A framework for automatic creation of gold-standard rigid 3D-2D registration datasets.
Madan, Hennadii; Pernuš, Franjo; Likar, Boštjan; Špiclin, Žiga
2017-02-01
Advanced image-guided medical procedures incorporate 2D intra-interventional information into pre-interventional 3D image and plan of the procedure through 3D/2D image registration (32R). To enter clinical use, and even for publication purposes, novel and existing 32R methods have to be rigorously validated. The performance of a 32R method can be estimated by comparing it to an accurate reference or gold standard method (usually based on fiducial markers) on the same set of images (gold standard dataset). Objective validation and comparison of methods are possible only if evaluation methodology is standardized, and the gold standard dataset is made publicly available. Currently, very few such datasets exist and only one contains images of multiple patients acquired during a procedure. To encourage the creation of gold standard 32R datasets, we propose an automatic framework. The framework is based on rigid registration of fiducial markers. The main novelty is spatial grouping of fiducial markers on the carrier device, which enables automatic marker localization and identification across the 3D and 2D images. The proposed framework was demonstrated on clinical angiograms of 20 patients. Rigid 32R computed by the framework was more accurate than that obtained manually, with the respective target registration error below 0.027 mm compared to 0.040 mm. The framework is applicable for gold standard setup on any rigid anatomy, provided that the acquired images contain spatially grouped fiducial markers. The gold standard datasets and software will be made publicly available.
Jha, Abhinav K.; Mena, Esther; Caffo, Brian; Ashrafinia, Saeed; Rahmim, Arman; Frey, Eric; Subramaniam, Rathan M.
2017-01-01
Abstract. Recently, a class of no-gold-standard (NGS) techniques have been proposed to evaluate quantitative imaging methods using patient data. These techniques provide figures of merit (FoMs) quantifying the precision of the estimated quantitative value without requiring repeated measurements and without requiring a gold standard. However, applying these techniques to patient data presents several practical difficulties including assessing the underlying assumptions, accounting for patient-sampling-related uncertainty, and assessing the reliability of the estimated FoMs. To address these issues, we propose statistical tests that provide confidence in the underlying assumptions and in the reliability of the estimated FoMs. Furthermore, the NGS technique is integrated within a bootstrap-based methodology to account for patient-sampling-related uncertainty. The developed NGS framework was applied to evaluate four methods for segmenting lesions from F-Fluoro-2-deoxyglucose positron emission tomography images of patients with head-and-neck cancer on the task of precisely measuring the metabolic tumor volume. The NGS technique consistently predicted the same segmentation method as the most precise method. The proposed framework provided confidence in these results, even when gold-standard data were not available. The bootstrap-based methodology indicated improved performance of the NGS technique with larger numbers of patient studies, as was expected, and yielded consistent results as long as data from more than 80 lesions were available for the analysis. PMID:28331883
NCI Updates Tobacco Policies Following Re-accreditation | Poster
This year, NCI was re-accredited as one of nearly 200 CEO Cancer Gold Standard employers across the United States. According to its website, “the CEO Cancer Gold Standard provides a framework for employers to have a healthier workplace by focusing on cancer risk reduction, early detection, and access to clinical trials and high-quality care.” As part of this re-accreditation,
Making and Measuring the California History Standards
ERIC Educational Resources Information Center
Fogo, Bradley
2011-01-01
The California history and social science standards-based reform has been touted as the "gold standard" for state history curricula. But the standards, framework, and tests that constitute this reform provide inconsistent and contradictory criteria for teaching and assessing history and social science. An examination of the political…
NCI Updates Tobacco Policies Following Re-accreditation | Poster
This year, NCI was re-accredited as one of nearly 200 CEO Cancer Gold Standard employers across the United States. According to its website, “the CEO Cancer Gold Standard provides a framework for employers to have a healthier workplace by focusing on cancer risk reduction, early detection, and access to clinical trials and high-quality care.” As part of this re-accreditation, NCI has updated its Tobacco-Free Policy. Part of this policy includes posting signs around campus reminding visitors and staff that NCI’s campus is tobacco-free. Therefore, the use of all tobacco products is prohibited. This includes cigarettes, cigars, pipes, e-cigarettes, and smokeless tobacco.
USDA-ARS?s Scientific Manuscript database
Prokaryotic taxonomy is the underpinning of microbiology, providing a framework for the proper identification and naming of organisms. The 'gold standard' of bacterial species delineation is the overall genome similarity as determined by DNA-DNA hybridization (DDH), a technically rigorous yet someti...
Luo, Sheng; Su, Xiao; DeSantis, Stacia M; Huang, Xuelin; Yi, Min; Hunt, Kelly K
2014-07-10
Breast cancer patients after breast conservation therapy often develop ipsilateral breast tumor relapse (IBTR), whose classification (true local recurrence versus new ipsilateral primary tumor) is subject to error, and there is no available gold standard. Some patients may die because of breast cancer before IBTR develops. Because this terminal event may be related to the individual patient's unobserved disease status and time to IBTR, the terminal mechanism is non-ignorable. This article presents a joint analysis framework to model the binomial regression with misclassified binary outcome and the correlated time to IBTR, subject to a dependent terminal event and in the absence of a gold standard. Shared random effects are used to link together two survival times. The proposed approach is evaluated by a simulation study and is applied to a breast cancer data set consisting of 4477 breast cancer patients. The proposed joint model can be conveniently fit using adaptive Gaussian quadrature tools implemented in SAS 9.3 (SAS Institute Inc., Cary, NC, USA) procedure NLMIXED. Copyright © 2014 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Feng, Steve; Woo, Minjae; Chandramouli, Krithika; Ozcan, Aydogan
2015-03-01
Over the past decade, crowd-sourcing complex image analysis tasks to a human crowd has emerged as an alternative to energy-inefficient and difficult-to-implement computational approaches. Following this trend, we have developed a mathematical framework for statistically combining human crowd-sourcing of biomedical image analysis and diagnosis through games. Using a web-based smart game (BioGames), we demonstrated this platform's effectiveness for telediagnosis of malaria from microscopic images of individual red blood cells (RBCs). After public release in early 2012 (http://biogames.ee.ucla.edu), more than 3000 gamers (experts and non-experts) used this BioGames platform to diagnose over 2800 distinct RBC images, marking them as positive (infected) or negative (non-infected). Furthermore, we asked expert diagnosticians to tag the same set of cells with labels of positive, negative, or questionable (insufficient information for a reliable diagnosis) and statistically combined their decisions to generate a gold standard malaria image library. Our framework utilized minimally trained gamers' diagnoses to generate a set of statistical labels with an accuracy that is within 98% of our gold standard image library, demonstrating the "wisdom of the crowd". Using the same image library, we have recently launched a web-based malaria training and educational game allowing diagnosticians to compare their performance with their peers. After diagnosing a set of ~500 cells per game, diagnosticians can compare their quantified scores against a leaderboard and view their misdiagnosed cells. Using this platform, we aim to expand our gold standard library with new RBC images and provide a quantified digital tool for measuring and improving diagnostician training globally.
Systematic Observation of Early Adolescents in Educational Settings: The Good, the Bad, and the Ugly
ERIC Educational Resources Information Center
Gregory, Anne; Mikami, Amori Yee
2015-01-01
The growing use of systematic, empirically tested observational frameworks in school-based research is crucial for increasing the replicability and generalizability of findings across settings. That said, observations are often mistakenly assumed to be the "gold standard" assessment, without more nuanced discussions about the best uses…
Parameter estimation in Cox models with missing failure indicators and the OPPERA study.
Brownstein, Naomi C; Cai, Jianwen; Slade, Gary D; Bair, Eric
2015-12-30
In a prospective cohort study, examining all participants for incidence of the condition of interest may be prohibitively expensive. For example, the "gold standard" for diagnosing temporomandibular disorder (TMD) is a physical examination by a trained clinician. In large studies, examining all participants in this manner is infeasible. Instead, it is common to use questionnaires to screen for incidence of TMD and perform the "gold standard" examination only on participants who screen positively. Unfortunately, some participants may leave the study before receiving the "gold standard" examination. Within the framework of survival analysis, this results in missing failure indicators. Motivated by the Orofacial Pain: Prospective Evaluation and Risk Assessment (OPPERA) study, a large cohort study of TMD, we propose a method for parameter estimation in survival models with missing failure indicators. We estimate the probability of being an incident case for those lacking a "gold standard" examination using logistic regression. These estimated probabilities are used to generate multiple imputations of case status for each missing examination that are combined with observed data in appropriate regression models. The variance introduced by the procedure is estimated using multiple imputation. The method can be used to estimate both regression coefficients in Cox proportional hazard models as well as incidence rates using Poisson regression. We simulate data with missing failure indicators and show that our method performs as well as or better than competing methods. Finally, we apply the proposed method to data from the OPPERA study. Copyright © 2015 John Wiley & Sons, Ltd.
Strategic Framing Study Circles: Toward a Gold Standard of Framing Pedagogy
ERIC Educational Resources Information Center
Feinberg, Jane
2009-01-01
This article explains how communities of practice have been developed as part of FrameWorks' field-building efforts. Strategic Framing Study Circles, as they are known, have been conducted with four statewide coalitions, one group of national organizations, and an emerging regional coalition. The goal of each community of practice is to build…
A Theoretical Framework for Human and Veterinary Medical Ethics Education
ERIC Educational Resources Information Center
Magalhães-Sant'Ana, Manuel
2016-01-01
In their practice, physicians and veterinarians need to resort to an array of ethical competences. As a teaching topic, however, there is no accepted gold standard for human medical ethics, and veterinary medical ethics is not yet well established. This paper provides a reflection on the underlying aims of human and veterinary medical ethics…
ERIC Educational Resources Information Center
Chatterji, Madhabi; Kwon, Young Ae; Sng, Clarice
2006-01-01
The No Child Left Behind (NCLB) Act of 2001 requires that public schools adopt research-supported programs and practices, with a strong recommendation for randomized controlled trials (RCTs) as the "gold standard" for scientific rigor in empirical research. Within that policy framework, this paper compares the relative utility of…
Jones, Paul W; Nadeau, Gilbert; Small, Mark; Adamek, Lukasz
2014-01-01
GOLD proposed a COPD assessment framework focussed on symptoms measured by the COPD Assessment Test™ (CAT) or the mMRC and on exacerbation risk based on poor lung function (FEV1 <50%) or a history of ≥2 exacerbations in the previous year. This analysis examined the characteristics of COPD patients recruited from routine clinical settings and classified using the GOLD framework. 1041 European COPD patients (38.5% from primary care) from the Adelphi Respiratory Disease Specific Programme with information on CAT, mMRC, spirometry and exacerbation history in the previous year were analysed. Their mean age was 64.9 ± 9.9 years and mean FEV1 was 62.5 ± 17.8% predicted; 80% were in GOLD 2 spirometric grade or milder. CAT and mMRC cut points identified different groups of patients; using CAT, the composition was: Group A 9.3%, Group B 48.5%, Group C 0.7% and Group D 41.5%. 80% were classified as high risk based on exacerbation history and 25% of patients in a low risk category (GOLD A and B) had 1 exacerbation in the previous year. The incidence of diabetes, hypertension and hyperlipidaemia rose with worsening GOLD group (all p < 0.0001); diabetes GOLD A 4%, GOLD B 16%, GOLD D 29%; hypertension GOLD A 38%, GOLD B 55%, GOLD D 65%; hyperlipidaemia GOLD A 13%, GOLD B 30%, GOLD D 37%. In patients seen in routine clinical settings, 25% of GOLD low risk patients had one exacerbation per year and the incidence of cardio-vascular and metabolic diseases increases with worsening GOLD group. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.
Karch, Annika; Koch, Armin; Zapf, Antonia; Zerr, Inga; Karch, André
2016-10-01
To investigate how choice of gold standard biases estimates of sensitivity and specificity in studies reassessing the diagnostic accuracy of biomarkers that are already part of a lifetime composite gold standard (CGS). We performed a simulation study based on the real-life example of the biomarker "protein 14-3-3" used for diagnosing Creutzfeldt-Jakob disease. Three different types of gold standard were compared: perfect gold standard "autopsy" (available in a small fraction only; prone to partial verification bias), lifetime CGS (including the biomarker under investigation; prone to incorporation bias), and "best available" gold standard (autopsy if available, otherwise CGS). Sensitivity was unbiased when comparing 14-3-3 with autopsy but overestimated when using CGS or "best available" gold standard. Specificity of 14-3-3 was underestimated in scenarios comparing 14-3-3 with autopsy (up to 24%). In contrast, overestimation (up to 20%) was observed for specificity compared with CGS; this could be reduced to 0-10% when using the "best available" gold standard. Choice of gold standard affects considerably estimates of diagnostic accuracy. Using the "best available" gold standard (autopsy where available, otherwise CGS) leads to valid estimates of specificity, whereas sensitivity is estimated best when tested against autopsy alone. Copyright © 2016 Elsevier Inc. All rights reserved.
Ortorp, Anders; Jemt, Torsten
2006-01-01
Long-term follow-up studies for more than 5 years are not available on laser-welded titanium frameworks. To report and compare 10-year data on implant-supported prostheses in the edentulous mandible provided with laser-welded titanium frameworks and conventional gold alloy frameworks. Altogether, 155 patients were consecutively treated with prostheses at abutment level with two generations of fixed laser-welded titanium frameworks (test groups). A control group of 53 randomly selected patients with conventional gold alloy castings was used for comparison. Clinical and radiographic 10-year data were collected for the three groups. All patients followed-up for 10 years (n=112) still had fixed prostheses in the mandible (cumulative success rate [CSR] 100%). The overall 10-year cumulative success rate (CSR) was 92.8 and 100.0% for titanium and gold alloy frameworks, respectively. Ten-year implant cumulative survival rate (CSR) was 99.4 and 99.6% for the test and control groups, respectively. Average 10-year bone loss was 0.56 (SD 0.45) mm for the titanium group and 0.77 (SD 0.36) mm for the control group (p < 0.05). The most common complications for titanium frameworks were resin or veneer fractures, soft tissue inflammation, and fractures (12.9%) of the metal frame. Loose and fractured implant screw components were below 3%. Excellent overall long-term results with 100% CSR could be achieved with the present treatment modality. Fractures of the metal frames and remade prostheses were more common for the laser-welded titanium frameworks, and the first generation of titanium frameworks worked poorly when compared with gold alloy frameworks during 10 years (p < 0.05). However, on average more bone loss was observed for implants supporting gold alloy frameworks during 10 years. The reasons for this difference are not clear.
Establishment of gold-quartz standard GQS-1
Millard, Hugh T.; Marinenko, John; McLane, John E.
1969-01-01
A homogeneous gold-quartz standard, GQS-1, was prepared from a heterogeneous gold-bearing quartz by chemical treatment. The concentration of gold in GQS-1 was determined by both instrumental neutron activation analysis and radioisotope dilution analysis to be 2.61?0.10 parts per million. Analysis of 10 samples of the standard by both instrumental neutron activation analysis and radioisotope dilution analysis failed to reveal heterogeneity within the standard. The precision of the analytical methods, expressed as standard error, was approximately 0.1 part per million. The analytical data were also used to estimate the average size of gold particles. The chemical treatment apparently reduced the average diameter of the gold particles by at least an order of magnitude and increased the concentration of gold grains by a factor of at least 4,000.
Automatic Structural Parcellation of Mouse Brain MRI Using Multi-Atlas Label Fusion
Ma, Da; Cardoso, Manuel J.; Modat, Marc; Powell, Nick; Wells, Jack; Holmes, Holly; Wiseman, Frances; Tybulewicz, Victor; Fisher, Elizabeth; Lythgoe, Mark F.; Ourselin, Sébastien
2014-01-01
Multi-atlas segmentation propagation has evolved quickly in recent years, becoming a state-of-the-art methodology for automatic parcellation of structural images. However, few studies have applied these methods to preclinical research. In this study, we present a fully automatic framework for mouse brain MRI structural parcellation using multi-atlas segmentation propagation. The framework adopts the similarity and truth estimation for propagated segmentations (STEPS) algorithm, which utilises a locally normalised cross correlation similarity metric for atlas selection and an extended simultaneous truth and performance level estimation (STAPLE) framework for multi-label fusion. The segmentation accuracy of the multi-atlas framework was evaluated using publicly available mouse brain atlas databases with pre-segmented manually labelled anatomical structures as the gold standard, and optimised parameters were obtained for the STEPS algorithm in the label fusion to achieve the best segmentation accuracy. We showed that our multi-atlas framework resulted in significantly higher segmentation accuracy compared to single-atlas based segmentation, as well as to the original STAPLE framework. PMID:24475148
Sun, Raymond Wai-Yin; Zhang, Ming; Li, Dan; Li, Mian; Wong, Alice Sze-Tsai
2016-10-01
An anti-cancer active gold(III) pyrrolidinedithiocarbamato complex [(PDTC)Au III Cl 2 ] (1) has been synthesized and characterized by means of X-ray crystallography. Compared to the pyrrolidinedithiocarbamate ligand itself, this gold(III) complex displays an up to 33-fold higher anti-cancer potency towards a panel of cancer cell lines including the cisplatin-resistant ovarian carcinoma cell line (A2780cis). As demonstrated by a set of Transwell® assay-based cytotoxicity experiments, incorporating this gold(III) complex in a zinc-based biodegradable metal-organic framework (MOF) displays a significant enhancement in anti-cancer activity towards A2780cis than the gold(III) complex alone. Copyright © 2016 Elsevier Inc. All rights reserved.
Kohonen, Pekka; Benfenati, Emilio; Bower, David; Ceder, Rebecca; Crump, Michael; Cross, Kevin; Grafström, Roland C; Healy, Lyn; Helma, Christoph; Jeliazkova, Nina; Jeliazkov, Vedrin; Maggioni, Silvia; Miller, Scott; Myatt, Glenn; Rautenberg, Michael; Stacey, Glyn; Willighagen, Egon; Wiseman, Jeff; Hardy, Barry
2013-01-01
The aim of the SEURAT-1 (Safety Evaluation Ultimately Replacing Animal Testing-1) research cluster, comprised of seven EU FP7 Health projects co-financed by Cosmetics Europe, is to generate a proof-of-concept to show how the latest technologies, systems toxicology and toxicogenomics can be combined to deliver a test replacement for repeated dose systemic toxicity testing on animals. The SEURAT-1 strategy is to adopt a mode-of-action framework to describe repeated dose toxicity, combining in vitro and in silico methods to derive predictions of in vivo toxicity responses. ToxBank is the cross-cluster infrastructure project whose activities include the development of a data warehouse to provide a web-accessible shared repository of research data and protocols, a physical compounds repository, reference or "gold compounds" for use across the cluster (available via wiki.toxbank.net), and a reference resource for biomaterials. Core technologies used in the data warehouse include the ISA-Tab universal data exchange format, REpresentational State Transfer (REST) web services, the W3C Resource Description Framework (RDF) and the OpenTox standards. We describe the design of the data warehouse based on cluster requirements, the implementation based on open standards, and finally the underlying concepts and initial results of a data analysis utilizing public data related to the gold compounds. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Compliance with the guide for commissioning oral surgery: an audit and discussion.
Modgill, O; Shah, A
2017-10-13
Introduction The Guide for commissioning oral surgery and oral medicine published by NHS England (2015) prescribes the level of complexity of oral surgery and oral medicine investigations and procedures to be carried out within NHS services. These are categorised as Level 1, Level 2, Level 3A and Level 3B. An audit was designed to ascertain the level of oral surgery procedures performed by clinicians of varying experience and qualification working in a large oral surgery department within a major teaching hospital.Materials and methods Two audit cycles were conducted on retrospective case notes and radiographic review of 100 patient records undergoing dental extractions within the Department of Oral Surgery at King's College Dental Hospital. The set gold standard was: '100% of Level 1 procedures should be performed by dental undergraduates or discharged back to the referring general dental practitioner'. Data were collected and analysed on a Microsoft Excel spreadsheet. The results of the first audit cycle were presented to all clinicians within the department in a formal meeting, recommendations were made and an action plan implemented prior to undertaking a second cycle.Results The first cycle revealed that 25% of Level 1 procedures met the set gold standard, with Level 2 practitioners performing the majority of Level 1 and Level 2 procedures. The second cycle showed a marked improvement, with 66% of Level 1 procedures meeting the set gold standard.Conclusion Our audit demonstrates that whilst we were able to achieve an improvement with the set gold standard, several barriers still remain to ensure that patients are treated by the appropriate level of clinician in a secondary care setting. We have used this audit as a foundation upon which to discuss the challenges faced in implementation of the commissioning framework within both primary and secondary dental care and strategies to overcome these challenges, which are likely to be encountered in any NHS care setting in which oral surgery procedures are performed.
Chen, Fu-Li; Lee, Albert
2016-03-01
The Taiwan Ministry of Health and Welfare and Ministry of Education launched the Health-Promoting School (HPS) program in 2002. One of the most significant barriers to evaluating HPS is the absence of adequate instruments. The main aim of this study is to develop the Taiwan Health-Promoting School Accreditation System (HPSAS) framework and then evaluate its accreditation effectiveness. The HPSAS accreditation standards were derived mainly from the World Health Organization (WHO) publication, WHO Health Promoting Schools: A Framework for Action in 2008 and the Taiwan School Health Act. Delphi technique and pilot test were used to confirm the availability and acceptability of the standards and procedures for HPSAS in 2011. After that, two rounds of school evaluations were completed in 2012 (214 participant schools) and 2014 (182 participant schools). The accreditation operation process included documentary reviews, national and international accredited commissioners conducted on-site visits. Descriptive analyses were used to indicate HPS award level distribution. The study established six key HPSAS standards. Each standard had at least two components; overall, there were 21 components and 47 scoring elements. Of the participating schools evaluated in 2012, four were at the gold, 14 silver, and 120 bronze levels, compared with five, 20, and 31, respectively, of schools evaluated in 2014. The study showed that schools at different award levels had different full-score rates in six standards. The schools at the gold level performed exceptionally well. The worst performance among the six standards at each award level was in the skill-based health curriculum. The HPSAS is an objective instrument used to evaluate the process and outcomes of the HPS program. In the future, combinations of different types of data (e.g. students' health behaviors, school climate, or teachers' health-teaching innovations) will enable further validation of the HPS effectiveness. © The Author(s) 2016.
Yoshinari, Masao; Uzawa, Shinobu; Komiyama, Yataro
2016-10-01
The aim of this in vitro study was to evaluate tensile bond strengths and corrosion resistance of CoCr alloys joined with gold cylinder by a soldering system in comparison with the conventional cast-joining system. CoCr alloys joined with gold cylinder by a soldering system using a high-fusing gold solder (CoCr/Solder/Gold cylinder), gold alloy joined with gold cylinder by a cast joining system (Gold alloy/Gold cylinder) and CoCr castings were fabricated. The tensile bond strength and corrosion resistance in 0.9% NaCl solution (pH 7.4 and pH 2.3) were evaluated. Scanning electron microscopy (SEM) of the fractured surface and electron probe microanalysis (EPMA) of the joined interfaces were also performed. The tensile bond strengths of the CoCr/Solder/Gold cylinder specimens showed similar values as the Gold alloy/Gold cylinder specimens. SEM observation and EPMA analyses suggested firm bonding between the CoCr alloy and gold cylinder. The released elements from the CoCr/Solder/Gold cylinder specimens were similar to ones from CoCr castings. Results showed that superstructures made of CoCr alloys joined with the gold cylinder using a high-fusing gold solder had sufficient bond strength and high corrosion resistance. These hybrid frameworks with cobalt-chromium alloy and gold cylinder are promising prosthesis for implant superstructures with the low cost and favorable mechanical properties instead of conventional high-gold alloys. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Framework Surgery for Treatment of Unilateral Vocal Fold Paralysis
Daniero, James J.; Garrett, C. Gaelyn; Francis, David O.
2014-01-01
Laryngeal framework surgery is the current gold standard treatment for unilateral vocal fold paralysis. It provides a permanent solution to glottic insufficiency caused by injury to the recurrent laryngeal nerve. Various modifications to the original Isshiki type I laryngoplasty procedure have been described to improve voice and swallowing outcomes. The success of this procedure is highly dependent on the experience of the surgeon as it epitomizes the intersection of art and science in the field. The following article reviews the evidence, controversies, and complications related to laryngoplasty for unilateral vocal fold paralysis. It also provides a detailed analysis of how and when arytenoid-positioning procedures should be considered, and summarizes the literature on postoperative outcomes. PMID:24883239
Basic research in evolution and ecology enhances forensics.
Tomberlin, Jeffery K; Benbow, M Eric; Tarone, Aaron M; Mohr, Rachel M
2011-02-01
In 2009, the National Research Council recommended that the forensic sciences strengthen their grounding in basic empirical research to mitigate against criticism and improve accuracy and reliability. For DNA-based identification, this goal was achieved under the guidance of the population genetics community. This effort resulted in DNA analysis becoming the 'gold standard' of the forensic sciences. Elsewhere, we proposed a framework for streamlining research in decomposition ecology, which promotes quantitative approaches to collecting and applying data to forensic investigations involving decomposing human remains. To extend the ecological aspects of this approach, this review focuses on forensic entomology, although the framework can be extended to other areas of decomposition. Published by Elsevier Ltd.
Javaid, M K; Kyer, C; Mitchell, P J; Chana, J; Moss, C; Edwards, M H; McLellan, A R; Stenmark, J; Pierroz, D D; Schneider, M C; Kanis, J A; Akesson, K; Cooper, C
2015-11-01
Fracture Liaison Services are the best model to prevent secondary fractures. The International Osteoporosis Foundation developed a Best Practice Framework to provide a quality benchmark. After a year of implementation, we confirmed that a single framework with set criteria is able to benchmark services across healthcare systems worldwide. Despite evidence for the clinical effectiveness of secondary fracture prevention, translation in the real-world setting remains disappointing. Where implemented, a wide variety of service models are used to deliver effective secondary fracture prevention. To support use of effective models of care across the globe, the International Osteoporosis Foundation's Capture the Fracture® programme developed a Best Practice Framework (BPF) tool of criteria and standards to provide a quality benchmark. We now report findings after the first 12 months of implementation. A questionnaire for the BPF was created and made available to institutions on the Capture the Fracture website. Responses from institutions were used to assign gold, silver, bronze or black (insufficient) level of achievements mapped across five domains. Through an interactive process with the institution, a final score was determined and published on the Capture the Fracture website Fracture Liaison Service (FLS) map. Sixty hospitals across six continents submitted their questionnaires. The hospitals served populations from 20,000 to 15 million and were a mix of private and publicly funded. Each FLS managed 146 to 6200 fragility fracture patients per year with a total of 55,160 patients across all sites. Overall, 27 hospitals scored gold, 23 silver and 10 bronze. The pathway for the hip fracture patients had the highest proportion of gold grading while vertebral fracture the lowest. In the first 12 months, we have successfully tested the BPF tool in a range of health settings across the globe. Initial findings confirm a significant heterogeneity in service provision and highlight the importance of a global approach to ensure high quality secondary fracture prevention services.
Electrochemical properties of nanostructured porous gold electrodes in biofouling solutions.
Patel, Jay; Radhakrishnan, Logudurai; Zhao, Bo; Uppalapati, Badharinadh; Daniels, Rodney C; Ward, Kevin R; Collinson, Maryanne M
2013-12-03
The effect of electrode porosity on the electrochemical response of redox active molecules (potassium ferricyanide, ruthenium(III) hexammine, and ferrocene methanol) in the presence of bovine serum albumin or fibrinogen was studied at macroporous (pore diameter: 1200 nm), hierarchical (1200/60 nm), and nanoporous (<50 nm) gold. These electrodes were prepared using standard templating or dealloying techniques, and cyclic voltammetry (CV) was utilized to evaluate the effect of protein adsorption on the electron transfer of the diffusing redox probes. Following exposure to albumin (or fibrinogen) under near neutral pH conditions, planar gold electrodes showed an immediate reduction in Faradaic peak current and increase in peak splitting for potassium ferricyanide. The rate at which the CV curves changed was highly dependent on the morphology of the electrode. For example, the time required for the Faradaic current to drop to one-half of its original value was 3, 12, and 38 min for planar gold, macroporous gold, and hierarchical gold, respectively. Remarkably, for nanoporous gold, only a few percent drop in the peak Faradaic current was observed after an hour in solution. A similar suppression in the voltammetry at planar gold was also noted for ruthenium hexammine at pH 3 after exposure to albumin for several hours. At nanoporous gold, no significant loss in response was observed. The order of performance of the electrodes as judged by their ability to efficiently transfer electrons in the presence of biofouling agents tracked porosity with the electrode having the smallest pore size and largest surface area, providing near ideal results. Nanoporous gold electrodes when immersed in serum or heparinized blood containing potassium ferricyanide showed ideal voltammetry while significant fouling was evident in the electrochemical response at planar gold. The small nanopores in this 3D open framework are believed to restrict the transport of large biomolecules, thus minimizing passivation of the inner surfaces while permitting access to small redox probes to efficiently exchange electrons.
SCIFIO: an extensible framework to support scientific image formats.
Hiner, Mark C; Rueden, Curtis T; Eliceiri, Kevin W
2016-12-07
No gold standard exists in the world of scientific image acquisition; a proliferation of instruments each with its own proprietary data format has made out-of-the-box sharing of that data nearly impossible. In the field of light microscopy, the Bio-Formats library was designed to translate such proprietary data formats to a common, open-source schema, enabling sharing and reproduction of scientific results. While Bio-Formats has proved successful for microscopy images, the greater scientific community was lacking a domain-independent framework for format translation. SCIFIO (SCientific Image Format Input and Output) is presented as a freely available, open-source library unifying the mechanisms of reading and writing image data. The core of SCIFIO is its modular definition of formats, the design of which clearly outlines the components of image I/O to encourage extensibility, facilitated by the dynamic discovery of the SciJava plugin framework. SCIFIO is structured to support coexistence of multiple domain-specific open exchange formats, such as Bio-Formats' OME-TIFF, within a unified environment. SCIFIO is a freely available software library developed to standardize the process of reading and writing scientific image formats.
Strategic Framing Study Circles: toward a gold standard of framing pedagogy.
Feinberg, Jane
2009-01-01
This article explains how communities of practice have been developed as part of FrameWorks' field-building efforts. Strategic Framing Study Circles, as they are known, have been conducted with four statewide coalitions, one group of national organizations, and an emerging regional coalition. The goal of each community of practice is to build among participants a solid base of framing skills and competencies and to help them understand that despite varied organizational agendas, they can share a frame to tremendous collective advantage.
Schimpl, Michaela; Lederer, Christian; Daumer, Martin
2011-01-01
Walking speed is a fundamental indicator for human well-being. In a clinical setting, walking speed is typically measured by means of walking tests using different protocols. However, walking speed obtained in this way is unlikely to be representative of the conditions in a free-living environment. Recently, mobile accelerometry has opened up the possibility to extract walking speed from long-time observations in free-living individuals, but the validity of these measurements needs to be determined. In this investigation, we have developed algorithms for walking speed prediction based on 3D accelerometry data (actibelt®) and created a framework using a standardized data set with gold standard annotations to facilitate the validation and comparison of these algorithms. For this purpose 17 healthy subjects operated a newly developed mobile gold standard while walking/running on an indoor track. Subsequently, the validity of 12 candidate algorithms for walking speed prediction ranging from well-known simple approaches like combining step length with frequency to more sophisticated algorithms such as linear and non-linear models was assessed using statistical measures. As a result, a novel algorithm employing support vector regression was found to perform best with a concordance correlation coefficient of 0.93 (95%CI 0.92–0.94) and a coverage probability CP1 of 0.46 (95%CI 0.12–0.70) for a deviation of 0.1 m/s (CP2 0.78, CP3 0.94) when compared to the mobile gold standard while walking indoors. A smaller outdoor experiment confirmed those results with even better coverage probability. We conclude that walking speed thus obtained has the potential to help establish walking speed in free-living environments as a patient-oriented outcome measure. PMID:21850254
Wang, Yanzhao; Wang, Zhixun; Li, Yuxue; Wu, Gongde; Cao, Zheng; Zhang, Liming
2014-04-07
Most homogenous gold catalyses demand ≥ 0.5 mol% catalyst loading. Owing to the high cost of gold, these reactions are unlikely to be applicable in medium- or large-scale applications. Here we disclose a novel ligand design based on the privileged (1,1'-biphenyl)-2-ylphosphine framework that offers a potentially general approach to dramatically lowering catalyst loading. In this design, an amide group at the 3'-position of the ligand framework directs and promotes nucleophilic attack at the ligand gold complex-activated alkyne, which is unprecedented in homogenous gold catalysis considering the spatial challenge of using ligand to reach anti-approaching nucleophile in a linear P-Au-alkyne centroid structure. With such a ligand, the gold(I) complex becomes highly efficient in catalysing acid addition to alkynes, with a turnover number up to 99,000. Density functional theory calculations support the role of the amide moiety in directing the attack of carboxylic acid via hydrogen bonding.
Wang, Yanzhao; Wang, Zhixun; Li, Yuxue; Wu, Gongde; Cao, Zheng; Zhang, Liming
2014-01-01
Most homogenous gold catalyses demand ≥0.5 mol % catalyst loading. Due to the high cost of gold, these reactions are unlikely to be applicable in medium or large scale applications. Here we disclose a novel ligand design based on the privileged biphenyl-2-phosphine framework that offers a potentially general approach to dramatically lowering catalyst loading. In this design, an amide group at the 3’ position of the ligand framework directs and promotes nucleophilic attack at the ligand gold complex-activated alkyne, which is unprecedented in homogeneous gold catalysis considering the spatial challenge of using ligand to reach antiapproaching nucleophile in a linear P-Au-alkyne centroid structure. With such a ligand, the gold(I) complex becomes highly efficient in catalyzing acid addition to alkynes, with a turnover number up to 99,000. Density functional theory calculations support the role of the amide moiety in directing the attack of carboxylic acid via hydrogen bonding. PMID:24704803
Burns, Lucinda; Coleman-Cowger, Victoria H.; Breen, Courtney
2016-01-01
Substance use in pregnancy can have adverse effects on mother and fetus alike. Australia and the US are countries with high levels of substance use and policies advising abstinence, although the Australian approach occurs within a broader framework of harm minimization. Less attention has been paid to treatment of the mothers’ substance use and what is considered gold standard. This is despite evidence that prior substance use in pregnancy is the most important factor in predicting future substance use in pregnancy. This paper draws together information from both the peer-reviewed and gray literature to provide a contemporary overview of patterns and outcomes of the three main drugs, alcohol, tobacco, and cannabis, used in Australia and the US during pregnancy and discusses what are considered gold standard screening and treatment approaches for these substances. This paper does not set out to be a comprehensive review of the area but rather aims to provide a concise summary of current guidelines for policy makers and practitioners who provide treatment for women who use substances in pregnancy. PMID:27980414
Automating Assessment of Lifestyle Counseling in Electronic Health Records
Hazlehurst, Brian L.; Lawrence, Jean M.; Donahoo, William T.; Sherwood, Nancy E; Kurtz, Stephen E; Xu, Stan; Steiner, John F
2015-01-01
Background Numerous population-based surveys indicate that overweight and obese patients can benefit from lifestyle counseling during routine clinical care. Purpose To determine if natural language processing (NLP) could be applied to information in the electronic health record (EHR) to automatically assess delivery of counseling related to weight management in clinical health care encounters. Methods The MediClass system with NLP capabilities was used to identify weight management counseling in EHR encounter records. Knowledge for the NLP application was derived from the 5As framework for behavior counseling: Ask (evaluate weight and related disease), Advise at-risk patients to lose weight, Assess patients’ readiness to change behavior, Assist through discussion of weight loss methods and programs and Arrange follow-up efforts including referral. Using samples of EHR data in 1/1/2007-3/31/2011 period from two health systems, the accuracy of the MediClass processor for identifying these counseling elements was evaluated in post-partum visits of 600 women with gestational diabetes mellitus (GDM) compared to manual chart review as gold standard. Data were analyzed in 2013. Results Mean sensitivity and specificity for each of the 5As compared to the gold standard was at or above 85%, with the exception of sensitivity for Assist which was measured at 40% and 60% respectively for each of the two health systems. The automated method identified many valid cases of Assist not identified in the gold standard. Conclusions The MediClass processor has performance capability sufficiently similar to human abstractors to permit automated assessment of counseling for weight loss in post-partum encounter records. PMID:24745635
Automating assessment of lifestyle counseling in electronic health records.
Hazlehurst, Brian L; Lawrence, Jean M; Donahoo, William T; Sherwood, Nancy E; Kurtz, Stephen E; Xu, Stan; Steiner, John F
2014-05-01
Numerous population-based surveys indicate that overweight and obese patients can benefit from lifestyle counseling during routine clinical care. To determine if natural language processing (NLP) could be applied to information in the electronic health record (EHR) to automatically assess delivery of weight management-related counseling in clinical healthcare encounters. The MediClass system with NLP capabilities was used to identify weight-management counseling in EHRs. Knowledge for the NLP application was derived from the 5As framework for behavior counseling: Ask (evaluate weight and related disease), Advise at-risk patients to lose weight, Assess patients' readiness to change behavior, Assist through discussion of weight-loss methods and programs, and Arrange follow-up efforts including referral. Using samples of EHR data between January 1, 2007, and March 31, 2011, from two health systems, the accuracy of the MediClass processor for identifying these counseling elements was evaluated in postpartum visits of 600 women with gestational diabetes mellitus (GDM) compared to manual chart review as the gold standard. Data were analyzed in 2013. Mean sensitivity and specificity for each of the 5As compared to the gold standard was at or above 85%, with the exception of sensitivity for Assist, which was 40% and 60% for each of the two health systems. The automated method identified many valid Assist cases not identified in the gold standard. The MediClass processor has performance capability sufficiently similar to human abstractors to permit automated assessment of counseling for weight loss in postpartum encounter records. Copyright © 2014 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Left Ventricular Endocardium Tracking by Fusion of Biomechanical and Deformable Models
Gu, Jason
2014-01-01
This paper presents a framework for tracking left ventricular (LV) endocardium through 2D echocardiography image sequence. The framework is based on fusion of biomechanical (BM) model of the heart with the parametric deformable model. The BM model constitutive equation consists of passive and active strain energy functions. The deformations of the LV are obtained by solving the constitutive equations using ABAQUS FEM in each frame in the cardiac cycle. The strain energy functions are defined in two user subroutines for active and passive phases. Average fusion technique is used to fuse the BM and deformable model contours. Experimental results are conducted to verify the detected contours and the results are evaluated by comparing themto a created gold standard. The results and the evaluation proved that the framework has the tremendous potential to track and segment the LV through the whole cardiac cycle. PMID:24587814
Advocacy: Making the Gold Standard School a Reality
ERIC Educational Resources Information Center
Roberts, Julia Link; Inman, Tracy Ford
2011-01-01
In their last column, the authors described a Gold Standard School--a place in which all children thrive including the gifted and talented. The Checklist for a Gold Standard School, which is included in this article, highlights the main characteristics of such a school including a focus on continuous progress, talent development, policies that…
When the value of gold is zero.
Chase, J Geoffrey; Moeller, Knut; Shaw, Geoffrey M; Schranz, Christoph; Chiew, Yeong Shiong; Desaive, Thomas
2014-06-27
This manuscript presents the concerns around the increasingly common problem of not having readily available or useful "gold standard" measurements. This issue is particularly important in critical care where many measurements used in decision making are surrogates of what we would truly wish to use. However, the question is broad, important and applicable in many other areas.In particular, a gold standard measurement often exists, but is not clinically (or ethically in some cases) feasible. The question is how does one even begin to develop new measurements or surrogates if one has no gold standard to compare with?We raise this issue concisely with a specific example from mechanical ventilation, a core bread and butter therapy in critical care that is also a leading cause of length of stay and cost of care. Our proposed solution centers around a hierarchical validation approach that we believe would ameliorate ethics issues around radiation exposure that make current gold standard measures clinically infeasible, and thus provide a pathway to create a (new) gold standard.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., silver, gold, or platinum level of coverage is referred to as a standard bronze plan, a standard silver plan, a standard gold plan, and a standard platinum plan, respectively. Zero cost sharing plan...
Teigen, Kyrre; Jokstad, Asbjørn
2012-07-01
An association between the long-term success and survival of implant-supported prostheses as a function of biomaterial combinations has not been established. The use of cast cobalt-chromium for the suprastructure framework may be an alternative to the conventional approach of using type 3 gold alloys. A retrospective chart audit of all patients who had received implant-supported fixed dental prostheses (FDP) before 1996 was identified in a private practice clinic. Data were recorded for FDPs made from four combinations of alloy frameworks and veneering material, i.e. type 3 gold and cobalt-chromium with ceramic or prefabricated acrylic teeth. The extracted data from the charts were subjected to explorative statistical tests including Kaplan-Meier survival analyses. Patients (n=198) with 270 short and extensive FDPs supported entirely by 1117 implants were identified. The average follow-up observation periods varied between 4 and 220 months, with an average of 120 months. The success and survival, as well as event rates and types of biological and technical complications, were similar for implant-supported FDPs using cobalt-chromium and type 3 gold alloy frameworks veneered with ceramics or prefabricated acrylic teeth. An influence of the suprastructure biomaterial combination on the clinical performance of the individual supporting implants could not be established. Implant-supported FDPs made from type 3 gold or cobalt-chromium frameworks and veneered with ceramic or prefabricated acrylic teeth demonstrate comparable clinical performance. The biomaterial combinations do not appear to influence the success or survival of the individual implants. © 2011 John Wiley & Sons A/S.
Petrović, Ivana B.; Vukelić, Milica; Čizmić, Svetlana
2017-01-01
Researchers are still searching for the ways to identify different categories of employees according to their exposure to negative acts and psychological experience of workplace bullying. We followed Notelaers and Einarsen’s application of the ROC analysis to determine the NAQ-R cut-off scores applying a “lower” and “higher” threshold. The main goal of this research was to develop and test different gold standards of personal and organizational relevance in determining the NAQ-R cut-off scores in a specific cultural and economic context of Serbia. Apart from combining self-labeling as a victim with self-perceived health, the objectives were to test the gold standards developed as a combination of self-labeling with life satisfaction, self-labeling with intention to leave and a complex gold standard based on self-labeling, self-perceived health, life satisfaction and intention to leave taken together. The ROC analysis on Serbian workforce data supports applying of different gold standards. For identifying employees in a preliminary stage of bullying, the most applicable was the gold standard based on self-labeling and intention to leave (score 34 and higher). The most accurate identification of victims could be based on the most complex gold standard (score 81 and higher). This research encourages further investigation of gold standards in different cultures. PMID:28119652
Duque-Ramos, Astrid; Boeker, Martin; Jansen, Ludger; Schulz, Stefan; Iniesta, Miguela; Fernández-Breis, Jesualdo Tomás
2014-01-01
Objective To (1) evaluate the GoodOD guideline for ontology development by applying the OQuaRE evaluation method and metrics to the ontology artefacts that were produced by students in a randomized controlled trial, and (2) informally compare the OQuaRE evaluation method with gold standard and competency questions based evaluation methods, respectively. Background In the last decades many methods for ontology construction and ontology evaluation have been proposed. However, none of them has become a standard and there is no empirical evidence of comparative evaluation of such methods. This paper brings together GoodOD and OQuaRE. GoodOD is a guideline for developing robust ontologies. It was previously evaluated in a randomized controlled trial employing metrics based on gold standard ontologies and competency questions as outcome parameters. OQuaRE is a method for ontology quality evaluation which adapts the SQuaRE standard for software product quality to ontologies and has been successfully used for evaluating the quality of ontologies. Methods In this paper, we evaluate the effect of training in ontology construction based on the GoodOD guideline within the OQuaRE quality evaluation framework and compare the results with those obtained for the previous studies based on the same data. Results Our results show a significant effect of the GoodOD training over developed ontologies by topics: (a) a highly significant effect was detected in three topics from the analysis of the ontologies of untrained and trained students; (b) both positive and negative training effects with respect to the gold standard were found for five topics. Conclusion The GoodOD guideline had a significant effect over the quality of the ontologies developed. Our results show that GoodOD ontologies can be effectively evaluated using OQuaRE and that OQuaRE is able to provide additional useful information about the quality of the GoodOD ontologies. PMID:25148262
Duque-Ramos, Astrid; Boeker, Martin; Jansen, Ludger; Schulz, Stefan; Iniesta, Miguela; Fernández-Breis, Jesualdo Tomás
2014-01-01
To (1) evaluate the GoodOD guideline for ontology development by applying the OQuaRE evaluation method and metrics to the ontology artefacts that were produced by students in a randomized controlled trial, and (2) informally compare the OQuaRE evaluation method with gold standard and competency questions based evaluation methods, respectively. In the last decades many methods for ontology construction and ontology evaluation have been proposed. However, none of them has become a standard and there is no empirical evidence of comparative evaluation of such methods. This paper brings together GoodOD and OQuaRE. GoodOD is a guideline for developing robust ontologies. It was previously evaluated in a randomized controlled trial employing metrics based on gold standard ontologies and competency questions as outcome parameters. OQuaRE is a method for ontology quality evaluation which adapts the SQuaRE standard for software product quality to ontologies and has been successfully used for evaluating the quality of ontologies. In this paper, we evaluate the effect of training in ontology construction based on the GoodOD guideline within the OQuaRE quality evaluation framework and compare the results with those obtained for the previous studies based on the same data. Our results show a significant effect of the GoodOD training over developed ontologies by topics: (a) a highly significant effect was detected in three topics from the analysis of the ontologies of untrained and trained students; (b) both positive and negative training effects with respect to the gold standard were found for five topics. The GoodOD guideline had a significant effect over the quality of the ontologies developed. Our results show that GoodOD ontologies can be effectively evaluated using OQuaRE and that OQuaRE is able to provide additional useful information about the quality of the GoodOD ontologies.
Hansmann, Max M; Rudolph, Matthias; Rominger, Frank; Hashmi, A Stephen K
2013-02-25
The other side of the mountain: Changing the framework of diyne systems opens up new cyclization modes for dual gold catalysis. Instead of a 5-endo cyclization and gold vinylidenes a 6-endo cyclization gives rise to gold-stabilized carbenes as key intermediates for selective C-H insertions. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Martin, Shelby; Wagner, Jesse; Lupulescu-Mann, Nicoleta; Ramsey, Katrina; Cohen, Aaron; Graven, Peter; Weiskopf, Nicole G; Dorr, David A
2017-08-02
To measure variation among four different Electronic Health Record (EHR) system documentation locations versus 'gold standard' manual chart review for risk stratification in patients with multiple chronic illnesses. Adults seen in primary care with EHR evidence of at least one of 13 conditions were included. EHRs were manually reviewed to determine presence of active diagnoses, and risk scores were calculated using three different methodologies and five EHR documentation locations. Claims data were used to assess cost and utilization for the following year. Descriptive and diagnostic statistics were calculated for each EHR location. Criterion validity testing compared the gold standard verified diagnoses versus other EHR locations and risk scores in predicting future cost and utilization. Nine hundred patients had 2,179 probable diagnoses. About 70% of the diagnoses from the EHR were verified by gold standard. For a subset of patients having baseline and prediction year data (n=750), modeling showed that the gold standard was the best predictor of outcomes on average for a subset of patients that had these data. However, combining all data sources together had nearly equivalent performance for prediction as the gold standard. EHR data locations were inaccurate 30% of the time, leading to improvement in overall modeling from a gold standard from chart review for individual diagnoses. However, the impact on identification of the highest risk patients was minor, and combining data from different EHR locations was equivalent to gold standard performance. The reviewer's ability to identify a diagnosis as correct was influenced by a variety of factors, including completeness, temporality, and perceived accuracy of chart data.
Aguiar, Lorena Andrade de; Melo, Lauro; de Lacerda de Oliveira, Lívia
2018-04-03
A major drawback of conventional descriptive profile (CDP) in sensory evaluation is the long time spent in panel training. Rapid descriptive methods (RDM) have increased significantly. Some of them have been compared with CDP for validation. In Health Sciences, systematic reviews (SR) are performed to evaluate validation of diagnostic tests in relation to a gold standard method. SR present a well-defined protocol to summarize research evidence and to evaluate the quality of the studies with determined criteria. We adapted SR protocol to evaluate the validation of RDM against CDP as satisfactory procedures to obtain food characterization. We used "Population Intervention Comparison Outcome Study - PICOS" framework to design the research in which "Population" was food/ beverages; "intervention" were RDM, "Comparison" was CDP as gold standard, "Outcome" was the ability of RDM to generate similar descriptive profiles in comparison with CDP and "Studies" was sensory descriptive analyses. The proportion of studies concluding for similarity of the RDM with CDP ranged from 0% to 100%. Low and moderate risk of bias were reached by 87% and 13% of the studies, respectively, supporting the conclusions of SR. RDM with semi-trained assessors and evaluation of individual attributes presented higher percentages of concordance with CDP.
NASA Astrophysics Data System (ADS)
Roslindar Yaziz, Siti; Zakaria, Roslinazairimah; Hura Ahmad, Maizah
2017-09-01
The model of Box-Jenkins - GARCH has been shown to be a promising tool for forecasting higher volatile time series. In this study, the framework of determining the optimal sample size using Box-Jenkins model with GARCH is proposed for practical application in analysing and forecasting higher volatile data. The proposed framework is employed to daily world gold price series from year 1971 to 2013. The data is divided into 12 different sample sizes (from 30 to 10200). Each sample is tested using different combination of the hybrid Box-Jenkins - GARCH model. Our study shows that the optimal sample size to forecast gold price using the framework of the hybrid model is 1250 data of 5-year sample. Hence, the empirical results of model selection criteria and 1-step-ahead forecasting evaluations suggest that the latest 12.25% (5-year data) of 10200 data is sufficient enough to be employed in the model of Box-Jenkins - GARCH with similar forecasting performance as by using 41-year data.
An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.
Obuchowski, Nancy A
2006-02-15
ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.
Jha, Abhinav K.; Kupinski, Matthew A.; Rodríguez, Jeffrey J.; Stephen, Renu M.; Stopeck, Alison T.
2012-01-01
In many studies, the estimation of the apparent diffusion coefficient (ADC) of lesions in visceral organs in diffusion-weighted (DW) magnetic resonance images requires an accurate lesion-segmentation algorithm. To evaluate these lesion-segmentation algorithms, region-overlap measures are used currently. However, the end task from the DW images is accurate ADC estimation, and the region-overlap measures do not evaluate the segmentation algorithms on this task. Moreover, these measures rely on the existence of gold-standard segmentation of the lesion, which is typically unavailable. In this paper, we study the problem of task-based evaluation of segmentation algorithms in DW imaging in the absence of a gold standard. We first show that using manual segmentations instead of gold-standard segmentations for this task-based evaluation is unreliable. We then propose a method to compare the segmentation algorithms that does not require gold-standard or manual segmentation results. The no-gold-standard method estimates the bias and the variance of the error between the true ADC values and the ADC values estimated using the automated segmentation algorithm. The method can be used to rank the segmentation algorithms on the basis of both accuracy and precision. We also propose consistency checks for this evaluation technique. PMID:22713231
Boosting drug named entity recognition using an aggregate classifier.
Korkontzelos, Ioannis; Piliouras, Dimitrios; Dowsey, Andrew W; Ananiadou, Sophia
2015-10-01
Drug named entity recognition (NER) is a critical step for complex biomedical NLP tasks such as the extraction of pharmacogenomic, pharmacodynamic and pharmacokinetic parameters. Large quantities of high quality training data are almost always a prerequisite for employing supervised machine-learning techniques to achieve high classification performance. However, the human labour needed to produce and maintain such resources is a significant limitation. In this study, we improve the performance of drug NER without relying exclusively on manual annotations. We perform drug NER using either a small gold-standard corpus (120 abstracts) or no corpus at all. In our approach, we develop a voting system to combine a number of heterogeneous models, based on dictionary knowledge, gold-standard corpora and silver annotations, to enhance performance. To improve recall, we employed genetic programming to evolve 11 regular-expression patterns that capture common drug suffixes and used them as an extra means for recognition. Our approach uses a dictionary of drug names, i.e. DrugBank, a small manually annotated corpus, i.e. the pharmacokinetic corpus, and a part of the UKPMC database, as raw biomedical text. Gold-standard and silver annotated data are used to train maximum entropy and multinomial logistic regression classifiers. Aggregating drug NER methods, based on gold-standard annotations, dictionary knowledge and patterns, improved the performance on models trained on gold-standard annotations, only, achieving a maximum F-score of 95%. In addition, combining models trained on silver annotations, dictionary knowledge and patterns are shown to achieve comparable performance to models trained exclusively on gold-standard data. The main reason appears to be the morphological similarities shared among drug names. We conclude that gold-standard data are not a hard requirement for drug NER. Combining heterogeneous models build on dictionary knowledge can achieve similar or comparable classification performance with that of the best performing model trained on gold-standard annotations. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
A two-step framework for the registration of HE stained and FTIR images
NASA Astrophysics Data System (ADS)
Peñaranda, Francisco; Naranjo, Valery; Verdú, Rafaél.; Lloyd, Gavin R.; Nallala, Jayakrupakar; Stone, Nick
2016-03-01
FTIR spectroscopy is an emerging technology with high potential for cancer diagnosis but with particular physical phenomena that require special processing. Little work has been done in the field with the aim of registering hyperspectral Fourier-Transform Infrared (FTIR) spectroscopic images and Hematoxilin and Eosin (HE) stained histological images of contiguous slices of tissue. This registration is necessary to transfer the location of relevant structures that the pathologist may identify in the gold standard HE images. A two-step registration framework is presented where a representative gray image extracted from the FTIR hypercube is used as an input. This representative image, which must have a spatial contrast as similar as possible to a gray image obtained from the HE image, is calculated through the spectrum variation in the fingerprint region. In the first step of the registration algorithm a similarity transformation is estimated from interest points, which are automatically detected by the popular SURF algorithm. In the second stage, a variational registration framework defined in the frequency domain compensates for local anatomical variations between both images. After a proper tuning of some parameters the proposed registration framework works in an automated way. The method was tested on 7 samples of colon tissue in different stages of cancer. Very promising qualitative and quantitative results were obtained (a mean correlation ratio of 92.16% with a standard deviation of 3.10%).
Electrocardiographic interpretation skills of cardiology residents: are they competent?
Sibbald, Matthew; Davies, Edward G; Dorian, Paul; Yu, Eric H C
2014-12-01
Achieving competency at electrocardiogram (ECG) interpretation among cardiology subspecialty residents has traditionally focused on interpreting a target number of ECGs during training. However, there is little evidence to support this approach. Further, there are no data documenting the competency of ECG interpretation skills among cardiology residents, who become de facto the gold standard in their practice communities. We tested 29 Cardiology residents from all 3 years in a large training program using a set of 20 ECGs collected from a community cardiology practice over a 1-month period. Residents interpreted half of the ECGs using a standard analytic framework, and half using their own approach. Residents were scored on the number of correct and incorrect diagnoses listed. Overall diagnostic accuracy was 58%. Of 6 potentially life-threatening diagnoses, residents missed 36% (123 of 348) including hyperkalemia (81%), long QT (52%), complete heart block (35%), and ventricular tachycardia (19%). Residents provided additional inappropriate diagnoses on 238 ECGs (41%). Diagnostic accuracy was similar between ECGs interpreted using an analytic framework vs ECGs interpreted without an analytic framework (59% vs 58%; F(1,1333) = 0.26; P = 0.61). Cardiology resident proficiency at ECG interpretation is suboptimal. Despite the use of an analytic framework, there remain significant deficiencies in ECG interpretation among Cardiology residents. A more systematic method of addressing these important learning gaps is urgently needed. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
The shape of Au8: gold leaf or gold nugget?
NASA Astrophysics Data System (ADS)
Serapian, Stefano A.; Bearpark, Michael J.; Bresme, Fernando
2013-06-01
The size at which nonplanar isomers of neutral, pristine gold nanoclusters become energetically favored over planar ones is still debated amongst theoreticians and experimentalists. Spectroscopy confirms planarity is preferred at sizes up to Au7, however, starting with Au8, the uncertainty remains for larger nanoclusters. Au8 computational studies have had different outcomes: the planar D4h ``cloverleaf'' isomer competes with the nonplanar Td, C2v and D2d ``nugget'' isomers for greatest energetic stability. We here examine the 2D vs. 3D preference in Au8 by presenting our own B2PLYP, MP2 and CCSD(T) calculations on these isomers: these methods afford a better treatment of long-range correlation, which is at the root of gold's characteristic aurophilicity. We then use findings from these high-accuracy computations to evaluate two less expensive DFT approaches, applicable to much larger nanoclusters: alongside the standard functional PBE, we consider M06-L (highly parametrized to incorporate long-range dispersive interactions). We find that increasing basis set size within the B2PLYP framework has a greater destabilizing effect on the nuggets than it has on the Au8 cloverleaf. Our CCSD(T) and B2PLYP predictions, replicated by DFT-PBE, all identify the cloverleaf as the most stable isomer; MP2 and DFT-M06-L show overestimation of aurophilicity, and favor, respectively, the nonplanar D2d and Td nuggets in its stead. We conclude that PBE, which more closely reproduces CCSD(T) findings, may be a better candidate density functional for the simulation of gold nanoclusters in this context.The size at which nonplanar isomers of neutral, pristine gold nanoclusters become energetically favored over planar ones is still debated amongst theoreticians and experimentalists. Spectroscopy confirms planarity is preferred at sizes up to Au7, however, starting with Au8, the uncertainty remains for larger nanoclusters. Au8 computational studies have had different outcomes: the planar D4h ``cloverleaf'' isomer competes with the nonplanar Td, C2v and D2d ``nugget'' isomers for greatest energetic stability. We here examine the 2D vs. 3D preference in Au8 by presenting our own B2PLYP, MP2 and CCSD(T) calculations on these isomers: these methods afford a better treatment of long-range correlation, which is at the root of gold's characteristic aurophilicity. We then use findings from these high-accuracy computations to evaluate two less expensive DFT approaches, applicable to much larger nanoclusters: alongside the standard functional PBE, we consider M06-L (highly parametrized to incorporate long-range dispersive interactions). We find that increasing basis set size within the B2PLYP framework has a greater destabilizing effect on the nuggets than it has on the Au8 cloverleaf. Our CCSD(T) and B2PLYP predictions, replicated by DFT-PBE, all identify the cloverleaf as the most stable isomer; MP2 and DFT-M06-L show overestimation of aurophilicity, and favor, respectively, the nonplanar D2d and Td nuggets in its stead. We conclude that PBE, which more closely reproduces CCSD(T) findings, may be a better candidate density functional for the simulation of gold nanoclusters in this context. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr01500a
Fully automated motion correction in first-pass myocardial perfusion MR image sequences.
Milles, Julien; van der Geest, Rob J; Jerosch-Herold, Michael; Reiber, Johan H C; Lelieveldt, Boudewijn P F
2008-11-01
This paper presents a novel method for registration of cardiac perfusion magnetic resonance imaging (MRI). The presented method is capable of automatically registering perfusion data, using independent component analysis (ICA) to extract physiologically relevant features together with their time-intensity behavior. A time-varying reference image mimicking intensity changes in the data of interest is computed based on the results of that ICA. This reference image is used in a two-pass registration framework. Qualitative and quantitative validation of the method is carried out using 46 clinical quality, short-axis, perfusion MR datasets comprising 100 images each. Despite varying image quality and motion patterns in the evaluation set, validation of the method showed a reduction of the average right ventricle (LV) motion from 1.26+/-0.87 to 0.64+/-0.46 pixels. Time-intensity curves are also improved after registration with an average error reduced from 2.65+/-7.89% to 0.87+/-3.88% between registered data and manual gold standard. Comparison of clinically relevant parameters computed using registered data and the manual gold standard show a good agreement. Additional tests with a simulated free-breathing protocol showed robustness against considerable deviations from a standard breathing protocol. We conclude that this fully automatic ICA-based method shows an accuracy, a robustness and a computation speed adequate for use in a clinical environment.
larvalign: Aligning Gene Expression Patterns from the Larval Brain of Drosophila melanogaster.
Muenzing, Sascha E A; Strauch, Martin; Truman, James W; Bühler, Katja; Thum, Andreas S; Merhof, Dorit
2018-01-01
The larval brain of the fruit fly Drosophila melanogaster is a small, tractable model system for neuroscience. Genes for fluorescent marker proteins can be expressed in defined, spatially restricted neuron populations. Here, we introduce the methods for 1) generating a standard template of the larval central nervous system (CNS), 2) spatial mapping of expression patterns from different larvae into a reference space defined by the standard template. We provide a manually annotated gold standard that serves for evaluation of the registration framework involved in template generation and mapping. A method for registration quality assessment enables the automatic detection of registration errors, and a semi-automatic registration method allows one to correct registrations, which is a prerequisite for a high-quality, curated database of expression patterns. All computational methods are available within the larvalign software package: https://github.com/larvalign/larvalign/releases/tag/v1.0.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-20
... published a proposed rule for mercury emissions from the gold mine ore processing and production area source... proposed rule (75 FR 22470). Several parties requested that EPA extend the comment period. EPA has granted...-AP48 National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production...
Park, Rebecca J.; Singh, Ilina; Pike, Alexandra C.; Tan, Jacinta O. A.
2017-01-01
Neurosurgical interventions for psychiatric disorders have a long and troubled history (1, 2) but have become much more refined in the last few decades due to the rapid development of neuroimaging and robotic technologies (2). These advances have enabled the design of less invasive techniques, which are more focused, such as deep brain stimulation (DBS) (3). DBS involves electrode insertion into specific neural targets implicated in pathological behavior, which are then repeatedly stimulated at adjustable frequencies. DBS has been used for Parkinson’s disease and movement disorders since the 1960s (4–6) and over the last decade has been applied to treatment-refractory psychiatric disorders, with some evidence of benefit in obsessive–compulsive disorder (OCD), major depressive disorder, and addictions (7). Recent consensus guidelines on best practice in psychiatric neurosurgery (8) stress, however, that DBS for psychiatric disorders remains at an experimental and exploratory stage. The ethics of DBS—in particular for psychiatric conditions—is debated (1, 8–10). Much of this discourse surrounds the philosophical implications of competence, authenticity, personality, or identity change following neurosurgical interventions, but there is a paucity of applied guidance on neuroethical best practice in psychiatric DBS, and health-care professionals have expressed that they require more (11). This paper aims to redress this balance by providing a practical, applied neuroethical gold standard framework to guide research ethics committees, researchers, and institutional sponsors. We will describe this as applied to our protocol for a particular research trial of DBS in severe and enduring anorexia nervosa (SE-AN) (https://clinicaltrials.gov/ct2/show/NCT01924598, unique identifier NCT01924598), but believe it may have wider application to DBS in other psychiatric disorders. PMID:28373849
ERIC Educational Resources Information Center
Thomas, Gary
2016-01-01
The past few years have seen a resurgence of faith in experimentation in education inquiry, and particularly in randomized controlled trials (RCTs). Proponents of such research have succeeded in bringing into common parlance the term "gold standard," which suggests that research emerging from any other design frame fails to achieve the…
Building a gold standard to construct search filters: a case study with biomarkers for oral cancer.
Frazier, John J; Stein, Corey D; Tseytlin, Eugene; Bekhuis, Tanja
2015-01-01
To support clinical researchers, librarians and informationists may need search filters for particular tasks. Development of filters typically depends on a "gold standard" dataset. This paper describes generalizable methods for creating a gold standard to support future filter development and evaluation using oral squamous cell carcinoma (OSCC) as a case study. OSCC is the most common malignancy affecting the oral cavity. Investigation of biomarkers with potential prognostic utility is an active area of research in OSCC. The methods discussed here should be useful for designing quality search filters in similar domains. The authors searched MEDLINE for prognostic studies of OSCC, developed annotation guidelines for screeners, ran three calibration trials before annotating the remaining body of citations, and measured inter-annotator agreement (IAA). We retrieved 1,818 citations. After calibration, we screened the remaining citations (n = 1,767; 97.2%); IAA was substantial (kappa = 0.76). The dataset has 497 (27.3%) citations representing OSCC studies of potential prognostic biomarkers. The gold standard dataset is likely to be high quality and useful for future development and evaluation of filters for OSCC studies of potential prognostic biomarkers. The methodology we used is generalizable to other domains requiring a reference standard to evaluate the performance of search filters. A gold standard is essential because the labels regarding relevance enable computation of diagnostic metrics, such as sensitivity and specificity. Librarians and informationists with data analysis skills could contribute to developing gold standard datasets and subsequent filters tuned for their patrons' domains of interest.
Device and methods for "gold standard" registration of clinical 3D and 2D cerebral angiograms
NASA Astrophysics Data System (ADS)
Madan, Hennadii; Likar, Boštjan; Pernuš, Franjo; Å piclin, Žiga
2015-03-01
Translation of any novel and existing 3D-2D image registration methods into clinical image-guidance systems is limited due to lack of their objective validation on clinical image datasets. The main reason is that, besides the calibration of the 2D imaging system, a reference or "gold standard" registration is very difficult to obtain on clinical image datasets. In the context of cerebral endovascular image-guided interventions (EIGIs), we present a calibration device in the form of a headband with integrated fiducial markers and, secondly, propose an automated pipeline comprising 3D and 2D image processing, analysis and annotation steps, the result of which is a retrospective calibration of the 2D imaging system and an optimal, i.e., "gold standard" registration of 3D and 2D images. The device and methods were used to create the "gold standard" on 15 datasets of 3D and 2D cerebral angiograms, whereas each dataset was acquired on a patient undergoing EIGI for either aneurysm coiling or embolization of arteriovenous malformation. The use of the device integrated seamlessly in the clinical workflow of EIGI. While the automated pipeline eliminated all manual input or interactive image processing, analysis or annotation. In this way, the time to obtain the "gold standard" was reduced from 30 to less than one minute and the "gold standard" of 3D-2D registration on all 15 datasets of cerebral angiograms was obtained with a sub-0.1 mm accuracy.
Jha, Abhinav K; Song, Na; Caffo, Brian; Frey, Eric C
2015-04-13
Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method provided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.
Santos, Eduardo Jose Melos Dos; McCabe, Antony; Gonzalez-Galarza, Faviel F; Jones, Andrew R; Middleton, Derek
2016-03-01
The Allele Frequencies Net Database (AFND) is a freely accessible database which stores population frequencies for alleles or genes of the immune system in worldwide populations. Herein we introduce two new tools. We have defined new classifications of data (gold, silver and bronze) to assist users in identifying the most suitable populations for their tasks. The gold standard datasets are defined by allele frequencies summing to 1, sample sizes >50 and high resolution genotyping, while silver standard datasets do not meet gold standard genotyping resolution and/or sample size criteria. The bronze standard datasets are those that could not be classified under the silver or gold standards. The gold standard includes >500 datasets covering over 3 million individuals from >100 countries at one or more of the following loci: HLA-A, -B, -C, -DPA1, -DPB1, -DQA1, -DQB1 and -DRB1 - with all loci except DPA1 present in more than 220 datasets. Three out of 12 geographic regions have low representation (the majority of their countries having less than five datasets) and the Central Asia region has no representation. There are 18 countries that are not represented by any gold standard datasets but are represented by at least one dataset that is either silver or bronze standard. We also briefly summarize the data held by AFND for KIR genes, alleles and their ligands. Our second new component is a data submission tool to assist users in the collection of the genotypes of the individuals (raw data), facilitating submission of short population reports to Human Immunology, as well as simplifying the submission of population demographics and frequency data. Copyright © 2015 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-11
... Programs Gold Standard Evaluation Follow-Up Surveys, Veterans Study, and Cost Data,'' to the Office of... Standard Evaluation Follow-Up Surveys, Veterans Study, and Cost Data ACTION: Notice. SUMMARY: The... Worker Programs Gold Standard Evaluation Follow-Up Surveys, Veterans Study, and Cost Data. OMB ICR...
NASA Astrophysics Data System (ADS)
Wei, Hua-Rong; Liu, Fu-Hu; Lacey, Roy A.
2016-12-01
In the framework of a multisource thermal model, we describe experimental results of the transverse momentum spectra of final-state light flavor particles produced in gold-gold (Au-Au), copper-copper (Cu-Cu), lead-lead (Pb-Pb), proton-lead (p-Pb), and proton-proton (p -p) collisions at various energies, measured by the PHENIX, STAR, ALICE, and CMS Collaborations, by using the Tsallis-standard (Tsallis form of Fermi-Dirac or Bose-Einstein), Tsallis, and two- or three-component standard distributions which can be in fact regarded as different types of ‘thermometers’ or ‘thermometric scales’ and ‘speedometers’. A central parameter in the three distributions is the effective temperature which contains information on the kinetic freeze-out temperature of the emitting source and reflects the effects of random thermal motion of particles as well as collective expansion of the source. To disentangle both effects, we extract the kinetic freeze-out temperature from the intercept of the effective temperature (T) curve as a function of particle’s rest mass (m 0) when plotting T versus m 0, and the mean transverse flow velocity from the slope of the mean transverse momentum (< {p}T> ) curve as a function of mean moving mass (\\overline{m}) when plotting < {p}T> versus \\overline{m}.
Computer-Assisted Classification Patterns in Autoimmune Diagnostics: The AIDA Project
Benammar Elgaaied, Amel; Cascio, Donato; Bruno, Salvatore; Ciaccio, Maria Cristina; Cipolla, Marco; Fauci, Alessandro; Morgante, Rossella; Taormina, Vincenzo; Gorgi, Yousr; Marrakchi Triki, Raja; Ben Ahmed, Melika; Louzir, Hechmi; Yalaoui, Sadok; Imene, Sfar; Issaoui, Yassine; Abidi, Ahmed; Ammar, Myriam; Bedhiafi, Walid; Ben Fraj, Oussama; Bouhaha, Rym; Hamdi, Khouloud; Soumaya, Koudhi; Neili, Bilel; Asma, Gati; Lucchese, Mariano; Catanzaro, Maria; Barbara, Vincenza; Brusca, Ignazio; Fregapane, Maria; Amato, Gaetano; Friscia, Giuseppe; Neila, Trai; Turkia, Souayeh; Youssra, Haouami; Rekik, Raja; Bouokez, Hayet; Vasile Simone, Maria; Fauci, Francesco; Raso, Giuseppe
2016-01-01
Antinuclear antibodies (ANAs) are significant biomarkers in the diagnosis of autoimmune diseases in humans, done by mean of Indirect ImmunoFluorescence (IIF) method, and performed by analyzing patterns and fluorescence intensity. This paper introduces the AIDA Project (autoimmunity: diagnosis assisted by computer) developed in the framework of an Italy-Tunisia cross-border cooperation and its preliminary results. A database of interpreted IIF images is being collected through the exchange of images and double reporting and a Gold Standard database, containing around 1000 double reported images, has been settled. The Gold Standard database is used for optimization of a CAD (Computer Aided Detection) solution and for the assessment of its added value, in order to be applied along with an Immunologist as a second Reader in detection of autoantibodies. This CAD system is able to identify on IIF images the fluorescence intensity and the fluorescence pattern. Preliminary results show that CAD, used as second Reader, appeared to perform better than Junior Immunologists and hence may significantly improve their efficacy; compared with two Junior Immunologists, the CAD system showed higher Intensity Accuracy (85,5% versus 66,0% and 66,0%), higher Patterns Accuracy (79,3% versus 48,0% and 66,2%), and higher Mean Class Accuracy (79,4% versus 56,7% and 64.2%). PMID:27042658
A quantitative literature-curated gold standard for kinase-substrate pairs
2011-01-01
We describe the Yeast Kinase Interaction Database (KID, http://www.moseslab.csb.utoronto.ca/KID/), which contains high- and low-throughput data relevant to phosphorylation events. KID includes 6,225 low-throughput and 21,990 high-throughput interactions, from greater than 35,000 experiments. By quantitatively integrating these data, we identified 517 high-confidence kinase-substrate pairs that we consider a gold standard. We show that this gold standard can be used to assess published high-throughput datasets, suggesting that it will enable similar rigorous assessments in the future. PMID:21492431
Criteria for Evaluating Interventions
ERIC Educational Resources Information Center
Miles, T. R.
2007-01-01
By common consent there is a "gold standard" in reference to which the efficacy of medical interventions needs to be evaluated. It is suggested in this paper that in educational research achievement of this gold standard is rarely possible. It does not follow, however, that research that falls short of this standard is therefore valueless; there…
40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the gold... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Gold Placer Mine Subcategory § 440.140 Applicability; description of the gold placer mine subcategory. (a) The...
Role of hydrogen ions in standard and activation heap leaching of gold
NASA Astrophysics Data System (ADS)
Rubtsov, YuI
2017-02-01
The role of hydrogen ions in activation heap leaching of gold from rebellious ore has been studied, which has allowed enhancing gold recovery. The author puts forward a gold leaching circuit with the use of activated oxygen-saturated solutions acidified to pH = 6-9.
Leishmania infection: laboratory diagnosing in the absence of a "gold standard".
Rodríguez-Cortés, Alhelí; Ojeda, Ana; Francino, Olga; López-Fuertes, Laura; Timón, Marcos; Alberola, Jordi
2010-02-01
There is no gold standard for diagnosing leishmaniases. Our aim was to assess the operative validity of tests used in detecting Leishmania infection using samples from experimental infections, a reliable equivalent to the classic definition of gold standard. Without statistical differences, the highest sensitivity was achieved by protein A (ProtA), immunoglobulin (Ig)G2, indirect fluorescenece antibody test (IFAT), lymphocyte proliferation assay, quantitative real-time polymerase chain reaction of bone marrow (qPCR-BM), qPCR-Blood, and IgG; and the highest specificity by IgG1, IgM, IgA, qPCR-Blood, IgG, IgG2, and qPCR-BM. Maximum positive predictive value was obtained simultaneously by IgG2, qPCR-Blood, and IgG; and maximum negative predictive value by qPCR-BM. Best positive and negative likelihood ratios were obtained by IgG2. The test having the greatest, statistically significant, area under the receiver operating characteristics curve was IgG2 enzyme-linked immunosorbent assay (ELISA). Thus, according to the gold standard used, IFAT and qPCR are far from fulfilling the requirements to be considered gold standards, and the test showing the highest potential to detect Leishmania infection is Leishmania-specific ELISA IgG2.
NASA Astrophysics Data System (ADS)
Brown, Bryan A.; Kloser, Matt
2009-12-01
We respond to Hwang and Kim and Yeo's critiques of the conceptual continuity framework in science education. First, we address the criticism that their analysis fails to recognize the situated perspective of learning by denying the dichotomy of the formal and informal knowledge as a starting point in the learning process. Second, we address the critique that students' descriptions fail to meet the "gold standard" of science education—alignment with an authoritative source and generalizability—by highlighting some student-expert congruence that could serve as the foundation for future learning. Third, we address the critique that a conceptual continuity framework could lead to less rigorous science education goals by arguing that the ultimate goals do not change, but rather that if the pathways that lead to the goals' achievement could recognize existing lexical continuities' science teaching may become more efficient. In sum, we argue that a conceptual continuities framework provides an asset, not deficit lexical perspective from which science teacher educators and science educators can begin to address and build complete science understandings.
Akolekar, Deepak B; Foran, Garry; Bhargava, Suresh K
2004-05-01
Au L(3)-edge X-ray absorption spectroscopic measurements were carried out over a series of mesoporous and microporous materials containing gold nanoparticles to investigate the effects of the host matrix and preparation methods on the properties of gold nanoparticles. The materials of structure type MCM-41, ZSM-5, SAPO-18 and LSX with varying framework composition containing low concentrations of gold nanoparticles were prepared and characterized. In these materials the size of the gold nanoparticles varied in the range approximately 1 to 4 nm. A series of gold nanoparticles within different mesoporous and microporous materials have been investigated using X-ray absorption fine structure (XANES, EXAFS) and other techniques. Information such as atomic distances, bonding and neighbouring environment obtained from XAFS measurements was useful in elucidating the nature and structure of gold nanoparticles on these catalytic materials. The influence of the high-temperature (823, 1113, 1273 K) treatment on gold nanoparticles inside the mesoporous matrix was investigated using the XAFS technique. The XAFS and XANES results confirm various characteristics of gold nanoparticles in these materials suitable for catalysis, fabrication of nanodevices and other applications.
The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing.
van Eijnatten, Maureen; Rijkhorst, Erik-Jan; Hofman, Mark; Forouzanfar, Tymour; Wolff, Jan
2016-01-01
Additively manufactured bone models, implants and drill guides are becoming increasingly popular amongst maxillofacial surgeons and dentists. To date, such constructs are commonly manufactured using CT technology that induces ionizing radiation. Recently, ultrashort echo time (UTE) MRI sequences have been developed that allow radiation-free imaging of facial bones. The aim of the present study was to assess the feasibility of UTE MRI sequences for medical additive manufacturing (AM). Three morphologically different dry human mandibles were scanned using a CT and MRI scanner. Additionally, optical scans of all three mandibles were made to acquire a "gold standard". All CT and MRI scans were converted into Standard Tessellation Language (STL) models and geometrically compared with the gold standard. To quantify the accuracy of the AM process, the CT, MRI and gold-standard STL models of one of the mandibles were additively manufactured, optically scanned and compared with the original gold-standard STL model. Geometric differences between all three CT-derived STL models and the gold standard were <1.0 mm. All three MRI-derived STL models generally presented deviations <1.5 mm in the symphyseal and mandibular area. The AM process introduced minor deviations of <0.5 mm. This study demonstrates that MRI using UTE sequences is a feasible alternative to CT in generating STL models of the mandible and would therefore be suitable for surgical planning and AM. Further in vivo studies are necessary to assess the usability of UTE MRI sequences in clinical settings.
NASA Astrophysics Data System (ADS)
Ingwersen, Wesley W.
Life cycle assessment (LCA) is an internationally standardized framework for assessing the environmental impacts of products that is rapidly evolving to improve understanding and quantification of how complex product systems depend upon and affect the environment. This dissertation contributes to that evolution through the development of new methods for measuring impacts, estimating the uncertainty of impacts, and measuring ranges of environmental performance, with a focus on product systems in non-OECD countries that have not been well characterized. The integration of a measure of total energy use, emergy, is demonstrated in an LCA of gold from the Yanacocha mine in Peru in the second chapter. A model for estimating the accuracy of emergy results is proposed in the following chapter. The fourth chapter presents a template for LCA-based quantification of the range of environmental performance for tropical agricultural products using the example of fresh pineapple production for export in Costa Rica that can be used to create product labels with environmental information. The final chapter synthesizes how each methodological contribution will together improve the science of measuring product environmental performance.
Methodological Pluralism: The Gold Standard of STEM Evaluation
ERIC Educational Resources Information Center
Lawrenz, Frances; Huffman, Douglas
2006-01-01
Nationally, there is continuing debate about appropriate methods for conducting educational evaluations. The U.S. Department of Education has placed a priority on "scientifically" based evaluation methods and has advocated a "gold standard" of randomized controlled experimentation. The priority suggests that randomized control methods are best,…
Advanced Placement and International Baccalaureate: Do They Deserve Gold Star Status?
ERIC Educational Resources Information Center
Byrd, Sheila
2007-01-01
For many people committed to strong academic standards, the "advanced" high school courses offered through the College Board's Advanced Placement program and, increasingly, the Diploma Programme of the International Baccalaureate Organisation (IBO) represent the curricular gold standard for secondary education. Admissions directors and…
Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito
2017-11-01
[Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.
2011-01-01
Background Verbal autopsy methods are critically important for evaluating the leading causes of death in populations without adequate vital registration systems. With a myriad of analytical and data collection approaches, it is essential to create a high quality validation dataset from different populations to evaluate comparative method performance and make recommendations for future verbal autopsy implementation. This study was undertaken to compile a set of strictly defined gold standard deaths for which verbal autopsies were collected to validate the accuracy of different methods of verbal autopsy cause of death assignment. Methods Data collection was implemented in six sites in four countries: Andhra Pradesh, India; Bohol, Philippines; Dar es Salaam, Tanzania; Mexico City, Mexico; Pemba Island, Tanzania; and Uttar Pradesh, India. The Population Health Metrics Research Consortium (PHMRC) developed stringent diagnostic criteria including laboratory, pathology, and medical imaging findings to identify gold standard deaths in health facilities as well as an enhanced verbal autopsy instrument based on World Health Organization (WHO) standards. A cause list was constructed based on the WHO Global Burden of Disease estimates of the leading causes of death, potential to identify unique signs and symptoms, and the likely existence of sufficient medical technology to ascertain gold standard cases. Blinded verbal autopsies were collected on all gold standard deaths. Results Over 12,000 verbal autopsies on deaths with gold standard diagnoses were collected (7,836 adults, 2,075 children, 1,629 neonates, and 1,002 stillbirths). Difficulties in finding sufficient cases to meet gold standard criteria as well as problems with misclassification for certain causes meant that the target list of causes for analysis was reduced to 34 for adults, 21 for children, and 10 for neonates, excluding stillbirths. To ensure strict independence for the validation of methods and assessment of comparative performance, 500 test-train datasets were created from the universe of cases, covering a range of cause-specific compositions. Conclusions This unique, robust validation dataset will allow scholars to evaluate the performance of different verbal autopsy analytic methods as well as instrument design. This dataset can be used to inform the implementation of verbal autopsies to more reliably ascertain cause of death in national health information systems. PMID:21816095
Site-Specific Attachment of gold Nanoparticles to DNA Templates
2001-01-01
1 -ethyl- 3 -( 3 - dimethylaminopropyl ) carbodiimide hydrochloride (Pierce) and -2.0rmg N...functionalized gold nanoparticles. The gold particles were covalently bound to the amino groups on the DNA using standard 1 -ethyl- 3 - ( 3 - dimethylaminopropyl ...nm). The reaction between the amino group on the DNA and the carboxyl group on the gold particle was facilitated by 1 -ethyl- 3 -( 3 - dimethylaminopropyl
Leishmania Infection: Laboratory Diagnosing in the Absence of a “Gold Standard”
Rodríguez-Cortés, Alhelí; Ojeda, Ana; Francino, Olga; López-Fuertes, Laura; Timón, Marcos; Alberola, Jordi
2010-01-01
There is no gold standard for diagnosing leishmaniases. Our aim was to assess the operative validity of tests used in detecting Leishmania infection using samples from experimental infections, a reliable equivalent to the classic definition of gold standard. Without statistical differences, the highest sensitivity was achieved by protein A (ProtA), immunoglobulin (Ig)G2, indirect fluorescenece antibody test (IFAT), lymphocyte proliferation assay, quantitative real-time polymerase chain reaction of bone marrow (qPCR-BM), qPCR-Blood, and IgG; and the highest specificity by IgG1, IgM, IgA, qPCR-Blood, IgG, IgG2, and qPCR-BM. Maximum positive predictive value was obtained simultaneously by IgG2, qPCR-Blood, and IgG; and maximum negative predictive value by qPCR-BM. Best positive and negative likelihood ratios were obtained by IgG2. The test having the greatest, statistically significant, area under the receiver operating characteristics curve was IgG2 enzyme-linked immunosorbent assay (ELISA). Thus, according to the gold standard used, IFAT and qPCR are far from fulfilling the requirements to be considered gold standards, and the test showing the highest potential to detect Leishmania infection is Leishmania-specific ELISA IgG2. PMID:20134001
Reddy, T.B.K.; Thomas, Alex D.; Stamatis, Dimitri; Bertsch, Jon; Isbandi, Michelle; Jansson, Jakob; Mallajosyula, Jyothi; Pagani, Ioanna; Lobos, Elizabeth A.; Kyrpides, Nikos C.
2015-01-01
The Genomes OnLine Database (GOLD; http://www.genomesonline.org) is a comprehensive online resource to catalog and monitor genetic studies worldwide. GOLD provides up-to-date status on complete and ongoing sequencing projects along with a broad array of curated metadata. Here we report version 5 (v.5) of the database. The newly designed database schema and web user interface supports several new features including the implementation of a four level (meta)genome project classification system and a simplified intuitive web interface to access reports and launch search tools. The database currently hosts information for about 19 200 studies, 56 000 Biosamples, 56 000 sequencing projects and 39 400 analysis projects. More than just a catalog of worldwide genome projects, GOLD is a manually curated, quality-controlled metadata warehouse. The problems encountered in integrating disparate and varying quality data into GOLD are briefly highlighted. GOLD fully supports and follows the Genomic Standards Consortium (GSC) Minimum Information standards. PMID:25348402
Decision-Assist and Closed-Loop Control of Fluid Therapy
2012-03-30
achieve target endpoints while reducing fluid needs in experimental models of hemorrhage. During the previous funding cycle, along with our... IABP ) (standard of care blood pressure monitor "gold standard") in cardiac surgical patients to blood pressure recorded by the WVSM. Rational for...WVSM vs Gold standard IABP 2) History of neuropraxia 3) Refusal to consent 4) Failure to obtain radial artery cannulation Ten CPB Patients were
Inspecting Cases against Revans' "Gold Standard" of Action Learning
ERIC Educational Resources Information Center
Willis, Verna J.
2004-01-01
A purposive sampling and analysis of ten case histories of action learning in the US suggests that applications tend to be partial, hierarchical, and leader controlled, thus running counter in several significant ways to the gold standard of Revans' action learning theory and egalitarian rules of engagement. Using critical markers to inspect the…
Seeking a Valid Gold Standard for an Innovative, Dialect-Neutral Language Test
ERIC Educational Resources Information Center
Pearson, Barbara Zurer; Jackson, Janice E.; Wu, Haotian
2014-01-01
Purpose: In this study, the authors explored alternative gold standards to validate an innovative, dialect-neutral language assessment. Method: Participants were 78 African American children, ages 5;0 (years;months) to 6;11. Twenty participants had previously been identified as having language impairment. The Diagnostic Evaluation of Language…
Reassessing RCTs as the "Gold Standard": Synergy Not Separatism in Evaluation Designs
ERIC Educational Resources Information Center
Hanley, Pam; Chambers, Bette; Haslam, Jonathan
2016-01-01
Randomised controlled trials (RCTs) are increasingly used to evaluate educational interventions in the UK. However, RCTs remain controversial for some elements of the research community. This paper argues that the widespread use of the term "gold standard" to describe RCTs is problematic, as it implies that other research methods are…
NAEP: Gold Standard or Fool's Gold?
ERIC Educational Resources Information Center
Popham, W. James
2005-01-01
Results of tests of students' skills and knowledge conducted by the National Assessment of Educational Progress (NAEP) and the state accountability tests required by the No Child Left Behind (NCLB) program should not be compared. The two tests are based on different standards and have different measurement functions and judging the results of one…
Currò, Vincenzo; Buonuomo, Paola Sabrina; Zambiano, Annaluce; Vituzzi, Andrea; Onesimo, Roberta; D'Atri, Alessandro
2007-01-01
The aim of this study is to verify the usefulness for parents of a web evaluation framework composed of ten quality criteria to improve their ability to assess the quality level of medical web sites. We conducted a randomised controlled trial that included two groups of parents who independently evaluated five paediatric web sites by filling out two distinct questionnaires: group A with the evaluation framework, group B without it. 40 volunteers were recruited from parents referring to the General Paediatrics Out-patients Department who satisfied the following eligibility criteria: Internet users, at least 1 child under 12 months old, no professional skill in Internet and medicine. The survey was taken between February 2, 2000 and March 22, 2000. Parents evaluated each web site and assigned a score, compared with a gold standard created by a group of experts. Suggesting evaluation criteria to parents seem useful for an improvement of their ability to evaluate web sites.
Patterning of oxide-hardened gold black by photolithography and metal lift-off
Deep Panjwani; Mehmet Yesiltas; Janardan Nath; D.E. Maukonen; Imen Rezadad; Evan M. Smith; R.E. Peale; Carol Hirschmugl; Julia Sedlmair; Ralf Wehlitz; Miriam Unger; Glenn Boreman
2014-01-01
A method to pattern infrared-absorbing gold black by conventional photolithography and lift-off is described. A photo-resist pattern is developed on a substrate by standard photolithography. Gold black is deposited over the whole by thermal evaporation in an inert gas at
Örtorp, Anders; Jemt, Torsten
2012-03-01
No long-term clinical studies covering more than 5 years are available on Computer Numeric Controlled (CNC) milled titanium frameworks. To evaluate and compare the clinical and radiographic performance of implant-supported prostheses provided with CNC titanium frameworks in the edentulous jaw with prostheses with cast gold-alloy frameworks during the first 10 years of function. Altogether, 126 edentulous patients were by random provided with 67 prostheses with titanium frameworks (test) in 23 maxillas and 44 mandibles, and with 62 prostheses with gold-alloy castings (control) in 31 maxillas and 31 mandibles. Clinical and radiographic 10-year data were collected for the groups and statistically compared on patient level. The 10-year prosthesis and implant cumulative survival rate was 95.6% compared with 98.3%, and 95.0% compared with 97.9% for test and control groups, respectively (p > .05). No implants were lost after 5 years of follow-up. Smokers lost more implants than nonsmokers after 5 years of follow-up (p < .01). Mean marginal bone loss in the test group was 0.7 mm (SD 0.61) and 0.7 mm (SD 0.85) in the maxilla and mandible, with similar pattern in the control group (p > .05), respectively. One prosthesis was lost in each group due to loss of implants, and one prosthesis failed due to framework fracture in the test group. Two metal fractures were registered in each group. More appointments of maintenance were needed for the prostheses in the maxilla compared with those in the mandible (p < .001). The frequency of complications was low with similar clinical and radiological performance for both groups during 10 years. CNC-milled titanium frameworks are a viable alternative to gold-alloy castings for restoring patients with implant-supported prostheses in the edentulous jaw. © 2009 Wiley Periodicals, Inc.
Zhang, Yi-Fan; Gou, Ling; Zhou, Tian-Shu; Lin, De-Nan; Zheng, Jing; Li, Ye; Li, Jing-Song
2017-08-01
Chronic diseases are complex and persistent clinical conditions that require close collaboration among patients and health care providers in the implementation of long-term and integrated care programs. However, current solutions focus partially on intensive interventions at hospitals rather than on continuous and personalized chronic disease management. This study aims to fill this gap by providing computerized clinical decision support during follow-up assessments of chronically ill patients at home. We proposed an ontology-based framework to integrate patient data, medical domain knowledge, and patient assessment criteria for chronic disease patient follow-up assessments. A clinical decision support system was developed to implement this framework for automatic selection and adaptation of standard assessment protocols to suit patient personal conditions. We evaluated our method in the case study of type 2 diabetic patient follow-up assessments. The proposed framework was instantiated using real data from 115,477 follow-up assessment records of 36,162 type 2 diabetic patients. Standard evaluation criteria were automatically selected and adapted to the particularities of each patient. Assessment results were generated as a general typing of patient overall condition and detailed scoring for each criterion, providing important indicators to the case manager about possible inappropriate judgments, in addition to raising patient awareness of their disease control outcomes. Using historical data as the gold standard, our system achieved a rate of accuracy of 99.93% and completeness of 95.00%. This study contributes to improving the accessibility, efficiency and quality of current patient follow-up services. It also provides a generic approach to knowledge sharing and reuse for patient-centered chronic disease management. Copyright © 2017 Elsevier Inc. All rights reserved.
Imperfect Gold Standards for Kidney Injury Biomarker Evaluation
Betensky, Rebecca A.; Emerson, Sarah C.; Bonventre, Joseph V.
2012-01-01
Clinicians have used serum creatinine in diagnostic testing for acute kidney injury for decades, despite its imperfect sensitivity and specificity. Novel tubular injury biomarkers may revolutionize the diagnosis of acute kidney injury; however, even if a novel tubular injury biomarker is 100% sensitive and 100% specific, it may appear inaccurate when using serum creatinine as the gold standard. Acute kidney injury, as defined by serum creatinine, may not reflect tubular injury, and the absence of changes in serum creatinine does not assure the absence of tubular injury. In general, the apparent diagnostic performance of a biomarker depends not only on its ability to detect injury, but also on disease prevalence and the sensitivity and specificity of the imperfect gold standard. Assuming that, at a certain cutoff value, serum creatinine is 80% sensitive and 90% specific and disease prevalence is 10%, a new perfect biomarker with a true 100% sensitivity may seem to have only 47% sensitivity compared with serum creatinine as the gold standard. Minimizing misclassification by using more strict criteria to diagnose acute kidney injury will reduce the error when evaluating the performance of a biomarker under investigation. Apparent diagnostic errors using a new biomarker may be a reflection of errors in the imperfect gold standard itself, rather than poor performance of the biomarker. The results of this study suggest that small changes in serum creatinine alone should not be used to define acute kidney injury in biomarker or interventional studies. PMID:22021710
NASA Astrophysics Data System (ADS)
Incerti, S.; Suerfu, B.; Xu, J.; Ivantchenko, V.; Mantero, A.; Brown, J. M. C.; Bernal, M. A.; Francis, Z.; Karamitros, M.; Tran, H. N.
2016-04-01
A revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.
The gene normalization task in BioCreative III
2011-01-01
Background We report the Gene Normalization (GN) challenge in BioCreative III where participating teams were asked to return a ranked list of identifiers of the genes detected in full-text articles. For training, 32 fully and 500 partially annotated articles were prepared. A total of 507 articles were selected as the test set. Due to the high annotation cost, it was not feasible to obtain gold-standard human annotations for all test articles. Instead, we developed an Expectation Maximization (EM) algorithm approach for choosing a small number of test articles for manual annotation that were most capable of differentiating team performance. Moreover, the same algorithm was subsequently used for inferring ground truth based solely on team submissions. We report team performance on both gold standard and inferred ground truth using a newly proposed metric called Threshold Average Precision (TAP-k). Results We received a total of 37 runs from 14 different teams for the task. When evaluated using the gold-standard annotations of the 50 articles, the highest TAP-k scores were 0.3297 (k=5), 0.3538 (k=10), and 0.3535 (k=20), respectively. Higher TAP-k scores of 0.4916 (k=5, 10, 20) were observed when evaluated using the inferred ground truth over the full test set. When combining team results using machine learning, the best composite system achieved TAP-k scores of 0.3707 (k=5), 0.4311 (k=10), and 0.4477 (k=20) on the gold standard, representing improvements of 12.4%, 21.8%, and 26.6% over the best team results, respectively. Conclusions By using full text and being species non-specific, the GN task in BioCreative III has moved closer to a real literature curation task than similar tasks in the past and presents additional challenges for the text mining community, as revealed in the overall team results. By evaluating teams using the gold standard, we show that the EM algorithm allows team submissions to be differentiated while keeping the manual annotation effort feasible. Using the inferred ground truth we show measures of comparative performance between teams. Finally, by comparing team rankings on gold standard vs. inferred ground truth, we further demonstrate that the inferred ground truth is as effective as the gold standard for detecting good team performance. PMID:22151901
The gene normalization task in BioCreative III.
Lu, Zhiyong; Kao, Hung-Yu; Wei, Chih-Hsuan; Huang, Minlie; Liu, Jingchen; Kuo, Cheng-Ju; Hsu, Chun-Nan; Tsai, Richard Tzong-Han; Dai, Hong-Jie; Okazaki, Naoaki; Cho, Han-Cheol; Gerner, Martin; Solt, Illes; Agarwal, Shashank; Liu, Feifan; Vishnyakova, Dina; Ruch, Patrick; Romacker, Martin; Rinaldi, Fabio; Bhattacharya, Sanmitra; Srinivasan, Padmini; Liu, Hongfang; Torii, Manabu; Matos, Sergio; Campos, David; Verspoor, Karin; Livingston, Kevin M; Wilbur, W John
2011-10-03
We report the Gene Normalization (GN) challenge in BioCreative III where participating teams were asked to return a ranked list of identifiers of the genes detected in full-text articles. For training, 32 fully and 500 partially annotated articles were prepared. A total of 507 articles were selected as the test set. Due to the high annotation cost, it was not feasible to obtain gold-standard human annotations for all test articles. Instead, we developed an Expectation Maximization (EM) algorithm approach for choosing a small number of test articles for manual annotation that were most capable of differentiating team performance. Moreover, the same algorithm was subsequently used for inferring ground truth based solely on team submissions. We report team performance on both gold standard and inferred ground truth using a newly proposed metric called Threshold Average Precision (TAP-k). We received a total of 37 runs from 14 different teams for the task. When evaluated using the gold-standard annotations of the 50 articles, the highest TAP-k scores were 0.3297 (k=5), 0.3538 (k=10), and 0.3535 (k=20), respectively. Higher TAP-k scores of 0.4916 (k=5, 10, 20) were observed when evaluated using the inferred ground truth over the full test set. When combining team results using machine learning, the best composite system achieved TAP-k scores of 0.3707 (k=5), 0.4311 (k=10), and 0.4477 (k=20) on the gold standard, representing improvements of 12.4%, 21.8%, and 26.6% over the best team results, respectively. By using full text and being species non-specific, the GN task in BioCreative III has moved closer to a real literature curation task than similar tasks in the past and presents additional challenges for the text mining community, as revealed in the overall team results. By evaluating teams using the gold standard, we show that the EM algorithm allows team submissions to be differentiated while keeping the manual annotation effort feasible. Using the inferred ground truth we show measures of comparative performance between teams. Finally, by comparing team rankings on gold standard vs. inferred ground truth, we further demonstrate that the inferred ground truth is as effective as the gold standard for detecting good team performance.
Wall, Matthew A; Harmsen, Stefan; Pal, Soumik; Zhang, Lihua; Arianna, Gianluca; Lombardi, John R; Drain, Charles Michael; Kircher, Moritz F
2017-06-01
Gold nanoparticles have unique properties that are highly dependent on their shape and size. Synthetic methods that enable precise control over nanoparticle morphology currently require shape-directing agents such as surfactants or polymers that force growth in a particular direction by adsorbing to specific crystal facets. These auxiliary reagents passivate the nanoparticles' surface, and thus decrease their performance in applications like catalysis and surface-enhanced Raman scattering. Here, a surfactant- and polymer-free approach to achieving high-performance gold nanoparticles is reported. A theoretical framework to elucidate the growth mechanism of nanoparticles in surfactant-free media is developed and it is applied to identify strategies for shape-controlled syntheses. Using the results of the analyses, a simple, green-chemistry synthesis of the four most commonly used morphologies: nanostars, nanospheres, nanorods, and nanoplates is designed. The nanoparticles synthesized by this method outperform analogous particles with surfactant and polymer coatings in both catalysis and surface-enhanced Raman scattering. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
40 CFR 63.11640 - Am I subject to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
...) National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production Area... subject to this subpart if you own or operate a gold mine ore processing and production facility as... source. The affected sources are each collection of “ore pretreatment processes” at a gold mine ore...
40 CFR 63.11640 - Am I subject to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
...) National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production Area... subject to this subpart if you own or operate a gold mine ore processing and production facility as... source. The affected sources are each collection of “ore pretreatment processes” at a gold mine ore...
40 CFR 63.11640 - Am I subject to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
...) National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production Area... subject to this subpart if you own or operate a gold mine ore processing and production facility as... source. The affected sources are each collection of “ore pretreatment processes” at a gold mine ore...
40 CFR 63.11640 - Am I subject to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
...) National Emission Standards for Hazardous Air Pollutants: Gold Mine Ore Processing and Production Area... subject to this subpart if you own or operate a gold mine ore processing and production facility as... source. The affected sources are each collection of “ore pretreatment processes” at a gold mine ore...
40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Gold... gold bearing ores from placer deposits; and (2) The beneficiation processes which use gravity... applicable to any mines or beneficiation processes which process less than 1500 cubic yards (cu yd) of ore...
The Trouble with the Gold Standard: School Libraries & Research
ERIC Educational Resources Information Center
Gordon, Carol
2007-01-01
Although science has provided empirical evidence for centuries, it's only as recently as the 1940s that a scientific method called randomized controlled trials (RCT) emerged as a technique to test the efficacy of drugs and medical procedures. Since RCT is unique in that it can claim causality, it's considered the "gold standard" of research…
Preschoolers Explore Greenhouses by Visiting a Greenhouse, Making a Model, and Growing Plants
ERIC Educational Resources Information Center
Perkins, Leann M.; Stoycheva, Dessy
2016-01-01
This practical lesson on greenhouses implements standards of the Next Generation Science Standards ("K-2 ETS I-2"; "K-LS1-1") and the preschool objectives from the Teaching Strategies GOLD. Teaching Strategies GOLD is an assessment tool available online and in print that can be used with any developmentally appropriate early…
Validating Automated Essay Scoring: A (Modest) Refinement of the "Gold Standard"
ERIC Educational Resources Information Center
Powers, Donald E.; Escoffery, David S.; Duchnowski, Matthew P.
2015-01-01
By far, the most frequently used method of validating (the interpretation and use of) automated essay scores has been to compare them with scores awarded by human raters. Although this practice is questionable, human-machine agreement is still often regarded as the "gold standard." Our objective was to refine this model and apply it to…
ERIC Educational Resources Information Center
Green, Debbie; Rosenfeld, Barry
2011-01-01
The Structured Interview of Reported Symptoms (SIRS; Rogers, Bagby, & Dickens, 1992) is often touted as the gold standard of measures of feigning. This label likely arises in part out of the impressive accuracy rates reported in the extensive validation research that preceded its publication. However, since its publication, researchers not only…
Genomes OnLine Database (GOLD) v.6: data updates and feature enhancements
Mukherjee, Supratim; Stamatis, Dimitri; Bertsch, Jon; Ovchinnikova, Galina; Verezemska, Olena; Isbandi, Michelle; Thomas, Alex D.; Ali, Rida; Sharma, Kaushal; Kyrpides, Nikos C.; Reddy, T. B. K.
2017-01-01
The Genomes Online Database (GOLD) (https://gold.jgi.doe.gov) is a manually curated data management system that catalogs sequencing projects with associated metadata from around the world. In the current version of GOLD (v.6), all projects are organized based on a four level classification system in the form of a Study, Organism (for isolates) or Biosample (for environmental samples), Sequencing Project and Analysis Project. Currently, GOLD provides information for 26 117 Studies, 239 100 Organisms, 15 887 Biosamples, 97 212 Sequencing Projects and 78 579 Analysis Projects. These are integrated with over 312 metadata fields from which 58 are controlled vocabularies with 2067 terms. The web interface facilitates submission of a diverse range of Sequencing Projects (such as isolate genome, single-cell genome, metagenome, metatranscriptome) and complex Analysis Projects (such as genome from metagenome, or combined assembly from multiple Sequencing Projects). GOLD provides a seamless interface with the Integrated Microbial Genomes (IMG) system and supports and promotes the Genomic Standards Consortium (GSC) Minimum Information standards. This paper describes the data updates and additional features added during the last two years. PMID:27794040
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reddy, Tatiparthi B. K.; Thomas, Alex D.; Stamatis, Dimitri
The Genomes OnLine Database (GOLD; http://www.genomesonline.org) is a comprehensive online resource to catalog and monitor genetic studies worldwide. GOLD provides up-to-date status on complete and ongoing sequencing projects along with a broad array of curated metadata. Within this paper, we report version 5 (v.5) of the database. The newly designed database schema and web user interface supports several new features including the implementation of a four level (meta)genome project classification system and a simplified intuitive web interface to access reports and launch search tools. The database currently hosts information for about 19 200 studies, 56 000 Biosamples, 56 000 sequencingmore » projects and 39 400 analysis projects. More than just a catalog of worldwide genome projects, GOLD is a manually curated, quality-controlled metadata warehouse. The problems encountered in integrating disparate and varying quality data into GOLD are briefly highlighted. Lastly, GOLD fully supports and follows the Genomic Standards Consortium (GSC) Minimum Information standards.« less
The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing
Rijkhorst, Erik-Jan; Hofman, Mark; Forouzanfar, Tymour; Wolff, Jan
2016-01-01
Objectives: Additively manufactured bone models, implants and drill guides are becoming increasingly popular amongst maxillofacial surgeons and dentists. To date, such constructs are commonly manufactured using CT technology that induces ionizing radiation. Recently, ultrashort echo time (UTE) MRI sequences have been developed that allow radiation-free imaging of facial bones. The aim of the present study was to assess the feasibility of UTE MRI sequences for medical additive manufacturing (AM). Methods: Three morphologically different dry human mandibles were scanned using a CT and MRI scanner. Additionally, optical scans of all three mandibles were made to acquire a “gold standard”. All CT and MRI scans were converted into Standard Tessellation Language (STL) models and geometrically compared with the gold standard. To quantify the accuracy of the AM process, the CT, MRI and gold-standard STL models of one of the mandibles were additively manufactured, optically scanned and compared with the original gold-standard STL model. Results: Geometric differences between all three CT-derived STL models and the gold standard were <1.0 mm. All three MRI-derived STL models generally presented deviations <1.5 mm in the symphyseal and mandibular area. The AM process introduced minor deviations of <0.5 mm. Conclusions: This study demonstrates that MRI using UTE sequences is a feasible alternative to CT in generating STL models of the mandible and would therefore be suitable for surgical planning and AM. Further in vivo studies are necessary to assess the usability of UTE MRI sequences in clinical settings. PMID:26943179
Relevance similarity: an alternative means to monitor information retrieval systems
Dong, Peng; Loh, Marie; Mondry, Adrian
2005-01-01
Background Relevance assessment is a major problem in the evaluation of information retrieval systems. The work presented here introduces a new parameter, "Relevance Similarity", for the measurement of the variation of relevance assessment. In a situation where individual assessment can be compared with a gold standard, this parameter is used to study the effect of such variation on the performance of a medical information retrieval system. In such a setting, Relevance Similarity is the ratio of assessors who rank a given document same as the gold standard over the total number of assessors in the group. Methods The study was carried out on a collection of Critically Appraised Topics (CATs). Twelve volunteers were divided into two groups of people according to their domain knowledge. They assessed the relevance of retrieved topics obtained by querying a meta-search engine with ten keywords related to medical science. Their assessments were compared to the gold standard assessment, and Relevance Similarities were calculated as the ratio of positive concordance with the gold standard for each topic. Results The similarity comparison among groups showed that a higher degree of agreements exists among evaluators with more subject knowledge. The performance of the retrieval system was not significantly different as a result of the variations in relevance assessment in this particular query set. Conclusion In assessment situations where evaluators can be compared to a gold standard, Relevance Similarity provides an alternative evaluation technique to the commonly used kappa scores, which may give paradoxically low scores in highly biased situations such as document repositories containing large quantities of relevant data. PMID:16029513
ERIC Educational Resources Information Center
Enlow, Robert C.
2008-01-01
In 2004, The Friedman Foundation for Educational Choice published a report titled "Grading Vouchers: Ranking America's School Choice Programs." Its purpose was to measure every existing school choice program against the gold standard set by Milton and Rose Friedman: that the most effective way to improve K-12 education and thus ensure a stable…
Huber, J; Hüsler, J; Dieppe, P; Günther, K P; Dreinhöfer, K; Judge, A
2016-03-01
To validate a new method to identify responders (relative effect per patient (REPP) >0.2) using the OMERACT-OARSI criteria as gold standard in a large multicentre sample. The REPP ([score before - after treatment]/score before treatment) was calculated for 845 patients of a large multicenter European cohort study for THR. The patients with a REPP >0.2 were defined as responders. The responder rate was compared to the gold standard (OMERACT-OARSI criteria) using receiver operator characteristic (ROC) curve analysis for sensitivity, specificity and percentage of appropriately classified patients. With the criterion REPP>0.2 85.4% of the patients were classified as responders, applying the OARSI-OMERACT criteria 85.7%. The new method had 98.8% sensitivity, 94.2% specificity and 98.1% of the patients were correctly classified compared to the gold standard. The external validation showed a high sensitivity and also specificity of a new criterion to identify a responder compared to the gold standard method. It is simple and has no uncertainties due to a single classification criterion. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
A framework for the meta-analysis of Bland-Altman studies based on a limits of agreement approach.
Tipton, Elizabeth; Shuster, Jonathan
2017-10-15
Bland-Altman method comparison studies are common in the medical sciences and are used to compare a new measure to a gold-standard (often costlier or more invasive) measure. The distribution of these differences is summarized by two statistics, the 'bias' and standard deviation, and these measures are combined to provide estimates of the limits of agreement (LoA). When these LoA are within the bounds of clinically insignificant differences, the new non-invasive measure is preferred. Very often, multiple Bland-Altman studies have been conducted comparing the same two measures, and random-effects meta-analysis provides a means to pool these estimates. We provide a framework for the meta-analysis of Bland-Altman studies, including methods for estimating the LoA and measures of uncertainty (i.e., confidence intervals). Importantly, these LoA are likely to be wider than those typically reported in Bland-Altman meta-analyses. Frequently, Bland-Altman studies report results based on repeated measures designs but do not properly adjust for this design in the analysis. Meta-analyses of Bland-Altman studies frequently exclude these studies for this reason. We provide a meta-analytic approach that allows inclusion of estimates from these studies. This includes adjustments to the estimate of the standard deviation and a method for pooling the estimates based upon robust variance estimation. An example is included based on a previously published meta-analysis. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
A pneumatic Bionic Voice prosthesis-Pre-clinical trials of controlling the voice onset and offset.
Ahmadi, Farzaneh; Noorian, Farzad; Novakovic, Daniel; van Schaik, André
2018-01-01
Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech.
A pneumatic Bionic Voice prosthesis—Pre-clinical trials of controlling the voice onset and offset
Noorian, Farzad; Novakovic, Daniel; van Schaik, André
2018-01-01
Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech. PMID:29466455
Incerti, S.; Suerfu, B.; Xu, J.; ...
2016-02-16
We report that a revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research andmore » other low energy physics fields.« less
True versus Apparent Malaria Infection Prevalence: The Contribution of a Bayesian Approach
Claes, Filip; Van Hong, Nguyen; Torres, Kathy; Mao, Sokny; Van den Eede, Peter; Thi Thinh, Ta; Gamboa, Dioni; Sochantha, Tho; Thang, Ngo Duc; Coosemans, Marc; Büscher, Philippe; D'Alessandro, Umberto; Berkvens, Dirk; Erhart, Annette
2011-01-01
Aims To present a new approach for estimating the “true prevalence” of malaria and apply it to datasets from Peru, Vietnam, and Cambodia. Methods Bayesian models were developed for estimating both the malaria prevalence using different diagnostic tests (microscopy, PCR & ELISA), without the need of a gold standard, and the tests' characteristics. Several sources of information, i.e. data, expert opinions and other sources of knowledge can be integrated into the model. This approach resulting in an optimal and harmonized estimate of malaria infection prevalence, with no conflict between the different sources of information, was tested on data from Peru, Vietnam and Cambodia. Results Malaria sero-prevalence was relatively low in all sites, with ELISA showing the highest estimates. The sensitivity of microscopy and ELISA were statistically lower in Vietnam than in the other sites. Similarly, the specificities of microscopy, ELISA and PCR were significantly lower in Vietnam than in the other sites. In Vietnam and Peru, microscopy was closer to the “true” estimate than the other 2 tests while as expected ELISA, with its lower specificity, usually overestimated the prevalence. Conclusions Bayesian methods are useful for analyzing prevalence results when no gold standard diagnostic test is available. Though some results are expected, e.g. PCR more sensitive than microscopy, a standardized and context-independent quantification of the diagnostic tests' characteristics (sensitivity and specificity) and the underlying malaria prevalence may be useful for comparing different sites. Indeed, the use of a single diagnostic technique could strongly bias the prevalence estimation. This limitation can be circumvented by using a Bayesian framework taking into account the imperfect characteristics of the currently available diagnostic tests. As discussed in the paper, this approach may further support global malaria burden estimation initiatives. PMID:21364745
Krupp, Sonja; Kasper, Jennifer; Balck, Friedrich; Schnoor, Maike; Eisemann, Nora; Lohse, Kristina; Brunk, Juliane; Katalinic, Alexander; Willkomm, Martin
2015-02-01
Although many activities depend on intact fine motor skills no standardized assessment has been broadly established. The 20 cents test (20-C-T) was developed in 2009 and takes less than 5 mins. The quality criteria were investigated within the framework of this study. A total of 300 geriatric patients participated in the study. The classification of occupational therapists based on standardized anamnesis and clinical examination served as the gold standard. Physiotherapists blinded to the study particulars applied the 20-C-T. Every fourth patient suffered from deficits in fine motor skills relevant to everyday life. The 20-C-T correlated with the clinical severity level and was also feasible for patients with intermediate impairment of cognition or vision. Handedness, age and sex were without significant influence. Intrarater and interrater reliability were good. Standardized testing of fine motor skills should be included in geriatric screening and basic assessment. The quality criteria of the 20-C-T show that it can be used for this purpose. Further diagnostic steps are recommended whenever a geriatric patient needs more than 40 s for the task.
40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE... that produce gold or gold bearing ores from placer deposits; and (2) The beneficiation processes which... yards (cu yd) of ore per year, or to dredges which process less than 50,000 cu yd of ore per year, or to...
40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE... that produce gold or gold bearing ores from placer deposits; and (2) The beneficiation processes which... yards (cu yd) of ore per year, or to dredges which process less than 50,000 cu yd of ore per year, or to...
40 CFR 440.140 - Applicability; description of the gold placer mine subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE... that produce gold or gold bearing ores from placer deposits; and (2) The beneficiation processes which... yards (cu yd) of ore per year, or to dredges which process less than 50,000 cu yd of ore per year, or to...
NASA Astrophysics Data System (ADS)
Arif, J.; Baker, T.
2004-10-01
Gold is an important by-product in many porphyry-type deposits but the distribution and chemistry of gold in such systems remains poorly understood. Here we report the results of petrographic, electron microprobe, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), and flotation test studies of gold and associated copper sulfides within a paragenetic framework from the world-class Batu Hijau (914 mt @ 0.53% Cu, 0.40 g/t Au) porphyry copper gold deposit, Indonesia. Unlike many other porphyry copper gold deposits, early copper minerals (bornite digenite chalcocite) are well preserved at Batu Hijau and the chalcopyrite pyrite overprint is less developed. Hence, it provides an excellent opportunity to study the entire gold paragenesis of the porphyry system. In 105 polished thin sections, 699 native gold grains were identified. Almost all of the native gold grains occurred either within quartz veins, attached to sulfide, or as free gold along quartz or silicate grain boundaries. The native gold grains are dominantly round in shape and mostly 1 12 μm in size. The majority of gold was deposited during the formation of early ‘A’ veins and is dominantly associated with bornite rather than chalcopyrite. The petrographic and LA-ICP-MS study results indicate that in bornite-rich ores gold mostly occurs within copper sulfide grains as invisible gold (i.e., within the sulfide structure) or as native gold grains. In chalcopyrite-rich ores gold mostly occurs as native gold grains with lesser invisible gold. Petrographic observations also indicate a higher proportion of free gold (native gold not attached to any sulfide) in chalcopyrite-rich ores compared to bornite rich ores. The pattern of free gold distribution appears to correlate with the flotation test data, where the average gold recovery value from chalcopyrite-rich ores is consistently lower than bornite-rich ores. Our data suggest that porphyry copper-gold deposits with chalcopyrite-rich ores are more likely to have a higher proportion of free gold and may require different ore processing strategies.
Integrated risk framework for onsite wastewater treatment systems.
Carroll, Steven; Goonetilleke, Ashantha; Thomas, Evan; Hargreaves, Megan; Frost, Ray; Dawes, Les
2006-08-01
Onsite wastewater treatment systems (OWTS) are becoming increasingly important for the treatment and dispersal of effluent in new urbanised developments that are not serviced by centralised wastewater collection and treatment systems. However, the current standards and guidelines adopted by many local authorities for assessing suitable site and soil conditions for OWTS are increasingly coming under scrutiny due to the public health and environmental impacts caused by poorly performing systems, in particular septic tank-soil adsorption systems. In order to achieve sustainable onsite wastewater treatment with minimal impacts on the environment and public health, more appropriate means of assessment are required. This paper highlights an integrated risk based approach for assessing the inherent hazards associated with OWTS in order to manage and mitigate the environmental and public health risks inherent with onsite wastewater treatment. In developing a sound and cohesive integrated risk framework for OWTS, several key issues must be recognised. These include the inclusion of relevant stakeholders throughout framework development, the integration of scientific knowledge, data and analysis with risk assessment and management ideals, and identification of the appropriate performance goals for successful management and mitigation of associated risks. These issues were addressed in the development of the risk framework to provide a generic approach to assessing risk from OWTS. The utilisation of the developed risk framework for achieving more appropriate assessment and management techniques for OWTS is presented in a case study for the Gold Coast region, Queensland State, Australia.
Integrated Risk Framework for Onsite Wastewater Treatment Systems
NASA Astrophysics Data System (ADS)
Carroll, Steven; Goonetilleke, Ashantha; Thomas, Evan; Hargreaves, Megan; Frost, Ray; Dawes, Les
2006-08-01
Onsite wastewater treatment systems (OWTS) are becoming increasingly important for the treatment and dispersal of effluent in new urbanised developments that are not serviced by centralised wastewater collection and treatment systems. However, the current standards and guidelines adopted by many local authorities for assessing suitable site and soil conditions for OWTS are increasingly coming under scrutiny due to the public health and environmental impacts caused by poorly performing systems, in particular septic tank-soil adsorption systems. In order to achieve sustainable onsite wastewater treatment with minimal impacts on the environment and public health, more appropriate means of assessment are required. This paper highlights an integrated risk based approach for assessing the inherent hazards associated with OWTS in order to manage and mitigate the environmental and public health risks inherent with onsite wastewater treatment. In developing a sound and cohesive integrated risk framework for OWTS, several key issues must be recognised. These include the inclusion of relevant stakeholders throughout framework development, the integration of scientific knowledge, data and analysis with risk assessment and management ideals, and identification of the appropriate performance goals for successful management and mitigation of associated risks. These issues were addressed in the development of the risk framework to provide a generic approach to assessing risk from OWTS. The utilisation of the developed risk framework for achieving more appropriate assessment and management techniques for OWTS is presented in a case study for the Gold Coast region, Queensland State, Australia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juang, T; Bush, K; Loo, B
Purpose: We propose a workflow to improve access to stereotactic ablative radiation therapy (SABR) for rural patients. When implemented, a separate trip to the central facility for simulation can be eliminated. Two elements are required: (1) Fabrication of custom immobilization devices to match positioning on prior diagnostic CT (dxCT). (2) Remote radiation pre-planning on dxCT, with transfer of contours/plan to simulation CT (simCT) and initiation of treatment same-day or next day. In this retrospective study, we validated part 2 of the workflow using patients already treated with SABR for upper lobe lung tumors. Methods: Target/normal structures were contoured on dxCT;more » a plan was created and approved by the physician. Structures were transferred to simCT using deformable image registration and the plan was re-optimized on simCT. Plan quality was evaluated through comparison to gold-standard structures contoured on simCT and a gold-standard plan based on these structures. Workflow-generated plan quality in this study represents a worst-case scenario as these patients were not treated using custom immobilization to match dxCT position as would be done when the workflow is implemented clinically. Results: 5/6 plans created through the pre-planning workflow were clinically acceptable. For all six plans, the gold-standard GTV received full prescription dose, along with median PTV V95%=95.2% and median PTV D95%=95.4%. Median GTV DSC=0.80, indicating high degree of similarity between the deformed and gold-standard GTV contours despite small GTV sizes (mean=3.0cc). One outlier (DSC=0.49) resulted in inadequate PTV coverage (V95%=62.9%) in the workflow plan; in clinical practice, this mismatch between deformed/gold-standard GTV would be revised by the physician after deformable registration. For all patients, normal tissue doses were comparable to the gold-standard plan and well within constraints. Conclusion: Pre-planning SABR cases on diagnostic imaging generated clinically acceptable plans. Coupled with rapid-prototyped custom immobilization, this workflow may improve treatment access for rural patients.« less
Ortorp, A; Linden, B; Jemt, T
1999-01-01
The purpose of this study was to report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks and to compare their performance with that of prostheses provided with conventional cast frameworks. On a routine basis, a consecutive group of 824 edentulous patients were provided with fixed prostheses supported by implants in the edentulous mandible. In addition to conventional gold-alloy castings, patients were at random provided with 2 kinds of laser-welded titanium frameworks. In all, 155 patients were included in the 2 titanium framework groups. A control group of 53 randomly selected patients with conventional gold-alloy castings was used for comparison. Clinical and radiographic 5-year data was collected for the 3 groups. All followed patients still had fixed prostheses in the mandible after 5 years. The overall cumulative success rates were 95.9% and 99.7% for titanium-framework prostheses and implants, respectively. The corresponding success rates for the control group were 100% and 99.6%, respectively. Bone loss was 0.5 mm on average during the 5-year follow-up period. The most common complications for titanium frameworks were resin or tooth fractures, gingival inflammation, and fractures of the metal frames (10%). One of the cast frameworks fractured and was resoldered. Loose and fractured implant screw components were few (< 1%). Even though the cast frameworks had a higher success rate, the overall titanium framework treatment result was well in accordance with the result of the control group. The test groups performed better after clinicians had gained some experience with the technique, and laser-welded titanium frameworks seem to be a viable alternative to conventional castings in the edentulous mandible.
Tilgner, Dominic; Kempe, Rhett
2017-03-02
Porous coordination polymers (PCP) or metal- organic frameworks (MOF) are promising materials for the generation of photocatalytically active composite materials. Here, a novel synthesis concept is reported, which permits the formation of PCP/MOF-core-Au/anatase-shell materials. These materials are photocatalysts for wastewater purification and hydrogen generation from water under visible-light illumination. MIL-101 (Cr) is utilized as the core material, which directs the size of the core-shell compound and ensures the overall stability. In addition, its excellent reversible large molecule sorption behavior allows the materials synthesis. The crystalline anatase shell is generated stepwise under mild conditions using titanium(IV) isopropoxide as a precursor. The high degree of control of the vapor phase deposition process permits the precise anatase shell formation. The generation of plasmonic active gold particles on the TiO 2 shell leads to an efficient material for visible-light-driven photocatalysis with a higher activity than gold-decorated P25 (Degussa). © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Seeking a valid gold standard for an innovative, dialect-neutral language test.
Pearson, Barbara Zurer; Jackson, Janice E; Wu, Haotian
2014-04-01
PURPOSE In this study, the authors explored alternative gold standards to validate an innovative, dialect-neutral language assessment. METHOD Participants were 78 African American children, ages 5;0 (years;months) to 6;11. Twenty participants had previously been identified as having language impairment. The Diagnostic Evaluation of Language Variation-Norm Referenced (DELV-NR; Seymour, Roeper, & J. de Villiers, 2005) was administered, and concurrent language samples (LSs) were collected. Using LS profiles as the gold standard, sensitivity, specificity, and other measures of diagnostic accuracy were compared for diagnoses made from the DELV-NR and participants' clinical status prior to recruitment. In a second analysis, the authors used results from the first analysis to make evidence-based adjustments in the estimates of DELV-NR diagnostic accuracy. RESULTS Accuracy of the DELV-NR relative to LS profiles was greater than that of prior diagnoses, indicating that the DELV-NR was an improvement over preexisting diagnoses for this group. Specificity met conventional standards, but sensitivity was somewhat low. Reanalysis using the positive and negative predictive power of the preexisting diagnosis in a discrepant-resolution procedure revealed that estimates for sensitivity and specificity for the DELV-NR were .85 and .93, respectively. CONCLUSION The authors found that, even after making allowances for the imperfection of available gold standards, clinical decisions made with the DELV-NR achieved high values on conventional measures of diagnostic accuracy.
Bias in estimating accuracy of a binary screening test with differential disease verification
Brinton, John T.; Ringham, Brandy M.; Glueck, Deborah H.
2011-01-01
SUMMARY Sensitivity, specificity, positive and negative predictive value are typically used to quantify the accuracy of a binary screening test. In some studies it may not be ethical or feasible to obtain definitive disease ascertainment for all subjects using a gold standard test. When a gold standard test cannot be used an imperfect reference test that is less than 100% sensitive and specific may be used instead. In breast cancer screening, for example, follow-up for cancer diagnosis is used as an imperfect reference test for women where it is not possible to obtain gold standard results. This incomplete ascertainment of true disease, or differential disease verification, can result in biased estimates of accuracy. In this paper, we derive the apparent accuracy values for studies subject to differential verification. We determine how the bias is affected by the accuracy of the imperfect reference test, the percent who receive the imperfect reference standard test not receiving the gold standard, the prevalence of the disease, and the correlation between the results for the screening test and the imperfect reference test. It is shown that designs with differential disease verification can yield biased estimates of accuracy. Estimates of sensitivity in cancer screening trials may be substantially biased. However, careful design decisions, including selection of the imperfect reference test, can help to minimize bias. A hypothetical breast cancer screening study is used to illustrate the problem. PMID:21495059
A multilingual gold-standard corpus for biomedical concept recognition: the Mantra GSC
Clematide, Simon; Akhondi, Saber A; van Mulligen, Erik M; Rebholz-Schuhmann, Dietrich
2015-01-01
Objective To create a multilingual gold-standard corpus for biomedical concept recognition. Materials and methods We selected text units from different parallel corpora (Medline abstract titles, drug labels, biomedical patent claims) in English, French, German, Spanish, and Dutch. Three annotators per language independently annotated the biomedical concepts, based on a subset of the Unified Medical Language System and covering a wide range of semantic groups. To reduce the annotation workload, automatically generated preannotations were provided. Individual annotations were automatically harmonized and then adjudicated, and cross-language consistency checks were carried out to arrive at the final annotations. Results The number of final annotations was 5530. Inter-annotator agreement scores indicate good agreement (median F-score 0.79), and are similar to those between individual annotators and the gold standard. The automatically generated harmonized annotation set for each language performed equally well as the best annotator for that language. Discussion The use of automatic preannotations, harmonized annotations, and parallel corpora helped to keep the manual annotation efforts manageable. The inter-annotator agreement scores provide a reference standard for gauging the performance of automatic annotation techniques. Conclusion To our knowledge, this is the first gold-standard corpus for biomedical concept recognition in languages other than English. Other distinguishing features are the wide variety of semantic groups that are being covered, and the diversity of text genres that were annotated. PMID:25948699
Menezes, Ana M; Wehrmeister, Fernando C; Perez-Padilla, Rogelio; Viana, Karynna P; Soares, Claudia; Müllerova, Hana; Valdivia, Gonzalo; Jardim, José R; Montes de Oca, Maria
2017-01-01
The Global Initiative for Chronic Obstructive Lung Disease (GOLD) report provides a framework for classifying COPD reflecting the impacts of disease on patients and for targeting treatment recommendations. The GOLD 2017 introduced a new classification with 16 subgroups based on a composite of spirometry and symptoms/exacerbations. Data from the population-based PLATINO study, collected at baseline and at follow-up, in three sites in Latin America were analyzed to compare the following: 1) the distribution of COPD patients according to GOLD 2007, 2013, and 2017; 2) the stability of the 2007 and 2013 classifications; and 3) the mortality rate over time stratified by GOLD 2007, 2013, and 2017. Of the 524 COPD patients evaluated, most of them were classified as Grade I or II (GOLD 2007) and Group A or B (GOLD 2013), with ≈70% of those classified as Group A in GOLD 2013 also classified as Grade I in GOLD 2007 and the highest percentage (41%) in Group D (2013) classified as Grade III (2007). According to GOLD 2017, among patients with Grade I airflow limitation, 69% of them were categorized into Group A, whereas Grade IV patients were more evenly distributed among Groups A-D. Most of the patients classified by GOLD 2007 remained in the same airflow limitation group at the follow-up; a greater temporal variability was observed with GOLD 2013 classification. Incidence-mortality rate in patients classified by GOLD 2007 was positively associated with increasing severity of airflow obstruction; for GOLD 2013 and GOLD 2017 (Groups A-D), highest mortality rates were observed in Groups C and D. No clear pattern was observed for mortality across the GOLD 2017 subgroups. The PLATINO study data suggest that GOLD 2007 classification shows more stability over time compared with GOLD 2013. No clear patterns with respect to the distribution of patients or incidence-mortality rates were observed according to GOLD 2013/2017 classification.
A consensus-based gold standard for the evaluation of mass casualty triage systems.
Lerner, E Brooke; McKee, Courtney H; Cady, Charles E; Cone, David C; Colella, M Riccardo; Cooper, Arthur; Coule, Phillip L; Lairet, Julio R; Liu, J Marc; Pirrallo, Ronald G; Sasser, Scott M; Schwartz, Richard; Shepherd, Greene; Swienton, Raymond E
2015-01-01
Accuracy and effectiveness analyses of mass casualty triage systems are limited because there are no gold standard definitions for each of the triage categories. Until there is agreement on which patients should be identified by each triage category, it will be impossible to calculate sensitivity and specificity or to compare accuracy between triage systems. To develop a consensus-based, functional gold standard definition for each mass casualty triage category. National experts were recruited through the lead investigators' contacts and their suggested contacts. Key informant interviews were conducted to develop a list of potential criteria for defining each triage category. Panelists were interviewed in order of their availability until redundancy of themes was achieved. Panelists were blinded to each other's responses during the interviews. A modified Delphi survey was developed with the potential criteria identified during the interview and delivered to all recruited experts. In the early rounds, panelists could add, remove, or modify criteria. In the final rounds edits were made to the criteria until at least 80% agreement was achieved. Thirteen national and local experts were recruited to participate in the project. Six interviews were conducted. Three rounds of voting were performed, with 12 panelists participating in the first round, 12 in the second round, and 13 in the third round. After the first two rounds, the criteria were modified according to respondent suggestions. In the final round, over 90% agreement was achieved for all but one criterion. A single e-mail vote was conducted on edits to the final criterion and consensus was achieved. A consensus-based, functional gold standard definition for each mass casualty triage category was developed. These gold standard definitions can be used to evaluate the accuracy of mass casualty triage systems after an actual incident, during training, or for research.
ERIC Educational Resources Information Center
Winterbottom, Christian; Jones, Ithel
2014-01-01
This article reports on the first Florida statewide assessment of the Gold Seal Quality Care program, accreditation, and the relationship with licensing violations. This study analyzed the differences between the Department of Children and Families Gold Seal-Accredited facilities and nonaccredited facilities by comparing the facilities and the…
USDA-ARS?s Scientific Manuscript database
Huckleberry Gold is a purple skinned, yellow fleshed fresh market cultivar with similar culinary qualities to the market standard Yukon Gold. It has lower specific gravity, sucrose and vitamin C content, but a significantly higher level of antioxidants. Notable disease resistant characteristics are ...
Artisanal and Small-Scale Gold Mining Without Mercury
Mercury-free techniques are safer for miners, their families and local communities. They can also help miners qualify for certification under fair-mined standards, potentially allowing them to market their gold at higher prices.
Jani, Kalpesh; Rajan, P S; Sendhilkumar, K; Palanivelu, C
2006-06-01
This review article is a tribute to the genius of Professor Erich Muhe, a man ahead of his times. We trace the development of laparoscopic cholecystectomy and detail the tribulations faced by Muhe. On the occasion of the twentieth anniversary of the first laparoscopic cholecystectomy, we take another look at some of the controversies surrounding this gold standard in the management of gallbladder disease.
Durão, Solange; Kredo, Tamara; Volmink, Jimmy
2015-06-01
To develop, assess, and maximize the sensitivity of a search strategy to identify diet and nutrition trials in PubMed using relative recall. We developed a search strategy to identify diet and nutrition trials in PubMed. We then constructed a gold standard reference set to validate the identified trials using the relative recall method. Relative recall was calculated by dividing the number of references from the gold standard our search strategy identified by the total number of references in the gold standard. Our gold standard comprised 298 trials, derived from 16 included systematic reviews. The initial search strategy identified 242 of 298 references, with a relative recall of 81.2% [95% confidence interval (CI): 76.3%, 85.5%]. We analyzed titles and abstracts of the 56 missed references for possible additional terms. We then modified the search strategy accordingly. The relative recall of the final search strategy was 88.6% (95% CI: 84.4%, 91.9%). We developed a search strategy to identify diet and nutrition trials in PubMed with a high relative recall (sensitivity). This could be useful for establishing a nutrition trials register to support the conduct of future research, including systematic reviews. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Building an Evaluation Scale using Item Response Theory.
Lalor, John P; Wu, Hao; Yu, Hong
2016-11-01
Evaluation of NLP methods requires testing against a previously vetted gold-standard test set and reporting standard metrics (accuracy/precision/recall/F1). The current assumption is that all items in a given test set are equal with regards to difficulty and discriminating power. We propose Item Response Theory (IRT) from psychometrics as an alternative means for gold-standard test-set generation and NLP system evaluation. IRT is able to describe characteristics of individual items - their difficulty and discriminating power - and can account for these characteristics in its estimation of human intelligence or ability for an NLP task. In this paper, we demonstrate IRT by generating a gold-standard test set for Recognizing Textual Entailment. By collecting a large number of human responses and fitting our IRT model, we show that our IRT model compares NLP systems with the performance in a human population and is able to provide more insight into system performance than standard evaluation metrics. We show that a high accuracy score does not always imply a high IRT score, which depends on the item characteristics and the response pattern.
Building an Evaluation Scale using Item Response Theory
Lalor, John P.; Wu, Hao; Yu, Hong
2016-01-01
Evaluation of NLP methods requires testing against a previously vetted gold-standard test set and reporting standard metrics (accuracy/precision/recall/F1). The current assumption is that all items in a given test set are equal with regards to difficulty and discriminating power. We propose Item Response Theory (IRT) from psychometrics as an alternative means for gold-standard test-set generation and NLP system evaluation. IRT is able to describe characteristics of individual items - their difficulty and discriminating power - and can account for these characteristics in its estimation of human intelligence or ability for an NLP task. In this paper, we demonstrate IRT by generating a gold-standard test set for Recognizing Textual Entailment. By collecting a large number of human responses and fitting our IRT model, we show that our IRT model compares NLP systems with the performance in a human population and is able to provide more insight into system performance than standard evaluation metrics. We show that a high accuracy score does not always imply a high IRT score, which depends on the item characteristics and the response pattern.1 PMID:28004039
Hong, Na; Li, Dingcheng; Yu, Yue; Xiu, Qiongying; Liu, Hongfang; Jiang, Guoqian
2016-10-01
Constructing standard and computable clinical diagnostic criteria is an important but challenging research field in the clinical informatics community. The Quality Data Model (QDM) is emerging as a promising information model for standardizing clinical diagnostic criteria. To develop and evaluate automated methods for converting textual clinical diagnostic criteria in a structured format using QDM. We used a clinical Natural Language Processing (NLP) tool known as cTAKES to detect sentences and annotate events in diagnostic criteria. We developed a rule-based approach for assigning the QDM datatype(s) to an individual criterion, whereas we invoked a machine learning algorithm based on the Conditional Random Fields (CRFs) for annotating attributes belonging to each particular QDM datatype. We manually developed an annotated corpus as the gold standard and used standard measures (precision, recall and f-measure) for the performance evaluation. We harvested 267 individual criteria with the datatypes of Symptom and Laboratory Test from 63 textual diagnostic criteria. We manually annotated attributes and values in 142 individual Laboratory Test criteria. The average performance of our rule-based approach was 0.84 of precision, 0.86 of recall, and 0.85 of f-measure; the performance of CRFs-based classification was 0.95 of precision, 0.88 of recall and 0.91 of f-measure. We also implemented a web-based tool that automatically translates textual Laboratory Test criteria into the QDM XML template format. The results indicated that our approaches leveraging cTAKES and CRFs are effective in facilitating diagnostic criteria annotation and classification. Our NLP-based computational framework is a feasible and useful solution in developing diagnostic criteria representation and computerization. Copyright © 2016 Elsevier Inc. All rights reserved.
Evaluating the evaluation of cancer driver genes
Tokheim, Collin J.; Papadopoulos, Nickolas; Kinzler, Kenneth W.; Vogelstein, Bert; Karchin, Rachel
2016-01-01
Sequencing has identified millions of somatic mutations in human cancers, but distinguishing cancer driver genes remains a major challenge. Numerous methods have been developed to identify driver genes, but evaluation of the performance of these methods is hindered by the lack of a gold standard, that is, bona fide driver gene mutations. Here, we establish an evaluation framework that can be applied to driver gene prediction methods. We used this framework to compare the performance of eight such methods. One of these methods, described here, incorporated a machine-learning–based ratiometric approach. We show that the driver genes predicted by each of the eight methods vary widely. Moreover, the P values reported by several of the methods were inconsistent with the uniform values expected, thus calling into question the assumptions that were used to generate them. Finally, we evaluated the potential effects of unexplained variability in mutation rates on false-positive driver gene predictions. Our analysis points to the strengths and weaknesses of each of the currently available methods and offers guidance for improving them in the future. PMID:27911828
Fact Sheet - Final Air Toxics Rule for Gold Mine Ore Processing and Production
Fact sheet summarizing main points of National Emissions Standards for Hazardous Air Pollutants for gold ore processing and production facilities, the seventh largest source of mercury air emission in the United States.
Kalies, Stefan; Heinemann, Dag; Schomaker, Markus; Gentemann, Lara; Meyer, Heiko; Ripken, Tammo
2014-01-01
In comparison to standard transfection methods, gold nanoparticle-mediated laser transfection has proven to be a versatile alternative. This is based on its minor influence on cell viability and its high efficiency, especially for the delivery of small molecules like small interfering RNA. However, in order to transfer it to routine usage, a safety aspect is of major concern: The avoidance of nanoparticle uptake by the cells is desired. The immobilization of the gold nanoparticles on cell culture surfaces can address this issue. In this study, we achieved this by silanization of the appropriate surfaces and the binding of gold nanoparticles to them. Comparable perforation efficiencies to the previous approaches of gold nanoparticle-mediated laser transfection with free gold nanoparticles are demonstrated. The uptake of the immobilized particles by the cells is unlikely. Consequently, these investigations offer the possibility of bringing gold nanoparticle-mediated laser transfection closer to routine usage.
Gold-coated copper cone detector as a new standard detector for F2 laser radiation at 157 nm.
Kück, Stefan; Brandt, Friedhelm; Taddeo, Mario
2005-04-20
A new standard detector for high-accuracy measurements of F2 laser radiation at 157 nm is presented. This gold-coated copper cone detector permits the measurement of average powers up to 2 W with an uncertainty of approximately 1%. To the best of our knowledge, this is the first highly accurate standard detector for F2 laser radiation for this power level. It is fully characterized according to Guide to the Expression of Uncertainty in Measurement of the International Organization for Standardization and is connected to the calibration chain for laser radiation established by the German National Metrology Institute.
A theoretical framework for human and veterinary medical ethics education.
Magalhães-Sant'Ana, Manuel
2016-12-01
In their practice, physicians and veterinarians need to resort to an array of ethical competences. As a teaching topic, however, there is no accepted gold standard for human medical ethics, and veterinary medical ethics is not yet well established. This paper provides a reflection on the underlying aims of human and veterinary medical ethics education. Drawing from published literature on ethics education in the health professions a theoretical framework common to the teaching of human and veterinary medical ethics is proposed, based on three concepts: professional rules, moral virtues and ethical skills. The rules approach relies on the transmission of professional and social values by means of regulatory documents and depends intimately on the knowledge that students have of those documents. The virtues approach involves the inculcation of moral values and virtues that will stimulate students to develop desirable behaviours. The main focus of this approach to ethics is to develop students' attitudinal competences. Finally, the skills approach is focused on equipping the students with the necessary moral reasoning abilities to recognise and respect the plurality of ethical views that make part of contemporary society. This framework can inform future curriculum development in human and veterinary medical ethics as well as in other health care professions.
40 CFR 421.256 - Pretreatment standards for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078 Silver 0.377 0.156 Zinc 1.326 0.546 Gold 0.130 (b) Silver chloride reduction spent solution. PSNS for the....024 Silver 0.116 0.048 Zinc 0.408 0.168 Gold 0.040 (c) Electrolytic cells wet air pollution control...
40 CFR 421.256 - Pretreatment standards for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078 Silver 0.377 0.156 Zinc 1.326 0.546 Gold 0.130 (b) Silver chloride reduction spent solution. PSNS for the....024 Silver 0.116 0.048 Zinc 0.408 0.168 Gold 0.040 (c) Electrolytic cells wet air pollution control...
40 CFR 421.256 - Pretreatment standards for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078 Silver 0.377 0.156 Zinc 1.326 0.546 Gold 0.130 (b) Silver chloride reduction spent solution. PSNS for the....024 Silver 0.116 0.048 Zinc 0.408 0.168 Gold 0.040 (c) Electrolytic cells wet air pollution control...
ERIC Educational Resources Information Center
Gaskins, Darlene
2014-01-01
We need to come together as a team and become one system of total quality improvement regarding the education of our nation's children. In order to achieve a gold standard in the education of our nation's children, leadership has to be willing to go against the status quo and build bridges for long-term sustainable change. In order to survive,…
Jani, Kalpesh; Rajan, P S; Sendhilkumar, K; Palanivelu, C
2006-01-01
This review article is a tribute to the genius of Professor Erich Muhe, a man ahead of his times. We trace the development of laparoscopic cholecystectomy and detail the tribulations faced by Muhe. On the occasion of the twentieth anniversary of the first laparoscopic cholecystectomy, we take another look at some of the controversies surrounding this gold standard in the management of gallbladder disease PMID:21170235
Gray, Christine L; Robinson, Whitney R
2014-07-01
In childhood obesity research, the appearance of height loss, or "shrinkage," indicates measurement error. It is unclear whether a common response--excluding "shrinkers" from analysis--reduces bias. Using data from the National Longitudinal Study of Adolescent Health, we sampled 816 female adolescents (≥17 years) who had attained adult height by 1996 and for whom adult height was consistently measured in 2001 and 2008 ("gold-standard" height). We estimated adolescent obesity prevalence and the association of maternal education with adolescent obesity under 3 conditions: excluding shrinkers (for whom gold-standard height was less than recorded height in 1996), retaining shrinkers, and retaining shrinkers but substituting their gold-standard height. When we estimated obesity prevalence, excluding shrinkers decreased precision without improving validity. When we regressed obesity on maternal education, excluding shrinkers produced less valid and less precise estimates. In some circumstances, ignoring shrinkage is a better strategy than excluding shrinkers.
Applying a statistical PTB detection procedure to complement the gold standard.
Noor, Norliza Mohd; Yunus, Ashari; Bakar, S A R Abu; Hussin, Amran; Rijal, Omar Mohd
2011-04-01
This paper investigates a novel statistical discrimination procedure to detect PTB when the gold standard requirement is taken into consideration. Archived data were used to establish two groups of patients which are the control and test group. The control group was used to develop the statistical discrimination procedure using four vectors of wavelet coefficients as feature vectors for the detection of pulmonary tuberculosis (PTB), lung cancer (LC), and normal lung (NL). This discrimination procedure was investigated using the test group where the number of sputum positive and sputum negative cases that were correctly classified as PTB cases were noted. The proposed statistical discrimination method is able to detect PTB patients and LC with high true positive fraction. The method is also able to detect PTB patients that are sputum negative and therefore may be used as a complement to the gold standard. Copyright © 2010 Elsevier Ltd. All rights reserved.
Parent-based diagnosis of ADHD is as accurate as a teacher-based diagnosis of ADHD.
Bied, Adam; Biederman, Joseph; Faraone, Stephen
2017-04-01
To review the literature evaluating the psychometric properties of parent and teacher informants relative to a gold-standard ADHD diagnosis in pediatric populations. We included studies that included both a parent and teacher informant, a gold-standard diagnosis, and diagnostic accuracy metrics. Potential confounds were evaluated. We also assessed the 'OR' and the 'AND' rules for combining informant reports. Eight articles met inclusion criteria. The diagnostic accuracy for predicting gold standard ADHD diagnoses did not differ between parents and teachers. Sample size, sample type, participant drop-out, participant age, participant gender, geographic area of the study, and date of study publication were assessed as potential confounds. Parent and teachers both yielded moderate to good diagnostic accuracy for ADHD diagnoses. Parent reports were statistically indistinguishable from those of teachers. The predictive features of the 'OR' and 'AND' rules are useful in evaluating approaches to better integrating information from these informants.
Koizuka, Mai; Komine, Futoshi; Blatz, Markus B; Fushiki, Ryosuke; Taguchi, Kohei; Matsumura, Hideo
2013-09-01
To evaluate and compare the shear-bond strength of a gingiva-colored indirect composite material to three different implant framework materials (zirconia ceramics, gold alloy, and titanium), and to investigate the effect of surface pretreatment by air-particle abrasion and four priming agents. A gingiva-colored indirect composite (Ceramage) was bonded to three framework materials (n = 80): commercially pure titanium (CP- Ti ), ADA (American Dental Association)-type 4 casting gold alloy (Type IV), and zirconia ceramics (Zirconia) with or without airborne-particle abrasion. Before bonding, the surface of the specimens was treated using no (control) or one of four priming agents: Alloy Primer (ALP), Estenia Opaque Primer (EOP), Metal Link Primer (MLP), and V-Primer (VPR). Shear-bond strength was determined after 24-h wet storage. Data were analyzed using Steel-Dwass for multiple comparisons, and Mann-Whitney U-test (P = 0.05). For both CP- Ti and Zirconia substrates, three groups, ALP, EOP, and MLP, showed significantly higher bond strengths (P < 0.05) than the other groups with or without airborne-particle abrasion. For Type IV substrates, significantly higher bond strengths were obtained in ALP and MLP groups (P < 0.01) compared with the other groups with airborne-particle abrasion. Application of priming agents containing specific phosphoric ester groups significantly enhances the bond strength of a gingiva-colored composite material to commercially pure titanium and zirconia frameworks. Combined use of a thione monomer with a phosphoric monomer enhances the bond strengths to airborne-particle abraded type IV gold alloy. © 2012 John Wiley & Sons A/S.
Gold-rush in a forested El Dorado: deforestation leakages and the need for regional cooperation
NASA Astrophysics Data System (ADS)
Dezécache, Camille; Faure, Emmanuel; Gond, Valéry; Salles, Jean-Michel; Vieilledent, Ghislain; Hérault, Bruno
2017-03-01
Tropical forests of the Guiana Shield are the most affected by gold-mining in South America, experiencing an exponential increase in deforestation since the early 2000’s. Using yearly deforestation data encompassing Guyana, Suriname, French Guiana and the Brazilian State of Amapá, we demonstrated a strong relationship between deforestation due to gold-mining and gold-prices at the regional scale. In order to assess additional drivers of deforestation due to gold-mining, we focused on the national scale and highlighted the heterogeneity of the response to gold-prices under different political contexts. Deforestation due to gold-mining over the Guiana Shield occurs mainly in Guyana and Suriname. On the contrary, past and current repressive policies in Amapá and French Guiana likely contribute to the decorrelation of deforestation and gold prices. In this work, we finally present a case study focusing on French Guiana and Suriname, two neighbouring countries with very different levels of law enforcement against illegal gold-mining. We developed a modelling framework to estimate potential deforestation leakages from French Guiana to Suriname in the border areas. Based on our assumptions, we estimated a decrease in deforestation due to gold-mining of approx. 4300 hectares in French Guiana and an increase of approx. 12 100 hectares in Suriname in response to the active military repression of illegal gold-mining launched in French Guiana. Gold-mining in the Guiana Shield provides challenging questions regarding REDD+ implementation. These questions are discussed at the end of this study and are important to policy makers who need to provide sustainable alternative employment to local populations in order to ensure the effectiveness of environmental policies.
A multilingual gold-standard corpus for biomedical concept recognition: the Mantra GSC.
Kors, Jan A; Clematide, Simon; Akhondi, Saber A; van Mulligen, Erik M; Rebholz-Schuhmann, Dietrich
2015-09-01
To create a multilingual gold-standard corpus for biomedical concept recognition. We selected text units from different parallel corpora (Medline abstract titles, drug labels, biomedical patent claims) in English, French, German, Spanish, and Dutch. Three annotators per language independently annotated the biomedical concepts, based on a subset of the Unified Medical Language System and covering a wide range of semantic groups. To reduce the annotation workload, automatically generated preannotations were provided. Individual annotations were automatically harmonized and then adjudicated, and cross-language consistency checks were carried out to arrive at the final annotations. The number of final annotations was 5530. Inter-annotator agreement scores indicate good agreement (median F-score 0.79), and are similar to those between individual annotators and the gold standard. The automatically generated harmonized annotation set for each language performed equally well as the best annotator for that language. The use of automatic preannotations, harmonized annotations, and parallel corpora helped to keep the manual annotation efforts manageable. The inter-annotator agreement scores provide a reference standard for gauging the performance of automatic annotation techniques. To our knowledge, this is the first gold-standard corpus for biomedical concept recognition in languages other than English. Other distinguishing features are the wide variety of semantic groups that are being covered, and the diversity of text genres that were annotated. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.
Is a mobile emergency severity index (ESI) triage better than the paper ESI?
Savatmongkorngul, Sorravit; Yuksen, Chaiyaporn; Suwattanasilp, Chanakarn; Sawanyawisuth, Kittisak; Sittichanbuncha, Yuwares
2017-12-01
This study aims to evaluate the mobile emergency severity index (ESI) tool in terms of validity compared with the original ESI triage. The original ESI and mobile ESI were used with patients at the Department of Emergency Medicine, Ramathibodi Hospital, Thailand. Eligible patients were evaluated by sixth-year medical students/emergency physicians using either the original or mobile ESI. The ESI results for each patient were compared with the standard ESI. Concordance and kappa statistics were calculated for pairs of the evaluators. There were 486 patients enrolled in the study; 235 patients (48.4%) were assessed using the mobile ESI, and 251 patients (51.6%) were in the original ESI group. The baseline characteristics of patients in both groups were mostly comparable except for the ED visit time. The percentages of concordance and kappa statistics in the original ESI group were lower than in the mobile group in all three comparisons (medical students vs gold standard, emergency physicians vs gold standard, and medical students vs emergency physicians). The highest kappa in the original ESI group is 0.69, comparing emergency physicians vs gold standard, while the lowest kappa in the application group is 0.84 comparing the medical students vs gold standard. Both medical students and emergency physicians are more confident with the mobile ESI application triage. In conclusion, the mobile ESI has better inter-rater reliability, and is more user-friendly than the original paper form.
Formation of noble metal nanocrystals in the presence of biomolecules
NASA Astrophysics Data System (ADS)
Burt, Justin Lockheart
One of the most promising, yet least studied routes for producing biocompatible nanostructures involves synthesis in the presence of biomolecules. I hypothesized that globular proteins could provide a suitable framework to regulate the formation of noble metal nanocrystals. As proof of concept, I designed two novel synthesis protocols utilizing bovine serum albumin (BSA) protein to regulate the formation of gold nanocrystals. In the first case, the standard protocol for polyol reduction was modified by replacing ethylene glycol with glycerin, replacing synthetic polymers with BSA as protecting agent, and decreasing the reaction temperature. In the second case, the Brust-Schiffrin two-phase reduction was modified by replacing alkylthiols with BSA as protecting agent, which facilitated a strictly aqueous phase synthesis. Due to superior product yield and rapid reduction at room temperature, the aqueous protocol became the foundation for subsequent studies. I extended this approach to produce well-dispersed ˜2nm silver, gold, and platinum nanocrystals. Having demonstrated the feasibility of BSA-functionalized nanocrystals, some potential uses were explored. BSA-functionalized silver nanocrystals were employed in a broader study on the interaction of silver nanocrystals with HIV. BSA-functionalized gold nanocrystals were utilized for in vivo dosage of a contrast enhancing agent to bacteria. BSA-functionalized platinum nanocrystals were studied as hydrogenation catalysts. Since many intriguing uses for protein-functionalized nanocrystals involve incorporation into biosystems, I sought to enhance biocompatibility by using ascorbic acid as reducing agent. Initial experiments revealed elongated and branched nanocrystals. Such structures were not observed in previous synthesis protocols with BSA, so I hypothesized ascorbic acid was driving their formation. To test my assertion, I reduced ionic gold in an aqueous solution of ascorbic acid, thereby discovering a new method for producing multiply-branched gold nanocrystals. Two conditions were necessary to achieve multiply-branched structures: rapid kinetics, and strongly acidic pH. By exploiting ascorbic acid complexation with BSA to moderate reaction kinetics, and using sodium hydroxide to provide basic pH, the two conditions for branching were negated, and well-dispersed ˜2.5nm gold nanocrystals were obtained. This protocol represents a novel, environmentally benign approach to producing biocompatible nanocrystals, relying on proteins, ascorbic acid, sodium hydroxide, and water, all at ambient temperature.
Thalamic and extrathalamic mechanisms of consciousness after severe brain injury.
Lutkenhoff, Evan S; Chiang, Jeffrey; Tshibanda, Luaba; Kamau, Evelyn; Kirsch, Murielle; Pickard, John D; Laureys, Steven; Owen, Adrian M; Monti, Martin M
2015-07-01
What mechanisms underlie the loss and recovery of consciousness after severe brain injury? We sought to establish, in the largest cohort of patients with disorders of consciousness (DOC) to date, the link between gold standard clinical measures of awareness and wakefulness, and specific patterns of local brain pathology-thereby possibly providing a mechanistic framework for patient diagnosis, prognosis, and treatment development. Structural T1-weighted magnetic resonance images were collected, in a continuous sample of 143 severely brain-injured patients with DOC (and 96 volunteers), across 2 tertiary expert centers. Brain atrophy in subcortical regions (bilateral thalamus, basal ganglia, hippocampus, basal forebrain, and brainstem) was assessed across (1) healthy volunteers and patients, (2) clinical entities (eg, vegetative state, minimally conscious state), (3) clinical measures of consciousness (Coma Recovery Scale-Revised), and (4) injury etiology. Compared to volunteers, patients exhibited significant atrophy across all structures (p < 0.05, corrected). Strikingly, we found almost no significant differences across clinical entities. Nonetheless, the clinical measures of awareness and wakefulness upon which differential diagnosis rely were systematically associated with tissue atrophy within thalamic and basal ganglia nuclei, respectively; the basal forebrain was atrophied in proportion to patients' response to sensory stimulation. In addition, nontraumatic injuries exhibited more extensive thalamic atrophy. These findings provide, for the first time, a grounding in pathology for gold standard behavior-based clinical measures of consciousness, and reframe our current models of DOC by stressing the different links tying thalamic mechanisms to willful behavior and extrathalamic mechanisms to behavioral (and electrocortical) arousal. © 2015 American Neurological Association.
40 CFR 421.254 - Standards of performance for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... average mg/troy ounce of gold refined electrolytically Lead 5.544 2.574 Mercury 2.970 1.188 Silver 5.742 2... property Maximum for any 1 day Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0... reduced in solution Lead 0.112 0.052 Mercury 0.060 0.024 Silver 0.116 0.048 Zinc 0.408 0.168 Gold 0.040...
40 CFR 421.261 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... apply to this subpart. (b) The term precious metals shall mean gold, platinum, palladium, rhodium, iridium, osmium, and ruthenium. (c) The term Combined Metals, shall mean the total of gold, platinum and... AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Secondary Precious Metals...
Adequate Patient Characterization in COPD: Reasons to Go Beyond GOLD Classification
Verhage, Tewe L; Heijdra, Yvonne F; Molema, Johan; Daudey, Leonie; Dekhuijzen, P.N Richard; Vercoulen, Jan H
2009-01-01
The Global Initiative for Chronic Obstructive Lung Disease (GOLD) serves as a guide to treat and manage different severity classes of patients with COPD. It was suggested that the five categories of FEV1 % predicted (GOLD 0–4), can be applied for selecting different therapeutic approaches. However, validation of these selective properties is very poor. To determine the relevance of the GOLD staging system for estimating the severity of clinical problems, GOLD 2 (n=70) and GOLD 3 (n=65) patients were drawn from a prospective cohort of patients with COPD and evaluated crosssectionally by a newly developed Nijmegen Integral Assessment Framework (NIAF). The NIAF is a detailed assessment of a wide range of aspects of health status (HS). Significant, though small, differences were found in Static Lung Volumes, Exercise Capacity, Subjective Pulmonary Complaints, Subjective Impairment, and Health-Related QoL, besides Airflow of course. Moreover, overlap between scores of these five HS sub-domains was substantial, indicating small clinical relevance for discernment. No significant differences were found in nine other aspects of HS. It is concluded that GOLD stages do not discriminate in any aspect of HS other than airflow obstruction, and therefore do not help the clinician in deciding which treatment modalities are appropriate. PMID:19452033
ERIC Educational Resources Information Center
Gillard, J. W.
2018-01-01
In this paper, we look at the results from the recent Teaching Excellence Framework (2017), which were made publicly available in June 2017. We offer some initial analysis and commentary, look at the primary reasons for providers being awarded Bronze, Silver and Gold, and look at some providers close to the borderline for their award. We…
NASA Astrophysics Data System (ADS)
Lahiri, Arnab; Mondal, Pranab K.
2018-04-01
Spatiotemporal thermal response and characteristics of net entropy production rate of a gold nanosphere (radius: 50-200 nm), subjected to a short-pulse, femtosecond laser is reported. In order to correctly illustrate the temperature history of laser-metal interaction(s) at picoseconds transient with a comprehensive single temperature definition in macroscale and to further understand how the thermophysical response of the single-phase lag (SPL) and dual-phase lag (DPL) frameworks (with various lag-ratios') differs, governing energy equations derived from these benchmark non-Fourier frameworks are numerically solved and thermodynamic assessment under both the classical irreversible thermodynamics (CIT) as well as extended irreversible thermodynamics (EIT) frameworks is subsequently carried out. Under the frameworks of SPL and DPL with small lag ratio, thermophysical anomalies such as temperature overshooting characterized by adverse temperature gradient is observed to violate the local thermodynamic equilibrium (LTE) hypothesis. The EIT framework, however, justifies the compatibility of overshooting of temperature with the second law of thermodynamics under a nonequilibrium paradigm. The DPL framework with higher lag ratio was however observed to remain free from temperature overshooting and finds suitable consistency with LTE hypothesis. In order to solve the dimensional non-Fourier governing energy equation with volumetric laser-irradiation source term(s), the lattice Boltzmann method (LBM) is extended and a three-time level, fully implicit, second order accurate finite difference method (FDM) is illustrated. For all situations under observation, the LBM scheme is featured to be computationally superior to remaining FDM schemes. With detailed prediction of maximum temperature rise and the corresponding peaking time by all the numerical schemes, effects of the change of radius of the gold nanosphere, the magnitude of fluence of laser, and laser irradiation with multiple pulses on thermal energy transport and lagging behavior (if any) are further elucidated at different radial locations of the gold nanosphere. Last, efforts are further made to address the thermophysical characteristics when effective thermal conductivity (with temporal and size effects) is considered instead of the usual bulk thermal conductivity.
Ortorp, Anders; Jemt, Torsten
2008-09-01
Comparative long-term knowledge of different framework materials in the partially edentulous implant patient is not available. To report and compare 10-year data on free-standing implant-supported partial prostheses with laser-welded titanium (test) and conventional gold alloy (control) frameworks. Altogether, 52 partially edentulous patients were consecutively provided with laser-welded prostheses (n = 60) in the partially edentulous lower jaw (test group). A control group of 52 randomly selected patients with gold alloy castings (n = 60) was used for comparison. Clinical and radiographic 10-year data were retrospectively collected and evaluated for both groups. The overall 10-year implant cumulative survival rate (CSR) was 93.0% (loaded implants, 96.4%), with a 10-year implant CSR of 91.5 and 94.7% for test and control implants, respectively (p > .05). Out of a total of 22 lost implants, 17 implants (77.3%) were shorter than 10 mm. The overall 10-year prosthesis CSR was 93.7%, with a corresponding 10-year CSR of 88.4 and 100% for test and control groups, respectively (p < .05). Average 10-year bone loss was 0.46 mm (SD 0.47) and 0.69 mm (SD 0.53) for the test and control groups (p < .001), respectively. Only 1% of the implants had >3 mm accumulated bone loss after 10 years. Altogether, 10 of the prostheses in both groups had implant component mechanical problems (8.3%). None of the frameworks or implants fractured, but more fractures of porcelain veneers were observed in the test group (p < .05). The protocol of implant treatment in the partially edentulous jaw functioned well during 10 years, although prosthodontic maintenance was required. However, laser-welded titanium frameworks presented more problems as compared with gold alloy frameworks. More loaded implants were lost (p < .05), and higher incidence of porcelain chipping was noted in the test group (p < .05). However, bone loss was on an average lower for the test group during the 10 years of follow-up (p < .001).
García, Patricia; Balcells, M Elvira; Castillo, Claudia; Miranda, Carolina; Geoffroy, Enrique; Román, Juan C; Wozniak, Aniela
2017-08-01
Extra-pulmonary tuberculosis (TB) represents the 26.2% of total TB cases in Chile. Culture is the gold standard method, but the process is extremely slow. Xpert®MTB/RIF technique detects Mycobacterium tuberculosis complex (MTBc) through real time PCR in less than 3 h. However, it has been validated only for respiratory specimens. We aimed to determine the performance of Xpert®MTB/RIF test in detecting MTBc in extra-respiratory specimens compared with a combined gold standard consisting in a positive (liquid and solid) mycobacterial culture and/or a positive validated molecular method (q-RPC, Cobas®TaqMan®-MTB). Fifty extra-respiratory specimens were analyzed, from which 25 were positive and 25 negative for MTBc based on the combined gold standard. The 25 positive specimens had a positive result by Xpert®MTB/RIF; from the 25 negative specimens, 24 had a negative result and one had a positive result. We obtained an overall concordance of 98% between Xpert®MTB/RIF and the combined gold standard. Xpert®MTB/RIF test was able to detect 12 smear-negative specimens and 3 culture-negative specimens, all of them corresponding to extra-pulmonary TB cases. Xpert®MTB/RIF showed similar sensitivity to q-RPC in detecting MTBc in extra-respiratory specimens. This procedure allowed a substantial reduction in the time of diagnosis.
On-line hemodiafiltration. Gold standard or top therapy?
Passlick-Deetjen, Jutta; Pohlmeier, Robert
2002-01-01
In summary, on-line HDF is an extracorporeal blood purification therapy with increased convective removal of uremic toxins as compared to the most frequently used low- or high-flux HD therapy. The clinical advantages of on-line HDF have shown to be dose dependent, which makes on-line HDF superior to other therapies with less convective solute removal. Among the therapies with high convective solute removal, i.e. on-line HDF, on-line HF and double high-flux dialysis, it is difficult to finally decide on the best therapy, as direct comparisons of these therapies are not performed. Theoretical considerations like the relative to on-line HDF lower achievable Kt/Vurea with on-line HF, allow to state that on-line HDF is the top therapy now available for patients with ESRD. A gold standard may be defined as something with which everything else is compared if one tries to establish it in the respective field. In order to declare on-line HDF as the gold standard in renal replacement therapy, we need more direct comparisons of on-line HDF with other therapies, including mortality as an outcome parameter. However, based on our current knowledge, it does not seem to be too speculative that high-quality clinical studies will establish on-line HDF in the next years as the new gold standard in renal replacement therapy.
Daily sodium and potassium excretion can be estimated by scheduled spot urine collections.
Doenyas-Barak, Keren; Beberashvili, Ilia; Bar-Chaim, Adina; Averbukh, Zhan; Vogel, Ofir; Efrati, Shai
2015-01-01
The evaluation of sodium and potassium intake is part of the optimal management of hypertension, metabolic syndrome, renal stones, and other conditions. To date, no convenient method for its evaluation exists, as the gold standard method of 24-hour urine collection is cumbersome and often incorrectly performed, and methods that use spot or shorter collections are not accurate enough to replace the gold standard. The aim of this study was to evaluate the correlation and agreement between a new method that uses multiple-scheduled spot urine collection and the gold standard method of 24-hour urine collection. The urine sodium or potassium to creatinine ratios were determined for four scheduled spot urine samples. The mean ratios of the four spot samples and the ratios of each of the single spot samples were corrected for estimated creatinine excretion and compared to the gold standard. A significant linear correlation was demonstrated between the 24-hour urinary solute excretions and estimated excretion evaluated by any of the scheduled spot urine samples. The correlation of the mean of the four spots was better than for any of the single spots. Bland-Altman plots showed that the differences between these measurements were within the limits of agreement. Four scheduled spot urine samples can be used as a convenient method for estimation of 24-hour sodium or potassium excretion. © 2015 S. Karger AG, Basel.
Higgins, H. M.; Huxley, J. N.; Wapenaar, W.; Green, M. J.
2013-01-01
Characteristics of 94 veterinary surgeons associated with delivering preventive herd-level strategies to control mastitis, lameness and Johne's disease were investigated using two multinomial models. The response variables were ‘Gold Standard Monitoring’ (including on-going data analysis, risk assessments and laboratory testing), and a lower level of involvement called ‘Regular Control Advice’. Although the sample was biased towards those who spend the majority of their time with dairy cows, 69 per cent currently had no involvement in Gold Standard Monitoring for lameness, 60 per cent no involvement with Johne's, and 52 per cent no involvement with mastitis. The final model predicted that an assistant without a postgraduate cattle qualification, who had spent no time on dairy cattle continuous professional development (CPD) in the last year, had an 88 per cent chance of having no involvement with Gold Standard Monitoring for any disease, versus <5 per cent chance for a CPD ‘enriched’ partner with a postgraduate cattle qualification; there was <1 per cent chance this assistant would be involved with Gold Standard Monitoring of all three diseases on one or more farms, versus a 58 per cent chance for this partner. CPD and employment status were also associated with markedly different probabilities for delivering Regular Control Advice. Increased postgraduate education may further veterinary involvement of this nature. PMID:23887976
Hardick, Justin; Dugas, Andrea; Goheen, Joshua; Rothman, Richard; Gaydos, Charlotte
2015-03-01
RT-PCR/ESI-MS has previously demonstrated the capability to detect and identify respiratory viral pathogens in nasopharyngeal swabs. This study expands on previous research by performing a prospective evaluation of RT-PCR/ESI-MS to detect and identify Influenza A and B viruses compared to Prodesse ProFlu Plus and combined ProFlu Plus and Cepheid Xpert Flu. ProFlu Plus was also used as a gold standard for comparison for respiratory syncytial virus detection. Using ProFlu Plus as a gold standard, RT-PCR/ESI-MS had sensitivity and specificity of 82.1% (23/28) and 100% (258/258), respectively, for Influenza A, 100% (16/16) and 99.6% (269/270), respectively for Influenza B, and 88.6% (39/44) and 99.6% (241/242) for any Influenza virus. Using matching results from ProFlu Plus and Xpert Flu as a gold standard, RT-PCR/ESI-MS had 85.2% (23/27) and 100% (259/259) sensitivity and specificity respectively for Influenza A, 100% (14/14) and 99.6% (270/272), respectively for Influenza B virus. Overall, RT-PCR/ESI-MS was not as sensitive as the combined gold standard of ProFlu Plus and Xpert Flu, although it has the capability of detecting other respiratory viruses. Copyright © 2015 Elsevier B.V. All rights reserved.
Chen, J.R.; Chao, E.C.T.; Minkin, J.A.; Back, J.M.; Bagby, W.C.; Rivers, M.L.; Sutton, S.R.; Gordon, B.M.; Hanson, A.L.; Jones, K.W.
1987-01-01
The occurrence of the so-called invisible gold in two unoxidized Carlin-type gold samples from Nevada has been determined using synchrotron X-ray fluorescence (SXRF) analysis at the National Synchrotron Light Source, Brookhaven National Laboratory. A bedded sample from the East ore zone of the Carlin deposit and a breccia sample from Horse Canyon were analyzed. Preliminary results show that gold is found only in the Horse Canyon breccia sample. Experimental details including other X-ray line and diffraction peak interferences, standards used, and minimum detection limits (MDLs) are discussed. Gold, with a MDL range of 0.8 to 3 ppm, was not detected in euhedral pyrite crystals except in the interior porous portion of one grain. Gold was detected in some parts of the matrix. The phase which contains gold has not yet been identified. The highest content of gold so far analyzed is about 40 ppm. There are interesting implications of these new findings. ?? 1987.
MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghose, Soumya, E-mail: soumya.ghose@case.edu; Mitra, Jhimli; Rivest-Hénault, David
Purpose: The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Methods: Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contoursmore » were selected in a spectral clustering manifold learning framework. This aids in clustering “similar” gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. Results: A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). Conclusions: An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold seeds are either correctly detected or a warning is raised for further manual intervention.« less
MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection.
Ghose, Soumya; Mitra, Jhimli; Rivest-Hénault, David; Fazlollahi, Amir; Stanwell, Peter; Pichler, Peter; Sun, Jidi; Fripp, Jurgen; Greer, Peter B; Dowling, Jason A
2016-05-01
The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contours were selected in a spectral clustering manifold learning framework. This aids in clustering "similar" gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold seeds are either correctly detected or a warning is raised for further manual intervention.
Can context justify an ethical double standard for clinical research in developing countries?
Landes, Megan
2005-01-01
Background The design of clinical research deserves special caution so as to safeguard the rights of participating individuals. While the international community has agreed on ethical standards for the design of research, these frameworks still remain open to interpretation, revision and debate. Recently a breach in the consensus of how to apply these ethical standards to research in developing countries has occurred, notably beginning with the 1994 placebo-controlled trials to reduce maternal to child transmission of HIV-1 in Africa, Asia and the Caribbean. The design of these trials sparked intense debate with the inclusion of a placebo-control group despite the existence of a 'gold standard' and trial supporters grounded their justifications of the trial design on the context of scarcity in resource-poor settings. Discussion These 'contextual' apologetics are arguably an ethical loophole inherent in current bioethical methodology. However, this convenient appropriation of 'contextual' analysis simply fails to acknowledge the underpinnings of feminist ethical analysis upon which it must stand. A more rigorous analysis of the political, social, and economic structures pertaining to the global context of developing countries reveals that the bioethical principles of beneficence and justice fail to be met in this trial design. Conclusion Within this broader, and theoretically necessary, understanding of context, it becomes impossible to justify an ethical double standard for research in developing countries. PMID:16045801
Yang, Nan; You, Ting-Ting; Gao, Yu-Kun; Zhang, Chen-Meng; Yin, Penggang
2018-06-08
Surface enhanced Raman scattering (SERS) has been widely used in detection of food safety due to the nondestructive examination property. Here, we reported a flexible SERS film based on polymer immobilized gold nanorods polymer metafilm. Polystyrene-polyisoprene-polystyrene (SIS), a transparent and flexible along with excellent elasticity polymer was chosen as main support of gold nanorods. A simple phase transfer progress was adopted to mix the gold nanorods with polymer which can further used in most water-insoluble polymers. The SERS film performed satisfactorily while tested in a series of standard Raman probes like crystal violet (CV) and malachite green (MG). Moreover, the excellent reproducibility and elastic properties make the film promising substrates in practical detection. Hence, the MG detection on fish surface and trace thiram detection on orange pericarp were inspected with the detection result of 1 × 10-10 M and 1 × 10-6 M which below the demand of National standard of China, exactly matching the realistic application requirements.
Wu, Danny T Y; Smart, Nikolas; Ciemins, Elizabeth L; Lanham, Holly J; Lindberg, Curt; Zheng, Kai
2017-01-01
To develop a workflow-supported clinical documentation system, it is a critical first step to understand clinical workflow. While Time and Motion studies has been regarded as the gold standard of workflow analysis, this method can be resource consuming and its data may be biased due to the cognitive limitation of human observers. In this study, we aimed to evaluate the feasibility and validity of using EHR audit trail logs to analyze clinical workflow. Specifically, we compared three known workflow changes from our previous study with the corresponding EHR audit trail logs of the study participants. The results showed that EHR audit trail logs can be a valid source for clinical workflow analysis, and can provide an objective view of clinicians' behaviors, multi-dimensional comparisons, and a highly extensible analysis framework.
Clusters of Monoisotopic Elements for Calibration in (TOF) Mass Spectrometry
NASA Astrophysics Data System (ADS)
Kolářová, Lenka; Prokeš, Lubomír; Kučera, Lukáš; Hampl, Aleš; Peňa-Méndez, Eladia; Vaňhara, Petr; Havel, Josef
2017-03-01
Precise calibration in TOF MS requires suitable and reliable standards, which are not always available for high masses. We evaluated inorganic clusters of the monoisotopic elements gold and phosphorus (Au n +/Au n - and P n +/P n -) as an alternative to peptides or proteins for the external and internal calibration of mass spectra in various experimental and instrumental scenarios. Monoisotopic gold or phosphorus clusters can be easily generated in situ from suitable precursors by laser desorption/ionization (LDI) or matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Their use offers numerous advantages, including simplicity of preparation, biological inertness, and exact mass determination even at lower mass resolution. We used citrate-stabilized gold nanoparticles to generate gold calibration clusters, and red phosphorus powder to generate phosphorus clusters. Both elements can be added to samples to perform internal calibration up to mass-to-charge ( m/z) 10-15,000 without significantly interfering with the analyte. We demonstrated the use of the gold and phosphorous clusters in the MS analysis of complex biological samples, including microbial standards and total extracts of mouse embryonic fibroblasts. We believe that clusters of monoisotopic elements could be used as generally applicable calibrants for complex biological samples.
Terminalia chebula mediated green and rapid synthesis of gold nanoparticles
NASA Astrophysics Data System (ADS)
Mohan Kumar, Kesarla; Mandal, Badal Kumar; Sinha, Madhulika; Krishnakumar, Varadhan
2012-02-01
Biologically inspired experimental process in synthesising nanoparticles is of great interest in present scenario. Biosynthesis of nanoparticles is considered to be one of the best green techniques in synthesising metal nanoparticles. Here, an in situ green biogenic synthesis of gold nanoparticles using aqueous extracts of Terminalia chebula as reducing and stabilizing agent is reported. Gold nanoparticles were confirmed by surface plasmon resonance in the range of 535 nm using UV-visible spectrometry. TEM analysis revealed that the morphology of the particles thus formed contains anisotropic gold nanoparticles with size ranging from 6 to 60 nm. Hydrolysable tannins present in the extract of T. chebula are responsible for reductions and stabilization of gold nanoparticles. Antimicrobial activity of gold nanoparticles showed better activity towards gram positive S. aureus compared to gram negative E. coli using standard well diffusion method.
Amuse, M A; Kuchekar, S R; Mote, N A; Chavan, M B
1985-10-01
Tervalent gold was determined spectrophotometrically as its anionic 1:4 gold-thiol complex extracted into chloroform from aqueous acidic medium (1.5M sulphuric acid) in the presence of tri-iso-octylamine. The complex exhibits maximum absorption at 480 nm (molar absorptivity 4.60 x 10(3) l.mole(-1).cm(-1)) and Beer's law is obeyed in the concentration range 5-50 microg of gold(III) per ml. The relative standard deviation and relative error, calculated from ten determinations of solutions containing 15 microg of gold(III) per ml were 1.0% and 0.8%. The method is simple, selective and reproducible. It permits separation of gold(III) from associated elements and its determination in synthetic mixtures.
Day, Sara W.; McKeon, Leslie M.; Garcia, Jose; Wilimas, Judith A.; Carty, Rita M.; de Alarcon, Pedro; Antillon, Federico; Howard, Scott C.
2017-01-01
Background Inadequate nursing care is a major impediment to development of effective programs for treatment of childhood cancer in low-income countries. When the International Outreach Program at St. Jude Children’s Research Hospital established partner sites in low-income countries, few nurses had pediatric oncology skills or experience. A comprehensive nursing program was developed to promote the provision of quality nursing care, and in this manuscript we describe the program’s impact on 20 selected Joint Commission International (JCI) quality standards at the National Pediatric Oncology Unit in Guatemala. We utilized JCI standards to focus the nursing evaluation and implementation of improvements. These standards were developed to assess public hospitals in low-income countries and are recognized as the gold standard of international quality evaluation. Methods We compared the number of JCI standards met before and after the nursing program was implemented using direct observation of nursing care; review of medical records, policies, procedures, and job descriptions; and interviews with staff. Results In 2006, only 1 of the 20 standards was met fully, 2 partially, and 17 not met. In 2009, 16 were met fully, 1 partially, and 3 not met. Several factors contributed to the improvement. The pre-program quality evaluation provided objective and credible findings and an organizational framework for implementing change. The medical, administrative, and nursing staff worked together to improve nursing standards. Conclusion A systematic approach and involvement of all hospital disciplines led to significant improvement in nursing care that was reflected by fully meeting 16 of 20 standards. PMID:23015363
Patterning of oxide-hardened gold black by photolithography and metal lift-off
NASA Astrophysics Data System (ADS)
Panjwani, Deep; Yesiltas, Mehmet; Nath, Janardan; Maukonen, D. E.; Rezadad, Imen; Smith, Evan M.; Peale, R. E.; Hirschmugl, Carol; Sedlmair, Julia; Wehlitz, Ralf; Unger, Miriam; Boreman, Glenn
2014-01-01
A method to pattern infrared-absorbing gold black by conventional photolithography and lift-off is described. A photo-resist pattern is developed on a substrate by standard photolithography. Gold black is deposited over the whole by thermal evaporation in an inert gas at ˜1 Torr. SiO2 is then deposited as a protection layer by electron beam evaporation. Lift-off proceeds by dissolving the photoresist in acetone. The resulting sub-millimeter size gold black patterns that remain on the substrate retain high infrared absorption out to ˜5 μm wavelength and exhibit good mechanical stability. This technique allows selective application of gold black coatings to the pixels of thermal infrared imaging array detectors.
ASSESSING AND COMBINING RELIABILITY OF PROTEIN INTERACTION SOURCES
LEACH, SONIA; GABOW, AARON; HUNTER, LAWRENCE; GOLDBERG, DEBRA S.
2008-01-01
Integrating diverse sources of interaction information to create protein networks requires strategies sensitive to differences in accuracy and coverage of each source. Previous integration approaches calculate reliabilities of protein interaction information sources based on congruity to a designated ‘gold standard.’ In this paper, we provide a comparison of the two most popular existing approaches and propose a novel alternative for assessing reliabilities which does not require a gold standard. We identify a new method for combining the resultant reliabilities and compare it against an existing method. Further, we propose an extrinsic approach to evaluation of reliability estimates, considering their influence on the downstream tasks of inferring protein function and learning regulatory networks from expression data. Results using this evaluation method show 1) our method for reliability estimation is an attractive alternative to those requiring a gold standard and 2) the new method for combining reliabilities is less sensitive to noise in reliability assignments than the similar existing technique. PMID:17990508
Jacob, Joshua; Desai, Ankit; Trompeter, Alex
2017-01-01
Currently, approximately half of all hip fractures are extracapsular, with an incidence as high as 50 in 100,000 in some countries. The common classification systems fail to explain the logistics of fracture classification and whether they all behave in the same manner. The Muller AO classification system is a useful platform to delineate stable and unstable fractures. The Dynamic hip screw (DHS) however, has remained the 'gold standard' implant of choice for application in all extracapsular fractures. The DHS relies on the integrity and strength of the lateral femoral wall as well as the postero-medial fragment. An analysis of several studies indicates significant improvements in design and techniques to ensure a better outcome with intramedullary nails. This article reviews the historical trends that helped to evolve the DHS implant as well as discussing if the surgeon should remain content with this implant. We suggest that the gold standard surgical management of extracapsular fractures can, and should, evolve.
Evaluation of diagnostic accuracy in detecting ordered symptom statuses without a gold standard
Wang, Zheyu; Zhou, Xiao-Hua; Wang, Miqu
2011-01-01
Our research is motivated by 2 methodological problems in assessing diagnostic accuracy of traditional Chinese medicine (TCM) doctors in detecting a particular symptom whose true status has an ordinal scale and is unknown—imperfect gold standard bias and ordinal scale symptom status. In this paper, we proposed a nonparametric maximum likelihood method for estimating and comparing the accuracy of different doctors in detecting a particular symptom without a gold standard when the true symptom status had an ordered multiple class. In addition, we extended the concept of the area under the receiver operating characteristic curve to a hyper-dimensional overall accuracy for diagnostic accuracy and alternative graphs for displaying a visual result. The simulation studies showed that the proposed method had good performance in terms of bias and mean squared error. Finally, we applied our method to our motivating example on assessing the diagnostic abilities of 5 TCM doctors in detecting symptoms related to Chills disease. PMID:21209155
Can Systematic Reviews Inform GMO Risk Assessment and Risk Management?
Kohl, Christian; Frampton, Geoff; Sweet, Jeremy; Spök, Armin; Haddaway, Neal Robert; Wilhelm, Ralf; Unger, Stefan; Schiemann, Joachim
2015-01-01
Systematic reviews represent powerful tools to identify, collect, synthesize, and evaluate primary research data on specific research questions in a highly standardized and reproducible manner. They enable the defensible synthesis of outcomes by increasing precision and minimizing bias whilst ensuring transparency of the methods used. This makes them especially valuable to inform evidence-based risk analysis and decision making in various topics and research disciplines. Although seen as a "gold standard" for synthesizing primary research data, systematic reviews are not without limitations as they are often cost, labor and time intensive and the utility of synthesis outcomes depends upon the availability of sufficient and robust primary research data. In this paper, we (1) consider the added value systematic reviews could provide when synthesizing primary research data on genetically modified organisms (GMO) and (2) critically assess the adequacy and feasibility of systematic review for collating and analyzing data on potential impacts of GMOs in order to better inform specific steps within GMO risk assessment and risk management. The regulatory framework of the EU is used as an example, although the issues we discuss are likely to be more widely applicable.
Volden, Sondre; Kjøniksen, Anna-Lena; Zhu, Kaizheng; Genzer, Jan; Nyström, Bo; Glomm, Wilhelm R
2010-02-23
We demonstrate that the optical properties of gold nanoparticles can be used to detect and follow stimuli-induced changes in adsorbed macromolecules. Specifically, we investigate thermal response of anionic diblock and uncharged triblock copolymers based on poly(N-isopropylacrylamide) (PNIPAAM) blocks adsorbed onto gold nanoparticles and planar gold surfaces in a temperature range between 25 and 60 degrees C. By employing a palette of analytical probes, including UV-visible spectroscopy, dynamic light scattering, fluorescence, and quartz crystal microbalance with dissipation monitoring, we establish that while the anionic copolymer forms monolayers at both low and high temperature, the neutral copolymer adsorbs as a monolayer at low temperatures and forms multilayers above the cloud point (T(C)). Raising the temperature above T(C) severely affects the optical properties of the gold particle/polymer composites, expelling associated water and altering the immediate surroundings of the gold nanoparticles. This effect, stronger for the uncharged polymer, is related to the amount of polymer adsorbed on the surface, where a denser shell influences the surface plasmon band to a greater degree. This is corroborated with light scattering experiments, which reveal that flocculation of the neutral polymer-coated particles occurs at high temperatures. The flocculation behavior of the neutral copolymer on planar gold surfaces results in multilayer formation. The observed effects are discussed within the framework of the Mie-Drude theory.
Sousa, Thiago Oliveira; Haiter-Neto, Francisco; Nascimento, Eduarda Helena Leandro; Peroni, Leonardo Vieira; Freitas, Deborah Queiroz; Hassan, Bassam
2017-07-01
The aim of this study was to assess the diagnostic accuracy of periapical radiography (PR) and cone-beam computed tomographic (CBCT) imaging in the detection of the root canal configuration (RCC) of human premolars. PR and CBCT imaging of 114 extracted human premolars were evaluated by 2 oral radiologists. RCC was recorded according to Vertucci's classification. Micro-computed tomographic imaging served as the gold standard to determine RCC. Accuracy, sensitivity, specificity, and predictive values were calculated. The Friedman test compared both PR and CBCT imaging with the gold standard. CBCT imaging showed higher values for all diagnostic tests compared with PR. Accuracy was 0.55 and 0.89 for PR and CBCT imaging, respectively. There was no difference between CBCT imaging and the gold standard, whereas PR differed from both CBCT and micro-computed tomographic imaging (P < .0001). CBCT imaging was more accurate than PR for evaluating different types of RCC individually. Canal configuration types III, VII, and "other" were poorly identified on CBCT imaging with a detection accuracy of 50%, 0%, and 43%, respectively. With PR, all canal configurations except type I were poorly visible. PR presented low performance in the detection of RCC in premolars, whereas CBCT imaging showed no difference compared with the gold standard. Canals with complex configurations were less identifiable using both imaging methods, especially PR. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Young, Helen T M; Carr, Norman J; Green, Bryan; Tilley, Charles; Bhargava, Vidhi; Pearce, Neil
2013-08-01
To compare the accuracy of eyeball estimates of the Ki-67 proliferation index (PI) with formal counting of 2000 cells as recommend by the Royal College of Pathologists. Sections from gastroenteropancreatic neuroendocrine tumours were immunostained for Ki-67. PI was calculated using three methods: (1) a manual tally count of 2000 cells from the area of highest nuclear labelling using a microscope eyepiece graticule; (2) eyeball estimates made by four pathologists within the same area of highest nuclear labelling; and (3) image analysis of microscope photographs taken from this area using the ImageJ 'cell counter' tool. ImageJ analysis was considered the gold standard for comparison. Levels of agreement between methods were evaluated using Bland-Altman plots. Agreement between the manual tally and ImageJ assessments was very high at low PIs. Agreement between eyeball assessments and ImageJ analysis varied between pathologists. Where data for low PIs alone were analysed, there was a moderate level of agreement between pathologists' estimates and the gold standard, but when all data were included, agreement was poor. Manual tally counts of 2000 cells exhibited similar levels of accuracy to the gold standard, especially at low PIs. Eyeball estimates were significantly less accurate than the gold standard. This suggests that tumour grades may be misclassified by eyeballing and that formal tally counting of positive cells produces more reliable results. Further studies are needed to identify accurate clinically appropriate ways of calculating.
A studentized permutation test for three-arm trials in the 'gold standard' design.
Mütze, Tobias; Konietschke, Frank; Munk, Axel; Friede, Tim
2017-03-15
The 'gold standard' design for three-arm trials refers to trials with an active control and a placebo control in addition to the experimental treatment group. This trial design is recommended when being ethically justifiable and it allows the simultaneous comparison of experimental treatment, active control, and placebo. Parametric testing methods have been studied plentifully over the past years. However, these methods often tend to be liberal or conservative when distributional assumptions are not met particularly with small sample sizes. In this article, we introduce a studentized permutation test for testing non-inferiority and superiority of the experimental treatment compared with the active control in three-arm trials in the 'gold standard' design. The performance of the studentized permutation test for finite sample sizes is assessed in a Monte Carlo simulation study under various parameter constellations. Emphasis is put on whether the studentized permutation test meets the target significance level. For comparison purposes, commonly used Wald-type tests, which do not make any distributional assumptions, are included in the simulation study. The simulation study shows that the presented studentized permutation test for assessing non-inferiority in three-arm trials in the 'gold standard' design outperforms its competitors, for instance the test based on a quasi-Poisson model, for count data. The methods discussed in this paper are implemented in the R package ThreeArmedTrials which is available on the comprehensive R archive network (CRAN). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Vasconcelos, Taruska Ventorini; Neves, Frederico Sampaio; Moraes, Lívia Almeida Bueno; Freitas, Deborah Queiroz
2015-01-01
This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.
Electroanalytical sensing of chromium(III) and (VI) utilising gold screen printed macro electrodes.
Metters, Jonathan P; Kadara, Rashid O; Banks, Craig E
2012-02-21
We report the fabrication of gold screen printed macro electrodes which are electrochemically characterised and contrasted to polycrystalline gold macroelectrodes with their potential analytical application towards the sensing of chromium(III) and (VI) critically explored. It is found that while these gold screen printed macro electrodes have electrode kinetics typically one order of magnitude lower than polycrystalline gold macroelectrodes as is measured via a standard redox probe, in terms of analytical sensing, these gold screen printed macro electrodes mimic polycrystalline gold in terms of their analytical performance towards the sensing of chromium(III) and (VI), whilst boasting additional advantages over the macro electrode due to their disposable one-shot nature and the ease of mass production. An additional advantage of these gold screen printed macro electrodes compared to polycrystalline gold is the alleviation of the requirement to potential cycle the latter to form the required gold oxide which aids in the simplification of the analytical protocol. We demonstrate that gold screen printed macro electrodes allow the low micro-molar sensing of chromium(VI) in aqueous solutions over the range 10 to 1600 μM with a limit of detection (3σ) of 4.4 μM. The feasibility of the analytical protocol is also tested through chromium(VI) detection in environmental samples.
NASA Astrophysics Data System (ADS)
Lehmann, Thomas M.
2002-05-01
Reliable evaluation of medical image processing is of major importance for routine applications. Nonetheless, evaluation is often omitted or methodically defective when novel approaches or algorithms are introduced. Adopted from medical diagnosis, we define the following criteria to classify reference standards: 1. Reliance, if the generation or capturing of test images for evaluation follows an exactly determined and reproducible protocol. 2. Equivalence, if the image material or relationships considered within an algorithmic reference standard equal real-life data with respect to structure, noise, or other parameters of importance. 3. Independence, if any reference standard relies on a different procedure than that to be evaluated, or on other images or image modalities than that used routinely. This criterion bans the simultaneous use of one image for both, training and test phase. 4. Relevance, if the algorithm to be evaluated is self-reproducible. If random parameters or optimization strategies are applied, reliability of the algorithm must be shown before the reference standard is applied for evaluation. 5. Significance, if the number of reference standard images that are used for evaluation is sufficient large to enable statistically founded analysis. We demand that a true gold standard must satisfy the Criteria 1 to 3. Any standard only satisfying two criteria, i.e., Criterion 1 and Criterion 2 or Criterion 1 and Criterion 3, is referred to as silver standard. Other standards are termed to be from plastic. Before exhaustive evaluation based on gold or silver standards is performed, its relevance must be shown (Criterion 4) and sufficient tests must be carried out to found statistical analysis (Criterion 5). In this paper, examples are given for each class of reference standards.
NASA Astrophysics Data System (ADS)
Liu, Weiyu; Wang, Chunhui; Ding, Haitao; Shao, Jinyou; Ding, Yucheng
2016-05-01
In this work, we focus on frequency-dependence of pearl chain formations (PCF) of gold nanoparticles driven by AC dielectrophoresis (DEP), especially in a low field-frequency range, where induced double-layer charging effect at ideally polarizable surfaces on particle DEP behavior and surrounding liquid motion need not be negligible. As field frequency varies, grown features of DEP assembly structures ranging from low-frequency non-bridged gap to high-frequency single gold nanoparticle-made nanowires bridging the electrodes are demonstrated experimentally. Specifically, at 10 kHz, a kind of novel channel-like structure with parallel opposing banks is formed at the center of interelectrode gap. In stark contrast, at 1 MHz, thin PCF with diameter of 100 nm is created along the shortest distance of the isolation spacing. Moreover, a particular conductive path of nanoparticle chains is produced at 1 MHz in a DEP device embedded with multiple floating electrodes. A theoretical framework taking into account field-induced double-layer polarization at both the particle/electrolyte and electrode/electrolyte interface is developed to correlate these experimental observations with induced-charge electrokinetic (ICEK) phenomenon. And a RC circuit model is helpful in accounting for the formation of this particular non-bridged channel-like structure induced by a low-frequency AC voltage. As compared to thin PCF formed at high field frequency that effectively short circuits the electrode pair, though it is difficult for complete PCF bridging to occur at low frequency, the non-bridged conducting microstructure has potential to further miniaturize the size of electrode gap fabricated by standard micromachining process and may find useful application in biochemical sensing.
A framework for understanding cancer comparative effectiveness research data needs.
Carpenter, William R; Meyer, Anne-Marie; Abernethy, Amy P; Stürmer, Til; Kosorok, Michael R
2012-11-01
Randomized controlled trials remain the gold standard for evaluating cancer intervention efficacy. Randomized trials are not always feasible, practical, or timely and often don't adequately reflect patient heterogeneity and real-world clinical practice. Comparative effectiveness research can leverage secondary data to help fill knowledge gaps randomized trials leave unaddressed; however, comparative effectiveness research also faces shortcomings. The goal of this project was to develop a new model and inform an evolving framework articulating cancer comparative effectiveness research data needs. We examined prevalent models and conducted semi-structured discussions with 76 clinicians and comparative effectiveness research researchers affiliated with the Agency for Healthcare Research and Quality's cancer comparative effectiveness research programs. A new model was iteratively developed and presents cancer comparative effectiveness research and important measures in a patient-centered, longitudinal chronic care model better reflecting contemporary cancer care in the context of the cancer care continuum, rather than a single-episode, acute-care perspective. Immediately relevant for federally funded comparative effectiveness research programs, the model informs an evolving framework articulating cancer comparative effectiveness research data needs, including evolutionary enhancements to registries and epidemiologic research data systems. We discuss elements of contemporary clinical practice, methodology improvements, and related needs affecting comparative effectiveness research's ability to yield findings clinicians, policy makers, and stakeholders can confidently act on. Copyright © 2012 Elsevier Inc. All rights reserved.
A framework for understanding cancer comparative effectiveness research data needs
Carpenter, William R; Meyer, Anne-Marie; Abernethy, Amy P.; Stürmer, Til; Kosorok, Michael R.
2012-01-01
Objective Randomized controlled trials remain the gold standard for evaluating cancer intervention efficacy. Randomized trials are not always feasible, practical, or timely, and often don’t adequately reflect patient heterogeneity and real-world clinical practice. Comparative effectiveness research can leverage secondary data to help fill knowledge gaps randomized trials leave unaddressed; however, comparative effectiveness research also faces shortcomings. The goal of this project was to develop a new model and inform an evolving framework articulating cancer comparative effectiveness research data needs. Study Design and Setting We examined prevalent models and conducted semi-structured discussions with 76 clinicians and comparative effectiveness research researchers affiliated with the Agency for Healthcare Research and Quality’s cancer comparative effectiveness research programs. Results A new model was iteratively developed, and presents cancer comparative effectiveness research and important measures in a patient-centered, longitudinal chronic care model better-reflecting contemporary cancer care in the context of the cancer care continuum, rather than a single-episode, acute-care perspective. Conclusion Immediately relevant for federally-funded comparative effectiveness research programs, the model informs an evolving framework articulating cancer comparative effectiveness research data needs, including evolutionary enhancements to registries and epidemiologic research data systems. We discuss elements of contemporary clinical practice, methodology improvements, and related needs affecting comparative effectiveness research’s ability to yield findings clinicians, policymakers, and stakeholders can confidently act on. PMID:23017633
On the behaviour of biradicaloid [P(μ-NTer)]2 towards Lewis acids and bases.
Hinz, Alexander; Schulz, Axel; Villinger, Alexander
2016-05-07
The well-known diphosphadiazane-1,3-diyl [P(μ-NTer)]2 (Ter = 2,6-bis(2,4,6-trimethyl-phenyl)-phenyl) was treated with Lewis bases such as N-heterocyclic carbenes and Lewis acids e.g. gold(i) chloride complexes. In the reaction with the Lewis base, fragmentation of the P2N2 framework was observed, yielding a salt of the type [(NHC)2P](+)[(TerN)2P](-) in a clean reaction. The reaction of [P(μ-NTer)]2 with gold(i) chloride afforded 1 : 1 and 1 : 2 complexes. The dinuclear complex [(ClAu)2P(μ-NTer)2P] displays a bridging P atom between both gold centers, as has been observed for P based zwitterions.
Forecasting volatility in gold returns under the GARCH, IGARCH and FIGARCH frameworks: New evidence
NASA Astrophysics Data System (ADS)
Bentes, Sonia R.
2015-11-01
This study employs three volatility models of the GARCH family to examine the volatility behavior of gold returns. Much of the literature on this topic suggests that gold plays a fundamental role as a hedge and safe haven against adverse market conditions, which is particularly relevant in periods of high volatility. This makes understanding gold volatility important for a number of theoretical and empirical applications, namely investment valuation, portfolio selection, risk management, monetary policy-making, futures and option pricing, hedging strategies and value-at-risk (VaR) policies (e.g. Baur and Lucey (2010)). We use daily data from August 2, 1976 to February 6, 2015 and divide the full sample into two periods: the in-sample period (August 2, 1976-October 24, 2008) is used to estimate model coefficients, while the out-of-sample period (October 27, 2008-February 6, 2015) is for forecasting purposes. Specifically, we employ the GARCH(1,1), IGARCH(1,1) and FIGARCH(1, d,1) specifications. The results show that the FIGARCH(1, d,1) is the best model to capture linear dependence in the conditional variance of the gold returns as given by the information criteria. It is also found to be the best model to forecast the volatility of gold returns.
A novel 'Gold on Gold' biosensing scheme for an on-fiber immunoassay
NASA Astrophysics Data System (ADS)
Punjabi, N.; Satija, J.; Mukherji, S.
2015-05-01
In this paper, we propose a novel „gold on gold‟ biosensing scheme for absorbance based fiber-optic biosensor. First, a self-assembled monolayer of gold nanoparticles is formed at the sensing region of the fiber-optic probe by incubating an amino-silanized probe in a colloidal gold solution. Thereafter, the receptor moieties, i.e. Human immunoglobulin G (HIgG) were immobilized by using standard alkanethiol and classic carbodiimide coupling chemistry. Finally, biosensing experiments were performed with different concentrations of gold nanoparticle-tagged analyte, i.e. Goat anti- Human immunoglobulin G (Nanogold-GaHIgG). The sensor response was observed to be more than five-fold compared to the control bioassay, in which the sensor matrix was devoid of gold nanoparticle film. Also, the response was found to be ~10 times higher compared to the FITC-tagged scheme and ~14.5 times better compared to untagged scheme. This novel scheme also demonstrated the potential in improving the limit of detection for the fiber-optic biosensors.
Pagiatakis, Catherine; Tardif, Jean-Claude; L'Allier, Philippe L; Mongrain, Rosaire
2017-12-01
Interventional cardiologists still rely heavily on angiography for the evaluation of coronary lesion severity, despite its poor correlation with the presence of ischemia. In order to improve the accuracy of the current diagnostic procedures, an understanding of the relative influence of geometric characteristics on the induction of ischemia is required. This idea is especially important for coronary bifurcation lesions (CBLs), whose treatment is complex and is associated with high rates of peri- and post-procedural clinical events. Overall, it is unclear which geometric and morphological parameters of CBLs influence the onset of ischemia. More specifically, the effect of stenosis eccentricity is unknown. Computational fluid dynamic simulations, under a geometric multiscale framework, were executed for seven CBL configurations within the left main coronary artery bifurcation. Both concentric and eccentric stenosis profiles of mild to severe constriction were considered. By using a geometric multiscale framework, the fractional flow reserve, which is the gold-standard clinical diagnostic index, could be calculated and was compared between the eccentric and concentric profiles for each case. The results suggested that for configurations where the supplying vessel is stenosed, eccentricity could have a notable effect on and therefore be an important factor that influences configuration functionality.
Urovi, V; Jimenez-Del-Toro, O; Dubosson, F; Ruiz Torres, A; Schumacher, M I
2017-02-01
This paper describes a novel temporal logic-based framework for reasoning with continuous data collected from wearable sensors. The work is motivated by the Metabolic Syndrome, a cluster of conditions which are linked to obesity and unhealthy lifestyle. We assume that, by interpreting the physiological parameters of continuous monitoring, we can identify which patients have a higher risk of Metabolic Syndrome. We define temporal patterns for reasoning with continuous data and specify the coordination mechanisms for combining different sets of clinical guidelines that relate to this condition. The proposed solution is tested with data provided by twenty subjects, which used sensors for four days of continuous monitoring. The results are compared to the gold standard. The novelty of the framework stands in extending a temporal logic formalism, namely the Event Calculus, with temporal patterns. These patterns are helpful to specify the rules for reasoning with continuous data and in combining new knowledge into one consistent outcome that is tailored to the patient's profile. The overall approach opens new possibilities for delivering patient-tailored interventions and educational material before the patients present the symptoms of the disease. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Usman, M.; Atkinson, D.; Heathfield, E.; Greil, G.; Schaeffter, T.; Prieto, C.
2015-04-01
Two major challenges in cardiovascular MRI are long scan times due to slow MR acquisition and motion artefacts due to respiratory motion. Recently, a Motion Corrected-Compressed Sensing (MC-CS) technique has been proposed for free breathing 2D dynamic cardiac MRI that addresses these challenges by simultaneously accelerating MR acquisition and correcting for any arbitrary motion in a compressed sensing reconstruction. In this work, the MC-CS framework is combined with parallel imaging for further acceleration, and is termed Motion Corrected Sparse SENSE (MC-SS). Validation of the MC-SS framework is demonstrated in eight volunteers and three patients for left ventricular functional assessment and results are compared with the breath-hold acquisitions as reference. A non-significant difference (P > 0.05) was observed in the volumetric functional measurements (end diastolic volume, end systolic volume, ejection fraction) and myocardial border sharpness values obtained with the proposed and gold standard methods. The proposed method achieves whole heart multi-slice coverage in 2 min under free breathing acquisition eliminating the time needed between breath-holds for instructions and recovery. This results in two-fold speed up of the total acquisition time in comparison to the breath-hold acquisition.
Tan, Keson B; Nicholls, Jack I
2002-01-01
This study measured the gold screw preload at the gold cylinder-abutment screw joint interface obtained by 3 torque delivery systems. Using a precalibrated, strain-gauged standard abutment as the load cell, 3 torque delivery systems tested were shown to have significant differences in gold screw preload when a gold cylinder was attached. Mean preloads measured were 291.2 N for hand torque drivers set at 10 Ncm, 340.3 N for electronic torque controllers at low setting/10 Ncm, 384.4 N for electronic torque controllers at high setting/10 Ncm; and 140.8 N for hand-tightening with a prosthetic slot screwdriver. Significant differences in screw preload were also found between operators using a hand torque driver. Hand-tightening delivered insufficient preload and cannot be recommended for final gold screw tightening. Different electronic torque controller units set at 10 Ncm induced mean gold screw preloads that ranged from 264.1 N to as high as 501.2 N. Electronic torque controllers should be regularly recalibrated to ensure optimal output.
Schultheis, Stefan; Strub, Joerg R; Gerds, Thomas A; Guess, Petra C
2013-06-01
The authors analyzed the effect of fatigue on the survival rate and fracture load of monolithic and bi-layer CAD/CAM lithium-disilicate posterior three-unit fixed dental prostheses (FDPs) in comparison to the metal-ceramic gold standard. The authors divided 96 human premolars and molars into three equal groups. Lithium-disilicate ceramic (IPS-e.max-CAD) was milled with the CEREC-3-system in full-anatomic FDP dimensions (monolithic: M-LiCAD) or as framework (Bi-layer: BL-LiCAD) with subsequent hand-layer veneering. Metal-ceramic FDPs (MC) served as control. Single-load-to-failure tests were performed before and after mouth-motion fatigue. No fracture failures occurred during fatigue. Median fracture loads in [N], before and after fatigue were, respectively, as follows: M-LiCAD, 1,298/1,900; BL-LiCAD, 817/699; MC, 1,966/1,818. M-LiCAD and MC FPDs revealed comparable fracture loads and were both significantly higher than BL-LiCAD. M-LiCAD and BL-LiCAD both failed from core/veneer bulk fracture within the connector area. MC failures were limited to ceramic veneer fractures exposing the metal core. Fatigue had no significant effect on any group. Posterior monolithic CAD/CAM fabricated lithium-disilicate FPDs were shown to be fracture resistant with failure load results comparable to the metal-ceramic gold standard. Clinical investigations are needed to confirm these promising laboratory results. Monolithic CAD/CAM fabricated lithium-disilicate FDPs appeared to be a reliable treatment alternative for the posterior load-bearing area, whereas FDPs in bi-layer configuration were susceptible to low load fracture failure.
Boland, Mary Regina; Rusanov, Alexander; So, Yat; Lopez-Jimenez, Carlos; Busacca, Linda; Steinman, Richard C; Bakken, Suzanne; Bigger, J Thomas; Weng, Chunhua
2014-12-01
Underspecified user needs and frequent lack of a gold standard reference are typical barriers to technology evaluation. To address this problem, this paper presents a two-phase evaluation framework involving usability experts (phase 1) and end-users (phase 2). In phase 1, a cross-system functionality alignment between expert-derived user needs and system functions was performed to inform the choice of "the best available" comparison system to enable a cognitive walkthrough in phase 1 and a comparative effectiveness evaluation in phase 2. During phase 2, five quantitative and qualitative evaluation methods are mixed to assess usability: time-motion analysis, software log, questionnaires - System Usability Scale and the Unified Theory of Acceptance of Use of Technology, think-aloud protocols, and unstructured interviews. Each method contributes data for a unique measure (e.g., time motion analysis contributes task-completion-time; software log contributes action transition frequency). The measures are triangulated to yield complementary insights regarding user-perceived ease-of-use, functionality integration, anxiety during use, and workflow impact. To illustrate its use, we applied this framework in a formative evaluation of a software called Integrated Model for Patient Care and Clinical Trials (IMPACT). We conclude that this mixed-methods evaluation framework enables an integrated assessment of user needs satisfaction and user-perceived usefulness and usability of a novel design. This evaluation framework effectively bridges the gap between co-evolving user needs and technology designs during iterative prototyping and is particularly useful when it is difficult for users to articulate their needs for technology support due to the lack of a baseline. Copyright © 2013 Elsevier Inc. All rights reserved.
"Understanding" medical school curriculum content using KnowledgeMap.
Denny, Joshua C; Smithers, Jeffrey D; Miller, Randolph A; Spickard, Anderson
2003-01-01
To describe the development and evaluation of computational tools to identify concepts within medical curricular documents, using information derived from the National Library of Medicine's Unified Medical Language System (UMLS). The long-term goal of the KnowledgeMap (KM) project is to provide faculty and students with an improved ability to develop, review, and integrate components of the medical school curriculum. The KM concept identifier uses lexical resources partially derived from the UMLS (SPECIALIST lexicon and Metathesaurus), heuristic language processing techniques, and an empirical scoring algorithm. KM differentiates among potentially matching Metathesaurus concepts within a source document. The authors manually identified important "gold standard" biomedical concepts within selected medical school full-content lecture documents and used these documents to compare KM concept recognition with that of a known state-of-the-art "standard"-the National Library of Medicine's MetaMap program. The number of "gold standard" concepts in each lecture document identified by either KM or MetaMap, and the cause of each failure or relative success in a random subset of documents. For 4,281 "gold standard" concepts, MetaMap matched 78% and KM 82%. Precision for "gold standard" concepts was 85% for MetaMap and 89% for KM. The heuristics of KM accurately matched acronyms, concepts underspecified in the document, and ambiguous matches. The most frequent cause of matching failures was absence of target concepts from the UMLS Metathesaurus. The prototypic KM system provided an encouraging rate of concept extraction for representative medical curricular texts. Future versions of KM should be evaluated for their ability to allow administrators, lecturers, and students to navigate through the medical curriculum to locate redundancies, find interrelated information, and identify omissions. In addition, the ability of KM to meet specific, personal information needs should be assessed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Mary, E-mail: maryfeng@umich.ed; Moran, Jean M.; Koelling, Todd
2011-01-01
Purpose: Cardiac toxicity is an important sequela of breast radiotherapy. However, the relationship between dose to cardiac structures and subsequent toxicity has not been well defined, partially due to variations in substructure delineation, which can lead to inconsistent dose reporting and the failure to detect potential correlations. Here we have developed a heart atlas and evaluated its effect on contour accuracy and concordance. Methods and Materials: A detailed cardiac computed tomography scan atlas was developed jointly by cardiology, cardiac radiology, and radiation oncology. Seven radiation oncologists were recruited to delineate the whole heart, left main and left anterior descending interventricularmore » branches, and right coronary arteries on four cases before and after studying the atlas. Contour accuracy was assessed by percent overlap with gold standard atlas volumes. The concordance index was also calculated. Standard radiation fields were applied. Doses to observer-contoured cardiac structures were calculated and compared with gold standard contour doses. Pre- and post-atlas values were analyzed using a paired t test. Results: The cardiac atlas significantly improved contour accuracy and concordance. Percent overlap and concordance index of observer-contoured cardiac and gold standard volumes were 2.3-fold improved for all structures (p < 0.002). After application of the atlas, reported mean doses to the whole heart, left main artery, left anterior descending interventricular branch, and right coronary artery were within 0.1, 0.9, 2.6, and 0.6 Gy, respectively, of gold standard doses. Conclusions: This validated University of Michigan cardiac atlas may serve as a useful tool in future studies assessing cardiac toxicity and in clinical trials which include dose volume constraints to the heart.« less
Assessment of a novel biomechanical fracture model for distal radius fractures
2012-01-01
Background Distal radius fractures (DRF) are one of the most common fractures and often need surgical treatment, which has been validated through biomechanical tests. Currently a number of different fracture models are used, none of which resemble the in vivo fracture location. The aim of the study was to develop a new standardized fracture model for DRF (AO-23.A3) and compare its biomechanical behavior to the current gold standard. Methods Variable angle locking volar plates (ADAPTIVE, Medartis) were mounted on 10 pairs of fresh-frozen radii. The osteotomy location was alternated within each pair (New: 10 mm wedge 8 mm / 12 mm proximal to the dorsal / volar apex of the articular surface; Gold standard: 10 mm wedge 20 mm proximal to the articular surface). Each specimen was tested in cyclic axial compression (increasing load by 100 N per cycle) until failure or −3 mm displacement. Parameters assessed were stiffness, displacement and dissipated work calculated for each cycle and ultimate load. Significance was tested using a linear mixed model and Wald test as well as t-tests. Results 7 female and 3 male pairs of radii aged 74 ± 9 years were tested. In most cases (7/10), the two groups showed similar mechanical behavior at low loads with increasing differences at increasing loads. Overall the novel fracture model showed a significant different biomechanical behavior than the gold standard model (p < 0,001). The average final loads resisted were significantly lower in the novel model (860 N ± 232 N vs. 1250 N ± 341 N; p = 0.001). Conclusion The novel biomechanical fracture model for DRF more closely mimics the in vivo fracture site and shows a significantly different biomechanical behavior with increasing loads when compared to the current gold standard. PMID:23244634
Velupillai, Sumithra; Dalianis, Hercules; Hassel, Martin; Nilsson, Gunnar H
2009-12-01
Electronic patient records (EPRs) contain a large amount of information written in free text. This information is considered very valuable for research but is also very sensitive since the free text parts may contain information that could reveal the identity of a patient. Therefore, methods for de-identifying EPRs are needed. The work presented here aims to perform a manual and automatic Protected Health Information (PHI)-annotation trial for EPRs written in Swedish. This study consists of two main parts: the initial creation of a manually PHI-annotated gold standard, and the porting and evaluation of an existing de-identification software written for American English to Swedish in a preliminary automatic de-identification trial. Results are measured with precision, recall and F-measure. This study reports fairly high Inter-Annotator Agreement (IAA) results on the manually created gold standard, especially for specific tags such as names. The average IAA over all tags was 0.65 F-measure (0.84 F-measure highest pairwise agreement). For name tags the average IAA was 0.80 F-measure (0.91 F-measure highest pairwise agreement). Porting a de-identification software written for American English to Swedish directly was unfortunately non-trivial, yielding poor results. Developing gold standard sets as well as automatic systems for de-identification tasks in Swedish is feasible. However, discussions and definitions on identifiable information is needed, as well as further developments both on the tag sets and the annotation guidelines, in order to get a reliable gold standard. A completely new de-identification software needs to be developed.
Tidke, Pritish R; Gupta, Indarchand; Gade, Aniket K; Rai, Mahendra
2014-12-01
We report the extracellular biosynthesis of gold nanoparticles (AuNPs) using a fungus Fusarium acuminatum. Mycosynthesis of Au-NPs was carried out by challenging the fungal cells filtrate with HAuCl 4 solution (1 mM), as nanoparticles synthesizing enzyme secrete extracellularly by the fungi. The AuNPs were characterized with the help of UV-Visible spectrophotometer, Fourier Transform Infrared spectroscopy, Zeta Potential, X-ray diffraction (XRD) and Transmission electron microscopy (TEM). We observed absorbance peak in between 520 nm-550 nm corresponding to the surface plasmon absorbance of the gold nanoparticles. The nanoparticles synthesized in the present investigation were found to be capped by proteins. XRD results showed that the distinctive formation of crystalline gold nanoparticles in the solution. The spherical and polydispersed AuNPs in the range 8 to 28 nm with average size of 17 nm were observed by TEM analysis. We also standardized the parameters like the effect of pH, temperature and salt concentration on the biosynthesis of gold nanoparticles. It was found that acidic pH, 1 mM salt concentration and 37 (°)C temperature were found to be optimum for the synthesis of Au-NPs. Therefore, the present study introduces the easy, better and cheaper method for biosynthesis of AuNPs.
NASA Astrophysics Data System (ADS)
Dobrowolski, Ryszard; Mróz, Agnieszka; Dąbrowska, Marzena; Olszański, Piotr
2017-06-01
A novelty method for the determination of gold in geological samples by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry (SS HR CS GF AAS) after solid-phase extraction onto modified carbon nanotubes (CNT) was described. The methodology developed is based on solid phase extraction of Au(III) ions from digested samples to eliminate strong interference caused by iron compounds and problems related to inhomogeneities of the samples. The use of aqueous or solid standard for calibration was studied and the slope of calibration curve was the same for both of these modes. This statement indicates the possibility to perform the calibration of the method using aqueous standard solutions. Under optimum conditions the absolute detection limit for gold was equal to 2.24 · 10- 6 μg g- 1 while the adsorption capacity of modified carbon nanotubes was 264 mg g- 1. The proposed procedure was validated by the application of certified reference materials (CRMs) with different content of gold and different matrix, the results were in good agreement with certified values. The method was successfully applied for separation and determination of gold ions in complex geological samples, with precision generally better than 8%.
Taylor, Ulrike; Rehbock, Christoph; Streich, Carmen; Rath, Detlef; Barcikowski, Stephan
2014-09-01
Many studies have evaluated the toxicity of gold nanoparticles, although reliable predictions based on these results are rare. In order to overcome this problem, this article highlights strategies to improve comparability and standardization of nanotoxicological studies. To this end, it is proposed that we should adapt the nanomaterial to the addressed exposure scenario, using ligand-free nanoparticle references in order to differentiate ligand effects from size effects. Furthermore, surface-weighted particle dosing referenced to the biologically relevant parameter (e.g., cell number or organ mass) is proposed as the gold standard. In addition, it is recommended that we should shift the focus of toxicological experiments from 'live-dead' assays to the assessment of cell function, as this strategy allows observation of bioresponses at lower doses that are more relevant for in vivo scenarios.
NASA Astrophysics Data System (ADS)
Roy, Sam; Upton, Phaedra; Craw, Dave
2018-01-01
Formation of placer accumulations in fluvial environments requires 103-106 or even greater times concentration of heavy minerals. For this to occur, regular sediment supply from erosion of adjacent topography is required, the river should remain within a single course for an extended period of time and the material must be reworked such that a high proportion of the sediment is removed while a high proportion of the heavy minerals remains. We use numerical modeling, constrained by observations of circum-Pacific placer gold deposits, to explore processes occurring in evolving river systems in dynamic tectonic environments. A fluvial erosion/transport model is used to determine the mobility of placer gold under variable uplift rate, storm intensity, and rock mass strength conditions. Gold concentration is calculated from hydraulic and bedload grain size conditions. Model results suggest that optimal gold concentration occurs in river channels that frequently approach a threshold between detachment-limited and transport-limited hydraulic conditions. Such a condition enables the accumulation of gold particles within the framework of a residual gravel lag. An increase in transport capacity, which can be triggered by faster uplift rates, more resistant bedrock, or higher intensity storm events, will strip all bedload from the channel. Conversely, a reduction in transport capacity, triggered by a reduction in uplift rate, bedrock resistance, or storm intensity, will lead to a greater accumulation of a majority of sediments and a net decrease in gold concentration. For our model parameter range, the optimal conditions for placer gold concentration are met by 103 times difference in strength between bedrock and fault, uplift rates between 1 and 5 mm a-1, and moderate storm intensities. Fault damage networks are shown to be a critical factor for high Au concentrations and should be a target for exploration.
Suppressing unsteady flow in arterio-venous fistulae
NASA Astrophysics Data System (ADS)
Grechy, L.; Iori, F.; Corbett, R. W.; Shurey, S.; Gedroyc, W.; Duncan, N.; Caro, C. G.; Vincent, P. E.
2017-10-01
Arterio-Venous Fistulae (AVF) are regarded as the "gold standard" method of vascular access for patients with end-stage renal disease who require haemodialysis. However, a large proportion of AVF do not mature, and hence fail, as a result of various pathologies such as Intimal Hyperplasia (IH). Unphysiological flow patterns, including high-frequency flow unsteadiness, associated with the unnatural and often complex geometries of AVF are believed to be implicated in the development of IH. In the present study, we employ a Mesh Adaptive Direct Search optimisation framework, computational fluid dynamics simulations, and a new cost function to design a novel non-planar AVF configuration that can suppress high-frequency unsteady flow. A prototype device for holding an AVF in the optimal configuration is then fabricated, and proof-of-concept is demonstrated in a porcine model. Results constitute the first use of numerical optimisation to design a device for suppressing potentially pathological high-frequency flow unsteadiness in AVF.
Adapting Knowledge Translation Strategies for Rare Rheumatic Diseases.
Cellucci, Tania; Lee, Shirley; Webster, Fiona
2016-08-01
Rare rheumatic diseases present unique challenges to knowledge translation (KT) researchers. There is often an urgent need to transfer knowledge from research findings into clinical practice to facilitate earlier diagnosis and better outcomes. However, existing KT frameworks have not addressed the specific considerations surrounding rare diseases for which gold standard evidence is not available. Several widely adopted models provide guidance for processes and problems associated with KT. However, they do not address issues surrounding creation or synthesis of knowledge for rare diseases. Additional problems relate to lack of awareness or experience in intended knowledge users, low motivation, and potential barriers to changing practice or policy. Strategies to address the challenges of KT for rare rheumatic diseases include considering different levels of evidence available, linking knowledge creation and transfer directly, incorporating patient and physician advocacy efforts to generate awareness of conditions, and selecting strategies to address barriers to practice or policy change.
Measurement Scales of Suicidal Ideation and Attitudes: A Systematic Review Article
Ghasemi, Parvin; Shaghaghi, Abdolreza; Allahverdipour, Hamid
2015-01-01
Background: The main aim of this study was to accumulate research evidence that introduce validated scales to measure suicidal attitudes and ideation and provide an empirical framework for adopting a relevant assessment tool in studies on suicide and suicidal behaviors. Methods: Medical Subject Headings’ (MeSH) terms were used to search Ovid Medline, PROQUEST, Wiley online library, Science Direct and PubMed for the published articles in English that reported application of an scale to measure suicidal attitudes and ideation from January 1974 onward. Results: Fourteen suicidal attitude scale and 15 scales for assessing suicidal ideation were identified in this systematic review. No gold standard approach was recognized to study suicide related attitudes and ideations. Conclusion: Special focus on generally agreed dimensions of suicidal ideation and attitudes and cross-cultural validation of the introduced scales to be applicable in different ethnic and socially diverse populations could be a promising area of research for scholars. PMID:26634193
Using collective expert judgements to evaluate quality measures of mass spectrometry images.
Palmer, Andrew; Ovchinnikova, Ekaterina; Thuné, Mikael; Lavigne, Régis; Guével, Blandine; Dyatlov, Andrey; Vitek, Olga; Pineau, Charles; Borén, Mats; Alexandrov, Theodore
2015-06-15
Imaging mass spectrometry (IMS) is a maturating technique of molecular imaging. Confidence in the reproducible quality of IMS data is essential for its integration into routine use. However, the predominant method for assessing quality is visual examination, a time consuming, unstandardized and non-scalable approach. So far, the problem of assessing the quality has only been marginally addressed and existing measures do not account for the spatial information of IMS data. Importantly, no approach exists for unbiased evaluation of potential quality measures. We propose a novel approach for evaluating potential measures by creating a gold-standard set using collective expert judgements upon which we evaluated image-based measures. To produce a gold standard, we engaged 80 IMS experts, each to rate the relative quality between 52 pairs of ion images from MALDI-TOF IMS datasets of rat brain coronal sections. Experts' optional feedback on their expertise, the task and the survey showed that (i) they had diverse backgrounds and sufficient expertise, (ii) the task was properly understood, and (iii) the survey was comprehensible. A moderate inter-rater agreement was achieved with Krippendorff's alpha of 0.5. A gold-standard set of 634 pairs of images with accompanying ratings was constructed and showed a high agreement of 0.85. Eight families of potential measures with a range of parameters and statistical descriptors, giving 143 in total, were evaluated. Both signal-to-noise and spatial chaos-based measures performed highly with a correlation of 0.7 to 0.9 with the gold standard ratings. Moreover, we showed that a composite measure with the linear coefficients (trained on the gold standard with regularized least squares optimization and lasso) showed a strong linear correlation of 0.94 and an accuracy of 0.98 in predicting which image in a pair was of higher quality. The anonymized data collected from the survey and the Matlab source code for data processing can be found at: https://github.com/alexandrovteam/IMS_quality. © The Author 2015. Published by Oxford University Press.
Using collective expert judgements to evaluate quality measures of mass spectrometry images
Palmer, Andrew; Ovchinnikova, Ekaterina; Thuné, Mikael; Lavigne, Régis; Guével, Blandine; Dyatlov, Andrey; Vitek, Olga; Pineau, Charles; Borén, Mats; Alexandrov, Theodore
2015-01-01
Motivation: Imaging mass spectrometry (IMS) is a maturating technique of molecular imaging. Confidence in the reproducible quality of IMS data is essential for its integration into routine use. However, the predominant method for assessing quality is visual examination, a time consuming, unstandardized and non-scalable approach. So far, the problem of assessing the quality has only been marginally addressed and existing measures do not account for the spatial information of IMS data. Importantly, no approach exists for unbiased evaluation of potential quality measures. Results: We propose a novel approach for evaluating potential measures by creating a gold-standard set using collective expert judgements upon which we evaluated image-based measures. To produce a gold standard, we engaged 80 IMS experts, each to rate the relative quality between 52 pairs of ion images from MALDI-TOF IMS datasets of rat brain coronal sections. Experts’ optional feedback on their expertise, the task and the survey showed that (i) they had diverse backgrounds and sufficient expertise, (ii) the task was properly understood, and (iii) the survey was comprehensible. A moderate inter-rater agreement was achieved with Krippendorff’s alpha of 0.5. A gold-standard set of 634 pairs of images with accompanying ratings was constructed and showed a high agreement of 0.85. Eight families of potential measures with a range of parameters and statistical descriptors, giving 143 in total, were evaluated. Both signal-to-noise and spatial chaos-based measures performed highly with a correlation of 0.7 to 0.9 with the gold standard ratings. Moreover, we showed that a composite measure with the linear coefficients (trained on the gold standard with regularized least squares optimization and lasso) showed a strong linear correlation of 0.94 and an accuracy of 0.98 in predicting which image in a pair was of higher quality. Availability and implementation: The anonymized data collected from the survey and the Matlab source code for data processing can be found at: https://github.com/alexandrovteam/IMS_quality. Contact: theodore.alexandrov@embl.de PMID:26072506
Improving practice in community-based settings: a randomized trial of supervision - study protocol.
Dorsey, Shannon; Pullmann, Michael D; Deblinger, Esther; Berliner, Lucy; Kerns, Suzanne E; Thompson, Kelly; Unützer, Jürgen; Weisz, John R; Garland, Ann F
2013-08-10
Evidence-based treatments for child mental health problems are not consistently available in public mental health settings. Expanding availability requires workforce training. However, research has demonstrated that training alone is not sufficient for changing provider behavior, suggesting that ongoing intervention-specific supervision or consultation is required. Supervision is notably under-investigated, particularly as provided in public mental health. The degree to which supervision in this setting includes 'gold standard' supervision elements from efficacy trials (e.g., session review, model fidelity, outcome monitoring, skill-building) is unknown. The current federally-funded investigation leverages the Washington State Trauma-focused Cognitive Behavioral Therapy Initiative to describe usual supervision practices and test the impact of systematic implementation of gold standard supervision strategies on treatment fidelity and clinical outcomes. The study has two phases. We will conduct an initial descriptive study (Phase I) of supervision practices within public mental health in Washington State followed by a randomized controlled trial of gold standard supervision strategies (Phase II), with randomization at the clinician level (i.e., supervisors provide both conditions). Study participants will be 35 supervisors and 130 clinicians in community mental health centers. We will enroll one child per clinician in Phase I (N = 130) and three children per clinician in Phase II (N = 390). We use a multi-level mixed within- and between-subjects longitudinal design. Audio recordings of supervision and therapy sessions will be collected and coded throughout both phases. Child outcome data will be collected at the beginning of treatment and at three and six months into treatment. This study will provide insight into how supervisors can optimally support clinicians delivering evidence-based treatments. Phase I will provide descriptive information, currently unavailable in the literature, about commonly used supervision strategies in community mental health. The Phase II randomized controlled trial of gold standard supervision strategies is, to our knowledge, the first experimental study of gold standard supervision strategies in community mental health and will yield needed information about how to leverage supervision to improve clinician fidelity and client outcomes. ClinicalTrials.gov NCT01800266.
Extraction of gold (Au) particles from sea water by Delftia Acidovorans microbes
NASA Astrophysics Data System (ADS)
Yusoff, A. H. M.; Nading, M. E.; Salimi, M. N.
2017-10-01
Gold-mining activities have been an issue, especially when it involves in contamination of chemicals, for example arsenic and mercury. However, despite of these hazards, gold-mining activities are still being conducted. This is because the gold is worth, regardless of the problems. Gold-mining, as known needs a very large area of land, or site plant. Vast amount of labor force, mechanical force and fund are a must in order for the mining process to be continued. High demand of gold, made gold-mining industries as ones of the most profitable industries in the world. Thus, this has encouraged another alternative way to extract gold. At the mining site, researchers found that biomineralization of gold by Delftia acidovorans can be conducted. How it is done still cannot be understood. It is said that the bacteria secretes secondary metabolites, Delftibactin as a defensive mechanism against the toxicity of the soluble gold. Researchers try to find another source of elemental gold besides of the earth’s core. The options are either lava of a volcano or ocean. Here, the focus is seawater. The problem of seawater is that its composition still not yet to be proved. Dissolve gold existed as gold chloride in seawater, but in a very small amount. So, the gold separation should be focused, in order to make this process to be a successful one. Factors such as depth, climate, region, temperature need to be considered. If this difference affecting the separating process, standardized seawater composition have to be proposed.
Comparison of five methods for the estimation of methane production from vented in vitro systems.
Alvarez Hess, P S; Eckard, R J; Jacobs, J L; Hannah, M C; Moate, P J
2018-05-23
There are several methods for estimating methane production (MP) from feedstuffs in vented in vitro systems. One method (A; "gold standard") measures methane proportions in the incubation bottle's head space (HS) and in the vented gas collected in gas bags. Four other methods (B, C, D and E) measure methane proportion in a single gas sample from HS. Method B assumes the same methane proportion in the vented gas as in HS, method C assumes constant methane to carbon dioxide ratio, method D has been developed based on empirical data and method E assumes constant individual venting volumes. This study aimed to compare the MP predictions from these methods to that of the gold standard method under different incubation scenarios, to validate these methods based on their concordance with a gold standard method. Methods C, D and E had greater concordance (0.85, 0.88 and 0.81), lower root mean square error (RMSE) (0.80, 0.72 and 0.85) and lower mean bias (0.20, 0.35, -0.35) with the gold standard than did method B (concordance 0.67, RMSE 1.49 and mean bias 1.26). Methods D and E were simpler to perform than method C and method D was slightly more accurate than method E. Based on precision, accuracy and simplicity of implementation, it is recommended that, when method A cannot be used, methods D and E are preferred to estimate MP from vented in vitro systems. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Gold standards and expert panels: a pulmonary nodule case study with challenges and solutions
NASA Astrophysics Data System (ADS)
Miller, Dave P.; O'Shaughnessy, Kathryn F.; Wood, Susan A.; Castellino, Ronald A.
2004-05-01
Comparative evaluations of reader performance using different modalities, e.g. CT with computer-aided detection (CAD) vs. CT without CAD, generally require a "truth" definition based on a gold standard. There are many situations in which a true invariant gold standard is impractical or impossible to obtain. For instance, small pulmonary nodules are generally not assessed by biopsy or resection. In such cases, it is common to use a unanimous consensus or majority agreement from an expert panel as a reference standard for actionability in lieu of the unknown gold standard for disease. Nonetheless, there are three major concerns about expert panel reference standards: (1) actionability is not synonymous with disease (2) it may be possible to obtain different conclusions about which modality is better using different rules (e.g. majority vs. unanimous consensus), and (3) the variability associated with the panelists is not formally captured in the p-values or confidence intervals that are generally produced for estimating the extent to which one modality is superior to the other. A multi-reader-multi-case (MRMC) receiver operating characteristic (ROC) study was performed using 90 cases, 15 readers, and a reference truth based on 3 experienced panelists. The primary analyses were conducted using a reference truth of unanimous consensus regarding actionability (3 out of 3 panelists). To assess the three concerns noted above: (1) additional data from the original radiology reports were compared to the panel (2) the complete analysis was repeated using different definitions of truth, and (3) bootstrap analyses were conducted in which new truth panels were constructed by picking 1, 2, or 3 panelists at random. The definition of the reference truth affected the results for each modality (CT with CAD and CT without CAD) considered by itself, but the effects were similar, so the primary analysis comparing the modalities was robust to the choice of the reference truth.
NASA Astrophysics Data System (ADS)
Zhumagulov, Yaroslav V.; Krasavin, Andrey V.; Kashurnikov, Vladimir A.
2018-05-01
The method is developed for calculation of electronic properties of an ensemble of metal nanoclusters with the use of cluster perturbation theory. This method is applied to the system of gold nanoclusters. The Greens function of single nanocluster is obtained by ab initio calculations within the framework of the density functional theory, and then is used in Dyson equation to group nanoclusters together and to compute the Greens function as well as the electron density of states of the whole ensemble. The transition from insulator state of a single nanocluster to metallic state of bulk gold is observed.
Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays
NASA Astrophysics Data System (ADS)
Wahl, A.; Dawson, K.; Sassiat, N.; Quinn, A. J.; O'Riordan, A.
2011-08-01
This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H2SO4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu2+ nanomolar concentrations. Linear correlations were observed for increasing Cu2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.
Estimating disease prevalence in two-phase studies.
Alonzo, Todd A; Pepe, Margaret Sullivan; Lumley, Thomas
2003-04-01
Disease prevalence is ideally estimated using a 'gold standard' to ascertain true disease status on all subjects in a population of interest. In practice, however, the gold standard may be too costly or invasive to be applied to all subjects, in which case a two-phase design is often employed. Phase 1 data consisting of inexpensive and non-invasive screening tests on all study subjects are used to determine the subjects that receive the gold standard in the second phase. Naive estimates of prevalence in two-phase studies can be biased (verification bias). Imputation and re-weighting estimators are often used to avoid this bias. We contrast the forms and attributes of the various prevalence estimators. Distribution theory and simulation studies are used to investigate their bias and efficiency. We conclude that the semiparametric efficient approach is the preferred method for prevalence estimation in two-phase studies. It is more robust and comparable in its efficiency to imputation and other re-weighting estimators. It is also easy to implement. We use this approach to examine the prevalence of depression in adolescents with data from the Great Smoky Mountain Study.
Spencer, Bruce D
2012-06-01
Latent class models are increasingly used to assess the accuracy of medical diagnostic tests and other classifications when no gold standard is available and the true state is unknown. When the latent class is treated as the true class, the latent class models provide measures of components of accuracy including specificity and sensitivity and their complements, type I and type II error rates. The error rates according to the latent class model differ from the true error rates, however, and empirical comparisons with a gold standard suggest the true error rates often are larger. We investigate conditions under which the true type I and type II error rates are larger than those provided by the latent class models. Results from Uebersax (1988, Psychological Bulletin 104, 405-416) are extended to accommodate random effects and covariates affecting the responses. The results are important for interpreting the results of latent class analyses. An error decomposition is presented that incorporates an error component from invalidity of the latent class model. © 2011, The International Biometric Society.
NASA Astrophysics Data System (ADS)
Vogels, Sjoerd N.; Karman, Tijs; Kłos, Jacek; Besemer, Matthieu; Onvlee, Jolijn; van der Avoird, Ad; Groenenboom, Gerrit C.; van de Meerakker, Sebastiaan Y. T.
2018-02-01
Over the last 25 years, the formalism known as coupled-cluster (CC) theory has emerged as the method of choice for the ab initio calculation of intermolecular interaction potentials. The implementation known as CCSD(T) is often referred to as the gold standard in quantum chemistry. It gives excellent agreement with experimental observations for a variety of energy-transfer processes in molecular collisions, and it is used to calibrate density functional theory. Here, we present measurements of low-energy collisions between NO radicals and H2 molecules with a resolution that challenges the most sophisticated quantum chemistry calculations at the CCSD(T) level. Using hitherto-unexplored anti-seeding techniques to reduce the collision energy in a crossed-beam inelastic-scattering experiment, a resonance structure near 14 cm-1 is clearly resolved in the state-to-state integral cross-section, and a unique resonance fingerprint is observed in the corresponding differential cross-section. This resonance structure discriminates between two NO-H2 potentials calculated at the CCSD(T) level and pushes the required accuracy beyond the gold standard.
NASA Astrophysics Data System (ADS)
DSuryadi; Delyuzar; Soekimin
2018-03-01
Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.
Komine, Futoshi; Koizuka, Mai; Fushiki, Ryosuke; Taguchi, Kohei; Kamio, Shingo; Matsumura, Hideo
2013-09-01
To evaluate shear bond strength of a gingiva-colored indirect composite to three implant framework materials, before and after thermocycling, and verify the effect of surface pre-treatment for each framework. Commercially pure titanium (CP-Ti), American Dental Association (ADA) type 4 casting gold alloy (Type IV) and zirconia ceramics (Zirconia) were assessed. For each substrate, 96 disks were divided into six groups and primed with one of the following primers: Alloy Primer (ALP), Clearfil Photo Bond (CPB), Clearfil Photo Bond with Clearfil Porcelain Bond Activator (CPB+Activator), Estenia Opaque Primer (EOP), Metal Link (MLP) and V-Primer (VPR). The specimens were then bonded to a gingiva-colored indirect composite (Ceramage Concentrate GUM-D). Shear bond strengths were measured at 0 and 20 000 thermocycles and data were analyzed with the Steel-Dwass test and Mann-Whitney U-test. Shear bond strengths were significantly lower after thermocycling, with the exception of Type IV specimens primed with CPB (p = 0.092) or MLP (p = 0.112). For CP-Ti and Zirconia specimens, priming with CPB or CPB+Activator produced significantly higher bond strengths at 0 and 20 000 thermocycles, as compared with the other groups. For Type IV specimens, priming with ALP or MLP produced higher bond strengths at 0 and 20 000 thermocycles. Shear bond strength of a gingiva-colored indirect composite to CP-Ti, gold alloy and zirconia ceramics was generally lower after thermocycling. Application of a hydrophobic phosphate monomer and polymerization initiator was effective in maintaining bond strength of CP-Ti and zirconia ceramics. Combined use of a thione monomer and phosphoric monomer enhanced the durable bond strength of gold alloy.
Laser-driven shock compression of gold foam in the terapascal pressure range
NASA Astrophysics Data System (ADS)
Liu, Wei; Duan, Xiaoxi; Jiang, Shaoen; Wang, Zhebin; Sun, Liang; Liu, Hao; Yang, Weiming; Zhang, Huan; Ye, Qing; Wang, Peng; Li, Yulong; Yi, Lin; Dong, Suo
2018-06-01
Shock compression experiments are carried out on gold foam with an initial density of 3.2 g/cm3 through indirectly laser-driven shock waves at the SG-III prototype laser facility. The impedance-matching technique is applied to determine the equation-of-state (EOS) data of the shocked gold foam. A passive shock breakout diagnostic system is employed to obtain the shock velocities in both the standard material and gold foam. The gold foams are compressed to a maximum density of 20 g/cm3 under a shock pressure of about 2 TPa. The effects of the unsteadiness of shock waves on the EOS measurement are quantitatively analyzed and corrected. The correction of unsteady waves, as well as the good planarity of the shock waves and the low preheating of the gold foam, contributes high-confidence EOS data for the gold foam. The corrected experimental data are compared with the Hugoniot states from the SESAME library. The comparison suggests that the database is suitable for describing the states of gold foam with an initial density of 3.2 g/cm3 under a pressure of about 2 TPa.
Gold--a controversial sensitizer. European Environmental and Contact Dermatitis Research Group.
Bruze, M; Andersen, K E
1999-06-01
Until recently, gold allergy was considered to be extremely rare. Gold has been used and worshipped for thousands of years without any obvious complaints of skin problems, either in those participating in mining and other ways of prospecting, or in those wearing jewellery. When studies on contact allergy to gold sodium thiosulfate were published at the beginning of the 1990s, the allergic nature of the reported positive patch test reactions to gold was questioned. The major argument for such questioning was the lack of demonstrable clinical relevance in most positive reactors. A major reason for the questioning may have been confusion in differentiating between contact allergy and allergic contact dermatitis. To arrive at a diagnosis of allergic contact dermatitis, 3 steps have, in principle, to be fulfilled: (i) establishment of contact allergy; (ii) demonstration of present exposure; (iii) assessment of clinical relevance, i.e., causing or aggravating a contact dermatitis. In this paper, these steps are discussed with regard to gold. With our present knowledge of contact allergy-allergic contact dermatitis, we do not recommend including gold sodium thiosulfate in the standard series. It should be applied for scientific purposes and when allergic contact dermatitis from gold is suspected.
McHugh, J.B.
1984-01-01
A method has been developed using electrothermal atomization to effectively determine the amount of gold in natural water within the nanogram range. The method has four basic steps: (1) evaporating a 1-L sample; (2) putting it in hydrobromic acid-bromine solution; (3) extracting the sample with methyl-isobutyl-ketone; and (4) determining the amount of gold using an atomic absorption spectrophotometer. The limit of detection is 0.001 ??g gold per liter. Results from three studies indicate, respectively, that the method is precise, effective, and free of interference. Specifically, a precision study indicates that the method has a relative standard deviation of 16-18%; a recovery study indicates that the method recovers gold at an average of 93%; and an interference study indicates that the interference effects are eliminated with solvent extraction and background correction techniques. Application of the method to water samples collected from 41 sites throughout the Western United States and Alaska shows a gold concentration range of < 0.001 to 0.036 ??g gold per liter, with an average of 0.005 ??g/L. ?? 1984.
Bottom-up formation of robust gold carbide
Westenfelder, Benedikt; Biskupek, Johannes; Meyer, Jannik C.; Kurasch, Simon; Lin, Xiaohang; Scholz, Ferdinand; Gross, Axel; Kaiser, Ute
2015-01-01
A new phenomenon of structural reorganization is discovered and characterized for a gold-carbon system by in-situ atomic-resolution imaging at temperatures up to 1300 K. Here, a graphene sheet serves in three ways, as a quasi transparent substrate for aberration-corrected high-resolution transmission electron microscopy, as an in-situ heater, and as carbon supplier. The sheet has been decorated with gold nanoislands beforehand. During electron irradiation at 80 kV and at elevated temperatures, the accumulation of gold atoms has been observed on defective graphene sites or edges as well as at the facets of gold nanocrystals. Both resulted in clustering, forming unusual crystalline structures. Their lattice parameters and surface termination differ significantly from standard gold nanocrystals. The experimental data, supported by electron energy loss spectroscopy and density-functional theory calculations, suggests that isolated gold and carbon atoms form – under conditions of heat and electron irradiation – a novel type of compound crystal, Au-C in zincblende structure. The novel material is metastable, but surprisingly robust, even under annealing condition. PMID:25772348
Code of Federal Regulations, 2014 CFR
2014-10-01
... to the requirements of § 156.130(a). A standard plan at the bronze, silver, gold, or platinum level..., and a standard platinum plan, respectively. Zero cost sharing plan variation means, with respect to a...
Lebwohl, David; Kay, Andrea; Berg, William; Baladi, Jean Francois; Zheng, Ji
2009-01-01
In clinical trials of oncology drugs, overall survival (OS) is a direct measure of clinical efficacy and is considered the gold standard primary efficacy end point. The purpose of this study was to discuss the difficulties in using OS as a primary efficacy end point in the setting of evolving cancer therapies. We suggest that progression-free survival is an appropriate efficacy end point in many types of cancer, specifically those for which OS is expected to be prolonged and for which subsequent treatments are expected to affect OS.
Spaeth, George L; Reddy, Swathi C
2014-01-01
Optic disk imaging is integral to the diagnosis and treatment of patients with glaucoma. We discuss the various forms of imaging the optic nerve, including ophthalmoscopy, photography, and newer imaging modalities, including optical coherence tomography (OCT), confocal scanning laser ophthalmoscopy (HRT), and scanning laser polarimetry (GDx), specifically highlighting their benefits and disadvantages. We argue that ophthalmoscopy and photography remain the gold standard of imaging due to portability, ease of interpretation, and the presence of a large database of images for comparison. Copyright © 2014 Elsevier Inc. All rights reserved.
Breast-feeding, bottle-feeding and Dr. Spock: the shifting context of choice.
Knaak, Stephanie
2005-05-01
In today's environment, breast-feeding represents both a medical gold standard for infant feeding and a moral gold standard for mothering. The morally charged character of this discourse makes the notion of choice in infant feeding particularly problematic and fraught with difficulty. From an historical content analysis of selected editions from 1946 to 1998 of Dr. Spock's famous child-care manual, this paper explicates the process through which the breast versus bottle discourse has shifted over the last half-century, and how these shifts have shaped the context of choice within which mothers must make their infant-feeding decisions.
NASA Astrophysics Data System (ADS)
Ordonez, Robert F.; Mittemeyer, Bernhard T.; Aronoff, David R.; de Riese, Werner T. W.
2003-06-01
The use of minimally invasive treatments for benign prostatic hyperplasia (BPH) have been introduced into the medical community. Over the last decade several minimally invasive treatment techniques have been approved for use. In particular, interstitial laser coagulation (ILC) has shown pomise as an alternative to the current gold standard, transurethral resection of prostate (TURP). Studies show ILC to have equal efficacy as TURP while causing less side effects. Future technical advances as well as increased physician experience with ILC could lead to the replacement of TURP as the gold standard in trestment of BPH.
Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D
2014-03-01
Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.
Kahn, Michael G; Callahan, Tiffany J; Barnard, Juliana; Bauck, Alan E; Brown, Jeff; Davidson, Bruce N; Estiri, Hossein; Goerg, Carsten; Holve, Erin; Johnson, Steven G; Liaw, Siaw-Teng; Hamilton-Lopez, Marianne; Meeker, Daniella; Ong, Toan C; Ryan, Patrick; Shang, Ning; Weiskopf, Nicole G; Weng, Chunhua; Zozus, Meredith N; Schilling, Lisa
2016-01-01
Harmonized data quality (DQ) assessment terms, methods, and reporting practices can establish a common understanding of the strengths and limitations of electronic health record (EHR) data for operational analytics, quality improvement, and research. Existing published DQ terms were harmonized to a comprehensive unified terminology with definitions and examples and organized into a conceptual framework to support a common approach to defining whether EHR data is 'fit' for specific uses. DQ publications, informatics and analytics experts, managers of established DQ programs, and operational manuals from several mature EHR-based research networks were reviewed to identify potential DQ terms and categories. Two face-to-face stakeholder meetings were used to vet an initial set of DQ terms and definitions that were grouped into an overall conceptual framework. Feedback received from data producers and users was used to construct a draft set of harmonized DQ terms and categories. Multiple rounds of iterative refinement resulted in a set of terms and organizing framework consisting of DQ categories, subcategories, terms, definitions, and examples. The harmonized terminology and logical framework's inclusiveness was evaluated against ten published DQ terminologies. Existing DQ terms were harmonized and organized into a framework by defining three DQ categories: (1) Conformance (2) Completeness and (3) Plausibility and two DQ assessment contexts: (1) Verification and (2) Validation. Conformance and Plausibility categories were further divided into subcategories. Each category and subcategory was defined with respect to whether the data may be verified with organizational data, or validated against an accepted gold standard, depending on proposed context and uses. The coverage of the harmonized DQ terminology was validated by successfully aligning to multiple published DQ terminologies. Existing DQ concepts, community input, and expert review informed the development of a distinct set of terms, organized into categories and subcategories. The resulting DQ terms successfully encompassed a wide range of disparate DQ terminologies. Operational definitions were developed to provide guidance for implementing DQ assessment procedures. The resulting structure is an inclusive DQ framework for standardizing DQ assessment and reporting. While our analysis focused on the DQ issues often found in EHR data, the new terminology may be applicable to a wide range of electronic health data such as administrative, research, and patient-reported data. A consistent, common DQ terminology, organized into a logical framework, is an initial step in enabling data owners and users, patients, and policy makers to evaluate and communicate data quality findings in a well-defined manner with a shared vocabulary. Future work will leverage the framework and terminology to develop reusable data quality assessment and reporting methods.
Mid-infrared reflectlance spectra (2.3-22 micions) of sulfur, gold, KBr, MgO, and halon
NASA Technical Reports Server (NTRS)
Nash, D. B.
1986-01-01
Biconical diffuse reflectance spectra in the mid-infrared are presented for powder and other solid forms of sulfur, gold, potassium bromide, magnesium oxide, and halon. Comparisons are made with previously published results of other investigators, and recommendations are made regarding the relative usefulnees of these materials as reflectance standards in the mid-IR. Sulfur has strong intrinsic bands at wavelengths greater than 7 microns that must be taken into account for its use as a reflectance standard. Some sulfur samples have hydrocarbon contaminants and in powder form may have adsorbed water, both of which produce bands in the 3-4-micron region. Potassium bromide has several weak intrinsic bands and is very sensitive to adsorbed water contamination; otherwise it is a good IR reference material. Magnesium oxide and halon have major bands structure and low reflectivity at wavelengths greater than 2.6 microns and thus are unsuitable as reference materials in the mid-IR. Vapor-deposited gold on fine sandpaper (600 grit) is very bright, spectrally flat, and fairly diffuse, so it is the superior material (of those examined) for reflectance reference material throughout the IR. Fine gold powder, on the other hand, is much less bright than evaporated gold, and its reflectivity at wavelengths greater than its particle size is highly sensitive to particle packing density.
Aluminium-gold reference material for the k0-standardisation of neutron activation analysis
NASA Astrophysics Data System (ADS)
Ingelbrecht, C.; Peetermans, F.; De Corte, F.; De Wispelaere, A.; Vandecasteele, C.; Courtijn, E.; D'Hondt, P.
1991-05-01
Gold is an excellent comparator material for the k0-standardisation of neutron activation analysis because of its convenient and well defined nuclear properties. The most suitable form for a reference material is a dilute aluminium-gold alloy, for which the self-shielding effect for neutrons is small. Castings of composition Al-0.1 wt.% Au were prepared by crucible-less levitation melting, which gives close control of ingot composition with minimal contamination of the melt. The alloy composition was checked using induction-coupled plasma source emission spectrometry. The homogeneity of the alloy was measured by neutron activation analysis and a relative standard deviation of the gold content of 0.30% was found (10 mg samples). Metallography revealed a homogeneous distribution of AuAl 2 particles. The alloy was certified as Reference Material CBNM-530, with certified gold mass fraction 0.100±0.002 wt.%.
Quantitative Comparison of Photothermal Heat Generation between Gold Nanospheres and Nanorods.
Qin, Zhenpeng; Wang, Yiru; Randrianalisoa, Jaona; Raeesi, Vahid; Chan, Warren C W; Lipiński, Wojciech; Bischof, John C
2016-07-21
Gold nanoparticles (GNPs) are widely used for biomedical applications due to unique optical properties, established synthesis methods, and biological compatibility. Despite important applications of plasmonic heating in thermal therapy, imaging, and diagnostics, the lack of quantification in heat generation leads to difficulties in comparing the heating capability for new plasmonic nanostructures and predicting the therapeutic and diagnostic outcome. This study quantifies GNP heat generation by experimental measurements and theoretical predictions for gold nanospheres (GNS) and nanorods (GNR). Interestingly, the results show a GNP-type dependent agreement between experiment and theory. The measured heat generation of GNS matches well with theory, while the measured heat generation of GNR is only 30% of that predicted theoretically at peak absorption. This then leads to a surprising finding that the polydispersity, the deviation of nanoparticle size and shape from nominal value, significantly influences GNR heat generation (>70% reduction), while having a limited effect for GNS (<10% change). This work demonstrates that polydispersity is an important metric in quantitatively predicting plasmonic heat generation and provides a validated framework to quantitatively compare the heating capabilities between gold and other plasmonic nanostructures.
Quantitative Comparison of Photothermal Heat Generation between Gold Nanospheres and Nanorods
NASA Astrophysics Data System (ADS)
Qin, Zhenpeng; Wang, Yiru; Randrianalisoa, Jaona; Raeesi, Vahid; Chan, Warren C. W.; Lipiński, Wojciech; Bischof, John C.
2016-07-01
Gold nanoparticles (GNPs) are widely used for biomedical applications due to unique optical properties, established synthesis methods, and biological compatibility. Despite important applications of plasmonic heating in thermal therapy, imaging, and diagnostics, the lack of quantification in heat generation leads to difficulties in comparing the heating capability for new plasmonic nanostructures and predicting the therapeutic and diagnostic outcome. This study quantifies GNP heat generation by experimental measurements and theoretical predictions for gold nanospheres (GNS) and nanorods (GNR). Interestingly, the results show a GNP-type dependent agreement between experiment and theory. The measured heat generation of GNS matches well with theory, while the measured heat generation of GNR is only 30% of that predicted theoretically at peak absorption. This then leads to a surprising finding that the polydispersity, the deviation of nanoparticle size and shape from nominal value, significantly influences GNR heat generation (>70% reduction), while having a limited effect for GNS (<10% change). This work demonstrates that polydispersity is an important metric in quantitatively predicting plasmonic heat generation and provides a validated framework to quantitatively compare the heating capabilities between gold and other plasmonic nanostructures.
Tian, Chixia; Zhu, Liping; Lin, Feng; Boyes, Stephen G
2015-08-19
Imaging contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT) have received significant attention in the development of techniques for early stage cancer diagnosis. Gadolinium (Gd)(III), which has seven unpaired electrons and a large magnetic moment, can dramatically influence the water proton relaxation and hence exhibits excellent MRI contrast. On the other hand, gold (Au), which has a high atomic number and high X-ray attenuation coefficient, is an ideal contrast agent candidate for X-ray-based CT imaging. Gd metal-organic framework (MOF) nanoparticles with tunable size, high Gd(III) loading and multivalency can potentially overcome the limitations of clinically utilized Gd chelate contrast agents. In this work, we report for the first time the integration of GdMOF nanoparticles with gold nanoparticles (AuNPs) for the preparation of a MRI/CT bimodal imaging agent. Highly stable hybrid GdMOF/AuNPs composites have been prepared by using poly(acrylic acid) as a bridge between the GdMOF nanoparticles and AuNPs. The hybrid nanocomposites were then evaluated in MRI and CT imaging. The results revealed high longitudinal relaxivity in MRI and excellent CT imaging performance. Therefore, these GdMOF/AuNPs hybrid nanocomposites potentially provide a new platform for the development of multimodal imaging probes.
Tian, Chixia; Zhu, Liping; Lin, Feng; Boyes, Stephen G.
2015-01-01
Imaging contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT) have received significant attention in the development of techniques for early-stage cancer diagnosis. Gadolinium (Gd) (III), which has seven unpaired electrons and a large magnetic moment, can dramatically influence the water proton relaxation and hence exhibits excellent MRI contrast. On the other hand, gold (Au), which has a high atomic number and high x-ray attenuation coefficient, is an ideal contrast agent candidate for x-ray based CT imaging. Gd metal organic framework (MOF) nanoparticles with tunable size, high Gd (III) loading and multivalency can potentially overcome the limitations of clinically utilized Gd chelate contrast agents. In this work, we report for the first time the integration of GdMOF nanoparticles with gold nanoparticles (AuNPs) for the preparation of a MRI/CT bimodal imaging agent. Highly stable hybrid GdMOF/AuNPs composites have been prepared by using poly(acrylic acid) as a bridge between the GdMOF nanoparticles and AuNPs. The hybrid nanocomposites were then evaluated in MRI and CT imaging. The results revealed high longitudinal relaxivity in MRI and excellent CT imaging performance. Therefore, these GdMOF/AuNPs hybrid nanocomposites potentially provide a new platform for the development of multi-modal imaging probes. PMID:26147906
Performance evaluation of DNA copy number segmentation methods.
Pierre-Jean, Morgane; Rigaill, Guillem; Neuvial, Pierre
2015-07-01
A number of bioinformatic or biostatistical methods are available for analyzing DNA copy number profiles measured from microarray or sequencing technologies. In the absence of rich enough gold standard data sets, the performance of these methods is generally assessed using unrealistic simulation studies, or based on small real data analyses. To make an objective and reproducible performance assessment, we have designed and implemented a framework to generate realistic DNA copy number profiles of cancer samples with known truth. These profiles are generated by resampling publicly available SNP microarray data from genomic regions with known copy-number state. The original data have been extracted from dilutions series of tumor cell lines with matched blood samples at several concentrations. Therefore, the signal-to-noise ratio of the generated profiles can be controlled through the (known) percentage of tumor cells in the sample. This article describes this framework and its application to a comparison study between methods for segmenting DNA copy number profiles from SNP microarrays. This study indicates that no single method is uniformly better than all others. It also helps identifying pros and cons of the compared methods as a function of biologically informative parameters, such as the fraction of tumor cells in the sample and the proportion of heterozygous markers. This comparison study may be reproduced using the open source and cross-platform R package jointseg, which implements the proposed data generation and evaluation framework: http://r-forge.r-project.org/R/?group_id=1562. © The Author 2014. Published by Oxford University Press.
Armand, Mehran; Armiger, Robert S.; Kutzer, Michael D.; Basafa, Ehsan; Kazanzides, Peter; Taylor, Russell H.
2012-01-01
Intraoperative patient registration may significantly affect the outcome of image-guided surgery (IGS). Image-based registration approaches have several advantages over the currently dominant point-based direct contact methods and are used in some industry solutions in image-guided radiation therapy with fixed X-ray gantries. However, technical challenges including geometric calibration and computational cost have precluded their use with mobile C-arms for IGS. We propose a 2D/3D registration framework for intraoperative patient registration using a conventional mobile X-ray imager combining fiducial-based C-arm tracking and graphics processing unit (GPU)-acceleration. The two-stage framework 1) acquires X-ray images and estimates relative pose between the images using a custom-made in-image fiducial, and 2) estimates the patient pose using intensity-based 2D/3D registration. Experimental validations using a publicly available gold standard dataset, a plastic bone phantom and cadaveric specimens have been conducted. The mean target registration error (mTRE) was 0.34 ± 0.04 mm (success rate: 100%, registration time: 14.2 s) for the phantom with two images 90° apart, and 0.99 ± 0.41 mm (81%, 16.3 s) for the cadaveric specimen with images 58.5° apart. The experimental results showed the feasibility of the proposed registration framework as a practical alternative for IGS routines. PMID:22113773
Martins, Cristina; Dias, João; Pinto, José S
2014-01-01
Background Bariatric surgery is an important method for treatment of morbid obesity. It is known that significant nutritional deficiencies might occur after surgery, such as, calorie-protein malnutrition, iron deficiency anemia, and lack of vitamin B12, thiamine, and folic acid. Objective The objective of our study was to validate a computerized intelligent decision support system that suggests nutritional diagnoses of patients submitted to bariatric surgery. Methods There were fifteen clinical cases that were developed and sent to three dietitians in order to evaluate and define a nutritional diagnosis. After this step, the cases were sent to four bariatric surgery expert dietitians who were aiming to collaborate on a gold standard. The nutritional diagnosis was to be defined individually, and any disagreements were solved through a consensus. The final result was used as the gold standard. Bayesian networks were used to implement the system, and database training was done with Shell Netica. For the system validation, a similar answer rate was calculated, as well as the specificity and sensibility. Receiver operating characteristic (ROC) curves were projected to each nutritional diagnosis. Results Among the four experts, the rate of similar answers found was 80% (48/60) to 93% (56/60), depending on the nutritional diagnosis. The rate of similar answers of the system, compared to the gold standard, was 100% (60/60). The system sensibility and specificity were 95.0%. The ROC curves projection showed that the system was able to represent the expert knowledge (gold standard), and to help them in their daily tasks. Conclusions The system that was developed was validated to be used by health care professionals for decision-making support in their nutritional diagnosis of patients submitted to bariatric surgery. PMID:25601419
A smart all-in-one device to measure vital signs in admitted patients
van Goor, Harry; van Acht, Maartje; van de Belt, Tom H.; Bredie, Sebastian J. H.
2018-01-01
Background Vital sign measurements in hospitalized patients by nurses are time consuming and prone to operational errors. The Checkme, a smart all-in-one device capable of measuring vital signs, could improve daily patient monitoring by reducing measurement time, inter-observer variability, and incorrect inputs in the Electronic Health Record (EHR). We evaluated the accuracy of self measurements by patient using the Checkme in comparison with gold standard and nurse measurements. Methods and findings This prospective comparative study was conducted at the Internal Medicine ward of an academic hospital in the Netherlands. Fifty non-critically ill patients were enrolled in the study. Time-related measurement sessions were conducted on consecutive patients in a randomized order: vital sign measurement in duplicate by a well-trained investigator (gold standard), a Checkme measurement by the patient, and a routine vital sign measurement by a nurse. In 41 patients (82%), initial calibration of the Checkme was successful and results were eligible for analysis. In total, 69 sessions were conducted for these 41 patients. The temperature results recorded by the patient with the Checkme differed significantly from the gold standard core temperature measurements (mean difference 0.1 ± 0.3). Obtained differences in vital signs and calculated Modified Early Warning Score (MEWS) were small and were in range with predefined accepted discrepancies. Conclusions Patient-calculated MEWS using the Checkme, nurse measurements, and gold standard measurements all correlated well, and the small differences observed between modalities would not have affected clinical decision making. Using the Checkme, patients in a general medical ward setting are able to measure their own vital signs easily and accurately by themselves. This could be time saving for nurses and prevent errors due to manually entering data in the EHR. PMID:29432461
Tracking the hyoid bone in videofluoroscopic swallowing studies
NASA Astrophysics Data System (ADS)
Kellen, Patrick M.; Becker, Darci; Reinhardt, Joseph M.; van Daele, Douglas
2008-03-01
Difficulty swallowing, or dysphagia, has become a growing problem. Swallowing complications can lead to malnutrition, dehydration, respiratory infection, and even death. The current gold standard for analyzing and diagnosing dysphagia is the videofluoroscopic barium swallow study. In these studies, a fluoroscope is used to image the patient ingesting barium solutions of different volumes and viscosities. The hyoid bone anchors many key muscles involved in swallowing and plays a key role in the process. Abnormal hyoid bone motion during a swallow can indicate swallowing dysfunction. Currently in clinical settings, hyoid bone motion is assessed qualitatively, which can be subject to intra-rater and inter-rater bias. This paper presents a semi-automatic method for tracking the hyoid bone that makes quantitative analysis feasible. The user defines a template of the hyoid on one frame, and this template is tracked across subsequent frames. The matching phase is optimized by predicting the position of the template based on kinematics. An expert speech pathologist marked the position of the hyoid on each frame of ten studies to serve as the gold standard. Results from performing Bland-Altman analysis at a 95% confidence interval showed a bias of 0.0+/-0.08 pixels in x and -0.08+/-0.09 pixels in y between the manually-defined gold standard and the proposed method. The average Pearson's correlation between the gold standard and the proposed method was 0.987 in x and 0.980 in y. This paper also presents a method for automatically establishing a patient-centric coordinate system for the interpretation of hyoid motion. This coordinate system corrects for upper body patient motion during the study and identifies superior-inferior and anterior-posterior motion components. These tools make the use of quantitative hyoid motion analysis feasible in clinical and research settings.
Ren, H L; Li, J D; Miao, Y H; Xu, T
2018-03-01
Objective: To investigate the clinical application of glass micro fiber basophil activation test (BAT) used as a complementary test for house dust mite allergen. Method: Forty patients with clinical diagnosed allergic rhinitis was test by three methods for house dust mite allergen, skin prick test(SPT),Immuno CAP sIgE, and BAT in vitro. The sensitivity and specificity of glass micro fiber were accessed, and the consistency between BAT, SPT, and Immuno sIgE was analyzed. As in vivo provocation was not performed, gold standard is regarded as the combination of medical history and positive reports of SPT and/or ImmunoCAP sIgE test. Result: Twentythree patients are diagnosed as house dust mite allergic rhinitis by gold standard. The sensitivity and specificity of glass micro fiber BAT were 60.9% and 88.2%, the sensitivity of SPT and sIgE was 87.0% and sIgE 73.9%. The correlation rates between BAT with SPT is 0.67( P <0.05), and sIgE 0.55( P <0.05). The accuracy, predictive value of positive and negative of BAT are 0.47,60.9%,88.2%.The Kappa values of BAT, SPT and sIgE with gold standard are 0.47,0.86,0.71. Conclusion: As a complementary test for house dust mite allergic rhinitis, BAT have a good consistency with SPT and sIgE, while as it has only moderate consistency with "gold standard", further studies are needed to prove its clinical significance. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
A smart all-in-one device to measure vital signs in admitted patients.
Weenk, Mariska; van Goor, Harry; van Acht, Maartje; Engelen, Lucien Jlpg; van de Belt, Tom H; Bredie, Sebastian J H
2018-01-01
Vital sign measurements in hospitalized patients by nurses are time consuming and prone to operational errors. The Checkme, a smart all-in-one device capable of measuring vital signs, could improve daily patient monitoring by reducing measurement time, inter-observer variability, and incorrect inputs in the Electronic Health Record (EHR). We evaluated the accuracy of self measurements by patient using the Checkme in comparison with gold standard and nurse measurements. This prospective comparative study was conducted at the Internal Medicine ward of an academic hospital in the Netherlands. Fifty non-critically ill patients were enrolled in the study. Time-related measurement sessions were conducted on consecutive patients in a randomized order: vital sign measurement in duplicate by a well-trained investigator (gold standard), a Checkme measurement by the patient, and a routine vital sign measurement by a nurse. In 41 patients (82%), initial calibration of the Checkme was successful and results were eligible for analysis. In total, 69 sessions were conducted for these 41 patients. The temperature results recorded by the patient with the Checkme differed significantly from the gold standard core temperature measurements (mean difference 0.1 ± 0.3). Obtained differences in vital signs and calculated Modified Early Warning Score (MEWS) were small and were in range with predefined accepted discrepancies. Patient-calculated MEWS using the Checkme, nurse measurements, and gold standard measurements all correlated well, and the small differences observed between modalities would not have affected clinical decision making. Using the Checkme, patients in a general medical ward setting are able to measure their own vital signs easily and accurately by themselves. This could be time saving for nurses and prevent errors due to manually entering data in the EHR.
Church, Deirdre L; Ambasta, Anshula; Wilmer, Amanda; Williscroft, Holly; Ritchie, Gordon; Pillai, Dylan R; Champagne, Sylvie; Gregson, Daniel G
2015-01-01
BACKGROUND: Pneumocystis jirovecii (PJ), a pathogenic fungus, causes severe interstitial Pneumocystis pneumonia (PCP) among immunocompromised patients. A laboratory-developed real-time polyermase chain reaction (PCR) assay was validated for PJ detection to improve diagnosis of PCP. METHODS: Forty stored bronchoalveolar lavage (BAL) samples (20 known PJ positive [PJ+] and 20 known PJ negative [PJ−]) were initially tested using the molecular assay. Ninety-two sequentially collected BAL samples were then analyzed using an immunofluorescence assay (IFA) and secondarily tested using the PJ real-time PCR assay. Discrepant results were resolved by retesting BAL samples using another real-time PCR assay with a different target. PJ real-time PCR assay performance was compared with the existing gold standard (ie, IFA) and a modified gold standard, in which a true positive was defined as a sample that tested positive in two of three methods in a patient suspected to have PCP. RESULTS: Ninety of 132 (68%) BAL fluid samples were collected from immunocompromised patients. Thirteen of 92 (14%) BALs collected were PJ+ when tested using IFA. A total of 40 BAL samples were PJ+ in the present study including: all IFA positive samples (n=13); all referred PJ+ BAL samples (n=20); and seven additional BAL samples that were IFA negative, but positive using the modified gold standard. Compared with IFA, the PJ real-time PCR had sensitivity, specificity, and positive and negative predictive values of 100%, 91%, 65% and 100%, respectively. Compared with the modified gold standard, PJ real-time PCR had a sensitivity, specificity, and positive and negative predictive values of 100%. CONCLUSION: PJ real-time PCR improved detection of PJ in immunocompromised patients. PMID:26600815
Assessing operating characteristics of CAD algorithms in the absence of a gold standard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roy Choudhury, Kingshuk; Paik, David S.; Yi, Chin A.
2010-04-15
Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range ofmore » operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.« less
Mazeri, Stella; Sargison, Neil; Kelly, Robert F; Bronsvoort, Barend M deC; Handel, Ian
2016-01-01
The clinical and economic importance of fasciolosis has been recognised for centuries, yet diagnostic tests available for cattle are far from perfect. Test evaluation has mainly been carried out using gold standard approaches or under experimental settings, the limitations of which are well known. In this study, a Bayesian no gold standard approach was used to estimate the diagnostic sensitivity and specificity of five tests for fasciolosis in cattle. These included detailed liver necropsy including gall bladder egg count, faecal egg counting, a commercially available copro-antigen ELISA, an in-house serum excretory/secretory antibody ELISA and routine abattoir liver inspection. In total 619 cattle slaughtered at one of Scotland's biggest abattoirs were sampled, during three sampling periods spanning summer 2013, winter 2014 and autumn 2014. Test sensitivities and specificities were estimated using an extension of the Hui Walter no gold standard model, where estimates were allowed to vary between seasons if tests were a priori believed to perform differently for any reason. The results of this analysis provide novel information on the performance of these tests in a naturally infected cattle population and at different times of the year where different levels of acute or chronic infection are expected. Accurate estimates of sensitivity and specificity will allow for routine abattoir liver inspection to be used as a tool for monitoring the epidemiology of F. hepatica as well as evaluating herd health planning. Furthermore, the results provide evidence to suggest that the copro-antigen ELISA does not cross-react with Calicophoron daubneyi rumen fluke parasites, while the serum antibody ELISA does.
40 CFR 421.256 - Pretreatment standards for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for any 1 day Maximum for monthly average mg/troy ounce of gold refined electrolytically Lead 5.544 2... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078... Maximum for monthly average mg/troy ounce of silver reduced in solution Lead 0.112 0.052 Mercury 0.060 0...
40 CFR 421.256 - Pretreatment standards for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Maximum for monthly average mg/troy ounce of gold and silver smelted Lead 0.364 0.169 Mercury 0.195 0.078... Maximum for monthly average mg/troy ounce of silver reduced in solution Lead 0.112 0.052 Mercury 0.060 0... for any 1 day Maximum for monthly average mg/troy ounce of gold refined electrolytically Lead 5.544 2...
Absorption Spectra of Gold Nanoparticle Suspensions
NASA Astrophysics Data System (ADS)
Anan'eva, M. V.; Nurmukhametov, D. R.; Zverev, A. S.; Nelyubina, N. V.; Zvekov, A. A.; Russakov, D. M.; Kalenskii, A. V.; Eremenko, A. N.
2018-02-01
Three gold nanoparticle suspensions are obtained, and mean radii in distributions - (6.1 ± 0.2), (11.9 ± 0.3), and (17.3 ± 0.7) nm - are determined by the transmission electron microscopy method. The optical absorption spectra of suspensions are obtained and studied. Calculation of spectral dependences of the absorption index of suspensions at values of the gold complex refractive index taken from the literature showed a significant deviation of experimental and calculated data in the region of 450-800 nm. Spectral dependences of the absorption of suspensions are simulated within the framework of the Mie-Drude theory taking into account the interband absorption in the form of an additional term in the imaginary part of the dielectric permittivity of the Gaussian type. It is shown that to quantify the spectral dependences in the region of the plasmon absorption band of nanoparticles, correction of the parameters of the interband absorption is necessary in addition to the increase of the relaxation parameter of the Drude theory. Spectral dependences of the dielectric permittivity of gold in nanodimensional state are refined from the solution of the inverse problem. The results of the present work are important for predicting the special features of operation of photonic devices and optical detonators based on gold nanoparticles.
NASA Astrophysics Data System (ADS)
Separdar, L.; Davatolhagh, S.
2016-12-01
Molecular dynamics simulations at constant (N , V , T) are used to study the mutual effects of gold nanoparticles on the structure and dynamics of Kob-Andersen binary Lennard-Jones (BLJ) liquid within the framework of mode coupling theory of dynamic glass transition in the reciprocal space. The results show the 'softening' effect of the gold nanoparticles on the liquid dynamics in terms of (i) reducing the mode coupling crossover temperature Tc with respect to that of the bulk BLJ (i.e. BLJ without nanoparticles), (ii) decreasing the time interval of β-relaxation, and (iii) decreasing the exponent γ characterizing the power-law behavior of the α-relaxation time. This softening effect is explained in terms of the van der Waals attraction between the gold atoms comprising the nanoparticle and the BLJ host atoms, such that adsorption of host atoms onto the nanoparticle surface creates more space or free-volume for the other atoms to diffuse. By the same token interactions of purely excluded-volume-type are expected to result in the opposite effect. It is also noted that, much unlike BLJ host particles, the dynamics of gold nanoparticles is much less dependent on the wave-vector and that it exhibits a nearly exponential behavior in the α-relaxation regime.
Federal Criteria for Studies Grow
ERIC Educational Resources Information Center
Sparks, Sarah D.
2010-01-01
The author reports on the U.S. Department of Education's "What Works Clearinghouse" that goes beyond "gold standard" research and sets standards for accepting other types of studies. As part of the Institute of Education Sciences' push to make research more relevant to educators, the federal clearinghouse has devised standards by which it can…
Intrathoracic airway measurement: ex-vivo validation
NASA Astrophysics Data System (ADS)
Reinhardt, Joseph M.; Raab, Stephen A.; D'Souza, Neil D.; Hoffman, Eric A.
1997-05-01
High-resolution x-ray CT (HRCT) provides detailed images of the lungs and bronchial tree. HRCT-based imaging and quantitation of peripheral bronchial airway geometry provides a valuable tool for assessing regional airway physiology. Such measurements have been sued to address physiological questions related to the mechanics of airway collapse in sleep apnea, the measurement of airway response to broncho-constriction agents, and to evaluate and track the progression of disease affecting the airways, such as asthma and cystic fibrosis. Significant attention has been paid to the measurements of extra- and intra-thoracic airways in 2D sections from volumetric x-ray CT. A variety of manual and semi-automatic techniques have been proposed for airway geometry measurement, including the use of standardized display window and level settings for caliper measurements, methods based on manual or semi-automatic border tracing, and more objective, quantitative approaches such as the use of the 'half-max' criteria. A recently proposed measurements technique uses a model-based deconvolution to estimate the location of the inner and outer airway walls. Validation using a plexiglass phantom indicates that the model-based method is more accurate than the half-max approach for thin-walled structures. In vivo validation of these airway measurement techniques is difficult because of the problems in identifying a reliable measurement 'gold standard.' In this paper we report on ex vivo validation of the half-max and model-based methods using an excised pig lung. The lung is sliced into thin sections of tissue and scanned using an electron beam CT scanner. Airways of interest are measured from the CT images, and also measured with using a microscope and micrometer to obtain a measurement gold standard. The result show no significant difference between the model-based measurements and the gold standard; while the half-max estimates exhibited a measurement bias and were significantly different than the gold standard.
Sari, Mega M; Inoue, Takanobu; Matsumoto, Yoshitaka; Yokota, Kuriko
2016-01-01
This research is comparative study of gold mining and non-gold mining areas, using four community vulnerability indicators. Vulnerability indicators are exposure degree, contamination rate, chronic, and acute toxicity. Each indicator used different samples, such as wastewater from gold mining process, river water from Tajum river, human hair samples, and health questionnaire. This research used cold vapor atomic absorption spectrometry to determine total mercury concentration. The result showed that concentration of total mercury was 2,420 times than the maximum content of mercury permitted in wastewater based on the Indonesian regulation. Moreover, the mercury concentration in river water reached 685 ng/l, exceeding the quality threshold standards of the World Health Organization (WHO). The mercury concentration in hair samples obtained from the people living in the research location was considered to identify the health quality level of the people or as a chronic toxicity indicator. The highest mercury concentration--i.e. 17 ng/mg, was found in the gold mining respondents. Therefore, based on the total mercury concentration in the four indicators, the community in the gold mining area were more vulnerable to mercury than communities in non-gold mining areas. It was concluded that the community in gold mining area was more vulnerable to mercury contamination than the community in non-gold mining area.
Electrodeposition of gold particles on aluminum substrates containing copper.
Olson, Tim S; Atanassov, Plamen; Brevnov, Dmitri A
2005-01-27
Electrodeposition of adhesive metal films on aluminum is traditionally preceded by the zincate process, which activates the aluminum surface. This paper presents an alternative approach for activation of aluminum by using films containing 99.5% aluminum and 0.5% copper. Aluminum/copper films are made amenable for subsequent electrodeposition by anodization followed by chemical etching of aluminum oxide. The electrodeposition of gold is monitored with electrochemical impedance spectroscopy (EIS). Analysis of EIS data suggests that electrodeposition of gold increases the interfacial capacitance from values typical for electrodes with thin oxide layers to values typical for metal electrodes. Scanning electron microscopy examination of aluminum/copper films following gold electrodeposition shows the presence of gold particles with densities of 10(5)-10(7) particles cm(-2). The relative standard deviation of mean particle diameters is approximately 25%. Evaluation of the micrographs suggests that the electrodeposition occurs by instantaneous nucleation followed by growth of three-dimensional semispherical particles. The gold particles, which are electrically connected to the conductive aluminum/copper film, support a reversible faradaic process for a soluble redox couple. The deposited gold particles are suitable for subsequent metallization of aluminum and fabrication of particle-type films with interesting catalytic, electrical, and optical properties.
Brevnov, Dmitri A; Bungay, Corey
2005-08-04
Electrodeposition of gold mesoparticles on anodized and chemically etched aluminum/copper films deposited on silicon wafers proceeds by instantaneous nucleation and with no diffusion limitations. Both of these phenomena favor the formation of relatively monodispersed gold particles. Under the reported electrodeposition conditions, the relative standard deviation of the particle diameter is 25%. The particle coverage is 7 x 10(8) particles cm(-2). The mean particle diameter varies as a function of electrodeposition time in the range of 40-80 nm. Optical constants of gold mesoparticles are resolved by spectroscopic ellipsometry. A two-layer optical model is constructed to determine both extinction coefficients and refractive indexes of gold mesoparticles as a function of the mean particle diameter. The absorption peak, associated with surface plasmons, is modeled with two Lorentz oscillators. Absorption peak maximums shift from 610 to 675 nm as the mean particle diameter increases from 42 to 74 nm. Electrodeposition of gold particles on technologically relevant substrates, such as aluminum/copper films, is expected to increase the utility of gold particles and facilitate their incorporation in nanostructured materials and a variety of electronic and optical devices.
CommWalker: correctly evaluating modules in molecular networks in light of annotation bias.
Luecken, M D; Page, M J T; Crosby, A J; Mason, S; Reinert, G; Deane, C M
2018-03-15
Detecting novel functional modules in molecular networks is an important step in biological research. In the absence of gold standard functional modules, functional annotations are often used to verify whether detected modules/communities have biological meaning. However, as we show, the uneven distribution of functional annotations means that such evaluation methods favor communities of well-studied proteins. We propose a novel framework for the evaluation of communities as functional modules. Our proposed framework, CommWalker, takes communities as inputs and evaluates them in their local network environment by performing short random walks. We test CommWalker's ability to overcome annotation bias using input communities from four community detection methods on two protein interaction networks. We find that modules accepted by CommWalker are similarly co-expressed as those accepted by current methods. Crucially, CommWalker performs well not only in well-annotated regions, but also in regions otherwise obscured by poor annotation. CommWalker community prioritization both faithfully captures well-validated communities and identifies functional modules that may correspond to more novel biology. The CommWalker algorithm is freely available at opig.stats.ox.ac.uk/resources or as a docker image on the Docker Hub at hub.docker.com/r/lueckenmd/commwalker/. deane@stats.ox.ac.uk. Supplementary data are available at Bioinformatics online.
Interrater reliability of visually evaluated high frequency oscillations.
Spring, Aaron M; Pittman, Daniel J; Aghakhani, Yahya; Jirsch, Jeffrey; Pillay, Neelan; Bello-Espinosa, Luis E; Josephson, Colin; Federico, Paolo
2017-03-01
High frequency oscillations (HFOs) and interictal epileptiform discharges (IEDs) have been shown to be markers of epileptogenic regions. However, there is currently no 'gold standard' for identifying HFOs. Accordingly, we aimed to formally characterize the interrater reliability of HFO markings to validate the current practices. A morphology detector was implemented to detect events (candidate HFOs, lower-threshold events, and distractors) from the intracranial EEG (iEEG) of ten patients. Six electroencephalographers visually evaluated these events for the presence of HFOs and IEDs. Interrater reliability was calculated using pairwise Cohen's Kappa (κ) and intraclass correlation coefficients (ICC). The HFO evaluation distributions were significantly different for most pairs of reviewers (p<0.05; 11/15 pairs). Interrater reliability was poor for HFOs alone (κ mean =0.403; ICC=0.401) and HFO+IEDs (κ mean =0.568; ICC=0.570). The current practice of using two visual reviewers to identify HFOs is prone to bias arising from the poor agreement between reviewers, limiting the extrinsic validity of studies using these markers. The poor interrater reliability underlines the need for a framework to reconcile the important findings of existing studies. The present epoched design is an ideal candidate for the implementation of such a framework. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Gough, Larry P.; Day, Warren C.
2010-01-01
This report presents summary papers of work conducted between 2002 and 2007 under a 5-year project effort funded by the U.S. Geological Survey Mineral Resources Program, formerly entitled 'Tintina Metallogenic Province: Integrated Studies on Geologic Framework, Mineral Resources, and Environmental Signatures.' As the project progressed, the informal title changed from 'Tintina Metallogenic Province' project to 'Tintina Gold Province' project, the latter being more closely aligned with the terminology used by the mineral industry. As Goldfarb and others explain in the first chapter of this report, the Tintina Gold Province is a convenient term used by the mineral exploration community for a 'region of very varied geology, gold deposit types, and resource potential'. The Tintina Gold Province encompasses roughly 150,000 square kilometers, bounded by the Kaltag-Tintina fault system on the north and the Farewell-Denali fault system on the south. It extends westward in a broad arc, some 200 km wide, from northernmost British Columbia, through the Yukon, through southeastern and central Alaska, to southwestern Alaska. The climate is subarctic and, in Alaska, includes major physiographic delineations and ecoregions such as the Yukon-Tanana Upland, Tanana-Kuskokwim Lowlands, Yukon River Lowlands, and the Kuskokwim Mountains. Although the Tintina Gold Province is historically important for some of the very first placer and lode gold discoveries in northern North America, it has recently seen resurgence in mineral exploration, development, and mining activity. This resurgence is due to both new discoveries (for example, Pogo and Donlin Creek) and to the application of modern extraction methods to previously known, but economically restrictive, low-grade, bulk-tonnage gold resources (for example, Fort Knox, Clear Creek, and Scheelite Dome). In addition, the Tintina Gold Province hosts numerous other mineral deposit types, possessing both high and low sulfide content, which are not currently in development.
Groves, D.I.; Goldfarb, R.J.; Robert, F.; Hart, C.J.R.
2003-01-01
Metamorphic belts are complex regions where accretion or collision has added to, or thickened, continental crust. Gold-rich deposits can be formed at all stages of orogen evolution, so that evolving metamorphic belts contain diverse gold deposit types that may be juxtaposed or overprint each other. This partly explains the high level of controversy on the origin of some deposit types, particularly those formed or overprinted/remobilized during the major compressional orogeny that shaped the final geometry of the hosting metamorphic belts. These include gold-dominated orogenic and intrusion-related deposits, but also particularly controversial gold deposits with atypical metal associations. There are a number of outstanding problems for all types of gold deposits in metamorphc belts. These include the following: (1) definitive classifications, (2) unequivocal recognition of fluid and metal sources, (3) understanding of fluid migration and focusing at all scales, (4) resolution of the precise role of granitoid magmatism, (5) precise gold-depositional mechanisms, particularly those producing high gold grades, and (6) understanding of the release of CO2-rich fluids from subducting slabs and subcreted oceanic crust and granitoid magmas at different crustal levels. Research needs to be better coordinated and more integrated, such that detailed fluid-inclusion, trace-element, and isotopic studies of both gold deposits and potential source rocks, using cutting-edge technology, are embedded in a firm geological framework at terrane to deposit scales. Ultimately, four-dimensional models need to be developed, involving high-quality, three-dimensional geological data combined with integrated chemical and fluid-flow modeling, to understand the total history of the hydrothermal systems involved. Such research, particularly that which can predict superior targets visible in data sets available to exploration companies before discovery, has obvious spin-offs for global- to deposit-scale targeting of deposits with superior size and grade in the covered terranes that will be the exploration focus of the twenty-first century.
Briegel, Ariane; Pilhofer, Martin; Mastronarde, David N.; Jensen, Grant J.
2013-01-01
The apparent handedness of an EM-tomography reconstruction depends on a number of conventions and can be confused in many ways. As the number of different hardware and software combinations being used for electron tomography continue to climb, and the reconstructions being produced reach higher and higher resolutions, the need to verify the hand of the results has increased. Here we enumerate various steps in a typical tomography experiment that affect handedness and show that DNA origami gold nanoparticle helices can be used as convenient and fail-safe handedness standards. PMID:23639902
Batra, U; Parikh, P M; Prabhash, K; Tongaonkar, H B; Chibber, P; Dabkara, D; Deshmukh, C; Ghadyalpatil, N; Hingmire, S; Joshi, A; Raghunath, S K; Rajappa, S; Rajendranath, R; Rawal, S K; Singh, Manisha; Singh, R; Somashekhar, S P; Sood, R
2016-01-01
The Oncology Gold Standard (OGS) Expert Group on renal cell carcinoma (RCC) developed the consensus statement to provide community oncologists practical guidelines on the management of advanced clear cell (cc) RCC using published evidence, practical experience of experts in real life management, and results of a nationwide survey involving 144 health-care professionals. Six broad question categories containing 33 unique questions cover major situations in the routine management of RCC. This document serves as a ready guide for the standard of care to optimize outcome. The table of "Take Home Messages" at the end is a convenient tool for busy practitioners.
Probabilistic brain tissue segmentation in neonatal magnetic resonance imaging.
Anbeek, Petronella; Vincken, Koen L; Groenendaal, Floris; Koeman, Annemieke; van Osch, Matthias J P; van der Grond, Jeroen
2008-02-01
A fully automated method has been developed for segmentation of four different structures in the neonatal brain: white matter (WM), central gray matter (CEGM), cortical gray matter (COGM), and cerebrospinal fluid (CSF). The segmentation algorithm is based on information from T2-weighted (T2-w) and inversion recovery (IR) scans. The method uses a K nearest neighbor (KNN) classification technique with features derived from spatial information and voxel intensities. Probabilistic segmentations of each tissue type were generated. By applying thresholds on these probability maps, binary segmentations were obtained. These final segmentations were evaluated by comparison with a gold standard. The sensitivity, specificity, and Dice similarity index (SI) were calculated for quantitative validation of the results. High sensitivity and specificity with respect to the gold standard were reached: sensitivity >0.82 and specificity >0.9 for all tissue types. Tissue volumes were calculated from the binary and probabilistic segmentations. The probabilistic segmentation volumes of all tissue types accurately estimated the gold standard volumes. The KNN approach offers valuable ways for neonatal brain segmentation. The probabilistic outcomes provide a useful tool for accurate volume measurements. The described method is based on routine diagnostic magnetic resonance imaging (MRI) and is suitable for large population studies.
Acquisition and evaluation of verb subcategorization resources for biomedicine.
Rimell, Laura; Lippincott, Thomas; Verspoor, Karin; Johnson, Helen L; Korhonen, Anna
2013-04-01
Biomedical natural language processing (NLP) applications that have access to detailed resources about the linguistic characteristics of biomedical language demonstrate improved performance on tasks such as relation extraction and syntactic or semantic parsing. Such applications are important for transforming the growing unstructured information buried in the biomedical literature into structured, actionable information. In this paper, we address the creation of linguistic resources that capture how individual biomedical verbs behave. We specifically consider verb subcategorization, or the tendency of verbs to "select" co-occurrence with particular phrase types, which influences the interpretation of verbs and identification of verbal arguments in context. There are currently a limited number of biomedical resources containing information about subcategorization frames (SCFs), and these are the result of either labor-intensive manual collation, or automatic methods that use tools adapted to a single biomedical subdomain. Either method may result in resources that lack coverage. Moreover, the quality of existing verb SCF resources for biomedicine is unknown, due to a lack of available gold standards for evaluation. This paper presents three new resources related to verb subcategorization frames in biomedicine, and four experiments making use of the new resources. We present the first biomedical SCF gold standards, capturing two different but widely-used definitions of subcategorization, and a new SCF lexicon, BioCat, covering a large number of biomedical sub-domains. We evaluate the SCF acquisition methodologies for BioCat with respect to the gold standards, and compare the results with the accuracy of the only previously existing automatically-acquired SCF lexicon for biomedicine, the BioLexicon. Our results show that the BioLexicon has greater precision while BioCat has better coverage of SCFs. Finally, we explore the definition of subcategorization using these resources and its implications for biomedical NLP. All resources are made publicly available. The SCF resources we have evaluated still show considerably lower accuracy than that reported with general English lexicons, demonstrating the need for domain- and subdomain-specific SCF acquisition tools for biomedicine. Our new gold standards reveal major differences when annotators use the different definitions. Moreover, evaluation of BioCat yields major differences in accuracy depending on the gold standard, demonstrating that the definition of subcategorization adopted will have a direct impact on perceived system accuracy for specific tasks. Copyright © 2013 Elsevier Inc. All rights reserved.
Breast density quantification with cone-beam CT: A post-mortem study
Johnson, Travis; Ding, Huanjun; Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee
2014-01-01
Forty post-mortem breasts were imaged with a flat-panel based cone-beam x-ray CT system at 50 kVp. The feasibility of breast density quantification has been investigated using standard histogram thresholding and an automatic segmentation method based on the fuzzy c-means algorithm (FCM). The breasts were chemically decomposed into water, lipid, and protein immediately after image acquisition was completed. The percent fibroglandular volume (%FGV) from chemical analysis was used as the gold standard for breast density comparison. Both image-based segmentation techniques showed good precision in breast density quantification with high linear coefficients between the right and left breast of each pair. When comparing with the gold standard using %FGV from chemical analysis, Pearson’s r-values were estimated to be 0.983 and 0.968 for the FCM clustering and the histogram thresholding techniques, respectively. The standard error of the estimate (SEE) was also reduced from 3.92% to 2.45% by applying the automatic clustering technique. The results of the postmortem study suggested that breast tissue can be characterized in terms of water, lipid and protein contents with high accuracy by using chemical analysis, which offers a gold standard for breast density studies comparing different techniques. In the investigated image segmentation techniques, the FCM algorithm had high precision and accuracy in breast density quantification. In comparison to conventional histogram thresholding, it was more efficient and reduced inter-observer variation. PMID:24254317
Improving practice in community-based settings: a randomized trial of supervision – study protocol
2013-01-01
Background Evidence-based treatments for child mental health problems are not consistently available in public mental health settings. Expanding availability requires workforce training. However, research has demonstrated that training alone is not sufficient for changing provider behavior, suggesting that ongoing intervention-specific supervision or consultation is required. Supervision is notably under-investigated, particularly as provided in public mental health. The degree to which supervision in this setting includes ‘gold standard’ supervision elements from efficacy trials (e.g., session review, model fidelity, outcome monitoring, skill-building) is unknown. The current federally-funded investigation leverages the Washington State Trauma-focused Cognitive Behavioral Therapy Initiative to describe usual supervision practices and test the impact of systematic implementation of gold standard supervision strategies on treatment fidelity and clinical outcomes. Methods/Design The study has two phases. We will conduct an initial descriptive study (Phase I) of supervision practices within public mental health in Washington State followed by a randomized controlled trial of gold standard supervision strategies (Phase II), with randomization at the clinician level (i.e., supervisors provide both conditions). Study participants will be 35 supervisors and 130 clinicians in community mental health centers. We will enroll one child per clinician in Phase I (N = 130) and three children per clinician in Phase II (N = 390). We use a multi-level mixed within- and between-subjects longitudinal design. Audio recordings of supervision and therapy sessions will be collected and coded throughout both phases. Child outcome data will be collected at the beginning of treatment and at three and six months into treatment. Discussion This study will provide insight into how supervisors can optimally support clinicians delivering evidence-based treatments. Phase I will provide descriptive information, currently unavailable in the literature, about commonly used supervision strategies in community mental health. The Phase II randomized controlled trial of gold standard supervision strategies is, to our knowledge, the first experimental study of gold standard supervision strategies in community mental health and will yield needed information about how to leverage supervision to improve clinician fidelity and client outcomes. Trial registration ClinicalTrials.gov NCT01800266 PMID:23937766
Kahn, Michael G.; Callahan, Tiffany J.; Barnard, Juliana; Bauck, Alan E.; Brown, Jeff; Davidson, Bruce N.; Estiri, Hossein; Goerg, Carsten; Holve, Erin; Johnson, Steven G.; Liaw, Siaw-Teng; Hamilton-Lopez, Marianne; Meeker, Daniella; Ong, Toan C.; Ryan, Patrick; Shang, Ning; Weiskopf, Nicole G.; Weng, Chunhua; Zozus, Meredith N.; Schilling, Lisa
2016-01-01
Objective: Harmonized data quality (DQ) assessment terms, methods, and reporting practices can establish a common understanding of the strengths and limitations of electronic health record (EHR) data for operational analytics, quality improvement, and research. Existing published DQ terms were harmonized to a comprehensive unified terminology with definitions and examples and organized into a conceptual framework to support a common approach to defining whether EHR data is ‘fit’ for specific uses. Materials and Methods: DQ publications, informatics and analytics experts, managers of established DQ programs, and operational manuals from several mature EHR-based research networks were reviewed to identify potential DQ terms and categories. Two face-to-face stakeholder meetings were used to vet an initial set of DQ terms and definitions that were grouped into an overall conceptual framework. Feedback received from data producers and users was used to construct a draft set of harmonized DQ terms and categories. Multiple rounds of iterative refinement resulted in a set of terms and organizing framework consisting of DQ categories, subcategories, terms, definitions, and examples. The harmonized terminology and logical framework’s inclusiveness was evaluated against ten published DQ terminologies. Results: Existing DQ terms were harmonized and organized into a framework by defining three DQ categories: (1) Conformance (2) Completeness and (3) Plausibility and two DQ assessment contexts: (1) Verification and (2) Validation. Conformance and Plausibility categories were further divided into subcategories. Each category and subcategory was defined with respect to whether the data may be verified with organizational data, or validated against an accepted gold standard, depending on proposed context and uses. The coverage of the harmonized DQ terminology was validated by successfully aligning to multiple published DQ terminologies. Discussion: Existing DQ concepts, community input, and expert review informed the development of a distinct set of terms, organized into categories and subcategories. The resulting DQ terms successfully encompassed a wide range of disparate DQ terminologies. Operational definitions were developed to provide guidance for implementing DQ assessment procedures. The resulting structure is an inclusive DQ framework for standardizing DQ assessment and reporting. While our analysis focused on the DQ issues often found in EHR data, the new terminology may be applicable to a wide range of electronic health data such as administrative, research, and patient-reported data. Conclusion: A consistent, common DQ terminology, organized into a logical framework, is an initial step in enabling data owners and users, patients, and policy makers to evaluate and communicate data quality findings in a well-defined manner with a shared vocabulary. Future work will leverage the framework and terminology to develop reusable data quality assessment and reporting methods. PMID:27713905
Ou, Yiming; Wang, Xiaohui; Lai, Keqiang; Huang, Yiqun; Rasco, Barbara A; Fan, Yuxia
2018-03-21
Synthetic colorants in food can be a potential threat to human health. In this study, surface-enhanced Raman spectroscopy (SERS) coupled with gold nanorods as substrates is proposed to analyze allura red and sunset yellow in beverages. The gold nanorods with different aspect ratios were synthesized, and their long-term stability, SERS activity, and the effect of the different salts on the SERS signal were investigated. The results demonstrate that gold nanorods have a satisfactory stability (stored up to 28 days). SERS coupled with gold nanorods exhibit stronger sensitivity. MgSO 4 was chosen to improve the SERS signal of sunset yellow, and no salts could enhance the SERS signal of allura red. The lowest concentration was 0.10 mg/L for both colorant standard solutions. The successful prediction results using SERS were much closer to those obtained by high-performance liquid chromatography for the sample in beverages. SERS combined with gold nanorods shows potential for analyzing food colorants and other food additives as a rapid, convenient, and sensitive method.
Business Education. Vocational Education Program Courses Standards.
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. Div. of Vocational, Adult, and Community Education.
This document contains vocational education program courses standards (curriculum frameworks and student performance standards) for business technology education programs in Florida. Each program courses standard is composed of two parts: a curriculum framework and student performance standards. The curriculum framework includes four major…
McDermott, A; Visentin, G; De Marchi, M; Berry, D P; Fenelon, M A; O'Connor, P M; Kenny, O A; McParland, S
2016-04-01
The aim of this study was to evaluate the effectiveness of mid-infrared spectroscopy in predicting milk protein and free amino acid (FAA) composition in bovine milk. Milk samples were collected from 7 Irish research herds and represented cows from a range of breeds, parities, and stages of lactation. Mid-infrared spectral data in the range of 900 to 5,000 cm(-1) were available for 730 milk samples; gold standard methods were used to quantify individual protein fractions and FAA of these samples with a view to predicting these gold standard protein fractions and FAA levels with available mid-infrared spectroscopy data. Separate prediction equations were developed for each trait using partial least squares regression; accuracy of prediction was assessed using both cross validation on a calibration data set (n=400 to 591 samples) and external validation on an independent data set (n=143 to 294 samples). The accuracy of prediction in external validation was the same irrespective of whether undertaken on the entire external validation data set or just within the Holstein-Friesian breed. The strongest coefficient of correlation obtained for protein fractions in external validation was 0.74, 0.69, and 0.67 for total casein, total β-lactoglobulin, and β-casein, respectively. Total proteins (i.e., total casein, total whey, and total lactoglobulin) were predicted with greater accuracy then their respective component traits; prediction accuracy using the infrared spectrum was superior to prediction using just milk protein concentration. Weak to moderate prediction accuracies were observed for FAA. The greatest coefficient of correlation in both cross validation and external validation was for Gly (0.75), indicating a moderate accuracy of prediction. Overall, the FAA prediction models overpredicted the gold standard values. Near-unity correlations existed between total casein and β-casein irrespective of whether the traits were based on the gold standard (0.92) or mid-infrared spectroscopy predictions (0.95). Weaker correlations among FAA were observed than the correlations among the protein fractions. Pearson correlations between gold standard protein fractions and the milk processing characteristics of rennet coagulation time, curd firming time, curd firmness, heat coagulating time, pH, and casein micelle size were weak to moderate and ranged from -0.48 (protein and pH) to 0.50 (total casein and a30). Pearson correlations between gold standard FAA and these milk processing characteristics were also weak to moderate and ranged from -0.60 (Val and pH) to 0.49 (Val and K20). Results from this study indicate that mid-infrared spectroscopy has the potential to predict protein fractions and some FAA in milk at a population level. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Machine Learning to Improve the Effectiveness of ANRS in Predicting HIV Drug Resistance.
Singh, Yashik
2017-10-01
Human immunodeficiency virus infection and acquired immune deficiency syndrome (HIV/AIDS) is one of the major burdens of disease in developing countries, and the standard-of-care treatment includes prescribing antiretroviral drugs. However, antiretroviral drug resistance is inevitable due to selective pressure associated with the high mutation rate of HIV. Determining antiretroviral resistance can be done by phenotypic laboratory tests or by computer-based interpretation algorithms. Computer-based algorithms have been shown to have many advantages over laboratory tests. The ANRS (Agence Nationale de Recherches sur le SIDA) is regarded as a gold standard in interpreting HIV drug resistance using mutations in genomes. The aim of this study was to improve the prediction of the ANRS gold standard in predicting HIV drug resistance. A genome sequence and HIV drug resistance measures were obtained from the Stanford HIV database (http://hivdb.stanford.edu/). Feature selection was used to determine the most important mutations associated with resistance prediction. These mutations were added to the ANRS rules, and the difference in the prediction ability was measured. This study uncovered important mutations that were not associated with the original ANRS rules. On average, the ANRS algorithm was improved by 79% ± 6.6%. The positive predictive value improved by 28%, and the negative predicative value improved by 10%. The study shows that there is a significant improvement in the prediction ability of ANRS gold standard.
Hammarstrom, Jane M.; Johnson, Adam N.; Seal, Robert R.; Meier, Allen L.; Briggs, Paul L.; Piatak, Nadine M.
2006-01-01
The Virginia gold-pyrite belt, part of the central Virginia volcanic-plutonic belt, hosts numerous abandoned metal mines. The belt extends from about 50 km south of Washington, D.C., for approximately 175 km to the southwest into central Virginia. The rocks that comprise the belt include metamorphosed volcanic and clastic (noncarbonate) sedimentary rocks that were originally deposited during the Ordovician). Deposits that were mined can be classified into three broad categories: 1. volcanic-associated massive sulfide deposits, 2. low-sulfide quartz-gold vein deposits, 3. gold placer deposits, which result from weathering of the vein deposits The massive sulfide deposits were historically mined for iron and pyrite (sulfur), zinc, lead, and copper but also yielded byproduct gold and silver. The most intensely mineralized and mined section of the belt is southwest of Fredericksburg, in the Mineral district of Louisa and Spotsylvania counties. The Valzinco Piatak lead-zinc mine and the Mitchell gold prospect are abandoned sites in Spotsylvania County. As a result of environmental impacts associated with historic mining, both sites were prioritized for reclamation under the Virginia Orphaned Land Program administered by the Virginia Department of Mines, Minerals, and Energy (VDMME). This report summarizes geochemical data for all solid sample media, along with mineralogical data, and results of weathering experiments on Valzinco tailings and field experiments on sediment accumulation in Knights Branch. These data provide a framework for evaluating water-rock interactionsand geoenvironmental signatures of long-abandoned mines developed in massive sulfide deposits and low-sulfide gold-quartz vein deposits in the humid temperate ecosystem domain in the eastern United States.
Mocan, Lucian; Ilie, Ioana; Matea, Cristian; Tabaran, Flaviu; Kalman, Ersjebet; Iancu, Cornel; Mocan, Teodora
2014-01-01
Systemic infections caused by methicillin-resistant Staphylococcus aureus (MRSA) and other bacteria are responsible for millions of deaths worldwide, and much of this mortality is due to the rise of antibiotic-resistant organisms as a result of natural selection. Gold nanoparticles synthesized using the standard wet chemical procedure were photoexcited using an 808 nm 2 W laser diode and further administered to MRSA bacteria. Flow cytometry, transmission electron microscopy, contrast phase microscopy, and fluorescence microscopy combined with immunochemical staining were used to examine the interaction of the photoexcited gold nano-particles with MRSA bacteria. We show here that phonon–phonon interactions following laser photoexcitation of gold nanoparticles exhibit increased MRSA necrotic rates at low concentrations and short incubation times compared with MRSA treated with gold nanoparticles alone. These unique data may represent a step forward in the study of bactericidal effects of various nanomaterials, with applications in biology and medicine. PMID:24711697
2001-06-01
important issues need to be understood. Caloric Irrigation: Irrigation of both ears with water of 30 and 44 degree Celsius is the standard Anamnesis ... anamnesis , falls short. In the usual because there are many factors which may clinical situation, a vestibular deficit is suspected if influence the final
There's gold in them thar' databases.
Gillespie, G
2000-11-01
Some health care organizations are using sophisticated data mining applications to unearth hidden truths buried in their online clinical and financial information. But the lack of a standard clinical vocabulary and standard work processes is an obstacle CIOs must blast through to reach their treasure.
NASA Astrophysics Data System (ADS)
Huang, Xiaohua; Kang, Bin; Qian, Wei; Mackey, Megan A.; Chen, Po C.; Oyelere, Adegboyega K.; El-Sayed, Ivan H.; El-Sayed, Mostafa A.
2010-09-01
We conduct a comparative study on the efficiency and cell death pathways of continuous wave (cw) and nanosecond pulsed laser photothermal cancer therapy using gold nanospheres delivered to either the cytoplasm or nucleus of cancer cells. Cytoplasm localization is achieved using arginine-glycine-aspartate peptide modified gold nanospheres, which target integrin receptors on the cell surface and are subsequently internalized by the cells. Nuclear delivery is achieved by conjugating the gold nanospheres with nuclear localization sequence peptides originating from the simian virus. Photothermal experiments show that cell death can be induced with a single pulse of a nanosecond laser more efficiently than with a cw laser. When the cw laser is applied, gold nanospheres localized in the cytoplasm are more effective in inducing cell destruction than gold nanospheres localized at the nucleus. The opposite effect is observed when the nanosecond pulsed laser is used, suggesting that plasmonic field enhancement of the nonlinear absorption processes occurs at high localization of gold nanospheres at the nucleus. Cell death pathways are further investigated via a standard apoptosis kit to show that the cell death mechanisms depend on the type of laser used. While the cw laser induces cell death via apoptosis, the nanosecond pulsed laser leads to cell necrosis. These studies add mechanistic insight to gold nanoparticle-based photothermal therapy of cancer.
The Metadata Coverage Index (MCI): A standardized metric for quantifying database metadata richness.
Liolios, Konstantinos; Schriml, Lynn; Hirschman, Lynette; Pagani, Ioanna; Nosrat, Bahador; Sterk, Peter; White, Owen; Rocca-Serra, Philippe; Sansone, Susanna-Assunta; Taylor, Chris; Kyrpides, Nikos C; Field, Dawn
2012-07-30
Variability in the extent of the descriptions of data ('metadata') held in public repositories forces users to assess the quality of records individually, which rapidly becomes impractical. The scoring of records on the richness of their description provides a simple, objective proxy measure for quality that enables filtering that supports downstream analysis. Pivotally, such descriptions should spur on improvements. Here, we introduce such a measure - the 'Metadata Coverage Index' (MCI): the percentage of available fields actually filled in a record or description. MCI scores can be calculated across a database, for individual records or for their component parts (e.g., fields of interest). There are many potential uses for this simple metric: for example; to filter, rank or search for records; to assess the metadata availability of an ad hoc collection; to determine the frequency with which fields in a particular record type are filled, especially with respect to standards compliance; to assess the utility of specific tools and resources, and of data capture practice more generally; to prioritize records for further curation; to serve as performance metrics of funded projects; or to quantify the value added by curation. Here we demonstrate the utility of MCI scores using metadata from the Genomes Online Database (GOLD), including records compliant with the 'Minimum Information about a Genome Sequence' (MIGS) standard developed by the Genomic Standards Consortium. We discuss challenges and address the further application of MCI scores; to show improvements in annotation quality over time, to inform the work of standards bodies and repository providers on the usability and popularity of their products, and to assess and credit the work of curators. Such an index provides a step towards putting metadata capture practices and in the future, standards compliance, into a quantitative and objective framework.
Neutron transfer in the C 13 + Au 197 reaction from gold isotope residuals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daub, B. H.; Bleuel, D. L.; Wiedeking, M.
Residual gold nuclei were produced in this paper via neutron transfer at multiple energies using a 130-MeV 13C beam incident on a stacked-foil target consisting of alternating layers of 197Au and 27Al. Production cross sections, over an energy range of 56 to 129 MeV, for seven gold isotopes and two gold isomers were determined through activation analysis. By using the Wilczynski binary transfer model with a modified version of the recoil formula and a standard evaporation model, we were able to reproduce the isotopic production cross sections at high beam energy, with some disagreement at lower beam energies. Finally, thismore » limiting angular momentum model does not predict the transfer of sufficient angular momentum to reproduce the observed isomeric populations.« less
Neutron transfer in the C 13 + Au 197 reaction from gold isotope residuals
Daub, B. H.; Bleuel, D. L.; Wiedeking, M.; ...
2017-08-01
Residual gold nuclei were produced in this paper via neutron transfer at multiple energies using a 130-MeV 13C beam incident on a stacked-foil target consisting of alternating layers of 197Au and 27Al. Production cross sections, over an energy range of 56 to 129 MeV, for seven gold isotopes and two gold isomers were determined through activation analysis. By using the Wilczynski binary transfer model with a modified version of the recoil formula and a standard evaporation model, we were able to reproduce the isotopic production cross sections at high beam energy, with some disagreement at lower beam energies. Finally, thismore » limiting angular momentum model does not predict the transfer of sufficient angular momentum to reproduce the observed isomeric populations.« less
ERIC Educational Resources Information Center
Cho, Taejun; Korte, Russell
2014-01-01
The main purpose of the current study is to validate the framework of knowledge management (KM) capabilities created by Gold ("Towards a theory of organizational knowledge management capabilities." Doctoral dissertation, University of North Carolina, Chapel Hill) 2001) in a study of South Korean companies. However, the original framework…
Khmaj, Mofida R; Khmaj, Abdulfatah B; Brantley, William A; Johnston, William M; Dasgupta, Tridib
2014-11-01
New noble alloys for metal ceramic restorations introduced by manufacturers are generally lower-cost alternatives to traditional higher-gold alloys. Information about the metal-to-ceramic bond strength for these alloys, which is needed for rational clinical selection, is often lacking. The purpose of this study was to evaluate the bond strength of 4 recently introduced noble alloys by using 2 techniques for porcelain application. Aquarius Hard (high-gold: 86.1 gold, 8.5 platinum, 2.6 palladium, 1.4 indium; values in wt. %), Evolution Lite (reduced-gold: 40.3 gold, 39.3 palladium, 9.3 indium, 9.2 silver, 1.8 gallium), Callisto 75 Pd (palladium-silver containing gold: 75.2 palladium, 7.1 silver, 2.5 gold, 9.3 tin, 1.0 indium), and Aries, (conventional palladium-silver: 63.7 palladium, 26.0 silver, 7.0 tin, 1.8 gallium, 1.5 indium) were selected for bonding to leucite-containing veneering porcelains. Ten metal ceramic specimens that met dimensional requirements for International Organization for Standardization (ISO) Standard 9693 were prepared for each alloy by using conventional porcelain layering and press-on-metal methods. The 3-point bending test in ISO Standard 9693 was used to determine bond strength. Values were compared with 2-way ANOVA (maximum likelihood analysis, SAS Mixed Procedure) and the Tukey test (α=.05). Means (standard deviations) for bond strength with conventional porcelain layering were as follows: Aquarius Hard (50.7 ±5.5 MPa), Evolution Lite (40.2 ±3.3 MPa), Callisto 75 Pd (37.2 ±3.9 MPa), and Aries (34.0 ±4.9 MPa). For the press-on-metal technique, bond strength results were as follows: Aquarius Hard (33.7 ±11.5 MPa), Evolution Lite (34.9 ±4.5 MPa), Callisto 75 Pd (37.2 ±11.9 MPa), and Aries (30.7 ±10.8 MPa). From statistical analyses, the following 3 significant differences were found for metal-to-ceramic bond strength: the bond strength for Aquarius Hard was significantly higher for conventional porcelain layers compared with the press-on-metal technique; the bond strength for Aquarius Hard with conventional porcelain layers was significantly higher than the bond strengths for the other 3 alloys with conventional porcelain layers; and the bond strength for Aquarius Hard with conventional porcelain layers was significantly higher than the bond strength for Callisto 75 Pd with conventional porcelain layers and the other 3 alloys with the press-on-metal technique. For both conventional layering and press-on-metal techniques, all 4 noble alloys had a mean metal-to-ceramic bond strength that substantially exceeded the 25 MPa minimum in the ISO Standard 9693. The results for Aries support the manufacturer's recommendation not to use the press-on-metal technique for alloys that contain more than 10% silver. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Dilthey, Alexander T; Gourraud, Pierre-Antoine; Mentzer, Alexander J; Cereb, Nezih; Iqbal, Zamin; McVean, Gil
2016-10-01
Genetic variation at the Human Leucocyte Antigen (HLA) genes is associated with many autoimmune and infectious disease phenotypes, is an important element of the immunological distinction between self and non-self, and shapes immune epitope repertoires. Determining the allelic state of the HLA genes (HLA typing) as a by-product of standard whole-genome sequencing data would therefore be highly desirable and enable the immunogenetic characterization of samples in currently ongoing population sequencing projects. Extensive hyperpolymorphism and sequence similarity between the HLA genes, however, pose problems for accurate read mapping and make HLA type inference from whole-genome sequencing data a challenging problem. We describe how to address these challenges in a Population Reference Graph (PRG) framework. First, we construct a PRG for 46 (mostly HLA) genes and pseudogenes, their genomic context and their characterized sequence variants, integrating a database of over 10,000 known allele sequences. Second, we present a sequence-to-PRG paired-end read mapping algorithm that enables accurate read mapping for the HLA genes. Third, we infer the most likely pair of underlying alleles at G group resolution from the IMGT/HLA database at each locus, employing a simple likelihood framework. We show that HLA*PRG, our algorithm, outperforms existing methods by a wide margin. We evaluate HLA*PRG on six classical class I and class II HLA genes (HLA-A, -B, -C, -DQA1, -DQB1, -DRB1) and on a set of 14 samples (3 samples with 2 x 100bp, 11 samples with 2 x 250bp Illumina HiSeq data). Of 158 alleles tested, we correctly infer 157 alleles (99.4%). We also identify and re-type two erroneous alleles in the original validation data. We conclude that HLA*PRG for the first time achieves accuracies comparable to gold-standard reference methods from standard whole-genome sequencing data, though high computational demands (currently ~30-250 CPU hours per sample) remain a significant challenge to practical application.
High-Accuracy HLA Type Inference from Whole-Genome Sequencing Data Using Population Reference Graphs
Dilthey, Alexander T.; Gourraud, Pierre-Antoine; McVean, Gil
2016-01-01
Genetic variation at the Human Leucocyte Antigen (HLA) genes is associated with many autoimmune and infectious disease phenotypes, is an important element of the immunological distinction between self and non-self, and shapes immune epitope repertoires. Determining the allelic state of the HLA genes (HLA typing) as a by-product of standard whole-genome sequencing data would therefore be highly desirable and enable the immunogenetic characterization of samples in currently ongoing population sequencing projects. Extensive hyperpolymorphism and sequence similarity between the HLA genes, however, pose problems for accurate read mapping and make HLA type inference from whole-genome sequencing data a challenging problem. We describe how to address these challenges in a Population Reference Graph (PRG) framework. First, we construct a PRG for 46 (mostly HLA) genes and pseudogenes, their genomic context and their characterized sequence variants, integrating a database of over 10,000 known allele sequences. Second, we present a sequence-to-PRG paired-end read mapping algorithm that enables accurate read mapping for the HLA genes. Third, we infer the most likely pair of underlying alleles at G group resolution from the IMGT/HLA database at each locus, employing a simple likelihood framework. We show that HLA*PRG, our algorithm, outperforms existing methods by a wide margin. We evaluate HLA*PRG on six classical class I and class II HLA genes (HLA-A, -B, -C, -DQA1, -DQB1, -DRB1) and on a set of 14 samples (3 samples with 2 x 100bp, 11 samples with 2 x 250bp Illumina HiSeq data). Of 158 alleles tested, we correctly infer 157 alleles (99.4%). We also identify and re-type two erroneous alleles in the original validation data. We conclude that HLA*PRG for the first time achieves accuracies comparable to gold-standard reference methods from standard whole-genome sequencing data, though high computational demands (currently ~30–250 CPU hours per sample) remain a significant challenge to practical application. PMID:27792722
Stretching of short monatomic gold chains-some model calculations
NASA Astrophysics Data System (ADS)
Sumali, Priyanka, Verma, Veena; Dharamvir, Keya
2012-06-01
The Mechanical properties of zig-zag monatomic gold chains containing 5 and 7 atoms were studied using the Siesta Code (SC), which works within the framework of DFT formalism and Gupta Potential (GP), which is an effective atom-atom potential. The zig-zag chains were stretched by keeping the end atoms fixed while rest of the atoms were relaxed till minimum energy is obtained. Energy, Force and Young's Modulus found using GP and SC were plotted as functions of total length. It is found that the breaking force in case of GP is of order of 1.6nN while for SIESTA is of the order of 2.9nN for both the chains.
Tanev, Stoyan; Sun, Wenbo; Pond, James; Tuchin, Valery V.; Zharov, Vladimir P.
2010-01-01
The formulation of the Finite-Difference Time-Domain (FDTD) approach is presented in the framework of its potential applications to in vivo flow cytometry based on light scattering. The consideration is focused on comparison of light scattering by a single biological cell alone in controlled refractive index matching conditions and by cells labeled by gold nanoparticles. The optical schematics including phase contrast (OPCM) microscopy as a prospective modality for in vivo flow cytometry is also analyzed. The validation of the FDTD approach for the simulation of flow cytometry may open a new avenue in the development of advanced cytometric techniques based on scattering effects from nanoscale targets. PMID:19670359
Bellavance, Gabriel; Barriault, Louis
2014-06-23
The remarkable biological activities of polyprenylated polycyclic acylphloroglucinols (PPAPs) combined with their highly decorated bicyclo[3.3.1]nonane-2,4,9-trione frameworks have inspired synthetic organic chemists over the last decade. The concise total syntheses of four natural products PPAPs; hyperforin and papuaforins A-C, and the formal synthesis of nemorosone are reported. Key to the realization of this strategy is the short and scalable synthesis of densely substituted PPAP scaffolds through a gold(I)-catalyzed 6-endo-dig carbocyclization of cyclic enol ethers for late-stage functionalization. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Batra, U; Parikh, PM; Prabhash, K; Tongaonkar, HB; Chibber, P; Dabkara, D; Deshmukh, C; Ghadyalpatil, N; Hingmire, S; Joshi, A; Raghunath, SK; Rajappa, S; Rajendranath, R; Rawal, SK; Singh, Manisha; Singh, R; Somashekhar, SP; Sood, R
2016-01-01
The Oncology Gold Standard (OGS) Expert Group on renal cell carcinoma (RCC) developed the consensus statement to provide community oncologists practical guidelines on the management of advanced clear cell (cc) RCC using published evidence, practical experience of experts in real life management, and results of a nationwide survey involving 144 health-care professionals. Six broad question categories containing 33 unique questions cover major situations in the routine management of RCC. This document serves as a ready guide for the standard of care to optimize outcome. The table of “Take Home Messages” at the end is a convenient tool for busy practitioners. PMID:28032079
PyGOLD: a python based API for docking based virtual screening workflow generation.
Patel, Hitesh; Brinkjost, Tobias; Koch, Oliver
2017-08-15
Molecular docking is one of the successful approaches in structure based discovery and development of bioactive molecules in chemical biology and medicinal chemistry. Due to the huge amount of computational time that is still required, docking is often the last step in a virtual screening approach. Such screenings are set as workflows spanned over many steps, each aiming at different filtering task. These workflows can be automatized in large parts using python based toolkits except for docking using the docking software GOLD. However, within an automated virtual screening workflow it is not feasible to use the GUI in between every step to change the GOLD configuration file. Thus, a python module called PyGOLD was developed, to parse, edit and write the GOLD configuration file and to automate docking based virtual screening workflows. The latest version of PyGOLD, its documentation and example scripts are available at: http://www.ccb.tu-dortmund.de/koch or http://www.agkoch.de. PyGOLD is implemented in Python and can be imported as a standard python module without any further dependencies. oliver.koch@agkoch.de, oliver.koch@tu-dortmund.de. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Multi-dimensional modeling of atmospheric copper-sulfidation corrosion on non-planar substrates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Ken Shuang
2004-11-01
This report documents the author's efforts in the deterministic modeling of copper-sulfidation corrosion on non-planar substrates such as diodes and electrical connectors. A new framework based on Goma was developed for multi-dimensional modeling of atmospheric copper-sulfidation corrosion on non-planar substrates. In this framework, the moving sulfidation front is explicitly tracked by treating the finite-element mesh as a pseudo solid with an arbitrary Lagrangian-Eulerian formulation and repeatedly performing re-meshing using CUBIT and re-mapping using MAPVAR. Three one-dimensional studies were performed for verifying the framework in asymptotic regimes. Limited model validation was also carried out by comparing computed copper-sulfide thickness with experimentalmore » data. The framework was first demonstrated in modeling one-dimensional copper sulfidation with charge separation. It was found that both the thickness of the space-charge layers and the electrical potential at the sulfidation surface decrease rapidly as the Cu{sub 2}S layer thickens initially but eventually reach equilibrium values as Cu{sub 2}S layer becomes sufficiently thick; it was also found that electroneutrality is a reasonable approximation and that the electro-migration flux may be estimated by using the equilibrium potential difference between the sulfidation and annihilation surfaces when the Cu{sub 2}S layer is sufficiently thick. The framework was then employed to model copper sulfidation in the solid-state-diffusion controlled regime (i.e. stage II sulfidation) on a prototypical diode until a continuous Cu{sub 2}S film was formed on the diode surface. The framework was also applied to model copper sulfidation on an intermittent electrical contact between a gold-plated copper pin and gold-plated copper pad; the presence of Cu{sub 2}S was found to raise the effective electrical resistance drastically. Lastly, future research needs in modeling atmospheric copper sulfidation are discussed.« less
RRegrs: an R package for computer-aided model selection with multiple regression models.
Tsiliki, Georgia; Munteanu, Cristian R; Seoane, Jose A; Fernandez-Lozano, Carlos; Sarimveis, Haralambos; Willighagen, Egon L
2015-01-01
Predictive regression models can be created with many different modelling approaches. Choices need to be made for data set splitting, cross-validation methods, specific regression parameters and best model criteria, as they all affect the accuracy and efficiency of the produced predictive models, and therefore, raising model reproducibility and comparison issues. Cheminformatics and bioinformatics are extensively using predictive modelling and exhibit a need for standardization of these methodologies in order to assist model selection and speed up the process of predictive model development. A tool accessible to all users, irrespectively of their statistical knowledge, would be valuable if it tests several simple and complex regression models and validation schemes, produce unified reports, and offer the option to be integrated into more extensive studies. Additionally, such methodology should be implemented as a free programming package, in order to be continuously adapted and redistributed by others. We propose an integrated framework for creating multiple regression models, called RRegrs. The tool offers the option of ten simple and complex regression methods combined with repeated 10-fold and leave-one-out cross-validation. Methods include Multiple Linear regression, Generalized Linear Model with Stepwise Feature Selection, Partial Least Squares regression, Lasso regression, and Support Vector Machines Recursive Feature Elimination. The new framework is an automated fully validated procedure which produces standardized reports to quickly oversee the impact of choices in modelling algorithms and assess the model and cross-validation results. The methodology was implemented as an open source R package, available at https://www.github.com/enanomapper/RRegrs, by reusing and extending on the caret package. The universality of the new methodology is demonstrated using five standard data sets from different scientific fields. Its efficiency in cheminformatics and QSAR modelling is shown with three use cases: proteomics data for surface-modified gold nanoparticles, nano-metal oxides descriptor data, and molecular descriptors for acute aquatic toxicity data. The results show that for all data sets RRegrs reports models with equal or better performance for both training and test sets than those reported in the original publications. Its good performance as well as its adaptability in terms of parameter optimization could make RRegrs a popular framework to assist the initial exploration of predictive models, and with that, the design of more comprehensive in silico screening applications.Graphical abstractRRegrs is a computer-aided model selection framework for R multiple regression models; this is a fully validated procedure with application to QSAR modelling.
Smith, David P; Fairweather-Schmidt, A Kate; Harvey, Peter W; Battersby, Malcolm W
2018-03-01
Currently, it is unknown whether treatment outcomes derived from randomized controlled trials (RCTs) of cognitive-behavioural therapy (CBT) for problem gamblers still hold when applied to patients seen in routine practice. Thus, data from an RCT of cognitive therapy versus exposure therapy for problem gambling versus patients of a gambling help service were compared. Assessments of problem gambling severity, psychosocial impairment, and alcohol use were undertaken at baseline and post-treatment and evaluated within a counterfactual framework. Findings showed that the contrast between routine CBT for pokies and horse betting had a significant effect, indicative of a 62% lower gambling urge score if routine CBT recipients had all been horse/track betters opposed to gambling with "pokies." However, the majority of contrasts indicated therapeutic outcomes achieved in routine CBT treatments were of equivalent robustness relative to RCT conditions. The present findings infer routine practice treatment outcomes are as efficacious as those generated in RCT contexts. Copyright © 2017 John Wiley & Sons, Ltd.
Network effects of deep brain stimulation
Alhourani, Ahmad; McDowell, Michael M.; Randazzo, Michael J.; Wozny, Thomas A.; Kondylis, Efstathios D.; Lipski, Witold J.; Beck, Sarah; Karp, Jordan F.; Ghuman, Avniel S.
2015-01-01
The ability to differentially alter specific brain functions via deep brain stimulation (DBS) represents a monumental advance in clinical neuroscience, as well as within medicine as a whole. Despite the efficacy of DBS in the treatment of movement disorders, for which it is often the gold-standard therapy when medical management becomes inadequate, the mechanisms through which DBS in various brain targets produces therapeutic effects is still not well understood. This limited knowledge is a barrier to improving efficacy and reducing side effects in clinical brain stimulation. A field of study related to assessing the network effects of DBS is gradually emerging that promises to reveal aspects of the underlying pathophysiology of various brain disorders and their response to DBS that will be critical to advancing the field. This review summarizes the nascent literature related to network effects of DBS measured by cerebral blood flow and metabolic imaging, functional imaging, and electrophysiology (scalp and intracranial electroencephalography and magnetoencephalography) in order to establish a framework for future studies. PMID:26269552
Bayesian multivariate hierarchical transformation models for ROC analysis.
O'Malley, A James; Zou, Kelly H
2006-02-15
A Bayesian multivariate hierarchical transformation model (BMHTM) is developed for receiver operating characteristic (ROC) curve analysis based on clustered continuous diagnostic outcome data with covariates. Two special features of this model are that it incorporates non-linear monotone transformations of the outcomes and that multiple correlated outcomes may be analysed. The mean, variance, and transformation components are all modelled parametrically, enabling a wide range of inferences. The general framework is illustrated by focusing on two problems: (1) analysis of the diagnostic accuracy of a covariate-dependent univariate test outcome requiring a Box-Cox transformation within each cluster to map the test outcomes to a common family of distributions; (2) development of an optimal composite diagnostic test using multivariate clustered outcome data. In the second problem, the composite test is estimated using discriminant function analysis and compared to the test derived from logistic regression analysis where the gold standard is a binary outcome. The proposed methodology is illustrated on prostate cancer biopsy data from a multi-centre clinical trial.
Bayesian multivariate hierarchical transformation models for ROC analysis
O'Malley, A. James; Zou, Kelly H.
2006-01-01
SUMMARY A Bayesian multivariate hierarchical transformation model (BMHTM) is developed for receiver operating characteristic (ROC) curve analysis based on clustered continuous diagnostic outcome data with covariates. Two special features of this model are that it incorporates non-linear monotone transformations of the outcomes and that multiple correlated outcomes may be analysed. The mean, variance, and transformation components are all modelled parametrically, enabling a wide range of inferences. The general framework is illustrated by focusing on two problems: (1) analysis of the diagnostic accuracy of a covariate-dependent univariate test outcome requiring a Box–Cox transformation within each cluster to map the test outcomes to a common family of distributions; (2) development of an optimal composite diagnostic test using multivariate clustered outcome data. In the second problem, the composite test is estimated using discriminant function analysis and compared to the test derived from logistic regression analysis where the gold standard is a binary outcome. The proposed methodology is illustrated on prostate cancer biopsy data from a multi-centre clinical trial. PMID:16217836
Sparse Reconstruction Techniques in MRI: Methods, Applications, and Challenges to Clinical Adoption
Yang, Alice Chieh-Yu; Kretzler, Madison; Sudarski, Sonja; Gulani, Vikas; Seiberlich, Nicole
2016-01-01
The family of sparse reconstruction techniques, including the recently introduced compressed sensing framework, has been extensively explored to reduce scan times in Magnetic Resonance Imaging (MRI). While there are many different methods that fall under the general umbrella of sparse reconstructions, they all rely on the idea that a priori information about the sparsity of MR images can be employed to reconstruct full images from undersampled data. This review describes the basic ideas behind sparse reconstruction techniques, how they could be applied to improve MR imaging, and the open challenges to their general adoption in a clinical setting. The fundamental principles underlying different classes of sparse reconstructions techniques are examined, and the requirements that each make on the undersampled data outlined. Applications that could potentially benefit from the accelerations that sparse reconstructions could provide are described, and clinical studies using sparse reconstructions reviewed. Lastly, technical and clinical challenges to widespread implementation of sparse reconstruction techniques, including optimization, reconstruction times, artifact appearance, and comparison with current gold-standards, are discussed. PMID:27003227
A "client perspective" helps improve services.
1998-01-01
Egypt's Ministry of Health launched a campaign in 1992 to improve client satisfaction with family planning clinic services in the country. In the program, family planning clinic supervisors are being trained to use a checklist of 101 indicators to evaluate services, ranging from the availability of contraceptive commodities to the condition of facilities. Television messages and posters disseminated throughout communities instruct potential clients to look for gold stars on the doors of family planning clinics across the country, indicators of a clinic which meets quality service standards. This program is currently used by almost 4000 clinics nationwide. Family planning services worldwide have long focused upon increasing levels of contraceptive use. More recently, however, they are also focusing upon the quality of services provided. Frameworks for improving services tend to emphasize better ways to interact with clients, and often address how to approach specific management concerns, such as maintaining adequate contraceptive supplies. Client interaction, management concerns, and how quality makes a difference are discussed.
Perrier, Aurélie; Maurel, François; Aubard, Jean
2007-10-04
In the course of developing electronic devices on a molecular scale, dithienylethenes photochromic molecules constitute promising candidates for optoelectronic applications such as memories and switches. There is thus a great interest to understand and control the switching behavior of photochromic compounds deposited on metallic surfaces or nanoparticles. Within the framework of the density functional theory, we studied the effect of small gold clusters (Au3 and Au9) on the electronic structure and absorption spectrum of a model dithienylethene molecule. The molecular orbital interactions between the photochromic molecule and the gold cluster made it possible to rationalize some experimental findings (Dulic, D.; van der Molen, S. J.; Kudernac, T.; Jonkman, H. T.; de Jong, J. J. D.; Bowden, T. N.; van Esch, J.; Feringa, B. L.; van Wees, B. J. Phys. Rev. Lett. 2003, 91, 207402). For the closed-ring isomer, grafting a photochromic molecule on a small gold cluster does not change the characteristics of the electronic transition involved in the ring-opening reaction. On the opposite, the absorption spectrum of the photochromic open-ring isomer is strongly modified by the inclusion of the metallic cluster. In agreement with experimental results, our study thus showed that the cycloreversion reaction which involves the closed-ring isomer should be still possible, whereas the ring-closure reaction which involves the open-ring isomer should be inhibited. Connecting a dithienylethene molecule to a small gold cluster hence provides a qualitative comprehension of the photochromic activities of dithienylethenes connected to a gold surface.
Rieger, Stefan B.; Pfau, Jennifer; Stieglitz, Thomas; Asplund, Maria; Ordonez, Juan S.
2016-01-01
There has been substantial progress over the last decade towards miniaturizing implantable microelectrodes for use in Active Implantable Medical Devices (AIMD). Compared to the rapid development and complexity of electrode miniaturization, methods to monitor and assess functional integrity and electrical functionality of these electrodes, particularly during long term stimulation, have not progressed to the same extent. Evaluation methods that form the gold standard, such as stimulus pulse testing, cyclic voltammetry and electrochemical impedance spectroscopy, are either still bound to laboratory infrastructure (impractical for long term in vivo experiments) or deliver no comprehensive insight into the material’s behaviour. As there is a lack of cost effective and practical predictive measures to understand long term electrode behaviour in vivo, material investigations need to be performed after explantation of the electrodes. We propose the analysis of the electrode and its environment in situ, to better understand and correlate the effects leading to electrode failure. The derived knowledge shall eventually lead to improved electrode designs, increased electrode functionality and safety in clinical applications. In this paper, the concept, design and prototyping of a sensor framework used to analyse the electrode’s behaviour and to monitor diverse electrode failure mechanisms, even during stimulation pulses, is presented. We focused on the electronic circuitry and data acquisition techniques required for a conceptual multi-sensor system. Functionality of single modules and a prototype framework have been demonstrated, but further work is needed to convert the prototype system into an implantable device. In vitro studies will be conducted first to verify sensor performance and reliability. PMID:28042815
de Jong, Rianne; Lutkenhaus, Lotte; van Wieringen, Niek; Visser, Jorrit; Wiersma, Jan; Crama, Koen; Geijsen, Debby; Bel, Arjan
2016-08-01
In radiotherapy for rectum cancer, the target volume is highly deformable. An adaptive plan selection strategy can mitigate the effect of these variations. The purpose of this study was to evaluate the feasibility of an adaptive strategy by assessing the interobserver variation in CBCT-based plan selection. Eleven patients with rectum cancer, treated with a non-adaptive strategy, were selected. Five CBCT scans were available per patient. To simulate the plan selection strategy, per patient three PTVs were created by varying the anterior upper mesorectum margin. For each CBCT scan, twenty observers selected the smallest PTV that encompassed the target volume. After this initial baseline measurement, the gold standard was determined during a consensus meeting, followed by a second measurement one month later. Differences between both measurements were assessed using the Wilcoxon signed-rank test. In the baseline measurement, the concordance with the gold standard was 69% (range: 60-82%), which improved to 75% (range: 60-87%) in the second measurement (p=0.01). For the second measurement, 10% of plan selections were smaller than the gold standard. With a plan selection consistency between observers of 75%, a plan selection strategy for rectum cancer patients is feasible. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Al-Awadhi, E A; Wolstencroft, S J; Blake, M
2006-01-01
To evaluate the service purchased from contracted orthodontic laboratories used by HSE (SWA) regional orthodontic unit, St. James's Hospital, Dublin and identify deficiencies in the current service. A data collection questionnaire was designed and distributed to the departmental orthodontists for a period of three months (October-December 2004). Gold standards, drawn up based on the authors' ideal requirements and published guidelines, were supplied to grade the work returned. During the study period 363 items of laboratory work were requested. 20% of the laboratory work arrived late and most of the delayed work was delayed for more than 24 hours. Most laboratory delays occurred with functional appliances, retainers and study models. Prior to fit, 20% of the appliances required adjustments for more than 30 seconds. 65% of laboratory work returned to the department met all of the gold standards. 10% of appliances were considered unsatisfactory. Functional appliances were most often ill fitting accounting for almost half of the unsatisfactory laboratory work. The majority of the laboratory work returned to the department met our gold standards and arrived on time. Forty six percent of the appliances required adjustments. Functional appliances required the most adjustments; one in five of all functional appliances ordered were considered unsatisfactory.
Jokinen, Jukka; Snellman, Marja; Palmu, Arto A; Saukkoriipi, Annika; Verlant, Vincent; Pascal, Thierry; Devaster, Jeanne-Marie; Hausdorff, William P; Kilpi, Terhi M
2018-06-01
Clinical assessments of vaccines to prevent pneumococcal community-acquired pneumonia (CAP) require sensitive and specific case definitions, but there is no gold standard diagnostic test. To develop a new case definition suitable for vaccine efficacy studies, we applied latent class analysis (LCA) to the results from 7 diagnostic tests for pneumococcal etiology on clinical specimens from 323 elderly persons with radiologically confirmed pneumonia enrolled in the Finnish Community-Acquired Pneumonia Epidemiology study during 2005-2007. Compared with the conventional use of LCA, which is mainly to determine sensitivities and specificities of different tests, we instead used LCA as an appropriate instrument to predict the probability of pneumococcal etiology for each CAP case based on individual test profiles, and we used the predictions to minimize the sample size that would be needed for a vaccine efficacy trial. When compared with the conventional laboratory criteria of encapsulated pneumococci in culture, in blood culture or high-quality sputum culture, or urine antigen positivity, our optimized case definition for pneumococcal CAP resulted in a trial sample size that was almost 20,000 subjects smaller. We believe that the novel application of LCA detailed here to determine a case definition for pneumococcal CAP could also be similarly applied to other diseases without a gold standard.
Development of a mobile application for oral cancer screening.
Gomes, Mayra Sousa; Bonan, Paulo Rogério Ferreti; Ferreira, Vitor Yuri Nicolau; de Lucena Pereira, Laudenice; Correia, Ricardo João Cruz; da Silva Teixeira, Hélder Bruno; Pereira, Daniel Cláudio; Bonan, Paulo
2017-01-01
To develop a mobile application (app) for oral cancer screening. The app was developed using Android system version 4.4.2, with JAVA language. Information concerning sociodemographic data and risk factors for oral cancer development, e.g., tobacco and alcohol use, sun exposure and other contributing factors, such as unprotected oral sex, oral pain and denture use, were included. We surveyed a population at high risk for oral cancer development and then evaluated the sensitivity/specificity/accuracy and predictive values of clinical oral diagnosis between two blinded trained examiners, who used movies and data from the app, and in loco oral examination as gold-standard. A total of 55 individuals at high risk for oral cancer development were surveyed. Of these, 31% presented homogeneous/heterogeneous white lesions with potential of malignancy. The clinical diagnoses performed by the two examiners using videos were found to have sensitivity of 82%-100% (average 91%), specificity of 81%-100% (average 90.5%), and accuracy of 87.27%-95.54% (average 90.90%), as compared with the gold-standard. The Kappa agreement value between the gold-standard and the examiner with the best agreement was 0.597. Mobile apps including videos and data collection interfaces could be an interesting alternative in oral cancer research development.
Acar, Buket; Kamburoğlu, Kıvanç; Tatar, İlkan; Arıkan, Volkan; Çelik, Hakan Hamdi; Yüksel, Selcen; Özen, Tuncer
2015-12-01
This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.
Angus, Derek C.; Seymour, Christopher W.; Coopersmith, Craig M.; Deutschman, Clifford; Klompas, Michael; Levy, Mitchell M.; Martin, Greg S.; Osborn, Tiffany M.; Rhee, Chanu; Watson, R. Scott
2016-01-01
Although sepsis was described more than 2,000 years ago, and clinicians still struggle to define it, there is no “gold standard,” and multiple competing approaches and terms exist. Challenges include the ever-changing knowledge base that informs our understanding of sepsis, competing views on which aspects of any potential definition are most important, and the tendency of most potential criteria to be distributed in at-risk populations in such a way as to hinder separation into discrete sets of patients. We propose that the development and evaluation of any definition or diagnostic criteria should follow four steps: 1) define the epistemologic underpinning, 2) agree on all relevant terms used to frame the exercise, 3) state the intended purpose for any proposed set of criteria, and 4) adopt a scientific approach to inform on their usefulness with regard to the intended purpose. Usefulness can be measured across six domains: 1) reliability (stability of criteria during retesting, between raters, over time, and across settings), 2) content validity (similar to face validity), 3) construct validity (whether criteria measure what they purport to measure), 4) criterion validity (how new criteria fare compared to standards), 5) measurement burden (cost, safety, and complexity), and 6) timeliness (whether criteria are available concurrent with care decisions). The relative importance of these domains of usefulness depends on the intended purpose, of which there are four broad categories: 1) clinical care, 2) research, 3) surveillance, and 4) quality improvement and audit. This proposed methodologic framework is intended to aid understanding of the strengths and weaknesses of different approaches, provide a mechanism for explaining differences in epidemiologic estimates generated by different approaches, and guide the development of future definitions and diagnostic criteria. PMID:26901559
Sapsford, R J; Lawrance, R A; Dorsch, M F; Das, R; Jackson, B M; Morrell, C; Robinson, M B; Hall, A S
2003-03-01
The National Service Framework (NSF) for Coronary Heart Disease requires annual clinical audit of the care of patients with myocardial infarction, with little guidance on how to achieve these standards and monitor practice. To assess which method of identification of acute myocardial infarction (AMI) cases is most suitable for NSF audit, and to determine the effect of the definition of AMI on the assessment of quality of care. Observational study. Over a 3-month period, 2153 consecutive patients from 20 hospitals across the Yorkshire region, with confirmed AMI, were identified from coronary care registers, biochemistry records and hospital coding systems. The sensitivity and positive predictive value of AMI patient identification using clinical coding, biochemistry and coronary care registers were compared to a 'gold standard' (the combination of all three methods). Of 3685 possible cases of AMI singled out by one or more methods, 2153 patients were identified as having a final diagnosis of AMI. Hospital coding revealed 1668 (77.5%) cases, with a demographic profile similar to that of the total cohort. Secondary preventative measures required for inclusion in NSF were also of broadly similar distribution. The sensitivities and positive predictive values for patient identification were substantially less in the cohorts identified through biochemistry and coronary care unit register. Patients fulfilling WHO criteria (n=1391) had a 30-day mortality of 15.9%, vs. 24.2% for the total cohort. Hospital coding misses a substantial proportion (22.5%) of AMI cases, but without any apparent systematic bias, and thus provides a suitably representative and robust basis for NSF-related audit. Better still would be the routine use of multiple methods of case identification.
Williams, Peter Huw; de Lusignan, Simon
2006-01-01
The Royal College of Physicians (RCP) have produced guidelines for stroke management in primary care; this guidance is taken to be the gold standard for the care of people with stroke. UK general practitioners now have a quality-based contract which includes a Quality and Outcomes Framework (QOF). This consists of financially remunerated 'quality points' for specific disease areas, including stroke. Achievement of these quality points is measured by extracting a limited list of computer codes from practice computer systems. To investigate whether a high stroke quality score is associated with adherence to RCP guidelines. Examination of computer and written medical records of all patients with a diagnosis of stroke. Two general practices, one in southwest London, one in Surrey, with a combined practice population of over 20 000. Both practices had a similar age-sex profile and prevalence of stroke. One practice scored 93.5% (29/31) of the available stroke quality points. The other practice achieved 73.4% (22.75/31), and only did better in one stroke quality target. However, the practice scoring fewer quality points had much better adherence to RCP guidance: 96% of patients were assessed in secondary care compared with 79% (P=0.001); 64% of stroke patients were seen the same day, compared with 44%; 56% received rehabilitation compared with 37%. Higher quality points did not reflect better adherence to RCP guidance. This audit highlights a gap between relatively simplistic measures of quality in the QOF, dependent on the recording of a narrow range of computer codes, and the actual standard of care being delivered. Research is needed to see whether this finding is generalisable and how the Quality and Outcomes Framework might be better aligned with delivering best practice.
Angus, Derek C; Seymour, Christopher W; Coopersmith, Craig M; Deutschman, Clifford S; Klompas, Michael; Levy, Mitchell M; Martin, Gregory S; Osborn, Tiffany M; Rhee, Chanu; Watson, R Scott
2016-03-01
Although sepsis was described more than 2,000 years ago, and clinicians still struggle to define it, there is no "gold standard," and multiple competing approaches and terms exist. Challenges include the ever-changing knowledge base that informs our understanding of sepsis, competing views on which aspects of any potential definition are most important, and the tendency of most potential criteria to be distributed in at-risk populations in such a way as to hinder separation into discrete sets of patients. We propose that the development and evaluation of any definition or diagnostic criteria should follow four steps: 1) define the epistemologic underpinning, 2) agree on all relevant terms used to frame the exercise, 3) state the intended purpose for any proposed set of criteria, and 4) adopt a scientific approach to inform on their usefulness with regard to the intended purpose. Usefulness can be measured across six domains: 1) reliability (stability of criteria during retesting, between raters, over time, and across settings), 2) content validity (similar to face validity), 3) construct validity (whether criteria measure what they purport to measure), 4) criterion validity (how new criteria fare compared to standards), 5) measurement burden (cost, safety, and complexity), and 6) timeliness (whether criteria are available concurrent with care decisions). The relative importance of these domains of usefulness depends on the intended purpose, of which there are four broad categories: 1) clinical care, 2) research, 3) surveillance, and 4) quality improvement and audit. This proposed methodologic framework is intended to aid understanding of the strengths and weaknesses of different approaches, provide a mechanism for explaining differences in epidemiologic estimates generated by different approaches, and guide the development of future definitions and diagnostic criteria.
NASA Astrophysics Data System (ADS)
Munbodh, R.; Moseley, D. J.
2014-03-01
We report results of an intensity-based 2D-3D rigid registration framework for patient positioning and monitoring during brain radiotherapy. We evaluated two intensity-based similarity measures, the Pearson Correlation Coefficient (ICC) and Maximum Likelihood with Gaussian noise (MLG) derived from the statistics of transmission images. A useful image frequency band was identified from the bone-to-no-bone ratio. Validation was performed on gold-standard data consisting of 3D kV CBCT scans and 2D kV radiographs of an anthropomorphic head phantom acquired at 23 different poses with parameter variations along six degrees of freedom. At each pose, a single limited field of view kV radiograph was registered to the reference CBCT. The ground truth was determined from markers affixed to the phantom and visible in the CBCT images. The mean (and standard deviation) of the absolute errors in recovering each of the six transformation parameters along the x, y and z axes for ICC were varphix: 0.08(0.04)°, varphiy: 0.10(0.09)°, varphiz: 0.03(0.03)°, tx: 0.13(0.11) mm, ty: 0.08(0.06) mm and tz: 0.44(0.23) mm. For MLG, the corresponding results were varphix: 0.10(0.04)°, varphiy: 0.10(0.09)°, varphiz: 0.05(0.07)°, tx: 0.11(0.13) mm, ty: 0.05(0.05) mm and tz: 0.44(0.31) mm. It is feasible to accurately estimate all six transformation parameters from a 3D CBCT of the head and a single 2D kV radiograph within an intensity-based registration framework that incorporates the physics of transmission images.
Harvesting multiple electron-hole pairs generated through plasmonic excitation of Au nanoparticles.
Kim, Youngsoo; Smith, Jeremy G; Jain, Prashant K
2018-05-07
Multi-electron redox reactions, although central to artificial photosynthesis, are kinetically sluggish. Amidst the search for synthetic catalysts for such processes, plasmonic nanoparticles have been found to catalyse multi-electron reduction of CO 2 under visible light. This example motivates the need for a general, insight-driven framework for plasmonic catalysis of such multi-electron chemistry. Here, we elucidate the principles underlying the extraction of multiple redox equivalents from a plasmonic photocatalyst. We measure the kinetics of electron harvesting from a gold nanoparticle photocatalyst as a function of photon flux. Our measurements, supported by theoretical modelling, reveal a regime where two-electron transfer from the excited gold nanoparticle becomes prevalent. Multiple electron harvesting becomes possible under continuous-wave, visible-light excitation of moderate intensity due to strong interband transitions in gold and electron-hole separation accomplished using a hole scavenger. These insights will help expand the utility of plasmonic photocatalysis beyond CO 2 reduction to other challenging multi-electron, multi-proton transformations such as N 2 fixation.
Martín-Santos, Cecilia; Michelucci, Elena; Marzo, Tiziano; Messori, Luigi; Szumlas, Piotr; Bednarski, Patrick J; Mas-Ballesté, Rubén; Navarro-Ranninger, Carmen; Cabrera, Silvia; Alemán, José
2015-12-01
In this article, we report on the synthesis and the chemical and biological characterization of novel gold(III) complexes based on hydroxyl- or amino-quinoline ligands that are evaluated as prospective anticancer agents. To gain further insight into their reactivity and possible mode of action, their interactions with model proteins and standard nucleic acid molecules were investigated. Copyright © 2015 Elsevier Inc. All rights reserved.
Sepsis Definitions: The Search for Gold and What CMS Got Wrong.
Kalantari, Annahieta; Mallemat, Haney; Weingart, Scott D
2017-08-01
On October 1, 2015, the United States Centers for Medicare and Medicaid Services (CMS) issued a core measure addressing the care of septic patients. These core measures are controversial among healthcare providers. This article will address that there is no gold standard definition for sepsis, severe sepsis or septic shock and the CMS-assigned definitions for severe sepsis and septic shock are premature and inconsistent with evidence-based definitions.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-10
... Formaldehyde; Third-Party Certification Framework for the Formaldehyde Standards for Composite Wood Products; Formaldehyde Emissions Standards for Composite Wood Products; Proposed Rules #0;#0;Federal Register / Vol. 78... Certification Framework for the Formaldehyde Standards for Composite Wood Products AGENCY: Environmental...
Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M.; Nelson, Noele P.; Mawudeku, Abla; Madoff, Lawrence C.; Linge, Jens P.; Collier, Nigel; Brownstein, John S.; Astagneau, Pascal
2014-01-01
Background Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Method and Findings Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems’ performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p = 0001) whereas other indicators were similar (C-DR: p = 020; C-Se, p = 013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Conclusion Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p = 00001) after adjustment for other variables. Overall, the use of moderation, sources, languages, regions of occurrence, and types of cases were found to influence system performance. PMID:24599062
Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M; Nelson, Noele P; Mawudeku, Abla; Madoff, Lawrence C; Linge, Jens P; Collier, Nigel; Brownstein, John S; Astagneau, Pascal
2014-01-01
Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems' performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p=0001) whereas other indicators were similar (C-DR: p=020; C-Se, p=013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p=00001) after adjustment for other variables. Overall, the use of moderation, sources, languages, regions of occurrence, and types of cases were found to influence system performance.
Accurate GM atrophy quantification in MS using lesion-filling with co-registered 2D lesion masks☆
Popescu, V.; Ran, N.C.G.; Barkhof, F.; Chard, D.T.; Wheeler-Kingshott, C.A.; Vrenken, H.
2014-01-01
Background In multiple sclerosis (MS), brain atrophy quantification is affected by white matter lesions. LEAP and FSL-lesion_filling, replace lesion voxels with white matter intensities; however, they require precise lesion identification on 3DT1-images. Aim To determine whether 2DT2 lesion masks co-registered to 3DT1 images, yield grey and white matter volumes comparable to precise lesion masks. Methods 2DT2 lesion masks were linearly co-registered to 20 3DT1-images of MS patients, with nearest-neighbor (NNI), and tri-linear interpolation. As gold-standard, lesion masks were manually outlined on 3DT1-images. LEAP and FSL-lesion_filling were applied with each lesion mask. Grey (GM) and white matter (WM) volumes were quantified with FSL-FAST, and deep gray matter (DGM) volumes using FSL-FIRST. Volumes were compared between lesion mask types using paired Wilcoxon tests. Results Lesion-filling with gold-standard lesion masks compared to native images reduced GM overestimation by 1.93 mL (p < .001) for LEAP, and 1.21 mL (p = .002) for FSL-lesion_filling. Similar effects were achieved with NNI lesion masks from 2DT2. Global WM underestimation was not significantly influenced. GM and WM volumes from NNI, did not differ significantly from gold-standard. GM segmentation differed between lesion masks in the lesion area, and also elsewhere. Using the gold-standard, FSL-FAST quantified as GM on average 0.4% of the lesion area with LEAP and 24.5% with FSL-lesion_filling. Lesion-filling did not influence DGM volumes from FSL-FIRST. Discussion These results demonstrate that for global GM volumetry, precise lesion masks on 3DT1 images can be replaced by co-registered 2DT2 lesion masks. This makes lesion-filling a feasible method for GM atrophy measurements in MS. PMID:24567908
Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter
2016-01-01
A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80-0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76-0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94-0.99) for the MC-PCR and 0.99 (95% PCI 0.99-1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997-1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83).
Evaluation of dental therapists undertaking dental examinations in a school setting in Scotland.
O'Keefe, Emma J; McMahon, Alex D; Jones, Colwyn M; Curnow, Morag M; Macpherson, Lorna M D
2016-12-01
To measure agreement between dental therapists and the Scottish gold-standard dentist undertaking National Dental Inspection Programme (NDIP) examinations. A study of interexaminer agreement between 19 dental therapists and the national gold-standard dentist was carried out. Pre-calibration training used the caries diagnostic criteria and examination techniques agreed by the British Association for the Study of Community Dentistry (BASCD). Twenty-three 5-year-old children (Primary 1) and 17 11-year-old children (Primary 7) children were examined. Agreement was assessed using kappa statistics on d 3 mft and D 3 MFT for P1 and P7 children, sensitivity and specificity values, and kappa statistics on d 3 t/D 3 T and ft/FT. Calibration data on P1 and P7 children from 2009-2012 involving dentists as examiners were used for comparison. Economic evaluation was undertaken using a cost minimization analysis approach. The mean kappa score was 0.84 (SD 0.07) ranging from 0.69 to 0.94. All dental therapists scored good or very good agreement with the gold-standard dentist. This compares with historic NDIP calibration data with dentists, against the same gold-standard dentist, where the mean kappa value was 0.68 (SD 0.22) with a range of 0.35-1.00. The mean sensitivity score was 0.98 (SD 0.04) (range 0.88-1.0) and mean specificity score was 0.90 (SD 0.06) (range 0.78-0.96). Health economic analysis estimated that salary costs would be 33.6% lower if dental therapists were substituted for dentists in the year 2013, with an estimated saving of approximately £103 646 per annum on the national budget. We conclude that dental therapists show a high level of interexaminer agreement, and with the appropriate annual training and calibration, they could undertake dental examinations as part of the NDIP programme. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cardiac auscultatory recording database: delivering heart sounds through the Internet.
Tuchinda, C.; Thompson, W. R.
2001-01-01
The clinical skill of cardiac auscultation, while known to be sensitive, specific, and inexpensive in screening for cardiac disease among children, has recently been shown to be deficient among residents in training. This decline in clinical skill is partly due to the difficulty in teaching auscultation. Standardization, depth, and breadth of experience has been difficult to reproduce for students due to time constraints and the impracticality of examining large numbers of patients with cardiac pathology. We have developed a web-based multimedia platform that delivers complete heart sound recordings from over 800 different patients seen at the Johns Hopkins Outpatient Pediatric Cardiology Clinic. The database represents more than twenty significant cardiac lesions as well as normal and innocent murmurs. Each patient record is complete with a gold standard echo for diagnostic confirmation and a gold standard auscultatory assessment provided by a pediatric cardiology attending. PMID:11825279
Improving the fit of implant prosthetics: an in vitro study.
Yannikakis, Stavros; Prombonas, Anthony
2013-01-01
Accurate and passive fit between a prosthesis and its supporting implants has been considered a prerequisite for successful long-term osseointegration. The objective of this in vitro study was to evaluate the strain development during tightening of a five-unit screw-retained superstructure constructed using five different methods. Five-unit screw-retained fixed partial prostheses (n = 25) were fabricated on three implants embedded in an epoxy resin block using five different methods: (1) cobalt-chromium (Co-Cr), plastic cylinders, one-piece cast; (2) Co-Cr, plastic cylinders, framework sectioned, preceramic laser-welding soldering; (3) gold-platinum (Au-Pt), gold cylinders, one-piece cast; (4) Au-Pt, gold cylinders, framework sectioned, preceramic laser-welding soldering; (5) Co-Cr, one-piece cast, and cementation to "passive abutments" (Southern Implants) after final finishing and polishing. Strain gauges (SG) were attached to the fixed partial prosthesis (FPP) and to the resin block to measure the stress created during screw tightening. The combination of Co-Cr alloy and plastic cylinders in a one-piece cast showed such an inadequate fit among the fabricated methods that this group was excluded from the remainder of the experiment. Specimens of Au-Pt cast on gold cylinders in one piece showed higher strain development than the other groups used in this study, with strains ranging from 223.1 to 2,198.1 Μm/m. Sectioning and soldering significantly improved the overall fit. FPPs of Co-Cr in a one-piece cast cemented to "passive abutments" produced the best level of fit, with the least strain development in the prosthesis and the resin block (59 to 204.6 Μm/m). Absolute fit of superstructures on implants is not possible using conventional laboratory procedures. Cementing FPPs onto prefabricated cylinders directly onto the implants significantly reduces strain development compared to the other fabrication methods.
Comparison of Some Secondary Body Composition Algorithms
ERIC Educational Resources Information Center
Sutton, Robert A.; Miller, Carolyn
2006-01-01
Body composition measurements vary greatly in degree of measurement difficulty and accuracy. Hydrostatic weighing, chemical dilution or their equivalents were the accepted "gold" standards for assessing fat mass. Dual Energy X-ray Absorptiometry (DEXA) is fast replacing these techniques as the preferred standard. However, these direct measurement…
Luize, Ana P; Menezes, Ana Maria B; Perez-Padilla, Rogelio; Muiño, Adriana; López, Maria Victorina; Valdivia, Gonzalo; Lisboa, Carmem; Montes de Oca, Maria; Tálamo, Carlos; Celli, Bartolomé; Nascimento, Oliver A; Gazzotti, Mariana R; Jardim, José R
2014-10-30
Spirometry is the gold standard for diagnosing chronic obstructive pulmonary disease (COPD). Although there are a number of different guideline criteria for deciding who should be selected for spirometric screening, to date it is not known which criteria are the best based on sensitivity and specificity. Firstly, to evaluate the proportion of subjects in the PLATINO Study that would be recommended for spirometry testing according to Global initiative for Obstructive Lung Disease (GOLD)-modified, American College of Chest Physicians (ACCP), National Lung Health Education Program (NLHEP), GOLD and American Thoracic Society/European Respiratory Society (ATS/ERS) criteria. Secondly, we aimed to compare the sensitivity, specificity, and positive predictive and negative predictive values, of these five different criteria. Data from the PLATINO study included information on respiratory symptoms, smoking and previous spirometry testing. The GOLD-modified spirometry indication criteria are based on three positive answers out of five questions: the presence of cough, phlegm in the morning, dyspnoea, age over 40 years and smoking status. Data from 5,315 subjects were reviewed. Fewer people had an indication for spirometry (41.3%) according to the GOLD-modified criteria, and more people had an indication for spirometry (80.4%) by the GOLD and ATS/ERS criteria. A low percentage had previously had spirometry performed: GOLD-modified (14.5%); ACCP (13.2%); NLHEP (12.6%); and GOLD and ATS/ERS (12.3%). The GOLD-modified criteria showed the least sensitivity (54.9) and the highest specificity (61.0) for detecting COPD, whereas GOLD and ATS/ERS criteria showed the highest sensitivity (87.9) and the least specificity (20.8). There is a considerable difference in the indication for spirometry according to the five different guideline criteria. The GOLD-modified criteria recruit less people with the greatest sum of sensitivity and specificity.
Luize, Ana P; Menezes, Ana Maria B; Perez-Padilla, Rogelio; Muiño, Adriana; López, Maria Victorina; Valdivia, Gonzalo; Lisboa, Carmem; Montes de Oca, Maria; Tálamo, Carlos; Celli, Bartolomé; Nascimento, Oliver A; Gazzotti, Mariana R; Jardim, José R
2014-01-01
Background: Spirometry is the gold standard for diagnosing chronic obstructive pulmonary disease (COPD). Although there are a number of different guideline criteria for deciding who should be selected for spirometric screening, to date it is not known which criteria are the best based on sensitivity and specificity. Aims: Firstly, to evaluate the proportion of subjects in the PLATINO Study that would be recommended for spirometry testing according to Global initiative for Obstructive Lung Disease (GOLD)-modified, American College of Chest Physicians (ACCP), National Lung Health Education Program (NLHEP), GOLD and American Thoracic Society/European Respiratory Society (ATS/ERS) criteria. Secondly, we aimed to compare the sensitivity, specificity, and positive predictive and negative predictive values, of these five different criteria. Methods: Data from the PLATINO study included information on respiratory symptoms, smoking and previous spirometry testing. The GOLD-modified spirometry indication criteria are based on three positive answers out of five questions: the presence of cough, phlegm in the morning, dyspnoea, age over 40 years and smoking status. Results: Data from 5,315 subjects were reviewed. Fewer people had an indication for spirometry (41.3%) according to the GOLD-modified criteria, and more people had an indication for spirometry (80.4%) by the GOLD and ATS/ERS criteria. A low percentage had previously had spirometry performed: GOLD-modified (14.5%); ACCP (13.2%); NLHEP (12.6%); and GOLD and ATS/ERS (12.3%). The GOLD-modified criteria showed the least sensitivity (54.9) and the highest specificity (61.0) for detecting COPD, whereas GOLD and ATS/ERS criteria showed the highest sensitivity (87.9) and the least specificity (20.8). Conclusion: There is a considerable difference in the indication for spirometry according to the five different guideline criteria. The GOLD-modified criteria recruit less people with the greatest sum of sensitivity and specificity. PMID:25358021
Crisp, Ginny D; Burkhart, Jena Ivey; Esserman, Denise A; Weinberger, Morris; Roth, Mary T
2011-12-01
Medication is one of the most important interventions for improving the health of older adults, yet it has great potential for causing harm. Clinical pharmacists are well positioned to engage in medication assessment and planning. The Individualized Medication Assessment and Planning (iMAP) tool was developed to aid clinical pharmacists in documenting medication-related problems (MRPs) and associated recommendations. The purpose of our study was to assess the reliability and usability of the iMAP tool in classifying MRPs and associated recommendations in older adults in the ambulatory care setting. Three cases, representative of older adults seen in an outpatient setting, were developed. Pilot testing was conducted and a "gold standard" key developed. Eight eligible pharmacists consented to participate in the study. They were instructed to read each case, make an assessment of MRPs, formulate a plan, and document the information using the iMAP tool. Inter-rater reliability was assessed for each case, comparing the pharmacists' identified MRPs and recommendations to the gold standard. Consistency of categorization across reviewers was assessed using the κ statistic or percent agreement. The mean κ across the 8 pharmacists in classifying MRPs compared with the gold standard was 0.74 (range, 0.54-1.00) for case 1 and 0.68 (range, 0.36-1.00) for case 2, indicating substantial agreement. For case 3, percent agreement was 63% (range, 40%-100%). The mean κ across the 8 pharmacists when classifying recommendations compared with the gold standard was 0.87 (range, 0.58-1.00) for case 1 and 0.88 (range, 0.75-1.00) for case 2, indicating almost perfect agreement. For case 3, percent agreement was 68% (range, 40%-100%). Clinical pharmacists found the iMAP tool easy to use. The iMAP tool provides a reliable and standardized approach for clinical pharmacists to use in the ambulatory care setting to classify MRPs and associated recommendations. Future studies will explore the predictive validity of the tool on clinical outcomes such as health care utilization. Copyright © 2011 Elsevier HS Journals, Inc. All rights reserved.
Gold-on-Polymer-Based Sensing Films for Detection of Organic and Inorganic Analytes in the Air
NASA Technical Reports Server (NTRS)
Manatt, Kenneth; Homer, Margie; Ryan, Margaret; Kisor, Adam; Shevade, Abhijit; Jewell, April; Zhou, Hanying
2008-01-01
A document discusses gold-on-polymer as one of the novel sensor types developed for part of the sensor development task. Standard polymer-carbon composite sensors used in the JPL Electronic Nose (ENose) have been modified by evaporating 15 nm of metallic gold on the surface. These sensors have been shown to respond to alcohols, aromatics, ammonia, sulfur dioxide, and elemental mercury in the parts-per-million and parts-per-billion concentration ranges in humidified air. The results have shown good sensitivity of these films operating under mild conditions (operating temperatures 23-28 C and regeneration temperature up to 40 C). This unique sensor combines the diversity of polymer sensors for chemical sensing with their response to a wide variety of analytes with the specificity of a gold sensor that shows strong reaction/binding with selected analyte types, such as mercury or sulfur.
Pagno, Carlos H; Costa, Tania M H; de Menezes, Eliana W; Benvenutti, Edilson V; Hertz, Plinho F; Matte, Carla R; Tosati, Juliano V; Monteiro, Alcilene R; Rios, Alessandro O; Flôres, Simone H
2015-04-15
Active biofilms of quinoa (Chenopodium quinoa, W.) starch were prepared by incorporating gold nanoparticles stabilised by an ionic silsesquioxane that contains the 1,4-diazoniabicyclo[2.2.2]octane chloride group. The biofilms were characterised and their antimicrobial activity was evaluated against Escherichiacoli and Staphylococcusaureus. The presence of gold nanoparticles produces an improvement in the mechanical, optical and morphological properties, maintaining the thermal and barrier properties unchanged when compared to the standard biofilm. The active biofilms exhibited strong antibacterial activity against food-borne pathogens with inhibition percentages of 99% against E. coli and 98% against S. aureus. These quinoa starch biofilms containing gold nanoparticles are very promising to be used as active food packaging for the maintenance of food safety and extension of the shelf life of packaged foods. Copyright © 2014 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The impact of standardizing the originally measured serum total 25-hydroxyvitamin D [25(OH)D] values from Third National Health and Nutrition Examination Survey (NHANES III, 1988-1994) on the association between 25(OH)D and rate of all-cause mortality was evaluated. Values were standardized to gold ...
ERIC Educational Resources Information Center
Burdett, Newman
2015-01-01
This election factsheet highlights the following points: (1) While the GCSE pass rate has increased since its introduction, this doesn't tell us very much about how standards have changed. Evidence from international surveys suggests that education standards have remained stable. Stopping the use of modules and limiting resits is likely to reduce…
Gold leaf: From gilding to the fabrication of disposable, wearable and low-cost electrodes.
Santos, Mauro Sérgio Ferreira; Ameku, Wilson Akira; Gutz, Ivano Gebhardt Rolf; Paixão, Thiago Regis Longo Cesar
2018-03-01
Gold is among the most used materials in electrocatalysis. Despite this, this noble metal is still too expensive to be used in the fabrication of low cost and disposable devices. In the present work, gold-leaf sheets, usually employed in decorative crafts and wedding candies, is introduced as an inexpensive source of gold. Planar-disc and nanoband gold electrodes were simply and easily manufactured by combining gold leaf and polyimide tape. The planar disc electrode exhibited electrochemical behavior similar to that of a commercial gold electrode in 0.2molL -1 H 2 SO 4 ; cyclic voltammetry of a 1mmolL -1 solution of potassium ferricyanide (K 3 [Fe(CN) 6 ]) in 0.2molL -1 KNO 3 , using this novel electrode, displayed an 80mV difference between the oxidation and reduction peak potentials. The electrode also delivers promising prospects for the development of wearable devices. When submitted to severe mechanical deformation, this electrode exhibited neither loss of electrical contact nor significant variation in electrode response, even after fifteen bending and/or folding cycles. The thickness of the gold-leaf sheet facilitates the production of nanoband electrodes with behavior similar to that of ultramicroelectrodes. The electrode surface is easily renewed by cutting a thin slice off its end with a razor blade; this process led to limiting currents that were reproducible, presenting a relative standard deviation (RSD) of 3.8% (n = 5). Copyright © 2017 Elsevier B.V. All rights reserved.
Noninvasive Fetal ECG: the PhysioNet/Computing in Cardiology Challenge 2013.
Silva, Ikaro; Behar, Joachim; Sameni, Reza; Zhu, Tingting; Oster, Julien; Clifford, Gari D; Moody, George B
2013-03-01
The PhysioNet/CinC 2013 Challenge aimed to stimulate rapid development and improvement of software for estimating fetal heart rate (FHR), fetal interbeat intervals (FRR), and fetal QT intervals (FQT), from multichannel recordings made using electrodes placed on the mother's abdomen. For the challenge, five data collections from a variety of sources were used to compile a large standardized database, which was divided into training, open test, and hidden test subsets. Gold-standard fetal QRS and QT interval annotations were developed using a novel crowd-sourcing framework. The challenge organizers used the hidden test subset to evaluate 91 open-source software entries submitted by 53 international teams of participants in three challenge events, estimating FHR, FRR, and FQT using the hidden test subset, which was not available for study by participants. Two additional events required only user-submitted QRS annotations to evaluate FHR and FRR estimation accuracy using the open test subset available to participants. The challenge yielded a total of 91 open-source software entries. The best of these achieved average estimation errors of 187bpm 2 for FHR, 20.9 ms for FRR, and 152.7 ms for FQT. The open data sets, scoring software, and open-source entries are available at PhysioNet for researchers interested on working on these problems.
A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components
NASA Technical Reports Server (NTRS)
Mejia, M.; Creason, A. S.; Toncich, S. S.; Ebihara, B. T.; Miranda, F. A.
1996-01-01
The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.
Jacob, Joshua; Desai, Ankit; Trompeter, Alex
2017-01-01
Currently, approximately half of all hip fractures are extracapsular, with an incidence as high as 50 in 100,000 in some countries. The common classification systems fail to explain the logistics of fracture classification and whether they all behave in the same manner. The Muller AO classification system is a useful platform to delineate stable and unstable fractures. The Dynamic hip screw (DHS) however, has remained the ‘gold standard’ implant of choice for application in all extracapsular fractures. The DHS relies on the integrity and strength of the lateral femoral wall as well as the postero-medial fragment. An analysis of several studies indicates significant improvements in design and techniques to ensure a better outcome with intramedullary nails. This article reviews the historical trends that helped to evolve the DHS implant as well as discussing if the surgeon should remain content with this implant. We suggest that the gold standard surgical management of extracapsular fractures can, and should, evolve. PMID:29290858
Marcato, Laura; Sandler, Jonathan
2018-04-01
Since digital technology made dental photography widely available, photographers have been trying to establish the 'gold standard' when obtaining intra-oral photographs. A basic knowledge of photographic principles, familiarity with particular dental techniques and a correct choice and use of equipment contribute significantly both to the standardisation and quality of photographs. A recent survey between members of the Institute of Medical Illustrators shed a light on the current practice in the UK. Medical photographers do not always have access to the full range of suitable equipment. A better selection of retractors and occlusal mirrors would undoubtedly contribute to higher quality images.
Roberts, C Michael; Lopez-Campos, Jose Luis; Pozo-Rodriguez, Francisco; Hartl, Sylvia
2013-12-01
Understanding how European care of chronic obstructive pulmonary disease (COPD) admissions vary against guideline standards provides an opportunity to target appropriate quality improvement interventions. In 2010-2011 an audit of care against the 2010 'Global initiative for chronic Obstructive Lung Disease' (GOLD) standards was performed in 16 018 patients from 384 hospitals in 13 countries. Clinicians prospectively identified consecutive COPD admissions over a period of 8 weeks, recording clinical care measures on a web-based data tool. Data were analysed comparing adherence to 10 key management recommendations. Adherence varied between hospitals and across countries. The lack of available spirometry results and variable use of oxygen and non-invasive ventilation (NIV) are high impact areas identified for improvement.
Gold-standard evaluation of a folksonomy-based ontology learning model
NASA Astrophysics Data System (ADS)
Djuana, E.
2018-03-01
Folksonomy, as one result of collaborative tagging process, has been acknowledged for its potential in improving categorization and searching of web resources. However, folksonomy contains ambiguities such as synonymy and polysemy as well as different abstractions or generality problem. To maximize its potential, some methods for associating tags of folksonomy with semantics and structural relationships have been proposed such as using ontology learning method. This paper evaluates our previous work in ontology learning according to gold-standard evaluation approach in comparison to a notable state-of-the-art work and several baselines. The results show that our method is comparable to the state-of the art work which further validate our approach as has been previously validated using task-based evaluation approach.
Building gold standard corpora for medical natural language processing tasks.
Deleger, Louise; Li, Qi; Lingren, Todd; Kaiser, Megan; Molnar, Katalin; Stoutenborough, Laura; Kouril, Michal; Marsolo, Keith; Solti, Imre
2012-01-01
We present the construction of three annotated corpora to serve as gold standards for medical natural language processing (NLP) tasks. Clinical notes from the medical record, clinical trial announcements, and FDA drug labels are annotated. We report high inter-annotator agreements (overall F-measures between 0.8467 and 0.9176) for the annotation of Personal Health Information (PHI) elements for a de-identification task and of medications, diseases/disorders, and signs/symptoms for information extraction (IE) task. The annotated corpora of clinical trials and FDA labels will be publicly released and to facilitate translational NLP tasks that require cross-corpora interoperability (e.g. clinical trial eligibility screening) their annotation schemas are aligned with a large scale, NIH-funded clinical text annotation project.
From Standards to Frameworks for IL: How the ACRL Framework Addresses Critiques of the Standards
ERIC Educational Resources Information Center
Foasberg, Nancy M.
2015-01-01
The Association of College and Research Libraries (ACRL) Information Literacy Competency Standards for Higher Education, since their publication in 2000, have drawn criticism for ignoring the social and political aspects of information literacy. The ACRL Information Literacy Competency Standards Task Force responded with the Framework for…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-25
...-01] NIST Framework and Roadmap for Smart Grid Interoperability Standards, Release 2.0 (Draft... draft version of the NIST Framework and Roadmap for Smart Grid Interoperability Standards, Release 2.0... Roadmap for Smart Grid Interoperability Standards, Release 2.0 (Release 2.0) (Draft) for public review and...
A Guide to Developing Collaborative School-Community-Business Partnerships
ERIC Educational Resources Information Center
Luecking, Richard; Deschamps, Ann; Allison, Ruth; Hyatt, Jacque; Stuart, Christy
2015-01-01
The "gold standard" of youth outcomes is when they are achieving employment and pursuing a clear career path. The activities transition and employment initiatives, and the partnerships that support them, are most appropriately judged against this standard. This Guide presents approaches and considerations for the development and…
Gold-standard for computer-assisted morphological sperm analysis.
Chang, Violeta; Garcia, Alejandra; Hitschfeld, Nancy; Härtel, Steffen
2017-04-01
Published algorithms for classification of human sperm heads are based on relatively small image databases that are not open to the public, and thus no direct comparison is available for competing methods. We describe a gold-standard for morphological sperm analysis (SCIAN-MorphoSpermGS), a dataset of sperm head images with expert-classification labels in one of the following classes: normal, tapered, pyriform, small or amorphous. This gold-standard is for evaluating and comparing known techniques and future improvements to present approaches for classification of human sperm heads for semen analysis. Although this paper does not provide a computational tool for morphological sperm analysis, we present a set of experiments for comparing sperm head description and classification common techniques. This classification base-line is aimed to be used as a reference for future improvements to present approaches for human sperm head classification. The gold-standard provides a label for each sperm head, which is achieved by majority voting among experts. The classification base-line compares four supervised learning methods (1- Nearest Neighbor, naive Bayes, decision trees and Support Vector Machine (SVM)) and three shape-based descriptors (Hu moments, Zernike moments and Fourier descriptors), reporting the accuracy and the true positive rate for each experiment. We used Fleiss' Kappa Coefficient to evaluate the inter-expert agreement and Fisher's exact test for inter-expert variability and statistical significant differences between descriptors and learning techniques. Our results confirm the high degree of inter-expert variability in the morphological sperm analysis. Regarding the classification base line, we show that none of the standard descriptors or classification approaches is best suitable for tackling the problem of sperm head classification. We discovered that the correct classification rate was highly variable when trying to discriminate among non-normal sperm heads. By using the Fourier descriptor and SVM, we achieved the best mean correct classification: only 49%. We conclude that the SCIAN-MorphoSpermGS will provide a standard tool for evaluation of characterization and classification approaches for human sperm heads. Indeed, there is a clear need for a specific shape-based descriptor for human sperm heads and a specific classification approach to tackle the problem of high variability within subcategories of abnormal sperm cells. Copyright © 2017 Elsevier Ltd. All rights reserved.
Carrington, Melinda J; Ball, Jocasta; Horowitz, John D; Marwick, Thomas H; Mahadevan, Gnanadevan; Wong, Chiew; Abhayaratna, Walter P; Haluska, Brian; Thompson, David R; Scuffham, Paul A; Stewart, Simon
2013-06-20
Health outcomes associated with atrial fibrillation (AF) continue to be poor and standard management often does not provide clinical stability. The Standard versus Atrial Fibrillation spEcific managemenT studY (SAFETY) compares the efficacy of a post-discharge, nurse-led, multi-disciplinary programme to optimise AF management with usual care. SAFETY is a prospective, multi-centre, randomised controlled trial with blinded-endpoint adjudication. A target of 320 hospitalised patients with a chronic form of AF will be randomised (stratified by "rate" versus "rhythm" control) to usual post-discharge care or the SAFETY Intervention (SI). The SI involves home-based assessment, extensive clinical profiling and the application of optimal gold-standard pharmacology which is individually tailored according to a "traffic light" framework based on clinical stability, risk profile and therapeutic management. The primary endpoint is event-free survival from all-cause death or unplanned readmission during 18-36 months follow-up. Secondary endpoints include rate of recurrent hospital stay, treatment success (i.e. maintenance of rhythm or rate control and/or application of anti-thrombotic therapy without a bleeding event) and cost-efficacy. With study recruitment to be completed in early 2012, the results of this study will be available in early 2014. If positive, SAFETY will represent a potentially cost-effective and readily applicable strategy to improve health outcomes in high risk individuals discharged from hospital with chronic AF. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Sleep disordered breathing analysis in a general population using standard pulse oximeter signals.
Barak-Shinar, Deganit; Amos, Yariv; Bogan, Richard K
2013-09-01
Obstructive sleep apnea reported as the apnea-hypopnea index (AHI) is usually measured in sleep laboratories using a high number of electrodes connected to the patient's body. In this study, we examined the use of a standard pulse oximeter system with an automated analysis based on the photoplethysmograph (PPG) signal for the diagnosis of sleep disordered breathing. Using a standard and simple device with high accuracy might provide a convenient diagnostic or screening solution for patient evaluation at home or in other out of center testing environments. The study included 140 consecutive patients that were referred routinely to a sleep laboratory [SleepMed Inc.] for the diagnosis of sleep disordered breathing. Each patient underwent an overnight polysomnography (PSG) study according to AASM guidelines in an AASM-accredited sleep laboratory. The automatic analysis is based on photoplethysmographic and saturation signals only. Those two signals were recorded for the entire night as part of the full overnight PSG sleep study. The AHI calculated from the PPG analysis is compared to the AHI calculated from the manual scoring gold standard full PSG. The AHI and total respiratory events measured by the pulse oximeter analysis correlated very well with the corresponding results obtained by the gold standard full PSG. The sensitivity and specificity of AHI = or > 5 and 15 levels measured by the analysis are both above 90 %. The sensitivity and positive predictive value for the detection of respiratory event are both above 84 %. The tested system in this study yielded an acceptable result of sleep disordered breathing compared to the gold standard PSG in patients with moderate to severe sleep apnea. Accordingly and given the convenience and simplicity of the standard pulse oximeter device, the new system can be considered suitable for home and ambulatory diagnosis or screening of sleep disordered breathing patients.
Raluy-Callado, Mireia; Lambrelli, Dimitra; MacLachlan, Sharon; Khalid, Javaria Mona
2015-01-01
In 2013, the Global Initiative for Chronic Obstructive Lung Disease (GOLD) updated the management strategy on COPD based on severity using a combined assessment of symptoms, degree of airflow limitation, and number of exacerbations. This study quantified prevalence and incidence of COPD in the United Kingdom and estimated disease severity by GOLD 2013 categories A/B (low risk) and C/D (high risk). The Clinical Practice Research Datalink was used to identify COPD patients ≥40 years. Patient characteristics were described, and prevalence was calculated on December 31, 2013. Five-year incidence (2009-2013) was estimated, with rates standardized using 2011 UK population age and sex. To classify patients by GOLD categories, spirometry results, the modified British Medical Research Council grade, and history of exacerbations were used. The prevalent cohort comprised 49,286 patients with COPD with mean age 70 years; 51.0% were male. Overall prevalence was 33.3 per 1,000 persons (95% confidence interval [CI]: 33.1-33.6); 66.4% were classified as GOLD A/B and 33.6% as C/D. The standardized prevalence of GOLD A/B was 21.9 per 1,000 persons (95% CI: 21.7-22.1) and of C/D was 11.1 (95% CI: 10.9-11.2). A total of 27,224 newly diagnosed COPD patients were identified with mean age 67 years at diagnosis; 53.0% were male. Incidence was 2.2 per 1,000 person-years (95% CI: 2.2-2.3); 68.7% were classified in categories A/B and 31.3% in C/D, of which 17.2% did not receive COPD maintenance medication. A third of COPD patients in the UK are considered high risk (GOLD 2013 categories C/D), and a third of patients are diagnosed for the first time at these severe stages. Given the progressive nature of the disease, results suggest that closer attention to respiratory symptoms for early detection, diagnosis, and appropriate treatment of COPD in the UK is warranted.
Soomro, Rubina; Ahmed, M. Jamaluddin; Memon, Najma; Khan, Humaira
2008-01-01
A simple high sensitive, selective, and rapid spectrophotometric method for the determination of trace gold based on the rapid reaction of gold(III) with bis(salicylaldehyde)orthophenylenediamine (BSOPD) in aqueous and micellar media has been developed. BSOPD reacts with gold(III) in slightly acidic solution to form a 1:1 brownish-yellow complex, which has an maximum absorption peak at 490 nm in both aqueous and micellar media. The most remarkable point of this method is that the molar absorptivities of the gold-BSOPD complex form in the presence of the nonionic TritonX-100 surfactant are almost a 10 times higher than the value observed in the aqueous solution, resulting in an increase in the sensitivity and selectivity of the method. The apparent molar absorptivities were found to be 2.3 × 104 L mol−1 cm−1 and 2.5 × 105 L mol−1 cm−1 in aqueous and micellar media, respectively. The reaction is instantaneous and the maximum absorbance was obtained after 10 min at 490 nm and remains constant for over 24 h at room temperature. The linear calibration graphs were obtained for 0.1–30 mg L−1 and 0.01–30 mg L−1 of gold(III) in aqueous and surfactant media, respectively. The interference from over 50 cations, anions and complexing agents has been studied at 1 mg L−1 of Au(III); most metal ions can be tolerated in considerable amounts in aqueous micellar solutions. The Sandell’s sensitivity, the limit of detection and relative standard deviation (n = 9) were found to be 5 ng cm−2, 1 ng mL−1 and 2%, respectively in aqueous micellar solutions. Its sensitivity and selectivity are remarkably higher than that of other reagents in the literature. The proposed method was successfully used in the determination of gold in several standard reference materials (alloys and steels), environmental water samples (potable and polluted), and biological samples (blood and urine), geological, soil and complex synthetic mixtures. The results obtained agree well with those samples analyzed by atomic absorption spectrophotometry (AAS). PMID:19609392
Truong, Quynh A; Knaapen, Paul; Pontone, Gianluca; Andreini, Daniele; Leipsic, Jonathon; Carrascosa, Patricia; Lu, Bin; Branch, Kelley; Raman, Subha; Bloom, Stephen; Min, James K
2015-10-01
Dual-energy CT (DECT) has potential to improve myocardial perfusion for physiologic assessment of coronary artery disease (CAD). Diagnostic performance of rest-stress DECT perfusion (DECTP) is unknown. DECIDE-Gold is a prospective multicenter study to evaluate the accuracy of DECT to detect hemodynamic (HD) significant CAD, as compared to fractional flow reserve (FFR) as a reference standard. Eligible participants are subjects with symptoms of CAD referred for invasive coronary angiography (ICA). Participants will undergo DECTP, which will be performed by pharmacological stress, and participants will subsequently proceed to ICA and FFR. HD-significant CAD will be defined as FFR ≤ 0.80. In those undergoing myocardial stress imaging (MPI) by positron emission tomography (PET), single photon emission computed tomography (SPECT) or cardiac magnetic resonance (CMR) imaging, ischemia will be graded by % ischemic myocardium. Blinded core laboratory interpretation will be performed for CCTA, DECTP, MPI, ICA, and FFR. Primary endpoint is accuracy of DECTP to detect ≥1 HD-significant stenosis at the subject level when compared to FFR. Secondary and tertiary endpoints are accuracies of combinations of DECTP at the subject and vessel levels compared to FFR and MPI. DECIDE-Gold will determine the performance of DECTP for diagnosing ischemia.
Self-Assembled Monolayers of Dithiophosphinic Acids on Gold
NASA Astrophysics Data System (ADS)
San Juan, Ronan Roca
This dissertation reports the synthesis of derivatives of dithiophosphinic acids (R1R2DTPAs), and the formation and characterization of DTPA SAMs on gold to build a knowledge base on their nature of binding, organization of the alkyl chains and electrochemical barrier properties. The binding of DTPA molecules on gold depends on the morphology of the gold film: They bind in a mixed monodentate and bidentate modes on standard as-deposited (As-Dep) gold, while they fully chelate on smoother template-stripped (TS) gold. Chapter 2 focuses on van der Waals interactions of various alkyl chain lengths of symmetrical R2DTPA SAMs, which increase with increasing chain lengths similar to those of the analogous n-alkanethiol SAMs, but with alkyl chains that are generally less dense than those of n-alkanethiol SAMs. Chapter 3 addresses why the DTPA compounds do not chelate on the standard As-Dep gold by comparing (C16)2DTPA SAM to (C16 )2DDP SAM. Here, side chain crystallinity stabilizes DTPA SAM structure at the expense of chelation of the DTPA molecules, which leads to a mixture of bidentate and monodentate DTPA molecules, whereas the increased flexibility of the chains in DDP due to the oxygen atoms retains chelation of the DDP molecules. Chapter 4 focuses on the SAMs formed from RlongRshort DTPAs, which shows that the length of the short chain spacer affects SAM packing density and thickness. The SAMs of these molecules also show homogeneous mixing of Rlong and Rshort chains. Chapter 5 investigates PhRDTPA SAMs in preparation for molecular junction studies. The chelation of PhRDTPA molecules on TS gold allows the PhRDTPAs to act as molecular alligator clips. The length of the alkyl chains controls the density of the phenyl group and they fill in the voids between adsorbates to prevent electrical shorting. Finally, Chapter 6 incorporates OH tail group(s) to control the wettability of DTPA SAMs. The presence of OH groups in DTPAs forms hydrophilic SAMs. The symmetrical OH-terminated DTPA forms a SAM with similar packing density to that of an analogous CH3-terminated DTPA SAM, while the OH/CH 3-terminated DTPA forms a thin SAM with low molecular packing, however, the chains of this SAM are homogeneously mixed.
[Expert investigation on food safety standard system framework construction in China].
He, Xiang; Yan, Weixing; Fan, Yongxiang; Zeng, Biao; Peng, Zhen; Sun, Zhenqiu
2013-09-01
Through investigating food safety standard framework among food safety experts, to summarize the basic elements and principles of food safety standard system, and provide policy advices for food safety standards framework. A survey was carried out among 415 experts from government, professional institutions and the food industry/enterprises using the National Food Safety Standard System Construction Consultation Questionnaire designed in the name of the Secretariat of National Food Safety Standard Committee. Experts have different advices in each group about the principles of food product standards, food additive product standards, food related product standards, hygienic practice, test methods. According to the results, the best solution not only may reflect experts awareness of the work of food safety standards situation, but also provide advices for setting and revision of food safety standards for the next. Through experts investigation, the framework and guiding principles of food safety standard had been built.
Preparation of gold nanoparticles and determination of their particles size via different methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iqbal, Muhammad; Usanase, Gisele; Oulmi, Kafia
Graphical abstract: Preparation of gold nanoparticles via NaBH{sub 4} reduction method, and determination of their particle size, size distribution and morphology by using different techniques. - Highlights: • Gold nanoparticles were synthesized by NaBH{sub 4} reduction method. • Excess of reducing agent leads to tendency of aggregation. • The particle size, size distribution and morphology were investigated. • Particle size was determined both experimentally as well as theoretically. - Abstract: Gold nanoparticles have been used in various applications covering both electronics, biosensors, in vivo biomedical imaging and in vitro biomedical diagnosis. As a general requirement, gold nanoparticles should be preparedmore » in large scale, easy to be functionalized by chemical compound of by specific ligands or biomolecules. In this study, gold nanoparticles were prepared by using different concentrations of reducing agent (NaBH{sub 4}) in various formulations and their effect on the particle size, size distribution and morphology was investigated. Moreover, special attention has been dedicated to comparison of particles size measured by various techniques, such as, light scattering, transmission electron microscopy, UV spectrum using standard curve and particles size calculated by using Mie theory and UV spectrum of gold nanoparticles dispersion. Particle size determined by various techniques can be correlated for monodispersed particles and excess of reducing agent leads to increase in the particle size.« less
Jimenez-Del-Toro, Oscar; Muller, Henning; Krenn, Markus; Gruenberg, Katharina; Taha, Abdel Aziz; Winterstein, Marianne; Eggel, Ivan; Foncubierta-Rodriguez, Antonio; Goksel, Orcun; Jakab, Andras; Kontokotsios, Georgios; Langs, Georg; Menze, Bjoern H; Salas Fernandez, Tomas; Schaer, Roger; Walleyo, Anna; Weber, Marc-Andre; Dicente Cid, Yashin; Gass, Tobias; Heinrich, Mattias; Jia, Fucang; Kahl, Fredrik; Kechichian, Razmig; Mai, Dominic; Spanier, Assaf B; Vincent, Graham; Wang, Chunliang; Wyeth, Daniel; Hanbury, Allan
2016-11-01
Variations in the shape and appearance of anatomical structures in medical images are often relevant radiological signs of disease. Automatic tools can help automate parts of this manual process. A cloud-based evaluation framework is presented in this paper including results of benchmarking current state-of-the-art medical imaging algorithms for anatomical structure segmentation and landmark detection: the VISCERAL Anatomy benchmarks. The algorithms are implemented in virtual machines in the cloud where participants can only access the training data and can be run privately by the benchmark administrators to objectively compare their performance in an unseen common test set. Overall, 120 computed tomography and magnetic resonance patient volumes were manually annotated to create a standard Gold Corpus containing a total of 1295 structures and 1760 landmarks. Ten participants contributed with automatic algorithms for the organ segmentation task, and three for the landmark localization task. Different algorithms obtained the best scores in the four available imaging modalities and for subsets of anatomical structures. The annotation framework, resulting data set, evaluation setup, results and performance analysis from the three VISCERAL Anatomy benchmarks are presented in this article. Both the VISCERAL data set and Silver Corpus generated with the fusion of the participant algorithms on a larger set of non-manually-annotated medical images are available to the research community.
Libbrecht, Maxwell W; Bilmes, Jeffrey A; Noble, William Stafford
2018-04-01
Selecting a non-redundant representative subset of sequences is a common step in many bioinformatics workflows, such as the creation of non-redundant training sets for sequence and structural models or selection of "operational taxonomic units" from metagenomics data. Previous methods for this task, such as CD-HIT, PISCES, and UCLUST, apply a heuristic threshold-based algorithm that has no theoretical guarantees. We propose a new approach based on submodular optimization. Submodular optimization, a discrete analogue to continuous convex optimization, has been used with great success for other representative set selection problems. We demonstrate that the submodular optimization approach results in representative protein sequence subsets with greater structural diversity than sets chosen by existing methods, using as a gold standard the SCOPe library of protein domain structures. In this setting, submodular optimization consistently yields protein sequence subsets that include more SCOPe domain families than sets of the same size selected by competing approaches. We also show how the optimization framework allows us to design a mixture objective function that performs well for both large and small representative sets. The framework we describe is the best possible in polynomial time (under some assumptions), and it is flexible and intuitive because it applies a suite of generic methods to optimize one of a variety of objective functions. © 2018 Wiley Periodicals, Inc.
Muver, a computational framework for accurately calling accumulated mutations.
Burkholder, Adam B; Lujan, Scott A; Lavender, Christopher A; Grimm, Sara A; Kunkel, Thomas A; Fargo, David C
2018-05-09
Identification of mutations from next-generation sequencing data typically requires a balance between sensitivity and accuracy. This is particularly true of DNA insertions and deletions (indels), that can impart significant phenotypic consequences on cells but are harder to call than substitution mutations from whole genome mutation accumulation experiments. To overcome these difficulties, we present muver, a computational framework that integrates established bioinformatics tools with novel analytical methods to generate mutation calls with the extremely low false positive rates and high sensitivity required for accurate mutation rate determination and comparison. Muver uses statistical comparison of ancestral and descendant allelic frequencies to identify variant loci and assigns genotypes with models that include per-sample assessments of sequencing errors by mutation type and repeat context. Muver identifies maximally parsimonious mutation pathways that connect these genotypes, differentiating potential allelic conversion events and delineating ambiguities in mutation location, type, and size. Benchmarking with a human gold standard father-son pair demonstrates muver's sensitivity and low false positive rates. In DNA mismatch repair (MMR) deficient Saccharomyces cerevisiae, muver detects multi-base deletions in homopolymers longer than the replicative polymerase footprint at rates greater than predicted for sequential single-base deletions, implying a novel multi-repeat-unit slippage mechanism. Benchmarking results demonstrate the high accuracy and sensitivity achieved with muver, particularly for indels, relative to available tools. Applied to an MMR-deficient Saccharomyces cerevisiae system, muver mutation calls facilitate mechanistic insights into DNA replication fidelity.
Comparison of wheat and rye flour solutions for skin prick testing: a multi-centre study (Stad 1).
van Kampen, V; Merget, R; Rabstein, S; Sander, I; Bruening, T; Broding, H C; Keller, C; Muesken, H; Overlack, A; Schultze-Werninghaus, G; Walusiak, J; Raulf-Heimsoth, M
2009-12-01
Skin prick testing (SPT) is the basic method for diagnosing IgE-mediated allergies. However, skin reactivity is related to the quality of allergen extracts, which are often poorly defined for occupational allergens. To compare wheat and rye flour SPT solutions from different producers. Standardized SPTs were performed in seven allergy centres with wheat and rye flour solutions from four producers in 125 symptomatic bakers. Optimal cut-off levels for weal sizes were assessed with the Youden Index. Comparisons between SPT results of different solutions were made with flour-specific IgE (sIgE) as the gold standard. Sensitivities, specificities, positive and negative predictive values, and test efficiencies were calculated and compared with McNemar and chi(2)-tests. The influence of the choice of the gold standard (sIgE or challenge) test was examined for 95 subjects. Additionally, SPT solutions were analysed for protein and antigen content. The optimal cut-off level for all SPT solutions was a weal size of >or=1.5 mm. While differences between wheat and rye flours were small, differences between producers were important. Variability of sensitivities (0.31-0.96), negative predictive values (0.42-0.91), and test efficiencies (0.54-0.90) were higher than variations of specificities (0.74-1.00) and positive predictive values (0.88-1.00). Similar results were obtained when using challenge test results as the gold standard. Variability could be explained by the different antigen contents of the SPT solutions. There is a wide variability of SPT solutions for wheat and rye flour from different producers, mainly with respect to sensitivities, negative predictive values, and test efficiencies. Improvement and standardization of SPT solutions used for the diagnosis of baker's asthma are highly recommended.
Saha, Sreemanti; Narang, Rahul; Deshmukh, Pradeep; Pote, Kiran; Anvikar, Anup; Narang, Pratibha
2017-01-01
The diagnostic techniques for malaria are undergoing a change depending on the availability of newer diagnostics and annual parasite index of infection in a particular area. At the country level, guidelines are available for selection of diagnostic tests; however, at the local level, this decision is made based on malaria situation in the area. The tests are evaluated against the gold standard, and if that standard has limitations, it becomes difficult to compare other available tests. Bayesian latent class analysis computes its internal standard rather than using the conventional gold standard and helps comparison of various tests including the conventional gold standard. In a cross-sectional study conducted in a tertiary care hospital setting, we have evaluated smear microscopy, rapid diagnostic test (RDT), and polymerase chain reaction (PCR) for diagnosis of malaria using Bayesian latent class analysis. We found the magnitude of malaria to be 17.7% (95% confidence interval: 12.5%-23.9%) among the study subjects. In the present study, the sensitivity of microscopy was 63%, but it had very high specificity (99.4%). Sensitivity and specificity of RDT and PCR were high with RDT having a marginally higher sensitivity (94% vs. 90%) and specificity (99% vs. 95%). On comparison of likelihood ratios (LRs), RDT had the highest LR for positive test result (175) and the lowest LR for negative test result (0.058) among the three tests. In settings like ours conventional smear microscopy may be replaced with RDT and as we move toward elimination and facilities become available PCR may be roped into detect cases with lower parasitaemia.
Hernández, Marcos; García, Gabriel; Falco, Jimena; García, Agustín R; Martín, Vanina; Ibarrola, Manuel; Quadrelli, Silvia
2018-01-01
The objective of this study was to examine how COPD patients were classified by the Global Initiative for Chronic Obstructive Lung Disease (GOLD) spirometry-based severity system and the distribution of COPD severity using the new GOLD 2011 assessment framework. This was an observational, retrospective cohort study conducted in a single tertiary center on a prospective database, which aimed to evaluate the prevalence, incidence, severity, and comorbidities of COPD. Inclusion criteria were age ≥40 years and COPD diagnosis according to GOLD 2007 classification. Clinical factors were compared between the categories in GOLD 2007 and 2011 groups by using the χ 2 test for categorical data and the analysis of variance for continuous data. In total, 420 COPD patients were included in the analysis. The distribution of patients into GOLD 2007 categories was as follows: 6.4% (n=27) of them were classified into subgroup I, 42.1% (n=177) into subgroup II, 37.9% (n=159) into subgroup III, and 13.6% (n=57) into subgroup IV. The distribution of patients into GOLD 2011 categories was as follows: 16.4% (n=69) of them were classified into subgroup A (low risk and fewer symptoms), 32.1% (n=135) into subgroup B (low risk and more symptoms), 21.6% (n=91) into subgroup C (high risk and fewer symptoms), and 29.7% (n=125) into subgroup D (high risk and more symptoms). After the application of the new GOLD 2011 (modified Medical Research Council [mMRC] system), 22% (n=94) of patients were upgraded to a higher level than their spirometry level, and 16.2% (n=68) of them were downgraded in their severity category, meaning that almost 40% of patients changed their severity assessment category. In total, 22% of patients in stage I were allocated to group B, and 35% of patients in stage IV were allocated to group C. Patients in stage III were the most frequently upgraded to a higher risk group (D), taking into account mMRC and exacerbation history. Classifying patients using the new GOLD 2011 criteria reallocated a relevant proportion of patients to a different risk category and identified larger proportions of patients in the mildest and more severe groups compared with GOLD 2007 classification.
Effect of Gold Marker Seeds on Magnetic Resonance Spectroscopy of the Prostate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hossain, Murshed, E-mail: Murshed.Hossain@fccc.edu; Schirmer, Timo; Richardson, Theresa
2012-05-01
Purpose: Magnetic resonance stereoscopic imaging (MRSI) of the prostate is an emerging technique that may enhance targeting and assessment in radiotherapy. Current practices in radiotherapy invariably involve image guidance. Gold seed fiducial markers are often used to perform daily prostate localization. If MRSI is to be used in targeting prostate cancer and therapy assessment, the impact of gold seeds on MRSI must be investigated. The purpose of this study was to quantify the effects of gold seeds on the quality of MRSI data acquired in phantom experiments. Methods and Materials: A cylindrical plastic phantom with a spherical cavity 10 centimetersmore » in diameter wss filled with water solution containing choline, creatine, and citrate. A gold seed fiducial marker was put near the center of the phantom mounted on a plastic stem. Spectra were acquired at 1.5 Tesla by use of a clinical MRSI sequence. The ratios of choline + creatine to citrate (CC/Ci) were compared in the presence and absence of gold seeds. Spectra in the vicinity of the gold seed were analyzed. Results: The maximum coefficient of variation of CC/Ci induced by the gold seed was found to be 10% in phantom experiments at 1.5 T. Conclusion: MRSI can be used in prostate radiotherapy in the presence of gold seed markers. Gold seeds cause small effects (in the order of the standard deviation) on the ratio of the metabolite's CC/Ci in the phantom study done on a 1.5-T scanner. It is expected that gold seed markers will have similar negligible effect on spectra from prostate patients. The maximum of 10% of variation in CC/Ci found in the phantom study also sets a limit on the threshold accuracy of CC/Ci values for deciding whether the tissue characterized by a local spectrum is considered malignant and whether it is a candidate for local boost in radiotherapy dose.« less
NASA Astrophysics Data System (ADS)
Luan Truong, Xuan; Luong Le, Van; Quang Truong, Xuan
2015-04-01
Daksa gold deposit is the biggest gold deposits in Vietnam. The Daksa geological structure complicated, distributed mainly metamorphosed sedimentary NuiVu formation (PR3-?1nv2). The sulfide gold ore bodies distributed in quartz schist, quartz - biotite related to faut and distribution wing anticline. The gold ore bodies form circuits, network circuits, circuits lenses; fill the cup surface layer of the developing northeast - southwest; is the less than or west longitude north - SE. The results show that, Au and accompanying elements (Ag, Pb and Zn) have correlated pretty closely. All of its consistent with the logarithmic distribution standard, in accordance with the law of distribution of content mineral rare. The structure functions have nugget effect and spherical models with show that Au and accompanying elements special variation are changes. Au contents shown local anisotropy, no clearly anisotropy (K=1,17) and weakly anisotropy (K=1,4). Intensity mineralization of the ore bodies are quite high with demand spherical conversion coefficient ranging from 0.49 to 0.75 and from 0.66 to 0.97 (for other body). With nugget effects, ore bodies shown that it is consistent with mineralization in the ore bodies study, ore erasable, micro vein, infilling fractures in quartz vein. All of variogram presents local anisotropy, indicated gold mineralization at study area has least two-mineralization stages, consistent with the analysis of mineralography samples. By the results of the structure function study, the authors present the system optimization for exploration deposit and used to evaluate gold reserves by Ordinary Kriging. High accuracy of Kriging estimation results are expressed in the minimum Kriging variance, by compare the results calculated by some other methods (such as distance inverse weighting method, ..) and specially compare to the results of a some blocks have been exploited. Key words: Geostat and gold deposits VN. Daksa and gold mineralization. Geostat and gold mine Daksa.
ERIC Educational Resources Information Center
New Zealand Qualifications Authority, Wellington.
This booklet includes the latest list of unit standards and qualifications registered on the New Zealand National Qualifications Framework to April 1994. Unit standards registered on the framework can be offered by private and government training establishments, polytechnics, colleges of education, and schools. This list of registered unit…
Conversion of CO2 and C2H6 to propanoic acid over a Au-exchanged MCM-22 zeolite.
Sangthong, Winyoo; Probst, Michael; Limtrakul, Jumras
2014-02-24
Finding novel catalysts for the direct conversion of CO2 to fuels and chemicals is a primary goal in energy and environmental research. In this work, density functional theory (DFT) is used to study possible reaction mechanisms for the conversion of CO2 and C2H6 to propanoic acid over a gold-exchanged MCM-22 zeolite catalyst. The reaction begins with the activation of ethane to produce a gold ethyl hydride intermediate. Hydrogen transfers to the framework oxygen leads then to gold ethyl adsorbed on the Brønsted-acid site. The energy barriers for these steps of ethane activation are 9.3 and 16.3 kcal mol(-1), respectively. Two mechanisms of propanoic acid formation are investigated. In the first one, the insertion of CO2 into the Au-H bond of the first intermediate yields gold carboxyl ethyl as subsequent intermediate. This is then converted to propanoic acid by forming the relevant C-C bond. The activation energy of the rate-determining step of this pathway is 48.2 kcal mol(-1). In the second mechanism, CO2 interacts with gold ethyl adsorbed on the Brønsted-acid site. Propanoic acid is formed via protonation of CO2 by the Brønsted acid and the simultaneous formation of a bond between CO2 and the ethyl group. The activation energy there is 44.2 kcal mol(-1), favoring this second pathway at least at low temperatures. Gold-exchanged MCM-22 zeolite can therefore, at least in principle, be used as the catalyst for producing propanoic acid from CO2 and ethane. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Time-frequency featured co-movement between the stock and prices of crude oil and gold
NASA Astrophysics Data System (ADS)
Huang, Shupei; An, Haizhong; Gao, Xiangyun; Huang, Xuan
2016-02-01
The nonlinear relationships among variables caused by the hidden frequency information complicate the time series analysis. To shed more light on this nonlinear issue, we examine their relationships in joint time-frequency domain with multivariate framework, and the analyses in the time domain and frequency domain serve as comparisons. The daily Brent oil prices, London gold fixing price and Shanghai Composite index from January 1991 to September 2014 are adopted as example. First, they have long-term cointegration relationship in time domain from holistic perspective. Second, the Granger causality tests in different frequency bands are heterogeneous. Finally, the comparison between results from wavelet coherence and multiple wavelet coherence in the joint time-frequency domain indicates that in the high (1-14 days) and medium frequency (14-128 days) bands, the combination of Brent and gold prices has stronger correlation with the stock. In the low frequency band (256-512 days), year 2003 is the structure broken point before which Brent and oil are ideal choice for hedging the risk of the stock market. Thus, this paper offers more details between the Chinese stock market and the commodities markets of crude oil and gold, which suggests that the decisions for different time and frequencies should consider the corresponding benchmark information.
Liu, Bing; Wang, Lingling; Tong, Bei; Zhang, Yan; Sheng, Wei; Pan, Mingfei; Wang, Shuo
2016-11-15
In this study, the three nanomaterials: colloidal gold, nanogold-polyaniline-nanogold microspheres (GPGs) and colloidal carbon were respectively labeled with the antibody against salbutamol (SAL). We aimed to develop immunochromatographic strips with these nanomaterial labels and determine their performance in visual detection of SAL. For the colloidal gold-based strip, the detection limit of SAL was 1.0µgL(-1) in standard solution and 5.0µgkg(-1) in meat samples. For the GPG- and colloidal carbon-based strips, the limit of detection was 2.0µgL(-1) in standard solution and 10µgkg(-1) in meat samples. The results obtained using the test strips were found to be highly consistent with those obtained using a commercial kit, indicating the high accuracy of these strips. The three strips were also found to be stable up to 18 weeks under laboratory conditions. In terms of sensitivity, the colloidal gold-based strip was slightly better than the other two. For the GPG- and colloidal carbon-based strips, the difference between the results obtained for different batches was small (high consistency), and the stability was much better than that of the colloidal gold-based one. Our results indicate that colloidal carbon can be used as a label in immunochromatographic tests; it can also help reduce the cost involved and scale-up the production. The use of immunochromatographic test strips labeled with colloidal carbon can be a rapid and inexpensive method for SAL assays in on-site applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Prehospital Emergencies in Illegal Gold Mining Sites in French Guiana.
Egmann, Gérald; Tattevin, Pierre; Palancade, Renaud; Nacher, Matthieu
2018-03-01
Illegal gold mining is flourishing in French Guiana, existing outside the law due to both the high cost of gold mining permits and the challenges of law enforcement within the Amazon forest. We report the characteristics of, and the medical responses to, medical emergencies in illegal gold mining sites. We performed a retrospective study of all medical emergencies reported from illegal gold mining sites to the centralized call office of SAMU 973 from 1998 through 2000 and from 2008 through 2010. According to the national health care system, any medical emergency within the territory is handled by the prehospital emergency medical service (SAMU 973), irrespective of the patients' legal status. Data were extracted from the SAMU 973 notebook registry (1998-2000) or the SAMU 973 computerized database (2008-2010) and werre collected using a standardized questionnaire. Of 71,932 calls for medical emergencies in French Guiana during the study periods, 340 (0.5%) originated from illegal gold mining sites. Of these, 196 (58%) led to medical evacuation by helicopter, whereas the overall rate of evacuation by helicopter after placing a call to SAMU 973 was only 4% (3020/71,932; P<0.0001 for comparison with illegal gold mining sites). Medical emergencies were classified as illness (48%, mostly infectious), trauma (44%, mostly weapon wounds), and miscellaneous (8%). Medical emergencies at illegal gold mining sites in the Amazon forest mostly include infectious diseases, followed by trauma, and often require medical evacuation by helicopter. Our study suggests that implementation of preventive medicine within gold mining sites, irrespective of their legal status, could be cost-effective and reduce morbidity. Copyright © 2017 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
... Formaldehyde; Third-Party Certification Framework for the Formaldehyde Standards for Composite Wood Products..., concerning a third-party certification framework for the formaldehyde standards for composite wood products... Environmental protection, Composite wood products, Formaldehyde, Reporting and recordkeeping, Third-party...
Beyond the Great Wall: gold of the silk roads and the first empire of the steppes.
Radtke, Martin; Reiche, Ina; Reinholz, Uwe; Riesemeier, Heinrich; Guerra, Maria F
2013-02-05
Fingerprinting ancient gold work requires the use of nondestructive techniques with high spatial resolution (down to 25 μm) and good detection limits (micrograms per gram level). In this work experimental setups and protocols for synchrotron radiation induced X-ray fluorescence (SRXRF) at the BAMline of the Berlin electron storage ring company for synchrotron radiation (BESSY) in Berlin for the measurement of characteristic trace elements of gold are compared considering the difficulties, shown in previous works, connected to the quantification of Pt. The best experimental conditions and calculation methods were achieved by using an excitation energy of 11.58 keV, a silicon drift chamber detector (SDD) detector, and pure element reference standards. A detection limit of 3 μg/g has been reached. This newly developed method was successfully applied to provenancing the Xiongnu gold from the Gol Mod necropolis, excavated under the aegis of the United Nations Educational, Scientific and Cultural Organization (UNESCO). The composition of the base alloys and the presence of Pt and Sn showed that, contrary to what is expected, the gold foils from the first powerful empire of the steppes along the Great Wall were produced with alluvial gold from local placer deposits located in Zaamar, Boroo, and in the Selenga River.
Myochrysine Solution Structure and Reactivity
Jones, William B.; Zhao, Zheng; Dorsey, John G.; Tepperman, Katherine
1994-01-01
We have determined the framework structure of Myochrysine (disodium gold(I)thiomalate) in the solid state and extremely concentrated aqueous solution, previously. It consists of an open chain polymer with linear gold coordination to two thiolates from the thiomalic acid moieties which bridge between pairs of gold atoms providing an Au-S-Au angle of 95°. The question remained: was this structure relevant to the dilute solutions of drugs administered and the still lower concentrations of gold found in the bodies of patients (typically 1 ppm Au in blood and urine or 5 μM in Au). We have provided an answer to that question using extended X-ray absorption spectroscopy (EXAFS) and capillary zone electrophoresis (CZE). EXAFS studies confirm that the polymeric structure with two sulfur atoms per gold atom persists from molar concentrations down to millimolar concentrations. CZE is able to separate and detect Myochrysine at millimolar levels. More importantly, at micromolar levels Myochrysine solutions exhibit identical CZE behavior to that measured at millimolar levels. Thus, aqueous solutions of the drug remain oligomeric at concentrations commensurate with those found in patient blood and urine. The reactivity of Myochrysine with cyanide, a species especially prevalent in smoking patients, was explored using CZE. Cyanide freely replaces thiomalic acid to form [Au(CN)2]- and thiomalic acid via a mixed ligand intermediate. The overall apparent equilibrium constant (Kapp) for the reaction is 6×10-4M-1. Further reaction of [Au(CN)2]- with a large excess of L, where L is cysteine, N-acetylcysteine, or glutathione, shows that these amino acids readily replace cyanide to form [AuL2]-. These species are thus potential metabolites and could possibly be active forms of gold in vivo. That all of these species are readily separated and quantified using CZE demonstrates that capillary electrophoresis is an accessible and powerful tool to add to those used for the study of gold-based antiarthritis drugs. PMID:18476256
Whiteley, M S; Dos Santos, S J; Harrison, C C; Holdstock, J M; Lopez, A J
2015-12-01
To assess the suitability of transvaginal duplex ultrasonography to identify pathological reflux in the ovarian and internal iliac veins in women. A retrospective study of patients treated in 2011 and 2012 was performed in a specialised vein clinic. Diagnostic transvaginal duplex ultrasonography in women presenting with symptoms or signs of pelvic vein reflux were compared with the outcomes of treatment from pelvic vein embolisation. A repeat transvaginal duplex ultrasonography was performed 6 weeks later by a blinded observer and any residual reflux was identified. Results from 100 sequential patients were analysed. Mean age 44.2 years (32-69) with mode average parity of 3 (0-5 deliveries). Pre-treatment, 289/400 veins were refluxing (ovarian - 29 right, 81 left; internal iliac - 93 right, 86 left). Coil embolisation was successful in 86/100 patients and failed partially in 14/100 - 5 due to failure to cannulate the target vein. One false-positive diagnosis was made. Currently there is no accepted gold standard for pelvic vein incompetence. Comparing transvaginal duplex ultrasonography with the outcome from selectively treating the veins identified as having pathological reflux with coil embolisation, there were no false-negative diagnoses and only one false-positive. This study suggests that transvaginal duplex ultrasonography could be the gold standard in assessing pelvic vein reflux. © The Author(s) 2014.
Epidural technique for postoperative pain: gold standard no more?
Rawal, Narinder
2012-01-01
Epidural analgesia is a well-established technique that has commonly been regarded as the gold standard in postoperative pain management. However, newer, evidence-based outcome data show that the benefits of epidural analgesia are not as significant as previously believed. There are some benefits in a decrease in the incidence of cardiovascular and pulmonary complications, but these benefits are probably limited to high-risk patients undergoing major abdominal or thoracic surgery who receive thoracic epidural analgesia with local anaesthetic drugs only. There is increasing evidence that less invasive regional analgesic techniques are as effective as epidural analgesia. These include paravertebral block for thoracotomy, femoral block for total hip and knee arthroplasty, wound catheter infusions for cesarean delivery, and local infiltration analgesia techniques for lower limb joint arthroplasty. Wound infiltration techniques and their modifications are simple and safe alternatives for a variety of other surgical procedures. Although pain relief associated with epidural analgesia can be outstanding, clinicians expect more from this invasive, high-cost, labour-intensive technique. The number of indications for the use of epidural analgesia seems to be decreasing for a variety of reasons. The decision about whether to continue using epidural techniques should be guided by regular institutional audits and careful risk-benefit assessment rather than by tradition. For routine postoperative analgesia, epidural analgesia may no longer be considered the gold standard.
Mapping Partners Master Drug Dictionary to RxNorm using an NLP-based approach.
Zhou, Li; Plasek, Joseph M; Mahoney, Lisa M; Chang, Frank Y; DiMaggio, Dana; Rocha, Roberto A
2012-08-01
To develop an automated method based on natural language processing (NLP) to facilitate the creation and maintenance of a mapping between RxNorm and a local medication terminology for interoperability and meaningful use purposes. We mapped 5961 terms from Partners Master Drug Dictionary (MDD) and 99 of the top prescribed medications to RxNorm. The mapping was conducted at both term and concept levels using an NLP tool, called MTERMS, followed by a manual review conducted by domain experts who created a gold standard mapping. The gold standard was used to assess the overall mapping between MDD and RxNorm and evaluate the performance of MTERMS. Overall, 74.7% of MDD terms and 82.8% of the top 99 terms had an exact semantic match to RxNorm. Compared to the gold standard, MTERMS achieved a precision of 99.8% and a recall of 73.9% when mapping all MDD terms, and a precision of 100% and a recall of 72.6% when mapping the top prescribed medications. The challenges and gaps in mapping MDD to RxNorm are mainly due to unique user or application requirements for representing drug concepts and the different modeling approaches inherent in the two terminologies. An automated approach based on NLP followed by human expert review is an efficient and feasible way for conducting dynamic mapping. Copyright © 2011 Elsevier Inc. All rights reserved.
The triglyceride and glucose index is useful for recognising insulin resistance in children.
Rodríguez-Morán, M; Simental-Mendía, L E; Guerrero-Romero, F
2017-06-01
Although recognising insulin resistance (IR) in children is particularly important, the gold standard test used to diagnose it, the euglyceamic glucose clamp, is costly, invasive and is not routinely available in our clinical settings in Mexico. This study evaluated whether the triglyceride-glucose (TyG) index would provide a useful alternative. A total of 2779 school children aged seven to 17 years, from Durango, Mexico, were enrolled during 2015-2016. The gold standard euglyceamic-hyperinsulinemic clamp test was performed in a randomly selected subsample of 125 children, and diagnostic concordance between the TyG index and the homoeostasis model assessment of IR was evaluated in all of the 2779 enrolled children. The best cut-off values for recognising IR using the TyG index were 4.65 for prepubertal girls and boys, 4.75 for pubertal girls and 4.70 for pubertal boys. Concordance between the TyG index and the homoeostasis model assessment of IR was 0.910 and 0.902 for the prepubertal girls and boys, 0.932 for the pubertal girls and 0.925 for the pubertal boys. The TyG index was useful for recognising IR in both prepubertal and pubertal children and could provide a feasible alternative to the costly and invasive gold standard test for IR in resource-limited settings. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Classifying obstructive sleep apnea using smartphones.
Al-Mardini, Mamoun; Aloul, Fadi; Sagahyroon, Assim; Al-Husseini, Luai
2014-12-01
Obstructive sleep apnea (OSA) is a serious sleep disorder which is characterized by frequent obstruction of the upper airway, often resulting in oxygen desaturation. The serious negative impact of OSA on human health makes monitoring and diagnosing it a necessity. Currently, polysomnography is considered the gold standard for diagnosing OSA, which requires an expensive attended overnight stay at a hospital with considerable wiring between the human body and the system. In this paper, we implement a reliable, comfortable, inexpensive, and easily available portable device that allows users to apply the OSA test at home without the need for attended overnight tests. The design takes advantage of a smatrphone's built-in sensors, pervasiveness, computational capabilities, and user-friendly interface to screen OSA. We use three main sensors to extract physiological signals from patients which are (1) an oximeter to measure the oxygen level, (2) a microphone to record the respiratory effort, and (3) an accelerometer to detect the body's movement. Finally, we examine our system's ability to screen the disease as compared to the gold standard by testing it on 15 samples. The results showed that 100% of patients were correctly identified as having the disease, and 85.7% of patients were correctly identified as not having the disease. These preliminary results demonstrate the effectiveness of the developed system when compared to the gold standard and emphasize the important role of smartphones in healthcare. Copyright © 2014 Elsevier Inc. All rights reserved.
2012-05-01
LEED system awards points for meeting a variety of standards and certifies buildings as silver, gold , or platinum. The replacement medical center’s...indicate that it may qualify for a “ gold ” certification once it has met the more stringent German design requirements. For example, the project will... Joanne Landesman assisted in the message and report development, Amie Steele assisted in developing the report’s tables and graphics, Jennifer Echard
Midgley, John E M
2011-02-01
To examine the merits of measuring free analytes by ultrafiltration using either diluted or undiluted serum. Confidence in the accuracy of measurements is affected both by problems identified in current systems using semipermeable membranes, the sensitivity of the system to artefacts and comparisons with other imperfect assays. All "gold standard" methods must robustly obey sound physicochemical principles if valid conclusions are to be drawn. Copyright © 2010 Elsevier Inc. All rights reserved.
Neuhaus, Philipp; Doods, Justin; Dugas, Martin
2015-01-01
Automatic coding of medical terms is an important, but highly complicated and laborious task. To compare and evaluate different strategies a framework with a standardized web-interface was created. Two UMLS mapping strategies are compared to demonstrate the interface. The framework is a Java Spring application running on a Tomcat application server. It accepts different parameters and returns results in JSON format. To demonstrate the framework, a list of medical data items was mapped by two different methods: similarity search in a large table of terminology codes versus search in a manually curated repository. These mappings were reviewed by a specialist. The evaluation shows that the framework is flexible (due to standardized interfaces like HTTP and JSON), performant and reliable. Accuracy of automatically assigned codes is limited (up to 40%). Combining different semantic mappers into a standardized Web-API is feasible. This framework can be easily enhanced due to its modular design.
Adhesion of maxillofacial silicone elastomer to a fiber-reinforced composite resin framework.
Kantola, Rosita; Lassila, Lippo; Vallittu, Pekka
2011-01-01
Recently, fiber-reinforced composite resin (FRC) has been introduced as a framework material for maxillofacial silicone prostheses. The purpose of this research was to study the tensile bond strength between a room temperature-polymerized maxillofacial silicone elastomer and a unidirectional FRC. Three different bonding agents were compared. Specimens were loaded in tension mode according to ISO 22401 in a universal testing device with a crosshead speed of 10 mm/min until bonding failure occurred. The influence of the surface characteristics (ground vs intact) was also studied. The highest tensile bond strength was seen with Gold Platinum Primer A-330-G, followed by Sofreliner primer. One-way analysis of variance revealed that the surface treatment of the FRC and the adhesive used had a significant effect on tensile bond strength between silicone and FRC (P < .05). Grinding enhanced adhesion, especially with Gold Platinum Primer A-330-G and Sofreliner primer. The fracture type also changed to more cohesive in nature. The FRC substructure can successfully be bonded to maxillofacial silicone elastomer by using primer containing methyl ethyl ketone and dichloromethane solvent. Bonding can be improved by roughening the FRC substrate via grinding.
Hérault, Damien; Cerveau, Geneviève; Corriu, Robert J P; Mehdi, Ahmad
2011-01-14
In this paper we describe the synthesis of functionalised mesoporous organosilicas containing a mannitol derivative in the framework. For this purpose, a bis-silylated precursor 3,4-Di-O-[3-(triethoxysilylpropyl)carbamate]-1,2:5,6-di-O-isopropylidene-D-mannitol was prepared by coupling of 1,2:5,6-di-O-isopropylidene-D-mannitol with 3-(triethoxysilylpropyl)isocyanate. The framework-functionalised materials were obtained in one step by the "direct synthesis" method which consists of a co-hydrolysis and polycondensation of a bis-silylated mannitol precursor with tetraethylorthosilicate (TEOS) in the presence of a non-ionic triblock co-polymer (P123) as structure-directing agent. Interestingly, deprotection of the 1,2,5,6 OH functional groups occurred during the material synthesis. The obtained solids were characterized by (13)C and (29)Si CP-MAS NMR, N(2) adsorption-desorption, powder X-ray diffraction, TEM and elemental analysis. We have shown that, the OH functional groups, which are released during the synthesis of the mesoporous silica, can be used for chelation of ions and stabilisation of nanoparticles. The subsequent growth of gold (0) nanoparticles in the wall has been investigated and evidenced.
Okeke, Claudia C; Allen, Loyd V
2009-01-01
The standard operating procedures suggested in this article are presented to compounding pharmacies to ensure the quality of the environment in which a CSP is prepared. Since United States Pharmacopeia Chapter 797 provides minimum standards, each facility should aim for best practice gold standard. The standard operating procedures should be tailored to meet the expectations and design of each facility. Compounding personnel are expected to know and understand each standard operating procedure to allow for complete execution of the procedures.
Tiopronin Gold Nanoparticle Precursor Forms Aurophilic Ring Tetramer
Simpson, Carrie A.; Farrow, Christopher L.; Tian, Peng; Billinge, Simon J.L.; Huffman, Brian J.; Harkness, Kellen M.; Cliffel, David E.
2010-01-01
In the two step synthesis of thiolate-monolayer protected clusters (MPCs), the first step of the reaction is a mild reduction of gold(III) by thiols that generates gold(I) thiolate complexes as intermediates. Using tiopronin (Tio) as the thiol reductant, the characterization of the intermediate Au4Tio4 complex was accomplished with various analytical and structural techniques. Nuclear magnetic resonance (NMR), elemental analysis, thermogravimetric analysis (TGA), and matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) were all consistent with a cyclic gold(I)-thiol tetramer structure, and final structural analysis was gathered through the use of powder diffraction and pair distribution functions (PDF). Crystallographic data has proved challenging for almost all previous gold(I)-thiolate complexes. Herein, a novel characterization technique when combined with standard analytical assessment to elucidate structure without crystallographic data proved invaluable to the study of these complexes. This in conjunction with other analytical techniques, in particular mass spectrometry, can elucidate a structure when crystallographic data is unavailable. In addition, luminescent properties provided evidence of aurophilicity within the molecule. The concept of aurophilicity has been introduced to describe a select group of gold-thiolate structures, which possess unique characteristics, mainly red photoluminescence and a distinct Au-Au intramolecular distance indicating a weak metal-metal bond as also evidenced by the structural model of the tetramer. Significant features of both the tetrameric and aurophilic properties of the intermediate gold(I) tiopronin complex are retained after borohydride reduction to form the MPC, including gold(I) tiopronin partial rings as capping motifs, or “staples”, and weak red photoluminescence that extends into the Near Infrared region. PMID:21067183
Liu, Xiao-Qi; Peng, Dan-Hong; Wang, Yan-Ping; Xie, Rong; Chen, Xin-Lin; Yu, Chun-Quan; Li, Xian-Tao
2018-05-03
Phlegm and blood stasis syndrome (PBSS) is one of the main syndromes in coronary heart disease (CHD). Syndromes of Chinese medicine (CM) are lack of quantitative and easyimplementation diagnosis standards. To quantify and standardize the diagnosis of PBSS, scales are usually applied. To evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. Six hundred patients with stable angina pectoris of CHD, 300 in case group and 300 in control group, will be recruited from 5 hospitals across China. Diagnosis from 2 experts will be considered as the "gold standard". The study design consists of 2 phases: pilot test is used to evaluate the reliability and validity, and diagnostic test is used to assess the diagnostic accuracy of the scale, including sensitivity, specififi city, likelihood ratio and area under the receiver operator characteristic (ROC) curve. This study will evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. The consensus of 2 experts may not be ideal as a "gold standard", and itself still requires further study. (No. ChiCTR-OOC-15006599).
Fast algorithm for probabilistic bone edge detection (FAPBED)
NASA Astrophysics Data System (ADS)
Scepanovic, Danilo; Kirshtein, Joshua; Jain, Ameet K.; Taylor, Russell H.
2005-04-01
The registration of preoperative CT to intra-operative reality systems is a crucial step in Computer Assisted Orthopedic Surgery (CAOS). The intra-operative sensors include 3D digitizers, fiducials, X-rays and Ultrasound (US). FAPBED is designed to process CT volumes for registration to tracked US data. Tracked US is advantageous because it is real time, noninvasive, and non-ionizing, but it is also known to have inherent inaccuracies which create the need to develop a framework that is robust to various uncertainties, and can be useful in US-CT registration. Furthermore, conventional registration methods depend on accurate and absolute segmentation. Our proposed probabilistic framework addresses the segmentation-registration duality, wherein exact segmentation is not a prerequisite to achieve accurate registration. In this paper, we develop a method for fast and automatic probabilistic bone surface (edge) detection in CT images. Various features that influence the likelihood of the surface at each spatial coordinate are combined using a simple probabilistic framework, which strikes a fair balance between a high-level understanding of features in an image and the low-level number crunching of standard image processing techniques. The algorithm evaluates different features for detecting the probability of a bone surface at each voxel, and compounds the results of these methods to yield a final, low-noise, probability map of bone surfaces in the volume. Such a probability map can then be used in conjunction with a similar map from tracked intra-operative US to achieve accurate registration. Eight sample pelvic CT scans were used to extract feature parameters and validate the final probability maps. An un-optimized fully automatic Matlab code runs in five minutes per CT volume on average, and was validated by comparison against hand-segmented gold standards. The mean probability assigned to nonzero surface points was 0.8, while nonzero non-surface points had a mean value of 0.38 indicating clear identification of surface points on average. The segmentation was also sufficiently crisp, with a full width at half maximum (FWHM) value of 1.51 voxels.
Robotic-assisted Heller myotomy: a modern technique and review of outcomes.
Afaneh, Cheguevara; Finnerty, Brendan; Abelson, Jonathan S; Zarnegar, Rasa
2015-06-01
Achalasia is a debilitating esophageal motility disorder characterized by incomplete relaxation of the lower esophageal sphincter and lack of peristalsis. Manometry is the gold standard for diagnosis and laparoscopic Heller myotomy has been the gold standard for definitive therapy. However, current advances in surgical technology have introduced the robotic platform as a viable approach for this procedure. The safety and efficacy has been clearly established with comparable operative times to laparoscopy in experienced hands. Importantly, the rate of resolution of dysphagia postoperatively is over 80% which is comparable to laparoscopic outcomes. Moreover, some literature suggests lower esophageal perforation rates utilizing the robotic platform. Nevertheless, costs remain one of the largest barriers to widespread use of the robotic platform and future studies should aim to identify strategies in cost reduction.
Reconsidering the H&E stain as the gold standard in assessing the depth of burn wounds.
Rosenberg, Arlene S
2017-12-01
While histological examination is considered by most as the gold standard for burn depth assessment, it has no practical use in the clinical setting. It has, however, been used in the research setting, as a mean for evaluating emerging techniques of depth measurement. Due to the limitations of the H&E stain, other stains have also been explored, such as lactate dehydrogenase (LDH), as presented in this issue, in "Improving the Histologic Characterization of Burn Depth." As the determination of burn depth is not a typical subject in dermatopathology, a summary of selected techniques and the possible role for the LDH stain in future research, is described herein. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Agreement, the F-Measure, and Reliability in Information Retrieval
Hripcsak, George; Rothschild, Adam S.
2005-01-01
Information retrieval studies that involve searching the Internet or marking phrases usually lack a well-defined number of negative cases. This prevents the use of traditional interrater reliability metrics like the κ statistic to assess the quality of expert-generated gold standards. Such studies often quantify system performance as precision, recall, and F-measure, or as agreement. It can be shown that the average F-measure among pairs of experts is numerically identical to the average positive specific agreement among experts and that κ approaches these measures as the number of negative cases grows large. Positive specific agreement—or the equivalent F-measure—may be an appropriate way to quantify interrater reliability and therefore to assess the reliability of a gold standard in these studies. PMID:15684123
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-21
... Formaldehyde; Third-Party Certification Framework for the Formaldehyde Standards for Composite Wood Products..., concerning a third-party certification framework for the formaldehyde standards for composite wood products... INFORMATION CONTACT. List of Subjects in 40 CFR Part 770 Environmental protection, Composite wood products...
Srisrattakarn, Arpasiri; Lulitanond, Aroonlug; Wilailuckana, Chotechana; Charoensri, Nicha; Daduang, Jureerut; Chanawong, Aroonwadee
2017-09-01
To develop a simple gold nanoparticle (AuNP)-based colorimetric test, GoldNano Carb (GoldC), for detecting carbapenemase production in Gram-negative bacteria, compared with updated Carba NP (CNP) and CarbAcineto NP (CAcNP) tests by using PCR methods as gold standard. Ninety-nine carbapenemase-producing Enterobacteriaceae (CPE), Pseudomonas spp. and Acinetobacter spp. isolates and 89 non-CPE isolates were tested by the GoldC and CNP. Additionally, the CAcNP was performed in the Acinetobacter spp. isolates. The final imipenem (imipenem/cilastatin form) concentration was 5 mg/mL for all three tests. For the GoldC, the imipenem powder was added directly to bacterial cell suspension in distilled water prior to detection of acid product by the citrate-capped AuNP solution. An AuNP change from red to purple, blue or green indicates carbapenemase activity. The GoldC detected all carbapenemase producers except one OXA-23-like producer (99.0% sensitivity), whereas 11 carbapenemase producers (10 Acinetobacter and 1 P. aeruginosa) were CNP negative (88.9% sensitivity). However, the GoldC and CNP provided 100% and 98.6% sensitivity, respectively, for the CPE and Pseudomonas spp. Both tests gave one false positive from CTX-M-1-like-producing Enterobacter spp. (98.9% specificity). The GoldC and CAcNP detected 96.7% and 93.3% of the Acinetobacter spp. isolates, respectively. Interestingly, times to positivity by the GoldC were markedly shorter than those by the CNP (76.8% versus 36.2% positive at 5 min) and CAcNP (43.3% at 5 min versus 20% within 30 min). The GoldC is fast, easy, highly sensitive and inexpensive (∼$0.25 per test), suggesting that it may be suitable for routine carbapenemase detection in low-resource settings for infection control or epidemiological purposes. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ganda, Erika Korzune; Bisinotto, Rafael Sisconeto; Decter, Dean Harrison; Bicalho, Rodrigo Carvalho
2016-01-01
The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538) was cultured on-farm using a single plate containing three selective chromogenic media (Accumast-FERA Animal Health LCC, Ithaca, NY) and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214). In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive value (NPV) were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively.
2011-01-01
Background Computerized Clinical Records, which are incorporated in primary health care practice, have great potential for research. In order to use this information, data quality and reliability must be assessed to prevent compromising the validity of the results. The aim of this study is to validate the diagnosis of hypertension and diabetes mellitus in the computerized clinical records of primary health care, taking the diagnosis criteria established in the most prominently used clinical guidelines as the gold standard against which what measure the sensitivity, specificity, and determine the predictive values. The gold standard for diabetes mellitus was the diagnostic criteria established in 2003 American Diabetes Association Consensus Statement for diabetic subjects. The gold standard for hypertension was the diagnostic criteria established in the Joint National Committee published in 2003. Methods A cross-sectional multicentre validation study of diabetes mellitus and hypertension diagnoses in computerized clinical records of primary health care was carried out. Diagnostic criteria from the most prominently clinical practice guidelines were considered for standard reference. Sensitivity, specificity, positive and negative predictive values, and global agreement (with kappa index), were calculated. Results were shown overall and stratified by sex and age groups. Results The agreement for diabetes mellitus with the reference standard as determined by the guideline was almost perfect (κ = 0.990), with a sensitivity of 99.53%, a specificity of 99.49%, a positive predictive value of 91.23% and a negative predictive value of 99.98%. Hypertension diagnosis showed substantial agreement with the reference standard as determined by the guideline (κ = 0.778), the sensitivity was 85.22%, the specificity 96.95%, the positive predictive value 85.24%, and the negative predictive value was 96.95%. Sensitivity results were worse in patients who also had diabetes and in those aged 70 years or over. Conclusions Our results substantiate the validity of using diagnoses of diabetes and hypertension found within the computerized clinical records for epidemiologic studies. PMID:22035202
Ganda, Erika Korzune; Bisinotto, Rafael Sisconeto; Decter, Dean Harrison; Bicalho, Rodrigo Carvalho
2016-01-01
The present study aimed evaluate an on-farm culture system for identification of milk pathogens associated with clinical mastitis in dairy cows using two different gold standard approaches: standard laboratory culture in study 1 and 16S rRNA sequencing in study 2. In study 1, milk from mastitic quarters (i.e. presence of flakes, clots, or serous milk; n = 538) was cultured on-farm using a single plate containing three selective chromogenic media (Accumast—FERA Animal Health LCC, Ithaca, NY) and in a reference laboratory using standard culture methods, which was considered the gold standard. In study 2, mastitic milk was cultured on-farm and analyzed through 16S rRNA sequencing (n = 214). In both studies, plates were cultured aerobically at 37°C for 24 h and read by a single technician masked to gold standard results. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive value (NPV) were calculated based on standard laboratory culture in study 1, and PPV was calculated based on sequencing results in study 2. Overall accuracy of Accumast was 84.9%. Likewise, accuracy for identification of Gram-negative bacteria, Staphylococcus sp., and Streptococcus sp. was 96.4%, 93.8%, and 91.5%, respectively. Sensitivity, specificity, PPV, and NPV were 75.0%, 97.9%, 79.6%, and 97.3% for identification of E. coli, 100.0%, 99.8%, 87.5%, and 100.0% for S. aureus, 70.0%, 95.0%, 45.7%, and 98.1% for other Staphylococcus sp., and 90.0%, 92.9%, 91.8%, and 91.2% for Streptococcus sp. In study 2, Accumast PPV was 96.7% for E. coli, 100.0% for Enterococcus sp., 100.0% for Other Gram-negatives, 88.2% for Staphylococcus sp., and 95.0% for Streptococcus sp., respectively. In conclusion, Accumast is a unique approach for on-farm identification pathogens associated with mastitis, presenting overall sensitivity and specificity of 82.3% and 89.9% respectively. PMID:27176216
The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
Saboury, Abolfazl; Neshandar Asli, Hamid; Dalili Kajan, Zahra
2017-01-01
Statement of the Problem: Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose: This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the cemented metal framework and the implant analog. Materials and Method: A definitive cast with two 15° mesially angulated implants served as the standard reference for making all the impressions and later for accuracy evaluation. Four groups of five samples were evaluated: (1) closed-tray snap-fit transfer, (2) open-tray nonsplinted impression coping, (3) metal splinted impression coping, and (4) fabricated acrylic resin transfer cap. A gold-palladium framework was fabricated over the angulated implant abutments, the fit of which was used as reference. The gaps between the metal framework and the implant analogs were measured in sample groups. Corresponding means for each technique and the definitive cast were compared by using ANOVA and post hoc tests. Results: The mean marginal gap was 38.16±0µm in definitive cast, 89±19.74µm in group 1, 78.66±20.63µm in group 2, 54.16±24.29µm in group 3, and 55.83±18.30µm in group 4. ANOVA revealed significant differences between the definitive cast and groups 1 and 2, but not with groups 3 and 4 (p< 0.05). Conclusion: Vertical gap measurements showed that metal splinted impression coping and fabricated acrylic resin transfer cap techniques produced quite more accurate impressions than closed-tray snap-fit transfer and open-tray nonsplinted impression coping techniques do. The fabricated acrylic resin transfer cap technique seems to be a reliable impression-making method. PMID:29201973
A Standardization Framework for Electronic Government Service Portals
NASA Astrophysics Data System (ADS)
Sarantis, Demetrios; Tsiakaliaris, Christos; Lampathaki, Fenareti; Charalabidis, Yannis
Although most eGovernment interoperability frameworks (eGIFs) cover adequately the technical aspects of developing and supporting the provision of electronic services to citizens and businesses, they do not exclusively address several important areas regarding the organization, presentation, accessibility and security of the content and the electronic services offered through government portals. This chapter extends the scope of existing eGIFs presenting the overall architecture and the basic concepts of the Greek standardization framework for electronic government service portals which, for the first time in Europe, is part of a country's eGovernment framework. The proposed standardization framework includes standards, guidelines and recommendations regarding the design, development and operation of government portals that support the provision of administrative information and services to citizens and businesses. By applying the guidelines of the framework, the design, development and operation of portals in central, regional and municipal government can be systematically addressed resulting in an applicable, sustainable and ever-expanding framework.
ERIC Educational Resources Information Center
Vermont Department of Education, 2004
2004-01-01
This document, "Grade Expectations for Vermont's Framework of Standards and Learning Opportunities" (hereafter "Vermont's Grade Expectations"), is an important companion to "Vermont's Framework." These Grade Expectations (GEs) serve the same purposes as "Vermont's Framework," but articulate learning…
Khatir, Nadia Mahmoudi; Banihashemian, Seyedeh Maryam; Periasamy, Vengadesh; Ritikos, Richard; Abd Majid, Wan Haliza; Abdul Rahman, Saadah
2012-01-01
This work presents an experimental study of gold-DNA-gold structures in the presence and absence of external magnetic fields with strengths less than 1,200.00 mT. The DNA strands, extracted by standard method were used to fabricate a Metal-DNA-Metal (MDM) structure. Its electric behavior when subjected to a magnetic field was studied through its current-voltage (I-V) curve. Acquisition of the I-V curve demonstrated that DNA as a semiconductor exhibits diode behavior in the MDM structure. The current versus magnetic field strength followed a decreasing trend because of a diminished mobility in the presence of a low magnetic field. This made clear that an externally imposed magnetic field would boost resistance of the MDM structure up to 1,000.00 mT and for higher magnetic field strengths we can observe an increase in potential barrier in MDM junction. The magnetic sensitivity indicates the promise of using MDM structures as potential magnetic sensors.
Brülle, Tine; Ju, Wenbo; Niedermayr, Philipp; Denisenko, Andrej; Paschos, Odysseas; Schneider, Oliver; Stimming, Ulrich
2011-12-06
Gold nanoparticles were prepared by electrochemical deposition on highly oriented pyrolytic graphite (HOPG) and boron-doped, epitaxial 100-oriented diamond layers. Using a potentiostatic double pulse technique, the average particle size was varied in the range from 5 nm to 30 nm in the case of HOPG as a support and between < 1 nm and 15 nm on diamond surfaces, while keeping the particle density constant. The distribution of particle sizes was very narrow, with standard deviations of around 20% on HOPG and around 30% on diamond. The electrocatalytic activity towards hydrogen evolution and oxygen reduction of these carbon supported gold nanoparticles in dependence of the particle sizes was investigated using cyclic voltammetry. For oxygen reduction the current density normalized to the gold surface (specific current density) increased for decreasing particle size. In contrast, the specific current density of hydrogen evolution showed no dependence on particle size. For both reactions, no effect of the different carbon supports on electrocatalytic activity was observed.
Khatir, Nadia Mahmoudi; Banihashemian, Seyedeh Maryam; Periasamy, Vengadesh; Ritikos, Richard; Majid, Wan Haliza Abd; Rahman, Saadah Abdul
2012-01-01
This work presents an experimental study of gold-DNA-gold structures in the presence and absence of external magnetic fields with strengths less than 1,200.00 mT. The DNA strands, extracted by standard method were used to fabricate a Metal-DNA-Metal (MDM) structure. Its electric behavior when subjected to a magnetic field was studied through its current-voltage (I–V) curve. Acquisition of the I–V curve demonstrated that DNA as a semiconductor exhibits diode behavior in the MDM structure. The current versus magnetic field strength followed a decreasing trend because of a diminished mobility in the presence of a low magnetic field. This made clear that an externally imposed magnetic field would boost resistance of the MDM structure up to 1,000.00 mT and for higher magnetic field strengths we can observe an increase in potential barrier in MDM junction. The magnetic sensitivity indicates the promise of using MDM structures as potential magnetic sensors. PMID:22737025
Fabrication and optical characterization of silica optical fibers containing gold nanoparticles.
de Oliveira, Rafael E P; Sjödin, Niclas; Fokine, Michael; Margulis, Walter; de Matos, Christiano J S; Norin, Lars
2015-01-14
Gold nanoparticles have been used since antiquity for the production of red-colored glasses. More recently, it was determined that this color is caused by plasmon resonance, which additionally increases the material's nonlinear optical response, allowing for the improvement of numerous optical devices. Interest in silica fibers containing gold nanoparticles has increased recently, aiming at the integration of nonlinear devices with conventional optical fibers. However, fabrication is challenging due to the high temperatures required for silica processing and fibers with gold nanoparticles were solely demonstrated using sol-gel techniques. We show a new fabrication technique based on standard preform/fiber fabrication methods, where nanoparticles are nucleated by heat in a furnace or by laser exposure with unprecedented control over particle size, concentration, and distribution. Plasmon absorption peaks exceeding 800 dB m(-1) at 514-536 nm wavelengths were observed, indicating higher achievable nanoparticle concentrations than previously reported. The measured resonant nonlinear refractive index, (6.75 ± 0.55) × 10(-15) m(2) W(-1), represents an improvement of >50×.
An Overview of the Clinical Use of Filter Paper in the Diagnosis of Tropical Diseases
Smit, Pieter W.; Elliott, Ivo; Peeling, Rosanna W.; Mabey, David; Newton, Paul N.
2014-01-01
Tropical infectious diseases diagnosis and surveillance are often hampered by difficulties of sample collection and transportation. Filter paper potentially provides a useful medium to help overcome such problems. We reviewed the literature on the use of filter paper, focusing on the evaluation of nucleic acid and serological assays for diagnosis of infectious diseases using dried blood spots (DBS) compared with recognized gold standards. We reviewed 296 eligible studies and included 101 studies evaluating DBS and 192 studies on other aspects of filter paper use. We also discuss the use of filter paper with other body fluids and for tropical veterinary medicine. In general, DBS perform with sensitivities and specificities similar or only slightly inferior to gold standard sample types. However, important problems were revealed with the uncritical use of DBS, inappropriate statistical analysis, and lack of standardized methodology. DBS have great potential to empower healthcare workers by making laboratory-based diagnostic tests more readily accessible, but additional and more rigorous research is needed. PMID:24366501
Quantized thermal transport in single-atom junctions
NASA Astrophysics Data System (ADS)
Cui, Longji; Jeong, Wonho; Hur, Sunghoon; Matt, Manuel; Klöckner, Jan C.; Pauly, Fabian; Nielaba, Peter; Cuevas, Juan Carlos; Meyhofer, Edgar; Reddy, Pramod
2017-03-01
Thermal transport in individual atomic junctions and chains is of great fundamental interest because of the distinctive quantum effects expected to arise in them. By using novel, custom-fabricated, picowatt-resolution calorimetric scanning probes, we measured the thermal conductance of gold and platinum metallic wires down to single-atom junctions. Our work reveals that the thermal conductance of gold single-atom junctions is quantized at room temperature and shows that the Wiedemann-Franz law relating thermal and electrical conductance is satisfied even in single-atom contacts. Furthermore, we quantitatively explain our experimental results within the Landauer framework for quantum thermal transport. The experimental techniques reported here will enable thermal transport studies in atomic and molecular chains, which will be key to investigating numerous fundamental issues that thus far have remained experimentally inaccessible.
Casting inorganic structures with DNA molds
Sun, Wei; Boulais, Etienne; Hakobyan, Yera; Wang, Wei Li; Guan, Amy; Bathe, Mark; Yin, Peng
2014-01-01
We report a general strategy for designing and synthesizing inorganic nanostructures with arbitrarily prescribed three-dimensional shapes. Computationally designed DNA strands self-assemble into a stiff “nano-mold” that contains a user-specified three-dimensional cavity and encloses a nucleating gold “seed”. Under mild conditions, this seed grows into a larger cast structure that fills and thus replicates the cavity. We synthesized a variety of nanoparticles with three nanometer resolution: three distinct silver cuboids with three independently tunable dimensions, silver and gold nanoparticles with diverse cross sections, and composite structures with homo-/heterogeneous components. The designer equilateral silver triangular and spherical nanoparticles exhibited plasmonic properties consistent with electromagnetism-based simulations. Our framework is generalizable to more complex geometries and diverse inorganic materials, offering a range of applications in biosensing, photonics, and nanoelectronics. PMID:25301973
Vibrations of single-crystal gold nanorods and nanowires
NASA Astrophysics Data System (ADS)
Saviot, L.
2018-04-01
The vibrations of gold nanowires and nanorods are investigated numerically in the framework of continuum elasticity using the Rayleigh-Ritz variational method. Special attention is paid to identify the vibrations relevant in Raman scattering experiments. A comprehensive description of the vibrations of nanorods is proposed by determining their symmetry, comparing with standing waves in the corresponding nanowires, and estimating their Raman intensity. The role of experimentally relevant parameters such as the anisotropic cubic lattice structure, the presence of faceted lateral surfaces, and the shape of the ends of the nanorods is evaluated. Elastic anisotropy is shown to play a significant role contrarily to the presence of facets. Localized vibrations are found for nanorods with flat ends. Their evolution as the shape of the ends is changed to half-spheres is discussed.
Tanev, Stoyan; Sun, Wenbo; Pond, James; Tuchin, Valery V; Zharov, Vladimir P
2009-09-01
The formulation of the finite-difference time-domain (FDTD) approach is presented in the framework of its potential applications to in-vivo flow cytometry based on light scattering. The consideration is focused on comparison of light scattering by a single biological cell alone in controlled refractive-index matching conditions and by cells labeled by gold nanoparticles. The optical schematics including phase contrast (OPCM) microscopy as a prospective modality for in-vivo flow cytometry is also analyzed. The validation of the FDTD approach for the simulation of flow cytometry may open up a new avenue in the development of advanced cytometric techniques based on scattering effects from nanoscale targets. 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Kamalakar, M Venkata; Prendergast, Úna; Kübel, Christian; Lemma, Tibebe; Dayen, Jean-François
2014-01-01
Summary We prepare and investigate two-dimensional (2D) single-layer arrays and multilayered networks of gold nanoparticles derivatized with conjugated hetero-aromatic molecules, i.e., S-(4-{[2,6-bipyrazol-1-yl)pyrid-4-yl]ethynyl}phenyl)thiolate (herein S-BPP), as capping ligands. These structures are fabricated by a combination of self-assembly and microcontact printing techniques, and are characterized by electron microscopy, UV–visible spectroscopy and Raman spectroscopy. Selective binding of the S-BPP molecules to the gold nanoparticles through Au–S bonds is found, with no evidence for the formation of N–Au bonds between the pyridine or pyrazole groups of BPP and the gold surface. Subtle, but significant shifts with temperature of specific Raman S-BPP modes are also observed. We attribute these to dynamic changes in the orientation and/or increased mobility of the molecules on the gold nanoparticle facets. As for their conductance, the temperature-dependence for S-BPP networks differs significantly from standard alkanethiol-capped networks, especially above 220 K. Relating the latter two observations, we propose that dynamic changes in the molecular layers effectively lower the molecular tunnel barrier for BPP-based arrays at higher temperatures. PMID:25383278
Devid, Edwin J; Martinho, Paulo N; Kamalakar, M Venkata; Prendergast, Úna; Kübel, Christian; Lemma, Tibebe; Dayen, Jean-François; Keyes, Tia E; Doudin, Bernard; Ruben, Mario; van der Molen, Sense Jan
2014-01-01
We prepare and investigate two-dimensional (2D) single-layer arrays and multilayered networks of gold nanoparticles derivatized with conjugated hetero-aromatic molecules, i.e., S-(4-{[2,6-bipyrazol-1-yl)pyrid-4-yl]ethynyl}phenyl)thiolate (herein S-BPP), as capping ligands. These structures are fabricated by a combination of self-assembly and microcontact printing techniques, and are characterized by electron microscopy, UV-visible spectroscopy and Raman spectroscopy. Selective binding of the S-BPP molecules to the gold nanoparticles through Au-S bonds is found, with no evidence for the formation of N-Au bonds between the pyridine or pyrazole groups of BPP and the gold surface. Subtle, but significant shifts with temperature of specific Raman S-BPP modes are also observed. We attribute these to dynamic changes in the orientation and/or increased mobility of the molecules on the gold nanoparticle facets. As for their conductance, the temperature-dependence for S-BPP networks differs significantly from standard alkanethiol-capped networks, especially above 220 K. Relating the latter two observations, we propose that dynamic changes in the molecular layers effectively lower the molecular tunnel barrier for BPP-based arrays at higher temperatures.
Plasmonic properties and enhanced fluorescence of gold and dye-doped silica nanoparticle aggregates
NASA Astrophysics Data System (ADS)
Green, Nathaniel Scott
The development of metal-enhanced fluorescence has prompted a great interest in augmenting the photophysical properties of fluorescent molecules with noble metal nanostructures. Our research efforts, outlined in this dissertation, focus on augmenting properties of fluorophores by conjugation with gold nanostructures. The project goals are split into two separate efforts; the enhancement in brightness of fluorophores and long distance non-radiative energy transfer between fluorophores. We believe that interacting dye-doped silica nanoparticles with gold nanoparticles can facilitate both of these phenomena. Our primary research interest is focused on optimizing brightness, as this goal should open a path to studying the second goal of non-radiative energy transfer. The two major challenges to this are constructing suitable nanomaterials and functionalizing them to promote plasmonically active complexes. The synthesis of dye-doped layered silica nanoparticles allows for control over the discrete location of the dye and a substrate that can be surface functionalized. Controlling the exact location of the dye is important to create a silica spacer, which promotes productive interactions with metal nanostructures. Furthermore, the synthesis of silica nanoparticles allows for various fluorophores to be studied in similar environments (removing solvent and other chemo-sensitive issues). Functionalizing the surface of silica nanoparticles allows control over the degree of silica and gold nanoparticle aggregation in solution. Heteroaggregation in solution is useful for producing well-aggregated clusters of many gold around a single silica nanoparticle. The dye-doped surface functionalized silica nanoparticles can than be mixed efficiently with gold nanomaterials. Aggregating multiple gold nanospheres around a single dye-doped silica nanoparticle can dramatically increase the fluorescent brightness of the sample via metal-enhanced fluorescence due to increase plasmonic scattering. Our aim is to promote heteroaggregation with functionalized silica nanoparticles while minimizing homoaggregation of silica-silica or gold-gold species. Reproducible production of multiple gold nanospheres about a dye-doped silica nanoparticle should lead to dramatic fluorescence brightness enhancements in solution. Gold nanorods can potentially be used to establish radiationless energy transfer between hetero dye-doped silica nanoparticles via gold nanorod plasmon mediated FRET by aggregating two different dye-doped silica nanoparticles preferentially at opposite ends of the nanorod. End-cap binding is accomplished by tuning the strength of gold binding ligands that functionalize the surface of the silica nanoparticles. The gold nanorod can then theoretically serve as a waveguide by employing the longitudinal plasmon as a non-radiative energy transfer agent between the two different fluorophores, giving rise to a new ultrafast signaling paradigm. Heteroaggregation of dye-doped silica nanoparticles and gold nanorods can be potentially employed to as nano waveguides. Construction and aggregation of functionalized silica and gold nano-materials provides an opportunity to advance the field of fluorescence. The synthesis of gold nano-particles allows control over their size and shape, which give rise to useful optical and electronic properties. Silica nanoparticles provide a framework allowing control over a requisite distance for increasing beneficial and deceasing non-radiative dye-metal interactions as well fluorophore protection. Our aim is to take advantage of fine-tuned synthetic control of functionalized nanomaterials to realize the great potential of solution based metal-enhanced fluorescence for future applications.
The value of body weight measurement to assess dehydration in children.
Pruvost, Isabelle; Dubos, François; Chazard, Emmanuel; Hue, Valérie; Duhamel, Alain; Martinot, Alain
2013-01-01
Dehydration secondary to gastroenteritis is one of the most common reasons for office visits and hospital admissions. The indicator most commonly used to estimate dehydration status is acute weight loss. Post-illness weight gain is considered as the gold-standard to determine the true level of dehydration and is widely used to estimate weight loss in research. To determine the value of post-illness weight gain as a gold standard for acute dehydration, we conducted a prospective cohort study in which 293 children, aged 1 month to 2 years, with acute diarrhea were followed for 7 days during a 3-year period. The main outcome measures were an accurate pre-illness weight (if available within 8 days before the diarrhea), post-illness weight, and theoretical weight (predicted from the child's individual growth chart). Post-illness weight was measured for 231 (79%) and both theoretical and post-illness weights were obtained for 111 (39%). Only 62 (21%) had an accurate pre-illness weight. The correlation between post-illness and theoretical weight was excellent (0.978), but bootstrapped linear regression analysis showed that post-illness weight underestimated theoretical weight by 0.48 kg (95% CI: 0.06-0.79, p<0.02). The mean difference in the fluid deficit calculated was 4.0% of body weight (95% CI: 3.2-4.7, p<0.0001). Theoretical weight overestimated accurate pre-illness weight by 0.21 kg (95% CI: 0.08-0.34, p = 0.002). Post-illness weight underestimated pre-illness weight by 0.19 kg (95% CI: 0.03-0.36, p = 0.02). The prevalence of 5% dehydration according to post-illness weight (21%) was significantly lower than the prevalence estimated by either theoretical weight (60%) or clinical assessment (66%, p<0.0001).These data suggest that post-illness weight is of little value as a gold standard to determine the true level of dehydration. The performance of dehydration signs or scales determined by using post-illness weight as a gold standard has to be reconsidered.
The Value of Body Weight Measurement to Assess Dehydration in Children
Pruvost, Isabelle; Dubos, François; Chazard, Emmanuel; Hue, Valérie; Duhamel, Alain; Martinot, Alain
2013-01-01
Dehydration secondary to gastroenteritis is one of the most common reasons for office visits and hospital admissions. The indicator most commonly used to estimate dehydration status is acute weight loss. Post-illness weight gain is considered as the gold-standard to determine the true level of dehydration and is widely used to estimate weight loss in research. To determine the value of post-illness weight gain as a gold standard for acute dehydration, we conducted a prospective cohort study in which 293 children, aged 1 month to 2 years, with acute diarrhea were followed for 7 days during a 3-year period. The main outcome measures were an accurate pre-illness weight (if available within 8 days before the diarrhea), post-illness weight, and theoretical weight (predicted from the child’s individual growth chart). Post-illness weight was measured for 231 (79%) and both theoretical and post-illness weights were obtained for 111 (39%). Only 62 (21%) had an accurate pre-illness weight. The correlation between post-illness and theoretical weight was excellent (0.978), but bootstrapped linear regression analysis showed that post-illness weight underestimated theoretical weight by 0.48 kg (95% CI: 0.06–0.79, p<0.02). The mean difference in the fluid deficit calculated was 4.0% of body weight (95% CI: 3.2–4.7, p<0.0001). Theoretical weight overestimated accurate pre-illness weight by 0.21 kg (95% CI: 0.08–0.34, p = 0.002). Post-illness weight underestimated pre-illness weight by 0.19 kg (95% CI: 0.03–0.36, p = 0.02). The prevalence of 5% dehydration according to post-illness weight (21%) was significantly lower than the prevalence estimated by either theoretical weight (60%) or clinical assessment (66%, p<0.0001).These data suggest that post-illness weight is of little value as a gold standard to determine the true level of dehydration. The performance of dehydration signs or scales determined by using post-illness weight as a gold standard has to be reconsidered. PMID:23383058
Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter
2016-01-01
Introduction A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Materials and methods Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. Results and discussion This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80–0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76–0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94–0.99) for the MC-PCR and 0.99 (95% PCI 0.99–1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997–1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. Conclusion The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83). PMID:26968153
Hielkema, Margriet; De Winter, Andrea F; Reijneveld, Sijmen A
2017-06-15
Family-centered care seems promising in preventive pediatrics, but evidence is lacking as to whether this type of care is also valid as a means to identify risks to infants' social-emotional development. We aimed to examine the validity of such a family-centered approach. We conducted a prospective cohort study. During routine well-child visits (2-15 months), Preventive Child Healthcare (PCH) professionals used a family-centered approach, assessing domains as parents' competence, role of the partner, social support, barriers within the care-giving context, and child's wellbeing for 2976 children as protective, indistinct or a risk. If, based on the overall assessment (the families were labeled as "cases", N = 87), an intervention was considered necessary, parents filled in validated questionnaires covering the aforementioned domains. These questionnaires served as gold standards. For each case, two controls, matched by child-age and gender, also filled in questionnaires (N = 172). We compared PCH professionals' assessments with the parent-reported gold standards. Moreover, we evaluated which domain mostly contributed to the overall assessment. Spearman's rank correlation coefficients between PCH professionals' assessments and gold standards were overall reasonable (Spearman's rho 0.17-0.39) except for the domain barriers within the care-giving context. Scores on gold standards were significantly higher when PCH assessments were rated as "at risk" (overall and per domain).We found reasonable to excellent agreement regarding the absence of risk factors (negative agreement rate: 0.40-0.98), but lower agreement regarding the presence of risk factors (positive agreement rate: 0.00-0.67). An "at risk" assessment for the domain Barriers or life events within the care-giving context contributed most to being overall at risk, i.e. a case, odds ratio 100.1, 95%-confidence interval: 22.6 - infinity. Findings partially support the convergent validity of a family-centered approach in well-child care to assess infants' social-emotional wellbeing and their developmental context. Agreement was reasonable to excellent regarding protective factors, but lower regarding risk factors. Netherlands Trialregister, NTR2681. Date of registration: 05-01-2011, URL: http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2681 .
Ivandini, Tribidasari A; Wicaksono, Wiyogo P; Saepudin, Endang; Rismetov, Bakhadir; Einaga, Yasuaki
2015-03-01
Anodic stripping voltammetry (ASV) of colloidal gold-nanoparticles (AuNPs) was investigated at boron-doped diamond (BDD) electrodes in 50 mM HClO4. A deposition time of 300 s at-0.2 V (vs. Ag/AgCl) was fixed as the condition for the ASV. The voltammograms showed oxidation peaks that could be attributed to the oxidation of gold. These oxidation peaks were then investigated for potential application in immunochromatographic strip tests for the selective and quantitative detection of melamine, in which AuNPs were used as the label for the antibody of melamine. Linear regression of the oxidation peak currents appeared in the concentration range from 0.05-0.6 μg/mL melamine standard, with an estimated LOD of 0.069 μg/mL and an average relative standard deviation of 8.0%. This indicated that the method could be considered as an alternative method for selective and quantitative immunochromatographic applications. The validity was examined by the measurements of melamine injected into milk samples, which showed good recovery percentages during the measurements. Copyright © 2014 Elsevier B.V. All rights reserved.
Toward an Educational View of Scaling: Sufficing Standard and Not a Gold Standard
ERIC Educational Resources Information Center
Hung, David; Lee, Shu-Shing; Wu, Longkai
2015-01-01
Educational innovations in Singapore have reached fruition. It is now important to consider different innovations and issues that enable innovations to scale and become widespread. This proposition paper outlines two views of scaling and its relation to education systems. We argue that a linear model used in the medical field stresses top-down…
Banks, Debbie
2014-10-01
The purpose of this paper is to discuss the importance of standard representational photography in clinical photography and its aid in maintaining the gold standard in the medical illustration profession. it is important that professionals are aware of potential threats to good practice with many areas identified in the article.
Learning What Works in ITS from Non-Traditional Randomized Controlled Trial Data
ERIC Educational Resources Information Center
Pardos, Zachary A.; Dailey, Matthew D.; Heffernan, Neil T.
2011-01-01
The well established, gold standard approach to finding out what works in education research is to run a randomized controlled trial (RCT) using a standard pre-test and post-test design. RCTs have been used in the intelligent tutoring community for decades to determine which questions and tutorial feedback work best. Practically speaking, however,…
Preparation of calibrated test packages for particle impact noise detection
NASA Technical Reports Server (NTRS)
1977-01-01
A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.
Robotic assisted kidney transplantation
Modi, Pranjal; Pal, Bipinchandra; Modi, Jayesh; Kumar, Suresh; Sood, Akshay; Menon, Mani
2014-01-01
Kidney transplantation is the standard of care for patients with end stage renal disease. While open surgery remains the gold standard, minimally invasive surgery has recently been introduced for the recipient undergoing kidney transplantation. We review the evolution of techniques of minimally invasive surgery for kidney transplantation with specific emphasis on technical aspects of robotic assisted kidney transplantation. PMID:25097315
NASA Astrophysics Data System (ADS)
Della Ventura, B.; Funari, R.; Anoop, K. K.; Amoruso, S.; Ausanio, G.; Gesuele, F.; Velotta, R.; Altucci, C.
2015-06-01
We report an application of femtosecond laser ablation to improve the sensitivity of biosensors based on a quartz crystal microbalance device. The nanoparticles produced by irradiating a gold target with 527-nm, 300-fs laser pulses, in high vacuum, are directly deposited on the quartz crystal microbalance electrode. Different gold electrodes are fabricated by varying the deposition time, thus addressing how the nanoparticles surface coverage influences the sensor response. The modified biosensor is tested by weighting immobilized IgG antibody from goat and its analyte (IgG from mouse), and the results are compared with a standard electrode. A substantial increase of biosensor sensitivity is achieved, thus demonstrating that femtosecond laser ablation and deposition is a viable physical method to improve the biosensor sensitivity by means of nanostructured electrodes.
NASA Astrophysics Data System (ADS)
Yu, An; Geng, Tingting; Fu, Qiang; Chen, Chao; Cui, Yali
2007-04-01
Using GoldMag (Fe3O4/Au) nanoparticles as a carrier, a biotin-avidin amplified ELISA was developed to detect hepatitis B surface antigen (HBsAg). A specific antibody was labeled with biotin and then used to detect the antigen with an antibody coated on GoldMag nanoparticles by a sandwich ELISA assay. The results showed that 5 mol of biotin were surface bound per mole of antibody. The biotin-avidin amplified ELISA assay has a higher sensitivity than that of the direct ELISA assay. There is 5-fold difference between HBsAg positive and negative serum even at dilution of 1:10000, and the relative standard deviation of the parallel positive serum at dilution of 1:4000 is 5.98% (n=11).
Kazemi, Elahe; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad
2015-08-15
A selective, simple and rapid dispersive solid phase microextraction was developed using magnetic graphene oxide (MGO) as an efficient sorbent for the separation and preconcentration of gold ions. The MGO was synthesized by means of the simple one step chemical coprecipitation method, characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). Gold ions retained by the sorbent were eluted using 0.5mol L(-)(1) thiourea in 0.1mol L(-1) HCl solution and determined by the flow injection flame atomic absorption spectrometry (FI-FAAS). The factors affecting the separation and preconcentration of gold were investigated and optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 0.02-100.0µg L(-)(1) with a detection limit of 4ng L(-1) and an enrichment factor of 500. The relative standard deviations of 3.2% and 4.7% (n=6) were obtained at 20µg L(-1) level of gold ions for the intra and the inter day analysis, respectively. The method was successfully applied to the determination of gold ions in water and waste water samples as well as a certified reference material (CCU-1b, copper flotation concentrate). Copyright © 2015 Elsevier B.V. All rights reserved.
Image classification of unlabeled malaria parasites in red blood cells.
Zheng Zhang; Ong, L L Sharon; Kong Fang; Matthew, Athul; Dauwels, Justin; Ming Dao; Asada, Harry
2016-08-01
This paper presents a method to detect unlabeled malaria parasites in red blood cells. The current "gold standard" for malaria diagnosis is microscopic examination of thick blood smear, a time consuming process requiring extensive training. Our goal is to develop an automate process to identify malaria infected red blood cells. Major issues in automated analysis of microscopy images of unstained blood smears include overlapping cells and oddly shaped cells. Our approach creates robust templates to detect infected and uninfected red cells. Histogram of Oriented Gradients (HOGs) features are extracted from templates and used to train a classifier offline. Next, the ViolaJones object detection framework is applied to detect infected and uninfected red cells and the image background. Results show our approach out-performs classification approaches with PCA features by 50% and cell detection algorithms applying Hough transforms by 24%. Majority of related work are designed to automatically detect stained parasites in blood smears where the cells are fixed. Although it is more challenging to design algorithms for unstained parasites, our methods will allow analysis of parasite progression in live cells under different drug treatments.
Plant Genome Size Research: A Field In Focus
BENNETT, M. D.; LEITCH, I. J.
2005-01-01
This Special Issue contains 18 papers arising from presentations at the Second Plant Genome Size Workshop and Discussion Meeting (hosted by the Royal Botanic Gardens, Kew, 8–12 September, 2003). This preface provides an overview of these papers, setting their key contents in the broad framework of this highly active field. It also highlights a few overarching issues with wide biological impact or interest, including (1) the need to unify terminology relating to C-value and genome size, (2) the ongoing quest for accurate gold standards for accurate plant genome size estimation, (3) how knowledge of species' DNA amounts has increased in recent years, (4) the existence, causes and significance of intraspecific variation, (5) recent progress in understanding the mechanisms and evolutionary patterns of genome size change, and (6) the impact of genome size knowledge on related biological activities such as genetic fingerprinting and quantitative genetics. The paper offers a vision of how increased knowledge and understanding of genome size will contribute to holisitic genomic studies in both plants and animals in the next decade. PMID:15596455
Levecke, Bruno; Anderson, Roy M; Berkvens, Dirk; Charlier, Johannes; Devleesschauwer, Brecht; Speybroeck, Niko; Vercruysse, Jozef; Van Aelst, Stefan
2015-03-01
In the present study, we present a hierarchical model based on faecal egg counts (FECs; expressed in eggs per 1g of stool) in which we first describe the variation in FECs between individuals in a particular population, followed by describing the variance due to counting eggs under a microscope separately for each stool sample. From this general framework, we discuss how to calculate a sample size for assessing a population mean FEC and the impact of an intervention, measured as reduction in FECs, for any scenario of soil-transmitted helminth (STH) epidemiology (the intensity and aggregation of FECs within a population) and diagnostic strategy (amount of stool examined (∼sensitivity of the diagnostic technique) and examination of individual/pooled stool samples) and on how to estimate prevalence of STH in the absence of a gold standard. To give these applications the most wide relevance as possible, we illustrate each of them with hypothetical examples. Copyright © 2015 Elsevier Ltd. All rights reserved.
How children remember the Strange Situation: The role of attachment.
Chae, Yoojin; Goodman, Miranda; Goodman, Gail S; Troxel, Natalie; McWilliams, Kelly; Thompson, Ross A; Shaver, Phillip R; Widaman, Keith F
2018-02-01
This study tested predictions from Bowlby's attachment theory about children's memory and suggestibility. Young children (3-5years old, N=88; 76% Caucasians) and their parents took part in the Strange Situation Procedure, a moderately distressing event and "gold standard" for assessing children's attachment quality. The children were then interviewed about what occurred during the event. Children's age and attachment security scores positively predicted correct information in free recall and accuracy in answering specific questions. For children with higher (vs. lower) attachment security scores, greater distress observed during the Strange Situation Procedure predicted increased resistance to misleading suggestions. In addition, for children who displayed relatively low distress during the Strange Situation Procedure, significant age differences in memory and suggestibility emerged as expected. However, for children who displayed greater distress during the Strange Situation Procedure, younger and older children's memory performances were equivalent. Findings suggest that attachment theory provides an important framework for understanding facets of memory development with respect to attachment-related information and that distress may alter assumed age patterns in memory development. Copyright © 2017 Elsevier Inc. All rights reserved.
Sidibé, Cheick Abou Kounta; Grosbois, Vladimir; Thiaucourt, François; Niang, Mamadou; Lesnoff, Matthieu; Roger, François
2012-08-01
A Bayesian approach, allowing for conditional dependence between two tests was used to estimate without gold standard the sensitivities of complement fixation test (CFT) and competitive enzyme-linked immunosorbent assay test (cELISA) and the serological prevalence of CBPP in a cattle population of the Central Delta of the Niger River in Mali, where CBPP is enzootic and the true prevalence and animals serological state were unknown. A significant difference (P = 0.99) was observed between the sensitivities of the two tests, estimated at 73.7% (95% probability interval [PI], 63.4-82.7) for cELISA and 42.3% (95% PI, 33.3-53.7) for CFT. Individual-level serological prevalence in the study population was estimated at 14.1% (95% PI, 10.8-16.9). Our results indicate that in enzootic areas, cELISA performs better in terms of sensitivity than CFT. However, negative conditional sensitivity dependence between the two tests was detected, implying that to achieve maximum sensitivity, the two tests should be applied in parallel.
NASA Astrophysics Data System (ADS)
Unger, Jakob; Sun, Tianchen; Chen, Yi-Ling; Phipps, Jennifer E.; Bold, Richard J.; Darrow, Morgan A.; Ma, Kwan-Liu; Marcu, Laura
2018-01-01
An important step in establishing the diagnostic potential for emerging optical imaging techniques is accurate registration between imaging data and the corresponding tissue histopathology typically used as gold standard in clinical diagnostics. We present a method to precisely register data acquired with a point-scanning spectroscopic imaging technique from fresh surgical tissue specimen blocks with corresponding histological sections. Using a visible aiming beam to augment point-scanning multispectral time-resolved fluorescence spectroscopy on video images, we evaluate two different markers for the registration with histology: fiducial markers using a 405-nm CW laser and the tissue block's outer shape characteristics. We compare the registration performance with benchmark methods using either the fiducial markers or the outer shape characteristics alone to a hybrid method using both feature types. The hybrid method was found to perform best reaching an average error of 0.78±0.67 mm. This method provides a profound framework to validate diagnostical abilities of optical fiber-based techniques and furthermore enables the application of supervised machine learning techniques to automate tissue characterization.
Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula
Sierraalta, Marianella; Vivas, Jose L.; Razzoog, Michael E.; Wang, Rui-Feng
2012-01-01
Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to that of conventional cast frameworks. Material and Methods. Fifteen casts fabricated from a single edentulous CAD/CAM surgical guide were separated in two groups and resin patterns simulating the framework for a fixed complete denture developed. Five casts were sent to dental laboratories to invest, cast in a Palladium-Gold alloy and fit the framework. Ten casts had the resin pattern scanned for fabrication of milled bars in Titanium. Using measuring software, positions of implant replicas in the definitive model were recorded. The three dimensional spatial orientation of each implant replica was matched to the implant replica. Results. Results demonstrated the mean vertical gap of the Cast framework was 0.021 (+0.004) mm and 0.012 (0.002) mm determined by fixed and unfixed best-fit matching coordinate system. For Titanium frameworks they were 0.0037 (+0.0028) mm and 0.0024 (+0.0005) mm, respectively. Conclusions. Milled one-piece Titanium fixed complete denture frameworks provided a more accurate precision of fit then traditional cast frameworks. PMID:22550486
Garrett, Natalie L; Sekine, Ryo; Dixon, Matthew W A; Tilley, Leann; Bambery, Keith R; Wood, Bayden R
2015-09-07
Surface enhanced Raman scattering (SERS) is a powerful tool with great potential to provide improved bio-sensing capabilities. The current 'gold-standard' method for diagnosis of malaria involves visual inspection of blood smears using light microscopy, which is time consuming and can prevent early diagnosis of the disease. We present a novel surface-enhanced Raman spectroscopy substrate based on gold-coated butterfly wings, which enabled detection of malarial hemozoin pigment within lysed blood samples containing 0.005% and 0.0005% infected red blood cells.
The SGML Standardization Framework and the Introduction of XML
Grütter, Rolf
2000-01-01
Extensible Markup Language (XML) is on its way to becoming a global standard for the representation, exchange, and presentation of information on the World Wide Web (WWW). More than that, XML is creating a standardization framework, in terms of an open network of meta-standards and mediators that allows for the definition of further conventions and agreements in specific business domains. Such an approach is particularly needed in the healthcare domain; XML promises to especially suit the particularities of patient records and their lifelong storage, retrieval, and exchange. At a time when change rather than steadiness is becoming the faithful feature of our society, standardization frameworks which support a diversified growth of specifications that are appropriate to the actual needs of the users are becoming more and more important; and efforts should be made to encourage this new attempt at standardization to grow in a fruitful direction. Thus, the introduction of XML reflects a standardization process which is neither exclusively based on an acknowledged standardization authority, nor a pure market standard. Instead, a consortium of companies, academic institutions, and public bodies has agreed on a common recommendation based on an existing standardization framework. The consortium's process of agreeing to a standardization framework will doubtlessly be successful in the case of XML, and it is suggested that it should be considered as a generic model for standardization processes in the future. PMID:11720931
The SGML standardization framework and the introduction of XML.
Fierz, W; Grütter, R
2000-01-01
Extensible Markup Language (XML) is on its way to becoming a global standard for the representation, exchange, and presentation of information on the World Wide Web (WWW). More than that, XML is creating a standardization framework, in terms of an open network of meta-standards and mediators that allows for the definition of further conventions and agreements in specific business domains. Such an approach is particularly needed in the healthcare domain; XML promises to especially suit the particularities of patient records and their lifelong storage, retrieval, and exchange. At a time when change rather than steadiness is becoming the faithful feature of our society, standardization frameworks which support a diversified growth of specifications that are appropriate to the actual needs of the users are becoming more and more important; and efforts should be made to encourage this new attempt at standardization to grow in a fruitful direction. Thus, the introduction of XML reflects a standardization process which is neither exclusively based on an acknowledged standardization authority, nor a pure market standard. Instead, a consortium of companies, academic institutions, and public bodies has agreed on a common recommendation based on an existing standardization framework. The consortium's process of agreeing to a standardization framework will doubtlessly be successful in the case of XML, and it is suggested that it should be considered as a generic model for standardization processes in the future.
Finishing Using Next Generation Technologies
Van Tonder, Andries
2018-01-16
Andries van Tonder of Wellcome Trust Sanger Institute discusses a pipeline for finishing genomes to the gold standard on June 3, 2010 at the "Sequencing, Finishing, Analysis in the Future" meeting in Santa Fe, NM.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Affordable Care Act; and (3) A bronze, silver, gold, or platinum level of coverage as described in section....103 of this subtitle. Level of coverage means one of four standardized actuarial values as defined by...
Letter from the Friends Chairman
... additional copies of the publication. That is exactly the kind of response we hoped to receive. We have one goal—to provide you with a gold standard of reliable, understandable and up-to-date health ...
40 CFR 440.148 - Best Management Practices (BMP).
Code of Federal Regulations, 2013 CFR
2013-07-01
... GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE CATEGORY Gold Placer Mine... control: The amount of new water allowed to enter the plant site for use in ore processing shall be...
40 CFR 440.148 - Best Management Practices (BMP).
Code of Federal Regulations, 2012 CFR
2012-07-01
... GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE CATEGORY Gold Placer Mine... control: The amount of new water allowed to enter the plant site for use in ore processing shall be...
40 CFR 440.148 - Best Management Practices (BMP).
Code of Federal Regulations, 2014 CFR
2014-07-01
... GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE CATEGORY Gold Placer Mine... control: The amount of new water allowed to enter the plant site for use in ore processing shall be...
Creating a Gold Standard for the Readability Measurement of Health Texts
Kandula, Sasikiran; Zeng-Treitler, Qing
2008-01-01
Developing easy-to-read health texts for consumers continues to be a challenge in health communication. Though readability formulae such as Flesch-Kincaid Grade Level have been used in many studies, they were found to be inadequate to estimate the difficulty of some types of health texts. One impediment to the development of new readability assessment techniques is the absence of a gold standard that can be used to validate them. To overcome this deficiency, we have compiled a corpus of 324 health documents consisting of six different types of texts. These documents were manually reviewed and assigned a readability level (1-7 Likert scale) by a panel of five health literacy experts. The expert assigned ratings were found to be highly correlated with a patient representative’s readability ratings (r = 0.81, p<0.0001). PMID:18999150
Hailu, Tadesse; Abera, Bayeh
2015-07-01
The parasite load within the sample and the amount of sample taken during examination greatly compromise the sensitivity of direct saline stool microscopy. A cross-sectional study was conducted in March 2011 in Bahir Dar city among 778 fresh single stool samples to evaluate the performance of direct saline (DS), Kato Katz (KK) and Formol ether concentration (FEC) methods against the 'Gold' standard. Among 778 stool samples from school age children, the highest prevalence of intestinal parasites was recorded by FEC (55.1%). The sensitivity of DS, FEC and KK were 61.1%, 92.3% and 58.7%, respectively. FEC is more sensitive than DS and KK. Hence, use of the latter is preferred. © The Author(s) 2015.
NASA Astrophysics Data System (ADS)
Richards-Kortum, Rebecca
2016-03-01
Esophageal squamous cell neoplasia (ESCN) is the sixth leading cause of cancer death worldwide. Most deaths due to ESCN occur in developing countries, with highest risk areas in northern China. Lugol's chromoendoscopy (LCE) is the gold-standard for ESCN screening; while the sensitivity of LCE for ESCN is >95%, LCE suffers poor specificity (< 65%) due to false positive findings from inflammatory lesions. High resolution microendoscopy (HRME) uses a low-cost, fiber-optic fluorescence microscope to image morphology of the surface epithelium without need for biopsy. We developed a tablet-interfaced HRME with automated, real-time image analysis. In an in vivo study of 177 patients referred for endoscopy in China, use of the algorithm identified neoplasia with a sensitivity and specificity of 95% and 91% compared to the gold standard of histology.
Balance and Gait Impairment: Sensor-Based Assessment for Patients With Peripheral Neuropathy.
Campbell, Grace; Skubic, Marjorie A
2018-06-01
Individuals with peripheral neuropathy (PN) frequently experience balance and gait impairments that can lead to poor physical function, falls, and injury. Nurses are aware that patients with cancer experience balance and gait impairments but are unsure of optimal assessment and management strategies. This article reviews options for balance and gait assessment for patients diagnosed with cancer experiencing PN, describes advantages and limitations of the various options, and highlights innovative, clinically feasible technologies to improve clinical assessment and management. The literature was reviewed to identify and assess the gold standard quantitative measures for assessing balance and gait. Gold standard quantitative measures are burdensome for patients and not often used in clinical practice. Sensor-based technologies improve balance and gait assessment options by calculating precise impairment measures during performance of simple clinical tests at the point of care.
Beekman, Emmylou; Theunissen, Kyra; Braun, Susy; Beurskens, Anna J
2018-01-01
Background Measuring physical activity with commercially available activity trackers is gaining popularity. People with a chronic disease can especially benefit from knowledge about their physical activity pattern in everyday life since sufficient physical activity can contribute to wellbeing and quality of life. However, no validity data are available for this population during activities of daily living. Objective The aim of this study was to investigate the validity of 9 commercially available activity trackers for measuring step count during activities of daily living in people with a chronic disease receiving physiotherapy. Methods The selected activity trackers were Accupedo (Corusen LLC), Activ8 (Remedy Distribution Ltd), Digi-Walker CW-700 (Yamax), Fitbit Flex (Fitbit inc), Lumoback (Lumo Bodytech), Moves (ProtoGeo Oy), Fitbit One (Fitbit inc), UP24 (Jawbone), and Walking Style X (Omron Healthcare Europe BV). In total, 130 persons with chronic diseases performed standardized activity protocols based on activities of daily living that were recorded on video camera and analyzed for step count (gold standard). The validity of the trackers’ step count was assessed by correlation coefficients, t tests, scatterplots, and Bland-Altman plots. Results The correlations between the number of steps counted by the activity trackers and the gold standard were low (range: –.02 to .33). For all activity trackers except for Fitbit One, a significant systematic difference with the gold standard was found for step count. Plots showed a wide range in scores for all activity trackers; Activ8 showed an average overestimation and the other 8 trackers showed underestimations. Conclusions This study showed that the validity of 9 commercially available activity trackers is low measuring steps while individuals with chronic diseases receiving physiotherapy engage in activities of daily living. PMID:29610110
Signori, Cácia; Collares, Kauê; Cumerlato, Catarina B F; Correa, Marcos B; Opdam, Niek J M; Cenci, Maximiliano S
2018-04-01
The aim of this study was to investigate the validity of assessment of intraoral digital photography in the evaluation of dental restorations. Intraoral photographs of anterior and posterior restorations were classified based on FDI criteria according to the need for intervention: no intervention, repair and replacement. Evaluations were performed by an experienced expert in restorative dentistry (gold standard evaluator) and 3 trained dentists (consensus). The clinical inspection was the reference standard method. The prevalence of failures was explored. Cohen's kappa statistic was used. Validity was accessed by sensitivity, specificity, likelihood ratio and predictives values. Higher prevalence of failed restorations intervention was identified by the intraoral photography (17.7%) in comparison to the clinical evaluation (14.1%). Moderate agreement in the diagnosis of total failures was shown between the methods for the gold standard evaluator (kappa = 0.51) and consensus of evaluators (kappa = 0.53). Gold standard evaluator and consensus showed substantial and moderate agreement for posterior restorations (kappa = 0.61; 0.59), and fair and moderate agreement for anterior restorations (kappa = 0.36; 0.43), respectively. The accuracy was 84.8% in the assessment by intraoral photographs. Sensitivity and specificity values of 87.5% and 89.3% were found. Under the limits of this study, the assessment of digital photography performed by intraoral camera is an indirect diagnostic method valid for the evaluation of dental restorations, mainly in posterior teeth. This method should be employed taking into account the higher detection of defects provided by the images, which are not always clinically relevant. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ni, Yizhao; Kennebeck, Stephanie; Dexheimer, Judith W; McAneney, Constance M; Tang, Huaxiu; Lingren, Todd; Li, Qi; Zhai, Haijun; Solti, Imre
2015-01-01
Objectives (1) To develop an automated eligibility screening (ES) approach for clinical trials in an urban tertiary care pediatric emergency department (ED); (2) to assess the effectiveness of natural language processing (NLP), information extraction (IE), and machine learning (ML) techniques on real-world clinical data and trials. Data and methods We collected eligibility criteria for 13 randomly selected, disease-specific clinical trials actively enrolling patients between January 1, 2010 and August 31, 2012. In parallel, we retrospectively selected data fields including demographics, laboratory data, and clinical notes from the electronic health record (EHR) to represent profiles of all 202795 patients visiting the ED during the same period. Leveraging NLP, IE, and ML technologies, the automated ES algorithms identified patients whose profiles matched the trial criteria to reduce the pool of candidates for staff screening. The performance was validated on both a physician-generated gold standard of trial–patient matches and a reference standard of historical trial–patient enrollment decisions, where workload, mean average precision (MAP), and recall were assessed. Results Compared with the case without automation, the workload with automated ES was reduced by 92% on the gold standard set, with a MAP of 62.9%. The automated ES achieved a 450% increase in trial screening efficiency. The findings on the gold standard set were confirmed by large-scale evaluation on the reference set of trial–patient matches. Discussion and conclusion By exploiting the text of trial criteria and the content of EHRs, we demonstrated that NLP-, IE-, and ML-based automated ES could successfully identify patients for clinical trials. PMID:25030032
Neves, Frederico S; Vasconcelos, Taruska V; Campos, Paulo S F; Haiter-Neto, Francisco; Freitas, Deborah Q
2014-02-01
The aim of this study was to evaluate the effect of scan mode of the cone beam computed tomography (CBCT) in the preoperative dental implant measurements. Completely edentulous mandibles with entirely resorbed alveolar processes were selected for this study. Five regions were selected (incisor, canine, premolar, first molar, and second molar). The mandibles were scanned with Next Generation i-CAT CBCT unit (Imaging Sciences International, Inc, Hatfield, PA, USA) with half (180°) and full (360°) mode. Two oral radiologists performed vertical measurements in all selected regions; the measurements of half of the sample were repeated within an interval of 30 days. The mandibles were sectioned using an electrical saw in all evaluated regions to obtain the gold standard. The intraclass correlation coefficient was calculated for the intra- and interobserver agreement. Descriptive statistics were calculated as mean, median, and standard deviation. Wilcoxon signed rank test was used to determine the correlation between the measurements obtained in different scan mode with the gold standard. The significance level was 5%. The values of intra- and interobserver reproducibility indicated a strong agreement. In the dental implant measurements, except the bone height of the second molar region in full scan mode (P = 0.02), the Wilcoxon signed rank test did not show statistical significant difference with the gold standard (P > 0.05). Both modes provided real measures, necessary when performing implant planning; however, half scan mode uses smaller doses, following the principle of effectiveness. We believe that this method should be used because of the best dose-effect relationship and offer less risk to the patient. © 2012 John Wiley & Sons A/S.
Boccardi, Marina; Festari, Cristina; Altomare, Daniele; Gandolfo, Federica; Orini, Stefania; Nobili, Flavio; Frisoni, Giovanni B
2018-04-30
FDG-PET is frequently used as a marker of synaptic damage to diagnose dementing neurodegenerative disorders. We aimed to adapt the items of evidence quality to FDG-PET diagnostic studies, and assess the evidence available in current literature to assist Delphi decisions for European recommendations for clinical use. Based on acknowledged methodological guidance, we defined the domains, specific to FDG-PET, required to assess the quality of evidence in 21 literature searches addressing as many Population Intervention Comparison Outcome (PICO) questions. We ranked findings for each PICO and fed experts making Delphi decisions for recommending clinical use. Among the 1435 retrieved studies, most lacked validated measures of test performance, an adequate gold standard, and head-to-head comparison of FDG-PET and clinical diagnosis, and only 58 entered detailed assessment. Only two studies assessed the accuracy of the comparator (clinical diagnosis) versus any kind of gold-/reference-standard. As to the index-test (FDG-PET-based diagnosis), an independent gold-standard was available in 24% of the examined papers; 38% used an acceptable reference-standard (clinical follow-up); and 38% compared FDG-PET-based diagnosis only to baseline clinical diagnosis. These methodological limitations did not allow for deriving recommendations from evidence. An incremental diagnostic value of FDG-PET versus clinical diagnosis or lack thereof cannot be derived from the current literature. Many of the observed limitations may easily be overcome, and we outlined them as research priorities to improve the quality of current evidence. Such improvement is necessary to outline evidence-based guidelines. The available data were anyway provided to expert clinicians who defined interim recommendations.
Validation of a telephone screening tool for spasmodic dysphonia and vocal fold tremor.
Johnson, David M; Hapner, Edie R; Klein, Adam M; Pethan, Madeleine; Johns, Michael M
2014-11-01
The objective of this study was to ascertain whether clinicians can reliably distinguish between spasmodic dysphonia (SD)/vocal tremor and other voice disorders by telephone, despite this modality's limited frequency response. Randomized, single-blinded, and prospective study. Voice-disordered patients with (n = 22) and without (n = 17) SD and/or vocal tremor recorded standardized utterances via landline telephone. A laryngologist and two speech-language pathologists blinded to the diagnoses rated each recording as "yes" or "no" to "SD or tremor present?," and if "yes" categorized into adductor, abductor, tremor only, or adductor with tremor subtypes. Twenty-one recordings were presented twice at random so intrarater reliability could be assessed. All ratings were compared with gold standard diagnosis by a second laryngologist who performed a full examination, including videostroboscopy, on each patient. For the comparison "SD or tremor" yes versus no, sensitivity, specificity, positive predictive value, and negative predictive value are 90%, 95%, 96%, and 89%, respectively. Interrater reliability (Cohen kappa) compared with the gold standard ranged from 0.70 to 0.93 (substantial to almost perfect agreement). Cronbach alpha among three raters was 0.90 for this comparison. Intrarater reliability (number matched/number inspected) was very high, ranging from 0.97 to 1.0. Comparing gold standard and telephone rating of SD/tremor subtypes, kappa ranged from 0.48 to 0.60 (moderate agreement). Cronbach alpha among three raters was 0.88 for this comparison. Intrarater reliability ranged from 0.84 to 0.97. SD and tremor can be reliably distinguished from other voice disorders over the telephone. Copyright © 2014 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Teresi, Jeanne A; Grober, Ellen; Eimicke, Joseph P; Ehrlich, Amy R
2012-09-01
A randomized controlled trial examined whether the diagnostic process for Alzheimer's disease and other dementias may be influenced by knowledge of the patient's education and/or self-reported race. Four conditions were implemented: diagnostic team knows (a) race and education, (b) education only, (c) race only, or (d) neither. Diagnosis and clinical staging was established at baseline, at Wave 2, and for a random sample of Wave 3 respondents by a consensus panel. At study end, a longitudinal, "gold standard" diagnosis was made for patients with follow-up data (71%). Group differences in Diagnostic and Statistical Manual of Mental Disorders (4th ed.; American Psychiatric Association, 1994) diagnosis were estimated using logistic regression and generalized estimating equations. Sensitivity and specificity were examined for baseline diagnosis in relation to the gold standard, longitudinal diagnosis. Despite equivalent status on all measured variables across waves, members of the "knows race only" group were less likely than those of other groups to receive a diagnosis of dementia. At final diagnosis, 19% of the "knows race only" group was diagnosed with dementia versus 38% to 40% in the other 3 conditions (p = .038). Examination of sensitivities and specificities of baseline diagnosis in relation to the gold standard diagnosis showed a nonsignificant trend for lower sensitivities in the knowing race conditions (0.3846), as contrasted with knowing education only (0.480) or neither (0.600). The finding that knowledge of race may influence the diagnostic process in some unknown way is timely, given the recent State-of-the-Science conference on Alzheimer's disease prevention, the authors of which called for information about and standardization of the diagnostic process. PsycINFO Database Record (c) 2012 APA, all rights reserved.
Zhou, Yuan; Zhou, Tao; Zhou, Rui; Hu, Yonggang
2014-06-01
A rapid, simple, facile, sensitive and enzyme-amplified chemiluminescence immunoassay (CLIA) method to detect antibodies against porcine parvovirus has been developed. Horseradish peroxidase (HRP) and the detection antibody were simultaneously co-immobilized on the surface of gold nanoparticles using the electrostatic method to form gold nanoparticle-based nanoprobes. This nanoprobe was employed in a sandwich-type CLIA, which enables CL signal readout from enzymatic catalysis and results in signal amplification. The presence of porcine parvovirus infection was determined in porcine parvovirus antibodies by measuring the CL intensity caused by the reaction of HRP-luminol with H2 O2 . Under optimal conditions, the obtained calibration plot for the standard positive serum was approximately linear within the dilution range of 1:80 to 1:5120. The limit of detection for the assay was 1:10,240 (S/N = 3), which is much lower than that typically achieved with an enzyme-linked immunosorbent assay (1:160; S/N = 3). A series of repeatability measurements using 1:320-fold diluted standard positive serum gave reproducible results with a relative standard deviation of 4.9% (n = 11). The ability of the immunosensor to analyze clinical samples was tested on porcine sera. The immunosensor had an efficiency of 90%, a sensitivity of 93.3%, and a specificity of 87.5% relative to the enzyme-linked immunosorbent assay results. Copyright © 2013 John Wiley & Sons, Ltd.
Towne, Samuel D; Anderson, Kelsey E; Smith, Matthew Lee; Dahlke, Deborah Vollmer; Kellstedt, Debra; Purcell, Ninfa Pena; Ory, Marcia G
2015-09-03
Worksite wellness initiatives for health promotion and health education have demonstrated effectiveness in improving employee health and wellness. We examined the effects of a multifaceted health promotion campaign on organizational capacity to meet requirements to become CEO Cancer Gold Standard Accredited. We conducted an online survey to assess perceived organizational values and support for the five CEO Cancer Gold Standard Pillars for cancer prevention: tobacco cessation; physical activity; nutrition; cancer screening and early detection; and accessing information on cancer clinical trials. Baseline and follow-up surveys were sent 6-months apart to faculty, staff, and students at a school of public health to test the impact of a multifaceted health promotion campaign on perceived organizational change. Descriptive analyses were used to characterize percent improvement. Multivariate logistic regression analyses were used to control for participants' university status. The current organizational culture highly supported tobacco cessation at both time points. Significant improvements (p < .05) from baseline to follow-up were observed for questions measuring organizational values for 'prevention, screening, and early detection of cancer' and 'accessing cancer treatment and clinical trials'. Health promotion and education efforts using multiple approaches were effective to improve perceived organizational values and support for cancer prevention and early detection, and increase access to information about cancer clinical trials. Future studies are needed to examine broader impacts of implementing worksite health promotion initiatives.
O'Connor Mooney, Rory; Davis, Niall Francis; Hoey, David; Hogan, Lisa; McGloughlin, Timothy M; Walsh, Michael T
2016-01-01
To investigate the repeatability of automatic decellularisation of porcine aortae using a non-enzymatic approach, addressing current limitations associated with other automatic decellularisation processes. Individual porcine aortae (n = 3) were resected and every third segment (n = 4) was allocated to one of three different groups: a control or a manually or automatically decellularised group. Manual and automatic decellularisation was performed using Triton X-100 (2% v/v) and sodium deoxycholate. Protein preservation and the elimination of a galactosyl-α(1,3)galactose (GAL) epitope were measured using immunohistochemistry and protein binding assays. The presence of residual DNA was determined with gel electrophoresis and spectrophotometry. Scaffold integrity was characterised with scanning electron microscopy and uni-axial tensile testing. Manual and automatic results were compared to one another, to control groups and to current gold standards. The results were comparable to those of current gold standard decellularisation techniques. Successful repeatability was achieved, both manually and automatically, with little effect on mechanical characteristics. Complete acellularity was not confirmed in either decellularisation group. Protein preservation was consistent in both the manually and automatically decellularised groups and between each individual aorta. Elimination of GAL was not achieved. Repeatable automatic decellularisation of porcine aortae is feasible using a Triton X-100-sodium deoxycholate protocol. Protein preservation was satisfactory; however, gold standard thresholds for permissible residual DNA levels were not achieved. Future research will focus on addressing this issue by optimisation of the existing protocol for thick tissues. © 2016 S. Karger AG, Basel.
A survey on annotation tools for the biomedical literature.
Neves, Mariana; Leser, Ulf
2014-03-01
New approaches to biomedical text mining crucially depend on the existence of comprehensive annotated corpora. Such corpora, commonly called gold standards, are important for learning patterns or models during the training phase, for evaluating and comparing the performance of algorithms and also for better understanding the information sought for by means of examples. Gold standards depend on human understanding and manual annotation of natural language text. This process is very time-consuming and expensive because it requires high intellectual effort from domain experts. Accordingly, the lack of gold standards is considered as one of the main bottlenecks for developing novel text mining methods. This situation led the development of tools that support humans in annotating texts. Such tools should be intuitive to use, should support a range of different input formats, should include visualization of annotated texts and should generate an easy-to-parse output format. Today, a range of tools which implement some of these functionalities are available. In this survey, we present a comprehensive survey of tools for supporting annotation of biomedical texts. Altogether, we considered almost 30 tools, 13 of which were selected for an in-depth comparison. The comparison was performed using predefined criteria and was accompanied by hands-on experiences whenever possible. Our survey shows that current tools can support many of the tasks in biomedical text annotation in a satisfying manner, but also that no tool can be considered as a true comprehensive solution.
Assessment of electrocardiographic criteria of left atrial enlargement.
Batra, Mahesh Kumar; Khan, Atif; Farooq, Fawad; Masood, Tariq; Karim, Musa
2018-05-01
Background Left atrial enlargement is considered to be a robust, strong, and widely acceptable indicator of cardiovascular outcomes. Echocardiography is the gold standard for measurement of left atrial size, but electrocardiography can be simple, cost-effective, and noninvasive in clinical practice. This study was undertaken to assess the diagnostic accuracy of an established electrocardiographic criterion for left atrial enlargement, taking 2-dimensional echocardiography as the gold-standard technique. Methods A cross-sectional study was conducted on 146 consecutively selected patients with the complaints of dyspnea and palpitation and with a murmur detected on clinical examination, from September 10, 2016 to February 10, 2017. Electrocardiography and echocardiography were performed in all patients. Patients with a negative P wave terminal force in lead V 1 > 40 ms·mm on electrocardiography or left atrial dimension > 40 mm on echocardiography were classified as having left atrial enlargement. Sensitivity and specificity were calculated to assess the diagnostic accuracy. Results Taking 2-dimensional echocardiography as the gold-standard technique, electrocardiography correctly diagnosed 68 patients as positive for left atrial enlargement and 12 as negative. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of electrocardiography for left atrial enlargement were 54.4%, 57.1%, 88.3%, 17.4%, and 54.8%, respectively. Conclusion The electrocardiogram appears to be a reasonable indicator of left atrial enlargement. In case of nonavailability of echocardiography, electrocardiography can be used for diagnosis of left atrial enlargement.
Fully automated MR liver volumetry using watershed segmentation coupled with active contouring.
Huynh, Hieu Trung; Le-Trong, Ngoc; Bao, Pham The; Oto, Aytek; Suzuki, Kenji
2017-02-01
Our purpose is to develop a fully automated scheme for liver volume measurement in abdominal MR images, without requiring any user input or interaction. The proposed scheme is fully automatic for liver volumetry from 3D abdominal MR images, and it consists of three main stages: preprocessing, rough liver shape generation, and liver extraction. The preprocessing stage reduced noise and enhanced the liver boundaries in 3D abdominal MR images. The rough liver shape was revealed fully automatically by using the watershed segmentation, thresholding transform, morphological operations, and statistical properties of the liver. An active contour model was applied to refine the rough liver shape to precisely obtain the liver boundaries. The liver volumes calculated by the proposed scheme were compared to the "gold standard" references which were estimated by an expert abdominal radiologist. The liver volumes computed by using our developed scheme excellently agreed (Intra-class correlation coefficient was 0.94) with the "gold standard" manual volumes by the radiologist in the evaluation with 27 cases from multiple medical centers. The running time was 8.4 min per case on average. We developed a fully automated liver volumetry scheme in MR, which does not require any interaction by users. It was evaluated with cases from multiple medical centers. The liver volumetry performance of our developed system was comparable to that of the gold standard manual volumetry, and it saved radiologists' time for manual liver volumetry of 24.7 min per case.
Weizman, Lior; Sira, Liat Ben; Joskowicz, Leo; Rubin, Daniel L.; Yeom, Kristen W.; Constantini, Shlomi; Shofty, Ben; Bashat, Dafna Ben
2014-01-01
Purpose: Tracking the progression of low grade tumors (LGTs) is a challenging task, due to their slow growth rate and associated complex internal tumor components, such as heterogeneous enhancement, hemorrhage, and cysts. In this paper, the authors show a semiautomatic method to reliably track the volume of LGTs and the evolution of their internal components in longitudinal MRI scans. Methods: The authors' method utilizes a spatiotemporal evolution modeling of the tumor and its internal components. Tumor components gray level parameters are estimated from the follow-up scan itself, obviating temporal normalization of gray levels. The tumor delineation procedure effectively incorporates internal classification of the baseline scan in the time-series as prior data to segment and classify a series of follow-up scans. The authors applied their method to 40 MRI scans of ten patients, acquired at two different institutions. Two types of LGTs were included: Optic pathway gliomas and thalamic astrocytomas. For each scan, a “gold standard” was obtained manually by experienced radiologists. The method is evaluated versus the gold standard with three measures: gross total volume error, total surface distance, and reliability of tracking tumor components evolution. Results: Compared to the gold standard the authors' method exhibits a mean Dice similarity volumetric measure of 86.58% and a mean surface distance error of 0.25 mm. In terms of its reliability in tracking the evolution of the internal components, the method exhibits strong positive correlation with the gold standard. Conclusions: The authors' method provides accurate and repeatable delineation of the tumor and its internal components, which is essential for therapy assessment of LGTs. Reliable tracking of internal tumor components over time is novel and potentially will be useful to streamline and improve follow-up of brain tumors, with indolent growth and behavior. PMID:24784396
Smith, Mackensie C; Crist, Rachael M; Clogston, Jeffrey D; McNeil, Scott E
2015-05-01
Surface characteristics of a nanoparticle, such as functionalization with polyethylene glycol (PEG), are critical to understand and achieve optimal biocompatibility. Routine physicochemical characterization such as UV-vis spectroscopy (for gold nanoparticles), dynamic light scattering, and zeta potential are commonly used to assess the presence of PEG. However, these techniques are merely qualitative and are not sensitive enough to distinguish differences in PEG quantity, density, or presentation. As an alternative, two methods are described here which allow for quantitative measurement of PEG on PEGylated gold nanoparticles. The first, a displacement method, utilizes dithiothreitol to displace PEG from the gold surface. The dithiothreitol-coated gold nanoparticles are separated from the mixture via centrifugation, and the excess dithiothreitol and dissociated PEG are separated through reversed-phase high-performance liquid chromatography (RP-HPLC). The second, a dissolution method, utilizes potassium cyanide to dissolve the gold nanoparticles and liberate PEG. Excess CN(-), Au(CN)2 (-), and free PEG are separated using RP-HPLC. In both techniques, the free PEG can be quantified against a standard curve using charged aerosol detection. The displacement and dissolution methods are validated here using 2-, 5-, 10-, and 20-kDa PEGylated 30-nm colloidal gold nanoparticles. Further value in these techniques is demonstrated not only by quantitating the total PEG fraction but also by being able to be adapted to quantitate the free unbound PEG and the bound PEG fractions. This is an important distinction, as differences in the bound and unbound PEG fractions can affect biocompatibility, which would not be detected in techniques that only quantitate the total PEG fraction.
Cordy, Paul; Veiga, Marcello; Crawford, Ben; Garcia, Oseas; Gonzalez, Victor; Moraga, Daniel; Roeser, Monika; Wip, Dennis
2013-08-01
Artisanal miners sell their gold to shops that are usually located in the urban core, where the mercury-gold amalgam is burned to evaporate the mercury that was added during ore processing. People living and working near these gold shops are exposed to intermittent and extreme concentrations of mercury vapour. In the urban centres of Segovia, Colombia, and Andacollo, Chile, the average concentrations measured by mobile mercury vapour analyzer transects taken repeatedly over several weeks were 1.26 and 0.338μgm(-3), respectively. By World Health Organization standards, these towns are exposed to significant health hazard, and globally, the millions of miners, as well as non-miners who live near gold shops, are at serious risk of neurological and renal deficits. Measurements taken in Suriname, Ecuador and Peru reveal this to be a widespread phenomenon with unique regional variations and myriad attempts at remediation. Maps of average mercury concentrations show the spatial distribution of the hazard in relation to residential buildings and schools. Measurements from towers show the temporal variability of mercury concentrations, and suggest that large quantities of mercury are available for long-range atmospheric transport. Mercury mapping in Segovia in 2011 suggest a 10% reduction in airborne mercury concentrations over 2010, despite a 30% increase in gold production. This is attributable to the adoption of retorts by miners and regulations banning new processing centres to the rural periphery. This is the first full description of artisanal mining gold shop practices and of the character, quantity, and remediation of mercury emissions within urban mining centres. Copyright © 2013 Elsevier Inc. All rights reserved.
Van Hecke, Wim; Sijbers, Jan; De Backer, Steve; Poot, Dirk; Parizel, Paul M; Leemans, Alexander
2009-07-01
Although many studies are starting to use voxel-based analysis (VBA) methods to compare diffusion tensor images between healthy and diseased subjects, it has been demonstrated that VBA results depend heavily on parameter settings and implementation strategies, such as the applied coregistration technique, smoothing kernel width, statistical analysis, etc. In order to investigate the effect of different parameter settings and implementations on the accuracy and precision of the VBA results quantitatively, ground truth knowledge regarding the underlying microstructural alterations is required. To address the lack of such a gold standard, simulated diffusion tensor data sets are developed, which can model an array of anomalies in the diffusion properties of a predefined location. These data sets can be employed to evaluate the numerous parameters that characterize the pipeline of a VBA algorithm and to compare the accuracy, precision, and reproducibility of different post-processing approaches quantitatively. We are convinced that the use of these simulated data sets can improve the understanding of how different diffusion tensor image post-processing techniques affect the outcome of VBA. In turn, this may possibly lead to a more standardized and reliable evaluation of diffusion tensor data sets of large study groups with a wide range of white matter altering pathologies. The simulated DTI data sets will be made available online (http://www.dti.ua.ac.be).
Chemistry in Past and New Science Frameworks and Standards: Gains, Losses, and Missed Opportunities
ERIC Educational Resources Information Center
Talanquer, Vicente; Sevian, Hannah
2014-01-01
Science education frameworks and standards play a central role in the development of curricula and assessments, as well as in guiding teaching practices in grades K-12. Recently, the National Research Council published a new Framework for K-12 Science Education that has guided the development of the Next Generation Science Standards. In this…
Q and A about the College, Career, and Civic Life (C3) Framework for Social Studies State Standards
ERIC Educational Resources Information Center
Herczog, Michelle
2013-01-01
The "College, Career, and Civic Life (C3) Framework for Social Studies State Standards: State Guidance for Enhancing the Rigor of K-12 Civics, Economics, Geography, and History" will soon be released. The C3 Framework was developed to serve two audiences: for states to upgrade their state social studies standards, and for…
Jagannathan, V; Mullett, Charles J; Arbogast, James G; Halbritter, Kevin A; Yellapragada, Deepthi; Regulapati, Sushmitha; Bandaru, Pavani
2009-04-01
We assessed the current state of commercial natural language processing (NLP) engines for their ability to extract medication information from textual clinical documents. Two thousand de-identified discharge summaries and family practice notes were submitted to four commercial NLP engines with the request to extract all medication information. The four sets of returned results were combined to create a comparison standard which was validated against a manual, physician-derived gold standard created from a subset of 100 reports. Once validated, the individual vendor results for medication names, strengths, route, and frequency were compared against this automated standard with precision, recall, and F measures calculated. Compared with the manual, physician-derived gold standard, the automated standard was successful at accurately capturing medication names (F measure=93.2%), but performed less well with strength (85.3%) and route (80.3%), and relatively poorly with dosing frequency (48.3%). Moderate variability was seen in the strengths of the four vendors. The vendors performed better with the structured discharge summaries than with the clinic notes in an analysis comparing the two document types. Although automated extraction may serve as the foundation for a manual review process, it is not ready to automate medication lists without human intervention.
Bayesian randomized clinical trials: From fixed to adaptive design.
Yin, Guosheng; Lam, Chi Kin; Shi, Haolun
2017-08-01
Randomized controlled studies are the gold standard for phase III clinical trials. Using α-spending functions to control the overall type I error rate, group sequential methods are well established and have been dominating phase III studies. Bayesian randomized design, on the other hand, can be viewed as a complement instead of competitive approach to the frequentist methods. For the fixed Bayesian design, the hypothesis testing can be cast in the posterior probability or Bayes factor framework, which has a direct link to the frequentist type I error rate. Bayesian group sequential design relies upon Bayesian decision-theoretic approaches based on backward induction, which is often computationally intensive. Compared with the frequentist approaches, Bayesian methods have several advantages. The posterior predictive probability serves as a useful and convenient tool for trial monitoring, and can be updated at any time as the data accrue during the trial. The Bayesian decision-theoretic framework possesses a direct link to the decision making in the practical setting, and can be modeled more realistically to reflect the actual cost-benefit analysis during the drug development process. Other merits include the possibility of hierarchical modeling and the use of informative priors, which would lead to a more comprehensive utilization of information from both historical and longitudinal data. From fixed to adaptive design, we focus on Bayesian randomized controlled clinical trials and make extensive comparisons with frequentist counterparts through numerical studies. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Xu, Daili; Huang, Wei; Zhang, Letian
2017-03-01
The West Qinling belt is the westward extensioin of the Qinling-Dabie-Sulu orogen in central China. It links the Kunlun and Qilian orogens to the west and the Songpan-Ganze belt to the south, making it an important tectonics syntaxis in China. According to the collection and analysis of the data of West Qinling Mountains gold deposit metallogenic chronology, the gold deposits in this area can be divided into five groups by time: 225-245 Ma, 220-190 Ma, 170 Ma±, 135-110 Ma, 75-45 Ma. The formation time is related to the geological process at that time. The relationship between the formation of gold deposit and geological structure can be explored by the research on the present geological structures. According to the regional tectonic evolution and magmatic activity, the gold deposits are divided into four metallogenic epoches: from the end of the Indo-Chinese epoch to the early Yanshanian (245-225 Ma), is one of the initial stages of gold mineralization; the early and the middle Yanshanian (220-190 Ma, 170 Ma±), is the main forming time of the gold mineralization in the West Qinling; the late Yanshanian (135-110 Ma), is the superimposed mineralization stage; at last, the effect of Himalayan hydrothermal activity to the gold deposits. Under the support of three projects naemed " the research on the conductivity of the lithosphere of the Central Orogenic in China ", " the MT array observation of the intersection area of COC(Central Orogen in China) and the North-South seismic belt ", " the experiment research of MT standard network observation in the area of Qinghai-Tibetan Plateau and the North-China " (Sinoprobe-01-02), we collected massive magnetotellurics data for futher study of the present geological strusctures to discess the relationship between gold deposites and geotectonic in West Qinling.
ERIC Educational Resources Information Center
Liu, Xueman Lucy; de Villiers, Jill; Ning, Chunyan; Rolfhus, Eric; Hutchings, Teresa; Lee, Wendy; Jiang, Fan; Zhang, Yi Wen
2017-01-01
Purpose: With no existing gold standard for comparison, challenges arise for establishing the validity of a new standardized Mandarin language assessment normed in mainland China. Method: A new assessment, Diagnostic Receptive and Expressive Assessment of Mandarin (DREAM), was normed with a stratified sample of 969 children ages 2;6 (years;months)…
ERIC Educational Resources Information Center
Venetsanou, Fotini; Kambas, Antonis; Ellinoudis, Theodoros; Fatouros, Ioannis; Giannakidou, Dimitra; Kourtessis, Thomas
2011-01-01
Developmental Coordination Disorder (DCD) is an important risk factor in the development of children that can have a significant academic and social impact. This reinforces the need for its timely identification using appropriate assessment methods and accurate screening tests. The commonly used standardized motor test for the DCD identification…
Schoolcraft, William; Meseguer, Marcos
2017-10-01
Infertility affects over 70 million couples globally. Access to, and interest in, assisted reproductive technologies is growing worldwide, with more couples seeking medical intervention to conceive, in particular by IVF. Despite numerous advances in IVF techniques since its first success in 1978, almost half of the patients treated remain childless. The multifactorial nature of IVF treatment means that success is dependent on many variables. Therefore, it is important to examine how each variable can be optimized to achieve the best possible outcomes for patients. The current approach to IVF is fragmented, with various protocols in use. A systematic approach to establishing optimum best practices may improve IVF success and live birth rates. Our vision of the future is that technological advancements in the laboratory setting are standardized and universally adopted to enable a gold standard of care. Implementation of best practices for laboratory procedures will enable clinicians to generate high-quality gametes, and to produce and identify gametes and embryos of maximum viability and implantation potential, which should contribute to improving take-home healthy baby rates. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Industrial Education. Vocational Education Program Courses Standards.
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. Div. of Vocational, Adult, and Community Education.
This document contains vocational education program courses standards (curriculum frameworks and student performance standards) for exploratory courses, practical arts courses, and job preparatory programs offered at the secondary or postsecondary level in Florida. Each program courses standard is composed of two parts: a curriculum framework and…
Quint, Jennifer K; Müllerova, Hana; DiSantostefano, Rachael L; Forbes, Harriet; Eaton, Susan; Hurst, John R; Davis, Kourtney; Smeeth, Liam
2014-01-01
Objectives The optimal method of identifying people with chronic obstructive pulmonary disease (COPD) from electronic primary care records is not known. We assessed the accuracy of different approaches using the Clinical Practice Research Datalink, a UK electronic health record database. Setting 951 participants registered with a CPRD practice in the UK between 1 January 2004 and 31 December 2012. Individuals were selected for ≥1 of 8 algorithms to identify people with COPD. General practitioners were sent a brief questionnaire and additional evidence to support a COPD diagnosis was requested. All information received was reviewed independently by two respiratory physicians whose opinion was taken as the gold standard. Primary outcome measure The primary measure of accuracy was the positive predictive value (PPV), the proportion of people identified by each algorithm for whom COPD was confirmed. Results 951 questionnaires were sent and 738 (78%) returned. After quality control, 696 (73.2%) patients were included in the final analysis. All four algorithms including a specific COPD diagnostic code performed well. Using a diagnostic code alone, the PPV was 86.5% (77.5–92.3%) while requiring a diagnosis plus spirometry plus specific medication; the PPV was slightly higher at 89.4% (80.7–94.5%) but reduced case numbers by 10%. Algorithms without specific diagnostic codes had low PPVs (range 12.2–44.4%). Conclusions Patients with COPD can be accurately identified from UK primary care records using specific diagnostic codes. Requiring spirometry or COPD medications only marginally improved accuracy. The high accuracy applies since the introduction of an incentivised disease register for COPD as part of Quality and Outcomes Framework in 2004. PMID:25056980
Brook, Olga R; Gourtsoyianni, Sofia; Brook, Alexander; Mahadevan, Anand; Wilcox, Carol; Raptopoulos, Vassilios
2012-06-01
To evaluate spectral computed tomography (CT) with metal artifacts reduction software (MARS) for reduction of metal artifacts associated with gold fiducial seeds. Thirteen consecutive patients with 37 fiducial seeds implanted for radiation therapy of abdominal lesions were included in this HIPAA-compliant, institutional review board-approved prospective study. Six patients were women (46%) and seven were men (54%). The mean age was 61.1 years (median, 58 years; range, 29-78 years). Spectral imaging was used for arterial phase CT. Images were reconstructed with and without MARS in axial, coronal, and sagittal planes. Two radiologists independently reviewed reconstructions and selected the best image, graded the visibility of the tumor, and assessed the amount of artifacts in all planes. A linear-weighted κ statistic and Wilcoxon signed-rank test were used to assess interobserver variability. Histogram analysis with the Kolmogorov-Smirnov test was used for objective evaluation of artifacts reduction. Fiducial seeds were placed in pancreas (n = 5), liver (n = 7), periportal lymph nodes (n = 1), and gallbladder bed (n = 1). MARS-reconstructed images received a better grade than those with standard reconstruction in 60% and 65% of patients by the first and second radiologist, respectively. Tumor visibility was graded higher with standard versus MARS reconstruction (grade, 3.7 ± 1.0 vs 2.8 ± 1.1; P = .001). Reduction of blooming was noted on MARS-reconstructed images (P = .01). Amount of artifacts, for both any and near field, was significantly smaller on sagittal and coronal MARS-reconstructed images than on standard reconstructions (P < .001 for all comparisons). Far-field artifacts were more prominent on axial MARS-reconstructed images than on standard reconstructions (P < .01). Linear-weighted κ statistic showed moderate to perfect agreement between radiologists. CT number distribution was narrower with MARS than with standard reconstruction in 35 of 37 patients (P < .001). Spectral CT with use of MARS improved tumor visibility in the vicinity of gold fiducial seeds.
Papuga, Mark O; Mesfin, Addisu; Molinari, Robert; Rubery, Paul T
2016-07-15
A prospective and retrospective cross-sectional cohort analysis. The aim of this study was to show that Patient-Reported Outcomes Measurement Information System (PROMIS) computer adaptive testing (CAT) assessments for physical function and pain interference can be efficiently collected in a standard office visit and to evaluate these scores with scores from previously validated Oswestry Disability Index (ODI) and Neck Disability Index (NDI) providing evidence of convergent validity for use in patients with spine pathology. Spinal surgery outcomes are highly variable, and substantial debate continues regarding the role and value of spine surgery. The routine collection of patient-based outcomes instruments in spine surgery patients may inform this debate. Traditionally, the inefficiency associated with collecting standard validated instruments has been a barrier to routine use in outpatient clinics. We utilized several CAT instruments available through PROMIS and correlated these with the results obtained using "gold standard" legacy outcomes measurement instruments. All measurements were collected at a routine clinical visit. The ODI and the NDI assessments were used as "gold standard" comparisons for patient-reported outcomes. PROMIS CAT instruments required 4.5 ± 1.8 questions and took 35 ± 16 seconds to complete, compared with ODI/NDI requiring 10 questions and taking 188 ± 85 seconds when administered electronically. Linear regression analysis of retrospective scores involving a primary back complaint revealed moderate to strong correlations between ODI and PROMIS physical function with r values ranging from 0.5846 to 0.8907 depending on the specific assessment and patient subsets examined. Routine collection of physical function outcome measures in clinical practice offers the ability to inform and improve patient care. We have shown that several PROMIS CAT instruments can be efficiently administered during routine clinical visits. The moderate to strong correlations found validate the utility of computer adaptive testing when compared with the gold standard "static" legacy assessments. 4.
Advanced aviation environmental modeling tools to inform policymakers
DOT National Transportation Integrated Search
2012-08-19
Aviation environmental models which conform to international guidance have advanced : over the past several decades. Enhancements to algorithms and databases have increasingly : shown these models to compare well with gold standard measured data. The...
Persichetti, Maria Flaminia; Solano-Gallego, Laia; Vullo, Angela; Masucci, Marisa; Marty, Pierre; Delaunay, Pascal; Vitale, Fabrizio; Pennisi, Maria Grazia
2017-03-13
Anti-Leishmania antibodies are increasingly investigated in cats for epidemiological studies or for the diagnosis of clinical feline leishmaniosis. The immunofluorescent antibody test (IFAT), the enzyme-linked immunosorbent assay (ELISA) and western blot (WB) are the serological tests more frequently used. The aim of the present study was to assess diagnostic performance of IFAT, ELISA and WB to detect anti-L. infantum antibodies in feline serum samples obtained from endemic (n = 76) and non-endemic (n = 64) areas and from cats affected by feline leishmaniosis (n = 21) by a Bayesian approach without a gold standard. Cut-offs were set at 80 titre for IFAT and 40 ELISA units for ELISA. WB was considered positive in presence of at least a 18 KDa band. Statistical analysis was performed through a written routine with MATLAB software in the Bayesian framework. The latent data and observations from the joint posterior were simulated in the Bayesian approach by an iterative Markov Chain Monte Carlo technique using the Gibbs sampler for estimating sensitivity and specificity of the three tests. The median seroprevalence in the sample used for evaluating the performance of tests was estimated at 0.27 [credible interval (CI) = 0.20-0.34]. The median sensitivity of the three different methods was 0.97 (CI: 0.86-1.00), 0.75 (CI: 0.61-0.87) and 0.70 (CI: 0.56-0.83) for WB, IFAT and ELISA, respectively. Median specificity reached 0.99 (CI: 0.96-1.00) with WB, 0.97 (CI: 0.93-0.99) with IFAT and 0.98 (CI: 0.94-1.00) with ELISA. IFAT was more sensitive than ELISA (75 vs 70%) for the detection of subclinical infection while ELISA was better for diagnosing clinical leishmaniosis when compared with IFAT (98 vs 97%). The overall performance of all serological techniques was good and the most accurate test for anti-Leishmania antibody detection in feline serum samples was WB.
Williams, Holly; Downes, Elizabeth
2017-11-01
The effects of climate change are far-reaching and multifactorial, with potential impacts on food security and conflict. Large population movements, whether from the aftermath of natural disasters or resulting from conflict, can precipitate the need for humanitarian response in what can become complex humanitarian emergencies (CHEs). Nurses need to be prepared to respond to affected communities in need, whether the emergency is domestic or global. The purpose of the article is to describe a novel course for nursing students interested in practice within the confines of CHEs and natural disasters. The authors used the Sphere Humanitarian Charter and Minimum Standards as a practical framework to inform the course development. They completed a review of the literature on the interaction on climate change, conflict and health, and competencies related to working CHEs. Resettled refugees, as well as experts in the area of humanitarian response, recovery, and mitigation from the Centers for Disease Control and Prevention and nongovernmental organizations further informed the development of the course. This course prepares the nursing workforce to respond appropriately to large population movements that may arise from the aftermath of natural disasters or conflict, both of which can comprise a complex humanitarian disaster. Using The Sphere Project e-learning course, students learn about the Sphere Project, which works to ensure accountability and quality in humanitarian response and offers core minimal standards for technical assistance. These guidelines are seen globally as the gold standard for humanitarian response and address many of the competencies for disaster nursing (http://www.sphereproject.org/learning/e-learning-course/). © 2017 Sigma Theta Tau International.
De Santis, Roberto; Gloria, Antonio; Russo, Teresa; D'Amora, Ugo; Varriale, Angelo; Veltri, Mario; Balleri, Piero; Mollica, Francesco; Riccitiello, Francesco; Ambrosio, Luigi
2014-12-18
This study aimed at investigating the effects of titanium implants and different configurations of full-arch prostheses on the biomechanics of edentulous mandibles. Reverse engineered, composite, anisotropic, edentulous mandibles made of a poly(methylmethacrylate) core and a glass fibre reinforced outer shell were rapid prototyped and instrumented with strain gauges. Brånemark implants RP platforms in conjunction with titanium Procera one-piece or two-piece bridges were used to simulate oral rehabilitations. A lateral load through the gonion regions was used to test the biomechanical effects of the rehabilitations. In addition, strains due to misfit of the one-piece titanium bridge were compared to those produced by one-piece cast gold bridges. Milled titanium bridges had a better fit than cast gold bridges. The stress distribution in mandibular bone rehabilitated with a one-piece bridge was more perturbed than that observed with a two-piece bridge. In particular the former induced a stress concentration and stress shielding in the molar and symphysis regions, while for the latter design these stresses were strongly reduced. In conclusion, prosthetic frameworks changed the biomechanics of the mandible as a result of both their design and manufacturing technology. Copyright © 2014 Elsevier Ltd. All rights reserved.
Dextran templating for the synthesis of metallic and metal oxide sponges
NASA Astrophysics Data System (ADS)
Walsh, Dominic; Arcelli, Laura; Ikoma, Toshiyuki; Tanaka, Junzo; Mann, Stephen
2003-06-01
Silver or gold-containing porous frameworks have been used extensively in catalysis, electrochemistry, heat dissipation and biofiltration. These materials are often prepared by thermal reduction of metal-ion-impregnated porous insoluble supports (such as alumina and pumice), and have surface areas of about 1 m2 g-1, which is typically higher than that obtained for pure metal powders or foils prepared electrolytically or by infiltration and thermal decomposition of insoluble cellulose supports. Starch gels have been used in association with zeolite nanoparticles to produce porous inorganic materials with structural hierarchy, but the use of soft sacrificial templates in the synthesis of metallic sponges has not been investigated. Here we demonstrate that self-supporting macroporous frameworks of silver, gold and copper oxide, as well as composites of silver/copper oxide or silver/titania can be routinely prepared by heating metal-salt-containing pastes of the polysaccharide, dextran, to temperatures between 500 and 900 °C. Magnetic sponges were similarly prepared by replacing the metal salt precursor with preformed iron oxide (magnetite) nanoparticles. The use of dextran as a sacrificial template for the fabrication of metallic and metal oxide sponges should have significant benefits over existing technologies because the method is facile, inexpensive, environmentally benign, and amenable to scale-up and processing.
Casting inorganic structures with DNA molds
Sun, Wei; Boulais, Etienne; Hakobyan, Yera; ...
2014-10-09
Here we report a general strategy for designing and synthesizing inorganic nanostructures with arbitrarily prescribed three-dimensional shapes. Computationally designed DNA strands self-assemble into a stiff “nano-mold” that contains a user-specified three-dimensional cavity and encloses a nucleating gold “seed”. Under mild conditions, this seed grows into a larger cast structure that fills and thus replicates the cavity. We synthesized a variety of nanoparticles with three nanometer resolution: three distinct silver cuboids with three independently tunable dimensions, silver and gold nanoparticles with diverse cross sections, and composite structures with homo-/heterogeneous components. The designer equilateral silver triangular and spherical nanoparticles exhibited plasmonic propertiesmore » consistent with electromagnetism-based simulations. Our framework is generalizable to more complex geometries and diverse inorganic materials, offering a range of applications in biosensing, photonics, and nanoelectronics.« less
Casting inorganic structures with DNA molds.
Sun, Wei; Boulais, Etienne; Hakobyan, Yera; Wang, Wei Li; Guan, Amy; Bathe, Mark; Yin, Peng
2014-11-07
We report a general strategy for designing and synthesizing inorganic nanostructures with arbitrarily prescribed three-dimensional shapes. Computationally designed DNA strands self-assemble into a stiff "nanomold" that contains a user-specified three-dimensional cavity and encloses a nucleating gold "seed." Under mild conditions, this seed grows into a larger cast structure that fills and thus replicates the cavity. We synthesized a variety of nanoparticles with 3-nanometer resolution: three distinct silver cuboids with three independently tunable dimensions, silver and gold nanoparticles with diverse cross sections, and composite structures with homo- and heterogeneous components. The designer equilateral silver triangular and spherical nanoparticles exhibited plasmonic properties consistent with electromagnetism-based simulations. Our framework is generalizable to more complex geometries and diverse inorganic materials, offering a range of applications in biosensing, photonics, and nanoelectronics. Copyright © 2014, American Association for the Advancement of Science.
NASA Astrophysics Data System (ADS)
Yeh, Ting-Tso; Huang, Tsung-Yu; Tanaka, Takuo; Yen, Ta-Jen
2017-04-01
We design and construct a three-dimensional (3D) negative index medium (NIM) composed of gold hemispherical shells to supplant an integration of a split-ring resonator and a discrete plasmonic wire for both negative permeability and permittivity at THz gap. With the proposed highly symmetric gold hemispherical shells, the negative index is preserved at multiple incident angles ranging from 0° to 85° for both TE and TM waves, which is further evidenced by negative phase flows in animated field distributions and outweighs conventional fishnet structures with operating frequency shifts when varying incident angles. Finally, the fabrication of the gold hemispherical shells is facilitated via standard UV lithographic and isotropic wet etching processes and characterized by μ-FTIR. The measurement results agree the simulated ones very well.
Remote micro-encapsulation of curium-gold cermets
NASA Astrophysics Data System (ADS)
Coops, M. S.; Voegele, A. L.; Hayes, W. N.; Sisson, D. H.
1982-09-01
A technique has been developed to produce miniature, high-density capsules of curium-244 oxide contained in three concentric jackets of metallic gold or silver. The final capsules are right circular cylinders, 6.350 mm diameter by (3.18±0.05) mm long, with a minimum density of 11.0 g/cm 3. Each level of containment was soldered or brazed closed, with the outer surface free of detectable alpha contamination. Fabrication was performed in three separate small cells operated by standard master-slave manipulators. Production capsules have been stored for up to five years without indication of dimensional growth or leakage of radioactive contents. The dimensional stability of the capsules is attributed to the microporous structure of the plated-gold structure which permits helium gas resulting from alpha decay to diffuse through the capsule wall while retaining all radioactive materials.
Building Assured Systems Framework
2010-09-01
of standards such as ISO 27001 as frameworks [NASCIO 2009]. In this context, a framework is a standard intended to assist in auditing and compliance...Information Security ISO /IEC 27004 Information technology – Security techniques - Information security management measurement ISO /IEC 15939, System and
Indirect Determination of the Thermodynamic Temperature of a Gold Fixed-Point Cell
NASA Astrophysics Data System (ADS)
Battuello, M.; Girard, F.; Florio, M.
2010-09-01
Since the value T 90(Au) was fixed on the ITS-90, some determinations of the thermodynamic temperature of the gold point have been performed which form, with other renormalized results of previous measurements by radiation thermometry, the basis for the current best estimates of ( T - T 90)Au = 39.9 mK as elaborated by the CCT-WG4. Such a value, even if consistent with the behavior of T - T 90 differences at lower temperatures, is quite influenced by the low values of T Au as determined with few radiometric measurements. At INRIM, an independent indirect determination of the thermodynamic temperature of gold was performed by means of a radiation thermometry approach. A fixed-point technique was used to realize approximated thermodynamic scales from the Zn point up to the Cu point. A Si-based standard radiation thermometer working at 900 nm and 950 nm was used. The low uncertainty presently associated to the thermodynamic temperature of fixed points and the accuracy of INRIM realizations, allowed scales with an uncertainty lower than 0.03 K in terms of the thermodynamic temperature to be realized. A fixed-point cell filled with gold, 99.999 % in purity, was measured, and its freezing temperature was determined by both interpolation and extrapolation. An average T Au = 1337.395 K was found with a combined standard uncertainty of 23 mK. Such a value is 25 mK higher than the presently available value as derived by the CCT-WG4 value of ( T - T 90)Au = 39.9 mK.
Health Occupations Education. Vocational Education Program Courses Standards.
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. Div. of Vocational, Adult, and Community Education.
This document contains vocational education program courses standards for exploratory courses, practical arts courses, and job preparatory programs offered at the secondary or postsecondary level. Each program standard is composed of two parts: a curriculum framework and student performance standards. The curriculum framework includes four major…
NASA Astrophysics Data System (ADS)
Bucharskaya, A. B.; Pakhomy, S. S.; Zlobina, O. V.; Maslyakova, G. N.; Matveeva, O. V.; Bugaeva, I. O.; Navolokin, N. A.; Khlebtsov, B. N.; Bogatyrev, V. A.; Khlebtsov, N. G.; Tuchin, V. V.
2016-03-01
The wide application of nanotechnologies in medicine requires the careful study of various aspects of their potential safety. The effects of prolonged peroral administration of gold nanoparticles on morphological changes in lymphoid organs and indicators of peripheral blood of laboratory animals were investigated in experiment. The gold nanospheres functionalized with thiolated polyethylene glycol sizes 2, 15 and 50 nm were administered orally for 15 days to outbred white rats at a dosage of 190 μg/kg of animal body weight. The standard histological and hematological staining were used for morphological study of lymphoid organs and bone marrow smears. The size-dependent decrease of the number of neutrophils and lymphocytes was noted in the study of peripheral blood, especially pronounced after administration of gold nanoparticles with size of 50 nm. The stimulation of myelocytic germ of hematopoiesis was recorded at morphological study of the bone marrow. The signs of strengthening of the processes of differentiation and maturation of cellular elements were found in lymph nodes, which were showed as the increasing number of immunoblasts and large lymphocytes. The quantitative changes of cellular component morphology of lymphoid organs due to activation of migration, proliferation and differentiation of immune cells indicate the presence of immunostimulation effect of gold nanoparticles.
Disseminated gold-sulfide mineralization at the Zhaima deposit, eastern Kazakhstan
NASA Astrophysics Data System (ADS)
Kovalev, K. R.; Kuzmina, O. N.; Dyachkov, B. A.; Vladimirov, A. G.; Kalinin, Yu. A.; Naumov, E. A.; Kirillov, M. V.; Annikova, I. Yu.
2016-03-01
The Zhaima gold-sulfide deposit is located in the northwestern part of the West Kalba gold belt in eastern Kazakhstan. The mineralization is hosted in Lower Carboniferous volcanic and carbonate rocks formed under conditions of marginal-sea and island-arc volcanic activity. The paper considers the mineralogy and geochemistry of primary gold-sulfide ore and Au-bearing weathering crusts. Au-bearing arsenopyrite-pyrite mineralization formed during only one productive stage. Disseminated, stringer-disseminated, and massive rocks are enriched in Ti, Cr, V, Cu, and Ni, which correspond to the mafic profile of basement. The main ores minerals are represented by finely acicular arsenopyrite containing Au (up to few tens of ppm) and cubic and pentagonal dodecahedral pyrite with sporadic submicroscopic inclusions of native gold. The sulfur isotopic composition of sulfides is close to that of the meteoritic standard (δ34S =-0.2 to +0.2). The 40Ar/39Ar age of three sericite samples from ore veinlets corresponds to the Early Permian: 279 ± 3.3, 275.6 ± 2.9, and 272.2 ± 2.9 Ma. The mantle source of sulfur, ore geochemistry, and spatial compatibility of mineralization with basic dikes allow us to speak about the existence of deep fluid-magmatic systems apparently conjugate with the Tarim plume.
Banana peel extract mediated synthesis of gold nanoparticles.
Bankar, Ashok; Joshi, Bhagyashree; Kumar, Ameeta Ravi; Zinjarde, Smita
2010-10-01
Gold nanoparticles were synthesized by using banana peel extract (BPE) as a simple, non-toxic, eco-friendly 'green material'. The boiled, crushed, acetone precipitated, air-dried peel powder was used to reduce chloroauric acid. A variety of nanoparticles were formed when the reaction conditions were altered with respect to pH, BPE content, chloroauric acid concentration and temperature of incubation. The reaction mixtures displayed vivid colors and UV-vis spectra characteristic of gold nanoparticles. Dynamic light scattering (DLS) studies revealed that the average size of the nanoparticles under standard synthetic conditions was around 300nm. Scanning electron microscopy and energy dispersive spectrometry (EDS) confirmed these results. A coffee ring phenomenon, led to the aggregation of the nanoparticles into microcubes and microwire networks towards the periphery of the air-dried samples. X-ray diffraction studies of the samples revealed spectra that were characteristic for gold. Fourier transform infra red (FTIR) spectroscopy indicated the involvement of carboxyl, amine and hydroxyl groups in the synthetic process. The BPE mediated nanoparticles displayed efficient antimicrobial activity towards most of the tested fungal and bacterial cultures.
Chaichi, Mohammad Javad; Azizi, Seyed Naser; Heidarpour, Maryam
2013-12-01
It was found that silver/gold alloy nanoparticles enhance the chemiluminescence (CL) of the luminol-H2O2 system in alkaline solution. The studies of UV-Vis spectra, CL spectra, effects of concentrations luminol, hydrogen peroxide and silver/gold alloy nanoparticles solutions were carried out to explore the CL enhancement mechanism. Flutamide was found to quench the CL signals of the luminol-H2O2 reaction catalyzed by silver/gold alloy nanoparticles, which made it applicable for the determination of flutamide. Under the optimum conditions, the CL intensity is proportional to the concentration of the flutamide in solution over the range 5.0 × 10(-7) to 1.0 × 10(-4)mol L(-1). Detection limit was obtained 1.2 × 10(-8)mol L(-1)and the relative standard deviation (RSD) γ5%. This work is introduced as a new method for the determination of flutamide in commercial tablets. Box-Behnken experimental design is applied to investigate and validate the CL measurement parameters. Copyright © 2013 Elsevier B.V. All rights reserved.
National Framework of Professional Standards for Change Leadership in Education
ERIC Educational Resources Information Center
Duffy, Francis M.
2009-01-01
The ten professional standards form what Francis Duffy refers to as a "National Framework of Professional Standards for Change Leadership in Education." Each standard has examples of the knowledge, skills, and dispositions that the research suggests are important for effective change leadership. Duffy's hope is that this proposed…
Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant.
Yoon, Ki-Joon; Park, Young-Bum; Choi, Hyunmin; Cho, Youngsung; Lee, Jae-Hoon; Lee, Keun-Woo
2016-12-01
The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 10 6 cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups ( P >.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.
Zaijun, Li; Jiaomai, Pan; Jian, Tang
2003-02-01
A excellent sensitive and selective method for spectrophotometric determination of trace gold has been developed, the method is based on the color reaction of gold(III) with new reagent 5-(2-hydroxy-5-nitrophenylazo)rhodanine (HNAR). Under optimal conditions, HNAR reacts with gold(III) to form a 1:5 orange complex, which has an maximum absorption peak at 480 nm. Maximum enhancement of the absorbance of the complex was obtained in the presence of the mixed surfactant of Triton X-100 and CTMAB; the reaction completed rapidly and the absorbance is stable for 5 h at least at 20 degrees C; 0-48 microg L(-1) Au(III) obeyed Beer's law. The apparent molar absorptivity of the complex, Sandell's sensitivity, the limit of quantification, the limit of detection and relative standard deviation were found to be 2.0x10(6) L mol(-1) cm(-1), 0.000,098,483 micro g cm(-2), 1.02 ng mL(-1), 0.35 ng mL(-1) and 1.09%, respectively. The effect of co-existing ions was studied seriously; most metal ions can be tolerated in considerable amounts. Its sensitivity and selectivity are remarkably superior to other reagents in the literature. The proposed method was used successfully to determine trace gold in geological samples. Moreover, the synthesis, characteristics and analytical reaction of HNAR with gold are also described in detail.
ERIC Educational Resources Information Center
Raveh, Ira; Koichu, Boris; Peled, Irit; Zaslavsky, Orit
2016-01-01
In this article we present an integrative framework of knowledge for teaching the standard algorithms of the four basic arithmetic operations. The framework is based on a mathematical analysis of the algorithms, a connectionist perspective on teaching mathematics and an analogy with previous frameworks of knowledge for teaching arithmetic…
Results of the National CT Colonography Trial: Questions and Answers
Learn the results of the National Computerized Tomographic Colonography (CTC) clinical trial, which evaluated how well CTC identifies participants with at least one significantly large polyp using colonoscopy as the gold (or reference) standard.
Code of Federal Regulations, 2012 CFR
2012-07-01
... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE CATEGORY Copper, Lead, Zinc, Gold, Silver, and Molybdenum Ores Subcategory § 440.105 Effluent limitations...
40 CFR 440.148 - Best Management Practices (BMP).
Code of Federal Regulations, 2011 CFR
2011-07-01
... GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Gold Placer Mine Subcategory § 440.148...: The amount of new water allowed to enter the plant site for use in ore processing shall be limited to...
Code of Federal Regulations, 2014 CFR
2014-07-01
... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE CATEGORY Copper, Lead, Zinc, Gold, Silver, and Molybdenum Ores Subcategory § 440.105 Effluent limitations...
Code of Federal Regulations, 2013 CFR
2013-07-01
... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ORE MINING AND DRESSING POINT SOURCE CATEGORY Copper, Lead, Zinc, Gold, Silver, and Molybdenum Ores Subcategory § 440.105 Effluent limitations...
Code of Federal Regulations, 2011 CFR
2011-07-01
... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Copper, Lead, Zinc, Gold, Silver, and Molybdenum Ores Subcategory § 440.105 Effluent limitations representing...
A contact-free respiration monitor for smart bed and ambulatory monitoring applications.
Hart, Adam; Tallevi, Kevin; Wickland, David; Kearney, Robert E; Cafazzo, Joseph A
2010-01-01
The development of a contact-free respiration monitor has a broad range of clinical applications in the home and hospital setting. Current approaches suffer from a variety of problems including unreliability, low sensitivity, and high cost. This work describes a novel approach to contact-free respiration monitoring that addresses these shortcomings by employing a highly sensitive capacitance sensor to detect variations in capacitive coupling caused by breathing. A prototype system consisting of a synthetic-metallic pad, sensor electronics, and iPhone interface was built and its performance compared experimentally to the gold standard technique (Respiratory Inductance Plethysmography) on both a healthy volunteer and SimMan robotic mannequin. The prototype sensor effectively captured respiratory movements over breathing rates of 5-55 bpm; achieving an average spectral correlation of 0.88 (CI: 0.86-0.90) and 0.95 (CI: 0.95-0.96) to the gold standard using the SimMan and healthy volunteer respectively.
The role of counterfactual theory in causal reasoning.
Maldonado, George
2016-10-01
In this commentary I review the fundamentals of counterfactual theory and its role in causal reasoning in epidemiology. I consider if counterfactual theory dictates that causal questions must be framed in terms of well-defined interventions. I conclude that it does not. I hypothesize that the interventionist approach to causal inference in epidemiology stems from elevating the randomized trial design to the gold standard for thinking about causal inference. I suggest that instead the gold standard we should use for thinking about causal inference in epidemiology is the thought experiment that, for example, compares an actual disease frequency under one exposure level with a counterfactual disease frequency under a different exposure level (as discussed in Greenland and Robins (1986) and Maldonado and Greenland (2002)). I also remind us that no method should be termed "causal" unless it addresses the effect of other biases in addition to the problem of confounding. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA researchers in gold control room during an F-15 HiDEC flight
NASA Technical Reports Server (NTRS)
1993-01-01
NASA researchers monitor equipment in the mission control Gold room at the Dryden Flight Research Center, Edwards, California, during a flight of an F-15 Highly Integrated Digital Electronic Control (HIDEC) research aircraft. The system was developed on the F-15 to investigate and demonstrate methods of obtaining optimum aircraft performance. The major elements of HIDEC were a Digital Electronic Flight Control System (DEFCS), a Digital Electronic Engine Control (DEEC), an on-board general purpose computer, and an integrated architecture to allow all components to 'talk to each other.' Unlike standard F-15s, which have a mechanical and analog electronic flight control system, the HIDEC F-15 also had a dual-channel, fail-safe digital flight control system programmed in Pascal. It was linked to the Military Standard 1553B and a H009 data bus which tied all the other electronic systems together.
Sensitivity of MRI of the spine compared with CT myelography in orthostatic headache with CSF leak.
Starling, Amaal; Hernandez, Fatima; Hoxworth, Joseph M; Trentman, Terrence; Halker, Rashmi; Vargas, Bert B; Hastriter, Eric; Dodick, David
2013-11-12
To investigate the sensitivity of MRI of the spine compared with CT myelography (CTM) in detecting CSF leaks. Between July 1998 and October 2010, 12 patients with orthostatic headache and a CTM-confirmed spinal CSF leak underwent an MRI of the spine with and without contrast. Using CTM as the gold standard, we retrospectively investigated the sensitivity of spinal MRI in detecting a CSF leak. Eleven of 12 patients with a CSF leak documented by CTM also had extradural fluid collections on spinal MRI (sensitivity 91.7%). Six patients with extradural fluid collections on spinal MRI also had spinal dural enhancement. When compared with the gold standard of CTM, MRI of the spine appears to be a sensitive and less invasive imaging modality for detecting a spinal CSF leak, suggesting that MRI of the spine should be the imaging modality of first choice for the detection of spinal CSF leaks.
Tsalik, Ephraim L.; Petzold, Elizabeth; Kreiswirth, Barry N.; Bonomo, Robert A.; Banerjee, Ritu; Lautenbach, Ebbing; Evans, Scott R.; Hanson, Kimberly E.; Klausner, Jeffrey D.
2017-01-01
Abstract Diagnostics are a cornerstone of the practice of infectious diseases. However, various limitations frequently lead to unmet clinical needs. In most other domains, diagnostics focus on narrowly defined questions, provide readily interpretable answers, and use true gold standards for development. In contrast, infectious diseases diagnostics must contend with scores of potential pathogens, dozens of clinical syndromes, emerging pathogens, rapid evolution of existing pathogens and their associated resistance mechanisms, and the absence of gold standards in many situations. In spite of these challenges, the importance and value of diagnostics cannot be underestimated. Therefore, the Antibacterial Resistance Leadership Group has identified diagnostics as 1 of 4 major areas of emphasis. Herein, we provide an overview of that development, highlighting several examples where innovation in study design, content, and execution is advancing the field of infectious diseases diagnostics. PMID:28350903
[The role of meta-analysis in assessing the treatment of advanced non-small cell lung cancer].
Pérol, M; Pérol, D
2004-02-01
Meta-analysis is a statistical method allowing an evaluation of the direction and quantitative importance of a treatment effect observed in randomized trials which have tested the treatment but have not provided a definitive conclusion. In the present review, we discuss the methodology and the contribution of meta-analyses to the treatment of advanced-stage or metastatic non-small-cell lung cancer. In this area of cancerology, meta-analyses have provided determining information demonstrating the impact of chemotherapy on patient survival. They have also helped define a two-drug regimen based on cisplatin as the gold standard treatment for patients with a satisfactory general status. Recently, the meta-analysis method was used to measure the influence of gemcitabin in combination with platinium salts and demonstrated a small but significant benefit in survival, confirming that gemcitabin remains the gold standard treatment in combination with cisplatin.