wings for aerodynamic studies
NASA Technical Reports Server (NTRS)
Bohn-Meyer, Marta R.
1988-01-01
Recently, two aircraft from the Dryden Flight Research Facility were used in the general study of natural laminar flow (NLF). The first, an F-14A aircraft on short-term loan from the Navy, was used to investigate transonic natural laminar flow. The second, an F-15A aircraft on long-term loan from the Air Force, was used to examine supersonic NLF. These tests were follow-on experiments to the NASA F-111 NLF experiment conducted in 1979. Both wings of the F-14A were gloved, in a two-phased experiment, with full-span(upper surface only) airfoil shapes constructed primarily of fiberglass, foam, and resin. A small section of the F-15A right wing was gloved in a similar manner. Each glove incorporated provisions for instrumentation to measure surface pressure distributions. The F-14A gloves also had provisions for instrumentation to measure boundary layer profiles, acoustic environments, and surface pitot pressures. Discussions of the techniques used to construct the gloves and to incorporate the required instrumentation are presented.
Optical HMI with biomechanical energy harvesters integrated in textile supports
NASA Astrophysics Data System (ADS)
De Pasquale, G.; Kim, SG; De Pasquale, D.
2015-12-01
This paper reports the design, prototyping and experimental validation of a human-machine interface (HMI), named GoldFinger, integrated into a glove with energy harvesting from fingers motion. The device is addressed to medical applications, design tools, virtual reality field and to industrial applications where the interaction with machines is restricted by safety procedures. The HMI prototype includes four piezoelectric transducers applied to the fingers backside at PIP (proximal inter-phalangeal) joints, electric wires embedded in the fabric connecting the transducers, aluminum case for the electronics, wearable switch made with conductive fabrics to turn the communication channel on and off, and a LED. The electronic circuit used to manage the power and to control the light emitter includes a diodes bridge, leveling capacitors, storage battery and switch made by conductive fabric. The communication with the machine is managed by dedicated software, which includes the user interface, the optical tracking, and the continuous updating of the machine microcontroller. The energetic benefit of energy harvester on the battery lifetime is inversely proportional to the activation time of the optical emitter. In most applications, the optical port is active for 1 to 5% of the time, corresponding to battery lifetime increasing between about 14% and 70%.
Jurewicz, Joanna; Hanke, Wojciech; Sobala, Wojciech; Ligocka, Danuta
2009-01-01
The purpose of our study was to determine the level of skin contamination by azoxystrobin in a group of women tending cucumbers in a vegetable-growing greenhouse after restricted entry intervals expired. Exposure samples were assessed on two days during the spring: first entry on the day after spraying of azoxystrobin and second entry six days later. Dermal exposure was measured by using patches on the outside of clothing and sampling gloves underneath regular working gloves. Pesticide deposited on clothing patches and gloves as a substitute for skin deposition was determined by liquid chromatography and mass spectrometry (LC-MS/MS). The study has shown that workers in a Polish greenhouse are exposed to pesticides at re-entry into the greenhouse after pesticides were sprayed several days earlier. Azoxystrobin has been detected on hands, shoulders and chest. Higher levels of azoxystrobin were found on the cotton gloves of women tending the vegetables than on the patches. The levels decreased (by about 60%) on the patches and increased (by about 250%) on the cotton gloves between the two days of measurement. Women working in a vegetable-growing greenhouse and not directly engaged in the process of spraying experience a measurable dermal exposure to azoxystrobin. The protective gloves constitute a source of secondary exposure rather than protecting employees' hands from contact with the pesticide. More efficient personal protective gloves for proper protection of women working in vegetable greenhouses are needed.
21 CFR 878.4460 - Surgeon's glove.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Surgeon's glove. 878.4460 Section 878.4460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4460 Surgeon's glove. (a...
21 CFR 878.4460 - Surgeon's glove.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Surgeon's glove. 878.4460 Section 878.4460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4460 Surgeon's glove. (a...
21 CFR 878.4460 - Surgeon's glove.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Surgeon's glove. 878.4460 Section 878.4460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4460 Surgeon's glove. (a...
Status of the Prototype Pulsed Photonuclear Assessment (PPA) Inspection System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prototype Photonuclear Inspection Technoloby - An
Prototype Photonuclear Inspection Technology – An Integrated Systems Approach* James L. Jonesa, Daren R. Normana, Kevin J. Haskella, James W. Sterbentza, Woo Y. Yoona, Scott M. Watsona, James T. Johnsona, John M. Zabriskiea, Calvin E. Mossb, Frank Harmonc a – Idaho National Laboratory, P.O. Box 1625-2802, Idaho Falls, Idaho 83415-2802 b – Los Alamos National Laboratory, P.O. Box 1663, MS B228, Los Alamos, New Mexico, 87585 c – Idaho State University, 1500 Alvin Ricken Dr., Pocatello, Idaho 83201 Active interrogation technologies are being pursued in order to address many of today’s challenging inspection requirements related to both nuclear and non-nuclearmore » material detection. The Idaho National Laboratory, along with the Los Alamos National Laboratory and the Idaho State University’s Idaho Accelerator Center, continue to develop electron accelerator-based, photonuclear inspection technologies for the detection of shielded nuclear material within air-, rail-, and especially, maritime-cargo containers. This paper presents an overview and status of the prototype Pulsed Photonuclear Assessment (PPA) inspection system and its ability to detect shielded nuclear material by focusing on the integration of three major detection system components: delayed neutron measurement, delayed gamma-ray measurements, and a transmission, gray-scale mapping for shield material detection. Areas of future development and advancement within each detection component will be presented. *Supported in part by the Department of Homeland Security under DOE-ID Contract Number DE-AC07-99ID13727. POC: James L. Jones, 208-526-1730« less
76 FR 82279 - Procurement List; Additions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-30
... Micro, Light Blue, Size 5.5''. NSN: 6515-00-NIB-0722--Gloves, Surgical, Powder-free, Esteem Micro, Light Blue, Size 6''. NSN: 6515-00-NIB-0723--Gloves, Surgical, Powder-free, Esteem Micro, Light Blue, Size 6.5''. NSN: 6515-00-NIB-0724--Gloves, Surgical, Powder-free, Esteem Micro, Light Blue, Size 7'' . NSN...
21 CFR 878.4470 - Surgeon's gloving cream.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Surgeon's gloving cream. 878.4470 Section 878.4470 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4470 Surgeon's gloving cream...
21 CFR 878.4470 - Surgeon's gloving cream.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Surgeon's gloving cream. 878.4470 Section 878.4470 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4470 Surgeon's gloving cream...
21 CFR 878.4470 - Surgeon's gloving cream.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Surgeon's gloving cream. 878.4470 Section 878.4470 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4470 Surgeon's gloving cream...
21 CFR 878.4470 - Surgeon's gloving cream.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgeon's gloving cream. 878.4470 Section 878.4470 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4470 Surgeon's gloving cream...
21 CFR 878.4470 - Surgeon's gloving cream.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Surgeon's gloving cream. 878.4470 Section 878.4470 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4470 Surgeon's gloving cream...
75 FR 68394 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-05
... Woven and Knit impregnated with Flat Dipped Rubber/Plastic Gloves. SUMMARY: The U. S. Small Business... Flat Dipped Rubber/Plastic Gloves, under North American Industry Classification System (NAICS) code... Rule for Woven and Knit impregnated with Flat Dipped Rubber/Plastic Gloves under PSC 9999...
75 FR 52789 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-27
... for Woven and Knit impregnated with Flat Dipped Rubber/Plastic Gloves. SUMMARY: The U.S. Small... for woven and knit impregnated with flat dipped rubber/plastic gloves, under the North American... Dipped Rubber/Plastic Gloves manufacturers. If granted, the waiver would allow otherwise qualified small...
Glove Changing Habits in Mobile Food Vendors in New York City.
Basch, Corey H; Guerra, Laura A; MacDonald, Zerlina; Marte, Myladys; Basch, Charles E
2015-08-01
The aim of this study was to determine how often mobile food cart vendors in New York City (NYC) changed gloves after exchanging money, which is required by the current NYC health code as one of various measures to prevent foodborne illness. A total of 100 carts (10 carts in 10 zones) throughout Manhattan were observed. In the majority (56.9%, n = 1,026) of the 1,804 money exchanges, food cart vendors did not change their gloves. Not changing gloves after exchanging money was widespread regardless of food type served (46.6% for breakfast to 63.7% for lunch), and across all 10 zones. Not changing gloves after touching money may result in indirect transmission of agents of disease and pose health risks for consumers.
Thermal comfort of dual-chamber ski gloves
NASA Astrophysics Data System (ADS)
Dotti, F.; Colonna, M.; Ferri, A.
2017-10-01
In this work, the special design of a pair of ski gloves has been assessed in terms of thermal comfort. The glove 2in1 Gore-Tex has a dual-chamber construction, with two possible wearing configurations: one called “grip” to maximize finger flexibility and one called “warm” to maximize thermal insulation in extremely cold conditions. The dual-chamber gloves has been compared with two regular ski gloves produced by the same company. An intermittent test on a treadmill was carried out in a climatic chamber: it was made of four intense activity phases, during which the volunteer ran at 9 km/h on a 5% slope for 4 minutes, spaced out by 5-min resting phases. Finger temperature measurements were compared with the thermal sensations expressed by two volunteers during the test.
Analysis of Low-Speed Stall Aerodynamics of a Swept Wing with Laminar-Flow Glove
NASA Technical Reports Server (NTRS)
Bui, Trong T.
2014-01-01
Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.
Analysis of Low Speed Stall Aerodynamics of a Swept Wing with Laminar Flow Glove
NASA Technical Reports Server (NTRS)
Bui, Trong T.
2014-01-01
Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.
Transmission of vibration through gloves: effects of material thickness.
Md Rezali, Khairil Anas; Griffin, Michael J
2016-08-01
It might be assumed that increasing the thickness of a glove would reduce the vibration transmitted to the hand. Three material samples from an anti-vibration glove were stacked to produce three thicknesses: 6.4, 12.8 and 19.2 mm. The dynamic stiffnesses of all three thicknesses, the apparent mass at the palm and the finger and the transmission of vibration to the palm and finger were measured. At frequencies from 20 to 350 Hz, the material reduced vibration at the palm but increased vibration at the finger. Increased thickness reduced vibration at the palm but increased vibration at the finger. The measured transmissibilities could be predicted from the material dynamic stiffness and the apparent mass of the palm and finger. Reducing the dynamic stiffness of glove material may increase or decrease the transmission of vibration, depending on the material, the frequency of vibration and the location of measurement (palm or finger). Practitioner Summary: Transmission of vibration through gloves depends on the dynamic response of the hand and the dynamic stiffness of glove material, which depends on material thickness. Measuring the transmission of vibration through gloves to the palm of the hand gives a misleading indication of the transmission of vibration to the fingers.
Handling Heavenly Jewels - 35 Years of Antarctic Meteorite Processing at Johnson Space Center
NASA Technical Reports Server (NTRS)
Satterwhite, C. E.; McBridge, K. M.; Harrington, R.; Schwarz, C. M.
2011-01-01
The ANSMET program began in 1976, and since that time more than 18,000 meteorites have been processed in the Meteorite Processing Lab at Johnson Space Center in Houston, TX[1]. The meteorites are collected and returned to JSC on a freezer truck and remain frozen until they are initially processed. Initial Processing of Meteorites: Initial processing involves drying the meteorites in a nitrogen glove box for 24 to 48 hours, photographing, measuring, weighing and writing a description of the interior and exterior. The meteorite is broken and a representative sample is sent to the Smithsonian Institution for classification. Newsletter & Requests: Once initial processing has been complete and the meteorites have been classified, the information is published in the Antarctic Meteorite Newsletter[2,3]. The newsletter is published twice yearly and is sent electronically to researchers around the world and is also available on line. Researchers are asked to fill out a request form and submit it to the Meteorite Working Group secretary. All sample requests will be reviewed by either the meteorite curator or the Meteorite Working Group de-pending on the type of meteorite and the research being conducted. Processing for Sample Requests: In the meteorite processing lab, meteorite samples are prepared several different ways. Most samples are prepared as chips obtained by use of stainless steel chisels in a chipping bowl or rock splitter. In special situations where a researcher needs a slab the meteorite samples can be bandsawed in a dry nitrogen glove box with a diamond blade, no liquids are ever introduced into the cabinet. The last type of sample preparation is thin/thick sections. The meteorite thin section lab at JSC can prepare standard 30-micron thin sections, thick sections of variable thickness (100 to 200 microns), or demountable sections using superglue. Information for researchers: It is important that re-searchers fill the sample request form completely, in order to make sure the meteorite is processed correctly[4]. Re-searchers should list any special requirements on the form, i.e. packaging of samples (poly vs. stainless), thick sections and thickness needed, superglue needed, interior chips, exterior chips, fusion crust, contamination issues, all concerns should be listed so processing can be done accurately and any concerns the researcher has can be addressed be-fore the meteorites are broken.
Non-verbal communication through sensor fusion
NASA Astrophysics Data System (ADS)
Tairych, Andreas; Xu, Daniel; O'Brien, Benjamin M.; Anderson, Iain A.
2016-04-01
When we communicate face to face, we subconsciously engage our whole body to convey our message. In telecommunication, e.g. during phone calls, this powerful information channel cannot be used. Capturing nonverbal information from body motion and transmitting it to the receiver parallel to speech would make these conversations feel much more natural. This requires a sensing device that is capable of capturing different types of movements, such as the flexion and extension of joints, and the rotation of limbs. In a first embodiment, we developed a sensing glove that is used to control a computer game. Capacitive dielectric elastomer (DE) sensors measure finger positions, and an inertial measurement unit (IMU) detects hand roll. These two sensor technologies complement each other, with the IMU allowing the player to move an avatar through a three-dimensional maze, and the DE sensors detecting finger flexion to fire weapons or open doors. After demonstrating the potential of sensor fusion in human-computer interaction, we take this concept to the next level and apply it in nonverbal communication between humans. The current fingerspelling glove prototype uses capacitive DE sensors to detect finger gestures performed by the sending person. These gestures are mapped to corresponding messages and transmitted wirelessly to another person. A concept for integrating an IMU into this system is presented. The fusion of the DE sensor and the IMU combines the strengths of both sensor types, and therefore enables very comprehensive body motion sensing, which makes a large repertoire of gestures available to nonverbal communication over distances.
Birnbach, David J; Rosen, Lisa F; Fitzpatrick, Maureen; Carling, Philip; Arheart, Kristopher L; Munoz-Price, L Silvia
2015-04-01
Oral flora, blood-borne pathogens, and bacterial contamination pose a direct risk of infection to patients and health care workers. We conducted a study in a simulated operating room using a newly validated technology to determine whether the use of 2 sets of gloves, with the outer set removed immediately after endotracheal intubation, may reduce this risk. Forty-one anesthesiology residents (PGY 2-4) were enrolled in a study consisting of individual or group simulation sessions. On entry to the simulated operating room, the residents were asked to perform an anesthetic induction and tracheal intubation timed to approximately 6 minutes; they were unaware of the study design. Of the 22 simulation sessions, 11 were conducted with the intubating resident wearing single gloves, and 11 with the intubating resident using double gloves with the outer pair removed after verified intubation. Before the start of the scenario, we coated the lips and inside of the mouth of the mannequin with a fluorescent marking gel as a surrogate pathogen. After the simulation, an observer examined 40 different sites using a handheld ultraviolet light in the operating room to determine the transfer of surrogate pathogens to the patient and the patient's environment. Residents who wore double gloves were instructed by a confederate nurse to remove the outer set immediately after completion of the intubation. Forty sites of potential intraoperative pathogen spread were identified and assigned a score. The difference in the rate of contamination between anesthesiology residents who wore single gloves versus those with double gloves was clinically and statistically significant. The number of sites that were contaminated in the operating room when the intubating resident wore single gloves was 20.3 ± 1.4 (mean ± SE); the number of contaminated sites when residents wore double gloves was 5.0 ± 0.7 (P < 0.001). The results of this study suggest that when an anesthesiologist wears 2 sets of gloves during laryngoscopy and intubation and then removes the outer set immediately after intubation, the contamination of the intraoperative environment is dramatically reduced.
Haptic Glove Technology: Skill Development through Video Game Play
ERIC Educational Resources Information Center
Bargerhuff, Mary Ellen; Cowan, Heidi; Oliveira, Francisco; Quek, Francis; Fang, Bing
2010-01-01
This article introduces a recently developed haptic glove system and describes how the participants used a video game that was purposely designed to train them in skills that are needed for the efficient use of the haptic glove. Assessed skills included speed, efficiency, embodied skill, and engagement. The findings and implications for future…
The Use of Latex Gloves in the School Setting
ERIC Educational Resources Information Center
Purcell, Cathy Koeppen
2006-01-01
In 1987, when the U.S. Centers for Disease Control and Prevention recommended the use of universal precautions in response to the HIV/AIDS epidemic, the demand for medical gloves dramatically increased. Unfortunately, the manufacturing techniques for the most widely-used gloves--natural rubber latex--also changed, in order to expedite production.…
Axisa, F; Gehin, C; Delhomme, G; Collet, C; Robin, O; Dittmar, A
2004-01-01
Improvement of the quality and efficiency of the quality of health in medicine, at home and in hospital becomes more and more important Designed to be user-friendly, smart clothes and gloves fit well for such a citizen use and health monitoring. Analysis of the autonomic nervous system using non-invasive sensors provides information for the emotional, sensorial, cognitive and physiological analysis. MARSIAN (modular autonomous recorder system for the measurement of autonomic nervous system) is a wrist ambulatory monitoring and recording system with a smart glove with sensors for the detection of the activity of the autonomic nervous system. It is composed of a "smart tee shirt", a "smart glove", a wrist device and PC which records data. The smart glove is one of the key point of MARSIAN. Complex movements, complex geometry, sensation make smart glove designing a challenge. MARSIAN has a large field of applications and researches (vigilance, behaviour, sensorial analysis, thermal environment for human, cognition science, sport, etc...) in various fields like neurophysiology, affective computing and health monitoring.
Teacher's Guide to Water Play: The MATCH Box Project; Prototype Edition.
ERIC Educational Resources Information Center
Olson, Nancy; And Others
The multimedia kit on water was designed for use by nursery school and first grade children. Water is an intriguing part of a child's world; for this reason, water was chosen as the medium for this set of instructional materials. The child's natural way of exploring his environment is through play; he is really learning ways to discover and…
Teacher's Guide to Imagination Unlimited. The MATCH Book Project; Prototype Edition.
ERIC Educational Resources Information Center
Williams, Susan; Williamson, Sharon
The idea of this box of multimedia instructional materials is to surround the children with curious and wonderful objects and experiences which will stimulate them to self-expression. The kit provides a set of unusual objects: two movies about a rainshower, one from a weatherman's point of view and one as seen through the eyes of an artist; a set…
NASA Astrophysics Data System (ADS)
Davis, L.; Weatherley, J.; Bhushan, S.; Khan, H.; de La Chica, S.; Deardorff, R.
2004-12-01
An exciting pilot program took place this summer, pioneering the development of Digital Library for Earth System Education (DLESE) Teaching Boxes with the Univ. of CA. Berkeley Museum of Paleontology, SF State Univ., USGS and 7 middle/high school teachers from the San Francisco area. This session will share the DLESE Teaching Box concept, explain the pilot program, and explore the tremendous opportunities for expanding this notion to embrace interdisciplinary approaches to learning about the Earth in the undergraduate science and pre-service teaching arenas. A Teaching Box is a metaphor for an online assembly of interrelated learning concepts, digital resources, and cohesive narration that bridges the gap between discrete resources and understanding. Within a Teaching Box, an instructor or student can pick a topic and see the concepts that build an understanding of that topic, explore online resources that support learning of those concepts, and benefit from the narration (the glue) that weaves concepts, activities, and background information together into a complete teaching/learning story. In this session, we will demonstrate the emerging Teaching Box prototypes and explore how this platform may promote STEM learning by utilizing DLESE tools and services in ways that begin to blur traditional disciplinary boundaries, overcome limitations of discipline-specific vocabularies, and foster collaboration. We will show ways in which new DLESE Web Services could support learning in this highly contextualized environment. We will see glimpses of how learners and educators will be able to modify or create their own Teaching Boxes specific to a unit of study or course, and perhaps share them with the Earth Science Education community. We will see ways to stay abreast of current Earth events, emerging research, and real-time data and incorporate such dynamic information into one learning environment. Services will be described and demonstrated in the context of Teaching Boxes: - DLESE Web Services provide a programmatic interface that allows the Teaching Box (or any web page) to have the same DLESE search, bookmarking features, and data management that are found at the DLESE web site. - DLESE Smart Links are hyperlinks that can be created by anyone and implemented as easily as defining a specific query. Clicking a Smart Link displays a list of resources that corresponds to the specific query. We'll talk about how this service can help to bridge the gap between vocabularies and disciplines and the interesting possibilities it presents for contextualizing searches and building custom topical menus. - The Really Simple Syndication (RSS) service delivers online information immediately, and allows end-users to subscribe to receive regular news, events, and data on a given Teaching Box topic. This opens the door to event-based learning. - Strand Maps, developed by the AAAS, are diagrams of interconnected learning concepts across a range of science, technology, engineering, and mathematics disciplines. The University of Colorado and its project partners are developing the Strand Map Service (SMS) to provide an interactive interface to interrelated learning goals, content knowledge, (including student misconceptions) and educational resources in the National Science Digital Library and DLESE.
Checchi, L; D'Achille, C; Conti, S
1991-01-01
The diffusion of transmissible diseases such as the Acquired Immunodeficiency Syndrome, well known as AIDS, has induced in the population a great sensibility to the problem of disease transmission. Dentists and patients, because of peculiar features of oral environment and dental procedures, are very exposed to these risks. For this reason every technique which reduces the risk of cross-infections patient to patient and patient to dentist to patient are absolutely necessary. From this point of view the use of gloves is very important to protect dental operator and patients. The aim of this study is: a) to stress the importance of mechanical barriers, like gloves, in dentistry in order to sensitize dental practitioners to the use of gloves; b) to underline that the quality of dental gloves in Italy is lower than in other countries which have a quality standard.
In-Situ Leak Testing And Replacement Of Glovebox Isolator, Or Containment Unit Gloves
Castro, Julio M.; Macdonald, John M.; Steckle, Jr., Warren P.
2004-11-02
A test plug for in-situ testing a glove installed in a glovebox is provided that uses a top plate and a base plate, and a diametrically expandable sealing mechanism fitting between the two plates. The sealing mechanism engages the base plate to diametrically expand when the variable distance between the top plate and the bottom plate is reduced. An inlet valve included on the top plate is used to introducing a pressurized gas to the interior of the glove, and a pressure gauge located on the top plate is used to monitor the interior glove pressure.
Mutsuga, M; Wakui, C; Kawamura, Y; Maitani, T
2002-11-01
In Japan, disposable gloves made from nitrile-butadiene rubber (NBR) are frequently used in contact with foods. In a previous paper, we investigated substances migrating from various gloves made of polyvinyl chloride, polyethylene, natural rubber and NBR. Zinc di-n-butyldithiocarbamate (ZDBC), diethyldithiocarbamate (ZDEC) used as vulcanization accelerators, di(2-ethylhexyl)phthalate (DEHP) used as a plasticizer and many unknown compounds that migrated from NBR gloves into n-heptane were detected by GC/MS. In this paper, six unknown compounds were obtained from one kind of NBR glove by n-hexane extraction and each was isolated by silica gel chromatography. From the results of NMR and mass spectral analysis of the six unknown compounds, their structures are proposed as 1,4-dione-2,5-bis(1,1-dimethylpropyl)cyclohexadiene (1), 2-(1,1-dimethylethyl)-4-(1,1,3,3-tetra methylbutyl)phenol (2), 2,6-bis(1,1-dimethylethyl)-4-(1,1,3,3-tetramethylbutyl)phenol (3), 2,4-bis(1,1,3,3-tetramethylbutyl)phenol (4), 2-(1,1-dimethylethyl)4,6-bis(1,1,3,3-tetramethylbutyl)phenol (5) and 2,4,6-tris(1,1,3,3-tetramethylbutyl)phenol (6). Compound 1 was observed in five of the seven kinds of NBR gloves, and compounds 2-4 and 6, which are not listed in Chemical Abstract (CA), were present in four kinds of gloves.
Nathan, Dominic E; Johnson, Michelle J; McGuire, John R
2009-01-01
Hand and arm impairment is common after stroke. Robotic stroke therapy will be more effective if hand and upper-arm training is integrated to help users practice reaching and grasping tasks. This article presents the design, development, and validation of a low-cost, functional electrical stimulation grasp-assistive glove for use with task-oriented robotic stroke therapy. Our glove measures grasp aperture while a user completes simple-to-complex real-life activities, and when combined with an integrated functional electrical stimulator, it assists in hand opening and closing. A key function is a new grasp-aperture prediction model, which uses the position of the end-effectors of two planar robots to define the distance between the thumb and index finger. We validated the accuracy and repeatability of the glove and its capability to assist in grasping. Results from five nondisabled subjects indicated that the glove is accurate and repeatable for both static hand-open and -closed tasks when compared with goniometric measures and for dynamic reach-to-grasp tasks when compared with motion analysis measures. Results from five subjects with stroke showed that with the glove, they could open their hands but without it could not. We present a glove that is a low-cost solution for in vivo grasp measurement and assistance.
Janota, Jan; Šebková, Sylva; Višňovská, Magda; Kudláčková, Jana; Hamplová, Drahomíra; Zach, Jiří
2014-10-01
To assess the impact of a hand hygiene protocol, using hand washing, alcohol hand rub and gloves when caring for preterm infants born after 31 weeks of gestation, on the incidence of neonatal late onset sepsis (LOS). All babies delivered between 32 + 0 and 36 + 6 weeks gestation and admitted to the neonatal intensive care unit during a 14-month period were included. We followed a hand hygiene protocol with hand washing and alcohol hand rub (hand rub period) for the first 7 months and a protocol of hand washing, alcohol hand rub and gloves (gloves period) for the second 7 months. The hand rub and gloves groups consisted of 111 and 89 patients, respectively. Five patients were diagnosed with a total of six episodes of LOS in the hand rub group, and the incidence of LOS during the hand rub period was 2.99/1000 hospital days and 54.1/1000 admissions. There were no patients diagnosed with LOS during the gloves period (significant decrease, p = 0.028). Using a hand hygiene protocol with hand washing, hand rub and gloves significantly reduced the incidence of LOS in preterm newborns, and the results suggest that it may produce a sustained improvement in the infection rate. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Tomson, Tanja; Zary, Nabil
2014-01-01
Introduction. Antimicrobial resistance is a global health issue. Studies have shown that improved antibiotic prescription education among healthcare professionals reduces mistakes during the antibiotic prescription process. The aim of this study was to investigate novel educational approaches that through the use of Augmented Reality technology could make use of the real physical context and thereby enrich the educational process of antibiotics prescription. The objective is to investigate which type of information related to antibiotics could be used in an augmented reality application for antibiotics education. Methods. This study followed the Design-Based Research Methodology composed of the following main steps: problem analysis, investigation of information that should be visualized for the training session, and finally the involvement of the end users the development and evaluation processes of the prototype. Results. Two of the most important aspects in the antibiotic prescription process, to represent in an augmented reality application, are the antibiotic guidelines and the side effects. Moreover, this study showed how this information could be visualized from a mobile device using an Augmented Reality scanner and antibiotic drug boxes as markers. Discussion. In this study we investigated the usage of objects from a real physical context such as drug boxes and how they could be used as educational resources. The logical next steps are to examine how this approach of combining physical and virtual contexts through Augmented Reality applications could contribute to the improvement of competencies among healthcare professionals and its impact on the decrease of antibiotics resistance. PMID:25548733
Nifakos, Sokratis; Tomson, Tanja; Zary, Nabil
2014-01-01
Introduction. Antimicrobial resistance is a global health issue. Studies have shown that improved antibiotic prescription education among healthcare professionals reduces mistakes during the antibiotic prescription process. The aim of this study was to investigate novel educational approaches that through the use of Augmented Reality technology could make use of the real physical context and thereby enrich the educational process of antibiotics prescription. The objective is to investigate which type of information related to antibiotics could be used in an augmented reality application for antibiotics education. Methods. This study followed the Design-Based Research Methodology composed of the following main steps: problem analysis, investigation of information that should be visualized for the training session, and finally the involvement of the end users the development and evaluation processes of the prototype. Results. Two of the most important aspects in the antibiotic prescription process, to represent in an augmented reality application, are the antibiotic guidelines and the side effects. Moreover, this study showed how this information could be visualized from a mobile device using an Augmented Reality scanner and antibiotic drug boxes as markers. Discussion. In this study we investigated the usage of objects from a real physical context such as drug boxes and how they could be used as educational resources. The logical next steps are to examine how this approach of combining physical and virtual contexts through Augmented Reality applications could contribute to the improvement of competencies among healthcare professionals and its impact on the decrease of antibiotics resistance.
Wireless physiological monitoring system for psychiatric patients.
Rademeyer, A J; Blanckenberg, M M; Scheffer, C
2009-01-01
Patients in psychiatric hospitals that are sedated or secluded are at risk of death or injury if they are not continuously monitored. Some psychiatric patients are restless and aggressive, and hence the monitoring device should be robust and must transmit the data wirelessly. Two devices, a glove that measures oxygen saturation and a dorsally-mounted device that measures heart rate, skin temperature and respiratory rate were designed and tested. Both devices connect to one central monitoring station using two separate Bluetooth connections, ensuring a completely wireless setup. A Matlab graphical user interface (GUI) was developed for signal processing and monitoring of the vital signs of the psychiatric patient. Detection algorithms were implemented to detect ECG arrhythmias such as premature ventricular contraction and atrial fibrillation. The prototypes were manufactured and tested in a laboratory setting on healthy volunteers.
76 FR 62391 - Procurement List; Proposed Additions and Deletions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-07
... Blue, Size 5.5'' NSN: 6515-00-NIB-0722--Gloves, Surgical, Powder-free, Esteem Micro, Light Blue, Size 6'' NSN: 6515-00-NIB-0723--Gloves, Surgical, Powder-free, Esteem Micro, Light Blue, Size 6.5'' NSN: 6515-00-NIB-0724--Gloves, Surgical, Powder-free, Esteem Micro, Light Blue, Size 7'' NSN: 6515-00-NIB-0725...
Kock, Tobias J.; Liedtke, Theresa L.; Ekstrom, Brian K.; Tomka, Ryan G.; Rondorf, Dennis W.
2014-01-01
Collection of juvenile salmonids at Cowlitz Falls Dam is a critical part of the effort to restore salmon in the upper Cowlitz River because the majority of fish that are not collected at the dam pass downstream and enter a large reservoir where they become landlocked and lost to the anadromous fish population. However, the juvenile fish collection system at Cowlitz Falls Dam has failed to achieve annual collection goals since it first began operating in 1996. Since that time, numerous modifications to the fish collection system have been made and several prototype collection structures have been developed and tested, but these efforts have not substantially increased juvenile fish collection. Studies have shown that juvenile steelhead (Oncorhynchus mykiss), coho salmon (Oncorhynchus kisutch), and Chinook salmon (Oncorhynchus tshawytscha) tend to locate the collection entrances effectively, but many of these fish are not collected and eventually pass the dam through turbines or spillways. Tacoma Power developed a prototype weir box in 2009 to increase capture rates of juvenile salmonids at the collection entrances, and this device proved to be successful at retaining those fish that entered the weir. However, because of safety concerns at the dam, the weir box could not be deployed near a spillway gate where the prototype was tested, so the device was altered and re-deployed at a different location, where it was evaluated during 2013. The U.S. Geological Survey conducted an evaluation using radiotelemetry to monitor fish behavior near the weir box and collection flumes. The evaluation was conducted during April–June 2013. Juvenile steelhead and coho salmon (45 per species) were tagged with a radio transmitter and passive integrated transponder (PIT) tag, and released upstream of the dam. All tagged fish moved downstream and entered the forebay of Cowlitz Falls Dam. Median travel times from the release site to the forebay were 0.8 d for steelhead and 1.2 d for coho salmon. Most fish spent several days in the dam forebay; median forebay residence times were 4.4 d for juvenile steelhead and 5.7 d for juvenile coho salmon. A new radio transmitter model was used during the study period. The transmitter had low detection probabilities on underwater antennas located within the collection system, which prevented us from reporting performance metrics (discovery efficiency, entrance efficiency, retention efficiency) that are traditionally used to evaluate fish collection systems. Most tagged steelhead (98 percent) and coho salmon (84 percent) were detected near the weir box or collection flume entrances during the study period; 39 percent of tagged steelhead and 55 percent of tagged coho salmon were detected at both entrances. Sixty-three percent of the tagged steelhead that were detected at both entrances were first detected at the weir box, compared to 52 percent of the coho salmon. Twelve steelhead and 15 coho salmon detected inside the weir box eventually left the device and were collected in collection flumes or passed the dam. Overall, collection rates were relatively high during the study period. Sixty-five percent of the steelhead and 80 percent of the coho salmon were collected during the study, and most of the remaining fish passed the dam and entered the tailrace (24 percent of steelhead; 13 percent of coho salmon). The remaining 11 percent of steelhead and 7 percent of coho salmon did not pass the dam while their transmitters were operating. We were able to confirm collection of tagged fish at the fish facility using three approaches: (1) detection of radio transmitters in study fish; (2) detection of PIT-tags in study fish; (3) observation of study fish by staff at the fish facility. Data from all three methods were used to develop a multistate mark-recapture model that estimated detection probabilities for the various monitoring methods. These estimates then were used to describe the percent of tagged fish that were collected through the weir box and collection flumes. Detection probabilities of PIT-tag antennas in the collection flumes were 0.895 for juvenile steelhead and 0.881 for juvenile coho salmon, although radiotelemetry detection probabilities were 0.654 and 0.646 for the two species, respectively. The multistate model estimates showed that all steelhead and most coho salmon (94.5 percent) that were collected at the dam entered the collection system through the flumes rather than through the weir box. None of the tagged steelhead and only 5.5 percent of the tagged coho salmon were collected through the weir box. These data show that juvenile steelhead and coho salmon collection rates were much higher through the collection flumes than through the weir box. Low detection probabilities of tagged fish in the fish collection system resulted in uncertainty for some aspects of our evaluation. Missing detection records within the collection system for fish that were known to have been collected resulted in four tagged steelhead and seven tagged coho salmon being removed from the dataset, which was used to assess discovery rates of the weir box and collection flumes. However, the multistate model allowed us to provide unbiased estimates of the percentage of tagged fish that were collected through each route, and these data showed that few fish were collected through the weir box. Overall, the fish collection system performed reasonably well in collecting juvenile steelhead and coho salmon during the 2013 collection season. Fish collection efficiency estimates from the Washington Department of Fish and Wildlife showed that steelhead collection efficiency was slightly higher than the 10-year average (46 percent compared to 42 percent), whereas coho salmon collection efficiency was more than twice as high as the 10-year average (63 percent compared to 30 percent). However, the performance of the weir box was poor because most fish were collected through the collection flumes.
Glove permeation by semiconductor processing mixtures containing glycol-ether derivatives.
Zellers, E T; Ke, H Q; Smigiel, D; Sulewski, R; Patrash, S J; Han, M W; Zhang, G Z
1992-02-01
Results of permeation tests of several glove materials challenged with semiconductor processing formulations containing glycolether derivatives are described. Commercial glove samples of nitrile rubber (Edmont), natural rubber (Edmont and Baxter), butyl rubber (North), PVC Baxter), a natural rubber/neoprene/nitrile blend (Pioneer), and a natural rubber/neoprene blend (Playtex) were tested according to the ASTM F739-85 permeation test method (open-loop configuration). The liquid formulations examined included a positive photoresist thinner containing 2-ethoxyethyl acetate (2-EEA), n-butyl acetate, and xylene; a positive photoresist containing 2-EEA, n-butyl acetate, xylene, polymer resins, and photoactive compounds; a negative photoresist containing 2-methoxyethanol (2-ME), xylene, and cyclized poly(isoprene); and pure 2-methoxyethyl acetate (2-MEA), which is the solvent used in a commercial electron-beam resist. With the exception of the negative photoresist, butyl rubber provided the highest level of protection against the solvent mixtures tested, with no breakthrough observed after 4 hr of continuous exposure at 25 degrees C. Nitrile rubber provided the highest level of protection against the negative photoresist and reasonably good protection against initial exposure to the other solvent mixtures. Gloves consisting of natural rubber or natural rubber blends provided less protection against the mixtures than either nitrile or butyl rubber. For most of the glove samples, permeation of the glycol-ether derivatives contained in the mixtures was faster than that predicted from the permeation of the pure solvents. Increasing the exposure temperature from 25 to 37 degrees C did not significantly affect the performance of the butyl rubber glove. For the other gloves, however, exposures at 37 degrees C resulted in decreases in breakthrough times of 25-75% and increases in steady-state permeation rates of 80-457% relative to values obtained at 25 degrees C. Repeated exposure of nitrile rubber samples resulted in shorter breakthrough times for all mixture components. In fact, exposure for as little as one-half of the nominal breakthrough time followed by air drying overnight resulted in measurable quantities of one or more of the component solvents at the inner surface of the gloves at the beginning of the next exposure. This effect was not observed with the butyl rubber samples. With the exception of the negative photoresist, heating previously exposed nitrile rubber samples at 70 degrees C for 20 hr prior to retesting reduced or eliminated the effects of residual solvents, permitting reuse of the gloves. The use of thin PVC or natural rubber gloves adjacent to the nitrile gloves provided moderate increases in permeation resistance.(ABSTRACT TRUNCATED AT 400 WORDS)
Birnbach, David J; Rosen, Lisa F; Fitzpatrick, Maureen; Carling, Philip; Arheart, Kristopher L; Munoz-Price, L Silvia
2015-11-01
Anesthesiologists may contribute to postoperative infections by means of the transmission of blood and pathogens to the patient and the environment in the operating room (OR). Our primary aims were to determine whether contamination of the IV hub, the anesthesia work area, and the patient could be reduced after induction of anesthesia by removing the risk associated with contaminants on the laryngoscope handle and blade. Therefore, we conducted a study in a simulated OR where some of the participants sheathed the laryngoscope handle and blade in a glove immediately after it was used to perform an endotracheal intubation. Forty-five anesthesiology residents (postgraduate year 2-4) were enrolled in a study consisting of identical simulation sessions. On entry to the simulated OR, the residents were asked to perform an anesthetic, including induction and endotracheal intubation timed to approximately 6 minutes. Of the 45 simulation sessions, 15 were with a control group conducted with the intubating resident wearing single gloves, 15 with the intubating resident using double gloves with the outer pair removed and discarded after verified intubation, and 15 wearing double gloves and sheathing the laryngoscope in one of the outer gloves after intubation. Before the start of the scenario, the lips and inside of the mouth of the mannequin were coated with a fluorescent marking gel. After each of the 45 simulations, an observer examined the OR using an ultraviolet light to determine the presence of fluorescence on 25 sites: 7 on the patient and 18 in the anesthesia environment. Of the 7 sites on the patient, ultraviolet light detected contamination on an average of 5.7 (95% confidence interval, 4.4-7.2) sites under the single-glove condition, 2.1 (1.5-3.1) sites with double gloves, and 0.4 (0.2-1.0) sites with double gloves with sheathing. All 3 conditions were significantly different from one another at P < 0.001. Of the 18 environmental sites, ultraviolet light detected fluorescence on an average of 13.2 (95% confidence interval, 11.3-15.6) sites under the single-glove condition, 3.5 (2.6-4.7) with double gloves, and 0.5 (0.2-1.0) with double gloves with sheathing. Again, all 3 conditions were significantly different from one another at P < 0.001. The results of this study suggest that when an anesthesiologist in a simulated OR sheaths the laryngoscope immediately after endotracheal intubation, contamination of the IV hub, patient, and intraoperative environment is significantly reduced.
An Investigation of the Hypoalgesic Effects of TENS Delivered by a Glove Electrode
Cowan, Stephen; McKenna, Joanne; McCrum-Gardner, Evie; Johnson, Mark I.; Sluka, Kathleen A.; Walsh, Deirdre M.
2009-01-01
This randomized, placebo-controlled, blinded study investigated the hypoalgesic effects of high-frequency transcutaneous electrical nerve stimulation (TENS) delivered via a glove electrode compared with standard self-adhesive electrodes. Fifty-six TENS-naïve, healthy individuals (18 to 50 years old; 28 men, 28 women) were randomly allocated to 1 of 4 groups (n = 14 per group): glove electrode; placebo TENS using a glove electrode; standard electrode; and no treatment control. Active TENS (continuous stimulus, 100 Hz, strong but comfortable intensity) was applied to the dominant forearm/hand for 30 minutes. Placebo TENS was applied using a burst stimulus, 100-Hz frequency, 5-second cycle time for 42 seconds, after which the current amplitude was automatically reset to 0 mA. Pressure pain thresholds (PPTs) were recorded from 3 points on the dominant and nondominant upper limbs before and after TENS. Statistical analyses of dominant PPT data using between-within groups ANOVA showed significant differences between groups at all 3 recording points (P = .01). Post hoc Scheffe tests indicated no significant difference between the standard electrode and glove electrode groups. There was a significant hypoalgesic effect in the standard electrode group compared with the control group and between the glove electrode group and both the control and placebo TENS groups. There was no significant interactive effect between time and group at any of the recording points (P > .05). Perspective This study presents a comparison of the hypoalgesic effects of 2 different types of TENS electrode, a novel glove electrode and standard self-adhesive rectangular electrodes. The glove electrode provides a larger contact area with the skin, thereby stimulating a greater number of nerve fibers. The results show that both electrodes have similar hypoalgesic effects and therefore give the clinician another choice in electrode. PMID:19398378
Impact of universal gowning and gloving on health care worker clothing contamination.
Williams, Calvin; McGraw, Patty; Schneck, Elyse E; LaFae, Anna; Jacob, Jesse T; Moreno, Daniela; Reyes, Katherine; Cubillos, G Fernando; Kett, Daniel H; Estrella, Ronald; Morgan, Daniel J; Harris, Anthony D; Drees, Marci
2015-04-01
To determine whether gowning and gloving for all patient care reduces contamination of healthcare worker (HCW) clothing, compared to usual practice. Cross-sectional surveys. Five study sites were recruited from intensive care units (ICUs) randomized to the intervention arm of the Benefits of Universal Gown and Glove (BUGG) study. All HCWs performing direct patient care in the study ICUs were eligible to participate. Surveys were performed first during the BUGG intervention study period (July-September 2012) with universal gowning/gloving and again after BUGG study conclusion (October-December 2012), with resumption of usual care. During each phase, HCW clothing was sampled at the beginning and near the end of each shift. Cultures were performed using broth enrichment followed by selective media. Acquisition was defined as having a negative clothing culture for samples taken at the beginning of a shift and positive clothing culture at for samples taken at the end of the shift. A total of 348 HCWs participated (21-92 per site), including 179 (51%) during the universal gowning/gloving phase. Overall, 51 (15%) HCWs acquired commonly pathogenic bacteria on their clothing: 13 (7.1%) HCWs acquired bacteria during universal gowning/gloving, and 38 (23%) HCWs acquired bacteria during usual care (odds ratio [OR], 0.3; 95% confidence interval [CI], 0.2-0.6). Pathogens identified included S. aureus (25 species, including 7 methicillin-resistant S. aureus [MRSA]), Enterococcus spp. (25, including 1 vancomycin-resistant Enterococcus [VRE]), Pseudomonas spp. (4), Acinetobacter spp. (4), and Klebsiella (2). Nearly 25% of HCWs practicing usual care (gowning and gloving only for patients with known resistant bacteria) contaminate their clothing during their shift. This contamination was reduced by 70% by gowning and gloving for all patient interactions.
Ineffective hand washing and the contamination of carrots after using a field latrine.
Monaghan, J M; Hutchison, M L
2016-04-01
A study was undertaken to simulate the likely effects of a field worker with poor hygienic practices that had returned to work too soon after recovering from an infection by an enteric pathogen. The studies simulated a variety of hand-washing practices from no washing to washing with soap and water followed by an application of alcohol gel after using a field latrine. The numbers of generic Escherichia coli isolated from workers' hands declined with increasing thoroughness of hand-washing treatments with unwashed hands > water > water and soap > water, soap and alcohol gel. Where gloves were worn the counts obtained for the treatments were significantly reduced, but it was observed that unwashed hands contaminated gloves during the process of putting them on. Hand contamination following the use of a field latrine transferred contamination to carrots. These results suggest that if no gloves are worn it would be best practice to wash hands with water and soap and apply alcohol gel after using a field latrine. Wearing gloves reduced the risk of contaminating handled produce but workers should still wash their hands after using a field latrine before applying gloves. This study shows that inadequate hand hygiene in the field following the use of a field latrine can transfer bacterial contamination to hand-harvested carrots. Where fresh produce crops are to be handled by workers, wearing gloves reduces the risk of contaminating produce but workers should still wash their hands after using a field latrine before applying gloves. If no gloves are worn it would be best practice to wash hands with water and soap and apply alcohol gel after using a field latrine. © 2016 The Society for Applied Microbiology.
Survey of dermal protection in Washington State collision repair industry.
Ceballos, Diana M; Fent, Kenneth W; Whittaker, Stephen G; Gaines, Linda G T; Thomasen, Jennifer M; Flack, Sheila L; Nylander-French, Leena A; Yost, Michael G; Reeb-Whitaker, Carolyn K
2011-09-01
Substantial exposure to isocyanates may occur during spray painting in autobody shops, yet information is lacking on the efficacy of the protective clothing used during spray painting. We investigated the personal and workplace factors associated with painters' dermal protection use during a large-scale exposure assessment study. Survey data indicated that 69% of painters always used gloves, with latex gloves (47%) and nitrile gloves (34%) used most frequently. Among latex glove users, 53% used thin latex (0.05-0.13 mm), 6% used medium latex (0.15-0.20 mm), and 12% used thick latex (> 0.20 mm). Among nitrile glove users, 27% used thin nitrile and 45% used medium nitrile. Sixty-three percent of painters always used coveralls, 44% preferring one particular brand. Although overspray presents an opportunity for dermal exposure to the neck and face, only 19% of painters protected these areas with personal protective equipment. Painters who always used coveralls were more likely to use gloves (odds ratio = 7.9, p = 0.061). Painters who reported ever having smoked cigarettes used gloves (p = 0.05) and coveralls (p = 0.04) more frequently. Painters who sprayed more than 34 clear coat jobs per month used coveralls most frequently (p = 0.038). Exact logistic regressions along with random sample calculations indicated that the survey results were independent of the shops. Because of the small sample size in this study, future research is warranted to corroborate these results. Studying the effectiveness of gloves and coveralls against polyurethane paints and understanding the underlying motivators and preferences for painters and business owners is needed for the development of best practices for the selection and use of dermal protection.
Glove Changing When Handling Money: Observational and Microbiological Analysis.
Basch, Corey H; Wahrman, Miryam Z; Shah, Jay; Guerra, Laura A; MacDonald, Zerlina; Marte, Myladys; Basch, Charles E
2016-04-01
The purpose of this study was to determine the rate of glove changing by mobile food vendors after monetary transactions, and the presence of bacterial contamination on a sample of dollar bills obtained from 25 food vendors near five hospitals in Manhattan, New York City. During 495 monetary transactions observed there were only seven glove changes performed by the workers. Eleven of 34 food workers wore no gloves at all while handling money and food. Nineteen of 25 one-dollar bills collected (76 %) had 400 to 42,000 total bacterial colony-forming units. Colonies were of varied morphology and size. Of these 19 samples, 13 were selected (based on level of growth), and tested for the presence of coliform bacteria, which was found in 10 of the 13 samples. Effective strategies to monitor and increase glove wearing and changing habits of mobile food vendors are needed to reduce risk of foodborne illness.
EVA space suit Evaporative Cooling/Heating Glove System (ECHGS)
NASA Technical Reports Server (NTRS)
Coss, F. A.
1976-01-01
A new astronaut glove, the Evaporative Cooling/Heating Glove System (ECHGS), was designed and developed to allow the handling of objects between -200 F and +200 F. Active heating elements, positioned at each finger pad, provide additional heat to the finger pads from the rest of the finger. A water evaporative cooling system provides cooling by the injection of water to the finger areas and the subsequent direct evaporation to space. Thin, flexible insulation has been developed for the finger areas to limit thermal conductivity. Component and full glove tests have shown that the glove meets and exceeds the requirements to hold a 11/2 inch diameter bar at + or - 200 F for three minutes within comfort limits. The ECHGS is flexible, lightweight and comfortable. Tactility is reasonable and small objects can be identified especially by the fingertips beyond the one half width active elements.
Hong Kai Yap; Kamaldin, Nazir; Jeong Hoon Lim; Nasrallah, Fatima A; Goh, James Cho Hong; Chen-Hua Yeow
2017-06-01
In this paper, we present the design, fabrication and evaluation of a soft wearable robotic glove, which can be used with functional Magnetic Resonance imaging (fMRI) during the hand rehabilitation and task specific training. The soft wearable robotic glove, called MR-Glove, consists of two major components: a) a set of soft pneumatic actuators and b) a glove. The soft pneumatic actuators, which are made of silicone elastomers, generate bending motion and actuate finger joints upon pressurization. The device is MR-compatible as it contains no ferromagnetic materials and operates pneumatically. Our results show that the device did not cause artifacts to fMRI images during hand rehabilitation and task-specific exercises. This study demonstrated the possibility of using fMRI and MR-compatible soft wearable robotic device to study brain activities and motor performances during hand rehabilitation, and to unravel the functional effects of rehabilitation robotics on brain stimulation.
Energy evaluation of protection effectiveness of anti-vibration gloves.
Hermann, Tomasz; Dobry, Marian Witalis
2017-09-01
This article describes an energy method of assessing protection effectiveness of anti-vibration gloves on the human dynamic structure. The study uses dynamic models of the human and the glove specified in Standard No. ISO 10068:2012. The physical models of human-tool systems were developed by combining human physical models with a power tool model. The combined human-tool models were then transformed into mathematical models from which energy models were finally derived. Comparative energy analysis was conducted in the domain of rms powers. The energy models of the human-tool systems were solved using numerical simulation implemented in the MATLAB/Simulink environment. The simulation procedure demonstrated the effectiveness of the anti-vibration glove as a method of protecting human operators of hand-held power tools against vibration. The desirable effect is achieved by lowering the flow of energy in the human-tool system when the anti-vibration glove is employed.
Control of a Glove-Based Grasp Assist Device
NASA Technical Reports Server (NTRS)
Bergelin, Bryan J (Inventor); Ihrke, Chris A. (Inventor); Davis, Donald R. (Inventor); Linn, Douglas Martin (Inventor); Sanders, Adam M (Inventor); Askew, R. Scott (Inventor); Laske, Evan (Inventor); Ensley, Kody (Inventor)
2015-01-01
A grasp assist system includes a glove and sleeve. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. The glove contains a tendon connected at a first end to the digit. The sleeve has an actuator assembly connected to a second end of the tendon and a controller in communication with the sensor. The controller includes a configuration module having selectable operating modes and a processor that calculates a tensile force to apply to the tendon for each of the selectable operating modes to assist the grasping force in a manner that differs for each of the operating modes. A method includes measuring the grasping force, selecting the mode, calculating the tensile force, and applying the tensile force to the tendon using the actuator assembly.
Tactile sensitivity of gloved hands in the cold operation.
Geng, Q; Kuklane, K; Holmér, I
1997-11-01
In this study, tactile sensitivity of gloved hand in the cold operation has been investigated. The relations among physical properties of protective gloves and hand tactile sensitivity and cold protection were also analysed both objectively and subjectively. Subjects with various gloves participated in the experimental study during cold exposure at different ambient temperatures of -12 degrees C and -25 degrees C. Tactual performance was measured using an identification task with various sizes of objects over the percentage of misjudgment. Forearm, hand and finger skin temperatures were also recorded throughout. The experimental data were analysed using analysis of variance (ANOVA) model and the Tukey's multiple range test. The results obtained indicated that the tactual performance was affected both by gloves and by hands/fingers cooling. Effect of object size on the tactile discrimination was significant and the misjudgment increased when similar sizes of objects were identified, especially at -25 degrees C.
Glove-based approach to online signature verification.
Kamel, Nidal S; Sayeed, Shohel; Ellis, Grant A
2008-06-01
Utilizing the multiple degrees of freedom offered by the data glove for each finger and the hand, a novel on-line signature verification system using the Singular Value Decomposition (SVD) numerical tool for signature classification and verification is presented. The proposed technique is based on the Singular Value Decomposition in finding r singular vectors sensing the maximal energy of glove data matrix A, called principal subspace, so the effective dimensionality of A can be reduced. Having modeled the data glove signature through its r-principal subspace, signature authentication is performed by finding the angles between the different subspaces. A demonstration of the data glove is presented as an effective high-bandwidth data entry device for signature verification. This SVD-based signature verification technique is tested and its performance is shown to be able to recognize forgery signatures with a false acceptance rate of less than 1.2%.
Composite Material Hazard Assessment at Crash Sites
2015-01-01
advanced composite materials. All personnel involved in rescue in close crash-site proximity are required to wear self -contained breathing apparatus...close crash-site proximity are required to wear self -contained breathing apparatus, chemical protective clothing, leather gloves, and neoprene...Take extra precaution when handling these materials. Nitrile rubber gloves can be worn underneath the leather gloves to provide chemical hazard
Construct-a-Glove. Science by Design Series.
ERIC Educational Resources Information Center
Pulis, Lee
This book is one of four books in the Science-by-Design Series created by TERC and funded by the National Science Foundation (NSF). It offers high school students a challenging, hands-on opportunity to compare the function and design of many types of handwear from a hockey mitt to a surgical glove, and design and test a glove to their own…
The research of a new data glove based on MARG sensor and magnetic localization technology
NASA Astrophysics Data System (ADS)
Ding, Yi; Gao, Tongyue; Wu, Ye; Zhu, Shihao
2018-04-01
The human hand gesture can record and reproduce the posture and action information of the hand, which is of great significance to people's production and life. This paper has improved the existing data gloves based on micro inertial technology, and integrates the magnetic field localization method into finger gesture measurements. The strap down inertial navigation technology and the magnetic localization technology are combined in this paper to make the advantages complement each other, and a low cost and high degree of freedom of data gloves are put forward to realize the way of data gloves in the past.
Decrease the Number of Glovebox Glove Breaches and Failures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurtle, Jackie C.
2013-12-24
Los Alamos National Laboratory (LANL) is committed to the protection of the workers, public, and environment while performing work and uses gloveboxes as engineered controls to protect workers from exposure to hazardous materials while performing plutonium operations. Glovebox gloves are a weak link in the engineered controls and are a major cause of radiation contamination events which can result in potential worker exposure and localized contamination making operational areas off-limits and putting programmatic work on hold. Each day of lost opportunity at Technical Area (TA) 55, Plutonium Facility (PF) 4 is estimated at $1.36 million. Between July 2011 and Junemore » 2013, TA-55-PF-4 had 65 glovebox glove breaches and failures with an average of 2.7 per month. The glovebox work follows the five step safety process promoted at LANL with a decision diamond interjected for whether or not a glove breach or failure event occurred in the course of performing glovebox work. In the event that no glove breach or failure is detected, there is an additional decision for whether or not contamination is detected. In the event that contamination is detected, the possibility for a glove breach or failure event is revisited.« less
Permeation of Comite through protective gloves.
Zainal, Hanaa; Que Hee, Shane S
2006-09-01
The goal of the study was to assess how protective disposable (Safeskin) and chemical protective (Sol-Vex) nitrile gloves were against Comite emulsifiable concentrate formulation containing propargite (PROP) as active pesticidal ingredient, because there were no explicit recommendations for the gloves that should be worn for hand protection. The glove material was exposed in ASTM-type I-PTC-600 permeation cells at 30.0+/-0.5 degrees C, and gas chromatography-mass spectrometry used for PROP analysis. Aqueous solutions of Comite at 40.4 mg/mL permeated both Safeskin and Sol-Vex nitrile by 8h. Safeskin showed a mean PROP mass permeated of 176+/-27 microg after 8h compared with a mean mass permeated for Sol-Vex of 3.17+/-4.08 microg. Thus, Sol-Vex was about 56 times more protective than Safeskin for an 8-h exposure. However, the kinetics of the permeation revealed that Safeskin can be worn for at least 200 min before disposal. When undiluted Comite challenged both types of nitrile, much faster permeation was observed. Safeskin gloves showed two steady state periods. The first had lag times (t(l)) values of about 1h, although normalized breakthrough times (t(b)) were < 10 min. The second steady state rate (P(s)) was on average four times the rate of the first period, and the second steady state period t(l) was about three times as long as that of the first steady state period, and about the same t(l) as for the aqueous solution. Sol-Vex gloves exposed continuously to undiluted Comite permeated above the normalized breakthrough threshold beyond 2.7h. A risk assessment revealed that the PROP skin permeation rate of 7.1 ng cm(-2)h(-1) was much slower than the first steady state Safeskin glove P(s) of 62,000 ng cm(-2)h(-1). Infrared analysis showed that the glove surfaces were not degraded by the Comite challenge. The chemically protective Sol-Vex gloves protected adequately against undiluted formulation for about 2.7h, whereas they provided protection for nearly 8h when the formulation was diluted with water to the highest concentration for field application. In contrast, the disposable Safeskin gloves did not protect at all for the undiluted formulation, but did for 200 min when the formulation was diluted with water to the highest concentration for spraying.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shinichi Aose; Takafumi Kitajima; Kouji Ogasawara
CPF (Chemical Processing Facility) was constructed at Nuclear Fuel Cycle Engineering Laboratories of JAEA (Japan Atomic Energy Agency) in 1980 as a basic research field where spent fuel pins from fast reactor (FR) and high level liquid waste can be dealt with. The renovation consists of remodeling of the CA-3 cell and the laboratory A, installation of globe boxes, hoods and analytical equipments to the laboratory C and the analytical laboratory. Also maintenance equipments in the CA-5 cell which had been out of order were repaired. The CA-3 cell is the main cell in which important equipments such as amore » dissolver, a clarifier and extractors are installed for carrying out the hot test using the irradiated FR fuel. Since the CPF had specialized originally in the research function for the Purex process, it was desired to execute the research and development of such new, various reprocessing processes. Formerly, equipments were arranged in wide space and connected with not only each other but also with utility supply system mainly by fixed stainless steel pipes. It caused shortage of operation space in flexibility for basic experimental study. Old equipments in the CA-3 cell including vessels and pipes were removed after successful decontamination, and new equipments were installed conformably to the new design. For the purpose of easy installation and rearranging the experimental equipments, equipments are basically connected by flexible pipes. Since dissolver is able to be easily replaced, various dissolution experiments is conducted. Insoluble residue generated by dissolution of spent fuel is clarified by centrifugal. This small apparatus is effective to space-saving. Mini mixer settlers or centrifugal contactors are put on to the prescribed limited space in front of the backside wall. Fresh reagents such as solvent, scrubbing and stripping solution are continuously fed from the laboratory A to the extractor by the reagent supply system with semi-automatic observation system. The in-cell crane in CA-5 was renovated to increase driving efficiency. At the renovation for the in-cell crane, full scale mockup test and 3D simulation test had been executed in advance. After the renovation, hot tests in the CPF had been resumed from JFY 2002. New equipments such as dissolver, extractor, electrolytic device, etc. were installed in CA-3 conformably to the new design laid out in order to ensure the function and space. Glove boxes in the analysis laboratory were renewed in order to let it have flexibility from the viewpoint of conducting basic experiments (ex. U crystallization). Glove boxes and hoods were newly installed in the laboratory A for basic research and analysis, especially on MA chemistries. One laboratory (the laboratory C) was established to research about dry reprocessing. The renovation of the CPF has been executed in order to contribute to the development on the advanced fast reactor fuel cycle system, which will give us many sort of technical subject and experimental theme to be solved in the 2. Generation of the CPF.« less
Wilke, A; Skudlik, C; Sonsmann, F K
2018-05-02
The dermatologist's procedure is a pivotal tool for early recognition of occupational contact dermatitis (OCD), for reporting OCD cases to the statutory accident insurance and for treating the diseases. The employer is in charge of implementing skin protection measures at the workplace. However, in terms of an individual prevention approach it may be necessary to propose targeted skin protection recommendations in specific patient cases. The patient's own skin protection behavior significantly contributes to regenerating and maintaining healthy skin. This behavior includes the use of occupational skin products, and in particular the correct use of appropriately selected protective gloves. Protective gloves are the most important personal protective measure in the prevention of OCD. Prevention services, occupational health and safety specialists, occupational physicians and centers specialized in occupational dermatology can support the identification of suitable protective measures. Nowadays, suitable protective gloves exist for (almost) every occupational activity and exposure. However, improper use in practice can become a risk factor by itself for the skin (e. g., incorrectly used gloves). Therefore, it is of utmost importance to identify application errors, to educate patients in terms of skin protection and to motivate them to perform an appropriate skin protection behavior. With particular focus on protective gloves, this article gives an overview of various types, materials and potentially glove-related allergens, presents strategies for reducing occlusion effects and discusses some typical application errors and solutions.
Weistenhöfer, Wobbeke; Uter, Wolfgang; Drexler, Hans
2017-01-01
Wearing of occlusive gloves during the whole working shift is considered a risk factor for developing hand eczema, similar to wet work. Moreover, the increased hydration due to glove occlusion may lead to brittle nails. Two hundred and seventy clean room workers, wearing occlusive gloves for prolonged periods, and 135 administrative employees not using gloves were investigated. This included a dermatological examination of the nails and the hands, using the Hand Eczema ScoRe for Occupational Screening (HEROS), measurement of transepidermal water loss (TEWL), and a standardized interview. Of the clean room workers, 39%, mainly women, reported nail problems, mostly brittle nails with onychoschisis. Skin score values showed no significant differences between HEROS values of both groups. TEWL values of exposed subjects were similar to TEWL values of controls 40 min after taking off the occlusive gloves. In a multiple linear regression analysis, male gender and duration of employment in the clean room were associated with a significant increase in TEWL values. The effect of occlusion on TEWL seems to be predominantly transient and not be indicative of a damaged skin barrier. This study confirmed the results of a previous investigation showing no serious adverse effect of wearing of occlusive gloves on skin condition without exposure to additional hazardous substances. However, occlusion leads to softened nails prone to mechanical injury. Therefore, specific prevention instructions are required to pay attention to this side effect of occlusion.
Liss, G M; Tarlo, S M
2001-10-01
Exposure to natural rubber latex (NRL) has been recognized as a cause of occupational asthma (OA), especially among health care workers (HCWs) associated with use of gloves. Little or no population-based data are available which chart the changes over time in the number of cases of OA as this problem was increasingly recognized and then interventions instituted. We obtained the numbers of allowed asthma claims with exposure to latex by year in the province of Ontario, Canada from the Ontario Workplace Safety and Insurance Board; details of the cases from the largest teaching hospital were reviewed. Interventions included: (1) in 1996, the Board recommended in its focus for accommodation of sensitized workers, the reduction of aerosols of latex proteins and that hospital facilities use powder-free, low-protein or nonlatex gloves; and (2) hospitals instituted latex policies and glove changes at various dates. For example, at the largest teaching hospital, interventions included education and voluntary medical surveillance in 1994; substitution of low protein, "powder-free" NRL gloves for non-sterile powdered gloves in 1995; and replacement of powdered sterile NRL gloves by lower protein, "powder-free" NRL gloves in 1997. Through 1999, there were 60 allowed claims for asthma in Ontario with exposure to latex; of these 49 (82%) were among HCWs. The number of claims among HCWs changed from 0 to 2 per year up to 1990; increased to 7 to 11 per year between 1991-1994; and declined to 3 per year in 1995-1996 and 1 to 2 per year in 1997-1999. Of the ten institutions having two or more OA latex claims, all claims occurred in 1996 or earlier at 8 (80%). At the largest hospital, there were five accepted claims with year of diagnosis in 1993 (1 case), 1994 (3 cases), and 1995 (1 case). These findings suggest that, despite the effect of increasing recognition, the introduction of gloves with reduced powder and/or protein, as well as other interventions have been associated temporally with declines in the number of cases of latex OA. Copyright 2001 Wiley-Liss, Inc.
Henriks-Eckerman, Maj-Len; Mäkelä, Erja A; Suuronen, Katri
2015-10-01
Efficient, comfortable, yet affordable personal protective equipment (PPE) is needed to decrease the high incidence of allergic contact dermatitis arising from epoxy resin systems (ERSs) in industrial countries. The aim of this study was to find affordable, user-friendly glove and clothing materials that provide adequate skin protection against splashes and during the short contact with ERS that often occurs before full cure. We studied the penetration of epoxy resin and diamine hardeners through 12 glove or clothing materials using a newly developed test method. The tests were carried out with two ERS test mixtures that had a high content of epoxy resin and frequently used diamine hardeners of different molar masses. A drop (50 µl) of test mixture was placed on the outer surface of the glove/clothing material, which had a piece of Fixomull tape or Harmony protection sheet attached to the inner surface as the collection medium. The test times were 10 and 30 min. The collecting material was removed after the test was finished and immersed into acetone. The amounts of diglycidyl ether of bisphenol A (DGEBA), isophorone diamine (IPDA), and m-xylylenediamine (XDA) in the acetone solution were determined by gas chromatography with mass spectrometric detection. The limit for acceptable penetration of XDA, IPDA, and DGEBA through glove materials was set at 2 µg cm(-2). Penetration through the glove materials was 1.4 µg cm(-2) or less. The three tested chemical protective gloves showed no detectable penetration (<0.5 µg cm(-2)). Several affordable glove and clothing materials were found to provide adequate protection during short contact with ERS, in the form of, for example, disposable gloves or clothing materials suitable for aprons and as additional protective layers on the most exposed parts of clothing, such as the front of the legs and thighs and under the forearms. Every ERS combination in use should be tested separately to find the best skin protection material, and this can be done by using this simple test method. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Glove perforation rate in open lung surgery.
Hollaus, P H; Lax, F; Janakiev, D; Wurnig, P N; Pridun, N S
1999-04-01
In open lung surgery the surgical access is encircled by the ribs, which should result in a high glove perforation rate compared with other surgical specialities. Prospectively the surgeon, first and second assistant and the scrub nurse wore double standard latex gloves during 100 thoracotomies. Parameters recorded were: procedure performed, number of perforations, localization of perforation, the seniority of the surgeon, manoeuvre performed at the moment of perforation, immediate cause of perforation, operation time, performance of rib resection during thoracotomy and time of occurrence of the first three perforations. One thousand, six hundred and seventy-three gloves (902 outer, 771 inner) were tested. In 78 operations perforations occurred. There were 150 outer glove perforations (8.9%, 0-8, mean 1.23), 19 inner glove perforations (1.13%, 0-2, mean 0.19). Cutaneous blood exposure was prevented in 78% of all operations and in 87% of all perforations. The perforation rate for the surgeon, the scrub nurse, the first and the second assistant were 61.2, 40.4, 9.7 and 3.1% of all operations, respectively. Rib resection and a duration of more than 2 h resulted in a significant rise of glove perforation rate (P<0.05). The personal experience of the surgeon and the type of operation did not correlate with glove perforation. The immediate cause leading to perforation was named in only 17 cases (13.7%) and comprised contact with bone (seven), a needle stitch (seven) and a production flaw (three). Leaks were localized mostly on the first finger (18%),second finger, (39%) palm and dorsum of the hand (16%). The average occurrence of all first perforations was 38.7 min (range 3-190) after the beginning of surgery, the second after 63.2 min (range 10-195). Fifty-four first perforations (50.5%) were found during the first 30 min of the operation. The reported perforation rate of 78% lies in the highest range of reported perforation rates in different surgical specialities. Double gloving effectively prevented cutaneous blood exposure and thus should become a routine for the thoracic surgeon to prevent transmission of infectious diseases from the patient to the surgeon.
NASA Technical Reports Server (NTRS)
Wingard, Doug
2009-01-01
The Advanced Crew Escape Suit (ACES) is a pressurized suit normally worn by astronauts during launch and landing phases of Space Shuttle operations. In 2008, a large tear (0.5 -1 in. long, between the pinky and ring finger) in the ACES left-hand glove made of neoprene latex rubber was found during training for Shuttle flight STS-124. An investigation to help determine the cause(s) of the glove tear was headed by the NASA Johnson Space Center (JSC) in Houston, Texas. Efforts at JSC to reproduce the actual glove tear pattern by cutting/tearing or rupturing were unsuccessful. Chemical and material property data from JSC such as GC-MS, FTIR, DSC and TGA mostly showed little differences between samples from the torn and control gloves. One possible cause for the glove tear could be a wedding ring/band worn by a male astronaut. Even with a smooth edge, such a ring could scratch the material and initiate the tear observed in the left-hand glove. A decision was later made by JSC to not allow the wearing of such a ring during training or actual flight. Another possible cause for the ACES glove tear is crystallinity induced by strain in the neoprene rubber over a long period of time and use. Neoprene is one several elastomeric materials known to be susceptible to crystallization, and such a process is accelerated with exposure of the material to cold temperatures plus strain. When the temperature is lowered below room temperature, researchers have shown that neoprene crystallization may be maintained at temperatures as high as 45-50 F, with a maximum crystallization rate near 20-25 F (1). A convenient conditioning temperature for inducing neoprene crystallization is a typical freezer that is held near 0 F. For work at the NASA Marshall Space Flight Center (MSFC), samples were cut from several areas/locations (pinky/ring finger crotch, index finger and palm) on each of two pairs of unstrained ACES gloves for DSC and DMA thermal analysis testing. The samples were conditioned in a freezer for various times up to about 14 days. Some rectangular conditioned samples were unstrained, while most were subjected to strains up to 250% with the aid of two slotted aluminum blocks and two aluminum clamps per sample. Trends were observed to correlate DSC data (heat of fusion) and DMA data (linear CTE and stress for iso-strain testing) with: (a) sample location on each glove; and (b) level of strain during conditioning. Control samples cut as is from each glove location were also tested by DSC and DMA.
Evaluating an immersive virtual environment prototyping and simulation system
NASA Astrophysics Data System (ADS)
Nemire, Kenneth
1997-05-01
An immersive virtual environment (IVE) modeling and simulation tool is being developed for designing advanced weapon and training systems. One unique feature of the tool is that the design, and not just visualization of the design is accomplished with the IVE tool. Acceptance of IVE tools requires comparisons with current commercial applications. In this pilot study, expert users of a popular desktop 3D graphics application performed identical modeling and simulation tasks using both the desktop and IVE applications. The IVE tool consisted of a head-mounted display, 3D spatialized sound, spatial trackers on head and hands, instrumented gloves, and a simulated speech recognition system. The results are preliminary because performance from only four users has been examined. When using the IVE system, users completed the tasks to criteria in less time than when using the desktop application. Subjective ratings of the visual displays in each system were similar. Ratings for the desktop controls were higher than for the IVE controls. Ratings of immersion and user enjoyment were higher for the IVE than for the desktop application. These results are particular remarkable because participants had used the desktop application regularly for three to five years and the prototype IVE tool for only three to six hours.
Ding, Li; Han, Long-zhu; Yang, Chun-xin; Yang, Feng; Yuan, Xiu-gan
2005-02-01
To observe the effects of active heating system for spacesuit gloves on extravehicular working performance. After analyzing the factors with gloves influence on the working performance, the effects of active heating system for gloves were studied experimentally with aspects to fatigue, hand strength, dexterity and tactile sensing. 1) Heating-system had not influence to grip; 2) Heating-system had 17% influence to fatigue except specific person; 3) Nut assembly and nipping pin showed that heating-system had little influence to dexterity; 4) Apperceiving shape of object and two-point distance showed heating-system had little influence to tactility. The active heating method is rational and has little influence on working performance.
NASA Technical Reports Server (NTRS)
1995-01-01
A mock-up of the stainless-steel Pegasus Hypersonic Experiment (PHYSX) Projects experimental 'glove' undergoes hot-loads tests at NASA's Dryden Flight Research Center, Edwards, California. The thermal ground test simulates heats and pressures the wing glove will experience at hypersonic speeds. Quartz heat lamps subject this model of a Pegasus booster rocket's right wing glove to the extreme heats it will experience at speeds approaching Mach 8. The glove has a highly reflective surface, underneath which are hundreds of temperature and pressure sensors that will send hypersonic flight data to ground tracking facilities during the experimental flight. Pegasus is an air-launched space booster produced by Orbital Sciences Corporation and Hercules Aerospace Company (initially; later, Alliant Tech Systems) to provide small satellite users with a cost-effective, flexible, and reliable method for placing payloads into low earth orbit. Pegasus has been used to launch a number of satellites and the PHYSX experiment. That experiment consisted of a smooth glove installed on the first-stage delta wing of the Pegasus. The glove was used to gather data at speeds of up to Mach 8 and at altitudes approaching 200,000 feet. The flight took place on October 22, 1998. The PHYSX experiment focused on determining where boundary-layer transition occurs on the glove and on identifying the flow mechanism causing transition over the glove. Data from this flight-research effort included temperature, heat transfer, pressure measurements, airflow, and trajectory reconstruction. Hypersonic flight-research programs are an approach to validate design methods for hypersonic vehicles (those that fly more than five times the speed of sound, or Mach 5). Dryden Flight Research Center, Edwards, California, provided overall management of the glove experiment, glove design, and buildup. Dryden also was responsible for conducting the flight tests. Langley Research Center, Hampton, Virginia, was responsible for the design of the aerodynamic glove as well as development of sensor and instrumentation systems for the glove. Other participating NASA centers included Ames Research Center, Mountain View, California; Goddard Space Flight Center, Greenbelt, Maryland; and Kennedy Space Center, Florida. Orbital Sciences Corporation, Dulles, Virginia, is the manufacturer of the Pegasus vehicle, while Vandenberg Air Force Base served as a pre-launch assembly facility for the launch that included the PHYSX experiment. NASA used data from Pegasus launches to obtain considerable data on aerodynamics. By conducting experiments in a piggyback mode on Pegasus, some critical and secondary design and development issues were addressed at hypersonic speeds. The vehicle was also used to develop hypersonic flight instrumentation and test techniques. NASA's B-52 carrier-launch vehicle was used to get the Pegasus airborne during six launches from 1990 to 1994. Thereafter, an Orbital Sciences L-1011 aircraft launched the Pegasus. The Pegasus launch vehicle itself has a 400- to 600-pound payload capacity in a 61-cubic-foot payload space at the front of the vehicle. The vehicle is capable of placing a payload into low earth orbit. This vehicle is 49 feet long and 50 inches in diameter. It has a wing span of 22 feet. (There is also a Pegasus XL vehicle that was introduced in 1994. Dryden has never launched one of these vehicles, but they have greater thrust and are 56 feet long.)
Hand Rehabilitation Learning System With an Exoskeleton Robotic Glove.
Ma, Zhou; Ben-Tzvi, Pinhas; Danoff, Jerome
2016-12-01
This paper presents a hand rehabilitation learning system, the SAFE Glove, a device that can be utilized to enhance the rehabilitation of subjects with disabilities. This system is able to learn fingertip motion and force for grasping different objects and then record and analyze the common movements of hand function including grip and release patterns. The glove is then able to reproduce these movement patterns in playback fashion to assist a weakened hand to accomplish these movements, or to modulate the assistive level based on the user's or therapist's intent for the purpose of hand rehabilitation therapy. Preliminary data have been collected from healthy hands. To demonstrate the glove's ability to manipulate the hand, the glove has been fitted on a wooden hand and the grasping of various objects was performed. To further prove that hands can be safely driven by this haptic mechanism, force sensor readings placed between each finger and the mechanism are plotted. These experimental results demonstrate the potential of the proposed system in rehabilitation therapy.
The Effects of Extravehicular Activity (EVA) Glove Pressure on Tactility
NASA Technical Reports Server (NTRS)
Thompson, Shelby; Miranda, Mesloh; England, Scott; Benson, Elizabeth; Rajulu, Sudhakar
2010-01-01
The purpose of the current study was to quantify finger tactility, while wearing a Phase VI Extravehicular Activity (EVA) glove. Subjects were fully suited in an Extravehicular Mobility Unit (EMU) suit. Data was collected under three conditions: bare-handed, gloved at 0 psi, and gloved at 4.3 psi. In order to test tactility, a series of 30 tactile stimuli (bumps) were created that varied in both height and width. With the hand obscured, subjects applied pressure to each bump until detected tactilely. The amount of force needed to detect each bump was recorded using load cells located under a force-plate. The amount of force needed to detect a bump was positively related to width, but inversely related to height. In addition, as the psi of the glove increased, more force was needed to detect the bump. In terms of application, it was possible to determine the optimal width and height a bump needs to be for a specific amount of force applied for tactility.
Instrumented Glove Measures Positions Of Fingers
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr.
1993-01-01
Glove instrumented with flat membrane potentiometers to obtain crude measurements of relative positions of fingers. Resistance of each potentiometer varies with position of associated finger; translator circuit connected to each potentiometer converts analog reading to 1 of 10 digital levels. Digitized outputs from all fingers fed to indicating, recording, and/or data-processing equipment. Gloves and circuits intended for use in biomedical research, training in critical manual tasks, and other specialized applications.
NASA Technical Reports Server (NTRS)
1976-01-01
Comfort Products, Inc. was responsible for the cold weather glove and thermal boots, adapted from a spacesuit design that kept astronauts warm or cool in the temperature extremes of the Apollo Moon Mission. Gloves and boots are thermally heated. Batteries are worn inside wrist of glove or sealed in sole of skiboot and are rechargeable hundreds of times. They operate flexible resistance circuit which is turned on periodically when wearer wants to be warm.