NASA Astrophysics Data System (ADS)
Mohamed, Omar Ahmed; Hasan Masood, Syed; Lal Bhowmik, Jahar
2018-02-01
In the additive manufacturing (AM) market, the question is raised by industry and AM users on how reproducible and repeatable the fused deposition modeling (FDM) process is in providing good dimensional accuracy. This paper aims to investigate and evaluate the repeatability and reproducibility of the FDM process through a systematic approach to answer this frequently asked question. A case study based on the statistical gage repeatability and reproducibility (gage R&R) technique is proposed to investigate the dimensional variations in the printed parts of the FDM process. After running the simulation and analysis of the data, the FDM process capability is evaluated, which would help the industry for better understanding the performance of FDM technology.
Dresler, Maria Magdalena; Kociszewski, Jacek; Pędraszewski, Piotr; Trzeciak, Agnieszka; Surkont, Grzegorz
2017-01-01
Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. PMID:28856017
Sonoelastographic Features of the Patellar Ligament in Clinically Normal Dogs.
Piccionello, Angela P; Serrani, Daniele; Busoni, Valeria; Salvaggio, Alberto; Bonazzi, Mattia; Bergamino, Chiara; Volta, Antonella
2018-06-11
This article describes the sonoelastographic features of the patellar ligament of sound dogs and tests feasibility, reproducibility and repeatability. Clinically healthy medium-to-large breed dogs were enrolled. Sonoelastographic images of the patellar ligaments were obtained in lateral recumbency with the stifle flexed by an experienced operator and by a senior veterinary student. The elasticity colour map included red (soft), green (intermediate) and blue (hard). Tissue elasticity was measured by calculating the percentage of softness with dedicated software. Categorical, qualitative data analysis was performed using a weighted kappa statistic for repeatability and reproducibility. A categorical qualitative assessment was performed based on a grading scale of 1 to 5 (soft, mostly soft, intermediate, mostly hard and hard). Fourteen clinically normal dogs were considered. A total of 28 patellar ligaments were examined. Overall, 25 of the patellar ligaments were graded as soft or mostly soft and the remaining 3 as intermediate. Repeatability was 86.2%, with a weighted kappa of 0.64 (good), for the well-trained sonographer and 83.3%, with a weighted kappa of 0.53 (moderate), for the senior student. Reproducibility was 86.2%, with a weighed kappa of 0.65 (good). Sonoelastography of the canine patellar ligament is a feasible and reproducible technique. Patellar ligaments in clinically normal dogs showed highly elastic biomechanical properties. Schattauer GmbH Stuttgart.
Xu, Zhe; Peng, Mei; Jiang, Jun; Yang, Chun; Zhu, Weigen; Lu, Fan; Shen, Meixiao
2016-02-01
To measure the repeatability and reproducibility of Pentacam HR system thickness maps for the entire cornea in normal, post-laser in situ keratomileusis (post-LASIK), and keratoconus (KC) eyes. Reliability study. Sixty normal subjects (60 eyes), 30 post-LASIK subjects (60 eyes), and 14 KC patients (27 eyes) were imaged with the Pentacam HR system by 2 well-trained operators. For pachymetry the cornea was divided into 4 zones: a central zone (2-mm diameter) and concentric pericentral zone (2-5 mm), transitional zone (5-7 mm), and peripheral zone (7-10 mm). The 3 concentric zones were subdivided into 8 sectors. Intraobserver repeatability and interobserver reproducibility of entire corneal thickness maps were tested by the repeatability and reproducibility coefficients, intraclass correlation coefficients, coefficient of variation, and 95% limits of agreement. From central to peripheral zones, the precision of corneal thickness measurements became gradually smaller. Central zone repeatability and reproducibility were the best in the normal, post-LASIK, and KC groups. The peripheral superior sectors showed poorer repeatability and reproducibility for all subjects. The intraobserver repeatability and interobserver reproducibility for all zones were ≤19.3 μm, ≤22.1 μm, and ≤20.7 μm, in the normal, post-LASIK, and KC groups, respectively. The intraobserver and interobserver coefficients of variation for all zones were ≤1.3%, ≤1.6%, and ≤1.6% for all 3 groups. Pentacam HR system pachymetry of the entire cornea provided good precision in normal, post-LASIK, and KC corneas. Thickness measurements in the peripheral cornea should be interpreted with caution in abnormal corneas after surgery or with diseases. Copyright © 2016 Elsevier Inc. All rights reserved.
Huang, Jinhai; Liao, Na; Savini, Giacomo; Li, Yuanguang; Bao, Fangjun; Yu, Ye; Yu, Ayong; Wang, Qinmei
2015-02-01
To determine the repeatability and reproducibility of measurements of central corneal thickness (CCT) using optical low-coherence reflectometry (Lenstar LS900; Haag Streit) in normal eyes and post-femtosecond laser in situ keratomileusis (post-FS-LASIK) eyes and evaluate their agreement with ultrasound (US) pachymetry. CCT was measured using Lenstar and US pachymetry sequentially in normal and post-FS-LASIK eyes by 2 experienced observers. Intraoperator repeatability and interoperator reproducibility were assessed by within-subject standard deviation, test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient. Paired t-tests and Bland-Altman plots were used for analyzing agreement between the 2 devices. In this study, 55 healthy subjects and 50 post-FS-LASIK patients were recruited. Test-retest repeatability of Lenstar was within 10 μm, CoV was less than 1.0%, and intraclass correlation coefficient was more than 0.9 in both normal and post-FS-LASIK groups. Mean difference between these methods was 1.4 ± 4.2 μm and -1.7 ± 5.4 μm, respectively. Moreover, measurements of CCT showed narrow 95% limits of agreement (range, normal group: -6.8 and 9.6 μm; post-FS-LASIK group: -12.4 and 8.9 μm), which implied good agreement. Measurements of CCT using Lenstar showed excellent intraoperator repeatability and interoperator reproducibility both in normal eyes and post-FS-LASIK eyes. Measurements of CCT using Lenstar and US pachymetry showed good agreement and both can be used interchangeably.
Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer
Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure
2015-01-01
Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375
Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.
Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure
2015-01-01
Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.
Jadhav, Sachin; Sattar, Naveed; Petrie, John R; Cobbe, Stuart M; Ferrell, William R
2007-09-01
Interrogation of peripheral vascular function is increasingly recognized as a noninvasive surrogate marker for coronary vascular function and carries with it important prognostic information regarding future cardiovascular risk. Laser Doppler imaging (LDI) is a completely noninvasive method for looking at peripheral microvascular function. We sought to look at reproducibility and repeatability of LDI-derived assessment of peripheral microvascular function between arms and 8 weeks apart. We used LDI in conjunction with iontophoretic application of ACh and SNP to look at endothelium-dependent and -independent microvascular function, respectively, in a mixture of women with cardiac syndrome X and healthy volunteers. We looked at variation between arms (n = 40) and variation at 8 weeks apart (n = 22). When measurements were corrected for skin resistance, there was nonsignificant variation between arms for ACh (2.7%) and SNP (3.8%) and nonsignificant temporal variation for ACh (3.5%) and SNP (4.7%). Construction of Bland-Altman plots reinforce that measurements have good repeatability. Elimination of the baseline perfusion response had deleterious effects on repeatability. LDI can be used to assess peripheral vascular response with good repeatability as long as measurements are corrected for skin resistance, which affects drug delivery. This has important implications for the future use of LDI.
Measurement system analysis of viscometers used for drilling mud characterization
NASA Astrophysics Data System (ADS)
Mat-Shayuti, M. S.; Adzhar, S. N.
2017-07-01
Viscometers in the Faculty of Chemical Engineering, University Teknologi MARA, are subject to heavy utilization from the members of the faculty. Due to doubts surrounding their result integrity and maintenance management, Measurement System Analysis was executed. 5 samples of drilling muds with varied barite content from 5 - 25 weight% were prepared and their rheological properties determined in 3 trials by 3 operators using the viscometers. Gage Linearity and Bias Study were performed using Minitab software and the result shows high biases in the range of 19.2% to 38.7%, with non-linear trend along the span of measurements. Gage Repeatability & Reproducibility (Nested) analysis later produces Percent Repeatability & Reproducibility more than 7.7% and Percent Tolerance above 30%. Lastly, good and marginal Distinct Categories output are seen among the results. Despite acceptable performance of the measurement system in Distinct Categories, the poor results in accuracy, linearity, and Percent Repeatability & Reproducibility render the gage generally not capable. Improvement to the measurement system is imminent.
Huang, Jinhai; Savini, Giacomo; Wu, Fan; Yu, Xinxin; Yang, Jing; Yu, Ayong; Yu, Ye; Wang, Qinmei
2015-10-01
To assess the precision of ocular biometry with a new noncontact optical low-coherence interferometer (Aladdin) in healthy subjects and patients with cataracts. Eye Hospital of Wenzhou Medical University, Wenzhou, China. Observational cross-sectional study. Eyes from healthy subjects and eyes from patients with cataracts were examined with the new interferometer. Axial length (AL), anterior chamber depth (ACD), keratometry (K), and white-to-white (WTW) values were measured by 2 operators. The test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability. Different-operator comparison was analyzed with paired t tests and Bland-Altman plots to assess interoperator reproducibility. Ninety-eight people were enrolled for this study, of which 52 eyes were from healthy subjects and 46 eyes were from patients with cataracts. The AL was the most repeatable and reproducible parameter. The ACD, K values, and WTW measurements were highly repeatable in healthy subjects with CoV less than 0.89% and ICC more than 0.94. However, in patients with cataracts, high repeatability could only be observed for AL, ACD, and K values, whereas WTW measurement had test-retest repeatability of 0.80 mm and an ICC of 0.795. Bland-Altman analysis also showed good agreement between the 2 operators for ocular component measurements, except that the WTW in patients with cataracts had wider 95% limits of agreement (range -0.88 to 0.95 mm). The new biometer showed excellent intraoperator repeatability and interoperator reproducibility for AL, ACD, and K values measurements in both groups. The precision of WTW measurements was lower in patients with cataracts. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
An electronic nose for reliable measurement and correct classification of beverages.
Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A
2011-01-01
This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results.
An Electronic Nose for Reliable Measurement and Correct Classification of Beverages
Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A.
2011-01-01
This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results. PMID:22163964
Measurement of elasticity and transepidermal water loss rate of burn scars with the Dermalab(®).
Anthonissen, Mieke; Daly, Daniel; Fieuws, Steffen; Massagé, Patrick; Van Brussel, Michel; Vranckx, Jan; Van den Kerckhove, Eric
2013-05-01
This cross-sectional study investigated the reproducibility of repeated elasticity and transepidermal water loss (TEWL) measurements with the DermaLab(®) on 32 active burn scars and healthy skin. Intra- and inter-observer reproducibility was examined by means of intra-class correlation coefficients (ICC) and standard error of measurements (SEM). Results showed good ICC values and rather high SEM values for inter- and intra-observer reproducibility of elasticity measurements. For TEWL measurements, ICC values were good and SEM values were high for inter- and intra-observer reproducibility. There was a significant difference between the estimated mean elasticity values of normal skin and grafted scars and between normal skin and spontaneously healed scars (p≤0.003). For the estimated mean TEWL values, there was a significant difference between normal skin and spontaneously healed scars (p=0.036). A significant negative relation was reported between mean TEWL and time after burn (p=0.008). In clinical trials it is necessary to interpret patient-specific changes in elasticity and TEWL with caution, since the SEMs of both modes are rather high. We therefore recommend the use of a mean of repeated measurements of elasticity and TEWL to decrease the SEM. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.
Fakhri, Georges El
2011-01-01
82Rb cardiac PET allows the assessment of myocardial perfusion using a column generator in clinics that lack a cyclotron. We and others have previously shown that quantitation of myocardial blood flow (MBF) and coronary flow reserve (CFR) is feasible using dynamic 82Rb PET and factor and compartment analyses. The aim of the present work was to determine the intra- and inter-observer variability of MBF estimation using 82Rb PET as well as the reproducibility of our generalized factor + compartment analyses methodology to estimate MBF and assess its accuracy by comparing, in the same subjects, 82Rb estimates of MBF to those obtained using 13N-ammonia. Methods Twenty-two subjects were included in the reproducibility and twenty subjects in the validation study. Patients were injected with 60±5mCi of 82Rb and imaged dynamically for 6 minutes at rest and during dipyridamole stress Left and right ventricular (LV+RV) time-activity curves were estimated by GFADS and used as input to a 2-compartment kinetic analysis that estimates parametric maps of myocardial tissue extraction (K1) and egress (k2), as well as LV+RV contributions (fv,rv). Results Our results show excellent reproducibility of the quantitative dynamic approach itself with coefficients of repeatability of 1.7% for estimation of MBF at rest, 1.4% for MBF at peak stress and 2.8% for CFR estimation. The inter-observer reproducibility between the four observers that participated in this study was also very good with correlation coefficients greater than 0.87 between any two given observers when estimating coronary flow reserve. The reproducibility of MBF in repeated 82Rb studies was good at rest and excellent at peak stress (r2=0.835). Furthermore, the slope of the correlation line was very close to 1 when estimating stress MBF and CFR in repeated 82Rb studies. The correlation between myocardial flow estimates obtained at rest and during peak stress in 82Rb and 13N-ammonia studies was very good at rest (r2=0.843) and stress (r2=0.761). The Bland-Altman plots show no significant presence of proportional error at rest or stress, nor a dependence of the variations on the amplitude of the myocardial blood flow at rest or stress. A small systematic overestimation of 13N-ammonia MBF was observed with 82Rb at rest (0.129 ml/g/min) and the opposite, i.e., underestimation, at stress (0.22 ml/g/min). Conclusions Our results show that absolute quantitation of myocardial bloof flow is reproducible and accurate with 82Rb dynamic cardiac PET as compared to 13N-ammonia. The reproducibility of the quantitation approach itself was very good as well as inter-observer reproducibility. PMID:19525467
Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske
2014-01-01
To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.
Repeatability and Reproducibility of Virtual Subjective Refraction.
Perches, Sara; Collados, M Victoria; Ares, Jorge
2016-10-01
To establish the repeatability and reproducibility of a virtual refraction process using simulated retinal images. With simulation software, aberrated images corresponding with each step of the refraction process were calculated following the typical protocol of conventional subjective refraction. Fifty external examiners judged simulated retinal images until the best sphero-cylindrical refraction and the best visual acuity were achieved starting from the aberrometry data of three patients. Data analyses were performed to assess repeatability and reproducibility of the virtual refraction as a function of pupil size and aberrometric profile of different patients. SD values achieved in three components of refraction (M, J0, and J45) are lower than 0.25D in repeatability analysis. Regarding reproducibility, we found SD values lower than 0.25D in the most cases. When the results of virtual refraction with different pupil diameters (4 and 6 mm) were compared, the mean of differences (MoD) obtained were not clinically significant (less than 0.25D). Only one of the aberrometry profiles with high uncorrected astigmatism shows poor results for the M component in reproducibility and pupil size dependence analysis. In all cases, vision achieved was better than 0 logMAR. A comparison between the compensation obtained with virtual and conventional subjective refraction was made as an example of this application, showing good quality retinal images in both processes. The present study shows that virtual refraction has similar levels of precision as conventional subjective refraction. Moreover, virtual refraction has also shown that when high low order astigmatism is present, the refraction result is less precise and highly dependent on pupil size.
Cutajar, Marica; Thomas, David L; Hales, Patrick W; Banks, T; Clark, Christopher A; Gordon, Isky
2014-06-01
To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min(-1) [100 ml tissue](-1), and using DCE MRI was 287 ± 70 ml min(-1) [100 ml tissue](-1). The group coefficient of variation (CVg) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CVgs of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. Reliable non-invasive monitoring of renal blood flow is currently clinically unavailable. Renal arterial spin labelling MRI is robust and repeatable. Renal dynamic contrast-enhanced MRI is robust and repeatable. ASL blood flow values are similar to those obtained using DCE-MRI.
General radiographic attributes of optically stimulated luminescence dosimeters: A basic insight
NASA Astrophysics Data System (ADS)
Musa, Y.; Hashim, S.; Ghoshal, S. K.; Bradley, D. A.; Ahmad, N. E.; Karim, M. K. A.; Hashim, A.; Kadir, A. B. A.
2018-06-01
We report the ubiquitous radiographic characteristics of optically stimulated luminescence dosimeters (OSLD) so called nanoDot OSLDs (Landauer Inc., Glendwood, IL). The X-ray irradiations were performed in free air ambiance to inspect the repeatability, the reproducibility, the signal depletion, the element correction factors (ECFs), the dose response and the energy dependence. Repeatability of multiple readouts after single irradiation to 10 mGy revealed a coefficient of variation below 3%, while the reproducibility in repeated irradiation-readout-annealing cycles was above 2%. The OSL signal depletion for three nanoDots with simultaneous irradiation to 20 mGy and sequential readouts of 25 times displayed a consistent signal reduction ≈0.5% per readout with R2 values over 0.98. ECFs for individual OSLDs were varied from 0.97 to 1.03. In the entire dose range under 80 kV, a good linearity with an R2 exceeding 0.99 was achieved. Besides, the percentage difference between OSLD and ion-chamber dose was less than 5%, which was superior to TLD. The X-ray photon irradiated energy response factors (between 0.76 and 1.12) in the range of 40-150 kV (26.1-61.2 keV) exhibited significant energy dependence. Indeed, the nanoDot OSLDs disclosed good repeatability, reproducibility and linearity. The OSLDs measured doses were closer to ion-chamber doses than that of TLD. It can be further improved up to ≈3% by applying the individual dosimeter ECF. On top, the energy dependent uncertainties can be minimized using the energy correction factors. It is established that the studied nanoDot OSLDs are prospective for measuring entrance dose in general radiographic practices.
Xu, Zhe; Chen, Sisi; Yang, Chun; Huang, Shenghai; Shen, Meixiao; Wang, Yuanyuan
2018-01-01
To investigate the repeatability and reproducibility of mapping the entire corneal thickness using spectral domain optical coherence tomography (SD-OCT). Thirty normal eyes, 30 post-laser in situ keratomileusis (LASIK) surgery eyes, and 30 keratoconus eyes were analyzed. A custom-built long scan depth SD-OCT device was used to obtain entire corneal images. Ten-millimeter-diameter corneal thickness maps were generated by an automated segmentation algorithm. Intraclass correlation coefficients of repeatability (ICC1) and reproducibility (ICC2), and coefficients of repeatability (CoR1) and reproducibility (CoR2), were calculated to quantify the precision and accuracy of corneal pachymetry measurements using the Bland-Altman method. For SD-OCT measurements in healthy subjects, CoR1 and CoR2 were less than 5.00 and 5.53 μm. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in LASIK patients, CoR1 and CoR2 were less than 5.09 and 5.34 μm. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in keratoconus patients, CoR1 and CoR2 were less than 11.57 and 10.92 μm. ICC1 and ICC2 were more than 0.995 and 0.996. The measurements of corneal pachymetric mapping by long scan depth SD-OCT can be assessed over the entire corneal area with good repeatability and reproducibility. © 2017 S. Karger AG, Basel.
Reliability of Corneal Dynamic Scheimpflug Analyser Measurements in Virgin and Post-PRK Eyes
Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske
2014-01-01
Purpose To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Methods Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. Results The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05). Conclusions CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter. PMID:25302580
Inter-laboratory validation of bioaccessibility testing for metals.
Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R
2014-10-01
Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.
Measurement properties of continuous text reading performance tests.
Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B
2014-11-01
Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for reproducibility and repeatability studies. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.
Van den Kerckhove, Eric; Fieuws, Steffen; Massagé, Patrick; Hierner, Robert; Boeckx, Willy; Deleuze, Jean-Paul; Laperre, Jan; Anthonissen, Mieke
2007-08-01
This study investigated the reproducibility of repeated measurements with the Kikuhime pressure sensor under two different types of pressure garments used in the treatment and prevention of scars after burns. Also efficiency of garments was assessed in clinical circumstances by assessing pressure loss and residual pressure after 1 month. Intra- and inter-observer reproducibility and repeated measurements with 1-month time lapse were examined on 55 sites in 26 subjects by means of intra-class correlation coefficients and standard error of measurements. Results showed good to excellent ICC and low SEMs in the two conditions. There was a significant difference in pressure after 1 month between elastic tricot and weft knit garments, although evolution of pressure loss after 1 month was similar. Concerning different locations, there was a significant difference in pressure loss after 1 month between gloves and sleeves with the largest pressure loss for sleeves. Considering these results we concluded that the Kikuhime pressure sensor provides valid and reliable information and can be used in comparative clinical trials to evaluate pressure garments used in burn scar treatment. Secondly, elastic tricot garments in our study tended to have higher clinical pressures but both types of garments had similar pressure loss over time.
López-Miguel, Alberto; Martínez-Almeida, Loreto; González-García, María J; Coco-Martín, María B; Sobrado-Calvo, Paloma; Maldonado, Miguel J
2013-02-01
To assess the intrasession and intersession precision of ocular, corneal, and internal higher-order aberrations (HOAs) measured using an integrated topographer and Hartmann-Shack wavefront sensor (Topcon KR-1W) in refractive surgery candidates. IOBA-Eye Institute, Valladolid, Spain. Evaluation of diagnostic technology. To analyze intrasession repeatability, 1 experienced examiner measured eyes 9 times successively. To study intersession reproducibility, the same clinician obtained measurements from another set of eyes in 2 consecutive sessions 1 week apart. Ocular, corneal, and internal HOAs were obtained. Coma and spherical aberrations, 3rd- and 4th-order aberrations, and total HOAs were calculated for a 6.0 mm pupil diameter. For intrasession repeatability (75 eyes), excellent intraclass correlation coefficients (ICCs) were obtained (ICC >0.87), except for internal primary coma (ICC = 0.75) and 3rd-order (ICC = 0.72) HOAs. Repeatability precision (1.96 × S(w)) values ranged from 0.03 μm (corneal primary spherical) to 0.08 μm (ocular primary coma). For intersession reproducibility (50 eyes), ICCs were good (>0.8) for ocular primary spherical, 3rd-order, and total higher-order aberrations; reproducibility precision values ranged from 0.06 μm (corneal primary spherical) to 0.21 μm (internal 3rd order), with internal HOAs having the lowest precision (≥0.12 μm). No systematic bias was found between examinations on different days. The intrasession repeatability was high; therefore, the device's ability to measure HOAs in a reliable way was excellent. Under intersession reproducibility conditions, dependable corneal primary spherical aberrations were provided. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
How reproducible is cutaneous electrogastrography? An in-depth evidence-based study.
Jonderko, K; Kasicka-Jonderko, A; Krusiec-Swidergoł, B; Dzielicki, M; Strój, L; Doliński, M; Doliński, K; Błońska-Fajfrowska, B
2005-12-01
To check on reproducibility of parameters of the cutaneous electrogastrogram registered at a close or a distant time span. Twenty-two volunteers recruited by an advertisement (11 females and 11 males, median age 25 years, range: 18-35) underwent three surface electrogastrography examinations of which two were taken on consecutive days and the third one was accomplished at least 2 weeks before or after the two other sessions. The examination involved a 30-min fasted recording, followed by a 90-min postprandial registration after intake of a 394-kcal mixed solid-liquid test meal. Parameters of the electrogastrogram pertaining to the frequency of the gastric slow waves exhibited good to moderate reproducibility, whereas fair reproducibility characterized parameters expected to describe the power of gastric slow waves. With the exception of the difference fed minus fasted power (DeltaDP), in no instance was the medium term reproducibility any worse than the short term one. Categorical data analysis revealed that the relative time share of normogastria postprandially exhibited a better reproducibility than in the fasted period. The Cohen's kappa-value of 0.459 for the DeltaDP for the medium term reproducibility placed this parameter within the range of moderate agreement between repeat examinations. Of the two two-parameter combinations considered, the alliance of the fasted and fed normogastria performed worse than any of those parameters considered alone, whereas a combination of the DeltaDP with the fed-state normogastria revealed a kappa-value amounting to 0.510 for the medium term reproducibility. The feasibility of some electrogastrographic parameters to convey clinically useful information may be hampered by their fair reproducibility. Recoding of parameters of the cutaneous electrogastrogram from primary continuous to secondary categorical may help achieve a better agreement between repeat examinations.
Performance of optical biosensor using alcohol oxidase enzyme for formaldehyde detection
NASA Astrophysics Data System (ADS)
Sari, A. P.; Rachim, A.; Nurlely, Fauzia, V.
2017-07-01
The recent issue in the world is the long exposure of formaldehyde which is can increase the risk of human health, therefore, that is very important to develop a device and method that can be optimized to detect the formaldehyde elements accurately, have a long lifetime and can be fabricated and produced in large quantities. A new and simple prepared optical biosensor for detection of formaldehyde in aqueous solutions using alcohol oxidase (AOX) enzyme was successfully fabricated. The poly-n-butyl acrylic-co-N-acryloxysuccinimide (nBA-NAS) membranes containing chromoionophore ETH5294 were used for immobilization of alcohol oxidase enzyme (AOX). Biosensor response was based on the colour change of chromoionophore as a result of enzymatic oxidation of formaldehyde and correlated with the detection concentration of formaldehyde. The performance of biosensor parameters were measured through the optical absorption value using UV-Vis spectrophotometer including the repeatability, reproducibility, selectivity and lifetime. The results showed that the prepared biosensor has good repeatability (RSD = 1.9 %) and good reproducibility (RSD = 2.1 %). The biosensor was selective formaldehyde with no disturbance by methanol, ethanol, and acetaldehyde, and also stable before 49 days and decrease by 41.77 % after 49 days.
Kolipaka, Arunark; Schroeder, Samuel; Mo, Xiaokui; Shah, Zarine; Hart, Phil A; Conwell, Darwin L
2017-10-01
To determine magnetic resonance elastography (MRE)-derived stiffness of pancreas in healthy volunteers with emphasis on: 1) short term and midterm repeatability; and 2) variance as a function of age. Pancreatic MRE was performed on 22 healthy volunteers (age range:20-64years) in a 3T-scanner. For evaluation of reproducibility of stiffness estimates, the scans were repeated per volunteer on the same day (short term) and one month apart (midterm). MRE wave images were analyzed using 3D inversion to estimate the stiffness of overall pancreas and different anatomic regions (i.e., head, neck, body, and tail). Concordance and Spearman correlation tests were performed to determine reproducibility of stiffness measurements and relationship to age. A strong concordance correlation (ρ c =0.99; p-value<0.001) was found between short term and midterm repeatability pancreatic stiffness measurements. Additionally, the pancreatic stiffness significantly increased with age with good Spearman correlation coefficient (all ρ>0.81; p<0.001). The older age group (>45yrs) had significantly higher stiffness compared to the younger group (≤45yrs) (p<0.001). No significant difference (p>0.05) in stiffness measurements was observed between different anatomical regions of pancreas, except neck stiffness was slightly lower (p<0.012) compared to head and overall pancreas at month 1. MRE-derived pancreatic stiffness measurements are highly reproducible in the short and midterm and increase linearly with age in healthy volunteers. Further studies are needed to examine these effects in patients with various pancreatic diseases to understand potential clinical applications. Copyright © 2017 Elsevier Inc. All rights reserved.
Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.
Carter, J F; Fry, B
2013-03-01
The need for inter-laboratory comparability is crucial to facilitate the globalisation of scientific networks and the development of international databases to support scientific and criminal investigations. This article considers what lessons can be learned from a series of inter-laboratory comparison exercises organised by the Forensic Isotope Ratio Mass Spectrometry (FIRMS) network in terms of reference materials (RMs), the management of data quality, and technical limitations. The results showed that within-laboratory precision (repeatability) was generally good but between-laboratory accuracy (reproducibility) called for improvements. This review considers how stable isotope laboratories can establish a system of quality control (QC) and quality assurance (QA), emphasising issues of repeatability and reproducibility. For results to be comparable between laboratories, measurements must be traceable to the international δ-scales and, because isotope ratio measurements are reported relative to standards, a key aspect is the correct selection, calibration, and use of international and in-house RMs. The authors identify four principles which promote good laboratory practice. The principle of identical treatment by which samples and RMs are processed in an identical manner and which incorporates three further principles; the principle of identical correction (by which necessary corrections are identified and evenly applied), the principle of identical scaling (by which data are shifted and stretched to the international δ-scales), and the principle of error detection by which QC and QA results are monitored and acted upon. To achieve both good repeatability and good reproducibility it is essential to obtain RMs with internationally agreed δ-values. These RMs will act as the basis for QC and can be used to calibrate further in-house QC RMs tailored to the activities of specific laboratories. In-house QA standards must also be developed to ensure that QC-based calibrations and corrections lead to accurate results for samples. The δ-values assigned to RMs must be recorded and reported with all data. Reference materials must be used to determine what corrections are necessary for measured data. Each analytical sequence of samples must include both QC and QA materials which are subject to identical treatment during measurement and data processing. Results for these materials must be plotted, monitored, and acted upon. Periodically international RMs should be analysed as an in-house proficiency test to demonstrate results are accurate.
Precision analysis of a quantitative CT liver surface nodularity score.
Smith, Andrew; Varney, Elliot; Zand, Kevin; Lewis, Tara; Sirous, Reza; York, James; Florez, Edward; Abou Elkassem, Asser; Howard-Claudio, Candace M; Roda, Manohar; Parker, Ellen; Scortegagna, Eduardo; Joyner, David; Sandlin, David; Newsome, Ashley; Brewster, Parker; Lirette, Seth T; Griswold, Michael
2018-04-26
To evaluate precision of a software-based liver surface nodularity (LSN) score derived from CT images. An anthropomorphic CT phantom was constructed with simulated liver containing smooth and nodular segments at the surface and simulated visceral and subcutaneous fat components. The phantom was scanned multiple times on a single CT scanner with adjustment of image acquisition and reconstruction parameters (N = 34) and on 22 different CT scanners from 4 manufacturers at 12 imaging centers. LSN scores were obtained using a software-based method. Repeatability and reproducibility were evaluated by intraclass correlation (ICC) and coefficient of variation. Using abdominal CT images from 68 patients with various stages of chronic liver disease, inter-observer agreement and test-retest repeatability among 12 readers assessing LSN by software- vs. visual-based scoring methods were evaluated by ICC. There was excellent repeatability of LSN scores (ICC:0.79-0.99) using the CT phantom and routine image acquisition and reconstruction parameters (kVp 100-140, mA 200-400, and auto-mA, section thickness 1.25-5.0 mm, field of view 35-50 cm, and smooth or standard kernels). There was excellent reproducibility (smooth ICC: 0.97; 95% CI 0.95, 0.99; CV: 7%; nodular ICC: 0.94; 95% CI 0.89, 0.97; CV: 8%) for LSN scores derived from CT images from 22 different scanners. Inter-observer agreement for the software-based LSN scoring method was excellent (ICC: 0.84; 95% CI 0.79, 0.88; CV: 28%) vs. good for the visual-based method (ICC: 0.61; 95% CI 0.51, 0.69; CV: 43%). Test-retest repeatability for the software-based LSN scoring method was excellent (ICC: 0.82; 95% CI 0.79, 0.84; CV: 12%). The software-based LSN score is a quantitative CT imaging biomarker with excellent repeatability, reproducibility, inter-observer agreement, and test-retest repeatability.
John, Andrew B; Kreisman, Brian M
2017-09-01
Extended high-frequency (EHF) audiometry is useful for evaluating ototoxic exposures and may relate to speech recognition, localisation and hearing aid benefit. There is a need to determine whether common clinical practice for EHF audiometry using tone and noise stimuli is reliable. We evaluated equivalence and compared test-retest (TRT) reproducibility for audiometric thresholds obtained using pure tones and narrowband noise (NBN) from 0.25 to 16 kHz. Thresholds and test-retest reproducibility for stimuli in the conventional (0.25-6 kHz) and EHF (8-16 kHz) frequency ranges were compared in a repeated-measures design. A total of 70 ears of adults with normal hearing. Thresholds obtained using NBN were significantly lower than thresholds obtained using pure tones from 0.5 to 16 kHz, but not 0.25 kHz. Good TRT reproducibility (within 2 dB) was observed for both stimuli at all frequencies. Responses at the lower limit of the presentation range for NBN centred at 14 and 16 kHz suggest unreliability for NBN as a threshold stimulus at these frequencies. Thresholds in the conventional and EHF ranges showed good test-retest reproducibility, but differed between stimulus types. Care should be taken when comparing pure-tone thresholds with NBN thresholds especially at these frequencies.
Reinstein, Dan Z.; Archer, Timothy J.; Silverman, Ronald H.; Coleman, D. Jackson
2008-01-01
Purpose To determine the accuracy, repeatability, and reproducibility of measurement of lateral dimensions using the Artemis (Ultralink LLC) very high-frequency (VHF) digital ultrasound (US) arc scanner. Setting London Vision Clinic, London, United Kingdom. Methods A test object was measured first with a micrometer and then with the Artemis arc scanner. Five sets of 10 consecutive B-scans of the test object were performed with the scanner. The test object was removed from the system between each scan set. One expert observer and one newly trained observer separately measured the lateral dimension of the test object. Two-factor analysis of variance was performed. The accuracy was calculated as the average bias of the scan set averages. The repeatability and reproducibility coefficients were calculated. The coefficient of variation (CV) was calculated for repeatability and reproducibility. Results The test object was measured to be 10.80 mm wide. The mean lateral dimension bias was 0.00 mm. The repeatability coefficient was 0.114 mm. The reproducibility coefficient was 0.026 mm. The repeatability CV was 0.38%, and the reproducibility CV was 0.09%. There was no statistically significant variation between observers (P = .0965). There was a statistically significant variation between scan sets (P = .0036) attributed to minor vertical changes in the alignment of the test object between consecutive scan sets. Conclusion The Artemis VHF digital US arc scanner obtained accurate, repeatable, and reproducible measurements of lateral dimensions of the size commonly found in the anterior segment. PMID:17081860
Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M
2018-02-01
The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
Garcia-Martin, Elena; Pinilla, Isabel; Sancho, Eva; Almarcegui, Carmen; Dolz, Isabel; Rodriguez-Mena, Diego; Fuertes, Isabel; Cuenca, Nicolas
2012-09-01
To evaluate the ability of time-domain and Fourier-domain optical coherence tomographies (OCTs) to detect macular and retinal nerve fiber layer atrophies in retinitis pigmentosa (RP). To test the intrasession reproducibility using three OCT instruments (Stratus, Cirrus, and Spectralis). Eighty eyes of 80 subjects (40 RP patients and 40 healthy subjects) underwent a visual field examination, together with 3 macular scans and 3 optic disk evaluations by the same experienced examiner using 3 OCT instruments. Differences between healthy and RP eyes were compared. The relationship between measurements with each OCT instrument was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation. Macular and retinal nerve fiber layer atrophies were detected in RP patients for all OCT parameters. Macular and retinal nerve fiber layer thicknesses, as determined by the different OCTs, were correlated but significantly different (P < 0.05). Reproducibility was moderately high using Stratus, good using Cirrus and Spectralis, and excellent using the Tru-track technology of Spectralis. In RP eyes, measurements showed higher variability compared with healthy eyes. Differences in thickness measurements existed between OCT instruments, despite there being a high degree of correlation. Fourier-domain OCT can be considered a valid and repeatability technique to detect retinal nerve fiber layer atrophy in RP patients.
Takács, Péter
2016-01-01
We compared the repeatability, reproducibility (intra- and inter-measurer similarity), separative power and subjectivity (measurer effect on results) of four morphometric methods frequently used in ichthyological research, the “traditional” caliper-based (TRA) and truss-network (TRU) distance methods and two geometric methods that compare landmark coordinates on the body (GMB) and scales (GMS). In each case, measurements were performed three times by three measurers on the same specimen of three common cyprinid species (roach Rutilus rutilus (Linnaeus, 1758), bleak Alburnus alburnus (Linnaeus, 1758) and Prussian carp Carassius gibelio (Bloch, 1782)) collected from three closely-situated sites in the Lake Balaton catchment (Hungary) in 2014. TRA measurements were made on conserved specimens using a digital caliper, while TRU, GMB and GMS measurements were undertaken on digital images of the bodies and scales. In most cases, intra-measurer repeatability was similar. While all four methods were able to differentiate the source populations, significant differences were observed in their repeatability, reproducibility and subjectivity. GMB displayed highest overall repeatability and reproducibility and was least burdened by measurer effect. While GMS showed similar repeatability to GMB when fish scales had a characteristic shape, it showed significantly lower reproducability (compared with its repeatability) for each species than the other methods. TRU showed similar repeatability as the GMS. TRA was the least applicable method as measurements were obtained from the fish itself, resulting in poor repeatability and reproducibility. Although all four methods showed some degree of subjectivity, TRA was the only method where population-level detachment was entirely overwritten by measurer effect. Based on these results, we recommend a) avoidance of aggregating different measurer’s datasets when using TRA and GMS methods; and b) use of image-based methods for morphometric surveys. Automation of the morphometric workflow would also reduce any measurer effect and eliminate measurement and data-input errors. PMID:27327896
Fischer, A; Luginbühl, T; Delattre, L; Delouard, J M; Faverdin, P
2015-07-01
Body condition is an indirect estimation of the level of body reserves, and its variation reflects cumulative variation in energy balance. It interacts with reproductive and health performance, which are important to consider in dairy production but not easy to monitor. The commonly used body condition score (BCS) is time consuming, subjective, and not very sensitive. The aim was therefore to develop and validate a method assessing BCS with 3-dimensional (3D) surfaces of the cow's rear. A camera captured 3D shapes 2 m from the floor in a weigh station at the milking parlor exit. The BCS was scored by 3 experts on the same day as 3D imaging. Four anatomical landmarks had to be identified manually on each 3D surface to define a space centered on the cow's rear. A set of 57 3D surfaces from 56 Holstein dairy cows was selected to cover a large BCS range (from 0.5 to 4.75 on a 0 to 5 scale) to calibrate 3D surfaces on BCS. After performing a principal component analysis on this data set, multiple linear regression was fitted on the coordinates of these surfaces in the principal components' space to assess BCS. The validation was performed on 2 external data sets: one with cows used for calibration, but at a different lactation stage, and one with cows not used for calibration. Additionally, 6 cows were scanned once and their surfaces processed 8 times each for repeatability and then these cows were scanned 8 times each the same day for reproducibility. The selected model showed perfect calibration and a good but weaker validation (root mean square error=0.31 for the data set with cows used for calibration; 0.32 for the data set with cows not used for calibration). Assessing BCS with 3D surfaces was 3 times more repeatable (standard error=0.075 versus 0.210 for BCS) and 2.8 times more reproducible than manually scored BCS (standard error=0.103 versus 0.280 for BCS). The prediction error was similar for both validation data sets, indicating that the method is not less efficient for cows not used for calibration. The major part of reproducibility error incorporates repeatability error. An automation of the anatomical landmarks identification is required, first to allow broadband measures of body condition and second to improve repeatability and consequently reproducibility. Assessing BCS using 3D imaging coupled with principal component analysis appears to be a very promising means of improving precision and feasibility of this trait measurement. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Wassenaar, Peter A; Eleswarpu, Chethanya N; Schroeder, Samuel A; Mo, Xiaokui; Raterman, Brian D; White, Richard D; Kolipaka, Arunark
2015-01-01
Purpose To assess reproducibility in measuring left ventricular (LV) myocardial stiffness in volunteers throughout the cardiac cycle using magnetic resonance elastography (MRE) and to determine its correlation with age. Methods Cardiac MRE (CMRE) was performed on 29 normal volunteers, with ages ranging from 21 to 73 years. For assessing reproducibility of CMRE-derived stiffness measurements, scans were repeated per volunteer. Wave images were acquired throughout the LV myocardium, and were analyzed to obtain mean stiffness during the cardiac cycle. CMRE-derived stiffness values were correlated to age. Results Concordance correlation coefficient revealed good inter-scan agreement with rc of 0.77, with p-value<0.0001. Significantly higher myocardial stiffness was observed during end-systole (ES) compared to end-diastole (ED) across all subjects. Additionally, increased deviation between ES and ED stiffness was observed with increased age. Conclusion CMRE-derived stiffness is reproducible, with myocardial stiffness changing cyclically across the cardiac cycle. Stiffness is significantly higher during ES compared to ED. With age, ES myocardial stiffness increases more than ED, giving rise to an increased deviation between the two. PMID:26010456
A wide range and highly sensitive optical fiber pH sensor using polyacrylamide hydrogel
NASA Astrophysics Data System (ADS)
Pathak, Akhilesh Kumar; Singh, Vinod Kumar
2017-12-01
In the present study we report the fabrication and characterization of no-core fiber sensor (NCFS) using smart hydrogel coating for pH measurement. The no-core fiber (NCF) is stubbed between two single-mode fibers with SMA connector before immobilizing of smart hydrogel. The wavelength interrogation technique is used to calculate the sensitivity of the proposed sensor. The result shows a high sensitivity of 1.94 nm/pH for a wide range of pH values varied from 3 to 10 with a good linear response. In addition to high sensitivity, the fabricated sensor provides a fast response time with a good stability, repeatability and reproducibility.
Dang, Natasha Radhika; Moreau, Marc J; Hill, Douglas L; Mahood, James K; Raso, James
2005-05-01
Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.
Thermoluminescent properties of some phosphor glasses based on aluminum oxide.
El Mesady, I; Khaled, N; Hussein, A; El Samman, H; Alawsh, S
2016-12-01
The transparent thermoluminescent aluminum oxide-based glass of 15Al 2 O 3 -35P 2 O 5 -25CaO-25Na 2 CO 3 , abbreviated as APCN (all in mol%) doped with different concentrations of SiO 2 from 0.0-500 ppm was prepared using a conventional melt-quenching technique. The TL sensitivities of the prepared glasses were investigated at 3 Gy γ-dose using a 60 Co source and measured at a heating rate 10 C/sec. The highest TL intensity of the material doped with SiO 2 was found at a concentration of 500 ppm (APCNSi 5 ). Deconvolution of the glow curve from APCNSi 5 resulted in four peaks at about 161, 194, 237 and 293 C with a Figure Of Merit (FOM) of 1.28%. The APCNSi 5 specimen had the best dosimetric properties when compared with the other samples. Reproducibility, repeatability, dose-response curve and fading effect were checked for peak 3, which appeared at about 237 C. The results displayed that the APCNSi 5 glass system was a low-Z material (Z eff ≈ 10), and had good reproducibility and good repeatability. Peak 3 showed good linearity over a dose range up to 20 Gy (R 2 = 0.999) and sublinearity behaviour was found. The signal from APCNSi 5 faded by about 11% after 2 days post irradiation, therefore it showed almost no significant loss. Such properties make the newly prepared glasses suitable for and highly recommended for use in γ-dosimeters. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Percival, Elizabeth; Bhatia, Rani; Preece, Kahn; McElduff, Patrick; McEvoy, Mark; Collison, Adam; Mattes, Joerg
2016-01-01
Ara h2 sIgE serum levels improve the diagnostic accuracy for predicting peanut allergy, but the use of Ara h2 purified protein as a skin prick test (SPT), has not been substantially evaluated. The fraction of exhaled nitric oxide (FeNO) shows promise as a novel biomarker of peanut allergy. Reproducibility of these measures has not been determined. The aim was to assess the accuracy and reproducibility (over a time-period of at least 12 months) of SPT to Ara h2 in comparison with four predictors of clinical peanut allergy (Peanut SPT, Ara h2 specific Immunoglobulin E (sIgE), Peanut sIgE and FeNO). Twenty-seven children were recruited in a follow-up of a prospective cohort of fifty-six children at least 12 months after an open-labelled peanut food challenge. Their repeat assessment involved a questionnaire, SPT to peanut and Ara h2 purified protein, FeNO and sIgE to peanut and Ara h2 measurements. Ara h2 SPT was no worse in accuracy when compared with peanut SPT, FeNO, Ara h2 sIgE and peanut sIgE (AUC 0.908 compared with 0.887, 0.889, 0.935 and 0.804 respectively) for predicting allergic reaction at previous food challenge. SPT for peanut and Ara h2 demonstrated limited reproducibility (ICC = 0.51 and 0.44); while FeNO demonstrated good reproducibility (ICC = 0.73) and sIgE for peanut and Ara h2 were highly reproducible (ICC = 0.81 and 0.85). In this population, Ara h2 SPT was no worse in accuracy when compared with current testing for the evaluation of clinical peanut allergy, but had-like peanut SPT-poor reproducibility. FeNO, peanut sIgE and Ara h2 sIgE were consistently reproducible despite an interval of at least 12 months between the repeated measurements.
De Monte, Anne; Cannavo, Isabelle; Caramella, Anne; Ollier, Laurence; Giordanengo, Valérie
2016-01-01
Congenital cytomegalovirus (CMV) infection is the leading cause of sensoneurinal disability due to infectious congenital disease. The diagnosis of congenital CMV infection is based on the search of CMV in the urine within the first two weeks of life. Viral culture of urine is the gold standard. However, the PCR is highly sensitive and faster. It is becoming an alternative choice. The objective of this study is the validation of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine. Repeatability, reproducibility, detection limit and inter-sample contamination were evaluated. Urine samples from patients (n=141) were collected and analyzed simultaneously in culture and PCR in order to assess the correlation of these two methods. The sensitivity and specificity of PCR were also calculated. The Abbott RealTime CMV PCR in urine is an automated and sensitive method (detection limit 200 UI/mL). Fidelity is very good (standard deviation of repeatability: 0.08 to 0.15 LogUI/mL and reproducibility 0.18 LogUI/mL). We can note a good correlation between culture and Abbott RealTime CMV PCR (kappa 96%). When considering rapid culture as reference, real-time PCR was highly sensitive (100%) and specific (98.2%). The real-time PCR by Abbott RealTime CMV with m2000 is optimal for CMV detection in urine.
Grillo, Andrea; Parati, Gianfranco; Rovina, Matteo; Moretti, Francesco; Salvi, Lucia; Gao, Lan; Baldi, Corrado; Sorropago, Giovanni; Faini, Andrea; Millasseau, Sandrine C; Scalise, Filippo; Carretta, Renzo; Salvi, Paolo
2017-12-08
Aortic pulse wave velocity (PWV) is an indirect index of arterial stiffness and an independent cardiovascular risk factor. Consistency of PWV assessment over time is thus an essential feature for its clinical application. However, studies providing a comparative estimate of the reproducibility of PWV across different noninvasive devices are lacking, especially in the elderly and in individuals at high cardiovascular risk. Aimed at filling this gap, short-term repeatability of PWV, estimated with 6 different devices (Complior Analyse, PulsePen-ETT, PulsePen-ET, SphygmoCor Px/Vx, BPLab, and Mobil-O-Graph), was evaluated in 102 high cardiovascular risk patients hospitalized for suspected coronary artery disease (72 males, 65 ± 13 years). PWV was measured in a single session twice, at 15-minute interval, and its reproducibility was assessed though coefficient of variation (CV), coefficient of repeatability, and intraclass correlation coefficient. The CV of PWV, measured with any of these devices, was <10%. Repeatability was higher with cuff-based methods (BPLab: CV = 5.5% and Mobil-O-Graph: CV = 3.4%) than with devices measuring carotid-femoral PWV (Complior: CV = 8.2%; PulsePen-TT: CV = 8.0%; PulsePen-ETT: CV = 5.8%; and SphygmoCor: CV = 9.5%). In the latter group, PWV repeatability was lower in subjects with higher carotid-femoral PWV. The differences in PWV between repeated measurements, except for the Mobil-O-Graph, did not depend on short-term variations of mean blood pressure or heart rate. Our study shows that the short-term repeatability of PWV measures is good but not homogenous across different devices and at different PWV values. These findings, obtained in patients at high cardiovascular risk, may be relevant when evaluating the prognostic importance of PWV. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com
NASA Astrophysics Data System (ADS)
Chen, Chieh-Li; Bojikian, Karine D.; Xin, Chen; Wen, Joanne C.; Gupta, Divakar; Zhang, Qinqin; Mudumbai, Raghu C.; Johnstone, Murray A.; Chen, Philip P.; Wang, Ruikang K.
2016-06-01
Optical coherence tomography angiography (OCTA) has increasingly become a clinically useful technique in ophthalmic imaging. We evaluate the repeatability and reproducibility of blood perfusion in the optic nerve head (ONH) measured using optical microangiography (OMAG)-based OCTA. Ten eyes from 10 healthy volunteers are recruited and scanned three times with a 68-kHz Cirrus HD-OCT 5000-based OMAG prototype system (Carl Zeiss Meditec Inc., Dublin, California) centered at the ONH involving two separate visits within six weeks. Vascular images are generated with OMAG processing by detecting the differences in OCT signals between consecutive B-scans acquired at the same retina location. ONH perfusion is quantified as flux, vessel area density, and normalized flux within the ONH for the prelaminar, lamina cribrosa, and the full ONH. Coefficient of variation (CV) and intraclass correlation coefficient (ICC) are used to evaluate intravisit and intervisit repeatability, and interobserver reproducibility. ONH perfusion measurements show high repeatability [CV≤3.7% (intravisit) and ≤5.2% (intervisit)] and interobserver reproducibility (ICC≤0.966) in all three layers by three metrics. OCTA provides a noninvasive method to visualize and quantify ONH perfusion in human eyes with excellent repeatability and reproducibility, which may add additional insight into ONH perfusion in clinical practice.
Yang, X; Yang, Y; Zhou, R; Bian, L
2001-11-01
For studying the contents of dietary fiber in general foods and functional foods, a enzymatic-gravimetric method recommended by AOAC was established in our laboratory. The method for the determination of total, soluble and insoluble dietary fiber in foods and functional foods could be used for many other kind of foods. The relative standard deviations (RSD) of reproducibility between-run and within-run were 2.04%-7.85%, 3.42%-55.23% respectively. The repeatability of the methods was good, and the methods are suitable for many foods.
Berlinger, Balazs; Harper, Martin
2018-02-01
There is interest in the bioaccessible metal components of aerosols, but this has been minimally studied because standardized sampling and analytical methods have not yet been developed. An interlaboratory study (ILS) has been carried out to evaluate a method for determining the water-soluble component of realistic welding fume (WF) air samples. Replicate samples were generated in the laboratory and distributed to participating laboratories to be analyzed according to a standardized procedure. Within-laboratory precision of replicate sample analysis (repeatability) was very good. Reproducibility between laboratories was not as good, but within limits of acceptability for the analysis of typical aerosol samples. These results can be used to support the development of a standardized test method.
Bolca, Selin; Huybrechts, Inge; Verschraegen, Mia; De Henauw, Stefaan; Van de Wiele, Tom
2009-01-01
A novel food-frequency questionnaire (FFQ) was developed and validated to assess the usual daily fat, saturated, mono-unsaturated and poly-unsaturated fatty acid, fibre, alcohol, caffeine, and theobromine intakes among Belgian post-menopausal women participating in dietary intervention trials with phyto-oestrogens. The relative validity of the FFQ was estimated by comparison with 7 day (d) estimated diet records (EDR, n 64) and its reproducibility was evaluated by repeated administrations 6 weeks apart (n 79). Although the questionnaire underestimated significantly all intakes compared to the 7 d EDR, it had a good ranking ability (r 0.47–0.94; weighted κ 0.25–0.66) and it could reliably distinguish extreme intakes for all the estimated nutrients, except for saturated fatty acids. Furthermore, the correlation between repeated administrations was high (r 0.71–0.87) with a maximal misclassification of 7% (weighted κ 0.33–0.80). In conclusion, these results compare favourably with those reported by others and indicate that the FFQ is a satisfactorily reliable and valid instrument for ranking individuals within this study population. PMID:19440274
Tabb, David L.; Vega-Montoto, Lorenzo; Rudnick, Paul A.; Variyath, Asokan Mulayath; Ham, Amy-Joan L.; Bunk, David M.; Kilpatrick, Lisa E.; Billheimer, Dean D.; Blackman, Ronald K.; Cardasis, Helene L.; Carr, Steven A.; Clauser, Karl R.; Jaffe, Jacob D.; Kowalski, Kevin A.; Neubert, Thomas A.; Regnier, Fred E.; Schilling, Birgit; Tegeler, Tony J.; Wang, Mu; Wang, Pei; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Fisher, Susan J.; Gibson, Bradford W.; Kinsinger, Christopher R.; Mesri, Mehdi; Rodriguez, Henry; Stein, Steven E.; Tempst, Paul; Paulovich, Amanda G.; Liebler, Daniel C.; Spiegelman, Cliff
2009-01-01
The complexity of proteomic instrumentation for LC-MS/MS introduces many possible sources of variability. Data-dependent sampling of peptides constitutes a stochastic element at the heart of discovery proteomics. Although this variation impacts the identification of peptides, proteomic identifications are far from completely random. In this study, we analyzed interlaboratory data sets from the NCI Clinical Proteomic Technology Assessment for Cancer to examine repeatability and reproducibility in peptide and protein identifications. Included data spanned 144 LC-MS/MS experiments on four Thermo LTQ and four Orbitrap instruments. Samples included yeast lysate, the NCI-20 defined dynamic range protein mix, and the Sigma UPS 1 defined equimolar protein mix. Some of our findings reinforced conventional wisdom, such as repeatability and reproducibility being higher for proteins than for peptides. Most lessons from the data, however, were more subtle. Orbitraps proved capable of higher repeatability and reproducibility, but aberrant performance occasionally erased these gains. Even the simplest protein digestions yielded more peptide ions than LC-MS/MS could identify during a single experiment. We observed that peptide lists from pairs of technical replicates overlapped by 35–60%, giving a range for peptide-level repeatability in these experiments. Sample complexity did not appear to affect peptide identification repeatability, even as numbers of identified spectra changed by an order of magnitude. Statistical analysis of protein spectral counts revealed greater stability across technical replicates for Orbitraps, making them superior to LTQ instruments for biomarker candidate discovery. The most repeatable peptides were those corresponding to conventional tryptic cleavage sites, those that produced intense MS signals, and those that resulted from proteins generating many distinct peptides. Reproducibility among different instruments of the same type lagged behind repeatability of technical replicates on a single instrument by several percent. These findings reinforce the importance of evaluating repeatability as a fundamental characteristic of analytical technologies. PMID:19921851
Repeatability and Reproducibility of Decisions by Latent Fingerprint Examiners
Ulery, Bradford T.; Hicklin, R. Austin; Buscaglia, JoAnn; Roberts, Maria Antonia
2012-01-01
The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. We tested latent print examiners on the extent to which they reached consistent decisions. This study assessed intra-examiner repeatability by retesting 72 examiners on comparisons of latent and exemplar fingerprints, after an interval of approximately seven months; each examiner was reassigned 25 image pairs for comparison, out of total pool of 744 image pairs. We compare these repeatability results with reproducibility (inter-examiner) results derived from our previous study. Examiners repeated 89.1% of their individualization decisions, and 90.1% of their exclusion decisions; most of the changed decisions resulted in inconclusive decisions. Repeatability of comparison decisions (individualization, exclusion, inconclusive) was 90.0% for mated pairs, and 85.9% for nonmated pairs. Repeatability and reproducibility were notably lower for comparisons assessed by the examiners as “difficult” than for “easy” or “moderate” comparisons, indicating that examiners' assessments of difficulty may be useful for quality assurance. No false positive errors were repeated (n = 4); 30% of false negative errors were repeated. One percent of latent value decisions were completely reversed (no value even for exclusion vs. of value for individualization). Most of the inter- and intra-examiner variability concerned whether the examiners considered the information available to be sufficient to reach a conclusion; this variability was concentrated on specific image pairs such that repeatability and reproducibility were very high on some comparisons and very low on others. Much of the variability appears to be due to making categorical decisions in borderline cases. PMID:22427888
Khodr, Zeina G.; Sak, Mark A.; Pfeiffer, Ruth M.; Duric, Nebojsa; Littrup, Peter; Bey-Knight, Lisa; Ali, Haythem; Vallieres, Patricia; Sherman, Mark E.; Gierach, Gretchen L.
2015-01-01
Purpose: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. Methods: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (two scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors’ experienced rater. Results: Median (range) time between baseline and follow-up UST scans was five (1–13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater’s repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. Conclusions: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density. PMID:26429241
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khodr, Zeina G.; Pfeiffer, Ruth M.; Gierach, Gretchen L., E-mail: GierachG@mail.nih.gov
Purpose: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. Methods: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (twomore » scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors’ experienced rater. Results: Median (range) time between baseline and follow-up UST scans was five (1–13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater’s repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. Conclusions: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density.« less
Automated 3D ultrasound measurement of the angle of progression in labor.
Montaguti, Elisa; Rizzo, Nicola; Pilu, Gianluigi; Youssef, Aly
2018-01-01
To assess the feasibility and reliability of an automated technique for the assessment of the angle of progression (AoP) in labor by using three-dimensional (3D) ultrasound. AoP was assessed by using 3D transperineal ultrasound by two operators in 52 women in active labor to evaluate intra- and interobserver reproducibility. Furthermore, intermethod agreement between automated and manual techniques on 3D images, and between automated technique on 3D vs 2D images were evaluated. Automated measurements were feasible in all cases. Automated measurements were considered acceptable in 141 (90.4%) out of the 156 on the first assessments and in all 156 after repeating measurements for unacceptable evaluations. The automated technique on 3D images demonstrated good intra- and interobserver reproducibility. The 3D-automated technique showed a very good agreement with the 3D manual technique. Notably, AoP calculated with the 3D automated technique were significantly wider in comparison with those measured manually on 3D images (133 ± 17° vs 118 ± 21°, p = 0.013). The assessment of the angle of progression through 3D ultrasound is highly reproducible. However, automated software leads to a systematic overestimation of AoP in comparison with the standard manual technique thus hindering its use in clinical practice in its present form.
NASA Astrophysics Data System (ADS)
Liu, Ying; Tao, Lu-Qi; Wang, Dan-Yang; Zhang, Tian-Yu; Yang, Yi; Ren, Tian-Ling
2017-03-01
In this paper, a flexible, simple-preparation, and low-cost graphene-silk pressure sensor based on soft silk substrate through thermal reduction was demonstrated. Taking silk as the support body, the device had formed a three-dimensional structure with ordered multi-layer structure. Through a simple and low-cost process technology, graphene-silk pressure sensor can achieve the sensitivity value of 0.4 kPa - 1 , and the measurement range can be as high as 140 kPa. Besides, pressure sensor can have a good combination with knitted clothing and textile product. The signal had good reproducibility in response to different pressures. Furthermore, graphene-silk pressure sensor can not only detect pressure higher than 100 kPa, but also can measure weak body signals. The characteristics of high-sensitivity, good repeatability, flexibility, and comfort for skin provide the high possibility to fit on various wearable electronics.
Steigen, Terje K; Claudio, Cheryl; Abbott, David; Schulzer, Michael; Burton, Jeff; Tymchak, Wayne; Buller, Christopher E; John Mancini, G B
2008-06-01
To assess reproducibility of core laboratory performance and impact on sample size calculations. Little information exists about overall reproducibility of core laboratories in contradistinction to performance of individual technicians. Also, qualitative parameters are being adjudicated increasingly as either primary or secondary end-points. The comparative impact of using diverse indexes on sample sizes has not been previously reported. We compared initial and repeat assessments of five quantitative parameters [e.g., minimum lumen diameter (MLD), ejection fraction (EF), etc.] and six qualitative parameters [e.g., TIMI myocardial perfusion grade (TMPG) or thrombus grade (TTG), etc.], as performed by differing technicians and separated by a year or more. Sample sizes were calculated from these results. TMPG and TTG were also adjudicated by a second core laboratory. MLD and EF were the most reproducible, yielding the smallest sample size calculations, whereas percent diameter stenosis and centerline wall motion require substantially larger trials. Of the qualitative parameters, all except TIMI flow grade gave reproducibility characteristics yielding sample sizes of many 100's of patients. Reproducibility of TMPG and TTG was only moderately good both within and between core laboratories, underscoring an intrinsic difficulty in assessing these. Core laboratories can be shown to provide reproducibility performance that is comparable to performance commonly ascribed to individual technicians. The differences in reproducibility yield huge differences in sample size when comparing quantitative and qualitative parameters. TMPG and TTG are intrinsically difficult to assess and conclusions based on these parameters should arise only from very large trials.
Procedures for estimating confidence intervals for selected method performance parameters.
McClure, F D; Lee, J K
2001-01-01
Procedures for estimating confidence intervals (CIs) for the repeatability variance (sigmar2), reproducibility variance (sigmaR2 = sigmaL2 + sigmar2), laboratory component (sigmaL2), and their corresponding standard deviations sigmar, sigmaR, and sigmaL, respectively, are presented. In addition, CIs for the ratio of the repeatability component to the reproducibility variance (sigmar2/sigmaR2) and the ratio of the laboratory component to the reproducibility variance (sigmaL2/sigmaR2) are also presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stannett, V.T.
1989-01-04
Hexachlorophosphazene was irradiated in bulk and in solution after various methods of purification. When rigorously dried and purified, good yields of polymer were obtained. Poor reproducibility was found in the bulk but reasonably good results were obtained in decalin solution. The best yields and highest molecular weights were obtained after the addition of small amounts of the bulky electron acceptor pyromellitic dianhydride. Hexachlorocyclotriphosphazene was purified by recrystallization for various times from dried heptane. The trimer was then further purified by repeated sublimation steps under high vacuum. Finally the trimer was dried in the melt over rigorously baked out barium oxide.more » The monomer was then transferred to ampules or the NMR tubes for radiation and subsequent determination of the polymer content.« less
Toward the Standardization of Biochar Analysis: The COST Action TD1107 Interlaboratory Comparison.
Bachmann, Hans Jörg; Bucheli, Thomas D; Dieguez-Alonso, Alba; Fabbri, Daniele; Knicker, Heike; Schmidt, Hans-Peter; Ulbricht, Axel; Becker, Roland; Buscaroli, Alessandro; Buerge, Diane; Cross, Andrew; Dickinson, Dane; Enders, Akio; Esteves, Valdemar I; Evangelou, Michael W H; Fellet, Guido; Friedrich, Kevin; Gasco Guerrero, Gabriel; Glaser, Bruno; Hanke, Ulrich M; Hanley, Kelly; Hilber, Isabel; Kalderis, Dimitrios; Leifeld, Jens; Masek, Ondrej; Mumme, Jan; Carmona, Marina Paneque; Calvelo Pereira, Roberto; Rees, Frederic; Rombolà, Alessandro G; de la Rosa, José Maria; Sakrabani, Ruben; Sohi, Saran; Soja, Gerhard; Valagussa, Massimo; Verheijen, Frank; Zehetner, Franz
2016-01-20
Biochar produced by pyrolysis of organic residues is increasingly used for soil amendment and many other applications. However, analytical methods for its physical and chemical characterization are yet far from being specifically adapted, optimized, and standardized. Therefore, COST Action TD1107 conducted an interlaboratory comparison in which 22 laboratories from 12 countries analyzed three different types of biochar for 38 physical-chemical parameters (macro- and microelements, heavy metals, polycyclic aromatic hydrocarbons, pH, electrical conductivity, and specific surface area) with their preferential methods. The data were evaluated in detail using professional interlaboratory testing software. Whereas intralaboratory repeatability was generally good or at least acceptable, interlaboratory reproducibility was mostly not (20% < mean reproducibility standard deviation < 460%). This paper contributes to better comparability of biochar data published already and provides recommendations to improve and harmonize specific methods for biochar analysis in the future.
2013-01-01
Background The aim was to compare the repeatability, reproducibility and inherent precision of ultrasound pachymetry (USP), noncontact specular microscopy (SP-2000P) and the Confoscan 4 confocal microscope (z-ring CS4) in measuring endothelial cell density (ECD), coefficient of variation of cell size (CV), and central corneal thickness (CCT) in normal eyes. Methods In this prospective study, one eye was selected from each of 30 subjects for the measurements of ECD, CV and CCT, which were taken by two observers. Results were analyzed statistically by repeated-measures analysis of variance (ANOVA) for intra-observer repeatability, inter-observer reproducibility, unpaired t-test, paired t-test, and Bland–Altman analyses to determine limits of agreement (LOA) between the three instruments. Results Mean ECD, measured by SP-2000P and z-ring CS4, were 3115.50 ± 279.70 cells/mm2 and 3167.50 ± 264.75 cells/mm2, respectively (observer 1), and 3192.63 ± 249.42 cells/mm2 (z-ring, observer 2). Mean CV measurements were 27.12 ± 2.51 and 27.10 ± 2.41 (SP-2000P and z-ring CS4, respectively; observer 1), and 27.17 ± 2.25 (z-ring, observer 2). Mean CCT values were 555.11 ± 35.83 μm (USP), 535.82 ± 41.10 μm (SP-2000P) and 552.57 ± 36.83 μm (z-ring CS4), and 554.97 ± 36.34 μm (z-ring CS4, observer 2). However, pairwise tests in all cases there was good repeatability and reproducibility as shown by inter-observer and intra-observer analysis of variance for each of the instruments. Conclusions The SP-2000P and the z-ring CS4 can be used interchangeably to measure ECD and CV. For CCT, the sample size was too small to test for differences of the CCT measurements between the three instruments. PMID:24274022
Optically stimulated Al2O3:C luminescence dosimeters for teletherapy: Hp(10) performance evaluation.
Hashim, S; Musa, Y; Ghoshal, S K; Ahmad, N E; Hashim, I H; Yusop, M; Bradley, D A; Kadir, A B A
2018-05-01
The performance of optically stimulated luminescence dosimeters (OSLDs, Al 2 O 3 :C) was evaluated in terms of the operational quantity of H P (10) in Co-60 external beam teletherapy unit. The reproducibility, signal depletion, and dose linearity of each dosimeter was investigated. For ten repeated readouts, each dosimeter exposed to 50mSv was found to be reproducible below 1.9 ± 3% from the mean value, indicating good reader stability. Meanwhile, an average signal reduction of 0.5% per readout was found. The dose response revealed a good linearity within the dose range of 5-50mSv having nearly perfect regression line with R 2 equals 0.9992. The accuracy of the measured doses were evaluated in terms of operational quantity H P (10), wherein the trumpet curve method was used respecting the 1990 International Commission on Radiological Protection (ICRP) standard. The accuracy of the overall measurements from all dosimeters was discerned to be within the trumpet curve and devoid of outlier. It is established that the achieved OSL Al 2 O 3 :C dosimeters are greatly reliable for equivalent dose assessment. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Holland, A. A.; Ringler, A. T.; Wilson, D.
2016-12-01
We attempt to estimate lower bounds on the repeatability for a number of common instrumentation parameters and provide estimates on the errors associated with the instrument installation itself. These parameters include the self-noise, the orientation, and the sensitivity. We installed three Trillium Compact instruments within 30 cm of each other in the same seismic vault at the Albuquerque Seismological Laboratory. We then repeatedly uninstall and reinstall one of the Trillium Compact instruments multiple times, while leaving the other two in place as reference installations. Using these trials we are then able to examine how repeatable several parameters are between the two reference instruments and the other instrument. We also completely uninstalled and reinstalled the three seismometers once during the testing, in order to examine the reproducibility of the entire experiment. Results indicate that relative sensitivity is highly repeatable, which is partly why we chose this particular sensor for this evaluation. We find that self-noise in the band of 0.1 to 30 s period of an instrument is repeatable to within about 2 dB. Increasing the period of interest from 30 to 100 s period we observe that the self-noise of an instrument can only be repeated to within about 3 dB and that the relative self-noise is not repeatable amongst the sensors. We also find that even though the seismometers are centimeters apart on a single marked line, that the relative orientation between installations is only repeatable to within 1-2 degrees. However, the relative orientations are reproducible, that is, with each installation the relative orientations are within the same amount of uncertainty. Some other broadband or very broadband instruments may not show as much repeatability between installations for some of the metrics we examined. From these tests we can say that instrument self-noise tests are reproducible to within a few dB.
Gough, Lewis Anthony; Deb, Sanjoy Kumar; Sparks, Andy; McNaughton, Lars Robert
2017-09-21
Individual time to peak blood bicarbonate (HCO 3 - ) has demonstrated good to excellent reproducibility following ingestion of both 0.2 g kg -1 body mass (BM) and 0.3 g kg -1 BM sodium bicarbonate (NaHCO 3 ), but the consistency of the time trial (TT) performance response using such an individualised NaHCO 3 ingestion strategy remains unknown. This study therefore evaluated the reproducibility of 4-km TT performance following NaHCO 3 ingestion individualised to time to peak blood bicarbonate. Eleven trained male cyclists completed five randomised treatments with prior ingestion of 0.2 g kg -1 (SBC2) or 0.3 g kg -1 BM (SBC3) NaHCO 3 , on two separate occasions each, or a control trial entailing no supplementation. Participants completed a 4-km cycling TT on a Velotron ergometer where time to complete, power and speed were measured, whilst acid-base blood parameters were also recorded (pH and blood bicarbonate concentration HCO 3 - ) and lactate [La - ]. Alkalosis was achieved prior to exercise in both SBC2 and SBC3, as pH and HCO 3 - were greater compared to baseline (p < 0.001), with no differences between treatments (p > 0.05). The reproducibility of the mean absolute change from baseline to peak in HCO 3 - was good in SBC2 (r = 0.68) and excellent in SBC3 (r = 0.78). The performance responses following both SBC2 and SBC3 displayed excellent reproducibility (r range = 0.97 to 0.99). Results demonstrate excellent reproducibility of exercise performance following individualised NaHCO 3 ingestion, which is due to the high reproducibility of blood acid-base variables with repeat administration of NaHCO 3 . Using a time to peak HCO 3 - strategy seems to cause no dose-dependent effects on performance for exercise of this duration and intensity; therefore, athletes may consider smaller doses of NaHCO 3 to mitigate gastrointestinal (GI) discomfort.
Fallaize, Rosalind; Forster, Hannah; Macready, Anna L; Walsh, Marianne C; Mathers, John C; Brennan, Lorraine; Gibney, Eileen R; Gibney, Michael J
2014-01-01
Background Advances in nutritional assessment are continuing to embrace developments in computer technology. The online Food4Me food frequency questionnaire (FFQ) was created as an electronic system for the collection of nutrient intake data. To ensure its accuracy in assessing both nutrient and food group intake, further validation against data obtained using a reliable, but independent, instrument and assessment of its reproducibility are required. Objective The aim was to assess the reproducibility and validity of the Food4Me FFQ against a 4-day weighed food record (WFR). Methods Reproducibility of the Food4Me FFQ was assessed using test-retest methodology by asking participants to complete the FFQ on 2 occasions 4 weeks apart. To assess the validity of the Food4Me FFQ against the 4-day WFR, half the participants were also asked to complete a 4-day WFR 1 week after the first administration of the Food4Me FFQ. Level of agreement between nutrient and food group intakes estimated by the repeated Food4Me FFQ and the Food4Me FFQ and 4-day WFR were evaluated using Bland-Altman methodology and classification into quartiles of daily intake. Crude unadjusted correlation coefficients were also calculated for nutrient and food group intakes. Results In total, 100 people participated in the assessment of reproducibility (mean age 32, SD 12 years), and 49 of these (mean age 27, SD 8 years) also took part in the assessment of validity. Crude unadjusted correlations for repeated Food4Me FFQ ranged from .65 (vitamin D) to .90 (alcohol). The mean cross-classification into “exact agreement plus adjacent” was 92% for both nutrient and food group intakes, and Bland-Altman plots showed good agreement for energy-adjusted macronutrient intakes. Agreement between the Food4Me FFQ and 4-day WFR varied, with crude unadjusted correlations ranging from .23 (vitamin D) to .65 (protein, % total energy) for nutrient intakes and .11 (soups, sauces and miscellaneous foods) to .73 (yogurts) for food group intake. The mean cross-classification into “exact agreement plus adjacent” was 80% and 78% for nutrient and food group intake, respectively. There were no significant differences between energy intakes estimated using the Food4Me FFQ and 4-day WFR, and Bland-Altman plots showed good agreement for both energy and energy-controlled nutrient intakes. Conclusions The results demonstrate that the online Food4Me FFQ is reproducible for assessing nutrient and food group intake and has moderate agreement with the 4-day WFR for assessing energy and energy-adjusted nutrient intakes. The Food4Me FFQ is a suitable online tool for assessing dietary intake in healthy adults. PMID:25113936
Oxygen-weighted Hyperpolarized 3He MR Imaging: A Short-term Reproducibility Study in Human Subjects
Ishii, Masaru; Hamedani, Hooman; Clapp, Justin T.; Kadlecek, Stephen J.; Xin, Yi; Gefter, Warren B.; Rossman, Milton D.
2015-01-01
Purpose To determine whether hyperpolarized helium 3 magnetic resonance (MR) imaging to measure alveolar partial pressure of oxygen (Pao2) shows sufficient test-retest repeatability and between-cohort differences to be used as a reliable technique for detection of alterations in gas exchange in asymptomatic smokers. Materials and Methods The protocol was approved by the local institutional review board and was HIPAA compliant. Informed consent was obtained from all subjects. Two sets of MR images were obtained 10 minutes apart in 25 subjects: 10 nonsmokers (five men, five women; mean ± standard deviation age, 50 years ± 6) and 15 smokers (seven women, eight men; mean age, 50 years ± 8). A mixed-effects model was developed to identify the regional repeatability of Pao2 measurements as an intraclass correlation coefficient. Ten smokers were matched with the 10 nonsmokers on the basis of signal-to-noise ratio (SNR). Three separate models were generated: one for nonsmokers, one for the SNR-matched smokers, and one for the five remaining smokers, who were imaged with a significantly higher SNR. Results Short-term back-to-back regional reproducibility was assessed by using intraclass correlation coefficients, which were 0.67 and 0.65 for SNR case-matched nonsmokers and smokers, respectively. Repeatability was a strong function of SNR; a 50% increase in SNR in the remaining smokers improved the intraclass correlation coefficient to 0.82. Although repeatability was not significantly different between the SNR-matched cohorts (P = .44), the smoker group showed higher spatial and temporal variability in Pao2. Conclusion The short-term test-retest repeatability of hyperpolarized gas MR imaging of regional Pao2 was good. Asymptomatic smokers exhibited greater spatial and temporal variability in Pao2 than did the nonsmokers, which suggests that this parameter allows detection of small functional alterations associated with smoking. © RSNA, 2015 Online supplemental material is available for this article. PMID:26110668
Di Leo, Giovanni; D'Angelo, Ida Daniela; Alì, Marco; Cannaò, Paola Maria; Mauri, Giovanni; Secchi, Francesco; Sardanelli, Francesco
2017-03-01
The aim of our study was to estimate the intra- and inter-reader reproducibility of blood flow measurements in the ascending aorta and main pulmonary artery using cardiac magnetic resonance (CMR) and a semi-automated segmentation method. The ethics committee approved this retrospective study. A total of 50 consecutive patients (35 males and 15 females; mean age±standard deviation 27±13 years) affected by congenital heart disease were reviewed. They underwent CMR for flow analysis of the ascending aorta and main pulmonary artery (1.5 T, through-plane phase-contrast sequences). Two independent readers (R1, trained radiology resident; R2, lower-trained technician student) obtained segmented images twice (>10-day interval), using a semi-automated method of segmentation. Peak velocity, forward and backward flows were obtained. Bland-Altman analysis was used and reproducibility was reported as complement to 100% of the ratio between the coefficient of repeatability and the mean. R1 intra-reader reproducibility for the aorta was 99% (peak velocity), 95% (forward flow) and 49% (backward flow); for the pulmonary artery, 99%, 91% and 90%, respectively. R2 intra-reader reproducibility was 92%, 91% and 38%; 98%, 86% and 87%, respectively. Inter-reader reproducibility for the aorta was 91%, 85% and 20%; for the pulmonary artery 96%, 75%, and 82%, respectively. Our results showed a good to excellent reproducibility of blood flow measurements of CMR together with a semiautomated method of segmentation, for all variables except the backward flow of the ascending aorta, with a limited impact of operator's training.
Strampe, Margaret R; Huckenpahler, Alison L; Higgins, Brian P; Tarima, Sergey; Visotcky, Alexis; Stepien, Kimberly E; Kay, Christine N; Carroll, Joseph
2018-05-01
To examine repeatability and reproducibility of ellipsoid zone (EZ) width measurements in patients with retinitis pigmentosa (RP) using a longitudinal reflectivity profile (LRP) analysis. We examined Bioptigen optical coherence tomography (OCT) scans from 48 subjects with RP or Usher syndrome. Nominal scan lengths were 6, 7, or 10 mm, and the lateral scale of each scan was calculated using axial length measurements. LRPs were generated from OCT line scans, and the peak corresponding to EZ was manually identified using ImageJ. The locations at which the EZ peak disappeared were used to calculate EZ width. Each scan was analyzed twice by each of two observers, who were masked to their previous measurements and those of the other observer. On average, horizontal width (HW) was significantly greater than vertical width (VW), and there was high interocular symmetry for both HW and VW. We observed excellent intraobserver repeatability with intraclass correlation coefficients (ICCs) ranging from 0.996 to 0.998 for HW and VW measurements. Interobserver reproducibility was also excellent for both HW (ICC = 0.989; 95% confidence interval [CI] = 0.983-0.995) and VW (ICC = 0.991; 95% CI = 0.985-0.996), with no significant bias observed between observers. EZ width can be measured using LRPs with excellent repeatability and reproducibility. Our observation of greater HW than VW is consistent with previous observations in RP, though the reason for this anisotropy remains unclear. We describe repeatability and reproducibility of a method for measuring EZ width in patients with RP or Usher syndrome. This approach could facilitate measurement of retinal band thickness and/or intensity.
Vinke, Elisabeth J; Kortenbout, Anna J; Eyding, Jens; Slump, Cornelis H; van der Hoeven, Johannes G; de Korte, Chris L; Hoedemaekers, Cornelia W E
2017-12-01
Contrast-enhanced ultrasound (CEUS) has been suggested as a new method to measure cerebral perfusion in patients with acute brain injury. In this systematic review, the tolerability, repeatability, reproducibility and accuracy of different CEUS techniques for the quantification of cerebral perfusion were assessed. We selected studies published between January 1994 and March 2017 using CEUS to measure cerebral perfusion. We included 43 studies (bolus kinetics n = 31, refill kinetics n = 6, depletion kinetics n = 6) with a total of 861 patients. Tolerability was reported in 28 studies describing 12 patients with mild and transient side effects. Repeatability was assessed in 3 studies, reproducibility in 2 studies and accuracy in 19 studies. Repeatability was high for experienced sonographers and significantly lower for less experienced sonographers. Reproducibility of CEUS was not clear. The sensitivity and specificity of CEUS for the detection of cerebral ischemia ranged from 75% to 96% and from 60% to 100%. Limited data on repeatability, reproducibility and accuracy may suggest that this technique could be feasible for use in acute brain injury patients. Copyright © 2017 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.
Reliability of a portable device for the detection of sleep bruxism.
Deregibus, Andrea; Castroflorio, Tommaso; Bargellini, Andrea; Debernardi, Cesare
2014-11-01
The aim of the study was to assess the repeatability in detecting sleep bruxism (SB) episodes by combined surface electromyography and heart rate (HR) signals recorded by a compact portable device (Bruxoff®). SB episodes are preceded by a sudden HR change. Thus, HR detection increases the precision of automatic detection of SB. Ten healthy subjects (five women and five men; 30.2 ± 11.02 years) were selected for the study. Rhythmic masseter muscle activities, constituting the basic pattern of SB, were detected during three nights of recording during three different weeks with the Bruxoff device. The two-way ANOVA was not significant for SB episodes per night, SB episodes per hour, and heart frequency: no significant differences were observed during the three different nights of recording for each of the abovementioned variables (P > 0.05). The intraclass correlation coefficient showed a good reproducibility for SB episodes per night (69 %), SB per hour (74 %), and heart frequency (82 %). A poor reproducibility was revealed for the number of masseter contractions (53 %). The Pearson analysis showed the absence of a significant correlation between the number of masseter contractions per night and the number of SB episodes per night (r = -0.02, P = 0.91). The Bruxoff device showed a good reproducibility of measurements of sleep bruxism episodes over time. These findings are important in the light of the need for simple and reliable portable devices for the diagnosis of SB both in the clinical and research settings.
[The application of non-annealing thermoluminescent dosimetry (TLD)].
Wu, J M; Chen, C S; Lan, R H
1993-06-01
Conventional use of Thermoluminescence (TL) in radiation dosimetry is very time-consuming. It requires repeating the procedures of preheating and annealing. In an attempt to simplify these procedures, we conducted an experiment of non-annealing TL dosimetry. This article reports the experiment's results. We adopted Lithium Fluoride (LiF) chip (TLD-100) in polystyrene under the exposure of Co-60, and the result was taken by HAR-SHAW-4000 TL reading system. The TL response was analyzed, including linearity, reproducibility and fading test. Because non-annealing TL response was greatly influenced by residual electron, TLD calibration curves were separated into two parts: (1) high dose region (HDR, 50-1500 cGy); (2) low dose region (LDR, 0-50 cGy). When TL dosimeters were exposed to a single high does (about 500 cGy), the HDR could be reproduced within 3% and fit a good linearity. For LDR, we had to give up the tail of glow curve in the high temperature region. We could then get good linearity and reproducibility. Furthermore, fading of non-annealing was apparently larger than annealing. We could control the fading of non-annealing was apparently larger than annealing. We could control the fading influence within 1% by taking the TL reading one hour after exposure. On the other hand, a combination of photon and electron exposure was also performed by non-annealing TL dosimetry. The results were compatible with Co-60 exposure in the same system.
Reproducibility of radiomics for deciphering tumor phenotype with imaging
NASA Astrophysics Data System (ADS)
Zhao, Binsheng; Tan, Yongqiang; Tsai, Wei-Yann; Qi, Jing; Xie, Chuanmiao; Lu, Lin; Schwartz, Lawrence H.
2016-03-01
Radiomics (radiogenomics) characterizes tumor phenotypes based on quantitative image features derived from routine radiologic imaging to improve cancer diagnosis, prognosis, prediction and response to therapy. Although radiomic features must be reproducible to qualify as biomarkers for clinical care, little is known about how routine imaging acquisition techniques/parameters affect reproducibility. To begin to fill this knowledge gap, we assessed the reproducibility of a comprehensive, commonly-used set of radiomic features using a unique, same-day repeat computed tomography data set from lung cancer patients. Each scan was reconstructed at 6 imaging settings, varying slice thicknesses (1.25 mm, 2.5 mm and 5 mm) and reconstruction algorithms (sharp, smooth). Reproducibility was assessed using the repeat scans reconstructed at identical imaging setting (6 settings in total). In separate analyses, we explored differences in radiomic features due to different imaging parameters by assessing the agreement of these radiomic features extracted from the repeat scans reconstructed at the same slice thickness but different algorithms (3 settings in total). Our data suggest that radiomic features are reproducible over a wide range of imaging settings. However, smooth and sharp reconstruction algorithms should not be used interchangeably. These findings will raise awareness of the importance of properly setting imaging acquisition parameters in radiomics/radiogenomics research.
ZnO Nanorods Based Enzymatic Biosensor for Selective Determination of Penicillin
Ibupoto, Zafar Hussain; Ali, Syed Muhammad Usman; Khun, Kimleang; Chey, Chan Oeurn; Nur, Omer; Willander, Magnus
2011-01-01
In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoyloxysuccinimide (ANB-NOS) as cross linking molecules. The potentiometric response of the sensor configuration revealed good linearity over a large logarithmic concentration range from 100 µM to 100 mM. During the investigations, the proposed sensor showed a good stability with high sensitivity of ~121 mV/decade for sensing of penicillin. A quick electrochemical response of less than 5 s with a good selectivity, repeatability, reproducibility and a negligible response to common interferents such as Na1+, K1+, d-glucose, l-glucose, ascorbic acid, uric acid, urea, sucrose, lactose, glycine, penicilloic acid and cephalosporins, was observed. PMID:25585565
ZnO Nanorods Based Enzymatic Biosensor for Selective Determination of Penicillin.
Ibupoto, Zafar Hussain; Ali, Syed Muhammad Usman; Khun, Kimleang; Chey, Chan Oeurn; Nur, Omer; Willander, Magnus
2011-10-27
In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoyloxysuccinimide (ANB-NOS) as cross linking molecules. The potentiometric response of the sensor configuration revealed good linearity over a large logarithmic concentration range from 100 µM to 100 mM. During the investigations, the proposed sensor showed a good stability with high sensitivity of ~121 mV/decade for sensing of penicillin. A quick electrochemical response of less than 5 s with a good selectivity, repeatability, reproducibility and a negligible response to common interferents such as Na1+, K1+, d-glucose, l-glucose, ascorbic acid, uric acid, urea, sucrose, lactose, glycine, penicilloic acid and cephalosporins, was observed.
A six-year longitudinal PET study of (+)-[11C]DTBZ binding to the VMAT2 in monkey brain.
Kilbourn, Michael R; Koeppe, Robert A
2017-12-01
The longitudinal reproducibility of in vivo binding potential measures for [ 11 C]dihydrotetrabenazine ([ 11 C]DTBZ) binding to the vesicular monoamine transporter 2 (VMAT2) site in primate brain was examined using a unique dataset of repeated control PET imaging studies. Forty-one dynamic [ 11 C]DTBZ PET studies were completed in a single rhesus monkey. Imaging equipment (microPET P4), personnel, radiotracer characteristics (injected mass amounts, molar activity) and image data analysis (BP ND-Logan ) were consistent throughout the entire sequence of PET studies. Same day reproducibility of BP ND-Logan estimates of specific binding was very good (-3% and -7% changes) for two control-control sessions. Over the full 74 months, the average BP ND-Logan value for [ 11 C]DTBZ-PET studies was 4.19±0.52, for a variance of 12%. No age-dependent change in binding potentials was observed over the six-year period. If the technical variables associated with PET scanner are consistently maintained, including PET scanner, imaging procedures and radiotracer preparation, in vivo biochemistry can be reproducibly measured in the primate brain over a multi-year period of time. Copyright © 2017 Elsevier Inc. All rights reserved.
You, Qisheng; Freeman, William R; Weinreb, Robert N; Zangwill, Linda; Manalastas, Patricia I C; Saunders, Luke J; Nudleman, Eric
2017-08-01
To determine the intravisit and intervisit reproducibility of optical coherence tomography angiography measurements of macular vessel density in eyes with and without retinal diseases. Fifteen healthy volunteers and 22 patients with retinal diseases underwent repeated optical coherence tomography angiography (Angiovue Imaging System, Optovue Inc) scans after pupil dilation on 2 separate visit days. For each visit day, the eyes were scanned twice. Vessel density defined as the proportion of vessel area with flowing blood over the total measurement area was calculated using Angiovue software. Intravisit and intervisit reproducibility were summarized as coefficient of variations and intraclass correlation coefficients were calculated from variance component models. The coefficient of variations representing the intravisit reproducibility of the superficial macular vessel density measurements for different quadrants on 3 mm × 3-mm scans varied from 2.1% to 4.9% and 3.4% to 6.8% for healthy and diseased eyes, respectively, and for the intervisit it was 2.9% to 5.1% and 4.0% to 6.8%, respectively. The coefficient of variations were lower in healthy eyes than in diseased eyes, lower for intravisit than for intervisit, lower on 3 mm × 3-mm scans than on 6 mm × 6-mm scans, and lower for paracentral subfields than for central subfield. The evidence presented here demonstrates good reproducibility of optical coherence tomography angiography for measurement of superficial macula vessel density in both healthy eyes and eyes with diabetic retinopathy without diabetic macular edema.
[Validity and Reliability of Two Silhouette Scales to Asses the Body Image in Adolescent Students].
Rueda-Jaimes, Germán Eduardo; López, Paul Anthony Camacho; Flórez, Silvia Milena; Martínez-Villalba, Andrés Mauricio Rangel
2012-03-01
To determine the validity and reliability of the 13-figure images scale (13-CS) and Standard Figural Stimuli (SFS) for the evaluation of body images in adolescent students from Bucaramanga. A probabilistic sample with 189 students was evaluated with the two scales. Two weeks later, the valuation together with the size, weight, percentage of body fat, SCOFF questionnaire and Rosenberg self-esteem valuation was repeated. The average age was 14.1 years; 62.7% were women. The correlation of the 13-CS and SFS with body fat index, weight and body fat percentage was 0.61, 0.74, 0.40 and 0.72, 0.55, 0.45 respectively. The correlation of dissatisfaction with body image according to the SCOFF and the Rosenberg scales was 0.43 and 0.26 with the 13-CS; 0.50 and -0.23 with the SFS. The reproducibility shows that perceived and ideal figure was 0.93 and 0.90 with the 13-CS; and 0.85 and 0.78 with the SFS. the concurrent validity of both scales was good. The reproducibility of the 13-CS was excellent while the SFS was good. Copyright © 2012 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.
Hynd, David; Depinet, Paul; Lorenz, Bernd
2013-01-01
The United Nations Economic Commission for Europe Informal Group on GTR No. 7 Phase 2 are working to define a build level for the BioRID II rear impact (whiplash) crash test dummy that ensures repeatable and reproducible performance in a test procedure that has been proposed for future legislation. This includes the specification of dummy hardware, as well as the development of comprehensive certification procedures for the dummy. This study evaluated whether the dummy build level and certification procedures deliver the desired level of repeatability and reproducibility. A custom-designed laboratory seat was made using the seat base, back, and head restraint from a production car seat to ensure a representative interface with the dummy. The seat back was reinforced for use in multiple tests and the recliner mechanism was replaced by an external spring-damper mechanism. A total of 65 tests were performed with 6 BioRID IIg dummies using the draft GTR No.7 sled pulse and seating procedure. All dummies were subject to the build, maintenance, and certification procedures defined by the Informal Group. The test condition was highly repeatable, with a very repeatable pulse, a well-controlled seat back response, and minimal observed degradation of seat foams. The results showed qualitatively reasonable repeatability and reproducibility for the upper torso and head accelerations, as well as for T1 Fx and upper neck Fx . However, reproducibility was not acceptable for T1 and upper neck Fz or for T1 and upper neck My . The Informal Group has not selected injury or seat assessment criteria for use with BioRID II, so it is not known whether these channels would be used in the regulation. However, the ramping-up behavior of the dummy showed poor reproducibility, which would be expected to affect the reproducibility of dummy measurements in general. Pelvis and spine characteristics were found to significantly influence the dummy measurements for which poor reproducibility was observed. It was also observed that the primary neck response in these tests was flexion, not extension. This correlates well with recent findings from Japan and the United States showing a correlation between neck flexion and injury in accident replication simulations and postmortem human subjects (PMHS) studies, respectively. The present certification tests may not adequately control front cervical spine bumper characteristics, which are important for neck flexion response. The certification sled test also does not include the pelvis and so cannot be used to control pelvis response and does not substantially load the lumbar bumpers and so does not control these parts of the dummy. The stiffness of all spine bumpers and of the pelvis flesh should be much more tightly controlled. It is recommended that a method for certifying the front cervical bumpers should be developed. Recommendations are also made for tighter tolerance on the input parameters for the existing certification tests.
Reproducibility of Echocardiograph-Derived Multilevel Left Ventricular Apical Twist Mechanics.
Stewart, Glenn M; Yamada, Akira; Kavanagh, Justin J; Haseler, Luke J; Chan, Jonathan; Sabapathy, Surendran
2016-02-01
Left ventricular (LV) twist mechanics are routinely assessed via echocardiography in clinical and research trials investigating the function of obliquely oriented myocardial fibers. However, echocardiograph-derived measures of LV twist may be compromised by nonstandardized acquisition of the apical image. This study examined the reproducibility of echocardiograph-derived parameters of apical twist mechanics at multiple levels of the apical myocardium. Two sets of 2D LV parasternal short-axis images were obtained in 30 healthy subjects (24 men; 19-57 year) via echocardiography. Images were acquired immediately distal to the papillary muscles (apical image 1), immediately above the point of LV cavity obliteration at end systole (apical image 3), and midway between apical image 1 and apical image 3 (apical image 2). Repeat scans were performed within 1 hour, and twist mechanics (rotation and rotation rate) were calculated via frame-by-frame tracking of natural acoustic echocardiographic markers (speckle tracking). The magnitude of apical rotation increased progressively toward the apex (apical image 1: 4.2 ± 2.1°, apical image 2: 7.2 ± 3.9°, apical image 3: 11.8 ± 4.6°). apical images 1, 2, and 3 each had moderate to good correlations between repeat scans (ICC: 0.531-0.856). When apical images 1, 2, and 3 were averaged, rotation was 7.7 ± 2.7° and between-scan correlation was excellent (ICC: 0.910). Similar results were observed for systolic and diastolic rotation rates. Averaging multiple standardized apical images, tending progressively toward the apex, generated the most reproducible rotation indices and may be optimal for the assessment of LV twist mechanics across therapeutic, interventional, and research studies; however, care should be taken given the influence of acquisition level on the magnitude of apical rotation. © 2015, Wiley Periodicals, Inc.
Clément, Julien; Raison, Maxime; Rouleau, Dominique M
2018-02-08
None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, particularly in terms of reproducibility. Therefore, this study aims to evaluate the reproducibility of the reachable workspace over a period of several weeks, and to assess the effects of two proposed acquisition protocols, as well as those of gender, and hand dominancy. Shoulder movements were recorded using a motion capture system on 10 female and 10 male healthy subjects during a random protocol, i.e. simply asking them to achieve the farthest points they could reach with their hands, and during a standardized protocol, i.e. asking them to perform predefined shoulder elevations while keeping their trunk and elbow straight. The standardized protocol was repeated 7 weeks later. Repeated measures showed no significant difference, good to excellent intraclass correlation coefficients (0.46-0.81) and small bias (0.0-1.2%). The random protocol provided significantly lower and more scattered values for the reachable workspace (80.0 ± 22.6% vs. 91.0 ± 8.1%, p = .004), whereas gender and hand-dominancy had no effect. This study showed that the reachable workspace was highly reliable over a period of 7 weeks and that both upper limbs provided similar results. It could be used to monitor various pathologies of the upper limbs and to assess treatment efficiency, using a subject's healthy limb as reference. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lewis, Ryan C.; Hauser, Russ; Maynard, Andrew D.; Neitzel, Richard L.; Wang, Lu; Kavet, Robert; Morey, Patricia; Ford, Jennifer B.; Meeker, John D.
2016-01-01
Power-frequency magnetic field exposure science as it relates to men and couples have not been explored despite the advantage of this information in the design and interpretation of reproductive health epidemiology studies. This analysis examined the distribution and temporal variability of exposures in men, and the correlation of exposures within couples using data from a longitudinal study of 25 men and their female partners recruited from an infertility clinic. The average and 90th percentile demonstrated fair to good reproducibility, whereas the maximum showed poor reproducibility over repeated sampling days, each separated by a median of 4.6 weeks. Average magnetic field exposures were also strongly correlated within couples, suggesting that one partner's data could be used as a surrogate in the absence of data from the other for this metric. Environment was also an important effect modifier in these explored matters. These issues should be considered in future relevant epidemiology studies. PMID:26705359
Ferasin, Luca; Marcora, Samuele
2009-10-01
Thirteen healthy Labrador retrievers underwent a 5-stage incremental treadmill exercise test to assess its reliability. Blood lactate (BL), heart rate (HR), and body temperature (BT) were measured at rest, after each stage of exercise, and after a 20-min recovery. Reproducibility was assessed by repeating the test after 7 days. Two-way MANOVAs revealed significant differences between consecutive stages, and between values at rest and after recovery. There was also a significant reduction in physiological strain between the first and second trial (learning effect). Test reliability expressed as typical error (BL = 0.22 mmol/l, HR = 9.81 bpm, BT = 0.22 degrees C), coefficient of variation (BL = 19.3%, HR = 7.9% and BT = 0.6%) and test-retest correlation (BL = 0.89, HR = 0.96, BT = 0.95) was good. Results support test reproducibility although the learning effect needs to be controlled when investigating the exercise-related problems commonly observed in this breed.
McClure, Foster D; Lee, Jung K
2005-01-01
Sample size formulas are developed to estimate the repeatability and reproducibility standard deviations (Sr and S(R)) such that the actual error in (Sr and S(R)) relative to their respective true values, sigmar and sigmaR, are at predefined levels. The statistical consequences associated with AOAC INTERNATIONAL required sample size to validate an analytical method are discussed. In addition, formulas to estimate the uncertainties of (Sr and S(R)) were derived and are provided as supporting documentation. Formula for the Number of Replicates Required for a Specified Margin of Relative Error in the Estimate of the Repeatability Standard Deviation.
Zhang, Jingwei; Zhou, Dong; Nguyen, Thanh D; Spincemaille, Pascal; Gupta, Ajay; Wang, Yi
2017-05-01
Our objective was to demonstrate the feasibility of using hyperventilation as an efficient vasoconstrictive challenge and prior knowledge as denoising constraints for cerebral metabolic rate of oxygen (CMRO 2 ) mapping based upon quantitative susceptibility mapping (QSM). Three-dimensional (3D) multi-echo gradient echo and arterial spin labeling imaging were performed to calculate QSM and perfusion maps before and after a hyperventilation challenge in 11 healthy subjects. For comparison, this was repeated using a caffeine challenge. Whole-brain CMRO 2 and oxygen extraction fraction (OEF) maps were computed using constrained optimization. Hyperventilation scans were repeated to measure reproducibility. Regional agreement of CMRO 2 and OEF maps was analyzed within the cortical gray matter (CGM) using t-test and Bland-Altman plots. Hyperventilation challenge eliminates the 30-min waiting time needed for caffeine to exert its vasoconstrictive effects. Mean CMRO 2 (in µmol/100g/min) obtained in CGM using the caffeine and repeated hyperventilation scans were 149 ± 16, 153 ± 19, and 150 ± 20, respectively. This corresponded to an OEF of 33.6 ± 3.4%, 32.3 ± 3.2%, and 34.1 ± 3.8% at baseline state and 39.8 ± 4.8%, 43.6 ± 6.2%, and 42.8 ± 6.8% at challenged state, respectively. Hyperventilation scans produced a good agreement of CMRO 2 and OEF values. Hyperventilation is a feasible, reproducible, and efficient vasoconstrictive challenge for QSM-based quantitative CMRO 2 mapping. Magn Reson Med 77:1762-1773, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Vargas, Hebert Alberto; Kramer, Gem M; Scott, Andrew M; Weickhardt, Andrew; Meier, Andreas A; Parada, Nicole; Beattie, Bradley J; Humm, John L; Staton, Kevin D; Zanzonico, Pat B; Lyashchenko, Serge K; Lewis, Jason S; Yaqub, Maqsood; Sosa, Ramon E; van den Eertwegh, Alfons J; Davis, Ian D; Ackermann, Uwe; Pathmaraj, Kunthi; Schuit, Robert C; Windhorst, Albert D; Chua, Sue; Weber, Wolfgang A; Larson, Steven M; Scher, Howard I; Lammertsma, Adriaan A; Hoekstra, Otto; Morris, Michael J
2018-04-06
18 F-fluorodihydrotestosterone ( 18 F-FDHT) is a radiolabeled analogue of the androgen receptor's primary ligand that is currently being credentialed as a biomarker for prognosis, response, and pharmacodynamic effects of new therapeutics. As part of the biomarker qualification process, we prospectively assessed its reproducibility and repeatability in men with metastatic castration-resistant prostate cancer (mCRPC). Methods: We conducted a prospective multi-institutional study of mCRPC patients undergoing two (test/re-test) 18 F-FDHT PET/CT scans on two consecutive days. Two independent readers evaluated all examinations and recorded standardized uptake values (SUVs), androgen receptor-positive tumor volumes (ARTV), and total lesion uptake (TLU) for the most avid lesion detected in each of 32 pre-defined anatomical regions. The relative absolute difference and reproducibility coefficient (RC) of each metric were calculated between the test and re-test scans. Linear regression analyses, intra-class correlation coefficients (ICC), and Bland-Altman plots were used to evaluate repeatability of 18 F-FDHT metrics. The coefficient of variation (COV) and ICC were used to assess inter-observer reproducibility. Results: Twenty-seven patients with 140 18 F-FDHT-avid regions were included. The best repeatability among 18 F-FDHT uptake metrics was found for SUV metrics (SUV max , SUVmean, and SUVpeak), with no significant differences in repeatability found among them. Correlations between the test and re-test scans were strong for all SUV metrics (R2 ≥ 0.92; ICC ≥ 0.97). The RCs of the SUV metrics ranged from 21.3% for SUVpeak to 24.6% for SUV max The test and re-test ARTV and TLU, respectively, were highly correlated (R2 and ICC ≥ 0.97), although variability was significantly higher than that for SUV (RCs > 46.4%). The PSA levels, Gleason score, weight, and age did not affect repeatability, nor did total injected activity, uptake measurement time, or differences in uptake time between the two scans. Including the single most avid lesion per patient, the five most avid lesions per patient, only lesions ≥ 4.2 mL, only lesions with an SUV ≥ 4 g/mL, or normalizing of SUV to area under the parent plasma activity concentration-time curve did not significantly affect repeatability. All metrics showed high inter-observer reproducibility (ICC > 0.98; COV < 0.2-10.8%). Conclusion: 18 F-FDHT is a highly reproducible means of imaging mCRPC. Amongst 18 F-FDHT uptake metrics, SUV had the highest repeatability among the measures assessed. These performance characteristics lend themselves to further biomarker development and clinical qualification of the tracer. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Dimitriadis, Alexis; Palmer, Antony L; Thomas, Russell A S; Nisbet, Andrew; Clark, Catharine H
2017-06-01
To adapt and validate an anthropomorphic head phantom for use in a cranial radiosurgery audit. Two bespoke inserts were produced for the phantom: one for providing the target and organ at risk for delineation and the other for performing dose measurements. The inserts were tested to assess their positional accuracy. A basic treatment plan dose verification with an ionization chamber was performed to establish a baseline accuracy for the phantom and beam model. The phantom and inserts were then used to perform dose verification measurements of a radiosurgery plan. The dose was measured with alanine pellets, EBT extended dose film and a plastic scintillation detector (PSD). Both inserts showed reproducible positioning (±0.5 mm) and good positional agreement between them (±0.6 mm). The basic treatment plan measurements showed agreement to the treatment planning system (TPS) within 0.5%. Repeated film measurements showed consistent gamma passing rates with good agreement to the TPS. For 2%-2 mm global gamma, the mean passing rate was 96.7% and the variation in passing rates did not exceed 2.1%. The alanine pellets and PSD showed good agreement with the TPS (-0.1% and 0.3% dose difference in the target) and good agreement with each other (within 1%). The adaptations to the phantom showed acceptable accuracies. The presence of alanine and PSD do not affect film measurements significantly, enabling simultaneous measurements by all three detectors. Advances in knowledge: A novel method for thorough end-to-end test of radiosurgery, with capability to incorporate all steps of the clinical pathway in a time-efficient and reproducible manner, suitable for a national audit.
Lee, Michele D; Kaidonis, Georgia; Kim, Alice Y; Shields, Ryan A; Leng, Theodore
2017-09-01
Choroidal nevi are common benign intraocular tumors with a small risk of malignant transformation. This retrospective study investigates the use of en face spectral-domain optical coherence tomography angiography (SD-OCTA) in determining the clinical features and measurement of choroidal nevi. Patients with choroidal nevi were imaged with both OCTA and a fundus photography device. Greatest longitudinal dimension (GLD), perpendicular dimension (PD), and the GLD/PD ratio were assessed on each device. Inter-device variation and intra- and inter-rater reliability analyses were performed. Fourteen patients with choroidal nevi were included. No significant difference between the GLD/PD ratio as measured by all three devices was found (Chi-square = 2.8, 2 df, P = .247). Intraclass correlation coefficients were greater than 0.7 for repeated measures on all devices, suggesting good repeatability and reproducibility. This study demonstrated inter-device consistency and high intra- and inter-rater reliability when measuring choroidal nevi. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:741-747.]. Copyright 2017, SLACK Incorporated.
Central Corneal Thickness Reproducibility among Ten Different Instruments.
Pierro, Luisa; Iuliano, Lorenzo; Gagliardi, Marco; Ambrosi, Alessandro; Rama, Paolo; Bandello, Francesco
2016-11-01
To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852-0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon-Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss-RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device.
Mokhles, Palwasha; van den Bosch, Annemien E; Vletter-McGhie, Jackie S; Van Domburg, Ron T; Ruys, Titia P E; Kauer, Floris; Geleijnse, Marcel L; Roos-Hesselink, Jolien W
2013-09-01
The twisting motion of the heart has an important role in the function of the left ventricle. Speckle tracking echocardiography is able to quantify left ventricular (LV) rotation and twist. So far this new technique has not been used in congenital heart disease patients. The aim of our study was to investigate the feasibility and the intra- and inter-observer reproducibility of LV rotation parameters in adult patients with congenital heart disease. The study population consisted of 66 consecutive patients seen in the outpatient clinic (67% male, mean age 31 ± 7.7 years, NYHA class 1 ± 0.3) with a variety of congenital heart disease. First, feasibility was assessed in all patients. Intra- and inter-observer reproducibility was assessed for the patients in which speckle tracking echocardiography was feasible. Adequate image quality, for performing speckle echocardiography, was found in 80% of patients. The bias for the intra-observer reproducibility of the LV twist was 0.0°, with 95% limits of agreement of -2.5° and 2.5° and for interobserver reproducibility the bias was 0.0°, with 95% limits of agreement of -3.0° and 3.0°. Intra- and inter-observer measurements showed a strong correlation (0.86 and 0.79, respectively). Also a good repeatability was seen. The mean time to complete full analysis per subject for the first and second measurement was 9 and 5 minutes, respectively. Speckle tracking echocardiography is feasible in 80% of adult patients with congenital heart disease and shows excellent intra- and inter-observer reproducibility. © 2013, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Song, Tingting; Liu, Qi; Liu, Jingyuan; Yang, Wanlu; Chen, Rongrong; Jing, Xiaoyan; Takahashi, Kazunobu; Wang, Jun
2015-11-01
Inspired by natural plants such as Nepenthes pitcher plants, super slippery surfaces have been developed to improve the attributes of repellent surfaces. In this report, super slippery porous anodic aluminium oxide (AAO) surfaces have fabricated by a simple and reproducible method. Firstly, the aluminium substrates were treated by an anodic process producing micro-nano structured sheet-layered pores, and then immersed in Methyl Silicone Oil, Fluororalkylsilane (FAS) and DuPont Krytox, respectively, generating super slippery surfaces. Such a good material with excellent anti-corrosion property through a simple and repeatable method may be potential candidates for metallic application in anti-corrosion and extreme environment.
Dezawa, Akira; Sairyo, Koichi
2014-05-01
Organic electroluminescence displays (OELD) use organic materials that self-emit light with the passage of an electric current. OELD provide high contrast, excellent color reproducibility at low brightness, excellent video images, and less restricted viewing angles. OELD are thus promising for medical use. This study compared the utility of an OELD with conventional liquid crystal displays (LCD) for imaging in orthopedic endoscopic surgery. One OELD and two conventional LCD that were indistinguishable in external appearance were used in this study. Images from 18 patients were displayed simultaneously on three monitors and evaluated by six orthopedic surgeons with extensive surgical experience. Images were shown for 2 min, repeated twice, and viewed from the front and side (diagonally). Surgeon rated both clinical utility (12 parameters) and image quality (11 parameters) for each image on a 5-point scale: 1, very good; 2, good; 3, average; 4, poor; and 5, very poor. For clinical utility in 16 percutaneous endoscopic discectomy cases, mean scores for all 12 parameters were significantly better on the OELD than on the LCD, including organ distinguishability (2.1 vs 3.2, respectively), lesion identification (2.2 vs 3.1), and overall viewing impression (2.1 vs 3.1). For image quality, all 11 parameters were better on the OELD than on LCD. Significant differences were identified in six parameters, including contrast (1.8 vs 2.9), color reproducibility in dark areas (1.8 vs 2.9), and viewing angle (2.2 vs 2.9). The high contrast and excellent color reproducibility of the OELD reduced the constraints of imaging under endoscopy, in which securing a field of view may be difficult. Distinguishability of organs was good, including ligaments, dura mater, nerves, and adipose tissue, contributing to good stereoscopic images of the surgical field. These findings suggest the utility of OELD for excellent display of surgical images and for enabling safe and highly accurate endoscopic surgery. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
Virtual laboratories: new opportunities for collaborative water science
NASA Astrophysics Data System (ADS)
Ceola, Serena; Arheimer, Berit; Bloeschl, Guenter; Baratti, Emanuele; Capell, Rene; Castellarin, Attilio; Freer, Jim; Han, Dawei; Hrachowitz, Markus; Hundecha, Yeshewatesfa; Hutton, Christopher; Lindström, Goran; Montanari, Alberto; Nijzink, Remko; Parajka, Juraj; Toth, Elena; Viglione, Alberto; Wagener, Thorsten
2015-04-01
Reproducibility and repeatability of experiments are the fundamental prerequisites that allow researchers to validate results and share hydrological knowledge, experience and expertise in the light of global water management problems. Virtual laboratories offer new opportunities to enable these prerequisites since they allow experimenters to share data, tools and pre-defined experimental procedures (i.e. protocols). Here we present the outcomes of a first collaborative numerical experiment undertaken by five different international research groups in a virtual laboratory to address the key issues of reproducibility and repeatability. Moving from the definition of accurate and detailed experimental protocols, a rainfall-runoff model was independently applied to 15 European catchments by the research groups and model results were collectively examined through a web-based discussion. We found that a detailed modelling protocol was crucial to ensure the comparability and reproducibility of the proposed experiment across groups. Our results suggest that sharing comprehensive and precise protocols and running the experiments within a controlled environment (e.g. virtual laboratory) is as fundamental as sharing data and tools for ensuring experiment repeatability and reproducibility across the broad scientific community and thus advancing hydrology in a more coherent way.
Maas, M; Akkerman, E M; Venema, H W; Stoker, J; Den Heeten, G J
2001-01-01
The purpose of this work was to explore the reproducibility of fat-fraction measurements using Dixon quantitative chemical shift imaging (QCSI) in the lumbar spine (L3, L4, and L5) of healthy volunteers. Sixteen healthy volunteers were examined at 1.5 T two times to obtain a repeated measurement in the same slice and a third time in three parallel slices. Single slice, two point Dixon SE (TR/TE 2,500/22.3) sequences were used, from which fat-fraction images were calculated. The fat-fraction results are presented as averages over regions of interest, which were derived from the contours of the vertebrae. Reproducibility measures related to repeated measurements on different days, slice position, and contour drawing were calculated. The mean fat fraction was 0.37 (SD 0.08). The SD due to repeated measurement was small (sigmaR = 0.013-0.032), almost all of which can be explained by slice-(re)-positioning errors. When used to evaluate the same person longitudinally in time, Dixon QCSI fat-fraction measurement has an excellent reproducibility. It is a powerful noninvasive tool in the evaluation of bone marrow composition.
Loy, S L; Marhazlina, M; Nor, Azwany Y; Hamid, Jan J M
2011-04-01
This study aimed to develop and examine the validity and reproducibility of a semi-quantitative food frequency questionnaire (FFQ) among Malay pregnant women in Kelantan, Malaysia. A total of 177 Malay pregnant women participated in the validation study while 85 of them participated in the reproducibility study which was carried out in the antenatal clinic of Universiti Sains Malaysia Hospital. The newly developed FFQ was validated against two 24-hour dietary recalls (DR). The FFQ was repeated 20 to 28 days apart. Results showed that the FFQ moderately over-estimated the nutrient and food intakes compared to the DR. Spearman correlation coefficients for nutrients ranged from 0.24 (fat) to 0.61 (calcium) and for foods, ranged from 0.13 (organ meats, onion and garlic) to 0.57 (malt drink). For nutrients, 72 to 85% of women were classified into the correct quartiles from the FFQ and the DR while for foods, 67 to 85% of women were classified correctly. Bland-Altman plot showed relatively good agreement between these two dietary methods. The intra-class correlation (ICC) was used to estimate reproducibility. It ranged from 0.75 (vitamin C) to 0.94 (phosphorus) for nutrients while it ranged from 0.73 (confectionary) to 0.96 (coffee) for foods. On average, at least 90% of pregnant women were correctly classified into the quartiles for nutrients and foods from the two sets of the FFQ. The FFQ presented acceptable reproducibility and appears to be a valid tool for categorising pregnant women according to dietary intake.
IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T
Cui, Yong; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Taouli, Bachir
2015-01-01
Purpose To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5 T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. Materials and methods In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5 T and 3.0 T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm2. A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b0, 200, 400 and 800 s/mm2. Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland–Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. Results The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values (p = 0.006–0.020), except for b0 (p = 0.239). Liver IVIM parameters were significantly different between 1.5 T and 3.0 T (p = 0.005–0.044), except for ADC (p = 0.748). The inter-platform reproducibility of true diffusion coefficient (D) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient (D*) showed more limited inter-platform reproducibility (mean CV of 22.6% for PF and 46.9% for D*). Conclusion Liver D and ADC values showed good reproducibility between 1.5 T and 3.0 T platforms; while there was more variability in PF, and large variability in D* parameters between the two platforms. These findings may have implications for drug trials assessing the role of IVIM DWI in tumor response and liver fibrosis. PMID:26393236
Padayachy, Llewellyn C; Padayachy, Vaishali; Galal, Ushma; Gray, Rebecca; Fieggen, A Graham
2016-10-01
The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children. ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study. Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97-0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3. Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP.
Thirumalraj, Balamurugan; Palanisamy, Selvakumar; Chen, Shen-Ming; Lou, Bih-Show
2016-01-15
The research community has continuously paid much attention on the preparation of hybrid of carbon nanomaterials owing to combine their unique properties. Herein, we report the preparation of highly stable fullerene C60 (C60) wrapped graphene oxide (GO) nanocomposite by using a simple sonication method. The fabricated GO-C60 nanocomposite modified glassy carbon electrode shows a good sensitivity and lower oxidation overpotential towards dopamine (DA) than that of pristine GO and C60. The fabricated sensor detects the DA in the linear response range of 0.02-73.5μM. The limit of detection is estimated to be 0.008μM based on 3σ with a sensitivity of 4.23μAμM(-1)cm(-2). The fabricated sensor also exhibits other features such as good selectivity, stability, reproducibility and repeatability. The proposed sensor exhibits good practicality towards the detection of DA in rat brain and commercial DA injection samples. Copyright © 2015 Elsevier Inc. All rights reserved.
Reproducible nucleation sites for flux dendrites in MgB 2
NASA Astrophysics Data System (ADS)
Johansen, T. H.; Shantsev, D. V.; Olsen, Å. A. F.; Roussel, M.; Pan, A. V.; Dou, S. X.
2007-12-01
Magneto-optical imaging was used to study dendritic flux penetration in films of MgB 2. By repeating experiments under the same external conditions, reproducible features were seen in the pattern formation; dendrites tend to nucleate from fixed locations along the edge. However, their detailed structure deeper inside the film is never reproduced. The reproducibility in nucleation sites is explained as a result of edge roughness causing field hot spots.
Capparelli, Ignacio; Fernandez, Martín; Saadia Otero, Marcela; Steimberg, Jimena; Brassesco, María; Campobasso, Ana; Palacios, Sandra; Caro, Fabian; Alberti, María Laura; Rabinovich, Roberto A; Paulin, Francisco
2018-02-01
Interstitial lung disease (ILD) is associated with low exercise tolerance, dyspnea, and decreased health-related quality of life (HRQL). Idiopathic pulmonary fibrosis (IPF) is one of the most prevalent in the group. A specific version of the Saint George's questionnaire (SGRQ-I) has been developed to quantify the HRQL of IPF patients. However, this tool is not currently validated in the Spanish language. The objective was to translate into Spanish and validate the specific Saint George's Respiratory Questionnaire for idiopathic pulmonary fibrosis (SGRQ-I). The repeatability, internal consistency and construct validity of the SGRQ-I in Spanish were analyzed after a backtranslation process. In total, 23 outpatients with IPF completed the translated SGRQ-I twice, 7 days apart. Repeatability was studied, revealing good concordance in test-retest with an ICC (interclass correlation coefficient) of 0.96 (P<.001). Internal consistency was good for different questionnaire items (Cronbach's alpha of 0.9 including and 0.81 excluding the total value) (P<.001). The total score of the questionnaire showed good correlation with forced vital capacity FVC% (r=-0.44; P=.033), diffusing capacity of the lungs for carbon monoxide (DL CO %) (r=-0.55; P=.011), partial pressure of oxygen in arterial blood PaO 2 (r=-0.44; P=.036), Medical Research Council Dyspnea scale (r=-0.65; P<.001), and number of steps taken in 24hours (r=-0.47; P=.024). The Spanish version of SGRQ-Ideveloped by our group shows good internal consistency, reproducibility and validity, so it can be used for the evaluation of quality of life (QOL) in IPF patients. Copyright © 2017 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.
Liu, Xiao-jing; Li, Qian-qian; Pang, Yuan-jie; Tian, Kai-yue; Xie, Zheng; Li, Zi-li
2015-06-01
As computer-assisted surgical design becomes increasingly popular in maxillofacial surgery, recording patients' natural head position (NHP) and reproducing it in the virtual environment are vital for preoperative design and postoperative evaluation. Our objective was to test the repeatability and accuracy of recording NHP using a multicamera system and a laser level. A laser level was used to project a horizontal reference line on a physical model, and a 3-dimensional image was obtained using a multicamera system. In surgical simulation software, the recorded NHP was reproduced in the virtual head position by registering the coordinate axes with the horizontal reference on both the frontal and lateral views. The repeatability and accuracy of the method were assessed using a gyroscopic procedure as the gold standard. The interclass correlation coefficients for pitch and roll were 0.982 (0.966, 0.991) and 0.995 (0.992, 0.998), respectively, indicating a high degree of repeatability. Regarding accuracy, the lack of agreement in orientation between the new method and the gold standard was within the ranges for pitch (-0.69°, 1.71°) and for roll (-0.92°, 1.20°); these have no clinical significance. This method of recording and reproducing NHP with a multicamera system and a laser level is repeatable, accurate, and clinically feasible. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Arnalich-Montiel, Francisco; Ortiz-Toquero, Sara; Auladell, Clara; Couceiro, Ana
2018-06-01
To assess intraobserver repeatability, intersession reproducibility, and agreement of swept-source Fourier-domain optical coherence tomography (SS-OCT) and the Scheimpflug camera in measuring corneal thickness in virgin and grafted eyes with Fuchs endothelial corneal dystrophy (FECD). Thirty-six control eyes, 35 FECD eyes, 30 FECD with corneal edema eyes, 25 Descemet stripping automated endothelial keratoplasty (DSAEK) eyes, and 29 Descemet membrane endothelial keratoplasty (DMEK) eyes were included. The apical center, pupillary center, and thinnest corneal thickness were determined in 3 consecutive images and repeated 2 weeks later. Repeatability and reproducibility coefficients, intraclass correlation coefficients, and 95% limits of agreement (LOA) between measurements were calculated. Agreement between devices was assessed using Bland-Altman analysis. Corneal thickness measurements were highly reproducible and repeatable with both systems. SS-OCT showed better repeatability in all corneal locations in the normal, FECD, FECD with edema, DSAEK, and DMEK groups (coefficient of variation ≤0.60%, ≤0.36%, ≤0.43%, ≤1.09%, and ≤0.48%, respectively) than the Scheimpflug (coefficient of variation ≤1.15%, ≤0.92%, ≤1.10%, ≤1.25%, and ≤1.14%, respectively). Between-session 95% LOA for SS-OCT was less than 3% for all groups except for the FECD with edema group, being almost double using the Scheimpflug camera. Differences between instruments were statistically significant in all groups and locations (P < 0.01) except in the DSAEK group (P ≤ 0.51); however, SS-OCT underestimated all measurements. SS-OCT provides better reproducible and repeatable measurements of corneal thickness than those obtained with the Scheimpflug camera in patients with FECD or an endothelial transplant. Variations between examinations higher than the 95% LOA observed in our study should raise awareness of changes in the endothelial function.
Forensic use of the Greulich and Pyle atlas: prediction intervals and relevance.
Chaumoitre, K; Saliba-Serre, B; Adalian, P; Signoli, M; Leonetti, G; Panuel, M
2017-03-01
The Greulich and Pyle (GP) atlas is one of the most frequently used methods of bone age (BA) estimation. Our aim is to assess its accuracy and to calculate the prediction intervals at 95% for forensic use. The study was conducted on a multi-ethnic sample of 2614 individuals (1423 boys and 1191 girls) referred to the university hospital of Marseille (France) for simple injuries. Hand radiographs were analysed using the GP atlas. Reliability of GP atlas and agreement between BA and chronological age (CA) were assessed and prediction intervals at 95% were calculated. The repeatability was excellent and the reproducibility was good. Pearson's linear correlation coefficient between CA and BA was 0.983. The mean difference between BA and CA was -0.18 years (boys) and 0.06 years (girls). The prediction interval at 95% for CA was given for each GP category and ranged between 1.2 and more than 4.5 years. The GP atlas is a reproducible and repeatable method that is still accurate for the present population, with a high correlation between BA and CA. The prediction intervals at 95% are wide, reflecting individual variability, and should be known when the method is used in forensic cases. • The GP atlas is still accurate at the present time. • There is a high correlation between bone age and chronological age. • Individual variability must be known when GP is used in forensic cases. • Prediction intervals (95%) are large; around 4 years after 10 year olds.
Use of autonomous maximal smile to evaluate dental and gingival exposure
Lin, Hengzhe; Yang, Yan; Zhao, Xin; Mei, Li; Zheng, Wei; Zhao, Zhihe
2018-01-01
Objective This study was performed to validate the autonomous maximal smile (AMS) as a new reference for evaluating dental and gingival exposure. Methods Digital video clips of 100 volunteers showing posed smiles and AMS at different verbal directives were recorded for evaluation a total of three times at 1-week intervals. Lip-teeth relationship width (LTRW) and buccal corridor width (BCW) were measured. LTRW represented the vertical distance between the inferior border of the upper vermilion and the edge of the maxillary central incisors. Intraclass correlation coefficients (ICCs) for reproducibility, and the m-value (minimum number of repeated measurements required for an ICC level over 0.75), were calculated. Results LTRW and BCW of the AMS were 1.41 and 2.04 mm, respectively, greater than those of the posed smile (p < 0.05), indicating significantly larger dental and gingival exposure in the AMS. The reproducibility of the AMS (0.74 to 0.77) was excellent, and higher than that of the posed smile (0.62 to 0.65), which had fair-to-good reproducibility. Moreover, the m-value of the AMS (0.88 to 1.05) was lower than that of the posed smile (1.59 to 1.85). Conclusions Compared to the posed smile, the AMS shows significantly larger LTRW and BCW, with significantly higher reproducibility. The AMS might serve as an adjunctive reference, in addition to the posed smile, in orthodontic and other dentomaxillofacial treatments. PMID:29732304
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yi-Xiang J., E-mail: yi-xiang.wang@astrazeneca.com; Kuribayashi, Hideto; Wagberg, Maria
Purpose. The Watanabe Heritable Hyperlipidemic (WHHL) rabbit provides an important model of spontaneous atherosclerosis. With a strain of WHHL rabbits which do not develop abdominal aorta lumen stenosis even with advanced atherosclerosis, we studied the MRI-histology correlation, and the natural progression of atherosclerosis in the abdominal aorta. In addition, intra-reader segmentation repeatability and scan-rescan reproducibility were assessed. Methods. Two batches of female WHHL rabbits were used. The first batch of 6 rabbits was scanned at 20 weeks old. A second batch of 17 rabbits was scanned at 50 weeks old and then randomly divided into two subgroups: 8 were killedmore » for histologic investigation; 9 were kept alive for follow-up, with repeat scanning a week later to assess scan-rescan reproducibility, and again at 73 weeks old to assess disease progression. MR images were acquired at 4.7 T using a chemical shift selective fat suppression gradient echo with a saturation band suppressing blood signal within the aortic lumen. Five slices per animal were acquired, centered around the renal artery region of the abdominal aorta, with in-plane resolution of 0.195 mm and slice thickness of 3 mm. Results. The coefficient of variation for intra-reader reproducibility for aortic wall thickness measurements was 2.5% for repeat segmentations of the same scans on the same day, but segmentations of these same scans made 8 months later showed a systematic change, suggesting that intra-reader bias as well as increased variability could compromise assessments made over time. Comparative analyses were therefore performed in one postprocessing session. The coefficient of variation for scan-rescan reproducibility for aortic wall thickness was 5.5% for nine pairs of scans acquired a week apart and segmented on the same day. Good MRI-histology correlation was obtained. The MRI-measured mean aortic wall thickness of animals at 20 weeks of age was 76% that of animals at 50 weeks of age (p < 0.001). There was a small increase in aortic wall thickness between 50 and 73 weeks of age, but this was not significant (p > 0.05). The corresponding differences in lumen cross-sectional areas at 20, 50, and 73 weeks of age were not significant. These results were consistent with in-house historical histology data on this strain of rabbits. Conclusions. High-resolution gradient echo MRI can follow disease progression in the WHHL rabbit spontaneous atherosclerosis disease model.« less
Sharma, Ashish; Oakley, Jonathan D.; Schiffman, Joyce C.; Budenz, Donald L.; Anderson, Douglas R.
2010-01-01
OBJECTIVE To evaluate a new automated analysis of optic disc images obtained by spectral domain optical coherence tomography (SD-OCT). Areas of the optic disc, cup, and neural rim in SD-OCT images were compared with these areas from stereoscopic photographs, to represent the current traditional optic nerve evaluation. The repeatability of measurements by each method was determined and compared. DESIGN Evaluation of diagnostic technology. PARTICIPANTS 119 healthy eyes, 23 eyes with glaucoma, and 7 suspect eyes METHODS Optic disc and cup margins were traced from stereoscopic photographs by three individuals independently. Optic disc margins and rim widths were determined automatically in SD-OCT. A subset of photographs was examined and traced a second time, and duplicate SD-OCT images were also analyzed. MAIN OUTCOME MEASUREMENTS Agreement among photograph readers, between duplicate readings, and between SD-OCT and photographs were quantified by the intraclass correlation coefficient (ICC), by the root mean square (RMS), and the standard deviation (SD) of the differences. RESULTS Optic disc areas tended to be slightly larger when judged in photographs than by SD-OCT, while cup areas were similar. Cup and optic disc areas showed good correlation (0.8) between average photographic reading and SD-OCT, but only fair correlation of rim areas (0.4). The SD-OCT was highly reproducible (ICC of 0.96 to 0.99). Each reader was also consistent with himself on duplicate readings of 21 photographs (ICC 0.80 to 0.88 for rim area, 0.95 to 0.98 for all other measurements), but reproducibility was not as good as SD-OCT. Measurements derived from SD-OCT did not differ from photographic readings more than the readings of photographs by different readers differed from each other. CONCLUSIONS Designation of the cup and optic disc boundaries by an automated analysis of SD-OCT was within the range of variable designations by different readers from color stereoscopic photographs, but use of different landmarks typically made the designation of the optic disc size somewhat smaller in the automated analysis. There was better repeatability among measurements from SD-OCT than from among readers of photographs. The repeatability of automated measurement of SD-OCT images is promising for use both in diagnosis and in monitoring of progression. PMID:21397334
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Y; Fuller, C; Mohamed, A
2015-06-15
Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However, few have questioned its measurement repeatability/reproducibility when applied. The purpose of this study was to determine the short-term measurement repeatability of apparent diffusion coefficient ADC, true diffusion coefficient D, pseudodiffusion coefficient D* and perfusion fraction f, in head and neck squamous cell carcinoma (HNSCC) primary tumors and metastatic nodes. Methods: Ten patients with known HNSCC were examined twice using echo-planar DW-MRI with 12 b values (0 to 800 s/mm2) 1hour to 24 hours apart before radiation treatment. All patients weremore » scanned with the customized radiation treatment immobilization devices to reduce motion artifacts and to improve image registration in repeat scans. Regions of interests were drawn in primary tumor and metastases node in each patient (Fig. 1). ADC and IVIM parameters D, D* and f were calculated by least squares data fitting. Short-term test–retest repeatability of ADC and IVIM parameters were assessed by measuring Bland–Altman limits of agreements (BA-LA). Results: Sixteen HNSCC lesions were assessed in 10 patients. Repeatability of perfusion-sensitive parameters, D* and f, in HNSCC lesions was poor (BA-LA: -144% to 88% and −57% to 96% for D* and f, respectively); a lesser extent was observed for the diffusion-sensitive parameters of ADC and D (BA-LA: −34% to 39% and −37% to 40%, for ADC and D, respectively) (Fig. 2). Conclusion: Poor repeatability of D*/f and good repeatability for ADC/D were observed in HNSCC primary tumors and metastatic nodes. Efforts should be made to improve the measurement repeatability of perfusion-sensitive IVIM parameters.« less
Herold, Ingeborg H F; Saporito, Salvatore; Bouwman, R Arthur; Houthuizen, Patrick; van Assen, Hans C; Mischi, Massimo; Korsten, Hendrikus H M
2016-01-05
The aim of this study is to investigate the inter and intra-rater reliability, repeatability, and reproducibility of pulmonary transit time (PTT) measurement in patients using contrast enhanced ultrasound (CEUS), as an indirect measure of preload and left ventricular function. Mean transit times (MTT) were measured by drawing a region of interest (ROI) in right and left cardiac ventricle in the CEUS loops. Acoustic intensity dilution curves were obtained from the ROIs. MTTs were calculated by applying model-based fitting on the dilution curves. PTT was calculated as the difference of the MTTs. Eight raters with different levels of experience measured the PTT (time moment 1) and repeated the measurement within a week (time moment 2). Reliability and agreement were assessed using intra-class correlations (ICC) and Bland-Altman analysis. Repeatability was tested by estimating the variance of means (ANOVA) of three injections in each patient at different doses. Reproducibility was tested by the ICC of the two time moments. Fifteen patients with heart failure were included. The mean PTT was 11.8 ± 3.1 s at time moment 1 and 11.7 ± 2.9 s at time moment 2. The inter-rater reliability for PTT was excellent (ICC = 0.94). The intra-rater reliability per rater was between 0.81-0.99. Bland-Altman analysis revealed a bias of 0.10 s within the rater groups. Reproducibility for PTT showed an ICC = 0.94 between the two time moments. ANOVA showed no significant difference between the means of the three different doses F = 0.048 (P = 0.95). The mean and standard deviation for PTT estimates at three different doses was 11.6 ± 3.3 s. PTT estimation using CEUS shows a high inter- and intra-rater reliability, repeatability at three different doses, and reproducibility by ROI drawing. This makes the minimally invasive PTT measurement using contrast echocardiography ready for clinical evaluation in patients with heart failure and for preload estimation.
First MRI application of an active breathing coordinator
NASA Astrophysics Data System (ADS)
Kaza, E.; Symonds-Tayler, R.; Collins, D. J.; McDonald, F.; McNair, H. A.; Scurr, E.; Koh, D.-M.; Leach, M. O.
2015-02-01
A commercial active breathing coordinator (ABC) device, employed to hold respiration at a specific level for a predefined duration, was successfully adapted for magnetic resonance imaging (MRI) use for the first time. Potential effects of the necessary modifications were assessed and taken into account. Automatic MR acquisition during ABC breath holding was achieved. The feasibility of MR-ABC thoracic and abdominal examinations together with the advantages of imaging in repeated ABC-controlled breath holds were demonstrated on healthy volunteers. Five lung cancer patients were imaged under MR-ABC, visually confirming the very good intra-session reproducibility of organ position in images acquired with the same patient positioning as used for computed tomography (CT). Using identical ABC settings, good MR-CT inter-modality registration was achieved. This demonstrates the value of ABC, since application of T1, T2 and diffusion weighted MR sequences provides a wider range of contrast mechanisms and additional diagnostic information compared to CT, thus improving radiotherapy treatment planning and assessment.
First MRI application of an active breathing coordinator.
Kaza, E; Symonds-Tayler, R; Collins, D J; McDonald, F; McNair, H A; Scurr, E; Koh, D-M; Leach, M O
2015-02-21
A commercial active breathing coordinator (ABC) device, employed to hold respiration at a specific level for a predefined duration, was successfully adapted for magnetic resonance imaging (MRI) use for the first time. Potential effects of the necessary modifications were assessed and taken into account. Automatic MR acquisition during ABC breath holding was achieved. The feasibility of MR-ABC thoracic and abdominal examinations together with the advantages of imaging in repeated ABC-controlled breath holds were demonstrated on healthy volunteers. Five lung cancer patients were imaged under MR-ABC, visually confirming the very good intra-session reproducibility of organ position in images acquired with the same patient positioning as used for computed tomography (CT). Using identical ABC settings, good MR-CT inter-modality registration was achieved. This demonstrates the value of ABC, since application of T1, T2 and diffusion weighted MR sequences provides a wider range of contrast mechanisms and additional diagnostic information compared to CT, thus improving radiotherapy treatment planning and assessment.
de Carvalho Bittencourt, Marcelo; Kohler, Chantal; Henard, Sandrine; Rabaud, Christian; Béné, Marie C; Faure, Gilbert C
2013-01-01
Quality assessment in flow cytometry cannot obey the same rules as those applicable to the measurement of chemical analytes. However, regular follow-up of known patients may provide a robust in-house control of cell subsets evaluation. Sequential blood samples assessed for 32 HIV patients over several years and showing good stability were retrospectively assessed to establish coefficient of variations of the percentages of CD3+, CD4+, CD8+ cells, and CD4+ absolute counts (ACs). Mean relative standard variations for the whole cohort were of 0.04, 0.14, 0.08, and 0.18 for CD3%, CD4%, CD8%, and CD4 ACs, respectively. In-house follow-up of regularly checked compliant patients is a good alternative to traditional and costly repeatability and reproducibility studies for the validation of routine flow cytometry. © 2013 International Clinical Cytometry Society. Copyright © 2013 International Clinical Cytometry Society.
de Carvalho Bittencourt, Marcelo; Kohler, Chantal; Henard, Sandrine; Rabaud, Christian; Béné, Marie C; Faure, Gilbert C
2013-07-08
Background. Quality assessment in flow cytometry cannot obey the same rules as those applicable to the measurement of chemical analytes. However, regular follow-up of known patients may provide a robust in-house control of cell subsets evaluation. Methods. Sequential blood samples assessed for 32 HIV patients over several years and showing good stability were retrospectively assessed to establish coefficient of variations of the percentages of CD3+, CD4+, CD8+ cells and CD4+ absolute counts. Results. Mean relative standard variations for the whole cohort were of 0.04, 0.14, 0.08 and 0.18 for CD3%, CD4% CD8% and CD4 absolute counts respectively. Discussion. In-house follow up of regularly checked compliant patients is a good alternative to traditional and costly repeatability and reproducibility studies for the validation of routine flow cytometry. © 2013 Clinical Cytometry Society. Copyright © 2013 Clinical Cytometry Society.
First MRI application of an active breathing coordinator
Kaza, E; Symonds-Tayler, R; Collins, D J; McDonald, F; McNair, H A; Scurr, E; Koh, D-M; Leach, M O
2015-01-01
Abstract A commercial active breathing coordinator (ABC) device, employed to hold respiration at a specific level for a predefined duration, was successfully adapted for magnetic resonance imaging (MRI) use for the first time. Potential effects of the necessary modifications were assessed and taken into account. Automatic MR acquisition during ABC breath holding was achieved. The feasibility of MR-ABC thoracic and abdominal examinations together with the advantages of imaging in repeated ABC-controlled breath holds were demonstrated on healthy volunteers. Five lung cancer patients were imaged under MR-ABC, visually confirming the very good intra-session reproducibility of organ position in images acquired with the same patient positioning as used for computed tomography (CT). Using identical ABC settings, good MR-CT inter-modality registration was achieved. This demonstrates the value of ABC, since application of T1, T2 and diffusion weighted MR sequences provides a wider range of contrast mechanisms and additional diagnostic information compared to CT, thus improving radiotherapy treatment planning and assessment. PMID:25633183
On the reproducibility of expert-operated and robotic ultrasound acquisitions.
Kojcev, Risto; Khakzar, Ashkan; Fuerst, Bernhard; Zettinig, Oliver; Fahkry, Carole; DeJong, Robert; Richmon, Jeremy; Taylor, Russell; Sinibaldi, Edoardo; Navab, Nassir
2017-06-01
We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging. Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface. After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements. A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.
Vonk Noordegraaf, A; Kunst, P W; Janse, A; Smulders, R A; Heethaar, R M; Postmus, P E; Faes, T J; de Vries, P M
1997-03-01
The Sheffield electrical impedance tomography; (EIT) system produces images of changes in the distribution of resistivity within tissue. The paper reports on the application of electrical impedance tomography in monitoring volume changes in the limb during venous occlusion. The aim of the study is to assess the feasibility, reproducibility and validity of calf blood flow measurements by EIT. In 14 healthy volunteers calf blood flow is compared, as determined in a calf segment by strain-gauge plethysmography (SGP), with the impedance changes measured by EIT during rest and post-ischaemic hyperaemia. The measurements are repeated to assess reproducibility. The reproducibility for the EIT, assessed from the repeated measurements and expressed as a reproducibility coefficient, is 0.88 during rest and 0.89 during hyperaemia. The reproducibility coefficient for SGP data is 0.83 at rest and 0.67 during hyperaemia. Flow measurements, assessed by means of two methods, correlate well at rest (r = 0.89), but only moderately during hyperaemia (r = 0.51). The correlation coefficient for the pooled flow measurements is 0.98. It is concluded that EIT is a valid and reliable method for assessing blood flow in the limb. Possible applications of EIT in localising fluid changes are discussed.
Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N
2013-06-01
This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Zhang, Shuaihua; Yang, Qian; Li, Zhi; Wang, Wenjin; Zang, Xiaohuan; Wang, Chun; Wang, Zhi
2018-10-15
A hybrid composite featuring an iron-based metal-organic framework Material of Institute Lavoisier-88(Fe) and graphene oxide (MIL-88(Fe)/GO) was synthesized and used as the solid-phase microextraction (SPME) coating. The SPME fiber was prepared by covalent bonding of the MIL-88(Fe)/GO composite onto the stainless steel substrate. The fiber had a good durability and allowed >100 replicate extractions. The developed method, which combined the MIL-88(Fe)/GO coated fiber based SPME with gas chromatography-flame ionization detection (GC-FID), achieved low limits of detection (0.5-2.0 ng g -1 , S/N = 3) and good linearity (r 2 > 0.994) for the phthalic acid esters (PAEs) from various vegetable oil samples. The repeatability and fiber-to-fiber reproducibility were in the range of 4.0-9.1% and 5.7-11.4%, respectively. The method was successfully applied to the analysis of PAEs from vegetable oil samples with good recoveries (83.1-104.1%) and satisfactory precisions (RSDs < 10.5%), indicating that the MIL-88(Fe)/GO hybrid composite is a good coating material for the SPME of PAEs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bussey, C T; Leeuw, A E de; Cook, R F; Ashley, Z; Schofield, J; Lamberts, R R
2014-07-01
Expansion of physiological knowledge increasingly requires examination of processes in the normal, conscious state. The current study describes a novel approach combining surgical implantation of radio-telemeters with vascular access ports (VAPs) to allow repeated hemodynamic and pharmacological measures in conscious rats. Dual implantation was conducted on 16-week-old male lean and obese Zucker rats. Continued viability one month after surgery was observed in 67% of lean and 44% of obese animals, giving an overall 54% completion rate. Over the five-week measurement period, reliable and reproducible basal mean arterial pressure and heart rate measures were observed. VAP patency and receptor-independent vascular reactivity were confirmed by consistent hemodynamic responses to sodium nitroprusside (6.25 µg/kg). Acutely, minimal hemodynamic responses to repeated bolus administration of 0.2 mL saline indicated no significant effect of increased blood volume or administration stress, making repeated acute measures viable. Similarly, repeated administration of the β-adrenoceptor agonist dobutamine (30 µg/kg) at 10 min intervals resulted in reproducible hemodynamic changes in both lean and obese animals. Therefore, our study demonstrates that this new approach is viable for the acute and chronic assessment of hemodynamic and pharmacological responses in both lean and obese conscious rats. This technique reduces the demand for animal numbers and allows hemodynamic measures with minimal disruption to animals' welfare, while providing reliable and reproducible results over several weeks. In conclusion, dual implantation of a radio-telemeter and VAP introduces a valuable technique for undertaking comprehensive studies involving repeated pharmacological tests in conscious animals to address important physiological questions. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Clinical validation of robot simulation of toothbrushing - comparative plaque removal efficacy
2014-01-01
Background Clinical validation of laboratory toothbrushing tests has important advantages. It was, therefore, the aim to demonstrate correlation of tooth cleaning efficiency of a new robot brushing simulation technique with clinical plaque removal. Methods Clinical programme: 27 subjects received dental cleaning prior to 3-day-plaque-regrowth-interval. Plaque was stained, photographically documented and scored using planimetrical index. Subjects brushed teeth 33–47 with three techniques (horizontal, rotating, vertical), each for 20s buccally and for 20s orally in 3 consecutive intervals. The force was calibrated, the brushing technique was video supported. Two different brushes were randomly assigned to the subject. Robot programme: Clinical brushing programmes were transfered to a 6-axis-robot. Artificial teeth 33–47 were covered with plaque-simulating substrate. All brushing techniques were repeated 7 times, results were scored according to clinical planimetry. All data underwent statistical analysis by t-test, U-test and multivariate analysis. Results The individual clinical cleaning patterns are well reproduced by the robot programmes. Differences in plaque removal are statistically significant for the two brushes, reproduced in clinical and robot data. Multivariate analysis confirms the higher cleaning efficiency for anterior teeth and for the buccal sites. Conclusions The robot tooth brushing simulation programme showed good correlation with clinically standardized tooth brushing. This new robot brushing simulation programme can be used for rapid, reproducible laboratory testing of tooth cleaning. PMID:24996973
Clinical validation of robot simulation of toothbrushing--comparative plaque removal efficacy.
Lang, Tomas; Staufer, Sebastian; Jennes, Barbara; Gaengler, Peter
2014-07-04
Clinical validation of laboratory toothbrushing tests has important advantages. It was, therefore, the aim to demonstrate correlation of tooth cleaning efficiency of a new robot brushing simulation technique with clinical plaque removal. Clinical programme: 27 subjects received dental cleaning prior to 3-day-plaque-regrowth-interval. Plaque was stained, photographically documented and scored using planimetrical index. Subjects brushed teeth 33-47 with three techniques (horizontal, rotating, vertical), each for 20s buccally and for 20s orally in 3 consecutive intervals. The force was calibrated, the brushing technique was video supported. Two different brushes were randomly assigned to the subject. Robot programme: Clinical brushing programmes were transfered to a 6-axis-robot. Artificial teeth 33-47 were covered with plaque-simulating substrate. All brushing techniques were repeated 7 times, results were scored according to clinical planimetry. All data underwent statistical analysis by t-test, U-test and multivariate analysis. The individual clinical cleaning patterns are well reproduced by the robot programmes. Differences in plaque removal are statistically significant for the two brushes, reproduced in clinical and robot data. Multivariate analysis confirms the higher cleaning efficiency for anterior teeth and for the buccal sites. The robot tooth brushing simulation programme showed good correlation with clinically standardized tooth brushing.This new robot brushing simulation programme can be used for rapid, reproducible laboratory testing of tooth cleaning.
Gravesen, F H; Gregersen, H; Arendt-Nielsen, L; Drewes, A M
2010-02-01
Manometry is the golden standard to diagnose oesophageal motility disorders but it gives an indirect picture of the peristalsis by measuring radial force only. A novel probe design using electrical impedance recordings enabled axial force and manometry to be recorded simultaneously. Using this method the aims were to study the amplitude and duration of peristaltic contractions, to test the correlation between axial force and manometry, and the reproducibility of the method. Ten healthy men were included twice. The probe was positioned 5 cm proximal to the lower oesophageal sphincter after which five dry swallows and five wet swallows were done. This was repeated with 0, 2, 4 and 6 mL of water in a bag mounted distal to the axial force recording site. Duration and amplitude of contractions were measured by axial force and manometry. Both increased with the bag volume (P < 0.05), with force measurements having approximately twice the dynamic range than manometry (P < 0.05). Contraction duration and amplitude showed good reproducibility for both axial force and manometry (interclass correlation coefficients >0.6). The best association between axial force and manometry was found during wet swallows with an empty bag (r = 0.72, P < 0.001), otherwise these measurements were not associated. The system provided a more complete description of primary oesophageal peristalsis. Axial force and manometry were both reproducible but force measurements had increased dynamic range. As manometry and axial force generally are not associated, they each provide different information, and in combination they may be useful to better characterize oesophageal motor function.
Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo
2015-01-01
To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.
NASA Technical Reports Server (NTRS)
Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.
2010-01-01
Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.
Olsen, Rasmus Huan; Pedersen, Lene Rørholm; Snoer, Martin; Christensen, Thomas Emil; Ghotbi, Adam Ali; Hasbak, Philip; Kjaer, Andreas; Haugaard, Steen B; Prescott, Eva
2016-06-07
Coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography of the LAD is used to assess microvascular function but validation studies in clinical settings are lacking. We aimed to assess feasibility, reproducibility and agreement with myocardial flow reserve (MFR) measured by PET in overweight and obese patients. Participants with revascularized coronary artery disease were examined by CFVR. Subgroups were examined by repeated CFVR (reproducibility) or Rubidium-82-PET (agreement). To account for time variation, results were computed for scans performed within a week (1-week) and for all scans regardless of time gap (total) and to account for scar tissue for patients with and without previous myocardial infarction (MI). Eighty-six patients with median BMI 30.9 (IQR 29.4-32.9) kg × m(-2) and CFVR 2.29 (1.90-2.63) were included. CFVR was feasible in 83 (97 %) using a contrast agent in 14 %. For reproducibility overall (n = 21) limits of agreement (LOA) were (-0.75;0.71), within-subjects coefficient of variation (CV) 11 %, and reliability 0.84. For reproducibility within 1-week (n = 13) LOA were (-0.33;0.25), within-subjects CV 5 %, and reliability 0.97. Agreement with MFR of the LAD territory (n = 35) was without significant bias and overall LOA were (-1.40;1.46). Agreement was best for examinations performed within 1-week of participants without MI of the LAD-territory (n = 12); LOA = (-0.68;0.88). CFVR was highly feasible with a good reproducibility on par with other contemporary measures applied in cardiology. Agreement with MFR was acceptable, though discrepancy related to prior MI has to be considered. CFVR of LAD is a valid tool in overweight and obese patients.
After two previous investigations demonstrated that the Baffled Flask Test (BFT) was an effective and reproducible method for screening the effectiveness of dispersant products in the laboratory, the USEPA decided that before the new protocol cold be considered for replacement of...
In vivo studies provide reference data to evaluate alternative methods for predicting toxicity. However, the reproducibility and variance of effects observed across multiple in vivo studies is not well understood. The US EPA’s Toxicity Reference Database (ToxRefDB) stores d...
de Freitas, Roseli Santos; Kamikawa, Camila Mika; Vicentini, Adriana Pardini
Current methods for the production of Histoplasma capsulatum antigens are problematic in terms of standardization, specificity, stability, repeatability and reproducibility. In this study, we sought to optimize the methodology for producing H. capsulatum antigens, and to evaluate its applicability. Antigenic preparations obtained from 12 H. capsulatum isolates were evaluated by double immunodiffusion and immunoblotting assays against homologous and heterologous sera. The evaluated and optimized protocol allowed a more stable production, as well as repeatable, reproducible, with shorter culture time and less costly. By double immunodiffusion and immunoblotting assays, the best pattern of reactivity was observed for antigens obtained with 33 days of culture from the isolates 200 and 406 against the M antigen and for the isolate 200 with 15 days against H antigen. The SDS-PAGE presented antigenic components of molecular masses between 17 and 119kDa. The immunoblotting sensitivity was 95.5% and 100% with histoplasmosis sera from ill patients and sera from H. capsulatum infected but otherwise healthy patients, respectively, to the antigen derived from isolates 200 and 406. We suggest the employment of the antigen from isolate 200, with 15 or 30 days of culture, in the double immunodiffusion and immunoblotting assays due to its good ability to discriminate both sera from patients with histoplasmosis illness and histoplasmosis infection, in addition to its high specificity against heterologous sera. Copyright © 2017 Asociación Española de Micología. Publicado por Elsevier España, S.L.U. All rights reserved.
[Determination of 27 elements in Maca nationality's medicine by microwave digestion ICP-MS].
Yu, Gui-fang; Zhong, Hai-jie; Hu, Jun-hua; Wang, Jing; Huang, Wen-zhe; Wang, Zhen-zhong; Xiao, Wei
2015-12-01
An analysis method has been established to test 27 elements (Li, Be, B, Mg, Al, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Sr, Mo, Cd, Sn, Sb, Ba, La, Hg, Pb, Bi) in Maca nationality's medicine with microwave digestion-ICP-MS. Sample solutions were analyzed by ICP-MS after microwave digestion, and the contents of elements were calculated according to their calibration curves, and internal standard method was adopted to reduce matrix effect and other interference effects. The experimental results showed that the linear relations of all the elements were very good; the correlation coefficient (r) was 0.9994-1.0000 (Hg was 0.9982) ; the limits of detection were 0.003-2.662 microg x L(-1); the relative standard deviations for all elements of reproducibility were lower than 5% (except the individual elements); the recovery rate were 78.5%-123.7% with RSD lower than 5% ( except the individual elements). The analytical results of standard material showed acceptable agreement with the certified values. This method was applicable to determinate the contents of multi-elements in Maca which had a high sensitivity, good specificity and good repeatability, and provide basis for the quality control of Maca.
NASA Astrophysics Data System (ADS)
Ito, Shunya; Kasuya, Motohiro; Kurihara, Kazue; Nakagawa, Masaru
2018-02-01
We measured the surface forces generated between fused silica surfaces in a low-viscosity oleophilic diacrylate monomer for reliably repeated ultraviolet (UV) nanoimprinting, and studied the influence of water in monomer liquids on the forces. Fused silica surfaces, with a static contact angle of 52.6 ± 1.7° for water, owing to the low degree of hydroxylation, hardly showed reproducible surface forces with repeated scan cycles, comprising approach and separation, even in an identical liquid monomer medium with both of low and high water content. The monomer liquid with a high water content of approximately 420 ppm showed a greater tendency to increase the surface forces at longer surface-surface distances compared with the monomer liquid with a low water content of approximately 60 ppm. On the other hand, silica surfaces with a water contact angle of < 5° after exposure to vacuum UV (VUV) light under a reduced air pressure showed reproducible profiles of surfaces forces using the monomer with a low water concentration of approximately 60 ppm for repeated surface forces scan cycles even in separately prepared silica surfaces, whilst they showed less reproducible profiles in the liquids with high water content of 430 ppm. These results suggested that water possibly adsorbed on the hydrophilic and hydrophobic silica surfaces in the monomer liquid of the high water concentration influenced the repeatability of the surface forces profiles.
van der Palen, Roel L F; Roest, Arno A W; van den Boogaard, Pieter J; de Roos, Albert; Blom, Nico A; Westenberg, Jos J M
2018-05-26
The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.
Collins, A L; Saunders, S; McCarthy, H D; Williams, J E; Fuller, N J
2004-01-01
To determine and compare the extent of within- and between-laboratory precision in body volume (BV) measurements using air displacement plethysmography (ADP), the BOD POD body composition system, and to interpret any such variability in terms of body composition estimates. Repeated test procedures of BV assessment using the BOD POD ADP were reproduced at two laboratories for the estimation of precision, both within and between laboratories. In total, 30 healthy adult volunteers, 14 men (age, 19-48 y; body mass index (BMI), 19.7-30.3 kg/m2) and 16 women (age, 19-40 y; BMI, 16.3-35.7 kg/m2), were each subjected to two test procedures at both laboratories. Two additional volunteers were independently subjected to 10 repeated test procedures at both laboratories. Repeated measurements of BV, uncorrected for the effects of isothermal air in the lungs and the surface area artifact, were obtained using the BOD POD ADP, with the identical protocol being faithfully applied at both laboratories. Uncorrected BV measurements were adjusted to give estimates of actual BV that were used to calculate body density (body weight (BWt)/actual BV) from which estimates of body composition were derived. The differences between repeated BV measurements or body composition estimates were used to assess within-laboratory precision (repeatability), as standard deviation (SD) and coefficient of variation; the differences between measurements reproduced at each laboratory were used to determine between-laboratory precision (reproducibility), as bias and 95% limits of agreement (from SD of the differences between laboratories). The extent of within-laboratory methodological precision for BV (uncorrected and actual) was variable according to subject, sample group and laboratory conditions (range of SD, 0.04-0.13 l), and was mostly due to within-individual biological variability (typically 78-99%) rather than to technical imprecision. There was a significant (P<0.05) bias between laboratories for the 10 repeats on the two independent subjects (up to 0.29 l). Although no significant bias (P=0.077) was evident for the sample group of 30 volunteers (-0.05 l), the 95% limits of agreement were considerable (-0.68 to 0.58 l). The effects of this variability in BV on body composition were relatively greater: for example, within-laboratory precision (SD) for body fat as % BWt was between 0.56 and 1.34% depending on the subject and laboratory; the bias (-0.59%) was not significant between laboratories, but there were large 95% limits of agreement (-3.67 to 2.50%). Within-laboratory precision for each BOD POD instrument was reasonably good, but was variable according to the prevailing conditions. Although the bias between the two instruments was not significant for the BV measurements, implying that they can be used interchangeably for groups of similar subjects, the relatively large 95% limits of agreement indicate that greater consideration may be needed for assessing individuals with different ADP instruments. Therefore, use of a single ADP instrument is apparently preferable when assessing individuals on a longitudinal basis.
Giannotti, E; Waugh, S; Priba, L; Davis, Z; Crowe, E; Vinnicombe, S
2015-09-01
Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan-scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26-61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29-70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADCS) and the ADC value of a small region of interest (ROI) on the same slice (ADCmin). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Scanner stability contributed 6% error to phantom ADC measurements (0.071×10(-3)mm(2)/s; mean ADC=1.089×10(-3)mm(2)/s). The measured scan-scan CoR in the volunteers was 0.122×10(-3)mm(2)/s, contributing an error of 8% to the mean measured values (ADCscan1=1.529×10(-3)mm(2)/s; ADCscan2=1.507×10(-3)mm(2)/s). Technical and clinical observers demonstrated excellent intra-observer repeatability (ICC>0.9). Clinical observer CoR values were marginally better than technical observer measures (ADCS=0.035×10(-3)mm(2)/s vs. 0.097×10(-3)mm(2)/s; ADCmin=0.09×10(-3)mm(2)/s vs. 0.114×10(-3)mm(2)/s). Inter-reader ICC values were good 0.864 (ADCS) and fair 0.677 (ADCmin). Corresponding CoR values were 0.202×10(-3)mm(2)/s and 0.264×10(-3)mm(2)/s, respectively. Both scanner stability and scan-scan variation have minimal influence on breast ADC measurements, contributing less than 10% error of average measured ADC values. Measurement of ADC values from a small ROI contributes a greater variability in measurements compared with measurement of ADC across the whole visible tumor on one slice. The greatest source of error in follow-up studies is likely to be associated with measures made by multiple observers, and this should be considered where multiple measures are required to assess response to treatment. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Abd Rashid, Amirul; Hayati Saad, Nor; Bien Chia Sheng, Daniel; Yee, Lee Wai
2014-06-01
PH value is one of the important variables for tungsten trioxide (WO3) nanostructure hydrothermal synthesis process. The morphology of the synthesized nanostructure can be properly controlled by measuring and controlling the pH value of the solution used in this facile synthesis route. Therefore, it is very crucial to ensure the gauge used for pH measurement is reliable in order to achieve the expected result. In this study, gauge repeatability and reproducibility (GR&R) method was used to assess the repeatability and reproducibility of the pH tester. Based on ANOVA method, the design of experimental metrics as well as the result of the experiment was analyzed using Minitab software. It was found that the initial GR&R value for the tester was at 17.55 % which considered as acceptable. To further improve the GR&R level, a new pH measuring procedure was introduced. With the new procedure, the GR&R value was able to be reduced to 2.05%, which means the tester is statistically very ideal to measure the pH of the solution prepared for WO3 hydrothermal synthesis process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Y.Z., E-mail: singyuanzhi@sina.com; Zhou, J.F.; Song, Y., E-mail: songyang@mail.buct.edu.cn
Graphical abstract: Electrochemical deposition of netlike gold nanoparticles (GNPs) on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The catalytic properties of netlike gold nanoparticles on the glassy carbon electrode for dopamine were demonstrated. The results indicate that the netlike gold nanoparticle modified electrode has an excellent repeatability and reproducibility. Display Omitted Highlights: ► Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent. ► Excellent repeatability and reproducibility of netlike gold nanoparticle modified glassy carbon electrode. ► The catalytic properties of netlike gold nanoparticlemore » for dopamine. -- Abstract: Electrochemical deposition of netlike gold nanoparticles on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The netlike gold nanoparticles were characterized by scanning electron microscope, transmission electron microscope, infrared spectrometer, UV spectrophotometer, powder X-ray diffractometer and electrochemical analyzer. The catalysis of the netlike gold nanoparticles on the glassy carbon electrode for dopamine was demonstrated. The results indicate that the gold nanoparticle modified electrode has an excellent repeatability and reproducibility.« less
de Oliveira, Anapolino Macedo; Fonseca, Antônio Augusto; Camargos, Marcelo Fernandes; Orzil, Lívia Maria; Laguardia-Nascimento, Mateus; Oliveira, Anna Gabriella Guimarães; Rodrigues, Jacqueline Gomes; Sales, Mariana Lázaro; de Oliveira, Tatiana Flávia Pinheiro; de Melo, Cristiano Barros
2018-07-01
Vesicular stomatitis is an infectious disease that occurs mainly in countries of the Western Hemisphere and affects cattle, swine and horses. The clinical symptoms in cattle and swine are similar to foot-and-mouth disease and include vesicular ulceration of the tongue and mouth. The disease requires a rapid and accurate differential diagnosis, aiming for immediate implementation of control measures. The objective of the present study was to develop and perform validation tests of multiplex RT-qPCR(s) for the detection of RNA from Alagoas vesiculovirus, considering the parameters of sensitivity and analytical specificity, analytical performance (repeatability and reproducibility criteria) and the uncertainty of the measurement. The threshold cycle values obtained in triplicate from each sample were evaluated by considering the variations between days, analysts and equipment in an analysis of variance aimed at determining the variances of repeatability and reproducibility. The results showed that RT-qPCRs had excellent sensitivity and specificity in the detection of RNA of the Alagoas vesiculovirus. The validation parameters showed low coefficients of variation and were equivalent to those found in other validation studies, indicating that the tests presented excellent repeatability and reproducibility. Copyright © 2018 Elsevier B.V. All rights reserved.
Weigel, Stefan; Peters, Ruud; Loeschner, Katrin; Grombe, Ringo; Linsinger, Thomas P J
2017-08-01
Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) promises fast and selective determination of nanoparticle size and number concentrations. While several studies on practical applications have been published, data on formal, especially interlaboratory validation of sp-ICP-MS, is sparse. An international interlaboratory study was organized to determine repeatability and reproducibility of the determination of the median particle size and particle number concentration of Ag nanoparticles (AgNPs) in chicken meat. Ten laboratories from the European Union, the USA, and Canada determined particle size and particle number concentration of two chicken meat homogenates spiked with polyvinylpyrrolidone (PVP)-stabilized AgNPs. For the determination of the median particle diameter, repeatability standard deviations of 2 and 5% were determined, and reproducibility standard deviations were 15 and 25%, respectively. The equivalent median diameter itself was approximately 60% larger than the diameter of the particles in the spiking solution. Determination of the particle number concentration was significantly less precise, with repeatability standard deviations of 7 and 18% and reproducibility standard deviations of 70 and 90%.
Krishnamurthy, Gerbail T; Krishnamurthy, Shakuntala; Gambhir, Sanjiv Sam; Rodrigues, Cesar; Rosenberg, Jarrett; Schiepers, Christiaan; Buxton-Thomas, Muriel
2009-12-01
To develop a software tool for quantification of liver and gallbladder function, and to assess the repeatability and reproducibility of measurements made with it. The software tool developed with the JAVA programming language uses the JAVA2 Standard Edition framework. After manual selection of the regions of interest on a 99mTc hepatic iminodiacetic acid study, the program calculates differential hepatic bile flow, basal duodeno-gastric bile reflux (B-DGBR), hepatic extraction fraction (HEF) of both the lobes with deconvolutional analysis and excretion half-time with nonlinear least squares fit. Gallbladder ejection fraction, ejection period (EP), ejection rate (ER), and postcholecystokinin (CCK) DGBR are calculated after stimulation with CCK-8. To assess intra-observer repeatability and intra-observer reproducibility, measurements from 10 normal participants were analyzed twice by three nuclear medicine technologists at the primary center. To assess inter-site reproducibility, measurements from a superset of 24 normal participants were also assessed once by three observers at the primary center and single observer at three other sites. For the 24 control participants, mean+/-SD of hepatic bile flow into gallbladder was 63.87+/-28.7%, HEF of the right lobe 100+/-0%, left lobe 99.43+2.63%, excretion half-time of the right lobe 21.50+6.98 min, left lobe 28.3+/-11.3 min. Basal DGBR was 1.2+/-1.0%. Gallbladder ejection fraction was 80+/-11%, EP 15.0+/-3.0 min, ER 5.8+/-1.6%/min, and DGBR-CCK 1.3+/-2.3%. Left and right lobe HEF was virtually identical across readers. All measures showed high repeatability except for gallbladder bile flow, basal DGBR, and EP, which exhibited marginal repeatability. Ejection fraction exhibited high reproducibility. There was high concordance among the three primary center observers except for basal DGBR, EP, and ER. Concordance between the primary site and one of the other sites was high, one was fair, and one was poor. New United States Food and Drug Administration-approved personal computer-based Krishnamurthy Hepato-Biliary Software for quantification of the liver and gallbladder function shows promise for consistently repeatable and reproducible results both within and between institutions, and may help to promote universal standardization of data acquisition and analysis in nuclear hepatology.
Finding reproducible cluster partitions for the k-means algorithm
2013-01-01
K-means clustering is widely used for exploratory data analysis. While its dependence on initialisation is well-known, it is common practice to assume that the partition with lowest sum-of-squares (SSQ) total i.e. within cluster variance, is both reproducible under repeated initialisations and also the closest that k-means can provide to true structure, when applied to synthetic data. We show that this is generally the case for small numbers of clusters, but for values of k that are still of theoretical and practical interest, similar values of SSQ can correspond to markedly different cluster partitions. This paper extends stability measures previously presented in the context of finding optimal values of cluster number, into a component of a 2-d map of the local minima found by the k-means algorithm, from which not only can values of k be identified for further analysis but, more importantly, it is made clear whether the best SSQ is a suitable solution or whether obtaining a consistently good partition requires further application of the stability index. The proposed method is illustrated by application to five synthetic datasets replicating a real world breast cancer dataset with varying data density, and a large bioinformatics dataset. PMID:23369085
Finding reproducible cluster partitions for the k-means algorithm.
Lisboa, Paulo J G; Etchells, Terence A; Jarman, Ian H; Chambers, Simon J
2013-01-01
K-means clustering is widely used for exploratory data analysis. While its dependence on initialisation is well-known, it is common practice to assume that the partition with lowest sum-of-squares (SSQ) total i.e. within cluster variance, is both reproducible under repeated initialisations and also the closest that k-means can provide to true structure, when applied to synthetic data. We show that this is generally the case for small numbers of clusters, but for values of k that are still of theoretical and practical interest, similar values of SSQ can correspond to markedly different cluster partitions. This paper extends stability measures previously presented in the context of finding optimal values of cluster number, into a component of a 2-d map of the local minima found by the k-means algorithm, from which not only can values of k be identified for further analysis but, more importantly, it is made clear whether the best SSQ is a suitable solution or whether obtaining a consistently good partition requires further application of the stability index. The proposed method is illustrated by application to five synthetic datasets replicating a real world breast cancer dataset with varying data density, and a large bioinformatics dataset.
Hu, B; Wang, Y; Zealey, W
2009-12-01
A commercial Optical Stimulated Luminescence (OSL) dosimetry system developed by Landauer was tested to analyse the possibility of using OSL dosimetry for external beam radiotherapy planning checks. Experiments were performed to determine signal sensitivity, dose response range, beam type/energy dependency, reproducibility and linearity. Optical annealing processes to test OSL material reusability were also studied. In each case the measurements were converted into absorbed dose. The experimental results show that OSL dosimetry provides a wide dose response range, good linearity and reproducibility for the doses up to 800cGy. The OSL output is linear with dose up to 600cGy range showing a maximum deviation from linearity of 2.0% for the doses above 600cGy. The standard deviation in response of 20 dosimeters was 3.0%. After optical annealing using incandescent light, the readout intensity decreased by approximately 98% in the first 30 minutes. The readout intensity, I, decreased after repeated optical annealing as a power law, given by I infinity t (-1.3). This study concludes that OSL dosimetry can provide an alternative dosimetry technique for use in in-vivo dosimetry if rigorous measurement protocols are established.
Simón-Manso, Yamil; Lowenthal, Mark S; Kilpatrick, Lisa E; Sampson, Maureen L; Telu, Kelly H; Rudnick, Paul A; Mallard, W Gary; Bearden, Daniel W; Schock, Tracey B; Tchekhovskoi, Dmitrii V; Blonder, Niksa; Yan, Xinjian; Liang, Yuxue; Zheng, Yufang; Wallace, William E; Neta, Pedatsur; Phinney, Karen W; Remaley, Alan T; Stein, Stephen E
2013-12-17
Recent progress in metabolomics and the development of increasingly sensitive analytical techniques have renewed interest in global profiling, i.e., semiquantitative monitoring of all chemical constituents of biological fluids. In this work, we have performed global profiling of NIST SRM 1950, "Metabolites in Human Plasma", using GC-MS, LC-MS, and NMR. Metabolome coverage, difficulties, and reproducibility of the experiments on each platform are discussed. A total of 353 metabolites have been identified in this material. GC-MS provides 65 unique identifications, and most of the identifications from NMR overlap with the LC-MS identifications, except for some small sugars that are not directly found by LC-MS. Also, repeatability and intermediate precision analyses show that the SRM 1950 profiling is reproducible enough to consider this material as a good choice to distinguish between analytical and biological variability. Clinical laboratory data shows that most results are within the reference ranges for each assay. In-house computational tools have been developed or modified for MS data processing and interactive web display. All data and programs are freely available online at http://peptide.nist.gov/ and http://srmd.nist.gov/ .
Ara, Mirian; Pajarin, Ana B.
2015-01-01
Objective. To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. Methods. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. Results. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. Conclusions. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression. PMID:26185762
Reproducibility of the retinal vascular response to flicker light in Asians.
Nguyen, Thanh T; Kreis, Andreas J; Kawasaki, Ryo; Wang, Jie Jin; Seifert, Bernd-U; Vilser, Walthard; Nagel, Edgar; Wong, Tien Y
2009-12-01
Dilation of retinal vessels in response to diffuse luminance flicker may reflect endothelial function. Although this has previously been shown to be reproducible in whites, there have been no similar data in Asians. We assess the reproducibility of repeated measurements of this response in Asians. Healthy Asians (n = 33) with normal vision and no history of glaucoma, age-related macular degeneration, cataract, or retinal arterial/venous occlusion participated in this study. Repeated measures from the same subjects were taken 30-60 min apart using the Dynamic Vessel Analyser (DVA, IMEDOS, Jena, Germany). Modification was made to the shape of the light source for Asian participants. Correlations of the first and second measures were assessed using Pearson correlation (R(2)), and agreement between the two measures was shown using Bland-Altman plots. After modification to the shape of the light source, almost perfect correlation was found between the 1st and 2nd measurements of baseline arteriolar (R(2) = 0.95) and venular diameters (R(2) = 0.98) of arteriolar maximum dilation (R(2) = 0.85). Substantially high correlation between the 1st and 2nd measurements of venular maximum dilation was found (R(2) = 0.80). Measurements of the dilation response of retinal vessels to diffuse luminance flicker an Asian sample using the DVA show high reproducibility for repeated measures over a short period of time. Such measurements may allow non-invasive quantification of endothelial function to study its association with systemic and ocular diseases.
Social phobia: research and clinical practice.
Alnaes, R
2001-01-01
Social phobia is a pervasive pattern of social inhibition, feelings of inadequacy, and hypersensitivity, occurring in about 18% of the clinical population. Despite good results with cognitive-behavioural treatment, social phobia seems to be a chronic disorder with several complications. The author describes an analysis of a divorced woman who was exposed to an early premature sexual seduction by her father, abruptly terminated because of an accident. The loss of the father was repaired by a delusional system as defence against the re-emergence of a catastrophic situation. Her compulsion to repeat the traumatic situation was seen in symbolic attempts to reproduce the lost experience of forbidden pleasure with other men, ending in hopeless affairs. According to DSM-IV the patient had-besides social phobia-several personality disturbances, clinically manifested by weak ego boundaries, an unclear identity, and low self-esteem. Cognitive-behavioural therapy and psychopharmaca were without any effect. The childhood experiences were repeated in the context of the analysis and worked through, especially the pre-oedipal and oedipal conflicts. Important repeating themes were "crime", guilt, and punishment. After 3 years of analysis it was possible for the patient to expose herself to anxiety-producing situations with less symptoms. It was possible for her to withdraw the projections and take more responsibility for the unconscious sexual and aggressive impulses. At the 5-year follow-up her satisfactions had become more realistic and she became involved in a positive relationship.
Reproducibility of dynamically represented acoustic lung images from healthy individuals
Maher, T M; Gat, M; Allen, D; Devaraj, A; Wells, A U; Geddes, D M
2008-01-01
Background and aim: Acoustic lung imaging offers a unique method for visualising the lung. This study was designed to demonstrate reproducibility of acoustic lung images recorded from healthy individuals at different time points and to assess intra- and inter-rater agreement in the assessment of dynamically represented acoustic lung images. Methods: Recordings from 29 healthy volunteers were made on three separate occasions using vibration response imaging. Reproducibility was measured using quantitative, computerised assessment of vibration energy. Dynamically represented acoustic lung images were scored by six blinded raters. Results: Quantitative measurement of acoustic recordings was highly reproducible with an intraclass correlation score of 0.86 (very good agreement). Intraclass correlations for inter-rater agreement and reproducibility were 0.61 (good agreement) and 0.86 (very good agreement), respectively. There was no significant difference found between the six raters at any time point. Raters ranged from 88% to 95% in their ability to identically evaluate the different features of the same image presented to them blinded on two separate occasions. Conclusion: Acoustic lung imaging is reproducible in healthy individuals. Graphic representation of lung images can be interpreted with a high degree of accuracy by the same and by different reviewers. PMID:18024534
Mesoporous Nickel Oxide (NiO) Nanopetals for Ultrasensitive Glucose Sensing
NASA Astrophysics Data System (ADS)
Mishra, Suryakant; Yogi, Priyanka; Sagdeo, P. R.; Kumar, Rajesh
2018-01-01
Glucose sensing properties of mesoporous well-aligned, dense nickel oxide (NiO) nanostructures (NSs) in nanopetals (NPs) shape grown hydrothermally on the FTO-coated glass substrate has been demonstrated. The structural study based investigations of NiO-NPs has been carried out by X-ray diffraction (XRD), electron and atomic force microscopies, energy dispersive X-ray (EDX), and X-ray photospectroscopy (XPS). Brunauer-Emmett-Teller (BET) measurements, employed for surface analysis, suggest NiO's suitability for surface activity based glucose sensing applications. The glucose sensor, which immobilized glucose on NiO-NPs@FTO electrode, shows detection of wide range of glucose concentrations with good linearity and high sensitivity of 3.9 μA/μM/cm2 at 0.5 V operating potential. Detection limit of as low as 1 μΜ and a fast response time of less than 1 s was observed. The glucose sensor electrode possesses good anti-interference ability, stability, repeatability & reproducibility and shows inert behavior toward ascorbic acid (AA), uric acid (UA) and dopamine acid (DA) making it a perfect non-enzymatic glucose sensor.
π-Extended triptycene-based material for capillary gas chromatographic separations.
Yang, Yinhui; Wang, Qinsi; Qi, Meiling; Huang, Xuebin
2017-10-02
Triptycene-based materials feature favorable physicochemical properties and unique molecular recognition ability that offer good potential as stationary phases for capillary gas chromatography (GC). Herein, we report the investigation of utilizing a π-extended triptycene material (denoted as TQPP) for GC separations. As a result, the TQPP capillary column exhibited high column efficiency of 4030 plates m -1 and high-resolution performance for a wide range of analytes, especially structural and positional isomers. Interestingly, the TQPP stationary phase showed unique shape selectivity for alkanes isomers and preferential retention for analytes with halogen atoms and H-bonding nature mainly through their halogen-bonding and H-bonding interactions. In addition, the TQPP column had good repeatability and reproducibility with the RSD values of 0.02-0.34% for run-to-run, 0.09-0.80% for day-to-day and 1.4-5.2% for column-to-column, respectively, and favorable thermal stability up to 280 °C. This work demonstrates the promising future of triptycene-based materials as a new class of stationary phases for GC separations. Copyright © 2017 Elsevier B.V. All rights reserved.
Maceira, Alicia M; Tuset-Sanchis, Luis; López-Garrido, Miguel; San Andres, Marta; López-Lereu, M Pilar; Monmeneu, Jose V; García-González, M Pilar; Higueras, Laura
2018-05-01
The measurement of myocardial deformation by strain analysis is an evolving tool to quantify regional and global myocardial function. To assess the feasibility and reproducibility of myocardial strain/strain rate measurements with magnetic resonance feature tracking (MR-FT) in healthy subjects and in patient groups. Prospective study. Sixty patients (20 hypertensives with left ventricular (LV) hypertrophy (H); 20 nonischemic dilated cardiomyopathy (D); 20 ischemic heart disease (I); as well as 20 controls (C) were included, 10 men and 10 women in each group. A 1.5T MR protocol including steady-state free precession (SSFP) cine sequences in the standard views and late enhancement sequences. LV volumes, mass, global and regional radial, circumferential, and longitudinal strain/strain rate were measured using CVI42 software. The analysis time was recorded. Intraobserver and interobserver agreement and intraclass correlation coefficients (ICC) were obtained for reproducibility assessment as well as differences according to gender and group of pertinence. Strain/strain rate analysis could be achieved in all subjects. The average analysis time was 14 ± 3 minutes. The average intraobserver ICC was excellent (ICC >0.90) for strain and good (ICC >0.75) for strain rate. Reproducibility of strain measurements was good to excellent (ICC >0.75) for all groups of subjects and both genders. Reproducibility of strain measurements was good for basal segments (ICC >0.75) and excellent for middle and apical segments (ICC >0.90). Reproducibility of strain rate measurements was moderate for basal segments (ICC >0.50) and good for middle and apical segments. MR-FT for strain/strain rate analysis is a feasible and highly reproducible technique. CVI42 FT analysis was equally feasible and reproducible in various pathologies and between genders. Better reproducibility was seen globally for middle and apical segments, which needs further clarification. 3 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2018;47:1415-1425. © 2017 International Society for Magnetic Resonance in Medicine.
Dehghan, M; Ilow, R; Zatonska, K; Szuba, A; Zhang, X; Mente, A; Regulska-Ilow, B
2012-06-01
A food frequency questionnaire (FFQ) is the most commonly used method in large epidemiological studies. The validation of an FFQ is essential for specific populations because foods are culture-dependent. The present study aimed to develop an FFQ and evaluate its validity and reproducibility in estimating the intake of nutrients in urban and rural areas of Poland. Adult participants (n = 146) in the Polish arm of the ongoing Prospective Urban and Rural Epidemiological (PURE) study completed FFQs on two occasions, as well as four 24-h dietary recalls (DRs) during a 12-month period. Correlation coefficients (r) and de-attenuated correlation coefficients between dietary recalls and both FFQs were calculated for selected macro- and micronutrients. Agreement between the two methods was evaluated by classification into quartiles and the Bland-Altman method. Reproducibility was assessed by the intra-class correlation coefficient (ICC). The final food list contained 134 food items. For urban participants, FFQ2 generally underestimated energy, protein and fat compared to the FFQ1 and mean of DRs. In rural areas, compared to DRs, both FFQs overestimated energy and macronutrients. For both urban and rural settings, de-attenuated correlation exceeded 0.4 for almost all nutrients and the exact agreement in quartile categorisation was >66%. When assessing repeatability, ICC varied from 0.39-0.63 in an urban setting and 0.19-0.45 in a rural setting. This 134-item FFQ has good validity and reproducibility in relation to the reference method and can be used to rank individuals based on their macro- and micronutrient intake. © 2012 The Authors. Journal of Human Nutrition and Dietetics © 2012 The British Dietetic Association Ltd.
Palkovits, Stefan; Hirnschall, Nino; Georgiev, Stefan; Leisser, Christoph
2018-01-01
Purpose To evaluate the test–retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. Methods Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test–retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. Results Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] −1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR −1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. Conclusion The microperimeter MP3 shows an adequate test–retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. Translational Relevance Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies. PMID:29430338
Palkovits, Stefan; Hirnschall, Nino; Georgiev, Stefan; Leisser, Christoph; Findl, Oliver
2018-02-01
To evaluate the test-retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test-retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] -1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR -1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. The microperimeter MP3 shows an adequate test-retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies.
Validation of a thermal threshold nociceptive model in bearded dragons (Pogona vitticeps).
Couture, Émilie L; Monteiro, Beatriz P; Aymen, Jessica; Troncy, Eric; Steagall, Paulo V
2017-05-01
To validate a thermal threshold (TT) nociceptive model in bearded dragons (Pogona vitticeps) and to document TT changes after administration of morphine. A two-part randomized, blinded, controlled, experimental study. Five adult bearded dragons (242-396 g). A TT device delivered a ramped nociceptive stimulus (0.6 °C second -1 ) to the medial thigh until a response (leg kick/escape behavior) was observed or maximum (cut-off) temperature of 62 °C was reached. In phase I, period 1, six TT readings were determined at 20 minute intervals for evaluation of repeatability. Two of these readings were randomly assigned to be sham to assess specificity of the behavioral response. The same experiment was repeated 2 weeks later (period 2) to test reproducibility. In phase II, animals were administered either intramuscular morphine (10 mg kg -1 ) or saline 0.9%. TTs (maximum 68 °C) were determined before and 2, 4, 8, 12 and 24 hours after treatment administration. Data were analyzed using one-way anova (temporal changes and repeatability) and paired t tests (reproducibility and treatment comparisons) using Bonferroni correction (p < 0.05). Mean TT values were 57.4 ± 3.8 °C and 57.3 ± 4.3 °C for periods 1 and 2, respectively. Data were repeatable within each period (p = 0.83 and p = 0.07, respectively). Reproducibility between periods was remarkable (p = 0.86). False-positive responses during sham testing were 10%. TTs were significantly increased after morphine administration at 2, 4 and 8 hours compared with baseline, and at 2 and 4 hours compared with saline 0.9%. The highest TT was 67.7 ± 0.7 °C at 4 hours after morphine administration. Testing was repeatable, reproducible and well tolerated in bearded dragons. TT nociceptive testing detected morphine administration and may be suitable for studying opioid regimens in bearded dragons. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.
Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.; Agrawal, Nitin; Tang, Keqi; Smith, Richard D.
2011-01-01
A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed. PMID:21520147
Experimental investigations into visual and electronic tooth color measurement.
Ratzmann, Anja; Treichel, Anja; Langforth, Gabriele; Gedrange, Tomasz; Welk, Alexander
2011-04-01
The present study aimed to examine the validity of the visual color assessment and an electronic tooth color measurement system by means of Shade Inspector™ in comparison with a gold standard. Additionally, reproducibility of electronic measurements was demonstrated by means of two reference systems. Ceramic specimens of two thicknesses (h=1.6 mm, h=2.6 mm) were used. Three experienced dental technicians using the VITAPAN Classical(®) color scale carried out all visual tests. Validity of the visual assessment and the electronic measurements was confirmed separately for both thicknesses by means of lightness and hue of the VITAPAN Classical(®) color scale. Reproducibility of electronic measurements was confirmed by means of the VITAPAN Classical(®) and 3D-Master(®). The 3D-Master(®) data were calculated according to lightness, hue and chroma. Intraclass correlation coefficient (ICC) was used in assessing validity/reproducibility for lightness and chroma, Kappa statistics were used for hue. A level ≥0.75 was pre-established for ICC and ≥0.60 for the Kappa index. RESULTS OF VISUAL COLOR ASSESSMENT: Validity for lightness was good for both thicknesses; agreement rates for hue were inconsistent. ELECTRONIC MEASUREMENT: Validity for lightness was fair to good, hue values were below 0.60. Reproducibility of lightness was good to very good for both reference systems. Hue values (VITAPAN Classical(®)) for 1.6 mm test specimens were upside, for 2.6 mm below 0.60, Kappa values for 3D-Master(®) were ≥0.60 for all measurements, reproducibility of chroma was very good. Validity was better for visual than for electronic color assessment. Reproducibility of the electronic device by means of the Shade Inspector™ was given for the VITAPAN Classical(®) and 3D-Master(®) systems.
NASA Astrophysics Data System (ADS)
Ravikumar, Nakul; Rogalski, Melissa M.; Benza, Donny; Lake, Joshua; Urban, Matthew; Pelham, Hunter; Anker, Jeffrey N.; DesJardins, John D.
2017-03-01
An orthopaedic screw was designed with an optical tension-indicator to non-invasively quantify screw tension and monitor the load sharing between the bone and the implant. The screw both applies load to the bone, and measures this load by reporting the strain on the screw. The screw contains a colorimetric optical encoder that converts axial strain into colorimetric changes visible through the head of the screw, or luminescent spectral changes that are detected through tissue. Screws were tested under cyclic mechanical loading to mimic in-vivo conditions to verify the sensitivity, repeatability, and reproducibility of the sensor. In the absence to tissue, color was measured using a digital camera as a function of axial load on a stainless steel cannulated (hollow) orthopedic screw, modified by adding a passive colorimetric strain gauge through the central hole. The sensor was able to quantify clinically-relevant bone healing strains. The sensor exhibited good repeatability and reproducibility but also displayed hysteresis due to the internal mechanics of the screw. The strain indicator was also modified for measurement through tissue by replacing the reflective colorimetric sensor with a low-background X-ray excited optical luminescence signal. Luminescent spectra were acquired through 6 mm of chicken breast tissue. Overall, this research shows feasibility for a unique device which quantifies the strain on an orthopedic screw. Future research will involve reducing hysteresis by changing the mechanism of strain transduction in the screw, miniaturizing the luminescent strain gauge, monitoring bending as well as tension, using alternative luminescent spectral rulers based upon near infrared fluorescence or upconversion luminescence, and application to monitoring changes in pretension and load sharing during bone healing.
Gascoyne-Binzi, Deborah M.; Barlow, Rachael E. L.; Frothingham, Richard; Robinson, Grant; Collyns, Timothy A.; Gelletlie, Ruth; Hawkey, Peter M.
2001-01-01
Compared with solid media, broth-based mycobacterial culture systems have increased sensitivity but also have higher false-positive rates due to cross-contamination. Systematic strain typing is rarely undertaken because the techniques are technically demanding and the data are difficult to organize. Variable number tandem repeat (VNTR) analysis by PCR is rapid and reproducible. The digital profile is easily manipulated in a database. We undertook a retrospective study of Mycobacterium tuberculosis isolates collected over an 18-month period following the introduction of the BACTEC MGIT 960 system. VNTR allele profiles were determined with early positive broth cultures and entered into a database with the specimen processing date and other specimen data. We found 36 distinct VNTR profiles in cultures from 144 patients. Three common VNTR profiles accounted for 45% of true-positive cases. By combining VNTR results with specimen data, we identified nine cross-contamination incidents, six of which were previously unsuspected. These nine incidents resulted in 34 false-positive cultures for 29 patients. False-positive cultures were identified for three patients who had previously been culture positive for tuberculosis and were receiving treatment. Identification of cross-contamination incidents requires careful documentation of specimen data and good communication between clinical and laboratory staff. Automated broth culture systems should be supplemented with molecular analysis to identify cross-contamination events. VNTR analysis is reproducible and provides timely results when applied to early positive broth cultures. This method should ensure that patients are not placed on unnecessary tuberculosis therapy or that cases are not falsely identified as treatment failures. In addition, areas where existing procedures may be improved can be identified. PMID:11136751
van Mil, Anke C C M; Greyling, Arno; Zock, Peter L; Geleijnse, Johanna M; Hopman, Maria T; Mensink, Ronald P; Reesink, Koen D; Green, Daniel J; Ghiadoni, Lorenzo; Thijssen, Dick H
2016-09-01
Brachial artery flow-mediated dilation (FMD) is a popular technique to examine endothelial function in humans. Identifying volunteer and methodological factors related to variation in FMD is important to improve measurement accuracy and applicability. Volunteer-related and methodology-related parameters were collected in 672 volunteers from eight affiliated centres worldwide who underwent repeated measures of FMD. All centres adopted contemporary expert-consensus guidelines for FMD assessment. After calculating the coefficient of variation (%) of the FMD for each individual, we constructed quartiles (n = 168 per quartile). Based on two regression models (volunteer-related factors and methodology-related factors), statistically significant components of these two models were added to a final regression model (calculated as β-coefficient and R). This allowed us to identify factors that independently contributed to the variation in FMD%. Median coefficient of variation was 17.5%, with healthy volunteers demonstrating a coefficient of variation 9.3%. Regression models revealed age (β = 0.248, P < 0.001), hypertension (β = 0.104, P < 0.001), dyslipidemia (β = 0.331, P < 0.001), time between measurements (β = 0.318, P < 0.001), lab experience (β = -0.133, P < 0.001) and baseline FMD% (β = 0.082, P < 0.05) as contributors to the coefficient of variation. After including all significant factors in the final model, we found that time between measurements, hypertension, baseline FMD% and lab experience with FMD independently predicted brachial artery variability (total R = 0.202). Although FMD% showed good reproducibility, larger variation was observed in conditions with longer time between measurements, hypertension, less experience and lower baseline FMD%. Accounting for these factors may improve FMD% variability.
Pedersen, Ken Steen; Stege, Helle; Nielsen, Jens Peter
2011-07-01
Microwave drying as a procedure for determination of faecal dry matter in weaned pigs was evaluated and clinical relevant cut-off values between faecal consistency scores were determined. Repeatability and reproducibility were evaluated. Overall coefficient of variation was 0.03. The 95% confidence limits for any future faecal subsample examined by any operator in any replica were ± 0.85% faecal dry matter. Robustness in relation to weight of wet faeces was evaluated. The weight categories were 0.5, 1.0, 1.5, 2.0 and 3.0 g. Samples of 0.5 g gave significantly different mean faecal dry matter content compared to weighing of 1.0-3.0 g. Agreement with freeze-drying was evaluated. Lin's concordance correlation coefficient was 0.94. On average the faecal dry matter values was 1.7% (SD=1.99%) higher in freeze dried compared to micro waved samples. Non-parametric ROC analyses were used to determine optimal faecal dry matter cut-off values for clinical faecal consistency scores. The 4 consistency scores were score 1=firm and shaped, score 2=soft and shaped, score 3=loose and score 4=watery. The cut-off values were score 1: faecal dry matter content >19.5%, score 2: faecal dry matter content ≤ 19.5% and >18.0%, score 3: faecal dry matter content ≤ 18.0% and >11.3%, score 4: faecal dry matter content ≤ 11.3%. In conclusion, the microwave procedure has an acceptable repeatability/reproducibility and good agreement with freeze drying can be expected. A minimum of 1.0 g of wet faeces must be used for analyses. Faecal dry matter cut-off values between 4 different clinical consistency scores were determined. © 2011 Elsevier B.V. All rights reserved.
[Nuclear medicine diagnosis of pulmonary capillary protein leakage].
Creutzig, H; Sturm, J A; Schober, O; Nerlich, M L; Kant, C J
1984-10-01
Pulmonary extravascular albumin extravasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation of abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques.
Fung, David C Y; Wilkins, Marc R; Hart, David; Hong, Seok-Hee
2010-07-01
The force-directed layout is commonly used in computer-generated visualizations of protein-protein interaction networks. While it is good for providing a visual outline of the protein complexes and their interactions, it has two limitations when used as a visual analysis method. The first is poor reproducibility. Repeated running of the algorithm does not necessarily generate the same layout, therefore, demanding cognitive readaptation on the investigator's part. The second limitation is that it does not explicitly display complementary biological information, e.g. Gene Ontology, other than the protein names or gene symbols. Here, we present an alternative layout called the clustered circular layout. Using the human DNA replication protein-protein interaction network as a case study, we compared the two network layouts for their merits and limitations in supporting visual analysis.
Herold, Christian; Ueberreiter, Klaus; Busche, Marc N; Vogt, Peter M
2013-04-01
Autologous fat transplantation has gained great recognition in aesthetic and reconstructive surgery. Two main aspects are of predominant importance for progress control after autologous fat transplantation to the breast: quantitative information about the rate of fat survival in terms of effective volume persistence and qualitative information about the breast tissue to exclude potential complications of autologous fat transplantation. There are several tools available for use in evaluating the rate of volume survival. They are extensively compared in this review. The anthropometric method, thermoplastic casts, and Archimedes' principle of water displacement are not up to date anymore because of major drawbacks, first and foremost being reduced reproducibility and exactness. They have been replaced by more exact and reproducible tools such as MRI volumetry or 3D body surface scans. For qualitative and quantitative progress control, MRI volumetry offers all the necessary information: evaluation of fat survival and diagnostically valuable imaging to exclude possible complications of autologous fat transplantation. For frequent follow-up, e.g., monthly volume analysis, repeated MRI exams would not be good for the patient and are not cost effective. In these cases, 3D surface imaging is a good tool and especially helpful in a private practice setting where fast data acquisition is needed. This tool also offers the possibility of simulating the results of autologous fat transplantation. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Leurquin-Sterk, Gil; Postnov, Andrey; de Laat, Bart; Casteels, Cindy; Celen, Sofie; Crunelle, Cleo L; Bormans, Guy; Koole, Michel; Van Laere, Koen
2016-04-01
(18)F-FPEB is a promising PET tracer for studying the metabotropic glutamate subtype 5 receptor (mGluR5) expression in neuropsychiatric disorders. To assess the potential of (18)F-FPEB for longitudinal mGluR5 evaluation in patient studies, we evaluated the long-term test-retest reproducibility using various kinetic models in the human brain. Nine healthy volunteers underwent consecutive scans separated by a 6-month period. Dynamic PET was combined with arterial sampling and radiometabolite analysis. Total distribution volume (V(T)) and nondisplaceable binding potential (BP(ND)) were derived from a two-tissue compartment model without constraints (2TCM) and with constraining the K(1)/k(2) ratio to the value of either cerebellum (2TCM-CBL) or pons (2TCM-PONS). The effect of fitting different functions to the tracer parent fractions and reducing scan duration were assessed. Regional absolute test-retest variability (aTRV), coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were computed. The 2TCM-CBL showed best fits. The mean 6-month aTRV of V(T) ranged from 8 to 13% (CR < 25%) with ICC > 0.6 for all kinetic models. BPND from 2TCM-CBL with a sigmoid fit for the parent fractions showed the best reproducibility, with aTRV ≤ 7% (CR < 16%) and ICC > 0.9 in most regions. Reducing the scan duration from 90 to 60 min did not affect reproducibility. These results demonstrate for the first time that (18)F-FPEB brain PET has good long-term reproducibility, therefore validating its use to monitor mGluR5 expression in longitudinal clinical studies. We suggest a 2TCM-CBL with fitting a sigmoid function to the parent fractions to be optimal for this tracer. © 2016 Wiley Periodicals, Inc.
Scott, Andrew D; Keegan, Jennifer; Firmin, David N
2011-01-01
To quantitatively assess the performance and reproducibility of 3D spiral coronary artery wall imaging with beat-to-beat respiratory-motion-correction (B2B-RMC) compared to navigator gated 2D spiral and turbo-spin-echo (TSE) acquisitions. High-resolution (0.7 × 0.7 mm) cross-sectional right coronary wall acquisitions were performed in 10 subjects using four techniques (B2B-RMC 3D spiral with alternate (2RR) and single (1RR) R-wave gating, navigator-gated 2D spiral (2RR) and navigator-gated 2D TSE (2RR)) on two occasions. Wall thickness measurements were compared with repeated measures analysis of variance (ANOVA). Reproducibility was assessed with the intraclass correlation coefficient (ICC). In all, 91% (73/80) of acquisitions were successful (failures: four TSE, two 3D spiral (1RR) and one 3D spiral (2RR)). Respiratory efficiency of the B2B-RMC was less variable and substantially higher than for navigator gating (99.6 ± 1.2% vs. 39.0 ± 7.5%, P < 0.0001). Coronary wall thicknesses (± standard deviation [SD]) were not significantly different: 1.10 ± 0.14 mm (3D spiral (2RR)), 1.20 ± 0.16 mm (3D spiral (1RR)), 1.14 ± 0.15 mm (2D spiral), and 1.21 ± 0.17 mm (TSE). Wall thickness reproducibility ranged from good (ICC = 0.65, 3D spiral (1RR)) to excellent (ICC = 0.87, 3D spiral (2RR)). High-resolution 3D spiral imaging with B2B-RMC permits coronary vessel wall assessment over multiple thin contiguous slices in a clinically feasible duration. Excellent reproducibility of the technique potentially enables studies of disease progression/regression. Copyright © 2010 Wiley-Liss, Inc.
Chiu, Tina H T; Huang, Hui-Ya; Chen, Kuan-Ju; Wu, Yu-R U; Chiu, Jason P C; Li, Yi-Hwei; Chiu, Brian C-H; Lin, Chin-Lon; Lin, Ming-Nan
2014-07-01
To assess the relative validity and reproducibility of the quantitative FFQ used in the Tzu Chi Health Study (TCHS). The reproducibility was evaluated by comparing the baseline FFQ with the 2-year follow-up FFQ. The validity was evaluated by comparing the baseline FFQ with 3 d dietary records and biomarkers (serum folate and vitamin B12). Median comparison, cross-classification and Spearman correlation with and without energy adjustment and deattenuation for day-to-day variation were assessed. TCHS is a prospective cohort containing a high proportion of true vegetarians and part-time vegetarians (regularly consuming a vegetarian diet without completely avoiding meat). Subsets of 103, seventy-eight and 1528 TCHS participants were included in the reproducibility, dietary record-validity and biomarker-validity studies, respectively. Correlations assessing the reproducibility for repeat administrations of the FFQ were in the range of 0·46-0·65 for macronutrients and 0·35-0·67 for micronutrients; the average same quartile agreement was 40%. The correlation between FFQ and biomarkers was 0·41 for both vitamin B12 and folate. Moderate to good correlations between the baseline FFQ and dietary records were found for energy, protein, carbohydrate, saturated and monounsaturated fat, fibre, vitamin C, vitamin A, K, Ca, Mg, P, Fe and Zn (average crude correlation: 0·47 (range: 0·37-0·66); average energy-adjusted correlation: 0·43 (range: 0·38-0·55); average energy-adjusted deattenuated correlation: 0·50 (range: 0·44-0·66)) with same quartile agreement rate of 39% (range: 35-45%), while misclassification to the extreme quartile was rare (average: 4% (range: 0-6%)). The FFQ is a reliable and valid tool to rank relative intake of major nutrients for TCHS participants.
Miyazaki, Keiko; Jerome, Neil P; Collins, David J; Orton, Matthew R; d'Arcy, James A; Wallace, Toni; Moreno, Lucas; Pearson, Andrew D J; Marshall, Lynley V; Carceller, Fernando; Leach, Martin O; Zacharoulis, Stergios; Koh, Dow-Mu
2015-09-01
The objectives are to examine the reproducibility of functional MR imaging in children with solid tumours using quantitative parameters derived from diffusion-weighted (DW-) and dynamic contrast enhanced (DCE-) MRI. Patients under 16-years-of age with confirmed diagnosis of solid tumours (n = 17) underwent free-breathing DW-MRI and DCE-MRI on a 1.5 T system, repeated 24 hours later. DW-MRI (6 b-values, 0-1000 sec/mm(2)) enabled monoexponential apparent diffusion coefficient estimation using all (ADC0-1000) and only ≥100 sec/mm(2) (ADC100-1000) b-values. DCE-MRI was used to derive the transfer constant (K(trans)), the efflux constant (kep), the extracellular extravascular volume (ve), and the plasma fraction (vp), using a study cohort arterial input function (AIF) and the extended Tofts model. Initial area under the gadolinium enhancement curve and pre-contrast T1 were also calculated. Percentage coefficients of variation (CV) of all parameters were calculated. The most reproducible cohort parameters were ADC100-1000 (CV = 3.26%), pre-contrast T1 (CV = 6.21%), and K(trans) (CV = 15.23%). The ADC100-1000 was more reproducible than ADC0-1000, especially extracranially (CV = 2.40% vs. 2.78%). The AIF (n = 9) derived from this paediatric population exhibited sharper and earlier first-pass and recirculation peaks compared with the literature's adult population average. Free-breathing functional imaging protocols including DW-MRI and DCE-MRI are well-tolerated in children aged 6 - 15 with good to moderate measurement reproducibility. • Diffusion MRI protocol is feasible and well-tolerated in a paediatric oncology population. • DCE-MRI for pharmacokinetic evaluation is feasible and well tolerated in a paediatric oncology population. • Paediatric arterial input function (AIF) shows systematic differences from the adult population-average AIF. • Variation of quantitative parameters from paired functional MRI measurements were within 20%.
A gas chromatography-mass spectrometry assay to quantify camphor extracted from goat serum.
Lee, Kyung-Min; Dai, Susie Y; Herrman, Timothy J; Musser, Jeffrey M B
2012-09-15
A sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for quantification and pharmacokinetics of camphor, a major monoterpene of juniper plant, in goat serum. Camphor and internal standard (terpinolene) eluates from solid phase extraction (SPE) with ethyl acetate yielded well resolved peaks and were clearly identified in total and selected ion chromatograms. The elution and injection volumes were optimized for improved detection and quantification of camphor based on peak shape, signal to noise ratio, recoveries, and repeatability. The matrix calibration curve with the good linearity (R(2)=0.998) and response in the range of 0.005-10.0 μg/mL was used to determine camphor concentration in goat serum. The GC-MS method offered sufficiently low limits of detection (1 ng/mL) and quantitation (3 ng/mL) for camphor concentration in goat serum for the pharmacokinetic study. The proposed method showed good intra- and inter-day variation with relative standard deviation (RSD) of 0.2-7.7% and produced good recovery (96.0-111.6%) and reproducibility (1.6-6.1%) at all spiked levels. Using this method on serum samples obtained from two goats orally dosed with camphor confirmed that the method is suitable for camphor studies in animals. Copyright © 2012 Elsevier B.V. All rights reserved.
Panchani, Sunil; Reading, Jonathan; Mehta, Jaysheel
2016-06-01
The position of the lateral sesamoid on standard dorso-plantar weight bearing radiographs, with respect to the lateral cortex of the first metatarsal, has been shown to correlate well with the degree of the hallux valgus angle. This study aimed to assess the inter- and intra-observer error of this new classification system. Five orthopaedic consultants and five trainee orthopaedic surgeons were recruited to assess and document the degree of displacement of the lateral sesamoid on 144 weight-bearing dorso-plantar radiographs on two separate occasions. The severity of hallux valgus was defined as normal (0%), mild (≤50%), moderate (51-≤99%) or severe (≥100%) depending on the percentage displacement of the lateral sesamoid body from the lateral cortical border of the first metatarsal. Consultant intra-observer variability showed good agreement between repeated assessment of the radiographs (mean Kappa=0.75). Intra-observer variability for trainee orthopaedic surgeons also showed good agreement with a mean Kappa=0.73. Intraclass correlations for consultants and trainee surgeons was also high. The new classification system of assessing the severity of hallux valgus shows high inter- and intra-observer variability with good agreement and reproducibility between surgeons of consultant and trainee grades. Copyright © 2015 Elsevier Ltd. All rights reserved.
van Gorp, Karly; Segers, Eliane; Verhoeven, Ludo
2017-04-01
The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed by a transfer task with a different set of items. Two weeks after training, trained items were assessed again in a retention test. Participants either received phonics feedback, in which each word was spelled out and repeated; word feedback, in which each word was repeated; or no feedback. During the training, both good and poor readers improved in accuracy and speed. The increase in speed was stronger for poor readers than for good readers. The good readers demonstrated a stronger increase for pseudowords than for words. This increase in speed was most prominent in the first four sessions. Two weeks after training, the levels of accuracy and speed were retained. Furthermore, transfer effects on speed were found for pseudowords in both groups of readers. Good readers performed most accurately during the training when they received no feedback while poor readers performed most accurately during the training with the help of phonics feedback. However, feedback did not differentiate for reading speed or for effects after the training. The effects of repeated word reading were found to be stronger for poor readers than for good readers. Moreover, these effects were found to be stronger for pseudowords than for words. This indicates that repeated word reading can be seen as an important trigger for the improvement of decoding skills.
Automated T2 relaxometry of the hippocampus for temporal lobe epilepsy.
Winston, Gavin P; Vos, Sjoerd B; Burdett, Jane L; Cardoso, M Jorge; Ourselin, Sebastien; Duncan, John S
2017-09-01
Hippocampal sclerosis (HS), the most common cause of refractory temporal lobe epilepsy, is associated with hippocampal volume loss and increased T2 signal. These can be identified on quantitative imaging with hippocampal volumetry and T2 relaxometry. Although hippocampal segmentation for volumetry has been automated, T2 relaxometry currently involves subjective and time-consuming manual delineation of regions of interest. In this work, we develop and validate an automated technique for hippocampal T2 relaxometry. Fifty patients with unilateral or bilateral HS and 50 healthy controls underwent T 1 -weighted and dual-echo fast recovery fast spin echo scans. Hippocampi were automatically segmented using a multi-atlas-based segmentation algorithm (STEPS) and a template database. Voxelwise T2 maps were determined using a monoexponential fit. The hippocampal segmentations were registered to the T2 maps and eroded to reduce partial volume effect. Voxels with T2 >170 msec excluded to minimize cerebrospinal fluid (CSF) contamination. Manual determination of T2 values was performed twice in each subject. Twenty controls underwent repeat scans to assess interscan reproducibility. Hippocampal T2 values were reliably determined using the automated method. There was a significant ipsilateral increase in T2 values in HS (p < 0.001), and a smaller but significant contralateral increase. The combination of hippocampal volumes and T2 values separated the groups well. There was a strong correlation between automated and manual methods for hippocampal T2 measurement (0.917 left, 0.896 right, both p < 0.001). Interscan reproducibility was superior for automated compared to manual measurements. Automated hippocampal segmentation can be reliably extended to the determination of hippocampal T2 values, and a combination of hippocampal volumes and T2 values can separate subjects with HS from healthy controls. There is good agreement with manual measurements, and the technique is more reproducible on repeat scans than manual measurement. This protocol can be readily introduced into a clinical workflow for the assessment of patients with focal epilepsy. © 2017 The Authors. Epilepsia published by Wiley Periodicals, Inc. on behalf of International League Against Epilepsy.
McAlinden, Colm; Khadka, Jyoti; Pesudovs, Konrad
2011-07-01
The ever-expanding choice of ocular metrology and imaging equipment has driven research into the validity of their measurements. Consequently, studies of the agreement between two instruments or clinical tests have proliferated in the ophthalmic literature. It is important that researchers apply the appropriate statistical tests in agreement studies. Correlation coefficients are hazardous and should be avoided. The 'limits of agreement' method originally proposed by Altman and Bland in 1983 is the statistical procedure of choice. Its step-by-step use and practical considerations in relation to optometry and ophthalmology are detailed in addition to sample size considerations and statistical approaches to precision (repeatability or reproducibility) estimates. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.
Hamer, Mark; Boutcher, Yati N; Park, Young; Boutcher, Stephen H
2006-08-01
Skeletal muscle blood flow responses to stress have implications for psychobiological disease pathways. An important assumption underlying psychophysiological studies relating stress reactivity with disease risk is that individuals are characterized by stable response profiles that can be reliably assessed using acute psychophysiological stress testing. We examined the reproducibility of forearm vasodilatation, blood pressure, and cardiac responses to a 2 min Stroop mental challenge over two repeated stress sessions that were on average 3.6 months apart. Participants were 21 healthy men and women (aged 21.8+/-3.7 years). Vasodilatation, blood pressure and heart rate responses displayed no habituation between sessions, although there was significantly greater cardiac parasympathetic involvement during the second testing session. Significant test-retest correlations between the sessions were observed for both forearm blood flow and heart rate reactivity. These findings demonstrate skeletal muscle vasodilatation responses to repeated stress are robust, so may be a useful psychophysiological indicator in studies of stress reactivity and disease risk.
Effects of Simple Leaching of Crushed and Powdered Materials on High-precision Pb Isotope Analyses
NASA Astrophysics Data System (ADS)
Todd, E.; Stracke, A.
2013-12-01
We present new results of simple leaching experiments on the Pb isotope composition of USGS standard reference material powders and on ocean island basalt whole rock splits and powders. Rock samples were leached with 6N HCl in two steps, first hot and then in an ultrasonic bath, and washed with ultrapure H2O before conventional sample digestion and chromatographic purification of Pb. Pb isotope analyses were determined with Tl-doped MC-ICP-MS. Intra- and inter-session analytical reproducibility of repeated analyses of both synthetic Pb solutions and Pb from single digests of chemically processed natural samples were generally < 100 ppm (2 S.D.). The comparison of leached and unleached samples shows that leaching reliably removes variable amounts of different contaminants for different starting materials. For repeated digests of a single sample, the leached samples reproduce better than the unleached ones, showing that leaching effectively removes heterogeneously distributed extraneous Pb. However, the reproducibility of repeated digests of variably contaminated natural samples is up to an order of magnitude worse than the analytical reproducibility of ca. 100 ppm. More complex leaching methods (e.g., Nobre Silva et al., 2009) yield Pb isotope ratios within error of and with similar reproducibility to our method, showing that the simple leaching method is reliable. The remaining Pb isotope heterogeneity of natural samples, which typically exceeds 100 ppm, is thus attributed to inherent isotopic sample heterogeneity. Tl-doped MC-ICP-MS Pb ratio determination is therefore a sufficiently precise method for Pb isotope analyses in natural rocks. More precise Pb double- or triple-spike methods (e.g., Galer, 1999; Thirlwall, 2000), may exploit their full potential only in cases where natural isotopic sample heterogeneity is demonstrably negligible. References: Galer, S., 1999, Chem. Geol. 157, 255-274. Nobre Silva, et al. 2009, Geochemistry Geophysics Geosystems 10, Q08012. Thirlwall, M.F., 2000, Chem. Geol. 163, 299-322.
Puri, Basant K; Egan, Mary; Wallis, Fintan; Jakeman, Philip
2018-03-22
To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift imaging (CSI) sequence. The data were analyzed in the same way, using the same software, to obtain the values for each voxel of the ratio of Cho to creatine. The Wilcoxon related-samples signed-rank test, coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC) were used to assess the repeatability. The CV ranged from 2.75% to 33.99%, while the minimum RC was 5.68%. There was excellent reproducibility, as judged by significant ICC values, in 26 voxels. Just three voxels showed significant differences according to the Wilcoxon related-samples signed-rank test. It is therefore concluded that when CSI multivoxel proton neurospectroscopy is used to measure cerebral choline-containing compounds at 1.5 T, the reproducibility is highly acceptable.
Quantitative analysis of airway abnormalities in CT
NASA Astrophysics Data System (ADS)
Petersen, Jens; Lo, Pechin; Nielsen, Mads; Edula, Goutham; Ashraf, Haseem; Dirksen, Asger; de Bruijne, Marleen
2010-03-01
A coupled surface graph cut algorithm for airway wall segmentation from Computed Tomography (CT) images is presented. Using cost functions that highlight both inner and outer wall borders, the method combines the search for both borders into one graph cut. The proposed method is evaluated on 173 manually segmented images extracted from 15 different subjects and shown to give accurate results, with 37% less errors than the Full Width at Half Maximum (FWHM) algorithm and 62% less than a similar graph cut method without coupled surfaces. Common measures of airway wall thickness such as the Interior Area (IA) and Wall Area percentage (WA%) was measured by the proposed method on a total of 723 CT scans from a lung cancer screening study. These measures were significantly different for participants with Chronic Obstructive Pulmonary Disease (COPD) compared to asymptomatic participants. Furthermore, reproducibility was good as confirmed by repeat scans and the measures correlated well with the outcomes of pulmonary function tests, demonstrating the use of the algorithm as a COPD diagnostic tool. Additionally, a new measure of airway wall thickness is proposed, Normalized Wall Intensity Sum (NWIS). NWIS is shown to correlate better with lung function test values and to be more reproducible than previous measures IA, WA% and airway wall thickness at a lumen perimeter of 10 mm (PI10).
Bi, Liyan; Wang, Yunqing; Yang, Ying; Li, Yuling; Mo, Shanshan; Zheng, Qingyin; Chen, Lingxin
2018-05-09
Conventional research on surface-enhanced Raman scattering (SERS)-based pH sensors often depends on nanoparticle aggregation, whereas the variability in nanoparticle aggregation gives rise to poor repeatability in the SERS signal. Herein, we fabricated a gold nanorod array platform via an efficient evaporative self-assembly method. The platform exhibits great SERS sensitivity with an enhancement factor of 5.6 × 10 7 and maintains excellent recyclability and reproducibility with relative standard deviation (RSD) values of less than 8%. On the basis of the platform, we developed a highly sensitive bovine serum albumin (BSA)-coated 4-mercaptopyridine (4-MPy)-linked (BMP) SERS-based pH sensor to report pH ranging from pH 3.0 to pH 8.0. The intensity ratio variation of 1004 and 1096 cm -1 in 4-MPy showed excellent pH sensitivity, which decreased as the surrounding pH increased. Furthermore, this BMP SERS-based pH sensor was employed to measure the pH value in C57BL/6 mouse blood. We have demonstrated that the pH sensor has great advantages such as good stability, reliability, and accuracy, which could be extended for the design of point-of-care devices.
Lassnig, R.; Striedinger, B.; Hollerer, M.; Fian, A.; Stadlober, B.; Winkler, A.
2015-01-01
The fabrication of organic thin film transistors with highly reproducible characteristics presents a very challenging task. We have prepared and analyzed model pentacene thin film transistors under ultra-high vacuum conditions, employing surface analytical tools and methods. Intentionally contaminating the gold contacts and SiO2 channel area with carbon through repeated adsorption, dissociation, and desorption of pentacene proved to be very advantageous in the creation of devices with stable and reproducible parameters. We mainly focused on the device properties, such as mobility and threshold voltage, as a function of film morphology and preparation temperature. At 300 K, pentacene displays Stranski-Krastanov growth, whereas at 200 K fine-grained, layer-like film growth takes place, which predominantly influences the threshold voltage. Temperature dependent mobility measurements demonstrate good agreement with the established multiple trapping and release model, which in turn indicates a predominant concentration of shallow traps in the crystal grains and at the oxide-semiconductor interface. Mobility and threshold voltage measurements as a function of coverage reveal that up to four full monolayers contribute to the overall charge transport. A significant influence on the effective mobility also stems from the access resistance at the gold contact-semiconductor interface, which is again strongly influenced by the temperature dependent, characteristic film growth mode. PMID:25814770
NASA Astrophysics Data System (ADS)
Lassnig, R.; Striedinger, B.; Hollerer, M.; Fian, A.; Stadlober, B.; Winkler, A.
2014-09-01
The fabrication of organic thin film transistors with highly reproducible characteristics presents a very challenging task. We have prepared and analyzed model pentacene thin film transistors under ultra-high vacuum conditions, employing surface analytical tools and methods. Intentionally contaminating the gold contacts and SiO2 channel area with carbon through repeated adsorption, dissociation, and desorption of pentacene proved to be very advantageous in the creation of devices with stable and reproducible parameters. We mainly focused on the device properties, such as mobility and threshold voltage, as a function of film morphology and preparation temperature. At 300 K, pentacene displays Stranski-Krastanov growth, whereas at 200 K fine-grained, layer-like film growth takes place, which predominantly influences the threshold voltage. Temperature dependent mobility measurements demonstrate good agreement with the established multiple trapping and release model, which in turn indicates a predominant concentration of shallow traps in the crystal grains and at the oxide-semiconductor interface. Mobility and threshold voltage measurements as a function of coverage reveal that up to four full monolayers contribute to the overall charge transport. A significant influence on the effective mobility also stems from the access resistance at the gold contact-semiconductor interface, which is again strongly influenced by the temperature dependent, characteristic film growth mode.
Repeatability and reproducibility of corneal thickness using SOCT Copernicus HR.
Vidal, Silvia; Viqueira, Valentín; Mas, David; Domenech, Begoña
2013-05-01
The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (S(W)) and the within-subject coefficient of variation (C(W)). The level of agreement by Bland-Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Penna, Rachele R; de Sanctis, Ugo; Catalano, Martina; Brusasco, Luca; Grignolo, Federico M
2017-01-01
To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf, 0.15 vs 0.56 for Ks, 0.09 vs 0.59 for Km, and 0.18 vs 0.23 for Ks-Kf. The 95% LoA were -0.54 to +0.58 for Kf, -0.51 to +0.53 for Ks and Km, and -0.28 to +0.27 for Ks-Kf. As compared with Placido disk-based topography, the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks, Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes.
Penna, Rachele R.; de Sanctis, Ugo; Catalano, Martina; Brusasco, Luca; Grignolo, Federico M.
2017-01-01
AIM To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). METHODS One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). RESULTS In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf, 0.15 vs 0.56 for Ks, 0.09 vs 0.59 for Km, and 0.18 vs 0.23 for Ks-Kf. The 95% LoA were -0.54 to +0.58 for Kf, -0.51 to +0.53 for Ks and Km, and -0.28 to +0.27 for Ks-Kf. CONCLUSION As compared with Placido disk-based topography, the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks, Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes. PMID:28393039
NASA Astrophysics Data System (ADS)
Clairon, A.; Dahmani, B.; Acef, O.; Granveaud, M.; Domnin, Yu S.; Pouchkine, S. B.; Tatarenkov, V. M.; Felder, R.
1988-01-01
Comparison of the VNIIFTRI and LPTF frequency multiplication chains has been carried out through the measurement of the frequency of a portable VNIIFTRI (He-Ne)/CH4 laser. Agreement is within 100 Hz (1.1 parts in 1012) and is secured by the very good medium-term frequency repeatability of the (He-Ne)/CH4 VNIIFTRI portable laser (a few parts in 1013). On the same occasion a measurement of the frequency of the BIPM (He-Ne)/CH4 reference laser (B.3) has been performed at LPTF. Other experiments carried out on the BIPM laser show that the reproducibility of the (He-Ne)/CH4 system could be improved by a systematic study and then by a better control of the various perturbing factors which influence the shape of the methane-saturated absorption peak.
Glaucoma diagnosis by mapping macula with Fourier domain optical coherence tomography
NASA Astrophysics Data System (ADS)
Tan, Ou; Lu, Ake; Chopra, Vik; Varma, Rohit; Hiroshi, Ishikawa; Schuman, Joel; Huang, David
2008-03-01
A new image segmentation method was developed to detect macular retinal sub-layers boundary on newly-developed Fourier-Domain Optical Coherence Tomography (FD-OCT) with macular grid scan pattern. The segmentation results were used to create thickness map of macular ganglion cell complex (GCC), which contains the ganglion cell dendrites, cell bodies and axons. Overall average and several pattern analysis parameters were defined on the GCC thickness map and compared for the diagnosis of glaucoma. Intraclass correlation (ICC) is used to compare the reproducibility of the parameters. Area under receiving operative characteristic curve (AROC) was calculated to compare the diagnostic power. The result is also compared to the output of clinical time-domain OCT (TD-OCT). We found that GCC based parameters had good repeatability and comparable diagnostic power with circumpapillary nerve fiber layer (cpNFL) thickness. Parameters based on pattern analysis can increase the diagnostic power of GCC macular mapping.
Application of solid/liquid extraction for the gravimetric determination of lipids in royal jelly.
Antinelli, Jean-François; Davico, Renée; Rognone, Catherine; Faucon, Jean-Paul; Lizzani-Cuvelier, Louisette
2002-04-10
Gravimetric lipid determination is a major parameter for the characterization and the authentication of royal jelly quality. A solid/liquid extraction was compared to the reference method, which is based on liquid/liquid extraction. The amount of royal jelly and the time of the extraction were optimized in comparison to the reference method. Boiling/rinsing ratio and spread of royal jelly onto the extraction thimble were identified as critical parameters, resulting in good accuracy and precision for the alternative method. Comparison of reproducibility and repeatability of both methods associated with gas chromatographic analysis of the composition of the extracted lipids showed no differences between the two methods. As the intra-laboratory validation tests were comparable to the reference method, while offering rapidity and a decrease in amount of solvent used, it was concluded that the proposed method should be used with no modification of quality criteria and norms established for royal jelly characterization.
NASA Astrophysics Data System (ADS)
Hao, Huadong; Shi, Haolei; Yi, Pengju; Liu, Ying; Li, Cunjun; Li, Shuguang
2018-01-01
A Volume Metrology method based on Internal Electro-optical Distance-ranging method is established for large vertical energy storage tank. After analyzing the vertical tank volume calculation mathematical model, the key processing algorithms, such as gross error elimination, filtering, streamline, and radius calculation are studied for the point cloud data. The corresponding volume values are automatically calculated in the different liquids by calculating the cross-sectional area along the horizontal direction and integrating from vertical direction. To design the comparison system, a vertical tank which the nominal capacity is 20,000 m3 is selected as the research object, and there are shown that the method has good repeatability and reproducibility. Through using the conventional capacity measurement method as reference, the relative deviation of calculated volume is less than 0.1%, meeting the measurement requirements. And the feasibility and effectiveness are demonstrated.
Memristive behavior of the SnO2/TiO2 interface deposited by sol-gel
NASA Astrophysics Data System (ADS)
Boratto, Miguel H.; Ramos, Roberto A.; Congiu, Mirko; Graeff, Carlos F. O.; Scalvi, Luis V. A.
2017-07-01
A novel and cheap Resistive Random Access Memory (RRAM) device is proposed within this work, based on the interface between antimony doped Tin Oxide (4%at Sb:SnO2) and Titanium Oxide (TiO2) thin films, entirely prepared through a low-temperature sol-gel process. The device was fabricated on glass slides using evaporated aluminum electrodes. Typical bipolar memristive behavior under cyclic voltage sweeping and square wave voltages, with well-defined high and low resistance states (HRS and LRS), and set and reset voltages are shown in our samples. The switching mechanism, explained by charges trapping/de-trapping by defects in the SnO2/TiO2 interface, is mainly driven by the external electric field. The calculated on/off ratio was about 8 × 102 in best conditions with good reproducibility over repeated measurement cycles under cyclic voltammetry and about 102 under applied square wave voltage.
Pourcel, Christine; Minandri, Fabrizia; Hauck, Yolande; D'Arezzo, Silvia; Imperi, Francesco; Vergnaud, Gilles; Visca, Paolo
2011-01-01
Acinetobacter baumannii is an important opportunistic pathogen responsible for nosocomial outbreaks, mostly occurring in intensive care units. Due to the multiplicity of infection sources, reliable molecular fingerprinting techniques are needed to establish epidemiological correlations among A. baumannii isolates. Multiple-locus variable-number tandem-repeat analysis (MLVA) has proven to be a fast, reliable, and cost-effective typing method for several bacterial species. In this study, an MLVA assay compatible with simple PCR- and agarose gel-based electrophoresis steps as well as with high-throughput automated methods was developed for A. baumannii typing. Preliminarily, 10 potential polymorphic variable-number tandem repeats (VNTRs) were identified upon bioinformatic screening of six annotated genome sequences of A. baumannii. A collection of 7 reference strains plus 18 well-characterized isolates, including unique types and representatives of the three international A. baumannii lineages, was then evaluated in a two-center study aimed at validating the MLVA assay and comparing it with other genotyping assays, namely, macrorestriction analysis with pulsed-field gel electrophoresis (PFGE) and PCR-based sequence group (SG) profiling. The results showed that MLVA can discriminate between isolates with identical PFGE types and SG profiles. A panel of eight VNTR markers was selected, all showing the ability to be amplified and good amounts of polymorphism in the majority of strains. Independently generated MLVA profiles, composed of an ordered string of allele numbers corresponding to the number of repeats at each VNTR locus, were concordant between centers. Typeability, reproducibility, stability, discriminatory power, and epidemiological concordance were excellent. A database containing information and MLVA profiles for several A. baumannii strains is available from http://mlva.u-psud.fr/. PMID:21147956
Comparison of three methods to assess individual skeletal maturity.
Pasciuti, Enzo; Franchi, Lorenzo; Baccetti, Tiziano; Milani, Silvano; Farronato, Giampietro
2013-09-01
The knowledge of facial growth and development is fundamental to determine the optimal timing for different treatment procedures in the growing patient. To analyze the reproducibility of three methods in assessing individual skeletal maturity, and to evaluate any degree of concordance among them. In all, 100 growing subjects were enrolled to test three methods: the hand-wrist, cervical vertebral maturation (CVM), and medial phalanges of the third finger method (MP3). Four operators determined the skeletal maturity of the subjects to evaluate the reproducibility of each method. After 30 days the operators repeated the analysis to assess the repeatability of each method. Finally, one operator examined all subjects' radiographs to detect any concordance among the three methods. The weighted kappa values for inter-operator variability were 0.94, 0.91, and 0.90, for the WRI, CVM, and MP3 methods, respectively. The weighted kappa values for intra-operator variability were 0.92, 0.91, and 0.92, for the WRI, CVM, and MP3 methods, respectively. The three methods revealed a high degree of repeatability and reproducibility. Complete agreement among the three methods was observed in 70% of the analyzed samples. The CVM method has the advantage of not necessitating an additional radiograph. The MP3 method is a simple and practical alternative as it requires only a standard dental x-ray device.
Liu, Hon-Man; Chen, Shan-Kai; Chen, Ya-Fang; Lee, Chung-Wei; Yeh, Lee-Ren
2016-01-01
Purpose To assess the inter session reproducibility of automatic segmented MRI-derived measures by FreeSurfer in a group of subjects with normal-appearing MR images. Materials and Methods After retrospectively reviewing a brain MRI database from our institute consisting of 14,758 adults, those subjects who had repeat scans and had no history of neurodegenerative disorders were selected for morphometry analysis using FreeSurfer. A total of 34 subjects were grouped by MRI scanner model. After automatic segmentation using FreeSurfer, label-wise comparison (involving area, thickness, and volume) was performed on all segmented results. An intraclass correlation coefficient was used to estimate the agreement between sessions. Wilcoxon signed rank test was used to assess the population mean rank differences across sessions. Mean-difference analysis was used to evaluate the difference intervals across scanners. Absolute percent difference was used to estimate the reproducibility errors across the MRI models. Kruskal-Wallis test was used to determine the across-scanner effect. Results The agreement in segmentation results for area, volume, and thickness measurements of all segmented anatomical labels was generally higher in Signa Excite and Verio models when compared with Sonata and TrioTim models. There were significant rank differences found across sessions in some labels of different measures. Smaller difference intervals in global volume measurements were noted on images acquired by Signa Excite and Verio models. For some brain regions, significant MRI model effects were observed on certain segmentation results. Conclusions Short-term scan-rescan reliability of automatic brain MRI morphometry is feasible in the clinical setting. However, since repeatability of software performance is contingent on the reproducibility of the scanner performance, the scanner performance must be calibrated before conducting such studies or before using such software for retrospective reviewing. PMID:26812647
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.
2011-04-26
A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersectionmore » geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.« less
A custom-built PET phantom design for quantitative imaging of printed distributions.
Markiewicz, P J; Angelis, G I; Kotasidis, F; Green, M; Lionheart, W R; Reader, A J; Matthews, J C
2011-11-07
This note presents a practical approach to a custom-made design of PET phantoms enabling the use of digital radioactive distributions with high quantitative accuracy and spatial resolution. The phantom design allows planar sources of any radioactivity distribution to be imaged in transaxial and axial (sagittal or coronal) planes. Although the design presented here is specially adapted to the high-resolution research tomograph (HRRT), the presented methods can be adapted to almost any PET scanner. Although the presented phantom design has many advantages, a number of practical issues had to be overcome such as positioning of the printed source, calibration, uniformity and reproducibility of printing. A well counter (WC) was used in the calibration procedure to find the nonlinear relationship between digital voxel intensities and the actual measured radioactive concentrations. Repeated printing together with WC measurements and computed radiography (CR) using phosphor imaging plates (IP) were used to evaluate the reproducibility and uniformity of such printing. Results show satisfactory printing uniformity and reproducibility; however, calibration is dependent on the printing mode and the physical state of the cartridge. As a demonstration of the utility of using printed phantoms, the image resolution and quantitative accuracy of reconstructed HRRT images are assessed. There is very good quantitative agreement in the calibration procedure between HRRT, CR and WC measurements. However, the high resolution of CR and its quantitative accuracy supported by WC measurements made it possible to show the degraded resolution of HRRT brain images caused by the partial-volume effect and the limits of iterative image reconstruction.
Xie, Lingling; Xu, Yuandong; Cao, Xiaoyu
2013-07-01
In this work, a highly sensitive hydrogen peroxide (H2O2) biosensor based on immobilization of hemoglobin (Hb) at Au nanoparticles (AuNPs)/flower-like zinc oxide/graphene (AuNPs/ZnO/Gr) composite modified glassy carbon electrode (GCE) was constructed, where ZnO and Au nanoparticles were modified through layer-by-layer onto Gr/GCE. Flower-like ZnO nanoparticles could be easily prepared by adding ethanol to the precursor solution having higher concentration of hydroxide ions. The Hb/AuNPs/ZnO/Gr composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E(0)) of -0.367 V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.3 s(-1). The developed biosensor showed a very fast response (<2 s) toward H2O2 with good sensitivity, wide linear range, and low detection limit of 0.8 μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of Gr, and good biocompatibility of ZnO and AuNPs. The fabrication method of this biosensor was simple and effective for determination of H2O2 in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery. Copyright © 2013 Elsevier B.V. All rights reserved.
Reproducibility of the vertical dimension of occlusion with an improved measuring gauge.
Morikawa, M; Kozono, Y; Noguchi, B S; Toyoda, S
1988-07-01
An improved gauge using an eyeglass frame, the TOM gauge, was devised. The reproducibility of the record of vertical dimension with this gauge was evaluated through repeated measurements on subjects having a definite centric stop with the natural dentition. Because of the stabilization provided by the frame and the reference point on the apex nasi, the TOM gauge showed excellent reproducibility of the record compared with the conventional gauges. The TOM gauge can be expected to significantly reduce the risk of errors in measuring the vertical dimension of occlusion especially in complete denture fabrication.
Manges, Amee R; Tellis, Patricia A; Vincent, Caroline; Lifeso, Kimberley; Geneau, Geneviève; Reid-Smith, Richard J; Boerlin, Patrick
2009-11-01
Discriminatory genotyping methods for the analysis of Escherichia coli other than O157:H7 are necessary for public health-related activities. A new multi-locus variable number tandem repeat analysis protocol is presented; this method achieves an index of discrimination of 99.5% and is reproducible and valid when tested on a collection of 836 diverse E. coli.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pollard, J; Prajapati, S; Gao, S
Purpose: To evaluate correlation between the reproducibility of tumor position under feedback guided voluntary deep inspiration breath hold gating at simulation and at treatment. Methods: All patients treated with breath hold (BH) have 3-6 BH CTs taken at simulation (sim). In addition, if the relationship between the tumor and nearby bony anatomy on treatment BH CT(or CBCT) is found to be greater than 5 mm different at treatment than it was at sim, a repeat BH CT is taken before treatment. We retrospectively analyzed the sim CTs for 19 patients who received BH SBRT lung treatments and had repeat BHmore » CT on treatment. We evaluated the reproducibility of the tumor position during the simulation CTs and compared this to the reproducibility of the tumor position on the repeat treatment CT with our in-house CT alignment software (CT-Assisted Targeting for Radiotherapy). Results: Comparing the tumor position for multiple simulation BH CTs, we calculated: maximum difference (max) = 0.69cm; average difference (x) = 0.28cm; standard deviation (σ) = 0.18cm. Comparing the repeat BH CBCTs on treatment days we calculated: max = 0.44cm; x = 0.16cm; σ = 0.22cm. We also found that for 95% of our BH cases, the absolute variation in tumor position within the same imaging day was within 5mm of the range at the time of simulation and treatment. We found that 75% of the BH cases had less residual tumor motion on treatment days than at simulation. Conclusion: This suggests that a GTV contour based upon the residual tumor motion in multiple BH datasets plus 2 mm margin should be sufficient to cover the full range of residual tumor motion on treatment days.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wohlgemuth, J.; Bokria, J.; Gu, X.
Polymeric encapsulation materials may a change size when processed at typical module lamination temperatures. The relief of residual strain, trapped during the manufacture of encapsulation sheet, can affect module performance and reliability. For example, displaced cells and interconnects threaten: cell fracture; broken interconnects (open circuits and ground faults); delamination at interfaces; and void formation. A standardized test for the characterization of change in linear dimensions of encapsulation sheet has been developed and verified. The IEC 62788-1-5 standard quantifies the maximum change in linear dimensions that may occur to allow for process control of size change. Developments incorporated into the Committeemore » Draft (CD) of the standard as well as the assessment of the repeatability and reproducibility of the test method are described here. No pass/fail criteria are given in the standard, rather a repeatable protocol to quantify the change in dimension is provided to aid those working with encapsulation. The round-robin experiment described here identified that the repeatability and reproducibility of measurements is on the order of 1%. Recent refinements to the test procedure to improve repeatability and reproducibility include: the use of a convection oven to improve the thermal equilibration time constant and its uniformity; well-defined measurement locations reduce the effects of sampling size -and location- relative to the specimen edges; a standardized sand substrate may be readily obtained to reduce friction that would otherwise complicate the results; specimen sampling is defined, so that material is examined at known sites across the width and length of rolls; and encapsulation should be examined at the manufacturer’s recommended processing temperature, except when a cross-linking reaction may limit the size change. EVA, for example, should be examined 100 °C, between its melt transition (occurring up to 80 °C) and the onset of cross-linking (often at 100 °C).« less
Sebbag, Lionel; Park, Shin Ae; Kass, Philip H; Maggs, David J; Attar, Mayssa; Murphy, Christopher J
2017-07-01
To evaluate repeatability and reproducibility of tear osmolarity measured using the TearLab ™ osmometer in normal dogs and to assess its diagnostic potential in dogs with keratoconjunctivitis sicca (KCS). Beagle dogs; six normal and five with KCS. Tear osmolarity and Schirmer tear test-1 (STT-1) values were obtained at various times. Normal dogs were assessed for diurnal variation and repeatability and reproducibility of measurements. Dogs with KCS were evaluated before and after 5 months' topical twice-daily therapy with 2% cyclosporine. Mean ± SD tear osmolarity (mOsm/L) was significantly higher in normal dogs (337.4 ± 16.2) than in dogs with KCS before therapy (306.2 ± 18.0; P < 0.0001), but not following therapy with 2% cyclosporine (330.5 ± 13.7; P = 1.00). Osmolarity readings lower than 325.5 mOsm/L were suggestive of KCS (84.8% sensitivity and 87.1% specificity). In normal dogs, tear osmolarity readings were stable during the daytime (P = 0.99). Repeated measurements revealed high variability and typically poor-to-moderate repeatability and reproducibility, although this was improved by taking three successive measurements at each session. Considering combined data from all dogs, a positive correlation existed between STT-1 and tear osmolarity measurements (Pearson's correlation test, P = 0.04, r = 0.62). Canine tear osmolarity as determined by TearLab ™ osmometer was variable, required multiple readings to be informative, and differed from values reported for humans. Dogs with KCS had a lower tear osmolarity than did normal dogs, and this increased following cyclosporine therapy. © 2016 American College of Veterinary Ophthalmologists.
Silva, P; Crozier, S; Veidt, M; Pearcy, M J
2005-07-01
A hydrogel intervertebral disc (IVD) model consisting of an inner nucleus core and an outer anulus ring was manufactured from 30 and 35% by weight Poly(vinyl alcohol) hydrogel (PVA-H) concentrations and subjected to axial compression in between saturated porous endplates at 200 N for 11 h, 30 min. Repeat experiments (n=4) on different samples (N=2) show good reproducibility of fluid loss and axial deformation. An axisymmetric nonlinear poroelastic finite element model with variable permeability was developed using commercial finite element software to compare axial deformation and predicted fluid loss with experimental data. The FE predictions indicate differential fluid loss similar to that of biological IVDs, with the nucleus losing more water than the anulus, and there is overall good agreement between experimental and finite element predicted fluid loss. The stress distribution pattern indicates important similarities with the biological IVD that includes stress transference from the nucleus to the anulus upon sustained loading and renders it suitable as a model that can be used in future studies to better understand the role of fluid and stress in biological IVDs.
Yang, Yinhui; Chang, Zhengfeng; Yang, Xiaohong; Qi, Meiling; Wang, Jinliang
2018-08-03
Herein we report a propeller-like hexaphenylbenzene-based hydrocarbon material (denoted as BT) as the stationary phase for capillary gas chromatography (GC). The statically-coated BT capillary column showed a high column efficiency of 4340 plates m -1 and weak polarity. Owing to its unique conformation, π-electron toroidal delocalization and intrinsic microporosity, the BT stationary phase exhibited interesting selectivity for aromatic compounds over alkanes. Compared with the graphene (G) column, the BT column showed much prolonged retention and high selectivity for aromatic isomers, especially methylnaphthalenes, dimethylnaphthalenes and phenanthrene/anthracene, mainly because of its propeller-like conformation with rich intercalation effects. Moreover, it exhibited good column repeatability (intra-day, inter-day) and reproducibility (between-column) with RSD values on the retention times less than 0.08% for intra-day, 0.32% for inter-day and 3.8% for between-column, respectively. Also, it showed good potential for determination of minor isomer impurities in real samples. To the best of our knowledge, this work presents the first example of employing an neat aromatic hydrocarbon material as the GC stationary phase with high selectivity for analytes of a wide ranging polarity. Copyright © 2018 Elsevier B.V. All rights reserved.
Brondani, Daniela; Scheeren, Carla Weber; Dupont, Jairton; Vieira, Iolanda Cruz
2012-08-21
Halloysite clay nanotubes were used as a support for the immobilization of the enzyme peroxidase from clover sprouts (Trifolium), and employed together with platinum nanoparticles in 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid (Pt-BMI·PF(6)) in the development of a new biosensor for the determination of catecholamines by square-wave voltammetry. Under optimized conditions, the analytical curves showed detection limits of 0.05, 0.06, 0.07, 0.12 μM for dopamine, isoproterenol, dobutamine and epinephrine, respectively. The biosensor demonstrated high sensitivity, good repeatability and reproducibility, and long-term stability (18% decrease in response over 150 days). A recovery study of dopamine in pharmaceutical samples gave values from 97.5 to 101.4%. The proposed biosensor was successfully applied to the determination of dopamine in pharmaceutical samples, with a maximum relative error of ±1.0% in relation to the standard (spectrophotometric) method. The good analytical performance of the proposed method can be attributed to the efficient immobilization of the peroxidase in the nanoclay, and the facilitation of electron transfer between the protein and the electrode surface due to the presence of the Pt nanoparticles and ionic liquid.
Determining a one-tailed upper limit for future sample relative reproducibility standard deviations.
McClure, Foster D; Lee, Jung K
2006-01-01
A formula was developed to determine a one-tailed 100p% upper limit for future sample percent relative reproducibility standard deviations (RSD(R),%= 100s(R)/y), where S(R) is the sample reproducibility standard deviation, which is the square root of a linear combination of the sample repeatability variance (s(r)2) plus the sample laboratory-to-laboratory variance (s(L)2), i.e., S(R) = s(L)2, and y is the sample mean. The future RSD(R),% is expected to arise from a population of potential RSD(R),% values whose true mean is zeta(R),% = 100sigmaR, where sigmaR and mu are the population reproducibility standard deviation and mean, respectively.
Schroeder, J; Reer, R; Braumann, K M
2015-02-01
As reliability of raster stereography was proved only for sagittal plane parameters with repeated measures on the same day, the present study was aiming at investigating variability and reliability of back shape reconstruction for all dimensions (sagittal, frontal, transversal) and for different intervals. For a sample of 20 healthy volunteers, intra-individual variability (SEM and CV%) and reliability (ICC ± 95% CI) were proved for sagittal (thoracic kyphosis, lumbar lordosis, pelvis tilt angle, and trunk inclination), frontal (pelvis torsion, pelvis and trunk imbalance, vertebral side deviation, and scoliosis angle), transversal (vertebral rotation), and functional (hyperextension) spine shape reconstruction parameters for different test-retest intervals (on the same day, between-day, between-week) by means of video raster stereography. Reliability was high for the sagittal plane (pelvis tilt, kyphosis and lordosis angle, and trunk inclination: ICC > 0.90), and good to high for lumbar mobility (0.86 < ICC < 0.97). Apart from sagittal plane spinal alignment, there was a lack of certainty for a high reproducibility indicated by wider ICC confidence intervals. So, reliability was fair to high for vertebral side deviation and the scoliosis angle (0.71 < ICC < 0.95), and poor to good for vertebral rotation values as well as for frontal plane upper body and pelvis position parameters (0.65 < ICC < 0.92). Coefficients for the between-day and between-week interval were a little lower than for repeated measures on the same day. Variability (SEM) was less than 1.5° or 1.5 mm, except for trunk inclination. Relative variability (CV) was greater in global trunk position and pelvis parameters (35-98%) than in scoliosis (14-20%) or sagittal sway parameters (4-8 %). Although we found a lower reproducibility for the frontal plane, raster stereography is considered to be a reliable method for the non-invasive, three-dimensional assessment of spinal alignment in normal non-scoliotic individuals in the sagittal plane and partly for scoliosis parameters, which fulfils scientific as well as practical recommendations for spine shape screening and monitoring, but cross-sectional or follow-up effect analyses should take into account the degree of reliability differing in various spine shape parameters. Further investigations should be conducted to analyse reliability in scoliosis patients with differing spinal deformities.
Enhancing separation in short-capillary electrophoresis via pressure-driven backflow.
Tian, Miaomiao; Wang, Yujia; Mohamed, Amara Camara; Guo, Liping; Yang, Li
2015-07-01
We present a novel easy-to-operate and efficient method to improve the separation efficiency in short-capillary electrophoresis by introducing steady backflow to counterbalance electro-osmotic flow without the use of any external pressure. The backflow was easily generated by tapering the capillary end, which was achieved by heating a straight capillary and stretching it with a constant force. We investigated the net fluidic transport rate under different tip lengths and separation voltages. Good run-to-run repeatability and capillary-to-capillary reproducibility of the present method were obtained with RSD less than 1.5%, indicating the stability of the fluid transport rate in the tapered capillary, which ensures the quantification and repeatability of capillary zone electrophoresis (CZE) analysis. Enhanced separation of the tapered short capillary electrophoresis was demonstrated by CZE analyzing amino acids and positional isomers. Baseline separations were achieved in less than 60 s using a tapered capillary with the effective length of 5 cm, while no separation was achieved using a normal capillary without a tapered tip. The present study provides a promising method to use pressure-driven backflow to enhance separation efficiency in short-capillary electrophoresis, which would be of potential value in a wide application for fast analysis of complex samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Nomura, N; Saito, K; Ikeda, M; Yuasa, S; Pastore, M; Chabert, C; Kono, E; Sakai, A; Tanaka, H; Ikemoto, T; Takubo, T
2015-08-01
We evaluated the basic performance of Microsemi CRP, an unique automated hematology analyzer which can simultaneously measure CBC including 3-part WBC differential (3-Diff) and CRP using whole blood treated with EDTA-2K anticoagulant. We found that it produced generally the acceptable results for all parameters performed (repeatability, reproducibility, linearity, interference effect, carry over, and correlation) using control materials, fresh human whole bloods, and serum samples. CBC data examined using Microsemi CRP showed the good correlation with the previous model, Micros CRP200 (r ≧ 0.9), and also those obtained using the routine analyzer, ADVIA 2120i (r ≧ 0.989). Concerning the 3-Diff, both GRA (%) and LYM (%) showed the excellent correlation coefficient between Microsemi CRP and Micros CRP200 (r ≧ 0.992) as well as ADVIA 2120i (r ≧ 0.957). MON (%) showed good correlation between Microsemi CRP and Micros CRP200 (r = 0.959), but lower correlation between Microsemi CRP and ADVIA 2120 i (r = 0.471). CRP data showed the good correlation with HITACHI7600 (r ≧ 0.997) and Micros CRP200 (r ≧ 0.997). From these findings, we concluded that Microsemi CRP seemed the convenient laboratory analyzer in the setting of point of care testing (POCT) especially at NICU or primary care unit. © 2014 John Wiley & Sons Ltd.
Momenbeik, Fariborz; Yazdani, Elham
2015-01-01
Methyl silane coated Fe3O4 magnetic nanoparticles were used for simultaneous extraction of the fat-soluble vitamins (FSVs). The amounts of extracted vitamins were determined by HPLC. The synthesized Fe3O4 nanoparticles were coated with silica and then modified with trimethoxymethylsilane (TMMS). The prepared particles were characterized by different methods. The best amounts of silica and TMMS in sorbent synthesis were 1.2 and 0.5 mL, respectively. The optimum pH values for the sample solution and washing buffer were 5 and 3, respectively. Application of 100 mg sorbent, 700 μL tetrahydrofuran, 5-fold dilution of the sample solution, and 1 min for sorption and desorption times were among the best conditions. At the optimum conditions, the calibration plots for each vitamin were obtained with good linearity (R(2) >0.9992) and suitable linear ranges. This method has a low LOD (<76.1 μg/mL), acceptable repeatability (RSD <5.63%) and reproducibility (RSD <4.71%), and good accuracy (recovery >90.3%). Preconcentration of low concentrations of vitamin D3 was performed, and results showed 3.7 times greater sensitivity after preconcentration. Finally, the amounts of the FSVs in pharmaceutical formulations were determined using the proposed method, and results showed good agreement with those reported by manufacturers.
Zinc oxide crystal whiskers as a novel sorbent for solid-phase extraction of flavonoids.
Wang, Licheng; Shangguan, Yangnan; Hou, Xiudan; Jia, Yong; Liu, Shujuan; Sun, Yingxin; Guo, Yong
2017-08-15
As a novel solid-phase extraction material, zinc oxide crystal whiskers were used to extract flavonoid compounds and showed good extraction abilities. X-ray diffraction, scanning electron microscopy with energy dispersive X-ray spectroscopy and surface area/pore volume characterized the sorbent. The zinc oxide was packed into a solid-phase extraction micro-column and its extraction ability was evaluated by four model flavonoid compounds. The sample loading and elution parameters were optimized and the zinc oxide based analytical method for flavonoids was established. It showed that the method has wide linearities from 1 to 150μg/L and low limits of detection at 0.25μg/L. The relative standard deviations of a single column repeatability and column to column reproducibility were less than 6.8% and 10.6%. Several real samples were analyzed by the established method and satisfactory results were obtained. The interactions between flavonoids and zinc oxide were calculated and proved to be from the Van der Waals' forces between the 4p and 5d orbitals from zinc atom and the neighboring π orbitals from flavonoid phenyl groups. Moreover, the zinc oxide crystal whiskers showed good stability and could be reused more than 50 times under the operation conditions. This work proves that the zinc oxide crystal whiskers are a good candidate for flavonoids enrichment. Copyright © 2017. Published by Elsevier B.V.
Wang, Fuxin; Liu, Shuqin; Yang, Hao; Zheng, Juan; Qiu, Junlang; Xu, Jianqiao; Tong, Yexiang; Zhu, Fang; Ouyang, Gangfeng
2016-11-01
Graphene, a novel class of carbon nanostructures, has received great attention as sorbents due to its fascinating structures, ultrahigh specific surface area, and good extraction ability. In this paper, a new type of hierarchical graphene was synthesized through employing a mild and environment-friendly method. Such 3D interconnected graphene own a high specific surface area up to 524m(2)g(-1), which is about 2.5 fold larger than the graphene, since the synthetic material has interlayer pores between nanosheets and in-plane pores. Then a superior solid-phase microextraction fiber was fabricated by sequentially coating the stainless steel fiber with silicone sealant film and hierarchical graphene powder. Since the novel hierarchical graphene possessed large surface area and good adsorption property, the as-prepared fiber exhibited good extraction properties of the organochlorine pesticides (OCPs). As for the analytical performance, the as-prepared fiber achieved low detection limits (0.08-0.80ngL(-1)) and wide linearity (10-30,000ngL(-1)) under the optimal conditions. The repeatability (n=5) for single fiber were between 5.1% and 11%, while the reproducibility (n=3) of fiber-to-fiber were range from 6.2% to14%. Moreover, the fiber was successfully applied to the analysis of OCPs in the Pearl River water. Copyright © 2016 Elsevier B.V. All rights reserved.
Odor measurements according to EN 13725: A statistical analysis of variance components
NASA Astrophysics Data System (ADS)
Klarenbeek, Johannes V.; Ogink, Nico W. M.; van der Voet, Hilko
2014-04-01
In Europe, dynamic olfactometry, as described by the European standard EN 13725, has become the preferred method for evaluating odor emissions emanating from industrial and agricultural sources. Key elements of this standard are the quality criteria for trueness and precision (repeatability). Both are linked to standard values of n-butanol in nitrogen. It is assumed in this standard that whenever a laboratory complies with the overall sensory quality criteria for n-butanol, the quality level is transferable to other, environmental, odors. Although olfactometry is well established, little has been done to investigate inter laboratory variance (reproducibility). Therefore, the objective of this study was to estimate the reproducibility of odor laboratories complying with EN 13725 as well as to investigate the transferability of n-butanol quality criteria to other odorants. Based upon the statistical analysis of 412 odor measurements on 33 sources, distributed in 10 proficiency tests, it was established that laboratory, panel and panel session are components of variance that significantly differ between n-butanol and other odorants (α = 0.05). This finding does not support the transferability of the quality criteria, as determined on n-butanol, to other odorants and as such is a cause for reconsideration of the present single reference odorant as laid down in EN 13725. In case of non-butanol odorants, repeatability standard deviation (sr) and reproducibility standard deviation (sR) were calculated to be 0.108 and 0.282 respectively (log base-10). The latter implies that the difference between two consecutive single measurements, performed on the same testing material by two or more laboratories under reproducibility conditions, will not be larger than a factor 6.3 in 95% of cases. As far as n-butanol odorants are concerned, it was found that the present repeatability standard deviation (sr = 0.108) compares favorably to that of EN 13725 (sr = 0.172). It is therefore suggested that the repeatability limit (r), as laid down in EN 13725, can be reduced from r ≤ 0.477 to r ≤ 0.31.
Maillot, C; Ferrero, E; Fort, D; Heyberger, C; Le Huec, J-C
2015-07-01
The purpose of this study was to evaluate the inter- and intra-observer variability of the computerized radiologic measurements using Keops(®) and to determine the bias between the software and the standard paper measurement. Four individuals measured all frontal and sagittal variables on the 30 X-rays randomly selected on two occasions (test and retest conditions). The Bland-Altman plot was used to determine the degree of agreement between the measurement on paper X-ray and the measurement using Keops(®) for all reviewers and for the two measures; the intraclass correlation coefficient (ICC) was calculated for each pair of analyses to assess interobserver reproducibility among the four reviewers for the same patient using either paper X-ray or Keops(®) measurement and finally, concordance correlation coefficient (rc) was calculated to assess intraobserver repeatability among the same reviewer for one patient between the two measure using the same method (paper or Keops(®)). The mean difference calculated between the two methods was minimal at -0, 4° ± 3.41° [-7.1; 6.4] for frontal measurement and 0.1° ± 3.52° [-6.7; 6.8] for sagittal measurement. Keops(®) has a better interobserver reproducibility than paper measurement for determination of the sagittal pelvic parameter (ICC = 0.9960 vs. 0.9931; p = 0.0001). It has a better intraobserver repeatability than paper for determination of Cobbs angle (rc = 0.9872 vs. 0.9808; p < 0.0001) and for pelvic parameter (rc = 0.9981 vs. 0.9953; p < 0.0001). We conclude that Keops(®) has no bias compared to the traditionally paper measurement, and moreover, the repeatability and the reproducibility of measurements with this method is much better than with similar standard radiologic measures done manually in both frontal and sagittal plane and that the use of this software can be recommended for clinical application. Diagnostic, level III.
Reproducibility of regional DEXA examinations of abdominal fat and lean tissue.
Tallroth, Kaj; Kettunen, Jyrki A; Kujala, Urho M
2013-01-01
The aim of this study was to develop and test the validity of a new repeatable method to delimit abdominal areas for follow-up of fat mass (FM) and lean tissue mass (LM) in DEXA examinations. 37 male volunteers underwent two DEXA examinations. Total body FM and LM measurements and corresponding abdominal measurements in a carefully defined region were calculated from the first scan. After repositioning of the subjects and a second scan, the delimited region was copied and the abdominal tissues re-calculated. The mean LM of the abdominal area was 2.804 kg (SD 0.556), and the mean FM was 1.026 kg (SD 0.537). The intra-class correlation coefficient for the repeated abdominal LM, FM, and LM/FM ratio measurements was 0.99. The mean difference (bias) for the repeated abdominal LM measurements was -13 g (95% confidence interval (CI) -193.0 to 166.8), and for the repeated abdominal FM measurements it was -35 g (95% CI -178.9 to 108.5). The results indicate that regional DEXA is a sensitive method with excellent reproducibility in the measurements of the abdominal fat and lean tissues. The method may serve as a useful tool for evaluation and follow-up of various dietary and training programmes.
Reproducibility of Regional DEXA Examinations of Abdominal Fat and Lean Tissue
Tallroth, Kaj; Kettunen, Jyrki A.; Kujala, Urho M.
2013-01-01
Objective The aim of this study was to develop and test the validity of a new repeatable method to delimit abdominal areas for follow-up of fat mass (FM) and lean tissue mass (LM) in DEXA examinations. Methods 37 male volunteers underwent two DEXA examinations. Total body FM and LM measurements and corresponding abdominal measurements in a carefully defined region were calculated from the first scan. After repositioning of the subjects and a second scan, the delimited region was copied and the abdominal tissues re-calculated. Results The mean LM of the abdominal area was 2.804 kg (SD 0.556), and the mean FM was 1.026 kg (SD 0.537). The intra-class correlation coefficient for the repeated abdominal LM, FM, and LM/FM ratio measurements was 0.99. The mean difference (bias) for the repeated abdominal LM measurements was −13 g (95% confidence interval (CI) −193.0 to 166.8), and for the repeated abdominal FM measurements it was −35 g (95% CI −178.9 to 108.5). Conclusions The results indicate that regional DEXA is a sensitive method with excellent reproducibility in the measurements of the abdominal fat and lean tissues. The method may serve as a useful tool for evaluation and follow-up of various dietary and training programmes. PMID:23615566
ERIC Educational Resources Information Center
van Gorp, Karly; Segers, Eliane; Verhoeven, Ludo
2017-01-01
The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed by a transfer task with a different set of items.…
Genotypic variability enhances the reproducibility of an ecological study.
Milcu, Alexandru; Puga-Freitas, Ruben; Ellison, Aaron M; Blouin, Manuel; Scheu, Stefan; Freschet, Grégoire T; Rose, Laura; Barot, Sebastien; Cesarz, Simone; Eisenhauer, Nico; Girin, Thomas; Assandri, Davide; Bonkowski, Michael; Buchmann, Nina; Butenschoen, Olaf; Devidal, Sebastien; Gleixner, Gerd; Gessler, Arthur; Gigon, Agnès; Greiner, Anna; Grignani, Carlo; Hansart, Amandine; Kayler, Zachary; Lange, Markus; Lata, Jean-Christophe; Le Galliard, Jean-François; Lukac, Martin; Mannerheim, Neringa; Müller, Marina E H; Pando, Anne; Rotter, Paula; Scherer-Lorenzen, Michael; Seyhun, Rahme; Urban-Mead, Katherine; Weigelt, Alexandra; Zavattaro, Laura; Roy, Jacques
2018-02-01
Many scientific disciplines are currently experiencing a 'reproducibility crisis' because numerous scientific findings cannot be repeated consistently. A novel but controversial hypothesis postulates that stringent levels of environmental and biotic standardization in experimental studies reduce reproducibility by amplifying the impacts of laboratory-specific environmental factors not accounted for in study designs. A corollary to this hypothesis is that a deliberate introduction of controlled systematic variability (CSV) in experimental designs may lead to increased reproducibility. To test this hypothesis, we had 14 European laboratories run a simple microcosm experiment using grass (Brachypodium distachyon L.) monocultures and grass and legume (Medicago truncatula Gaertn.) mixtures. Each laboratory introduced environmental and genotypic CSV within and among replicated microcosms established in either growth chambers (with stringent control of environmental conditions) or glasshouses (with more variable environmental conditions). The introduction of genotypic CSV led to 18% lower among-laboratory variability in growth chambers, indicating increased reproducibility, but had no significant effect in glasshouses where reproducibility was generally lower. Environmental CSV had little effect on reproducibility. Although there are multiple causes for the 'reproducibility crisis', deliberately including genetic variability may be a simple solution for increasing the reproducibility of ecological studies performed under stringently controlled environmental conditions.
Liu, Boyang; Dardeer, Ahmed M; Moody, William E; Edwards, Nicola C; Hudsmith, Lucy E; Steeds, Richard P
2018-02-01
Reproducible and repeatable assessment of right heart function is vital for monitoring congenital and acquired heart disease. There is increasing evidence for the additional value of myocardial deformation (strain and strain rate) in determining prognosis. This study aims to determine the reproducibility of deformation analyses in the right heart using cardiovascular magnetic resonance feature tracking (FT-CMR); and to establish normal ranges within an adult population. A cohort of 100 healthy subjects containing 10 males and 10 females from each decade of life between the ages of 20 and 70 without known congenital or acquired cardiovascular disease, hypertension, diabetes, dyslipidaemia or renal, hepatic, haematologic and systemic inflammatory disorders underwent FT-CMR assessment of right ventricular (RV) and right atrial (RA) myocardial strain and strain rate. RV longitudinal strain (Ell) was -21.9±3.24% (FW+S Ell) and -24.2±3.59% (FW-Ell). Peak systolic strain rate (S') was -1.45±0.39s -1 (FW+S) and -1.54±0.41s -1 (FW). Early diastolic strain rate (E') was 1.04±0.26s -1 (FW+S) and 1.04±0.33s -1 (FW). Late diastolic strain rate (A') was 0.94±0.33s -1 (FW+S) and 1.08±0.33s -1 (FW). RA peak strain was -21.1±3.76%. The intra- and inter-observer ICC for RV Ell (FW+S) was 0.92 and 0.80 respectively, while for RA peak strain was 0.92 and 0.89 respectively. Normal values of RV & RA deformation for healthy individuals using FT-CMR are provided with good RV Ell and RA peak strain reproducibility. Strain rate suffered from sub-optimal reproducibility and may not be satisfactory for clinical use. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Burghardt, Andrew J.; Buie, Helen R.; Laib, Andres; Majumdar, Sharmila; Boyd, Steven K.
2010-01-01
Quantitative cortical micro-architectural endpoints are important for understanding structure-function relations in the context of fracture risk and therapeutic efficacy. This technique study details new image-processing methods to automatically segment and directly quantify cortical density, geometry, and micro-architecture from HR-pQCT images of the distal radius and tibia. An automated segmentation technique was developed to identify the periosteal and endosteal margins of the distal radius and tibia, and detect intra-cortical pore space morphologically consistent with Haversian canals. The reproducibility of direct quantitative cortical bone indices based on this method was assessed in a pooled dataset of 56 subjects with two repeat acquisitions for each site. The in vivo precision error was characterized using root mean square coefficient of variation (RMSCV%) from which, the least significant change (LSC) was calculated. Bland-Altman plots were used to characterize bias in the precision estimates. The reproducibility of cortical density and cross-sectional area measures was high (RMSCV <1% and <1.5%, respectively) with good agreement between young and elder medians. The LSC for cortical porosity (Ct.Po) was somewhat smaller in the radius (0.58%) compared with the distal tibia (0.84%) and significantly different between young and elder medians in the distal tibia (LSC: 0.75% vs. 0.92%; p<0.001). The LSC for pore diameter and distribution (Po.Dm and Po.Dm.SD) ranged between 15 and 23μm. Bland-Altman analysis revealed moderate bias for integral measures of area and volume, but not density nor microarchitecture. This study indicates HR-pQCT measures of cortical bone density and architecture can be measured in vivo with high reproducibility and limited bias across a biologically relevant range of values. The results of this study provide informative data for the design of future clinical studies of bone quality. PMID:20561906
Repeatability and reproducibility of ribotyping and its computer interpretation.
Lefresne, Gwénola; Latrille, Eric; Irlinger, Françoise; Grimont, Patrick A D
2004-04-01
Many molecular typing methods are difficult to interpret because their repeatability (within-laboratory variance) and reproducibility (between-laboratory variance) have not been thoroughly studied. In the present work, ribotyping of coryneform bacteria was the basis of a study involving within-gel and between-gel repeatability and between-laboratory reproducibility (two laboratories involved). The effect of different technical protocols, different algorithms, and different software for fragment size determination was studied. Analysis of variance (ANOVA) showed, within a laboratory, that there was no significant added variance between gels. However, between-laboratory variance was significantly higher than within-laboratory variance. This may be due to the use of different protocols. An experimental function was calculated to transform the data and make them compatible (i.e., erase the between-laboratory variance). The use of different interpolation algorithms (spline, Schaffer and Sederoff) was a significant source of variation in one laboratory only. The use of either Taxotron (Institut Pasteur) or GelCompar (Applied Maths) was not a significant source of added variation when the same algorithm (spline) was used. However, the use of Bio-Gene (Vilber Lourmat) dramatically increased the error (within laboratory, within gel) in one laboratory, while decreasing the error in the other laboratory; this might be due to automatic normalization attempts. These results were taken into account for building a database and performing automatic pattern identification using Taxotron. Conversion of the data considerably improved the identification of patterns irrespective of the laboratory in which the data were obtained.
Kolich, Mike
2009-04-01
This article describes a new and more repeatable, reproducible, and valid test method for characterizing lumbar support in automotive seating. Lumbar support is important because it affects occupant accommodation and perceptions of seat comfort. Assessing only the lumbar mechanism--particularly in terms of travel--is inadequate because it does not consider the effects of trim and foam. The Society of Automotive Engineers' next-generation H-Point machine and associated loading protocol were used as the basis for the new test. The method was found to satisfy minimum gage repeatability and reproducibility requirements. Validity was demonstrated through a regression model that revealed 93.9% of the variance in subjective ratings of poor uncomfortable lumbar support can be explained by two objective indicators: (1) lumbar support prominence in the full-off position and (2) effective travel. The method can be used to differentiate between seats offering two-way adjustable lumbar support. The best two-way adjustable lumbar seat systems are those that couple little to no lumbar support in the starting or off position (i.e., they are nonintrusive) with a considerable amount of effective or perceptible travel. The automotive industry has long needed a way to address the fact that consumers want more lumbar support than their seats currently supply. This contribution offers a method to objectify an important aspect of automotive seating comfort-namely, lumbar support. This should help human factors professionals produce, but not necessarily guarantee, better consumer ratings.
Jovicich, Jorge; Marizzoni, Moira; Bosch, Beatriz; Bartrés-Faz, David; Arnold, Jennifer; Benninghoff, Jens; Wiltfang, Jens; Roccatagliata, Luca; Picco, Agnese; Nobili, Flavio; Blin, Oliver; Bombois, Stephanie; Lopes, Renaud; Bordet, Régis; Chanoine, Valérie; Ranjeva, Jean-Philippe; Didic, Mira; Gros-Dagnac, Hélène; Payoux, Pierre; Zoccatelli, Giada; Alessandrini, Franco; Beltramello, Alberto; Bargalló, Núria; Ferretti, Antonio; Caulo, Massimo; Aiello, Marco; Ragucci, Monica; Soricelli, Andrea; Salvadori, Nicola; Tarducci, Roberto; Floridi, Piero; Tsolaki, Magda; Constantinidis, Manos; Drevelegas, Antonios; Rossini, Paolo Maria; Marra, Camillo; Otto, Josephin; Reiss-Zimmermann, Martin; Hoffmann, Karl-Titus; Galluzzi, Samantha; Frisoni, Giovanni B
2014-11-01
Large-scale longitudinal neuroimaging studies with diffusion imaging techniques are necessary to test and validate models of white matter neurophysiological processes that change in time, both in healthy and diseased brains. The predictive power of such longitudinal models will always be limited by the reproducibility of repeated measures acquired during different sessions. At present, there is limited quantitative knowledge about the across-session reproducibility of standard diffusion metrics in 3T multi-centric studies on subjects in stable conditions, in particular when using tract based spatial statistics and with elderly people. In this study we implemented a multi-site brain diffusion protocol in 10 clinical 3T MRI sites distributed across 4 countries in Europe (Italy, Germany, France and Greece) using vendor provided sequences from Siemens (Allegra, Trio Tim, Verio, Skyra, Biograph mMR), Philips (Achieva) and GE (HDxt) scanners. We acquired DTI data (2 × 2 × 2 mm(3), b = 700 s/mm(2), 5 b0 and 30 diffusion weighted volumes) of a group of healthy stable elderly subjects (5 subjects per site) in two separate sessions at least a week apart. For each subject and session four scalar diffusion metrics were considered: fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD) and axial (AD) diffusivity. The diffusion metrics from multiple subjects and sessions at each site were aligned to their common white matter skeleton using tract-based spatial statistics. The reproducibility at each MRI site was examined by looking at group averages of absolute changes relative to the mean (%) on various parameters: i) reproducibility of the signal-to-noise ratio (SNR) of the b0 images in centrum semiovale, ii) full brain test-retest differences of the diffusion metric maps on the white matter skeleton, iii) reproducibility of the diffusion metrics on atlas-based white matter ROIs on the white matter skeleton. Despite the differences of MRI scanner configurations across sites (vendors, models, RF coils and acquisition sequences) we found good and consistent test-retest reproducibility. White matter b0 SNR reproducibility was on average 7 ± 1% with no significant MRI site effects. Whole brain analysis resulted in no significant test-retest differences at any of the sites with any of the DTI metrics. The atlas-based ROI analysis showed that the mean reproducibility errors largely remained in the 2-4% range for FA and AD and 2-6% for MD and RD, averaged across ROIs. Our results show reproducibility values comparable to those reported in studies using a smaller number of MRI scanners, slightly different DTI protocols and mostly younger populations. We therefore show that the acquisition and analysis protocols used are appropriate for multi-site experimental scenarios. Copyright © 2014 Elsevier Inc. All rights reserved.
Blanchet-Réthoré, Sandrine; Bourdès, Valérie; Mercenier, Annick; Haddar, Cyrille H; Verhoeven, Paul O; Andres, Philippe
2017-01-01
Staphylococcus aureus dominates the skin microbiota in patients with atopic dermatitis (AD), with bacterial loads correlating with disease severity. The aim of this exploratory study was to investigate the effect of a cosmetic lotion containing heat-treated Lactobacillus johnsonii NCC 533 (HT La1) on S. aureus colonization in AD patients. This open-label, multicenter study was performed in AD patients in Germany. First, detection of S. aureus was performed in all patients using the swab or scrub-wash method of sampling, followed by quantitative culture or quantitative polymerase chain reaction. Repeatability and reproducibility of all method combinations were evaluated to select the best combination of sampling and quantification. Second, a lotion containing HT La1 was applied to lesional skin twice daily for 3 weeks. Scoring using local objective SCORing Atopic Dermatitis (SCORAD), measurement of S. aureus load, and lesional microbiome analysis were performed before and after the 3-week treatment period. Thirty-one patients with AD were included in the study. All sampling and quantification methods were found to be robust, reproducible, and repeatable for assessing S. aureus load. For simplicity, a combination of swab and quantitative polymerase chain reaction was chosen to assess the efficacy of HT La1. Following application of a lotion containing HT La1 to AD lesions for 3 weeks, a reduction in S. aureus load was observed in patients, which correlated with a decrease in local objective SCORAD. Interestingly, high baseline skin concentrations of S. aureus were associated with good responses to the lotion. This study demonstrated that the application of a lotion containing HT La1 to the lesional skin of patients with AD for 3 weeks controlled S. aureus colonization and was associated with local clinical improvement (SCORAD). These findings support further development of topical treatments containing heat-treated nonreplicating beneficial bacteria for patients with AD.
Quantitative evaluation of pancreatic tumor fibrosis using shear wave elastography.
Kuwahara, Takamichi; Hirooka, Yoshiki; Kawashima, Hiroki; Ohno, Eizaburo; Sugimoto, Hiroyuki; Hayashi, Daijuro; Morishima, Tomomasa; Kawai, Manabu; Suhara, Hiroki; Takeyama, Tomoaki; Yamamura, Takeshi; Funasaka, Kohei; Nakamura, Masanao; Miyahara, Ryoji; Watanabe, Osamu; Ishigami, Masatoshi; Shimoyama, Yoshie; Nakamura, Shigeo; Hashimoto, Senju; Goto, Hidemi
There is no established non-invasive method for diagnosis of pancreatic fibrosis. Shear wave elastography (SW-EG) may be a candidate for this purpose. The aims of this study were to assess the reproducibility of SW-EG in the normal imaging pancreas (Phase 1) and to evaluate the diagnostic performance of SW-EG for pancreatic fibrosis classified histologically (Phase 2). Phase 1: This included 127 cases that underwent SW-EG of the normal imaging pancreas. SW-EG was measured at least five times in the pancreatic parenchyma and the median of repeated measurements was defined as the pancreatic elastic modulus (PEM). Phase 2: This included 53 cases that underwent SW-EG of the pancreatic parenchyma preoperatively and in which pancreas parenchyma were evaluated histologically. Histological fibrosis was graded in 4 stages: normal, mild, moderate, and severe. Phase 1: Median PEM in the head, body, and tail of the pancreas were 3.23, 3.17, and 2.91 kPa, respectively, with no significant difference among regions (P = 0.554). The intraclass correlation coefficient showed good reproducibility (ρ = 0.71) after 5 measurements. Phase 2: There was a significant positive correlation between PEM and the histological pancreatic fibrosis stage (r s = 0.63, P < 0.001). Areas under the receiver operating characteristic curve for the accuracy of SW-EG for diagnosis of pancreatic fibrosis were 0.85 (≥mild), 0.84 (≥moderate), and 0.87 (severe). SW-EG can be used to determine the stage of pancreatic fibrosis non-invasively with high accuracy and reproducibility. Copyright © 2016 IAP and EPC. Published by Elsevier B.V. All rights reserved.
Shoji, Takuhei; Kato, Naoko; Ishikawa, Sho; Ibuki, Hisashi; Yamada, Norihiro; Kimura, Itaru; Shinoda, Kei
2017-01-01
To evaluate the reproducibility of in vivo crystalline lens measurements obtained by novel commercially available swept-source (SS) optical coherence tomography (OCT) specifically designed for anterior segment imaging. One eye from each of 30 healthy subjects was randomly selected using the CASIA2 (Tomey, Nagoya, Japan) in two separate visits within a week. Each eye was imaged twice. After image scanning, the anterior and posterior lens curvatures and lens thickness were calculated automatically by the CASIA2 built-in program at 0 dioptre (D) (static), -1 D, -3 D and -5 D accommodative stress. The intraobserver and intervisit reproducibility coefficient (RC) and intraclass correlation coefficient (ICC) were calculated. The intraobserver and intervisit RCs ranged from 0.824 to 1.254 mm and 0.789 to 0.911 mm for anterior lens curvature, from 0.276 to 0.299 mm and 0.221 to 0.270 mm for posterior lens curvature and from 0.065 to 0.094 mm and 0.054 to 0.132 mm for lens thickness, respectively. The intraobserver and intervisit ICCs ranged from 0.831 to 0.865 and 0.828 to 0.914 for anterior lens curvature, from 0.832 to 0.898 and 0.840 to 0.933 for posterior lens curvature and from 0.980 to 0.992 and 0.942 to 0.995 for lens thickness. High ICC values were observed for each measurement regardless of accommodative stress. RCs in younger subjects tended to be larger than those in older subjects. This novel anterior segment SS-OCT instrument produced reliable in vivo crystalline lens measurement with good repeatability and reproducibility regardless of accommodation stress.
Aerobic Stimulus Induced by Virtual Reality Games in Stroke Survivors.
Silva de Sousa, Julio Cesar; Torriani-Pasin, Camila; Tosi, Amanda Barboza; Fecchio, Rafael Yokoyama; Costa, Luiz Augusto Riani; Forjaz, Cláudia Lúcia de Moraes
2018-05-01
To evaluate whether virtual reality games (VRGs) in stroke survivors produce significant and reproducible heart rate and oxygen consumption (V˙o 2 ) responses during their execution, corresponding to an intensity between the anaerobic threshold (AT) and the respiratory compensation point (RCP). Single-subject, repeated-measure design. Stroke survivors registered from a rehabilitation program. Chronic hemiparetic stroke survivors (N=12; 10 men; mean age ± SD, 58±12y) rated at 3 or 4 in the Functional Ambulation Categories. Participants underwent, in a random order, 2 identical sessions of VRGs (console Xbox 360 + Kinect) and 1 control session (38min watching a movie). The VRG sessions were composed of 4 sets of VRGs (3min of tennis, 1min for changing the game, and 4min of boxing) interspaced with 2 minutes of rest. Heart rate and V˙o 2 were measured during the experimental sessions and compared with heart rate and V˙o 2 obtained at AT and RCP assessed during a maximal cardiopulmonary exercise test. Heart rate and V˙o 2 during VRGs had good reproducibility (intraclass correlation coefficients, ≥.91 and ≥.85, respectively; coefficients of variation, ≤6.7% and ≤13.7%, respectively). Heart rate during VRGs was similar to AT and significantly lower than RCP (P≤.05), while V˙o 2 was significantly lower than AT and RCP (P<.05). An acute session of VRGs composed of tennis and boxing games using the console XBox 360 + Kinect promotes reproducible responses of heart rate and V˙o 2 that corresponded, respectively, to AT and below AT, characterizing a low-intensity aerobic stimulus. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Reproducibility of the six-minute walking test in chronic heart failure patients.
Pinna, G D; Opasich, C; Mazza, A; Tangenti, A; Maestri, R; Sanarico, M
2000-11-30
The six-minute walking test (WT) is used in trials and clinical practice as an easy tool to evaluate the functional capacity of chronic heart failure (CHF) patients. As WT measurements are highly variable both between and within individuals, this study aims at assessing the contribution of the different sources of variation and estimating the reproducibility of the test. A statistical model describing WT measurements as a function of fixed and random effects is proposed and its parameters estimated. We considered 202 stable CHF patients who performed two baseline WTs separated by a 30 minute rest; 49 of them repeated the two tests 3 months later (follow-up control). They had no changes in therapy or major clinical events. Another 31 subjects performed two baseline tests separated by 24 hours. Collected data were analysed using a mixed model methodology. There was no significant difference between measurements taken 30 minutes and 24 hours apart (p = 0.99). A trend effect of 17 (1.4) m (mean (SE)) was consistently found between duplicate tests (p < 0.001). REML estimates of variance components were: 5189 (674) for subject differences in the error-free value; 1280 (304) for subject differences in spontaneous clinical evolution between baseline and follow-up control, and 266 (23) for the within-subject error. Hence, the standard error of measurement was 16.3 m, namely 4 per cent of the average WT performance (403 m) in this sample. The intraclass correlation coefficient was 0.96. We conclude that WT measurements are characterized by good intrasubject reproducibility and excellent reliability. When follow-up studies > or = 3 months are performed, unpredictable changes in individual walking performance due to spontaneous clinical evolution are to be expected. Their clinical significance, however, is not known. Copyright 2000 John Wiley & Sons, Ltd.
Statistical Validation of Image Segmentation Quality Based on a Spatial Overlap Index1
Zou, Kelly H.; Warfield, Simon K.; Bharatha, Aditya; Tempany, Clare M.C.; Kaus, Michael R.; Haker, Steven J.; Wells, William M.; Jolesz, Ferenc A.; Kikinis, Ron
2005-01-01
Rationale and Objectives To examine a statistical validation method based on the spatial overlap between two sets of segmentations of the same anatomy. Materials and Methods The Dice similarity coefficient (DSC) was used as a statistical validation metric to evaluate the performance of both the reproducibility of manual segmentations and the spatial overlap accuracy of automated probabilistic fractional segmentation of MR images, illustrated on two clinical examples. Example 1: 10 consecutive cases of prostate brachytherapy patients underwent both preoperative 1.5T and intraoperative 0.5T MR imaging. For each case, 5 repeated manual segmentations of the prostate peripheral zone were performed separately on preoperative and on intraoperative images. Example 2: A semi-automated probabilistic fractional segmentation algorithm was applied to MR imaging of 9 cases with 3 types of brain tumors. DSC values were computed and logit-transformed values were compared in the mean with the analysis of variance (ANOVA). Results Example 1: The mean DSCs of 0.883 (range, 0.876–0.893) with 1.5T preoperative MRI and 0.838 (range, 0.819–0.852) with 0.5T intraoperative MRI (P < .001) were within and at the margin of the range of good reproducibility, respectively. Example 2: Wide ranges of DSC were observed in brain tumor segmentations: Meningiomas (0.519–0.893), astrocytomas (0.487–0.972), and other mixed gliomas (0.490–0.899). Conclusion The DSC value is a simple and useful summary measure of spatial overlap, which can be applied to studies of reproducibility and accuracy in image segmentation. We observed generally satisfactory but variable validation results in two clinical applications. This metric may be adapted for similar validation tasks. PMID:14974593
Fatihah, Fadil; Ng, Boon Koon; Hazwanie, Husin; Norimah, A Karim; Shanita, Safii Nik; Ruzita, Abd Talib; Poh, Bee Koon
2015-01-01
INTRODUCTION This study aimed to develop and validate a food frequency questionnaire (FFQ) to assess habitual diets of multi-ethnic Malaysian children aged 7–12 years. METHODS A total of 236 primary school children participated in the development of the FFQ and 209 subjects participated in the validation study, with a subsample of 30 subjects participating in the reproducibility study. The FFQ, consisting of 94 food items from 12 food groups, was compared with a three-day dietary record (3DR) as the reference method. The reproducibility of the FFQ was assessed through repeat administration (FFQ2), seven days after the first administration (FFQ1). RESULTS The results of the validation study demonstrated good acceptance of the FFQ. Mean intake of macronutrients in FFQ1 and 3DR correlated well, although the FFQ intake data tended to be higher. Cross-classification of nutrient intake between the two methods showed that < 7% of subjects were grossly misclassified. Moderate correlations noted between the two methods ranged from r = 0.310 (p < 0.001) for fat to r = 0.497 (p < 0.001) for energy. The reproducibility of the FFQ, as assessed by Cronbach’s alpha, ranged from 0.61 (protein) to 0.70 (energy, carbohydrates and fat). Spearman’s correlations between FFQ1 and FFQ2 ranged from rho = 0.333 (p = 0.072) for protein to rho = 0.479 (p < 0.01) for fat. CONCLUSION These findings indicate that the FFQ is valid and reliable for measuring the average intake of energy and macronutrients in a population of multi-ethnic children aged 7–12 years in Malaysia. PMID:26702165
Shoji, Takuhei; Kato, Naoko; Ishikawa, Sho; Ibuki, Hisashi; Yamada, Norihiro; Kimura, Itaru; Shinoda, Kei
2017-01-01
Objective To evaluate the reproducibility of in vivo crystalline lens measurements obtained by novel commercially available swept-source (SS) optical coherence tomography (OCT) specifically designed for anterior segment imaging. Methods and analysis One eye from each of 30 healthy subjects was randomly selected using the CASIA2 (Tomey, Nagoya, Japan) in two separate visits within a week. Each eye was imaged twice. After image scanning, the anterior and posterior lens curvatures and lens thickness were calculated automatically by the CASIA2 built-in program at 0 dioptre (D) (static), −1 D, −3 D and −5 D accommodative stress. The intraobserver and intervisit reproducibility coefficient (RC) and intraclass correlation coefficient (ICC) were calculated. Results The intraobserver and intervisit RCs ranged from 0.824 to 1.254 mm and 0.789 to 0.911 mm for anterior lens curvature, from 0.276 to 0.299 mm and 0.221 to 0.270 mm for posterior lens curvature and from 0.065 to 0.094 mm and 0.054 to 0.132 mm for lens thickness, respectively. The intraobserver and intervisit ICCs ranged from 0.831 to 0.865 and 0.828 to 0.914 for anterior lens curvature, from 0.832 to 0.898 and 0.840 to 0.933 for posterior lens curvature and from 0.980 to 0.992 and 0.942 to 0.995 for lens thickness. High ICC values were observed for each measurement regardless of accommodative stress. RCs in younger subjects tended to be larger than those in older subjects. Conclusions This novel anterior segment SS-OCT instrument produced reliable in vivo crystalline lens measurement with good repeatability and reproducibility regardless of accommodation stress. PMID:29354706
Arenas, Leveriza F; Ebarvia, Benilda S; Sevilla, Fortunato B
2010-08-01
A piezoelectric quartz crystal (PQC) sensor based on a molecularly imprinted polymer (MIP) has been developed for enantioselective and quantitative analysis of d-(+)-methamphetamine (d(+)-MA). The sensor was produced by bulk polymerization and the resulting MIP was then coated on the gold electrode of an AT-cut quartz crystal. Conditions such as volume of polymer coating, curing time, type of PQC, baseline solvent, pH, and buffer type were found to affect the sensor response and were therefore optimized. The PQC-MIP gave a stable response to different concentrations of d(+)-MA standard solutions (response time = 10 to 100 s) with good repeatability (RSD = 0.03 to 3.09%; n = 3), good reproducibility (RSD = 3.55%; n = 5), and good reversibility (RSD = 0.36%; n = 3). The linear range of the sensor covered five orders of magnitude of analyte concentration, ranging from 10(-5) to 10(-1) microg mL(-1), and the limit of detection was calculated as 11.9 pg d(+)-MA mL(-1) . The sensor had a highly enantioselective response to d(+)-MA compared with its response to l(-)-MA, racemic MA, and phentermine. The developed sensor was validated by applying it to human urine samples from drug-free individuals spiked with standard d(+)-MA and from a confirmed MA user. Use of the standard addition method (SAM) and samples spiked with d(+)-MA at levels ranging from 1 x 10(-3) to 1 x 10(-2) microg mL(-1) showed recovery was good (95.3 to 110.9%).
ERIC Educational Resources Information Center
Lutz, Charlene Howells; Briles, Patricia
1983-01-01
Four student minicenters, concerning friendship, good grooming, good housekeeping, and fitness, are described. Reproducible materials to be used in the centers are included as well as instructions and suggestions. (CJ)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, Kaifang; Reinhardt, Joseph M.; Christensen, Gary E.
2013-12-15
Purpose: Four-dimensional computed tomography (4DCT) can be used to make measurements of pulmonary function longitudinally. The sensitivity of such measurements to identify change depends on measurement uncertainty. Previously, intrasubject reproducibility of Jacobian-based measures of lung tissue expansion was studied in two repeat prior-RT 4DCT human acquisitions. Difference in respiratory effort such as breathing amplitude and frequency may affect longitudinal function assessment. In this study, the authors present normalization schemes that correct ventilation images for variations in respiratory effort and assess the reproducibility improvement after effort correction.Methods: Repeat 4DCT image data acquired within a short time interval from 24 patients priormore » to radiation therapy (RT) were used for this analysis. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. In addition to computing the ventilation maps from end expiration to end inspiration, the authors investigated the effort normalization strategies using other intermediated inspiration phases upon the principles of equivalent tidal volume (ETV) and equivalent lung volume (ELV). Scatter plots and mean square error of the repeat ventilation maps and the Jacobian ratio map were generated for four conditions: no effort correction, global normalization, ETV, and ELV. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2 mm distance-to-agreement and 5% ventilation difference.Results: The pattern of regional pulmonary ventilation changes as lung volume changes. All effort correction strategies improved reproducibility when changes in respiratory effort were greater than 150 cc (p < 0.005 with regard to the gamma pass rate). Improvement of reproducibility was correlated with respiratory effort difference (R = 0.744 for ELV in the cohort with tidal volume difference greater than 100 cc). In general for all subjects, global normalization, ETV and ELV significantly improved reproducibility compared to no effort correction (p = 0.009, 0.002, 0.005 respectively). When tidal volume difference was small (less than 100 cc), none of the three effort correction strategies improved reproducibility significantly (p = 0.52, 0.46, 0.46 respectively). For the cohort (N = 13) with tidal volume difference greater than 100 cc, the average gamma pass rate improves from 57.3% before correction to 66.3% after global normalization, and 76.3% after ELV. ELV was found to be significantly better than global normalization (p = 0.04 for all subjects, and p = 0.003 for the cohort with tidal volume difference greater than 100 cc).Conclusions: All effort correction strategies improve the reproducibility of the authors' pulmonary ventilation measures, and the improvement of reproducibility is highly correlated with the changes in respiratory effort. ELV gives better results as effort difference increase, followed by ETV, then global. However, based on the spatial and temporal heterogeneity in the lung expansion rate, a single scaling factor (e.g., global normalization) appears to be less accurate to correct the ventilation map when changes in respiratory effort are large.« less
Gika, Helen G; Theodoridis, Georgios A; Earll, Mark; Wilson, Ian D
2012-09-01
An approach to the determination of day-to-day analytical robustness of LC-MS-based methods for global metabolic profiling using a pooled QC sample is presented for the evaluation of metabonomic/metabolomic data. A set of 60 urine samples were repeatedly analyzed on five different days and the day-to-day reproducibility of the data obtained was determined. Multivariate statistical analysis was performed with the aim of evaluating variability and selected peaks were assessed and validated in terms of retention time stability, mass accuracy and intensity. The methodology enables the repeatability/reproducibility of extended analytical runs in large-scale studies to be determined, allowing the elimination of analytical (as opposed to biological) variability, in order to discover true patterns and correlations within the data. The day-to-day variability of the data revealed by this process suggested that, for this particular system, 3 days continuous operation was possible without the need for maintenance and cleaning. Variation was generally based on signal intensity changes over the 7-day period of the study, and was mainly a result of source contamination.
NASA Astrophysics Data System (ADS)
Basieva, Irina; Khrennikov, Andrei
2015-10-01
In this paper we study the problem of a possibility to use quantum observables to describe a possible combination of the order effect with sequential reproducibility for quantum measurements. By the order effect we mean a dependence of probability distributions (of measurement results) on the order of measurements. We consider two types of the sequential reproducibility: adjacent reproducibility (A-A) (the standard perfect repeatability) and separated reproducibility(A-B-A). The first one is reproducibility with probability 1 of a result of measurement of some observable A measured twice, one A measurement after the other. The second one, A-B-A, is reproducibility with probability 1 of a result of A measurement when another quantum observable B is measured between two A's. Heuristically, it is clear that the second type of reproducibility is complementary to the order effect. We show that, surprisingly, this may not be the case. The order effect can coexist with a separated reproducibility as well as adjacent reproducibility for both observables A and B. However, the additional constraint in the form of separated reproducibility of the B-A-B type makes this coexistence impossible. The problem under consideration was motivated by attempts to apply the quantum formalism outside of physics, especially, in cognitive psychology and psychophysics. However, it is also important for foundations of quantum physics as a part of the problem about the structure of sequential quantum measurements.
Juárez, M; Polvillo, O; Contò, M; Ficco, A; Ballico, S; Failla, S
2008-05-09
Four different extraction-derivatization methods commonly used for fatty acid analysis in meat (in situ or one-step method, saponification method, classic method and a combination of classic extraction and saponification derivatization) were tested. The in situ method had low recovery and variation. The saponification method showed the best balance between recovery, precision, repeatability and reproducibility. The classic method had high recovery and acceptable variation values, except for the polyunsaturated fatty acids, showing higher variation than the former methods. The combination of extraction and methylation steps had great recovery values, but the precision, repeatability and reproducibility were not acceptable. Therefore the saponification method would be more convenient for polyunsaturated fatty acid analysis, whereas the in situ method would be an alternative for fast analysis. However the classic method would be the method of choice for the determination of the different lipid classes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merolle, L., E-mail: lucia.merolle@elettra.eu; Gianoncelli, A.; Malucelli, E., E-mail: emil.malucelli@unibo.it
2016-01-28
Elemental analysis of biological sample can give information about content and distribution of elements essential for human life or trace elements whose absence is the cause of abnormal biological function or development. However, biological systems contain an ensemble of cells with heterogeneous chemistry and elemental content; therefore, accurate characterization of samples with high cellular heterogeneity may only be achieved by analyzing single cells. Powerful methods in molecular biology are abundant, among them X-Ray microscopy based on synchrotron light source has gaining increasing attention thanks to its extremely sensitivity. However, reproducibility and repeatability of these measurements is one of the majormore » obstacles in achieving a statistical significance in single cells population analysis. In this study, we compared the elemental content of human colon adenocarcinoma cells obtained by three distinct accesses to synchrotron radiation light.« less
Bullard, K M; Hietpas, P B; Ewing, A G
1998-01-01
Polymerase chain reaction (PCR) amplified short tandem repeat (STR) samples from the HUMVWF locus have been analyzed using a unique sample introduction and separation technique. A single capillary is used to transfer samples onto an ultrathin slab gel (57 microm thin). This ultrathin nondenaturing polyacrylamide gel is used to separate the amplified fragments, and laser-induced fluorescence with ethidium bromide is used for detection. The feasibility of performing STR analysis using this system has been investigated by examining the reproducibility for repeated samples. Reproducibility is examined by comparing the migration of the 14 and 17 HUMVWF alleles on three consecutive separations on the ultrathin slab gel. Using one locus, separations match in migration time with the two alleles 42 s apart for each of the three consecutive separations. This technique shows potential to increase sample throughput in STR analysis techniques although separation resolution still needs to be improved.
Reproducibility of CT bone densitometry: operator versus automated ROI definition.
Louis, O; Luypaert, R; Kalender, W; Osteaux, M
1988-05-01
Intrasubject reproducibility with repeated determination of vertebral mineral density from a given set of CT images was investigated. The region of interest (ROI) in 10 patient scans was selected by four independent operators either manually or with an automated procedure separating cortical and spongeous bone, the operators being requested to interact in ROI selection. The mean intrasubject variation was found to be much lower with the automated process (0.3 to 0.6%) than with the conventional method (2.5 to 5.2%). In a second study, 10 patients were examined twice to determine the reproducibility of CT slice selection by the operator. The errors were of the same order of magnitude as in ROI selection.
Speit, Günter; Gminski, Richard; Tauber, Rudolf
2013-08-15
Conflicting results have been published regarding the induction of genotoxic effects by exposure to radiofrequency electromagnetic fields (RF-EMF). Various results indicating a genotoxic potential of RF-EMF were reported by the collaborative EU-funded REFLEX (Risk Evaluation of Potential Environmental Hazards From Low Energy Electromagnetic Field Exposure Using Sensitive in vitro Methods) project. There has been a long-lasting scientific debate about the reliability of the reported results and an attempt to reproduce parts of the results obtained with human fibroblasts failed. Another part of the REFLEX study was performed in Berlin with the human lymphoblastoid cell line HL-60; genotoxic effects of RF-EMF were measured by means of the comet assay and the micronucleus test. The plausibility and reliability of these results were also questioned. In order to contribute to a clarification of the biological significance of the reported findings, a repeat study was performed, involving scientists of the original study. Comet-assay experiments and micronucleus tests were performed under the same experimental conditions that had led to genotoxic effects in the REFLEX study. Here we report that the attempts to reproduce the induction of genotoxic effects by RF-EMF in HL-60 cells failed. No genotoxic effects of RF-EMF were measured in the repeat experiments. We could not find an explanation for the conflicting results. However, the negative repeat experiments suggest that the biological significance of genotoxic effects of RF-EMF reported by the REFLEX study should be re-assessed. Copyright © 2013 Elsevier B.V. All rights reserved.
Lupidi, Marco; Coscas, Florence; Cagini, Carlo; Fiore, Tito; Spaccini, Elisa; Fruttini, Daniela; Coscas, Gabriel
2016-09-01
To describe a new automated quantitative technique for displaying and analyzing macular vascular perfusion using optical coherence tomography angiography (OCT-A) and to determine a normative data set, which might be used as reference in identifying progressive changes due to different retinal vascular diseases. Reliability study. A retrospective review of 47 eyes of 47 consecutive healthy subjects imaged with a spectral-domain OCT-A device was performed in a single institution. Full-spectrum amplitude-decorrelation angiography generated OCT angiograms of the retinal superficial and deep capillary plexuses. A fully automated custom-built software was used to provide quantitative data on the foveal avascular zone (FAZ) features and the total vascular and avascular surfaces. A comparative analysis between central macular thickness (and volume) and FAZ metrics was performed. Repeatability and reproducibility were also assessed in order to establish the feasibility and reliability of the method. The comparative analysis between the superficial capillary plexus and the deep capillary plexus revealed a statistically significant difference (P < .05) in terms of FAZ perimeter, surface, and major axis and a not statistically significant difference (P > .05) when considering total vascular and avascular surfaces. A linear correlation was demonstrated between central macular thickness (and volume) and the FAZ surface. Coefficients of repeatability and reproducibility were less than 0.4, thus demonstrating high intraobserver repeatability and interobserver reproducibility for all the examined data. A quantitative approach on retinal vascular perfusion, which is visible on Spectralis OCT angiography, may offer an objective and reliable method for monitoring disease progression in several retinal vascular diseases. Copyright © 2016 Elsevier Inc. All rights reserved.
Faron, Gilles; Vancutsem, Ellen; Naessens, Anne; Buyl, Ronald; Gucciardo, Leonardo; Foulon, Walter
2017-01-01
Objective . This study aimed to compare the qualitative and quantitative reproducibility of quantitative PCR (qPCR) for Ureaplasma species (Ureaplasma spp.) throughout pregnancy and according to the genital sampling site. Study Design . Between 5 and 14 weeks of gestation (T1), vaginal, fornix, and two cervical samples were taken. Sampling was repeated during the 2nd (T2) and 3rd (T3) trimester in randomly selected T1 positive and negative women. Qualitative and quantitative reproducibility were evaluated using, respectively, Cohen's kappa ( κ ) and interclass correlation coefficients (ICC) and repeated measures ANOVA on the log-transformed mean number of DNA copies for each sampling site. Results . During T1, 51/127 women were positive for U. parvum and 8 for U. urealyticum (4 patients for both). Sampling was repeated for 44/55 women at T2 and/or T3; 43 (97.7%) remained positive at the three timepoints. κ ranged between 0.83 and 0.95 and the ICC for cervical samples was 0.86. Conclusions . Colonization by Ureaplasma spp. seems to be very constant during pregnancy and vaginal samples have the highest detection rate.
A novel method to measure femoral component migration by computed tomography: a cadaver study.
Boettner, Friedrich; Sculco, Peter; Lipman, Joseph; Renner, Lisa; Faschingbauer, Martin
2016-06-01
Radiostereometric analysis (RSA) is the most accurate technique to measure implant migration. However, it requires special equipment, technical expertise and analysis software and has not gained wide acceptance. The current paper analyzes a novel method to measure implant migration utilizing widely available computer tomography (CT). Three uncemented total hip replacements were performed in three human cadavers and six tantalum beads were inserted into the femoral bone similar to RSA. Six different 28 mm heads (-3, 0, 2.5, 5.0, 7.5 and 10 mm) were added to simulate five reproducible translations (maximum total point migration) of the center of the head. Implant migration was measured in a 3-D analysis software (Geomagic Studio 7). Repeat manual reconstructions of the center of the head were performed by two investigators to determine repeatability and accuracy. The accuracy of measurements between the centers of two head sizes was 0.11 mm with a CI 95 % of 0.22 mm. The intra-observer repeatability was 0.13 mm (CI 95 % 0.25 mm). The interrater-reliability was 0.943. CT based measurement of head displacement in a cadaver model were highly accurate and reproducible.
Sancheti, J. S.; Shaikh, M. F.; Khatwani, P. F.; Kulkarni, Savita R.; Sathaye, Sadhana
2013-01-01
A new robust, simple and economic high performance thin layer chromatographic method was developed for simultaneous estimation of L-glutamic acid and γ-amino butyric acid in brain homogenate. The high performance thin layer chromatographic separation of these amino acid was achieved using n-butanol:glacial acetic acid:water (22:3:5 v/v/v) as mobile phase and ninhydrin as a derivatising agent. Quantitation of the method was achieved by densitometric method at 550 nm over the concentration range of 10-100 ng/spot. This method showed good separation of amino acids in the brain homogenate with Rf value of L-glutamic acid and γ-amino butyric acid as 21.67±0.58 and 33.67±0.58, respectively. The limit of detection and limit of quantification for L-glutamic acid was found to be 10 and 20 ng and for γ-amino butyric acid it was 4 and 10 ng, respectively. The method was also validated in terms of accuracy, precision and repeatability. The developed method was found to be precise and accurate with good reproducibility and shows promising applicability for studying pathological status of disease and therapeutic significance of drug treatment. PMID:24591747
Sancheti, J S; Shaikh, M F; Khatwani, P F; Kulkarni, Savita R; Sathaye, Sadhana
2013-11-01
A new robust, simple and economic high performance thin layer chromatographic method was developed for simultaneous estimation of L-glutamic acid and γ-amino butyric acid in brain homogenate. The high performance thin layer chromatographic separation of these amino acid was achieved using n-butanol:glacial acetic acid:water (22:3:5 v/v/v) as mobile phase and ninhydrin as a derivatising agent. Quantitation of the method was achieved by densitometric method at 550 nm over the concentration range of 10-100 ng/spot. This method showed good separation of amino acids in the brain homogenate with Rf value of L-glutamic acid and γ-amino butyric acid as 21.67±0.58 and 33.67±0.58, respectively. The limit of detection and limit of quantification for L-glutamic acid was found to be 10 and 20 ng and for γ-amino butyric acid it was 4 and 10 ng, respectively. The method was also validated in terms of accuracy, precision and repeatability. The developed method was found to be precise and accurate with good reproducibility and shows promising applicability for studying pathological status of disease and therapeutic significance of drug treatment.
Sung, Jun Hyun; Lee, Young Ja; Park, Hyun Jin
2008-08-01
A new method was developed for the determination of epichlorohydrin (ECH) in food contact surface of epoxy-coated cans. The oxolane derivative, which produced by reaction of epoxy moiety in ECH with cyclopentanone in the presence of borontrifluoride-diethyletherate, was analyzed by gas chromatography (GC)/mass spectrometry (MS). 1,2-Epoxyhexane was used as internal standard (IS), which produced an oxolane derivative under the same reaction mechanism as ECH. The developed method was validated with 1 ng ml(-1) of limit of detection (LOD, surface area related 20 ng dm(-2)), >0.999 of linearity. Good precision, which was tested both in terms of intra-day repeatability and inter-day reproducibility, and 97.3-102.7% of good recoveries were obtained on three spiked levels of 5.2, 40.3 and 149.1 ng ml(-1). The excellent validation data suggests that this method is more simple, quick and effective than the official method in European Committee for Standardization (CEN) to determine the residual amount of ECH in food contact materials for food law compliance test. The residual amount of ECH for 13 epoxy-coated can samples was analyzed, and none of the samples was found to be detectable levels of ECH in epoxy-coated cans.
Wang, Licheng; Hou, Xiudan; Li, Jubai; Liu, Shujuan; Guo, Yong
2015-07-01
A novel graphene oxide decorated with silver nanoparticles coating on a stainless-steel fiber for solid-phase microextraction was prepared. Scanning electron microscopy and X-ray photoelectron spectroscopy were used to characterize the coating surface and showed that silver nanoparticles were dispersed on the wrinkled graphene oxide surface. Coupled to gas chromatography with flame ionization detection, the extraction abilities of the fiber for polycyclic aromatic hydrocarbons were examined in the headspace solid-phase microextraction mode. The extraction parameters including adsorption time, adsorption temperature, salt concentration, desorption time and desorption temperature were investigated. Under the optimized condition, wide linearity with low limits of detection from 2 to 10 ng/L was obtained. The relative standard deviations for single-fiber repeatability and fiber-to-fiber reproducibility were less than 10.6 and 17.5%, respectively. The enrichment factors were from 1712.5 to 4503.7, showing the fiber has good extraction abilities. Moreover, the fiber exhibited a good stability and could be reused for more than 120 times. The established method was also applied for determination of polycyclic aromatic hydrocarbons in two real water samples and the recoveries of analytes ranged from 84.4-116.3% with relative standard deviations less than 16.2%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kremer, Kristin; Arnold, Catherine; Cataldi, Angel; Gutiérrez, M. Cristina; Haas, Walter H.; Panaiotov, Stefan; Skuce, Robin A.; Supply, Philip; van der Zanden, Adri G. M.; van Soolingen, Dick
2005-01-01
In recent years various novel DNA typing methods have been developed which are faster and easier to perform than the current internationally standardized IS6110 restriction fragment length polymorphism typing method. However, there has been no overview of the utility of these novel typing methods, and it is largely unknown how they compare to previously published methods. In this study, the discriminative power and reproducibility of nine recently described PCR-based typing methods for Mycobacterium tuberculosis were investigated using the strain collection of the interlaboratory study of Kremer et al. (J. Clin. Microbiol. 37:2607-2618, 1999). This strain collection contains 90 M. tuberculosis complex and 10 non-M. tuberculosis complex mycobacterial strains, as well as 31 duplicated DNA samples to assess reproducibility. The highest reproducibility was found with variable numbers of tandem repeat typing using mycobacterial interspersed repetitive units (MIRU VNTR) and fast ligation-mediated PCR (FLiP), followed by second-generation spoligotyping, ligation-mediated PCR (LM-PCR), VNTR typing using five repeat loci identified at the Queens University of Belfast (QUB VNTR), and the Amadio speciation PCR. Poor reproducibility was associated with fluorescent amplified fragment length polymorphism typing, which was performed in three different laboratories. The methods were ordered from highest discrimination to lowest by the Hunter-Gaston discriminative index as follows: QUB VNTR typing, MIRU VNTR typing, FLiP, LM-PCR, and spoligotyping. We conclude that both VNTR typing methods and FLiP typing are rapid, highly reliable, and discriminative epidemiological typing methods for M. tuberculosis and that VNTR typing is the epidemiological typing method of choice for the near future. PMID:16272496
Reproducibility of the Internal Load and Performance-Based Responses to Simulated Amateur Boxing.
Thomson, Edward D; Lamb, Kevin L
2017-12-01
Thomson, ED and Lamb, KL. Reproducibility of the internal load and performance-based responses to simulated amateur boxing. J Strength Cond Res 31(12): 3396-3402, 2017-The aim of this study was to examine the reproducibility of the internal load and performance-based responses to repeated bouts of a three-round amateur boxing simulation protocol (boxing conditioning and fitness test [BOXFIT]). Twenty-eight amateur boxers completed 2 familiarization trials before performing 2 complete trials of the BOXFIT, separated by 4-7 days. To characterize the internal load, mean (HRmean) and peak (HRpeak) heart rate, breath-by-breath oxygen uptake (V[Combining Dot Above]O2), aerobic energy expenditure, excess carbon dioxide production (CO2excess), and ratings of perceived exertion were recorded throughout each round, and blood lactate determined post-BOXFIT. Additionally, an indication of the performance-based demands of the BOXFIT was provided by a measure of acceleration of the punches thrown in each round. Analyses revealed there were no significant differences (p > 0.05) between repeated trials in any round for all dependent measures. The typical error (coefficient variation %) for all but 1 marker of internal load (CO2excess) was 1.2-16.5% and reflected a consistency that was sufficient for the detection of moderate changes in variables owing to an intervention. The reproducibility of the punch accelerations was high (coefficient of variance % range = 2.1-2.7%). In general, these findings suggest that the internal load and performance-based efforts recorded during the BOXFIT are reproducible and, thereby, offer practitioners a method by which meaningful changes impacting on performance could be identified.
von Arx, Thomas; Janner, Simone F M; Hänni, Stefan; Bornstein, Michael M
2016-02-01
Conventional 2-dimensional radiography uses defined criteria for outcome assessment of apical surgery. However, these radiographic healing criteria are not applicable for 3-dimensional radiography. The present study evaluated the repeatability and reproducibility of new cone-beam computed tomographic (CBCT)-based healing criteria for the judgment of periapical healing 1 year after apical surgery. CBCT scans taken 1 year after apical surgery (61 roots of 54 teeth in 54 patients, mean age = 54.4 years) were evaluated by 3 blinded and calibrated observers using 4 different indices. Reformatted buccolingual CBCT sections through the longitudinal axis of the treated roots were analyzed. Radiographic healing was assessed at the resection plane (R index), within the apical area (A index), of the cortical plate (C index), and regarding a combined apical-cortical area (B index). All readings were performed twice to calculate the intraobserver agreement (repeatability). Second-time readings were used for analyzing the interobserver agreement (reproducibility). Various statistical tests (Cohen, kappa, Fisher, and Spearman) were performed to measure the intra- and interobserver concurrence, the variability of score ratios, and the correlation of indices. For all indices, the rates of identical first- and second-time scores were always higher than 80% (intraobserver Cohen κ values ranging from 0.793 to 0.963). The B index (94.0%) showed the highest intraobserver agreement. Regarding interobserver agreement, the highest rate was found for the B index (72.1%). The Fleiss' κ values for R and B indices exhibited substantial agreement (0.626 and 0.717, respectively), whereas the values for A and C indices showed moderate agreement (0.561 and 0.573, respectively). The Spearman correlation coefficients for R, A, C, and B indices all exhibited a moderate to very strong correlation with the highest correlation found between C and B indices (rs = 0.8069). All indices showed an excellent intraobserver agreement (repeatability). With regard to interobserver agreement (reproducibility), the B index (healing of apical and cortical defects combined) and the R index (healing on the resection plane) showed substantial congruence and thus are to be recommended in future studies when using buccolingual CBCT sections for radiographic outcome assessment of apical surgery. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Removal of the 2-mercaptobenotiazole from model wastewater by ozonation.
Derco, Jan; Kassai, Angelika; Melicher, Michal; Dudas, Jozef
2014-01-01
The feasibility of ozonation process for 2-mercaptobenzothiazole (2-MBT) removal follows from results of ozonation of the model wastewater. Total removal of 2-MBT was observed after 20 minutes of ozonation. Very good reproducibility of repeated ozonation trials including sampling and analysis was observed. However, the majority of dissolved organic carbon (DOC) and chemical oxygen demand (COD) remained in the reaction mixture. Benzothiazole (BT) and 2-hydroxybenzothiazole (OBT) intermediates were identified during degradation of 2-MBT with ozone. In addition to the above benzothiazole derivatives, the creation of some other organic compounds follows from results of mass balance. The best fits of experimental data were obtained using the first kinetic model for 2-MBT and zero-order kinetic model for COD and DOC. The reaction time of 60 minutes can be considered as effective with regard to controlled oxidation in order to increase a portion of partially oxidized substances. Higher biodegradability and lower toxicity of ozonation products on respiration activity of activated sludge microorganisms was observed at higher ozonation time.
Removal of the 2-Mercaptobenotiazole from Model Wastewater by Ozonation
Kassai, Angelika
2014-01-01
The feasibility of ozonation process for 2-mercaptobenzothiazole (2-MBT) removal follows from results of ozonation of the model wastewater. Total removal of 2-MBT was observed after 20 minutes of ozonation. Very good reproducibility of repeated ozonation trials including sampling and analysis was observed. However, the majority of dissolved organic carbon (DOC) and chemical oxygen demand (COD) remained in the reaction mixture. Benzothiazole (BT) and 2-hydroxybenzothiazole (OBT) intermediates were identified during degradation of 2-MBT with ozone. In addition to the above benzothiazole derivatives, the creation of some other organic compounds follows from results of mass balance. The best fits of experimental data were obtained using the first kinetic model for 2-MBT and zero-order kinetic model for COD and DOC. The reaction time of 60 minutes can be considered as effective with regard to controlled oxidation in order to increase a portion of partially oxidized substances. Higher biodegradability and lower toxicity of ozonation products on respiration activity of activated sludge microorganisms was observed at higher ozonation time. PMID:24578619
NASA Astrophysics Data System (ADS)
Sakai, Takamasa; Kohno, Motohiro; Hirae, Sadao; Nakatani, Ikuyoshi; Kusuda, Tatsufumi
1993-09-01
In this paper, we discussed a novel approach to semiconductor surface inspection, which is analysis using the C--V curve measured in a noncontact method by the metal-air-semiconductor (MAIS) technique. A new gap sensing method using the so-called Goos-Haenchen effect was developed to achieve the noncontact C--V measurement. The MAIS technique exhibited comparable sensitivity and repeatability to those of conventional C--V measurement, and hence, good reproducibility and resolution for quantifying the electrically active impurity on the order of 1× 109/cm2, which is better than most spectrometric techniques, such as secondary ion mass spectroscopy (SIMS), electron spectroscopy for chemical analysis (ESCA) and Auger electron spectrocopy (AES) which are time-consuming and destructive. This measurement without preparation of any electrical contact metal electrode suggested, for the first time, the possibility of measuring an intrinsic characteristic of the semiconductor surface, using the examples of a concrete examination.
Harrison, Samantha L; Horton, Elizabeth J; Smith, Robert; Sandland, Carolyn J; Steiner, Michael C; Morgan, Mike D L; Singh, Sally J
2013-01-01
To test the accuracy of a multi-sensor activity monitor (SWM) in detecting slow walking speeds in patients with chronic obstructive pulmonary disease (COPD). Concerns have been expressed regarding the use of pedometers in patient populations. Although activity monitors are more sophisticated devices, their accuracy at detecting slow walking speeds common in patients with COPD has yet to be proven. A prospective observational study design was employed. An incremental shuttle walk test (ISWT) was completed by 57 patients with COPD wearing an SWM. The ISWT was repeated by 20 patients wearing the same SWM. Differences were identified between metabolic equivalents (METS) and between step-count across five levels of the ISWT (p < 0.001). Good within monitor reproducibility between two ISWT was identified for total energy expenditure and step-count (p < 0.001). The SWM is able to detect slow (standardized) speeds of walking and is an acceptable method for measuring physical activity in individuals disabled by COPD. Copyright © 2013 Elsevier Inc. All rights reserved.
Qi, Ping; Lin, Zhihao; Li, Jiaxu; Wang, ChengLong; Meng, WeiWei; Hong, Hong; Zhang, Xuewu
2014-12-01
In this work, a simple, rapid and sensitive analytical method for the determination of rhodamine B in chili-containing foodstuffs is described. The dye is extracted from samples with methanol and analysed without further cleanup procedure by high-performance liquid chromatography (HPLC) coupled to fluorescence detection (FLD). The influence of matrix fluorescent compounds (capsaicin and dihydrocapsaicin) on the analysis was overcome by the optimisation of mobile-phase composition. The limit of determination (LOD) and limit of quantification (LOQ) were 3.7 and 10 μg/kg, respectively. Validation data show a good repeatability and within-lab reproducibility with relative standard deviations <10%. The overall recoveries are in the range of 98-103% in chili powder and in the range of 87-100% in chili oil depending on the concentration of rhodamine B in foodstuffs. This method is suitable for the routine analysis of rhodamine B due to its sensitivity, simplicity, reasonable time and cost. Copyright © 2014 Elsevier Ltd. All rights reserved.
Lefebvre, P; Agadir, A; Cornic, M; Gourmel, B; Hue, B; Dreux, C; Degos, L; Chomienne, C
1995-04-07
All-trans retinoic acid (all-trans RA), the active metabolite of vitamin A, has been demonstrated to be an efficient alternative to chemotherapy in the treatment of acute promyelocytic leukemia (APL), the AML3 subtype of the FAB cytological classification. Complete remission is obtained by inducing terminal granulocytic differentiation of the leukemic cells. To study all-trans RA pharmacokinetics in patients with APL, a rapid, precise and selective high-performance liquid chromatographic (HPLC) assay was developed. This method is easy and shows good repeatability (C.V. = 8.41-12.44%), reproducibility (C.V. = 9.19-14.73%), accuracy (C.V. = 3.5-11%) and sensitivity with a detection limit of 5 pmol/ml. The analysis is performed using normal-phase HPLC in an isocratic mode with UV detection after solid-phase extraction on octadecyl (C18) columns. The mobile phase is hexane-dichloromethane-dioxane (78:18:4, v/v) containing 1% acetic acid.
EL-Houssini, Ola M.; Zawilla, Nagwan H.; Mohammad, Mohammad A.
2013-01-01
Specific stability indicating reverse-phase liquid chromatography (RP-LC) assay method (SIAM) was developed for the determination of cinnarizine (Cinn)/piracetam (Pira) and cinnarizine (Cinn)/heptaminol acefyllinate (Hept) in the presence of the reported degradation products of Cinn. A C18 column and gradient mobile phase was applied for good resolution of all peaks. The detection was achieved at 210 nm and 254 nm for Cinn/Pira and Cinn/Hept, respectively. The responses were linear over concentration ranges of 20–200, 20–1000 and 25–1000 μgmL−1 for Cinn, Pira, and Hept respectively. The proposed method was validated for linearity, accuracy, repeatability, intermediate precision, and robustness via statistical analysis of the data. The method was shown to be precise, accurate, reproducible, sensitive, and selective for the analysis of Cinn/Pira and Cinn/Hept in laboratory prepared mixtures and in pharmaceutical formulations. PMID:24137049
Radiotherapy dosimetry using a commercial OSL system.
Viamonte, A; da Rosa, L A R; Buckley, L A; Cherpak, A; Cygler, J E
2008-04-01
A commercial optically stimulated luminescence (OSL) system developed for radiation protection dosimetry by Landauer, Inc., the InLight microStar reader, was tested for dosimetry procedures in radiotherapy. The system uses carbon-doped aluminum oxide, Al2O3:C, as a radiation detector material. Using this OSL system, a percent depth dose curve for 60Co gamma radiation was measured in solid water. Field size and SSD dependences of the detector response were also evaluated. The dose response relationship was investigated between 25 and 400 cGy. The decay of the response with time following irradiation and the energy dependence of the Al2O3:C OSL detectors were also measured. The results obtained using OSL dosimeters show good agreement with ionization chamber and diode measurements carried out under the same conditions. Reproducibility studies show that the response of the OSL system to repeated exposures is 2.5% (1sd), indicating a real possibility of applying the Landauer OSL commercial system for radiotherapy dosimetric procedures.
NASA Astrophysics Data System (ADS)
Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il
2008-11-01
Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (-90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range.
Zhou, Shaofeng; Han, Xiaojuan; Fan, Honglei; Liu, Yaqing
2016-06-22
Au nanoparticles decorated mesoporous MnFe₂O₄ nanocrystal clusters (MnFe₂O₄/Au hybrid nanospheres) were used for the electrochemical sensing of As(III) by square wave anodic stripping voltammetry (SWASV). Modified on a cheap glass carbon electrode, these MnFe₂O₄/Au hybrid nanospheres show favorable sensitivity (0.315 μA/ppb) and limit of detection (LOD) (3.37 ppb) toward As(III) under the optimized conditions in 0.1 M NaAc-HAc (pH 5.0) by depositing for 150 s at the deposition potential of -0.9 V. No obvious interference from Cd(II) and Hg(II) was recognized during the detection of As(III). Additionally, the developed electrode displayed good reproducibility, stability, and repeatability, and offered potential practical applicability for electrochemical detection of As(III) in real water samples. The present work provides a potential method for the design of new and cheap sensors in the application of electrochemical determination toward trace As(III) and other toxic metal ions.
Longo, Caterina; Pontassuglia, Carmen; Corriero, Giuseppe; Gaino, Elda
2012-01-01
The calcareous sponge Paraleucilla magna, originally observed along the Brazilian coast (Atlantic Ocean), is the only allochthonous invasive species of Porifera reported in the Mediterranean Sea. A 1-year investigation of the population dynamics and life-cycle of this exotic species in the Mar Piccolo di Taranto (southern Italy, central Mediterranean Sea) has provided a good opportunity to test how environmental variations can influence its life-cycle and to ascertain what strategy can be adopted to successfully colonize a new environment. In the Mar Piccolo di Taranto, P. magna exhibits marked temporal changes in biomass. The studied specimens reproduce almost all year round, showing a seasonal pattern that peaks during warm months. This prolonged sexual activity allows P. magna to continuously produce young specimens, with repeated recruitment events taking place throughout the year, thus offsetting the seasonal mortality of adult specimens. This r-strategy enables the non-indigenous sponge to achieve a high degree of maintenance over relatively long periods (ten years at least). PMID:22905128
Total elemental composition analysis of soil samples using the PIXE technique
NASA Astrophysics Data System (ADS)
Bolormaa, Oyuntsetseg; Baasansuren, Jamsranjav; Kawasaki, Katsunori; Watanabe, Makiko; Hattroi, Toshiyuki
2007-09-01
The determination of major and trace element contents in soils was developed by acid digestion method combined with particle-induced X-ray emission spectrometry (PIXE). The digestion of soils was achieved by using nitric acid (HNO3), hydrochloric acid HCl and hydrogen peroxide (H2O2) with repeated additions. A 20 μL aliquot from the digested samples was evaporated on the Nuclepore Track-Etch Membrane and irradiated by the 2.5 MeV proton beam from the single-end type Van de Graaff accelerator. The accuracy of this methodology was estimated based on series of measurements done for a reference material of soil CRM 023-050. The proposed experimental procedure was shown to have good reproducibility of the experimental results. The corresponding limits of detection (LODs) for Na, Mg, Al, P, S, Cl, K, Cr, Mn, Fe, Ni, Cu, Zn, As, Sr, Mo and Cd were estimated. Other soil characteristics such as total carbon (TC) and nitrogen (TN) content, pH and electrical conductivity (EC) were also measured.
de Beer, Jessica L.; Kremer, Kristin; Ködmön, Csaba; Supply, Philip
2012-01-01
Although variable-number tandem-repeat (VNTR) typing has gained recognition as the new standard for the DNA fingerprinting of Mycobacterium tuberculosis complex (MTBC) isolates, external quality control programs have not yet been developed. Therefore, we organized the first multicenter proficiency study on 24-locus VNTR typing. Sets of 30 DNAs of MTBC strains, including 10 duplicate DNA samples, were distributed among 37 participating laboratories in 30 different countries worldwide. Twenty-four laboratories used an in-house-adapted method with fragment sizing by gel electrophoresis or an automated DNA analyzer, nine laboratories used a commercially available kit, and four laboratories used other methods. The intra- and interlaboratory reproducibilities of VNTR typing varied from 0% to 100%, with averages of 72% and 60%, respectively. Twenty of the 37 laboratories failed to amplify particular VNTR loci; if these missing results were ignored, the number of laboratories with 100% interlaboratory reproducibility increased from 1 to 5. The average interlaboratory reproducibility of VNTR typing using a commercial kit was better (88%) than that of in-house-adapted methods using a DNA analyzer (70%) or gel electrophoresis (50%). Eleven laboratories using in-house-adapted manual typing or automated typing scored inter- and intralaboratory reproducibilities of 80% or higher, which suggests that these approaches can be used in a reliable way. In conclusion, this first multicenter study has documented the worldwide quality of VNTR typing of MTBC strains and highlights the importance of international quality control to improve genotyping in the future. PMID:22170917
Ripoche, N; Ferchaud-Roucher, V; Krempf, M; Ritz, P
2006-09-01
In doubly labelled water studies, biological sample enrichments are mainly measured using off-line techniques (equilibration followed by dual-inlet introduction) or high-temperature elemental analysis (HT-EA), coupled with an isotope-ratio mass spectrometer (IRMS). Here another continuous-flow method, (CF-EA/IRMS), initially dedicated to water, is tested for plasma and urine analyses. The elemental analyser configuration is adapted for each stable isotope: chromium tube for deuterium reduction and glassy carbon reactor for 18O pyrolysis. Before on-line conversion of water into gas, each matrix is submitted to a short and easy treatment, which is the same for the analysis of the two isotopes. Plasma is passed through centrifugal filters. Urine is cleaned with black carbon and filtered (0.45 microm diameter). Tested between 150 and 300 ppm in these fluids, the D/H ratio response is linear with good repeatability (SD<0.2 ppm) and reproducibility (SD<0.5 ppm). For 18O/16O ratios (from 2000 to 2200 ppm), the same repeatability is obtained with a between-day precision lower than 1.4 ppm. The accuracy on biological samples is validated by comparison to classical dual-inlet methods: 18O analyses give more accurate results. The data show that enriched physiological fluids can be successfully analysed in CF-EA/IRMS. Copyright (c) 2006 John Wiley & Sons, Ltd.
Reproducibility of the kinematics and kinetics of the lower extremity during normal stair-climbing.
Yu, B; Kienbacher, T; Growney, E S; Johnson, M E; An, K N
1997-05-01
The purpose of this study was to examine the intrasubject reproducibility of the kinematic and kinetic measures of the lower extremity during normal stair-climbing. Three-dimensional video and force-plate data were collected for three trials per subject during each of three conditions: ascending, descending, and level walking. Three-dimensional angles and moments of the ankle, knee, and hip joints were calculated. The coefficient of multiple correlation was used to determine the intrasubject reproducibility of joint angles and resultant moments. Analysis of variance with repeated measures was conducted to compare the magnitudes of the coefficients between different steps, different joints, and different joint functions. The results showed that (a) generally, the kinematic and kinetic measures of normal subjects climbing stairs were reproducible; (b) the kinetic measures during the transition steps from level walking to ascending and from descending to level walking were significantly less reproducible than those during the other steps; (c) the data from the sagittal plane were more reproducible than those from the other two planes; and (d) the kinetic measures were more reproducible than the kinematic measures, especially for abduction-adduction and internal-external rotation.
Vanmolkot, Floris H M; de Hoon, Jan N J M
2005-01-01
Aims To assess the reproducibility of the forearm blood flow (FBF) response to intra-arterial infusion of calcitonin-gene related peptide (CGRP), measured by venous occlusion plethysmography. In addition, to compare different ways of expressing the FBF response and perform sample size calculations. Methods On two separate visits, CGRP (10 ng min−1 dl−1 forearm) was infused for 45 min into the brachial artery of six healthy subjects. Reproducibility was assessed by calculating mean difference, repeatability coefficient, within-subject coefficient of variation (WCV) and intraclass correlation coefficient. Results CGRP increased FBF from 2.8 ± 0.4 and 3.2 ± 0.7 (at baseline) to 15.4 ± 1.4 and 15.2 ± 1.5 ml min−1 dl−1 forearm (at 45 min) on visits 1 and 2, respectively (P < 0.0001 for both visits). Mean difference in FBF at 45 min between both visits was 0.3 ml min−1 dl−1 forearm (repeatability coefficient: 4.1 ml min−1 dl−1 forearm). This FBF response appeared to be more reproducible when expressed as absolute FBF in the infused arm (WCV 11%) compared with absolute FBF-ratio between both arms (WCV 37%), percentage change from baseline in FBF in the infused arm (WCV 29%) and percentage change from baseline in FBF-ratio (WCV 40%). When expressed as absolute FBF, a sample size of five (95% confidence interval: 2–12) subjects gives 90% power at a type I error probability of 0.05 to detect a 25% shift in FBF response. Conclusions Intra-arterial infusion of CGRP results in a forearm vasodilator response which is reproducible between days. This response is most reproducible when expressed as absolute FBF. The presented methodology provides a suitable pharmacodynamic model to assess the in vivo activity of CGRP-receptor antagonists in a small number of subjects. PMID:15801933
A Novel Actinic Keratosis Field Assessment Scale for Grading Actinic Keratosis Disease Severity.
Dréno, Brigitte; Cerio, Rino; Dirschka, Thomas; Nart, Ignasi Figueras; Lear, John T; Peris, Ketty; de Casas, Andrés Ruiz; Kaleci, Shaniko; Pellacani, Giovanni
2017-10-02
Actinic keratosis (AK) lesions are surrounded by field cancerization (areas of subclinical, non-visible sun damage). Existing AK grading tools rely on AK counts, which are not reproducible. An Actinic Keratosis Field Assessment Scale (AK-FAS) for grading the severity of AK/field was developed. Standardized photographs of patients representing the full range of AK severity were collected. Six investigators independently rated each photograph according to 3 criteria: AK area (total skin area affected by AK lesions), hyperkeratosis and sun damage. Inter-rater reproducibility was good for all 3 criteria. Validation of the AK-FAS showed good reproducibility for AK area and hyperkeratosis, even for dermatologists untrained on use of the scale. In conclusion, the AK-FAS is objective, easy to use and implement, and reproducible. It incorporates assessment of the entire field affected by AK instead of relying on lesion counts. Use of the AK-FAS may standardize AK diagnosis, making it relevant to routine clinical practice.
ERIC Educational Resources Information Center
Connell, Raewyn
2016-01-01
This paper considers how we can arrive at a concept of the good university. It begins with ideas expressed by Australian Vice-Chancellors and in the "league tables" for universities, which essentially reproduce existing privilege. It then considers definitions of the good university via wish lists, classic texts, horror lists, structural…
A novel method for repeatedly generating speckle patterns used in digital image correlation
NASA Astrophysics Data System (ADS)
Zhang, Juan; Sweedy, Ahmed; Gitzhofer, François; Baroud, Gamal
2018-01-01
Speckle patterns play a key role in Digital Image Correlation (DIC) measurement, and generating an optimal speckle pattern has been the goal for decades now. The usual method of generating a speckle pattern is by manually spraying the paint on the specimen. However, this makes it difficult to reproduce the optimal pattern for maintaining identical testing conditions and achieving consistent DIC results. This study proposed and evaluated a novel method using an atomization system to repeatedly generate speckle patterns. To verify the repeatability of the speckle patterns generated by this system, simulation and experimental studies were systematically performed. The results from both studies showed that the speckle patterns and, accordingly, the DIC measurements become highly accurate and repeatable using the proposed atomization system.
Structural Basis of Egg Coat-Sperm Recognition at Fertilization.
Raj, Isha; Sadat Al Hosseini, Hamed; Dioguardi, Elisa; Nishimura, Kaoru; Han, Ling; Villa, Alessandra; de Sanctis, Daniele; Jovine, Luca
2017-06-15
Recognition between sperm and the egg surface marks the beginning of life in all sexually reproducing organisms. This fundamental biological event depends on the species-specific interaction between rapidly evolving counterpart molecules on the gametes. We report biochemical, crystallographic, and mutational studies of domain repeats 1-3 of invertebrate egg coat protein VERL and their interaction with cognate sperm protein lysin. VERL repeats fold like the functionally essential N-terminal repeat of mammalian sperm receptor ZP2, whose structure is also described here. Whereas sequence-divergent repeat 1 does not bind lysin, repeat 3 binds it non-species specifically via a high-affinity, largely hydrophobic interface. Due to its intermediate binding affinity, repeat 2 selectively interacts with lysin from the same species. Exposure of a highly positively charged surface of VERL-bound lysin suggests that complex formation both disrupts the organization of egg coat filaments and triggers their electrostatic repulsion, thereby opening a hole for sperm penetration and fusion. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Lozano, Ana; Pérez-Parada, Andrés; Heinzen, Horacio; Fernández-Alba, Amadeo R
2012-01-01
In spite of high plant growth regulator application rates, little has been reported in the literature on determination of their residues in fruits and vegetables. This would be useful in monitoring good manufacturing practices and overall safety through the enforcement of maximum residue levels (MRLs). The present work describes method validation for the determination of 1-naphthylacetic acid (NAA) and 2(1-naphthyl)acetamide (NAAm) in tomato and zucchini using the mini-Luke, ethyl acetate (EtOAc) and acetate-buffered quick, easy, cheap, effective, rugged, and safe (QuEChERS) methods. Samples were spiked at two different levels: 50 and 100 pg/kg for NAA and 20 and 100 pg/kg for NAAm. These compounds were analyzed within the same chromatographic run with LC coupled to triple quadrupole MS (LC/(QqQ)MS/MS) in positive and negative electrospray ionization [ESI(+) and ESI(-)] modes for NAAm and NAA, respectively. For analyte confirmation, LC/ESI(-)QTOF-MS was also investigated given that NAA has only one multiple reaction monitoring transition (185.1-*140.9 m/z). These three common methods were used to determine linearity, recoveries, precision (RSD), matrix effects, repeatability, and reproducibility (n = 5) for the selected matrixes. In terms of the Directorate-General for Health and Consumers (DG-SANCO) guidelines, only insignificant differences were found for the multiresidue methods tested, regardless of the commodity. Matrix-matched calibration was used, and LODs were below 10.1 pg/kg for NAA and 6.0 pg/kg for NAAm, which were lower than the MRLs established in current European Union legislation for these compounds. Obtained recoveries for NAA ranged from 87 to 107% with RSD values below 10% for mini-Luke, 83 to 107% with RSD <11% for EtOAc, and 76 to 85% with RSD <7% for QuEChERS. NAAm recoveries ranged from 74 to 102% with RSD 5 15% for mini-Luke, 76 to 97% with RSD <4% for EtOAc, and 76 to 93% with RSD < 5% for QuEChERS. The linearity of the response over two orders of magnitude was demonstrated (r2 > 0.996) for all methods used. Good repeatability and reproducibility in terms of RSD were obtained (11.3-17.8%) for these analytical methods. The results were acceptable within the studied ranges for both analytes in all methods. As these multiresidue methods are used at the present time in many laboratories, this survey indicates that these analytes should be included in their monitoring scope.
Kakite, Suguru; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Facciuto, Marcelo; Donnerhack, Claudia; Taouli, Bachir
2015-01-01
To evaluate short-term test-retest and interobserver reproducibility of IVIM (intravoxel incoherent motion) diffusion parameters and ADC (apparent diffusion coefficient) of hepatocellular carcinoma (HCC) and liver parenchyma at 3.0T. In this prospective Institutional Review Board (IRB)-approved study, 11 patients were scanned twice using a free-breathing single-shot echo-planar-imaging, diffusion-weighted imaging (DWI) sequence using 4 b values (b = 0, 50, 500, 1000 s/mm(2)) and IVIM DWI using 16 b values (0-800 s/mm(2)) at 3.0T. IVIM parameters (D: true diffusion coefficient, D*: pseudodiffusion coefficient, PF: perfusion fraction) and ADC (using 4 b and 16 b) were calculated. Short-term test-retest and interobserver reproducibility of IVIM parameters and ADC were assessed by measuring correlation coefficient, coefficient of variation (CV), and Bland-Altman limits of agreements (BA-LA). Fifteen HCCs were assessed in 10 patients. Reproducibility of IVIM metrics in HCC was poor for D* and PF (mean CV 60.6% and 37.3%, BA-LA: -161.6% to 135.3% and -66.2% to 101.0%, for D* and PF, respectively), good for D and ADC (CV 19.7% and <16%, BA-LA -57.4% to 36.3% and -38.2 to 34.1%, for D and ADC, respectively). Interobserver reproducibility was on the same order of test-retest reproducibility except for PF in HCC. Reproducibility of diffusion parameters was better in liver parenchyma compared to HCC. Poor reproducibility of D*/PF and good reproducibility for D/ADC were observed in HCC and liver parenchyma. These findings may have implications for trials using DWI in HCC. © 2014 Wiley Periodicals, Inc.
The Role of Pattern Goodness in the Reproduction of Backward Masked Patterns
ERIC Educational Resources Information Center
Bell, Herbert H.; Handel, Stephen
1976-01-01
The purpose of the present work was to investigate the relation between pattern goodness and accuracy of reproduction in backward masking. It may be hypothesized that good patterns, being easier to encode as wholes, will be reproduced more easily than poorer patterns. Four experiments were performed. (Author)
Container-Based Clinical Solutions for Portable and Reproducible Image Analysis.
Matelsky, Jordan; Kiar, Gregory; Johnson, Erik; Rivera, Corban; Toma, Michael; Gray-Roncal, William
2018-05-08
Medical imaging analysis depends on the reproducibility of complex computation. Linux containers enable the abstraction, installation, and configuration of environments so that software can be both distributed in self-contained images and used repeatably by tool consumers. While several initiatives in neuroimaging have adopted approaches for creating and sharing more reliable scientific methods and findings, Linux containers are not yet mainstream in clinical settings. We explore related technologies and their efficacy in this setting, highlight important shortcomings, demonstrate a simple use-case, and endorse the use of Linux containers for medical image analysis.
Pemp, Berthold; Kardon, Randy H; Kircher, Karl; Pernicka, Elisabeth; Schmidt-Erfurth, Ursula; Reitner, Andreas
2013-07-01
Automated detection of subtle changes in peripapillary retinal nerve fibre layer thickness (RNFLT) over time using optical coherence tomography (OCT) is limited by inherent image quality before layer segmentation, stabilization of the scan on the peripapillary retina and its precise placement on repeated scans. The present study evaluates image quality and reproducibility of spectral domain (SD)-OCT comparing different rates of automatic real-time tracking (ART). Peripapillary RNFLT was measured in 40 healthy eyes on six different days using SD-OCT with an eye-tracking system. Image brightness of OCT with unaveraged single frame B-scans was compared to images using ART of 16 B-scans and 100 averaged frames. Short-term and day-to-day reproducibility was evaluated by calculation of intraindividual coefficients of variation (CV) and intraclass correlation coefficients (ICC) for single measurements as well as for seven repeated measurements per study day. Image brightness, short-term reproducibility, and day-to-day reproducibility were significantly improved using ART of 100 frames compared to one and 16 frames. Short-term CV was reduced from 0.94 ± 0.31 % and 0.91 ± 0.54 % in scans of one and 16 frames to 0.56 ± 0.42 % in scans of 100 averaged frames (P ≤ 0.003 each). Day-to-day CV was reduced from 0.98 ± 0.86 % and 0.78 ± 0.56 % to 0.53 ± 0.43 % (P ≤ 0.022 each). The range of ICC was 0.94 to 0.99. Sample size calculations for detecting changes of RNFLT over time in the range of 2 to 5 μm were performed based on intraindividual variability. Image quality and reproducibility of mean peripapillary RNFLT measurements using SD-OCT is improved by averaging OCT images with eye-tracking compared to unaveraged single frame images. Further improvement is achieved by increasing the amount of frames per measurement, and by averaging values of repeated measurements per session. These strategies may allow a more accurate evaluation of RNFLT reduction in clinical trials observing optic nerve degeneration.
Krusiec-Swidergoł, B; Jonderko, K
2008-06-01
We checked on reproducibility of parameters of a multichannel electrogastrogram in adults after intake of typical, applied in electrogastrography, test meals. Recordings of multichannel electrogastrograms were accomplished in four blocks comprising 18 subjects (nine healthy volunteers and nine patients with functional GI disorders) each. Every subject had two examinations taken 1-2 days apart, and a third one was accomplished at least 2 weeks before or after the two other sessions. The registration involved a 30-min fasted and a 2-h postprandial period after one of the meal stimuli tested within a given block: 400 mL water, 400 g yoghurt (378 kcal), a scrambled eggs sandwich (370 kcal), a pancake (355 kcal). From among the parameters reflecting the propagation of the gastric slow waves, the average percentage of slow wave coupling (APSWC) exhibited a good (coefficient of variation for paired examinations CV(p) < or = 10%) to moderate (10 < CV(p) < or = 30%) reproducibility. On the other hand, the reproducibility of the maximum dominant frequency difference and the spatial dominant power difference was found to be unsatisfactory. The reproducibility of the multichannel electrogastrographic parameters did not differ between healthy volunteers and patients with functional GI disorders. Gender or the kind of a test meal did not affect the reproducibility of the electrogastrographic parameters either. The medium-term reproducibility was not any worse than the short-term one. From among the parameters of a multichannel electrogastrogram intended to quantify the propagation of slow waves, only the APSWC offers a reproducibility potentially good enough for clinical applications.
Repeatability study of replicate crash tests: A signal analysis approach.
Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason
2017-10-03
To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test protocols.
NASA Astrophysics Data System (ADS)
Biallas, Martin; Trajkovic, Ivo; Hagmann, Cornelia; Scholkmann, Felix; Jenny, Carmen; Holper, Lisa; Beck, Andreas; Wolf, Martin
2012-08-01
In this study 14 healthy term newborns (postnatal mean age 2.1 days) underwent photic stimulation during sleep on two different days. Near-infrared spectroscopy (NIRS) and electroencephalography (EEG) was acquired simultaneously. The aims of the study were: to determine (i) the sensitivity and (ii) the repeatability of NIRS to detect the hemodynamic response, (iii) the sensitivity and (iv) the repeatability of EEG to detect a visual evoked potential (VEP), (v) to analyze optical data for the optical neuronal signal, and (vi) to test whether inadequate stimulation could be reason for absent hemodynamic responses. The results of the study were as follows. (i) Sensitivity of NIRS was 61.5% to detect hemodynamic responses; (ii) their reproducibility was 41.7%. A VEP was detected (iii) in 96.3% of all subjects with (iv) a reproducibility of 92.3%. (v) In two measurements data met the criteria for an optical neuronal signal. The noise level was 9.6.10-5% change in optical density. (vi) Insufficient stimulation was excluded as reason for absent hemodynamic responses. We conclude that NIRS is an promising tool to study cognitive activation and development of the brain. For clinical application, however, the sensitivity and reproducibility on an individual level needs to be improved.
Reliability of vascular geometry factors derived from clinical MRA
NASA Astrophysics Data System (ADS)
Bijari, Payam B.; Antiga, Luca; Steinman, David A.
2009-02-01
Recent work from our group has demonstrated that the amount of disturbed flow at the carotid bifurcation, believed to be a local risk factor for carotid atherosclerosis, can be predicted from luminal geometric factors. The next step along the way to a large-scale retrospective or prospective imaging study of such local risk factors for atherosclerosis is to investigate whether these geometric features are reproducible and accurate from routine 3D contrast-enhanced magnetic resonance angiography (CEMRA) using a fast and practical method of extraction. Motivated by this fact, we examined the reproducibility of multiple geometric features that are believed important in atherosclerosis risk assessment. We reconstructed three-dimensional carotid bifurcations from 15 clinical study participants who had previously undergone baseline and repeat CEMRA acquisitions. Certain geometric factors were extracted and compared between the baseline and the repeat scan. As the spatial resolution of the CEMRA data was noticeably coarse and anisotropic, we also investigated whether this might affect the measurement of the same geometric risk factors by simulating the CEMRA acquisition for 15 normal carotid bifurcations previously acquired at high resolution. Our results show that the extracted geometric factors are reproducible and faithful, with intra-subject uncertainties well below inter-subject variabilities. More importantly, these geometric risk factors can be extracted consistently and quickly for potential use as disturbed flow predictors.
Doblas, Sabrina; Almeida, Gilberto S; Blé, François-Xavier; Garteiser, Philippe; Hoff, Benjamin A; McIntyre, Dominick J O; Wachsmuth, Lydia; Chenevert, Thomas L; Faber, Cornelius; Griffiths, John R; Jacobs, Andreas H; Morris, David M; O'Connor, James P B; Robinson, Simon P; Van Beers, Bernard E; Waterton, John C
2015-12-01
To evaluate between-site agreement of apparent diffusion coefficient (ADC) measurements in preclinical magnetic resonance imaging (MRI) systems. A miniaturized thermally stable ice-water phantom was devised. ADC (mean and interquartile range) was measured over several days, on 4.7T, 7T, and 9.4T Bruker, Agilent, and Magnex small-animal MRI systems using a common protocol across seven sites. Day-to-day repeatability was expressed as percent variation of mean ADC between acquisitions. Cross-site reproducibility was expressed as 1.96 × standard deviation of percent deviation of ADC values. ADC measurements were equivalent across all seven sites with a cross-site ADC reproducibility of 6.3%. Mean day-to-day repeatability of ADC measurements was 2.3%, and no site was identified as presenting different measurements than others (analysis of variance [ANOVA] P = 0.02, post-hoc test n.s.). Between-slice ADC variability was negligible and similar between sites (P = 0.15). Mean within-region-of-interest ADC variability was 5.5%, with one site presenting a significantly greater variation than the others (P = 0.0013). Absolute ADC values in preclinical studies are comparable between sites and equipment, provided standardized protocols are employed. © 2015 Wiley Periodicals, Inc.
Improved rice method for determining theoretical maximum density of asphalt paving mixtures
DOT National Transportation Integrated Search
1992-05-01
Rice method (ASTM D2041 ) is used for determining the theoretical maximum specific gravity of asphalt paving mixtures which is one of the main test parameters used for mix design and construction quality control. The repeatability and reproducibility...
Li, Yi; Zhang, Min; Yang, Yaoxia; Wang, Xuemei; Du, Xinzhen
2014-09-05
A novel TiO2-nanosheets coated fiber for solid-phase microextraction (SPME) was fabricated by anodization of Ti wire substrates in ethylene glycol with concentrated NH4F. The in situ fabricated TiO2-nanosheets were densely embedded into Ti substrates with about 1μm long, 300nm wide and 80nm thick. The as-fabricated TiO2-nanosheets coating was employed to extract polycyclic aromatic hydrocarbons, phthalates and ultraviolet (UV) filters in combination with high performance liquid chromatography-UV detection (HPLC-UV). It was found that the TiO2-nanosheets coating exhibited high extraction capability and good selectivity for some UV filters frequently used in cosmetic sunscreen formulations. The main parameters affecting extraction performance were investigated and optimized. Under the optimized conditions, the calibration graphs were linear in the range of 0.1-400μgL(-1). The limits of detection of the proposed method were between 0.026μgL(-1) and 0.089μgL(-1) (S/N=3). The single fiber repeatability varied from 4.50% to 8.76% and the fiber-to-fiber reproducibility ranged from 7.75% to 9.64% for the extraction of spiked water with 50μgL(-1) UV filters (n=5). The SPME-HPLC-UV method was successfully established for the selective preconcentration and sensitive detection of target UV filters from real environmental water samples. Recovery of UV filters spiked at 10μgL(-1) and 25μgL(-1) ranged from 88.8% to 107% and the relative standard deviations were less than 9.8%. Furthermore the in situ growth of the TiO2-nanosheets coating was performed in a highly reproducible manner and the TiO2-nanosheets coated fiber has high mechanical strength, good stability and long service life. Copyright © 2014 Elsevier B.V. All rights reserved.
Validated spectrophotometric methods for determination of some oral hypoglycemic drugs.
Farouk, M; Abdel-Satar, O; Abdel-Aziz, O; Shaaban, M
2011-02-01
Four accurate, precise, rapid, reproducible, and simple spectrophotometric methods were validated for determination of repaglinide (RPG), pioglitazone hydrochloride (PGL) and rosiglitazone maleate (RGL). The first two methods were based on the formation of a charge-transfer purple-colored complex of chloranilic acid with RPG and RGL with a molar absorptivity 1.23 × 103 and 8.67 × 102 l•mol-1•cm-1 and a Sandell's sensitivity of 0.367 and 0.412 μg•cm-2, respectively, and an ion-pair yellow-colored complex of bromophenol blue with RPG, PGL and RGL with molar absorptivity 8.86 × 103, 6.95 × 103, and 7.06 × 103 l•mol-1•cm-1, respectively, and a Sandell's sensitivity of 0.051 μg•cm-2 for all ion-pair complexes. The influence of different parameters on color formation was studied to determine optimum conditions for the visible spectrophotometric methods. The other spectrophotometric methods were adopted for demtermination of the studied drugs in the presence of their acid-, alkaline- and oxidative-degradates by computing derivative and pH-induced difference spectrophotometry, as stability-indicating techniques. All the proposed methods were validated according to the International Conference on Harmonization guidelines and successfully applied for determination of the studied drugs in pure form and in pharmaceutical preparations with good extraction recovery ranges between 98.7-101.4%, 98.2-101.3%, and 99.9-101.4% for RPG, PGL, and RGL, respectively. Results of relative standard deviations did not exceed 1.6%, indicating that the proposed methods having good repeatability and reproducibility. All the obtained results were statistically compared to the official method used for RPG analysis and the manufacturers methods used for PGL and RGL analysis, respectively, where no significant differences were found.
A novel and fast method for proton range verification using a step wedge and 2D scintillator.
Shen, Jiajian; Allred, Bryce C; Robertson, Daniel G; Liu, Wei; Sio, Terence T; Remmes, Nicholas B; Keole, Sameer R; Bues, Martin
2017-09-01
To implement and evaluate a novel and fast method for proton range verification by using a planar scintillator and step wedge. A homogenous proton pencil beam plan with 35 energies was designed and delivered to a 2D flat scintillator with a step wedge. The measurement was repeated 15 times (3 different days, 5 times per day). The scintillator image was smoothed, the Bragg peak and distal fall off regions were fitted by an analytical equation, and the proton range was calculated using simple trigonometry. The accuracy of this method was verified by comparing the measured ranges to those obtained using an ionization chamber and a scanning water tank, the gold standard. The reproducibility was evaluated by comparing the ranges over 15 repeated measurements. The sensitivity was evaluated by delivering to same beam to the system with a film inserted under the wedge. The range accuracy of all 35 proton energies measured over 3 days was within 0.2 mm. The reproducibility in 15 repeated measurements for all 35 proton ranges was ±0.045 mm. The sensitivity to range variation is 0.1 mm for the worst case. This efficient procedure permits measurement of 35 proton ranges in less than 3 min. The automated data processing produces results immediately. The setup of this system took less than 5 min. The time saving by this new method is about two orders of magnitude when compared with the time for water tank range measurements. A novel method using a scintillator with a step wedge to measure the proton range was implemented and evaluated. This novel method is fast and sensitive, and the proton range measured by this method was accurate and highly reproducible. © 2017 American Association of Physicists in Medicine.
Comparison of radiographic and anatomic femoral varus angle measurements in normal dogs.
Swiderski, Jennifer K; Radecki, Steven V; Park, Richard D; Palmer, Ross H
2008-01-01
To determine if the clinically practiced method of radiographic femoral varus angle (R-FVA) measurement is repeatable, reproducible, and accurate. Radiographic and anatomic study. ANIMALS/SAMPLE POPULATION: Normal Walker hound cadavers (n=5) and femora (n=10). Cadavers were held in dorsally-recumbent and torso-elevated positions as 3 craniocaudal radiographs were made of each femur, by each of 2 different technicians. Femora were then harvested for direct measurement of anatomic femoral varus angle (A-FVA). R-FVA was measured on each radiograph by each of 3 examiners on 3 separate occasions. Intra-observer (repeatability) and inter-observer (reproducibility) variance in R-FVA measurement and the strength of relationship between R-FVA and A-FVA (accuracy) were determined. Mean (+/-SD) A-FVA was 5.2+/-2.1 degrees (range, 2.4-8.2 degrees). Mean (+/-SD) R-FVA was 5.8+/-1.0 degrees (range, 2.7-9.6 degrees). Intra-observer variance (range: 11-16%) and inter-observer variance (16%) were acceptable. The strength of relationship between measured R-FVA and A-FVA (maximum adjusted R(2)<0) was unacceptably low regardless of observer, patient position, or radiographic technician. R-FVA measurement was repeatable and reproducible, but not statistically accurate in predicting A-FVA in these 5 normal Walker hounds. The detected inaccuracy may be real or the result of a selection bias for normal dogs obscuring the true relationship. R-FVA may not be an accurate method of femoral varus measurement in dogs with A-FVA<10 degrees. Using Slocum's criteria for distal femoral osteotomy (R-FVA>10 degrees), the procedure would not have been erroneously performed in any of the normal dogs of this study.
López-Miguel, Alberto; Calabuig-Goena, María; Marqués-Fernández, Victoria; Fernández, Itziar; Alió, Jorge L; Maldonado, Miguel J
2016-11-04
To assess the reliability of corneal epithelial thickness (CET), nonepithelial central corneal thickness (NECCT), and central corneal thickness (CCT) measurements using Cirrus high-definition optical coherence tomography (HD-OCT) in patients who did and did not undergo cataract surgery. Forty patients who underwent uneventful phacoemulsification and 40 healthy participants were recruited to evaluate the intraobserver repeatability and interobserver reproducibility of CET, NECCT, and CCT measurements using Cirrus HD-OCT. To analyze repeatability, one examiner obtained 5 consecutive scans in each participant; for interobserver reproducibility, another examiner randomly obtained another scan. Within-subject standard deviation, coefficient of variation (CV), limits of agreement, and intraclass correlation coefficient (ICC) data were obtained. For intraobserver repeatability, the intrasession CV (CVw) and ICC values of the CET in the operated and nonoperated groups were 3.7% and 0.80 and 3.8% and 0.73, respectively; for NECCT, 0.7% and 0.98 and 0.8% and 0.97; and for CCT, 0.6% and 0.99 and 0.7% and 0.98. For interobserver reproducibility, the CVw and ICC values for the CET in the operated and nonoperated groups were 2.6% and 0.82 and 2.3% and 0.62, respectively; for NECCT, 0.7% and 0.98 and 0.5% and 0.98; and for CCT, 0.5% and 0.99 and 0.4% and 0.99. The corneal sublayer thickness can be measured reliably using Cirrus HD-OCT in patients who underwent cataract surgery and elderly participants; however, the CET consistency is poorer than the NECCT. Corneal epithelial thickness modifications exceeding 4% reflect true thickness changes instead of random error variations using HD-OCT.
Gu, Dongfeng; Zhao, Qi; Chen, Jing; Chen, Ji-Chun; Huang, Jianfeng; Bazzano, Lydia A; Lu, Fanghong; Mu, Jianjun; Li, Jianxin; Cao, Jie; Mills, Katherine; Chen, Chung-Shiuan; Rice, Treva; Hamm, L Lee; He, Jiang
2013-09-01
Blood pressure responses to dietary sodium and potassium interventions vary among individuals. We studied the long-term reproducibility of blood pressure responses to dietary sodium and potassium intake. We repeated the dietary sodium and potassium interventions among 487 Chinese adults 4.5 years after the original dietary intervention. The identical dietary intervention protocol, which included a 7-day low-sodium feeding (51.3 mmol/d), a 7-day high-sodium feeding (307.8 mmol/d), and a 7-day high-sodium feeding with oral potassium supplementation (60.0 mmol/d), was applied in both the initial and repeated studies. Three blood pressure measurements were obtained during each of the 3 days of baseline observation and on days 5, 6, and 7 of each intervention period. The results from the 24-hour urinary excretion of sodium and potassium showed excellent compliance with the study diet. Blood pressure responses to dietary intervention in the original and repeated studies were highly correlated. For example, the correlation coefficients (95% confidence interval) for systolic blood pressure levels were 0.77 (0.73-0.80) at baseline, 0.79 (0.75-0.82) during low sodium, 0.80 (0.77-0.83) during high sodium, and 0.82 (0.79-0.85) during high sodium and potassium supplementation interventions (all P<0.0001). The correlation coefficients for systolic blood pressure changes were 0.37 (0.29-0.44) from baseline to low sodium, 0.37 (0.29-0.44) from low to high sodium, and 0.28 (0.20-0.36) from high sodium to high sodium plus potassium supplementation (all P<0.0001). These data indicate that blood pressure responses to dietary sodium and potassium interventions have long-term reproducibility and stable characteristics in the general population.
Assessing Cognitive Performance in Badminton Players: A Reproducibility and Validity Study
van de Water, Tanja; Faber, Irene; Elferink-Gemser, Marije
2017-01-01
Abstract Fast reaction and good inhibitory control are associated with elite sports performance. To evaluate the reproducibility and validity of a newly developed Badminton Reaction Inhibition Test (BRIT), fifteen elite (25 ± 4 years) and nine non-elite (24 ± 4 years) Dutch male badminton players participated in the study. The BRIT measured four components: domain-general reaction time, badminton-specific reaction time, domain-general inhibitory control and badminton-specific inhibitory control. Five participants were retested within three weeks on the badminton-specific components. Reproducibility was acceptable for badminton-specific reaction time (ICC = 0.626, CV = 6%) and for badminton-specific inhibitory control (ICC = 0.317, CV = 13%). Good construct validity was shown for badminton-specific reaction time discriminating between elite and non-elite players (F = 6.650, p < 0.05). Elite players did not outscore non-elite players on domain-general reaction time nor on both components of inhibitory control (p > 0.05). Concurrent validity for domain-general reaction time was good, as it was associated with a national ranking for elite (p = 0.70, p < 0.01) and non-elite (p = 0.70, p < 0.05) players. No relationship was found between the national ranking and badminton-specific reaction time, nor both components of inhibitory control (p > 0.05). In conclusion, reproducibility and validity of inhibitory control assessment was not confirmed, however, the BRIT appears a reproducible and valid measure of reaction time in badminton players. Reaction time measured with the BRIT may provide input for training programs aiming to improve badminton players’ performance. PMID:28210347
Assessing Cognitive Performance in Badminton Players: A Reproducibility and Validity Study.
van de Water, Tanja; Huijgen, Barbara; Faber, Irene; Elferink-Gemser, Marije
2017-01-01
Fast reaction and good inhibitory control are associated with elite sports performance. To evaluate the reproducibility and validity of a newly developed Badminton Reaction Inhibition Test (BRIT), fifteen elite (25 ± 4 years) and nine non-elite (24 ± 4 years) Dutch male badminton players participated in the study. The BRIT measured four components: domain-general reaction time, badminton-specific reaction time, domain-general inhibitory control and badminton-specific inhibitory control. Five participants were retested within three weeks on the badminton-specific components. Reproducibility was acceptable for badminton-specific reaction time (ICC = 0.626, CV = 6%) and for badminton-specific inhibitory control (ICC = 0.317, CV = 13%). Good construct validity was shown for badminton-specific reaction time discriminating between elite and non-elite players (F = 6.650, p < 0.05). Elite players did not outscore non-elite players on domain-general reaction time nor on both components of inhibitory control (p > 0.05). Concurrent validity for domain-general reaction time was good, as it was associated with a national ranking for elite (p = 0.70, p < 0.01) and non-elite (p = 0.70, p < 0.05) players. No relationship was found between the national ranking and badminton-specific reaction time, nor both components of inhibitory control (p > 0.05). In conclusion, reproducibility and validity of inhibitory control assessment was not confirmed, however, the BRIT appears a reproducible and valid measure of reaction time in badminton players. Reaction time measured with the BRIT may provide input for training programs aiming to improve badminton players' performance.
Clint, S A; Eastwood, D M; Chasseaud, M; Calder, P R; Marsh, D R
2010-02-01
Although there is much in the literature regarding pin site infections, there is no accepted, validated method for documenting their state. We present a system for reliably labelling pin sites on any ring fixator construct and an easy-to-remember grading system to document the state of each pin site. Each site is graded in terms of erythema, pain and discharge to give a 3-point scale, named "Good", "Bad" and "Ugly" for ease of recall. This system was tested for intra- and inter-observer reproducibility. 15 patients undergoing elective limb reconstruction were recruited. A total of 218 pin sites were independently scored by 2 examiners. 82 were then re-examined later by the same examiners. 514 pin sites were felt to be "Good", 80 "Bad" and 6 "Ugly". The reproducibility of the system was found to be excellent. We feel our system gives a quick, reliable and reproducible method to monitor individual pin sites and their response to treatment. Crown Copyright 2009. Published by Elsevier Ltd. All rights reserved.
Du, Xue-Fei; Xiao, Meng; Liang, Hong-Yan; Sun, Zhe; Jiang, Yue-Hong; Chen, Guo-Yu; Meng, Xiao-Yu; Zou, Gui-Ling; Zhang, Li; Liu, Ya-Li; Zhang, Hui; Sun, Hong-Li; Jiang, Xiao-Feng; Xu, Ying-Chun
2014-01-01
Methicillin-resistant Staphylococcus aureus (MRSA) has become an important nosocomial pathogen, causing considerable morbidity and mortality. During the last 20 years, a variety of genotyping methods have been introduced for screening the prevalence of MRSA. In this study, we developed and evaluated an improved approach capillary gel electrophoresis based multilocus variable-number tandem-repeat fingerprinting (CGE/MLVF) for rapid MRSA typing. A total of 42 well-characterized strains and 116 non-repetitive clinical MRSA isolates collected from six hospitals in northeast China between 2009 and 2010 were tested. The results obtained by CGE/MLVF against clinical isolates were compared with traditional MLVF, spa typing, Multilocus sequence typing/staphylococcal cassette chromosome mec (MLST/SCCmec) and pulse field gel electrophoresis (PFGE). The discriminatory power estimated by Simpson’s index of diversity was 0.855 (28 types), 0.855 (28 patterns), 0.623 (11 types), 0.517 (8 types) and 0.854 (28 patterns) for CGE/MLVF, traditional MLVF, spa typing, MLST/SCCmec and PFGE, respectively. All methods tested showed a satisfied concordance in clonal complex level calculated by adjusted Rand’s coefficient. CGE/MLVF showed better reproducibility and accuracy than traditional MLVF and PFGE methods. In addition, the CGE/MLVF has potential to produce portable results. In conclusion, CGE/MLVF is a rapid and easy to use MRSA typing method with lower cost, good reproducibility and high discriminatory power for monitoring the outbreak and clonal spread of MRSA isolates. PMID:24406728
Stein, R.S.; King, G.C.P.; Rundle, J.B.
1988-01-01
A strong test of our understanding of the earthquake cycle is the ability to reproduce extant faultbounded geological structures, such as basins and ranges, which are built by repeated cycles of deformation. Three examples are considered for which the structure and fault geometry are well known: the White Wolf reverse fault in California, site of the 1952 Kern County M=7.3 earthquake, the Lost River normal fault in Idaho, site of the 1983 Borah Peak M=7.0 earthquake, and the Cricket Mountain normal fault in Utah, site of Quaternary slip events. Basin stratigraphy and seismic reflection records are used to profile the structure, and coseismic deformation measured by leveling surveys is used to estimate the fault geometry. To reproduce these structures, we add the deformation associated with the earthquake cycle (the coseismic slip and postseismic relaxation) to the flexure caused by the observed sediment load, treating the crust as a thin elastic plate overlying a fluid substrate. -from Authors
Measurement uncertainty of the EU methods for microbiological examination of red meat.
Corry, Janet E L; Hedges, Alan J; Jarvis, Basil
2007-09-01
Three parallel trials were made of EU methods proposed for the microbiological examination of red meat using two analysts in each of seven laboratories within the UK. The methods involved determination of aerobic colony count (ACC) and Enterobacteriaceae colony count (ECC) using simulated methods and a freeze-dried standardised culture preparation. Trial A was based on a simulated swab test, Trial B a simulated meat excision test and Trial C was a reference test on reconstituted inoculum. Statistical analysis (ANOVA) was carried out before and after rejection of outlying data. Expanded uncertainty values (relative standard deviation x2) for repeatability and reproducibility, based on the log10 cfu/ml, on the ACC ranged from +/-2.1% to +/-2.7% and from +/-5.5% to +/-10.5%, respectively, depending upon the test procedure. Similarly for the ECC, expanded uncertainty estimates for repeatability and reproducibility ranged from +/-4.6% to +/-16.9% and from +/-21.6% to +/-23.5%, respectively. The results are discussed in relation to the potential application of the methods.
Dayton, Melody; Koskinen, Mikko T; Tom, Bradley K; Mattila, Anna-Maria; Johnston, Eric; Halverson, Joy; Fantin, Dennis; DeNise, Sue; Budowle, Bruce; Smith, David Glenn; Kanthaswamy, Sree
2009-01-01
Aim To develop a reagent kit that enables multiplex polymerase chain reaction (PCR) amplification of 18 short tandem repeats (STR) and the canine sex-determining Zinc Finger marker. Methods Validation studies to determine the robustness and reliability in forensic DNA typing of this multiplex assay included sensitivity testing, reproducibility studies, intra- and inter-locus color balance studies, annealing temperature and cycle number studies, peak height ratio determination, characterization of artifacts such as stutter percentages and dye blobs, mixture analyses, species-specificity, case type samples analyses and population studies. Results The kit robustly amplified domesticated dog samples and consistently generated full 19-locus profiles from as little as 125 pg of dog DNA. In addition, wolf DNA samples could be analyzed with the kit. Conclusion The kit, which produces robust, reliable, and reproducible results, will be made available for the forensic research community after modifications based on this study’s evaluation to comply with the quality standards expected for forensic casework. PMID:19480022
NASA Astrophysics Data System (ADS)
Cabalín, L. M.; González, A.; Ruiz, J.; Laserna, J. J.
2010-08-01
Statistical uncertainty in the quantitative analysis of solid samples in motion by laser-induced breakdown spectroscopy (LIBS) has been assessed. For this purpose, a LIBS demonstrator was designed and constructed in our laboratory. The LIBS system consisted of a laboratory-scale conveyor belt, a compact optical module and a Nd:YAG laser operating at 532 nm. The speed of the conveyor belt was variable and could be adjusted up to a maximum speed of 2 m s - 1 . Statistical uncertainty in the analytical measurements was estimated in terms of precision (reproducibility and repeatability) and accuracy. The results obtained by LIBS on shredded scrap samples under real conditions have demonstrated that the analytical precision and accuracy of LIBS is dependent on the sample geometry, position on the conveyor belt and surface cleanliness. Flat, relatively clean scrap samples exhibited acceptable reproducibility and repeatability; by contrast, samples with an irregular shape or a dirty surface exhibited a poor relative standard deviation.
Measurement System Analyses - Gauge Repeatability and Reproducibility Methods
NASA Astrophysics Data System (ADS)
Cepova, Lenka; Kovacikova, Andrea; Cep, Robert; Klaput, Pavel; Mizera, Ondrej
2018-02-01
The submitted article focuses on a detailed explanation of the average and range method (Automotive Industry Action Group, Measurement System Analysis approach) and of the honest Gauge Repeatability and Reproducibility method (Evaluating the Measurement Process approach). The measured data (thickness of plastic parts) were evaluated by both methods and their results were compared on the basis of numerical evaluation. Both methods were additionally compared and their advantages and disadvantages were discussed. One difference between both methods is the calculation of variation components. The AIAG method calculates the variation components based on standard deviation (then a sum of variation components does not give 100 %) and the honest GRR study calculates the variation components based on variance, where the sum of all variation components (part to part variation, EV & AV) gives the total variation of 100 %. Acceptance of both methods among the professional society, future use, and acceptance by manufacturing industry were also discussed. Nowadays, the AIAG is the leading method in the industry.
HESS Opinions: Repeatable research: what hydrologistscan learn from the Duke cancer research scandal
Fienen, Michael; Bakker, Mark
2016-01-01
In the past decade, difficulties encountered in reproducing the results of a cancer study at Duke University resulted in a scandal and an investigation which concluded that tools used for data management, analysis, and modeling were inappropriate for the documentation of the study, let alone the reproduction of the results. New protocols were developed which require that data analysis and modeling be carried out with scripts that can be used to reproduce the results and are a record of all decisions and interpretations made during an analysis or a modeling effort. In the hydrological sciences, we face similar challenges and need to develop similar standards for transparency and repeatability of results. A promising route is to start making use of open-source languages (such as R and Python) to write scripts and to use collaborative coding environments (such as Git) to share our codes for inspection and use by the hydrological community. An important side-benefit to adopting such protocols is consistency and efficiency among collaborators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sleiman, Mohamad; Chen, Sharon; Gilbert, Haley E.
A laboratory method to simulate natural exposure of roofing materials has been reported in a companion article. Here in the current article, we describe the results of an international, nine-participant interlaboratory study (ILS) conducted in accordance with ASTM Standard E691-09 to establish the precision and reproducibility of this protocol. The accelerated soiling and weathering method was applied four times by each laboratory to replicate coupons of 12 products representing a wide variety of roofing categories (single-ply membrane, factory-applied coating (on metal), bare metal, field-applied coating, asphalt shingle, modified-bitumen cap sheet, clay tile, and concrete tile). Participants reported initial and laboratory-agedmore » values of solar reflectance and thermal emittance. Measured solar reflectances were consistent within and across eight of the nine participating laboratories. Measured thermal emittances reported by six participants exhibited comparable consistency. For solar reflectance, the accelerated aging method is both repeatable and reproducible within an acceptable range of standard deviations: the repeatability standard deviation sr ranged from 0.008 to 0.015 (relative standard deviation of 1.2–2.1%) and the reproducibility standard deviation sR ranged from 0.022 to 0.036 (relative standard deviation of 3.2–5.8%). The ILS confirmed that the accelerated aging method can be reproduced by multiple independent laboratories with acceptable precision. In conclusion, this study supports the adoption of the accelerated aging practice to speed the evaluation and performance rating of new cool roofing materials.« less
An open science peer review oath.
Aleksic, Jelena; Alexa, Adrian; Attwood, Teresa K; Chue Hong, Neil; Dahlö, Martin; Davey, Robert; Dinkel, Holger; Förstner, Konrad U; Grigorov, Ivo; Hériché, Jean-Karim; Lahti, Leo; MacLean, Dan; Markie, Michael L; Molloy, Jenny; Schneider, Maria Victoria; Scott, Camille; Smith-Unna, Richard; Vieira, Bruno Miguel
2014-01-01
One of the foundations of the scientific method is to be able to reproduce experiments and corroborate the results of research that has been done before. However, with the increasing complexities of new technologies and techniques, coupled with the specialisation of experiments, reproducing research findings has become a growing challenge. Clearly, scientific methods must be conveyed succinctly, and with clarity and rigour, in order for research to be reproducible. Here, we propose steps to help increase the transparency of the scientific method and the reproducibility of research results: specifically, we introduce a peer-review oath and accompanying manifesto. These have been designed to offer guidelines to enable reviewers (with the minimum friction or bias) to follow and apply open science principles, and support the ideas of transparency, reproducibility and ultimately greater societal impact. Introducing the oath and manifesto at the stage of peer review will help to check that the research being published includes everything that other researchers would need to successfully repeat the work. Peer review is the lynchpin of the publishing system: encouraging the community to consciously (and conscientiously) uphold these principles should help to improve published papers, increase confidence in the reproducibility of the work and, ultimately, provide strategic benefits to authors and their institutions.
Modest validity and fair reproducibility of dietary patterns derived by cluster analysis.
Funtikova, Anna N; Benítez-Arciniega, Alejandra A; Fitó, Montserrat; Schröder, Helmut
2015-03-01
Cluster analysis is widely used to analyze dietary patterns. We aimed to analyze the validity and reproducibility of the dietary patterns defined by cluster analysis derived from a food frequency questionnaire (FFQ). We hypothesized that the dietary patterns derived by cluster analysis have fair to modest reproducibility and validity. Dietary data were collected from 107 individuals from population-based survey, by an FFQ at baseline (FFQ1) and after 1 year (FFQ2), and by twelve 24-hour dietary recalls (24-HDR). Repeatability and validity were measured by comparing clusters obtained by the FFQ1 and FFQ2 and by the FFQ2 and 24-HDR (reference method), respectively. Cluster analysis identified a "fruits & vegetables" and a "meat" pattern in each dietary data source. Cluster membership was concordant for 66.7% of participants in FFQ1 and FFQ2 (reproducibility), and for 67.0% in FFQ2 and 24-HDR (validity). Spearman correlation analysis showed reasonable reproducibility, especially in the "fruits & vegetables" pattern, and lower validity also especially in the "fruits & vegetables" pattern. κ statistic revealed a fair validity and reproducibility of clusters. Our findings indicate a reasonable reproducibility and fair to modest validity of dietary patterns derived by cluster analysis. Copyright © 2015 Elsevier Inc. All rights reserved.
Reproducibility of techniques using Archimedes' principle in measuring cancellous bone volume.
Zou, L; Bloebaum, R D; Bachus, K N
1997-01-01
Researchers have been interested in developing techniques to accurately and reproducibly measure the volume fraction of cancellous bone. Historically bone researchers have used Archimedes' principle with water to measure the volume fraction of cancellous bone. Preliminary results in our lab suggested that the calibrated water technique did not provide reproducible results. Because of this difficulty, it was decided to compare the conventional water method to a water with surfactant and a helium method using a micropycnometer. The water/surfactant and the helium methods were attempts to improve the fluid penetration into the small voids present in the cancellous bone structure. In order to compare the reproducibility of the new methods with the conventional water method, 16 cancellous bone specimens were obtained from femoral condyles of human and greyhound dog femora. The volume fraction measurements on each specimen were repeated three times with all three techniques. The results showed that the helium displacement method was more than an order of magnitudes more reproducible than the two other water methods (p < 0.05). Statistical analysis also showed that the conventional water method produced the lowest reproducibility (p < 0.05). The data from this study indicate that the helium displacement technique is a very useful, rapid and reproducible tool for quantitatively characterizing anisotropic porous tissue structures such as cancellous bone.
Onyśk, Agnieszka; Boczkowska, Maja
2017-01-01
Simple Sequence Repeat (SSR) markers are one of the most frequently used molecular markers in studies of crop diversity and population structure. This is due to their uniform distribution in the genome, the high polymorphism, reproducibility, and codominant character. Additional advantages are the possibility of automatic analysis and simple interpretation of the results. The M13 tagged PCR reaction significantly reduces the costs of analysis by the automatic genetic analyzers. Here, we also disclose a short protocol of SSR data analysis.
Long-term reproducibility of relative sensitivity factors obtained with CAMECA Wf
NASA Astrophysics Data System (ADS)
Gui, D.; Xing, Z. X.; Huang, Y. H.; Mo, Z. Q.; Hua, Y. N.; Zhao, S. P.; Cha, L. Z.
2008-12-01
As the wafer size continues to increase and the feature size of the integrated circuits (IC) continues to shrink, process control of IC manufacturing becomes ever more important to reduce the cost of failures caused by the drift of processes or equipments. Characterization tools with high precision and reproducibility are required to capture any abnormality of the process. Although Secondary ion mass spectrometry (SIMS) has been widely used in dopant profile control, it was reported that magnetic sector SIMS, compared to quadrupole SIMS, has lower short-term repeatability and long-term reproducibility due to the high extraction field applied between sample and extraction lens. In this paper, we demonstrate that CAMECA Wf can deliver high long-term reproducibility because of its high-level automation and improved design of immersion lens. The relative standard deviation (R.S.D.) of the relative sensitivity factors (RSF) of three typical elements, i.e., boron (B), phosphorous (P) and nitrogen (N), over 3 years are 3.7%, 5.5% and 4.1%, respectively. The high reproducibility results have a practical implication that deviation can be estimated without testing the standards.
[Reproducibility of subjective refraction measurement].
Grein, H-J; Schmidt, O; Ritsche, A
2014-11-01
Reproducibility of subjective refraction measurement is limited by various factors. The main factors affecting reproducibility include the characteristics of the measurement method and of the subject and the examiner. This article presents the results of a study on this topic, focusing on the reproducibility of subjective refraction measurement in healthy eyes. The results of previous studies are not all presented in the same way by the respective authors and cannot be fully standardized without consulting the original scientific data. To the extent that they are comparable, the results of our study largely correspond largely with those of previous investigations: During repeated subjective refraction measurement, 95% of the deviation from the mean value was approximately ±0.2 D to ±0.65 D for the spherical equivalent and cylindrical power. The reproducibility of subjective refraction measurement in healthy eyes is limited, even under ideal conditions. Correct assessment of refraction results is only feasible after identifying individual variability. Several measurements are required. Refraction cannot be measured without a tolerance range. The English full-text version of this article is available at SpringerLink (under supplemental).
Chen, Xiao; Geng, Ling; Li, Hong
2014-04-01
To compare the clinical outcomes and cost-effectiveness of luteal phase down-regulation with gonadotrophin-releasing hormone (GnRH) agonist protocol and GnRH antagonist protocol in patients undergoing repeated in vitro fertilization and intracytoplasmic sperm injection (IVF-ICSI) cycles. A retrospective analysis of clinical outcomes and costs was conducted among 198 patients undergoing repeated IVF-ICSI cycles, including 109 receiving luteal phase down-regulation with GnRH agonist protocol (group A) and 89 receiving GnRH antagonist protocol (group B). The numbers of oocytes retrieved and good embryos, clinical pregnancy rate, abortion rate, the live birth rate, mean total cost, and the cost-effective ratio were compared between the two groups. In patients undergoing repeated IVF-ICSI cycles, the two protocols produced no significant differences in the number of good embryos, clinical pregnancy rate, abortion rate, or twin pregnancy rate. Compared with group B, group A had better clinical outcomes though this difference was not statistically significant. The number of retrieved oocytes was significantly greater and live birth rate significantly higher in group A than in group B (9.13=4.98 vs 7.11=4.74, and 20.2% vs 9.0%, respectively). Compared with group B, group A had higher mean total cost per cycle but lower costs for each oocyte retrieved (2729.11 vs 3038.60 RMB yuan), each good embryo (8867.19 vs 9644.85 RMB yuan), each clinical pregnancy (77598.06 vs 96139.85 RMB yuan). For patients undergoing repeated IVF/ICSI cycle, luteal phase down-regulation with GnRH agonist protocol produces good clinical outcomes with also good cost-effectiveness in spite an unsatisfactory ovarian reserve.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-25
... from subheading 3502.90; or A change to peptones and their derivatives, other protein substances and..., prostagladins, thromboxanes and leukotrienes, natural or reproduced by synthesis, derivatives and structural..., thromboxanes and leukotrienes, natural or reproduced by synthesis or derivatives, and structural analogues...
EOS microdose protocol for the radiological follow-up of adolescent idiopathic scoliosis.
Ilharreborde, Brice; Ferrero, Emmanuelle; Alison, Marianne; Mazda, Keyvan
2016-02-01
Imaging plays a key role in adolescent idiopathic scoliosis (AIS) to determine the prognosis and accordingly define the best therapeutic strategy to follow. Conventional radiographs with ionizing radiation have been associated with 1-2 % increased lifetime risk of developing cancer in children, and physicians, therefore, need a sensitive but harmless way to explore patients at risk, according to the "as low as reasonably achievable" concept. The EOS system (EOS imaging, Paris, France) is available in routine clinical use since 2007, and allows 3D reconstructions of the trunk in standing position with significant radiation reduction. With recent technical advances, further dose reduction can be obtained, but at the cost of image quality that might alter the reliability of 3D reconstructions. The aim of the present study was to analyze the reproducibility of a "microdose" protocol, and evaluate its use in clinical practice. 32 consecutive patients followed for AIS were prospectively included. Biplanar radiographs were obtained with the EOS system according to the new microdose protocol. From the microdose images obtained, three experienced operators performed 3D reconstructions, two times for each subject in a random order (total, 192 reconstructions). The intraoperator repeatability and interoperator reproducibility were evaluated, as recommended by the International Organization for Standardization, for the most clinically relevant 3D radiological parameters. The identification of the required anatomical landmarks for the "fast spine" reconstruction process was possible in all cases. None of the patients required a second acquisition for 3D analysis. Mean time for reconstruction was 5 ± 2 min. The intraoperator repeatability was better than interoperator reproducibility for all parameters, with values ranging between 3° and 8° for frontal and sagittal spinal parameters, and between 1° and 8° for pelvic measurements. The agreement was very good for all clinical measurements. No correlation was found between the BMI and the reliability of the measurements. Because children are notably more sensitive to the carcinogenic effects of ionizing radiation, judicious use of imaging methods and a search for newer technologies remain necessary. Results of the current study show that the new microdose acquisition protocol can be used in clinical practice without altering the quality of the images. Relevant clinical measurements can be made manually, but the landmarks are also visible enough to allow accurate 3D reconstructions (ICC >0.91 for all parameters). The resulting radiation exposure was 5.5 times lower than that received with the prior protocol, corresponding now to a 45-fold reduction compared to conventional radiographs, and can, therefore, almost be considered negligible.
Repeated Prescribed Burning in Aspen
Donald A. Perala
1974-01-01
Infrequent burning weather, low flammability of the aspen-hardwood association, and prolific sprouting and seeding of shrubs and hardwoods made repeated dormant season burning a poor tool to convert good site aspen to conifers. Repeat fall burns for wildlife habitat maintenance is workable if species composition changes are not important.
Thomas, Freddy; Jamin, Eric
2009-09-01
An international collaborative study of isotopic methods applied to control the authenticity of vinegar was organized in order to support the recognition of these procedures as official methods. The determination of the 2H/1H ratio of the methyl site of acetic acid by SNIF-NMR (site-specific natural isotopic fractionation-nuclear magnetic resonance) and the determination of the 13C/12C ratio, by IRMS (isotope ratio mass spectrometry) provide complementary information to characterize the botanical origin of acetic acid and to detect adulterations of vinegar using synthetic acetic acid. Both methods use the same initial steps to recover pure acetic acid from vinegar. In the case of wine vinegar, the determination of the 18O/16O ratio of water by IRMS allows to differentiate wine vinegar from vinegars made from dried grapes. The same set of vinegar samples was used to validate these three determinations. The precision parameters of the method for measuring delta13C (carbon isotopic deviation) were found to be similar to the values previously obtained for similar methods applied to wine ethanol or sugars extracted from fruit juices: the average repeatability (r) was 0.45 per thousand, and the average reproducibility (R) was 0.91 per thousand. As expected from previous in-house study of the uncertainties, the precision parameters of the method for measuring the 2H/1H ratio of the methyl site were found to be slightly higher than the values previously obtained for similar methods applied to wine ethanol or fermentation ethanol in fruit juices: the average repeatability was 1.34 ppm, and the average reproducibility was 1.62 ppm. This precision is still significantly smaller than the differences between various acetic acid sources (delta13C and delta18O) and allows a satisfactory discrimination of vinegar types. The precision parameters of the method for measuring delta18O were found to be similar to the values previously obtained for other methods applied to wine and fruit juices: the average repeatability was 0.15 per thousand, and the average reproducibility was 0.59 per thousand. The above values are proposed as repeatability and reproducibility limits in the current state of the art. On the basis of this satisfactory inter-laboratory precision and on the accuracy demonstrated by a spiking experiment, the authors recommend the adoption of the three isotopic determinations included in this study as official methods for controlling the authenticity of vinegar.
Serinelli, Serenella; Panebianco, Valeria; Martino, Milvia; Battisti, Sofia; Rodacki, Karina; Marinelli, Enrico; Zaccagna, Fulvio; Semelka, Richard C; Tomei, Ernesto
2015-05-01
In forensic practice, there is a growing need for accurate methods of age estimation, especially in the cases of young individuals of unknown age. Age can be estimated through somatic features that are universally considered associated with chronological age. Unfortunately, these features do not always coincide with the real chronological age: for these reasons that age determination is often very difficult. Our aim is to evaluate accuracy of skeletal age estimation using Tomei's MRI method in subjects between 12 and 19 years old for forensic purposes. Two investigators analyzed MRI images of the left hand and wrist of 77 male and 74 female caucasian subjects, without chronic diseases or developmental disorders, whose age ranged from 12 to 19 years. Skeletal maturation was determined by two operators, who analyzed all MRI images separately, in blinded fashion to the chronological age. Inter-rater agreement was measured with Pearson (R (2)) coefficient. One of the examiners repeated the evaluation after 6 months, and intraobserver variation was analyzed. Bland-Altman plots were used to determine mean differences between skeletal and chronological age. Inter-rater agreement Pearson coefficient showed a good linear correlation, respectively, 0.98 and 0.97 in males and females. Bland-Altman analysis demonstrated that the differences between chronological and skeletal age are not significant. Spearman's correlation coefficient showed good correlation between skeletal and chronological age both in females (R (2) = 0.96) and in males (R (2) = 0.94). Our results show that MRI skeletal age is a reproducible method and has good correlation with chronological age.
[Evaluation of the performances of the UF-1000i(®) automated urine analyzer].
Fabbro, Christelle; Darolles, Jacques; Rault, Jean-Philippe
2011-01-01
The purpose of this study was the evaluation of the UF 1000i(®) automated urine analyzer (bioMérieux(©)).The coefficients of variation (CV) for the repeatability of the red blood cell (RBC), white blood cell (WBC) and bacteria counts were overall concordant with those announced by the supplier. However, for low concentrations, the CV for the repeatability for concentrations of 10(3) RBC/mL, 10(3) WBC/mL and 5×10(3) UA/mL were respectively of 26, 18 and 36% and thus higher than the CV (10%) reported for each of the three parameters by the supplier. Reproducibility results agreed with those given by the supplier (10%). The linearity range was different from that reported by the supplier and was shifted by a factor 10 for WBC and bacteria high concentrations. Cross contamination between samples was prevented by using the washing program recommended by the supplier which however led to a lower analysis frequency (80 samples per hour). Detection limits were of 5,7×10(1) RBC/mL, 5,7×10(1) WBC/mL and 1,6×10(4) UA/mL respectively for the RBC, WBC and bacteria. Quantification limits found in this study were of 1,3×10(3) RBC/mL, 1,7×10(3) WBC/mL, 5,1×10(3) UA/mL. An overestimation of the RBC count was observed within the range of 5×10(3) to 2×10(4) RBC/mL. Beyond this concentration range, the concordance is good. The correlation is poor within this range and good for higher concentrations. For WBC, concordance and correlation were satisfactory over the whole range tested.
Háková, Martina; Raabová, Hedvika; Havlíková, Lucie Chocholoušová; Chocholouš, Petr; Chvojka, Jiří; Šatínský, Dalibor
2018-05-01
Nylon 6 nanofibers were tested for their ability to serve as a sorbent for solid phase extraction (SPE). The regular nanostructure providing a great sorption area and amidic functionality should lead to the assumption that nylon 6 nanofibers could be used as a novel sorbent with great potential for sample pre-treatment. However, due to the substantial differences between classical particle sorbents used for solid phase extraction and nanofibers, it is necessary to evaluate this novel approach. This article describes three types of laboratory fabricated nylon 6 nanofibers with different surface density (5.04gm -2 , 3.90gm -2 and 0.75gm -2 ) and corresponding surface areas for solid phase extraction of several groups of compounds with different structural and physicochemical properties (parabens, steroids, flavonoids and pesticides). The nanofibers were created by needleless electrospinning. Extraction columns were manually packed in classic 1- or 3-mL plastic syringe cartridges with 26-30mg of nanofibers and the column bed was sealed with polypropylene frits. The SPE procedure followed a typical five-step protocol and the collected eluates were analyzed by HPLC with UV detection. Extraction recovery was used as a parameter to evaluate the behavior of the analytes within the SPE process. Under this set condition, the recovery of the SPE process ranged from 23.1% to 125.8%. SPE showed good repeatability (0.58-11.87% RSD) and inter-day reproducibility (3.86-9.79% RSD). The achieved results were compared with SPE using a classic particle sorbent column. Good mechanical and chemical stability of nanofibers was proved. Scanning electron microscope was used for the evaluation of morphological changes in nanostructure. Nylon 6 nanofibers proved being a cost-effective sorbent for repeated use in SPE. Nylon 6 nanofibers have great potential in miniaturized SPE enabling users to overcome troubles with high back-pressure. Copyright © 2018 Elsevier B.V. All rights reserved.
Kamphuis, Vivian P; Westenberg, Jos J M; van der Palen, Roel L F; van den Boogaard, Pieter J; van der Geest, Rob J; de Roos, Albert; Blom, Nico A; Roest, Arno A W; Elbaz, Mohammed S M
2018-01-05
The aim of the current study was to assess the scan-rescan reproducibility of left ventricular (LV) kinetic energy (KE), viscous energy loss (EL) and vorticity during diastole from four-dimensional flow magnetic resonance imaging (4D flow MRI) in healthy subjects. Twelve volunteers (age 27 ± 3 years) underwent whole-heart 4D flow MRI twice in one session. In-scan consistency was evaluated by correlation between KE and EL. EL index was computed to measure the amount of EL relative to KE over diastole. Scan-rescan analysis was performed to test reproducibility of volumetric measurements of KE, EL, EL index and vorticity in the LV over early (E) and late (A) diastolic filling. In-scan consistency between KE and EL was strong-excellent (E-filling scan1: r = 0.92, P < 0.001; scan2: ρ = 0.96, P < 0.001 and A-filling scan1: ρ = 0.87, P < 0.001; scan2: r = 0.99, P < 0.001). For the majority of subjects (10 out of 12), KE and EL measures showed good to strong reproducibility. However, with a wide range of agreement [intraclass correlation (ICC): 0.64-0.95] and coefficients of variation (CV) ≤ 25%. EL index showed strong reproducibility for all 12 subjects with a strong ICC (0.94, P < 0.001) and a CV of 9%. Scan-rescan reproducibility of volumetric vorticity showed good-excellent ICCs (0.83-0.95) with CVs ≤ 11%. In conclusion, the current study shows strong-excellent in-scan consistency and overall good agreement between scans for 4D flow MRI assessment of left ventricular kinetic energy, energy loss and vorticity over diastole. However, substantial differences between the scans were also found in some parameters in two out of twelve subjects. Strong reproducibility was found in the dimensionless EL index , which measures the amount of viscous energy loss relative to the average kinetic energy over diastole.
Amano, Shiro; Honda, Norihiko; Amano, Yuki; Yamagami, Satoru; Miyai, Takashi; Samejima, Tomokazu; Ogata, Miyuki; Miyata, Kazunori
2006-06-01
To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. Experimental study. Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. Corneal thickness measurements were compared among the 3 methods in 54 eyes of 54 subjects. Two sets of measurements were repeated by a single examiner for each pachymetry in another 10 eyes of 5 subjects, and the intraexaminer repeatability was assessed as the absolute difference of the first and second measurements. Two experienced examiners took one measurement for each pachymetry in another 10 eyes of 5 subjects, and the interexaminer reproducibility was assessed as the absolute difference of the 2 measurements of the first and second examiners. Central corneal thickness measurements by the 3 methods, absolute difference of the first and second measurements by a single examiner, absolute difference of the 2 measurements by 2 examiners, and relative amount of variation. The average measurements of central corneal thickness by a rotating Scheimpflug camera, scanning-slit topography, and ultrasonic pachymetry were 538+/-31.3 microm, 541+/-40.7 microm, and 545+/-31.3 microm, respectively. There were no statistically significant differences in the measurement results among the 3 methods (P = 0.569, repeated-measures analysis of variance). There was a significant linear correlation between the rotating Scheimpflug camera and ultrasonic pachymetry (r = 0.908, P<0.0001), rotating Scheimpflug camera and scanning-slit topography (r = 0.930, P<0.0001), and ultrasonic pachymetry and scanning-slit topography (r = 0.887, P<0.0001). Ultrasonic pachymetry had the smallest intraexaminer variability, and scanning-slit topography had the largest intraexaminer variability among the 3 methods. There were similar variations in interexaminer reproducibility among the 3 methods. Mean corneal thicknesses were comparable among rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit topography with the acoustic equivalent correction factor. The measurements of the 3 instruments had significant linear correlations with one another, and all methods had highly satisfactory measurement repeatability.
Examining the Reproducibility of 6 Published Studies in Public Health Services and Systems Research.
Harris, Jenine K; B Wondmeneh, Sarah; Zhao, Yiqiang; Leider, Jonathon P
2018-02-23
Research replication, or repeating a study de novo, is the scientific standard for building evidence and identifying spurious results. While replication is ideal, it is often expensive and time consuming. Reproducibility, or reanalysis of data to verify published findings, is one proposed minimum alternative standard. While a lack of research reproducibility has been identified as a serious and prevalent problem in biomedical research and a few other fields, little work has been done to examine the reproducibility of public health research. We examined reproducibility in 6 studies from the public health services and systems research subfield of public health research. Following the methods described in each of the 6 papers, we computed the descriptive and inferential statistics for each study. We compared our results with the original study results and examined the percentage differences in descriptive statistics and differences in effect size, significance, and precision of inferential statistics. All project work was completed in 2017. We found consistency between original and reproduced results for each paper in at least 1 of the 4 areas examined. However, we also found some inconsistency. We identified incorrect transcription of results and omitting detail about data management and analyses as the primary contributors to the inconsistencies. Increasing reproducibility, or reanalysis of data to verify published results, can improve the quality of science. Researchers, journals, employers, and funders can all play a role in improving the reproducibility of science through several strategies including publishing data and statistical code, using guidelines to write clear and complete methods sections, conducting reproducibility reviews, and incentivizing reproducible science.
Potentiometric Zinc Ion Sensor Based on Honeycomb-Like NiO Nanostructures
Abbasi, Mazhar Ali; Ibupoto, Zafar Hussain; Hussain, Mushtaque; Khan, Yaqoob; Khan, Azam; Nur, Omer; Willander, Magnus
2012-01-01
In this study honeycomb-like NiO nanostructures were grown on nickel foam by a simple hydrothermal growth method. The NiO nanostructures were characterized by field emission electron microscopy (FESEM), high resolution transmission electron microscopy (HRTEM) and X-ray diffraction (XRD) techniques. The characterized NiO nanostructures were uniform, dense and polycrystalline in the crystal phase. In addition to this, the NiO nanostructures were used in the development of a zinc ion sensor electrode by functionalization with the highly selective zinc ion ionophore 12-crown-4. The developed zinc ion sensor electrode has shown a good linear potentiometric response for a wide range of zinc ion concentrations, ranging from 0.001 mM to 100 mM, with sensitivity of 36 mV/decade. The detection limit of the present zinc ion sensor was found to be 0.0005 mM and it also displays a fast response time of less than 10 s. The proposed zinc ion sensor electrode has also shown good reproducibility, repeatability, storage stability and selectivity. The zinc ion sensor based on the functionalized NiO nanostructures was also used as indicator electrode in potentiometric titrations and it has demonstrated an acceptable stoichiometric relationship for the determination of zinc ion in unknown samples. The NiO nanostructures-based zinc ion sensor has potential for analysing zinc ion in various industrial, clinical and other real samples. PMID:23202217
Chen, Jingyi; Zhu, Rong; Huang, Jia; Zhang, Man; Liu, Hongyu; Sun, Min; Wang, Li; Song, Yonghai
2015-08-21
A novel glucose biosensor was developed by immobilizing glucose oxidase (GOD) on a three-dimensional (3D) porous kenaf stem-derived carbon (3D-KSC) which was firstly proposed as a novel supporting material to load biomolecules for electrochemical biosensing. Here, an integrated 3D-KSC electrode was prepared by using a whole piece of 3D-KSC to load the GOD molecules for glucose biosensing. The morphologies of integrated 3D-KSC and 3D-KSC/GOD electrodes were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The SEM results revealed a 3D honeycomb macroporous structure of the integrated 3D-KSC electrode. The TEM results showed some microporosities and defects in the 3D-KSC electrode. The electrochemical behaviors and electrocatalytic performance of the integrated 3D-KSC/GOD electrode were evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. The effects of pH and scan rates on the electrochemical response of the biosensor have been studied in detail. The glucose biosensor showed a wide linear range from 0.1 mM to 14.0 mM with a high sensitivity of 1.73 μA mM(-1) and a low detection limit of 50.75 μM. Furthermore, the glucose biosensor exhibited high selectivity, good repeatability and reproducibility, and good stability.
Development of a pH sensing membrane electrode based on a new calix[4]arene derivative.
Kormalı Ertürün, H Elif; Demirel Özel, Ayça; Sayın, Serkan; Yılmaz, Mustafa; Kılıç, Esma
2015-01-01
A new pH sensing poly(vinyl chloride) (PVC) membrane electrode was developed by using recently synthesized 5,17-bis(4-benzylpiperidine-1-yl)methyl-25,26,27,28-tetrahydroxy calix[4]arene as an ionophore. The effects of membrane composition, inner filling solution and conditioning solution on the potential response of the proposed pH sensing membrane electrode were investigated. An optimum membrane composition of 3% ionophore, 67% o-nitrophenyl octyl ether (o-NPOE) as plasticizer, 30% PVC was found. The electrode exhibited a near-Nernstian slope of 58.7±1.1 mV pH(-1) in the pH range 1.9-12.7 at 20±1 °C. It showed good selectivity for H(+) ions in the presence of some cations and anions and a longer lifetime of at least 12 months when compared with the other PVC membrane pH electrodes reported in the literature. Having a wide working pH range, it was not only applied as a potentiometric indicator electrode in various acid-base titrations, but also successfully employed in different real samples. It has good reproducibility and repeatability with a response time of 6-7s. Compared to traditional glass pH electrode, it exhibited excellent potentiometric response after being used in fluoride-containing media. Copyright © 2014 Elsevier B.V. All rights reserved.
Martínez, C; Ramírez, N; Gómez, V; Pocurull, E; Borrull, F
2013-11-15
This study focuses on the development of an analytical method based on headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 76 micropollutants in water samples. The selected micropollutants include volatile organic compounds (VOCs) (e.g. chlorobenzenes, chloroalkanes), endocrine disrupting compounds (EDCs) (e.g. bisphenol A and tributyl phosphate), odour compounds (e.g. limonene, phenol), fragrance allergens (e.g. geraniol, eugenol) and some pesticides (e.g. heptachlor, terbutryn). The experimental conditions affecting their extraction, such as the type of fibre, temperature and time of extraction, sample volume and ionic strength of the samples were optimized using HS-SPME. The method showed good linear range, reproducibility between days, repeatability and low detection limits (at ng L(-1) levels). The validated method has been applied to determine the target organic micropollutants in aqueous samples from different experimental research units of surface water, sea water, waste water and those effluents of advance membrane treatments. The optimized method showed good performance in the different types of samples studied. The analysis revealed the presence of several micropollutants at concentrations between 20 and 5000 μg L(-1), such as ethylbenzene, o-xylene, p-isopropilbenzene, D-limonene, citral and isoeugenol, due to the fact that these species are commonly used in domestic and industrial applications. © 2013 Elsevier B.V. All rights reserved.
Wang, Xiaozhong; Li, Xuwen; Li, Lanjie; Li, Min; Liu, Ying; Wu, Qian; Li, Peng; Jin, Yongri
2016-05-01
A simple and sensitive method for determination of three aconitum alkaloids and their metabolites in human plasma was developed using matrix solid-phase dispersion combined with vortex-assisted dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection. The plasma sample was directly purified by matrix solid-phase dispersion and the eluate obtained was concentrated and further clarified by vortex-assisted dispersive liquid-liquid microextraction. Some important parameters affecting the extraction efficiency, such as type and amount of dispersing sorbent, type and volume of elution solvent, type and volume of extraction solvent, salt concentration as well as sample solution pH, were investigated in detail. Under optimal conditions, the proposed method has good repeatability and reproducibility with intraday and interday relative standard deviations lower than 5.44 and 5.75%, respectively. The recoveries of the aconitum alkaloids ranged from 73.81 to 101.82%, and the detection limits were achieved within the range of 1.6-2.1 ng/mL. The proposed method offered the advantages of good applicability, sensitivity, simplicity, and feasibility, which makes it suitable for the determination of trace amounts of aconitum alkaloids in human plasma samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ding, Yiran; Huang, Yun; Zhao, Tingting; Cai, Qian; Luo, Yu; Huang, Bin; Zhang, Yuxia; Pan, Xuejun
2014-06-01
A method for the determination of five representative organic UV filters: ethylhexyl methoxycinnamate (EHMC), benzophenone-3 (BP-3), 4-methylbenzylidene camphor (4-MBC), octocrylene (OC), homosalate (HMS) in water was investigated. The method was ased on derivatization, solid phase extraction (SPE), followed by determination with gas chromatography-mass spectrometry (GC-MS). The variables involved in the derivatization of BP-3 and HMS were optimized, and SPE conditions were studied. For derivatization, 100 microL N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) was used as derivatization reagent and reacted with BP-3 and HMS at 100 degrees C for 100 min. For SPE, the pH value of water sample was adjusted to 3-5. The Oasis HLB cartridges were employed and the solution of ethyl acetate and dichloromethane (1 : 1, v/v) was used as the eluting solvent, and good recoveries of the target compounds were obtained. The limits of detection (LODs) and the limits of quantification (LOQs) for the five target compounds in water samples were 0.5-1.2 ng/L and 1.4-4.0 ng/L, respectively. The recoveries of spiked water samples were 87.85%-102.34% with good repeatability and reproducibility (RSD < 5%, n = 3) for all the target compounds. Finally, the validated method was applied to analysis the representative UV filters in water samples collected from a wastewater treatment plant in Kunming city of Yunnan province.
Poor methodological detail precludes experimental repeatability and hampers synthesis in ecology.
Haddaway, Neal R; Verhoeven, Jos T A
2015-10-01
Despite the scientific method's central tenets of reproducibility (the ability to obtain similar results when repeated) and repeatability (the ability to replicate an experiment based on methods described), published ecological research continues to fail to provide sufficient methodological detail to allow either repeatability of verification. Recent systematic reviews highlight the problem, with one example demonstrating that an average of 13% of studies per year (±8.0 [SD]) failed to report sample sizes. The problem affects the ability to verify the accuracy of any analysis, to repeat methods used, and to assimilate the study findings into powerful and useful meta-analyses. The problem is common in a variety of ecological topics examined to date, and despite previous calls for improved reporting and metadata archiving, which could indirectly alleviate the problem, there is no indication of an improvement in reporting standards over time. Here, we call on authors, editors, and peer reviewers to consider repeatability as a top priority when evaluating research manuscripts, bearing in mind that legacy and integration into the evidence base can drastically improve the impact of individual research reports.
Soukup, Viktor; Čapoun, Otakar; Cohen, Daniel; Hernández, Virginia; Babjuk, Marek; Burger, Max; Compérat, Eva; Gontero, Paolo; Lam, Thomas; MacLennan, Steven; Mostafid, A Hugh; Palou, Joan; van Rhijn, Bas W G; Rouprêt, Morgan; Shariat, Shahrokh F; Sylvester, Richard; Yuan, Yuhong; Zigeuner, Richard
2017-11-01
Tumour grade is an important prognostic indicator in non-muscle-invasive bladder cancer (NMIBC). Histopathological classifications are limited by interobserver variability (reproducibility), which may have prognostic implications. European Association of Urology NMIBC guidelines suggest concurrent use of both 1973 and 2004/2016 World Health Organization (WHO) classifications. To compare the prognostic performance and reproducibility of the 1973 and 2004/2016 WHO grading systems for NMIBC. A systematic literature search was undertaken incorporating Medline, Embase, and the Cochrane Library. Studies were critically appraised for risk of bias (QUIPS). For prognosis, the primary outcome was progression to muscle-invasive or metastatic disease. Secondary outcomes were disease recurrence, and overall and cancer-specific survival. For reproducibility, the primary outcome was interobserver variability between pathologists. Secondary outcome was intraobserver variability (repeatability) by the same pathologist. Of 3593 articles identified, 20 were included in the prognostic review; three were eligible for the reproducibility review. Increasing tumour grade in both classifications was associated with higher disease progression and recurrence rates. Progression rates in grade 1 patients were similar to those in low-grade patients; progression rates in grade 3 patients were higher than those in high-grade patients. Survival data were limited. Reproducibility of the 2004/2016 system was marginally better than that of the 1973 system. Two studies on repeatability showed conflicting results. Most studies had a moderate to high risk of bias. Current grading classifications in NMIBC are suboptimal. The 1973 system identifies more aggressive tumours. Intra- and interobserver variability was slightly less in the 2004/2016 classification. We could not confirm that the 2004/2016 classification outperforms the 1973 classification in prediction of recurrence and progression. This article summarises the utility of two different grading systems for non-muscle-invasive bladder cancer. Both systems predict progression and recurrence, although pathologists vary in their reporting; suggestions for further improvements are made. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Coelho, Pedro G; Hollister, Scott J; Flanagan, Colleen L; Fernandes, Paulo R
2015-03-01
Bone scaffolds for tissue regeneration require an optimal trade-off between biological and mechanical criteria. Optimal designs may be obtained using topology optimization (homogenization approach) and prototypes produced using additive manufacturing techniques. However, the process from design to manufacture remains a research challenge and will be a requirement of FDA design controls to engineering scaffolds. This work investigates how the design to manufacture chain affects the reproducibility of complex optimized design characteristics in the manufactured product. The design and prototypes are analyzed taking into account the computational assumptions and the final mechanical properties determined through mechanical tests. The scaffold is an assembly of unit-cells, and thus scale size effects on the mechanical response considering finite periodicity are investigated and compared with the predictions from the homogenization method which assumes in the limit infinitely repeated unit cells. Results show that a limited number of unit-cells (3-5 repeated on a side) introduce some scale-effects but the discrepancies are below 10%. Higher discrepancies are found when comparing the experimental data to numerical simulations due to differences between the manufactured and designed scaffold feature shapes and sizes as well as micro-porosities introduced by the manufacturing process. However good regression correlations (R(2) > 0.85) were found between numerical and experimental values, with slopes close to 1 for 2 out of 3 designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Rezaei, Babak; Shoushtari, Ahmad Mousavi; Rabiee, Mohammad; Uzun, Lokman; Mak, Wing Cheung; Turner, Anthony P F
2018-05-15
A sandwich-type nanostructured immunosensor based on carboxylated multi-walled carbon nanotube (CMWCNT)-embedded whiskered nanofibres (WNFs) was developed for detection of cardiac Troponin I (cTnI). WNFs were directly fabricated on glassy carbon electrodes (GCE) by removing the sacrificial component (polyethylene glycol, PEG) after electrospinning of polystyrene/CMWCNT/PEG nanocomposite nanofibres, and utilised as a transducer layer for enzyme-labeled amperometric immunoassay of cTnI. The whiskered segments of CMWCNTs were activated and utilised to immobilise anti-cTnT antibodies. It was observed that the anchored CMWCNTs within the nanofibres were suitably stabilised with excellent electrochemical repeatability. A sandwich-type immuno-complex was formed between cTnI and horseradish peroxidase-conjugated anti-cTnI (HRP-anti-cTnI). The amperometric responses of the immunosensor were studied using cyclic voltammetry (CV) through an enzymatic reaction between hydrogen peroxide and HRP conjugated to the secondary antibody. The nanostructured immunosensor delivered a wide detection range for cTnI from the clinical borderline for a normal person (0.5-2ngmL -1 ) to the concentration present in myocardial infarction patients (> 20ngmL -1 ), with a detection limit of ~ 0.04ngmL -1 . It also showed good reproducibility and repeatability for three different cTnI concentration (1, 10 and 25ngmL -1 ) with satisfactory relative standard deviations (RSD). Hence, the proposed nanostructured immunosensor shows potential for point-of-care testing. Copyright © 2018 Elsevier B.V. All rights reserved.
Development and validation of new SSR markers from expressed regions in the garlic genome
USDA-ARS?s Scientific Manuscript database
Limited number of simple sequence repeat (SSR) markers is available for the genome of garlic (Allium sativum L.) although SSR markers have become one of the most preferred marker systems because they are typically co-dominant, reproducible, cross species transferable and highly polymorphic. In this ...
Many PCR-based methods for microbial source tracking (MST) have been developed and validated within individual research laboratories. Inter-laboratory validation of these methods, however, has been minimal, and the effects of protocol standardization regimes have not been thor...
Stress Training and Simulator Complexity: Why Sometimes More Is Less
ERIC Educational Resources Information Center
Tichon, Jennifer G.; Wallis, Guy M.
2010-01-01
Through repeated practice under conditions similar to those in real-world settings, simulator training prepares an individual to maintain effective performance under stressful work conditions. Interfaces offering high fidelity and immersion can more closely reproduce real-world experiences and are generally believed to result in better learning…
Gąsior, Jakub S.; Sacha, Jerzy; Jeleń, Piotr J.; Zieliński, Jakub; Przybylski, Jacek
2016-01-01
Background: Since heart rate variability (HRV) is associated with average heart rate (HR) and respiratory rate (RespRate), alterations in these parameters may impose changes in HRV. Hence the repeatability of HRV measurements may be affected by differences in HR and RespRate. The study aimed to evaluate HRV repeatability and its association with changes in HR and RespRate. Methods: Forty healthy volunteers underwent two ECG examinations 7 days apart. Standard HRV indices were calculated from 5-min ECG recordings. The ECG-derived respiration signal was estimated to assess RespRate. To investigate HR impact on HRV, HRV parameters were corrected for prevailing HR. Results: Differences in HRV parameters between the measurements were associated with the changes in HR and RespRate. However, in multiple regression analysis only HR alteration proved to be independent determinant of the HRV differences—every change in HR by 1 bpm changed HRV values by 16.5% on average. After overall removal of HR impact on HRV, coefficients of variation of the HRV parameters significantly dropped on average by 26.8% (p < 0.001), i.e., by the same extent HRV reproducibility improved. Additionally, the HRV correction for HR decreased association between RespRate and HRV. Conclusions: In stable conditions, HR but not RespRate is the most powerful factor determining HRV reproducibility and even a minimal change of HR may considerably alter HRV. However, the removal of HR impact may significantly improve HRV repeatability. The association between HRV and RespRate seems to be, at least in part, HR dependent. PMID:27588006
Prospective assessment of interobserver agreement for defecography in fecal incontinence.
Dobben, Annette C; Wiersma, Tjeerd G; Janssen, Lucas W M; de Vos, Rien; Terra, Maaike P; Baeten, Cor G; Stoker, Jaap
2005-11-01
The primary aim of our study was to determine the interobserver agreement of defecography in diagnosing enterocele, anterior rectocele, intussusception, and anismus in fecal-incontinent patients. The subsidiary aim was to evaluate the influence of level of experience on interpreting defecography. Defecography was performed in 105 consecutive fecal-incontinent patients. Observers were classified by level of experience and their findings were compared with the findings of an expert radiologist. The quality of the expert radiologist's findings was evaluated by an intraobserver agreement procedure. Intraobserver agreement was good to very good except for anismus: incomplete evacuation after 30 sec (kappa, 0.55) and puborectalis impression (kappa, 0.54). Interobserver agreement for enterocele and rectocele was good (kappa, 0.66 for both) and for intussusception, fair (kappa, 0.29). Interobserver agreement for anismus: incomplete evacuation after 30 sec was moderate (kappa, 0.47), and for anismus: puborectalis impression was fair (kappa, 0.24). Agreement in grading of enterocele and rectocele was good (kappa, 0.64 and 0.72, respectively) and for intussusception, fair (kappa, 0.39). Agreement separated by experience level was very good for rectocele (kappa, 0.83) and grading of rectoceles (kappa, 0.83) and moderate for intussusception (kappa, 0.44) at the most experienced level. For enterocele and grading, experience level did not influence the reproducibility. Reproducibility for enterocele, anterior rectocele, and severity grading is good, but for intussusception is fair to moderate. For anismus, the diagnosis of incomplete evacuation after 30 sec is more reproducible than puborectalis impression. The level of experience seems to play a role in diagnosing anterior rectocele and its grading and in diagnosing intussusception.
Guber, Ivo; Bachmann, Lucas M; Guber, Josef; Bochmann, Frank; Lange, Alex P; Thiel, Michael A
2011-09-01
Straylight gives the appearance of a veil of light thrown over a person's retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects' age. Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21-59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85-1.1). Per 10 years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p < 0.01]. We found no independent association of refraction (range -5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI -0.022 to 0.024, p = 0.92). Compared to emmetropic subjects, myopia reduced straylight (-.011; -0.024 to 0.02, p = 0.11), whereas higher straylight values (0.09; -0.01 to 0.20, p = 0.09) were observed in subjects with blue irises as compared to dark-colored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of vision.
Gray, Allan; Wright, Alex; Jackson, Pete; Hale, Mike; Treanor, Darren
2015-03-01
Histochemical staining of tissue is a fundamental technique in tissue diagnosis and research, but it suffers from significant variability. Efforts to address this include laboratory quality controls and quality assurance schemes, but these rely on subjective interpretation of stain quality, are laborious and have low reproducibility. We aimed (1) to develop a method for histochemical stain quantification using whole slide imaging and image analysis and (2) to demonstrate its usefulness in measuring staining variation. A method to quantify the individual stain components of histochemical stains on virtual slides was developed. It was evaluated for repeatability and reproducibility, then applied to control sections of an appendix to quantify H&E staining (H/E intensities and H:E ratio) between automated staining machines and to measure differences between six regional diagnostic laboratories. The method was validated with <0.5% variation in H:E ratio measurement when using the same scanner for a batch of slides (ie, it was repeatable) but was not highly reproducible between scanners or over time, where variation of 7% was found. Application of the method showed H:E ratios between three staining machines varied from 0.69 to 0.93, H:E ratio variation over time was observed. Interlaboratory comparison demonstrated differences in H:E ratio between regional laboratories from 0.57 to 0.89. A simple method using whole slide imaging can be used to quantify and compare histochemical staining. This method could be deployed in routine quality assurance and quality control. Work is needed on whole slide imaging devices to improve reproducibility. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Zhao, Hongjuan; Hastie, Trevor; Whitfield, Michael L; Børresen-Dale, Anne-Lise; Jeffrey, Stefanie S
2002-01-01
Background T7 based linear amplification of RNA is used to obtain sufficient antisense RNA for microarray expression profiling. We optimized and systematically evaluated the fidelity and reproducibility of different amplification protocols using total RNA obtained from primary human breast carcinomas and high-density cDNA microarrays. Results Using an optimized protocol, the average correlation coefficient of gene expression of 11,123 cDNA clones between amplified and unamplified samples is 0.82 (0.85 when a virtual array was created using repeatedly amplified samples to minimize experimental variation). Less than 4% of genes show changes in expression level by 2-fold or greater after amplification compared to unamplified samples. Most changes due to amplification are not systematic both within one tumor sample and between different tumors. Amplification appears to dampen the variation of gene expression for some genes when compared to unamplified poly(A)+ RNA. The reproducibility between repeatedly amplified samples is 0.97 when performed on the same day, but drops to 0.90 when performed weeks apart. The fidelity and reproducibility of amplification is not affected by decreasing the amount of input total RNA in the 0.3–3 micrograms range. Adding template-switching primer, DNA ligase, or column purification of double-stranded cDNA does not improve the fidelity of amplification. The correlation coefficient between amplified and unamplified samples is higher when total RNA is used as template for both experimental and reference RNA amplification. Conclusion T7 based linear amplification reproducibly generates amplified RNA that closely approximates original sample for gene expression profiling using cDNA microarrays. PMID:12445333
Cai, Jing; Read, Paul W; Altes, Talissa A; Molloy, Janelle A; Brookeman, James R; Sheng, Ke
2007-01-21
Treatment planning based on probability distribution function (PDF) of patient geometries has been shown a potential off-line strategy to incorporate organ motion, but the application of such approach highly depends upon the reproducibility of the PDF. In this paper, we investigated the dependences of the PDF reproducibility on the imaging acquisition parameters, specifically the scan time and the frame rate. Three healthy subjects underwent a continuous 5 min magnetic resonance (MR) scan in the sagittal plane with a frame rate of approximately 10 f s-1, and the experiments were repeated with an interval of 2 to 3 weeks. A total of nine pulmonary vessels from different lung regions (upper, middle and lower) were tracked and the dependences of their displacement PDF reproducibility were evaluated as a function of scan time and frame rate. As results, the PDF reproducibility error decreased with prolonged scans and appeared to approach equilibrium state in subjects 2 and 3 within the 5 min scan. The PDF accuracy increased in the power function with the increase of frame rate; however, the PDF reproducibility showed less sensitivity to frame rate presumably due to the randomness of breathing which dominates the effects. As the key component of the PDF-based treatment planning, the reproducibility of the PDF affects the dosimetric accuracy substantially. This study provides a reference for acquiring MR-based PDF of structures in the lung.
NASA Astrophysics Data System (ADS)
Li, Zhenzhen; Chen, Yan; Xin, Yanmei; Zhang, Zhonghai
2015-11-01
In this work, we proposed to utilize three-dimensional porous copper foam (CF) as conductive substrate and precursor of in-situ growth CuO nanowires (NWs) for fabricating electrochemical nonenzymatic glucose sensors. The CF supplied high surface area due to its unique three-dimensional porous foam structure, and thus resulted in high sensitivity for glucose detection. The CuO NWs/CF based nonenzymatic sensors presented reliable selectivity, good repeatability, reproducibility, and stability. In addition, the CuO NWs/CF based nonenzymatic sensors have been employed for practical applications, and the glucose concentration in human serum was measured to be 4.96 ± 0.06 mM, agreed well with the value measured from the commercial available glucose sensor in hospital, and the glucose concentration in saliva was also estimated to be 0.91 ± 0.04 mM, which indicated that the CuO NWs/CF owned the possibility for noninvasive glucose detection. The rational design of CuO NWs/CF provided an efficient strategy for fabricating of electrochemical nonenzymatic biosensors.
NASA Astrophysics Data System (ADS)
Jafari, Marzieh; Tashkhourian, Javad; Absalan, Ghodratollah
2017-10-01
A simple, fast and green method for chiral recognition of S- and R-naproxen has been introduced. The method was based on quenching of the fluorescence intensity of bovine serum albumin-stabilized gold nanoclusters in the presence of naproxen enantiomers. The quenching intensity in the presence of S-naproxen was higher than R-naproxen when phosphate buffer solution at pH 7.0 was used. The chiral recognition occurred due to steric effect between bovine serum albumin conformation and naproxen enantiomers. Two linear determination range were established as 7.4 × 10-7-9.1 × 10-6 and 9.1 × 10-6-3.1 × 10-5 mol L-1 for both enantiomers and detection limits of 7.4 × 10-8 mol L- 1 and 9.5 × 10-8 mol L-1 were obtained for S- and R-naproxen, respectively. The developed method showed good repeatability and reproducibility for the analysis of a synthetic sample. To make the procedure applicable to biological samples, the removal of heavy metals from the sample is suggested before any analytical attempt.
Liyanaarachchi, G V V; Mahanama, K R R; Somasiri, H P P S; Punyasiri, P A N
2018-02-01
The study presents the validation results of the method carried out for analysis of free amino acids (FAAs) in rice using l-theanine as the internal standard (IS) with o-phthalaldehyde (OPA) reagent using high-performance liquid chromatography-fluorescence detection. The detection and quantification limits of the method were in the range 2-16μmol/kg and 3-19μmol/kg respectively. The method had a wide working range from 25 to 600μmol/kg for each individual amino acid, and good linearity with regression coefficients greater than 0.999. Precision measured in terms of repeatability and reproducibility, expressed as percentage relative standard deviation (% RSD) was below 9% for all the amino acids analyzed. The recoveries obtained after fortification at three concentration levels were in the range 75-105%. In comparison to l-norvaline, findings revealed that l-theanine is suitable as an IS and the validated method can be used for FAA determination in rice. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kikuchi, Hiroyuki; Tsutsumi, Tomoaki; Matsuda, Rieko
2012-01-01
A method for the quantification of histamine in fish and fish products using tandem solid-phase extraction and fluorescence derivatization with fluorescamine was previously developed. In this study, we improved this analytical method to develop an official test method for quantification of histamine in fish and fish products, and performed a single laboratory study to validate it. Recovery tests of histamine from fillet (Thunnus obesus), and two fish products (fish sauce and salted and dried whole big-eye sardine) that were spiked at the level of 25 and 50 µg/g for T. obesus, and 50 and 100 µg/g for the two fish products, were carried out. The recoveries of histamine from the three samples tested were 88.8-99.6% with good repeatability (1.3-2.1%) and reproducibility (2.1-4.7%). Therefore, this method is acceptable for the quantification of histamine in fish and fish products. Moreover, surveillance of histamine content in food on the market was conducted using this method, and high levels of histamine were detected in some fish products.
Magne, S; Auger, L; Bordy, J M; de Carlan, L; Isambert, A; Bridier, A; Ferdinand, P; Barthe, J
2008-01-01
This article proposes an innovative multichannel optically stimulated luminescence (OSL) dosemeter for on-line in vivo dose verification in radiation therapy. OSL fibre sensors incorporating small Al(2)O(3):C fibre crystals (TLD(500)) have been tested with an X-ray generator. A reproducible readout procedure should reduce the fading-induced uncertainty ( approximately - 1% per decade). OSL readouts are temperature-dependent [ approximately 0.3% K(-1) when OSL stimulation is performed at the same temperature as irradiation; approximately 0.16% K(-1) after thermalisation (20 degrees C)]. Sensor calibration and depth-dose measurements with electron beams have been performed with a Saturne 43 linear accelerator in reference conditions at CEA-LNHB (ionising radiation reference laboratory in France). Predosed OSL sensors show a good repeatability in multichannel operation and independence versus electron energy in the range (9, 18 MeV). The difference between absorbed doses measured by OSL and an ionisation chamber were within +/-0.9% (for a dose of about 1 Gy) despite a sublinear calibration curve.
Ciftci, Hakan; Oztekin, Yasemin; Tamer, Ugur; Ramanaviciene, Almira; Ramanavicius, Arunas
2014-11-01
This study is focused on the investigation of electrocatalytic effect of glucose oxidase (GOx) immobilized on the graphite rod (GR) electrode. The enzyme modified electrode was prepared by encapsulation of immobilized GOx within enzymatically formed poly(1,10-phenanthroline-5,6-dione) (pPD) film. The electrochemical responses of such enzymatic electrode (pPD/GOx/GR) vs. different glucose concentrations were examined chronoamperometrically in acetate-phosphate buffer solution (A-PBS), pH 6.0, under aerobic or anaerobic conditions. Amperometric signals of the pPD/GOx/GR electrode exhibited well-defined hyperbolic dependence upon glucose concentration. Amperometric signals at 100mM of glucose were 41.17 and 32.27 μA under aerobic and anaerobic conditions, respectively. Amperometric signals of the pPD/GOx/GR electrode decreased by 6% within seven days. The pPD/GOx/GR electrode showed excellent selectivity in the presence of dopamine and uric acid. Furthermore it had a good reproducibility and repeatability with standard deviation of 9.4% and 8.0%, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.
Miniaturized pH Sensors Based on Zinc Oxide Nanotubes/Nanorods
Fulati, Alimujiang; Ali, Syed M.Usman; Riaz, Muhammad; Amin, Gul; Nur, Omer; Willander, Magnus
2009-01-01
ZnO nanotubes and nanorods grown on gold thin film were used to create pH sensor devices. The developed ZnO nanotube and nanorod pH sensors display good reproducibility, repeatability and long-term stability and exhibit a pH-dependent electrochemical potential difference versus an Ag/AgCl reference electrode over a large dynamic pH range. We found the ZnO nanotubes provide sensitivity as high as twice that of the ZnO nanorods, which can be ascribed to the fact that small dimensional ZnO nanotubes have a higher level of surface and subsurface oxygen vacancies and provide a larger effective surface area with higher surface-to-volume ratio as compared to ZnO nanorods, thus affording the ZnO nanotube pH sensor a higher sensitivity. Experimental results indicate ZnO nanotubes can be used in pH sensor applications with improved performance. Moreover, the ZnO nanotube arrays may find potential application as a novel material for measurements of intracellular biochemical species within single living cells. PMID:22291545
Lo Dico, Gianluigi Maria; Galvano, Fabio; Dugo, Giacomo; D'ascenzi, Carlo; Macaluso, Andrea; Vella, Antonio; Giangrosso, Giuseppe; Cammilleri, Gaetano; Ferrantelli, Vincenzo
2018-04-15
The Commission Regulation (EC) Regulation N. 488/2014, established the concentration limits for cadmium in specific products based on cocoa and chocolate products as from January 2019. Based on this information there is a need to determine ultratrace levels of elements that might be presents in cocoa and chocolate products. In this work, the concentrations of Arsenic, Antimony, Cadmium, Chromium, Lead, Selenium and Vanadium were evaluated in cocoa powder and chocolate by the validation of an ICP-MS method. Good selectivity/specificity, recovery, repeatability and within-laboratory reproducibility, LOD, LOQ, range of linearity, standard measurement uncertainty parameters for method validation were achieved, in accordance with Commission Regulation. The cocoa powder revealed the maximum metal concentrations of 0.303 ± 0.035 mg/kg for cadmium, 1.228 ± 0.146 mg/kg for lead and 0.094 ± 0.013 mg/kg for arsenic. A significant difference was found between cocoa powder and chocolate samples (p < .05). Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Msagati, Titus A. M.; Mamba, Bhekie B.
The supported liquid membrane (SLM) extraction technique has been developed and successfully used for the monitoring of trace quantities of ionisable organic contaminants, including 17β-estradiol and its metabolites, testosterones and their methyl ester derivatives, benzimidazole anthelmintic antibiotics and sulphonamides in aquatic systems. A number of parameters which control the mass transfer in the supported liquid membrane extraction process such as donor and acceptor pH, extraction time and the type of organic liquid membrane were optimised to enhance the efficiency of the liquid membrane in the removal of these compounds. The method developed gave very low detection limits (0.3 ng/l to 2.4 ng/l for 17β-estradiol and its metabolites; between 1 μg/l and 20 μg/l for sulphonamides; and between 0.1 ng/l and 10 ng/l for benzimidazole anthelmintic compounds). The SLM method showed good linearity, reproducibility and repeatability values and is therefore suitable for routine monitoring of such compounds in water and wastewater systems.
NASA Astrophysics Data System (ADS)
Morales-Muñoz, S.; Luque-García, J. L.; Luque de Castro, M. D.
2003-01-01
Acidified and pressurized hot water is proposed for the continuous leaching of Cd and Pb from plants prior to determination by electrothermal atomic absorption spectrometry. Beech leaves (a certified reference material—CRM 100—where the analytes were not certified) were used for optimizing the method by a multivariate approach. The samples (0.5 g) were subjected to dynamic extraction with water modified with 1% v/v HNO 3 at 250 °C as leachant. A kinetics study was performed in order to know the pattern of the extraction process. The method was validated with a CRM (olive leaves, 062 from the BCR) where the analytes had been certified. The agreement between the certified values and those found using the proposed method demonstrates its usefulness. The repeatability and within-laboratory reproducibility were 3.7 and 2.3% for Cd and 1.04% and 6.3% for Pb, respectively. The precision of the method, together with its efficiency, rapidity, and environmental acceptability, makes it a good alternative for the determination of trace metals in plant material.
Flexible strain sensors with high performance based on metallic glass thin film
NASA Astrophysics Data System (ADS)
Xian, H. J.; Cao, C. R.; Shi, J. A.; Zhu, X. S.; Hu, Y. C.; Huang, Y. F.; Meng, S.; Gu, L.; Liu, Y. H.; Bai, H. Y.; Wang, W. H.
2017-09-01
Searching strain sensitive materials for electronic skin is of crucial significance because of the restrictions of current materials such as poor electrical conductivity, large energy consumption, complex manufacturing process, and high cost. Here, we report a flexible strain sensor based on the Zr55Cu30Ni5Al10 metallic glass thin film which we name metallic glass skin. The metallic glass skin, synthesized by ion beam deposition, exhibits piezoresistance effects with a gauge factor of around 2.86, a large detectable strain range (˜1% or 180° bending angle), and good conductivity. Compared to other e-skin materials, the temperature coefficient of resistance of the metallic glass skin is extremely low (9.04 × 10-6 K-1), which is essential for the reduction in thermal drift. In addition, the metallic glass skin exhibits distinct antibacterial behavior desired for medical applications, also excellent reproducibility and repeatability (over 1000 times), nearly perfect linearity, low manufacturing cost, and negligible energy consumption, all of which are required for electronic skin for practical applications.
Li, Zhenzhen; Chen, Yan; Xin, Yanmei; Zhang, Zhonghai
2015-01-01
In this work, we proposed to utilize three-dimensional porous copper foam (CF) as conductive substrate and precursor of in-situ growth CuO nanowires (NWs) for fabricating electrochemical nonenzymatic glucose sensors. The CF supplied high surface area due to its unique three-dimensional porous foam structure, and thus resulted in high sensitivity for glucose detection. The CuO NWs/CF based nonenzymatic sensors presented reliable selectivity, good repeatability, reproducibility, and stability. In addition, the CuO NWs/CF based nonenzymatic sensors have been employed for practical applications, and the glucose concentration in human serum was measured to be 4.96 ± 0.06 mM, agreed well with the value measured from the commercial available glucose sensor in hospital, and the glucose concentration in saliva was also estimated to be 0.91 ± 0.04 mM, which indicated that the CuO NWs/CF owned the possibility for noninvasive glucose detection. The rational design of CuO NWs/CF provided an efficient strategy for fabricating of electrochemical nonenzymatic biosensors. PMID:26522446
Hydrothermal growth of CuO nanoleaf structures, and their mercuric ion detection application.
Ibupoto, Z H; Khun, K; Willander, M
2014-09-01
Mercury is the hazardous heavy metal ion for the environment and the human being therefore its determination is very important and herein we describe the development of mercury ion sensor on the CuO nanoleaf like nanostructures using cetyltrimethylammonium bromide (CTAB) surfactant as template for the growth by hydrothermal growth method. Scanning electron microscopy and X-ray diffraction study has shown high density and good crystal quality of the fabricated CuO nanostructures respectively. The presented mercury ion sensor has detected the wide range of 1.0 x 10(-7) to 1.0 x 10(-1) M mercury ion concentrations with an acceptable Nernstian behaviour and a sensitivity of 30.1 ± 0.6 mV/decade. The proposed mercury ion sensor exhibited low detection limit of 1.0 x 10(-8) M and also a fast response time of less than 5 s. In addition, the presented mercury ion sensor has shown an excellent repeatability, reproducibility, stability and selectivity. Moreover, the mercury ion selective electrode based on CuO nanoleaves was tested as an indicator electrode in the potentiometric titration.
Miró-Abella, Eugènia; Herrero, Pol; Canela, Núria; Arola, Lluís; Borrull, Francesc; Ras, Rosa; Fontanals, Núria
2017-08-15
A method was developed for the simultaneous determination of 11 mycotoxins in plant-based beverage matrices, using a QuEChERS extraction followed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry detection (UHPLC-(ESI)MS/MS). This multi-mycotoxin method was applied to analyse plant-based beverages such as soy, oat and rice. QuEChERS extraction was applied obtaining suitable extraction recoveries between 80 and 91%, and good repeatability and reproducibility values. Method Quantification Limits were between 0.05μgL -1 (for aflatoxin G 1 and aflatoxin B 1 ) and 15μgL -1 (for deoxynivalenol and fumonisin B 2 ). This is the first time that plant-based beverages have been analysed, and certain mycotoxins, such as deoxynivalenol, aflatoxin B 1 , aflatoxin B 2 , aflatoxin G 1 , aflatoxin G 2 , ochratoxin A, T-2 toxin and zearalenone, were found in the analysed samples, and some of them quantified between 0.1μgL -1 and 19μgL -1 . Copyright © 2017 Elsevier Ltd. All rights reserved.
Efficient generation of connectivity in neuronal networks from simulator-independent descriptions
Djurfeldt, Mikael; Davison, Andrew P.; Eppler, Jochen M.
2014-01-01
Simulator-independent descriptions of connectivity in neuronal networks promise greater ease of model sharing, improved reproducibility of simulation results, and reduced programming effort for computational neuroscientists. However, until now, enabling the use of such descriptions in a given simulator in a computationally efficient way has entailed considerable work for simulator developers, which must be repeated for each new connectivity-generating library that is developed. We have developed a generic connection generator interface that provides a standard way to connect a connectivity-generating library to a simulator, such that one library can easily be replaced by another, according to the modeler's needs. We have used the connection generator interface to connect C++ and Python implementations of the previously described connection-set algebra to the NEST simulator. We also demonstrate how the simulator-independent modeling framework PyNN can transparently take advantage of this, passing a connection description through to the simulator layer for rapid processing in C++ where a simulator supports the connection generator interface and falling-back to slower iteration in Python otherwise. A set of benchmarks demonstrates the good performance of the interface. PMID:24795620
Zheng, Juan; Liang, Yeru; Liu, Shuqin; Jiang, Ruifen; Zhu, Fang; Wu, Dingcai; Ouyang, Gangfeng
2016-01-04
A combination of nitrogen-doped ordered mesoporous polymer (NOMP) and stainless steel wires led to highly sensitive, selective, and stable solid phase microextraction (SPME) fibers by in situ polymerization for the first time. The ordered structure of synthesized NOMP coating was illustrated by transmission electron microscopy (TEM) and X-ray diffraction (XRD), and microscopy analysis by scanning electron microscopy (SEM) confirmed a homogenous morphology of the NOMP-coated fiber. The NOMP-coated fiber was further applied for the extraction of organochlorine pesticides (OCPs) with direct-immersion solid-phase microextraction (DI-SPME) method followed by gas chromatography-mass spectrometry (GC-MS) quantification. Under the optimized conditions, low detection limits (0.023-0.77 ng L(-1)), a wide linear range (9-1500 ng L(-1)), good repeatability (3.5-8.1%, n=6) and excellent reproducibility (1.5-8.3%, n=3) were achieved. Moreover, the practical feasibility of the proposed method was evaluated by determining OCPs in environmental water samples with satisfactory recoveries. Copyright © 2015 Elsevier B.V. All rights reserved.
Yang, Ya-Jun; Liu, Xi-Wang; Li, Bing; Li, Shi-Hong; Kong, Xiao-Jun; Qin, Zhe; Li, Jian-Yong
2016-12-01
This study developed and validated a simple and reliable method for detecting and quantifying DVD, TMP and OMP in feed using dichloromethane extraction followed by HPLC-MS/MS. A matrix effect evaluation was performed using the post-extraction spiking method, and levels were less than ±15% in all three feeds with their corresponding concentrations. LOD and LOQ, CCα and CCβ were 20μgkg(-1) and 40μgkg(-1), 8.68-15.55μgkg(-1) and 10.61-18.92μgkg(-1) for all analytes, respectively. Calibration curves were linear for DVD, TMP and OMP with R(2)⩾0.990 and r⩾0.995, respectively. Recoveries of low, medium and high concentrations using the proposed method ranged from 74.4 to 105.2%. Repeatability and within-laboratory reproducibility were <7.4% (RSD). The chosen seven factors had no a significant influence on robustness. The method showed good performance when it was applied to analyze other laboratory-prepared or actual feed samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Troise, Antonio Dario; Fiore, Alberto; Wiltafsky, Markus; Fogliano, Vincenzo
2015-12-01
The control of Maillard reaction (MR) is a key point to ensure processed foods quality. Due to the presence of a primary amino group on its side chain, lysine is particularly prone to chemical modifications with the formation of Amadori products (AP), Nε-(Carboxymethyl)-L-lysine (CML), Nε-(Carboxyethyl)-L-lysine (CEL). A new analytical strategy was proposed which allowed to simultaneously quantify lysine, CML, CEL and the Nε-(2-Furoylmethyl)-L-lysine (furosine), the indirect marker of AP. The procedure is based on stable isotope dilution assay followed by liquid chromatography tandem mass spectrometry. It showed high sensitivity and good reproducibility and repeatability in different foods. The limit of detection and the RSD% were lower than 5 ppb and below 8%, respectively. Results obtained with the new procedure not only improved the knowledge about the reliability of thermal treatment markers, but also defined new insights in the relationship between Maillard reaction products and their precursors. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gholivand, Mohammad Bagher; Mohammadi-Behzad, Leila
2015-12-01
A method is described for the construction of a novel electrochemical warfarin sensor based on covalent immobilization of CdS-quantum dots (CdS-QDs) onto carboxylated multiwalled carbon nanotubes/chitosan (CS) composite film on the surface of a glassy carbon electrode. The CdS-QDs/CS/MWCNTs were characterized by field-emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), Fourier transform infra-red (FTIR) spectroscopy, XRD analysis and electrochemical impedance spectroscopy (EIS). The sensor showed optimum anodic stripping response within 90s at an accumulation potential of 0.75V. The modified electrode was used to detect the concentration of warfarin with a wide linear range of 0.05-80 μM and a detection limit (S/N=3) of 8.5 nM. The proposed sensor has good storage stability, repeatability and reproducibility and was successfully applied for the determination of warfarin in real samples such as urine, serum and milk. Copyright © 2015. Published by Elsevier B.V.
Rollier, Patricia; Lombard, Bertrand; Guillier, Laurent; François, Danièle; Romero, Karol; Pierru, Sylvie; Bouhier, Laurence; Gnanou Besse, Nathalie
2018-05-01
The reference method for the detection and enumeration of L. monocytogenes in food (Standards EN ISO 11290-1&2) have been validated by inter-laboratory studies in the frame of the Mandate M381 from European Commission to CEN. In this paper, the inter-laboratory studies led in 2013 on 5 matrices (cold-smoked salmon, milk powdered infant food formula, vegetables, environment, and cheese) to validate Standard EN ISO 11290-2 are reported. According to the results obtained, the method of the revised Standard EN ISO 11290-2 can be considered as a good method for the enumeration of L. monocytogenes in foods and food processing environment, in particular for the matrices included in the study. Values of repeatability and reproducibility standard deviations can be considered satisfactory for this type of method with a confirmation stage, since most of them were below 0.3 log 10 , also at low levels, close to the regulatory limit of 100 CFU/g. Copyright © 2018 Elsevier B.V. All rights reserved.
Pierini, Gastón Darío; Pinto, Victor Hugo A; Maia, Clarissa G C; Fragoso, Wallace D; Reboucas, Julio S; Centurión, María Eugenia; Pistonesi, Marcelo Fabián; Di Nezio, María Susana
2017-11-01
The quantification of zinc in over-the-counter drugs as commercial propolis extracts by molecular fluorescence technique using meso-tetrakis(4-carboxyphenyl)porphyrin (H 2 TCPP 4 ) was developed for the first time. The calibration curve is linear from 6.60 to 100 nmol L -1 of Zn 2+ . The detection and quantification limits were 6.22 nmol L -1 and 19.0 nmol L -1 , respectively. The reproducibility and repeatability calculated as the percentage variation of slopes of seven calibration curves were 6.75% and 4.61%, respectively. Commercial propolis extract samples from four Brazilian states were analyzed and the results (0.329-0.797 mg/100 mL) obtained with this method are in good agreement with that obtained with the Atomic Absorption Spectroscopy (AAS) technique. The method is simple, fast, of low cost and allows the analysis of the samples without pretreatment. Moreover the major advantage is that Zn-porphyrin complex presents fluorescent characteristic promoting the selectivity and sensitivity of the method. Copyright © 2017 John Wiley & Sons, Ltd.
Reproducibility of airway luminal size in asthma measured by HRCT.
Brown, Robert H; Henderson, Robert J; Sugar, Elizabeth A; Holbrook, Janet T; Wise, Robert A
2017-10-01
Brown RH, Henderson RJ, Sugar EA, Holbrook JT, Wise RA, on behalf of the American Lung Association Airways Clinical Research Centers. Reproducibility of airway luminal size in asthma measured by HRCT. J Appl Physiol 123: 876-883, 2017. First published July 13, 2017; doi:10.1152/japplphysiol.00307.2017.-High-resolution CT (HRCT) is a well-established imaging technology used to measure lung and airway morphology in vivo. However, there is a surprising lack of studies examining HRCT reproducibility. The CPAP Trial was a multicenter, randomized, three-parallel-arm, sham-controlled 12-wk clinical trial to assess the use of a nocturnal continuous positive airway pressure (CPAP) device on airway reactivity to methacholine. The lack of a treatment effect of CPAP on clinical or HRCT measures provided an opportunity for the current analysis. We assessed the reproducibility of HRCT imaging over 12 wk. Intraclass correlation coefficients (ICCs) were calculated for individual airway segments, individual lung lobes, both lungs, and air trapping. The ICC [95% confidence interval (CI)] for airway luminal size at total lung capacity ranged from 0.95 (0.91, 0.97) to 0.47 (0.27, 0.69). The ICC (95% CI) for airway luminal size at functional residual capacity ranged from 0.91 (0.85, 0.95) to 0.32 (0.11, 0.65). The ICC measurements for airway distensibility index and wall thickness were lower, ranging from poor (0.08) to moderate (0.63) agreement. The ICC for air trapping at functional residual capacity was 0.89 (0.81, 0.94) and varied only modestly by lobe from 0.76 (0.61, 0.87) to 0.95 (0.92, 0.97). In stable well-controlled asthmatic subjects, it is possible to reproducibly image unstimulated airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. NEW & NOTEWORTHY There is a surprising lack of studies examining the reproducibility of high-resolution CT in asthma. The current study examined reproducibility of airway measurements. In stable well-controlled asthmatic subjects, it is possible to reproducibly image airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. Copyright © 2017 the American Physiological Society.
Effect of Initial Conditions on Reproducibility of Scientific Research
Djulbegovic, Benjamin; Hozo, Iztok
2014-01-01
Background: It is estimated that about half of currently published research cannot be reproduced. Many reasons have been offered as explanations for failure to reproduce scientific research findings- from fraud to the issues related to design, conduct, analysis, or publishing scientific research. We also postulate a sensitive dependency on initial conditions by which small changes can result in the large differences in the research findings when attempted to be reproduced at later times. Methods: We employed a simple logistic regression equation to model the effect of covariates on the initial study findings. We then fed the input from the logistic equation into a logistic map function to model stability of the results in repeated experiments over time. We illustrate the approach by modeling effects of different factors on the choice of correct treatment. Results: We found that reproducibility of the study findings depended both on the initial values of all independent variables and the rate of change in the baseline conditions, the latter being more important. When the changes in the baseline conditions vary by about 3.5 to about 4 in between experiments, no research findings could be reproduced. However, when the rate of change between the experiments is ≤2.5 the results become highly predictable between the experiments. Conclusions: Many results cannot be reproduced because of the changes in the initial conditions between the experiments. Better control of the baseline conditions in-between the experiments may help improve reproducibility of scientific findings. PMID:25132705
Effect of initial conditions on reproducibility of scientific research.
Djulbegovic, Benjamin; Hozo, Iztok
2014-06-01
It is estimated that about half of currently published research cannot be reproduced. Many reasons have been offered as explanations for failure to reproduce scientific research findings- from fraud to the issues related to design, conduct, analysis, or publishing scientific research. We also postulate a sensitive dependency on initial conditions by which small changes can result in the large differences in the research findings when attempted to be reproduced at later times. We employed a simple logistic regression equation to model the effect of covariates on the initial study findings. We then fed the input from the logistic equation into a logistic map function to model stability of the results in repeated experiments over time. We illustrate the approach by modeling effects of different factors on the choice of correct treatment. We found that reproducibility of the study findings depended both on the initial values of all independent variables and the rate of change in the baseline conditions, the latter being more important. When the changes in the baseline conditions vary by about 3.5 to about 4 in between experiments, no research findings could be reproduced. However, when the rate of change between the experiments is ≤2.5 the results become highly predictable between the experiments. Many results cannot be reproduced because of the changes in the initial conditions between the experiments. Better control of the baseline conditions in-between the experiments may help improve reproducibility of scientific findings.
An Open Science Peer Review Oath
Aleksic, Jelena; Alexa, Adrian; Attwood, Teresa K; Chue Hong, Neil; Dahlö, Martin; Davey, Robert; Dinkel, Holger; Förstner, Konrad U; Grigorov, Ivo; Hériché, Jean-Karim; Lahti, Leo; MacLean, Dan; Markie, Michael L; Molloy, Jenny; Schneider, Maria Victoria; Scott, Camille; Smith-Unna, Richard; Vieira, Bruno Miguel
2015-01-01
One of the foundations of the scientific method is to be able to reproduce experiments and corroborate the results of research that has been done before. However, with the increasing complexities of new technologies and techniques, coupled with the specialisation of experiments, reproducing research findings has become a growing challenge. Clearly, scientific methods must be conveyed succinctly, and with clarity and rigour, in order for research to be reproducible. Here, we propose steps to help increase the transparency of the scientific method and the reproducibility of research results: specifically, we introduce a peer-review oath and accompanying manifesto. These have been designed to offer guidelines to enable reviewers (with the minimum friction or bias) to follow and apply open science principles, and support the ideas of transparency, reproducibility and ultimately greater societal impact. Introducing the oath and manifesto at the stage of peer review will help to check that the research being published includes everything that other researchers would need to successfully repeat the work. Peer review is the lynchpin of the publishing system: encouraging the community to consciously (and conscientiously) uphold these principles should help to improve published papers, increase confidence in the reproducibility of the work and, ultimately, provide strategic benefits to authors and their institutions. PMID:25653839
Faber, Irene R; Nijhuis-Van Der Sanden, Maria W G; Elferink-Gemser, Marije T; Oosterveld, Frits G J
2015-01-01
A motor skills assessment could be helpful in talent development by estimating essential perceptuo-motor skills of young players, which are considered requisite to develop excellent technical and tactical qualities. The Netherlands Table Tennis Association uses a motor skills assessment in their talent development programme consisting of eight items measuring perceptuo-motor skills specific to table tennis under varying conditions. This study aimed to investigate this assessment regarding its reproducibility, internal consistency, underlying dimensions and concurrent validity in 113 young table tennis players (6-10 years). Intraclass correlation coefficients of six test items met the criteria of 0.7 with coefficients of variation between 3% and 8%. Cronbach's alpha valued 0.853 for internal consistency. The principal components analysis distinguished two conceptually meaningful factors: "ball control" and "gross motor function." Concurrent validity analyses demonstrated moderate associations between the motor skills assessment's results and national ranking; boys r = -0.53 (P < 0.001) and girls r = -0.45 (P = 0.015). In conclusion, this evaluation demonstrated six test items with acceptable reproducibility, good internal consistency and good prospects for validity. Two test items need revision to upgrade reproducibility. Since the motor skills assessment seems to be a reproducible, objective part of a talent development programme, more longitudinal studies are required to investigate its predictive validity.
Matschat, Ralf; Hassler, Jürgen; Traub, Heike; Dette, Angelika
2005-12-01
The members of the committee NMP 264 "Chemical analysis of non-oxidic raw and basic materials" of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to "the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials" by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and used to determine the repeatability and the reproducibility (expressed as standard deviations) of both methods. The calculation was carried out according to the related standard. The results are specified and discussed in this paper, as are the optimized analytical conditions determined and used by the authors of this paper. For both methods, the repeatability relative standard deviations were <25%, usually ~10%, and the reproducibility relative standard deviations were <35%, usually ~15%. These results were regarded as satifactory for both methods intended for rapid analysis of materials for which decomposition is difficult and time-consuming. Also described are some results from an interlaboratory comparison used to certify one of the materials that had been previously used for validation in both interlaboratory comparisons. Thirty laboratories (from eight countries) participated in this interlaboratory comparison for certification. As examples, accepted results are shown from laboratories that used ETV ICP OES or DC arc OES and had performed calibrations by using solutions or oxides, respectively. The certified mass fractions of the certified reference materials were also compared with the mass fractions determined in the interlaboratory comparisons performed within the framework of method standardization. Good agreement was found for most of the analytes.
Rakita, Slađana; Pojić, Milica; Tomić, Jelena; Torbica, Aleksandra
2014-05-01
The aim of the present study was to determine the characteristics of an analytical method for determination of free sulphydryl (SH) groups of wheat gluten performed with previous gluten incubation for variable times (45, 90 and 135min) at variable temperatures (30 and 37°C), in order to determine its fitness-for-purpose. It was observed that the increase in temperature and gluten incubation time caused the increase in the amount of free SH groups, with more dynamic changes at 37°C. The method characteristics identified as relevant were: linearity, limit of detection, limit of quantification, precision (repeatability and reproducibility) and measurement uncertainty, which were checked within the validation protocol, while the method performance was monitored by X- and R-control charts. Identified method characteristics demonstrated its acceptable fitness-for-purpose, when assay included previous gluten incubation at 30°C. Although the method repeatability at 37°C was acceptable, the corresponding reproducibility did not meet the performance criterion on the basis of HORRAT value (HORRAT<2). Copyright © 2013 Elsevier Ltd. All rights reserved.
Toward a Digital Thread and Data Package for Metals-Additive Manufacturing.
Kim, D B; Witherell, P; Lu, Y; Feng, S
2017-01-01
Additive manufacturing (AM) has been envisioned by many as a driving factor of the next industrial revolution. Potential benefits of AM adoption include the production of low-volume, customized, complicated parts/products, supply chain efficiencies, shortened time-to-market, and environmental sustainability. Work remains, however, for AM to reach the status of a full production-ready technology. Whereas the ability to create unique 3D geometries has been generally proven, production challenges remain, including lack of (1) data manageability through information management systems, (2) traceability to promote product producibility, process repeatability, and part-to-part reproducibility, and (3) accountability through mature certification and qualification methodologies. To address these challenges in part, this paper discusses the building of data models to support the development of validation and conformance methodologies in AM. We present an AM information map that leverages informatics to facilitate part producibility, process repeatability, and part-to-part reproducibility in an AM process. We present three separate case studies to demonstrate the importance of establishing baseline data structures and part provenance through an AM digital thread.
Toward a Digital Thread and Data Package for Metals-Additive Manufacturing
Kim, D. B.; Witherell, P.; Lu, Y.; Feng, S.
2017-01-01
Additive manufacturing (AM) has been envisioned by many as a driving factor of the next industrial revolution. Potential benefits of AM adoption include the production of low-volume, customized, complicated parts/products, supply chain efficiencies, shortened time-to-market, and environmental sustainability. Work remains, however, for AM to reach the status of a full production-ready technology. Whereas the ability to create unique 3D geometries has been generally proven, production challenges remain, including lack of (1) data manageability through information management systems, (2) traceability to promote product producibility, process repeatability, and part-to-part reproducibility, and (3) accountability through mature certification and qualification methodologies. To address these challenges in part, this paper discusses the building of data models to support the development of validation and conformance methodologies in AM. We present an AM information map that leverages informatics to facilitate part producibility, process repeatability, and part-to-part reproducibility in an AM process. We present three separate case studies to demonstrate the importance of establishing baseline data structures and part provenance through an AM digital thread. PMID:28691115
Mrčela, I; Bokulić, T; Izewska, J; Budanec, M; Fröbe, A; Kusić, Z
2011-09-21
A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in repeated irradiations of the same dosimeters it was found to be 3.5%. When OSL dosimeters were optically bleached between exposures, the reproducibility of repeated measurements improved to 1.0%. Dosimeters were calibrated for the entrance dose measurements and a full set of correction factors was determined. A pilot patient study that followed phantom validation testing included more than 100 measured fields with a mean relative difference of the measured entrance dose from the expected dose of 0.8% and the standard deviation of 2.5%. In conclusion, these results demonstrate that OSL dot dosimeters represent a valid alternative to already established in vivo dosimetry systems.
NASA Astrophysics Data System (ADS)
Mrčela, I.; Bokulić, T.; Izewska, J.; Budanec, M.; Fröbe, A.; Kusić, Z.
2011-09-01
A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in 60Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in repeated irradiations of the same dosimeters it was found to be 3.5%. When OSL dosimeters were optically bleached between exposures, the reproducibility of repeated measurements improved to 1.0%. Dosimeters were calibrated for the entrance dose measurements and a full set of correction factors was determined. A pilot patient study that followed phantom validation testing included more than 100 measured fields with a mean relative difference of the measured entrance dose from the expected dose of 0.8% and the standard deviation of 2.5%. In conclusion, these results demonstrate that OSL dot dosimeters represent a valid alternative to already established in vivo dosimetry systems.
Bailes, Helena J; Zhuang, Ling-Yu; Lucas, Robert J
2012-01-01
Originally developed to regulate neuronal excitability, optogenetics is increasingly also used to control other cellular processes with unprecedented spatiotemporal resolution. Optogenetic modulation of all major G-protein signalling pathways (Gq, Gi and Gs) has been achieved using variants of mammalian rod opsin. We show here that the light response driven by such rod opsin-based tools dissipates under repeated exposure, consistent with the known bleaching characteristics of this photopigment. We continue to show that replacing rod opsin with a bleach resistant opsin from Carybdea rastonii, the box jellyfish, (JellyOp) overcomes this limitation. Visible light induced high amplitude, reversible, and reproducible increases in cAMP in mammalian cells expressing JellyOp. While single flashes produced a brief cAMP spike, repeated stimulation could sustain elevated levels for 10s of minutes. JellyOp was more photosensitive than currently available optogenetic tools, responding to white light at irradiances ≥1 µW/cm(2). We conclude that JellyOp is a promising new tool for mimicking the activity of Gs-coupled G protein coupled receptors with fine spatiotemporal resolution.
Validation of the Filovirus Plaque Assay for Use in Preclinical Studies
Shurtleff, Amy C.; Bloomfield, Holly A.; Mort, Shannon; Orr, Steven A.; Audet, Brian; Whitaker, Thomas; Richards, Michelle J.; Bavari, Sina
2016-01-01
A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4) studies. After standardization studies were completed, Good Laboratory Practices (GLP)-compliant plaque assay method validation studies to demonstrate suitability for reliable and reproducible measurement of the Marburg Virus Angola (MARV) variant and Ebola Virus Kikwit (EBOV) variant commenced at the United States Army Medical Research Institute of Infectious Diseases (USAMRIID). The validation parameters tested included accuracy, precision, linearity, robustness, stability of the virus stocks and system suitability. The MARV and EBOV assays were confirmed to be accurate to ±0.5 log10 PFU/mL. Repeatability precision, intermediate precision and reproducibility precision were sufficient to return viral titers with a coefficient of variation (%CV) of ≤30%, deemed acceptable variation for a cell-based bioassay. Intraclass correlation statistical techniques for the evaluation of the assay’s precision when the same plaques were quantitated by two analysts returned values passing the acceptance criteria, indicating high agreement between analysts. The assay was shown to be accurate and specific when run on Nonhuman Primates (NHP) serum and plasma samples diluted in plaque assay medium, with negligible matrix effects. Virus stocks demonstrated stability for freeze-thaw cycles typical of normal usage during assay retests. The results demonstrated that the EBOV and MARV plaque assays are accurate, precise and robust for filovirus titration in samples associated with the performance of GLP animal model studies. PMID:27110807
Zhou, Joseph Ziqi; Waszkuc, Ted; Mohammed, Felicia
2008-01-01
A collaborative study was conducted for determination of glucosamine in raw materials and dietary supplements containing glucosamine sulfate and/or glucosamine hydrochloride by high-performance liquid Chromatography (HPLC) with N-(9-fluorenyl-methoxycarbonyloxy) succinimide (FMOC-Su) derivatization. Thirteen blind materials, one pair of which were duplicates, were tested by 12 collaborating laboratories. The test samples consisted of various commercial products, including tablets, capsules, drink mix, and liquids as well as raw materials, blanks, and those for spike recovery analyses. The tests with blank products and products spiked with glucosamine showed good specificity of the method. The average recoveries at spike levels of 100 and 150% of the declared amount were 99.0% with a relative standard deviation (RSD) of 2.1%, and 101% with an RSD of 2.3%, respectively. The test results between laboratories on each commercial product were reproducible with RSD values of no more than 4.0%, and the results were repeatable in the same laboratory with an average RSD of 0.7%. HorRat values ranged from 0.5 to 1.7 on both tests of spike recovery and reproducibility between laboratories on commercial products. The average determination coefficient of the calibration curves from the laboratories was 0.9995 with an RSD of 0.03%. All of the 12 collaborating laboratories succeeded in the study and none of their reported test results were outliers, partly indicating the robustness of the method. It is recommended that the method be accepted by AOAC INTERNATIONAL as Official First Action. PMID:16152919
Bianchini, Elisabetta; Bozec, Erwan; Gemignani, Vincenzo; Faita, Francesco; Giannarelli, Chiara; Ghiadoni, Lorenzo; Demi, Marcello; Boutouyrie, Pierre; Laurent, Stéphane
2010-08-01
Increased arterial stiffness and carotid intima-media thickness (IMT) are considered independent predictors of cardiovascular events. The aim of this study was to compare a system recently developed in our laboratory for automatic assessment of these parameters from ultrasound image sequences to a reference radio frequency (RF) echo-tracking system. Common carotid artery scans of 21 patients with cardiovascular risk factors and 12 healthy volunteers were analyzed by both devices for the assessment of diameter (D), IMT, and distension (DeltaD). In the healthy volunteers, analyses were repeated twice to evaluate intraobserver variability. Agreement was evaluated by Bland-Altman analysis, whereas reproducibility was expressed as a coefficient of variation (CV). Regarding the agreement between the two systems, bias values +/- SD were 0.060 +/- 0.110 mm for D, -0.006 +/- 0.039 mm for IMT, and -0.016 +/- 0.039 mm for DeltaD. Intraobserver CVs were 2% +/- 2% for D, 5% +/- 5% for IMT, and 6% +/- 6% for DeltaD with the RF echo-tracking system and 2% +/- 1% for D, 6% +/- 6% for IMT, and 8% +/- 6% for DeltaD with our automated system. Although B-mode-based devices are less precise than RF-based ones, our automated system has good agreement with the reference method and comparable reproducibility, at least when high-quality images are analyzed. Hence, this study suggests that the presented system based on image processing from standard ultrasound scans is a suitable device for measuring IMT and local arterial stiffness parameters in clinical studies.
De Angelis C; Fattibene; Onori; Petetti; Bartolotta; Sansone Santamaria A
2000-05-01
Alanine-polyethylene solid state dosimeters were prepared at Istituto Superiore di Sanita (ISS) following the recipe proposed by National Institute of Standards and Technology (NIST) with the goal of testing its transferability. Dosimeters were prepared using 95% alanine and 5% polyethylene, by weight. They are rugged and of increased sensitivity, repeatability and reproducibility as respect to the ISS alanine-paraffin pellets. Reproducibility of about 1% was obtained at 10 Gy and at 3 Gy if one single pellet or a stack of five dosimeters were used, respectively.
Gross, S; Janssen, S W J; de Vries, B; Terao, E; Daas, A; Buchheit, K-H
2009-10-01
The European Pharmacopoeia (Ph. Eur.) monograph Human tetanus immunoglobulin (0398) gives a clear outline of the in vivo assay to be performed to determine the potency of human tetanus immunoglobulins during their development. Furthermore, it states that an in vitro method shall be validated for the batch potency estimation. Since no further guidance is given on the in vitro assay, every control laboratory concerned is free to design and validate an in-house method. At the moment there is no agreed in vitro method available. The aim of this study was to validate and compare 2 alternative in vitro assays, i.e. an enzyme-linked immunoassay (EIA) and a toxoid inhibition assay (TIA), through an international collaborative study, in view of their eventual inclusion into the Ph. Eur.. The study was run in the framework of the Biological Standardisation Programme (BSP), under the aegis of the European Commission and the Council of Europe. The collaborative study reported here involved 21 laboratories (public and industry) from 15 countries. Initially, 3 samples with low, medium and high potencies were tested by EIA and TIA. Results showed good reproducibility and repeatability of the 2 in vitro methods. The correlation of the data with the in vivo potency assigned by the manufacturers however appeared initially poor for high potency samples. Thorough re-examination of the data showed that the in vivo potencies assigned by the manufacturers had to be corrected: one for potency loss at the time of in vitro testing and one because of a reporting error. After these corrections the values obtained by in vivo and in vitro methods were in close agreement. A supplementary collaborative work was carried out to validate the 2 methods for immunoglobulin products with high potencies. Eight laboratories (public and industry) took part in this additional study to test 3 samples with medium and high potencies by EIA and TIA. Results confirmed that the 2 alternative methods are comparable in terms of assay repeatability, precision and reproducibility. In all laboratories, both methods discriminated between the low, medium and high potency samples. Analysis of the data collected in this study showed a good correlation between EIA and TIA potency estimates as well as a close agreement between values obtained by in vitro and in vivo methods. The study demonstrated that EIA and TIA are suitable quality control methods for polyclonal human tetanus immunoglobulin, which can be standardised in a quality control laboratory using a quality assurance system. Consequently, the Ph. Eur. Group of Experts 6B on Human Blood and Blood products decided in April 2009 to include both methods as examples in the Ph. Eur. monograph 0398 on Human Tetanus immunoglobulin.
Adaptive play stabilizes cooperation in continuous public goods games
NASA Astrophysics Data System (ADS)
Wu, Te; Wang, Long
2018-04-01
We construct a model to study the effects of repeated interaction on the evolution of cooperation in continuous public goods games. Instead of preassigning the duration of repeatedness, the likelihood of group entering next round interaction is positively dependent on the group's current cooperativeness. Meanwhile, when the disturbance happens, the interaction terminates. Under rare mutations, we show that such adaptive play can lead to the dominance of full cooperative state for weak disturbance. For fairly strong disturbance, all-or-none cooperative states share higher fractions of time in the long run, results similar to the ones reported in the study (Pinheiro et al., 2014) while differing from the ones reported in another relevant study (Van Segbroeck et al., 2012), although only strategy space and way determining next round vary. Our results remain valid when groups enter next round with a given probability independent of groups' cooperativeness. In the synergic public goods games, the positive effects of repeated interactions on promoting cooperation is further strengthened. In the discounted public goods game, only very weak disturbance can lead to the dominance of full cooperative state while fairly strong disturbance can favor both full cooperative state and a partially cooperative state. Our study thus enriches the literature on the evolution of cooperation in repeated public goods games.
Enhancing reproducibility of SALDI MS detection by concentrating analytes within laser spot.
Teng, Fei; Zhu, Qunyan; Wang, Yalei; Du, Juan; Lu, Nan
2018-03-01
Surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI TOF MS) has become one of the most important analytical methods due to its less interference at low molecular weight range. However, it is still a challenge to obtain a good reproducibility of SALDI TOF MS because of the inhomogeneous distribution of analyte molecules induced by coffee ring effect. We propose a universal and reliable method to eliminate the coffee ring effect by concentrating all the analyte molecules within the laser spot. This method exhibits an excellent reproducibility of spot-to-spot and substrate-to-substrate, and the relative standard deviations (RSDs) for different concentrations are lower than 12.6%. It also performs good linear dependency (R 2 > 0.98) in the log-log plot with the concentration range of 1nM to 1μM, and the limit of detection for R6G is down to 1fmol. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tessier, Francois; Vishwanath, Venkatram
2017-11-28
Reading and writing data efficiently from different tiers of storage is necessary for most scientific simulations to achieve good performance at scale. Many software solutions have been developed to decrease the I/O bottleneck. One wellknown strategy, in the context of collective I/O operations, is the two-phase I/O scheme. This strategy consists of selecting a subset of processes to aggregate contiguous pieces of data before performing reads/writes. In our previous work, we implemented the two-phase I/O scheme with a MPI-based topology-aware algorithm. Our algorithm showed very good performance at scale compared to the standard I/O libraries such as POSIX I/O andmore » MPI I/O. However, the algorithm had several limitations hindering a satisfying reproducibility of our experiments. In this paper, we extend our work by 1) identifying the obstacles we face to reproduce our experiments and 2) discovering solutions that reduce the unpredictability of our results.« less
Jung, Soyeon; Chin, Hee Seung; Kim, Na Rae; Lee, Kang Won; Jung, Ji Won
2017-01-01
To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT ( P > 0.050), although flattest K, mean K, and CCT differed ( P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.
Wu, Lingxia; Lu, Xianbo; Dhanjai; Wu, Zhong-Shuai; Dong, Yanfeng; Wang, Xiaohui; Zheng, Shuanghao; Chen, Jiping
2018-06-01
MXene-Ti 3 C 2 , as a new class of two-dimensional (2D) transition metal carbides (or nitrides), has been synthesized by exfoliating pristine Ti 3 AlC 2 phases with hydrofluoric acid. The SEM and XRD images show that the resultant MXene possesses a graphene-like 2D nanostructure. and the surface of MXene has been partially terminated with -OH, thus providing a favorable microenvironment for enzyme immobilization and retaining their bioactivity and stability. Considering the unique metallic conductivity, biocompatibility and good dispersion in aqueous phase, the as-prepared MXene was explored as a new matrix to immobilize tyrosinase (a model enzyme) for fabricating a mediator-free biosensor for ultrasensitive and rapid detection of phenol. The varying electrochemical measurements were used to investigate the electrochemical performance of MXene-based tyrosinase biosensors. The results revealed that the direct electron transfer between tyrosinase and electrode could be easily achieved via a surface-controlled electrochemical process. The fabricated MXene-based tyrosinase biosensors exhibited good analytical performance over a wide linear range from 0.05 to 15.5 μmol L -1 , with a low detection limit of 12 nmol L -1 and a sensitivity of 414.4 mA M -1 . The proposed biosensing approach also demonstrated good repeatability, reproducibility, long-term stability and high recovery for phenol detection in real water samples. With those excellent performances, MXene with graphene-like structure is proved to be a robust and versatile electrochemical biosensing platform for enzyme-based biosensors and biocatalysis, and has wide potential applications in biomedical detection and environmental analysis. Copyright © 2018. Published by Elsevier B.V.
Amanzadeh, Hatam; Yamini, Yadollah; Moradi, Morteza; Asl, Yousef Abdossalmi
2016-09-23
In the current study, a graphene/polyvinylchloride nanocomposite was successfully coated on a stainless steel substrate by a simple dip coating process and used as a novel headspace solid phase microextraction (HS-SPME) fiber for the extraction of phthalate esters (PEs) from drinking water and edible vegetable oil samples. The prepared SPME fibers exhibited high extractability for PEs (due to the dominant role of π-π stacking interactions and hydrophobic effects) yielding good sensitivity and precision when followed by a gas chromatograph with a flame ionization detector (GC-FID). The optimization strategy of the extraction process was carried out using the response surface method based on a central composite design. The developed method gave a low limit of detection (0.06-0.08μgL(-1)) and good linearity (0.2-100μgL(-1)) for the determination of the PEs under the optimized conditions (extraction temperature, 70±1°C; extraction time, 35min; salt concentration, 30% w/v; stirring rate, 900rpm; desorption temperature, 230°C; and desorption time, 4min) whereas the repeatability and fiber-to-fiber reproducibility were in the range 6.1-7.8% and 8.9-10.2%, respectively. Finally, the proposed method was successfully applied to the analysis of PEs in drinking water and edible oil samples with good recoveries (87-112%) and satisfactory precisions (RSDs<8.3%), indicating the absence of matrix effects in the proposed HS-SPME method. Copyright © 2016 Elsevier B.V. All rights reserved.
Gumpu, Manju Bhargavi; Krishnan, Uma Maheswari; Rayappan, John Bosco Balaguru
2017-07-01
Intake of water contaminated with lead (Pb 2+ ) and mercury (Hg 2+ ) ions leads to various toxic effects and health issues. In this context, an amperometric urease inhibition-based biosensor was developed to detect Pb 2+ and Hg 2+ ions in water matrix. The modified Pt/CeO 2 /urease electrode was fabricated by immobilizing CeO 2 nanoparticles and urease using a semi-permeable adsorption layer of nafion. With urea as a substrate, urease catalytic activity was examined through cyclic voltammetry. Further, maximum amperometric inhibitive response of the modified Pt/CeO 2 /urease electrode was observed in the presence of Pb 2+ and Hg 2+ ions due to the urease inhibition at specific potentials of -0.03 and 0 V, respectively. The developed sensor exhibited a detection limit of 0.019 ± 0.001 μM with a sensitivity of 89.2 × 10 -3 μA μM -1 for Pb 2+ ions. A detection limit of 0.018 ± 0.003 with a sensitivity of 94.1 × 10 -3 μA μM -1 was achieved in detecting Hg 2+ ions. The developed biosensor showed a fast response time (<1 s) with a linear range of 0.5-2.2 and 0.02-0.8 μM for Pb 2+ and Hg 2+ ions, respectively. The modified electrode offered a good stability for 20 days with a good repeatability and reproducibility. The developed sensor was used to detect Pb 2+ and Hg 2+ ions contaminating Cauvery river water and the observed results were in good co-ordination with atomic absorption spectroscopic data.
Ibupoto, Z H; Khun, K; Liu, X; Willander, M
2013-10-01
In this study, we have successfully synthesised CuO bundle of nanowires using simple, cheap and low temperature hydrothermal growth method. The growth parameters such as precursor concentration and time for duration of growth were optimised. The field emission scanning electron microscopy (FESEM) has demonstrated that the CuO bundles of nanowires are highly dense, uniform and perpendicularly oriented to the substrate. The high resolution transmission electron microscopy (HRTEM) has demonstrated that the CuO nanostructures consist of bundle of nanowires and their growth pattern is along the [010] direction. The X-ray diffraction (XRD) technique described that CuO bundle of nanowires possess the monoclinic crystal phase. The surface and chemical composition analyses were carried out with X-ray photoelectron spectroscopy (XPS) technique and the obtained results suggested the pure crystal state of CuO nanostructures. In addition, the CuO nanowires were used for the cholesterol sensing application by immobilising the cholesterol oxidase through electrostatic attraction. The infrared reflection absorption spectroscopy study has also revealed that CuO nanostructures are consisting of only CuO bonding and has also shown the possible interaction of cholesterol oxidase with the sharp edge surface of CuO bundle of nanowires. The proposed cholesterol sensor has demonstrated the wide range of detection of cholesterol with good sensitivity of 33.88±0.96 mV/decade. Moreover, the CuO bundle of nanowires based sensor electrode has revealed good repeatability, reproducibility, stability, selectivity and a fast response time of less than 10s. The cholesterol sensor based on the immobilised cholesterol oxidase has good potential applicability for the determination of cholesterol from the human serum and other biological samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Color reproduction for advanced manufacture of soft tissue prostheses.
Xiao, Kaida; Zardawi, Faraedon; van Noort, Richard; Yates, Julian M
2013-11-01
The objectives of this study were to develop a color reproduction system in advanced manufacture technology for accurate and automatic processing of soft tissue prostheses. The manufacturing protocol was defined to effectively and consistently produce soft tissue prostheses using a 3D printing system. Within this protocol printer color profiles were developed using a number of mathematical models for the proposed 3D color printing system based on 240 training colors. On this basis, the color reproduction system was established and their system errors including accuracy of color reproduction, performance of color repeatability and color gamut were evaluated using 14 known human skin shades. The printer color profile developed using the third-order polynomial regression based on least-square fitting provided the best model performance. The results demonstrated that by using the proposed color reproduction system, 14 different skin colors could be reproduced and excellent color reproduction performance achieved. Evaluation of the system's color repeatability revealed a demonstrable system error and this highlighted the need for regular evaluation. The color gamut for the proposed 3D printing system was simulated and it was demonstrated that the vast majority of skin colors can be reproduced with the exception of extreme dark or light skin color shades. This study demonstrated that the proposed color reproduction system can be effectively used to reproduce a range of human skin colors for application in advanced manufacture of soft tissue prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
World survey of mental illness stigma.
Seeman, Neil; Tang, Sabrina; Brown, Adalsteinn D; Ing, Alton
2016-01-15
To obtain rapid and reproducible opinions that address mental illness stigma around the world. Random global Web users were exposed to brief questions, asking whether they interacted daily with someone with mental illness, whether they believed that mental illness was associated with violence, whether it was similar to physical illness, and whether it could be overcome. Over a period of 1.7 years, 596,712 respondents from 229 countries completed the online survey. The response rate was 54.3%. China had the highest proportion of respondents in daily contact with a person with mental illness. In developed countries, 7% to 8% of respondents endorsed the statement that individuals with mental illness were more violent than others, in contrast to 15% or 16% in developing countries. While 45% to 51% of respondents from developed countries believed that mental illness was similar to physical illness, only 7% believed that mental illness could be overcome. To test for reproducibility, 21 repeats of the same questions were asked monthly in India for 21 months. Each time, 10.1 ± 0.11% s.e., of respondents endorsed the statement that persons who suffer from mental illness are more violent than others, indicating strong reproducibility of response. This study shows that surveys of constructs such as stigma towards mental illness can be carried out rapidly and repeatedly across the globe, so that the impact of policy interventions can be readily measured. The method engages English speakers only, mainly young, educated males. Copyright © 2015 Elsevier B.V. All rights reserved.
Lu, Kun-Han; Hung, Shao-Chin; Wen, Haiguang; Marussich, Lauren; Liu, Zhongming
2016-01-01
Complex, sustained, dynamic, and naturalistic visual stimulation can evoke distributed brain activities that are highly reproducible within and across individuals. However, the precise origins of such reproducible responses remain incompletely understood. Here, we employed concurrent functional magnetic resonance imaging (fMRI) and eye tracking to investigate the experimental and behavioral factors that influence fMRI activity and its intra- and inter-subject reproducibility during repeated movie stimuli. We found that widely distributed and highly reproducible fMRI responses were attributed primarily to the high-level natural content in the movie. In the absence of such natural content, low-level visual features alone in a spatiotemporally scrambled control stimulus evoked significantly reduced degree and extent of reproducible responses, which were mostly confined to the primary visual cortex (V1). We also found that the varying gaze behavior affected the cortical response at the peripheral part of V1 and in the oculomotor network, with minor effects on the response reproducibility over the extrastriate visual areas. Lastly, scene transitions in the movie stimulus due to film editing partly caused the reproducible fMRI responses at widespread cortical areas, especially along the ventral visual pathway. Therefore, the naturalistic nature of a movie stimulus is necessary for driving highly reliable visual activations. In a movie-stimulation paradigm, scene transitions and individuals’ gaze behavior should be taken as potential confounding factors in order to properly interpret cortical activity that supports natural vision. PMID:27564573
Slide Set: Reproducible image analysis and batch processing with ImageJ.
Nanes, Benjamin A
2015-11-01
Most imaging studies in the biological sciences rely on analyses that are relatively simple. However, manual repetition of analysis tasks across multiple regions in many images can complicate even the simplest analysis, making record keeping difficult, increasing the potential for error, and limiting reproducibility. While fully automated solutions are necessary for very large data sets, they are sometimes impractical for the small- and medium-sized data sets common in biology. Here we present the Slide Set plugin for ImageJ, which provides a framework for reproducible image analysis and batch processing. Slide Set organizes data into tables, associating image files with regions of interest and other relevant information. Analysis commands are automatically repeated over each image in the data set, and multiple commands can be chained together for more complex analysis tasks. All analysis parameters are saved, ensuring transparency and reproducibility. Slide Set includes a variety of built-in analysis commands and can be easily extended to automate other ImageJ plugins, reducing the manual repetition of image analysis without the set-up effort or programming expertise required for a fully automated solution.
Can cancer researchers accurately judge whether preclinical reports will reproduce?
Mandel, David R.; Kimmelman, Jonathan
2017-01-01
There is vigorous debate about the reproducibility of research findings in cancer biology. Whether scientists can accurately assess which experiments will reproduce original findings is important to determining the pace at which science self-corrects. We collected forecasts from basic and preclinical cancer researchers on the first 6 replication studies conducted by the Reproducibility Project: Cancer Biology (RP:CB) to assess the accuracy of expert judgments on specific replication outcomes. On average, researchers forecasted a 75% probability of replicating the statistical significance and a 50% probability of replicating the effect size, yet none of these studies successfully replicated on either criterion (for the 5 studies with results reported). Accuracy was related to expertise: experts with higher h-indices were more accurate, whereas experts with more topic-specific expertise were less accurate. Our findings suggest that experts, especially those with specialized knowledge, were overconfident about the RP:CB replicating individual experiments within published reports; researcher optimism likely reflects a combination of overestimating the validity of original studies and underestimating the difficulties of repeating their methodologies. PMID:28662052
DNA-directed mutations. Leading and lagging strand specificity
NASA Technical Reports Server (NTRS)
Sinden, R. R.; Hashem, V. I.; Rosche, W. A.
1999-01-01
The fidelity of replication has evolved to reproduce B-form DNA accurately, while allowing a low frequency of mutation. The fidelity of replication can be compromised, however, by defined order sequence DNA (dosDNA) that can adopt unusual or non B-DNA conformations. These alternative DNA conformations, including hairpins, cruciforms, triplex DNAs, and slipped-strand structures, may affect enzyme-template interactions that potentially lead to mutations. To analyze the effect of dosDNA elements on spontaneous mutagenesis, various mutational inserts containing inverted repeats or direct repeats were cloned in a plasmid containing a unidirectional origin of replication and a selectable marker for the mutation. This system allows for analysis of mutational events that are specific for the leading or lagging strands during DNA replication in Escherichia coli. Deletions between direct repeats, involving misalignment stabilized by DNA secondary structure, occurred preferentially on the lagging strand. Intermolecular strand switch events, correcting quasipalindromes to perfect inverted repeats, occurred preferentially during replication of the leading strand.
WAVE3 is a Biomarker for Breast Cancer Progression and Metastasis
2012-04-01
insure reproducibility of the results. f) Repeat tasks a to e for the specimens with questionable results. Completed. See below Task 7: A BC TMA...miRs 570, 542, 103, 107 and 302, all of which have been found to be deregulated during cancer progression and metastasis [26,33,39–44], therefore
40 CFR 63.786 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... level of sample dilution must be factored in. (2) Repeatability. First, at the 0.1-5 percent analyte... percent analyte range the results would be suspect if duplicates vary by more than 5 percent relative and...) Reproducibility. First, at the 0.1-5 percent analyte range the results would be suspect if lab to lab variation...
40 CFR 63.786 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... level of sample dilution must be factored in. (2) Repeatability. First, at the 0.1-5 percent analyte... percent analyte range the results would be suspect if duplicates vary by more than 5 percent relative and...) Reproducibility. First, at the 0.1-5 percent analyte range the results would be suspect if lab to lab variation...
Dengel, Donald R; Evanoff, Nicholas G; Marlatt, Kara L; Geijer, Justin R; Mueller, Bryon A; Lim, Kelvin O
2017-11-01
Hypercapnia has been utilized as a stimulus to elicit changes in cerebral blood flow (CBF). However, in many instances it has been delivered in a non-controlled method that is often difficult to reproduce. The purpose of this study was to examine the within- and between-visit reproducibility of blood oxygen level-dependent (BOLD) signal changes to an iso-oxic square wave alteration in end-tidal carbon dioxide partial pressure (P et CO 2 ). Two 3-Tesla (3T) MRI scans were performed on the same visit, with two square wave alterations administered per scan. The protocol was repeated on a separate visit with minimum of 3 days between scanning sessions. P et CO 2 was altered to stimulate changes in cerebral vascular reactivity (CVR), while P et O 2 was held constant. Eleven subjects (six females; mean age 26·5 ± 5·7 years) completed the full testing protocol. Excellent within-visit square wave reproducibility (ICC > 0·75) was observed. Similarly, square waves were reproducible between scanning sessions (ICC > 0·7). This study demonstrates BOLD signal changes in response to alterations in P et CO 2 are reproducible both within- and between-visit MRI scans. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Reproducibility measurements of three methods for calculating in vivo MR-based knee kinematics.
Lansdown, Drew A; Zaid, Musa; Pedoia, Valentina; Subburaj, Karupppasamy; Souza, Richard; Benjamin, C; Li, Xiaojuan
2015-08-01
To describe three quantification methods for magnetic resonance imaging (MRI)-based knee kinematic evaluation and to report on the reproducibility of these algorithms. T2 -weighted, fast-spin echo images were obtained of the bilateral knees in six healthy volunteers. Scans were repeated for each knee after repositioning to evaluate protocol reproducibility. Semiautomatic segmentation defined regions of interest for the tibia and femur. The posterior femoral condyles and diaphyseal axes were defined using the previously defined tibia and femur. All segmentation was performed twice to evaluate segmentation reliability. Anterior tibial translation (ATT) and internal tibial rotation (ITR) were calculated using three methods: a tibial-based registration system, a combined tibiofemoral-based registration method with all manual segmentation, and a combined tibiofemoral-based registration method with automatic definition of condyles and axes. Intraclass correlation coefficients and standard deviations across multiple measures were determined. Reproducibility of segmentation was excellent (ATT = 0.98; ITR = 0.99) for both combined methods. ATT and ITR measurements were also reproducible across multiple scans in the combined registration measurements with manual (ATT = 0.94; ITR = 0.94) or automatic (ATT = 0.95; ITR = 0.94) condyles and axes. The combined tibiofemoral registration with automatic definition of the posterior femoral condyle and diaphyseal axes allows for improved knee kinematics quantification with excellent in vivo reproducibility. © 2014 Wiley Periodicals, Inc.
Hackley, Paul C.; Araujo, Carla Viviane; Borrego, Angeles G.; Bouzinos, Antonis; Cardott, Brian; Cook, Alan C.; Eble, Cortland; Flores, Deolinda; Gentzis, Thomas; Gonçalves, Paula Alexandra; Filho, João Graciano Mendonça; Hámor-Vidó, Mária; Jelonek, Iwona; Kommeren, Kees; Knowles, Wayne; Kus, Jolanta; Mastalerz, Maria; Menezes, Taíssa Rêgo; Newman, Jane; Pawlewicz, Mark; Pickel, Walter; Potter, Judith; Ranasinghe, Paddy; Read, Harold; Reyes, Julito; Rodriguez, Genaro De La Rosa; de Souza, Igor Viegas Alves Fernandes; Suarez-Ruiz, Isabel; Sýkorová, Ivana; Valentine, Brett J.
2015-01-01
Vitrinite reflectance generally is considered the most robust thermal maturity parameter available for application to hydrocarbon exploration and petroleum system evaluation. However, until 2011 there was no standardized methodology available to provide guidelines for vitrinite reflectance measurements in shale. Efforts to correct this deficiency resulted in publication of ASTM D7708: Standard test method for microscopical determination of the reflectance of vitrinite dispersed in sedimentary rocks. In 2012-2013, an interlaboratory exercise was conducted to establish precision limits for the D7708 measurement technique. Six samples, representing a wide variety of shale, were tested in duplicate by 28 analysts in 22 laboratories from 14 countries. Samples ranged from immature to overmature (0.31-1.53% Ro), from organic-lean to organic-rich (1-22 wt.% total organic carbon), and contained Type I (lacustrine), Type II (marine), and Type III (terrestrial) kerogens. Repeatability limits (maximum difference between valid repetitive results from same operator, same conditions) ranged from 0.03-0.11% absolute reflectance, whereas reproducibility limits (maximum difference between valid results obtained on same test material by different operators, different laboratories) ranged from 0.12-0.54% absolute reflectance. Repeatability and reproducibility limits degraded consistently with increasing maturity and decreasing organic content. However, samples with terrestrial kerogens (Type III) fell off this trend, showing improved levels of reproducibility due to higher vitrinite content and improved ease of identification. Operators did not consistently meet the reporting requirements of the test method, indicating that a common reporting template is required to improve data quality. The most difficult problem encountered was the petrographic distinction of solid bitumens and low-reflecting inert macerals from vitrinite when vitrinite occurred with reflectance ranges overlapping the other components. Discussion among participants suggested this problem could not be easily corrected via kerogen concentration or solvent extraction and is related to operator training and background. No statistical difference in mean reflectance was identified between participants reporting bitumen reflectance vs. vitrinite reflectance vs. a mixture of bitumen and vitrinite reflectance values, suggesting empirical conversion schemes should be treated with caution. Analysis of reproducibility limits obtained during this exercise in comparison to reproducibility limits from historical interlaboratory exercises suggests use of a common methodology (D7708) improves interlaboratory precision. Future work will investigate opportunities to improve reproducibility in high maturity, organic-lean shale varieties.
spa typing for epidemiological surveillance of Staphylococcus aureus.
Hallin, Marie; Friedrich, Alexander W; Struelens, Marc J
2009-01-01
The spa typing method is based on sequencing of the polymorphic X region of the protein A gene (spa), present in all strains of Staphylococcus aureus. The X region is constituted of a variable number of 24-bp repeats flanked by well-conserved regions. This single-locus sequence-based typing method combines a number of technical advantages, such as rapidity, reproducibility, and portability. Moreover, due to its repeat structure, the spa locus simultaneously indexes micro- and macrovariations, enabling the use of spa typing in both local and global epidemiological studies. These studies are facilitated by the establishment of standardized spa type nomenclature and Internet shared databases.
Prince, Linda M
2015-01-01
Inter-simple sequence repeat PCR (ISSR-PCR) is a fast, inexpensive genotyping technique based on length variation in the regions between microsatellites. The method requires no species-specific prior knowledge of microsatellite location or composition. Very small amounts of DNA are required, making this method ideal for organisms of conservation concern, or where the quantity of DNA is extremely limited due to organism size. ISSR-PCR can be highly reproducible but requires careful attention to detail. Optimization of DNA extraction, fragment amplification, and normalization of fragment peak heights during fluorescent detection are critical steps to minimizing the downstream time spent verifying and scoring the data.
Reproducibility of a four-point clinical severity score for glabellar frown lines.
Honeck, P; Weiss, C; Sterry, W; Rzany, B
2003-08-01
Focal injections of botulinum toxin A are used successfully for the treatment of hyperkinetic facial wrinkles. Efficacy can be measured by several methods. However, so far none has been investigated for its reproducibility. Objectives To investigate the reproducibility of a clinical 0-3 score for glabellar frown lines. In the first part of the study, a standardized photographic documentation of glabellar frown lines was produced. Based on the results of this phase, a consensus atlas of glabellar frown lines was developed and participants were trained using this atlas. In the main study, 50 standardized photographs were shown on two consecutive days to 28 dermatologists. The reproducibility of the score was investigated by conventional kappa statistics. In the main study, we found an unweighted kappa according to Fleiss of 0.62 for interobserver reproducibility. Intraobserver reproducibility showed an unweighted kappa according to Cohen of between 0.57 and 0.91 for each observer, and a weighted kappa according to Cicchetti and Allison of between 0.68 and 0.94. The clinical 0-3 score for glabellar frown lines shows a good inter- and intraobserver reproducibility.
Jann, Johann-Christoph; Nowak, Daniel; Nolte, Florian; Fey, Stephanie; Nowak, Verena; Obländer, Julia; Pressler, Jovita; Palme, Iris; Xanthopoulos, Christina; Fabarius, Alice; Platzbecker, Uwe; Giagounidis, Aristoteles; Götze, Katharina; Letsch, Anne; Haase, Detlef; Schlenk, Richard; Bug, Gesine; Lübbert, Michael; Ganser, Arnold; Germing, Ulrich; Haferlach, Claudia; Hofmann, Wolf-Karsten; Mossner, Maximilian
2017-01-01
Background Cytogenetic aberrations such as deletion of chromosome 5q (del(5q)) represent key elements in routine clinical diagnostics of haematological malignancies. Currently established methods such as metaphase cytogenetics, FISH or array-based approaches have limitations due to their dependency on viable cells, high costs or semi-quantitative nature. Importantly, they cannot be used on low abundance DNA. We therefore aimed to establish a robust and quantitative technique that overcomes these shortcomings. Methods For precise determination of del(5q) cell fractions, we developed an inexpensive multiplex-PCR assay requiring only nanograms of DNA that simultaneously measures allelic imbalances of 12 independent short tandem repeat markers. Results Application of this method to n=1142 samples from n=260 individuals revealed strong intermarker concordance (R²=0.77–0.97) and reproducibility (mean SD: 1.7%). Notably, the assay showed accurate quantification via standard curve assessment (R²>0.99) and high concordance with paired FISH measurements (R²=0.92) even with subnanogram amounts of DNA. Moreover, cytogenetic response was reliably confirmed in del(5q) patients with myelodysplastic syndromes treated with lenalidomide. While the assay demonstrated good diagnostic accuracy in receiver operating characteristic analysis (area under the curve: 0.97), we further observed robust correlation between bone marrow and peripheral blood samples (R²=0.79), suggesting its potential suitability for less-invasive clonal monitoring. Conclusions In conclusion, we present an adaptable tool for quantification of chromosomal aberrations, particularly in problematic samples, which should be easily applicable to further tumour entities. PMID:28600436
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Ryan T.; Wang, Chenchen; Rausch, Sarah J.
2014-07-01
A hybrid microchip/capillary CE system was developed to allow unbiased and lossless sample loading and high throughput repeated injections. This new hybrid CE system consists of a polydimethylsiloxane (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel and a fused silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channelmore » and the fused silica capillary separation column. Analytes are rapidly separated in the fused silica capillary with high resolution. High sensitivity MS detection after CE separation is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a good linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates and CE separation voltages.« less
Duangsang, Suampa; Tengtrisorn, Supaporn
2012-05-01
To determine the normal range of Central Corneal Light Reflex Ratio (CCLRR) from photographs of young adults. A digital camera equipped with a telephoto lens with a flash attachment placed directly above the lens was used to obtain corneal light reflex photographs of 104 subjects, first with the subject fixating on the lens of the camera at a distance of 43 centimeters, and then while looking past the camera to a wall at a distance of 5.4 meters. Digital images were displayed using Adobe Photoshop at a magnification of l200%. The CCLRR was the ratio of the sum of distances between the inner margin of cornea and the central corneal light reflex of each eye to the sum of horizontal corneal diameter of each eye. Measurements were made by three technicians on all subjects, and repeated on a 16% (n=17) subsample. Mean ratios (standard deviation-SD) from near/distance measurements were 0.468 (0.012)/0.452 (0.019). Limits of the normal range, with 95% certainty, were 0.448 and 0.488 for near measurements and 0.419 and 0.484 for distance measurements. Lower and upper indeterminate zones were 0.440-0.447 and 0.489-0.497 for near measurements and 0.406-0.418 and 0.485-0.497 for distance measurements. More extreme values can be considered as abnormal. The reproducibility and repeatability of the test was good. This method is easy to perform and has potential for use in strabismus screening by paramedical personnel.
Software-based evaluation of toric IOL orientation in a multicenter clinical study.
Kasthurirangan, Sanjeev; Feuchter, Lucas; Smith, Pamela; Nixon, Donald
2014-12-01
To evaluate the rotational stability of a new one-piece hydrophobic acrylic toric intraocular lens (IOL) using a custom-developed software for analysis of slit-lamp photographs. In a prospective, multicenter study, 174 eyes were implanted with the TECNIS Toric IOL (Abbott Medical Optics, Inc., Santa Ana, CA). A custom-developed software was used to analyze high-resolution slit-lamp photographs of 156 eyes taken at day 1 (baseline) and 1, 3, and 6 months postoperatively. The software uses iris and sclera landmarks to align the baseline image and later images for comparison. Validation of software was performed through repeated analyses of protractor images rotated from 0.1° to 10.0° and randomly selected photographs of 20 eyes. Software validation showed precision (repeatability plus reproducibility variation) of 0.02° using protractor images and 2.22° using slit-lamp photographs. Good quality slit-lamp images and clear landmarks were necessary for precise measurements. At 6 months, 94.2% of eyes had 5° or less change in IOL orientation versus baseline; only 2 eyes (1.4%) had axis shift greater than 30°. Most eyes were within 5° or less of rotation between 1 and 3 months (92.9%) and 3 and 6 months (94.1%). Mean absolute axis change (± standard deviation) from 1 day to 6 months was 2.70° ± 5.51°. The new custom software was precise and quick in analyzing slit-lamp photographs to determine postoperative toric IOL rotation. Copyright 2014, SLACK Incorporated.
Đurović, Ana; Stojanović, Zorica; Kravić, Snežana; Grahovac, Nada; Bursić, Vojislava; Vuković, Gorica; Suturović, Zvonimir
2016-01-01
A new electrochemical method for determination of imidacloprid using chronopotentiometry on thin film mercury and glassy carbon electrode was presented. The most important experimental parameters of chronopotentiometry were examined and optimized with respect to imidacloprid analytical signal. Imidacloprid provided well-defined reduction peak in Britton-Robinson buffer on thin film mercury electrode at −1.0 V (versus Ag/AgCl (KCl, 3.5 mol/L)) and on glassy carbon electrode at −1.2 V (versus Ag/AgCl (KCl, 3.5 mol/L)). The reduction time was linearly proportional to concentrations from 0.8 to 30.0 mg/L on thin film mercury electrode and from 7.0 to 70.0 mg/L on glassy carbon electrode. The detection limits were 0.17 mg/L and 0.93 mg/L for thin film mercury and glassy carbon electrode, respectively. The estimation of method precision as a function of repeatability and reproducibility showed relative standard deviations values lower than 3.73%. Recovery values from 97.3 to 98.1% confirmed the accuracy of the proposed method, while the constancy of the transition time with deliberated small changes in the experimental parameters indicated a very good robustness. A minor influence of possible interfering compounds proved good selectivity of the method. Developed method was applied for imidacloprid determination in commercial pesticide formulations and river water samples. PMID:27042181
Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan; Kim, Hae-Young
2014-03-01
This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.
Ottonello, Giuliana; Ferrari, Angelo; Magi, Emanuele
2014-01-01
A simple and robust method for the determination of 18 polychlorinated biphenyls (PCBs) in fish was developed and validated. A mixture of acetone/n-hexane (1:1, v/v) was selected for accelerated solvent extraction (ASE). After the digestion of fat, the clean-up was carried out using solid phase extraction silica cartridges. Samples were analysed by GC-MS in selected ion monitoring (SIM) using three fragment ions for each congener (one quantifier and two qualifiers). PCB 155 and PCB 198 were employed as internal standards. The lowest limit of detection was observed for PCB 28 (0.4ng/g lipid weight). The accuracy of the method was verified by means of the Certified Reference Material EDF-2525 and good results in terms of linearity (R(2)>0.994) and recoveries (80-110%) were also achieved. Precision was evaluated by spiking blank samples at 4, 8 and 12ng/g. Relative standard deviation values for repeatability and reproducibility were lower than 8% and 16%, respectively. The method was applied to the determination of PCBs in 80 samples belonging to four Mediterranean fish species. The proposed procedure is particularly effective because it provides good recoveries with lowered extraction time and solvent consumption; in fact, the total time of extraction is about 12min per sample and, for the clean-up step, a total solvent volume of 13ml is required. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ren, Ji-Yun; Wang, Xiao-Li; Li, Xiao-Li; Wang, Ming-Lin; Zhao, Ru-Song; Lin, Jin-Ming
2018-02-01
Covalent organic frameworks (COFs), which are a new type of carbonaceous polymeric material, have attracted great interest because of their large surface area and high chemical and thermal stability. However, to the best of our knowledge, no work has reported the use of magnetic COFs as adsorbents for magnetic solid-phase extraction (MSPE) to enrich and determine environmental pollutants. This work aims to investigate the feasibility of using covalent triazine-based framework (CTF)/Fe 2 O 3 composites as MSPE adsorbents to enrich and analyze perfluorinated compounds (PFCs) at trace levels in water samples. Under the optimal conditions, the method developed exhibited low limits of detection (0.62-1.39 ng·L -1 ), a wide linear range (5-4000 ng L -1 ), good repeatability (1.12-9.71%), and good reproducibility (2.45-7.74%). The new method was successfully used to determine PFCs in actual environmental water samples. MSPE based on CTF/Fe 2 O 3 composites exhibits potential for analysis of PFCs at trace levels in environmental water samples. Graphical abstract Magnetic covalent triazine-based frameworks (CTFs) were used as magnetic solid-phase extraction adsorbents for the sensitive determination of perfluorinated compounds in environmental water samples. PFBA perfluorobutyric acid, PFBS perfluorobutane sulfonate, PFDA perfluorodecanoic acid, PFDoA perfluorododecanoic acid, PFHpA perfluoroheptanoic acid, PFHxA perfluorohexanoic acid, PFHxS perfluorohexane sulfonate, PFNA perfluorononanoic acid, PFOA perfluorooctanoic acid, PFPeA perfluoropentanoic acid, PFUdA Perfluoroundecanoic acid.
Captur, Gabriella; Gatehouse, Peter; Keenan, Kathryn E; Heslinga, Friso G; Bruehl, Ruediger; Prothmann, Marcel; Graves, Martin J; Eames, Richard J; Torlasco, Camilla; Benedetti, Giulia; Donovan, Jacqueline; Ittermann, Bernd; Boubertakh, Redha; Bathgate, Andrew; Royet, Celine; Pang, Wenjie; Nezafat, Reza; Salerno, Michael; Kellman, Peter; Moon, James C
2016-09-22
T 1 mapping and extracellular volume (ECV) have the potential to guide patient care and serve as surrogate end-points in clinical trials, but measurements differ between cardiovascular magnetic resonance (CMR) scanners and pulse sequences. To help deliver T 1 mapping to global clinical care, we developed a phantom-based quality assurance (QA) system for verification of measurement stability over time at individual sites, with further aims of generalization of results across sites, vendor systems, software versions and imaging sequences. We thus created T1MES: The T1 Mapping and ECV Standardization Program. A design collaboration consisting of a specialist MRI small-medium enterprise, clinicians, physicists and national metrology institutes was formed. A phantom was designed covering clinically relevant ranges of T 1 and T 2 in blood and myocardium, pre and post-contrast, for 1.5 T and 3 T. Reproducible mass manufacture was established. The device received regulatory clearance by the Food and Drug Administration (FDA) and Conformité Européene (CE) marking. The T1MES phantom is an agarose gel-based phantom using nickel chloride as the paramagnetic relaxation modifier. It was reproducibly specified and mass-produced with a rigorously repeatable process. Each phantom contains nine differently-doped agarose gel tubes embedded in a gel/beads matrix. Phantoms were free of air bubbles and susceptibility artifacts at both field strengths and T 1 maps were free from off-resonance artifacts. The incorporation of high-density polyethylene beads in the main gel fill was effective at flattening the B 1 field. T 1 and T 2 values measured in T1MES showed coefficients of variation of 1 % or less between repeat scans indicating good short-term reproducibility. Temperature dependency experiments confirmed that over the range 15-30 °C the short-T 1 tubes were more stable with temperature than the long-T 1 tubes. A batch of 69 phantoms was mass-produced with random sampling of ten of these showing coefficients of variations for T 1 of 0.64 ± 0.45 % and 0.49 ± 0.34 % at 1.5 T and 3 T respectively. The T1MES program has developed a T 1 mapping phantom to CE/FDA manufacturing standards. An initial 69 phantoms with a multi-vendor user manual are now being scanned fortnightly in centers worldwide. Future results will explore T 1 mapping sequences, platform performance, stability and the potential for standardization.
Papaioannou, T G; Protogerou, A D; Nasothimiou, E G; Tzamouranis, D; Skliros, N; Achimastos, A; Papadogiannis, D; Stefanadis, C I
2012-10-01
Currently, there is no recommendation regarding the minimum number of pulse wave velocity (PWV) measurements to optimize individual's cardiovascular risk (CVR) stratification. The aim of this study was to examine differences between three single consecutive and averaged PWV measurements in terms of the extrapolated CVR and the classification of aortic stiffness as normal. In 60 subjects who referred for CVR assessment, three repeated measurements of blood pressure (BP), heart rate and PWV were performed. The reproducibility was evaluated by the intraclass correlation coefficient (ICC) and mean±s.d. of differences. The absolute differences between single and averaged PWV measurements were classified as: ≤0.25, 0.26-0.49, 0.50-0.99 and ≥1 m s(-1). A difference ≥0.5 m s(-1) (corresponding to 7.5% change in CVR, meta-analysis data from >12 000 subjects) was considered as clinically meaningful; PWV values (single or averaged) were classified as normal according to respective age-corrected normal values (European Network data). Kappa statistic was used to evaluate the agreement between classifications. PWV for the first, second and third measurement was 7.0±1.9, 6.9±1.9, 6.9±2.0 m s(-1), respectively (P=0.319); BP and heart rate did not vary significantly. A good reproducibility between single measurements was observed (ICC>0.94, s.d. ranged between 0.43 and 0.64 m s(-1)). A high percent with difference ≥0.5 m s(-1) was observed between: any pair of the three single PWV measurements (26.6-38.3%); the first or second single measurement and the average of the first and second (18.3%); any single measurement and the average of three measurements (10-20%). In only up to 5% a difference ≥0.5 m s(-1) was observed between the average of three and the average of any two PWV measurements. There was no significant agreement regarding PWV classification as normal between: the first or second measurement and the averaged PWV values. There was significant agreement in classification made by the average of the first two and the average of three PWV measurements (κ=0.85, P<0.001). Even when high reproducibility in PWV measurement is succeeded single measurements provide quite variable results in terms of the extrapolated CVR and the classification of aortic stiffness as normal. The average of two PWV measurements provides similar results with the average of three.
McCrory, Emma; McGuinness, Niall Jp; Ulhaq, Aman
2018-06-01
To determine the reproducibility of Index of Orthognathic Functional Treatment Need (IOFTN) scores derived from plaster casts and their three-dimensional (3D) digital equivalents. Pilot study, prospective analytical. UK hospital orthodontic department. Thirty casts and their digital equivalents, representing the pre-treatment malocclusions of patients requiring orthodontic-orthognathic surgical treatment, were scored by four clinicians using IOFTN. Casts were scanned using a 3Shape digital scanner and 3D models produced using OrthoAnalyzer TM (3Shape Ltd, Copenhagen, Denmark). Examiners independently determined the IOFTN scores for the casts and digital models, to test their inter- and intra-operator reliability using weighted Kappa scores. Intra-operator agreement with IOFTN major categories (1-5: treatment need) was very good for plaster casts (0.83-0.98) and good-very good for digital models (0.78-0.83). Inter-operator agreement was moderate-very good for casts (0.58-0.82) and good-very good for digital models (0.65-0.92). Intra-operator agreement with IOFTN sub-categories (1-14: feature of malocclusion) was good-very good for casts (0.70-0.97) and digital models (0.80-0.94). Inter-operator agreement was moderate-good for casts (0.53-0.77); and moderate-very good for the digital models (0.58-0.90). Digital models are an acceptable alternative to plaster casts for examining the malocclusion of patients requiring combined orthodontic-orthognathic surgical treatment and determining treatment need.
Yuan, Jianmin; Usman, Ammara; Reid, Scott A; King, Kevin F; Patterson, Andrew J; Gillard, Jonathan H; Graves, Martin J
2018-02-01
The purpose of this work is to evaluate the repeatability of a compressed sensing (CS) accelerated multi-contrast carotid protocol at 3 T. Twelve volunteers and eight patients with carotid disease were scanned on a 3 T MRI scanner using a CS accelerated 3-D black-blood multi-contrast protocol which comprises T 1 w, T 2 w and PDw without CS, and with a CS factor of 1.5 and 2.0. The volunteers were scanned twice, the lumen/wall area and wall thickness were measured for each scan. Eight patients were scanned once, the inter/intra-observer reproducibility of the measurements was calculated. In the repeated volunteer scans, the interclass correlation coefficient (ICC) for the wall area measurement using a CS factor of 1.5 in PDw, T 1 w and T 2 w were 0.95, 0.81, and 0.97, respectively. The ICC for lumen area measurement using a CS factor of 1.5 in PDw, T 1 w and T 2 w were 0.96, 0.92, and 0.96, respectively. In patients, the ICC for inter/intra-observer measurements of lumen/wall area, and wall thickness were all above 0.81 in all sequences. The results show a CS accelerated 3-D black-blood multi-contrast protocol is a robust and reproducible method for carotid imaging. Future protocol design could use CS to reduce the scanning time.
Balquet, L; Noury-Desvaux, B; Jaquinandi, V; Mahé, G
2015-02-01
Diet is a modifiable risk factor of atherosclerosis. A 14-item food frequency questionnaire (FFQ) has been developed. The reproducibility of this FFQ is unknown in a student population whereas its use could be of interest. This FFQ allows calculating different scores for different food groups involved in cardiovascular disease. The vascular dietary score (VDS) can be calculated. The VSD ranges from -17 to +19. The higher the VSD, the better diet. Reproducibility was assessed in sports faculty students using mean tests comparing measurement 1 and 2 (minimum time interval ≥ 7 days) and intra-class correlation (ICC) tests. Thirty students (50% men) were included in a French Sports Faculty. Time between two FFQ assessments was 19 ± 9 days. Mean VSD was 0.50 ± 3.70 for the first assessment and 0.30 ± 3.14 for the second one (non significant). Any score for each food group was statistically significant between the first and the second measurement. ICC of VSD was 0.68 [95% confidence interval: 0.43-0.83]. This FFQ that assesses a risky vascular diet has good reproducibility. This tool could be useful for large studies involving students. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Hackley, Paul C.
2014-01-01
Vitrinite reflectance generally is considered the most robust thermal maturity parameter available for application to hydrocarbon exploration and petroleum system evaluation. However, until 2011 there was no standardized methodology available to provide guidelines for vitrinite reflectance measurements in shale. Efforts to correct this deficiency resulted in publication of ASTM D7708-11: Standard test method for microscopical determination of the reflectance of vitrinite dispersed in sedimentary rocks. In 2012-2013, an interlaboratory exercise was conducted to establish precision limits for the measurement technique. Six samples, representing a wide variety of shale, were tested in duplicate by 28 analysts in 22 laboratories from 14 countries. Samples ranged from immature to overmature (Ro 0.31-1.53%), from organic-rich to organic-lean (1-22 wt.% total organic carbon), and contained Type I (lacustrine), Type II (marine), and Type III (terrestrial) kerogens. Repeatability values (difference between repetitive results from same operator, same conditions) ranged from 0.03-0.11% absolute reflectance, whereas reproducibility values (difference between results obtained on same test material by different operators, different laboratories) ranged from 0.12-0.54% absolute reflectance. Repeatability and reproducibility degraded consistently with increasing maturity and decreasing organic content. However, samples with terrestrial kerogens (Type III) fell off this trend, showing improved levels of reproducibility due to higher vitrinite content and improved ease of identification. Operators did not consistently meet the reporting requirements of the test method, indicating that a common reporting template is required to improve data quality. The most difficult problem encountered was the petrographic distinction of solid bitumens and low-reflecting inert macerals from vitrinite when vitrinite occurred with reflectance ranges overlapping the other components. Discussion among participants suggested this problem could not be corrected via kerogen concentration or solvent extraction and is related to operator training and background. Poor reproducibility (0.54% absolute reflectance, related to increased anisotropy?) in the highest maturity sample (Ro 1.53%) suggests that vitrinite reflectance is not a highly reliable parameter in such rocks. Future work will investigate opportunities to improve reproducibility in similar high maturity, organic-lean shale varieties.
Shankar, Sudha S.; Vella, Adrian; Raymond, Ralph H.; Staten, Myrlene A.; Calle, Roberto A.; Bergman, Richard N.; Cao, Charlie; Chen, Danny; Cobelli, Claudio; Dalla Man, Chiara; Deeg, Mark; Dong, Jennifer Q.; Lee, Douglas S.; Polidori, David; Robertson, R. Paul; Ruetten, Hartmut; Stefanovski, Darko; Vassileva, Maria T.; Weir, Gordon C.
2016-01-01
OBJECTIVE Standardized, reproducible, and feasible quantification of β-cell function (BCF) is necessary for the evaluation of interventions to improve insulin secretion and important for comparison across studies. We therefore characterized the responses to, and reproducibility of, standardized methods of in vivo BCF across different glucose tolerance states. RESEARCH DESIGN AND METHODS Participants classified as having normal glucose tolerance (NGT; n = 23), prediabetes (PDM; n = 17), and type 2 diabetes mellitus (T2DM; n = 22) underwent two standardized mixed-meal tolerance tests (MMTT) and two standardized arginine stimulation tests (AST) in a test-retest paradigm and one frequently sampled intravenous glucose tolerance test (FSIGT). RESULTS From the MMTT, insulin secretion in T2DM was >86% lower compared with NGT or PDM (P < 0.001). Insulin sensitivity (Si) decreased from NGT to PDM (∼50%) to T2DM (93% lower [P < 0.001]). In the AST, insulin secretory response to arginine at basal glucose and during hyperglycemia was lower in T2DM compared with NGT and PDM (>58%; all P < 0.001). FSIGT showed decreases in both insulin secretion and Si across populations (P < 0.001), although Si did not differ significantly between PDM and T2DM populations. Reproducibility was generally good for the MMTT, with intraclass correlation coefficients (ICCs) ranging from ∼0.3 to ∼0.8 depending on population and variable. Reproducibility for the AST was very good, with ICC values >0.8 across all variables and populations. CONCLUSIONS Standardized MMTT and AST provide reproducible and complementary measures of BCF with characteristics favorable for longitudinal interventional trials use. PMID:27407117
Shankar, Sudha S; Vella, Adrian; Raymond, Ralph H; Staten, Myrlene A; Calle, Roberto A; Bergman, Richard N; Cao, Charlie; Chen, Danny; Cobelli, Claudio; Dalla Man, Chiara; Deeg, Mark; Dong, Jennifer Q; Lee, Douglas S; Polidori, David; Robertson, R Paul; Ruetten, Hartmut; Stefanovski, Darko; Vassileva, Maria T; Weir, Gordon C; Fryburg, David A
2016-09-01
Standardized, reproducible, and feasible quantification of β-cell function (BCF) is necessary for the evaluation of interventions to improve insulin secretion and important for comparison across studies. We therefore characterized the responses to, and reproducibility of, standardized methods of in vivo BCF across different glucose tolerance states. Participants classified as having normal glucose tolerance (NGT; n = 23), prediabetes (PDM; n = 17), and type 2 diabetes mellitus (T2DM; n = 22) underwent two standardized mixed-meal tolerance tests (MMTT) and two standardized arginine stimulation tests (AST) in a test-retest paradigm and one frequently sampled intravenous glucose tolerance test (FSIGT). From the MMTT, insulin secretion in T2DM was >86% lower compared with NGT or PDM (P < 0.001). Insulin sensitivity (Si) decreased from NGT to PDM (∼50%) to T2DM (93% lower [P < 0.001]). In the AST, insulin secretory response to arginine at basal glucose and during hyperglycemia was lower in T2DM compared with NGT and PDM (>58%; all P < 0.001). FSIGT showed decreases in both insulin secretion and Si across populations (P < 0.001), although Si did not differ significantly between PDM and T2DM populations. Reproducibility was generally good for the MMTT, with intraclass correlation coefficients (ICCs) ranging from ∼0.3 to ∼0.8 depending on population and variable. Reproducibility for the AST was very good, with ICC values >0.8 across all variables and populations. Standardized MMTT and AST provide reproducible and complementary measures of BCF with characteristics favorable for longitudinal interventional trials use. © 2016 by the American Diabetes Association.
Minority game with arbitrary cutoffs
NASA Astrophysics Data System (ADS)
Johnson, N. F.; Hui, P. M.; Zheng, Dafang; Tai, C. W.
1999-07-01
We study a model of a competing population of N adaptive agents, with similar capabilities, repeatedly deciding whether to attend a bar with an arbitrary cutoff L. Decisions are based upon past outcomes. The agents are only told whether the actual attendance is above or below L. For L∼ N/2, the game reproduces the main features of Challet and Zhang's minority game. As L is lowered, however, the mean attendances in different runs tend to divide into two groups. The corresponding standard deviations for these two groups are very different. This grouping effect results from the dynamical feedback governing the game's time-evolution, and is not reproduced if the agents are fed a random history.
Actinic cheilitis: proposition and reproducibility of a clinical criterion.
Poitevin, Nádia Antunes; Rodrigues, Mariana Sudati; Weigert, Karen Loureiro; Macedo, Carmen Lúcia Rodrigues; Dos Santos, Rubem Beraldo
2017-01-01
The actinic cheilitis (AC) is a precancerous lip lesion seen as a consequence of chronic sun exposure. Clinically, the border between the lip's skin and the semimucosa could be blurred; in the more aggressive cases, leucoplakia and ulcers also represent its clinical feature. It seems that no clinical criterion is universally accepted for this disease yet. Therefore, this study was carried out to make a proposition of a clinical score to actinic cheilitis (Grade I starting from dryness of vermilion to endured ulcers representing Grade IV) and to assess its reproducibility. Fifty subjects were assessed, most of whom were male, Caucasian farmers, with an average age of 46.12 (18-74) years. The obtained data were analysed by means of descriptive statistics and by Kappa test to assess the inter-examiners and the clinical Golden-Pattern concordance (95% CI). During calibration, 15 patients were examined three times a week by each examiner (4) until Kappa test observed k =0.8 or more. In the main experiment, the inter-examiner concordance was classified between good ( k =0.779; P <0.05) and very good ( k =0.925; P <0.05) from the 35 examined subjects. With the Golden-Pattern, it was considered very good ( k =0.812; P <0.05 to k =0.925; P <0.05). Four examiners with different experiences could strongly suggest that after adequate calibration, it could be well applied by examiners with as much experience as a dental student. The authors concluded that the proposed classification was easily applied and had a very good reproducibility.
Machado, Roberta Ismael Lacerda; Souto, Lais Medeiros; Freire, Eutilia Andrade Medeiros
2014-01-01
Systemic sclerosis (SSc) is a multisystem disease, autoimmune disorder characterized by a fibroblastic disfunction, with significant impact on quality of life (QoL), measured by instruments or questionnaires that usually were formulated in other languages and in different cultural contexts. Translate into Brazilian Portuguese, cross cultural adaptation and assess the reliability and validity of the Systemic Sclerosis Questionnaire (SySQ). Translation and adaptation: into Portuguese and cross-cultural adaptation was performed in accordance with studies on questionnaire translation methodology into other languages. Reliability: it was analyzed using three interviews with different interviewers, two on the same day (interobserver) and the third within 14 days of the first assessment (intraobserver).Validity was assessed by correlating clinical and quality of life parameters with the domain scores of Sysc. a descriptive analysis of the study sample. Reproducibility was assessed using an intraclass correlation coefficient (ICC). Internal consistency was assessed using Cronbach's alpha coefficient. To assess validity we used Spearman correlation coefficient. Five percent was the level of significance adopted for all statistical tests. In the evaluation of the questionnaires, the results were similar to the original questionnaire, the internal consistency ranging between 0.73 and 0.93 for each item. The interobserver reproducibility was very good for all domains (α = 0.786 to 0.983) and intraobserver agreement was considered very good for general symptoms domain (ICC = 0.916), good for musculoskeletal symptoms domain (ICC = 0.897) and cardiopulmonary domain (ICC = 0.842) and reasonable for gastrointestinal symptoms domain (ICC = 0.686). The Brazilian Portuguese version of SySQ proved to be reproducible and valid for our population, using a recognized methodology for translation and cultural adaptation of questionnaires, as well as to assess the reproducibility and validity.
Understanding reproducibility of human IVF traits to predict next IVF cycle outcome.
Wu, Bin; Shi, Juanzi; Zhao, Wanqiu; Lu, Suzhen; Silva, Marta; Gelety, Timothy J
2014-10-01
Evaluating the failed IVF cycle often provides useful prognostic information. Before undergoing another attempt, patients experiencing an unsuccessful IVF cycle frequently request information about the probability of future success. Here, we introduced the concept of reproducibility and formulae to predict the next IVF cycle outcome. The experimental design was based on the retrospective review of IVF cycle data from 2006 to 2013 in two different IVF centers and statistical analysis. The reproducibility coefficients (r) of IVF traits including number of oocytes retrieved, oocyte maturity, fertilization, embryo quality and pregnancy were estimated using the interclass correlation coefficient between the repeated IVF cycle measurements for the same patient by variance component analysis. The formulae were designed to predict next IVF cycle outcome. The number of oocytes retrieved from patients and their fertilization rate had the highest reproducibility coefficients (r = 0.81 ~ 0.84), which indicated a very close correlation between the first retrieval cycle and subsequent IVF cycles. Oocyte maturity and number of top quality embryos had middle level reproducibility (r = 0.38 ~ 0.76) and pregnancy rate had a relative lower reproducibility (r = 0.23 ~ 0.27). Based on these parameters, the next outcome for these IVF traits might be accurately predicted by the designed formulae. The introduction of the concept of reproducibility to our human IVF program allows us to predict future IVF cycle outcomes. The traits of oocyte numbers retrieved, oocyte maturity, fertilization, and top quality embryos had higher or middle reproducibility, which provides a basis for accurate prediction of future IVF outcomes. Based on this prediction, physicians may counsel their patients or change patient's stimulation plans, and laboratory embryologists may improve their IVF techniques accordingly.
Enriched reproducing kernel particle method for fractional advection-diffusion equation
NASA Astrophysics Data System (ADS)
Ying, Yuping; Lian, Yanping; Tang, Shaoqiang; Liu, Wing Kam
2018-06-01
The reproducing kernel particle method (RKPM) has been efficiently applied to problems with large deformations, high gradients and high modal density. In this paper, it is extended to solve a nonlocal problem modeled by a fractional advection-diffusion equation (FADE), which exhibits a boundary layer with low regularity. We formulate this method on a moving least-square approach. Via the enrichment of fractional-order power functions to the traditional integer-order basis for RKPM, leading terms of the solution to the FADE can be exactly reproduced, which guarantees a good approximation to the boundary layer. Numerical tests are performed to verify the proposed approach.
NASA Technical Reports Server (NTRS)
Ploutz-Snyder, R. J.; Feiveson, A. H.
2015-01-01
Back by popular demand, the JSC Biostatistics Lab is offering an opportunity for informal conversation about challenges you may have encountered with issues of experimental design, analysis, data visualization or related topics. Get answers to common questions about sample size, repeated measures, violation of distributional assumptions, missing data, multiple testing, time-to-event data, when to trust the results of your analyses (reproducibility issues) and more.
Strengthening Transparency in Regulatory Science
Where available and appropriate, EPA will use peer-reviewed information, standardized test methods, consistent data evaluation procedures, and good laboratory practices to ensure transparent, understandable, and reproducible scientific assessments.
Specific NIST projects in support of the NIJ Concealed Weapon Detection and Imaging Program
NASA Astrophysics Data System (ADS)
Paulter, Nicholas G.
1998-12-01
The Electricity Division of the National Institute of Standards and Technology is developing revised performance standards for hand-held (HH) and walk-through (WT) metal weapon detectors, test procedures and systems for these detectors, and a detection/imaging system for finding concealed weapons. The revised standards will replace the existing National Institute of Justice (NIJ) standards for HH and WT devices and will include detection performance specifications as well as system specifications (environmental conditions, mechanical strength and safety, response reproducibility and repeatability, quality assurance, test reporting, etc.). These system requirements were obtained from the Law Enforcement and corrections Technology Advisory Council, an advisory council for the NIJ. Reproducible and repeatable test procedures and appropriate measurement systems will be developed for evaluating HH and WT detection performance. A guide to the technology and application of non- eddy-current-based detection/imaging methods (such as acoustic, passive millimeter-wave and microwave, active millimeter-wave and terahertz-wave, x-ray, etc.) Will be developed. The Electricity Division is also researching the development of a high- frequency/high-speed (300 GH to 1 THz) pulse-illuminated, stand- off, video-rate, concealed weapons/contraband imaging system.
NASA Astrophysics Data System (ADS)
Clapuyt, Francois; Vanacker, Veerle; Van Oost, Kristof
2016-05-01
Combination of UAV-based aerial pictures and Structure-from-Motion (SfM) algorithm provides an efficient, low-cost and rapid framework for remote sensing and monitoring of dynamic natural environments. This methodology is particularly suitable for repeated topographic surveys in remote or poorly accessible areas. However, temporal analysis of landform topography requires high accuracy of measurements and reproducibility of the methodology as differencing of digital surface models leads to error propagation. In order to assess the repeatability of the SfM technique, we surveyed a study area characterized by gentle topography with an UAV platform equipped with a standard reflex camera, and varied the focal length of the camera and location of georeferencing targets between flights. Comparison of different SfM-derived topography datasets shows that precision of measurements is in the order of centimetres for identical replications which highlights the excellent performance of the SfM workflow, all parameters being equal. The precision is one order of magnitude higher for 3D topographic reconstructions involving independent sets of ground control points, which results from the fact that the accuracy of the localisation of ground control points strongly propagates into final results.
NASA Astrophysics Data System (ADS)
Hammond, Emily; Dilger, Samantha K. N.; Stoyles, Nicholas; Judisch, Alexandra; Morgan, John; Sieren, Jessica C.
2015-03-01
Recent growth of genetic disease models in swine has presented the opportunity to advance translation of developed imaging protocols, while characterizing the genotype to phenotype relationship. Repeated imaging with multiple clinical modalities provides non-invasive detection, diagnosis, and monitoring of disease to accomplish these goals; however, longitudinal scanning requires repeatable and reproducible positioning of the animals. A modular positioning unit was designed to provide a fixed, stable base for the anesthetized animal through transit and imaging. Post ventilation and sedation, animals were placed supine in the unit and monitored for consistent vitals. Comprehensive imaging was performed with a computed tomography (CT) chest-abdomen-pelvis scan at each screening time point. Longitudinal images were rigidly registered, accounting for rotation, translation, and anisotropic scaling, and the skeleton was isolated using a basic thresholding algorithm. Assessment of alignment was quantified via eleven pairs of corresponding points on the skeleton with the first time point as the reference. Results were obtained with five animals over five screening time points. The developed unit aided in skeletal alignment within an average of 13.13 +/- 6.7 mm for all five subjects providing a strong foundation for developing qualitative and quantitative methods of disease tracking.
Reproducibility of the dynamics of facial expressions in unilateral facial palsy.
Alagha, M A; Ju, X; Morley, S; Ayoub, A
2018-02-01
The aim of this study was to assess the reproducibility of non-verbal facial expressions in unilateral facial paralysis using dynamic four-dimensional (4D) imaging. The Di4D system was used to record five facial expressions of 20 adult patients. The system captured 60 three-dimensional (3D) images per second; each facial expression took 3-4seconds which was recorded in real time. Thus a set of 180 3D facial images was generated for each expression. The procedure was repeated after 30min to assess the reproducibility of the expressions. A mathematical facial mesh consisting of thousands of quasi-point 'vertices' was conformed to the face in order to determine the morphological characteristics in a comprehensive manner. The vertices were tracked throughout the sequence of the 180 images. Five key 3D facial frames from each sequence of images were analyzed. Comparisons were made between the first and second capture of each facial expression to assess the reproducibility of facial movements. Corresponding images were aligned using partial Procrustes analysis, and the root mean square distance between them was calculated and analyzed statistically (paired Student t-test, P<0.05). Facial expressions of lip purse, cheek puff, and raising of eyebrows were reproducible. Facial expressions of maximum smile and forceful eye closure were not reproducible. The limited coordination of various groups of facial muscles contributed to the lack of reproducibility of these facial expressions. 4D imaging is a useful clinical tool for the assessment of facial expressions. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Molecular view of ligands specificity for CAG repeats in anti-Huntington therapy.
Bochicchio, Anna; Rossetti, Giulia; Tabarrini, Oriana; Krauβ, Sybille; Carloni, Paolo
2015-10-13
Huntington's disease is a fatal and devastating neurodegenerative genetic disorder for which there is currently no cure. It is characterized by Huntingtin protein's mRNA transcripts with 36 or more CAG repeats. Inhibiting the formation of pathological complexes between these expanded transcripts and target proteins may be a valuable strategy against the disease. Yet, the rational design of molecules specifically targeting the expanded CAG repeats is limited by the lack of structural information. Here, we use well-tempered metadynamics-based free energy calculations to investigate pose and affinity of two ligands targeting CAG repeats for which affinities have been previously measured. The first consists of two 4-guanidinophenyl rings linked by an ester group. It is the most potent ligand identified so far, with Kd = 60(30) nM. The second consists of a 4-phenyl dihydroimidazole and 4-1H-indole dihydroimidazole connected by a C-C bond (Kd = 700(80) nM). Our calculations reproduce the experimental affinities and uncover the recognition pattern between ligands' and their RNA target. They also provide a molecular basis for the markedly different affinity of the two ligands for CAG repeats as observed experimentally. These findings may pave the way for a structure-based hit-to-lead optimization to further improve ligand selectivity toward CAG repeat-containing mRNAs.
Martins, Cátia; Ferreira, Paulo Miguel; Carvalho, Raquel; Costa, Sandra Cristina; Farinha, Carlos; Azevedo, Luísa; Amorim, António; Oliveira, Manuela
2018-02-01
Obtaining a genetic profile from pieces of evidence collected at a crime scene is the primary objective of forensic laboratories. New procedures, methods, kits, software or equipment must be carefully evaluated and validated before its implementation. The constant development of new methodologies for DNA testing leads to a steady process of validation, which consists of demonstrating that the technology is robust, reproducible, and reliable throughout a defined range of conditions. The present work aims to internally validate two new retrotransposon-based kits (InnoQuant ® HY and InnoTyper ® 21), under the working conditions of the Laboratório de Polícia Científica da Polícia Judiciária (LPC-PJ). For the internal validation of InnoQuant ® HY and InnoTyper ® 21 sensitivity, repeatability, reproducibility, and mixture tests and a concordance study between these new kits and those currently in use at LPC-PJ (Quantifiler ® Duo and GlobalFiler™) were performed. The results obtained for sensitivity, repeatability, and reproducibility tests demonstrated that both InnoQuant ® HY and InnoTyper ® 21 are robust, reproducible, and reliable. The results of the concordance studies demonstrate that InnoQuant ® HY produced quantification results in nearly 29% more than Quantifiler ® Duo (indicating that this new kit is more effective in challenging samples), while the differences observed between InnoTyper ® 21 and GlobalFiler™ are not significant. Therefore, the utility of InnoTyper ® 21 has been proven, especially by the successful amplification of a greater number of complete genetic profiles (27 vs. 21). The results herein presented allowed the internal validation of both InnoQuant ® HY and InnoTyper ® 21, and their implementation in the LPC-PJ laboratory routine for the treatment of challenging samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou
2015-01-01
Background Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Materials and Methods Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. Results A total of 30 patients with facial deformity and malocclusion—10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate—were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. Conclusions The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models. PMID:25668209
Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou
2015-01-01
Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models.
Holland-Letz, Tim; Endres, Heinz G; Biedermann, Stefanie; Mahn, Matthias; Kunert, Joachim; Groh, Sabine; Pittrow, David; von Bilderling, Peter; Sternitzky, Reinhardt; Diehm, Curt
2007-05-01
The reliability of ankle-brachial index (ABI) measurements performed by different observer groups in primary care has not yet been determined. The aims of the study were to provide precise estimates for all effects influencing the variability of the ABI (patients' individual variability, intra- and inter-observer variability), with particular focus on the performance of different observer groups. Using a partially balanced incomplete block design, 144 unselected individuals aged > or = 65 years underwent double ABI measurements by one vascular surgeon or vascular physician, one family physician and one nurse with training in Doppler sonography. Three groups comprising a total of 108 individuals were analyzed (only two with ABI < 0.90). Errors for two repeated measurements for all three observer groups did not differ (experts 8.5%, family physicians 7.7%, and nurses 7.5%, p = 0.39). There was no relevant bias among observer groups. Intra-observer variability expressed as standard deviation divided by the mean was 8%, and inter-observer variability was 9%. In conclusion, reproducibility of the ABI measurement was good in this cohort of elderly patients who almost all had values in the normal range. The mean error of 8-9% within or between observers is smaller than with established screening measures. Since there were no differences among observers with different training backgrounds, our study confirms the appropriateness of ABI assessment for screening peripheral arterial disease (PAD) and generalized atherosclerosis in the primary case setting. Given the importance of the early detection and management of PAD, this diagnostic tool should be used routinely as a standard for PAD screening. Additional studies will be required to confirm our observations in patients with PAD of various severities.
Hillarp, A; Friedman, K D; Adcock-Funk, D; Tiefenbacher, S; Nichols, W L; Chen, D; Stadler, M; Schwartz, B A
2015-11-01
The ability of von Willebrand factor (VWF) to bind platelet GP Ib and promote platelet plug formation is measured in vitro using the ristocetin cofactor (VWF:RCo) assay. Automated assay systems make testing more accessible for diagnosis, but do not necessarily improve sensitivity and accuracy. We assessed the performance of a modified automated VWF:RCo assay protocol for the Behring Coagulation System (BCS(®) ) compared to other available assay methods. Results from different VWF:RCo assays in a number of specialized commercial and research testing laboratories were compared using plasma samples with varying VWF:RCo activities (0-1.2 IU mL(-1) ). Samples were prepared by mixing VWF concentrate or plasma standard into VWF-depleted plasma. Commercially available lyophilized standard human plasma was also studied. Emphasis was put on the low measuring range. VWF:RCo accuracy was calculated based on the expected values, whereas precision was obtained from repeated measurements. In the physiological concentration range, most of the automated tests resulted in acceptable accuracy, with varying reproducibility dependent on the method. However, several assays were inaccurate in the low measuring range. Only the modified BCS protocol showed acceptable accuracy over the entire measuring range with improved reproducibility. A modified BCS(®) VWF:RCo method can improve sensitivity and thus enhances the measuring range. Furthermore, the modified BCS(®) assay displayed good precision. This study indicates that the specific modifications - namely the combination of increased ristocetin concentration, reduced platelet content, VWF-depleted plasma as on-board diluent and a two-curve calculation mode - reduces the issues seen with current VWF:RCo activity assays. © 2015 John Wiley & Sons Ltd.
Uclés, A; Ulaszewska, M M; Hernando, M D; Ramos, M J; Herrera, S; García, E; Fernández-Alba, A R
2013-07-01
This work introduces a liquid chromatography-electrospray ionization-hybrid quadrupole/time-of-flight mass spectrometry (LC-ESI-QTOF-MS)-based method for qualitative and quantitative analysis of poly(amidoamine) (PAMAM) dendrimers of generations 0 to 3 in an aqueous matrix. The multiple charging of PAMAM dendrimers generated by means of ESI has provided key advantages in dendrimer identification by assignation of charge state through high resolution of isotopic clusters. Isotopic distribution in function of abundance of isotopes (12)C and (13)C yielded valuable and complementarity data for confident characterization. A mass accuracy below 3.8 ppm for the most abundant isotopes (diagnostic ions) provided unambiguous identification of PAMAM dendrimers. Validation of the LC-ESI-QTOF-MS method and matrix effect evaluation enabled reliable and reproducible quantification. The validation parameters, limits of quantification in the range of 0.012 to 1.73 μM, depending on the generation, good linear range (R > 0.996), repeatability (RSD < 13.4%), and reproducibility (RSD < 10.9%) demonstrated the suitability of the method for the quantification of dendrimers in aqueous matrices (water and wastewater). The added selectivity, achieved by multicharge phenomena, represents a clear advantage in screening aqueous mixtures due to the fact that the matrix had no significant effect on ionization, with what is evidenced by an absence of sensitivity loss in most generations of PAMAM dendrimers. Fig Liquid chromatography-electrospray ionization-hybrid quadrupole/time of flight mass spectrometry (LC-ESI-QTOF-MS) based method for qualitative and quantitative analysis of PAMAM dendrimers in aqueous matrix.
Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M
2017-05-01
With the increasing use of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS), computed tomography (CT) remains the standard for annulus sizing. However, 3D transesophageal echocardiography (TEE) has been an alternative in patients with contraindications to CT. We sought to (1) test the feasibility, accuracy, and reproducibility of prototype 3DTEE analysis software (Philips) for aortic annular measurements and (2) compare the new approach to the existing echocardiographic techniques. We prospectively studied 52 patients who underwent gated contrast CT, procedural 3DTEE, and TAVR. 3DTEE images were analyzed using novel semi-automated software designed for 3D measurements of the aortic root, which uses multiplanar reconstruction, similar to CT analysis. Aortic annulus measurements included area, perimeter, and diameter calculations from these measurements. The results were compared to CT-derived values. Additionally, 3D echocardiographic measurements (3D planimetry and mitral valve analysis software adapted for the aortic valve) were also compared to the CT reference values. 3DTEE image quality was sufficient in 90% of patients for aortic annulus measurements using the new software, which were in good agreement with CT (r-values: .89-.91) and small (<4%) inter-modality nonsignificant biases. Repeated measurements showed <10% measurements variability. The new 3D analysis was the more accurate and reproducible of the existing echocardiographic techniques. Novel semi-automated 3DTEE analysis software can accurately measure aortic annulus in patients with severe AS undergoing TAVR, in better agreement with CT than the existing methodology. Accordingly, intra-procedural TEE could potentially replace CT in patients where CT carries significant risk. © 2017, Wiley Periodicals, Inc.
[Optimization of cluster analysis based on drug resistance profiles of MRSA isolates].
Tani, Hiroya; Kishi, Takahiko; Gotoh, Minehiro; Yamagishi, Yuka; Mikamo, Hiroshige
2015-12-01
We examined 402 methicillin-resistant Staphylococcus aureus (MRSA) strains isolated from clinical specimens in our hospital between November 19, 2010 and December 27, 2011 to evaluate the similarity between cluster analysis of drug susceptibility tests and pulsed-field gel electrophoresis (PFGE). The results showed that the 402 strains tested were classified into 27 PFGE patterns (151 subtypes of patterns). Cluster analyses of drug susceptibility tests with the cut-off distance yielding a similar classification capability showed favorable results--when the MIC method was used, and minimum inhibitory concentration (MIC) values were used directly in the method, the level of agreement with PFGE was 74.2% when 15 drugs were tested. The Unweighted Pair Group Method with Arithmetic mean (UPGMA) method was effective when the cut-off distance was 16. Using the SIR method in which susceptible (S), intermediate (I), and resistant (R) were coded as 0, 2, and 3, respectively, according to the Clinical and Laboratory Standards Institute (CLSI) criteria, the level of agreement with PFGE was 75.9% when the number of drugs tested was 17, the method used for clustering was the UPGMA, and the cut-off distance was 3.6. In addition, to assess the reproducibility of the results, 10 strains were randomly sampled from the overall test and subjected to cluster analysis. This was repeated 100 times under the same conditions. The results indicated good reproducibility of the results, with the level of agreement with PFGE showing a mean of 82.0%, standard deviation of 12.1%, and mode of 90.0% for the MIC method and a mean of 80.0%, standard deviation of 13.4%, and mode of 90.0% for the SIR method. In summary, cluster analysis for drug susceptibility tests is useful for the epidemiological analysis of MRSA.
Multicenter performance evaluation of a second generation cortisol assay.
Vogeser, Michael; Kratzsch, Jürgen; Ju Bae, Yoon; Bruegel, Mathias; Ceglarek, Uta; Fiers, Tom; Gaudl, Alexander; Kurka, Hedwig; Milczynski, Christoph; Prat Knoll, Cristina; Suhr, Anna C; Teupser, Daniel; Zahn, Ingrid; Ostlund, Richard E
2017-05-01
Untreated disorders of the adrenocortical system, such as Cushing's or Addison's disease, can be fatal, and accurate quantification of a patient's cortisol levels is vital for diagnosis. The objective of this study was to assess the analytical performance of a new fully-automated Elecsys® Cortisol II assay (second generation) to measure cortisol levels in serum and saliva. Four European investigational sites assessed the intermediate precision and reproducibility of the Cortisol II assay (Roche Diagnostics) under routine conditions. Method comparisons of the Cortisol II assay vs. liquid chromatography-tandem mass spectrometry (LC-MS/MS), the gold standard for cortisol measurement, were performed. Cortisol reference ranges from three US sites were determined using samples from self-reported healthy individuals. The coefficients of variation (CVs) for repeatability, intermediate precision, and reproducibility for serum samples were ≤2.6%, ≤5.8%, and ≤9.5%, respectively, and for saliva were ≤4.4% and ≤10.9%, and ≤11.4%, respectively. Agreement between the Cortisol II assay and LC-MS/MS in serum samples was close, with a slope of 1.02 and an intercept of 4.473 nmol/L. Reference range samples were collected from healthy individuals (n=300) and serum morning cortisol concentrations (5-95th percentile) were 166.1-507 nmol/L and afternoon concentrations were 73.8-291 nmol/L. Morning, afternoon, and midnight saliva concentrations (95th percentile) were 20.3, 6.94, and 7.56 nmol/L, respectively. The Cortisol II assay had good precision over the entire measuring range and had excellent agreement with LC-MS/MS. This test was found suitable for routine diagnostic application and will be valuable for the diagnosis of adrenocortical diseases.
Keppens, Cleo; Palma, John F; Das, Partha M; Scudder, Sidney; Wen, Wei; Normanno, Nicola; Van Krieken, J Han; Sacco, Alessandra; Fenizia, Francesca; de Castro, David Gonzalez; Hönigschnabl, Selma; Kern, Izidor; Lopez-Rios, Fernando; Lozano, Maria D; Marchetti, Antonio; Halfon, Philippe; Schuuring, Ed; Setinek, Ulrike; Sorensen, Boe; Taniere, Phillipe; Tiemann, Markus; Vosmikova, Hana; Dequeker, Elisabeth M C
2018-04-25
Molecular testing of EGFR is required to predict the response likelihood to targeted therapy in non-small-cell lung cancer. Analysis of circulating tumor DNA in plasma may complement limitations of tumor tissue. This study evaluated the interlaboratory performance and reproducibility of the cobas EGFR Mutation Test v2 to detect EGFR variants in plasma. Fourteen laboratories received two identical panels of 27 single-blinded plasma samples. Samples were wild-type or spiked with plasmid DNA to contain seven common EGFR variants at six predefined concentrations from 50 to 5000 copies per mL. The circulating tumor DNA was extracted by the cobas cfDNA Sample Preparation kit, followed by duplicate analysis with the EGFRv2 kit (Roche Molecular Systems, Pleasanton, CA). Lowest sensitivities were obtained for the c.2156G>C p.(Gly719Ala) and c.2573T>G p.(Leu858Arg) variants for the lowest target copies. For all other variants, sensitivities varied between 96.3% and 100.0%. Specificities were all 98.8% to 100.0%. Coefficients of variation indicated good intra and interlaboratory repeatability and reproducibility, but increased for decreasing concentrations. Prediction models revealed a significant correlation for all variants between the pre-defined copy number and the observed semiquantitative index values which reflects the samples' plasma mutation load. This study demonstrates an overall robust performance of the EGFRv2 kit in plasma. Prediction models may be applied to estimate the plasma mutation load for diagnostic or research purposes. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Jena, G B; Chavan, Sapana
2017-10-01
The principles of Good Laboratory Practices (GLPs) are mainly intended for the laboratories performing studies for regulatory compliances. However, today GLP can be applied to broad disciplines of science to cater to the needs of the experimental objectives, generation of quality data and assay reproducibility. Considering its significance, it can now be applied in academics; industries as well as government set ups throughout the world. GLP is the best way to promote the reliability, reproducibility of the test data and hence facilitates the international acceptability. Now it is high time to translate and implement the concept of GLP beyond regulatory studies. Thus, it can pave the way for better understanding of scientific problems and help to maintain a good human and environmental health. Through this review, we have made an attempt to explore the uses of GLP principles in different fields of science and its acceptability as well as looking for its future perspectives. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Dudchenko, Oleksandr Ye; Pyeshkova, Viktoriya M.; Soldatkin, Oleksandr O.; Akata, Burcu; Kasap, Berna O.; Soldatkin, Alexey P.; Dzyadevych, Sergei V.
2016-02-01
The application of silicalite for improvement of enzyme adsorption on new stainless steel electrodes is reported. Glucose oxidase (GOx) was immobilized by two methods: cross-linking by glutaraldehyde (GOx-GA) and cross-linking by glutaraldehyde along with GOx adsorption on silicalite-modified electrode (SME) (GOx-SME-GA). The GOx-SME-GA biosensors were characterized by a four- to fivefold higher sensitivity than GOx-GA biosensor. It was concluded that silicalite together with GA sufficiently enhances enzyme adhesion on stainless steel electrodes. The developed GOx-SME-GA biosensors were characterized by good reproducibility of biosensor preparation (relative standard deviation (RSD)—18 %), improved signal reproducibility (RSD of glucose determination was 7 %), and good storage stability (29 % loss of activity after 18-day storage). A series of fruit juices and nectars was analyzed using GOx-SME-GA biosensor for determination of glucose concentration. The obtained results showed good correlation with the data of high-performance liquid chromatography (HPLC) ( R = 0.99).
Cifuentes, A; Valencia, J; Sanz, E; Sánchez, M J; Rodríguez-Delgado, M A
1997-08-22
A comparative study on the use of reversed-phase high-performance liquid chromatography (RP-HPLC) and capillary electrophoresis (CE) for the determination of debrisoquine (D) and its metabolite, 4-hydroxydebrisoquine (4-HD), in human urine is presented. Four different urine pre-treatments are compared for purification of samples prior to their injection in HPLC and CE. The use of a solid-phase extraction with a C18 cartridge provides the best results for the urine sample treatment, with good recoveries, i.e., 94.5% for D and 93.4% for 4-HD, and high reproducibility, i.e., R.S.D. N = 10 values of 1.7% and 1.2%, respectively. Under our separation conditions it is shown that CE is twice as fast and provides slightly better analysis time reproducibility than HPLC for this type of sample. Both the sensitivity and peak area reproducibility are better when HPLC is used. The two techniques show good agreement when employed for determination of phenotypes for hydroxylation, which seems to corroborate the usefulness of CE for this type of study.
Retrieval and Sleep Both Counteract the Forgetting of Spatial Information
ERIC Educational Resources Information Center
Antony, James W.; Paller, Ken A.
2018-01-01
Repeatedly studying information is a good way to strengthen memory storage. Nevertheless, testing recall often produces superior long-term retention. Demonstrations of this testing effect, typically with verbal stimuli, have shown that repeated retrieval through testing reduces forgetting. Sleep also benefits memory storage, perhaps through…
Reinstein, Dan Z; Yap, Timothy E; Carp, Glenn I; Archer, Timothy J; Gobbe, Marine
2014-03-01
To measure and compare the interobserver reproducibility of manifest refraction according to a standardized protocol for normal preoperative patients in a refractive surgery practice. Private clinic, London, United Kingdom. Retrospective case series. This retrospective study comprised patients attending 2 preoperative refractions before laser vision correction. The first manifest refraction was performed by 1 of 7 optometrists and the second manifest refraction by 1 of 2 surgeons, all trained using a standard manifest refraction protocol. Spherocylindrical data were converted into power vectors for analysis. The dioptric power differences between observers were calculated and analyzed. One thousand nine hundred twenty-two consecutive eyes were stratified into a myopia group and a hyperopia group and then further stratified by each surgeon-optometrist combination. The mean surgeon-optometrist dioptric power difference was 0.21 diopter (D) (range 0.15 to 0.32 D). The mean difference in spherical equivalent refraction was 0.03 D, with 95% of all refractions within ±0.44 D for all optometrist-surgeon combinations. The severity of myopic or hyperopic ametropia did not affect the interobserver reproducibility of the manifest refraction. There was close agreement in refraction between surgeons and optometrists using a standard manifest refraction protocol of less than 0.25 D. This degree of interobserver repeatability is similar to that in intraobserver repeatability studies published to date and may represent the value of training and the use of a standard manifest refraction protocol between refraction observers in a refractive surgery practice involving co-management between surgeons and optometrists. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Evaluation of guidewire path reproducibility
Schafer, Sebastian; Hoffmann, Kenneth R.; Noël, Peter B.; Ionita, Ciprian N.; Dmochowski, Jacek
2008-01-01
The number of minimally invasive vascular interventions is increasing. In these interventions, a variety of devices are directed to and placed at the site of intervention. The device used in almost all of these interventions is the guidewire, acting as a monorail for all devices which are delivered to the intervention site. However, even with the guidewire in place, clinicians still experience difficulties during the interventions. As a first step toward understanding these difficulties and facilitating guidewire and device guidance, we have investigated the reproducibility of the final paths of the guidewire in vessel phantom models on different factors: user, materials and geometry. Three vessel phantoms (vessel diameters ∼4 mm) were constructed having tortuousity similar to the internal carotid artery from silicon tubing and encased in Sylgard elastomer. Several trained users repeatedly passed two guidewires of different flexibility through the phantoms under pulsatile flow conditions. After the guidewire had been placed, rotational c-arm image sequences were acquired (9 in. II mode, 0.185 mm pixel size), and the phantom and guidewire were reconstructed (5123, 0.288 mm voxel size). The reconstructed volumes were aligned. The centerlines of the guidewire and the phantom vessel were then determined using region-growing techniques. Guidewire paths appear similar across users but not across materials. The average root mean square difference of the repeated placement was 0.17±0.02 mm (plastic-coated guidewire), 0.73±0.55 mm (steel guidewire) and 1.15±0.65 mm (steel versus plastic-coated). For a given guidewire, these results indicate that the guidewire path is relatively reproducible in shape and position. PMID:18561663
Hwa, Kuo-Yuan; Subramani, Boopathi
2014-12-15
Synthesis of zinc oxide nanoparticles incorporated graphene-carbon nanotubes hybrid (GR-CNT-ZnO) through a simple, one-pot method is demonstrated. The as-synthesized GR-CNT-ZnO composite is applied to fabricate an enzyme based glucose biosensor. The GOx immobilized on GR-CNT-ZnO composite exhibits well-defined redox peaks with a peak potential separation (ΔEp) of about 26 mV with enhanced peak currents, indicating a fast electron transfer at the modified electrode surface. The cyclic voltammetry measurements revealed that the modified film has high electrocatalytic ability towards glucose detection in the presence of oxygen. The proposed sensor has a wide linear detection range from 10 μM to 6.5 mM of glucose with a limit of detection (LOD) of 4.5 (±0.08) μM. In addition, the sensor possessed appreciable repeatability, reproducibility and remarkable stability for the sensitive determination of glucose. The practicality of this sensor has been demonstrated in human serum samples, with results being in good agreement with those determined using a standard photometric method. Copyright © 2014 Elsevier B.V. All rights reserved.
Alcohol biosensing by polyamidoamine (PAMAM)/cysteamine/alcohol oxidase-modified gold electrode.
Akin, Mehriban; Yuksel, Merve; Geyik, Caner; Odaci, Dilek; Bluma, Arne; Höpfner, Tim; Beutel, Sascha; Scheper, Thomas; Timur, Suna
2010-01-01
A highly stable and sensitive amperometric alcohol biosensor was developed by immobilizing alcohol oxidase (AOX) through Polyamidoamine (PAMAM) dendrimers on a cysteamine-modified gold electrode surface. Ethanol determination is based on the consumption of dissolved oxygen content due to the enzymatic reaction. The decrease in oxygen level was monitored at -0.7 V vs. Ag/AgCl and correlated with ethanol concentration. Optimization of variables affecting the system was performed. The optimized ethanol biosensor showed a wide linearity from 0.025 to 1.0 mM with 100 s response time and detection limit of (LOD) 0.016 mM. In the characterization studies, besides linearity some parameters such as operational and storage stability, reproducibility, repeatability, and substrate specificity were studied in detail. Stability studies showed a good preservation of the bioanalytical properties of the sensor, 67% of its initial sensitivity was kept after 1 month storage at 4 degrees C. The analytical characteristics of the system were also evaluated for alcohol determination in flow injection analysis (FIA) mode. Finally, proposed biosensor was applied for ethanol analysis in various alcoholic beverage as well as offline monitoring of alcohol production through the yeast cultivation. Copyright 2010 American Institute of Chemical Engineers
Yu, Hong-Wei; Jiang, Jing-Hui; Zhang, Ze; Wan, Guang-Cai; Liu, Zhi-Yong; Chang, Dong; Pan, Hong-Zhi
2017-02-15
The assembly of quantum dots (QDs) in a simply method opens up opportunities to obtain access to the full potential of assembled QDs by virtue of the collective properties of the ensembles. In this study, quantum dots CdTe and graphene (Gr) nanocomposite was constructed for the simultaneous determination of uric acid (UA) and dopamine (DA). The CdTe QDs-Gr nanocomposite was prepared by ultrasonication and was characterized with microscopic techniques. The nanocomposite modified electrode was characterized by cyclicvoltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Due to the synergistic effects between CdTe QDs and Gr, the fabricated electrode exhibited excellent electrochemical catalytic activities, good biological compatibility and high sensitivity toward the oxidation of UA and DA. Under optimum conditions, in the co-existence system the linear calibration plots for UA and DA were obtained over the range of 3-600 μM and 1-500 μM with detection limits of 1.0 μM and 0.33 μM. The fabricated biosensor also exhibits the excellent repeatability, reproducibility, storage stability along with acceptable selectivity. Copyright © 2016. Published by Elsevier Inc.
A simple preparation of graphite/gelatin composite for electrochemical detection of dopamine.
Rajkumar, Chellakannu; Thirumalraj, Balamurugan; Chen, Shen-Ming; Chen, His-An
2017-02-01
In this study, we demonstrate a simple preparation of graphite (GR) sheets assisted with gelatin (GLN) polypeptide composite was developed for sensitive detection of dopamine (DA) sensor. The GR/GLN composite was prepared by GR powder in GLN solution (5mg/mL) via sonication process. The prepared GR/GLN composite displays well dispersion ability in biopolymer matrix and characterized via scanning electron microscope (SEM), Fourier transform infrared (FTIR) spectroscopy and electrochemical impedance spectroscopy (EIS) studies. The GR/GLN modified electrode showed an excellent electrocatalytic activity toward the oxidation of DA, suggesting that the successful formation of GR sheets crosslinked with the functional groups of GLN polypeptide. In addition, the GR/GLN modified electrode achieved a wide linear response ranging from 0.05 to 79.5μM with a detection limit of 0.0045μM. The calculated analytical sensitivity of the sensor was 1.36±0.02μAμM -1 cm -2 . Conversely, the modified electrode demonstrates a good storage stability, reproducibility and repeatability. In addition, the sensor manifests the determination of DA in human serum and urine samples for practical applications. Copyright © 2016 Elsevier Inc. All rights reserved.
Determining stability in connected speech in primary progressive aphasia and Alzheimer's disease.
Beales, Ashleigh; Whitworth, Anne; Cartwright, Jade; Panegyres, Peter K; Kane, Robert T
2018-03-08
Using connected speech to assess progressive language disorders is confounded by uncertainty around whether connected speech is stable over successive sampling, and therefore representative of an individual's performance, and whether some contexts and/or language behaviours show greater stability than others. A repeated measure, within groups, research design was used to investigate stability of a range of behaviours in the connected speech of six individuals with primary progressive aphasia and three individuals with Alzheimer's disease. Stability was evaluated, at a group and individual level, across three samples, collected over 3 weeks, involving everyday monologue, narrative and picture description, and analysed for lexical content, fluency and communicative informativeness and efficiency. Excellent and significant stability was found on the majority of measures, at a group and individual level, across all genres, with isolated measures (e.g. nouns use, communicative efficiency) showing good, but greater variability, within one of the three genres. Findings provide evidence of stability on measures of lexical content, fluency and communicative informativeness and efficiency. While preliminary evidence suggests that task selection is influential when considering stability of particular connected speech measures, replication over a larger sample is necessary to reproduce findings.
Skiera, Christina; Steliopoulos, Panagiotis; Kuballa, Thomas; Diehl, Bernd; Holzgrabe, Ulrike
2014-05-01
Indices like acid value, peroxide value, and saponification value play an important role in quality control and identification of lipids. Requirements on these parameters are given by the monographs of the European pharmacopeia. (1)H NMR spectroscopy provides a fast and simple alternative to these classical approaches. In the present work a new (1)H NMR approach to determine the acid value is described. The method was validated using a statistical approach based on a variance components model. The performance under repeatability and in-house reproducibility conditions was assessed. We applied this (1)H NMR assay to a wide range of different fatty oils. A total of 305 oil and fat samples were examined by both the classical and the NMR method. Except for hard fat, the data obtained by the two methods were in good agreement. The (1)H NMR method was adapted to analyse waxes and oleyloleat. Furthermore, the effect of solvent and in the case of castor oil the effect of the oil matrix on line broadening and chemical shift of the carboxyl group signal are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Neurogenic bowel dysfunction (NBD) translation and linguistic validation to classical Arabic.
Mallek, A; Elleuch, M H; Ghroubi, S
2016-09-01
To translate and linguistically validate in classical Arabic; the French version of the neurogenic bowel dysfunction (NBD). Arabic translation of the NBD score was obtained by the "forward translation/backword translation" method. Patients with multiple sclerosis (MS) and spinal cord injury were included. Evaluation of intestinal and anorectal disorders was conducted by the self-administered questionnaire NBD, which was filled twice two weeks apart. An item-by-item analysis was made. The feasibility, acceptability, internal consistency using Cronbach's alpha, and test-retest repeatability by non-parametric Spearman correlation were studied. Twenty-three patients with colorectal disorders secondary to neurological disease were included, the average age was 40.79±9.16years and the sex-ratio was 1.85. The questionnaire was feasible and acceptable, no items were excluded. The spearman correlation was of 0.842. Internal consistency was judged good through the Cronbach's alpha was of 0.896. The Arabic version of NBD was reproducible and construct validity was satisfactory. The study of its responsiveness to change with a larger number of patients will be the subject of further work. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Gevaerd, Ava; de Oliveira, Paulo R; Mangrich, Antonio S; Bergamini, Márcio F; Marcolino-Junior, Luiz H
2016-05-01
This work describes the construction and application of carbon paste electrodes modified with biochar and antimony microparticles (SbBCPE) for voltammetric determination of paraquat using a simple and sensitive procedure based on voltammetric stripping analysis. Some parameters such as amount of biochar and antimony used in the composition of the carbon paste and instrumental parameters were examined in detail. Under optimized conditions, an analytical curve was obtained for paraquat determination employing SbBCPE, which showed a linear response ranging from 0.2 to 2.9 μmol L(-1), with limit of detection and quantification of 34 nmol L(-1) and 113 nmol L(-1), respectively, after paraquat pre-concentration of 120 s. The repeatability study presented a RSD=2.0% for 10 consecutive measurements using the same electrode surface and the reproducibility study showed a RSD=2.7% for measurements with 10 different electrode surfaces. The proposed sensor was successfully applied for paraquat determination in tap water and citric fruit juice spiked samples and good recoveries were obtained without any sample pre-treatment, showing its promising analytical performance. Copyright © 2016 Elsevier B.V. All rights reserved.
Farajzadeh, Mirali; Hatami, Mehdi
2002-11-01
This work describes the application of the previously presented solid phase microextraction (SPME) fiber in direct mode for sampling of C10-C20 n-alkanes from aqueous solution. The fiber has simple composition and is constructed from activated charcoal:PVC suspension in tetrahydrofuran. When the composition of the fiber was optimized that the optimum composition was 90:10 (activated charcoal:PVC) for direct mode, whereas it was 75:25 for sampling from the headspace of aqueous samples. This fiber is completely stable in contact with water. The extraction efficiency is improved in the presence of 0.1 M NaCl. The value is between 17.8-38.5% for the first extraction, which better than the efficiency of similar commercial fibers. After seven extractions, all analytes are removed from the aqueous samples nearly 100%. Single fiber repeatability and fiber-to-fiber reproducibility are good and both are less than 13% for all studied alkanes. Finally, direct mode SPME was used in the determination of n-alkanes in the range of sub microg L(-1) without any additional preconcentration procedure. Gas chromatography along with flame ionization detection were used for separation and detection of the studied analytes.
New horizons in selective laser sintering surface roughness characterization
NASA Astrophysics Data System (ADS)
Vetterli, M.; Schmid, M.; Knapp, W.; Wegener, K.
2017-12-01
Powder-based additive manufacturing of polymers and metals has evolved from a prototyping technology to an industrial process for the fabrication of small to medium series of complex geometry parts. Unfortunately due to the processing of powder as a basis material and the successive addition of layers to produce components, a significant surface roughness inherent to the process has been observed since the first use of such technologies. A novel characterization method based on an elastomeric pad coated with a reflective layer, the Gelsight, was found to be reliable and fast to characterize surfaces processed by selective laser sintering (SLS) of polymers. With help of this method, a qualitative and quantitative investigation of SLS surfaces is feasible. Repeatability and reproducibility investigations are performed for both 2D and 3D areal roughness parameters. Based on the good results, the Gelsight is used for the optimization of vertical SLS surfaces. A model built on laser scanning parameters is proposed and after confirmation could achieve a roughness reduction of 10% based on the S q parameter. The Gelsight could be successfully identified as a fast, reliable and versatile surface topography characterization method as it applies to all kind of surfaces.
Evidence-based dentistry: analysis of dental anxiety scales for children.
Al-Namankany, A; de Souza, M; Ashley, P
2012-03-09
To review paediatric dental anxiety measures (DAMs) and assess the statistical methods used for validation and their clinical implications. A search of four computerised databases between 1960 and January 2011 associated with DAMs, using pre-specified search terms, to assess the method of validation including the reliability as intra-observer agreement 'repeatability or stability' and inter-observer agreement 'reproducibility' and all types of validity. Fourteen paediatric DAMs were predominantly validated in schools and not in the clinical setting while five of the DAMs were not validated at all. The DAMs that were validated were done so against other paediatric DAMs which may not have been validated previously. Reliability was not assessed in four of the DAMs. However, all of the validated studies assessed reliability which was usually 'good' or 'acceptable'. None of the current DAMs used a formal sample size technique. Diversity was seen between the studies ranging from a few simple pictograms to lists of questions reported by either the individual or an observer. To date there is no scale that can be considered as a gold standard, and there is a need to further develop an anxiety scale with a cognitive component for children and adolescents.
Troy, Karen L; Edwards, W Brent
2018-05-01
Quantitative CT (QCT) analysis involves the calculation of specific parameters such as bone volume and density from CT image data, and can be a powerful tool for understanding bone quality and quantity. However, without careful attention to detail during all steps of the acquisition and analysis process, data can be of poor- to unusable-quality. Good quality QCT for research requires meticulous attention to detail and standardization of all aspects of data collection and analysis to a degree that is uncommon in a clinical setting. Here, we review the literature to summarize practical and technical considerations for obtaining high quality QCT data, and provide examples of how each recommendation affects calculated variables. We also provide an overview of the QCT analysis technique to illustrate additional opportunities to improve data reproducibility and reliability. Key recommendations include: standardizing the scanner and data acquisition settings, minimizing image artifacts, selecting an appropriate reconstruction algorithm, and maximizing repeatability and objectivity during QCT analysis. The goal of the recommendations is to reduce potential sources of error throughout the analysis, from scan acquisition to the interpretation of results. Copyright © 2018 Elsevier Inc. All rights reserved.
Xu, Lili; Feng, Juanjuan; Li, Jubai; Liu, Xia; Jiang, Shengxiang
2012-01-01
A novel chemically bonded graphene oxide/fused-silica fiber was prepared and applied in solid-phase microextraction of six polycyclic aromatic hydrocarbons from water samples coupled with gas chromatography. It exhibited high extraction efficiency and excellent stability. Effects of extraction time, extraction temperature, ionic strength, stirring rate and desorption conditions were investigated and optimized in our work. Detection limits to the six polycyclic aromatic hydrocarbons were less than 0.08 μg/L, and their calibration curves were all linear (R(2)≥0.9954) in the range from 0.05 to 200 μg/L. Single fiber repeatability and fiber-to-fiber reproducibility were less than 6.13 and 15.87%, respectively. This novel fiber was then utilized to analyze two real water samples from the Yellow River and local waterworks, and the recoveries of samples spiked at 1 and 10 μg/L ranged from 84.48 to 118.24%. Compared with other coating materials, this graphene oxide-coated fiber showed many advantages: wide linear range, low detection limit, and good stability in acid, alkali, organic solutions and at high temperature. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ghaedi, Hamed; Afkhami, Abbas; Madrakian, Tayyebeh; Soltani-Felehgari, Farzaneh
2016-02-01
A new chemically modified carbon paste electrode (CMCPE) was applied to the simple, rapid, highly selective and sensitive determination of citalopram in human serum and pharmaceutical preparations using adsorptive square wave voltammetry (ASWV). The ZnO nanoparticles and multi-walled carbon nanotubes modified CPE (ZnO-MWCNT/CPE) electrode was prepared by incorporation of the ZnO nanoparticles and multi-walled carbon nanotubes (MWCNT) in carbon paste electrode. The limit of detection and the linear range were found to be 0.005 and 0.012 to 1.54μmolL(-1) of citalopram, respectively. The effects of potentially interfering substances on the determination of this compound were investigated and found that the electrode is highly selective. The proposed CMCPE was used to the determination of citalopram in human serum, urine and pharmaceutical samples. This reveals that ZnO-MWCNT/CPE shows excellent analytical performance for the determination of citalopram in terms of very low detection limit, high sensitivity, very good repeatability and reproducibility over other methods reported in the literature. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Ma, Weiwei; Wan, Xiuquan; Wang, Zhankun; Liu, Yulong; Wan, Kai
2017-12-01
The influence of high-frequency atmospheric forcing on the formation of a well-mixed summer warm water column in the central Bohai Sea is investigated comparing model simulations driven by daily surface forcing and those using monthly forcing data. In the absence of high-frequency atmospheric forcing, numerical simulations have repeatedly failed to reproduce this vertically uniform column of warm water measured over the past 35 years. However, high-frequency surface forcing is found to strongly influence the structure and distribution of the well-mixed warm water column, and simulations are in good agreement with observations. Results show that high frequency forcing enhances vertical mixing over the central bank, intensifies downward heat transport, and homogenizes the water column to form the Bohai central warm column. Evidence presented shows that high frequency forcing plays a dominant role in the formation of the well-mixed warm water column in summer, even without the effects of tidal and surface wave mixing. The present study thus provides a practical and rational way of further improving the performance of oceanic simulations in the Bohai Sea and can be used to adjust parameterization schemes of ocean models.
Optimization of myocardial deformation imaging in term and preterm infants.
Poon, Chuen Y; Edwards, Julie M; Joshi, Suchita; Kotecha, Sailesh; Fraser, Alan G
2011-03-01
Myocardial deformation imaging is now used to assess regional ventricular function in infants but their small size presents particular technical challenges. We therefore investigated the determinants of reproducibility of myocardial longitudinal strain (ε) in term and preterm infants, in order to determine optimal technical settings. Repeated longitudinal ε measurements of the mid-segments of the septum, and the left and right ventricular free walls, were performed using five different computation distances (CDs; also called strain length) in 20 infants. The coefficients of variation (CV) were calculated for each CD. Overall, ε measurements were most reproducible with a CD of 6 mm (CV 11.7%). In preterm infants (<34 weeks gestation; mean ± SD diastolic LV length, 20.3 ± 3.5 mm), ε measurements were most reproducible with CD of 6 mm (CV 7.2%); in term infants (>37 weeks gestation; mean ± SD diastolic LV length, 29.6 ± 3.0 mm), ε measurements were most reproducible with CD of 10 mm (CV 13.2%). The reproducibility of measuring ε increased with higher frame rates, from CV of 17.3% at frame rates <180 per s to 11.7% for frame rates >180 per s and 9.6% for rates >248 per s. In newborn infants, tissue Doppler loops should be acquired at frame rates above 180 per s. Myocardial deformation analysis of preterm infants should be performed using a CD of 6 mm, whereas a CD of 10 mm is more reproducible in term infants.
Sánchez-Ayala, Alfonso; Vilanova, Larissa Soares Reis; Costa, Marina Abrantes; Farias-Neto, Arcelino
2014-01-01
The aim of this study was to evaluate the reproducibility of the condensation silicone Optosil Comfort® as an artificial test food for masticatory performance evaluation. Twenty dentate subjects with mean age of 23.3±0.7 years were selected. Masticatory performance was evaluated using the simple (MPI), the double (IME) and the multiple sieve methods. Trials were carried out five times by three examiners: three times by the first, and once by the second and third examiners. Friedman's test was used to find the differences among time trials. Reproducibility was determined by the intra-class correlation (ICC) test (α=0.05). No differences among time trials were found, except for MPI-4 mm (p=0.022) from the first examiner results. The intra-examiner reproducibility (ICC) of almost all data was high (ICC≥0.92, p<0.001), being moderate only for MPI-0.50 mm (ICC=0.89, p<0.001). The inter-examiner reproducibility was high (ICC>0.93, p<0.001) for all results. For the multiple sieve method, the average mean of absolute difference from repeated measurements were lower than 1 mm. This trend was observed only from MPI-0.50 to MPI-1.4 for the single sieve method, and from IME-0.71/0.50 to IME-1.40/1.00 for the double sieve method. The results suggest that regardless of the method used, the reproducibility of Optosil Comfort® is high.
Data Identifiers and Citations Enable Reproducible Science
NASA Astrophysics Data System (ADS)
Tilmes, C.
2011-12-01
Modern science often involves data processing with tremendous volumes of data. Keeping track of that data has been a growing challenge for data center. Researchers who access and use that data don't always reference and cite their data sources adequately for consumers of their research to follow their methodology or reproduce their analyses or experiments. Recent research has led to recommendations for good identifiers and citations that can help address this problem. This paper will describe some of the best practices in data identifiers, reference and citation. Using a simplified example scenario based on a long term remote sensing satellite mission, it will explore issues in identifying dynamic data sets and the importance of good data citations for reproducibility. It will describe the difference between granule and collection level identifiers, using UUIDs and DOIs to illustrate some recommendations for developing identifiers and assigning them during data processing. As data processors create data products, the provenance of the input products and precise steps that led to their creation are recorded and published for users of the data to see. As researchers access the data from an archive, they can use the provenance to help understand the genesis of the data, which could have effects on their usage of the data. By citing the data on publishing their research, others can retrieve the precise data used in their research and reproduce the analyses and experiments to confirm the results. Describing the experiment to a sufficient extent to reproduce the research enforces a formal approach that lends credibility to the results, and ultimately, to the policies of decision makers depending on that research.
Villain, Max A; Greenfield, David S
2003-01-01
To assess reproducibility of quadrantic and clock hour sectors of retinal nerve fiber layer thickness in normal eyes using optical coherence tomography. Normal eyes of healthy volunteers meeting eligibility criteria were imaged by two inexperienced operators. Six 360 degrees circular scans with a diameter of 3.4 mm centered on the optic disc were obtained during each scanning session, and a baseline image was formed using 3 high-quality images defined by the software. Images were obtained on three different days within a 4-week period. Variance and coefficient of variation (CV) were calculated for quadrantic and retinal nerve fiber layer clock hour sectors obtained from the baseline image. Five normal eyes were scanned. Intraoperator reproducibility was high. The mean (+/- SD) CV for total retinal nerve fiber layer thickness was 5.3 +/- 3.82% and 4.33 +/- 3.7% for operators 1 and 2, respectively. Interoperator reproducibility was good with statistically similar variance for all quadrantic and clock hour retinal nerve fiber layer parameters (P = .42 to .99). The nasal retinal nerve fiber layer was the most variable sector for both operators (mean CV: 10.42% and 7.83% for operators 1 and 2, respectively). Differences in mean total, nasal, temporal, and superior retinal nerve fiber layer thickness were not statistically significant between operators for all eyes; however, for inferior retinal nerve fiber layer thickness, there was a significant (P = .0007) difference between operators in one eye. Peripapillary retinal nerve fiber layer thickness assessments using optical coherence tomography have good intraoperator and interoperator reproducibility. Inexperienced operators can generate useful measurement data with acceptable levels of variance.
NASA Astrophysics Data System (ADS)
Lai, Yi-Chen; Ho, Hsin-Chia; Shih, Bo-Wei; Tsai, Feng-Yu; Hsueh, Chun-Hway
2018-05-01
Surface-enhanced Raman scattering (SERS) substrate with a higher surface area, enhanced light harvesting, multiple hot spots and strong electromagnetic field enhancements would exhibit enhanced Raman signals. Herein, the Ag nanoparticle/ZnO nanowire heterostructure decorated periodic silicon nanotube (Ag@ZnO@SiNT) substrate was proposed and fabricated. The proposed structure employed as SERS-active substrate was examined, and the results showed both the high performance in terms of high sensitivity and good reproducibility. Furthermore, the Ag@ZnO@SiNT substrate demonstrated the self-cleaning performance through the photocatalytic degradation of probed molecules upon UV-irradiation. The results showed that the proposed nanostructure had high performance, good reproducibility and reusability, and it is a promising SERS-active substrate for molecular sensing and cleaning.
Tools and techniques for computational reproducibility.
Piccolo, Stephen R; Frampton, Michael B
2016-07-11
When reporting research findings, scientists document the steps they followed so that others can verify and build upon the research. When those steps have been described in sufficient detail that others can retrace the steps and obtain similar results, the research is said to be reproducible. Computers play a vital role in many research disciplines and present both opportunities and challenges for reproducibility. Computers can be programmed to execute analysis tasks, and those programs can be repeated and shared with others. The deterministic nature of most computer programs means that the same analysis tasks, applied to the same data, will often produce the same outputs. However, in practice, computational findings often cannot be reproduced because of complexities in how software is packaged, installed, and executed-and because of limitations associated with how scientists document analysis steps. Many tools and techniques are available to help overcome these challenges; here we describe seven such strategies. With a broad scientific audience in mind, we describe the strengths and limitations of each approach, as well as the circumstances under which each might be applied. No single strategy is sufficient for every scenario; thus we emphasize that it is often useful to combine approaches.
Medvedofsky, Diego; Addetia, Karima; Patel, Amit R; Sedlmeier, Anke; Baumann, Rolf; Mor-Avi, Victor; Lang, Roberto M
2015-10-01
Echocardiographic assessment of the right ventricle is difficult because of its complex shape. Three-dimensional echocardiographic (3DE) imaging allows more accurate and reproducible analysis of the right ventricle than two-dimensional methodology. However, three-dimensional volumetric analysis has been hampered by difficulties obtaining consistently high-quality coronal views, required by the existing software packages. The aim of this study was to test a new approach for volumetric analysis without coronal views by using instead right ventricle-focused three-dimensional acquisition with multiple short-axis views extracted from the same data set. Transthoracic 3DE and cardiovascular magnetic resonance (CMR) images were prospectively obtained on the same day in 147 patients with wide ranges of right ventricular (RV) size and function. RV volumes and ejection fraction were measured from 3DE images using the new software and compared with CMR reference values. Comparisons included linear regression and Bland-Altman analyses. Repeated measurements were performed to assess measurement variability. Sixteen patients were excluded because of suboptimal image quality (89% feasibility). RV volumes and ejection fraction obtained with the new 3DE technique were in good agreement with CMR (end-diastolic volume, r = 0.95; end-systolic volume, r = 0.96; ejection fraction, r = 0.83). Biases were, respectively, -6 ± 11%, 0 ± 15%, and -7 ± 17% of the mean measured values. In a subset of patients with suboptimal 3DE images, the new analysis resulted in significantly improved accuracy against CMR and reproducibility, compared with previously used coronal view-based techniques. The time required for the 3DE analysis was approximately 4 min. The new software is fast, reproducible, and accurate compared with CMR over a wide range of RV size and function. Because right ventricle-focused 3DE acquisition is feasible in most patients, this approach may be applicable to a broader population of patients who can benefit from RV volumetric assessment. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Kloppenburg, W D; Wolthers, B G; Stellaard, F; Elzinga, H; Tepper, T; de Jong, P E; Huisman, R M
1997-07-01
1. Stable urea isotopes can be used to study urea kinetics in humans. The use of stable urea isotopes for studying urea kinetic parameters in humans on a large scale is hampered by the high costs of the labelled material. We devised a urea dilution for measurement of the distribution volume, production rate and clearance of urea in healthy subjects and renal failure patients using the inexpensive single labelled [13C]urea isotope with subsequent analysis by headspace chromatography-isotope ratio MS (GC-IRMS) of the [13C]urea enrichment. 2. The method involves measurement of the molar percentage excess of [13C]urea in plasma samples taken over a 4 h period after an intravenous bolus injection of [13C]urea. During the sample processing procedure, the plasma samples together with calibration samples containing a known molar percentage excess of [13C]urea are acidified with phosphoric acid to remove endogenous CO2, and are subsequently incubated with urease to convert the urea present in the plasma samples into CO2. The 13C enrichment of the generated CO2 is analysed by means of GC-IRMS. This method allows measurement of the molar percentage excess of [13C]urea to an accuracy of 0.02%. 3. Reproducibility studies showed that the sample processing procedure [within-run coefficient of variation (CV) < 2.8% and between-run CV < 8.8%] and the GC-IRMS analysis (within-day CV < 1.3% and between-day CV < 1.3%) could be repeated with good reproducibility. 4. In clinical urea kinetic studies in a healthy subject and in a renal failure patient without residual renal function, reproducible values of the distribution volume, production rate and clearance of urea were determined using minimal amounts of [13C]urea (25-50 mg). 5. Because only low [13C]urea enrichments are needed in this urea dilution method using GC-IRMS analysis, the costs of urea kinetic studies are reduced considerably, especially in patients with renal failure.
Armour, M.; Ford, E.; Iordachita, I.; Wong, J.
2011-01-01
To study the effects of cranial irradiation, we have constructed an all-plastic mouse bed equipped with an immobilizing head holder. The bed integrates with our in-house Small Animal Radiation Research Platform (SARRP) for precision focal irradiation experiments and cone-beam CT. We assessed the reproducibility of our head holder to determine the need for CT based targeting in cranial irradiation studies. To measure the holder’s reproducibility, a C57BL/6 mouse was positioned and CT scanned nine times. Image sets were loaded into the Pinnacle3 radiation treatment planning system and were registered to one another by one investigator using rigid body alignment of the cranial regions. Rotational and translational offsets were measured. The average vector shift between scans was 0.80 ± 0.49 mm. Such a shift is too large to selectively treat subregions of the mouse brain. In response, we use onboard imaging to guide cranial irradiation applications that require sub-millimeter precision. PMID:20041766
Reproducibility of WC-C High-Temperature Fixed Point
NASA Astrophysics Data System (ADS)
Grigoryeva, I. A.; Khlevnoy, B. B.; Solodilov, M. V.
2017-05-01
Reproducibility of the tungsten carbide-carbon peritectic (WC-C) fixed point (3021 K) was investigated by comparing six WC-C blackbody-type cells with each other. All the cells were built at VNIIOFI and had the same design with a cell outer diameter of 24 mm and a cavity opening diameter of 3 mm. Four cells were built using tungsten powder supplied by Alfa Aesar, while the other two cells used powder from Zhuzhou KETE (China). The nominal purity of both suppliers was 99.999 %. All the cells were compared in the same furnace. A reference cell in the second furnace was used for monitoring the stability of a radiation thermometer. Melting temperatures (given by the point of inflection) of all six cells agreed within ±45 mK. The reproducibility, as a standard deviation of the measured temperatures, can be estimated as 35 mK. The Zhuzhou KETE cells showed a slightly lower temperature than the Alfa Aesar cells: by 32 mK on average, which is comparable with repeatability of the measurements.
Ranking and averaging independent component analysis by reproducibility (RAICAR).
Yang, Zhi; LaConte, Stephen; Weng, Xuchu; Hu, Xiaoping
2008-06-01
Independent component analysis (ICA) is a data-driven approach that has exhibited great utility for functional magnetic resonance imaging (fMRI). Standard ICA implementations, however, do not provide the number and relative importance of the resulting components. In addition, ICA algorithms utilizing gradient-based optimization give decompositions that are dependent on initialization values, which can lead to dramatically different results. In this work, a new method, RAICAR (Ranking and Averaging Independent Component Analysis by Reproducibility), is introduced to address these issues for spatial ICA applied to fMRI. RAICAR utilizes repeated ICA realizations and relies on the reproducibility between them to rank and select components. Different realizations are aligned based on correlations, leading to aligned components. Each component is ranked and thresholded based on between-realization correlations. Furthermore, different realizations of each aligned component are selectively averaged to generate the final estimate of the given component. Reliability and accuracy of this method are demonstrated with both simulated and experimental fMRI data. Copyright 2007 Wiley-Liss, Inc.
Armour, M; Ford, E; Iordachita, I; Wong, J
2010-01-01
To study the effects of cranial irradiation, we have constructed an all-plastic mouse bed equipped with an immobilizing head holder. The bed integrates with our in-house Small Animal Radiation Research Platform (SARRP) for precision focal irradiation experiments and cone-beam CT. We assessed the reproducibility of our head holder to determine the need for CT-based targeting in cranial irradiation studies. To measure the holder's reproducibility, a C57BL/6 mouse was positioned and CT-scanned nine times. Image sets were loaded into the Pinnacle(3) radiation treatment planning system and were registered to one another by one investigator using rigid body alignment of the cranial regions. Rotational and translational offsets were measured. The average vector shift between scans was 0.80 +/- 0.49 mm. Such a shift is too large to selectively treat subregions of the mouse brain. In response, we use onboard imaging to guide cranial irradiation applications that require sub-millimeter precision.
A philosopher looks at assisted reproduction.
Steinbock, B
1995-09-01
The article first examines the various objections to IVF: religious, health and safety and feminist. It is argued that none of these objections provides good reasons for banning IVF, though certain controls and procedures to protect individuals from harm and exploitation may be appropriate. Next, the article critiques John Robertson's strong conception of procreative liberty, which entails a right to be a surrogate mother or serve as a sperm donor. Roberton's interpretation misconceives the nature and value of the right to reproduce. The righ to reproduce is best interpreted as a right to have one's own children to rear. Where there is no intent or ability to rear, there is no fundamental moral right to reproduce. However, since assisted reproduction is used to enable individuals to have their own children to rear, it should be available to infertile individuals who cannot otherwise reproduce.
Intra-session repeatability of lower limb muscles activation pattern during pedaling.
Dorel, Sylvain; Couturier, Antoine; Hug, François
2008-10-01
Assessment of intra-session repeatability of muscle activation pattern is of considerable relevance for research settings, especially when used to determine changes over time. However, the repeatability of lower limb muscles activation pattern during pedaling is not fully established. Thus, we tested the intra-session repeatability of the activation pattern of 10 lower limb muscles during a sub-maximal cycling exercise. Eleven triathletes participated to this study. The experimental session consisted in a reference sub-maximal cycling exercise (i.e. 150 W) performed before and after a 53-min simulated training session (mean power output=200+/-12 W). Repeatability of EMG patterns was assessed in terms of muscle activity level (i.e. RMS of the mean pedaling cycle and burst) and muscle activation timing (i.e. onset and offset of the EMG burst) for the 10 following lower limb muscles: gluteus maximus (GMax), semimembranosus (SM), Biceps femoris (BF), vastus medialis (VM), rectus femoris (RF), vastus lateralis (VL), gastrocnemius medianus (GM) and lateralis (GL), soleus (SOL) and tibialis anterior (TA). No significant differences concerning the muscle activation level were found between test and retest for all the muscles investigated. Only VM, SOL and TA showed significant differences in muscle activation timing parameters. Whereas ICC and SEM values confirmed this weak repeatability, cross-correlation coefficients suggest a good repeatability of the activation timing parameters for all the studied muscles. Overall, the main finding of this work is the good repeatability of the EMG pattern during pedaling both in term of muscle activity level and muscle activation timing.
Sequence repeats and protein structure
NASA Astrophysics Data System (ADS)
Hoang, Trinh X.; Trovato, Antonio; Seno, Flavio; Banavar, Jayanth R.; Maritan, Amos
2012-11-01
Repeats are frequently found in known protein sequences. The level of sequence conservation in tandem repeats correlates with their propensities to be intrinsically disordered. We employ a coarse-grained model of a protein with a two-letter amino acid alphabet, hydrophobic (H) and polar (P), to examine the sequence-structure relationship in the realm of repeated sequences. A fraction of repeated sequences comprises a distinct class of bad folders, whose folding temperatures are much lower than those of random sequences. Imperfection in sequence repetition improves the folding properties of the bad folders while deteriorating those of the good folders. Our results may explain why nature has utilized repeated sequences for their versatility and especially to design functional proteins that are intrinsically unstructured at physiological temperatures.
Culture: copying, compression, and conventionality.
Tamariz, Mónica; Kirby, Simon
2015-01-01
Through cultural transmission, repeated learning by new individuals transforms cultural information, which tends to become increasingly compressible (Kirby, Cornish, & Smith, ; Smith, Tamariz, & Kirby, ). Existing diffusion chain studies include in their design two processes that could be responsible for this tendency: learning (storing patterns in memory) and reproducing (producing the patterns again). This paper manipulates the presence of learning in a simple iterated drawing design experiment. We find that learning seems to be the causal factor behind the increase in compressibility observed in the transmitted information, while reproducing is a source of random heritable innovations. Only a theory invoking these two aspects of cultural learning will be able to explain human culture's fundamental balance between stability and innovation. Copyright © 2014 Cognitive Science Society, Inc.
Investigation of LiF, Mg and Ti (TLD-100) Reproducibility
Sadeghi, M.; Sina, S.; Faghihi, R.
2015-01-01
LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%. PMID:26688801
Investigation of LiF, Mg and Ti (TLD-100) Reproducibility.
Sadeghi, M; Sina, S; Faghihi, R
2015-12-01
LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.
Urinary incontinence self-report questions: reproducibility and agreement with bladder diary.
Bradley, Catherine S; Brown, Jeanette S; Van Den Eeden, Stephen K; Schembri, Michael; Ragins, Arona; Thom, David H
2011-12-01
This study aims to measure self-report urinary incontinence questions' reproducibility and agreement with bladder diary. Data were analyzed from the Reproductive Risk of Incontinence Study at Kaiser. Participating women reporting at least weekly incontinence completed self-report incontinence questions and a 7-day bladder diary. Self-report question reproducibility was assessed and agreement between self-reported and diary-recorded voiding and incontinence frequency was measured. Test characteristics and area under the curve were calculated for self-reported incontinence types using diary as the gold standard. Five hundred ninety-one women were included and 425 completed a diary. The self-report questions had moderate reproducibility and self-reported and diary-recorded incontinence and voiding frequencies had moderate to good agreement. Self-reported incontinence types identified stress and urgency incontinence more accurately than mixed incontinence. Self-report incontinence questions have moderate reproducibility and agreement with diary, and considering their minimal burden, are acceptable research tools in epidemiologic studies.
History, rare, and multiple events of mechanical unfolding of repeat proteins
NASA Astrophysics Data System (ADS)
Sumbul, Fidan; Marchesi, Arin; Rico, Felix
2018-03-01
Mechanical unfolding of proteins consisting of repeat domains is an excellent tool to obtain large statistics. Force spectroscopy experiments using atomic force microscopy on proteins presenting multiple domains have revealed that unfolding forces depend on the number of folded domains (history) and have reported intermediate states and rare events. However, the common use of unspecific attachment approaches to pull the protein of interest holds important limitations to study unfolding history and may lead to discarding rare and multiple probing events due to the presence of unspecific adhesion and uncertainty on the pulling site. Site-specific methods that have recently emerged minimize this uncertainty and would be excellent tools to probe unfolding history and rare events. However, detailed characterization of these approaches is required to identify their advantages and limitations. Here, we characterize a site-specific binding approach based on the ultrastable complex dockerin/cohesin III revealing its advantages and limitations to assess the unfolding history and to investigate rare and multiple events during the unfolding of repeated domains. We show that this approach is more robust, reproducible, and provides larger statistics than conventional unspecific methods. We show that the method is optimal to reveal the history of unfolding from the very first domain and to detect rare events, while being more limited to assess intermediate states. Finally, we quantify the forces required to unfold two molecules pulled in parallel, difficult when using unspecific approaches. The proposed method represents a step forward toward more reproducible measurements to probe protein unfolding history and opens the door to systematic probing of rare and multiple molecule unfolding mechanisms.
Consistency of blood pressure differences between the left and right arms.
Eguchi, Kazuo; Yacoub, Mona; Jhalani, Juhee; Gerin, William; Schwartz, Joseph E; Pickering, Thomas G
2007-02-26
It is unclear to what extent interarm blood pressure (BP) differences are reproducible vs the result of random error. The present study was designed to resolve this issue. We enrolled 147 consecutive patients from a hypertension clinic. Three sets of 3 BP readings were recorded, first using 2 oscillometric devices simultaneously in the 2 arms (set 1); next, 3 readings were taken sequentially for each arm using a standard mercury sphygmomanometer (set 2); finally, the readings as performed for set 1 were repeated (set 3). The protocol was repeated at a second visit for 91 patients. Large interarm systolic BP differences were consistently seen in 2 patients with obstructive arterial disease. In the remaining patients, the systolic BP and the diastolic BP, respectively, were slightly higher in the right arm than in the left arm by 2 to 3 mm Hg and by 1 mm Hg for all 3 sets (P<.01 for all). For the systolic BP and the diastolic BP, respectively, the numbers of patients who had a mean interarm difference of more than 5 mm Hg were 11 (7.5%) and 4 (2.7%) across all 3 sets of readings. Among patients who repeated the test, none had a consistent interarm BP difference of more than 5 mm Hg across the 2 visits. The interarm BP difference was consistent only when obstructive arterial disease was present. Although BP in the right arm tended to be higher than in the left arm, clinically meaningful interarm differences were not reproducible in the absence of obstructive arterial disease and are attributable to random variation.
Yang, Hyeri; Na, Jihye; Jang, Won-Hee; Jung, Mi-Sook; Jeon, Jun-Young; Heo, Yong; Yeo, Kyung-Wook; Jo, Ji-Hoon; Lim, Kyung-Min; Bae, SeungJin
2015-05-05
Mouse local lymph node assay (LLNA, OECD TG429) is an alternative test replacing conventional guinea pig tests (OECD TG406) for the skin sensitization test but the use of a radioisotopic agent, (3)H-thymidine, deters its active dissemination. New non-radioisotopic LLNA, LLNA:BrdU-FCM employs a non-radioisotopic analog, 5-bromo-2'-deoxyuridine (BrdU) and flow cytometry. For an analogous method, OECD TG429 performance standard (PS) advises that two reference compounds be tested repeatedly and ECt(threshold) values obtained must fall within acceptable ranges to prove within- and between-laboratory reproducibility. However, this criteria is somewhat arbitrary and sample size of ECt is less than 5, raising concerns about insufficient reliability. Here, we explored various statistical methods to evaluate the reproducibility of LLNA:BrdU-FCM with stimulation index (SI), the raw data for ECt calculation, produced from 3 laboratories. Descriptive statistics along with graphical representation of SI was presented. For inferential statistics, parametric and non-parametric methods were applied to test the reproducibility of SI of a concurrent positive control and the robustness of results were investigated. Descriptive statistics and graphical representation of SI alone could illustrate the within- and between-laboratory reproducibility. Inferential statistics employing parametric and nonparametric methods drew similar conclusion. While all labs passed within- and between-laboratory reproducibility criteria given by OECD TG429 PS based on ECt values, statistical evaluation based on SI values showed that only two labs succeeded in achieving within-laboratory reproducibility. For those two labs that satisfied the within-lab reproducibility, between-laboratory reproducibility could be also attained based on inferential as well as descriptive statistics. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Zhang, Jiming; Arena, Claudio; Pednekar, Amol; Lambert, Brenda; Dees, Debra; Lee, Vei Vei; Muthupillai, Raja
2016-03-01
Magnetic resonance elastography (MRE) can estimate liver stiffness (LS) noninvasively. We prospectively assessed whether motion-encoding gradient (MEG) direction, slice position, or high-caloric food intake affects the repeatability of MRE measurements of LS. Twenty healthy volunteers (8 women, 12 men; age, 48 ± 12 years) were imaged in a 3.0T scanner at four timepoints: twice after overnight fasting (B1 , B2 ) and twice after consuming a 1050-calorie standardized meal (A1 , A2 ; after 30 and 60 min, respectively). Each session comprised sequential MRE acquisitions in which MEG was applied in three orthogonal directions with three slices positioned over the liver for each. Between sessions, the participants were repositioned to assess test-retest reproducibility. The LS measurements before/after food intake were 3.36 ± 1.31 kPa/3.22 ± 1.03 kPa, 2.04 ± 0.33 kPa/2.27 ± 0.38 kPa, and 2.47 ± 0.50 kPa/2.64 ± 0.76 kPa for MEG superimposed along the anterior-posterior (AP), foot-head (FH), and right-left (RL) directions, respectively. Before and after food intake, LS estimates were lower and more reproducible (<10% coefficient of variation) when the MEG was in the FH direction, not the AP or RL direction. Liver stiffness estimates were significantly elevated after meal consumption when the MEG was in the FH direction (P < 0.05 for B1 vs. A1 , B1 vs. A2 , B2 vs. A1 , and B2 vs. A2 ). MRE estimates of LS were highly reproducible, particularly when MEG was applied in the FH direction, suggesting that this method could be used for long-term monitoring of antifibrotic therapy without repeated biopsies. High-caloric food intake resulted in slightly elevated LS on MRE. © 2015 Wiley Periodicals, Inc.
Repeated mild closed head injury impairs short-term visuospatial memory and complex learning.
Hylin, Michael J; Orsi, Sara A; Rozas, Natalia S; Hill, Julia L; Zhao, Jing; Redell, John B; Moore, Anthony N; Dash, Pramod K
2013-05-01
Concussive force can cause neurocognitive and neurobehavioral dysfunction by inducing functional, electrophysiological, and/or ultrastructural changes within the brain. Although concussion-triggered symptoms typically subside within days to weeks in most people, in 15%-20% of the cases, symptomology can continue beyond this time point. Problems with memory, attention, processing speed, and cognitive flexibility (e.g., problem solving, conflict resolution) are some of the prominent post-concussive cognitive symptoms. Repeated concussions (with loss or altered consciousness), which are common to many contact sports, can exacerbate these symptoms. The pathophysiology of repeated concussions is not well understood, nor is an effective treatment available. In order to facilitate drug discovery to treat post-concussive symptoms (PCSs), there is a need to determine if animal models of repeated mild closed head injury (mCHI) can mimic the neurocognitive and histopathological consequences of repeated concussions. To this end, we employed a controlled cortical impact (CCI) device to deliver a mCHI directly to the skull of mice daily for 4 days, and examined the ensuing neurological and neurocognitive functions using beam balance, foot-fault, an abbreviated Morris water maze test, context discrimination, and active place avoidance tasks. Repeated mCHI exacerbated vestibulomotor, motor, short-term memory and conflict learning impairments as compared to a single mCHI. Learning and memory impairments were still observed in repeated mCHI mice when tested 3 months post-injury. Repeated mCHI also reduced cerebral perfusion, prolonged the inflammatory response, and in some animals, caused hippocampal neuronal loss. Our results show that repeated mCHI can reproduce some of the deficits seen after repeated concussions in humans and may be suitable for drug discovery studies and translational research.
GeoTrust Hub: A Platform For Sharing And Reproducing Geoscience Applications
NASA Astrophysics Data System (ADS)
Malik, T.; Tarboton, D. G.; Goodall, J. L.; Choi, E.; Bhatt, A.; Peckham, S. D.; Foster, I.; Ton That, D. H.; Essawy, B.; Yuan, Z.; Dash, P. K.; Fils, G.; Gan, T.; Fadugba, O. I.; Saxena, A.; Valentic, T. A.
2017-12-01
Recent requirements of scholarly communication emphasize the reproducibility of scientific claims. Text-based research papers are considered poor mediums to establish reproducibility. Papers must be accompanied by "research objects", aggregation of digital artifacts that together with the paper provide an authoritative record of a piece of research. We will present GeoTrust Hub (http://geotrusthub.org), a platform for creating, sharing, and reproducing reusable research objects. GeoTrust Hub provides tools for scientists to create `geounits'--reusable research objects. Geounits are self-contained, annotated, and versioned containers that describe and package computational experiments in an efficient and light-weight manner. Geounits can be shared on public repositories such as HydroShare and FigShare, and also using their respective APIs reproduced on provisioned clouds. The latter feature enables science applications to have a lifetime beyond sharing, wherein they can be independently verified and trust be established as they are repeatedly reused. Through research use cases from several geoscience laboratories across the United States, we will demonstrate how tools provided from GeoTrust Hub along with Hydroshare as its public repository for geounits is advancing the state of reproducible research in the geosciences. For each use case, we will address different computational reproducibility requirements. Our first use case will be an example of setup reproducibility which enables a scientist to set up and reproduce an output from a model with complex configuration and development environments. Our second use case will be an example of algorithm/data reproducibility, where in a shared data science model/dataset can be substituted with an alternate one to verify model output results, and finally an example of interactive reproducibility, in which an experiment is dependent on specific versions of data to produce the result. Toward this we will use software and data used in preparing data for the MODFLOW model in Hydrology, JupyterHub used in Hydroshare, PyLith used in Computational Infrastructure for Geodynamics, and GeoSpace Collaborative Observations and Assimilative Modeling used in space science. The GeoTrust Hub is funded through the National Science Foundation EarthCube program.
Actinic cheilitis: proposition and reproducibility of a clinical criterion
Poitevin, Nádia Antunes; Rodrigues, Mariana Sudati; Weigert, Karen Loureiro; Macedo, Carmen Lúcia Rodrigues; dos Santos, Rubem Beraldo
2017-01-01
Objectives/Aims: The actinic cheilitis (AC) is a precancerous lip lesion seen as a consequence of chronic sun exposure. Clinically, the border between the lip’s skin and the semimucosa could be blurred; in the more aggressive cases, leucoplakia and ulcers also represent its clinical feature. It seems that no clinical criterion is universally accepted for this disease yet. Therefore, this study was carried out to make a proposition of a clinical score to actinic cheilitis (Grade I starting from dryness of vermilion to endured ulcers representing Grade IV) and to assess its reproducibility. Materials and Methods: Fifty subjects were assessed, most of whom were male, Caucasian farmers, with an average age of 46.12 (18–74) years. The obtained data were analysed by means of descriptive statistics and by Kappa test to assess the inter-examiners and the clinical Golden-Pattern concordance (95% CI). Results: During calibration, 15 patients were examined three times a week by each examiner (4) until Kappa test observed k=0.8 or more. In the main experiment, the inter-examiner concordance was classified between good (k=0.779; P<0.05) and very good (k=0.925; P<0.05) from the 35 examined subjects. With the Golden-Pattern, it was considered very good (k=0.812; P<0.05 to k=0.925; P<0.05). Discussion: Four examiners with different experiences could strongly suggest that after adequate calibration, it could be well applied by examiners with as much experience as a dental student. Conclusions: The authors concluded that the proposed classification was easily applied and had a very good reproducibility. PMID:29607086
Elson, D W; Jones, S; Caplan, N; Stewart, S; St Clair Gibson, A; Kader, D F
2011-12-01
Pain maps are used to determine the location of pain. Knee pain maps have previously been described, but only one study has reported on reliability and none report validity. The present study describes the generation of a photographic knee pain map (PKPM) together with its validity and reliability. A photographic representation of a pair of knees was chosen by 26 patients, (66.7%) from a group of 39. The selected photograph was modified and a template of anatomical zones was generated. The opinions of 25 independent subject matter experts were canvassed and validity ratios calculated for these zones, ranged from 0.28 to 0.84. Hypothetical comparisons were made between the PKPM and an alternative knee pain map, in a cross-sectional group of 26 patients (35 knees). Convergent patterns of validity were found where hypothesised. Reliability was determined using a different cohort of 44 patients (58 knees) who completed the PKPM before and after a sampling delay. Four of these patients were excluded with a short sampling delay. Calculated agreement of test-retest reproducibility was fair to good. All of the completed PKPM (151 knees) were then subject to further analysis where inter-rater reproducibility was good to very good and intra-rater reproducibility was very good. The PKPM is readily accessible to patients with low completion burden. It is both valid and reliable and we suggest it can be used in both clinical and research settings. Further studies are planned to explore its predictive ability as a diagnostic tool. The PKPM can be found at www.photographickneepainmap.com. Copyright © 2010 Elsevier B.V. All rights reserved.
O'Keeffe, S T; Lye, M; Donnellan, C; Carmichael, D N
1998-10-01
To examine the reproducibility and responsiveness to change of a six minute walk test and a quality of life measure in elderly patients with heart failure. Longitudinal within patient study. 60 patients with heart failure (mean age 82 years) attending a geriatric outpatient clinic, 45 of whom underwent a repeat assessment three to eight weeks later. Subjects underwent a standardised six minute walk test and completed the chronic heart failure questionnaire (CHQ), a heart failure specific quality of life questionnaire. Intraclass correlation coefficients (ICC) were calculated using a random effects one way analysis of variance as a measure of reproducibility. Guyatt's responsiveness coefficient and effect sizes were calculated as measures of responsiveness to change. 24 patients reported no major change in cardiac status, while seven had deteriorated and 14 had improved between the two clinic visits. Reproducibility was satisfactory (ICC > 0.75) for the six minute walk test, for the total CHQ score, and for the dyspnoea, fatigue, and emotion domains of the CHQ. Effect sizes for all measures were large (> 0.8), and responsiveness coefficients were very satisfactory (> 0.7). Effect sizes for detecting deterioration were greater than those for detecting improvement. Quality of life assessment and a six minute walk test are reproducible and responsive measures of cardiac status in frail, very elderly patients with heart failure.
Nakratzas, G.; Wagenaar, J. P. M.; Reintjes, M.; Scheffer, E.; Swierenga, J.
1974-01-01
Nakratzas, G., Wagenaar, J. P. M., Reintjes, M., Scheffer, E., and Swierenga, J. (1974).Thorax, 29, 125-131. Repeated partial endoscopic resections as treatment for two patients with inoperable tracheal tumours. Two cases of tracheal tumour are described, one a carcinoid and the other an adenoid cystic carcinoma (cylindroma). Both patients were treated by repeated partial bronchoscopic resections. The patients are in good health nine and three years respectively after treatment. Images PMID:4363463
2013-01-01
Background Hybridogenesis (hemiclonal inheritance) is a kind of clonal reproduction in which hybrids between parental species are reproduced by crossing with one of the parental species. European water frogs (Pelophylax esculentus complex) represent an appropriate model for studying interspecies hybridization, processes of hemiclonal inheritance and polyploidization. P. esculentus complex consists of two parental species, P. ridibundus (the lake frog) and P. lessonae (the pool frog), and their hybridogenetic hybrid – P. esculentus (the edible frog). Parental and hybrid frogs can reproduce syntopically and form hemiclonal population systems. For studying mechanisms underlying the maintenance of water frog population systems it is required to characterize the karyotypes transmitted in gametes of parental and different hybrid animals of both sexes. Results In order to obtain an instrument for characterization of oocyte karyotypes in hybrid female frogs, we constructed cytological maps of lampbrush chromosomes from oocytes of both parental species originating in Eastern Ukraine. We further identified certain molecular components of chromosomal marker structures and mapped coilin-rich spheres and granules, chromosome associated nucleoli and special loops accumulating splicing factors. We recorded the dissimilarities between P. ridibundus and P. lessonae lampbrush chromosomes in the length of orthologous chromosomes, number and location of marker structures and interstitial (TTAGGG)n-repeat sites as well as activity of nucleolus organizer. Satellite repeat RrS1 was mapped in centromere regions of lampbrush chromosomes of the both species. Additionally, we discovered transcripts of RrS1 repeat in oocytes of P. ridibundus and P. lessonae. Moreover, G-rich transcripts of telomere repeat were revealed in association with terminal regions of P. ridibundus and P. lessonae lampbrush chromosomes. Conclusions The constructed cytological maps of lampbrush chromosomes of P. ridibundus and P. lessonae provide basis to define the type of genome transmitted within individual oocytes of P. esculentus females with different ploidy and from various population systems. PMID:23590698
Inter-method Performance Study of Tumor Volumetry Assessment on Computed Tomography Test-retest Data
Buckler, Andrew J.; Danagoulian, Jovanna; Johnson, Kjell; Peskin, Adele; Gavrielides, Marios A.; Petrick, Nicholas; Obuchowski, Nancy A.; Beaumont, Hubert; Hadjiiski, Lubomir; Jarecha, Rudresh; Kuhnigk, Jan-Martin; Mantri, Ninad; McNitt-Gray, Michael; Moltz, Jan Hendrik; Nyiri, Gergely; Peterson, Sam; Tervé, Pierre; Tietjen, Christian; von Lavante, Etienne; Ma, Xiaonan; Pierre, Samantha St.; Athelogou, Maria
2015-01-01
Rationale and objectives Tumor volume change has potential as a biomarker for diagnosis, therapy planning, and treatment response. Precision was evaluated and compared among semi-automated lung tumor volume measurement algorithms from clinical thoracic CT datasets. The results inform approaches and testing requirements for establishing conformance with the Quantitative Imaging Biomarker Alliance (QIBA) CT Volumetry Profile. Materials and Methods Industry and academic groups participated in a challenge study. Intra-algorithm repeatability and inter-algorithm reproducibility were estimated. Relative magnitudes of various sources of variability were estimated using a linear mixed effects model. Segmentation boundaries were compared to provide a basis on which to optimize algorithm performance for developers. Results Intra-algorithm repeatability ranged from 13% (best performing) to 100% (least performing), with most algorithms demonstrating improved repeatability as the tumor size increased. Inter-algorithm reproducibility determined in three partitions and found to be 58% for the four best performing groups, 70% for the set of groups meeting repeatability requirements, and 84% when all groups but the least performer were included. The best performing partition performed markedly better on tumors with equivalent diameters above 40 mm. Larger tumors benefitted by human editing but smaller tumors did not. One-fifth to one-half of the total variability came from sources independent of the algorithms. Segmentation boundaries differed substantially, not just in overall volume but in detail. Conclusions Nine of the twelve participating algorithms pass precision requirements similar to what is indicated in the QIBA Profile, with the caveat that the current study was not designed to explicitly evaluate algorithm Profile conformance. Change in tumor volume can be measured with confidence to within ±14% using any of these nine algorithms on tumor sizes above 10 mm. No partition of the algorithms were able to meet the QIBA requirements for interchangeability down to 10 mm, though the partition comprised of the best performing algorithms did meet this requirement above a tumor size of approximately 40 mm. PMID:26376841
Erdemir, Ahmet; Guess, Trent M.; Halloran, Jason P.; Modenese, Luca; Reinbolt, Jeffrey A.; Thelen, Darryl G.; Umberger, Brian R.
2016-01-01
Objective The overall goal of this document is to demonstrate that dissemination of models and analyses for assessing the reproducibility of simulation results can be incorporated in the scientific review process in biomechanics. Methods As part of a special issue on model sharing and reproducibility in IEEE Transactions on Biomedical Engineering, two manuscripts on computational biomechanics were submitted: A. Rajagopal et al., IEEE Trans. Biomed. Eng., 2016 and A. Schmitz and D. Piovesan, IEEE Trans. Biomed. Eng., 2016. Models used in these studies were shared with the scientific reviewers and the public. In addition to the standard review of the manuscripts, the reviewers downloaded the models and performed simulations that reproduced results reported in the studies. Results There was general agreement between simulation results of the authors and those of the reviewers. Discrepancies were resolved during the necessary revisions. The manuscripts and instructions for download and simulation were updated in response to the reviewers’ feedback; changes that may otherwise have been missed if explicit model sharing and simulation reproducibility analysis were not conducted in the review process. Increased burden on the authors and the reviewers, to facilitate model sharing and to repeat simulations, were noted. Conclusion When the authors of computational biomechanics studies provide access to models and data, the scientific reviewers can download and thoroughly explore the model, perform simulations, and evaluate simulation reproducibility beyond the traditional manuscript-only review process. Significance Model sharing and reproducibility analysis in scholarly publishing will result in a more rigorous review process, which will enhance the quality of modeling and simulation studies and inform future users of computational models. PMID:28072567
Jann, Johann-Christoph; Nowak, Daniel; Nolte, Florian; Fey, Stephanie; Nowak, Verena; Obländer, Julia; Pressler, Jovita; Palme, Iris; Xanthopoulos, Christina; Fabarius, Alice; Platzbecker, Uwe; Giagounidis, Aristoteles; Götze, Katharina; Letsch, Anne; Haase, Detlef; Schlenk, Richard; Bug, Gesine; Lübbert, Michael; Ganser, Arnold; Germing, Ulrich; Haferlach, Claudia; Hofmann, Wolf-Karsten; Mossner, Maximilian
2017-09-01
Cytogenetic aberrations such as deletion of chromosome 5q (del(5q)) represent key elements in routine clinical diagnostics of haematological malignancies. Currently established methods such as metaphase cytogenetics, FISH or array-based approaches have limitations due to their dependency on viable cells, high costs or semi-quantitative nature. Importantly, they cannot be used on low abundance DNA. We therefore aimed to establish a robust and quantitative technique that overcomes these shortcomings. For precise determination of del(5q) cell fractions, we developed an inexpensive multiplex-PCR assay requiring only nanograms of DNA that simultaneously measures allelic imbalances of 12 independent short tandem repeat markers. Application of this method to n=1142 samples from n=260 individuals revealed strong intermarker concordance (R²=0.77-0.97) and reproducibility (mean SD: 1.7%). Notably, the assay showed accurate quantification via standard curve assessment (R²>0.99) and high concordance with paired FISH measurements (R²=0.92) even with subnanogram amounts of DNA. Moreover, cytogenetic response was reliably confirmed in del(5q) patients with myelodysplastic syndromes treated with lenalidomide. While the assay demonstrated good diagnostic accuracy in receiver operating characteristic analysis (area under the curve: 0.97), we further observed robust correlation between bone marrow and peripheral blood samples (R²=0.79), suggesting its potential suitability for less-invasive clonal monitoring. In conclusion, we present an adaptable tool for quantification of chromosomal aberrations, particularly in problematic samples, which should be easily applicable to further tumour entities. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Vu, Kim-Nhien; Gilbert, Guillaume; Chalut, Marianne; Chagnon, Miguel; Chartrand, Gabriel; Tang, An
2016-05-01
To assess the agreement between published magnetic resonance imaging (MRI)-based regions of interest (ROI) sampling methods using liver mean proton density fat fraction (PDFF) as the reference standard. This retrospective, internal review board-approved study was conducted in 35 patients with type 2 diabetes. Liver PDFF was measured by magnetic resonance spectroscopy (MRS) using a stimulated-echo acquisition mode sequence and MRI using a multiecho spoiled gradient-recalled echo sequence at 3.0T. ROI sampling methods reported in the literature were reproduced and liver mean PDFF obtained by whole-liver segmentation was used as the reference standard. Intraclass correlation coefficients (ICCs), Bland-Altman analysis, repeated-measures analysis of variance (ANOVA), and paired t-tests were performed. ICC between MRS and MRI-PDFF was 0.916. Bland-Altman analysis showed excellent intermethod agreement with a bias of -1.5 ± 2.8%. The repeated-measures ANOVA found no systematic variation of PDFF among the nine liver segments. The correlation between liver mean PDFF and ROI sampling methods was very good to excellent (0.873 to 0.975). Paired t-tests revealed significant differences (P < 0.05) with ROI sampling methods that exclusively or predominantly sampled the right lobe. Significant correlations with mean PDFF were found with sampling methods that included higher number of segments, total area equal or larger than 5 cm(2) , or sampled both lobes (P = 0.001, 0.023, and 0.002, respectively). MRI-PDFF quantification methods should sample each liver segment in both lobes and include a total surface area equal or larger than 5 cm(2) to provide a close estimate of the liver mean PDFF. © 2015 Wiley Periodicals, Inc.
T2 values of articular cartilage in clinically relevant subregions of the asymptomatic knee.
Surowiec, Rachel K; Lucas, Erin P; Fitzcharles, Eric K; Petre, Benjamin M; Dornan, Grant J; Giphart, J Erik; LaPrade, Robert F; Ho, Charles P
2014-06-01
In order for T2 mapping to become more clinically applicable, reproducible subregions and standardized T2 parameters must be defined. This study sought to: (1) define clinically relevant subregions of knee cartilage using bone landmarks identifiable on both MR images and during arthroscopy and (2) determine healthy T2 values and T2 texture parameters within these subregions. Twenty-five asymptomatic volunteers (age 18-35) were evaluated with a sagittal T2 mapping sequence. Manual segmentation was performed by three raters, and cartilage was divided into twenty-one subregions modified from the International Cartilage Repair Society Articular Cartilage Mapping System. Mean T2 values and texture parameters (entropy, variance, contrast, homogeneity) were recorded for each subregion, and inter-rater and intra-rater reliability was assessed. The central regions of the condyles had significantly higher T2 values than the posterior regions (P < 0.05) and higher variance than the posterior region on the medial side (P < 0.001). The central trochlea had significantly greater T2 values than the anterior and posterior condyles. The central lateral plateau had lower T2 values, lower variance, higher homogeneity, and lower contrast than nearly all subregions in the tibia. The central patellar regions had higher entropy than the superior and inferior regions (each P ≤ 0.001). Repeatability was good to excellent for all subregions. Significant differences in mean T2 values and texture parameters were found between subregions in this carefully selected asymptomatic population, which suggest that there is normal variation of T2 values within the knee joint. The clinically relevant subregions were found to be robust as demonstrated by the overall high repeatability.
Orthogonal Comparison of GC-MS and 1H NMR Spectroscopy for Short Chain Fatty Acid Quantitation.
Cai, Jingwei; Zhang, Jingtao; Tian, Yuan; Zhang, Limin; Hatzakis, Emmanuel; Krausz, Kristopher W; Smith, Philip B; Gonzalez, Frank J; Patterson, Andrew D
2017-08-01
Short chain fatty acids (SCFAs) are important regulators of host physiology and metabolism and may contribute to obesity and associated metabolic diseases. Interest in SCFAs has increased in part due to the recognized importance of how production of SCFAs by the microbiota may signal to the host. Therefore, reliable, reproducible, and affordable methods for SCFA profiling are required for accurate identification and quantitation. In the current study, four different methods for SCFA (acetic acid, propionic acid, and butyric acid) extraction and quantitation were compared using two independent platforms including gas chromatography coupled with mass spectrometry (GC-MS) and 1 H nuclear magnetic resonance (NMR) spectroscopy. Sensitivity, recovery, repeatability, matrix effect, and validation using mouse fecal samples were determined across all methods. The GC-MS propyl esterification method exhibited superior sensitivity for acetic acid and butyric acid measurement (LOD < 0.01 μg mL -1 , LOQ < 0.1 μg mL -1 ) and recovery accuracy (99.4%-108.3% recovery rate for 100 μg mL -1 SCFA mixed standard spike in and 97.8%-101.8% recovery rate for 250 μg mL -1 SCFAs mixed standard spike in). NMR methods by either quantitation relative to an internal standard or quantitation using a calibration curve yielded better repeatability and minimal matrix effects compared to GC-MS methods. All methods generated good calibration curve linearity (R 2 > 0.99) and comparable measurement of fecal SCFA concentration. Lastly, these methods were used to quantitate fecal SCFAs obtained from conventionally raised (CONV-R) and germ free (GF) mice. Results from global metabolomic analysis of feces generated by 1 H NMR and bomb calorimetry were used to further validate these approaches.
Otis, Colombe; Gervais, Julie; Guillot, Martin; Gervais, Julie-Anne; Gauvin, Dominique; Péthel, Catherine; Authier, Simon; Dansereau, Marc-André; Sarret, Philippe; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Beaudry, Francis; Troncy, Eric
2016-06-23
Lack of validity in osteoarthritis pain models and assessment methods is suspected. Our goal was to 1) assess the repeatability and reproducibility of measurement and the influence of environment, and acclimatization, to different pain assessment outcomes in normal rats, and 2) test the concurrent validity of the most reliable methods in relation to the expression of different spinal neuropeptides in a chemical model of osteoarthritic pain. Repeatability and inter-rater reliability of reflexive nociceptive mechanical thresholds, spontaneous static weight-bearing, treadmill, rotarod, and operant place escape/avoidance paradigm (PEAP) were assessed by the intraclass correlation coefficient (ICC). The most reliable acclimatization protocol was determined by comparing coefficients of variation. In a pilot comparative study, the sensitivity and responsiveness to treatment of the most reliable methods were tested in the monosodium iodoacetate (MIA) model over 21 days. Two MIA (2 mg) groups (including one lidocaine treatment group) and one sham group (0.9 % saline) received an intra-articular (50 μL) injection. No effect of environment (observer, inverted circadian cycle, or exercise) was observed; all tested methods except mechanical sensitivity (ICC <0.3), offered good repeatability (ICC ≥0.7). The most reliable acclimatization protocol included five assessments over two weeks. MIA-related osteoarthritic change in pain was demonstrated with static weight-bearing, punctate tactile allodynia evaluation, treadmill exercise and operant PEAP, the latter being the most responsive to analgesic intra-articular lidocaine. Substance P and calcitonin gene-related peptide were higher in MIA groups compared to naive (adjusted P (adj-P) = 0.016) or sham-treated (adj-P = 0.029) rats. Repeated post-MIA lidocaine injection resulted in 34 times lower downregulation for spinal substance P compared to MIA alone (adj-P = 0.029), with a concomitant increase of 17 % in time spent on the PEAP dark side (indicative of increased comfort). This study of normal rats and rats with pain established the most reliable and sensitive pain assessment methods and an optimized acclimatization protocol. Operant PEAP testing was more responsive to lidocaine analgesia than other tests used, while neuropeptide spinal concentration is an objective quantification method attractive to support and validate different centralized pain functional assessment methods.
Cikirikcioglu, Mustafa; Cikirikcioglu, Y Banu; Khabiri, Ebrahim; Djebaili, M Karim; Kalangos, Afksendiyos; Walpoth, Beat H
2006-01-01
Intra-operative flow measurement during coronary or peripheral bypass operations is helpful for ruling out technical failures and for prediction of complication and patency rates. Preclinical validation of the flowmeters is required in order to rely on the intra-operatively measured results. The aim of this study is to evaluate a new "dual beam Doppler" blood flowmeter before clinical application and to compare it with the established "transit time flow measure-ment" technique in an artificial circuit. Measurements were performed in an experimental flow model using pig blood and pig arteries. Three different flowmeters were used: Quantix OR (dual beam doppler flowmeter), CardioMed (transit time flowmeter), and Transonic (transit time flowmeter). Three validation tests were performed to assess correlation, precision, and repeatability of devices. (1) Correlation and agreement analysis was performed with various flow amounts (10-350 mL/min) (n = 160). (2) Device reproducibility and measurement stability were tested with a constant flow (flow amount = 300 mL/min) (n = 30). (3) A user accuracy test (intra- and inter-observer variability) was performed by 5 different observers with a constant flow (flow amount = 205 mL/min) (n = 75). Time collected true flow was used as a reference method in all steps and all tests were performed in a blind manner. Results are shown as mean values +/- standard deviations. Pear-son's correlation and Bland-Altman plot analyses were used to compare measurements. The mean flow was 167 +/- 98 mL/min for true flow and 162 +/- 94 mL/min, 165 +/- 94 mL/min, and 166 +/- 100 mL/min for Quantix OR, CardioMed, and Transonic, respectively. Correlation coefficients between Quantix OR, Medi-Stim, Transonic, and time collected true flow were over 0.98 (P = .01). Most of the measured results ( > 90%) were between +/- 1.96 SD agreement limits in Bland and Altman plot analysis. All devices showed good results in the reproducibility test. During the user accuracy test, larger variance changes were observed between intra- and inter-observer results with the dual beam Doppler flowmeter compared to the 2 used transit time flowmeters when used for single sided vessel access without stabilization device (available from the manufacturer). All 3 tested flowmeters showed an excellent correlation to the true flow in an artificial circuit and the accuracy of the tested devices was within agreement limits. Reproducibility of all devices was good and linear. The new dual beam Doppler flow measurement technique compares favorably to the classic transit time method. Clinical use may depend on operator, location, and condition, thus more studies may be required to ensure uniform results using the currently available blood flow measurement devices.
Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan
2014-01-01
Objective This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. Results The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models. PMID:24696823
Sadri, Minoo; Vatani, Hossein
2017-02-01
An ionic liquid-mediated multi-walled carbon nanotube (MWCNT)-polydimethylsiloxane (PDMS) sorbent was developed for headspace solid-phase microextraction (HS-SPME) of phenolic compounds from human urine samples. Sol-gel method was used to prepare this sorbent. For this purpose, MWCNTs were functionalized covalently and were attached chemically to the hydroxyl-terminated PDMS. Prepared fiber showed high thermal stability (over than 320°C) and good lifespan (>210 times). These good performances can be attributed to the performance of carbon nanotubes and sol-gel method. Affecting parameters on the efficiency of HS-SPME were investigated and optimized. Under the optimal conditions, linear dynamic ranges were observed over a range of 0.002-200 ng mL -1 with limits of detection from 0.0005 to 0.005 ng mL -1 and limits of quantitation between 0.002 and 0.02 ng mL -1 The relative standard deviations for one fiber (repeatability) (n = 5) at three different concentrations (0.05, 2 and 100 ng mL -1 ) were obtained from 4.6 up to 6.7% and between fibers or batch to batch (n = 3) (reproducibility) in the range of 5.7-7.8%. Urine samples were used as real samples. All real samples were spiked at 0.5 ng mL -1 of understudy analytes and the relative recovery percentages obtained from 90.7 to 102.1%. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Kausaite-Minkstimiene, Asta; Simanaityte, Ruta; Ramanaviciene, Almira; Glumbokaite, Laura; Ramanavicius, Arunas
2017-08-15
A reagent-less amperometric glucose biosensor operating in not-stirred sample solution was developed. A working electrode of the designed biosensor was based on a graphite rod (GR) electrode, which was modified with 1,10-phenanthroline-5,6-dione (PD) and glucose oxidase (GOx). The PD and the GOx were layer-by-layer adsorbed on the GR electrode surface with subsequent drying followed by chemical cross-linking of the adsorbed GOx with glutaraldehyde (GA). Optimal preparation conditions of the working electrode (GR/PD/GOx) were achieved with 12.6μg and 0.24mg loading amount of PD and GOx, respectively and 25min lasting cross-linking of the GOx with GA. A current response to glucose of the GR/PD/GOx electrode was measured at +200mV potential vs Ag/AgCl reference electrode. Maximum current response was registered when the pH of the buffer solution was 6.0. The registered current response to glucose was linear in the concentration range of 0.1-76mmolL -1 (R 2 =0.9985) and a detection limit was 0.025mmolL -1 . The GR/PD/GOx electrode demonstrated good reproducibility and repeatability with the relative standard deviation of 6.2% and 1.8% (at 4.0mmolL -1 of glucose), respectively, high anti-interference ability to uric and ascorbic acids. It was highly selective to glucose and demonstrated good accuracy in the analysis of human serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.
The long-term reliability of static and dynamic quantitative sensory testing in healthy individuals.
Marcuzzi, Anna; Wrigley, Paul J; Dean, Catherine M; Adams, Roger; Hush, Julia M
2017-07-01
Quantitative sensory tests (QSTs) have been increasingly used to investigate alterations in somatosensory function in a wide range of painful conditions. The interpretation of these findings is based on the assumption that the measures are stable and reproducible. To date, reliability of QST has been investigated for short test-retest intervals. The aim of this study was to investigate the long-term reliability of a multimodal QST assessment in healthy people, with testing conducted on 3 occasions over 4 months. Forty-two healthy people were enrolled in the study. Static and dynamic tests were performed, including cold and heat pain threshold (CPT, HPT), mechanical wind-up [wind-up ratio (WUR)], pressure pain threshold (PPT), 2-point discrimination (TPD), and conditioned pain modulation (CPM). Systematic bias, relative reliability and agreement were analysed using repeated measure analysis of variance, intraclass correlation coefficients (ICCs3,1) and SE of the measurement (SEM), respectively. Static QST (CPT, HPT, PPT, and TPD) showed good-to-excellent reliability (ICCs: 0.68-0.90). Dynamic QST (WUR and CPM) showed poor-to-good reliability (ICCs: 0.35-0.61). A significant linear decrease over time was observed for mechanical QST at the back (PPT and TPD) and for CPM (P < 0.01). Static QST were stable over a period of 4 months; however, a small systematic decrease over time has been observed for mechanical QST. Dynamic QST showed considerable variability over time; in particular, CPM using PPT as the test stimulus did not show adequate reliability, suggesting that this test paradigm may be less useful for monitoring individuals over time.
Luetzkendorf, Jana; Nerger, Katrin; Hering, Julian; Moegel, Angelika; Hoffmann, Katrin; Hoefers, Christiane; Mueller-Tidow, Carsten; Mueller, Lutz P
2015-02-01
The immunomodulating capacity of multipotent mesenchymal stromal cells (MSCs) qualifies them as a therapeutic tool in several diseases. However, repeated transplantation with products of reproducible characteristics may be required. This could be achieved with cryopreserved aliquots of Good Manufacturing Practice (GMP)-grade MSCs. However, the impact of cryopreservation on the characteristics of GMP-MSCs is ill defined. We produced fresh and cryopreserved MSCs from human donors with a xenogen-free GMP protocol. Immunogenicity and immunomodulating capacity were tested in co-culture with putative recipient-specific peripheral blood mononuclear cells (PBMCs). Risk of malignant transformation was assessed in vitro and in vivo. Cryopreservation had no impact on viability and consensus criteria of MSCs. In co-culture with PBMCs, MSCs showed low immunogenicity and suppressed mitogen-stimulated proliferation of PBMC irrespective of cryopreservation. Cytogenetic aberrations were not observed consistently in fresh and cryopreserved products, and no signs of malignant transformation occurred in functional assays. MSC products from an elderly pretreated donor showed reduced functional quality, but imminent failure of functional criteria could be detected by an increased population doubling time in early passages. This study is the first systematic analysis on cryopreservation of xenogen-free human bone marrow-derived GMP-MSCs. The data support that cryopreservation does not alter the characteristics of the cells and thus may allow the generation of products for serial transplantation. In addition, the protocol allowed early detection of MSC products with low functional capacity. Copyright © 2015 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
Validation of Fourier analysis of videokeratographic data.
Sideroudi, Haris; Labiris, Georgios; Ditzel, Fienke; Tsaragli, Efi; Georgatzoglou, Kimonas; Siganos, Haralampos; Kozobolis, Vassilios
2017-06-15
The aim was to assess the repeatability of Fourier transfom analysis of videokeratographic data using Pentacam in normal (CG), keratoconic (KC) and post-CXL (CXL) corneas. This was a prospective, clinic-based, observational study. One randomly selected eye from all study participants was included in the analysis: 62 normal eyes (CG group), 33 keratoconus eyes (KC group), while 34 eyes, which had already received CXL treatment, formed the CXL group. Fourier analysis of keratometric data were obtained using Pentacam, by two different operators within each of two sessions. Precision, repeatability and Intraclass Correlation Coefficient (ICC), were calculated for evaluating intrassesion and intersession repeatability for the following parameters: Spherical Component (SphRmin, SphEcc), Maximum Decentration (Max Dec), Regular Astigmatism, and Irregularitiy (Irr). Bland-Altman analysis was used for assessing interobserver repeatability. All parameters were presented to be repeatable, reliable and reproductible in all groups. Best intrasession and intersession repeatability and reliability were detected for parameters SphRmin, SphEcc and Max Dec parameters for both operators using ICC (intrasession: ICC > 98%, intersession: ICC > 94.7%) and within subject standard deviation. Best precision and lowest range of agreement was found for the SphRmin parameter (CG: 0.05, KC: 0.16, and CXL: 0.2) in all groups, while the lowest repeatability, reliability and reproducibility was detected for the Irr parameter. The Pentacam system provides accurate measurements of Fourier tranform keratometric data. A single Pentacam scan will be sufficient for most clinical applications.
[Standard sample preparation method for quick determination of trace elements in plastic].
Yao, Wen-Qing; Zong, Rui-Long; Zhu, Yong-Fa
2011-08-01
Reference sample was prepared by masterbatch method, containing heavy metals with known concentration of electronic information products (plastic), the repeatability and precision were determined, and reference sample preparation procedures were established. X-Ray fluorescence spectroscopy (XRF) analysis method was used to determine the repeatability and uncertainty in the analysis of the sample of heavy metals and bromine element. The working curve and the metrical methods for the reference sample were carried out. The results showed that the use of the method in the 200-2000 mg x kg(-1) concentration range for Hg, Pb, Cr and Br elements, and in the 20-200 mg x kg(-1) range for Cd elements, exhibited a very good linear relationship, and the repeatability of analysis methods for six times is good. In testing the circuit board ICB288G and ICB288 from the Mitsubishi Heavy Industry Company, results agreed with the recommended values.
[Validity and reproducibility of Escala de Evaluación da Insatisfación Corporal para Adolescentes].
Conti, Maria Aparecida; Slater, Betzabeth; Latorre, Maria do Rosário Dias de Oliveira
2009-06-01
To validate a body dissatisfaction scale for adolescents. The study included 386 female and male adolescents aged 10 to 17 years enrolled in a private elementary and middle school in the city of São Bernardo do Campo, southeastern Brazil, in 2006. 'Escala de Evaluación da Insatisfación Corporal para Adolescentes' (body dissatisfaction scale for adolescents) was translated and culturally adapted. The Portuguese instrument was evaluated for internal consistency using Cronbach's alpha, factor analysis with Varimax rotation, discriminant validity by comparing score means according to nutritional status (low weight, normal weight, and at risk of overweight and obesity) using the Kruskal-Wallis test. Concurrent validity was assessed using Spearman's rank correlation coefficient between scores and body mass index, waist-hip ratio and waist circumference. Reproducibility was evaluated using Wilcoxon test, and intraclass correlation coefficient. The translated and back-translated scale showed good agreement with the original one. The translated scale had good internal consistency in all subgroups studied (males and females in early and intermediate adolescence) and was able to discriminate adolescents according to their nutritional status. In the concurrent analysis, all three measures were correlated, except for males in early adolescence. Its reproducibility was ascertained. The 'Escala de Evaluación da Insatisfación Corporal para Adolescentes' was successfully translated into Portuguese and adapted to the Brazilian background and showed good results. It is recommended for the evaluation of the attitudinal component of body image in adolescents.
Shi, Changzheng; Zhang, Dong; Xiao, Zeyu; Wang, Li; Ma, Rong; Chen, Hanwei; Luo, Liangping
2017-09-01
To investigate the reproducibility of diffusion-weighted imaging (DWI) with ultrahigh b-values, and analyze the age-related differences in normal prostates. In all, 67 healthy participants were divided into three age groups (group A, 15-30 years; group B, 31-50 years; group C, ≥51 years), and underwent DWI scanning twice with 15 b-factors from 0 to 3000 at 3.0T. Triexponential fits were applied to calculate the molecular diffusion coefficient (D), the pseudo-diffusion coefficient (D*), the ultrahigh apparent diffusion coefficient (ADC uh ), and perfusion fraction (f). The interobserver and short-term interscan reproducibility were evaluated, and the change in these parameters with age were assessed. The D, ADC uh , and f values presented good to excellent reproducibility. With increasing age, a trend of increasing D values was observed, with significant difference in both peripheral zone (PZ, P = 0.01) and central gland (CG, P = 0.01) of normal prostate tissue. The f value increased in the CG beginning at 50 years of age while the ADC uh value decreased in the PZ after 50 years of age; all of them showed significant differences between groups A and C and groups B and C (P = 0.01/0.01). The D, ADC uh , and f values have good to excellent reproducibility in the normal prostate, and these values change with age. The ultrahigh b-values magnetic resonance imaging (MRI) can provide additional information (ADC uh ), which is different from the IVIM (intravoxel incoherent motion)-derived parameters. 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:801-812. © 2017 International Society for Magnetic Resonance in Medicine.
Braga, Lays Magalhães; Prado, Gustavo Faibischew; Umeda, Iracema Ioco Kikuchi; Kawauchi, Tatiana Satie; Taboada, Adriana Marques Fróes; Azevedo, Raymundo Soares; Pereira Filho, Horacio Gomes; Grupi, César José; Souza, Hayala Cristina Cavenague; Moreira, Dalmo Antônio Ribeiro; Nakagawa, Naomi Kondo
2016-01-01
Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86
Bauer, Jan Stefan; Noël, Peter Benjamin; Vollhardt, Christiane; Much, Daniela; Degirmenci, Saliha; Brunner, Stefanie; Rummeny, Ernst Josef; Hauner, Hans
2015-01-01
Purpose MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo. Material and Methods MR images of ten phantoms simulating subcutaneous fat of an infant’s torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE) sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days). This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence. Results In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility. Conclusion With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy. PMID:25706876
Bauer, Jan Stefan; Noël, Peter Benjamin; Vollhardt, Christiane; Much, Daniela; Degirmenci, Saliha; Brunner, Stefanie; Rummeny, Ernst Josef; Hauner, Hans
2015-01-01
MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo. MR images of ten phantoms simulating subcutaneous fat of an infant's torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE) sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days). This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence. In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility. With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.
Larsen, Nis Elbrønd; Haack, Søren; Larsen, Lars Peter Skovgaard; Pedersen, Erik Morre
2013-10-01
Diffusion weighted imaging (DWI) of the liver suffers from low signal to noise making 3 Tesla (3 T) an attractive option, but 3 T data is scarce. It was the aim to study the influence of different b values and respiratory compensation methods (RCM) on the apparent diffusion coefficient (ADC) level and on ADC reproducibility at 3 T. Ten healthy volunteers and 12 patients with malignant liver lesions underwent repeated (2-22 days) breathhold, free-breathing and respiratory triggered DWI at 3 T using b values between 0 and 1,000 s/mm(2). The ADCs changed up to 150% in healthy livers and up to 48% in malignant lesions depending on b value combinations. Best ADC reproducibility in healthy livers were obtained with respiratory triggering (95% limits of agreement: ±0.12) and free-breathing (±0.14). In malignant lesions equivalent reproducibility was obtained with less RCM dependence. The use of a lower maximum b value (b = 500) decreased reproducibility (±0.14 to ±0.32) in both normal liver and malignant lesions. Large differences in absolute ADC values and reproducibility caused by varying combinations of clinically realistic b values were demonstrated. Different RCMs caused smaller differences. Lowering maximum b value to 500 increased limits of agreement up to a factor of two. Serial ADC changes larger than approximately 15% can be detected confidently on an individual basis in both malignant lesions and normal liver parenchyma at 3 T using appropriate b values and respiratory compensation.
Periodontal repair in dogs: examiner reproducibility in the supraalveolar periodontal defect model.
Koo, Ki-Tae; Polimeni, Giuseppe; Albandar, Jasim M; Wikesjö, Ulf M E
2004-06-01
Histometric assessments are routinely used to evaluate biologic events ascertained in histologic sections acquired from animal and human studies. The objective of this study was to evaluate the intra- and inter-examiner reproducibility of histometric assessments in the supraalveolar periodontal defect model. Histometric analysis using incandescent and polarized light microscopy, an attached digital camera system, and a PC-based image analysis system including a custom program for the supraalveolar periodontal defect model was performed on histologic sections acquired from one jaw quadrant in each of 12 dogs. The animals had received an experimental protocol including implantation of a coral biomaterial and guided tissue regeneration (GTR) barrier devices, and were evaluated following a 4-week healing interval. Histometric parameters were recorded and repeated within a 3-month interval by two examiners following brief training. Intra- and inter-examiner reproducibility was assessed using the intra-class correlation coefficient (ICC). Most parameters showed high intra-examiner ICCs. Parameters including defect height, connective tissue repair, bone regeneration (height/area), formation of a junctional epithelium, positioning of the GTR device, ankylosis, root resorption, and defect area yielded an ICC> or 0..9. The ICCs for bone density and biomaterial density were somewhat lower (0.8 and 0.7, respectively). The inter-examiner reproducibility was somewhat lower compared to the intra-examiner reproducibility. Nevertheless, the ICCs were generally high (ICC range: 0.6-0.9). Histometric evaluations in the supraalveolar periodontal defect model yield highly reproducible results, in particular when a single examiner performs the histometric measurements, even when the examiner was exposed to limited training.
Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi
2016-07-30
We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55-75) with a BMI ≥27 and <40 kg/m², and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student's t-test comparisons. A total of 160 participants were included in the analysis. The Bland-Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of -0.65 and 0.22, respectively (R² = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability.
Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Gabriël, Sarah
2016-08-30
The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found. Copyright © 2016 Elsevier B.V. All rights reserved.
Khatib, Ahmed; Haji, Shaaban; Khamis, Maryam; Said, Christen; Khalid, Farhat; Dahoma, Mohammed; Ali, Ameir; Othman, Asha; Welty, Susie; McFarland, Willi
2017-07-01
To assess the reproducibility of respondent-driven sampling (RDS) in obtaining comparable samples across two survey rounds, we conducted integrated bio-behavioral surveillance surveys (IBBSS) using RDS in 2007 and 2011 among men who have sex with men (MSM) on Unguja island in Zanzibar. Differences in the two rounds were assessed by comparing RDS-adjusted population estimates, stratified estimates, and bottleneck plots. Participants in the 2011 survey round were younger (31.4 vs. 9.9% under 19 years old, p < 0.001), more likely to have tested for HIV in the last year (53.7 vs. 10.6%, p < 0.001), and less likely to have injected drugs in the last 3 months (1.0 vs. 23.2%, p < 0.001) compared to participants in the 2007 round. HIV prevalence was 12.3% in 2007 compared to 2.6% in 2011 (p < 0.001). The difference in HIV prevalence persisted after stratifying and adjusting for known differences in the two surveys rounds. Bottleneck plots suggest that recruitment chains were "trapped" in the social networks of MSM who injected drugs to a greater extent in 2007 than in 2011. We conclude that the two rounds of RDS sampled different subsets of the MSM population on Unguja, particularly with respect to inclusion of MSM within the social networks of people who inject drugs. Findings underscore the need to evaluate the reproducibility of RDS in repeated rounds of IBBSS and to develop new sampling methods for key populations at high risk for HIV in order to track the epidemic, develop evidence-based prevention and care programs, and assess their impact.
A new rapid method to measure human platelet cholesterol: a pilot study.
Jagroop, I Anita; Persaud, Jahm Want; Mikhailidis, Dimitri P
2011-01-01
Platelet cholesterol (PC) could be used to assess "tissue" cholesterol of patients with vascular disease. However, the methods available so far to measure PC involve a complex extraction process. We developed a rapid method to measure PC and assessed its correlation with serum total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), LDL-C/HDL-C ratio, triglycerides (TG), and non-HDL-C. We assessed repeatability (20 times, 3 participants) and reproducibility (8 times, 2 participants). A group of 47 healthy participants was studied. Blood was collected to analyze serum TC, LDL-C, HDL-C, and TG. Citrated blood was used to prepare a platelet pellet. A "clear soup" was produced (by disrupting this pellet using freeze-thaw and sonication cycles) and used to measure PC. Repeatability of PC showed a coefficient of variation (CV) of 4.8%. The reproducibility of PC over a period of 2 months was CV 7.5% and 8.1% (8 measurements for 2 participants). The PC of participants with serum LDL-C >2.6 mmol/L (treatment goal recommended by the National Cholesterol Education Program Adult Treatment Panel III) was 377 ± 120 μmol/10(12) platelets (n = 25). There was a significant correlation (Spearman, correlation coefficient) of PC (n = 25) with serum LDL-C (r(s) = 0.45, P = .02), LDL-C/HDL-C (r(s) = 0.45, P = .02), TG (r(s) = 0.43, P = .03), and non-HDL-C (r(s) = 0.53, P = .007). This technique of measuring PC has the advantage of being reproducible, fast, and simpler than previous methods. Thus, it may be useful for multiple sampling when investigating changes in PC in hypercholesterolemic patients. More extensive evaluation is necessary.