Xiao, Yuan-mei; Wang, Zhi-ming; Wang, Mian-zhen; Lan, Ya-jia
2005-06-01
To test the reliability and validity of two mental workload assessment scales, i.e. subjective workload assessment technique (SWAT) and NASA task load index (NASA-TLX). One thousand two hundred and sixty-eight mental workers were sampled from various kinds of occupations, such as scientific research, education, administration and medicine, etc, with randomized cluster sampling. The re-test reliability, split-half reliability, Cronbach's alpha coefficient and correlation coefficients between item score and total score were adopted to test the reliability. The test of validity included structure validity. The re-test reliability coefficients of these two scales and their items were ranged from 0.516 to 0.753 (P < 0.01), indicating the two scales had good re-test reliability; the split-half reliability of SWAT was 0.645, and its Cronbach's alpha coefficient was more than 0.80, all the correlation coefficients between its items score and total score were more than 0.70; as for NASA-TLX, both the split-half reliability and Cronbach's alpha coefficient were more than 0.80, the correlation coefficients between its items score and total score were all more than 0.60 (P < 0.01) except the item of performance. Both scales had good inner consistency. The Pearson correlation coefficient between the two scales was 0.492 (P < 0.01), implying the results of the two scales had good consistency. Factor analysis showed that the two scales had good structure validity. Both SWAT and NASA-TLX have good reliability and validity and may be used as a valid tool to assess mental workload in China after being revised properly.
Guo, Rongbo; Chen, Jiping; Zhang, Qing; Wu, Wenzhong; Liang, Xinmiao
2004-01-01
Using the methanol-water mixtures as mobile phases of soil column liquid chromatography (SCLC), prediction of soil adsorption coefficients (K(d)) by SCLC was validated in a wide range of soil types. The correlations between the retention factors measured by SCLC and soil adsorption coefficients measured by batch experiments were studied for five soils with different properties, i.e., Eurosoil 1#, 2#, 3#, 4# and 5#. The results show that good correlations existed between the retention factors and soil adsorption coefficients for Eurosoil 1#, 2#, 3# and 4#. For Eurosoil 5# which has a pH value of near 3, the correlation between retention factors and soil adsorption coefficients was unsatisfactory using methanol-water as mobile phase of SCLC. However, a good correlation was obtained using a methanol-buffer mixture with pH 3 as the mobile phase. This study proved that the SCLC is suitable for the prediction of soil adsorption coefficients.
Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study
Hashmi, Ali M.; Naz, Shahana; Asif, Aftab; Khawaja, Imran S.
2016-01-01
Objective: To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. Methods: After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. Results: The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. Conclusion: The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research. PMID:28083049
Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study.
Hashmi, Ali M; Naz, Shahana; Asif, Aftab; Khawaja, Imran S
2016-01-01
To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research.
The Pittsburgh Sleep Quality Index: validation of the Urdu translation.
Hashmi, Ali Madeeh; Khawaja, Imran Shuja; Butt, Zeeshan; Umair, Muhammad; Naqvi, Suhaib Haider; Jawad-Ul-Haq
2014-02-01
To translate and validate the Pittsburgh Sleep Quality Index (PSQI), a standardized self-administered questionnaire for the assessment of subjective sleep quality into the Urdu language. Validation study. Mayo Hospital, Lahore, from March to April 2012. The PSQI was translated into Urdu following standard guidelines. The final Urdu version (PSQI-U) was administered to 200 healthy volunteers comprising medical students, nursing staff and doctors. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation of component scores with global score was assessed by calculating Spearman correlation coefficient. Correlation between global PSQI-U scores at baseline with global scores for each PSQI-U and PSQI-E at 4-week interval was evaluated by calculating Spearman correlation coefficient. Moreover, scores on individual items of the scale at baseline were compared with respective scores after 4-week by t-test. One hundred and eighty five (185) participants completed the PSQI-U at baseline. The Cronbach alpha for PSQI-U was 0.56. Scores on individual components of the PSQI-U and composite scores were all highly correlated with each other (all p-values < 0.01). Composite scores for PSQI-U at baseline and PSQI-E at 4-week interval were also highly correlated with each other (Spearman correlation coefficient 0.74, p-value < 0.01) indicating good linguistic interchangeability. Composite scores for PSQI-U at baseline and at 4-week interval were positively correlated with each other (Spearman correlation coefficient 0.70, p < 0.01) indicating good test-retest reliability. The PSQI-U is a valid and reliable instrument for the assessment of sleep quality. It shows good linguistic interchangeability and test-retest reliability in comparison to the original English version when applied to individuals who speak the Urdu language. The PSQI-U can be a tool either for clinical management or research.
Oviedo-Caro, Miguel Ángel; Bueno-Antequera, Javier; Munguía-Izquierdo, Diego
2018-03-19
To transculturally adapt the Spanish version of Pregnancy Physical Activity Questionnaire (PPAQ) analyzing its psychometric properties. The PPAQ was transculturally adapted into Spanish. Test-retest reliability was evaluated in a subsample of 109 pregnant women. The validity was evaluated in a sample of 208 pregnant women who answered the questionnaire and wore the multi-sensor monitor for 7 valid days. The reliability (intraclass correlation coefficient), concordance (concordance correlation coefficient), correlation (Pearson correlation coefficient), agreement (Bland-Altman plots) and relative activity levels (Jonckheere-Terpstra test) between both administrations and methods were examined. Intraclass correlation coefficients between both administrations were good for all categories except transportation. A low but significant correlation was found for total activity (light and above) whereas no correlation was found for other intensities between both methods. Relative activity levels analysis showed a significant linear trend for increased total activity between both methods. Spanish version of PPAQ is a brief and easily interpretable questionnaire with good reliability and ability to rank individuals, and poor validity compared with multi-sensor monitor. The use of PPAQ provides information of pregnancy-specific activities in order to establish physical activity levels of pregnant women and adapt health promotion interventions. Copyright © 2018 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.
Evaluation of generalized heat-transfer coefficients in pilot AFBC units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grewal, N.S.
Experimental data for heat transfer rates as obtained in a 0.209m/sup 2/ AFBC unit at the GFETC is examined in the light of the existing four correlations for heat transfer coefficient between an immersed staggered array of horizontal tubes and a gas-solid fluidized bed. The predicted values of heat transfer coefficient from the correlations proposed by Grewal and Bansal are found to be in good agreement with the experimental values of heat transfer coefficient when the contribution due to radiation is also included.
Evaluation of generalized heat transfer coefficients in pilot AFBC units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grewal, N.S.
Experimental data for heat transfer rates as obtained in a 0.209m/sup 2/ AFBC unit at the GFETC is examined in the light of the existing four correlations for heat transfer coefficient between an immersed staggered array of horizontal tubes and a gas-solid fluidized bed. The predicted values of heat transfer coefficient from the correlations proposed by Grewal and Bansal are found to be in good agreement with the experimental values of heat transfer coefficient when the contribution due to radiation is also included.
Application of an efficient hybrid scheme for aeroelastic analysis of advanced propellers
NASA Technical Reports Server (NTRS)
Srivastava, R.; Sankar, N. L.; Reddy, T. S. R.; Huff, D. L.
1989-01-01
An efficient 3-D hybrid scheme is applied for solving Euler equations to analyze advanced propellers. The scheme treats the spanwise direction semi-explicitly and the other two directions implicitly, without affecting the accuracy, as compared to a fully implicit scheme. This leads to a reduction in computer time and memory requirement. The calculated power coefficients for two advanced propellers, SR3 and SR7L, and various advanced ratios showed good correlation with experiment. Spanwise distribution of elemental power coefficient and steady pressure coefficient differences also showed good agreement with experiment. A study of the effect of structural flexibility on the performance of the advanced propellers showed that structural deformation due to centrifugal and aero loading should be included for better correlation.
NASA Astrophysics Data System (ADS)
Zhao, Siqi; Zhang, Guanglong; Xia, Shuwei; Yu, Liangmin
2018-06-01
As a group of diversified frameworks, quinazolin derivatives displayed a broad field of biological functions, especially as anticancer. To investigate the quantitative structure-activity relationship, 3D-QSAR models were generated with 24 quinazolin scaffold molecules. The experimental and predicted pIC50 values for both training and test set compounds showed good correlation, which proved the robustness and reliability of the generated QSAR models. The most effective CoMFA and CoMSIA were obtained with correlation coefficient r 2 ncv of 1.00 (both) and leave-one-out coefficient q 2 of 0.61 and 0.59, respectively. The predictive abilities of CoMFA and CoMSIA were quite good with the predictive correlation coefficients ( r 2 pred ) of 0.97 and 0.91. In addition, the statistic results of CoMFA and CoMSIA were used to design new quinazolin molecules.
NASA Astrophysics Data System (ADS)
Ahn, Hyunjun; Jung, Younghun; Om, Ju-Seong; Heo, Jun-Haeng
2014-05-01
It is very important to select the probability distribution in Statistical hydrology. Goodness of fit test is a statistical method that selects an appropriate probability model for a given data. The probability plot correlation coefficient (PPCC) test as one of the goodness of fit tests was originally developed for normal distribution. Since then, this test has been widely applied to other probability models. The PPCC test is known as one of the best goodness of fit test because it shows higher rejection powers among them. In this study, we focus on the PPCC tests for the GEV distribution which is widely used in the world. For the GEV model, several plotting position formulas are suggested. However, the PPCC statistics are derived only for the plotting position formulas (Goel and De, In-na and Nguyen, and Kim et al.) in which the skewness coefficient (or shape parameter) are included. And then the regression equations are derived as a function of the shape parameter and sample size for a given significance level. In addition, the rejection powers of these formulas are compared using Monte-Carlo simulation. Keywords: Goodness-of-fit test, Probability plot correlation coefficient test, Plotting position, Monte-Carlo Simulation ACKNOWLEDGEMENTS This research was supported by a grant 'Establishing Active Disaster Management System of Flood Control Structures by using 3D BIM Technique' [NEMA-12-NH-57] from the Natural Hazard Mitigation Research Group, National Emergency Management Agency of Korea.
Virial Coefficients for the Liquid Argon
NASA Astrophysics Data System (ADS)
Korth, Micheal; Kim, Saesun
2014-03-01
We begin with a geometric model of hard colliding spheres and calculate probability densities in an iterative sequence of calculations that lead to the pair correlation function. The model is based on a kinetic theory approach developed by Shinomoto, to which we added an interatomic potential for argon based on the model from Aziz. From values of the pair correlation function at various values of density, we were able to find viral coefficients of liquid argon. The low order coefficients are in good agreement with theoretical hard sphere coefficients, but appropriate data for argon to which these results might be compared is difficult to find.
Semimajor Axis Estimation Strategies
NASA Technical Reports Server (NTRS)
How, Jonathan P.; Alfriend, Kyle T.; Breger, Louis; Mitchell, Megan
2004-01-01
This paper extends previous analysis on the impact of sensing noise for the navigation and control aspects of formation flying spacecraft. We analyze the use of Carrier-phase Differential GPS (CDGPS) in relative navigation filters, with a particular focus on the filter correlation coefficient. This work was motivated by previous publications which suggested that a "good" navigation filter would have a strong correlation (i.e., coefficient near -1) to reduce the semimajor axis (SMA) error, and therefore, the overall fuel use. However, practical experience with CDGPS-based filters has shown this strong correlation seldom occurs (typical correlations approx. -0.1), even when the estimation accuracies are very good. We derive an analytic estimate of the filter correlation coefficient and demonstrate that, for the process and sensor noises levels expected with CDGPS, the expected value will be very low. It is also demonstrated that this correlation can be improved by increasing the time step of the discrete Kalman filter, but since the balance condition is not satisfied, the SMA error also increases. These observations are verified with several linear simulations. The combination of these simulations and analysis provide new insights on the crucial role of the process noise in determining the semimajor axis knowledge.
Richter, Jörg
2015-04-01
Methods to assess intervention progress and outcome for frequent use are needed. To provide preliminary information about psychometric properties for the Norwegian version of the Brief Problems Monitor. Cronbach's alpha scores and intra-class correlation coefficients as indicators for internal consistency (reliability) and Pearson correlation coefficients between corresponding subscales of the long and short ASEBA form versions as well as multiple regression coefficients to explore the predictive power of the reduced item-set related to the corresponding scale-scores of the long version were calculated in large, representative data sets of Norwegian children and adolescents. Cronbach's alpha scores of the Norwegian version of the BPM subscales varied between 0.67 (attention BPM-youth) and 0.88 (attention BPM-teacher) and between 0.90 (BPM-youth) and 0.96 (BPM-teacher) for its total problem score. Corresponding subscales from the long versions and the BPM as well as the total problems scores were closely correlated with coefficients of high effect size (all r > 0.80). The variance of the items of the BPM explained about three-quarters or more of the variance in the corresponding subscales of the long version. The Norwegian BPM has good psychometric properties in terms of 1) being acceptable to good internal consistency and in terms of 2) regression coefficients of high effect size from the BPM items to the problem-scale scores of the long versions as validity indicators. Its use in clinical practice and research can be recommended.
Bogun, Frank; Taj, Majid; Ting, Michael; Kim, Hyungjin Myra; Reich, Stephen; Good, Eric; Jongnarangsin, Krit; Chugh, Aman; Pelosi, Frank; Oral, Hakan; Morady, Fred
2008-03-01
Pace mapping has been used to identify the site of origin of focal ventricular arrhythmias. The spatial resolution of pace mapping has not been adequately quantified using currently available three-dimensional mapping systems. The purpose of this study was to determine the spatial resolution of pace mapping in patients with idiopathic ventricular tachycardia or premature ventricular contractions originating in the right ventricular outflow tract. In 16 patients with idiopathic ventricular tachycardia/ectopy from the right ventricular outflow tract, comparisons and classifications of pace maps were performed by two observers (good pace map: match >10/12 leads; inadequate pace map: match < or =10/12 leads) and a customized MATLAB 6.0 program (assessing correlation coefficient and normalized root mean square of the difference (nRMSd) between test and template signals). With an electroanatomic mapping system, the correlation coefficient of each pace map was correlated with the distance between the pacing site and the effective ablation site. The endocardial area within the 10-ms activation isochrone was measured. The ablation procedure was effective in all patients. Sites with good pace maps had a higher correlation coefficient and lower nRMSd than sites with inadequate pace maps (correlation coefficient: 0.96 +/- 0.03 vs 0.76 +/- 0.18, P <.0001; nRMSd: 0.41 +/- 0.16 vs 0.89 +/- 0.39, P <.0001). Using receiver operating characteristic curves, appropriate cutoff values were >0.94 for correlation coefficient (sensitivity 81%, specificity 89%) and < or =0.54 for nRMSd (sensitivity 76%, specificity 80%). Good pace maps were located a mean of 7.3 +/- 5.0 mm from the effective ablation site and had a mean activation time of -24 +/- 7 ms. However, in 3 (18%) of 16 patients, the best pace map was inadequate at the effective ablation site, with an endocardial activation time at these sites of -25 +/- 12 ms. Pace maps with correlation coefficient > or =0.94 were confined to an area of 1.8 +/- 0.6 cm2. The 10-ms isochrone measured 1.2 +/- 0.7 cm2. The spatial resolution of a good pace map for targeting ventricular tachycardia/ectopy is 1.8 cm2 in the right ventricular outflow tract and therefore is inferior to the spatial resolution of activation mapping as assessed by isochronal activation. In approximately 20% of patients, pace mapping is unreliable in identifying the site of origin, possibly due a deeper site of origin and preferential conduction via fibers connecting the focus to the endocardial surface.
Shipley, Hilary; Guedes, Alonso; Graham, Lynelle; Goudie-DeAngelis, Elizabeth; Wendt-Hornickle, Erin
2018-05-01
Objectives The objective of this study was to determine the inter-rater reliability and convergent validity of the Colorado State University Feline Acute Pain Scale (CSU-FAPS) in a preliminary appraisal of its performance in a clinical teaching setting. Methods Sixty-eight female cats were assessed for pain after ovariohysterectomy. A cohort of 21 cats was examined independently by four raters (two board-certified anesthesiologists and two anesthesia residents) with the CSU-FAPS, and intra-class correlation coefficient (ICC) was used to determine inter-rater reliability. Weighted Cohen's kappa was used to determine inter-rater reliability centered on the 'need to reassess analgesic plan' (dichotomous scale). A separate cohort of 47 cats was evaluated independently by two raters (one board-certified anesthesiologist and one veterinary small animal rotating intern) using the CSU-FAPS and the Glasgow Composite Measure Pain Scale (CMPS-Feline), and Spearman rank-order correlation was determined to assess convergent validity. Reliability was interpreted using Altman's classification as very good, good, moderate, fair and poor. Validity was considered adequate if correlation coefficients were between 0.4 and 0.8. Results The ICC was 0.61 for anesthesiologists and 0.67 for residents, indicating good reliability. Weighted Cohen's kappa was 0.79 for anesthesiologists and 0.44 for residents, indicating moderate to good reliability. The Spearman rank correlation indicated a statistically significant ( P = 0.0003) positive correlation (0.31; 95% confidence interval 0.14-0.46) between the CSU-FAPS and the CMPS-Feline. Conclusions and relevance The CSU-FAPS showed moderate-to-good inter-rater reliability when used by veterinarians to assess pain level or need to reassess analgesic plan after ovariohysterectomy in cats. The validity fell short of current guidelines for correlation coefficients and further refinement and testing are warranted to improve its performance.
Evaluation of icing drag coefficient correlations applied to iced propeller performance prediction
NASA Technical Reports Server (NTRS)
Miller, Thomas L.; Shaw, R. J.; Korkan, K. D.
1987-01-01
Evaluation of three empirical icing drag coefficient correlations is accomplished through application to a set of propeller icing data. The various correlations represent the best means currently available for relating drag rise to various flight and atmospheric conditions for both fixed-wing and rotating airfoils, and the work presented here ilustrates and evaluates one such application of the latter case. The origins of each of the correlations are discussed, and their apparent capabilities and limitations are summarized. These correlations have been made to be an integral part of a computer code, ICEPERF, which has been designed to calculate iced propeller performance. Comparison with experimental propeller icing data shows generally good agreement, with the quality of the predicted results seen to be directly related to the radial icing extent of each case. The code's capability to properly predict thrust coefficient, power coefficient, and propeller efficiency is shown to be strongly dependent on the choice of correlation selected, as well as upon proper specificatioon of radial icing extent.
NASA Technical Reports Server (NTRS)
Crooker, N. U.; Siscoe, G. L.; Russell, C. T.; Smith, E. J.
1982-01-01
Correlation variability between ISEE 1 and 3 IMF measurements is investigated, and factors governing the variability are discussed. About 200 two-hour periods when correlation was good, and 200 when correlation was poor, are examined, and both IMF variance and spacecraft separation distance in the plane perpendicular to the earth-sun line exert substantial control. The scale size of magnetic features is larger when variance is high, and abrupt changes in the correlation coefficient from poor to good or good to poor in adjacent two-hour intervals appear to be governed by the sense of change of IMF variance and vice versa. During periods of low variance, good correlations are most likely to occur when the distance between ISEE 1 and 3 perpendicular to the IMF is less than 20 earth radii.
NASA Astrophysics Data System (ADS)
Piretzidis, D.; Sra, G.; Sideris, M. G.
2016-12-01
This study explores new methods for identifying correlation errors in harmonic coefficients derived from monthly solutions of the Gravity Recovery and Climate Experiment (GRACE) satellite mission using pattern recognition and neural network algorithms. These correlation errors are evidenced in the differences between monthly solutions and can be suppressed using a de-correlation filter. In all studies so far, the implementation of the de-correlation filter starts from a specific minimum order (i.e., 11 for RL04 and 38 for RL05) until the maximum order of the monthly solution examined. This implementation method has two disadvantages, namely, the omission of filtering correlated coefficients of order less than the minimum order and the filtering of uncorrelated coefficients of order higher than the minimum order. In the first case, the filtered solution is not completely free of correlated errors, whereas the second case results in a monthly solution that suffers from loss of geophysical signal. In the present study, a new method of implementing the de-correlation filter is suggested, by identifying and filtering only the coefficients that show indications of high correlation. Several numerical and geometric properties of the harmonic coefficient series of all orders are examined. Extreme cases of both correlated and uncorrelated coefficients are selected, and their corresponding properties are used to train a two-layer feed-forward neural network. The objective of the neural network is to identify and quantify the correlation by providing the probability of an order of coefficients to be correlated. Results show good performance of the neural network, both in the validation stage of the training procedure and in the subsequent use of the trained network to classify independent coefficients. The neural network is also capable of identifying correlated coefficients even when a small number of training samples and neurons are used (e.g.,100 and 10, respectively).
Estimation of soil-soil solution distribution coefficient of radiostrontium using soil properties.
Ishikawa, Nao K; Uchida, Shigeo; Tagami, Keiko
2009-02-01
We propose a new approach for estimation of soil-soil solution distribution coefficient (K(d)) of radiostrontium using some selected soil properties. We used 142 Japanese agricultural soil samples (35 Andosol, 25 Cambisol, 77 Fluvisol, and 5 others) for which Sr-K(d) values had been determined by a batch sorption test and listed in our database. Spearman's rank correlation test was carried out to investigate correlations between Sr-K(d) values and soil properties. Electrical conductivity and water soluble Ca had good correlations with Sr-K(d) values for all soil groups. Then, we found a high correlation between the ratio of exchangeable Ca to Ca concentration in water soluble fraction and Sr-K(d) values with correlation coefficient R=0.72. This pointed us toward a relatively easy way to estimate Sr-K(d) values.
The Association Between Self-Rated Fitness and Cardiorespiratory Fitness in Adults.
Jensen, Karina Gregersen; Rosthøj, Susanne; Linneberg, Allan; Aadahl, Mette
2018-06-01
To assess criterion validity of a single item question on self-rated physical fitness against objectively measured cardiorespiratory fitness. From the Health2008 study 749 men and women between 30 and 60 years of age rated their fitness as excellent, very good, good, fair or poor. Cardiorespiratory fitness was estimated with the watt-max test. Agreement between self-rated and objectively measured physical fitness was assessed by Cohen's weighted kappa coefficient. Correlation was determined by Goodman & Kruskal's gamma correlation coefficient. All analyses were stratified according to gender. Data from 323 men and 426 women were analysed. There was a slight agreement between self-rated and objectively measured fitness in men (weighted kappa: 0.18, [95%CI: 0.13;0.23]) and a fair agreement in women (weighted kappa: 0.27, [95%CI: 0.22;0.32]). In both genders, self-rated fitness was positively correlated with objectively measured fitness (moderate correlation; gamma correlation coefficient for men: 0.63 [95%CI: 0.54;0.72] and women: 0.67 [95%CI: 0.59;0.75]). There was a slight to fair agreement and moderate, positive correlations between self-rated physical fitness and watt-max estimated cardiorespiratory fitness. Hence, a single-item question on physical fitness may be a cost-effective method of assessing fitness in large population studies, but is not valid for individual assessments. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Technical Reports Server (NTRS)
Guiot, R.; Wunnenberg, H.
1980-01-01
The methods by which aerodynamic coefficients are determined and discussed. These include: calculations, wind tunnel experiments and experiments in flight for various prototypes of the Alpha Jet. A comparison of obtained results shows good correlation between expectations and in-flight test results.
Psychometric properties of the Exercise Benefits/Barriers Scale in Mexican elderly women
Enríquez-Reyna, María Cristina; Cruz-Castruita, Rosa María; Ceballos-Gurrola, Oswaldo; García-Cadena, Cirilo Humberto; Hernández-Cortés, Perla Lizeth; Guevara-Valtier, Milton Carlos
2017-01-01
ABSTRACT Objective: analyze and assess the psychometric properties of the subscales in the Spanish version of the Exercise Benefits/Barriers Scale in an elderly population in the Northeast of Mexico. Method: methodological study. The sample consisted of 329 elderly associated with one of the five public centers for senior citizens in the metropolitan area of Northeast Mexico. The psychometric properties included the assessment of the Cronbach's alpha coefficient, the Kaiser Meyer Olkin coefficient, the inter-item correlation, exploratory and confirmatory factor analysis. Results: in the principal components analysis, two components were identified based on the 43 items in the scale. The item-total correlation coefficient of the exercise benefits subscale was good. Nevertheless, the coefficient for the exercise barriers subscale revealed inconsistencies. The reliability and validity were acceptable. The confirmatory factor analysis revealed that the elimination of items improved the goodness of fit of the baseline scale, without affecting its validity or reliability. Conclusion: the Exercise Benefits/Barriers subscale presented satisfactory psychometric properties for the Mexican context. A 15-item short version is presented with factorial structure, validity and reliability similar to the complete scale. PMID:28591306
Georgieva-Zhostova, Spaska; Kolev, Ognyan I; Stambolieva, Katerina
2014-09-01
The aim of the present study was the translation, cross-cultural adaptation and validation of the Dizziness Handicap Inventory in Bulgarian language (DHI-BG). Ninety-seven vestibular patients (19 men and 78 women, mean age 45.08 ± 13.85 years) took part in the investigation. All participants were asked to fill in the DHI-BG. Internal consistency was estimated using Cronbach's alpha and item-total correlation, reproducibility by calculating Bland-Altman's limits of agreement and intraclass correlation coefficients (ICCs). Associations were estimated by Spearman's correlation coefficients. The Cronbach's alpha for the total score, functional, physical and emotional subscales of DHI-BG were 0.88, 0.75, 0.72 and 0.81. The floor and ceiling effects of the DHI-BG total scale were evaluated with respect to the limits of agreement which were ±9.4-14.53 points. Intraclass correlation coefficients (ICCs) for all scale and subscales were higher than the recommended value of 0.75 and determined good test-retest reliability. The range of items correlation for DHI-BG was from 0.27 (item 12) to 0.72 (item 3). No significant differences were observed in the Cronbach's alpha coefficients between the DHI-BG and the original version, the German and Italian versions of the questionnaire. The most significant difference was observed in comparison with the German version of DHI. Construct validity presented a moderate correlation between Romberg coefficients and DHI-BG scores and strong correlation between all scores of DHI and the self-perceived disability. The results suggest that DHI-BG scores show a good discriminative validity between groups with different levels of self-assessed disability. The Bulgarian version of the DHI is a reliable and valid tool in assessing the impact of dizziness on the quality of life in Bulgarian vestibular patients.
Flosadottir, Vala; Roos, Ewa M; Ageberg, Eva
2017-09-01
The Activity Rating Scale (ARS) for disorders of the knee evaluates the level of activity by the frequency of participation in 4 separate activities with high demands on knee function, with a score ranging from 0 (none) to 16 (pivoting activities 4 times/wk). To translate and cross-culturally adapt the ARS into Swedish and to assess measurement properties of the Swedish version of the ARS. Cohort study (diagnosis); Level of evidence, 2. The COSMIN guidelines were followed. Participants (N = 100 [55 women]; mean age, 27 years) who were undergoing rehabilitation for a knee injury completed the ARS twice for test-retest reliability. The Knee injury and Osteoarthritis Outcome Score (KOOS), Tegner Activity Scale (TAS), and modernized Saltin-Grimby Physical Activity Level Scale (SGPALS) were administered at baseline to validate the ARS. Construct validity and responsiveness of the ARS were evaluated by testing predefined hypotheses regarding correlations between the ARS, KOOS, TAS, and SGPALS. The Cronbach alpha, intraclass correlation coefficients, absolute reliability, standard error of measurement, smallest detectable change, and Spearman rank-order correlation coefficients were calculated. The ARS showed good internal consistency (α ≈ 0.96), good test-retest reliability (intraclass correlation coefficient >0.9), and no systematic bias between measurements. The standard error of measurement was less than 2 points, and the smallest detectable change was less than 1 point at the group level and less than 5 points at the individual level. More than 75% of the hypotheses were confirmed, indicating good construct validity and good responsiveness of the ARS. The Swedish version of the ARS is valid, reliable, and responsive for evaluating the level of activity based on the frequency of participation in high-demand knee sports activities in young adults with a knee injury.
Koritar, Priscila; Philippi, Sonia Tucunduva; Alvarenga, Marle dos Santos; Santos, Bernardo dos
2014-08-01
The scope of this study was to show the cross-cultural adaptation and validation of the Health and Taste Attitude Scale in Portuguese. The methodology included translation of the scale; evaluation of conceptual, operational and item-based equivalence by 14 experts and 51 female undergraduates; semantic equivalence and measurement assessment by 12 bilingual women by the paired t-test, the Pearson correlation coefficient and the coefficient intraclass correlation; internal consistency and test-retest reliability by Cronbach's alpha and intraclass correlation coefficient, respectively, after application on 216 female undergraduates; assessment of discriminant and concurrent validity via the t-test and Spearman's correlation coefficient, respectively, in addition to Confirmatory Factor and Exploratory Factor Analysis. The scale was considered adequate and easily understood by the experts and university students and presented good internal consistency and reliability (µ 0.86, ICC 0.84). The results show that the scale is valid and can be used in studies with women to better understand attitudes related to taste.
Astray, G; Soto, B; Lopez, D; Iglesias, M A; Mejuto, J C
2016-01-01
Transit data analysis and artificial neural networks (ANNs) have proven to be a useful tool for characterizing and modelling non-linear hydrological processes. In this paper, these methods have been used to characterize and to predict the discharge of Lor River (North Western Spain), 1, 2 and 3 days ahead. Transit data analyses show a coefficient of correlation of 0.53 for a lag between precipitation and discharge of 1 day. On the other hand, temperature and discharge has a negative coefficient of correlation (-0.43) for a delay of 19 days. The ANNs developed provide a good result for the validation period, with R(2) between 0.92 and 0.80. Furthermore, these prediction models have been tested with discharge data from a period 16 years later. Results of this testing period also show a good correlation, with R(2) between 0.91 and 0.64. Overall, results indicate that ANNs are a good tool to predict river discharge with a small number of input variables.
Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano
2017-01-01
To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent.
Bauer, Katharina Christin; Hämmerling, Frank; Kittelmann, Jörg; Dürr, Cathrin; Görlich, Fabian; Hubbuch, Jürgen
2017-04-01
Information about protein-protein interactions provides valuable knowledge about the phase behavior of protein solutions during the biopharmaceutical production process. Up to date it is possible to capture their overall impact by an experimentally determined potential of mean force. For the description of this potential, the second virial coefficient B22, the diffusion interaction parameter kD, the storage modulus G', or the diffusion coefficient D is applied. In silico methods do not only have the potential to predict these parameters, but also to provide deeper understanding of the molecular origin of the protein-protein interactions by correlating the data to the protein's three-dimensional structure. This methodology furthermore allows a lower sample consumption and less experimental effort. Of all in silico methods, QSAR modeling, which correlates the properties of the molecule's structure with the experimental behavior, seems to be particularly suitable for this purpose. To verify this, the study reported here dealt with the determination of a QSAR model for the diffusion coefficient of proteins. This model consisted of diffusion coefficients for six different model proteins at various pH values and NaCl concentrations. The generated QSAR model showed a good correlation between experimental and predicted data with a coefficient of determination R2 = 0.9 and a good predictability for an external test set with R2 = 0.91. The information about the properties affecting protein-protein interactions present in solution was in agreement with experiment and theory. Furthermore, the model was able to give a more detailed picture of the protein properties influencing the diffusion coefficient and the acting protein-protein interactions. Biotechnol. Bioeng. 2017;114: 821-831. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Ashmore, Alexander M; Gozzard, Charles; Blewitt, Neil
2007-01-01
The Liverpool Elbow Score (LES) is a newly developed, validated elbow-specific score. It consists of a patient-answered questionnaire (PAQ) and a clinical assessment. The purpose of this study was to determine whether the PAQ portion of the LES could be used independently as a postal questionnaire for the assessment of outcome after total elbow arthroplasty and to correlate the LES and the Mayo Elbow Performance Score (MEPS). A series of 51 total elbow replacements were reviewed by postal questionnaire. Patients then attended the clinic for assessment by use of both the LES and the MEPS. There was an excellent response rate to the postal questionnaire (98%), and 44 elbows were available for clinical review. Good correlation was shown between the LES and the MEPS (Spearman correlation coefficient, 0.84; P < .001) and between the PAQ portion of the LES and the MEPS (Spearman correlation coefficient, 0.76; P < .001). We conclude that there is good correlation between the LES PAQ component and the MEPS, suggesting that outcome assessment is possible by postal questionnaire.
Establishment of a Simple and Convenient Method for Folic Acid Enzyme Chemiluminescence Immunoassay
NASA Astrophysics Data System (ADS)
Liu, Ting; Zeng, Ling; Yu, Zhengwei; Yang, Yanfei; Qu, Yunhuan
2018-01-01
The enzyme chemiluminescence new immunoassay for folic acid (FA) was established by competition model. Add FA samples to a microtiter plate precoated with the goat anti-mouse IgG firstly, then add enzyme abled FA and FA monoclonal antibody (McAb). The values of CLIA were measured to reflect the quantity of FA. The limit of detection(LOD) of assay is 0.37ng/mL. The assay shows good correlation during 1∼30 ng/mL with correlation coefficient 0.9976. The intra- and inter-assay coefficients of variation are 4.8 % ∼ 7.3 % and 6.1 % ∼ 12.2 %, respectively. The recovery of folic acid in serum is 90.4 %∼113.2 %. Compared with determine value clinically in chemiluminescence immunoassay kit from Roche company, the correlative equation is y = 0.9689x + 0.0228, and correlation coefficient is 0.9780. Various components and kit overall show good stabilities. This method is simple and convenient, and has low LOD value. The method has overcome the shortcomings of the present references. It is easy to apply and has broad clinical application prospect. It lays an experimental foundation for the preparation of Mc Ab against folic acid and the development of domestic kit.
Serinelli, Serenella; Panebianco, Valeria; Martino, Milvia; Battisti, Sofia; Rodacki, Karina; Marinelli, Enrico; Zaccagna, Fulvio; Semelka, Richard C; Tomei, Ernesto
2015-05-01
In forensic practice, there is a growing need for accurate methods of age estimation, especially in the cases of young individuals of unknown age. Age can be estimated through somatic features that are universally considered associated with chronological age. Unfortunately, these features do not always coincide with the real chronological age: for these reasons that age determination is often very difficult. Our aim is to evaluate accuracy of skeletal age estimation using Tomei's MRI method in subjects between 12 and 19 years old for forensic purposes. Two investigators analyzed MRI images of the left hand and wrist of 77 male and 74 female caucasian subjects, without chronic diseases or developmental disorders, whose age ranged from 12 to 19 years. Skeletal maturation was determined by two operators, who analyzed all MRI images separately, in blinded fashion to the chronological age. Inter-rater agreement was measured with Pearson (R (2)) coefficient. One of the examiners repeated the evaluation after 6 months, and intraobserver variation was analyzed. Bland-Altman plots were used to determine mean differences between skeletal and chronological age. Inter-rater agreement Pearson coefficient showed a good linear correlation, respectively, 0.98 and 0.97 in males and females. Bland-Altman analysis demonstrated that the differences between chronological and skeletal age are not significant. Spearman's correlation coefficient showed good correlation between skeletal and chronological age both in females (R (2) = 0.96) and in males (R (2) = 0.94). Our results show that MRI skeletal age is a reproducible method and has good correlation with chronological age.
Clinical applications of correlational vestibular autorotation test.
Hsieh, Li-Chun; Lin, Te-Ming; Chang, Yu-Min; Kuo, Terry B J; Lee, Gho-She
2015-06-01
The correlational vestibular autorotation test (VAT) system has the advantages of good test-retest reliability and calibrations of absolute degrees of eye movement are unnecessary when acquiring a cross correlation coefficient (CCC). The approach is able to efficiently detect peripheral vestibulopathies. A VAT has some drawbacks including poor test-retest reliability and slippage of sensor. This study aimed to develop a correlational VAT system and to evaluate the reliability and applicability of this system. Twenty healthy participants and 10 vertiginous patients were enrolled. Vertical and horizontal autorotations from 0 to 3 Hz with either closed or open eyes were performed. A small sensor and a wireless transmission technique were used to acquire the electro-ocular graph and head velocity signals. The two signals were analyzed using CCCs to assess the functioning of the vestibular ocular reflex (VOR). The results showed a significantly greater CCC for open-eye versus closed-eye of head autorotations. The CCCs also increased significantly with head rotational frequencies. Moreover, the CCCs significantly correlated with the VOR gains at autorotation frequencies ≥1.0 Hz. The test-retest reliability was good (intraclass correlation coefficients ≥0.85). The vertiginous participants had significantly lower individual CCCs and overall average CCC than age- and-gender matched controls.
Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano
2017-01-01
Objective To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). Materials and methods In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. Results The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). Conclusion CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent. PMID:28894329
NASA Astrophysics Data System (ADS)
Mitra, Ashis; Majumdar, Prabal Kumar; Bannerjee, Debamalya
2013-03-01
This paper presents a comparative analysis of two modeling methodologies for the prediction of air permeability of plain woven handloom cotton fabrics. Four basic fabric constructional parameters namely ends per inch, picks per inch, warp count and weft count have been used as inputs for artificial neural network (ANN) and regression models. Out of the four regression models tried, interaction model showed very good prediction performance with a meager mean absolute error of 2.017 %. However, ANN models demonstrated superiority over the regression models both in terms of correlation coefficient and mean absolute error. The ANN model with 10 nodes in the single hidden layer showed very good correlation coefficient of 0.982 and 0.929 and mean absolute error of only 0.923 and 2.043 % for training and testing data respectively.
Comparison between uroflowmetry and sonouroflowmetry in recording of urinary flow in healthy men.
Krhut, Jan; Gärtner, Marcel; Sýkora, Radek; Hurtík, Petr; Burda, Michal; Luňáček, Libor; Zvarová, Katarína; Zvara, Peter
2015-08-01
To evaluate the accuracy of sonouroflowmetry in recording urinary flow parameters and voided volume. A total of 25 healthy male volunteers (age 18-63 years) were included in the study. All participants were asked to carry out uroflowmetry synchronous with recording of the sound generated by the urine stream hitting the water level in the urine collection receptacle, using a dedicated cell phone. From 188 recordings, 34 were excluded, because of voided volume <150 mL or technical problems during recording. Sonouroflowmetry recording was visualized in a form of a trace, representing sound intensity over time. Subsequently, the matching datasets of uroflowmetry and sonouroflowmetry were compared with respect to flow time, voided volume, maximum flow rate and average flow rate. Pearson's correlation coefficient was used to compare parameters recorded by uroflowmetry with those calculated based on sonouroflowmetry recordings. The flow pattern recorded by sonouroflowmetry showed a good correlation with the uroflowmetry trace. A strong correlation (Pearson's correlation coefficient 0.87) was documented between uroflowmetry-recorded flow time and duration of the sound signal recorded with sonouroflowmetry. A moderate correlation was observed in voided volume (Pearson's correlation coefficient 0.68) and average flow rate (Pearson's correlation coefficient 0.57). A weak correlation (Pearson's correlation coefficient 0.38) between maximum flow rate recorded using uroflowmetry and sonouroflowmetry-recorded peak sound intensity was documented. The present study shows that the basic concept utilizing sound analysis for estimation of urinary flow parameters and voided volume is valid. However, further development of this technology and standardization of recording algorithm are required. © 2015 The Japanese Urological Association.
Flosadottir, Vala; Roos, Ewa M.; Ageberg, Eva
2017-01-01
Background: The Activity Rating Scale (ARS) for disorders of the knee evaluates the level of activity by the frequency of participation in 4 separate activities with high demands on knee function, with a score ranging from 0 (none) to 16 (pivoting activities 4 times/wk). Purpose: To translate and cross-culturally adapt the ARS into Swedish and to assess measurement properties of the Swedish version of the ARS. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The COSMIN guidelines were followed. Participants (N = 100 [55 women]; mean age, 27 years) who were undergoing rehabilitation for a knee injury completed the ARS twice for test-retest reliability. The Knee injury and Osteoarthritis Outcome Score (KOOS), Tegner Activity Scale (TAS), and modernized Saltin-Grimby Physical Activity Level Scale (SGPALS) were administered at baseline to validate the ARS. Construct validity and responsiveness of the ARS were evaluated by testing predefined hypotheses regarding correlations between the ARS, KOOS, TAS, and SGPALS. The Cronbach alpha, intraclass correlation coefficients, absolute reliability, standard error of measurement, smallest detectable change, and Spearman rank-order correlation coefficients were calculated. Results: The ARS showed good internal consistency (α ≈ 0.96), good test-retest reliability (intraclass correlation coefficient >0.9), and no systematic bias between measurements. The standard error of measurement was less than 2 points, and the smallest detectable change was less than 1 point at the group level and less than 5 points at the individual level. More than 75% of the hypotheses were confirmed, indicating good construct validity and good responsiveness of the ARS. Conclusion: The Swedish version of the ARS is valid, reliable, and responsive for evaluating the level of activity based on the frequency of participation in high-demand knee sports activities in young adults with a knee injury. PMID:28979920
Statistical hypothesis tests of some micrometeorological observations
DOE Office of Scientific and Technical Information (OSTI.GOV)
SethuRaman, S.; Tichler, J.
Chi-square goodness-of-fit is used to test the hypothesis that the medium scale of turbulence in the atmospheric surface layer is normally distributed. Coefficients of skewness and excess are computed from the data. If the data are not normal, these coefficients are used in Edgeworth's asymptotic expansion of Gram-Charlier series to determine an altrnate probability density function. The observed data are then compared with the modified probability densities and the new chi-square values computed.Seventy percent of the data analyzed was either normal or approximatley normal. The coefficient of skewness g/sub 1/ has a good correlation with the chi-square values. Events withmore » vertical-barg/sub 1/vertical-bar<0.21 were normal to begin with and those with 0.21« less
Different hip and knee priority score systems: are they good for the same thing?
Escobar, Antonio; Quintana, Jose Maria; Espallargues, Mireia; Allepuz, Alejandro; Ibañez, Berta
2010-10-01
The aim of the present study was to compare two priority tools used for joint replacement for patients on waiting lists, which use two different methods. Two prioritization tools developed and validated by different methodologies were used on the same cohort of patients. The first, an IRYSS hip and knee priority score (IHKPS) developed by RAND method, was applied while patients were on the waiting list. The other, a Catalonia hip-knee priority score (CHKPS) developed by conjoint analysis, was adapted and applied retrospectively. In addition, all patients fulfilled pre-intervention the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Correlation between them was studied by Pearson correlation coefficient (r). Agreement was analysed by means of intra-class correlation coefficient (ICC), Kendall coefficient and Cohern kappa. The relationship between IHKPS, CHKPS and baseline WOMAC scores by r coefficient was studied. The sample consisted of 774 consecutive patients. Pearson correlation coefficient between IHKPS and CHKPS was 0.79. The agreement study showed that ICC was 0.74, Kendall coefficient 0.86 and kappa 0.66. Finally, correlation between CHKPS and baseline WOMAC ranged from 0.43 to 0.64. The results according to the relationship between IHKPS and WOMAC ranged from 0.50 to 0.74. Results support the hypothesis that if the final objective of the prioritization tools is to organize and sort patients on the waiting list, although they use different methodologies, the results are similar. © 2010 Blackwell Publishing Ltd.
[Dental arch form reverting by four-point method].
Pan, Xiao-Gang; Qian, Yu-Fen; Weng, Si-En; Feng, Qi-Ping; Yu, Quan
2008-04-01
To explore a simple method of reverting individual dental arch form template for wire bending. Individual dental arch form was reverted by four-point method. By defining central point of bracket on bilateral lower second premolar and first molar, certain individual dental arch form could be generated. The arch form generating procedure was then be developed to computer software for printing arch form. Four-point method arch form was evaluated by comparing with direct model measurement on linear and angular parameters. The accuracy and reproducibility were assessed by paired t test and concordance correlation coefficient with Medcalc 9.3 software package. The arch form by four-point method was of good accuracy and reproducibility (linear concordance correlation coefficient was 0.9909 and angular concordance correlation coefficient was 0.8419). The dental arch form reverted by four-point method could reproduce the individual dental arch form.
NASA Astrophysics Data System (ADS)
Zhai, Mengting; Chen, Yan; Li, Jing; Zhou, Jun
2017-12-01
The molecular electrongativity distance vector (MEDV-13) was used to describe the molecular structure of benzyl ether diamidine derivatives in this paper, Based on MEDV-13, The three-parameter (M 3, M 15, M 47) QSAR model of insecticidal activity (pIC 50) for 60 benzyl ether diamidine derivatives was constructed by leaps-and-bounds regression (LBR) . The traditional correlation coefficient (R) and the cross-validation correlation coefficient (R CV ) were 0.975 and 0.971, respectively. The robustness of the regression model was validated by Jackknife method, the correlation coefficient R were between 0.971 and 0.983. Meanwhile, the independent variables in the model were tested to be no autocorrelation. The regression results indicate that the model has good robust and predictive capabilities. The research would provide theoretical guidance for the development of new generation of anti African trypanosomiasis drugs with efficiency and low toxicity.
Leite, Priscilla Lourenço; Filomensky, Tatiana Zambrano; Black, Donald W; Silva, Adriana Cardoso
2014-08-01
The Yale-Brown Obsessive Compulsive Scale-Shopping Version (YBOCS-SV) is considered the gold standard in the assessment of shopping severity. It is designed to assess cognitions and behaviors relating to compulsive buying behavior. The present study aims to assess the validity of the Brazilian version of this scale. For the study, composed the sample 610 participants: 588 subjects of a general population and 22 compulsive buyers. Factorial analysis was performed to assess the relations and the correlation between the YBOCS-SV, the Compulsive Buying Scale (CBS), and Richmond Compulsive Buying Scale (RCBS), was assessed using Pearson coefficient, for study of convergent and divergent validity. Cronbach's alpha coefficients were used to assess internal consistency. The results show good to excellent psychometric parameters for the YBOCS-SV in its Brazilian version. With regard to correlations, the YBOCS-SV is inversely and proportionally correlated with CBS and the RCBS, indicating that the YBOCS-SV is an excellent instrument for screening compulsive buying. The YBOCS-SV presented high alpha coefficient of Cronbach's alpha (0.92), demonstrating good reliability. The Brazilian version of the YBOCS-SV is indicated to diagnose compulsive buying disorder, and likely use for the purposes intended in the Brazilian population. Copyright © 2014 Elsevier Inc. All rights reserved.
Assessment of a solid-phase reagent for urinary specific gravity determination.
Chu, S Y; Sparks, D
1984-02-01
We have compared the specific gravity (S.G.) determined by the N-Multistix method with that obtained from the Total Solids (TS) meter. Overall, 88.7% of the specific gravity results obtained with the reagent strip method were within 0.005 of those obtained with the TS meter. There was a good correlation between the methods and there was no bias for the group means obtained by either method. A good correlation was also found between the S.G. on the strip and osmolality (correlation coefficient of 0.955). The results obtained with the reagent strip for urinary specific gravity therefore appear acceptable for routine laboratory purposes.
Midwest Structural Sciences Center 2009 Annual Report
2010-08-01
simulations. Numerical simulations were carried with a single edge notch beam using an ABAQUS user-element subroutine in conjunction with bilinear and...this effort Digital Image Correlation (DIC) has been applied to measure the coefficient of thermal expansion of the nickel-based super alloy...between 30 and 650°C, the thermal expansion coefficient of Hastelloy X was measured over this entire range and found to be in good agreement with
Steinborn, M; Fiegler, J; Kraus, V; Denne, C; Hapfelmeier, A; Wurzinger, L; Hahn, H
2011-12-01
We performed a cadaver study to evaluate the accuracy of measurements of the optic nerve and the optic nerve sheath for high resolution US (HRUS) and magnetic resonance imaging (MRI). Five Thiel-fixated cadaver specimens of the optic nerve were examined with HRUS and MRI. Measurements of the optic nerve and the ONSD were performed before and after the filling of the optic nerve sheath with saline solution. Statistical analysis included the calculation of the agreement of measurements and the evaluation of the intraobserver and interobserver variation. Overall a good correlation of measurement values between HRUS and MRI can be found (mean difference: 0.02-0.97 mm). The repeatability coefficient (RC) and concordance correlation coefficient (CCC) values were good to excellent for most acquisitions (RC 0.2-1.11 mm; CCC 0.684-0.949). The highest variation of measurement values was found for transbulbar sonography (RC 0.58-1.83 mm; CCC 0.615/0.608). If decisive anatomic structures are clearly depicted and the measuring points are set correctly, there is a good correlation between HRUS and MRI measurements of the optic nerve and the ONSD even on transbulbar sonography. As most of the standard and cut-off values that have been published for ultrasound are significantly lower than the results obtained with MRI, a reevaluation of sonographic ONSD measurement with correlation to MRI is necessary. © Georg Thieme Verlag KG Stuttgart · New York.
Isfahani, Haleh Mousavi; Aryankhesal, Aidin; Haghani, Hamid
2014-09-25
Performance of different organizations, such as hospitals is mainly influenced by their managers' performance. Nursing managers have an important role in hospital performance and their managerial skills can improve the quality of the services. Hence, the present study was conducted in order to assess the relationship between the managerial skills and the results of their performance evaluation in Teaching Hospitals of Iran University of Medical Science in 2013. The research used the cross sectional method in 2013. It was done by distributing a managerial skills assessment questionnaire, with close-ended questions in 5 choice Likert scale, among 181 managers and head nurses of hospitals of Iran university of Medical Sciences; among which 131 answered the questions. Another data collection tools was a forms to record evaluation marks from the personnel records. We used Pearson and Spearman correlation tests and SPSS for analysis and description (frequency, mean and standard deviation). Results showed that the managerial skills of the nursing mangers were fair (2.57 out of 5) and the results of the performance evaluation were in a good condition (98.44). The mangers' evaluation results and the managerial skills scores were not in a meaningful correlation (r=0.047 np=0.856). The research showed no correlation between different domains of managerial skills and the performance evaluation marks: decision making skills (r=0.074 and p=0.399), leadership (correlation coefficient 0.028 and p=0.654), motivation (correlation coefficient 0.118 and p=0.163), communication (correlation coefficient 0.116 and p=0.122), systematic thinking (correlation coefficient 0.028 and p=0.828), time management (correlation coefficient 0.077 and p=0.401) and strategic thinking (correlation coefficient 0.041 and p=0.756). Lack of any correlation and relation between managers' managerial skills and their performance evaluation results shows need to a fundamental revision at managers' performance evaluation form.
Baradaran, Aslan; Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Kachooei, Amir Reza
2016-04-01
Prospective study. We aimed to validate the Persian version of the modified Oswestry disability questionnaire (MODQ) in patients with low back pain. Modified Oswestry low back pain disability questionnaire is a well-known condition-specific outcome measure that helps quantify disability in patients with lumbar syndromes. To test the validity in a pilot study, the Persian MODQ was administered to 25 individuals with low back pain. We then enrolled 200 consecutive patients with low back pain to fill the Persian MODQ as well as the short form 36 (SF-36) questionnaire. Convergent validity of the MODQ was tested using the Spearman's correlation coefficient between the MODQ and SF-36 subscales. Intraclass correlation coefficient (ICC) and Cronbach's α coefficient were measured to test the reliability between test and retest and internal consistency of all items, respectively. ICC for individual items ranged from 0.43 to 0.80 showing good reliability and reproducibility of each individual item. Cronbach's α coefficient was 0.69 showing good internal consistency across all 10 items of the Persian MODQ. Total MODQ score showed moderate to strong correlation with the eight subscales and the two domains of the SF-36. The highest correlation was between the MODQ and the physical functioning subscale of the SF-36 (r=-0.54, p<0.001) and the physical component domain of the SF-36 (r=-0.55, p<0.001) showing that MODQ is measuring what it is supposed to measure in terms of disability and physical function. Persian version of the MODQ is a valid and reliable tool for the assessment of the disability following low back pain.
NASA Technical Reports Server (NTRS)
Taylor, Maynard F.; Kirchgessner, Thomas A.
1959-01-01
Measurements of average heat transfer and friction coefficients and local heat transfer coefficients were made with helium flowing through electrically heated smooth tubes with length-diameter ratios of 60 and 92 for the following range of conditions: Average surface temperature from 1457 to 4533 R, Reynolds numbe r from 3230 to 60,000, heat flux up to 583,200 Btu per hr per ft2 of heat transfer area, and exit Mach numbe r up to 1.0. The results indicate that, in the turbulent range of Reynolds number, good correlation of the local heat transfer coefficients is obtained when the physical properties and density of helium are evaluated at the surface temperature. The average heat transfer coefficients are best correlated on the basis that the coefficient varies with [1 + (L/D))(sup -0,7)] and that the physical properties and density are evaluated at the surface temperature. The average friction coefficients for the tests with no heat addition are in complete agreement with the Karman-Nikuradse line. The average friction coefficients for heat addition are in poor agreement with the accepted line.
Nakajima, Hisato; Yano, Kouya; Nagasawa, Kaoko; Kobayashi, Eiji; Yokota, Kuninobu
2015-01-01
On the basis of Diagnosis Procedure Combination (DPC) survey data, the factors that increase the value of function evaluation coefficient II were considered. A total of 1,505 hospitals were divided into groups I, II, and III, and the following items were considered. 1. Significant differences in function evaluation coefficient II and DPC survey data. 2. Examination of using the Mahalanobis-Taguchi (MT) method. 3. Correlation between function evaluation coefficient II and each DPC survey data item. 1. Function evaluation coefficient II was highest in group II. Group I hospitals showed the highest bed capacity, and numbers of hospitalization days, operations, chemotherapies, radiotherapies and general anesthesia procedures. 2. Using the MT method, we found that the number of ambulance conveyances was effective factor in group I hospitals, the number of general anesthesia procedures was effective factor in group II hospitals, and the bed capacity was effective factor in group III hospitals. 3. In group I hospitals, function evaluation coefficient II significantly correlated to the numbers of ambulance conveyances and chemotherapies. In group II hospitals, function evaluation coefficient II significantly correlated to bed capacity, the numbers of ambulance conveyances, hospitalization days, operations, general anesthesia procedures, and mean hospitalization days. In group III hospitals, function evaluation coefficient II significantly correlated to all items. The factors that improve the value of function evaluation coefficient II were the increases in the numbers of ambulance conveyances, chemotherapies and radiotherapies in group I hospitals, increases in the numbers of hospitalization days, operations, ambulance conveyances and general anesthesia procedures in group II hospitals, and increases in the numbers of hospitalization days, operations and ambulance conveyances. These results indicate that the profit of a hospital will increase, which will lead to medical services of good quality.
Park, Myonghwa; Kyung Kim, Sun; Jeong, Miri; Lee, Song Ja; Kim, Seon Hwa; Kim, Jinha; Lee, Dong Young
2018-04-10
The prevalence of dementia has increased rapidly with an aging Korean population. Compared to those without dementia, individuals with dementia have more and complex needs. In this study, the Korean version of the Camberwell Assessment of Need for the Elderly (CANE-K) was evaluated to determine its suitability for individuals with dementia in Korea. The CANE-K was developed following linguistic validation. The reliability of the measurement was examined with Cronbach's alpha coefficient. The factor structure and construct validity were evaluated by performing exploratory factor analysis (EFA) and confirmatory factor analyses (CFA). Pearson's correlation coefficients with related measures were used to ensure concurrent validity. Four factors extracted with EFA and CFA validated the model structure (X 2 = 367.25, p = .000, goodness of fit index = .84, adjusted goodness of fit index = .80, root mean square error of approximation = .07, and comparative fit index = .83). Items on the CANE-K loaded on the four factors in a range between .40 and .80. The output of Pearson's correlation coefficient with cognitive impairment, behavioral problems, activities of daily living and caregiver burden showed acceptable concurrent validity. The CANE-K showed a reasonable degree of reliability and validity. Therefore, it has good potential to appropriately measure the needs and unmet needs of those with dementia. Copyright © 2018. Published by Elsevier B.V.
An efficient algorithm for generating random number pairs drawn from a bivariate normal distribution
NASA Technical Reports Server (NTRS)
Campbell, C. W.
1983-01-01
An efficient algorithm for generating random number pairs from a bivariate normal distribution was developed. Any desired value of the two means, two standard deviations, and correlation coefficient can be selected. Theoretically the technique is exact and in practice its accuracy is limited only by the quality of the uniform distribution random number generator, inaccuracies in computer function evaluation, and arithmetic. A FORTRAN routine was written to check the algorithm and good accuracy was obtained. Some small errors in the correlation coefficient were observed to vary in a surprisingly regular manner. A simple model was developed which explained the qualities aspects of the errors.
Fan, Yijun; Huang, Zhaohui; Zhang, Dazhao; Chang, Jun; Jia, Yun; He, Shuihong; Wei, Bing
2017-08-01
The aim of this study was to examine the reliability and validity of the Illness Perception Questionnaire-Revised (IPQ-R) in patients with stress urinary incontinence (SUI). A total of 256 patients with SUI and 76 patients with myoma of the uterus were recruited to complete the Chinese IPQ-R. For the reliability, the key tests included Cronbach's α coefficient and intraclass correlation coefficients. For the validity, the key tests included factor analysis, Spearman's correlation coefficient, and the Student's t-test. Cronbach's α values ranged from 0.68 to 0.90 for each subscale and the intraclass correlation coefficients ranged from 0.80 to 0.94. The results of the confirmatory factor analysis showed that the seven-factor structure as proposed by the original IPQ-R fit the data poorly. Although removal of three items improved the model's fit, the goodness-of-fit statistics were still below acceptable standards. We identified an acceptable seven-factor solution from the 38 items on Illness Beliefs using an exploratory factor analysis (EFA), which accounted for 68.12% of the variance. For the concurrent validity, Consequences and Emotional Representation both had good correlations with anxiety and depression (r = 0.52-0.62) and better quality of life (r = 0.58-0.73). The inter-correlation coefficient of the seven factors ranged from 0.05 to 0.59, suggesting acceptable discriminant validity. There were significant differences on the scale scores of Disease Identity (t = 9.39, P < 0.01), Timeline-Acute/Chronic (t = 3.69, P < 0.01), Consequences (t = 4.53, P < 0.01), Illness Coherence (t = 7.73, P < 0.01), Timeline-Cyclical (t = 6.48, P < 0.01), Emotional Representation (t = 6.40, P < 0.01), and Cause (t = 4.29, P < 0.01) between the patients with SUI and with myoma of the uterus, which also indicated acceptable discriminant validity. The findings of this study supported the Chinese IPQ-R as being a reliable and valid tool for measuring illness perception among patients with SUI. © 2017 Japan Society of Obstetrics and Gynecology.
Chiou, C.T.
1985-01-01
Triolein-water partition coefficients (KtW) have been determined for 38 slightly water-soluble organic compounds, and their magnitudes have been compared with the corresponding octanol-water partition coefficients (KOW). In the absence of major solvent-solute interaction effects in the organic solvent phase, the conventional treatment (based on Raoult's law) predicts sharply lower partition coefficients for most of the solutes in triolein because of its considerably higher molecular weight, whereas the Flory-Huggins treatment predicts higher partition coefficients with triolein. The data are in much better agreement with the Flory-Huggins model. As expected from the similarity in the partition coefficients, the water solubility (which was previously found to be the major determinant of the KOW) is also the major determinant for the Ktw. When the published BCF values (bioconcentration factors) of organic compounds in fish are based on the lipid content rather than on total mass, they are approximately equal to the Ktw, which suggests at least near equilibrium for solute partitioning between water and fish lipid. The close correlation between Ktw and Kow suggests that Kow is also a good predictor for lipid-water partition coefficients and bioconcentration factors.
Xu, Feng; Liang, Xinmiao; Lin, Bingcheng; Su, Fan; Schramm, Karl-Werner; Kettrup, Antonius
2002-08-01
The capacity factors of a series of hydrophobic organic compounds (HOCs) were measured in soil leaching column chromatography (SLCC) on a soil column, and in reversed-phase liquid chromatography on a C18 column with different volumetric fractions (phi) of methanol in methanol-water mixtures. A general equation of linear solvation energy relationships, log(XYZ) XYZ0 + mV(I)/100 + spi + bbetam + aalpham, was applied to analyze capacity factors (k'), soil organic partition coefficients (Koc) and octanol-water partition coefficients (P). The analyses exhibited high accuracy. The chief solute factors that control logKoc, log P, and logk' (on soil and on C18) are the solute size (V(I)/100) and hydrogen-bond basicity (betam). Less important solute factors are the dipolarity/polarizability (pi*) and hydrogen-bond acidity (alpham). Log k' on soil and log Koc have similar signs in four fitting coefficients (m, s, b and a) and similar ratios (m:s:b:a), while log k' on C18 and logP have similar signs in coefficients (m, s, b and a) and similar ratios (m:s:b:a). Consequently, logk' values on C18 have good correlations with logP (r > 0.97), while logk' values on soil have good correlations with logKoc (r > 0.98). Two Koc estimation methods were developed, one through solute solvatochromic parameters, and the other through correlations with k' on soil. For HOCs, a linear relationship between logarithmic capacity factor and methanol composition in methanol-water mixtures could also be derived in SLCC.
The Stayhealthy bioelectrical impedance analyzer predicts body fat in children and adults.
Erceg, David N; Dieli-Conwright, Christina M; Rossuello, Amerigo E; Jensky, Nicole E; Sun, Stephanie; Schroeder, E Todd
2010-05-01
Bioelectrical impedance analysis (BIA) is a time-efficient and cost-effective method for estimating body composition. We hypothesized that there would be no significant difference between the Stayhealthy BC1 BIA and the selected reference methods when determining body composition. Thus, the purpose of the present study was to determine the validity of estimating percent body fat (%BF) using the Stayhealthy BIA with its most recently updated algorithms compared to the reference methods of dual-energy x-ray absorptiometry for adults and hydrostatic weighing for children. We measured %BF in 245 adults aged 18 to 80 years and 115 children aged 10 to 17 years. Body fat by BIA was determined using a single 50 kHz frequency handheld impedance device and proprietary software. Agreement between BIA and reference methods was assessed by Bland and Altman plots. Bland and Altman analysis for men, women, and children revealed good agreement between the reference methods and BIA. There was no significant difference by t tests between mean %BF by BIA for men, women, or children when compared to the respective reference method. Significant correlation values between BIA, and reference methods for all men, women, and children were 0.85, 0.88, and 0.79, respectively. Reliability (test-retest) was assessed by intraclass correlation coefficient and coefficient of variation. Intraclass correlation coefficient values were greater than 0.99 (P < .001) for men, women, and children with coefficient of variation values 3.3%, 1.8%, and 1.7%, respectively. The Stayhealthy BIA device demonstrated good agreement between reference methods using Bland and Altman analyses. Copyright 2010 Elsevier Inc. All rights reserved.
Born, Christoph; Amann, Benedikt L; Grunze, Heinz; Post, Robert M; Schärer, Lars
2014-05-07
Careful observation of the longitudinal course of bipolar disorders is pivotal to finding optimal treatments and improving outcome. A useful tool is the daily prospective Life-Chart Method, developed by the National Institute of Mental Health. However, it remains unclear whether the patient version is as valid as the clinician version. We compared the patient-rated version of the Lifechart (LC-self) with the Young-Mania-Rating Scale (YMRS), Inventory of Depressive Symptoms-Clinician version (IDS-C), and Clinical Global Impression-Bipolar version (CGI-BP) in 108 bipolar I and II patients who participated in the Naturalistic Follow-up Study (NFS) of the German centres of the Bipolar Collaborative Network (BCN; formerly Stanley Foundation Bipolar Network). For statistical evaluation, levels of severity of mood states on the Lifechart were transformed numerically and comparison with affective scales was performed using chi-square and t tests. For testing correlations Pearson´s coefficient was calculated. Ratings for depression of LC-self and total scores of IDS-C were found to be highly correlated (Pearson coefficient r = -.718; p < .001), whilst the correlation of ratings for mania with YMRS compared to LC-self were slightly less robust (Pearson coefficient r = .491; p = .001). These results were confirmed by good correlations between the CGI-BP IA (mania), IB (depression) and IC (overall mood state) and the LC-self ratings (Pearson coefficient r = .488, r = .721 and r = .65, respectively; all p < .001). The LC-self shows a significant correlation and good concordance with standard cross sectional affective rating scales, suggesting that the LC-self is a valid and time and money saving alternative to the clinician-rated version which should be incorporated in future clinical research in bipolar disorder. Generalizability of the results is limited by the selection of highly motivated patients in specialized bipolar centres and by the open design of the study.
Ban, Ilija; Troelsen, Anders; Kristensen, Morten Tange
2016-10-01
The Constant score (CS) has been the primary endpoint in most studies on clavicle fractures. However, the CS was not developed to assess patients with clavicle fractures. Our aim was to examine inter-rater reliability and agreement of the CS in patients with clavicle fractures. The secondary aim was to estimate the correlation between the CS and the Disabilities of the Arm, Shoulder and Hand score and the internal consistency of the 2 scores. On the basis of sample sizing, 36 patients (31 male and 5 female patients; mean age, 41.3 years) with clavicle fractures underwent standardized CS assessment at a mean of 6.8 weeks (SD, 1.0 weeks) after injury. Reliability and agreement of the CS were determined by 2 raters. The interclass correlation coefficient (ICC2,1), standard error of measurement, minimal detectable change, Cronbach α coefficient, and Pearson correlation coefficient were estimated. Inter-rater reliability of the total CS was excellent (interclass correlation coefficient, 0.94; 95% confidence interval, 0.88-0.97), with no systematic difference between the 2 raters (P = .75). The standard error of measurement (measurement error at the group level) was 4.9, whereas the minimal detectable change (smallest change needed to indicate a real change for an individual) was 13.6 CS points. The internal consistency of the 10 CS items was good, with a Cronbach α of .85, and we found a strong correlation (r = -0.92) between the CS and Disabilities of the Arm, Shoulder and Hand score. The CS was found to be reliable for assessing patients with clavicle fractures, especially at the group level. With high inter-rater reliability and agreement, in addition to good internal consistency, the standardized CS used in this study can be used for comparison of results from different settings. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Freche, John C; Schum, Eugene F
1951-01-01
Blade-to-coolant convective heat-transfer coefficients were obtained on a forced-convection water-cooled single-stage turbine over a large laminar flow range and over a portion of the transition range between laminar and turbulent flow. The convective coefficients were correlated by the general relation for forced-convection heat transfer with laminar flow. Natural-convection heat transfer was negligible for this turbine over the Grashof number range investigated. Comparison of turbine data with stationary tube data for the laminar flow of heated liquids showed good agreement. Calculated average midspan blade temperatures using theoretical gas-to-blade coefficients and blade-to-coolant coefficients from stationary-tube data resulted in close agreement with experimental data.
Miki, Emi; Yamane, Shingo; Yamaoka, Mai; Fujii, Hiroe; Ueno, Hiroka; Kawahara, Toshie; Tanaka, Keiko; Tamashiro, Hiroaki; Inoue, Eiji; Okamoto, Takatsugu; Kuriyama, Masaru
2016-09-01
The study aim was to investigate the validity and reliability of the Functional Independence Measure and Functional Assessment Measure (FIM + FAM), which is unfamiliar in Japan, by using its Japanese version (FIM + FAM-j) in patients with cerebrovascular accident (CVA). Forty-two CVA patients participated. Criterion validity was examined by correlating the full scale and subscales of FIM + FAM-j with several well-established measurements using Spearman's correlation coefficient. Reliability was evaluated by internal consistency (tested by Cronbach's alpha coefficient) and intra-rater reliability (tested by Kendall's tau correlation coefficient). Good-to-excellent criterion validity was found between the full scale and motor subscales of the FIM + FAM-j and the Barthel Index, National Institutes of Health Stroke Scale, modified Rankin Scale, and lower extremity Brunnstrom Recovery Stage. High internal consistency was observed within the full-scale FIM + FAM-j and the motor and cognitive subscales (Cronbach's alphas were 0.968, 0.954, and 0.948, respectively). Additionally, good intra-rater reliability was observed within the full scale and motor subscales, and excellent reliability for the cognitive subscales (taus were 0.83, 0.80, and 0.98, respectively). This study showed that the FIM + FAM-j demonstrated acceptable levels of validity and reliability when used for CVA as a measure of disability.
[Evaluation of the Abbott Cell-Dyn Sapphire hematology analyzer].
Park, Younhee; Song, Jaewoo; Song, Sungwook; Song, Kyung Soon; Ahn, Mee Suk; Yang, Mi-Sook; Kim, Il; Choi, Jong Rak
2007-06-01
The performance of Cell-Dyn Sapphire (Abbott Diagnostic, USA) was compared to the Bayer Advia 2120 (Bayer Diagnostics, USA), Sysmex XE-2100 (Sysmex Corporation, Japan), and reference microscopy. Three hundred samples for routine CBC and WBC differentials were randomly chosen for a comparison analysis. The Cell-Dyn Sapphire system was evaluated according to the linearity, imprecision, inter-instrument correlations, and white blood cell differential. The CBC parameters (WBC, RBC, hemoglobin and platelet) showed a significant linearity with correlation coefficients greater than 0.99 (P<0.0001). Coefficients of variation (CV) for within-run and differential count of WBC were less than 5% except for Total CV for monocytes, eosinophils, and basophils and within-run CV for low valued eosinophils. The correlation coefficients with manual count were lower in monocytes, eosinophils, and basophils than in neutrophils and lymphocytes. The correlation with other hematology anlayzers was significant exclusive of basophils. These results demonstrate that the Cell-Dyn Sapphire has a good linearity, an acceptable reproducibility, a minimal carryover, and a comparable performance with the sysmex XE-2100 and Advia 2120.
NASA Technical Reports Server (NTRS)
James, W. P. (Principal Investigator); Hill, J. M.; Bright, J. B.
1977-01-01
The author has identified the following significant results. Correlations between the satellite radiance values water color, Secchi disk visibility, turbidity, and attenuation coefficients were generally good. The residual was due to several factors including systematic errors in the remotely sensed data, errors, small time and space variations in the water quality measurements, and errors caused by experimental design. Satellite radiance values were closely correlated with the optical properties of the water.
Psychometric Properties of the Persian Version of the Simple Shoulder Test (SST) Questionnaire.
Ebrahimzadeh, Mohammad H; Vahedi, Ehsan; Baradaran, Aslan; Birjandinejad, Ali; Seyyed-Hoseinian, Seyyed-Hadi; Bagheri, Farshid; Kachooei, Amir Reza
2016-10-01
To validate the Persian version of the simple shoulder test in patients with shoulder joint problems. Following Beaton`s guideline, translation and back translation was conducted. We reached to a consensus on the Persian version of SST. To test the face validity in a pilot study, the Persian SST was administered to 20 individuals with shoulder joint conditions. We enrolled 148 consecutive patients with shoulder problem to fill the Persian SST, shoulder specific measure including Oxford shoulder score (OSS) and two general measures including DASH and SF-36. To measure the test-retest reliability, 42 patients were randomly asked to fill the Persian-SST for the second time after one week. Cronbach's alpha coefficient was used to demonstrate internal consistency over the 12 items of Persian-SST. ICC for the total questionnaire was 0.61 showing good and acceptable test-retest reliability. ICC for individual items ranged from 0.32 to 0.79. The total Cronbach's alpha was 0.84 showing good internal consistency over the 12 items of the Persian-SST. Validity testing showed strong correlation between SST and OSS and DASH. The correlation with OSS was positive while with DASH scores was negative. The correlation was also good to strong with all physical and most mental subscales of the SF-36. Correlation coefficient was higher with DASH and OSS in compare to SF-36. Persian version of SST found to be valid and reliable instrument for shoulder joint pain and function assessment in Iranian population.
Prism under cover test in alternate fixation horizontal strabismus.
Tejedor, Jaime; Gutiérrez-Carmona, Francisco José
2018-02-01
To evaluate the applicability of the prism under cover test (PUCT) to quantify manifest deviation in horizontal strabismus with alternate fixation when simultaneous prism and cover test (SPCT) is not feasible. Children aged 4-11 years, with alternate fixation horizontal strabismus and alternate prism and cover test (APCT) distance deviation (DD) up to 25 PD were eligible. In group 1 of the study, SPCT was not feasible (n = 18), whereas in group 2, it was feasible (n = 24). Refraction, PUCT, APCT, central/peripheral fusion, and stereoacuity were measured. Repeatability of PUCT, agreement between PUCT and SPCT, and Pearson correlations between variables were studied. In group 1, mean DD was 15.6 and 9.5 PD using APCT and PUCT, respectively (intraclass correlation, ICC: 0.90). Mean stereoacuity was 201.1 arc seconds. PUCT was better correlated with stereoacuity than APCT, but not significantly (p = 0.12). Coefficient of repeatability for PUCT was 3.4 PD. In group 2, mean DD was 17.6, 14.1, and 12.5 PD using APCT, PUCT, and SPCT, respectively. Mean stereoacuity was 285.9 arc seconds. Correlations APCT-PUCT (0.87), APCT-SPCT (0.82), and SPCT-PUCT (0.95) were significant. APCT did not show as good correlation with stereoacuity (0.58) as SPCT and PUCT (0.74 and 0.78, respectively). Concordance correlation coefficient between SPCT and PUCT was 0.91, and Bland Altman agreement between the two variables was also good. PUCT is a procedure with good repeatability, of interest in children to estimate manifest deviation when SPCT is not feasible, and in support of the diagnosis of monofixation syndrome.
Machado, Roberta Ismael Lacerda; Souto, Lais Medeiros; Freire, Eutilia Andrade Medeiros
2014-01-01
Systemic sclerosis (SSc) is a multisystem disease, autoimmune disorder characterized by a fibroblastic disfunction, with significant impact on quality of life (QoL), measured by instruments or questionnaires that usually were formulated in other languages and in different cultural contexts. Translate into Brazilian Portuguese, cross cultural adaptation and assess the reliability and validity of the Systemic Sclerosis Questionnaire (SySQ). Translation and adaptation: into Portuguese and cross-cultural adaptation was performed in accordance with studies on questionnaire translation methodology into other languages. Reliability: it was analyzed using three interviews with different interviewers, two on the same day (interobserver) and the third within 14 days of the first assessment (intraobserver).Validity was assessed by correlating clinical and quality of life parameters with the domain scores of Sysc. a descriptive analysis of the study sample. Reproducibility was assessed using an intraclass correlation coefficient (ICC). Internal consistency was assessed using Cronbach's alpha coefficient. To assess validity we used Spearman correlation coefficient. Five percent was the level of significance adopted for all statistical tests. In the evaluation of the questionnaires, the results were similar to the original questionnaire, the internal consistency ranging between 0.73 and 0.93 for each item. The interobserver reproducibility was very good for all domains (α = 0.786 to 0.983) and intraobserver agreement was considered very good for general symptoms domain (ICC = 0.916), good for musculoskeletal symptoms domain (ICC = 0.897) and cardiopulmonary domain (ICC = 0.842) and reasonable for gastrointestinal symptoms domain (ICC = 0.686). The Brazilian Portuguese version of SySQ proved to be reproducible and valid for our population, using a recognized methodology for translation and cultural adaptation of questionnaires, as well as to assess the reproducibility and validity.
Ogden, C A; Akobeng, A K; Abbott, J; Aggett, P; Sood, M R; Thomas, A G
2011-09-01
To validate IMPACT-III (UK), a health-related quality of life (HRQoL) instrument, in British children with inflammatory bowel disease (IBD). One hundred six children and parents were invited to participate. IMPACT-III (UK) was validated by inspection by health professionals and children to assess face and content validity, factor analysis to determine optimum domain structure, use of Cronbach alpha coefficients to test internal reliability, ANOVA to assess discriminant validity, correlation with the Child Health Questionnaire to assess concurrent validity, and use of intraclass correlation coefficients to assess test-retest reliability. The independent samples t test was used to measure differences between sexes and age groups, and between paper and computerised versions of IMPACT-III (UK). IMPACT-III (UK) had good face and content validity. The most robust factor solution was a 5-domain structure: body image, embarrassment, energy, IBD symptoms, and worries/concerns about IBD, all of which demonstrated good internal reliability (α = 0.74-0.88). Discriminant validity was demonstrated by significant (P < 0.05, P < 0.01) differences in HRQoL scores between the severe, moderate, and inactive/mild symptom severity groups for the embarrassment scale (63.7 vs 81.0 vs 81.2), IBD symptom scale (45.0 vs 64.2 vs 80.6), and the energy scale (46.4 vs 62.1 vs 77.7). Concurrent validity of IMPACT-III (UK) with comparable domains of the Child Health Questionnaire was confirmed. Test-retest reliability was confirmed with good intraclass correlation coefficients of 0.66 to 0.84. Paper and computer versions of IMPACT-III (UK) collected comparable scores, and there were no differences between the sexes and age groups. IMPACT-III (UK) appears to be a useful tool to measure HRQoL in British children with IBD.
Nüesch, Corina; Roos, Elena; Pagenstert, Geert; Mündermann, Annegret
2017-05-24
Inertial sensor systems are becoming increasingly popular for gait analysis because their use is simple and time efficient. This study aimed to compare joint kinematics measured by the inertial sensor system RehaGait® with those of an optoelectronic system (Vicon®) for treadmill walking and running. Additionally, the test re-test repeatability of kinematic waveforms and discrete parameters for the RehaGait® was investigated. Twenty healthy runners participated in this study. Inertial sensors and reflective markers (PlugIn Gait) were attached according to respective guidelines. The two systems were started manually at the same time. Twenty consecutive strides for walking and running were recorded and each software calculated sagittal plane ankle, knee and hip kinematics. Measurements were repeated after 20min. Ensemble means were analyzed calculating coefficients of multiple correlation for waveforms and root mean square errors (RMSE) for waveforms and discrete parameters. After correcting the offset between waveforms, the two systems/models showed good agreement with coefficients of multiple correlation above 0.950 for walking and running. RMSE of the waveforms were below 5° for walking and below 8° for running. RMSE for ranges of motion were between 4° and 9° for walking and running. Repeatability analysis of waveforms showed very good to excellent coefficients of multiple correlation (>0.937) and RMSE of 3° for walking and 3-7° for running. These results indicate that in healthy subjects sagittal plane joint kinematics measured with the RehaGait® are comparable to those using a Vicon® system/model and that the measured kinematics have a good repeatability, especially for walking. Copyright © 2017 Elsevier Ltd. All rights reserved.
The development and validation of a custom built device for assessing frontal knee joint laxity.
Ismail, Shiek Abdullah; Simic, Milena; Clarke, Jillian L; Lopes, Thiago Jambo Alves; Pappas, Evangelos
2017-12-01
This study reports the development and validation of a quantitative technique of assessing frontal knee joint laxity through a custom built device named KLICP. The objectives of this study were to determine: (i) the intra- and inter-rater reliability and (ii) the validity of the device when compared to real time ultrasound. Twenty-five participants had their frontal knee joint laxity assessed by the KLICP, by manual varus/valgus tests and by ultrasound. Two raters independently assessed laxity manually by three repeated measurements, repeated at least 48h later. Results were validated by comparing them to the medial and lateral joint space opening measured by the ultrasound. Intraclass correlation coefficients and standard error of measurement reliability were calculated. Pearson's correlation coefficients were calculated to determine the correlation between the KLICP and the joint space. Intra-rater reliability (intra-session) for each rater was good on both sessions (0.91-0.98), intra-rater reliability (inter-sessions) was moderate to good (0.62-0.87), and inter-rater reliability (intra-session) was good (0.75-0.80). There is low agreement for intra-rater (inter-session) and for inter-rater (intra-session) reliability. The KLICP measurement has a significant positive fair to moderate correlation to the ultrasound measurement at the left (r: 0.61, p: 0.01) and right (r: 0.48, p: 0.02) knee in the valgus direction and at the left (r: 0.51, p: 0.01) and right (r: 0.39, p: 0.05) knee in the varus direction. There is low agreement between the KLICP and the RTU. Reliability and agreement was good only when measured for intra-rater, within session. Copyright © 2017 Elsevier B.V. All rights reserved.
Development and validation of a new Prescription Quality Index
Hassan, Norul Badriah; Ismail, Hasanah Che; Naing, Lin; Conroy, Ronán M; Abdul Rahman, Abdul Rashid
2010-01-01
AIMS The aims were to develop and validate a new Prescription Quality Index (PQI) for the measurement of prescription quality in chronic diseases. METHODS The PQI were developed and validated based on three separate surveys and one pilot study. Criteria were developed based on literature search, discussions and brainstorming sessions. Validity of the criteria was examined using modified Delphi method. Pre-testing was performed on 30 patients suffering from chronic diseases. The modified version was then subjected to reviews by pharmacists and clinicians in two separate surveys. The rater-based PQI with 22 criteria was then piloted in 120 patients with chronic illnesses. Results were analysed using SPSS version 12.0.1 RESULTS Exploratory principal components analysis revealed multiple factors contributing to prescription quality. Cronbach's α for the entire 22 criteria was 0.60. The average intra-rater and inter-rater reliability showed good to moderate stability (intraclass correlation coefficient 0.76 and 0.52, respectively). The PQI was significantly and negatively correlated with age (correlation coefficient −0.34, P < 0.001), number of drugs in prescriptions (correlation coefficient −0.51, P < 0.001) and number of chronic diseases/conditions (correlation coefficient −0.35, P < 0.001). CONCLUSIONS The PQI is a promising new instrument for measuring prescription quality. It has been shown that the PQI is a valid, reliable and responsive tool to measure quality of prescription in chronic diseases. PMID:20840442
Maciel, João; Infante, Paulo; Ribeiro, Susana; Ferreira, André; Silva, Artur C; Caravana, Jorge; Carvalho, Manuel G
2014-11-01
The prevalence of obesity has increased worldwide. An assessment of the impact of obesity on health-related quality of life (HRQoL) requires specific instruments. The Moorehead-Ardelt Quality of Life Questionnaire II (MA-II) is a widely used instrument to assess HRQoL in morbidly obese patients. The objective of this study was to translate and validate a Portuguese version of the MA-II.The study included forward and backward translations of the original MA-II. The reliability of the Portuguese MA-II was estimated using the internal consistency and test-retest methods. For validation purposes, the Spearman's rank correlation coefficient was used to evaluate the correlation between the Portuguese MA-II and the Portuguese versions of two other questionnaires, the 36-item Short Form Health Survey (SF-36) and the Impact of Weight on Quality of Life-Lite (IWQOL-Lite).One hundred and fifty morbidly obese patients were randomly assigned to test the reliability and validity of the Portuguese MA-II. Good internal consistency was demonstrated by a Cronbach's alpha coefficient of 0.80, and a very good agreement in terms of test-retest reliability was recorded, with an overall intraclass correlation coefficient (ICC) of 0.88. The total sums of MA-II scores and each item of MA-II were significantly correlated with all domains of SF-36 and IWQOL-Lite. A statistically significant negative correlation was found between the MA-II total score and BMI. Moreover, age, gender and surgical status were independent predictors of MA-II total score.A reliable and valid Portuguese version of the MA-II was produced, thus enabling the routine use of MA-II in the morbidly obese Portuguese population.
The analysis of reliability and validity of the IT-MAIS, MAIS and MUSS.
Zhong, Yan; Xu, Tianqiu; Dong, Ruijuan; Lyu, Jing; Liu, Bo; Chen, Xueqing
2017-05-01
The aim of this study was to investigate the reliability and validity of the Infant-toddler Meaningful Auditory Integration Scale (IT-MAIS), Meaningful Auditory Integration Scale (MAIS), and Meaningful Use of Speech Scale (MUSS). IT-MAIS, MAIS and MUSS were divided into 3 sub dimensions. 300 children with cochlear implants (CI) were included in the investigation. To assess test-retest reliability of these questionnaires, 30 children were selected randomly to be evaluated at a two-week interval indicated that there were no significant changes between test and retest. Furthermore random test analysis by different evaluators was also administered to 30 users. Reliability test: Test-retest reliability of the three scales was proved to be satisfactory. All domains had correlation coefficients that exceeded 0.750(P < 0.01). The Cronbach's α of the three scales and their three domains were greater than 0.700. Reliability between evaluators of the three scales were considered to be satisfactory. All domains had correlation coefficients that exceeded 0.750(P < 0.01). Validity test: The evaluation of content validity by expert review showed the questionnaire had good content validity; The correlation coefficients between the overall scores of the three scales and their three domains were 0.699-0.978(P < 0.01). There were correlations among the three sub-domains but the strength of the correlations was relatively low. There was certain construct validity. IT-MAIS, MAIS, MUSS scales have good reliability and validity, and can be used to measure the outcome for children with cochlear implants hearing and speech evaluation. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluation of estimation methods for organic carbon normalized sorption coefficients
Baker, James R.; Mihelcic, James R.; Luehrs, Dean C.; Hickey, James P.
1997-01-01
A critically evaluated set of 94 soil water partition coefficients normalized to soil organic carbon content (Koc) is presented for 11 classes of organic chemicals. This data set is used to develop and evaluate Koc estimation methods using three different descriptors. The three types of descriptors used in predicting Koc were octanol/water partition coefficient (Kow), molecular connectivity (mXt) and linear solvation energy relationships (LSERs). The best results were obtained estimating Koc from Kow, though a slight improvement in the correlation coefficient was obtained by using a two-parameter regression with Kow and the third order difference term from mXt. Molecular connectivity correlations seemed to be best suited for use with specific chemical classes. The LSER provided a better fit than mXt but not as good as the correlation with Koc. The correlation to predict Koc from Kow was developed for 72 chemicals; log Koc = 0.903* log Kow + 0.094. This correlation accounts for 91% of the variability in the data for chemicals with log Kow ranging from 1.7 to 7.0. The expression to determine the 95% confidence interval on the estimated Koc is provided along with an example for two chemicals of different hydrophobicity showing the confidence interval of the retardation factor determined from the estimated Koc. The data showed that Koc is not likely to be applicable for chemicals with log Kow < 1.7. Finally, the Koc correlation developed using Kow as a descriptor was compared with three nonclass-specific correlations and two 'commonly used' class-specific correlations to determine which method(s) are most suitable.
Dang, Weimin; Cheng, Wenhong; Ma, Hong; Lin, Jin; Wu, Baoming; Ma, Ning; Wang, Rongke; Xu, Junting; Zhou, Tianhang; Yu, Xin
2015-06-01
To evaluate the reliability and validity of Professional Quality of Life Scale (ProQOL-30, 4th version, 30 items) among government staff in the Wenchuan earthquake-stricken areas A total of 1,175 members of government staff in the Wenchuan earthquake-stricken areas were selected by convenience sampling and required to complete the ProQOL and Self-Reporting Questionnair (SRQ). The reliability and validity of the scale was evaluated by correlation analysis, t-test, and confirmatory factor analysis. Item-total correlation coefficients of the three subscales were 0.590 - 0.752, 0.389 - 0.603, and 0.340 - 0.647, respectively (P<0.05), and the average coefficients were 0.672, 0.482, and 0.555 respectively (P<0.05). The Cronbach's α coefficients of the three subscales were 0.864, 0.569, and 0.742 respectively, and the split-half reliabilities were 0.829, 0.490, and 0.677, respectively. P value was 0.88 in thE chi-square test of confirmatory factor analysis model. Goodness-of-fit indices of ProQOL-30 included GFI=0.895 NFI=0.856, CFI=0.895, RMSEA=0.063, and AGFI=0.912. For the ProQOL-28 as an optimized version o ProQOL-30, the Cronbach's a coefficients for burnout and trauma/compassion fatigue increased to 0.616 and 0.757, respectively. P value was 0.91 in the chi-square test of confirmatory factor analysis model test. Goodness-of-fit indices of ProQOL-28 were GFI =0.913, AGFI =0.924, NFI =0.900, CFI =0.913, and RMSEA =0.031 CONCLUSION: ProQOL-28 has good reliability and validity among government staff in the earthquake-stricker areas in China.
Alsous, Mervat; Alhalaiqa, Fadwa; Abu Farha, Rana; Abdel Jalil, Mariam; McElnay, James; Horne, Robert
2017-01-01
Objectives to evaluate the reliability and discriminant validity of Arabic translation of the Medication Adherence Report Scale (MARS) and the Beliefs about Medication Questionnaire-specific (BMQ-specific). Methods Having developed Arabic translations of the study instruments, a cross-sectional study was carried out between March and October 2015 in two multidisciplinary governmental hospitals in Jordan. An expert panel monitored the forward and backward translation of the MARS and BMQ. Standard Arabic was used (with no specific dialect inclusion) to allow greater generalisability across Arabic speaking countries. Once the Arabic translations of the questionnaires were developed they were tested for consistency, validity and reliability on a group of children with chronic diseases and their parents. Results A total of 258 parents and 208 children were included in the study. The median age of participated children and parents was 15 years and 42 years respectively. Principle component analysis of all questionnaires indicated that all had good construct validity as they clearly measured one construct. The questionnaires were deemed reliable based on the results of Cronbach alpha coefficient. Furthermore, reliability of the questionnaires was demonstrated by test-retest intraclass correlation coefficients (ICC) which ranged from good to excellent for all scales (ICC>0.706). The Pearson correlation coefficient ranged from 0.546–0.805 for the entire sample which indicated a significant moderate to strong positive correlation between MARS and BMQ items at time 1 and 2. Reported adherence was greater than 59% using MARS-children and MARS-parents scales, and was correlated with beliefs in necessity and independent of the concerns regarding medications. Conclusion The Arabic translations of both BMQ and MARS for use in children and their parents have good internal consistency and proved to be valid and reliable tools that can be used by researchers in clinical practice to measure adherence and beliefs about medications in Arabic speaking patient populations. PMID:28192467
Alsous, Mervat; Alhalaiqa, Fadwa; Abu Farha, Rana; Abdel Jalil, Mariam; McElnay, James; Horne, Robert
2017-01-01
to evaluate the reliability and discriminant validity of Arabic translation of the Medication Adherence Report Scale (MARS) and the Beliefs about Medication Questionnaire-specific (BMQ-specific). Having developed Arabic translations of the study instruments, a cross-sectional study was carried out between March and October 2015 in two multidisciplinary governmental hospitals in Jordan. An expert panel monitored the forward and backward translation of the MARS and BMQ. Standard Arabic was used (with no specific dialect inclusion) to allow greater generalisability across Arabic speaking countries. Once the Arabic translations of the questionnaires were developed they were tested for consistency, validity and reliability on a group of children with chronic diseases and their parents. A total of 258 parents and 208 children were included in the study. The median age of participated children and parents was 15 years and 42 years respectively. Principle component analysis of all questionnaires indicated that all had good construct validity as they clearly measured one construct. The questionnaires were deemed reliable based on the results of Cronbach alpha coefficient. Furthermore, reliability of the questionnaires was demonstrated by test-retest intraclass correlation coefficients (ICC) which ranged from good to excellent for all scales (ICC>0.706). The Pearson correlation coefficient ranged from 0.546-0.805 for the entire sample which indicated a significant moderate to strong positive correlation between MARS and BMQ items at time 1 and 2. Reported adherence was greater than 59% using MARS-children and MARS-parents scales, and was correlated with beliefs in necessity and independent of the concerns regarding medications. The Arabic translations of both BMQ and MARS for use in children and their parents have good internal consistency and proved to be valid and reliable tools that can be used by researchers in clinical practice to measure adherence and beliefs about medications in Arabic speaking patient populations.
Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Kachooei, Amir Reza
2015-01-01
We aimed to validate a cross-culturally adapted version of the Persian Michigan Hand Outcomes Questionnaire (MHOQ). We followed the Beaton's guideline to translate the questionnaire to Persian. We administered the final version to 223 patients among which 79 patients returned 3 days later to respond to the Persian MHOQ for the second time. In the first visit, respondents also filled the Disabilities of the Arm Shoulder and Hand (DASH) and rated the pain based on the Visual Analogue Scale (VAS). Cronbach's alpha for the total MHOQ was 0.79 which showed good internal consistency. Intraclass correlation coefficient (ICC) for the total MHOQ was 0.84 which demonstrated good reliability between test and retest. The absolute correlation coefficient between total MHOQ and the DASH was as high as 0.74. Persian version of the MHOQ proved to be a reliable and valid instrument to be implemented among Persian population with the hand and wrist disorders.
Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen
2013-10-01
[Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86-0.99) for the elderly people and positive correlations (r = 0.58-0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability.
Data on assessment of groundwater quality with application of ArcGIS in Zanjan, Iran.
Asghari, Farzaneh Baghal; Mohammadi, Ali Akbar; Dehghani, Mohammad Hadi; Yousefi, Mahmood
2018-06-01
The aim of this study was to Monitoring of physical and chemical characteristics of ground water including Ca 2+ , Mg 2+ , EC, pH, TDS, TH, H C O 3 - , Na + , K + , Cl - , SAR, %Na and S O 4 2 - in Zanjan city, Iran. For assessing the physic-chemical parameters from 15 wells, water samples 4 times at different times were collected and examined. Data were analyzed using R and Arc GIS software. According to the calculated correlation coefficients, the highest correlation Coefficient belonged to TDS-EC while H C O 3 - and Cl - showed low and weak correlations. However, Na + , Mg 2+ , K + , Ca 2+ exhibited good positive correlations with EC and TDS. The results show that the water in the study area at the time of the study was based on the WHO standards and appropriate for drinking.
Lee, Jung Sub; Shin, Jong Ki; Son, Seung Min; An, Sung Jin; Kang, Sung Shik
2014-07-01
We aimed to evaluate the reliability and validity of the adapted Korean version of the Quality-of-Life Questionnaire of the European Foundation for Osteoporosis (QUALEFFO-26). Translation/retranslation of the English version of QUALEFFO was conducted, and all steps of the cross-cultural adaptation process were performed. The Korean version of the visual analog scale measure of pain, QUALEFFO-26 and the previously validated Short Form-36 (SF-36) were mailed to 162 consecutive patients with osteoporosis. Factor analysis and reliability assessment by kappa statistics of agreement for each item, the intraclass correlation coefficient and Cronbach's α were conducted. Construct validity was also evaluated by comparing the responses of QUALEFFO-26 with the responses of SF-36 using Pearson's correlation coefficient. Factor analysis extracted 3 factors. All items had a kappa statistics of agreement greater than 0.6. The QUALEFFO-26 showed good test/retest reliability (QUALEFFO-26: 0.8271). Internal consistency of Cronbach's α was found to be very good (QUALEFFO-26: 0.873). The Korean version of QUALEFFO-26 showed good significant correlation with SF-36 total score and with single SF-36 domains scores. The adapted Korean version of the QUALEFFO-26 was successfully translated and showed acceptable measurement properties and, as such, is considered suitable for outcome assessments in the Korean-speaking patients with osteoporosis.
Mahoney, Liam; Fernandez-Alvarez, Jose R; Rojas-Anaya, Hector; Aiton, Neil; Wertheim, David; Seddon, Paul; Rabe, Heike
2018-02-24
To explore the intra- and inter-rater agreement of superior vena cava (SVC) flow and right ventricular (RV) outflow in healthy and unwell late preterm neonates (33-37 weeks' gestational age), term neonates (≥37 weeks' gestational age), and neonates receiving total-body cooling. The intra- and inter-rater agreement (n = 25 and 41 neonates, respectively) rates for SVC flow and RV outflow were determined by echocardiography in healthy and unwell late preterm and term neonates with the use of Bland-Altman plots, the repeatability coefficient, the repeatability index, and intraclass correlation coefficients. The intra-rater repeatability index values were 41% for SVC flow and 31% for RV outflow, with intraclass correlation coefficients indicating good agreement for both measures. The inter-rater repeatability index values for SVC flow and RV outflow were 63% and 51%, respectively, with intraclass correlation coefficients indicating moderate agreement for both measures. If SVC flow or RV outflow is used in the hemodynamic treatment of neonates, sequential measurements should ideally be performed by the same clinician to reduce potential variability. © 2018 by the American Institute of Ultrasound in Medicine.
NASA Technical Reports Server (NTRS)
Yang, H. Q.; West, Jeff
2015-01-01
Current reduced-order thermal model for cryogenic propellant tanks is based on correlations built for flat plates collected in the 1950's. The use of these correlations suffers from: inaccurate geometry representation; inaccurate gravity orientation; ambiguous length scale; and lack of detailed validation. The work presented under this task uses the first-principles based Computational Fluid Dynamics (CFD) technique to compute heat transfer from tank wall to the cryogenic fluids, and extracts and correlates the equivalent heat transfer coefficient to support reduced-order thermal model. The CFD tool was first validated against available experimental data and commonly used correlations for natural convection along a vertically heated wall. Good agreements between the present prediction and experimental data have been found for flows in laminar as well turbulent regimes. The convective heat transfer between tank wall and cryogenic propellant, and that between tank wall and ullage gas were then simulated. The results showed that commonly used heat transfer correlations for either vertical or horizontal plate over predict heat transfer rate for the cryogenic tank, in some cases by as much as one order of magnitude. A characteristic length scale has been defined that can correlate all heat transfer coefficients for different fill levels into a single curve. This curve can be used for the reduced-order heat transfer model analysis.
CFD Extraction of Heat Transfer Coefficient in Cryogenic Propellant Tanks
NASA Technical Reports Server (NTRS)
Yang, H. Q.; West, Jeff
2015-01-01
Current reduced-order thermal model for cryogenic propellant tanks is based on correlations built for flat plates collected in the 1950's. The use of these correlations suffers from inaccurate geometry representation; inaccurate gravity orientation; ambiguous length scale; and lack of detailed validation. This study uses first-principles based CFD methodology to compute heat transfer from the tank wall to the cryogenic fluids and extracts and correlates the equivalent heat transfer coefficient to support reduced-order thermal model. The CFD tool was first validated against available experimental data and commonly used correlations for natural convection along a vertically heated wall. Good agreements between the present prediction and experimental data have been found for flows in laminar as well turbulent regimes. The convective heat transfer between the tank wall and cryogenic propellant, and that between the tank wall and ullage gas were then simulated. The results showed that the commonly used heat transfer correlations for either vertical or horizontal plate over-predict heat transfer rate for the cryogenic tank, in some cases by as much as one order of magnitude. A characteristic length scale has been defined that can correlate all heat transfer coefficients for different fill levels into a single curve. This curve can be used for the reduced-order heat transfer model analysis.
Yoshizawa, Shin; Matsuura, Keiko; Takagi, Ryo; Yamamoto, Mariko; Umemura, Shin-Ichiro
2016-01-01
A noninvasive technique to monitor thermal lesion formation is necessary to ensure the accuracy and safety of high-intensity focused ultrasound (HIFU) treatment. The purpose of this study is to ultrasonically detect the tissue change due to thermal coagulation in the HIFU treatment enhanced by cavitation microbubbles. An ultrasound imaging probe transmitted plane waves at a center frequency of 4.5 MHz. Ultrasonic radio-frequency (RF) echo signals during HIFU exposure at a frequency of 1.2 MHz were acquired. Cross-correlation coefficients were calculated between in-phase and quadrature (IQ) data of two B-mode images with an interval time of 50 and 500 ms for the estimation of the region of cavitation and coagulation, respectively. Pathological examination of the coagulated tissue was also performed to compare with the corresponding ultrasonically detected coagulation region. The distribution of minimum hold cross-correlation coefficient between two sets of IQ data with 50-ms intervals was compared with a pulse inversion (PI) image. The regions with low cross-correlation coefficients approximately corresponded to those with high brightness in the PI image. The regions with low cross-correlation coefficients in 500-ms intervals showed a good agreement with those with significant change in histology. The results show that the regions of coagulation and cavitation could be ultrasonically detected as those with low cross-correlation coefficients between RF frames with certain intervals. This method will contribute to improve the safety and accuracy of the HIFU treatment enhanced by cavitation microbubbles.
Balasubramanian, Vijay Anand; Douraiswami, Balaji; Subramani, Suresh
2018-06-01
Lumbar spondylolisthesis is a common cause of morbidity in middle aged individuals. Spinal fusion with instrumentation has become the gold standard for lumbar segmental instability. Studies which correlate the improvement in radiology postoperatively with functional outcome show contrasting reports. This study is aimed at finding the correlation between clinical and radiological outcomes after surgery with transforaminal lumbar interbody fusion. A retrospective study in 35 patients who underwent transforaminal lumbar interbody fusion in a period of 1 year was done. Preoperative pain (VAS Score), functional ability (ODI), radiological parameters (slip angle, slip grade, disc height, foraminal height, lumbar lordosis) were compared with postoperative recordings at the last followup. Functional improvement (Macnab's criteria) and fusion (Lee's fusion criteria) were assessed. Statistical analysis was done with student's paired t -test and Pearson's correlation coefficient. VAS score, ODI improved from 8 to 2 and 70 to 15 respectively. Slip angle improved from 23°to 5° on an average. 80% patients showed fusion and 85% showed good clinical outcome at 1 year followup. Analyzing with Pearson correlation coefficient showed no significant relation between pain scores and radiological parameters. But there was statistically significant relation between radiological fusion and the final clinical outcome. TLIF produces spinal fusion in most individuals. Strong spinal fusion is essential for good clinical outcome in spondylolisthesis patients who undergo TLIF. Reduction in slip is not necessary for all patients with listhesis.
NASA Astrophysics Data System (ADS)
Shokeen, Namita; Issa, Christopher; Mukhopadhyay, Ashis
2017-12-01
We studied the diffusion of nanoparticles (NPs) within aqueous entangled solutions of polyethylene oxide (PEO) by using two different optical techniques. Fluorescence correlation spectroscopy, a method widely used to investigate nanoparticle dynamics in polymer solution, was used to measure the long-time diffusion coefficient (D) of 25 nm radius particles within high molecular weight, Mw = 600 kg/mol PEO in water solutions. Differential dynamic microscopy (DDM) was used to determine the wave-vector dependent dynamics of NPs within the same polymer solutions. Our results showed good agreement between the two methods, including demonstration of normal diffusion and almost identical diffusion coefficients obtained by both techniques. The research extends the scope of DDM to study the dynamics and rheological properties of soft matter at a nanoscale. The measured diffusion coefficients followed a scaling theory, which can be explained by the coupling between polymer dynamics and NP motion.
Creation and Validation of the Self-esteem/Self-image Female Sexuality (SESIFS) Questionnaire
Lordello, Maria CO; Ambrogini, Carolina C; Fanganiello, Ana L; Embiruçu, Teresa R; Zaneti, Marina M; Veloso, Laise; Piccirillo, Livia B; Crude, Bianca L; Haidar, Mauro; Silva, Ivaldo
2014-01-01
INTRODUCTION Self-esteem and self-image are psychological aspects that affect sexual function. AIMS To validate a new measurement tool that correlates the concepts of self-esteem, self-image, and sexuality. METHODS A 20-question test (the self-esteem/self-image female sexuality [SESIFS] questionnaire) was created and tested on 208 women. Participants answered: Rosenberg’s self-esteem scale, the female sexual quotient (FSQ), and the SESIFS questionnaire. Pearson’s correlation coefficient was used to test concurrent validity of the SESIFS against Rosenberg’s self-esteem scale and the FSQ. Reliability was tested using the Cronbach’s alpha coefficient. RESULT The new questionnaire had a good overall reliability (Cronbach’s alpha r = 0.862, p < 0.001), but the sexual domain scored lower than expected (r = 0.65). The validity was good: overall score r = 0.38, p < 0.001, self-esteem domain r = 0.32, p < 0.001, self-image domain r = 0.31, p < 0.001, sexual domain r = 0.29, p < 0.001. CONCLUSIONS The SESIFS questionnaire has limitations in measuring the correlation among self-esteem, self-image, and sexuality domains. A new, revised version is being tested and will be presented in an upcoming publication. PMID:25574149
Creation and Validation of the Self-esteem/Self-image Female Sexuality (SESIFS) Questionnaire.
Lordello, Maria Co; Ambrogini, Carolina C; Fanganiello, Ana L; Embiruçu, Teresa R; Zaneti, Marina M; Veloso, Laise; Piccirillo, Livia B; Crude, Bianca L; Haidar, Mauro; Silva, Ivaldo
2014-01-01
Self-esteem and self-image are psychological aspects that affect sexual function. To validate a new measurement tool that correlates the concepts of self-esteem, self-image, and sexuality. A 20-question test (the self-esteem/self-image female sexuality [SESIFS] questionnaire) was created and tested on 208 women. Participants answered: Rosenberg's self-esteem scale, the female sexual quotient (FSQ), and the SESIFS questionnaire. Pearson's correlation coefficient was used to test concurrent validity of the SESIFS against Rosenberg's self-esteem scale and the FSQ. Reliability was tested using the Cronbach's alpha coefficient. The new questionnaire had a good overall reliability (Cronbach's alpha r = 0.862, p < 0.001), but the sexual domain scored lower than expected (r = 0.65). The validity was good: overall score r = 0.38, p < 0.001, self-esteem domain r = 0.32, p < 0.001, self-image domain r = 0.31, p < 0.001, sexual domain r = 0.29, p < 0.001. The SESIFS questionnaire has limitations in measuring the correlation among self-esteem, self-image, and sexuality domains. A new, revised version is being tested and will be presented in an upcoming publication.
Chaotic CDMA watermarking algorithm for digital image in FRFT domain
NASA Astrophysics Data System (ADS)
Liu, Weizhong; Yang, Wentao; Feng, Zhuoming; Zou, Xuecheng
2007-11-01
A digital image-watermarking algorithm based on fractional Fourier transform (FRFT) domain is presented by utilizing chaotic CDMA technique in this paper. As a popular and typical transmission technique, CDMA has many advantages such as privacy, anti-jamming and low power spectral density, which can provide robustness against image distortions and malicious attempts to remove or tamper with the watermark. A super-hybrid chaotic map, with good auto-correlation and cross-correlation characteristics, is adopted to produce many quasi-orthogonal codes (QOC) that can replace the periodic PN-code used in traditional CDAM system. The watermarking data is divided into a lot of segments that correspond to different chaotic QOC respectively and are modulated into the CDMA watermarking data embedded into low-frequency amplitude coefficients of FRFT domain of the cover image. During watermark detection, each chaotic QOC extracts its corresponding watermarking segment by calculating correlation coefficients between chaotic QOC and watermarked data of the detected image. The CDMA technique not only can enhance the robustness of watermark but also can compress the data of the modulated watermark. Experimental results show that the watermarking algorithm has good performances in three aspects: better imperceptibility, anti-attack robustness and security.
Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E
2014-05-01
Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.
Overby, Nina Cecilie; Johannesen, Elisabeth; Jensen, Grete; Skjaevesland, Anne-Kirsti; Haugen, Margaretha
2014-01-01
The assessment of food intake is challenging and prone to errors; it is therefore important to consider the reliability and validity of the assessment methods. The aim of this study was to analyze the reproducibility and validity of a developed food-frequency questionnaire (FFQ) for use among adolescents. In total, 58 students (aged 13-14) from four different schools in the southern part of Norway participated in the reproducibility study of filling out the FFQ 4 weeks apart. In addition, 93 students participated in the relative validity study where the FFQ was compared to 2×24-hour dietary recalls, while 92 students participated in the absolute validity study where the intakes of fatty acids and vitamin D from the FFQ were compared to fatty acids and 25-hydroxy-vitamin D3 in whole blood. The median Spearman correlation coefficient for all nutrients in the test-retest reliability study was 0.57. The median Spearman correlation for all nutrients in the relative validity study was 0.26, while the correlations coefficients were low in the absolute validity study with n-3 fatty acid coefficients ranging from 0.05 to 0.25, and absent for vitamin D (r=0.000). The test-retest reproducibility was considered good, the relative validity was considered poor to good, and the absolute validity was considered poor. However, the results are comparable to other studies among adolescents.
Sandhu, Sukhvinder Singh; Ismail, Noor Hassim; Rampal, Krishna Gopal
2015-11-01
The Perceived Stress Scale-10 (PSS-10) is widely used to assess stress perception. The aim of this study was to translate the original PSS-10 into Malay and assess the reliability and validity of the Malay version among nurses. The Malay version of the PSS-10 was distributed among 229 nurses from four government hospitals in Selangor State. Test-retest reliability and concurrent validity was conducted with 25 nurses with the Malay version of the Depression Anxiety Stress Scales (DASS) 21. Cronbach's alpha, confirmatory factor analysis (CFA), intraclass correlation coefficient and Pearson's r correlation coefficient were used to determine the psychometric properties of the Malay PSS-10. Two factor components were yielded through exploratory factor analysis with eigenvalues of 3.37 and 2.10, respectively. Both of the factors accounted for 54.6% of the variance. CFA yielded a two-factor structure with satisfactory goodness-of-fit indices [x 2 /df = 2.43; comparative fit index (CFI) = 0.92, goodness-of-fit Index (GFI) = 0.94; standardised root mean square residual (SRMR) = 0.07 and root mean square error of approximation (RMSEA) = 0.08 (90% CI = 0.07-0.09)]. The Cronbach's alpha coefficient for the total items was 0.63 (0.82 for factor 1 and 0.72 for factor 2). The intraclass correlation coefficient (ICC) was 0.81 (95% CI: 0.62-0.91) for test-retest reliability testing after seven days. The total score and the negative component of the PSS-10 correlated significantly with the stress component of the DASS-21: (r = 0.61, P < 0.001) and (r = 0.56, P < 0.004), respectively. The Malay version of the PSS-10 demonstrated a satisfactory level of validity and reliability to assess stress perception. Therefore, this questionnaire is valid in assessing stress perception among nurses in Malaysia.
Vázquez Peña, Fernando; Harzheim, Erno; Terrasa, Sergio; Berra, Silvina
2017-02-01
To validate the Brazilian short version of the PCAT for adult patients in Spanish. Analysis of secondary data from studies made to validate the extended version of the PCAT questionnaire. City of Córdoba, Argentina. Primary health care. The sample consisted of 46% of parents, whose children were enrolled in secondary education in three institutes in the city of Cordoba, and the remaining 54% were adult users of the National University of Cordoba Health Insurance. Pearson's correlation coefficient comparing the extended and short versions. Goodness-of-fit indices in confirmatory factor analysis, composite reliability, average variance extracted, and Cronbach's alpha values, in order to assess the construct validity and the reliability of the short version. The values of Pearson's correlation coefficient between this short version and the long version were high .818 (P<.001), implying a very good criterion validity. The indicators of good global adjustment to the confirmatory factor analysis were good. The value of composite reliability was good (.802), but under the variance media extracted: .3306, since 3 variables had weak factorials loads. The Cronbach's alpha was acceptable (.85). The short version of the PCAT-users developed in Brazil showed an acceptable psychometric performance in Spanish as a quick assessment tool, in a comparative study with the extended version. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
DeMoor, Stephanie; Abdel-Rehim, Shady; Olmsted, Richard; Myers, John G; Parker-Raley, Jessica
2017-07-01
Nontechnical skills (NTS), such as team communication, are well-recognized determinants of trauma team performance and good patient care. Measuring these competencies during trauma resuscitations is essential, yet few valid and reliable tools are available. We aimed to demonstrate that the Trauma Team Communication Assessment (TTCA-24) is a valid and reliable instrument that measures communication effectiveness during activations. Two tools with adequate psychometric strength (Trauma Nontechnical Skills Scale [T-NOTECHS], Team Emergency Assessment Measure [TEAM]) were identified during a systematic review of medical literature and compared with TTCA-24. Three coders used each tool to evaluate 35 stable and 35 unstable patient activations (defined according to Advanced Trauma Life Support criteria). Interrater reliability was calculated between coders using the intraclass correlation coefficient. Spearman rank correlation coefficient was used to establish concurrent validity between TTCA-24 and the other two validated tools. Coders achieved an intraclass correlation coefficient of 0.87 for stable patient activations and 0.78 for unstable activations scoring excellent on the interrater agreement guidelines. The median score for each assessment showed good team communication for all 70 videos (TEAM, 39.8 of 54; T-NOTECHS, 17.4 of 25; and TTCA-24, 87.4 of 96). A significant correlation between TTTC-24 and T-NOTECHS was revealed (p = 0.029), but no significant correlation between TTCA-24 and TEAM (p = 0.77). Team communication was rated slightly better across all assessments for stable versus unstable patient activations, but not statistically significant. TTCA-24 correlated with T-NOTECHS, an instrument measuring nontechnical skills for trauma teams, but not TEAM, a tool that assesses communication in generic emergency settings. TTCA-24 is a reliable and valid assessment that can be a useful adjunct when evaluating interpersonal and team communication during trauma activations. Diagnostic tests or criteria, level II.
Hu, Yinhuan; Zhang, Zixia; Xie, Jinzhu; Wang, Guanping
2017-02-01
The objective of this study is to describe the development of the Outpatient Experience Questionnaire (OPEQ) and to assess the validity and reliability of the scale. Literature review, patient interviews, Delphi method and Cross-sectional validation survey. Six comprehensive public hospitals in China. The survey was carried out on a sample of 600 outpatients. Acceptability of the questionnaire was assessed according to the overall response rate, item non-response rate and the average completion time. Correlation coefficients and confirmatory factor analysis were used to test construct validity. Delphi method was used to assess the content validity of the questionnaire. Cronbach's coefficient alpha and split-half reliability coefficient were used to estimate the internal reliability of the questionnaire. The overall response rate was 97.2% and the item non-response rate ranged from 0% to 0.3%. The mean completion time was 6 min. The Spearman correlations of item-total score ranged from 0.466 to 0.765. The results of confirmatory factor analysis showed that all items had factor loadings above 0.40 and the dimension intercorrelation ranged from 0.449 to 0.773, the goodness of fit of the questionnaire was reasonable. The overall authority grade of expert consultation was 0.80 and Kendall's coefficient of concordance W was 0.186. The Cronbach's coefficients alpha of six dimensions ranged from 0.708 to 0.895, the split-half reliability coefficient (Spearman-Brown coefficient) was 0.969. The OPEQ is a promising instrument covering the most important aspects which influence outpatient experiences of comprehensive public hospital in China. It has good evidence for acceptability, validity and reliability. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Sathira-Angkura, Vera; Pithankuakul, Kongkit; Sakulpipatana, Susana; Piyaskulkaew, Chaiwat; Kunakornsawat, Sombat
2012-04-20
Cross-sectional observational study to investigate psychometric properties of an adapted Thai version of the refined Scoliosis Research Society-22 (SRS-22) questionnaire. To evaluate the reliability and validity of the adapted Thai version of the refined SRS-22 questionnaire. The SRS-22 questionnaire is a valid instrument for assessing the health-related quality of life for patients with adolescent idiopathic scoliosis. Recently, the questionnaire has been translated and validated in many languages for non-English-speaking countries. Translation/retranslation of the English version of the SRS-22 was conducted, and the cross-cultural adaptation process was performed. The Thai version SRS-22 and previously validated Thai version Short-Form survey version 2.0 (SF-36V2) questionnaires were administered to 77 patients with adolescent idiopathic scoliosis who had surgical treatment. Fifty-eight patients (52 adolescent girls) had filled out the first set of questionnaires. Thirty patients of the first-time responders completed the second set of questionnaires. The mean age at the time of operation was 14.6 years and the mean age at the time of the final follow-up was 18.7 years. The mean preoperative scoliosis curve magnitude was 55.4° (range, 30°-95°) and postoperative curve magnitude was 20.1° (range, 0°-60°). Internal consistency was determined with Cronbach α coefficient. Intraclass correlation coefficient was used for test-retest reliability. Concurrent validity was evaluated by comparing SRS-22 domains with relevant domains in the SF-36V2 questionnaire, using the Pearson correlation coefficient. The mean overall Cronbach α coefficient of the adapted Thai version SRS-22 was 0.76. The 2 of corresponding domains (mental health = 0.80 and self-image = 0.83) had satisfactory internal consistency and the remaining domains (pain = 0.78; function/activity = 0.74; and satisfaction = 0.76) were good. The intraclass correlation coefficient for 5 domains was ranged from 0.79 to 0.90, which demonstrated the satisfactory test/retest reproducibility. The concurrent validity, determined by the Pearson correlation coefficient between SRS-22 and SF-36V2 domains, had a good correlation for 15 relevant comparisons (r = 0.50-0.75). The adapted Thai version of the SRS-22 questionnaire had validity and reliability, which can be used to assess the outcome of treatment among Thai-speaking patients with adolescent idiopathic scoliosis.
Comparison of culture media, simplate, and petrifilm for enumeration of yeasts and molds in food.
Taniwaki, M H; Silva, N; Banhe, A A; Iamanaka, B T
2001-10-01
The efficacy of three culture media, dichloran rose bengal chloramphenicol (DRBC), dichloran 18% glycerol agar (DG18), and potato dextrose agar (PDA) supplemented with two antibiotics, were compared with the Simplate and Petrifilm techniques for mold and yeast enumeration. The following foods were analyzed: corn meal, wheat flour, cassava flour, bread crumbs, whole meal, sliced bread, ground peanuts, mozzarella cheese, grated parmesan cheese, cheese rolls, orange juice, pineapple pulp, pineapple cake, and mushroom in conserve. Correlation coefficients of DRBC versus PDA and DG18 for recovering total mold and yeast counts from the composite of 14 foods indicated that the three media were generally equivalent. Correlation coefficients for Petrifilm versus culture media were acceptable, although not as good as between culture media. Correlation coefficients of Simplate versus DRBC, DG18, PDA, and Petrifilm for recovering total yeasts and molds from a composite of 11 foods demonstrated that there was no equivalence between the counts obtained by Simplate and other culture media and Petrifilm, with significant differences observed for the most foods analyzed.
Sharma, Mukesh C; Sharma, S
2016-12-01
A series of 2-dihydro-4-quinazolin with potent highly selective inhibitors of inducible nitric oxide synthase activities was subjected to quantitative structure activity relationships (QSAR) analysis. Statistically significant equations with high correlation coefficient (r 2 = 0.8219) were developed. The k-nearest neighbor model has showed good cross-validated correlation coefficient and external validation values of 0.7866 and 0.7133, respectively. The selected electrostatic field descriptors the presence of blue ball around R1 and R4 in the quinazolinamine moiety showed electronegative groups favorable for nitric oxide synthase activity. The QSAR models may lead to the structural requirements of inducible nitric oxide compounds and help in the design of new compounds.
Design data for radars based on 13.9 GHz Skylab scattering coefficient measurements
NASA Technical Reports Server (NTRS)
Moore, R. K. (Principal Investigator)
1974-01-01
The author has identified the following significant results. Measurements made at 13.9 GHz with the radar scatterometer on Skylab have been combined to produce median curves of the variation of scattering coefficient with angle of incidence out to 45 deg. Because of the large number of observations, and the large area averaged for each measured data point, these curves may be used as a new design base for radars. A reasonably good fit at larger angles is obtained using the theoretical expression based on an exponential height correlation function and also using Lambert's law. For angles under 10 deg, a different fit based on the exponential correlation function, and a fit based on geometric optics expressions are both reasonably valid.
Solid motor aft closure insulation erosion. [heat flux correlation for rate analysis
NASA Technical Reports Server (NTRS)
Stampfl, E.; Landsbaum, E. M.
1973-01-01
The erosion rate of aft closure insulation in a number of large solid propellant motors was empirically analyzed by correlating the average ablation rate with a number of variables that had previously been demonstrated to affect heat flux. The main correlating parameter was a heat flux based on the simplified Bartz heat transfer coefficient corrected for two-dimensional effects. A multiplying group contained terms related to port-to-throat ratio, local wall angle, grain geometry and nozzle cant angle. The resulting equation gave a good correlation and is a useful design tool.
Doubova, Svetlana V; Aguirre-Hernandez, Rebeca; Gutiérrez-de la Barrera, Marcos; Infante-Castañeda, Claudia; Pérez-Cuevas, Ricardo
2015-09-01
The purpose of this study is to validate the Mexican version of the Short-Form Supportive Care Needs survey (SCNS-SFM). A cross-sectional survey was conducted from June to December 2013 at the Oncology Hospital of the Mexican Institute of Social Security in Mexico City. The study included 825 subsequent cancer patients >20 years of age with all forms of solid cancer. Patients had prior surgical removal of histologically confirmed cancer and attended outpatient consultations. Validation of SCNS-SFM included the following: (1) content validity through a group of experts; (2) construct validity through an exploratory factor analysis based on the polychoric correlation matrix; (3) internal consistency using Cronbach's alpha; (4) convergent validity between SCNS-SFM and quality of life, anxiety, and depression scales by calculating Pearson's correlation coefficient; (5) discriminative validity through analysis of MANOVAs; and (6) test-retest reliability using intraclass correlation coefficient calculations. SCNS-SFM has 33 items with five factors accounting for 59 % of total variance. Cronbach's alpha values ranged from 0.78 to 0.90 among factors. SCNS-SFM has good convergent validity compared with quality of life and depression and anxiety scales and good discriminative validity, revealing great information, psychological support, and physical daily living needs for women, patients <60 years, and high physical daily living needs for those with <1 year since cancer diagnosis, with advanced disease stages and current chemo- or radiotherapy. Intraclass correlation coefficient between SCNS-SFM measurements was 0.9. SCNS-SFM has acceptable psychometric properties and is suitable to evaluate supportive care needs of cancer patients.
Consideration of some dilute-solution phenomena based on an expression for the Gibbs free energy
NASA Astrophysics Data System (ADS)
Jonah, D. A.
1986-07-01
Rigorous expressions based on the Lennard-Jones (6 12) potential, are presented for the Gibbs and Helmholtz free energy of a dilute mixture. These expressions give the free energy of the mixture in terms of the thermodynamic properties of the pure solvent, thereby providing a convenient means of correlating dilute mixture behavior with that of the pure solvent. Expressions for the following dilute binary solution properties are derived: Henry's constant, limiting activity coefficients with their derivatives, solid solubilities in supercritical gases, and mixed second virial coefficients. The Henry's constant expression suggests a linear temperature dependence; application to solubility data for various gases in methane and water shows a good agreement between theory and experiment. In the thermodynamic modeling of supercritical fluid extraction, we have demonstrated how to predict new solubility-pressure isotherms from a given isotherm, with encouraging results. The mixed second virial coefficient expression has also been applied to experimental data; the agreement with theory is good.
[Validity and reproducibility of Escala de Evaluación da Insatisfación Corporal para Adolescentes].
Conti, Maria Aparecida; Slater, Betzabeth; Latorre, Maria do Rosário Dias de Oliveira
2009-06-01
To validate a body dissatisfaction scale for adolescents. The study included 386 female and male adolescents aged 10 to 17 years enrolled in a private elementary and middle school in the city of São Bernardo do Campo, southeastern Brazil, in 2006. 'Escala de Evaluación da Insatisfación Corporal para Adolescentes' (body dissatisfaction scale for adolescents) was translated and culturally adapted. The Portuguese instrument was evaluated for internal consistency using Cronbach's alpha, factor analysis with Varimax rotation, discriminant validity by comparing score means according to nutritional status (low weight, normal weight, and at risk of overweight and obesity) using the Kruskal-Wallis test. Concurrent validity was assessed using Spearman's rank correlation coefficient between scores and body mass index, waist-hip ratio and waist circumference. Reproducibility was evaluated using Wilcoxon test, and intraclass correlation coefficient. The translated and back-translated scale showed good agreement with the original one. The translated scale had good internal consistency in all subgroups studied (males and females in early and intermediate adolescence) and was able to discriminate adolescents according to their nutritional status. In the concurrent analysis, all three measures were correlated, except for males in early adolescence. Its reproducibility was ascertained. The 'Escala de Evaluación da Insatisfación Corporal para Adolescentes' was successfully translated into Portuguese and adapted to the Brazilian background and showed good results. It is recommended for the evaluation of the attitudinal component of body image in adolescents.
Cross-Cultural adaptation of the General Functioning Scale of the Family
Pires, Thiago; de Assis, Simone Gonçalves; Avanci, Joviana Quintes; Pesce, Renata Pires
2016-01-01
ABSTRACT OBJECTIVE To describe the process of cross-cultural adaptation of the General Functioning Scale of the Family, a subscale of the McMaster Family Assessment Device, for the Brazilian population. METHODS The General Functioning Scale of the Family was translated into Portuguese and administered to 500 guardians of children in the second grade of elementary school in public schools of Sao Gonçalo, Rio de Janeiro, Southeastern Brazil. The types of equivalences investigated were: conceptual and of items, semantic, operational, and measurement. The study involved discussions with experts, translations and back-translations of the instrument, and psychometric assessment. Reliability and validity studies were carried out by internal consistency testing (Cronbach’s alpha), Guttman split-half correlation model, Pearson correlation coefficient, and confirmatory factor analysis. Associations between General Functioning of the Family and variables theoretically associated with the theme (father’s or mother’s drunkenness and violence between parents) were estimated by odds ratio. RESULTS Semantic equivalence was between 90.0% and 100%. Cronbach’s alpha ranged from 0.79 to 0.81, indicating good internal consistency of the instrument. Pearson correlation coefficient ranged between 0.303 and 0.549. Statistical association was found between the general functioning of the family score and the theoretically related variables, as well as good fit quality of the confirmatory analysis model. CONCLUSIONS The results indicate the feasibility of administering the instrument to the Brazilian population, as it is easy to understand and a good measurement of the construct of interest. PMID:27355464
Strain characteristics of the silica-based fiber Bragg gratings for 30-273 K
NASA Astrophysics Data System (ADS)
Li, Litong; Lv, Dajuan; Yang, Minghong; Xiong, Liangming; Luo, Jie; Tan, Lu
2018-06-01
This work studied the strain coefficient of silica-based fiber Bragg grating (FBG) at cryogenic temperatures. A dynamic temperature test with an oxygen-free copper specimen in the temperature range of 30-273 K was designed. The relationship between the strain coefficient and temperature could be characterized by three-order polynomial. A static tensile test was carried out in liquid nitrogen environment verified the effectiveness of the dynamic results. Good correlation was obtained from the two experiment results. Finally, the factors affecting the measurement error were discussed.
Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen
2013-01-01
[Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86–0.99) for the elderly people and positive correlations (r = 0.58–0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability. PMID:24259769
Regier, M; Derlin, T; Schwarz, D; Laqmani, A; Henes, F O; Groth, M; Buhk, J-H; Kooijman, H; Adam, G
2012-10-01
To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm(2)) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV(mean)) and maximum (SUV(max)) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC(mean)) and minimum ADC (ADC(min)) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearson's correlation coefficient, Bland-Altman and regression analysis were assessed. Data analysis revealed a significant inverse correlation of the ADC(min) and SUV(max) (r=-0.46; p=0.032). Testing the correlation of the ADC(min) and SUV(max) for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r=-0.47; p=0.03) and squamouscell carcinomas (r=-0.71; p=0.002), respectively. No significant correlation was found for the comparison of ADC(min) and SUV(mean) (r=-0.29; p=0.27), ADC(mean) vs. SUV(mean) (r=-0.28; p=0.31) or ADC(mean) vs. SUV(max) (r=-0.33; p=0.23). The κ-value of 0.88 indicated a good agreement between both observers. This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Heat transfer and pressure drop of condensation of hydrocarbons in tubes
NASA Astrophysics Data System (ADS)
Fries, Simon; Skusa, Severin; Luke, Andrea
2018-03-01
The heat transfer coefficient and pressure drop are investigated for propane. Two different mild steel plain tubes and saturation pressures are considered for varying mass flux and vapour quality. The pressure drop is compared to the Friedel-Correlation with two different approaches to determine the friction factor. The first is calculation as proposed by Friedel and the second is through single phase pressure drop investigations. For lower vapour qualities the experimental results are in better agreement with the approach of the calculated friction factor. For higher vapour qualities the experimental friction factor is more precise. The pressure drop increases for a decreasing tube diameter and saturation pressure. The circumferential temperature profile and heat transfer coefficients are shown for a constant vapour quality at varying mass fluxes. The subcooling is highest for the bottom of the tube and lowest for the top. The average subcooling as well as the circumferential deviation decreases for rising mass fluxes. The averaged heat transfer coefficients are compared to the model proposed by Thome and Cavallini. The experimental results are in good agreement with both correlations, however the trend is better described with the correlation from Thome. The experimental heat transfer coefficients are under predicted by Thome and over predicted by Cavallini.
The validity and reliability of an iPhone app for measuring vertical jump performance.
Balsalobre-Fernández, Carlos; Glaister, Mark; Lockey, Richard Anthony
2015-01-01
The purpose of this investigation was to analyse the concurrent validity and reliability of an iPhone app (called: My Jump) for measuring vertical jump performance. Twenty recreationally active healthy men (age: 22.1 ± 3.6 years) completed five maximal countermovement jumps, which were evaluated using a force platform (time in the air method) and a specially designed iPhone app. My jump was developed to calculate the jump height from flight time using the high-speed video recording facility on the iPhone 5 s. Jump heights of the 100 jumps measured, for both devices, were compared using the intraclass correlation coefficient, Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation and Bland-Altman plots. There was almost perfect agreement between the force platform and My Jump for the countermovement jump height (intraclass correlation coefficient = 0.997, P < 0.001; Bland-Altman bias = 1.1 ± 0.5 cm, P < 0.001). In comparison with the force platform, My Jump showed good validity for the CMJ height (r = 0.995, P < 0.001). The results of the present study showed that CMJ height can be easily, accurately and reliably evaluated using a specially developed iPhone 5 s app.
Wang, W J; Dong, J; Ren, Z P; Chen, B; He, W; Li, W D; Hao, Z W
2016-07-06
To evaluate the validity, reliability, and acceptability of the scale of knowledge, attitude, and behavior of lifestyle intervention in a diabetes high-risk population (HILKAB), and provide scientific evidence for its usage. By convenient sampling, we selected 406 individuals at high risk for diabetes for survey using the HILKAB. Pearson correlation coefficient, factor analysis, independent sampling, and t-test for high- and low-score groups were used to evaluate the content validity, construct validity, and discriminant validity of the scale. Reliability of the scale was evaluated by internal consistency, which included Cronbach's α coefficient, θ coefficient, Ω coefficient, and split-half reliability. Scale acceptability was evaluated by acceptance rate and completion time of the survey. In this study, 366 questionnaires (90.1%) was qnalified and the completion time was (8.62±2.79) minutes. Scores for knowledge, attitude, and behavior were 10.60±3.73, 26.56±3.58, 17.09±9.74, respectively. The scale had good face validity and content validity. The correlation coefficient of items and the dimension to which they belong was between 0.25 and 0.97, and the correlation coefficient of three dimensions and the entire scale was between 0.64 and 0.91, all with P<0.001. Factor analysis of the scale extracted eight common factors. The cumulative variance contribution rate was 65.23%, thereby reaching the 50% approved standard. Of 30 items there were 29 items with factor loadings ≥0.40, indicating the scale had good construct validity. For the high-score group, scores for knowledge, attitude, and behavior dimensions were 13.89±2.55, 29.56± 2.46, 28.05 ± 2.93, respectively, which were higher than those for the low-score group (7.67 ± 2.78, 23.89 ± 3.35, 6.25 ± 3.13); t-values were 55.14, 119.40, 95.29, respectively, with P<0.001. The scale consisted of three dimensions: knowledge, attitude, and behavior. The Cronbach's α coefficient was between 0.84 and 0.92, the θ coefficient was between 0.85 and 0.96, the Ω coefficient was between 0.90 and 0.94, and the split-half reliability was between 0.77 and 0.95, reaching the 0.70 standard letter. The validity, reliability, and acceptability of the HILKAB scale were satisfactory for use in a population at high risk of diabetes.
Caregiver's Anticipatory Grief in Dementia: A Pilot Study.
ERIC Educational Resources Information Center
Theut, Susan K.; And Others
1991-01-01
Administered Anticipatory Grief Scale (AGS) and Hopkins Symptom Checklist-SCL-90-R to 27 wives who were caring for their spouses suffering from dementia. Alpha coefficient for AGS was 0.84, indicating good internal consistency. AGC was positively and significantly correlated with depression, anxiety, and hostility dimensions of SCL-90-R,…
Øverby, Nina Cecilie; Johannesen, Elisabeth; Jensen, Grete; Skjaevesland, Anne-Kirsti; Haugen, Margaretha
2014-01-01
Background The assessment of food intake is challenging and prone to errors; it is therefore important to consider the reliability and validity of the assessment methods. Objective The aim of this study was to analyze the reproducibility and validity of a developed food-frequency questionnaire (FFQ) for use among adolescents. Design In total, 58 students (aged 13–14) from four different schools in the southern part of Norway participated in the reproducibility study of filling out the FFQ 4 weeks apart. In addition, 93 students participated in the relative validity study where the FFQ was compared to 2×24-hour dietary recalls, while 92 students participated in the absolute validity study where the intakes of fatty acids and vitamin D from the FFQ were compared to fatty acids and 25-hydroxy-vitamin D3 in whole blood. Results The median Spearman correlation coefficient for all nutrients in the test–retest reliability study was 0.57. The median Spearman correlation for all nutrients in the relative validity study was 0.26, while the correlations coefficients were low in the absolute validity study with n-3 fatty acid coefficients ranging from 0.05 to 0.25, and absent for vitamin D (r=0.000). Conclusion The test–retest reproducibility was considered good, the relative validity was considered poor to good, and the absolute validity was considered poor. However, the results are comparable to other studies among adolescents. PMID:25371661
Translating and validating a Training Needs Assessment tool into Greek
Markaki, Adelais; Antonakis, Nikos; Hicks, Carolyn M; Lionis, Christos
2007-01-01
Background The translation and cultural adaptation of widely accepted, psychometrically tested tools is regarded as an essential component of effective human resource management in the primary care arena. The Training Needs Assessment (TNA) is a widely used, valid instrument, designed to measure professional development needs of health care professionals, especially in primary health care. This study aims to describe the translation, adaptation and validation of the TNA questionnaire into Greek language and discuss possibilities of its use in primary care settings. Methods A modified version of the English self-administered questionnaire consisting of 30 items was used. Internationally recommended methodology, mandating forward translation, backward translation, reconciliation and pretesting steps, was followed. Tool validation included assessing item internal consistency, using the alpha coefficient of Cronbach. Reproducibility (test – retest reliability) was measured by the kappa correlation coefficient. Criterion validity was calculated for selected parts of the questionnaire by correlating respondents' research experience with relevant research item scores. An exploratory factor analysis highlighted how the items group together, using a Varimax (oblique) rotation and subsequent Cronbach's alpha assessment. Results The psychometric properties of the Greek version of the TNA questionnaire for nursing staff employed in primary care were good. Internal consistency of the instrument was very good, Cronbach's alpha was found to be 0.985 (p < 0.001) and Kappa coefficient for reproducibility was found to be 0.928 (p < 0.0001). Significant positive correlations were found between respondents' current performance levels on each of the research items and amount of research involvement, indicating good criterion validity in the areas tested. Factor analysis revealed seven factors with eigenvalues of > 1.0, KMO (Kaiser-Meyer-Olkin) measure of sampling adequacy = 0.680 and Bartlett's test of sphericity, p < 0.001. Conclusion The translated and adapted Greek version is comparable with the original English instrument in terms of validity and reliability and it is suitable to assess professional development needs of nursing staff in Greek primary care settings. PMID:17474989
[Income inequality, corruption, and life expectancy at birth in Mexico].
Idrovo, Alvaro Javier
2005-01-01
To ascertain if the effect of income inequality on life expectancy at birth in Mexico is mediated by corruption, used as a proxy of social capital. An ecological study was carried out with the 32 Mexican federative entities. Global and by sex correlations between life expectancy at birth were estimated by federative entity with the Gini coefficient, the Corruption and Good Government Index, the percentage of Catholics, and the percentage of the population speaking indigenous language. Robust linear regressions, with and without instrumental variables, were used to explore if corruption acts as intermediate variable in the studied relationship. Negative correlations with Spearman's rho near to -0.60 (p < 0.05) and greater than -0.66 (p < 0.05) between life expectancy at birth, the Gini coefficient and the population speaking indigenous language, respectively, were observed. Moreover, the Corruption and Good Government Index correlated with men's life expectancy at birth with Spearman's rho -0.3592 (p < 0.05). Regressions with instruments were more consistent than conventional ones and they show a strong negative effect (p < 0.05) of income inequality on life expectancy at birth. This effect was greater among men. The findings suggest a negative effect of income inequality on life expectancy at birth in Mexico, mediated by corruption levels and other related cultural factors.
Moghadam, Manije; Salavati, Mahyar; Sahaf, Robab; Rassouli, Maryam; Moghadam, Mojgan; Kamrani, Ahmad Ali Akbari
2018-03-01
After forward-backward translation, the LSS was administered to 334 Persian speaking, cognitively healthy elderly aged 60 years and over recruited through convenience sampling. To analyze the validity of the model's constructs and the relationships between the constructs, a confirmatory factor analysis followed by PLS analysis was performed. The Construct validity was further investigated by calculating the correlations between the LSS and the "Short Form Health Survey" (SF-36) subscales measuring similar and dissimilar constructs. The LSS was re-administered to 50 participants a month later to assess the reliability. For the eight-factor model of the life satisfaction construct, adequate goodness of fit between the hypothesized model and the model derived from the sample data was attained (positive and statistically significant beta coefficients, good R-squares and acceptable GoF). Construct validity was supported by convergent and discriminant validity, and correlations between the LSS and SF-36 subscales. Minimum Intraclass Correlation Coefficient level of 0.60 was exceeded by all subscales. Minimum level of reliability indices (Cronbach's α, composite reliability and indicator reliability) was exceeded by all subscales. The Persian-version of the Life Satisfaction Scale is a reliable and valid instrument, with psychometric properties which are consistent with the original version.
Singh, Varun Pratap; Singh, Rajkumar
2014-03-01
The aim of this study was to develop a reliable and valid Nepali version of the Psychosocial Impact of Dental Aesthetic Questionnaire (PIDAQ). Cross-sectional descriptive validation study. B.P. Koirala Institute of Health Sciences, Dharan, Nepal. A rigorous translation process including conceptual and semantic evaluation, translation, back translation and pre-testing was carried out. Two hundred and fifty-two undergraduates, including equal numbers of males and females with an age ranging from 18 to 29 years (mean age: 22·33±2·114 years), participated in this study. Reliability was assessed by Cronbach's alpha coefficient and the coefficient of correlation was used to assess correlation between items and test-retest reliability. The construct validity was tested by factorial analysis. Convergent construct validity was tested by comparison of PIDAQ scores with the aesthetic component of the index of orthodontic treatment needs (IOTN-AC) and perception of occlusion scale (POS), respectively. Discriminant construct validity was assessed by differences in score for those who demand treatment and those who did not. The response rate was 100%. One hundred and twenty-three individuals had a demand for orthodontic treatment. The Nepali PIDAQ had excellent reliability with Cronbach's alpha of 0·945, corrected item correlation between 0·525 and 0·790 and overall test-retest reliability of 0·978. The construct validity was good with formation of a new sub-domain 'Dental self-consciousness'. The scale had good correlation with IOTN-AC and POS fulfilling convergent construct validity. The discriminant construct validity was proved by significant differences in scores for subjects with demand and without demand for treatment. To conclude, Nepali version of PIDAQ has good psychometric properties and can be used effectively in this population group for further research.
NASA Astrophysics Data System (ADS)
Consalvi, J. L.; Nmira, F.
2016-03-01
The main objective of this article is to quantify the influence of the soot absorption coefficient-Planck function correlation on radiative loss and flame structure in an oxygen-enhanced propane turbulent diffusion flame. Calculations were run with and without accounting for this correlation by using a standard k-ε model and the steady laminar flamelet model (SLF) coupled to a joint Probability Density Function (PDF) of mixture fraction, enthalpy defect, scalar dissipation rate, and soot quantities. The PDF transport equation is solved by using a Stochastic Eulerian Field (SEF) method. The modeling of soot production is carried out by using a flamelet-based semi-empirical acetylene/benzene soot model. Radiative heat transfer is modeled by using a wide band correlated-k model and turbulent radiation interactions (TRI) are accounted for by using the Optically-Thin Fluctuation Approximation (OTFA). Predicted soot volume fraction, radiant wall heat flux distribution and radiant fraction are in good agreement with the available experimental data. Model results show that soot absorption coefficient and Planck function are negatively correlated in the region of intense soot emission. Neglecting this correlation is found to increase significantly the radiative loss leading to a substantial impact on flame structure in terms of mean and rms values of temperature. In addition mean and rms values of soot volume fraction are found to be less sensitive to the correlation than temperature since soot formation occurs mainly in a region where its influence is low.
Analysis of the influencing factors of PAEs volatilization from typical plastic products.
Chen, Weidong; Chi, Chenchen; Zhou, Chen; Xia, Meng; Ronda, Cees; Shen, Xueyou
2018-04-01
The primary emphasis of this research was to investigate the foundations of phthalate (PAEs) pollutant source researches and then firstly confirmed the concept of the coefficient of volatile strength, namely phthalate total content in per unit mass and unit surface area of pollutant sources. Through surveying and evaluating the coefficient of volatile strength of PAEs from typical plastic products, this research carried out reasonable classification of PAEs pollutant sources into three categories and then investigated the relationship amongst the coefficient of volatile strength as well as other environmental factors and the concentration level of total PAEs in indoor air measured in environment chambers. Research obtained phthalate concentration results under different temperature, humidity, the coefficient of volatile strength and the closed time through the chamber experiment. In addition, this study further explored the correlation and ratio of influencing factors that affect the concentration level of total PAEs in environment chambers, including environmental factors, the coefficient of volatile strengths of PAEs and contents of total PAEs in plastic products. The research created an improved database system of phthalate the coefficient of volatile strengths of each type of plastic goods, and tentatively revealed that the volatile patterns of PAEs from different typical plastic goods, finally confirmed that the coefficient of volatile strengths of PAEs is a major factor that affects the indoor air total PAEs concentration, which laid a solid foundation for further establishing the volatile equation of PAEs from plastic products. Copyright © 2017. Published by Elsevier B.V.
Psychometric properties of the Nurses Work Functioning Questionnaire (NWFQ).
Gärtner, Fania R; Nieuwenhuijsen, Karen; van Dijk, Frank J H; Sluiter, Judith K
2011-01-01
The Nurses Work Functioning Questionnaire (NWFQ) is a 50-item self-report questionnaire specifically developed for nurses and allied health professionals. Its seven subscales measure impairments in the work functioning due to common mental disorders. Aim of this study is to evaluate the psychometric properties of the NWFQ, by assessing reproducibility and construct validity. The questionnaire was administered to 314 nurses and allied health professionals with a re-test in 112 subjects. Reproducibility was assessed by the intraclass correlations coefficients (ICC) and the standard error of measurement (SEM). For construct validity, correlations were calculated with a general work functioning scale, the Endicott Work Productivity Scale (EWPS) (convergent validity) and with a physical functioning scale (divergent validity). For discriminative validity, a Mann Whitney U test was performed testing for significant differences between subjects with mental health complaints and without. All subscales showed good reliability (ICC: 0.72-0.86), except for one (ICC = 0.16). Convergent validity was good in six subscales, correlations ranged from 0.38-0.62. However, in one subscale the correlation with the EWPS was too low (0.22). Divergent validity was good in all subscales based on correlations ranged from (-0.06)-(-0.23). Discriminative validity was good in all subscales, based on significant differences between subjects with and without mental health complaints (p<0.001-p = 0.003). The NWFQ demonstrates good psychometric properties, for six of the seven subscales. Subscale "impaired decision making" needs improvement before further use.
Li, Zhenghua; Cheng, Fansheng; Xia, Zhining
2011-01-01
The chemical structures of 114 polycyclic aromatic sulfur heterocycles (PASHs) have been studied by molecular electronegativity-distance vector (MEDV). The linear relationships between gas chromatographic retention index and the MEDV have been established by a multiple linear regression (MLR) model. The results of variable selection by stepwise multiple regression (SMR) and the powerful predictive abilities of the optimization model appraised by leave-one-out cross-validation showed that the optimization model with the correlation coefficient (R) of 0.994 7 and the cross-validated correlation coefficient (Rcv) of 0.994 0 possessed the best statistical quality. Furthermore, when the 114 PASHs compounds were divided into calibration and test sets in the ratio of 2:1, the statistical analysis showed our models possesses almost equal statistical quality, the very similar regression coefficients and the good robustness. The quantitative structure-retention relationship (QSRR) model established may provide a convenient and powerful method for predicting the gas chromatographic retention of PASHs.
Sinzobahamvya, N; Kopp, T; Photiadis, J; Arenz, C; Schindler, E; Haun, C; Hraska, V; Asfour, B
2010-09-01
Hospital costs are expected to correlate with clinical complexity. Do costs for congenital heart surgery correlate with Aristotle complexity scores? 442 inpatient stays in 2008 were evaluated. Aristotle scores and levels were determined. Costs were estimated according to the German Institute for Hospital Reimbursement system. Pearson and Spearman R correlation coefficients and corresponding goodness-of-fit regression coefficients R2 were calculated. Mean basic and comprehensive Aristotle scores were 7.60 +/- 2.74 and 9.23 +/- 2.94 points, respectively. Mean expenses per hospital stay amounted to 29,369 +/- 30,823 Euros. Aristotle basic and comprehensive scores and levels were positively correlated with hospital costs. With a Spearman R of 1 and related R2 of 0.9436, scores of the 6 Aristotle comprehensive levels correlated best. Mean hospital reimbursement was 26,412 +/- 17,962 Euros. Compensation was higher than expenses for patients in comprehensive levels 1 to 3, but much lower for those in levels 4 to 6. Aristotle comprehensive complexity scores were highly correlated with hospital costs. The Aristotle score could be used as a scale to establish the correct reimbursement after congenital heart surgery. Georg Thieme Verlag KG Stuttgart, New York.
Chao, Keh-Ping; Wang, Ping; Wang, Ya-Ting
2007-04-02
The chemical resistance of eight organic solvents in high density polyethylene (HDPE) geomembrane has been investigated using the ASTM F739 permeation method and the immersion test at different temperatures. The diffusion of the experimental organic solvents in HDPE geomembrane was non-Fickian kinetic, and the solubility coefficients can be consistent with the solubility parameter theory. The diffusion coefficients and solubility coefficients determined by the ASTM F739 method were significantly correlated to the immersion tests (p<0.001). The steady state permeation rates also showed a good agreement between ASTM F739 and immersion experiments (r(2)=0.973, p<0.001). Using a one-dimensional diffusion equation based on Fick's second law, the diffusion and solubility coefficients obtained by immersion test resulted in over estimates of the ASTM F739 permeation results. The modeling results indicated that the diffusion and solubility coefficients should be obtained using ASTM F739 method which closely simulates the practical application of HDPE as barriers in the field.
Modal sound transmission loss of a single leaf panel: Effects of inter-modal coupling.
Wang, Chong
2015-06-01
Sound transmission through a single leaf panel has mostly been discussed and explained by using the approaching wave concept, from which the well-known mass law can be derived. In this paper, the modal behavior in sound transmission coefficients is explored, and it is shown that the mutual modal radiation impedances in modal sound transmission coefficients may not be ignored even for a panel immersed in a light fluid. By introducing the equivalent modal impedance which incorporates the inter-modal coupling effect, an analytical expression for the modal sound transmission coefficient is derived, and the overall sound transmission coefficient is simply a modal superposition of modal sound transmission coefficients. A good correlation is obtained between analytical calculation and boundary element method. In addition, it is found that inter-modal coupling has noticeable effects in modal sound transmission coefficients in the subsonic region but may be ignored as modes become supersonic. It is also shown that the well-known mass law performance is attributed to all the supersonic modes.
Lim, Renly; Liong, Men Long; Khan, Nurzalina Abdul Karim; Yuen, Kah Hay
2017-02-17
There is currently no published information on the validity and reliability of the Golombok Rust Inventory of Sexual Satisfaction in the Asian population, specifically in patients with stress urinary incontinence, which limits its use in this region. Our study aimed to evaluate the psychometric properties of this questionnaire in the Malaysian population. Ten couples were recruited for the pilot testing. The agreement between the English and Chinese or Malay versions were tested using the intraclass correlation coefficients, with results of more than 0.80 for all subscales and overall scores indicating good agreement. Sixty-six couples were included in the subsequent phase. The following data are presented in the order of English, Chinese, and Malay. Cronbach's alphas for the male total score were 0.82, 0.88, and 0.95. For the female total score, Cronbach's alphas were 0.76, 0.78, and 0.88. Intraclass correlation coefficients for the male total score were 0.93, 0.94, and 0.99, while intraclass correlation coefficients for the female total score were 0.89, 0.86, and 0.88. In conclusion, the English, Chinese, and Malay versions each proved to be valid and reliable in our Malaysian population.
Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A
2015-05-01
Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Zhang, Xinmiao; Liao, Xiaoling; Wang, Chunjuan; Liu, Liping; Wang, Chunxue; Zhao, Xingquan; Pan, Yuesong; Wang, Yilong; Wang, Yongjun
2015-08-01
The DRAGON score predicts functional outcome of ischemic stroke patients treated with intravenous thrombolysis. Our aim was to evaluate its utility in a Chinese stroke population. Patients with acute ischemic stroke treated with intravenous thrombolysis were prospectively registered in the Thrombolysis Implementation and Monitor of acute ischemic Stroke in China. We excluded patients with basilar artery occlusion and missing data, leaving 970 eligible patients. We calculated the DRAGON score, and the clinical outcome was measured by the modified Rankin Scale at 3 months. Model discrimination was quantified by calculating the C statistic. Calibration was assessed using Pearson correlation coefficient. The C statistic was .73 (.70-.76) for good outcome and .75 (.70-.79) for miserable outcome. Proportions of patients with good outcome were 94%, 83%, 70%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 3%, 9%, and 50% for 0 to 1, 2, 3, and 8 to 10 points, respectively. There was high correlation between predicted and observed probability of 3-month favorable and miserable outcome in the external validation cohort (Pearson correlation coefficient, .98 and .98, respectively, both P < .0001). The DRAGON score showed good performance to predict functional outcome after tissue-type plasminogen activator treatment in the Chinese population. This study demonstrated the accuracy and usability of the DRAGON score in the Chinese population in daily practice. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Gwynne, Craig R; Curran, Sarah A
2014-12-01
Clinical assessment of lower limb kinematics during dynamic tasks may identify individuals who demonstrate abnormal movement patterns that may lead to etiology of exacerbation of knee conditions such as patellofemoral joint (PFJt) pain. The purpose of this study was to determine the reliability, validity and associated measurement error of a clinically appropriate two-dimensional (2-D) procedure of quantifying frontal plane knee alignment during single limb squats. Nine female and nine male recreationally active subjects with no history of PFJt pain had frontal plane limb alignment assessed using three-dimensional (3-D) motion analysis and digital video cameras (2-D analysis) while performing single limb squats. The association between 2-D and 3-D measures was quantified using Pearson's product correlation coefficients. Intraclass correlation coefficients (ICCs) were determined for within- and between-session reliability of 2-D data and standard error of measurement (SEM) was used to establish measurement error. Frontal plane limb alignment assessed with 2-D analysis demonstrated good correlation compared with 3-D methods (r = 0.64 to 0.78, p < 0.001). Within-session (0.86) and between-session ICCs (0.74) demonstrated good reliability for 2-D measures and SEM scores ranged from 2° to 4°. 2-D measures have good consistency and may provide a valid measure of lower limb alignment when compared to existing 3-D methods. Assessment of lower limb kinematics using 2-D methods may be an accurate and clinically useful alternative to 3-D motion analysis when identifying individuals who demonstrate abnormal movement patterns associated with PFJt pain. 2b.
Osinga, Rik; Babst, Doris; Bodmer, Elvira S; Link, Bjoern C; Fritsche, Elmar; Hug, Urs
2017-12-01
This work assessed both subjective and objective postoperative parameters after breast reduction surgery and compared between patients and plastic surgeons. After an average postoperative observation period of 6.7 ± 2.7 (2 - 13) years, 159 out of 259 patients (61 %) were examined. The mean age at the time of surgery was 37 ± 14 (15 - 74) years. The postoperative anatomy of the breast and other anthropometric parameters were measured in cm with the patient in an upright position. The visual analogue scale (VAS) values for symmetry, size, shape, type of scar and overall satisfaction both from the patient's and from four plastic surgeons' perspectives were assessed and compared. Patients rated the postoperative result significantly better than surgeons. Good subjective ratings by patients for shape, symmetry and sensitivity correlated with high scores for overall assessment. Shape had the strongest influence on overall satisfaction (regression coefficient 0.357; p < 0.001), followed by symmetry (regression coefficient 0.239; p < 0.001) and sensitivity (regression coefficient 0.109; p = 0.040) of the breast. The better the subjective rating for symmetry by the patient, the smaller the measured difference of the jugulum-mamillary distance between left and right (regression coefficient -0.773; p = 0.002) and the smaller the difference in height of the lowest part of the breast between left and right (regression coefficient -0.465; p = 0.035). There was no significant correlation between age, weight, height, BMI, resected weight of the breast, postoperative breast size or type of scar with overall satisfaction. After breast reduction surgery, long-term outcome is rated significantly better by patients than by plastic surgeons. Good subjective ratings by patients for shape, symmetry and sensitivity correlated with high scores for overall assessment. Shape had the strongest influence on overall satisfaction, followed by symmetry and sensitivity of the breast. Postoperative size of the breast, resection weight, type of scar, age or BMI was not of significant influence. Symmetry was the only assessed subjective parameter of this study that could be objectified by postoperative measurements. Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Hurdebise, Quentin; Heinesch, Bernard; De Ligne, Anne; Vincke, Caroline; Aubinet, Marc
2017-04-01
Long-term data series of carbon dioxide and other gas exchanges between terrestrial ecosystems and atmosphere become more and more numerous. Long-term analyses of such exchanges require a good understanding of measurement conditions during the investigated period. Independently of climate drivers, measurements may indeed be influenced by measurement conditions themselves subjected to long-term variability due to vegetation growth or set-up changes. The present research refers to the Vielsalm Terrestrial Observatory (VTO) an ICOS candidate site located in a mixed forest (beech, silver fir, Douglas fir, Norway spruce) in the Belgian Ardenne. Fluxes of momentum, carbon dioxide and sensible heat have been continuously measured there by eddy covariance for more than 20 years. During this period, changes in canopy height and measurement height occurred. The correlation coefficients (for momemtum, sensible heat and CO2) and the normalized standard deviations measured for the past 20 years at the Vielsalm Terrestrial Observatory (VTO) were analysed in order to define how the fluxes, independently of climate conditions, were affected by the surrounding environment evolution, including tree growth, forest thinning and tower height change. A relationship between canopy aerodynamic distance and the momentum correlation coefficient was found which is characteristic of the roughness sublayer, and suggests that momentum transport processes were affected by z-d. In contrast, no relationship was found for sensible heat and CO2 correlation coefficients, suggesting that the z-d variability observed did not affect their turbulent transport. There were strong differences in these coefficients, however, between two wind sectors, characterized by contrasted stands (height differences, homogeneity) and different hypotheses were raised to explain it. This study highlighted the importance of taking the surrounding environment variability into account in order to ensure the spatio-temporal consistency of datasets.
Trouli, Marianna N; Vernon, Howard T; Kakavelakis, Kyriakos N; Antonopoulou, Maria D; Paganas, Aristofanis N; Lionis, Christos D
2008-07-22
Neck pain is a highly prevalent condition resulting in major disability. Standard scales for measuring disability in patients with neck pain have a pivotal role in research and clinical settings. The Neck Disability Index (NDI) is a valid and reliable tool, designed to measure disability in activities of daily living due to neck pain. The purpose of our study was the translation and validation of the NDI in a Greek primary care population with neck complaints. The original version of the questionnaire was used. Based on international standards, the translation strategy comprised forward translations, reconciliation, backward translation and pre-testing steps. The validation procedure concerned the exploration of internal consistency (Cronbach alpha), test-retest reliability (Intraclass Correlation Coefficient, Bland and Altman method), construct validity (exploratory factor analysis) and responsiveness (Spearman correlation coefficient, Standard Error of Measurement and Minimal Detectable Change) of the questionnaire. Data quality was also assessed through completeness of data and floor/ceiling effects. The translation procedure resulted in the Greek modified version of the NDI. The latter was culturally adapted through the pre-testing phase. The validation procedure raised a large amount of missing data due to low applicability, which were assessed with two methods. Floor or ceiling effects were not observed. Cronbach alpha was calculated as 0.85, which was interpreted as good internal consistency. Intraclass correlation coefficient was found to be 0.93 (95% CI 0.84-0.97), which was considered as very good test-retest reliability. Factor analysis yielded one factor with Eigenvalue 4.48 explaining 44.77% of variance. The Spearman correlation coefficient (0.3; P = 0.02) revealed some relation between the change score in the NDI and Global Rating of Change (GROC). The SEM and MDC were calculated as 0.64 and 1.78 respectively. The Greek version of the NDI measures disability in patients with neck pain in a reliable, valid and responsive manner. It is considered a useful tool for research and clinical settings in Greek Primary Health Care.
Trouli, Marianna N; Vernon, Howard T; Kakavelakis, Kyriakos N; Antonopoulou, Maria D; Paganas, Aristofanis N; Lionis, Christos D
2008-01-01
Background Neck pain is a highly prevalent condition resulting in major disability. Standard scales for measuring disability in patients with neck pain have a pivotal role in research and clinical settings. The Neck Disability Index (NDI) is a valid and reliable tool, designed to measure disability in activities of daily living due to neck pain. The purpose of our study was the translation and validation of the NDI in a Greek primary care population with neck complaints. Methods The original version of the questionnaire was used. Based on international standards, the translation strategy comprised forward translations, reconciliation, backward translation and pre-testing steps. The validation procedure concerned the exploration of internal consistency (Cronbach alpha), test-retest reliability (Intraclass Correlation Coefficient, Bland and Altman method), construct validity (exploratory factor analysis) and responsiveness (Spearman correlation coefficient, Standard Error of Measurement and Minimal Detectable Change) of the questionnaire. Data quality was also assessed through completeness of data and floor/ceiling effects. Results The translation procedure resulted in the Greek modified version of the NDI. The latter was culturally adapted through the pre-testing phase. The validation procedure raised a large amount of missing data due to low applicability, which were assessed with two methods. Floor or ceiling effects were not observed. Cronbach alpha was calculated as 0.85, which was interpreted as good internal consistency. Intraclass correlation coefficient was found to be 0.93 (95% CI 0.84–0.97), which was considered as very good test-retest reliability. Factor analysis yielded one factor with Eigenvalue 4.48 explaining 44.77% of variance. The Spearman correlation coefficient (0.3; P = 0.02) revealed some relation between the change score in the NDI and Global Rating of Change (GROC). The SEM and MDC were calculated as 0.64 and 1.78 respectively. Conclusion The Greek version of the NDI measures disability in patients with neck pain in a reliable, valid and responsive manner. It is considered a useful tool for research and clinical settings in Greek Primary Health Care. PMID:18647393
Huang, L; Fantke, P; Ernstoff, A; Jolliet, O
2017-11-01
Indoor releases of organic chemicals encapsulated in solid materials are major contributors to human exposures and are directly related to the internal diffusion coefficient in solid materials. Existing correlations to estimate the diffusion coefficient are only valid for a limited number of chemical-material combinations. This paper develops and evaluates a quantitative property-property relationship (QPPR) to predict diffusion coefficients for a wide range of organic chemicals and materials. We first compiled a training dataset of 1103 measured diffusion coefficients for 158 chemicals in 32 consolidated material types. Following a detailed analysis of the temperature influence, we developed a multiple linear regression model to predict diffusion coefficients as a function of chemical molecular weight (MW), temperature, and material type (adjusted R 2 of .93). The internal validations showed the model to be robust, stable and not a result of chance correlation. The external validation against two separate prediction datasets demonstrated the model has good predicting ability within its applicability domain (Rext2>.8), namely MW between 30 and 1178 g/mol and temperature between 4 and 180°C. By covering a much wider range of organic chemicals and materials, this QPPR facilitates high-throughput estimates of human exposures for chemicals encapsulated in solid materials. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Remotely sensing wheat maturation with radar
NASA Technical Reports Server (NTRS)
Bush, T. F.; Ulaby, F. T.
1975-01-01
The scattering properties of wheat were studied in the 8-18 GHz band as a function of frequency, polarization, incidence angle, and crop maturity. Supporting ground truth was collected at the time of measurement. The data indicate that the radar backscattering coefficient is sensitive to both radar system parameters and crop characteristics particularly at incidence angles near nadir. Linear regression analyses of the radar backscattering coefficient on both time and plant moisture content result in rather good correlation. Furthermore, by calculating the average time rate of change of the radar backscattering coefficient it is found that it undergoes rapid variations shortly before and after the wheat is harvested. Both of these analyses suggest methods for estimating wheat maturity and for monitoring the progress of harvest.
Ye, Weitao; Li, Jinglei; Guo, Chengwei; Chen, Shuting; Liu, Yu-Bao; Liu, Zaiyi; Wu, Haijun; Wang, Guangyi; Liang, Changhong
2016-06-01
To investigate whether intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) can be used to quantitatively analyze the cellular injury and microcirculation alterations in hepatic ischemia-reperfusion injury (HIRI). Thirty-two New Zealand white rabbits were randomly and equally assigned to the sham group, 1-hour, 4-hour, and 12-hour groups according to the reperfusion time after 1 hour of ischemia using a 70% liver ischemia-reperfusion injury model. All the animals underwent IVIM-DWI with 12 b values at 1.5T. The imaging parameters (IVIM parameters and apparent diffusion coefficient [ADC]) among different groups were compared. The correlations between imaging parameters and histological scores, and the ratio of serum aspartate aminotransferase to serum alanine aminotransferase (serum AST/ALT) were analyzed. During the first hour of HIRI, true diffusion coefficient (D) and ADC significantly decreased (P < 0.05), while there was no significant decrease in perfusion fraction (f) (P = 0.708). There was fair to good correlation between histological scores and f (rs = -0.493 with the sham cases excluded, and -0.682 with all cases, both P < 0.05) and ADC (rs = -0.479 with the sham cases excluded, and -0.766 with all cases, both P < 0.05). There was no correlation between imaging parameters and serum AST/ALT with the sham cases excluded (P = 0.673 for f, 0.568 for D, 0.403 for ADC), and good correlation between D, ADC, and serum AST/ALT (r = 0.747 and 0.748, both P < 0.001) with all cases. IVIM-DWI can quantitatively characterize an animal model of HIRI, with D and ADC sensitive in early detection of cellular injury, as well as fair to good correlation between f, ADC, and microcirculation alteration. J. Magn. Reson. Imaging 2016;43:1327-1336. © 2015 Wiley Periodicals, Inc.
Reproducibility of abdominal fat assessment by ultrasound and computed tomography
Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge
2017-01-01
Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024
Reproducibility of abdominal fat assessment by ultrasound and computed tomography.
Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge
2017-01-01
To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.
Prediction of soil organic carbon partition coefficients by soil column liquid chromatography.
Guo, Rongbo; Liang, Xinmiao; Chen, Jiping; Wu, Wenzhong; Zhang, Qing; Martens, Dieter; Kettrup, Antonius
2004-04-30
To avoid the limitation of the widely used prediction methods of soil organic carbon partition coefficients (KOC) from hydrophobic parameters, e.g., the n-octanol/water partition coefficients (KOW) and the reversed phase high performance liquid chromatographic (RP-HPLC) retention factors, the soil column liquid chromatographic (SCLC) method was developed for KOC prediction. The real soils were used as the packing materials of RP-HPLC columns, and the correlations between the retention factors of organic compounds on soil columns (ksoil) and KOC measured by batch equilibrium method were studied. Good correlations were achieved between ksoil and KOC for three types of soils with different properties. All the square of the correlation coefficients (R2) of the linear regression between log ksoil and log KOC were higher than 0.89 with standard deviations of less than 0.21. In addition, the prediction of KOC from KOW and the RP-HPLC retention factors on cyanopropyl (CN) stationary phase (kCN) was comparatively evaluated for the three types of soils. The results show that the prediction of KOC from kCN and KOW is only applicable to some specific types of soils. The results obtained in the present study proved that the SCLC method is appropriate for the KOC prediction for different types of soils, however the applicability of using hydrophobic parameters to predict KOC largely depends on the properties of soil concerned.
Peyrard, N; Dieckmann, U; Franc, A
2008-05-01
Models of infectious diseases are characterized by a phase transition between extinction and persistence. A challenge in contemporary epidemiology is to understand how the geometry of a host's interaction network influences disease dynamics close to the critical point of such a transition. Here we address this challenge with the help of moment closures. Traditional moment closures, however, do not provide satisfactory predictions close to such critical points. We therefore introduce a new method for incorporating longer-range correlations into existing closures. Our method is technically simple, remains computationally tractable and significantly improves the approximation's performance. Our extended closures thus provide an innovative tool for quantifying the influence of interaction networks on spatially or socially structured disease dynamics. In particular, we examine the effects of a network's clustering coefficient, as well as of new geometrical measures, such as a network's square clustering coefficients. We compare the relative performance of different closures from the literature, with or without our long-range extension. In this way, we demonstrate that the normalized version of the Bethe approximation-extended to incorporate long-range correlations according to our method-is an especially good candidate for studying influences of network structure. Our numerical results highlight the importance of the clustering coefficient and the square clustering coefficient for predicting disease dynamics at low and intermediate values of transmission rate, and demonstrate the significance of path redundancy for disease persistence.
Jin, Brian; Wang, Dingxin; Lewandowski, Robert J.; Ryu, Robert K.; Sato, Kent T.; Larson, Andrew C.; Salem, Riad; Omary, Reed A.
2011-01-01
PURPOSE We aimed to test the hypothesis that subjective angiographic endpoints during transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) exhibit consistency and correlate with objective intraprocedural reductions in tumor perfusion as determined by quantitative four dimensional (4D) transcatheter intraarterial perfusion (TRIP) magnetic resonance (MR) imaging. MATERIALS AND METHODS This prospective study was approved by the institutional review board. Eighteen consecutive patients underwent TACE in a combined MR/interventional radiology (MR-IR) suite. Three board-certified interventional radiologists independently graded the angiographic endpoint of each procedure based on a previously described subjective angiographic chemoembolization endpoint (SACE) scale. A consensus SACE rating was established for each patient. Patients underwent quantitative 4D TRIP-MR imaging immediately before and after TACE, from which mean whole tumor perfusion (Fρ) was calculated. Consistency of SACE ratings between observers was evaluated using the intraclass correlation coefficient (ICC). The relationship between SACE ratings and intraprocedural TRIP-MR imaging perfusion changes was evaluated using Spearman’s rank correlation coefficient. RESULTS The SACE rating scale demonstrated very good consistency among all observers (ICC = 0.80). The consensus SACE rating was significantly correlated with both absolute (r = 0.54, P = 0.022) and percent (r = 0.85, P < 0.001) intraprocedural perfusion reduction. CONCLUSION The SACE rating scale demonstrates very good consistency between raters, and significantly correlates with objectively measured intraprocedural perfusion reductions during TACE. These results support the use of the SACE scale as a standardized alternative method to quantitative 4D TRIP-MR imaging to classify patients based on embolic endpoints of TACE. PMID:22021520
van Meeteren, Jetty; Nieuwenhuijsen, Channah; de Grund, Arthur; Stam, Henk J; Roebroeck, Marij E
2010-01-01
The study aimed to establish whether the manual ability classification system (MACS), a valid classification system for manual ability in children with cerebral palsy (CP), is applicable in young adults with CP and normal intelligence. The participants (n = 83) were young adults with CP and normal intelligence and had a mean age of 19.9 years. In this study, inter observer reliability of the MACS was determined. We investigated relationships between the MACS level and patient characteristics (such as the gross motor function classification system (GMFCS) level, limb distribution of the spastic paresis and educational level) and with functional activities of the upper extremity (assessed with the Melbourne assessment, the Abilhand questionnaire and the domain self-care of the functional independence measure (FIM)). Furthermore, with a linear regression analysis it was determined whether the MACS is a significant determinant of activity limitations and participation restrictions. The reliability was good (intraclass correlation coefficient 0.83). The Spearman correlation coefficients with GMFCS level, limb distribution of the spastic paresis and educational level were 0.53, 0.46, and 0.26, respectively. MACS level correlated moderately with outcome measures of functional activities (correlations ranging from -0.38 to -0.55). MACS level is, in addition to the GMFCS level, an important determinant for limitations in activities and restrictions in participation. We conclude that the MACS is a feasible method to classify manual ability in young adults with CP and normal intelligence with a good manual ability.
Self-esteem recognition based on gait pattern using Kinect.
Sun, Bingli; Zhang, Zhan; Liu, Xingyun; Hu, Bin; Zhu, Tingshao
2017-10-01
Self-esteem is an important aspect of individual's mental health. When subjects are not able to complete self-report questionnaire, behavioral assessment will be a good supplement. In this paper, we propose to use gait data collected by Kinect as an indicator to recognize self-esteem. 178 graduate students without disabilities participate in our study. Firstly, all participants complete the 10-item Rosenberg Self-Esteem Scale (RSS) to acquire self-esteem score. After completing the RRS, each participant walks for two minutes naturally on a rectangular red carpet, and the gait data are recorded using Kinect sensor. After data preprocessing, we extract a few behavioral features to train predicting model by machine learning. Based on these features, we build predicting models to recognize self-esteem. For self-esteem prediction, the best correlation coefficient between predicted score and self-report score is 0.45 (p<0.001). We divide the participants according to gender, and for males, the correlation coefficient is 0.43 (p<0.001), for females, it is 0.59 (p<0.001). Using gait data captured by Kinect sensor, we find that the gait pattern could be used to recognize self-esteem with a fairly good criterion validity. The gait predicting model can be taken as a good supplementary method to measure self-esteem. Copyright © 2017 Elsevier B.V. All rights reserved.
Analytical determination of propeller performance degradation due to ice accretion
NASA Technical Reports Server (NTRS)
Miller, T. L.
1986-01-01
A computer code has been developed which is capable of computing propeller performance for clean, glaze, or rime iced propeller configurations, thereby providing a mechanism for determining the degree of performance degradation which results from a given icing encounter. The inviscid, incompressible flow field at each specified propeller radial location is first computed using the Theodorsen transformation method of conformal mapping. A droplet trajectory computation then calculates droplet impingement points and airfoil collection efficiency for each radial location, at which point several user-selectable empirical correlations are available for determining the aerodynamic penalities which arise due to the ice accretion. Propeller performance is finally computed using strip analysis for either the clean or iced propeller. In the iced mode, the differential thrust and torque coefficient equations are modified by the drag and lift coefficient increments due to ice to obtain the appropriate iced values. Comparison with available experimental propeller icing data shows good agreement in several cases. The code's capability to properly predict iced thrust coefficient, power coefficient, and propeller efficiency is shown to be dependent on the choice of empirical correlation employed as well as proper specification of radial icing extent.
Yi, Honglei; Wei, Xianzhao; Zhang, Wei; Chen, Ziqiang; Wang, Xinhui; Ji, Xinran; Zhu, Xiaodong; Wang, Fei; Xu, Ximing; Li, Zhikun; Fan, Jianping; Wang, Chuanfeng; Chen, Kai; Zhang, Guoyou; Zhao, Yinchuan; Li, Ming
2014-05-01
This was a prospective clinical validation study. To evaluate the reliability and validity of the adapted simplified Chinese version of Swiss Spinal Stenosis (SC-SSS) Questionnaire. The SSS Questionnaire is a reliable and valid instrument to assess the perception of function and pain for patients with degenerative lumbar spinal stenosis. However, there is no culturally adapted SSS Questionnaire for use in mainland China. This was a prospective clinical validation study. The adaption was conducted according to International Quality of Life Assessment Project guidelines. To examine the psychometric properties of the adapted SC-SSS Questionnaire, a sample of 105 patients with lumbar spinal stenosis were included. Thirty-two patients were randomly selected to evaluate the test-retest reliability. Reliability assessment of the SC-SSS Questionnaire was determined by calculating Cronbach α and intraclass coefficient values. Concurrent validity was assessed by correlating SC-SSS Questionnaire scores with relevant domains of the 36-Item Short Form Health Survey. Cronbach α of the symptom severity scale, physical function scale, patients, and satisfaction scale of SC-SSS Questionnaire are 0.89, 0.86, 0.91, respectively, which revealed very good internal consistency. The test-retest reproducibility was found to be excellent with the intraclass correlation coefficient of 0.93, 0.91, and 0.95. In terms of concurrent validity, SC-SSS Questionnaire had good correlation with physical functioning and bodily pain of 36-Item Short Form Health Survey (r = 0.663, 0.653) and low correlation with mental health (r = 0.289). The physical function scale had good correlation with physical functioning of 36-Item Short Form Health Survey (r = 0.637), whereas the rest had moderate correlation. The satisfaction scale score was highly correlated with the change in the symptom severity (r = 0.71) and physical function (r = 0.68) scale score. The SC-SSS Questionnaire showed satisfactory reliability and validity in the evaluation of functionality in patients with lumbar spinal stenosis who are experiencing neurogenic claudication. It is simple and easy to use and can be recommended in clinical and research practice in mainland China. 3.
Salazar-Gutiérrez, María Luisa; Ochoa-Ponce, Cristina; Lona-Reyes, Juan Carlos; Gutiérrez-Íñiguez, Sara Ivonne
Reference methods for the quantification of the glomerular filtration rate (GFR) are difficult to use in clinical practice; formulas for evaluating GFR based on serum creatinine (SCr) and/or creatinine clearance are used. The aim of this study was to quantify the correlation and concordance of GFR with creatinine clearance in 24-hour urine (GFR24) and Schwartz and Schwartz updated formulas. Cross-sectional study involving healthy pediatric patients and with chronic kidney disease (CKD) from 5 to 16.9 years. Linear correlation between GFR 24 and two formulas was evaluated with the Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC). We studied 134 patients, of which 59.7% were male. Mean age was 10.8 years. The average GFR24 was 140.34ml/min/1.73m 2 ; 34.3% (n=46) had GFR <90ml/min/1.73m 2 . Moderate linear correlation between GFR24 and Schwartz (r= 0.63) and Schwartz updated (r= 0.65) formulas was observed. There was good concordance between the GFR24 and Schwartz (ICC= 0.77) and updated Schwartz (ICC= 0.77) formulas. Schwartz classical formula in patients with GFR24 ≥ 90ml/min/1.73m 2 estimated higher values, while Schwartz updated underestimated values. There is moderate correlation and good concordance between the GFR24 and Schwartz and Schwartz updated formulas. The concordance was better in patients with obesity and lower in women, patients with hyperfiltration and normal weight. Copyright © 2016 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.
Béliard, Sophie; Coudert, Mathieu; Valéro, René; Charbonnier, Laurie; Duchêne, Emilie; Allaert, François André; Bruckert, Éric
2012-12-01
The purpose of our study was to develop and validate a short food frequency questionnaire which could assess the nutritional lifestyles of hypercholesterolemic patients consulting in daily practice. The questionnaire explores 11 nutrient categories. Hundred and thirty-one patients were recruited for the construct validity and 58 patients for the external validity in La Pitié Hospital, Paris. The reference method used was the diet history. To measure the internal consistency and to test the sensibility to change on a large scale, the questionnaire was used in an observational study conducted in Spain in 1048 moderate hypercholesterolemic patients. Psychometric analyses included construct validity, internal consistency, test-retest reliability, external validity and sensibility to change. Validation of the questionnaire indicated a good internal consistency (Cronbach Coefficient Alpha at 0.69) and test-retest reliability (intraclass correlation coefficient=0.89). The correlation between the scores of the FFQ and those of the diet history was significant with a Pearson correlation coefficient at 0.3 (P=0.029). The comparison between the ranking of the patients showed an agreement of 72% with a kappa of 0.48 [0.10; 0.69]. The sensibility to change was good with a score evolution improving one and four months after nutrition advices: 28.2% of patients ranked in group 1 at inclusion versus 61.3% (P<0.0001) at one month and 75.2% (P<0.0001) at four months. In conclusion, we developed and validated a food questionnaire for hypercholesterolemic patients, which can be used as a therapeutic education tool in daily practice or in clinical research. Copyright © 2012. Published by Elsevier Masson SAS.
Lei, Pingguang; Lei, Guanghe; Tian, Jianjun; Zhou, Zengfen; Zhao, Miao; Wan, Chonghua
2014-10-01
This paper is aimed to develop the irritable bowel syndrome (IBS) scale of the system of Quality of Life Instruments for Chronic Diseases (QLICD-IBS) by the modular approach and validate it by both classical test theory and generalizability theory. The QLICD-IBS was developed based on programmed decision procedures with multiple nominal and focus group discussions, in-depth interview, and quantitative statistical procedures. One hundred twelve inpatients with IBS were used to provide the data measuring QOL three times before and after treatments. The psychometric properties of the scale were evaluated with respect to validity, reliability, and responsiveness employing correlation analysis, factor analyses, multi-trait scaling analysis, t tests and also G studies and D studies of generalizability theory analysis. Multi-trait scaling analysis, correlation, and factor analyses confirmed good construct validity and criterion-related validity when using SF-36 as a criterion. Test-retest reliability coefficients (Pearson r and intra-class correlation (ICC)) for the overall score and all domains were higher than 0.80; the internal consistency α for all domains at two measurements were higher than 0.70 except for the social domain (0.55 and 0.67, respectively). The overall score and scores for all domains/facets had statistically significant changes after treatments with moderate or higher effect size standardized response mean (SRM) ranging from 0.72 to 1.02 at domain levels. G coefficients and index of dependability (Ф coefficients) confirmed the reliability of the scale further with more exact variance components. The QLICD-IBS has good validity, reliability, responsiveness, and some highlights and can be used as the quality of life instrument for patients with IBS.
Nair, Rahul; Tsakos, Georgios; Yee Ting Fai, Robert
2016-12-01
To cross-culturally adapt the oral impacts on daily performance (OIDP) and assess its reliability and validity on Chinese-speaking community dwelling elderly Singaporeans. There are no previous reports of valid oral health-related quality of life instruments for elderly Singaporeans or perceived conditions associated with impacts reported in OIDP among the Singaporean elders. The OIDP was translated from English to Chinese and then back translated. The OIDP questionnaire along with questions related to overall quality of life and self-rated dental health was administered to 202 Chinese-speaking elderly Singaporeans by trained interviewers, and it was repeated after 1 month. Test-retest reliability was assessed using intraclass correlation coefficient; internal consistency was established using Cronbach's alpha, and construct validity using correlation coefficients with self-reported oral health-related and global quality of life measures. In addition, Kruskal-Wallis tests assessed differences in the OIDP score between different subjective health and global quality of life groups. The median age of participants was 75 years. About 19% reported oral impacts and difficulty eating was the most prevalent oral impact. Internal consistency was good with a Cronbach's alpha of 0.75, and the intraclass correlation coefficient was 0.75 (0.67-0.81). OIDP was significantly correlated with all measures of self-reported oral health and global ratings of quality of life, with correlation coefficients ranging between 0.15 and 0.52. Groups with worse perceptions about their health and quality of life had significantly higher OIDP scores. The OIDP showed successful reliability and validity for its use among Chinese-speaking older Singaporeans. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.
Assessment of the accuracy of a new tool for the screening of smartphone addiction.
Khoury, Julia Machado; de Freitas, André Augusto Corrêa; Roque, Marco Antônio Valente; Albuquerque, Maicon Rodrigues; das Neves, Maila de Castro Lourenço; Garcia, Frederico Duarte
2017-01-01
To translate, adapt and validate the Smartphone Addiction Inventory (SPAI) in a Brazilian population of young adults. We employed the translation and back-translation method for the adaptation of the Brazilian version SPAI (SPAI-BR). The sample consisted of 415 university students. Data was collected through an electronic questionnaire, which consisted of the SPAI-BR and the Goodman Criteria (gold standard). The retests were carried out 10-15 days after the initial tests with 130 individuals. The SPAI-BR maintained semantic, idiomatic and conceptual equivalences from the original scale. The Confirmatory Factor Analysis confirmed the One-factor model of the SPAI with good fit indexes (x2 = 767.861, CFI = 0.913, TLI = 0.905, RMSE = 0.061, WRMR = 1.465). The Kuder-Richardson Coefficient showed good internal consistency. The analysis of the ROC curve established an area under the curve of 86.38%. The Intraclass-Correlation Coefficient of 0.926 between the test and the retest demonstrated an excellent temporal stability. The high correlation between SPAI-BR and the Goodman Criteria (rs = 0.750) established the convergent validity. The SPAI-BR is a valid and reliable tool for the detection of Smartphone Addiction in Brazilian university students.
Test-retest reliability of the irrational performance beliefs inventory.
Turner, M J; Slater, M J; Dixon, J; Miller, A
2018-02-01
The irrational performance beliefs inventory (iPBI) was developed to measure irrational beliefs within performance domains such as sport, academia, business, and the military. Past research indicates that the iPBI has good construct, concurrent, and predictive validity, but the test-retest reliability of the iPBI has not yet been examined. Therefore, in the present study the iPBI was administered to university sport and exercise students (n = 160) and academy soccer athletes (n = 75) at three-time points. Time point two occurred 7 days after time point one, and time point three occurred 21 days after time point two. In addition, social desirability was also measured. Repeated-measures MANCOVAs, intra-class coefficients, and Pearson's (r) correlations demonstrate that the iPBI has good test-retest reliability, with iPBI scores remaining stable across the three-time points. Pearson's correlation coefficients revealed no relationships between the iPBI and social desirability, indicating that the iPBI is not highly susceptible to response bias. The results are discussed with reference to the continued usage and development of the iPBI, and future research recommendations relating to the investigation of irrational performance beliefs are proposed.
A satellite snow depth multi-year average derived from SSM/I for the high latitude regions
Biancamaria, S.; Mognard, N.M.; Boone, A.; Grippa, M.; Josberger, E.G.
2008-01-01
The hydrological cycle for high latitude regions is inherently linked with the seasonal snowpack. Thus, accurately monitoring the snow depth and the associated aerial coverage are critical issues for monitoring the global climate system. Passive microwave satellite measurements provide an optimal means to monitor the snowpack over the arctic region. While the temporal evolution of snow extent can be observed globally from microwave radiometers, the determination of the corresponding snow depth is more difficult. A dynamic algorithm that accounts for the dependence of the microwave scattering on the snow grain size has been developed to estimate snow depth from Special Sensor Microwave/Imager (SSM/I) brightness temperatures and was validated over the U.S. Great Plains and Western Siberia. The purpose of this study is to assess the dynamic algorithm performance over the entire high latitude (land) region by computing a snow depth multi-year field for the time period 1987-1995. This multi-year average is compared to the Global Soil Wetness Project-Phase2 (GSWP2) snow depth computed from several state-of-the-art land surface schemes and averaged over the same time period. The multi-year average obtained by the dynamic algorithm is in good agreement with the GSWP2 snow depth field (the correlation coefficient for January is 0.55). The static algorithm, which assumes a constant snow grain size in space and time does not correlate with the GSWP2 snow depth field (the correlation coefficient with GSWP2 data for January is - 0.03), but exhibits a very high anti-correlation with the NCEP average January air temperature field (correlation coefficient - 0.77), the deepest satellite snow pack being located in the coldest regions, where the snow grain size may be significantly larger than the average value used in the static algorithm. The dynamic algorithm performs better over Eurasia (with a correlation coefficient with GSWP2 snow depth equal to 0.65) than over North America (where the correlation coefficient decreases to 0.29). ?? 2007 Elsevier Inc. All rights reserved.
[Study on objectively evaluating skin aging according to areas of skin texture].
Shan, Gaixin; Gan, Ping; He, Ling; Sun, Lu; Li, Qiannan; Jiang, Zheng; He, Xiangqian
2015-02-01
Skin aging principles play important roles in skin disease diagnosis, the evaluation of skin cosmetic effect, forensic identification and age identification in sports competition, etc. This paper proposes a new method to evaluate the skin aging objectively and quantitatively by skin texture area. Firstly, the enlarged skin image was acquired. Then, the skin texture image was segmented by using the iterative threshold method, and the skin ridge image was extracted according to the watershed algorithm. Finally, the skin ridge areas of the skin texture were extracted. The experiment data showed that the average areas of skin ridges, of both men and women, had a good correlation with age (the correlation coefficient r of male was 0.938, and the correlation coefficient r of female was 0.922), and skin texture area and age regression curve showed that the skin texture area increased with age. Therefore, it is effective to evaluate skin aging objectively by the new method presented in this paper.
Yoshida, F; Topliss, J G
1996-08-01
Corneal permeability data taken from the literature were analyzed for possible quantitative relationships with physicochemical properties. Although a parabolic relationship was obtained with good correlation between lipophilicity, as expressed by the 1-octanol-water partition coefficients, log Poctanol (or the distribution coefficients, log D for ionizable compounds), and the permeability in individual analyses of compound classes such as beta-adrenoceptor blockers and steroids, the correlation was reduced when taken together. However, delta log P (i.e., log Poctanol-log Palkane) correlated inversely with the combined permeability data for beta-blockers and steroids and played a key role as a unifying variable. To a lesser extent, lipophilicity itself also contributes positively to corneal permeation. Even with the addition of miscellaneous compounds such as methanol and ibuprofen, the delta log P and lipophilicity terms were still significant. However, small molecules were likely to be underestimated, which is consistent with penetration via another pathway besides that governed by delta log P and lipophilicity.
Assessment of medical residents' satisfaction.
González-Martínez, José Francisco; García-García, José Antonio; Del Rosario Arnaud-Viñas, María; Arámbula-Morales, Enna Gabriela; Uriega-González Plata, Silvia; Mendoza-Guerrero, José Antonio
2011-01-01
Modern medical education is focused on students, and it is necessary to assess its level of satisfaction. A questionnaire was validated and we then conducted a study about the educational satisfaction level of medical residents of the Hospital General of Mexico. An observational, descriptive, cross-sectional and prospective study was conducted. A questionnaire of 21 items was validated and then applied to a representative sample of medical residents. Each item was evaluated with a scale from 0 to 10 and then gathered in groups: 0-5 = poor, 6-7 = average, 8 = good, 9 = very good, and 10 = excellent. Descriptive and inferential statistics were carried out using SPSS v.17.0. The questionnaire had internal validity with Cronbach's alpha >0.91 by item. Included in the study were 355 medical residents representing 37 different specialties. The performance perception of the ìheadî professors showed a wide heterogeneity: excellent (23.7%), very good (20.6%), good (16.9%), average (23.1%), poor (15.8%). Fourth-year residents and upward valued the educational performance higher (p = 0.001) as well as medical/surgical residents (p = 0.02). Intermediate-level residents valued the professor higher (p = 0.001), similar to students who were married or living with a partner (p <0.001). Upon contrasting the evaluation of the teacher's performance with the overall course performance, a linear, direct and significant correlation was obtained with Spearman's correlation coefficient = 0.78 and regression coefficient (p <0.001). We found a wide range of heterogeneity of results. Performance of the professors was the basic component to judge the quality of the residents' courses.
How well do clinical pain assessment tools reflect pain in infants?
Slater, Rebeccah; Cantarella, Anne; Franck, Linda; Meek, Judith; Fitzgerald, Maria
2008-06-24
Pain in infancy is poorly understood, and medical staff often have difficulty assessing whether an infant is in pain. Current pain assessment tools rely on behavioural and physiological measures, such as change in facial expression, which may not accurately reflect pain experience. Our ability to measure cortical pain responses in young infants gives us the first opportunity to evaluate pain assessment tools with respect to the sensory input and establish whether the resultant pain scores reflect cortical pain processing. Cortical haemodynamic activity was measured in infants, aged 25-43 wk postmenstrual, using near-infrared spectroscopy following a clinically required heel lance and compared to the magnitude of the premature infant pain profile (PIPP) score in the same infant to the same stimulus (n = 12, 33 test occasions). Overall, there was good correlation between the PIPP score and the level of cortical activity (regression coefficient = 0.72, 95% confidence interval [CI] limits 0.32-1.11, p = 0.001; correlation coefficient = 0.57). Of the different PIPP components, facial expression correlated best with cortical activity (regression coefficient = 1.26, 95% CI limits 0.84-1.67, p < 0.0001; correlation coefficient = 0.74) (n = 12, 33 test occasions). Cortical pain responses were still recorded in some infants who did not display a change in facial expression. While painful stimulation generally evokes parallel cortical and behavioural responses in infants, pain may be processed at the cortical level without producing detectable behavioural changes. As a result, an infant with a low pain score based on behavioural assessment tools alone may not be pain free.
Reliability and validity of the Chinese pediatric voice handicap index.
Liu, Kena; Liu, Shaofeng; Zhou, Zhou; Ren, Qinyi; Zhong, Jie; Luo, Renzhong; Qin, Huabiao; Zhang, Siyi; Ge, Pingjiang
2018-02-01
To evaluate the reliability and validity of the Chinese version of pediatric voice handicap index (pVHI). The original English version-pVHI was translated into Chinese. Parents of 52 children with voice dysphonia and 43 children with no history or symptoms of voice problems were asked to fill the Chinese pVHI questionnaires twice with an interval of 2 weeks. GRB (Grade, Roughness, Breathiness) scale was used for perceptual assessment by two otolaryngologists and one speech pathologist for each child's voice. The internal consistency was assessed using Cronbach's alpha coefficient. Pearson's correlation coefficient was used to evaluate the test-retest reliability. The Kendall's coefficient of concordance W was used to assess the consistency of GRB scores of 3 voice specialists. The nonparametric Mann-Whitney test was used to assess the differences between the dysphonia group and controls. The correlation between pVHI and GRB scores were assessed using Pearson's correlation coefficient. The internal consistency of total score and three subscales scores of Chinese pVHI were 0.788-0.944. The test-retest reliability was 0.631-0.887(P < .001). The pVHI scores of control group significantly were lower than the pathological group (P = .000). The GRB scores of 3 voice specialists have an excellent consistency (W = 0.694-0.807, P = .000). The pVHI scores positively correlated with GRB assessment (P < .01). The Chinese version of pVHI had a good reliability and validity. It can be applicable and useful supplementary tool for evaluating parents' perception of their children's dysphonia. Copyright © 2017. Published by Elsevier B.V.
Velasco-Barona, Cecilio; Cervantes-Coste, Guadalupe; Mendoza-Schuster, Erick; Corredor-Ortega, Claudia; Casillas-Chavarín, Nadia L; Silva-Moreno, Alejandro; Garza-León, Manuel; Gonzalez-Salinas, Roberto
2018-06-01
To compare the biometric measurements obtained from the Verion Image-Guided System to those obtained by auto-refracto-keratometer in normal eyes. This is a prospective, observational, comparative study conducted at the Asociación para Evitar la Ceguera en México I.A.P., Mexico. Three sets of keratometry measurements were obtained using the image-guided system to assess the coefficient of variation, the within-subject standard deviation and intraclass correlation coefficient (ICC). A paired Student t test was used to assess statistical significance between the Verion and the auto-refracto-keratometer. A Pearson's correlation coefficient (r) was obtained for all measurements, and the level of agreement was verified using Bland-Altman plots. The right eyes of 73 patients were evaluated by each platform. The Verion coefficient of variation was 0.3% for the flat and steep keratometry, with the ICC being greater than 0.9 for all parameters measured. Paired t test showed statistically significant differences between groups (P = 0.0001). A good correlation was evidenced for keratometry values between platforms (r = 0.903, P = 0.0001 for K1, and r = 0.890, P = 0.0001). Bland-Altman plots showed a wide data spread for all variables. The image-guided system provided highly repeatable corneal power and keratometry measurements. However, significant differences were evidenced between the two platforms, and although values were highly correlated, they showed a wide data spread for all analysed variables; therefore, their interchangeable use for biometry assessment is not advisable.
Bahouq, Hanane; Rostom, Samira; Bahiri, Rachid; Hakkou, Jinane; Aissaoui, Nawal; Hajjaj-Hassouni, Najia
2012-12-01
Fatigue is a frequent symptom during ankylosing spondylitis (AS) often under estimated which needs to be measured properly with respect to its intensity by appropriate measures, such as the multidimensional assessment of fatigue (MAF). The aims of this study were to translate into the classic Arabic version of the MAF questionnaire and to validate its use for assessing fatigue in Moroccan patients with AS. The MAF contains 16 items with a global fatigue index (IGF). The MAF was translated and back-translated to arabic, pretested and reviewed by a committee following the Guillemin criteria (J Clin Epidemiol 46:1417-1432, 1993). It was then validate on 110 Moroccan patients with AS. Reliability for the 3-day test-retest was assessed using internal consistency by Cronbach's alpha coefficient and the intra-class correlation coefficient (ICC). External construct validity was assessed by correlation with pain, activity of disease and other keys variable. The reproducibility of the 15 items was satisfactory with a kappa statistics of agreement superior to 0.6. The ICC for IGF score reproducibility was good and reached 0.98 (IC 95%, 0.96-0.99). The internal consistency was at 0.991 with Cronbach's alpha coefficient. The construct validity showed a positive correlation between MAF and the axial (r = 0.34) and peripheral (r = 0.32) visual analogical scale, the Bath ankylosing spondylitis disease activity index (BASDAI) (r = 0.77), the first item of BASDAI (r = 0.85), the functional disability by the Bath ankylosing spondylitis functional index (r = 0.64), the erythrocyte sedimentation rate (r = 0.43) and the C reactive protein (r = 0.30) (for all P < 0.001). There was no statistical correlation between MAF and the other variables. The Arabic version of the MAF has good comprehensibility, internal consistency, reliability and validity for the evaluation of Arabic speaking patients with AS.
Li, D H; Wang, W; Li, X; Gao, Y L; Liu, D H; Liu, D L; Xu, W D
2017-01-01
The International Hip Outcome Tool (iHOT-33) is a questionnaire designed for young, active patients with hip disorders. It has proven to be a highly reliable and valid questionnaire. The main purpose of our study was to adapt the iHOT-33 questionnaire into simplified Chinese and to assess its psychometric properties in Chinese patients. The iHOT-33 was cross culturally adapted into Chinese and 138 patients completed the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the EuroQol-5D (EQ-5D), and the Chinese version of the iHOT-33(SC-iHOT-33) pre- or postoperatively within 6 months' follow-up. The Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) were calculated to assess the reliability, validity, and responsiveness of the SC-iHOT-33, respectively. Total Cronbach's alpha was 0.965, which represented excellent internal consistency of the SC-iHOT-33. The ICC ranges from 0.866 to 0.929, which shows excellent test-retest reliability. The subscales of SC-iHOT-33 had the highest correlation coefficient (r = 0.812) with the physical function subscales of the WOMAC, as well as good correlation between the social/emotional subscale of the SC-iHOT-33 and the EQ-5D (r = 0.740, r = 0.743). No floor or ceiling effects were found. The ES and SRM values indicated good responsiveness of 2.44 and 2.67, respectively. The SC-iHOT-33 questionnaire is reliable, valid, and responsive for the evaluation of young, Chinese, active patients with hip disorders. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Blackmon, Jaime E; Liptak, Cori; Recklitis, Christopher J
2017-03-01
Three previously developed short forms of the Beck Depression Inventory-Youth (BDI-Y) were validated against the standard 20-item BDI-Y; 168 adolescent survivors completed the standard and short-form versions of the BDI-Y. The short forms were evaluated for internal consistency and compared with the standard BDI-Y using correlation coefficients and receiver operating characteristic curve analyses. The three short forms had good internal consistency (α > 0.85), high correlations with the total BDI-Y scale (r > 0.85), and good discrimination compared with the standard BDI-Y cutoff score (area under the ROC curve >0.95). Consistent with prior findings, strong psychometric properties of an eight-item short form support its use as a screening measure for adolescent cancer survivors.
Mobile detection system to evaluate reactive hyperemia using radionuclide plethysmography.
Harel, François; Ngo, Quam; Finnerty, Vincent; Hernandez, Edgar; Khairy, Paul; Dupuis, Jocelyn
2007-08-01
We validated a novel mobile detection system to evaluate reactive hyperemia using the radionuclide plethysmography technique. Twenty-six subjects underwent simultaneously radionuclide plethysmography with strain gauge plethysmography. Strain gauge and radionuclide methods showed excellent reproducibility with intraclass correlation coefficients of 0.96 and 0.89 respectively. There was also a good correlation of flows between the two methods during reactive hyperemia (r = 0.87). We conclude that radionuclide plethysmography using this mobile detection system is a non-invasive alternative to assess forearm blood flow and its dynamic variations during reactive hyperemia.
In vitro burn model illustrating heat conduction patterns using compressed thermal papers.
Lee, Jun Yong; Jung, Sung-No; Kwon, Ho
2015-01-01
To date, heat conduction from heat sources to tissue has been estimated by complex mathematical modeling. In the present study, we developed an intuitive in vitro skin burn model that illustrates heat conduction patterns inside the skin. This was composed of tightly compressed thermal papers with compression frames. Heat flow through the model left a trace by changing the color of thermal papers. These were digitized and three-dimensionally reconstituted to reproduce the heat conduction patterns in the skin. For standardization, we validated K91HG-CE thermal paper using a printout test and bivariate correlation analysis. We measured the papers' physical properties and calculated the estimated depth of heat conduction using Fourier's equation. Through contact burns of 5, 10, 15, 20, and 30 seconds on porcine skin and our burn model using a heated brass comb, and comparing the burn wound and heat conduction trace, we validated our model. The heat conduction pattern correlation analysis (intraclass correlation coefficient: 0.846, p < 0.001) and the heat conduction depth correlation analysis (intraclass correlation coefficient: 0.93, p < 0.001) showed statistically significant high correlations between the porcine burn wound and our model. Our model showed good correlation with porcine skin burn injury and replicated its heat conduction patterns. © 2014 by the Wound Healing Society.
CORRELATION OF HARD X-RAY AND WHITE LIGHT EMISSION IN SOLAR FLARES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhar, Matej; Krucker, Säm; Battaglia, Marina
A statistical study of the correlation between hard X-ray and white light emission in solar flares is performed in order to search for a link between flare-accelerated electrons and white light formation. We analyze 43 flares spanning GOES classes M and X using observations from the Reuven Ramaty High Energy Solar Spectroscopic Imager and Helioseismic and Magnetic Imager. We calculate X-ray fluxes at 30 keV and white light fluxes at 6173 Å summed over the hard X-ray flare ribbons with an integration time of 45 s around the peak hard-X ray time. We find a good correlation between hard X-raymore » fluxes and excess white light fluxes, with a highest correlation coefficient of 0.68 for photons with energy of 30 keV. Assuming the thick target model, a similar correlation is found between the deposited power by flare-accelerated electrons and the white light fluxes. The correlation coefficient is found to be largest for energy deposition by electrons above ∼50 keV. At higher electron energies the correlation decreases gradually while a rapid decrease is seen if the energy provided by low-energy electrons is added. This suggests that flare-accelerated electrons of energy ∼50 keV are the main source for white light production.« less
Nomura, N; Saito, K; Ikeda, M; Yuasa, S; Pastore, M; Chabert, C; Kono, E; Sakai, A; Tanaka, H; Ikemoto, T; Takubo, T
2015-08-01
We evaluated the basic performance of Microsemi CRP, an unique automated hematology analyzer which can simultaneously measure CBC including 3-part WBC differential (3-Diff) and CRP using whole blood treated with EDTA-2K anticoagulant. We found that it produced generally the acceptable results for all parameters performed (repeatability, reproducibility, linearity, interference effect, carry over, and correlation) using control materials, fresh human whole bloods, and serum samples. CBC data examined using Microsemi CRP showed the good correlation with the previous model, Micros CRP200 (r ≧ 0.9), and also those obtained using the routine analyzer, ADVIA 2120i (r ≧ 0.989). Concerning the 3-Diff, both GRA (%) and LYM (%) showed the excellent correlation coefficient between Microsemi CRP and Micros CRP200 (r ≧ 0.992) as well as ADVIA 2120i (r ≧ 0.957). MON (%) showed good correlation between Microsemi CRP and Micros CRP200 (r = 0.959), but lower correlation between Microsemi CRP and ADVIA 2120 i (r = 0.471). CRP data showed the good correlation with HITACHI7600 (r ≧ 0.997) and Micros CRP200 (r ≧ 0.997). From these findings, we concluded that Microsemi CRP seemed the convenient laboratory analyzer in the setting of point of care testing (POCT) especially at NICU or primary care unit. © 2014 John Wiley & Sons Ltd.
The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.
Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene
2012-06-01
INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.
Guess, Trent M; Razu, Swithin; Jahandar, Amirhossein; Skubic, Marjorie; Huo, Zhiyu
2017-04-01
The Microsoft Kinect is becoming a widely used tool for inexpensive, portable measurement of human motion, with the potential to support clinical assessments of performance and function. In this study, the relative osteokinematic Cardan joint angles of the hip and knee were calculated using the Kinect 2.0 skeletal tracker. The pelvis segments of the default skeletal model were reoriented and 3-dimensional joint angles were compared with a marker-based system during a drop vertical jump and a hip abduction motion. Good agreement between the Kinect and marker-based system were found for knee (correlation coefficient = 0.96, cycle RMS error = 11°, peak flexion difference = 3°) and hip (correlation coefficient = 0.97, cycle RMS = 12°, peak flexion difference = 12°) flexion during the landing phase of the drop vertical jump and for hip abduction/adduction (correlation coefficient = 0.99, cycle RMS error = 7°, peak flexion difference = 8°) during isolated hip motion. Nonsagittal hip and knee angles did not correlate well for the drop vertical jump. When limited to activities in the optimal capture volume and with simple modifications to the skeletal model, the Kinect 2.0 skeletal tracker can provide limited 3-dimensional kinematic information of the lower limbs that may be useful for functional movement assessment.
Performance and Loads Correlation of a UH-60A Slowed Rotor at High Advance Ratios
NASA Technical Reports Server (NTRS)
Kottapalli, Sesi B.
2012-01-01
Measured data from the slowed rotor part of the 2010 UH-60A Airloads Rotor test in the NASA Ames 40- by 80- Foot Wind Tunnel are compared with CAMRAD II calculations. The emphasis in this initial study is to correlate overall trends. This analytical effort considers advance ratios from 0.3 to 1.0, with the rotor rotational speed at 40%NR. The rotor performance parameters considered are the thrust coefficient, power coefficient, L/DE, torque, and H-force. The blade loads considered are the half peak-to-peak, mid-span and outboard torsion, flatwise, and chordwise moments, and the pitch link load. For advance ratios . 0.7, the overall trends for the performance and loads (excluding the pitch link load) could be captured, but with substantial overprediction or underprediction. The correlation gradually deteriorates as the advance ratio is increased and for advance ratios . 0.8 there is no correlation. The pitch link load correlation is not good. There is considerable scope for improvement in the prediction of the blade loads. Considering the modeling complexity associated with the unconventional operating condition under consideration, the current predictive ability to capture overall trends is encouraging.
Validation of general job satisfaction in the Korean Labor and Income Panel Study.
Park, Shin Goo; Hwang, Sang Hee
2017-01-01
The purpose of this study is to assess the validity and reliability of general job satisfaction (JS) in the Korean Labor and Income Panel Study (KLIPS). We used the data from the 17th wave (2014) of the nationwide KLIPS, which selected a representative panel sample of Korean households and individuals aged 15 or older residing in urban areas. We included in this study 7679 employed subjects (4529 males and 3150 females). The general JS instrument consisted of five items rated on a scale from 1 (strongly disagree) to 5 (strongly agree). The general JS reliability was assessed using the corrected item-total correlation and Cronbach's alpha coefficient. The validity of general JS was assessed using confirmatory factor analysis (CFA) and Pearson's correlation. The corrected item-total correlations ranged from 0.736 to 0.837. Therefore, no items were removed. Cronbach's alpha for general JS was 0.925, indicating excellent internal consistency. The CFA of the general JS model showed a good fit. Pearson's correlation coefficients for convergent validity showed moderate or strong correlations. The results obtained in our study confirm the validity and reliability of general JS.
Evaluation of Lumipulse® G1200 for the measurement of six tumor markers: Comparison with AIA® 2000.
de Rancher, Marie-Aude Robert; Oudart, Jean-Baptiste; Maquart, François-Xavier; Monboisse, Jean Claude; Ramont, Laurent
2016-11-01
Tumor marker assays are daily practiced, for screening and follow up of cancers. Interassay precision is an important parameter for the interpretation of the kinetics of the markers, in order to conclude to the efficiency or failure of treatment. The aim of this study was to compare two automated Immunoassay analyzers, Lumipulse® G1200 and AIA® 2000. Both analyzers used an immunoassay system but with different antibodies. Six tumor markers commonly used were studied: AFP, PSA, CA 19-9, CA 15-3, CA 125 and CEA. 253 samples have been collected over a period of one month and analyzed by both analyzers. Regression of Passing-Badblock and Bland-Altman diagram were used to analyze the results for AFP (n=36), PSA (n=39), CA-125 (n=40), CA 15-3 (n=40), CA 19-9 (n=46) and CEA (n=52) were performed. Analytical performances of Lumipulse® G1200 highlighted the good inter-run and intra-run precision of the analyzer. We obtained a good correlation coefficient between Lumipulse G1200® and AIA 2000®, >0.96 for most markers except CA 19-9 which provided a correlation coefficient significantly lower than that obtained with other markers. The concordance for all markers was >94% except for CA 19-9 (83.7%). This study showed a good correlation between the two analyzers and, therefore, a transfer from one analyzer to the other is possible for the different markers studied. However, we found here the classical difficulty to transfer this type of analysis, due to the absence of method standardization. This difficulty was particularly illustrated by CA19-9. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Song, Huiying; Vanderheyden, Yoachim; Adams, Erwin; Desmet, Gert; Cabooter, Deirdre
2016-07-15
Diffusion plays an important role in all aspects of band broadening in chromatography. An accurate knowledge of molecular diffusion coefficients in different mobile phases is therefore crucial in fundamental column performance studies. Correlations available in literature, such as the Wilke-Chang equation, can provide good approximations of molecular diffusion under reversed-phase conditions. However, these correlations have been demonstrated to be less accurate for mobile phases containing a large percentage of acetonitrile, as is the case in hydrophilic interaction liquid chromatography. A database of experimentally measured molecular diffusion coefficients of some 45 polar and apolar compounds that are frequently used as test molecules under hydrophilic interaction liquid chromatography and reversed-phase conditions is therefore presented. Special attention is given to diffusion coefficients of polar compounds obtained in large percentages of acetonitrile (>90%). The effect of the buffer concentration (5-10mM ammonium acetate) on the obtained diffusion coefficients is investigated and is demonstrated to mainly influence the molecular diffusion of charged molecules. Diffusion coefficients are measured using the Taylor-Aris method and hence deduced from the peak broadening of a solute when flowing through a long open tube. The validity of the set-up employed for the measurement of the diffusion coefficients is demonstrated by ruling out the occurrence of longitudinal diffusion, secondary flow interactions and extra-column effects, while it is also shown that radial equilibration in the 15m long capillary is effective. Copyright © 2016 Elsevier B.V. All rights reserved.
Development and validation of a fatigue assessment scale for U.S. construction workers.
Zhang, Mingzong; Sparer, Emily H; Murphy, Lauren A; Dennerlein, Jack T; Fang, Dongping; Katz, Jeffrey N; Caban-Martinez, Alberto J
2015-02-01
To develop a fatigue assessment scale and test its reliability and validity for commercial construction workers. Using a two-phased approach, we first identified items (first phase) for the development of a Fatigue Assessment Scale for Construction Workers (FASCW) through review of existing scales in the scientific literature, key informant interviews (n = 11) and focus groups (three groups with six workers each) with construction workers. The second phase included assessment for the reliability, validity, and sensitivity of the new scale using a repeated-measures study design with a convenience sample of construction workers (n = 144). Phase one resulted in a 16-item preliminary scale that after factor analysis yielded a final 10-item scale with two sub-scales ("Lethargy" and "Bodily Ailment"). During phase two, the FASCW and its subscales demonstrated satisfactory internal consistency (alpha coefficients were FASCW [0.91], Lethargy [0.86] and Bodily Ailment [0.84]) and acceptable test-retest reliability (Pearson Correlations Coefficients: 0.59-0.68; Intraclass Correlation Coefficients: 0.74-0.80). Correlation analysis substantiated concurrent and convergent validity. A discriminant analysis demonstrated that the FASCW differentiated between groups with arthritis status and different work hours. The 10-item FASCW with good reliability and validity is an effective tool for assessing the severity of fatigue among construction workers. © 2015 Wiley Periodicals, Inc.
Zhang, Yong-Hong; Xia, Zhi-Ning; Qin, Li-Tang; Liu, Shu-Shen
2010-09-01
The objective of this paper is to build a reliable model based on the molecular electronegativity distance vector (MEDV) descriptors for predicting the blood-brain barrier (BBB) permeability and to reveal the effects of the molecular structural segments on the BBB permeability. Using 70 structurally diverse compounds, the partial least squares regression (PLSR) models between the BBB permeability and the MEDV descriptors were developed and validated by the variable selection and modeling based on prediction (VSMP) technique. The estimation ability, stability, and predictive power of a model are evaluated by the estimated correlation coefficient (r), leave-one-out (LOO) cross-validation correlation coefficient (q), and predictive correlation coefficient (R(p)). It has been found that PLSR model has good quality, r=0.9202, q=0.7956, and R(p)=0.6649 for M1 model based on the training set of 57 samples. To search the most important structural factors affecting the BBB permeability of compounds, we performed the values of the variable importance in projection (VIP) analysis for MEDV descriptors. It was found that some structural fragments in compounds, such as -CH(3), -CH(2)-, =CH-, =C, triple bond C-, -CH<, =C<, =N-, -NH-, =O, and -OH, are the most important factors affecting the BBB permeability. (c) 2010. Published by Elsevier Inc.
Liu, Shu-Shen; Qin, Li-Tang; Liu, Hai-Ling; Yin, Da-Qiang
2008-02-01
Molecular electronegativity distance vector (MEDV) derived directly from the molecular topological structures was used to describe the structures of 122 nonionic organic compounds (NOCs) and a quantitative relationship between the MEDV descriptors and the bioconcentration factors (BCF) of NOCs in fish was developed using the variable selection and modeling based on prediction (VSMP). It was found that some main structural factors influencing the BCFs of NOCs are the substructures expressed by four atomic types of nos. 2, 3, 5, and 13, i.e., atom groups -CH(2)- or =CH-, -CH< or =C<, -NH(2), and -Cl or -Br where the former two groups exist in the molecular skeleton of NOC and the latter three groups are related closely to the substituting groups on a benzene ring. The best 5-variable model, with the correlation coefficient (r(2)) of 0.9500 and the leave-one-out cross-validation correlation coefficient (q(2)) of 0.9428, was built by multiple linear regressions, which shows a good estimation ability and stability. A predictive power for the external samples was tested by the model from the training set of 80 NOCs and the predictive correlation coefficient (u(2)) for the 42 external samples in the test set was 0.9028.
Performance of chromatographic systems to model soil-water sorption.
Hidalgo-Rodríguez, Marta; Fuguet, Elisabet; Ràfols, Clara; Rosés, Martí
2012-08-24
A systematic approach for evaluating the goodness of chromatographic systems to model the sorption of neutral organic compounds by soil from water is presented in this work. It is based on the examination of the three sources of error that determine the overall variance obtained when soil-water partition coefficients are correlated against chromatographic retention factors: the variance of the soil-water sorption data, the variance of the chromatographic data, and the variance attributed to the dissimilarity between the two systems. These contributions of variance are easily predicted through the characterization of the systems by the solvation parameter model. According to this method, several chromatographic systems besides the reference octanol-water partition system have been selected to test their performance in the emulation of soil-water sorption. The results from the experimental correlations agree with the predicted variances. The high-performance liquid chromatography system based on an immobilized artificial membrane and the micellar electrokinetic chromatography systems of sodium dodecylsulfate and sodium taurocholate provide the most precise correlation models. They have shown to predict well soil-water sorption coefficients of several tested herbicides. Octanol-water partitions and high-performance liquid chromatography measurements using C18 columns are less suited for the estimation of soil-water partition coefficients. Copyright © 2012 Elsevier B.V. All rights reserved.
Cross-Cultural Adaptation and Validation of the Back Beliefs Questionnaire to the Arabic Language.
Alamrani, Samia; Alsobayel, Hana; Alnahdi, Ali H; Moloney, Niamh; Mackey, Martin
2016-06-01
Translation, cross-cultural adaptation, and psychometric testing. To translate the Back Beliefs Questionnaire (BBQ) into Arabic and investigate its psychometric properties in an Arabic-speaking sample of individuals with low back pain (LBP). Back pain beliefs are associated with pain chronicity and disability in people with LBP. The BBQ is a recognized and frequently used tool for measuring these beliefs. To date the BBQ has not been translated into Arabic. The English version of the BBQ was translated and culturally adapted into Arabic (BBQ-Ar) according to published guidelines. The BBQ-Ar was then tested in a sample of 115 Arabic-speaking individuals with LBP. Reliability was evaluated through internal consistency (Cronbach α) and test-retest reliability (intraclass correlation coefficient), the latter in a subgroup of 25. Construct validity was assessed using exploratory factor analysis and by examining the correlation between the BBQ-Ar, the Oswestry Disability Index and a Numerical Pain Rating Scale. Internal consistency of the BBQ-Ar was good (Cronbach α = 0.77). Test-retest reliability was good (intraclass correlation coefficient [2,1] = 0.88). Exploratory factor analysis revealed a three-factor structure, explaining 46% of total variance, with the first factor alone explaining 24%. Eight of the nine scoring items were loaded on the first factor thus forming a unidimensional scale. A significant negative correlation was found between Oswestry Disability Index and BBQ-Ar scores (r = -0.307; P < 0.01), whereas no significant correlation was found between BBQ-Ar and Pain Rating Scale scores. No floor or celling effects were observed. The BBQ-Ar is a valid and reliable tool that can be used to assess back pain beliefs in Arabic-speaking individuals. N/A.
Tsugawa, Yusuke; Ohbu, Sadayoshi; Cruess, Richard; Cruess, Sylvia; Okubo, Tomoya; Takahashi, Osamu; Tokuda, Yasuharu; Heist, Brian S; Bito, Seiji; Itoh, Toshiyuki; Aoki, Akiko; Chiba, Tsutomu; Fukui, Tsuguya
2011-08-01
Despite the growing importance of and interest in medical professionalism, there is no standardized tool for its measurement. The authors sought to verify the validity, reliability, and generalizability of the Professionalism Mini-Evaluation Exercise (P-MEX), a previously developed and tested tool, in the context of Japanese hospitals. A multicenter, cross-sectional evaluation study was performed to investigate the validity, reliability, and generalizability of the P-MEX in seven Japanese hospitals. In 2009-2010, 378 evaluators (attending physicians, nurses, peers, and junior residents) completed 360-degree assessments of 165 residents and fellows using the P-MEX. The content validity and criterion-related validity were examined, and the construct validity of the P-MEX was investigated by performing confirmatory factor analysis through a structural equation model. The reliability was tested using generalizability analysis. The contents of the P-MEX achieved good acceptance in a preliminary working group, and the poststudy survey revealed that 302 (79.9%) evaluators rated the P-MEX items as appropriate, indicating good content validity. The correlation coefficient between P-MEX scores and external criteria was 0.78 (P < .001), demonstrating good criterion-related validity. Confirmatory factor analysis verified high path coefficient (0.60-0.99) and adequate goodness of fit of the model. The generalizability analysis yielded a high dependability coefficient, suggesting good reliability, except when evaluators were peers or junior residents. Findings show evidence of adequate validity, reliability, and generalizability of the P-MEX in Japanese hospital settings. The P-MEX is the only evaluation tool for medical professionalism verified in both a Western and East Asian cultural context.
Li, Xiao-yun; Wang, Jia-hua; Huang, Ya-wei; Han, Dong-hai
2011-03-01
Near infrared diffuse reflectance spectroscopy calibrations of fat, protein and DM in raw milk were studied with partial least-squares (PLS) regression using portable short-wave near infrared spectrometer. The results indicated that good calibrations of fat and DM were found, the correlation coefficients were all 0.98, the RMSEC were 0.187 and 0.217, RMSEP were 0.187 and 0.296, the RPDs were 5.02 and 3.20 respectively; the calibration of protein needed to be improved but can be used for practice, the correlation coefficient was 0.95, RMSEC was 0.105, RMSEP was 0.120, and RPD was 2.60. Furthermore, the measuring accuracy was improved by analyzing the correction relation of fat and DM in raw milk This study will probably provide a new on-site method for nondestructive and rapid measurement of milk.
The Study of Micro-Pressure Inner-Loop Bioreactor Oxygen Mass Transfer Characteristics
NASA Astrophysics Data System (ADS)
Wan, L. G.; Lin, Q.; Bian, D. J.; Ren, Q. K.; Xiao, Y. B.; Lu, W. X.
2018-03-01
The oxygen mass transfer characteristics in a Micro-Pressure Inner-Loop bioreactor (MPR) were studied by clean water oxygenation experiment, the results show that when the aeration adopt by 0.1, 0.2, 0.4, 0.6 m3·h-1, respectively, the oxygen mass transfer coefficient KLa(20) in the reactor increases with the increase of the aeration. KLa(20) shows a good linear correlation with the aeration. The rate is 0.2128 h·m-3·min-1 and the correlation coefficient R=0.993. However, the trend of EO2 increases first and then decreases with the increase of aeration. When the aeration increased to 0.4 m3·h-1, the EO2 reaches the maximum. If aeration increases constantly, EO2 begin to decrease excessive aeration may lead to an increase in energy waste during reactor operation.
NASA Technical Reports Server (NTRS)
Okong'o, Nora; Bellan, Josette
2005-01-01
Models for large eddy simulation (LES) are assessed on a database obtained from direct numerical simulations (DNS) of supercritical binary-species temporal mixing layers. The analysis is performed at the DNS transitional states for heptane/nitrogen, oxygen/hydrogen and oxygen/helium mixing layers. The incorporation of simplifying assumptions that are validated on the DNS database leads to a set of LES equations that requires only models for the subgrid scale (SGS) fluxes, which arise from filtering the convective terms in the DNS equations. Constant-coefficient versions of three different models for the SGS fluxes are assessed and calibrated. The Smagorinsky SGS-flux model shows poor correlations with the SGS fluxes, while the Gradient and Similarity models have high correlations, as well as good quantitative agreement with the SGS fluxes when the calibrated coefficients are used.
Wang, W; Liu, L; Chang, X; Jia, Z Y; Zhao, J Z; Xu, W D
2016-10-19
The Lysholm Knee Score (LKS) is widely used and is one of the most effective questionnaires employed to assess knee injuries. Although LKS has been translated into multiple languages, there is no Chinese version even though China has the largest population of patients with knee-joint injuries. The objective of our study was to develop the Chinese version of LKS (C-LKS) and assess its reliability, validity and responsiveness in Chinese patients with anterior cruciate ligament (ACL) injuries. Study participants were mainly recruited among patients with ACL injuries scheduled for arthroscopic ACL reconstruction at our hospital. First, we developed the C-LKS in a five-step translation and cross-cultural adaptation procedure. Next, we calculated the Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) to evaluate the reliability, validity, and responsiveness of C-LKS respectively. Overall, 126 patients with ACL injuries successfully completed the questionnaires. Acceptable internal consistency (Cronbach's alpha = 0.726) as well as excellent test-retest reliability (ICC = 0.935) was found for C-LKS. Good or moderate correlation (r = 0.514-0.837) was determined among C-LKS and International Knee Documentation Committee Subjective Knee Form (IKDC), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), physical subscales of SF-36; C-LKS also had fair or moderate correlation (r = 0.207-0.462) with the other subscales of SF-36, which adequately illustrated that good validity was included in C-LKS. In addition, good responsiveness was also observed in C-LKS (ES = 1.36,SRM = 1.26). We have shown that our developed C-LKS questionnaire is reliable, valid and responsible for the evaluation of Chinese-speaking patients with ACL injuries and it would be an effective instrument.
Wu, Y Z; Wang, W J; Feng, N P; Chen, B; Li, G C; Liu, J W; Liu, H L; Yang, Y Y
2016-07-06
To evaluate the validity, reliability, and acceptability of the brief version of the self-management knowledge, attitude, and behavior (KAB) assessment scale for diabetes patients. Diabetes patients who were managed at the Xinkaipu Community Health Service Center of Tianxin in Changsha, Hunan Province were selected for survey by cluster sampling. A total of 350 diabetes patients were surveyed using the brief scale to collect data on knowledge, attitudes, and behaviors of self-management. Content validity was evaluated by Pearson correlation coefficient between the brief scale and subscales of knowledge, attitude, and behavior. Structure validity was evaluated by factor analysis, and discrimination validity was evaluated by an independent sample t-test between the high-score and low-score groups. Reliability was tested by internal consistency reliability and split-half reliability. The evaluation indexes of internal consistency reliability were Cronbach's α coefficients, θ coefficient, and Ω coefficient. Acceptability was evaluated by valid response rate and completion time of the brief scale. A total of 346(98.9%) valid questionnaires were returned, with average survey time of (11.43±3.4) minutes. Average score of the brief scale was 78.85 ± 11.22; scores of the knowledge, attitude, and behavior subscales were 16.45 ± 4.42, 21.33 ± 2.03, and 41.07 ± 8.34, respectively. Pearson correlation coefficients between the brief scale and the knowledge, attitude, and behavior subscales were 0.92, 0.42, and 0.60, respectively; P-values were all less than 0.01, indicating that the face validity and content validity of the brief scale were achieved to a good level. The common factor cumulative variance contribution rate of the brief scale and three subscales was from 53.66% to 61.75%, which achieved more than 50% of the approved standard. There were 11 common factors; 41 of the total 42 items had factor loadings above 0.40 in their relevant common factor, indicating that the brief scale and three subscales had good construct validity. Patients were divided into a high-score group and a low-score group, then scores of the brief scale and three subscales were compared between the groups using a t-test. The results were all significant, indicating that the brief scale and three subscales had good discriminate validity. Mean scores of the brief scale and three subscales of the high-score group were 91.55±6.81, 19.51±2.17, 22.74±1.88, and 49.30±6.20, respectively; these were higher than the low-score group (65.89±5.79, 12.29±4.76, 20.22±1.88, and 33.39±6.17, respectively) with t-values 27.76, 13.31, 9.20, and 17.56 (P-values were less than 0.001). The Cronbach's α coefficient, θ coefficient, Ω coefficient, and split-half reliability of the brief scale were 0.83, 0.87, 0.96, and 0.84, respectively. These values for the three subscales were all above 0.70, except for the θ coefficient of the attitude subscale with 0.64, indicating that the brief scale and three subscales had acceptable internal consistency reliability. The brief version of the diabetes self-management knowledge, attitude, and behavior assessment scale showed good acceptability, validity, and reliability, to responsibly evaluate self-management KAB among patients with diabetes.
Ceria-Ulep, Clementina D.; Grove, John; Chen, Randi; Masaki, Kamal H.; Rodriguez, Beatriz L.; Donlon, Tim A.; Guralnik, Jack; Willcox, Bradley J.; Willcox, D. Craig; Nigg, Claudio; Curb, J. David
2010-01-01
Objectives. To investigate the reliability and correlations with age of the balance components of the EPESE, NHANES, and the Good Balance Platform System (GBPS) in a normal population of adults. Design. Cross-sectional. Setting. Urban Medical Center in the Pacific. Participants. A random sample of 203 healthy offspring of Honolulu Heart Program participants, ages 38–71. Measurements. Subjects were examined twice at visits one week apart using the balance components of the EPESE, NHANES, and the good balance system tests. Results. The EPESE and NHANES batteries of tests were not sufficiently challenging to allow successful discrimination among subjects in good health, even older subjects. The GBPS allowed objective quantitative measurements, but the test-retest correlations generally were not high. The GBPS variables correlated with age only when subjects stood on a foam pad; they also were correlated with anthropometric variables. Conclusion. Both EPESE and NHANES balance tests were too easy for healthy subjects. The GBPS had generally low reliability coefficients except for the most difficult testing condition (foam pad, eyes closed). Both height and body fat were associated with GBPS scores, necessitating adjusting for these variables if using balance as a predictor of future health. PMID:21437003
Narro-Robles, J; Gutiérrez-Avila, J H
1997-01-01
To determine the correlation between alcohol consumption and mortality from liver cirrhosis in Mexico. Analysis of the ecological correlation between the patterns of alcohol consumption determined by the National Addiction Survey in 1993 and mortality by liver cirrhosis, in the period between 1971-1993, in the eight regions in which the country was divided. To determine level of correlation, the Pearson and Spearman coefficients were calculated. Significant correlations were only found with the prevalence of spirits and pulque drinkers; with beer drinkers the correlation was negative. The correlation with pulque is interesting, since pulque consumption is considered to be low scale in some rural areas. The negative correlation with beer may indicate that beer drinking is nor a good indicator of alcoholism. Results, though limited to the possibilities of an ecological study, reveal the necessity of effective actions in the regions where spirits and pulque are consumed in excess.
[Evaluating training programs on occupational health and safety: questionnaire development].
Zhou, Xiao-Yan; Wang, Zhi-Ming; Wang, Mian-Zhen
2006-03-01
To develop a questionnaire to evaluate the quality of training programs on occupational health and safety. A questionnaire comprising five subscales and 21 items was developed. The reliability and validity of the questionnaire was tested. Final validation of the questionnaire was undertaken in 700 workers in an oil refining company. The Cronbach's alpha coefficients of the five subscales ranged from 0.6194 to 0.6611. The subscale-scale Pearson correlation coefficients ranged from 0.568 to 0.834 . The theta coefficients of the five subscales were greater than 0.7. The factor loadings of the five subscales in the principal component analysis ranged from 0.731 to 0.855. Use of the questionnaire in the 700 workers produced a good discriminability, with excellent, good, fair and poor comprising 22.2%, 31.2%, 32.4% and 14.1 respectively. Given the fact that 18.7% of workers had never been trained and 29.7% of workers got one-off training only, the training program scored an average of 57.2. The questionnaire is suitable to be used in evaluating the quality of training programs on occupational health and safety. The oil refining company needs to improve training for their workers on occupational health and safety.
Optoelectronic properties and Seebeck coefficient in SnSe thin films
NASA Astrophysics Data System (ADS)
Urmila, K. S.; Namitha, T. A.; Rajani, J.; Philip, R. R.; Pradeep, B.
2016-09-01
SnSe thin films of thickness 180 nm have been deposited on glass substrates by reactive evaporation at an optimized substrate temperature of 523 ± 5 K and pressure of 10-5 mbar. The as-prepared SnSe thin films are characterized for their structural, optical and electrical properties by various experimental techniques. The p-type conductivity, near-optimum direct band gap, high absorption coefficient and good photosensitivity of the SnSe thin film indicate its suitability for photovoltaic applications. The optical constants, loss factor, quality factor and optical conductivity of the films are evaluated. The results of Hall and thermoelectric power measurements are correlated to determine the density of states, Fermi energy and effective mass of carriers and are obtained as 2.8 × 1017 cm-3, 0.03 eV and 0.05m 0 respectively. The high Seebeck coefficient ≈ 7863 μV/K, reasonably good power factor ≈ 7.2 × 10-4 W/(m·K2) and thermoelectric figure of merit ≈ 1.2 observed at 42 K suggests that, on further work, the prepared SnSe thin films can also be considered as a possible candidate for cryogenic thermoelectric applications.
Reliability and Validity of Wisconsin Upper Respiratory Symptom Survey, Korean Version
Yang, Su-Young; Kang, Weechang; Yeo, Yoon; Park, Yang-Chun
2011-01-01
Background The Wisconsin Upper Respiratory Symptom Survey (WURSS) is a self-administered questionnaire developed in the United States to evaluate the severity of the common cold and its reliability has been validated. We developed a Korean language version of this questionnaire by using a sequential forward and backward translation approach. The purpose of this study was to validate the Korean version of the Wisconsin Upper Respiratory Symptom Survey (WURSS-K) in Korean patients with common cold. Methods This multicenter prospective study enrolled 107 participants who were diagnosed with common cold and consented to participate in the study. The WURSS-K includes 1 global illness severity item, 32 symptom-based items, 10 functional quality-of-life (QOL) items, and 1 item assessing global change. The SF-8 was used as an external comparator. Results The participants were 54 women and 53 men aged 18 to 42 years. The WURSS-K showed good reliability in 10 domains, with Cronbach’s alphas ranging from 0.67 to 0.96 (mean: 0.84). Comparison of the reliability coefficients of the WURSS-K and WURSS yielded a Pearson correlation coefficient of 0.71 (P = 0.02). Validity of the WURSS-K was evaluated by comparing it with the SF-8, which yielded a Pearson correlation coefficient of −0.267 (P < 0.001). The Guyatt’s responsiveness index of the WURSS-K ranged from 0.13 to 0.46, and the correlation coefficient with the WURSS was 0.534 (P < 0.001), indicating that there was close correlation between the WURSS-K and WURSS. Conclusions The WURSS-K is a reliable, valid, and responsive disease-specific questionnaire for assessing symptoms and QOL in Korean patients with common cold. PMID:21691034
Central Corneal Thickness Reproducibility among Ten Different Instruments.
Pierro, Luisa; Iuliano, Lorenzo; Gagliardi, Marco; Ambrosi, Alessandro; Rama, Paolo; Bandello, Francesco
2016-11-01
To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852-0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon-Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss-RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device.
Simplified Radiographic Damage Index for Affected Joints in Chronic Gouty Arthritis
2016-01-01
The aim of this study was to develop and validate a new radiographic damage scoring method (DAmagE index of GoUt; DAEGU) in chronic gout using plain radiography. Two independent observers scored foot x-rays from 15 patients with chronic gout according to the DAEGU method and the modified Sharp/van der Heijde (SvdH) method. The 10 metatarsophalangeal (MTP) and 2 interphalangeal (IP) joints of the first toes of both feet were scored to assess the degrees of erosion and joint space narrowing (JSN). The intraobserver and interobserver reliabilities were analyzed by calculating the intraclass correlation coefficient (ICC) and minimal detectable change (MDC). The correlation between the DAEGU and SvdH methods was analyzed by calculating the Spearman's rho correlation coefficients and Kappa coefficients. The DAEGU method was found to be highly reproducible (0.945–0.987 for the intraobserver and 0.993–0.996 for the interobserver ICC values). The erosion, JSN, and total scores exhibited strong positive correlations between the DAEGU and SvdH methods and also within each method (r = 0.860–0.969, P < 0.001 for all parameters). The DAEGU and SvdH methods were in very good agreement as determined by Kappa coefficient analysis [0.732 (0.387–1.000) for erosion and 1.000 (1.000–1.000) for JSN]. In conclusion, this study revealed that DAEGU method was a reliable and feasible tool in the assessment of radiographic damage in chronic gout. The DAEGU method may provide a more easy assessment of structural damage in chronic gout in the real clinical practice. PMID:26955246
Cheung, Kenneth M C; Senkoylu, Alpaslan; Alanay, Ahmet; Genc, Yasemin; Lau, Sarah; Luk, Keith D
2007-05-01
Validation study to define validity and reliability of an adapted and translated questionnaire. Assessment of the concurrent validity and reliability of a Chinese version of SRS-22 outcome instrument. No valid health-related quality of life (HRQL) outcome instrument exists for patients with spinal deformity in Chinese. The modified SRS-22 questionnaire was proven to be an appropriate outcome instrument in English, and has already been translated and validated in several other languages. The English version of the SRS-22 questionnaire was adapted to Chinese according to the International Quality of Life Assessment Project guidelines. To assess reliability, 48 subjects with adolescent idiopathic scoliosis (mean age, 16.5 years) filled the questionnaire on 2 separate occasions (Group 1). To assess concurrent validity, 50 subjects (mean age, 21 years) filled in the same questionnaire and a previously validated Chinese version of the Short Form-36 (SF36) questionnaire (Group 2). Internal consistency, reproducibility and concurrent validity were determined with Cronbach's alpha coefficient, interclass correlation coefficient and Pearson correlation coefficient, respectively. Cronbach's alpha coefficient for the 4 major domains (function/activity, pain, self-image/appearance and mental health) were high. Intraclass correlation was also excellent for all domains. For concurrent validity, excellent correlation was found in 1 domain, good in 12 domains, moderate in 3 domains, and poor in 1 domain of the 17 relevant domains. Both cultural adaptation and linguistic translation are essential in any attempt to use a HRQL questionnaire across cultures. The Chinese version of the SRS-22 outcome instrument has satisfactory internal consistency and excellent reproducibility. It is ready for use in clinical studies on idiopathic scoliosis in Chinese-speaking societies.
Revealing how network structure affects accuracy of link prediction
NASA Astrophysics Data System (ADS)
Yang, Jin-Xuan; Zhang, Xiao-Dong
2017-08-01
Link prediction plays an important role in network reconstruction and network evolution. The network structure affects the accuracy of link prediction, which is an interesting problem. In this paper we use common neighbors and the Gini coefficient to reveal the relation between them, which can provide a good reference for the choice of a suitable link prediction algorithm according to the network structure. Moreover, the statistical analysis reveals correlation between the common neighbors index, Gini coefficient index and other indices to describe the network structure, such as Laplacian eigenvalues, clustering coefficient, degree heterogeneity, and assortativity of network. Furthermore, a new method to predict missing links is proposed. The experimental results show that the proposed algorithm yields better prediction accuracy and robustness to the network structure than existing currently used methods for a variety of real-world networks.
Developing a Model for Forecasting Road Traffic Accident (RTA) Fatalities in Yemen
NASA Astrophysics Data System (ADS)
Karim, Fareed M. A.; Abdo Saleh, Ali; Taijoobux, Aref; Ševrović, Marko
2017-12-01
The aim of this paper is to develop a model for forecasting RTA fatalities in Yemen. The yearly fatalities was modeled as the dependent variable, while the number of independent variables included the population, number of vehicles, GNP, GDP and Real GDP per capita. It was determined that all these variables are highly correlated with the correlation coefficient (r ≈ 0.9); in order to avoid multicollinearity in the model, a single variable with the highest r value was selected (real GDP per capita). A simple regression model was developed; the model was very good (R2=0.916); however, the residuals were serially correlated. The Prais-Winsten procedure was used to overcome this violation of the regression assumption. The data for a 20-year period from 1991-2010 were analyzed to build the model; the model was validated by using data for the years 2011-2013; the historical fit for the period 1991 - 2011 was very good. Also, the validation for 2011-2013 proved accurate.
Patjanasoontornm, Niramol; Wongniyom, Kusalapom; Pradubwong, Suteera; Piyavhakul, Navanant; Chowchuen, Bowornsilp
2014-10-01
To examine levels of self-esteem of adolescents with repaired cleft lip and cleft palate at Khon Kaen University Cleft Center and its correlation with nasolabial appearance. Across-sectional survey of 93 adolescents with repaired cleft lip and palate. A total nasolabial appearance score was 2.8 +/- 0.36 (fair to good). The mean of the total self-esteem score for all respondents was 20.11 +/- 3.27 (maximum 30). There was no-significant correlation between nasolabial appearance and self esteem (Pearson product-moment correlation coefficiency (r) = 0.18, p = 0.08. The self-esteem scores of good, fair and poor appearance were 20.5 +/- 0.98, 19.8 +/- 0.32, 19 +/- 2.09 respectively. The nasolabial appearance of repaired cleft lip and palate not be the only factor but other psychosocialfactors also may play a role in their self-esteem. The analysis of this study found no relationship between self-esteem and appearance.
A meta-analysis of the validity of FFQ targeted to adolescents.
Tabacchi, Garden; Filippi, Anna Rita; Amodio, Emanuele; Jemni, Monèm; Bianco, Antonino; Firenze, Alberto; Mammina, Caterina
2016-05-01
The present work is aimed at meta-analysing validity studies of FFQ for adolescents, to investigate their overall accuracy and variables that can affect it negatively. A meta-analysis of sixteen original articles was performed within the ASSO Project (Adolescents and Surveillance System in the Obesity prevention). The articles assessed the validity of FFQ for adolescents, compared with food records or 24 h recalls, with regard to energy and nutrient intakes. Pearson's or Spearman's correlation coefficients, means/standard deviations, kappa agreement, percentiles and mean differences/limits of agreement (Bland-Altman method) were extracted. Pooled estimates were calculated and heterogeneity tested for correlation coefficients and means/standard deviations. A subgroup analysis assessed variables influencing FFQ accuracy. An overall fair/high correlation between FFQ and reference method was found; a good agreement, measured through the intake mean comparison for all nutrients except sugar, carotene and K, was observed. Kappa values showed fair/moderate agreement; an overall good ability to rank adolescents according to energy and nutrient intakes was evidenced by data of percentiles; absolute validity was not confirmed by mean differences/limits of agreement. Interviewer administration mode, consumption interval of the previous year/6 months and high number of food items are major contributors to heterogeneity and thus can reduce FFQ accuracy. The meta-analysis shows that FFQ are accurate tools for collecting data and could be used for ranking adolescents in terms of energy and nutrient intakes. It suggests how the design and the validation of a new FFQ should be addressed.
An Ultra-high Resolution Synthetic Precipitation Data for Ungauged Sites
NASA Astrophysics Data System (ADS)
Kim, Hong-Joong; Choi, Kyung-Min; Oh, Jai-Ho
2018-05-01
Despite the enormous damage caused by record heavy rainfall, the amount of precipitation in areas without observation points cannot be known precisely. One way to overcome these difficulties is to estimate meteorological data at ungauged sites. In this study, we have used observation data over Seoul city to calculate high-resolution (250-meter resolution) synthetic precipitation over a 10-year (2005-2014) period. Furthermore, three cases are analyzed by evaluating the rainfall intensity and performing statistical analysis over the 10-year period. In the case where the typhoon "Meari" passed to the west coast during 28-30 June 2011, the Pearson correlation coefficient was 0.93 for seven validation points, which implies that the temporal correlation between the observed precipitation and synthetic precipitation was very good. It can be confirmed that the time series of observation and synthetic precipitation in the period almost completely matches the observed rainfall. On June 28-29, 2011, the estimation of 10 to 30 mm h-1 of continuous strong precipitation was correct. In addition, it is shown that the synthetic precipitation closely follows the observed precipitation for all three cases. Statistical analysis of 10 years of data reveals a very high correlation coefficient between synthetic precipitation and observed rainfall (0.86). Thus, synthetic precipitation data show good agreement with the observations. Therefore, the 250-m resolution synthetic precipitation amount calculated in this study is useful as basic data in weather applications, such as urban flood detection.
Liu, Yuan; Chen, Wei-Hua; Hou, Qiao-Juan; Wang, Xi-Chang; Dong, Ruo-Yan; Wu, Hao
2014-04-01
Near infrared spectroscopy (NIR) was used in this experiment to evaluate the freshness of ice-stored large yellow croaker (Pseudosciaena crocea) during different storage periods. And the TVB-N was used as an index to evaluate the freshness. Through comparing the correlation coefficent and standard deviations of calibration set and validation set of models established by singly and combined using of different pretreatment methods, different modeling methods and different wavelength region, the best TVB-N models of ice-stored large yellow croaker sold in the market were established to predict the freshness quickly. According to the research, the model shows that the best performance could be established by using the normalization by closure (Ncl) with 1st derivative (Dbl) and normalization to unit length (Nle) with 1st derivative as the pretreated method and partial least square (PLS) as the modeling method combined with choosing the wavelength region of 5 000-7 144, and 7 404-10 000 cm(-1). The calibration model gave the correlation coefficient of 0.992, with a standard error of calibration of 1.045 and the validation model gave the correlation coefficient of 0.999, with a standard error of prediction of 0.990. This experiment attempted to combine several pretreatment methods and choose the best wavelength region, which has got a good result. It could have a good prospective application of freshness detection and quality evaluation of large yellow croaker in the market.
Assessment of the accuracy of a new tool for the screening of smartphone addiction
2017-01-01
Objective To translate, adapt and validate the Smartphone Addiction Inventory (SPAI) in a Brazilian population of young adults. Method We employed the translation and back-translation method for the adaptation of the Brazilian version SPAI (SPAI-BR). The sample consisted of 415 university students. Data was collected through an electronic questionnaire, which consisted of the SPAI-BR and the Goodman Criteria (gold standard). The retests were carried out 10–15 days after the initial tests with 130 individuals. Results The SPAI-BR maintained semantic, idiomatic and conceptual equivalences from the original scale. The Confirmatory Factor Analysis confirmed the One-factor model of the SPAI with good fit indexes (x2 = 767.861, CFI = 0.913, TLI = 0.905, RMSE = 0.061, WRMR = 1.465). The Kuder-Richardson Coefficient showed good internal consistency. The analysis of the ROC curve established an area under the curve of 86.38%. The Intraclass-Correlation Coefficient of 0.926 between the test and the retest demonstrated an excellent temporal stability. The high correlation between SPAI-BR and the Goodman Criteria (rs = 0.750) established the convergent validity. Conclusion The SPAI-BR is a valid and reliable tool for the detection of Smartphone Addiction in Brazilian university students. PMID:28520798
Estimating leaf nitrogen accumulation in maize based on canopy hyperspectrum data
NASA Astrophysics Data System (ADS)
Gu, Xiaohe; Wang, Lizhi; Song, Xiaoyu; Xu, Xingang
2016-10-01
Leaf nitrogen accumulation (LNA) has important influence on the formation of crop yield and grain protein. Monitoring leaf nitrogen accumulation of crop canopy quantitively and real-timely is helpful for mastering crop nutrition status, diagnosing group growth and managing fertilization precisely. The study aimed to develop a universal method to monitor LNA of maize by hyperspectrum data, which could provide mechanism support for mapping LNA of maize at county scale. The correlations between LNA and hyperspectrum reflectivity and its mathematical transformations were analyzed. Then the feature bands and its transformations were screened to develop the optimal model of estimating LNA based on multiple linear regression method. The in-situ samples were used to evaluate the accuracy of the estimating model. Results showed that the estimating model with one differential logarithmic transformation (lgP') of reflectivity could reach highest correlation coefficient (0.889) with lowest RMSE (0.646 g·m-2), which was considered as the optimal model for estimating LNA in maize. The determination coefficient (R2) of testing samples was 0.831, while the RMSE was 1.901 g·m-2. It indicated that the one differential logarithmic transformation of hyperspectrum had good response with LNA of maize. Based on this transformation, the optimal estimating model of LNA could reach good accuracy with high stability.
Roque, Fátima; Soares, Sara; Breitenfeld, Luiza; Gonzalez-Gonzalez, Cristian; Figueiras, Adolfo; Herdeiro, Maria Teresa
2014-01-01
To develop and evaluate the reliability of a self-administered questionnaire designed to assess the attitudes and knowledge of community pharmacists in Portugal about microbial resistance and the antibiotic dispensing process. This study was divided into the following three stages: (1) design of the questionnaire, which included a literature review and a qualitative study with focus-group sessions; (2) assessment of face and content validity, using a panel of experts and a pre-test of community pharmacists; and, (3) pilot study and reliability analysis, which included a test-retest study covering fifty practising pharmacists based at community pharmacies in five districts situated in Northern Portugal. Questionnaire reproducibility was quantified using the intraclass correlation coefficient (ICC; 95% confidence interval) computed by means of one-way analysis of variance (ANOVA). Internal consistency was evaluated using Cronbach's alpha. The correlation coefficients were fair to good (ICC>0.4) for all statements (scale-items) regarding knowledge of and attitudes to antibiotic resistance, and ranged from fair to good to excellent for statements about situations in which pharmacists acknowledged that antibiotics were sometimes dispensed without a medical prescription (ICC>0.8). Cronbach's alpha for this section was 0.716. The questionnaire designed in this study is valid and reliable in terms of content validity, face validity and reproducibility.
Hidaka, Nobuhiro; Murata, Masaharu; Sasahara, Jun; Ishii, Keisuke; Mitsuda, Nobuaki
2015-05-01
Observed/expected lung area to head circumference ratio (o/e LHR) and lung to thorax transverse area ratio (LTR) are the sonographic indicators of postnatal outcome in fetuses with congenital diaphragmatic hernia (CDH), and they are not influenced by gestational age. We aimed to evaluate the relationship between these two parameters in the same subjects with fetal left-sided CDH. Fetuses with left-sided CDH managed between 2005 and 2012 were included. Data of LTR and o/e LHR values measured on the same day prior to 33 weeks' gestation in target fetuses were retrospectively collected. The correlation between the two parameters was estimated using the Spearman's rank-correlation coefficient, and linear regression analysis was used to assess the relationship between them. Data on 61 measurements from 36 CDH fetuses were analyzed to obtain a Spearman's rank-correlation coefficient of 0.74 with the following linear equation: LTR = 0.002 × (o/e LHR) + 0.005. The determination coefficient of this linear equation was sufficiently high at 0.712, and the prediction accuracy obtained with this regression formula was considered satisfactory. A good linear correlation between the LTR and the o/e LHR was obtained, suggesting that we can translate the predictive parameters for each other. This information is expected to be useful to improve our understanding of different investigations focusing on LTR or o/e LHR as a predictor of postnatal outcome in CDH. © 2014 Japanese Teratology Society.
Huang, Jinhai; Liao, Na; Savini, Giacomo; Li, Yuanguang; Bao, Fangjun; Yu, Ye; Yu, Ayong; Wang, Qinmei
2015-02-01
To determine the repeatability and reproducibility of measurements of central corneal thickness (CCT) using optical low-coherence reflectometry (Lenstar LS900; Haag Streit) in normal eyes and post-femtosecond laser in situ keratomileusis (post-FS-LASIK) eyes and evaluate their agreement with ultrasound (US) pachymetry. CCT was measured using Lenstar and US pachymetry sequentially in normal and post-FS-LASIK eyes by 2 experienced observers. Intraoperator repeatability and interoperator reproducibility were assessed by within-subject standard deviation, test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient. Paired t-tests and Bland-Altman plots were used for analyzing agreement between the 2 devices. In this study, 55 healthy subjects and 50 post-FS-LASIK patients were recruited. Test-retest repeatability of Lenstar was within 10 μm, CoV was less than 1.0%, and intraclass correlation coefficient was more than 0.9 in both normal and post-FS-LASIK groups. Mean difference between these methods was 1.4 ± 4.2 μm and -1.7 ± 5.4 μm, respectively. Moreover, measurements of CCT showed narrow 95% limits of agreement (range, normal group: -6.8 and 9.6 μm; post-FS-LASIK group: -12.4 and 8.9 μm), which implied good agreement. Measurements of CCT using Lenstar showed excellent intraoperator repeatability and interoperator reproducibility both in normal eyes and post-FS-LASIK eyes. Measurements of CCT using Lenstar and US pachymetry showed good agreement and both can be used interchangeably.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demmel, F.; Mukhopadhyay, S.; Department of Materials, Imperial College London, Exhibition Road, London SW7 2AZ
2016-01-07
The ionic stochastic motions in the molten alkali halide NaF are investigated by quasielastic neutron scattering and first principles molecular dynamics simulation. Quasielastic neutron scattering was employed to extract the diffusion behavior of the sodium ions in the melt. An extensive first principles based simulation on a box of up to 512 particles has been performed to complement the experimental data. From that large box, a smaller 64-particle box has then been simulated over a runtime of 60 ps. A good agreement between calculated and neutron data on the level of spectral shape has been obtained. The obtained sodium diffusionmore » coefficients agree very well. The simulation predicts a fluorine diffusion coefficient similar to the sodium one. Applying the Nernst-Einstein equation, a remarkable large cross correlation between both ions can be deduced. The velocity cross correlations demonstrate a positive correlation between the ions over a period of 0.1 ps. That strong correlation is evidence that the unlike ions do not move completely statistically independent and have a strong association over a short period of time.« less
Doubova, Svetlana V; Aguirre-Hernandez, Rebeca; Infante-Castañeda, Claudia; Martinez-Vega, Ingrid; Pérez-Cuevas, Ricardo
2015-10-01
The purpose of this study was to validate the Mexican version of the Support Person Unmet Needs Survey (SPUNS-SFM). A cross-sectional survey that included 826 primary caregivers of cancer patients was conducted from June to December 2013 at the Oncology Hospital of the Mexican Institute of Social Security in Mexico City. The validation procedure comprised (1) content validity through a group of experts; (2) construct validity through an exploratory factor analysis based on the polychoric correlation matrix; (3) internal consistency using Cronbach's alpha; (4) convergent validity between SPUNS-SFM and quality of life, anxiety-and-depression scales by calculating Spearman's rank correlation coefficient;( 5) discriminative validity through the Wilcoxon rank-sum test; and (6) test-retest reliability using intraclass correlation coefficient. SPUNS-SFM has 23 items with six factors accounting for 65 % of the total variance. The domains were concerns about the future, access and continuity of healthcare, information, work and finance, and personal and emotional needs. Cronbach's alpha values ranged from 0.70 to 0.88 among factors. SPUNS-SFM had moderate convergent validity compared with quality of life and depression-and-anxiety scales and good discriminative validity, revealing high needs for younger caregivers and more emotional needs for caregivers of patients with advanced cancer stages. Intraclass correlation coefficient between SPUNS-SFM measurements was 0.78. SPUNS-SFM is a valid and reliable tool to identify needs of caregivers of cancer patients.
NASA Astrophysics Data System (ADS)
Lalneihpuii, R.; Shrivastava, Ruchi; Mishra, Raj Kumar
2018-05-01
Using statistical mechanical model with square-well (SW) interatomic potential within the frame work of mean spherical approximation, we determine the composition dependent microscopic correlation functions, interdiffusion coefficients, surface tension and chemical ordering in Ag-Cu melts. Further Dzugutov universal scaling law of normalized diffusion is verified with SW potential in binary mixtures. We find that the excess entropy scaling law is valid for SW binary melts. The partial and total structure factors in the attractive and repulsive regions of the interacting potential are evaluated and then Fourier transformed to get partial and total radial distribution functions. A good agreement between theoretical and experimental values for total structure factor and the reduced radial distribution function are observed, which consolidates our model calculations. The well-known Bhatia-Thornton correlation functions are also computed for Ag-Cu melts. The concentration-concentration correlations in the long wavelength limit in liquid Ag-Cu alloys have been analytically derived through the long wavelength limit of partial correlation functions and apply it to demonstrate the chemical ordering and interdiffusion coefficients in binary liquid alloys. We also investigate the concentration dependent viscosity coefficients and surface tension using the computed diffusion data in these alloys. Our computed results for structure, transport and surface properties of liquid Ag-Cu alloys obtained with square-well interatomic interaction are fully consistent with their corresponding experimental values.
NASA Astrophysics Data System (ADS)
Zhang, Qian-Ming; Shang, Ming-Sheng; Zeng, Wei; Chen, Yong; Lü, Linyuan
2010-08-01
Collaborative filtering is one of the most successful recommendation techniques, which can effectively predict the possible future likes of users based on their past preferences. The key problem of this method is how to define the similarity between users. A standard approach is using the correlation between the ratings that two users give to a set of objects, such as Cosine index and Pearson correlation coefficient. However, the costs of computing this kind of indices are relatively high, and thus it is impossible to be applied in the huge-size systems. To solve this problem, in this paper, we introduce six local-structure-based similarity indices and compare their performances with the above two benchmark indices. Experimental results on two data sets demonstrate that the structure-based similarity indices overall outperform the Pearson correlation coefficient. When the data is dense, the structure-based indices can perform competitively good as Cosine index, while with lower computational complexity. Furthermore, when the data is sparse, the structure-based indices give even better results than Cosine index.
NASA Astrophysics Data System (ADS)
Torkamani, Shahab; Roy, Samit; Barkey, Mark E.; Sazonov, Edward; Burkett, Susan; Kotru, Sushma
2014-09-01
In the current investigation, an innovative time-domain damage index is introduced for the first time which is based on local statistical features of the waveform. This damage index is called the ‘normalized correlation moment’ (NCM) and is composed of the nth moment of the cross-correlation of the baseline and comparison waves. The performance of this novel damage index is compared for some synthetic signals with that of an existing damage index based on the Pearson correlation coefficient (signal difference coefficient, SDC). The proposed damage index is shown to have significant advantages over the SDC, including sensitivity to the attenuation of the signal and lower sensitivity to the signal’s noise level. Numerical simulations using Abaqus finite element (FE) software show that this novel damage index is not only capable of detecting the delamination type of damage, but also exhibits a good ability in the assessment of this type of damage in laminated composite structures. The NCM damage index is also validated using experimental data for identification of delamination in composites.
Rating scale for psychogenic nonepileptic seizures: scale development and clinimetric testing.
Cianci, Vittoria; Ferlazzo, Edoardo; Condino, Francesca; Mauvais, Hélène Somma; Farnarier, Guy; Labate, Angelo; Latella, Maria Adele; Gasparini, Sara; Branca, Damiano; Pucci, Franco; Vazzana, Francesco; Gambardella, Antonio; Aguglia, Umberto
2011-06-01
Our aim was to develop a clinimetric scale evaluating motor phenomena, associated features, and severity of psychogenic nonepileptic seizures (PNES). Sixty video/EEG-recorded PNES induced by suggestion maneuvers were evaluated. We examined the relationship between results from this scale and results from the Clinical Global Impression (CGI) scale to validate this technique. Interrater reliabilities of the PNES scale for three raters were analyzed using the AC1 statistic, Kendall's coefficient of concordance (KCC), and intraclass correlation coefficients (ICCs). The relationship between the CGI and PNES scales was evaluated with Spearman correlations. The AC1 statistic demonstrated good interrater reliability for each phenomenon analyzed (tremor/oscillation, tonic; clonic/jerking, hypermotor/agitation, atonic/akinetic, automatisms, associated features). KCC and the ICC showed moderate interrater agreement for phenomenology, associated phenomena, and total PNES scores. Spearman's correlation of mean CGI score with mean total PNES score was 0.69 (P<0.001). The scale described here accurately evaluates the phenomenology of PNES and could be used to assess and compare subgroups of patients with PNES. Copyright © 2011 Elsevier Inc. All rights reserved.
Nazhan, Salam; Ghassemlooy, Zabih; Busawon, Krishna
2016-01-01
In this paper, the influence of the rotating polarization-preserved optical feedback on the chaos synchronization of a vertical-cavity surface-emitting laser (VCSEL) is investigated experimentally. Two VCSELs' polarization modes (XP) and (YP) are gradually rotated and re-injected back into the VCSEL. The anti-phase dynamics synchronization of the two polarization modes is evaluated using the cross-correlation function. For a fixed optical feedback, a clear relationship is found between the cross-correlation coefficient and the polarization angle θp. It is shown that high-quality anti-phase polarization-resolved chaos synchronization is achieved at higher values of θp. The maximum value of the cross-correlation coefficient achieved is -0.99 with a zero time delay over a wide range of θp beyond 65° with a poor synchronization dynamic at θp less than 65°. Furthermore, it is observed that the antiphase irregular oscillation of the XP and YP modes changes with θp. VCSEL under the rotating polarization optical feedback can be a good candidate as a chaotic synchronization source for a secure communication system.
Formulas for the elastic constants of plates with integral waffle-like stiffening
NASA Technical Reports Server (NTRS)
Dow, Norris R; Libove, Charles; Hubka, Ralph E
1954-01-01
Formulas are derived for the fifteen elastic constants associated with bending, stretching, twisting, and shearing of plates with closely spaced integral ribbing in a variety of configurations and proportions. In the derivation the plates are considered, conceptually, as more uniform orthotropic plates somewhat on the order of plywood. The constants, which include the effectiveness of the ribs for resisting deformations other than bending and stretching in their longitudinal directions, are defined in terms of four coefficients, and theoretical and experimental methods for the evaluation of these coefficients are discussed. Four of the more important elastic constants are predicted by these formulas and are compared with test results. Good correlation is obtained. (author)
Block-based scalable wavelet image codec
NASA Astrophysics Data System (ADS)
Bao, Yiliang; Kuo, C.-C. Jay
1999-10-01
This paper presents a high performance block-based wavelet image coder which is designed to be of very low implementational complexity yet with rich features. In this image coder, the Dual-Sliding Wavelet Transform (DSWT) is first applied to image data to generate wavelet coefficients in fixed-size blocks. Here, a block only consists of wavelet coefficients from a single subband. The coefficient blocks are directly coded with the Low Complexity Binary Description (LCBiD) coefficient coding algorithm. Each block is encoded using binary context-based bitplane coding. No parent-child correlation is exploited in the coding process. There is also no intermediate buffering needed in between DSWT and LCBiD. The compressed bit stream generated by the proposed coder is both SNR and resolution scalable, as well as highly resilient to transmission errors. Both DSWT and LCBiD process the data in blocks whose size is independent of the size of the original image. This gives more flexibility in the implementation. The codec has a very good coding performance even the block size is (16,16).
Modeling cesium ion exchange on fixed-bed columns of crystalline silicotitanate granules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Latheef, I.M.; Huckman, M.E.; Anthony, R.G.
2000-05-01
A mathematical model is presented to simulate Cs exchange in fixed-bed columns of a novel crystalline silicotitanate (CST) material, UOP IONSIV IE-911. A local equilibrium is assumed between the macropores and the solid crystals for the particle material balance. Axial dispersed flow and film mass-transfer resistance are incorporated into the column model. Cs equilibrium isotherms and diffusion coefficients were measured experimentally, and dispersion and film mass-transfer coefficients were estimated from correlations. Cs exchange column experiments were conducted in 5--5.7 M Na solutions and simulated using the proposed model. Best-fit diffusion coefficients from column simulations were compared with previously reported batchmore » values of Gu et al. and Huckman. Cs diffusion coefficients for the column were between 2.5 and 5.0 x 10{sup {minus}11} m{sup 2}/s for 5--5.7 M Na solutions. The effect of the isotherm shape on the Cs diffusion coefficient was investigated. The proposed model provides good fits to experimental data and may be utilized in designing commercial-scale units.« less
Krzek, Jan; Piotrowska, Joanna
2011-01-01
A fast spectrophotometric method has been developed for bacitracin identification and determination after condensation reaction with dabsyl chloride. In addition, determination of dye stability of sulfonamide derivative and identification of the molar ratio of reagents was done at various time-points. The developed method has a good linearity with very broad spectrum, correlation coefficient of r = 0.9972, good precision (RSD = 1.54 +/- 0.11%), and recovery at three different levels of concentration was found between 98.33% and 103.47%. Usefulness of the method was demonstrated by positive results obtained during determination of bacitracin concentration in bulk drug.
Vespa, Anna; Giulietti, Maria Velia; Spatuzzi, Roberta; Fabbietti, Paolo; Meloni, Cristina; Gattafoni, Pisana; Ottaviani, Marica
2017-06-01
This study aimed at assessing the reliability and construct validity of Brief Multidimensional Measure of Religiousness/Spirituality (BMMRS) on Italian sample. 353 Italian participants: 58.9% affected by different diseases and 41.1% healthy subjects. The results of descriptive statistics of internal consistency reliabilities (Chronbach's coefficient) of the BMMRS revealed a remarkable consistency and reliability of different scales DSE, SpC, SC, CSC, VB, SPY-WELL and a good Inter-Class Correlations ≥70 maintaining a good stability of the measures over the time. BMMRS is a useful inventory for the evaluation of the principal spiritual dimensions.
Kakite, Suguru; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Facciuto, Marcelo; Donnerhack, Claudia; Taouli, Bachir
2015-01-01
To evaluate short-term test-retest and interobserver reproducibility of IVIM (intravoxel incoherent motion) diffusion parameters and ADC (apparent diffusion coefficient) of hepatocellular carcinoma (HCC) and liver parenchyma at 3.0T. In this prospective Institutional Review Board (IRB)-approved study, 11 patients were scanned twice using a free-breathing single-shot echo-planar-imaging, diffusion-weighted imaging (DWI) sequence using 4 b values (b = 0, 50, 500, 1000 s/mm(2)) and IVIM DWI using 16 b values (0-800 s/mm(2)) at 3.0T. IVIM parameters (D: true diffusion coefficient, D*: pseudodiffusion coefficient, PF: perfusion fraction) and ADC (using 4 b and 16 b) were calculated. Short-term test-retest and interobserver reproducibility of IVIM parameters and ADC were assessed by measuring correlation coefficient, coefficient of variation (CV), and Bland-Altman limits of agreements (BA-LA). Fifteen HCCs were assessed in 10 patients. Reproducibility of IVIM metrics in HCC was poor for D* and PF (mean CV 60.6% and 37.3%, BA-LA: -161.6% to 135.3% and -66.2% to 101.0%, for D* and PF, respectively), good for D and ADC (CV 19.7% and <16%, BA-LA -57.4% to 36.3% and -38.2 to 34.1%, for D and ADC, respectively). Interobserver reproducibility was on the same order of test-retest reproducibility except for PF in HCC. Reproducibility of diffusion parameters was better in liver parenchyma compared to HCC. Poor reproducibility of D*/PF and good reproducibility for D/ADC were observed in HCC and liver parenchyma. These findings may have implications for trials using DWI in HCC. © 2014 Wiley Periodicals, Inc.
de Cremoux, P; Bieche, I; Tran-Perennou, C; Vignaud, S; Boudou, E; Asselain, B; Lidereau, R; Magdelénat, H; Becette, V; Sigal-Zafrani, B; Spyratos, F
2004-09-01
Quantitative reverse transcription-polymerase chain reaction (RT-PCR) used to detect minor changes in specific mRNA concentrations may be associated with poor reproducibility. Stringent quality control is therefore essential at each step of the protocol, including the PCR procedure. We performed inter-laboratory quality control of quantitative PCR between two independent laboratories, using in-house RT-PCR assays on a series of hormone-related target genes in a retrospective consecutive series of 79 breast tumors. Total RNA was reverse transcribed in a single center. Calibration curves were performed for five target genes (estrogen receptor (ER)alpha, ERbeta, progesterone receptor (PR), CYP19 (aromatase) and Ki 67) and for two reference genes (human acidic ribosomal phosphoprotein PO (RPLPO) and TATA box-binding protein (TBP)). Amplification efficiencies of the calibrator were determined for each run and used to calculate mRNA expression. Correlation coefficients were evaluated for each target and each reference gene. A good correlation was observed for all target and reference genes in both centers using their own protocols and kits (P < 0.0001). The correlation coefficients ranged from 0.90 to 0.98 for the various target genes in the two centers. A good correlation was observed between the level of expression of the ERalpha and the PR transcripts (P < 0.001). A weak inverse correlation was observed in both centers between ERalpha and ERbeta levels, but only when TBP was the reference gene. No other correlation was observed with other parameters. Real-time PCR assays allow convenient quantification of target mRNA transcripts and quantification of target-derived nucleic acids in clinical specimens. This study addresses the importance of inter-laboratory quality controls for the use of a panel of real-time PCR assays devoted to clinical samples and protocols and to ensure their appropriate accuracy. This can also facilitate exchanges and multicenter comparison of data.
Trathitiphan, Warayos; Paholpak, Permsak; Sirichativapee, Winai; Wisanuyotin, Taweechok; Laupattarakasem, Pat; Sukhonthamarn, Kamolsak; Jeeravipoolvarn, Polasak; Kosuwon, Weerachai
2016-10-01
HOOS was developed as an extension of the Western Ontario and McMaster Universities' Osteoarthritis Index questionnaire for measuring symptoms and functional limitations related to the hip(s) of patients with osteoarthritis. To determine the validity and reliability of the Thai version of the Hip disability and Osteoarthritis Outcome Score (HOOS) vis-à-vis hip osteoarthritis, the original HOOS was translated into a Thai version of HOOS, according to international recommendations. Patients with hip osteoarthritis (n = 57; 25 males) were asked to complete the Thai version of HOOS twice: once then again after a 3-week interval. The test-retest reliability was analyzed using the intraclass correlation coefficient (ICC). Internal consistencies were analyzed using Cronbach's alpha, while the construct validity was tested by comparing the Thai HOOS with the Thai modified SF-36 and calculating the Spearman's rank correlation coefficients. The Thai HOOS produced good reliability (i.e., the ICC was greater than 0.9 in all five subscales). All of the Cronbach's alpha showed that the Thai HOOS had high internal consistency (Cronbach's alpha greater than 0.8), especially for the pain and ADL subscales (0.89 and 0.90, respectively). The Spearman's rank correlation for all five subscales of the Thai HOOS had moderate correlation with the Bodily Pain subscale of the Thai SF-36. The pain subscale of the Thai HOOS had a high correlation with the Vitality and Social Function subscales of the Thai SF-36 (r = 0.55 and 0.54)-with which the symptom subscale had a moderate correlation. The Thai version of HOOS had excellent internal consistency, excellent test-retest reliability, and good construct validity. It can be used as a reliable tool for assessing quality of life for patients with hip osteoarthritis in Thailand.
Li, Fengxia; Schnelle-Kreis, Jürgen; Cyrys, Josef; Wolf, Kathrin; Karg, Erwin; Gu, Jianwei; Orasche, Jürgen; Abbaszade, Gülcin; Peters, Annette; Zimmermann, Ralf
2018-08-01
to study the sources contributing to quasi-ultrafine particle (UFP) organic carbon and the spatial temporal variability of the sources. 24h quasi-UFP (particulate matter <0.36μm in this study) was sampled at a reference site continuously and at one of 5 other sites (T1, T2, T3, T4 and B1) in parallel in Augsburg, Germany from April 11th, 2014 to February 22nd, 2015, attempting to conduct 2-week campaigns at each site in 3 different seasons. Positive matrix factorization (PMF) was applied to measured organic tracers for source apportionment analyses. Pearson correlation coefficient r and coefficient of divergence (COD) were calculated to investigate spatial temporal variation of source contributions. 5 sources were identified comprising biomass burning (BB), traffic emissions (Traffic), biogenic secondary organic aerosol (bioSOA), isoprene originated secondary organic aerosol (isoSOA) and biomass burning related secondary organic aerosol (bbSOA). In general, good temporal correlation and uniform distribution within the study area are found for bioSOA and bbSOA, probably resulting from regional formation/transport. Lower temporal correlation and spatial heterogeneity of isoSOA were found at the city background site with local influence from green space and less traffic impact. BB demonstrated very good temporal correlation, but higher contributions at sites influenced by local residential heating emissions were observed. Traffic showed the least seasonality and lower correlation over time among the sources. However, it demonstrated low spatial heterogeneity of absolute contribution, and only a few days of elevated contribution was found at T3 when wind came directly from the street nearby. temporal correlation and spatial variability of sources contributing to the organic fraction of quasi-UFP vary among sites and source types and show source-specific characteristics. Therefore, caution should be taken when using one monitor site measurement to assess human exposure in health effect studies of quasi-UFP. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, J H; Peng, R; Du, Y; Mou, Y; Li, N N; Cheng, L
2016-11-08
Objective: To evaluate the reliability and validity of Parkinson's disease sleep scale-Chinese version (CPDSS) through a study of a large PD population in southwest China, and to explore the prevalence and characteristics of sleep disorders in Parkinson's disease (PD) patients from southwest China. Methods: A total of 544 PD patients and 220 control subjects were enrolled in our study. Demographic data, CPDSS, ESS, PDQ39, HAMD and H-Y stage were assessed in all subjects. Statistical description, Cronbach's alpha coefficient, intra-class correlation coefficient ( ICC ), Spearman rank correlation coefficient and Mann-Whitney U test were used for statistical analyses. Result: The Cronbach's alpha coefficient for CPDSS was 0.79, ICC of the total scale was 0.94 and ICC of each item ranged from 0.73 to 0.97. The factor analysis yielded a five-factor solution, which explained 63.4% of the total variance. Total and each item scores of CPDSS in PD patients were lower than those in healthy controls. 69.3% of PD patients had sleep disorder, while prevalence in the control group was only 29.6%. Negative correlation was found between CPDSS and ESS. Daytime sleepiness was the most common factor (35.9%) leading to sleep disorders. The sleep disorders of PD patients in Southwest China were significantly related with the course of disease, the severity of disease, the quality of life, depression, cognitive level and motor symptoms. Conclusion: CPDSS has good feasibility, reliability and validity in PD population from southwest China. CPDSS is considered as an effective tool for the assessment of sleep disorder in PD patients.
Stability and reproducibility of proteomic profiles measured with an aptamer-based platform.
Kim, Claire H; Tworoger, Shelley S; Stampfer, Meir J; Dillon, Simon T; Gu, Xuesong; Sawyer, Sherilyn J; Chan, Andrew T; Libermann, Towia A; Eliassen, A Heather
2018-05-30
The feasibility of SOMAscan, a multiplex, high sensitivity proteomics platform, for use in studies using archived plasma samples has not yet been assessed. We quantified 1,305 proteins from plasma samples donated by 16 Nurses' Health Study (NHS) participants, 40 NHSII participants, and 12 local volunteers. We assessed assay reproducibility using coefficients of variation (CV) from duplicate samples and intra-class correlation coefficients (ICC) and Spearman correlation coefficients (r) of samples processed (i.e., centrifuged and aliquoted into separate components) immediately, 24, and 48 hours after collection, as well as those of samples collected from the same individuals 1 year apart. CVs were <20% for 99% of proteins overall and <10% for 92% of proteins in heparin samples compared to 66% for EDTA samples. We observed ICC or Spearman r (comparing immediate vs. 24-hour delayed processing) ≥0.75 for 61% of proteins, with some variation by anticoagulant (56% for heparin and 70% for EDTA) and protein class (ranging from 49% among kinases to 83% among hormones). Within-person stability over 1 year was good (ICC or Spearman r ≥ 0.4) for 91% of proteins. These results demonstrate the feasibility of SOMAscan for analyses of archived plasma samples.
Reliability and validity of a questionnaire for self-assessment of complete dentures.
Komagamine, Yuriko; Kanazawa, Manabu; Kaiba, Yoshinori; Sato, Yusuke; Minakuchi, Shunsuke
2014-05-02
Demand for complete denture treatment is expected to rise over several decades. However, to date, no questionnaire on complete dentures, as evaluated by edentulous patients, has been shown to be reliable and valid. This study sought to assess the reliability and validity of Patient's Denture Assessment (PDA), which provides a multidimensional evaluation of dentures among edentulous patients. Patients, who had new complete dentures fabricated at the University Hospital of Dentistry, Tokyo Medical and Dental University through 2009 to 2010, were enrolled. The reliability of the PDA was determined by examining internal consistency and test-retest reliability. Internal consistency for all of the question items and the six subscales was measured using Cronbach's α and average inter-item correlation coefficients among 93 participants. For 33 of these participants, test-retest reliability was determined at a 2 month-interval using the interclass correlation coefficients (ICCs) and 95% confidence interval for the summary scores and the six subscale scores. The PDA was validated in 93 participants by examining the difference in the summary score and the six subscale scores of the PDA before and after replacement with new dentures by the paired t-test. Ability to detect change was also tested in 93 patients using effect size. The Cronbach's α for the PDA ranged from 0.56 to 0.93. The average inter-item correlation coefficients ranged from 0.28 to 0.83. ICCs for the PDA ranged from 0.37 to 0.83. The paired t-test showed a significant difference between the summary score and the six subscale scores before and after replacement with new dentures (p < 0.05) and the effect size was 0.97. The PDA demonstrated good reliability by assessing internal consistency and test-retest reliability. In addition, the PDA demonstrated good validity by assessing discriminant validity. Thus, the PDA could help dentists obtain a detailed understanding of the patients' perceptions in using their dentures.
Wan, Chonghua; Li, Hezhan; Fan, Xuejin; Yang, Ruixue; Pan, Jiahua; Chen, Wenru; Zhao, Rong
2014-06-04
Quality of life (QOL) for patients with coronary heart disease (CHD) is now concerned worldwide with the specific instruments being seldom and no one developed by the modular approach. This paper is aimed to develop the CHD scale of the system of Quality of Life Instruments for Chronic Diseases (QLICD-CHD) by the modular approach and validate it by both classical test theory and Generalizability Theory. The QLICD-CHD was developed based on programmed decision procedures with multiple nominal and focus group discussions, in-depth interview, pre-testing and quantitative statistical procedures. 146 inpatients with CHD were used to provide the data measuring QOL three times before and after treatments. The psychometric properties of the scale were evaluated with respect to validity, reliability and responsiveness employing correlation analysis, factor analyses, multi-trait scaling analysis, t-tests and also G studies and D studies of Genralizability Theory analysis. Multi-trait scaling analysis, correlation and factor analyses confirmed good construct validity and criterion-related validity when using SF-36 as a criterion. The internal consistency α and test-retest reliability coefficients (Pearson r and Intra-class correlations ICC) for the overall instrument and all domains were higher than 0.70 and 0.80 respectively; The overall and all domains except for social domain had statistically significant changes after treatments with moderate effect size SRM (standardized response mea) ranging from 0.32 to 0.67. G-coefficients and index of dependability (Ф coefficients) confirmed the reliability of the scale further with more exact variance components. The QLICD-CHD has good validity, reliability, and moderate responsiveness and some highlights, and can be used as the quality of life instrument for patients with CHD. However, in order to obtain better reliability, the numbers of items for social domain should be increased or the items' quality, not quantity, should be improved.
Boer, Annemarie; Dutmer, Alisa L; Schiphorst Preuper, Henrica R; van der Woude, Lucas H V; Stewart, Roy E; Deyo, Richard A; Reneman, Michiel F; Soer, Remko
2017-10-01
Validation study with cross-sectional and longitudinal measurements. To translate the US National Institutes of Health (NIH)-minimal dataset for clinical research on chronic low back pain into the Dutch language and to test its validity and reliability among people with chronic low back pain. The NIH developed a minimal dataset to encourage more complete and consistent reporting of clinical research and to be able to compare studies across countries in patients with low back pain. In the Netherlands, the NIH-minimal dataset has not been translated before and measurement properties are unknown. Cross-cultural validity was tested by a formal forward-backward translation. Structural validity was tested with exploratory factor analyses (comparative fit index, Tucker-Lewis index, and root mean square error of approximation). Hypothesis testing was performed to compare subscales of the NIH dataset with the Pain Disability Index and the EurQol-5D (Pearson correlation coefficients). Internal consistency was tested with Cronbach α and test-retest reliability at 2 weeks was calculated in a subsample of patients with Intraclass Correlation Coefficients and weighted Kappa (κω). In total, 452 patients were included of which 52 were included for the test-retest study. factor analysis for structural validity pointed into the direction of a seven-factor model (Cronbach α = 0.78). Factors and total score of the NIH-minimal dataset showed fair to good correlations with Pain Disability Index (r = 0.43-0.70) and EuroQol-5D (r = -0.41 to -0.64). Reliability: test-retest reliability per item showed substantial agreement (κω=0.65). Test-retest reliability per factor was moderate to good (Intraclass Correlation Coefficient = 0.71). The Dutch language version measurement properties of the NIH-minimal were satisfactory. N/A.
Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions.
Schmachtenberg, C; Engelken, F; Fischer, T; Bick, U; Poellinger, A; Fallenberg, E M
2012-07-01
Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. © Georg Thieme Verlag KG Stuttgart · New York.
Apivatgaroon, Adinun; Angthong, Chayanin; Sanguanjit, Prakasit; Chernchujit, Bancha
2016-10-01
To develop a Thai version of the Kujala score and show the evaluation of the validity and reliability of the score. The Thai version of the Kujala score was developed using the forward-backward translation protocol. The 49 PFPS patients answered the Thai version of questionnaires including the Kujala score, Short Form-36 (SF-36) and International Knee Documentation Committee (IKDC) Subjective Knee Form. The validity between the scores has been tested. The reliability was assessed using test-retest reliability and internal consistency. The Thai version of the Kujala score showed a good correlation with Thai IKDC Subjective Knee Form (Pearson's correlation coefficient; r = 0.74: p < 0.01) and moderate correlation with the Thai SF-36 subscales of physical component summary, total score and role physical (r = 0.586, 0.571 and 0.524, respectively: p < 0.01). The test-retest reliability was excellent with an intra-class correlation coefficient of 0.908 (p < 0.001; 95% CI [0.842-0.947]). The internal consistency was strong with Cronbach's alpha of 0.952 (p < 0.001). No floor and ceiling effects were observed. The Thai version of the Kujala score has shown good validity and reliability. This score can be effectively used for evaluating Thai patients with patellofemoral pain syndrome. Implications for Rehabilitation The Kujala score is a self-administered questionnaire for patients with patellofemoral pain syndrome (PFPS). The validity and reliability of the Thai version of Kujala are compatible with other versions (Turkish, Chinese and Persian version). The Thai version of Kujala has been shown to have validity and reliability in Thai PFPS patients and can be used for clinical evaluation and also in the research work.
Praxedes, Marcus Fernando da Silva; de Abreu, Mauro Henrique Nogueira Guimarães; Paiva, Saul Martins; Mambrini, Juliana Vaz de Melo; Marcolino, Milena Soriano; Martins, Maria Auxiliadora Parreiras
2016-06-24
The aim of this study was to evaluate the psychometric properties of the Brazilian version of the Oral Anticoagulation Knowledge (OAK) Test. This study, conducted in an anticoagulation clinic, included 201 Brazilian participants aged over 18 years, who had been using warfarin for more than two months. The reliability of the instrument was evaluated by assessing internal consistency (Kuder-Richardson coefficient) and reproducibility (test-retest reliability). The validity was evaluated by hypothesizing that there would be a positive correlation of moderate to strong intensity between the correctness levels of the OAK Test and time within therapeutic range (TTR) values, which is a measure used to evaluate the quality of oral anticoagulation. The instrument exhibited good psychometric properties. The total a Kuder-Richardson coefficient value was 0.818 and intraclass correlation coefficient was 0.967. The validity revealed a strong positive correlation between the values of the level of knowledge, as measured by the OAK Test and the TTR values (rs = 0.780). The instrument proved to be a reliable and valid tool for evaluating the knowledge of Brazilian patients on oral anticoagulation therapy with warfarin. This instrument may be incorporated into the practice of health care for substantiating the structuring of educational activities to ensure the improvement of knowledge about the use of warfarin, thereby increasing the effectiveness and safety of treatment.
Development and Validation of a Fatigue Assessment Scale for U.S. Construction Workers
Zhang, Mingzong; Sparer, Emily H.; Murphy, Lauren A.; Dennerlein, Jack T.; Fang, Dongping; Katz, Jeffrey N.; Caban-Martinez, Alberto J.
2015-01-01
Objective To develop a fatigue assessment scale and test its reliability and validity for commercial construction workers. Methods Using a two-phased approach, we first identified items for the development of a Fatigue Assessment Scale for Construction Workers (FASCW) through review of existing scales in the scientific literature, key informant interviews (n=11) and focus groups (3 groups with 6 workers each) with construction workers. The second phase included assessment for the reliability, validity and sensitivity of the new scale using a repeated-measures study design with a convenience sample of construction workers (n=144). Results Phase one resulted in a 16-item preliminary scale that after factor analysis yielded a final 10-item scale with two sub-scales (“Lethargy” and “Bodily Ailment”).. During phase two, the FASCW and its subscales demonstrated satisfactory internal consistency (alpha coefficients were FASCW (0.91), Lethargy (0.86) and Bodily Ailment (0.84)) and acceptable test-retest reliability (Pearson Correlations Coefficients: 0.59–0.68; Intraclass Correlation Coefficients: 0.74–0.80). Correlation analysis substantiated concurrent and convergent validity. A discriminant analysis demonstrated that the FASCW differentiated between groups with arthritis status and different work hours. Conclusions The 10-item FASCW with good reliability and validity is an effective tool for assessing the severity of fatigue among construction workers. PMID:25603944
Assessment of the vision-specific quality of life using clustered visual field in glaucoma patients.
Sawada, Hideko; Yoshino, Takaiko; Fukuchi, Takeo; Abe, Haruki
2014-02-01
To investigate the significance of vision-specific quality of life (QOL) in glaucoma patients based on the location of visual field defects. We examined 336 eyes of 168 patients. The 25-item National Eye Institute Visual Function Questionnaire was used to evaluate patients' QOL. Visual field testing was performed using the Humphrey Field Analyzer; the visual field was divided into 10 clusters. We defined the eye with better mean deviation as the better eye and the fellow eye as the worse eye. A single linear regression analysis was applied to assess the significance of the relationship between QOL and the clustered visual field. The strongest correlation was observed in the lower paracentral visual field in the better eye. The lower peripheral visual field in the better eye also showed a good correlation. Correlation coefficients in the better eye were generally higher than those in the worse eye. For driving, the upper temporal visual field in the better eye was the most strongly correlated (r=0.509). For role limitation and peripheral vision, the lower peripheral visual field in the better eye had the highest correlation coefficients at 0.459 and 0.425, respectively. Overall, clusters in the lower hemifield in the better eye were more strongly correlated with QOL than those in the worse eye. In particular, the lower paracentral visual field in the better eye was correlated most strongly of all. Driving, however, strongly correlated with the upper hemifield in the better eye.
Validation of the Chinese Version of the Quality of Nursing Work Life Scale
Fu, Xia; Xu, Jiajia; Song, Li; Li, Hua; Wang, Jing; Wu, Xiaohua; Hu, Yani; Wei, Lijun; Gao, Lingling; Wang, Qiyi; Lin, Zhanyi; Huang, Huigen
2015-01-01
Quality of Nursing Work Life (QNWL) serves as a predictor of a nurse’s intent to leave and hospital nurse turnover. However, QNWL measurement tools that have been validated for use in China are lacking. The present study evaluated the construct validity of the QNWL scale in China. A cross-sectional study was conducted conveniently from June 2012 to January 2013 at five hospitals in Guangzhou, which employ 1938 nurses. The participants were asked to complete the QNWL scale and the World Health Organization Quality of Life abbreviated version (WHOQOL-BREF). A total of 1922 nurses provided the final data used for analyses. Sixty-five nurses from the first investigated division were re-measured two weeks later to assess the test-retest reliability of the scale. The internal consistency reliability of the QNWL scale was assessed using Cronbach’s α. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC). Criterion-relation validity was assessed using the correlation of the total scores of the QNWL and the WHOQOL-BREF. Construct validity was assessed with the following indices: χ2 statistics and degrees of freedom; relative mean square error of approximation (RMSEA); the Akaike information criterion (AIC); the consistent Akaike information criterion (CAIC); the goodness-of-fit index (GFI); the adjusted goodness of fit index; and the comparative fit index (CFI). The findings demonstrated high internal consistency (Cronbach’s α = 0.912) and test-retest reliability (interclass correlation coefficient = 0.74) for the QNWL scale. The chi-square test (χ2 = 13879.60, df [degree of freedom] = 813 P = 0.0001) was significant. The RMSEA value was 0.091, and AIC = 1806.00, CAIC = 7730.69, CFI = 0.93, and GFI = 0.74. The correlation coefficient between the QNWL total scores and the WHOQOL-BREF total scores was 0.605 (p<0.01). The QNWL scale was reliable and valid in Chinese-speaking nurses and could be used as a clinical and research instrument for measuring work-related factors among nurses in China. PMID:25950838
Kent, Katherine; Charlton, Karen
2017-01-01
There is a large burden on researchers and participants when attempting to accurately measure dietary flavonoid intake using dietary assessment. Minimizing participant and researcher burden when collecting dietary data may improve the validity of the results, especially in older adults with cognitive impairment. A short 14-item food frequency questionnaire (FFQ) to measure flavonoid intake, and flavonoid subclasses (anthocyanins, flavan-3-ols, flavones, flavonols, and flavanones) was developed and assessed for validity and reproducibility against a 24-hour recall. Older adults with mild-moderate dementia (n = 49) attended two interviews 12 weeks apart. With the assistance of a family carer, a 24-h recall was collected at the first interview, and the flavonoid FFQ was interviewer-administered at both time-points. Validity and reproducibility was assessed using the Wilcoxon signed-rank sum test, Spearman's correlation coefficient, Bland-Altman Plots, and Cohen's kappa. Mean flavonoid intake was determined (FFQ1 = 795 ± 492.7 mg/day, 24-h recall = 515.6 ± 384.3 mg/day). Tests of validity indicated the FFQ was better at estimating total flavonoid intake than individual flavonoid subclasses compared with the 24-h recall. There was a significant difference in total flavonoid intake estimates between the FFQ and the 24-h recall (Wilcoxon signed-rank sum p < 0.001; Bland-Altman plots indicated large bias and wide limits of agreement), but they were well correlated (Spearman's correlation coefficient r = 0.74, p < 0.001; Cohen's kappa κ = 0.292, p < 0.001). The FFQ showed good reproducibility, with a small mean percentage difference (12.6%). The Wilcoxon signed-rank sum test showed no significant difference, Spearman's correlation coefficient indicated excellent reliability (r = 0.75, p < 0.001), Bland-Altman plots visually showed small, nonsignificant bias and wide limits of agreement, and Cohen's kappa indicated fair agreement (κ = 0.429, p < 0.001). A 14-item FFQ developed to easily measure flavonoid intake in older adults with dementia demonstrates fair validity against a 24-h recall and good reproducibility.
Pereira, Taísa Sabrina Silva; Cade, Nágela Valadão; Mill, José Geraldo; Sichieri, Rosely; Molina, Maria del Carmen Bisi
2016-01-01
Introduction Biomarkers are a good choice to be used in the validation of food frequency questionnaire due to the independence of their random errors. Objective To assess the validity of the potassium and sodium intake estimated using the Food Frequency Questionnaire ELSA-Brasil. Subjects/Methods A subsample of participants in the ELSA-Brasil cohort was included in this study in 2009. Sodium and potassium intake were estimated using three methods: Semi-quantitative food frequency questionnaire, 12-hour nocturnal urinary excretion and three 24-hour food records. Correlation coefficients were calculated between the methods, and the validity coefficient was calculated using the method of triads. The 95% confidence intervals for the validity coefficient were estimated using bootstrap sampling. Exact and adjacent agreement and disagreement of the estimated sodium and potassium intake quintiles were compared among three methods. Results The sample consisted of 246 participants, aged 53±8 years, 52% of women. Validity coefficient for sodium were considered weak (рfood frequency questionnaire actual intake = 0.37 and рbiomarker actual intake = 0.21) and moderate (рfood records actual intake 0.56). The validity coefficient were higher for potassium (рfood frequency questionnaire actual intake = 0.60; рbiomarker actual intake = 0.42; рfood records actual intake = 0.79). Conclusions: The Food Frequency Questionnaire ELSA-Brasil showed good validity in estimating potassium intake in epidemiological studies. For sodium validity was weak, likely due to the non-quantification of the added salt to prepared food. PMID:28030625
Pereira, Taísa Sabrina Silva; Cade, Nágela Valadão; Mill, José Geraldo; Sichieri, Rosely; Molina, Maria Del Carmen Bisi
2016-01-01
Biomarkers are a good choice to be used in the validation of food frequency questionnaire due to the independence of their random errors. To assess the validity of the potassium and sodium intake estimated using the Food Frequency Questionnaire ELSA-Brasil. A subsample of participants in the ELSA-Brasil cohort was included in this study in 2009. Sodium and potassium intake were estimated using three methods: Semi-quantitative food frequency questionnaire, 12-hour nocturnal urinary excretion and three 24-hour food records. Correlation coefficients were calculated between the methods, and the validity coefficient was calculated using the method of triads. The 95% confidence intervals for the validity coefficient were estimated using bootstrap sampling. Exact and adjacent agreement and disagreement of the estimated sodium and potassium intake quintiles were compared among three methods. The sample consisted of 246 participants, aged 53±8 years, 52% of women. Validity coefficient for sodium were considered weak (рfood frequency questionnaire actual intake = 0.37 and рbiomarker actual intake = 0.21) and moderate (рfood records actual intake 0.56). The validity coefficient were higher for potassium (рfood frequency questionnaire actual intake = 0.60; рbiomarker actual intake = 0.42; рfood records actual intake = 0.79). Conclusions: The Food Frequency Questionnaire ELSA-Brasil showed good validity in estimating potassium intake in epidemiological studies. For sodium validity was weak, likely due to the non-quantification of the added salt to prepared food.
Elliptic and triangular flow in p-Pb and peripheral Pb-Pb collisions from parton scatterings
Bzdak, Adam; Ma, Guo-Liang
2014-12-15
Using a multiphase transport model (AMPT) we calculate the elliptic v₂ and triangular v₃ Fourier coefficients of the two-particle azimuthal correlation function in proton-nucleus (p-Pb) and peripheral nucleus-nucleus (Pb-Pb) collisions. Our results for v₃ are in a good agreement with the CMS data collected at the Large Hadron Collider. The v₂ coefficient is very well described in p-Pb collisions and is underestimated for higher transverse momenta in Pb-Pb interactions. The characteristic mass ordering of v₂ in p-Pb is reproduced, whereas for v₃, this effect is not observed. We further predict the pseudorapidity dependence of v₂ and v₃ in p-Pb andmore » observe that both are increasing when going from a proton side to a Pb-nucleus side. Predictions for the higher-order Fourier coefficients, v₄ and v₅, in p-Pb are also presented.« less
NASA Technical Reports Server (NTRS)
Choudhury, B. J.; Blanchard, B. J.
1981-01-01
The antecedent precipitation index (API) is a useful indicator of soil moisture conditions for watershed runoff calculations and recent attempts to correlate this index with spaceborne microwave observations have been fairly successful. It is shown that the prognostic equation for soil moisture used in some of the atmospheric general circulation models together with Thornthwaite-Mather parameterization of actual evapotranspiration leads to API equations. The recession coefficient for API is found to depend on climatic factors through potential evapotranspiration and on soil texture through the field capacity and the permanent wilting point. Climatologial data for Wisconsin together with a recently developed model for global isolation are used to simulate the annual trend of the recession coefficient. Good quantitative agreement is shown with the observed trend at Fennimore and Colby watersheds in Wisconsin. It is suggested that API could be a unifying vocabulary for watershed and atmospheric general circulation modelars.
Johansson, Fredrik R.; Skillgate, Eva; Lapauw, Mattis L.; Clijmans, Dorien; Deneulin, Valentijn P.; Palmans, Tanneke; Engineer, Human Kinetic; Cools, Ann M.
2015-01-01
Context Shoulder strength assessment plays an important role in the clinical examination of the shoulder region. Eccentric strength measurements are of special importance in guiding the clinician in injury prevention or return-to-play decisions after injury. Objective To examine the absolute and relative reliability and validity of a standardized eccentric strength-measurement protocol for the glenohumeral external rotators. Design Descriptive laboratory study. Setting Testing environment at the Department of Rehabilitation Sciences and Physiotherapy of Ghent University, Belgium. Patients or Other Participants Twenty-five healthy participants (9 men and 16 women) without any history of shoulder pain were tested by 2 independent assessors using a handheld dynamometer (HHD) and underwent an isokinetic testing procedure. Intervention(s) The clinical protocol used an HHD, a DynaPort accelerometer to measure acceleration and angular velocity of testing 30°/s over 90° of range of motion, and a Biodex dynamometer to measure isokinetic activity. Main Outcome Measure(s) Three eccentric strength measurements: (1) tester 1 with the HHD, (2) tester 2 with the HHD, and (3) Biodex isokinetic strength measurement. Results The intratester reliability was excellent (0.879 and 0.858), whereas the intertester reliability was good, with an intraclass correlation coefficient between testers of 0.714. Pearson product moment correlation coefficients of 0.78 and 0.70 were noted between the HHD and the isokinetic data, showing good validity of this new procedure. Conclusions Standardized eccentric rotator cuff strength can be tested and measured in the clinical setting with good-to-excellent reliability and validity using an HHD. PMID:25974381
Salamh, Paul A; Kolber, Morey
2014-01-01
To investigate the reliability, minimal detectable change (MDC90) and concurrent validity of a gravity-based bubble inclinometer (inclinometer) and iPhone® application for measuring standing lumbar lordosis. Two investigators used both an inclinometer and an iPhone® with an inclinometer application to measure lumbar lordosis of 30 asymptomatic participants. ICC models 3,k and 2,k were used for the intrarater and interrater analysis, respectively. Good interrater and intrarater reliability was present for the inclinometer with Intraclass Correlation Coefficients (ICC) of 0.90 and 0.85, respectively and the iPhone® application with ICC values of 0.96 and 0.81. The minimal detectable change (MDC90) indicates that a change greater than or equal to 7° and 6° is needed to exceed the threshold of error using the iPhone® and inclinometer, respectively. The concurrent validity between the two instruments was good with a Pearson product-moment coefficient of correlation (r) of 0.86 for both raters. Ninety-five percent limits of agreement identified differences ranging from 9° greater in regards to the iPhone® to 8° less regarding the inclinometer. Both the inclinometer and iPhone® application possess good interrater reliability, intrarater reliability and concurrent validity for measuring standing lumbar lordosis. This investigation provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying standing lumbar lordosis. Clinicians should recognize potential individual differences when using these devices interchangeably.
A new approach for measuring the work and quality of histopathology reporting.
Sharma, Vijay; Davey, Jonathan G N; Humphreys, Catherine; Johnston, Peter W
2013-07-01
Cancer datasets drive report quality, but require more work to inform compliant reports. The aim of this study was to correlate the number of words with measures of quality, to examine the impact of the drive for improved quality on the workload of histopathology reporting over time. We examined the first 10 reports of colon, breast, renal, lung and ovarian carcinoma, melanoma resection, nodal lymphoma appendicitis and seborrhoeic keratosis (SK) issued in 1991, 2001 and 2011. Correlations were analysed using Pearson's partial correlation coefficients. Word count increased significantly over time for most specimen types examined. Word count almost always correlated with units of information, indicating that the word count was a good measure of the amount of information contained within the reports; this correlation was preserved following correction for the effect of time. A good correlation with compliance with cancer datasets was also observed, but was weakened or lost following correction for the increase in word count and units of information that occurred between time points. These data indicate that word count could potentially be used as a measure of information content if its integrity and usefulness are continuously validated. Further prospective studies are required to assess and validate this approach. © 2013 John Wiley & Sons Ltd.
A new correlation coefficient for bivariate time-series data
NASA Astrophysics Data System (ADS)
Erdem, Orhan; Ceyhan, Elvan; Varli, Yusuf
2014-11-01
The correlation in time series has received considerable attention in the literature. Its use has attained an important role in the social sciences and finance. For example, pair trading in finance is concerned with the correlation between stock prices, returns, etc. In general, Pearson’s correlation coefficient is employed in these areas although it has many underlying assumptions which restrict its use. Here, we introduce a new correlation coefficient which takes into account the lag difference of data points. We investigate the properties of this new correlation coefficient. We demonstrate that it is more appropriate for showing the direction of the covariation of the two variables over time. We also compare the performance of the new correlation coefficient with Pearson’s correlation coefficient and Detrended Cross-Correlation Analysis (DCCA) via simulated examples.
Liu, Zifeng; Yuan, Lianxiong; Huang, Yixiang; Zhang, Lingling; Luo, Futian
2016-01-01
Objective We aimed to develop a questionnaire for quantitative evaluation of the autonomy of public hospitals in China. Method An extensive literature review was conducted to select possible items for inclusion in the questionnaire, which was then reviewed by 5 experts. After a two-round Delphi method, we distributed the questionnaire to 404 secondary and tertiary hospitals in Guangdong Province, China, and 379 completed questionnaires were collected. The final questionnaire was then developed on the basis of the results of exploratory and confirmatory factor analysis. Results Analysis suggested that all internal consistency reliabilities exceeded the minimum reliability standard of 0.70 for the α coefficient. The overall scale coefficient was 0.87, and 6 subscale coefficients were 0.92 (strategic management), 0.81 (budget and expenditure), 0.85 (financing), 0.75 (financing, medical management), 0.86 (human resources) and 0.86 (accountability). Correlation coefficients between and among items and their hypothesised subscales were higher than those with other subscales. The value of average variance extracted (AVE) was higher than 0.5, the value of construct reliability (CR) was higher than 0.7, and the square roots of the AVE of each subscale were larger than the correlation of the specific subscale with the other subscales, supporting the convergent and discriminant validity of the Chinese version of the Hospital Autonomy Questionnaire (CVHAQ). The model fit indices were all acceptable: χ2/df=1.73, Goodness of Fit Index (GFI) = 0.93, Adjusted Goodness of Fit Index (AGFI) = 0.91, Non-Normed Fit Index (NNFI) = 0.96, Comparative Fit Index (CFI) = 0.97, Root Mean Square Error of Approximation (RMSEA) = 0.04, Standardised Root Mean Square Residual (SRMR) = 0.07. Conclusions This study demonstrated the reliability and validity of a CVHAQ and provides a quantitative method for the assessment of hospital autonomy. PMID:26911587
Studies on convective heat transfer through helical coils
NASA Astrophysics Data System (ADS)
Pawar, S. S.; Sunnapwar, Vivek K.
2013-12-01
An experimental investigation on steady state convection heat transfer from vertical helical coiled tubes in water was performed for laminar flow regime. Three coils with curvature ratios as 0.0757, 0.064, 0.055 and range of Prandtl number from 3.81 to 4.8, Reynolds number from 3,166 to 9,658 were considered in this work. The heat transfer data were generated from 30 experiments conducted at constant water bath temperature (60 °C) for different cold water flow rates in helical coils. For the first time, an innovative approach of correlating Nusselt number with ‘M’ number is proposed which is not available in the literature and the developed correlations are found to be in good agreement with the work of earlier researchers. Thus, dimensionless number ‘M’ was found to be significant to characterize the hydrodynamics of fluid flow and heat transfer correlations in helical coils. Several other correlations based on experimental data are developed. To cover wide range of industrial applications, suitable generalized correlations based on extended parameters beyond the range of present experimental work are also developed. All these correlations are developed by using least-squares power law fit and multiple-regression analysis of MATLAB software. Correlations so developed were compared with published correlations and were found to be in good agreement. Comparison of heat transfer coefficients, friction factor and Nusselt number for different geometrical conditions is presented in this paper.
Pulmonary disease in cystic fibrosis: assessment with chest CT at chest radiography dose levels.
Ernst, Caroline W; Basten, Ines A; Ilsen, Bart; Buls, Nico; Van Gompel, Gert; De Wachter, Elke; Nieboer, Koenraad H; Verhelle, Filip; Malfroot, Anne; Coomans, Danny; De Maeseneer, Michel; de Mey, Johan
2014-11-01
To investigate a computed tomographic (CT) protocol with iterative reconstruction at conventional radiography dose levels for the assessment of structural lung abnormalities in patients with cystic fibrosis ( CF cystic fibrosis ). In this institutional review board-approved study, 38 patients with CF cystic fibrosis (age range, 6-58 years; 21 patients <18 years and 17 patients >18 years) underwent investigative CT (at minimal exposure settings combined with iterative reconstruction) as a replacement of yearly follow-up posteroanterior chest radiography. Verbal informed consent was obtained from all patients or their parents. CT images were randomized and rated independently by two radiologists with use of the Bhalla scoring system. In addition, mosaic perfusion was evaluated. As reference, the previous available conventional chest CT scan was used. Differences in Bhalla scores were assessed with the χ(2) test and intraclass correlation coefficients ( ICC intraclass correlation coefficient s). Radiation doses for CT and radiography were assessed for adults (>18 years) and children (<18 years) separately by using technical dose descriptors and estimated effective dose. Differences in dose were assessed with the Mann-Whitney U test. The median effective dose for the investigative protocol was 0.04 mSv (95% confidence interval [ CI confidence interval ]: 0.034 mSv, 0.10 mSv) for children and 0.05 mSv (95% CI confidence interval : 0.04 mSv, 0.08 mSv) for adults. These doses were much lower than those with conventional CT (median: 0.52 mSv [95% CI confidence interval : 0.31 mSv, 3.90 mSv] for children and 1.12 mSv [95% CI confidence interval : 0.57 mSv, 3.15 mSv] for adults) and of the same order of magnitude as those for conventional radiography (median: 0.012 mSv [95% CI confidence interval : 0.006 mSv, 0.022 mSv] for children and 0.012 mSv [95% CI confidence interval : 0.005 mSv, 0.031 mSv] for adults). All images were rated at least as diagnostically acceptable. Very good agreement was found in overall Bhalla score ( ICC intraclass correlation coefficient , 0.96) with regard to the severity of bronchiectasis ( ICC intraclass correlation coefficient , 0.87) and sacculations and abscesses ( ICC intraclass correlation coefficient , 0.84). Interobserver agreement was excellent ( ICC intraclass correlation coefficient , 0.86-1). For patients with CF cystic fibrosis , a dedicated chest CT protocol can replace the two yearly follow-up chest radiographic examinations without major dose penalty and with similar diagnostic quality compared with conventional CT.
Genome-scale cluster analysis of replicated microarrays using shrinkage correlation coefficient.
Yao, Jianchao; Chang, Chunqi; Salmi, Mari L; Hung, Yeung Sam; Loraine, Ann; Roux, Stanley J
2008-06-18
Currently, clustering with some form of correlation coefficient as the gene similarity metric has become a popular method for profiling genomic data. The Pearson correlation coefficient and the standard deviation (SD)-weighted correlation coefficient are the two most widely-used correlations as the similarity metrics in clustering microarray data. However, these two correlations are not optimal for analyzing replicated microarray data generated by most laboratories. An effective correlation coefficient is needed to provide statistically sufficient analysis of replicated microarray data. In this study, we describe a novel correlation coefficient, shrinkage correlation coefficient (SCC), that fully exploits the similarity between the replicated microarray experimental samples. The methodology considers both the number of replicates and the variance within each experimental group in clustering expression data, and provides a robust statistical estimation of the error of replicated microarray data. The value of SCC is revealed by its comparison with two other correlation coefficients that are currently the most widely-used (Pearson correlation coefficient and SD-weighted correlation coefficient) using statistical measures on both synthetic expression data as well as real gene expression data from Saccharomyces cerevisiae. Two leading clustering methods, hierarchical and k-means clustering were applied for the comparison. The comparison indicated that using SCC achieves better clustering performance. Applying SCC-based hierarchical clustering to the replicated microarray data obtained from germinating spores of the fern Ceratopteris richardii, we discovered two clusters of genes with shared expression patterns during spore germination. Functional analysis suggested that some of the genetic mechanisms that control germination in such diverse plant lineages as mosses and angiosperms are also conserved among ferns. This study shows that SCC is an alternative to the Pearson correlation coefficient and the SD-weighted correlation coefficient, and is particularly useful for clustering replicated microarray data. This computational approach should be generally useful for proteomic data or other high-throughput analysis methodology.
Tests of Hypotheses Arising In the Correlated Random Coefficient Model*
Heckman, James J.; Schmierer, Daniel
2010-01-01
This paper examines the correlated random coefficient model. It extends the analysis of Swamy (1971), who pioneered the uncorrelated random coefficient model in economics. We develop the properties of the correlated random coefficient model and derive a new representation of the variance of the instrumental variable estimator for that model. We develop tests of the validity of the correlated random coefficient model against the null hypothesis of the uncorrelated random coefficient model. PMID:21170148
Fone, David L; Christie, Stephen; Lester, Nathan
2006-04-13
Assessment of the spatial accessibility of hospital accident and emergency departments as perceived by local residents has not previously been investigated. Perceived accessibility may affect where, when, and whether potential patients attend for treatment. Using data on 11,853 respondents to a population survey in Caerphilly county borough, Wales, UK, we present an analysis comparing the accessibility of accident and emergency departments as reported by local residents and drive-time to the nearest accident and emergency department modelled using a geographical information system (GIS). Median drive-times were significantly shorter in the lowest perceived access category and longer in the best perceived access category (p < 0.001). The perceived access and GIS modelled drive-time variables were positively correlated (Spearman's rank correlation coefficient, r = 0.38, p < 0.01). The strongest correlation was found for respondents living in areas in which nearly all households had a car or van (r = 0.47, p < 0.01). Correlations were stronger among respondents reporting good access to public transport and among those reporting a recent accident and emergency attendance for injury treatment compared to other respondents. Correlation coefficients did not vary substantially by levels of household income. Drive-time, road distance and straight-line distance were highly inter-correlated and substituting road distance or straight-line distance as the GIS modelled spatial accessibility measure only marginally decreased the magnitude of the correlations between perceived and GIS modelled access. This study provides evidence that the accessibility of hospital-based health care services as perceived by local residents is related to measures of spatial accessibility modelled using GIS. For studies that aim to model geographical separation in a way that correlates well with the perception of local residents, there may be minimal advantage in using sophisticated measures. Straight-line distance, which can be calculated without GIS, may be as good as GIS-modelled drive-time or distance for this purpose. These findings will be of importance to health policy makers and local planners who seek to obtain local information on access to services through focussed assessments of residents' concerns over accessibility and GIS modelling.
Schneider, Antonius; Szecsenyi, Joachim; Barie, Stefan; Joest, Katharina; Rosemann, Thomas
2007-01-01
Background The aim of the study was to examine the validity of a translated and culturally adapted version of the Physicians' Reaction to Uncertainty scales (PRU) in primary care physicians. Methods In a structured process, the original questionnaire was translated, culturally adapted and assessed after administering it to 93 GPs. Test-retest reliability was tested by sending the questionnaire to the GPs again after two weeks. Results The principal factor analysis confirmed the postulated four-factor structure underlying the 15 items. In contrast to the original version, item 5 achieved a higher loading on the 'concern about bad outcomes' scale. Consequently, we rearranged the scales. Good item-scale correlations were obtained, with Pearson's correlation coefficient ranging from 0.56–0.84. As regards the item-discriminant validity between the scales 'anxiety due to uncertainty' and 'concern about bad outcomes', partially high correlations (Pearson's correlation coefficient 0.02–0.69; p < 0.001) were found, indicating an overlap between both constructs. The assessment of internal consistency revealed satisfactory values; Cronbach's alpha of the rearranged version was 0.86 or higher for all scales. Test-retest-reliability, assessed by means of the intraclass-correlation-coefficient (ICC), exceeded 0.84, except for the 'reluctance to disclose mistakes to physicians' scale (ICC = 0.66). In this scale, some substantial floor effects occurred, with 29.3% of answers showing the lowest possible value. Conclusion Dealing with uncertainty is an important issue in daily practice. The psychometric properties of the rearranged German version of the PRU are satisfying. The revealed floor effects do not limit the significance of the questionnaire. Thus, the German version of the PRU could contribute to the further evaluation of the impact of uncertainty in primary care physicians. PMID:17562018
Gunaydin, Gurkan; Citaker, Seyit; Meray, Jale; Cobanoglu, Gamze; Gunaydin, Ozge Ece; Hazar Kanik, Zeynep
2016-11-01
Validation of a self-report questionnaire. The purpose of this study was to investigate adaptation, validity, and reliability of the Turkish version of the Bournemouth Questionnaire. Low back pain is one of the most frequent disorders leading to activity limitation. This pain affects most of people in their lives. The most important point to evaluate patient's functional abilities and to decide a successful therapy procedure is to manage the assessment questionnaires precisely. One hundred ten patients with chronic low back pain were included in present study. To assess reliability, test-retest and internal consistency analyses were applied. The results of test-retest analysis were assessed by using Intraclass Correlation Coefficient method (95% confidence interval). For internal consistency, Cronbach alpha value was calculated. Validity of the questionnaire was assessed in terms of construct validity. For construct validity, factor analysis and convergent validity were tested. For convergent validity, total points of the Bournemouth Questionnaire were assessed with the total points of Quebec Back Pain Disability Scale and Roland Morris Disability Questionnaire by using Pearson correlation coefficient analysis. Cronbach alpha value was found 0.914, showing that this questionnaire has high internal consistency. The results of test-retest analysis were varying between 0.851 and 0.927, which shows that test-retest results are highly correlated. Factor analysis test indicated that this questionnaire had one factor. Pearson correlation coefficient of the Bournemouth Questionnaire with Roland Morris Disability Questionnaire was calculated 0.703 and it was found with Quebec Back Pain Disability Scale is 0.659. These results showed that the Bournemouth Questionnaire is very good correlated with Roland Morris Disability Questionnaire and Quebec Back Pain Disability Scale. The Turkish version of the Bournemouth Questionnaire is valid and reliable. 3.
Lee, Hsiang-Ching; Zhang, Li-Fan; Lin, Jyh-Ling; Chin, Yuan-Lung; Sun, Tai-Ping
2013-10-21
The purpose of this study was to develop novel nanoscale biosensors using titania nanotubes (TNTs) made by anodization. Titania nanotubes were produced on pure titanium sheets by anodization at room temperature. In this research, the electrolyte composition ethylene glycol 250 mL/NH4F 1.5 g/DI water 20 mL was found to produce the best titania nanotubes array films for application in amperometric biosensors. The amperometric results exhibit an excellent linearity for uric acid (UA) concentrations in the range between 2 and 14 mg/dL, with 23.3 (µA·cm-2)·(mg/dL)-1 UA sensitivity, and a correlation coefficient of 0.993. The glucose biosensor presented a good linear relationship in the lower glucose concentration range between 50 and 125 mg/dL, and the corresponding sensitivity was approximately 249.6 (µA·cm-2)·(100 mg/dL)-1 glucose, with a correlation coefficient of 0.973.
Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish
Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan
2015-01-01
Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.
NASA Astrophysics Data System (ADS)
Sogukpinar, Haci; Bozkurt, Ismail
2018-02-01
Aerodynamic performance of the airfoil plays the most important role to obtain economically maximum efficiency from a wind turbine. Therefore airfoil should have an ideal aerodynamic shape. In this study, aerodynamic simulation of S809 airfoil is conducted and obtained result compared with previously made NASA experimental result and NREL theoretical data. At first, Lift coefficient, lift to drag ratio and pressure coefficient around S809 airfoil are calculated with SST turbulence model, and are compared with experimental and other theoretical data to correlate simulation correctness of the computational approaches. And result indicates good correlation with both experimental and theoretical data. This calculation point out that as the increasing relative velocity, lift to drag ratio increases. Lift to drag ratio attain maximum at the angle around 6 degree and after that starts to decrease again. Comparison shows that CFD code used in this calculation can predict aerodynamic properties of airfoil.
Selected results of the F-15 propulsion interactions program
NASA Technical Reports Server (NTRS)
Webb, L. D.; Nugent, J.
1982-01-01
A better understanding of propulsion system/airframe flow interactions could aid in the reduction of aircraft drag. For this purpose, NASA and the United States Air Force have conducted a series of wind-tunnel and flight tests on the F-15 airplane. This paper presents a correlation of flight test data from tests conducted at the NASA Dryden Flight Research Facility of the Ames Research Center, with data obtained from wind-tunnel tests. Flights were made at stabilized Mach numbers around 0.6, 0.9, 1.2, and 1.5 with accelerations up to near Mach number 2. Wind-tunnel tests used a 7.5 percent-scale F-15 inlet/airframe model. Flight and wind-tunnel pressure coefficients showed good agreement in most cases. Correlation of interaction effects caused by changes in cowl angle, angle-of-attack, and Mach number are presented. For the afterbody region, the pressure coefficients on the nozzle surfaces were influenced by boattail angles and Mach number. Boundary-layer thickness decreased as angle of attack increased above 4 deg.
NASA Astrophysics Data System (ADS)
Robles-Gonzalez, Cristina; Fernandez-Renau, Alix; Lopez Gordillo, Noelia; Sevilla, Angel Garcia; Suarez, Juana Santana
2010-12-01
Since 1997, the INTA-CREPAD (Centre for REception, Processing, Archiving and Dissemination of Earth Observation Data) program distributes freely some of the most demanded low-resolution remote sensing products: SST, Ocean Chl-a, NDVI, AOD... The data input for such products are captured at the Canary Space Station (Centro Espacial de Canarias, CEC). The data sensors received at the station and used in the CREPAD program are AVHRR, SEAWIFS and MODIS. In this study SST and AOD retrieved by CREPAD algorithms from AVHRR and the SEADAS derived SST and AOD from MODIS have compared. SST values agree very well within 0.1±0.5oC and the coefficient of correlation of the images is 0.9. AOD validation gives good results taking into account the differences in the algorithms used. Mean AOD difference at 0.630 μm is 0.01±0.05 and the correlation coefficient is 0.6.
Study of V-OTDR stability for dynamic strain measurement in piezoelectric vibration
NASA Astrophysics Data System (ADS)
Ren, Meiqi; Lu, Ping; Chen, Liang; Bao, Xiaoyi
2016-09-01
In a phase-sensitive optical-time domain reflectometry (Φ-OTDR) system, the challenge for dynamic strain measurement lies in large intensity fluctuations from trace to trace. The intensity fluctuation caused by stochastic characteristics of Rayleigh backscattering sets detection limit for the minimum strength of vibration measurement and causes the large measurement uncertainty. Thus, a trace-to-trace correlation coefficient is introduced to quantify intensity fluctuation of Φ-OTDR traces and stability of the sensor system theoretically and experimentally. A novel approach of measuring dynamic strain induced by various driving voltages of lead zirconate titanate (PZT) in Φ-OTDR is also demonstrated. Piezoelectric vibration signals are evaluated through analyzing peak values of fast Fourier transform spectra at the fundamental frequency and high-order harmonics based on Bessel functions. High trace-to-trace correlation coefficients varying from 0.824 to 0.967 among 100 measurements are obtained in experimental results, showing the good stability of our sensor system, as well as small uncertainty of measured peak values.
Denova-Gutiérrez, Edgar; Ramírez-Silva, Ivonne; Rodríguez-Ramírez, Sonia; Jiménez-Aguilar, Alejandra; Shamah-Levy, Teresa; Rivera-Dommarco, Juan A
2016-01-01
To assess the validity of a 140-item semiquantitative food frequency questionnaire (SFFQ), in Mexican adolescents and adults. Dietary intakes using a SFFQ and two 24-hour dietary recalls (24DRs), in nonconsecutive days during the same week were measured from 178 adolescents and 230 adults participating in the Mexican National Health and Nutrition Survey-2012.Validity was evaluated using correlation coefficients (CC),deattenuated CC, linear regression models, cross-classification analysis, and the Bland-Altman method. In adults, deattenuated correlation coefficients between the SFFQ and the 24DRs ranged from 0.30 for folate to 0.61 for saturated fat. In addition, 63% adults and 62% adolescents were classified in the same and adjacent quartile of nutrient intake when comparing data from SFFQ and 24DRs. The SFFQ had moderate validity for energy, macronutrients and micronutrients. It also had good validity to rank individuals according to their dietary intake of different nutrients.
Lee, Hsiang-Ching; Zhang, Li-Fan; Lin, Jyh-Ling; Chin, Yuan-Lung; Sun, Tai-Ping
2013-01-01
The purpose of this study was to develop novel nanoscale biosensors using titania nanotubes (TNTs) made by anodization. Titania nanotubes were produced on pure titanium sheets by anodization at room temperature. In this research, the electrolyte composition ethylene glycol 250 mL/NH4F 1.5 g/DI water 20 mL was found to produce the best titania nanotubes array films for application in amperometric biosensors. The amperometric results exhibit an excellent linearity for uric acid (UA) concentrations in the range between 2 and 14 mg/dL, with 23.3 (μA·cm−2)·(mg/dL)−1 UA sensitivity, and a correlation coefficient of 0.993. The glucose biosensor presented a good linear relationship in the lower glucose concentration range between 50 and 125 mg/dL, and the corresponding sensitivity was approximately 249.6 (μA·cm−2)·(100 mg/dL)−1 glucose, with a correlation coefficient of 0.973. PMID:24152934
Relations among low ionosphere parameters and high frequency radio wave absorption
NASA Technical Reports Server (NTRS)
Cipriano, J. P.
1973-01-01
Charged particle conductivities measured in the very low ionosphere at White Sands Missile Range, New Mexico, and Wallops Island, Virginia, are compared with atmospheric parameters and high frequency radio wave absorption measurements. Charged particle densities are derived from the conductivity data. Between 33 and 58 km, positive conductivity correlated well with neutral atmospheric temperature, with temperature coefficients as large as 4.6%/deg K. Good correlations were also found between HF radio wave absorption and negative conductivity at altitudes as low as 53 km, indicating that the day-to-day absorption variations were principally due to variations in electron loss rate.
Development and validation of PediaTrac™: A web-based tool to track developing infants.
Lajiness-O'Neill, Renée; Brooks, Judith; Lukomski, Angela; Schilling, Stephen; Huth-Bocks, Alissa; Warschausky, Seth; Flores, Ana-Mercedes; Swick, Casey; Nyman, Tristin; Andersen, Tiffany; Morris, Natalie; Schmitt, Thomas A; Bell-Smith, Jennifer; Moir, Barbara; Hodges, Elise K; Lyddy, James E
2018-02-01
PediaTrac™, a 363-item web-based tool to track infant development, administered in modules of ∼40-items per sampling period, newborn (NB), 2--, 4--, 6--, 9-- and 12--months was validated. Caregivers answered demographic, medical, and environmental questions, and questions covering the sensorimotor, feeding/eating, sleep, speech/language, cognition, social-emotional, and attachment domains. Expert Panel Reviews and Cognitive Interviews (CI) were conducted to validate the item bank. Classical Test Theory (CTT) and Item Response Theory (IRT) methods were employed to examine the dimensionality and psychometric properties of PediaTrac with pooled longitudinal and cross-sectional cohorts (N = 132). Intraclass correlation coefficients (ICC) for the Expert Panel Review revealed moderate agreement at 6 -months and good reliability at other sampling periods. ICC estimates for CI revealed moderate reliability regarding clarity of the items at NB and 4 months, good reliability at 2--, 9-- and 12--months and excellent reliability at 6 -months. CTT revealed good coefficient alpha estimates (α ≥ 0.77 for five of the six ages) for the Social-Emotional/Communication, Attachment (α ≥ 0.89 for all ages), and Sensorimotor (α ≥ 0.75 at 6-months) domains, revealing the need for better targeting of sensorimotor items. IRT modeling revealed good reliability (r = 0.85-0.95) for three distinct domains (Feeding/Eating, Social-Emotional/Communication and Attachment) and four subdomains (Feeding Breast/Formula, Feeding Solid Food, Social-Emotional Information Processing, Communication/Cognition). Convergent and discriminant construct validity were demonstrated between our IRT-modeled domains and constructs derived from existing developmental, behavioral and caregiver measures. Our Attachment domain was significantly correlated with existing measures at the NB and 2-month periods, while the Social-Emotional/Communication domain was highly correlated with similar constructs at the 6-, 9- and 12-month periods. PediaTrac has potential for producing novel and effective estimates of infant development via the Sensorimotor, Feeding/Eating, Social-Emotional/Communication and Attachment domains. Copyright © 2018 Elsevier Inc. All rights reserved.
Moriya, Shingo; Notani, Kenji; Murata, Ayumi; Inoue, Nobuo; Miura, Hiroko
2014-12-01
The aim of this study was to assess relationships among perceived chewing ability, dentition status, muscle strength and balance in community-dwelling older adults using analysis of moment structures (Amos). Physical performance parameters such as muscle strength and balance can predict the future onset of disabilities in activities of daily living among older adults. In this context, elucidation of the relationships among oral conditions and physical performance parameters is necessary. Data on occlusal contact patterns of natural teeth (OPNT), self-assessed masticatory ability (mastication), body mass index (BMI), handgrip strength (HG) and one-leg standing time with eyes open (OLST) were collected from 501 independently living adults aged 65-74 years. The relationships among these parameters were analysed using Spearman's rank correlation coefficients and Amos. Subjects of both genders showed significant correlations among OPNT, mastication, HG and OLST, evaluated using Spearman's rank correlation coefficients. For each Amos model, the goodness-of-fit statistic indicated a good level of fit. In both men and women, OPNT was significantly related to mastication, and mastication was related to HG but not to OLST. OPNT was related to neither HG nor OLST in women and was related to OLST but not HG in men. The findings observed in this study present a possible importance of dental status and perceived chewing ability for the onset of disability by influencing physical performance in community-dwelling older adults. © 2012 The Gerodontology Society and John Wiley & Sons A/S.
Development of the Psychiatric Nurse Job Stressor Scale (PNJSS).
Yada, Hironori; Abe, Hiroshi; Funakoshi, Yayoi; Omori, Hisamitsu; Matsuo, Hisae; Ishida, Yasushi; Katoh, Takahiko
2011-10-01
The aim of the present study was to develop a tool, the Psychiatric Nurse Job Stressor Scale (PNJSS), for measuring the stress of psychiatric nurses, and to evaluate the reliability and validity of the PNJSS. A total of 302 psychiatric nurses completed all the questions in an early version of the PNJSS, which was composed of 63 items and is based on past literature of psychiatric nurses' stress. A total of 22 items from four factors, 'Psychiatric Nursing Ability', 'Attitude of Patients', 'Attitude Toward Nursing' and 'Communication', were extracted in exploratory factor analysis. With regard to scale reliability, the item-scale correlation coefficient was r = 0.265-0.570 (P < 0.01), the Cronbach alpha coefficient was 0.675-0.869, and the test-retest correlation coefficient was r = 0.439-0.771 (P < 0.01). With regard to scale validity, the convergent validity of the 'job stressor' scale was r = 0.172-0.420 (P < 0.01), and the predictive validity of the 'job reaction' scale was r = 0.201-0.453 (P < 0.01). The compatibility of the factor model to the data was 1.750 (χ(2) /d.f., 343.189/196, P < 0.01), the goodness of fit index was 0.910, the adjusted goodness of fit index was 0.883, the comparative fit index was 0.924, and the root mean square error of approximation was 0.050. The PNJSS has sufficient reliability and validity as a four-factor structure containing 22 items, and is valid as a tool for evaluating psychiatric nurse job stressors. © 2011 The Authors. Psychiatry and Clinical Neurosciences © 2011 Japanese Society of Psychiatry and Neurology.
Reliability and validity of the Chinese mandarin version of PedsQL™ 3.0 transplant module.
Chang, Ying; Luo, Yanhui; Zhou, Yuchen; Wang, Ruixin; Song, Na; Zhu, Guanghua; Wang, Bin; Qin, Maoquan; Yang, Jun; Sun, Yuan; Li, Chunfu; Zhou, Xuan
2016-10-05
Long-term health-related quality of life (HRQoL) of pediatric patients after hematopoietic stem cell transplantation (HSCT) is increasingly studied worldwide. However, few studies have been performed in China, where no uniform scale is available; the PedsQL™ Cancer Module 3.0 Chinese Mandarin version has been used to evaluate HRQoL of patients after HSCT in China. This study aimed to assess the reliability and validity of the Chinese Mandarin version of PedsQL™ 3.0 Transplant Module. Patients between 2 and 18 years old, who underwent HSCT from January 2006 to June 2014, were recruited in Beijing Children's Hospital affiliated to Capital Medical University, the First Affiliated Hospital of Southern Medical University and Beijing Daopei Hospital. 207 parent reports and 182 child self-reports of the PedsQL™ 3.0 Transplant Module Chinese Mandarin version were assigned, of which 362 were returned. No missing item response was observed in the returned reports. Cronbach's alpha coefficient exceeded 0.7 in total scale and every dimension. The intraclass correlation coefficient exceeded 0.8 in all dimensions of child self-reports and parent reports. Spearman's rank correlation coefficients of items and their respective dimensions were 0.6-0.94 in parent reports, and 0.62-0.93 in child self-reports, while a weak association was found between the items and other dimensions. Exploratory factor analysis indicated a good extraction effect, and construct validity of the scale was >60 %. The Chinese Mandarin version of PedsQL™ 3.0 Transplant Module has good feasibility, reliability and validity. Its use may help improve the HRQoL of children after HSCT in China.
Ruddock, Alan D; Tew, Garry A; Purvis, Alison J
2014-03-01
Ingestible telemetry pill systems are being increasingly used to assess the intestinal temperature during exercise in hot environments. The purpose of this investigation was to assess the interday reliability of intestinal temperature during an exercise-heat challenge. Intestinal temperature was recorded as 12 physically active men (25 ± 4 years, stature 181.7 ± 7.0 cm, body mass 81.1 ± 10.6 kg) performed two 60-minute bouts of recumbent cycling (50% of peak aerobic power [watts]) in an environmental chamber set at 35° C 50% relative humidity 3-10 days apart. A range of statistics were used to calculate the reliability, including a paired t-test, 95% limits of agreement (LOA), coefficient of variation (CV), standard error of measurement (SEM), Pearson's correlation coefficient (r), intraclass correlation coefficient (ICC), and Cohen's d. Statistical significance was set at p ≤ 0.05. The method indicated a good overall reliability (LOA = ± 0.61° C, CV = 0.58%, SEM = 0.12° C, Cohen's d = 0.12, r = 0.84, ICC = 0.84). Analysis revealed a statistically significant (p = 0.02) mean systematic bias of -0.07 ± 0.31° C, and the investigation of the Bland-Altman plot suggested the presence of heteroscedasticity. Further analysis revealed the minimum "likely" change in intestinal temperature to be 0.34° C. Although the method demonstrates a good reliability, researchers should be aware of heteroscedasticity. Changes in intestinal temperature >0.34° C as a result of exercise or an intervention in a hot environment are likely changes and less influenced by error associated with the method.
Borowitz, Drucy; Lin, Rong; Baker, Susan S
2007-02-01
Two enzyme-linked immunosorbent assay methodologies are used to detect pancreatic insufficiency: monoclonal and polyclonal. We sought to compare these assays in patients with cystic fibrosis and to correlate these with the coefficient of fat absorption (CFA). As part of a larger study, subjects had stool elastase measured by both methods while taking exogenous enzymes. Subjects subsequently stopped enzymes and had a fecal fat balance study performed; the CFA was then calculated. One hundred twenty-four subjects participated in this substudy. The median values for the monoclonal and polyclonal assays were 0.3 and 22.75 microg/g, respectively. The correlation coefficient between the 2 tests was 0.86 (P < 0.0001). The correlation coefficients between CFA and the monoclonal and polyclonal assays were 0.24 (P = 0.006) and 0.10 (P = 0.27), respectively. If the criterion standard definition of pancreatic insufficiency was set at a CFA < 90% and the test definition of pancreatic insufficiency was set at <100 microg/g, then the monoclonal and polyclonal assay positive predictive values were 97.6% (120 of 123) and 97.4% (111 of 114), respectively. The positive predictive value of both monoclonal and polyclonal fecal elastase in patients with cystic fibrosis is extremely good; however, correlation of either test with CFA was poor. The median value for the polyclonal elastase assay is higher than for the monoclonal assay, which could potentially lead to lower sensitivity of the polyclonal assay at lower cutpoints for the monoclonal assay is used.
Park, Jong Cook; Kim, Kwang Sig
2012-03-01
The reliability of test is determined by each items' characteristics. Item analysis is achieved by classical test theory and item response theory. The purpose of the study was to compare the discrimination indices with item response theory using the Rasch model. Thirty-one 4th-year medical school students participated in the clinical course written examination, which included 22 A-type items and 3 R-type items. Point biserial correlation coefficient (C(pbs)) was compared to method of extreme group (D), biserial correlation coefficient (C(bs)), item-total correlation coefficient (C(it)), and corrected item-total correlation coeffcient (C(cit)). Rasch model was applied to estimate item difficulty and examinee's ability and to calculate item fit statistics using joint maximum likelihood. Explanatory power (r2) of Cpbs is decreased in the following order: C(cit) (1.00), C(it) (0.99), C(bs) (0.94), and D (0.45). The ranges of difficulty logit and standard error and ability logit and standard error were -0.82 to 0.80 and 0.37 to 0.76, -3.69 to 3.19 and 0.45 to 1.03, respectively. Item 9 and 23 have outfit > or =1.3. Student 1, 5, 7, 18, 26, 30, and 32 have fit > or =1.3. C(pbs), C(cit), and C(it) are good discrimination parameters. Rasch model can estimate item difficulty parameter and examinee's ability parameter with standard error. The fit statistics can identify bad items and unpredictable examinee's responses.
An eight-legged tactile sensor to estimate coefficient of static friction.
Wei Chen; Rodpongpun, Sura; Luo, William; Isaacson, Nathan; Kark, Lauren; Khamis, Heba; Redmond, Stephen J
2015-08-01
It is well known that a tangential force larger than the maximum static friction force is required to initiate the sliding motion between two objects, which is governed by a material constant called the coefficient of static friction. Therefore, knowing the coefficient of static friction is of great importance for robot grippers which wish to maintain a stable and precise grip on an object during various manipulation tasks. Importantly, it is most useful if grippers can estimate the coefficient of static friction without having to explicitly explore the object first, such as lifting the object and reducing the grip force until it slips. A novel eight-legged sensor, based on simplified theoretical principles of friction is presented here to estimate the coefficient of static friction between a planar surface and the prototype sensor. Each of the sensor's eight legs are straight and rigid, and oriented at a specified angle with respect to the vertical, allowing it to estimate one of five ranges (5 = 8/2 + 1) that the coefficient of static friction can occupy. The coefficient of friction can be estimated by determining whether the legs have slipped or not when pressed against a surface. The coefficients of static friction between the sensor and five different materials were estimated and compared to a measurement from traditional methods. A least-squares linear fit of the sensor estimated coefficient showed good correlation with the reference coefficient with a gradient close to one and an r(2) value greater than 0.9.
Validation of the King's Sarcoidosis Questionnaire (KSQ) in a Dutch sarcoidosis population.
Van Manen, Mirjam J G; Wapenaar, Monique; Strookappe, Bert; Drent, Marjolein; Elfferich, Marjon; de Vries, Jolanda; Gosker, Harry R; Birring, Surinder S; Patel, Amit S; van den Toorn, Leon; van den Blink, Bernt; Boomars, Karin; Hoitsma, Elske; Wijsenbeek, Marlies S
2016-03-29
The King's Sarcoidosis Questionnaire (KSQ) is a brief questionnaire assessing health status using five modules (General Health Status, Lung, Eyes, Skin, Medication) in patients with sarcoidosis. The KSQ was only validated in one English sarcoidosis cohort. The aim of this study was to validate the KSQ in a Dutch sarcoidosis population. The KSQ was translated according to international guidelines and tested in interviews with patients. Consecutive outpatients completed multiple questionnaires twice, two weeks apart. Construct validity, internal consistency and repeatability were determined. Of the 98 patients included 85 had lung, 22 skin and 24 eye disease. There was good construct validity of the KSQ General Health Status module against the World Health Organization Quality of Life-BREF questionnaire. The Medication module correlated weak to moderate with most questionnaires. The correlations with organ-specific questionnaires varied from strong for Eyes (r=0.75), Skin (r=-0.62) to moderate for Lung (r=-0.45 with MRC breathlessness scale). Internal consistency was good for all KSQ modules (Cronbach's α 0.72-0.93). Intraclass correlation coefficients (0.70-0.90) and Bland-Altman plots showed good repeatability of the KSQ. The Dutch KSQ is the first translation of the English KSQ, validated in a Dutch sarcoidosis population.
Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T
2001-09-01
Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.
Image compression using quad-tree coding with morphological dilation
NASA Astrophysics Data System (ADS)
Wu, Jiaji; Jiang, Weiwei; Jiao, Licheng; Wang, Lei
2007-11-01
In this paper, we propose a new algorithm which integrates morphological dilation operation to quad-tree coding, the purpose of doing this is to compensate each other's drawback by using quad-tree coding and morphological dilation operation respectively. New algorithm can not only quickly find the seed significant coefficient of dilation but also break the limit of block boundary of quad-tree coding. We also make a full use of both within-subband and cross-subband correlation to avoid the expensive cost of representing insignificant coefficients. Experimental results show that our algorithm outperforms SPECK and SPIHT. Without using any arithmetic coding, our algorithm can achieve good performance with low computational cost and it's more suitable to mobile devices or scenarios with a strict real-time requirement.
Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah
2015-01-01
Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations. PMID:26509265
Modified Regression Correlation Coefficient for Poisson Regression Model
NASA Astrophysics Data System (ADS)
Kaengthong, Nattacha; Domthong, Uthumporn
2017-09-01
This study gives attention to indicators in predictive power of the Generalized Linear Model (GLM) which are widely used; however, often having some restrictions. We are interested in regression correlation coefficient for a Poisson regression model. This is a measure of predictive power, and defined by the relationship between the dependent variable (Y) and the expected value of the dependent variable given the independent variables [E(Y|X)] for the Poisson regression model. The dependent variable is distributed as Poisson. The purpose of this research was modifying regression correlation coefficient for Poisson regression model. We also compare the proposed modified regression correlation coefficient with the traditional regression correlation coefficient in the case of two or more independent variables, and having multicollinearity in independent variables. The result shows that the proposed regression correlation coefficient is better than the traditional regression correlation coefficient based on Bias and the Root Mean Square Error (RMSE).
The reliability of the Adelaide in-shoe foot model.
Bishop, Chris; Hillier, Susan; Thewlis, Dominic
2017-07-01
Understanding the biomechanics of the foot is essential for many areas of research and clinical practice such as orthotic interventions and footwear development. Despite the widespread attention paid to the biomechanics of the foot during gait, what largely remains unknown is how the foot moves inside the shoe. This study investigated the reliability of the Adelaide In-Shoe Foot Model, which was designed to quantify in-shoe foot kinematics and kinetics during walking. Intra-rater reliability was assessed in 30 participants over five walking trials whilst wearing shoes during two data collection sessions, separated by one week. Sufficient reliability for use was interpreted as a coefficient of multiple correlation and intra-class correlation coefficient of >0.61. Inter-rater reliability was investigated separately in a second sample of 10 adults by two researchers with experience in applying markers for the purpose of motion analysis. The results indicated good consistency in waveform estimation for most kinematic and kinetic data, as well as good inter-and intra-rater reliability. The exception is the peak medial ground reaction force, the minimum abduction angle and the peak abduction/adduction external hindfoot joint moments which resulted in less than acceptable repeatability. Based on our results, the Adelaide in-shoe foot model can be used with confidence for 24 commonly measured biomechanical variables during shod walking. Copyright © 2017 Elsevier B.V. All rights reserved.
Development of the Assessment of Belief Conflict in Relationship-14 (ABCR-14).
Kyougoku, Makoto; Teraoka, Mutsumi; Masuda, Noriko; Ooura, Mariko; Abe, Yasushi
2015-01-01
Nurses and other healthcare workers frequently experience belief conflict, one of the most important, new stress-related problems in both academic and clinical fields. In this study, using a sample of 1,683 nursing practitioners, we developed The Assessment of Belief Conflict in Relationship-14 (ABCR-14), a new scale that assesses belief conflict in the healthcare field. Standard psychometric procedures were used to develop and test the scale, including a qualitative framework concept and item-pool development, item reduction, and scale development. We analyzed the psychometric properties of ABCR-14 according to entropy, polyserial correlation coefficient, exploratory factor analysis, confirmatory factor analysis, average variance extracted, Cronbach's alpha, Pearson product-moment correlation coefficient, and multidimensional item response theory (MIRT). The results of the analysis supported a three-factor model consisting of 14 items. The validity and reliability of ABCR-14 was suggested by evidence from high construct validity, structural validity, hypothesis testing, internal consistency reliability, and concurrent validity. The result of the MIRT offered strong support for good item response of item slope parameters and difficulty parameters. However, the ABCR-14 Likert scale might need to be explored from the MIRT point of view. Yet, as mentioned above, there is sufficient evidence to support that ABCR-14 has high validity and reliability. The ABCR-14 demonstrates good psychometric properties for nursing belief conflict. Further studies are recommended to confirm its application in clinical practice.
Oh, H K; Yu, M J; Gwon, E M; Koo, J Y; Kim, S G; Koizumi, A
2004-01-01
This paper describes the prediction of flux behavior in an ultrafiltration (UF) membrane system using a Kalman neuro training (KNT) network model. The experimental data was obtained from operating a pilot plant of hollow fiber UF membrane with groundwater for 7 months. The network was trained using operating conditions such as inlet pressure, filtration duration, and feed water quality parameters including turbidity, temperature and UV254. Pre-processing of raw data allowed the normalized input data to be used in sigmoid activation functions. A neural network architecture was structured by modifying the number of hidden layers, neurons and learning iterations. The structure of KNT-neural network with 3 layers and 5 neurons allowed a good prediction of permeate flux by 0.997 of correlation coefficient during the learning phase. Also the validity of the designed model was evaluated with other experimental data not used during the training phase and nonlinear flux behavior was accurately estimated with 0.999 of correlation coefficient and a lower error of prediction in the testing phase. This good flux prediction can provide preliminary criteria in membrane design and set up the proper cleaning cycle in membrane operation. The KNT-artificial neural network is also expected to predict the variation of transmembrane pressure during filtration cycles and can be applied to automation and control of full scale treatment plants.
[Determination of tungsten and cobalt in the air of workplace by ICP-OES].
Zhang, J; Ding, C G; Li, H B; Song, S; Yan, H F
2017-08-20
Objective: To establish the inductively coupled plasma optical emission spectrometry (ICP-OES) method for determination of cobalt and tungsten in the air of workplace. Methods: The cobalt and tungsten were collected by filter membrane and then digested by nitric acid, inductively coupled plasma optical emission spectrometry (ICP-OES) was used for the detection of cobalt and tungsten. Results: The linearity of tungsten was good at the range of 0.01-1 000 μg/ml with a correlation coefficient of 0.999 9, the LOD and LOQ were 0.006 7 μg/ml and 0.022 μg/ml, respectively. The recovery was ranged from 98%-101%, the RSD of intra-and inter-batch precision were 1.1%-3.0% and 2.1%-3.8%, respectively. The linearity of cobalt was good at the range of 0.01-100 μg/ml with a correlation coefficient of 0.999 9, the LOD and LOQ were 0.001 2 μg/ml and 0.044 μg/ml, respectively. The recovery was ranged from 95%-97%, the RSD of intra-and inter-batch precision were 1.1%-2.4% and 1.1%-2.9%, respectively. The sampling efficiency of tungsten and cobalt were higher than 94%. Conclusion: The linear range, sensitivity and precision of the method was suitable for the detection of tungsten and cobalt in the air of workplace.
Breeding maize for resistance to ear rot caused by Fusarium moniliforme.
Hefny, M; Attaa, S; Bayoumi, T; Ammar, S; El-Bramawy, M
2012-01-15
Maize ear rots are among the most important impediments to increased maize production in Egypt. The present research was conducted to estimate combining abilities, heterosis and correlation coefficients for resistance to ear rot disease in seven corn inbred lines and their 21 crosses under field conditions. Results demonstrated that both additive and non-additive gene actions were responsible for the genetic expression of all characters with the preponderance of non-additive actions for days to 50% silking. The parental line L51 was the best combiner for earliness, low infection severity %, high phenols content, short plants and reasonable grain yield, while L101 was good combiner for low ear rot infection only. The cross: L122 x L84, L122 x L101, L51 x L101, L76 x L36, L76 x L84, L36 x L84, L36 x L81 and L36 x L101 which involved one or both parents with good General Combining Ability (GCA) effects expressed useful significant heterosis and Specific Combining Ability (SCA) effects for low infection severity %, high phenol contents, early silking, tall plants and high grain yield. Phenotypic and genotypic correlation coefficients suggest that selection for resistance to ear rot should identify lines with high yielding ability, early silking, tall plants, high phenols content and chitinase activity.
Comparison of Automated Brain Volume Measures obtained with NeuroQuant and FreeSurfer.
Ochs, Alfred L; Ross, David E; Zannoni, Megan D; Abildskov, Tracy J; Bigler, Erin D
2015-01-01
To examine intermethod reliabilities and differences between FreeSurfer and the FDA-cleared congener, NeuroQuant, both fully automated methods for structural brain MRI measurements. MRI scans from 20 normal control subjects, 20 Alzheimer's disease patients, and 20 mild traumatically brain-injured patients were analyzed with NeuroQuant and with FreeSurfer. Intermethod reliability was evaluated. Pairwise correlation coefficients, intraclass correlation coefficients, and effect size differences were computed. NeuroQuant versus FreeSurfer measures showed excellent to good intermethod reliability for the 21 regions evaluated (r: .63 to .99/ICC: .62 to .99/ES: -.33 to 2.08) except for the pallidum (r/ICC/ES = .31/.29/-2.2) and cerebellar white matter (r/ICC/ES = .31/.31/.08). Volumes reported by NeuroQuant were generally larger than those reported by FreeSurfer with the whole brain parenchyma volume reported by NeuroQuant 6.50% larger than the volume reported by FreeSurfer. There was no systematic difference in results between the 3 subgroups. NeuroQuant and FreeSurfer showed good to excellent intermethod reliability in volumetric measurements for all brain regions examined with the only exceptions being the pallidum and cerebellar white matter. This finding was robust for normal individuals, patients with Alzheimer's disease, and patients with mild traumatic brain injury. Copyright © 2015 by the American Society of Neuroimaging.
Anguita, Jaime A; Neifeld, Mark A; Vasic, Bane V
2007-09-10
By means of numerical simulations we analyze the statistical properties of the power fluctuations induced by the incoherent superposition of multiple transmitted laser beams in a terrestrial free-space optical communication link. The measured signals arising from different transmitted optical beams are found to be statistically correlated. This channel correlation increases with receiver aperture and propagation distance. We find a simple scaling rule for the spatial correlation coefficient in terms of the propagation distance and we are able to predict the scintillation reduction in previously reported experiments with good accuracy. We propose an approximation to the probability density function of the received power of a spatially correlated multiple-beam system in terms of the parameters of the single-channel gamma-gamma function. A bit-error-rate evaluation is also presented to demonstrate the improvement of a multibeam system over its single-beam counterpart.
Distance correlation methods for discovering associations in large astrophysical databases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martínez-Gómez, Elizabeth; Richards, Mercedes T.; Richards, Donald St. P., E-mail: elizabeth.martinez@itam.mx, E-mail: mrichards@astro.psu.edu, E-mail: richards@stat.psu.edu
2014-01-20
High-dimensional, large-sample astrophysical databases of galaxy clusters, such as the Chandra Deep Field South COMBO-17 database, provide measurements on many variables for thousands of galaxies and a range of redshifts. Current understanding of galaxy formation and evolution rests sensitively on relationships between different astrophysical variables; hence an ability to detect and verify associations or correlations between variables is important in astrophysical research. In this paper, we apply a recently defined statistical measure called the distance correlation coefficient, which can be used to identify new associations and correlations between astrophysical variables. The distance correlation coefficient applies to variables of any dimension,more » can be used to determine smaller sets of variables that provide equivalent astrophysical information, is zero only when variables are independent, and is capable of detecting nonlinear associations that are undetectable by the classical Pearson correlation coefficient. Hence, the distance correlation coefficient provides more information than the Pearson coefficient. We analyze numerous pairs of variables in the COMBO-17 database with the distance correlation method and with the maximal information coefficient. We show that the Pearson coefficient can be estimated with higher accuracy from the corresponding distance correlation coefficient than from the maximal information coefficient. For given values of the Pearson coefficient, the distance correlation method has a greater ability than the maximal information coefficient to resolve astrophysical data into highly concentrated horseshoe- or V-shapes, which enhances classification and pattern identification. These results are observed over a range of redshifts beyond the local universe and for galaxies from elliptical to spiral.« less
Östling, Gerd; Nilsson, Peter M.
2015-01-01
Introduction Arterial stiffness is an independent risk factor for cardiovascular morbidity and can be assessed by applanation tonometry by measuring pulse wave velocity (PWV) and augmentation index (AIX) by pressure pulse wave analysis (PWA). As an inexpensive and operator independent alternative, photoelectric plethysmography (PPG) has been introduced with analysis of the digital volume pulse wave (DPA) and its second derivatives of wave reflections. Objective The objective was to investigate the repeatability of arterial stiffness parameters measured by digital pulse wave analysis (DPA) and the associations to applanation tonometry parameters. Methods and Results 112 pregnant and non-pregnant individuals of different ages and genders were examined with SphygmoCor arterial wall tonometry and Meridian DPA finger photoplethysmography. Coefficients of repeatability, Bland-Altman plots, intraclass correlation coefficients and correlations to heart rate (HR) and body height were calculated for DPA variables, and the DPA variables were compared to tonometry variables left ventricular ejection time (LVET), PWV and AIX. No DPA variable showed any systematic measurement error or excellent repeatability, but dicrotic index (DI), dicrotic dilatation index (DDI), cardiac ejection elasticity index (EEI), aging index (AI) and second derivatives of the crude pulse wave curve, b/a and e/a, showed good repeatability. Overall, the correlations to AIX were better than to PWV, with correlations coefficients >0.70 for EEI, AI and b/a. Considering the level of repeatability and the correlations to tonometry, the overall best DPA parameters were EEI, AI and b/a. The two pansystolic time parameters, ejection time compensated (ETc) by DPA and LVET by tonometry, showed a significant but weak correlation. Conclusion For estimation of the LV function, ETc, EEI and b/a are suitable, for large artery stiffness EEI, and for small arteries DI and DDI. The only global parameter, AI, showed a high repeatability and the overall best correlations with AIX and PWV. PMID:26291079
Clustering Coefficients for Correlation Networks.
Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu
2018-01-01
Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties.
Clustering Coefficients for Correlation Networks
Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu
2018-01-01
Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties. PMID:29599714
Zhao, Yu Xi; Xie, Ping; Sang, Yan Fang; Wu, Zi Yi
2018-04-01
Hydrological process evaluation is temporal dependent. Hydrological time series including dependence components do not meet the data consistency assumption for hydrological computation. Both of those factors cause great difficulty for water researches. Given the existence of hydrological dependence variability, we proposed a correlationcoefficient-based method for significance evaluation of hydrological dependence based on auto-regression model. By calculating the correlation coefficient between the original series and its dependence component and selecting reasonable thresholds of correlation coefficient, this method divided significance degree of dependence into no variability, weak variability, mid variability, strong variability, and drastic variability. By deducing the relationship between correlation coefficient and auto-correlation coefficient in each order of series, we found that the correlation coefficient was mainly determined by the magnitude of auto-correlation coefficient from the 1 order to p order, which clarified the theoretical basis of this method. With the first-order and second-order auto-regression models as examples, the reasonability of the deduced formula was verified through Monte-Carlo experiments to classify the relationship between correlation coefficient and auto-correlation coefficient. This method was used to analyze three observed hydrological time series. The results indicated the coexistence of stochastic and dependence characteristics in hydrological process.
Synkinesis assessment in facial palsy: validation of the Dutch Synkinesis Assessment Questionnaire.
Kleiss, Ingrid J; Beurskens, Carien H G; Stalmeier, Peep F M; Ingels, Koen J A O; Marres, Henri A M
2016-06-01
The objective of this study is to validate an existing health-related quality of life questionnaire for patients with synkinesis in facial palsy for implementation in the Dutch language and culture. The Synkinesis Assessment Questionnaire was translated into the Dutch language using a forward-backward translation method. A pilot test with the translated questionnaire was performed in 10 patients with facial palsy and 10 normal subjects. Finally, cross-cultural adaption was accomplished at our outpatient clinic for facial palsy. Analyses for internal consistency, test-retest reliability, and construct validity were performed. Sixty-six patients completed the Dutch Synkinesis Assessment Questionnaire and the Dutch Facial Disability Index. Cronbach's α, representing internal consistency, was 0.80. Test-retest reliability was 0.53 (Spearman's correlation coefficient, P < 0.01). Correlations with the House-Brackmann score, Sunnybrook score, Facial Disability Index physical function, and social/well-being function were -0.29, 0.20, -0.29, and -0.32, respectively. Correlation with the Sunnybrook synkinesis subscore was 0.50 (Spearman's correlation coefficient). The Dutch Synkinesis Assessment Questionnaire shows good psychometric values and can be implemented in the management of Dutch-speaking patients with facial palsy and synkinesis in the Netherlands. Translation of the instrument into other languages may lead to widespread use, making evaluation, and comparison possible among different providers.
Krüger, Jan-Christopher; Meves, Saskia H; Kara, Kaffer; Mügge, Andreas; Neubauer, Horst
2014-10-01
Several platelet function test systems exist for the evaluation of the platelet inhibitory effect in patients on P2Y12 inhibitors and/or acetylsalicylic acid (ASA, aspirin) therapy. Studies comparing different available assays found only a poor correlation. The objective of the present study was to evaluate the correlation and agreement between single electrode (SEA) and multiple electrode (MEA) aggregometry. In whole blood arachidonic acid (AA) and adenosine diphosphate (ADP)-induced platelet aggregation was measured simultaneously using SEA (Chrono-Log) and MEA (Multiplate). We analyzed a total of 226 measurements taken from 58 patients on single ASA therapy or dual antiplatelet therapy with ASA and a thienopyridine. A cut-off value for clopidogrel/prasugrel high on-treatment platelet reactivity (HPR) of > 47 units (U) was chosen for MEA testing using hirudin and > 5 Ohm for SEA with citrate anticoagulated blood samples. The respective cut-off values for ASA HPR were > 30 U for the MEA assay and > 1 Ohm for SEA testing. There was a good correlation of the prevalence of thienopyridine-HPR in both whole blood assays (Spearman rank correlation coefficient r = 0.698) and a good inter-rate accordance (Cohen's Kappa statistic κ = 0.648). For AA-induced aggregation, the correlation of the results obtained was significant (r = 0.536; p < 0.001) and detecting ASA-HPR revealed a moderate (κ = 0.482) correlation between both impedance aggregometry assays. Platelet function testing using SEA and MEA provided both good accordance and correlation and therefore study results obtained by these two assays similarly enabled the detection of HPR of thienopyridine (and ASA) therapy.
Estimation of the biserial correlation and its sampling variance for use in meta-analysis.
Jacobs, Perke; Viechtbauer, Wolfgang
2017-06-01
Meta-analyses are often used to synthesize the findings of studies examining the correlational relationship between two continuous variables. When only dichotomous measurements are available for one of the two variables, the biserial correlation coefficient can be used to estimate the product-moment correlation between the two underlying continuous variables. Unlike the point-biserial correlation coefficient, biserial correlation coefficients can therefore be integrated with product-moment correlation coefficients in the same meta-analysis. The present article describes the estimation of the biserial correlation coefficient for meta-analytic purposes and reports simulation results comparing different methods for estimating the coefficient's sampling variance. The findings indicate that commonly employed methods yield inconsistent estimates of the sampling variance across a broad range of research situations. In contrast, consistent estimates can be obtained using two methods that appear to be unknown in the meta-analytic literature. A variance-stabilizing transformation for the biserial correlation coefficient is described that allows for the construction of confidence intervals for individual coefficients with close to nominal coverage probabilities in most of the examined conditions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Lim, Kok Bin; Ho, Henry; Foo, Keong Tatt; Wong, Michael Yuet Chen; Fook-Chong, Stephanie
2006-12-01
The aims of this study were to define the relationship between intravesical prostatic protrusion (IPP), prostate-specific antigen (PSA) and prostate volume (PV) and to determine which one of them is the best predictor of bladder outlet obstruction (BOO) due to benign prostatic enlargement. A prospective study of 114 male patients older than 50 years examined between November 2001 and 2002 was performed. They were evaluated with digital rectal examination, International Prostate Symptoms Score, PSA, uroflowmetry, postvoid residual urine measurement, IPP and PV using transabdominal ultrasound scan. Statistical analysis included scatter plot with Spearman's correlation coefficients and nominal logistic regression Prostate volume, IPP and PSA showed parallel correlation. Although all three indices had good correlation with BOO index, IPP was the best. The Spearman rho correlation coefficients were 0.314, 0.408 and 0.507 for PV, PSA and IPP, respectively. Using receiver-operator characteristic curves, the areas under the curve for PV, PSA and IPP were 0.637, 0.703 and 0.772, respectively. The positive predictive values of PV, PSA and IPP were 65%, 68% and 72%, respectively. Using a nominal regression model, IPP remained the most significant independent index to determine BOO. All three non-invasive indices correlate with one another. The study showed that IPP is a better predictor for BOO than PSA or PV.
Tang, Meiqiong; Hu, Ping; Huang, Shigui; Zheng, Qiang; Yu, Hao; He, Yun
2016-11-01
The primary objective of the present study was to develop extended-release matrix formulations of apremilast for the oral delivery and to study their in vitro and in vivo correlation. Five extended-release formulations containing hydroxypropylmethylcellulose (HPMC) as the retarding excipient with different release rate of apremilast were prepared. Dissolution tests of all the formulated tablets were performed in water, pH 4.0 and 6.8 buffer solutions. The in vitro release kinetics was studied and supported by Korsmeyer-Peppas's equation as it presented highest values of correlation coefficients (r 2 up to 0.966). Among all formulated tablets, F2 (HPMC 25%) and F4 (HPMC 35%) were selected to perform an in vivo study in beagle dogs to obtain various pharmacokinetic parameters, i.e., peak plasma concentration (C max ), time to peak plasma concentration (t max ), area under the plasma-concentration vs. time curve (AUC). Higher t max and t 1/2 , lower C max and elimination coefficient (K e ) were observed for both extended formulations compared to marketed immediate-release products (Otezla ® ). Level A in vitro-in vivo correlations were created with the help of Wagner-Nelson and numeric deconvolution methods. Both formulations showed good in vitro-in vivo correlations whose accuracies were further verified by an internal validation.
Lleó-Pérez, A; Ortuño-Soto, A; Rahhal, M S; Martínez-Soriano, F; Sanchis-Gimeno, J A
2004-01-01
To evaluate quantitatively the intraobserver reproducibility of measurements of the retinal nerve fiber layer (RNFL) in healthy subjects and an ocular hypertensive population using two nerve fiber analyzers. Sixty eyes of normal (n=30) and ocular hypertensive subjects (n=30) were consecutively recruited for this study and underwent a complete ophthalmologic examination and achromatic automated perimetry. RNFL were measured using scanning laser polarimeter (GDx-VCC) and optical coherence tomography (OCT Model 3000). Reproducibility of the RNFL measurements obtained with both nerve fiber analyzers were compared using the coefficient of variation. In both groups the authors found fair correlations between the two methods in all ratio and thickness parameters. The mean coefficient of variation for measurement of the variables ranged from 2.24% to 13.12% for GDx-VCC, and from 5.01% to 9.24% for OCT Model 3000. The authors could not detect any significant differences between healthy and ocular hypertensive eyes, although in normal eyes the correlations improved slightly. Nevertheless, the test-retest correlation was slightly better for GDx-VCC than for OCT Model 3000 (5.55% and 7.11%, respectively). Retinal mapping software of both nerve fiber analyzers allows reproducible measurement of RNFL in both healthy subjects and ocular hypertensive eyes, and shows fair correlations and good intraobserver reproducibility. However, in our study, GDx showed a better test-retest correlation.
Ferraioli, Giovanna; Tinelli, Carmine; Lissandrin, Raffaella; Zicchetti, Mabel; Faliva, Milena; Perna, Simone; Perani, Guido; Alessandrino, Francesco; Calliada, Fabrizio; Rondanelli, Mariangela; Filice, Carlo
2015-03-01
The aim of this study was to assess the clinical relevance of the controlled attenuation parameter (CAP) by analyzing the correlations between CAP and indirect indices of liver steatosis in obese or overweight individuals. Consecutive participants were prospectively enrolled. BMI, waist circumference, hepatic steatosis index, fatty liver index, percent fat mass and regional fat masses as assessed by dual-energy X-ray absorptiometry (DXA), fat signal fraction as assessed by MRI, and CAP were obtained. Pearson's r coefficient was used to test the correlation between two study variables. A total of 88 individuals were studied. They included 31 men [age, 50.4 years (12.9 years); BMI, 30.7 kg/m (4.8 kg/m)] and 57 women [age, 49.0 years (12.6 years); BMI, 31.4 kg/m (5.6 kg/m)]. DXA, anthropometric parameters, and fatty liver index were moderately correlated with CAP in men. In women, there was a moderate correlation of CAP with the hepatic steatosis index and anthropometric parameters and only a slight or fair correlation of CAP with DXA parameters. CAP and fat signal fraction showed a good correlation (r=0.65 in men, P=0.002; r=0.68 in women, P=0.0009). Measurement of CAP is a reliable method for noninvasive assessment of liver steatosis, showing a correlation with other indirect markers of central obesity and a good correlation with MRI results.
Bengi, Göksel; Yalçın, Mustafa; Akpınar, Hale; Keskinoğlu, Pembe; Ellidokuz, Hülya
2015-07-01
There are few specific evaluation forms for evaluating the quality of life among patients with chronic constipation. Our study aimed to determine the validity and reliability of the translated Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire for the Turkish population because evidence of its reliability and validity is required to justify its use in other studies and clinical practice. This study included 154 patients with constipation who were treated at the Department of Gastroenterology, Dokuz Eylül University Hospital between January and June 2012. The translated PAC-QOL questionnaire was completed by patients at the clinic and also at a 2-week follow-up to test its reliability. Cronbach's alpha coefficient (internal consistency) was 0.91 (good) for the translated PAC-QOL questionnaire. Time validity was evaluated using the intraclass correlation coefficient (ICC) method, and the ICC value for all questions was confirmed as 0.68 at the 2-week follow-up. The validity of the tool in the study group was evaluated using factor analysis, and the results were highly significant (Kaiser-Meyer-Olkin value: 0.857; Bartlett's test: p=0.001). Questions were categorized according to six factors based on the factor analysis, and these factors explained 65.1% of the total variation. For hypothesis verification of the tool, the correlation coefficient for PAC-QOL and PAC Symptoms (PAC-SYM) was r=0.577 (p<0.001), whereas the correlation coefficient for PAC-QOL and constipation severity score was r=0.457 (p<0.001). The PAC-QOL questionnaire was reliable, although not valid because of the limited sample group.
Estimation of the simple correlation coefficient.
Shieh, Gwowen
2010-11-01
This article investigates some unfamiliar properties of the Pearson product-moment correlation coefficient for the estimation of simple correlation coefficient. Although Pearson's r is biased, except for limited situations, and the minimum variance unbiased estimator has been proposed in the literature, researchers routinely employ the sample correlation coefficient in their practical applications, because of its simplicity and popularity. In order to support such practice, this study examines the mean squared errors of r and several prominent formulas. The results reveal specific situations in which the sample correlation coefficient performs better than the unbiased and nearly unbiased estimators, facilitating recommendation of r as an effect size index for the strength of linear association between two variables. In addition, related issues of estimating the squared simple correlation coefficient are also considered.
Structure dependence of the rate coefficients of hydroxyl radical+aromatic molecule reaction
NASA Astrophysics Data System (ADS)
Wojnárovits, László; Takács, Erzsébet
2013-06-01
The rate coefficients of hydroxyl radical addition to the rings of simple aromatic molecules (kOH) were evaluated based on the literature data. By analyzing the methods of kOH determination and the data obtained the most probable values were selected for the kOH's of individual compounds and thereby the most reliable dataset was created for monosubstituted aromatics and p-substituted phenols. For these compounds the rate coefficients fall in a narrow range between 2×109 mol-1 dm3 s-1 and 1×1010 mol-1 dm3 s-1. Although the values show some regular trend with the electron donating/withdrawing nature of the substituent, the log kOH-σp Hammett substituent constant plots do not give straight lines because these high kOH's are controlled by both, the chemical reactivity and the diffusion. However, the logarithms of the rate coefficients of the chemical reactivity controlled reactions (kchem), are calculated by the equation 1/kOH=1/kchem+1/kdiff, and accepting for the diffusion controlled rate coefficient kdiff=1.1×1010 mol-1 dm3 s-1, show good linear correlation with σp.
Estimating consumer familiarity with health terminology: a context-based approach.
Zeng-Treitler, Qing; Goryachev, Sergey; Tse, Tony; Keselman, Alla; Boxwala, Aziz
2008-01-01
Effective health communication is often hindered by a "vocabulary gap" between language familiar to consumers and jargon used in medical practice and research. To present health information to consumers in a comprehensible fashion, we need to develop a mechanism to quantify health terms as being more likely or less likely to be understood by typical members of the lay public. Prior research has used approaches including syllable count, easy word list, and frequency count, all of which have significant limitations. In this article, we present a new method that predicts consumer familiarity using contextual information. The method was applied to a large query log data set and validated using results from two previously conducted consumer surveys. We measured the correlation between the survey result and the context-based prediction, syllable count, frequency count, and log normalized frequency count. The correlation coefficient between the context-based prediction and the survey result was 0.773 (p < 0.001), which was higher than the correlation coefficients between the survey result and the syllable count, frequency count, and log normalized frequency count (p < or = 0.012). The context-based approach provides a good alternative to the existing term familiarity assessment methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nazhan, Salam; Ghassemlooy, Zabih; Busawon, Krishna
2016-01-15
In this paper, the influence of the rotating polarization-preserved optical feedback on the chaos synchronization of a vertical-cavity surface-emitting laser (VCSEL) is investigated experimentally. Two VCSELs' polarization modes (XP) and (YP) are gradually rotated and re-injected back into the VCSEL. The anti-phase dynamics synchronization of the two polarization modes is evaluated using the cross-correlation function. For a fixed optical feedback, a clear relationship is found between the cross-correlation coefficient and the polarization angle θ{sub p}. It is shown that high-quality anti-phase polarization-resolved chaos synchronization is achieved at higher values of θ{sub p}. The maximum value of the cross-correlation coefficient achievedmore » is −0.99 with a zero time delay over a wide range of θ{sub p} beyond 65° with a poor synchronization dynamic at θ{sub p} less than 65°. Furthermore, it is observed that the antiphase irregular oscillation of the XP and YP modes changes with θ{sub p}. VCSEL under the rotating polarization optical feedback can be a good candidate as a chaotic synchronization source for a secure communication system.« less
Vieira, Gisele de Lacerda Chaves; Pagano, Adriana Silvino; Reis, Ilka Afonso; Rodrigues, Júlia Santos Nunes; Torres, Heloísa de Carvalho
2018-01-01
ABSTRACT Objective: to perform the translation, adaptation and validation of the Diabetes Attitudes Scale - third version instrument into Brazilian Portuguese. Methods: methodological study carried out in six stages: initial translation, synthesis of the initial translation, back-translation, evaluation of the translated version by the Committee of Judges (27 Linguists and 29 health professionals), pre-test and validation. The pre-test and validation (test-retest) steps included 22 and 120 health professionals, respectively. The Content Validity Index, the analyses of internal consistency and reproducibility were performed using the R statistical program. Results: in the content validation, the instrument presented good acceptance among the Judges with a mean Content Validity Index of 0.94. The scale presented acceptable internal consistency (Cronbach’s alpha = 0.60), while the correlation of the total score at the test and retest moments was considered high (Polychoric Correlation Coefficient = 0.86). The Intra-class Correlation Coefficient, for the total score, presented a value of 0.65. Conclusion: the Brazilian version of the instrument (Escala de Atitudes dos Profissionais em relação ao Diabetes Mellitus) was considered valid and reliable for application by health professionals in Brazil. PMID:29319739
Bhargava, Dinesh; Karthikeyan, C; Moorthy, N S H N; Trivedi, Piyush
2009-09-01
QSAR study was carried out for a series of piperazinyl phenylalanine derivatives exhibiting VLA-4/VCAM-1 inhibitory activity to find out the structural features responsible for the biological activity. The QSAR study was carried out on V-life Molecular Design Suite software and the derived best QSAR model by partial least square (forward) regression method showed 85.67% variation in biological activity. The statistically significant model with high correlation coefficient (r2=0.85) was selected for further study and the resulted validation parameters of the model, crossed squared correlation coefficient (q2=0.76 and pred_r2=0.42) show the model has good predictive ability. The model showed that the parameters SaaNEindex, SsClcount slogP,and 4PathCount are highly correlated with VLA-4/VCAM-1 inhibitory activity of piperazinyl phenylalanine derivatives. The result of the study suggests that the chlorine atoms in the molecule and fourth order fragmentation patterns in the molecular skeleton favour VLA-4/VCAM-1 inhibition shown by the title compounds whereas lipophilicity and nitrogen bonded to aromatic bond are not conducive for VLA-4/VCAM-1 inhibitory activity.
Validation of MODIS Aerosol Optical Depth Retrievals over a Tropical Urban Site, Pune, India
NASA Technical Reports Server (NTRS)
More, Sanjay; Kuman, P. Pradeep; Gupta, Pawan; Devara, P. C. S.; Aher, G. R.
2011-01-01
In the present paper, MODIS (Terra and Aqua; level 2, collection 5) derived aerosoloptical depths (AODs) are compared with the ground-based measurements obtained from AERONET (level 2.0) and Microtops - II sun-photometer over a tropical urban station, Pune (18 deg 32'N; 73 deg 49'E, 559 m amsl). This is the first ever systematic validation of the MODIS aerosol products over Pune. Analysis of the data indicates that the Terra and Aqua MODIS AOD retrievals at 550 nm have good correlations with the AERONET and Microtops - II sun-photometer AOD measurements. During winter the linear regression correlation coefficients for MODIS products against AERONET measurements are 0.79 for Terra and 0.62 for Aqua; however for premonsoon, the corresponding coefficients are 0.78 and 0.74. Similarly, the linear regression correlation coefficients for Microtops measurements against MODIS products are 0.72 and 0.93 for Terra and Aqua data respectively during winter and are 0.78 and 0.75 during pre-monsoon. On yearly basis in 2008-2009, correlation coefficients for MODIS products against AERONET measurements are 0.80 and 0.78 for Terra and Aqua respectively while the corresponding coefficients are 0.70 and 0.73 during 2009-2010. The regressed intercepts with MODIS vs. AERONET are 0.09 for Terra and 0.05 for Aqua during winter whereas their values are 0.04 and 0.07 during pre-monsoon. However, MODIS AODs are found to underestimate during winter and overestimate during pre-monsoon with respect to AERONET and Microtops measurements having slopes 0.63 (Terra) and 0.74 (Aqua) during winter and 0.97 (Terra) and 0.94 (Aqua) during pre-monsoon. Wavelength dependency of Single Scattering Albedo (SSA) shows presence of absorbing and scattering aerosol particles. For winter, SSA decreases with wavelength with the values 0.86 +/- 0.03 at 440 nm and 0.82 +/- 0.04 at 1020nm. In pre-monsoon, it increases with wavelength (SSA is 0.87 +/- 0.02 at 440nm; and 0.88 +/-0.04 at 1020 nm).
Comparison of Nimbus-7 SMMR and GOES-1 VISSR Atmospheric Liquid Water Content.
NASA Astrophysics Data System (ADS)
Lojou, Jean-Yves; Frouin, Robert; Bernard, René
1991-02-01
Vertically integrated atmospheric liquid water content derived from Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) brightness temperatures and from GOES-1 Visible and Infrared Spin-Scan Radiometer (VISSR) radiances in the visible are compared over the Indian Ocean during MONEX (monsoon experiment). In the retrieval procedure, Wilheit and Chang' algorithm and Stephens' parameterization schemes are applied to the SMMR and VISSR data, respectively. The results indicate that in the 0-100 mg cm2 range of liquid water content considered, the correlation coefficient between the two types of estimates is 0.83 (0.81- 0.85 at the 99 percent confidence level). The Wilheit and Chang algorithm, however, yields values lower than those obtained with Stephens's schemes by 24.5 mg cm2 on the average, and occasionally the SMMR-based values are negative. Alternative algorithms are proposed for use with SMMR data, which eliminate the bias, augment the correlation coefficient, and reduce the rms difference. These algorithms include using the Witheit and Chang formula with modified coefficients (multilinear regression), the Wilheit and Chang formula with the same coefficients but different equivalent atmospheric temperatures for each channel (temperature bias adjustment), and a second-order polynomial in brightness temperatures at 18, 21, and 37 GHz (polynomial development). When applied to a dataset excluded from the regressionn dataset, the multilinear regression algorithm provides the best results, namely a 0.91 correlation coefficient, a 5.2 mg cm2 (residual) difference, and a 2.9 mg cm2 bias. Simply shifting the liquid water content predicted by the Wilheit and Chang algorithm does not yield as good comparison statistics, indicating that the occasional negative values are not due only to a bias. The more accurate SMMR-derived liquid water content allows one to better evaluate cloud transmittance in the solar spectrum, at least in the area and during the period analyzed. Combining this cloud transmittance with a clear sky model would provide ocean surface insulation estimates from SMMR data alone.
Rosales, Roberto S; Martin-Hidalgo, Yolanda; Reboso-Morales, Luis; Atroshi, Isam
2016-03-03
The purpose of this study was to assess the reliability and construct validity of the Spanish version of the 6-item carpal tunnel syndrome (CTS) symptoms scale (CTS-6). In this cross-sectional study 40 patients diagnosed with CTS based on clinical and neurophysiologic criteria, completed the standard Spanish versions of the CTS-6 and the disabilities of the arm, shoulder and hand (QuickDASH) scales on two occasions with a 1-week interval. Internal-consistency reliability was assessed with the Cronbach alpha coefficient and test-retest reliability with the intraclass correlation coefficient, two way random effect model and absolute agreement definition (ICC2,1). Cross-sectional precision was analyzed with the Standard Error of the Measurement (SEM). Longitudinal precision for test-retest reliability coefficient was assessed with the Standard Error of the Measurement difference (SEMdiff) and the Minimal Detectable Change at 95 % confidence level (MDC95). For assessing construct validity it was hypothesized that the CTS-6 would have a strong positive correlation with the QuickDASH, analyzed with the Pearson correlation coefficient (r). The standard Spanish version of the CTS-6 presented a Cronbach alpha of 0.81 with a SEM of 0.3. Test-retest reliability showed an ICC of 0.85 with a SRMdiff of 0.36 and a MDC95 of 0.7. The correlation between CTS-6 and the QuickDASH was concordant with the a priori formulated construct hypothesis (r 0.69) CONCLUSIONS: The standard Spanish version of the 6-item CTS symptoms scale showed good internal consistency, test-retest reliability and construct validity for outcomes assessment in CTS. The CTS-6 will be useful to clinicians and researchers in Spanish speaking parts of the world. The use of standardized outcome measures across countries also will facilitate comparison of research results in carpal tunnel syndrome.
Repeatability of short-duration transient visual evoked potentials in normal subjects.
Tello, Celso; De Moraes, Carlos Gustavo V; Prata, Tiago S; Derr, Peter; Patel, Jayson; Siegfried, John; Liebmann, Jeffrey M; Ritch, Robert
2010-06-01
To evaluate the within-session and inter-session repeatability of a new, short-duration transient visual evoked potential (SD-tVEP) device on normal individuals, we tested 30 normal subjects (20/20 visual acuity, normal 24-2 SITA Standard VF) with SD-tVEP. Ten of these subjects had their tests repeated within 1-2 months from the initial visit. Synchronized single-channel EEG was recorded using a modified Diopsys Enfant System (Diopsys, Inc., Pine Brook, New Jersey, USA). A checkerboard stimulus was modulated at two reversals per second. Two different contrasts of checkerboard reversal patterns were used: 85% Michelson contrast with a mean luminance of 66.25 cd/m(2) and 10% Michelson contrast with a mean luminance of 112 cd/m(2). Each test lasted 20 s. Both eyes, independently and together, were tested 10 times (5 times at each contrast level). The following information was identified from the filtered N75-P100-N135 complex: N75 amplitude, N75 latency, P100 amplitude, P100 latency, and Delta Amplitude (N75-P100). The median values for each eye's five SD-tVEP parameters were calculated and grouped into two data sets based on contrast level. Mean age was 27.3 +/- 5.2 years. For OD only, the median (95% confidence intervals) of Delta Amplitude (N75-P100) amplitudes at 10% and 85% contrast were 4.6 uV (4.1-5.9) and 7.1 uV (5.15-9.31). The median P100 latencies were 115.2 ms (112.0-117.7) and 104.0 ms (99.9-106.0). There was little within-session variability for any of these parameters. Intraclass correlation coefficients ranged between 0.64 and 0.98, and within subject coefficients of variation were 3-5% (P100 latency) and 15-30% (Delta Amplitude (N75-P100) amplitude). Bland-Altman plots showed good agreement between the first and fifth test sessions (85% contrast Delta Amplitude (N75-P100) delta amplitude, mean difference, 0.48 mV, 95% CI, -0.18-1.12; 85% contrast P100 latency delay, -0.82 ms, 95% CI, -3.12-1.46; 10% contrast Delta Amplitude (N75-P100) amplitude, 0.58 mV, 95% CI, -0.27-1.45; 10% contrast P100 latency delay, -2.05 mV, 95% CI, -5.12-1.01). The inter-eye correlation and agreement were significant for both SD-tVEP amplitude and P100 latency measurements. For the subset of eyes in which the inter-session repeatability was tested, the intraclass correlation coefficients ranged between 0.71 and 0.86 with good agreement shown on Bland-Altman plots. Short-duration transient VEP technology showed good within-session, inter-session repeatability, and good inter-eye correlation and agreement.
NASA Technical Reports Server (NTRS)
Wang, L.; Shin, R. T.; Kong, J. A.; Yueh, S. H.
1993-01-01
This paper investigates the potential application of neural network to inversion of soil moisture using polarimetric remote sensing data. The neural network used for the inversion of soil parameters is multi-layer perceptron trained with the back-propagation algorithm. The training data include the polarimetric backscattering coefficients obtained from theoretical surface scattering models together with an assumed nominal range of soil parameters which are comprised of the soil permittivity and surface roughness parameters. Soil permittivity is calculated from the soil moisture and the assumed soil texture based on an empirical formula at C-, L-, and P-bands. The rough surface parameters for the soil surface, which is described by the Gaussian random process, are the root-mean-square (rms) height and correlation length. For the rough surface scattering, small perturbation method is used for the L-band frequency, and Kirchhoff approximation is used for the C-band frequency to obtain the corresponding backscattering coefficients. During the training, the backscattering coefficients are the inputs to the neural net and the output from the net are compared with the desired soil parameters to adjust the interconnecting weights. The process is repeated for each input-output data entry and then for the entire training data until convergence is reached. After training, the backscattering coefficients are applied to the trained neural net to retrieve the soil parameters which are compared with the desired soil parameters to verify the effectiveness of this technique. Several cases are examined. First, for simplicity, the correlation length and rms height of the soil surface are fixed while soil moisture is varied. Soil moisture obtained using the neural networks with either L-band or C-band backscattering coefficients for the HH and VV polarizations as inputs is in good agreement with the desired soil moisture. The neural net output matches the desired output for the soil moisture range of 16 to 60 percent for the C-band case. The next case investigated is to vary both soil moisture and rms height while keeping the correlation length fixed. For this case, C-band backscattering coefficients are not sufficient for retrieving two parameters because the Kirchhoff approximation gives the same HH and VV backscattering coefficients. Therefore, the backscattering coefficients at two different frequency bands are necessary to find both the soil moisture and rms height. Finally, the neural nets are also applied to simultaneously invert soil moisture, rms height, and correlation length. Overall, the soil moisture retrieved from the neural network agrees very well with the desired soil moisture. This suggests that the neural network shows potential for retrieval of soil parameters from remote sensing data.
The Attenuation of Correlation Coefficients: A Statistical Literacy Issue
ERIC Educational Resources Information Center
Trafimow, David
2016-01-01
Much of the science reported in the media depends on correlation coefficients. But the size of correlation coefficients depends, in part, on the reliability with which the correlated variables are measured. Understanding this is a statistical literacy issue.
López-Lira, Claudia; Alzate-Morales, Jans H; Paulino, Margot; Mella-Raipán, Jaime; Salas, Cristian O; Tapia, Ricardo A; Soto-Delgado, Jorge
2018-01-01
A combination of three-dimensional quantitative structure-activity relationship (3D-QSAR), and molecular modelling methods were used to understand the potent inhibitory NAD(P)H:quinone oxidoreductase 1 (NQO1) activity of a set of 52 heterocyclic quinones. Molecular docking results indicated that some favourable interactions of key amino acid residues at the binding site of NQO1 with these quinones would be responsible for an improvement of the NQO1 activity of these compounds. The main interactions involved are hydrogen bond of the amino group of residue Tyr128, π-stacking interactions with Phe106 and Phe178, and electrostatic interactions with flavin adenine dinucleotide (FADH) cofactor. Three models were prepared by 3D-QSAR analysis. The models derived from Model I and Model III, shown leave-one-out cross-validation correlation coefficients (q 2 LOO ) of .75 and .73 as well as conventional correlation coefficients (R 2 ) of .93 and .95, respectively. In addition, the external predictive abilities of these models were evaluated using a test set, producing the predicted correlation coefficients (r 2 pred ) of .76 and .74, respectively. The good concordance between the docking results and 3D-QSAR contour maps provides helpful information about a rational modification of new molecules based in quinone scaffold, in order to design more potent NQO1 inhibitors, which would exhibit highly potent antitumor activity. © 2017 John Wiley & Sons A/S.
Validity and reliability of head posture measurement using Microsoft Kinect.
Oh, Baek-Lok; Kim, Jongmin; Kim, Jongshin; Hwang, Jeong-Min; Lee, Jehee
2014-11-01
To investigate the validity and reliability of Microsoft Kinect-based head tracker (KHT) for measuring head posture. Considering the cervical range of motion (CROM) as a reference, one-dimensional and three-dimensional (1D and 3D) head postures of 12 normal subjects (28-58 years of age; 6 women and 6 men) were obtained using the KHT. The KHT was validated by Pearson's correlation coefficient and intraclass correlation (ICC) coefficient. Test-retest reliability of the KHT was determined by its 95% limit of agreement (LoA) with the Bland-Altman plot. Face recognition success rate was evaluated for each head posture. Measurements of 1D and 3D head posture performed using the KHT were very close to those of the CROM with correlation coefficients of 0.99 and 0.97 (p<0.05), respectively, as well as with an ICC of >0.99 and 0.98, respectively. The reliability tests of the KHT in terms of 1D and 3D head postures had 95% LoA angles of approximately ±2.5° and ±6.5°, respectively. The KHT showed good agreement with the CROM and relatively favourable test-retest reliability. Considering its high performance, convenience and low cost, KHT could be clinically used as a head posture-measuring system. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Wang, Yuan; Wu, Mingwei; Ai, Chunzhi; Wang, Yonghua
2015-01-01
Presently, 151 widely-diverse pyridinylimidazole-based compounds that show inhibitory activities at the TNF-α release were investigated. By using the distance comparison technique (DISCOtech), comparative molecular field analysis (CoMFA), and comparative molecular similarity index analysis (CoMSIA) methods, the pharmacophore models and the three-dimensional quantitative structure-activity relationships (3D-QSAR) of the compounds were explored. The proposed pharmacophore model, including two hydrophobic sites, two aromatic centers, two H-bond donor atoms, two H-bond acceptor atoms, and two H-bond donor sites characterizes the necessary structural features of TNF-α release inhibitors. Both the resultant CoMFA and CoMSIA models exhibited satisfactory predictability (with Q2 (cross-validated correlation coefficient) = 0.557, R2ncv (non-cross-validated correlation coefficient) = 0.740, R2pre (predicted correlation coefficient) = 0.749 and Q2 = 0.598, R2ncv = 0.767, R2pre = 0.860, respectively). Good consistency was observed between the 3D-QSAR models and the pharmacophore model that the hydrophobic interaction and hydrogen bonds play crucial roles in the mechanism of actions. The corresponding contour maps generated by these models provide more diverse information about the key intermolecular interactions of inhibitors with the surrounding environment. All these models have extended the understanding of imidazole-based compounds in the structure-activity relationship, and are useful for rational design and screening of novel 2-thioimidazole-based TNF-α release inhibitors. PMID:26307982
Eustachian Tube Mucosal Inflammation Scale Validation Based on Digital Video Images.
Kivekäs, Ilkka; Pöyhönen, Leena; Aarnisalo, Antti; Rautiainen, Markus; Poe, Dennis
2015-12-01
The most common cause for Eustachian tube dilatory dysfunction is mucosal inflammation. The aim of this study was to validate a scale for Eustachian tube mucosal inflammation, based on digital video clips obtained during diagnostic rigid endoscopy. A previously described four-step scale for grading the degree of inflammation of the mucosa of the Eustachian tube lumen was used for this validation study. A tutorial for use of the scale, including static images and 10 second video clips, was presented to 26 clinicians with various levels of experience. Each clinician then reviewed 35 short digital video samples of Eustachian tubes from patients and rated the degree of inflammation. A subset of the clinicians performed a second rating of the same video clips at a subsequent time. Statistical analysis of the ratings provided inter- and intrarater reliability scores. Twenty-six clinicians with various levels of experience rated a total of 35 videos. Thirteen clinicians rated the videos twice. The overall correlation coefficient for the rating of inflammation severity was relatively good (0.74, 95% confidence interval, 0.72-0.76). The intralevel correlation coefficient for intrarater reliability was high (0.86). For those who rated videos twice, the intralevel correlation coefficient improved after the first rating (0.73, to 0.76), but improvement was not statistically significant. The inflammation scale used for Eustachian tube mucosal inflammation is reliable and this scale can be used with a high level of consistency by clinicians with various levels of experience.
Wang, Yuan; Wu, Mingwei; Ai, Chunzhi; Wang, Yonghua
2015-08-25
Presently, 151 widely-diverse pyridinylimidazole-based compounds that show inhibitory activities at the TNF-α release were investigated. By using the distance comparison technique (DISCOtech), comparative molecular field analysis (CoMFA), and comparative molecular similarity index analysis (CoMSIA) methods, the pharmacophore models and the three-dimensional quantitative structure-activity relationships (3D-QSAR) of the compounds were explored. The proposed pharmacophore model, including two hydrophobic sites, two aromatic centers, two H-bond donor atoms, two H-bond acceptor atoms, and two H-bond donor sites characterizes the necessary structural features of TNF-α release inhibitors. Both the resultant CoMFA and CoMSIA models exhibited satisfactory predictability (with Q(2) (cross-validated correlation coefficient) = 0.557, R(2)ncv (non-cross-validated correlation coefficient) = 0.740, R(2)pre (predicted correlation coefficient) = 0.749 and Q(2) = 0.598, R(2)ncv = 0.767, R(2)pre = 0.860, respectively). Good consistency was observed between the 3D-QSAR models and the pharmacophore model that the hydrophobic interaction and hydrogen bonds play crucial roles in the mechanism of actions. The corresponding contour maps generated by these models provide more diverse information about the key intermolecular interactions of inhibitors with the surrounding environment. All these models have extended the understanding of imidazole-based compounds in the structure-activity relationship, and are useful for rational design and screening of novel 2-thioimidazole-based TNF-α release inhibitors.
Sun, Yangbo; Chen, Long; Huang, Bisheng; Chen, Keli
2017-07-01
As a mineral, the traditional Chinese medicine calamine has a similar shape to many other minerals. Investigations of commercially available calamine samples have shown that there are many fake and inferior calamine goods sold on the market. The conventional identification method for calamine is complicated, therefore as a result of the large scale of calamine samples, a rapid identification method is needed. To establish a qualitative model using near-infrared (NIR) spectroscopy for rapid identification of various calamine samples, large quantities of calamine samples including crude products, counterfeits and processed products were collected and correctly identified using the physicochemical and powder X-ray diffraction method. The NIR spectroscopy method was used to analyze these samples by combining the multi-reference correlation coefficient (MRCC) method and the error back propagation artificial neural network algorithm (BP-ANN), so as to realize the qualitative identification of calamine samples. The accuracy rate of the model based on NIR and MRCC methods was 85%; in addition, the model, which took comprehensive multiple factors into consideration, can be used to identify crude calamine products, its counterfeits and processed products. Furthermore, by in-putting the correlation coefficients of multiple references as the spectral feature data of samples into BP-ANN, a BP-ANN model of qualitative identification was established, of which the accuracy rate was increased to 95%. The MRCC method can be used as a NIR-based method in the process of BP-ANN modeling.
Validation of an adapted arabic version of fibromyalgia syndrome impact questionnaire.
El-Naby, Mai Abd; Hefny, Mohamed Ahmed; Fahim, Ayman Ekram; Awadalla, Magdy Ahmed
2013-10-01
Fibromyalgia (FM) is the most common chronic pain syndrome encountered in medical practice, affecting females more than males, and the estimated prevalence of FM in Egypt is 1.3 %. The aim was to translate and adapt the Fibromyalgia Impact Questionnaire (FIQ) into Arabic and assess reliability and validity. The Arabic version of Fibromyalgia Impact Questionnaire (FIQ-A) was adapted following the forward/backward translation approach. Fifty-one female patients with FM were studied to assess psychometric properties of the FIQ-A. Reliability was analyzed by the correlation coefficient between test and retest. Internal consistency was checked by the Cronbach's alpha coefficient. Construct validity was assessed comparing FIQ-A with Health Assessment Questionnaire (HAQ), Health Assessment Questionnaire of Fibromyalgia (FHAQ), The Medical Outcome Survey Short-Form-36 (SF-36), and the Total Visual Analog Scale (TVAS) for FM symptom, and feasibility was assessed by the time taken in completing the FIQ-A and the proportion of patients completed the questionnaire. Patients studied were 33.2 ± 9.8 years old. Translation was concordant. Adaptation affected 4 sub-items of physical function. Test-retest correlation coefficient was 0.89 for total FIQ-A and Cronbach's alpha was 0.76. Excellent to good statistically significant correlations (p < 0.05) were found between the FIQ-A items and HAQ, FHAQ, and SF-36. The FIQ-A is a reliable, valid for measuring health status and physical function in Arabic-speaking FM patients.
Development and Preliminary Validation of the Coma Arousal Communication Scale.
Garin, Julie; Reina, Margot; DeiCas, Paula; Rousseaux, Marc
To develop a Coma Arousal Communication Scale and perform preliminary validation. A group of experts developed a questionnaire to assess communication between patients emerging from coma and caregiver (participation, communication modes, and themes) and the strategies used to facilitate communication. To assess the scale's psychometric characteristics, it was presented to the caregivers of 40 inpatients admitted to 5 coma units and (to obtain reference data) to 29 control participants. The Coma Arousal Communication Scale displayed good intra- and interrater reliability as judged by intraclass correlation coefficients (between 0.76 and 0.98) and Bland and Altman plots. Cohen κ coefficient revealed moderate to almost perfect levels of agreement for most individual items and slight levels for a few items dealing with compensatory strategies. We observed good internal consistency, relations with the Wessex Head Injury Matrix, and sensitivity to change for patients who had sustained brain injury in the previous 6 months. The Coma Arousal Communication Scale provides accurate information about communication skills of individuals emerging from coma. However, some compensatory strategies adopted by caregivers are difficult to characterize.
Sharma, Ph Baleshwor; Handique, Pratap Jyoti; Devi, Huidrom Sunitibala
2015-02-01
Antioxidant properties, physico-chemical characteristics and proximate composition of five wild fruits viz., Garcinia pedunculata, Garcinia xanthochymus, Docynia indica, Rhus semialata and Averrhoa carambola grown in Manipur, India were presented in the current study. The order of the antioxidant activity and reducing power of the fruit samples was found as R. semialata > D. indica > G. xanthochymus > A. carambola > G. pedunculata. Good correlation coefficient (R(2) > 0.99) was found among the three methods applied to determine antioxidant activity. Total phenolic content was positively correlated (R(2) = 0.960) with the antioxidant activity however, total flavonoid content was not positively correlated with the antioxidant activity. Physico-chemical and proximate composition of these fruits is documented for the first time.
NASA Astrophysics Data System (ADS)
Wang, Weizhou; Zhang, Yu; Ji, Baoming; Tian, Anmin
2011-06-01
The C-Hal (Hal = Cl, Br, or I) bond-length change and the corresponding vibrational frequency shift of the C-Hal stretch upon the C-Hal ⋯Y (Y is the electron donor) halogen bond formation have been determined by using density functional theory computations. Plots of the C-Hal bond-length change versus the corresponding vibrational frequency shift of the C-Hal stretch all give straight lines. The coefficients of determination range from 0.94366 to 0.99219, showing that the correlation between the C-Hal bond-length change and the corresponding frequency shift is very good in the halogen-bonded complexes. The possible effects of vibrational coupling, computational method, and anharmonicity on the bond-length change-frequency shift correlation are discussed in detail.
The psychometric properties of exercise benefits/barriers scale among women
Farahani, Leila Amiri; Parvizy, Soroor; Mohammadi, Eesa; Asadi-Lari, Mohsen; Kazemnejad, Anoshiravan; Hasanpoor-Azgahdy, Seyede Batool; Taghizadeh, Ziba
2017-01-01
Background and objective Despite the numerous health benefits of regular physical activity (PA), physical inactivity is a major health issue among women. The goal of the current study was to measure the validity and reliability assessment of the exercise benefits/barriers scale among women between the ages of 18 and 65 years. This study was carried out among women residing in Khoramroudi neighborhood in Tehran between December 2013 and February 2014. Methods In this descriptive, methodological study, 278 women residing in Khoramroudi neighborhood in Tehran between December 2013 and February 2014 completed three questionnaires: the demographic data form, the Exercise Benefits/Barriers Scale. The construct validity, internal consistency, and stability of the study were measured by confirmatory factor analyses, Cronbach’s alpha, and Spearman Brown correlation coefficient by using SPSS 21 and LISREL 8.80, respectively. Results The confirmatory factor analysis showed the Persian version of EBBS was structured well. The Cronbach’s alpha coefficients for the total scale and its subscales were 0.927, 0.94 and 0.82, respectively. Spearman Brown correlation coefficient also showed good test-retest reliability. Conclusion The results of this study verified the reliability and validity of the applied instrument and introduced it as a tool to measure the benefits and barriers of physical activity among Iranian women. PMID:28894535
The psychometric properties of exercise benefits/barriers scale among women.
Farahani, Leila Amiri; Parvizy, Soroor; Mohammadi, Eesa; Asadi-Lari, Mohsen; Kazemnejad, Anoshiravan; Hasanpoor-Azgahdy, Seyede Batool; Taghizadeh, Ziba
2017-07-01
Despite the numerous health benefits of regular physical activity (PA), physical inactivity is a major health issue among women. The goal of the current study was to measure the validity and reliability assessment of the exercise benefits/barriers scale among women between the ages of 18 and 65 years. This study was carried out among women residing in Khoramroudi neighborhood in Tehran between December 2013 and February 2014. In this descriptive, methodological study, 278 women residing in Khoramroudi neighborhood in Tehran between December 2013 and February 2014 completed three questionnaires: the demographic data form, the Exercise Benefits/Barriers Scale. The construct validity, internal consistency, and stability of the study were measured by confirmatory factor analyses, Cronbach's alpha, and Spearman Brown correlation coefficient by using SPSS 21 and LISREL 8.80, respectively. The confirmatory factor analysis showed the Persian version of EBBS was structured well. The Cronbach's alpha coefficients for the total scale and its subscales were 0.927, 0.94 and 0.82, respectively. Spearman Brown correlation coefficient also showed good test-retest reliability. The results of this study verified the reliability and validity of the applied instrument and introduced it as a tool to measure the benefits and barriers of physical activity among Iranian women.
Liu, Song; Zhang, Yujuan; Xia, Jie; Chen, Ling; Guan, Wenxian; Guan, Yue; Ge, Yun; He, Jian; Zhou, Zhengyang
2017-10-01
To explore the application of histogram analysis in preoperative T and N staging of gastric cancers, with a focus on characteristic parameters of apparent diffusion coefficient (ADC) maps. Eighty-seven patients with gastric cancers underwent diffusion weighted magnetic resonance imaging (b=0, 1000s/mm 2 ), which generated ADC maps. Whole-volume histogram analysis was performed on ADC maps and 7 characteristic parameters were obtained. All those patients underwent surgery and postoperative pathologic T and N stages were determined. Four parameters, including skew, kurtosis, s-sD av and sample number, showed significant differences among gastric cancers at different T and N stages. Most parameters correlated with T and N stages significantly and worked in differentiating gastric cancers at different T or N stages. Especially skew yielded a sensitivity of 0.758, a specificity of 0.810, and an area under the curve (AUC) of 0.802 for differentiating gastric cancers with and without lymph node metastasis (P<0.001). All the parameters, except AUC low , showed good or excellent inter-observer agreement with intra-class correlation coefficients ranging from 0.710 to 0.991. Characteristic parameters derived from whole-volume ADC histogram analysis could help assessing preoperative T and N stages of gastric cancers. Copyright © 2017. Published by Elsevier Inc.
[Analysis of reliability and validity of the Chinese Version of Dizziness Handicap Inventory (DHI)].
Zhang, Yi; Liu, Bo; Wang, Yongjun; Zhou, Yun; Wang, Rui; Gong, Jing; Peng, Xiaoxia
2015-09-01
To investigate the reliability and validity of the Chinese Version of Dizziness Handicap Inventory (DHI). Cross-cultural adaptation of health-related quality of life measures was used for translating the DHI to Chinese version. The DHI contains 7 physical, 9 emotional, and 9 functional questions.The patients scored the DHI straightforward. Then the scores of the total scale and each subscales were calculated and evaluated.Three hundred and sixty-six dizzy patients,116 males and 250 females, aged from 14 to 79 years, were included in the research and finished the questionnaire of the evaluation.SPSS 13.0 was used for statistical analysis. Reliability: Cronbach α values for the total and subscale of DHI were 0.751-0.912. The reliability coefficients were 0.877-0.921 (P < 0.001). the correlation coefficients between the total scale and three subscale were 0.815-0.934 (P < 0.001). The correlation coefficients of the scores internal the subscale were higher than between the other subscale (r = 0.446-0.781). Common factor analysis provides 5 factors. The cumulative variance ratio was 54.5%. The component of each item was over 0.4. Chinese version of DHI has good reliability and validity, which can be used to evaluate the dizzy patients.
Jensen, K K; Kjaer, M; Jorgensen, L N
2016-12-01
To determine the reliability of measurements obtained by the Good Strength dynamometer, determining isometric abdominal wall and back muscle strength in patients with ventral incisional hernia (VIH) and healthy volunteers with an intact abdominal wall. Ten patients with VIH and ten healthy volunteers with an intact abdominal wall were each examined twice with a 1 week interval. Examination included the assessment of truncal flexion and extension as measured with the Good Strength dynamometer, the completion of the International Physical Activity Questionnaire (IPAQ) and the self-assessment of truncal strength on a visual analogue scale (SATS). The test-retest reliability of truncal flexion and extension was assessed by interclass correlation coefficient (ICC), and Bland and Altman graphs. Finally, correlations between truncal strength, and IPAQ and SATS were examined. Truncal flexion and extension showed excellent test-retest reliability for both patients with VIH (ICC 0.91 and 0.99) and healthy controls (ICC 0.97 and 0.96). Bland and Altman plots showed that no systematic bias was present for neither truncal flexion nor extension when assessing reliability. For patients with VIH, no significant correlations between objective measures of truncal strength and IPAQ or SATS were found. For healthy controls, both truncal flexion (τ 0.58, p = 0.025) and extension (τ 0.58, p = 0.025) correlated significantly with SATS, while no other significant correlation between truncal strength measures and IPAQ was found. The Good Strength dynamometer provided a reliable, low-cost measure of truncal flexion and extension in patients with VIH.
Diffusion coefficients of nitric oxide in water: A molecular dynamics study
NASA Astrophysics Data System (ADS)
Pokharel, Sunil; Pantha, Nurapati; Adhikari, N. P.
2016-09-01
Self-diffusion coefficients along with the mutual diffusion coefficients of nitric oxide (NO) and SPC/E water (H2O) as solute and solvent of the mixture, have been studied within the framework of classical molecular dynamics level of calculations using GROMACS package. The radial distribution function (RDF) of the constituent compounds are calculated to study solute-solute, solute-solvent and solvent-solvent molecular interactions as a function of temperature. A dilute solution of five NO molecules (mole fraction 0.018) and 280 H2O molecules (mole fraction 0.982) has been taken as the sample. The self-diffusion coefficient of the solvent is calculated by using mean square displacement (MSD) where as that for solute (NO) is calculated by using MSD and velocity auto-correlation function (VACF). The results are then compared with the available experimental values. The results from the present work for water come in good agreement, very precise at low temperatures, with the experimental values. The diffusion coefficients of NO, on the other hands, agree well with the available theoretical studies, and also with experiment at low temperatures (up to 310 K). The results at the higher temperatures (up to 333 K), however, deviate significantly with the experimental observations. Also, the mutual diffusion coefficients of NO in water have been calculated by using Darken’s relation. The temperature dependence of the calculated diffusion coefficients follow the Arrhenius behavior.
A Comprehensive Set of Impact Data for Common Aerospace Metals
Brake, Matthew; Reu, Phil L.; Aragon, Dannelle S.
2017-05-16
Our results for the two sets of impact experiments are reported here. In order to assist with model development using the impact data reported, the materials are mechanically characterized using a series of standard experiments. The first set of impact data comes from a series of coefficient of restitution experiments, in which a 2 meter long pendulum is used to study "in context" measurements of the coefficient of restitution for eight different materials (6061-T6 Aluminum, Phosphor Bronze alloy 510, Hiperco, Nitronic 60A, Stainless Steel 304, Titanium, Copper, and Annealed Copper). The coefficient of restitution is measured via two different techniques:more » digital image correlation and laser Doppler vibrometry. Due to the strong agreement of the two different methods, only results from the digital image correlation are reported. The coefficient of restitution experiments are "in context" as the scales of the geometry and impact velocities are representative of common features in the motivating application for this research. Finally, a series of compliance measurements are detailed for the same set of materials. Furthermore, the compliance measurements are conducted using both nano-indentation and micro-indentation machines, providing sub-nm displacement resolution and uN force resolution. Good agreement is seen for load levels spanned by both machines. As the transition from elastic to plastic behavior occurs at contact displacements on the order of 30 nm, this data set provides a unique insight into the transitionary region.« less
A Comprehensive Set of Impact Data for Common Aerospace Metals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brake, Matthew; Reu, Phil L.; Aragon, Dannelle S.
Our results for the two sets of impact experiments are reported here. In order to assist with model development using the impact data reported, the materials are mechanically characterized using a series of standard experiments. The first set of impact data comes from a series of coefficient of restitution experiments, in which a 2 meter long pendulum is used to study "in context" measurements of the coefficient of restitution for eight different materials (6061-T6 Aluminum, Phosphor Bronze alloy 510, Hiperco, Nitronic 60A, Stainless Steel 304, Titanium, Copper, and Annealed Copper). The coefficient of restitution is measured via two different techniques:more » digital image correlation and laser Doppler vibrometry. Due to the strong agreement of the two different methods, only results from the digital image correlation are reported. The coefficient of restitution experiments are "in context" as the scales of the geometry and impact velocities are representative of common features in the motivating application for this research. Finally, a series of compliance measurements are detailed for the same set of materials. Furthermore, the compliance measurements are conducted using both nano-indentation and micro-indentation machines, providing sub-nm displacement resolution and uN force resolution. Good agreement is seen for load levels spanned by both machines. As the transition from elastic to plastic behavior occurs at contact displacements on the order of 30 nm, this data set provides a unique insight into the transitionary region.« less
Reliability and validity of a Chinese version of the Diagnostic Interview for Borderlines-Revised.
Wang, Lanlan; Yuan, Chenmei; Qiu, Jianying; Gunderson, John; Zhang, Min; Jiang, Kaida; Leung, Freedom; Zhong, Jie; Xiao, Zeping
2014-09-01
Borderline personality disorder (BPD) is the most studied of the axis II disorders. One of the most widely used diagnostic instruments is the Diagnostic Interview for Borderline Patients-Revised (DIB-R). The aim of this study was to test the reliability and validity of DIB-R for use in the Chinese culture. The reliability and validity of the DIB-R Chinese version were assessed in a sample of 236 outpatients with a probable BPD diagnosis. The Structured Clinical Interview for DSM-IV Personality Disorders (SCID-II) was used as a standard. Test-retest reliability was tested six months later with 20 patients, and inter-rater reliability was tested on 32 patients. The Chinese version of the DIB-R showed good internal global consistency (Cronbach's α of 0.916), good test-retest reliability (Pearson correlation of 0.704), good inter-rater reliability (intra-class correlation coefficient of 0.892 and kappa of 0.861). When compared with the DSM-IV diagnosis as measured by the SCID-II, the DIB-R showed relatively good sensitivity (0.768) and specificity (0.891) at the cutoff of 7, moderate diagnostic convergence (kappa of 0.631), as well as good discriminating validity. The Chinese version of the DIB-R has good psychometric properties, which renders it a valuable method for examining the presence, the severity, and component phenotypes of BPD in Chinese samples. © 2013 Wiley Publishing Asia Pty Ltd.
De Groef, An; Van Kampen, Marijke; Moortgat, Peter; Anthonissen, Mieke; Van den Kerckhove, Eric; Christiaens, Marie-Rose; Neven, Patrick; Geraerts, Inge; Devoogdt, Nele
2018-01-01
To investigate the concurrent, face and content validity of an evaluation tool for Myofascial Adhesions in Patients after Breast Cancer (MAP-BC evaluation tool). 1) Concurrent validity of the MAP-BC evaluation tool was investigated by exploring correlations (Spearman's rank Correlation Coefficient) between the subjective scores (0 -no adhesions to 3 -very strong adhesions) of the skin level using the MAP-BC evaluation tool and objective elasticity parameters (maximal skin extension and gross elasticity) generated by the Cutometer Dual MPA 580. Nine different examination points on and around the mastectomy scar were evaluated. 2) Face and content validity were explored by questioning therapists experienced with myofascial therapy in breast cancer patients about the comprehensibility and comprehensiveness of the MAP-BC evaluation tool. 1) Only three meaningful correlations were found on the mastectomy scar. For the most lateral examination point on the mastectomy scar a moderate negative correlation (-0.44, p = 0.01) with the maximal skin extension and a moderate positive correlation with the resistance versus ability of returning or 'gross elasticity' (0.42, p = 0.02) were found. For the middle point on the mastectomy scar an almost moderate positive correlation with gross elasticity was found as well (0.38, p = 0.04) 2) Content and face validity have been found to be good. Eighty-nine percent of the respondent found the instructions understandable and 98% found the scoring system obvious. Thirty-seven percent of the therapists suggested to add the possibility to evaluate additional anatomical locations in case of reconstructive and/or bilateral surgery. The MAP-BC evaluation tool for myofascial adhesions in breast cancer patients has good face and content validity. Evidence for good concurrent validity of the skin level was found only on the mastectomy scar itself.
Correlated Debye model for atomic motions in metal nanocrystals
NASA Astrophysics Data System (ADS)
Scardi, P.; Flor, A.
2018-05-01
The Correlated Debye model for the mean square relative displacement of atoms in near-neighbour coordination shells has been extended to include the effect of finite crystal size. This correctly explains the increase in Debye-Waller coefficient observed for metal nanocrystals. A good match with Molecular Dynamics simulations of Pd nanocrystals is obtained if, in addition to the phonon confinement effect of the finite domain size, proper consideration is also given to the static disorder component caused by the undercoordination of surface atoms. The new model, which addresses the analysis of the Pair Distribution Function and powder diffraction data collected at different temperatures, was preliminarily tested on recently published experimental data on nanocrystalline Pt powders.
Thin-film amperometric multibiosensor for simultaneous determination of lactate and glucose in wine.
Shkotova, Lyudmyla V; Piechniakova, Nataliia Y; Kukla, Oleksandr L; Dzyadevych, Sergei V
2016-04-15
An amperometric multi-biosensor based on lactate and glucose oxidases has been developed for determination of lactate and glucose in wine. Gold thin-film amperometric electrodes were used as multi-transducers. Analytical characteristics of the multi-biosensor developed were studied. The minimum detectable concentration was 5×10(-6) mol/l for both glucose and lactate. High reproducibility and storage stability of the multi-biosensor are demonstrated in this paper. Lactate and glucose were determined in wine, and a good correlation was obtained with concentrations determined using high-performance liquid chromatography (correlation coefficient for glucose R(2)=0.998, for lactate R(2)=0.718). Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Marubashi, K.
1995-01-01
Correlations between interplanetary magnetic fields (IMFs) at 0.72 AU and 1.0 AU have been examined using data sets obtained from the Pioneer Venus orbiter and Earth-orbiting spacecraft. While the two-sector structures are evident in long-term variations at these two heliocentric distances, the corresponding auto-correlation coefficients are consistently smaller at 1.0 AU than at 0.72 AU. This suggests that the IMF structures become less persistent at 1.0 AU due to the effects of changing solar wind dynamics between the Venus and Earth orbits. Short-term variations exhibit generally poor correlations between IMFs near Venus and those near Earth, though good correlations are sometimes obtained for well-defined structures when the Sun, Venus, and Earth are closely aligned. The rather poor correlations in the background streams indicate that the IMFs are still changing between the Venus and Earth orbits under the strong influence of solar wind dynamics.
Preliminary Survey on TRY Forest Traits and Growth Index Relations - New Challenges
NASA Astrophysics Data System (ADS)
Lyubenova, Mariyana; Kattge, Jens; van Bodegom, Peter; Chikalanov, Alexandre; Popova, Silvia; Zlateva, Plamena; Peteva, Simona
2016-04-01
Forest ecosystems provide critical ecosystem goods and services, including food, fodder, water, shelter, nutrient cycling, and cultural and recreational value. Forests also store carbon, provide habitat for a wide range of species and help alleviate land degradation and desertification. Thus they have a potentially significant role to play in climate change adaptation planning through maintaining ecosystem services and providing livelihood options. Therefore the study of forest traits is such an important issue not just for individual countries but for the planet as a whole. We need to know what functional relations between forest traits exactly can express TRY data base and haw it will be significant for the global modeling and IPBES. The study of the biodiversity characteristics at all levels and functional links between them is extremely important for the selection of key indicators for assessing biodiversity and ecosystem services for sustainable natural capital control. By comparing the available information in tree data bases: TRY, ITR (International Tree Ring) and SP-PAM the 42 tree species are selected for the traits analyses. The dependence between location characteristics (latitude, longitude, altitude, annual precipitation, annual temperature and soil type) and forest traits (specific leaf area, leaf weight ratio, wood density and growth index) is studied by by multiply regression analyses (RDA) using the statistical software package Canoco 4.5. The Pearson correlation coefficient (measure of linear correlation), Kendal rank correlation coefficient (non parametric measure of statistical dependence) and Spearman correlation coefficient (monotonic function relationship between two variables) are calculated for each pair of variables (indexes) and species. After analysis of above mentioned correlation coefficients the dimensional linear regression models, multidimensional linear and nonlinear regression models and multidimensional neural networks models are built. The strongest dependence between It and WD was obtained. The research will support the work on: Strategic Plan for Biodiversity 2011-2020, modelling and implementation of ecosystem-based approaches to climate change adaptation and disaster risk reduction. Key words: Specific leaf area (SLA), Leaf weight ratio (LWR), Wood density (WD), Growth index (It)
Kurre, Annette; van Gool, Christel J A W; Bastiaenen, Caroline H G; Gloor-Juzi, Thomas; Straumann, Dominik; de Bruin, Eling D
2009-04-01
To translate the Dizziness Handicap Inventory into German (DHI-G) and investigate reliability, assess the association between selected items of the University of California Los Angeles Dizziness Questionnaire and the DHI-G, and compare the scores of patients and healthy participants. Cross-sectional design. Tertiary center for vertigo, dizziness, or balance disorders. One hundred forty-one patients with vertigo, dizziness, and unsteadiness associated with a vestibular disorder, with a mean age (standard deviation) of 51.5 (13.2) years, and 52 healthy individuals participated. Fourteen patients participated in the cognitive debriefing; 127 patients completed the questionnaires once or twice within 1 week. The DHI-G assesses disability caused by dizziness and unsteadiness; the items of the University of California Los Angeles Dizziness Questionnaire assess dizziness and impact on everyday activities. Internal consistency was estimated using Cronbach alpha, reproducibility by calculating Bland-Altman limits of agreement and intraclass correlation coefficients. Associations were estimated by Spearman correlation coefficients. Patients filled out the DHI-G without problem and found that their self-perceived disabilities were mostly included. Cronbach alpha values for the DHI-G and the functional, physical, and emotional subscales were 0.90, 0.80, 0.71, and 0.82, respectively. The limits of agreement were +/-12.4 points for the total scale (maximum, 100 points). Intraclass correlation coefficients ranged from 0.90 to 0.95. The DHI-G correlated moderately with the question assessing functional disability (0.56) and fairly with the questions quantifying dizziness (0.43, 0.35). The DHI-G discriminated significantly between healthy participants and patients. The DHI-G demonstrated good reliability and is recommended as a measure of disability in patients with dizziness and unsteadiness.
Sun, Zhi-Jing; Zhu, Lan; Liang, Maolian; Xu, Tao; Lang, Jing-He
2016-08-01
WeChat is a promising tool for capturing electronic data; however, no research has examined its use. This study evaluates the reliability and feasibility of WeChat for administering the Pelvic Floor Impact Questionnaire Short Form 7 questionnaire to women with pelvic floor disorders. Sixty-eight pelvic floor rehabilitation women were recruited between June and December 2015 and crossover randomized to two groups. All participants completed two questionnaire formats. One group completed the paper version followed by the WeChat version; the other group completed the questionnaires in reverse order. Two weeks later, each group completed the two versions in reverse order. The WeChat version's reliability was assessed using intraclass correlation coefficients and test-retest reliability. Forty-two women (61.8%) preferred the WeChat to the paper format, eight (11.8%) preferred the paper format, and 18 (26.5%) had no preference. The younger women preferred WeChat. Completion time was 116.5 (61.3) seconds for the WeChat version and 133.4 (107.0) seconds for the paper version, with no significant difference (P = 0.145). Age and education did not impact completion time (P > 0.05). Consistency between the WeChat and paper versions was excellent. The intraclass correlation coefficients of the Pelvic Floor Impact Questionnaire Short Form 7 and the three subscales ranged from 0.915 to 0.980. The Bland-Altman analysis and linear regression results also showed high consistency. The test-retest study had a Pearson's correlation coefficient of 0.908, demonstrating a strong correlation. WeChat-based questionnaires were well accepted by women with pelvic floor disorders and had good data quality and reliability.
Dehghan, M; Ilow, R; Zatonska, K; Szuba, A; Zhang, X; Mente, A; Regulska-Ilow, B
2012-06-01
A food frequency questionnaire (FFQ) is the most commonly used method in large epidemiological studies. The validation of an FFQ is essential for specific populations because foods are culture-dependent. The present study aimed to develop an FFQ and evaluate its validity and reproducibility in estimating the intake of nutrients in urban and rural areas of Poland. Adult participants (n = 146) in the Polish arm of the ongoing Prospective Urban and Rural Epidemiological (PURE) study completed FFQs on two occasions, as well as four 24-h dietary recalls (DRs) during a 12-month period. Correlation coefficients (r) and de-attenuated correlation coefficients between dietary recalls and both FFQs were calculated for selected macro- and micronutrients. Agreement between the two methods was evaluated by classification into quartiles and the Bland-Altman method. Reproducibility was assessed by the intra-class correlation coefficient (ICC). The final food list contained 134 food items. For urban participants, FFQ2 generally underestimated energy, protein and fat compared to the FFQ1 and mean of DRs. In rural areas, compared to DRs, both FFQs overestimated energy and macronutrients. For both urban and rural settings, de-attenuated correlation exceeded 0.4 for almost all nutrients and the exact agreement in quartile categorisation was >66%. When assessing repeatability, ICC varied from 0.39-0.63 in an urban setting and 0.19-0.45 in a rural setting. This 134-item FFQ has good validity and reproducibility in relation to the reference method and can be used to rank individuals based on their macro- and micronutrient intake. © 2012 The Authors. Journal of Human Nutrition and Dietetics © 2012 The British Dietetic Association Ltd.
Pisconti, Fernando; Mahmoud Smaili Santos, Suhaila; Lopes, Josiane; Rosa Cardoso, Jefferson; Lopes Lavado, Edson
2017-11-29
The Exercise Self-Efficacy scale (ESES) is a reliable measure, in the English language, of exercise self-efficacy in individuals with spinal cord injury. The aim of this study was to culturally adjust and validate the Exercise Self-Efficacy scale in the Portuguese language. The Exercise Self-Efficacy scale was applied to 76 subjects, with three-month intervals (three applications in total). The reliability was appraised using the intra-class correlation coefficient and Bland-Altman methods, and the internal consistency was evaluated using Cronbach´s alpha. The Exercise Self-Efficacy scale was correlated with the domains of the Quality of life Questionnaire SF-36 and Functional Independence Measure and tested using the Spearman rho coefficient. The Exercise Self-Efficacy scale-Brazil presented good internal consistency (alpha 1 = 0.856; alpha 2 = 0.855; alpha 3 = 0.822) and high reliability in the test-retest (intra-class correlation coefficient = 0.97). There was a strong correlation between the Exercise Self-Efficacy scale-Brazil and the SF-36 only in the functional capacity domain (rho = 0.708). There were no changes in Exercise Self-Efficacy scale-Brazil scores between the three applications (p = 0.796). The validation of the Exercise Self-Efficacy scale questionnaire permits the assessor to use it reliably in Portuguese speaking countries, since it is the first instrument measuring self-efficacy specifically during exercises in individuals with spinal cord injury. Furthermore, the questionnaire can be used as an instrument to verify the effectiveness of interventions that use exercise as an outcome. The results of the Brazilian version of the Exercise Self-Efficacy scale support its use as a reliable and valid measurement of exercise self-efficacy for this population.
Psychometric assessment of a scale to measure bonding workplace social capital
Tsutsumi, Akizumi; Inoue, Akiomi; Odagiri, Yuko
2017-01-01
Objectives Workplace social capital (WSC) has attracted increasing attention as an organizational and psychosocial factor related to worker health. This study aimed to assess the psychometric properties of a newly developed WSC scale for use in work environments, where bonding social capital is important. Methods We assessed the psychometric properties of a newly developed 6-item scale to measure bonding WSC using two data sources. Participants were 1,650 randomly selected workers who completed an online survey. Exploratory factor analyses were conducted. We examined the item–item and item–total correlations, internal consistency, and associations between scale scores and a previous 8-item measure of WSC. We evaluated test–retest reliability by repeating the survey with 900 of the respondents 2 weeks later. The overall scale reliability was quantified by an intraclass coefficient and the standard error of measurement. We evaluated convergent validity by examining the association with several relevant workplace psychosocial factors using a dataset from workers employed by an electrical components company (n = 2,975). Results The scale was unidimensional. The item–item and item–total correlations ranged from 0.52 to 0.78 (p < 0.01) and from 0.79 to 0.89 (p < 0.01), respectively. Internal consistency was good (Cronbach’s α coefficient: 0.93). The correlation with the 8-item scale indicated high criterion validity (r = 0.81) and the scale showed high test–retest reliability (r = 0.74, p < 0.01). The intraclass coefficient and standard error of measurement were 0.74 (95% confidence intervals: 0.71–0.77) and 4.04 (95% confidence intervals: 1.86–6.20), respectively. Correlations with relevant workplace psychosocial factors showed convergent validity. Conclusions The results confirmed that the newly developed WSC scale has adequate psychometric properties. PMID:28662058
Validation of a quantitative Eimeria spp. PCR for fresh droppings of broiler chickens.
Peek, H W; Ter Veen, C; Dijkman, R; Landman, W J M
2017-12-01
A quantitative Polymerase Chain Reaction (qPCR) for the seven chicken Eimeria spp. was modified and validated for direct use on fresh droppings. The analytical specificity of the qPCR on droppings was 100%. Its analytical sensitivity (non-sporulated oocysts/g droppings) was 41 for E. acervulina, ≤2900 for E. brunetti, 710 for E. praecox, 1500 for E. necatrix, 190 for E. tenella, 640 for E. maxima, and 1100 for E. mitis. Field validation of the qPCR was done using droppings with non-sporulated oocysts from 19 broiler flocks. To reduce the number of qPCR tests five grams of each pooled sample (consisting of ten fresh droppings) per time point were blended into one mixed sample. Comparison of the oocysts per gram (OPG)-counting method with the qPCR using pooled samples (n = 1180) yielded a Pearson's correlation coefficient of 0.78 (95% CI: 0.76-0.80) and a Pearson's correlation coefficient of 0.76 (95% CI: 0.70-0.81) using mixed samples (n = 236). Comparison of the average of the OPG-counts of the five pooled samples with the mixed sample per time point (n = 236) showed a Pearson's correlation coefficient (R) of 0.94 (95% CI: 0.92-0.95) for the OPG-counting method and 0.87 (95% CI: 0.84-0.90) for the qPCR. This indicates that mixed samples are practically equivalent to the mean of five pooled samples. The good correlation between the OPG-counting method and the qPCR was further confirmed by the visual agreement between the total oocyst/g shedding patterns measured with both techniques in the 19 broiler flocks using the mixed samples.
Zhe Fan; Zhong Wang; Guanglin Li; Ruomei Wang
2016-08-01
Motion classification system based on surface Electromyography (sEMG) pattern recognition has achieved good results in experimental condition. But it is still a challenge for clinical implement and practical application. Many factors contribute to the difficulty of clinical use of the EMG based dexterous control. The most obvious and important is the noise in the EMG signal caused by electrode shift, muscle fatigue, motion artifact, inherent instability of signal and biological signals such as Electrocardiogram. In this paper, a novel method based on Canonical Correlation Analysis (CCA) was developed to eliminate the reduction of classification accuracy caused by electrode shift. The average classification accuracy of our method were above 95% for the healthy subjects. In the process, we validated the influence of electrode shift on motion classification accuracy and discovered the strong correlation with correlation coefficient of >0.9 between shift position data and normal position data.
Diagnosing cysts with correlation coefficient images from 2-dimensional freehand elastography.
Booi, Rebecca C; Carson, Paul L; O'Donnell, Matthew; Richards, Michael S; Rubin, Jonathan M
2007-09-01
We compared the diagnostic potential of using correlation coefficient images versus elastograms from 2-dimensional (2D) freehand elastography to characterize breast cysts. In this preliminary study, which was approved by the Institutional Review Board and compliant with the Health Insurance Portability and Accountability Act, we imaged 4 consecutive human subjects (4 cysts, 1 biopsy-verified benign breast parenchyma) with freehand 2D elastography. Data were processed offline with conventional 2D phase-sensitive speckle-tracking algorithms. The correlation coefficient in the cyst and surrounding tissue was calculated, and appearances of the cysts in the correlation coefficient images and elastograms were compared. The correlation coefficient in the cysts was considerably lower (14%-37%) than in the surrounding tissue because of the lack of sufficient speckle in the cysts, as well as the prominence of random noise, reverberations, and clutter, which decorrelated quickly. Thus, the cysts were visible in all correlation coefficient images. In contrast, the elastograms associated with these cysts each had different elastographic patterns. The solid mass in this study did not have the same high decorrelation rate as the cysts, having a correlation coefficient only 2.1% lower than that of surrounding tissue. Correlation coefficient images may produce a more direct, reliable, and consistent method for characterizing cysts than elastograms.
Prospective comparison of speckle tracking longitudinal bidimensional strain between two vendors.
Castel, Anne-Laure; Szymanski, Catherine; Delelis, François; Levy, Franck; Menet, Aymeric; Mailliet, Amandine; Marotte, Nathalie; Graux, Pierre; Tribouilloy, Christophe; Maréchaux, Sylvestre
2014-02-01
Speckle tracking is a relatively new, largely angle-independent technique used for the evaluation of myocardial longitudinal strain (LS). However, significant differences have been reported between LS values obtained by speckle tracking with the first generation of software products. To compare LS values obtained with the most recently released equipment from two manufacturers. Systematic scanning with head-to-head acquisition with no modification of the patient's position was performed in 64 patients with equipment from two different manufacturers, with subsequent off-line post-processing for speckle tracking LS assessment (Philips QLAB 9.0 and General Electric [GE] EchoPAC BT12). The interobserver variability of each software product was tested on a randomly selected set of 20 echocardiograms from the study population. GE and Philips interobserver coefficients of variation (CVs) for global LS (GLS) were 6.63% and 5.87%, respectively, indicating good reproducibility. Reproducibility was very variable for regional and segmental LS values, with CVs ranging from 7.58% to 49.21% with both software products. The concordance correlation coefficient (CCC) between GLS values was high at 0.95, indicating substantial agreement between the two methods. While good agreement was observed between midwall and apical regional strains with the two software products, basal regional strains were poorly correlated. The agreement between the two software products at a segmental level was very variable; the highest correlation was obtained for the apical cap (CCC 0.90) and the poorest for basal segments (CCC range 0.31-0.56). A high level of agreement and reproducibility for global but not for basal regional or segmental LS was found with two vendor-dependent software products. This finding may help to reinforce clinical acceptance of GLS in everyday clinical practice. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Armstrong, Anderson C; Gjesdal, Ola; Almeida, André; Nacif, Marcelo; Wu, Colin; Bluemke, David A; Brumback, Lyndia; Lima, João A C
2014-01-01
Left ventricular mass (LVM) and hypertrophy (LVH) are important parameters, but their use is surrounded by controversies. We compare LVM by echocardiography and cardiac magnetic resonance (CMR), investigating reproducibility aspects and the effect of echocardiography image quality. We also compare indexing methods within and between imaging modalities for classification of LVH and cardiovascular risk. Multi-Ethnic Study of Atherosclerosis enrolled 880 participants in Baltimore city, 146 had echocardiograms and CMR on the same day. LVM was then assessed using standard techniques. Echocardiography image quality was rated (good/limited) according to the parasternal view. LVH was defined after indexing LVM to body surface area, height(1.7) , height(2.7) , or by the predicted LVM from a reference group. Participants were classified for cardiovascular risk according to Framingham score. Pearson's correlation, Bland-Altman plots, percent agreement, and kappa coefficient assessed agreement within and between modalities. Left ventricular mass by echocardiography (140 ± 40 g) and by CMR were correlated (r = 0.8, P < 0.001) regardless of the echocardiography image quality. The reproducibility profile had strong correlations and agreement for both modalities. Image quality groups had similar characteristics; those with good images compared to CMR slightly superiorly. The prevalence of LVH tended to be higher with higher cardiovascular risk. The agreement for LVH between imaging modalities ranged from 77% to 98% and the kappa coefficient from 0.10 to 0.76. Echocardiography has a reliable performance for LVM assessment and classification of LVH, with limited influence of image quality. Echocardiography and CMR differ in the assessment of LVH, and additional differences rise from the indexing methods. © 2013. This article is a U.S. Government work and is in the public domain in the USA.
Armstrong, Anderson C.; Gjesdal, Ola; Almeida, André; Nacif, Marcelo; Wu, Colin; Bluemke, David A.; Brumback, Lyndia; Lima, João A. C.
2013-01-01
BACKGROUND Left ventricular mass (LVM) and hypertrophy (LVH) are important parameters, but their use is surrounded by controversies. We compare LVM by echocardiography and cardiac magnetic resonance (CMR), investigating reproducibility aspects and the effect of echocardiography image quality. We also compare indexing methods within and between imaging modalities for classification of LVH and cardiovascular risk. METHODS MESA enrolled 880 participants in Baltimore City; 146 had echocardiograms and CMR on the same day. LVM was then assessed using standard techniques. Echocardiography image quality was rated (good/limited) according to the parasternal view. LVH was defined after indexing LVM to body surface area, height1.7, height2.7, or by the predicted LVM from a reference group. Participants were classified for cardiovascular risk according to Framingham score. Pearson’s correlation, Bland-Altman plots, percent agreement, and kappa coefficient assessed agreement within and between modalities. RESULTS LVM by echocardiography (140 ± 40 g) and by CMR were correlated (r = 0.8, p < 0.001) regardless of the echocardiography image quality. The reproducibility profile had strong correlations and agreement for both modalities. Image quality groups had similar characteristics; those with good images compared to CMR slightly superiorly. The prevalence of LVH tended to be higher with higher cardiovascular risk. The agreement for LVH between imaging modalities ranged from 77% to 98% and the kappa coefficient from 0.10 to 0.76. CONCLUSIONS Echocardiography has a reliable performance for LVM assessment and classification of LVH, with limited influence of image quality. Echocardiography and CMR differ in the assessment of LVH, and additional differences rise from the indexing methods. PMID:23930739
Estimating Premorbid Cognitive Abilities in Low-Educated Populations
Apolinario, Daniel; Brucki, Sonia Maria Dozzi; Ferretti, Renata Eloah de Lucena; Farfel, José Marcelo; Magaldi, Regina Miksian; Busse, Alexandre Leopold; Jacob-Filho, Wilson
2013-01-01
Objective To develop an informant-based instrument that would provide a valid estimate of premorbid cognitive abilities in low-educated populations. Methods A questionnaire was drafted by focusing on the premorbid period with a 10-year time frame. The initial pool of items was submitted to classical test theory and a factorial analysis. The resulting instrument, named the Premorbid Cognitive Abilities Scale (PCAS), is composed of questions addressing educational attainment, major lifetime occupation, reading abilities, reading habits, writing abilities, calculation abilities, use of widely available technology, and the ability to search for specific information. The validation sample was composed of 132 older Brazilian adults from the following three demographically matched groups: normal cognitive aging (n = 72), mild cognitive impairment (n = 33), and mild dementia (n = 27). The scores of a reading test and a neuropsychological battery were adopted as construct criteria. Post-mortem inter-informant reliability was tested in a sub-study with two relatives from each deceased individual. Results All items presented good discriminative power, with corrected item-total correlation varying from 0.35 to 0.74. The summed score of the instrument presented high correlation coefficients with global cognitive function (r = 0.73) and reading skills (r = 0.82). Cronbach's alpha was 0.90, showing optimal internal consistency without redundancy. The scores did not decrease across the progressive levels of cognitive impairment, suggesting that the goal of evaluating the premorbid state was achieved. The intraclass correlation coefficient was 0.96, indicating excellent inter-informant reliability. Conclusion The instrument developed in this study has shown good properties and can be used as a valid estimate of premorbid cognitive abilities in low-educated populations. The applicability of the PCAS, both as an estimate of premorbid intelligence and cognitive reserve, is discussed. PMID:23555894
Ozturk, Erhan Arif; Kocer, Bilge Gonenli; Umay, Ebru; Cakci, Aytul
2018-06-07
The objectives of the present study were to translate and cross-culturally adapt the English version of the Parkinson Fatigue Scale into Turkish, to evaluate its psychometric properties, and to compare them with that of other language versions. A total of 144 patients with idiopathic Parkinson disease were included in the study. The Turkish version of Parkinson Fatigue Scale was evaluated for data quality, scaling assumptions, acceptability, reliability, and validity. The questionnaire response rate was 100% for both test and retest. The percentage of missing data was zero for items, and the percentage of computable scores was full. Floor and ceiling effects were absent. The Parkinson Fatigue Scale provides an acceptable internal consistency (Cronbach's alpha was 0.974 for 1st test and 0.964 for a retest, and corrected item-to-total correlations were ranged from 0.715 to 0.906) and test-retest reliability (Cohen's kappa coefficients were ranged from 0.632 to 0.786 for individuals items, and intraclass correlation coefficient was 0.887 for the overall Parkinson Fatigue Scale Score). An exploratory factor analysis of the items revealed a single factor explaining 71.7% of variance. The goodness-of-fit statistics for the one-factorial confirmatory factor analysis were Tucker Lewis index = 0.961, comparative fit index = 0.971 and root mean square error of approximation = 0.077 for a single factor. The average Parkinson Fatigue Scale Score was correlated significantly with sociodemographic data, clinical characteristics and scores of rating scales. The Turkish version of the Parkinson Fatigue Scale seems to be culturally well adapted and have good psychometric properties. The scale can be used in further studies to assess the fatigue in patients with Parkinson's disease.
Huang, Qingmei; Jiang, Ping; Zhang, Zijun; Luo, Jie; Dai, Yun; Zheng, Li; Wang, Wei
2017-12-01
The Memorial Anxiety Scale for Prostate Cancer (MAX-PC) was developed to identify and assess cancer-specific anxiety among men with prostate cancer (PCa); however, there is no Chinese version. The aim of our study was to translate the English version of MAX-PC into Chinese and evaluate the psychometric properties of it. The study cohort comprised 254 participants. Internal consistency including the Cronbach's alpha coefficient and item-total correlations were used to measure the reliability of the scale. Factor structure was analyzed by exploratory factor analysis and concurrent validity by comparing MAX-PC scores with anxiety subscale scores of the Hospital Anxiety and Depression Scale (HADS). Divergent validity was assessed by correlating MAX-PC with HADS depression subscale, while discriminant ability by comparing differences in MAX-PC scores between different patient groups. The Chinese version of MAX-PC demonstrated good reliability; the Cronbach's alpha coefficient for the total and three subscales (prostate cancer anxiety, PSA anxiety, and fear of recurrence) being 0.94, 0.93, 0.82, and 0.85, respectively. Exploratory factor analysis supported the three-factor structure of the scale established in the original version. Despite the somewhat underperformed divergent validity, the scale demonstrated good concurrent validity with a strong correlation with the HADS anxiety subscale (r = 0.71, p < 0.01). Moreover, discriminant ability was demonstrated by ability to differentiate between disease stages. The MAX-PC Chinese version was confirmed to be a valid, reliable instrument and is thus appropriate for identifying and quantifying cancer-specific anxiety in Chinese PCa patients.
Allen, Michael H; Daniel, David G; Revicki, Dennis A; Canuso, Carla M; Turkoz, Ibrahim; Fu, Dong-Jing; Alphs, Larry; Ishak, K Jack; Bartko, John J; Lindenmayer, Jean-Pierre
2012-01-01
The Clinical Global Impression for Schizoaffective Disorder scale is a new rating scale adapted from the Clinical Global Impression scale for use in patients with schizoaffective disorder. The psychometric characteristics of the Clinical Global Impression for Schizoaffective Disorder are described. Content validity was assessed using an investigator questionnaire. Inter-rater reliability was determined with 12 sets of videotaped interviews rated independently by two trained individuals. Test-retest reliability was assessed using 30 randomly selected raters from clinical trials who evaluated the same videos on separate occasions two weeks apart. Convergent and divergent validity and effect size were evaluated by comparing scores between the Clinical Global Impression for Schizoaffective Disorder and the Positive and Negative Syndrome Scale, 21-item Hamilton Rating Scale for Depression, and Young Mania Rating Scale scales using pooled patient data from two clinical trials. Clinical Global Impression for Schizoaffective Disorder scores were then linked to corresponding Positive and Negative Syndrome Scale scores. Content validity was strong. Inter-rater agreement was good to excellent for most scales and subscales (intra-class correlation coefficient ≥ 0.50). Test-retest showed good reproducibility, with intraclass correlation coefficients ranging from 0.444 to 0.898. Spearman correlations between Clinical Global Impression for Schizoaffective Disorder domains and corresponding symptom scales were 0.60 or greater, and effect sizes for Clinical Global Impression for Schizoaffective Disorder overall and domain scores were similar to Positive and Negative Syndrome Scale Young Mania Rating Scale, and 21-item Hamilton Rating Scale for Depression scores. Raters anticipated that the scale might be less effective in distinguishing negative from depressive symptoms, and, in fact, the results here may reflect that clinical reality. Multiple lines of evidence support the reliability and validity of the Clinical Global Impression for Schizoaffective Disorder for studies in schizoaffective disorder.
Ruyssen-Witrand, A; Fernandez-Lopez, C J; Gossec, L; Anract, P; Courpied, J P; Dougados, M
2011-01-01
To evaluate the psychometric properties of the OARSI-OMERACT questionnaires in comparison to the existing validated scales. Consecutive hip or knee osteoarthritis patients consulting in an orthopedic department were enrolled in the study. Data collected were pain using the Intermittent and Constant Osteoarthritis Pain (ICOAP), a Numeric Rating Scale (NRS), the Western Ontario McMaster Universities' Osteoarthritis Index (WOMAC) pain subscale, the Lequesne pain subscale; functional impairment using the Knee disability and Osteoarthritis Outcome Score-Physical Function Shortform (KOOS-PS), the Hip disability and Osteoarthritis Outcome Score-Physical Function Shortform (HOOS-PS), a NRS, the WOMAC function sub-scale, the Lequesne function subscale. Validity was assessed by calculating the Spearman's correlation coefficient between all the scales. Reliability was assessed in out-patients with stable disease comparing the data collected within 2 weeks using the intra-class correlation coefficient (ICC). Responsiveness was assessed on the data from hospitalised patients prior to and 12 weeks after a total joint replacement (TJR) using the standardised response mean. Three hundred patients (mean age=68 years, females=62%, hip OA=57%) were included. There was a moderate to good correlation between ICOAP, KOOS-PS, HOOS-PS and the WOMAC, NRS and Lequesne scales. Reliability of the ICOAP hip OA HOOS-PS and KOOS-PS was good (ICC range 0.80-0.81) whereas it was moderate for knee ICOAP (ICC=0.65). Responsiveness of the ICOAP, KOOS-PS and HOOS-PS 12 weeks after TJR was comparable to responsiveness of other scales (SRM range: 0.54-1.82). The psychometric properties of the ICOAP, KOOS-PS and HOOS-PS were comparable to those of the WOMAC, Lequesne and NRS.
Wei, Xi-Jun; Tong, Kai-Yu; Hu, Xiao-Ling
2011-12-01
Responsiveness of clinical assessments is an important element in the report of clinical effectiveness after rehabilitation. The correlation could reflect the validity of assessments as an indication of clinical performance before and after interventions. This study investigated the correlation and responsiveness of Fugl-Meyer Assessment (FMA), Motor Status Scale (MSS), Action Research Arm Test (ARAT) and the Modified Ashworth Scale (MAS), which are used frequently in effectiveness studies of robotic upper-extremity training in stroke rehabilitation. Twenty-seven chronic stroke patients were recruited for a 20-session upper-extremity rehabilitation robotic training program. This was a rater-blinded randomized controlled trial. All participants were evaluated with FMA, MSS, ARAT, MAS, and Functional Independent Measure before and after robotic training. Spearman's rank correlation coefficient was applied for the analysis of correlation. The standardized response mean (SRM) and Guyatt's responsiveness index (GRI) were used to analyze responsiveness. Spearman's correlation coefficient showed a significantly high correlation (ρ=0.91-0.96) among FMA, MSS, and ARAT and a fair-to-moderate correlation (ρ=0.40-0.62) between MAS and the other assessments. FMA, MSS, and MAS on the wrist showed higher responsiveness (SRM=0.85-0.98, GRI=1.59-3.62), whereas ARAT showed relatively less responsiveness (SRM=0.22, GRI=0.81). The results showed that FMA or MSS would be the best choice for evaluating the functional improvement in stroke studies on robotic upper-extremity training with high responsiveness and good correlation with ARAT. MAS could be used separately to evaluate the spasticity changes after intervention in terms of high responsiveness.
Maia, Joaquim; Rodríguez-Bernaldo de Quirós, Ana; Sendón, Raquel; Cruz, José Manuel; Seiler, Annika; Franz, Roland; Simoneau, Catherine; Castle, Laurence; Driffield, Malcolm; Mercea, Peter; Oldring, Peter; Tosa, Valer; Paseiro, Perfecto
2016-01-01
The mass transport process (migration) of a model substance, benzophenone (BZP), from LDPE into selected foodstuffs at three temperatures was studied. A mathematical model based on Fick's Second Law of Diffusion was used to simulate the migration process and a good correlation between experimental and predicted values was found. The acquired results contribute to a better understanding of this phenomenon and the parameters so-derived were incorporated into the migration module of the recently launched FACET tool (Flavourings, Additives and Food Contact Materials Exposure Tool). The migration tests were carried out at different time-temperature conditions, and BZP was extracted from LDPE and analysed by HPLC-DAD. With all data, the parameters for migration modelling (diffusion and partition coefficients) were calculated. Results showed that the diffusion coefficients (within both the polymer and the foodstuff) are greatly affected by the temperature and food's physical state, whereas the partition coefficient was affected significantly only by food characteristics, particularly fat content.
Ciais, Grégoire; Klouche, Shahnaz; Fournier, Alexandre; Rousseau, Benoit; Bauer, Thomas; Hardy, Philippe
2016-08-01
The prevalence of combined humeral and glenoid defects varies between 79 and 84 % in case of chronic posttraumatic anterior shoulder instability. The main goal of this study was to evaluate the relationship between humeral and glenoid defects based on quantitative radiological criteria. A retrospective study was performed between 2000 and 2011 including patients who underwent primary surgical shoulder stabilization for chronic posttraumatic anterior shoulder instability, with bone defects in both the glenoid and humerus and a healthy contralateral shoulder. The following measurements were taken: D/R ratio (Hill-Sachs lesion depth/humeral head radius) on an AP X-ray in internal rotation and the D1/D2 ratio [diameter of the involved glenoid articular surfaces (D1)/the healthy one (D2)] on a comparative Bernageau glenoid profile view. Measurements were taken by two observers. Correlations were determined by the Spearman correlation coefficients (r), Bland and Altman diagrams, and intra-class correlation coefficients (ICC). A sample size calculation was done. Thirty patients were included, 25 men/5 women, mean age 29.8 ± 11.2 years. The mean D/R was 23 ± 12 % for observer 1 and 23 ± 10 % for observer 2. The mean D1/D2 was 95 ± 4 % for observer 1 and 94 ± 6 % for observer 2. No significant correlation was found between humeral and glenoid bone defects by observer 1 (r = 0.23, p = 0.22) or observer 2 (r = 0.05, p = 0.78). Agreement of the observers for the D/R ratio was excellent (ICC = 0.89 ± 0.04, p < 0.00001) and good for the D1/D2 ratio (ICC = 0.54 ± 0.14, p = 0.006). Humeral and glenoid bone defects were not correlated. Inter-observer reliability was excellent for the D/R ratio and good for the D1/D2 ratio. Nonconsecutive Patients, Diagnostic Study, Level III.
NASA Astrophysics Data System (ADS)
Makungo, Rachel; Odiyo, John O.
2017-08-01
This study was focused on testing the ability of a coupled linear and non-linear system identification model in estimating groundwater levels. System identification provides an alternative approach for estimating groundwater levels in areas that lack data required by physically-based models. It also overcomes the limitations of physically-based models due to approximations, assumptions and simplifications. Daily groundwater levels for 4 boreholes, rainfall and evaporation data covering the period 2005-2014 were used in the study. Seventy and thirty percent of the data were used to calibrate and validate the model, respectively. Correlation coefficient (R), coefficient of determination (R2), root mean square error (RMSE), percent bias (PBIAS), Nash Sutcliffe coefficient of efficiency (NSE) and graphical fits were used to evaluate the model performance. Values for R, R2, RMSE, PBIAS and NSE ranged from 0.8 to 0.99, 0.63 to 0.99, 0.01-2.06 m, -7.18 to 1.16 and 0.68 to 0.99, respectively. Comparisons of observed and simulated groundwater levels for calibration and validation runs showed close agreements. The model performance mostly varied from satisfactory, good, very good and excellent. Thus, the model is able to estimate groundwater levels. The calibrated models can reasonably capture description between input and output variables and can, thus be used to estimate long term groundwater levels.
A New Methodology of Spatial Cross-Correlation Analysis
Chen, Yanguang
2015-01-01
Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran’s index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson’s correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China’s urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes. PMID:25993120
A new methodology of spatial cross-correlation analysis.
Chen, Yanguang
2015-01-01
Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran's index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson's correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China's urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes.
NASA Astrophysics Data System (ADS)
Wang, Gang-Jin; Xie, Chi; Chen, Shou; Yang, Jiao-Jiao; Yang, Ming-Yan
2013-09-01
In this study, we first build two empirical cross-correlation matrices in the US stock market by two different methods, namely the Pearson’s correlation coefficient and the detrended cross-correlation coefficient (DCCA coefficient). Then, combining the two matrices with the method of random matrix theory (RMT), we mainly investigate the statistical properties of cross-correlations in the US stock market. We choose the daily closing prices of 462 constituent stocks of S&P 500 index as the research objects and select the sample data from January 3, 2005 to August 31, 2012. In the empirical analysis, we examine the statistical properties of cross-correlation coefficients, the distribution of eigenvalues, the distribution of eigenvector components, and the inverse participation ratio. From the two methods, we find some new results of the cross-correlations in the US stock market in our study, which are different from the conclusions reached by previous studies. The empirical cross-correlation matrices constructed by the DCCA coefficient show several interesting properties at different time scales in the US stock market, which are useful to the risk management and optimal portfolio selection, especially to the diversity of the asset portfolio. It will be an interesting and meaningful work to find the theoretical eigenvalue distribution of a completely random matrix R for the DCCA coefficient because it does not obey the Marčenko-Pastur distribution.
Satisfaction of Nigerian stroke survivors with outpatient physiotherapy care.
Olaleye, Olubukola A; Hamzat, Talhatu K; Akinrinsade, Marvellous A
2017-01-01
To investigate the satisfaction of stroke survivors with outpatient physiotherapy care. Sixty stroke survivors were surveyed using the European Physiotherapy Treatment Outpatient Satisfaction Survey (EPTOPS). Focus group discussion (FGD) was also conducted with four stroke survivors from the same sample. Data were analyzed using the Kruskal Wallis test and Spearman's correlation coefficients at p = 0.05. FGD was transcribed and thematically analyzed. Nearly all the participants (98.3%) indicated one of good, very good, and excellent improvement in their clinical conditions with physiotherapy. Majority expressed satisfaction with their physiotherapy care, the modal response being very good (59.3%). Patients' satisfaction and socio-demographics were not significantly correlated (p > 0.05). Overarching themes from FGD were physiotherapy in stroke rehabilitation, satisfaction with physiotherapy care, cost, and lack of continuity of care as sources of dissatisfaction. Physiotherapists' demeanor was a facilitator of satisfaction. The stroke survivors were generally satisfied with outpatient physiotherapy care. However, lack of continuity and cost of care were sources of dissatisfaction among patients. Delivery of physiotherapy to stroke survivors in Nigeria should be structured to allow for continuity of care as this may enhance satisfaction. Implementation of inexpensive rehabilitation strategies may help reduce cost of physiotherapy.
Integer Solutions of Binomial Coefficients
ERIC Educational Resources Information Center
Gilbertson, Nicholas J.
2016-01-01
A good formula is like a good story, rich in description, powerful in communication, and eye-opening to readers. The formula presented in this article for determining the coefficients of the binomial expansion of (x + y)n is one such "good read." The beauty of this formula is in its simplicity--both describing a quantitative situation…
Neumann, M; Friedl, S; Meining, A; Egger, K; Heldwein, W; Rey, J F; Hochberger, J; Classen, M; Hohenberger, W; Rösch, T
2002-10-01
In most European countries, training in GI endoscopy has largely been based on hands-on acquisition of experience in patients rather than on a structured training programme. With the development of training models systematic hands-on training in a variety of diagnostic and therapeutic endoscopy techniques was achieved. Little, however, is known about methods of objectively assessing trainees' performance. We therefore developed an assessment 'score card' for upper GI endoscopy and tested it in endoscopists with various levels of experience. The aim of the study was therefore to assess interobserver variations in the evaluation of trainees. On the basis of textbook and expert opinions a consensus group of eight experienced endoscopists developed a score card for diagnostic upper GI endoscopy with biopsy. The score card includes an assessment of the single steps of the procedure as well as of the times needed to complete each step. This score card was then evaluated in a further conference including ten experts who blindly assessed videotapes of 15 endoscopists performing upper GI endoscopy in a training bio-simulation model (the 'Erlangen Endo-Trainer'). On the basis of their previous experience (i. e. the number of endoscopies performed) these 15 endoscopists were classified into four groups: very experienced, experienced, having some experience and inexperienced. Interobserver variability (IOV) was tested for the various score card parameters (Kendall's rank-correlation coefficient 0.0-0.5 poor, 0.5-1.0 good agreement). In addition, the correlation between the score card assessment and the examiners' experience levels was analysed. Despite poor IOV results for all the parameters tested (Kendall coefficient < 0.3), the assessment parameters correlated well when the examiners' different experience levels were taken into account (correlation coefficient 0.59-0.89, p < 0.05). The score card parameters were suitable for differentiating between the four groups of examiners with different levels of endoscopic experience. As expected with scores involving subjective assessment of performance, the variability between reviewers was substantial. Nevertheless, the assessment score was capable of distinguishing reliably between different experience levels in terms of a good individual observer consistency. The score card can therefore be used to document both training status and progress during endoscopy training courses using bio-simulation models, and this might be able to provide improved quality assurance in GI endoscopy training.
Boiling of multicomponent working fluids used in refrigeration and cryogenic systems
NASA Astrophysics Data System (ADS)
Mogorychny, V. I.; Dolzhikov, A. S.
2017-11-01
Working fluids based on mixtures are widely used in cryogenic and refrigeration engineering. One of the main elements of low-temperature units is a recuperative heat exchanger where the return flow cools the direct (cold regeneration is carrying out) resulting in continuous boiling and condensation of the multicomponent working fluid in the channels. The temperature difference between the inlet and outlet of the heat exchanger can be more than 100K, which leads to a strong change in thermophysical properties along its length. In addition, the fraction of the liquid and vapor phases in the flow varies very much, which affects the observed flow regimes in the heat exchanger channels. At the moment there are not so many experimental data and analytical correlations that would allow to estimate the heat transfer coefficient during the flow of a two-phase mixture flow at low temperatures. The work is devoted to the study of the boiling process of multicomponent working fluids used in refrigeration and cryogenic engineering. The description of the method of determination of heat transfer coefficient during boiling of mixtures in horizontal heated channel is given as well as the design of the experimental stand allowing to make such measurements. This stand is designed on the basis of a refrigeration unit operating on the Joule-Thomson throttle cycle and makes it possible to measure the heat transfer coefficient with a good accuracy. Also, the calculated values of the heat transfer coefficient, obtained with the use of various correlations, are compared with the existing experimental data. Knowing of the heat transfer coefficient will be very useful in the design of heat exchangers for low-temperature units operating on a mixture refrigerant.
Ranjan, Manish; Boutet, Alexandre; Xu, David S; Lozano, Christopher S; Kumar, Rajeev; Fasano, Alfonso; Kucharczyk, Walter; Lozano, Andres M
2018-05-30
The visualization of the subthalamic nucleus (STN) on magnetic resonance imaging (MRI) is variable. Studies of the contribution of patient-related factors and intrinsic brain volumetrics to STN visualization have not been reported previously. To assess the visualization of the STN during deep brain stimulation (DBS) surgery in a clinical setting. Eighty-two patients undergoing pre-operative MRI to plan for STN DBS for Parkinson disease were retrospectively studied. The visualization of the STN and its borders was assessed and scored by 3 independent observers using a 4-point ordinal scale (from 0 = not seen to 3 = excellent visualization). This measure was then correlated with the patients' clinical information and brain volumes. The mean STN visualization scores were 1.68 and 1.63 for the right and left STN, respectively, with a good interobserver reliability (intraclass correlation coefficient: 0.744). Older age and decreased white matter volume were negatively correlated with STN visualization (p < 0.05). STN visualization is only fair to good on routine MRI with good concordance of interindividual rating. Advancing age and decreased white matter are associated with poor visualization of the STN. Knowledge about factors contributing to poor visualization of the STN could alert a surgeon to modify the imaging strategy to optimize surgical targeting. © 2018 S. Karger AG, Basel.
First quality score for referral letters in gastroenterology—a validation study
Eskeland, Sigrun Losada; Brunborg, Cathrine; Seip, Birgitte; Wiencke, Kristine; Hovde, Øistein; Owen, Tanja; Skogestad, Erik; Huppertz-Hauss, Gert; Halvorsen, Fred-Arne; Garborg, Kjetil; Aabakken, Lars; de Lange, Thomas
2016-01-01
Objective To create and validate an objective and reliable score to assess referral quality in gastroenterology. Design An observational multicentre study. Setting and participants 25 gastroenterologists participated in selecting variables for a Thirty Point Score (TPS) for quality assessment of referrals to gastroenterology specialist healthcare for 9 common indications. From May to September 2014, 7 hospitals from the South-Eastern Norway Regional Health Authority participated in collecting and scoring 327 referrals to a gastroenterologist. Main outcome measure Correlation between the TPS and a visual analogue scale (VAS) for referral quality. Results The 327 referrals had an average TPS of 13.2 (range 1–25) and an average VAS of 4.7 (range 0.2–9.5). The reliability of the score was excellent, with an intra-rater intraclass correlation coefficient (ICC) of 0.87 and inter-rater ICC of 0.91. The overall correlation between the TPS and the VAS was moderate (r=0.42), and ranged from fair to substantial for the various indications. Mean agreement was good (ICC=0.47, 95% CI (0.34 to 0.57)), ranging from poor to good. Conclusions The TPS is reliable, objective and shows good agreement with the subjective VAS. The score may be a useful tool for assessing referral quality in gastroenterology, particularly important when evaluating the effect of interventions to improve referral quality. PMID:27855107
Sonderer, Patrizia; Akhbari Ziegler, Schirin; Gressbach Oertle, Barbara; Meichtry, André; Hadders-Algra, Mijna
2017-07-01
Pediatric physical therapy (PPT) is characterized by heterogeneity. This blurs the evaluation of effective components of PPT. The Groningen Observation Protocol (GOP) was developed to quantify contents of PPT. This study assesses the reliability and completeness of the GOP. Sixty infant PPT sessions were video-taped. Two random samples of 10 videos were used to determine interrater and intrarater reliability using interclass correlation coefficients (ICCs) with 95% confidence intervals. Completeness of GOP 2.0 was based on 60 videos. Interrater reliability of quantifying PPT actions was excellent (ICC, 0.75-1.0) in 71% and sufficient to good (ICC, 0.4-0.74) in 24% of PPT actions. Intrarater reliability was excellent in 94% and sufficient to good in 6% of PPT actions. Completeness was good for greater than 90% of PPT actions. GOP 2.0 has good reliability and completeness. After appropriate training, it is a useful tool to quantify PPT for children with developmental disorders.
Noormohammadpour, Pardis; Tavana, Bahareh; Mansournia, Mohammad Ali; Zeinalizadeh, Mehdi; Mirzashahi, Babak; Rostami, Mohsen; Kordi, Ramin
2018-05-01
Translation and cultural adaptation of the National Institutes of Health (NIH) Task Force's minimal dataset. The purpose of this study was to evaluate validity and reliability of the Farsi version of NIH Task Force's recommended multidimensional minimal dataset for research on chronic low back pain (CLBP). Considering the high treatment cost of CLBP and its increasing prevalence, NIH Pain Consortium developed research standards (including recommendations for definitions, a minimum dataset, and outcomes' report) for studies regarding CLBP. Application of these recommendations could standardize research and improve comparability of different studies in CLBP. This study has three phases: translation of dataset into Farsi and its cultural adaptation, assessment of pre-final version of dataset's comprehensibility via a pilot study, and investigation of the reliability and validity of final version of translated dataset. Subjects were 250 patients with CLBP. Test-retest reliability, content validity, and convergent validity (correlations among different dimensions of dataset and Farsi versions of Oswestry Disability Index, Roland Morris Disability Questionnaire, Fear-Avoidance Belief Questionnaire, and Beck Depression Inventory-II) were assessed. The Farsi version demonstrated good/excellent convergent validity (the correlation coefficient between impact dimension and ODI was r = 0.75 [P < 0.001], between impact dimension and Roland-Morris Disability Questionnaire was r = 0.80 [P < 0.001], and between psychological dimension and BDI was r = 0.62 [P < 0.001]). The test-retest reliability was also strong (intraclass correlation coefficient value ranged between 0.70 and 0.95) and the internal consistency was good/excellent (Chronbach's alpha coefficients' value for two main dimensions including impact dimension and psychological dimension were 0.91 and 0.82 [P < 0.001], respectively). In addition, its face validity and content validity were acceptable. The Farsi version of minimal dataset for research on CLBP is a reliable and valid instrument for data gathering in patients with CLBP. This minimum dataset can be a step toward standardization of research regarding CLBP. 3.
Mehta, S. N.; Nansel, T. R.; Volkening, L. K.; Butler, D. A.; Haynie, D. L.; Laffel, L. M. B.
2016-01-01
Aims To evaluate the psychometric properties of the Diabetes Management Questionnaire, a brief, self-report measure of adherence to contemporary diabetes management for young people with Type 1 diabetes and their caregivers. Methods A total of 273 parent-child dyads completed parallel versions of the Diabetes Management Questionnaire. Eligible children (aged 8–18 years) had Type 1 diabetes for ≥1 year. A multidisciplinary team designed the Diabetes Management Questionnaire as a brief, self-administered measure of adherence to Type 1 diabetes management over the preceding month; higher scores reflect greater adherence. Psychometrics were evaluated for the entire sample and according to age of the child. Results The children (49% female) had a mean ± SD (range) age 13.3 ± 2.9 (8–18) years and their mean ± SD HbA1c was 71 ± 15 mmol/mol (8.6 ± 1.4%). Internal consistency was good for parents (α = 0.83) and children (a = 0.79). Test-retest reliability was excellent for parents (intraclass correlation coefficient =0.83) and good for children (intraclass correlation coefficient = 0.65). Parent and child scores had moderate agreement (intraclass correlation coefficient = 0.54). Diabetes Management Questionnaire scores were inversely associated with HbA1c (parents: r = –0.41, P < 0.0001; children: r = –0.27, P < 0.0001). Psychometrics were stronger in the children aged ≥13 years compared with those aged < 13 years, but were acceptable in both age groups. Mean ± SD Diabetes Management Questionnaire scores were higher among children who were receiving insulin pump therapy (n = 181) than in children receiving multiple daily injections (n = 92) according to parent (75.9 ± 11.8 vs. 70.5 ± 15.5; P = 0.004) and child report (72.2 ± 12.1 vs. 67.6 ± 13.9; P = 0.006). Conclusions The Diabetes Management Questionnaire is a brief, valid self-report measure of adherence to contemporary diabetes self-management for people aged 8–18 years who are receiving either multiple daily injections or insulin pump therapy. PMID:26280463
A Psychometric Analysis of Quality of Life Tools in Lung Cancer Patients Who Smoke
Browning, Kristine K.; Ferketich, Amy K.; Otterson, Gregory A.; Reynolds, Nancy R.; Wewers, Mary Ellen
2009-01-01
Lung cancer is the leading cause of cancer death for both men and women in the United States. Patient quality of life (QOL) prior to cancer treatment is known to be a strong predictor of survival and toleration of treatment toxicities. A lung cancer patient’s self-assessment of QOL is highly valued among clinicians as it guides treatment-related decisions and impacts clinical outcomes. Smokers are known to report a lower QOL. Limited research has been conducted on QOL outcomes in lung cancer patients who continue to smoke. To assess QOL, a reliable and valid QOL measure specific to lung cancer is required. The Functional Assessment of Cancer Therapy-Lung Cancer (FACT-L) and Lung Cancer Symptom Scale (LCSS) are instruments that specifically examine QOL among lung cancer patients. The LCSS is a focused QOL instrument that includes physical and functional domains of QOL and disease symptomatology. The FACT-L is a broader QOL instrument that includes physical, functional, social and emotional domains and disease symptomatology. Both are psychometrically valid and are widely used in the literature, but have not been exclusively evaluated in smokers. Furthermore, there is no ‘gold standard’ instrument since there has never been a correlation study to compare estimates of reliability and validity between these instruments. The purpose of this study is to report the internal consistency and convergence validity of the FACT-L and the LCSS among newly diagnosed lung cancer patients who smoke. This data were collected and analyzed from a larger study examining smoking behavior among newly diagnosed lung cancer patients (n=51). Descriptive statistics were calculated on the FACT-L and LCSS scores, internal consistency was assessed by estimating Cronbach’s alpha coefficients, and Pearson correlation coefficients were estimated between the two scales. Internal consistency coefficients demonstrated good reliability for both scales, and the two instruments demonstrated a strong correlation, suggesting good convergence validity. Either of these instruments are appropriate measures for QOL in lung cancer patients who smoke. Given the conceptual difference between the two instruments, it is important to carefully consider the research aims when selecting the appropriate QOL measurement instrument. PMID:19181418
New Internet search volume-based weighting method for integrating various environmental impacts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ji, Changyoon, E-mail: changyoon@yonsei.ac.kr; Hong, Taehoon, E-mail: hong7@yonsei.ac.kr
Weighting is one of the steps in life cycle impact assessment that integrates various characterized environmental impacts as a single index. Weighting factors should be based on the society's preferences. However, most previous studies consider only the opinion of some people. Thus, this research proposes a new weighting method that determines the weighting factors of environmental impact categories by considering public opinion on environmental impacts using the Internet search volumes for relevant terms. To validate the new weighting method, the weighting factors for six environmental impacts calculated by the new weighting method were compared with the existing weighting factors. Themore » resulting Pearson's correlation coefficient between the new and existing weighting factors was from 0.8743 to 0.9889. It turned out that the new weighting method presents reasonable weighting factors. It also requires less time and lower cost compared to existing methods and likewise meets the main requirements of weighting methods such as simplicity, transparency, and reproducibility. The new weighting method is expected to be a good alternative for determining the weighting factor. - Highlight: • A new weighting method using Internet search volume is proposed in this research. • The new weighting method reflects the public opinion using Internet search volume. • The correlation coefficient between new and existing weighting factors is over 0.87. • The new weighting method can present the reasonable weighting factors. • The proposed method can be a good alternative for determining the weighting factors.« less
Development of the Assessment of Belief Conflict in Relationship-14 (ABCR-14)
Kyougoku, Makoto; Teraoka, Mutsumi; Masuda, Noriko; Ooura, Mariko; Abe, Yasushi
2015-01-01
Purpose Nurses and other healthcare workers frequently experience belief conflict, one of the most important, new stress-related problems in both academic and clinical fields. Methods In this study, using a sample of 1,683 nursing practitioners, we developed The Assessment of Belief Conflict in Relationship-14 (ABCR-14), a new scale that assesses belief conflict in the healthcare field. Standard psychometric procedures were used to develop and test the scale, including a qualitative framework concept and item-pool development, item reduction, and scale development. We analyzed the psychometric properties of ABCR-14 according to entropy, polyserial correlation coefficient, exploratory factor analysis, confirmatory factor analysis, average variance extracted, Cronbach’s alpha, Pearson product-moment correlation coefficient, and multidimensional item response theory (MIRT). Results The results of the analysis supported a three-factor model consisting of 14 items. The validity and reliability of ABCR-14 was suggested by evidence from high construct validity, structural validity, hypothesis testing, internal consistency reliability, and concurrent validity. The result of the MIRT offered strong support for good item response of item slope parameters and difficulty parameters. However, the ABCR-14 Likert scale might need to be explored from the MIRT point of view. Yet, as mentioned above, there is sufficient evidence to support that ABCR-14 has high validity and reliability. Conclusion The ABCR-14 demonstrates good psychometric properties for nursing belief conflict. Further studies are recommended to confirm its application in clinical practice. PMID:26247356
Sampogna, F; Linder, D; Romano, G V; Gualberti, G; Merolla, R; di Luzio Paparatti, U
2015-04-01
The Psodisk is a 10-item visual instrument, aimed at measuring the burden of psoriasis on patients. To validate the Psodisk in a large sample of patients with psoriasis, and to define categories for the interpretation of the scores. Data were collected in 21 dermatological centres. The Psodisk was administered at baseline (t0), after 2 or 3 days (t1) and about 3 months (t2) after baseline, and data were used to assess validity and reliability of the instrument. The cut-off scores were determined using the perception of the severity of the disease by the patient as anchor point. The evaluable population consisted of 320 patients at baseline, with a mean Psodisk score of 36.9. The concurrent validity of the instrument was confirmed by the high correlation with Skindex-29 and DLQI. Factor analyses selected a single factor, which alone explained almost 60% of the variance. Cronbach's coefficient alpha was 0.927, suggesting a good reliability. Test-retest reliability was verified by a Pearson's correlation coefficient between the Psodisk scores at baseline and t1 of 0.924. Five categories of disease burden were defined: 1. minimal (<9); 2. mild (9-15); 3. moderate (16-30); 4. marked (31-50); 5. severe (>50). The Psodisk showed good psychometric properties. The definition of the cut-off scores will be useful to evaluate the burden of psoriasis on patients. © 2014 European Academy of Dermatology and Venereology.
Fecal Fat Analyses in Chronic Pancreatitis Importance of Fat Ingestion before Stool Collection
Engjom, Trond; Jurmy, Palwasha; Tjora, Erling; Gilja, Odd Helge; Dimcevski, Georg
2017-01-01
Objective Quantitative determination of fecal fat still is the gold standard for measuring malabsorption. We evaluated the importance of standardized food intake before and under the collection of feces. Material and Methods In a project, evaluating patients with suspected chronic pancreatitis (CP) and healthy volunteers (HC), stools were collected for 72 hours coupled to registration of nutritional intake over five consecutive days. Patient groups were created by a modified Layer score, which includes imaging findings, clinical parameters and pancreas function testing. Results We found 12 patients with CP, 11 patients without CP and 13 healthy individuals in our database. Median fecal fat in CP patients was 12 g/day, in non-CP patients 5 g/day and in healthy controls 5 g/day. Median fat absorption coefficient was 81% in those with chronic pancreatitis, 92% in those without CP and 92% in healthy controls. Corresponding median fat intake was 65 g/day, 68 g/day and 81 g/day in the respective groups. Spearman Rank Order Correlation between fecal fat (g/d) and fat absorption coefficient in all study subjects (n = 36) was good (-0.88 (p<0.001)). When we stratified groups according to fat intake, correlation between fecal fat and fat absorption was also good (-0.86 to -0.95). Conclusion In the diagnoses of fat malabsorption, calculating the ratio of fat absorption did not give additional information compared to fecal fat. PMID:28095460
Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin
2009-05-01
There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were <10%. Interobserver and intraobserver reproducibility in left renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.
Demoulin, Christophe; Brasseur, Pauline; Roussel, Nathalie; Brereton, Clara; Humblet, Fabienne; Flynn, Daniel; Van Beveren, Julien; Osinsky, Thomas; Donneau, Anne-Françoise; Crielaard, Jean-Michel; Vanderthommen, Marc; Bruyère, Olivier
2017-11-01
Pain physiology education is an important component in the management of patients with chronic musculoskeletal pain. The Neurophysiology of Pain Questionnaire (NPQ) was developed in English to assess pain physiology knowledge in patients. This study aimed to translate the NPQ into French (NPQ-Fr) and to investigate the main psychometric properties of the NPQ-Fr. The translation was performed using the best practice translation guidelines. One hundred and one French-speaking patients with chronic non-specific spinal pain completed the NPQ-Fr to assess its acceptability and presence of floor/ceiling effects and test its dimensionality. The construct validity was tested by comparing the patients' NPQ-Fr scores to those of 17 physiotherapists and investigating its correlation with subscales of the Short Form-36 questionnaire. The reliability (i.e., internal consistency and test-retest reliability) was also investigated. To test the test-retest reliability, 70 patients were asked to complete the NPQ-Fr twice with one week in between. Regarding the NPQ-Fr psychometric properties: 1) acceptability was good; 2) internal consistency reached a Cronbach α-coefficient of 0.44; 3) no floor and ceiling effects were observed in patients; 4) a principal factor analysis generated three major factors; 5) construct validity was good; and 6) reliability was acceptable (intraclass correlation coefficient = 0.644; standard error of measurement = 1.5). The NPQ-Fr has satisfactory basic psychometric properties in patients with chronic spinal pain.
Yamato, Susumu; Shinohara, Kumiko; Nakagawa, Saori; Kubota, Ai; Inamura, Katsushi; Watanabe, Gen; Hirayama, Satoshi; Miida, Takashi; Ohta, Shin
2009-01-01
We developed and validated a sensitive and convenient high-performance liquid chromatography (HPLC) method for the specific determination of ketone bodies (acetoacetate and D-3-hydroxybutyrate) in human plasma. p-Nitrobenzene diazonium fluoroborate (diazo reagent) was used as a precolumn derivatization agent, and 3-(2-hydroxyphenyl) propionic acid was used as an internal standard. After the reaction, excess diazo reagent and plasma proteins were removed by passing through a solid-phase cartridge (C(18)). The derivatives retained on the cartridge were eluted with methanol, introduced into the HPLC system, and then detected with UV at 380 nm. A calibration curve for acetoacetate standard solution with a 20-microl injection volume showed good linearity in the range of 1 to 400 microM with a 0.9997 correlation coefficient. For the determination of D-3-hydroxybutyrate, it was converted to acetoacetate before reaction with the diazo reagent by an enzymatic coupling method using D-3-hydroxybutyrate dehydrogenase and lactate dehydrogenase. A calibration curve for D-3-hydroxybutyrate standard solution also showed good linearity in the range of 1.5 to 2000 microM with a 0.9988 correlation coefficient. Analytical recoveries of acetoacetate and D-3-hydroxybutyrate in human plasma were satisfactory. The method was successfully applied to samples from diabetic patients, and results were consistent with those obtained using the thio-NAD enzymatic cycling method used in clinical laboratories.
Sohrabi, Zohreh; Kheirkhah, Masoomeh; Sahebzad, Elahe Sadegi; Rasoulighasemlouei, Seyedehsahel; Khavandi, Siamak
2016-01-01
Background: Self-efficacy is believe in and feeling of ability to complete work. One of these factors is educational teachers’ role. This study aimed to determine relationship between teachers’ leadership style and students’ self-efficacy in midwifery students. Method: This Study is a cross sectional correlation study. Sampling was conducted in midwifery students in Bachelor Science degree in 2013. Data collection tools were multi leadership questionnaire and self-efficacy clinical performance. After explaining the goals of study, 97 students completed the questionnaire. Scoring the questionnaire was based on a Liker’s scale (0-5). Data were analyzed by SPSS 16. Correlation coefficient test was adopted to investigate the relationship and p value was considered 0.05. Result: Mean of self-efficacy scores were 116.12 (24.66.). In 53.3% of the cases, self-efficacy was good, in 42.2% moderate and in 4.3%, it was bad. The majority of the students (88.9%) reported that their teachers had an idealized style in leadership. About 94.6% of the students with good self- efficacy believed that their teachers’ leadership style was transformational style. There was a significant correlation between self- efficacy and leadership style (p<0.05). Conclusions: Results showed that transformational style is appropriate for midwifery teachers. PMID:26925916
Sohrabi, Zohreh; Kheirkhah, Masoomeh; Sahebzad, Elahe Sadegi; Rasoulighasemlouei, Seyedehsahel; Khavandi, Siamak
2015-12-18
Self-efficacy is believe in and feeling of ability to complete work. One of these factors is educational teachers ' role. This study aimed to determine relationship between teachers' leadership style and students' self-efficacy in midwifery students. This Study is a cross sectional correlation study. Sampling was conducted in midwifery students in Bachelor Science degree in 2013. Data collection tools were multi leadership questionnaire and self-efficacy clinical performance. After explaining the goals of study, 97 students completed the questionnaire. Scoring the questionnaire was based on a Liker's scale (0-5).Data were analyzed by SPSS 16. Correlation coefficient test was adopted to investigate the relationship and p value was considered 0.05. Mean of self-efficacy scores were 116.12 (24.66.). In 53.3% of the cases, self-efficacy was good, in 42.2% moderate and in 4.3%, it was bad. The majority of the students (88.9%) reported that their teachers had an idealized style in leadership. About 94.6% of the students with good self- efficacy believed that their teachers' leadership style was transformational style. There was a significant correlation between self- efficacy and leadership style (p<0.05). Results showed that transformational style is appropriate for midwifery teachers.
NASA Astrophysics Data System (ADS)
Iyahraja, S.; Rajadurai, J. Selwin; Rajesh, S.; Pandian, R. Seeni Thangaraj; Kumaran, M. Selva; Selvakumar, G.
2018-07-01
In the present study, performance of convective heat transfer and friction factor of silver-water nanofluids in a horizontal circular pipe under turbulent flow were investigated experimentally under uniform heat flux condition. The volume concentration of silver nanoparticles is varied as 0.01, 0.05 and 0.1%. Heat transfer coefficient and friction factor of nanofluids were measured experimentally by varying the Reynolds number from 3000 to 21,000. It is observed that the addition of even low volume fraction of silver nanoparticles increases both Nusselt number and heat transfer coefficient of the nanofluid significantly. Nusselt number of silver-water nanofluid increases up to 32.6% for 0.1% volume fraction at Reynolds number of 21,000. However, the addition of nanoparticles in the base fluid increases the friction factor slightly. New empirical correlations are also proposed for the estimation of Nusselt number and friction factor of silver-water nanofluid based on the data of present experimental investigation. The proposed correlations of Nusselt number and friction factor show good agreement with their experimental data.
Kurtz, J E; Lee, P A; Sherker, J L
1999-06-01
This study examines the internal consistency and temporal stability of informant ratings from two widely used instruments for normal personality assessment, the revised NEO Personality Inventory (NEO PI-R) and the Interpersonal Adjective Scales (IAS). Well-known adult targets were selected by 109 undergraduate students and rated on two occasions separated by a 6-month interval. With few exceptions, estimates of internal consistency are adequate to good for both instruments. NEO PI-R domain scores yield coefficient alphas ranging from .89 to .96, with a median of .80 for the 30 facet scales. IAS octant scales show coefficient alphas ranging from .83 to .92. Retest Pearson correlations are above .70 for each of the NEO PI-R domain scores and both IAS axis coordinates, and intraclass correlations are above .60 for all scales from both instruments. Score changes were small but statistically significant for three of the five NEO PI-R domains at retest. The retest stability of IAS type classifications varies as a function of the extremity of the associated octant scores.
NASA Astrophysics Data System (ADS)
Iyahraja, S.; Rajadurai, J. Selwin; Rajesh, S.; Pandian, R. Seeni Thangaraj; Kumaran, M. Selva; Selvakumar, G.
2018-02-01
In the present study, performance of convective heat transfer and friction factor of silver-water nanofluids in a horizontal circular pipe under turbulent flow were investigated experimentally under uniform heat flux condition. The volume concentration of silver nanoparticles is varied as 0.01, 0.05 and 0.1%. Heat transfer coefficient and friction factor of nanofluids were measured experimentally by varying the Reynolds number from 3000 to 21,000. It is observed that the addition of even low volume fraction of silver nanoparticles increases both Nusselt number and heat transfer coefficient of the nanofluid significantly. Nusselt number of silver-water nanofluid increases up to 32.6% for 0.1% volume fraction at Reynolds number of 21,000. However, the addition of nanoparticles in the base fluid increases the friction factor slightly. New empirical correlations are also proposed for the estimation of Nusselt number and friction factor of silver-water nanofluid based on the data of present experimental investigation. The proposed correlations of Nusselt number and friction factor show good agreement with their experimental data.
[Transcultural adaptation of the Antifat Attitudes Test to Brazilian Portuguese].
Obara, Angélica Almeida; Alvarenga, Marle Dos Santos
2018-05-01
Obese individuals are often blamed for their own condition and the targets of discrimination and prejudice. The scope of this study is to describe the cross-cultural adaptation to Brazilian Portuguese and the validation of the Antifat Attitudes Test - specifically developed for evaluation of negative attitudes toward the obese individual. The scale has 34 statements distributed in three subscales - Social/Character Disparagement (15 items), Physical/Romantic Unattractiveness (10 items) and Weight Control/Blame (9 items). The method involved the translation of the scale; evaluation of the conceptual, operational and item equivalence; evaluation of the semantic equivalence using the paired t test, the Pearson correlation coefficient and the intraclass correlation coefficient (ICC); internal consistency evaluation (Cronbach's alpha) and test-retest reliability (ICC) and Confirmatory Factor Analysis - after application in 340 college students in the area of health. The results showed good global internal consistency and reliability (α 0.85; CCI 0.83), and factor analysis showed that the original subscales can be kept in the adaptation, and therefore the scale adapted to the Brazilian-Portuguese version is valid and useful in studies to explore negative attitudes toward obese individuals.
A pilot study of river flow prediction in urban area based on phase space reconstruction
NASA Astrophysics Data System (ADS)
Adenan, Nur Hamiza; Hamid, Nor Zila Abd; Mohamed, Zulkifley; Noorani, Mohd Salmi Md
2017-08-01
River flow prediction is significantly related to urban hydrology impact which can provide information to solve any problems such as flood in urban area. The daily river flow of Klang River, Malaysia was chosen to be forecasted in this pilot study which based on phase space reconstruction. The reconstruction of phase space involves a single variable of river flow data to m-dimensional phase space in which the dimension (m) is based on the optimal values of Cao method. The results from the reconstruction of phase space have been used in the forecasting process using local linear approximation method. From our investigation, river flow at Klang River is chaotic based on the analysis from Cao method. The overall results provide good value of correlation coefficient. The value of correlation coefficient is acceptable since the area of the case study is influence by a lot of factors. Therefore, this pilot study may be proposed to forecast daily river flow data with the purpose of providing information about the flow of the river system in urban area.
Rex, J H; Hanson, L H; Amantea, M A; Stevens, D A; Bennett, J E
1991-01-01
An improved bioassay for fluconazole was developed. This assay is sensitive in the clinically relevant range (2 to 40 micrograms/ml) and analyzes plasma, serum, and cerebrospinal fluid specimens; bioassay results correlate with results obtained by high-pressure liquid chromatography (HPLC). Bioassay and HPLC analyses of spiked plasma, serum, and cerebrospinal fluid samples (run as unknowns) gave good agreement with expected values. Analysis of specimens from patients gave equivalent results by both HPLC and bioassay. HPLC had a lower within-run coefficient of variation (less than 2.5% for HPLC versus less than 11% for bioassay) and a lower between-run coefficient of variation (less than 5% versus less than 12% for bioassay) and was more sensitive (lower limit of detection, 0.1 micrograms/ml [versus 2 micrograms/ml for bioassay]). The bioassay is, however, sufficiently accurate and sensitive for clinical specimens, and its relative simplicity, low sample volume requirement, and low equipment cost should make it the technique of choice for analysis of routine clinical specimens. PMID:1854166
Roberts, M J; Gale, T C E; Sice, P J A; Anderson, I R
2013-06-01
Selection to specialty training is a high-stakes assessment demanding valuable consultant time. In one initial entry level and two higher level anaesthesia selection centres, we investigated the feasibility of using staff participating in simulation scenarios, rather than observing consultants, to rate candidate performance. We compared participant and observer scores using four different outcomes: inter-rater reliability; score distributions; correlation of candidate rankings; and percentage of candidates whose selection might be affected by substituting participants' for observers' ratings. Inter-rater reliability between observers was good (correlation coefficient 0.73-0.96) but lower between participants (correlation coefficient 0.39-0.92), particularly at higher level where participants also rated candidates more favourably than did observers. Station rank orderings were strongly correlated between the rater groups at entry level (rho 0.81, p < 0.001) but weaker at the two higher level centres (rho 0.52, p = 0.018; rho 0.58, p = 0.001). Substituting participants' for observers' ratings had less effect once scores were combined with those from other selection centre stations. Selection decisions for 0-20% of candidates could have changed, depending on the numbers of training posts available. We conclude that using participating raters is feasible at initial entry level only. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.
Soil moisture retrieval by active/passive microwave remote sensing data
NASA Astrophysics Data System (ADS)
Wu, Shengli; Yang, Lijuan
2012-09-01
This study develops a new algorithm for estimating bare surface soil moisture using combined active / passive microwave remote sensing on the basis of TRMM (Tropical Rainfall Measuring Mission). Tropical Rainfall Measurement Mission was jointly launched by NASA and NASDA in 1997, whose main task was to observe the precipitation of the area in 40 ° N-40 ° S. It was equipped with active microwave radar sensors (PR) and passive sensor microwave imager (TMI). To accurately estimate bare surface soil moisture, precipitation radar (PR) and microwave imager (TMI) are simultaneously used for observation. According to the frequency and incident angle setting of PR and TMI, we first need to establish a database which includes a large range of surface conditions; and then we use Advanced Integral Equation Model (AIEM) to calculate the backscattering coefficient and emissivity. Meanwhile, under the accuracy of resolution, we use a simplified theoretical model (GO model) and the semi-empirical physical model (Qp Model) to redescribe the process of scattering and radiation. There are quite a lot of parameters effecting backscattering coefficient and emissivity, including soil moisture, surface root mean square height, correlation length, and the correlation function etc. Radar backscattering is strongly affected by the surface roughness, which includes the surface root mean square roughness height, surface correlation length and the correlation function we use. And emissivity is differently affected by the root mean square slope under different polarizations. In general, emissivity decreases with the root mean square slope increases in V polarization, and increases with the root mean square slope increases in H polarization. For the GO model, we found that the backscattering coefficient is only related to the root mean square slope and soil moisture when the incident angle is fixed. And for Qp Model, through the analysis, we found that there is a quite good relationship between Qpparameter and root mean square slope. So here, root mean square slope is a parameter that both models shared. Because of its big influence to backscattering and emissivity, we need to throw it out during the process of the combination of GO model and Qp model. The result we obtain from the combined model is the Fresnel reflection coefficient in the normal direction gama(0). It has a good relationship with the soil dielectric constant. In Dobson Model, there is a detailed description about Fresnel reflection coefficient and soil moisture. With the help of Dobson model and gama(0) that we have obtained, we can get the soil moisture that we want. The backscattering coefficient and emissivity data used in combined model is from TRMM/PR, TMI; with this data, we can obtain gama(0); further, we get the soil moisture by the relationship of the two parameters-- gama(0) and soil moisture. To validate the accuracy of the retrieval soil moisture, there is an experiment conducted in Tibet. The soil moisture data which is used to validate the retrieval algorithm is from GAME-Tibet IOP98 Soil Moisture and Temperature Measuring System (SMTMS). There are 9 observing sites in SMTMS to validate soil moisture. Meanwhile, we use the SMTMS soil moisture data obtained by Time Domain Reflectometer (TDR) to do the validation. And the result shows the comparison of retrieval and measured results is very good. Through the analysis, we can see that the retrieval and measured results in D66 is nearly close; and in MS3608, the measured result is a little higher than retrieval result; in MS3637, the retrieval result is a little higher than measured result. According to the analysis of the simulation results, we found that this combined active and passive approach to retrieve the soil moisture improves the retrieval accuracy.
Is Diaphragm Motion a Good Surrogate for Liver Tumor Motion?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Juan; School of Information Science and Engineering, Shandong University, Jinan, Shandong; Cai, Jing
Purpose: To evaluate the relationship between liver tumor motion and diaphragm motion. Methods and Materials: Fourteen patients with hepatocellular carcinoma (10 of 14) or liver metastases (4 of 14) undergoing radiation therapy were included in this study. All patients underwent single-slice cine–magnetic resonance imaging simulations across the center of the tumor in 3 orthogonal planes. Tumor and diaphragm motion trajectories in the superior–inferior (SI), anterior–posterior (AP), and medial–lateral (ML) directions were obtained using an in-house-developed normalized cross-correlation–based tracking technique. Agreement between the tumor and diaphragm motion was assessed by calculating phase difference percentage, intraclass correlation coefficient, and Bland-Altman analysis (Diff).more » The distance between the tumor and tracked diaphragm area was analyzed to understand its impact on the correlation between the 2 motions. Results: Of all patients, the mean (±standard deviation) phase difference percentage values were 7.1% ± 1.1%, 4.5% ± 0.5%, and 17.5% ± 4.5% in the SI, AP, and ML directions, respectively. The mean intraclass correlation coefficient values were 0.98 ± 0.02, 0.97 ± 0.02, and 0.08 ± 0.06 in the SI, AP, and ML directions, respectively. The mean Diff values were 2.8 ± 1.4 mm, 2.4 ± 1.1 mm, and 2.2 ± 0.5 mm in the SI, AP, and ML directions, respectively. Tumor and diaphragm motions had high concordance when the distance between the tumor and tracked diaphragm area was small. Conclusions: This study showed that liver tumor motion had good correlation with diaphragm motion in the SI and AP directions, indicating diaphragm motion in the SI and AP directions could potentially be used as a reliable surrogate for liver tumor motion.« less
Zhang, Quan; Chen, Zheng; Chen, Shenghuo; Xu, Youyun; Deng, Huihua
2017-02-01
Cortisol, cortisone and the ratio of cortisol to cortisone in saliva, urine and hair are acute, short-term and long-term biomarkers to reliably assess the activity of hypothalamic-pituitary-adrenal (HPA) axis and 11β-hydroxysteroid dehydrogenase (11β-HSD). One key issue is whether these biomarkers have intraindividual relative stability. Salivary, urinary and hair cortisol was proven to show considerable long-term intraindividual relative stability. However, currently unknown is whether cortisone and the ratio in saliva, urine and hair show intraindividual relative stability. The present study utilized a longitudinal design to validate long-term stability within two weeks of three biomarkers in saliva and urine, and long-term stability within twelve months of three hair biomarkers. Salivary, urinary and hair steroids were measured with high performance liquid chromatography tandem mass spectrometry. Three biomarkers in urine and hair showed moderate test-retest correlations with coefficient (r) ranging between 0.22 and 0.56 and good multiple-test consistencies with coefficient of intraclass correlation (ICC) ranging between 0.42 and 0.67. Three single-point salivary biomarkers showed weak to moderate test-retest correlations (r's between 0.01 and 0.38) and poor to fair multiple-test consistencies (ICC's between 0.29 and 0.53) within two weeks. Three single-day salivary biomarkers showed moderate test-retest correlations (r's between 0.23 and 0.53) and good multiple-test consistencies (ICC's between 0.56 and 0.66) within two weeks. Three biomarkers in urine and hair showed moderate long-term intraindividual relative stability. Three single-point salivary biomarkers showed weak to moderate short-term and long-term intraindividual relative stability, but three single-day salivary biomarkers showed moderate short-term and long-term intraindividual relative stability. Copyright © 2016 Elsevier Inc. All rights reserved.
Daily Rainfall Simulation Using Climate Variables and Nonhomogeneous Hidden Markov Model
NASA Astrophysics Data System (ADS)
Jung, J.; Kim, H. S.; Joo, H. J.; Han, D.
2017-12-01
Markov chain is an easy method to handle when we compare it with other ones for the rainfall simulation. However, it also has limitations in reflecting seasonal variability of rainfall or change on rainfall patterns caused by climate change. This study applied a Nonhomogeneous Hidden Markov Model(NHMM) to consider these problems. The NHMM compared with a Hidden Markov Model(HMM) for the evaluation of a goodness of the model. First, we chose Gum river basin in Korea to apply the models and collected daily rainfall data from the stations. Also, the climate variables of geopotential height, temperature, zonal wind, and meridional wind date were collected from NCEP/NCAR reanalysis data to consider external factors affecting the rainfall event. We conducted a correlation analysis between rainfall and climate variables then developed a linear regression equation using the climate variables which have high correlation with rainfall. The monthly rainfall was obtained by the regression equation and it became input data of NHMM. Finally, the daily rainfall by NHMM was simulated and we evaluated the goodness of fit and prediction capability of NHMM by comparing with those of HMM. As a result of simulation by HMM, the correlation coefficient and root mean square error of daily/monthly rainfall were 0.2076 and 10.8243/131.1304mm each. In case of NHMM, the correlation coefficient and root mean square error of daily/monthly rainfall were 0.6652 and 10.5112/100.9865mm each. We could verify that the error of daily and monthly rainfall simulated by NHMM was improved by 2.89% and 22.99% compared with HMM. Therefore, it is expected that the results of the study could provide more accurate data for hydrologic analysis. Acknowledgements This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Science, ICT & Future Planning(2017R1A2B3005695)
Agreement between sleep diary and actigraphy in a highly educated Brazilian population.
Campanini, Marcela Zambrim; Lopez-Garcia, Esther; Rodríguez-Artalejo, Fernando; González, Alberto Durán; Andrade, Selma Maffei; Mesas, Arthur Eumann
2017-07-01
This study evaluated the agreement between a sleep diary and actigraphy on the assessment of sleep parameters among school teachers from Brazil. A total of 163 teachers (66.3% women; aged 45 ± 9 years) filled out a sleep diary and wore a wrist actigraph device for seven consecutive days. Data were collected from August 2014 to March 2015 in Londrina, a large city in southern Brazil. Intraclass correlation coefficients (ICC) and Pearson correlation coefficients (r) were used to compare self-reported and actigraphic data. Self-reported total sleep time (TST), sleep onset latency (SOL), and sleep efficiency were higher than measured by actigraphy (mean difference: 22.6 ± 46.9 min, 2.6 ± 13.3 min, and 7.3± 5.7%, respectively). Subjective total time in bed (TIB) and wake-up time were lower than measured by actigraphy (mean difference: -10.7 ± 37.6 and -19.7 ± 29.6, respectively). Moderate or good agreement and correlation were found between the sleep diary and the actigraphic data for TST (ICC = 0.70; r = 0.60), TIB (ICC = 0.83; r = 0.73), bedtime (ICC = 0.95; r = 0.91), sleep start time (ICC = 0.94; r = 0.88), and wake-up time (ICC = 0.87; r = 0.78). However, SOL (ICC = 0.49; r = 0.38) and sleep efficiency (ICC = 0.16; r = 0.22) showed only fair or poor agreement and correlation. In this highly educated population, the sleep diary and the actigraphy showed moderate or good agreement to assess several sleep parameters. However, these methods seemed to measure different dimensions of sleep regarding sleep onset latency and efficiency. These findings moderately varied according to the individual's subjective sleep quality. Copyright © 2017 Elsevier B.V. All rights reserved.
Papadopoulos, Costas; Constantinou, Antonis; Cheimonidou, Areti-Zoi; Stasinopoulos, Dimitrios
2017-04-01
To cross-culturally adapt and validate the Greek version of the Kujala anterior knee pain scale (KAKPS). The Greek KAKPS was translated from the original English version following standard forward and backward translation procedures. The survey was then conducted in clinical settings by a questionnaire comprising the Greek KAKPS and patellofemoral pain syndrome (PFPS) severity scale. A total of 130 (62 women and 68 men) Greek-reading patients between 18 and 45 years old with anterior knee pain (AKP) for at least four weeks were recruited from physical therapy clinics. To establish test-retest reliability, the patients were asked to complete the KAKPS at initial visit and 2-3 days after the initial visit. The Greek version of the PFPS severity scale was also administered once at initial visit. Internal consistency of the translated instrument was measured using Cronbach's α. An intraclass correlation coefficient was used to assess the test-retest reliability of the KAKPS. Concurrent validity was measured by correlating the KAKPS with the PFPS severity scale using Pearson's correlation coefficient. The results showed that the Greek KAKPS has good internal consistency (Cronbach's α = 0.942), test-retest reliability (ICC = 0.921) and concurrent validity (r > 0.7). This study has shown that the Greek KAKPS has good internal consistency, test-retest reliability and concurrent validity when correlated with the PFPS severity scale in adult patients with AKP for at least four weeks. Implications for rehabilitation The Greek version of the KAKPS has been found to be reliable and valid when used in adult patients with AKP for at least four weeks. The results of the psychometric characteristics were compatible with those of the original English version. The KAKPS could be applied in a Greek-speaking population to assess functional limitations and symptoms in patients aged 18-45 years old with AKP for at least four weeks.
NASA Astrophysics Data System (ADS)
Piretzidis, Dimitrios; Sra, Gurveer; Karantaidis, George; Sideris, Michael G.
2017-04-01
A new method for identifying correlated errors in Gravity Recovery and Climate Experiment (GRACE) monthly harmonic coefficients has been developed and tested. Correlated errors are present in the differences between monthly GRACE solutions, and can be suppressed using a de-correlation filter. In principle, the de-correlation filter should be implemented only on coefficient series with correlated errors to avoid losing useful geophysical information. In previous studies, two main methods of implementing the de-correlation filter have been utilized. In the first one, the de-correlation filter is implemented starting from a specific minimum order until the maximum order of the monthly solution examined. In the second one, the de-correlation filter is implemented only on specific coefficient series, the selection of which is based on statistical testing. The method proposed in the present study exploits the capabilities of supervised machine learning algorithms such as neural networks and support vector machines (SVMs). The pattern of correlated errors can be described by several numerical and geometric features of the harmonic coefficient series. The features of extreme cases of both correlated and uncorrelated coefficients are extracted and used for the training of the machine learning algorithms. The trained machine learning algorithms are later used to identify correlated errors and provide the probability of a coefficient series to be correlated. Regarding SVMs algorithms, an extensive study is performed with various kernel functions in order to find the optimal training model for prediction. The selection of the optimal training model is based on the classification accuracy of the trained SVM algorithm on the same samples used for training. Results show excellent performance of all algorithms with a classification accuracy of 97% - 100% on a pre-selected set of training samples, both in the validation stage of the training procedure and in the subsequent use of the trained algorithms to classify independent coefficients. This accuracy is also confirmed by the external validation of the trained algorithms using the hydrology model GLDAS NOAH. The proposed method meet the requirement of identifying and de-correlating only coefficients with correlated errors. Also, there is no need of applying statistical testing or other techniques that require prior de-correlation of the harmonic coefficients.
Factors That Attenuate the Correlation Coefficient and Its Analogs.
ERIC Educational Resources Information Center
Dolenz, Beverly
The correlation coefficient is an integral part of many other statistical techniques (analysis of variance, t-tests, etc.), since all analytic methods are actually correlational (G. V. Glass and K. D. Hopkins, 1984). The correlation coefficient is a statistical summary that represents the degree and direction of relationship between two variables.…
Self-perceived health in older Europeans: Does the choice of survey matter?
Croezen, Simone; Burdorf, Alex
2016-01-01
Abstract Background: Cross-national comparisons of health in European countries provide crucial information to monitor health and disease within and between countries and to inform policy and research priorities. However, variations in estimates might occur when information from cross-national European surveys with different characteristics are used. We compared the prevalence of very good or good self-perceived health across 10 European countries according to three European surveys and investigated which survey characteristics contributed to differences in prevalence estimates. Methods: We used aggregate data from 2004 to 2005 of respondents aged 55–64 years from the European Union Statistics on Income and Living Conditions (EU-SILC), the Survey of Health, Ageing and Retirement in Europe (SHARE) and the European Social Survey (ESS). Across the surveys, self-perceived health was assessed by the same question with response options ranging from very good to very bad. Results: Despite a good correlation between the surveys (intraclass correlation coefficient: 0.77), significant differences were found in prevalence estimates of very good or good self-perceived health. The survey response, sample size and survey mode contributed statistically significantly to the differences between the surveys. Multilevel linear regression analyses, adjusted for survey characteristics, showed a higher prevalence for SHARE (+6.96, 95% CIs: 3.14 to 10.8) and a lower prevalence (−3.12; 95% CIs: −7.11 to 0.86) for ESS, with EU-SILC as the reference survey. Conclusion: Three important health surveys in Europe showed substantial differences for presence of very good or good self-perceived health. These differences limit the usefulness for direct comparisons across studies in health policies for Europe. PMID:26989125
Sciatic neurosteatosis: Relationship with age, gender, obesity and height.
Ratner, Shayna; Khwaja, Raamis; Zhang, Lihua; Xi, Yin; Dessouky, Riham; Rubin, Craig; Chhabra, Avneesh
2018-04-01
To evaluate inter-reader performance for cross-sectional area and fat quantification of bilateral sciatic nerves on MRI and assess correlations with anthropometrics. In this IRB-approved, HIPPA-compliant study, three readers performed a cross-sectional analysis of 3T lumbosacral plexus MRIs over an 18-month period. Image slices were evaluated at two levels (A and B). The sciatic nerve was outlined using a free hand region of interest tool on PACS. Proton-density fat fraction (FF) and cross-sectional areas were recorded. Inter-reader agreement was assessed using intra-class correlation coefficient (ICC). Spearman correlation coefficients were used for correlations with age, BMI and height and Wilcoxon rank sum test was used to assess gender differences. A total of 67 patients were included in this study with male to female ratio of 1:1. Inter-reader agreement was good to excellent for FF measurements at both levels (ICC=0.71-0.90) and poor for sciatic nerve areas (ICC=0.08-0.27). Positive correlations of sciatic FF and area were seen with age (p value<0.05). Males had significantly higher sciatic intraneural fat than females (p<0.05). Fat quantification MRI is highly reproducible with significant positive correlations of sciatic FF and area with age, which may have implications for MRI diagnosis of sciatic neuropathy. • MR proton density fat fraction is highly reproducible at multiple levels. • Sciatic intraneural fat is positively correlated with increasing age (p < 0.05). • Positive correlations exist between bilateral sciatic nerve areas and age (p < 0.05). • Males had significantly higher sciatic intraneural fat than females (p < 0.05).
Hwang, Soonshin; Noh, Yoonjeong; Choi, Yoon Jeong; Chung, Chooryung; Lee, Hye Sun; Kim, Kyung-Ho
2018-01-01
The aim of this study was to establish the normative data of dentofacial transverse dimensions according to the skeletal maturation stage in Korean adolescents with good occlusion, assess gender differences and determine correlations between transverse variables. A total of 577 Korean subjects between ages 7 to 19 years and exhibiting skeletal Class I occlusion were categorized by skeletal maturation index (SMI) of Fishman using hand-wrist radiographs. Dentofacial transverse dimensions were assessed using posteroanterior cephalograms. Independent two-sample t -tests were used to analyze differences between genders. Pearson correlation coefficient was used to determine the correlation between transverse measurements. Dentofacial transverse norms relevant to skeletal maturation stages were established. The average maxillomandibular width difference and ratio at growth completion was 22.16 mm and 77.01% for males; 23.70 mm and 74.06% for females, respectively. Males had greater facial, maxillary and mandibular widths compared to females at every SMI stage. The maxillary and mandibular intermolar widths showed the strongest correlation for both sexes (r = 0.826 for males, r = 0.725 for females). Dentofacial transverse norms of Korean adolescents were established according to developmental stage. All dentofacial widths were greater in males at growth completion. Maxillary and mandibular intermolar widths were strongly correlated. This study may serve as a guideline for the assessment of dentofacial transverse growth according to skeletal maturation stage in Korean adolescents with good occlusion.
Sampson, J S; Wilkinson, H W; Tsang, V C; Brake, B J
1983-01-01
A semiautomated, kinetic-dependent, enzyme-linked immunosorbent assay (K-ELISA) was adapted to detect serum antibodies to Legionella pneumophila. In a comparative study, 158 human serum samples (79 pairs) were tested by K-ELISA and the standard indirect immunofluorescence assay for determination of antibody levels to L. pneumophila serogroup 1. K-ELISA determinations were made by using a serogroup-specific antigen or a preparation (unfractionated antigen) which contained both common antigen and serogroup-specific reactivity. There was good correlation between the immunofluorescence assay and the K-ELISA by using either antigen, although greater correlation was achieved with the unfractionated antigen (coefficients of correlation, 0.894 with unfractionated antigen and 0.841 with serogroup-specific antigen). These results indicate that the K-ELISA is a reliable alternative to the immunofluorescence assay for serologically diagnosing legionellosis. PMID:6361052
Sampson, J S; Wilkinson, H W; Tsang, V C; Brake, B J
1983-12-01
A semiautomated, kinetic-dependent, enzyme-linked immunosorbent assay (K-ELISA) was adapted to detect serum antibodies to Legionella pneumophila. In a comparative study, 158 human serum samples (79 pairs) were tested by K-ELISA and the standard indirect immunofluorescence assay for determination of antibody levels to L. pneumophila serogroup 1. K-ELISA determinations were made by using a serogroup-specific antigen or a preparation (unfractionated antigen) which contained both common antigen and serogroup-specific reactivity. There was good correlation between the immunofluorescence assay and the K-ELISA by using either antigen, although greater correlation was achieved with the unfractionated antigen (coefficients of correlation, 0.894 with unfractionated antigen and 0.841 with serogroup-specific antigen). These results indicate that the K-ELISA is a reliable alternative to the immunofluorescence assay for serologically diagnosing legionellosis.
Vereecken, Carine Anna; Van Damme, Wendy; Maes, Lea
2005-02-01
This article examines the reliability and construct validity of questions assessing mediating factors of fruit and vegetable consumption among 11- and 12-year-old children (N=207). Internal consistencies were good for most scales, ranging from 0.56 to 0.94. Intraclass correlation coefficients between test and retest were acceptable, ranging from 0.39 to 0.90. Concerning predictive validity, preferences and perceived parental and peer behavior were significantly associated with fruit and vegetable consumption. Self-efficacy in difficult situations and a variety of available fruit were significantly correlated with fruit consumption, while permissive eating practices and obligation rules were significantly correlated with vegetable consumption. General attitudes, outcome expectations, selection efficacy, and encouraging practices were not associated with fruit or vegetable consumption.
P-Wave to Rayleigh-wave conversion coefficients for wedge corners; model experiments
Gangi, A.F.; Wesson, R.L.
1978-01-01
An analytic solution is not available for the diffraction of elastic waves by wedges; however, numerical solutions of finite-difference type are available for selected wedge angles. The P- to Rayleigh-wave conversion coefficients at wedge tips have been measured on two-dimensional seismic models for stress-free wedges with wedge angles, ??0, of 10, 30, 60, 90 and 120??. The conversion coefficients show two broad peaks and a minimum as a function of the angle between the wedge face and the direction of the incident P-wave. The minimum occurs for the P wave incident parallel to the wedge face and one maximum is near an incidence angle of 90?? to the wedge face. The amplitude of this maximum, relative to the other, decreases as the wedge angle increases. The asymmetry of the conversion coefficients, CPR(??; ??0), relative to parallel incidence (?? = 0) increases as the wedge angle increases. The locations of the maxima and the minimum as well as the asymmetry can be explained qualitatively. The conversion coefficients are measured with an accuracy of ??5% in those regions where there are no interfering waves. A comparison of the data for the 10?? wedge with the theoretical results for a half plane (0?? wedge) shows good correlation. ?? 1978.
Chen, Hui-fang; Wu, Ching-yi; Lin, Keh-chung; Li, Ming-wei; Yu, Hung-wen
2012-07-01
To examine the measurement properties of a short version of the Stroke-Specific Quality of Life Scale (SS-QoL-12). Self-report survey of patients with mild to moderate upper extremity dysfunction. A total of 126 patients provided 252 observations before and after treatment. The construct validity and reliability was examined using the Rasch model; the concurrent and predictive validity was estimated using Spearman's rank correlation coefficients. Paired t-test and the standardized response mean (SRM) were performed to estimate the responsiveness of the SS-QoL-12. The 2-factor model (psychosocial and physical domains) fit the data better with smaller deviances. All but 1 item showed acceptable fit, and no item biases were detected. The reliability of the subscales and the whole scale ranged from 0.67 to 0.99. The total score showed fair correlations with the criterion measures at pretreatment (ρ = 0.28-0.40) and fair to good correlations at post-treatment (ρ = 0.39-0.54). The subscales had low to fair correlations at pretreatment (ρ = 0.19-0.49) and fair to good correlations at post-treatment (ρ = 0.31-0.56). The total and the subscales had low to good predictions at baseline (ρ = 0.22-0.52). The whole scale and the psychosocial subscale were mildly responsive to change (SRM = 0.22), but the physical subscale was not responsive to change (SRM = 0.08). The SS-QoL-12 has acceptable to good measurement properties, with an advantage of requiring less time to administer than other scales. The use of the subscale and total scores depends on the purpose of research. Future studies should recruit stroke patients with a broad range of dysfunction and use a large sample size to validate the findings.
Accuracy and Reliability Assessment of CT and MR Perfusion Analysis Software Using a Digital Phantom
Christensen, Soren; Sasaki, Makoto; Østergaard, Leif; Shirato, Hiroki; Ogasawara, Kuniaki; Wintermark, Max; Warach, Steven
2013-01-01
Purpose: To design a digital phantom data set for computed tomography (CT) perfusion and perfusion-weighted imaging on the basis of the widely accepted tracer kinetic theory in which the true values of cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), and tracer arrival delay are known and to evaluate the accuracy and reliability of postprocessing programs using this digital phantom. Materials and Methods: A phantom data set was created by generating concentration-time curves reflecting true values for CBF (2.5–87.5 mL/100 g per minute), CBV (1.0–5.0 mL/100 g), MTT (3.4–24 seconds), and tracer delays (0–3.0 seconds). These curves were embedded in human brain images. The data were analyzed by using 13 algorithms each for CT and magnetic resonance (MR), including five commercial vendors and five academic programs. Accuracy was assessed by using the Pearson correlation coefficient (r) for true values. Delay-, MTT-, or CBV-dependent errors and correlations between time to maximum of residue function (Tmax) were also evaluated. Results: In CT, CBV was generally well reproduced (r > 0.9 in 12 algorithms), but not CBF and MTT (r > 0.9 in seven and four algorithms, respectively). In MR, good correlation (r > 0.9) was observed in one-half of commercial programs, while all academic algorithms showed good correlations for all parameters. Most algorithms had delay-dependent errors, especially for commercial software, as well as CBV dependency for CBF or MTT calculation and MTT dependency for CBV calculation. Correlation was good in Tmax except for one algorithm. Conclusion: The digital phantom readily evaluated the accuracy and characteristics of the CT and MR perfusion analysis software. All commercial programs had delay-induced errors and/or insufficient correlations with true values, while academic programs for MR showed good correlations with true values. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112618/-/DC1 PMID:23220899
Correlation of 1.65 and 2.15 micron airglow emissions
NASA Technical Reports Server (NTRS)
Kieffaber, L. M.
1974-01-01
The intense infrared airglow is due primarily to vibration-rotation bands of the OH molecule. This airglow has been observed with a 24-in. scanning photometer at two wavelengths. Narrow-band interference filters are used to limit observations to the (9,7) band at 2.15 microns and the (4,2) and (5,3) bands at 1.65 microns. If OH emission results from creation of the excited OH molecule in the v = 9 vibrational state and subsequent cascading through lower vibrational levels, the 1.65 and 2.15 micron radiation will be well correlated in space and time. However, if several mechanisms are involved in producing OH in a variety of initial excitation levels, there is no reason to expect good correlation. Sky maps obtained simultaneously at 1.65 and 2.15 microns show strongly correlated intensity fluctuations. Quantitative analysis of these maps and other investigations of smaller areas of the sky yield correlation coefficients typically in excess of 0.8.
Correlation-study about the ambient dose rate and the weather conditions
NASA Astrophysics Data System (ADS)
Furuya, Masato; Hatano, Yuko; Aoyama, Tomoo; Igarashi, Yasuhito; Kita, Kazuyuki; Ishizuka, Masahide
2016-04-01
The long-term radiation risks are believed to be heavily affected by the resuspension process. We therefore focus on the surface-atmosphere exchange process of released radioactive materials in this study. Radioactive materials were deposited on the soil and float in the air, and such complicated process are influenced by the weather conditions deeply. We need to reveal the correlation between the weather conditions and the ambient dose rate. In this study, we study the correlation between the weather conditions and the ambient dose rate with the correction of the decrease due to the radioactive decay. We found that there is a negative correlation between the ambient dose rate and the soil water content by the correlation coefficient. Using this result, we reconstruct the ambient dose rate from the weather conditions by the multiple regression analysis and found that the reconstructed data agree with the observation very well. Using Kalman filter, which can be sequentially updates the state estimate, we obtained such a good agreement.
Jiang, Y; Dou, Y L; Cai, A J; Zhang, Z; Tian, T; Dai, J H; Huang, A L
2016-02-01
Knowledge-motivation-psychological model was set up and tested through structural equation model to provide evidence on HIV prevention related strategy in Men who have Sex with Men (MSM). Snowball sampling method was used to recruit a total of 550 MSM volunteers from two MSM Non-Governmental Organizations in Urumqi, Xinjiang province. HIV prevention related information on MSM was collected through a questionnaire survey. A total of 477 volunteers showed with complete information. HIV prevention related Knowledge-motivation-psychological model was built under related experience and literature. Relations between knowledge, motivation and psychological was studied, using a ' structural equation model' with data from the fitting questionnaires and modification of the model. Structural equation model presented good fitting results. After revising the fitting index: RMSEA was 0.035, NFI was 0.965 and RFI was 0.920. Thereafter the exogenous latent variables would include knowledge, motivation and psychological effects. The endogenous latent variable appeared as prevention related behaviors. The standardized total effects of motivation, knowledge, psychological on prevention behavior were 0.44, 0.41 and 0.17 respectively. Correlation coefficient of motivation and psychological effects was 0.16. Correlation coefficient on knowledge and psychological effects was -0.17 (P<0.05). Correlation coefficient of knowledge and motivation did not show statistical significance. Knowledge of HIV and motivation of HIV prevention did not show any accordance in MSM population. It was necessary to increase the awareness and to improve the motivation of HIV prevention in MSM population.
ppcor: An R Package for a Fast Calculation to Semi-partial Correlation Coefficients.
Kim, Seongho
2015-11-01
Lack of a general matrix formula hampers implementation of the semi-partial correlation, also known as part correlation, to the higher-order coefficient. This is because the higher-order semi-partial correlation calculation using a recursive formula requires an enormous number of recursive calculations to obtain the correlation coefficients. To resolve this difficulty, we derive a general matrix formula of the semi-partial correlation for fast computation. The semi-partial correlations are then implemented on an R package ppcor along with the partial correlation. Owing to the general matrix formulas, users can readily calculate the coefficients of both partial and semi-partial correlations without computational burden. The package ppcor further provides users with the level of the statistical significance with its test statistic.
The Predictive Value of Ultrasound Learning Curves Across Simulated and Clinical Settings.
Madsen, Mette E; Nørgaard, Lone N; Tabor, Ann; Konge, Lars; Ringsted, Charlotte; Tolsgaard, Martin G
2017-01-01
The aim of the study was to explore whether learning curves on a virtual-reality (VR) sonographic simulator can be used to predict subsequent learning curves on a physical mannequin and learning curves during clinical training. Twenty midwives completed a simulation-based training program in transvaginal sonography. The training was conducted on a VR simulator as well as on a physical mannequin. A subgroup of 6 participants underwent subsequent clinical training. During each of the 3 steps, the participants' performance was assessed using instruments with established validity evidence, and they advanced to the next level only after attaining predefined levels of performance. The number of repetitions and time needed to achieve predefined performance levels were recorded along with the performance scores in each setting. Finally, the outcomes were correlated across settings. A good correlation was found between time needed to achieve predefined performance levels on the VR simulator and the physical mannequin (Pearson correlation coefficient .78; P < .001). Performance scores on the VR simulator correlated well to the clinical performance scores (Pearson correlation coefficient .81; P = .049). No significant correlations were found between numbers of attempts needed to reach proficiency across the 3 different settings. A post hoc analysis found that the 50% fastest trainees at reaching proficiency during simulation-based training received higher clinical performance scores compared to trainees with scores placing them among the 50% slowest (P = .025). Performances during simulation-based sonography training may predict performance in related tasks and subsequent clinical learning curves. © 2016 by the American Institute of Ultrasound in Medicine.
NASA Astrophysics Data System (ADS)
Sun, Xuelian; Liu, Zixian
2016-02-01
In this paper, a new estimator of correlation matrix is proposed, which is composed of the detrended cross-correlation coefficients (DCCA coefficients), to improve portfolio optimization. In contrast to Pearson's correlation coefficients (PCC), DCCA coefficients acquired by the detrended cross-correlation analysis (DCCA) method can describe the nonlinear correlation between assets, and can be decomposed in different time scales. These properties of DCCA make it possible to improve the investment effect and more valuable to investigate the scale behaviors of portfolios. The minimum variance portfolio (MVP) model and the Mean-Variance (MV) model are used to evaluate the effectiveness of this improvement. Stability analysis shows the effect of two kinds of correlation matrices on the estimation error of portfolio weights. The observed scale behaviors are significant to risk management and could be used to optimize the portfolio selection.
NASA Technical Reports Server (NTRS)
Cohen, S. C.
1980-01-01
A technique for fitting a straight line to a collection of data points is given. The relationships between the slopes and correlation coefficients, and between the corresponding standard deviations and correlation coefficient are given.
NASA Astrophysics Data System (ADS)
Nugraha, Muhamad Gina; Kaniawati, Ida; Rusdiana, Dadi; Kirana, Kartika Hajar
2016-02-01
Among the purposes of physics learning at high school is to master the physics concepts and cultivate scientific attitude (including critical attitude), develop inductive and deductive reasoning skills. According to Ennis et al., inductive and deductive reasoning skills are part of critical thinking. Based on preliminary studies, both of the competence are lack achieved, it is seen from student learning outcomes is low and learning processes that are not conducive to cultivate critical thinking (teacher-centered learning). One of learning model that predicted can increase mastery concepts and train CTS is inquiry learning model aided computer simulations. In this model, students were given the opportunity to be actively involved in the experiment and also get a good explanation with the computer simulations. From research with randomized control group pretest-posttest design, we found that the inquiry learning model aided computer simulations can significantly improve students' mastery concepts than the conventional (teacher-centered) method. With inquiry learning model aided computer simulations, 20% of students have high CTS, 63.3% were medium and 16.7% were low. CTS greatly contribute to the students' mastery concept with a correlation coefficient of 0.697 and quite contribute to the enhancement mastery concept with a correlation coefficient of 0.603.
Brazilian version of the body dysmorphic disorder examination.
Jorge, Renata Trajano Borges; Sabino Neto, Miguel; Natour, Jamil; Veiga, Daniela Francescato; Jones, Anamaria; Ferreira, Lydia Masako
2008-03-06
Body image improvement is considered to be the main reason for undergoing plastic surgery. The objective was to translate the Body Dysmorphic Disorder Examination (BDDE) into Brazilian Portuguese and to adapt and validate this questionnaire for use in Brazil. Cross-sectional survey, at the Department of Plastic Surgery of Universidade Federal de São Paulo. The BDDE was first translated into Portuguese and then back-translated into English. These translations were then discussed by healthcare professionals in order to establish the final Brazilian version. In a second stage, the validity and reliability of the BDDE were assessed. For this, patients were initially interviewed by two interviewers and subsequently, by only one of these interviewers. On the first occasion, in addition to the BDDE, the body shape questionnaire (BSQ) and the Rosenberg self-esteem scale were also applied. These questionnaires were applied to 90 patients. Six questions were modified during the assessment of cultural equivalence. Cronbach's alpha was 0.89 and the intraclass correlation coefficients for interobserver and test-retest reliability were 0.91 and 0.87, respectively. Pearson's coefficient showed no correlation between the BDDE and the Rosenberg self-esteem scale (0.22), whereas there was a moderate correlation between the BDDE and the BSQ (0.64). The BDDE was successfully translated and adapted, with good internal consistency, reliability and construct validity.
Fundamental movement skills testing in children with cerebral palsy.
Capio, Catherine M; Sit, Cindy H P; Abernethy, Bruce
2011-01-01
To examine the inter-rater reliability and comparative validity of product-oriented and process-oriented measures of fundamental movement skills among children with cerebral palsy (CP). In total, 30 children with CP aged 6 to 14 years (Mean = 9.83, SD = 2.5) and classified in Gross Motor Function Classification System (GMFCS) levels I-III performed tasks of catching, throwing, kicking, horizontal jumping and running. Process-oriented assessment was undertaken using a number of components of the Test of Gross Motor Development (TGMD-2), while product-oriented assessment included measures of time taken, distance covered and number of successful task completions. Cohen's kappa, Spearman's rank correlation coefficient and tests to compare correlated correlation coefficients were performed. Very good inter-rater reliability was found. Process-oriented measures for running and jumping had significant associations with GMFCS, as did seven product-oriented measures for catching, throwing, kicking, running and jumping. Product-oriented measures of catching, kicking and running had stronger associations with GMFCS than the corresponding process-oriented measures. Findings support the validity of process-oriented measures for running and jumping and of product-oriented measures of catching, throwing, kicking, running and jumping. However, product-oriented measures for catching, kicking and running appear to have stronger associations with functional abilities of children with CP, and are thus recommended for use in rehabilitation processes.
Estimating chlorophyll content of spartina alterniflora at leaf level using hyper-spectral data
NASA Astrophysics Data System (ADS)
Wang, Jiapeng; Shi, Runhe; Liu, Pudong; Zhang, Chao; Chen, Maosi
2017-09-01
Spartina alterniflora, one of most successful invasive species in the world, was firstly introduced to China in 1979 to accelerate sedimentation and land formation via so-called "ecological engineering", and it is now widely distributed in coastal saltmarshes in China. A key question is how to retrieve chlorophyll content to reflect growth status, which has important implication of potential invasiveness. In this work, an estimation model of chlorophyll content of S. alterniflora was developed based on hyper-spectral data in the Dongtan Wetland, Yangtze Estuary, China. The spectral reflectance of S. alterniflora leaves and their corresponding chlorophyll contents were measured, and then the correlation analysis and regression (i.e., linear, logarithmic, quadratic, power and exponential regression) method were established. The spectral reflectance was transformed and the feature parameters (i.e., "san bian", "lv feng" and "hong gu") were extracted to retrieve the chlorophyll content of S. alterniflora . The results showed that these parameters had a large correlation coefficient with chlorophyll content. On the basis of the correlation coefficient, mathematical models were established, and the models of power and exponential based on SDb had the least RMSE and larger R2 , which had a good performance regarding the inversion of chlorophyll content of S. alterniflora.
Garcia-Martin, Elena; Pinilla, Isabel; Sancho, Eva; Almarcegui, Carmen; Dolz, Isabel; Rodriguez-Mena, Diego; Fuertes, Isabel; Cuenca, Nicolas
2012-09-01
To evaluate the ability of time-domain and Fourier-domain optical coherence tomographies (OCTs) to detect macular and retinal nerve fiber layer atrophies in retinitis pigmentosa (RP). To test the intrasession reproducibility using three OCT instruments (Stratus, Cirrus, and Spectralis). Eighty eyes of 80 subjects (40 RP patients and 40 healthy subjects) underwent a visual field examination, together with 3 macular scans and 3 optic disk evaluations by the same experienced examiner using 3 OCT instruments. Differences between healthy and RP eyes were compared. The relationship between measurements with each OCT instrument was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation. Macular and retinal nerve fiber layer atrophies were detected in RP patients for all OCT parameters. Macular and retinal nerve fiber layer thicknesses, as determined by the different OCTs, were correlated but significantly different (P < 0.05). Reproducibility was moderately high using Stratus, good using Cirrus and Spectralis, and excellent using the Tru-track technology of Spectralis. In RP eyes, measurements showed higher variability compared with healthy eyes. Differences in thickness measurements existed between OCT instruments, despite there being a high degree of correlation. Fourier-domain OCT can be considered a valid and repeatability technique to detect retinal nerve fiber layer atrophy in RP patients.
Psychometric testing of the modified Care Dependency Scale (Neuro-CDS).
Piredda, Michela; Biagioli, Valentina; Gambale, Giulia; Porcelli, Elisa; Barbaranelli, Claudio; Palese, Alvisa; De Marinis, Maria Grazia
2016-01-01
Effective measures of nursing care dependency in neurorehabilitation are warranted to plan nursing interventions to help patients avoid increasing dependency. The Care Dependency Scale (CDS) is a theory-based, comprehensive tool to evaluate functional disability. This study aimed to modify the CDS for neurological and neurorehabilitation patients (Neuro-CDS) and to test its psychometric properties in adult neurorehabilitation inpatients. Exploratory factor analysis (EFA) was performed using a Maximum Likelihood robust (MLR) estimator. The Barthel Index (BI) was used to evaluate concurrent validity. Stability was measured using the Intra-class Correlation Coefficient (ICC). The sample included 124 patients (mean age = 69.7 years, 54% male). The EFA revealed a two-factor structure with good fit indexes, Factor 1 (Physical care dependence) loaded by 11 items and Factor 2 (Psycho-social care dependence) loaded by 4 items. The correlation between factors was 0.61. Correlations between Factor 1 and the BI and between Factor 2 and the BI were r = 0.843 and r = 0.677, respectively (p < 0.001). The Cronbach's alpha coefficients were 0.99 and 0.88 (Factor 1 and 2). The ICC was 0.98. The Neuro-CDS is multidimensional, valid, reliable, straightforward, and able to measure care dependence in neurorehabilitation patients as a basis for individualized and holistic care.
Foolad, Negar; Ornelas, Jennifer N; Clark, Ashley K; Ali, Ifrah; Sharon, Victoria R; Al Mubarak, Luluah; Lopez, Andrés; Alikhan, Ali; Al Dabagh, Bishr; Firooz, Alireza; Awasthi, Smita; Liu, Yu; Li, Chin-Shang; Sivamani, Raja K
2017-09-01
Cloud-based image sharing technology allows facilitated sharing of images. Cloud-based image sharing technology has not been well-studied for acne assessments or treatment preferences, among international evaluators. We evaluated inter-rater variability of acne grading and treatment recommendations among an international group of dermatologists that assessed photographs. This is a prospective, single visit photographic study to assess inter-rater agreement of acne photographs shared through an integrated mobile device, cloud-based, and HIPAA-compliant platform. Inter-rater agreements for global acne assessment and acne lesion counts were evaluated by the Kendall's coefficient of concordance while correlations between treatment recommendations and acne severity were calculated by Spearman's rank correlation coefficient. There was good agreement for the evaluation of inflammatory lesions (KCC = 0.62, P < 0.0001), noninflammatory lesions (KCC = 0.62, P < 0.0001), and the global acne grading system score (KCC = 0.69, P < 0.0001). Topical retinoid, oral antibiotic, and isotretinoin treatment preferences correlated with photographic based acne severity. Our study supports the use of mobile phone based photography and cloud-based image sharing for acne assessment. Cloud-based sharing may facilitate acne care and research among international collaborators. © 2017 The International Society of Dermatology.
Validation of a Persian version of the Fibromyalgia Impact Questionnaire (FIQ-P).
Bidari, Ali; Hassanzadeh, Morteza; Mohabat, Mohamad-Farzam; Talachian, Elham; Khoei, Effat Merghati
2014-02-01
The aim of this study is to translate, adapt, and validate a Persian version of the Fibromyalgia (FM) Impact Questionnaire (FIQ-P). The FIQ-P was adapted following the translation and back-translation approach; then, it was administered to thirty females with FM. Participants also completed two other validated questionnaires, the Medical Outcome Survey Short Form-36 (SF-36) and the Beck Depression Inventory (BDI). Internal consistency within the FIQ-P items and its test-retest reliability were assessed with Cronbach's alpha and Spearman's correlation coefficient, respectively. Construct validity was analyzed by Spearman's r when correlating the FIQ-P to other questionnaires. The translated version was concordant. Adaptation affected two sub-items of physical function. Participants' mean age ± standard deviation was 40.4 ± 9.0 years. Internal consistency proved good with α = 0.80. Test-retest coefficient ranged from 0.50 for the item "work days missed" to 0.79 for all FIQ-P items. Fair and statistically significant (P < 0.01) correlations were found between the FIQ-P items and two other questionnaires, SF-36 (r = -0.57) and BDI (r = 0.53). We concluded that the FIQ-P is a valid and reliable instrument for measuring health status of Persian-speaking FM patients.
Dupouy, Cécile; Neveux, Jacques; Ouillon, Sylvain; Frouin, Robert; Murakami, Hiroshi; Hochard, Sébastien; Dirberg, Guillaume
2010-01-01
The retrieval of chlorophyll-a concentration from remote sensing reflectance (Rrs) data was tested with the NASA OC4v4 algorithm on the inner New Caledonian lagoon (Case 2) and adjacent open ocean (Case 1) waters. The input to OC4v4 was Rrs measured in situ or modeled from water's inherent optical properties (2001-2007). At open ocean stations, backscattering and absorption coefficients were correlated with chlorophyll (R(2)=0.31-0.51, respectively), in agreement with models for Case 1 waters. Taking spectrofluorometric measurement as reference, the OC4v4 model leads to an average underestimation of 33% of the chlorophyll concentration. For the lagoon waters, OC4v4 performed inadequately because the backscattering coefficient, highly correlated with turbidity and suspended matter (R(2)=0.98), was poorly correlated to chlorophyll (R(2)=0.42). The OC4v4 performance was better in deep lagoon waters for stations with a TDT index (Tchla x depth/turbidity) higher than 19 mg m(-2) NTU(-1) (R(2)=0.974, bias=10.2%). Global Imager Rrs provided a good estimate of Tchla (R(2)=0.79, N=28) in the deeper part of the lagoon. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Monitoring Auroral Electrojet from Polar Cap Stations
NASA Astrophysics Data System (ADS)
Tan, A.; Lyatsky, W.; Lyatskaya, S.
2004-12-01
The auroral electrojet AL and AE geomagnetic activity indices are important for monitoring geomagnetic substorms. In the northern hemisphere these indices are derived from measurements at a set of geomagnetic observatories located in the auroral zone. In the southern hemisphere the major portion of the auroral zone is located on the ocean; this does not allow us to derive the auroral electrojet indices in the same way. We showed that monitoring the auroral electrojet is possible from magnetic field measurements at polar cap stations. For this purpose we used hourly values of geomagnetic field variations at four polar cap stations, distributed along polar cap boundary and occupying a longitudinal sector of about 14 hours, and calculated mean values of the total magnetic field disturbance T = (X2 + Y2 + Z2)1/2 where X, Y, and Z are geomagnetic field components measured at these polar cap stations. The set of the obtained values were called the T index. This index has a clear physical mining: it is the summary of geomagnetic disturbance in all three components averaged over the polar cap boundary. We found that correlation coefficients for the dependence of the T index on both AL and AE indices are as high as ~0.9 and higher. The high correlation of the T index with the AL and AE indices takes place for any UT hour when the stations were located at the night side. The T index further shows good correlation with solar wind parameters: the correlation coefficient for the dependence of the T index on the solar wind-geomagnetic activity coupling function is ~0.8 and higher, which is close to the correlation coefficient for AL index. The T index may be especially important in the cases when ground-based measurements in the auroral zone are impossible as in the southern hemisphere.
Kaux, Jean-François; Delvaux, François; Schaus, Jean; Demoulin, Christophe; Locquet, Médéa; Buckinx, Fanny; Beaudart, Charlotte; Dardenne, Nadia; Van Beveren, Julien; Croisier, Jean-Louis; Forthomme, Bénédicte; Bruyère, Olivier
Translation and validation of algo-functional questionnaire. The lateral elbow tendinopathy is a common injury in tennis players and physical workers. The Patient-Rated Tennis Elbow Evaluation (PRTEE) Questionnaire was specifically designed to measure pain and functional limitations in patients with lateral epicondylitis (tennis elbow). First developed in English, this questionnaire has since been translated into several languages. The aims of the study were to translate and cross-culturally adapt the PRTEE questionnaire into French and to evaluate the reliability and validity of this translated version of the questionnaire (PRTEE-F). The PRTEE was translated and cross-culturally adapted into French according to international guidelines. To assess the reliability and validity of the PRTEE-F, 115 participants were asked twice to fill in the PRTEE-F, and once the Disabilities of Arm, Shoulder and Hand Questionnaire (DASH) and the Short Form Health Survey (SF-36). Internal consistency (using Cronbach's alpha), test-retest reliability (using intraclass correlation coefficient (ICC), standard error of measurement and minimal detectable change), and convergent and divergent validity (using the Spearman's correlation coefficients respectively with the DASH and with some subscales of the SF-36) were assessed. The PRTEE was translated into French without any problems. PRTEE-F showed a good test-retest reliability for the overall score (ICC 0.86) and for each item (ICC 0.8-0.96) and a high internal consistency (Cronbach's alpha = 0.98). The correlation analyses revealed high correlation coefficients between PRTEE-F and DASH (convergent validity) and, as expected, a low or moderate correlation with the divergent subscales of the SF-36 (discriminant validity). There was no floor or ceiling effect. The PRTEE questionnaire was successfully cross-culturally adapted into French. The PRTEE-F is reliable and valid for evaluating French-speaking patients with lateral elbow tendinopathy. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas
2017-07-01
Diffusion-weighted imaging (DWI) is a magnetic resonance imaging (MRI) technique based on measure of water diffusion that can provide information about tissue microstructure, especially about cell count. Increase of cell density induces restriction of water diffusion and decreases apparent diffusion coefficient (ADC). ADC can be divided into three sub-parameters: ADC minimum or ADC min , mean ADC or ADC mean and ADC maximum or ADC max Some studies have suggested that ADC min shows stronger correlations with cell count in comparison to other ADC fractions and may be used as a parameter for estimation of tumor cellularity. The aim of the present meta-analysis was to summarize correlation coefficients between ADC min and cellularity in different tumors based on large patient data. For this analysis, MEDLINE database was screened for associations between ADC and cell count in different tumors up to September 2016. For this work, only data regarding ADC min were included. Overall, 12 publications with 317 patients were identified. Spearman's correlation coefficient was used to analyze associations between ADC min and cellularity. The reported Pearson correlation coefficients in some publications were converted into Spearman correlation coefficients. The pooled correlation coefficient for all included studies was ρ=-0.59 (95% confidence interval (CI)=-0.72 to -0.45), heterogeneity Tau 2 =0.04 (p<0.0001), I 2 =73%, test for overall effect Z=8.67 (p<0.00001). ADC min correlated moderately with tumor cellularity. The calculated correlation coefficient is not stronger in comparison to the reported coefficient for ADC mean and, therefore, ADC min does not represent a better means to reflect cellularity. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P
2016-04-01
Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Callegaro, Chiara; Malkinson, Dan; Ursino, Nadia; Wittenberg, Lea
2016-04-01
The properties of vegetation cover are recognized to be a key factor in determining runoff processes and yield over natural areas. Still, how the actual vegetation spatial distribution affects these processes is not completely understood. In Mediterranean semi-arid regions, patched landscapes are often found, with clumped vegetation, grass or shrubs, surrounded by bare soil patches. These two phases produce a sink-source system for runoff, as precipitation falling over bare areas barely infiltrates and rather flows downslope. In contrast, vegetated patches have high infiltrability and can partially retain the runon water. We hypothesize that, at a relatively small scale, the shape and orientation of bare soil patches with respect to the runoff flow direction is a significant for the connectivity of the runoff flow paths, and consequently for runoff values. We derive an index, FlowShape, which is candidate to be a good proxy for runoff connectivity and thus runoff production in patched environments. FlowShape is an area-weighted average of the geometrical properties of each bare soil patch. Eight experimental plots in northern Israel were monitored during 2 years after a wildfire which occurred in 2006. Runoff was collected and measured - along with rainfall depth - after each rainfall event, at different levels of vegetation cover corresponding to post-fire recovery of vegetation and seasonality. We obtained a good correlation between FlowShape and the runoff coefficient, at two conditions: a minimal percentage of vegetation cover over the plot, and minimal rainfall depth. Our results support the hypothesis that the spatial distribution of the two phases (vegetation and bare soil) in patched landscapes dictates, at least partially, runoff yield. The correlation between the runoff coefficient and FlowShape, which accounts for shape and orientation of soil patches, is higher than the correlation between the runoff coefficient and the bare soil percentage alone. Besides that, the existence of a vegetation cover threshold under which FlowShape loses correlation with runoff yield, suggests that different processes occur at different levels of vegetation cover. On bare or almost bare plots, runoff flows as a sheet, and small isolated plants do not impose a directionality to the flow or interrupt runoff connectivity. On the other hand, rainfall depth - and possibly rainfall intensity - also affect the hydrological processes of infiltration and runoff production, and thus the applicability of any purely geometrical index. We compared the correlation to runoff coefficient with the FlowShape and FlowLength, a well-known index for runoff connectivity (Mayor et al., 2008) which is defined as the average of runoff flow paths over the plot. As microtopography was not available, our plots were idealized as planar hillslopes. We found that FlowShape is a better predictor than FlowLength for runoff yield over our experimental plots.
Someswara Rao, Chinta; Viswanadha Raju, S.
2016-01-01
In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc. PMID:26981409
Someswara Rao, Chinta; Viswanadha Raju, S
2016-03-01
In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc.
Hydrodynamics, mass transfer, and yeast culture performance of a column bioreactor with ejector.
Prokop, A; Janík, P; Sobotka, M; Krumphanzl, V
1983-04-01
A bubble column fitted with an ejector has been tested for its physical and biological performance. The axial diffusion coefficient of the liquid phase in the presence of electrolytes and ethanol was measured by a stimulus-response technique with subsequent evaluation by means of a diffusion model. In contrast to ordinary bubble columns, the coefficient of axial mixing is inversely dependent on the superficial air velocity. The liquid velocity acts in an opposite direction to the backmixing flow in the column. The measurement of volumetric oxygen transfer coefficient in the presence of electrolytes and ethanol was performed using a dynamic gassing-in method adapted for a column. The data were correlated with the superficial air and liquid velocities, total power input, and power for aeration and mixing; the economy coefficient of oxygen transfer was used for finding an optimum ratio of power for aeration and pumping. Growth experiments with Candida utilis on ethanol confirmed some of the above results. Biomass productivity of 2.5 g L(-1) h(-1) testifies about a good transfer capability of the column. Columns fitted with pneumatic and/or hydraulic energy input may be promising for aerobic fermentations considering their mass transfer and mixing characteristics.
Giant flexoelectricity in Ba0.6Sr0.4TiO3/Ni0.8Zn0.2Fe2O4 composite
NASA Astrophysics Data System (ADS)
Li, Yong; Shu, Longlong; Huang, Wenbin; Jiang, Xiaoning; Wang, Hong
2014-10-01
Enhanced flexoelectricity in perovskite ceramics and single crystals has been reported before. In this letter, 3-3 ceramic-ceramic Ba0.6Sr0.4TiO3/Ni0.8Zn0.2Fe2O4 composite with a colossal permittivity was employed in the conventional pure bending experiment in order to examine the transverse flexoelectric response. The measured flexoelectric coefficient at 30 Hz is 128 μC/m and varies to 16 μC/m with the frequency increasing from 30 Hz to 120 Hz, mainly due to the inverse correlation between the permittivity and the frequency. This result reveals the permittivity dependence of flexoelectric coefficient in the frequency dispersion materials, suggesting that the giant permittivity composites can be good flexoelectric materials.
Reliability Estimation of Aero-engine Based on Mixed Weibull Distribution Model
NASA Astrophysics Data System (ADS)
Yuan, Zhongda; Deng, Junxiang; Wang, Dawei
2018-02-01
Aero-engine is a complex mechanical electronic system, based on analysis of reliability of mechanical electronic system, Weibull distribution model has an irreplaceable role. Till now, only two-parameter Weibull distribution model and three-parameter Weibull distribution are widely used. Due to diversity of engine failure modes, there is a big error with single Weibull distribution model. By contrast, a variety of engine failure modes can be taken into account with mixed Weibull distribution model, so it is a good statistical analysis model. Except the concept of dynamic weight coefficient, in order to make reliability estimation result more accurately, three-parameter correlation coefficient optimization method is applied to enhance Weibull distribution model, thus precision of mixed distribution reliability model is improved greatly. All of these are advantageous to popularize Weibull distribution model in engineering applications.
Blind source separation of ex-vivo aorta tissue multispectral images
Galeano, July; Perez, Sandra; Montoya, Yonatan; Botina, Deivid; Garzón, Johnson
2015-01-01
Blind Source Separation methods (BSS) aim for the decomposition of a given signal in its main components or source signals. Those techniques have been widely used in the literature for the analysis of biomedical images, in order to extract the main components of an organ or tissue under study. The analysis of skin images for the extraction of melanin and hemoglobin is an example of the use of BSS. This paper presents a proof of concept of the use of source separation of ex-vivo aorta tissue multispectral Images. The images are acquired with an interference filter-based imaging system. The images are processed by means of two algorithms: Independent Components analysis and Non-negative Matrix Factorization. In both cases, it is possible to obtain maps that quantify the concentration of the main chromophores present in aortic tissue. Also, the algorithms allow for spectral absorbance of the main tissue components. Those spectral signatures were compared against the theoretical ones by using correlation coefficients. Those coefficients report values close to 0.9, which is a good estimator of the method’s performance. Also, correlation coefficients lead to the identification of the concentration maps according to the evaluated chromophore. The results suggest that Multi/hyper-spectral systems together with image processing techniques is a potential tool for the analysis of cardiovascular tissue. PMID:26137366
Sun, Lili; Zhou, Liping; Yu, Yu; Lan, Yukun; Li, Zhiliang
2007-01-01
Polychlorinated diphenyl ethers (PCDEs) have received more and more concerns as a group of ubiquitous potential persistent organic pollutants (POPs). By using molecular electronegativity distance vector (MEDV-4), multiple linear regression (MLR) models are developed for sub-cooled liquid vapor pressures (P(L)), n-octanol/water partition coefficients (K(OW)) and sub-cooled liquid water solubilities (S(W,L)) of 209 PCDEs and diphenyl ether. The correlation coefficients (R) and the leave-one-out cross-validation (LOO) correlation coefficients (R(CV)) of all the 6-descriptor models for logP(L), logK(OW) and logS(W,L) are more than 0.98. By using stepwise multiple regression (SMR), the descriptors are selected and the resulting models are 5-descriptor model for logP(L), 4-descriptor model for logK(OW), and 6-descriptor model for logS(W,L), respectively. All these models exhibit excellent estimate capabilities for internal sample set and good predictive capabilities for external samples set. The consistency between observed and estimated/predicted values for logP(L) is the best (R=0.996, R(CV)=0.996), followed by logK(OW) (R=0.992, R(CV)=0.992) and logS(W,L) (R=0.983, R(CV)=0.980). By using MEDV-4 descriptors, the QSPR models can be used for prediction and the model predictions can hence extend the current database of experimental values.
van der Palen, Roel L F; Roest, Arno A W; van den Boogaard, Pieter J; de Roos, Albert; Blom, Nico A; Westenberg, Jos J M
2018-05-26
The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.
Selvam, Chelliah; Thilagavathi, Ramasamy; Narasimhan, Balasubramanian; Kumar, Pradeep; Jordan, Brian C; Ranganna, Kasturi
2016-02-15
The metabotropic glutamate receptors (mGlu receptors) have emerged as attractive targets for number of neurological and psychiatric disorders. Recently, mGluR5 negative allosteric modulators (NAMs) have gained considerable attention in pharmacological research. Comparative molecular field analysis (CoMFA) was performed on 73 analogs of aryl ether which were reported as mGluR5 NAMs. The study produced a statistically significant model with high correlation coefficient and good predictive abilities. Published by Elsevier Ltd.
Novel Image Encryption Scheme Based on Chebyshev Polynomial and Duffing Map
2014-01-01
We present a novel image encryption algorithm using Chebyshev polynomial based on permutation and substitution and Duffing map based on substitution. Comprehensive security analysis has been performed on the designed scheme using key space analysis, visual testing, histogram analysis, information entropy calculation, correlation coefficient analysis, differential analysis, key sensitivity test, and speed test. The study demonstrates that the proposed image encryption algorithm shows advantages of more than 10113 key space and desirable level of security based on the good statistical results and theoretical arguments. PMID:25143970
Correlation coefficient measurement of the mode-locked laser tones using four-wave mixing.
Anthur, Aravind P; Panapakkam, Vivek; Vujicic, Vidak; Merghem, Kamel; Lelarge, Francois; Ramdane, Abderrahim; Barry, Liam P
2016-06-01
We use four-wave mixing to measure the correlation coefficient of comb tones in a quantum-dash mode-locked laser under passive and active locked regimes. We study the uncertainty in the measurement of the correlation coefficient of the proposed method.
Puntillo, Kathleen A; Neuhaus, John; Arai, Shoshana; Paul, Steven M; Gropper, Michael A; Cohen, Neal H; Miaskowski, Christine
2012-10-01
Determine levels of agreement among intensive care unit patients and their family members, nurses, and physicians (proxies) regarding patients' symptoms and compare levels of mean intensity (i.e., the magnitude of a symptom sensation) and distress (i.e., the degree of emotionality that a symptom engenders) of symptoms among patients and proxy reporters. Prospective study of proxy reporters of symptoms in seriously ill patients. Two intensive care units in a tertiary medical center in the Western United States. Two hundred and forty-five intensive care unit patients, 243 family members, 103 nurses, and 92 physicians. None. On the basis of the magnitude of intraclass correlation coefficients, where coefficients from .35 to .78 are considered to be appropriately robust, correlation coefficients between patients' and family members' ratings met this criterion (≥.35) for intensity in six of ten symptoms. No intensity ratings between patients and nurses had intraclass correlation coefficients >.32. Three symptoms had intensity correlation coefficients of ≥.36 between patients' and physicians' ratings. Correlation coefficients between patients and family members were >.40 for five symptom-distress ratings. No symptoms had distress correlation coefficients of ≥.28 between patients' and nurses' ratings. Two symptoms had symptom-distress correlation coefficients between patients' and physicians' ratings at >.39. Family members, nurses, and physicians reported higher symptom-intensity scores than patients did for 80%, 60%, and 60% of the symptoms, respectively. Family members, nurses, and physicians reported higher symptom-distress scores than patients did for 90%, 70%, and 80% of the symptoms, respectively. Patient-family intraclass correlation coefficients were sufficiently close for us to consider using family members to help assess intensive care unit patients' symptoms. Relatively low intraclass correlation coefficients between intensive care unit clinicians' and patients' symptom ratings indicate that some proxy raters overestimate whereas others underestimate patients' symptoms. Proxy overestimation of patients' symptom scores warrants further study because this may influence decisions about treating patients' symptoms.
Shkilnyy, Andriy; Proulx, Pierre; Sharp, Jamie; Lepage, Martin; Vermette, Patrick
2012-05-01
Scaffolds with adequate mass transport properties are needed in many tissue engineering applications. Fibrin is considered a good biological material to fabricate such scaffolds. However, very little is known about mass transport in fibrin. Therefore, a method based on the analysis of fluorescence intensity for measuring the apparent diffusion coefficient of rhodamine B and fluorescein-labelled bovine serum albumin (FITC-BSA) is described. The experiments are performed in fibrin gels with and without human umbilical vein endothelial cells (HUVEC). The apparent diffusion coefficients of rhodamine B and FITC-BSA in fibrin (fibrinogen concentration of 4 mg/mL) with different cell densities are reported. A LIVE/DEAD(®) assay is performed to confirm the viability of HUVEC seeded at high densities. Diffusion coefficients for rhodamine B remain more or less constant up to 5×10(5) cells/mL and correlate well with literature values measured by other methods in water systems. This indicates that the presence of HUVEC in the fibrin gels (up to 5×10(5) cells/mL) has almost no effect on the diffusion coefficients. Higher cell densities (>5×10(5) cells/mL) result in a decrease of the diffusion coefficients. Diffusion coefficients of rhodamine B and FITC-BSA obtained by this method agree with diffusion coefficients in water predicted by the Stokes-Einstein equation. The experimental design used in this study can be applied to measure diffusion coefficients in different types of gels seeded or not with living cells. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Y. Y.; Shao, Q. X.; Ye, A. Z.; Xing, H. T.
2014-08-01
Integrated water system modeling is a reasonable approach to provide scientific understanding and possible solutions to tackle the severe water crisis faced over the world and to promote the implementation of integrated river basin management. Such a modeling practice becomes more feasible nowadays due to better computing facilities and available data sources. In this study, the process-oriented water system model (HEXM) is developed by integrating multiple water related processes including hydrology, biogeochemistry, environment and ecology, as well as the interference of human activities. The model was tested in the Shaying River Catchment, the largest, highly regulated and heavily polluted tributary of Huai River Basin in China. The results show that: HEXM is well integrated with good performance on the key water related components in the complex catchments. The simulated daily runoff series at all the regulated and less-regulated stations matches observations, especially for the high and low flow events. The average values of correlation coefficient and coefficient of efficiency are 0.81 and 0.63, respectively. The dynamics of observed daily ammonia-nitrogen (NH4N) concentration, as an important index to assess water environmental quality in China, are well captured with average correlation coefficient of 0.66. Furthermore, the spatial patterns of nonpoint source pollutant load and grain yield are also simulated properly, and the outputs have good agreements with the statistics at city scale. Our model shows clear superior performance in both calibration and validation in comparison with the widely used SWAT model. This model is expected to give a strong reference for water system modeling in complex basins, and provide the scientific foundation for the implementation of integrated river basin management all over the world as well as the technical guide for the reasonable regulation of dams and sluices and environmental improvement in river basins.
Shou, Juan; Ren, Limin; Wang, Haitang; Yan, Fei; Cao, Xiaoyun; Wang, Hui; Wang, Zhiliang; Zhu, Shanzhu; Liu, Yao
2016-04-01
The 12-item Short-Form Health Survey (SF-12) is the abridged practical version of SF-36. This cross-sectional study was aimed to assess the reliability and validity of SF-12 for the health status of Chinese community elderly population. The Chinese community elderly people in Xujiahui district of Shanghai were investigated. The internal consistency reliability was assessed using Cronbach's alpha and split-half reliability coefficients. Construct validity was analyzed using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). Spearman's correlation coefficient (ρ) was used for the evaluation of criterion, convergent, and discriminant validity with Spearman's ρ ≥ 0.4 as satisfactory. Comparisons of the SF-12 summary scores among populations that differed in demographics were performed for discriminant validity. Total 1343 individuals aged ≥60 and <85 years old (response rate: 91.3 %) were analyzed. The Cronbach's α value (0.910) and the split-half reliability coefficient (0.812) reflected satisfactory internal consistency reliability of SF-12. EFA extracted a two-factor model (physical and mental health). About 60.7 % of the total variance was explained by the two factors. CFA showed that the two-factor solution provided a good fit to the data. Good convergent validity and discriminant validity of SF-12 were proved by the correction analyses (Spearman's ρ > 0.4) and the comparisons of the SF-12 summary scores among populations (P < 0.05). SF-12 summary scores were significantly correlated with the SF-36 summary scores (Spearman's ρ > 0.4, P < 0.05). In conclusion, SF-12 had satisfactory reliability and validity in measuring health status of Chinese community elderly population in Xujiahui district of Shanghai.
Empirical correlations for axial dispersion coefficient and Peclet number in fixed-bed columns.
Rastegar, Seyed Omid; Gu, Tingyue
2017-03-24
In this work, a new correlation for the axial dispersion coefficient was obtained using experimental data in the literature for axial dispersion in fixed-bed columns packed with particles. The Chung and Wen correlation, the De Ligny correlation are two popular empirical correlations. However, the former lacks the molecular diffusion term and the latter does not consider bed voidage. The new axial dispersion coefficient correlation in this work was based on additional experimental data in the literature by considering both molecular diffusion and bed voidage. It is more comprehensive and accurate. The Peclet number correlation from the new axial dispersion coefficient correlation on the average leads to 12% lower Peclet number values compared to the values from the Chung and Wen correlation, and in many cases much smaller than those from the De Ligny correlation. Copyright © 2017 Elsevier B.V. All rights reserved.
Nerve ultrasound reliability of upper limbs: Effects of examiner training.
Garcia-Santibanez, Rocio; Dietz, Alexander R; Bucelli, Robert C; Zaidman, Craig M
2018-02-01
Duration of training to reliably measure nerve cross-sectional area with ultrasound is unknown. A retrospective review was performed of ultrasound data, acquired and recorded by 2 examiners-an expert and either a trainee with 2 months (novice) or a trainee with 12 months (experienced) of experience. Data on median, ulnar, and radial nerves were reviewed for 42 patients. Interrater reliability was good and varied most with nerve site but little with experience. Coefficient of variation (CoV) range was 9.33%-22.5%. Intraclass correlation coefficient (ICC) was good to excellent (0.65-95) except ulnar nerve-wrist/forearm and radial nerve-humerus (ICC = 0.39-0.59). Interrater differences did not vary with nerve size or body mass index. Expert-novice and expert-experienced interrater differences and CoV were similar. The ulnar nerve-wrist expert-novice interrater difference decreased with time (r s = -0.68, P = 0.001). A trainee with at least 2 months of experience can reliably measure upper limb nerves. Reliability varies by nerve and location and slightly improves with time. Muscle Nerve 57: 189-192, 2018. © 2017 Wiley Periodicals, Inc.
Costa-Tutusaus, Lluís; Guerra-Balic, Myriam
2016-01-28
Lifestyle is intimately related to health. A questionnaire that specifically scores the healthiness of lifestyle of Catalan adolescents is needed. The objective of this study was to develop and validate a scoring questionnaire called VISA-TEEN to assess the healthy lifestyle of young Catalans that can be answered quickly and user-friendly. A lifestyle questionnaire was developed based on the analysis of contributions from two focus groups, one with adolescents and the other with people who work with them (teachers and doctors). A panel of experts validated the content of items that were ultimately selected for the VISA-TEEN questionnaire. Three hundred ninety-six adolescents (215 boys and 181 girls, age = 13-19 years) completed the VISA-TEEN. Internal consistency was assessed using Cronbach's alpha (α) reliability coefficient. Test-retest reliability, using an intraclass correlation coefficient (ICC), was calculated based on scores attained two weeks apart. Construct validity was assessed by the extraction of components with an exploratory factor analysis. The relationship between the scores was measured using the health-related quality of life (HRQoL) KIDSCREEN-10 Index (the relationship was assessed by calculating Pearson's r correlation coefficient). The association of scores in the VISA-TEEN for self-rated health (SRH) was also examined by executing an analysis of variance (ANOVA) between the different categories of this variable. We also calculated the index of fit for factor scales (IFFS) for each component, as well as the discriminatory power of the instrument using Ferguson's δ (delta) coefficient. The VISA-TEEN questionnaire showed acceptable reliability (α = 0.66, αest = 0.77) and a very good test-retest agreement (ICC = 0.860). It could be broken down into the following five components, all with an acceptable or very good IFFS (0.7-0.96): diet, substance abuse, physical activity, Rational Use of Technological Leisure (RUTL), and hygiene. Scores on the VISA-TEEN showed significant correlation with the KIDSCREEN index (r = 0.21, p < 0.001) and were associated with SRH (p < 0.001). The discriminatory power was found to be δ = 0.97. The VISA-TEEN questionnaire developed to study the lifestyle of Catalan adolescents is a valid instrument to apply in this population as it is shown in the present psychometric tests to understand the role of lifestyle in the health of teenagers or to test the efficacy of health campaigns intended to improve teenagers' lifestyle.
Miniature FBG-based fluidic flowmeter to measure hot oil and water
NASA Astrophysics Data System (ADS)
Liu, Zhengyong; Htein, Lin; Cheng, Lun-Kai; Martina, Quincy; Jansen, Rob; Tam, Hwa-Yaw
2017-04-01
In this paper, we present a miniature fluidic flowmeter based on a packaged FBG and laser-heated fibers. The flow rates of water and hydraulic oil were measured by utilizing the proposed flowmeter. The measured results exhibited good sensitivity of 0.339 nm/(m/s) for water and 0.578 nm/(m/s) for oil flow. Experimental results showed that the sensitivity of the fluidic flow sensor is depending on the heat capacity of the fluids, where the fluid with higher heat capacity has higher sensitivity and lower detection limit at the same measurement condition. The real-time flow rates measured by the proposed sensor and a commercial flowmeter installed in the test rig were also compared, demonstrating good agreement with correlation coefficient of 0.9974.
Testing the Difference of Correlated Agreement Coefficients for Statistical Significance
ERIC Educational Resources Information Center
Gwet, Kilem L.
2016-01-01
This article addresses the problem of testing the difference between two correlated agreement coefficients for statistical significance. A number of authors have proposed methods for testing the difference between two correlated kappa coefficients, which require either the use of resampling methods or the use of advanced statistical modeling…
Pig and guinea pig skin as surrogates for human in vitro penetration studies: a quantitative review.
Barbero, Ana M; Frasch, H Frederick
2009-02-01
Both human and animal skin in vitro models are used to predict percutaneous penetration in humans. The objective of this review is a quantitative comparison of permeability and lag time measurements between human and animal skin, including an evaluation of the intra and inter species variability. We limit our focus to domestic pig and rodent guinea pig skin as surrogates for human skin, and consider only studies in which both animal and human penetration of a given chemical were measured jointly in the same lab. When the in vitro permeability of pig and human skin were compared, the Pearson product moment correlation coefficient (r) was 0.88 (P<0.0001), with an intra species average coefficient of variation of skin permeability of 21% for pig and 35% for human, and an inter species average coefficient of variation of 37% for the set of studied compounds (n=41). The lag times of pig skin and human skin did not correlate (r=0.35, P=0.26). When the in vitro permeability of guinea pig and human skin were compared, r=0.96 (P<0.0001), with an average intra species coefficient of variation of 19% for guinea pig and 24% for human, and an inter species coefficient of variation of permeability of 41% for the set of studied compounds (n=15). Lag times of guinea pig and human skin correlated (r=0.90, P<0.0001, n=12). When permeability data was not reported a factor of difference (FOD) of animal to human skin was calculated for pig skin (n=50) and guinea pig skin (n=25). For pig skin, 80% of measurements fell within the range 0.3
Development and testing of the Test of Functional Health Literacy in Dentistry (TOFHLiD).
Gong, Debra A; Lee, Jessica Y; Rozier, R Gary; Pahel, Bhavna T; Richman, Julia A; Vann, William F
2007-01-01
This study aims to evaluate the reliability and validity of the Test of Functional Health Literacy in Dentistry (TOFHLiD), a new instrument to measure functional oral health literacy. TOFHLiD uses text passages and prompts related to fluoride use and access to care to assess reading comprehension and numerical ability. Parents of pediatric dental patients (n = 102) were administered TOFHLiD, a medical literacy comprehension test (TOFHLA), and two word recognition tests [Rapid Estimate of Adult Literacy in Dentistry (REALD), Rapid Estimate of Adult Literacy in Medicine (REALM)]. This design provided assessments of dental and medical health literacy by all subjects, both measured with two different methods (reading/numeracy ability and word recognition). Construct validity of TOFHLiD was assessed by entering the correlation coefficients for all pairwise comparisons of literacy instruments into a multitrait-multimethod matrix. Internal reliability of TOFHLiD was assessed with Cronbach's alpha. Criterion-related predictive validity was tested by associations between the TOFHLiD scores and the three measures of oral health in multivariate regression analyses. The correlation coefficient for TOFHLiD and REALD-99 scores (monotrait-heteromethod) was high (r = 0.82, P < 0.05). Coefficients between TOFHLiD and TOFHLA (heterotrait-monomethod: r = 0.52) and REALM (heterotrait-heteromethod: r = 0.53) were smaller than coefficients for convergent validity Cronbach's alpha for TOFHLiD was 0.63. TOFHLiD was positively correlated with OHIP-14 (P < 0.05), but not with parent or child oral health. TOFHLA was not related to dental outcomes. TOFHLiD demonstrates good convergent validity but only moderate ability to discriminate between dental and medical health literacy. Its predictive validity is only partially established, and internal consistency just meets the threshold for acceptability. Results provide solid support for more research, but not widespread use in clinical or public health practice.
Subcortical structure segmentation using probabilistic atlas priors
NASA Astrophysics Data System (ADS)
Gouttard, Sylvain; Styner, Martin; Joshi, Sarang; Smith, Rachel G.; Cody Hazlett, Heather; Gerig, Guido
2007-03-01
The segmentation of the subcortical structures of the brain is required for many forms of quantitative neuroanatomic analysis. The volumetric and shape parameters of structures such as lateral ventricles, putamen, caudate, hippocampus, pallidus and amygdala are employed to characterize a disease or its evolution. This paper presents a fully automatic segmentation of these structures via a non-rigid registration of a probabilistic atlas prior and alongside a comprehensive validation. Our approach is based on an unbiased diffeomorphic atlas with probabilistic spatial priors built from a training set of MR images with corresponding manual segmentations. The atlas building computes an average image along with transformation fields mapping each training case to the average image. These transformation fields are applied to the manually segmented structures of each case in order to obtain a probabilistic map on the atlas. When applying the atlas for automatic structural segmentation, an MR image is first intensity inhomogeneity corrected, skull stripped and intensity calibrated to the atlas. Then the atlas image is registered to the image using an affine followed by a deformable registration matching the gray level intensity. Finally, the registration transformation is applied to the probabilistic maps of each structures, which are then thresholded at 0.5 probability. Using manual segmentations for comparison, measures of volumetric differences show high correlation with our results. Furthermore, the dice coefficient, which quantifies the volumetric overlap, is higher than 62% for all structures and is close to 80% for basal ganglia. The intraclass correlation coefficient computed on these same datasets shows a good inter-method correlation of the volumetric measurements. Using a dataset of a single patient scanned 10 times on 5 different scanners, reliability is shown with a coefficient of variance of less than 2 percents over the whole dataset. Overall, these validation and reliability studies show that our method accurately and reliably segments almost all structures. Only the hippocampus and amygdala segmentations exhibit relative low correlation with the manual segmentation in at least one of the validation studies, whereas they still show appropriate dice overlap coefficients.
Estimating Seven Coefficients of Pairwise Relatedness Using Population-Genomic Data
Ackerman, Matthew S.; Johri, Parul; Spitze, Ken; Xu, Sen; Doak, Thomas G.; Young, Kimberly; Lynch, Michael
2017-01-01
Population structure can be described by genotypic-correlation coefficients between groups of individuals, the most basic of which are the pairwise relatedness coefficients between any two individuals. There are nine pairwise relatedness coefficients in the most general model, and we show that these can be reduced to seven coefficients for biallelic loci. Although all nine coefficients can be estimated from pedigrees, six coefficients have been beyond empirical reach. We provide a numerical optimization procedure that estimates all seven reduced coefficients from population-genomic data. Simulations show that the procedure is nearly unbiased, even at 3× coverage, and errors in five of the seven coefficients are statistically uncorrelated. The remaining two coefficients have a negative correlation of errors, but their sum provides an unbiased assessment of the overall correlation of heterozygosity between two individuals. Application of these new methods to four populations of the freshwater crustacean Daphnia pulex reveal the occurrence of half siblings in our samples, as well as a number of identical individuals that are likely obligately asexual clone mates. Statistically significant negative estimates of these pairwise relatedness coefficients, including inbreeding coefficients that were typically negative, underscore the difficulties that arise when interpreting genotypic correlations as estimations of the probability that alleles are identical by descent. PMID:28341647
Ignjatović Ristić, Dragana; Cohen, Dan; Obradović, Andrea; Nikić-Đuričić, Katarina; Drašković, Marija; Hinić, Darko
2018-02-01
The inconsistency in clinician and patient ratings of clozapine-induced side effects underscore the need to supplement clinician-based estimates of side effects with patient-reported ones. The main aims of the study are validation of the Glasgow antipsychotic side-effects scale for clozapine (GASS-C) in Serbian inpatients/outpatients with schizophrenia or schizo-affective disorder and recommendations for its future use, based on common and rare clozapine-associated side-effects. The GASS-C was administered to 95 outpatients/inpatients diagnosed with schizophrenia, schizoaffective, or chronic psychotic disorder. The scale showed good overall reliability, with an internal consistency coefficient of α = 0.84, an average retest coefficient of rho = 0.76, and a Spearman-Brown coefficient of validity of 0.81. Side effects were absent or mild in 64.2% of the patients, moderate in 31.6%, severe in 4.2%; 14% of the subjects considered their symptoms distressing. The most commonly reported side-effects were drowsiness, thirst, frequent urination, and dry mouth. Women reported more side effects than men, and patients not in a relationship reported significantly fewer side effects than patients in a relationship. Results indicate a weak positive correlation (rho = 0.231; p = .025) between severity of side effects and clozapine dose. The GASS-C showed good psychometric characteristics in clinical population of patients on clozapine. In future studies, clozapine serum concentrations should be measured when using the GASS-C to monitor side effects.
Kumar, Dharmendra; Ahmed, Syed Moied; Ali, Shahna; Ray, Utpal; Varshney, Ankur; Doley, Kashmiri
2015-11-01
Central venous pressure (CVP) assesses the volume status of patients. However, this technique is not without complications. We, therefore, measured peripheral venous pressure (PVP) to see whether it can replace CVP. To evaluate the correlation and agreement between CVP and PVP after passive leg raise (PLR) in critically ill patients on mechanical ventilation. Prospective observational study in Intensive Care Unit. Fifty critically ill patients on mechanical ventilation were included in the study. CVP and PVP measurements were taken using a water column manometer. Measurements were taken in the supine position and subsequently after a PLR of 45°. Pearson's correlation and Bland-Altman's analysis. This study showed a fair correlation between CVP and PVP after a PLR of 45° (correlation coefficient, r = 0.479; P = 0.0004) when the CVP was <10 cmH2O. However, the correlation was good when the CVP was >10 cmH2O. Bland-Altman analysis showed 95% limits of agreement to be -2.912-9.472. PVP can replace CVP for guiding fluid therapy in critically ill patients.
Wnuk, Marcin
2017-01-01
This study verifies the psychometric properties of the Santa Clara Strength of Religious Faith Questionnaire (SCSORFQ). This measure consists of 10 items regarding strength of religious faith, regardless of religious denomination or affiliation. Participants were 177 students from Chile and 393 students from Poland. The SCSORFQ method is a reliable measure with good internal consistency evaluated by the α-Cronbach coefficient. Factor analysis statistically confirmed the unidimensional structure of the SCSORFQ. The strength of religious faith in both student groups was moderate to strong correlated with public or private aspects of religiousness and strong correlated with spiritual experiences. It was weakly correlated with the cognitive indicator of well-being as satisfaction with life as well as with existential variables like hope and meaning of life. The results confirm that the SCSORFQ is psychometrically sound and is therefore recommended for use by researchers studying the construct of religiousness.
Kalpathy-Cramer, Jayashree; Campbell, J Peter; Erdogmus, Deniz; Tian, Peng; Kedarisetti, Dharanish; Moleta, Chace; Reynolds, James D; Hutcheson, Kelly; Shapiro, Michael J; Repka, Michael X; Ferrone, Philip; Drenser, Kimberly; Horowitz, Jason; Sonmez, Kemal; Swan, Ryan; Ostmo, Susan; Jonas, Karyn E; Chan, R V Paul; Chiang, Michael F
2016-11-01
To determine expert agreement on relative retinopathy of prematurity (ROP) disease severity and whether computer-based image analysis can model relative disease severity, and to propose consideration of a more continuous severity score for ROP. We developed 2 databases of clinical images of varying disease severity (100 images and 34 images) as part of the Imaging and Informatics in ROP (i-ROP) cohort study and recruited expert physician, nonexpert physician, and nonphysician graders to classify and perform pairwise comparisons on both databases. Six participating expert ROP clinician-scientists, each with a minimum of 10 years of clinical ROP experience and 5 ROP publications, and 5 image graders (3 physicians and 2 nonphysician graders) who analyzed images that were obtained during routine ROP screening in neonatal intensive care units. Images in both databases were ranked by average disease classification (classification ranking), by pairwise comparison using the Elo rating method (comparison ranking), and by correlation with the i-ROP computer-based image analysis system. Interexpert agreement (weighted κ statistic) compared with the correlation coefficient (CC) between experts on pairwise comparisons and correlation between expert rankings and computer-based image analysis modeling. There was variable interexpert agreement on diagnostic classification of disease (plus, preplus, or normal) among the 6 experts (mean weighted κ, 0.27; range, 0.06-0.63), but good correlation between experts on comparison ranking of disease severity (mean CC, 0.84; range, 0.74-0.93) on the set of 34 images. Comparison ranking provided a severity ranking that was in good agreement with ranking obtained by classification ranking (CC, 0.92). Comparison ranking on the larger dataset by both expert and nonexpert graders demonstrated good correlation (mean CC, 0.97; range, 0.95-0.98). The i-ROP system was able to model this continuous severity with good correlation (CC, 0.86). Experts diagnose plus disease on a continuum, with poor absolute agreement on classification but good relative agreement on disease severity. These results suggest that the use of pairwise rankings and a continuous severity score, such as that provided by the i-ROP system, may improve agreement on disease severity in the future. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
First quality score for referral letters in gastroenterology-a validation study.
Eskeland, Sigrun Losada; Brunborg, Cathrine; Seip, Birgitte; Wiencke, Kristine; Hovde, Øistein; Owen, Tanja; Skogestad, Erik; Huppertz-Hauss, Gert; Halvorsen, Fred-Arne; Garborg, Kjetil; Aabakken, Lars; de Lange, Thomas
2016-10-08
To create and validate an objective and reliable score to assess referral quality in gastroenterology. An observational multicentre study. 25 gastroenterologists participated in selecting variables for a Thirty Point Score (TPS) for quality assessment of referrals to gastroenterology specialist healthcare for 9 common indications. From May to September 2014, 7 hospitals from the South-Eastern Norway Regional Health Authority participated in collecting and scoring 327 referrals to a gastroenterologist. Correlation between the TPS and a visual analogue scale (VAS) for referral quality. The 327 referrals had an average TPS of 13.2 (range 1-25) and an average VAS of 4.7 (range 0.2-9.5). The reliability of the score was excellent, with an intra-rater intraclass correlation coefficient (ICC) of 0.87 and inter-rater ICC of 0.91. The overall correlation between the TPS and the VAS was moderate (r=0.42), and ranged from fair to substantial for the various indications. Mean agreement was good (ICC=0.47, 95% CI (0.34 to 0.57)), ranging from poor to good. The TPS is reliable, objective and shows good agreement with the subjective VAS. The score may be a useful tool for assessing referral quality in gastroenterology, particularly important when evaluating the effect of interventions to improve referral quality. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
ERIC Educational Resources Information Center
Wilson, Celia M.
2010-01-01
Research pertaining to the distortion of the squared canonical correlation coefficient has traditionally been limited to the effects of sampling error and associated correction formulas. The purpose of this study was to compare the degree of attenuation of the squared canonical correlation coefficient under varying conditions of score reliability.…
Thin and Slow Smoke Detection by Using Frequency Image
NASA Astrophysics Data System (ADS)
Zheng, Guang; Oe, Shunitiro
In this paper, a new method to detect thin and slow smoke for early fire alarm by using frequency image has been proposed. The correlation coefficient of the frequency image between the current stage and the initial stage are calculated, so are the gray image correlation coefficient of the color image. When the thin smoke close to transparent enters into the camera view, the correlation coefficient of the frequency image becomes small, while the gray image correlation coefficient of the color image hardly change and keep large. When something which is not transparent, like human beings, etc., enters into the camera view, the correlation coefficient of the frequency image becomes small, as well as that of color image. Based on the difference of correlation coefficient between frequency image and color image in different situations, the thin smoke can be detected. Also, considering the movement of the thin smoke, miss detection caused by the illustration change or noise can be avoided. Several experiments in different situations are carried out, and the experimental results show the effect of the proposed method.
Statistical Study of Turbulence: Spectral Functions and Correlation Coefficients
NASA Technical Reports Server (NTRS)
Frenkiel, Francois N.
1958-01-01
In reading the publications on turbulence of different authors, one often runs the risk of confusing the various correlation coefficients and turbulence spectra. We have made a point of defining, by appropriate concepts, the differences which exist between these functions. Besides, we introduce in the symbols a few new characteristics of turbulence. In the first chapter, we study some relations between the correlation coefficients and the different turbulence spectra. Certain relations are given by means of demonstrations which could be called intuitive rather than mathematical. In this way we demonstrate that the correlation coefficients between the simultaneous turbulent velocities at two points are identical, whether studied in Lagrange's or in Euler's systems. We then consider new spectra of turbulence, obtained by study of the simultaneous velocities along a straight line of given direction. We determine some relations between these spectra and the correlation coefficients. Examining the relation between the spectrum of the turbulence measured at a fixed point and the longitudinal-correlation curve given by G. I. Taylor, we find that this equation is exact only when the coefficient is very small.
[Electroencephalogram Feature Selection Based on Correlation Coefficient Analysis].
Zhou, Jinzhi; Tang, Xiaofang
2015-08-01
In order to improve the accuracy of classification with small amount of motor imagery training data on the development of brain-computer interface (BCD systems, we proposed an analyzing method to automatically select the characteristic parameters based on correlation coefficient analysis. Throughout the five sample data of dataset IV a from 2005 BCI Competition, we utilized short-time Fourier transform (STFT) and correlation coefficient calculation to reduce the number of primitive electroencephalogram dimension, then introduced feature extraction based on common spatial pattern (CSP) and classified by linear discriminant analysis (LDA). Simulation results showed that the average rate of classification accuracy could be improved by using correlation coefficient feature selection method than those without using this algorithm. Comparing with support vector machine (SVM) optimization features algorithm, the correlation coefficient analysis can lead better selection parameters to improve the accuracy of classification.
Quantifying the range of cross-correlated fluctuations using a q- L dependent AHXA coefficient
NASA Astrophysics Data System (ADS)
Wang, Fang; Wang, Lin; Chen, Yuming
2018-03-01
Recently, based on analogous height cross-correlation analysis (AHXA), a cross-correlation coefficient ρ×(L) has been proposed to quantify the levels of cross-correlation on different temporal scales for bivariate series. A limitation of this coefficient is that it cannot capture the full information of cross-correlations on amplitude of fluctuations. In fact, it only detects the cross-correlation at a specific order fluctuation, which might neglect some important information inherited from other order fluctuations. To overcome this disadvantage, in this work, based on the scaling of the qth order covariance and time delay L, we define a two-parameter dependent cross-correlation coefficient ρq(L) to detect and quantify the range and level of cross-correlations. This new version of ρq(L) coefficient leads to the formation of a ρq(L) surface, which not only is able to quantify the level of cross-correlations, but also allows us to identify the range of fluctuation amplitudes that are correlated in two given signals. Applications to the classical ARFIMA models and the binomial multifractal series illustrate the feasibility of this new coefficient ρq(L) . In addition, a statistical test is proposed to quantify the existence of cross-correlations between two given series. Applying our method to the real life empirical data from the 1999-2000 California electricity market, we find that the California power crisis in 2000 destroys the cross-correlation between the price and the load series but does not affect the correlation of the load series during and before the crisis.
Adler, Jeremy; Parmryd, Ingela
2010-08-01
The Pearson correlation coefficient (PCC) and the Mander's overlap coefficient (MOC) are used to quantify the degree of colocalization between fluorophores. The MOC was introduced to overcome perceived problems with the PCC. The two coefficients are mathematically similar, differing in the use of either the absolute intensities (MOC) or of the deviation from the mean (PCC). A range of correlated datasets, which extend to the limits of the PCC, only evoked a limited response from the MOC. The PCC is unaffected by changes to the offset while the MOC increases when the offset is positive. Both coefficients are independent of gain. The MOC is a confusing hybrid measurement, that combines correlation with a heavily weighted form of co-occurrence, favors high intensity combinations, downplays combinations in which either or both intensities are low and ignores blank pixels. The PCC only measures correlation. A surprising finding was that the addition of a second uncorrelated population can substantially increase the measured correlation, demonstrating the importance of excluding background pixels. Overall, since the MOC is unresponsive to substantial changes in the data and is hard to interpret, it is neither an alternative to nor a useful substitute for the PCC. The MOC is not suitable for making measurements of colocalization either by correlation or co-occurrence.
Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti
2017-01-01
to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; p<0.05). The questionnaire had also been demonstrated to have a good validity with a proven high correlation to each question of SF-36 (p<0.05). the Indonesian version of GERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.
Dhikav, Vikas; Duraiswamy, Sharmila; Anand, Kuljeet Singh
2017-01-01
Hippocampus undergoes atrophy in patients with Alzheimer's disease (AD). Calculation of hippocampal volumes can be done by a variety of methods using T1-weighted images of magnetic resonance imaging (MRI) of the brain. Medial temporal lobes atrophy (MTL) can be rated visually using T1-weighted MRI brain images. The present study was done to see if any correlation existed between hippocampal volumes and visual rating scores of the MTL using Scheltens Visual Rating Method. We screened 84 subjects presented to the Department of Neurology of a Tertiary Care Hospital and enrolled forty subjects meeting the National Institute of Neurological and Communicative Disorders and Stroke, AD related Disease Association criteria. Selected patients underwent MRI brain and T1-weighted images in a plane perpendicular to long axis of hippocampus were obtained. Hippocampal volumes were calculated manually using a standard protocol. The calculated hippocampal volumes were correlated with Scheltens Visual Rating Method for Rating MTL. A total of 32 cognitively normal age-matched subjects were selected to see the same correlation in the healthy subjects as well. Sensitivity and specificity of both methods was calculated and compared. There was an insignificant correlation between the hippocampal volumes and MTL rating scores in cognitively normal elderly ( n = 32; Pearson Correlation coefficient = 0.16, P > 0.05). In the AD Group, there was a moderately strong correlation between measured hippocampal volumes and MTL Rating (Pearson's correlation coefficient = -0.54; P < 0.05. There was a moderately strong correlation between hippocampal volume and Mini-Mental Status Examination in the AD group. Manual delineation was superior compared to the visual method ( P < 0.05). Good correlation was present between manual hippocampal volume measurements and MTL scores. Sensitivity and specificity of manual measurement of hippocampus was higher compared to visual rating scores for MTL in patients with AD.
Dhikav, Vikas; Duraiswamy, Sharmila; Anand, Kuljeet Singh
2017-01-01
Introduction: Hippocampus undergoes atrophy in patients with Alzheimer's disease (AD). Calculation of hippocampal volumes can be done by a variety of methods using T1-weighted images of magnetic resonance imaging (MRI) of the brain. Medial temporal lobes atrophy (MTL) can be rated visually using T1-weighted MRI brain images. The present study was done to see if any correlation existed between hippocampal volumes and visual rating scores of the MTL using Scheltens Visual Rating Method. Materials and Methods: We screened 84 subjects presented to the Department of Neurology of a Tertiary Care Hospital and enrolled forty subjects meeting the National Institute of Neurological and Communicative Disorders and Stroke, AD related Disease Association criteria. Selected patients underwent MRI brain and T1-weighted images in a plane perpendicular to long axis of hippocampus were obtained. Hippocampal volumes were calculated manually using a standard protocol. The calculated hippocampal volumes were correlated with Scheltens Visual Rating Method for Rating MTL. A total of 32 cognitively normal age-matched subjects were selected to see the same correlation in the healthy subjects as well. Sensitivity and specificity of both methods was calculated and compared. Results: There was an insignificant correlation between the hippocampal volumes and MTL rating scores in cognitively normal elderly (n = 32; Pearson Correlation coefficient = 0.16, P > 0.05). In the AD Group, there was a moderately strong correlation between measured hippocampal volumes and MTL Rating (Pearson's correlation coefficient = −0.54; P < 0.05. There was a moderately strong correlation between hippocampal volume and Mini-Mental Status Examination in the AD group. Manual delineation was superior compared to the visual method (P < 0.05). Conclusions: Good correlation was present between manual hippocampal volume measurements and MTL scores. Sensitivity and specificity of manual measurement of hippocampus was higher compared to visual rating scores for MTL in patients with AD. PMID:28298839
Dong, Yingbo; Lin, Hai; He, Yinhai
2017-03-01
The physicochemical properties of the 24 modified clinoptilolite samples and their ammonia-nitrogen removal rates were measured to investigate the correlation between them. The modified clinoptilolites obtained by acid modification, alkali modification, salt modification, and thermal modification were used to adsorb ammonia-nitrogen. The surface area, average pore width, macropore volume, mecropore volume, micropore volume, cation exchange capacity (CEC), zeta potential, silicon-aluminum ratios, and ammonia-nitrogen removal rate of the 24 modified clinoptilolite samples were measured. Subsequently, the linear regression analysis method was used to research the correlation between the physicochemical property of the different modified clinoptilolite samples and the ammonia-nitrogen removal rate. Results showed that the CEC was the major physicochemical property affecting the ammonia-nitrogen removal performance. According to the impacts from strong to weak, the order was CEC > silicon-aluminum ratios > mesopore volume > micropore volume > surface area. On the contrary, the macropore volume, average pore width, and zeta potential had a negligible effect on the ammonia-nitrogen removal rate. The relational model of physicochemical property and ammonia-nitrogen removal rate of the modified clinoptilolite was established, which was ammonia-nitrogen removal rate = 1.415[CEC] + 173.533 [macropore volume] + 0.683 [surface area] + 4.789[Si/Al] - 201.248. The correlation coefficient of this model was 0.982, which passed the validation of regression equation and regression coefficients. The results of the significance test showed a good fit to the correlation model.
Marics, Gábor; Koncz, Levente; Eitler, Katalin; Vatai, Barbara; Szénási, Boglárka; Zakariás, David; Mikos, Borbála; Körner, Anna; Tóth-Heyn, Péter
2015-03-19
Continuous glucose monitoring (CGM) originally was developed for diabetic patients and it may be a useful tool for monitoring glucose changes in pediatric intensive care unit (PICU). Its use is, however, limited by the lack of sufficient data on its reliability at insufficient peripheral perfusion. We aimed to correlate the accuracy of CGM with laboratory markers relevant to disturbed tissue perfusion. In 38 pediatric patients (age range, 0-18 years) requiring intensive care we tested the effect of pH, lactate, hematocrit and serum potassium on the difference between CGM and meter glucose measurements. Guardian® (Medtronic®) CGM results were compared to GEM 3000 (Instrumentation laboratory®) and point-of-care measurements. The clinical accuracy of CGM was evaluated by Clarke Error Grid -, Bland-Altman analysis and Pearson's correlation. We used Friedman test for statistical analysis (statistical significance was established as a p < 0.05). CGM values exhibited a considerable variability without any correlation with the examined laboratory parameters. Clarke, Bland-Altman analysis and Pearson's correlation coefficient demonstrated a good clinical accuracy of CGM (zone A and B = 96%; the mean difference between reference and CGM glucose was 1,3 mg/dL, 48 from the 780 calibration pairs overrunning the 2 standard deviation; Pearson's correlation coefficient: 0.83). The accuracy of CGM measurements is independent of laboratory parameters relevant to tissue hypoperfusion. CGM may prove a reliable tool for continuous monitoring of glucose changes in PICUs, not much influenced by tissue perfusion, but still not appropriate for being the base for clinical decisions.
NASA Astrophysics Data System (ADS)
Rollmann, P.; Spindler, K.; Müller-Steinhagen, H.
2011-08-01
The heat transfer, pressure drop and flow patterns during flow boiling of R407C in a horizontal microfin tube have been investigated. The microfin tube is made of copper with a total fin number of 55 and a helix angle of 15°. The fin height is 0.24 mm and the inner tube diameter at fin root is 8.95 mm. The test tube is 1 m long. It is heated electrically. The experiments have been performed at saturation temperatures between -30°C and +10°C. The mass flux was varied between 25 and 300 kg/m2/s, the heat flux from 20,000 W/m2 down to 1,000 W/m2. The vapour quality was kept constant at 0.1, 0.3, 0.5, 0.7 at the inlet and 0.8, 1.0 at the outlet, respectively. The measured heat transfer coefficient is compared with the correlations of Cavallini et al., Shah as well as Zhang et al. Cavallini's correlation contains seven experimental constants. After fitting these constants to our measured values, the correlation achieves good agreement. The measured pressure drop is compared to the correlations of Pierre, Kuo and Wang as well as Müller-Steinhagen and Heck. The best agreement is achieved with the correlation of Kuo and Wang. Almost all values are calculated within an accuracy of ±30%. The flow regimes were observed. It is shown, that changes in the flow regime affect the heat transfer coefficient significantly.
Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas
2018-04-01
Our purpose was to provide data regarding relationships between different imaging and histopathological parameters in HNSCC. MEDLINE library was screened for associations between different imaging parameters and histopathological features in HNSCC up to December 2017. Only papers containing correlation coefficients between different imaging parameters and histopathological findings were acquired for the analysis. Associations between 18 F-FDG positron emission tomography (PET) and KI 67 were reported in 8 studies (236 patients). The pooled correlation coefficient was 0.20 (95% CI = [-0.04; 0.44]). Furthermore, in 4 studies (64 patients), associations between 18 F-fluorothymidine PET and KI 67 were analyzed. The pooled correlation coefficient between SUV max and KI 67 was 0.28 (95% CI = [-0.06; 0.94]). In 2 studies (23 patients), relationships between KI 67 and dynamic contrast-enhanced magnetic resonance imaging were reported. The pooled correlation coefficient between K trans and KI 67 was -0.68 (95% CI = [-0.91; -0.44]). Two studies (31 patients) investigated correlation between apparent diffusion coefficient (ADC) and KI 67. The pooled correlation coefficient was -0.61 (95% CI = [-0.84; -0.38]). In 2 studies (117 patients), relationships between 18 F-FDG PET and p53 were analyzed. The pooled correlation coefficient was 0.0 (95% CI = [-0.87; 0.88]). There were 3 studies (48 patients) that investigated associations between ADC and tumor cell count in HNSCC. The pooled correlation coefficient was -0.53 (95% CI = [-0.74; -0.32]). Associations between 18 F-FDG PET and HIF-1α were investigated in 3 studies (72 patients). The pooled correlation coefficient was 0.44 (95% CI = [-0.20; 1.08]). ADC may predict cell count and proliferation activity, and SUV max may predict expression of HIF-1α in HNSCC. SUV max cannot be used as surrogate marker for expression of KI 67 and p53. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Speech perception task with pseudowords.
Appezzato, Mariana Martins; Hackerott, Maria Mercedes Saraiva; Avila, Clara Regina Brandão de
2018-01-01
Purpose Prepare a list of pseudowords in Brazilian Portuguese to assess the auditory discrimination ability of schoolchildren and investigate the internal consistency of test items and the effect of school grade on discrimination performance. Methods Study participants were 60 schoolchildren (60% female) enrolled in the 3rd (n=14), 4th (n=24) and 5th (n=22) grades of an elementary school in the city of Sao Paulo, Brazil, aged between eight years and two months and 11 years and eight months (99 to 136 months; mean=120.05; SD=10.26), with average school performance score of 7.21 (minimum 5.0; maximum 10; SD=1.23). Forty-eight minimal pairs of Brazilian Portuguese pseudowords distinguished by a single phoneme were prepared. The participants' responses (whether the elements of the pairs were the same or different) were noted and analyzed. The data were analyzed using the Cronbach's Alpha Coefficient, Spearman's Correlation Coefficient, and Bonferroni Post-hoc Test at significance level of 0.05. Results Internal consistency analysis indicated the deletion of 20 pairs. The 28 items with results showed good internal consistency (α=0.84). The maximum and minimum scores of correct discrimination responses were 34 and 16, respectively (mean=30.79; SD=3.68). No correlation was observed between age, school performance, and discrimination performance, and no difference between school grades was found. Conclusion Most of the items proposed for assessing the auditory discrimination of speech sounds showed good internal consistency in relation to the task. Age and school grade did not improve the auditory discrimination of speech sounds.
Morita, T; Nakamura, K; Osuga, T; Yokoyama, N; Khoirun, N; Morishita, K; Sasaki, N; Ohta, H; Takiguchi, M
2017-08-01
To assess the repeatability and characteristics of echocardiographic indices of the right ventricular (RV) function derived from speckle-tracking echocardiography. Fourteen laboratory Beagles and 103 privately owned dogs without cardiac disease were involved in this study. Right ventricular longitudinal strain, strain rate, and a strain-related index for assessing RV dyssynchrony derived from speckle-tracking echocardiography were obtained by two different observers using five Beagles. Within-day, between-day, and interobserver coefficients of variation and the intraclass correlation coefficient of speckle-tracking echocardiography indices were determined. Both speckle-tracking echocardiography and conventional indices of RV function, including the peak velocity of systolic tricuspid annular motion, tricuspid annulus plane systolic excursion, fractional area change, and the Tei index, were obtained from 14 Beagles and 103 privately owned dogs. Relationships between echocardiographic indices and the body weight, heart rate, age, and sex were estimated by regression analysis. Speckle-tracking echocardiographic indices showed good within-day repeatability, between-day and interobserver repeatability were moderate to good. In large dogs, RV longitudinal strain, strain rate, and fractional area change were significantly decreased, while the index of RV dyssynchrony, systolic tricuspid annular motion, tricuspid annulus plane systolic excursion, and the Tei index were increased. All speckle-tracking and conventional echocardiographic indices were correlated with the body weight. The speckle-tracking echocardiography indices were highly repeatable and body weight affected speckle-tracking echocardiography indices in dogs. Further studies are needed to apply speckle-tracking echocardiography indices in dogs with cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Knowledge About Chronic Orofacial Pain Among General Dentists of Kermanshah, Iran.
Rezaei, Fatemeh; Sharifi, Roohollah; Shahrezaee, Hamid R; Mozaffari, Hamid R
2017-01-01
Diagnosis and treatment of chronic orofacial pain are one of the most challenging issues in dentistry. The purpose of this study was to assess the knowledge of general dentists regarding orofacial pain in Kermanshah, Iran. This cross-sectional study was conducted in 2016 including general dentists of Kermanshah city. A researcher-designed questionnaire was administered to collect demographic data as well as measuring knowledge of the dentists in four sections including etiology, clinical presentations, physical examination, and treatment of chronic orofacial pain. The questionnaire had acceptable validity (content validity > 0.9) and reliability (intraclass correlation coefficient= 0.857 for test re-test; Cronbach's alpha= 0.72 for internal consistency). The data were analyzed by the SPSS software (ver. 18.0) using Spearman's correlation coefficient ( P < 0.05). There were 121 male (72.9%) and 45 female (27.1%) dentists with mean (SD) age of 40.55 (8.03) years and mean (SD) practice history of 13.28 (8.43) years. Mean (SD) knowledge score was 10.54 (2.36) (maximum possible score= 15). 48.2% of dentists had good knowledge in overall. 48.2% about etiology, 45.2% about clinical presentations, 36.1% about physical examination, and 7.8% about treatment had good knowledge. Knowledge had direct and significant relationship with age (r = 0.179; P = 0.022) and practice history (r = 0.18; P = 0.021). The results showed that the studied dentists did not have enough knowledge about chronic orofacial pain especially in the treatment field. Therefore, it is recommended to implement educational programs to improve their knowledge.
[Topological models of retention index of thin-layer chromatogram for chiral organic acids].
Li, Mingjian; Wang, Yuxiao; Feng, Hui; Feng, Changjun
2014-03-01
On the basis of Kier's molecular connectivity indices and conjugated matrix, novel molecular connectivity indices ((m) G(t)(v)) were defined and calculated for 18 chiral hydroxyl acids and amino acids. The chiral connectivity indices ((m)C(t)(v)) were introduced by extending (m)G(t)(v): (m)C(t)(v) = (m)G(t)(v) x w(j), where w(j) is the chiral index. The quantitative structure-retention index relationship (QSRR) between the retention index (R(M)) of thin-layer chromatogram for the chiral organic acids and (m)C(t)(v) was studied by multivariate statistical regression. By leaps-and-bounds regression analysis, the best four-parameter QSRR model was set up, and the traditional correlation coefficient (R2) and the cross-validation correlation coefficient (Q2) of leave-one-out (LOO) were 0.973 and 0.950, respectively. The results demonstrated that the model was highly reliable and had good predictive ability from the point of view of statistics. From the four parameters (0C(p)(v), 2C(p)(v), C(ch),(v), 5C(p)(v)) of the model, it is known that the dominant influence factors of the retention index were the molecular structure characteristics of two-dimensional and the space factors: the chiral characteristics, the flexibility and the puckered degree of molecules for the chiral organic acids. The results showed that the new parameter mC(t)(v) had good rationality and efficiency for the retention indices of the chiral organic acids. Therefore, an effective method was provided to predict the retention indices of the chiral organic acids.
Hwang, Seonhong; Tsai, Chung-Ying; Koontz, Alicia M
2017-05-24
The purpose of this study was to test the concurrent validity and test-retest reliability of the Kinect skeleton tracking algorithm for measurement of trunk, shoulder, and elbow joint angle measurement during a wheelchair transfer task. Eight wheelchair users were recruited for this study. Joint positions were recorded simultaneously by the Kinect and Vicon motion capture systems while subjects transferred from their wheelchairs to a level bench. Shoulder, elbow, and trunk angles recorded with the Kinect system followed a similar trajectory as the angles recorded with the Vicon system with correlation coefficients that are larger than 0.71 on both sides (leading arm and trailing arm). The root mean square errors (RMSEs) ranged from 5.18 to 22.46 for the shoulder, elbow, and trunk angles. The 95% limits of agreement (LOA) for the discrepancy between the two systems exceeded the clinical significant level of 5°. For the trunk, shoulder, and elbow angles, the Kinect had very good relative reliability for the measurement of sagittal, frontal and horizontal trunk angles, as indicated by the high intraclass correlation coefficient (ICC) values (>0.90). Small standard error of the measure (SEM) values, indicating good absolute reliability, were observed for all joints except for the leading arm's shoulder joint. Relatively large minimal detectable changes (MDCs) were observed in all joint angles. The Kinect motion tracking has promising performance levels for some upper limb joints. However, more accurate measurement of the joint angles may be required. Therefore, understanding the limitations in precision and accuracy of Kinect is imperative before utilization of Kinect.
Validation of the korean-version of the nonmotor symptoms scale for Parkinson's disease.
Koh, Seong-Beom; Kim, Jae Woo; Ma, Hyeo-Il; Ahn, Tae-Beom; Cho, Jin Whan; Lee, Phil Hyu; Chung, Sun Ju; Kim, Joong-Seok; Kwon, Do Young; Baik, Jong Sam
2012-12-01
Non-motor symptoms are common in Parkinson's disease (PD), and are the primary cause of disability in many PD patients. Our aim in this study was to translate the origin non-motor symptoms scale for PD (NMSS), which was written in English, into Korean (K-NMSS), and to evaluate its reliability and validity for use with Korean-speaking patients with PD. In total, 102 patients with PD from 9 movement disorders sections of university teaching hospitals in Korea were enrolled in this study. They were assessed using the K-NMSS, the Unified Parkinson's Disease Rating Scale (UPDRS), the Korean version of the Mini-Mental Status Examination (K-MMSE), the Korean version of the Montgomery-Asberg Depression Rating Scale (K-MADS), the Epworth Sleepiness Scale (ESS), and Parkinson's Disease Questionnaire 39 (PDQ39). Test-retest reliability was assessed over a time interval of 10-14 days in all but one patient. The K-NMSS was administered to 102 patients with PD. The internal consistency and reliability of this tool was 0.742 (mean Cronbach's α-coefficient). The test-retest correlation reliability was 0.941 (Guttman split-half coefficient). There was a moderate correlation between the total K-NMSS score and the scores for UPDRS part I [Spearman's rank correlation coefficient, (rS)=0.521, p<0.001] and UPDRS part II (rS=0.464, p=0.001), but there was only a weak correlation between the total K-NMSS score and the UPDRS part III score (rS=0.288, p=0.003). The total K-NMSS score was significantly correlated with the K-MADS (rS=0.594, p<0.001), K-MMSE (rS=-0.291, p=0.003), and ESS (rS=0.348, p<0.001). The total K-NMSS score was also significantly and positively correlated with the PDQ39 score (rS=0.814, p<0.001). The K-NMSS exhibited good reliability and validity for the assessment of non-motor symptoms in Korean PD patients.
Validation of the Korean-Version of the Nonmotor Symptoms Scale for Parkinson's Disease
Koh, Seong-Beom; Kim, Jae Woo; Ma, Hyeo-Il; Ahn, Tae-Beom; Cho, Jin Whan; Lee, Phil Hyu; Chung, Sun Ju; Kim, Joong-Seok; Kwon, Do Young
2012-01-01
Background and Purpose Non-motor symptoms are common in Parkinson's disease (PD), and are the primary cause of disability in many PD patients. Our aim in this study was to translate the origin non-motor symptoms scale for PD (NMSS), which was written in English, into Korean (K-NMSS), and to evaluate its reliability and validity for use with Korean-speaking patients with PD. Methods In total, 102 patients with PD from 9 movement disorders sections of university teaching hospitals in Korea were enrolled in this study. They were assessed using the K-NMSS, the Unified Parkinson's Disease Rating Scale (UPDRS), the Korean version of the Mini-Mental Status Examination (K-MMSE), the Korean version of the Montgomery-Asberg Depression Rating Scale (K-MADS), the Epworth Sleepiness Scale (ESS), and Parkinson's Disease Questionnaire 39 (PDQ39). Test-retest reliability was assessed over a time interval of 10-14 days in all but one patient. Results The K-NMSS was administered to 102 patients with PD. The internal consistency and reliability of this tool was 0.742 (mean Cronbach's α-coefficient). The test-retest correlation reliability was 0.941 (Guttman split-half coefficient). There was a moderate correlation between the total K-NMSS score and the scores for UPDRS part I [Spearman's rank correlation coefficient, (rS)=0.521, p<0.001] and UPDRS part II (rS=0.464, p=0.001), but there was only a weak correlation between the total K-NMSS score and the UPDRS part III score (rS=0.288, p=0.003). The total K-NMSS score was significantly correlated with the K-MADS (rS=0.594, p<0.001), K-MMSE (rS=-0.291, p=0.003), and ESS (rS=0.348, p<0.001). The total K-NMSS score was also significantly and positively correlated with the PDQ39 score (rS=0.814, p<0.001). Conclusions The K-NMSS exhibited good reliability and validity for the assessment of non-motor symptoms in Korean PD patients. PMID:23323136
Super-resolution study of polymer mobility fluctuations near c*.
King, John T; Yu, Changqian; Wilson, William L; Granick, Steve
2014-09-23
Nanoscale dynamic heterogeneities in synthetic polymer solutions are detected using super-resolution optical microscopy. To this end, we map concentration fluctuations in polystyrene-toluene solutions with spatial resolution below the diffraction limit, focusing on critical fluctuations near the polymer overlap concentration, c*. Two-photon super-resolution microscopy was adapted to be applicable in an organic solvent, and a home-built STED-FCS system with stimulated emission depletion (STED) was used to perform fluorescence correlation spectroscopy (FCS). The polystyrene serving as the tracer probe (670 kg mol(-1), radius of gyration RG ≈ 35 nm, end-labeled with a bodipy derivative chromophore) was dissolved in toluene at room temperature (good solvent) and mixed with matrix polystyrene (3,840 kg mol(-1), RG ≈ 97 nm, Mw/Mn = 1.04) whose concentration was varied from dilute to more than 10c*. Whereas for dilute solutions the intensity-intensity correlation function follows a single diffusion process, it splits starting at c* to imply an additional relaxation process provided that the experimental focal area does not greatly exceed the polymer blob size. We identify the slower mode as self-diffusion and the increasingly rapid mode as correlated segment fluctuations that reflect the cooperative diffusion coefficient, Dcoop. These real-space measurements find quantitative agreement between correlation lengths inferred from dynamic measurements and those from determining the limit below which diffusion coefficients are independent of spot size. This study is considered to illustrate the potential of importing into polymer science the techniques of super-resolution imaging.
Bruscky, Dayanne Mota Veloso; Melo, Ana Caroline Cavalcanti Dela Bianca; Sarinho, Emanuel Sávio Cavalcanti
2017-01-01
To translate, adapt and validate the Itch Severity Scale to a Brazilian version (ISS-Ped) in order to measure the severity of pruritus in children and adolescents with atopic dermatitis. This is a methodological study of validation of an instrument following recommended protocols. The translated version was evaluated by a group of experts including one professional with experience in instrument validation, three English teachers, one linguistics teacher and seven allergists. After this, the scale was applied to 42 parents of children aged between 2 and 18 years old with atopic dermatitis, and 42 parents of children without pruritic diseases. Results were evaluated according to the severity of atopic dermatitis and disease control, and they were compared between groups with and without atopic dermatitis. More than 90% of the questions were clear to the parents. The ISS-Ped showed a strong positive correlation with the severity of atopic dermatitis (Pearson: 0.74; p<0.001) and a good correlation with the control of dermatitis (point-biserial correlation coefficient: 0.65; p<0.001). The scale showed excellent internal consistency (Cronbach's α: 0.96) and adequate test and retest agreement (95% confidence interval of intraclass correlation coefficient: 0.89-0.99; p<0.001). The ISS-Ped is a feasible, valid, reliable and satisfactorily equivalent. The translated scale was appropriate to assess the severity of itching in children and adolescents with eczema, allowing comparisons in the clinical practice and in the research setting.
Quality of life of patients undergoing surgery by videolaparoscopy for GERD treatment.
Andrade, Francisco José Cavalcante; de Almeida, Eliete Rodrigues; dos Santos, Maria Teresa Botti Rodrigues; Soares-Filho, Eurípedes; Lopes, João Batista; Veras e Silva, Roberto Cavalcante
2012-01-01
Gastroesophageal reflux disease is a chronic disease of high prevalence in Western countries, with negative effects on quality of life. Surgery is indicated for patients with intolerance to continuous medication, prolonged treatment or control, or in complicated forms of the disease. To evaluate the quality of life of patients undergoing surgery by videolaparoscopy for gastroesophageal reflux disease treatment. Sample comprised 43 patients of both genders (mean age = 51.4 years). For quality of life evaluation was made using the questionnaire Gastroesophageal Reflux Disease Health Related Quality of Life, translated and validated into Portuguese. Data were analyzed by Epi Info version 3.5.1, using Duncan test and Pearson's correlation coefficient, with 5% for null hypothesis (p ≤ 0.05). Over 50% of participants showed good quality of life (scores <5 of the questionnaire), more than 90% indicated satisfaction with their health. A significant positive correlation between most variables related to heartburn and the time after surgery was observed (p ≤ 0.05). Patients presented good quality of life and high level of satisfaction with their postoperative condition.
NASA Technical Reports Server (NTRS)
August, Richard; Kaza, Krishna Rao V.
1988-01-01
An investigation of the vibration, performance, flutter, and forced response of the large-scale propfan, SR7L, and its aeroelastic model, SR7A, has been performed by applying available structural and aeroelastic analytical codes and then correlating measured and calculated results. Finite element models of the blades were used to obtain modal frequencies, displacements, stresses and strains. These values were then used in conjunction with a 3-D, unsteady, lifting surface aerodynamic theory for the subsequent aeroelastic analyses of the blades. The agreement between measured and calculated frequencies and mode shapes for both models is very good. Calculated power coefficients correlate well with those measured for low advance ratios. Flutter results show that both propfans are stable at their respective design points. There is also good agreement between calculated and measured blade vibratory strains due to excitation resulting from yawed flow for the SR7A propfan. The similarity of structural and aeroelastic results show that the SR7A propfan simulates the SR7L characteristics.
Interacting hadron resonance gas model in the K -matrix formalism
NASA Astrophysics Data System (ADS)
Dash, Ashutosh; Samanta, Subhasis; Mohanty, Bedangadas
2018-05-01
An extension of hadron resonance gas (HRG) model is constructed to include interactions using relativistic virial expansion of partition function. The noninteracting part of the expansion contains all the stable baryons and mesons and the interacting part contains all the higher mass resonances which decay into two stable hadrons. The virial coefficients are related to the phase shifts which are calculated using K -matrix formalism in the present work. We have calculated various thermodynamics quantities like pressure, energy density, and entropy density of the system. A comparison of thermodynamic quantities with noninteracting HRG model, calculated using the same number of hadrons, shows that the results of the above formalism are larger. A good agreement between equation of state calculated in K -matrix formalism and lattice QCD simulations is observed. Specifically, the lattice QCD calculated interaction measure is well described in our formalism. We have also calculated second-order fluctuations and correlations of conserved charges in K -matrix formalism. We observe a good agreement of second-order fluctuations and baryon-strangeness correlation with lattice data below the crossover temperature.
Penny, William M; Steele, Harmen B; Ross, J B Alexander; Palmer, Christopher P
2017-03-01
Phospholipid bilayer nanodiscs composed of 1,2-dimyristoyl-sn-glycero-3-phosphocholine and synthetic maleic acid-styrene copolymer belts have been introduced as a pseudostationary phase (PSP) in electrokinetic chromatography and demonstrated good performance. The nanodiscs provide a suitable migration range and high theoretical plate counts. Using this nanodisc pseudostationary phase, the affinity of the bilayer structure for probe solutes was determined and characterized. Good correlation is observed between retention factors and octanol water partition coefficients for particular categories of solutes, but the general correlation is weak primarily because the nanodiscs show stronger affinity than octanol for hydrogen bond donors. This suggests that a more appropriate application of this technology is to measure and characterize interactions between solutes and lipid bilayers directly. Linear solvation energy relationship analysis of the nanodisc-solute interactions in this study demonstrates that the nanodiscs provide a solvation environment with low cohesivity and weak hydrogen bond donating ability, and provide relatively strong hydrogen bond acceptor strength. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Binding of environmental carcinogens to asbestos and mineral fibres.
Harvey, G; Pagé, M; Dumas, L
1984-01-01
A rapid method has been developed for measuring the binding capacity of asbestos and other mineral fibres for environmental carcinogens. Benzo(alpha)pyrene (B(alpha)P), nitrosonornicotine (NNN), and N-acetyl-2-aminofluorene (NAAF) were assayed in the presence of Canadian grade 4T30 chrysotile, chrysotile A, amosite, crocidolite, glass microfibres, glasswool, attapulgite, and titanium dioxide. Chrysotile binds significantly more carcinogens than the other mineral fibres. This binding assay is reproducible with coefficients of variation of less than 8% and 6% respectively for inter and intra assay. The influence of pH was also studied, and there is good correlation between the carcinogen binding and the charge of the tested mineral fibres. The in vitro cytotoxicity on macrophage like cell line P388D1 and the haemolytic activity of various mineral fibres were also measured; a good correlation was found between the binding capacity and the cytotoxicity of tested mineral fibres on P388D1 cells. These results give some explanations for the reported synergism between exposure to asbestos and the smoking habits of workers. PMID:6331497
Link prediction with node clustering coefficient
NASA Astrophysics Data System (ADS)
Wu, Zhihao; Lin, Youfang; Wang, Jing; Gregory, Steve
2016-06-01
Predicting missing links in incomplete complex networks efficiently and accurately is still a challenging problem. The recently proposed Cannistrai-Alanis-Ravai (CAR) index shows the power of local link/triangle information in improving link-prediction accuracy. Inspired by the idea of employing local link/triangle information, we propose a new similarity index with more local structure information. In our method, local link/triangle structure information can be conveyed by clustering coefficient of common-neighbors directly. The reason why clustering coefficient has good effectiveness in estimating the contribution of a common-neighbor is that it employs links existing between neighbors of a common-neighbor and these links have the same structural position with the candidate link to this common-neighbor. In our experiments, three estimators: precision, AUP and AUC are used to evaluate the accuracy of link prediction algorithms. Experimental results on ten tested networks drawn from various fields show that our new index is more effective in predicting missing links than CAR index, especially for networks with low correlation between number of common-neighbors and number of links between common-neighbors.
[Descriptive analysis of pelvic asymmetry in an asymptomatic population].
Barbosa, A C; Bonifácio, D N; Lopes, I P; Martins, F L M; Barbosa, M C S A; Barbosa, A C
2014-01-01
Pelvic tilt is clinically assessed based on its relationship with spinal conditions, but there is little evidence from the asymptomatic-population for comparison purposes. To analyze an asymptomatic population focusing,on pelvic asymmetries using photogrammetry. 92 subjects (18-35 years old) underwent marking of the anterior and posterior iliac spines and were photographed. Alcimage software was used to measure the pelvic tilt angle. Other tests included: the Kolmogorov normality test, t test, Wilcoxon test, and Pearson coefficient to measure the correlation. 11.96% of males had anteversion and 34.78% normality; 38.04% of females had anteversion and 15.22% normality. Angles between iliacs for bilateral tilt showed no difference, but a difference was seen with the predominance of one side. For unilateral tilt a difference between illacs was seen. Good correlation of predominance versus anteversion was observed, and correlation was poor for side angles. The rest showed a weak or non-significant correlation. Tilt cannot be used individually to characterize pelvic dysfunction or pathology.
NASA Astrophysics Data System (ADS)
Son, Chang-Hyo; Oh, Hoo-Kyu
2012-11-01
The condensation heat transfer characteristics for CO2 flowing in a horizontal microfin tube were investigated by experiment with respect to condensation temperature and mass flux. The test section consists of a 2,400 mm long horizontal copper tube of 4.6 mm inner diameter. The experiments were conducted at refrigerant mass flux of 400-800 kg/m2s, and saturation temperature of 20-30 °C. The main experimental results showed that annular flow was highly dominated the majority of condensation flow in the horizontal microfin tube. The condensation heat transfer coefficient increases with decreasing saturation temperature and increasing mass flux. The experimental data were compared against previous heat transfer correlations. Most correlations failed to predict the experimental data. However, the correlation by Cavallini et al. showed relatively good agreement with experimental data in the microfin tube. Therefore, a new condensation heat transfer correlation is proposed with mean and average deviations of 3.14 and -7.6 %, respectively.
Wang, Fang
2016-06-01
In order to detect and quantify asymmetry of two time series, a novel cross-correlation coefficient is proposed based on recent asymmetric detrended cross-correlation analysis (A-DXA), which we called A-DXA coefficient. The A-DXA coefficient, as an important extension of DXA coefficient ρDXA, contains two directional asymmetric cross-correlated indexes, describing upwards and downwards asymmetric cross-correlations, respectively. By using the information of directional covariance function of two time series and directional variance function of each series itself instead of power-law between the covariance function and time scale, the proposed A-DXA coefficient can well detect asymmetry between the two series no matter whether the cross-correlation is significant or not. By means of the proposed A-DXA coefficient conducted over the asymmetry for California electricity market, we found that the asymmetry between the prices and loads is not significant for daily average data in 1999 yr market (before electricity crisis) but extremely significant for those in 2000 yr market (during the crisis). To further uncover the difference of asymmetry between the years 1999 and 2000, a modified H statistic (MH) and ΔMH statistic are proposed. One of the present contributions is that the high MH values calculated for hourly data exist in majority months in 2000 market. Another important conclusion is that the cross-correlation with downwards dominates over the whole 1999 yr in contrast to the cross-correlation with upwards dominates over the 2000 yr.
Wang, Fang; Wang, Lin; Chen, Yuming
2017-08-31
In order to investigate the time-dependent cross-correlations of fine particulate (PM2.5) series among neighboring cities in Northern China, in this paper, we propose a new cross-correlation coefficient, the time-lagged q-L dependent height crosscorrelation coefficient (denoted by p q (τ, L)), which incorporates the time-lag factor and the fluctuation amplitude information into the analogous height cross-correlation analysis coefficient. Numerical tests are performed to illustrate that the newly proposed coefficient ρ q (τ, L) can be used to detect cross-correlations between two series with time lags and to identify different range of fluctuations at which two series possess cross-correlations. Applying the new coefficient to analyze the time-dependent cross-correlations of PM2.5 series between Beijing and the three neighboring cities of Tianjin, Zhangjiakou, and Baoding, we find that time lags between the PM2.5 series with larger fluctuations are longer than those between PM2.5 series withsmaller fluctuations. Our analysis also shows that cross-correlations between the PM2.5 series of two neighboring cities are significant and the time lags between two PM2.5 series of neighboring cities are significantly non-zero. These findings providenew scientific support on the view that air pollution in neighboring cities can affect one another not simultaneously but with a time lag.
Hwang, Soonshin; Noh, Yoonjeong; Choi, Yoon Jeong; Chung, Chooryung; Lee, Hye Sun
2018-01-01
Objective The aim of this study was to establish the normative data of dentofacial transverse dimensions according to the skeletal maturation stage in Korean adolescents with good occlusion, assess gender differences and determine correlations between transverse variables. Methods A total of 577 Korean subjects between ages 7 to 19 years and exhibiting skeletal Class I occlusion were categorized by skeletal maturation index (SMI) of Fishman using hand-wrist radiographs. Dentofacial transverse dimensions were assessed using posteroanterior cephalograms. Independent two-sample t-tests were used to analyze differences between genders. Pearson correlation coefficient was used to determine the correlation between transverse measurements. Results Dentofacial transverse norms relevant to skeletal maturation stages were established. The average maxillomandibular width difference and ratio at growth completion was 22.16 mm and 77.01% for males; 23.70 mm and 74.06% for females, respectively. Males had greater facial, maxillary and mandibular widths compared to females at every SMI stage. The maxillary and mandibular intermolar widths showed the strongest correlation for both sexes (r = 0.826 for males, r = 0.725 for females). Conclusions Dentofacial transverse norms of Korean adolescents were established according to developmental stage. All dentofacial widths were greater in males at growth completion. Maxillary and mandibular intermolar widths were strongly correlated. This study may serve as a guideline for the assessment of dentofacial transverse growth according to skeletal maturation stage in Korean adolescents with good occlusion. PMID:29291187
Usefulness of a Short Dietary Propensity Questionnaire in Japan.
Okuda, Nagako; Itai, Kazuyoshi; Okayama, Akira
2018-05-01
There is a growing need for nutritional education for prevention and non-pharmacological treatment of risk factors for cardiovascular diseases (CVD). We compared the results of a short dietary propensity questionnaire (SDPQ) with those from the food frequency and quantity survey (FF Quantity), which had been previously quantitatively assessed by comparison with the 24-hr dietary recall (24hr-DR), to examine the usefulness of the SDPQ. The SDPQ was designed to assess dietary propensities of 12 food/nutrients relevant to CVD risk factors. We conducted a dietary survey using the SDPQ on Japanese men and women. After 2-3 weeks, we conducted the FF Quantity survey with the same participants. For each of the 12 food/nutrient categories, the relationships between quintiles of results from the SDPQ and FF Quantity were examined. Results from 79 participants who completed both surveys were used. Spearman's correlation coefficients (r) were significant for all food/nutrient categories. Good correlations were found with alcohol (r=0.792), starchy foods (r=0.566), and milk and dairy products (r=0.687), for which good correlations between the FF Quantity and 24hr-DR had been observed previously. Moderate correlations were found for vegetables (r=0.386) and high-salt foods (r=0.505), although the FF Quantity survey poorly correlated with the 24hr-DR. The SDPQ may be useful for assessment of dietary propensities for alcohol, starchy foods, and milk and dairy products in Japan.
Amariles, Pedro; Pino-Marín, Daniel; Sabater-Hernández, Daniel; García-Jiménez, Emilio; Roig-Sánchez, Inés; Faus, María José
2016-11-01
To determine the test-retest reliability of a questionnaire, with a validation preliminary, to assess knowledge of cardiovascular risk (CVR) and cardiovascular disease in patients attending community pharmacies in Spain. To complement the external validity, establishing the relationship between an educational activity and the increase in knowledge about CVR and cardiovascular disease. Sub-analysis of a controlled clinical study, EMDADER-CV, in which a questionnaire about knowledge concerning CVR was applied at 4 different times. Spanish Community Pharmacies. There were 323 patients in the control group, from the 640 who completed the study. Intraclass correlation coefficient to assess the reliability in 3 comparisons (post-educational activity with week 16, post-educational activity with week 32, and week 16 with week 32); and the non-parametric Friedman test to establish the relationship between an oral and written educational activity with increasing knowledge. For the 323 patients in the 3 comparisons, the intraclass correlation coefficient values were 0.624; 0.608 and 0.801, respectively (fair-good to excellent reliability). So, the Friedman test showed a statistically significant relationship between educational activity and increased knowledge (p < .0001). According to the intraclass correlation coefficient, the questionnaire aimed at assessing the knowledge on CVR and cardiovascular disease has a reliability between acceptable and excellent, which added to the previous validation, shows that the instrument meets the criteria of validity and reliability. Furthermore, the questionnaire showed the ability to relate an increase in knowledge with an educational intervention, feature that complements its external validity. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Wang, Z; Wang, W H; Wang, S L; Jin, J; Song, Y W; Liu, Y P; Ren, H; Fang, H; Tang, Y; Chen, B; Qi, S N; Lu, N N; Li, N; Tang, Y; Liu, X F; Yu, Z H; Li, Y X
2016-06-23
To find phenotypic subgroups of patients with pT1-2N0 invasive breast cancer by means of cluster analysis and estimate the prognosis and clinicopathological features of these subgroups. From 1999 to 2013, 4979 patients with pT1-2N0 invasive breast cancer were recruited for hierarchical clustering analysis. Age (≤40, 41-70, 70+ years), size of primary tumor, pathological type, grade of differentiation, microvascular invasion, estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER-2) were chosen as distance metric between patients. Hierarchical cluster analysis was performed using Ward's method. Cophenetic correlation coefficient (CPCC) and Spearman correlation coefficient were used to validate clustering structures. The CPCC was 0.603. The Spearman correlation coefficient was 0.617 (P<0.001), which indicated a good fit of hierarchy to the data. A twelve-cluster model seemed to best illustrate our patient cohort. Patients in cluster 5, 9 and 12 had best prognosis and were characterized by age >40 years, smaller primary tumor, lower histologic grade, positive ER and PR status, and mainly negative HER-2. Patients in the cluster 1 and 11 had the worst prognosis, The cluster 1 was characterized by a larger tumor, higher grade and negative ER and PR status, while the cluster 11 was characterized by positive microvascular invasion. Patients in other 7 clusters had a moderate prognosis, and patients in each cluster had distinctive clinicopathological features and recurrent patterns. This study identified distinctive clinicopathologic phenotypes in a large cohort of patients with pT1-2N0 breast cancer through hierarchical clustering and revealed different prognosis. This integrative model may help physicians to make more personalized decisions regarding adjuvant therapy.
NASA Astrophysics Data System (ADS)
Cheymol, Anne; de Backer, Hugo; Josefsson, Weine; Stübi, René
2006-08-01
The Aerosol Optical Depths (AODs) retrieved from Brewer Ozone Spectrophotometer measurements with a method previously developed (Cheymol and De Backer, 2003) are now validated by comparisons between AODs from six Brewer spectrophotometers and two CSEM SPM2000 sunphotometers: two Brewer spectrophotometers 016 and 178 at Uccle in Belgium; one Brewer spectrophotometer 128 and one sunphotometer CSEM SPM2000 at Norrköping in Sweden; and three Brewer instruments 040, 072, 156 at Arosa and one CSEM SPM2000 sunphotometer at Davos in Switzerland. The comparison between AODs from Brewer spectrophotometer 128 at 320.1 nm and sunphotometer SPM2000 at 368 nm at Norrköping shows that the AODs obtained from the Brewer measurements with the Langley Plot Method (LPM) are very accurate if the neutral density filter spectral transmittances are well known: with the measured values of these filters, the correlation coefficient, the slope, and the intercept of the regression line are 0.98, 0.85 ± 0.004, and 0.02 ± 0.0014, respectively. The bias observed is mainly owing to the wavelength difference between the two instruments. The comparison between AODs from different Brewer spectrophotometers confirm that AODs will be in very good agreement if they are measured with several Brewer instruments at the same place: At Uccle, the correlation coefficient, slope, and intercept of the regression line are 0.98, 1.02 ± 0.003, and 0.06 ± 0.001, respectively; at Arosa, the comparisons between the AODs from three Brewer spectrophotometers 040, 072, and 156 give a correlation coefficient, a slope, and an intercept of the regression line above 0.94, 0.98 and below 0.04, respectively.
Lonjon, Guillaume; Ilharreborde, Brice; Odent, Thierry; Moreau, Sébastien; Glorion, Christophe; Mazda, Keyvan
2014-01-01
Outcome study to determine the internal consistency, reproducibility, and concurrent validity of the French-Canadian version of the Scoliosis Research Society 22 (SRS-22 fcv) patient questionnaire in France. To determine whether the SRS-22 fcv can be used in a population from France. The SRS-22 has been translated and validated in multiple countries, notably in the French-Canadian language in Quebec, Canada. Use of SRS-22 fcv seems appropriate for evaluating adolescent idiopathic scoliosis in France. However, French-Canadian French is noticeably different from the French spoken in France, and no study has investigated the use of a French-Canadian version of a health-quality questionnaire in another French population. The methods used for validating the SRS-22 fcv in Quebec were adopted for use with a group of 200 adolescents with idiopathic scoliosis and 60 healthy adolescents in France. Reliability and reproducibility were measured by the Cronbach α and intraclass correlation coefficient (ICC), construct validity by factorial analysis, concurrent validity by the Short-Form of the survey, and discriminant validity by analysis of variance and multivariate linear regression. In France, the SRS-22 fcv showed good global internal consistency (Cronbach α = 0.87, intraclass correlation coefficient = 0.92), a coherent factorial structure, and high correlation coefficients between the SRS-22 fcv and Short-Form of the survey (P < 0.001). However, reliability and validity were slightly less than that for the instrument's original validation and the validation of the SRS-22 fcv in Quebec. These differences could be explained by language and cultural differences. The SRS-22 fcv is relevant for use in France, but further development and validation of a specific French questionnaire remain necessary to improve the assessment of functional outcomes of adolescents with scoliosis in France. N/A.
Liu, Huayun; Yu, Juping; Chen, Yongyi; He, Pingping; Zhou, Lianqing; Tang, Xinhui; Liu, Xiangyu; Li, Xuying; Wu, Yanping; Wang, Yuhua
2016-02-01
This study aimed to examine the psychometric properties and performance of a Chinese version of the Female Sexual Function Index (FSFI) among a sample of Chinese women with cervical cancer. A cross-sectional survey design was used. The respondents included 215 women with cervical cancer in an oncology hospital in China. A translated Chinese version of the FSFI was used to investigate their sexual functioning. Psychometric testing included internal consistency reliability (Cronbach's alpha coefficient and item-total correlations), test-retest reliability, construct validity (principal component analysis via oblique rotation and confirmatory factor analysis), and variability (floor and ceiling effects). The mean score of the total scale was 20.65 ± 4.77. The Cronbach values were .94 for the total scale, .72-.90 for the domains. Test-retest correlation coefficients over 2-4 weeks were .84 (p < .05) for the total scale, .68-.83 for the subscales. Item-total correlation coefficients ranged between .47 and .83 (p < .05). A five-factor model was identified via principal component analysis and established by confirmatory factor analysis, including desire/arousal, lubrication, orgasm, satisfaction, and pain. There was no evidence of floor or ceiling effects. With good psychometric properties similar to its original English version, this Chinese version of the FSFI is demonstrated to be a reliable and valid instrument that can be used to assess sexual functioning of women with cervical cancer in China. Future research is still needed to confirm its psychometric properties and performance among a large sample. Copyright © 2015 Elsevier Ltd. All rights reserved.
Mohammadifard, Noushin; Sajjadi, Firouzeh; Maghroun, Maryam; Alikhasi, Hassan; Nilforoushzadeh, Farzaneh; Sarrafzadegan, Nizal
2015-03-01
Dietary assessment is the first step of dietary modification in community-based interventional programs. This study was performed to validate a simple food frequency questionnaire (SFFQ) for assessment of selected food items in epidemiological studies with a large sample size as well as community trails. This validation study was carried out on 264 healthy adults aged ≥ 41 years old living in 3 district central of Iran, including Isfahan, Najafabad, and Arak. Selected food intakes were assessed using a 48-item food frequency questionnaire (FFQ). The FFQ was interviewer-administered, which was completed twice; at the beginning of the study and 2 weeks thereafter. The validity of this SFFQ was examined compared to estimated amount by single 24 h dietary recall and 2 days dietary record. Validation of the FFQ was determined using Spearman correlation coefficients between daily frequency consumption of food groups as assessed by the FFQ and the qualitative amount of daily food groups intake accessed by dietary reference method was applied to evaluate validity. Intraclass correlation coefficients (ICC) were used to determine the reproducibility. Spearman correlation coefficient between the estimated amount of food groups intake by examined and reference methods ranged from 0.105 (P = 0.378) in pickles to 0.48 (P < 0.001) in plant protein. ICC for reproducibility of FFQ were between 0.47-0.69 in different food groups (P < 0.001). The designed SFFQ has a good relative validity and reproducibility for assessment of selected food groups intake. Thus, it can serve as a valid tool in epidemiological studies and clinical trial with large participants.
A spatially adaptive total variation regularization method for electrical resistance tomography
NASA Astrophysics Data System (ADS)
Song, Xizi; Xu, Yanbin; Dong, Feng
2015-12-01
The total variation (TV) regularization method has been used to solve the ill-posed inverse problem of electrical resistance tomography (ERT), owing to its good ability to preserve edges. However, the quality of the reconstructed images, especially in the flat region, is often degraded by noise. To optimize the regularization term and the regularization factor according to the spatial feature and to improve the resolution of reconstructed images, a spatially adaptive total variation (SATV) regularization method is proposed. A kind of effective spatial feature indicator named difference curvature is used to identify which region is a flat or edge region. According to different spatial features, the SATV regularization method can automatically adjust both the regularization term and regularization factor. At edge regions, the regularization term is approximate to the TV functional to preserve the edges; in flat regions, it is approximate to the first-order Tikhonov (FOT) functional to make the solution stable. Meanwhile, the adaptive regularization factor determined by the spatial feature is used to constrain the regularization strength of the SATV regularization method for different regions. Besides, a numerical scheme is adopted for the implementation of the second derivatives of difference curvature to improve the numerical stability. Several reconstruction image metrics are used to quantitatively evaluate the performance of the reconstructed results. Both simulation and experimental results indicate that, compared with the TV (mean relative error 0.288, mean correlation coefficient 0.627) and FOT (mean relative error 0.295, mean correlation coefficient 0.638) regularization methods, the proposed SATV (mean relative error 0.259, mean correlation coefficient 0.738) regularization method can endure a relatively high level of noise and improve the resolution of reconstructed images.
Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.
2014-01-01
BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281
A correlation between micro- and nano-indentation on materials irradiated by high-energy heavy ions
NASA Astrophysics Data System (ADS)
Yang, Yitao; Zhang, Chonghong; Ding, Zhaonan; Su, Changhao; Yan, Tingxing; Song, Yin; Cheng, Yuguang
2018-01-01
Hardness testing is an efficient means of assessing the mechanical properties of materials due to the small sampling volume requirement. Previous studies have established the correlation between flow stress and Vickers hardness. However, the damage layer produced by ions irradiation with low energy is too thin to perform Vickers hardness test, which is usually measured by nano-indentation. Therefore, it is necessary to correlate the Vickers hardness and nano-hardness for the convenience of assessing mechanical properties of materials under irradiation. In this study, various materials (pure nickel, nickel base alloys and oxide dispersion strengthened steel) were irradiated with high-energy heavy ions to different damage levels. After irradiation, micro- and nano-indentation were performed to characterize the change in hardness. Due to indentation size effect (ISE), the hardness was dependent of load or depth. Therefore, Nix-Gao model was used to obtain the hardness without ISE (Hv0 and Hnano_0). The determined Hv0 was plotted as a function of the corresponding Hnano_0, then a good linear relation was found between Vickers hardness and nano-hardness, and a coefficient was determined to be 81.0 ± 10.5, namely, Hv 0 = 81.0Hnano _ 0 (Hv0 with unit of kgf/mm2, Hnano_0 with unit of GPa). This correlation was based on the data from various materials, therefore it was independent of materials. Based on the established correlation and nano-indentation results, the change fraction in yield stress of Inconel 718 and pure Ni with ion irradiation was compared with that with neutron irradiation. The data of Inconel 718 with heavy ion irradiation was in good agreement with the data with neutron irradiation, which was a good demonstration for the validation of the established correlation. However, a distinctive difference in change fraction of yield stress was seen for pure Ni under heavy ion irradiation and neutron irradiation, which was attributed to the difference in samples (single crystal and polycrystalline).
Limits of the memory coefficient in measuring correlated bursts
NASA Astrophysics Data System (ADS)
Jo, Hang-Hyun; Hiraoka, Takayuki
2018-03-01
Temporal inhomogeneities in event sequences of natural and social phenomena have been characterized in terms of interevent times and correlations between interevent times. The inhomogeneities of interevent times have been extensively studied, while the correlations between interevent times, often called correlated bursts, are far from being fully understood. For measuring the correlated bursts, two relevant approaches were suggested, i.e., memory coefficient and burst size distribution. Here a burst size denotes the number of events in a bursty train detected for a given time window. Empirical analyses have revealed that the larger memory coefficient tends to be associated with the heavier tail of the burst size distribution. In particular, empirical findings in human activities appear inconsistent, such that the memory coefficient is close to 0, while burst size distributions follow a power law. In order to comprehend these observations, by assuming the conditional independence between consecutive interevent times, we derive the analytical form of the memory coefficient as a function of parameters describing interevent time and burst size distributions. Our analytical result can explain the general tendency of the larger memory coefficient being associated with the heavier tail of burst size distribution. We also find that the apparently inconsistent observations in human activities are compatible with each other, indicating that the memory coefficient has limits to measure the correlated bursts.
NASA Technical Reports Server (NTRS)
Bauschlicher, Charles W., Jr.; Ram, R. S.; Bernath, Peter F.; Parsons, C. G.; Galehouse, D.; Arnold, James O. (Technical Monitor)
2001-01-01
The spectrum of CrH has been reinvestigated in the 9000-15000/cm region using the Fourier transform spectrometer of the National Solar Observatory. The 1-0 and 1-1 bands of the A6Sigma+ - X6Sigma+ transition have been measured and improved spectroscopic constants have been determined. A value for the 2-0 band origin has been obtained from the band head using estimated spectroscopic constants. These data provide a set of much improved equilibrium vibrational and rotational constants for the A6Sigma+ state. An accurate description of the A-X transition has been obtained using a multi-reference configuration interaction approach. The inclusion of both scalar relativity and Cr 3s3p correlation are required to obtain a good description of both states. The ab initio computed Einstein coefficients and radiative lifetimes are reported.
Meteorological adjustment of yearly mean values for air pollutant concentration comparison
NASA Technical Reports Server (NTRS)
Sidik, S. M.; Neustadter, H. E.
1976-01-01
Using multiple linear regression analysis, models which estimate mean concentrations of Total Suspended Particulate (TSP), sulfur dioxide, and nitrogen dioxide as a function of several meteorologic variables, two rough economic indicators, and a simple trend in time are studied. Meteorologic data were obtained and do not include inversion heights. The goodness of fit of the estimated models is partially reflected by the squared coefficient of multiple correlation which indicates that, at the various sampling stations, the models accounted for about 23 to 47 percent of the total variance of the observed TSP concentrations. If the resulting model equations are used in place of simple overall means of the observed concentrations, there is about a 20 percent improvement in either: (1) predicting mean concentrations for specified meteorological conditions; or (2) adjusting successive yearly averages to allow for comparisons devoid of meteorological effects. An application to source identification is presented using regression coefficients of wind velocity predictor variables.
Development of a Facebook Addiction Scale.
Andreassen, Cecilie Schou; Torsheim, Torbjørn; Brunborg, Geir Scott; Pallesen, Ståle
2012-04-01
The Bergen Facebook Addiction Scale (BFAS), initially a pool of 18 items, three reflecting each of the six core elements of addiction (salience, mood modification, tolerance, withdrawal, conflict, and relapse), was constructed and administered to 423 students together with several other standardized self-report scales (Addictive Tendencies Scale, Online Sociability Scale, Facebook Attitude Scale, NEO-FFI, BIS/BAS scales, and Sleep questions). That item within each of the six addiction elements with the highest corrected item-total correlation was retained in the final scale. The factor structure of the scale was good (RMSEA = .046, CFI = .99) and coefficient alpha was .83. The 3-week test-retest reliability coefficient was .82. The scores converged with scores for other scales of Facebook activity. Also, they were positively related to Neuroticism and Extraversion, and negatively related to Conscientiousness. High scores on the new scale were associated with delayed bedtimes and rising times.
Janković, Slavenka; Vukićević, Jelica; Djordjević, Sanja; Janković, Janko; Marinković, Jelena; Erić, Miloš
2013-01-01
The Children's Dermatology Life Quality Index (CDLQI) evaluates the impact of skin diseases on the patient's quality of life. The purpose of the study was to translate and to validate the CDLQI into Serbian. The CDLQI was translated into Serbian following international recommendations for translation and cultural adaptation. The validation study was carried out on a large cohort of secondary schoolchildren who self-reported acne. Translating the CDLQI consisted of forward translation, reconciliation, back translation, back-translation review, and cognitive debriefing. The good internal consistency of the scale was demonstrated with a Cronbach alpha coefficient of 0.87. A Spearman correlation coefficient of 0.66 between the CDLQI and the Cardiff Acne Disability Index (CADI) was deemed satisfactory to demonstrate concurrent validity. The translation, cross-cultural adaptation, and psychometric qualities of the CDLQI were satisfactory, enabling its application in clinical practice and future studies.
Kheirolomoom, Azadeh; Khorasheh, Farhad; Fazelinia, Hossein
2002-01-01
Immobilization of enzymes on nonporous supports provides a suitable model for investigating the effect of external mass transfer limitation on the reaction rate in the absence of internal diffusional resistance. In this study, deacylation of penicillin G was investigated using penicillin acylase immobilized on ultrafine silica particles. Kinetic studies were performed within the low-substrate-concentration region, where the external mass transfer limitation becomes significant. To predict the apparent kinetic parameters and the overall effectiveness factor, knowledge of the external mass transfer coefficient, k(L)a, is necessary. Although various correlations exist for estimation of k(L)a, in this study, an optimization scheme was utilized to obtain this coefficient. Using the optimum values of k(L)a, the initial reaction rates were predicted and found to be in good agreement with the experimental data.
Statistical Analysis of Spectral Properties and Prosodic Parameters of Emotional Speech
NASA Astrophysics Data System (ADS)
Přibil, J.; Přibilová, A.
2009-01-01
The paper addresses reflection of microintonation and spectral properties in male and female acted emotional speech. Microintonation component of speech melody is analyzed regarding its spectral and statistical parameters. According to psychological research of emotional speech, different emotions are accompanied by different spectral noise. We control its amount by spectral flatness according to which the high frequency noise is mixed in voiced frames during cepstral speech synthesis. Our experiments are aimed at statistical analysis of cepstral coefficient values and ranges of spectral flatness in three emotions (joy, sadness, anger), and a neutral state for comparison. Calculated histograms of spectral flatness distribution are visually compared and modelled by Gamma probability distribution. Histograms of cepstral coefficient distribution are evaluated and compared using skewness and kurtosis. Achieved statistical results show good correlation comparing male and female voices for all emotional states portrayed by several Czech and Slovak professional actors.
Correlation Coefficients: Appropriate Use and Interpretation.
Schober, Patrick; Boer, Christa; Schwarte, Lothar A
2018-05-01
Correlation in the broadest sense is a measure of an association between variables. In correlated data, the change in the magnitude of 1 variable is associated with a change in the magnitude of another variable, either in the same (positive correlation) or in the opposite (negative correlation) direction. Most often, the term correlation is used in the context of a linear relationship between 2 continuous variables and expressed as Pearson product-moment correlation. The Pearson correlation coefficient is typically used for jointly normally distributed data (data that follow a bivariate normal distribution). For nonnormally distributed continuous data, for ordinal data, or for data with relevant outliers, a Spearman rank correlation can be used as a measure of a monotonic association. Both correlation coefficients are scaled such that they range from -1 to +1, where 0 indicates that there is no linear or monotonic association, and the relationship gets stronger and ultimately approaches a straight line (Pearson correlation) or a constantly increasing or decreasing curve (Spearman correlation) as the coefficient approaches an absolute value of 1. Hypothesis tests and confidence intervals can be used to address the statistical significance of the results and to estimate the strength of the relationship in the population from which the data were sampled. The aim of this tutorial is to guide researchers and clinicians in the appropriate use and interpretation of correlation coefficients.
A combined evaluation of the characteristics and acute toxicity of antibiotic wastewater.
Yu, Xin; Zuo, Jiane; Li, Ruixia; Gan, Lili; Li, Zaixing; Zhang, Fei
2014-08-01
The conventional parameters and acute toxicities of antibiotic wastewater collected from each treatment unit of an antibiotic wastewater treatment plant have been investigated. The investigation of the conventional parameters indicated that the antibiotic wastewater treatment plant performed well under the significant fluctuation in influent water quality. The results of acute toxicity indicated that the toxicity of antibiotic wastewater could be reduced by 94.3 percent on average after treatment. However, treated antibiotic effluents were still toxic to Vibrio fischeri. The toxicity of antibiotic production wastewater could be attributed to the joint effects of toxic compound mixtures in wastewater. Moreover, aerobic biological treatment processes, including sequencing batch reactor (SBR) and aerobic biofilm reactor, played the most important role in reducing toxicity by 92.4 percent. Pearson׳s correlation coefficients revealed that toxicity had a strong and positive linear correlation with organic substances, nitrogenous compounds, S(2-), volatile phenol, cyanide, As, Zn, Cd, Ni and Fe. Ammonia nitrogen (NH4(+)) was the greatest contributor to toxicity according to the stepwise regression method. The multiple regression model was a good fit for [TU50-15 min] as a function of [NH₄(+)] with the determination coefficient of 0.981. Copyright © 2014 Elsevier Inc. All rights reserved.
Inter-rater reliability of the Sødring Motor Evaluation of Stroke patients (SMES).
Halsaa, K E; Sødring, K M; Bjelland, E; Finsrud, K; Bautz-Holter, E
1999-12-01
The Sødring Motor Evaluation of Stroke patients is an instrument for physiotherapists to evaluate motor function and activities in stroke patients. The rating reflects quality as well as quantity of the patient's unassisted performance within three domains: leg, arm and gross function. The inter-rater reliability of the method was studied in a sample of 30 patients admitted to a stroke rehabilitation unit. Three therapists were involved in the study; two therapists assessed the same patient on two consecutive days in a balanced design. Cohen's weighted kappa and McNemar's test of symmetry were used as measures of item reliability, and the intraclass correlation coefficient was used to express the reliability of the sumscores. For 24 out of 32 items the weighted kappa statistic was excellent (0.75-0.98), while 7 items had a kappa statistic within the range 0.53-0.74 (fair to good). The reliability of one item was poor (0.13). The intraclass correlation coefficient for the three sumscores was 0.97, 0.91 and 0.97. We conclude that the Sødring Motor Evaluation of Stroke patients is a reliable measure of motor function in stroke patients undergoing rehabilitation.
Goel, Honey; Sinha, V R; Thareja, Suresh; Aggarwal, Saurabh; Kumar, Manoj
2011-08-30
The quinolones belong to a family of synthetic potent broad-spectrum antibiotics and particularly active against gram-negative organisms, especially Pseudomonas aeruginosa. A 3D-QSPkR approach has been used to obtain the quantitative structure pharmacokinetic relationship for a series of quinolone drugs using SOMFA. The series consisting of 28 molecules have been investigated for their pharmacokinetic performance using biological half life (t(1/2)). A statistically validated robust model for a diverse group of quinolone drugs having flexibility in structure and pharmacokinetic profile (t(1/2)) obtained using SOMFA having good cross-validated correlation coefficient r(cv)(2) (0.6847), non cross-validated correlation coefficient r(2) values (0.7310) and high F-test value (33.9663). Analysis of 3D-QSPkR models through electrostatic and shape grids provide useful information about the shape and electrostatic potential contributions on t(1/2). The analysis of SOMFA results provide an insight for the generation of novel molecular architecture of quinolones with optimal half life and improved biological profile. Copyright © 2011 Elsevier B.V. All rights reserved.
Study on fast measurement of sugar content of yogurt using Vis/NIR spectroscopy techniques
NASA Astrophysics Data System (ADS)
He, Yong; Feng, Shuijuan; Wu, Di; Li, Xiaoli
2006-09-01
In order to measuring the sugar content of yogurt rapidly, a fast measurement of sugar content of yogurt using Vis/NIR-spectroscopy techniques was established. 25 samples selected separately from five different brands of yogurt were measured by Vis/NIR-spectroscopy. The sugar content of yogurt on positions scanned by spectrum were measured by a sugar content meter. The mathematical model between sugar content and Vis/NIR spectral measurements was established and developed based on partial least squares (PLS). The correlation coefficient of sugar content based on PLS model is more than 0.894, and standard error of calibration (SEC) is 0.356, standard error of prediction (SEP) is 0.389. Through predicting the sugar content quantitatively of 35 samples of yogurt from 5 different brands, the correlation coefficient between predictive value and measured value of those samples is more than 0.934. The results show the good to excellent prediction performance. The Vis/NIR spectroscopy technique had significantly greater accuracy for determining the sugar content. It was concluded that the Vis/NIRS measurement technique seems reliable to assess the fast measurement of sugar content of yogurt, and a new method for the measurement of sugar content of yogurt was established.
Performance evaluation of Abbott CELL-DYN Ruby for routine use.
Lehto, T; Hedberg, P
2008-10-01
CELL-DYN Ruby is a new automated hematology analyzer suitable for routine use in small laboratories and as a back-up or emergency analyzer in medium- to high-volume laboratories. The analyzer was evaluated by comparing the results from the CELL-DYN((R)) Ruby with the results obtained from CELL-DYN Sapphire . Precision, linearity, and carryover between patient samples were also assessed. Precision was good at all levels for the routine cell blood count (CBC) parameters, CV% being
Guan, Wei; Cai, Wei-Xiong; Huang, Fu-Yin; Wu, Jia-Sheng
2009-10-01
To explore the application of Diminished Criminal Responsibility Rating Scale (DCRRS) to mental retardation offenders. The DCRRS was used to 121 cases of mental retardation offenders who were divided into three groups according to the degree of their diminished criminal responsibility. There were significant differences in rating score among the three groups (mild group 22.12+/-4.69, moderate group 25.50+/-5.48, major group 27.59+/-5.69), and 17 items had good correlation with the total score of the scale with the correlation coefficient from 0.289 to 0.665. Six factors were extracted by the factor analysis, and 69.392% variation could be explained. The DCRRS has rational items, its total score could show the difference among the three degree diminished criminal responsibility of mental retardation offenders.
Gandhi, Sailaxmi; Pavalur, Rajitha; Thanapal, Sivakumar; Parathasarathy, Nirmala B; Desai, Geetha; Bhola, Poornima; Philip, Mariamma; Chaturvedi, Santosh K
2014-10-01
Work benefits mental health in innumerable ways. Vocational rehabilitation can enhance self-esteem. Medication adherence can improve work performance and thereby the individuals' self-esteem. To test the hypothesis that there would be a significant correlation between medication adherence, work performance and self-esteem. A quantitative, descriptive correlational research design was adopted to invite patients attending psychiatric rehabilitation services to participate in the research. Data was collected from a convenience sample of 60 subjects using the 'Medication Adherence Rating scale', 'Griffiths work behaviour scale' and the 'Rosenberg's Self-esteem scale'. Analysis was done using spss18 with descriptive statistics, Pearsons correlation coefficient and multiple regression analysis. There were 36 males and 24 females who participated in this study. The subjects had good mean medication adherence of 8.4 ± 1.5 with median of 9.00, high mean self-esteem of 17.65 ± 2.97 with median of 18.0 and good mean work performance of 88.62 ± 22.56 with median of 93.0. Although weak and not significant, there was a positive correlation (r = 0.22, P = 0.103) between medication adherence and work performance; positive correlation between (r = 0.25, P = 0.067) medication adherence and self-esteem; positive correlation between (r = 0.136, P = 0.299) work performance and self-esteem. Multiple regression analysis showed no significant predictors for medication adherence, work performance and self-esteem among patients with psychiatric illness. Medication monitoring and strengthening of work habit can improve self-esteem thereby, strengthening hope of recovery from illness.
Onyeaso, C O
2003-04-01
To ascertain the correlation between self-esteem, orthodontic concern and orthodontic status using DAI scores in a group of Nigerian potential orthodontic patients. A cross-sectional analytical study. Secondary schools reflecting a good socio-economic spread of adolescents in the town. Randomly selected 520 junior and senior students 276 (53.1%) males and 244 (46.9%) females with mean age of 15.02 +/- 3.26 (SD) years participated in the study. Each student was asked to fill in the questionnaire on orthodontic concern and Global Negative Self-Evaluation scale (GSE) with subsequent assessment of the occlusion according to the DAI by one orthodontist. After obtaining consent, thirty students were re-examined to test intra-examiner reliability which was good (r = 0.98, P < 0.001). The correlations between self-esteem, orthodontic concern and DAI scores were tested using Spearman rank order correlation coefficient. Significant positive correlations were observed between self-esteem and orthodontic concern according to DAI treatment category needs (r = 0.274, p<0.01; r = 0.396, p<0.01; r = 0.347, p<0.05) except for the severe malocclusion group which was positive but not statistically significant (r = 0.136, p> 0.05). Significant correlation was equally noted between DAI scores and orthodontic concern (r = 0.191, p<0.01). Significant positive correlation existed between self-esteem in a group of Nigerian adolescents and their orthodontic concern as well as between their DAI scores and orthodontic concern. DAI should be a relevant and useful occlusal index for the Nigerian orthodontic population.
Pestana, R K N; Amorim, E P; Ferreira, C F; Amorim, V B O; Oliveira, L S; Ledo, C A S; Silva, S O
2011-10-25
Bananas are among the most important fruit crops worldwide, being cultivated in more than 120 countries, mainly by small-scale producers. However, short-stature high-yielding bananas presenting good agronomic characteristics are hard to find. Consequently, wind continues to damage a great number of plantations each year, leading to lodging of plants and bunch loss. Development of new cultivars through conventional genetic breeding methods is hindered by female sterility and the low number of seeds. Mutation induction seems to have great potential for the development of new cultivars. We evaluated genetic dissimilarity among putative 'Preciosa' banana mutants generated by gamma-ray irradiation, using morphoagronomic characteristics and ISSR markers. The genetic distances between the putative 'Preciosa' mutants varied from 0.21 to 0.66, with a cophenetic correlation coefficient of 0.8064. We found good variability after irradiation of 'Preciosa' bananas; this procedure could be useful for banana breeding programs aimed at developing short-stature varieties with good agronomic characteristics.
A New Protocol to Evaluate the Effect of Topical Anesthesia
List, Thomas; Mojir, Katerina; Svensson, Peter; Pigg, Maria
2014-01-01
This double-blind, placebo-controlled, randomized cross-over clinical experimental study tested the reliability, validity, and sensitivity to change of punctuate pain thresholds and self-reported pain on needle penetration. Female subjects without orofacial pain were tested in 2 sessions at 1- to 2-week intervals. The test site was the mucobuccal fold adjacent to the first upper right premolar. Active lidocaine hydrochloride 2% (Dynexan) or placebo gel was applied for 5 minutes, and sensory testing was performed before and after application. The standardized quantitative sensory test protocol included mechanical pain threshold (MPT), pressure pain threshold (PPT), mechanical pain sensitivity (MPS), and needle penetration sensitivity (NPS) assessments. Twenty-nine subjects, mean (SD) age 29.0 (10.2) years, completed the study. Test-retest reliability intraclass correlation coefficient at 10-minute intervals between examinations was MPT 0.69, PPT 0.79, MPS 0.72, and NPS 0.86. A high correlation was found between NPS and MPS (r = 0.84; P < .001), whereas NPS and PPT were not significantly correlated. The study found good to excellent test-retest reliability for all measures. None of the sensory measures detected changes in sensitivity following lidocaine 2% or placebo gel. Electronic von Frey assessments of MPT/MPS on oral mucosa have good validity. PMID:25517548
Murray, Greg; Goldstone, Eliot; Cunningham, Everarda
2007-08-01
The aim of this study was to model normal personality correlates of the predisposition(s) to bipolar disorder (BD), and in so doing explore the proposition that the tendency to bipolar depression [trait depression (T-Depression)] and the tendency to mania [trait mania (T-Mania)] can usefully be viewed as separable but correlated dimensions of BD predisposition. A well student sample (n = 176, modal age 18-25 years, 71% female) completed the NEO Personality Inventory-Revised and the General Behavior Inventory. A good-fitting model (normed chi2 = 0.60, significance of chi2 = 0.73) was identified in which T-Depression was determined solely by neuroticism, while T-Mania was determined by extraversion and (negative) agreeableness. The pathway from T-Depression to T-Mania was also significant (standardized regression weight = 0.80), with a weaker significant reciprocal path (coefficient = 0.27). A model in which bipolar vulnerability was represented as a single dimension (T-Bipolarity) also provided a good fit to the data, but provided less heuristic power. Predisposition to BD can be usefully understood in terms of two reciprocally related dimensions of vulnerability (T-Depression and T-Mania), which can be separated on the basis of their personality correlates.
A hybrid study of multiple contributors to per capita household CO2 emissions (HCEs) in China.
Qu, Jiansheng; Qin, Shanshan; Liu, Lina; Zeng, Jingjing; Bian, Yue
2016-04-01
Given the large expenditures by households on goods and services that contribute a large proportion of global CO2 emissions, increasing attention has been paid to household CO2 emissions (HCEs). However, compared with industrial CO2 emissions, efforts devoted to mitigating HCEs are relatively small. A good understanding of the effects of some driving factors (i.e., urbanization rate, per capita GDP, per capita income/disposable income, Engel coefficient, new energy ratio, carbon intensity, and household size) is urgently needed prior to considering policies for reducing HCEs. Given this, in the study, the direct and indirect per capita HCEs were quantified in rural and urban areas of China over the period 2000-2012. Correlation analysis and gray correlation analysis were initially used to identify the prime drivers of per capita HCEs. Our results showed that per capita income/disposable income, per capita GDP, urbanization rate, and household size were the most significantly correlated with per capita HCEs in rural areas. Moreover, the conjoint effects of the potential driving factors on per capita HCEs were determined by performing principal component regression analysis for all cases. Based on the combined analysis strategies, alternative polices were also examined for controlling and mitigating HCEs growth in China.
Martínez-Nova, Alfonso; Pascual Huerta, Javier; Sánchez-Rodríguez, Raquel
2008-01-01
We evaluated normal plantar pressures and studied the effect of weight, cadence, and age on forefoot plantar pressures in healthy subjects by using the Biofoot (Instituto de Biomecánica de Valencia, Valencia, Spain) in-shoe measurement system. The feet of 45 healthy subjects with no evident foot or lower-limb diseases were measured with the Biofoot in-shoe system. The forefoot was divided into seven areas: the first through fifth metatarsal heads, the hallux, and the second through fifth lesser toes. Three trials of 8 sec each were recorded twice in each subject, and the mean was used to analyze peak and mean plantar pressures. A multiple regression model including weight, age, and cadence was run for each metatarsal head, the hallux, and the lesser toes. Intraclass correlation coefficients and coefficients of variation were also calculated to assess reliability. The second metatarsal head had the greatest peak (960 kPa) and mean (585.1 kPa) pressures, followed by the third metatarsal head. Weight and cadence combined explained 18% and 23% of peak plantar pressure at the second and third metatarsal heads, respectively (P < .001). The intraclass correlation coefficient varied from 0.76 to 0.96 for all variables. The coefficient of variation between sessions ranged from 5.8% to 9.0%. The highest peak and mean plantar pressures were found at the second and third metatarsal heads in healthy subjects. Weight, cadence, and age explained a low variability of this pressure pattern. The Biofoot in-shoe system has good reliability to measure plantar pressures. These data will have implications for the understanding of normal foot biomechanics and its determinants.
Tread wear and footprint geometrical characters of truck bus radial tires
NASA Astrophysics Data System (ADS)
Liang, Chen; Wang, Guolin; An, Dengfeng; Ma, Yinwei
2013-05-01
Wear and mileage performance are the foremost performances for truck bus radial (TBR) tires. There are a lot of researches about the tire wear performance as well as the contact patch phenomenon by using finite element analysis (FEA) method or testing. But there is little published data on the correlations between the footprint geometry and the tread wear performance of tires. In this paper, an experiment on tire-ground performance of TBR tires is carried out by using Tekscan. The real-time changes of contact-area pressure distribution that occurred during the process of continuous load and unload are recorded. Three types of tires that act differently in behavior under normal usage are analyzed. A new method of researching in tire tread wear, which focuses on the geometrical characters of the footprint, is put forward. The experimental results of the three tires are described by using footprint geometrical characters. On the basis of studying the changing laws of footprint geometrical characters during the loading process and considering consumer survey and factory feedback information, the correlations between the geometrical character of footprints and tread destruction form are built. The analyzed results show that a greater contact area coefficient and a steady coefficient of contact result in a better wear performance for TBR tires. The footprint-shape coefficient changing laws in the process of loading are found to have a very good coincidence with the tread wear of the three types of tires. Tires with a smaller footprint-shape coefficient are likely to have an average tread wear while avoiding the shoulder wear first. The proposed research provides a new solution to predict tire-ground performance at the point of footprint and several useful references for improving tire design.