Reilly, Gayatri; Melamud, Alexander; Lipscomb, Peter; Toussaint, Brian
2015-09-01
To evaluate whether patients with macular pucker (epiretinal membrane [ERM]) and good preoperative visual acuity (20/50 or better) benefit from small-gauge pars plana vitrectomy with membrane peeling. Retrospective chart review of eyes undergoing small-gauge pars plana vitrectomy for ERM. Inclusion criterion was impaired visual acuity (20/50 or better) due to ERM. Exclusion criteria were preoperative visual acuity of 20/60 or worse, previous surgery (other than uncomplicated cataract surgery), and any documented evidence of macular or corneal disease that would limit visual potential. The main outcome measure was final visual acuity. Secondary outcomes included the role of internal limiting membrane peeling, and the effect of preoperative cystoid macular edema and internal limiting membrane peeling on visual acuity. One hundred and forty eyes met inclusion criteria of which 94% underwent 25-gauge vitrectomy (remainder had 23-gauge). There was a statistically significant improvement in final vision with the mean preoperative visual acuity of 0.305 logMAR (20/40) and 1-year visual acuity of 0.250 logMAR (20/35) (P = 0.0167). Cataract formation in phakic patients had a significant effect on the final visual outcome. Fifty-six of 63 patients (89%) in the phakic cohort developed a visually significant cataract by study end. The mean time to recommendation of cataract surgery was 8.4 months. Thirty-eight eyes (27%) had preoperative cystoid macular edema. Fifty-nine eyes (42%) underwent internal limiting membrane peeling. Neither one of these secondary outcome measures had a significant effect on the final visual outcome. Pars plana vitrectomy is both efficacious and safe an option for patients with ERMs and good preoperative vision. Eyes with an ERM and vision 20/50 or better had a statistically significant improvement in the final visual outcome after small-gauge pars plana vitrectomy surgery. As with large-gauge vitrectomy, cataract formation occurred in most phakic eyes within the first year after surgery.
Clinical characteristics in 53 patients with cat scratch optic neuropathy.
Chi, Sulene L; Stinnett, Sandra; Eggenberger, Eric; Foroozan, Rod; Golnik, Karl; Lee, Michael S; Bhatti, M Tariq
2012-01-01
To describe the clinical manifestations and to identify risk factors associated with visual outcome in a large cohort of patients with cat scratch optic neuropathy (CSON). Multicenter, retrospective chart review. Fifty-three patients (62 eyes) with serologically positive CSON from 5 academic neuro-ophthalmology services evaluated over an 11-year period. Institutional review board/ethics committee approval was obtained. Data from medical record charts were collected to detail the clinical manifestations and to analyze visual outcome metrics. Generalized estimating equations and logistic regression analysis were used in the statistical analysis. Six patients (9 eyes) were excluded from visual outcome statistical analysis because of a lack of follow-up. Demographic information, symptoms at presentation, clinical characteristics, length of follow-up, treatment used, and visual acuity (at presentation and final follow-up). Mean patient age was 27.8 years (range, 8-65 years). Mean follow-up time was 170.8 days (range, 1-1482 days). Simultaneous bilateral involvement occurred in 9 (17%) of 53 patients. Visual acuity on presentation ranged from 20/20 to counting fingers (mean, 20/160). Sixty-eight percent of eyes retained a visual acuity of 20/40 or better at final follow-up (defined as favorable visual outcome). Sixty-seven percent of patients endorsed a history of cat or kitten scratch. Neuroretinitis (macular star) developed in 28 eyes (45%). Only 5 patients had significant visual complications (branch retinal artery occlusion, macular hole, and corneal decompensation). Neither patient age nor any other factor except good initial visual acuity and absence of systemic symptoms was associated with a favorable visual outcome. There was no association between visual acuity at final follow-up and systemic antibiotic or steroid use. Patients with CSON have a good overall visual prognosis. Good visual acuity at presentation was associated with a favorable visual outcome. The absence of a macular star does not exclude the possibility of CSON. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
2010-01-01
good for visual survey through the morning and into the early afternoon. The visual team got a good workout on the data logging program and GIS...Peter Tyack SSC Pacific San Diego, CA 92152–5001 TD 3243 Office of Naval Research 875 N. Randolph Street , Suite 1425
Prognostic factors in Acanthamoeba keratitis.
Kaiserman, Igor; Bahar, Irit; McAllum, Penny; Srinivasan, Sathish; Elbaz, Uri; Slomovic, Allan R; Rootman, David S
2012-06-01
To assess the prognostic factors influencing visual prognosis and length of treatment after acanthamoeba keratitis (AK). Forty-two AK eyes of 41 patients treated between 1999 and 2006 were included. A diagnosis of AK was made on the basis of culture results with a corresponding clinical presentation. We calculated the prognostic effect of the various factors on final visual acuity and the length of treatment. Multivariate regression analysis was used to adjust for the simultaneous effects of the various prognostic factors. Mean follow-up was 19.7 ± 21.0 months. Sixty-four percent of cases had > 1 identified risk factor for AK, the most common risk factor being contact lens wear (92.9% of eyes). At presentation, median best spectacle corrected visual acuity (BCVA) was 20/200 (20/30 to Hand Motion [HM]) that improved after treatment to 20/50 (20/20 to Counting Fingers [CF]). Infection acquired by swimming or related to contact lenses had significantly better final BCVA (p = 0.03 and p = 0.007, respectively). Neuritis and pseudodendrites were also associated with better final BCVA (p = 0.04 and p = 0.05, respectively). Having had an epithelial defect on presentation and having been treated with topical steroid were associated with worse final best spectacle corrected visual acuity (BSCVA) (p = 0.0006 and p = 0.04). Multivariate regression analysis found a good initial visual acuity (p = 0.002), infections related to swimming (p = 0.01), the absence of an epithelial defect (p = 0.03), having been treated with chlorhexidine (p = 0.05), and not having receive steroids (p = 0.003) to significantly forecast a good final BCVA. We identified several prognostic factors that can help clinicians evaluate the expected visual damage of the AK infection and thus tailor treatment accordingly. Copyright © 2012 Canadian Ophthalmological Society. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhao, Yiqun; Wang, Zhihui
2015-12-01
The Internet of things (IOT) is a kind of intelligent networks which can be used to locate, track, identify and supervise people and objects. One of important core technologies of intelligent visual internet of things ( IVIOT) is the intelligent visual tag system. In this paper, a research is done into visual feature extraction and establishment of visual tags of the human face based on ORL face database. Firstly, we use the principal component analysis (PCA) algorithm for face feature extraction, then adopt the support vector machine (SVM) for classifying and face recognition, finally establish a visual tag for face which is already classified. We conducted a experiment focused on a group of people face images, the result show that the proposed algorithm have good performance, and can show the visual tag of objects conveniently.
NASA Astrophysics Data System (ADS)
Xie, Xian-Hua; Yu, Zu-Guo; Ma, Yuan-Lin; Han, Guo-Sheng; Anh, Vo
2017-09-01
There has been a growing interest in visualization of metagenomic data. The present study focuses on the visualization of metagenomic data using inter-nucleotide distances profile. We first convert the fragment sequences into inter-nucleotide distances profiles. Then we analyze these profiles by principal component analysis. Finally the principal components are used to obtain the 2-D scattered plot according to their source of species. We name our method as inter-nucleotide distances profiles (INP) method. Our method is evaluated on three benchmark data sets used in previous published papers. Our results demonstrate that the INP method is good, alternative and efficient for visualization of metagenomic data.
Cat-scratch disease: ocular manifestations and treatment outcome.
Habot-Wilner, Zohar; Trivizki, Omer; Goldstein, Michaella; Kesler, Anat; Shulman, Shiri; Horowitz, Josepha; Amer, Radgonde; David, Ran; Ben-Arie-Weintrob, Yael; Bakshi, Erez; Almog, Yehoshua; Sartani, Gil; Vishnevskia-Dai, Vicktoria; Kramer, Michal; Bar, Asaf; Kehat, Rinat; Ephros, Moshe; Giladi, Michael
2018-03-05
To characterize cat-scratch disease (CSD) ocular manifestations and visual outcome and evaluate the effect of systemic antibiotics and corticosteroids on final visual acuity (VA). Multicentre retrospective cohort study. Medical records of 86 patients with ocular disease (107 eyes) of 3222 patients identified in a national CSD surveillance study were reviewed. Mean age was 35.1 ± 14.2 years. Median follow-up was 20 weeks (range 1-806 weeks). Of 94/107 (88%) eyes with swollen disc, 60 (64%) had neuroretinitis at presentation, 14 (15%) developed neuroretinitis during follow-up, and 20 (21%) were diagnosed with inflammatory disc oedema. Optic nerve head lesion, uveitis, optic neuropathy and retinal vessel occlusion were found in 43 (40%), 38 (36%), 34 (33%) and 8 (7%) eyes, respectively. Good VA (better than 20/40), moderate vision loss (20/40-20/200) and severe vision loss (worse than 20/200) were found in 26/79 (33%), 35/79 (44%) and 18/79 (23%) eyes at baseline and in 63/79 (80%), 11/79 (14%) and 5/79 (6%) eyes at final follow-up, respectively (p < 0.001). Significant VA improvement (defined as improvement of ≥3 Snellen lines at final follow-up compared to baseline) occurred in 12/24 (50%) eyes treated with antibiotics compared with 14/16 (88%) eyes treated with antibiotics and corticosteroids (p = 0.02). Multivariate logistic regression was suggestive of the same association (odds ratio 7.0; 95% CI 1.3-37.7; p = 0.024). Optic nerve head lesion is a common and unique manifestation of ocular CSD. Most patients improved and had final good VA. Combined antibiotics and corticosteroid treatment was associated with a better visual outcome. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Design of novel non-contact multimedia controller for disability by using visual stimulus.
Pan, Jeng-Shyang; Lo, Chi-Chun; Tsai, Shang-Ho; Lin, Bor-Shyh
2015-12-01
The design of a novel non-contact multimedia controller is proposed in this study. Nowadays, multimedia controllers are generally used by patients and nursing assistants in the hospital. Conventional multimedia controllers usually involve in manual operation or other physical movements. However, it is more difficult for the disabled patients to operate the conventional multimedia controller by themselves; they might totally depend on others. Different from other multimedia controllers, the proposed system provides a novel concept of controlling multimedia via visual stimuli, without manual operation. The disabled patients can easily operate the proposed multimedia system by focusing on the control icons of a visual stimulus device, where a commercial tablet is used as the visual stimulus device. Moreover, a wearable and wireless electroencephalogram (EEG) acquisition device is also designed and implemented to easily monitor the user's EEG signals in daily life. Finally, the proposed system has been validated. The experimental result shows that the proposed system can effectively measure and extract the EEG feature related to visual stimuli, and its information transfer rate is also good. Therefore, the proposed non-contact multimedia controller exactly provides a good prototype of novel multimedia controlling scheme. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Simulation and visualization of fundamental optics phenomenon by LabVIEW
NASA Astrophysics Data System (ADS)
Lyu, Bohan
2017-08-01
Most instructors teach complex phenomenon by equation and static illustration without interactive multimedia. Students usually memorize phenomenon by taking note. However, only note or complex formula can not make user visualize the phenomenon of the photonics system. LabVIEW is a good tool for in automatic measurement. However, the simplicity of coding in LabVIEW makes it not only suit for automatic measurement, but also suitable for simulation and visualization of fundamental optics phenomenon. In this paper, five simple optics phenomenon will be discuss and simulation with LabVIEW. They are Snell's Law, Hermite-Gaussian beam transverse mode, square and circular aperture diffraction, polarization wave and Poincare sphere, and finally Fabry-Perrot etalon in spectrum domain.
Efficacy of autologous platelets in macular hole surgery.
Konstantinidis, Aristeidis; Hero, Mark; Nanos, Panagiotis; Panos, Georgios D
2013-01-01
The introduction of optical coherence tomography has allowed accurate measurement of the size of macular holes. A retrospective consecutive review was performed of 21 patients undergoing macular hole repair with vitrectomy, gas tamponade, and autologous platelet injection and we assessed the effect of macular hole parameters on anatomic and functional outcomes. We looked at the demographic features, final visual outcome, and anatomical closure. Twenty-one patients were included in the study. They underwent routine vitrectomy with gas tamponade (C3F8) and injection of autologous platelets. All patients were advised to maintain a facedown posture for 2 weeks. Anatomical closure was confirmed in all cases and 20 out of 21 of patients had improved postoperative visual acuity by two or more lines. In our series, the macular hole dimensions did not have much effect on the final results. The use of autologous platelets and strict facedown posture seems to be the deciding factor in good anatomical and visual outcome irrespective of macular hole dimensions.
Epidemiology and clinical outcome of intraocular foreign bodies in Hong Kong: a 13-year review.
Liu, Candice C H; Tong, Justin M K; Li, Patrick S H; Li, Kenneth K W
2017-02-01
The purpose of this study was to describe the epidemiology, visual outcome and prognostic factors of intraocular foreign body (IOFB) injuries in a tertiary centre in Hong Kong. A retrospective review of 21 eyes in 21 patients with IOFB that presented to United Christian Hospital from January 2001 to July 2014 was performed. IOFB represented 16 % of all open-globe traumas. There was a high male predominance (90 %). The mean age was 42. Work-related injuries (86 %) were the main cause, where only 10.5 % had eye protection. Hammering was the commonest mechanism of injury (43 %). Most IOFBs were metallic (67 %). The IOFB was found in the anterior segment in 31 % and posterior segment in 69 %. 57 % presented with an initial visual acuity of ≥0.1, and up to 24 % of patients had an initial visual acuity of better than or equal to 0.5. Most cases (76 %) received prompt surgical intervention within 24 h, and there was a low (0 %) endophthalmitis rate. Forty-eight percent had an improvement in visual acuity, defined as final visual acuity more than or equal to 2 lines of improvement from initial visual acuity, and 48 % attained a final visual acuity of better than or equal to 0.5. One case underwent evisceration. A smaller IOFB size (<5 mm) was associated with a good final visual acuity of better than or equal to 0.5 (p = 0.048). It was also found that a posterior segment IOFB was more likely to give a final VA of less than 0.5 (p = 0.035). IOFB remains a significant complication of work-related injuries in Hong Kong. This is the first local study that explores the epidemiology of IOFB injuries in Hong Kong. The favourable visual outcome and low endophthalmitis rate may be related to early removal of IOFB. Despite legal ordinances for mandatory eye protection, the uptake of eye protection was low.
Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan
2014-01-01
This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs. PMID:25587878
Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan
2014-11-26
This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs.
Optical devices in highly myopic eyes with low vision: a prospective study.
Scassa, C; Cupo, G; Bruno, M; Iervolino, R; Capozzi, S; Tempesta, C; Giusti, C
2012-01-01
To compare, in relation to the cause of visual impairment, the possibility of rehabilitation, the corrective systems already in use and the finally prescribed optical devices in highly myopic patients with low vision. Some considerations about the rehabilitation of these subjects, especially in relation to their different pathologies, have also been made. 25 highly myopic subjects were enrolled. We evaluated both visual acuity and retinal sensitivity by Scanning Laser Ophthalmoscope (SLO) microperimetry. 20 patients (80%) were rehabilitated by means of monocular optical devices while five patients (20%) were rehabilitated binocularly. We found a good correlation between visual acuity and retinal sensitivity only when the macular pathology did not induce large areas of chorioretinal atrophy that cause lack of stabilization of the preferential retinal locus. In fact, the best results in reading and performing daily visual tasks were obtained by maximizing the residual vision in patients with retinal sensitivity greater than 10 dB. A well circumscribed area of absolute scotoma with a defined new retinal fixation locus could be considered as a positive predictive factor for the final rehabilitation process. A more careful evaluation of visual acuity, retinal sensitivity and preferential fixation locus is necessary in order to prescribe the best optical devices to patients with low vision, thus reducing the impact of the disability on their daily life.
A comparative study of visual reaction time in table tennis players and healthy controls.
Bhabhor, Mahesh K; Vidja, Kalpesh; Bhanderi, Priti; Dodhia, Shital; Kathrotia, Rajesh; Joshi, Varsha
2013-01-01
Visual reaction time is time required to response to visual stimuli. The present study was conducted to measure visual reaction time in 209 subjects, 50 table tennis (TT) players and 159 healthy controls. The visual reaction time was measured by the direct RT computerized software in healthy controls and table tennis players. Simple visual reaction time was measured. During the reaction time testing, visual stimuli were given for eighteen times and average reaction time was taken as the final reaction time. The study shows that table tennis players had faster reaction time than healthy controls. On multivariate analysis, it was found that TT players had 74.121 sec (95% CI 98.8 and 49.4 sec) faster reaction time compared to non-TT players of same age and BMI. Also playing TT has a profound influence on visual reaction time than BMI. Our study concluded that persons involved in sports are having good reaction time as compared to controls. These results support the view that playing of table tennis is beneficial to eye-hand reaction time, improve the concentration and alertness.
Lin, Yu-Cheng; Ho, Kuo-Jung
2018-01-01
To evaluate the association between night-shift work exposure and visual health, this cross-sectional study utilized visual acuity, a surrogate measure for visual function, as a parameter, and performed an analysis comparing visual acuity between daytime and nighttime employees in an electronics manufacturing company. Data of personal histories, occupational records, physical examinations and blood tests was obtained from the electronic health records of workers. The total of 8280 workers including 3098 women and 5182 men, wearing their own daily used eyeglasses, were included in the final analysis. The mean age of the sample population was 34.7 years old (standard deviation = 5.4 years). All workers were divided into 3 work categories - consistent daytime worker (CDW), day-shift worker (DSW) and night-shift worker (NSW). The check-up results of glasses-corrected visual acuity (c-VA) were utilized to classify individuals as good (≥ 1.2, both eyes) and inadequate (< 0.8, the better eye) c-VA. Consistent daytime workers had the highest rate of good c-VA (42.5% vs. 25.1% DSW and 21.1% NSW, p = 0.047). Night-shift workers had the highest rate of inadequate c-VA (CDW, DSW and NSW: 2.6%, 6.2%, and 7.6%, p = 0.03) among all employees. After controlling for covariates, NSW were found at an increased risk for inadequate c-VA (adjusted odds ratio (ORa) = 2.7, 95% confidence interval (CI): 2.0-3.6, vs. CDW), and less likely to have good c-VA (ORa = 0.4, 95% CI: 0.4-0.5, vs. CDW). Night-shift work is moderately associated with compromised visual acuity of employees in this electronics manufacturing company. Int J Occup Med Environ Health 2018;31(1):71-79. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Optimal linguistic expression in negotiations depends on visual appearance
Kwon, Jinhwan; Tamada, Hikaru; Hirahara, Yumi
2018-01-01
We investigate the influence of the visual appearance of a negotiator on persuasiveness within the context of negotiations. Psychological experiments were conducted to quantitatively analyze the relationship between visual appearance and the use of language. Male and female participants were shown three female and male photographs, respectively. They were asked to report how they felt about each photograph using a seven-point semantic differential (SD) scale for six affective factors (positive impression, extraversion, intelligence, conscientiousness, emotional stability, and agreeableness). Participants then answered how they felt about each negotiation scenario (they were presented with pictures and a situation combined with negotiation sentences) using a seven-point SD scale for seven affective factors (positive impression, extraversion, intelligence, conscientiousness, emotional stability, agreeableness, and degree of persuasion). Two experiments were conducted using different participant groups depending on the negotiation situations. Photographs with good or bad appearances were found to show high or low degrees of persuasion, respectively. A multiple regression equation was obtained, indicating the importance of the three language factors (euphemistic, honorific, and sympathy expressions) to impressions made during negotiation. The result shows that there are optimal negotiation sentences based on various negotiation factors, such as visual appearance and use of language. For example, persons with good appearance might worsen their impression during negotiations by using certain language, although their initial impression was positive, and persons with bad appearance could effectively improve their impressions in negotiations through their use of language, although the final impressions of their negotiation counterpart might still be more negative than those for persons with good appearance. In contrast, the impressions made by persons of normal appearance were not easily affected by their use of language. The results of the present study have significant implications for future studies of effective negotiation strategies considering visual appearance as well as gender. PMID:29621361
Optimal linguistic expression in negotiations depends on visual appearance.
Sakamoto, Maki; Kwon, Jinhwan; Tamada, Hikaru; Hirahara, Yumi
2018-01-01
We investigate the influence of the visual appearance of a negotiator on persuasiveness within the context of negotiations. Psychological experiments were conducted to quantitatively analyze the relationship between visual appearance and the use of language. Male and female participants were shown three female and male photographs, respectively. They were asked to report how they felt about each photograph using a seven-point semantic differential (SD) scale for six affective factors (positive impression, extraversion, intelligence, conscientiousness, emotional stability, and agreeableness). Participants then answered how they felt about each negotiation scenario (they were presented with pictures and a situation combined with negotiation sentences) using a seven-point SD scale for seven affective factors (positive impression, extraversion, intelligence, conscientiousness, emotional stability, agreeableness, and degree of persuasion). Two experiments were conducted using different participant groups depending on the negotiation situations. Photographs with good or bad appearances were found to show high or low degrees of persuasion, respectively. A multiple regression equation was obtained, indicating the importance of the three language factors (euphemistic, honorific, and sympathy expressions) to impressions made during negotiation. The result shows that there are optimal negotiation sentences based on various negotiation factors, such as visual appearance and use of language. For example, persons with good appearance might worsen their impression during negotiations by using certain language, although their initial impression was positive, and persons with bad appearance could effectively improve their impressions in negotiations through their use of language, although the final impressions of their negotiation counterpart might still be more negative than those for persons with good appearance. In contrast, the impressions made by persons of normal appearance were not easily affected by their use of language. The results of the present study have significant implications for future studies of effective negotiation strategies considering visual appearance as well as gender.
An adhered-particle analysis system based on concave points
NASA Astrophysics Data System (ADS)
Wang, Wencheng; Guan, Fengnian; Feng, Lin
2018-04-01
Particles adhered together will influence the image analysis in computer vision system. In this paper, a method based on concave point is designed. First, corner detection algorithm is adopted to obtain a rough estimation of potential concave points after image segmentation. Then, it computes the area ratio of the candidates to accurately localize the final separation points. Finally, it uses the separation points of each particle and the neighboring pixels to estimate the original particles before adhesion and provides estimated profile images. The experimental results have shown that this approach can provide good results that match the human visual cognitive mechanism.
ERIC Educational Resources Information Center
Di Francesco, Loretta; Smith, Philip D., Jr.
1971-01-01
This evaluation of two programs of materials used in introductory French classes tests two basic hypotheses: (1) pretests are good predictors of subsequent French achievement at the junior high school level, and (2) students in different programs will achieve to the same degree on a final French test. Results of the groups using the "audiolingual"…
Five-year study of ocular injuries due to fireworks in India.
Malik, Archana; Bhala, Soniya; Arya, Sudesh K; Sood, Sunandan; Narang, Subina
2013-08-01
To study the demographic profile, cause, type and severity of ocular injuries, their complications and final visual outcome following fireworks around the time of Deepawali in India. Case records of patients who presented with firework-related injuries during 2005-2009 at the time of Deepawali were reviewed. Data with respect to demographic profile of patients, cause and time of injury, time of presentation and types of intervention were analyzed. Visual acuity at presentation and final follow-up, anterior and posterior segment findings, and any diagnostic and surgical interventions carried out were noted. One hundred and one patients presented with firework-related ocular injuries, of which 77.5 % were male. The mean age was 17.60 ± 11.9 years, with 54 % being ≤14 years of age. The mean time of presentation was 8.9 h. Seventeen patients had open globe injury (OGI) and 84 had closed globe injury (CGI). Fountains were the most common cause of CGI and bullet bombs were the most common cause of OGI. Mean log MAR visual acuity at presentation was 0.64 and 1.22 and at last follow-up was 0.09 and 0.58 for CGI and OGI, respectively (p < 0.05). Patients with CGI had a better visual outcome. Three patients with OGI developed permanent blindness. Factors associated with poor visual outcome included poor initial visual acuity, OGI, intraocular foreign body (IOFB), retinal detachment and development of endophthalmitis. Firework injuries were seen mostly in males and children. Poor visual outcome was associated with poor initial visual acuity, OGI, IOFB, retinal detachment and development of endophthalmitis, while most patients with CGI regained good vision.
Mashima, Yukihiko; Kigasawa, Kazuteru; Shinoda, Kei; Wakakura, Masato; Oguchi, Yoshihisa
2017-10-18
Patients with Leber hereditary optic neuropathy (LHON) have a progressive decrease of their visual acuity which can deteriorate to <0.1. Some patients can have a partial recovery of their vision in one or both eyes. One prognostic factor associated with a recovery of vision is an early-age onset. The purpose of this study was to determine other clinical factors that are predictive of a good visual recovery. Sixty-one Japanese LHON patients, with the 11,778 mutation and a mean age of 23.1 ± 12.1 years at the onset, were studied. All patients were initially examined at an acute stage of LHON and were followed for 3 to 10 years. At 1 year after the onset, the lowest visual acuity was <0.1 in all eyes. We studied the following parameters of patients with/without a final visual acuity of ≥ 0.2: sex; heavy consumption of cigarettes and alcohol; taking idebenone; mean age at onset; mean lowest visual acuity; and distribution of the lowest and the final visual acuity. Fifteen (24.6%) of the 61 patients or 25 (20.5%) of the 122 eyes had a recovery of their visual acuity to ≥ 0.2. The mean age at onset of these 15 patients with visual recovery to ≥ 0.2 was 17.5 ± 7.7 years, and that of the 46 patients without visual recovery to ≥ 0.2 was 25.0 ± 12.8 years (P = 0.02, Mann-Whitney U test). The mean lowest visual acuity of the 25 eyes with visual recovery ≥ 0.2 was 0.04, and that of the 97 eyes without visual recovery to ≥ 0.2 was 0.015 (P < 0.001, Mann-Whitney U test). Fifty percent (15/30) of the eyes whose lowest visual acuity was ≥ 0.04 during 1 year after the onset had a visual recovery to ≥ 0.2, while 11% (10/92) of the eyes whose the lowest visual acuity was ≤ 0.03 had a visual recovery to ≥ 0.2 (P < 0.001, χ 2 test). There were no significant differences in the other clinical factors. A final visual acuity of ≥ 0.2 was associated with a less severe reduction of the visual acuity at 1 year after the onset. Our findings can be used to predict the visual prognosis in LHON patients.
Automatic and Objective Assessment of Alternating Tapping Performance in Parkinson's Disease
Memedi, Mevludin; Khan, Taha; Grenholm, Peter; Nyholm, Dag; Westin, Jerker
2013-01-01
This paper presents the development and evaluation of a method for enabling quantitative and automatic scoring of alternating tapping performance of patients with Parkinson's disease (PD). Ten healthy elderly subjects and 95 patients in different clinical stages of PD have utilized a touch-pad handheld computer to perform alternate tapping tests in their home environments. First, a neurologist used a web-based system to visually assess impairments in four tapping dimensions (‘speed’, ‘accuracy’, ‘fatigue’ and ‘arrhythmia’) and a global tapping severity (GTS). Second, tapping signals were processed with time series analysis and statistical methods to derive 24 quantitative parameters. Third, principal component analysis was used to reduce the dimensions of these parameters and to obtain scores for the four dimensions. Finally, a logistic regression classifier was trained using a 10-fold stratified cross-validation to map the reduced parameters to the corresponding visually assessed GTS scores. Results showed that the computed scores correlated well to visually assessed scores and were significantly different across Unified Parkinson's Disease Rating Scale scores of upper limb motor performance. In addition, they had good internal consistency, had good ability to discriminate between healthy elderly and patients in different disease stages, had good sensitivity to treatment interventions and could reflect the natural disease progression over time. In conclusion, the automatic method can be useful to objectively assess the tapping performance of PD patients and can be included in telemedicine tools for remote monitoring of tapping. PMID:24351667
Automatic and objective assessment of alternating tapping performance in Parkinson's disease.
Memedi, Mevludin; Khan, Taha; Grenholm, Peter; Nyholm, Dag; Westin, Jerker
2013-12-09
This paper presents the development and evaluation of a method for enabling quantitative and automatic scoring of alternating tapping performance of patients with Parkinson's disease (PD). Ten healthy elderly subjects and 95 patients in different clinical stages of PD have utilized a touch-pad handheld computer to perform alternate tapping tests in their home environments. First, a neurologist used a web-based system to visually assess impairments in four tapping dimensions ('speed', 'accuracy', 'fatigue' and 'arrhythmia') and a global tapping severity (GTS). Second, tapping signals were processed with time series analysis and statistical methods to derive 24 quantitative parameters. Third, principal component analysis was used to reduce the dimensions of these parameters and to obtain scores for the four dimensions. Finally, a logistic regression classifier was trained using a 10-fold stratified cross-validation to map the reduced parameters to the corresponding visually assessed GTS scores. Results showed that the computed scores correlated well to visually assessed scores and were significantly different across Unified Parkinson's Disease Rating Scale scores of upper limb motor performance. In addition, they had good internal consistency, had good ability to discriminate between healthy elderly and patients in different disease stages, had good sensitivity to treatment interventions and could reflect the natural disease progression over time. In conclusion, the automatic method can be useful to objectively assess the tapping performance of PD patients and can be included in telemedicine tools for remote monitoring of tapping.
Moreira Neto, Carlos Augusto; Moreira Junior, Carlos Augusto
2013-01-01
To evaluate 5 patients with serous macular detachment due to optic disc pit that were submitted to pars plana vitrectomy and were followed for at least 7 years. Patients were submitted to pars plana vitrectomy, posterior hyaloid removal, autologous serum injection and gas-fluid exchange, without laser photocoagulation, and were evaluated pre and post-operatively with visual acuity and Amsler grid testing, retinography, and recently, with autofluorescence imaging and high resolution OCT. All 5 eyes improved visual acuity significantly following the surgical procedure maintaining good vision throughout the follow-up period. Mean pre-operative visual acuity was 20/400 and final visual acuity was 20/27 with a mean follow-up time of 13.6 years. No recurrences of serous detachments were observed. OCT examinations demonstrated an attached retina up to the margin of the pit. Serous macular detachments due to optic disc pits were adequately treated with pars plana vitrectomy and gas fluid exchange, without the need for laser photocoagulation, maintaining excellent visual results for a long period of time.
High resolution pituitary gland MRI at 7.0 tesla: a clinical evaluation in Cushing's disease.
de Rotte, Alexandra A J; Groenewegen, Amy; Rutgers, Dik R; Witkamp, Theo; Zelissen, Pierre M J; Meijer, F J Anton; van Lindert, Erik J; Hermus, Ad; Luijten, Peter R; Hendrikse, Jeroen
2016-01-01
To evaluate the detection of pituitary lesions at 7.0 T compared to 1.5 T MRI in 16 patients with clinically and biochemically proven Cushing's disease. In seven patients, no lesion was detected on the initial 1.5 T MRI, and in nine patients it was uncertain whether there was a lesion. Firstly, two readers assessed both 1.5 T and 7.0 T MRI examinations unpaired in a random order for the presence of lesions. Consensus reading with a third neuroradiologist was used to define final lesions in all MRIs. Secondly, surgical outcome was evaluated. A comparison was made between the lesions visualized with MRI and the lesions found during surgery in 9/16 patients. The interobserver agreement for lesion detection was good at 1.5 T MRI (κ = 0.69) and 7.0 T MRI (κ = 0.62). In five patients, both the 1.5 T and 7.0 T MRI enabled visualization of a lesion on the correct side of the pituitary gland. In three patients, 7.0 T MRI detected a lesion on the correct side of the pituitary gland, while no lesion was visible at 1.5 T MRI. The interobserver agreement of image assessment for 7.0 T MRI in patients with Cushing's disease was good, and lesions were detected more accurately with 7.0 T MRI. Interobserver agreement for lesion detection on 1.5 T MRI was good; Interobserver agreement for lesion detection on 7.0 T MRI was good; 7.0 T enabled confirmation of unclear lesions at 1.5 T; 7.0 T enabled visualization of lesions not visible at 1.5 T.
Kherani, Saleema; Scott, Adrienne W; Wenick, Adam S; Zimmer-Galler, Ingrid; Brady, Christopher J; Sodhi, Akrit; Meyerle, Catherine; Solomon, Sharon D; Shaukat, Rimsha; Channa, Roomasa; Adeyemo, Olukemi; Handa, James T; Wang, Jiangxia; Campochiaro, Peter A
2018-05-01
To identify factors influencing visual outcome in patients with neovascular age-related macular degeneration (NVAMD) and subfoveal hemorrhage (SFH) treated with anti-vascular endothelial growth factor (VEGF) agents. Retrospective case series. Anti-VEGF-treated eyes with SFH > 1 disc area (DA) were identified (n = 16) and changes in visual acuity (VA) and central subfield thickness (CST) from baseline to last follow-up, along with SFH area, thickness, minimum distance from fovea to SFH border, and time to resolution, were determined. At baseline, mean (± standard error of the mean) size and thickness of SFH were 14.9 ± 2.8 DA and 386.6 ± 46.9 μm, and mean Snellen VA and CST were 20/250 and 591.7 ± 57.0 μm. Median follow-up was 47.6 months. While more than 50% of patients had VA ≤ 20/200 at baseline and all time points through week 48, the percentage of patients with VA ≥ 20/50 increased to 30%-40% at months 6 and 12 and remained stable through month 48. Spearman rank correlation demonstrated 2 independent variables that correlated with good visual outcome, smaller area of SFH at baseline (r = -0.630; P = .009), and high frequency of anti-VEGF injections (r = 0.646; P = .007). In exceptional patients with good visual outcome despite large baseline SFH, shortest distance between the fovea and hemorrhage border significantly correlated with baseline VA (r = -0.503, P = .047) and final VA (r = -0.575, P = .02). Patients with NVAMD and thick SFH, but short distance between fovea and uninvolved retina, can have good visual outcomes when given frequent anti-VEGF injections. Copyright © 2018 Elsevier Inc. All rights reserved.
Implementation of ICARE learning model using visualization animation on biotechnology course
NASA Astrophysics Data System (ADS)
Hidayat, Habibi
2017-12-01
ICARE is a learning model that directly ensure the students to actively participate in the learning process using animation media visualization. ICARE have five key elements of learning experience from children and adult that is introduction, connection, application, reflection and extension. The use of Icare system to ensure that participants have opportunity to apply what have been they learned. So that, the message delivered by lecture to students can be understood and recorded by students in a long time. Learning model that was deemed capable of improving learning outcomes and interest to learn in following learning process Biotechnology with applying the ICARE learning model using visualization animation. This learning model have been giving motivation to participate in the learning process and learning outcomes obtained becomes more increased than before. From the results of student learning in subjects Biotechnology by applying the ICARE learning model using Visualization Animation can improving study results of student from the average value of middle test amounted to 70.98 with the percentage of 75% increased value of final test to be 71.57 with the percentage of 68.63%. The interest to learn from students more increasing visits of student activities at each cycle, namely the first cycle obtained average value by 33.5 with enough category. The second cycle is obtained an average value of 36.5 to good category and third cycle the average value of 36.5 with a student activity to good category.
Web-based visual analysis for high-throughput genomics
2013-01-01
Background Visualization plays an essential role in genomics research by making it possible to observe correlations and trends in large datasets as well as communicate findings to others. Visual analysis, which combines visualization with analysis tools to enable seamless use of both approaches for scientific investigation, offers a powerful method for performing complex genomic analyses. However, there are numerous challenges that arise when creating rich, interactive Web-based visualizations/visual analysis applications for high-throughput genomics. These challenges include managing data flow from Web server to Web browser, integrating analysis tools and visualizations, and sharing visualizations with colleagues. Results We have created a platform simplifies the creation of Web-based visualization/visual analysis applications for high-throughput genomics. This platform provides components that make it simple to efficiently query very large datasets, draw common representations of genomic data, integrate with analysis tools, and share or publish fully interactive visualizations. Using this platform, we have created a Circos-style genome-wide viewer, a generic scatter plot for correlation analysis, an interactive phylogenetic tree, a scalable genome browser for next-generation sequencing data, and an application for systematically exploring tool parameter spaces to find good parameter values. All visualizations are interactive and fully customizable. The platform is integrated with the Galaxy (http://galaxyproject.org) genomics workbench, making it easy to integrate new visual applications into Galaxy. Conclusions Visualization and visual analysis play an important role in high-throughput genomics experiments, and approaches are needed to make it easier to create applications for these activities. Our framework provides a foundation for creating Web-based visualizations and integrating them into Galaxy. Finally, the visualizations we have created using the framework are useful tools for high-throughput genomics experiments. PMID:23758618
Visualization of 3-D tensor fields
NASA Technical Reports Server (NTRS)
Hesselink, L.
1996-01-01
Second-order tensor fields have applications in many different areas of physics, such as general relativity and fluid mechanics. The wealth of multivariate information in tensor fields makes them more complex and abstract than scalar and vector fields. Visualization is a good technique for scientists to gain new insights from them. Visualizing a 3-D continuous tensor field is equivalent to simultaneously visualizing its three eigenvector fields. In the past, research has been conducted in the area of two-dimensional tensor fields. It was shown that degenerate points, defined as points where eigenvalues are equal to each other, are the basic singularities underlying the topology of tensor fields. Moreover, it was shown that eigenvectors never cross each other except at degenerate points. Since we live in a three-dimensional world, it is important for us to understand the underlying physics of this world. In this report, we describe a new method for locating degenerate points along with the conditions for classifying them in three-dimensional space. Finally, we discuss some topological features of three-dimensional tensor fields, and interpret topological patterns in terms of physical properties.
de Farias, Charles C; Allemann, Norma; Gomes, José Á P
2016-04-01
There are few studies comparing different surgical procedures for the treatment of corneal thinning. Lamellar corneal transplantation (LCT) has been reported to be efficient, but its results can be jeopardized by allograft rejection, opacification, or high astigmatism. Amniotic membrane transplantation (AMT) has been considered a good alternative, but it is not as resistant as LCT and the tissue can be reabsorbed after surgery. A prospective, randomized, interventional, and comparative study of consecutive patients with corneal thinning over 6 months was performed. Ophthalmological examination was performed before transplant surgery and then repeated 1, 7, 15, 30, 90, and 180 days after surgery and ultrasound biomicroscopy was performed before and then 30, 90, and 180 days after surgery to assess corneal thinning. Herpes simplex infection was the main cause of corneal thinning (9 eyes), followed by surgery (cataract, glaucoma, 5 cases), rheumatoid arthritis (1), chemical burn (1), perforating trauma (1), previous band keratopathy treatment (1), and Stevens-Johnson syndrome (1). Although all patients showed significant increase in final thickness in the area of thinning, it was higher in those submitted to LCT at 180 days postoperatively. Regardless of the surgical technique, all patients showed epithelialization. Patients undergoing AMT showed an 89% decrease in neovascularization. Final corrected distance visual acuity was better in patients submitted to AMT. LCT proved to be the best option for treating corneal thinning. AMT represents an alternative that allows good visual recovery but does not restore corneal thickness as efficiently as LCT.
Designing and Validation a Visual Fatigue Questionnaire for Video Display Terminals Operators
Rajabi-Vardanjani, Hassan; Habibi, Ehsanollah; Pourabdian, Siyamak; Dehghan, Habibollah; Maracy, Mohammad Reza
2014-01-01
Background: Along with the rapid growth of technology its related tools such as computer, monitors and video display terminals (VDTs) grow as well. Based on the studies, the most common complaint reported is of the VDT users. Methods: This study attempts to design a proper tool to assess the visual fatigue of the VDT users. First draft of the questionnaire was prepared after a thorough study on the books, papers and similar questionnaires. The validity and reliability of the questionnaire was confirmed using the content validity index (CVI) beside that of the Cronbach's Coefficient Alpha. Then, a cross-sectional study was carried out on 248 of the VDT users in different professions. A theoretical model with four categories of symptoms of visual fatigue was derived from the previous studies and questionnaires. Having used the AMOS16 software, the construct validity of the questionnaire was evaluated using the confirmatory factor analysis. The correlation co-efficiency of the internal domains was calculated using the SPSS 11.5 software. To assess the quality check index and determining the visual fatigue levels, visual fatigue of the VDT users was measured by the questionnaire and visual fatigue meter (VFM) device. Cut-off points were identified by receiver operating characteristic curves. Results: CVI and reliability co-efficiency were both equal to 0.75. Model fit indices including root mean of squared error approximation, goodness of fit index and adjusted goodness of fit index were obtained 0.026, 0.96 and 0.92 respectfully. The correlation between the results measured with the questionnaire and VFM-90.1 device was −0.87. Cut-off points of the questionnaire were 0.65, 2.36 and 3.88. The confirmed questionnaire consists of four main areas: Eye strain (4 questions), visual impairment (5 questions) and the surface impairment of the eye (3 questions) and the out of eye problems (3 questions). Conclusions: The visual fatigue questionnaire contains 15 questions and has a very remarkable validity and reliability. Using this questionnaire and its findings, one will be able to identify, assess and finally prevent the effective factors of VDT users’ visual fatigue. PMID:25104995
Dhoble, Pankaja; Khodifad, Ashish
2018-01-01
To study the outcomes of combined cataract extraction with pars plana vitrectomy (PPV) and metallic intraocular foreign body (IOFB) removal through a sclerocorneal tunnel using the "magnetic handshake" technique. A retrospective review. Retrospective review of case records of 14 patients from 2010 to 2016 with metallic IOFB and traumatic cataract was performed. Cataract extraction was combined with PPV. Two intraocular magnets (IOMs) introduced through 20-gauge vitrectomy port and sclerocorneal tunnel helped achieve safe delivery of IOFB outside the globe by the "magnetic handshake" technique. All patients were males with a mean age of 33.04 years. A final best corrected visual acuity (BCVA) of 20/60 or better was noted in 10 (71.42%) of 14 patients. Final reattachment with more than 1 surgery was achieved in 13 (92.85%) patients. Postoperative complications included retinal detachment (RD) and phthisis bulbi in 1 (14.28%) patient each. Combined cataract extraction with PPV and metallic IOFB removal through sclerocorneal tunnel using the "magnet handshake" technique gives good visual and surgical outcomes. Copyright 2017 Asia-Pacific Academy of Ophthalmology.
Galetta, Steven L.; Villoslada, Pablo; Levin, Netta; Shindler, Kenneth; Ishikawa, Hiroshi; Parr, Edward; Cadavid, Diego
2015-01-01
Idiopathic demyelinating optic neuritis (ON) most commonly presents as acute unilateral vision loss and eye pain and is frequently associated with multiple sclerosis. Although emphasis is often placed on the good recovery of high-contrast visual acuity, persistent deficits are frequently observed in other aspects of vision, including contrast sensitivity, visual field testing, color vision, motion perception, and vision-related quality of life. Persistent and profound structural and functional changes are often revealed by imaging and electrophysiologic techniques, including optical coherence tomography, visual-evoked potentials, and nonconventional MRI. These abnormalities can impair patients' abilities to perform daily activities (e.g., driving, working) so they have important implications for patients' quality of life. In this article, we review the sequelae from ON, including clinical, structural, and functional changes and their interrelationships. The unmet needs in each of these areas are considered and the progress made toward meeting those needs is examined. Finally, we provide an overview of past and present investigational approaches for disease modification in ON. PMID:26236761
Building conservation base on assessment of facade quality on Basuki Rachmat Street, Malang
NASA Astrophysics Data System (ADS)
Kurniawan, E. B.; Putri, R. Y. A.; Wardhani, D. K.
2017-06-01
Visual quality covers aspects of imageability which is associated with visual system and the element of distinction. Within a visual system of specific area, the physical quality may lead to a strong image. Here, the physical quality is one of important that make urban aesthetic. Build a discussion toward visual system of urban area, this paper aim is to identify the influencing factors in defining the façade’s visual quality of heritage buildings at Jend. Basuki Rahmat Street, Malang City, East Java-Indonesia. This Street is a main road of Malang city center that was built by Dutch colonial government. It was designed by IR. Thomas Kartsten. It was known as one of Malang area that have good visual quality. In order to idenfity the influencing factors, this paper conducts Multiple linear regression as a tools of analysis. The examined potential factors are resulted from of architecture and urban design expert’s assessment to each building’s segment at Jend. Basuki Rahmat. Finally, this paper reveals that the influencing factors are color, rhythm, and proportion. This is demonstrated by the results model: Visual quality (Y) = 0.304 + 0.21 Colors(X5) + 0.221 rhythm (X6) + 0.304 proportion (X7). Furthermore, the recommendation of the building facade will be made based on this model and study of historical and typology building in Basuki Rachmat Street.
CANDELS Visual Classifications: Scheme, Data Release, and First Results
NASA Technical Reports Server (NTRS)
Kartaltepe, Jeyhan S.; Mozena, Mark; Kocevski, Dale; McIntosh, Daniel H.; Lotz, Jennifer; Bell, Eric F.; Faber, Sandy; Ferguson, Henry; Koo, David; Bassett, Robert;
2014-01-01
We have undertaken an ambitious program to visually classify all galaxies in the five CANDELS fields down to H <24.5 involving the dedicated efforts of 65 individual classifiers. Once completed, we expect to have detailed morphological classifications for over 50,000 galaxies spanning 0 < z < 4 over all the fields. Here, we present our detailed visual classification scheme, which was designed to cover a wide range of CANDELS science goals. This scheme includes the basic Hubble sequence types, but also includes a detailed look at mergers and interactions, the clumpiness of galaxies, k-corrections, and a variety of other structural properties. In this paper, we focus on the first field to be completed - GOODS-S, which has been classified at various depths. The wide area coverage spanning the full field (wide+deep+ERS) includes 7634 galaxies that have been classified by at least three different people. In the deep area of the field, 2534 galaxies have been classified by at least five different people at three different depths. With this paper, we release to the public all of the visual classifications in GOODS-S along with the Perl/Tk GUI that we developed to classify galaxies. We present our initial results here, including an analysis of our internal consistency and comparisons among multiple classifiers as well as a comparison to the Sersic index. We find that the level of agreement among classifiers is quite good and depends on both the galaxy magnitude and the galaxy type, with disks showing the highest level of agreement and irregulars the lowest. A comparison of our classifications with the Sersic index and restframe colors shows a clear separation between disk and spheroid populations. Finally, we explore morphological k-corrections between the V-band and H-band observations and find that a small fraction (84 galaxies in total) are classified as being very different between these two bands. These galaxies typically have very clumpy and extended morphology or are very faint in the V-band.
Barli, Onder; Bilgili, Bilsen; Dane, Senol
2006-10-01
The associations of sex and eyedness of consumers in a market and the market's lighting and wall color with price attraction and perceived quality of goods and the inside visual appeal were studied using an inventory after shopping by 440 men and 478 women, 20 to 60 years old (M = 29.3, SD = 10.2). Two lights (soft and bright) and 4 colors (blue, yellow, green, and red) and neutral light (white) were used. Women rated the prices of goods more attractive compared to men. In the total sample, left-eye preferents rated visual appeal higher compared to right-eye preferents. Bright light was associated with higher visual appeal than soft light. Green was associated with the highest inside visual appeal and perceived quality of goods, which may be due to its intermediate wavelength.
Beyond Recipe: Leading Edges for Teaching Spelling.
ERIC Educational Resources Information Center
Garmston, Robert; Zimmerman, Diane
A good spelling teacher teaches by "taste" rather than by "recipe": instead of strictly adhering to procedural outlines, good teachers alter their lessons according to students' needs. In addition, good teachers: (1) recognize the importance of visualization for spelling; (2) understand the two kinds of visualization--for…
Colyer, Marcus H; Weber, Eric D; Weichel, Eric D; Dick, John S B; Bower, Kraig S; Ward, Thomas P; Haller, Julia A
2007-08-01
To report the long-term follow-up results of intraocular foreign body (IOFB) removal at Walter Reed Army Medical Center during Operation Iraqi Freedom and Operation Enduring Freedom from February 2003 through November 2005 and to determine the prognostic factors for visual outcome in this patient population. Retrospective, noncomparative, interventional case series. Seventy-nine eyes of 70 United States military soldiers deployed in support of operations Iraqi Freedom and Enduring Freedom sustained IOFB injuries and subsequently were treated at the Walter Reed Army Medical Center with a minimum of 6 months of follow-up. The principal procedure performed was 20-gauge 3-port vitrectomy with IOFB removal through limbal or pars plana incision. Final visual acuity, rate of proliferative vitreoretinopathy, rate of endophthalmitis. Average patient age was 27 years, with an average of 331 days of postoperative follow-up. Average IOFB size was 3.7 mm (range, 0.1-20 mm). Median time to IOFB removal was 21 days (mean, 38 days; range, 2-661 days). Mean preoperative visual acuity was 20/400 (1.36 logarithm of mean angle of resolution [logMAR] units) and mean final visual acuity was 20/120 (0.75 logMAR). Of the patients, 53.4% achieved visual acuity of 20/40 or better, whereas 77.5% achieved visual acuity of better than 20/200. There were no cases of endophthalmitis (0/79 eyes; 95% confidence interval, 0%-3.1%), siderosis bulbi, or sympathetic ophthalmia. Among the eyes, 10.3% evolved to no light perception or had been enucleated by the 6-month follow-up visit. Poor visual outcome correlated with extensive intraocular injury (P<0.032). Seventeen of 79 eyes (21%) experienced proliferative vitreoretinopathy. Proliferative vitreoretinopathy correlated with poor initial vision (hand movements or worse; P = 0.035) and extensive intraocular injury (P<0.001). Timing of vitrectomy did not correlate with visual outcome. The most common systemic antibiotic administered was levofloxacin, whereas the most common topical antibiotic administered was moxifloxacin. Poor visual outcome and postoperative complication rates are related to extensive intraocular injury. Delayed IOFB removal with a combination of systemic and topical antibiotic coverage can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects.
Visual Graphics for Human Rights, Social Justice, Democracy and the Public Good
ERIC Educational Resources Information Center
Nanackchand, Vedant; Berman, Kim
2012-01-01
The value of human rights in a democratic South Africa is constantly threatened and often waived for nefarious reasons. We contend that the use of visual graphics among incoming university visual art students provides a mode of engagement that helps to inculcate awareness of human rights, social responsibility, and the public good in South African…
The Statistics of Visual Representation
NASA Technical Reports Server (NTRS)
Jobson, Daniel J.; Rahman, Zia-Ur; Woodell, Glenn A.
2002-01-01
The experience of retinex image processing has prompted us to reconsider fundamental aspects of imaging and image processing. Foremost is the idea that a good visual representation requires a non-linear transformation of the recorded (approximately linear) image data. Further, this transformation appears to converge on a specific distribution. Here we investigate the connection between numerical and visual phenomena. Specifically the questions explored are: (1) Is there a well-defined consistent statistical character associated with good visual representations? (2) Does there exist an ideal visual image? And (3) what are its statistical properties?
NASA Astrophysics Data System (ADS)
Gao, Simon S.; Liu, Li; Bailey, Steven T.; Flaxel, Christina J.; Huang, David; Li, Dengwang; Jia, Yali
2016-07-01
Quantification of choroidal neovascularization (CNV) as visualized by optical coherence tomography angiography (OCTA) may have importance clinically when diagnosing or tracking disease. Here, we present an automated algorithm to quantify the vessel skeleton of CNV as vessel length. Initial segmentation of the CNV on en face angiograms was achieved using saliency-based detection and thresholding. A level set method was then used to refine vessel edges. Finally, a skeleton algorithm was applied to identify vessel centerlines. The algorithm was tested on nine OCTA scans from participants with CNV and comparisons of the algorithm's output to manual delineation showed good agreement.
Johari, Masoumeh; Abdollahzadeh, Milad; Esmaeili, Farzad; Sakhamanesh, Vahideh
2018-01-01
Dental cone beam computed tomography (CBCT) images suffer from severe metal artifacts. These artifacts degrade the quality of acquired image and in some cases make it unsuitable to use. Streaking artifacts and cavities around teeth are the main reason of degradation. In this article, we have proposed a new artifact reduction algorithm which has three parallel components. The first component extracts teeth based on the modeling of image histogram with a Gaussian mixture model. Striking artifact reduction component reduces artifacts using converting image into the polar domain and applying morphological filtering. The third component fills cavities through a simple but effective morphological filtering operation. Finally, results of these three components are combined into a fusion step to create a visually good image which is more compatible to human visual system. Results show that the proposed algorithm reduces artifacts of dental CBCT images and produces clean images.
Johari, Masoumeh; Abdollahzadeh, Milad; Esmaeili, Farzad; Sakhamanesh, Vahideh
2018-01-01
Background: Dental cone beam computed tomography (CBCT) images suffer from severe metal artifacts. These artifacts degrade the quality of acquired image and in some cases make it unsuitable to use. Streaking artifacts and cavities around teeth are the main reason of degradation. Methods: In this article, we have proposed a new artifact reduction algorithm which has three parallel components. The first component extracts teeth based on the modeling of image histogram with a Gaussian mixture model. Striking artifact reduction component reduces artifacts using converting image into the polar domain and applying morphological filtering. The third component fills cavities through a simple but effective morphological filtering operation. Results: Finally, results of these three components are combined into a fusion step to create a visually good image which is more compatible to human visual system. Conclusions: Results show that the proposed algorithm reduces artifacts of dental CBCT images and produces clean images. PMID:29535920
Yotsukura, Erisa; Torii, Hidemasa; Saiki, Megumi; Negishi, Kazuno; Tsubota, Kazuo
2016-03-01
To evaluate the effect of neodymium:YAG (Nd:YAG) laser capsulotomy on the visual function in patients with posterior capsule opacification (PCO) and good visual acuity. Keio University Hospital, Tokyo, Japan. Observational case series. Eyes were evaluated that had previous cataract surgery with a clinical diagnosis of PCO requiring Nd:YAG laser capsulotomy regardless of a good corrected distance visual acuity (CDVA) (at least 20/20). The CDVA, 10% low contrast visual acuity (LCVA), wavefront aberrations from the 3rd to 6th order, and retinal straylight were measured before and after Nd:YAG laser capsulotomy. The study included 16 eyes of 16 patients (10 men, 6 women; mean age 69.5 years ± 9.3 [SD]). The mean CDVA, LCVA, and straylight after Nd:YAG laser capsulotomy improved significantly (P < .05). The root mean square (RMS) of the 3rd Zernike coefficients (S3) and the RMS of the total higher-order aberrations (HOAs) from the 3rd to 6th order decreased significantly after capsulotomy (P < .05). The straylight correlated significantly with the total HOAs (r = 0.727, P = .002) and S3 (r = 0.748, P = .001) before capsulotomy. Subjective symptoms resolved after capsulotomy in all cases. Neodymium:YAG laser capsulotomy enabled a significant improvement in visual function even in patients with PCO with good visual acuity. Straylight measurements might be useful to determine the indications for Nd:YAG laser capsulotomy when patients report visual disturbances without decreased visual acuity. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Ranjan, Manish; Boutet, Alexandre; Xu, David S; Lozano, Christopher S; Kumar, Rajeev; Fasano, Alfonso; Kucharczyk, Walter; Lozano, Andres M
2018-05-30
The visualization of the subthalamic nucleus (STN) on magnetic resonance imaging (MRI) is variable. Studies of the contribution of patient-related factors and intrinsic brain volumetrics to STN visualization have not been reported previously. To assess the visualization of the STN during deep brain stimulation (DBS) surgery in a clinical setting. Eighty-two patients undergoing pre-operative MRI to plan for STN DBS for Parkinson disease were retrospectively studied. The visualization of the STN and its borders was assessed and scored by 3 independent observers using a 4-point ordinal scale (from 0 = not seen to 3 = excellent visualization). This measure was then correlated with the patients' clinical information and brain volumes. The mean STN visualization scores were 1.68 and 1.63 for the right and left STN, respectively, with a good interobserver reliability (intraclass correlation coefficient: 0.744). Older age and decreased white matter volume were negatively correlated with STN visualization (p < 0.05). STN visualization is only fair to good on routine MRI with good concordance of interindividual rating. Advancing age and decreased white matter are associated with poor visualization of the STN. Knowledge about factors contributing to poor visualization of the STN could alert a surgeon to modify the imaging strategy to optimize surgical targeting. © 2018 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Santosa, H.; Ernawati, J.; Wulandari, L. D.
2018-03-01
The visual aesthetic experience in urban spaces is important in establishing a comfortable and satisfying experience for the community. The embodiment of a good visual image of urban space will encourage the emergence of positive perceptions and meanings stimulating the community to produce a good reaction to its urban space. Moreover, to establish a Good Governance in urban planning and design, it is necessary to boost and promote a community participation in the process of controlling the visual quality of urban space through the visual quality evaluation on urban street corridors. This study is an early stage as part of the development of ‘Landscape Visual Planning System’ on the commercial street corridor in Malang. Accordingly, the research aims to evaluate the physical characteristics and the public preferences of the spatial and visual aspects in five provincial road corridors in Malang. This study employs a field survey methods, and an environmental aesthetics approach through semantic differential method. The result of the identification of physical characteristics and the assessment of public preferences on the spatial and visual aspects of the five provincial streets serve as the basis for constructing the 3d interactive simulation scenarios in the Landscape Visual Planning System.
Keshavarz, Behrang; Campos, Jennifer L; DeLucia, Patricia R; Oberfeld, Daniel
2017-04-01
Estimating time to contact (TTC) involves multiple sensory systems, including vision and audition. Previous findings suggested that the ratio of an object's instantaneous optical size/sound intensity to its instantaneous rate of change in optical size/sound intensity (τ) drives TTC judgments. Other evidence has shown that heuristic-based cues are used, including final optical size or final sound pressure level. Most previous studies have used decontextualized and unfamiliar stimuli (e.g., geometric shapes on a blank background). Here we evaluated TTC estimates by using a traffic scene with an approaching vehicle to evaluate the weights of visual and auditory TTC cues under more realistic conditions. Younger (18-39 years) and older (65+ years) participants made TTC estimates in three sensory conditions: visual-only, auditory-only, and audio-visual. Stimuli were presented within an immersive virtual-reality environment, and cue weights were calculated for both visual cues (e.g., visual τ, final optical size) and auditory cues (e.g., auditory τ, final sound pressure level). The results demonstrated the use of visual τ as well as heuristic cues in the visual-only condition. TTC estimates in the auditory-only condition, however, were primarily based on an auditory heuristic cue (final sound pressure level), rather than on auditory τ. In the audio-visual condition, the visual cues dominated overall, with the highest weight being assigned to visual τ by younger adults, and a more equal weighting of visual τ and heuristic cues in older adults. Overall, better characterizing the effects of combined sensory inputs, stimulus characteristics, and age on the cues used to estimate TTC will provide important insights into how these factors may affect everyday behavior.
CANDELS Visual Classifications: Scheme, Data Release, and First Results
NASA Astrophysics Data System (ADS)
Kartaltepe, Jeyhan S.; Mozena, Mark; Kocevski, Dale; McIntosh, Daniel H.; Lotz, Jennifer; Bell, Eric F.; Faber, Sandy; Ferguson, Harry; Koo, David; Bassett, Robert; Bernyk, Maksym; Blancato, Kirsten; Bournaud, Frederic; Cassata, Paolo; Castellano, Marco; Cheung, Edmond; Conselice, Christopher J.; Croton, Darren; Dahlen, Tomas; de Mello, Duilia F.; DeGroot, Laura; Donley, Jennifer; Guedes, Javiera; Grogin, Norman; Hathi, Nimish; Hilton, Matt; Hollon, Brett; Koekemoer, Anton; Liu, Nick; Lucas, Ray A.; Martig, Marie; McGrath, Elizabeth; McPartland, Conor; Mobasher, Bahram; Morlock, Alice; O'Leary, Erin; Peth, Mike; Pforr, Janine; Pillepich, Annalisa; Rosario, David; Soto, Emmaris; Straughn, Amber; Telford, Olivia; Sunnquist, Ben; Trump, Jonathan; Weiner, Benjamin; Wuyts, Stijn; Inami, Hanae; Kassin, Susan; Lani, Caterina; Poole, Gregory B.; Rizer, Zachary
2015-11-01
We have undertaken an ambitious program to visually classify all galaxies in the five CANDELS fields down to H < 24.5 involving the dedicated efforts of over 65 individual classifiers. Once completed, we expect to have detailed morphological classifications for over 50,000 galaxies spanning 0 < z < 4 over all the fields, with classifications from 3 to 5 independent classifiers for each galaxy. Here, we present our detailed visual classification scheme, which was designed to cover a wide range of CANDELS science goals. This scheme includes the basic Hubble sequence types, but also includes a detailed look at mergers and interactions, the clumpiness of galaxies, k-corrections, and a variety of other structural properties. In this paper, we focus on the first field to be completed—GOODS-S, which has been classified at various depths. The wide area coverage spanning the full field (wide+deep+ERS) includes 7634 galaxies that have been classified by at least three different people. In the deep area of the field, 2534 galaxies have been classified by at least five different people at three different depths. With this paper, we release to the public all of the visual classifications in GOODS-S along with the Perl/Tk GUI that we developed to classify galaxies. We present our initial results here, including an analysis of our internal consistency and comparisons among multiple classifiers as well as a comparison to the Sérsic index. We find that the level of agreement among classifiers is quite good (>70% across the full magnitude range) and depends on both the galaxy magnitude and the galaxy type, with disks showing the highest level of agreement (>50%) and irregulars the lowest (<10%). A comparison of our classifications with the Sérsic index and rest-frame colors shows a clear separation between disk and spheroid populations. Finally, we explore morphological k-corrections between the V-band and H-band observations and find that a small fraction (84 galaxies in total) are classified as being very different between these two bands. These galaxies typically have very clumpy and extended morphology or are very faint in the V-band.
Ughi, Giovanni J; Adriaenssens, Tom; Desmet, Walter; D’hooge, Jan
2012-01-01
Intravascular optical coherence tomography (IV-OCT) is an imaging modality that can be used for the assessment of intracoronary stents. Recent publications pointed to the fact that 3D visualizations have potential advantages compared to conventional 2D representations. However, 3D imaging still requires a time consuming manual procedure not suitable for on-line application during coronary interventions. We propose an algorithm for a rapid and fully automatic 3D visualization of IV-OCT pullbacks. IV-OCT images are first processed for the segmentation of the different structures. This also allows for automatic pullback calibration. Then, according to the segmentation results, different structures are depicted with different colors to visualize the vessel wall, the stent and the guide-wire in details. Final 3D rendering results are obtained through the use of a commercial 3D DICOM viewer. Manual analysis was used as ground-truth for the validation of the segmentation algorithms. A correlation value of 0.99 and good limits of agreement (Bland Altman statistics) were found over 250 images randomly extracted from 25 in vivo pullbacks. Moreover, 3D rendering was compared to angiography, pictures of deployed stents made available by the manufacturers and to conventional 2D imaging corroborating visualization results. Computational time for the visualization of an entire data sets resulted to be ~74 sec. The proposed method allows for the on-line use of 3D IV-OCT during percutaneous coronary interventions, potentially allowing treatments optimization. PMID:23243578
NASA Astrophysics Data System (ADS)
Wagner, Martin G.; Strother, Charles M.; Schafer, Sebastian; Mistretta, Charles A.
2016-03-01
Biplane fluoroscopic imaging is an important tool for minimally invasive procedures for the treatment of cerebrovascular diseases. However, finding a good working angle for the C-arms of the angiography system as well as navigating based on the 2D projection images can be a difficult task. The purpose of this work is to propose a novel 4D reconstruction algorithm for interventional devices from biplane fluoroscopy images and to propose new techniques for a better visualization of the results. The proposed reconstruction methods binarizes the fluoroscopic images using a dedicated noise reduction algorithm for curvilinear structures and a global thresholding approach. A topology preserving thinning algorithm is then applied and a path search algorithm minimizing the curvature of the device is used to extract the 2D device centerlines. Finally, the 3D device path is reconstructed using epipolar geometry. The point correspondences are determined by a monotonic mapping function that minimizes the reconstruction error. The three dimensional reconstruction of the device path allows the rendering of virtual fluoroscopy images from arbitrary angles as well as 3D visualizations like virtual endoscopic views or glass pipe renderings, where the vessel wall is rendered with a semi-transparent material. This work also proposes a combination of different visualization techniques in order to increase the usability and spatial orientation for the user. A combination of synchronized endoscopic and glass pipe views is proposed, where the virtual endoscopic camera position is determined based on the device tip location as well as the previous camera position using a Kalman filter in order to create a smooth path. Additionally, vessel centerlines are displayed and the path to the target is highlighted. Finally, the virtual endoscopic camera position is also visualized in the glass pipe view to further improve the spatial orientation. The proposed techniques could considerably improve the workflow of minimally invasive procedures for the treatment of cerebrovascular diseases.
Infrared and Visual Image Fusion through Fuzzy Measure and Alternating Operators
Bai, Xiangzhi
2015-01-01
The crucial problem of infrared and visual image fusion is how to effectively extract the image features, including the image regions and details and combine these features into the final fusion result to produce a clear fused image. To obtain an effective fusion result with clear image details, an algorithm for infrared and visual image fusion through the fuzzy measure and alternating operators is proposed in this paper. Firstly, the alternating operators constructed using the opening and closing based toggle operator are analyzed. Secondly, two types of the constructed alternating operators are used to extract the multi-scale features of the original infrared and visual images for fusion. Thirdly, the extracted multi-scale features are combined through the fuzzy measure-based weight strategy to form the final fusion features. Finally, the final fusion features are incorporated with the original infrared and visual images using the contrast enlargement strategy. All the experimental results indicate that the proposed algorithm is effective for infrared and visual image fusion. PMID:26184229
Infrared and Visual Image Fusion through Fuzzy Measure and Alternating Operators.
Bai, Xiangzhi
2015-07-15
The crucial problem of infrared and visual image fusion is how to effectively extract the image features, including the image regions and details and combine these features into the final fusion result to produce a clear fused image. To obtain an effective fusion result with clear image details, an algorithm for infrared and visual image fusion through the fuzzy measure and alternating operators is proposed in this paper. Firstly, the alternating operators constructed using the opening and closing based toggle operator are analyzed. Secondly, two types of the constructed alternating operators are used to extract the multi-scale features of the original infrared and visual images for fusion. Thirdly, the extracted multi-scale features are combined through the fuzzy measure-based weight strategy to form the final fusion features. Finally, the final fusion features are incorporated with the original infrared and visual images using the contrast enlargement strategy. All the experimental results indicate that the proposed algorithm is effective for infrared and visual image fusion.
Mazella, Anaïs; Albaret, Jean-Michel; Picard, Delphine
2016-01-01
To fill an important gap in the psychometric assessment of children and adolescents with impaired vision, we designed a new battery of haptic tests, called Haptic-2D, for visually impaired and sighted individuals aged five to 18 years. Unlike existing batteries, ours uses only two-dimensional raised materials that participants explore using active touch. It is composed of 11 haptic tests, measuring scanning skills, tactile discrimination skills, spatial comprehension skills, short-term tactile memory, and comprehension of tactile pictures. We administered this battery to 138 participants, half of whom were sighted (n=69), and half visually impaired (blind, n=16; low vision, n=53). Results indicated a significant main effect of age on haptic scores, but no main effect of vision or Age × Vision interaction effect. Reliability of test items was satisfactory (Cronbach's alpha, α=0.51-0.84). Convergent validity was good, as shown by a significant correlation (age partialled out) between total haptic scores and scores on the B101 test (rp=0.51, n=47). Discriminant validity was also satisfactory, as attested by a lower but still significant partial correlation between total haptic scores and the raw score on the verbal WISC (rp=0.43, n=62). Finally, test-retest reliability was good (rs=0.93, n=12; interval of one to two months). This new psychometric tool should prove useful to practitioners working with young people with impaired vision. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Gargallo, Ana; Arines, Justo
2014-08-01
We have adapted low cost webcams to the slit lamps objectives with the aim of improving contact lens fitting practice. With this solution we obtain good quality pictures and videos, we also recorded videos of eye examination, evaluation routines of contact lens fitting, and the final practice exam of our students. In addition, the video system increases the interactions between students because they could see what their colleagues are doing and take conscious of their mistakes, helping and correcting each others. We think that the proposed system is a low cost solution for supporting the training in contact lens fitting practice.
Tolerability of continuous subcutaneous octreotide used in combination with other drugs.
Mercadante, S
1995-01-01
Continuous subcutaneous infusion of octreotide combined with other drugs has proved to be useful in some circumstances in palliative care setting when theoral route is no longer available. Forty-four patients were administered octreotide alone or in combination with other drugs in the same syringe driver for symptom control in advanced cancer patients. Good tolerability and compatibility were observed without visual drug precipitation for a period of 48 hours at room temperature, the standard clinical situation in patients' homes. Such a combination of drugs administered by the subcutaneous route makes possible the adequate control of symptoms in the final days of life.
An Improved Text Localization Method for Natural Scene Images
NASA Astrophysics Data System (ADS)
Jiang, Mengdi; Cheng, Jianghua; Chen, Minghui; Ku, Xishu
2018-01-01
In order to extract text information effectively from natural scene image with complex background, multi-orientation perspective and multilingual languages, we present a new method based on the improved Stroke Feature Transform (SWT). Firstly, The Maximally Stable Extremal Region (MSER) method is used to detect text candidate regions. Secondly, the SWT algorithm is used in the candidate regions, which can improve the edge detection compared with tradition SWT method. Finally, the Frequency-tuned (FT) visual saliency is introduced to remove non-text candidate regions. The experiment results show that, the method can achieve good robustness for complex background with multi-orientation perspective, various characters and font sizes.
Turbulent structures in cylindrical density currents in a rotating frame of reference
NASA Astrophysics Data System (ADS)
Salinas, Jorge S.; Cantero, Mariano I.; Dari, Enzo A.; Bonometti, Thomas
2018-06-01
Gravity currents are flows generated by the action of gravity on fluids with different densities. In some geophysical applications, modeling such flows makes it necessary to account for rotating effects, modifying the dynamics of the flow. While previous works on rotating stratified flows focused on currents of large Coriolis number, the present work focuses on flows with small Coriolis numbers (i.e. moderate-to-large Rossby numbers). In this work, cylindrical rotating gravity currents are investigated by means of highly resolved simulations. A brief analysis of the mean flow evolution to the final state is presented to provide a complete picture of the flow dynamics. The numerical results, showing the well-known oscillatory behavior of the flow (inertial waves) and a final state lens shape (geostrophic adjustment), are in good agreement with experimental observations and theoretical models. The turbulent structures in the flow are visualized and described using, among others, a stereoscopic visualization and videos as supplementary material. In particular, the structure of the lobes and clefts at the front of the current is presented in association to local turbulent structures. In rotating gravity currents, the vortices observed at the lobes front are not of hairpin type but are rather of Kelvin-Helmholtz type.
Bernheim, Diane; Rouberol, Frederic; Palombi, Karine; Albrieux, Magali; Romanet, Jean-Paul; Chiquet, Christophe
2013-01-01
To compare the anatomical and functional results of primary rhegmatogenous retinal detachment in highly myopic phakic or pseudophakic eyes. This prospective 2-center study included 191 consecutive eyes (151 phakic and 40 pseudophakic eyes) from a prospective cohort of 835 patients (IRB #5891, between 2004 and 2008). Baseline and follow-up data were systematically recorded at presentation, 1 month, and 6 months or more after surgery. On final examination, two groups were considered based on the need for one or more surgeries to achieve retinal reapplication. End points were primary reattachment rate at the 6-month visit, final anatomical success rate, postoperative visual acuity, and intraoperative and postoperative complications. Pseudophakic eyes differed from phakic eyes in age (60.8 ± 10.4 vs. 49.9 ± 12.3, P < 0.001), smaller pupil dilation (8.0 ± 1.5 vs. 8.5 ± 1.2 mm, P = 0.02), fewer retinal tears seen preoperatively (1.5 ± 1.6 vs. 2.2 ± 2.2, P = 0.06), more frequent use of pars plana vitrectomy (80% vs. 28.5%, P < 0.001), and higher single reattachment rate (92.5% vs. 80.7%). Visual acuity was greater than or equal to 20/40 in 54% of cases with single retinal detachment surgery and 44% of cases with multiple surgeries. Multiple logistic regression analysis showed that only 3 independent variables were significantly predictive of good final visual acuity (20/40): initial visual acuity (<20/400, odds ratio = 0.19; 95% confidence interval, 0.07-0.51; P = 0.002), axial length (odds ratio = 0.57; 95% confidence interval, 0.44-0.75, P < 0.001), and pars plana vitrectomy (odds ratio = 0.33; 95% confidence interval, 0.15-0.71, P = 0.004). This prospective study showed similar baseline retinal detachment characteristics of high myopic phakic or pseudophakic eyes, suggesting that high myopia was the main pathogenic factor in both groups. Although high myopic eye presents anatomical characteristics that could favor surgical morbidity, these recent prospective data show that high myopic eyes exhibit functional and anatomical prognosis close to that described in emmetropic eyes.
Visual and Auditory Memory: Relationships to Reading Achievement.
ERIC Educational Resources Information Center
Bruning, Roger H.; And Others
1978-01-01
Good and poor readers' visual and auditory memory were tested. No group differences existed for single mode presentation in recognition frequency or latency. With multimodal presentation, good readers had faster latencies. Dual coding and self-terminating memory search hypotheses were supported. Implications for the reading process and reading…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, M Pauline
2007-06-30
The VisPort visualization portal is an experiment in providing Web-based access to visualization functionality from any place and at any time. VisPort adopts a service-oriented architecture to encapsulate visualization functionality and to support remote access. Users employ browser-based client applications to choose data and services, set parameters, and launch visualization jobs. Visualization products typically images or movies are viewed in the user's standard Web browser. VisPort emphasizes visualization solutions customized for specific application communities. Finally, VisPort relies heavily on XML, and introduces the notion of visualization informatics - the formalization and specialization of information related to the process and productsmore » of visualization.« less
Techniques of Final Preseal Visual Inspection
NASA Technical Reports Server (NTRS)
Anstead, R. J.
1975-01-01
A dissertation is given on the final preseal visual inspection of microcircuit devices to detect manufacturing defects and reduce failure rates in service. The processes employed in fabricating monolithic integrated circuits and hybrid microcircuits, various failure mechanisms resulting from deficiencies in those processes, and the rudiments of performing final inspection are outlined.
To what extent do Gestalt grouping principles influence tactile perception?
Gallace, Alberto; Spence, Charles
2011-07-01
Since their formulation by the Gestalt movement more than a century ago, the principles of perceptual grouping have primarily been investigated in the visual modality and, to a lesser extent, in the auditory modality. The present review addresses the question of whether the same grouping principles also affect the perception of tactile stimuli. Although, to date, only a few studies have explicitly investigated the existence of Gestalt grouping principles in the tactile modality, we argue that many more studies have indirectly provided evidence relevant to this topic. Reviewing this body of research, we argue that similar principles to those reported previously in visual and auditory studies also govern the perceptual grouping of tactile stimuli. In particular, we highlight evidence showing that the principles of proximity, similarity, common fate, good continuation, and closure affect tactile perception in both unimodal and crossmodal settings. We also highlight that the grouping of tactile stimuli is often affected by visual and auditory information that happen to be presented simultaneously. Finally, we discuss the theoretical and applied benefits that might pertain to the further study of Gestalt principles operating in both unisensory and multisensory tactile perception.
[Application of Ocular Trauma Score in Mechanical Ocular Injury in Forensic Medicine].
Xiang, Jian; Guo, Zhao-ming; Wang, Xu; Yu, Li-li; Liu, Hui
2015-10-01
To evaluate the application value for the prognosis of mechanical ocular injury cases using ocular trauma score (OTS). Four hundred and eleven cases of mechanical ocular trauma were retrospectively reviewed. Of the 449 eyes, there were 317 closed globe injury and 132 open globe injury. OTS variables included numerical values as initial visual acuity, rupture, endophthalmitis, perforat- ing or penetrating injury, retinal detachment and relative afferent pupillary block. The differences be- tween the distribution of the final visual acuity and the probability of standard final visual acuity were compared to analyze the correlation between OTS category and final visual acuity. The different types of ocular trauma were compared. Compared with the distribution of final visual acuity in standard OTS score, the ratio in OTS-3 category was statistically different in present study, and no differences were found in other categories. Final visual acuity showed a great linear correlation with OTS category (r = 0.71) and total score (r = 0.73). Compared with closed globe injury, open globe injury was generally associated with lower total score and poorer prognosis. Rupture injury had poorer prognosis compared with penetrating injury. The use of OTS for the patients with ocular trauma can provide re- liable information for the evaluation of prognosis in forensic medicine.
van Delft, Sanne; Goedhart, Annelijn; Spigt, Mark; van Pinxteren, Bart; de Wit, Niek; Hopstaken, Rogier
2016-01-01
Objective Point-of-care testing (POCT) urinalysis might reduce errors in (subjective) reading, registration and communication of test results, and might also improve diagnostic outcome and optimise patient management. Evidence is lacking. In the present study, we have studied the analytical performance of automated urinalysis and visual urinalysis compared with a reference standard in routine general practice. Setting The study was performed in six general practitioner (GP) group practices in the Netherlands. Automated urinalysis was compared with visual urinalysis in these practices. Reference testing was performed in a primary care laboratory (Saltro, Utrecht, The Netherlands). Primary and secondary outcome measures Analytical performance of automated and visual urinalysis compared with the reference laboratory method was the primary outcome measure, analysed by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and Cohen's κ coefficient for agreement. Secondary outcome measure was the user-friendliness of the POCT analyser. Results Automated urinalysis by experienced and routinely trained practice assistants in general practice performs as good as visual urinalysis for nitrite, leucocytes and erythrocytes. Agreement for nitrite is high for automated and visual urinalysis. κ's are 0.824 and 0.803 (ranked as very good and good, respectively). Agreement with the central laboratory reference standard for automated and visual urinalysis for leucocytes is rather poor (0.256 for POCT and 0.197 for visual, respectively, ranked as fair and poor). κ's for erythrocytes are higher: 0.517 (automated) and 0.416 (visual), both ranked as moderate. The Urisys 1100 analyser was easy to use and considered to be not prone to flaws. Conclusions Automated urinalysis performed as good as traditional visual urinalysis on reading of nitrite, leucocytes and erythrocytes in routine general practice. Implementation of automated urinalysis in general practice is justified as automation is expected to reduce human errors in patient identification and transcribing of results. PMID:27503860
van Delft, Sanne; Goedhart, Annelijn; Spigt, Mark; van Pinxteren, Bart; de Wit, Niek; Hopstaken, Rogier
2016-08-08
Point-of-care testing (POCT) urinalysis might reduce errors in (subjective) reading, registration and communication of test results, and might also improve diagnostic outcome and optimise patient management. Evidence is lacking. In the present study, we have studied the analytical performance of automated urinalysis and visual urinalysis compared with a reference standard in routine general practice. The study was performed in six general practitioner (GP) group practices in the Netherlands. Automated urinalysis was compared with visual urinalysis in these practices. Reference testing was performed in a primary care laboratory (Saltro, Utrecht, The Netherlands). Analytical performance of automated and visual urinalysis compared with the reference laboratory method was the primary outcome measure, analysed by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and Cohen's κ coefficient for agreement. Secondary outcome measure was the user-friendliness of the POCT analyser. Automated urinalysis by experienced and routinely trained practice assistants in general practice performs as good as visual urinalysis for nitrite, leucocytes and erythrocytes. Agreement for nitrite is high for automated and visual urinalysis. κ's are 0.824 and 0.803 (ranked as very good and good, respectively). Agreement with the central laboratory reference standard for automated and visual urinalysis for leucocytes is rather poor (0.256 for POCT and 0.197 for visual, respectively, ranked as fair and poor). κ's for erythrocytes are higher: 0.517 (automated) and 0.416 (visual), both ranked as moderate. The Urisys 1100 analyser was easy to use and considered to be not prone to flaws. Automated urinalysis performed as good as traditional visual urinalysis on reading of nitrite, leucocytes and erythrocytes in routine general practice. Implementation of automated urinalysis in general practice is justified as automation is expected to reduce human errors in patient identification and transcribing of results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Smythe, Tracey; Wainwright, Andrew; Foster, Allen; Lavy, Christopher
2017-01-01
Congenital talipes equino-varus (CTEV), also known as clubfoot, is one of the most common congenital musculoskeletal malformations. Despite this, considerable variation exists in the measurement of deformity correction and outcome evaluation. This study aims to determine the criteria for successful clubfoot correction using the Ponseti technique in low resource settings through Africa. Using the Delphi method, 18 experienced clubfoot practitioners and trainers from ten countries in Africa ranked the importance of 22 criteria to define an 'acceptable or good clubfoot correction' at the end of bracing with the Ponseti technique. A 10cm visual analogue scale was used. They repeated the rating with the results of the mean scores and standard deviation of the first test provided. The consistency among trainers was determined with the intra-class correlation coefficient (ICC). From the original 22 criteria, ten criteria with a mean score >7 and SD <2 were identified and were rated through a second Delphi round by 17 different clubfoot treatment trainers from 11 countries in Africa. The final definition consisted of all statements that achieved strong agreement, a mean score of >9 and SD<1.5. The consensus definition of a successfully treated clubfoot includes: (1) a plantigrade foot, (2) the ability to wear a normal shoe, (3) no pain, and (4) the parent is satisfied. Participants demonstrated good consistency in rating these final criteria (ICC 0.88; 0.74,0.97). The consistency of Ponseti technique trainers from Africa in rating criteria for a successful outcome of clubfoot management was good. The consensus definition includes basic physical assessment, footwear use, pain and parent satisfaction.
Kim, Yoon Kyung; Sung, Yon Mi; Cho, So Hyun; Park, Young Nam; Choi, Hye-Young
2014-12-01
Coronary artery calcification (CAC) is frequently detected on low-dose CT (LDCT) of the thorax. Concurrent assessment of CAC and lung cancer screening using LDCT is beneficial in terms of cost and radiation dose reduction. The aim of our study was to evaluate the reliability of visual ranking of positive CAC on LDCT compared to Agatston score (AS) on electrocardiogram (ECG)-gated calcium scoring CT. We studied 576 patients who were consecutively registered for health screening and undergoing both LDCT and ECG-gated calcium scoring CT. We excluded subjects with an AS of zero. The final study cohort included 117 patients with CAC (97 men; mean age, 53.4 ± 8.5). AS was used as the gold standard (mean score 166.0; range 0.4-3,719.3). Two board-certified radiologists and two radiology residents participated in an observer performance study. Visual ranking of CAC was performed according to four categories (1-10, 11-100, 101-400, and 401 or higher) for coronary artery disease risk stratification. Weighted kappa statistics were used to measure the degree of reliability on visual ranking of CAC on LDCT. The degree of reliability on visual ranking of CAC on LDCT compared to ECG-gated calcium scoring CT was excellent for board-certified radiologists and good for radiology residents. A high degree of association was observed with 71.6% of visual rankings in the same category as the Agatston category and 98.9% varying by no more than one category. Visual ranking of positive CAC on LDCT is reliable for predicting AS rank categorization.
Santos, Ana R; Costa, Miguel Â; Schwartz, Christian; Alves, Dalila; Figueira, João; Silva, Rufino; Cunha-Vaz, Jose G
2018-06-01
To identify baseline optical coherence tomography morphologic characteristics predicting the visual response to anti-vascular endothelial growth factor therapy in diabetic macular edema. Sixty-seven patients with diabetic macular edema completed a prospective, observational study (NCT01947881-CHARTRES). All patients received monthly intravitreal injections of Lucentis for 3 months followed by PRN treatment and underwent best-corrected visual acuity measurements and spectral domain optical coherence tomography at Baseline, Months 1, 2, 3, and 6. Visual treatment response was characterized as good (≥10 letters), moderate (5-10 letters), and poor (<5 or letters loss). Spectral domain optical coherence tomography images were graded before and after treatment by a certified Reading Center. One month after loading dose, 26 patients (38.80%) were identified as good responders, 19 (28.35%) as Moderate and 22 (32.83%) as poor responders. There were no significant best-corrected visual acuity and central retinal thickness differences at baseline (P = 0.176; P = 0.573, respectively). Ellipsoid zone disruption and disorganization of retinal inner layers were good predictors for treatment response, representing a significant risk for poor visual recovery to anti-vascular endothelial growth factor therapy (odds ratio = 10.96; P < 0.001 for ellipsoid zone disruption and odds ratio = 7.05; P = 0.034 for disorganization of retinal inner layers). Damage of ellipsoid zone, higher values of disorganization of retinal inner layers, and central retinal thickness decrease are good predictors of best-corrected visual acuity response to anti-vascular endothelial growth factor therapy.
Removing Visual Bias in Filament Identification: A New Goodness-of-fit Measure
NASA Astrophysics Data System (ADS)
Green, C.-E.; Cunningham, M. R.; Dawson, J. R.; Jones, P. A.; Novak, G.; Fissel, L. M.
2017-05-01
Different combinations of input parameters to filament identification algorithms, such as disperse and filfinder, produce numerous different output skeletons. The skeletons are a one-pixel-wide representation of the filamentary structure in the original input image. However, these output skeletons may not necessarily be a good representation of that structure. Furthermore, a given skeleton may not be as good of a representation as another. Previously, there has been no mathematical “goodness-of-fit” measure to compare output skeletons to the input image. Thus far this has been assessed visually, introducing visual bias. We propose the application of the mean structural similarity index (MSSIM) as a mathematical goodness-of-fit measure. We describe the use of the MSSIM to find the output skeletons that are the most mathematically similar to the original input image (the optimum, or “best,” skeletons) for a given algorithm, and independently of the algorithm. This measure makes possible systematic parameter studies, aimed at finding the subset of input parameter values returning optimum skeletons. It can also be applied to the output of non-skeleton-based filament identification algorithms, such as the Hessian matrix method. The MSSIM removes the need to visually examine thousands of output skeletons, and eliminates the visual bias, subjectivity, and limited reproducibility inherent in that process, representing a major improvement upon existing techniques. Importantly, it also allows further automation in the post-processing of output skeletons, which is crucial in this era of “big data.”
Experimental investigations into visual and electronic tooth color measurement.
Ratzmann, Anja; Treichel, Anja; Langforth, Gabriele; Gedrange, Tomasz; Welk, Alexander
2011-04-01
The present study aimed to examine the validity of the visual color assessment and an electronic tooth color measurement system by means of Shade Inspector™ in comparison with a gold standard. Additionally, reproducibility of electronic measurements was demonstrated by means of two reference systems. Ceramic specimens of two thicknesses (h=1.6 mm, h=2.6 mm) were used. Three experienced dental technicians using the VITAPAN Classical(®) color scale carried out all visual tests. Validity of the visual assessment and the electronic measurements was confirmed separately for both thicknesses by means of lightness and hue of the VITAPAN Classical(®) color scale. Reproducibility of electronic measurements was confirmed by means of the VITAPAN Classical(®) and 3D-Master(®). The 3D-Master(®) data were calculated according to lightness, hue and chroma. Intraclass correlation coefficient (ICC) was used in assessing validity/reproducibility for lightness and chroma, Kappa statistics were used for hue. A level ≥0.75 was pre-established for ICC and ≥0.60 for the Kappa index. RESULTS OF VISUAL COLOR ASSESSMENT: Validity for lightness was good for both thicknesses; agreement rates for hue were inconsistent. ELECTRONIC MEASUREMENT: Validity for lightness was fair to good, hue values were below 0.60. Reproducibility of lightness was good to very good for both reference systems. Hue values (VITAPAN Classical(®)) for 1.6 mm test specimens were upside, for 2.6 mm below 0.60, Kappa values for 3D-Master(®) were ≥0.60 for all measurements, reproducibility of chroma was very good. Validity was better for visual than for electronic color assessment. Reproducibility of the electronic device by means of the Shade Inspector™ was given for the VITAPAN Classical(®) and 3D-Master(®) systems.
Auditory, Visual, and Auditory-Visual Perception of Vowels by Hearing-Impaired Children.
ERIC Educational Resources Information Center
Hack, Zarita Caplan; Erber, Norman P.
1982-01-01
Vowels were presented through auditory, visual, and auditory-visual modalities to 18 hearing impaired children (12 to 15 years old) having good, intermediate, and poor auditory word recognition skills. All the groups had difficulty with acoustic information and visual information alone. The first two groups had only moderate difficulty identifying…
Diagnosing cerebral visual impairment in children with good visual acuity.
van Genderen, Maria; Dekker, Marjoke; Pilon, Florine; Bals, Irmgard
2012-06-01
To identify elements that could facilitate the diagnosis of cerebral visual impairment (CVI) in children with good visual acuity in the general ophthalmic clinic. We retrospectively investigated the clinical characteristics of 30 children with good visual acuity and CVI and compared them with those of 23 children who were referred with a suspicion of CVI, but proved to have a different diagnosis. Clinical characteristics included medical history, MRI findings, visual acuity, crowding ratio (CR), visual field assessment, and the results of ophthalmologic and orthoptic examination. We also evaluated the additional value of a short CVI questionnaire. Eighty-three percent of the children with an abnormal medical history (mainly prematurity and perinatal hypoxia) had CVI, in contrast with none of the children with a normal medical history. Cerebral palsy, visual field defects, and partial optic atrophy only occurred in the CVI group. 41% of the children with CVI had a CR ≥2.0, which may be related to dorsal stream dysfunction. All children with CVI, but also 91% of the children without CVI gave ≥3 affirmative answers on the CVI questionnaire. An abnormal pre- or perinatal medical history is the most important risk factor for CVI in children, and therefore in deciding which children should be referred for further multidisciplinary assessment. Additional symptoms of cerebral damage, i.e., cerebral palsy, visual field defects, partial optic atrophy, and a CR ≥2 may support the diagnosis. CVI questionnaires should not be used for screening purposes as they yield too many false positives.
Studying visual attention using the multiple object tracking paradigm: A tutorial review.
Meyerhoff, Hauke S; Papenmeier, Frank; Huff, Markus
2017-07-01
Human observers are capable of tracking multiple objects among identical distractors based only on their spatiotemporal information. Since the first report of this ability in the seminal work of Pylyshyn and Storm (1988, Spatial Vision, 3, 179-197), multiple object tracking has attracted many researchers. A reason for this is that it is commonly argued that the attentional processes studied with the multiple object paradigm apparently match the attentional processing during real-world tasks such as driving or team sports. We argue that multiple object tracking provides a good mean to study the broader topic of continuous and dynamic visual attention. Indeed, several (partially contradicting) theories of attentive tracking have been proposed within the almost 30 years since its first report, and a large body of research has been conducted to test these theories. With regard to the richness and diversity of this literature, the aim of this tutorial review is to provide researchers who are new in the field of multiple object tracking with an overview over the multiple object tracking paradigm, its basic manipulations, as well as links to other paradigms investigating visual attention and working memory. Further, we aim at reviewing current theories of tracking as well as their empirical evidence. Finally, we review the state of the art in the most prominent research fields of multiple object tracking and how this research has helped to understand visual attention in dynamic settings.
Social Vision: Functional Forecasting and the Integration of Compound Social Cues
Adams, Reginald B.; Kveraga, Kestutis
2017-01-01
For decades the study of social perception was largely compartmentalized by type of social cue: race, gender, emotion, eye gaze, body language, facial expression etc. This was partly due to good scientific practice (e.g., controlling for extraneous variability), and partly due to assumptions that each type of social cue was functionally distinct from others. Herein, we present a functional forecast approach to understanding compound social cue processing that emphasizes the importance of shared social affordances across various cues (see too Adams, Franklin, Nelson, & Stevenson, 2010; Adams & Nelson, 2011; Weisbuch & Adams, 2012). We review the traditional theories of emotion and face processing that argued for dissociable and noninteracting pathways (e.g., for specific emotional expressions, gaze, identity cues), as well as more recent evidence for combinatorial processing of social cues. We argue here that early, and presumably reflexive, visual integration of such cues is necessary for adaptive behavioral responding to others. In support of this claim, we review contemporary work that reveals a flexible visual system, one that readily incorporates meaningful contextual influences in even nonsocial visual processing, thereby establishing the functional and neuroanatomical bases necessary for compound social cue integration. Finally, we explicate three likely mechanisms driving such integration. Together, this work implicates a role for cognitive penetrability in visual perceptual abilities that have often been (and in some cases still are) ascribed to direct encapsulated perceptual processes. PMID:29242738
Methods for Multiloop Identification of Visual and Neuromuscular Pilot Responses.
Olivari, Mario; Nieuwenhuizen, Frank M; Venrooij, Joost; Bülthoff, Heinrich H; Pollini, Lorenzo
2015-12-01
In this paper, identification methods are proposed to estimate the neuromuscular and visual responses of a multiloop pilot model. A conventional and widely used technique for simultaneous identification of the neuromuscular and visual systems makes use of cross-spectral density estimates. This paper shows that this technique requires a specific noninterference hypothesis, often implicitly assumed, that may be difficult to meet during actual experimental designs. A mathematical justification of the necessity of the noninterference hypothesis is given. Furthermore, two methods are proposed that do not have the same limitations. The first method is based on autoregressive models with exogenous inputs, whereas the second one combines cross-spectral estimators with interpolation in the frequency domain. The two identification methods are validated by offline simulations and contrasted to the classic method. The results reveal that the classic method fails when the noninterference hypothesis is not fulfilled; on the contrary, the two proposed techniques give reliable estimates. Finally, the three identification methods are applied to experimental data from a closed-loop control task with pilots. The two proposed techniques give comparable estimates, different from those obtained by the classic method. The differences match those found with the simulations. Thus, the two identification methods provide a good alternative to the classic method and make it possible to simultaneously estimate human's neuromuscular and visual responses in cases where the classic method fails.
Zhong, Xianhua; Li, Dan; Du, Wei; Yan, Mengqiu; Wang, You; Huo, Danqun; Hou, Changjun
2018-06-01
Volatile organic compounds (VOCs) in breath can be used as biomarkers to identify early stages of lung cancer. Herein, we report a disposable colorimetric array that has been constructed from diverse chemo-responsive colorants. Distinguishable difference maps were plotted within 4 min for specifically targeted VOCs. Through the consideration of various chemical interactions with VOCs, the arrays successfully discriminate between 20 different volatile organic compounds in breath that are related to lung cancer. VOCs were identified either with the visualized difference maps or through pattern recognition with an accuracy of at least 90%. No uncertainties or errors were observed in the hierarchical cluster analysis (HCA). Finally, good reproducibility and stability of the array was achieved against changes in humidity. Generally, this work provides fundamental support for construction of simple and rapid VOC sensors. More importantly, this approach provides a hypothesis-free array method for breath testing via VOC profiling. Therefore, this small, rapid, non-invasive, inexpensive, and visualized sensor array is a powerful and promising tool for early screening of lung cancer. Graphical abstract A disposable colorimetric array has been developed with broadly chemo-responsive dyes to incorporate various chemical interactions, through which the arrays successfully discriminate 20 VOCs that are related to lung cancer via difference maps alone or chemometrics within 4 min. The hydrophobic porous matrix provides good stability against changes in humidity.
[Multifocal phakic intraocular lens implant to correct presbyopia].
Baikoff, G; Matach, G; Fontaine, A; Ferraz, C; Spera, C
2005-03-01
Presbyopic surgery is considered as the new frontier in refractive surgery. Different solutions are proposed: myopization of one eye, insertion of an accommodative crystalline lens, scleral surgery, the effects of which are still unknown, and finally multifocal phakic implants. We therefore decided to undertake a prospective study under the Huriet law to determine its efficacy and specify the conditions required for an anterior chamber multifocal phakic implant. Fifty-five eyes of 33 patients received an anterior chamber foldable multifocal phakic implant. Twenty-one females and 12 males underwent surgery. Initial refraction was between -5D and +5D. The implant's single addition was +2.50. Recuperating a distant uncorrected visual acuity of 0.6 or better and near uncorrected vision of Parinaud 3 or better can be considered a very good postoperative result. Average follow-up was 42.6+/-18 weeks. Mean postoperative refraction was -0.12+/-0.51 D. Mean postoperative uncorrected visual acuity was 0.78+/-0.20. Postoperative uncorrected visual acuity was Parinaud 2.3+/-0.6. Eighty-four percent of eyes operated on recuperated 0.6 or better without correction and Parinaud 3 or better without correction. Lenses in four eyes were explanted for different reasons, essentially optical, and no severe anatomical complications were observed. Placing an anterior chamber multifocal phakic implant to correct presbyopia is an effective technique with good predictability and has the advantage of being reversible in case of intolerance, optical parasite effects or undesired complications. Considering the particularity of this surgery, it is imperative to respect very strict inclusion criteria: anterior chamber depth equal to or above 3.1 mm, open angle, endothelial cell count equal to or above 2000 cells/mm2, absence of an incipient cataract or the slightest evidence of macular alteration.
Kerkhof, M; Hagenbeek, R E; van der Kallen, B F W; Lycklama À Nijeholt, G J; Dirven, L; Taphoorn, M J B; Vos, M J
2016-10-01
Conventional magnetic resonance imaging (MRI) has limited value for differentiation of true tumor progression and pseudoprogression in treated glioblastoma multiforme (GBM). Perfusion weighted imaging (PWI) may be helpful in the differentiation of these two phenomena. Here interobserver variability in routine radiological evaluation of GBM patients is assessed using MRI, including PWI. Three experienced neuroradiologists evaluated MR scans of 28 GBM patients during temozolomide chemoradiotherapy at three time points: preoperative (MR1) and postoperative (MR2) MR scan and the follow-up MR scan after three cycles of adjuvant temozolomide (MR3). Tumor size was measured both on T1 post-contrast and T2 weighted images according to the Response Assessment in Neuro-Oncology criteria. PW images of MR3 were evaluated by visual inspection of relative cerebral blood volume (rCBV) color maps and by quantitative rCBV measurements of enhancing areas with highest rCBV. Image interpretability of PW images was also scored. Finally, the neuroradiologists gave a conclusion on tumor status, based on the interpretation of both T1 and T2 weighted images (MR1, MR2 and MR3) in combination with PWI (MR3). Interobserver agreement on visual interpretation of rCBV maps was good (κ = 0.63) but poor on quantitative rCBV measurements and on interpretability of perfusion images (intraclass correlation coefficient 0.37 and κ = 0.23, respectively). Interobserver agreement on the overall conclusion of tumor status was moderate (κ = 0.48). Interobserver agreement on the visual interpretation of PWI color maps was good. However, overall interpretation of MR scans (using both conventional and PW images) showed considerable interobserver variability. Therefore, caution should be applied when interpreting MRI results during chemoradiation therapy. © 2016 EAN.
ARTIFICIAL LIGHTING FOR MODERN SCHOOLS, A GUIDE FOR ADMINISTRATIVE USE.
ERIC Educational Resources Information Center
REIDA, GEORGE W.; AND OTHERS
THE DEVELOPMENT OF GOOD VISUAL ENVIRONMENT AND ECONOMICALLY FEASIBLE LIGHTING INSTALLATIONS IN SCHOOLS IS DISCUSSED IN THIS GUIDE. EIGHTY PERCENT OF ALL SCHOOL LEARNING IS GAINED THROUGH THE EYES AS ESTIMATED BY THE U.S. OFFICE OF EDUCATION. GOOD SCHOOL LIGHTING IS COMFORTABLE, GLAREFREE AND ADEQUATE FOR THE VISUAL TASK. EYE STRAIN AND UNNECESSARY…
Research of cartographer laser SLAM algorithm
NASA Astrophysics Data System (ADS)
Xu, Bo; Liu, Zhengjun; Fu, Yiran; Zhang, Changsai
2017-11-01
As the indoor is a relatively closed and small space, total station, GPS, close-range photogrammetry technology is difficult to achieve fast and accurate indoor three-dimensional space reconstruction task. LIDAR SLAM technology does not rely on the external environment a priori knowledge, only use their own portable lidar, IMU, odometer and other sensors to establish an independent environment map, a good solution to this problem. This paper analyzes the Google Cartographer laser SLAM algorithm from the point cloud matching and closed loop detection. Finally, the algorithm is presented in the 3D visualization tool RViz from the data acquisition and processing to create the environment map, complete the SLAM technology and realize the process of indoor threedimensional space reconstruction
Visual Acuity Outcomes of the Boston Keratoprosthesis Type 1: Multicenter Study Results.
Rudnisky, Christopher J; Belin, Michael W; Guo, Rong; Ciolino, Joseph B
2016-02-01
To report logarithm of the minimal angle of resolution (logMAR) visual outcomes of the Boston keratoprosthesis type 1. Prospective cohort study. Preoperative, intraoperative, and postoperative parameters of 300 eyes of 300 patients who underwent implantation of a Boston keratoprosthesis type 1 device between January 2003 and July 2008 by 1 of 19 surgeons at 18 medical centers were collected. After an average of 17.1 ± 14.8 months, visual acuity improved significantly (P < .0001) to a mean final value of 0.89 ± 0.64 (20/150). There were also significantly fewer eyes with light perception (6.7%; n = 19; P < .0001), although 3.1% (n = 9) progressed to no light perception. There was no association between age (P = .08), sex (P = .959), operative side (P = .167), or failure (P = .494) and final visual acuity. The median time to achieve 20/200 visual acuity was 1 month (95% confidence interval 1.0-6.0) and it was retained for an average of 47.8 months. Multivariate analysis, controlling for preoperative visual acuity, demonstrated 2 factors associated with final visual outcome: chemical injury was associated with better final vision (P = .007), whereas age-related macular degeneration was associated with poorer vision (P < .0001). The Boston keratoprosthesis type 1 is an effective device for rehabilitation in advanced ocular surface disease, resulting in a significant improvement in visual acuity. Eyes achieved a mean value of 20/150 (0.89 ± 0.64 logMAR units) after 6 months and this was relatively stable thereafter. The best visual prognosis is observed in chemical injury eyes, whereas the worst prognosis is in aniridia, although the latter has limited visual potential. Copyright © 2016 Elsevier Inc. All rights reserved.
Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Kachooei, Amir Reza
2015-01-01
We aimed to validate a cross-culturally adapted version of the Persian Michigan Hand Outcomes Questionnaire (MHOQ). We followed the Beaton's guideline to translate the questionnaire to Persian. We administered the final version to 223 patients among which 79 patients returned 3 days later to respond to the Persian MHOQ for the second time. In the first visit, respondents also filled the Disabilities of the Arm Shoulder and Hand (DASH) and rated the pain based on the Visual Analogue Scale (VAS). Cronbach's alpha for the total MHOQ was 0.79 which showed good internal consistency. Intraclass correlation coefficient (ICC) for the total MHOQ was 0.84 which demonstrated good reliability between test and retest. The absolute correlation coefficient between total MHOQ and the DASH was as high as 0.74. Persian version of the MHOQ proved to be a reliable and valid instrument to be implemented among Persian population with the hand and wrist disorders.
Verveer, P. J; Gemkow, M. J; Jovin, T. M
1999-01-01
We have compared different image restoration approaches for fluorescence microscopy. The most widely used algorithms were classified with a Bayesian theory according to the assumed noise model and the type of regularization imposed. We considered both Gaussian and Poisson models for the noise in combination with Tikhonov regularization, entropy regularization, Good's roughness and without regularization (maximum likelihood estimation). Simulations of fluorescence confocal imaging were used to examine the different noise models and regularization approaches using the mean squared error criterion. The assumption of a Gaussian noise model yielded only slightly higher errors than the Poisson model. Good's roughness was the best choice for the regularization. Furthermore, we compared simulated confocal and wide-field data. In general, restored confocal data are superior to restored wide-field data, but given sufficient higher signal level for the wide-field data the restoration result may rival confocal data in quality. Finally, a visual comparison of experimental confocal and wide-field data is presented.
Dynamics of a class of vortex rings. Ph.D. Thesis - Stanford Univ.
NASA Technical Reports Server (NTRS)
Shariff, Karim; Leonard, Anthony; Ferziger, Joel H.
1989-01-01
The contour dynamics method is extended to vortex rings with vorticity varying linearly from the symmetry axis. An elliptic core model is also developed to explain some of the basic physics. Passage and collisions of two identical rings are studied focusing on core deformation, sound generation and stirring of fluid elements. With respect to core deformation, not only the strain rate but how rapidly it varies is important and accounts for greater susceptibility to vortex tearing than in two dimensions. For slow strain, as a passage interaction is completed and the strain relaxes, the cores return to their original shape while permanent deformations remain for rapidly varying strain. For collisions, if the strain changes slowly the core shapes migrate through a known family of two-dimensional steady vortex pairs up to the limiting member of the family. Thereafter energy conservation does not allow the cores to maintain a constant shape. For rapidly varying strain, core deformation is severe and a head-tail structure in good agreement with experiments is formed. With respect to sound generation, good agreement with the measured acoustic signal for colliding rings is obtained and a feature previously thought to be due to viscous effects is shown to be an effect of inviscid core deformation alone. For passage interactions, a component of high frequency is present. Evidence for the importance of this noise source in jet noise spectra is provided. Finally, processes of fluid engulfment and rejection for an unsteady vortex ring are studied using the stable and unstable manifolds. The unstable manifold shows excellent agreement with flow visualization experiments for leapfrogging rings suggesting that it may be a good tool for numerical flow visualization in other time periodic flows.
Potential future impacts on visual air quality for Class I areas
Gurule Nochumson; Mona J. Wecksung
1979-01-01
Visual air quality is most sensitive to degradation by air pollution in areas with good visibility. The protection of visual air quality in mandatory Class I Federal areas has been declared a national goal by Congress. Impacts on visual air quality are calculated for 154 Class I areas where visual air quality is considered an important value. These impacts are...
Murthy, Gudlavalleti V S; John, Neena; Shamanna, Bindiganavale R; Pant, Hira B
2012-01-01
Background: In the final push toward the elimination of avoidable blindness, cataract occupies a position of eminence for the success of the Right to Sight initiative. Aims: Review existing situation and assess what monitoring indicators may be useful to chart progress towards attaining the goals of Vision 2020. Settings and Design: Review of published papers from low and middle income countries since 2000. Materials and Methods: Published population-based data on prevalence of cataract blindness/visual impairment were accessed and prevalence of cataract blindness/visual impairment computed, where not reported. Data on prevalence of cataract blindness, cataract surgical coverage at different visual acuity cut offs, surgical outcomes, and prevalence of cataract surgery were analyzed. Scatter plots were used to look at relationships of some variables, with Human Development Index (HDI) rank. Available data on Cataract Surgical Rate (CSR) was plotted against prevalence of cataract surgery reported from surveys. Results: Worse HDI Ranks were associated with higher prevalence of cataract blindness. Most studies showed that a significant proportion of the blind were covered by surgery, while a fifth showed that a significant proportion, were operated before they went blind. A good visual outcome after surgery was positively correlated with higher surgical coverage. CSR was positively correlated with cataract surgical coverage. Conclusions: Cataract surgical coverage is increasing in most countries at vision <3/60 and visual outcomes after cataract surgery are improving. Establishing population-based surveillance of cataract surgical need and performance is a strong monitoring tool and will help program planners immensely. PMID:22944756
Schlickum, Marcus; Hedman, Leif; Felländer-Tsai, Li
2016-02-21
To investigate whether surgical simulation performance and previous video gaming experience would correlate with higher motivation to further train a specific simulator task and whether visual-spatial ability would rank higher in importance to surgical performance than the above. It was also examined whether or not motivation would correlate with a preference to choose a surgical specialty in the future and if simulator training would increase the interest in choosing that same work field. Motivation and general interest in surgery was measured pre- and post-training in 30 medical students at Karolinska Institutet who were tested in a laparoscopic surgical simulator in parallel with measurement of visual-spatial ability and self-estimated video gaming experience. Correlations between simulator performance metrics, visual-spatial ability and motivation were statistically analyzed using regression analysis. A good result in the first simulator trial correlated with higher self-determination index (r =-0.46, p=0.05) in male students. Visual-spatial ability was the most important underlying factor followed by intrinsic motivation score and finally video gaming experience (p=0.02, p=0.05, p=0.11) regarding simulator performance in male students. Simulator training increased interest in surgery when studying all subjects (p=0.01), male subjects (p=0.02) as well as subjects with low video gaming experience (p=0.02). This preliminary study highlights individual differences regarding the effect of simulator training on motivation that can be taken into account when designing simulator training curricula, although the sample size is quite small and findings should be interpreted carefully.
Processing Of Visual Information In Primate Brains
NASA Technical Reports Server (NTRS)
Anderson, Charles H.; Van Essen, David C.
1991-01-01
Report reviews and analyzes information-processing strategies and pathways in primate retina and visual cortex. Of interest both in biological fields and in such related computational fields as artificial neural networks. Focuses on data from macaque, which has superb visual system similar to that of humans. Authors stress concept of "good engineering" in understanding visual system.
Serial sectioning for examination of photoreceptor cell architecture by focused ion beam technology
Mustafi, Debarshi; Avishai, Amir; Avishai, Nanthawan; Engel, Andreas; Heuer, Arthur; Palczewski, Krzysztof
2011-01-01
Structurally deciphering complex neural networks requires technology with sufficient resolution to allow visualization of single cells and their intimate surrounding connections. Scanning electron microscopy (SEM), coupled with serial ion ablation (SIA) technology, presents a new avenue to study these networks. SIA allows ion ablation to remove nanometer sections of tissue for SEM imaging, resulting in serial section data collection for three-dimensional reconstruction. Here we highlight a method for preparing retinal tissues for imaging of photoreceptors by SIA-SEM technology. We show that this technique can be used to visualize whole rod photoreceptors and the internal disc elements from wild-type (wt) mice. The distance parameters of the discs and photoreceptors are in good agreement with previous work with other methods. Moreover, we show that large planes of retinal tissue can be imaged at high resolution to display the packing of normal rods. Finally, SIA-SEM imaging of retinal tissue from a mouse model (Nrl−/−) with phenotypic changes akin to the human disease enhanced S-cone syndrome (ESCS) revealed a structural profile of overall photoreceptor ultrastructure and internal elements that accompany this disease. Overall, this work presents a new method to study photoreceptor cells at high structural resolution that has a broad applicability to the visual neuroscience field. PMID:21439323
Scene-Aware Adaptive Updating for Visual Tracking via Correlation Filters
Zhang, Sirou; Qiao, Xiaoya
2017-01-01
In recent years, visual object tracking has been widely used in military guidance, human-computer interaction, road traffic, scene monitoring and many other fields. The tracking algorithms based on correlation filters have shown good performance in terms of accuracy and tracking speed. However, their performance is not satisfactory in scenes with scale variation, deformation, and occlusion. In this paper, we propose a scene-aware adaptive updating mechanism for visual tracking via a kernel correlation filter (KCF). First, a low complexity scale estimation method is presented, in which the corresponding weight in five scales is employed to determine the final target scale. Then, the adaptive updating mechanism is presented based on the scene-classification. We classify the video scenes as four categories by video content analysis. According to the target scene, we exploit the adaptive updating mechanism to update the kernel correlation filter to improve the robustness of the tracker, especially in scenes with scale variation, deformation, and occlusion. We evaluate our tracker on the CVPR2013 benchmark. The experimental results obtained with the proposed algorithm are improved by 33.3%, 15%, 6%, 21.9% and 19.8% compared to those of the KCF tracker on the scene with scale variation, partial or long-time large-area occlusion, deformation, fast motion and out-of-view. PMID:29140311
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-14
..., direct final rule concerning household goods consumer protection. The direct final rule amended the... No. FMCSA-2012-0119] RIN 2126-AB52 Transportation of Household Goods in Interstate Commerce; Consumer Protection Regulations AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Direct final...
NASA Astrophysics Data System (ADS)
Hinsby, Klaus; Broers, Hans Peter
2014-05-01
The EU Water Framework and Groundwater Directives stipulate that EU member states (MS) should ensure good groundwater chemical and quantitative by 2015. For the assessment of good chemical status the MS have to establish Natural Background Levels (NBLs) and Threshold Values (TVs) for groundwater bodies at risk and compare current concentration levels to these. In addition the MS shall ensure trend reversals in cases where contaminants or water levels show critical increasing or decreasing trends. The EU MS have to demonstrate that the quantitative and chemical status of its groundwater bodies does not put drinking water, ecosystems or other legitimate uses at risk. Easy on-line access to relevant visualizations of groundwater quality and quantity data of e.g. nitrate, chloride, arsenic and water tables in Europe's major aquifer types compiled from national databases would be of great importance for managers, authorities and scientists conducting risk and status assessments. The Water Resources Expert Group of the EuroGeoSurveys propose to develop Pan-European interactive on-line digital maps and visualizations of concentrations levels and trends, as well as calculated natural background levels and threshold values for the most important aquifer types of Europe mainly derived based on principles established in the former EU project "BRIDGE" - Background cRiteria for the IDentification of Groundwater Thresholds. Further, we propose to develop Pan-European digital and dynamic maps and cross sections in close collaboration with ecologists, which delineate dependent or associated terrestrial and aquatic ecosystems across Europe where groundwater quantity and quality plays a significant role in sustaining good ecological status of the ecosystem, and where the water resources and ecosystems are most vulnerable to climate change. Finally, integrated water resources management requires integrated consideration of both deep and shallow groundwater and surface water issues and interaction. It is therefore proposed to map regions of Europe that use coupled groundwater-surface water models in integrated water resources and river basin management. In the presentation we will show selected examples of data visualizations of importance to integrated water resources and river basin management and the implementation of the Water Framework Directive.
Combined influence of visual scene and body tilt on arm pointing movements: gravity matters!
Scotto Di Cesare, Cécile; Sarlegna, Fabrice R; Bourdin, Christophe; Mestre, Daniel R; Bringoux, Lionel
2014-01-01
Performing accurate actions such as goal-directed arm movements requires taking into account visual and body orientation cues to localize the target in space and produce appropriate reaching motor commands. We experimentally tilted the body and/or the visual scene to investigate how visual and body orientation cues are combined for the control of unseen arm movements. Subjects were asked to point toward a visual target using an upward movement during slow body and/or visual scene tilts. When the scene was tilted, final pointing errors varied as a function of the direction of the scene tilt (forward or backward). Actual forward body tilt resulted in systematic target undershoots, suggesting that the brain may have overcompensated for the biomechanical movement facilitation arising from body tilt. Combined body and visual scene tilts also affected final pointing errors according to the orientation of the visual scene. The data were further analysed using either a body-centered or a gravity-centered reference frame to encode visual scene orientation with simple additive models (i.e., 'combined' tilts equal to the sum of 'single' tilts). We found that the body-centered model could account only for some of the data regarding kinematic parameters and final errors. In contrast, the gravity-centered modeling in which the body and visual scene orientations were referred to vertical could explain all of these data. Therefore, our findings suggest that the brain uses gravity, thanks to its invariant properties, as a reference for the combination of visual and non-visual cues.
Combined Influence of Visual Scene and Body Tilt on Arm Pointing Movements: Gravity Matters!
Scotto Di Cesare, Cécile; Sarlegna, Fabrice R.; Bourdin, Christophe; Mestre, Daniel R.; Bringoux, Lionel
2014-01-01
Performing accurate actions such as goal-directed arm movements requires taking into account visual and body orientation cues to localize the target in space and produce appropriate reaching motor commands. We experimentally tilted the body and/or the visual scene to investigate how visual and body orientation cues are combined for the control of unseen arm movements. Subjects were asked to point toward a visual target using an upward movement during slow body and/or visual scene tilts. When the scene was tilted, final pointing errors varied as a function of the direction of the scene tilt (forward or backward). Actual forward body tilt resulted in systematic target undershoots, suggesting that the brain may have overcompensated for the biomechanical movement facilitation arising from body tilt. Combined body and visual scene tilts also affected final pointing errors according to the orientation of the visual scene. The data were further analysed using either a body-centered or a gravity-centered reference frame to encode visual scene orientation with simple additive models (i.e., ‘combined’ tilts equal to the sum of ‘single’ tilts). We found that the body-centered model could account only for some of the data regarding kinematic parameters and final errors. In contrast, the gravity-centered modeling in which the body and visual scene orientations were referred to vertical could explain all of these data. Therefore, our findings suggest that the brain uses gravity, thanks to its invariant properties, as a reference for the combination of visual and non-visual cues. PMID:24925371
The development and validation of the Visual Analogue Self-Esteem Scale (VASES).
Brumfitt, S M; Sheeran, P
1999-11-01
To develop a visual analogue measure of self-esteem and test its psychometric properties. Two correlational studies involving samples of university students and aphasic speakers. Two hundred and forty-three university students completed multiple measures of self-esteem, depression and anxiety as well as measures of transitory mood and social desirability (Study 1). Two samples of aphasic speakers (N = 14 and N = 20) completed the Visual Analogue Self-Esteem Scale (VASES), the Rosenberg (1965) self-esteem scale and measures of depression and anxiety. (Study 2). Study 1 found evidence of good internal and test-retest reliability, construct validity and convergent and discriminant validity for a 10-item VASES. Study 2 demonstrated good internal reliability among aphasic speakers. The VASES is a short and easy to administer measure of self-esteem that possesses good psychometric properties.
The Impact of Accelerated Promotion Rates on Drill Sergeant Performance
2011-01-01
land navigation, communication (voice/visual), NBC protection). I have good knowledge of most Warrior tasks; I have sufficient skills to handle...but seldom reach out on my own initiative. I communicate and work well with others regardless of background; I encourage attitudes of tolerance and...most of the Warrior tasks (e.g., land navigation, communication (voice/visual), NBC protection). I have good knowledge of most Warrior tasks; I
Robust Stereo Visual Odometry Using Improved RANSAC-Based Methods for Mobile Robot Localization
Liu, Yanqing; Gu, Yuzhang; Li, Jiamao; Zhang, Xiaolin
2017-01-01
In this paper, we present a novel approach for stereo visual odometry with robust motion estimation that is faster and more accurate than standard RANSAC (Random Sample Consensus). Our method makes improvements in RANSAC in three aspects: first, the hypotheses are preferentially generated by sampling the input feature points on the order of ages and similarities of the features; second, the evaluation of hypotheses is performed based on the SPRT (Sequential Probability Ratio Test) that makes bad hypotheses discarded very fast without verifying all the data points; third, we aggregate the three best hypotheses to get the final estimation instead of only selecting the best hypothesis. The first two aspects improve the speed of RANSAC by generating good hypotheses and discarding bad hypotheses in advance, respectively. The last aspect improves the accuracy of motion estimation. Our method was evaluated in the KITTI (Karlsruhe Institute of Technology and Toyota Technological Institute) and the New Tsukuba dataset. Experimental results show that the proposed method achieves better results for both speed and accuracy than RANSAC. PMID:29027935
Rhatigan, Maedbh; McElnea, Elizabeth; Murtagh, Patrick; Stephenson, Kirk; Harris, Elaine; Connell, Paul; Keegan, David
2018-01-01
To report anatomic and visual outcomes following silicone oil removal in a cohort of patients with complex retinal detachment, to determine association between duration of tamponade and outcomes and to compare patients with oil removed and those with oil in situ in terms of demographic, surgical and visual factors. We reported a four years retrospective case series of 143 patients with complex retinal detachments who underwent intraocular silicone oil tamponade. Analysis between anatomic and visual outcomes, baseline demographics, duration of tamponade and number of surgical procedures were carried out using Fisher's exact test and unpaired two-tailed t -test. One hundred and six patients (76.2%) had undergone silicone oil removal at the time of review with 96 patients (90.6%) showing retinal reattachment following oil removal. Duration of tamponade was not associated with final reattachment rate or with a deterioration in best corrected visual acuity (BCVA). Patients with oil removed had a significantly better baseline and final BCVA compared to those under oil tamponade ( P =0.0001, <0.0001 respectively). Anatomic and visual outcomes in this cohort are in keeping with those reported in the literature. Favorable outcomes were seen with oil removal but duration of oil tamponade does not affect final attachment rate with modern surgical techniques and should be managed on a case by case basis.
Zhu, X; Ye, H; He, W; Yang, J; Dai, J; Lu, Y
2017-01-01
Purpose To explore the objective functional visual outcomes of cataract surgery in patients with good preoperative visual acuity. Methods We enrolled 130 cataract patients whose best-corrected visual acuity (BCVA) was 20/40 or better preoperatively. Objective visual functions were evaluated with a KR-1W analyzer before and at 1 month after cataract surgery. Results The nuclear (N), cortical (C), and N+C groups had very high preoperative ocular and internal total high-order aberrations (HOAs), coma, and abnormal spherical aberrations. At 1 month after cataract surgery, in addition to the remarkable increase of both uncorrected visual acuity and BCVA, both ocular and internal HOAs in the three groups decreased significantly after cataract surgery (all P<0.05). Point spread function and modulation transfer functions were also improved significantly in these patients (all P<0.05). Conclusions The objective functional vision of patients with 20/40 or better preoperative BCVA improved significantly after cataract surgery. This finding shows that the arbitrary threshold of BCVA worse than 20/40 in China cannot always be used to determine who will benefit from cataract surgery. PMID:27858933
ERIC Educational Resources Information Center
Hart, Verna; Ferrell, Kay
Twenty-four congenitally visually handicapped infants, aged 6-24 months, participated in a study to determine (1) those stimuli best able to elicit visual attention, (2) the stability of visual acuity over time, and (3) the effects of binaural sensory aids on both visual attention and visual acuity. Ss were dichotomized into visually handicapped…
Infant Visual Recognition Memory
ERIC Educational Resources Information Center
Rose, Susan A.; Feldman, Judith F.; Jankowski, Jeffery J.
2004-01-01
Visual recognition memory is a robust form of memory that is evident from early infancy, shows pronounced developmental change, and is influenced by many of the same factors that affect adult memory; it is surprisingly resistant to decay and interference. Infant visual recognition memory shows (a) modest reliability, (b) good discriminant…
ERIC Educational Resources Information Center
Chen, Zhongzhou; Gladding, Gary
2014-01-01
Visual representations play a critical role in teaching physics. However, since we do not have a satisfactory understanding of how visual perception impacts the construction of abstract knowledge, most visual representations used in instructions are either created based on existing conventions or designed according to the instructor's intuition,…
ERIC Educational Resources Information Center
Hunter, Zoe R.; Brysbaert, Marc
2008-01-01
Traditional neuropsychology employs visual half-field (VHF) experiments to assess cerebral language dominance. This approach is based on the assumption that left cerebral dominance for language leads to faster and more accurate recognition of words in the right visual half-field (RVF) than in the left visual half-field (LVF) during tachistoscopic…
Collinearity Impairs Local Element Visual Search
ERIC Educational Resources Information Center
Jingling, Li; Tseng, Chia-Huei
2013-01-01
In visual searches, stimuli following the law of good continuity attract attention to the global structure and receive attentional priority. Also, targets that have unique features are of high feature contrast and capture attention in visual search. We report on a salient global structure combined with a high orientation contrast to the…
School Starters' Vision--An Educational Approach
ERIC Educational Resources Information Center
Wilhelmsen, Gunvor B
2016-01-01
Although good visual capacity is essential for children's learning, we have limited understanding of the various visual functions among school starters. In order to extend this knowledge, a small-scale study was undertaken involving 24 preschool children age 5-6 years who completed a test battery originally designed for visual impairment…
Shastri, Surendra S; Dinshaw, Ketayun; Amin, Geetanjali; Goswami, Smriti; Patil, Sharmila; Chinoy, Roshini; Kane, S; Kelkar, Rohini; Muwonge, Richard; Mahé, Cédric; Ajit, Dulhan; Sankaranarayanan, R
2005-03-01
Naked eye visual inspection with acetic acid (VIA), magnified VIA (VIAM), visual inspection with Lugol's iodine (VILI), cytology and human papillomavirus (HPV) testing were evaluated as screening methods for the detection of high-grade squamous intraepithelial lesions (HSIL) of the uterine cervix in a cross-sectional study in Mumbai, India. Cytology, HPV testing, VIA, VIAM and VILI were carried out concurrently for 4039 women aged 30-65 years. All women were investigated with colposcopy and biopsies were taken from 939 women who had colposcopic abnormalities. The reference standard for final disease status was histology or negative colposcopy. The presence of HSIL was confirmed in 57 women (1.4%). The test characteristics for each method were calculated using standard formulae. The sensitivities of cytology, HPV testing, VIA, VIAM and VILI were 57.4%, 62.0%, 59.7%, 64.9%, and 75.4%, respectively (differences were not statistically significant). The specificities were 98.6%, 93.5%, 88.4%, 86.3%, and 84.3%, respectively. Adding a visual test to cytology or HPV testing in parallel combination resulted in a substantial increase in sensitivity, with a moderate decrease in specificity. The parallel combination of VILI and HPV testing resulted in a sensitivity of 92.0% and a specificity of 79.9%. As a single test, cytology had the best balance of sensitivity and specificity. Visual tests are promising in low-resource settings, such as India. The use of both VIA and VILI may be considered where good quality cytology or HPV testing are not feasible. The sensitivity of cytology and HPV testing increased significantly when combined with VIA or VILI.
Hedman, Leif; Felländer-Tsai, Li
2016-01-01
Objectives To investigate whether surgical simulation performance and previous video gaming experience would correlate with higher motivation to further train a specific simulator task and whether visual-spatial ability would rank higher in importance to surgical performance than the above. It was also examined whether or not motivation would correlate with a preference to choose a surgical specialty in the future and if simulator training would increase the interest in choosing that same work field. Methods Motivation and general interest in surgery was measured pre- and post-training in 30 medical students at Karolinska Institutet who were tested in a laparoscopic surgical simulator in parallel with measurement of visual-spatial ability and self-estimated video gaming experience. Correlations between simulator performance metrics, visual-spatial ability and motivation were statistically analyzed using regression analysis. Results A good result in the first simulator trial correlated with higher self-determination index (r =-0.46, p=0.05) in male students. Visual-spatial ability was the most important underlying factor followed by intrinsic motivation score and finally video gaming experience (p=0.02, p=0.05, p=0.11) regarding simulator performance in male students. Simulator training increased interest in surgery when studying all subjects (p=0.01), male subjects (p=0.02) as well as subjects with low video gaming experience (p=0.02). Conclusions This preliminary study highlights individual differences regarding the effect of simulator training on motivation that can be taken into account when designing simulator training curricula, although the sample size is quite small and findings should be interpreted carefully. PMID:26897701
Regression Models for Identifying Noise Sources in Magnetic Resonance Images
Zhu, Hongtu; Li, Yimei; Ibrahim, Joseph G.; Shi, Xiaoyan; An, Hongyu; Chen, Yashen; Gao, Wei; Lin, Weili; Rowe, Daniel B.; Peterson, Bradley S.
2009-01-01
Stochastic noise, susceptibility artifacts, magnetic field and radiofrequency inhomogeneities, and other noise components in magnetic resonance images (MRIs) can introduce serious bias into any measurements made with those images. We formally introduce three regression models including a Rician regression model and two associated normal models to characterize stochastic noise in various magnetic resonance imaging modalities, including diffusion-weighted imaging (DWI) and functional MRI (fMRI). Estimation algorithms are introduced to maximize the likelihood function of the three regression models. We also develop a diagnostic procedure for systematically exploring MR images to identify noise components other than simple stochastic noise, and to detect discrepancies between the fitted regression models and MRI data. The diagnostic procedure includes goodness-of-fit statistics, measures of influence, and tools for graphical display. The goodness-of-fit statistics can assess the key assumptions of the three regression models, whereas measures of influence can isolate outliers caused by certain noise components, including motion artifacts. The tools for graphical display permit graphical visualization of the values for the goodness-of-fit statistic and influence measures. Finally, we conduct simulation studies to evaluate performance of these methods, and we analyze a real dataset to illustrate how our diagnostic procedure localizes subtle image artifacts by detecting intravoxel variability that is not captured by the regression models. PMID:19890478
Rabin, Alon; Portnoy, Sigal; Kozol, Zvi
2016-11-01
Rabin, A, Portnoy, S, and Kozol, Z. The association between visual assessment of quality of movement and three-dimensional analysis of pelvis, hip, and knee kinematics during a lateral step down test. J Strength Cond Res 30(11): 3204-3211, 2016-Altered movement patterns including contralateral pelvic drop, increased hip adduction, knee abduction, and external rotation have been previously implicated in several lower extremity pathologies. Although various methods exist for assessing movement patterns, real-time visual observation is the most readily available method. The purpose of this study was to determine whether differing visual ratings of trunk, pelvis, and knee alignment, as well as overall quality of movement, are associated with differences in 3-dimensional trunk, pelvis, hip, or knee kinematics during a lateral step down test. Trunk, pelvis, and knee alignment of 30 healthy participants performing the lateral step down were visually rated as "good" or "faulty" based on previously established criteria. An additional categorization of overall quality of movement as either good or moderate was performed based on the aggregate score of each individual rating criterion. Three-dimensional motion analysis of trunk, pelvis, hip, and knee kinematics was simultaneously performed. A faulty pelvis alignment displayed a greater peak contralateral pelvic drop (effect size [ES], 1.65; p < 0.01) and a greater peak hip adduction (ES: 1.04, p = 0.01) compared with participants with a good pelvis alignment. Participants with a faulty knee alignment displayed greater peak knee external rotation compared with participants with a good knee alignment (ES, 0.78; p = 0.02). Participants with an overall moderate quality of movement displayed increased peak contralateral pelvic drop (ES, 1.07; p = 0.01) and peak knee external rotation (ES, 0.72; p = 0.04) compared with those with an overall good quality of movement. Visual rating of quality of movement during a lateral step down test, as performed by an experienced physical therapist, is associated with differences in several kinematics previously implicated in various pathologies.
ERIC Educational Resources Information Center
Moore, Sheri Bortner
The final report summarizes beginnings as well as accomplishments of a program designed to develop materials for parents and teachers working with visually impaired children at the birth-24 month developmental level. The focus of the materials was to help parents and teachers prevent and remediate developmental lags associated with visual…
Occlusion therapy in amblyopia: an experience from Hong Kong.
Tang, Emily W H; Li, Brian C Y; Yeung, Ian Y L; Li, Kenneth K W
2014-02-01
OBJECTIVES. To review the results of patching for amblyopia management in Hong Kong. DESIGN. Retrospective case series. SETTING. Regional hospital, Hong Kong. PATIENTS. Records of all patients attending Paediatric Ophthalmology Clinic at United Christian Hospital, Hong Kong from 1 January 2009 to 31 March 2009 were retrospectively reviewed. Records of all children who underwent patching for amblyopia in the study period were evaluated. RESULTS. The mean age of 50 children (50 eyes) was 4 (standard deviation, 1; range, 2-7) years and mean pretreatment visual acuity was 0.35 (0.15; 0.02-0.63) [~20/60]. The values for mean, standard deviation, and range of treatment duration were 27, 16, 4-67 months respectively, and corresponding values for prescribed patching per day were 4, 1, 2-8 hours. The mean, standard deviation, and range of visual acuity at final post-treatment assessment were 0.66, 0.16, 0.1-1.0 (~20/30), respectively. The overall success rate (ie final visual acuity >0.7 or 20/30) was 62%. Children with moderate amblyopia (20/40-20/80) and severe amblyopia (20/100-20/400) had success rates of 74% and 55%, respectively. The mean visual acuity improvements for moderate and severely amblyopic children were 2.3 lines and 5.8 lines, respectively. The mean, standard deviation, and range of patching prescriptions for moderate and severely amblyopic children were 5, 1, 2-7 hours and 5, 1, 3-6 hours, respectively. Recurrence ensued in 7% of the children with moderate amblyopia and 46% of those with severe amblyopia. Reported compliance was good (>75% of the time) in 68% of the children. CONCLUSION. Occlusion therapy is the mainstay of treatment in Hong Kong. The overall success rate was comparable to that achieved in the Amblyopia Treatment Study. Recurrence was more common in patients with severe amblyopia, for whom maintenance therapy may reduce the risk of recurrence. The duration of treatment was much longer in our locality than in western countries. Reported compliance was suspicious possibly due to traditional cultural contexts. It is important to emphasise compliance to all parents.
Comparing different stimulus configurations for population receptive field mapping in human fMRI
Alvarez, Ivan; de Haas, Benjamin; Clark, Chris A.; Rees, Geraint; Schwarzkopf, D. Samuel
2015-01-01
Population receptive field (pRF) mapping is a widely used approach to measuring aggregate human visual receptive field properties by recording non-invasive signals using functional MRI. Despite growing interest, no study to date has systematically investigated the effects of different stimulus configurations on pRF estimates from human visual cortex. Here we compared the effects of three different stimulus configurations on a model-based approach to pRF estimation: size-invariant bars and eccentricity-scaled bars defined in Cartesian coordinates and traveling along the cardinal axes, and a novel simultaneous “wedge and ring” stimulus defined in polar coordinates, systematically covering polar and eccentricity axes. We found that the presence or absence of eccentricity scaling had a significant effect on goodness of fit and pRF size estimates. Further, variability in pRF size estimates was directly influenced by stimulus configuration, particularly for higher visual areas including V5/MT+. Finally, we compared eccentricity estimation between phase-encoded and model-based pRF approaches. We observed a tendency for more peripheral eccentricity estimates using phase-encoded methods, independent of stimulus size. We conclude that both eccentricity scaling and polar rather than Cartesian stimulus configuration are important considerations for optimal experimental design in pRF mapping. While all stimulus configurations produce adequate estimates, simultaneous wedge and ring stimulation produced higher fit reliability, with a significant advantage in reduced acquisition time. PMID:25750620
A case of Churg-Strauss syndrome and central retinal artery occlusion with good visual recovery.
Kamata, Yuki; Hashizume, Kouhei; Kaneko, Muneyoshi; Kurosaka, Daijiro
2013-04-01
Here we report a case of Churg-Strauss syndrome (CSS) and central retinal artery occlusion (CRAO), with good visual recovery. A 58-year-old Japanese man with CSS experienced acute painless loss of vision in his right eye. CRAO was diagnosed by fundoscopic findings (retinal whitening with a cherry-red spot). Steroid pulse therapy (methylprednisolone at 1 g daily for 3 days) followed by combined treatment with prednisolone (30 mg/day) and cyclophosphamide (150 mg/day) was administered; his visual acuity recovered to 20/30 in 1 month, and no recurrence has occurred for 1 year. Steroid pulse therapy may be effective for CRAO in CSS patients.
NASA Technical Reports Server (NTRS)
Sahasrabudhe, Vineet; Melkers, Edgar; Faynberg, Alexander; Blanken, Chris L.
2003-01-01
The UH-60 BLACK HAWK was designed in the 1970s, when the US Army primarily operated during the day in good visual conditions. Subsequently, the introduction of night-vision goggles increased the BLACK HAWK'S mission effectiveness, but the accident rate also increased. The increased accident rate is strongly tied to increased pilot workload as a result of a degradation in visual cues. Over twenty years of research in helicopter flight control and handling qualities has shown that these degraded handling qualities can be recovered by modifying the response type of the helicopter in low speed flight. Sikorsky Aircraft Corporation initiated a project under the National Rotorcraft Technology Center (NRTC) to develop modern flight control laws while utilizing the existing partial authority Stability Augmentation System (SAS) of the BLACK HAWK. This effort resulted in a set of Modernized Control Laws (MCLAWS) that incorporate rate command and attitude command response types. Sikorsky and the US Army Aeroflightdynamics Directorate (AFDD) conducted a piloted simulation on the NASA-Ames Vertical h4otion Simulator, to assess potential handling qualities and to reduce the risk of subsequent implementation and flight test of these modern control laws on AFDD's EH-60L helicopter. The simulation showed that Attitude Command Attitude Hold control laws in pitch and roll improve handling qualities in the low speed flight regime. These improvements are consistent across a range of mission task elements and for both good and degraded visual environments. The MCLAWS perform better than the baseline UH-60A control laws in the presence of wind and turbulence. Finally, while the improved handling qualities in the pitch and roll axis allow the pilot to pay more attention to the vertical axis and hence altitude performance also improves, it is clear from pilot comments and altitude excursions that the addition of an Altitude Hold function would further reduce workload and improve overall handling qualities of the aircraft.
The development of visual speech perception in Mandarin Chinese-speaking children.
Chen, Liang; Lei, Jianghua
2017-01-01
The present study aimed to investigate the development of visual speech perception in Chinese-speaking children. Children aged 7, 13 and 16 were asked to visually identify both consonant and vowel sounds in Chinese as quickly and accurately as possible. Results revealed (1) an increase in accuracy of visual speech perception between ages 7 and 13 after which the accuracy rate either stagnates or drops; and (2) a U-shaped development pattern in speed of perception with peak performance in 13-year olds. Results also showed that across all age groups, the overall levels of accuracy rose, whereas the response times fell for simplex finals, complex finals and initials. These findings suggest that (1) visual speech perception in Chinese is a developmental process that is acquired over time and is still fine-tuned well into late adolescence; (2) factors other than cross-linguistic differences in phonological complexity and degrees of reliance on visual information are involved in development of visual speech perception.
Management of varicella zoster virus retinitis in AIDS
Moorthy, R.; Weinberg, D.; Teich, S.; Berger, B.; Minturn, J.; Kumar, S.; Rao, N.; Fowell, S.; Loose, I.; Jampol, L.
1997-01-01
AIMS/BACKGROUND—Varicella zoster virus retinitis (VZVR) in patients with AIDS, also called progressive outer retinal necrosis (PORN), is a necrotising viral retinitis which has resulted in blindness in most patients. The purposes of this study were to investigate the clinical course and visual outcome, and to determine if the choice of a systemic antiviral therapy affected the final visual outcome in patients with VZVR and AIDS. METHODS—A review of the clinical records of 20 patients with VZVR from six centres was performed. Analysis of the clinical characteristics at presentation was performed. Kruskall-Wallis non-parametric one way analysis of variance (KWAOV) of the final visual acuities of patients treated with acyclovir, ganciclovir, foscarnet, or a combination of foscarnet and ganciclovir was carried out. RESULTS—Median follow up was 6 months (range 1.3-26 months). On presentation, 14 of 20 patients (70%) had bilateral disease, and 75% (15 of 20 patients) had previous or concurrent extraocular manifestations of VZV infection. Median initial and final visual acuities were 20/40 and hand movements, respectively. Of 39 eyes involved, 19 eyes (49%) were no light perception at last follow up; 27 eyes (69%) developed rhegmatogenous retinal detachments. Patients treated with combination ganciclovir and foscarnet therapy or ganciclovir alone had significantly better final visual acuity than those treated with either acyclovir or foscarnet (KWAOV: p = 0.0051). CONCLUSIONS—This study represents the second largest series, the longest follow up, and the first analysis of visual outcomes based on medical therapy for AIDS patients with VZVR. Aggressive medical treatment with appropriate systemic antivirals may improve long term visual outcome in patients with VZVR. Acyclovir appears to be relatively ineffective in treating this disease. PMID:9135381
NASA Astrophysics Data System (ADS)
Chen, Zhongzhou; Gladding, Gary
2014-06-01
Visual representations play a critical role in teaching physics. However, since we do not have a satisfactory understanding of how visual perception impacts the construction of abstract knowledge, most visual representations used in instructions are either created based on existing conventions or designed according to the instructor's intuition, which leads to a significant variance in their effectiveness. In this paper we propose a cognitive mechanism based on grounded cognition, suggesting that visual perception affects understanding by activating "perceptual symbols": the basic cognitive unit used by the brain to construct a concept. A good visual representation activates perceptual symbols that are essential for the construction of the represented concept, whereas a bad representation does the opposite. As a proof of concept, we conducted a clinical experiment in which participants received three different versions of a multimedia tutorial teaching the integral expression of electric potential. The three versions were only different by the details of the visual representation design, only one of which contained perceptual features that activate perceptual symbols essential for constructing the idea of "accumulation." On a following post-test, participants receiving this version of tutorial significantly outperformed those who received the other two versions of tutorials designed to mimic conventional visual representations used in classrooms.
SmartAdP: Visual Analytics of Large-scale Taxi Trajectories for Selecting Billboard Locations.
Liu, Dongyu; Weng, Di; Li, Yuhong; Bao, Jie; Zheng, Yu; Qu, Huamin; Wu, Yingcai
2017-01-01
The problem of formulating solutions immediately and comparing them rapidly for billboard placements has plagued advertising planners for a long time, owing to the lack of efficient tools for in-depth analyses to make informed decisions. In this study, we attempt to employ visual analytics that combines the state-of-the-art mining and visualization techniques to tackle this problem using large-scale GPS trajectory data. In particular, we present SmartAdP, an interactive visual analytics system that deals with the two major challenges including finding good solutions in a huge solution space and comparing the solutions in a visual and intuitive manner. An interactive framework that integrates a novel visualization-driven data mining model enables advertising planners to effectively and efficiently formulate good candidate solutions. In addition, we propose a set of coupled visualizations: a solution view with metaphor-based glyphs to visualize the correlation between different solutions; a location view to display billboard locations in a compact manner; and a ranking view to present multi-typed rankings of the solutions. This system has been demonstrated using case studies with a real-world dataset and domain-expert interviews. Our approach can be adapted for other location selection problems such as selecting locations of retail stores or restaurants using trajectory data.
Information consumerism on the World Wide Web: implications for dermatologists and patients.
Travers, Robin L
2002-09-01
The World Wide Web (WWW) is continuing to grow exponentially both in terms of numbers of users and numbers of web pages. There is a trend toward the increasing use of the WWW for medical educational purposes, both among physicians and patients alike. The multimedia capabilities of this evolving medium are particularly relevant to visual medical specialties such as dermatology. The origins of information consumerism on the WWW are examined, and the public health issues surrounding dermatologic information and misinformation, and how consumers navigate through the WWW are reviewed. The economic realities of medical information as a "capital good," and the impact this has on dermatologic information sources on the WWW are also discussed.Finally, strategies for guiding consumers and ourselves toward credible medical information sources on the WWW are outlined.
Optimizing the Compressive Strength of Strain-Hardenable Stretch-Formed Microtruss Architectures
NASA Astrophysics Data System (ADS)
Yu, Bosco; Abu Samk, Khaled; Hibbard, Glenn D.
2015-05-01
The mechanical performance of stretch-formed microtrusses is determined by both the internal strut architecture and the accumulated plastic strain during fabrication. The current study addresses the question of optimization, by taking into consideration the interdependency between fabrication path, material properties and architecture. Low carbon steel (AISI1006) and aluminum (AA3003) material systems were investigated experimentally, with good agreement between measured values and the analytical model. The compressive performance of the microtrusses was then optimized on a minimum weight basis under design constraints such as fixed starting sheet thickness and final microtruss height by satisfying the Karush-Kuhn-Tucker condition. The optimization results were summarized as carpet plots in order to meaningfully visualize the interdependency between architecture, microstructural state, and mechanical performance, enabling material and processing path selection.
Experimental characterization of wingtip vortices in the near field using smoke flow visualizations
NASA Astrophysics Data System (ADS)
Serrano-Aguilera, J. J.; García-Ortiz, J. Hermenegildo; Gallardo-Claros, A.; Parras, L.; del Pino, C.
2016-08-01
In order to predict the axial development of the wingtip vortices strength, an accurate theoretical model is required. Several experimental techniques have been used to that end, e.g. PIV or hot-wire anemometry, but they imply a significant cost and effort. For this reason, we have performed experiments using the smoke-wire technique to visualize smoke streaks in six planes perpendicular to the main stream flow direction. Using this visualization technique, we obtained quantitative information regarding the vortex velocity field by means of Batchelor's model for two chord-based Reynolds numbers, Re_c=3.33× 10^4 and 10^5. Therefore, this theoretical vortex model has been introduced in the integration of ordinary differential equations which describe the temporal evolution of streak lines as function of two parameters: the swirl number, S, and the virtual axial origin, overline{z_0}. We have applied two different procedures to minimize the distance between experimental and theoretical flow patterns: individual curve fitting at six different control planes in the streamwise direction and the global curve fitting which corresponds to all the control planes simultaneously. Both sets of results have been compared with those provided by del Pino et al. (Phys Fluids 23(013):602, 2011b. doi: 10.1063/1.3537791), finding good agreement. Finally, we have observed a weak influence of the Reynolds number on the values S and overline{z_0} at low-to-moderate Re_c. This experimental technique is proposed as a low cost alternative to characterize wingtip vortices based on flow visualizations.
Hafez, Ashraf T; El-Assmy, Ahmed; Dawaba, Mohamed S; Sarhan, Osama; Bazeed, Mahmoud
2005-02-01
We evaluated the long-term results of visual internal urethrotomy for pediatric urethral strictures to evaluate the efficacy and final outcome of this procedure in children and to evaluate the risk factors for stricture recurrence. The computerized surgical records of our hospital were reviewed to identify children who underwent visual internal urethrotomy between 1980 and 2001. Hospital and followup clinical charts were then reviewed. Many variables were analyzed, including age, etiology, length and site of the strictures, and catheter duration. Only patients with a minimum followup of 2 years were included. Regular self-catheterization was not used by any child. A total of 31 patients (mean age 11.2 years, range 2 to 18) were identified. Followup ranged from 2 to 20 years, with a mean of 6.6 years. The most common etiology for stricture formation was failed previous urethroplasty and post instrumentation (35.5% and 32.3%, respectively). The success rate after initial urethrotomy was 35.5% (11 of 31 patients). Mean interval to first recurrence was 26 months. A second urethrotomy improved the success rate of 58.1%. Eight patients required 2 or more urethrotomies, of whom half required open urethroplasty. Among the evaluated variables only stricture length shorter than 1 cm was associated with good results. Visual internal urethrotomy provides a safe first line therapeutic option for pediatric urethral strictures shorter than 1 cm, independent of etiology and location. For patients with more than 1 recurrence or with strictures longer than 1 cm, who are at high risk for recurrence after internal urethrotomy, open urethroplasty remains the treatment of choice.
FuryExplorer: visual-interactive exploration of horse motion capture data
NASA Astrophysics Data System (ADS)
Wilhelm, Nils; Vögele, Anna; Zsoldos, Rebeka; Licka, Theresia; Krüger, Björn; Bernard, Jürgen
2015-01-01
The analysis of equine motion has a long tradition in the past of mankind. Equine biomechanics aims at detecting characteristics of horses indicative of good performance. Especially, veterinary medicine gait analysis plays an important role in diagnostics and in the emerging research of long-term effects of athletic exercises. More recently, the incorporation of motion capture technology contributed to an easier and faster analysis, with a trend from mere observation of horses towards the analysis of multivariate time-oriented data. However, due to the novelty of this topic being raised within an interdisciplinary context, there is yet a lack of visual-interactive interfaces to facilitate time series data analysis and information discourse for the veterinary and biomechanics communities. In this design study, we bring visual analytics technology into the respective domains, which, to our best knowledge, was never approached before. Based on requirements developed in the domain characterization phase, we present a visual-interactive system for the exploration of horse motion data. The system provides multiple views which enable domain experts to explore frequent poses and motions, but also to drill down to interesting subsets, possibly containing unexpected patterns. We show the applicability of the system in two exploratory use cases, one on the comparison of different gait motions, and one on the analysis of lameness recovery. Finally, we present the results of a summative user study conducted in the environment of the domain experts. The overall outcome was a significant improvement in effectiveness and efficiency in the analytical workflow of the domain experts.
Cywinski, Adam; Piwonska-Lobermajer, Anna; Penter, Sandra
2016-08-01
A retrospective analysis of visual function and postoperative complaints in patients after posterior vitrectomy and multifocal Mplus or MplusX intraocular lens implantation. 14 patients (14 eyes) were enrolled in the study. All patients underwent posterior vitrectomy due to underlying retinal pathologies. A combined procedure of phacovitrectomy was performed in some patients, whereas others underwent a separate cataract extraction as a second stage of treatment. The Mplus or MplusX intraocular lenses were implanted in all cases and the postoperative visual function and patient complaints were analysed. Multifocal lens explantation was not necessary in any case. Good uncorrected distance and near visual acuity was achieved in most cases. When implanted prior to vitrectomy, the intraocular lenses did not limit the view into the posterior segment, so precise manipulations within the macula and peripheral retina were feasible. The right choice between Mplus and MplusX minimises the rate of postoperative complaints. Conslusions: The multifocal Mplus and MplusX intraocular lenses offer a good alternative for patients who need posterior vitrectomy and still want to achieve good uncorrected distance and near visual acuity.
Study of Collaborative Management for Transportation Construction Project Based on BIM Technology
NASA Astrophysics Data System (ADS)
Jianhua, Liu; Genchuan, Luo; Daiquan, Liu; Wenlei, Li; Bowen, Feng
2018-03-01
Abstract. Building Information Modeling(BIM) is a building modeling technology based on the relevant information data of the construction project. It is an advanced technology and management concept, which is widely used in the whole life cycle process of planning, design, construction and operation. Based on BIM technology, transportation construction project collaborative management can have better communication through authenticity simulation and architectural visualization and can obtain the basic and real-time information such as project schedule, engineering quality, cost and environmental impact etc. The main services of highway construction management are integrated on the unified BIM platform for collaborative management to realize information intercommunication and exchange, to change the isolated situation of information in the past, and improve the level of information management. The final BIM model is integrated not only for the information management of project and the integration of preliminary documents and design drawings, but also for the automatic generation of completion data and final accounts, which covers the whole life cycle of traffic construction projects and lays a good foundation for smart highway construction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, Robert; Abplanalp, Jennifer M.
2015-03-01
This report presents the results of a study conducted to document the visibility and visual characteristics of the Ivanpah Solar Electric Generating System (ISEGS), a utility-scale solar power tower facility located on land administered by the U.S. Department of the Interior Bureau of Land Management in southern California. Study activities consisted of field observations of the ISEGS facility and comparison of the observations made in the field with the visual contrast assessments and visual simulations in the ISEGS Final Environmental Impact Statement (Final EIS) and supporting documents created prior to ISEGS construction. Field observations of ISEGS were made from 19more » locations within 35 mi (56 km) of the facility in the course of one week in September 2014. The study results established that reflected sunlight from the receivers was the primary source of visual contrast from the operating ISEGS facility. The ISEGS facility was found to be a major source of visual contrast for all observations up to 20 mi (32 km), and was easily visible at 35 mi. Glare from individual heliostats was frequently visible, and often brighter than the reflected light from the receivers. Heliostat glare caused discomfort for one or more viewers at distances up to 20 mi. The ISEGS power blocks were brightly lit at night, and were conspicuous at the observation distance of approximately 6 mi (10 km). The facility is substantially brighter and is seen more clearly in the field than in photographs of the facility or in the prepared simulations, which were based on photographs. The simulations of the ISEGS facility in the Final EIS, which were evaluated as part of this study, sometimes lacked spatial accuracy and realism. The evaluated simulations generally under-represented the actual visual contrast from the project, and some of the contrast ratings in the Final EIS predicted substantially lower levels of visual contrast than were actually observed for the operating facility.« less
Good Food, Bad Food, and White Rice: Understanding Child Feeding Using Visual-Narrative Elicitation.
Wentworth, Chelsea
2017-01-01
Visual-narrative elicitation, a process combining photo elicitation and pile sorting in applied medical anthropology, sheds light on food consumption patterns in urban areas of Vanuatu where childhood malnutrition is a persistent problem. Groups of participants took photographs of the foods they feed their children, and the resources and barriers they encounter in accessing foodstuffs. This revealed how imported and local foods are assigned value as "good" or "bad" foods when contributing to dietary diversity and creating appropriate meals for children, particularly in the context of consuming white rice. The process of gathering and working with photographs illuminated the complex negotiations in which caregivers engaged when making food and nutritional choices for their children. At the nexus of visual and medical anthropology, the visual-narrative elicitation process yielded nuanced, comprehensive understandings of how caregivers value the various foods they feed their children.
Charest, Émilie; Gagné, Marie-Hélène; Goulet, Julie
2017-08-01
This article discusses the development and pretesting of key visual imagery in a promotional campaign developed in Quebec, Canada. This campaign is the media-based component of a broader prevention strategy involving the use of the Triple P program (Sanders, 1999). The purpose was to pretest with parents the preliminary version of a poster that uses the campaign's key visual imagery prior to final production. In total, 26 parents from the regions of Quebec City and Montreal participated in four focus groups. Two general themes emerged from the focus groups: (i) emotions and reactions arising from the key visual imagery; and (ii) comprehension of the message being conveyed. Based on this information, recommendations were made to the marketing agency, which then modified the campaign's key visual imagery and proposed a final layout.
Künstler, E C S; Finke, K; Günther, A; Klingner, C; Witte, O; Bublak, P
2018-01-01
Dual tasking, or the simultaneous execution of two continuous tasks, is frequently associated with a performance decline that can be explained within a capacity sharing framework. In this study, we assessed the effects of a concurrent motor task on the efficiency of visual information uptake based on the 'theory of visual attention' (TVA). TVA provides parameter estimates reflecting distinct components of visual processing capacity: perceptual threshold, visual processing speed, and visual short-term memory (VSTM) storage capacity. Moreover, goodness-of-fit values and bootstrapping estimates were derived to test whether the TVA-model is validly applicable also under dual task conditions, and whether the robustness of parameter estimates is comparable in single- and dual-task conditions. 24 subjects of middle to higher age performed a continuous tapping task, and a visual processing task (whole report of briefly presented letter arrays) under both single- and dual-task conditions. Results suggest a decline of both visual processing capacity and VSTM storage capacity under dual-task conditions, while the perceptual threshold remained unaffected by a concurrent motor task. In addition, goodness-of-fit values and bootstrapping estimates support the notion that participants processed the visual task in a qualitatively comparable, although quantitatively less efficient way under dual-task conditions. The results support a capacity sharing account of motor-cognitive dual tasking and suggest that even performing a relatively simple motor task relies on central attentional capacity that is necessary for efficient visual information uptake.
The sensory strength of voluntary visual imagery predicts visual working memory capacity.
Keogh, Rebecca; Pearson, Joel
2014-10-09
How much we can actively hold in mind is severely limited and differs greatly from one person to the next. Why some individuals have greater capacities than others is largely unknown. Here, we investigated why such large variations in visual working memory (VWM) capacity might occur, by examining the relationship between visual working memory and visual mental imagery. To assess visual working memory capacity participants were required to remember the orientation of a number of Gabor patches and make subsequent judgments about relative changes in orientation. The sensory strength of voluntary imagery was measured using a previously documented binocular rivalry paradigm. Participants with greater imagery strength also had greater visual working memory capacity. However, they were no better on a verbal number working memory task. Introducing a uniform luminous background during the retention interval of the visual working memory task reduced memory capacity, but only for those with strong imagery. Likewise, for the good imagers increasing background luminance during imagery generation reduced its effect on subsequent binocular rivalry. Luminance increases did not affect any of the subgroups on the verbal number working memory task. Together, these results suggest that luminance was disrupting sensory mechanisms common to both visual working memory and imagery, and not a general working memory system. The disruptive selectivity of background luminance suggests that good imagers, unlike moderate or poor imagers, may use imagery as a mnemonic strategy to perform the visual working memory task. © 2014 ARVO.
Self-rated imagery and encoding strategies in visual memory.
Berger, G H; Gaunitz, S C
1979-02-01
The value of self-rated vividness of imagery in predicting performance was investigated, taking into account the mnemonic strategies utilized among subjects performing a visual-memory task. Subjects classified as 'good' or 'poor' imagers, according to their scores in the Vividness of Visual Imagery Questionnaire (VVIQ; Marks, 1972), were to detect as rapidly as possible differences between pairs of similar pictures presented consecutively. No coding instructions were given and the mnemonic strategies used were analysed by studying subjective reports and objective performance measurements. The results indicated that the subjects utilized two main strategies--a detail or an image strategy. The detail strategy was the more efficient. In accordance with a previous study (Berger & Gaunitz, 1977), it was found that the VVIQ did not discriminate between performance by 'good' and 'poor' imagers. However, among subjects who used the image strategy, 'good' imagers performed more rapidly than 'poor' imagers. Self-rated imagery may then have some value in predicting performance among individuals shown to have utilized an image strategy.
NASA Astrophysics Data System (ADS)
Ghafaryasl, Babak; Baart, Robert; de Boer, Johannes F.; Vermeer, Koenraad A.; van Vliet, Lucas J.
2017-02-01
Optical coherence tomography (OCT) yields high-resolution, three-dimensional images of the retina. A better understanding of retinal nerve fiber bundle (RNFB) trajectories in combination with visual field data may be used for future diagnosis and monitoring of glaucoma. However, manual tracing of these bundles is a tedious task. In this work, we present an automatic technique to estimate the orientation of RNFBs from volumetric OCT scans. Our method consists of several steps, starting from automatic segmentation of the RNFL. Then, a stack of en face images around the posterior nerve fiber layer interface was extracted. The image showing the best visibility of RNFB trajectories was selected for further processing. After denoising the selected en face image, a semblance structure-oriented filter was applied to probe the strength of local linear structure in a discrete set of orientations creating an orientation space. Gaussian filtering along the orientation axis in this space is used to find the dominant orientation. Next, a confidence map was created to supplement the estimated orientation. This confidence map was used as pixel weight in normalized convolution to regularize the semblance filter response after which a new orientation estimate can be obtained. Finally, after several iterations an orientation field corresponding to the strongest local orientation was obtained. The RNFB orientations of six macular scans from three subjects were estimated. For all scans, visual inspection shows a good agreement between the estimated orientation fields and the RNFB trajectories in the en face images. Additionally, a good correlation between the orientation fields of two scans of the same subject was observed. Our method was also applied to a larger field of view around the macula. Manual tracing of the RNFB trajectories shows a good agreement with the automatically obtained streamlines obtained by fiber tracking.
Congdon, Nathan; Yan, Xixi; Lansingh, Van; Sisay, Alemayehu; Müller, Andreas; Chan, Ving; Jin, Ling; Meltzer, Mirjam E; Karumanchi, Sasipriya M; Guan, Chunhong; Vuong, Quy; Rivera, Nelson; McCleod-Omawale, Joan; He, Mingguang
2013-07-01
Poor follow-up after cataract surgery in developing countries makes assessment of operative quality uncertain. We aimed to assess two strategies to measure visual outcome: recording the visual acuity of all patients 3 or fewer days postoperatively (early postoperative assessment), and recording that of only those patients who returned for the final follow-up examination after 40 or more days without additional prompting. Each of 40 centres in ten countries in Asia, Africa, and Latin America recruited 40-120 consecutive surgical cataract patients. Operative-eye best-corrected visual acuity and uncorrected visual acuity were recorded before surgery, 3 or fewer days postoperatively, and 40 or more days postoperatively. Clinics logged whether each patient had returned for the final follow-up examination without additional prompting, had to be actively encouraged to return, or had to be examined at home. Visual outcome for each centre was defined as the proportion of patients with uncorrected visual acuity of 6/18 or better minus the proportion with uncorrected visual acuity of 6/60 or worse, and was calculated for each participating hospital with results from the early assessment of all patients and the late assessment of only those returning unprompted, with results from the final follow-up assessment for all patients used as the standard. Of 3708 participants, 3441 (93%) had final follow-up vision data recorded 40 or more days after surgery, 1831 of whom (51% of the 3581 total participants for whom mode of follow-up was recorded) had returned to the clinic without additional prompting. Visual outcome by hospital from early postoperative and final follow-up assessment for all patients were highly correlated (Spearman's rs=0·74, p<0·0001). Visual outcome from final follow-up assessment for all patients and for only those who returned without additional prompting were also highly correlated (rs=0·86, p<0·0001), even for the 17 hospitals with unprompted return rates of less than 50% (rs=0·71, p=0·002). When we divided hospitals into top 25%, middle 50%, and bottom 25% by visual outcome, classification based on final follow-up assessment for all patients was the same as that based on early postoperative assessment for 27 (68%) of 40 centres, and the same as that based on data from patients who returned without additional prompting in 31 (84%) of 37 centres. Use of glasses to optimise vision at the time of the early and late examinations did not further improve the correlations. Early vision assessment for all patients and follow-up assessment only for patients who return to the clinic without prompting are valid measures of operative quality in settings where follow-up is poor. ORBIS International, Fred Hollows Foundation, Helen Keller International, International Association for the Prevention of Blindness Latin American Office, Aravind Eye Care System. Copyright © 2013 Congdon et al. Open Access article distributed under the terms of CC BY. Published by .. All rights reserved.
Approaches to determining Final Ecosystem Goods and Services: Benefits and Beneficiaries
By nature, the concept of ‘Final’ Ecosystem Goods and Services (FEGS) poses the question; to what or to whom are these goods and services final? We identify two main approaches theoreticians and practitioners are using to define and perceive FEGS (note: we recognize t...
A GPU-based mipmapping method for water surface visualization
NASA Astrophysics Data System (ADS)
Li, Hua; Quan, Wei; Xu, Chao; Wu, Yan
2018-03-01
Visualization of water surface is a hot topic in computer graphics. In this paper, we presented a fast method to generate wide range of water surface with good image quality both near and far from the viewpoint. This method utilized uniform mesh and Fractal Perlin noise to model water surface. Mipmapping technology was enforced to the surface textures, which adjust the resolution with respect to the distance from the viewpoint and reduce the computing cost. Lighting effect was computed based on shadow mapping technology, Snell's law and Fresnel term. The render pipeline utilizes a CPU-GPU shared memory structure, which improves the rendering efficiency. Experiment results show that our approach visualizes water surface with good image quality at real-time frame rates performance.
Takeuchi, Masato; Yano, Ikuko; Ito, Satoko; Sugimoto, Mitsuhiro; Yamamoto, Shota; Yonezawa, Atsushi; Ikeda, Akio; Matsubara, Kazuo
2017-04-01
Topiramate is a second-generation antiepileptic drug used as monotherapy and adjunctive therapy in adults and children with partial seizures. A population pharmacokinetic (PPK) analysis was performed to improve the topiramate dosage adjustment for individualized treatment. Patients whose steady-state serum concentration of topiramate was routinely monitored at Kyoto University Hospital from April 2012 to March 2013 were included in the model-building data. A nonlinear mixed effects modeling program was used to evaluate the influence of covariates on topiramate pharmacokinetics. The obtained PPK model was evaluated by internal model validations, including goodness-of-fit plots and prediction-corrected visual predictive checks, and was externally confirmed using the validation data from January 2015 to December 2015. A total of 177 steady-state serum concentrations from 93 patients were used for the model-building analysis. The patients' age ranged from 2 to 68 years, and body weight ranged from 8.6 to 105 kg. The median serum concentration of topiramate was 1.7 mcg/mL, and half of the patients received carbamazepine coadministration. Based on a one-compartment model with first order absorption and elimination, the apparent volume of distribution was 105 L/70 kg, and the apparent clearance was allometrically related to the body weight as 2.25 L·h·70 kg without carbamazepine or phenytoin. Combination treatment with carbamazepine or phenytoin increased the apparent clearance to 3.51 L·h·70 kg. Goodness-of-fit plots, prediction-corrected visual predictive check, and external validation using the validation data from 43 patients confirmed an appropriateness of the final model. Simulations based on the final model showed that dosage adjustments allometrically scaling to body weight can equalize the serum concentrations in children of various ages and adults. The PPK model, using the power scaling of body weight, effectively elucidated the topiramate serum concentration profile ranging from pediatric to adult patients. Dosage adjustments based on body weight and concomitant antiepileptic drug help obtain the dosage of topiramate necessary to reach an effective concentration in each individual.
Clinical characteristics and outcomes of fall-related open globe injuries in Japan.
Morikawa, Shohei; Okamoto, Yoshifumi; Okamoto, Fumiki; Inomoto, Naoki; Ishikawa, Hiroto; Harimoto, Kozo; Ueda, Tetsuo; Sakamoto, Taiji; Oshika, Tetsuro
2018-07-01
To investigate the clinical characteristics and visual outcomes in patients with fall-related open globe injuries and to evaluate differences between fall-related and non-fall-related open globe injuries in Japan. A retrospective review of patients with open globe injury who presented to Japan-Clinical Research of Study (J-CREST) hospitals between 2005 and 2015 was enrolled. Clinical information including age, sex, initial visual acuity, final visual acuity, type of injury, status of the crystalline lens, zone of injury, wound length, presence of retinal detachment, proliferative vitreoretinopathy, expulsive hemorrhage, and endophthalmitis was recorded. A total of 374 eyes were enrolled, of which 120 (32.1%) suffered from fall-related injury with average age of 73.7 ± 15.9 years (range, 11-101 years). A majority of patients were female (55.8%). Of 120 patients with fall-related injury, 109 (90.8%) presented with rupture and 11 (9.2%) with laceration. A multiple regression analysis revealed that final visual acuity was significantly associated with initial visual acuity (r = 0.99, P < 0.001). Compared to non-fall-related open globe injuries, fall-related open globe injuries were associated with elderly age, female sex, poorer initial and final visual acuity, rupture, absence of the lens, larger wound size, retinal detachment, expulsive hemorrhage, and absence of endophthalmitis (P < 0.01). Fall-related open globe injuries were more frequent in elderly female and accompanied by larger wound lengths and severer ocular complications. Visual outcomes in patients with fall-related open globe injuries were related to initial visual acuity.
Demehri, S; Muhit, A; Zbijewski, W; Stayman, J W; Yorkston, J; Packard, N; Senn, R; Yang, D; Foos, D; Thawait, G K; Fayad, L M; Chhabra, A; Carrino, J A; Siewerdsen, J H
2015-06-01
To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80 kVp-108mAs for CBCT; 120 kVp- 300 mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated "excellent" or "good" (median scores 5 and 4) for "bone" and "soft tissue" visualization tasks. Hand CBCT images were rated "excellent" or "adequate" (median scores 5 and 3) for "bone" and "soft tissue" visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ~ 0.26-0.92), and interobserver agreement was fair to moderate (κ ~ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. • CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were "excellent" for "bone" and "good/adequate" for "soft tissue" visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.
Machinability of Minor Wooden Species before and after Modification with Thermo-Vacuum Technology
Sandak, Jakub; Goli, Giacomo; Cetera, Paola; Sandak, Anna; Cavalli, Alberto; Todaro, Luigi
2017-01-01
The influence of the thermal modification process on wood machinability was investigated with four minor species of low economic importance. A set of representative experimental samples was machined to the form of disks with sharp and dull tools. The resulting surface quality was visually evaluated by a team of experts according to the American standard procedure ASTM D-1666-87. The objective quantification of the surface quality was also done by means of a three dimensions (3D) surface scanner for the whole range of grain orientations. Visual assessment and 3D surface analysis showed a good agreement in terms of conclusions. The best quality of the wood surface was obtained when machining thermally modified samples. The positive effect of the material modification was apparent when cutting deodar cedar, black pine and black poplar in unfavorable conditions (i.e., against the grain). The difference was much smaller for an easy-machinability specie such as Italian alder. The use of dull tools resulted in the worst surface quality. Thermal modification has shown a very positive effect when machining with dull tools, leading to a relevant increment of the final surface smoothness. PMID:28772480
Machinability of Minor Wooden Species before and after Modification with Thermo-Vacuum Technology.
Sandak, Jakub; Goli, Giacomo; Cetera, Paola; Sandak, Anna; Cavalli, Alberto; Todaro, Luigi
2017-01-28
The influence of the thermal modification process on wood machinability was investigated with four minor species of low economic importance. A set of representative experimental samples was machined to the form of disks with sharp and dull tools. The resulting surface quality was visually evaluated by a team of experts according to the American standard procedure ASTM D-1666-87. The objective quantification of the surface quality was also done by means of a three dimensions (3D) surface scanner for the whole range of grain orientations. Visual assessment and 3D surface analysis showed a good agreement in terms of conclusions. The best quality of the wood surface was obtained when machining thermally modified samples. The positive effect of the material modification was apparent when cutting deodar cedar, black pine and black poplar in unfavorable conditions (i.e., against the grain). The difference was much smaller for an easy-machinability specie such as Italian alder. The use of dull tools resulted in the worst surface quality. Thermal modification has shown a very positive effect when machining with dull tools, leading to a relevant increment of the final surface smoothness.
ERIC Educational Resources Information Center
Avance, Lyonel D.; Carr, Dorothy B.
Presented is the final report of a project to develop and field test audio and visual media to accompany developmentally sequenced activities appropriate for a physical education program for handicapped children from preschool through high school. Brief sections cover the following: the purposes and accomplishments of the project; the population…
ERIC Educational Resources Information Center
Ding, Daniel D.
2000-01-01
Presents historical roots of page design principles, arguing that current theories and practices of document design have their roots in gender-related theories of images. Claims visual design should be evaluated regarding the rhetorical situation in which the design is used. Focuses on visual images of documents in professional communication,…
Creating opportunities in astronomy: Communication for people who are blind or visually impaired
NASA Astrophysics Data System (ADS)
Grice, N.
2008-06-01
Astronomy is such a visually rich field that you may wonder if access is possible for a person who is blind or visually impaired. The good news is that with creative strategies and available resources, students who are blind need not be excluded. Braille text, tactile illustrations, handson models, and descriptive narration can remove many barriers.
"The Gallery": An Experiential Approach to Visual Aid Construction and Analysis in the Classroom
ERIC Educational Resources Information Center
Tyma, Adam W.
2008-01-01
When working with students to prepare oral presentations, the question--"What makes an effective visual aid?"--often arises. Most teachers realize the value of visual aids, but what makes them effective is sometimes unclear. There seems to be a disconnect between what the teacher, the textbook, and the student actually perceive to be a "good"…
Efficiency of bowel preparation for capsule endoscopy examination: a meta-analysis.
Niv, Yaron
2008-03-07
Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as "good" in 78% of the examinations performed with preparation and 49% performed without (P<0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum.
Cataract: trends in surgical procedures and visual outcomes; a study in a tertiary care hospital.
Naeem, Mohammad; Khan, Ayasha; Khan, Muhammad Zia-ul-Islam; Adil, Muhammad; Abbas, Syed Hussain; Khan, Muhammad Usman; Naz, Syeda Maria
2012-03-01
To determine the current procedures in practice and visual outcome following a cataract surgery. The study was conducted from January 7 to April 7, 2011 in the Eye Unit of the Lady Reading Hospital, Peshawar, involving 181 patients. Basic demographics of the patients as well as the type of cataract surgery were noted. Risk factors like diabetes mellitus and glaucoma were also noted for each patient. A pre-operative visual acuity was determined. The patient was examined after two months to determine the visual improvement. Out of 181 patients, 117 were males and 64 were females. Age ranged from 5 years to 83 years with a median age of 60. Most common procedure performed (60.2%) was extra capsular cataract extraction with posterior chamber intraocular lense (ECCE), followed by Phacoemulsification (24.3%). Visual outcome was good in 88.3%, borderline in 8.3% and poor in 3.3% patients. The main reasons for poor visual outcomes were diabetic retinopathy 42.8%, glaucoma-related vision loss 19.0%, history of trauma with retinal detachment 9.5%, and age-related macular degeneration 9.5%. Poor visual outcome was found in diabetic and Glaucoma patients. Surgical complications (3.8%) were rare. Overall a good visual outcome was noted in cataract surgery, which was similar to World Health Organisation guidelines. Extra capsular cataract extraction was the most common procedure followed by Phacoemulsification.
ERIC Educational Resources Information Center
Donnelly, Laura
2007-01-01
When teaching science to kids, a visual approach is good. Humor is also good. And blowing things up is really, really good. At least that is what educators at the Exploratorium in San Francisco have found in the nine years since the museum began producing a live, off-the-cuff competition called Iron Science Teacher. Modeled after the Japanese cult…
A Good Image Model Eases Restoration
2002-02-06
edges for image understanding and visual communication . Edges are indeed an intrinsic feature for images since they define, segment, and correlate...as possible for the purpose of efficient neuronal data compression and visual communication [Don00]. Such representation is achieved by having the
Kim, Min-Beom; Shim, Hyun-Yong; Jin, Sun Hwa; Kang, Soojin; Woo, Jihwan; Han, Jong Chul; Lee, Ji Young; Kim, Martha; Cho, Yang-Sun
2016-01-01
Evidence of visual-auditory cross-modal plasticity in deaf individuals has been widely reported. Superior visual abilities of deaf individuals have been shown to result in enhanced reactivity to visual events and/or enhanced peripheral spatial attention. The goal of this study was to investigate the association between visual-auditory cross-modal plasticity and speech perception in post-lingually deafened, adult cochlear implant (CI) users. Post-lingually deafened adults with CIs (N = 14) and a group of normal hearing, adult controls (N = 12) participated in this study. The CI participants were divided into a good performer group (good CI, N = 7) and a poor performer group (poor CI, N = 7) based on word recognition scores. Visual evoked potentials (VEP) were recorded from the temporal and occipital cortex to assess reactivity. Visual field (VF) testing was used to assess spatial attention and Goldmann perimetry measures were analyzed to identify differences across groups in the VF. The association of the amplitude of the P1 VEP response over the right temporal or occipital cortex among three groups (control, good CI, poor CI) was analyzed. In addition, the association between VF by different stimuli and word perception score was evaluated. The P1 VEP amplitude recorded from the right temporal cortex was larger in the group of poorly performing CI users than the group of good performers. The P1 amplitude recorded from electrodes near the occipital cortex was smaller for the poor performing group. P1 VEP amplitude in right temporal lobe was negatively correlated with speech perception outcomes for the CI participants (r = -0.736, P = 0.003). However, P1 VEP amplitude measures recorded from near the occipital cortex had a positive correlation with speech perception outcome in the CI participants (r = 0.775, P = 0.001). In VF analysis, CI users showed narrowed central VF (VF to low intensity stimuli). However, their far peripheral VF (VF to high intensity stimuli) was not different from the controls. In addition, the extent of their central VF was positively correlated with speech perception outcome (r = 0.669, P = 0.009). Persistent visual activation in right temporal cortex even after CI causes negative effect on outcome in post-lingual deaf adults. We interpret these results to suggest that insufficient intra-modal (visual) compensation by the occipital cortex may cause negative effects on outcome. Based on our results, it appears that a narrowed central VF could help identify CI users with poor outcomes with their device. PMID:26848755
The attentive brain: insights from developmental cognitive neuroscience.
Amso, Dima; Scerif, Gaia
2015-10-01
Visual attention functions as a filter to select environmental information for learning and memory, making it the first step in the eventual cascade of thought and action systems. Here, we review studies of typical and atypical visual attention development and explain how they offer insights into the mechanisms of adult visual attention. We detail interactions between visual processing and visual attention, as well as the contribution of visual attention to memory. Finally, we discuss genetic mechanisms underlying attention disorders and how attention may be modified by training.
Gupta, Arvind; Srinivasan, Renuka; Babu, K Ramesh; Setia, Sajita
2010-01-01
To compare the clinical presentation and final visual outcome of open globe injuries in children and adults in a referral hospital over a 30-month period. This is an institutional-based prospective study of open globe injuries cases presenting in the emergency department between July 2003 and December 2005. Patients were divided in 2 groups: group 1, children (2-15 years), and group 2, adults (>15 years). All the patients were admitted and emergency surgical interventions were undertaken. The clinical features at presentation and the final visual acuity are compared. Chi-square and Fisher exact tests were used for statistical analysis. Ninety and 84 patients were included in group 1 and group 2, respectively. The most common places of injuries were home or while playing outdoor games in group 1 (67%) and workplace in group 2 (53.5%). The presenting features were significantly more grave in group 2. These included poor presenting visual acuity (p=0.012), vitreous prolapse (p=0.002), presence of relative afferent pupillary defect (p=0.001), and incidence of endophthalmitis (p=0.004). Time interval between injury and surgical intervention (p=0.018) was better in group 2. Other features, such as presence of hyphema, uveal tissue prolapse, cataract, intraocular foreign body, and length or location of laceration were similar in both groups. The final visual outcome was similar in the groups (p = 0.21), with approximately half of the patients achieving vision of 20/60 or better in each group. The majority of injuries in children and adults occurred in their homes or workplaces, respectively. Although the clinical presentations of open globe injuries were significantly more grave in adults than in children, the final visual outcomes were similar.
44 CFR 9.12 - Final public notice.
Code of Federal Regulations, 2011 CFR
2011-10-01
... good cause shown, be allowed for comment on the final notice. (c) For actions for which an... potential impact; and (6) Similarity of the actions, i.e., to the extent that they are susceptible of common...) After providing the final notice, the Agency shall, without good cause shown, wait at least 15 days...
44 CFR 9.12 - Final public notice.
Code of Federal Regulations, 2010 CFR
2010-10-01
... good cause shown, be allowed for comment on the final notice. (c) For actions for which an... potential impact; and (6) Similarity of the actions, i.e., to the extent that they are susceptible of common...) After providing the final notice, the Agency shall, without good cause shown, wait at least 15 days...
An assembly system based on industrial robot with binocular stereo vision
NASA Astrophysics Data System (ADS)
Tang, Hong; Xiao, Nanfeng
2017-01-01
This paper proposes an electronic part and component assembly system based on an industrial robot with binocular stereo vision. Firstly, binocular stereo vision with a visual attention mechanism model is used to get quickly the image regions which contain the electronic parts and components. Secondly, a deep neural network is adopted to recognize the features of the electronic parts and components. Thirdly, in order to control the end-effector of the industrial robot to grasp the electronic parts and components, a genetic algorithm (GA) is proposed to compute the transition matrix and the inverse kinematics of the industrial robot (end-effector), which plays a key role in bridging the binocular stereo vision and the industrial robot. Finally, the proposed assembly system is tested in LED component assembly experiments, and the results denote that it has high efficiency and good applicability.
Research on image complexity evaluation method based on color information
NASA Astrophysics Data System (ADS)
Wang, Hao; Duan, Jin; Han, Xue-hui; Xiao, Bo
2017-11-01
In order to evaluate the complexity of a color image more effectively and find the connection between image complexity and image information, this paper presents a method to compute the complexity of image based on color information.Under the complexity ,the theoretical analysis first divides the complexity from the subjective level, divides into three levels: low complexity, medium complexity and high complexity, and then carries on the image feature extraction, finally establishes the function between the complexity value and the color characteristic model. The experimental results show that this kind of evaluation method can objectively reconstruct the complexity of the image from the image feature research. The experimental results obtained by the method of this paper are in good agreement with the results of human visual perception complexity,Color image complexity has a certain reference value.
Multi-focus image fusion algorithm using NSCT and MPCNN
NASA Astrophysics Data System (ADS)
Liu, Kang; Wang, Lianli
2018-04-01
Based on nonsubsampled contourlet transform (NSCT) and modified pulse coupled neural network (MPCNN), the paper proposes an effective method of image fusion. Firstly, the paper decomposes the source image into the low-frequency components and high-frequency components using NSCT, and then processes the low-frequency components by regional statistical fusion rules. For high-frequency components, the paper calculates the spatial frequency (SF), which is input into MPCNN model to get relevant coefficients according to the fire-mapping image of MPCNN. At last, the paper restructures the final image by inverse transformation of low-frequency and high-frequency components. Compared with the wavelet transformation (WT) and the traditional NSCT algorithm, experimental results indicate that the method proposed in this paper achieves an improvement both in human visual perception and objective evaluation. It indicates that the method is effective, practical and good performance.
Neurolinguistic Programming Examined: Imagery, Sensory Mode, and Communication.
ERIC Educational Resources Information Center
Fromme, Donald K.; Daniell, Jennifer
1984-01-01
Tested Neurolinguistic Programming (NLP) assumptions by examining intercorrelations among response times of students (N=64) for extracting visual, auditory, and kinesthetic information from alphabetic images. Large positive intercorrelations were obtained, the only outcome not compatible with NLP. Good visualizers were significantly better in…
Stochastic digital holography for visualizing inside strongly refracting transparent objects.
Desse, Jean-Michel; Picart, Pascal
2015-01-01
This paper presents a digital holographic method to visualize and measure refractive index variations, convection currents, or thermal gradients, occurring inside a transparent and refracting object. The proof of principle is provided through the visualization of refractive index variation inside a lighting bulb. Comparison with transmission and reflection holography is also provided. A very good agreement is obtained, thus validating the proposed approach.
Research on Multimedia Access to Microcomputers for Visually Impaired Youth.
ERIC Educational Resources Information Center
Ashcroft, S. C.
This final report discusses the outcomes of a federally funded project that studied visual, auditory, and tactual methods designed to give youth with visual impairments access to microcomputers for curricular, prevocational, and avocational purposes. The objectives of the project were: (1) to research microcomputer systems that could be made…
Viewing the World: Visual Inquiry in International Settings
ERIC Educational Resources Information Center
Munn, Jean Correll
2012-01-01
This teaching note describes a course, Viewing the World: Visual Inquiry in International Settings, which the author taught in the Czech Republic in 2009. Five students successfully completed the course, which consisted of designing a project, collecting and analyzing visual data, presenting findings, and writing a final report of a qualitative…
Feature extraction inspired by V1 in visual cortex
NASA Astrophysics Data System (ADS)
Lv, Chao; Xu, Yuelei; Zhang, Xulei; Ma, Shiping; Li, Shuai; Xin, Peng; Zhu, Mingning; Ma, Hongqiang
2018-04-01
Target feature extraction plays an important role in pattern recognition. It is the most complicated activity in the brain mechanism of biological vision. Inspired by high properties of primary visual cortex (V1) in extracting dynamic and static features, a visual perception model was raised. Firstly, 28 spatial-temporal filters with different orientations, half-squaring operation and divisive normalization were adopted to obtain the responses of V1 simple cells; then, an adjustable parameter was added to the output weight so that the response of complex cells was got. Experimental results indicate that the proposed V1 model can perceive motion information well. Besides, it has a good edge detection capability. The model inspired by V1 has good performance in feature extraction and effectively combines brain-inspired intelligence with computer vision.
Effects of Individual Differences in Working Memory on Plan Presentational Choices
Tintarev, Nava; Masthoff, Judith
2016-01-01
This paper addresses research questions that are central to the area of visualization interfaces for decision support: (RQ1) whether individual user differences in working memory should be considered when choosing how to present visualizations; (RQ2) how to present the visualization to support effective decision making and processing; and (RQ3) how to evaluate the effectiveness of presentational choices. These questions are addressed in the context of presenting plans, or sequences of actions, to users. The experiments are conducted in several domains, and the findings are relevant to applications such as semi-autonomous systems in logistics. That is, scenarios that require the attention of humans who are likely to be interrupted, and require good performance but are not time critical. Following a literature review of different types of individual differences in users that have been found to affect the effectiveness of presentational choices, we consider specifically the influence of individuals' working memory (RQ1). The review also considers metrics used to evaluate presentational choices, and types of presentational choices considered. As for presentational choices (RQ2), we consider a number of variants including interactivity, aggregation, layout, and emphasis. Finally, to evaluate the effectiveness of plan presentational choices (RQ3) we adopt a layered-evaluation approach and measure performance in a dual task paradigm, involving both task interleaving and evaluation of situational awareness. This novel methodology for evaluating visualizations is employed in a series of experiments investigating presentational choices for a plan. A key finding is that emphasizing steps (by highlighting borders) can improve effectiveness on a primary task, but only when controlling for individual variation in working memory. PMID:27899905
Rabbi, Md Shifat-E; Hasan, Md Kamrul
2017-02-01
Strain imaging though for solid lesions provides an effective way for determining their pathologic condition by displaying the tissue stiffness contrast, for fluid filled lesions such an imaging is yet an open problem. In this paper, we propose a novel speckle content based strain imaging technique for visualization and classification of fluid filled lesions in elastography after automatic identification of the presence of fluid filled lesions. Speckle content based strain, defined as a function of speckle density based on the relationship between strain and speckle density, gives an indirect strain value for fluid filled lesions. To measure the speckle density of the fluid filled lesions, two new criteria based on oscillation count of the windowed radio frequency signal and local variance of the normalized B-mode image are used. An improved speckle tracking technique is also proposed for strain imaging of the solid lesions and background. A wavelet-based integration technique is then proposed for combining the strain images from these two techniques for visualizing both the solid and fluid filled lesions from a common framework. The final output of our algorithm is a high quality composite strain image which can effectively visualize both solid and fluid filled breast lesions in addition to the speckle content of the fluid filled lesions for their discrimination. The performance of our algorithm is evaluated using the in vivo patient data and compared with recently reported techniques. The results show that both the solid and fluid filled lesions can be better visualized using our technique and the fluid filled lesions can be classified with good accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.
Effects of Individual Differences in Working Memory on Plan Presentational Choices.
Tintarev, Nava; Masthoff, Judith
2016-01-01
This paper addresses research questions that are central to the area of visualization interfaces for decision support: (RQ1) whether individual user differences in working memory should be considered when choosing how to present visualizations; (RQ2) how to present the visualization to support effective decision making and processing; and (RQ3) how to evaluate the effectiveness of presentational choices. These questions are addressed in the context of presenting plans, or sequences of actions, to users. The experiments are conducted in several domains, and the findings are relevant to applications such as semi-autonomous systems in logistics. That is, scenarios that require the attention of humans who are likely to be interrupted, and require good performance but are not time critical. Following a literature review of different types of individual differences in users that have been found to affect the effectiveness of presentational choices, we consider specifically the influence of individuals' working memory (RQ1). The review also considers metrics used to evaluate presentational choices, and types of presentational choices considered. As for presentational choices (RQ2), we consider a number of variants including interactivity, aggregation, layout, and emphasis. Finally, to evaluate the effectiveness of plan presentational choices (RQ3) we adopt a layered-evaluation approach and measure performance in a dual task paradigm, involving both task interleaving and evaluation of situational awareness. This novel methodology for evaluating visualizations is employed in a series of experiments investigating presentational choices for a plan. A key finding is that emphasizing steps (by highlighting borders) can improve effectiveness on a primary task, but only when controlling for individual variation in working memory.
ERIC Educational Resources Information Center
Meyer, Philip A.
Reported were four experiments which investigated the developmental and mental retardation aspects of an initial stage of visual information processing termed iconic memory. The stage was explained to involve processing visual stimuli prior to sensation and through to recognition. In three of the four experiments, the paradigm of visual masking…
Visual Analytics and Storytelling through Video
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, Pak C.; Perrine, Kenneth A.; Mackey, Patrick S.
2005-10-31
This paper supplements a video clip submitted to the Video Track of IEEE Symposium on Information Visualization 2005. The original video submission applies a two-way storytelling approach to demonstrate the visual analytics capabilities of a new visualization technique. The paper presents our video production philosophy, describes the plot of the video, explains the rationale behind the plot, and finally, shares our production experiences with our readers.
Understanding Soldier Robot Teams in Virtual Environments
2006-06-01
often with Verbal only communication than the Verbal plus Visual communication . This was mainly attributed to the fact that the transmitted images...performance. Participants ranked every Verbal plus Visual communication conditions higher than any Verbal only communication condition. Finally, there were...UV and RM locations. Communication was either verbal only (either FF or via radio, depending on the location) or verbal plus visual. When visual
ERIC Educational Resources Information Center
San Francisco Unified School District, CA.
This is a selected bibliography of some good and some outstanding audio-visual educational materials in the library of the Educational Materials Bureau, Audio-Visual Education Section, that may be considered by particular interest in the study of black Americans. The bibliography is arranged alphabetically within these subject areas: I. African…
Management of corneal decompensation 4 decades after Sputnik intraocular lens implantation.
Hirji, Nashila; Nanavaty, Mayank A
2015-01-01
We report an unusual case of corneal decompensation occurring four decades after complicated cataract extraction with implantation of a Sputnik intraocular lens (IOL) and highlight the clinical and practical issues faced in managing corneal decompensation with a Sputnik IOL. A 72-year-old woman presented with deterioration of the vision in her left eye, four decades after intracapsular cataract extraction with Sputnik IOL implantation. Ocular examination revealed diffuse corneal edema and thickened vitreous strands in the anterior chamber. Her best-corrected visual acuity (BCVA) worsened to 6/60 within 3 months. Anterior vitrectomy and inferior iridectomy combined with Desçemet-stripping automated endothelial keratoplasty was performed. The procedure was successful, with the patient achieving best-corrected visual acuity of 6/6 at 8 months postoperatively. Corneal decompensation after Sputnik IOL implantation can occur four decades later. When the historical preoperative visual acuity is good in such cases, careful anterior vitrectomy with Desçemet-stripping automated endothelial keratoplasty provides good visual rehabilitation.
Visual outcome in Japanese patients with Acanthamoeba keratitis.
Yamazoe, K; Yamamoto, Y; Shimazaki-Den, S; Shimazaki, J
2012-04-01
To identify prognostic factors affecting visual outcome in Acanthamoeba keratitis (AK) treated with topical chlorhexidine gluconate (CHG). A total of 35 eyes in 34 patients with AK were treated with 0.02% topical CHG. Patients were divided into two groups according to the final visual outcome: Group 1, final visual acuity (VA) of 20/25 or greater (22 eyes); Group 2, less than 20/25 (13 eyes). We compared these groups and evaluated the effectiveness of topical CHG compared with outcomes in previous reports. Ring infiltrate was observed more often in Group 2 (4.5% vs 61.5%, OR 33.6, 95% confidence interval (CI) 3.4-333.9, P<0.01). The duration between onset and diagnosis of AK was significantly longer (24.9 days vs 48.4 days, OR 1.03, 95% CI 1.00-1.06, P = 0.04) and VA at initial examination (log MAR) significantly lower (0.47 vs 1.59, OR 25.5, 95% CI 3.4-186.7, P<0.01) in Group 2 (visual outcome <20/25). Multivariate analysis revealed that only VA at initial examination was independently associated with worse visual outcome (adjusted OR 24.5, 95% CI 1.9-312.6, P=0.01). Seventeen (85.0%) of the 20 eyes diagnosed within 1 month and 24 (82.8%) of 29 eyes diagnosed within 2 months achieved a VA of 20/40 or greater. VA at initial examination was the most predictive factors for final visual outcome in AK. Topical CHG was comparably effective to other treatments, including polyhexamethyl biguanide and propamidine isethionate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Houston, Johnny L; Geter, Kerry
This Project?s third year of implementation in 2007-2008, the final year, as designated by Elizabeth City State University (ECSU), in cooperation with the National Association of Mathematicians (NAM) Inc., in an effort to promote research and research training programs in computational science ? scientific visualization (CSSV). A major goal of the Project was to attract the energetic and productive faculty, graduate and upper division undergraduate students of diverse ethnicities to a program that investigates science and computational science issues of long-term interest to the Department of Energy (DoE) and the nation. The breadth and depth of computational science?scientific visualization andmore » the magnitude of resources available are enormous for permitting a variety of research activities. ECSU?s Computational Science-Science Visualization Center will serve as a conduit for directing users to these enormous resources.« less
Schneider, M M; Balke, M; Koenen, P; Fröhlich, M; Wafaisade, A; Bouillon, B; Banerjee, M
2016-07-01
The reliability of the Rockwood classification, the gold standard for acute acromioclavicular (AC) joint separations, has not yet been tested. The purpose of this study was to investigate the reliability of visual and measured AC joint lesion grades according to the Rockwood classification. Four investigators (two shoulder specialists and two second-year residents) examined radiographs (bilateral panoramic stress and axial views) in 58 patients and graded the injury according to the Rockwood classification using the following sequence: (1) visual classification of the AC joint lesion, (2) digital measurement of the coracoclavicular distance (CCD) and the horizontal dislocation (HD) with Osirix Dicom Viewer (Pixmeo, Switzerland), (3) classification of the AC joint lesion according to the measurements and (4) repetition of (1) and (2) after repeated anonymization by an independent physician. Visual and measured Rockwood grades as well as the CCD and HD of every patient were documented, and a CC index was calculated (CCD injured/CCD healthy). All records were then used to evaluate intra- and interobserver reliability. The disagreement between visual and measured diagnosis ranged from 6.9 to 27.6 %. Interobserver reliability for visual diagnosis was good (0.72-0.74) and excellent (0.85-0.93) for measured Rockwood grades. Intraobserver reliability was good to excellent (0.67-0.93) for visual diagnosis and excellent for measured diagnosis (0.90-0.97). The correlations between measurements of the axial view varied from 0.68 to 0.98 (good to excellent) for interobserver reliability and from 0.90 to 0.97 (excellent) for intraobserver reliability. Bilateral panoramic stress and axial radiographs are reliable examinations for grading AC joint injuries according to Rockwood's classification. Clinicians of all experience levels can precisely classify AC joint lesions according to the Rockwood classification. We recommend to grade acute ACG lesions by performing a digital measurement instead of a sole visual diagnosis because of the higher intra- and interobserver reliability. Case series, Level IV.
Furia, John P
2008-03-01
High-energy extracorporeal shock wave therapy has been shown to be an effective treatment for chronic insertional Achilles tendinopathy. The results of high-energy shock wave therapy for chronic noninsertional Achilles tendinopathy have not been determined. Shock wave therapy is an effective treatment for noninsertional Achilles tendinopathy. Case control study; Level of evidence, 3. Thirty-four patients with chronic noninsertional Achilles tendinopathy were treated with a single dose of high-energy shock wave therapy (shock wave therapy group; 3000 shocks; 0.21 mJ/mm(2); total energy flux density, 604 mJ/mm(2)). Thirty-four patients with chronic noninsertional Achilles tendinopathy were treated not with shock wave therapy but with additional forms of nonoperative therapy (control group). All shock wave therapy procedures were performed using regional anesthesia. Evaluation was by change in visual analog score and by Roles and Maudsley score. One month, 3 months, and 12 months after treatment, the mean visual analog scores for the control and shock wave therapy groups were 8.4 and 4.4 (P < .001), 6.5 and 2.9 (P < .001), and 5.6 and 2.2 (P < .001), respectively. At final follow-up, the number of excellent, good, fair, and poor results for the shock wave therapy and control groups were 12 and 0 (P < .001), 17 and 9 (P < .001), 5 and 17 (P < .001), and 0 and 8 (P < .001), respectively. A chi(2) analysis revealed that the percentage of patients with excellent ("1") or good ("2") Roles and Maudsley scores, that is, successful results, 12 months after treatment was statistically greater in the shock wave therapy group than in the control group (P < .001). Shock wave therapy is an effective treatment for chronic noninsertional Achilles tendinopathy.
Neural Pathways Conveying Novisual Information to the Visual Cortex
2013-01-01
The visual cortex has been traditionally considered as a stimulus-driven, unimodal system with a hierarchical organization. However, recent animal and human studies have shown that the visual cortex responds to non-visual stimuli, especially in individuals with visual deprivation congenitally, indicating the supramodal nature of the functional representation in the visual cortex. To understand the neural substrates of the cross-modal processing of the non-visual signals in the visual cortex, we firstly showed the supramodal nature of the visual cortex. We then reviewed how the nonvisual signals reach the visual cortex. Moreover, we discussed if these non-visual pathways are reshaped by early visual deprivation. Finally, the open question about the nature (stimulus-driven or top-down) of non-visual signals is also discussed. PMID:23840972
The Use of Final-Letter Braille Contractions: A Case Study
ERIC Educational Resources Information Center
Tallon, Emily M.; Herzberg, Tina S.
2013-01-01
Louis Braille developed a six-dot braille code in the early 1800s, thus creating an effective way for persons who are visually impaired to communicate through reading and writing (Holbrook, D'Andrea, & Sanford, 2011). Students with visual impairments require braille instruction from teachers of students with visual impairments, who are responsible…
Visual Imagery for Letters and Words. Final Report.
ERIC Educational Resources Information Center
Weber, Robert J.
In a series of six experiments, undergraduate college students visually imagined letters or words and then classified as rapidly as possible the imagined letters for some physical property such as vertical height. This procedure allowed for a preliminary assessment of the temporal parameters of visual imagination. The results delineate a number of…
ERIC Educational Resources Information Center
San Francisco Unified School District, CA.
This is a selected bibliography of some good and some outstanding audio-visual educational materials in the library of the Educational Materials Bureau, Audio-Visual Education Section, that may be considered of particular interest in the study of Asians and Asian-Americans. The bibliography is arranged alphabetically within the following subject…
ERIC Educational Resources Information Center
Tallman, Oliver H.
A digital simulation of a model for the processing of visual images is derived from known aspects of the human visual system. The fundamental principle of computation suggested by a biological model is a transformation that distributes information contained in an input stimulus everywhere in a transform domain. Each sensory input contributes under…
2014-06-10
The Food and Drug Administration (FDA or we) is issuing a final rule that adopts, with some modifications, the interim final rule (IFR) entitled "Current Good Manufacturing Practices, Quality Control Procedures, Quality Factors, Notification Requirements, and Records and Reports, for Infant Formula'' (February 10, 2014). This final rule affirms the IFR's changes to FDA's regulations and provides additional modifications and clarifications. The final rule also responds to certain comments submitted in response to the request for comments in the IFR.
2007-06-25
The Food and Drug Administration (FDA) is issuing a final rule regarding current good manufacturing practice (CGMP) for dietary supplements. The final rule establishes the minimum CGMPs necessary for activities related to manufacturing, packaging, labeling, or holding dietary supplements to ensure the quality of the dietary supplement. The final rule is one of many actions related to dietary supplements that we are taking to promote and protect the public health.
Application of Visual Attention in Seismic Attribute Analysis
NASA Astrophysics Data System (ADS)
He, M.; Gu, H.; Wang, F.
2016-12-01
It has been proved that seismic attributes can be used to predict reservoir. The joint of multi-attribute and geological statistics, data mining, artificial intelligence, further promote the development of the seismic attribute analysis. However, the existing methods tend to have multiple solutions and insufficient generalization ability, which is mainly due to the complex relationship between seismic data and geological information, and undoubtedly own partly to the methods applied. Visual attention is a mechanism model of the human visual system which can concentrate on a few significant visual objects rapidly, even in a mixed scene. Actually, the model qualify good ability of target detection and recognition. In our study, the targets to be predicted are treated as visual objects, and an object representation based on well data is made in the attribute dimensions. Then in the same attribute space, the representation is served as a criterion to search the potential targets outside the wells. This method need not predict properties by building up a complicated relation between attributes and reservoir properties, but with reference to the standard determined before. So it has pretty good generalization ability, and the problem of multiple solutions can be weakened by defining the threshold of similarity.
Equity, Equal Shares or Equal Final Outcomes? Group Goal Guides Allocations of Public Goods.
Kazemi, Ali; Eek, Daniel; Gärling, Tommy
2017-01-01
In an experiment we investigate preferences for allocation of a public good among group members who contributed unequally in providing the public good. Inducing the group goal of productivity resulted in preferences for equitable allocations, whereas inducing the group goals of harmony and social concern resulted in preferences for equal final outcomes. The study makes a contribution by simultaneously treating provision and allocation of a public good, thus viewing these as related processes. Another contribution is that a new paradigm is introduced that bears closer resemblance to real life public good dilemmas than previous research paradigms do.
Spanish Heritage and Influence in the Western Hemisphere.
ERIC Educational Resources Information Center
San Francisco Unified School District, CA.
This is a selected bibliography of some good and some outstanding audio-visual educational materials in the library of the Educational Materials Bureau, Audio-Visual Educational Section, that may be considered of particular interest in the study of Spanish heritage and influence in the Western Hemisphere. The bibliography is arranged…
The Teaching of Graphics and Design.
ERIC Educational Resources Information Center
Sullivan, Paul W.
This paper describes four journalism courses designed to develop students' visual sense and then channel that sense into the field of advertising. "Visual Communication" is a basic course in the elements of design which attempts to demonstrate to students that there are rules and order which comprise good design. "Publication…
How an Exchange of Perspectives Led to Tentative Ethical Guidelines for Visual Ethnography
ERIC Educational Resources Information Center
Pope, Clive C.; De Luca, Rosemary; Tolich, Martin
2010-01-01
Qualitative research, especially visual ethnography, is an iterative not a linear process, replete with good intentions, false starts, mistaken assumptions, miscommunication and a continually revised statement of the problem. That the camera freezes everything and everyone in the frame only complicates ethical considerations. This work, jointly…
Creating "Visual Legacies": Infographics as a Means of Interpreting and Sharing Research
ERIC Educational Resources Information Center
Thompson, Charee M.
2015-01-01
Guided by the principle "good data presentation is timeless," (Cressey, 2014, p.305), this unit project challenges students to engage an alternative means of sharing communication research and to realize the potential for their presentations to become "visual legacies" through the creation of infographics. Students encounter…
Reliability of Visual Inspection for Highway Bridges, Volume I : Final Report
DOT National Transportation Integrated Search
2001-06-01
This technical summary announces the findings of an investigation by the Federal Highway Administrations Nondestructive Evaluation Validation Center (NDEVC) concerning the reliability of Visual Inspection for highway bridges. Details and results a...
Yu, Bo; Chen, Yingbai; Ma, Yingjie; Tu, Yunhai; Wu, Wencan
2018-06-26
To evaluate the safety and outcomes of endoscopic trans-ethmosphenoid optic canal decompression (ETOCD) for children with indirect traumatic optic neuropathy (ITON). From July 1st, 2008 to July 1st, 2015, 62 children diagnosed with ITON who underwent ETOCD were reviewed. Main outcome measure was improvement in visual acuity after treatment. Altogether 62 children (62 eyes) with a mean age of 11.26 ± 4.14 years were included. Thirty-three (53.2%) of them had residual vision before surgery while 29 (46.8%) had no light perception (NLP). The overall visual acuity improvement rate after surgery was 54.84%. The improvement rate of patients with residual vision (69.70%) was significant higher than that of patients with no light perception (NLP) (37.9%) (P = 0.012). However, no significant difference was shown among patients with different residual vision (P = 0.630). Presence of orbital and/ or optic canal fracture and hemorrhage within the post-ethmoid and/or sphenoid sinus resulted in poor postoperative visual acuity, duration of presenting complaints did not affect final visual acuity or did not effect outcomes. Intervention performed in children presenting even after 7 days from the injury did not influence the final visual outcome. Three patients developed cerebrospinal fluid rhinorrhea and one encountered cavernous sinus hemorrhage during surgery. No other severe complications were observed. Children with residual vision had better postoperative visual prognosis and benefited more from ETOCD than children with NLP. Intervention performed in children presenting even after 7 days from the injury did not influence the final visual outcome, however, this needs to be reassessed in children presenting long after the injury.Treatment should still be recommended even for cases of delayed presentation to hospital.
Detterbeck, Andreas; Hofmeister, Michael; Hofmann, Elisabeth; Haddad, Daniel; Weber, Daniel; Hölzing, Astrid; Zabler, Simon; Schmid, Matthias; Hiller, Karl-Heinz; Jakob, Peter; Engel, Jens; Hiller, Jochen; Hirschfelder, Ursula
2016-07-01
To examine the relative usefulness and suitability of magnetic resonance imaging (MRI) in daily clinical practice as compared to various technologies of computed tomography (CT) in addressing questions of orthodontic interest. Three blinded raters evaluated 2D slices and 3D reconstructions created from scans of two pig heads. Five imaging modalities were used, including three CT technologies-multislice (MSCT), cone-beam CT (CBCT), and industrial (µCT)-and two MRI protocols with different scan durations. Defined orthodontic parameters were rated one by one on the 2D slices and the 3D reconstructions, followed by final overall ratings for each modality. A mixed linear model was used for statistical analysis. Based on the 2D slices, the parameter of visualizing tooth-germ topography did not yield any significantly different ratings for MRI versus any of the CT scans. While some ratings for the other parameters did involve significant differences, how these should be interpreted depends greatly on the relevance of each parameter. Based on the 3D reconstructions, the only significant difference between technologies was noted for the parameter of visualizing root-surface morphology. Based on the final overall ratings, the imaging performance of the standard MRI protocol was noninferior to the performance of the three CT technologies. On comparing the imaging performance of MRI and CT scans, it becomes clear that MRI has a huge potential for applications in daily clinical practice. Given its additional benefits of a good contrast ratio and complete absence of ionizing radiation, further studies are needed to explore this clinical potential in greater detail.
Long-term control of CMV retinitis in a patient with idiopathic CD4+ T lymphocytopenia.
Yashiro, Shigeko; Fujino, Yujiro; Tachikawa, Natsuo; Inamochi, Kazuya; Oka, Shinichi
2013-04-01
Cytomegalovirus (CMV) retinitis with idiopathic CD4(+) T lymphocytopenia (ICL) is rare and difficult to control. We report a first case for long-term control of CMV retinitis with ICL using interleukin-2 (IL-2) therapy and succeeded in discontinuation of anti-CMV therapy. A 49-year-old Japanese woman was diagnosed with ICL based on low CD4(+) count (72/μl), negative for HIV-1 and -2 antibodies, and absence of any defined immunodeficiency diseases or immunosuppressive therapy. PCR test of the aqueous humor in the right eye was suggestive of CMV retinitis. She was treated with systemic ganciclovir, but after several relapses of CMV retinitis, rhegmatogenous retinal detachment appeared in the right eye and she became blind in that eye. Three years later, she developed CMV retinitis in the left eye. Although she received systemic and focal anti-CMV treatments, the retinitis showed no improvement. Finally, retinal detachment occurred, and she underwent vitrectomy. IL-2 was injected to increase CD4(+) counts. Because of hyperpyrexia, blepharedema, central scotoma, and color anomaly, we changed to low-dose IL-2 therapy with no side effects. Finally, we succeeded in increasing the CD4(+) count to more than 200/μl after discontinuation of low-dose IL-2 therapy. CMV retinitis never recurred after discontinuation of anti-CMV therapy, with good visual acuity of 20/20 in the left eye. She developed blindness of the first affected right eye, whereas the visual acuity of the left eye remains excellent more than 12 years after the onset of CMV retinitis through the combined use of anti-CMV therapy, IL-2 therapy, and vitrectomy.
Population pharmacodynamic modelling of midazolam induced sedation in terminally ill adult patients
de Winter, Brenda C. M.; Masman, Anniek D.; van Dijk, Monique; Baar, Frans P. M.; Tibboel, Dick; Koch, Birgit C. P.; van Gelder, Teun; Mathot, Ron A. A.
2017-01-01
Aims Midazolam is the drug of choice for palliative sedation and is titrated to achieve the desired level of sedation. A previous pharmacokinetic (PK) study showed that variability between patients could be partly explained by renal function and inflammatory status. The goal of this study was to combine this PK information with pharmacodynamic (PD) data, to evaluate the variability in response to midazolam and to find clinically relevant covariates that may predict PD response. Method A population PD analysis using nonlinear mixed effect models was performed with data from 43 terminally ill patients. PK profiles were predicted by a previously described PK model and depth of sedation was measured using the Ramsay sedation score. Patient and disease characteristics were evaluated as possible covariates. The final model was evaluated using a visual predictive check. Results The effect of midazolam on the sedation level was best described by a differential odds model including a baseline probability, Emax model and interindividual variability on the overall effect. The EC50 value was 68.7 μg l–1 for a Ramsay score of 3–5 and 117.1 μg l–1 for a Ramsay score of 6. Comedication with haloperidol was the only significant covariate. The visual predictive check of the final model showed good model predictability. Conclusion We were able to describe the clinical response to midazolam accurately. As expected, there was large variability in response to midazolam. The use of haloperidol was associated with a lower probability of sedation. This may be a result of confounding by indication, as haloperidol was used to treat delirium, and deliria has been linked to a more difficult sedation procedure. PMID:28960387
Diagnosis and treatment of chronic lateral ankle instability with ligamentum bifurcatum injury
Sun, Yaning; Wang, Huijuan; Tang, Yuchao; Qin, Shiji; Zhao, Mingming; Zhang, Fengqi
2018-01-01
Abstract This study aimed to report our institution's experience in the diagnosis and treatment of chronic lateral ankle instability (CLAI) with ligamentum bifurcatum (LB) injury. This retrospective study included 218 consecutive patients with CLAI who underwent surgery from January 2012 to December 2015. The 218 patients received tendon allograft reconstruction of the lateral ligament. CLAI was combined with LB injury in 51.4% (112/218) of patients. The 112 patients with concurrent LB injury had this treated simultaneously; 36 patients underwent excision of the anterior process of the calcaneus, 68 underwent LB repair, and 8 underwent LB reconstruction. Patients returned for a clinical and radiologic follow-up evaluation at an average of 31 (range, 24–35) months postoperatively. Outcomes were assessed by comparison of pre- and postoperative American Orthopaedic Foot and Ankle Society (AOFAS) scores, visual analog scale pain scores, Karlsson scores, and radiographic assessment. Of the patients with concurrent LB injury, 82.1% (92/112) returned for final evaluation. Postoperatively, most patients recovered very well. However, the outcome was not ideal in those who underwent excision of the anterior process of the calcaneus; there were significant postoperative decreases in talar tilt (P < .05) and anterior drawer (P < .05), but there was no significant postoperative improvement in visual analog scale pain score and AOFAS score. Patients who underwent LB repair or reconstruction had an excellent or good outcome regarding patient subjective self-assessment, pain scores, Karlsson scores, and AOFAS scores at final follow-up. Patients with CLAI often have concurrent LB injury. The diagnosis of LB injury can be missed or delayed. Clinicians should closely examine the LB in cases of CLAI, and should surgically repair or reconstruct the LB when necessary. PMID:29489650
Lin, Ying; Liang, Xuanwei; Liu, Xialin; Qu, Bo; Ni, Yao; Jiang, Shuhong; Liu, Yizhi
2012-01-01
The aim of this study was to evaluate the clinical features and the visual results of fireworks-related ocular burn injuries and to determine the prognostic factors. The authors conducted a prospective observational study of 53 eyes of 46 consecutive patients with fireworks-related ocular injury who visited Zhongshan Ophthalmic Center during the Spring Festival in Southern China. Eyes were graded using an ocular trauma classification system, which included age of the patient. Patients were followed up for a minimum of 5 months. Best-corrected visual acuity at the last follow-up was considered the final visual outcome. Data were analyzed with SPSS version 13.0 (SPSS, Inc., Chicago, IL). Results of statistical tests were considered statistically significant for P < .05. Almost all patients (89.1%) were male with a mean age of 14.3 ± 8.5 years. There was preponderance of young patients, with 63.0% (29) of the patients being younger than 15 years. In addition to their ocular injuries, 23 patients (50.0%) also had eyelid and/or facial burns. The most common initial anterior segment injuries were open-globe injuries (42, 79.3%), conjunctival burns (16, 30.2%), and foreign bodies (18, 34.0%). Others were traumatic cataract, lens subluxation and dislocation, and vitreous hemorrhage. Management after first aid included pars plana vitrectomy (9, 17.0%), aspiration of cataract (18, 34.0%), retinal reattachment (8, 15.1%), and enucleation. Amniotic membrane grafts were used in 11 patients (20.8%) with serious conjunctiva burns and corneal contusions and abrasions who were thought to have a good prognosis. Fireworks-related ocular injuries included a variety of clinical manifestations. Examinations such as B scan, optical coherence tomography, and ultrasound biomicroscopy helped to make a correct diagnosis and plan further treatment. Fireworks-related ocular injuries commonly affect young male subjects of Southern China. Visual outcomes were frequently poor and visually devastating. Laws should be passed to forbid the personal use of fireworks in China, and public education on the sale and use of fireworks should be increased.
A visual metaphor describing neural dynamics in schizophrenia.
van Beveren, Nico J M; de Haan, Lieuwe
2008-07-09
In many scientific disciplines the use of a metaphor as an heuristic aid is not uncommon. A well known example in somatic medicine is the 'defense army metaphor' used to characterize the immune system. In fact, probably a large part of the everyday work of doctors consists of 'translating' scientific and clinical information (i.e. causes of disease, percentage of success versus risk of side-effects) into information tailored to the needs and capacities of the individual patient. The ability to do so in an effective way is at least partly what makes a clinician a good communicator. Schizophrenia is a severe psychiatric disorder which affects approximately 1% of the population. Over the last two decades a large amount of molecular-biological, imaging and genetic data have been accumulated regarding the biological underpinnings of schizophrenia. However, it remains difficult to understand how the characteristic symptoms of schizophrenia such as hallucinations and delusions are related to disturbances on the molecular-biological level. In general, psychiatry seems to lack a conceptual framework with sufficient explanatory power to link the mental- and molecular-biological domains. Here, we present an essay-like study in which we propose to use visualized concepts stemming from the theory on dynamical complex systems as a 'visual metaphor' to bridge the mental- and molecular-biological domains in schizophrenia. We first describe a computer model of neural information processing; we show how the information processing in this model can be visualized, using concepts from the theory on complex systems. We then describe two computer models which have been used to investigate the primary theory on schizophrenia, the neurodevelopmental model, and show how disturbed information processing in these two computer models can be presented in terms of the visual metaphor previously described. Finally, we describe the effects of dopamine neuromodulation, of which disturbances have been frequently described in schizophrenia, in terms of the same visualized metaphor. The conceptual framework and metaphor described offers a heuristic tool to understand the relationship between the mental- and molecular-biological domains in an intuitive way. The concepts we present may serve to facilitate communication between researchers, clinicians and patients.
Quinoxaline-based inhibitors of Ebola and Marburg VP40 egress.
Loughran, H Marie; Han, Ziying; Wrobel, Jay E; Decker, Sarah E; Ruthel, Gordon; Freedman, Bruce D; Harty, Ronald N; Reitz, Allen B
2016-08-01
We prepared a series of quinoxalin-2-mercapto-acetyl-urea analogs and evaluated them for their ability to inhibit viral egress in our Marburg and Ebola VP40 VLP budding assays in HEK293T cells. We also evaluated selected compounds in our bimolecular complementation assay (BiMC) to detect and visualize a Marburg mVP40-Nedd4 interaction in live mammalian cells. Antiviral activity was assessed for selected compounds using a live recombinant vesicular stomatitis virus (VSV) (M40 virus) that expresses the EBOV VP40 PPxY L-domain. Finally selected compounds were evaluated in several ADME assays to have an early assessment of their drug properties. Our compounds had low nM potency in these assays (e.g., compounds 21, 24, 26, 39), and had good human liver microsome stability, as well as little or no inhibition of P450 3A4. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ju, Bo; Wang, Yi; Zhang, Yu-Mo; Zhang, Ting; Liu, Zhihe; Li, Minjie; Xiao-An Zhang, Sean
2018-04-18
Advances in the development of fluorescent carbon dots (CDs) for detecting nitro-explosives have attracted great interest. However, developing long-wavelength luminescence CDs for highly selective determination of 2,4,6-trinitrophenol (TNP) and getting insight into the detection mechanism remain further to be investigated. Here, excitation-independent yellow-green emission CDs with good photostability and low biotoxicity were introduced for detecting TNP selectively. Then, two types of electron transfer (ET) processes including hydrogen-bond interaction-assisted ET and proton transfer-assisted ET are suggested to be responsible for their photophysical behavior. Finally, the visual detection of TNP has been successfully developed by a CD-based indicator paper. The facile, highly sensitive, and selective detection for TNP in both of a solution and a solid phase makes CDs potentially useful in environmental sensor applications.
Application of GIS to modified models of vehicle emission dispersion
NASA Astrophysics Data System (ADS)
Jin, Taosheng; Fu, Lixin
This paper reports on a preliminary study of the forecast and evaluation of transport-related air pollution dispersion in urban areas. Some modifications of the traditional Gauss dispersion models are provided, and especially a crossroad model is built, which considers the great variation of vehicle emission attributed to different driving patterns at the crossroad. The above models are combined with a self-developed geographic information system (GIS) platform, and a simulative system with graphical interfaces is built. The system aims at visually describing the influences on the urban environment by urban traffic characteristics and therefore gives a reference to the improvement of urban air quality. Due to the introduction of a self-developed GIS platform and a creative crossroad model, the system is more effective, flexible and accurate. Finally, a comparison of the simulated (predicted) and observed hourly concentration is given, which indicates a good simulation.
FINAL ECOSYSTEM GOODS AND SERVICES CLASSIFICATION SYSTEM (FEGS-CS)
This document defines and classifies 338 Final Ecosystem Goods and Services (FEGS), each defined and uniquely numbered by a combination of environmental class or sub-class and a beneficiary category or sub-category. The introductory section provides the rationale and conceptual ...
Visualizing Geographic Data in Google Earth for Education and Outreach
NASA Astrophysics Data System (ADS)
Martin, D. J.; Treves, R.
2008-12-01
Google Earth is an excellent tool to help students and the public visualize scientific data as with low technical skill scientific content can be shown in three dimensions against a background of remotely sensed imagery. It therefore has a variety of uses in university education and as a tool for public outreach. However, in both situations it is of limited value if it is only used to attract attention with flashy three dimensional animations. In this poster we shall illustrate several applications that represent what we believe is good educational practice. The first example shows how the combination of a floor map and a projection of Google Earth on a screen can be used to produce active learning. Students are asked to imagine where they would build a house on Big Island Hawaii in order to avoid volcanic hazards. In the second example Google Earth is used to illustrate evidence over a range of scales in a description of Lake Agassiz flood events which would be more difficult to comprehend in a traditional paper based format. In the final example a simple text manipulation application "TMapper" is used to change the color palette of a thematic map generated by the students in Google Earth to teach them about the use of color in map design.
NASA Astrophysics Data System (ADS)
Meitzler, Thomas J.
The field of computer vision interacts with fields such as psychology, vision research, machine vision, psychophysics, mathematics, physics, and computer science. The focus of this thesis is new algorithms and methods for the computation of the probability of detection (Pd) of a target in a cluttered scene. The scene can be either a natural visual scene such as one sees with the naked eye (visual), or, a scene displayed on a monitor with the help of infrared sensors. The relative clutter and the temperature difference between the target and background (DeltaT) are defined and then used to calculate a relative signal -to-clutter ratio (SCR) from which the Pd is calculated for a target in a cluttered scene. It is shown how this definition can include many previous definitions of clutter and (DeltaT). Next, fuzzy and neural -fuzzy techniques are used to calculate the Pd and it is shown how these methods can give results that have a good correlation with experiment. The experimental design for actually measuring the Pd of a target by observers is described. Finally, wavelets are applied to the calculation of clutter and it is shown how this new definition of clutter based on wavelets can be used to compute the Pd of a target.
NASA Astrophysics Data System (ADS)
Del Lama, L. S.; Cunha, D. M.; Poletti, M. E.
2017-08-01
The presence and morphology of microcalcification clusters are the main point to provide early indications of breast carcinomas. However, the visualization of those structures may be jeopardized due to overlapping tissues even for digital mammography systems. Although digital mammography is the current standard for breast cancer diagnosis, further improvements should be achieved in order to address some of those physical limitations. One possible solution for such issues is the application of the dual-energy technique (DE), which is able to highlight specific lesions or cancel out the tissue background. In this sense, this work aimed to evaluate several quantities of interest in radiation applications and compare those values with works present in the literature to validate a modified PENELOPE code for digital mammography applications. For instance, the scatter-to-primary ratio (SPR), the scatter fraction (SF) and the normalized mean glandular dose (DgN) were evaluated by simulations and the resulting values were compared to those found in earlier studies. Our results present a good correlation for the evaluated quantities, showing agreement equal or better than 5% for the scatter and dosimetric-related quantities when compared to the literature. Finally, a DE imaging chain was simulated and the visualization of microcalcifications was investigated.
The Effect of Radiation on Selected Photographic Film
NASA Technical Reports Server (NTRS)
Slater, Richard; Kinard, John; Firsov, Ivan
2000-01-01
We conducted this film test to evaluate several manufacturers' photographic films for their ability to acquire imagery on the International Space Station. We selected 25 motion picture, photographic slide, and negative films from three different film manufacturers. We based this selection on the fact that their films ranked highest in other similar film tests, and on their general acceptance by the international community. This test differed from previous tests because the entire evaluation process leading up to the final selection was based on information derived after the original flight film was scanned to a digital file. Previously conducted tests were evaluated entirely based on 8 x 10s that were produced from the film either directly or through the internegative process. This new evaluation procedure provided accurate quantitative data on granularity and contrast from the digital data. This test did not try to define which film was best visually. This is too often based on personal preference. However, the test results did group the films by good, marginal, and unacceptable. We developed, and included in this report, a template containing quantitative, graphical, and visual information for each film. These templates should be sufficient for comparing the different films tested and subsequently selecting a film or films to be used for experiments and general documentation on the International Space Station.
Optoelectronic retinal prosthesis: system design and performance
NASA Astrophysics Data System (ADS)
Loudin, J. D.; Simanovskii, D. M.; Vijayraghavan, K.; Sramek, C. K.; Butterwick, A. F.; Huie, P.; McLean, G. Y.; Palanker, D. V.
2007-03-01
The design of high-resolution retinal prostheses presents many unique engineering and biological challenges. Ever smaller electrodes must inject enough charge to stimulate nerve cells, within electrochemically safe voltage limits. Stimulation sites should be placed within an electrode diameter from the target cells to prevent 'blurring' and minimize current. Signals must be delivered wirelessly from an external source to a large number of electrodes, and visual information should, ideally, maintain its natural link to eye movements. Finally, a good system must have a wide range of stimulation currents, external control of image processing and the option of either anodic-first or cathodic-first pulses. This paper discusses these challenges and presents solutions to them for a system based on a photodiode array implant. Video frames are processed and imaged onto the retinal implant by a head-mounted near-to-eye projection system operating at near-infrared wavelengths. Photodiodes convert light into pulsed electric current, with charge injection maximized by applying a common biphasic bias waveform. The resulting prosthesis will provide stimulation with a frame rate of up to 50 Hz in a central 10° visual field, with a full 30° field accessible via eye movements. Pixel sizes are scalable from 100 to 25 µm, corresponding to 640-10 000 pixels on an implant 3 mm in diameter.
Bilateral ring-shaped intrastromal opacities after corneal cross-linking for keratoconus.
Camesasca, Fabrizio I; Vinciguerra, Paolo; Seiler, Theo
2011-12-01
To report a case of bilateral, ring-shaped, intrastromal corneal opacities after corneal cross-linking (CXL) for progressive keratoconus. A 21-year-old man with bilateral, progressive keratoconus underwent CXL with riboflavin 0.1% and ultraviolet A (UVA) light in the right eye and, 6 months later, in the left eye. One day after CXL, the right eye showed a sharply demarcated white ring in the corneal periphery. The ring involved the superficial stroma at 2 mm from the limbus, extended from 1 to 11 o'clock, and was 1.5-mm wide. Corneal topography showed marked central flattening. Six months after treatment, a residual, faint, ring-shaped opacity remained, with a decrease in corneal ectasia. Cross-linking was then performed in the left eye. Different ultraviolet devices were used in the two eyes. On postoperative day 1, the left eye also showed a white ring of stromal opacity. Scheimpflug imaging showed corneal stromal contraction in the zone of whitening. At final examination, >1 year after surgery, corrected visual acuity was 0.00 logMAR with cylinder of 2.00 diopters in both eyes. The bilateral intrastromal corneal changes were innocuous in the long-term, with preservation of good visual acuity and successful stabilization of progressive keratoconus.
Effects of Motion and Figural Goodness on Haptic Object Perception in Infancy.
ERIC Educational Resources Information Center
Streri, Arlette; Spelke, Elizabeth S.
1989-01-01
After haptic habituation to a ring display, infants perceived the rings in two experiments as parts of one connected object. In both haptic and visual modes, infants appeared to perceive object unity by analyzing motion but not by analyzing figural goodness. (RH)
Intellectual Abilities That Discriminate Good and Poor Problem Solvers.
ERIC Educational Resources Information Center
Meyer, Ruth Ann
1981-01-01
This study compared good and poor fourth-grade problem solvers on a battery of 19 "reference" tests for verbal, induction, numerical, word fluency, memory, perceptual speed, and simple visualization abilities. Results suggest verbal, numerical, and especially induction abilities are important to successful mathematical problem solving.…
Young children's coding and storage of visual and verbal material.
Perlmutter, M; Myers, N A
1975-03-01
36 preschool children (mean age 4.2 years) were each tested on 3 recognition memory lists differing in test mode (visual only, verbal only, combined visual-verbal). For one-third of the children, original list presentation was visual only, for another third, presentation was verbal only, and the final third received combined visual-verbal presentation. The subjects generally performed at a high level of correct responding. Verbal-only presentation resulted in less correct recognition than did either visual-only or combined visual-verbal presentation. However, because performances under both visual-only and combined visual-verbal presentation were statistically comparable, and a high level of spontaneous labeling was observed when items were presented only visually, a dual-processing conceptualization of memory in 4-year-olds was suggested.
NASA Technical Reports Server (NTRS)
Schmidt, Gordon S.; Mueller, Thomas J.
1987-01-01
The use of flow visualization to study separation bubbles is evaluated. The wind tunnel, two NACA 66(3)-018 airfoil models, and kerosene vapor, titanium tetrachloride, and surface flow visualizations techniques are described. The application of the three visualization techniques to the two airfoil models reveals that the smoke and vapor techniques provide data on the location of laminar separation and the onset of transition, and the surface method produces information about the location of turbulent boundary layer separation. The data obtained with the three flow visualization techniques are compared to pressure distribution data and good correlation is detected. It is noted that flow visualization is an effective technique for examining separation bubbles.
Iu, Lawrence P; Fan, Michelle C; Lau, Jordy K; Chan, Thomas S; Kwong, Yok-Lam; Wong, Ian Y
2016-05-01
To evaluate clinical features and long-term visual outcome of cytomegalovirus (CMV) retinitis in patients without human immunodeficiency virus (HIV) infection, and to determine factors that predict visual outcome. Retrospective cohort study. Consecutive patients with CMV retinitis without HIV infection were reviewed. Main outcome measures included clinical features, proportion of eyes with 6-month and final visual acuity (VA) <20/70 and <20/400, and odds ratios of factors associated with poor visual outcome. A total of 20 eyes from 13 patients were included with a median follow-up time of 17 months. All had at least 6 months of follow-up except 1 patient who died from sepsis at 1 month. At presentation, 50% of eyes had VA <20/70 and 25% had VA <20/400. Zone 1 involvement occurred in 55% and vitreous haze ≥grade 2+ occurred in 25%. Recurrence occurred in 33.3% at a mean time of 6.4 ± 3.3 weeks after discontinuation of anti-CMV therapy. The retinal detachment rate was 21.7% per eye-year and mortality rate was 11.7% per person-year. At final visit, 60% had VA <20/70 and 35% had VA <20/400. Macular involvement was significantly associated with poor final VA <20/400 (odds ratio = 25.00, P = .016). CMV retinitis without HIV infection was often aggressive at presentation. Significant intraocular inflammation was not uncommon. The long-term visual outcome was poor, especially in those with macular involvement. Copyright © 2016 Elsevier Inc. All rights reserved.
Nonlinear projection methods for visualizing Barcode data and application on two data sets.
Olteanu, Madalina; Nicolas, Violaine; Schaeffer, Brigitte; Denys, Christiane; Missoup, Alain-Didier; Kennis, Jan; Larédo, Catherine
2013-11-01
Developing tools for visualizing DNA sequences is an important issue in the Barcoding context. Visualizing Barcode data can be put in a purely statistical context, unsupervised learning. Clustering methods combined with projection methods have two closely linked objectives, visualizing and finding structure in the data. Multidimensional scaling (MDS) and Self-organizing maps (SOM) are unsupervised statistical tools for data visualization. Both algorithms map data onto a lower dimensional manifold: MDS looks for a projection that best preserves pairwise distances while SOM preserves the topology of the data. Both algorithms were initially developed for Euclidean data and the conditions necessary to their good implementation were not satisfied for Barcode data. We developed a workflow consisting in four steps: collapse data into distinct sequences; compute a dissimilarity matrix; run a modified version of SOM for dissimilarity matrices to structure the data and reduce dimensionality; project the results using MDS. This methodology was applied to Astraptes fulgerator and Hylomyscus, an African rodent with debated taxonomy. We obtained very good results for both data sets. The results were robust against unbalanced species. All the species in Astraptes were well displayed in very distinct groups in the various visualizations, except for LOHAMP and FABOV that were mixed up. For Hylomyscus, our findings were consistent with known species, confirmed the existence of four unnamed taxa and suggested the existence of potentially new species. © 2013 John Wiley & Sons Ltd.
Pavlides, Michael; Birks, Jacqueline; Fryer, Eve; Delaney, David; Sarania, Nikita; Banerjee, Rajarshi; Neubauer, Stefan; Barnes, Eleanor; Fleming, Kenneth A; Wang, Lai Mun
2017-04-01
The aim of the study was to investigate the interobserver agreement for categorical and quantitative scores of liver fibrosis. Sixty-five consecutive biopsy specimens from patients with mixed liver disease etiologies were assessed by three pathologists using the Ishak and nonalcoholic steatohepatitis Clinical Research Network (NASH CRN) scoring systems, and the fibrosis area (collagen proportionate area [CPA]) was estimated by visual inspection (visual-CPA). A subset of 20 biopsy specimens was analyzed using digital imaging analysis (DIA) for the measurement of CPA (DIA-CPA). The bivariate weighted κ between any two pathologists ranged from 0.57 to 0.67 for Ishak staging and from 0.47 to 0.57 for the NASH CRN staging. Bland-Altman analysis showed poor agreement between all possible pathologist pairings for visual-CPA but good agreement between all pathologist pairings for DIA-CPA. There was good agreement between the two pathologists who assessed biopsy specimens by visual-CPA and DIA-CPA. The intraclass correlation coefficient, which is equivalent to the κ statistic for continuous variables, was 0.78 for visual-CPA and 0.97 for DIA-CPA. These results suggest that DIA-CPA is the most robust method for assessing liver fibrosis followed by visual-CPA. Categorical scores perform less well than both the quantitative CPA scores assessed here. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Giuliano, Vincenzo; Giuliano, Concetta; Pinto, Fabio; Scaglione, Mariano
2005-07-01
The purpose of this study is to determine if focused CT examinations of the pelvis, utilizing fixed oral dosage of diatrizoate contrast media, improve overall reader confidence in visualization of the appendix. Five hundred and twenty-five patients referred for, rule out appendicitis, evaluations underwent focused CT examinations of the pelvis following fixed oral dosage of diatrizoate contrast media. A five-point scale was used to assess the effect of contrast enhancement of the distal small bowel, cecum, and appendix on overall reader confidence, and subsequent visualization of the appendix. Bowel preparation was ideal in 504 of 525 (96%) patients. Enhanced supine CT images following oral administration of fixed dosage of diatrizoate had consistently good scores for reader confidence for bowel opacification (4.8+/-0.1, P<0.005) and visualization of the appendix (3.7+/-0.1, P<0.005), at 50 min following oral contrast administration. This method improved visualization of the normal appendix in 446 of 504 (88%) patients, with a specificity of 99%. In a patients meeting CT criteria for appendicitis, 21 of 21 (100%) patients were proven at surgery. The use of fixed oral dosage of diatrizoate contrast media resulted in good overall reader confidence to visualize the appendix and peri-appendiceal area, in addition to high specificity and rapid transit time.
Khan, Momna; Sultana, Syeda Seema; Jabeen, Nigar; Arain, Uzma; Khans, Salma
2015-02-01
To determine the diagnostic accuracy of visual inspection of cervix using 3% acetic acid as a screening test for early detection of cervical cancer taking histopathology as the gold standard. The cross-sectional study was conducted at Civil Hospital Karachi from July 1 to December 31, 2012 and comprised all sexually active women aged 19-60 years. During speculum examination 3% acetic acid was applied over the cervix with the help of cotton swab. The observations were noted as positive or negative on visual inspection of the cervix after acetic acid application according to acetowhite changes. Colposcopy-guided cervical biopsy was done in patients with positive or abnormal looking cervix. Colposcopic-directed biopsy was taken as the gold standard to assess visual inspection readings. SPSS 17 was used for statistical analysis. There were 500 subjects with a mean age of 35.74 ± 9.64 years. Sensitivity, specifically, positive predicted value, negative predicted value of visual inspection of the cervix after acetic acid application was 93.5%, 95.8%, 76.3%, 99%, and the diagnostic accuracy was 95.6%. Visual inspection of the cervix after acetic acid application is an effective method of detecting pre-invasive phase of cervical cancer and a good alternative to cytological screening for cervical cancer in resource-poor setting like Pakistan and can reduce maternal morbidity and mortality.
The Effects of Brain Damage on Visual Functioning in Children.
ERIC Educational Resources Information Center
Alexander, P. K.
1990-01-01
The review of research concluded that, although brain damage affects visual functioning, the prognosis for good functional vision after remedial intervention is better than previously thought. Although electrodiagnostic testing was found to be valuable, use of a combination of tests is recommended to obtain the most complete picture of brain…
Technical Considerations in the Delivery of Audio-Visual Course Content.
ERIC Educational Resources Information Center
Lightfoot, Jay M.
2002-01-01
In an attempt to provide students with the benefit of the latest technology, some instructors include multimedia content on their class Web sites. This article introduces the basic terms and concepts needed to understand the multimedia domain. Provides a brief tutorial designed to help instructors create good, consistent audio-visual content. (AEF)
Visual Recognition Memory, Paired-Associate Learning, and Reading Achievement.
ERIC Educational Resources Information Center
Anderson, Roger H.; Samuels, S. Jay
The relationship between visual recognition memory and performance on a paired-associate task for good and poor readers was investigated. Subjects were three groups of 21, 21, and 22 children each, with mean IQ's of 98.2, 108.1, and 118.0, respectively. Three experimental tasks, individually administered to each subject, measured visual…
Hazardous sign detection for safety applications in traffic monitoring
NASA Astrophysics Data System (ADS)
Benesova, Wanda; Kottman, Michal; Sidla, Oliver
2012-01-01
The transportation of hazardous goods in public streets systems can pose severe safety threats in case of accidents. One of the solutions for these problems is an automatic detection and registration of vehicles which are marked with dangerous goods signs. We present a prototype system which can detect a trained set of signs in high resolution images under real-world conditions. This paper compares two different methods for the detection: bag of visual words (BoW) procedure and our approach presented as pairs of visual words with Hough voting. The results of an extended series of experiments are provided in this paper. The experiments show that the size of visual vocabulary is crucial and can significantly affect the recognition success rate. Different code-book sizes have been evaluated for this detection task. The best result of the first method BoW was 67% successfully recognized hazardous signs, whereas the second method proposed in this paper - pairs of visual words and Hough voting - reached 94% of correctly detected signs. The experiments are designed to verify the usability of the two proposed approaches in a real-world scenario.
Hubble Goes IMAX: 3D Visualization of the GOODS Southern Field for a Large Format Short Film
NASA Astrophysics Data System (ADS)
Summers, F. J.; Stoke, J. M.; Albert, L. J.; Bacon, G. T.; Barranger, C. L.; Feild, A. R.; Frattare, L. M.; Godfrey, J. P.; Levay, Z. G.; Preston, B. S.; Fletcher, L. M.; GOODS Team
2003-12-01
The Office of Public Outreach at the Space Telescope Science Institute is producing a several minute IMAX film that will have its world premiere at the January 2004 AAS meeting. The film explores the rich tapestry of galaxies in the GOODS Survey Southern Field in both two and three dimensions. This poster describes the visualization efforts from FITS files through the galaxy processing pipeline to 3D modelling and the rendering of approximately 100 billion pixels. The IMAX film will be shown at a special session at Fernbank Science Center, and the video will be shown at the STScI booth.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-17
... Procedure Act (APA), 5 U.S.C. 553(b)(B), provides that, when an agency for good cause finds that notice and... (A) or (B) of section 553(b) of the APA. Specifically, EPA is correcting the final rule to indicate... omitted from the final rule. EPA also finds that there is good cause under APA section 553(d)(3) for these...
Ebert, Kristin M; Hewitt, Geri D; Indyk, Justin A; McCracken, Katherine A; Nahata, Leena; Jayanthi, Venkata R
2018-04-01
Patients with gonadal dysgenesis (GD) with a Y chromosome have an increased risk of gonadal neoplasm. Few data exist on the ability of imaging to detect malignancy in intra-abdominal gonads in these patients. We aimed to determine the correlation between preoperative imaging findings and gonadal pathology in GD patients with Y chromosome material. A retrospective review was performed of patients with XY or XO/XY GD who underwent gonadectomy at our institution from 2003 to 2017. Patients were assessed preoperatively with ultrasonography; some additionally underwent MRI. The series consisted of 10 patients, all with female gender and non-palpable gonads. Median age was 13.1 years (range 2.4-18.3 years). Overall, four of the ten patients (40%) had a tumor (gonadoblastoma or dysgerminoma) on final pathology. Four patients had a gonad or gonads that were definitively seen on ultrasonography. All visualized gonads were described as "normal" or "small" with the exception of one patient, who had a normal MRI. Three of the four patients in this group had a tumor on final pathology. The remaining six patients had a gonad or gonads that were not definitively visualized on ultrasound; one patient in this group had a tumor on final pathology. Overall, five of seven gonads (71%) definitively visualized on ultrasound had tumor on final pathology, and two of thirteen gonads (15%) not visualized on ultrasound had tumor on final pathology; this difference was statistically significant (p = 0.012). Three patients were imaged with MRI. Of the gonads that could be visualized on MRI, no definitive abnormalities were seen. All patients imaged with MRI had tumors on final pathology. Both ultrasound and MRI are relatively poor at identifying and characterizing intra-abdominal gonads in GD patients. The majority of patients who had a neoplasm had normal imaging findings. Gonads that were definitively visualized on ultrasound were more likely to contain neoplasms that could not be visualized, which perhaps because of tumor growth. No other consistent imaging findings of malignancy were found. Our study included ultrasound evaluations that were completed over 10 years ago and not performed by pediatric ultrasonographers, which may have biased the results. However, results suggest that when discussing gonadectomy with GD patients, one should not be reassured by "normal" imaging findings. Neither ultrasound nor MRI should be relied on for surveillance in GD patients who decide against gonadectomy. A normal ultrasound or MRI does not rule out neoplasm in GD patients with intra-abdominal gonads. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Functional visual fields: relationship of visual field areas to self-reported function.
Subhi, Hikmat; Latham, Keziah; Myint, Joy; Crossland, Michael D
2017-07-01
The aim of this study is to relate areas of the visual field to functional difficulties to inform the development of a binocular visual field assessment that can reflect the functional consequences of visual field loss. Fifty-two participants with peripheral visual field loss undertook binocular assessment of visual fields using the 30-2 and 60-4 SITA Fast programs on the Humphrey Field Analyser, and mean thresholds were derived. Binocular visual acuity, contrast sensitivity and near reading performance were also determined. Self-reported overall and mobility function were assessed using the Dutch ICF Activity Inventory. Greater visual field loss (0-60°) was associated with worse self-reported function both overall (R 2 = 0.50; p < 0.0001), and for mobility (R 2 = 0.64; p < 0.0001). Central (0-30°) and peripheral (30-60°) visual field areas were similarly related to mobility function (R 2 = 0.61, p < 0.0001 and R 2 = 0.63, p < 0.0001 respectively), although the peripheral (30-60°) visual field was the best predictor of mobility self-reported function in multiple regression analyses. Superior and inferior visual field areas related similarly to mobility function (R 2 = 0.56, p < 0.0001 and R 2 = 0.67, p < 0.0001 respectively). The inferior field was found to be the best predictor of mobility function in multiple regression analysis. Mean threshold of the binocular visual field to 60° eccentricity is a good predictor of self-reported function overall, and particularly of mobility function. Both the central (0-30°) and peripheral (30-60°) mean threshold are good predictors of self-reported function, but the peripheral (30-0°) field is a slightly better predictor of mobility function, and should not be ignored when considering functional consequences of field loss. The inferior visual field is a slightly stronger predictor of perceived overall and mobility function than the superior field. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.
Kwon, Soon Il; Lee, Jung Pil; Park, Sung Pyo; Lee, Eun Kyung; Huh, Sun; Park, In Won
2011-03-01
To analyze the characteristics and clinical manifestations of clinically diagnosed and serologically confirmed ocular toxocariasis in patients. Thirty-three eyes of 33 patients diagnosed as having ocular toxocariasis at the Hallym University Medical Center between January 1999 and December 2008 were included in the study. The diagnosis of ocular toxocariasis was based on clinical features and confirmed serologically by enzyme-linked immunosorbent assay and immunoblotting. All patients were interviewed by using a structured questionnaire that included risk factors that might account for the introduction of Toxocara larvae. Demographics, social characteristics determined from the questionnaire, and clinical features were evaluated. A total of 33 eyes of 33 patients were enrolled in this study: 24 (73%) patients were men, and mean patient age was 41.6 ± 11.0 years. Ten of 28 patients (36%) who responded to the questionnaire had a history of contact with pets, and 23 (82%) had a history of consuming raw food. The most common symptoms were blurred vision in 22 eyes (67%) and floaters in six eyes (18%). The toxocariasis was unilateral in all patients, and the inflammation was acute in two-thirds of the patients. In 17 eyes (52%), Toxocara granuloma was found in the peripheral retina. Nineteen eyes (58%) had visual acuity of 20/40 or better at presentation and improved significantly after treatment. Final visual acuity was 20/40 or better in 26 eyes (79%). Ocular toxocariasis in Korea usually affects young adults to middle-aged men. The clinical manifestation is unilateral and presents as acute inflammation with a peripheral inflammatory mass. Visual prognosis with appropriate treatment is good.
Optimal compliance for amblyopia therapy: occlusion with a translucent tape on the lens.
Beneish, Raquel G; Polomeno, Robert C; Flanders, Michael E; Koenekoop, Robert K
2009-10-01
To demonstrate that optimal compliance to amblyopia therapy and a better visual outcome can be achieved by occluding the lens over the preferred eye with a translucent tape. Prospective study of amblyopic children. Eighty-four amblyopic children recruited from 2000 to 2006 at the Montreal Children's Vision Centre. A group of bilateral ametropes (mean age 3.8 years) were treated with glasses and occlusion of the sound eye with a translucent tape on the lens over the preferred eye, or an adhesive patch. The translucent tape reduced vision to hand motion at 0.3 m in the sound eye. Patients were divided into 2 groups depending on the treatment received. Group 1 (n = 36) was occluded with a translucent tape, and group 2 (n = 48) with a conventional adhesive patch, later replaced by the translucent tape. Twenty-five previously reported patients, treated with the conventional adhesive patch only, were used as controls (group 3). The mean amblyopic visual acuity was 20/100-2. Compliance was good in 36 patients (group 1), and was poor or deteriorated in 24/48 patients (group 2). Substituting the adhesive patch with a translucent tape permitted uninterrupted and prolonged occlusion, with a successful visual outcome. The amblyopic eye achieved a significantly better final vision (20/30+2; groups 1+2) than the controls (20/40+1; group 3) (p = 0.04). Sixty-four (76.19%) patients achieved >or=20/30. The translucent tape optimizes compliance and yields better vision by lengthening the duration of occlusion therapy and reducing the number of treatment failures due to noncompliance.
12 CFR Appendix C to Part 707 - Official Staff Interpretations
Code of Federal Regulations, 2014 CFR
2014-01-01
... and Regulations. Good faith compliance with this commentary affords protection from liability under.... Advertisements include commercial messages in visual, oral, or print media that invite, offer, or otherwise..., “prospective rates” are rates set in good faith in advance of the close of a dividend period, that may be...
12 CFR Appendix C to Part 707 - Official Staff Interpretations
Code of Federal Regulations, 2013 CFR
2013-01-01
... and Regulations. Good faith compliance with this commentary affords protection from liability under.... Advertisements include commercial messages in visual, oral, or print media that invite, offer, or otherwise..., “prospective rates” are rates set in good faith in advance of the close of a dividend period, that may be...
The concept of Final Ecosystem Goods and Services (FEGS) explicitly connects ecosystem services to the people that benefit from them. This report presents a number of practical strategies for incorporating FEGS, and more broadly ecosystem services, into the decision-making proces...
Understanding how climate change will alter the availability of coastal final ecosystem goods and services (FEGS; such as food provisioning from fisheries, property protection, and recreation) has significant implications for coastal planning and the development of adaptive manag...
ERIC Educational Resources Information Center
Au, Kathryn H.
The oral reading errors of 15 second graders were analyzed to find out if strategies used by good and poor readers could be differentiated. Patterns of errors were identified, and it was found that good readers often used context cues, while poor readers relied heavily on visual-phonic information. It was also possible to identify good and poor…
Color extended visual cryptography using error diffusion.
Kang, InKoo; Arce, Gonzalo R; Lee, Heung-Kyu
2011-01-01
Color visual cryptography (VC) encrypts a color secret message into n color halftone image shares. Previous methods in the literature show good results for black and white or gray scale VC schemes, however, they are not sufficient to be applied directly to color shares due to different color structures. Some methods for color visual cryptography are not satisfactory in terms of producing either meaningless shares or meaningful shares with low visual quality, leading to suspicion of encryption. This paper introduces the concept of visual information pixel (VIP) synchronization and error diffusion to attain a color visual cryptography encryption method that produces meaningful color shares with high visual quality. VIP synchronization retains the positions of pixels carrying visual information of original images throughout the color channels and error diffusion generates shares pleasant to human eyes. Comparisons with previous approaches show the superior performance of the new method.
Wood, C M; Richardson, J
1990-01-01
Indirect choroidal ruptures result from blunt ocular trauma and have a pathognomonic fundal appearance. We analysed a group of 30 patients with indirect choroidal ruptures with specific reference to the circumstances of the injury, the pattern of ocular damage, the cause of any visual loss, and the final visual outcome. Using this analysis we deduce a pathogenetic explanation for the characteristic fundus signs in patients with indirect choroidal ruptures. The majority of cases were young males injured during sport or by an assault, a minority were injured at work. Diffuse nonfocal impact injuries due to punches were associated with ruptures concentric with and adjacent to the optic disc. Focal impact injuries, due to projectiles, showed more extensive ocular damage. Seventeen of 30 patients regained 6/12 vision after injury. Injuries due to projectiles and temporally situated ruptures were associated with a poorer visual outcome than others. Macular damage was the commonest cause of visual loss, principally due to pigmentary maculopathy, traumatic inner retinal damage, and choroidal neovascular membranes rather than direct focal damage by the rupture. Images PMID:2337545
DOT National Transportation Integrated Search
2005-01-01
This report presents the results of a project to finalize and apply a crawling robotic system for the remote visual inspection of high-mast light poles. The first part of the project focused on finalizing the prototype crawler robot hardware and cont...
The relationship between two visual communication systems: reading and lipreading.
Williams, A
1982-12-01
To explore the relationship between reading and lipreading and to determine whether readers and lipreaders use similar strategies to comprehend verbal messages, 60 female junior and sophomore high school students--30 good and 30 poor readers--were given a filmed lipreading test, a test to measure eye-voice span, a test of cloze ability, and a test of their ability to comprehend printed material presented one word at a time in the absence of an opportunity to regress or scan ahead. The results of this study indicated that (a) there is a significant relationship between reading and lipreading ability; (b) although good readers may be either good or poor lipreaders, poor readers are more likely to be poor than good lipreaders; (c) there are similarities in the strategies used by readers and lipreaders in their approach to comprehending spoken and written material; (d) word-by-word reading of continuous prose appears to be a salient characteristic of both poor reading and poor lipreading ability; and (c) good readers and lipreaders do not engage in word-by-word reading but rather use a combination of visual and linguistic cues to interpret written and spoken messages.
Kwon, Oh-Hyun; Crnovrsanin, Tarik; Ma, Kwan-Liu
2018-01-01
Using different methods for laying out a graph can lead to very different visual appearances, with which the viewer perceives different information. Selecting a "good" layout method is thus important for visualizing a graph. The selection can be highly subjective and dependent on the given task. A common approach to selecting a good layout is to use aesthetic criteria and visual inspection. However, fully calculating various layouts and their associated aesthetic metrics is computationally expensive. In this paper, we present a machine learning approach to large graph visualization based on computing the topological similarity of graphs using graph kernels. For a given graph, our approach can show what the graph would look like in different layouts and estimate their corresponding aesthetic metrics. An important contribution of our work is the development of a new framework to design graph kernels. Our experimental study shows that our estimation calculation is considerably faster than computing the actual layouts and their aesthetic metrics. Also, our graph kernels outperform the state-of-the-art ones in both time and accuracy. In addition, we conducted a user study to demonstrate that the topological similarity computed with our graph kernel matches perceptual similarity assessed by human users.
Phonological working memory in German children with poor reading and spelling abilities.
Steinbrink, Claudia; Klatte, Maria
2008-11-01
Deficits in verbal short-term memory have been identified as one factor underlying reading and spelling disorders. However, the nature of this deficit is still unclear. It has been proposed that poor readers make less use of phonological coding, especially if the task can be solved through visual strategies. In the framework of Baddeley's phonological loop model, this study examined serial recall performance in German second-grade children with poor vs good reading and spelling abilities. Children were presented with four-item lists of common nouns for immediate serial recall. Word length and phonological similarity as well as presentation modality (visual vs auditory) and type of recall (visual vs verbal) were varied as within-subject factors in a mixed design. Word length and phonological similarity effects did not differ between groups, thus indicating equal use of phonological coding and rehearsal in poor and good readers. However, in all conditions, except the one that combined visual presentation and visual recall, overall performance was significantly lower in poor readers. The results suggest that the poor readers' difficulties do not arise from an avoidance of the phonological loop, but from its inefficient use. An alternative account referring to unstable phonological representations in long-term memory is discussed. Copyright (c) 2007 John Wiley & Sons, Ltd.
Mathematics skills in good readers with hydrocephalus.
Barnes, Marcia A; Pengelly, Sarah; Dennis, Maureen; Wilkinson, Margaret; Rogers, Tracey; Faulkner, Heather
2002-01-01
Children with hydrocephalus have poor math skills. We investigated the nature of their arithmetic computation errors by comparing written subtraction errors in good readers with hydrocephalus, typically developing good readers of the same age, and younger children matched for math level to the children with hydrocephalus. Children with hydrocephalus made more procedural errors (although not more fact retrieval or visual-spatial errors) than age-matched controls; they made the same number of procedural errors as younger, math-level matched children. We also investigated a broad range of math abilities, and found that children with hydrocephalus performed more poorly than age-matched controls on tests of geometry and applied math skills such as estimation and problem solving. Computation deficits in children with hydrocephalus reflect delayed development of procedural knowledge. Problems in specific math domains such as geometry and applied math, were associated with deficits in constituent cognitive skills such as visual spatial competence, memory, and general knowledge.
Visual Search Performance in Patients with Vision Impairment: A Systematic Review.
Senger, Cassia; Margarido, Maria Rita Rodrigues Alves; De Moraes, Carlos Gustavo; De Fendi, Ligia Issa; Messias, André; Paula, Jayter Silva
2017-11-01
Patients with visual impairment are constantly facing challenges to achieve an independent and productive life, which depends upon both a good visual discrimination and search capacities. Given that visual search is a critical skill for several daily tasks and could be used as an index of the overall visual function, we investigated the relationship between vision impairment and visual search performance. A comprehensive search was undertaken using electronic PubMed, EMBASE, LILACS, and Cochrane databases from January 1980 to December 2016, applying the following terms: "visual search", "visual search performance", "visual impairment", "visual exploration", "visual field", "hemianopia", "search time", "vision lost", "visual loss", and "low vision". Two hundred seventy six studies from 12,059 electronic database files were selected, and 40 of them were included in this review. Studies included participants of all ages, both sexes, and the sample sizes ranged from 5 to 199 participants. Visual impairment was associated with worse visual search performance in several ophthalmologic conditions, which were either artificially induced, or related to specific eye and neurological diseases. This systematic review details all the described circumstances interfering with visual search tasks, highlights the need for developing technical standards, and outlines patterns for diagnosis and therapy using visual search capabilities.
Teaching Argumentation through the Visual Models in a Resource-Based Learning Environment
ERIC Educational Resources Information Center
Chang, Shu-Nu
2007-01-01
Scientific literacy is the ultimate goal in science education world-wide; especially in this modern society of science and technology. How to help individuals to make good judgments and promote their skills of argumentation becomes an important issue. Meanwhile, in the Information Age, visual image is an important medium for conveying information.…
Using Visual Strategies to Support Verbal Comprehension in an Adolescent with Down Syndrome
ERIC Educational Resources Information Center
Lecas, Jean-Francois; Mazaud, Anne-Marie; Reibel, Esther; Rey, Arnaud
2011-01-01
It has been frequently reported that children with Down syndrome have deficits in verbal short-term memory while having relatively good performance in visual short-term memory tasks. Such verbal deficits have a detrimental effect on various high-level cognitive processes, most notably language comprehension. In this study, we report the case of an…
Programmed Control of Optical Grating Scales for Visual Research.
1980-12-01
A -AOO .9 AIR FORCE INST OF TECH WRIGHT-PATTERSON AFB OH SCHOO--ETC F/6 14/2 PROGRAMMED CONTROL OF OPTI CAL GRATING SCALES FOR VISUAL RESEARC --ETC(fl...custom system for AMRL. The cost in memory parts alone was $40,000, a good indication that the market is not over-priced. Ca-? western Reserve
ERIC Educational Resources Information Center
Kabbeko, Erica
2008-01-01
Good design brings the excitement of the Olympic Games into the visual realm of public media. Inspired by the design involved in the making of the Olympic Games, the author developed a lesson called Fashion Forward. Fashion Forward, which is taught to ninth and tenth graders, is based on the enduring idea that visual images are power communication…
Variability in the Length and Frequency of Steps of Sighted and Visually Impaired Walkers
ERIC Educational Resources Information Center
Mason, Sarah J.; Legge, Gordon E.; Kallie, Christopher S.
2005-01-01
The variability of the length and frequency of steps was measured in sighted and visually impaired walkers at three different paces. The variability was low, especially at the preferred pace, and similar for both groups. A model incorporating step counts and step frequency provides good estimates of the distance traveled. Applications to…
The Effect of Script on Poor Readers' Sensitivity to Dynamic Visual Stimuli
ERIC Educational Resources Information Center
Kim, Jeesun; Davis, Chris; Burnham, Denis; Luksaneeyanawin, Sudaporn
2004-01-01
The current research examined performance of good and poor readers of Thai on two tasks that assess sensitivity to dynamic visual displays. Readers of Thai, a complex alphabetic script that nonetheless has a regular orthography, were chosen in order to contrast patterns of performance with readers of Korean Hangul (a similarly regular language but…
Algorithm Visualization: The State of the Field
ERIC Educational Resources Information Center
Shaffer, Clifford A.; Cooper, Matthew L.; Alon, Alexander Joel D.; Akbar, Monika; Stewart, Michael; Ponce, Sean; Edwards, Stephen H.
2010-01-01
We present findings regarding the state of the field of Algorithm Visualization (AV) based on our analysis of a collection of over 500 AVs. We examine how AVs are distributed among topics, who created them and when, their overall quality, and how they are disseminated. There does exist a cadre of good AVs and active developers. Unfortunately, we…
Minerals Price Increases and Volatility: Causes and Consequences
2008-10-03
goods , used to make final products, rose 8%. Both rates are triple those at this time [in 2007].8 A 2008 report for Lehman Brothers, a New York-based...products, which are the most widely used intermediate goods produced from iron ore (all ferrous scrap was originally processed from iron ore). Some...prices, even though demand for final goods using steel products was not nearly so robust. The clearest example is in sheet steel, which, in the first
NASA Astrophysics Data System (ADS)
Hu, He; Arena, Francesca; Gianolio, Eliana; Boffa, Cinzia; di Gregorio, Enza; Stefania, Rachele; Orio, Laura; Baroni, Simona; Aime, Silvio
2016-03-01
A novel fluorescein/Gd-DOTAGA containing nanoprobe for the visualization of tumors by optical and Magnetic Resonance Imaging (MRI) is reported herein. It is based on the functionalization of the surface of small mesoporous silica nanoparticles (MSNs) (~30 nm) with the arginine-glycine-aspartic (RGD) moieties, which are known to target αvβ3 integrin receptors overexpressed in several tumor cells. The obtained nanoprobe (Gd-MSNs-RGD) displays good stability, tolerability and high relaxivity (37.6 mM-1 s-1 at 21.5 MHz). After a preliminary evaluation of their cytotoxicity and targeting capability toward U87MG cells by in vitro fluorescence and MR imaging, the nanoprobes were tested in vivo by T1-weighted MR imaging of xenografted murine tumor models. The obtained results demonstrated that the Gd-MSNs-RGD nanoprobes are good reporters both in vitro and in vivo for the MR-visualization of tumor cells overexpressing αvβ3 integrin receptors.A novel fluorescein/Gd-DOTAGA containing nanoprobe for the visualization of tumors by optical and Magnetic Resonance Imaging (MRI) is reported herein. It is based on the functionalization of the surface of small mesoporous silica nanoparticles (MSNs) (~30 nm) with the arginine-glycine-aspartic (RGD) moieties, which are known to target αvβ3 integrin receptors overexpressed in several tumor cells. The obtained nanoprobe (Gd-MSNs-RGD) displays good stability, tolerability and high relaxivity (37.6 mM-1 s-1 at 21.5 MHz). After a preliminary evaluation of their cytotoxicity and targeting capability toward U87MG cells by in vitro fluorescence and MR imaging, the nanoprobes were tested in vivo by T1-weighted MR imaging of xenografted murine tumor models. The obtained results demonstrated that the Gd-MSNs-RGD nanoprobes are good reporters both in vitro and in vivo for the MR-visualization of tumor cells overexpressing αvβ3 integrin receptors. Electronic supplementary information (ESI) available: Absorption and emission spectra, energy dispersive X-ray analysis (EDXA) and XPS spectra, TGA, zeta-potential and the molecular structures of the Gd-complexes. See DOI: 10.1039/c5nr08878j
Intrusion Detection System Visualization of Network Alerts
2010-07-01
Intrusion Detection System Visualization of Network Alerts Dolores M. Zage and Wayne M. Zage Ball State University Final Report July 2010...contracts. Staff Wayne Zage, Director of the S2ERC and Professor, Department of Computer Science, Ball State University Dolores Zage, Research
Visualizing SPH Cataclysmic Variable Accretion Disk Simulations with Blender
NASA Astrophysics Data System (ADS)
Kent, Brian R.; Wood, Matthew A.
2015-01-01
We present innovative ways to use Blender, a 3D graphics package, to visualize smoothed particle hydrodynamics particle data of cataclysmic variable accretion disks. We focus on the methods of shape key data constructs to increasedata i/o and manipulation speed. The implementation of the methods outlined allow for compositing of the various visualization layers into a final animation. The viewing of the disk in 3D from different angles can allow for a visual analysisof the physical system and orbits. The techniques have a wide ranging set of applications in astronomical visualization,including both observation and theoretical data.
Changes in Visual Function in the Elderly Population in the United States: 1995-2010.
Chen, Yiqun; Hahn, Paul; Sloan, Frank A
2016-06-01
To document recent trends in visual function among the United States population aged 70+ years and investigate how the trends can be explained by inter-temporal changes in: (1) population sociodemographic characteristics, and chronic disease prevalence, including eye diseases (compositional changes); and (2) effects of the above factors on visual function (structural changes). Data from the 1995 Asset and Health Dynamics among the Oldest Old (AHEAD) and the 2010 Health and Retirement Study (HRS) were merged with Medicare Part B claims in the interview years and the 2 previous years. Decomposition analysis was performed. Respondents from both studies were aged 70+ years. The outcome measure was respondent self-reported visual function on a 6-point scale (from 6 = blind to 1 = excellent). Overall, visual function improved from slightly worse than good (3.14) in 1995 to slightly better than good (2.98) in 2010. A decline in adverse effects of aging on vision was found. Among the compositional changes were higher educational attainment leading to improved vision, and higher prevalence of such diseases as diabetes mellitus, which tended to lower visual function. However, compared to compositional changes, structural changes were far more important, including decreased adverse effects of aging, diabetes mellitus (when not controlling for eye diseases), and diagnosed glaucoma. Although the US population has aged and is expected to age further, visual function improved among elderly persons, especially among persons 80+ years, likely reflecting a favorable role of structural changes identified in this study in mitigating the adverse effect of ongoing aging on vision.
12 CFR Appendix C to Part 707 - Official Staff Interpretations
Code of Federal Regulations, 2012 CFR
2012-01-01
... and Regulations. Good faith compliance with this commentary affords protection from liability under... messages in visual, oral, or print media that invite, offer, or otherwise announce generally to members and..., “prospective rates” are rates set in good faith in advance of the close of a dividend period, that may be...
12 CFR Appendix C to Part 707 - Official Staff Interpretations
Code of Federal Regulations, 2011 CFR
2011-01-01
... and Regulations. Good faith compliance with this commentary affords protection from liability under... messages in visual, oral, or print media that invite, offer, or otherwise announce generally to members and..., “prospective rates” are rates set in good faith in advance of the close of a dividend period, that may be...
Mapping scientific frontiers : the quest for knowledge visualization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyack, Kevin W.
Visualization of scientific frontiers is a relatively new field, yet it has a long history and many predecessors. The application of science to science itself has been undertaken for decades with notable early contributions by Derek Price, Thomas Kuhn, Diana Crane, Eugene Garfield, and many others. What is new is the field of information visualization and application of its techniques to help us understand the process of science in the making. In his new book, Chaomei Chen takes us on a journey through this history, touching on predecessors, and then leading us firmly into the new world of Mapping Scientificmore » Frontiers. Building on the foundation of his earlier book, Information Visualization and Virtual Environments, Chen's new offering is much less a tutorial in how to do information visualization, and much more a conceptual exploration of why and how the visualization of science can change the way we do science, amplified by real examples. Chen's stated intents for the book are: (1) to focus on principles of visual thinking that enable the identification of scientific frontiers; (2) to introduce a way to systematize the identification of scientific frontiers (or paradigms) through visualization techniques; and (3) to stimulate interdisciplinary research between information visualization and information science researchers. On all these counts, he succeeds. Chen's book can be broken into two parts which focus on the first two purposes stated above. The first, consisting of the initial four chapters, covers history and predecessors. Kuhn's theory of normal science punctuated by periods of revolution, now commonly known as paradigm shifts, motivates the work. Relevant predecessors outside the traditional field of information science such as cartography (both terrestrial and celestial), mapping the mind, and principles of visual association and communication, are given ample coverage. Chen also describes enabling techniques known to information scientists, such as multi-dimensional scaling, advanced dimensional reduction, social network analysis, Pathfinder network scaling, and landscape visualizations. No algorithms are given here; rather, these techniques are described from the point of view of enabling 'visual thinking'. The Generalized Similarity Analysis (GSA) technique used by Chen in his recent published papers is also introduced here. Information and computer science professionals would be wise not to skip through these early chapters. Although principles of gestalt psychology, cartography, thematic maps, and association techniques may be outside their technology comfort zone, or interest, these predecessors lay a groundwork for the 'visual thinking' that is required to create effective visualizations. Indeed, the great challenge in information visualization is to transform the abstract and intangible into something visible, concrete, and meaningful to the user. The second part of the book, covering the final three chapters, extends the mapping metaphor into the realm of scientific discovery through the structuring of literatures in a way that enables us to see scientific frontiers or paradigms. Case studies are used extensively to show the logical progression that has been made in recent years to get us to this point. Homage is paid to giants of the last 20 years including Michel Callon for co-word mapping, Henry Small for document co-citation analysis and specialty narratives (charting a path linking the different sciences), and Kate McCain for author co-citation analysis, whose work has led to the current state-of-the-art. The last two chapters finally answer the question - 'What does a scientific paradigm look like?' The visual answer given is specific to the GSA technique used by Chen, but does satisfy the intent of the book - to introduce a way to visually identify scientific frontiers. A variety of case studies, mostly from Chen's previously published work - supermassive black holes, cross-domain applications of Pathfinder networks, mass extinction debates, impact of Don Swanson's work, and mad cow disease and vCJD in humans - succeed in explaining how visualization can be used to show the development of, competition between, and eventual acceptance (or replacement) of scientific paradigms. Although not addressed specifically, Chen's work nonetheless makes the persuasive argument that visual maps alone are not sufficient to explain 'the making of science' to a non-expert in a particular field. Rather, expert knowledge is still required to interpret these maps and to explain the paradigms. This combination of visual maps and expert knowledge, used jointly to good effect in the book, becomes a potent means for explaining progress in science to the expert and non-expert alike. Work to extend the GSA technique to explore latent domain knowledge (important work that falls below the citation thresholds typically used in GSA) is also explored here.« less
Long term records of lake clarity as an indicator for final ecosystem goods and services of lakes
We reviewed available long-term records of lake clarity (via secchi disc readings) as an indicator of final ecosystem goods and services of lakes. Lake water quality assessments are often based on biophysical indicators not explicitly or quantifiably linked to the ecosystem servi...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-07
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-943] Certain Oil Country Tubular Goods From the People's Republic of China: Amended Final Results of Antidumping Duty Administrative Review; 2010-2011 AGENCY: Import Administration, International Trade Administration, Department of Commerce. DATES: Effective February 6, 2013. FOR...
Carbon Smackdown: Visualizing Clean Energy (LBNL Summer Lecture Series)
Meza, Juan [LBNL Computational Research Division
2017-12-09
The final Carbon Smackdown match took place Aug. 9, 2010. Juan Meza of the Computational Research Division revealed how scientists use computer visualizations to accelerate climate research and discuss the development of next-generation clean energy technologies such as wind turbines and solar cells.
78 FR 25521 - Revised Medical Criteria for Evaluating Visual Disorders
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-01
... SOCIAL SECURITY ADMINISTRATION [Docket No. SSA-2010-0078] Revised Medical Criteria for Evaluating Visual Disorders AGENCY: Social Security Administration. ACTION: Final rules; Correction. SUMMARY: The Social Security Administration published a document in the Federal Register of March 28, 2013, in FR Doc...
Theodossiadis, G P; Panopoulos, M; Kollia, A K; Georgopoulos, G
1992-08-01
During the period 1970-87 we evaluated the changes of the optic disc, peripapillary area, detached macula and visual acuity in 16 cases with congenital pit of the optic nerve and macular detachment. The study revealed in 9 of the 16 cases (56%) an increase of the dimension of the pit or changes in its color, findings which were directly related to the duration of the macular detachment. Chorioretinal scarring, pigment migration, or both, were also noted mainly at the temporal margin of optic disc. In 5/16 cases we found during the follow-up an extension of macular elevation. In altogether 10 out of 16 cases the retinal elevation covered the larger portion of the mid-periphery temporally. In 7/16 cases the final visual acuity remained unchanged, in 9/16 cases deteriorated. The difference, however, in the latter 9 cases between initial and final visual acuity was negligible. During the follow-up period deterioration of the visual fields was also noted.
The Role of Visual Processing Speed in Reading Speed Development
Lobier, Muriel; Dubois, Matthieu; Valdois, Sylviane
2013-01-01
A steady increase in reading speed is the hallmark of normal reading acquisition. However, little is known of the influence of visual attention capacity on children's reading speed. The number of distinct visual elements that can be simultaneously processed at a glance (dubbed the visual attention span), predicts single-word reading speed in both normal reading and dyslexic children. However, the exact processes that account for the relationship between the visual attention span and reading speed remain to be specified. We used the Theory of Visual Attention to estimate visual processing speed and visual short-term memory capacity from a multiple letter report task in eight and nine year old children. The visual attention span and text reading speed were also assessed. Results showed that visual processing speed and visual short term memory capacity predicted the visual attention span. Furthermore, visual processing speed predicted reading speed, but visual short term memory capacity did not. Finally, the visual attention span mediated the effect of visual processing speed on reading speed. These results suggest that visual attention capacity could constrain reading speed in elementary school children. PMID:23593117
The role of visual processing speed in reading speed development.
Lobier, Muriel; Dubois, Matthieu; Valdois, Sylviane
2013-01-01
A steady increase in reading speed is the hallmark of normal reading acquisition. However, little is known of the influence of visual attention capacity on children's reading speed. The number of distinct visual elements that can be simultaneously processed at a glance (dubbed the visual attention span), predicts single-word reading speed in both normal reading and dyslexic children. However, the exact processes that account for the relationship between the visual attention span and reading speed remain to be specified. We used the Theory of Visual Attention to estimate visual processing speed and visual short-term memory capacity from a multiple letter report task in eight and nine year old children. The visual attention span and text reading speed were also assessed. Results showed that visual processing speed and visual short term memory capacity predicted the visual attention span. Furthermore, visual processing speed predicted reading speed, but visual short term memory capacity did not. Finally, the visual attention span mediated the effect of visual processing speed on reading speed. These results suggest that visual attention capacity could constrain reading speed in elementary school children.
Moreno-Granados, Josefa María; Ferrín, Maite; Salcedo-Marín, Dolores M; Ruiz-Veguilla, Miguel
2014-01-01
The importance of neuropsychological functioning in First-Episode Psychosis (FEP) has led to the publication of a growing number of studies in this area of research. The present study pursued three goals: First, to examine verbal and visual memory in a sample of Child and Adolescent FEP, second, to evaluate the effect of other cognitive domains on verbal and visual memory, and finally, to examine the relationship between performance in this cognitive dimension and the use of cannabis at this age. A sample of 41 FEPs and 39 healthy subjects were evaluated. The variables assessed were verbal and visual memory, attention, working memory, processing speed, mental flexibility, verbal fluency, motor coordination, planning ability and intelligence. Our results found impairment of short and long-term recall of verbal memory, and short-term visual memory in early psychosis. They also found relationships between cognitive dimensions, such as visual memory and intelligence and motor coordination. Finally, a «paradoxical» effect was found in patients who used cannabis, as the FEP consumers performed the visual memory test better than those who had not used it. Patients showed impairment of short and long-term recall of verbal information and short-term visual reproduction. In the second place, motor coordination and intelligence influenced short-term visual memory in patients in the early stages of the illness. Third, use of cannabis in patients with FEP was associated with better performance in the test that evaluated the short-term visual memory, as measured by task completion time, that is, efficiency in performing the test. However, when measured by task execution accuracy, their visual memory was no better than the controls. Copyright © 2012 SEP y SEPB. Published by Elsevier España. All rights reserved.
Hallux Valgus Correction Comparing Percutaneous Chevron/Akin (PECA) and Open Scarf/Akin Osteotomies.
Lee, Moses; Walsh, James; Smith, Margaret M; Ling, Jeff; Wines, Andrew; Lam, Peter
2017-08-01
Minimally invasive surgery is being used increasingly, including for hallux valgus surgery. Despite the growing interest in minimally invasive procedures, there have been few publications on percutaneous chevron/akin (PECA) procedures, and no studies have been published comparing PECA to open scarf/akin osteotomies (SA). This was a prospective, randomized study of 50 patients undergoing operative correction of hallux valgus using one of 2 techniques (PECA vs open SA). Data were collected preoperatively and on 1 day, 2 weeks, 6 weeks, and 6 months postoperatively. Outcome measures include the American Orthopaedic Foot & Ankle Society Hallux-Metatarsophalangeal-Interphalangeal (AOFAS-HMI) Score, visual analog pain score, hallux valgus angle (HVA), and 1-2 intermetatarsal angle (IMA). Twenty-five patients underwent PECA procedures and 25 patients received SA procedures. Both groups showed significantly improved AOFAS-HMI scores after surgery (PECA group: 61.8 to 88.9, SA group: 57.3 to 84.1, P = .560) with comparable final scores. HVA and IMA also presented similar outcomes at final follow-up ( P = .520 and P = .270, respectively). However, the PECA group showed significantly lower pain level (VAS) in the early postoperative phase (postoperative day 1 to postoperative week 6, P < .001 and P = .004, respectively). No serious complications were observed in either group. Both groups showed comparable good to excellent clinical and radiologic outcomes at final follow-up. However, the PECA group had significantly less pain in the first 6 weeks following surgery. Level of Evidence Level II, prospective comparative study.
Detecting Driver Mental Fatigue Based on EEG Alpha Power Changes during Simulated Driving.
Gharagozlou, Faramarz; Nasl Saraji, Gebraeil; Mazloumi, Adel; Nahvi, Ali; Motie Nasrabadi, Ali; Rahimi Foroushani, Abbas; Arab Kheradmand, Ali; Ashouri, Mohammadreza; Samavati, Mehdi
2015-12-01
Driver fatigue is one of the major implications in transportation safety and accounted for up to 40% of road accidents. This study aimed to analyze the EEG alpha power changes in partially sleep-deprived drivers while performing a simulated driving task. Twelve healthy male car drivers participated in an overnight study. Continuous EEG and EOG records were taken during driving on a virtual reality simulator on a monotonous road. Simultaneously, video recordings from the driver face and behavior were performed in lateral and front views and rated by two trained observers. Moreover, the subjective self-assessment of fatigue was implemented in every 10-min interval during the driving using Fatigue Visual Analog Scale (F-VAS). Power spectrum density and fast Fourier transform (FFT) were used to determine the absolute and relative alpha powers in the initial and final 10 minutes of driving. The findings showed a significant increase in the absolute alpha power (P = 0.006) as well as F-VAS scores during the final section of driving (P = 0.001). Meanwhile, video ratings were consistent with subjective self-assessment of fatigue. The increase in alpha power in the final section of driving indicates the decrease in the level of alertness and attention and the onset of fatigue, which was consistent with F-VAS and video ratings. The study suggested that variations in alpha power could be a good indicator for driver mental fatigue, but for using as a countermeasure device needed further investigations.
ERIC Educational Resources Information Center
Tetteh, Edem; McWilliams, Douglas
2010-01-01
Customer needs for high-quality goods and the risk of product-liability litigation against businesses have made companies look for a way to sustain quality assurance in their products and services. Lean manufacturing is the latest and most successful system being used by companies to turn their business around. Visual inspection plays an important…
ERIC Educational Resources Information Center
Kuo, Ming-Shiou; Chuang, Tsung-Yen
2013-01-01
The teaching of 3D digital game design requires the development of students' meta-skills, from story creativity to 3D model construction, and even the visualization process in design thinking. The characteristics a good game designer should possess have been identified as including redesign things, creativity thinking and the ability to…
ERIC Educational Resources Information Center
Eidels, Ami; Townsend, James T.; Pomerantz, James R.
2008-01-01
People are especially efficient in processing certain visual stimuli such as human faces or good configurations. It has been suggested that topology and geometry play important roles in configural perception. Visual search is one area in which configurality seems to matter. When either of 2 target features leads to a correct response and the…
Meteor Shower observations from the Indian Sub-Continent (Visual Photographic and Radio)
NASA Astrophysics Data System (ADS)
Dabhade, R.; Savant, V.; Belapure, J.
2011-01-01
We review the present status of meteor shower observing from the Indian sub-continent. Some amateur groups are active in visual observations, although they are restricted by the lack of good observing sites. Ham radio appears to be promising as a technique to monitor the major meteor showers in this region. We present radio observations of the 2006 Quadrantids.
visCOS: An R-package to evaluate model performance of hydrological models
NASA Astrophysics Data System (ADS)
Klotz, Daniel; Herrnegger, Mathew; Wesemann, Johannes; Schulz, Karsten
2016-04-01
The evaluation of model performance is a central part of (hydrological) modelling. Much attention has been given to the development of evaluation criteria and diagnostic frameworks. (Klemeš, 1986; Gupta et al., 2008; among many others). Nevertheless, many applications exist for which objective functions do not yet provide satisfying summaries. Thus, the necessity to visualize results arises in order to explore a wider range of model capacities, be it strengths or deficiencies. Visualizations are usually devised for specific projects and these efforts are often not distributed to a broader community (e.g. via open source software packages). Hence, the opportunity to explicitly discuss a state-of-the-art presentation technique is often missed. We therefore present a comprehensive R-package for evaluating model performance by visualizing and exploring different aspects of hydrological time-series. The presented package comprises a set of useful plots and visualization methods, which complement existing packages, such as hydroGOF (Zambrano-Bigiarini et al., 2012). It is derived from practical applications of the hydrological models COSERO and COSEROreg (Kling et al., 2014). visCOS, providing an interface in R, represents an easy-to-use software package for visualizing and assessing model performance and can be implemented in the process of model calibration or model development. The package provides functions to load hydrological data into R, clean the data, process, visualize, explore and finally save the results in a consistent way. Together with an interactive zoom function of the time series, an online calculation of the objective functions for variable time-windows is included. Common hydrological objective functions, such as the Nash-Sutcliffe Efficiency and the Kling-Gupta Efficiency, can also be evaluated and visualized in different ways for defined sub-periods like hydrological years or seasonal sections. Many hydrologists use long-term water-balances as a pivotal tool in model evaluation. They allow inferences about different systematic model-shortcomings and are an efficient way for communicating these in practice (Schulz et al., 2015). The evaluation and construction of such water balances is implemented with the presented package. During the (manual) calibration of a model or in the scope of model development, many model runs and iterations are necessary. Thus, users are often interested in comparing different model results in a visual way in order to learn about the model and to analyse parameter-changes on the output. A method to illuminate these differences and the evolution of changes is also included. References: • Gupta, H.V.; Wagener, T.; Liu, Y. (2008): Reconciling theory with observations: elements of a diagnostic approach to model evaluation, Hydrol. Process. 22, doi: 10.1002/hyp.6989. • Klemeš, V. (1986): Operational testing of hydrological simulation models, Hydrolog. Sci. J., doi: 10.1080/02626668609491024. • Kling, H.; Stanzel, P.; Fuchs, M.; and Nachtnebel, H. P. (2014): Performance of the COSERO precipitation-runoff model under non-stationary conditions in basins with different climates, Hydrolog. Sci. J., doi: 10.1080/02626667.2014.959956. • Schulz, K., Herrnegger, M., Wesemann, J., Klotz, D. Senoner, T. (2015): Kalibrierung COSERO - Mur für Pro Vis, Verbund Trading GmbH (Abteilung STG), final report, Institute of Water Management, Hydrology and Hydraulic Engineering, University of Natural Resources and Applied Life Sciences, Vienna, Austria, 217pp. • Zambrano-Bigiarini, M; Bellin, A. (2010): Comparing Goodness-of-fit Measures for Calibration of Models Focused on Extreme Events. European Geosciences Union (EGU), Geophysical Research Abstracts 14, EGU2012-11549-1.
Long-term surgical outcomes of retinal detachment in patients with Stickler syndrome
Reddy, Devasis N; Yonekawa, Yoshihiro; Thomas, Benjamin J; Nudleman, Eric D; Williams, George A
2016-01-01
Purpose The aim of the study was to present the long-term anatomical and visual outcomes of retinal detachment repair in patients with Stickler syndrome. Patients and methods This study is a retrospective, interventional, consecutive case series of patients with Stickler syndrome undergoing retinal reattachment surgery from 2009 to 2014 at the Associated Retinal Consultants, William Beaumont Hospital. Results Sixteen eyes from 13 patients were identified. Patients underwent a mean of 3.1 surgical interventions (range: 1–13) with a mean postoperative follow-up of 94 months (range: 5–313 months). Twelve eyes (75%) developed proliferative vitreoretinopathy. Retinal reattachment was achieved in 100% of eyes, with ten eyes (63%) requiring silicone oil tamponade at final follow-up. Mean preoperative visual acuity (VA) was 20/914, which improved to 20/796 at final follow-up (P=0.81). There was a significant correlation between presenting and final VA (P<0.001), and patients with poorer presenting VA were more likely to require silicone oil tamponade at final follow-up (P=0.04). Conclusion Repair of retinal detachment in patients with Stickler syndrome often requires multiple surgeries, and visual outcomes are variable. Presenting VA is significantly predictive of long-term VA outcomes. PMID:27574392
Visualizing deep neural network by alternately image blurring and deblurring.
Wang, Feng; Liu, Haijun; Cheng, Jian
2018-01-01
Visualization from trained deep neural networks has drawn massive public attention in recent. One of the visualization approaches is to train images maximizing the activation of specific neurons. However, directly maximizing the activation would lead to unrecognizable images, which cannot provide any meaningful information. In this paper, we introduce a simple but effective technique to constrain the optimization route of the visualization. By adding two totally inverse transformations, image blurring and deblurring, to the optimization procedure, recognizable images can be created. Our algorithm is good at extracting the details in the images, which are usually filtered by previous methods in the visualizations. Extensive experiments on AlexNet, VGGNet and GoogLeNet illustrate that we can better understand the neural networks utilizing the knowledge obtained by the visualization. Copyright © 2017 Elsevier Ltd. All rights reserved.
Neural correlates of individual performance differences in resolving perceptual conflict.
Labrenz, Franziska; Themann, Maria; Wascher, Edmund; Beste, Christian; Pfleiderer, Bettina
2012-01-01
Attentional mechanisms are a crucial prerequisite to organize behavior. Most situations may be characterized by a 'competition' between salient, but irrelevant stimuli and less salient, relevant stimuli. In such situations top-down and bottom-up mechanisms interact with each other. In the present fMRI study, we examined how interindividual differences in resolving situations of perceptual conflict are reflected in brain networks mediating attentional selection. Doing so, we employed a change detection task in which subjects had to detect luminance changes in the presence and absence of competing distractors. The results show that good performers presented increased activation in the orbitofrontal cortex (BA 11), anterior cingulate (BA 25), inferior parietal lobule (BA 40) and visual areas V2 and V3 but decreased activation in BA 39. This suggests that areas mediating top-down attentional control are stronger activated in this group. Increased activity in visual areas reflects distinct neuronal enhancement relating to selective attentional mechanisms in order to solve the perceptual conflict. Opposed to good performers, brain areas activated by poor performers comprised the left inferior parietal lobule (BA 39) and fronto-parietal and visual regions were continuously deactivated, suggesting that poor performers perceive stronger conflict than good performers. Moreover, the suppression of neural activation in visual areas might indicate a strategy of poor performers to inhibit the processing of the irrelevant non-target feature. These results indicate that high sensitivity in perceptual areas and increased attentional control led to less conflict in stimulus processing and consequently to higher performance in competitive attentional selection.
Tabrizi, Yousef Moghadas; Zangiabadi, Nasser; Mazhari, Shahrzad; Zolala, Farzaneh
2013-01-01
Objective Motor imagery (MI) has been recently considered as an adjunct to physical rehabilitation in patients with multiple sclerosis (MS). It is necessary to assess MI abilities and benefits in patients with MS by using a reliable tool. The Kinesthetic and Visual Imagery Questionnaire (KVIQ) was recently developed to assess MI ability in patients with stroke and other disabilities. Considering the different underlying pathologies, the present study aimed to examine the validity and reliability of the KVIQ in MS patients. Method Fifteen MS patients were assessed using the KVIQ in 2 sessions (5-14days apart) by the same examiner. In the second session, the participants also completed a revised MI questionnaire (MIQ-R) as the gold standard. Intra-class correlation coefficients (ICCs) were measured to determine test-retest reliability. Spearman's correlation analysis was performed to assess concurrent validity with the MIQ-R. Furthermore, the internal consistency (Cronbach's alpha) and factorial structure of the KVIQ were studied. Results The test-retest reliability for the KVIQ was good (ICCs: total KVIQ=0.89, visual KVIQ=0.85, and kinesthetic KVIQ=0.93), and the concurrent validity between the KVIQ and MIQ-R was good (r=0.79). The KVIQ had good internal consistency, with high Cronbach's alpha (alpha=0.84). Factorial analysis showed the bi-factorial structure of the KVIQ, which was explained by visual=57.6% and kinesthetic=32.4%. Conclusions The results of the present study revealed that the KVIQ is a valid and reliable tool for assessing MI in MS patients. PMID:24271091
Tabrizi, Yousef Moghadas; Zangiabadi, Nasser; Mazhari, Shahrzad; Zolala, Farzaneh
2013-01-01
Motor imagery (MI) has been recently considered as an adjunct to physical rehabilitation in patients with multiple sclerosis (MS). It is necessary to assess MI abilities and benefits in patients with MS by using a reliable tool. The Kinesthetic and Visual Imagery Questionnaire (KVIQ) was recently developed to assess MI ability in patients with stroke and other disabilities. Considering the different underlying pathologies, the present study aimed to examine the validity and reliability of the KVIQ in MS patients. Fifteen MS patients were assessed using the KVIQ in 2 sessions (5-14 days apart) by the same examiner. In the second session, the participants also completed a revised MI questionnaire (MIQ-R) as the gold standard. Intra-class correlation coefficients (ICCs) were measured to determine test-retest reliability. Spearman's correlation analysis was performed to assess concurrent validity with the MIQ-R. Furthermore, the internal consistency (Cronbach's alpha) and factorial structure of the KVIQ were studied. The test-retest reliability for the KVIQ was good (ICCs: total KVIQ=0.89, visual KVIQ=0.85, and kinesthetic KVIQ=0.93), and the concurrent validity between the KVIQ and MIQ-R was good (r=0.79). The KVIQ had good internal consistency, with high Cronbach's alpha (alpha=0.84). Factorial analysis showed the bi-factorial structure of the KVIQ, which was explained by visual=57.6% and kinesthetic=32.4%. The results of the present study revealed that the KVIQ is a valid and reliable tool for assessing MI in MS patients.
A unified account of tilt illusions, association fields, and contour detection based on elastica.
Keemink, Sander W; van Rossum, Mark C W
2016-09-01
As expressed in the Gestalt law of good continuation, human perception tends to associate stimuli that form smooth continuations. Contextual modulation in primary visual cortex, in the form of association fields, is believed to play an important role in this process. Yet a unified and principled account of the good continuation law on the neural level is lacking. In this study we introduce a population model of primary visual cortex. Its contextual interactions depend on the elastica curvature energy of the smoothest contour connecting oriented bars. As expected, this model leads to association fields consistent with data. However, in addition the model displays tilt-illusions for stimulus configurations with grating and single bars that closely match psychophysics. Furthermore, the model explains not only pop-out of contours amid a variety of backgrounds, but also pop-out of single targets amid a uniform background. We thus propose that elastica is a unifying principle of the visual cortical network. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Gains from Trade for Nonmaterialists, Environmentalists, and the Overworked
ERIC Educational Resources Information Center
Weber, Christian E.
2007-01-01
The author proposes an alternative to the traditional definition of the gains from international trade and, hence, an alternative defense of free trade. Rather than showing that free trade allows a country to consume more of all final goods, the author's approach shows that free trade allows a country to consume the same basket of final goods that…
Ecosystem Services have received increasing scientific focus for a decade, yet the natural and social scientists working on mainstreaming these concepts are still struggling with the task. FEGS (Final Ecosystem Goods and Services) are an informative and useful concept as they emb...
Tone mapping infrared images using conditional filtering-based multi-scale retinex
NASA Astrophysics Data System (ADS)
Luo, Haibo; Xu, Lingyun; Hui, Bin; Chang, Zheng
2015-10-01
Tone mapping can be used to compress the dynamic range of the image data such that it can be fitted within the range of the reproduction media and human vision. The original infrared images that captured with infrared focal plane arrays (IFPA) are high dynamic images, so tone mapping infrared images is an important component in the infrared imaging systems, and it has become an active topic in recent years. In this paper, we present a tone mapping framework using multi-scale retinex. Firstly, a Conditional Gaussian Filter (CGF) was designed to suppress "halo" effect. Secondly, original infrared image is decomposed into a set of images that represent the mean of the image at different spatial resolutions by applying CGF of different scale. And then, a set of images that represent the multi-scale details of original image is produced by dividing the original image pointwise by the decomposed image. Thirdly, the final detail image is reconstructed by weighted sum of the multi-scale detail images together. Finally, histogram scaling and clipping is adopted to remove outliers and scale the detail image, 0.1% of the pixels are clipped at both extremities of the histogram. Experimental results show that the proposed algorithm efficiently increases the local contrast while preventing "halo" effect and provides a good rendition of visual effect.
Gogna, Paritosh; Gaba, Sahil; Mukhopadhyay, Reetadyuti; Gupta, Rakesh; Rohilla, Rajesh; Yadav, Lakhpat
2016-08-01
Plantar Fasciitis makes up about 15% of patients requiring professional care due to foot symptoms. The treatment methods are numerous with none proving to be clearly superior to others. We aimed to compare two common treatment methods in search of the best treatment. All consecutive sportspersons presenting to our OPD with clinical diagnosis of plantar fasciitis underwent treatment consisting of stretching exercises, activity modification, and NSAID's for 6 months. First 40 patients who did not respond to the treatment were divided randomly into two groups of 20 patients each, Group A (Platelet rich plasma - PRP) and Group B (low dose radiation - LDR). At the time of final follow-up (6 months) the mean improvement in the pain score (Visual-Analogue-Scale), American Orthopaedic Foot and Ankle Score (AOFAS) and Plantar fascia thickness on ultrasound were compared. Significant improvement in all 3 parameters was noted at the time of final follow up within both groups. When compared to each other, the difference in outcome of both these Groups on the given 3 parameters came out to be insignificant (p>0.05). PRP is as good as LDR in patients with chronic recalcitrant plantar fasciitis not responding to physical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mobile medical visual information retrieval.
Depeursinge, Adrien; Duc, Samuel; Eggel, Ivan; Müller, Henning
2012-01-01
In this paper, we propose mobile access to peer-reviewed medical information based on textual search and content-based visual image retrieval. Web-based interfaces designed for limited screen space were developed to query via web services a medical information retrieval engine optimizing the amount of data to be transferred in wireless form. Visual and textual retrieval engines with state-of-the-art performance were integrated. Results obtained show a good usability of the software. Future use in clinical environments has the potential of increasing quality of patient care through bedside access to the medical literature in context.
Visual sensation during pecking in pigeons.
Ostheim, J
1997-10-01
During the final down-thrust of a pigeon's head, the eyes are closed gradually, a response that was thought to block visual input. This phase of pecking was therefore assumed to be under feed-forward control exclusively. Analysis of high resolution video-recordings showed that visual information collected during the down-thrust of the head could be used for 'on-line' modulations of pecks in progress. We thus concluded that the final down-thrust of the head is not exclusively controlled by feed-forward mechanisms but also by visual feedback components. We could further establish that as a rule the eyes are never closed completely but instead the eyelids form a slit which leaves a part of the pupil uncovered. The width of the slit between the pigeon' eyelids is highly sensitive to both, ambient luminance and the visual background against which seeds are offered. It was concluded that eyelid slits increase the focal depth of retinal images at extreme near-field viewing-conditions. Applying pharmacological methods we could confirm that pupil size and eyelid slit width are controlled through conjoint neuronal mechanisms. This shared neuronal network is particularly sensitive to drugs that affect dopamine receptors.
Perceptual Grouping in Haptic Search: The Influence of Proximity, Similarity, and Good Continuation
ERIC Educational Resources Information Center
Overvliet, Krista E.; Krampe, Ralf Th.; Wagemans, Johan
2012-01-01
We conducted a haptic search experiment to investigate the influence of the Gestalt principles of proximity, similarity, and good continuation. We expected faster search when the distractors could be grouped. We chose edges at different orientations as stimuli because they are processed similarly in the haptic and visual modality. We therefore…
A Comparison of the Intellectual Abilities of Good and Poor Problem Solvers: An Exploratory Study.
ERIC Educational Resources Information Center
Meyer, Ruth Ann
This study examined a selected sample of fourth-grade students who had been previously identified as good or poor problem solvers. The pupils were compared on variables considered as "reference tests" for Verbal, Induction, Numerical, Word Fluency, Memory, Spatial Visualization, and Perceptual Speed abilities. The data were compiled to…
Grating test of contrast sensitivity in patients with Minamata disease.
Mukuno, K; Ishikawa, S; Okamura, R
1981-01-01
Thirty cases of Minamata disease caused by methyl mercury poisoning with the lesion mainly at the occipital cortex were selected and their spatial contrast sensitivity of vision was examined by the Arden grating chart. At the same time their visual acuity, visual field, and visual evoked cortical potential (VECP) were also investigated. In all cases the results of the Arden test indicated abnormality. Poor results were obtained at higher frequencies of the gratings. VECP elicited by grating pattern reversal stimulus was undertaken in 12 cases out of the 30. The results revealed abnormality almost equal to that shown by the Arden test. Seven out of the 12 cases showed no VECP response. The other 5, giving a response, showed abnormality: when the size of the grating became smaller at higher frequencies, the VECP paused or was not recorded, whereas at low frequencies it was recorded. This finding was in good agreement or was not recorded, whereas at low frequencies it was recorded. This finding was in good agreement with the results of the Arden test. Visual acuity and visual field tests were less sensitive in detecting abnormality. The Arden chart is a sensitive clinical tool for patients with lesions at the cerebral cortex. Furthermore, the test can be used for screening patients who may have come in contrast with organic mercury. PMID:7236573
Remedy and Recontamination Assessment Array
2017-03-01
of silica sand visual tracer at interface, (C) addition of thin sand layer, and (D) final result with treatment and overlying water added...Final result for thin clean sediment layer treatment after final installation of treatment and overlying water ... treatment sediments were held in the sediment cells or tubs with overlying surface water under cool conditions overnight prior to application of the
Khoramnia, Rahmin; Attia, Mary Safwat; Koss, Michael Janusz; Linz, Katharina; Auffarth, Gerd Uwe
2016-01-01
Purpose To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). Methods Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. Results The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. Conclusions The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance. PMID:27729759
Kretz, Florian Tobias Alwin; Khoramnia, Rahmin; Attia, Mary Safwat; Koss, Michael Janusz; Linz, Katharina; Auffarth, Gerd Uwe
2016-10-01
To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance.
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Triantafyllopoulos, Spiros
1985-01-01
A collection of presentation visuals associated with the companion report entitled KARL: A Knowledge-Assisted Retrieval Language, is presented. Information is given on data retrieval, natural language database front ends, generic design objectives, processing capababilities and the query processing cycle.
Neuropsychological Components of Imagery Processing, Final Technical Report.
ERIC Educational Resources Information Center
Kosslyn, Stephen M.
High-level visual processes make use of stored information, and are invoked during object identification, navigation, tracking, and visual mental imagery. The work presented in this document has resulted in a theory of the component "processing subsystems" used in high-level vision. This theory was developed by considering…
Visualizing the Zero-Potential Line of Bipolar Electrodes with Arbitrary Geometry.
Li, Meng; Liu, Shasha; Jiang, Yingyan; Wang, Wei
2018-06-05
In a typical bipolar electrochemistry (BPE) configuration, voltage applied between the two driving electrodes induced a potential drop through solution filled in the microchannel, resulting in an interfacial potential difference between solution and BPE varied along the BPE. In the present work, we employed a recently developed plasmonic imaging technique to map the distribution of surface potential of bipolar electrodes with various geometries including round, triangle, hexagon, star, and rhombus shapes under the nonfaradaic charging process, from which the line of zero potential (LZP) was visualized and determined. We further investigated the dependence of LZP on electrode geometry and the distribution of external electric field and explained the experimental results with a charge balance mechanism. The triangular and star-shaped BPEs show quite different LZP features from the other ones with symmetrical geometry. These experimentally obtained potential distributions are all in good agreement with electromagnetic simulations. Finally, the line of zero overpotential (LZO) of the triangular-shaped BPE under faradaic reactions were investigated. The results confirm the shift of LZO when faradaic reactions occurred at the corresponding ends of BPE. The present work demonstrates the first experimental capability to map the potential distribution of BPE with arbitrary geometry under an arbitrary driving field. It is anticipated to help the design and optimization on the geometry of electrodes and microchannels with implications for boosting their applications in chemical sensing and materials synthesis.
Analysis of ABCA4 in mixed Spanish families segregating different retinal dystrophies.
Paloma, Eva; Coco, Rosa; Martínez-Mir, Amalia; Vilageliu, Lluïsa; Balcells, Susana; Gonzàlez-Duarte, Roser
2002-12-01
Genotype-phenotype correlations highlighted the function of ABCA4 in retinitis pigmentosa (RP),cone-rod dystrophy (CRD) and Stargardt/Fundus Flavimaculatus disease (STGD/FFM). Initial screening of ABCA4 variants showed a correlation between the type of mutation and the severity of the disease. In the present study we have undertaken mutational and haplotype analysis of ABCA4 in three mixed pedigrees segregating different retinal dystrophies. In family I, we have shown cosegregation of different ABCA4 alleles with CRD (homozygosity for L1940P) and three subtypes of STGD/FFM. The first, a mild form, consisting on fundus flavimaculatus-like distribution of flecks, but good visual acuity and absence of dark choroid, was found to cosegregate with alleles R1097C and F553L; the second, a conventional Stargardt phenotype was associated to alleles L1940P/R1097C and the third, displaying severely reduced visual acuity and dark choroid (named FFM), was associated to L1940P/F553L. In family II, segregating STGD and RP phenotypes, while the involvement of ABCA4 in STGD seems clear this is not the case for RP. Finally, in family III, also segregating STGD and RP, ABCA4 fails to explain either phenotype. Our data highlight the wide allelic heterogeneity involving this gene and support the genetic variability (beyond ABCA4) of mixed STGD/RP pedigrees. Copyright 2002 Wiley-Liss, Inc.
Kinesthesis can make an invisible hand visible
Dieter, Kevin C.; Hu, Bo; Knill, David C.; Blake, Randolph; Tadin, Duje
2014-01-01
Self-generated body movements have reliable visual consequences. This predictive association between vision and action likely underlies modulatory effects of action on visual processing. However, it is unknown if our own actions can have generative effects on visual perception. We asked whether, in total darkness, self-generated body movements are sufficient to evoke normally concomitant visual perceptions. Using a deceptive experimental design, we discovered that waving one’s own hand in front of one’s covered eyes can cause visual sensations of motion. Conjecturing that these visual sensations arise from multisensory connectivity, we showed that individuals with synesthesia experience substantially stronger kinesthesis-induced visual sensations. Finally, we found that the perceived vividness of kinesthesis-induced visual sensations predicted participants’ ability to smoothly eye-track self-generated hand movements in darkness, indicating that these sensations function like typical retinally-driven visual sensations. Evidently, even in the complete absence of external visual input, our brains predict visual consequences of our actions. PMID:24171930
Good Teaching: Aligning Student and Administrator Perceptions and Expectations
ERIC Educational Resources Information Center
Nabaho, Lazarus; Oonyu, Joseph; Aguti, Jessica Norah
2017-01-01
Extant literature attests to limited systematic inquiry into students' perceptions of good teaching in higher education. Consequently, there have been calls for engaging students in construing what makes good university teaching. This interpretivist study investigated final-year undergraduate students' perceptions of good teaching at Makerere…
Seo, Joonho; Koizumi, Norihiro; Funamoto, Takakazu; Sugita, Naohiko; Yoshinaka, Kiyoshi; Nomiya, Akira; Homma, Yukio; Matsumoto, Yoichiro; Mitsuishi, Mamoru
2011-06-01
Applying ultrasound (US)-guided high-intensity focused ultrasound (HIFU) therapy for kidney tumours is currently very difficult, due to the unclearly observed tumour area and renal motion induced by human respiration. In this research, we propose new methods by which to track the indistinct tumour area and to compensate the respiratory tumour motion for US-guided HIFU treatment. For tracking indistinct tumour areas, we detect the US speckle change created by HIFU irradiation. In other words, HIFU thermal ablation can coagulate tissue in the tumour area and an intraoperatively created coagulated lesion (CL) is used as a spatial landmark for US visual tracking. Specifically, the condensation algorithm was applied to robust and real-time CL speckle pattern tracking in the sequence of US images. Moreover, biplanar US imaging was used to locate the three-dimensional position of the CL, and a three-actuator system drives the end-effector to compensate for the motion. Finally, we tested the proposed method by using a newly devised phantom model that enables both visual tracking and a thermal response by HIFU irradiation. In the experiment, after generation of the CL in the phantom kidney, the end-effector successfully synchronized with the phantom motion, which was modelled by the captured motion data for the human kidney. The accuracy of the motion compensation was evaluated by the error between the end-effector and the respiratory motion, the RMS error of which was approximately 2 mm. This research shows that a HIFU-induced CL provides a very good landmark for target motion tracking. By using the CL tracking method, target motion compensation can be realized in the US-guided robotic HIFU system. Copyright © 2011 John Wiley & Sons, Ltd.
Feasibility of an endotracheal tube-mounted camera for percutaneous dilatational tracheostomy.
Grensemann, J; Eichler, L; Hopf, S; Jarczak, D; Simon, M; Kluge, S
2017-07-01
Percutaneous dilatational tracheostomy (PDT) in critically ill patients is often led by optical guidance with a bronchoscope. This is not without its disadvantages. Therefore, we aimed to study the feasibility of a recently introduced endotracheal tube-mounted camera (VivaSight™-SL, ET View, Misgav, Israel) in the guidance of PDT. We studied 10 critically ill patients who received PDT with a VivaSight-SL tube that was inserted prior to tracheostomy for optical guidance. Visualization of the tracheal structures (i.e., identification and monitoring of the thyroid, cricoid, and tracheal cartilage and the posterior wall) and the quality of ventilation (before puncture and during the tracheostomy) were rated on four-point Likert scales. Respiratory variables were recorded, and blood gases were sampled before the interventions, before the puncture and before the insertion of the tracheal cannula. Visualization of the tracheal landmarks was rated as 'very good' or 'good' in all but one case. Monitoring during the puncture and dilatation was also rated as 'very good' or 'good' in all but one. In the cases that were rated 'difficult', the visualization and monitoring of the posterior wall of the trachea were the main concerns. No changes in the respiratory variables or blood gases occurred between the puncture and the insertion of the tracheal cannula. Percutaneous dilatational tracheostomy with optical guidance from a tube-mounted camera is feasible. Further studies comparing the camera tube with bronchoscopy as the standard approach should be performed. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Murthy, Aditya; Ray, Supriya; Shorter, Stephanie M; Schall, Jeffrey D; Thompson, Kirk G
2009-05-01
The dynamics of visual selection and saccade preparation by the frontal eye field was investigated in macaque monkeys performing a search-step task combining the classic double-step saccade task with visual search. Reward was earned for producing a saccade to a color singleton. On random trials the target and one distractor swapped locations before the saccade and monkeys were rewarded for shifting gaze to the new singleton location. A race model accounts for the probabilities and latencies of saccades to the initial and final singleton locations and provides a measure of the duration of a covert compensation process-target-step reaction time. When the target stepped out of a movement field, noncompensated saccades to the original location were produced when movement-related activity grew rapidly to a threshold. Compensated saccades to the final location were produced when the growth of the original movement-related activity was interrupted within target-step reaction time and was replaced by activation of other neurons producing the compensated saccade. When the target stepped into a receptive field, visual neurons selected the new target location regardless of the monkeys' response. When the target stepped out of a receptive field most visual neurons maintained the representation of the original target location, but a minority of visual neurons showed reduced activity. Chronometric analyses of the neural responses to the target step revealed that the modulation of visually responsive neurons and movement-related neurons occurred early enough to shift attention and saccade preparation from the old to the new target location. These findings indicate that visual activity in the frontal eye field signals the location of targets for orienting, whereas movement-related activity instantiates saccade preparation.
Water surface modeling from a single viewpoint video.
Li, Chuan; Pickup, David; Saunders, Thomas; Cosker, Darren; Marshall, David; Hall, Peter; Willis, Philip
2013-07-01
We introduce a video-based approach for producing water surface models. Recent advances in this field output high-quality results but require dedicated capturing devices and only work in limited conditions. In contrast, our method achieves a good tradeoff between the visual quality and the production cost: It automatically produces a visually plausible animation using a single viewpoint video as the input. Our approach is based on two discoveries: first, shape from shading (SFS) is adequate to capture the appearance and dynamic behavior of the example water; second, shallow water model can be used to estimate a velocity field that produces complex surface dynamics. We will provide qualitative evaluation of our method and demonstrate its good performance across a wide range of scenes.
Jensen, K K; Kjaer, M; Jorgensen, L N
2016-12-01
To determine the reliability of measurements obtained by the Good Strength dynamometer, determining isometric abdominal wall and back muscle strength in patients with ventral incisional hernia (VIH) and healthy volunteers with an intact abdominal wall. Ten patients with VIH and ten healthy volunteers with an intact abdominal wall were each examined twice with a 1 week interval. Examination included the assessment of truncal flexion and extension as measured with the Good Strength dynamometer, the completion of the International Physical Activity Questionnaire (IPAQ) and the self-assessment of truncal strength on a visual analogue scale (SATS). The test-retest reliability of truncal flexion and extension was assessed by interclass correlation coefficient (ICC), and Bland and Altman graphs. Finally, correlations between truncal strength, and IPAQ and SATS were examined. Truncal flexion and extension showed excellent test-retest reliability for both patients with VIH (ICC 0.91 and 0.99) and healthy controls (ICC 0.97 and 0.96). Bland and Altman plots showed that no systematic bias was present for neither truncal flexion nor extension when assessing reliability. For patients with VIH, no significant correlations between objective measures of truncal strength and IPAQ or SATS were found. For healthy controls, both truncal flexion (τ 0.58, p = 0.025) and extension (τ 0.58, p = 0.025) correlated significantly with SATS, while no other significant correlation between truncal strength measures and IPAQ was found. The Good Strength dynamometer provided a reliable, low-cost measure of truncal flexion and extension in patients with VIH.
Xiao, Jianhe; Jiang, Caihui; Zhang, Maonian; Jiang, Hua; Li, Shiyang; Zhang, Ying
2014-09-01
To report 45 cases of late traumatic flap complications after laser-assisted in situ keratomileusis (LASIK) and discuss the continually increasing number of cases in China. A multicentre retrospective survey of eye injuries was carried in 31 military hospitals from January 2006 to December 2011. Detailed information from the medical records of all 92 cases with a history of prior LASIK treatment were collected and summarised, with respect to visual acuity (VA), flap condition, treatment and final outcome. All Chinese publications relevant to late traumatic flap complications in Chinese patients were retrieved and summarised. 92 inpatients (92 eyes) underwent LASIK surgery; 45 of these had traumatic LASIK flap complications. Flap dislocation was the commonest and most needed surgical repair. VA after treatment was good and no statistically significant difference was observed when compared with the 47 cases without flap complications. 109 articles related to late traumatic flap complications after LASIK were retrieved from four Chinese document databases. There were 550 cases of late traumatic flap complications. From 2004, case reports became more common; 10 or more cases were reported in some case series. VA of most cases was good and there was no remarkable vision loss after treatment. Late traumatic flap complications after LASIK have become more frequent in China, although the prognosis of most cases is good. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Kobayashi, Tohru; Fuse, Shigeto; Sakamoto, Naoko; Mikami, Masashi; Ogawa, Shunichi; Hamaoka, Kenji; Arakaki, Yoshio; Nakamura, Tsuneyuki; Nagasawa, Hiroyuki; Kato, Taichi; Jibiki, Toshiaki; Iwashima, Satoru; Yamakawa, Masaru; Ohkubo, Takashi; Shimoyama, Shinya; Aso, Kentaro; Sato, Seiichi; Saji, Tsutomu
2016-08-01
Several coronary artery Z score models have been developed. However, a Z score model derived by the lambda-mu-sigma (LMS) method has not been established. Echocardiographic measurements of the proximal right coronary artery, left main coronary artery, proximal left anterior descending coronary artery, and proximal left circumflex artery were prospectively collected in 3,851 healthy children ≤18 years of age and divided into developmental and validation data sets. In the developmental data set, smooth curves were fitted for each coronary artery using linear, logarithmic, square-root, and LMS methods for both sexes. The relative goodness of fit of these models was compared using the Bayesian information criterion. The best-fitting model was tested for reproducibility using the validation data set. The goodness of fit of the selected model was visually compared with that of the previously reported regression models using a Q-Q plot. Because the internal diameter of each coronary artery was not similar between sexes, sex-specific Z score models were developed. The LMS model with body surface area as the independent variable showed the best goodness of fit; therefore, the internal diameter of each coronary artery was transformed into a sex-specific Z score on the basis of body surface area using the LMS method. In the validation data set, a Q-Q plot of each model indicated that the distribution of Z scores in the LMS models was closer to the normal distribution compared with previously reported regression models. Finally, the final models for each coronary artery in both sexes were developed using the developmental and validation data sets. A Microsoft Excel-based Z score calculator was also created, which is freely available online (http://raise.umin.jp/zsp/calculator/). Novel LMS models with which to estimate the sex-specific Z score of each internal coronary artery diameter were generated and validated using a large pediatric population. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Ashraf, Mohammed; Souka, Ahmed; Adelman, Ron A
2018-03-01
To assess predictors of treatment response in neovascular age-related macular degeneration (AMD) in an attempt to develop a patient-centric treatment algorithm. We conducted a systematic search using PubMed, EMBASE and Web of Science for prognostic indicators/predictive factors with the key words: 'age related macular degeneration', 'neovascular AMD', 'choroidal neovascular membrane (CNV)', 'anti-vascular endothelial growth factor (anti-VEGF)', 'aflibercept', 'ranibizumab', 'bevacizumab', 'randomized clinical trials', 'post-hoc', 'prognostic', 'predictive', 'response' 'injection frequency, 'treat and extend (TAE), 'pro re nata (PRN)', 'bi-monthly' and 'quarterly'. We only included studies that had an adequate period of follow-up (>1 year), a single predefined treatment regimen with a predetermined re-injection criteria, an adequate number of patients, specific morphological [optical coherence tomography (OCT)] criteria that predicted final visual outcomes and injection frequency and did not include switching from one drug to the other. We were able to identify seven prospective studies and 16 retrospective studies meeting our inclusion criteria. There are several morphological and demographic prognostic indicators that can predict response to therapy in wet AMD. Smaller CNV size, subretinal fluid (SRF), retinal angiomatous proliferation (RAP) and response to therapy at 12 weeks (visual, angiographic or OCT) can all predict good visual outcomes in patients receiving anti-VEGF therapy. Patients with larger CNV, older age, pigment epithelial detachment (PED), intraretinal cysts (IRC) and vitreomacular adhesion (VMA) achieved less visual gains. Patients having VMA/VMT required more intensive treatment with increased treatment frequency. Patients with both posterior vitreous detachment (PVD) and SRF require infrequent injections. Patients with PED are prone to recurrences of fluid activity with a reduction in visual acuity (VA). A regimen that involves less intensive therapy and extended follow-up intervals (4 weekly) can be suggested for patients who show adequate visual response and have both SRF and PVD at baseline. In addition, patients with poor prognostic indicators such as IRC, VMA, large CNV size, older age and poor response at 12 weeks should be extended very cautiously with the possibility of fixed monthly/bimonthly (every 2 months) treatments if they fail to achieve dryness. Patients with PED at baseline should receive monthly/bimonthly injections of anti-VEGF therapy or can be extended very cautiously (two weekly intervals) using a TAE protocol. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
SU-E-J-229: Magnetic Resonance Imaging of Small Fiducial Markers for Proton Beam Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Y; James, J; Panda, A
2015-06-15
Purpose: For proton beam therapy, small fiducial markers are preferred for patient alignment due to less interference with the proton beam. Visualizing small fiducial markers can be challenging in MRI. This study intends to investigate MRI imaging protocols for better visualization of small fiducial markers. Methods: Two carbon and two coil-shaped gold markers were placed into a gel phantom. Both carbon markers had a diameter of 1mm and a length of 3mm. Both gold markers had a length of 5mm. One gold marker had a diameter of 0.5mm and the other had a diameter of 0.75mm. T1 VIBE, T2 SPACE,more » TrueFISP and susceptibility weighted (SW) images were acquired. To improve marker contrast, high spatial resolution was used to reduce partial volume effect. Slice thickness was 1.5mm for all four sequences and in-plane resolution was 0.6mm for TrueFISP, 0.7mm for T1 VIBE, and 0.8mm for T2 SPACE and SW. For comparison purpose, a 3D T1 VIBE image set at 3mm slice thickness and 1.2mm in-plane resolution was also acquired. Results: All markers were visible in all high-resolution image sets. In each image set, marker-induced signal void was the smallest (in diameter) for carbon markers, followed by the 0.5mm gold marker and the largest for the 0.75mm gold marker. The SW images had the largest marker-induced signal void. However, those might be confused by susceptibility-gradient-induced signal voids. T1 VIBE had good visualization of markers with nicely defined edges. T2 SPACE had reasonable visualization of markers but edges were slightly blurred. TrueFISP had good visualization of markers only if they were not masked by banding artifacts. As a comparison, all markers were hardly visible in the standard resolution T1 VIBE images. Conclusion: 3D high-resolution T1 VIBE and SW have great potential in providing good visualization of small fiducial markers for proton beam therapy.« less
Reliability and validity of the Microsoft Kinect for evaluating static foot posture
2013-01-01
Background The evaluation of foot posture in a clinical setting is useful to screen for potential injury, however disagreement remains as to which method has the greatest clinical utility. An inexpensive and widely available imaging system, the Microsoft Kinect™, may possess the characteristics to objectively evaluate static foot posture in a clinical setting with high accuracy. The aim of this study was to assess the intra-rater reliability and validity of this system for assessing static foot posture. Methods Three measures were used to assess static foot posture; traditional visual observation using the Foot Posture Index (FPI), a 3D motion analysis (3DMA) system and software designed to collect and analyse image and depth data from the Kinect. Spearman’s rho was used to assess intra-rater reliability and concurrent validity of the Kinect to evaluate foot posture, and a linear regression was used to examine the ability of the Kinect to predict total visual FPI score. Results The Kinect demonstrated moderate to good intra-rater reliability for four FPI items of foot posture (ρ = 0.62 to 0.78) and moderate to good correlations with the 3DMA system for four items of foot posture (ρ = 0.51 to 0.85). In contrast, intra-rater reliability of visual FPI items was poor to moderate (ρ = 0.17 to 0.63), and correlations with the Kinect and 3DMA systems were poor (absolute ρ = 0.01 to 0.44). Kinect FPI items with moderate to good reliability predicted 61% of the variance in total visual FPI score. Conclusions The majority of the foot posture items derived using the Kinect were more reliable than the traditional visual assessment of FPI, and were valid when compared to a 3DMA system. Individual foot posture items recorded using the Kinect were also shown to predict a moderate degree of variance in the total visual FPI score. Combined, these results support the future potential of the Kinect to accurately evaluate static foot posture in a clinical setting. PMID:23566934
The Common Good in Classical Political Philosophy
ERIC Educational Resources Information Center
Lewis, V. Bradley
2006-01-01
The term "common good" names the end (or final cause) of political and social life in the tradition of moral thought that owes its main substance to Aristotle and St. Thomas Aquinas. It names a genuine good ("bonum honestum") and not merely an instrumental or secondary good defeasible in the face of particular goods. However, at the same time, it…
Hyvärinen, Lea
2007-01-01
Visual assessment of deaf persons presents a challenge to the ophthalmologist and the optometrist. At the time they want to measure visual function, the interpreter uses visual communication, competing for the patient's attention. Important rules of good assessment of visual functioning include taking turns and giving the interpreter sufficient time to convey the questions related to each test. This has implications for audiologists working with this population as well. Communication should be tailored to the varying needs of people who may have long-standing deafness and good sign language, may have lost their hearing at an advanced age and have limited or no sign language, or may be young persons or children who have congenital or progressive loss of hearing combined with congenital or progressive vision loss. Individuals with sudden hearing and vision loss, as well as those with intellectual disabilities and limited language, are particularly challenging groups for the assessment of vision and require special communication skills for ophthalmologists and audiologists. The ophthalmologist usually knows the nature of vision changes typical of disorders that the patient has. For the clinical follow-up of a condition, a few measurements are usually taken. For a comprehensive assessment of visual functioning for rehabilitation and education, many more measurements, observations, and questions are needed so that vision for communication, orientation in the environment, and performance of near-vision tasks can be reported and the effects of the environment can be evaluated. Testing should cover ocular disorders and vision loss caused by brain damage. PMID:18003866
NASA Astrophysics Data System (ADS)
Messerotti, M.
2009-04-01
Earth and Space Science research, as well as many other disciplines, can nowadays benefit from advanced data handling techniques and tools capable to significantly relieve the scientist of the burden of data search, retrieval, visualization and manipulation, and to exploit the data information content. Some typical examples are Virtual Observatories (VO) specific to a variety of sub-disciplines but anyway interlinked, a feature intrinsic to the VO architecture, Virtual Globes as advanced 3D selection and visualization interfaces to distributed data repositories, and the Global Earth Observation System of Systems. These information systems are proving also effective in education and outreach activities as they are usable via web interfaces to give access to, to display and to download nonhomogeneous datasets in order to raise the awareness of the students and the public on the relevant disciplines. Despite of that, all of this effective machineries are still poorly used both by the scientific community and by the community active in education and outreach. All such infrastructures are designed and developed according to the state-of-the-art information and computer engineering techniques and are provided with top features such as ontology- and semantics-based data management, and advanced unified web-based interfaces. Anyway, a careful analysis of the issue mentioned above indicates a key aspect that play a major role, i.e., the inadequate interaction with the users' communities during the design, the development, the deployment and the test phases. Even the best technical tool can appear inadequate to the final user when it does not meet the user's requirements in terms of achievable goals and use friendliness. In this work, we consider the user-side features to be taken into account for the optimum exploitation of an information system in the framework of the interaction among the design engineers and the target communities towards the setting of a good practice for minimizing the developer-user divide.
Yokoyama, Sho; Kojima, Takashi; Kaga, Tatsushi; Ichikawa, Kazuo
2015-01-01
We report three asteroid hyalosis cases in which internal higher-order aberrations (HOAs) were improved concomitant with improved visual symptoms after vitrectomy. Cases 1 and 2 reported severe floaters and glare disability, although their visual acuities were fairly good. Case 3 showed poor visual acuity since this patient also suffered from mild macular degeneration. For these three asteroid hyalosis cases, we were unsure if treatment with vitrectomy could improve visual symptoms. Therefore, we measured internal HOAs with an aberrometer, and found that the internal HOA values in these cases were high. We suspected that internal high HOAs values were associated with visual disturbance, and performed vitrectomy. After the vitrectomy, the internal HOA values in these three asteroid hyalosis cases markedly decreased, and visual symptoms improved. These observations suggested that measurement of internal HOAs may be useful to determine the indication for vitrectomy. PMID:26698200
Change blindness and visual memory: visual representations get rich and act poor.
Varakin, D Alexander; Levin, Daniel T
2006-02-01
Change blindness is often taken as evidence that visual representations are impoverished, while successful recognition of specific objects is taken as evidence that they are richly detailed. In the current experiments, participants performed cover tasks that required each object in a display to be attended. Change detection trials were unexpectedly introduced and surprise recognition tests were given for nonchanging displays. For both change detection and recognition, participants had to distinguish objects from the same basic-level category, making it likely that specific visual information had to be used for successful performance. Although recognition was above chance, incidental change detection usually remained at floor. These results help reconcile demonstrations of poor change detection with demonstrations of good memory because they suggest that the capability to store visual information in memory is not reflected by the visual system's tendency to utilize these representations for purposes of detecting unexpected changes.
Yokoyama, Sho; Kojima, Takashi; Kaga, Tatsushi; Ichikawa, Kazuo
2015-12-23
We report three asteroid hyalosis cases in which internal higher-order aberrations (HOAs) were improved concomitant with improved visual symptoms after vitrectomy. Cases 1 and 2 reported severe floaters and glare disability, although their visual acuities were fairly good. Case 3 showed poor visual acuity since this patient also suffered from mild macular degeneration. For these three asteroid hyalosis cases, we were unsure if treatment with vitrectomy could improve visual symptoms. Therefore, we measured internal HOAs with an aberrometer, and found that the internal HOA values in these cases were high. We suspected that internal high HOAs values were associated with visual disturbance, and performed vitrectomy. After the vitrectomy, the internal HOA values in these three asteroid hyalosis cases markedly decreased, and visual symptoms improved. These observations suggested that measurement of internal HOAs may be useful to determine the indication for vitrectomy. 2015 BMJ Publishing Group Ltd.
Visual Vestibular Interaction in the Dynamic Visual Acuity Test during Voluntary Head Rotation
NASA Technical Reports Server (NTRS)
Lee, Moo Hoon; Durnford, Simon; Crowley, John; Rupert, Angus
1996-01-01
Although intact vestibular function is essential in maintaining spatial orientation, no good screening tests of vestibular function are available to the aviation community. High frequency voluntary head rotation was selected as a vestibular stimulus to isolate the vestibulo-ocular reflex (VOR) from visual influence. A dynamic visual acuity test that incorporates voluntary head rotation was evaluated as a potential vestibular function screening tool. Twenty-seven normal subjects performed voluntary sinusoidal head rotation at frequencies from 0.7-4.0 Hz under three different visual conditions: visually-enhanced VOR, normal VOR, and visually suppressed VOR. Standardized Baily-Lovie chart letters were presented on a computer monitor in front of the subject, who then was asked to read the letters while rotating his head horizontally. The electro-oculogram and dynamic visual acuity score were recorded and analyzed. There were no significant differences in gain or phase shift among three visual conditions in the frequency range of 2.8 to 4.0 Hz. The dynamic visual acuity score shifted less than 0.3 logMAR at frequencies under 2.0 Hz. The dynamic visual acuity test at frequencies a round 2.0 Hz can be recommended for evaluating vestibular function.
Zheng, Cindy X; Moster, Marlene R; Khan, M Ali; Chiang, Allen; Garg, Sunir J; Dai, Yang; Waisbourd, Michael
2017-06-01
To report the clinical features, microbial spectrum, and treatment outcomes of endophthalmitis after glaucoma drainage implant (GDI) surgery. Records of patients diagnosed with endophthalmitis after GDI surgery were reviewed. Data on clinical course, microbiological laboratory results, and treatment were analyzed. Of 1,891 eyes that underwent GDI surgery, 14 eyes (0.7%) developed endophthalmitis. The mean time interval between GDI surgery and diagnosis of endophthalmitis was 2.6 ± 3.2 years (median, 1.3 years; range, 11 days-11.4 years). For initial treatment, 13/14 eyes underwent vitreous tap and injection of intravitreal antibiotics and 1/14 eyes underwent primary pars plana vitrectomy. Three additional eyes underwent pars plana vitrectomy because of deteriorating clinical course. Glaucoma drainage implant erosion was present in 9/14 eyes. All 9 eroded GDIs were surgically removed within a mean of 9 ± 5 days (range 2-29 days) after diagnosis of endophthalmitis. Overall, mean logarithm of the minimum angle of resolution best-corrected visual acuity worsened from 0.7 ± 0.7 (Snellen equivalent 20/100) at baseline to 1.6 ± 1.1 (Snellen equivalent 20/800) at final follow-up (P = 0.005). Mean duration between the onset of symptoms and presentation was significantly longer in patients with decreased final best-corrected visual acuity (>2 Snellen lines) compared to patients with stable final best-corrected visual acuity (6.8 vs. 1.0 days; P = 0.005). Glaucoma drainage implant-related endophthalmitis is rare and often associated with GDI erosion. Patients who presented earlier after the onset of symptoms had better final visual outcomes. Prompt evaluation and treatment is required, often with removal of the eroded GDI.
Cool Tools for the New Frontier: Technological Advances Help Associates Tell Their Story.
ERIC Educational Resources Information Center
Hersch, James
1998-01-01
Argues that creation of a World Wide Web site that makes good use of the available digital audio and visual technologies can be useful in campus activities planning and advertising. The design of a good Web site and the potential uses of digital video and compact discs are discussed. Costs of these technologies are also outlined. (MSE)
Visual dysfunction in Parkinson’s disease
Weil, Rimona S.; Schrag, Anette E.; Warren, Jason D.; Crutch, Sebastian J.; Lees, Andrew J.; Morris, Huw R.
2016-01-01
Patients with Parkinson’s disease have a number of specific visual disturbances. These include changes in colour vision and contrast sensitivity and difficulties with complex visual tasks such as mental rotation and emotion recognition. We review changes in visual function at each stage of visual processing from retinal deficits, including contrast sensitivity and colour vision deficits to higher cortical processing impairments such as object and motion processing and neglect. We consider changes in visual function in patients with common Parkinson’s disease-associated genetic mutations including GBA and LRRK2. We discuss the association between visual deficits and clinical features of Parkinson’s disease such as rapid eye movement sleep behavioural disorder and the postural instability and gait disorder phenotype. We review the link between abnormal visual function and visual hallucinations, considering current models for mechanisms of visual hallucinations. Finally, we discuss the role of visuo-perceptual testing as a biomarker of disease and predictor of dementia in Parkinson’s disease. PMID:27412389
Meyerhoff, Hauke S; Huff, Markus
2016-04-01
Human long-term memory for visual objects and scenes is tremendous. Here, we test how auditory information contributes to long-term memory performance for realistic scenes. In a total of six experiments, we manipulated the presentation modality (auditory, visual, audio-visual) as well as semantic congruency and temporal synchrony between auditory and visual information of brief filmic clips. Our results show that audio-visual clips generally elicit more accurate memory performance than unimodal clips. This advantage even increases with congruent visual and auditory information. However, violations of audio-visual synchrony hardly have any influence on memory performance. Memory performance remained intact even with a sequential presentation of auditory and visual information, but finally declined when the matching tracks of one scene were presented separately with intervening tracks during learning. With respect to memory performance, our results therefore show that audio-visual integration is sensitive to semantic congruency but remarkably robust against asymmetries between different modalities.
Wu, Lili; Gu, Ruolei; Zhang, Jianxin
2016-01-01
Attachment is critical to each individual. It affects the cognitive-affective processing of social information. The present study examines how attachment affects the processing of social information, specifically maternal information. We assessed the behavioral and electrophysiological responses to maternal information (compared to non-specific others) in a Go/No-go Association Task (GNAT) with 22 participants. The results illustrated that attachment affected maternal information processing during three sequential stages of information processing. First, attachment affected visual perception, reflected by enhanced P100 and N170 elicited by maternal information as compared to others information. Second, compared to others, mother obtained more attentional resources, reflected by faster behavioral response to maternal information and larger P200 and P300. Finally, mother was evaluated positively, reflected by shorter P300 latency in a mother + good condition as compared to a mother + bad condition. These findings indicated that the processing of attachment-relevant information is neurologically differentiated from other types of social information from an early stage of perceptual processing to late high-level processing.
Geometry definition and grid generation for a complete fighter aircraft
NASA Technical Reports Server (NTRS)
Edwards, T. A.
1986-01-01
Recent advances in computing power and numerical solution procedures have enabled computational fluid dynamicists to attempt increasingly difficult problems. In particular, efforts are focusing on computations of complex three-dimensional flow fields about realistic aerodynamic bodies. To perform such computations, a very accurate and detailed description of the surface geometry must be provided, and a three-dimensional grid must be generated in the space around the body. The geometry must be supplied in a format compatible with the grid generation requirements, and must be verified to be free of inconsistencies. This paper presents a procedure for performing the geometry definition of a fighter aircraft that makes use of a commercial computer-aided design/computer-aided manufacturing system. Furthermore, visual representations of the geometry are generated using a computer graphics system for verification of the body definition. Finally, the three-dimensional grids for fighter-like aircraft are generated by means of an efficient new parabolic grid generation method. This method exhibits good control of grid quality.
A framework for a decision support system for municipal solid waste landfill design.
Verge, Ashley; Rowe, R Kerry
2013-12-01
A decision support system (Landfill Advisor or LFAdvisor) was developed to integrate current knowledge of barrier systems into a computer application to assist in landfill design. The program was developed in Visual Basic and includes an integrated database to store information. LFAdvisor presents the choices available for each liner component (e.g. leachate collection system, geomembrane liner, clay liners) and provides advice on their suitability for different situations related to municipal solid waste landfills (e.g. final cover, base liner, lagoon liner). Unique to LFAdvisor, the service life of each engineered component is estimated based on results from the latest research. LFAdvisor considers the interactions between liner components, operating conditions, and the existing site environment. LFAdvisor can be used in the initial stage of design to give designers a good idea of what liner components will likely be required, while alerting them to issues that are likely to arise. A systems approach is taken to landfill design with the ultimate goal of maximising long-term performance and service life.
Geometry definition and grid generation for a complete fighter aircraft
NASA Technical Reports Server (NTRS)
Edwards, Thomas A.
1986-01-01
Recent advances in computing power and numerical solution procedures have enabled computational fluid dynamicists to attempt increasingly difficult problems. In particular, efforts are focusing on computations of complex three-dimensional flow fields about realistic aerodynamic bodies. To perform such computations, a very accurate and detailed description of the surface geometry must be provided, and a three-dimensional grid must be generated in the space around the body. The geometry must be supplied in a format compatible with the grid generation requirements, and must be verified to be free of inconsistencies. A procedure for performing the geometry definition of a fighter aircraft that makes use of a commercial computer-aided design/computer-aided manufacturing system is presented. Furthermore, visual representations of the geometry are generated using a computer graphics system for verification of the body definition. Finally, the three-dimensional grids for fighter-like aircraft are generated by means of an efficient new parabolic grid generation method. This method exhibits good control of grid quality.
Probing metamaterials with structured light
Xu, Yun; Sun, Jingbo; Walasik, Wiktor; ...
2016-11-03
Photonic metamaterials and metasurfaces are nanostructured optical materials engineered to enable properties that have not been found in nature. Optical characterization of these structures is a challenging task. We report a reliable technique that is particularly useful for characterization of phase properties introduced by small and spatially inhomogeneous samples of metamaterials and metasurfaces. The proposed structured light, or vortex based interferometric method is used to directly visualize phase changes introduced by subwavelength-thick nanostructures. In order to demonstrate the efficiency of the proposed technique, we designed and fabricated several metasurface samples consisting of metal nano-antennas introducing different phase shifts and experimentallymore » measured phase shifts of the transmitted light. The experimental results are in good agreement with numerical simulations and with the designed properties of the antenna arrays. Finally, due to the presence of the singularity in the vortex beam, one of the potential applications of the proposed approach based on structured light is step-by-step probing of small fractions of the micro-scale samples or images.« less
Early melanoma diagnosis with mobile imaging.
Do, Thanh-Toan; Zhou, Yiren; Zheng, Haitian; Cheung, Ngai-Man; Koh, Dawn
2014-01-01
We research a mobile imaging system for early diagnosis of melanoma. Different from previous work, we focus on smartphone-captured images, and propose a detection system that runs entirely on the smartphone. Smartphone-captured images taken under loosely-controlled conditions introduce new challenges for melanoma detection, while processing performed on the smartphone is subject to computation and memory constraints. To address these challenges, we propose to localize the skin lesion by combining fast skin detection and fusion of two fast segmentation results. We propose new features to capture color variation and border irregularity which are useful for smartphone-captured images. We also propose a new feature selection criterion to select a small set of good features used in the final lightweight system. Our evaluation confirms the effectiveness of proposed algorithms and features. In addition, we present our system prototype which computes selected visual features from a user-captured skin lesion image, and analyzes them to estimate the likelihood of malignance, all on an off-the-shelf smartphone.
Silva, D; Pereira, A M; Santos, N; Amaral, L; Delgado, L; Oude Elberink, J N; Coimbra, A
2017-05-01
A cross-cultural translation of the Vespid Allergy Quality of Life Questionnaire (VQLQ) to the Portuguese population (VQLQ-P) was performed, assessing its applicability in wasp and in non-beekeeper bee venom allergic patients. Additionally, we evaluated a Visual Analogue Scale (VAS) to estimate hymenoptera allergy interference with daily life. Methods. Cross-cultural translation was performed according to recommendations. The final VQLQ-P version, the Expectation of Outcome questionnaire (EoQ), EQ-5D and VAS were applied to wasp (n = 19) and non-beekeeper bee venom allergic patients (n = 30). Results. VQLQ-P significantly correlated with EoQ, (r = 0.76, p < 0.01), EQ-5D (usual activities and anxiety / depression dimensions) and VAS, with a good internal consistency (Cronbach α = 0.88) in wasp allergic individuals. VQLQ-P and EoQ correlation was also high (r = 0.67, p < 0.01) in bee allergy. Conclusion. The VQLQ-P is a valuable tool to evaluate quality of life impairment in Portuguese hymenoptera venom allergic individuals.
Nalavany, Blace Arthur; Carawan, Lena Williams; Rennick, Robyn A
2011-01-01
Concept mapping (a mixed qualitative-quantitative methodology) was used to describe and understand the psychosocial experiences of adults with confirmed and self-identified dyslexia. Using innovative processes of art and photography, Phase 1 of the study included 15 adults who participated in focus groups and in-depth interviews and were asked to elucidate their experiences with dyslexia. On index cards, 75 statements and experiences with dyslexia were recorded. The second phase of the study included 39 participants who sorted these statements into self-defined categories and rated each statement to reflect their personal experiences to produce a visual representation, or concept map, of their experience. The final concept map generated nine distinct cluster themes: Organization Skills for Success; Finding Success; A Good Support System Makes the Difference; On Being Overwhelmed; Emotional Downside; Why Can't They See It?; Pain, Hurt, and Embarrassment From Past to Present; Fear of Disclosure; and Moving Forward. Implications of these findings are discussed.
Evaluation of diagnostic accuracy in detecting ordered symptom statuses without a gold standard
Wang, Zheyu; Zhou, Xiao-Hua; Wang, Miqu
2011-01-01
Our research is motivated by 2 methodological problems in assessing diagnostic accuracy of traditional Chinese medicine (TCM) doctors in detecting a particular symptom whose true status has an ordinal scale and is unknown—imperfect gold standard bias and ordinal scale symptom status. In this paper, we proposed a nonparametric maximum likelihood method for estimating and comparing the accuracy of different doctors in detecting a particular symptom without a gold standard when the true symptom status had an ordered multiple class. In addition, we extended the concept of the area under the receiver operating characteristic curve to a hyper-dimensional overall accuracy for diagnostic accuracy and alternative graphs for displaying a visual result. The simulation studies showed that the proposed method had good performance in terms of bias and mean squared error. Finally, we applied our method to our motivating example on assessing the diagnostic abilities of 5 TCM doctors in detecting symptoms related to Chills disease. PMID:21209155
NASA Astrophysics Data System (ADS)
Unaldi, Numan; Asari, Vijayan K.; Rahman, Zia-ur
2009-05-01
Recently we proposed a wavelet-based dynamic range compression algorithm to improve the visual quality of digital images captured from high dynamic range scenes with non-uniform lighting conditions. The fast image enhancement algorithm that provides dynamic range compression, while preserving the local contrast and tonal rendition, is also a good candidate for real time video processing applications. Although the colors of the enhanced images produced by the proposed algorithm are consistent with the colors of the original image, the proposed algorithm fails to produce color constant results for some "pathological" scenes that have very strong spectral characteristics in a single band. The linear color restoration process is the main reason for this drawback. Hence, a different approach is required for the final color restoration process. In this paper the latest version of the proposed algorithm, which deals with this issue is presented. The results obtained by applying the algorithm to numerous natural images show strong robustness and high image quality.
Bedmap2; Mapping, visualizing and communicating the Antarctic sub-glacial environment.
NASA Astrophysics Data System (ADS)
Fretwell, Peter; Pritchard, Hamish
2013-04-01
Bedmap2; Mapping, visualizing and communicating the Antarctic sub-glacial environment. The Bedmap2 project has been a large cooperative effort to compile, model, map and visualize the ice-rock interface beneath the Antarctic ice sheet. Here we present the final output of that project; the Bedmap2 printed map. The map is an A1, double sided print, showing 2d and 3d visualizations of the dataset. It includes scientific interpretations, cross sections and comparisons with other areas. Paper copies of the colour double sided map will be freely distributed at this session.
Suggested Interactivity: Seeking Perceived Affordances for Information Visualization.
Boy, Jeremy; Eveillard, Louis; Detienne, Françoise; Fekete, Jean-Daniel
2016-01-01
In this article, we investigate methods for suggesting the interactivity of online visualizations embedded with text. We first assess the need for such methods by conducting three initial experiments on Amazon's Mechanical Turk. We then present a design space for Suggested Interactivity (i. e., visual cues used as perceived affordances-SI), based on a survey of 382 HTML5 and visualization websites. Finally, we assess the effectiveness of three SI cues we designed for suggesting the interactivity of bar charts embedded with text. Our results show that only one cue (SI3) was successful in inciting participants to interact with the visualizations, and we hypothesize this is because this particular cue provided feedforward.
Visual Masking in Schizophrenia: Overview and Theoretical Implications
Green, Michael F.; Lee, Junghee; Wynn, Jonathan K.; Mathis, Kristopher I.
2011-01-01
Visual masking provides several key advantages for exploring the earliest stages of visual processing in schizophrenia: it allows for control over timing at the millisecond level, there are several well-supported theories of the underlying neurobiology of visual masking, and it is amenable to examination by electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI). In this paper, we provide an overview of the visual masking impairment schizophrenia, including the relevant theoretical mechanisms for masking impairment. We will discuss its relationship to clinical symptoms, antipsychotic medications, diagnostic specificity, and presence in at-risk populations. As part of this overview, we will cover the neural correlates of visual masking based on recent findings from EEG and fMRI. Finally, we will suggest a possible mechanism that could explain the patterns of masking findings and other visual processing findings in schizophrenia. PMID:21606322
Visual Discrimination of Color Normals and Color Deficients. Final Report.
ERIC Educational Resources Information Center
Chen, Yih-Wen
Since visual discrimination is one of the factors involved in learning from instructional media, the present study was designed (1) to investigate the effects of hue contrast, illuminant intensity, brightness contrast, and viewing distance on the discrimination accuracy of those who see color normally and those who do not, and (2) to investigate…
Visual Tools for Eliciting Connections and Cohesiveness in Mixed Methods Research
ERIC Educational Resources Information Center
Murawska, Jaclyn M.; Walker, David A.
2017-01-01
In this commentary, we offer a set of visual tools that can assist education researchers, especially those in the field of mathematics, in developing cohesiveness from a mixed methods perspective, commencing at a study's research questions and literature review, through its data collection and analysis, and finally to its results. This expounds…
Bombs Away: Visual Thinking and Students' Engagement in Design Studios Contexts
ERIC Educational Resources Information Center
Chamorro-Koc, Marianella; Scott, Andrew; Coombs, Gretchen
2015-01-01
In design studio, sketching or visual thinking is part of processes that assist students to achieve final design solutions. At Queensland University of Technology's (QUT's) First and Third Year industrial design studio classes we engage in a variety of teaching pedagogies from which we identify "Concept Bombs" as instrumental in the…
Advanced Computer Image Generation Techniques Exploiting Perceptual Characteristics. Final Report.
ERIC Educational Resources Information Center
Stenger, Anthony J.; And Others
This study suggests and identifies computer image generation (CIG) algorithms for visual simulation that improve the training effectiveness of CIG simulators and identifies areas of basic research in visual perception that are significant for improving CIG technology. The first phase of the project entailed observing three existing CIG simulators.…
ERIC Educational Resources Information Center
Geri, George A.; Hubbard, David C.
Two adaptive psychophysical procedures (tracking and "yes-no" staircase) for obtaining human visual contrast sensitivity functions (CSF) were evaluated. The procedures were chosen based on their proven validity and the desire to evaluate the practical effects of stimulus transients, since tracking procedures traditionally employ gradual…
Age, School Experience and the Development of Visual-Perceptual Memory. Final Report, Part 2.
ERIC Educational Resources Information Center
Goulet, L. R.
This study attempted to investigate the effects of school experience on visual perception tests involving line figures and forms. There were two experiments in this study. Experiment 1 examined the independent and interactive influences of school experience and chronological age in kindergarten children. Experiment 2 compared the effects of…
Cicinelli, Maria Vittoria; Cavalleri, Michele; Querques, Lea; Rabiolo, Alessandro; Bandello, Francesco; Querques, Giuseppe
2017-12-01
To analyse the effects of intravitreal dexamethasone implant in patients suffering from diabetic macular oedema (DME) on the basis of their visual and functional response to antivascular endothelial growth factor (VEGF) loading dose, in order to early shift to corticosteroids in poorly responding patients. Retrospective monocentric study. Data of patients with diabetes shifted to 0.7 mg dexamethasone implant after three injections of ranibizumab (RNB) and followed-up to 12 months were reviewed. Main outcome was the evaluation of short-term changes after dexamethasone implant injection, stratifying patients on the basis of best-corrected visual acuity (BCVA) and central macular thickness (CMT) after RNB loading dose. Secondary outcome was to investigate clinical gain maintenance at long-term follow-up. Overall, 45 eyes of 45 patients (23 males, 51.1%), mean age 69.7±9 years, were included in the analysis. After 3 injections of RNB, 30 eyes (66.7%) had a poor visual response (-4.3±10.7 letters), while 15 eyes (33.3%) disclosed good visual outcome (+13.9±9.2 letters). Patients with poor visual response were associated with limited morphological improvement (p=0.04). After 1 month from dexamethasone, only poor responders showed relevant increase in BCVA (p=0.006) and reduction in CMT (p=0.002), in comparison to good visual response patients, featuring only minor clinical effects (p=0.3). The same trend was maintained up to 12 months, after a mean of 1.9±1.1 dexamethasone administrations. Visual and anatomical responses after RNB loading dose are significant predictors of both early term and long-term visual acuity improvement after switching to corticosteroids in patients with DME unresponsive to anti-VEGF. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Ganesh, Sri; Brar, Sheetal; Pawar, Archana
2017-01-01
Purpose To study the long-term visual and refractive outcomes and evaluate patient satisfaction after bilateral implantation of trifocal intraocular lenses (IOLs). Setting Nethradhama Superspeciality Eye Hospital, Bangalore. Design Prospective, nonrandomized study. Methods Eligible patients undergoing bilateral phacoemulsification with trifocal IOL implantation were included. Follow-up examinations were conducted at day 1, 1 week, 1 month, 6 months, and 12 months. Postoperatively, 1 month onward evaluation of uncorrected and distance-corrected far and near visual acuity; reading acuity and reading speeds (using Salzburg Reading Desk) at 70, 80, and 90 cm; contrast sensitivity; defocus curves; and patient satisfaction was carried out. Results Fifty eyes from 25 patients with a mean age of 58±13.44 years were included. All eyes showed significant improvement in spherical equivalent, uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, and corrected near visual acuity at 1 month compared to preoperative values (P<0.05), with no significant change in these parameters thereafter until the last follow-up (P>0.05). At 12 months, mean uncorrected reading acuities and reading speeds at 70, 80, and 90 cm were in the range of 0.09–0.04 logMAR units and 153.6–169.0 words per minute, respectively, with significantly better results at 80 cm. Five eyes underwent YAG laser capsulotomy for early posterior capsule opacification (PCO) at a mean follow-up of 7.2±2.9 months. Contrast sensitivity scores at 12 months were comparable to 1 month (P>0.05 for all spatial frequencies). All patients reported good tolerance and 100% independence from spectacles for all activities. Conclusion Trifocal IOLs provided excellent unaided vision at all distances. Reading performance was good through the complete intermediate distance range. PCO occurrence and subsequent YAG capsulotomy did not affect the long-term visual outcomes. PMID:28860693
Automated lobar quantification of emphysema in patients with severe COPD.
Revel, Marie-Pierre; Faivre, Jean-Baptiste; Remy-Jardin, Martine; Deken, Valérie; Duhamel, Alain; Marquette, Charles-Hugo; Tacelli, Nunzia; Bakai, Anne-Marie; Remy, Jacques
2008-12-01
Automated lobar quantification of emphysema has not yet been evaluated. Unenhanced 64-slice MDCT was performed in 47 patients evaluated before bronchoscopic lung-volume reduction. CT images reconstructed with a standard (B20) and high-frequency (B50) kernel were analyzed using a dedicated prototype software (MevisPULMO) allowing lobar quantification of emphysema extent. Lobar quantification was obtained following (a) a fully automatic delineation of the lobar limits by the software and (b) a semiautomatic delineation with manual correction of the lobar limits when necessary and was compared with the visual scoring of emphysema severity per lobe. No statistically significant difference existed between automated and semiautomated lobar quantification (p > 0.05 in the five lobes), with differences ranging from 0.4 to 3.9%. The agreement between the two methods (intraclass correlation coefficient, ICC) was excellent for left upper lobe (ICC = 0.94), left lower lobe (ICC = 0.98), and right lower lobe (ICC = 0.80). The agreement was good for right upper lobe (ICC = 0.68) and moderate for middle lobe (IC = 0.53). The Bland and Altman plots confirmed these results. A good agreement was observed between the software and visually assessed lobar predominance of emphysema (kappa 0.78; 95% CI 0.64-0.92). Automated and semiautomated lobar quantifications of emphysema are concordant and show good agreement with visual scoring.
Prevalence and Visual Outcomes of Cataract Surgery in Rural South India: A Cross-Sectional Study.
Paul, P; Kuriakose, T; John, J; Raju, R; George, K; Amritanand, A; Doss, P A; Muliyil, J
2016-10-01
To determine the prevalence of cataract surgery and postoperative vision-related outcomes, especially with respect to sex, socioeconomic status (SES) and site of first contact with eye care, in a rural area of South India. In a population-based cross-sectional survey of 5530 individuals aged 50 years or older from 10 villages selected by cluster sampling, individuals who had undergone cataract surgery in one or both eyes were identified. Consenting participants were administered a questionnaire, underwent vision assessment and ophthalmic examination. Outcomes were classified as good if visual acuity of the operated eye was 6/18 or better, fair if worse than 6/18 but better than or equal to 6/60, and poor if worse than 6/60. Prevalence of cataract surgery in this age group (771 persons) was 13.9% (95% confidence interval, CI, 13.0-14.9%). In the 1112 eyes of 749 persons studied, at presentation, 53.1% (95% CI 50.1-56.1%) of operated eyes had good, 38.1% (95% CI 35.2-41.0%) had fair, and 8.8% (95% CI 7.1-10.5%) had poor outcomes. With pinhole, 75.2% (95% CI 72.6-77.8%) had good, 17.2% (95% CI 14.9-19.5%) had fair, and 7.4% (95% CI 5.8-9.0%) had poor outcomes. In 76.3% of eyes with fair and poor presenting outcomes we detected an avoidable cause for the suboptimal visual acuity. Place of surgery and duration since surgery of 3 years or more were risk factors for blindness, while SES, sex and site of first eye care contact were not. The high prevalence of avoidable causes of visual impairment in this rural setting indicates the scope for preventive strategies.
Flight set 360L007 (STS-33) insulation component. Volume 3: Final release
NASA Technical Reports Server (NTRS)
Hicken, Steve
1990-01-01
Volume 3 of this postfire report deals with the insulation component of the RSRM. The report is released twice for each flight set. The interim release contract date is on or before 60 days after the last field joint or nozzle to case joint is disassembled at KSC and contain the results of the KSC visual evaluation. The data contained in Volume 3 interim release supersedes the insulation data presented in the KSC 10 day report. The final release contract data is on or before 60 days after the last factory joint is disassembled at the Clearfield H-7 facility and contains the results of all visual evaluations and a thermal safety factor analysis. The data contained in the Volume 3 final release supersedes the interim release and the insulation data presented in the Clearfield 10 day report.
We've been examining how to practically link ecosystems to human values. We have found that the concept "Final Ecosystem Goods and Services" (FEGS) is a useful way to make this linkage. FEGS are defined as ecological features people perceive as being directly relevant to their ...
Wheeler, David C.; Hickson, DeMarc A.; Waller, Lance A.
2010-01-01
Many diagnostic tools and goodness-of-fit measures, such as the Akaike information criterion (AIC) and the Bayesian deviance information criterion (DIC), are available to evaluate the overall adequacy of linear regression models. In addition, visually assessing adequacy in models has become an essential part of any regression analysis. In this paper, we focus on a spatial consideration of the local DIC measure for model selection and goodness-of-fit evaluation. We use a partitioning of the DIC into the local DIC, leverage, and deviance residuals to assess local model fit and influence for both individual observations and groups of observations in a Bayesian framework. We use visualization of the local DIC and differences in local DIC between models to assist in model selection and to visualize the global and local impacts of adding covariates or model parameters. We demonstrate the utility of the local DIC in assessing model adequacy using HIV prevalence data from pregnant women in the Butare province of Rwanda during 1989-1993 using a range of linear model specifications, from global effects only to spatially varying coefficient models, and a set of covariates related to sexual behavior. Results of applying the diagnostic visualization approach include more refined model selection and greater understanding of the models as applied to the data. PMID:21243121
Understanding geological processes: Visualization of rigid and non-rigid transformations
NASA Astrophysics Data System (ADS)
Shipley, T. F.; Atit, K.; Manduca, C. A.; Ormand, C. J.; Resnick, I.; Tikoff, B.
2012-12-01
Visualizations are used in the geological sciences to support reasoning about structures and events. Research in cognitive sciences offers insights into the range of skills of different users, and ultimately how visualizations might support different users. To understand the range of skills needed to reason about earth processes we have developed a program of research that is grounded in the geosciences' careful description of the spatial and spatiotemporal patterns associated with earth processes. In particular, we are pursuing a research program that identifies specific spatial skills and investigates whether and how they are related to each other. For this study, we focus on a specific question: Is there an important distinction in the geosciences between rigid and non-rigid deformation? To study a general spatial thinking skill we employed displays with non-geological objects that had been altered by rigid change (rotation), and two types of non-rigid change ("brittle" (or discontinuous) and "ductile" (or continuous) deformation). Disciplinary scientists (geosciences and chemistry faculty), and novices (non-science faculty and undergraduate psychology students) answered questions that required them to visualize the appearance of the object before the change. In one study, geologists and chemists were found to be superior to non-science faculty in reasoning about rigid rotations (e.g., what an object would look like from a different perspective). Geologists were superior to chemists in reasoning about brittle deformations (e.g., what an object looked like before it was broken - here the object was a word cut into many fragments displaced in different directions). This finding is consistent with two hypotheses: 1) Experts are good at visualizing the types of changes required for their domain; and 2) Visualization of rigid and non-rigid changes are not the same skill. An additional important finding is that there was a broad range of skill in both rigid and non-rigid reasoning within the panels of science experts. In a second study, individual differences in reasoning about brittle deformations were correlated with reasoning about ductile deformations (e.g., what a bent plastic sheet would look like when unbent). Students who were good at visualizing what something looked like before it was broken were also good at visualizing what something looked like before it was bent, and this skill was not correlated to reasoning about rigid rotations. These findings suggest the cognitive processes that support reasoning about rigid and non-rigid events may differ and thus may require different types of support and training. We do not know if differences between experts and novices result from experience or self-selection, or both. Nevertheless, the range of spatial skill evinced by novices and experts strongly argues for designing visualizations to support a variety of users.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beer, G K; Hendrix, J L; Rowe, J
1998-06-26
The stray light or "ghost" analysis of the National Ignition Facility's (NIP) Final Optics Assembly (FOA) has proved to be one of the most complex ghost analyses ever attempted. The NIF FOA consists of a bundle of four beam lines that: 1) provides the vacuum seal to the target chamber, 2) converts 1ω to 3ω light, 3) focuses the light on the target, 4) separates a fraction of the 3ω beam for energy diagnostics, 5) separates the three wavelengths to diffract unwanted 1ω & 2ω light away from the target, 6) provides spatial beam smoothing, and 7) provides a debrismore » barrier between the target chamber and the switchyard mirrors. The three wavelengths of light and seven optical elements with three diffractive optic surfaces generate three million ghosts through 4 th order. Approximately 24,000 of these ghosts have peak fluence exceeding 1 J/cm 2. The shear number of ghost paths requires a visualization method that allows overlapping ghosts on optics and mechanical components to be summed and then mapped to the optical and mechanical component surfaces in 3D space. This paper addresses the following aspects of the NIF Final Optics Ghost analysis: 1) materials issues for stray light mitigation, 2) limitations of current software tools (especially in modeling diffractive optics), 3) computer resource limitations affecting automated coherent raytracing, 4) folding the stray light analysis into the opto-mechanical design process, 5) analysis and visualization tools from simple hand calculations to specialized stray light analysis computer codes, and 6) attempts at visualizing these ghosts using a CAD model and another using a high end data visualization software approach.« less
Congdon, Nathan G; Krishnadas, R; Friedman, David S; Goggins, William; Ramakrishnan, R; Kader, M A; Gilbert, Donna; Tielsch, James; Quigley, Harry A
2012-06-01
To compare initial glaucoma therapy with medications and trabeculectomy in southern India. Patients aged ≥ 30 years newly diagnosed with glaucoma were randomized to trabeculectomy with 5-fluorouracil or medical therapy. Subjects with best-corrected vision <6/18 due to cataract underwent phacoemulsification (phaco/intraocular lens, IOL). Intraocular pressure (IOP), vision and visual function were assessed at 12 months. Patients assigned to medications and surgery received the expected therapy in 86% (172/199) and 64% (126/199) of cases, respectively. Forty patients (20%) assigned to surgery refused any treatment and 33 (17%) received medications. Among 199 patients randomized to medications, 52 (26.1%) underwent phaco/IOL, as did 89/199 (43.7%) of patients randomized to trabeculectomy. Baseline parameters of the two groups did not differ, nor did 1-year follow-up rates (medication 65%, trabeculectomy 58%, P = 0.15). Final IOP was lower with randomization to trabeculectomy (16.3 ± 5.1 mmHg) than medication (18.8 ± 6.7 mmHg, P < 0.0001). In regression models, randomization to trabeculectomy (P < 0.0001) was associated with lower IOP, and simultaneous trabeculectomy and cataract surgery was associated with higher IOP (P = 0.008) than trabeculectomy alone. Subjects receiving Phaco/IOL had significantly better final acuity (P < 0.0001) and visual function (P = 0.035), despite concurrent glaucoma treatment. Final visual acuity was worse in those receiving trabeculectomy in addition to cataract surgery, but this was of borderline significance (P = 0.06). Trabeculectomy lowered IOP significantly more than medical treatment, but with slightly greater loss of visual acuity. Combined phaco/IOL and trabeculectomy improved visual acuity with substantial IOP lowering.
Shon, Min Soo; Koh, Kyoung Hwan; Lim, Tae Kang; Kim, Won Ju; Kim, Kyung Cheon; Yoo, Jae Chul
2015-08-01
Arthroscopic partial repair is a treatment option in irreparable large-to-massive rotator cuff tears without arthritic changes. However, there are indications that arthroscopic partial repair does not yield satisfactory outcomes. To report the clinical and radiographic results of arthroscopic partial repairs in patients with irreparable large-to-massive cuff tears. In addition, an analysis was performed regarding preoperative factors that may influence patient outcomes and patient-rated satisfaction over time. Case series; Level of evidence, 4. From 2005 to 2011, a total of 31 patients who underwent arthroscopic partial repair for irreparable large-to-massive cuff tears were retrospectively evaluated. Partial repair was defined as posterior cuff tissue repair with or without subscapularis tendon repair to restore the transverse force couple of the cuff. Pain visual analog scale (PVAS), questionnaire results (American Shoulder and Elbow Surgeons [ASES] and Simple Shoulder Test [SST]), and radiographic changes (acromiohumeral distance and degenerative change) were assessed preoperatively, at first follow-up (roughly 1 year postoperatively), and at final follow-up (>2 years postoperatively). Patients rated their satisfaction level at each postoperative follow-up as well. Preoperative factors that might influence outcomes, such as patient demographics, tear size, and fatty infiltration, were investigated. The preoperative, first follow-up, and final follow-up results for mean PVAS (5.13, 2.13, and 3.16, respectively) and questionnaires (ASES: 41.97, 76.37, and 73.78; SST: 3.61, 6.33, and 6.07, respectively) improved significantly (all P < .05). Radiographic evaluation showed no difference compared with preoperative status. Nevertheless, patient-rated satisfaction at final evaluation was inferior: 16 good responses ("very satisfied" and "satisfied") and 15 poor responses ("rather the same" and "dissatisfied"). Despite initial improvements in both groups (P < .05), patients with poor satisfaction demonstrated statistically significant deterioration in mean PVAS (from 2.07 to 4.67), questionnaire scores (ASES: from 74.56 to 59.80; SST: from 5.11 to 3.81), and acromiohumeral distance (from 7.19 to 5.06 mm) between the first and final follow-up (all P < .05). Patients with good satisfaction showed no significant difference or they improved (P > .05) from the first to the final follow-up. Among preoperative factors, fatty infiltration of the teres minor was identified as the only statistically significant factor affecting patient-rated satisfaction (P = .007). This study showed that arthroscopic partial repair may produce initial improvement in selected outcomes at 2-year follow-up. However, about half of the patients in the study were not satisfied with their outcomes, which had deteriorated over time. Preoperative fatty infiltration of the teres minor was the only factor that correlated with worse final outcomes and poor satisfaction after arthroscopic partial repair. © 2015 The Author(s).
Bellocchi, Stéphanie; Muneaux, Mathilde; Huau, Andréa; Lévêque, Yohana; Jover, Marianne; Ducrot, Stéphanie
2017-08-01
Reading is known to be primarily a linguistic task. However, to successfully decode written words, children also need to develop good visual-perception skills. Furthermore, motor skills are implicated in letter recognition and reading acquisition. Three studies have been designed to determine the link between reading, visual perception, and visual-motor integration using the Developmental Test of Visual Perception version 2 (DTVP-2). Study 1 tests how visual perception and visual-motor integration in kindergarten predict reading outcomes in Grade 1, in typical developing children. Study 2 is aimed at finding out if these skills can be seen as clinical markers in dyslexic children (DD). Study 3 determines if visual-motor integration and motor-reduced visual perception can distinguish DD children according to whether they exhibit or not developmental coordination disorder (DCD). Results showed that phonological awareness and visual-motor integration predicted reading outcomes one year later. DTVP-2 demonstrated similarities and differences in visual-motor integration and motor-reduced visual perception between children with DD, DCD, and both of these deficits. DTVP-2 is a suitable tool to investigate links between visual perception, visual-motor integration and reading, and to differentiate cognitive profiles of children with developmental disabilities (i.e. DD, DCD, and comorbid children). Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Looking for an accident: glider pilots' visual management and potentially dangerous final turns.
Jarvis, Steve; Harris, Don
2007-06-01
Accidents caused by spinning from low turns continue to kill glider pilots despite the introduction of specific exercises aimed at increasing pilot awareness and recognition of this issue. In-cockpit video cameras were used to analyze flying accuracy and log the areas of visual interest of 36 qualified glider pilots performing final turns in a training glider. Pilots were found to divide their attention between four areas of interest: the view directly ahead; the landing area (right); the airspeed indicator; and an area between the direct ahead view and the landing area. The mean fixation rate was 85 shifts per minute. Significant correlations were found between over-use of rudder and a lack of attention to the view ahead, as well as between the overall fixation rate and poorer coordination in the turn. The results provide some evidence that a relationship exists between pilots' visual management and making turns in a potentially dangerous manner. Pilots who monitor the view ahead for reasonable periods during the final turn while not allowing their scan to become over-busy are those who are most likely to prevent a potential spin.
Fung, David C Y; Wilkins, Marc R; Hart, David; Hong, Seok-Hee
2010-07-01
The force-directed layout is commonly used in computer-generated visualizations of protein-protein interaction networks. While it is good for providing a visual outline of the protein complexes and their interactions, it has two limitations when used as a visual analysis method. The first is poor reproducibility. Repeated running of the algorithm does not necessarily generate the same layout, therefore, demanding cognitive readaptation on the investigator's part. The second limitation is that it does not explicitly display complementary biological information, e.g. Gene Ontology, other than the protein names or gene symbols. Here, we present an alternative layout called the clustered circular layout. Using the human DNA replication protein-protein interaction network as a case study, we compared the two network layouts for their merits and limitations in supporting visual analysis.
Kumar, Parameet; Nath, Kapili; Rath, Bimba; Sen, Manas K; Vishalakshi, Potharuju; Chauhan, Devender S; Katoch, Vishwa M; Singh, Sarman; Tyagi, Sanjay; Sreenivas, Vishnubhatla; Prasad, Hanumanthappa K
2009-09-01
A real-time polymerase chain reaction (PCR) assay for the direct identification of Mycobacterium tuberculosis and M. bovis using molecular beacons was developed. The assay was modified for use in regular thermal cyclers. Molecular beacons that were specific for M. tuberculosis (Tb-B) and M. bovis (Bo-B) were designed. The fluorescence of the target PCR product-molecular beacon probe complex was detected visually using a transilluminator. The results were then compared with those of conventional multiplex PCR (CM-PCR) assays and biochemical identification. The detection limit of Tb-B and Bo-B beacons was 500 fg and 50 fg by the visual format and real-time PCR assay, respectively, compared with 5 pg by CM-PCR assay. Pulmonary and extrapulmonary samples were examined. The agreement between culture and the two assays was very good in sputum samples and fair in extrapulmonary samples. The agreement between clinical diagnoses with the two assays was moderate in extrapulmonary samples. There was very good agreement between CM-PCR and visual format assays for all samples used in the study. Concordance in the identification of isolates by the visual, CM-PCR assay, and biochemical identification was seen. Hence, the use of molecular beacon detection of M. tuberculosis and M. bovis in clinical samples is feasible by setting up two asymmetric PCRs concurrently. The assay is sensitive, specific, simple to interpret, and takes less than 3 hours to complete.
Kumar, Parameet; Nath, Kapili; Rath, Bimba; Sen, Manas K.; Vishalakshi, Potharuju; Chauhan, Devender S.; Katoch, Vishwa M.; Singh, Sarman; Tyagi, Sanjay; Sreenivas, Vishnubhatla; Prasad, Hanumanthappa K.
2009-01-01
A real-time polymerase chain reaction (PCR) assay for the direct identification of Mycobacterium tuberculosis and M. bovis using molecular beacons was developed. The assay was modified for use in regular thermal cyclers. Molecular beacons that were specific for M. tuberculosis (Tb-B) and M. bovis (Bo-B) were designed. The fluorescence of the target PCR product-molecular beacon probe complex was detected visually using a transilluminator. The results were then compared with those of conventional multiplex PCR (CM-PCR) assays and biochemical identification. The detection limit of Tb-B and Bo-B beacons was 500 fg and 50 fg by the visual format and real-time PCR assay, respectively, compared with 5 pg by CM-PCR assay. Pulmonary and extrapulmonary samples were examined. The agreement between culture and the two assays was very good in sputum samples and fair in extrapulmonary samples. The agreement between clinical diagnoses with the two assays was moderate in extrapulmonary samples. There was very good agreement between CM-PCR and visual format assays for all samples used in the study. Concordance in the identification of isolates by the visual, CM-PCR assay, and biochemical identification was seen. Hence, the use of molecular beacon detection of M. tuberculosis and M. bovis in clinical samples is feasible by setting up two asymmetric PCRs concurrently. The assay is sensitive, specific, simple to interpret, and takes less than 3 hours to complete. PMID:19661384
Li, Jingjing; Li, Jinrong; Chen, Zidong; Liu, Jing; Yuan, Junpeng; Cai, Xiaoxiao; Deng, Daming; Yu, Minbin
2017-01-01
We investigate the efficacy of a novel dichoptic mapping paradigm in evaluating visual function of anisometropic amblyopes. Using standard clinical measures of visual function (visual acuity, stereo acuity, Bagolini lenses, and neutral density filters) and a novel quantitative mapping technique, 26 patients with anisometropic amblyopia (mean age = 19.15 ± 4.42 years) were assessed. Two additional psychophysical interocular suppression measurements were tested with dichoptic global motion coherence and binocular phase combination tasks. Luminance reduction was achieved by placing neutral density filters in front of the normal eye. Our study revealed that suppression changes across the central 10° visual field by mean luminance modulation in amblyopes as well as normal controls. Using simulation and an elimination of interocular suppression, we identified a novel method to effectively reflect the distribution of suppression in anisometropic amblyopia. Additionally, the new quantitative mapping technique was in good agreement with conventional clinical measures, such as interocular acuity difference (P < 0.001) and stereo acuity (P = 0.005). There was a good consistency between the results of interocular suppression with dichoptic mapping paradigm and the results of the other two psychophysical methods (suppression mapping versus binocular phase combination, P < 0.001; suppression mapping versus global motion coherence, P = 0.005). The dichoptic suppression mapping technique is an effective method to represent impaired visual function in patients with anisometropic amblyopia. It offers a potential in "micro-"antisuppression mapping tests and therapies for amblyopia.
Zhang, Chunxia; Dang, Guangfu; Zhao, Tianmei; Wang, DongLin; Su, Yan; Qu, Yi
2018-04-12
To observe spectral-domain optical coherence tomography (SD-OCT) features and to determine whether baseline OCT features can be used as predictors of visual acuity outcome in eyes with acute welding arc maculopathy. This retrospective study enrolled twenty-two eyes of eleven subjects with acute welding arc maculopathy. All subjects were evaluated by SD-OCT at baseline and final visit. The involved parameters included best-corrected visual acuity (BCVA), central macular thickness (CMT), the length of ellipsoid zone (EZ) defects, the greatest linear dimension (GLD) of outer retinal lesions, EZ reflectivity and relative EZ reflectivity (defined as the ratio of EZ reflectivity to retinal pigment epithelium reflectivity on OCT). Acute welding arc maculopathy was presented as abnormal hyperreflectivity, hyporeflectivity and defects of outer retinal layer in fovea on OCT. Compared with baseline, BCVA improved significantly accompanied by decreased GLD of outer retinal lesions and the length of EZ defects at final visit (P = 0.0004, P < 0.0001 and P < 0.0001, respectively). No significant changes were shown on CMT (P = 0.248). In multivariate regression analysis, final BCVA was associated with baseline BCVA and the length of EZ defects (P = 0.012 and P = 0.045, respectively). However, EZ reflectivity and relative EZ reflectivity were not associated with final BCVA (P > 0.05). In conclusion, SD-OCT images clearly reveal morphological changes in outer retinal layer in acute welding arc maculopathy. The baseline BCVA and length of EZ defects are the strongest predictors of final BCVA.
ERIC Educational Resources Information Center
Reeder, Kevin
2005-01-01
In order to facilitate the selection/prioritization process and bridge the gap of design research to design conceptualization, students need to visualize the big picture that describes how the research categories such as "user," "marketing," "functional/mechanical research" are related. This is achieved through the use of a visual storyboard. The…
Unlocking User-Centered Design Methods for Building Cyber Security Visualizations
2015-10-03
a final, deployed tool. Goodall et al. interviewed analysts to derive requirements for a network security tool [14], while Stoll et al. explain the...4673-7599-3/15/$31.00 c©2015 IEEE 2015 IEEE SYMPOSIUM ON VISUALIZATION FOR CYBER SECURITY (VIZSEC) [14] J. R. Goodall , A. A. Ozok, W. G. Lutters, P...Visualization for Cyber Security, pages 91–98. IEEE, 2005. [19] A. Komlodi, P. Rheingans, U. Ayachit, J. Goodall , and A. Joshi. A user- centered look at
Procedures for precap visual inspection
NASA Technical Reports Server (NTRS)
1984-01-01
Screening procedures for the final precap visual inspection of microcircuits used in electronic system components are described as an aid in training personnel unfamiliar with microcircuits. Processing techniques used in industry for the manufacture of monolithic and hybrid components are presented and imperfections that may be encountered during this inspection are discussed. Problem areas such as scratches, voids, adhesions, and wire bonding are illustrated by photomicrographs. This guide can serve as an effective tool in training personnel to perform precap visual inspections efficiently and reliably.
Morita, Shigemichi; Takahashi, Toshiya; Yoshida, Yasushi; Yokota, Naohisa
2016-04-01
Hydroxychloroquine (HCQ) is an effective treatment for patients with cutaneous lupus erythematosus (CLE) or systemic lupus erythematosus (SLE) and has been used for these patients in more than 70 nations. However, in Japan, HCQ has not been approved for CLE or SLE. To establish an appropriate therapeutic regimen and to clarify the pharmacokinetics (PK) of HCQ in Japanese patients with CLE with or without SLE (CLE/SLE), a population pharmacokinetic (PopPK) analysis was performed. In a clinical study of Japanese patients with a diagnosis of CLE irrespective of the presence of SLE, blood and plasma drug concentration-time data receiving multiple oral doses of HCQ sulfate (200-400 mg daily) were analyzed using nonlinear mixed-effects model software. The blood and plasma concentrations of HCQ were analyzed using a high-performance liquid chromatography tandem mass spectrometry method. Model evaluation and validation were performed using goodness-of-fit (GOF) plots, visual predictive check, and a bootstrap. The PopPKs of HCQ in the blood and plasma of 90 Japanese patients with CLE/SLE were well described by a 1-compartment model with first-order absorption and absorption lag time. Body weight was a significant (P < 0.001) covariate of oral clearance of HCQ. The final model was assessed using GOF plots, a bootstrap, and visual predictive check, and this model was appropriate. Simulations based on the final model suggested that the recommended daily doses of HCQ sulfate (200-400 mg) based on the ideal body weight in Japanese patients with CLE/SLE were in the similar concentration ranges. The PopPK models derived from both blood and plasma HCQ concentrations of Japanese patients with CLE/SLE were developed and validated. Based on this study, the dosage regimens of HCQ sulfate for Japanese patients with CLE/SLE should be calculated using the individual ideal body weight.
Sadeh, Morteza; Sajad, Amirsaman; Wang, Hongying; Yan, Xiaogang; Crawford, John Douglas
2015-12-01
We previously reported that visuomotor activity in the superior colliculus (SC)--a key midbrain structure for the generation of rapid eye movements--preferentially encodes target position relative to the eye (Te) during low-latency head-unrestrained gaze shifts (DeSouza et al., 2011). Here, we trained two monkeys to perform head-unrestrained gaze shifts after a variable post-stimulus delay (400-700 ms), to test whether temporally separated SC visual and motor responses show different spatial codes. Target positions, final gaze positions and various frames of reference (eye, head, and space) were dissociated through natural (untrained) trial-to-trial variations in behaviour. 3D eye and head orientations were recorded, and 2D response field data were fitted against multiple models by use of a statistical method reported previously (Keith et al., 2009). Of 60 neurons, 17 showed a visual response, 12 showed a motor response, and 31 showed both visual and motor responses. The combined visual response field population (n = 48) showed a significant preference for Te, which was also preferred in each visual subpopulation. In contrast, the motor response field population (n = 43) showed a preference for final (relative to initial) gaze position models, and the Te model was statistically eliminated in the motor-only population. There was also a significant shift of coding from the visual to motor response within visuomotor neurons. These data confirm that SC response fields are gaze-centred, and show a target-to-gaze transformation between visual and motor responses. Thus, visuomotor transformations can occur between, and even within, neurons within a single frame of reference and brain structure. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Aji, Wijayanto Setyo; Purwanto; Suherman, S.
2018-02-01
Cassava starch industry is one of the leading small-medium enterprises (SMEs) in Pati Regency. Cassava starch industry released waste that reduces the quantity of final product and potentially contamined the environment. This study was conducted to observe the feasibility of good housekeeping implementation to reduce waste and at the same time improve efficiency of production process. Good housekeeping opportunities are consideration by three aspect, technical, economy and environmental. Good housekeeping opportunities involved water conservation and waste reduction. These included reuse of water in washing process, improving workers awareness in drying section and packaging section. Implementation of these opportunities can reduce water consumption, reduce wastewater and solid waste generation also increased quantity of final product.
ParaView visualization of Abaqus output on the mechanical deformation of complex microstructures
NASA Astrophysics Data System (ADS)
Liu, Qingbin; Li, Jiang; Liu, Jie
2017-02-01
Abaqus® is a popular software suite for finite element analysis. It delivers linear and nonlinear analyses of mechanical and fluid dynamics, includes multi-body system and multi-physics coupling. However, the visualization capability of Abaqus using its CAE module is limited. Models from microtomography have extremely complicated structures, and datasets of Abaqus output are huge, requiring a visualization tool more powerful than Abaqus/CAE. We convert Abaqus output into the XML-based VTK format by developing a Python script and then using ParaView to visualize the results. Such capabilities as volume rendering, tensor glyphs, superior animation and other filters allow ParaView to offer excellent visualizing manifestations. ParaView's parallel visualization makes it possible to visualize very big data. To support full parallel visualization, the Python script achieves data partitioning by reorganizing all nodes, elements and the corresponding results on those nodes and elements. The data partition scheme minimizes data redundancy and works efficiently. Given its good readability and extendibility, the script can be extended to the processing of more different problems in Abaqus. We share the script with Abaqus users on GitHub.
Reproduction of auditory and visual standards in monochannel cochlear implant users.
Kanabus, Magdalena; Szelag, Elzbieta; Kolodziejczyk, Iwona; Szuchnik, Joanna
2004-01-01
The temporal reproduction of standard durations ranging from 1 to 9 seconds was investigated in monochannel cochlear implant (CI) users and in normally hearing subjects for the auditory and visual modality. The results showed that the pattern of performance in patients depended on their level of auditory comprehension. Results for CI users, who displayed relatively good auditory comprehension, did not differ from that of normally hearing subjects for both modalities. Patients with poor auditory comprehension significantly overestimated shorter auditory standards (1, 1.5 and 2.5 s), compared to both patients with good comprehension and controls. For the visual modality the between-group comparisons were not significant. These deficits in the reproduction of auditory standards were explained in accordance with both the attentional-gate model and the role of working memory in prospective time judgment. The impairments described above can influence the functioning of the temporal integration mechanism that is crucial for auditory speech comprehension on the level of words and phrases. We postulate that the deficits in time reproduction of short standards may be one of the possible reasons for poor speech understanding in monochannel CI users.
Teaching oral hygiene to children with autism.
Pilebro, C; Bäckman, B
2005-01-01
The need for improved oral hygiene routines in individuals with disabilities has been documented in many reports. The aim of this study was to evaluate whether visual pedagogy is a suitable way to teach children with autism how to brush their teeth. The investigation took the form of a prospective study including clinical examinations and structured interviews. Based on visual pedagogy, a series of pictures were produced that showed a structured method and technique of tooth brushing. The pictures were placed in the bathroom or wherever tooth brushing was performed. Fourteen children with autism aged between 5 and 13 years (mean age = 9.3 years), and their parents participated. Before the study, all parents found it difficult/very difficult to maintain good oral hygiene in their child. All children had visible plaque on their maxillary incisors and canines. After 12 months, the amount of visible plaque was reduced. After 18 months, most parents found maintaining good oral hygiene easier than before the study. All but one child/parent adopted the programme. Visual pedagogy is a useful tool in helping people with autism to improve their oral hygiene.
Olivers, Christian N L; Meijer, Frank; Theeuwes, Jan
2006-10-01
In 7 experiments, the authors explored whether visual attention (the ability to select relevant visual information) and visual working memory (the ability to retain relevant visual information) share the same content representations. The presence of singleton distractors interfered more strongly with a visual search task when it was accompanied by an additional memory task. Singleton distractors interfered even more when they were identical or related to the object held in memory, but only when it was difficult to verbalize the memory content. Furthermore, this content-specific interaction occurred for features that were relevant to the memory task but not for irrelevant features of the same object or for once-remembered objects that could be forgotten. Finally, memory-related distractors attracted more eye movements but did not result in longer fixations. The results demonstrate memory-driven attentional capture on the basis of content-specific representations. Copyright 2006 APA.
Interactive Visualization of Complex Seismic Data and Models Using Bokeh
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chai, Chengping; Ammon, Charles J.; Maceira, Monica
Visualizing multidimensional data and models becomes more challenging as the volume and resolution of seismic data and models increase. But thanks to the development of powerful and accessible computer systems, a model web browser can be used to visualize complex scientific data and models dynamically. In this paper, we present four examples of seismic model visualization using an open-source Python package Bokeh. One example is a visualization of a surface-wave dispersion data set, another presents a view of three-component seismograms, and two illustrate methods to explore a 3D seismic-velocity model. Unlike other 3D visualization packages, our visualization approach has amore » minimum requirement on users and is relatively easy to develop, provided you have reasonable programming skills. Finally, utilizing familiar web browsing interfaces, the dynamic tools provide us an effective and efficient approach to explore large data sets and models.« less
Relating Standardized Visual Perception Measures to Simulator Visual System Performance
NASA Technical Reports Server (NTRS)
Kaiser, Mary K.; Sweet, Barbara T.
2013-01-01
Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).
Interactive Visualization of Complex Seismic Data and Models Using Bokeh
Chai, Chengping; Ammon, Charles J.; Maceira, Monica; ...
2018-02-14
Visualizing multidimensional data and models becomes more challenging as the volume and resolution of seismic data and models increase. But thanks to the development of powerful and accessible computer systems, a model web browser can be used to visualize complex scientific data and models dynamically. In this paper, we present four examples of seismic model visualization using an open-source Python package Bokeh. One example is a visualization of a surface-wave dispersion data set, another presents a view of three-component seismograms, and two illustrate methods to explore a 3D seismic-velocity model. Unlike other 3D visualization packages, our visualization approach has amore » minimum requirement on users and is relatively easy to develop, provided you have reasonable programming skills. Finally, utilizing familiar web browsing interfaces, the dynamic tools provide us an effective and efficient approach to explore large data sets and models.« less
Image communication scheme based on dynamic visual cryptography and computer generated holography
NASA Astrophysics Data System (ADS)
Palevicius, Paulius; Ragulskis, Minvydas
2015-01-01
Computer generated holograms are often exploited to implement optical encryption schemes. This paper proposes the integration of dynamic visual cryptography (an optical technique based on the interplay of visual cryptography and time-averaging geometric moiré) with Gerchberg-Saxton algorithm. A stochastic moiré grating is used to embed the secret into a single cover image. The secret can be visually decoded by a naked eye if only the amplitude of harmonic oscillations corresponds to an accurately preselected value. The proposed visual image encryption scheme is based on computer generated holography, optical time-averaging moiré and principles of dynamic visual cryptography. Dynamic visual cryptography is used both for the initial encryption of the secret image and for the final decryption. Phase data of the encrypted image are computed by using Gerchberg-Saxton algorithm. The optical image is decrypted using the computationally reconstructed field of amplitudes.
Visual perceptual load induces inattentional deafness.
Macdonald, James S P; Lavie, Nilli
2011-08-01
In this article, we establish a new phenomenon of "inattentional deafness" and highlight the level of load on visual attention as a critical determinant of this phenomenon. In three experiments, we modified an inattentional blindness paradigm to assess inattentional deafness. Participants made either a low- or high-load visual discrimination concerning a cross shape (respectively, a discrimination of line color or of line length with a subtle length difference). A brief pure tone was presented simultaneously with the visual task display on a final trial. Failures to notice the presence of this tone (i.e., inattentional deafness) reached a rate of 79% in the high-visual-load condition, significantly more than in the low-load condition. These findings establish the phenomenon of inattentional deafness under visual load, thereby extending the load theory of attention (e.g., Lavie, Journal of Experimental Psychology. Human Perception and Performance, 25, 596-616, 1995) to address the cross-modal effects of visual perceptual load.
GLO-STIX: Graph-Level Operations for Specifying Techniques and Interactive eXploration
Stolper, Charles D.; Kahng, Minsuk; Lin, Zhiyuan; Foerster, Florian; Goel, Aakash; Stasko, John; Chau, Duen Horng
2015-01-01
The field of graph visualization has produced a wealth of visualization techniques for accomplishing a variety of analysis tasks. Therefore analysts often rely on a suite of different techniques, and visual graph analysis application builders strive to provide this breadth of techniques. To provide a holistic model for specifying network visualization techniques (as opposed to considering each technique in isolation) we present the Graph-Level Operations (GLO) model. We describe a method for identifying GLOs and apply it to identify five classes of GLOs, which can be flexibly combined to re-create six canonical graph visualization techniques. We discuss advantages of the GLO model, including potentially discovering new, effective network visualization techniques and easing the engineering challenges of building multi-technique graph visualization applications. Finally, we implement the GLOs that we identified into the GLO-STIX prototype system that enables an analyst to interactively explore a graph by applying GLOs. PMID:26005315
Utilization and Organization of Visually Presented Information. Final Report.
ERIC Educational Resources Information Center
Dick, A. O.
The experiments discussed in this report do not have a direct relationship to each other but represent work on a series of sub-issues within the general framework of visual processing of information. Because of this discreteness, the report is organized into a series of papers. The first is a general review of tachistoscopic work on iconic memory…
ERIC Educational Resources Information Center
Baldwin, Thomas F.
Man seems unable to retain different information from different senses or channels simultaneously; one channel gains full attention. However, it is hypothesized that if the message elements arriving simultaneously from audio and visual channels are redundant, man will retain the information. An attempt was made to measure redundancy in the audio…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borovetz, H.S.; Shaffer, F.; Schaub, R.
This paper discusses a series of experiments to visualize and measure flow fields in the Novacor left ventricular assist system (LVAS). The experiments utilize a multiple exposure, optical imaging technique called fluorescent image tracking velocimetry (FITV) to hack the motion of small, neutrally-buoyant particles in a flowing fluid.
Center for computation and visualization of geometric structures. Final report, 1992 - 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-11-01
This report describes the overall goals and the accomplishments of the Geometry Center of the University of Minnesota, whose mission is to develop, support, and promote computational tools for visualizing geometric structures, for facilitating communication among mathematical and computer scientists and between these scientists and the public at large, and for stimulating research in geometry.
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Liu, I-Hsiung
1985-01-01
This Working Paper Series entry represents a collection of presentation visuals associated with the companion report entitled Natural Language Query System Design for Interactive Information Storage and Retrieval Systems, USL/DBMS NASA/RECON Working Paper Series report number DBMS.NASA/RECON-17.
Visual Scanning: Comparisons Between Student and Instructor Pilots. Final Report.
ERIC Educational Resources Information Center
DeMaio, Joseph; And Others
The performance of instructor pilots and student pilots was compared in two visual scanning tasks. In the first task both groups were shown slides of T-37 instrument displays in which errors were to be detected. Instructor pilots detected errors faster and with greater accuracy than student pilots, thus providing evidence for the validity of the…
A Visualization System for Predicting Learning Activities Using State Transition Graphs
ERIC Educational Resources Information Center
Okubo, Fumiya; Shimada, Atsushi; Taniguchi, Yuta
2017-01-01
In this paper, we present a system for visualizing learning logs of a course in progress together with predictions of learning activities of the following week and the final grades of students by state transition graphs. Data are collected from 236 students attending the course in progress and from 209 students attending the past course for…
ERIC Educational Resources Information Center
McGrady, Harold J.; Olson, Don A.
To describe and compare the psychosensory functioning of normal children and children with specific learning disabilities, 62 learning disabled and 68 normal children were studied. Each child was given a battery of thirteen subtests on an automated psychosensory system representing various combinations of auditory and visual intra- and…
The generation of criteria for selecting analytical tools for landscape management
Marilyn Duffey-Armstrong
1979-01-01
This paper presents an approach to generating criteria for selecting the analytical tools used to assess visual resources for various landscape management tasks. The approach begins by first establishing the overall parameters for the visual assessment task, and follows by defining the primary requirements of the various sets of analytical tools to be used. Finally,...
A Review of Visual Representations of Physiologic Data
2016-01-01
Background Physiological data is derived from electrodes attached directly to patients. Modern patient monitors are capable of sampling data at frequencies in the range of several million bits every hour. Hence the potential for cognitive threat arising from information overload and diminished situational awareness becomes increasingly relevant. A systematic review was conducted to identify novel visual representations of physiologic data that address cognitive, analytic, and monitoring requirements in critical care environments. Objective The aims of this review were to identify knowledge pertaining to (1) support for conveying event information via tri-event parameters; (2) identification of the use of visual variables across all physiologic representations; (3) aspects of effective design principles and methodology; (4) frequency of expert consultations; (5) support for user engagement and identifying heuristics for future developments. Methods A review was completed of papers published as of August 2016. Titles were first collected and analyzed using an inclusion criteria. Abstracts resulting from the first pass were then analyzed to produce a final set of full papers. Each full paper was passed through a data extraction form eliciting data for comparative analysis. Results In total, 39 full papers met all criteria and were selected for full review. Results revealed great diversity in visual representations of physiological data. Visual representations spanned 4 groups including tabular, graph-based, object-based, and metaphoric displays. The metaphoric display was the most popular (n=19), followed by waveform displays typical to the single-sensor-single-indicator paradigm (n=18), and finally object displays (n=9) that utilized spatiotemporal elements to highlight changes in physiologic status. Results obtained from experiments and evaluations suggest specifics related to the optimal use of visual variables, such as color, shape, size, and texture have not been fully understood. Relationships between outcomes and the users’ involvement in the design process also require further investigation. A very limited subset of visual representations (n=3) support interactive functionality for basic analysis, while only one display allows the user to perform analysis including more than one patient. Conclusions Results from the review suggest positive outcomes when visual representations extend beyond the typical waveform displays; however, there remain numerous challenges. In particular, the challenge of extensibility limits their applicability to certain subsets or locations, challenge of interoperability limits its expressiveness beyond physiologic data, and finally the challenge of instantaneity limits the extent of interactive user engagement. PMID:27872033
Kohnen, Thomas; Herzog, Michael; Hemkeppler, Eva; Schönbrunn, Sabrina; De Lorenzo, Nina; Petermann, Kerstin; Böhm, Myriam
2017-12-01
To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.
Monocular oral reading after treatment of dense congenital unilateral cataract
Birch, Eileen E.; Cheng, Christina; Christina, V; Stager, David R.
2010-01-01
Background Good long-term visual acuity outcomes for children with dense congenital unilateral cataracts have been reported following early surgery and good compliance with postoperative amblyopia therapy. However, treated eyes rarely achieve normal visual acuity and there has been no formal evaluation of the utility of the treated eye for reading. Methods Eighteen children previously treated for dense congenital unilateral cataract were tested monocularly with the Gray Oral Reading Test, 4th edition (GORT-4) at 7 to 13 years of age using two passages for each eye, one at grade level and one at +1 above grade level. In addition, right eyes of 55 normal children age 7 to 13 served as a control group. The GORT-4 assesses reading rate, accuracy, fluency, and comprehension. Results Visual acuity of treated eyes ranged from 0.1 to 2.0 logMAR and of fellow eyes from −0.1 to 0.2 logMAR. Treated eyes scored significantly lower than fellow and normal control eyes on all scales at grade level and at +1 above grade level. Monocular reading rate, accuracy, fluency, and comprehension were correlated with visual acuity of treated eyes (rs = −0.575 to −0.875, p < 0.005). Treated eyes with 0.1-0.3 logMAR visual acuity did not differ from fellow or normal control eyes in rate, accuracy, fluency, or comprehension when reading at grade level or at +1 above grade level. Fellow eyes did not differ from normal controls on any reading scale. Conclusions Excellent visual acuity outcomes following treatment of dense congenital unilateral cataracts are associated with normal reading ability of the treated eye in school-age children. PMID:20603057
A Builder's Guide to Super Good Cents Contruction and Sales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
OSU Extension Energy Program; United States. Bonneville Power Administration.
This Builder's guide describes the Super Good Cents {reg sign} program and the benefits available to participating builders. It explains the program standards and the typical building techniques used by Super Good Cents builders. Finally, the guide tells how you can participate and answers many of the questions asked by builders about the Super Good Cents program.
An overview of 3D software visualization.
Teyseyre, Alfredo R; Campo, Marcelo R
2009-01-01
Software visualization studies techniques and methods for graphically representing different aspects of software. Its main goal is to enhance, simplify and clarify the mental representation a software engineer has of a computer system. During many years, visualization in 2D space has been actively studied, but in the last decade, researchers have begun to explore new 3D representations for visualizing software. In this article, we present an overview of current research in the area, describing several major aspects like: visual representations, interaction issues, evaluation methods and development tools. We also perform a survey of some representative tools to support different tasks, i.e., software maintenance and comprehension, requirements validation and algorithm animation for educational purposes, among others. Finally, we conclude identifying future research directions.
Pillai, Roshni; Yathiraj, Asha
2017-09-01
The study evaluated whether there exists a difference/relation in the way four different memory skills (memory score, sequencing score, memory span, & sequencing span) are processed through the auditory modality, visual modality and combined modalities. Four memory skills were evaluated on 30 typically developing children aged 7 years and 8 years across three modality conditions (auditory, visual, & auditory-visual). Analogous auditory and visual stimuli were presented to evaluate the three modality conditions across the two age groups. The children obtained significantly higher memory scores through the auditory modality compared to the visual modality. Likewise, their memory scores were significantly higher through the auditory-visual modality condition than through the visual modality. However, no effect of modality was observed on the sequencing scores as well as for the memory and the sequencing span. A good agreement was seen between the different modality conditions that were studied (auditory, visual, & auditory-visual) for the different memory skills measures (memory scores, sequencing scores, memory span, & sequencing span). A relatively lower agreement was noted only between the auditory and visual modalities as well as between the visual and auditory-visual modality conditions for the memory scores, measured using Bland-Altman plots. The study highlights the efficacy of using analogous stimuli to assess the auditory, visual as well as combined modalities. The study supports the view that the performance of children on different memory skills was better through the auditory modality compared to the visual modality. Copyright © 2017 Elsevier B.V. All rights reserved.
Ethambutol/Linezolid Toxic Optic Neuropathy.
Libershteyn, Yevgeniya
2016-02-01
To report a rare toxic optic neuropathy after long-term use of two medications: ethambutol and linezolid. A 65-year-old man presented to the Miami Veterans Affairs Medical Center in December 2014 for evaluation of progressive vision decrease in both eyes. The patient presented with best-corrected visual acuities of 20/400 in the right eye and counting fingers at 5 feet in the left eye. Color vision was significantly reduced in both eyes. Visual fields revealed a cecocentral defect in both eyes. His fundus and optic nerve examination was unremarkable. Because vision continued to decline after discontinuation of ethambutol, linezolid was also discontinued, after which vision, color vision, and visual fields improved. Because of these findings, the final diagnosis was toxic optic neuropathy. Final visual outcome was 20/30 in the right eye and 20/40 in the left eye. Drug-associated toxic optic neuropathy is a rare but vision-threatening condition. Diagnosis is made based on an extensive case history and careful clinical examination. The examination findings include varying decrease in vision, normal pupils and extraocular muscles, and unremarkable fundoscopy, with the possibility of swollen optic discs in the acute stage of the optic neuropathy. Other important findings descriptive of toxic optic neuropathy include decreased color vision and cecocentral visual field defects. This case illustrates the importance of knowledge of all medications and/or substances a patient consumes that may cause a toxic reaction and discontinuing them immediately if the visual functions are worsening or not improving.
Sittivarakul, Wantanee; Aui-aree, Nipat
2009-03-01
To study the demographics, clinical features, treatment, and visual outcomes of progressive outer retinal necrosis (PORN) in a group of Thai patients. All cases of AIDS with a clinical diagnosis of PORN in a major tertiary referral hospital in southern Thailand between January 2003 and June 2007 were retrospectively reviewed. Demographic data, clinical features, treatment regimens, and visual outcomes were analyzed. Seven patients (11 eyes) were studied. The mean age was 44.7 years. The median CD4 count was 12 cells/mm3. A known history of cutaneous zoster was documented in 57% of cases. The median follow-up period was 17 weeks. Fifty-seven percent of the patients had bilateral disease. A majority of eyes (45.4%) had initial visual acuity of less than 20/50 to equal to or better than 20/200. About two-thirds of the eyes had anterior chamber cells. Vitritis and retinal lesions scattered throughout both posterior pole and peripheral retina were found in 72.7%. Either intravenous acyclovir in combination with intravitreal ganciclovir injections or intravenous aclyclovir alone was used for initial treatment. Retinal detachment occurred in 54.5%. Final visual acuity worsened (loss of 3 lines on the ETDRS chart or more) in 60%. Visual acuity was no light perception in 45.5% at the final recorded follow-up. Demographics, clinical features and treatment outcomes of PORN in this group of Thai patients were comparable with studies from other countries. Visual prognosis is still poor with current treatment regimens.
Visual information mining in remote sensing image archives
NASA Astrophysics Data System (ADS)
Pelizzari, Andrea; Descargues, Vincent; Datcu, Mihai P.
2002-01-01
The present article focuses on the development of interactive exploratory tools for visually mining the image content in large remote sensing archives. Two aspects are treated: the iconic visualization of the global information in the archive and the progressive visualization of the image details. The proposed methods are integrated in the Image Information Mining (I2M) system. The images and image structure in the I2M system are indexed based on a probabilistic approach. The resulting links are managed by a relational data base. Both the intrinsic complexity of the observed images and the diversity of user requests result in a great number of associations in the data base. Thus new tools have been designed to visualize, in iconic representation the relationships created during a query or information mining operation: the visualization of the query results positioned on the geographical map, quick-looks gallery, visualization of the measure of goodness of the query, visualization of the image space for statistical evaluation purposes. Additionally the I2M system is enhanced with progressive detail visualization in order to allow better access for operator inspection. I2M is a three-tier Java architecture and is optimized for the Internet.
Chua, Paul Y; Mustafa, Mohammed S; Scott, Neil W; Kumarasamy, Manjula; Azuara-Blanco, Augusto
2013-01-01
To evaluate the influence of socioeconomic factors on visual acuity before cataract surgery. The medical case notes of 240 consecutive patients listed for cataract surgery from January 1, 2010, at Grampian University Hospital, Aberdeen, were reviewed retrospectively. Patients with ocular comorbidity were excluded. Demographics, postal codes, and visual acuity were recorded. Scottish Index of Multiple Deprivation was used to determine the deprivation rank. Home location was classified as urban or rural. The effect of these parameters on preoperative visual acuity was investigated using chi-square tests or Fisher exact test as appropriate. A total of 184 patients (mean 75 years) were included. A total of 127 (69%) patients had visual acuity of 6/12 or better. An association was found between affluence and preoperative visual acuity of 6/12 or better (χ2trend = 4.97, p = 0.03), with a significant rising trend across quintile of deprivation. There was no evidence to suggest association between geographical region and preoperative visual acuity (p = 0.63). Affluence was associated with good visual acuity (6/12 or better) before cataract surgery. There was no difference in preoperative visual acuity between rural and urban populations.
Pomplun, M; Reingold, E M; Shen, J
2001-09-01
In three experiments, participants' visual span was measured in a comparative visual search task in which they had to detect a local match or mismatch between two displays presented side by side. Experiment 1 manipulated the difficulty of the comparative visual search task by contrasting a mismatch detection task with a substantially more difficult match detection task. In Experiment 2, participants were tested in a single-task condition involving only the visual task and a dual-task condition in which they concurrently performed an auditory task. Finally, in Experiment 3, participants performed two dual-task conditions, which differed in the difficulty of the concurrent auditory task. Both the comparative search task difficulty (Experiment 1) and the divided attention manipulation (Experiments 2 and 3) produced strong effects on visual span size.
The practice of agent-based model visualization.
Dorin, Alan; Geard, Nicholas
2014-01-01
We discuss approaches to agent-based model visualization. Agent-based modeling has its own requirements for visualization, some shared with other forms of simulation software, and some unique to this approach. In particular, agent-based models are typified by complexity, dynamism, nonequilibrium and transient behavior, heterogeneity, and a researcher's interest in both individual- and aggregate-level behavior. These are all traits requiring careful consideration in the design, experimentation, and communication of results. In the case of all but final communication for dissemination, researchers may not make their visualizations public. Hence, the knowledge of how to visualize during these earlier stages is unavailable to the research community in a readily accessible form. Here we explore means by which all phases of agent-based modeling can benefit from visualization, and we provide examples from the available literature and online sources to illustrate key stages and techniques.
Audio-visual temporal perception in children with restored hearing.
Gori, Monica; Chilosi, Anna; Forli, Francesca; Burr, David
2017-05-01
It is not clear how audio-visual temporal perception develops in children with restored hearing. In this study we measured temporal discrimination thresholds with an audio-visual temporal bisection task in 9 deaf children with restored audition, and 22 typically hearing children. In typically hearing children, audition was more precise than vision, with no gain in multisensory conditions (as previously reported in Gori et al. (2012b)). However, deaf children with restored audition showed similar thresholds for audio and visual thresholds and some evidence of gain in audio-visual temporal multisensory conditions. Interestingly, we found a strong correlation between auditory weighting of multisensory signals and quality of language: patients who gave more weight to audition had better language skills. Similarly, auditory thresholds for the temporal bisection task were also a good predictor of language skills. This result supports the idea that the temporal auditory processing is associated with language development. Copyright © 2017. Published by Elsevier Ltd.
Learning invariance from natural images inspired by observations in the primary visual cortex.
Teichmann, Michael; Wiltschut, Jan; Hamker, Fred
2012-05-01
The human visual system has the remarkable ability to largely recognize objects invariant of their position, rotation, and scale. A good interpretation of neurobiological findings involves a computational model that simulates signal processing of the visual cortex. In part, this is likely achieved step by step from early to late areas of visual perception. While several algorithms have been proposed for learning feature detectors, only few studies at hand cover the issue of biologically plausible learning of such invariance. In this study, a set of Hebbian learning rules based on calcium dynamics and homeostatic regulations of single neurons is proposed. Their performance is verified within a simple model of the primary visual cortex to learn so-called complex cells, based on a sequence of static images. As a result, the learned complex-cell responses are largely invariant to phase and position.
Ergonomics and accessibility for people with visual impairment in hotels.
Dos Santos, Larissa Nascimento; de Carvalho, Ricardo José Matos
2012-01-01
This article presents a diagnosis of luxury or superior hotels in the city of Natal, located in the state of Rio Grande do Norte, in northeastern Brazil, in what concerns accessibility to the visually impaired. The main objective is to present the guiding principles to design actions and interventions that must be considered in the preparation or revision of technical standards and manuals of good practice in accessibility related to people with visual impairments who are hotel users. The survey showed that the hotels do not meet the normative indications of accessibility, their facilities are in-accessible (have prevented access) or of reduced accessibility and its employees are not prepared to provide adequate hospital services for people with visual impairment. It was concluded that some of the accessibility problems faced by people with visual impairments are also faced by people in general.
Automatic classification of visual evoked potentials based on wavelet decomposition
NASA Astrophysics Data System (ADS)
Stasiakiewicz, Paweł; Dobrowolski, Andrzej P.; Tomczykiewicz, Kazimierz
2017-04-01
Diagnosis of part of the visual system, that is responsible for conducting compound action potential, is generally based on visual evoked potentials generated as a result of stimulation of the eye by external light source. The condition of patient's visual path is assessed by set of parameters that describe the time domain characteristic extremes called waves. The decision process is compound therefore diagnosis significantly depends on experience of a doctor. The authors developed a procedure - based on wavelet decomposition and linear discriminant analysis - that ensures automatic classification of visual evoked potentials. The algorithm enables to assign individual case to normal or pathological class. The proposed classifier has a 96,4% sensitivity at 10,4% probability of false alarm in a group of 220 cases and area under curve ROC equals to 0,96 which, from the medical point of view, is a very good result.
The climate visualizer: Sense-making through scientific visualization
NASA Astrophysics Data System (ADS)
Gordin, Douglas N.; Polman, Joseph L.; Pea, Roy D.
1994-12-01
This paper describes the design of a learning environment, called the Climate Visualizer, intended to facilitate scientific sense-making in high school classrooms by providing students the ability to craft, inspect, and annotate scientific visualizations. The theoretical back-ground for our design presents a view of learning as acquiring and critiquing cultural practices and stresses the need for students to appropriate the social and material aspects of practice when learning an area. This is followed by a description of the design of the Climate Visualizer, including detailed accounts of its provision of spatial and temporal context and the quantitative and visual representations it employs. A broader context is then explored by describing its integration into the high school science classroom. This discussion explores how visualizations can promote the creation of scientific theories, especially in conjunction with the Collaboratory Notebook, an embedded environment for creating and critiquing scientific theories and visualizations. Finally, we discuss the design trade-offs we have made in light of our theoretical orientation, and our hopes for further progress.
Prevalence of oral health status in visually impaired children.
Reddy, Kvkk; Sharma, A
2011-01-01
The epidemiological investigation was carried out among 228 children selected from two schools of similar socioeconomic strata in and around Chennai city. The study population consisted of 128 visually impaired and 100 normal school going children in the age group of 6-15 years. The examination procedure and criteria were those recommended by W.H.O. in 1997. The mean DMFT/deft was 1.1 and 0.17,0.87 and 0.47 in visually impaired and normal children, respectively. Oral hygiene levels in both groups were: mean value in good category was 0.19 and 0.67, in fair category was 0.22 and 0.1, and in poor category 0.40 and 0.23 in visually impaired children and normal children, respectively. Trauma experienced children were 0.29 and 0.13 in visually impaired children and normal children, respectively. The conclusions drawn from this study were that there was a greater prevalence of dental caries, poorer oral hygiene, and higher incidence of trauma in visually impaired children.
Contrasting vertical and horizontal representations of affect in emotional visual search.
Damjanovic, Ljubica; Santiago, Julio
2016-02-01
Independent lines of evidence suggest that the representation of emotional evaluation recruits both vertical and horizontal spatial mappings. These two spatial mappings differ in their experiential origins and their productivity, and available data suggest that they differ in their saliency. Yet, no study has so far compared their relative strength in an attentional orienting reaction time task that affords the simultaneous manifestation of both types of mapping. Here, we investigated this question using a visual search task with emotional faces. We presented angry and happy face targets and neutral distracter faces in top, bottom, left, and right locations on the computer screen. Conceptual congruency effects were observed along the vertical dimension supporting the 'up = good' metaphor, but not along the horizontal dimension. This asymmetrical processing pattern was observed when faces were presented in a cropped (Experiment 1) and whole (Experiment 2) format. These findings suggest that the 'up = good' metaphor is more salient and readily activated than the 'right = good' metaphor, and that the former outcompetes the latter when the task context affords the simultaneous activation of both mappings.
Vajpayee, R B; Angra, S K; Honavar, S G
1994-04-15
Over a period of two years we performed combined penetrating keratoplasty, cataract extraction, and intraocular lens implantation in seven children between the ages of 2 and 12 years old. The interval between trauma and the surgery varied from six weeks to six months (3.5 +/- 1.6 months, mean +/- SD). All of the patients had undergone primary repair of corneal perforation. Fresh corneas preserved in McCarey-Kaufman medium were used. The graft size was 7.5 mm with 0.5 mm disparity. Posterior chamber polymethylmethacrylate C-loop lenses were used in all cases. The surgeon's average postkeratoplasty keratometry was used in the calculation of intraocular lens power. The follow-up period ranged from nine to 36 months (18 +/- 9.1 months, mean +/- SD). Six grafts remained clear at the final follow-up. The visual acuity ranged from 20/40 to 20/200 with final astigmatism ranging from 0.5 diopter to 2.0 diopters. One patient developed a retinal detachment 12 months after surgery, which was successfully reattached. One patient, who had preoperative corneal vascularization, had graft rejection, which was treated medically. Our limited series suggests that the triple ocular procedure is a good choice for the treatment of corneolenticular trauma in children. The proper postoperative treatment includes vigorous antiamblyopia therapy and Nd:YAG laser treatment of after-cataracts.
2010-05-21
ISS023-E-047827 (21 May 2010) --- NASA astronaut Michael Good, STS-132 mission specialist, participates in the mission?s third and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the six-hour, 46-minute spacewalk, Good and NASA astronaut Garrett Reisman (out of frame), mission specialist, completed the installation of the final two of the six new batteries for the B side of the port 6 solar array. In addition, the astronauts installed a backup ammonia jumper cable between the port 4 and 5 trusses of the station, transferred a Power and Data Grapple Fixture from the shuttle to the station, and reconfigured some tools.
2010-05-21
ISS023-E-047864 (21 May 2010) --- NASA astronaut Michael Good, STS-132 mission specialist, participates in the mission?s third and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the six-hour, 46-minute spacewalk, Good and NASA astronaut Garrett Reisman (out of frame), mission specialist, completed the installation of the final two of the six new batteries for the B side of the port 6 solar array. In addition, the astronauts installed a backup ammonia jumper cable between the port 4 and 5 trusses of the station, transferred a Power and Data Grapple Fixture from the shuttle to the station, and reconfigured some tools.
2010-05-21
ISS023-E-047845 (21 May 2010) --- NASA astronaut Michael Good, STS-132 mission specialist, participates in the mission?s third and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the six-hour, 46-minute spacewalk, Good and NASA astronaut Garrett Reisman (out of frame), mission specialist, completed the installation of the final two of the six new batteries for the B side of the port 6 solar array. In addition, the astronauts installed a backup ammonia jumper cable between the port 4 and 5 trusses of the station, transferred a Power and Data Grapple Fixture from the shuttle to the station, and reconfigured some tools.
2010-05-21
ISS023-E-047833 (21 May 2010) --- NASA astronaut Michael Good, STS-132 mission specialist, participates in the mission?s third and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the six-hour, 46-minute spacewalk, Good and NASA astronaut Garrett Reisman (out of frame), mission specialist, completed the installation of the final two of the six new batteries for the B side of the port 6 solar array. In addition, the astronauts installed a backup ammonia jumper cable between the port 4 and 5 trusses of the station, transferred a Power and Data Grapple Fixture from the shuttle to the station, and reconfigured some tools.
2010-05-21
ISS023-E-049791 (21 May 2010) --- NASA astronauts Garrett Reisman (bottom) and Michael Good, both STS-132 mission specialists, participate in the mission?s third and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the six-hour, 46-minute spacewalk, Reisman and Good completed the installation of the final two of the six new batteries for the B side of the port 6 solar array. In addition, the astronauts installed a backup ammonia jumper cable between the port 4 and 5 trusses of the station, transferred a Power and Data Grapple Fixture from the shuttle to the station, and reconfigured some tools.
2010-05-21
ISS023-E-047828 (21 May 2010) --- NASA astronaut Michael Good, STS-132 mission specialist, participates in the mission?s third and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the six-hour, 46-minute spacewalk, Good and NASA astronaut Garrett Reisman (out of frame), mission specialist, completed the installation of the final two of the six new batteries for the B side of the port 6 solar array. In addition, the astronauts installed a backup ammonia jumper cable between the port 4 and 5 trusses of the station, transferred a Power and Data Grapple Fixture from the shuttle to the station, and reconfigured some tools.
Udagawa, Sachiko; Iwase, Aiko; Susuki, Yuto; Kunimatsu-Sanuki, Shiho; Fukuchi, Takeo; Matsumoto, Chota; Ohno, Yuko; Ono, Hiroshi; Sugiyama, Kazuhisa; Araie, Makoto
2018-01-01
Purpose Traffic accidents are associated with the visual function of drivers, as well as many other factors. Driving simulator systems have the advantage of controlling for traffic- and automobile-related conditions, and using pinhole glasses can control the degree of concentric concentration of the visual field. We evaluated the effect of concentric constriction of the visual field on automobile driving, using driving simulator tests. Methods Subjects meeting criteria for normal eyesight were included in the study. Pinhole glasses with variable aperture sizes were adjusted to mimic the conditions of concentric visual field constrictions of 10° and 15°, using a CLOCK CHART®. The test contained 8 scenarios (2 oncoming right-turning cars and 6 jump-out events from the side). Results Eighty-eight subjects were included in the study; 37 (mean age = 52.9±15.8 years) subjects were assigned to the 15° group, and 51 (mean = 48.6±15.5 years) were assigned to the 10° group. For all 8 scenarios, the number of accidents was significantly higher among pinhole wearing subjects. The average number of all types of accidents per person was significantly higher in the pinhole 10° group (4.59±1.81) than the pinhole 15° group (3.68±1.49) (P = 0.032). The number of accidents associated with jump-out scenarios, in which a vehicle approaches from the side on a straight road with a good view, was significantly higher in the pinhole 10° group than in the pinhole 15° group. Conclusions Concentric constriction of the visual field was associated with increased number of traffic accidents. The simulation findings indicated that a visual field of 10° to 15° may be important for avoiding collisions in places where there is a straight road with a good view. PMID:29538425
Song, Jae-Jin; Lee, Hyo-Jeong; Kang, Hyejin; Lee, Dong Soo; Chang, Sun O; Oh, Seung Ha
2015-03-01
While deafness-induced plasticity has been investigated in the visual and auditory domains, not much is known about language processing in audiovisual multimodal environments for patients with restored hearing via cochlear implant (CI) devices. Here, we examined the effect of agreeing or conflicting visual inputs on auditory processing in deaf patients equipped with degraded artificial hearing. Ten post-lingually deafened CI users with good performance, along with matched control subjects, underwent H 2 (15) O-positron emission tomography scans while carrying out a behavioral task requiring the extraction of speech information from unimodal auditory stimuli, bimodal audiovisual congruent stimuli, and incongruent stimuli. Regardless of congruency, the control subjects demonstrated activation of the auditory and visual sensory cortices, as well as the superior temporal sulcus, the classical multisensory integration area, indicating a bottom-up multisensory processing strategy. Compared to CI users, the control subjects exhibited activation of the right ventral premotor-supramarginal pathway. In contrast, CI users activated primarily the visual cortices more in the congruent audiovisual condition than in the null condition. In addition, compared to controls, CI users displayed an activation focus in the right amygdala for congruent audiovisual stimuli. The most notable difference between the two groups was an activation focus in the left inferior frontal gyrus in CI users confronted with incongruent audiovisual stimuli, suggesting top-down cognitive modulation for audiovisual conflict. Correlation analysis revealed that good speech performance was positively correlated with right amygdala activity for the congruent condition, but negatively correlated with bilateral visual cortices regardless of congruency. Taken together these results suggest that for multimodal inputs, cochlear implant users are more vision-reliant when processing congruent stimuli and are disturbed more by visual distractors when confronted with incongruent audiovisual stimuli. To cope with this multimodal conflict, CI users activate the left inferior frontal gyrus to adopt a top-down cognitive modulation pathway, whereas normal hearing individuals primarily adopt a bottom-up strategy.
Visual acuity and legal visual requirement to drive a passenger vehicle.
Kiel, A W; Butler, T; Alwitry, A
2003-07-01
(1). To test the consistency and ease with which number-plates of different component figures can be read under DVLA driving test conditions; (2). to test the relative difficulty of reading corresponding figures on registration plates of white and yellow backgrounds.Design Prospective study of consecutive eligible clinic patients. Ophthalmology outpatients. 210 individuals with a corrected visual acuity with both eyes open of between 6/9 and 6/12. The ability to read three different number-plates under standard DVLA driving-test conditions (ie at 20.5 m in good daylight with glasses if worn) and the ability to read identical number-plates against a white and a yellow background. There is a significant difference between the ease with which three different number-plates can be read depending on their letter and numeral composition, although this did not seem to be significantly affected by whether they were printed on a yellow or white background. Only 92.3% of subjects could read all the number-plates at the legal distance, 96.7% could read at least one number-plate at the legal distance and 3.3% of the test subjects could not read any of the number-plates at 20.5 m. The current test protocol used to obtain a driving licence and, moreover, the test the police will employ to assess visual competence to drive, is highly variable and is unlikely to give consistent repeatable results. The performance of those with equally good visual acuity is unpredictable and is highly dependent on the number-plate they are asked to read. This variability could exclude some who would otherwise pass the test or pass an individual with a visual acuity below accepted standards. The forthcoming changes in the regulations for design of number-plates is an ideal opportunity to standardise the whole testing procedure for driving visual acuity.
[Effectiveness and safety of oxcarbazepine in chronic neuropathic pain: a study of 40 cases].
Fenollosa-Vázquez, P; Canós-Verdecho, M A; Núñez-Cornejo, C; Pallarés-Delgado, J
Neuropathic pain (NP) often fails to respond to the commonly established analgesic treatment. This fact, together with the existence of side effects, has led to the need to evaluate the analgesic effectiveness of antiepileptic drugs, which, as in the case of oxcarbazepine (OXC), are a valid alternative. The aim of this study was to evaluate the effectiveness and safety of OXC in patients suffering from chronic NP. We conducted a prospective, open study involving a series of 40 patients diagnosed with a long history of NP, which was previously resistant to different kinds of treatment with anticonvulsants, non-steroidal anti-inflammatory (NSAI) drugs, opiates and adjuncts. Patients were treated with OXC and they were evaluated in both the basal (prior to treatment) and final visits (after treatment) by means of the visual analogue scale (VAS), SF-McGill questionnaire and the Lattinen test. The patient's general impression of the result was also obtained. The statistical analysis was performed by calculating the "effect size", by computing Cohen's d. Treatment with OXC diminishes different symptomatic variations of this pain, but especially so in the case of lancinating discharges (d = 0.87, important effect) and burning pain (d = 0.60, moderate-important effect), although the allodynia (d = 0.48, moderate effect) also improved with treatment. In the opinion of the patients themselves, response to treatment was good or very good in 50% of cases. The chief side effects observed were dizziness, drowsiness and abdominal upsets. OXC can be seen as a therapeutic alternative to be taken very much into account in patients with NP having different aetiologies; it has a good benefit-risk ratio and is a form of treatment that is well accepted by patients.
A Builder`s Guide to Super Good Cents Contruction and Sales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
OSU Extension Energy Program; United States. Bonneville Power Administration.
This Builder`s guide describes the Super Good Cents {reg_sign} program and the benefits available to participating builders. It explains the program standards and the typical building techniques used by Super Good Cents builders. Finally, the guide tells how you can participate and answers many of the questions asked by builders about the Super Good Cents program.
The Effects of the Strength and Number of Visual Mediators in the Learning Process. Final Report.
ERIC Educational Resources Information Center
Bolz, Charles R.; Ackerman, Jerrold
The role of visual imagery in the learning of letter-sound combinations was investigated using such mediating images as two scoops of ice cream for the letter "m." In a preliminary study, high-, medium-, and low-strength mediating images were determined for each letter-sound combination. The 216 kindergarten subjects in the main study were…
ERIC Educational Resources Information Center
Martin, Elizabeth L.; Cataneo, Daniel F.
A study was conducted by the Air Force to determine the extent to which takeoff/landing skills learned in a simulator equipped with a night visual system would transfer to daytime performance in the aircraft. A transfer-of-training design was used to assess the differential effectiveness of simulator training with a day versus a night…
HEALTH EFFECTS OF CHRONIC EXPOSURE TO ARSENIC IN DRINKING WATER IN INNER MONGOLIA: II. VIBROTACTILE AND VISUAL MEASURES.
David Otto, Ph.D., Judy Mumford, Ph.D., Richard Kwok, M.S.P.H., Ken Hudnell, Ph.D.,
U.S. Environmental Protection Agency; Yanhong Li, M.D., Yajuan ...
Experience improves feature extraction in Drosophila.
Peng, Yueqing; Xi, Wang; Zhang, Wei; Zhang, Ke; Guo, Aike
2007-05-09
Previous exposure to a pattern in the visual scene can enhance subsequent recognition of that pattern in many species from honeybees to humans. However, whether previous experience with a visual feature of an object, such as color or shape, can also facilitate later recognition of that particular feature from multiple visual features is largely unknown. Visual feature extraction is the ability to select the key component from multiple visual features. Using a visual flight simulator, we designed a novel protocol for visual feature extraction to investigate the effects of previous experience on visual reinforcement learning in Drosophila. We found that, after conditioning with a visual feature of objects among combinatorial shape-color features, wild-type flies exhibited poor ability to extract the correct visual feature. However, the ability for visual feature extraction was greatly enhanced in flies trained previously with that visual feature alone. Moreover, we demonstrated that flies might possess the ability to extract the abstract category of "shape" but not a particular shape. Finally, this experience-dependent feature extraction is absent in flies with defective MBs, one of the central brain structures in Drosophila. Our results indicate that previous experience can enhance visual feature extraction in Drosophila and that MBs are required for this experience-dependent visual cognition.
Efficacy of a perceptual and visual-motor skill intervention program for students with dyslexia.
Fusco, Natália; Germano, Giseli Donadon; Capellini, Simone Aparecida
2015-01-01
To verify the efficacy of a perceptual and visual-motor skill intervention program for students with dyslexia. The participants were 20 students from third to fifth grade of a public elementary school in Marília, São Paulo, aged from 8 years to 11 years and 11 months, distributed into the following groups: Group I (GI; 10 students with developmental dyslexia) and Group II (GII; 10 students with good academic performance). A perceptual and visual-motor intervention program was applied, which comprised exercises for visual-motor coordination, visual discrimination, visual memory, visual-spatial relationship, shape constancy, sequential memory, visual figure-ground coordination, and visual closure. In pre- and post-testing situations, both groups were submitted to the Test of Visual-Perceptual Skills (TVPS-3), and the quality of handwriting was analyzed using the Dysgraphia Scale. The analyzed statistical results showed that both groups of students had dysgraphia in pretesting situation. In visual perceptual skills, GI presented a lower performance compared to GII, as well as in the quality of writing. After undergoing the intervention program, GI increased the average of correct answers in TVPS-3 and improved the quality of handwriting. The developed intervention program proved appropriate for being applied to students with dyslexia, and showed positive effects because it provided improved visual perception skills and quality of writing for students with developmental dyslexia.
Attractive Flicker--Guiding Attention in Dynamic Narrative Visualizations.
Waldner, Manuela; Le Muzic, Mathieu; Bernhard, Matthias; Purgathofer, Werner; Viola, Ivan
2014-12-01
Focus+context techniques provide visual guidance in visualizations by giving strong visual prominence to elements of interest while the context is suppressed. However, finding a visual feature to enhance for the focus to pop out from its context in a large dynamic scene, while leading to minimal visual deformation and subjective disturbance, is challenging. This paper proposes Attractive Flicker, a novel technique for visual guidance in dynamic narrative visualizations. We first show that flicker is a strong visual attractor in the entire visual field, without distorting, suppressing, or adding any scene elements. The novel aspect of our Attractive Flicker technique is that it consists of two signal stages: The first "orientation stage" is a short but intensive flicker stimulus to attract the attention to elements of interest. Subsequently, the intensive flicker is reduced to a minimally disturbing luminance oscillation ("engagement stage") as visual support to keep track of the focus elements. To find a good trade-off between attraction effectiveness and subjective annoyance caused by flicker, we conducted two perceptual studies to find suitable signal parameters. We showcase Attractive Flicker with the parameters obtained from the perceptual statistics in a study of molecular interactions. With Attractive Flicker, users were able to easily follow the narrative of the visualization on a large display, while the flickering of focus elements was not disturbing when observing the context.
Infectious keratitis after photorefractive keratectomy in the United States army and navy.
Wroblewski, Keith J; Pasternak, Joseph F; Bower, Kraig S; Schallhorn, Steven C; Hubickey, Walter J; Harrison, Cary E; Torres, Mark F; Barnes, Scott D
2006-04-01
To review the incidence, culture results, clinical course, management, and visual outcomes of infectious keratitis after photorefractive keratectomy (PRK) at 6 Army and Navy refractive surgery centers. Retrospective study. Twelve thousand six hundred sixty-eight Navy and Army sailors and service members. Army and Navy refractive surgery data banks were searched for cases of infectious keratitis. A retrospective chart review and query of the surgeons involved in the care of those patients thus identified provided data regarding preoperative preparation, perioperative medications, treatment, culture results, clinical course, and final visual acuity. Between January 1995 and May 2004, we performed a total of 25337 PRK procedures at the 6 institutions. Culture proven or clinically suspected infectious keratitis developed in 5 eyes of 5 patients. All patients received topical antibiotics perioperatively. All cases presented 2 to 7 days postoperatively. Cultures from 4 cases grew Staphylococcus, including 2 methicillin-resistant S. aureus (MRSA). One case of presumed infectious keratitis was culture negative. There were no reported cases of mycobacterial or fungal keratitis. In addition, we identified 26 eyes with corneal infiltrates in the first postoperative week that were felt to be sterile, and which resolved upon removal of the bandage contact lens and increasing antibiotic coverage. Infectious keratitis is a rare but potentially vision-threatening complication after PRK. It is often caused by gram-positive organisms, including MRSA. Early diagnosis, appropriate laboratory testing, and aggressive antimicrobial therapy can result in good outcomes.
Liu, Dan; Li, Xingrui; Zhou, Junkai; Liu, Shibo; Tian, Tian; Song, Yanling; Zhu, Zhi; Zhou, Leiji; Ji, Tianhai; Yang, Chaoyong
2017-10-15
Enzyme-linked immunosorbent assay (ELISA) is a popular laboratory technique for detection of disease-specific protein biomarkers with high specificity and sensitivity. However, ELISA requires labor-intensive and time-consuming procedures with skilled operators and spectroscopic instrumentation. Simplification of the procedures and miniaturization of the devices are crucial for ELISA-based point-of-care (POC) testing in resource-limited settings. Here, we present a fully integrated, instrument-free, low-cost and portable POC platform which integrates the process of ELISA and the distance readout into a single microfluidic chip. Based on manipulation using a permanent magnet, the process is initiated by moving magnetic beads with capture antibody through different aqueous phases containing ELISA reagents to form bead/antibody/antigen/antibody sandwich structure, and finally converts the molecular recognition signal into a highly sensitive distance readout for visual quantitative bioanalysis. Without additional equipment and complicated operations, our integrated ELISA-Chip with distance readout allows ultrasensitive quantitation of disease biomarkers within 2h. The ELISA-Chip method also showed high specificity, good precision and great accuracy. Furthermore, the ELISA-Chip system is highly applicable as a sandwich-based platform for the detection of a variety of protein biomarkers. With the advantages of visual analysis, easy operation, high sensitivity, and low cost, the integrated sample-in-answer-out ELISA-Chip with distance readout shows great potential for quantitative POCT in resource-limited settings. Copyright © 2017. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Wang, Wei-Wen William
This dissertation is to document experimental, local condensation and single-phase heat transfer and flow data of the minute diameter, microchannel tube and to develop correlation methods for optimizing the design of horizontal-microchannel condensers. It is essential to collect local data as the condensation progresses through several different flow patterns, since as more liquid is formed, the mechanism conducting heat transfer and flow is also changing. Therefore, the identification of the flow pattern is as important as the thermal and dynamic data. The experimental results were compared with correlation and flow regime maps from literature. The experiment using refrigerant HFC-134a in flat, multi-port aluminum tubing with 1.46mm hydraulic diameter was conducted. The characteristic of single-phase friction can be described with the analytical solution of square channel. The Gnielinski correlation provided good prediction of single-phase turbulent flow heat transfer. Higher mass fluxes and qualities resulted in increased condensation heat transfer and were more effective in the shear-dominated annular flow. The effect of temperature gradient from wall to refrigerant attributed profoundly in the gravity-dominated wavy/slug flow. Two correlation based on different flow mechanisms were developed for specified flow regimes. Finally, an asymptotic correlation was successfully proposed to account for the entire data regardless of flow patterns. Data taken from experiment and observations obtained from flow visualization, resulted in a better understanding of the physics in microchannel condensation, optimized designs in the microchannel condensers are now possible.
Thermal Conductivity and Liquid Crystal Thermometers.
ERIC Educational Resources Information Center
Edge, R. D., Ed.
1993-01-01
Describes using stock liquid crystal postcards as inexpensive classroom thermometers. Also suggests using these postcards as a good visual temperature indicator for classroom demonstrations such as temperature gradients. One such activity is provided. (MVL)
NASA Astrophysics Data System (ADS)
Ariffin, A.; Samsudin, M. A.; Zain, A. N. Md.; Hamzah, N.; Ismail, M. E.
2017-05-01
The Engineering Drawing subject develops skills in geometry drawing becoming more professional. For the concept in Engineering Drawing, students need to have good visualization skills. Visualization is needed to help students get a start before translating into a drawing. So that, Problem Based Learning (PBL) using animation mode (PBL-A) and graphics mode (PBL-G) will be implemented in class. Problem-solving process is repeatedly able to help students interpret engineering drawings step work correctly and accurately. This study examined the effects of PBL-A online and PBL-G online on visualization skills of students in polytechnics. Sixty eight mechanical engineering students have been involved in this study. The visualization test adapted from Bennett, Seashore and Wesman was used in this study. Results showed significant differences in mean scores post-test of visualization skills among the students enrolled in PBL-G with the group of students who attended PBL-A online after effects of pre-test mean score is controlled. Therefore, the effects of animation modes have a positive impact on increasing students’ visualization skills.
Coding the presence of visual objects in a recurrent neural network of visual cortex.
Zwickel, Timm; Wachtler, Thomas; Eckhorn, Reinhard
2007-01-01
Before we can recognize a visual object, our visual system has to segregate it from its background. This requires a fast mechanism for establishing the presence and location of objects independently of their identity. Recently, border-ownership neurons were recorded in monkey visual cortex which might be involved in this task [Zhou, H., Friedmann, H., von der Heydt, R., 2000. Coding of border ownership in monkey visual cortex. J. Neurosci. 20 (17), 6594-6611]. In order to explain the basic mechanisms required for fast coding of object presence, we have developed a neural network model of visual cortex consisting of three stages. Feed-forward and lateral connections support coding of Gestalt properties, including similarity, good continuation, and convexity. Neurons of the highest area respond to the presence of an object and encode its position, invariant of its form. Feedback connections to the lowest area facilitate orientation detectors activated by contours belonging to potential objects, and thus generate the experimentally observed border-ownership property. This feedback control acts fast and significantly improves the figure-ground segregation required for the consecutive task of object recognition.
The cognitive science of visual-spatial displays: implications for design.
Hegarty, Mary
2011-07-01
This paper reviews cognitive science perspectives on the design of visual-spatial displays and introduces the other papers in this topic. It begins by classifying different types of visual-spatial displays, followed by a discussion of ways in which visual-spatial displays augment cognition and an overview of the perceptual and cognitive processes involved in using displays. The paper then argues for the importance of cognitive science methods to the design of visual displays and reviews some of the main principles of display design that have emerged from these approaches to date. Cognitive scientists have had good success in characterizing the performance of well-defined tasks with relatively simple visual displays, but many challenges remain in understanding the use of complex displays for ill-defined tasks. Current research exemplified by the papers in this topic extends empirical approaches to new displays and domains, informs the development of general principles of graphic design, and addresses current challenges in display design raised by the recent explosion in availability of complex data sets and new technologies for visualizing and interacting with these data. Copyright © 2011 Cognitive Science Society, Inc.
Electropysiologic evaluation of the visual pathway in patients with multiple sclerosis.
Rodriguez-Mena, Diego; Almarcegui, Carmen; Dolz, Isabel; Herrero, Raquel; Bambo, Maria P; Fernandez, Javier; Pablo, Luis E; Garcia-Martin, Elena
2013-08-01
To evaluate the ability of visual evoked potentials and pattern electroretinograms (PERG) to detect subclinical axonal damage in patients during the early diagnostic stage of multiple sclerosis (MS). The authors also compared the ability of optical coherence tomography (OCT), PERG, and visual evoked potentials to detect axonal loss in MS patients and correlated the functional and structural properties of the retinal nerve fiber layer. Two hundred twenty-eight eyes of 114 subjects (57 MS patients and 57 age- and sex-matched healthy controls) were included. The visual pathway was evaluated based on functional and structural assessments. All patients underwent a complete ophthalmic examination that included assessment of visual acuity, ocular motility, intraocular pressure, visual field, papillary morphology, OCT, visual evoked potentials, and PERG. Visual evoked potentials (P100 latency and amplitude), PERG (N95 amplitude and N95/P50 ratio), and OCT parameters differed significantly between MS patients and healthy subjects. Moderate significant correlations were found between visual evoked potentials or PERG parameters and OCT measurements. Axonal damage in ganglion cells of the visual pathway can be detected based on structural measures provided by OCT in MS patients and by the N95 component and N95/P50 index of PERG, thus providing good correlation between function and structure.
Rea, Mark S.; Figueiro, Mariana G.
2016-01-01
Lighting technologies are rapidly evolving, creating many opportunities for good lighting within the NICU. With the widespread adoption of advanced solid-state lighting technologies, lighting no longer needs to be static. Rather, lighting systems can be more easily adjusted to the different and changing visual and non-visual needs of the professional staff, infants and family members throughout the 24-hour day. This paper provides a conceptual framework for defining good lighting in the NICU, recognizing the needs of various constituent groups, each with very different needs from the lighting. Several other papers on the topic of lighting for various constituent groups at different times of the day in the NICU are summarized. Attention is given specifically to the Recommended Standards for Newborn ICU Design, a consensus standard developed by a wide range of experts, to help the reader translate this conceptual framework to practice. PMID:28824339
Borkowska, Aneta Rita; Francuz, Piotr; Soluch, Paweł; Wolak, Tomasz
2014-10-01
The present study aimed at defining the specific traits of brain activation in teenagers with isolated spelling disorder in comparison with good spellers. fMRI examination was performed where the subject's task involved taking a decision 1/whether the visually presented words were spelled correctly or not (the orthographic decision task), and 2/whether the two presented letters strings (pseudowords) were identical or not (the visual decision task). Half of the displays showing meaningful words with an orthographic difficulty contained pairs with both words spelled correctly, and half of them contained one misspelled word. Half of the pseudowords were identical, half of them were not. The participants of the study included 15 individuals with isolated spelling disorder and 14 good spellers, aged 13-15. The results demonstrated that the essential differences in brain activation between teenagers with isolated spelling disorder and good spellers were found in the left inferior frontal gyrus, left medial frontal gyrus and right cerebellum posterior lobe, i.e. structures important for language processes, working memory and automaticity of behaviour. Spelling disorder is not only an effect of language dysfunction, it could be a symptom of difficulties in learning and automaticity of motor and visual shapes of written words, rapid information processing as well as automating use of orthographic lexicon. Copyright © 2013 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Oray, Merih; Khachatryan, Naira; Ebrahimiadib, Nazanin; Abu Samra, Khawla; Lee, Stacey; Foster, C Stephen
2016-09-01
To describe the clinical and visual outcomes of juvenile idiopathic arthritis (JIA)-associated uveitis in adults and to examine risk factors for ongoing inflammation in adulthood. Medical records were reviewed for patients with JIA-associated uveitis who were >16 years old at the final visit (the last visit prior to data collection). In total, 135 eyes of 77 patients (70 female, 7 male) were included. The mean age of patients at the final visit was 29.72 ± 11.27 years. The number of eyes with visual acuity of ≤20/50 and ≤20/200 at the final visit was 37 (28 %) and 20 (15 %), respectively; at least one ocular complication was present in 72 % of eyes. Band keratopathy was the most frequent complication (42 %), followed by cataract (25 %), posterior synechiae (22 %), maculopathy (22 %), ocular hypertension (13 %), and hypotony (5 %). At the final visit, patients who were >16 years of age at presentation to the Massachusetts Eye Research and Surgery Institution had more ocular complications and a greater degree of vision loss than patients who were ≤16 years of age. Ongoing inflammation at the final visit was noted in 40 patients (52 %). The presence of posterior synechiae, hypotony, cataract at presentation, and a history of cataract surgery prior to presentation were predictive of ongoing inflammation in adulthood in univariate analysis. The presence of hypotony and posterior synechiae at the initial visit were predictive factors in multivariate analysis. JIA-associated uveitis may be associated with ongoing inflammation, ocular complications, and severe visual impairment in adulthood. The presence of posterior synechiae and hypotony at the initial visit is predictive of ongoing inflammation.
Shwirl: Meaningful coloring of spectral cube data with volume rendering
NASA Astrophysics Data System (ADS)
Vohl, Dany
2017-04-01
Shwirl visualizes spectral data cubes with meaningful coloring methods. The program has been developed to investigate transfer functions, which combines volumetric elements (or voxels) to set the color, and graphics shaders, functions used to compute several properties of the final image such as color, depth, and/or transparency, as enablers for scientific visualization of astronomical data. The program uses Astropy (ascl:1304.002) to handle FITS files and World Coordinate System, Qt (and PyQt) for the user interface, and VisPy, an object-oriented Python visualization library binding onto OpenGL.
Ocular vascular occlusive disorders: Natural history of visual outcome☆
Hayreh, Sohan Singh
2014-01-01
Ocular vascular occlusive disorders collectively constitute the most common cause of visual disability. Before a disease can be managed, it is essential to understand its natural history, so as to be able to assess the likely effectiveness of any intervention. I investigated natural history of visual outcome in prospective studies of 386 eyes with non-arteritic anterior ischemic optic neuropathy (NA-AION), 16 eyes with non-arteritic posterior ischemic optic neuropathy, 697 eyes with central retinal vein occlusion (CRVO), 67 eyes with hemi-CRVO (HCRVO), 216 eyes with branch retinal vein occlusion (BRVO), 260 eyes with central retinal artery occlusion (CRAO), 151 eyes with branch retinal artery occlusion (BRAO) and 61 eyes with cilioretinal artery occlusion (CLRAO). My studies have shown that every one of these disorders consists of multiple distinct clinical sub-categories with different visual findings. When an ocular vascular occlusive disorder is caused by giant cell arteritis, which is an ophthalmic emergency, it would be unethical to do a natural history study of visual outcome in them, because in this case early diagnosis and immediate, intensive high-dose steroid therapy is essential to prevent any further visual loss, not only in the involved eye but also in the fellow, normal eye. In NA-AION in eyes seen ≤2 weeks after the onset, visual acuity (VA) improved in 41% of those with VA 20/70 or worse, and visual field (VF) improved in 26% of those with moderate to severe VF defect. In non-ischemic CRVO eyes with VA 20/70 or worse, VA improved in 47% and in ischemic CRVO in 23%; moderate to severe VF defect improved in 79% in non-ischemic CRVO and in 27% in ischemic CRVO. In HCRVO, overall findings demonstrated that initial VA and VF defect and the final visual outcome were different in non-ischemic from ischemic HCRVO – much better in the former than the latter. In major BRVO, in eyes with initial VA of 20/70 or worse, VA improved in 69%, and moderate to severe VF defect improved in 52%. In macular BRVO with 20/70 or worse initial VA, it improved in 53%, and initial minimal-mild VF defect was stable or improved in 85%. In various types of CRAO there are significant differences in both initial and final VA and VF defects. In CRAO eyes seen within 7 days of onset and initial VA of counting fingers or worse, VA improved in 82% with transient non-arteritic CRAO, 67% with non-arteritic CRAO with cilioretinal artery sparing, 22% with non-arteritic CRAO. Central VF improved in 39% of transient non-arteritic CRAO, 25% of non-arteritic CRAO with cilioretinal artery sparing and 21% of non-arteritic CRAO. Peripheral VF improved in non-arteritic CRAO in 39% and in transient non-arteritic CRAO in 39%. In transient CRAO, finally peripheral VFs were normal in 93%. In non-arteritic CRAO eyes initially 22% had normal peripheral VF and in the rest it improved in 39%. Final VA of 20/40 or better was seen in 89% of permanent BRAO, and in 100% of transient BRAO and non-arteritic CLRAO. In permanent BRAO eyes, among those seen within 7 days of onset, central VF defect improved in 47% and peripheral VF in 52%, and in transient BRAO central and peripheral VFs were normal at follow-up. My studies showed that AION, CRVO, BRVO, CRAO and BRAO, each consist of multiple distinct clinical sub-categories with different visual outcome. Contrary to the prevalent impression, these studies on the natural history of visual outcome have shown that there is a statistically significant spontaneous visual improvement in each category. The factors which influence the visual outcome in various ocular vascular occlusive disorders are discussed. PMID:24769221
75 FR 28058 - Certain Oil Country Tubular Goods From China; Determination
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-19
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1159 (Final)] Certain Oil Country Tubular... threatened with material injury by reason of imports from China of certain oil country tubular goods (``OCTG... are contained in USITC Publication 4152 (May 2010), entitled Certain Oil Country Tubular Goods From...
Development of Final Ecosystem Goods and Services Indicators for Estuaries and Coasts
Ecosystem services are those goods and services produced by the environment that benefit people. The concept aims to aid in the assessment of tradeoffs based on goods and services produced by the environment. Over the past seven years EPA has developed a framework for classificat...
Fledelius, Hans C; Bangsgaard, Regitze; Slidsborg, Carina; laCour, Morten
2015-06-01
A recent threefold increase in laser treatment for advanced retinopathy of prematurity (ROP) triggered a nationwide preschool ophthalmic and developmental status among extremely preterm survivors. Here, we discuss refraction and visual acuity. Survivors (n = 178) from a national birth cohort (February 2004 to March 2006) of gestational age <28 weeks (PT) and 56 full-term (FT) controls attended for evaluation at age 4 years. Cycloplegic refraction and keratometry were achieved by Retinomax autokeratorefractor and visual acuities by symbol recognition (HOTV, logMAR). The refractive distribution presented a myopic tail (4.5%) and a hyperopic tail (11.9% ≥+2.5 D) as special preterm features, and corneas were more curved. Astigmatism and anisometropia were only marginally increased, and visual acuities were generally good. Best-corrected binocular median logMAR visual acuity was 0.1 in FT and 0.2 in PT, in Snellen equivalents 0.8 and 0.63. Snellen acuity ≤0.5 occurred across the ROP subgroups, but mainly in those with at least ROP stage 3. Two children had low vision. The overall fair outcome for refraction and function is in accordance with other recent northern Europe experience. The results differ in particular from the poorer ophthalmic outcomes reported in the pioneer US treatment studies (cryotherapy for ROP and ETROP). The diode laser ablations (n = 32) appeared effective in our series; except one child, all treated subjects had good or fair social vision at the age of 4 years. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Proper poster presentation: a visual and verbal ABC.
Wright, V; Moll, J M
1987-08-01
The 58 posters exhibited at the 1985 Annual General Meeting of the British Society for Rheumatology have been analysed for 13 variables considered important in the construction of a good poster. In particular the attributes of information, simplicity and visual attractiveness were studied. The time spent by viewers was also measured for one selected poster each in immunology, biochemistry, therapeutics and clinical medicine. On the basis of this survey, nine recommendations for proper presentation were made.
Angioscopy by a new percutaneous transluminal coronary angioscope
NASA Astrophysics Data System (ADS)
Sakurada, Masami; Mizuno, Kyoichi; Miyamoto, Akira; Arakawa, Koh; Satomura, Kimio; Shibuya, Toshio; Yanagida, Shigeki; Okamoto, Yasuyuki; Kurita, Akira; Nakamura, Haruo; Arai, Tsunenori; Suda, Akira; Kikuchi, Makoto; Utsumi, Atsushi; Takeuchi, Kiyoshi; Akai, Yoshiro
1990-07-01
We developed a new percutaneous transluminal coronary angioscopic catheter for visualization of coronary artery.This angioscopic catheter has an inflatable balloon at the distal tip and one - directional angulation mechanism.We performed percutaneous transluminal coronary angioscopy during cardiac catheterization cosecutively in 155 patients. With this angioscope , we could get good'-'fair visualization in 81%(131 of 162 lesions)without major complications.We could investigate the endothelial macropathology of ischemic heart disease such as unstable angina and acute myocardial infarction.
[Subjective cognition in schizophrenia].
Potvin, S; Aubin, G; Stip, E
2017-02-01
Given the extent, magnitude and functional significance of the neurocognitive deficits of schizophrenia, growing attention has been paid recently to patients' self-awareness of their own deficits. Thus far, the literature has shown either that patients fail to recognize their cognitive deficits or that the association between subjective and objective cognition is weak in schizophrenia. The reasons for this lack of consistency remain unexplained but may have to do, among others, with the influence of potential confounding clinical variables and the choice of the scale used to measure self-awareness of cognitive deficits. In the current study, we sought to examine the relationships between subjective and objective cognitive performance in schizophrenia, while controlling for the influence of sociodemographic and psychiatric variables. Eighty-two patients with a schizophrenia-spectrum disorder (DSM-IV criteria) were recruited. Patients' subjective cognitive complaints were evaluated with the Subjective Scale to Investigate Cognition in Schizophrenia (SSTICS), the most frequently used scale to measure self-awareness of cognitive deficits in schizophrenia. Neurocognition was evaluated with working memory, planning and visual learning tasks taken from Cambridge Neuropsychological Tests Automated Battery. The Stroop Color-Word test was also administered. Psychiatric symptoms were evaluated with the Positive and Negative Syndrome Scale and the Calgary Depression Scale for Schizophrenia. The relationships between subjective and objective cognition were evaluated with multivariate hierarchic linear regression analyses, taking into consideration potential confounders such as sociodemographic and psychiatric variables. Finally, a factor analysis of the SSTICS was performed. For the SSTICS total score, the regression analysis produced a model including two predictors, namely visual learning and Stoop interference performance, explaining a moderate portion of the variance. Visual learning performance was the most consistent predictor of most SSTICS subscores (e.g. episodic memory, attention, executive functioning, language and praxis). Modest associations were found between the PANSS cognitive factor and objective cognition (e.g. Stroop interference, visual learning, and working memory). Finally, the factor analysis revealed a 6-factor solution that echoes the classification of the items of the SSTICS based on the neuropsychological literature. Using a scale having good internal validity, as shown by the factor analysis, the current study highlighted modest associations between subjective and objective cognitive performance, which suggests that schizophrenia patients are only partially aware of their own cognitive deficits. The results also showed a lack of correspondence between the impaired cognitive domain and the domain of cognitive awareness. It should be noted that clinicians were not better than patients at evaluating their cognitive deficits. Future research will need to determine if the observations reported here are schizophrenia-specific or not. Copyright © 2016 L'Encéphale, Paris. Published by Elsevier Masson SAS. All rights reserved.
Drivers of U.S. mineral demand
Sznopek, John L.
2006-01-01
Introduction: The word 'demand' has different meanings for different people. To some, it means their 'wants and needs,' to others it is what they consume. Yet, when considering economics, demand refers to the specific amounts of goods or services that individuals will purchase at various prices. Demand is measured over a given time period. It is determined by a number of factors including income, tastes, and the price of complementary and substitute goods. In this paper, the term consumption is used fairly synonymously with the term demand. Most mineral commodities, like iron ore, copper, zinc, and gravel, are intermediate goods, which means that they are used in the production of other goods, called final goods. Demand for intermediate goods is called derived demand because such demand is derived from the demand for final goods. When demand increases for a commodity, generally the price rises. With everything else held constant, this increases the profits for those who provide this commodity. Normally, this would increase profits of existing producers and attract new producers to the market. When demand for a commodity decreases, generally the price falls. Normally, this would cause profits to fall and, as a consequence, the least efficient firms may be forced from the industry. Demand changes for specific materials as final goods or production techniques are reengineered while maintaining or improving product performance, for example, the use of aluminum in the place of copper in long distance electrical transmission lines or plastic replacing steel in automobile bumpers. Substitution contributes to efficient material usage by utilizing cheaper or technically superior materials. In this way, it may also alleviate materials scarcity. If a material becomes relatively scarce (and thus more expensive), a more abundant (and less expensive) material generally replaces it (Wagner and others, 2003, p. 91).
Toy, Brian C; Myung, David J; He, Lingmin; Pan, Carolyn K; Chang, Robert T; Polkinhorne, Alison; Merrell, Douglas; Foster, Doug; Blumenkranz, Mark S
2016-05-01
To compare clinical assessment of diabetic eye disease by standard dilated examination with data gathered using a smartphone-based store-and-forward teleophthalmology platform. 100 eyes of 50 adult patients with diabetes from a health care safety-net ophthalmology clinic. All patients underwent comprehensive ophthalmic examination. Concurrently, a smartphone was used to estimate near visual acuity and capture anterior and dilated posterior segment photographs, which underwent masked, standardized review. Quantitative comparison of clinic and smartphone-based data using descriptive, kappa, Bland-Altman, and receiver operating characteristic analyses was performed. Smartphone visual acuity was successfully measured in all eyes. Anterior and posterior segment photography was of sufficient quality to grade in 96 and 98 eyes, respectively. There was good correlation between clinical Snellen and smartphone visual acuity measurements (rho = 0.91). Smartphone-acquired fundus photographs demonstrated 91% sensitivity and 99% specificity to detect moderate nonproliferative and worse diabetic retinopathy, with good agreement between clinic and photograph grades (kappa = 0.91 ± 0.1, P < 0.001; AUROC = 0.97, 95% confidence interval, 0.93-1). The authors report a smartphone-based telemedicine system that demonstrated sensitivity and specificity to detect referral-warranted diabetic eye disease as a proof-of-concept. Additional studies are warranted to evaluate this approach to expanding screening for diabetic retinopathy.
Whatman, Chris; Hing, Wayne; Hume, Patria
2012-05-01
To investigate physiotherapist agreement in rating movement quality during lower extremity functional tests using two visual rating methods and physiotherapists with differing clinical experience. Clinical measurement. Six healthy individuals were rated by 44 physiotherapists. These raters were in three groups (inexperienced, novice, experienced). Video recordings of all six individuals performing four lower extremity functional tests were visually rated (dichotomous or ordinal scale) using two rating methods (overall or segment) on two occasions separated by 3-4 weeks. Intra and inter-rater agreement for physiotherapists was determined using overall percentage agreement (OPA) and the first order agreement coefficient (AC1). Intra-rater agreement for overall and segment methods ranged from slight to almost perfect (OPA: 29-96%, AC1: 0.01 to 0.96). AC1 agreement was better in the experienced group (84-99% likelihood) and for dichotomous rating (97-100% likelihood). Inter-rater agreement ranged from fair to good (OPA: 45-79%; AC1: 0.22-0.71). AC1 agreement was not influenced by clinical experience but was again better using dichotomous rating. Physiotherapists' visual rating of movement quality during lower extremity functional tests resulted in slight to almost perfect intra-rater agreement and fair to good inter-rater agreement. Agreement improved with increased level of clinical experience and use of dichotomous rating. Copyright © 2011 Elsevier Ltd. All rights reserved.
Bakić-Mirić, Natasa
2010-01-01
Theory of multiple intelligences (MI) is considered an innovation in learning the English language because it helps students develop all eight intelligences that, on the other hand, represent ways people understand the world around them, solve problems and learn. They are: verbal/linguistic, logical/mathematical, visual/spatial, bodily/kinaesthetic, musical/rhythmic, interpersonal, intrapersonal and naturalist. Also, by focusing on the problem-solving activities, teachers, by implementing theory of multiple intelligences, encourage students not only to build their existing language knowledge but also learn new content and skills. The objective of this study has been to determine the importance of implementation of the theory of multiple intelligences in the English language course syllabus at the University of Nis Medical School. Ways in which the theory of multiple intelligences has been implemented in the English language course syllabus particularly in one lecture for junior year students of pharmacy in the University of Nis Medical School. The English language final exam results from February 2009 when compared with the final exam results from June 2007 prior to the implementation of MI theory showed the following: out of 80 junior year students of pharmacy, 40 obtained grade 10 (outstanding), 16 obtained grade 9 (excellent), 11 obtained grade 8 (very good), 4 obtained grade 7 (good) and 9 obtained grade 6 (pass). No student failed. The implementation of the theory of multiple intelligences in the English language course syllabus at the University of Nis Medical School has had a positive impact on learning the English language and has increased students' interest in language learning. Genarally speaking, this theory offers better understanding of students' intelligence and greater appreciation of their strengths. It provides numerous opportunities for students to use and develop all eight intelligences not just the few they excel in prior to enrolling in a university or college.
Yao, Min; Yang, Long; Cao, Zuo-Yuan; Cheng, Shao-Dan; Tian, Shuang-Lin; Sun, Yue-Li; Wang, Jing; Xu, Bao-Ping; Hu, Xiao-Chun; Wang, Yong-Jun; Zhang, Ying; Cui, Xue-Jun
2017-09-18
Shoulder pain is a common musculoskeletal disorder in Chinese population, which affects more than 1,3 billion individuals. To the best of our knowledge, there has been no available Chinese-language version of measurements of shoulder pain and disability so far. Moreover, the Constant-Murley score (CMS) questionnaire is a universally recognized patient-reported questionnaire for clinical practice and research. The present study was designed to evaluate a Chinese translational version of CMS and subsequently assess its reliability and validity. The Chinese translational version of CMS was formulated by means of forward-backward translation. Meanwhile, a final review was carried out by an expert committee, followed by conducting a test of the pre-final version. Therefore, the reliability and validity of the Chinese translational version of CMS could be assessed using the internal consistency, construct validity, factor analysis, reliability and floor and ceiling effects. Specifically, the reliability was assessed by testing the internal consistency (Cronbach's α) and test-retest reliability (intraclass coefficient correlation [ICC]), while the construct validity was evaluated via comparison between the Chinese translational version of CMS with visual analog scale (VAS) score and the 36-Item Short Form Health Survey (SF-36, Spearman correlation). The questionnaire was verified to be acceptable after distribution among 120 subjects with unilateral shoulder pain. Factor analysis had revealed a two-factor and 10-item solution. Moreover, the assessment results indicated that the Chinese translational version of CMS questionnaire harbored good internal consistency (Cronbach's α = 0.739) and test-retest reliability (ICC = 0.827). In addition, the Chinese translational version of CMS was moderately correlated with VAS score (r = 0.497) and SF-36 (r = 0.135). No obvious floor and ceiling effects were observed in the Chinese translational version of CMS questionnaire. Chinese translational version of CMS exhibited good reliability, which is relatively acceptable and is likely to be widely used in this population.
Srinivasan, Nithin Keshav; John, Deepa; Rebekah, Grace; Kujur, Evon Selina; Paul, Padma
2017-01-01
Introduction Diabetic retinopathy is becoming an increasingly important cause of visual impairment in India. Many diabetic patients who come to our centre have undetected, advanced diabetic retinopathy. If diabetic retinopathy had been detected earlier in these patients, irreversible visual impairment could have been prevented. Aim To document Knowledge, Attitude and Practice (KAP) patterns of diabetic patients regarding diabetes and diabetic retinopathy, to determine association between them, and to identify barriers to compliance with follow up and treatment regimes. Materials and Methods This was a hospital-based, cross-sectional study, conducted at the Department of Ophthalmology at Christian Medical College, Vellore, Tamil Nadu, India, over a six-month period from June 2013 to November 2013. Two hundred and eighty eight diabetic patients, who fulfilled the eligibility criteria, were included in the study. KAP of patients was assessed using a 45-point, verbally administered questionnaire. Patients were placed in different categories, such as, ‘good/ poor’ knowledge, ‘positive/negative’ attitude and ‘good/poor’ practice. Data were analysed using Chi-square test and binary logistic regression, as appropriate. The proportion of patients with ‘good/poor’ knowledge, ‘positive/negative’ attitude and ‘good/poor’ practice, and the association between KAP were studied. Barriers to compliance with follow up/treatment regimes were identified. Results Out of the 288 patients in the study, 42% had good knowledge about diabetes, but only 4.5% had good knowledge about retinopathy. Good knowledge about diabetes was significantly associated with positive attitude towards diabetes and good practice patterns regarding retinopathy; awareness of retinopathy was also significantly associated with good practice. A total of 61.1% of patients did not have periodic eye examination; most common barrier identified was lack of awareness about the necessity for this (38.5%). Conclusion Good knowledge about the disease was significantly associated with positive attitude and good practice patterns. Knowledge about diabetic retinopathy was poor among the patients in our study. Lack of awareness concerning the need for screening for retinopathy was a major barrier to regular screening. There is an urgent need to educate diabetic patients about this potentially blinding complication of diabetes. PMID:28892947
Visual function and fitness to drive.
Kotecha, Aachal; Spratt, Alexander; Viswanathan, Ananth
2008-01-01
Driving is recognized to be a visually intensive task and accordingly there is a legal minimum standard of vision required for all motorists. The purpose of this paper is to review the current United Kingdom (UK) visual requirements for driving and discuss the evidence base behind these legal rules. The role of newer, alternative tests of visual function that may be better indicators of driving safety will also be considered. Finally, the implications of ageing on driving ability are discussed. A search of Medline and PubMed databases was performed using the following keywords: driving, vision, visual function, fitness to drive and ageing. In addition, papers from the Department of Transport website and UK Royal College of Ophthalmologists guidelines were studied. Current UK visual standards for driving are based upon historical concepts, but recent advances in technology have brought about more sophisticated methods for assessing the status of the binocular visual field and examining visual attention. These tests appear to be better predictors of driving performance. Further work is required to establish whether these newer tests should be incorporated in the current UK visual standards when examining an individual's fitness to drive.
Donor lung assessment using selective pulmonary vein gases.
Costa, Joseph; Sreekanth, Sowmyashree; Kossar, Alex; Raza, Kashif; Lederer, David J; Robbins, Hilary; Shah, Lori; Sonett, Joshua R; Arcasoy, Selim; D'Ovidio, Frank
2016-11-01
Standard donor lung assessment relies on imaging, challenge gases and subjective interpretation of bronchoscopic findings, palpation and visual assessment. Central gases may not accurately represent true quality of the lungs. We report our experience using selective pulmonary vein gases to corroborate the subjective judgement. Starting, January 2012, donor lungs have been assessed by intraoperative bronchoscopy, palpation and visual judgement of lung collapse upon temporary disconnection from ventilator, central gases from the aorta and selective pulmonary vein gases. Partial pressure of oxygen (pO 2 ) <300 mmHg on FiO 2 of 1.0 was considered low. The results of the chest X-ray and last pO 2 in the intensive care unit were also collected. Post-transplant primary graft dysfunction and survival were monitored. To date, 259 consecutive brain-dead donors have been assessed and 157 transplants performed. Last pO 2 in the intensive care unit was poorly correlated with intraoperative central pO 2 (Spearman's rank correlation r s = 0.29). Right inferior pulmonary vein pO 2 was associated (Mann-Whitney, P < 0.001) with findings at bronchoscopy [clean: median pO 2 443 mmHg (25th-75th percentile range 349-512) and purulent: 264 mmHg (178-408)]; palpation [good: 463 mmHg (401-517) and poor: 264 mmHg (158-434)] and visual assessment of lung collapse [good lung collapse: 429 mmHg (320-501) and poor lung collapse: 205 mmHg (118-348)]. Left inferior pulmonary pO 2 was associated (P < 0.001) with findings at bronchoscopy [clean: 419 mmHg (371-504) and purulent: 254 mmHg (206-367)]; palpation [good: 444 mmHg (400-517) and poor 282 mmHg (211-419)] and visual assessment of lung collapse [good: 420 mmHg (349-496) and poor: 246 mmHg (129-330)]. At 72 h, pulmonary graft dysfunction 2 was in 21/157 (13%) and pulmonary graft dysfunction 3 in 17/157 (11%). Ninety-day and 1-year mortalities were 6/157 (4%) and 13/157 (8%), respectively. Selective pulmonary vein gases provide corroborative objective support to the findings at bronchoscopy, palpation and visual assessment. Central gases do not always reflect true function of the lungs, having high false-positive rate towards the individual lower lobe gas exchange. Objective measures of donor lung function may optimize donor surgeon assessment, allowing for low pulmonary graft dysfunction rates and low 90-day and 1-year mortality. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
An Approach of Web-based Point Cloud Visualization without Plug-in
NASA Astrophysics Data System (ADS)
Ye, Mengxuan; Wei, Shuangfeng; Zhang, Dongmei
2016-11-01
With the advances in three-dimensional laser scanning technology, the demand for visualization of massive point cloud is increasingly urgent, but a few years ago point cloud visualization was limited to desktop-based solutions until the introduction of WebGL, several web renderers are available. This paper addressed the current issues in web-based point cloud visualization, and proposed a method of web-based point cloud visualization without plug-in. The method combines ASP.NET and WebGL technologies, using the spatial database PostgreSQL to store data and the open web technologies HTML5 and CSS3 to implement the user interface, a visualization system online for 3D point cloud is developed by Javascript with the web interactions. Finally, the method is applied to the real case. Experiment proves that the new model is of great practical value which avoids the shortcoming of the existing WebGIS solutions.
The Role of Eye Movement Driven Attention in Functional Strabismic Amblyopia
2015-01-01
Strabismic amblyopia “blunt vision” is a developmental anomaly that affects binocular vision and results in lowered visual acuity. Strabismus is a term for a misalignment of the visual axes and is usually characterized by impaired ability of the strabismic eye to take up fixation. Such impaired fixation is usually a function of the temporally and spatially impaired binocular eye movements that normally underlie binocular shifts in visual attention. In this review, we discuss how abnormal eye movement function in children with misaligned eyes influences the development of normal binocular visual attention and results in deficits in visual function such as depth perception. We also discuss how eye movement function deficits in adult amblyopia patients can also lead to other abnormalities in visual perception. Finally, we examine how the nonamblyopic eye of an amblyope is also affected in strabismic amblyopia. PMID:25838941
Cortical visual prostheses: from microstimulation to functional percept
NASA Astrophysics Data System (ADS)
Najarpour Foroushani, Armin; Pack, Christopher C.; Sawan, Mohamad
2018-04-01
Cortical visual prostheses are intended to restore vision by targeted electrical stimulation of the visual cortex. The perception of spots of light, called phosphenes, resulting from microstimulation of the visual pathway, suggests the possibility of creating meaningful percept made of phosphenes. However, to date electrical stimulation of V1 has still not resulted in perception of phosphenated images that goes beyond punctate spots of light. In this review, we summarize the clinical and experimental progress that has been made in generating phosphenes and modulating their associated perceptual characteristics in human and macaque primary visual cortex (V1). We focus specifically on the effects of different microstimulation parameters on perception and we analyse key challenges facing the generation of meaningful artificial percepts. Finally, we propose solutions to these challenges based on the application of supervised learning of population codes for spatial stimulation of visual cortex.
Dynamic and predictive links between touch and vision.
Gray, Rob; Tan, Hong Z
2002-07-01
We investigated crossmodal links between vision and touch for moving objects. In experiment 1, observers discriminated visual targets presented randomly at one of five locations on their forearm. Tactile pulses simulating motion along the forearm preceded visual targets. At short tactile-visual ISIs, discriminations were more rapid when the final tactile pulse and visual target were at the same location. At longer ISIs, discriminations were more rapid when the visual target was offset in the motion direction and were slower for offsets opposite to the motion direction. In experiment 2, speeded tactile discriminations at one of three random locations on the forearm were preceded by a visually simulated approaching object. Discriminations were more rapid when the object approached the location of the tactile stimulation and discrimination performance was dependent on the approaching object's time to contact. These results demonstrate dynamic links in the spatial mapping between vision and touch.
Visualizando el desarrollo de la nanomedicina en México.
Robles-Belmont, Eduardo; Gortari-Rabiela, Rebeca de; Galarza-Barrios, Pilar; Siqueiros-García, Jesús Mario; Ruiz-León, Alejandro Arnulfo
2017-01-01
In this article we present a set of different visualizations of Mexico's nanomedicine scientific production data. Visualizations were developed using different methodologies for data analysis and visualization such as social network analysis, geography of science maps, and complex network communities analysis. Results are a multi-dimensional overview of the evolution of nanomedicine in Mexico. Moreover, visualizations allowed to identify trends and patterns of collaboration at the national and international level. Trends are also found in the knowledge structure of themes and disciplines. Finally, we identified the scientific communities in Mexico that are responsible for the new knowledge production in this emergent field of science. Copyright: © 2017 SecretarÍa de Salud
1984-09-01
Inhalation Toxicology, Mehlman, Crammer , and Shapiro, editors, 302-344, Pathotox Publishers, Inc., Park Forest South, Illinois (1977). 8. Shimkin, M. and G...Laboratory Studies. (3) Final Rule , Pesticide Programs; Good Laboratory Practice Standards; 48 Federal Register (FR) 53963-53969, 29 November 1983. (4...Final Rule , Toxic Substances Control; Good Laboratory Practice Standards; 48 Federal Register (FR) 53922-53944, 29 November 1983. b. Facilities were
SnopViz, an interactive snow profile visualization tool
NASA Astrophysics Data System (ADS)
Fierz, Charles; Egger, Thomas; gerber, Matthias; Bavay, Mathias; Techel, Frank
2016-04-01
SnopViz is a visualization tool for both simulation outputs of the snow-cover model SNOWPACK and observed snow profiles. It has been designed to fulfil the needs of operational services (Swiss Avalanche Warning Service, Avalanche Canada) as well as offer the flexibility required to satisfy the specific needs of researchers. This JavaScript application runs on any modern browser and does not require an active Internet connection. The open source code is available for download from models.slf.ch where examples can also be run. Both the SnopViz library and the SnopViz User Interface will become a full replacement of the current research visualization tool SN_GUI for SNOWPACK. The SnopViz library is a stand-alone application that parses the provided input files, for example, a single snow profile (CAAML file format) or multiple snow profiles as output by SNOWPACK (PRO file format). A plugin architecture allows for handling JSON objects (JavaScript Object Notation) as well and plugins for other file formats may be added easily. The outputs are provided either as vector graphics (SVG) or JSON objects. The SnopViz User Interface (UI) is a browser based stand-alone interface. It runs in every modern browser, including IE, and allows user interaction with the graphs. SVG, the XML based standard for vector graphics, was chosen because of its easy interaction with JS and a good software support (Adobe Illustrator, Inkscape) to manipulate graphs outside SnopViz for publication purposes. SnopViz provides new visualization for SNOWPACK timeline output as well as time series input and output. The actual output format for SNOWPACK timelines was retained while time series are read from SMET files, a file format used in conjunction with the open source data handling code MeteoIO. Finally, SnopViz is able to render single snow profiles, either observed or modelled, that are provided as CAAML-file. This file format (caaml.org/Schemas/V5.0/Profiles/SnowProfileIACS) is an international standard to exchange snow profile data. It is supported by the International Association of Cryospheric Sciences (IACS) and was developed in collaboration with practitioners (Avalanche Canada).
Visual outcomes and prognostic factors in open-globe injuries.
Fujikawa, Azusa; Mohamed, Yasser Helmy; Kinoshita, Hirofumi; Matsumoto, Makiko; Uematsu, Masafumi; Tsuiki, Eiko; Suzuma, Kiyoshi; Kitaoka, Takashi
2018-06-08
Ocular trauma is an important cause of visual loss worldwide. Improvements in our knowledge of the pathophysiology and management of ocular trauma during the past 30 years, in conjunction with advances in the instrumentation and techniques of ocular surgery, have improved the efficacy of vitreoretinal surgery in injured eyes. The aim of the current study was to determine the visual outcomes and prognostic factors of open-globe injuries in the Japanese population. Retrospective study of 59 eyes of 59 patients presented with open globe injuries between September 2008 and March 2014 at Nagasaki University Hospital was conducted. Demographic factors including age, gender, and clinical data such as cause of injury, presenting visual acuity (VA), location of injury, type of injury, lens status, presence of intraocular foreign body, types of required surgeries, and final VA were recorded. According to the classification of Ocular Trauma Classification Group, wound location was classified into three zones. Chi-square test was used to compare presented data. Out of the 59 patients, 46 were placed in the Light Perception (LP) group, and 13 were placed in the No Light Perception (NLP) group. Work-related trauma was the most common cause (27 eyes) followed by falls (19eyes). Work-related trauma was common in males (P = 0.004), while falls was significantly common in females (P = 0.00001). Zone III injuries had statistically significantly poor prognostic factor compared to other zones (P = 0.04). All cases of NLP group (100%) presented with rupture globe. Poor VA at first visit (P = 0.00001), rupture globe (P = 0.026), history of penetrating keratoplasty (PK) (P = 0.017), retinal detachment (RD) (P = 0.0001), vitreous hemorrhage (VH) (P = 0.044), and dislocation of crystalline lens (P = 0.0003) were considered as poor prognostic factors. Poor VA at first visit, rupture globe, zone III injuries, history of penetrating keratoplasty, RD, VH, and dislocation of crystalline lens were found to be poor prognostic factors. PPV had a good prognostic value in open globe injuries associated with posterior segment involvement.
Determining the inertial states of low Prandtl number fluids using electrochemical cells
NASA Astrophysics Data System (ADS)
Crunkleton, Daniel Wray
The quality of crystals grown from the melt is often deteriorated by the presence of buoyancy-induced convection, produced by temperature or concentration inhomogenities. It is, therefore, important to develop techniques to visualize such flows. In this study, a novel technique is developed that uses solid-state electrochemical cells to establish and measure dissolved oxygen boundary conditions. To visualize convection, a packet of oxygen is electrochemically introduced at a specific location in the melt. As the fluid convects, this oxygen packet follows the flow, acting as a tracer. Electrochemical sensors located along the enclosure then detect the oxygen as it passes. Over sufficiently long times, oxygen diffusion is important; consequently, the oxygen diffusivity in the fluid is measured. This diffusivity is determined using both transient and steady state experiments with tin and tin-lead alloys as model fluids. It is concluded that the presence of convection due to solutal gradients and/or tilt increases the measured diffusivity by one-half to one order of magnitude. The oxygen diffusivity in tin-lead alloys is measured and the results show that the alloy diffusivities are lower than those of the corresponding pure metals. This concentration functionality is explained with a multicomponent diffusion model and shows good agreement. Rayleigh-Benard convection was used to validate the electrochemical approach to flow visualization. Thus, a numerical characterization of the second critical Rayleigh numbers in liquid tin was conducted for a variety of Cartesian aspect ratios. The extremely low Prandtl number of tin represents the lowest value studied numerically. Additionally, flow field oscillations are visualized and the effect of tilt on convecting systems is quantified. Finally, experimental studies of the effect of convection in liquid tin are presented. Three geometries are studied: (1) double cell with vertical concentration gradients; (2) double cell with horizontal concentration gradients; and (3) multiple cell with vertical temperature gradients. The first critical Rayleigh number transition is detected with geometry (1) and it is concluded that current measurements are not as affected by convection as EMF measurements. The system is compared with numerical simulations in geometry (2), and oscillating convection is detected with geometry (3).
Visualization Improves Supraclavicular Access to the Subclavian Vein in a Mixed Reality Simulator.
Sappenfield, Joshua Warren; Smith, William Brit; Cooper, Lou Ann; Lizdas, David; Gonsalves, Drew B; Gravenstein, Nikolaus; Lampotang, Samsun; Robinson, Albert R
2018-07-01
We investigated whether visual augmentation (3D, real-time, color visualization) of a procedural simulator improved performance during training in the supraclavicular approach to the subclavian vein, not as widely known or used as its infraclavicular counterpart. To train anesthesiology residents to access a central vein, a mixed reality simulator with emulated ultrasound imaging was created using an anatomically authentic, 3D-printed, physical mannequin based on a computed tomographic scan of an actual human. The simulator has a corresponding 3D virtual model of the neck and upper chest anatomy. Hand-held instruments such as a needle, an ultrasound probe, and a virtual camera controller are directly manipulated by the trainee and tracked and recorded with submillimeter resolution via miniature, 6 degrees of freedom magnetic sensors. After Institutional Review Board approval, 69 anesthesiology residents and faculty were enrolled and received scripted instructions on how to perform subclavian venous access using the supraclavicular approach based on anatomic landmarks. The volunteers were randomized into 2 cohorts. The first used real-time 3D visualization concurrently with trial 1, but not during trial 2. The second did not use real-time 3D visualization concurrently with trial 1 or 2. However, after trial 2, they observed a 3D visualization playback of trial 2 before performing trial 3 without visualization. An automated scoring system based on time, success, and errors/complications generated objective performance scores. Nonparametric statistical methods were used to compare the scores between subsequent trials, differences between groups (real-time visualization versus no visualization versus delayed visualization), and improvement in scores between trials within groups. Although the real-time visualization group demonstrated significantly better performance than the delayed visualization group on trial 1 (P = .01), there was no difference in gain scores, between performance on the first trial and performance on the final trial, that were dependent on group (P = .13). In the delayed visualization group, the difference in performance between trial 1 and trial 2 was not significant (P = .09); reviewing performance on trial 2 before trial 3 resulted in improved performance when compared to trial 1 (P < .0001). There was no significant difference in median scores (P = .13) between the real-time visualization and delayed visualization groups for the last trial after both groups had received visualization. Participants reported a significant improvement in confidence in performing supraclavicular access to the subclavian vein. Standard deviations of scores, a measure of performance variability, decreased in the delayed visualization group after viewing the visualization. Real-time visual augmentation (3D visualization) in the mixed reality simulator improved performance during supraclavicular access to the subclavian vein. No difference was seen in the final trial of the group that received real-time visualization compared to the group that had delayed visualization playback of their prior attempt. Training with the mixed reality simulator improved participant confidence in performing an unfamiliar technique.
SABER: Airland Combat Training Model Credibility Assessment and Methodology
1992-03-01
The three types of weather are good, VFR conditions (visual flight rules); fair , MVFR (marginal VFR), and; poor, IFR conditions (instrument flight rules...categories good, fair and poor represent VFR, MVFR and IFR flight conditions respectively. Darkness can be thought of as an attribute of weather, that... fair , poor, or very poor (VP). The meaning of these values were explained in section 4.3.5. Another value , called impassible (IMP), should be added to
Harn, Nicholas R; Hunt, Suzanne L; Hill, Jacqueline; Vidoni, Eric; Perry, Mark; Burns, Jeffrey M
2017-08-01
Establishing reliable methods for interpreting elevated cerebral amyloid-β plaque on PET scans is increasingly important for radiologists, as availability of PET imaging in clinical practice increases. We examined a 3-step method to detect plaque in cognitively normal older adults, focusing on the additive value of quantitative information during the PET scan interpretation process. Fifty-five F-florbetapir PET scans were evaluated by 3 experienced raters. Scans were first visually interpreted as having "elevated" or "nonelevated" plaque burden ("Visual Read"). Images were then processed using a standardized quantitative analysis software (MIMneuro) to generate whole brain and region of interest SUV ratios. This "Quantitative Read" was considered elevated if at least 2 of 6 regions of interest had an SUV ratio of more than 1.1. The final interpretation combined both visual and quantitative data together ("VisQ Read"). Cohen kappa values were assessed as a measure of interpretation agreement. Plaque was elevated in 25.5% to 29.1% of the 165 total Visual Reads. Interrater agreement was strong (kappa = 0.73-0.82) and consistent with reported values. Quantitative Reads were elevated in 45.5% of participants. Final VisQ Reads changed from initial Visual Reads in 16 interpretations (9.7%), with most changing from "nonelevated" Visual Reads to "elevated." These changed interpretations demonstrated lower plaque quantification than those initially read as "elevated" that remained unchanged. Interrater variability improved for VisQ Reads with the addition of quantitative information (kappa = 0.88-0.96). Inclusion of quantitative information increases consistency of PET scan interpretations for early detection of cerebral amyloid-β plaque accumulation.
Temporal and spatial localization of prediction-error signals in the visual brain.
Johnston, Patrick; Robinson, Jonathan; Kokkinakis, Athanasios; Ridgeway, Samuel; Simpson, Michael; Johnson, Sam; Kaufman, Jordy; Young, Andrew W
2017-04-01
It has been suggested that the brain pre-empts changes in the environment through generating predictions, although real-time electrophysiological evidence of prediction violations in the domain of visual perception remain elusive. In a series of experiments we showed participants sequences of images that followed a predictable implied sequence or whose final image violated the implied sequence. Through careful design we were able to use the same final image transitions across predictable and unpredictable conditions, ensuring that any differences in neural responses were due only to preceding context and not to the images themselves. EEG and MEG recordings showed that early (N170) and mid-latency (N300) visual evoked potentials were robustly modulated by images that violated the implied sequence across a range of types of image change (expression deformations, rigid-rotations and visual field location). This modulation occurred irrespective of stimulus object category. Although the stimuli were static images, MEG source reconstruction of the early latency signal (N/M170) localized expectancy violation signals to brain areas associated with motion perception. Our findings suggest that the N/M170 can index mismatches between predicted and actual visual inputs in a system that predicts trajectories based on ongoing context. More generally we suggest that the N/M170 may reflect a "family" of brain signals generated across widespread regions of the visual brain indexing the resolution of top-down influences and incoming sensory data. This has important implications for understanding the N/M170 and investigating how the brain represents context to generate perceptual predictions. Copyright © 2017 Elsevier B.V. All rights reserved.
Color-Space-Based Visual-MIMO for V2X Communication †
Kim, Jai-Eun; Kim, Ji-Won; Park, Youngil; Kim, Ki-Doo
2016-01-01
In this paper, we analyze the applicability of color-space-based, color-independent visual-MIMO for V2X. We aim to achieve a visual-MIMO scheme that can maintain the original color and brightness while performing seamless communication. We consider two scenarios of GCM based visual-MIMO for V2X. One is a multipath transmission using visual-MIMO networking and the other is multi-node V2X communication. In the scenario of multipath transmission, we analyze the channel capacity numerically and we illustrate the significance of networking information such as distance, reference color (symbol), and multiplexing-diversity mode transitions. In addition, in the V2X scenario of multiple access, we may achieve the simultaneous multiple access communication without node interferences by dividing the communication area using image processing. Finally, through numerical simulation, we show the superior SER performance of the visual-MIMO scheme compared with LED-PD communication and show the numerical result of the GCM based visual-MIMO channel capacity versus distance. PMID:27120603
Color-Space-Based Visual-MIMO for V2X Communication.
Kim, Jai-Eun; Kim, Ji-Won; Park, Youngil; Kim, Ki-Doo
2016-04-23
In this paper, we analyze the applicability of color-space-based, color-independent visual-MIMO for V2X. We aim to achieve a visual-MIMO scheme that can maintain the original color and brightness while performing seamless communication. We consider two scenarios of GCM based visual-MIMO for V2X. One is a multipath transmission using visual-MIMO networking and the other is multi-node V2X communication. In the scenario of multipath transmission, we analyze the channel capacity numerically and we illustrate the significance of networking information such as distance, reference color (symbol), and multiplexing-diversity mode transitions. In addition, in the V2X scenario of multiple access, we may achieve the simultaneous multiple access communication without node interferences by dividing the communication area using image processing. Finally, through numerical simulation, we show the superior SER performance of the visual-MIMO scheme compared with LED-PD communication and show the numerical result of the GCM based visual-MIMO channel capacity versus distance.
Students using visual thinking to learn science in a Web-based environment
NASA Astrophysics Data System (ADS)
Plough, Jean Margaret
United States students' science test scores are low, especially in problem solving, and traditional science instruction could be improved. Consequently, visual thinking, constructing science structures, and problem solving in a web-based environment may be valuable strategies for improving science learning. This ethnographic study examined the science learning of fifteen fourth grade students in an after school computer club involving diverse students at an inner city school. The investigation was done from the perspective of the students, and it described the processes of visual thinking, web page construction, and problem solving in a web-based environment. The study utilized informal group interviews, field notes, Visual Learning Logs, and student web pages, and incorporated a Standards-Based Rubric which evaluated students' performance on eight science and technology standards. The Visual Learning Logs were drawings done on the computer to represent science concepts related to the Food Chain. Students used the internet to search for information on a plant or animal of their choice. Next, students used this internet information, with the information from their Visual Learning Logs, to make web pages on their plant or animal. Later, students linked their web pages to form Science Structures. Finally, students linked their Science Structures with the structures of other students, and used these linked structures as models for solving problems. Further, during informal group interviews, students answered questions about visual thinking, problem solving, and science concepts. The results of this study showed clearly that (1) making visual representations helped students understand science knowledge, (2) making links between web pages helped students construct Science Knowledge Structures, and (3) students themselves said that visual thinking helped them learn science. In addition, this study found that when using Visual Learning Logs, the main overall ideas of the science concepts were usually represented accurately. Further, looking for information on the internet may cause new problems in learning. Likewise, being absent, starting late, and/or dropping out all may negatively influence students' proficiency on the standards. Finally, the way Science Structures are constructed and linked may provide insights into the way individual students think and process information.
NASA Astrophysics Data System (ADS)
Matuk, Camillia Faye
Visual representations are central to expert scientific thinking. Meanwhile, novices tend toward narrative conceptions of scientific phenomena. Until recently, however, relationships between visual design, narrative thinking, and their impacts on learning science have only been theoretically pursued. This dissertation first synthesizes different disciplinary perspectives, then offers a mixed-methods investigation into interpretations of scientific representations. Finally, it considers design issues associated with narrative and visual imagery, and explores the possibilities of a pedagogical notation to scaffold the understanding of a standard scientific notation. Throughout, I distinguish two categories of visual media by their relation to narrative: Narrative visual media, which convey content via narrative structure, and Conceptual visual media, which convey states of relationships among objects. Given the role of narrative in framing conceptions of scientific phenomena and perceptions of its representations, I suggest that novices are especially prone to construe both kinds of media in narrative terms. To illustrate, I first describe how novices make meaning of the science conveyed in narrative visual media. Vignettes of an undergraduate student's interpretation of a cartoon about natural selection; and of four 13-year olds' readings of a comic book about human papillomavirus infection, together demonstrate conditions under which designed visual narrative elements facilitate or hinder understanding. I next consider the interpretation of conceptual visual media with an example of an expert notation from evolutionary biology, the cladogram. By combining clinical interview methods with experimental design, I show how undergraduate students' narrative theories of evolution frame perceptions of the diagram (Study 1); I demonstrate the flexibility of symbolic meaning, both with the content assumed (Study 2A), and with alternate manners of presenting the diagram (Study 2B); finally, I show the effects of content assumptions on the diagrams students invent of phylogenetic data (Study 3A), and how first inventing a diagram influences later interpretations of the standard notation (Study 3B). Lastly, I describe the prototype design and pilot test of an interactive diagram to scaffold biology students' understanding of this expert scientific notation. Insights from this dissertation inform the design of more pedagogically useful representations that might support students' developing fluency with expert scientific representations.
ERIC Educational Resources Information Center
Frankel, Lois; Brownstein, Beth; Soiffer, Neil
2017-01-01
This report describes the pilot conducted in the final phase of a project, Expanding Audio Access to Mathematics Expressions by Students With Visual Impairments via MathML, to provide easy-to-use tools for authoring and rendering secondary-school algebra-level math expressions in synthesized speech that is useful for students with blindness or low…
ERIC Educational Resources Information Center
Rodenborn, Leo V., Jr.
The project's purpose was to determine whether attention to the task during testing was a confounding variable in measures of visual perception ability. Samples of 30 perceptually handicapped (PH) and 30 normal subjects (N) were randomly selected from children so classified on the Frostig DTVP, providing they had IQ scores between 85 and 115 on…
Toward semantic-based retrieval of visual information: a model-based approach
NASA Astrophysics Data System (ADS)
Park, Youngchoon; Golshani, Forouzan; Panchanathan, Sethuraman
2002-07-01
This paper center around the problem of automated visual content classification. To enable classification based image or visual object retrieval, we propose a new image representation scheme called visual context descriptor (VCD) that is a multidimensional vector in which each element represents the frequency of a unique visual property of an image or a region. VCD utilizes the predetermined quality dimensions (i.e., types of features and quantization level) and semantic model templates mined in priori. Not only observed visual cues, but also contextually relevant visual features are proportionally incorporated in VCD. Contextual relevance of a visual cue to a semantic class is determined by using correlation analysis of ground truth samples. Such co-occurrence analysis of visual cues requires transformation of a real-valued visual feature vector (e.g., color histogram, Gabor texture, etc.,) into a discrete event (e.g., terms in text). Good-feature to track, rule of thirds, iterative k-means clustering and TSVQ are involved in transformation of feature vectors into unified symbolic representations called visual terms. Similarity-based visual cue frequency estimation is also proposed and used for ensuring the correctness of model learning and matching since sparseness of sample data causes the unstable results of frequency estimation of visual cues. The proposed method naturally allows integration of heterogeneous visual or temporal or spatial cues in a single classification or matching framework, and can be easily integrated into a semantic knowledge base such as thesaurus, and ontology. Robust semantic visual model template creation and object based image retrieval are demonstrated based on the proposed content description scheme.
NASA Technical Reports Server (NTRS)
Holmes, B. J.; Gall, P. D.; Croom, C. C.; Manuel, G. S.; Kelliher, W. C.
1986-01-01
The visualization of laminar to turbulent boundary layer transition plays an important role in flight and wind-tunnel aerodynamic testing of aircraft wing and body surfaces. Visualization can help provide a more complete understanding of both transition location as well as transition modes; without visualization, the transition process can be very difficult to understand. In the past, the most valuable transition visualization methods for flight applications included sublimating chemicals and oil flows. Each method has advantages and limitations. In particular, sublimating chemicals are impractical to use in subsonic applications much above 20,000 feet because of the greatly reduced rates of sublimation at lower temperatures (less than -4 degrees Farenheit). Both oil flow and sublimating chemicals have the disadvantage of providing only one good data point per flight. Thus, for many important flight conditions, transition visualization has not been readily available. This paper discusses a new method for visualizing transition in flight by the use of liquid crystals. The new method overcomes the limitations of past techniques, and provides transition visualization capability throughout almost the entire altitude and speed ranges of virtually all subsonic aircraft flight envelopes. The method also has wide applicability for supersonic transition visualization in flight and for general use in wind tunnel research over wide subsonic and supersonic speed ranges.
19 CFR 181.33 - Customs processing procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... under § 181.32 of this part, the port director shall determine whether the entry covering the good has... that any protest or any petition or request for reliquidation relating to the good has not been finally... or dutiability of the good is filed in the Court of International Trade, the port director shall...
How visualization layout relates to locus of control and other personality factors.
Ziemkiewicz, Caroline; Ottley, Alvitta; Crouser, R Jordan; Yauilla, Ashley Rye; Su, Sara L; Ribarsky, William; Chang, Remco
2013-07-01
Existing research suggests that individual personality differences are correlated with a user's speed and accuracy in solving problems with different types of complex visualization systems. We extend this research by isolating factors in personality traits as well as in the visualizations that could have contributed to the observed correlation. We focus on a personality trait known as "locus of control” (LOC), which represents a person's tendency to see themselves as controlled by or in control of external events. To isolate variables of the visualization design, we control extraneous factors such as color, interaction, and labeling. We conduct a user study with four visualizations that gradually shift from a list metaphor to a containment metaphor and compare the participants' speed, accuracy, and preference with their locus of control and other personality factors. Our findings demonstrate that there is indeed a correlation between the two: participants with an internal locus of control perform more poorly with visualizations that employ a containment metaphor, while those with an external locus of control perform well with such visualizations. These results provide evidence for the externalization theory of visualization. Finally, we propose applications of these findings to adaptive visual analytics and visualization evaluation.
The visual white matter: The application of diffusion MRI and fiber tractography to vision science
Rokem, Ariel; Takemura, Hiromasa; Bock, Andrew S.; Scherf, K. Suzanne; Behrmann, Marlene; Wandell, Brian A.; Fine, Ione; Bridge, Holly; Pestilli, Franco
2017-01-01
Visual neuroscience has traditionally focused much of its attention on understanding the response properties of single neurons or neuronal ensembles. The visual white matter and the long-range neuronal connections it supports are fundamental in establishing such neuronal response properties and visual function. This review article provides an introduction to measurements and methods to study the human visual white matter using diffusion MRI. These methods allow us to measure the microstructural and macrostructural properties of the white matter in living human individuals; they allow us to trace long-range connections between neurons in different parts of the visual system and to measure the biophysical properties of these connections. We also review a range of findings from recent studies on connections between different visual field maps, the effects of visual impairment on the white matter, and the properties underlying networks that process visual information supporting visual face recognition. Finally, we discuss a few promising directions for future studies. These include new methods for analysis of MRI data, open datasets that are becoming available to study brain connectivity and white matter properties, and open source software for the analysis of these data. PMID:28196374
Pupil size stability of the cubic phase mask solution for presbyopia
NASA Astrophysics Data System (ADS)
Almaguer, Citlalli; Acosta, Eva; Arines, Justo
2018-01-01
Presbyopia correction involves different types of studies such as lens design, clinical study, and the development of objective metrics, such as the visual Strehl ratio. Different contact lens designs have been proposed for presbyopia correction, but performance depends on pupil diameter. We will analyze the potential use of a nonsymmetrical element, a cubic phase mask (CPM) solution, to develop a contact or intraocular lens whose performance is nearly insensitive to changes in pupil diameter. We will show the through focus optical transfer function of the proposed element for different pupil diameters ranging from 3 to 7 mm. Additionally, we will show the images obtained through computation and experiment for a group of eye charts with different visual acuities. Our results show that a CPM shaped as 7.07 μm*(Z33-Z3-3)-0.9 μm Z20 is a good solution for a range of clear vision with a visual acuity of at least 0.1 logMar from 0.4 to 6 m for pupil diameters in the 3- to 7-mm range. Our results appear to be a good starting point for further development and study of this kind of CPM solution for presbyopia.
Loupe magnification for small incision cataract surgery--an alternative to microscope magnification?
Singh, S K; Winter, I; Hennig, A
2008-01-01
A Prospective randomized controlled study was conducted to compare outcome of Small Incision Cataract Surgery (SICS) using microscope or loupe magnification. Two hundred fifty one patient with mature cataract were randomly allocated to SICS-Fishhook Technique with either microscope (127 eyes) or loupe (124 eyes) magnification. Intra- and postoperative complications and immediate visual outcome were analyzed. Nearly two third (microscope 65% and magnifying loupe 62.9%) of all patients had good visual outcome on first postoperative day. Poor outcome (<6/60) was recorded in 8% (microscope group) and 7% (magnifying loupe group). Mean visual acuity with Snellen was 0.39 (SD 0.2) in microscope group and 0.38 (SD 0.2) in magnifying loupe group. Intra operative complications were comparable in both groups. Mean surgery time with loupe magnification was significantly shorter. Comparatively equivalent good surgical outcome was achieved with loupe as well as with microscope magnification. However performing SICS with loupe magnification is significantly faster. Small incision cataract surgery with loupe magnification is safe and effective procedure for cataract surgery so it can play a role in reducing cataract blindness in developing countries of the world.
Multi Agent Reward Analysis for Learning in Noisy Domains
NASA Technical Reports Server (NTRS)
Tumer, Kagan; Agogino, Adrian K.
2005-01-01
In many multi agent learning problems, it is difficult to determine, a priori, the agent reward structure that will lead to good performance. This problem is particularly pronounced in continuous, noisy domains ill-suited to simple table backup schemes commonly used in TD(lambda)/Q-learning. In this paper, we present a new reward evaluation method that allows the tradeoff between coordination among the agents and the difficulty of the learning problem each agent faces to be visualized. This method is independent of the learning algorithm and is only a function of the problem domain and the agents reward structure. We then use this reward efficiency visualization method to determine an effective reward without performing extensive simulations. We test this method in both a static and a dynamic multi-rover learning domain where the agents have continuous state spaces and where their actions are noisy (e.g., the agents movement decisions are not always carried out properly). Our results show that in the more difficult dynamic domain, the reward efficiency visualization method provides a two order of magnitude speedup in selecting a good reward. Most importantly it allows one to quickly create and verify rewards tailored to the observational limitations of the domain.
A high-speed photographic system for flow visualization in a steam turbine
NASA Technical Reports Server (NTRS)
Barna, G. J.
1973-01-01
A photographic system was designed to visualize the moisture flow in a steam turbine. Good performance of the system was verified using dry turbine mockups in which an aerosol spray simulated, in a rough way, the moisture flow in the turbine. Borescopes and fiber-optic light tubes were selected as the general instrumentation approach. High speed motion-picture photographs of the liquid flow over the stator blade surfaces were taken using stroboscopic lighting. Good visualization of the liquid flow was obtained. Still photographs of drops in flight were made using short duration flash sources. Drops with diameters as small as 30 micrometers (0.0012 in.) could be resolved. In addition, motion pictures of a spray of water simulating the spray off the rotor blades and shrouds were taken at normal framing rates. Specially constructed light tubes containing small tungsten-halogen lamps were used. Sixteen millimeter photography was used in all cases. Two potential problems resulting from the two-phase turbine flow (attenuation and scattering of light by the fog present and liquid accumulation on the borescope mirrors) were taken into account in the photographic system design but not evaluated experimentally.
Compact sensitive instrument for direct ultrasonic visualization of defects.
Bar-Cohen, Y; Ben-Joseph, B; Harnik, E
1978-12-01
A simple ultrasonic imaging cell based on the confocal combination of a plano-concave lens and a concave spherical mirror is described. When used in conjunction with a stroboscopic schlieren visualization system, it has the main attributes of a practical nondestructive testing instrument: it is compact, relatively inexpensive, and simple to operate; its sensitivity is fair, resolution and fidelity are good; it has a fairly large field of view and a test piece can be readily scanned. The scope of its applicability is described and discussed.
Treatments for dry age-related macular degeneration and Stargardt disease: a systematic review.
Waugh, Norman; Loveman, Emma; Colquitt, Jill; Royle, Pamela; Yeong, Jian Lee; Hoad, Geraldine; Lois, Noemi
2018-05-01
Age-related macular degeneration (AMD) is the leading cause of visual loss in older people. Advanced AMD takes two forms, neovascular (wet) and atrophic (dry). Stargardt disease (STGD) is the commonest form of inherited macular dystrophy. To carry out a systematic review of treatments for dry AMD and STGD, and to identify emerging treatments where future NIHR research might be commissioned. Systematic review. We searched MEDLINE, EMBASE, Web of Science and The Cochrane Library from 2005 to 13 July 2017 for reviews, journal articles and meeting abstracts. We looked for studies of interventions that aim to preserve or restore vision in people with dry AMD or STGD. The most important outcomes are those that matter to patients: visual acuity (VA), contrast sensitivity, reading speed, ability to drive, adverse effects of treatment, quality of life, progression of disease and patient preference. However, visual loss is a late event and intermediate predictors of future decline were accepted if there was good evidence that they are strong predictors of subsequent visual outcomes. These include changes detectable by investigation, but not necessarily noticed by people with AMD or STGD. ClinicalTrials.gov, the World Health Organization search portal and the UK Clinical Trials gateway were searched for ongoing and recently completed clinical trials. The titles and abstracts of 7948 articles were screened for inclusion. The full text of 398 articles were obtained for further screening and checking of references and 112 articles were included in the final report. Overall, there were disappointingly few good-quality studies (including of sufficient size and duration) reporting useful outcomes, particularly in STGD. However we did identify a number of promising research topics, including drug treatments, stem cells, new forms of laser treatment, and implantable intraocular lens telescopes. In many cases, research is already under way, funded by industry or governments. In AMD, the main limitation came from the poor quality of much of the evidence. Many studies used VA as their main outcome despite not having sufficient duration to observe changes. The evidence on treatments for STGD is sparse. Most studies tested interventions with no comparison group, were far too short term, and the quality of some studies was poor. We think that the topics on which the Health Technology Assessment (HTA) and Efficacy Mechanism and Evaluation (EME) programmes might consider commissioning primary research are in STGD, a HTA trial of fenretinide (ReVision Therapeutics, San Diego, CA, USA), a visual cycle inhibitor, and EME research into the value of lutein and zeaxanthin supplements, using short-term measures of retinal function. In AMD, we suggest trials of fenretinide and of a potent statin. There is epidemiological evidence from the USA that the drug, levodopa, used for treating Parkinson's disease, may reduce the incidence of AMD. We suggest that similar research should be carried out using the large general practice databases in the UK. Ideally, future research should be at earlier stages in both diseases, before vision is impaired, using sensitive measures of macular function. This may require early detection of AMD by screening. This study is registered as PROSPERO CRD42016038708. The National Institute for Health Research HTA programme.
Mackrous, I; Simoneau, M
2011-11-10
Following body rotation, optimal updating of the position of a memorized target is attained when retinal error is perceived and corrective saccade is performed. Thus, it appears that these processes may enable the calibration of the vestibular system by facilitating the sharing of information between both reference frames. Here, it is assessed whether having sensory information regarding body rotation in the target reference frame could enhance an individual's learning rate to predict the position of an earth-fixed target. During rotation, participants had to respond when they felt their body midline had crossed the position of the target and received knowledge of result. During practice blocks, for two groups, visual cues were displayed in the same reference frame of the target, whereas a third group relied on vestibular information (vestibular-only group) to predict the location of the target. Participants, unaware of the role of the visual cues (visual cues group), learned to predict the location of the target and spatial error decreased from 16.2 to 2.0°, reflecting a learning rate of 34.08 trials (determined from fitting a falling exponential model). In contrast, the group aware of the role of the visual cues (explicit visual cues group) showed a faster learning rate (i.e. 2.66 trials) but similar final spatial error 2.9°. For the vestibular-only group, similar accuracy was achieved (final spatial error of 2.3°), but their learning rate was much slower (i.e. 43.29 trials). Transferring to the Post-test (no visual cues and no knowledge of result) increased the spatial error of the explicit visual cues group (9.5°), but it did not change the performance of the vestibular group (1.2°). Overall, these results imply that cognition assists the brain in processing the sensory information within the target reference frame. Copyright © 2011 IBRO. Published by Elsevier Ltd. All rights reserved.
Chronic methadone use, poor bowel visualization and failed colonoscopy: A preliminary study
Verma, Siddharth; Fogel, Joshua; Beyda, David J; Bernstein, Brett; Notar-Francesco, Vincent; Mohanty, Smruti R
2012-01-01
AIM: To examine effects of chronic methadone usage on bowel visualization, preparation, and repeat colonoscopy. METHODS: In-patient colonoscopy reports from October, 2004 to May, 2009 for methadone dependent (MD) patients were retrospectively evaluated and compared to matched opioid naive controls (C). Strict criteria were applied to exclude patients with risk factors known to cause constipation or gastric dysmotility. Colonoscopy reports of all eligible patients were analyzed for degree of bowel visualization, assessment of bowel preparation (good, fair, or poor), and whether a repeat colonoscopy was required. Bowel visualization was scored on a 4 point scale based on multiple prior studies: excellent = 1, good = 2, fair = 3, or poor = 4. Analysis of variance (ANOVA) and Pearson χ2 test were used for data analyses. Subgroup analysis included correlation between methadone dose and colonoscopy outcomes. All variables significantly differing between MD and C groups were included in both univariate and multivariate logistic regression analyses. P values were two sided, and < 0.05 were considered statistically significant. RESULTS: After applying exclusionary criteria, a total of 178 MD patients and 115 C patients underwent a colonoscopy during the designated study period. A total of 67 colonoscopy reports for MD patients and 72 for C were included for data analysis. Age and gender matched controls were randomly selected from this population to serve as controls in a numerically comparable group. The average age for MD patients was 52.2 ± 9.2 years (range: 32-72 years) years compared to 54.6 ± 15.5 years (range: 20-81 years) for C (P = 0.27). Sixty nine percent of patients in MD and 65% in C group were males (P = 0.67). When evaluating colonoscopy reports for bowel visualization, MD patients had significantly greater percentage of solid stool (i.e., poor visualization) compared to C (40.3% vs 6.9%, P < 0.001). Poor bowel preparation (35.8% vs 9.7%, P < 0.001) and need for repeat colonoscopy (32.8% vs 12.5%, P = 0.004) were significantly higher in MD group compared to C, respectively. Under univariate analysis, factors significantly associated with MD group were presence of fecal particulate [odds ratio (OR), 3.89, 95% CI: 1.33-11.36, P = 0.01] and solid stool (OR, 13.5, 95% CI: 4.21-43.31, P < 0.001). Fair (OR, 3.82, 95% CI: 1.63-8.96, P = 0.002) and poor (OR, 8.10, 95% CI: 3.05-21.56, P < 0.001) assessment of bowel preparation were more likely to be associated with MD patients. Requirement for repeat colonoscopy was also significant higher in MD group (OR, 3.42, 95% CI: 1.44-8.13, P = 0.01). In the multivariate analyses, the only variable independently associated with MD group was presence of solid stool (OR, 7.77, 95% CI: 1.66-36.47, P = 0.01). Subgroup analysis demonstrated a general trend towards poorer bowel visualization with higher methadone dosage. ANOVA analysis demonstrated that mean methadone dose associated with presence of solid stool (poor visualization) was significantly higher compared to mean dosage for clean colon (excellent visualization, P = 0.02) or for those with liquid stool only (good visualization, P = 0.01). CONCLUSION: Methadone dependence is a risk factor for poor bowel visualization and leads to more repeat colonoscopies. More aggressive bowel preparation may be needed in MD patients. PMID:22969198
Sorkin, Nir; Showail, Mahmood; Einan-Lifshitz, Adi; Boutin, Tanguy; Borovik, Armand; Kreimei, Mohammad; Rosenblatt, Amir; Chan, Clara C; Rootman, David S
2018-06-01
To analyze the outcomes of Descemet membrane endothelial keratoplasty (DMEK) in eyes with previous Descemet stripping automated endothelial keratoplasty (DSAEK). This retrospective interventional case series included 26 eyes (26 patients) that underwent DMEK to replace a previous DSAEK graft with at least 6 months of follow-up. The outcome measures were indications for surgery, best spectacle-corrected visual acuity (BSCVA), endothelial cell density, rebubbling rate, rejection, and failure. Patient age was 71.9 ± 12.6 years. The average follow-up time after DMEK was 15.1 ± 10.6 months. Indications for DMEK were DSAEK graft failure (69%) and a DSAEK suboptimal visual outcome (31%). BSCVA of the entire cohort (n = 26) improved from 1.33 ± 0.78 logMAR preoperatively to 1.04 ± 0.78 and 1.06 ± 0.89 logMAR at 6 months postoperatively and at the last follow-up, respectively (P = 0.019 and P = 0.033). BSCVA among eyes without visual comorbidities (n = 13) improved from 0.84 ± 0.50 logMAR preoperatively to 0.55 ± 0.47 and 0.51 ± 0.49 logMAR at 6 months postoperatively and at final follow-up, respectively (P = 0.023 for both). Of these eyes, 84.6% had improvement in BSCVA at 6 months postoperatively and at last follow-up. In the subgroup of 8 eyes with DMEK for suboptimal visual outcomes after DSAEK, BSCVA improved from 0.81 ± 0.44 to 0.52 ± 0.35 logMAR at final follow-up (P = 0.024). When excluding eyes with visual comorbidities, BSCVA of this subgroup (n = 5) improved from 0.54 ± 0.32 to 0.36 ± 0.25 logMAR at final follow-up (P = 0.038). BSCVA of this subgroup at 6 months postoperatively was not significantly different from preoperative BSCVA, when including visual comorbidities (n = 8, 0.75 ± 0.60 logMAR, P = 0.79) and when excluding visual comorbidities (n = 5, 0.40 ± 0.28 logMAR, P = 0.621). Endothelial cell density decreased from 2753 ± 307 cells/mm to 1659 ± 655 cells/mm 6 months after surgery (39.7% loss, P = 0.005). Three eyes (11.5%) required rebubbling, and 5 eyes (19.2%) had secondary graft failure at 2 to 20 months. DMEK is effective for replacing previous DSAEK not only for graft failure but also for suboptimal visual outcomes.
Tools for 3D scientific visualization in computational aerodynamics at NASA Ames Research Center
NASA Technical Reports Server (NTRS)
Bancroft, Gordon; Plessel, Todd; Merritt, Fergus; Watson, Val
1989-01-01
Hardware, software, and techniques used by the Fluid Dynamics Division (NASA) for performing visualization of computational aerodynamics, which can be applied to the visualization of flow fields from computer simulations of fluid dynamics about the Space Shuttle, are discussed. Three visualization techniques applied, post-processing, tracking, and steering, are described, as well as the post-processing software packages used, PLOT3D, SURF (Surface Modeller), GAS (Graphical Animation System), and FAST (Flow Analysis software Toolkit). Using post-processing methods a flow simulation was executed on a supercomputer and, after the simulation was complete, the results were processed for viewing. It is shown that the high-resolution, high-performance three-dimensional workstation combined with specially developed display and animation software provides a good tool for analyzing flow field solutions obtained from supercomputers.
Final Report - Cloud-Based Management Platform for Distributed, Multi-Domain Networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chowdhury, Pulak; Mukherjee, Biswanath
2017-11-03
In this Department of Energy (DOE) Small Business Innovation Research (SBIR) Phase II project final report, Ennetix presents the development of a solution for end-to-end monitoring, analysis, and visualization of network performance for distributed networks. This solution benefits enterprises of all sizes, operators of distributed and federated networks, and service providers.
Logging slash flammability after five years
George R. Fahnestock; John H. Dieterich
1962-01-01
This paper reports the final phase of research that has determined the flammability of slash for nine species of northern Rocky Mountain conifers at three ages. Visual characteristics, rate of fire spread, and fire intensity for 5-year-old slash were studied by essentially the same methods as had been used previously on freshly cut and 1-year-old material. Final...
The Attentional Drift Diffusion Model of Simple Perceptual Decision-Making.
Tavares, Gabriela; Perona, Pietro; Rangel, Antonio
2017-01-01
Perceptual decisions requiring the comparison of spatially distributed stimuli that are fixated sequentially might be influenced by fluctuations in visual attention. We used two psychophysical tasks with human subjects to investigate the extent to which visual attention influences simple perceptual choices, and to test the extent to which the attentional Drift Diffusion Model (aDDM) provides a good computational description of how attention affects the underlying decision processes. We find evidence for sizable attentional choice biases and that the aDDM provides a reasonable quantitative description of the relationship between fluctuations in visual attention, choices and reaction times. We also find that exogenous manipulations of attention induce choice biases consistent with the predictions of the model.
Programming (Tips) for Physicists & Engineers
Ozcan, Erkcan
2018-02-19
Programming for today's physicists and engineers. Work environment: today's astroparticle, accelerator experiments and information industry rely on large collaborations. Need more than ever: code sharing/resuse, code building--framework integration, documentation and good visualization, working remotely, not reinventing the wheel.
Programming (Tips) for Physicists & Engineers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozcan, Erkcan
2010-07-13
Programming for today's physicists and engineers. Work environment: today's astroparticle, accelerator experiments and information industry rely on large collaborations. Need more than ever: code sharing/resuse, code building--framework integration, documentation and good visualization, working remotely, not reinventing the wheel.
21 CFR 58.206 - Final order on disqualification.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Final order on disqualification. 58.206 Section 58.206 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Disqualification of Testing Facilities § 58.206 Final...
21 CFR 58.206 - Final order on disqualification.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Final order on disqualification. 58.206 Section 58.206 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Disqualification of Testing Facilities § 58.206 Final...
Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro
2014-07-01
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.
Clavicular hook plate for grade-III acromioclavicular dislocation.
Steinbacher, Gilbert; Sallent, Andrea; Seijas, Roberto; Boffa, Juan Manuel; Espinosa, Wenceslao; Cugat, Ramón
2014-12-01
To review the outcomes of clavicular hook plate fixation for grade-III acromioclavicular (AC) dislocation in young athletes. Medical records of 14 male and 5 female athletes aged 18 to 49 (mean, 29) years who underwent fixation with a 3.5-mm-thick, 15-mm-long clavicular hook plate for acute grade-III AC dislocation were reviewed. The visual analogue score for pain and the Constant shoulder score were assessed. The mean follow-up was 4.2 years. The mean visual analogue score for pain was 1.8 (range, 1-3). The Constant shoulder score was excellent (≥ 90) in 14 patients and good (83-89) in 5 patients. All patients achieved range of motion equal to that of the contralateral side at week 5. Sports activities were resumed by month 6 at the latest. The clavicular hook plate for grade- III AC dislocation enables quick return to sports activities and achieves good-to-excellent functional outcome.
Smartphone serious games for vision and hearing assessment.
Dias, Pedro; Aguiar, Bruno; Sousa, Filipe; Sousa, Augusto
2015-01-01
Falls are the second leading cause of accidental injury deaths worldwide. In this paper, it is intended to define methodologies that permit the evaluation of two potential factors which might have an impact on fall risk, these are: visual and hearing loss. The aim of the work developed is not to replace clinic visits, but to offer the user the means to continue the tracking of his vision and hearing at home, during the long time intervals between clinical tests. Tests conducted in a sample of our target users indicate a good ability to measure vision and hearing using an android smartphone and the proposed methodologies. While some tests require further validation, promising results were achieved in the most common tests for vision and hearing, presenting a good correlation between the system's results when compared to the traditional tests (for distance visual acuity) and the data gathered from the users (for hearing tests).
High-frequency neural oscillations and visual processing deficits in schizophrenia
Tan, Heng-Ru May; Lana, Luiz; Uhlhaas, Peter J.
2013-01-01
Visual information is fundamental to how we understand our environment, make predictions, and interact with others. Recent research has underscored the importance of visuo-perceptual dysfunctions for cognitive deficits and pathophysiological processes in schizophrenia. In the current paper, we review evidence for the relevance of high frequency (beta/gamma) oscillations towards visuo-perceptual dysfunctions in schizophrenia. In the first part of the paper, we examine the relationship between beta/gamma band oscillations and visual processing during normal brain functioning. We then summarize EEG/MEG-studies which demonstrate reduced amplitude and synchrony of high-frequency activity during visual stimulation in schizophrenia. In the final part of the paper, we identify neurobiological correlates as well as offer perspectives for future research to stimulate further inquiry into the role of high-frequency oscillations in visual processing impairments in the disorder. PMID:24130535
Generalized information fusion and visualization using spatial voting and data modeling
NASA Astrophysics Data System (ADS)
Jaenisch, Holger M.; Handley, James W.
2013-05-01
We present a novel and innovative information fusion and visualization framework for multi-source intelligence (multiINT) data using Spatial Voting (SV) and Data Modeling. We describe how different sources of information can be converted into numerical form for further processing downstream, followed by a short description of how this information can be fused using the SV grid. As an illustrative example, we show the modeling of cyberspace as cyber layers for the purpose of tracking cyber personas. Finally we describe a path ahead for creating interactive agile networks through defender customized Cyber-cubes for network configuration and attack visualization.
SeeDB: Efficient Data-Driven Visualization Recommendations to Support Visual Analytics
Vartak, Manasi; Rahman, Sajjadur; Madden, Samuel; Parameswaran, Aditya; Polyzotis, Neoklis
2015-01-01
Data analysts often build visualizations as the first step in their analytical workflow. However, when working with high-dimensional datasets, identifying visualizations that show relevant or desired trends in data can be laborious. We propose SeeDB, a visualization recommendation engine to facilitate fast visual analysis: given a subset of data to be studied, SeeDB intelligently explores the space of visualizations, evaluates promising visualizations for trends, and recommends those it deems most “useful” or “interesting”. The two major obstacles in recommending interesting visualizations are (a) scale: evaluating a large number of candidate visualizations while responding within interactive time scales, and (b) utility: identifying an appropriate metric for assessing interestingness of visualizations. For the former, SeeDB introduces pruning optimizations to quickly identify high-utility visualizations and sharing optimizations to maximize sharing of computation across visualizations. For the latter, as a first step, we adopt a deviation-based metric for visualization utility, while indicating how we may be able to generalize it to other factors influencing utility. We implement SeeDB as a middleware layer that can run on top of any DBMS. Our experiments show that our framework can identify interesting visualizations with high accuracy. Our optimizations lead to multiple orders of magnitude speedup on relational row and column stores and provide recommendations at interactive time scales. Finally, we demonstrate via a user study the effectiveness of our deviation-based utility metric and the value of recommendations in supporting visual analytics. PMID:26779379
SeeDB: Efficient Data-Driven Visualization Recommendations to Support Visual Analytics.
Vartak, Manasi; Rahman, Sajjadur; Madden, Samuel; Parameswaran, Aditya; Polyzotis, Neoklis
2015-09-01
Data analysts often build visualizations as the first step in their analytical workflow. However, when working with high-dimensional datasets, identifying visualizations that show relevant or desired trends in data can be laborious. We propose SeeDB, a visualization recommendation engine to facilitate fast visual analysis: given a subset of data to be studied, SeeDB intelligently explores the space of visualizations, evaluates promising visualizations for trends, and recommends those it deems most "useful" or "interesting". The two major obstacles in recommending interesting visualizations are (a) scale : evaluating a large number of candidate visualizations while responding within interactive time scales, and (b) utility : identifying an appropriate metric for assessing interestingness of visualizations. For the former, SeeDB introduces pruning optimizations to quickly identify high-utility visualizations and sharing optimizations to maximize sharing of computation across visualizations. For the latter, as a first step, we adopt a deviation-based metric for visualization utility, while indicating how we may be able to generalize it to other factors influencing utility. We implement SeeDB as a middleware layer that can run on top of any DBMS. Our experiments show that our framework can identify interesting visualizations with high accuracy. Our optimizations lead to multiple orders of magnitude speedup on relational row and column stores and provide recommendations at interactive time scales. Finally, we demonstrate via a user study the effectiveness of our deviation-based utility metric and the value of recommendations in supporting visual analytics.
You’re a good structure, Charlie Brown: The distribution of narrative categories in comic strips
Cohn, Neil
2014-01-01
Cohn’s (2013) theory of “Visual Narrative Grammar” argues that sequential images take on categorical roles in a narrative structure, which organizes them into hierarchic constituents analogous to the organization of syntactic categories in sentences. This theory proposes that narrative categories, like syntactic categories, can be identified through diagnostic tests that reveal tendencies for their distribution throughout a sequence. This paper describes four experiments testing these diagnostics to provide support for the validity of these narrative categories. In Experiment 1, participants reconstructed unordered panels of a comic strip into an order that makes sense. Experiment 2 measured viewing times to panels in sequences where the order of panels was reversed. In Experiment 3 participants again reconstructed strips, but also deleted a panel from the sequence. Finally, in Experiment 4 participants identified where a panel had been deleted from a comic strip, and rated that strip’s coherence. Overall, categories had consistent distributional tendencies within experiments and complementary tendencies across experiments. These results point toward an interaction between categorical roles and a global narrative structure. PMID:24646175
Motor expertise and performance in spatial tasks: A meta-analysis.
Voyer, Daniel; Jansen, Petra
2017-08-01
The present study aimed to provide a summary of findings relevant to the influence of motor expertise on performance in spatial tasks and to examine potential moderators of this effect. Studies of relevance were those in which individuals involved in activities presumed to require motor expertise were compared to non-experts in such activities. A final set of 62 effect sizes from 33 samples was included in a multilevel meta-analysis. The results showed an overall advantage in favor of motor experts in spatial tasks (d=0.38). However, the magnitude of that effect was moderated by expert type (athlete, open skills/ball sports, runner/cyclist, gymnast/dancers, musicians), stimulus type (2D, blocks, bodies, others), test category (mental rotation, spatial perception, spatial visualization), specific test (Mental Rotations Test, generic mental rotation, disembedding, rod-and-frame test, other), and publication status. These findings are discussed in the context of embodied cognition and the potential role of activities requiring motor expertise in promoting good spatial performance. Copyright © 2017 Elsevier B.V. All rights reserved.
You're a good structure, Charlie Brown: the distribution of narrative categories in comic strips.
Cohn, Neil
2014-01-01
Cohn's (2013) theory of "Visual Narrative Grammar" argues that sequential images take on categorical roles in a narrative structure, which organizes them into hierarchic constituents analogous to the organization of syntactic categories in sentences. This theory proposes that narrative categories, like syntactic categories, can be identified through diagnostic tests that reveal tendencies for their distribution throughout a sequence. This paper describes four experiments testing these diagnostics to provide support for the validity of these narrative categories. In Experiment 1, participants reconstructed unordered panels of a comic strip into an order that makes sense. Experiment 2 measured viewing times to panels in sequences where the order of panels was reversed. In Experiment 3, participants again reconstructed strips but also deleted a panel from the sequence. Finally, in Experiment 4 participants identified where a panel had been deleted from a comic strip and rated that strip's coherence. Overall, categories had consistent distributional tendencies within experiments and complementary tendencies across experiments. These results point toward an interaction between categorical roles and a global narrative structure. © 2014 Cognitive Science Society, Inc.
Adaptive enhancement for nonuniform illumination images via nonlinear mapping
NASA Astrophysics Data System (ADS)
Wang, Yanfang; Huang, Qian; Hu, Jing
2017-09-01
Nonuniform illumination images suffer from degenerated details because of underexposure, overexposure, or a combination of both. To improve the visual quality of color images, underexposure regions should be lightened, whereas overexposure areas need to be dimmed properly. However, discriminating between underexposure and overexposure is troublesome. Compared with traditional methods that produce a fixed demarcation value throughout an image, the proposed demarcation changes as local luminance varies, thus is suitable for manipulating complicated illumination. Based on this locally adaptive demarcation, a nonlinear modification is applied to image luminance. Further, with the modified luminance, we propose a nonlinear process to reconstruct a luminance-enhanced color image. For every pixel, this nonlinear process takes the luminance change and the original chromaticity into account, thus trying to avoid exaggerated colors at dark areas and depressed colors at highly bright regions. Finally, to improve image contrast, a local and image-dependent exponential technique is designed and applied to the RGB channels of the obtained color image. Experimental results demonstrate that our method produces good contrast and vivid color for both nonuniform illumination images and images with normal illumination.
Chen, J Y C; Terrence, P I
2008-08-01
This study examined the concurrent performance of military gunnery, robotics control and communication tasks in a simulated environment. More specifically, the study investigated how aided target recognition (AiTR) capabilities (delivered either through tactile or tactile + visual cueing) for the gunnery task might benefit overall performance. Results showed that AiTR benefited not only the gunnery task, but also the concurrent robotics and communication tasks. The participants' spatial ability was found to be a good indicator of their gunnery and robotics task performance. However, when AiTR was available to assist their gunnery task, those participants of lower spatial ability were able to perform their robotics tasks as well as those of higher spatial ability. Finally, participants' workload assessment was significantly higher when they teleoperated (i.e. remotely operated) a robot and when their gunnery task was unassisted. These results will further understanding of multitasking performance in military tasking environments. These results will also facilitate the implementation of robots in military settings and will provide useful data to military system designs.
Real-time EEG-based detection of fatigue driving danger for accident prediction.
Wang, Hong; Zhang, Chi; Shi, Tianwei; Wang, Fuwang; Ma, Shujun
2015-03-01
This paper proposes a real-time electroencephalogram (EEG)-based detection method of the potential danger during fatigue driving. To determine driver fatigue in real time, wavelet entropy with a sliding window and pulse coupled neural network (PCNN) were used to process the EEG signals in the visual area (the main information input route). To detect the fatigue danger, the neural mechanism of driver fatigue was analyzed. The functional brain networks were employed to track the fatigue impact on processing capacity of brain. The results show the overall functional connectivity of the subjects is weakened after long time driving tasks. The regularity is summarized as the fatigue convergence phenomenon. Based on the fatigue convergence phenomenon, we combined both the input and global synchronizations of brain together to calculate the residual amount of the information processing capacity of brain to obtain the dangerous points in real time. Finally, the danger detection system of the driver fatigue based on the neural mechanism was validated using accident EEG. The time distributions of the output danger points of the system have a good agreement with those of the real accident points.
Analysis, Simulation and Prediction of Cosmetic Defects on Automotive External Panel
NASA Astrophysics Data System (ADS)
Le Port, A.; Thuillier, S.; Borot, C.; Charbonneaux, J.
2011-08-01
The first feeling of quality for a vehicle is linked to its perfect appearance. This has a major impact on the reputation of a car manufacturer. Cosmetic defects are thus more and more taken into account in the process design. Qualifying a part as good or bad from the cosmetic point of view is mainly subjective: the part aspect is considered acceptable if no defect is visible on the vehicle by the final customer. Cosmetic defects that appear during sheet metal forming are checked by visual inspection in light inspection rooms, stoning, or with optical or mechanical sensors or feelers. A lack of cosmetic defect prediction before part production leads to the need for corrective actions, production delays and generates additional costs. This paper first explores the objective description of what cosmetic defects are on a stamped part and where they come from. It then investigates the capability of software to predict these defects, and suggests the use of a cosmetic defects analysis tool developed within PAM-STAMP 2G for its qualitative and quantitative prediction.
NASA Astrophysics Data System (ADS)
Militello, F.; Farley, T.; Mukhi, K.; Walkden, N.; Omotani, J. T.
2018-05-01
A statistical framework was introduced in Militello and Omotani [Nucl. Fusion 56, 104004 (2016)] to correlate the dynamics and statistics of L-mode and inter-ELM plasma filaments with the radial profiles of thermodynamic quantities they generate in the Scrape Off Layer. This paper extends the framework to cases in which the filaments are emitted from the separatrix at different toroidal positions and with a finite toroidal velocity. It is found that the toroidal velocity does not affect the profiles, while the toroidal distribution of filament emission renormalises the waiting time between two events. Experimental data collected by visual camera imaging are used to evaluate the statistics of the fluctuations, to inform the choice of the probability distribution functions used in the application of the framework. It is found that the toroidal separation of the filaments is exponentially distributed, thus suggesting the lack of a toroidal modal structure. Finally, using these measurements, the framework is applied to an experimental case and good agreement is found.
Operations dashboard: comparative study
NASA Astrophysics Data System (ADS)
Ramly, Noor Nashriq; Ismail, Ahmad Zuhairi; Aziz, Mohd Haris; Ahmad, Nurul Haszeli
2011-10-01
In this present days and age, there are increasing needs for companies to monitor application and infrastructure health. Apart from having proactive measures to secure their application and infrastructure, many see monitoring dashboards as crucial investment in disaster preparedness. As companies struggle to find the best solution to cater for their needs and interest for monitoring their application and infrastructure's health, this paper summarizes the studies made on several known off-the-shelf operations dashboard and in-house developed dashboard. A few criteria of good dashboard are collected from previous studies carried out by several researchers and rank them according to importance and business needs. The finalized criteria that will be discussed in later sections are data visualization, performance indicator, dashboard personalization, audit capability and alert/ notification. Comparative studies between several popular dashboards were then carried out to determine whether they met these criteria that we derived from the first exercise. The findings hopefully can be used to educate and provide an overview of selecting the best IT application and infrastructure operations dashboard that suit business needs, thus become the main contribution of this paper.
An empirical investigation of the visual rightness theory of picture perception.
Locher, Paul J
2003-10-01
This research subjected the visual rightness theory of picture perception to experimental scrutiny. It investigated the ability of adults untrained in the visual arts to discriminate between reproductions of original abstract and representational paintings by renowned artists from two experimentally manipulated less well-organized versions of each art stimulus. Perturbed stimuli contained either minor or major disruptions in the originals' principal structural networks. It was found that participants were significantly more successful in discriminating between originals and their highly altered, but not slightly altered, perturbation than expected by chance. Accuracy of detection was found to be a function of style of painting and a viewer's way of thinking about a work as determined from their verbal reactions to it. Specifically, hit rates for originals were highest for abstract works when participants focused on their compositional style and form and highest for representational works when their content and realism were the focus of attention. Findings support the view that visually right (i.e., "good") compositions have efficient structural organizations that are visually salient to viewers who lack formal training in the visual arts.
Binocular visual training to promote recovery from monocular deprivation.
Murphy, Kathryn M; Roumeliotis, Grayson; Williams, Kate; Beston, Brett R; Jones, David G
2015-01-08
Abnormal early visual experience often leads to poor vision, a condition called amblyopia. Two recent approaches to treating amblyopia include binocular therapies and intensive visual training. These reflect the emerging view that amblyopia is a binocular deficit caused by increased neural noise and poor signal-in-noise integration. Most perceptual learning studies have used monocular training; however, a recent study has shown that binocular training is effective for improving acuity in adult human amblyopes. We used an animal model of amblyopia, based on monocular deprivation, to compare the effect of binocular training either during or after the critical period for ocular dominance plasticity (early binocular training vs. late binocular training). We used a high-contrast, orientation-in-noise stimulus to drive the visual cortex because neurophysiological findings suggest that binocular training may allow the nondeprived eye to teach the deprived eye's circuits to function. We found that both early and late binocular training promoted good visual recovery. Surprisingly, we found that monocular deprivation caused a permanent deficit in the vision of both eyes, which became evident only as a sleeper effect following many weeks of visual training. © 2015 ARVO.
Temple, S E; Manietta, D; Collin, S P
2013-05-03
Archerfish forage by shooting jets of water at insects above the water's surface. The challenge of detecting small prey items against a complex background suggests that they have good visual acuity, but to date this has never been tested, despite archerfish becoming an increasingly important model species for vertebrate vision. We used a modified Landolt C test to measure visual acuity behaviourally, and compared the results to their predicted minimum separable angle based on both photoreceptor and ganglion cell spacing in the retina. Both measures yielded similar estimates of visual acuity; between 3.23 and 3.57 cycles per degree (0.155-0.140° of visual arc). Such a close match between behavioural and anatomical estimates of visual acuity in fishes is unusual and may be due to our use of an ecologically relevant task that measured the resolving power of the part of the retina that has the highest photoreceptor density and that is used in aligning their spitting angle with potential targets. Copyright © 2013 Elsevier Ltd. All rights reserved.
Orssaud, C
2014-06-01
Amblyopia is a developmental disorder of the entire visual system, including the extra-striate cortex. It manifests mainly by impaired visual acuity in the amblyopic eye. However, other abnormalities of visual function can be observed, such as decreased contrast sensitivity and stereoscopic vision, and some abnormalities can be found in the "good" eye. Amblyopia occurs during the critical period of brain development. It may be due to organic pathology of the visual pathways, visual deprivation or functional abnormalities, mainly anisometropia or strabismus. The diagnosis of amblyopia must be confirmed prior to treatment. Confirmation is based on cycloplegic refraction, visual acuity measurement and orthoptic assessment. However, screening for amblyopia and associated risk factors permits earlier diagnosis and treatment. The younger the child, the more effective the treatment, and it can only be achieved during the critical period. It requires parental cooperation in order to be effective and is based on occlusion or penalization of the healthy eye. The amblyopic eye may then develop better vision. Maintenance therapy must be performed until the end of the critical period to avoid recurrence. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Acoustic Signature from Flames as a Combustion Diagnostic Tool
1983-11-01
empirical visual flame length had to be input to the computer for the inversion method to give good results. That is, if the experiment cnd inversion...method were asked to yield the flame length , poor results were obtained. Since this wa3 part of the information sought for practical application of the...to small experimental uncertainty. The method gave reasonably good results for the open flame but substantial input (the flame length ) had to be