Spratt, D E; Jackson, W C; Abugharib, A; Tomlins, S A; Dess, R T; Soni, P D; Lee, J Y; Zhao, S G; Cole, A I; Zumsteg, Z S; Sandler, H; Hamstra, D; Hearn, J W; Palapattu, G; Mehra, R; Morgan, T M; Feng, F Y
2016-09-01
There has been a recent proposal to change the grading system of prostate cancer into a five-tier grade grouping system. The prognostic impact of this has been demonstrated in regards only to biochemical recurrence-free survival (bRFS) with short follow-up (3 years). Between 1990 and 2013, 847 consecutive men were treated with definitive external beam radiation therapy at a single academic center. To validate the new grade grouping system, bRFS, distant metastases-free survival (DMFS) and prostate cancer-specific survival (PCSS) were calculated. Adjusted Kaplan-Meier and multivariable Cox regression analyses were performed to assess the independent impact of the new grade grouping system. Discriminatory analyses were performed to compare the commonly used three-tier Gleason score system (6, 7 and 8-10) to the new system. The median follow-up of our cohort was 88 months. The 5-grade groups independently validated differing risks of bRFS (group 1 as reference; adjusted hazard ratio (aHR) 1.35, 2.16, 1.79 and 3.84 for groups 2-5, respectively). Furthermore, a clear stratification was demonstrated for DMFS (aHR 2.03, 3.18, 3.62 and 13.77 for groups 2-5, respectively) and PCSS (aHR 3.00, 5.32, 6.02 and 39.02 for groups 2-5, respectively). The 5-grade group system had improved prognostic discrimination for all end points compared with the commonly used three-tiered system (that is, Gleason score 6, 7 and 8-10). In a large independent radiotherapy cohort with long-term follow-up, we have validated the bRFS benefit of the proposed five-tier grade grouping system. Furthermore, we have demonstrated that the system is highly prognostic for DMFS and PCSS. Grade group 5 had markedly worse outcomes for all end points, and future work is necessary to improve outcomes in these patients.
Reclassification of serous ovarian carcinoma by a 2-tier system: a Gynecologic Oncology Group Study.
Bodurka, Diane C; Deavers, Michael T; Tian, Chunqiao; Sun, Charlotte C; Malpica, Anais; Coleman, Robert L; Lu, Karen H; Sood, Anil K; Birrer, Michael J; Ozols, Robert; Baergen, Rebecca; Emerson, Robert E; Steinhoff, Margaret; Behmaram, Behnaz; Rasty, Golnar; Gershenson, David M
2012-06-15
A study was undertaken to use the 2-tier system to reclassify the grade of serous ovarian tumors previously classified using the International Federation of Gynecology and Obstetrics (FIGO) 3-tier system and determine the progression-free survival (PFS) and overall survival (OS) of patients treated on Gynecologic Oncology Group (GOG) Protocol 158. The authors retrospectively reviewed demographic, pathologic, and survival data of 290 patients with stage III serous ovarian carcinoma treated with surgery and chemotherapy on GOG Protocol 158, a cooperative multicenter group trial. A blinded pathology review was performed by a panel of 6 gynecologic pathologists to verify histology and regrade tumors using the 2-tier system. The association of tumor grade with PFS and OS was assessed. Of 241 cases, both systems demonstrated substantial agreement when combining FIGO grades 2 and 3 (overall agreement, 95%; kappa statistic, 0.68). By using the 2-tier system, patients with low-grade versus high-grade tumors had significantly longer PFS (45.0 vs 19.8 months, respectively; P = .01). By using FIGO criteria, median PFS for patients with grade 1, 2, and 3 tumors was 37.5, 19.8, and 20.1 months, respectively (P = .07). There was no difference in clinical outcome in patients with grade 2 or 3 tumors in multivariate analysis. Woman with high-grade versus low-grade tumors demonstrated significantly higher risk of death (hazard ratio, 2.43; 95% confidence interval, 1.17-5.04; P = .02). Women with high-grade versus low-grade serous carcinoma of the ovary are 2 distinct patient populations. Adoption of the 2-tier grading system provides a simple yet precise framework for predicting clinical outcomes. Copyright © 2011 American Cancer Society.
Inferior turbinate classification system, grades 1 to 4: development and validation study.
Camacho, Macario; Zaghi, Soroush; Certal, Victor; Abdullatif, Jose; Means, Casey; Acevedo, Jason; Liu, Stanley; Brietzke, Scott E; Kushida, Clete A; Capasso, Robson
2015-02-01
To develop a validated inferior turbinate grading scale. Development and validation study. Phase 1 development (alpha test) consisted of a proposal of 10 different inferior turbinate grading scales (>1,000 clinic patients). Phase 2 validation (beta test) utilized 10 providers grading 27 standardized endoscopic photos of inferior turbinates using two different classification systems. Phase 3 validation (pilot study) consisted of 100 live consecutive clinic patients (n = 200 inferior turbinates) who were each prospectively graded by 18 different combinations of two independent raters, and grading was repeated by each of the same two raters, two separate times for each patient. In the development phase, 25% (grades 1-4) and 33% (grades 1-4) were the most useful systems. In the validation phase, the 25% classification system was found to be the best balance between potential clinical utility and ability to grade; the photo grading demonstrated a Cohen's kappa (κ) = 0.4671 ± 0.0082 (moderate inter-rater agreement). Live-patient grading with the 25% classification system demonstrated an overall inter-rater reliability of 71.5% (95% confidence interval [CI]: 64.8-77.3), with overall substantial agreement (κ = 0.704 ± 0.028). Intrarater reliability was 91.5% (95% CI: 88.7-94.3). Distribution for the 200 inferior turbinates was as follows: 25% quartile = grade 1, 50% quartile (median) = grade 2, 75% quartile = grade 3, and 90% quartile = grade 4. Mean turbinate size was 2.22 (95% CI: 2.07-2.34; standard deviation 1.02). Categorical κ was as follows: grade 1, 0.8541 ± 0.0289; grade 2, 0.7310 ± 0.0289; grade 3, 0.6997 ± 0.0289, and grade 4, 0.7760 ± 0.0289. The 25% (grades 1-4) inferior turbinate classification system is a validated grading scale with high intrarater and inter-rater reliability. This system can facilitate future research by tracking the effect of interventions on inferior turbinates. 2c. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Power-grade butanol recovery and utilization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noon, R.
1982-02-12
As an alternative to the traditional recovery systems, it was proposed in a previous publication that the n-butanol/acetone/ethanol fermentation products could be recovered as a power grade fuel blend and used directly as a fuel. This would affect a savings in process energy requirements because each chemical component would not have to be processed individually to technical grade purity. Further, some residual water could be tolerated in the fuel blend. To develop such a power grade fuel recovery scheme beyond the conceptual stage, the Energy Research and Resource Division of the Kansas Energy Office undertook a two-fold program to demonstratemore » and test a power grade butanol/acetone/ethanol fuel recovery system, and further to demonstrate the feasibility of using the fuel blend in a standard type engine. A development program was initiated to accomplish the following objectives: design and test an operational power grade butanol recovery plant that would operate at one liter per hour output; and test and assess the performance of power grade butanol in a spark ignition automotive engine. This project has demonstrated that recovery of a power grade butanol fuel blend is simple and can be accomplished at a considered energy advantage over ethanol. It was further demonstrated that such a power grade blend works well in a typical spark ignition engine.« less
Grading for Understanding--Standards-Based Grading
ERIC Educational Resources Information Center
Zimmerman, Todd
2017-01-01
Standards-based grading (SBG), sometimes called learning objectives-based assessment (LOBA), is an assessment model that relies on students demonstrating mastery of learning objectives (sometimes referred to as standards). The goal of this grading system is to focus students on mastering learning objectives rather than on accumulating points. I…
ERIC Educational Resources Information Center
Maryland State Dept. of Education, Baltimore.
The Maryland School Performance Program for 1992 puts forward social studies outcomes and indicators for grades K-3, grades 4-5, and grades 6-8. Specific indicators for each grade grouping further delineate the following seven individual outcomes: (1) political systems--students will demonstrate an understanding of the historical development and…
Grading Matters in Theological Education
ERIC Educational Resources Information Center
Blodgett, Barbara J.
2017-01-01
Grading systems matter more to the teaching and learning enterprise than many teachers may realize, as demonstrated in the author's experience of adopting a new one. Different systems emphasize different values such as excellence vs. perfection, achievement vs. talent, and second chances vs. partial credit. The author relates her experiment with…
Computer-Aided Grading of Lymphangioleiomyomatosis (LAM) using HRCT
Yao, Jianhua; Avila, Nilo; Dwyer, Andrew; Taveira-DaSilva, Angelo M.; Hathaway, Olanda M.; Moss, Joel
2010-01-01
Lymphangioleiomyomatosis (LAM) is a multisystem disorder associated with proliferation of smooth muscle-like cells, which leads to destruction of lung parenchyma. Subjective grading of LAM on HRCT is imprecise and can be arduous especially in cases with severe involvement. We propose a computer-aided evaluation system that grades LAM involvement based on analysis of lung texture patterns. A committee of support vector machines is employed for classification. The system was tested on 36 patients. The computer grade demonstrates good correlation with subjective radiologist grade (R=0.91, p<0.0001) and pulmonary functional tests (R=0.85, p<0.0001). The grade also provides precise progression assessment of disease over time. PMID:21625320
ERIC Educational Resources Information Center
Skokie School District 68, IL.
A Chicago suburban public school with approximately 450 children per grade level demonstrated a system-wide program for identification, diagnosis, and educational treatment of children with learning disabilities in grades 2 through 6. Children were judged to underachieve when achievement measures in language or mathematics fell more than 10% below…
Direct-write graded index materials realized in protein hydrogels
Kaehr, Bryan; Scrymgeour, David A.
2016-09-20
Here, the ability to create optical materials with arbitrary index distributions would prove transformative for optics design and applications. However, current fabrication techniques for graded index (GRIN) materials rely on diffusion profiles and therefore are unable to realize arbitrary distribution GRIN design. Here, we demonstrate the laser direct writing of graded index structures in protein-based hydrogels using multiphoton lithography. We show index changes spanning a range of 10 –2, which is comparable with laser densified glass and polymer systems. Further, we demonstrate the conversion of these written density variation structures into SiO 2, opening up the possibility of transforming GRINmore » hydrogels to a wide range of material systems.« less
Direct-write graded index materials realized in protein hydrogels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaehr, Bryan; Scrymgeour, David A.
Here, the ability to create optical materials with arbitrary index distributions would prove transformative for optics design and applications. However, current fabrication techniques for graded index (GRIN) materials rely on diffusion profiles and therefore are unable to realize arbitrary distribution GRIN design. Here, we demonstrate the laser direct writing of graded index structures in protein-based hydrogels using multiphoton lithography. We show index changes spanning a range of 10 –2, which is comparable with laser densified glass and polymer systems. Further, we demonstrate the conversion of these written density variation structures into SiO 2, opening up the possibility of transforming GRINmore » hydrogels to a wide range of material systems.« less
Liu, Dennis B; Palmer, Blake; Herndon, C D Anthony; Maizels, Max
2015-08-01
It is unclear how clinicians learn to grade pediatric hydronephrosis (HN) and how effective their training has been. We sought to: 1. Assess how clinicians learn to grade HN and their confidence in their training and abilities and 2. To assess Computer Enhanced Visual Learning (CEVL) e-Learning to learn the Society for Fetal Urology (SFU) grading system for pediatric HN. A multi-institutional online survey was distributed to pediatric urologists, nephrologists, and radiologists. Respondents used a 6-point Likert scale (0 = not confident to 5 = very confident) to assess their confidence in knowledge of the criteria, indications, and ability to grade HN, and how they learned to grade. Participants assigned SFU grades to 15 neonatal ultrasounds (US). A CEVL module on the SFU grading system was accessed and a post-CEVL survey completed. Changes in confidence and accuracy of grading were compared before and after CEVL e-Learning. The most common method of learning was "casually during training" (44.5%). Significant increases in confidence in knowledge of criteria, indications, and ability to grade, as well as the accuracy of grading were seen following CEVL e-Learning (Figure A and B). Although the SFU grading system is considered the predominant grading system for HN, its application in clinical practice has been inconsistent. While this may be due to the grading system itself, it is possible that deficient training and confidence are the root causes. Our data supports this by demonstrating that most clinicians receive only casual training and accordingly, report low confidence in their knowledge and ability to grade HN. Therefore, we conclude that there exists a strong need to improve the teaching of the SFU grading system. e-Learning has been shown to be effective in teaching difficult topics and skills. We demonstrate that e-Learning with CEVL is effective in increasing both the confidence and accuracy of SFU grading of pediatric HN. Limitations of our study include a small sample size, low response rate, and discrepant participation. Furthermore, we did not assess the extent to which the CEVL module was used or include a control group learning through traditional means. Therefore, we were unable to evaluate the efficiency of learning or be certain that the improvements seen were derived exclusively from CEVL. Current training in SFU grading of HN is mostly unstructured and inaccurate grading is common. Learners who use CEVL show improvements in their confidence and ability to SFU grade HN. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Baker, Marshall S; Sherman, Karen L; Stocker, Susan; Hayman, Amanda V; Bentrem, David J; Prinz, Richard A; Talamonti, Mark S
2013-02-01
Established systems for grading postoperative complications do not change the assigned grade when multiple interventions or readmissions are required to manage a complication. Studies using these systems may misrepresent outcomes for the surgical procedures being evaluated. We define a quality outcome for distal pancreatectomy (DP) and use this metric to compare laparoscopic distal pancreatectomy (LDP) to open distal pancreatectomy (ODP). Records for patients undergoing DP between January 2006 and December 2009 were reviewed. Clavien-Dindo grade IIIb, IV, and V complications were classified as severe adverse--poor quality--postoperative outcomes (SAPOs). II and IIIa complications requiring either significantly prolonged overall lengths of stay including readmissions within 90 days or more than one invasive intervention were also classified as SAPOs. By Clavien-Dindo system alone, 91 % of DP patients had either no complication or a low/moderate grade (I, II, IIIa) complication. Using our reclassification, however, 25 % had a SAPO. Patients undergoing LDP demonstrated a Clavien-Dindo complication profile identical to that for SDP but demonstrated significantly shorter overall lengths of stay, were less likely to require perioperative transfusion, and less likely to have a SAPO. Established systems undergrade the severity of some complications following DP. Using a procedure-specific metric for quality, we demonstrate that LDP affords a higher quality postoperative outcome than ODP.
Tanaka, Kazuhiro; Hasegawa, Tadashi; Nojima, Takayuki; Oda, Yoshinao; Mizusawa, Junki; Fukuda, Haruhiko; Iwamoto, Yukihide
2016-04-18
The correct clinical staging of soft tissue sarcomas (STS) is critical for the selection of treatments. The staging system consists of histological grade of the tumors and French Federation of Cancer Center (FNCLCC) system based on mitotic count is widely used for the grading. In this study, we compared the validity and usefulness of Ki-67 grading system with FNCLCC system in JCOG0304 trial which investigated the efficacy and safety of perioperative chemotherapy with doxorubicin and ifosfamide for STS. All 70 eligible patients with STS in the extremities treated by perioperative chemotherapy in JCOG0304 were analyzed. Univariate and multivariate Cox regression analyses were conducted to investigate an influence on overall survival. The reproducibility of Ki-67 grading system in the histological grading of STS was higher than FNCLCC system (κ = 0.54 [95 % CI 0.39-0.71], and 0.46 [0.32-0.62], respectively). Although FNCLCC grade was not associated with overall survival (OS) in univariate analysis (HR 2.80 [0.74-10.55], p = 0.13), Ki-67 grading system had a tendency to associate with OS in univariate analysis (HR 4.12 [0.89-19.09], p = 0.07) and multivariate analysis with backward elimination (HR 3.51 [0.75-16.36], p = 0.11). This is the first report demonstrating the efficacy of Ki-67 grading system for the patients with STS in the prospective trial. The results indicate that Ki-67 grading system might be useful for the evaluation of histological grade of STS.
Hernandez, Matthew C; Kong, Victor Y; Aho, Johnathon M; Bruce, John L; Polites, Stephanie F; Laing, Grant L; Zielinski, Martin D; Clarke, Damian L
2017-07-01
Severity of emergency general surgery (EGS) diseases has not been standardized until recently. The American Association for the Surgery of Trauma (AAST) proposed an anatomic severity grading system for EGS diseases to facilitate communication and quality comparisons between providers and hospitals. Previous work has demonstrated validity of the system for appendicitis in the United States. To demonstrate generalizability, we aim to externally validate this grading system in South African patients with appendicitis. Patients with acute appendicitis during 2010 to 2016 were identified at multi-institutional sites within South Africa. Baseline demographics and procedure types were recorded, and AAST grades were assigned based on intraoperative findings. Outcomes included duration of stay, mortality, and Clavien-Dindo complications. Summary statistical univariate and nominal logistic regression analyses were performed to compare AAST grade and outcomes. A total of 1,415 patients with a median (interquartile range) age of 19 years (14-28 years) were included (55% men). One hundred percent underwent appendectomy: 63.5% completed via midline laparotomy, 36.5% via limited incision (31.8% via McBurney incision and 4.7% via laparoscopy). Overall, 30-day mortality rate was 1.4% with an overall complication rate of 44%. Most common complications included surgical site infection (n = 147, 10.4%), pneumonia (n = 105, 7.4%), and renal failure (n = 64, 4.5%). Distribution of AAST grade is as follows: Grade 0 (10, 0.7%), Grade 1 (247, 17.4%), Grade 2 (280, 19.8%), Grade 3 (158, 11.3%), Grade 4 (179, 12.6%), and Grade 5 (541, 38.2%). Increased median (interquartile range) AAST grades were recorded in patients with complications, 5 (3-5) compared with those without (2 [1-3], p = 0.001). Duration of stay was increased for patients with higher AAST grades: 4 and 5 (10.6 ± 5.9 days) versus I and II (3.6 ± 4.3 days; p = 0.001). Area under the receiver operating characteristic analysis to predict presence of any complication based on AAST grade was 0.90. The AAST EGS grading system is valid to predict important clinical outcomes in a South African population with an increased degree of severity on presentation. These results support generalizability of the AAST EGS grading system for appendicitis in a developing nation. Prognostic, level II.
Brosseau, Lucie; Taki, Jade; Desjardins, Brigit; Thevenot, Odette; Fransen, Marlene; Wells, George A; Imoto, Aline Mizusaki; Toupin-April, Karine; Westby, Marie; Gallardo, Inmaculada C Álvarez; Gifford, Wendy; Laferrière, Lucie; Rahman, Prinon; Loew, Laurianne; Angelis, Gino De; Cavallo, Sabrina; Shallwani, Shirin Mehdi; Aburub, Ala'; Bennell, Kim L; Van der Esch, Martin; Simic, Milena; McConnell, Sara; Harmer, Alison; Kenny, Glen P; Paterson, Gail; Regnaux, Jean-Philippe; Lefevre-Colau, Marie-Martine; McLean, Linda
2017-05-01
To identify effective mind-body exercise programs and provide clinicians and patients with updated, high-quality recommendations concerning non-traditional land-based exercises for knee osteoarthritis. A systematic search and adapted selection criteria included comparative controlled trials with mind-body exercise programs for patients with knee osteoarthritis. A panel of experts reached consensus on the recommendations using a Delphi survey. A hierarchical alphabetical grading system (A, B, C+, C, D, D+, D-) was used, based on statistical significance ( P < 0.5) and clinical importance (⩾15% improvement). The four high-quality studies identified demonstrated that various mind-body exercise programs are promising for improving the management of knee osteoarthritis. Hatha Yoga demonstrated significant improvement for pain relief (Grade B) and physical function (Grade C+). Tai Chi Qigong demonstrated significant improvement for quality of life (Grade B), pain relief (Grade C+) and physical function (Grade C+). Sun style Tai Chi gave significant improvement for pain relief (Grade B) and physical function (Grade B). Mind-body exercises are promising approaches to reduce pain, as well as to improve physical function and quality of life for individuals with knee osteoarthritis.
Course Syllabus for Grades 9-12, Music. Chorus (I-IV).
ERIC Educational Resources Information Center
Murray State Univ., KY.
Teachers in the Henry County Public School System (Tennessee) developed and wrote over 80 course syllabi for most subject areas taught in grades seven through twelve as part of a Teacher Corps demonstration project. This syllabus is intended to inform students and parents of the requirements at each grade level of a four-year chorus program. The…
Wollersheim Shervey, Sarah; Sandilos, Lia E; DiPerna, James C; Lei, Pui-Wa
2017-09-01
The purpose of this study was to examine the social validity of the Social Skills Improvement System-Classwide Intervention Program (SSIS-CIP) for teachers in the primary grades. Participants included 45 first and second grade teachers who completed a 16-item social validity questionnaire during each year of the SSIS-CIP efficacy trial. Findings indicated that teachers generally perceived the SSIS-CIP as a socially valid and feasible intervention for primary grades; however, teachers' ratings regarding ease of implementation and relevance and sequence demonstrated differences across grade levels in the second year of implementation. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Accordion complication grading predicts short-term outcome after right colectomy.
Klos, Coen L; Safar, Bashar; Hunt, Steven R; Wise, Paul E; Birnbaum, Elisa H; Mutch, Matthew G; Fleshman, James W; Dharmarajan, Sekhar
2014-08-01
The Accordion severity grading system is a novel system to score the severity of postoperative complications in a standardized fashion. This study aims to demonstrate the validity of the Accordion system in colorectal surgery by correlating severity grades with short-term outcomes after right colectomy for colon cancer. This is a retrospective cohort review of patients who underwent right colectomy for cancer between January 1, 2002, and January 31, 2007, at a single tertiary care referral center. Complications were categorized according to the Accordion severity grading system: grades 1 (mild), 2 (moderate), 3-5 (severe), and 6 (death). Outcome measures were hospital stay, 30-d readmission rate and 1-y survival. Correlation between Accordion grades and outcome measures is reflected by Spearman rho (ρ). One-year survival was obtained per Kaplan-Meier method and compared by logrank test for trend. Significance was set at P ≤ 0.05. Overall, 235 patients underwent right colectomy for cancer of which 122 (51.9%) had complications. In total, 52 (43%) had an Accordion grade 1 complication; 44 (36%) grade 2; four (3%) grade 3; 11 (9%) grade 4; seven (6%) grade 5; and four (3%) grade 6. There was significant correlation between Accordion grades and hospital stay (ρ = 0.495, P < 0.001) and 30-d readmission rate (ρ = 0.335, P < 0.001). There was a significant downward trend in 1-y survival as complication severity by Accordion grade increased (P = 0.02). The Accordion grading system is a useful tool to estimate short-term outcomes after right colectomy for cancer. High-grade Accordion complications are associated with longer hospital stay and increased risk of readmission and mortality. Published by Elsevier Inc.
An endoscopic mucosal grading system is predictive of leak in stapled rectal anastomoses.
Sujatha-Bhaskar, Sarath; Jafari, Mehraneh D; Hanna, Mark; Koh, Christina Y; Inaba, Colette S; Mills, Steven D; Carmichael, Joseph C; Nguyen, Ninh T; Stamos, Michael J; Pigazzi, Alessio
2018-04-01
Anastomotic leak is a devastating postoperative complication following rectal anastomoses associated with significant clinical and oncological implications. As a result, there is a need for novel intraoperative methods that will help predict anastomotic leak. From 2011 to 2014, patient undergoing rectal anastomoses by colorectal surgeons at our institution underwent prospective application of intraoperative flexible endoscopy with mucosal grading. Retrospective review of patient medical records was performed. After creation of the colorectal anastomosis, application of a three-tier endoscopic mucosal grading system occurred. Grade 1 was defined as circumferentially normal appearing peri-anastomotic mucosa. Grade 2 was defined as ischemia or congestion involving <30% of either the colon or rectal mucosa. Grade 3 was defined as ischemia or congestion involving >30% of the colon or rectal mucosa or ischemia/congestion involving both sides of the staple line. From 2011 to 2014, a total of 106 patients were reviewed. Grade 1 anastomoses were created in 92 (86.7%) patients and Grade 2 anastomoses were created in 10 (9.4%) patients. All 4 (3.8%) Grade 3 patients underwent immediate intraoperative anastomosis takedown and re-creation, with subsequent re-classification as Grade 1. Demographic and comorbidity data were similar between Grade 1 and Grade 2 patients. Anastomotic leak rate for the entire cohort was 12.2%. Grade 1 patients demonstrated a leak rate of 9.4% (9/96) and Grade 2 patients demonstrated a leak rate of 40% (4/10). Multivariate logistic regression associated Grade 2 classification with an increased risk of anastomotic leak (OR 4.09, 95% CI 1.21-13.63, P = 0.023). Endoscopic mucosal grading is a feasible intraoperative technique that has a role following creation of a rectal anastomosis. Identification of a Grade 2 or Grade 3 anastomosis should provoke strong consideration for immediate intraoperative revision.
Geber, Christian; Baumgärtner, Ulf; Schwab, Rainer; Müller, Harald; Stoeter, Peter; Dieterich, Marianne; Sommer, Clemens; Birklein, Frank; Treede, Rolf-Detlef
2009-10-01
The definition of neuropathic pain has recently been revised by an expert committee of the Neuropathic Pain Special Interest Group of the International Association for the Study of Pain (NeuPSIG) as "pain arising as direct consequence of a lesion or disease affecting the somatosensory system," and a grading system of "definite," "probable," and "possible" neuropathic pain has been introduced. This open case series of 5 outpatients (3 men, 2 women; mean age 48 +/- 12 years) demonstrates how the grading system can be applied, in combination with appropriate confirmatory testing, to diagnosis neuropathic conditions in clinical practice. The proposed grading system includes a dynamic algorithm that enhances the physician's ability to determine with a greater level of certainty whether a pain condition is neuropathic. Its clinical use should be further validated in prospective studies.
Rickard, Mandy; Easterbrook, Bethany; Kim, Soojin; Farrokhyar, Forough; Stein, Nina; Arora, Steven; Belostotsky, Vladamir; DeMaria, Jorge; Lorenzo, Armando J; Braga, Luis H
2017-02-01
The urinary tract dilation (UTD) classification system was introduced to standardize terminology in the reporting of hydronephrosis (HN), and bridge a gap between pre- and postnatal classification such as the Society for Fetal Urology (SFU) grading system. Herein we compare the intra/inter-rater reliability of both grading systems. SFU (I-IV) and UTD (I-III) grades were independently assigned by 13 raters (9 pediatric urology staff, 2 nephrologists, 2 radiologists), twice, 3 weeks apart, to 50 sagittal postnatal ultrasonographic views of hydronephrotic kidneys. Data regarding ureteral measurements and bladder abnormalities were included to allow proper UTD categorization. Ten images were repeated to assess intra-rater reliability. Krippendorff's alpha coefficient was used to measure overall and by grade intra/inter-rater reliability. Reliability between specialties and training levels were also analyzed. Overall inter-rater reliability was slightly higher for SFU (α = 0.842, 95% CI 0.812-0.879, in session 1; and α = 0.808, 95% CI 0.775-0.839, in session 2) than for UTD (α = 0.774, 95% CI 0.715-0.827, in session 1; and α = 0.679, 95% CI 0.605-0.750, in session 2). Reliability for intermediate grades (SFU II/III and UTD 2) of HN was poor regardless of the system. Reliabilities for SFU and UTD classifications among Urology, Nephrology, and Radiology, as well as between training levels were not significantly different. Despite the introduction of HN grading systems to standardize the interpretation and reporting of renal ultrasound in infants with HN, none have been proven superior in allowing clinicians to distinguish between "moderate" grades. While this study demonstrated high reliability in distinguishing between "mild" (SFU I/II and UTD 1) and "severe" (SFU IV and UTD 3) grades of HN, the overall reliability between specialties was poor. This is in keeping with a previous report of modest inter-rater reliability of the SFU system. This drawback is likely explained by the subjective interpretation required to assign grades, which can be impacted by experience, image quality, and scanning technique. As shown in the figure, which demonstrates SFU II (a) and SFU III (b), as assigned by a radiologist, it is possible to make an argument that either of these images can be classified into both categories that were observed during the grading sessions of this study. Although both systems have acceptable reliability, the SFU grading system showed higher overall intra/inter-rater reliability regardless of rater specialty than the UTD classification. Inter-rater reliability for SFU grades II/III and UTD 2 was low, highlighting the limitations of both classifications in regards to properly segregating moderate HN grades. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Development of a plasma sprayed ceramic gas path seal for high pressure turbine applications
NASA Technical Reports Server (NTRS)
Shiembob, L. T.
1977-01-01
The plasma sprayed graded layered yittria stabilized zirconia (ZrO2)/metal(CoCrAlY) seal system for gas turbine blade tip applications up to 1589 K (2400 F) seal temperatures was studied. Abradability, erosion, and thermal fatigue characteristics of the graded layered system were evaluated by rig tests. Satisfactory abradability and erosion resistance was demonstrated. Encouraging thermal fatigue tolerance was shown. Initial properties for the plasma sprayed materials in the graded, layered seal system was obtained, and thermal stress analyses were performed. Sprayed residual stresses were determined. Thermal stability of the sprayed layer materials was evaluated at estimated maximum operating temperatures in each layer. Anisotropic behavior in the layer thickness direction was demonstrated by all layers. Residual stresses and thermal stability effects were not included in the analyses. Analytical results correlated reasonably well with results of the thermal fatigue tests. Analytical application of the seal system to a typical gas turbine engine application predicted performance similar to rig specimen thermal fatigue performance. A model for predicting crack propagation in the sprayed ZrO2/CoCrAlY seal system was proposed, and recommendations for improving thermal fatigue resistance were made. Seal system layer thicknesses were analytically optimized to minimize thermal stresses in the abradability specimen during thermal fatigue testing. Rig tests on the optimized seal configuration demonstrated some improvement in thermal fatigue characteristics.
The Atlanta Public School's Dropout Initiative: A Demonstration Project.
ERIC Educational Resources Information Center
Jonas, Edward D., Jr.; Amuleru-Marshall, Nancy
This project proposes the development and implementation of a model system for collecting, documenting, and reporting to the Atlanta (Georgia) Board of Education information that will indicate the number, ages, and grades of students dropping out of the Atlanta Public School System (APS). Furthermore, this project will demonstrate an effective…
Brosseau, Lucie; Taki, Jade; Desjardins, Brigit; Thevenot, Odette; Fransen, Marlene; Wells, George A; Mizusaki Imoto, Aline; Toupin-April, Karine; Westby, Marie; Álvarez Gallardo, Inmaculada C; Gifford, Wendy; Laferrière, Lucie; Rahman, Prinon; Loew, Laurianne; De Angelis, Gino; Cavallo, Sabrina; Shallwani, Shirin Mehdi; Aburub, Ala'; Bennell, Kim L; Van der Esch, Martin; Simic, Milena; McConnell, Sara; Harmer, Alison; Kenny, Glen P; Paterson, Gail; Regnaux, Jean-Philippe; Lefevre-Colau, Marie-Martine; McLean, Linda
2017-05-01
To identify effective strengthening exercise programs and provide rehabilitation teams and patients with updated, high-quality recommendations concerning traditional land-based exercises for knee osteoarthritis. A systematic search and adapted selection criteria included comparative controlled trials with strengthening exercise programs for patients with knee osteoarthritis. A panel of experts reached consensus on the recommendations using a Delphi survey. A hierarchical alphabetical grading system (A, B, C+, C, D, D+ or D-) was based on statistical significance ( p < 0.5) and clinical importance (⩾15% improvement). The 26 high-quality studies identified demonstrated that various strengthening exercise programs with/without other types of therapeutic exercises are generally effective for improving knee osteoarthritis management within a six-month period. Strengthening exercise programs demonstrated a significant improvement for pain relief (four Grade A, ten Grade B, two Grade C+), physical function (four Grade A, eight Grade B) and quality of life (three Grade B). Strengthening in combination with other types of exercises (coordination, balance, functional) showed a significant improvement in pain relief (three Grade A, 11 Grade B, eight Grade C+), physical function (two Grade A, four Grade B, three Grade C+) and quality of life (one Grade A, one Grade C+). There are a variety of choices for strengthening exercise programs with positive recommendations for healthcare professionals and knee osteoarthritis patients. There is a need to develop combined behavioral and muscle-strengthening strategies to improve long-term maintenance of regular strengthening exercise programs.
NASA Technical Reports Server (NTRS)
1981-01-01
The engineering design, fabrication, assembly, operation, economic analysis, and process support research and development for an Experimental Process System Development Unit for producing semiconductor-grade silicon using the slane-to-silicon process are reported. The design activity was completed. About 95% of purchased equipment was received. The draft of the operations manual was about 50% complete and the design of the free-space system continued. The system using silicon power transfer, melting, and shotting on a psuedocontinuous basis was demonstrated.
Collection of low-grade waste heat for enhanced energy harvesting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dede, Ercan M., E-mail: eric.dede@tema.toyota.com; Schmalenberg, Paul; Wang, Chi-Ming
Enhanced energy harvesting through the collection of low-grade waste heat is experimentally demonstrated. A structural optimization technique is exploited in the design of a thermal-composite substrate to guide and gather the heat emanating from multiple sources to a predetermined location. A thermoelectric generator is then applied at the selected focusing region to convert the resulting low-grade waste heat to electrical power. The thermal characteristics of the device are experimentally verified by direct temperature measurements of the system and numerically validated via heat conduction simulations. Electrical performance under natural and forced convection is measured, and in both cases, the device withmore » optimized heat flow control plus energy harvesting demonstrates increased power generation when compared with a baseline waste heat recovery system. Electronics applications include energy scavenging for autonomously powered sensor networks or self-actuated devices.« less
Outcome prediction of third ventriculostomy: a proposed hydrocephalus grading system.
Kehler, U; Regelsberger, J; Gliemroth, J; Westphal, M
2006-08-01
An important factor in making a recommendation for different treatment modalities in hydrocephalus patients (VP shunt versus endoscopic third ventriculostomy) is the definition of the underlying pathology which determines the prognosis/outcome of the surgical procedure. Third ventriculostomies (3rd VS) are successful mainly in obstructive hydrocephalus but also in some subtypes of communicating hydrocephalus. A simple, easily applicable grading system that is designed to predict the outcome of 3rd VS is proposed. The hydrocephalus is graded on the basis of the extent of downward bulging of the floor of the third ventricle, which reflects the pressure gradient between the 3rd ventricle and the basal cisterns, presence of directly visualised CSF pathway obstruction in MRI, and the progression of the clinical symptoms resulting in five different grades. In this proposed grading system, grade 1 hydrocephalus subtype shows no downward bulged floor of the 3rd ventricle, no obstruction of the CSF pathway, and no progressive symptoms of hydrocephalus. There is no indication for 3rd VS. Grades 2 to 4 show different combinations of the described parameters. Grade 5 subtype shows a markedly downward bulged floor of the 3rd ventricle and direct detection of the CSF pathway obstruction (i.e., aqueductal stenosis) with progressive clinical deterioration. Retrospective application of this grading scheme to a series of 72 3rd VS has demonstrated a high correlation with the outcome: The success rate in grade 3 reached 40%, in grade 4: 58%, and in grade 5: 95%. This standardised grading system predicts the outcome of 3rd VS and helps in decision making for 3rd VS versus VP shunting.
Kepler, Christopher K; Vaccaro, Alexander R; Koerner, John D; Dvorak, Marcel F; Kandziora, Frank; Rajasekaran, Shanmuganathan; Aarabi, Bizhan; Vialle, Luiz R; Fehlings, Michael G; Schroeder, Gregory D; Reinhold, Maximilian; Schnake, Klaus John; Bellabarba, Carlo; Cumhur Öner, F
2016-04-01
The aims of this study were (1) to demonstrate the AOSpine thoracolumbar spine injury classification system can be reliably applied by an international group of surgeons and (2) to delineate those injury types which are difficult for spine surgeons to classify reliably. A previously described classification system of thoracolumbar injuries which consists of a morphologic classification of the fracture, a grading system for the neurologic status and relevant patient-specific modifiers was applied to 25 cases by 100 spinal surgeons from across the world twice independently, in grading sessions 1 month apart. The results were analyzed for classification reliability using the Kappa coefficient (κ). The overall Kappa coefficient for all cases was 0.56, which represents moderate reliability. Kappa values describing interobserver agreement were 0.80 for type A injuries, 0.68 for type B injuries and 0.72 for type C injuries, all representing substantial reliability. The lowest level of agreement for specific subtypes was for fracture subtype A4 (Kappa = 0.19). Intraobserver analysis demonstrated overall average Kappa statistic for subtype grading of 0.68 also representing substantial reproducibility. In a worldwide sample of spinal surgeons without previous exposure to the recently described AOSpine Thoracolumbar Spine Injury Classification System, we demonstrated moderate interobserver and substantial intraobserver reliability. These results suggest that most spine surgeons can reliably apply this system to spine trauma patients as or more reliably than previously described systems.
Gonnella, Joseph S; Erdmann, James B; Hojat, Mohammadreza
2004-04-01
Context It is important to establish the predictive validity of medical school grades. The strength of predictive validity and the ability to identify at-risk students in medical schools depends upon assessment systems such as number grades, pass/fail (P/F) or honours/pass/fail (H/P/F) systems. Objective This study was designed to examine the predictive validity of number grades in medical school, and to determine whether any important information is lost in a shift from number to P/F and H/P/F grading systems. Subjects The participants in this prospective, longitudinal study were 6656 medical students who studied at Jefferson Medical College over 3 decades. They were grouped into 10 deciles based on their number grades in Year 1 of medical school. Methods Participants were compared on academic accomplishments in Years 2 and 3 of medical school, medical school class rank, delayed graduation and attrition, performance on medical licensing examinations and clinical competence ratings in the first postgraduate year. Results Results supported the short- and longterm predictive validity of the number grades. Ratings of clinical competence beyond medical school were predicted by number grades in medical school. We demonstrated that small differences in number grades are statistically meaningful, and that important information for identifying students in need of remedial education is lost when students who narrowly meet faculty's expectations are included with the rest of the class in a broad 'pass' category. Conclusions The findings refute the argument that knowledge of sciences basic to medicine is not critical to subsequent performance in medical school and beyond if an appropriate evaluation system is used. Furthermore, the results of this study raise questions about abandoning number grades in favour of a pass/fail system. Consideration of these findings in policy decisions regarding assessment systems of medical students is recommended.
An Autograding (Student) Problem Management System for the Compeuwtir Ilittur8
NASA Technical Reports Server (NTRS)
Kohne, Glenn S.
1996-01-01
In order to develop analysis skills necessary in engineering disciplines, students need practice solving problems using specified analytical techniques. Unless homework is collected and graded, students tend not to spend much time or effort in performing it. Teachers do not, realistically, have the time to grade large numbers of homework problems on a regular basis. This paper presents and makes available a miracle cure. The Autograding Problem Management System (APMS) provides a discipline-independent mechanism for teachers to create (quickly and easily) sets of homework problems. The APMS system provides CRT and/or printed summaries of the graded student responses. This presentation will demonstrate both the speed and the drag-and-drop simplicity of using the APMS to create self-grading homework problem sets comprised of traditional types of problems and of problems which would not be possible without the use of computers.
Brosseau, Lucie; Taki, Jade; Desjardins, Brigit; Thevenot, Odette; Fransen, Marlene; Wells, George A; Mizusaki Imoto, Aline; Toupin-April, Karine; Westby, Marie; Álvarez Gallardo, Inmaculada C; Gifford, Wendy; Laferrière, Lucie; Rahman, Prinon; Loew, Laurianne; De Angelis, Gino; Cavallo, Sabrina; Shallwani, Shirin Mehdi; Aburub, Ala'; Bennell, Kim L; Van der Esch, Martin; Simic, Milena; McConnell, Sara; Harmer, Alison; Kenny, Glen P; Paterson, Gail; Regnaux, Jean-Philippe; Lefevre-Colau, Marie-Martine; McLean, Linda
2017-05-01
To identify effective aerobic exercise programs and provide clinicians and patients with updated, high-quality recommendations concerning traditional land-based exercises for knee osteoarthritis. A systematic search and adapted selection criteria included comparative controlled trials with strengthening exercise programs for patients with knee osteoarthritis. A panel of experts reached consensus on the recommendations using a Delphi survey. A hierarchical alphabetical grading system (A, B, C+, C, D, D+, or D-) was used, based on statistical significance ( P < 0.5) and clinical importance (⩾15% improvement). The five high-quality studies included demonstrated that various aerobic training exercises are generally effective for improving knee osteoarthritis within a 12-week period. An aerobic exercise program demonstrated significant improvement for pain relief (Grade B), physical function (Grade B) and quality of life (Grade C+). Aerobic exercise in combination with strengthening exercises showed significant improvement for pain relief (3 Grade A) and physical function (2 Grade A, 2 Grade B). A short-term aerobic exercise program with/without muscle strengthening exercises is promising for reducing pain, improving physical function and quality of life for individuals with knee osteoarthritis.
ERIC Educational Resources Information Center
Haggart, S. A.; Furry, W. S.
This Working Note documents the first year's events and outcomes in developing the budgeting system and resource allocation rules to support the Education Voucher Demonstration. The district now has systems for per pupil resource allocation and school/minischool cost center accounting. The basic voucher of $1,041 for grades 7-8, and $788 for…
Dagher, Julien; Delahunt, Brett; Rioux-Leclercq, Nathalie; Egevad, Lars; Srigley, John R; Coughlin, Geoffrey; Dunglinson, Nigel; Gianduzzo, Troy; Kua, Boon; Malone, Greg; Martin, Ben; Preston, John; Pokorny, Morgan; Wood, Simon; Yaxley, John; Samaratunga, Hemamali
2017-12-01
In 2012, the International Society of Urological Pathology (ISUP) introduced a novel grading system for clear cell renal cell carcinoma (ccRCC) and papillary renal cell carcinoma. This system is incorporated into the latest World Health Organization renal tumour classification, being designated WHO/ISUP grading. This study was undertaken to compare WHO/ISUP and Fuhrman grading and to validate WHO/ISUP grading as a prognostic parameter in a series of clear cell RCC. Analysis of 681 cases of ccRCC showed that 144 tumours could not be assigned a Fuhrman grade on the basis of ambiguous grading features. The application of WHO/ISUP grading resulted in a general down-grading of cases when compared with Fuhrman grading. In a sub-group of 374 cases, for which outcome data were available, 9.3% were WHO/ISUP grade 1, 50.3% were grade 2, 24.1% grade 3 and 16.3% grade 4, while the distribution of Fuhrman grades was 0.4% grade 1, 48.7% grade 2, 29.4% grade 3 and 21.5% grade 4. There were no recurrence/metastases amongst patients with WHO/ISUP grade 1 tumours and there was a significant difference in outcome for WHO/ISUP grades 2, 3 and 4. For Fuhrman grading the cancer-free survival was not significantly different for grade 2 and grade 3 tumours. On multivariate analysis WHO/ISUP grade and pT staging category were found to retain prognostic significance. The study demonstrates that FG cannot be applied in >20% of cases of ccRCC and the WHO/ISUP provides superior prognostic information. © 2017 John Wiley & Sons Ltd.
Designing of Holistic Mathematic Education Model Based-"System Among" at Low Grade Elementary School
NASA Astrophysics Data System (ADS)
Hayati, R.; Fauzan, A.; Iswari, M.; Khaidir, A.
2018-04-01
The purpose of this study was to develop a model of Holistic Mathematics Education (HME) among systems based on low-grade primary school students so that students have a solid foundation when entering a higher behavior. This type of research is desaign research developed by Plomp to have three stages, namely the preliminary research, development or prototyping phase, and assessement Phase. This research resulted in a model Holistic Mathematics Education (HME) -based system is among the primary school students low grade consists of 10 stages, namely 1) Recap through the neighborhood, 2) Discussion groups by exploiting the environment, 3) Demonstration Group, 4) Exercise individuals, 5) mathematical modeling, 6) Demonstration of individuals, 7) Reflections, 8) impressions and messages, and giving meaning, 9) Celebrations and 10) A thorough assessment. Furthermore, this model also produces 7 important components that should be developed teacher, namely 1) constructivism, 2) the nature of nature, 3) independence, 4) parable, 5) inquiry, 6) cooperation, and 7) strengthening. This model will produce a model in the form of books, student books and teacher's guide book as a support system that can help users in its application.
Babcock, Hazen P
2018-01-29
This work explores the use of industrial grade CMOS cameras for single molecule localization microscopy (SMLM). We show that industrial grade CMOS cameras approach the performance of scientific grade CMOS cameras at a fraction of the cost. This makes it more economically feasible to construct high-performance imaging systems with multiple cameras that are capable of a diversity of applications. In particular we demonstrate the use of industrial CMOS cameras for biplane, multiplane and spectrally resolved SMLM. We also provide open-source software for simultaneous control of multiple CMOS cameras and for the reduction of the movies that are acquired to super-resolution images.
Trachomatous Scar Ranking: A Novel Outcome for Trachoma Studies.
Baldwin, Angela; Ryner, Alexander M; Tadesse, Zerihun; Shiferaw, Ayalew; Callahan, Kelly; Fry, Dionna M; Zhou, Zhaoxia; Lietman, Thomas M; Keenan, Jeremy D
2017-06-01
AbstractWe evaluated a new trachoma scarring ranking system with potential use in clinical research. The upper right tarsal conjunctivas of 427 individuals from Ethiopian villages with hyperendemic trachoma were photographed. An expert grader first assigned a scar grade to each photograph using the 1981 World Health Organization (WHO) grading system. Then, all photographs were ranked from least (rank = 1) to most scarring (rank = 427). Photographic grading found 79 (18.5%) conjunctivae without scarring (C0), 191 (44.7%) with minimal scarring (C1), 105 (24.6%) with moderate scarring (C2), and 52 (12.2%) with severe scarring (C3). The ranking method demonstrated good internal validity, exhibiting a monotonic increase in the median rank across the levels of the 1981 WHO grading system. Intrarater repeatability was better for the ranking method (intraclass correlation coefficient = 0.84, 95% CI = 0.74-0.94). Exhibiting better internal and external validity, this ranking method may be useful for evaluating the difference in scarring between groups of individuals.
Performance analysis of a compact and low-cost mapping-grade mobile laser scanning system
NASA Astrophysics Data System (ADS)
Julge, Kalev; Vajakas, Toivo; Ellmann, Artu
2017-10-01
The performance of a low-cost, self-contained, compact, and easy to deploy mapping-grade mobile laser scanning (MLS) system, which is composed of a light detection and ranging sensor Velodyne VLP-16 and a dual antenna global navigation satellite system/inertial navigation system SBG Systems Ellipse-D, is analyzed. The field tests were carried out in car-mounted and backpack modes for surveying road engineering structures (such as roads, parking lots, underpasses, and tunnels) and coastal erosion zones, respectively. The impact of applied calculation principles on trajectory postprocessing, direct georeferencing, and the theoretical accuracy of the system is analyzed. A calibration method, based on Bound Optimization BY Quadratic Approximation, for finding the boresight angles of an MLS system is proposed. The resulting MLS point clouds are compared with high-accuracy static terrestrial laser scanning data and survey-grade MLS data from a commercially manufactured MLS system. The vertical, horizontal, and relative accuracy are assessed-the root-mean-square error (RMSE) values were determined to be 8, 15, and 3 cm, respectively. Thus, the achieved mapping-grade accuracy demonstrates that this relatively compact and inexpensive self-assembled MLS can be successfully used for surveying the geometry and deformations of terrain, buildings, road, and other engineering structures.
Grading system for blood vessel tumor emboli of invasive ductal carcinoma of the breast.
Sugiyama, Michiko; Hasebe, Takahiro; Shimada, Hiroko; Takeuchi, Hideki; Shimizu, Kyoko; Shimizu, Michio; Yasuda, Masanori; Ueda, Shigeto; Shigekawa, Takashi; Osaki, Akihiko; Saeki, Toshiaki
2015-06-01
We previously reported that the number of mitotic and apoptotic figures in tumor cells in blood vessel tumor emboli had the greatest significant power for the accurate prediction of the outcome of patients with invasive ductal carcinoma of the breast. The purpose of the present study was to devise a grading system for blood vessel tumor emboli based on the mitotic and apoptotic figures of tumor cells in blood vessel tumor emboli, enabling accurate prediction of the outcome of patients with invasive ductal carcinoma of the breast. We classified 263 invasive ductal carcinomas into the following 3 grades according to the numbers of mitotic and apoptotic figures in tumor cells located in blood vessels within 1 high-power field: grade 0, no blood vessel invasion; grade 1, absence of mitotic figures and presence of any number of apoptotic figures, or 1 mitotic figure and 0 to 2 apoptotic figures; and grade 2, 1 mitotic figure and 3 or more apoptotic figures, or 2 or more mitotic figures and 1 or more apoptotic figures. Multivariate analyses with well-known prognostic factors demonstrated that grade 2 blood vessel tumor emboli significantly increased the hazard ratios for tumor recurrence independent of the nodal status, pathological TNM stage, hormone receptor status, or HER2 status. The presently reported grading system for blood vessel tumor emboli is the strongest histologic factor for accurate prediction of the outcome of patients with invasive ductal carcinoma of the breast. Copyright © 2015 Elsevier Inc. All rights reserved.
Gu, Junxia; Liang, Yuting; Qiao, Longwei; Li, Xiaoyun; Li, Xingang; Lu, Yaojuan; Zheng, Qiping
2013-01-01
Multiple studies have recently demonstrated the oncogenic property of URI (or RMP, a member of the prefoldin family of molecular chaperones) during progression of hepatocellular carcinoma, ovarian cancer, and possibly prostate cancer. Most recently, we have shown that URI/RMP is up-regulated in cervical cancer, another reproductive system tumor beside ovarian and prostate cancers. To investigate if URI/RMP also plays a role in other reproductive system tumors, especially in endometrioid adenocarcinoma, we analyzed URI/RMP expression in a TMA (tissue microarray) containing tissues from 30 cases of endometrioid adenocarcinoma (which covers tumor tissues from Grade I through Grade III) and adjacent endometrium by immunohistochemistry (IHC) and densitometry analysis using image-pro plus 6.0 software. Our results showed that the mean density of URI/RMP expression in cancerous tissue is slightly higher than that of the adjacent endometrial tissue, though not statistically significant (p>0.05). There is no significant difference either between the mean density of Grade III cancerous tissue and that of Grade I and II cancers. Notably, we detected significantly higher signal intensity in cancerous tissue of all 7 Grade III cases than that of their adjacent endometrial tissue (p<0.05), suggesting a correlation of URI/RMP expression with the differentiation and pathological classification of endometrioid adenocarcinoma. Together, our results demonstrate the heterogeneous expression of URI/RMP in endometrioid adenocarcinoma. The higher level of URI/RMP expression in high-grade endometrioid adenocarcinomas compared to tissues of adjacent endometrium or gland suggests a diagnostic and possibly, a prognostic value of URI/RMP in endometrioid adenocarcinoma.
Gu, Junxia; Liang, Yuting; Qiao, Longwei; Li, Xiaoyun; Li, Xingang; Lu, Yaojuan; Zheng, Qiping
2013-01-01
Multiple studies have recently demonstrated the oncogenic property of URI (or RMP, a member of the prefoldin family of molecular chaperones) during progression of hepatocellular carcinoma, ovarian cancer, and possibly prostate cancer. Most recently, we have shown that URI/RMP is up-regulated in cervical cancer, another reproductive system tumor beside ovarian and prostate cancers. To investigate if URI/RMP also plays a role in other reproductive system tumors, especially in endometrioid adenocarcinoma, we analyzed URI/RMP expression in a TMA (tissue microarray) containing tissues from 30 cases of endometrioid adenocarcinoma (which covers tumor tissues from Grade I through Grade III) and adjacent endometrium by immunohistochemistry (IHC) and densitometry analysis using image-pro plus 6.0 software. Our results showed that the mean density of URI/RMP expression in cancerous tissue is slightly higher than that of the adjacent endometrial tissue, though not statistically significant (p>0.05). There is no significant difference either between the mean density of Grade III cancerous tissue and that of Grade I and II cancers. Notably, we detected significantly higher signal intensity in cancerous tissue of all 7 Grade III cases than that of their adjacent endometrial tissue (p<0.05), suggesting a correlation of URI/RMP expression with the differentiation and pathological classification of endometrioid adenocarcinoma. Together, our results demonstrate the heterogeneous expression of URI/RMP in endometrioid adenocarcinoma. The higher level of URI/RMP expression in high-grade endometrioid adenocarcinomas compared to tissues of adjacent endometrium or gland suggests a diagnostic and possibly, a prognostic value of URI/RMP in endometrioid adenocarcinoma. PMID:24228101
Interobserver reproducibility of The Paris System for Reporting Urinary Cytology.
Long, Theresa; Layfield, Lester J; Esebua, Magda; Frazier, Shellaine R; Giorgadze, D Tamar; Schmidt, Robert L
2017-01-01
The Paris System for Reporting Urinary Cytology represents a significant improvement in classification of urinary specimens. The system acknowledges the difficulty in cytologically diagnosing low-grade urothelial carcinomas and has developed categories to deal with this issue. The system uses six categories: unsatisfactory, negative for high-grade urothelial carcinoma (NHGUC), atypical urothelial cells, suspicious for high-grade urothelial carcinoma, high-grade urothelial carcinoma, other malignancies and a seventh subcategory (low-grade urothelial neoplasm). Three hundred and fifty-seven urine specimens were independently reviewed by four cytopathologists unaware of the previous diagnoses. Each cytopathologist rendered a diagnosis according to the Paris System categories. Agreement was assessed using absolute agreement and weighted chance-corrected agreement (kappa). Disagreements were classified as low impact and high impact based on the potential impact of a misclassification on clinical management. The average absolute agreement was 65% with an average expected agreement of 44%. The average chance-corrected agreement (kappa) was 0.32. Nine hundred and ninety-nine of 1902 comparisons between rater pairs were in agreement, but 12% of comparisons differed by two or more categories for the category NHGUC. Approximately 15% of the disagreements were classified as high clinical impact. Our findings indicated that the scheme recommended by the Paris System shows adequate precision for the category NHGUC, but the other categories demonstrated unacceptable interobserver variability. This low level of diagnostic precision may negatively impact the applicability of the Paris System for widespread clinical application.
Wangensteen, Arnlaug; Tol, Johannes L; Roemer, Frank W; Bahr, Roald; Dijkstra, H Paul; Crema, Michel D; Farooq, Abdulaziz; Guermazi, Ali
2017-04-01
To assess and compare the intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injury. Male athletes (n=40) with clinical diagnosis of acute hamstring injury and MRI ≤5days were selected from a prospective cohort. Two radiologists independently evaluated the MRIs using standardised scoring form including the modified Peetrons grading system, the Chan acute muscle strain injury classification and the British Athletics Muscle Injury Classification. Intra-and interrater reliability was assessed with linear weighted kappa (κ) or unweighted Cohen's κ and percentage agreement was calculated. We observed 'substantial' to 'almost perfect' intra- (κ range 0.65-1.00) and interrater reliability (κ range 0.77-1.00) with percentage agreement 83-100% and 88-100%, respectively, for severity gradings, overall anatomical sites and overall classifications for the three MRI systems. We observed substantial variability (κ range -0.05 to 1.00) for subcategories within the Chan classification and the British Athletics Muscle Injury Classification, however, the prevalence of positive scorings was low for some subcategories. The modified Peetrons grading system, overall Chan classification and overall British Athletics Muscle Injury Classification demonstrated 'substantial' to 'almost perfect' intra- and interrater reliability when scored by experienced radiologists. The intra- and interrater reliability for the anatomical subcategories within the classifications remains unclear. Copyright © 2017 Elsevier B.V. All rights reserved.
Location Based Services for Outdoor Ecological Learning System: Design and Implementation
ERIC Educational Resources Information Center
Hsiao, Hsien-Sheng; Lin, Chih-Cheng; Feng, Ruei-Ting; Li, Kun Jing
2010-01-01
This paper aimed to demonstrate how location-based services were implemented in ubiquitous outdoor ecological learning system. In an elementary school in northern Taiwan, two fifth grade classes on an ecology project were randomly selected: The experimental group could access the ecological learning system on hand-held devices while the control…
ERIC Educational Resources Information Center
HEATHERS, GLEN
DURING THE FIVE YEAR PERIOD, 1958-63, A DEMONSTRATION TEST OF THE DUAL PROGRESS PLAN WAS CONDUCTED IN GRADES 3 THROUGH 6 OF THE NINE ELEMENTARY SCHOOLS AND IN GRADES 7 AND 8 OF THE JUNIOR HIGH SCHOOLS IN LONG BEACH AND OSSINING, NEW YORK. RELATED TRYOUTS OF THE PLAN WERE MADE IN 14 OTHER SCHOOL SYSTEMS ACROSS THE COUNTRY. THE PLAN INVOLVES…
Contrast-enhanced ultrasonography for the evaluation of liver fibrosis after biliary obstruction.
Shin, Hyun Joo; Chang, Eun Young; Lee, Hye Sun; Hong, Jung Hwa; Park, Gyuri; Kim, Hyun Gi; Kim, Myung-Joon; Lee, Mi-Jung
2015-03-07
To investigate perfusion change in contrast-enhanced ultrasonography (CEUS) to evaluate liver fibrosis based on biliary obstruction using an animal model. New Zealand white rabbits (3-4 kg) underwent bile duct ligation to form a biliary obstruction model. We performed liver CEUS and laboratory tests on the day before the operation (day 0) and every 7 postoperative days until the rabbits were sacrificed. After CEUS, signal intensity of liver parenchyma with a time-intensity curve was analyzed. Perfusion parameters were automatically calculated from region-of-interests, including peak signal intensity, mean transit time, area under the curve and time to peak. Histological grades of liver fibrosis were assessed according to the Metavir score system immediately after sacrifice. Generalized estimating equations were used to analyze the association between liver fibrosis grades and perfusion parameters for statistical analysis. The perfusion parameters were measured on the last day and the difference between day 0 and the last day were evaluated. From the nine rabbits, histological grades of liver fibrosis were grade 1 in one rabbit, grade 2 and 3 in three rabbits each, and grade 4 in two rabbits. Among the four CEUS parameters, only the peak signal intensity measured on the last day demonstrated a significant association with liver fibrosis grades (OR = 1.392, 95%CI: 1.114-1.741, P = 0.004). The difference in peak signal intensity between day 0 and the last day also demonstrated an association with liver fibrosis (OR = 1.191, 95%CI: 0.999-1.419, P = 0.051). The other parameters tested, including mean transit time, area under the curve, and time to peak, showed no significant correlation with liver fibrosis grades. This animal study demonstrates that CEUS can be used to evaluate liver fibrosis from biliary obstruction using peak signal intensity as a parameter.
Steffens, Sandra; Janssen, Martin; Roos, Frederik C; Becker, Frank; Steinestel, Julie; Abbas, Mahmoud; Steinestel, Konrad; Wegener, Gerd; Siemer, Stefan; Thüroff, Joachim W; Hofmann, Rainer; Stöckle, Michael; Schrader, Mark; Hartmann, Arndt; Hasenfus, Andrea; Kuczyk, Markus A; Junker, Kerstin; Schrader, Andres J
2014-12-01
The prognostic value of the Fuhrman nuclear grading system has been questioned for chromophobe renal cell carcinoma (chRCC) because this subtype frequently displays nuclear and nucleolar pleomorphism. The present study reevaluates this grading system in a series of patients with nonsarcomatoid chRCC. We identified 176 patients (3.6%) with nonsarcomatoid chRCC in a total of 4897 patients who underwent surgery for renal cell carcinoma at 5 centers in Germany between 1990 and 2010. The mean follow-up was 51.1 months. The 3 groups (G1 versus G2 versus G3/4) were comparable in terms of age, sex, tumor diameter, and lymph node metastasis. They only differed significantly in tumor stage (P = .01) and the incidence of synchronous visceral metastasis (P = .04). The 5-year cancer-specific survival rates were 84.4% for G1 (n = 32), 84.3% for G2 (n = 108), and 74.1% for G3/4 tumors (n = 33) (P = .58). Accordingly, multivariate analysis including age, sex, tumor stage, and metastatic disease did not identify Fuhrman grading as an independent predictor of cancer-specific survival in patients with chRCC (P = .4). We were able to demonstrate in a large multicenter cohort that the Fuhrman grading system does not qualify as a prognostic tool in patients with chRCC. Copyright © 2014 Elsevier Inc. All rights reserved.
McWilliams, C.K.; Wintsch, R.P.; Kunk, Michael J.
2007-01-01
Detailed electron microprobe analyses of phyllosilicates in crenulated phyllites from south-eastern Vermont show that grain-scale zoning is common, and sympathetic zoning in adjacent minerals is nearly universal. We interpret this to reflect a pressure-solution mechanism for cleavage development, where precipitation from a very small fluid reservoir fractionated that fluid. Multiple analyses along single muscovite, biotite and chlorite grains (30–200 μm in length) show zoning patterns indicating Tschermakitic substitutions in muscovite and both Tschermakitic and di/trioctahedral substitutions in biotite and chlorite. Using cross-cutting relationships and mineral chemistry it is shown that these patterns persist in cleavages produced at metamorphic conditions of chlorite-grade, chlorite-grade overprinted by biotite-grade and biotite-grade. Zoning patterns are comparable in all three settings, requiring a similar cleavage-forming mechanism independent of metamorphic grade. Moreover, the use of 40Ar/39Ar geochronology demonstrates this is true regardless of age. Furthermore, samples with chlorite-grade cleavages overprinted by biotite porphyroblasts suggest the closure temperatures for the diffusion of Al, Si, Mg and Fe ions are greater than the temperature of the biotite isograd (>∼400 °C). Parallel and smoothly fanning tie lines produced by coexisting muscovite–chlorite, and muscovite–biotite pairs on compositional diagrams demonstrate effectively instantaneous chemical equilibrium and probably indicate simultaneous crystallization.These results do not support theories suggesting cleavages form in fluid-dominated systems. If crenulation cleavages formed in systems in which the chemical potentials of all major components are fixed by an external reservoir, then the compositions of individual grains defining these cleavages would be uniform. On the contrary, the fine-scale chemical zoning observed probably reflects a grain-scale process consistent with a pressure-solution mechanism in which the aqueous activities of major components are defined by local dissolution and precipitation. Thus the role of fluids was probably limited to one of catalysing pressure-solution and fluids apparently did not drive cleavage development.
Xiao, Di; Vignarajan, Janardhan; Chen, Tingting; Ye, Tiantian; Xiao, Baixiang; Congdon, Nathan; Kanagasingam, Yogessan
2017-12-01
We have developed a new telemedicine system for comprehensive eye examination, diabetic retinopathy (DR) screening, and eye disease diagnosis and treatment. The novel points of the system include a tablet application for facilitating doctor's examination and diagnosis process, a comprehensive eye examination component, and integrated treatment planning and recording. The system provided a new service model through one ophthalmological center linking with multiple remote and rural hospitals for eye care in Guangdong province, China. The early stage of the project study also undertook the responsibility of educations for remote-area doctors and image graders for DR grading and glaucoma grading and research on the effectiveness of short message service (SMS) reminder for patient revisit. Some other research, such as the comparison of the accuracy of graders' DR grading with the gold standard, and doctor's tentative diagnosis with final diagnosis and related statistical information, has been implemented in the system. In the preliminary practice, we summarized the outcomes related to presenting system performance and made an initial analysis. From the practice, the project has shown the telemedicine system and associated contents have satisfied our initial goal and demonstrated their effectiveness and efficiency.
Olsen, Timothy W.
2008-01-01
Purpose To establish a grading system of eye bank eyes using fundus autofluorescence (FAF) and identify a methodology that correlates FAF to age-related macular degeneration (AMD) with clinical correlation to the Age-Related Eye Disease Study (AREDS). Methods Two hundred sixty-two eye bank eyes were evaluated using a standardized analysis of FAF. Measurements were taken with the confocal scanning laser ophthalmoscope (cSLO). First, high-resolution, digital, stereoscopic, color images were obtained and graded according to AREDS criteria. With the neurosensory retina removed, mean FAF values were obtained from cSLO images using software analysis that excludes areas of atrophy and other artifact, generating an FAF value from a grading template. Age and AMD grade were compared to FAF values. An internal fluorescence reference standard was tested. Results Standardization of the cSLO machine demonstrated that reliable data could be acquired after a 1-hour warm-up. Images obtained prior to 1 hour had falsely elevated levels of FAF. In this initial analysis, there was no statistical correlation of age to mean FAF. There was a statistically significant decrease in FAF from AREDS grade 1, 2 to 3, 4 (P < .0001). An internal fluorescent standard may serve as a quantitative reference. Conclusions The Minnesota Grading System (MGS) of FAF (MGS-FAF) establishes a standardized methodology for grading eye bank tissue to quantify FAF compounds in the retinal pigment epithelium and correlate these findings to the AREDS. Future studies could then correlate specific FAF to the aging process, histopathology AMD phenotypes, and other maculopathies, as well as to analyze the biochemistry of autofluorescent fluorophores. PMID:19277247
Danawala, Zeeshan A; Singh, Dinesh
2015-05-01
To investigate the perioperative complication rates for paraplegic-quadriplegic patients (PQPs) undergoing percutaneous nephrolithotomy (PCNL) as compared with non-PQPs using a standardized method of complication reporting via the Clavien system. Two hundred thirteen consecutive PCNLs performed by a single surgeon were analyzed. There were 31 and 115 patients separated into PQP and non-PQP groups, respectively. Data collection included demographic and clinical factors, as well as perioperative and delayed complications. Complications were organized by the Clavien grade. All- and initial-procedure complications were analyzed. The rate of adverse events for each Clavien grade was calculated, and statistical comparisons were made. The relationship between PQP and complication severity was investigated using univariate and multivariate analyses. There were 38 and 43 initial-procedure complications in the PQP and non-PQP groups, respectively. The rate of adverse events was higher across the spectrum of Clavien grades for the PQP group, specifically grade 1 (48.4% vs 20.2%; P = .002), grade 2 (22.6% vs 5.3%; P = .004), grade 3b (12.9% vs 2.6%; P = .038), grade 4a (6.5% vs 0%), and grade 4b (9.7% vs 1.8%; P = .066). Approximately 51.6% and 31.5% of PQPs and non-PQPs experienced ≥ 1 complications, respectively (odds ratio = 2.34; P = .05). Multivariate analysis demonstrated paraplegia or quadriplegia status to be an independent risk factor for the development of perioperative complications after adjusting for confounding factors (odds ratio = 2.91; P = .040). PCNL complication rates are higher in PQPs compared with non-PQPs. This study is one of the first in PCNL to use a standardized reporting system to highlight high-risk individuals within the stone population. Copyright © 2015 Elsevier Inc. All rights reserved.
Olsen, Timothy W
2008-01-01
To establish a grading system of eye bank eyes using fundus autofluorescence (FAF) and identify a methodology that correlates FAF to age-related macular degeneration (AMD) with clinical correlation to the Age-Related Eye Disease Study (AREDS). Two hundred sixty-two eye bank eyes were evaluated using a standardized analysis of FAF. Measurements were taken with the confocal scanning laser ophthalmoscope (cSLO). First, high-resolution, digital, stereoscopic, color images were obtained and graded according to AREDS criteria. With the neurosensory retina removed, mean FAF values were obtained from cSLO images using software analysis that excludes areas of atrophy and other artifact, generating an FAF value from a grading template. Age and AMD grade were compared to FAF values. An internal fluorescence reference standard was tested. Standardization of the cSLO machine demonstrated that reliable data could be acquired after a 1-hour warm-up. Images obtained prior to 1 hour had falsely elevated levels of FAF. In this initial analysis, there was no statistical correlation of age to mean FAF. There was a statistically significant decrease in FAF from AREDS grade 1, 2 to 3, 4 (P < .0001). An internal fluorescent standard may serve as a quantitative reference. The Minnesota Grading System (MGS) of FAF (MGS-FAF) establishes a standardized methodology for grading eye bank tissue to quantify FAF compounds in the retinal pigment epithelium and correlate these findings to the AREDS. Future studies could then correlate specific FAF to the aging process, histopathology AMD phenotypes, and other maculopathies, as well as to analyze the biochemistry of autofluorescent fluorophores.
Black blood MRI in suspected large artery primary angiitis of the central nervous system.
Pfefferkorn, Thomas; Linn, Jennifer; Habs, Maximilian; Opherk, Christina; Cyran, Clemens; Ottomeyer, Caroline; Straube, Andreas; Dichgans, Martin; Nikolaou, Konstantin; Saam, Tobias
2013-07-01
Single case reports suggest that black blood MRI (T1-weighted fat and blood suppressed sequences with and without contrast injection; BB-MRI) may visualize intracranial vessel wall contrast enhancement (CE) in primary angiitis of the central nervous system (PACNS). In this single-center observational pilot study we prospectively investigated the value of BB-MRI in the diagnosis of large artery PACNS. Patients with suspected large artery PACNS received a standardized diagnostic program including BB-MRI. Vessel wall CE was graded (grade 0-2) by two experienced readers blinded to clinical data and correlated to the final diagnosis. Four of 12 included patients received a final diagnosis of PACNS. All of them showed moderate (grade 1) to strong (grade 2) vessel wall CE at the sites of stenosis. A moderate (grade 1) vessel wall CE grade was also observed in 6 of the remaining 8 patients in whom alternative diagnoses were made: arteriosclerotic disease (n = 4), intracranial dissection (n = 1), and Moyamoya disease (n = 1). Our pilot study demonstrates that vessel wall CE is a frequent finding in PACNS and its mimics. Larger trials will be necessary to evaluate the utility of BB-MRI in the diagnostic workup of PACNS. Copyright © 2012 by the American Society of Neuroimaging.
Keenan, S J; Diamond, J; McCluggage, W G; Bharucha, H; Thompson, D; Bartels, P H; Hamilton, P W
2000-11-01
The histological grading of cervical intraepithelial neoplasia (CIN) remains subjective, resulting in inter- and intra-observer variation and poor reproducibility in the grading of cervical lesions. This study has attempted to develop an objective grading system using automated machine vision. The architectural features of cervical squamous epithelium are quantitatively analysed using a combination of computerized digital image processing and Delaunay triangulation analysis; 230 images digitally captured from cases previously classified by a gynaecological pathologist included normal cervical squamous epithelium (n=30), koilocytosis (n=46), CIN 1 (n=52), CIN 2 (n=56), and CIN 3 (n=46). Intra- and inter-observer variation had kappa values of 0.502 and 0.415, respectively. A machine vision system was developed in KS400 macro programming language to segment and mark the centres of all nuclei within the epithelium. By object-oriented analysis of image components, the positional information of nuclei was used to construct a Delaunay triangulation mesh. Each mesh was analysed to compute triangle dimensions including the mean triangle area, the mean triangle edge length, and the number of triangles per unit area, giving an individual quantitative profile of measurements for each case. Discriminant analysis of the geometric data revealed the significant discriminatory variables from which a classification score was derived. The scoring system distinguished between normal and CIN 3 in 98.7% of cases and between koilocytosis and CIN 1 in 76.5% of cases, but only 62.3% of the CIN cases were classified into the correct group, with the CIN 2 group showing the highest rate of misclassification. Graphical plots of triangulation data demonstrated the continuum of morphological change from normal squamous epithelium to the highest grade of CIN, with overlapping of the groups originally defined by the pathologists. This study shows that automated location of nuclei in cervical biopsies using computerized image analysis is possible. Analysis of positional information enables quantitative evaluation of architectural features in CIN using Delaunay triangulation meshes, which is effective in the objective classification of CIN. This demonstrates the future potential of automated machine vision systems in diagnostic histopathology. Copyright 2000 John Wiley & Sons, Ltd.
Hernandez, Matthew C; Aho, Johnathon M; Habermann, Elizabeth B; Choudhry, Asad J; Morris, David S; Zielinski, Martin D
2017-01-01
Determination and reporting of disease severity in emergency general surgery lacks standardization. Recently, the American Association for the Surgery of Trauma (AAST) proposed an anatomic severity grading system. We aimed to validate this system in patients with appendicitis and determine if cross-sectional imaging correlates with disease severity at operation. Patients 18 years or older undergoing treatment for acute appendicitis between 2013 and 2015 were identified. Baseline demographics, procedure types were recorded, and AAST grades were assigned based on intraoperative and radiologic findings. Outcomes including length of stay, 30-day mortality, and complications based on Clavien-Dindo categories and National Surgical Quality Improvement Program variables. Summary statistical univariate, nominal logistic, and standard least squares analyses were performed comparing AAST grade with key outcomes. Bland-Altman analysis compared operative findings with preoperative cross-sectional imaging to compare assigning grades. Three hundred thirty-four patients with mean (±SD) age of 39.3 years (±16.5) were included (53% men), and all patients had cross-sectional imaging. Two hundred ninety-nine underwent appendectomy, and 85% completed laparoscopic. Thirty-day mortality rate was 0.9%, complication rate was 21%. Increased (median [interquartile range, IQR]) AAST grade was recorded in patients with complications (2 [1-4]) compared with those without (1 [1-1], p = 0.001). For operative management, (median [IQR]) AAST grades were significantly associated with procedure type: laparoscopic (1 [1-1]), open (4 [2-5]), conversion to open (3 [1-4], p = 0.001). Increased (median [IQR]) AAST grades were significantly associated in nonoperative management: patients having a complication had a higher median AAST grade (4 [3-5]) compared with those without (3 [2-3], p = 0.001). Bland-Altman analysis comparing AAST grade and cross-sectional imaging demonstrated no difference (-0.02 ± 0.02; p = 0.2; coefficient of repeatability 0.9). The AAST grading system is valid in our population. Increased AAST grade is associated with open procedures, complications, and length of stay. The AAST emergency general surgery grade determined by preoperative imaging strongly correlated to operative findings. Epidemiologic/prognostic study, level III.
Hernandez, Matthew; Aho, Johnathan M.; Habermann, Elizabeth B.; Choudhry, Asad; Morris, David; Zielinski, Martin
2016-01-01
Background Determination and reporting of disease severity in emergency general surgery (EGS) lacks standardization. Recently, the American Association for the Surgery of Trauma (AAST) proposed an anatomic severity grading system. We aimed to validate this system in patients with appendicitis, and determine if cross sectional imaging correlates with disease severity at operation. Methods Patients 18 years or older undergoing treatment for acute appendicitis between 2013 and 2015 were identified. Baseline demographics, procedure types were recorded, and AAST grades were assigned based on intraoperative and radiologic findings. Outcomes including length of stay, 30 day mortality, and complications based on Clavien-Dindo categories and National Surgical Quality Improvement Program variables. Summary statistical univariate, nominal logistic and standard least squares analyses were performed comparing AAST grade with key outcomes. Bland-Altman analysis compared operative findings to preoperative cross sectional imaging to compare assigning grades. Results 334 patients with mean (±SD) age of 39.3 years (±16.5) were included (53% male) and all patients had cross sectional imaging. 299 underwent appendectomy, and 85% completed laparoscopic. 30 day mortality rate was 0.9%, complication rate 21%. Increased median [IQR] AAST grade was recorded in patients with complications 2 [1-4] compared to those without 1 [1-1], p=0.001. For operative management, a median [IQR] AAST grades were significantly associated with procedure type: laparoscopic 1 [1-1], open 4 [2-5] conversion to open 3 [1-4], p=0.001. Increased median [IQR] AAST grades were significantly associated in non-operative management: patients having a complication had a higher median AAST grade of 4 [3-5], compared to those without 3 [2-3], p=0.001. Bland Altman analysis comparing AAST grade and cross sectional imaging demonstrated no difference; −0.02 ±0.02 p = 0.2 coefficient of repeatability 0.9. Conclusions The AAST grading system is valid in our population. Increased AAST grade is associated with open procedures, complications, and length of stay. AAST EGS grade determined by preoperative imaging strongly correlated to operative findings. PMID:27805996
Broadband locally resonant metamaterials with graded hierarchical architecture
NASA Astrophysics Data System (ADS)
Liu, Chenchen; Reina, Celia
2018-03-01
We investigate the effect of hierarchical designs on the bandgap structure of periodic lattice systems with inner resonators. A detailed parameter study reveals various interesting features of structures with two levels of hierarchy as compared with one level systems with identical static mass. In particular: (i) their overall bandwidth is approximately equal, yet bounded above by the bandwidth of the single-resonator system; (ii) the number of bandgaps increases with the level of hierarchy; and (iii) the spectrum of bandgap frequencies is also enlarged. Taking advantage of these features, we propose graded hierarchical structures with ultra-broadband properties. These designs are validated over analogous continuum models via finite element simulations, demonstrating their capability to overcome the bandwidth narrowness that is typical of resonant metamaterials.
Ueda, Toshihiko; Suzumura, Hirotaka; Johnstone, Murray; Uda, Shigekazu; Yoshida, Kazuhide
2018-06-01
To develop a grading system that provides objective quantification of flow through the conventional aqueous humor outflow (AHO) system. The technique gives clinicians an additional assessment option in the evaluation of glaucoma treatment approaches. This was a retrospective observational study. This study evaluated the eyes of all primary open-angle glaucoma patients who underwent a Trabectome (NeoMedix Corp., Tustin, CA, USA) procedure with or without cataract surgery in the interval between April and September 2016 (n = 73). The nasal hemisphere was divided into three regions. Utilizing a four-level grading system designed for this study, an aqueous humor outflow grade (G0-G3) was assigned to each region using a video taken during examinations. The individual grade levels of the three regions were combined to get a composite AHO score. The correlation between the composite AHO score and intraocular pressure (IOP) was then analyzed. Additionally, the speed of red blood cell (RBC) clusters in the episcleral veins (ESV) was calculated when made possible by the existence of pulsatile flow. At 3 months following the Trabectome procedure, average IOP decreased from 26 to 15 mmHg. Assessment of the relationship between AHO grade and IOP demonstrated that a high composite AHO score was correlated with lowered IOP (Tukey-Kramer method p < 0.05). Additionally, it was found that if one of the three regions had an AHO grade of ≥ G2, an IOP of < 20 mmHg could be predicted. (Fischer's exact test p < 0.0001). Calculated speed was as follows: at G1, the speed was 0.68 ± 0.26 mm/s (n = 7), at G2, the speed was 1.8 ± 0.84 mm/s (n = 5), and at G3, the speed was 6.8 ± 3.3 mm/s (n = 6). There was a significant correlation between an increase in the composite AHO score and a decrease in IOP. Additionally, the speed of RBC clusters as they traveled through the ESVs remained consistent for each of the grades, and the span of the speeds from lower to higher grades represented a significant range. These findings suggest that the grading system is a reliable measure of AHO. UMIN 000031745.
Charging-free electrochemical system for harvesting low-grade thermal energy
Yang, Yuan; Lee, Seok Woo; Ghasemi, Hadi; Loomis, James; Li, Xiaobo; Kraemer, Daniel; Zheng, Guangyuan; Cui, Yi; Chen, Gang
2014-01-01
Efficient and low-cost systems are needed to harvest the tremendous amount of energy stored in low-grade heat sources (<100 °C). Thermally regenerative electrochemical cycle (TREC) is an attractive approach which uses the temperature dependence of electrochemical cell voltage to construct a thermodynamic cycle for direct heat-to-electricity conversion. By varying temperature, an electrochemical cell is charged at a lower voltage than discharge, converting thermal energy to electricity. Most TREC systems still require external electricity for charging, which complicates system designs and limits their applications. Here, we demonstrate a charging-free TREC consisting of an inexpensive soluble Fe(CN)63−/4− redox pair and solid Prussian blue particles as active materials for the two electrodes. In this system, the spontaneous directions of the full-cell reaction are opposite at low and high temperatures. Therefore, the two electrochemical processes at both low and high temperatures in a cycle are discharge. Heat-to-electricity conversion efficiency of 2.0% can be reached for the TREC operating between 20 and 60 °C. This charging-free TREC system may have potential application for harvesting low-grade heat from the environment, especially in remote areas. PMID:25404325
ERIC Educational Resources Information Center
Archer, Chalmers, Jr.; Archer, A. J. Finch
1986-01-01
Examines the susceptibility of computerized institutional records to security violations by "hackers," wishing to change grades/records or merely demonstrate their ability to access the systems. Points to practices that encourage security abuses and risk confidentiality. Outlines procedures used by Northern Virginia Community College to…
Phase Separation in Lean Grade Duplex Stainless Steel 2101
Garfinkel, D.; Poplawsky, Jonathan D.; Guo, Wei; ...
2015-08-19
The use of duplex stainless steels (DSS) in nuclear power generation systems is limited by thermal instability that leads to embrittlement in the temperature range of 204°C - 538°C. New lean grade alloys, such as 2101, offer the potential to mitigate these effects. Thermal embrittlement was quantified through impact toughness and hardness testing on samples of alloy 2101 after aging at 427°C for various durations (1-10,000 hours). Additionally, atom probe tomography (APT) was utilized in order to observe the kinetics of α-α’ separation and G-phase formation. Mechanical testing and APT data for two other DSS alloys, 2003 and 2205 weremore » used as a reference to 2101. The results show that alloy 2101 exhibits superior performance compared to the standard grade DSS alloy, 2205, but inferior to the lean grade alloy, 2003, in mechanical testing. APT data demonstrates that the degree of α-α’ separation found in alloy 2101 closely resembles that of 2205, and greatly exceeds 2003. Additionally, contrary to what was observed in 2003, 2101 demonstrated G-phase like precipitates after long aging times, though precipitates were not as abundant as was observed in 2205.« less
Olsen, Timothy W; Bottini, Alexander R; Mendoza, Pia; Grossniklausk, Hans E
2015-09-01
To describe the histopathologic findings of the four stages of age-related macular degeneration (AMD) as defined by the Age-Related Eye Disease Study (AREDS) using the Minnesota grading system (MGS). There are no animal models for AMD. Eye banks enable access to human tissue with AMD. The level of AMD (grades 1 through 4) as defined by AREDS is determined ex vivo using the MGS. The AREDS has the largest collection to date of prospectively gathered data on the natural history of AMD. Since the MGS uses the same clinical criteria as AREDS, the addition of histopathologic findings of graded tissue confirms important pathophysiology at each stage of AMD. Four eye bank eyes were graded according to the MGS. Only the right eyes were dissected for phenotype grading. The fellow (left) eyes were fixed for histopathologic study. The eyes were serially sectioned (7 μm) through the macula. Individual slides were examined, and a two-dimensional reconstruction of the topography of the macula was created for each donor. Selected, unstained slides were used for immunohistochemical staining. In one donor, portions of tissue were obtained for transmission electron microscopic (TEM) processing. Donor 1 had a rare hard, nodular druse (MGS1). Donor 2 had intermediate confluent drusen (MGS2). Donor 3 had numerous intermediate drusen (MGS3) in the right eye. Histopathology of the fellow left showed basal laminar deposits (BLamD), soft drusen, and an area of occult choroidal neovascularization underlying the retinal pigment epithelium (RPE) with endothelial cells (CD31-positive). Donor 4 also had MGS 3 along with reticular pseudodrusen (RPD). Histologic and TEM examination demonstrated diffuse BLamD, thickening of Bruch's membrane, hard drusen, and focal nodules underlying the RPE that corresponded to the RPD. EM examination demonstrated both BLamD and electron-dense material located just external to the elastic layer of Bruch's membrane. Eye bank eyes graded using the MGS serve as an important link to the phenotypic and epidemiologic data from the AREDS. Thus, the MGS serves as a system to study the histopathology at each stage of AMD to better understand the relevant pathophysiologic changes in disease progression.
Olsen, Timothy W.; Bottini, Alexander R.; Mendoza, Pia; Grossniklausk, Hans E.
2015-01-01
Purpose To describe the histopathologic findings of the four stages of age-related macular degeneration (AMD) as defined by the Age-Related Eye Disease Study (AREDS) using the Minnesota grading system (MGS). Clinical Relevance There are no animal models for AMD. Eye banks enable access to human tissue with AMD. The level of AMD (grades 1 through 4) as defined by AREDS is determined ex vivo using the MGS. The AREDS has the largest collection to date of prospectively gathered data on the natural history of AMD. Since the MGS uses the same clinical criteria as AREDS, the addition of histopathologic findings of graded tissue confirms important pathophysiology at each stage of AMD. Methods Four eye bank eyes were graded according to the MGS. Only the right eyes were dissected for phenotype grading. The fellow (left) eyes were fixed for histopathologic study. The eyes were serially sectioned (7 μm) through the macula. Individual slides were examined, and a two-dimensional reconstruction of the topography of the macula was created for each donor. Selected, unstained slides were used for immunohistochemical staining. In one donor, portions of tissue were obtained for transmission electron microscopic (TEM) processing. Results Donor 1 had a rare hard, nodular druse (MGS1). Donor 2 had intermediate confluent drusen (MGS2). Donor 3 had numerous intermediate drusen (MGS3) in the right eye. Histopathology of the fellow left showed basal laminar deposits (BLamD), soft drusen, and an area of occult choroidal neovascularization underlying the retinal pigment epithelium (RPE) with endothelial cells (CD31-positive). Donor 4 also had MGS 3 along with reticular pseudodrusen (RPD). Histologic and TEM examination demonstrated diffuse BLamD, thickening of Bruch’s membrane, hard drusen, and focal nodules underlying the RPE that corresponded to the RPD. EM examination demonstrated both BLamD and electron-dense material located just external to the elastic layer of Bruch’s membrane. Conclusion Eye bank eyes graded using the MGS serve as an important link to the phenotypic and epidemiologic data from the AREDS. Thus, the MGS serves as a system to study the histopathology at each stage of AMD to better understand the relevant pathophysiologic changes in disease progression. PMID:27895380
DOT National Transportation Integrated Search
2001-02-01
The Minnesota data system includes the following basic files: Accident data (Accident File, Vehicle File, Occupant File); Roadlog File; Reference Post File; Traffic File; Intersection File; Bridge (Structures) File; and RR Grade Crossing File. For ea...
Using Technology and Assessment to Personalize Instruction: Preventing Reading Problems.
Connor, Carol McDonald
2017-09-15
Children who fail to learn to read proficiently are at serious risk of referral to special education, grade retention, dropping out of high school, and entering the juvenile justice system. Accumulating research suggests that instruction regimes that rely on assessment to inform instruction are effective in improving the implementation of personalized instruction and, in turn, student learning. However, teachers find it difficult to interpret assessment results in a way that optimizes learning opportunities for all of the students in their classrooms. This article focuses on the use of language, decoding, and comprehension assessments to develop personalized plans of literacy instruction for students from kindergarten through third grade, and A2i technology designed to support teachers' use of assessment to guide instruction. Results of seven randomized controlled trials demonstrate that personalized literacy instruction is more effective than traditional instruction, and that sustained implementation of personalized literacy instruction first through third grade may prevent the development of serious reading problems. We found effect sizes from .2 to .4 per school year, which translates into about a 2-month advantage. These effects accumulated from first through third grade with a large effect size (d = .7) equivalent to a full grade-equivalent advantage on standardize tests of literacy. These results demonstrate the efficacy of technology-supported personalized data-driven literacy instruction to prevent serious reading difficulties. Implications for translational prevention research in education and healthcare are discussed.
Lynn, Scott K.; Watkins, Casey M.; Wong, Megan A.; Balfany, Katherine; Feeney, Daniel F.
2018-01-01
The Athos ® wearable system integrates surface electromyography (sEMG ) electrodes into the construction of compression athletic apparel. The Athos system reduces the complexity and increases the portability of collecting EMG data and provides processed data to the end user. The objective of the study was to determine the reliability and validity of Athos as compared with a research grade sEMG system. Twelve healthy subjects performed 7 trials on separate days (1 baseline trial and 6 repeated trials). In each trial subjects wore the wearable sEMG system and had a research grade sEMG system’s electrodes placed just distal on the same muscle, as close as possible to the wearable system’s electrodes. The muscles tested were the vastus lateralis (VL), vastus medialis (VM), and biceps femoris (BF). All testing was done on an isokinetic dynamometer. Baseline testing involved performing isometric 1 repetition maximum tests for the knee extensors and flexors and three repetitions of concentric-concentric knee flexion and extension at MVC for each testing speed: 60, 180, and 300 deg/sec. Repeated trials 2-7 each comprised 9 sets where each set included three repetitions of concentric-concentric knee flexion-extension. Each repeated trial (2-7) comprised one set at each speed and percent MVC (50%, 75%, 100%) combination. The wearable system and research grade sEMG data were processed using the same methods and aligned in time. The amplitude metrics calculated from the sEMG for each repetition were the peak amplitude, sum of the linear envelope, and 95th percentile. Validity results comprise two main findings. First, there is not a significant effect of system (Athos or research grade system) on the repetition amplitude metrics (95%, peak, or sum). Second, the relationship between torque and sEMG is not significantly different between Athos and the research grade system. For reliability testing, the variation across trials and averaged across speeds was 0.8%, 7.3%, and 0.2% higher for Athos from BF, VL and VM, respectively. Also, using the standard deviation of the MVC normalized repetition amplitude, the research grade system showed 10.7% variability while Athos showed 12%. The wearable technology (Athos) provides sEMG measures that are consistent with controlled, research grade technologies and data collection procedures. Key points Surface EMG embedded into athletic garments (Athos) had similar validity and reliability when compared with a research grade system There was no difference in the torque-EMG relationship between the two systems No statistically significant difference in reliability across 6 trials between the two systems The validity and reliability of Athos demonstrates the potential for sEMG to be applied in dynamic rehabilitation and sports settings PMID:29769821
A lumber grading system for the future: an update evaluation
D. Earl Kline; Chris Surak; Philip A. Araman
2000-01-01
Virginia Tech and the Southern Research Station of the USDA Forest Service have jointly developed and refined a multiple-sensor lumber-scanning prototype to demonstrate and test applicable scanning technologies (Conners et al. 1997, Kline et al. 1997, Kline et al. 1998). This R&D effort has led to a patented wood color and grain sorting system (Conners and Lu 1998...
ERIC Educational Resources Information Center
Lytle, Rebecca; Todd, Teri
2009-01-01
Shane, who is in Ms. Jones's third-grade class, has autism. Ms. Jones has provided him with a schedule, a picture communication system, and a positive reinforcement system for his learning tasks. He is demonstrating progress toward his individualized education program (IEP) goals, but he still struggles with attending for any length of time,…
ERIC Educational Resources Information Center
Lin, Ming-Chao; Tutwiler, M. Shane; Chang, Chun-Yen
2011-01-01
This study investigated the relationship between the use of a three-dimensional Virtual Reality Learning Environment for Field Trip (3DVLE[subscript (ft)]) system and the achievement levels of senior high school earth science students. The 3DVLE[subscript (ft)] system was presented in two separate formats: Teacher Demonstrated Based and Student…
Drifting Recovery Base Concept for GEO Derelict Object Capture
NASA Technical Reports Server (NTRS)
Bacon, John B.
2009-01-01
Over 250 objects hover within 6 m/sec of perfect geostationary orbit. Over half of these objects lie within 0.1 m/sec of the GEO velocity. Such items have 62% of the total velocity required to achieve Earth gravitational escape. A conceptual architecture is proposed to clean this orbit area of derelict objects while providing a demonstration mission for many facets of future asteroid mining operations. These near-GEO objects average nearly 2000kg each, consisting of (typically functioning) power systems, batteries, and large quantities of components and raw aerospace-grade refined materials. Such a demonstration collection system could capture, collect and remove all GEO derelict objects in an international effort to create a depot of components and of aerospace-grade raw materials--with a total mass greater than that of the International Space Station--as a space scrap depot ready for transfer to lunar or Mars orbit, using only two heavy-lift launches and 2-3 years of on-orbit operations.
Deppe, Olaf; Dorner, Georg; König, Stefan; Martin, Tim; Voigt, Sven; Zimmermann, Steffen
2017-01-01
In the following paper, we present an industry perspective of inertial sensors for navigation purposes driven by applications and customer needs. Microelectromechanical system (MEMS) inertial sensors have revolutionized consumer, automotive, and industrial applications and they have started to fulfill the high end tactical grade performance requirements of hybrid navigation systems on a series production scale. The Fiber Optic Gyroscope (FOG) technology, on the other hand, is further pushed into the near navigation grade performance region and beyond. Each technology has its special pros and cons making it more or less suitable for specific applications. In our overview paper, we present latest improvements at NG LITEF in tactical and navigation grade MEMS accelerometers, MEMS gyroscopes, and Fiber Optic Gyroscopes, based on our long-term experience in the field. We demonstrate how accelerometer performance has improved by switching from wet etching to deep reactive ion etching (DRIE) technology. For MEMS gyroscopes, we show that better than 1°/h series production devices are within reach, and for FOGs we present how limitations in noise performance were overcome by signal processing. The paper also intends a comparison of the different technologies, emphasizing suitability for different navigation applications, thus providing guidance to system engineers. PMID:28287483
A Food-Grade Cloning System for Industrial Strains of Lactococcus lactis
Sørensen, Kim I.; Larsen, Rasmus; Kibenich, Annette; Junge, Mette P.; Johansen, Eric
2000-01-01
We have previously reported the construction of a food-grade cloning vector for Lactococcus using the ochre suppressor, supB, as the selective marker. This vector, pFG1, causes only a slight growth inhibition in the laboratory strain MG1363 but is unstable in the industrial strains tested. As supB suppresses both amber and ochre stop codons, which are present in 82% of all known lactococcal genes, this undesirable finding may result from the accumulation of elongated mistranslated polypeptides. Here, we report the development of a new food-grade cloning vector, pFG200, which is suitable for overexpressing a variety of genes in industrial strains of Lactococcus lactis. The vector uses an amber suppressor, supD, as selectable marker and consists entirely of Lactococcus DNA, with the exception of a small polylinker region. Using suppressible pyrimidine auxotrophs, selection and maintenance are efficient in any pyrimidine-free medium including milk. Importantly, the presence of this vector in a variety of industrial strains has no significant effect on the growth rate or the rate of acidification in milk, making this an ideal system for food-grade modification of industrially relevant L. lactis strains. The usefulness of this system is demonstrated by overexpressing the pepN gene in a number of industrial backgrounds. PMID:10742196
Evaluation of Urinary Tract Dilation Classification System for Grading Postnatal Hydronephrosis.
Hodhod, Amr; Capolicchio, John-Paul; Jednak, Roman; El-Sherif, Eid; El-Doray, Abd El-Alim; El-Sherbiny, Mohamed
2016-03-01
We assessed the reliability and validity of the Urinary Tract Dilation classification system as a new grading system for postnatal hydronephrosis. We retrospectively reviewed charts of patients who presented with hydronephrosis from 2008 to 2013. We included patients diagnosed prenatally and those with hydronephrosis discovered incidentally during the first year of life. We excluded cases involving urinary tract infection, neurogenic bladder and chromosomal anomalies, those associated with extraurinary congenital malformations and those with followup of less than 24 months without resolution. Hydronephrosis was graded postnatally using the Society for Fetal Urology system, and then the management protocol was chosen. All units were regraded using the Urinary Tract Dilation classification system and compared to the Society for Fetal Urology system to assess reliability. Univariate and multivariate analyses were performed to assess the validity of the Urinary Tract Dilation classification system in predicting hydronephrosis resolution and surgical intervention. A total of 490 patients (730 renal units) were eligible to participate. The Urinary Tract Dilation classification system was reliable in the assessment of hydronephrosis (parallel forms 0.92). Hydronephrosis resolved in 357 units (49%), and 86 units (12%) were managed by surgical intervention. The remainder of renal units demonstrated stable or improved hydronephrosis. Multivariate analysis revealed that the likelihood of surgical intervention was predicted independently by Urinary Tract Dilation classification system risk group, while Society for Fetal Urology grades were predictive of likelihood of resolution. The Urinary Tract Dilation classification system is reliable for evaluation of postnatal hydronephrosis and is valid in predicting surgical intervention. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Neuroprosthetic-enabled control of graded arm muscle contraction in a paralyzed human.
Friedenberg, David A; Schwemmer, Michael A; Landgraf, Andrew J; Annetta, Nicholas V; Bockbrader, Marcia A; Bouton, Chad E; Zhang, Mingming; Rezai, Ali R; Mysiw, W Jerry; Bresler, Herbert S; Sharma, Gaurav
2017-08-21
Neuroprosthetics that combine a brain computer interface (BCI) with functional electrical stimulation (FES) can restore voluntary control of a patients' own paralyzed limbs. To date, human studies have demonstrated an "all-or-none" type of control for a fixed number of pre-determined states, like hand-open and hand-closed. To be practical for everyday use, a BCI-FES system should enable smooth control of limb movements through a continuum of states and generate situationally appropriate, graded muscle contractions. Crucially, this functionality will allow users of BCI-FES neuroprosthetics to manipulate objects of different sizes and weights without dropping or crushing them. In this study, we present the first evidence that using a BCI-FES system, a human with tetraplegia can regain volitional, graded control of muscle contraction in his paralyzed limb. In addition, we show the critical ability of the system to generalize beyond training states and accurately generate wrist flexion states that are intermediate to training levels. These innovations provide the groundwork for enabling enhanced and more natural fine motor control of paralyzed limbs by BCI-FES neuroprosthetics.
NASA Astrophysics Data System (ADS)
Reed, Krystal Astra
The "Advancement via Individual Determination (AVID) program was designed to provide resources and strategies that enable underrepresented minority students to attend 4-year colleges" (AVID Center, 2013, p. 2). These students are characterized as the forgotten middle in that they have high test scores, average-to-low grades, minority or low socioeconomic status, and will be first-generation college students (AVID, 2011). Research indicates (Huerta, Watt, & Butcher, 2013) that strict adherence to 11 program components supports success of students enrolled in AVID, and AVID certification depends on districts following those components. Several studies (AVID Center, 2013) have investigated claims about the AVID program through qualitative analyses; however, very few have addressed this program quantitatively. This researcher sought to determine whether differences existed between student achievement and attendance rates between AVID and non-AVID middle schools. To achieve this goal, the researcher compared eighth-grade science and seventh- and eighth-grade mathematics scores from the 2007 to 2011 Texas Assessment of Knowledge and Skills (TAKS) and overall attendance rates in demographically equivalent AVID and non-AVID middle schools. Academic Excellence Indicator System (AEIS) reports from the Texas Education Agency (TEA) were used to obtain 2007 to 2011 TAKS results and attendance information for the selected schools. The results indicated a statistically significant difference between AVID demonstration students and non-AVID students in schools with similar CI. No statistically significant differences were found on any component of the TAKS for AVID economically disadvantaged students. The mean scores indicated an achievement gap between non-AVID and AVID demonstration middle schools. The findings from the other three research questions indicated no statistically significant differences between AVID and non-AVID student passing rates on the seventh- and eighth-grade TAKS math tests or on overall attendance rates. The mean scores on the eighth-grade TAKS science test revealed some positive results in the academic performance of economically disadvantaged in non-AVID demonstration middle schools. Specifically, the results indicated that the mean passing percentage of AVID demonstration was lower than that of non-AVID middle schools. The TAKS scores showed a small achievement gap between non-AVID and AVID demonstration middle schools.
Science for Iowa Schools, Grades 4-6.
ERIC Educational Resources Information Center
Nice, Karl; And Others
This guide includes four units for use in each of grades 4 through 6. The fourth grade units are entitled Measurement Systems, Classification Systems, Bio-Control Systems, and Hydrologic Systems; the fifth grade units are Chemical Systems, Force Systems, Bio-Systems, and Astro-Systems; and the sixth grade units are Equilibrium Systems,…
National Science Education Standards.
ERIC Educational Resources Information Center
National Academy of Sciences - National Research Council, Washington, DC.
The National Science Education Standards present a vision of a scientifically literate populace. The standards outline what students need to know, understand, and be able to do to be scientifically literate at different grade levels. They describe an educational system in which all students demonstrate high levels of performance, teachers are…
[Assessment of an Evaluation System for Psychiatry Learning].
Campo-Cabal, Gerardo
2012-01-01
Through the analysis of a teaching evaluation system for a Psychiatry course aimed at Medicine students, the author reviews the basic elements taken into account in a teaching assessment process. Analysis was carried out of the assessment methods used as well as of the grades obtained by the students from four groups into which the they were divided. The selected assessment methods are appropriate to evaluate educational objectives; the contents are selected by means of a specification matrix; there is a high correlation coefficient between the grades obtained in previous academic periods and the ones obtained in the course, thus demonstrating the validity of the results (both considering the whole exam or just a part of it). Most of the students are on the right side of the grading curve, which means that the majority of them acquire the knowledge expected. The assessment system used in the Psychopathology course is fair, valid and reliable, specifically concerning the objective methods used, but the conceptual evaluation should be improved or, preferably, eliminated as a constituernt part of the evaluation system. Copyright © 2012 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.
Zhou, Xiao Yi; Lu, Xinyan; Raparia, Kirtee; Chen, Yi-Hua
2018-06-01
Triple-hit lymphoma is a highly aggressive B-cell lymphoma. We report a case of triple-hit lymphoma transformed from systemic follicular lymphoma (FL) after 9-year remission and presented primarily as an isolated orbital mass without systemic symptoms or lymphadenopathy. A 58-year-old female presented with intermittent vertical binocular diplopia, left upper eyelid swelling and pain and was found to have a 2.9 cm orbital mass. Histological section revealed a CD10-positive large B-cell lymphoma, consistent with transformation of FL. Fluorescent in situ hybridization (FISH) analysis demonstrated rearrangements involving C-MYC, BCL-2 and BCL-6 genes, indicating a high grade, triple-hit lymphoma. Triple-hit lymphoma transformed from a low-grade lymphoma may initially present as an isolated orbital mass without systemic evidence of transformation. Early recognition of double or triple-hit lymphomas is important since these patients require aggressive chemotherapy.
Systems, Subjects, Sessions: To What Extent Do These Factors Influence EEG Data?
Melnik, Andrew; Legkov, Petr; Izdebski, Krzysztof; Kärcher, Silke M; Hairston, W David; Ferris, Daniel P; König, Peter
2017-01-01
Lab-based electroencephalography (EEG) techniques have matured over decades of research and can produce high-quality scientific data. It is often assumed that the specific choice of EEG system has limited impact on the data and does not add variance to the results. However, many low cost and mobile EEG systems are now available, and there is some doubt as to the how EEG data vary across these newer systems. We sought to determine how variance across systems compares to variance across subjects or repeated sessions. We tested four EEG systems: two standard research-grade systems, one system designed for mobile use with dry electrodes, and an affordable mobile system with a lower channel count. We recorded four subjects three times with each of the four EEG systems. This setup allowed us to assess the influence of all three factors on the variance of data. Subjects performed a battery of six short standard EEG paradigms based on event-related potentials (ERPs) and steady-state visually evoked potential (SSVEP). Results demonstrated that subjects account for 32% of the variance, systems for 9% of the variance, and repeated sessions for each subject-system combination for 1% of the variance. In most lab-based EEG research, the number of subjects per study typically ranges from 10 to 20, and error of uncertainty in estimates of the mean (like ERP) will improve by the square root of the number of subjects. As a result, the variance due to EEG system (9%) is of the same order of magnitude as variance due to subjects (32%/sqrt(16) = 8%) with a pool of 16 subjects. The two standard research-grade EEG systems had no significantly different means from each other across all paradigms. However, the two other EEG systems demonstrated different mean values from one or both of the two standard research-grade EEG systems in at least half of the paradigms. In addition to providing specific estimates of the variability across EEG systems, subjects, and repeated sessions, we also propose a benchmark to evaluate new mobile EEG systems by means of ERP responses.
Systems, Subjects, Sessions: To What Extent Do These Factors Influence EEG Data?
Melnik, Andrew; Legkov, Petr; Izdebski, Krzysztof; Kärcher, Silke M.; Hairston, W. David; Ferris, Daniel P.; König, Peter
2017-01-01
Lab-based electroencephalography (EEG) techniques have matured over decades of research and can produce high-quality scientific data. It is often assumed that the specific choice of EEG system has limited impact on the data and does not add variance to the results. However, many low cost and mobile EEG systems are now available, and there is some doubt as to the how EEG data vary across these newer systems. We sought to determine how variance across systems compares to variance across subjects or repeated sessions. We tested four EEG systems: two standard research-grade systems, one system designed for mobile use with dry electrodes, and an affordable mobile system with a lower channel count. We recorded four subjects three times with each of the four EEG systems. This setup allowed us to assess the influence of all three factors on the variance of data. Subjects performed a battery of six short standard EEG paradigms based on event-related potentials (ERPs) and steady-state visually evoked potential (SSVEP). Results demonstrated that subjects account for 32% of the variance, systems for 9% of the variance, and repeated sessions for each subject-system combination for 1% of the variance. In most lab-based EEG research, the number of subjects per study typically ranges from 10 to 20, and error of uncertainty in estimates of the mean (like ERP) will improve by the square root of the number of subjects. As a result, the variance due to EEG system (9%) is of the same order of magnitude as variance due to subjects (32%/sqrt(16) = 8%) with a pool of 16 subjects. The two standard research-grade EEG systems had no significantly different means from each other across all paradigms. However, the two other EEG systems demonstrated different mean values from one or both of the two standard research-grade EEG systems in at least half of the paradigms. In addition to providing specific estimates of the variability across EEG systems, subjects, and repeated sessions, we also propose a benchmark to evaluate new mobile EEG systems by means of ERP responses. PMID:28424600
Novel, improved grading system(s) for IDH-mutant astrocytic gliomas.
Shirahata, Mitsuaki; Ono, Takahiro; Stichel, Damian; Schrimpf, Daniel; Reuss, David E; Sahm, Felix; Koelsche, Christian; Wefers, Annika; Reinhardt, Annekathrin; Huang, Kristin; Sievers, Philipp; Shimizu, Hiroaki; Nanjo, Hiroshi; Kobayashi, Yusuke; Miyake, Yohei; Suzuki, Tomonari; Adachi, Jun-Ichi; Mishima, Kazuhiko; Sasaki, Atsushi; Nishikawa, Ryo; Bewerunge-Hudler, Melanie; Ryzhova, Marina; Absalyamova, Oksana; Golanov, Andrey; Sinn, Peter; Platten, Michael; Jungk, Christine; Winkler, Frank; Wick, Antje; Hänggi, Daniel; Unterberg, Andreas; Pfister, Stefan M; Jones, David T W; van den Bent, Martin; Hegi, Monika; French, Pim; Baumert, Brigitta G; Stupp, Roger; Gorlia, Thierry; Weller, Michael; Capper, David; Korshunov, Andrey; Herold-Mende, Christel; Wick, Wolfgang; Louis, David N; von Deimling, Andreas
2018-04-23
According to the 2016 World Health Organization Classification of Tumors of the Central Nervous System (2016 CNS WHO), IDH-mutant astrocytic gliomas comprised WHO grade II diffuse astrocytoma, IDH-mutant (AII IDHmut ), WHO grade III anaplastic astrocytoma, IDH-mutant (AAIII IDHmut ), and WHO grade IV glioblastoma, IDH-mutant (GBM IDHmut ). Notably, IDH gene status has been made the major criterion for classification while the manner of grading has remained unchanged: it is based on histological criteria that arose from studies which antedated knowledge of the importance of IDH status in diffuse astrocytic tumor prognostic assessment. Several studies have now demonstrated that the anticipated differences in survival between the newly defined AII IDHmut and AAIII IDHmut have lost their significance. In contrast, GBM IDHmut still exhibits a significantly worse outcome than its lower grade IDH-mutant counterparts. To address the problem of establishing prognostically significant grading for IDH-mutant astrocytic gliomas in the IDH era, we undertook a comprehensive study that included assessment of histological and genetic approaches to prognosis in these tumors. A discovery cohort of 211 IDH-mutant astrocytic gliomas with an extended observation was subjected to histological review, image analysis, and DNA methylation studies. Tumor group-specific methylation profiles and copy number variation (CNV) profiles were established for all gliomas. Algorithms for automated CNV analysis were developed. All tumors exhibiting 1p/19q codeletion were excluded from the series. We developed algorithms for grading, based on molecular, morphological and clinical data. Performance of these algorithms was compared with that of WHO grading. Three independent cohorts of 108, 154 and 224 IDH-mutant astrocytic gliomas were used to validate this approach. In the discovery cohort several molecular and clinical parameters were of prognostic relevance. Most relevant for overall survival (OS) was CDKN2A/B homozygous deletion. Other parameters with major influence were necrosis and the total number of CNV. Proliferation as assessed by mitotic count, which is a key parameter in 2016 CNS WHO grading, was of only minor influence. Employing the parameters most relevant for OS in our discovery set, we developed two models for grading these tumors. These models performed significantly better than WHO grading in both the discovery and the validation sets. Our novel algorithms for grading IDH-mutant astrocytic gliomas overcome the challenges caused by introduction of IDH status into the WHO classification of diffuse astrocytic tumors. We propose that these revised approaches be used for grading of these tumors and incorporated into future WHO criteria.
Direct Metal Deposition of Functional Graded Structures in Ti- Al System
NASA Astrophysics Data System (ADS)
Shishkovsky, I.; Missemer, F.; Smurov, I.
A direct laser metal deposition (DLMD) technology with co-axial powder injection is used to fabricate a complex functional graded structure (FGS) fabrication. The aim of the study is to demonstrate the possibility to produce intermetallic phases in the Ti-Al powder systems in the course of a single-step DMD process. Besides, relationships between the main laser cladding parameters and the intermetallic phase structures of the built-up objects have been studied. In our research we applied the optical microscopy, X-ray analysis, microhardness measurement and SEM with EDX analysis of the laser-fabricated intermetallics. The discussion of the mechanisms of Ti x Al y (x,y = 1.3) intermetallic transformations in exothermal reactions is also offered in the report.
Optical fiber design with orbital angular momentum light purity higher than 99.9.
Zhang, Zhishen; Gan, Jiulin; Heng, Xiaobo; Wu, Yuqing; Li, Qingyu; Qian, Qi; Chen, Dongdan; Yang, Zhongmin
2015-11-16
The purity of the synthesized orbital-angular-momentum (OAM) light in the fiber is inversely proportional to channel crosstalk level in the OAM optical fiber communication system. Here the relationship between the fiber structure and the purity is firstly demonstrated in theory. The graded-index optical fiber is proposed and designed for the OAM light propagation with the purity higher than 99.9%. 16 fiber modes (10 OAM modes) have been supported by a specific designed graded-index optical fiber with dispersion less than 35 ps/(km∙nm). Such fiber design has suppressed the intrinsic crosstalk to be lower than -30 dB, and can be potentially used for the long distance OAM optical communication system.
ERIC Educational Resources Information Center
Conway, Lorraine
This document offers an explanation and drawings of each of the major systems of the human body and of the five senses. It provides teachers with classroom activities, demonstrations, and experiments which are intended to involve students in the acquisition of knowledge concerning the structure and function of their bodies. The drawings of the…
Child Adjustment to First Grade as Perceived by the Parents: The Role of Parents' Personal Growth.
Ben Shlomo, Shirley; Taubman-Ben-Ari, Orit
2017-04-01
The current study aimed at investigating the direct and moderating role of personal growth in a child's adjustment to first grade as perceived by the parents, drawing on Positive Psychology (Seligman & Csikszentmihalyi, ) and the theory of families as systems (Cox & Paley, ). The sample consisted of 280 Israeli parents (213 mothers and 67 fathers) whose children were in first grade. The participants completed questionnaires relating to background variables of the parent and child, as well as parents' perceived stress, emotional intelligence, perceived child's adjustment to school and personal growth. The findings indicate that a child's entrance into the school system may lead to personal growth in the parents and that variables of both the parent (age and education) and the child (birth order) contribute to this process. Furthermore, among parents with a low level of personal growth, higher emotional intelligence was associated with a more positive assessment of the child's adjustment. The study thus demonstrates that the transition to first grade may serve as a lever for the parents' growth and development, which in turn may affect their perception of their child's adjustment to school. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Gazelle, Heidi; Shell, Madelynn D.
2017-01-01
Consistent with a holistic perspective emphasizing the integration of multiple individual characteristics within child systems, it was hypothesized that subgroups of anxious solitary (AS) children differentiated by agreeable, normal, attention-seeking, and externalizing behaviors would demonstrate enduring heterogeneity in peer relations over the…
Alternative beam configuration for a Canadian Ka-band satellite system
NASA Technical Reports Server (NTRS)
Hindson, Daniel J.; Caron, Mario
1995-01-01
Satellite systems operating in the Ka-band have been proposed to offer wide band personal communications services to fixed earth terminals employing small aperture antennas as well as to mobile terminals. This requirement to service a small aperture antenna leads to a satellite system utilizing small spot beams. The traditional approach is to cover the service area with uniform spot beams which have been sized to provide a given grade of service at the worst location over the service area and to place them in a honeycomb pattern. In the lower frequency bands this approach leads to a fairly uniform grade of service over the service area due to the minimal effects of rain on the signals. At Ka-band, however, the effects of rain are quite significant. Using this approach over a large service area (e.g. Canada) where the geographic distribution of rain impairment varies significantly yields an inefficient use of satellite resources to provide a uniform grade of service. An alternative approach is to cover the service area using more than one spot beam size in effect linking the spot beam size to the severity of the rain effects in a region. This paper demonstrates how for a Canadian Ka-band satellite system, that the use of two spot beam sizes can provide a more uniform grade of service across the country as well as reduce the satellite payload complexity over a design utilizing a single spot beam size.
Toptaş, Tayfun; Peştereli, Elif; Bozkurt, Selen; Erdoğan, Gülgün; Şimşek, Tayup
2018-03-01
To examine correlations among nuclear, architectural, and International Federation of Gynecology and Obstetrics (FIGO) grading systems, and their relationships with lymph node (LN) involvement in endometrioid endometrial cancer. Histopathology slides of 135 consecutive patients were reviewed with respect to tumor grade and LN metastasis. Notable nuclear atypia was defined as grade 3 nuclei. FIGO grade was established by raising the architectural grade (AG) by one grade when the tumor was composed of cells with nuclear grade (NG) 3. Correlations between the grading systems were analyzed using Spearman's rank correlation coefficients, and relationships of grading systems with LN involvement were assessed using logistic regression analysis. Correlation analysis revealed a significant and strongly positive relationship between FIGO and architectural grading systems (r=0.885, p=0.001); however, correlations of nuclear grading with the architectural (r=0.535, p=0.165) and FIGO grading systems (r=0.589, p=0.082) were moderate and statistically non-significant. Twenty-five (18.5%) patients had LN metastasis. LN involvement rates differed significantly between tumors with AG 1 and those with AG 2, and tumors with FIGO grade 1 and those with FIGO grade 2. In contrast, although the difference in LN involvement rates failed to reach statistical significance between tumors with NG 1 and those with NG 2, it was significant between NG 2 and NG 3 (p=0.042). Although all three grading systems were associated with LN involvement in univariate analyses, an independent relationship could not be established after adjustment for other confounders in multivariate analysis. Nuclear grading is significantly correlated with neither architectural nor FIGO grading systems. The differences in LN involvement rates in the nuclear grading system reach significance only in the setting of tumor cells with NG 3; however, none of the grading systems was an independent predictor of LN involvement.
Tang, Hongying Lilian; Goh, Jonathan; Peto, Tunde; Ling, Bingo Wing-Kuen; Al Turk, Lutfiah Ismail; Hu, Yin; Wang, Su; Saleh, George Michael
2013-01-01
In any diabetic retinopathy screening program, about two-thirds of patients have no retinopathy. However, on average, it takes a human expert about one and a half times longer to decide an image is normal than to recognize an abnormal case with obvious features. In this work, we present an automated system for filtering out normal cases to facilitate a more effective use of grading time. The key aim with any such tool is to achieve high sensitivity and specificity to ensure patients' safety and service efficiency. There are many challenges to overcome, given the variation of images and characteristics to identify. The system combines computed evidence obtained from various processing stages, including segmentation of candidate regions, classification and contextual analysis through Hidden Markov Models. Furthermore, evolutionary algorithms are employed to optimize the Hidden Markov Models, feature selection and heterogeneous ensemble classifiers. In order to evaluate its capability of identifying normal images across diverse populations, a population-oriented study was undertaken comparing the software's output to grading by humans. In addition, population based studies collect large numbers of images on subjects expected to have no abnormality. These studies expect timely and cost-effective grading. Altogether 9954 previously unseen images taken from various populations were tested. All test images were masked so the automated system had not been exposed to them before. This system was trained using image subregions taken from about 400 sample images. Sensitivities of 92.2% and specificities of 90.4% were achieved varying between populations and population clusters. Of all images the automated system decided to be normal, 98.2% were true normal when compared to the manual grading results. These results demonstrate scalability and strong potential of such an integrated computational intelligence system as an effective tool to assist a grading service.
Interference studies with two hospital-grade and two home-grade glucose meters.
Lyon, Martha E; Baskin, Leland B; Braakman, Sandy; Presti, Steven; Dubois, Jeffrey; Shirey, Terry
2009-10-01
Interference studies of four glucose meters (Nova Biomedical [Waltham, MA] StatStrip [hospital grade], Roche Diagnostics [Indianapolis, IN] Accu-Chek Aviva [home grade], Abbott Diabetes Care [Alameda, CA] Precision FreeStyle Freedom [home grade], and LifeScan [Milpitas, CA] SureStep Flexx [hospital grade]) were evaluated and compared to the clinical laboratory plasma hexokinase reference method (Roche Hitachi 912 chemistry analyzer). These meters were chosen to reflect the continuum of care from hospital to home grade meters commonly seen in North America. Within-run precision was determined using a freshly prepared whole blood sample spiked with concentrated glucose to give three glucose concentrations. Day-to-day precision was evaluated using aqueous control materials supplied by each vendor. Common interferences, including hematocrit, maltose, and ascorbate, were tested alone and in combination with one another on each of the four glucose testing devices at three blood glucose concentrations. Within-run precision for all glucose meters was <5% except for the FreeStyle (up to 7.6%). Between-day precision was <6% for all glucose meters. Ascorbate caused differences (percentage change from a sample without added interfering substances) of >5% with pyrroloquinolinequinone (PQQ)-glucose dehydrogenase-based technologies (Aviva and Freestyle) and the glucose oxidase-based Flexx meter. Maltose strongly affected the PQQ-glucose dehydrogenase-based meter systems. When combinations of interferences (ascorbate, maltose, and hematocrit mixtures) were tested, the extent of the interference was up to 193% (Aviva), 179% (FreeStyle), 25.1% (Flexx), and 5.9% (StatStrip). The interference was most pronounced at low glucose (3.9-4.4 mmol/L). All evaluated glucose meter systems demonstrated varying degrees of interference by hematocrit, ascorbate, and maltose mixtures. PQQ-glucose dehydrogenase-based technologies showed greater susceptibility than glucose oxidase-based systems. However, the modified glucose oxidase-based amperometric method (Nova StatStrip) was less affected in comparison with the glucose oxidase-based photometric method (LifeScan SureStep Flexx).
Brosseau, Lucie; Wells, George A; Pugh, Arlanna G; Smith, Christine Am; Rahman, Prinon; Àlvarez Gallardo, Inmaculada C; Toupin-April, Karine; Loew, Laurianne; De Angelis, Gino; Cavallo, Sabrina; Taki, Jade; Marcotte, Rachel; Fransen, Marlene; Hernandez-Molina, Gabriela; Kenny, Glen P; Regnaux, Jean-Philippe; Lefevre-Colau, Marie-Martine; Brooks, Sydney; Laferriere, Lucie; McLean, Linda; Longchamp, Guy
2016-10-01
The primary objective is to identify effective land-based therapeutic exercise interventions and provide evidence-based recommendations for managing hip osteoarthritis. A secondary objective is to develop an Ottawa Panel evidence-based clinical practice guideline for hip osteoarthritis. The search strategy and modified selection criteria from a Cochrane review were used. Studies included hip osteoarthritis patients in comparative controlled trials with therapeutic exercise interventions. An Expert Panel arrived at a Delphi survey consensus to endorse the recommendations. The Ottawa Panel hierarchical alphabetical grading system (A, B, C+, C, D, D+, or D-) considered the study design (level I: randomized controlled trial and level II: controlled clinical trial), statistical significance (p < 0.5), and clinical importance (⩾15% improvement). Four high-quality studies were included, which demonstrated that variations of strength training, stretching, and flexibility exercises are generally effective for improving the management of hip osteoarthritis. Strength training exercises displayed the greatest improvements for pain (Grade A), disability (Grades A and C+), physical function (Grade A), stiffness (Grade A), and range of motion (Grade A) within a short time period (8-24 weeks). Stretching also greatly improved physical function (Grade A), and flexibility exercises improved pain (Grade A), range of motion (Grade A), physical function (Grade A), and stiffness (Grade C+). The Ottawa Panel recommends land-based therapeutic exercise, notably strength training, for management of hip osteoarthritis in reducing pain, stiffness and self-reported disability, and improving physical function and range of motion. © The Author(s) 2015.
Waste Heat-to-Power Using Scroll Expander for Organic Rankine Bottoming Cycle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dieckmann, John; Smutzer, Chad; Sinha, Jayanti
The objective of this program was to develop a novel, scalable scroll expander for conversion of waste heat to power; this was accomplished and demonstrated in both a bench-scale system as well as a full-scale system. The expander is a key component in Organic Rankine Cycle (ORC) waste heat recovery systems which are used to convert medium-grade waste heat to electric power in a wide range of industries. These types of waste heat recovery systems allow for the capture of energy that would otherwise just be exhausted to the atmosphere. A scroll expander has the benefit over other technologies ofmore » having high efficiency over a broad range of operating conditions. The speed range of the TIAX expander (1,200 to 3,600 RPM) enables the shaft power output to directly drive an electric generator and produce 60 Hz electric power without incurring the equipment costs or losses of electronic power conversion. This greatly simplifies integration with the plant electric infrastructure. The TIAX scroll expander will reduce the size, cost, and complexity of a small-scale waste heat recovery system, while increasing the system efficiency compared to the prevailing ORC technologies at similar scale. During this project, TIAX demonstrated the scroll expander in a bench-scale test setup to have isentropic efficiency of 70-75% and operated it successfully for ~200 hours with minimal wear. This same expander was then installed in a complete ORC system driven by a medium grade waste heat source to generate 5-7 kW of electrical power. Due to funding constraints, TIAX was unable to complete this phase of testing, although the initial results were promising and demonstrated the potential of the technology.« less
Yokoyama, Shunichi; Kajiya, Yoriko; Yoshinaga, Takuma; Tani, Atsushi; Hirano, Hirofumi
2014-06-01
In the diagnosis of Alzheimer's disease (AD), discrepancies are often observed between magnetic resonance imaging (MRI) and brain perfusion single-photon emission computed tomography (SPECT) findings. MRI, brain perfusion SPECT, and amyloid positron emission tomography (PET) findings were compared in patients with mild cognitive impairment or early AD to clarify the discrepancies between imaging modalities. Several imaging markers were investigated, including the cortical average standardized uptake value ratio on amyloid PET, the Z-score of a voxel-based specific regional analysis system for AD on MRI, periventricular hyperintensity grade, deep white matter hyperintense signal grade, number of microbleeds, and three indicators of the easy Z-score imaging system for a specific SPECT volume-of-interest analysis. Based on the results of the regional analysis and the three indicators, we classified patients into four groups and then compared the results of amyloid PET, periventricular hyperintensity grade, deep white matter hyperintense signal grade, and the numbers of microbleeds among the groups. The amyloid deposition was the highest in the group that presented typical AD findings on both the regional analysis and the three indicators. The two groups that showed an imaging discrepancy between the regional analysis and the three indicators demonstrated intermediate amyloid deposition findings compared with the typical and atypical groups. The patients who showed hippocampal atrophy on the regional analysis and atypical AD findings using the three indicators were approximately 60% amyloid-negative. The mean periventricular hyperintensity grade was highest in the typical group. Patients showing discrepancies between MRI and SPECT demonstrated intermediate amyloid deposition findings compared with patients who showed typical or atypical findings. Strong white matter signal abnormalities on MRI in patients who presented typical AD findings provided further evidence for the involvement of vascular factors in AD. © 2014 The Authors. Psychogeriatrics © 2014 Japanese Psychogeriatric Society.
von Engelhardt, L V; Schmitz, A; Burian, B; Pennekamp, P H; Schild, H H; Kraft, C N; von Falkenhausen, M
2008-09-01
The literature contains only a few studies investigating the magnetic resonance imaging (MRI) diagnostics of degenerative cartilage diseases. Studies on MRI diagnostics of the cartilage using field strengths of 3-Tesla demonstrate promising results. To assess the value of 3-Tesla MRI for decision making regarding conservative or operative treatment possibilities, this study focused on patients with degenerative cartilage diseases. Thirty-two patients with chronic knee pain, a minimum age of 40 years, a negative history of trauma, and at least grade II degenerative cartilage disease were included. Cartilage abnormalities detected at preoperative 3-Tesla MRI (axial/koronar/sagittal PD-TSE-SPAIR, axial/sagittal 3D-T1-FFE, axial T2-FFE; Intera 3.0T, Philips Medical Systems) were classified (grades I-IV) and compared with arthroscopic findings. Thirty-six percent (70/192) of the examined cartilage surfaces demonstrated no agreement between MRI and arthroscopic grading. In most of these cases, grades II and III cartilage lesions were confounded with each other. Regarding the positive predictive values, the probability that a positive finding in MRI would be exactly confirmed by arthroscopy was 39-72%. In contrast, specificities and negative predictive values of different grades of cartilage diseases were 85-95%. Regarding the high specificities and negative predictive values, 3-Tesla MRI is a reliable method for excluding even slight cartilage degeneration. In summary, in degenerative cartilage diseases, 3-Tesla MRI is a supportive, noninvasive method for clinical decision making regarding conservative or operative treatment possibilities. However, the value of diagnostic arthroscopy for a definitive assessment of the articular surfaces and for therapeutic planning currently cannot be replaced by 3-Tesla MRI. This applies especially to treatment options in which a differentiation between grade II and III cartilage lesions is of interest.
[The WHO/ISUP grading system for renal carcinoma].
Moch, H
2016-07-01
Histological tumor grading is an accepted prognostic parameter of renal cell carcinoma (RCC). In 2012, the International Society of Urologic Pathologists (ISUP) proposed a novel grading system for RCC, mainly based on the evaluation of nucleoli: grade 1 tumors have nucleoli that are inconspicuous and basophilic at ×400 magnification; grade 2 tumors have nucleoli that are clearly visible at ×400 magnification and eosinophilic; grade 3 tumors have clearly visible nucleoli at ×100 magnification; and grade 4 tumors have extreme pleomorphism or rhabdoid and/or sarcomatoid morphology. This grading system was validated for clear cell renal cell carcinoma and papillary renal cell carcinoma. At the same time, the ISUP proposed not grading chromophobe renal cell carcinomas according to this system. At a consensus conference in Zurich the World Health Organization (WHO) recommended the ISUP grading system; thus, the WHO/ISUP grading system is now going to be implemented internationally. The ISUP/WHO grading system has not been validated as a prognostic parameter for other tumor subtypes, but can be used for descriptive purposes.
NEUROSARCOIDOSIS MASQUERADING AS A CENTRAL NERVOUS SYSTEM TUMOR.
Elia, Maxwell; Kombo, Ninani; Huang, John
2017-01-01
To report a case of neurosarcoidosis with an isolated brain lesion mimicking a low-grade glioma. A 38-year-old woman presented with 2 weeks of blurry vision in the left eye. Ophthalmic examination, visual field testing, fluorescein angiography, laboratory testing, and MRI of the brain were performed. Ophthalmic examination revealed left-sided optic nerve infiltration, and MRI of the brain demonstrated a solitary lesion in the brain. The visual symptoms and ophthalmic examination improved significantly with initiation of high-dose oral prednisone. Because the MRI appearance was concerning for malignancy, a brain biopsy was performed. Pathology demonstrated gliosis consistent with a low-grade central nervous system (CNS) glioma. One year later, after initial loss to ophthalmic follow-up, the right optic nerve became involved, and the patient was again treated successfully for presumed ocular sarcoidosis. At this time, serial neuroimaging demonstrated enlargement of the CNS lesion, prompting rebiopsy. Rebiopsy demonstrated a noncaseating granuloma, confirming the diagnosis of neurosarcoidosis. The patient was treated with 20 mg of methotrexate weekly and a prednisone taper with improvement in visual and neurologic symptoms. The authors present an unusual case of neurosarcoidosis masquerading as a CNS glioma. In cases of solitary CNS granulomas, radiographically differentiating neurosarcoidosis from a glioma can be challenging. In this case, serial ophthalmic examination identifying sequential involvement of both optic nerves helped to identify the underlying cause of the CNS disease as sarcoidosis.
Sagiyama, Koji; Watanabe, Yuji; Kamei, Ryotaro; Hong, Sungtak; Kawanami, Satoshi; Matsumoto, Yoshihiro; Honda, Hiroshi
2017-12-01
To investigate the usefulness of voxel-based analysis of standardized uptake values (SUVs) and apparent diffusion coefficients (ADCs) for evaluating soft-tissue tumour malignancy with a PET/MR system. Thirty-five subjects with either ten low/intermediate-grade tumours or 25 high-grade tumours were prospectively enrolled. Zoomed diffusion-weighted and fluorodeoxyglucose ( 18 FDG)-PET images were acquired along with fat-suppressed T2-weighted images (FST2WIs). Regions of interest (ROIs) were drawn on FST2WIs including the tumour in all slices. ROIs were pasted onto PET and ADC-maps to measure SUVs and ADCs within tumour ROIs. Tumour volume, SUVmax, ADCminimum, the heterogeneity and the correlation coefficients of SUV and ADC were recorded. The parameters of high- and low/intermediate-grade groups were compared, and receiver operating characteristic (ROC) analysis was also performed. The mean correlation coefficient for SUV and ADC in high-grade sarcomas was lower than that of low/intermediate-grade tumours (-0.41 ± 0.25 vs. -0.08 ± 0.34, P < 0.01). Other parameters did not differ significantly. ROC analysis demonstrated that correlation coefficient showed the best diagnostic performance for differentiating the two groups (AUC 0.79, sensitivity 96.0%, specificity 60%, accuracy 85.7%). SUV and ADC determined via PET/MR may be useful for differentiating between high-grade and low/intermediate-grade soft tissue tumours. • PET/MR allows voxel-based comparison of SUVs and ADCs in soft-tissue tumours. • A comprehensive assessment of internal heterogeneity was performed with scatter plots. • SUVmax or ADCminimum could not differentiate high-grade sarcoma from low/intermediate-grade tumours. • Only the correlation coefficient between SUV and ADC differentiated the two groups. • The correlation coefficient showed the best diagnostic performance by ROC analysis.
Three Cheers for a New Attitude.
ERIC Educational Resources Information Center
Miller, L. Diane; Labrano, Maureen B.
1992-01-01
Inservice workshop trained fourth- and fifth-grade science specialists and their students organized science demonstrations presented by students from each grade level. Describes demonstrations involving liquid bubbles, magnets, measurement, sound, aerodynamics, environmental protection, and air pollution. (MDH)
ERIC Educational Resources Information Center
Malone, Bobby G.; Nelson, Jacquelyn S.; Nelson, C. Van
The implementation of a plus/minus system of grading to replace the traditional A through F grading system for graduate students was studied at a midsize Midwestern university. Decimal equivalents were established to enable the computation of grade point averages (GPAs) that reflected the dispersion of grades through the plus/minus system. A…
Wang, Weijun; Zhen, Xin; Sun, Xu; Zhu, Zezhang; Zhu, Feng; Lam, T P; Cheng, Jack C Y; Qiu, Yong
2012-01-01
A grading system for ossification of the iliac apophysis (Risser sign) was developed for skeletal maturity assessment in the United States (US) then adopted with modifications in France (Fr) and other countries. Despite the same name, these systems have important differences. With the aim to analyzing the difference between US and Fr Risser grading systems in determining the growth maturity of girls with adolescent idiopathic scoliosis (AIS), Fifty-three AIS girls undergoing posterior spinal correction with autogenous bone graft were recruited. The Risser grades were recorded for the non-dominant side iliac crest apophysis according to the US and Fr grading systems. Growth activity was determined by standard histologic grades (HGs) on iliac crest cartilage. As a result, Kappa statistics showed poor agreement between two grading systems. The US system showed higher correlation with HGs compared to Fr system by Spearman correlation analysis. It was also found that growth cessation could be determined by Risser grade 5 of US system or Risser grade 4 of Fr system. Furthermore, by employing Receiver Operating Characteristic (ROC) curve analysis, it was found that the Risser grade 4-5 of US system with two years after menarche could be used in determining growth cessation with the highest sensitivity, specificity and accuracy. Hence it was concluded that the US Risser grading system was better in determining maturity of girls with AIS than Fr Risser grading system. By combining years since menarche, the accuracy of Risser grades in determining growth cessation could be enhanced, and the time of weaning from a brace could be advanced.
Laboratory Earth: Connecting Everything to Everything Else Online for Pre-college Educators
NASA Astrophysics Data System (ADS)
Gosselin, D.; Bonnstetter, R.; Yendra, S.; Slater, T.
2007-12-01
The Laboratory Earth professional development series, which has been funded by NASA, consists of three, three- credit hour, graduate level, distance-delivered, online courses designed for K- 8 (and above) educators. Currently, we have delivered two module-based courses, Laboratory Earth I: Earth and its Systems and Laboratory Earth II: Earth's Natural Resource Systems. A third course tentatively titled, Laboratory Earth: Earth's Changing Environments, is under development. Our objectives are to deliver a high quality professional development experience, improve participant's ability to understand and apply Earth system science concepts in their classroom, and to increase teacher's sense of belonging to a community. Each course consists of four modules that engage students using multiple strategies to meet a variety of learning styles. To document learning, content questions are used to focus the student on the concepts they will be learning throughout the course. These questions are also used to assess the progress the student has made toward learning the concepts from the beginning to the end of the course. Analysis of the responses to the content questions from Lab Earth I demonstrates significant knowledge gains from the beginning to the end of the course. Preliminary data also suggests that the extent of learning is higher in the 8-week version than it is in the 16-week version of the course. An implicit goal of the courses is to help participants focus on learning, not grades. Unfortunately, grades have to be issued. Our grading strategy has evolved to a system that uses the ability of students to master course content along with active participation and the on-time, quality completion of the grading elements in the course. Course content mastery can be demonstrated in a variety of ways and it is up to the student to choose the method that they would like to use. Methods include writing essays, creating presentations, preparing an oral journal, and developing concept maps. If tasks that a student submits are not complete, they are asked to revisit the assignment. The goal is for the student to be intrinsically motivated to learn the material and reduce the need for grades as a motivator and distract from their learning. We want everyone to work until they have the required concept knowledge and understanding. The combined results from STEBI-A (teacher efficacy for teaching science scale), LEO, (scale to assess teacher's sense of community within the course), and BES (Beliefs About Earth Science to assess the degree to which teachers enjoy teaching science) demonstrate statistically significant growth in teachers' sense of cohesion of the course and the value they place on teaching Earth science. The Laboratory Earth series is a key component of an initiative to create a collaborative online, distance delivered, masters degree program at UNL.
Shields-1, A SmallSat Radiation Shielding Technology Demonstration
NASA Technical Reports Server (NTRS)
Thomsen, D. Laurence, III; Kim, Wousik; Cutler, James W.
2015-01-01
The NASA Langley Research Center Shields CubeSat initiative is to develop a configurable platform that would allow lower cost access to Space for materials durability experiments, and to foster a pathway for both emerging and commercial-off-the-shelf (COTS) radiation shielding technologies to gain spaceflight heritage in a relevant environment. The Shields-1 will be Langleys' first CubeSat platform to carry out this mission. Radiation shielding tests on Shields-1 are planned for the expected severe radiation environment in a geotransfer orbit (GTO), where advertised commercial rideshare opportunities and CubeSat missions exist, such as Exploration Mission 1 (EM-1). To meet this objective, atomic number (Z) graded radiation shields (Zshields) have been developed. The Z-shield properties have been estimated, using the Space Environment Information System (SPENVIS) radiation shielding computational modeling, to have 30% increased shielding effectiveness of electrons, at half the thickness of a corresponding single layer of aluminum. The Shields-1 research payload will be made with the Z-graded radiation shields of varying thicknesses to create dose-depth curves to be compared with baseline materials. Additionally, Shields-1 demonstrates an engineered Z-grade radiation shielding vault protecting the systems' electronic boards. The radiation shielding materials' performances will be characterized using total ionizing dose sensors. Completion of these experiments is expected to raise the technology readiness levels (TRLs) of the tested atomic number (Z) graded materials. The most significant contribution of the Z-shields for the SmallSat community will be that it enables cost effective shielding for small satellite systems, with significant volume constraints, while increasing the operational lifetime of ionizing radiation sensitive components. These results are anticipated to increase the development of CubeSat hardware design for increased mission lifetimes, and enable out of low earth orbit (LEO) missions by using these tested material concepts as shielding for sensitive components and new spaceflight hardware
Serving Grades Over the Internet.
ERIC Educational Resources Information Center
Harris, James K.
This paper demonstrates a grade server that allows college students to access their grades over the Internet from the instructor's home page. Using a CGI (common gateway interface) program written in Visual Basic, the grades are read directly from an Excel spreadsheet and presented to the requester after he/she enters a password. The grade for…
Project HOLD: A Secondary Learning Disability Project.
ERIC Educational Resources Information Center
Snyder, Marjorie Sims
This document discusses Project HOLD, a Title VI-G Child Service Demonstration Center which was established as a cooperative effort between Northeast Louisiana University and the Ouachita Parish School System. The primary purpose of the project is to plan, explore, implement, and refine a program for students in grades 7 through 12 who have been…
Space Science in Action: Earth [Videotape].
ERIC Educational Resources Information Center
1999
This videotape recording explains the factors that allow life to flourish on Earth, including our position within the solar system, the water cycle, and the composition of the planet. A hands-on activity demonstrates the earth's water cycle. Contents include a teacher's guide designed to help science teachers in grades 5-8 by providing a brief…
ERIC Educational Resources Information Center
Wagner, Bartlett Adam
Compared were written, oral, and construction responses to science demonstrations of economically advantaged and disadvantaged sixth grade students. The study was designed to gain a greater understanding of academic performance of disadvantaged pupils in elementary school science. Five demonstrations were presented to each pupil, who then wrote…
Hergt, Franziska; von Bomhard, Wolf; Kent, Michael S; Hirschberger, Johannes
2016-09-01
Mast cell tumors (MCT) represent the most common malignant skin tumor in the dog. Diagnosis of an MCT can be achieved through cytologic examination of a fine-needle aspirate. However, the grade of the tumor is an important prognostic marker and currently requires histologic assessment. Recently a 2-tier histologic grading system based on nuclear features including number of mitoses, multinucleated cells, bizarre nuclei, and karyomegaly was proposed. The aim of this study was to assess if the cytomorphologic criteria proposed in the 2-tier histologic grading system are applicable to cytology specimens. A total of 141 MCT specimens reported as grade I, II, or III according to the Patnaik system with both histologic specimens and fine-needle aspirates available were histologically and cytologically reevaluated in a retrospective study. According to the 2-tier grading system, 38 cases were diagnosed histologically as high-grade and 103 as low-grade MCT. Cytologic grading resulted in 36 high-grade and 105 low-grade tumors. Agreement between histologic and cytologic grading based on the 2-tier grading system was achieved in 133 cases (sensitivity 86.8%, specificity 97.1%, kappa value 0.853), but 5 high-grade tumors on histology were classified as low-grade on cytology. Cytologic grading of MCT in the dog is helpful for initial assessment. However, the reliability of cytology using the 2-tier grading system is considered inadequate at this point. Prospective studies including clinical outcome should be pursued to further determine diagnostic accuracy of cytologic mast cell grading. © 2016 American Society for Veterinary Clinical Pathology.
Reliability of injury grading systems for patients with blunt splenic trauma.
Olthof, D C; van der Vlies, C H; Scheerder, M J; de Haan, R J; Beenen, L F M; Goslings, J C; van Delden, O M
2014-01-01
The most widely used grading system for blunt splenic injury is the American Association for the Surgery of Trauma (AAST) organ injury scale. In 2007 a new grading system was developed. This 'Baltimore CT grading system' is superior to the AAST classification system in predicting the need for angiography and embolization or surgery. The objective of this study was to assess inter- and intraobserver reliability between radiologists in classifying splenic injury according to both grading systems. CT scans of 83 patients with blunt splenic injury admitted between 1998 and 2008 to an academic Level 1 trauma centre were retrospectively reviewed. Inter and intrarater reliability were expressed in Cohen's or weighted Kappa values. Overall weighted interobserver Kappa coefficients for the AAST and 'Baltimore CT grading system' were respectively substantial (kappa=0.80) and almost perfect (kappa=0.85). Average weighted intraobserver Kappa's values were in the 'almost perfect' range (AAST: kappa=0.91, 'Baltimore CT grading system': kappa=0.81). The present study shows that overall the inter- and intraobserver reliability for grading splenic injury according to the AAST grading system and 'Baltimore CT grading system' are equally high. Because of the integration of vascular injury, the 'Baltimore CT grading system' supports clinical decision making. We therefore recommend use of this system in the classification of splenic injury. Copyright © 2012 Elsevier Ltd. All rights reserved.
Alternative Grading Systems. The Practitioner, Vol. III, No. 3.
ERIC Educational Resources Information Center
De Leonibus, Nancy; Thomson, Scott
After examining some of the pros and cons of traditional grading, the demands colleges make on grading practices, and the responses of people interested in grading, a number of examples of operating alternative systems are given. The alternatives include a dual (pass/withdraw grading in some courses, traditional grading in others) system, a…
Battista, Marco Johannes; Cotarelo, Cristina; Almstedt, Katrin; Heimes, Anne-Sophie; Makris, Georgios-Marios; Weyer, Veronika; Schmidt, Marcus
2016-09-01
New insights into the carcinogenesis of ovarian cancer (OC) lead to the definition of low-grade and high-grade serous OC. In this study, we validated the MD Anderson Cancer Center (MDACC) two-tier grading system and compared it with the traditional three-tier grading system as suggested by the International Federation of Gynecology and Obstetrics (FIGO). Consecutive patients with serous OC were enrolled. These two grading systems were assessed independently from each other. Kaplan-Meier estimates and Cox-regression analyses were performed to validate and compare their prognostic impact. 143 consecutive patients entered the study. According to the Kaplan-Meier estimates, the MDACC grading system (p = 0.001) predicted the progression free survival (PFS) more precisely than the FIGO system (p = 0.025). The MDACC grading system (p = 0.008) but not the FIGO system (p = 0.329) showed a statistically significant difference in terms of disease specific survival (DSS). Multivariable Cox-regression analyses revealed an independent prognostic impact of the MDACC grading system but not of the FIGO system for PFS (HR 1.570; 95 % CI 1.007-2.449; p = 0.047, and HR 0.712; 95 % CI 0.476-1.066; p = 0.099, respectively). Concerning DSS, the two-tier grading system but not the FIGO system showed a prognostic impact in a univariable Cox-regression analysis (HR 2.152; 95 % CI 1.207-3.835; p = 0.009, and HR 1.258; 95 % CI 0.801-1.975; p = 0.319, respectively). We were able to validate the MDACC grading system in serous OC. Moreover, this grading system was stronger associated with survival than the FIGO system.
Focused terahertz waves generated by a phase velocity gradient in a parallel-plate waveguide.
McKinney, Robert W; Monnai, Yasuaki; Mendis, Rajind; Mittleman, Daniel
2015-10-19
We demonstrate the focusing of a free-space THz beam emerging from a leaky parallel-plate waveguide (PPWG). Focusing is accomplished by grading the launch angle of the leaky wave using a PPWG with gradient plate separation. Inside the PPWG, the phase velocity of the guided TE1 mode exceeds the vacuum light speed, allowing the wave to leak into free space from a slit cut along the top plate. Since the leaky wave angle changes as the plate separation decreases, the beam divergence can be controlled by grading the plate separation along the propagation axis. We experimentally demonstrate focusing of the leaky wave at a selected location at frequencies of 100 GHz and 170 GHz, and compare our measurements with numerical simulations. The proposed concept can be valuable for implementing a flat and wide-aperture beam-former for THz communications systems.
Balceniuk, Mark D; Trakimas, Lauren; Aghaie, Claudia; Mix, Doran; Rasheed, Khurram; Seaman, Matthew; Ellis, Jennifer; Glocker, Roan; Doyle, Adam; Stoner, Michael C
2018-07-01
Chronic kidney disease (CKD) is a predictor of poor outcomes for patients undergoing endovascular aortic aneurysm repair (EVAR). Anatomic severity grade (ASG) represents a quantitative mechanism for assessing anatomical suitability for endovascular aortic repair. Anatomic severity grade has been correlated with repair outcomes and resource utilization. The purpose of this study was to identify a novel renal perfusion metric as a way to assist ASG with predicting EVAR outcomes. Retrospective review of a prospectively maintained database identified elective infrarenal aortic aneurysm repair cases. Anatomic grading was undertaken by independent reviewers. Using volumetric software, kidney volume, and a novel measure of kidney functional volume, the volumetric nephrogram (VN) was recorded. Systematic evaluation of the relationship of kidney volume and VN to CKD and ASG was undertaken using linear regression and receiver-operator statistical tools. A total of 386 cases with patient and anatomic data were identified and graded. Mean age was 72.9 ± 0.4 years. Renal volume <281 mL correlated with CKD (area under the curve [AUC] = .708; P ≤ .0001). Volumetric nephrogram <22.5 HU·L correlated with CKD (AUC = 0.764; P ≤ .0001). High (≥15) ASG scores correlated with both renal volume (AUC = .628; P ≤ .0001) and VN (AUC = .628; P ≤ .0001). Regression analysis demonstrated a strong, inverse relationship between ASG and VN ( R 2 = .95). These data demonstrate that VN is a strong predictor of CKD in a large database of patients undergoing elective aneurysm repair. We demonstrate an inverse relationship between renal function and ASG that has not been previously described in the literature. Additionally, we have shown that VN complements ASG as a model of overall cardiovascular health and atherosclerotic burden. Outcomes in patients with poor renal function may be related to anatomical issues in addition to well-described systemic ramifications.
Potentiation in the first visual synapse of the fly compound eye.
Uusitalo, R O; Weckström, M
2000-04-01
In the first visual synapse of the insect compound eye, both the presynaptic and postsynaptic signals are graded, nonspiking changes in membrane voltage. The synapse exhibits tonic transmitter release (even in dark) and strong adaptation to long-lasting light backgrounds, leading to changes also in the dynamics of signal transmission. We have studied these adaptational properties of the first visual synapse of the blowfly Calliphora vicina. Investigations were done in situ by intracellular recordings from the presynaptic photoreceptors, photoreceptor axon terminals, and the postsynaptic first order visual interneurons (LMCs). The dark recovery, the shifts in intensity dependence, and the underlying processes were studied by stimulating the visual system with various adapting stimuli while observing the recovery (i.e., dark adaptation). The findings show a transient potentiation in the postsynaptic responses after intense light adaptation, and the underlying mechanisms seem to be the changes in the equilibrium potential of the transmitter-gated conductance (chloride) of the postsynaptic neurons. The potentiation by itself serves as a mechanism that after light adaptation rapidly recovers the sensitivity loss of the visual system. However, this kind of mechanism, being an intrinsic property of graded potential transmission, may be quite widespread among graded synapses, and the phenomenon demonstrates that functional plasticity is also a property of graded synaptic transmission.
NASA Technical Reports Server (NTRS)
1981-01-01
The engineering design, fabrication, assembly, operation, economic analysis, and process support R and D for an Experimental Process System Development Unit (EPSDU) are reported. About 95% of purchased equipment is received and will be reshipped to the West Coast location. The Data Collection System is completed. In the area of melting/consolidation, to the system using silicon powder transfer, melting and shotting on a pseudocontinuous basis is demonstrated. It is proposed to continue the very promising fluid bed work.
Outcomes of Patellofemoral Arthroplasty Based on Radiographic Severity.
deDeugd, Casey M; Pareek, Ayoosh; Krych, Aaron J; Cummings, Nancy M; Dahm, Diane L
2017-04-01
Patellofemoral arthroplasty (PFA) is increasingly performed for symptomatic patellofemoral arthritis. The purpose of this study was to evaluate the outcomes of PFA based on preoperative radiographic severity of patellofemoral arthritis. All patients who underwent PFA for isolated patellofemoral arthritis between 2002 and 2013 and had undergone preoperative magnetic resonance imaging were identified. Radiographic severity of patellofemoral arthritis was classified according to the Iwano classification system. Groups were divided between mild (grade 0-I) and moderate to severe (grade II-IV) patellofemoral arthritis. Clinical outcomes were evaluated using the Knee Society scores (KSS), University of California at Los Angeles (UCLA) and Tegner scores. Seventy-five knees in 55 patients met inclusion criteria. Mean age was 51 years (range, 36 to 81), and mean follow-up was 3 years (range, 2 to 10). All patients had grade IV patellofemoral chondromalacia and/or significant subchondral cyst formation and edema on magnetic resonance imaging. On plain radiographs, there were no patients with Iwano grade 0, 21 grade I, 15 grade II, 21 grade III, and 18 grade IV patellofemoral arthritis. There was significantly more improvement in KSS pain (P = .046), KSS function (P = .02), University of California at Los Angeles (UCLA) (P = .046) and Tegner (P = .008) scores in the Iwano grade II-IV group vs the Iwano grade I group. Patient-reported pain quality improved significantly more following PFA in the grade II-IV group (P = .04). Patients with evidence of mild patellofemoral arthritis on plain radiographs demonstrated less improvement in pain and function after PFA than those with more advanced patellofemoral arthritis. Caution should be used when considering PFA for patients with minimal radiographic evidence of patellofemoral arthritis. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Silberman, Donn
2006-08-01
Much work has been done in efforts to reach students in the K-12 grades to encourage them to learn about optics and related sciences and technologies. One goal of these efforts is to develop the future optical scientists and engineers to carry on the work of this and related societies. One main obstacle is to create low costs novel and effective hands-on optical components and systems for these students to use and from which to get excited. Students at different grade levels and abilities are receptive to different kinds of components and systems and this must be taken into account when preparing for outreach programs. There are, however, some guiding principles which can be used throughout the various levels, including making sure the components and systems are good examples and not marginal. Small telescopes or microscopes that use poor quality optics which provide poor quality images do more to discourage young students from going into the sciences than if they never had the experience at all. Some examples of both poor and good quality optical components and systems that will be described and demonstrated include: lenses, telescopes, microscopes, diffraction gratings, Kaleidoscopes, Fresnel Lenses, polarization filters and liquid crystals. The figures in this paper are in color and best viewed on-line or printed with a good color printer.
Rebellato, Lorita M; Arnold, Angelo N; Bozik, Karen M; Haisch, Carl E
2002-12-15
A recent proposal supports the elimination of allocation points for human leukocyte antigen (HLA) mismatches (MM) in cadaveric kidney transplantation. The intent is to increase access for some racial groups that might be disadvantaged by the representation of race-specific HLA in a largely white donor pool. We report our experience from two transplant centers that serve a large African American (AA) patient population. All cadaveric transplants into AA recipients from 1994 to 2000 (n=162) were included in a retrospective review. Superior graft survival was observed in AA recipients of 0 MM transplants. When induction therapy was used, the graft survival at 3 years for the human leukocyte antigen (HLA)-BDR MM grades given allocation points (0,1,2 MM) was 82% versus only 49% for BDR MM grades not given points (3,4 MM: =0.0022). Our collective experience demonstrates that AA patients having HLA-BDR MM grades given allocation points had better graft survival. Removing points for HLA from the national allocation system may result in significantly poorer outcome in AA kidney recipients.
A Machine Vision System for Automatically Grading Hardwood Lumber - (Proceedings)
Richard W. Conners; Tai-Hoon Cho; Chong T. Ng; Thomas H. Drayer; Joe G. Tront; Philip A. Araman; Robert L. Brisbon
1990-01-01
Any automatic system for grading hardwood lumber can conceptually be divided into two components. One of these is a machine vision system for locating and identifying grading defects. The other is an automatic grading program that accepts as input the output of the machine vision system and, based on these data, determines the grade of a board. The progress that has...
Lu, Mang; Gu, Li-Peng; Xu, Wen-Hao
2013-01-01
In this study, a novel suspended ceramsite was prepared, which has high strength, optimum density (close to water), and high porosity. The ceramsite was used to feed a moving-bed biofilm reactor (MBBR) system with an anaerobic-aerobic (A/O) arrangement to treat petroleum refinery wastewater for simultaneous removal of chemical oxygen demand (COD) and ammonium. The hydraulic retention time (HRT) of the anaerobic-aerobic MBBR system was varied from 72 to 18 h. The anaerobic-aerobic system had a strong tolerance to shock loading. Compared with the professional emission standard of China, the effluent concentrations of COD and NH3-N in the system could satisfy grade I at HRTs of 72 and 36 h, and grade II at HRT of 18 h. The average sludge yield of the anaerobic reactor was estimated to be 0.0575 g suspended solid/g CODremoved. This work demonstrated that the anaerobic-aerobic MBBR system using the suspended ceramsite as bio-carrier could be applied to achieving high wastewater treatment efficiency.
Ability-Based Criteria and the Lower Class Student: The De Facto Screw.
ERIC Educational Resources Information Center
Amato, Josephine; Backman, Carl B.
Social class discrimination in the schooling process is less a product of teachers' attitudes than of the systems by which schools group students. Although class bias has been demonstrated in grading practices and other key decision points, numerous studies have shown that teachers are less to blame for inequitable learning situations than…
Repairing Discordant Student--Teacher Relationships: A Case Study Using Emotion-Focused Therapy
ERIC Educational Resources Information Center
Lander, Itzhak
2009-01-01
This article describes the use of emotion-focused therapy (EFT) to reduce conflict in the student-teacher relationship. A case study of a homeroom teacher and a sixth-grade student is presented. This innovative family treatment model is demonstrated to be a useful tool for improving the student-teacher relational system, resulting in amelioration…
IMPROVED SPECTROPHOTOMETER FIBER SAMPLING SYSTEM FOR COTTON FIBER COLOR MEASUREMENTS
USDA-ARS?s Scientific Manuscript database
Cotton in the U.S. is classified for color using the Uster® High Volume Instrument (HVI), and the parameters Rd and +b are used to designate color grades for cotton fiber. However, Rd and +b are cotton-specific color parameters, and the need existed to demonstrate the relationships of Rd and +b to...
Experiments Demonstrate Geothermal Heating Process
ERIC Educational Resources Information Center
Roman, Harry T.
2012-01-01
When engineers design heat-pump-based geothermal heating systems for homes and other buildings, they can use coil loops buried around the perimeter of the structure to gather low-grade heat from the earth. As an alternative approach, they can drill well casings and store the summer's heat deep in the earth, then bring it back in the winter to warm…
Progression of choroid plexus papilloma.
Dhillon, Rana S; Wang, Yi Yuen; McKelvie, Penny A; O'Brien, Brendan
2013-12-01
Choroid plexus papillomas are rare neoplasms that arise from choroid plexus epithelium. The World Health Organization classification describes three histological grades. Grade I is choroid plexus papilloma, grade II is atypical choroid plexus papilloma and grade III is choroid plexus carcinoma. Progression between grades is rare but documented. We present two adult cases, a 53-year-old female and a 70-year-old male, who demonstrated clear interval histological progression from grade I choroid plexus papilloma to higher grades. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ishihara, Takayuki; Awata, Masaki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Uematsu, Masaaki; Mano, Toshiaki
2018-01-15
The ultrathin strut biodegradable polymer sirolimus-eluting stent (Orsiro, O-SES) exhibits satisfactory clinical outcomes. However, no report to date has documented the intravascular status of artery repair after O-SES implantation. We examined 5 O-SES placed in 4 patients (age 65 ± 12 years, male 75%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed immediately after percutaneous coronary intervention and 1 year later. Angioscopic images were analyzed to determine the following: (1) dominant grade of neointimal coverage (NIC) over the stent; (2) maximum yellow plaque grade; and (3) existence of thrombus. Yellow plaque grade was evaluated both immediately after stent implantation and at the time of follow-up observation. The other parameters were evaluated at the time of follow-up examination. NIC was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. Yellow plaque severity was graded as: grade 0, white; grade 1, light yellow; grade 2, yellow; and grade 3, intensive yellow. Angioscopic findings at 1 year demonstrated the following: dominant NIC grade 1, grade 2, and grade 3 in 1, 2, and 2 stents, respectively; all stents were covered to some extent; focal thrombus adhesion was observed in only 1 stent. Yellow plaque grade did not change from immediately after stent implantation to follow-up. O-SES demonstrated satisfactory arterial repair 1 year after implantation.
A Machine Vision System for Automatically Grading Hardwood Lumber - (Industrial Metrology)
Richard W. Conners; Tai-Hoon Cho; Chong T. Ng; Thomas T. Drayer; Philip A. Araman; Robert L. Brisbon
1992-01-01
Any automatic system for grading hardwood lumber can conceptually be divided into two components. One of these is a machine vision system for locating and identifying grading defects. The other is an automatic grading program that accepts as input the output of the machine vision system and, based on these data, determines the grade of a board. The progress that has...
Laser Velocimeter for Studies of Microgravity Combustion Flowfields
NASA Technical Reports Server (NTRS)
Varghese, Philip L.
2003-01-01
A velocimeter was developed based on modulated filtered Rayleigh scattering (MFRS). The MFRS velocimeter was successfully demonstrated by making one-component velocity measurements in a supersonic expansion using molecular Rayleigh scattering in a jet of N2. These measurements were made in a sweep mode where the Rayleigh scattered profile is cross-correlated with absorption in a static cell to determine velocity. To improve temporal resolution the frequency-locked mode of operation was developed, with an in-situ referencing scheme to compensate for signal fluctuations arising from density variations in the probe volume. Spectroscopic grade (i.e. continuously tunable, single-mode) laser sources with high power (greater than 100 mW) are not commercially available at the wavelength of interest (780 nm). We developed an all-solid-state system with a low power (approximately 10 mW) spectroscopic grade laser source in a Littrow cavity is amplified by a broad-area diode laser. We have demonstrated that the slaved output tracks the injected input but have not yet demonstrated power gain by the end of the grant period.
MRI differentiation of low-grade from high-grade appendicular chondrosarcoma.
Douis, Hassan; Singh, Leanne; Saifuddin, Asif
2014-01-01
To identify magnetic resonance imaging (MRI) features which differentiate low-grade chondral lesions (atypical cartilaginous tumours/grade 1 chondrosarcoma) from high-grade chondrosarcomas (grade 2, grade 3 and dedifferentiated chondrosarcoma) of the major long bones. We identified all patients treated for central atypical cartilaginous tumours and central chondrosarcoma of major long bones (humerus, femur, tibia) over a 13-year period. The MRI studies were assessed for the following features: bone marrow oedema, soft tissue oedema, bone expansion, cortical thickening, cortical destruction, active periostitis, soft tissue mass and tumour length. The MRI-features were compared with the histopathological tumour grading using univariate, multivariate logistic regression and receiver operating characteristic curve (ROC) analyses. One hundred and seventy-nine tumours were included in this retrospective study. There were 28 atypical cartilaginous tumours, 79 grade 1 chondrosarcomas, 36 grade 2 chondrosarcomas, 13 grade 3 chondrosarcomas and 23 dedifferentiated chondrosarcomas. Multivariate analysis demonstrated that bone expansion (P = 0.001), active periostitis (P = 0.001), soft tissue mass (P < 0.001) and tumour length (P < 0.001) were statistically significant differentiating factors between low-grade and high-grade chondral lesions with an area under the ROC curve of 0.956. On MRI, bone expansion, active periostitis, soft tissue mass and tumour length can reliably differentiate high-grade chondrosarcomas from low-grade chondral lesions of the major long bones. • Accurate differentiation of low-grade from high-grade chondrosarcomas is essential before surgery • MRI can reliably differentiate high-grade from low-grade chondrosarcomas of long bone • Differentiating features are bone expansion, periostitis, soft tissue mass and tumour length • Presence of these four MRI features demonstrated a diagnostic accuracy (AUC) of 95.6 % • The findings may result in more accurate diagnosis before definitive surgery.
Helpap, B; Bubendorf, L; Kristiansen, G
2016-02-01
The continued development of methods in needle biopsies and radical prostatectomy for treatment of prostate cancer has given special emphasis to the question of the prognostic relevance of the various systems of grading. The classical purely histological grading system of Gleason has been modified several times in the past decades and cleared the way for a new grading system by the prognostic grading of Epstein. Assessment of the old and also modified combined histological and cytological grading of Mostofi, the World health Organization (WHO) and the urologic-pathological working group of prostate cancer in connection with the Gleason grading (combined Gleason-Helpap grading), has led to considerably improved rates of concordance between biopsy and radical prostatectomy and to improved estimations of prognosis beside its contribution to the development of a more practicable grading system for clinical use.
Neuroradiology and histopathology in two cases of adult medulloblastoma.
Romero-Rojas, Alfredo E; Diaz-Perez, Julio A; Raju, Sharat; Lozano-Castillo, Alfonso
2014-04-01
Medulloblastoma (MB) is the most common central nervous system neoplasm in children and only rarely presents in the adult population. Recent molecular biology findings have characterized MB as a heterogeneous neoplasm distinguished by well-defined tumour subsets each with specific histologic and molecular features. Available immunohistochemical stains can now be used to differentiate the distinct molecular types of MB. This report analyzed the histopathologic and neuroradiologic features of two new cases of adult MB. Imaging studies in these patients revealed the morphological appearance of high-grade, well-circumscribed heterogeneous tumours with necrosis, located laterally within the posterior cranial fossa. Histopathology of resected samples demonstrated high-grade tumours (WHO grade IV) containing sheets of undifferentiated neural cells with high mitotic activity and evidence of necrosis. The histopathologic and molecular characteristics of these cases of MB are reviewed for potential applications in new molecular methods of imaging.
Olfactory neuroblastoma in dogs and cats--a histological and immunohistochemical analysis.
Brosinski, K; Janik, D; Polkinghorne, A; Von Bomhard, W; Schmahl, W
2012-01-01
Olfactory neuroblastoma (ONB) was identified in 13 dogs and nine cats. The tumours were subjected to microscopical examination and were graded using a human pathological grading system. In the canine and feline tumours there was more necrosis and higher mitotic activity (mitotic index and Ki67 labelling index) than reported in human ONB. Rosettes were a common feature of feline ONBs. A significant correlation was observed between the histological grade and the Ki67 labelling index. The histopathological diagnosis of ONB was confirmed immunohistochemically by demonstration of the neuronal marker neuron-specific enolase (NSE). Two other neuron-specific antibodies specific for microtubule-associated protein-2 (MAP-2) and neuronal nuclei antigen (NeuN) were evaluated. MAP-2 expression proved to have higher specificity than labelling for NSE. NeuN expression was less sensitive and of limited practical value. Copyright © 2011 Elsevier Ltd. All rights reserved.
The prognostic value of reactive stroma on prostate needle biopsy: a population-based study.
Saeter, Thorstein; Vlatkovic, Ljiljana; Waaler, Gudmund; Servoll, Einar; Nesland, Jahn M; Axcrona, Karol; Axcrona, Ulrika
2015-05-01
Reactive tumor stroma has been shown to play an active role in prostatic carcinogenesis. A grading system for reactive stroma in prostate cancer (PC) has recently been established and found to predict biochemical recurrence and prostate cancer-specific mortality (PCSM) in prostatectomized patients. To the best of our knowledge, there has been no study investigating the prognostic value of reactive stromal grading (RSG) with regard to PCSM when evaluated in diagnostic prostate needle biopsies. A population-based study on 318 patients, encompassing all cases of PC diagnosed by needle biopsies and without evidence of systemic metastasis at the time of diagnosis in Aust-Agder County in the period 1991-1999. Patients were identified by cross-referencing the Cancer Registry of Norway. Clinical data were obtained by review of medical charts. The endpoint was PCSM. RSG was evaluated on haematoxylin and eosin stained sections according to previously described criteria; grade 0, 0-5% reactive stroma; grade 1, 6-15%; grade 2, 16-50%; grade 3, 51-100%. RSG could be evaluated in 278 patients. The median follow- up time was 110 months (interquartile range: 51-171). The 10-year PC - specific survival rate for RSGs of 0, 1, 2, and 3 was 96%, 81%, 69%, and 63%, respectively (P < 0.005). RSG remained independently associated with PCSM in a multivariate Cox regression analysis adjusting for prostate-specific antigen level, clinical stage, Gleason score, and mode of treatment. The concordance index of the multivariate model was 0.814 CONCLUSIONS: Our study demonstrates that RSG in diagnostic prostate needle biopsies predicts PCSM independently of other evaluable prognostic factors. Hence, RSG could be used in addition to traditional prognostic factors for prognostication and treatment stratification of PC patients. © 2015 Wiley Periodicals, Inc.
Hansen, I; Hörmann, K; Stuck, B A; Schneider-Gêne, S; Mösges, R; Klimek, L
2003-08-01
Specific immunotherapy (SIT) represents the only specific treatment that can be offered to allergic patients apart from allergen avoidance. SIT has been widely used in pollen allergic rhinitis. Clinical efficacy has been demonstrated in several controlled clinical trials and depends on the specific allergen the individual patient is sensitive to, the quality and total amount of allergen applied, and the SIT schedule. In classic SIT, gradually increasing dosages of the allergen extract are injected subcutaneously. Several dosage schedules for subcutaneous SIT can be applied. In Cluster-SIT, 2 - 3 injections per day of treatment are given once a week during induction treatment. In this study, we investigated 64 patients (33 female, 31 male) from 18 to 54 years (26.9 +/- 5.1 years) in terms of side-effects of Cluster-SIT during induction treatment. The total amount of enlarged local reactions (> grade 1) was n = 77 or 15.2 % of all injections. Of these, 68 (88 %) were classified as immediate reactions, 8 (11 %) were late phase reactions and 1 (1 %) was immediate as well as late phase reaction. Of all enlarged local reactions, 48 (62 %) were grade 1 reactions, 13 (17 %) were grade 2 reactions, 13 (17 %) were grade 3 reactions and 1 (1 %) was a grade 4 reaction. The total amount of systemic reactions was n = 22 or 4.3 % of all injections. Of these, 19 (86 %) were classified as immediate reactions, 3 (14 %) were delayed reactions. Of all systemic reactions, 18 (82 %) were grade 1 reactions and 4 (18 %) grade 2 reactions. Grade 3 or grade 4 reactions did not occur. There were no differences in gender or age regarding the occurrence of side effects (all p > 0.05). Frequency and severity of adverse side effects in Cluster-SIT correspond to those in other dosage schedules. On behalf of security aspects, Cluster-SIT could become an interesting alternative dosage schedule for dose increase during SIT. Furthermore, in Cluster-SIT with allergoids, induction treatment can be carried out in two treatment days of approximately 2.5 hours each.
Quantitative evaluation of lumbar intervertebral disc degeneration by axial T2* mapping.
Huang, Leitao; Liu, Yuan; Ding, Yi; Wu, Xia; Zhang, Ning; Lai, Qi; Zeng, Xianjun; Wan, Zongmiao; Dai, Min; Zhang, Bin
2017-12-01
To quantitatively evaluate the clinical value and demonstrate the potential benefits of biochemical axial T2* mapping-based grading of early stages of degenerative disc disease (DDD) using 3.0-T magnetic resonance imaging (MRI) in a clinical setting.Fifty patients with low back pain and 20 healthy volunteers (control) underwent standard MRI protocols including axial T2* mapping. All the intervertebral discs (IVDs) were classified morphologically. Lumbar IVDs were graded using Pfirrmann score (I to IV). The T2* values of the anterior annulus fibrosus (AF), posterior AF, and nucleus pulposus (NP) of each lumbar IVD were measured. The differences between groups were analyzed regarding specific T2* pattern at different regions of interest.The T2* values of the NP and posterior AF in the patient group were significantly lower than those in the control group (P < .01). The T2* value of the anterior AF was not significantly different between the patients and the controls (P > .05). The mean T2*values of the lumbar IVD in the patient group were significantly lower, especially the posterior AF, followed by the NP, and finally, the anterior AF. In the anterior AF, comparison of grade I with grade III and grade I with grade IV showed statistically significant differences (P = .07 and P = .08, respectively). Similarly, in the NP, comparison of grade I with grade III, grade I with grade IV, grade II with grade III, and grade II with grade IV showed statistically significant differences (P < .001). In the posterior AF, comparison of grade II with grade IV showed a statistically significant difference (P = .032). T2 values decreased linearly with increasing degeneration based on the Pfirrmann scoring system (ρ < -0.5, P < .001).Changes in the T2* value can signify early degenerative IVD diseases. Hence, T2* mapping can be used as a diagnostic tool for quantitative assessment of IVD degeneration. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Quantitative evaluation of lumbar intervertebral disc degeneration by axial T2∗ mapping
Huang, Leitao; Liu, Yuan; Ding, Yi; Wu, Xia; Zhang, Ning; Lai, Qi; Zeng, Xianjun; Wan, Zongmiao; Dai, Min; Zhang, Bin
2017-01-01
Abstract To quantitatively evaluate the clinical value and demonstrate the potential benefits of biochemical axial T2∗ mapping-based grading of early stages of degenerative disc disease (DDD) using 3.0-T magnetic resonance imaging (MRI) in a clinical setting. Fifty patients with low back pain and 20 healthy volunteers (control) underwent standard MRI protocols including axial T2∗ mapping. All the intervertebral discs (IVDs) were classified morphologically. Lumbar IVDs were graded using Pfirrmann score (I to IV). The T2∗ values of the anterior annulus fibrosus (AF), posterior AF, and nucleus pulposus (NP) of each lumbar IVD were measured. The differences between groups were analyzed regarding specific T2∗ pattern at different regions of interest. The T2∗ values of the NP and posterior AF in the patient group were significantly lower than those in the control group (P < .01). The T2∗ value of the anterior AF was not significantly different between the patients and the controls (P > .05). The mean T2∗values of the lumbar IVD in the patient group were significantly lower, especially the posterior AF, followed by the NP, and finally, the anterior AF. In the anterior AF, comparison of grade I with grade III and grade I with grade IV showed statistically significant differences (P = .07 and P = .08, respectively). Similarly, in the NP, comparison of grade I with grade III, grade I with grade IV, grade II with grade III, and grade II with grade IV showed statistically significant differences (P < .001). In the posterior AF, comparison of grade II with grade IV showed a statistically significant difference (P = .032). T2∗ values decreased linearly with increasing degeneration based on the Pfirrmann scoring system (ρ < −0.5, P < .001). Changes in the T2∗ value can signify early degenerative IVD diseases. Hence, T2∗ mapping can be used as a diagnostic tool for quantitative assessment of IVD degeneration. PMID:29390547
Aviation Science Activities for Elementary Grades. Revised.
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC.
This guide contains the procedures and lists of materials needed for 105 aviation activities, demonstrations, and experiments. These activities, demonstrations, and experiments (suitable for students in all elementary grades) are organized into three sections by major topic area: (1) properties of air; (2) factors related to airplane flight; and…
Space Science for Children: All about the Planets [Videotape].
ERIC Educational Resources Information Center
1999
This 23-minute videotape takes children, grades K-4, on a tour of the nine planets of our solar system and explains vital statistics and interesting facts about each. Key terms such as rotation, revolution, and orbit, are explained. A hands-on activity that can be used to demonstrate how Saturn's moons actually create its beautiful rings is also…
Wake County Public School System K-5 Assessment Results: 2009-10. Measuring Up. E&R Report No. 10.19
ERIC Educational Resources Information Center
Rhea, Anisa
2010-01-01
Moderate to high percentages of Wake County Public School (WCPSS) students demonstrated grade-level performance on K-5 assessments in 2009-10. Results indicate very slight changes from prior years. The percentage of students proficient in reading book level and mathematics strands increased very slightly since 2007-08. Modest declines in…
Course Syllabus for Grades 10-12, Art. Art 2 + 3.
ERIC Educational Resources Information Center
Murray State Univ., KY.
This course syllabus is one of over 80 developed and written by the Henry County School System (Tennessee) as part of a Teacher Corps demonstration project. These syllabi provide specific descriptions of what is to be learned and at what level the student is expected to perform. The art course described here is available for students who have…
Comprehensive K-3 Reading Policy: Fundamental Principles. ExcelinEd Policy Toolkit, 2017
ERIC Educational Resources Information Center
Foundation for Excellence in Education, 2017
2017-01-01
A Comprehensive K-3 Reading Policy establishes intensive reading intervention for K-3 students to ensure they read on grade level by the end of third grade. The policy then requires third grade students to demonstrate sufficient reading skills for promotion to fourth grade. Retention provides struggling readers the additional time and intensive…
Eisinaite, Viktorija; Juraite, Dovile; Schroën, Karin; Leskauskaite, Daiva
2016-09-01
In this study we demonstrate that food-grade double emulsions can be successfully prepared using a hybrid premix emulsification system. A coarse emulsion containing beetroot juice as inner water phase, sunflower oil as oil phase and 0.5% or 1.0% whey protein isolate solution as outer water phase was prepared using a rotor stator system. This emulsion was further refined, using a bed of glass beads (diameter 71μm), through which the emulsion was pushed at different applied pressure (200-500kPa) and number of passes (1-5). All applied pressures lead to much smaller droplets while the juice remained encapsulated (>98%). The viscosity of the emulsions increased due to swelling of the internal water phase, and this implies that it is possible to encapsulate the components efficiently at relatively low internal water phase fraction at which the emulsions can be handled easily, while allowing them to obtain their final viscosity later. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noble, Russell; Dombrowski, K.; Bernau, M.
Coal-based power generation systems provide reliable, low-cost power to the domestic energy sector. These systems consume large amounts of fuel and water to produce electricity and are the target of pending regulations that may require reductions in water use and improvements in thermal efficiency. While efficiency of coal-based generation has improved over time, coal power plants often do not utilize the low-grade heat contained in the flue gas and require large volumes of water for the steam cycle make-up, environmental controls, and for process cooling and heating. Low-grade heat recovery is particularly challenging for coal-fired applications, due in large partmore » to the condensation of acid as the flue gas cools and the resulting potential corrosion of the heat recovery materials. Such systems have also not been of significant interest as recent investments on coal power plants have primarily been for environmental controls due to more stringent regulations. Also, in many regions, fuel cost is still a pass-through to the consumer, reducing the motivation for efficiency improvements. Therefore, a commercial system combining low-grade heat-recovery technologies and associated end uses to cost effectively improve efficiency and/or reduce water consumption has not yet been widely applied. However, pressures from potential new regulations and from water shortages may drive new interest, particularly in the U.S. In an effort to address this issue, the U.S. Department of Energy (DOE) has sought to identify and promote technologies to achieve this goal.« less
A particle swarm-based algorithm for optimization of multi-layered and graded dental ceramics.
Askari, Ehsan; Flores, Paulo; Silva, Filipe
2018-01-01
The thermal residual stresses (TRSs) generated owing to the cooling down from the processing temperature in layered ceramic systems can lead to crack formation as well as influence the bending stress distribution and the strength of the structure. The purpose of this study is to minimize the thermal residual and bending stresses in dental ceramics to enhance their strength as well as to prevent the structure failure. Analytical parametric models are developed to evaluate thermal residual stresses in zirconia-porcelain multi-layered and graded discs and to simulate the piston-on-ring test. To identify optimal designs of zirconia-based dental restorations, a particle swarm optimizer is also developed. The thickness of each interlayer and compositional distribution are referred to as design variables. The effect of layers number constituting the interlayer between two based materials on the performance of graded prosthetic systems is also investigated. The developed methodology is validated against results available in literature and a finite element model constructed in the present study. Three different cases are considered to determine the optimal design of graded prosthesis based on minimizing (a) TRSs; (b) bending stresses; and (c) both TRS and bending stresses. It is demonstrated that each layer thickness and composition profile have important contributions into the resulting stress field and magnitude. Copyright © 2017 Elsevier Ltd. All rights reserved.
Relationship between red wine grades and phenolics. 1. Tannin and total phenolics concentrations.
Mercurio, Meagan D; Dambergs, Robert G; Cozzolino, Daniel; Herderich, Markus J; Smith, Paul A
2010-12-08
Measuring chemical composition is a common approach to support decisions about allocating foods and beverages to grades related to market value. Red wine is a particularly complex beverage, and multiple compositional attributes are needed to account for its sensory properties, including measurement of key phenolic components such as anthocyanins, total phenolics, and tannin, which are related to color and astringency. Color has been shown to relate positively to red wine grade; however, little research has been presented that explores the relationship between astringency-related components such as total phenolic or tannin concentration and wine grade. The aim of this research has been to investigate the relationship between the wine grade allocations of commercial wineries and total phenolic and tannin concentrations, respectively, in Australian Shiraz and Cabernet Sauvignon wines. Total phenolic and tannin concentrations were determined using the methyl cellulose precipitable (MCP) tannin assay and then compared to wine grade allocations made by winemaker panels during the companies' postvintage allocation process. Data were collected from wines produced by one Australian wine company over the 2005, 2006, and 2007 vintages and by a further two companies in 2007 (total wines = 1643). Statistical analysis revealed a positive trend toward higher wine grade allocation and wines that had higher concentrations of both total phenolics and tannin, respectively. This research demonstrates that for these companies, in general, Cabernet Sauvignon and Shiraz wines allocated to higher market value grades have higher total phenolics and higher tannin concentrations and suggests that these compositional parameters should be considered in the development of future multiparameter decision support systems for relevant commercial red wine grading processes. In addition, both tannin and total phenolics would ideally be included because although, in general, a positive relationship exists between the two parameters, this relationship does not hold for all wine styles.
Swedish PE Teachers Struggle with Assessment in a Criterion-Referenced Grading System
ERIC Educational Resources Information Center
Svennberg, Lena; Meckbach, Jane; Redelius, Karin
2018-01-01
In the field of education, the international trend is to turn to criterion-referenced grading in the hope of achieving accountable and consistent grades. Despite a national criterion-referenced grading system emphasising knowledge as the only base for grading, Swedish physical education (PE) grades have been shown to value non-knowledge factors,…
Grading of direct laryngoscopy. A survey of current practice.
Cohen, A M; Fleming, B G; Wace, J R
1994-06-01
One hundred and twenty anaesthetists (30 of each grade), from three separate regions, were interviewed as to how they recorded the appearance of laryngeal structures at direct laryngoscopy and about their knowledge of the commonly used numerical grading system. About two-thirds of anaesthetists surveyed (69.2%) used the numerical grading system, but of these, over half could not identify a 'grade 2' laryngoscopic appearance correctly. Of anaesthetists who did not use the numerical method, over half could not correctly state the difference between a 'grade 2' and a 'grade 3' laryngoscopic appearance. Over 40% of anaesthetists stated incorrectly that the grading should be made on the initial view, even when laryngeal pressure had been needed. Junior anaesthetists were more likely to use the numerical method of recording. The results show that there is unacceptable uncertainty and inaccuracy in the use of the numerical grading system by users as well as non-users, which makes the current routine clinical use of the numerical grading system unsatisfactory.
Semisolid forming of S48C steel grade
NASA Astrophysics Data System (ADS)
Plata, Gorka; Lozares, Jokin; Azpilgain, Zigor; Hurtado, Iñaki; Loizaga, Iñigo; Idoyaga, Zuriñe
2017-10-01
Steel production and component manufacturing industries have to face the challenge of globalization, trying to overcome the economic pressure to remain competitive. Moreover, the lightweighting trend of the latter years implies an even higher challenge to maintain the steel use. Therefore, advanced manufacturing processes will be the cornerstone. In this field, Semisolid forming (SSF) has demonstrated the capability of obtaining complex geometries and saving raw material and energy. Despite it is complicated the SSF of sound components, in Mondragon Unibertsitatea it has been successfully demonstrated the capability of producing strong enough automotive components with 42CrMo4 steel grade. In this work, we demonstrate the capability of SSF S48C steel grade with great mechanical properties.
Dwyer, Tim; Martin, C Ryan; Kendra, Rita; Sermer, Corey; Chahal, Jaskarndip; Ogilvie-Harris, Darrell; Whelan, Daniel; Murnaghan, Lucas; Nauth, Aaron; Theodoropoulos, John
2017-06-01
To determine the interobserver reliability of the International Cartilage Repair Society (ICRS) grading system of chondral lesions in cadavers, to determine the intraobserver reliability of the ICRS grading system comparing arthroscopy and video assessment, and to compare the arthroscopic ICRS grading system with histological grading of lesion depth. Eighteen lesions in 5 cadaveric knee specimens were arthroscopically graded by 7 fellowship-trained arthroscopic surgeons using the ICRS classification system. The arthroscopic video of each lesion was sent to the surgeons 6 weeks later for repeat grading and determination of intraobserver reliability. Lesions were biopsied, and the depth of the cartilage lesion was assessed. Reliability was calculated using intraclass correlations. The interobserver reliability was 0.67 (95% confidence interval, 0.5-0.89) for the arthroscopic grading, and the intraobserver reliability with the video grading was 0.8 (95% confidence interval, 0.67-0.9). A high correlation was seen between the arthroscopic grading of depth and the histological grading of depth (0.91); on average, surgeons graded lesions using arthroscopy a mean of 0.37 (range, 0-0.86) deeper than the histological grade. The arthroscopic ICRS classification system has good interobserver and intraobserver reliability. A high correlation with histological assessment of depth provides evidence of validity for this classification system. As cartilage lesions are treated on the basis of the arthroscopic ICRS classification, it is important to ascertain the reliability and validity of this method. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Evaluating the impacts of grades on vehicular speeds on interstate highways.
Chen, Xinqiang; Li, Zhibin; Wang, Yinhai; Cui, Zhiyong; Shi, Chaojian; Wu, Huafeng
2017-01-01
Grade variation on interstate highways affects the roadway geometric design, vehicle performance and driver behavior, thus possibly exerting an unexpected effect on vehicular speed. Hence, determining the internal relationship between grade and speed is important and useful for drivers, traffic regulators and other traffic participants. However, the problem with performing this research is the lack of large-scale gradient and speed data. Google Earth (GE) provides an application programming interface for extracting elevation data worldwide. The elevation dataset from GE can be easily converted to grade data. In addition, our team has collected and stored speed series data for different freeways over several years. Based on the above obtainable grade and speed datasets, we conducted research on the effect of grades on free flow speeds from two perspectives. First, the influence of grades on speed was analyzed from both quantitative and qualitative aspects. The analysis of the distributions of four typical types of speeds demonstrated a decreasing tendency as the speed increased. Steeper grades generated a more intense speed fluctuation in terms of the four types of speeds. Second, a model based on the Student's t-test was developed to evaluate the level of significant difference among speed series under neighboring grades. The Student's t-test demonstrated that adjacent grades do not significantly influence the speeds. In summary, speeds under different grades showed obviously different tendencies. The findings of this study can help transport authorities set more reasonable speed limits and improve the geometric design of interstates with grade variation constraints.
Vertical-cavity surface-emitting lasers: the applications
NASA Astrophysics Data System (ADS)
Morgan, Robert A.; Lehman, John A.; Hibbs-Brenner, Mary K.; Liu, Yue; Bristow, Julian P. G.
1997-05-01
In this paper, we focus on how vertical-cavity surface- emitting lasers (VCSELs) and arrays have led to many feasible advanced technological applications. Their intrinsic characteristics, performance, and producibility offer substantial advantages over alternative sources. Demonstrated performance of `commercial-grade' VCSELs include low operating powers (< 2 V, mAs), high speeds (3 dB BWs > 15 GHz), and high temperature operating ranges (10 K to 400 K and -55 degree(s)C to 125 degree(s)C, and T > 200 degree(s)C). Moreover, their robustness is manifest by high reliability in excess of 107 hours mean time between failures at room temperature and tenfold improvement over existing rad-hard LEDs. Hence, even these `commercial-grade' VCSELs offer potential within cryogenic and avionics/military or space environments. We have also demonstrated submilliamp ITH, stable, single-mode VCSELs utilized within bias-free 1-Gbit/s data links. These low- power VCSELs may also serve in applications from printers to low-cost atomic clocks. The greatest near-term VCSEL applications are upgrades to low-cost LEDs and high-grade copper wire in data links and sensors. Exploiting their surface-emitting geometry, VCSELs are also compatible with established multichip module packaging. Hence VCSELs and VCSEL arrays are ideal components for interconnect-intensive processing applications between and within computing systems.
System-Level Biochip for Impedance Sensing and Programmable Manipulation of Bladder Cancer Cells
Chuang, Cheng-Hsin; Huang, Yao-Wei; Wu, Yao-Tung
2011-01-01
This paper develops a dielectrophoretic (DEP) chip with multi-layer electrodes and a micro-cavity array for programmable manipulations of cells and impedance measurement. The DEP chip consists of an ITO top electrode, flow chamber, middle electrode on an SU-8 surface, micro-cavity arrays of SU-8 and distributed electrodes at the bottom of the micro-cavity. Impedance sensing of single cells could be performed as follows: firstly, cells were trapped in a micro-cavity array by negative DEP force provided by top and middle electrodes; then, the impedance measurement for discrimination of different stage of bladder cancer cells was accomplished by the middle and bottom electrodes. After impedance sensing, the individual releasing of trapped cells was achieved by negative DEP force using the top and bottom electrodes in order to collect the identified cells once more. Both cell manipulations and impedance measurement had been integrated within a system controlled by a PC-based LabVIEW program. In the experiments, two different stages of bladder cancer cell lines (grade III: T24 and grade II: TSGH8301) were utilized for the demonstration of programmable manipulation and impedance sensing; as the results show, the lower-grade bladder cancer cells (TSGH8301) possess higher impedance than the higher-grade ones (T24). In general, the multi-step manipulations of cells can be easily programmed by controlling the electrical signal in our design, which provides an excellent platform technology for lab-on-a-chip (LOC) or a micro-total-analysis-system (Micro TAS). PMID:22346685
Post-traumatic subtalar osteoarthritis: which grading system should we use?
de Muinck Keizer, Robert-Jan O; Backes, Manouk; Dingemans, Siem A; Goslings, J Carel; Schepers, Tim
2016-09-01
To assess and compare post-traumatic osteoarthritis following intra-articular calcaneal fractures, one must have a reliable grading system that consistently grades the post-traumatic changes of the joint. A reliable grading system aids in the communication between treating physicians and improves the interpretation of research. To date, there is no consensus on what grading system to use in the evaluation of post-traumatic subtalar osteoarthritis. The objective of this study was to determine and compare the inter- and intra-rater reliability of two grading systems for post-traumatic subtalar osteoarthritis. Four observers evaluated 50 calcaneal fractures at least one year after trauma on conventional oblique lateral, internally and externally rotated views, and graded post-traumatic subtalar osteoarthritis using the Kellgren and Lawrence Grading Scale (KLGS) and the Paley Grading System (PGS). Inter- and intra-rater reliability were calculated and compared. The inter-rater reliability showed an intra-class correlation (ICC) of 0.54 (95 % CI 0.40-0.67) for the KLGS and an ICC of 0.41 (95 % CI 0.26 - 0.57) for the PGS. This difference was not statistically significant. The intra-rater reliability showed a mean weighted kappa of 0.62 for both the KLGS and the PGS. There is no statistically significant difference in reliability between the Kellgren and Lawrence Grading System (KLGS) and the Paley Grading System (PGS). The PGS allows for an easy two-step approach making it easy for everyday clinical purposes. For research purposes however, the more detailed and widely used KLGS seems preferable.
Pictorial/Oral and Written Responses of First Grade Students: Can Aesthetic Growth Be Measured?
ERIC Educational Resources Information Center
Altieri, Jennifer
1995-01-01
Applies an aesthetic instrument to first-grade students' pictorial/oral and written responses to determine if significant aesthetic growth was demonstrated in responses collected over a three-month period. Compares students' written growth to growth demonstrated in pictorial/oral responses. Finds that pictorial and oral responses can serve as…
2013-05-01
Childhood Atypical Teratoid/Rhabdoid Tumor; Childhood Central Nervous System Choriocarcinoma; Childhood Central Nervous System Embryonal Tumor; Childhood Central Nervous System Germinoma; Childhood Central Nervous System Mixed Germ Cell Tumor; Childhood Central Nervous System Teratoma; Childhood Central Nervous System Yolk Sac Tumor; Childhood Choroid Plexus Tumor; Childhood Craniopharyngioma; Childhood Ependymoblastoma; Childhood Grade I Meningioma; Childhood Grade II Meningioma; Childhood Grade III Meningioma; Childhood High-grade Cerebellar Astrocytoma; Childhood High-grade Cerebral Astrocytoma; Childhood Infratentorial Ependymoma; Childhood Low-grade Cerebellar Astrocytoma; Childhood Low-grade Cerebral Astrocytoma; Childhood Medulloepithelioma; Childhood Mixed Glioma; Childhood Oligodendroglioma; Childhood Supratentorial Ependymoma; Extra-adrenal Paraganglioma; Recurrent Childhood Brain Stem Glioma; Recurrent Childhood Central Nervous System Embryonal Tumor; Recurrent Childhood Cerebellar Astrocytoma; Recurrent Childhood Cerebral Astrocytoma; Recurrent Childhood Ependymoma; Recurrent Childhood Medulloblastoma; Recurrent Childhood Pineoblastoma; Recurrent Childhood Spinal Cord Neoplasm; Recurrent Childhood Subependymal Giant Cell Astrocytoma; Recurrent Childhood Supratentorial Primitive Neuroectodermal Tumor; Recurrent Childhood Visual Pathway and Hypothalamic Glioma
Graft-versus-Host Disease of the Gut: A Histologic Activity Grading System and Validation.
Myerson, David; Steinbach, Gideon; Gooley, Ted A; Shulman, Howard M
2017-09-01
The pathologic interpretation of gut biopsies in hematopoietic cell transplant recipients to assess graft-versus-host disease (GVHD) is well accepted and supplements clinical and endoscopic findings. However, the histologic activity grading of GVHD is controversial, with attempts to predict prognosis or response to treatment largely unsuccessful. GVHD is being diagnosed earlier in its course, raising the possibility that the pathologic grading system can be profitably modified. We developed a histologic activity grading system designed to replace the commonly used modified Lerner grading systems. Our system stratifies the low-level Lerner grade I category into 4 activity grade categories, based on the average frequency of apoptotic cells. The results are expressed as ordinal categories: GVHD of minimal, mild, moderate, severe histologic activity, or severe histologic activity with destruction (activity grades 1 to 5). In a retrospective study, we studied 87 consecutive cases with 201 post-transplantation specimens (median, 48 days; range, 18 to 1479 days) of stomach, duodenum, and colorectum, which had been activity graded at the time of the original diagnosis. Most of the biopsies diagnosed as GVHD were low grade-minimal (11%) or mild (71%) histologic activity. We hypothesized that the higher activity grades would be associated with more therapeutic intervention. The odds of increased therapy in the combined all-site specimens were increased as activity grade increased (odds ratio, 2.9 [95% confidence interval {CI}, 1.9 to 4.5]; P = < .0001). Thus, our grading system was validated. To investigate whether the activity grade was associated with therapy within the formerly undivided Lerner grade I category, the analysis was restricted to these 174 all-site specimens. The validation result was similar (odds ratio, 3.1 [95% CI, 1.3 to 7.2]; P = .009). This result interestingly suggests that there is useful information hidden in the Lerner grade I category, which could potentially guide immediately actionable treatment decisions. This histologic activity grade system has been in use at our institution for over 2 years with good acceptance. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Mechanical grading of round timber beams
David W. Green; Thomas M. Gorman; James W. Evans; Joseph F. Murphy
2006-01-01
Current procedures used to sort round timber beams into structural grades rely on visual grading methods and property assignments based on modification of clear wood properties. This study provides the technical basis for mechanical grading of 228 mm (9 in.) diameter round timbers. Test results on 225 round Engelmann spruceâalpine firâlodgepole pine beams demonstrate...
The Ability to Read Is the Gateway to Success. K-3 Reading
ERIC Educational Resources Information Center
Foundation for Excellence in Education, 2017
2017-01-01
The goal of a Comprehensive K-3 Reading Policy is to establish intensive reading intervention for K- 3 students who are at risk of reading failure to help ensure they read on grade level by the end of third grade. The policy also requires third grade students to demonstrate sufficient reading skills for promotion to fourth grade. Retention can…
Pisoni, Stefano; Weiss, Thomas P.; Feurer, Thomas; Wäckerlin, Aneliia; Fuchs, Peter; Nishiwaki, Shiro; Zortea, Lukas; Tiwari, Ayodhya N.
2018-01-01
Abstract Compositional grading has been widely exploited in highly efficient Cu(In,Ga)Se2, CdTe, GaAs, quantum dot solar cells, and this strategy has the potential to improve the performance of emerging perovskite solar cells. However, realizing and maintaining compositionally graded perovskite absorber from solution processing is challenging. Moreover, the operational stability of graded perovskite solar cells under long‐term heat/light soaking has not been demonstrated. In this study, a facile partial ion‐exchange approach is reported to achieve compositionally graded perovskite absorber layers. Incorporating compositional grading improves charge collection and suppresses interface recombination, enabling to fabricate near‐infrared‐transparent perovskite solar cells with power conversion efficiency of 16.8% in substrate configuration, and demonstrate 22.7% tandem efficiency with 3.3% absolute gain when mechanically stacked on a Cu(In,Ga)Se2 bottom cell. Non‐encapsulated graded perovskite device retains over 93% of its initial efficiency after 1000 h operation at maximum power point at 60 °C under equivalent 1 sun illumination. The results open an avenue in exploring partial ion‐exchange to design graded perovskite solar cells with improved efficiency and stability. PMID:29593970
Fu, Fan; Pisoni, Stefano; Weiss, Thomas P; Feurer, Thomas; Wäckerlin, Aneliia; Fuchs, Peter; Nishiwaki, Shiro; Zortea, Lukas; Tiwari, Ayodhya N; Buecheler, Stephan
2018-03-01
Compositional grading has been widely exploited in highly efficient Cu(In,Ga)Se 2 , CdTe, GaAs, quantum dot solar cells, and this strategy has the potential to improve the performance of emerging perovskite solar cells. However, realizing and maintaining compositionally graded perovskite absorber from solution processing is challenging. Moreover, the operational stability of graded perovskite solar cells under long-term heat/light soaking has not been demonstrated. In this study, a facile partial ion-exchange approach is reported to achieve compositionally graded perovskite absorber layers. Incorporating compositional grading improves charge collection and suppresses interface recombination, enabling to fabricate near-infrared-transparent perovskite solar cells with power conversion efficiency of 16.8% in substrate configuration, and demonstrate 22.7% tandem efficiency with 3.3% absolute gain when mechanically stacked on a Cu(In,Ga)Se 2 bottom cell. Non-encapsulated graded perovskite device retains over 93% of its initial efficiency after 1000 h operation at maximum power point at 60 °C under equivalent 1 sun illumination. The results open an avenue in exploring partial ion-exchange to design graded perovskite solar cells with improved efficiency and stability.
Bringing Science Public Outreach to Elementary Schools
NASA Astrophysics Data System (ADS)
Miller, Lucas; Speck, A.; Tinnin, A.
2012-01-01
Many science "museums” already offer fantastic programs for the general public, and even some aimed at elementary school kids. However, these venues are usually located in large cities and are only occasionally used as tools for enriching science education in public schools. Here we present preliminary work to establish exciting educational enrichment environments for public schools that do not easily have access to such facilities. This program is aimed at motivating children's interest in science beyond what they learn in the classroom setting. In this program, we use the experience and experiments/demonstrations developed at a large science museum (in this case, The St. Louis Science Center) and take them into a local elementary school. At the same time, students from the University of Missouri are getting trained on how to present these outreach materials and work with the local elementary schools. Our pilot study has started with implementation of presentations/demonstrations at Benton Elementary School within the Columbia Public School district, Missouri. The school has recently adopted a STEM (Science, Technology, Engineering, and Mathematics) centered learning system throughout all grade levels (K-5), and is therefore receptive to this effort. We have implemented a program in which we have given a series of scientific demonstrations at each grade level's lunch hour. Further enrichment ideas and plans include: addition demonstrations, hands-on experiments, and question and answer sessions. However, the application of these events would be to compliment the curriculum for the appropriate grade level at that time. The focus of this project is to develop public communications which links science museums, college students and local public schools with an emphasis on encouraging college science majors to share their knowledge and to strengthen their ability to work in a public environment.
Multifunctional organic thin films and their electronic/optical properties
NASA Astrophysics Data System (ADS)
Shao, Yan
The concept of multifunctional organic thin films and their electronic/optical properties has been applied to organic functional device design, fabrication, and characterization. The organic devices involve organic light-emitting diodes (OLEDs) and organic photovoltaic devices (OPV) in this dissertation. In the research of graded junction structure of OLEDs, two kinds of naturally-formed graded junction (NFGJ) structures, sharp and shallow graded junctions, can be formed using single thermal evaporation boat loaded with uniformly mixed charge transport and light-emitting materials. OLEDs with NFGJ have been demonstrated in Chapter 3; the performance is comparable to the heterojunction OLEDs, but with better device lifetime. A novel method to prepare highly uniform mixed organic solid solutions through a high temperature and high-pressure fusion process has been demonstrated in Chapter 4. A series of fused organic solid solution (FOSS) compounds with NPD doped with different organic emitting dopants were prepared and DSC technique was utilized to determine the thermal characteristics. For the first time, the schematic phase diagram for this binary system has been obtained. High performance OLEDs of single color and white emission were fabricated and the device properties were characterized. In Chapter 5, an efficient photovoltaic heterojunction of tetracene and fullerene has been investigated and high performance organic solar cells have been demonstrated by thermal deposition and successive heat treatment. The preliminary conclusion for this enhancement is discussed and supported by atomic force microscopy images, absorption spectra and x-ray diffraction analysis. Additionally, an effective organic photovoltaic heterojunction based on the typical triplet material PtOEP was demonstrated. It is believed that introducing appropriate organic materials with long exciton lifetime is a very promising way to improve photovoltaic performance.
Ultrasonic scanning system for imaging flaw growth in composites
NASA Technical Reports Server (NTRS)
Kiraly, L. J.; Meyn, E. H.
1982-01-01
A system for measuring and visually representing damage in composite specimens while they are being loaded was demonstrated. It uses a hobbiest grade microcomputer system to control data taking and image processing. The system scans operator selected regions of the specimen while it is under load in a tensile test machine and measures internal damage by the attenuation of a 2.5 MHz ultrasonic beam passed through the specimen. The microcomputer dynamically controls the position of ultrasonic transducers mounted on a two axis motor driven carriage. As many as 65,536 samples can be taken and filed on a floppy disk system in less than four minutes.
Endometrial stromal tumours revisited: an update based on the 2014 WHO classification.
Ali, Rola H; Rouzbahman, Marjan
2015-05-01
Endometrial stromal tumours (EST) are rare tumours of endometrial stromal origin that account for less than 2% of all uterine tumours. Recent cytogenetic and molecular advances in this area have improved our understanding of ESTs and helped refine their classification into more meaningful categories. Accordingly, the newly released 2014 WHO classification system recognises four categories: endometrial stromal nodule (ESN), low-grade endometrial stromal sarcoma (LGESS), high-grade endometrial stromal sarcoma (HGESS) and undifferentiated uterine sarcoma (UUS). At the molecular level, these tumours may demonstrate a relatively simple karyotype with a defining chromosomal rearrangement (as in the majority of ESNs, LGESSs and YWHAE-rearranged HGESS) or demonstrate complex cytogenetic aberrations lacking specific rearrangements (as in UUSs). Herein we provide an update on this topic aimed at the practicing pathologist. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Silicon halide-alkali metal flames as a source of solar grade silicon
NASA Technical Reports Server (NTRS)
Olsen, D. B.; Miller, W. J.
1979-01-01
The feasibility of using alkali metal-silicon halide diffusion flames to produce solar-grade silicon in large quantities and at low cost is demonstrated. Prior work shows that these flames are stable and that relatively high purity silicon can be produced using Na + SiCl4 flames. Silicon of similar purity is obtained from Na + SiF4 flames although yields are lower and product separation and collection are less thermochemically favored. Continuous separation of silicon from the byproduct alkali salt was demonstrated in a heated graphite reactor. The process was scaled up to reduce heat losses and to produce larger samples of silicon. Reagent delivery systems, scaled by a factor of 25, were built and operated at a production rate of 0.5 kg Si/h. Very rapid reactor heating rates are observed with wall temperatures reaching greater than 2000 K. Heat release parameters were measured using a cooled stainless steel reactor tube. A new reactor was designed.
78 FR 60331 - Privacy Act of 1974: System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-01
... on Position Classification Appeals, Job Grading Appeals, Retained Grade or Pay Appeals, Fair Labor..., Job Grading Appeals, Retained Grade or Pay Appeals, Fair Labor Standard Act (FLSA) Claims and... appeal or a job grading appeal with the U.S. Office of Personnel Management, Merit System Accountability...
... medlineplus.gov/ency/patientinstructions/000920.htm Gleason grading system To use the sharing features on this page, ... score of between 5 and 7. Gleason Grading System Sometimes, it can be hard to predict how ...
Texture analysis of tissues in Gleason grading of prostate cancer
NASA Astrophysics Data System (ADS)
Alexandratou, Eleni; Yova, Dido; Gorpas, Dimitris; Maragos, Petros; Agrogiannis, George; Kavantzas, Nikolaos
2008-02-01
Prostate cancer is a common malignancy among maturing men and the second leading cause of cancer death in USA. Histopathological grading of prostate cancer is based on tissue structural abnormalities. Gleason grading system is the gold standard and is based on the organization features of prostatic glands. Although Gleason score has contributed on cancer prognosis and on treatment planning, its accuracy is about 58%, with this percentage to be lower in GG2, GG3 and GG5 grading. On the other hand it is strongly affected by "inter- and intra observer variations", making the whole process very subjective. Therefore, there is need for the development of grading tools based on imaging and computer vision techniques for a more accurate prostate cancer prognosis. The aim of this paper is the development of a novel method for objective grading of biopsy specimen in order to support histopathological prognosis of the tumor. This new method is based on texture analysis techniques, and particularly on Gray Level Co-occurrence Matrix (GLCM) that estimates image properties related to second order statistics. Histopathological images of prostate cancer, from Gleason grade2 to Gleason grade 5, were acquired and subjected to image texture analysis. Thirteen texture characteristics were calculated from this matrix as they were proposed by Haralick. Using stepwise variable selection, a subset of four characteristics were selected and used for the description and classification of each image field. The selected characteristics profile was used for grading the specimen with the multiparameter statistical method of multiple logistic discrimination analysis. The subset of these characteristics provided 87% correct grading of the specimens. The addition of any of the remaining characteristics did not improve significantly the diagnostic ability of the method. This study demonstrated that texture analysis techniques could provide valuable grading decision support to the pathologists, concerning prostate cancer prognosis.
NASA Astrophysics Data System (ADS)
Wang, Dongsheng; Zou, Jizuo; Yang, Yunping; Dong, Jianhua; Zhang, Yuanxiang
1996-10-01
A high-speed automatic agricultural produce grading and sorting system using color CCD and new color identification algorithm has been developed. In a typical application, the system can sort almonds into tow output grades according to their color. Almonds ar rich in 18 kinds of amino acids and 13 kinds of micro minerals and vitamins and can be made into almond drink. In order to ensure the drink quality, almonds must be sorted carefully before being made into a drink. Using this system, almonds can be sorted into two grades: up to grade and below grade almonds or foreign materials. A color CCD inspects the almonds passing on a conveyor of rotating rollers, a color identification algorithm grades almonds and distinguishes foreign materials from almonds. Employing an elaborately designed mechanism, the below grade almonds and foreign materials can be removed effectively from the raw almonds. This system can be easily adapted for inspecting and sorting other kinds of agricultural produce such as peanuts, beans tomatoes and so on.
ERIC Educational Resources Information Center
PELLA, MILTON O.; ZIEGLER, ROBERT E.
THE RELATIVE EFFECTIVENESS OF TWO TYPES OF MECHANICAL MODELS FOR TEACHING ELEMENTARY SCHOOL STUDENTS TO USE THE PARTICLE IDEA OF MATTER TO EXPLAIN CERTAIN PHYSICAL PHENOMENA WAS INVESTIGATED. SUBJECTS WERE RANDOMLY SELECTED FROM STUDENTS ENROLLED IN GRADES TWO THROUGH SIX IN A SCHOOL SYSTEM. A SERIES OF DEMONSTRATIONS AND RELATED QUESTIONS WERE…
Liberal Grading Improves Evaluations but Not Performance.
ERIC Educational Resources Information Center
Vasta, Ross; Sarmiento, Robert F.
1979-01-01
The effects of examination grades on undergraduates' study behaviors, attendance, and evaluations of instruction were examined. Liberal grading was found to result in higher evaluations of course and instructor but had no demonstrable effect on studying or attendance. The implications of these findings and alternative interpretations are…
Arkansas Music Curriculum Framework 1997.
ERIC Educational Resources Information Center
Arkansas State Dept. of Education, Little Rock.
This framework for music contains four instructional strands. Each strand has content standards and cumulative student learning expectations for grades K-4, grades 5-8, and grades 9-12. The strands are: (1) "Create and Perform," in which students will demonstrate musical competency through creating and performing; (2) "Listen…
[Grading of gynecological tumors : Current aspects].
Horn, L-C; Mayr, D; Brambs, C E; Einenkel, J; Sändig, I; Schierle, K
2016-07-01
Histopathological assessment of the tumor grade and cell type is central to the management and prognosis of various gynecological malignancies. Conventional grading systems for squamous carcinomas and adenocarcinomas of the vulva, vagina and cervix are poorly defined. For endometrioid tumors of the female genital tract as well as for mucinous endometrial, ovarian and seromucinous ovarian carcinomas, the 3‑tiered FIGO grading system is recommended. For uterine neuroendocrine tumors the grading system of the gastrointestinal counterparts has been adopted. Uterine leiomyosarcomas are not graded. Endometrial stromal sarcomas are divided into low and high grades, based on cellular morphology, immunohistochemical and molecular findings. A chemotherapy response score was established for chemotherapeutically treated high-grade serous pelvic cancer. For non-epithelial ovarian malignancies, only Sertoli-Leydig cell tumors and immature teratomas are graded. At this time molecular profiling has no impact on the grading of tumors of the female genital tract.
Cao, Feng; Zhang, Chao; Vo Doan, Tat Thang; Li, Yao; Sangi, Daniyal Haider; Koh, Jie Sheng; Huynh, Ngoc Anh; Bin Aziz, Mohamed Fareez; Choo, Hao Yu; Ikeda, Kazuo; Abbeel, Pieter; Maharbiz, Michel M; Sato, Hirotaka
2014-01-01
In this study, a biological microactuator was demonstrated by closed-loop motion control of the front leg of an insect (Mecynorrhina torquata, beetle) via electrical stimulation of the leg muscles. The three antagonistic pairs of muscle groups in the front leg enabled the actuator to have three degrees of freedom: protraction/retraction, levation/depression, and extension/flexion. We observed that the threshold amplitude (voltage) required to elicit leg motions was approximately 1.0 V; thus, we fixed the stimulation amplitude at 1.5 V to ensure a muscle response. The leg motions were finely graded by alternation of the stimulation frequencies: higher stimulation frequencies elicited larger leg angular displacement. A closed-loop control system was then developed, where the stimulation frequency was the manipulated variable for leg-muscle stimulation (output from the final control element to the leg muscle) and the angular displacement of the leg motion was the system response. This closed-loop control system, with an optimized proportional gain and update time, regulated the leg to set at predetermined angular positions. The average electrical stimulation power consumption per muscle group was 148 µW. These findings related to and demonstrations of the leg motion control offer promise for the future development of a reliable, low-power, biological legged machine (i.e., an insect-machine hybrid legged robot).
The Grading System: Does an "A" Really Equal Learning?
ERIC Educational Resources Information Center
Haley, Beverly
1988-01-01
Good grades on a report card do not necessarily mean the material has been comprehended. This article examines the relative worth of grades; extra credit assignments; categorizing students into A, B, or C boxes; and the role of parental pressures for higher grades. Grading systems should be subordinate to true learning motivation. (MLH)
Job Grading System for Trades and Labor Occupations. Part II.
ERIC Educational Resources Information Center
Civil Service Commission, Washington, DC. Bureau of Policies and Standards.
Three new standards (telephone mechanic, electroplater, and animal caretaker) for grading jobs under the Federal Wage System are cited. There is an alphabetical listing by job for published job grading standards, an occupational code-structure index for published grading standards, and a list of 61 jobs by published job grading standard with…
Predicting Grades from an English Language Assessment: The Importance of Peeling the Onion
ERIC Educational Resources Information Center
Bridgeman, Brent; Cho, Yeonsuk; DiPietro, Stephen
2016-01-01
Data from 787 international undergraduate students at an urban university in the United States were used to demonstrate the importance of separating a sample into meaningful subgroups in order to demonstrate the ability of an English language assessment to predict the first-year grade point average (GPA). For example, when all students were pooled…
Preliminary work in developing sawbolt grading systems for white oak
Everette D. Rast; Everette D. Rast
1971-01-01
This paper is principally a description of one technique used in the development of white oak (Quercus alba L.) sawbolt grades--not a final sawbolt grading system for the species over its range. This technique can be used by anyone in developing other bolt-grade specifications or in refining the system presented in this paper.
Specifications-Based Grading in an Introduction to Proofs Course
ERIC Educational Resources Information Center
Williams, Kristopher
2018-01-01
This article describes a system of specifications-based grading used in an introduction to proofs course. The system was introduced to address two issues that arose in the course: how to spend less time grading and how to encourage use of feedback. We describe the implementation of the system and the results on grading and on students.
Montgomery, D H; Ververis, J J; McGorisk, G; Frohwein, S; Martin, R P; Taylor, W R
1996-01-01
This study sought to prospectively observe the morphologic and clinical natural history of severe atherosclerotic disease of the thoracic aorta as defined by transesophageal echocardiography. Atherosclerosis of the thoracic aorta has been shown to be highly associated with risk for embolic events in transesophageal studies, but the natural history of the disease under clinical conditions has not been reported. During a 20-month period, 191 of 264 patients undergoing transesophageal echocardiography had adequate visualization of the aorta to allow atherosclerotic severity to be graded as follows: grade I = normal (44 patients); grade II = intimal thickening (52 patients); grade III = atheroma < 5 mm (62 patients); grade IV = atheroma > or = 5 mm (19 patients); grade V = mobile lesion (14 patients). All available patients with grades IV (8 patients) and V (10 patients) disease as well as a subgroup of 12 patients with grade III disease had follow-up transesophageal echocardiographic studies (mean [+/- SD] 11.7 +/- 0.9 months, range 6 to 22). Of 30 patients undergoing follow-up transesophageal echocardiographic studies, 20 (66%) had no change in atherosclerotic severity grade. Of the remaining 10 patients, atherosclerotic severity progressed one grade in 7 and decreased in 3 with resolved mobile lesions. Of 18 patients with grade IV or V disease of the aorta who underwent a follow-up study, 11 (61%) demonstrated formation of new mobile lesions. Of 10 patients with grade V disease on initial study who underwent follow-up study, 7 (70%) demonstrated resolution of a specific previously documented mobile lesion. However, seven patients (70%) with grade V disease also demonstrated development of a new mobile lesion. Of 33 patients with grade IV or V disease, 8 (24%) died during the study period, and 1 (3%) had a clinical embolic event. The presence of severe atherosclerotic disease of the thoracic aorta as defined by transesophageal echocardiography is associated with a high mortality rate. Although the morphologic natural history of the disease process itself is marked by stability over a 1-year period, individual lesion morphology is dynamic, with formation and resolution of mobile components occurring frequently over the same period. The dynamic nature of individual lesion morphology potentially enhances the possibility of developing a successful therapeutic strategy.
Papaya drying and waste conversion system. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-02-12
This project, performed under United States Department of Energy Small-scale Appropriate Energy Technology Grant, involves demonstration of an integrated system using solar energy to process off-grade or reject fruit into marketable food products. The integrated system consists of three phases: (1) solar dehydration of usable fruit; (2) solar vacuum distillation of fermented wastes (peelings, rinds, skins, and seeds) to produce an ethanol fuel to use as a backup source of heat for dehydration; and (3) land reclamation by mixing stillage and compost with volcanic cinder and ash to produce on marginal land a rich soil suitable for growing more cropsmore » to dry. Although the system is not 100% complete the investigators have demonstrated that a small business can efficiently use solar energies in an integrated fashion to process waste into food, improve the quality of the land, and provide meaningful jobs in a region of very high unemployment.« less
Evaluating the impacts of grades on vehicular speeds on interstate highways
Li, Zhibin; Wang, Yinhai; Cui, Zhiyong; Shi, Chaojian; Wu, Huafeng
2017-01-01
Grade variation on interstate highways affects the roadway geometric design, vehicle performance and driver behavior, thus possibly exerting an unexpected effect on vehicular speed. Hence, determining the internal relationship between grade and speed is important and useful for drivers, traffic regulators and other traffic participants. However, the problem with performing this research is the lack of large-scale gradient and speed data. Google Earth (GE) provides an application programming interface for extracting elevation data worldwide. The elevation dataset from GE can be easily converted to grade data. In addition, our team has collected and stored speed series data for different freeways over several years. Based on the above obtainable grade and speed datasets, we conducted research on the effect of grades on free flow speeds from two perspectives. First, the influence of grades on speed was analyzed from both quantitative and qualitative aspects. The analysis of the distributions of four typical types of speeds demonstrated a decreasing tendency as the speed increased. Steeper grades generated a more intense speed fluctuation in terms of the four types of speeds. Second, a model based on the Student’s t-test was developed to evaluate the level of significant difference among speed series under neighboring grades. The Student’s t-test demonstrated that adjacent grades do not significantly influence the speeds. In summary, speeds under different grades showed obviously different tendencies. The findings of this study can help transport authorities set more reasonable speed limits and improve the geometric design of interstates with grade variation constraints. PMID:28863157
2017-05-01
Protecting And Bonding Reinforcing Steel In Cement -Based Composites, Corrosion 2009, Atlanta, GA, 22-26 March 2009. 7. Hock, V., O. Marshall, S...ER D C/ CE RL T R- 17 -1 3 DoD Corrosion Prevention and Control Program Demonstration and Validation of Stainless Steel Materials for...ERDC/CERL TR-17-13 May 2017 Demonstration and Validation of Stainless Steel Materials for Critical Above-Grade Piping in Highly Corrosive
Automated detection of fundus photographic red lesions in diabetic retinopathy.
Larsen, Michael; Godt, Jannik; Larsen, Nicolai; Lund-Andersen, Henrik; Sjølie, Anne Katrin; Agardh, Elisabet; Kalm, Helle; Grunkin, Michael; Owens, David R
2003-02-01
To compare a fundus image-analysis algorithm for automated detection of hemorrhages and microaneurysms with visual detection of retinopathy in patients with diabetes. Four hundred fundus photographs (35-mm color transparencies) were obtained in 200 eyes of 100 patients with diabetes who were randomly selected from the Welsh Community Diabetic Retinopathy Study. A gold standard reference was defined by classifying each patient as having or not having diabetic retinopathy based on overall visual grading of the digitized transparencies. A single-lesion visual grading was made independently, comprising meticulous outlining of all single lesions in all photographs and used to develop the automated red lesion detection system. A comparison of visual and automated single-lesion detection in replicating the overall visual grading was then performed. Automated red lesion detection demonstrated a specificity of 71.4% and a resulting sensitivity of 96.7% in detecting diabetic retinopathy when applied at a tentative threshold setting for use in diabetic retinopathy screening. The accuracy of 79% could be raised to 85% by adjustment of a single user-supplied parameter determining the balance between the screening priorities, for which a considerable range of options was demonstrated by the receiver-operating characteristic (area under the curve 90.3%). The agreement of automated lesion detection with overall visual grading (0.659) was comparable to the mean agreement of six ophthalmologists (0.648). Detection of diabetic retinopathy by automated detection of single fundus lesions can be achieved with a performance comparable to that of experienced ophthalmologists. The results warrant further investigation of automated fundus image analysis as a tool for diabetic retinopathy screening.
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. A. Carlson
2006-02-23
The 1607-D4 Septic System was a septic tank and tile field that received sanitary sewage from the 115-D/DR Gas Recirculation Facility. This septic system operated from 1944 to 1968. Decommissioning took place in 1985 and 1986 when all above-grade features were demolished and the tank backfilled. The results of verification sampling demonstrated that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also showed that residual contaminant concentrations are protective of groundwater and the Columbia River.
ERIC Educational Resources Information Center
Education Development Center, Inc., 2016
2016-01-01
In the domain of "Operations & Algebraic Thinking," Common Core State Standards indicate that in kindergarten, first grade, and second grade, children should demonstrate and expand their ability to understand, represent, and solve problems using the operations of addition and subtraction, laying the foundation for operations using…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varga, Zoltan; Cserhati, Adrienn; Kelemen, Gyoengyi
2011-07-15
Purpose: To analyze the risk of radiogenic lung damage in breast cancer patients after conformal radiotherapy and different forms of systemic treatment. Methods and Materials: In 328 patients receiving sequential taxane-based chemotherapy, concomitant hormone therapy (tamoxifen or aromatase inhibitors), or no adjuvant systemic therapy, symptomatic and asymptomatic lung sequelae were prospectively evaluated via the detection of visible CT abnormalities, 3 months or 1 year after the completion of the radiotherapy. Results: Significant positive associations were detected between the development of both pneumonitis and fibrosis of Grade 1 and patient age, ipsilateral mean lung dose, volume of the ipsilateral lung receivingmore » 20 Gy, and irradiation of the regional lymph nodes. In multivariate analysis, age and mean lung dose proved to be independent predictors of early (odds ratio [OR] = 1.035, 95% confidence interval [CI] 1.011-1.061 and OR = 1.113, 95% CI 1.049-1.181, respectively) and late (OR = 1.074, 95% CI 1.042-1.107 and OR = 1.207, 95% CI 1.124-1.295, respectively) radiogenic lung damage, whereas the role of systemic therapy was significant in the development of Grade 1 lung fibrosis (p = 0.01). Among the various forms of systemic therapy, tamoxifen increased the risk of late lung sequelae (OR = 2.442, 95% CI 1.120-5.326, p = 0.025). No interaction was demonstrated between the administration of systemic therapy and the other above-mentioned parameters as regards the risk of radiogenic lung damage. Conclusions: Our analyses demonstrate the independent role of concomitant tamoxifen therapy in the development of radiogenic lung fibrosis but do not suggest such an effect for the other modes of systemic treatment.« less
Prostate cancer: from Gleason scoring to prognostic grade grouping.
Montironi, Rodolfo; Santoni, Matteo; Mazzucchelli, Roberta; Burattini, Luciano; Berardi, Rossana; Galosi, Andrea B; Cheng, Liang; Lopez-Beltran, Antonio; Briganti, Alberto; Montorsi, Francesco; Scarpelli, Marina
2016-01-01
The Gleason grading system was developed in the late 1960s by Dr. Donald F. Gleason. Due to changes in prostatic adenocarcinoma (PAC) detection and treatment, newer technologies to better characterize prostatic pathology, subsequently described variants of PAC and further data relating various morphologic patterns to prognosis, the application of the Gleason grading system changed substantially in surgical pathology. First in 2005 and more recently in 2014, consensus conferences were held to update PAC grading. Here, we review of the successive changes in the grading of PAC from the original system, with emphasis on the newest prognostic grade grouping.
Straub, Anthony P; Elimelech, Menachem
2017-11-07
Low-grade heat energy from sources below 100 °C is available in massive quantities around the world, but cannot be converted to electricity effectively using existing technologies due to variability in the heat output and the small temperature difference between the source and environment. The recently developed thermo-osmotic energy conversion (TOEC) process has the potential to harvest energy from low-grade heat sources by using a temperature difference to create a pressurized liquid flux across a membrane, which can be converted to mechanical work via a turbine. In this study, we perform the first analysis of energy efficiency and the expected performance of the TOEC technology, focusing on systems utilizing hydrophobic porous vapor-gap membranes and water as a working fluid. We begin by developing a framework to analyze realistic mass and heat transport in the process, probing the impact of various membrane parameters and system operating conditions. Our analysis reveals that an optimized system can achieve heat-to-electricity energy conversion efficiencies up to 4.1% (34% of the Carnot efficiency) with hot and cold working temperatures of 60 and 20 °C, respectively, and an operating pressure of 5 MPa (50 bar). Lower energy efficiencies, however, will occur in systems operating with high power densities (>5 W/m 2 ) and with finite-sized heat exchangers. We identify that the most important membrane properties for achieving high performance are an asymmetric pore structure, high pressure resistance, a high porosity, and a thickness of 30 to 100 μm. We also quantify the benefits in performance from utilizing deaerated water streams, strong hydrodynamic mixing in the membrane module, and high heat exchanger efficiencies. Overall, our study demonstrates the promise of full-scale TOEC systems to extract energy from low-grade heat and identifies key factors for performance optimization moving forward.
Chinese approaches to understanding and building resilience in at-risk children and adolescents.
Lee, Tak-Yan; Shek, Daniel T L; Kwong, Wai-Man
2007-04-01
This article discusses the prevailing Chinese belief systems that have bearings on the perception and practices of promoting resilience among children and youth in a major city in China. It briefly describes a huge social intervention program entitled "Understanding the Adolescent Project" to combat the problems among grade 7 students identified as adolescents at risk from 2001 to 2004 in Hong Kong Special Administrative Region. A critical review of the problems encountered by social workers in the delivery of the program is presented to support the move to provide the preventive program for grade 4 students with clinical symptoms on a screening tool for identification of at-risk status. Starting in 2005, a large-scale positive youth development program was being developed for all secondary one to three (grades 7 to 9) students. Encouraging results of the evaluation studies demonstrated the effectiveness of this new preventive program, entitled Positive Adolescent Training through Holistic Social Programs.
Ramaswamy, Vidya; Piskorowski, Wilhelm; Fitzgerald, Mark; Hamerink, Howard A; Stefanac, Stephen; Greene, Rachel; Lantz, Marilyn S
2016-10-01
Since 2006, the University of Michigan School of Dentistry has used a 13-point measure of overall competence instrument to assess fourth-year dental students' end-rotation performance at community clinics. The aim of this study was to assess the reliability and validity of this instrument used by preceptors to rate students' overall competence during community-based dental education experiences. The measure was analyzed using performance ratings for all fourth-year DDS students in the graduating classes of 2012 and 2013 (combined n=201). The results were that interrater agreement was satisfactory and the measure scored high for internal consistency; also, the measure loaded highly on a single overall competence factor. Ratings on this measure did not correlate with students' final cumulative dental school GPA, but showed a significant positive correlation with their fourth-year fall patient management grades (which signify students' conscientiousness in managing patients and their families in a professional and ethical manner). There were differences in grading systems between the 2012 cohort (which used a pass/fail system) and the 2013 cohort (which used a letter grade system) and the mean ratings they received (higher for the 2013 cohort). Overall, the study found that the 13-point measure demonstrated excellent reliability and validity, suggesting it is useful in determining a student's clinical competence in these settings.
Osmotic Heat Engine Using Thermally Responsive Ionic Liquids.
Zhong, Yujiang; Wang, Xinbo; Feng, Xiaoshuang; Telalovic, Selvedin; Gnanou, Yves; Huang, Kuo-Wei; Hu, Xiao; Lai, Zhiping
2017-08-15
The osmotic heat engine (OHE) is a promising technology for converting low grade heat to electricity. Most of the existing studies have focused on thermolytic salt systems. Herein, for the first time, we proposed to use thermally responsive ionic liquids (TRIL) that have either an upper critical solution temperature (UCST) or lower critical solution temperature (LCST) type of phase behavior as novel thermolytic osmotic agents. Closed-loop TRIL-OHEs were designed based on these unique phase behaviors to convert low grade heat to work or electricity. Experimental studies using two UCST-type TRILs, protonated betaine bis(trifluoromethyl sulfonyl)imide ([Hbet][Tf 2 N]) and choline bis(trifluoromethylsulfonyl)imide ([choline][Tf 2 N]) showed that (1) the specific energy of the TRIL-OHE system could reach as high as 4.0 times that of the seawater and river water system, (2) the power density measured from a commercial FO membrane reached up to 2.3 W/m 2 , and (3) the overall energy efficiency reached up to 2.6% or 18% of the Carnot efficiency at no heat recovery and up to 10.5% or 71% of the Carnet efficiency at 70% heat recovery. All of these results clearly demonstrated the great potential of using TRILs as novel osmotic agents to design high efficient OHEs for recovery of low grade thermal energy to work or electricity.
An Effective Terrain Aided Navigation for Low-Cost Autonomous Underwater Vehicles.
Zhou, Ling; Cheng, Xianghong; Zhu, Yixian; Dai, Chenxi; Fu, Jinbo
2017-03-25
Terrain-aided navigation is a potentially powerful solution for obtaining submerged position fixes for autonomous underwater vehicles. The application of terrain-aided navigation with high-accuracy inertial navigation systems has demonstrated meter-level navigation accuracy in sea trials. However, available sensors may be limited depending on the type of the mission. Such limitations, especially for low-grade navigation sensors, not only degrade the accuracy of traditional navigation systems, but further impact the ability to successfully employ terrain-aided navigation. To address this problem, a tightly-coupled navigation is presented to successfully estimate the critical sensor errors by incorporating raw sensor data directly into an augmented navigation system. Furthermore, three-dimensional distance errors are calculated, providing measurement updates through the particle filter for absolute and bounded position error. The development of the terrain aided navigation system is elaborated for a vehicle equipped with a non-inertial-grade strapdown inertial navigation system, a 4-beam Doppler Velocity Log range sensor and a sonar altimeter. Using experimental data for navigation performance evaluation in areas with different terrain characteristics, the experiment results further show that the proposed method can be successfully applied to the low-cost AUVs and significantly improves navigation performance.
An Effective Terrain Aided Navigation for Low-Cost Autonomous Underwater Vehicles
Zhou, Ling; Cheng, Xianghong; Zhu, Yixian; Dai, Chenxi; Fu, Jinbo
2017-01-01
Terrain-aided navigation is a potentially powerful solution for obtaining submerged position fixes for autonomous underwater vehicles. The application of terrain-aided navigation with high-accuracy inertial navigation systems has demonstrated meter-level navigation accuracy in sea trials. However, available sensors may be limited depending on the type of the mission. Such limitations, especially for low-grade navigation sensors, not only degrade the accuracy of traditional navigation systems, but further impact the ability to successfully employ terrain-aided navigation. To address this problem, a tightly-coupled navigation is presented to successfully estimate the critical sensor errors by incorporating raw sensor data directly into an augmented navigation system. Furthermore, three-dimensional distance errors are calculated, providing measurement updates through the particle filter for absolute and bounded position error. The development of the terrain aided navigation system is elaborated for a vehicle equipped with a non-inertial-grade strapdown inertial navigation system, a 4-beam Doppler Velocity Log range sensor and a sonar altimeter. Using experimental data for navigation performance evaluation in areas with different terrain characteristics, the experiment results further show that the proposed method can be successfully applied to the low-cost AUVs and significantly improves navigation performance. PMID:28346346
Membrane-free battery for harvesting low-grade thermal energy.
Yang, Yuan; Loomis, James; Ghasemi, Hadi; Lee, Seok Woo; Wang, Yi Jenny; Cui, Yi; Chen, Gang
2014-11-12
Efficient and low-cost systems are desired to harvest the tremendous amount of energy stored in low-grade heat sources (<100 °C). An attractive approach is the thermally regenerative electrochemical cycle (TREC), which uses the dependence of electrode potential on temperature to construct a thermodynamic cycle for direct heat-to-electricity conversion. By varying the temperature, an electrochemical cell is charged at a lower voltage than discharged; thus, thermal energy is converted to electricity. Recently, a Prussian blue analog-based system with high efficiency has been demonstrated. However, the use of an ion-selective membrane in this system raises concerns about the overall cost, which is crucial for waste heat harvesting. Here, we report on a new membrane-free battery with a nickel hexacyanoferrate (NiHCF) cathode and a silver/silver chloride anode. The system has a temperature coefficient of -0.74 mV K(-1). When the battery is discharged at 15 °C and recharged at 55 °C, thermal-to-electricity conversion efficiencies of 2.6% and 3.5% are achieved with assumed heat recuperation of 50% and 70%, respctively. This work opens new opportunities for using membrane-free electrochemical systems to harvest waste heat.
User's guide to UGRS: the Ultimate Grading and Remanufacturing System (version 5.0).
John Moody; Charles J. Gatchell; Elizabeth S. Walker; Powsiri Klinkhachorn
1998-01-01
The Ultimate Grading and Remanufacturing System (UGRS) is the latest generation of advanced computer programs for lumber grading. It is designed to be a training and research tool that allows grading of lumber according to 1998 NHLA rules and remanufacturing for maximum dollar value. A 32-bit application that runs under all Microsoft Windows operating systems, UGRS...
Richard W. Haynes; Roger D. Fight
2004-01-01
Grade-specific price projections were once again developed for Douglas-fir, coast hem-fir, inland hem-fir, and ponderosa pine lumber. These grade-specific price projections can be used to demonstrate the returns to land management of practices that lead to high-quality logs that produce a larger proportion of high grades of lumber. The price ratios among low, medium,...
Furnes, Bjarte; Samuelsson, Stefan
2010-01-01
In this study, the relationship between latent constructs of phonological awareness (PA) and rapid automatized naming (RAN) were investigated and related to later measures of reading and spelling in children learning to read in different alphabetic writing systems (i.e., Norwegian/Swedish vs. English). 750 U.S./Australian children and 230 Scandinavian children were followed longitudinally between kindergarten and 2nd grade. PA and RAN were measured in kindergarten and Grade 1, while word recognition, phonological decoding, and spelling were measured in kindergarten, Grade 1, and Grade 2. In general, high stability was observed for the various reading and spelling measures, such that little additional variance was left open for PA and RAN. However, results demonstrated that RAN was more related to reading than spelling across orthographies, with the opposite pattern shown for PA. In addition, tests of measurement invariance show that the factor loadings of each observed indicator on the latent PA factor was the same across U.S./Australia and Scandinavia. Similar findings were obtained for RAN. In general, tests of structural invariance show that models of early literacy development are highly transferable across languages. PMID:21359098
Nakada, Izumi; Nakamura, Ichiro; Juji, Takuo; Ito, Katsumi; Matsumoto, Takumi
2015-09-01
Compensatory hindfoot alignment for deformities at the knee level has been demonstrated in patients with knee osteoarthritis. However, this phenomenon has not been elucidated in patients with rheumatoid arthritis (RA). The aim of this study is to investigate the relationship between knee deformity and hindfoot alignment and the effect of subtalar joint destruction in patients with RA. We retrospectively investigated RA patients (110 patients, 205 limbs) using radiographs in the standing anteroposterior knee, standing lateral foot, and hindfoot alignment views. The grade of destruction at the knee and subtalar joints was assigned using Larsen's grading system. The correlation between the femorotibial and tibiocalcaneal angles and the effect of joint destruction on this correlation were analyzed using Pearson's correlation coefficients. There was moderate correlation between the femorotibial and tibiocalcaneal angles in a group of knees with a Larsen grade of ≥ 4 (r = 0.544, p = 0.0239). This correlation was stronger in a group with less damaged subtalar joints with a Larsen grade of ≤ 3 (r = 0.705, p = 0.0049). These findings emphasized the importance of examining foot and ankles in patients with RA who undergo total knee arthroplasty.
Expression of aquaporin8 in human astrocytomas: Correlation with pathologic grade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Shu-juan; Wang, Ke-jian; Gan, Sheng-wei
2013-10-11
Highlights: •AQP8 is mainly distributed in the cytoplasm of human astrocytoma cells. •AQP8 over-expressed in human astrocytomas, especially glioblastoma. •The up-regulation of AQP8 is related to the pathological grade of human astrocytomas. •AQP8 may contribute to the growth and proliferation of astrocytomas. -- Abstract: Aquaporin8 (AQP8), a member of the aquaporin (AQP) protein family, is weakly distributed in mammalian brains. Previous studies on AQP8 have focused mainly on the digestive and the reproductive systems. AQP8 has a pivotal role in keeping the fluid and electrolyte balance. In this study, we investigated the expression changes of AQP8 in 75 cases ofmore » human brain astrocytic tumors using immunohistochemistry, Western blotting, and reverse transcription polymerase chain reaction. The results demonstrated that AQP8 was mainly distributed in the cytoplasm of astrocytoma cells. The expression levels and immunoreactive score of AQP8 protein and mRNA increased in low-grade astrocytomas, and further increased in high-grade astrocytomas, especially in glioblastoma. Therefore, AQP8 may contribute to the proliferation of astrocytomas, and may be a biomarker and candidate therapy target for patients with astrocytomas.« less
Urrutia, Julio; Besa, Pablo; Campos, Mauricio; Cikutovic, Pablo; Cabezon, Mario; Molina, Marcelo; Cruz, Juan Pablo
2016-09-01
Grading inter-vertebral disc degeneration (IDD) is important in the evaluation of many degenerative conditions, including patients with low back pain. Magnetic resonance imaging (MRI) is considered the best imaging instrument to evaluate IDD. The Pfirrmann classification is commonly used to grade IDD; the authors describing this classification showed an adequate agreement using it; however, there has been a paucity of independent agreement studies using this grading system. The aim of this study was to perform an independent inter- and intra-observer agreement study using the Pfirrmann classification. T2-weighted sagittal images of 79 patients consecutively studied with lumbar spine MRI were classified using the Pfirrmann grading system by six evaluators (three spine surgeons and three radiologists). After a 6-week interval, the 79 cases were presented to the same evaluators in a random sequence for repeat evaluation. The intra-class correlation coefficient (ICC) and the weighted kappa (wκ) were used to determine the inter- and intra-observer agreement. The inter-observer agreement was excellent, with an ICC = 0.94 (0.93-0.95) and wκ = 0.83 (0.74-0.91). There were no differences between spine surgeons and radiologists. Likewise, there were no differences in agreement evaluating the different lumbar discs. Most differences among observers were only of one grade. Intra-observer agreement was also excellent with ICC = 0.86 (0.83-0.89) and wκ = 0.89 (0.85-0.93). In this independent study, the Pfirrmann classification demonstrated an adequate agreement among different observers and by the same observer on separate occasions. Furthermore, it allows communication between radiologists and spine surgeons.
Munro, Aime; Williams, Vincent; Semmens, James; Leung, Yee; Stewart, Colin J R; Codde, Jim; Spilsbury, Katrina; Steel, Nerida; Cohen, Paul; O'leary, Peter
2015-06-01
In 2006, Australia adopted a revised cervical cytology terminology system, known as the Australian Modified Bethesda System (AMBS). One substantial change in the AMBS was the introduction of the diagnostic category of atypical endocervical cells (AEC) of undetermined significance. The aim of this study was to investigate the incidence of histologically confirmed high-grade cervical dysplasia (cervical intra-epithelial neoplasia (CIN) grades 2 and 3 and adenocarcinoma in situ (ACIS)), cervical carcinoma and endometrial carcinoma in women presenting with AEC on cervical cytology. A seven-year retrospective study examining clinical outcomes of women with AEC on a screening cervical smear. Cytology and histology results were extracted from the Western Australia Cervical Screening Registry, and time-to-event analysis was used to predict the odds of having or developing in situ and invasive neoplasia. AEC was reported in index smears from 0.093% (584/622754) women during the study period. No follow-up was available in 35 AEC cases. Sixty-five of the remaining 549 women (11.8%) had, or developed, high-grade cervical dysplasia within five years of their index AEC diagnosis. Endometrial cancer was diagnosed in 21 women and cervical cancer in four women during the follow-up period. Cytologic demonstration of AEC requires careful gynaecologic evaluation, particularly in younger women who may be found to have either high-grade squamous (CIN) or glandular (ACIS) lesions, while in older women, the possibility of endometrial neoplasia needs to be considered. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
ERIC Educational Resources Information Center
Kotoka, Jonas; Kriek, Jeanne
2014-01-01
The impact of computer simulations on the performance of 65 grade 11 learners in electromagnetism in a South African high school in the Mpumalanga province is investigated. Learners did not use the simulations individually, but teachers used them as an interactive demonstration tool. Basic concepts in electromagnetism are difficult to understand…
Low cost lab-on-a-chip prototyping with a consumer grade 3D printer.
Comina, Germán; Suska, Anke; Filippini, Daniel
2014-08-21
Versatile prototyping of 3D printed lab-on-a-chip devices, supporting different forms of sample delivery, transport, functionalization and readout, is demonstrated with a consumer grade printer, which centralizes all critical fabrication tasks. Devices cost 0.57US$ and are demonstrated in chemical sensing and micromixing examples, which exploit established principles from reference technologies.
Report on METHODS OF Evaluating Students at the University of California, Berkeley.
ERIC Educational Resources Information Center
Miller, Stuart
Several arguments are made for changing the present system of grading in college. The arguments deal with: (1) the negative effect of grading on the teaching situation--the system is capricious and variable and encourages "grade grubbing"; (2) the lack of accuracy and uniformity of grades; (3) the effect of grading, as an enforcer of the…
Tepeler, Abdulkadir; Resorlu, Berkan; Sahin, Tolga; Sarikaya, Selcuk; Bayindir, Mirze; Oguz, Ural; Armagan, Abdullah; Unsal, Ali
2014-02-01
To review our experience with ureteroscopy (URS) in the treatment of ureteral calculi and stratify intraoperative complications of URS according to the modified Satava classification system. We performed a retrospective analysis of 1,208 patients (672 males and 536 females), with a mean age of 43.1 years (range 1-78), who underwent ureteroscopic procedures for removal of ureteral stones. Intraoperative complications were recorded according to modified Satava classification system. Grade 1 complications included incidents without consequences for the patient; grade 2 complications, which are treated intraoperatively with endoscopic surgery (grade 2a) or required endoscopic re-treatment (grade 2b); and grade 3 complications included incidents requiring open or laparoscopic surgery. The stones were completely removed in 1,067 (88.3%) patients after primary procedure by either simple extraction or after fragmentation. The overall incidence of intraoperative complications was 12.6%. The most common complications were proximal stone migration (3.9%), mucosal injury (2.8%), bleeding (1.9%), inability to reach stone (1.8%), malfunctioning or breakage of instruments (0.8%), ureteral perforation (0.8%) and ureteral avulsion (0.16%). According to modified Satava classification system, there were 4.5% grade 1; 4.4% grade 2a; 3.2% grade 2b; and 0.57% grade 3 complications. We think that modified Satava classification is a quick and simple system for describing the severity of intraoperative URS complications and this grading system will facilitate a better comparison for the surgical outcomes obtained from different centers.
ERIC Educational Resources Information Center
Douglas, James Roy, II.
2016-01-01
Reading ability is one of the most crucial skills learned in elementary school, a primary focus for students in these years. Around the third grade, though, students start transitioning to a skill they will need the rest of their academic and work career--reading to learn. Students begin demonstrating their learning by taking high-stakes…
Omidvar, Mohsen; Mazloumi, Adel; Mohammad Fam, Iraj; Nirumand, Fereshteh
2017-01-01
Resilience engineering (RE) can be an alternative technique to the traditional risk assessment and management techniques, to predict and manage safety conditions of modern socio-technical organizations. While traditional risk management approaches are retrospective and highlight error calculation and computation of malfunction possibilities, resilience engineering seeks ways to improve capacity at all levels of organizations in order to build strong yet flexible processes. Considering the resilience potential measurement as a concern in complex working systems, the aim of this study was to quantify the resilience by the help of fuzzy sets and Multi-Criteria Decision-Making (MCDM) techniques. In this paper, we adopted the fuzzy analytic hierarchy process (FAHP) method to measure resilience in a gas refinery plant. A resilience assessment framework containing six indicators, each with its own sub-indicators, was constructed. Then, the fuzzy weights of the indicators and the sub-indicators were derived from pair-wise comparisons conducted by experts. The fuzzy evaluating vectors of the indicators and the sub-indicators computed according to the initial assessment data. Finally, the Comprehensive Resilience Index (CoRI), Resilience Grade (RG), and Resilience Early Warning Grade (REWG) were established. To demonstrate the applicability of the proposed method, an illustrative example in a gas refinery complex (an instance of socio-technical systems) was provided. CoRI of the refinery ranked as "III". In addition, for the six main indicators, RG and REWG ranked as "III" and "NEWZ", respectively, except for C3, in which RG ranked as "II", and REWG ranked as "OEWZ". The results revealed the engineering practicability and usefulness of the proposed method in resilience evaluation of socio-technical systems.
NASA Astrophysics Data System (ADS)
de Souza, Gabriel Fernandes; Tan, Lippong; Singh, Baljit; Ding, Lai Chet; Date, Abhijit
2017-04-01
The paper presents a sustainable hybrid system, which is capable of generating electricity and producing freshwater from seawater using low grade heat source. This proposed system uses low grade heat that can be supplied from solar radiation, industrial waste heat or any other waste heat sources where the temperature is less than 150°C. The concept behind this system uses the Seebeck effect for thermoelectricity generation via incorporating the low boiling point of seawater under sub-atmospheric ambient pressure. A lab-test prototype of the proposed system was built and experimentally tested in RMIT University. The prototype utilised four commercial available thermoelectric generators (Bi2Te3) and a vacuum vessel to achieve the simultaneous production of electricity and freshwater. The temperature profiles, thermoelectric powers and freshwater productions were determined at several levels of salinity to study the influence of different salt concentrations. The theoretical description of system design and experimental results were analysed and discussed in detailed. The experiment results showed that 0.75W of thermoelectricity and 404g of freshwater were produced using inputs of 150W of simulated waste heat and 500g of 3% saline water. The proposed hybrid concept has demonstrated the potential to become the future sustainable system for electricity and freshwater productions.
Smartphone-based grading of apple quality
NASA Astrophysics Data System (ADS)
Li, Xianglin; Li, Ting
2018-02-01
Apple quality grading is a critical issue in apple industry which is one economical pillar of many countries. Artificial grading is inefficient and of poor accuracy. Here we proposed to develop a portable, convenient, real-time, and low cost method aimed at grading apple. Color images of the apples were collected with a smartphone and the grade of sampled apple was assessed by a customized smartphone app, which offered the functions translating RGB color values of the apple to color grade and translating the edge of apple image to weight grade. The algorithms are based on modeling with a large number of apple image at different grades. The apple grade data evaluated by the smartphone are in accordance with the actual data. This study demonstrated the potential of smart phone in apple quality grading/online monitoring at gathering and transportation stage for apple industry.
NASA Astrophysics Data System (ADS)
Zhang, Yanjiao; Lai, Xiaoping; Zeng, Qiuyao; Li, Linfang; Lin, Lin; Li, Shaoxin; Liu, Zhiming; Su, Chengkang; Qi, Minni; Guo, Zhouyi
2018-03-01
This study aims to classify low-grade and high-grade bladder cancer (BC) patients using serum surface-enhanced Raman scattering (SERS) spectra and support vector machine (SVM) algorithms. Serum SERS spectra are acquired from 88 serum samples with silver nanoparticles as the SERS-active substrate. Diagnostic accuracies of 96.4% and 95.4% are obtained when differentiating the serum SERS spectra of all BC patients versus normal subjects and low-grade versus high-grade BC patients, respectively, with optimal SVM classifier models. This study demonstrates that the serum SERS technique combined with SVM has great potential to noninvasively detect and classify high-grade and low-grade BC patients.
Patel, Neha A; Carlin, Kristen; Bernstein, Joseph M
Current grading systems may not allow clinicians to reliably document and communicate adenotonsillar size in the clinical setting. A validated endoscopic grading system may be useful for reporting tonsillar size in future clinical outcome studies. This is especially important as tonsillar enlargement is the cause of a substantial health care burden on children. To propose and validate an easy-to-use flexible fiberoptic endoscopic grading system that provides physicians with a more accurate sense of the three-dimensional relationship of the tonsillar fossa to the upper-airway. 50 consecutive pediatric patients were prospectively recruited between February 2015 and February 2016 at a pediatric otolaryngology outpatient clinic. The patients had no major craniofacial abnormalities and were aged 1 to 16years. Each patient had data regarding BMI, Friedman palate position, OSA-18 survey results collected. For each child, digital video clips of fiberoptic nasopharyngeal, oropharyngeal and laryngeal exams were presented to 2 examiners. Examiners were asked to independently use the proposed Endoscopic tonsillar grading system, the Brodsky tonsillar grading scale, the Modified Brodsky tonsillar grading scale with a tongue depressor, and the Parikh adenoid grading system to rate adenotonsillar hypertrophy. Cohen's Kappa and weighted Kappa scores were used to assess interrater reliability for each of the four grading scales. The Spearman correlation was used to test the associations between each scale and OSA-18 scores, as well as Body Mass Index (BMI). 50 pediatric patients were included in this study (mean age 6.1years, range of 1year to 16years). The average BMI was 20. The average OSA-18 score was 61.7. The average Friedman palate position score was 1.34. Twelve percent of the patients had a Friedman palate position score≥3, which made traditional Brodsky grading of their tonsils impossible without a tongue depressor. All four scales showed strong agreement between the two raters. The weighted Kappa was 0.83 for the Modified Brodsky scale, 0.89 for the Brodsky scale, 0.94 for the Parikh scale to 0.98 for the Endoscopic scale (almost perfect agreement). The Endoscopic scale showed the most consistent agreement between the raters during the study. There was a moderate association between the Parikh adenoid grading system with OSA-18 scores (Spearman's ρ=0.58, p<0.001) compared to a low association of the tonsillar grading systems with OSA- 18 scores. None of the scales correlated with patient BMI. The proposed Endoscopic tonsillar grading system is as reliable of a method of grading tonsillar size as conventional grading systems. It offers the advantage of allowing for critical evaluation of the tonsils without any anatomic distortion which may occur with the use of a tongue blade. This new validated endoscopic grading system provides a tool for communicating the degree of airway obstruction at the level of the oropharynx regardless of Friedman palate position and may be used in future outcomes projects. Copyright © 2017 Elsevier Inc. All rights reserved.
Damage tolerant functionally graded materials for advanced wear and friction applications
NASA Astrophysics Data System (ADS)
Prchlik, Lubos
The research work presented in this dissertation focused on processing effects, microstructure development, characterization and performance evaluation of composite and graded coatings used for friction and wear control. The following issues were addressed. (1) Definition of prerequisites for a successful composite and graded coating formation by means of thermal spraying. (2) Improvement of characterization methods available for homogenous thermally sprayed coating and their extension to composite and graded materials. (3) Development of novel characterization methods specifically for FGMs, with a focus on through thickness property measurement by indentation and in-situ curvature techniques. (4) Design of composite materials with improved properties compared to homogenous coatings. (5) Fabrication and performance assessment of FGM with improved wear and impact damage properties. Materials. The materials studied included several material systems relevant to low friction and contact damage tolerant applications: MO-Mo2C, WC-Co cermets as materials commonly used sliding components of industrial machinery and NiCrAlY/8%-Yttria Partially Stabilized Zirconia composites as a potential solution for abradable sections of gas turbines and aircraft engines. In addition, uniform coatings such as molybdenum and Ni5%Al alloy were evaluated as model system to assess the influence of microstructure variation onto the mechanical property and wear response. Methods. The contact response of the materials was investigated through several techniques. These included methods evaluating the relevant intrinsic coating properties such as elastic modulus, residual stress, fracture toughness, scratch resistance and tests measuring the abrasion and friction-sliding behavior. Dry-sand and wet two-body abrasion testing was performed in addition to traditional ball on disc sliding tests. Among all characterization techniques the spherical indentation deserved most attention and enabled to measure elastic-plastic properties of uniform and graded structures. In-situ curvature method used for residual stress and elastic modulus measurement was extended from uniform coatings to coatings with compositional/property gradients. Properties of composite and graded materials were measured using the inverse analysis. Conclusions. The specifics of the elastic-plastic response for thermally sprayed coatings were demonstrated. These included the strain dependence of elastic modulus and damage accumulation related to unloading/reloading loop formation. The measurement of elastic-plastic characteristics of composite coatings revealed the mixing and bonding mechanisms unique for thermally sprayed materials. Microstructural and compositional factors governing the frictional vs. abrasion response of carbide-metallic composite coatings were described. The measurement of abrasion resistance and friction sliding properties demonstrated that grading of cermet and ceramic coatings by adding moderate amount of metallic alloys can enhance elastic-properties radically and have a beneficial effect onto the coating performance.
MORPHOLOGICAL PATTERN AND FREQUENCY OF CENTRAL NERVOUS SYSTEM TUMOURS IN CHILDREN.
Bilqees, Fatima; Samina, Khaleeq; Mohammad, Tahir; Khaleeq-uz-Zamaan
2016-01-01
Recent studies, including a comprehensive study by National Cancer Institute, have shown that a significant increase in the incidence of childhood brain tumours makes them the most common paediatric tumour. The objectives of this study were to determine the frequency of central nervous system tumours in paediatric age group (0-12 years), and to segregate various morphologic types according to WHO classification. The study included consecutive cases of central nervous system tumours diagnosed in children in the histopathology department at Federal Government Polyclinic, PGMI, Islamabad, during a period of 4.8 years (Jan 2009-Aug 2013). The initial histopathological evaluation of these lesions was performed on H&E stained sections of paraffin embedded tissues. Special stains and immunohistochemistry were performed whenever indicated. Out of 75 cases, 34 (45.3%) were astrocytic tumours, including 16 (47.1%) Pilocytic astrocytomas (WHO Grade-I), 1 (2.9%) diffuse fibrillary astrocytoma (WHO Grade-II), 1 (2.9%) anaplastic astrocytoma (WHO Grade-III) and 16(47.1%) glioblastoma multiforme (WHO Grade-IV); 18 (24%) were embryonal tumours including 17 (94.4%) medulloblastoma (WHO Grade-IV) and 1 (5.6%) neuroblastoma (WHO Grade IV); 10 (13.3%) were craniopharyngiomas (WHO Grade-I) and 5 (6.7%) were ependymal tumours including 1 (20%) myxopapillary ependymoma (WHO Grade-I) and 4 (80%) ependymomas (WHO Grade-II). Miscellaneous entities included 3 (4%) choroid plexus tumours; 1 (2%) anaplastic oligodendroglioma (WHO Grade-III); 1 (2%) atypical meningioma (WHO Grade-II); 1 (2%) schwannoma (WHO Grade-I); 1 (2%) neurofibroma (WHO Grade-I) and 1 (2%) lipoma (WHO Grade-I). Astrocytic tumours are the most common central nervous system tumours in paediatric age group and high grade lesions (WHO Grade-IV) constitute the largest category (45.3%).
NASA Astrophysics Data System (ADS)
Nasir, Ahmad Fakhri Ab; Suhaila Sabarudin, Siti; Majeed, Anwar P. P. Abdul; Ghani, Ahmad Shahrizan Abdul
2018-04-01
Chicken egg is a source of food of high demand by humans. Human operators cannot work perfectly and continuously when conducting egg grading. Instead of an egg grading system using weight measure, an automatic system for egg grading using computer vision (using egg shape parameter) can be used to improve the productivity of egg grading. However, early hypothesis has indicated that more number of egg classes will change when using egg shape parameter compared with using weight measure. This paper presents the comparison of egg classification by the two above-mentioned methods. Firstly, 120 images of chicken eggs of various grades (A–D) produced in Malaysia are captured. Then, the egg images are processed using image pre-processing techniques, such as image cropping, smoothing and segmentation. Thereafter, eight egg shape features, including area, major axis length, minor axis length, volume, diameter and perimeter, are extracted. Lastly, feature selection (information gain ratio) and feature extraction (principal component analysis) are performed using k-nearest neighbour classifier in the classification process. Two methods, namely, supervised learning (using weight measure as graded by egg supplier) and unsupervised learning (using egg shape parameters as graded by ourselves), are conducted to execute the experiment. Clustering results reveal many changes in egg classes after performing shape-based grading. On average, the best recognition results using shape-based grading label is 94.16% while using weight-based label is 44.17%. As conclusion, automated egg grading system using computer vision is better by implementing shape-based features since it uses image meanwhile the weight parameter is more suitable by using weight grading system.
Zhang, Ming-hui; Liu, Yan-hui; Luo, Xin-lan; Lin, Xing-tao; Zhuang, Heng-guo
2012-07-01
To study the clinicopathologic and prognostic features of neuroendocrine neoplasm of digestive system with different grades. The clinicopathologic features of 139 cases of neuroendocrine neoplasm occurring in digestive system were retrospectively reviewed and graded according to the 2010 World Health Organization classification of tumours of the digestive system. Immunohistochemical study for synaptophysin, chromogranin A and Ki-67 was carried out. The follow-up and survival data were analysed using Kaplan-Meier method. Prognostic factors were tested by Log-rank testing and independent risk factors were analysed using Cox regression model. Amongst the 139 cases studied, there were 88 cases (63.3%) of grade 1 tumors, 9 cases (6.5%) of grade 2 tumors and 42 cases (30.2%) of grade 3 tumors. There was diffusely positive staining for synaptophysin and chromogranin A in most of the grade 1 and grade 2 tumors. The staining in grade 3 tumors however was focal (P < 0.05). The differences in tumor size, depth of invasion, presence of tumor emboli, perineural permeation, nodal involvement, distant metastasis and survival rate amongst the three groups was statistically significant (P < 0.05). There is significant difference in the clinicopathologic and prognostic features of neuroendocrine neoplasm of digestive system with different grades. It is considered as an independent prognostic factor and represents a useful tool for prognostic evaluation of such tumors, both in clinical practice and research.
Diagnostic accuracy of pre-treatment biopsy for grading cutaneous mast cell tumours in dogs.
Shaw, T; Kudnig, S T; Firestone, S M
2018-06-01
Mast cell tumours (MCTs) are common tumours of the canine skin, and are estimated to represent up to 20% of all skin tumours in dogs. Tumour grade has a major impact on the incidence of local recurrence and metastatic potential. In addition to helping the clinician with surgical planning, knowledge of the tumour grade also assists in proper prognostication and client education. For pre-treatment biopsies to be useful, there must exist a high level of correlation between the histopathological grade obtained from the pre-treatment biopsy and the actual histopathological grade from the excisional biopsy. The aim of this study was to determine concordance of tumour grade between various biopsy techniques (wedge, punch, needle core) and the "gold standard" excisional biopsy method. We found an overall concordance rate of 96% based on the Patnaik grading system, and an overall concordance rate of 92% based on the Kiupel grading system. The accuracy of the various biopsy techniques (wedge, punch and needle core) when compared with excisional biopsy was 92%, 100% and 100%, respectively, based on the Patnaik grading system, and 90%, 95% and 100%, respectively, based on the Kiupel grading system. Of the cases with discordant results, the pre-treatment biopsies tended to underestimate the grade of the tumour. Based on these results, we conclude that pre-treatment biopsies are sufficiently accurate for differentiating low-grade from high-grade MCTs, regardless of biopsy technique or tumour location. © 2017 John Wiley & Sons Ltd.
Student and Faculty Perceptions of Plus/Minus Grading and Its Effect on Course Grade Point Averages
ERIC Educational Resources Information Center
Edgar, Leslie D.; Johnson, Donald M.; Graham, Donna L.; Dixon, Bruce L.
2014-01-01
In fall 2005, the Dale Bumpers College of Agricultural, Food and Life Sciences at the University of Arkansas authorized the optional use of a plus/minus grading system. Since 2005, approximately one-half of courses have been graded using plus/minus and one-half using the straight letter grade system. This study examined student (n = 338) and…
Khan, Faisal Aziz; Niazi, Shafaq Pervez Khan; Khan, Assad Zaman
2017-09-01
To determine the relationship of the van Herick angle grading system with the level of iris insertion and peripheral iris configuration. Observational study. Eye department, Combined Military Hospital, Malir Cantt., Karachi, from May to October 2015. Sixty-five eyes of 65 patients were recruited. Anterior chamber depth at the temporal limbus was measured as a fraction of corneal section thickness using van Herick technique and graded on the standard 4-point scale of the van Herick grading system. Gonioscopy of the temporal quadrant was performed with a Posner 4 mirror goniolens and both the true level of iris insertion and peripheral iris configuration were recorded on a 4-point scale so as to equate with the van Herick 4-point grading system. Spearman's rho test was applied to determine the relationship of the van Herick grading system with level of iris root insertion and peripheral iris configuration. Amoderate positive correlation between van Herick grade and peripheral iris configuration was found which was statistically significant (rs=0.42, p < 0.001). Astatistically significant and moderate positive correlation was also detected between van Herick grade and the level of iris insertion (rs=0.45, p < 0.001). The van Herick grade has a moderately positive relationship with the peripheral iris configuration and true level of iris insertion.
NASA Astrophysics Data System (ADS)
Putlitz, Benita; Valley, John; Matthews, Alan; Katzir, Yaron
2002-04-01
Diffusion models predict that peak metamorphic temperatures are best recorded by the oxygen isotope fractionation between minerals in a bi-mineralic rock in which a refractory accessory mineral with slow oxygen diffusion rate is modally minor to a mineral with a faster diffusion rate. This premise is demonstrated for high-grade metamorphism on the island of Naxos, Greece, where quartz-kyanite oxygen isotope thermometry from veins in high-grade metamorphic pelites gives temperatures of 635-690 °C. These temperatures are in excellent agreement with independent thermometry for the regional M2 peak metamorphic conditions and show that the vein minerals isotopically equilibrated at the peak of metamorphism. Quartz-sillimanite fractionations in the same veins give similar temperatures (680+/-35 °C) and suggest that the veins grew near to the kyanite-sillimanite boundary, corresponding to pressures of 6.5 to 7.5 kbar for temperatures of 635-685 °C. By contrast, quartz-kyanite and quartz-biotite pairs in the host rocks yield lower temperature estimates than the veins (590-600 and 350-550 °C, respectively). These lower apparent temperatures are also predicted from calculations of diffusional resetting in the polyphase host-rock system. The data demonstrate that bimineralic vein assemblages can be used as accurate thermometers in high-temperature rocks whereas retrograde exchange remains a major problem in many polymineralic rocks.
A Pulsed Thermographic Imaging System for Detection and Identification of Cotton Foreign Matter
Kuzy, Jesse; Li, Changying
2017-01-01
Detection of foreign matter in cleaned cotton is instrumental to accurately grading cotton quality, which in turn impacts the marketability of the cotton. Current grading systems return estimates of the amount of foreign matter present, but provide no information about the identity of the contaminants. This paper explores the use of pulsed thermographic analysis to detect and identify cotton foreign matter. The design and implementation of a pulsed thermographic analysis system is described. A sample set of 240 foreign matter and cotton lint samples were collected. Hand-crafted waveform features and frequency-domain features were extracted and analyzed for statistical significance. Classification was performed on these features using linear discriminant analysis and support vector machines. Using waveform features and support vector machine classifiers, detection of cotton foreign matter was performed with 99.17% accuracy. Using frequency-domain features and linear discriminant analysis, identification was performed with 90.00% accuracy. These results demonstrate that pulsed thermographic imaging analysis produces data which is of significant utility for the detection and identification of cotton foreign matter. PMID:28273848
Epstein, Jonathan I; Egevad, Lars; Amin, Mahul B; Delahunt, Brett; Srigley, John R; Humphrey, Peter A
2016-02-01
In November, 2014, 65 prostate cancer pathology experts, along with 17 clinicians including urologists, radiation oncologists, and medical oncologists from 19 different countries gathered in a consensus conference to update the grading of prostate cancer, last revised in 2005. The major conclusions were: (1) Cribriform glands should be assigned a Gleason pattern 4, regardless of morphology; (2) Glomeruloid glands should be assigned a Gleason pattern 4, regardless of morphology; (3) Grading of mucinous carcinoma of the prostate should be based on its underlying growth pattern rather than grading them all as pattern 4; and (4) Intraductal carcinoma of the prostate without invasive carcinoma should not be assigned a Gleason grade and a comment as to its invariable association with aggressive prostate cancer should be made. Regarding morphologies of Gleason patterns, there was clear consensus on: (1) Gleason pattern 4 includes cribriform, fused, and poorly formed glands; (2) The term hypernephromatoid cancer should not be used; (3) For a diagnosis of Gleason pattern 4, it needs to be seen at 10x lens magnification; (4) Occasional/seemingly poorly formed or fused glands between well-formed glands is insufficient for a diagnosis of pattern 4; (5) In cases with borderline morphology between Gleason pattern 3 and pattern 4 and crush artifacts, the lower grade should be favored; (6) Branched glands are allowed in Gleason pattern 3; (7) Small solid cylinders represent Gleason pattern 5; (8) Solid medium to large nests with rosette-like spaces should be considered to represent Gleason pattern 5; and (9) Presence of unequivocal comedonecrosis, even if focal is indicative of Gleason pattern 5. It was recognized by both pathologists and clinicians that despite the above changes, there were deficiencies with the Gleason system. The Gleason grading system ranges from 2 to 10, yet 6 is the lowest score currently assigned. When patients are told that they have a Gleason score 6 out of 10, it implies that their prognosis is intermediate and contributes to their fear of having a more aggressive cancer. Also, in the literature and for therapeutic purposes, various scores have been incorrectly grouped together with the assumption that they have a similar prognosis. For example, many classification systems consider Gleason score 7 as a single score without distinguishing 3+4 versus 4+3, despite studies showing significantly worse prognosis for the latter. The basis for a new grading system was proposed in 2013 by one of the authors (J.I.E.) based on data from Johns Hopkins Hospital resulting in 5 prognostically distinct Grade Groups. This new system was validated in a multi-institutional study of over 20,000 radical prostatectomy specimens, over 16,000 needle biopsy specimens, and over 5,000 biopsies followed by radiation therapy. There was broad (90%) consensus for the adoption of this new prostate cancer Grading system in the 2014 consensus conference based on: (1) the new classification provided more accurate stratification of tumors than the current system; (2) the classification simplified the number of grading categories from Gleason scores 2 to 10, with even more permutations based on different pattern combinations, to Grade Groups 1 to 5; (3) the lowest grade is 1 not 6 as in Gleason, with the potential to reduce overtreatment of indolent cancer; and (4) the current modified Gleason grading, which forms the basis for the new grade groups, bears little resemblance to the original Gleason system. The new grades would, for the foreseeable future, be used in conjunction with the Gleason system [ie. Gleason score 3+3=6 (Grade Group 1)]. The new grading system and the terminology Grade Groups 1-5 have also been accepted by the World Health Organization for the 2016 edition of Pathology and Genetics: Tumours of the Urinary System and Male Genital Organs.
van de Putte, Elisabeth E Fransen; Bosschieter, Judith; van der Kwast, Theo H; Bertz, Simone; Denzinger, Stefan; Manach, Quentin; Compérat, Eva M; Boormans, Joost L; Jewett, Michael A S; Stoehr, Robert; van Leenders, Geert J L H; Nieuwenhuijzen, Jakko A; Zlotta, Alexandre R; Hendricksen, Kees; Rouprêt, Morgan; Otto, Wolfgang; Burger, Maximilian; Hartmann, Arndt; van Rhijn, Bas W G
2018-04-10
To compare the prognostic value of the World Health Organization (WHO) 1973 and 2004 classification systems for grade in T1 bladder cancer (T1-BC), as both are currently recommended in international guidelines. Three uro-pathologists re-revised slides of 601 primary (first diagnosis) T1-BCs, initially managed conservatively (bacille Calmette-Guérin) in four hospitals. Grade was defined according to WHO1973 (Grade 1-3) and WHO2004 (low-grade [LG] and high-grade [HG]). This resulted in a lack of Grade 1 tumours, 188 (31%) Grade 2, and 413 (69%) Grade 3 tumours. There were 47 LG (8%) vs 554 (92%) HG tumours. We determined the prognostic value for progression-free survival (PFS) and cancer-specific survival (CSS) in Cox-regression models and corrected for age, sex, multiplicity, size and concomitant carcinoma in situ. At a median follow-up of 5.9 years, 148 patients showed progression and 94 died from BC. The WHO1973 Grade 3 was negatively associated with PFS (hazard ratio [HR] 2.1) and CSS (HR 3.4), whilst WHO2004 grade was not prognostic. On multivariable analysis, WHO1973 grade was the only prognostic factor for progression (HR 2.0). Grade 3 tumours (HR 3.0), older age (HR 1.03) and tumour size >3 cm (HR 1.8) were all independently associated with worse CSS. The WHO1973 classification system for grade has strong prognostic value in T1-BC, compared to the WHO2004 system. Our present results suggest that WHO1973 grade cannot be replaced by the WHO2004 classification in non-muscle-invasive BC guidelines. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.
Cranial Chordoma: A New Preoperative Grading System.
Brito da Silva, Harley; Straus, David; Barber, Jason K; Rostomily, Robert C; Ferreira, Manuel; Sekhar, Laligam N
2017-11-03
Chordomas are rare but challenging neoplasms involving the skull base. A preoperative grading system will be useful to identify both areas for treatment and risk factors, and correlate to the degree of resection, complications, and recurrence. To propose a new grading system for cranial chordomas designed by the senior author. Its purpose is to enable comparison of different tumors with a similar pathology to clivus chordoma, and statistically correlate with postoperative outcomes. The numerical grading system included tumor size, site of the tumor, vascular encasement, intradural extension, brainstem invasion, and recurrence of the tumor either after surgery or radiotherapy with a range of 2 to 25 points; it was used in 42 patients with cranial chordoma. The grading system was correlated with number of operations for resection, degree of resection, number and type of complications, recurrence, and survival. We found 3 groups: low-risk 0 to 7 points, intermediate-risk 8 to 12 points, and high-risk ≥13 points in the grading system. The 3 groups were correlated with the following: extent of resection (partial, subtotal, or complete; P < .002); number of operative stages to achieve removal (P < .014); tumor recurrence (P = .03); postoperative Karnofsky Performance Status (P < .001); and with successful outcome (P = .005). The grading system itself correlated with the outcome (P = .005). The proposed chordoma grading system can help surgeons to predict the difficulty of the case and know which areas of the skull base will need attention to plan further therapy. © Congress of Neurological Surgeons 2017.
Neuropathic pain: an updated grading system for research and clinical practice.
Finnerup, Nanna B; Haroutounian, Simon; Kamerman, Peter; Baron, Ralf; Bennett, David L H; Bouhassira, Didier; Cruccu, Giorgio; Freeman, Roy; Hansson, Per; Nurmikko, Turo; Raja, Srinivasa N; Rice, Andrew S C; Serra, Jordi; Smith, Blair H; Treede, Rolf-Detlef; Jensen, Troels S
2016-08-01
The redefinition of neuropathic pain as "pain arising as a direct consequence of a lesion or disease affecting the somatosensory system," which was suggested by the International Association for the Study of Pain (IASP) Special Interest Group on Neuropathic Pain (NeuPSIG) in 2008, has been widely accepted. In contrast, the proposed grading system of possible, probable, and definite neuropathic pain from 2008 has been used to a lesser extent. Here, we report a citation analysis of the original NeuPSIG grading paper of 2008, followed by an analysis of its use by an expert panel and recommendations for an improved grading system. As of February, 2015, 608 eligible articles in Scopus cited the paper, 414 of which cited the neuropathic pain definition. Of 220 clinical studies citing the paper, 56 had used the grading system. The percentage using the grading system increased from 5% in 2009 to 30% in 2014. Obstacles to a wider use of the grading system were identified, including (1) questions about the relative significance of confirmatory tests, (2) the role of screening tools, and (3) uncertainties about what is considered a neuroanatomically plausible pain distribution. Here, we present a revised grading system with an adjusted order, better reflecting clinical practice, improvements in the specifications, and a word of caution that even the "definite" level of neuropathic pain does not always indicate causality. In addition, we add a table illustrating the area of pain and sensory abnormalities in common neuropathic pain conditions and propose areas for further research.
End-of-Grade (EOG) Multiple-Choice Test Results, 2008-09. Measuring Up. E&R Report No. 10.12
ERIC Educational Resources Information Center
McMillen, Brad
2010-01-01
In 2008-09, results from End-of-Grade (EOG) reading and mathematics tests in WCPSS continued to demonstrate an upward trend across grade levels and student subgroups. Disaggregation of results by ethnicity, income level, disability status, and English proficiency status showed that achievement gaps between historically underperforming subgroups…
Grade-Level Declines in Perceived Academic Support from Peers: A Moderated Mediation Analysis
ERIC Educational Resources Information Center
Altermatt, Ellen Rydell
2017-01-01
Prior research demonstrates that perceived academic support from peers positively predicts school adjustment. In this cross-sectional study, we provide evidence that perceived academic support from peers declines from 3rd to 8th grade and that this decline is partially mediated by grade-level declines in perceptions that academic success…
Cigarette Use in 6th Through 10th Grade: The Sarasota County Demonstration Project
ERIC Educational Resources Information Center
Zapata, Lauren B.; Forthofer, Melinda S.; Eaton, Danice K.; Brown, Kelli McCormack; Bryant, Carol A.; Reynolds, Sherri T.; McDermot, Robert J.
2004-01-01
Objectives: To identify factors associated with cigarette smoking in the 6 th -grade through 10 th -grade youth population of Sarasota County, Florida. Methods: A closed-ended, quantitative survey was completed by 2004 youth and used to extract population-specific data on the correlates of cigarette use. Results: A range of factors influence…
A Virtual Reality Visualization Tool for Neuron Tracing
Usher, Will; Klacansky, Pavol; Federer, Frederick; Bremer, Peer-Timo; Knoll, Aaron; Angelucci, Alessandra; Pascucci, Valerio
2017-01-01
Tracing neurons in large-scale microscopy data is crucial to establishing a wiring diagram of the brain, which is needed to understand how neural circuits in the brain process information and generate behavior. Automatic techniques often fail for large and complex datasets, and connectomics researchers may spend weeks or months manually tracing neurons using 2D image stacks. We present a design study of a new virtual reality (VR) system, developed in collaboration with trained neuroanatomists, to trace neurons in microscope scans of the visual cortex of primates. We hypothesize that using consumer-grade VR technology to interact with neurons directly in 3D will help neuroscientists better resolve complex cases and enable them to trace neurons faster and with less physical and mental strain. We discuss both the design process and technical challenges in developing an interactive system to navigate and manipulate terabyte-sized image volumes in VR. Using a number of different datasets, we demonstrate that, compared to widely used commercial software, consumer-grade VR presents a promising alternative for scientists. PMID:28866520
NASA Astrophysics Data System (ADS)
Wu, Tao; Cheung, Tak-Hong; Yim, So-Fan; Qu, Jianan Y.
2010-03-01
A quantitative colposcopic imaging system for the diagnosis of early cervical cancer is evaluated in a clinical study. This imaging technology based on 3-D active stereo vision and motion tracking extracts diagnostic information from the kinetics of acetowhitening process measured from the cervix of human subjects in vivo. Acetowhitening kinetics measured from 137 cervical sites of 57 subjects are analyzed and classified using multivariate statistical algorithms. Cross-validation methods are used to evaluate the performance of the diagnostic algorithms. The results show that an algorithm for screening precancer produced 95% sensitivity (SE) and 96% specificity (SP) for discriminating normal and human papillomavirus (HPV)-infected tissues from cervical intraepithelial neoplasia (CIN) lesions. For a diagnostic algorithm, 91% SE and 90% SP are achieved for discriminating normal tissue, HPV infected tissue, and low-grade CIN lesions from high-grade CIN lesions. The results demonstrate that the quantitative colposcopic imaging system could provide objective screening and diagnostic information for early detection of cervical cancer.
A Virtual Reality Visualization Tool for Neuron Tracing.
Usher, Will; Klacansky, Pavol; Federer, Frederick; Bremer, Peer-Timo; Knoll, Aaron; Yarch, Jeff; Angelucci, Alessandra; Pascucci, Valerio
2018-01-01
Tracing neurons in large-scale microscopy data is crucial to establishing a wiring diagram of the brain, which is needed to understand how neural circuits in the brain process information and generate behavior. Automatic techniques often fail for large and complex datasets, and connectomics researchers may spend weeks or months manually tracing neurons using 2D image stacks. We present a design study of a new virtual reality (VR) system, developed in collaboration with trained neuroanatomists, to trace neurons in microscope scans of the visual cortex of primates. We hypothesize that using consumer-grade VR technology to interact with neurons directly in 3D will help neuroscientists better resolve complex cases and enable them to trace neurons faster and with less physical and mental strain. We discuss both the design process and technical challenges in developing an interactive system to navigate and manipulate terabyte-sized image volumes in VR. Using a number of different datasets, we demonstrate that, compared to widely used commercial software, consumer-grade VR presents a promising alternative for scientists.
Grading Practices and Distributions Across Internal Medicine Clerkships.
Fazio, Sara B; Torre, Dario M; DeFer, Thomas M
2016-01-01
Clerkship evaluation and grading practices vary widely between U.S. medical schools. Grade inflation continues to exist, and grade distribution is likely to be different among U.S. medical schools. Increasing the number of available grades curtails "grade inflation." A national survey of all Clerkship Directors in Internal Medicine members was administered in 2011. The authors assessed key aspects of grading. Response rate was 76%. Among clerkship directors (CDs), 61% of respondents agreed that grade inflation existed in the internal medicine clerkship at their school, and 43% believed that it helped students obtain better residency positions. With respect to grading practices, 79% of CDs define specific behaviors needed to achieve each grade, and 36% specify an ideal grade distribution. In addition, 44% have a trained core faculty responsible for evaluating students, 35% describe formal grading meetings, and 39% use the Reporter-Interpreter-Manager-Educator (RIME) scheme. Grading scales were described as follows: 4% utilize a pass/fail system, 13% a 3-tier (e.g., Honors/Pass/Fail), 45% 4-tier, 35% 5-tier, and 4% 6+-tier system. There was a trend to higher grades with more tiers available. Grade inflation continues in the internal medicine clerkship. Almost half of CDs feel that this practice assists students to obtain better residency positions. A minority of programs have a trained core faculty who are responsible for evaluation. About one third have formal grading meetings and use the RIME system; both have been associated with more robust and balanced grading practices. In particular, there is a wide variation between schools in the percentage of students who are awarded the highest grade, which has implications for residency applications. Downstream users of clinical clerkship grades must be fully aware of these variations in grading in order to appropriately judge medical student performance.
GMP-grade human fetal liver-derived mesenchymal stem cells for clinical transplantation.
Larijani, Bagher; Aghayan, Hamid-Reza; Goodarzi, Parisa; Arjmand, Babak
2015-01-01
Stem cell therapy seems a promising avenue in regenerative medicine. Within various stem cells, mesenchymal stem cells have progressively used for cellular therapy. Because of the age-related decreasing in the frequency and differentiating capacity of adult MSCs, fetal tissues such as fetal liver, lung, pancreas, spleen, etc. have been introduced as an alternative source of MSCs for cellular therapy. On the other hand, using stem cells as advanced therapy medicinal products, must be performed in compliance with cGMP as a quality assurance system to ensure the safety, quality, and identity of cell products during translation from the basic stem cell sciences into clinical cell transplantation. In this chapter the authors have demonstrated the manufacturing of GMP-grade human fetal liver-derived mesenchymal stem cells.
Ma, Lin; Hanzawa, Nobutomo; Tsujikawa, Kyozo; Azuma, Yuji
2012-10-22
We demonstrated ultra-wideband wavelength division multiplexing (WDM) transmission from 850 to 1550 nm in graded-index multi-mode fiber (GI-MMF) using endlessly single-mode photonic crystal fiber (ESM-PCF) as a launch device. Effective single-mode guidance is obtained in multi-mode fiber at all wavelengths by splicing cm-order length ESM-PCF to the transmission fiber. We achieved 3 × 10 Gbit/s WDM transmission in a 1 km-long 50-μm-core GI-MMF. We also realized penalty free 10 Gbit/s data transmission at a wavelength of 850 nm by optimizing the PCF structure. This method has the potential to achieve greater total transmission capacity for MMF systems by the addition of more wavelength channels.
Shackelford, S D; Wheeler, T L; Koohmaraie, M
2003-01-01
The present experiment was conducted to evaluate the ability of the U.S. Meat Animal Research Center's beef carcass image analysis system to predict calculated yield grade, longissimus muscle area, preliminary yield grade, adjusted preliminary yield grade, and marbling score under commercial beef processing conditions. In two commercial beef-processing facilities, image analysis was conducted on 800 carcasses on the beef-grading chain immediately after the conventional USDA beef quality and yield grades were applied. Carcasses were blocked by plant and observed calculated yield grade. The carcasses were then separated, with 400 carcasses assigned to a calibration data set that was used to develop regression equations, and the remaining 400 carcasses assigned to a prediction data set used to validate the regression equations. Prediction equations, which included image analysis variables and hot carcass weight, accounted for 90, 88, 90, 88, and 76% of the variation in calculated yield grade, longissimus muscle area, preliminary yield grade, adjusted preliminary yield grade, and marbling score, respectively, in the prediction data set. In comparison, the official USDA yield grade as applied by online graders accounted for 73% of the variation in calculated yield grade. The technology described herein could be used by the beef industry to more accurately determine beef yield grades; however, this system does not provide an accurate enough prediction of marbling score to be used without USDA grader interaction for USDA quality grading.
Li, Ying; Shuang Liu, Zhong; Ming Bai, Xiao; Zhang, Bin
2013-01-01
Objective: To investigate the effects of graded models on the biomechanical behavior of a bone-implant system under osteoporotic conditions. Methodology : A finite element model (FEM) of the jawbone segments with a titanium implant is used. Two types of models (a graded model and a non-graded model) are established. The graded model is established based on the graded variation of the elastic modulus of the cortical bone and the non-graded model is defined by homogeneous cortical bone. The vertical and oblique loads are adopted. The max von Mises stresses and the max displacements of the cortical bone are evaluated. Results: Comparing the two types of models, the difference in the maximum von Mises stresses of the cortical bone is more than 20%. The values of the maximum displacements in the graded models are considerably less than in the non-graded models. Conclusions: These results indicate the significance of taking into account the actual graded properties of the cortical bone so that the biomechanical behavior of the bone-implant system can be analyzed accurately. PMID:24353590
Li, Ying; Shuang Liu, Zhong; Ming Bai, Xiao; Zhang, Bin
2013-04-01
To investigate the effects of graded models on the biomechanical behavior of a bone-implant system under osteoporotic conditions. Methodology : A finite element model (FEM) of the jawbone segments with a titanium implant is used. Two types of models (a graded model and a non-graded model) are established. The graded model is established based on the graded variation of the elastic modulus of the cortical bone and the non-graded model is defined by homogeneous cortical bone. The vertical and oblique loads are adopted. The max von Mises stresses and the max displacements of the cortical bone are evaluated. Comparing the two types of models, the difference in the maximum von Mises stresses of the cortical bone is more than 20%. The values of the maximum displacements in the graded models are considerably less than in the non-graded models. These results indicate the significance of taking into account the actual graded properties of the cortical bone so that the biomechanical behavior of the bone-implant system can be analyzed accurately.
The Effects of Framing Grades on Student Learning and Preferences
ERIC Educational Resources Information Center
Bies-Hernandez, Nicole J.
2012-01-01
Two experiments examined whether framing effects, in terms of losses and gains, can be extended to student learning and grading preferences. In Experiment 1, participants rated psychology course syllabi to investigate preferences for differently framed grading systems: a loss versus gain grading system. The results showed a clear framing effect…
Ye, Guang-Yao; Yu, Min-Hao; Gao, Yun-He; Li, Zhao-Shen; Yu, En-Da; Zhong, Ming
2013-01-01
Background A generally acceptable definition and a severity grading system for anastomotic leakages (ALs) following rectal resection were not available until 2010, when the International Study Group of Rectal Cancer (ISGRC) proposed a definition and a grading system for AL. Methods A search for published data was performed using the MEDLINE database (2000 to December 5, 2012) to perform a systematic review of the studies that described AL, grade AL according to the grading system, pool data, and determine the average rate of AL for each grade after anterior resection (AR) for rectal cancer. Results A total of 930 abstracts were retrieved; 40 articles on AR, 25 articles on low AR (LAR), and 5 articles on ultralow AR (ULAR) were included in the review and analysis. The pooled overall AL rate of AR was 8.58% (2,085/24,288); the rate of the asymptomatic leakage (Grade A) was 2.57%, that of AL that required active intervention without relaparotomy (Grade B) was 2.37%, and that of AL that required relaparotomy (Grade C) was 5.40%. The pooled rate of AL that required relaparotomy was higher in AR (5.40%) than in LAR (4.70%) and in ULAR (1.81%), which could be attributed to the higher rate of protective defunctioning stoma in LAR (40.72%) and ULAR (63.44%) compared with that in AR (30.11%). Conclusions The new grading system is simple that the ALs of each grade can be easily extracted from past publications, therefore likely to be accepted and applied in future studies. PMID:24086552
Automated Grading of Rough Hardwood Lumber
Richard W. Conners; Tai-Hoon Cho; Philip A. Araman
1989-01-01
Any automatic hardwood grading system must have two components. The first of these is a computer vision system for locating and identifying defects on rough lumber. The second is a system for automatically grading boards based on the output of the computer vision system. This paper presents research results aimed at developing the first of these components. The...
Eghrari, Allen O; Garrett, Brian S; Mumtaz, Aisha A; Edalati, Armand E; Meadows, Danielle N; McGlumphy, Elyse J; Iliff, Benjamin W; Gottsch, John D
2015-12-01
Retroillumination photography analysis (RPA) provides an objective assessment of the number and distribution of guttae in Fuchs corneal dystrophy. Here, we assess its correlation with clinical grading using slit-lamp biomicroscopy across varying levels of severity. Retroillumination photographs were conducted for 95 affected corneas with slit-lamp flash photography after pupillary dilation. Individual guttae were counted manually and the position of individual points recorded. Clinical grading using the Krachmer scale was documented for each eye during examination, and regression analyses were performed to identify the strength of association with number of guttae. We assessed range at each stage of clinical grading and used the Mann-Whitney U test to assess whether clinical grading levels demonstrated successively higher numbers of guttae. Krachmer score ranged from 1 to 5, with mean of 2.6. Mean numbers of guttae at each level of severity were 289 (1+), 999 (2+), 2669 (3+), 5474 (4+), and 7133 (5+). Each stage demonstrated significantly higher numbers of guttae than its preceding level except from 4+ to 5+ (P = 0.30), consistent with the definition of 4+ as the highest level defined by the presence of guttae. Higher levels of clinical grading were associated with larger ranges of guttae (P < 0.01). A linear regression model resulted in a strong fit between RPA and Krachmer score (r = 0.81). In this largest study of RPA data and comparison with subjective clinical grading of Fuchs dystrophy severity, RPA correlates strongly and demonstrates enhanced definition of severity at advanced stages of disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cartier, Lysian; Auberdiac, Pierre; Khodri, Mustapha
The purpose of this study was to analyze and revisit toxicity related to chest chemoradiotherapy and to correlate these side effects with dosimetric parameters obtained using analytical anisotropic algorithm (AAA) in locally unresectable advanced lung cancer. We retrospectively analyzed data from 47 lung cancer patients between 2005 and 2008. All received conformal 3D radiotherapy using high-energy linear accelerator plus concomitant chemotherapy. All treatment planning data were transferred into Eclipse 8.05 (Varian Medical Systems, Palo Alto, CA) and dosimetric calculations were performed using AAA. Thirty-three patients (70.2%) developed acute pneumopathy after radiotherapy (grades 1 and 2). One patient (2.1%) presented withmore » grade 3 pneumopathy. Thirty-one (66%) presented with grades 1-2 lung fibrosis, and 1 patient presented with grade 3 lung fibrosis. Thirty-four patients (72.3%) developed grade 1-2 acute oesophagic toxicity. Four patients (8.5%) presented with grades 3 and 4 dysphagia, necessitating prolonged parenteral nutrition. Median prescribed dose was 64 Gy (range 50-74) with conventional fractionation (2 Gy per fraction). Dose-volume constraints were respected with a median V20 of 23.5% (maximum 34%) and a median V30 of 17% (maximum 25%). The median dose delivered to healthy contralateral lung was 13.1 Gy (maximum 18.1 Gy). At univariate analysis, larger planning target volume and V20 were significantly associated with the probability of grade {>=}2 radiation-induced pneumopathy (p = 0.022 and p = 0.017, respectively). No relation between oesophagic toxicity and clinical/dosimetric parameters could be established. Using AAA, the present results confirm the predictive value of the V20 for lung toxicity as already demonstrated with the conventional pencil beam convolution approach.« less
Jesinghaus, Moritz; Strehl, Johanna; Boxberg, Melanie; Brühl, Frido; Wenzel, Adrian; Konukiewitz, Björn; Schlitter, Anna M; Steiger, Katja; Warth, Arne; Schnelzer, Andreas; Kiechle, Marion; Beckmann, Matthias W; Noske, Aurelia; Hartmann, Arndt; Mehlhorn, Grit; Koch, Martin C; Weichert, Wilko
2018-04-01
A novel histopathological grading system based on tumour budding and cell nest size has recently been shown to outperform conventional (WHO-based) grading algorithms in several tumour entities such as lung, oral, and oesophageal squamous cell carcinoma (SCC) in terms of prognostic patient stratification. Here, we tested the prognostic value of this innovative grading approach in two completely independent cohorts of SCC of the uterine cervix. To improve morphology-based grading, we investigated tumour budding activity and cell nest size as well as several other histomorphological factors (e.g., keratinization, nuclear size, mitotic activity) in a test cohort (n = 125) and an independent validation cohort (n = 122) of cervical SCC. All parameters were correlated with clinicopathological factors and patient outcome. Small cell nest size and high tumour budding activity were strongly associated with a dismal patient prognosis (p < 0.001 for overall survival [OS], disease-specific survival, and disease-free survival; test cohort) in both cohorts of cervical SCC. A novel grading algorithm combining these two parameters proved to be a highly effective, stage-independent prognosticator in both cohorts (OS: p < 0.001, test cohort; p = 0.001, validation cohort). In the test cohort, multivariate statistical analysis of the novel grade revealed that the hazard ratio (HR) for OS was 2.3 for G2 and 5.1 for G3 tumours compared to G1 neoplasms (p = 0.010). In the validation cohort, HR for OS was 3.0 for G2 and 7.2 for G3 tumours (p = 0.012). In conclusion, our novel grading algorithm incorporating cell nest size and tumour budding allows strongly prognostic histopathological grading of cervical SCC superior to WHO-based grading. Therefore, our data can be regarded as a cross-organ validation of previous results demonstrated for oesophageal, lung, and oral SCC. We suggest this grading algorithm as an additional morphology-based parameter for the routine diagnostic assessment of this tumour entity. © 2018 The Authors The Journal of Pathology: Clinical Research published by The Pathological Society of Great Britain and Ireland and John Wiley & Sons Ltd.
Independent surgical validation of the new prostate cancer grade-grouping system.
Spratt, Daniel E; Cole, Adam I; Palapattu, Ganesh S; Weizer, Alon Z; Jackson, William C; Montgomery, Jeffrey S; Dess, Robert T; Zhao, Shuang G; Lee, Jae Y; Wu, Angela; Kunju, Lakshmi P; Talmich, Emily; Miller, David C; Hollenbeck, Brent K; Tomlins, Scott A; Feng, Felix Y; Mehra, Rohit; Morgan, Todd M
2016-11-01
To report the independent prognostic impact of the new prostate cancer grade-grouping system in a large external validation cohort of patients treated with radical prostatectomy (RP). Between 1994 and 2013, 3 694 consecutive men were treated with RP at a single institution. To investigate the performance of and validate the grade-grouping system, biochemical recurrence-free survival (bRFS) rates were assessed using Kaplan-Meier tests, Cox-regression modelling, and discriminatory comparison analyses. Separate analyses were performed based on biopsy and RP grade. The median follow-up was 52.7 months. The 5-year actuarial bRFS for biopsy grade groups 1-5 were 94.2%, 89.2%, 73.1%, 63.1%, and 54.7%, respectively (P < 0.001). Similarly, the 5-year actuarial bRFS based on RP grade groups was 96.1%, 93.0%, 74.0%, 64.4%, and 49.9% for grade groups 1-5, respectively (P < 0.001). The adjusted hazard ratios for bRFS relative to biopsy grade group 1 were 1.98, 4.20, 5.57, and 9.32 for groups 2, 3, 4, and 5, respectively (P < 0.001), and for RP grade groups were 2.09, 5.27, 5.86, and 10.42 (P < 0.001). The five-grade-group system had a higher prognostic discrimination compared with the commonly used three-tier system (Gleason score 6 vs 7 vs 8-10). In an independent surgical cohort, we have validated the prognostic benefit of the new prostate cancer grade-grouping system for bRFS, and shown that the benefit is maintained after adjusting for important clinicopathological variables. The greater predictive accuracy of the new system will improve risk stratification in the clinical setting and aid in patient counselling. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
Prospective validation of a surgical complications grading system in a cohort of 2114 patients.
Mazeh, Haggi; Cohen, Oded; Mizrahi, Ido; Hamburger, Tamar; Stojadinovic, Alexander; Abu-Wasel, Bassam; Alaiyan, Bilal; Freund, Herbert R; Eid, Ahmed; Nissan, Aviram
2014-05-01
We recently reported a grading system for surgical complications. This system proved to have a high sensitivity for recording minor but meaningful complications prolonging hospital stay in patients after colorectal surgery. We aimed to prospectively validate the complication grading system in a general surgery department over 1 year. All surgical procedures and related complications were prospectively recorded between January 1st and December 31st, 2009. Surgical complications were graded on a severity scale of 1-5. The system classifies short-term outcome by grade emphasizing intensity of therapy required for treatment of the defined complication. During the study period, 2114 patients underwent surgery. Elective and oncological surgeries were performed in 1606 (76%) and 465 (22%) patients, respectively. There were 422 surgical complications in 304 (14%) patients (Grade 1/2: 203 [67%]; Grade 3/4: 90 [29%]; Grade 5: 11 [4%]). Median length of stay correlated significantly with complication severity: 2.3 d for no complication, 6.2 and 11.8 d for Grades 1/2 and 3/4, respectively (P < 0.001). Older age (OR 2.75, P < 0.001), comorbidities (OR 1.44, P = 0.02), American Society of Anesthesiology score >2 (OR 2.07, P < 0.001), contamination Grade (OR 1.85, P = 0.001), oncological (OR 2.82, P < 0.001), open (OR 1.22, P = 0.03), prolonged >120 min (OR 2.08, P < 0.001), and emergency surgery (OR 1.42, P = 0.02) independently predicted postoperative complications. This system of grading surgical complications permits standardized reporting of surgical morbidity according to the severity of impact. Prospective validation of this system supports its use in a general surgery setting as a tool for surgical outcome assessment and quality assurance. Copyright © 2014 Elsevier Inc. All rights reserved.
Kulkarni, H R; Kamal, M M; Arjune, D G
1999-12-01
The scoring system developed by Mair et al. (Acta Cytol 1989;33:809-813) is frequently used to grade the quality of cytology smears. Using a one-factor analytic structural equations model, we demonstrate that the errors in measurement of the parameters used in the Mair scoring system are highly and significantly correlated. We recommend the use of either a multiplicative scoring system, using linear scores, or an additive scoring system, using exponential scores, to correct for the correlated errors. We suggest that the 0, 1, and 2 points used in the Mair scoring system be replaced by 1, 2, and 4, respectively. Using data on fine-needle biopsies of 200 thyroid lesions by both fine-needle aspiration (FNA) and fine-needle capillary sampling (FNC), we demonstrate that our modification of the Mair scoring system is more sensitive and more consistent with the structural equations model. Therefore, we recommend that the modified Mair scoring system be used for classifying the diagnostic adequacy of cytology smears. Diagn. Cytopathol. 1999;21:387-393. Copyright 1999 Wiley-Liss, Inc.
Compact instrument for fluorescence image-guided surgery
NASA Astrophysics Data System (ADS)
Wang, Xinghua; Bhaumik, Srabani; Li, Qing; Staudinger, V. Paul; Yazdanfar, Siavash
2010-03-01
Fluorescence image-guided surgery (FIGS) is an emerging technique in oncology, neurology, and cardiology. To adapt intraoperative imaging for various surgical applications, increasingly flexible and compact FIGS instruments are necessary. We present a compact, portable FIGS system and demonstrate its use in cardiovascular mapping in a preclinical model of myocardial ischemia. Our system uses fiber optic delivery of laser diode excitation, custom optics with high collection efficiency, and compact consumer-grade cameras as a low-cost and compact alternative to open surgical FIGS systems. Dramatic size and weight reduction increases flexibility and access, and allows for handheld use or unobtrusive positioning over the surgical field.
2010-08-19
highlight the benefits of regenerative braking . Parameters within the drive cycle may include vehicle speed, elevation/grade changes, road surface...assist to downsize the engine due to infinite maximum speed requirements • Drive cycle less suited to regenerative braking improvement compared to...will be cycle dependent. A high speed drive cycle may for example drive a focus on aerodynamic improvements, while high frequency of braking will
Slater, M; Iler, E
1991-04-01
The Gateway to Higher Education program is a comprehensive four-year high school program with specially designed enrichments and supports. Its principal goal is to increase the number of minority students who will be prepared to enter training for high-level professional careers, especially in medicine and science. The program was established in September 1986 to demonstrate that minority students who perform at least at grade level can begin a rigorous curriculum in the ninth grade and achieve outstanding results, provided that the necessary support systems are in place. For 1990-91, 750 students are enrolled in Gateway programs at five New York City public high schools, and the first 119 students graduated in June 1990. The graduates have demonstrated significant achievement compared with that of their peers, as measured by standardized tests and the graduates' participation in research mentorships and college acceptances. In order to expand on its initial success, the program has increased its scope of activity to include over 400 students at the junior high school level.
The Changing Landscape of Grading Systems in US Higher Education
ERIC Educational Resources Information Center
Kleinman, Steven B.; Leidman, Mary Beth; Longcore, Andrew J.
2018-01-01
The following study explores the landscape of grading systems utilised in higher education, focusing on the frequency of different types of assessment scales (including Straight Letter, Plus/Minus, and other alternative policies). Although numerous studies have explored the relationship between university grading system and student behaviour,…
49 CFR 212.231 - Highway-rail grade crossing inspector.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Control Devices; and (6) Knowledge of railroad signal systems sufficient to ensure that highway-rail grade... signal systems. (d) A State signal and train control inspector qualified under this part and who has... independent inspections of all types of highway-rail grade crossing warning systems for the purpose of...
49 CFR 212.231 - Highway-rail grade crossing inspector.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Control Devices; and (6) Knowledge of railroad signal systems sufficient to ensure that highway-rail grade... signal systems. (d) A State signal and train control inspector qualified under this part and who has... independent inspections of all types of highway-rail grade crossing warning systems for the purpose of...
Grading System and Student Effort
ERIC Educational Resources Information Center
Paredes, Valentina
2017-01-01
Several papers have proposed that the grading system affects students' incentives to exert effort. In particular, the previous literature has compared student effort under relative and absolute grading systems, but the results are mixed and the implications of the models have not been empirically tested. In this paper, I build a model where…
ERIC Educational Resources Information Center
Maeder, Jacqueline; And Others
The revisions on the Learning Mastery Systems (LMSs) for the Harper & Row grade-one and grade-two and the Macmillan Bank Street grade-one reading programs are outlined in this document. A rationale for the revisions is presented. An LMS is a set of materials and procedures prepared by the southwest Regional Laboratory (SWRL) as an…
Expression of monellin in a food-grade delivery system in Saccharomyces cerevisiae.
Liu, Jun; Yan, Da-zhong; Zhao, Sheng-jun
2015-10-01
Genetically modified (GM) foods have caused much controversy. Construction of a food-grade delivery system is a desirable technique with presumptive impact on industrial applications from the perspective of bio-safety. The aim of this study was to construct a food-grade delivery system for Saccharomyces cerevisiae and to study the expression of monellin from the berries of the West African forest plant Dioscoreophyllum cumminsii in this system. A food-grade system for S. cerevisiae was constructed based on ribosomal DNA (rDNA)-mediated homologous recombination to enable high-copy-number integration of the expression cassette inserted into the rDNA locus. A copper resistance gene (CUP1) was used as the selection marker for yeast transformation. Because variants of transformants containing different copy numbers at the CUP1 locus can be readily selected after growth in the presence of elevated copper levels, we suggest that this system would prove useful in the generation of tandemly iterated gene clusters. Using this food-grade system, a single-chain monellin gene was heterologously expressed. The yield of monellin reached a maximum of 675 mg L(-1) . This system harbors exclusively S. cerevisiae DNA with no antibiotic resistance genes, and it should therefore be appropriate for safe use in the food industry. Monellin was shown to be expressed in this food-grade delivery system. To our knowledge, this is the first report so far on expression of monellin in a food-grade expression system in S. cerevisiae. © 2014 Society of Chemical Industry.
An introduction to UGRS: the ultimate grading and remanufacturing system
John Moody; Charles J. Gatchell; Elizabeth S. Walker; Powsiri Klinkhachorn
1998-01-01
The Ultimate Grading and Remanufactming System (UGRS) is an advanced computer program for grading and remanufacturing lumber. It is an interactive program that will both grade lumber according to NHLA rules and remanufacture it for maximum value. UGRS is written to run under Microsoft Windows 3.0 or later updates and provides a sophisticated graphical user interface....
Delahunt, B; Egevad, L; Srigley, J R; Steigler, A; Murray, J D; Atkinson, C; Matthews, J; Duchesne, G; Spry, N A; Christie, D; Joseph, D; Attia, J; Denham, J W
2015-10-01
In 2014 a consensus conference convened by the International Society of Urological Pathology (ISUP) adopted amendments to the criteria for Gleason grading and scoring (GS) for prostatic adenocarcinoma. The meeting defined a modified grading system based on 5 grading categories (grade 1, GS 3+3; grade 2, GS 3+4; grade 3, GS 4+3; grade 4, GS 8; grade 5, GS 9-10). In this study we have evaluated the prognostic significance of ISUP grading in 496 patients enrolled in the TROG 03.04 RADAR Trial. There were 19 grade 1, 118 grade 2, 193 grade 3, 88 grade 4 and 79 grade 5 tumours in the series, with follow-up for a minimum of 6.5 years. On follow-up 76 patients experienced distant progression of disease, 171 prostate specific antigen (PSA) progression and 39 prostate cancer deaths. In contrast to the 2005 modified Gleason system (MGS), the hazards of the distant and PSA progression endpoints, relative to grade 2, were significantly greater for grades 3, 4 and 5 of the 2014 ISUP grading scheme. Comparison of predictive ability utilising Harrell's concordance index, showed 2014 ISUP grading to significantly out-perform 2005 MGS grading for each of the three clinical endpoints.
NASA Astrophysics Data System (ADS)
Doganca Kucuk, Zerrin; Saysel, Ali Kerem
2017-03-01
A systems-based classroom intervention on environmental education was designed for seventh grade students; the results were evaluated to see its impact on the development of systems thinking skills and standard science achievement and whether the systems approach is a more effective way to teach environmental issues that are dynamic and complex. A quasi-experimental methodology was used to compare performances of the participants in various dimensions, including systems thinking skills, competence in dynamic environmental problem solving and success in science achievement tests. The same pre-, post- and delayed tests were used with both the comparison and experimental groups in the same public middle school in Istanbul. Classroom activities designed for the comparison group (N = 20) followed the directives of the Science and Technology Curriculum, while the experimental group (N = 22) covered the same subject matter through activities benefiting from systems tools and representations such as behaviour over time graphs, causal loop diagrams, stock-flow structures and hands-on dynamic modelling. After a one-month systems-based instruction, the experimental group demonstrated significantly better systems thinking and dynamic environmental problem solving skills. Achievement in dynamic problem solving was found to be relatively stable over time. However, standard science achievement did not improve at all. This paper focuses on the quantitative analysis of the results, the weaknesses of the curriculum and educational implications.
1986-07-01
qualified lubricants were employed in the test, one product at each of the test locations. The test lubricants were used in all equipment components...Overall, the grade 15W-40 products demonstrated satisfactory and equivalent performance to single-graded oils. The oil was well received by both...operators and maintenance personnel who noted that the grade 15W-40 products significantly reduced logistics burden by having only one grade product to
ERIC Educational Resources Information Center
Sircey, Samantha Taylor
2017-01-01
In the middle school setting, reading is a requirement if students are to access the curriculum and demonstrate content proficiency. By grade three, students are expected to read on grade level, but by middle grades (7-8), some students still struggle with reading for comprehension. In addition, some middle school teachers struggle to implement…
ERIC Educational Resources Information Center
Mann, Michael J.; Kristjansson, Alfgeir L.; Smith, Megan L.; Sigfusdottir, Inga Dora
2016-01-01
Younger adolescents demonstrate a greater vulnerability to negative life events than do older adolescents and adults. The authors examined whether this heightened vulnerability includes a greater likelihood for participating in problem behaviors associated with poor academic outcomes and receiving lower grades. The study was conducted using data…
ERIC Educational Resources Information Center
Clark, Mary L.
2012-01-01
Students reading below grade proficiency have been a concern for educators. Students who attended third grade at this Title 1 intermediate school have demonstrated a lack of early literacy skills as measured using a variety of assessments. An early literacy reading program was initiated in 2008; however, the effectiveness of the instructional…
Jaakkola, Timo; Hillman, Charles; Kalaja, Sami; Liukkonen, Jarmo
2015-01-01
The purpose of this study was to analyse the longitudinal associations between (1) fundamental movement skills (FMSs) and academic performance, and (2) self-reported physical activity and academic performance through junior high school in Finland. The participants of the study were 325 Finnish students (162 girls and 163 boys), who were 13 years old at the beginning of the study at Grade 7. Students performed three FMS tests and responded to a self-reported physical activity questionnaire at Grades 7 and 8. Marks in Finnish language, mathematics and history from Grades 7, 8 and 9 were collected. Structural equation modelling with multigroup method demonstrated that in the boys' group, a correlation (0.17) appeared between FMS and academic performance measured at Grade 7. The results also indicated that FMS collected at Grade 8 were significantly but weakly (path coefficient 0.14) associated with academic performance at Grade 9 for both gender groups. Finally, the results of this study demonstrated that self-reported physical activity was not significantly related to academic performance during junior high school. The findings of this study suggest that mastery of FMS may contribute to better student achievement during junior high school.
Hunter, Ross J; Diab, Ihab; Thomas, Glyn; Duncan, Edward; Abrams, Dominic; Dhinoja, Mehul; Sporton, Simon; Earley, Mark J; Schilling, Richard J
2009-12-01
We tested application of a grading system describing complex fractionated electrograms (CFE) in atrial fibrillation (AF) and used it to validate automated CFE detection (AUTO). Ten seconds bipolar electrograms were classified by visual inspection (VI) during ablation of persistent AF and the result compared with offline manual measurement (MM) by a second blinded operator: Grade 1 uninterrupted fractionated activity (defined as segments > or =70 ms) for > or =70% of recording and uninterrupted > or =1 s; Grade 2 interrupted fractionated activity > or =70% of recording; Grade 3 intermittent fractionated activity 30-70%; Grade 4 discrete (<70 ms) complex electrogram (> or =5 direction changes); Grade 5 discrete simple electrograms (< or =4 direction changes); Grade 6 scar. Grade by VI and MM for 100 electrograms agreed in 89%. Five hundred electrograms were graded on Carto and NavX by VI to validate AUTO in (i) detection of CFE (grades 1-4 considered CFE), and (ii) assessing degree of fractionation by correlating grade and score by AUTO (data shown as sensitivity, specificity, r): NavX 'CFE mean' 92%, 91%, 0.56; Carto 'interval confidence level' using factory settings 89%, 62%, -0.72, and other published settings 80%, 74%, -0.65; Carto 'shortest confidence interval' 74%, 70%, 0.43; Carto 'average confidence interval' 86%, 66%, 0.53. Grading CFE by VI is accurate and correlates with AUTO.
Neuropathic pain: an updated grading system for research and clinical practice
Finnerup, Nanna B.; Haroutounian, Simon; Kamerman, Peter; Baron, Ralf; Bennett, David L.H.; Bouhassira, Didier; Cruccu, Giorgio; Freeman, Roy; Hansson, Per; Nurmikko, Turo; Raja, Srinivasa N.; Rice, Andrew S.C.; Serra, Jordi; Smith, Blair H.; Treede, Rolf-Detlef; Jensen, Troels S.
2016-01-01
Abstract The redefinition of neuropathic pain as “pain arising as a direct consequence of a lesion or disease affecting the somatosensory system,” which was suggested by the International Association for the Study of Pain (IASP) Special Interest Group on Neuropathic Pain (NeuPSIG) in 2008, has been widely accepted. In contrast, the proposed grading system of possible, probable, and definite neuropathic pain from 2008 has been used to a lesser extent. Here, we report a citation analysis of the original NeuPSIG grading paper of 2008, followed by an analysis of its use by an expert panel and recommendations for an improved grading system. As of February, 2015, 608 eligible articles in Scopus cited the paper, 414 of which cited the neuropathic pain definition. Of 220 clinical studies citing the paper, 56 had used the grading system. The percentage using the grading system increased from 5% in 2009 to 30% in 2014. Obstacles to a wider use of the grading system were identified, including (1) questions about the relative significance of confirmatory tests, (2) the role of screening tools, and (3) uncertainties about what is considered a neuroanatomically plausible pain distribution. Here, we present a revised grading system with an adjusted order, better reflecting clinical practice, improvements in the specifications, and a word of caution that even the “definite” level of neuropathic pain does not always indicate causality. In addition, we add a table illustrating the area of pain and sensory abnormalities in common neuropathic pain conditions and propose areas for further research. PMID:27115670
Shaulsky, Evyatar; Boo, Chanhee; Lin, Shihong; Elimelech, Menachem
2015-05-05
We present a hybrid osmotic heat engine (OHE) system that uses draw solutions with an organic solvent for enhanced thermal separation efficiency. The hybrid OHE system produces sustainable energy by combining pressure-retarded osmosis (PRO) as a power generation stage and membrane distillation (MD) utilizing low-grade heat as a separation stage. While previous OHE systems employed aqueous electrolyte draw solutions, using methanol as a solvent is advantageous because methanol is highly volatile and has a lower heat capacity and enthalpy of vaporization than water. Hence, the thermal separation efficiency of a draw solution with methanol would be higher than that of an aqueous draw solution. In this study, we evaluated the performance of LiCl-methanol as a potential draw solution for a PRO-MD hybrid OHE system. The membrane transport properties as well as performance with LiCl-methanol draw solution were evaluated using thin-film composite (TFC) PRO membranes and compared to the results obtained with a LiCl-water draw solution. Experimental PRO methanol flux and maximum projected power density of 47.1 L m(-2) h(-1) and 72.1 W m(-2), respectively, were achieved with a 3 M LiCl-methanol draw solution. The overall efficiency of the hybrid OHE system was modeled by coupling the mass and energy flows between the thermal separation (MD) and power generation (PRO) stages under conditions with and without heat recovery. The modeling results demonstrate higher OHE energy efficiency with the LiCl-methanol draw solution compared to that with the LiCl-water draw solution under practical operating conditions (i.e., heat recovery<90%). We discuss the implications of the results for converting low-grade heat to power.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaulsky, E; Boo, C; Lin, SH
We present a hybrid osmotic heat engine (OHE) system that uses draw solutions with an organic solvent for enhanced thermal separation efficiency. The hybrid OHE system produces sustainable energy by combining pressure-retarded osmosis (PRO) as a power generation stage and membrane distillation (MD) utilizing low-grade heat as a separation stage. While previous OHE systems employed aqueous electrolyte draw solutions, using methanol as a solvent is advantageous because methanol is highly volatile and has a lower heat capacity and enthalpy of vaporization than water. Hence, the thermal separation efficiency of a draw solution with methanol would be higher than that ofmore » an aqueous draw solution. In this study, we evaluated the performance of LiCl-methanol as a potential draw solution for a PRO-MD hybrid OHE system. The membrane transport properties as well as performance with LiCl methanol draw solution were evaluated using thin-film composite (TFC) PRO membranes and compared to the results obtained with a LiCl water draw solution. Experimental PRO methanol flux and maximum projected power density of 47.1 L m(-2) h(-1) and 72.1 W m(-2), respectively, were achieved with a 3 M LiCl-methanol draw solution. The overall efficiency of the hybrid OHE system was modeled by coupling the mass and energy flows between the thermal separation (MD) and power generation (PRO) stages under conditions with and without heat recovery. The modeling results demonstrate higher ORE energy efficiency with the LiCl methanol draw solution compared to that with the LiCl water draw solution under practical operating conditions (i.e., heat recovery <90%). We discuss the implications of the results for converting low-grade heat to power.« less
An analysis technique for testing log grades
Carl A. Newport; William G. O' Regan
1963-01-01
An analytical technique that may be used in evaluating log-grading systems is described. It also provides means of comparing two or more grading systems, or a proposed change with the system from which it was developed. The total volume and computed value of lumber from each sample log are the basic data used.
Câmara, P R; Dutra, S N; Takahama Júnior, A; Fontes, Kbfc; Azevedo, R S
2016-09-01
To evaluate comparatively the influence of histopathological features on epithelial dysplasia (ED) and the effectiveness in usage of WHO and binary grading systems in actinic cheilitis (AC). Cytological and architectural alterations established by WHO for ED were evaluated in 107 cases of AC. Epithelial dysplasia was graded using WHO and binary systems. The comparisons were performed using kappa, chi-square, and phi coefficient tests (P < 0.05). Most cases were classified as mild ED (44.5%) in the WHO system and as low risk for malignant transformation (64.5%) in the binary system. There was a positive correlation between WHO and binary systems (k = 0.33; P < 0.0002). Loss of basal cell polarity (P < 0.001) was associated with severity of ED grade in the WHO system. Anisonucleosis (P < 0.0001), nuclear pleomorphism (P < 0.0001), anisocytosis (P = 0.03), cell pleomorphism (P = 0.002) increased nuclear/cytoplasm ratio (P < 0.0001), increased nuclear size (P < 0.0001), increased number of mitotic figures (P = 0.0006), and dyskeratosis (P = 0.008) were associated with severity of ED grade in the binary system. It seems that usage of binary ED grading system in AC may be more precise because there is correlation between many of cytological and some of architectural microscopic alterations with increased grade of ED. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Application of a Musical Whistling Certificate Examination System as a Group Examination
NASA Astrophysics Data System (ADS)
Mori, Mikio; Ogihara, Mitsuhiro; Sugahara, Shin-Ichi; Taniguchi, Shuji; Kato, Shozo; Araki, Chikahiro
Recently, some professional whistlers have set up music schools to teach musical whistling. However, so far, there is no licensed examination for musical whistling. In this paper, we propose an examination system for evaluating musical whistling. The system conducts an examination in musical whistling on a personal computer (PC). It can be used to award four grades, from the second to the fifth. These grades are designed according to the standards adopted by the school for musical whistling established by the Japanese professional whistler Moku-San. It is expected that the group examination of this examination is held in the examination center where other general certification examinations are held. Thus, the influence of the whistle sound on the PC microphone normally used should be considered. For this purpose, we examined the feasibility of using a bone-conductive microphone for a musical whistling certificate examination system. This paper shows that the proposed system in which bone-transmitted sounds are considered gives good performance under a noisy environment, as demonstrated in a group examination of musical whistling using bone-transmitted sounds. The timing of a candidates whistling tends to not match because the applause sound output from the PC was inaudible for a person older than 60 years.
NASA Astrophysics Data System (ADS)
El-Sabbagh, A.; Baz, A.
2006-03-01
Conventionally, the viscoelastic cores of Constrained Layer Damping (CLD) treatments are made of materials that have uniform shear modulus. Under such conditions, it is well-recognized that these treatments are only effective near their edges where the shear strains attain their highest values. In order to enhance the damping characteristics of the CLD treatments, we propose to manufacture the cores from Functionally Graded ViscoElastic Materials (FGVEM) that have optimally selected gradient of the shear modulus over the length of the treatments. With such optimized distribution of the shear modulus, the shear strain can be enhanced, and the energy dissipation can be maximized. The theory governing the vibration of beams treated with CLD, that has functionally graded viscoelastic cores, is presented using the finite element method (FEM). The predictions of the FEM are validated experimentally for plain beams, beams treated conventional CLD, and beams with CLD/FGVEM of different configurations. The obtained results indicate a close agreement between theory and experiments. Furthermore, the obtained results demonstrate the effectiveness of the new class of CLD with functionally graded cores in enhancing the energy dissipation over the conventional CLD over a broad frequency band. Extension of the proposed one-dimensional beam/CLD/FGVEM system to more complex structures is a natural extension to the present study.
ERIC Educational Resources Information Center
White, Peter; Syncox, David; Alters, Brian
2011-01-01
Using classroom response systems (clickers) to accumulate grade-points has become a controversial practice as response systems have become more widely used in the last decade. Although some instructors opt to use clickers on a non-grades basis, it has become quite common to reward students for (a) correct answers, (b) participating in clicker…
Marketing low-grade hardwoods for furniture stock - a new approach
Hugh W. Reynolds; Charles J. Gatchell
1979-01-01
A hardwood shortage of high-grade lumber exists while there is a surplus of low-grade hardwood timber. Two things are needed for the surplus to correct the shortage: a new manufacturing system and a new marketing technique. Utilization research at the Princeton Forestry Sciences Laboratory has developed the new system for converting low-grade hardwood for furniture use...
Chirped self-similar waves for quadratic-cubic nonlinear Schrödinger equation
NASA Astrophysics Data System (ADS)
Pal, Ritu; Loomba, Shally; Kumar, C. N.
2017-12-01
We have constructed analytical self-similar wave solutions for quadratic-cubic Nonlinear Schrödinger equation (QC-NLSE) by means of similarity transformation method. Then, we have investigated the role of chirping on these self-similar waves as they propagate through the tapered graded index waveguide. We have revealed that the chirping leads to interesting features and allows us to control the propagation of self-similar waves. This has been demonstrated for two cases (i) periodically distributed system and (ii) constant choice of system parameters. We expect our results to be useful in designing high performance optical devices.
ALBI versus Child-Pugh grading systems for liver function in patients with hepatocellular carcinoma.
Na, Seong K; Yim, Sun Y; Suh, Sang J; Jung, Young K; Kim, Ji H; Seo, Yeon S; Yim, Hyung J; Yeon, Jong E; Byun, Kwan S; Um, Soon H
2018-04-01
The prognostic performance of the albumin-bilirubin (ALBI) grade in hepatocellular carcinoma (HCC) as an objective method of assessing liver function was investigated. Data from 2099 patients with HCC in Korea were collected and analyzed retrospectively. The discriminative performance of ALBI grade was compared with Child-Pugh (C-P) grade for different stages or treatments. The median follow up duration was 16.2 months (range: 1.0-124.9). The median survival times were 49.7 months for C-P grade A (65.8%), 12.4 months for C-P grade B (25.5%), and 4.2 months for C-P grade C (8.6%) (P < 0.001). The median survival times were 84.2 months for ALBI grade 1 (32.8%), 25.5 months for ALBI grade 2 (53.5%), and 7.7 months for ALBI grade 3 (13.7%) (P < 0.001). In early UICC stages, ALBI grade showed better discriminative performance than C-P grade. In curative treatments, ALBI grade also showed better discriminative performance than C-P grade (Harrell's C: 0.624 (C-P grade) vs 0.667 [ALBI grade]). ALBI grade provided better prognostic performance in survival analysis and better distribution of the grades than C-P grade in HCC, suggesting that ALBI grade could be a good alternative grading system for liver function in patients with HCC. © 2018 Wiley Periodicals, Inc.
Gomes, Carlos Augusto; Sartelli, Massimo; Di Saverio, Salomone; Ansaloni, Luca; Catena, Fausto; Coccolini, Federico; Inaba, Kenji; Demetriades, Demetrios; Gomes, Felipe Couto; Gomes, Camila Couto
2015-01-01
Advances in the technology and improved access to imaging modalities such as Computed Tomography and laparoscopy have changed the contemporary diagnostic and management of acute appendicitis. Complicated appendicitis (phlegmon, abscess and/ or diffuse peritonitis), is now reliably distinguished from uncomplicated cases. Therefore, a new comprehensive grading system for acute appendicitis is necessary. The goal is review and update the laparoscopic grading system of acute appendicitis and to provide a new standardized classification system to allow more uniform patient stratification. During the last World Society of Emergency Surgery Congress in Israel (July, 2015), a panel involving Acute Appendicitis Experts and the author's discussed many current aspects about the acute appendicitis between then, it will be submitted a new comprehensive disease grading system. It was idealized based on three aspect of the disease (clinical and imaging presentation and laparoscopic findings). The new grading system may provide a standardized system to allow more uniform patient stratification for appendicitis research. In addition, may aid in determining optimal management according to grade. Lastly, what we want is to draw a multicenter observational study within the World Society of Emergency Surgery (WSES) based on this design.
Aggarwal, Ashish; Dhandapani, Sivashanmugam; Praneeth, Kokkula; Sodhi, Harsimrat Bir Singh; Pal, Sudhir Singh; Gaudihalli, Sachin; Khandelwal, N; Mukherjee, Kanchan K; Tewari, M K; Gupta, Sunil Kumar; Mathuriya, S N
2018-01-01
The comparative studies on grading in subarachnoid hemorrhage (SAH) had several limitations such as the unclear grading of Glasgow Coma Scale 15 with neurological deficits in World Federation of Neurosurgical Societies (WFNS), and the inclusion of systemic disease in Hunt and Hess (H&H) scales. Their differential incremental impacts and optimum cut-off values for unfavourable outcome are unsettled. This is a prospective comparison of prognostic impacts of grading schemes to address these issues. SAH patients were assessed using WFNS, H&H (including systemic disease), modified H&H (sans systemic disease) and followed up with Glasgow Outcome Score (GOS) at 3 months. Their performance characteristics were analysed as incremental ordinal variables and different grading scale dichotomies using rank-order correlation, sensitivity, specificity, positive predictive value, negative predictive value, Youden's J and multivariate analyses. A total of 1016 patients were studied. As univariate incremental variable, H&H sans systemic disease had the best negative rank-order correlation coefficient (-0.453) with respect to lower GOS (p < 0.001). As univariate dichotomized category, WFNS grades 3-5 had the best performance index of 0.39 to suggest unfavourable GOS with a specificity of 89% and sensitivity of 51%. In multivariate incremental analysis, H&H sans systemic disease had the greatest adjusted incremental impact of 0.72 (95% confidence interval (CI) 0.54-0.91) against a lower GOS as compared to 0.6 (95% CI 0.45-0.74) and 0.55 (95% CI 0.42-0.68) for H&H and WFNS grades, respectively. In multivariate categorical analysis, H&H grades 4-5 sans systemic disease had the greatest impact on unfavourable GOS with an adjusted odds ratio of 6.06 (95% CI 3.94-9.32). To conclude, H&H grading sans systemic disease had the greatest impact on unfavourable GOS. Though systemic disease is an important prognostic factor, it should be considered distinctly from grading. Appropriate cut-off values suggesting unfavourable outcome for H&H and WFNS were 4-5 and 3-5, respectively, indicating the importance of neurological deficits in addition to level of consciousness.
A Thermally-Regenerative Ammonia-Based Flow Battery for Electrical Energy Recovery from Waste Heat.
Zhu, Xiuping; Rahimi, Mohammad; Gorski, Christopher A; Logan, Bruce
2016-04-21
Large amounts of low-grade waste heat (temperatures <130 °C) are released during many industrial, geothermal, and solar-based processes. Using thermally-regenerative ammonia solutions, low-grade thermal energy can be converted to electricity in battery systems. To improve reactor efficiency, a compact, ammonia-based flow battery (AFB) was developed and tested at different solution concentrations, flow rates, cell pairs, and circuit connections. The AFB achieved a maximum power density of 45 W m(-2) (15 kW m(-3) ) and an energy density of 1260 Wh manolyte (-3) , with a thermal energy efficiency of 0.7 % (5 % relative to the Carnot efficiency). The power and energy densities of the AFB were greater than those previously reported for thermoelectrochemical and salinity-gradient technologies, and the voltage or current could be increased using stacked cells. These results demonstrated that an ammonia-based flow battery is a promising technology to convert low-grade thermal energy to electricity. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Offermann, Anne; Hohensteiner, Silke; Kuempers, Christiane; Ribbat-Idel, Julika; Schneider, Felix; Becker, Finn; Hupe, Marie Christine; Duensing, Stefan; Merseburger, Axel S; Kirfel, Jutta; Reischl, Markus; Lubczyk, Verena; Kuefer, Rainer; Perner, Sven
2017-01-01
Gleason grading is the best independent predictor for prostate cancer (PCa) progression. Recently, a new PCa grading system has been introduced by the International Society of Urological Pathology (ISUP) and is recommended by the World Health Organization (WHO). Following studies observed more accurate and simplified grade stratification of the new system. Aim of this study was to compare the prognostic value of the new grade groups compared to the former Gleason Grading and to determine whether re-definition of Gleason Pattern 4 might reduce upgrading from prostate biopsy to radical prostatectomy (RP) specimen. A cohort of men undergoing RP from 2002 to 2015 at the Hospital of Goeppingen (Goeppingen, Germany) was used for this study. In total, 339 pre-operative prostatic biopsies and corresponding RP specimens, as well as additional 203 RP specimens were re-reviewed for Grade Groups according to the ISUP. Biochemical recurrence-free survival (BFS) after surgery was used as endpoint to analyze prognostic significance. Other clinicopathological data included TNM-stage and pre-operative PSA level. Kaplan-Meier analysis revealed risk stratification of patients based on both former Gleason Grading and ISUP Grade Groups, and was statistically significant using the log-rank test ( p < 0.001). Both grading systems significantly correlated with TNM-stage and pre-operative PSA level ( p < 0.001). Higher tumor grade in RP specimen compared to corresponding pre-operative biopsy was observed in 44 and 34.5% of cases considering former Gleason Grading and ISUP Grade Groups, respectively. Both, former Gleason Grading and ISUP Grade Groups predict survival when applied on tumors in prostatic biopsies as well as RP specimens. This is the first validation study on a large representative German community-based cohort to compare the former Gleason Grading with the recently introduced ISUP Grade Groups. Our data indicate that the ISUP Grade Groups do not improve predictive value of PCa grading and might be less sensitive in deciphering tumors with 3 + 4 and 4 + 3 pattern on RP specimen. However, the Grade Group system results less frequently in an upgrading from biopsy to the corresponding RP specimens, indicating a lower risk to miss potentially aggressive tumors not represented on biopsies.
Eghrari, Allen O.; Garrett, Brian S.; Mumtaz, Aisha A.; Edalati, Armand E.; Meadows, Danielle N.; McGlumphy, Elyse J.; Iliff, Benjamin W.; Gottsch, John D.
2015-01-01
Purpose Retroillumination photography analysis (RPA) provides objective assessment of the number and distribution of guttae in Fuchs Corneal Dystrophy. Here, we assess its correlation with clinical grading using slit-lamp biomicroscopy across varying levels of severity. Methods Retroillumination photographs were conducted of 95 affected corneas with slit-lamp flash photography after pupillary dilation. Individual guttae were counted manually and the position of individual points recorded. Clinical grading using the Krachmer scale was documented for each eye during examination, and regression analyses were performed to identify the strength of association with number of guttae. We assessed range at each stage of clinical grading, and utilized the Mann-Whitney U test to assess whether clinical grading levels demonstrated successively higher numbers of guttae. Results Krachmer score ranged from 1 to 5, with mean of 2.6. Mean numbers of guttae at each level of severity were 289 (1+), 999 (2+), 2669 (3+), 5474 (4+), and 7133 (5+). Each stage demonstrated significantly higher numbers of guttae than its preceding level except from 4+ to 5+ (p=0.30), consistent with the definition of 4+ as the highest level defined by presence of guttae. Higher levels of clinical grading were associated with larger ranges of guttae (p<0.01). A linear regression model resulted in a strong fit between RPA and Krachmer score (r=0.81). Conclusion In this largest study of RPA data and comparison with subjective clinical grading of FCD severity, RPA correlates strongly and demonstrates enhanced definition of severity at advanced stages of disease. PMID:26488628
C2 nerve root on magnetic resonance imaging of occipital neuralgia.
Yi, Minkyung; Lee, Joon Woo; Yeom, Jin S; Joe, Eugene; Hong, Sung Hwan; Lee, Guen Young; Kang, Heung Sik
2014-06-01
Review and grade the morphology of the C1-C2 neural foramina, from the MR images of patients who underwent C1-C2 spinal surgery, and determine the relationship with ON. To evaluate the feasibility of MRI for C1-C2 neural foramen evaluation with a new grading system and to correlate the C1-C2 neural foramen grade with ON. There have been no MRI studies of patients with and without ON in relation to C2 nerve root ganglion findings. Among the registry of 124 patients who underwent C1-C2 spinal surgery between July 2004 and May 2012 in Seoul National University Bundang Hospital, we enrolled 101 patients who had information about ON and a relevant preoperative cervical spine MR image. A total of 202 neural foramina were evaluated with our new C1-C2 neural foramen grading system (grade, 0-3) using consensus reading by 2 experienced radiologists who were blinded to the clinical information. The relationship between the C1-C2 grading system and ON was assessed using a χ test and Fisher exact test. Inter- and intraobserver reliability agreement was assessed using the κ statistic. All C1-C2 neural foramina were delineated on T2 parasagittal images. Among 202 C1-C2 neural foramina, grade zero was found in 49 foramina (24.3%), grade 1 in 95 (47.0%), grade 2 in 30 (14.9%), and grade 3 in 28 (13.9%). Grade 1 stenosis was most frequently noted. The grade 2 group had the most frequent prevalence of ON (43.3%), followed by grade 3 (35.7%), grade zero (30.6%), and grade 1 (29.5%). However, the relationship between the grade and ON was not statistically significant. Inter- and intraobserver agreements were substantially high. C1-C2 neural foramina can be depicted on MR image. However, the relationship between the new grading system for C1-C2 neural foramina and ON was not statistically significant. 4.
Bonny, S P F; Hocquette, J-F; Pethick, D W; Legrand, I; Wierzbicki, J; Allen, P; Farmer, L J; Polkinghorne, R J; Gardner, G E
2017-08-01
Quantifying consumer responses to beef across a broad range of demographics, nationalities and cooking methods is vitally important for any system evaluating beef eating quality. On the basis of previous work, it was expected that consumer scores would be highly accurate in determining quality grades for beef, thereby providing evidence that such a technique could be used to form the basis of and eating quality grading system for beef. Following the Australian MSA (Meat Standards Australia) testing protocols, over 19 000 consumers from Northern Ireland, Poland, Ireland, France and Australia tasted cooked beef samples, then allocated them to a quality grade; unsatisfactory, good-every-day, better-than-every-day and premium. The consumers also scored beef samples for tenderness, juiciness, flavour-liking and overall-liking. The beef was sourced from all countries involved in the study and cooked by four different cooking methods and to three different degrees of doneness, with each experimental group in the study consisting of a single cooking doneness within a cooking method for each country. For each experimental group, and for the data set as a whole, a linear discriminant function was calculated, using the four sensory scores which were used to predict the quality grade. This process was repeated using two conglomerate scores which are derived from weighting and combining the consumer sensory scores for tenderness, juiciness, flavour-liking and overall-liking, the original meat quality 4 score (oMQ4) (0.4, 0.1, 0.2, 0.3) and current meat quality 4 score (cMQ4) (0.3, 0.1, 0.3, 0.3). From the results of these analyses, the optimal weightings of the sensory scores to generate an 'ideal meat quality 4 score (MQ4)' for each country were calculated, and the MQ4 values that reflected the boundaries between the four quality grades were determined. The oMQ4 weightings were far more accurate in categorising European meat samples than the cMQ4 weightings, highlighting that tenderness is more important than flavour to the consumer when determining quality. The accuracy of the discriminant analysis to predict the consumer scored quality grades was similar across all consumer groups, 68%, and similar to previously reported values. These results demonstrate that this technique, as used in the MSA system, could be used to predict consumer assessment of beef eating quality and therefore to underpin a commercial eating quality guarantee for all European consumers.
ERIC Educational Resources Information Center
Bigot, Johann; Pichot, Nathalie; Teste, Benoit
2004-01-01
Numerous studies have demonstrated a decrease in the expression of internality in French sixth graders as compared to fifth graders. The present study examines normative clearsightedness in addition to internality across four French school grades (fourth to seventh). The results confirmed the sixth-grade drop in internality and showed that the…
The Impact of Framing Effect on Student Preferences for University Grading Systems
ERIC Educational Resources Information Center
Smith, Jeffrey K.; Smith, Lisa F.
2009-01-01
Kahneman and Tversky's (1979, 2000; Tversky & Kahneman, 1981) work in decision-making was applied to student preferences for grading practices. Undergraduate psychology students (n = 240) were randomly assigned to 1 of 3 framing conditions related to how a university course might be graded: a 100 point system, a percentage system, and an open…
A new MRI grading system for chondromalacia patellae.
Özgen, Ali; Taşdelen, Neslihan; Fırat, Zeynep
2017-04-01
Background Chondromalacia patellae is a very common disorder. Although magnetic resonance imaging (MRI) is widely used to investigate patellar cartilage lesions, there is no descriptive MRI-based grading system for chondromalacia patellae. Purpose To propose a new MRI grading system for chondromalacia patellae with corresponding high resolution images which might be useful in precisely reporting and comparing knee examinations in routine daily practice and used in predicting natural course and clinical outcome of the patellar cartilage lesions. Material and Methods High resolution fat-saturated proton density (FS PD) images in the axial plane with corresponding T2 mapping images were reviewed. A detailed MRI grading system covering the deficiencies of the existing gradings has been set and presented on these images. Two experienced observers blinded to clinical data examined 44 knee MR images and evaluated patellar cartilage changes according to the proposed grading system. Inter- and intra-rater validity testing using kappa statistics were calculated. Results A descriptive and detailed grading system with corresponding FS PD and T2 mapping images has been presented. Inter-rater agreement was 0.80 (95% confidence interval [CI], 0.71-0.89). Intra-rater agreements were 0.83 (95% CI, 0.74-0.91) for observer A and 0.79 (95% CI, 0.70-0.88) for observer B (k-values). Conclusion We present a new MRI grading system for chondromalacia patellae with corresponding images and good inter- and intra-rater agreement which might be useful in reporting and comparing knee MRI examinations in daily practice and may also have the potential for using more precisely predicting prognosis and clinical outcome of the patients.
ERIC Educational Resources Information Center
Cummings, Kelli D.; Stoolmiller, Michael L.; Baker, Scott K.; Fien, Hank; Kame'enui, Edward J.
2015-01-01
We present a method for data-based decision making at the school level using student achievement data. We demonstrate the potential of a national assessment database [i.e., the University of Oregon DIBELS Data System (DDS)] to provide comparative levels of school-level data on average student achievement gains. Through the DDS as a data source,…
Atkins, David; Eccles, Martin; Flottorp, Signe; Guyatt, Gordon H; Henry, David; Hill, Suzanne; Liberati, Alessandro; O'Connell, Dianne; Oxman, Andrew D; Phillips, Bob; Schünemann, Holger; Edejer, Tessa Tan-Torres; Vist, Gunn E; Williams, John W
2004-01-01
Background A number of approaches have been used to grade levels of evidence and the strength of recommendations. The use of many different approaches detracts from one of the main reasons for having explicit approaches: to concisely characterise and communicate this information so that it can easily be understood and thereby help people make well-informed decisions. Our objective was to critically appraise six prominent systems for grading levels of evidence and the strength of recommendations as a basis for agreeing on characteristics of a common, sensible approach to grading levels of evidence and the strength of recommendations. Methods Six prominent systems for grading levels of evidence and strength of recommendations were selected and someone familiar with each system prepared a description of each of these. Twelve assessors independently evaluated each system based on twelve criteria to assess the sensibility of the different approaches. Systems used by 51 organisations were compared with these six approaches. Results There was poor agreement about the sensibility of the six systems. Only one of the systems was suitable for all four types of questions we considered (effectiveness, harm, diagnosis and prognosis). None of the systems was considered usable for all of the target groups we considered (professionals, patients and policy makers). The raters found low reproducibility of judgements made using all six systems. Systems used by 51 organisations that sponsor clinical practice guidelines included a number of minor variations of the six systems that we critically appraised. Conclusions All of the currently used approaches to grading levels of evidence and the strength of recommendations have important shortcomings. PMID:15615589
Aviation Science Activities for Elementary Grades
DOT National Transportation Integrated Search
1983-01-01
This manual is meant to be a springboard toward your own ideas for : demonstrating concepts of the Air Age to your children, whatever the grade : level. Even little children can learn scientific principles through simple teaching aids; older pupils c...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shiraishi, Yutaka, E-mail: shiraishi@rad.med.keio.ac.jp; Hanada, Takashi; Ohashi, Toshio
2013-09-01
Purpose: To propose a novel parameter predicting rectal bleeding on the basis of generalized equivalent uniform doses (gEUD) after {sup 125}I prostate brachytherapy combined with external beam radiation therapy and to assess the predictive value of this parameter. Methods and Materials: To account for differences among radiation treatment modalities and fractionation schedules, rectal dose–volume histograms (DVHs) of 369 patients with localized prostate cancer undergoing combined therapy retrieved from corresponding treatment planning systems were converted to equivalent dose-based DVHs. The gEUDs for the rectum were calculated from these converted DVHs. The total gEUD (gEUD{sub sum}) was determined by a summation ofmore » the brachytherapy and external-beam radiation therapy components. Results: Thirty-eight patients (10.3%) developed grade 2+ rectal bleeding. The grade 2+ rectal bleeding rate increased as the gEUD{sub sum} increased: 2.0% (2 of 102 patients) for <70 Gy, 10.3% (15 of 145 patients) for 70-80 Gy, 15.8% (12 of 76 patients) for 80-90 Gy, and 19.6% (9 of 46 patients) for >90 Gy (P=.002). Multivariate analysis identified age (P=.024) and gEUD{sub sum} (P=.000) as risk factors for grade 2+ rectal bleeding. Conclusions: Our results demonstrate gEUD to be a potential predictive factor for grade 2+ late rectal bleeding after combined therapy for prostate cancer.« less
Assessment of student learning with hypermedia tools in first-year college chemistry
NASA Astrophysics Data System (ADS)
Skov, Neil Martin
Learning chemistry is difficult for some students. In response to this difficulty, many educators argue that hypermedia technology can promote learning of abstract chemistry concepts. This research assesses learning outcomes and use patterns exhibited by first-year college general chemistry students using an instructional hypermedia system called Seeing Through Chemistry (STC) as part of their first course. STC was designed to help students with inadequate preparation for college chemistry. The assessment answers two questions: (a) do students learn from instructional hypermedia, and (b) what kind of students benefit from this medium? This non-experimental, quantitative research involved 82 student volunteers in their first college chemistry course. Data include SAT scores, high school science and mathematics grades, career orientation, chemistry placement score, motivation, laboratory and lecture section enrollment, and chemistry course grade. The investigation requires two specialized assessment tools: a measure of conceptual understanding of acids and bases, and a measure of cognitive engagement with hypermedia. Data analysis methods include two causal path models to examine hypermedia use and learning outcomes: one showing STC's effect on overall chemistry course performance, and the other demonstrating the effect of a single STC module on students' conceptual knowledge of acids and bases. Though there is no significant effect on course grade, the second analysis shows statistically significant learning from students' work with instructional hypermedia. Both causal models demonstrate that students with poorer preparation for college chemistry used STC more than students with better preparation, which matches the designers' intent. Some better prepared students were relatively more motivated to use the hypermedia system. Other findings show positive effects of high school science and college laboratory coursework on concept learning. This research informs the field of hypermedia design. Since STC's developers used particular parameters to guide their design, the medium's positive effect on learning indirectly supports the underlying design parameters. This research also demonstrates an effective method for assessing hypermedia learning in large course settings. In addition, the study exhibits a new tool for investigating conceptual understandings of large numbers of students, and a new way to measure cognitive engagement of students using instructional hypermedia.
ERIC Educational Resources Information Center
Felder, Nathaniel L.
The grading system at the University of North Carolina at Asheville before fall 1978 provided four designations: H (honors); G (good or well above average); P (pass or satisfactory); and F (failure). This range does not provide a grade for unsatisfactory but passing work. It was suspected that this led teachers to give "average" grades…
Vázquez García, M J; Vargas Camaño, M E; Olalde Carmona, R
2000-01-01
Systemic Lupus Eritematosus is an autoimmune disease, the incidence in pediatric poblation in about 5%, and until 90% develop nephropathy. Included patients with lupic nephropathy grade IV (OMS) ages between 0 and 16 years old, multitreated, who administrated PTX. We take samples before treatment, during, and 4 month after, evaluating renal function and hepatic function. For female, tow male, promedium age 14.1 years old. Poteinuria get a significative p = 0.0012; hematuria was lowering its levels, While immune circulating complex, get too a significative p = 0.0050. In creatinine inverse showed an important modification of its pending. This results demonstrates, that PTX in nephritis lupic patients, helps to brake the habitual deterioration in renal function. Includes more patients for a long time of treatment, we'll get better results than this.
Liver transplantation for hepatocellular carcinoma: a proposal of a prognostic scoring system.
Iwatsuki, S; Dvorchik, I; Marsh, J W; Madariaga, J R; Carr, B; Fung, J J; Starzl, T E
2000-10-01
The current staging system of hepatocellular carcinoma established by the International Union Against Cancer and the American Joint Committee on Cancer does not necessarily predict the outcomes after hepatic resection or transplantation. Various clinical and pathologic risk factors for tumor recurrence were examined on 344 consecutive patients who received hepatic transplantation in the presence of nonfibrolamellar hepatocellular carcinoma to establish a reliable risk scoring system. Multivariate analysis identified three factors as independently significant poor prognosticators: 1) bilobarly distributed tumors, 2) size of the greatest tumor (2 to 5 cm and > 5 cm), and 3) vascular invasion (microscopic and macroscopic). Prognostic risk score (PRS) of each patient was calculated from the relative risks of multivariate analysis. The patients were grouped into five grades of tumor recurrence risk: grade 1: PRS = 0 to < 7.5; grade 2: PRS = 7.5 to < or = 11.0; grade 3: PRS > 11.0 to 15.0; grade 4: PRS > or = 15.0; and grade 5: positive node, metastasis, or margin. The proposed PRS system correlated extremely well with tumor-free survival after liver transplantation (100%, 61%, 40%, 5%, and 0%, from grades 1 to 5, respectively, at 5 years), but current pTNM staging did not. 1) Patients with grades 1 and 2 are effectively treated with liver transplantation, 2) patients with grades 4 and 5 are poor candidates for liver transplantation, and 3) patients with grade 1 do not benefit from adjuvant chemotherapy.
A 3-tier classification of cerebral arteriovenous malformations. Clinical article.
Spetzler, Robert F; Ponce, Francisco A
2011-03-01
The authors propose a 3-tier classification for cerebral arteriovenous malformations (AVMs). The classification is based on the original 5-tier Spetzler-Martin grading system, and reflects the treatment paradigm for these lesions. The implications of this modification in the literature are explored. Class A combines Grades I and II AVMs, Class B are Grade III AVMs, and Class C combines Grades IV and V AVMs. Recommended management is surgery for Class A AVMs, multimodality treatment for Class B, and observation for Class C, with exceptions to the latter including recurrent hemorrhages and progressive neurological deficits. To evaluate whether combining grades is warranted from the perspective of surgical outcomes, the 3-tier system was applied to 1476 patients from 7 surgical series in which results were stratified according to Spetzler-Martin grades. Pairwise comparisons of individual Spetzler-Martin grades in the series analyzed showed the fewest significant differences (p < 0.05) in outcomes between Grades I and II AVMs and between Grades IV and V AVMs. In the pooled data analysis, significant differences in outcomes were found between all grades except IV and V (p = 0.38), and the lowest relative risks were found between Grades I and II (1.066) and between Grades IV and V (1.095). Using the pooled data, the predictive accuracies for surgical outcomes of the 5-tier and 3-tier systems were equivalent (receiver operating characteristic curve area 0.711 and 0.713, respectively). Combining Grades I and II AVMs and combining Grades IV and V AVMs is justified in part because the differences in surgical results between these respective pairs are small. The proposed 3-tier classification of AVMs offers simplification of the Spetzler-Martin system, provides a guide to treatment, and is predictive of outcome. The revised classification not only simplifies treatment recommendations; by placing patients into 3 as opposed to 5 groups, statistical power is markedly increased for series comparisons.
Fluorescence lifetime spectroscopy for guided therapy of brain tumors.
Butte, Pramod V; Mamelak, Adam N; Nuno, Miriam; Bannykh, Serguei I; Black, Keith L; Marcu, Laura
2011-01-01
This study evaluates the potential of time-resolved laser induced fluorescence spectroscopy (TR-LIFS) as intra-operative tool for the delineation of brain tumor from normal brain. Forty two patients undergoing glioma (WHO grade I-IV) surgery were enrolled in this study. A TR-LIFS prototype apparatus (gated detection, fast digitizer) was used to induce in-vivo fluorescence using a pulsed N2 laser (337 nm excitation, 0.7 ns pulse width) and to record the time-resolved spectrum (360-550 nm range, 10 nm interval). The sites of TR-LIFS measurement were validated by conventional histopathology (H&E staining). Parameters derived from the TR-LIFS data including intensity values and time-resolved intensity decay features (average fluorescence lifetime and Laguerre coefficients values) were used for tissue characterization and classification. 71 areas of tumor and normal brain were analyzed. Several parameters allowed for the differentiation of distinct tissue types. For example, normal cortex (N=35) and normal white matter (N=12) exhibit a longer-lasting fluorescence emission at 390 nm (τ390=2.12±0.10 ns) when compared with 460 nm (τ460=1.16±0.08 ns). High grade glioma (grades III and IV) samples (N=17) demonstrate emission peaks at 460 nm, with large variation at 390 nm while low grade glioma (I and II) samples (N=7) demonstrated a peak fluorescence emission at 460 nm. A linear discriminant algorithm allowed for the classification of low-grade gliomas with 100% sensitivity and 98% specificity. High-grade glioma demonstrated a high degree of heterogeneity thus reducing the discrimination accuracy of these tumors to 47% sensitivity and 94% specificity. Current findings demonstrate that TR-LIFS holds the potential to diagnose brain tumors intra-operatively and to provide a valuable tool for aiding the neurosurgeon-neuropathologist team in to rapidly distinguish between tumor and normal brain during surgery. Copyright © 2010 Elsevier Inc. All rights reserved.
Hafez, Ahmad; Koroknay-Pál, Päivi; Oulasvirta, Elias; Elseoud, Ahmed Abou; Lawton, Michael T; Niemelä, Mika; Laakso, Aki
2018-05-04
A supplementary grading scale (Supplemented Spetzler-Martin grade, Supp-SM) was introduced in 2010 as a refinement of the SM system to improve preoperative risk prediction of brain arteriovenous malformations (AVMs). To determine the ability to predict surgical outcomes using the Supp-SM grading scale. This retrospective study was conducted on 200 patients admitted to the Helsinki University Hospital between 2000 and 2014. The validity of the Supp-SM and SM grading systems was compared using the area under the receiver operating characteristic (AUROC) curves, with respect to the change between preoperative and early (3-4 mo) as well as final postoperative modified Rankin Scale (mRS) scores. The performance of the Supp-SM was superior to that of the SM grading scale in the early follow-up (3-4 mo): AUROC = 0.57 (95% confidence interval [CI]: 0.49-0.65) for SM and AUROC = 0.67 (95% CI: 0.60-0.75) for Supp-SM. The Supp-SM performance continued improving over SM at the late follow-up: AUROC = 0.63 (95% CI: 0.55-0.71) for SM and AUROC = 0.70 (95% CI: 0.62-0.77) for Supp-SM. The perforating artery supply, which is not part of either grading system, plays an important role in the early follow-up outcome (P = .008; odds ratio: 2.95; 95% CI: 1.32-6.55) and in the late follow-up outcome (P < .001; odds ratio: 5.89; 95% CI: 2.49-13.91). The Supp-SM grading system improves the outcome prediction accuracy and is a feasible alternative to the SMS, even for series with higher proportion of high-grade AVMs. However, perforators play important role on the outcome.
Semiconductor-metal graded-index composite thin films for infrared applications
NASA Technical Reports Server (NTRS)
Lamb, James L.; Nagendra, C. L.
1994-01-01
Theoretical/experimental studies have been carried out on germanium:silver (Ge:Ag) graded-index composite thin films which demonstrate that graded coatings, consisting of varied concentrations of Ag with respect to the Ge film thickness, exhibit different optical properties ranging from selective infrared (IR) reflectance to broadband IR absorptance. The graded coatings have been produced by dc magnetron cosputtering of Ge and Ag and the spectral properties are found to be stable against temperature. The coatings have been applied to an infrared tunnel sensor (micro-Golay cell) to improve the device performance.
ERIC Educational Resources Information Center
Karran, Terence
2005-01-01
This article assesses the impact of the Bologna Process on the grading schemes of EU member countries. In light of some problems regarding the implementation of the European Credit Transfer system (ECTS), the author proposes further reforms and offers some elements of a unified grading system for European higher education. The author explores the…
Self-imaging of partially coherent light in graded-index media.
Ponomarenko, Sergey A
2015-02-15
We demonstrate that partially coherent light beams of arbitrary intensity and spectral degree of coherence profiles can self-image in linear graded-index media. The results can be applicable to imaging with noisy spatial or temporal light sources.
Ueno, Hideki; Hase, Kazuo; Hashiguchi, Yojiro; Shimazaki, Hideyuki; Tanaka, Masafumi; Miyake, Ohki; Masaki, Tadahiko; Shimada, Yoshifumi; Kinugasa, Yusuke; Mori, Yoshiyuki; Kishimoto, Mitsuo; Kameoka, Shingo; Sato, Yu; Matsuda, Keiji; Nakadoi, Koichi; Shinto, Eiji; Nakamura, Takahiro; Sugihara, Kenichi
2014-02-01
The study aimed to determine the value of a novel site-specific grading system based on quantifying poorly differentiated clusters (PDC; Grade(PDC)) in colorectal cancer (CRC). A multicenter pathologic review involving 12 institutions was performed on 3243 CRC cases (stage I, 583; II, 1331; III, 1329). Cancer clusters of ≥5 cancer cells and lacking a gland-like structure (PDCs) were counted under a ×20 objective lens in a field containing the maximum clusters. Tumors with <5, 5 to 9, and ≥10 PDCs were classified as grades G1, G2, and G3, respectively. According to Grade(PDC), 1594, 1005, and 644 tumors were classified as G1, G2, and G3 and had 5-year recurrence-free survival rates of 91.6%, 75.4%, and 59.6%, respectively (P<0.0001). Multivariate analysis showed that Grade exerted an influence on prognostic outcome independently of TNM staging; approximately 20% and 46% of stage I and II patients, respectively, were selected by Grade(PDC) as a population whose survival estimate was comparable to or even worse than that of stage III patients. Grade(PDC) surpassed TNM staging in the ability to stratify patients by recurrence-free survival (Akaike information criterion, 2915.6 vs. 2994.0) and had a higher prognostic value than American Joint Committee on Cancer (AJCC) grading (Grade(AJCC)) at all stages. Regarding judgment reproducibility of grading tumors, weighted κ among the 12 institutions was 0.40 for Grade(AJCC) and 0.52 for Grade(PDC). Grade(PDC) has a robust prognostic power and promises to be of sufficient clinical value to merit implementation as a site-specific grading system in CRC.
A USNRC perspective on the use of commercial-off-shelf software (COTS) in advanced reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, J.C.
1997-12-01
The use of commercially available digital computer systems and components in safety critical systems (nuclear power plant, military, and commercial applications) is increasing rapidly. While this paper focuses on the software aspects of the application most of these continents are applicable to the hardware aspects as well. Commercial dedication (the process of assuring that a commercial grade item will perform its intended safety function) has demonstrated benefits in cost savings and a wide base of user experience, however, care must be taken to avoid difficulties with some aspects of the dedication process such as access to vendor development information, configurationmore » management long term support, and system integration.« less
Automated grading system for evaluation of ocular redness associated with dry eye.
Rodriguez, John D; Johnston, Patrick R; Ousler, George W; Smith, Lisa M; Abelson, Mark B
2013-01-01
We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye. To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used. Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0-4 (in 0.5 increments) dry eye redness (Ora Calibra™ Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as "horizontality"). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R - 0.83G - 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset. The agreement (both Pearson's and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a given image has 100% repeatability and zero variability from session to session. This objective means of grading ocular redness in a unified fashion has potential significance as a new clinical endpoint. In comparisons between computer and investigator, computer grading proved to be more reliable than another investigator using the OCDER scale. The best fitting model based on the present sample, and usable for future studies, was [Formula: see text] is the predicted investigator grade, and [Formula: see text] and [Formula: see text] are logarithmic transformations of the computer calculated parameters COM-Hor and COM-Red. Considering the superior repeatability, computer automated grading might be preferable to investigator grading in multicentered dry eye studies in which the subtle differences in redness incurred by treatment have been historically difficult to define.
Effective use of e-grading in the dental simulation clinic.
Morrow, Jay A; Pulido, M Teresa; Smith, P Bradford; McDaniel, Thomas F; Willcox, Austin B
2014-06-01
The purpose of this article is to describe the development and implementation of a grading software system, accessible from any platform, that engages today's generation of students and replaces paper grading. Set up at one U.S. dental school in an all-access, anytime (24/7) web-based program accessed through tablets, the software allows for a comparison between students' self-grading and instructor grading. This comparison facilitates student-faculty interaction, promoting discussion and student learning. The software can also be used for practical examination grading in which blinded grading between instructors is possible. The data gathered can produce descriptive reports students can draw upon to encourage self-learning and guided learning, propelling students to a better understanding of critical principles as they progress through multiple psychomotor skill sets. Other reports generated by the software allow for instructor calibration, exporting of grades directly into the university grading report system, and visual analysis of trends within each class. In a post-course survey, students (56 percent response rate) and faculty (79 percent response rate) agreed that the electronic grading was more efficient and allowed more time for faculty-student interaction than the previous grading system, thus creating an environment more conducive to learning. Overall, the software has improved students' perception of enhanced kinetic skills, while facilitating administration of preclinical projects and practical examinations.
Philip A. Araman; Janice K. Wiedenbeck
1995-01-01
Automated lumber grading and yield optimization using computer controlled saws will be plausible for hardwoods if and when lumber scanning systems can reliably identify all defects by type. Existing computer programs could then be used to grade the lumber, identify the best cut-up solution, and control the sawing machines. The potential value of a scanning grading...
NASA Astrophysics Data System (ADS)
Bradbury-Bailey, Mary
With the implementation of No Child Left Behind came a wave of educational reform intended for those working with student populations whose academic performance seemed to indicate an alienation from the educational process. Central to these reforms was the implementation of standards-based instruction and their accompanying standardized assessments; however, in one area reform seemed nonexistent---the teacher's gradebook. (Erickson, 2010, Marzano, 2006; Scriffiny, 2008). Given the link between the grading process and achievement motivation, Ames (1992) suggested the use of practices that promote mastery goal orientation. The purpose of this study was to examine the impact of standards-based grading system as a factor contributing to mastery goal orientation on the academic performance of urban African American students. To determine the degree of impact, this study first compared the course content averages and End-of-Course-Test (EOCT) scores for science classes using a traditional grading system to those using a standards-based grading system by employing an Analysis of Covariance (ANCOVA). While there was an increase in all grading areas, two showed a significant difference---the Physical Science course content average (p = 0.024) and ix the Biology EOCT scores (p = 0.0876). These gains suggest that standards-based grading can have a positive impact on the academic performance of African American students. Secondly, this study examined the correlation between the course content averages and the EOCT scores for both the traditional and standards-based grading system; for both Physical Science and Biology, there was a stronger correlation between these two scores for the standards-based grading system.
ERIC Educational Resources Information Center
Joint Council on Economic Education, New York, NY.
This guide contains concept based lessons and activities in economics for use with students in grades 4-6. One component of a two-part publication, the guide demonstrates how the conceptual structure of the economics discipline presented in the first publication (ED 148 648) can be used to help students at the intermediate grade level make more…
ERIC Educational Resources Information Center
Lovett, Maureen W.; Frijters, Jan C.; Wolf, Maryanne; Steinbach, Karen A.; Sevcik, Rose A.; Morris, Robin D.
2017-01-01
Across multiple schools and sites, the impact of grade-at-intervention was evaluated for children at risk or meeting criteria for reading disabilities. A multiple-component reading intervention with demonstrated efficacy was offered to small groups of children in 1st, 2nd, or 3rd grade. In a quasi-experimental design, 172 children received the…
Kieffer, Michael J; Marinell, William H; Neugebauer, Sabina Rak
2014-12-01
In this longitudinal study, we investigated the use of attendance during middle school as a behavioral indicator of engagement to predict whether students are on track toward high school graduation. We used administrative data from four cohorts of students in New York City schools (N=303,845) to (a) explore patterns of change in attendance between Grades 4 and 8 and (b) determine the extent to which changes in attendance between Grades 4 and 8 predict which students are on track in Grade 9 for going on to graduate from high school. Results of latent growth modeling indicated that students demonstrate the most substantial declines in attendance during Grade 8 and that attendance changes are most variable in this year, with some students demonstrating much more dramatic declines than others. In addition, these changes in attendance were robust predictors of whether students were on track for high school graduation. To identify students who are at risk for not graduating for the purposes of providing appropriate interventions, educators should pay attention to their commonly collected data on attendance rates as a behavioral indicator of engagement. Copyright © 2014 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
Low-grade serous ovarian cancer: A review.
Kaldawy, Anis; Segev, Yakir; Lavie, Ofer; Auslender, Ron; Sopik, Victoria; Narod, Steven A
2016-11-01
Epithelial ovarian cancers can be divided into the more common, aggressive type II cancers and the less common, slow-growing type I cancers. Under this model, serous ovarian carcinomas can be subdivided into high-grade (type II) and low-grade (type I) tumours. The two-tier system for grading serous ovarian carcinomas is superior to more detailed grading systems in terms of predicting survival. Low-grade serous carcinomas typically present in young women and have a relatively good prognosis, despite being resistant to chemotherapy. Low-grade serous cancers have a high prevalence of KRAS and BRAF mutations, but a low prevalence of TP53 mutations (which are characteristic of high-grade serous cancers). Among women with low-grade serous ovarian cancer, the presence of a KRAS/BRAF mutation is a favorable prognostic factor. Studies of the mitogen-activated protein kinase (MAPK) inhibitor in low-grade serous ovarian cancer suggest that identifying MAPK mutations might eventually be useful in guiding treatment. Copyright © 2016 Elsevier Inc. All rights reserved.
Student Attitudes Toward Grades and Grading Practices.
ERIC Educational Resources Information Center
Stallings, William M.; Leslie, Elwood K.
The result of a study designed to assess student attitudes toward grading practices are discussed. Questionnaire responses of 3439 students in three institutions were tabulated. Responses were generally negative toward conventional grading systems. (MS)
Tan, Anna C S; Wang, Jie Jin; Lamoureux, Ecosse L; Wong, Wanling; Mitchell, Paul; Li, Jialiang; Tan, Ava Grace; Wong, Tien Y
2011-08-01
Cataract is the major cause of blindness worldwide yet there is no consensus on its assessment and definition. This study compares age-related cataract prevalence derived from two commonly used methods: clinical assessment using the Lens Opacity Classification System (LOCS III) and photographic grading using the Wisconsin Cataract Grading System (Wisconsin System). The Singapore Malay Eye Study is a population-based study of 3,280 Singapore Malays aged 40-80 years. Presence of nuclear, cortical and posterior sub-capsular cataract was assessed clinically during slit-lamp examination using LOCS III, and via slit-lamp and retro-illumination photographic grading using the Wisconsin System. Analyses were conducted to determine agreement in cataract prevalence estimates between the two grading Systems and approaches. Poor agreement was found between severity levels of the two grading scales for all three cataract types. Using currently accepted cut-offs to define nuclear (≥ 4 on both LOCS III and Wisconsin System), cortical (≥ 2 in LOCS III, ≥ 25% in Wisconsin) and PSC (≥ 2 in LOCS III, ≥ 5 % in Wisconsin) cataract, the LOCS III overestimated the prevalence of significant cataract as compared to the Wisconsin System, with nuclear cataract prevalence, 27.5% (LOCS III) versus 17.0% (Wisconsin System), cortical cataract prevalence, 27.9% versus 7.0% and posterior sub-capsular cataract prevalence, 7.8% versus 5.1%. The prevalence of cataract in a population varies substantially by measurement methods, with systematically different estimates found using the two most frequent cataract grading systems. This study re-emphasizes the need for global standards to assess and define cataract for epidemiologic and clinical studies.
NASA Astrophysics Data System (ADS)
Thiébaut, E.; Goupil, C.; Pesty, F.; D'Angelo, Y.; Guegan, G.; Lecoeur, P.
2017-12-01
Increasing the maximum cooling effect of a Peltier cooler can be achieved through material and device design. The use of inhomogeneous, functionally graded materials may be adopted in order to increase maximum cooling without improvement of the Z T (figure of merit); however, these systems are usually based on the assumption that the local optimization of the Z T is the suitable criterion to increase thermoelectric performance. We solve the heat equation in a graded material and perform both analytical and numerical analysis of a graded Peltier cooler. We find a local criterion that we use to assess the possible improvement of graded materials for thermoelectric cooling. A fair improvement of the cooling effect (up to 36%) is predicted for semiconductor materials, and the best graded system for cooling is described. The influence of the equation of state of the electronic gas of the material is discussed, and the difference in term of entropy production between the graded and the classical system is also described.
X-ray Reciprocal Space Mapping of Graded Al x Ga1 - x N Films and Nanowires.
Stanchu, Hryhorii V; Kuchuk, Andrian V; Kladko, Vasyl P; Ware, Morgan E; Mazur, Yuriy I; Zytkiewicz, Zbigniew R; Belyaev, Alexander E; Salamo, Gregory J
2016-12-01
The depth distribution of strain and composition in graded Al x Ga1 - x N films and nanowires (NWs) are studied theoretically using the kinematical theory of X-ray diffraction. By calculating [Formula: see text] reciprocal space maps (RSMs), we demonstrate significant differences in the intensity distributions from graded Al x Ga1 - x N films and NWs. We attribute these differences to relaxation of the substrate-induced strain on the NWs free side walls. Finally, we demonstrate that the developed X-ray reciprocal space map model allows for reliable depth profiles of strain and Al composition determination in both Al x Ga1 - x N films and NWs.
Yuh, Bertram E; Nazmy, Michael; Ruel, Nora H; Jankowski, Jason T; Menchaca, Anita R; Torrey, Robert R; Linehan, Jennifer A; Lau, Clayton S; Chan, Kevin G; Wilson, Timothy G
2012-11-01
Comprehensive and standardized reporting of adverse events after robot-assisted radical cystectomy (RARC) and urinary diversion for bladder cancer is necessary to evaluate the magnitude of morbidity for this complex operation. To accurately identify and assess postoperative morbidity after RARC using a standardized reporting system. A total of 241 consecutive patients underwent RARC, extended pelvic lymph node dissection, and urinary diversion between 2003 and 2011. In all, 196 patients consented to a prospective database, and they are the subject of this report. Continent diversions were performed in 68% of cases. All complications within 90 d of surgery were defined and categorized by a five-grade and 10-domain modification of the Clavien system. Univariable and multivariable logistic regression analyses were used to identify predictors of complications. Grade 1-2 complications were categorized as minor, and grade 3-5 complications were categorized as major. All blood transfusions were recorded as grade ≥2. Eighty percent of patients (156 of 196 patients) experienced a complication of any grade ≤90 d after surgery. A total of 475 adverse events (113 major) were recorded, with 365 adverse events (77%) occurring ≤30 d after surgery. Sixty-eight patients (35%) experienced a major complication within the first 90 d. Other than blood transfusions given (86 patients [43.9%]), infectious, gastrointestinal, and procedural complications were the most common, at 16.2%, 14.1%, and 10.3%, respectively. Age, comorbidity, preoperative hematocrit, estimated blood loss, and length of surgery were predictive of a complication of any grade, while comorbidity, preoperative hematocrit, and orthotopic diversion were predictive of major complications. The 90-d mortality rate was 4.1%. The main limitation is lack of a control group. Analysis of postoperative morbidity following RARC demonstrates a considerable complication rate, though the rate is comparable to contemporary open series that followed similar reporting guidelines. This finding reinforces the need for complete and standardized reporting when evaluating surgical techniques and comparing published series. Copyright © 2012 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Liu, Ning; Gan, Weidong; Qu, Feng; Wang, Zhen; Zhuang, Wenyuan; Agizamhan, Sezim; Xu, Linfeng; Yin, Juanjuan; Guo, Hongqian; Li, Dongmei
2018-04-01
The Fuhrman and World Health Organization/International Society of Urological Pathology (WHO/ISUP) grading systems are widely used to predict survival for patients with conventional renal cell carcinoma. To determine the validity of nuclear grading systems (both the Fuhrman and the WHO/ISUP) and the individual components of the Fuhrman grading system in predicting the prognosis of Xp11.2 translocation renal cell carcinoma (Xp11.2 tRCC), we identified and followed up 47 patients with Xp11.2 tRCC in our center from January 2007 to June 2017. The Fuhrman and WHO/ISUP grading was reassigned by two pathologists. Nuclear size and shape were determined for each case based on the greatest degree of nuclear pleomorphism using image analysis software. Univariate and multivariate analyses were performed to evaluate the capacity of the grading systems and nuclear parameters to predict overall survival and progression-free survival. On univariate Cox regression analysis, the parameters of nuclear size were associated significantly with overall survival and progression-free survival, whereas the grading systems and the parameters of nuclear shape failed to reach a significant correlation. On multivariate analysis, however, none of the parameters was associated independently with survival. Our findings indicate that neither the Fuhrman nor the WHO/ISUP grading system is applicable to Xp11.2 tRCC. The assessment of nuclear size instead may be novel outcome predictors for patients with Xp11.2 tRCC. Copyright © 2018 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Smith, Shirley Mccraw
2003-06-01
The purpose of this research was to investigate students' understanding of interdependency across grade levels. Interdependency concepts selected for this study included food chains, pollination, and seed dispersal. Children's everyday concepts and scientific concepts across grade levels represented the focus of conceptual understanding. The researcher interviewed a total of 24 students across grade levels, six students each from grades 3, 7, and 10, and 6 college students. Data were collected by means of interviews and card sorts. A constructivist theoretical framework formed the groundwork for presenting the focus of this study and for interpreting the results of the interview data. Results were analyzed on the basis of identifying student responses to interview questions as either everyday concepts or as scientific concepts, along with transition through the zone of proximal development (ZPD) by mediation, as developed by Vygotsky. Results revealed that children across grade levels vary in their everyday and scientific understanding of the three interdependency concepts. Results for seed dispersal showed little evidence of understanding for grade 3, that is, seed dispersal was not within the zone of proximal development (ZPD) for grade 3 students. Students in grades 7 and 10 showed a developing transition within the zone of proximal development from everyday to scientific understanding, and college students demonstrated scientific understanding of seed dispersal. For pollination and food chains, results showed that grades 3, 7, and 10 were in transition from everyday to scientific understanding, and all college students demonstrated scientific understanding. The seed dispersal concept proved more complex than pollination and food chains. The findings of this study have implications for classroom teachers. By understanding the dynamic nature of the ZPD continuum for students, teachers can plan instruction to meet the needs of each student.
Aryankhesal, Aidin; Sheldon, Trevor A; Mannion, Russell; Mahdipour, Saeade
2015-07-01
Performance measurement systems are increasingly used to reward and improve provider performance. However, such initiatives may also inadvertently induce a range of unintended and dysfunctional side-effects. This study explores the unintended and adverse consequences induced by the Iranian national hospital grading programme, which incorporates financial incentives for meeting nationally defined standards. We interviewed key informants across four key groups with a legitimate interest in healthcare performance: four purposively selected hospitals; four health insurance organizations; the Iranian hospital accreditation body; and one grading agency. The transcribed interviews and field notes were analysed thematically, and subsequently, member checking was conducted. Seven dysfunctional consequences were identified: misrepresentation of data by hospitals; increased anxiety and stress among hospital employees; tunnel vision; financial pressures on poorly graded hospitals; incentives to purchase unnecessary equipment; erosion of public trust; and restricting access to hospital services by patients. These were caused by the way the grading system was implemented: poor standards of audit; the way in which the audit process was conducted; and the timing of audits. The pay for performance element of the grading system and the focus on structural aspects in the standards made improvement in grading particularly difficult for those hospitals that had been assessed as under-performing. Although the Iranian hospital grading system has resulted in a significant increase in the adoption of national standards, it has nevertheless induced a range of perverse outcomes. To mitigate these requires further refinement and recalibration of the system. © The Author(s) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Truong, Minh Tam, E-mail: mitruong@bu.edu; Department of Radiology, Boston Medical Center and Boston University School of Medicine, Boston, MA; Lee, Richard
2012-02-01
Purpose: To measure changes in perfusion of the pharyngeal constrictor muscles (PCM) using CT perfusion (CTP) imaging during a course of definitive radiotherapy (RT) in head-and-neck cancer (HNC) patients and correlate with dysphagia outcome after RT. Methods and Materials: Fifteen HNC patients underwent CTP imaging of the PCM at baseline and Weeks 2, 4, and 6 during RT and 6 weeks after RT. Blood flow and blood volume were measured in the PCM, and percentage change from baseline scan was determined. A single physician-based assessment of dysphagia was performed every 3 months after RT using the Common Terminology Criteria formore » Adverse Events, version 3.0 grading system. Results: With a median follow-up of 28 months (range, 6-44 months), Grade 3 dysphagia was present in 7 of 15 patients, and 8 patients experienced Grade 0-2 dysphagia. The CTP parameters at Week 2 of RT demonstrated an increase in mean PCM blood flow of 161.9% vs. 12.3% (p = 0.007) and an increase in mean PCM blood volume of 96.6% vs. 8.7% (p = 0.039) in patients with 6-month post-RT Grade 3 dysphagia and Grade 0-2 dysphagia, respectively. On multivariate analysis, when adjusting for smoking history, tumor volume, and baseline dysphagia status, an increase in blood flow in the second week of RT was significant for 3- and 6-month Grade 3 dysphagia (p < 0.05). Conclusions: Perfusion changes in the PCM during Week 2 of RT in the PCM may predict the severity of dysphagia after HNC RT.« less
Increasing Academic Skills of Students with Autism Using Fifth Grade Peers as Tutors.
ERIC Educational Resources Information Center
Kamps, Debra; And Others
1989-01-01
Nonhandicapped fifth-grade students conducted tutoring sessions in math, language, and reading for two elementary-aged children with autism. Results demonstrated that normal peers could effectively increase academic behaviors of autistic students through tutoring activities. (Author/JDD)
Development and application of a statistical quality assessment method for dense-graded mixes.
DOT National Transportation Integrated Search
2004-08-01
This report describes the development of the statistical quality assessment method and the procedure for mapping the measures obtained from the quality assessment method to a composite pay factor. The application to dense-graded mixes is demonstrated...
Schuh, Fernando; Biazús, Jorge Villanova; Resetkova, Erika; Benfica, Camila Zanella; Ventura, Alessandra de Freitas; Uchoa, Diego; Graudenz, Márcia; Edelweiss, Maria Isabel Albano
2015-07-10
Histopathological grading diagnosis of ductal carcinoma in situ (DCIS) of the breast may be very difficult even for experts, and it is important for therapeutic decisions. The challenge may be due to the inaccurate and/or subjective application of the diagnosis criteria. The aim of this study was to investigate the intra-observer agreement between a traditional method and a developed web-based questionnaire for scoring breast DCIS. A cross-sectional study was carried out to evaluate the diagnostic agreement of an electronic questionnaire and its point scoring system with the subjective reading of digital images for 3 different DCIS grading systems: Holland, Van Nuys and modified Black nuclear grade system. Three pathologists analyzed the same set of digitized images from 43 DCIS cases using two different web-based programs. In the first phase, they accessed a website with a newly created questionnaire and scoring system developed to allow the determination of the histological grade of the cases. After at least 6 months, the pathologists read again the same images, but without the help of the questionnaire, indicating subjectively the diagnoses. The intra-observer agreement analysis was employed to validate this innovative web-based survey. Overall, diagnostic reproducibility was similar for all histologic grading classification systems, with kappa values of 0.57 ± 0.10, 0.67 ± 0.09 and 0.67 ± 0.09 for Holland, Van Nuys classification and modified Black nuclear grade system respectively. Only two 2-step diagnostic disagreements were found, one for Holland and another for Van Nuys. Both cases were superestimated by the web-based survey. The diagnostic agreement between the web-based questionnaire and a traditional method, both using digital images, is moderate to good for Holland, Van Nuys and modified Black nuclear grade system. The use of a scoring point system does not appear to pose a major risk of presenting large (2-step) diagnostic disagreements. These findings indicate that the use of this point scoring system in this web-based survey to grade objectively DCIS lesions is a useful diagnostic tool.
Carleton, Neil M; Zhu, Guangjing; Gorbounov, Mikhail; Miller, M Craig; Pienta, Kenneth J; Resar, Linda M S; Veltri, Robert W
2018-05-01
There are few tissue-based biomarkers that can accurately predict prostate cancer (PCa) progression and aggressiveness. We sought to evaluate the clinical utility of prostate and breast overexpressed 1 (PBOV1) as a potential PCa biomarker. Patient tumor samples were designated by Grade Groups using the 2014 Gleason grading system. Primary radical prostatectomy tumors were obtained from 48 patients and evaluated for PBOV1 levels using Western blot analysis in matched cancer and benign cancer-adjacent regions. Immunohistochemical evaluation of PBOV1 was subsequently performed in 80 cancer and 80 benign cancer-adjacent patient samples across two tissue microarrays (TMAs) to verify protein levels in epithelial tissue and to assess correlation between PBOV1 proteins and nuclear architectural changes in PCa cells. Digital histomorphometric analysis was used to track 22 parameters that characterized nuclear changes in PBOV1-stained cells. Using a training and test set for validation, multivariate logistic regression (MLR) models were used to identify significant nuclear parameters that distinguish Grade Group 3 and above PCa from Grade Group 1 and 2 PCa regions. PBOV1 protein levels were increased in tumors from Grade Group 3 and above (GS 4 + 3 and ≥ 8) regions versus Grade Groups 1 and 2 (GS 3 + 3 and 3 + 4) regions (P = 0.005) as assessed by densitometry of immunoblots. Additionally, by immunoblotting, PBOV1 protein levels differed significantly between Grade Group 2 (GS 3 + 4) and Grade Group 3 (GS 4 + 3) PCa samples (P = 0.028). In the immunohistochemical analysis, measures of PBOV1 staining intensity strongly correlated with nuclear alterations in cancer cells. An MLR model retaining eight parameters describing PBOV1 staining intensity and nuclear architecture discriminated Grade Group 3 and above PCa from Grade Group 1 and 2 PCa and benign cancer-adjacent regions with a ROC-AUC of 0.90 and 0.80, respectively, in training and test sets. Our study demonstrates that the PBOV1 protein could be used to discriminate Grade Group 3 and above PCa. Additionally, the PBOV1 protein could be involved in modulating changes to the nuclear architecture of PCa cells. Confirmatory studies are warranted in an independent population for further validation. © 2018 Wiley Periodicals, Inc.
Goseki grade and tumour location influence survival of patients with gastric cancer.
Calik, Muhammet; Calik, Ilknur; Demirci, Elif; Altun, Eren; Gundogdu, Betul; Sipal, Sare; Gundogdu, Cemal
2014-01-01
Owing to the variability of histopathological features and biological behaviour in gastric carcinoma, a great number of categorisation methods such as classical histopathologic grading, Lauren classification, the TNM staging system and the newly presented Goseki grading method are used by pathologists and other scientists. In our study, we aimed to investigate whether Goseki grade and tumour location have an effects on survival of gastric cancer cases. Eighty-four patients with gastric adenocarcinoma were covered in the investigation. The importance of Goseki grading system and tumour location were analysed in addition to the TNM staging and other conventional prognostic parameters. The median survival time in our patients was 35 months (minimum: 5, maximum: 116). According to our findings, there was no relation between survival and tumour size (p=0.192) or classical histological type (p=0.270). In contrast, the Goseki grade and tumour location significantly correlated with survival (p=0.007 and p<0.001, respectively). Additionally, tumours of the intestinal type had a longer median survival time (60.0 months) than diffuse tumours (24.0 months). In addition to the TNM staging system, tumour location and the Goseki grading system may be used as significant prognostic parameters in patients with gastric cancer.
Automatic Grading of Spreadsheet and Database Skills
ERIC Educational Resources Information Center
Kovacic, Zlatko J.; Green, John Steven
2012-01-01
Growing enrollment in distance education has increased student-to-lecturer ratios and, therefore, increased the workload of the lecturer. This growing enrollment has resulted in mounting efforts to develop automatic grading systems in an effort to reduce this workload. While research in the design and development of automatic grading systems has a…
Building heating and cooling applications thermal energy storage program overview
NASA Technical Reports Server (NTRS)
Eissenberg, D. M.
1980-01-01
Thermal energy storage technology and development of building heating and cooling applications in the residential and commercial sectors is outlined. Three elements are identified to undergo an applications assessment, technology development, and demonstration. Emphasis is given to utility load management thermal energy system application where the stress is on the 'customer side of the meter'. Thermal storage subsystems for space conditioning and conservation means of increased thermal mass within the building envelope and by means of low-grade waste heat recovery are covered.
Yoshida, Masahito; Collin, Phillipe; Josseaume, Thierry; Lädermann, Alexandre; Goto, Hideyuki; Sugimoto, Katumasa; Otsuka, Takanobu
2018-01-01
Magnetic resonance (MR) imaging is common in structural and qualitative assessment of the rotator cuff post-operatively. Rotator cuff integrity has been thought to be associated with clinical outcome. The purpose of this study was to evaluate the inter-observer reliability of cuff integrity (Sugaya's classification) and assess the correlation between Sugaya's classification and the clinical outcome. It was hypothesized that Sugaya's classification would show good reliability and good correlation with the clinical outcome. Post-operative MR images were taken two years post-operatively, following arthroscopic rotator cuff repair. For assessment of inter-rater reliability, all radiographic evaluations for the supraspinatus muscle were done by two orthopaedic surgeons and one radiologist. Rotator cuff integrity was classified into five categories, according to Sugaya's classification. Fatty infiltration was graded into four categories, based on the Fuchs' classification grading system. Muscle hypotrophy was graded as four grades, according to the scale proposed by Warner. The clinical outcome was assessed according to the constant scoring system pre-operatively and 2 years post-operatively. Of the sixty-two consecutive patients with full-thickness rotator cuff tears, fifty-two patients were reviewed in this study. These subjects included twenty-three men and twenty-nine women, with an average age of fifty-seven years. In terms of the inter-rater reliability between orthopaedic surgeons, Sugaya's classification showed the highest agreement [ICC (2.1) = 0.82] for rotator cuff integrity. The grade of fatty infiltration and muscle atrophy demonstrated good agreement, respectively (0.722 and 0.758). With regard to the inter-rater reliability between orthopaedic surgeon and radiologist, Sugaya's classification showed good reliability [ICC (2.1) = 0.70]. On the other hand, fatty infiltration and muscle hypotrophy classifications demonstrated fair and moderate agreement [ICC (2.1) = 0.39 and 0.49]. Although no significant correlation was found between overall post-operative constant score and Sugaya's classification, Sugaya's classification indicated significant correlation with the muscle strength score. Sugaya's classification showed repeatability and good agreement between the orthopaedist and radiologist, who are involved in the patient care for the rotator cuff tear. Common classification of rotator cuff integrity with good reliability will give appropriate information for clinicians to improve the patient care of the rotator cuff tear. This classification also would be helpful to predict the strength of arm abduction in the scapular plane. IV.
Visual tree grading systems for estimating lumber yields in young and mature southern pine
Alexander Clark; Robert H. McAlister
1998-01-01
New visual tree grading systems for mature southern pine ? 35 years old and young pine ? 35 years old based on number and size of branches in the lower bole are described. A series of lumber grade yield studies was conducted to test the new grading rules. A total of 214 natural loblolly pine (Pinus taeda L.) and shortleaf pine (P. echinata Mill) trees 9 to 20 inches...
Lightweight armor system and process for producing the same
Chu, Henry S.; Bruck, H. Alan; Strempek, Gary C.; Varacalle, Jr., Dominic J.
2004-01-20
A lightweight armor system may comprise a substrate having a graded metal matrix composite layer formed thereon by thermal spray deposition. The graded metal matrix composite layer comprises an increasing volume fraction of ceramic particles imbedded in a decreasing volume fraction of a metal matrix as a function of a thickness of the graded metal matrix composite layer. A ceramic impact layer is affixed to the graded metal matrix composite layer.
Kaemmerer, Nadine; Brand, Michael; Hammon, Matthias; May, Matthias; Wuest, Wolfgang; Krauss, Bernhard; Uder, Michael; Lell, Michael M
2016-10-01
Dual-energy computed tomographic angiography (DE-CTA) has been demonstrated to improve the visualization of the head and neck vessels. The aim of this study was to test the potential of split-filter single-source dual-energy CT to automatically remove bone from the final CTA data set. Dual-energy CTA was performed in 50 consecutive patients to evaluate the supra-aortic arteries, either to grade carotid artery stenosis or to rule out traumatic dissections. Dual-energy CTA was performed on a 128-slice single-source CT system equipped with a special filter array to separate the 120-kV spectrum into a high- and a low-energy spectrum for DE-based automated bone removal. Image quality of fully automated bone suppression and subsequent manual optimization was evaluated by 2 radiologists on maximum intensity projections using a 4-grade scoring system. The effect of image reconstruction with an iterative metal artifact reduction algorithm on DE postprocessing was tested using a 3-grade scoring system, and the time demand for each postprocessing step was measured. Two patients were excluded due to insufficient arterial contrast enhancement; in the remaining 48 patients, automated bone removal could be performed successfully. The addition of iterative metal artifact reduction algorithm improved image quality in 58.3% of the cases. After manual optimization, DE-CTA image quality was rated excellent in 7, good in 29, and moderate in 10 patients. Interobserver agreement was high (κ = 0.85). Stenosis grading was not influenced using DE-CTA with bone removal as compared with the original CTA. The time demand for DE image reconstruction was significantly higher than for single-energy reconstruction (42.1 vs 20.9 seconds). Our results suggest that bone removal in DE-CTA of the head and neck vessels with a single-source CT is feasible and can be performed within acceptable time and moderate user interaction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schulte, Kevin L.; France, Ryan M.; Geisz, John F.
The development of compositionally graded buffer layers (CGBs) with enhanced transparency would enable novel five and six junction solar cells, with efficiencies approaching 50% under high concentration. Here, we demonstrate highly transparent grades between the GaAs and InP lattice constants on both A- and B-miscut GaAs substrates, employing Al xGayIn 1-x-yAs and highly Se-doped Burstein-Moss (BM) shifted Ga xIn 1-xP. Transparency to >810 and >890 nm wavelengths is demonstrated with BM-shifted Ga xIn 1-xP on B-miscut substrates and Al xGayIn 1-x-yAs/Ga xIn 1-xP(Se) combined grades on A-miscut substrates, respectively. 0.74 eV GaInAs solar cells grown on these transparent CGBs exhibitmore » Woc = 0.41 V at mA/ cm 2, performance comparable with the state-of-the-art Ga xIn 1-xP grade employed in the four-junction-inverted metamorphic multijunction (IMM) cell. A GaAs/0.74cV GaInAs tandem cell was grown with a transparent BM-shifted Ga xIn 1-xP CGB to verify the CGB performance in a multijunction device structure. Quantum efficiency measurements indicate that the CGB is completely transparent to photons below the GaAs bandedge, validating its use in 4-6 junction IMM devices with a single-graded buffer. Furthermore, this tandem represents a highly efficient two-junction band gap combination, achieving 29.6% ± 1.2% efficiency under the AM1.5 global spectrum, demonstrating how the additional transparency enables new device structures.« less
Schulte, Kevin L.; France, Ryan M.; Geisz, John F.
2016-11-11
The development of compositionally graded buffer layers (CGBs) with enhanced transparency would enable novel five and six junction solar cells, with efficiencies approaching 50% under high concentration. Here, we demonstrate highly transparent grades between the GaAs and InP lattice constants on both A- and B-miscut GaAs substrates, employing Al xGayIn 1-x-yAs and highly Se-doped Burstein-Moss (BM) shifted Ga xIn 1-xP. Transparency to >810 and >890 nm wavelengths is demonstrated with BM-shifted Ga xIn 1-xP on B-miscut substrates and Al xGayIn 1-x-yAs/Ga xIn 1-xP(Se) combined grades on A-miscut substrates, respectively. 0.74 eV GaInAs solar cells grown on these transparent CGBs exhibitmore » Woc = 0.41 V at mA/ cm 2, performance comparable with the state-of-the-art Ga xIn 1-xP grade employed in the four-junction-inverted metamorphic multijunction (IMM) cell. A GaAs/0.74cV GaInAs tandem cell was grown with a transparent BM-shifted Ga xIn 1-xP CGB to verify the CGB performance in a multijunction device structure. Quantum efficiency measurements indicate that the CGB is completely transparent to photons below the GaAs bandedge, validating its use in 4-6 junction IMM devices with a single-graded buffer. Furthermore, this tandem represents a highly efficient two-junction band gap combination, achieving 29.6% ± 1.2% efficiency under the AM1.5 global spectrum, demonstrating how the additional transparency enables new device structures.« less
Soukup, Viktor; Čapoun, Otakar; Cohen, Daniel; Hernández, Virginia; Babjuk, Marek; Burger, Max; Compérat, Eva; Gontero, Paolo; Lam, Thomas; MacLennan, Steven; Mostafid, A Hugh; Palou, Joan; van Rhijn, Bas W G; Rouprêt, Morgan; Shariat, Shahrokh F; Sylvester, Richard; Yuan, Yuhong; Zigeuner, Richard
2017-11-01
Tumour grade is an important prognostic indicator in non-muscle-invasive bladder cancer (NMIBC). Histopathological classifications are limited by interobserver variability (reproducibility), which may have prognostic implications. European Association of Urology NMIBC guidelines suggest concurrent use of both 1973 and 2004/2016 World Health Organization (WHO) classifications. To compare the prognostic performance and reproducibility of the 1973 and 2004/2016 WHO grading systems for NMIBC. A systematic literature search was undertaken incorporating Medline, Embase, and the Cochrane Library. Studies were critically appraised for risk of bias (QUIPS). For prognosis, the primary outcome was progression to muscle-invasive or metastatic disease. Secondary outcomes were disease recurrence, and overall and cancer-specific survival. For reproducibility, the primary outcome was interobserver variability between pathologists. Secondary outcome was intraobserver variability (repeatability) by the same pathologist. Of 3593 articles identified, 20 were included in the prognostic review; three were eligible for the reproducibility review. Increasing tumour grade in both classifications was associated with higher disease progression and recurrence rates. Progression rates in grade 1 patients were similar to those in low-grade patients; progression rates in grade 3 patients were higher than those in high-grade patients. Survival data were limited. Reproducibility of the 2004/2016 system was marginally better than that of the 1973 system. Two studies on repeatability showed conflicting results. Most studies had a moderate to high risk of bias. Current grading classifications in NMIBC are suboptimal. The 1973 system identifies more aggressive tumours. Intra- and interobserver variability was slightly less in the 2004/2016 classification. We could not confirm that the 2004/2016 classification outperforms the 1973 classification in prediction of recurrence and progression. This article summarises the utility of two different grading systems for non-muscle-invasive bladder cancer. Both systems predict progression and recurrence, although pathologists vary in their reporting; suggestions for further improvements are made. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Kobayashi, Sarah; Peduto, Anthony; Simic, Milena; Fransen, Marlene; Refshauge, Kathryn; Mah, Jean; Pappas, Evangelos
2018-04-01
This work aimed to assess inter-rater reliability and agreement of a magnetic resonance imaging (MRI)-based Kellgren and Lawrence (K&L) grading for patellofemoral joint osteoarthritis (OA) and to validate it against the MRI Osteoarthritis Knee Score (MOAKS). MRI scans from people aged 45 to 75 years with chronic knee pain participating in a randomised clinical trial evaluating dietary supplements were utilised. Fifty participants were randomly selected and scored using the MRI-based K&L grading using axial and sagittal MRI scans. Raters conducted inter-rater reliability, blinded to clinical information, radiology reports and other rater results. Intra- and inter-rater reliability and agreement were evaluated using the intra-class correlation coefficient (ICC) and Cohen's weighted kappa. There was a 2-week interval between the first and second readings for intra-rater reliability. Validity was assessed using the MOAKS and evaluated using Spearman's correlation coefficient. Intra-rater reliability of the K&L system was excellent: ICC 0.91 (95% CI 0.82-0.95); weighted kappa (ĸ = 0.69). Inter-rater reliability was high (ICC 0.88; 95% CI 0.79-0.93), while agreement between raters was moderate (ĸ = 0.49-0.57). Validity analysis demonstrated a strong correlation between the total MOAKS features score and the K&L grading system (ρ = 0.62-0.67) but weak correlations when compared with individual MOAKS features (ρ = 0.19-0.61). The high reliability and good agreement show consistency in grading the severity of patellofemoral OA with the MRI-based K&L score. Our validity results suggest that the scale may be useful, particularly in the clinical environment. Future research should validate this method against clinical findings.
Is the Sky Falling? Grade Inflation and the Signaling Power of Grades
ERIC Educational Resources Information Center
Pattison, Evangeleen; Grodsky, Eric; Muller, Chandra
2013-01-01
Grades are the fundamental currency of our educational system; they signal academic achievement and noncognitive skills to parents, employers, postsecondary gatekeepers, and students themselves. Grade inflation compromises the signaling value of grades and undermines their capacity to achieve the functions for which they are intended. We challenge…
5 CFR 842.206 - Involuntary retirement.
Code of Federal Regulations, 2010 CFR
2010-01-01
...; and (iv) Not lower than the equivalent of two grades or pay levels below the employee's current grade or pay level, without consideration of the employee's eligibility to retain his or her current grade... systems, the comparison rate of the grade or pay level that is two grades below that of the current...
The Grades Transfer from One Grading Scale to Other Algorithmization
ERIC Educational Resources Information Center
Lieponiene, Jurgita; Kulvietiene, Regina
2011-01-01
The article presents the consideration of grading scales used for education outcomes in different countries, describes likeness and differences of applied grading scales. Application of the European Credit Transfer and Accumulation System (ECTS) grading scale is investigated according of the analysis of scientific literature as well as cases of…
Sticca, Fabio; Goetz, Thomas; Bieg, Madeleine; Hall, Nathan C; Eberle, Franz; Haag, Ludwig
2017-01-01
The present longitudinal study examined the reliability of self-reported academic grades across three phases in four subject domains for a sample of 916 high-school students. Self-reported grades were found to be highly positively correlated with actual grades in all academic subjects and across grades 9 to 11 underscoring the reliability of self-reported grades as an achievement indicator. Reliability of self-reported grades was found to differ across subject areas (e.g., mathematics self-reports more reliable than language studies), with a slight yet consistent tendency to over-report achievement levels also observed across grade levels and academic subjects. Overall, the absolute value of over- and underreporting was low and these patterns were not found to differ between mathematics and verbal subjects. In sum, study findings demonstrate the consistent predictive utility of students' self-reported achievement across grade levels and subject areas with the observed tendency to over-report academic grades and slight differences between domains nonetheless warranting consideration in future education research.
Goetz, Thomas
2017-01-01
The present longitudinal study examined the reliability of self-reported academic grades across three phases in four subject domains for a sample of 916 high-school students. Self-reported grades were found to be highly positively correlated with actual grades in all academic subjects and across grades 9 to 11 underscoring the reliability of self-reported grades as an achievement indicator. Reliability of self-reported grades was found to differ across subject areas (e.g., mathematics self-reports more reliable than language studies), with a slight yet consistent tendency to over-report achievement levels also observed across grade levels and academic subjects. Overall, the absolute value of over- and underreporting was low and these patterns were not found to differ between mathematics and verbal subjects. In sum, study findings demonstrate the consistent predictive utility of students’ self-reported achievement across grade levels and subject areas with the observed tendency to over-report academic grades and slight differences between domains nonetheless warranting consideration in future education research. PMID:29112979
Terahertz reflectometry imaging for low and high grade gliomas
NASA Astrophysics Data System (ADS)
Ji, Young Bin; Oh, Seung Jae; Kang, Seok-Gu; Heo, Jung; Kim, Sang-Hoon; Choi, Yuna; Song, Seungri; Son, Hye Young; Kim, Se Hoon; Lee, Ji Hyun; Haam, Seung Joo; Huh, Yong Min; Chang, Jong Hee; Joo, Chulmin; Suh, Jin-Suck
2016-10-01
Gross total resection (GTR) of glioma is critical for improving the survival rate of glioma patients. One of the greatest challenges for achieving GTR is the difficulty in discriminating low grade tumor or peritumor regions that have an intact blood brain barrier (BBB) from normal brain tissues and delineating glioma margins during surgery. Here we present a highly sensitive, label-free terahertz reflectometry imaging (TRI) that overcomes current key limitations for intraoperative detection of World Health Organization (WHO) grade II (low grade), and grade III and IV (high grade) gliomas. We demonstrate that TRI provides tumor discrimination and delineation of tumor margins in brain tissues with high sensitivity on the basis of Hematoxylin and eosin (H&E) stained image. TRI may help neurosurgeons to remove gliomas completely by providing visualization of tumor margins in WHO grade II, III, and IV gliomas without contrast agents, and hence, improve patient outcomes.
Goatman, Keith; Charnley, Amanda; Webster, Laura; Nussey, Stephen
2011-01-01
To assess the performance of automated disease detection in diabetic retinopathy screening using two field mydriatic photography. Images from 8,271 sequential patient screening episodes from a South London diabetic retinopathy screening service were processed by the Medalytix iGrading™ automated grading system. For each screening episode macular-centred and disc-centred images of both eyes were acquired and independently graded according to the English national grading scheme. Where discrepancies were found between the automated result and original manual grade, internal and external arbitration was used to determine the final study grades. Two versions of the software were used: one that detected microaneurysms alone, and one that detected blot haemorrhages and exudates in addition to microaneurysms. Results for each version were calculated once using both fields and once using the macula-centred field alone. Of the 8,271 episodes, 346 (4.2%) were considered unassessable. Referable disease was detected in 587 episodes (7.1%). The sensitivity of the automated system for detecting unassessable images ranged from 97.4% to 99.1% depending on configuration. The sensitivity of the automated system for referable episodes ranged from 98.3% to 99.3%. All the episodes that included proliferative or pre-proliferative retinopathy were detected by the automated system regardless of configuration (192/192, 95% confidence interval 98.0% to 100%). If implemented as the first step in grading, the automated system would have reduced the manual grading effort by between 2,183 and 3,147 patient episodes (26.4% to 38.1%). Automated grading can safely reduce the workload of manual grading using two field, mydriatic photography in a routine screening service.
Tamai, Tsutomu; Taniyama, Oki; Oda, Kohei; Kasai, Ai; Ijyuin, Syo; Sakae, Haruka; Onishi, Hiroka; Tabu, Kazuaki; Kumagai, Kotaro; Mawatari, Seiichi; Moriuchi, Akihiro; Uto, Hirofumi; Ido, Akio
2018-05-01
We confirmed the clinical utility of a three-dimensional navigation system during transarterial chemoembolization. We evaluated 128 tumors in 91 patients enrolled between May 2015 and August 2016. We evaluated the accuracy of the three-dimensional navigation imaging system for all tumors. We compared the patients who were able to undergo route detection using three-dimensional navigation with previously treated patients who underwent transarterial chemoembolization without using three-dimensional navigation (n = 21). For 38 patients who underwent super-selective microcatheter insertion after a feeding artery was identified by three-dimensional navigation, we confirmed the relationship between the tumors and contrasted liver parenchyma and divided the computed tomography hepatic arteriography findings into four grades. Grade 1: an overlap of > 5 mm, grade 2: an overlap between 0 and 5 mm, grade 3: the borders of the tumor within the liver parenchyma but in contact with the edges, and grade 4: a tumor outside the borders of the liver parenchyma. Using the three-dimensional navigation system, we identified a tumor-feeding artery in 125/128 tumors (97.6%). Furthermore, this system allowed us to significantly reduce the volume of contrast media and the radiation exposure dose in patients undergoing an evaluation. We identified 15 grade 1 tumors (39.5%), 3 grade 2 tumors (7.9%), 11 grade 3 tumors (28.9%), and 9 grade 4 tumors (23.7%) according to our definitions. The three-dimensional navigation is useful not only for patients but also for surgeons who have relatively little experience. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Kim, Brian J; Merchant, Madhur; Zheng, Chengyi; Thomas, Anil A; Contreras, Richard; Jacobsen, Steven J; Chien, Gary W
2014-12-01
Natural language processing (NLP) software programs have been widely developed to transform complex free text into simplified organized data. Potential applications in the field of medicine include automated report summaries, physician alerts, patient repositories, electronic medical record (EMR) billing, and quality metric reports. Despite these prospects and the recent widespread adoption of EMR, NLP has been relatively underutilized. The objective of this study was to evaluate the performance of an internally developed NLP program in extracting select pathologic findings from radical prostatectomy specimen reports in the EMR. An NLP program was generated by a software engineer to extract key variables from prostatectomy reports in the EMR within our healthcare system, which included the TNM stage, Gleason grade, presence of a tertiary Gleason pattern, histologic subtype, size of dominant tumor nodule, seminal vesicle invasion (SVI), perineural invasion (PNI), angiolymphatic invasion (ALI), extracapsular extension (ECE), and surgical margin status (SMS). The program was validated by comparing NLP results to a gold standard compiled by two blinded manual reviewers for 100 random pathology reports. NLP demonstrated 100% accuracy for identifying the Gleason grade, presence of a tertiary Gleason pattern, SVI, ALI, and ECE. It also demonstrated near-perfect accuracy for extracting histologic subtype (99.0%), PNI (98.9%), TNM stage (98.0%), SMS (97.0%), and dominant tumor size (95.7%). The overall accuracy of NLP was 98.7%. NLP generated a result in <1 second, whereas the manual reviewers averaged 3.2 minutes per report. This novel program demonstrated high accuracy and efficiency identifying key pathologic details from the prostatectomy report within an EMR system. NLP has the potential to assist urologists by summarizing and highlighting relevant information from verbose pathology reports. It may also facilitate future urologic research through the rapid and automated creation of large databases.
Office Skills: Demonstration Skills Affect Students' Typing Techniques.
ERIC Educational Resources Information Center
Clinkscale, Bella G.
1979-01-01
Demonstration of typewriting techniques by the teacher should be part of the instruction in every typewriting course, according to the author, who presents specific steps in conducting the demonstration, checking student performance, and grading rationale. (MF)
33 CFR 157.130 - Crude oil washing with more than one grade of crude oil.
Code of Federal Regulations, 2010 CFR
2010-07-01
... RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Design... vessel having a COW system under §§ 157.10(e), 157.10a(a)(2), or 157.10c(b)(2) carries more than one grade of crude oil, the COW system must be capable of washing the cargo tanks with the grades of crude...
Xiao-Jun, Meng; Sheng-Hua, Zong; Xuan, Zhang; Dong-Lin, Gao; Yan-Hua, Qian; Bing, Lu
2017-07-27
To establish a risk assessing indicator system after the transmission interruption of schistosomiasis in Wuxi City, so as to provide evidences for formulating strategies on schistosomiasis control and prevention. A primary risk assessing indicator system was established based on the literature review. Alternative indicators were scored and screened to establish a final indicator system through two rounds of Delphy method and the related normalized weights and combined weights were also calculated. The risk assessing indicator system was established through two rounds of expert consultation including 3 first grade indicators and 15 second grade indicators. Among the first grade indicators, the normalized weights of natural environment, key populations and social environment were 0.370 6, 0.292 9 and 0.336 5, respectively. Among the second grade indicators, the migrant population accounted for the highest combined weight of 0.125 2 compared to domestic animal of 0.037 1. The authority degree among the first grade indicators was between 0.91 and 0.93, while the authority degree among the second grade indicators was between 0.79 and 0.92. The scientific and authoritative risk assessing indicator system after the transmission interruption of schistosomiasis is established, which provides the evidences for risk assessment on schistosomiasis transmission in Wuxi City.
Optical probe for porosity defect detection on inner diameter surfaces of machined bores
NASA Astrophysics Data System (ADS)
Kulkarni, Ojas P.; Islam, Mohammed N.; Terry, Fred L.
2010-12-01
We demonstrate an optical probe for detection of porosity inside spool bores of a transmission valve body with diameters down to 5 mm. The probe consists of a graded-index relay rod that focuses a laser beam spot onto the inner surface of the bore. Detectors, placed in the specular and grazing directions with respect to the incident beam, measure the change in scattered intensity when a surface defect is encountered. Based on the scattering signatures in the two directions, the system can also validate the depth of the defect and distinguish porosity from bump-type defects coming out of the metal surface. The system can detect porosity down to a 50-μm lateral dimension and ~40 μm in depth with >3-dB contrast over the background intensity fluctuations. Porosity detection systems currently use manual inspection techniques on the plant floor, and the demonstrated probe provides a noncontact technique that can help automotive manufacturers meet high-quality standards during production.
A comparison of healing rates on two pressure-relieving systems.
Russell, L; Reynolds, T; Carr, J; Evans, A; Holmes, M
The authors have previously reported the preliminary results of a randomized-controlled trial comparing the relative efficacy of two pressure-relieving systems: Huntleigh Nimbus 3 and Aura Cushion, and Pegasus Cairwave Therapy System and ProActive Seating Cushion (Russell et al, 2000). Although both the mattresses and cushions were effective treatments for pressure ulcers, the Huntleigh equipment was demonstrated to be statistically more effective for heel ulcers, but no differences were demonstrated for sacral ulcers. This article gives a more detailed analysis of the 141 patients assessed using computerized-image analysis of the digital images of sacral ulcers captured during the trial and specifically discusses the healing rates and other patient characteristics. Ninety-eight per cent of ulcers examined were deemed superficial (Torrance grade 2a, 2b, 3). Precision of image analysis assessed by within- and between-batch coefficients of variation was excellent: calibration CV 0.93-1.84%; area CV 4.61-5.72%. The healing rates on the two mattresses were not shown to be statistically different from each other.
Use of commercial grade item dedication to reduce procurement costs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosch, F.
1995-09-01
In the mid-1980s, the Nuclear Regulatory Industry (NRC) began inspecting utility practices of procuring and dedicating commercial grade items intended for plant safety-related applications. As a result of the industry efforts to address NRC concerns, nuclear utilities have enhanced existing programs and procedures for dedication of commercial grade items. Though these programs were originally enhanced to meet NRC concerns, utilities have discovered that the dedication of commercial grade items can also reduce overall procurement costs. This paper will discuss the enhancement of utility dedication programs and demonstrates how utilities have utilized them to reduce procurement costs.
A Systematic Review of Longitudinal Studies of Mathematics Difficulty.
Nelson, Gena; Powell, Sarah R
2017-06-01
Some students may be diagnosed with a learning disability in mathematics or dyscalculia, whereas other students may demonstrate below-grade-level mathematics performance without a disability diagnosis. In the literature, researchers often identify students in both groups as experiencing math difficulty. To understand the performance of students with math difficulty, we examined 35 studies that reported longitudinal results of mathematics achievement (i.e., mathematics performance measured across at least a 12-month span). Our primary goal was to conduct a systematic review of these studies and to understand whether the growth of students with math difficulty was comparable or stagnant when compared with that of students without math difficulty. We also analyzed whether identification of math difficulty was predictive of mathematics achievement in later grades and whether a diagnosis of math difficulty was stable across grade levels. Results indicate that students with math difficulty demonstrate growth on mathematics measures, but this growth still leads to lower performance than that of students without math difficulty. Identification of math difficulty is strongly related to math performance in subsequent grades, and this diagnosis is often stable. Collectively, this literature indicates that students with math difficulty continue to struggle with mathematics in later grades.
Selection and evaluation of performance-graded asphalt binders for Virginia.
DOT National Transportation Integrated Search
1999-06-01
This study recommended performance-graded (PG) binders to be used in hot-mix asphalt in Virginia. Ten conventional viscosity-graded asphalt cements, representing the asphalt typically available in Virginia, were graded under the PG system to develop ...
A versatile digitally-graded buffer structure for metamorphic device applications
NASA Astrophysics Data System (ADS)
Ma, Yingjie; Zhang, Yonggang; Chen, Xingyou; Gu, Yi; Shi, Yanhui; Ji, Wanyan; Du, Ben
2018-04-01
Exploring more effective buffer schemes for mitigating dislocation deficiencies is the key technology towards higher performance metamorphic devices. Here we demonstrate a versatile metamorphic grading structure consisting of 38-period alternated multilayers of In0.52Al0.48As and In0.82Al0.18As on InP substrate, thicknesses of which in each period were gradually varied in opposite directions from 48.7 and 1.3 nm to 1.3 and 48.7 nm, respectively, akin to a digital alloy. Both preferentially dislocation nucleation and blocking of threading dislocation transmission are observed near the In0.82Al0.18As/In0.52Al0.48As interfaces, which help relax the strain and lower the residual defect density. A 2.6 μm In0.83Ga0.17As pin photodetector is fabricated on this pseudo-substrate, attaining a low dark current density of 2.9 × 10‑6 A cm‑2 and a high detectivity of 1.8 × 1010 cmHz1/2W‑1 at room temperature, comparable with the states of the art that on linearly-graded buffer layers. These results indicate such digitally-graded buffer structures are promising for enhancing performances of metamorphic devices, and can be easily generalized to other lattice-mismatched material systems.
Montes-Fonseca, Silvia Lorena; Sánchez-Ramírez, Blanca; Luna-Velasco, Antonia; Arzate-Quintana, Carlos; Silva-Cazares, Macrina Beatriz; González Horta, Carmen
2015-01-01
Carbon nanotubes (CNTs) are used as carriers in medicine due to their ability to be functionalized with chemical substances. However, cytotoxicity analysis is required prior to use for in vivo models. The aim of this study was to evaluate the cytotoxic effect of CNTs functionalized with a 46 kDa surface protein from Entamoeba histolytica (P46-CNTs) on J774A macrophages. With this purpose, CNTs were synthesized by spray pyrolysis and purified (P-CNTs) using sonication for 48 h. A 46 kDa protein, with a 4.6–5.4 pI range, was isolated from E. histolytica HM1:IMSS strain trophozoites using an OFFGEL system. The P-CNTs were functionalized with the purified 46 kDa protein, classified according to their degree of functionalization, and characterized by Raman and Infrared spectroscopy. In vitro cytotoxicity was evaluated by MTT, apoptosis, and morphological assays. The results demonstrated that P46-CNTs exhibited cytotoxicity dependent upon the functionalized grade. Contrary to what was expected, P46-CNTs with a high grade of functionalization were more toxic to J774 macrophages than P46-CNTs with a low grade of functionalization, than P-CNTs, and had a similar level of toxicity as UP-CNT. This suggests that the nature of the functionalized protein plays a key role in the cytotoxicity of these nanoparticles. PMID:26075262
Ramirez-Dorronsoro, Juan-Carlos; Jacko, Robert B; Kildsig, Dane O
2006-01-01
The purpose of this study was to develop an instrument (the Purdue instrument) and the corresponding methodologies to measure the electrostatic charge development (chargeability) of dry powders when they are in dynamic contact with stainless steel surfaces. The system used an inductive noncontact sensor located inside an aluminum Faraday cage and was optimized to measure the charging capabilities of a fixed volume of powder (0.5 cc). The chargeability of 5,5-diphenyl-hydantoin, calcium sulfate dihydrate, cimetidine, 3 grades of colloidal silicon dioxide, magnesium stearate, 4 grades of microcrystalline cellulose, salicylic acid, sodium carbonate, sodium salicylate, spray-dried lactose, and sulfinpyrazone were tested at 4 linear velocities, and the particle size distribution effect was assessed for 3 different grades of colloidal silicon dioxide and 4 different grades of microcrystalline cellulose. The chargeability values exhibited a linear relationship for the range of velocities studied, with colloidal silicon dioxide exhibiting the maximum negative chargeability and with spray-dried lactose being the only compound to exhibit positive chargeability. The instrument sensitivity was improved by a factor of 2 over the first generation version, and the electrostatic charge measurements were reproducible with relative standard deviations ranging from nondetectable to 33.7% (minimum of 3 replicates). These results demonstrate the feasibility of using the Purdue instrument to measure the electrostatic charge control capabilities of pharmaceutical dry powders with a reasonable level of precision.
DOT National Transportation Integrated Search
1977-02-28
This report, Volume II of a two-volume study, examines the potential for reduction of the cost of installing and maintaining automatic gates at railroad-highway grade crossings. It includes a review of current practices, equipment, and standards; con...
DOT National Transportation Integrated Search
1977-02-28
This report, Volume I of a two-volume study, examines the potential for reduction of the cost of installing and maintaining automatic gates at railroad-highway grade crossings. It comprises a general overview; a review of current practices, equipment...
Gearing up for Fast Grading and Reporting
ERIC Educational Resources Information Center
O'Connor, Ken; Jung, Lee Ann; Reeves, Douglas
2018-01-01
The authors posit that the traditional grading system involving points and percentages is not the best way to prepare students to be the self-directed, independent learners they need to be. A better system would produce grades that are FAST (fair, accurate, specific, timely). To bring about these changes, school leaders need not create full…
7 CFR 52.1003 - Grades of dates.
Code of Federal Regulations, 2010 CFR
2010-01-01
... PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1... the scoring system outlined in this subpart. (b) U.S. Grade B or U.S. Choice is the quality of whole... the scoring system outlined in this subpart. (c) U.S. Grade B (Dry) or U.S. Choice (Dry) is the...
Vemulakonda, V M; Wilcox, D T; Torok, M R; Hou, A; Campbell, J B; Kempe, A
2015-09-01
The most common measurements of hydronephrosis are the anterior-posterior (AP) diameter and the Society for Fetal Urology (SFU) grading systems. To date, the inter-rater reliability (IRR) of these measures has not been compared in the postnatal period. The objectives of this study were to compare the IRR of the AP diameter and the SFU grading system in infants and to determine whether ultrasound findings other than pelvicalyceal dilation are associated with higher SFU grades. Initial postnatal ultrasounds of infants seen from February 1, 2011, to January 31, 2012, with a primary diagnosis of congenital hydronephrosis were included for review. Ultrasound images were de-identified and reviewed by four pediatric urologists. IRR was calculated using the intraclass correlation (ICC) measure. A paired t test was used to compare ICCs. Associations between SFU grade and other ultrasound findings were tested using Chi-square or Fisher's exact tests. A total of 112 kidneys in 56 patients were reviewed. IRR of the SFU grading system was high (right kidney ICC = 0.83, left kidney ICC = 0.85); however, IRR of AP diameter measurement was higher (right kidney ICC = 00.97, left kidney ICC = 0.98; p < 0.001). Renal asymmetry (p < 0.001), echogenicity (p < 0.001), and parenchymal thinning (p < 0.001) were significantly associated with SFU grade 4 hydronephrosis on bivariable and multivariable analysis. The SFU grading system is associated with excellent IRR, although the AP diameter appears to have higher IRR. Physicians may consider ultrasound findings that are not explicitly included in the SFU system when assigning hydronephrosis grade, which may lead to variability in use of this classification system.
Jin, Mengran; Liu, Zhen; Liu, Xingyong; Yan, Huang; Han, Xiao; Qiu, Yong; Zhu, Zezhang
2016-06-01
To assess the accuracy of O-arm-navigation-based pedicle screw insertion in dystrophic scoliosis secondary to NF-1 and compare it with free-hand pedicle screw insertion technique. 32 patients with dystrophic NF-1-associated scoliosis were divided into two groups. A total of 92 pedicle screws were implanted in apical region (two vertebrae above and below the apex each) in 13 patients using O-arm-based navigation (O-arm group), and 121 screws were implanted in 19 patients using free-hand technique (free-hand group). The postoperative CT images were reviewed and analyzed for pedicle violation. The screw penetration was divided into four grades: grade 0 (ideal placement), grade 1 (penetration <2 mm), grade 2 (penetration between 2 and 4 mm), and grade 3 (penetration >4 mm). The accuracy rate of pedicle screw placement (grade 0, 1) was significantly higher in the O-arm group (79 %, 73/92) compared to 67 % (81/121) of the free-hand group (P = 0.045). Meanwhile, a significantly lower prevalence of grade 2-3 perforation was observed in the O-arm group (21 vs. 33 %, P < 0.05), and the incidence of medial perforation was significantly minimized by using O-arm navigation compared to free-hand technique (2 vs. 15 %, P < 0.01). Moreover, the implant density in apical region was significantly elevated by using O-arm navigation (58 vs. 42 %, P < 0.001). We reported 79 % accuracy of O-arm-based pedicle screw placement in dystrophic NF-1-associated scoliosis. O-arm navigation system does facilitate pedicle screw insertion in dystrophic NF-1-associated scoliosis, demonstrating superiorities in the safety and accuracy of pedicle screw placement in comparison with free-hand technique.
Bohannon, Richard W; Harrison, Steven; Kinsella-Shaw, Jeffrey
2009-01-01
Background Spasticity is a common impairment accompanying stroke. Spasticity of the quadriceps femoris muscle can be quantified using the pendulum test. The measurement properties of pendular kinematics captured using a magnetic tracking system has not been studied among patients who have experienced a stroke. Therefore, this study describes the test-retest reliability and known groups and convergent validity of the pendulum test measures obtained with the Polhemus tracking system. Methods Eight patients with chronic stroke underwent pendulum tests with their affected and unaffected lower limbs, with and without the addition of a 2.2 kg cuff weight at the ankle, using the Polhemus magnetic tracking system. Also measured bilaterally were knee resting angles, Ashworth scores (grades 0–4) of quadriceps femoris muscles, patellar tendon (knee jerk) reflexes (grades 0–4), and isometric knee extension force. Results Three measures obtained from pendular traces of the affected side were reliable (intraclass correlation coefficient ≥ .844). Known groups validity was confirmed by demonstration of a significant difference in the measurements between sides. Convergent validity was supported by correlations ≥ .57 between pendulum test measures and other measures reflective of spasticity. Conclusion Pendulum test measures obtained with the Polhemus tracking system from the affected side of patients with stroke have good test-retest reliability and both known groups and convergent validity. PMID:19642989
Bohannon, Richard W; Harrison, Steven; Kinsella-Shaw, Jeffrey
2009-07-30
Spasticity is a common impairment accompanying stroke. Spasticity of the quadriceps femoris muscle can be quantified using the pendulum test. The measurement properties of pendular kinematics captured using a magnetic tracking system has not been studied among patients who have experienced a stroke. Therefore, this study describes the test-retest reliability and known groups and convergent validity of the pendulum test measures obtained with the Polhemus tracking system. Eight patients with chronic stroke underwent pendulum tests with their affected and unaffected lower limbs, with and without the addition of a 2.2 kg cuff weight at the ankle, using the Polhemus magnetic tracking system. Also measured bilaterally were knee resting angles, Ashworth scores (grades 0-4) of quadriceps femoris muscles, patellar tendon (knee jerk) reflexes (grades 0-4), and isometric knee extension force. Three measures obtained from pendular traces of the affected side were reliable (intraclass correlation coefficient > or = .844). Known groups validity was confirmed by demonstration of a significant difference in the measurements between sides. Convergent validity was supported by correlations > or = .57 between pendulum test measures and other measures reflective of spasticity. Pendulum test measures obtained with the Polhemus tracking system from the affected side of patients with stroke have good test-retest reliability and both known groups and convergent validity.
Handwashing among schoolchildren in an ethnically diverse population in northern rural Vietnam
Xuan, Le Thi Thanh; Hoat, Luu Ngoc
2013-01-01
Background Handwashing with soap (HWWS) is a simple and effective measure to prevent transmission of fecal–oral disease and other infectious diseases in school-age children. To promote the behavior, we need to understand their HWWS compliance. The aim of this article is to describe handwashing behavior and HWWS compliance and to identify associated factors among schoolchildren in the multiethnic rural area of northern Vietnam. Methods The study was conducted in six primary and secondary schools and in the homes of four ethnic villages in northern Vietnam. Quantitative methods included face-to-face interviews with, and demonstration of handwashing protocol to, 319 schoolchildren in first, fourth, and seventh grades. Qualitative methods included structured observations at six schools and 20 homes comprising 24 children. The dependent variable was the self-reported HWWS behavior (yes/no). The independent variables included grade, school type, gender, ethnicity group, owning home latrine, and household assets. Logistic regression modelling was performed to examine associations between HWWS behavior and demographic factors. Results Among the 319 schoolchildren interviewed, 66% reported HWWS. Through the demonstration protocol, only 10 out of 319 schoolchildren, performed HWWS satisfactorily. The percentage of students who washed their hands at recommended times (30–60 sec) was 58%. This proportion increased by grade (from 34% among grade 1 to 67% among grade 7; p<0.05). Correlates of self-reported HWWS were more common in higher grades [grade 4 vs. grade 1: odds ratio (OR)=4.14 (2.00–8.56), grade 7 vs. grade 1: OR=7.76 (3.67–16.4)] and less common in ethnic minority groups [Xa Phó vs. Kinh-Tay: OR=0.28 (0.11–0.70)]. All 20 homes of schoolchildren visited had soap and water but none of the six schools had soap for handwashing. Conclusions This article describes poor compliance of schoolchildren with HWWS in a multiethnic population in Vietnam. Education on handwashing needs to be prioritized among multiethnic children at school. PMID:23374701
TREEGRAD: a grading program for eastern hardwoods
J.W. Stringer; D.W. Cremeans
1991-01-01
Assigning tree grades to eastern hardwoods is often a difficult task for neophyte graders. Recently several "dichotomous keys" have been developed for training graders in the USFS hardwood tree grading system. TREEGRAD uses the Tree Grading Algorithm (TGA) for determining grades from defect location data and is designed to be used as a teaching aid.
What's in a Grade? Grading Policies and Practices in Principles of Economics
ERIC Educational Resources Information Center
Walstad, William B.; Miller, Laurie A.
2016-01-01
Survey results from a national sample of economics instructors describe the grading policies and practices in principles of economics courses. The survey results provide insights about absolute and relative grading systems used by instructors, the course components and their weights that determine grades, and the type of assessment items used for…
Ding, Xiao-Jie; Qin, Zhi-Yong; Hong, Christopher S.; Chen, Ling-Chao; Zhang, Xin; Zhao, Fang-Ping; Wang, Yin; Wang, Yang; Zhou, Liang-Fu; Zhuang, Zhengping; Ng, Ho-Keung; Yan, Hai; Yao, Yu; Mao, Ying
2015-01-01
IDH mutations frequently occur in WHO grade II and III diffuse gliomas and have favorable prognosis compared to wild-type tumors. However, whether IDH mutations in WHO grade II and II diffuse gliomas predict enhanced sensitivity to adjuvant radiation (RT) or chemotherapy (CHT) is still being debated. Recent studies have identified recurrent mutations in the promoter region of telomerase reverse transcriptase (TERT) in gliomas. We previously demonstrated that TERT promoter mutations may be promising biomarkers in glioma survival prognostication when combined with IDH mutations. This study analyzed IDH and TERT promoter mutations in 295 WHO grade II and III diffuse gliomas treated with or without adjuvant therapies to explore their impact on the sensitivity of tumors to genotoxic therapies. IDH mutations were found in 216 (73.2%) patients and TERT promoter mutations were found in 112 (38%) patients. In multivariate analysis, IDH mutations (p < 0.001) were independent prognostic factors for PFS and OS in patients receiving genotoxic therapies while TERT promoter mutations were not. In univariate analysis, IDH and TERT promoter mutations were not significant prognostic factors in patients who did not receive genotoxic therapies. Adjuvant RT and CHT were factors independently impacting PFS (RT p = 0.001, CHT p = 0.026) in IDH mutated WHO grade II and III diffuse gliomas but not in IDH wild-type group. Univariate and multivariate analyses demonstrated TERT promoter mutations further stratified IDH wild-type WHO grade II and III diffuse gliomas into two subgroups with different responses to genotoxic therapies. Adjuvant RT and CHT were significant parameters influencing PFS in the IDH wt/TERT mut subgroup (RT p = 0.015, CHT p = 0.015) but not in the IDH wt/TERT wt subgroup. Our data demonstrated that IDH mutated WHO grade II and III diffuse gliomas had better PFS and OS than their IDH wild-type counterparts when genotoxic therapies were administered after surgery. Importantly, we also found that TERT promoter mutations further stratify IDH wild-type WHO grade II and III diffuse gliomas into two subgroups with different responses to adjuvant therapies. Taken together, TERT promoter mutations may predict enhanced sensitivity to genotoxic therapies in IDH wild-type WHO grade II and III diffuse gliomas and may justify intensified treatment in this subgroup. PMID:26314843
Technological Innovation in Grade Crossing Protective Systems
DOT National Transportation Integrated Search
1971-06-01
The constraints on innovative grade crossing protective systems are delineated and guidelines for development indicated. Inventory data has been arranged to permit an estimate of the classes of systems needed, the allowable costs, and contribution of...
Winters, Brian; Wessells, Hunter; Voelzke, Bryan B
2016-03-01
One criticism of the existing renal trauma research is the limited outpatient follow-up after index hospitalization. We assessed readmission rates following treatment for American Association for the Surgery of Trauma (AAST) Grade 3 and 4 renal injury using the Comprehensive Hospital Abstract Reporting System (CHARS). We evaluated all patients with AAST Grade 3 and 4 renal injuries admitted to Harborview Medical Center (HMC) between 1998 and 2010, the only Level 1 trauma center in Washington state. Grade 4 renal injuries were stratified by collecting system laceration (CSL) or segmental vascular injury. Data were abstracted from the CHARS database for readmissions to any Washington state hospital within 6 months of renal injury. Clinical variables, diagnoses, and procedures were queried based on DRG International Classification of Diseases-9th Rev. codes. A total of 477 Grade 3 and 159 Grade 4 renal injuries were initially treated at HMC. On admission, 111 patients required intervention: 75 (16%) of 477 Grade 3 and 36 (23%) of 159 Grade 4 injuries. Within 6 months of index hospitalization, 86 (18%) of 477 Grade 3 and 38 (24%) of 159 Grade 4 patients were readmitted to any Washington state hospital. Eighty percent of Grade 3 injuries and 66% of Grade 4 injuries returned to HMC compared with secondary hospitals (p = 0.08). At readmission, 19 (22%) of 86 Grade 3 and 16 (42%) of 38 Grade 4 injuries had a urologic diagnosis. Subsequent procedural intervention was required on readmission in 6 (7%) of 86 Grade 3 and 5 (13%) of 38 Grade 4 renal injuries (all CSL injuries). A subset of patients treated for Grade 3 and 4 renal trauma will be readmitted for further management. While urologic diagnoses and additional procedures may be low overall, readmission to outside hospitals may preclude accurate determination of renal trauma outcomes. Based on these data, patients with Grade 4 CSL injuries seem to be at the highest risk for readmission and to require a subsequent urologic procedure. Prognostic/epidemiologic study, level III.
Anderson, Ross E.; Fiander, Michelle; McFarland, Mary M.; Stoddard, Gregory J.; Hotaling, James M.; Myers, Jeremy B.
2018-01-01
Background Collecting system injury and urinary extravasation is an important yet understudied aspect of renal trauma. We aimed to examine the incidence of urinary extravasation and also the rates of ureteral stenting after high-grade renal trauma (HGRT) in adults. Methods A search strategy was developed to search Ovid Medline, Embase, CINAHL, and Cochrane Library. Two reviewers screened titles and abstracts, followed by full-text review of the relevant publications. Studies were included if they indicated the number of patients with HGRT [the American Association for the Surgery of Trauma (AAST) grades III–IV or equivalents] and number of patients with urinary extravasation. A descriptive meta-analysis of binary proportions was performed with random-effects model to calculate the incidence of urinary extravasation and rates of ureteral stenting. Results After screening, 24 and 20 studies were included for calculating urinary extravasation and stenting rates, respectively. Most studies involved blunt injury and were retrospective single-center case series. Incidence of urinary extravasation was 29% (95% CI: 17–42%) after HGRT (grade III–V), and 51% (95% CI: 38–64%) when only grade IV–V injuries were combined. Overall, 29% (95% CI: 22–36%) of patients with urinary extravasation underwent ureteral stenting. Conclusions Approximately 30% of patients with HGRT are diagnosed with urinary extravasation and 29% of those with urinary extravasation undergo ureteral stenting. Understanding the rate of urinary extravasation and interventions is the first step in creating a prospective trial designed to demonstrate when ureteral stenting and aggressive management of urinary extravasation is needed. PMID:29928614
Keihani, Sorena; Anderson, Ross E; Fiander, Michelle; McFarland, Mary M; Stoddard, Gregory J; Hotaling, James M; Myers, Jeremy B
2018-05-01
Collecting system injury and urinary extravasation is an important yet understudied aspect of renal trauma. We aimed to examine the incidence of urinary extravasation and also the rates of ureteral stenting after high-grade renal trauma (HGRT) in adults. A search strategy was developed to search Ovid Medline, Embase, CINAHL, and Cochrane Library. Two reviewers screened titles and abstracts, followed by full-text review of the relevant publications. Studies were included if they indicated the number of patients with HGRT [the American Association for the Surgery of Trauma (AAST) grades III-IV or equivalents] and number of patients with urinary extravasation. A descriptive meta-analysis of binary proportions was performed with random-effects model to calculate the incidence of urinary extravasation and rates of ureteral stenting. After screening, 24 and 20 studies were included for calculating urinary extravasation and stenting rates, respectively. Most studies involved blunt injury and were retrospective single-center case series. Incidence of urinary extravasation was 29% (95% CI: 17-42%) after HGRT (grade III-V), and 51% (95% CI: 38-64%) when only grade IV-V injuries were combined. Overall, 29% (95% CI: 22-36%) of patients with urinary extravasation underwent ureteral stenting. Approximately 30% of patients with HGRT are diagnosed with urinary extravasation and 29% of those with urinary extravasation undergo ureteral stenting. Understanding the rate of urinary extravasation and interventions is the first step in creating a prospective trial designed to demonstrate when ureteral stenting and aggressive management of urinary extravasation is needed.
Top Surgery in Transgender Men: How Far Can You Push the Envelope?
Bluebond-Langner, Rachel; Berli, Jens U; Sabino, Jennifer; Chopra, Karan; Singh, Devinder; Fischer, Beverly
2017-04-01
The authors present their grading scale and the outcomes of the largest cohort of top surgery published to date. Application of this grading system can help determine which patients will benefit from a subcutaneous mastectomy with free nipple graft versus a circumareolar technique, with the primary endpoint being need for aesthetic revisions. The authors reviewed their database of transgender males who underwent bilateral mastectomy between 2006 and 2015. Data collected included age, body mass index, American Society of Anesthesiologists class, smoking, diabetes, testosterone use, months of social transition, technique used, postoperative complications, and need for revision. Two techniques were used, circumareolar incision and free nipple graft technique. Between 2006 and 2015, 1686 consecutive mastectomies were performed on 843 patients. Of those, 548 patients were excluded because of inadequate follow-up. Of the 295 included, 109 were treated using a circumareolar incision and 186 were treated using a free nipple graft technique. There was no statistically significant difference in complications between the two groups; however, there was a statistically significant difference in the rate of aesthetic revisions in the grade 2B circumareolar incision group (34 percent versus 8.8 percent). The authors' outcomes are comparable to the literature, and demonstrate that these procedures can safely be performed in an outpatient setting. The authors' grading scale classifies patients and helps the surgeon select a surgical technique. The authors show a statistical difference in rates of aesthetic revisions in Fischer grade 2B patients when a circumareolar incision is selected over a free nipple graft technique. Therapeutic, III.
Performance evaluation of image-intensifier-TV fluoroscopy systems
NASA Astrophysics Data System (ADS)
van der Putten, Wilhelm J.; Bouley, Shawn
1995-05-01
Through use of a computer model and an aluminum low contrast phantom developed in-house, a method has been developed which is able to grade the imaging performance of fluoroscopy systems through use of a variable, K. This parameter was derived from Rose's model of image perception and is here used as a figure of merit to grade fluoroscopy systems. From Rose's model for an ideal system, a typical value of K for the perception of low contrast details should be between 3 and 7, assuming threshold vision by human observers. Thus, various fluoroscopy systems are graded with different values of K, with a lower value of K indicating better imaging performance of the system. A series of fluoroscopy systems have been graded where the best system produces a value in the low teens, while the poorest systems produce a value in the low twenties. Correlation with conventional image quality measurements is good and the method has the potential for automated assessment of image quality.
Subchondral bone histology and grading in osteoarthritis
Aho, Olli-Matti; Finnilä, Mikko; Thevenot, Jerome; Saarakkala, Simo; Lehenkari, Petri
2017-01-01
Objective Osteoarthritis (OA) has often regarded as a disease of articular cartilage only. New evidence has shifted the paradigm towards a system biology approach, where also the surrounding tissue, especially bone is studied more vigorously. However, the histological features of subchondral bone are only poorly characterized in current histological grading scales of OA. The aim of this study is to specifically characterize histological changes occurring in subchondral bone at different stages of OA and propose a simple grading system for them. Design 20 patients undergoing total knee replacement surgery were randomly selected for the study and series of osteochondral samples were harvested from the tibial plateaus for histological analysis. Cartilage degeneration was assessed using the standardized OARSI grading system, while a novel four-stage grading system was developed to illustrate the changes in subchondral bone. Subchondral bone histology was further quantitatively analyzed by measuring the thickness of uncalcified and calcified cartilage as well as subchondral bone plate. Furthermore, internal structure of calcified cartilage-bone interface was characterized utilizing local binary patterns (LBP) based method. Results The histological appearance of subchondral bone changed drastically in correlation with the OARSI grading of cartilage degeneration. As the cartilage layer thickness decreases the subchondral plate thickness and disorientation, as measured with LBP, increases. Calcified cartilage thickness was highest in samples with moderate OA. Conclusion The proposed grading system for subchondral bone has significant relationship with the corresponding OARSI grading for cartilage. Our results suggest that subchondral bone remodeling is a fundamental factor already in early stages of cartilage degeneration. PMID:28319157
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lian, T; Whalen, M T; Wong, L
2004-11-30
The effects of oxide film on the corrosion behavior of Titanium Grade 7 (0.12-0.25% Pd) in fluoride-containing NaCl brines have been investigated. With the presence of a 0.6 {micro}m thick oxide layer, the annealed Ti grade 7 exhibited a significant improvement on the anodic polarization behavior. However, the oxide film did not demonstrate sustainable corrosion resistance in fluoride-containing solutions.
Development of optimized, graded-permeability axial groove heat pipes
NASA Technical Reports Server (NTRS)
Kapolnek, Michael R.; Holmes, H. Rolland
1988-01-01
Heat pipe performance can usually be improved by uniformly varying or grading wick permeability from end to end. A unique and cost effective method for grading the permeability of an axial groove heat pipe is described - selective chemical etching of the pipe casing. This method was developed and demonstrated on a proof-of-concept test article. The process improved the test article's performance by 50 percent. Further improvement is possible through the use of optimally etched grooves.
Grading NASA's Solar System Exploration Program: A Midterm Report
NASA Technical Reports Server (NTRS)
2008-01-01
The Committee on Assessing the Solar System Exploration Program has reviewed NASA's progress to date in implementing the recommendations made in the National Research Council's (NRC's) solar system exploration decadal survey covering the period 2003-2013, New Frontiers in the Solar System, and in its Mars Architecture report, Assessment of NASA s Mars Architecture 2007-2016. The committee assessed NASA's progress with respect to each individual recommendation in these two reports, assigning an academic-style grade, explaining the rationale for the grade and trend, and offering recommendations for improvement. The committee generally sought to develop recommendations in cases where it determined that the grade, the trend, or both were worrisome and that the achievement of a decadal survey recommendation would require some kind of corrective action on NASA's part. This usually meant that the committee sought to offer a recommendation when the grade was a "C" or lower. However, the committee did offer recommendations in connection with some higher grades when it believed that minor corrective action was possible and desirable. More importantly, the committee did not offer recommendations for some of the activities given lower grades, particularly in the enabling technologies area (Chapter 6), because the committee determined that only the restoration of funding and the development of a strategic technology development program would solve these problems.
Lee, Ho Yun; Park, Moon Suh; Byun, Jae Yong; Chung, Ji Hyun; Na, Se Young; Yeo, Seung Geun
2013-09-01
We have analyzed the correlation between the House-Brackmann (HB) scale and Facial Nerve Grading System 2.0 (FNGS 2.0) in patients with Bell palsy, and evaluated the usefulness of the new grading system. Sixty patients diagnosed with Bell palsy from May 2009 to December 2010 were evaluated using the HB scale and FNGS 2.0 scale during their initial visit, and after 3 and 6 weeks and 3 months. The overall intraclass correlation coefficient (ICC) was 0.908 (P=0.000) and the Spearman correlation coefficient (SCC) was 0.912 (P<0.05). ICC and SCC displayed differences over time, being 0.604 and 0.626, respectively, at first visit; 0.834 and 0.843, respectively, after 3 weeks; 0.844 and 0.848, respectively, after 6 weeks; and 0.808 and 0.793, respectively, after 3 months. There was a significant difference in full recovery, depending on the scale used (HB, P=0.000; FNGS 2.0, P<0.05). The exact agreements between regional assessment and FNGS 2.0 for the mouth, eyes, and brow were 72%, 63%, and 52%, respectively. FNGS 2.0 shows moderate agreement with HB grading. Regional assessment, rather than HB grading, yields stricter evaluation, resulting in better prognosis and determination of grade.
Zhou, Changchun; Deng, Congying; Chen, Xuening; Zhao, Xiufen; Chen, Ying; Fan, Yujiang; Zhang, Xingdong
2015-08-01
Functionally graded materials (FGM) open the promising approach for bone tissue repair. In this study, a novel functionally graded hydroxyapatite (HA) bioceramic with micrograin and nanograin structure was fabricated. Its mechanical properties were tailored by composition of micrograin and nanograin. The dynamic mechanical analysis (DMA) indicated that the graded HA ceramics had similar mechanical property compared to natural bones. Their cytocompatibility was evaluated via fluorescent microscopy and MTT colorimetric assay. The viability and proliferation of rabbit bone marrow mesenchymal stem cells (BMSCs) on ceramics indicated that this functionally graded HA ceramic had better cytocompatibility than conventional HA ceramic. This study demonstrated that functionally graded HA ceramics create suitable structures to satisfy both the mechanical and biological requirements of bone tissues. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zhang, G Y; Ahmed, N; Riley, C; Oliva, K; Barker, G; Quinn, M A; Rice, G E
2005-01-17
The peroxisome proliferator-activated receptors (PPARs) belong to a subclass of nuclear hormone receptor that executes important cellular transcriptional functions. Previous studies have demonstrated the expression of PPARgamma in several tumours including colon, breast, bladder, prostate, lung and stomach. This study demonstrates the relative expression of PPARgamma in normal ovaries and different pathological grades of ovarian tumours of serous, mucinous, endometrioid, clear cell and mixed subtypes. A total of 56 ovarian specimens including 10 normal, eight benign, 10 borderline, seven grade 1, nine grade 2 and 12 grade 3 were analysed using immunohistochemistry. Immunoreactive PPARgamma was not expressed in normal ovaries. Out of eight benign and 10 borderline tumours, only one tumour in each group showed weak cytoplasmic PPARgamma expression. In contrast, 26 out of 28 carcinomas studied were positive for PPARgamma expression with staining confined to cytoplasmic and nuclear regions. An altered staining pattern of PPARgamma was observed in high-grade ovarian tumours with PPARgamma being mostly localized in the nuclei with little cytoplasmic immunoreactivity. On the other hand, predominant cytoplasmic staining was observed in lower-grade tumours. Significantly increased PPARgamma immunoreactivity was observed in malignant ovarian tumours (grade 1, 2 and 3) compared to benign and borderline tumours (chi2 = 48.80, P < 0.001). Western blot analyses showed significant elevation in the expression of immunoreactive PPARgamma in grade 3 ovarian tumours compared with that of normal ovaries and benign ovarian tumours (P < 0.01). These findings suggest an involvement of PPARgamma in the onset and development of ovarian carcinoma and provide an insight into the regulation of this molecule in the progression of the disease.
Spacesuit Data Display and Management System
NASA Technical Reports Server (NTRS)
Hall, David G.; Sells, Aaron; Shah, Hemal
2009-01-01
A prototype embedded avionics system has been designed for the next generation of NASA extra-vehicular-activity (EVA) spacesuits. The system performs biomedical and other sensor monitoring, image capture, data display, and data transmission. An existing NASA Phase I and II award winning design for an embedded computing system (ZIN vMetrics - BioWATCH) has been modified. The unit has a reliable, compact form factor with flexible packaging options. These innovations are significant, because current state-of-the-art EVA spacesuits do not provide capability for data displays or embedded data acquisition and management. The Phase 1 effort achieved Technology Readiness Level 4 (high fidelity breadboard demonstration). The breadboard uses a commercial-grade field-programmable gate array (FPGA) with embedded processor core that can be upgraded to a space-rated device for future revisions.
Advanced Flue Gas Desulfurization (AFGD) Demonstration Project, A DOE Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
National Energy Technology Laboratory
2001-08-31
The AFGD process as demonstrated by Pure Air at the Bailly Station offers a reliable and cost-effective means of achieving a high degree of SO{sub 2} emissions reduction when burning high-sulfur coals. Many innovative features have been successfully incorporated in this process, and it is ready for widespread commercial use. The system uses a single-loop cocurrent scrubbing process with in-situ oxidation to produce wallboard-grade gypsum instead of wet sludge. A novel wastewater evaporation system minimizes effluents. The advanced scrubbing process uses a common absorber to serve multiple boilers, thereby saving on capital through economies of scale. Major results of themore » project are: (1) SO{sub 2} removal of over 94 percent was achieved over the three-year demonstration period, with a system availability exceeding 99.5 percent; (2) a large, single absorber handled the combined flue gas of boilers generating 528 MWe of power, and no spares were required; (3) direct injection of pulverized limestone into the absorber was successful; (4) Wastewater evaporation eliminated the need for liquid waste disposal; and (5) the gypsum by-product was used directly for wallboard manufacture, eliminating the need to dispose of waste sludge.« less
Code of Federal Regulations, 2013 CFR
2013-10-01
... reporting of unsafe conditions at highway-rail and pathway grade crossings. 234.303 Section 234.303... at Highway-Rail and Pathway Grade Crossings § 234.303 Emergency notification systems for telephonic reporting of unsafe conditions at highway-rail and pathway grade crossings. (a) Duty of dispatching railroad...
Code of Federal Regulations, 2014 CFR
2014-10-01
... reporting of unsafe conditions at highway-rail and pathway grade crossings. 234.303 Section 234.303... at Highway-Rail and Pathway Grade Crossings § 234.303 Emergency notification systems for telephonic reporting of unsafe conditions at highway-rail and pathway grade crossings. (a) Duty of dispatching railroad...
Code of Federal Regulations, 2012 CFR
2012-10-01
... reporting of unsafe conditions at highway-rail and pathway grade crossings. 234.303 Section 234.303... at Highway-Rail and Pathway Grade Crossings § 234.303 Emergency notification systems for telephonic reporting of unsafe conditions at highway-rail and pathway grade crossings. (a) Duty of dispatching railroad...
Plus and Minus Grading Options: Toward Accurate Student Performance Evaluations.
ERIC Educational Resources Information Center
California Community Colleges, Sacramento. Academic Senate.
Although both the University of California and the California State University systems have the option to use plus or minus grades in student evaluations, the Board of Governors of the California Community Colleges (CCC) does not allow the use of such a grading system. Since 1985, the CCC's Academic Senate has lobbied the Board to allow local…
Economics of Grading and Sorting Pallet Parts
Daniel L. Schmoldt; John A. McLeod; Philip A. Araman
1993-01-01
Before trying to develop an automated inspection system for pallet part grading we analyzed the economics of such a system. Our results suggest that higher quality pallets produced by grading and sorting pallet parts would be attractive to both manufacturers and their customers, who would have to pay increased prices for higher quality pallets. Reductions in cost-per-...
Resource Allocation Patterns and Student Achievement
ERIC Educational Resources Information Center
James, Lori; Pate, James; Leech, Donald; Martin, Ellice; Brockmeier, Lantry; Dees, Elizabeth
2011-01-01
This quantitative research study was designed to examine the relationship between system resource allocation patterns and student achievement, as measured by eighth grade Criterion-Referenced Competency Test (CRCT) mathematics, eighth grade CRCT reading, eleventh grade Georgia High School Graduation Test (GHSGT) mathematics, eleventh grade and…
49 CFR Appendix A to Part 222 - Approved Supplementary Safety Measures
Code of Federal Regulations, 2014 CFR
2014-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION USE OF LOCOMOTIVE HORNS AT PUBLIC HIGHWAY-RAIL GRADE... safety measures (SSMs) that may be installed at highway-rail grade crossings within quiet zones for risk... research and demonstration projects are completed and data is gathered and refined. Sections B and C govern...
49 CFR Appendix A to Part 222 - Approved Supplementary Safety Measures
Code of Federal Regulations, 2012 CFR
2012-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION USE OF LOCOMOTIVE HORNS AT PUBLIC HIGHWAY-RAIL GRADE... safety measures (SSMs) that may be installed at highway-rail grade crossings within quiet zones for risk... research and demonstration projects are completed and data is gathered and refined. Sections B and C govern...
49 CFR Appendix A to Part 222 - Approved Supplementary Safety Measures
Code of Federal Regulations, 2011 CFR
2011-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION USE OF LOCOMOTIVE HORNS AT PUBLIC HIGHWAY-RAIL GRADE... safety measures (SSMs) that may be installed at highway-rail grade crossings within quiet zones for risk... research and demonstration projects are completed and data is gathered and refined. Sections B and C govern...
49 CFR Appendix A to Part 222 - Approved Supplementary Safety Measures
Code of Federal Regulations, 2013 CFR
2013-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION USE OF LOCOMOTIVE HORNS AT PUBLIC HIGHWAY-RAIL GRADE... safety measures (SSMs) that may be installed at highway-rail grade crossings within quiet zones for risk... research and demonstration projects are completed and data is gathered and refined. Sections B and C govern...
Academic Freedom and Grading: The Role of Placement Providers
ERIC Educational Resources Information Center
Martin, Ian
2011-01-01
Placement providers can be successfully involved in assessing students. This is demonstrated in the Monash University Faculty of Information Technology Cooperative Education Program. Students are thoroughly prepared for their placements and industry supervisors receive written assessment guidelines. Not one student has been awarded a pass grade by…
The Academic Ethic and College Grades: Does Hard Work Help Students To "Make the Grade"?
ERIC Educational Resources Information Center
Rau, William; Durand, Ann
2000-01-01
Demonstrates how "academic ethic" (a student world view that emphasizes diligent, daily, and sober study) can be operationalized and measured. Provides evidence for its existence among students at Illinois State University. Finds a relationship between methodical, disciplined study and academic performance. (Contains references.) (CMK)
The Predictive Validity of the Metropolitan Readiness Tests, 1976 Edition.
ERIC Educational Resources Information Center
Nagle, Richard J.
1979-01-01
A sample of 176 first-grade children was tested on the Metropolitan Readiness Tests, 1976 Edition (MRT), during the initial month of school and was retested eight months later on the Stanford Achievement Test. Results demonstrated substantial validity of the MRT for predicting first-grade achievement. (Author/CTM)
ERIC Educational Resources Information Center
Eshleman, Winston Hull
Compared were programed materials and conventional methods for teaching two units of eighth grade science. Programed materials used were linear programed books requiring constructed responses. The conventional methods included textbook study, written exercises, lectures, discussions, demonstrations, experiments, chalkboard drawings, films,…
Course Sequencing in the Communication Curriculum: A Case Study
ERIC Educational Resources Information Center
Richards, Adam S.
2012-01-01
This case study of the Department of Communication at the University of Maryland demonstrates the need to consider course sequencing in the communication curriculum. The investigation assessed whether the order in which undergraduates took courses predicted grade performance. Students' (N = 6,166) grade data from earlier courses were used to…
Investigating Our Environment. Science: Grade 6.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Bureau of Curriculum Development.
Intended mainly for use in the intermediate grades, this document provides demonstrations, field trips and laboratory experiences designed to help students investigate the role that people play in problems associated with environmental quality, pollution, and ecology in general. The book was developed as an alternative program to the regular sixth…
Advantages and Disadvantages of Weighted Grading. Research Brief
ERIC Educational Resources Information Center
Walker, Karen
2004-01-01
What are the advantages and disadvantages of weighted grading? The primary purpose of weighted grading has been to encourage high school students to take more rigorous courses. This effort is then acknowledged by more weight being given to the grade for a specified class. There are numerous systems of weighted grading cited in the literature from…
Evaluating Sermons: The Function of Grades in Teaching Preaching
ERIC Educational Resources Information Center
Helsel, Carolyn Browning
2017-01-01
What are grades doing in a homiletics classroom? This article traces the function of grades through the broader history of the educational system in the United States and then makes suggestions for how grades can be used more effectively in teaching preaching. Beginning in the nineteenth century, teachers used grades to rank and motivate students,…
Face pose tracking using the four-point algorithm
NASA Astrophysics Data System (ADS)
Fung, Ho Yin; Wong, Kin Hong; Yu, Ying Kin; Tsui, Kwan Pang; Kam, Ho Chuen
2017-06-01
In this paper, we have developed an algorithm to track the pose of a human face robustly and efficiently. Face pose estimation is very useful in many applications such as building virtual reality systems and creating an alternative input method for the disabled. Firstly, we have modified a face detection toolbox called DLib for the detection of a face in front of a camera. The detected face features are passed to a pose estimation method, known as the four-point algorithm, for pose computation. The theory applied and the technical problems encountered during system development are discussed in the paper. It is demonstrated that the system is able to track the pose of a face in real time using a consumer grade laptop computer.
Hernandez, Matthew C; Polites, Stephanie F; Aho, Johnathon M; Haddad, Nadeem N; Kong, Victor Y; Saleem, Humza; Bruce, John L; Laing, Grant L; Clarke, Damian L; Zielinski, Martin D
2018-01-01
To assess whether the American Association for the Surgery of Trauma (AAST) grading system accurately corresponds with appendicitis outcomes in a US pediatric population. This single-institution retrospective review included patients <18 years of age (n = 331) who underwent appendectomy for acute appendicitis from 2008 to 2012. Demographic, clinical, procedural, and follow-up data (primary outcome was measured as Clavien-Dindo grade of complication severity) were abstracted. AAST grades were generated based on intraoperative findings. Summary, univariate, and multivariable regression analyses were performed to compare AAST grade and outcomes. Overall, 331 patients (46% female) were identified with a median age of 12 (IQR, 8-15) years. Appendectomy was laparoscopic in 90% and open in 10%. AAST grades included: Normal (n = 13, 4%), I (n = 152, 46%), II (n = 90, 27%), III (n = 43, 13%), IV (n = 24 7.3%), and V (n = 9 2.7%). Increased AAST grade was associated with increased Clavien-Dindo severity, P =.001. The overall complication rate was 13.6% and was comprised by superficial surgical site infection (n = 13, 3.9%), organ space infection (n = 15, 4.5%), and readmission (n = 17, 5.1%). Median duration of stay increased with AAST grade (P < .0001). Nominal logistic regression identified the following as predictors of any complication (P < .05): AAST grade and febrile temperature at admission. The AAST appendicitis grading system is valid in a single-institution pediatric population. Increasing AAST grade incrementally corresponds with patient outcomes including increased risk of complications and severity of complications. Determination of the generalizability of this grading system is required. Copyright © 2017 Elsevier Inc. All rights reserved.
An Investigation of the Generalizability of Medical School Grades.
Kreiter, Clarence D; Ferguson, Kristi J
2016-01-01
Construct/Background: Medical school grades are currently unstandardized, and their level of reliability is unknown. This means their usefulness for reporting on student achievement is also not well documented. This study investigates grade reliability within 1 medical school. Generalizability analyses are conducted on grades awarded. Grades from didactic and clerkship-based courses were treated as 2 levels of a fixed facet within a univariate mixed model. Grades from within the 2 levels (didactic and clerkship) were also entered in a multivariate generalizability study. Grades from didactic courses were shown to produce a highly reliable mean score (G = .79) when averaged over as few as 5 courses. Although the universe score correlation between didactic and clerkship courses was high (r = .80), the clerkship courses required almost twice as many grades to reach a comparable level of reliability. When grades were converted to a Pass/Fail metric, almost all information contained in the grades was lost. Although it has been suggested that the imprecision of medical school grades precludes their use as a reliable indicator of student achievement, these results suggest otherwise. While it is true that a Pass/Fail system of grading provides very little information about a student's level of performance, a multi-tiered grading system was shown to be a highly reliable indicator of student achievement within the medical school. Although grades awarded during the first 2 didactic years appear to be more reliable than clerkship grades, both yield useful information about student performance within the medical college.
Cannell, R C; Belk, K E; Tatum, J D; Wise, J W; Chapman, P L; Scanga, J A; Smith, G C
2002-05-01
Objective quantification of differences in wholesale cut yields of beef carcasses at plant chain speeds is important for the application of value-based marketing. This study was conducted to evaluate the ability of a commercial video image analysis system, the Computer Vision System (CVS) to 1) predict commercially fabricated beef subprimal yield and 2) augment USDA yield grading, in order to improve accuracy of grade assessment. The CVS was evaluated as a fully installed production system, operating on a full-time basis at chain speeds. Steer and heifer carcasses (n = 296) were evaluated using CVS, as well as by USDA expert and online graders, before the fabrication of carcasses into industry-standard subprimal cuts. Expert yield grade (YG), online YG, CVS estimated carcass yield, and CVS measured ribeye area in conjunction with expert grader estimates of the remaining YG factors (adjusted fat thickness, percentage of kidney-pelvic-heart fat, hot carcass weight) accounted for 67, 39, 64, and 65% of the observed variation in fabricated yields of closely trimmed subprimals. The dual component CVS predicted wholesale cut yields more accurately than current online yield grading, and, in an augmentation system, CVS ribeye measurement replaced estimated ribeye area in determination of USDA yield grade, and the accuracy of cutability prediction was improved, under packing plant conditions and speeds, to a level close to that of expert graders applying grades at a comfortable rate of speed offline.
Bruxism defined and graded: an international consensus.
Lobbezoo, F; Ahlberg, J; Glaros, A G; Kato, T; Koyano, K; Lavigne, G J; de Leeuw, R; Manfredini, D; Svensson, P; Winocur, E
2013-01-01
To date, there is no consensus about the definition and diagnostic grading of bruxism. A written consensus discussion was held among an international group of bruxism experts as to formulate a definition of bruxism and to suggest a grading system for its operationalisation. The expert group defined bruxism as a repetitive jaw-muscle activity characterised by clenching or grinding of the teeth and/or by bracing or thrusting of the mandible. Bruxism has two distinct circadian manifestations: it can occur during sleep (indicated as sleep bruxism) or during wakefulness (indicated as awake bruxism). For the operationalisation of this definition, the expert group proposes a diagnostic grading system of 'possible', 'probable' and 'definite' sleep or awake bruxism. The proposed definition and grading system are suggested for clinical and research purposes in all relevant dental and medical domains. © 2012 Blackwell Publishing Ltd.
Promoting Chemistry at the Elementary Level: A Low-Maintenance Program of Chemical Demonstrations.
ERIC Educational Resources Information Center
Louters, Larry L.; Huisman, Richard D.
1999-01-01
Presents a chemical demonstration program designed to support elementary science education in which fifth- and sixth-grade students visit a college campus to watch chemical demonstrations performed by a professor. Contains suggestions for program set-up and references for demonstrations to use. (WRM)
Accountability and Grade Inflation in a Rural School.
ERIC Educational Resources Information Center
Goodwin, Deborah Hayes; Holman, David M.
In an effort to hold schools accountable, Arkansas added grade inflation into the accountability system. The Arkansas Legislature mandated that the Arkansas Department of Education identify high schools with "statistically significant variance" between students' grade point averages (GPAs) and ACT performances. A grade inflation index…
Design and characterization of dielectric subwavelength focusing lens with polarization dependence
NASA Astrophysics Data System (ADS)
Kim, Sung W.; Pang, Lin; Fainman, Yeshaiahu
2016-03-01
We introduce and develop design, fabrication and characterization methodology for engineering the effective refractive index of a composite dielectric planar surface created by controlling the density of deeply subwavelength low index nanoholes (e.g., air) in a high index dielectric layer (e.g., Si). The nanoscale properties of a composite dielectric layer allows for full control of the optical wavefront phase by designing arbitrary space-variant refractive index profiles. We present the composite dielectric metasurface microlens exploiting symmetric design to achieve polarization invariant impulse response, and use asymmetric design to demonstrate polarization sensitive impulse response of the lens. This composite dielectric layers lenses were fabricated by patterning nanohole distributions on a dielectric surface and etching to submicron depths. Our dielectric microlens with asymmetric distribution of neff (neff x ≠ neff y) demonstrates a graded index lens with polarization dependent focusing with of 32um and 22 um for linearly x- and y-polarized light, respectively operating at a wavelength of λ = 1550nm. We also show numerically and demonstrate experimentally achromatic performance of the devices operating in the wavelength range of 1500nm - 1900nm with FWHM of the focal spots of about 4um. Namely, we have constructed a graded index lens that can overcome diffraction effects even when aperture/wavelength (D/λ) is smaller than 40. The demonstrated novel approach to engineer dielectric composite nanosurfaces has the potential to realize arbitrary phase functions with minimal insertion loss, submicron thickness and miniaturization to reduce element size and weight, and may have a significant impact on numerous miniature imaging systems applications.
Utility of the distal ureteral diameter on VCUG for grading VUR.
Cooper, C S; Alexander, S E; Kieran, K; Storm, D W
2015-08-01
For children with VUR the grade of vesicoureteral reflux (VUR) remains one of the most predictive factors relative to outcome. However, the subjective nature of the currently accepted international reflux grading system (IRGS) leads to inter-observer variation. The potential of a direct measurement of the distal ureter on the voiding cystourethrogram (VCUG) normalized to the L1-L3 vertebral body distance (ureteral diameter ratio - UDR) to augment the ability of IRGS to predict the ultimate clinical outcome has previously been reported in a group of 79 children. The goal of this current review was to expand the previous review and analysis in order to assess the predictive ability of the UDR with respect to earlier clinical outcome and to compare this ability to the grade of VUR while controlling for other variables. This retrospective review of the VCUG of 157 children with primary VUR included 124 girls and 33 boys with a mean age of 2.7 years (7 days-13.5 years). In addition to the UDR, other variables that were analyzed included: age, gender, VUR grade, laterality, history of febrile urinary tract infection (UTI) or multiple UTIs prior to diagnosis, and bladder-bowel dysfunction (BBD). Cox regression analysis was utilized and a generalized logit model for 2-year outcome was also fitted to compare the effect of UDR and VUR grade using Wald Chi-squared analysis. The 2-year outcome after the VCUG was defined as: persistent VUR (47%), spontaneous VUR resolution (15%), or operative intervention (38%). Reasons for operative intervention included: breakthrough UTI (1/3), decreased relative renal function associated with renal scarring (1/3), and failure to resolve, along with parental preference (1/3). Increasing UDR was significantly associated with increased grade and a decreased chance of spontaneous resolution. It was unlikely for a child with Grade 4, 3, or 2 VUR to have spontaneous resolution if their UDR was above 0.25, 0.3, or 0.35, respectively. In addition, higher grades of VUR, older age, and bilateral VUR were significantly associated with failure to spontaneously resolve VUR. As seen in Figure, children with grades 2 and 3 VUR less than 2 years of age had a better chance of spontaneous resolution with a larger UDR than children 2 years of age or older. When adjusting for age, grade, laterality and multiple UTIs as covariates, each unit increase of UDR of 0.1 was significantly associated with either persistent VUR (OR = 1.73, 95% CI = 1.02-2.95, P = 0.043) or the need for surgical intervention (OR = 2.40, 95% CI = 1.39-4.17, P = 0.002) compared to spontaneous resolution. When testing the effect of UDR and grade of reflux in the same model, UDR was noted to have a larger effect on predicting failure to spontaneously resolve VUR than grade (Wald Chi-Squared 13.6; P = 0.001 vs 3.62; P = 0.46, respectively). The UDR is a readily available objective measurement on the VCUG that has demonstrated ability to enhance the International Reflux Grading System. Limitations of the current review include operative intervention in 12% of the children for failure to improve or resolve VUR. This surgical intervention inhibits determination of spontaneous resolution rates. The findings in this study reflect those in a series of children from a single institution and, therefore, may be impacted by clinical practice bias and geographic variations. Subsequent multi-institutional studies could further define the potential of UDR as either an independent or additive predictive factor for grading VUR that will further permit individualized patient management. In this single institution series, UDR was highly correlated with VUR grade; however, UDR proved more predictive of spontaneous resolution, persistence, or operative intervention than grade. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Bergknut, Niklas; Grinwis, Guy; Pickee, Emile; Auriemma, Edoardo; Lagerstedt, Anne-Sofie; Hagman, Ragnvi; Hazewinkel, Herman A W; Meij, Björn P
2011-07-01
To evaluate the reliability of the Thompson system for use in grading the gross pathological changes of intervertebral disk (IVD) degeneration in dogs and to investigate the agreement between gross pathological findings and low-field (0.2-T) magnetic resonance imaging (MRI) findings. Vertebral columns from cadavers of 19 dogs of various ages, breeds, and origins. 182 intervertebral segments were collected from 19 canine cadavers. Sagittal T2-weighted MRI of the T11 through S1 portion of the vertebral column was performed within 24 hours after the dogs were euthanized. The vertebral columns were subsequently divided in the midsagittal plane, and high-resolution photographs were obtained of each intervertebral segment (end plate-disk-end plate). The MRI images and photographs were graded separately in a blinded manner by 4 observers who used both Pfirrmann and Thompson grading criteria. The interobserver agreement for Thompson scores ranged from 0.76 to 0.88, and the intraobserver agreement ranged from 0.88 to 0.94 (Cohen weighted κ analysis). Agreement between scores for the Pfirrmann and Thompson grading criteria was κ = 0.70. Grading of IVD degeneration in dogs by use of the Thompson system resulted in high interobserver and intraobserver agreement, and scores for the Thompson system had substantial agreement with low-field MRI findings graded by use of the Pfirrmann system. This suggested that low-field MRI can be used to diagnose IVD degeneration in dogs.
Mazeh, Haggi; Samet, Yacov; Abu-Wasel, Bassam; Beglaibter, Nahum; Grinbaum, Ronit; Cohen, Tzeela; Pinto, Meir; Hamburger, Tamar; Freund, Herbert R; Nissan, Aviram
2009-03-01
Uniform and accurate reporting of surgical complications is the basis for quality control. We developed a computerized system for reporting and grading surgical complications in colorectal surgery. This study was conducted to evaluate this computerized reporting system. A retrospective chart review was conducted of all surgical complications in patients who underwent resection of the colon or rectum at our institution between the years 1999 and 2004 (n = 408). All complications were recorded using the computerized reporting system and compared with complications reported in the literature. Elective operations were performed in 75.7% of patients, and 24.3% required emergency operations. Of the 408 patients in the study, 239 (58.6%) had an uneventful recovery without complications. At least 1 complication was recorded in 169 (41.4%) patients. Grades 1 and 2 complications were recorded in 83 (20.3%) and 105 (25.7%) patients, respectively, requiring observation or medical treatment only, and 59 patients (14.5%) had grades 3 to 5 complications. The three leading complications were surgical site infection, intraabdominal abscess, and hemorrhage requiring blood transfusion. The grades 3 to 5 complication rate was within the range described in the literature, and the rate of grades 1 and 2 complications was substantially higher. These grades 1 and 2 complications were associated with a substantially longer hospital stay. This novel complication reporting system was found feasible and proved to have a higher sensitivity for recording minor but meaningful complications that tend to prolong hospital stay.
The SCHEIE Visual Field Grading System
Sankar, Prithvi S.; O’Keefe, Laura; Choi, Daniel; Salowe, Rebecca; Miller-Ellis, Eydie; Lehman, Amanda; Addis, Victoria; Ramakrishnan, Meera; Natesh, Vikas; Whitehead, Gideon; Khachatryan, Naira; O’Brien, Joan
2017-01-01
Objective No method of grading visual field (VF) defects has been widely accepted throughout the glaucoma community. The SCHEIE (Systematic Classification of Humphrey visual fields-Easy Interpretation and Evaluation) grading system for glaucomatous visual fields was created to convey qualitative and quantitative information regarding visual field defects in an objective, reproducible, and easily applicable manner for research purposes. Methods The SCHEIE grading system is composed of a qualitative and quantitative score. The qualitative score consists of designation in one or more of the following categories: normal, central scotoma, paracentral scotoma, paracentral crescent, temporal quadrant, nasal quadrant, peripheral arcuate defect, expansive arcuate, or altitudinal defect. The quantitative component incorporates the Humphrey visual field index (VFI), location of visual defects for superior and inferior hemifields, and blind spot involvement. Accuracy and speed at grading using the qualitative and quantitative components was calculated for non-physician graders. Results Graders had a median accuracy of 96.67% for their qualitative scores and a median accuracy of 98.75% for their quantitative scores. Graders took a mean of 56 seconds per visual field to assign a qualitative score and 20 seconds per visual field to assign a quantitative score. Conclusion The SCHEIE grading system is a reproducible tool that combines qualitative and quantitative measurements to grade glaucomatous visual field defects. The system aims to standardize clinical staging and to make specific visual field defects more easily identifiable. Specific patterns of visual field loss may also be associated with genetic variants in future genetic analysis. PMID:28932621
Automated grading system for evaluation of ocular redness associated with dry eye
Rodriguez, John D; Johnston, Patrick R; Ousler, George W; Smith, Lisa M; Abelson, Mark B
2013-01-01
Background We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye. Aim To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used. Methods Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0–4 (in 0.5 increments) dry eye redness (Ora Calibra™ Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as “horizontality”). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R – 0.83G – 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset. Results The agreement (both Pearson’s and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a given image has 100% repeatability and zero variability from session to session. Conclusion This objective means of grading ocular redness in a unified fashion has potential significance as a new clinical endpoint. In comparisons between computer and investigator, computer grading proved to be more reliable than another investigator using the OCDER scale. The best fitting model based on the present sample, and usable for future studies, was C4=−12.24+2.12C2HOR+0.88C2RED:C4 is the predicted investigator grade, and C2HOR and C2RED are logarithmic transformations of the computer calculated parameters COM-Hor and COM-Red. Considering the superior repeatability, computer automated grading might be preferable to investigator grading in multicentered dry eye studies in which the subtle differences in redness incurred by treatment have been historically difficult to define. PMID:23814457
King, Wade; Ahmed, Shihab U; Baisden, Jamie; Patel, Nileshkumar; Kennedy, David J; Duszynski, Belinda; MacVicar, John
2015-02-01
To assess the evidence on the validity of sacral lateral branch blocks and the effectiveness of sacral lateral branch thermal radiofrequency neurotomy in managing sacroiliac complex pain. Systematic review with comprehensive analysis of all published data. Six reviewers searched the literature on sacral lateral branch interventions. Each assessed the methodologies of studies found and the quality of the evidence presented. The outcomes assessed were diagnostic validity and effectiveness of treatment for sacroiliac complex pain. The evidence found was appraised in accordance with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) system of evaluating scientific evidence. The searches yielded two primary publications on sacral lateral branch blocks and 15 studies of the effectiveness of sacral lateral branch thermal radiofrequency neurotomy. One study showed multisite, multidepth sacral lateral branch blocks can anesthetize the posterior sacroiliac ligaments. Therapeutic studies show sacral lateral branch thermal radiofrequency neurotomy can relieve sacroiliac complex pain to some extent. The evidence of the validity of these blocks and the effectiveness of this treatment were rated as moderate in accordance with the GRADE system. The literature on sacral lateral branch interventions is sparse. One study demonstrates the face validity of multisite, multidepth sacral lateral branch blocks for diagnosis of posterior sacroiliac complex pain. Some evidence of moderate quality exists on therapeutic procedures, but it is insufficient to determine the indications and effectiveness of sacral lateral branch thermal radiofrequency neurotomy, and more research is required. Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Kaufman, Maurice
The Distar I Reading, Language and Arithmetic programs were used with two first grade classes. The Distar II programs were used with two second grade classes. One first grade Distar class appeared to make some progress in oral language. Comparison of the first grade Distar classes with a first grade control class that used a Scott-Foresman basal…
Development of Grading Systems for Short-Length Lumber
Eugene M. Wengert; Robert W. Rice; James G. Schroeder
1987-01-01
The abundance of low grade hardwood timber and a shortage of high grade timber of many species has led to the examination of alternative processing methods for converting logs to lumber. However, present grading rules for short length lumber are not good predictors of the lumber's true value. A new method of grading short length lumber is proposed, with furniture...
ERIC Educational Resources Information Center
Maxwell, James
Mattatuck Community College implemented non-punitive grading practices into its grading system in the Fall 1973 semester. These practices centered about the elimination of plus and minus grades, elimination of the grade of F, and liberalizing the course withdrawal policy to allow for withdrawal without penalty throughout the semester. A comparison…
ERIC Educational Resources Information Center
Allison, Tracy Michelle Hunter
2012-01-01
The researcher employed two designs to address the research question for this particular study. This quasi-experimental non-equivalent control group study compared the math achievement of 92 eighth grade students who received Classroom Performance System (CPS)-based instruction using Peer Instruction (PI) to 76 eighth grade students who received…
TRSys: A hardwood lumber grading training and remanufacturing system
P. Klinkhachorn; R. Kothari; R. Annavajjhala; Charles W. McMillin
1994-01-01
The Training and Remanufacturing System (TRSys) is a new training tool for teaching both hardwood lumber grading and remanufacturing of lower grade boards into smaller boards of higher total value. TRSys is based on the HaLT2, ReGS, and enhanced HaRem computer programs. The most important feature of this new program is its ablilty to evaluate remanufacturing beyond...
TRSys: a hardwood lumber grading training and remanufacturing system
P. Klinkhachorn; R. Kotharl; R. annavajjhala; Charles W. McMilling
1994-01-01
The training and remanufacturing system( TRsys) is a new training tool for teaching both hardwood lumber and grading and remanufacturing of lower grade boards into smaller boards of higher total value. TRSys is based on HaLT2. REGS, and enhanced HARem computer programs. The mosti mportant feature of this new program is its ability to evaluate remanufacturing beyond...
ERIC Educational Resources Information Center
Tsai, Min-Hsiu
2017-01-01
Who is the most preferred and deemed the most helpful reviewer in improving student writing? This study exercised a blended teaching method which consists of three currently prevailing reviewers: the automated grading system (AGS, a web-based method), the peer review (a process-oriented approach), and the teacher grading technique (the…
ERIC Educational Resources Information Center
Wollersheim Shervey, Sarah; Sandilos, Lia E.; DiPerna, James C.; Lei, Pui-Wa
2017-01-01
The purpose of this study was to examine the social validity of the Social Skills Improvement System--Classwide Intervention Program (SSIS-CIP) for teachers in the primary grades. Participants included 45 first and second grade teachers who completed a 16-item social validity questionnaire during each year of the SSIS-CIP efficacy trial. Findings…
ERIC Educational Resources Information Center
Wollersheim Shervey, Sarah; Sandilos, Lia E.; DiPerna, James C.; Lei, Pui-Wa
2017-01-01
The purpose of this study was to examine the social validity of the Social Skills Improvement System-Classwide Intervention Program (SSIS-CIP) for teachers in the primary grades. Participants included 45 first and second grade teachers who completed a 16-item social validity questionnaire during each year of the SSIS-CIP efficacy trial. Findings…
Automated grading, upgrading, and cuttings prediction of surfaced dry hardwood lumber
Sang-Mook Lee; Phil Araman; A.Lynn Abbott; Matthew F. Winn
2010-01-01
This paper concerns the scanning, sawing, and grading of kiln-dried hardwood lumber. A prototype system is described that uses laser sources and a video camera to scan boards. The system automatically detects defects and wane, searches for optimal sawing solutions, and then estimates the grades of the boards that would result. The goal is to derive maximum commercial...
Hardwood lumber scanning tests to determine NHLA lumber grades
Philip A. Araman; Ssang-Mook Lee; A. Lynn Abbott; Matthew F. Winn
2011-01-01
This paper concerns the scanning, and grading of kiln-dried hardwood lumber. A prototype system is described that uses laser sources and a video camera to scan boards. The system automatically detects defects and wane, grades the boards, and then searches for higher value boards within the original board. The goal is to derive maximum commercial value based on current...
USDA-ARS?s Scientific Manuscript database
The objective of this research was to develop an in-field apple presorting and grading system to separate undersized and defective fruit from fresh market-grade apples. To achieve this goal, a cost-effective machine vision inspection prototype was built, which consisted of a low-cost color camera, L...
Use of an audience response system (ARS) in a dual-campus classroom environment.
Medina, Melissa S; Medina, Patrick J; Wanzer, Donald S; Wilson, Jane E; Er, Nelson; Britton, Mark L
2008-04-15
To implement an audience response system in a dual-campus classroom that aggregated data during graded (attendance and quizzes) and non-graded classroom activities (formative quizzes, case discussions, examination reviews, and team activities) and explore its strengths, weaknesses, and impact on active learning. After extensive research, an appropriate audience response system was selected and implemented in a dual-classroom setting for a third-year required PharmD course. Students were assigned a clicker and training and policies regarding clicker use were reviewed. Activities involving clicker use were carefully planned to simultaneously engage students in both classrooms in real time. Focus groups were conducted with students to gather outcomes data. Students and faculty members felt that the immediate feedback the automated response system (ARS) provided was most beneficial during non-graded activities. Student anxiety increased with use of ARS during graded activities due to fears regarding technology failure, user error, and academic integrity. ARS is a viable tool for increasing active learning in a doctor of pharmacy (PharmD) program, especially when used for non-graded class activities. Faculty members should proceed cautiously with using ARS for graded classroom activities and develop detailed and documented policies for ARS use.
Elimination of the cryptic plasmid in Leuconostoc citreum by CRISPR/Cas9 system.
Jang, Ye-Ji; Seo, Seung-Oh; Kim, Seul-Ah; Li, Ling; Kim, Tae-Jip; Kim, Sun Chang; Jin, Yong-Su; Han, Nam Soo
2017-06-10
Leuconostoc spp. are important lactic acid bacteria for the fermentation of foods. In particular, L. citreum strains isolated from various foods have been used as host strains for genetic and metabolic engineering studies. In order to develop a food-grade genetic engineering system, L. citreum CB2567 was isolated from Kimchi. However, the isolated bacterium contained a cryptic plasmid which was difficult to eliminate. As the existence of the plasmid might hinder strain engineering, we eliminated the plasmid using an RNA-guided DNA endonuclease CRISPR/Cas9 system. We demonstrated that a plasmid-free L. citreum CB2567 host strain could be efficiently constructed through a two-step procedure: 1) transformation of the "killer" plasmid expressing Cas9 endonuclease and a guide RNA (gRNA) targeting for a specific sequence in the cryptic plasmid, and 2) serial subculture without antibiotics for curing the killer plasmid. When the crude extract of L. citreum expressing Cas9 and the guide RNA was incubated with a PCR fragment containing the specific sequence recognized by the guide RNA, the PCR fragment was cleaved. Also, the cryptic plasmid pCB42 was successfully eliminated from the host strain after transforming the plasmid harboring Cas9 and the guide RNA. The Cas9 and gRNA expression plasmid used in this study can be applied for genome engineering purposes by additionally introducing an editing DNA template to repair the double strand DNA breakage caused by Cas9 in the genome of L. citreum. This study demonstrates the feasibility of developing CRISPR/Cas9-based genetic engineering tools to develop a safe host strain and construct food-grade lactic acid bacteria without residual antibiotic markers. Copyright © 2017 Elsevier B.V. All rights reserved.
Caselli, Derek; Liu, Zhicheng; Shelhammer, David; Ning, Cun-Zheng
2014-10-08
Nanomaterials such as semiconductor nanowires have unique features that could enable novel optoelectronic applications such as novel solar cells. This paper aims to demonstrate one such recently proposed concept: Monolithically Integrated Laterally Arrayed Multiple Band gap (MILAMB) solar cells for spectrum-splitting photovoltaic systems. Two cells with different band gaps were fabricated simultaneously in the same process on a single substrate using spatially composition-graded CdSSe alloy nanowires grown by the Dual-Gradient Method in a chemical vapor deposition system. CdSSe nanowire ensemble devices tested under 1 sun AM1.5G illumination achieved open-circuit voltages up to 307 and 173 mV and short-circuit current densities as high as 0.091 and 0.974 mA/cm(2) for the CdS- and CdSe-rich cells, respectively. The open-circuit voltages were roughly three times those of similar CdSSe film cells fabricated for comparison due to the superior optical quality of the nanowires. I-V measurements were also performed using optical filters to simulate spectrum-splitting. The open-circuit voltages and fill factors of the CdS-rich subcells were uniformly larger than the corresponding CdSe-rich cells for similar photon flux, as expected. This suggests that if all wires can be contacted, the wide-gap cell is expected to have greater output power than the narrow-gap cell, which is the key to achieving high efficiencies with spectrum-splitting. This paper thus provides the first proof-of-concept demonstration of simultaneous fabrication of MILAMB solar cells. This approach to solar cell fabrication using single-crystal nanowires for spectrum-splitting photovoltaics could provide a future low-cost high-efficiency alternative to the conventional high-cost high-efficiency tandem cells.
Spatial Modeling of Geometallurgical Properties: Techniques and a Case Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deutsch, Jared L., E-mail: jdeutsch@ualberta.ca; Palmer, Kevin; Deutsch, Clayton V.
High-resolution spatial numerical models of metallurgical properties constrained by geological controls and more extensively by measured grade and geomechanical properties constitute an important part of geometallurgy. Geostatistical and other numerical techniques are adapted and developed to construct these high-resolution models accounting for all available data. Important issues that must be addressed include unequal sampling of the metallurgical properties versus grade assays, measurements at different scale, and complex nonlinear averaging of many metallurgical parameters. This paper establishes techniques to address each of these issues with the required implementation details and also demonstrates geometallurgical mineral deposit characterization for a copper–molybdenum deposit inmore » South America. High-resolution models of grades and comminution indices are constructed, checked, and are rigorously validated. The workflow demonstrated in this case study is applicable to many other deposit types.« less
Aydin, Omer; Buyukkaya, Ramazan; Hakyemez, Bahattin
2017-01-01
Susceptibility weighted imaging (SWI) is a velocity compensated, high-resolution three-dimensional (3D) spoiled gradient-echo sequence that uses magnitude and filtered-phase data. SWI seems to be a valuable tool for non-invasive evaluation of central nervous system gliomas. Relative cerebral blood volume (rCBV) ratio is one of the best noninvasive methods for glioma grading. Degree of intratumoral susceptibility signal (ITSS) on SWI correlates with rCBV ratio and histopathological grade. This study investigated the effectiveness of ITSS grading and rCBV ratio in preoperative assessment. Thirty-one patients (17 males and 14 females) with histopathogical diagnosis of glial tumor undergoing routine cranial MRI, SWI, and perfusion MRI examinations between October 2011 and July 2013 were retrospectively enrolled. All examinations were performed using 3T apparatus with 32-channel head coil. We used ITSS number for SWI grading. Correlations between SWI grade, rCBV ratio, and pathological grading were evaluated. ROC analysis was performed to determine the optimal rCBV ratio to distinguish between high-grade and low-grade glial tumors. There was a strong positive correlation between both pathological and SWI grading. We determined the optimal rCBV ratio to discriminate between high-grade and low-grade tumors to be 2.21. In conclusion, perfusion MRI and SWI using 3T MR and 32-channel head coil may provide useful information for preoperative glial tumor grading. SWI can be used as an accessory to perfusion MR technique in preoperative tumor grading.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-03
... Systems and Wayside Signal Systems AGENCY: Federal Railroad Administration (FRA), Department of... traveling public and railroad employees when highway- rail grade crossing warning systems and wayside signal systems are temporarily removed from service for purposes of testing, inspection, maintenance, or repair...
Aluminum anode for aluminum-air battery - Part I: Influence of aluminum purity
NASA Astrophysics Data System (ADS)
Cho, Young-Joo; Park, In-Jun; Lee, Hyeok-Jae; Kim, Jung-Gu
2015-03-01
2N5 commercial grade aluminum (99.5% purity) leads to the lower aluminum-air battery performances than 4N high pure grade aluminum (99.99% purity) due to impurities itself and formed impurity complex layer which contained Fe, Si, Cu and others. The impurity complex layer of 2N5 grade Al declines the battery voltage on standby status. It also depletes discharge current and battery efficiency at 1.0 V which is general operating voltage of aluminum-air battery. However, the impurity complex layer of 2N5 grade Al is dissolved with decreasing discharge voltage to 0.8 V. This phenomenon leads to improvement of discharge current density and battery efficiency by reducing self-corrosion reaction. This study demonstrates the possibility of use of 2N5 grade Al which is cheaper than 4N grade Al as the anode for aluminum-air battery.
The Minnesota Grading System of eye bank eyes for age-related macular degeneration.
Olsen, Timothy W; Feng, Xiao
2004-12-01
The Minnesota Grading System (MGS) is a method to evaluate human eye bank eyes and determine the level of age-related macular degeneration (AMD), by using criteria and definitions from the Age-Related Eye Disease Study (AREDS). Donor eyes (108 pairs) from the Minnesota Lions Eye Bank were cut circumferentially at the pars plana to remove the anterior segment. A 1000 +/- 2.5-microm ruby sphere was placed on the optic nerve as a size reference. A digital, high-resolution, color macular photograph was taken through a dissecting microscope. The neurosensory retina was removed from one globe of the pair. The underlying retinal pigment epithelium was rephotographed, localizing the fovea with a proportional triangle. A grid was superimposed in the macular photographs and images were graded according to AREDS criteria. Twenty pairs were dissected bilaterally and graded for symmetry. Eighty-eight globes were graded into one of four MGS categories. Nineteen (95%) of 20 globes had symmetric grades. The MGS provides a methodology to grade donor tissue from eye bank eyes to correspond to the AREDS classification system. Donor tissue may be used for subsequent molecular analysis, including genomics and proteomics.
Toffola, Elena Dalla; Pavese, Chiara; Cecini, Miriam; Petrucci, Lucia; Ricotti, Susanna; Bejor, Maurizio; Salimbeni, Grazia; Biglioli, Federico; Klersy, Catherine
2014-01-01
Summary Our study evaluates the grade and timing of recovery in 30 patients with complete facial paralysis (House-Brackmann grade VI) treated with hypoglossal-facial nerve (XII-VII) anastomosis and a long-term rehabilitation program, consisting of exercises in facial muscle activation mediated by tongue movement and synkinesis control with mirror feedback. Reinnervation after XII-VII anastomosis occurred in 29 patients, on average 5.4 months after surgery. Three years after the anastomosis, 23.3% of patients had grade II, 53.3% grade III, 20% grade IV and 3.3% grade VI ratings on the House-Brackmann scale. Time to reinnervation was associated with the final House-Brackmann grade. Our study demonstrates that patients undergoing XII-VII anastomosis and a long-term rehabilitation program display a significant recovery of facial symmetry and movement. The recovery continues for at least three years after the anastomosis, meaning that prolonged follow-up of these patients is advisable. PMID:25473738
MAESTRO: Mathematics and Earth Science Teachers' Resource Organization
NASA Astrophysics Data System (ADS)
Courtier, A. M.; Pyle, E. J.; Fichter, L.; Lucas, S.; Jackson, A.
2013-12-01
The Mathematics and Earth Science Teachers' Resource Organization (MAESTRO) partnership between James Madison University and Harrisonburg City and Page County Public Schools, funded through NSF-GEO. The partnership aims to transform mathematics and Earth science instruction in middle and high schools by developing an integrated mathematics and Earth systems science approach to instruction. This curricular integration is intended to enhance the mathematical skills and confidence of students through concrete, Earth systems-based examples, while increasing the relevance and rigor of Earth science instruction via quantification and mathematical modeling of Earth system phenomena. MAESTRO draws heavily from the Earth Science Literacy Initiative (2009) and is informed by criterion-level standardized test performance data in both mathematics and Earth science. The project has involved two summer professional development workshops, academic year Lesson Study (structured teacher observation and reflection), and will incorporate site-based case studies with direct student involvement. Participating teachers include Grade 6 Science and Mathematics teachers, and Grade 9 Earth Science and Algebra teachers. It is anticipated that the proposed integration across grade bands will first strengthen students' interests in mathematics and science (a problem in middle school) and subsequently reinforce the relevance of mathematics and other sciences (a problem in high school), both in support of Earth systems literacy. MAESTRO's approach to the integration of math and science focuses on using box models to emphasize the interconnections among the geo-, atmo-, bio-, and hydrospheres, and demonstrates the positive and negative feedback processes that connect their mutual evolution. Within this framework we explore specific relationships that can be described both qualitatively and mathematically, using mathematical operations appropriate for each grade level. Site-based case studies, developed in collaboration between teachers and JMU faculty members, provide a tangible, relevant setting in which students can apply and understand mathematical applications and scientific processes related to evolving Earth systems. Initial results from student questionnaires and teacher focus groups suggest that the anticipated impacts of MAESTRO on students are being realized, including increased valuing of mathematics and Earth science in society and transfer between mathematics and science courses. As a high percentage of students in the MAESTRO schools are of low socio-economic status, they also face the prospect of becoming first-generation college students, hopefully considering STEM academic pathways. MAESTRO will drive the development of challenging and engaging instruction designed to draw a larger pool of students into STEM career pathways.
Prospective evaluation of the Sunshine Appendicitis Grading System score.
Reid, Fiona; Choi, Julian; Williams, Marli; Chan, Steven
2017-05-01
Although there is a wealth of information predicting risk of post-operative intra-abdominal collection and guiding antibiotic therapy following appendicectomy, confusion remains because of lack of consensus on the clinical severity and definition of 'complicated' appendicitis. This study aimed to develop a standardized intra-operative grading system: Sunshine Appendicitis Grading System (SAGS) for acute appendicitis that correlates independently with the risk of intra-abdominal collections. Two-hundred and forty-six patients undergoing emergency laparoscopy for suspected appendicitis were prospectively scored according to the severity of appendicitis and followed up for complications including intra-abdominal collection. After termination of the study, the SAGS score was repeated by an independent surgeon based on operation notes and intra-operative photography to determine inter-rater agreement. The primary outcome measure was incidence of intra-abdominal collection, secondary outcome measures were all complications and length of stay. SAGS score demonstrated good inter-rater agreement (kappa K w 0.869; 95% CI 0.796-0.941; P < 0.001). A risk ratio of 2.594 (95% CI 0.655-4.065; P < 0.001) for intra-abdominal collection was found using SAGS score as a predictor. The discriminative ability of SAGS score was supported by an area under the curve value of 0.850 (95% CI 0.799-0.892; P < 0.001). SAGS score can be used to simply and accurately classify the severity of appendicitis and to independently predict the risk of intra-abdominal collection. It can therefore be used to stratify risk, guide antibiotic therapy, follow-up and standardize the definitions of appendicitis severity for future research. © 2015 Royal Australasian College of Surgeons.
Shin, Dongsuk; Pierce, Mark C; Gillenwater, Ann M; Williams, Michelle D; Richards-Kortum, Rebecca R
2010-06-23
Early detection is an essential component of cancer management. Unfortunately, visual examination can often be unreliable, and many settings lack the financial capital and infrastructure to operate PET, CT, and MRI systems. Moreover, the infrastructure and expense associated with surgical biopsy and microscopy are a challenge to establishing cancer screening/early detection programs in low-resource settings. Improvements in performance and declining costs have led to the availability of optoelectronic components, which can be used to develop low-cost diagnostic imaging devices for use at the point-of-care. Here, we demonstrate a fiber-optic fluorescence microscope using a consumer-grade camera for in vivo cellular imaging. The fiber-optic fluorescence microscope includes an LED light, an objective lens, a fiber-optic bundle, and a consumer-grade digital camera. The system was used to image an oral cancer cell line labeled with 0.01% proflavine. A human tissue specimen was imaged following surgical resection, enabling dysplastic and cancerous regions to be evaluated. The oral mucosa of a healthy human subject was imaged in vivo, following topical application of 0.01% proflavine. The fiber-optic microscope resolved individual nuclei in all specimens and tissues imaged. This capability allowed qualitative and quantitative differences between normal and precancerous or cancerous tissues to be identified. The optical efficiency of the system permitted imaging of the human oral mucosa in real time. Our results indicate this device as a useful tool to assist in the identification of early neoplastic changes in epithelial tissues. This portable, inexpensive unit may be particularly appropriate for use at the point-of-care in low-resource settings.
Critchley-Thorne, Rebecca J; Davison, Jon M; Prichard, Jeffrey W; Reese, Lia M; Zhang, Yi; Repa, Kathleen; Li, Jinhong; Diehl, David L; Jhala, Nirag C; Ginsberg, Gregory G; DeMarshall, Maureen; Foxwell, Tyler; Jobe, Blair A; Zaidi, Ali H; Duits, Lucas C; Bergman, Jacques J G H M; Rustgi, Anil; Falk, Gary W
2017-02-01
There is a need for improved tools to detect high-grade dysplasia (HGD) and esophageal adenocarcinoma (EAC) in patients with Barrett's esophagus. In previous work, we demonstrated that a 3-tier classifier predicted risk of incident progression in Barrett's esophagus. Our aim was to determine whether this risk classifier could detect a field effect in nondysplastic (ND), indefinite for dysplasia (IND), or low-grade dysplasia (LGD) biopsies from Barrett's esophagus patients with prevalent HGD/EAC. We performed a multi-institutional case-control study to evaluate a previously developed risk classifier that is based upon quantitative image features derived from 9 biomarkers and morphology, and predicts risk for HGD/EAC in Barrett's esophagus patients. The risk classifier was evaluated in ND, IND, and LGD biopsies from Barrett's esophagus patients diagnosed with HGD/EAC on repeat endoscopy (prevalent cases, n = 30, median time to HGD/EAC diagnosis 140.5 days) and nonprogressors (controls, n = 145, median HGD/EAC-free surveillance time 2,015 days). The risk classifier stratified prevalent cases and non-progressor patients into low-, intermediate-, and high-risk classes [OR, 46.0; 95% confidence interval, 14.86-169 (high-risk vs. low-risk); P < 0.0001]. The classifier also provided independent prognostic information that outperformed the subspecialist and generalist diagnosis. A tissue systems pathology test better predicts prevalent HGD/EAC in Barrett's esophagus patients than pathologic variables. The results indicate that molecular and cellular changes associated with malignant transformation in Barrett's esophagus may be detectable as a field effect using the test. A tissue systems pathology test may provide an objective method to facilitate earlier identification of Barrett's esophagus patients requiring therapeutic intervention. Cancer Epidemiol Biomarkers Prev; 26(2); 240-8. ©2016 AACR. ©2016 American Association for Cancer Research.
Sada, Ken-Ei; Harigai, Masayoshi; Amano, Koichi; Atsumi, Tatsuya; Fujimoto, Shouichi; Yuzawa, Yukio; Takasaki, Yoshinari; Banno, Shogo; Sugihara, Takahiko; Kobayashi, Masaki; Usui, Joichi; Yamagata, Kunihiro; Homma, Sakae; Dobashi, Hiroaki; Tsuboi, Naotake; Ishizu, Akihiro; Sugiyama, Hitoshi; Okada, Yasunori; Arimura, Yoshihiro; Matsuo, Seiichi; Makino, Hirofumi
2016-09-01
To compare disease severity classification systems for six-month outcome prediction in patients with antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV). Patients with newly diagnosed AAV from 53 tertiary institutions were enrolled. Six-month remission, overall survival, and end-stage renal disease (ESRD)-free survival were evaluated. According to the European Vasculitis Study Group (EUVAS)-defined disease severity, the 321 enrolled patients were classified as follows: 14, localized; 71, early systemic; 170, generalized; and 66, severe disease. According to the rapidly progressive glomerulonephritis (RPGN) clinical grading system, the patients were divided as follows: 60, grade I; 178, grade II; 66, grade III; and 12, grade IV. According to the Five-Factor Score (FFS) 2009, 103, 109, and 109 patients had ≤1, 2, and ≥3 points, respectively. No significant difference in remission rates was found in any severity classification. The overall and ESRD-free survival rates significantly differed between grades I/II, III, and IV, regardless of renal involvement. Severe disease was a good predictor of six-month overall and ESRD-free survival. The FFS 2009 was useful to predict six-month ESRD-free survival but not overall survival. The RPGN grading system was more useful to predict six-month overall and ESRD-free survival than the EUVAS-defined severity or FFS 2009.
25 CFR 36.30 - Standard X-Grading requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true Standard X-Grading requirements. 36.30 Section 36.30 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS FOR THE... Evaluation § 36.30 Standard X—Grading requirements. (a) Each school shall implement a uniform grading system...
25 CFR 36.30 - Standard X-Grading requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false Standard X-Grading requirements. 36.30 Section 36.30 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS FOR THE... Evaluation § 36.30 Standard X—Grading requirements. (a) Each school shall implement a uniform grading system...
25 CFR 36.30 - Standard X-Grading requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false Standard X-Grading requirements. 36.30 Section 36.30 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS FOR THE... Evaluation § 36.30 Standard X—Grading requirements. (a) Each school shall implement a uniform grading system...
25 CFR 36.30 - Standard X-Grading requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false Standard X-Grading requirements. 36.30 Section 36.30 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS FOR THE... Evaluation § 36.30 Standard X—Grading requirements. (a) Each school shall implement a uniform grading system...
25 CFR 36.30 - Standard X-Grading requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false Standard X-Grading requirements. 36.30 Section 36.30 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS FOR THE... Evaluation § 36.30 Standard X—Grading requirements. (a) Each school shall implement a uniform grading system...
Research on Same-Gender Grouping in Eighth Grade Science Classrooms
ERIC Educational Resources Information Center
Friend, Jennifer
2006-01-01
This study examined two hypotheses related to same-gender grouping of eighth grade science classes in a public middle school setting. The hypotheses were (a) male and female students enrolled in same-gender science classes demonstrate more positive science academic achievement than their peers enrolled in mixed-gender classes, and (b) same-gender…
ERIC Educational Resources Information Center
Yan, Ni; Dix, Theodore
2016-01-01
Using data from the National Institute of Child Health and Human Development (NICHD) Study of Early Child Care and Youth Development (N = 1,364), the present study supports an agentic perspective; it demonstrates that mothers' depressive symptoms in infancy predict children's poor first-grade cognitive functioning because depressive symptoms…
Using Art Elicitation to Deliver and Evaluate a Grade 4 Climate Change Instructional Module
ERIC Educational Resources Information Center
Baker, Jillian; Loxton, Jason; Sherren, Kate
2013-01-01
We report the results of a climate change module delivered to 48 Grade 3/4 students in Nova Scotia, Canada. We tested for prior knowledge and evaluated interventional effectiveness using art elicitation. Common climate change misconceptions were demonstrated in their preintervention artwork, while postintervention artwork showed improved…
Prevalence and Nature of Late-Emerging Poor Readers
ERIC Educational Resources Information Center
Catts, Hugh W.; Compton, Donald; Tomblin, J. Bruce; Bridges, Mindy Sittner
2012-01-01
Some children demonstrate adequate or better reading achievement in early school grades but fall significantly behind their peers in later grades. These children are often referred to as late-emerging poor readers. In this study, we investigated the prevalence and heterogeneity of these poor readers. We also examined the early language and…
Creating Science Picture Books for an Authentic Audience
ERIC Educational Resources Information Center
DeFauw, Danielle L.; Saad, Klodia
2014-01-01
This article presents an authentic writing opportunity to help ninth-grade students use the writing process in a science classroom to write and illustrate picture books for fourth-grade students to demonstrate and share their understanding of a biology unit on cells. By creating a picture book, students experience the writing process, understand…
scientists know how magnets big and small work and how they apply to our world. Students explore the and Motion Grades 2-8 Speed, motion, momentum, gravity, forces. These realities control our world, but Grades 2-8 Light helps us learn and explore our world! Students explore the phenomenon of light and how
How Fit Are Elementary Children in Grades 2-4?
ERIC Educational Resources Information Center
Lemlech, Johanna K.
As part of a Feelin' Good intervention program to improve the physical fitness of children in grades 2 through 4, 603 students were tested for muscle strength and flexibility. Complete pre- and posttest data were obtained from 388 students. Two muscle strength tests and two flexibility tests demonstrated consistent sex differences in performance.…
How Fifth-Grade Students Use Story Mapping to Aid Their Reading Comprehension
ERIC Educational Resources Information Center
Weih, Timothy G.
2000-01-01
This thesis examined the reading comprehension process of three fifth-grade students who demonstrated the ability to read and write fluently but had difficulties remembering and understanding important information about what they read. The aim of this research was to develop and implement an effective teaching strategy for low-achieving students…
Investigating the utility of a GPA institutional adjustment index.
Didier, Thomas; Kreiter, Clarence D; Buri, Russell; Solow, Catherine
2006-05-01
Grading standards vary widely across undergraduate institutions. If, during the medical school admissions process, GPA is considered without reference to the institution attended, it will disadvantage applicants from undergraduate institutions employing rigorous grading standards. A regression-based GPA institutional equating method using historical MCAT and GPA information is described. Classes selected from eight applicant pools demonstrate the impact of the GPA adjustment. The validity of the adjustment is examined by comparing adjusted and unadjusted GPAs' correlation with USMLE and medical college grades. The adjusted GPA demonstrated significantly improved congruence with MCAT estimates of applicant preparedness. The adjustment changed selection decisions for 21% of those admitted. The adjusted GPA enhanced prediction of USMLE and medical school grades only for students from institutions which required large adjustments. Unlike other indices, the adjustment described uses the same metric as GPA and is based only on an institution's history of preparing medical school applicants. The institutional adjustment is consequential in selection, significantly enhances congruence with a standardized measure of academic preparedness and may enhance the validity of the GPA.
Potential of thermally conductive polymers for the cooling of mechatronic parts
NASA Astrophysics Data System (ADS)
Heinle, C.; Drummer, D.
Adding thermally conductive fillers to polymers the thermal conductivity can be raised significantly. Thermal conductive polymers (TC-plastics) open up a vast range of options to set up novel concepts of polymer technological system solutions in the area of mechatronics. Heating experiment of cooling ribs show the potential in thermal management of mechatronic parts with TC-polymers in comparison with widely used reference materials copper and aluminum. The results demonstrate that especially for certain thermal boundary conditions comparable performance between these two material grades can be measured.
Tajima, Shogo; Aki, Michihiko; Yajima, Kiyoshige; Takahashi, Tsuyoshi; Neyatani, Hiroshi; Koda, Kenji
2015-07-01
Primary salivary gland-type tumors of the lung are rare; among them, epithelial-myoepithelial carcinomas (EMC) represent a minor histological subtype. The present case documents an EMC that occluded the B8 segment of the left lung in a 72-year-old woman. Macroscopically, the tumor was well-demarcated; however, microscopic examination demonstrated that it had infiltrated the lung parenchyma. The majority of the tumor mass was composed of a myoepithelial overgrowth in conjunction with conventional bilayered ductal structures comprising epithelial and myoepithelial cells. At the advancing edge of the tumor, the myoepithelial overgrowth was observed to be gradually transitioning to a higher-grade component, which demonstrated venous invasion. The Ki-67 labeling index was reduced compared with high-grade transformation (HGT) of salivary gland EMC; p53 was sparsely observed on immunostaining. However, cyclin D1, which is reported to be overexpressed in certain subtypes of salivary gland carcinomas with HGT, was overexpressed in the higher-grade component of the tumor, indicating a potential HGT initiation. The surgical margin was tumor free, and no recurrence has been observed for 4 months. A thorough follow-up is required considering the HGT-like changes and venous invasion of the tumor. Additional studies are required to elucidate the characteristics of pulmonary EMC, with an emphasis on detecting HGT or HGT-like changes.
ERIC Educational Resources Information Center
Hurdle, Zachariah B.
2017-01-01
The purpose of the dissertation is to investigate three particular aspects that may affect the transition between a third grade Montessori system and a fourth grade non-Montessori system, specifically within the context of teaching and learning mathematics. These aspects are 1) the change in pacing and structure of the classroom, 2) the removal of…
Improved grading system for structural logs for log homes
D.W. Green; T.M. Gorman; J.W. Evans; J.F. Murphy
2004-01-01
Current grading standards for logs used in log home construction use visual criteria to sort logs into either âwall logsâ or structural logs (round and sawn round timbers). The conservative nature of this grading system, and the grouping of stronger and weaker species for marketing purposes, probably results in the specification of logs with larger diameter than would...
ERIC Educational Resources Information Center
Massachusetts Department of Elementary and Secondary Education, 2013
2013-01-01
The Massachusetts Department of Elementary and Secondary Education (Department) created the grades 1-12 Early Warning Indicator System (EWIS) in response to district interest in the Early Warning Indicator Index (EWII) that the Department previously created for rising grade 9 students. Districts shared that the EWII data were helpful, but also…
ERIC Educational Resources Information Center
Massachusetts Department of Elementary and Secondary Education, 2013
2013-01-01
The Massachusetts Department of Elementary and Secondary Education (Department) created the grades 1-12 Early Warning Indicator System (EWIS) in response to district interest in the Early Warning Indicator Index (EWII) that the Department previously created for rising grade 9 students. Districts shared that the EWII data were helpful, but also…
Development of silicon carbide semiconductor devices for high temperature applications
NASA Technical Reports Server (NTRS)
Matus, Lawrence G.; Powell, J. Anthony; Petit, Jeremy B.
1991-01-01
The semiconducting properties of electronic grade silicon carbide crystals, such as wide energy bandgap, make it particularly attractive for high temperature applications. Applications for high temperature electronic devices include instrumentation for engines under development, engine control and condition monitoring systems, and power conditioning and control systems for space platforms and satellites. Discrete prototype SiC devices were fabricated and tested at elevated temperatures. Grown p-n junction diodes demonstrated very good rectification characteristics at 870 K. A depletion-mode metal-oxide-semiconductor field-effect transistor was also successfully fabricated and tested at 770 K. While optimization of SiC fabrication processes remain, it is believed that SiC is an enabling high temperature electronic technology.
Simultaneous miocene extension and shortening in the himalayan orogen.
Hodges, K V; Parrish, R R; Housh, T B; Lux, D R; Burchfiel, B C; Royden, L H; Chen, Z
1992-11-27
The South Tibetan detachment system separates the high-grade metamorphic core of the Himalayan orogen from its weakly metamorphosed suprastructure. It is thought to have developed in response to differences in gravitational potential energy produced by crustal thickening across the mountain front. Geochronologic data from the Rongbuk Valley, north of Qomolangma (Mount Everest) in southern Tibet, demonstrate that at least one segment of the detachment system was active between 19 and 22 million years ago, an interval characterized by large-scale crustal thickening at lower structural levels. These data suggest that decoupling between an extending upper crust and a converging lower crust was an important aspect of Himalayan tectonics in Miocene time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liss, W.; Dybel, M.; West, R.
This report covers the first year's work performed by the Gas Technology Institute and Encorp Inc. under subcontract to the National Renewable Energy Laboratory. The objective of this three-year contract is to develop innovative grid interconnection and control systems. This supports the advancement of distributed generation in the marketplace by making installations more cost-effective and compatible across the electric power and energy management systems. Specifically, the goals are: (1) To develop and demonstrate cost-effective distributed power grid interconnection products and software and communication solutions applicable to improving the economics of a broad range of distributed power systems, including existing, emerging,more » and other power generation technologies. (2) To enhance the features and capabilities of distributed power products to integrate, interact, and provide operational benefits to the electric power and advanced energy management systems. This includes features and capabilities for participating in resource planning, the provision of ancillary services, and energy management. Specific topics of this report include the development of an advanced controller, a power sensing board, expanded communication capabilities, a revenue-grade meter interface, and a case study of an interconnection distributed power system application that is a model for demonstrating the functionalities of the design of the advanced controller.« less
Langberg, Joshua M.; Dvorsky, Melissa R.; Molitor, Stephen J.; Bourchtein, Elizaveta; Eddy, Laura D.; Smith, Zoe; Schultz, Brandon K.; Evans, Steven W.
2016-01-01
The primary goal of this study was to longitudinally evaluate the homework assignment completion patterns of middle school age adolescents with ADHD, their associations with academic performance, and malleable predictors of homework assignment completion. Analyses were conducted on a sample of 104 middle school students comprehensively diagnosed with ADHD and followed for 18 months. Multiple teachers for each student provided information about the percentage of homework assignments turned in at five separate timepoints and school grades were collected quarterly. Results showed that agreement between teachers with respect to students’ assignment completion was high, with an intraclass correlation of .879 at baseline. Students with ADHD were turning in an average of 12% fewer assignments each academic quarter in comparison to teacher-reported classroom averages. Regression analyses revealed a robust association between the percentage of assignments turned in at baseline and school grades 18 months later, even after controlling for baseline grades, achievement (reading and math), intelligence, family income, and race. Cross-lag analyses demonstrated that the association between assignment completion and grades was reciprocal, with assignment completion negatively impacting grades and low grades in turn being associated with decreased future homework completion. Parent ratings of homework materials management abilities at baseline significantly predicted the percentage of assignments turned in as reported by teachers 18 months later. These findings demonstrate that homework assignment completion problems are persistent across time and an important intervention target for adolescents with ADHD. PMID:26931065
The skills and experience of GRADE methodologists can be assessed with a simple tool.
Norris, Susan L; Meerpohl, Joerg J; Akl, Elie A; Schünemann, Holger J; Gartlehner, Gerald; Chen, Yaolong; Whittington, Craig
2016-11-01
To suggest approaches for guideline developers on how to assess a methodologist's expertise with Grading of Recommendations Assessment, Development and Evaluation (GRADE) methods and tasks and to provide a set of minimum skills and experience required to perform specific tasks related to guideline development using GRADE. We used an iterative and consensus-based process involving individuals with in-depth experience with GRADE. We considered four main tasks: (1) development of key questions; (2) assessment of the certainty of effect estimates; (3) development of recommendations; and (4) teaching GRADE. There are three basic approaches to determine a methodologist's skill set. First, self-report of knowledge, skills, and experience with a standardized "GRADE curriculum vitae (CV)" focused on each of the GRADE-related tasks; second, demonstration of skills using worked examples; third, a formal evaluation using a written or oral test. We suggest that the GRADE CV is likely to be useful and feasible to implement. We also suggest minimum training including attendance at one or more full-day workshops and familiarity with the main GRADE publications and the GRADE handbook. The selection of a GRADE methodologist must be a thoughtful, reasoned decision, informed by the criteria suggested in this article and tailored to the specific project. Our suggested approaches need further pilot testing and validation. Copyright © 2016 Elsevier Inc. All rights reserved.
[Evaluation of preliminary grades and credits in nurse training programs].
Darmann-Finck, Ingrid; Duveneck, Nicole
2016-01-01
In the federal state of Bremen preliminary grades were included to the extent of 25 % in written, oral and practical final grades during the time period 2009-2014. The evaluation focuses on the effects of preliminary grades on the scale of final grades and the performance of learners as well as on the assessment of the appropriateness of final grades. A mixed-methods design was employed that consisted of a quasi-experimental study comprising of surveys of students and teachers of comparative and model courses as well as a qualitative study using group discussions. The results confirm that preliminary grades lead to a minimal improvement of the final grades of some exclusively low-achieving students. The assessment of appropriateness hardly changed. From both learners' and teachers' point of view there is still great dissatisfaction concerning the practical final grades. With regard to learning habits an increased willingness to learn new skills on the one hand and a partly increased performance pressure on the other hand were demonstrated. On the basis of these research results, the authors recommend the regular introduction of preliminary marks into the nursing training. Copyright © 2016. Published by Elsevier GmbH.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false General. 532.601 Section 532.601 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PREVAILING RATE SYSTEMS Job Grading System § 532.601 General. The Office of Personnel Management shall establish a job grading system...
[GRADE system: classification of quality of evidence and strength of recommendation].
Aguayo-Albasini, José Luis; Flores-Pastor, Benito; Soria-Aledo, Víctor
2014-02-01
The acquisition and classification of scientific evidence, and subsequent formulation of recommendations constitute the basis for the development of clinical practice guidelines. There are several systems for the classification of evidence and strength of recommendations; the most commonly used nowadays is the Grading of Recommendations, Assessment, Development and Evaluation system (GRADE). The GRADE system initially classifies the evidence into high or low, coming from experimental or observational studies; subsequently and following a series of considerations, the evidence is classified into high, moderate, low or very low. The strength of recommendations is based not only on the quality of the evidence, but also on a series of factors such as the risk/benefit balance, values and preferences of the patients and professionals, and the use of resources or costs. Copyright © 2013 AEC. Published by Elsevier Espana. All rights reserved.
Jois, Bhargavi; Asopa, Ramesh; Basu, Sandip
2014-06-01
The aim of the study was to evaluate somatostatin receptor expression in non-I-concentrating metastatic differentiated thyroid carcinoma by Ga-DOTATATE PET-CT/Tc-HYNIC-TOC scintigraphy and to determine the feasibility of Lu-DOTATATE (therapeutic analog) therapy in cases with positive Ga-DOTATATE PET-CT/Tc-HYNIC-TOC scintigraphy. In this research study, 19 patients diagnosed with differentiated thyroid carcinoma with non-iodine-concentrating metastasis with elevated serum thyroglobulin levels, attending thyroid outpatient department for follow-up, underwent Ga-DOTATATE PET-CT/Tc-HYNIC-TOC scan for the evaluation of positivity of somatostatin receptor (SSTR). Based on the visual grading, SSTR-positive lesions were graded into 4 categories (grades I-IV) in comparison with the hepatic uptake on the scan. Patients with grades III and IV uptake in lesions (equal to or more than hepatic uptake on scan) were scheduled for Lu-DOTATATE administration. Posttherapy Lu-DOTATATE scan was undertaken during discharge from the isolation ward. Of the 19 patients studied, 12 patients (63%) showed SSTR-positive lesion expression demonstrating uptake ranging from grade I-IV, and 7 patients (37%) did not demonstrate any tracer uptake. On a lesion-specific analysis, of the total 57 metastatic lesions, 4 lesions (7%) demonstrated grade I tracer uptake, 18 lesions (31%) grade II (less than liver), 2 lesions (3.5%) grade III (equal to liver uptake), and 1 lesion showed grade IV uptake (more than liver). Interestingly, an elevated serum chromogranin A level was documented in 3 of the patients with grades III and IV tumor uptake. A comparison of Ga-DOTATATE PET-CT and Tc-HYNIC-TOC in 4 patients who underwent both the scans demonstrated no significant differences in the tracer concentration in the metastatic lesions in any of the patients on visual grading. Based on the criterion of high tracer uptake and the patient consent, finally 2 of 3 patients were treated with Lu-DOTATATE. On follow-up after 3 months, a significant fall in serum thyroglobulin level was noted in one of the patients, and the other patient was lost to follow-up. Avid expression of the SSTR on Ga-DOTATATE PET-CT/Tc-HYNIC-TOC scintigraphy in non-I-concentrating metastatic differentiated thyroid cancer is observed in a relatively low fraction of patients that could favor the feasibility of Lu-DOTATATE therapy. Although seen in a small fraction, taking into account that no treatment exists in this group, somatostatin receptor-targeted imaging can be an alternative diagnostic modality in the therapeutic decision making with peptide receptor radionuclide therapy and monitoring. The documentation of elevated serum chromogranin A level in 3 patients with intense tracer uptake could suggest a possible neuroendocrine differentiation in the affected tissues leading to the expression of chromogranin A along with SSTR-avid expression. This observation needs to be explored in future studies. No definite conclusions can be drawn on the therapeutic efficacy of the Lu-DOTATATE therapy in this group at present, and more prospective research is required in this area.
YouTube provides irrelevant information for the diagnosis and treatment of hip arthritis.
Koller, Ulrich; Waldstein, Wenzel; Schatz, Klaus-Dieter; Windhager, Reinhard
2016-10-01
YouTube is increasingly becoming a key source for people to satisfy the need for additional information concerning their medical condition. This study analyses the completeness of accurate information found on YouTube pertaining to hip arthritis. The present study analyzed 133 YouTube videos using the search terms: hip arthritis, hip arthritis symptoms, hip arthritis diagnosis, hip arthritis treatment and hip replacement. Two quality assessment checklists with a scale of 0 to 12 points were developed to evaluate available video content for the diagnosis and the treatment of hip arthritis. Videos were grouped into poor quality (grade 0-3), moderate quality (grade 4-7) and excellent quality (grade 8-12), respectively. Three independent observers assessed all videos using the new grading system and independently scored all videos. Discrepancies regarding the categories were clarified by consensus discussion. For intra-observer reliabilities, grading was performed at two occasions separated by four weeks. Eighty-four percent (n = 112) had a poor diagnostic information quality, 14% (n = 19) a moderate quality and only 2% (n = 2) an excellent quality, respectively. In 86% (n = 114), videos provided poor treatment information quality. Eleven percent (n = 15) of videos had a moderate quality and only 3% (n = 4) an excellent quality, respectively. The present study demonstrates that YouTube is a poor source for accurate information pertaining to the diagnosis and treatment of hip arthritis. These finding are of high relevance for clinicians as videos are going to become the primary source of information for patients. Therefore, high quality educational videos are needed to further guide patients on the way from the diagnosis of hip arthritis to its proper treatment.
Sinikumpu, Suvi-Päivikki; Huilaja, Laura; Auvinen, Juha; Jokelainen, Jari; Puukka, Katri; Ruokonen, Aimo; Timonen, Markku; Tasanen, Kaisa
2018-01-12
Low grade inflammation is associated with many noncommunicable diseases. The association between skin diseases in general and systemic inflammation has not previously been studied at the population level. A whole-body investigation on 1,930 adults belonging to Northern Finland Birth Cohort 1966 was performed and high sensitive C-reactive protein (CRP) level was measured as a marker of low grade inflammation in order to determine the association between low grade inflammation and skin diseases in an unselected adult population. After adjustment for confounding factors the following skin disorders were associated with low grade inflammation in multinomial logistic regression analysis: atopic eczema (OR 2.2, 95% CI 1.2-3.9), onychomycosis (OR 2.0, 1.2-3.2) and rosacea (OR 1.7, 1.1-2.5). After additionally adjusting for body mass index and systemic diseases, the risks for atopic eczema (OR 2.4, 1.3-4.6) and onychomycosis (OR 1.9, 1.1-3.1) remained statistically significant. In conclusion, low grade inflammation is present in several skin diseases.
Ultrasound arthroscopy of human knee cartilage and subchondral bone in vivo.
Liukkonen, Jukka; Lehenkari, Petri; Hirvasniemi, Jukka; Joukainen, Antti; Virén, Tuomas; Saarakkala, Simo; Nieminen, Miika T; Jurvelin, Jukka S; Töyräs, Juha
2014-09-01
Arthroscopic ultrasound imaging enables quantitative evaluation of articular cartilage. However, the potential of this technique for evaluation of subchondral bone has not been investigated in vivo. In this study, we address this issue in clinical arthroscopy of the human knee (n = 11) by determining quantitative ultrasound (9 MHz) reflection and backscattering parameters for cartilage and subchondral bone. Furthermore, in each knee, seven anatomical sites were graded using the International Cartilage Repair Society (ICRS) system based on (i) conventional arthroscopy and (ii) ultrasound images acquired in arthroscopy with a miniature transducer. Ultrasound enabled visualization of articular cartilage and subchondral bone. ICRS grades based on ultrasound images were higher (p < 0.05) than those based on conventional arthroscopy. The higher ultrasound-based ICRS grades were expected as ultrasound reveals additional information on, for example, the relative depth of the lesion. In line with previous literature, ultrasound reflection and scattering in cartilage varied significantly (p < 0.05) along the ICRS scale. However, no significant correlation between ultrasound parameters and structure or density of subchondral bone could be demonstrated. To conclude, arthroscopic ultrasound imaging had a significant effect on clinical grading of cartilage, and it was found to provide quantitative information on cartilage. The lack of correlation between the ultrasound parameters and bone properties may be related to lesser bone change or excessive attenuation in overlying cartilage and insufficient power of the applied miniature transducer. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
León-Pedroza, José Israel; González-Tapia, Luis Alonso; del Olmo-Gil, Esteban; Castellanos-Rodríguez, Diana; Escobedo, Galileo; González-Chávez, Antonio
2015-01-01
Systemic inflammation is characterised by high circulating levels of inflammatory cytokines and increased macrophage infiltration in peripheral tissues. Most importantly, this inflammatory state does not involve damage or loss of function of the infiltrated tissue, which is a distinctive feature of the low-grade systemic inflammation. The term "meta-inflammation" has also been used to refer to the low-grade systemic inflammation due to its strong relationship with the development of cardio-metabolic diseases in obesity. A review is presented on the recent clinical and experimental evidence concerning the role of adipose tissue inflammation as a key mediator of low-grade systemic inflammation. Furthermore, the main molecular mechanisms involved in the inflammatory polarization of macrophages with the ability to infiltrate both the adipose tissue and the vascular endothelium via activation of toll-like receptors by metabolic damage-associated molecular patterns, such as advanced glycation-end products and oxidized lipoproteins, is discussed. Finally, a review is made of the pathogenic mechanisms through which the low-grade systemic inflammation contributes to develop insulin resistance, dyslipidaemia, atherogenesis, type 2 diabetes, and hypertension in obese individuals. A better understanding of the molecular mechanisms of low-grade systemic inflammation in promoting cardio-metabolic diseases is necessary, in order to further design novel anti-inflammatory therapies that take into consideration clinical data, as well as the circulating levels of cytokines, immune cells, and metabolic damage-associated molecular patterns in each patient. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.
Tang, Jie; Li, Wenxiu; Lv, Faqin; Zhang, Huiqin; Zhang, Lihai; Wang, Yuexiang; Li, Junlai; Yang, Li
2009-04-01
To compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with contrast-enhanced computed tomography (CECT) for the detection of different grading of solid organ injuries in blunt abdominal trauma in animals. A self-made miniature tools were used as models to simulate a blunt hepatic or splenic trauma in 16 and 14 anesthetized dogs, respectively. Baseline ultrasound, CEUS and CECT were used to detect traumatic injuries of livers and spleens. The degree of injuries was determined by CEUS according to the American Association for the Surgery of Trauma (AAST) scale and the results compared with injury scale based on CECT evaluation. CEUS showed 22 hepatic injury sites in 16 animals and 17 splenic injury sites in other 14 animals. According to AAST scale, 2 grade I, 4 grade II, 3 grade III, 5 grade IV and 2 grade V hepatic lesions were present in 16 animals; 2 grade I, 4 grade II, 6 grade III and 2 grade IV splenic lesions in 14 animals. On CECT scan, 21 hepatic and 17 splenic injuries were demonstrated. According to Becker CT scaling for hepatic injury, 1 grade I, 2 grade II, 4 grade III, 5 grade IV and 2 grade V hepatic injuries were present. On the basis of Buntain spleen scaling, 2 grade I, 5 grade II, 5 grade III, 2 grade IV splenic injuries were showed. After Spearman rank correlation analysis, the agreement of CEUS with CECT on the degree of hepatic and splenic injury is 93.3% and 92.9%, respectively. CT is currently considered as the reference method for grading blunt abdominal trauma, according to experiment results, CEUS grading showed high levels of concordance with CECT. CEUS can accurately determine the degree of injury and will play an important role in clinical application.
The Arguments and Data in Favor of Minimum Grading
ERIC Educational Resources Information Center
Carifio, James; Carey, Theodore
2013-01-01
The arguments and for and against minimum grading systems have grown increasingly more intense and acrimonious in the past decade. However, there has been an absence of empirical data, theory and clear comparative analyses of conflicting points of view. Critics of minimum grading contend that the practice will produce grade inflation and social…
How Grading Reform Changed Our School
ERIC Educational Resources Information Center
Erickson, Jeffrey A.
2011-01-01
In the early 2000s, Minnetonka High School decided that it needed to develop a more consistent, transparent system of grading. The school focused its grading reform efforts on one principle: Grades should reflect only what a student knows and is able to do. As the school staff analyzed their policies and practices, they discovered many practices…
Teaching with the End in Mind: The Role of Standards-Based Grading
ERIC Educational Resources Information Center
Shippy, Nicole; Washer, Barton A.; Perrin, Billie
2013-01-01
Grading according to standards, competencies, or concepts is nothing new.With the current grading system gaining more scrutiny, parts of the basic framework of how we grade students are being questioned. Stephens (2010) and Marzano and Heflebower (2011) reinforced the notion that homework, behavior, attendance, notebooks, and group work should not…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-08
... Highway-Rail and Pathway Grade Crossings AGENCY: Federal Railroad Administration (FRA), Department of... unsafe conditions at highway-rail and pathway grade crossings. FRA is announcing a public hearing to... and pathway grade crossings. See 76 FR 11992-12012 (March 4, 2011). Interested parties are invited to...
Grades and Incentives: Assessing Competing Grade Point Average Measures and Postgraduate Outcomes
ERIC Educational Resources Information Center
Bailey, Michael A.; Rosenthal, Jeffrey S.; Yoon, Albert H.
2016-01-01
In many educational settings, students may have an incentive to take courses where high grades are easier to achieve, potentially corroding student learning, evaluation of student achievement, and the fairness and efficiency of post-graduation labor outcomes. A grading system that takes into account heterogeneity of teacher standards and student…
Grading Homework to Emphasize Problem-Solving Process Skills
ERIC Educational Resources Information Center
Harper, Kathleen A.
2012-01-01
This article describes a grading approach that encourages students to employ particular problem-solving skills. Some strengths of this method, called "process-based grading," are that it is easy to implement, requires minimal time to grade, and can be used in conjunction with either an online homework delivery system or paper-based homework.
Is the Sky Falling? Grade Inflation and the Signaling Power of Grades
Pattison, Evangeleen; Grodsky, Eric; Muller, Chandra
2014-01-01
Grades are the fundamental currency of our educational system; they signal academic achievement and non-cognitive skills to parents, employers, postsecondary gatekeepers, and students themselves. Grade inflation compromises the signaling value of grades, undermining their capacity to achieve the functions for which they are intended. We challenge the ‘increases in grade point average’ definition of grade inflation and argue that grade inflation must be understood in terms of the signaling power of grades. Analyzing data from four nationally representative samples, we find that in the decades following 1972: (a) grades have risen at high schools and dropped at four-year colleges, in general, and selective four-year institutions, in particular; and (b) the signaling power of grades has attenuated little, if at all. PMID:25288826
Joshi, Vinayak; Agurto, Carla; VanNess, Richard; Nemeth, Sheila; Soliz, Peter; Barriga, Simon
2014-01-01
One of the most important signs of systemic disease that presents on the retina is vascular abnormalities such as in hypertensive retinopathy. Manual analysis of fundus images by human readers is qualitative and lacks in accuracy, consistency and repeatability. Present semi-automatic methods for vascular evaluation are reported to increase accuracy and reduce reader variability, but require extensive reader interaction; thus limiting the software-aided efficiency. Automation thus holds a twofold promise. First, decrease variability while increasing accuracy, and second, increasing the efficiency. In this paper we propose fully automated software as a second reader system for comprehensive assessment of retinal vasculature; which aids the readers in the quantitative characterization of vessel abnormalities in fundus images. This system provides the reader with objective measures of vascular morphology such as tortuosity, branching angles, as well as highlights of areas with abnormalities such as artery-venous nicking, copper and silver wiring, and retinal emboli; in order for the reader to make a final screening decision. To test the efficacy of our system, we evaluated the change in performance of a newly certified retinal reader when grading a set of 40 color fundus images with and without the assistance of the software. The results demonstrated an improvement in reader's performance with the software assistance, in terms of accuracy of detection of vessel abnormalities, determination of retinopathy, and reading time. This system enables the reader in making computer-assisted vasculature assessment with high accuracy and consistency, at a reduced reading time.
Drusco, Alessandra; Bottoni, Arianna; Laganà, Alessandro; Acunzo, Mario; Fassan, Matteo; Cascione, Luciano; Antenucci, Anna; Kumchala, Prasanthi; Vicentini, Caterina; Gardiman, Marina P.; Alder, Hansjuerg; Carosi, Mariantonia A.; Ammirati, Mario; Gherardi, Stefano; Luscrì, Marilena; Carapella, Carmine; Zanesi, Nicola; Croce, Carlo M.
2015-01-01
Central Nervous System malignancies often require stereotactic biopsy or biopsy for differential diagnosis, and for tumor staging and grading. Furthermore, stereotactic biopsy can be non-diagnostic or underestimate grading. Hence, there is a compelling need of new diagnostic biomarkers to avoid such invasive procedures. Several biological markers have been proposed, but they can only identify specific prognostic subtype of Central Nervous System tumors, and none of them has found a standardized clinical application. The aim of the study was to identify a Cerebro-Spinal Fluid microRNA signature that could differentiate among Central Nervous System malignancies. CSF total RNA of 34 neoplastic and of 14 non-diseased patients was processed by NanoString. Comparison among groups (Normal, Benign, Glioblastoma, Medulloblastoma, Metastasis and Lymphoma) lead to the identification of a microRNA profile that was further confirmed by RT-PCR and in situ hybridization. Hsa-miR-451, -711, 935, -223 and -125b were significantly differentially expressed among the above mentioned groups, allowing us to draw an hypothetical diagnostic chart for Central Nervous System malignancies. This is the first study to employ the NanoString technique for Cerebro-Spinal Fluid microRNA profiling. In this article, we demonstrated that Cerebro-Spinal Fluid microRNA profiling mirrors Central Nervous System physiologic or pathologic conditions. Although more cases need to be tested, we identified a diagnostic Cerebro-Spinal Fluid microRNA signature with good perspectives for future diagnostic clinical applications. PMID:26246487
Drusco, Alessandra; Bottoni, Arianna; Laganà, Alessandro; Acunzo, Mario; Fassan, Matteo; Cascione, Luciano; Antenucci, Anna; Kumchala, Prasanthi; Vicentini, Caterina; Gardiman, Marina P; Alder, Hansjuerg; Carosi, Mariantonia A; Ammirati, Mario; Gherardi, Stefano; Luscrì, Marilena; Carapella, Carmine; Zanesi, Nicola; Croce, Carlo M
2015-08-28
Central Nervous System malignancies often require stereotactic biopsy or biopsy for differential diagnosis, and for tumor staging and grading. Furthermore, stereotactic biopsy can be non-diagnostic or underestimate grading. Hence, there is a compelling need of new diagnostic biomarkers to avoid such invasive procedures. Several biological markers have been proposed, but they can only identify specific prognostic subtype of Central Nervous System tumors, and none of them has found a standardized clinical application.The aim of the study was to identify a Cerebro-Spinal Fluid microRNA signature that could differentiate among Central Nervous System malignancies.CSF total RNA of 34 neoplastic and of 14 non-diseased patients was processed by NanoString. Comparison among groups (Normal, Benign, Glioblastoma, Medulloblastoma, Metastasis and Lymphoma) lead to the identification of a microRNA profile that was further confirmed by RT-PCR and in situ hybridization.Hsa-miR-451, -711, 935, -223 and -125b were significantly differentially expressed among the above mentioned groups, allowing us to draw an hypothetical diagnostic chart for Central Nervous System malignancies.This is the first study to employ the NanoString technique for Cerebro-Spinal Fluid microRNA profiling. In this article, we demonstrated that Cerebro-Spinal Fluid microRNA profiling mirrors Central Nervous System physiologic or pathologic conditions. Although more cases need to be tested, we identified a diagnostic Cerebro-Spinal Fluid microRNA signature with good perspectives for future diagnostic clinical applications.
The biochemical, nanomechanical and chemometric signatures of brain cancer
NASA Astrophysics Data System (ADS)
Abramczyk, Halina; Imiela, Anna
2018-01-01
Raman spectroscopy and imaging combined with AFM topography and mechanical indentation by AFM have been shown to be an effective tool for analysis and discrimination of human brain tumors from normal structures. Raman methods have potential to be applied in clinical practice as they allow for identification of tumor margins during surgery. In this study, we investigate medulloblastoma (grade IV WHO) (n = 5) and the tissue from the negative margins used as normal controls. We compare a high grade medulloblastoma (IV grade), and non-tumor samples from human central nervous system (CNS) tissue. Based on the properties of the Raman vibrational spectra and Raman images we provide a real-time feedback that is label-free method to monitor tumor metabolism that reveals reprogramming of biosynthesis of lipids, and proteins. We have found that the high-grade tumors of central nervous system (medulloblastoma) exhibit enhanced level of β-sheet conformation and down-regulated level of α-helix conformation when comparing against normal tissue. We have shown that the ratio of Raman intensities I2930/I2845 at 2930 and 2845 cm- 1 is a good source of information on the ratio of lipid and protein contents. We have found that the ratio reflects the lipid and protein contents of tumorous brain tissue compared to the non-tumor tissue. Almost all brain tumors have the Raman intensity ratios significantly higher (1.99 ± 0.026) than that found in non-tumor brain tissue, which is 1.456 ± 0.02, and indicates that the relative amount of lipids compared to proteins is significantly higher in the normal brain tissue. Mechanical indentation using AFM on sliced human brain tissues (medulloblastoma, grade IV) revealed that the mechanical properties of this tissue are strongly heterogeneous, between 1.8 and 75.7 kPa, and the mean of 27.16 kPa. The sensitivity and specificity obtained directly from PLSDA and cross validation gives a sensitivity and specificity of 98.5% and 96% and 96.3% and 92% for cross-validation, respectively. The high sensitivity and specificity demonstrates usefulness for a proper decision for a Raman diagnostic test on biochemical alterations monitored by Raman spectroscopy related to brain cancer development.
NASA Astrophysics Data System (ADS)
Schweizer, Diane Mary
This research investigated how the use of argument within an earth system science perspective offers potential opportunities for students to develop skills of scientific reasoning. Earth system science views Earth as a synergistic system governed by complex interdependencies between physical and biological spheres. Earth system science presents familiar and compelling societal problems about Earth's environment thereby providing a highly motivational vehicle for engaging students in science. Using global warming as an application of earth system science, my research investigated how middle school and undergraduate students use scientific evidence when constructing and assessing arguments. This dissertation includes three related research studies. The first study took in place in three seventh grade science classrooms and investigated student engagement in a global warming debate. This study illustrated students used evidence to support their central argument; to negate the central argument of the opposing side; to present challenges to the opposing side; and to raise new questions. The second research study is a comparative study and investigated how other students under different instructional settings constructed their arguments on the cause of global warming from the same evidence. This study took place in two seventh grade science classrooms. This study demonstrated that when constructing personal arguments on global warming, students developed an earth system perspective as they considered and integrated different pieces of evidence. Students participating in debate where given a particular view to defend and focused on evidence matching this view, thereby displaying singular views of the cause of global warming. The third research study investigated students abilities to scientifically assess arguments. By analyzing students' written evaluations of arguments on the global climate presented during oral debates, this study demonstrated that undergraduates focus on the overall argument presentation with little attention given to the validity of specific argument components. The primary outcome of these studies is the recommendation that students be provided with opportunities to engage in a variety of argumentation practices, including, but not limited to, debate, constructing arguments reflective of personal views and assessing arguments. Closely coupled with this is the recommendation is that explicit instruction in scientific argumentation accompany classroom activities.
ROMI 3.1 Least-cost lumber grade mix solver using open source statistical software
Rebecca A. Buck; Urs Buehlmann; R. Edward Thomas
2010-01-01
The least-cost lumber grade mix solution has been a topic of interest to both industry and academia for many years due to its potential to help wood processing operations reduce costs. A least-cost lumber grade mix solver is a rough mill decision support system that describes the lumber grade or grade mix needed to minimize raw material or total production cost (raw...
Pitney, Lucy; Weedon, David; Pitney, Michael
2016-08-01
An association between adult scalp seborrhoeic dermatitis and cicatricial hair loss has not previously been convincingly established. This study seeks to demonstrate a unique relationship between a clinically identifiable chronic scalp dermatitis-folliculitis with the characteristic histological features of low-grade inflammatory fibrosing alopecia, resulting in a distinctive progressive cicatricial alopecia which we believe is prevalent and hitherto unrecognised, and befits the description of seborrhoeic folliculitis. The clinical, epidemiological and histopathological features of seborrhoeic folliculitis are demonstrated to establish its unique status among the disorders of adult diffuse cicatricial alopecia. © 2015 The Australasian College of Dermatologists.
Owens, Douglas K; Lohr, Kathleen N; Atkins, David; Treadwell, Jonathan R; Reston, James T; Bass, Eric B; Chang, Stephanie; Helfand, Mark
2010-05-01
To establish guidance on grading strength of evidence for the Evidence-based Practice Center (EPC) program of the U.S. Agency for Healthcare Research and Quality. Authors reviewed authoritative systems for grading strength of evidence, identified domains and methods that should be considered when grading bodies of evidence in systematic reviews, considered public comments on an earlier draft, and discussed the approach with representatives of the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) working group. The EPC approach is conceptually similar to the GRADE system of evidence rating; it requires assessment of four domains: risk of bias, consistency, directness, and precision. Additional domains to be used when appropriate include dose-response association, presence of confounders that would diminish an observed effect, strength of association, and publication bias. Strength of evidence receives a single grade: high, moderate, low, or insufficient. We give definitions, examples, mechanisms for scoring domains, and an approach for assigning strength of evidence. EPCs should grade strength of evidence separately for each major outcome and, for comparative effectiveness reviews, all major comparisons. We will collaborate with the GRADE group to address ongoing challenges in assessing the strength of evidence.
Low-dose endotoxemia and human neuropsychological functions.
Krabbe, Karen Suárez; Reichenberg, Abraham; Yirmiya, Raz; Smed, Annelise; Pedersen, Bente Klarlund; Bruunsgaard, Helle
2005-09-01
Epidemiological data demonstrate an association between systemic low-grade inflammation defined as 2- to 3-fold increases in circulating inflammatory mediators and age-related decline in cognitive function. However, it is not known whether small elevations of circulating cytokine levels cause direct effects on human neuropsychological functions. We investigated changes in emotional, cognitive, and inflammatory parameters in an experimental in vivo model of low-grade inflammation. In a double-blind crossover study, 12 healthy young males completed neuropsychological tests before as well as 1.5, 6, and 24 h after an intravenous injection of Escherichia coli endotoxin (0.2 ng/kg) or saline in two experimental sessions. Endotoxin administration had no effect on body temperature, cortisol levels, blood pressure or heart rate, but circulating levels of tumor necrosis factor (TNF) and interleukin (IL)-6 increased 2- and 7-fold, respectively, reaching peak values at 3 h, whereas soluble TNF-receptors and IL-1 receptor antagonist peaked at 4.5 h. The neutrophil count increased and the lymphocyte count declined. In this model, low-dose endotoxemia did not affect cognitive performance significantly but declarative memory performance was inversely correlated with cytokine increases. In conclusion, our findings demonstrate a negative association between circulating IL-6 and memory functions during very low-dose endotoxemia independently of physical stress symptoms, and the hypothalamo-pituitary-adrenal axis.
Xiong, Jing; Zhou, L I; Lim, Yoon; Yang, Miao; Zhu, Yu-Hong; Li, Zhi-Wei; Fu, Deng-Li; Zhou, Xin-Fu
2015-07-01
There are two forms of brain-derived neurotrophic factor (BDNF), precursor of BDNF (proBDNF) and mature BDNF, which each exert opposing effects through two different transmembrane receptor signaling systems, consisting of p75 neurotrophin receptor (p75NTR) and tyrosine receptor kinase B (TrkB). Previous studies have demonstrated that proBDNF promotes cell death and inhibits the growth and migration of C6 glioma cells through p75NTR in vitro , while mature BDNF has opposite effects on C6 glioma cells. It is hypothesized that mature BDNF is essential in the development of malignancy in gliomas. However, histological data obtained in previous studies were unable distinguish mature BDNF from proBDNF due to the lack of specific antibodies. The present study investigated the expression of mature BDNF using a specific sheep monoclonal anti-mature BDNF antibody in 42 human glioma tissues of different grades and 10 control tissues. The correlation between mature BDNF and TrkB was analyzed. Mature BDNF expression was significantly increased in high-grade gliomas, and was positively correlated with the malignancy of the tumor and TrkB receptor expression. The present data have demonstrated that increased levels of mature BDNF contribute markedly to the development of malignancy of human gliomas through the primary BDNF receptor TrkB.
Ductal carcinoma of breast: nuclear grade as a predictor of S-phase fraction.
Dabbs, D J
1993-06-01
Nuclear grade (NG) and S-phase fraction (SPF) are established independent prognostic variables for ductal breast carcinomas. Nuclear grade can be assigned by a pathologist in a simple fashion during histopathologic evaluation of the tumor, while SPF requires flow cytometric evaluation of tumor samples. This prospective study was undertaken to determine whether elevated SPF could be predicted from NG alone and how NG and SPF correlate with c-erbB-2 expression. Eighty-two breast carcinomas of ductal type were assigned an NG of low (grade 1 or grade 2) or high (grade 3). S-phase fraction was recorded initially from fresh-frozen tissue samples and was designated as either low SPF (below the value designated as the cutoff for elevated SPF) or high SPF (a value at or greater than the cutoff value). On fresh tissue the NG predicted the range of SPF (low or high) in 89% of cases. Four percent of the cases that did not correlate could definitely be attributed to sample error. The remaining 7% that did not correlate could have been due to sample error, specimen quality, or tumor heterogeneity, as demonstrated by reversal of SPF range as performed on paraffin blocks of tumor. Eighty-eight percent of the tumors positive for c-erbB-2 were NG 3 and 12% were NG 2. All c-erbB-2 tumors were aneuploid. This study demonstrates the importance of carefully assigning NGs on tissue and indicates the importance of reviewing flow cytometric data side by side with histopathologic parameters to detect discrepancies between these two modalities. Careful nuclear grading assignment can accurately predict the range of SPF.
A centennial tribute to G.K. Gilbert's Hydraulic Mining Débris in the Sierra Nevada
NASA Astrophysics Data System (ADS)
James, L. A.; Phillips, J. D.; Lecce, S. A.
2017-10-01
G.K. Gilbert's (1917) classic monograph, Hydraulic-Mining Débris in the Sierra Nevada, is described and put into the context of modern geomorphic knowledge. The emphasis here is on large-scale applied fluvial geomorphology, but other key elements-e.g., coastal geomorphology-are also briefly covered. A brief synopsis outlines key elements of the monograph, followed by discussions of highly influential aspects including the integrated watershed perspective, the extreme example of anthropogenic sedimentation, computation of a quantitative, semidistributed sediment budget, and advent of sediment-wave theory. Although Gilbert did not address concepts of equilibrium and grade in much detail, the rivers of the northwestern Sierra Nevada were highly disrupted and thrown into a condition of nonequilibrium. Therefore, concepts of equilibrium and grade-for which Gilbert's early work is often cited-are discussed. Gilbert's work is put into the context of complex nonlinear dynamics in geomorphic systems and how these concepts can be used to interpret the nonequilibrium systems described by Gilbert. Broad, basin-scale studies were common in the period, but few were as quantitative and empirically rigorous or employed such a range of methodologies as PP105. None demonstrated such an extreme case of anthropogeomorphic change.
Develop a PWL System for Dense Graded Hot Mix Asphalt Construction, Including Pay Factors
DOT National Transportation Integrated Search
2015-01-01
This research project developed a PWL system that the Nevada DOT can effectively implement on the construction of dense graded HMA mixtures. The PWL system includes pay factors that are based on pavement performance indicators such as rutting and cra...
Finite Element Modelling Full Vehicle Side Impact with Ultrahigh Strength Hot Stamped Steels
NASA Astrophysics Data System (ADS)
Taylor, T.; Fourlaris, G.; Cafolla, J.
2016-10-01
"Hot stamped boron steel" 22MnB5 has been imperative in meeting the automotive industry's demand for materials exhibiting higher tensile strength in the final component. In this paper, the crash performance of three experimental grades developed for automotive hot stamping technologies, exhibiting wider tensile property ranges than 22MnB5, was validated by finite element modelling full vehicle side impact with the experimental material data applied to the B-pillar reinforcement. The superior anti-intrusive crash performance of grade 38MnB5 was demonstrated, with 11 mm less intrusion of the B-pillar reinforcement compared to 22MnB5. Moreover, the superior "impact-energy absorptive" crash performance of grade 15MnCr5 was demonstrated, with 0.15 kJ greater impact-energy absorption by the B-pillar reinforcement compared to 22MnB5.
Graded Alternating-Time Temporal Logic
NASA Astrophysics Data System (ADS)
Faella, Marco; Napoli, Margherita; Parente, Mimmo
Graded modalities enrich the universal and existential quantifiers with the capability to express the concept of at least k or all but k, for a non-negative integer k. Recently, temporal logics such as μ-calculus and Computational Tree Logic, Ctl, augmented with graded modalities have received attention from the scientific community, both from a theoretical side and from an applicative perspective. Both μ-calculus and Ctl naturally apply as specification languages for closed systems: in this paper, we add graded modalities to the Alternating-time Temporal Logic (Atl) introduced by Alur et al., to study how these modalities may affect specification languages for open systems.
Academic success or failure in nursing students: results of a retrospective observational study.
Lancia, Loreto; Petrucci, Cristina; Giorgi, Fabio; Dante, Angelo; Cifone, Maria Grazia
2013-12-01
Nursing student academic failure is a phenomenon of growing international interest, not only because of its economic impact but also because it negatively affects the availability of future nurses in different healthcare systems. To recruit the students with the highest probability of academic success, an open challenge for universities is to recruit students who have previously demonstrated superior scholastic aptitudes that appear to be associated with a greater likelihood of academic success. Documenting the relationship between the selection methods used when selecting nursing students and academic failure will contribute to the international debate concerning the optimisation of the selection strategies. The principal aim of this study was to investigate the role in predicting nursing student academic success of (1) the upper-secondary diploma grades and (2) the score obtained by students in the nursing degree program admission test. A retrospective observational study was conducted. Five cohorts of nursing students, matriculated in consecutive academic years from 2004 to 2008, in an Italian bachelor's degree program were observed retrospectively. Overall, 61.2% of the 1006 considered students concluded their degree within the legal duration allowed for the nursing degree. Students who failed were those who had lowest grades associated with their upper-secondary diploma coursework (p=0.000) and were male (p=0.000). The grades associated with the upper-secondary diploma coursework, unlike the admission test score, correlates positively with the final degree grade and the average value of degree program examination scores. No correlation was found between the upper-secondary diploma coursework grades and the scores obtained in the test for the nursing degree program admission test (r=-0.037). These results suggest that upper-secondary diploma coursework grades are a parameter that should receive great consideration, especially in cases where there are planned numbers of incoming nursing degree students. Copyright © 2013 Elsevier Ltd. All rights reserved.
Comparative evaluation of techniques for the manufacturing of dendritic cell-based cancer vaccines
Dohnal, Alexander Michael; Graffi, Sebastian; Witt, Volker; Eichstill, Christina; Wagner, Dagmar; Ul-Haq, Sidrah; Wimmer, Doris; Felzmann, Thomas
2009-01-01
Abstract Manufacturing procedures for cellular therapies are continuously improved with particular emphasis on product safety. We previously developed a dendritic cell (DC) cancer vaccine technology platform that uses clinical grade lipopolysaccharide (LPS) and interferon (IFN)-y for the maturation of monocyte derived DCs. DCs are frozen after 6 hrs exposure at a semi-mature stage (smDCs) retaining the capacity to secret interleukin (IL)-12 and thus support cytolytic T-cell responses, which is lost at full maturation. We compared closed systems for monocyte enrichment from leucocyte apheresis products from healthy individuals using plastic adherence, CD14 selection, or CD2/19 depletion with magnetic beads, or counter flow centrifugation (elutriation) using a clinical grade in comparison to a research grade culture medium for the following DC generation. We found that elutriation was superior compared to the other methods showing 36 ± 4% recovery, which was approximately 5-fold higher as the most frequently used adherence protocol (8 ± 1%), and a very good purity (92 ± 5%) of smDCs. Immune phenotype and IL-12 secretion (adherence: 1.4 ± 0.4; selection: 20 ± 0.6; depletion: 1 ±0.5; elutriation: 3.6 ± 1.5 ng/ml) as well as the potency of all DCs to stimulate T cells in an allogeneic mixed leucocyte reaction did not show statistically significant differences. Research grade and clinical grade DC culture media were equally potent and freezing did not impair the functions of smDCs. Finally, we assessed the functional capacity of DC cancer vaccines manufactured for three patients using this optimized procedure thereby demonstrating the feasibility of manufacturing DC cancer vaccines that secret IL-12 (9.4 ± 6.4 ng/ml). We conclude that significant steps were taken here towards clinical grade DC cancer vaccine manufacturing. PMID:18363835
ERIC Educational Resources Information Center
Acat, M. Bahaddin; Demiral, Hilmi; Kaya, Mehmet Fatih
2016-01-01
The main purpose of this study is to measure listening comprehension skills of 5th grade school students with the help of web based system. This study was conducted on 5th grade students studying at the primary schools of Eskisehir. The scale used in the process of the study is "Web Based Listening Scale". In the process of the study,…
Use of an Audience Response System (ARS) in a Dual-Campus Classroom Environment
Medina, Patrick J; Wanzer, Donald S; Wilson, Jane E; Er, Nelson; Britton, Mark L
2008-01-01
Objectives To implement an audience response system in a dual-campus classroom that aggregated data during graded (attendance and quizzes) and non-graded classroom activities (formative quizzes, case discussions, examination reviews, and team activities) and explore its strengths, weaknesses, and impact on active learning. Design After extensive research, an appropriate audience response system was selected and implemented in a dual-classroom setting for a third-year required PharmD course. Students were assigned a clicker and training and policies regarding clicker use were reviewed. Activities involving clicker use were carefully planned to simultaneously engage students in both classrooms in real time. Focus groups were conducted with students to gather outcomes data. Assessment Students and faculty members felt that the immediate feedback the automated response system (ARS) provided was most beneficial during non-graded activities. Student anxiety increased with use of ARS during graded activities due to fears regarding technology failure, user error, and academic integrity. Summary ARS is a viable tool for increasing active learning in a doctor of pharmacy (PharmD) program, especially when used for non-graded class activities. Faculty members should proceed cautiously with using ARS for graded classroom activities and develop detailed and documented policies for ARS use. PMID:18483604
Material Structure of a Graded Refractive Index Lens in Decapod Squid
NASA Astrophysics Data System (ADS)
Cai, Jing; Heiney, Paul; Sweeney, Alison
2013-03-01
Underwater vision with a camera-type eye that is simultaneously acute and sensitive requires a spherical lens with a graded distribution of refractive index. Squids have this type of lens, and our previous work has shown that its optical properties are likely achieved with radially variable densities of a single protein with multiple isoforms. Here we measure the spatial organization of this novel protein material in concentric layers of the lens and use these data to suggest possible mechanisms of self-assembly of the proteins into a graded refractive index structure. First, we performed small angle x-ray scattering (SAXS) to study how the protein is spatially organized. Then, molecular dynamic simulation allowed us to correlate structure to the possible dynamics of the system in different regions of the lens. The combination of simulation and SAXS data in this system revealed the likely protein-protein interactions, resulting material structure and its relationship to the observed and variable optical properties of this graded index system. We believe insights into the material properties of the squid lens system will inform the invention of self-assembling graded index devices.
Semiconductor-based narrow-line and high-brilliance 193-nm laser system for industrial applications
NASA Astrophysics Data System (ADS)
Opalevs, D.; Scholz, M.; Stuhler, J.; Gilfert, C.; Liu, L. J.; Wang, X. Y.; Vetter, A.; Kirner, R.; Scharf, T.; Noell, W.; Rockstuhl, C.; Li, R. K.; Chen, C. T.; Voelkel, R.; Leisching, P.
2018-02-01
We present a novel industrial-grade prototype version of a continuous-wave 193 nm laser system entirely based on solid state pump laser technology. Deep-ultraviolet emission is realized by frequency-quadrupling an amplified diode laser and up to 20 mW of optical power were generated using the nonlinear crystal KBBF. We demonstrate the lifetime of the laser system for different output power levels and environmental conditions. The high stability of our setup was proven in > 500 h measurements on a single spot, a crystal shifter multiplies the lifetime to match industrial requirements. This laser improves the relative intensity noise, brilliance, wall-plug efficiency and maintenance cost significantly. We discuss first lithographic experiments making use of this improvement in photon efficiency.