Sample records for grip shape kinetics

  1. Variability of Grip Kinetics during Adult Signature Writing

    PubMed Central

    Ghali, Bassma; Thalanki Anantha, Nayanashri; Chan, Jennifer; Chau, Tom

    2013-01-01

    Grip kinetics and their variation are emerging as important considerations in the clinical assessment of handwriting pathologies, fine motor rehabilitation, biometrics, forensics and ergonomic pen design. This study evaluated the intra- and inter-participant variability of grip shape kinetics in adults during signature writing. Twenty (20) adult participants wrote on a digitizing tablet using an instrumented pen that measured the forces exerted on its barrel. Signature samples were collected over 10 days, 3 times a day, to capture temporal variations in grip shape kinetics. A kinetic topography (i.e., grip shape image) was derived per signature by time-averaging the measured force at each of 32 locations around the pen barrel. The normalized cross correlations (NCC) of grip shape images were calculated within- and between-participants. Several classification algorithms were implemented to gauge the error rate of participant discrimination based on grip shape kinetics. Four different grip shapes emerged and several participants made grip adjustments (change in grip shape or grip height) or rotated the pen during writing. Nonetheless, intra-participant variation in grip kinetics was generally much smaller than inter-participant force variations. Using the entire grip shape images as a 32-dimensional input feature vector, a K-nearest neighbor classifier achieved an error rate of % in discriminating among participants. These results indicate that writers had unique grip shape kinetics that were repeatable over time but distinct from those of other participants. The topographic analysis of grip kinetics may inform the development of personalized interventions or customizable grips in clinical and industrial applications, respectively. PMID:23658812

  2. Variability of grip kinetics during adult signature writing.

    PubMed

    Ghali, Bassma; Thalanki Anantha, Nayanashri; Chan, Jennifer; Chau, Tom

    2013-01-01

    Grip kinetics and their variation are emerging as important considerations in the clinical assessment of handwriting pathologies, fine motor rehabilitation, biometrics, forensics and ergonomic pen design. This study evaluated the intra- and inter-participant variability of grip shape kinetics in adults during signature writing. Twenty (20) adult participants wrote on a digitizing tablet using an instrumented pen that measured the forces exerted on its barrel. Signature samples were collected over 10 days, 3 times a day, to capture temporal variations in grip shape kinetics. A kinetic topography (i.e., grip shape image) was derived per signature by time-averaging the measured force at each of 32 locations around the pen barrel. The normalized cross correlations (NCC) of grip shape images were calculated within- and between-participants. Several classification algorithms were implemented to gauge the error rate of participant discrimination based on grip shape kinetics. Four different grip shapes emerged and several participants made grip adjustments (change in grip shape or grip height) or rotated the pen during writing. Nonetheless, intra-participant variation in grip kinetics was generally much smaller than inter-participant force variations. Using the entire grip shape images as a 32-dimensional input feature vector, a K-nearest neighbor classifier achieved an error rate of 1.2±0.4% in discriminating among participants. These results indicate that writers had unique grip shape kinetics that were repeatable over time but distinct from those of other participants. The topographic analysis of grip kinetics may inform the development of personalized interventions or customizable grips in clinical and industrial applications, respectively.

  3. Writing Forces Associated With Four Pencil Grasp Patterns in Grade 4 Children

    PubMed Central

    Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl

    2013-01-01

    OBJECTIVE. We investigated differences in handwriting kinetics, speed, and legibility among four pencil grasps after a 10-min copy task. METHOD. Seventy-four Grade 4 students completed a handwriting assessment before and after a copy task. Grip and axial forces were measured with an instrumented stylus and force-sensitive tablet. We used multiple linear regression to analyze the relationship between grasp pattern and grip and axial forces. RESULTS. We found no kinetic differences among grasps, whether considered individually or grouped by the number of fingers on the barrel. However, when grasps were grouped according to the thumb position, the adducted grasps exhibited higher mean grip and axial forces. CONCLUSION. Grip forces were generally similar across the different grasps. Kinetic differences resulting from thumb position seemed to have no bearing on speed and legibility. Interventions for handwriting difficulties should focus more on speed and letter formation than on grasp pattern. PMID:23433277

  4. Grip Analysis of Road Surface and Tire Footprint Using FEM

    NASA Astrophysics Data System (ADS)

    Sabri, M.; Abda, S.

    2018-02-01

    Road grip involve a touch between road pavement and the tire tread pattern. The load bearing surface, which depends on pavement roughness and local pressures in the contact patch. This research conducted to develop a Finite element model for simulating the experimentally testing of asphalt in Jl. AH Nasution Medan, North Sumatera Indonesia base on the value of grip coefficient from various tire loads and the various speed of the vehicle during contact to the road. A tire model and road pavement are developed for the analyses the geometry of tire footprint. The results showed that the greater the mass of car will increase grip coefficient. The coefficient of grip on the road surface contact trough the tire footprint strongly influence the kinetic coefficient of friction at certain speeds. Experimentally show that Concrete road grip coefficient of more than 34% compared to the asphalt road at the same IRI parameters (6-8). Kinetic friction coefficient more than 0.33 was obtained in a asphalt path at a speed of 30-40 Km/hour.

  5. Writing forces associated with four pencil grasp patterns in grade 4 children.

    PubMed

    Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl; Chau, Tom

    2013-01-01

    OBJECTIVE. We investigated differences in handwriting kinetics, speed, and legibility among four pencil grasps after a 10-min copy task. METHOD. Seventy-four Grade 4 students completed a handwriting assessment before and after a copy task. Grip and axial forces were measured with an instrumented stylus and force-sensitive tablet. We used multiple linear regression to analyze the relationship between grasp pattern and grip and axial forces. RESULTS. We found no kinetic differences among grasps, whether considered individually or grouped by the number of fingers on the barrel. However, when grasps were grouped according to the thumb position, the adducted grasps exhibited higher mean grip and axial forces. CONCLUSION. Grip forces were generally similar across the different grasps. Kinetic differences resulting from thumb position seemed to have no bearing on speed and legibility. Interventions for handwriting difficulties should focus more on speed and letter formation than on grasp pattern. Copyright © 2013 by the American Occupational Therapy Association, Inc.

  6. Volitional and automatic control of the hand when reaching to grasp objects.

    PubMed

    Chen, Zhongting; Saunders, Jeffrey Allen

    2018-06-01

    When picking up an object, we tend to grasp at contact points that allow a stable grip. Recent studies have demonstrated that appropriate grasp points can be selected during an ongoing movement in response to unexpected perturbations of the target object. In this study, we tested whether such online grip adjustments are automatic responses or can be controlled volitionally. Subjects performed virtual grasping movements toward target 2D shapes that sometimes changed shape or orientation during movement. Unlike in previous studies, the conditions and task requirements discouraged any online adjustments toward the perturbed shapes. In Experiment 1, target shapes were perturbed briefly (200 ms) during movement before reverting to the original shape, and subjects were instructed to ignore the transient perturbations. Despite subjects' intentions, we observed online adjustments of grip orientation that were toward the expected grip axis of the briefly presented shape. In Experiment 2, we added a stop-signal to the grasping task, with target perturbation as the stop cue. We again observed unnecessary online adjustments toward the grip axis of the perturbed shape, with similar latency. Furthermore, the grip adjustments continued after the forward motion of the hand had stopped, indicating that the automatic response to the perturbed target shape co-occurred with the volitional response to the perturbation onset. Our results provide evidence that automatic control mechanisms are used to guide the fingers to appropriate grasp points and suggest that these mechanisms are distinct from those involved with volitional control. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  7. Shared processing of planning articulatory gestures and grasping.

    PubMed

    Vainio, L; Tiainen, M; Tiippana, K; Vainio, M

    2014-07-01

    It has been proposed that articulatory gestures are shaped by tight integration in planning mouth and hand acts. This hypothesis is supported by recent behavioral evidence showing that response selection between the precision and power grip is systematically influenced by simultaneous articulation of a syllable. For example, precision grip responses are performed relatively fast when the syllable articulation employs the tongue tip (e.g., [te]), whereas power grip responses are performed relatively fast when the syllable articulation employs the tongue body (e.g., [ke]). However, this correspondence effect, and other similar effects that demonstrate the interplay between grasping and articulatory gestures, has been found when the grasping is performed during overt articulation. The present study demonstrates that merely reading the syllables silently (Experiment 1) or hearing them (Experiment 2) results in a similar correspondence effect. The results suggest that the correspondence effect is based on integration in planning articulatory gestures and grasping rather than requiring an overt articulation of the syllables. We propose that this effect reflects partially overlapped planning of goal shapes of the two distal effectors: a vocal tract shape for articulation and a hand shape for grasping. In addition, the paper shows a pitch-grip correspondence effect in which the precision grip is associated with a high-pitched vocalization of the auditory stimuli and the power grip is associated with a low-pitched vocalization. The underlying mechanisms of this phenomenon are discussed in relation to the articulation-grip correspondence.

  8. The relationship between hand anthropometrics, total grip strength and individual finger force for various handle shapes.

    PubMed

    Kong, Yong-Ku; Kim, Dae-Min

    2015-01-01

    The design and shape of hand tool handles are critical factors for preventing musculoskeletal disorders (MSDs) caused by the use of hand tools. We explored how these factors are related to total force and individual finger force in males and females with various hand anthropometrics. Using the MFFM system, we assessed four indices of anthropometry, and measured total force and individual finger force on various handle designs and shapes. Both total force and individual finger force were significant according to gender and handle shape. Total grip strength to the handle shape indicated the greatest strength with D shape and the least with A shape. From the regression analysis of hand anthropometric indices, the value of R was respectably high at 0.608-0.696. The current study examined the gender and handle shape factors affecting grip strength based on the force measurements from various handle types, in terms of influence on different hand anthropometric indices.

  9. Lifting clamp positively grips structural shapes

    NASA Technical Reports Server (NTRS)

    Reinhardt, E. C.

    1966-01-01

    Welded steel clamps securely grip structural shapes of various sizes for crane operations. The clamp has adjustable clamping jaws and screw-operated internal v-jaws and provides greater safety than hoisting slings presently used. The structural member can be rotated in any manner, angle, or direction without being released by the clamp.

  10. GRIPPING DEVICE FOR CYLINDRICAL OBJECTS

    DOEpatents

    Pilger, J.P.

    1964-01-21

    A gripping device is designed for fragile cylindrical objects such as for drawing thin-walled tubes. The gripping is done by multiple jaw members held in position by two sets of slots, one defined by keystone-shaped extensions of the outer shell of the device and the other in a movable sleeve held slidably by the extensions. Forward movement oi the sleeve advances the jaws, thereby exerting a controlled, radial pressure on the object being gripped. (AEC)

  11. Comprehension of handwriting development: Pen-grip kinetics in handwriting tasks and its relation to fine motor skills among school-age children.

    PubMed

    Lin, Yu-Chen; Chao, Yen-Li; Wu, Shyi-Kuen; Lin, Ho-Hsio; Hsu, Chieh-Hsiang; Hsu, Hsiao-Man; Kuo, Li-Chieh

    2017-10-01

    Numerous tools have been developed to evaluate handwriting performances by analysing written products. However, few studies have directly investigated kinetic performances of digits when holding a pen. This study thus attempts to investigate pen-grip kinetics during writing tasks of school-age children and explore the relationship between the kinetic factors and fine motor skills. This study recruited 181 children aged from 5 to 12 years old and investigated the effects of age on handwriting kinetics and the relationship between these and fine motor skills. The forces applied from the digits and pen-tip were measured during writing tasks via a force acquisition pen, and the children's fine motor performances were also evaluated. The results indicate that peak force and average force might not be direct indicators of handwriting performance for normally developing children at this age. Younger children showed larger force variation and lower adjustment frequency during writing, which might indicate they had poorer force control than the older children. Force control when handling a pen is significantly correlated with fine motor performance, especially in relation to the manual dexterity. A novel system is proposed for analysing school-age children's force control while handwriting. We observed the development of force control in relation to pen grip among the children with different ages in this study. The findings suggested that manipulation skill may be crucial when children are establishing their handwriting capabilities. © 2017 Occupational Therapy Australia.

  12. GRIPs (Group Investigation Problems) for Introductory Physics

    NASA Astrophysics Data System (ADS)

    Moore, Thomas A.

    2006-12-01

    GRIPs lie somewhere between homework problems and simple labs: they are open-ended questions that require a mixture of problem-solving skills and hands-on experimentation to solve practical puzzles involving simple physical objects. In this talk, I will describe three GRIPs that I developed for a first-semester introductory calculus-based physics course based on the "Six Ideas That Shaped Physics" text. I will discuss the design of the three GRIPs we used this past fall, our experience in working with students on these problems, and students' response as reported on course evaluations.

  13. Hand shape selection in pantomimed grasping: Interaction between the dorsal and the ventral visual streams and convergence on the ventral premotor area

    PubMed Central

    Makuuchi, Michiru; Someya, Yoshiaki; Ogawa, Seiji; Takayama, Yoshihiro

    2011-01-01

    In visually guided grasping, possible hand shapes are computed from the geometrical features of the object, while prior knowledge about the object and the goal of the action influence both the computation and the selection of the hand shape. We investigated the system dynamics of the human brain for the pantomiming of grasping with two aspects accentuated. One is object recognition, with the use of objects for daily use. The subjects mimed grasping movements appropriate for an object presented in a photograph either by precision or power grip. The other is the selection of grip hand shape. We manipulated the selection demands for the grip hand shape by having the subjects use the same or different grip type in the second presentation of the identical object. Effective connectivity analysis revealed that the increased selection demands enhance the interaction between the anterior intraparietal sulcus (AIP) and posterior inferior temporal gyrus (pITG), and drive the converging causal influences from the AIP, pITG, and dorsolateral prefrontal cortex to the ventral premotor area (PMv). These results suggest that the dorsal and ventral visual areas interact in the pantomiming of grasping, while the PMv integrates the neural information of different regions to select the hand posture. The present study proposes system dynamics in visually guided movement toward meaningful objects, but further research is needed to examine if the same dynamics is found also in real grasping. PMID:21739528

  14. Evolution of the human hand: approaches to acquiring, analysing and interpreting the anatomical evidence

    PubMed Central

    MARZKE, MARY W.; MARZKE, R. F.

    2000-01-01

    The discovery of fossil hand bones from an early human ancestor at Olduvai Gorge in 1960, at the same level as primitive stone tools, generated a debate about the role of tools in the evolution of the human hand that has raged to the present day. Could the Olduvai hand have made the tools? Did the human hand evolve as an adaptation to tool making and tool use? The debate has been fueled by anatomical studies comparing living and fossil human and nonhuman primate hands, and by experimental observations. These have assessed the relative abilities of apes and humans to manufacture the Oldowan tools, but consensus has been hampered by disagreements about how to translate experimental data from living species into quantitative models for predicting the performance of fossil hands. Such models are now beginning to take shape as new techniques are applied to the capture, management and analysis of data on kinetic and kinematic variables ranging from hand joint structure, muscle mechanics, and the distribution and density of bone to joint movements and muscle recruitment during manipulative behaviour. The systematic comparative studies are highlighting a functional complex of features in the human hand facilitating a distinctive repertoire of grips that are apparently more effective for stone tool making than grips characterising various nonhuman primate species. The new techniques are identifying skeletal variables whose form may provide clues to the potential of fossil hominid hands for one-handed firm precision grips and fine precision manoeuvering movements, both of which are essential for habitual and effective tool making and tool use. PMID:10999274

  15. The effect of hand dimensions, hand shape and some anthropometric characteristics on handgrip strength in male grip athletes and non-athletes.

    PubMed

    Fallahi, Ali Asghar; Jadidian, Ali Akbar

    2011-09-01

    It has been suggested that athletes with longer fingers and larger hand surfaces enjoy stronger grip power. Therefore, some researchers have examined a number of factors and anthropometric variables that explain this issue. To our knowledge, the data is scarce. Thus, the aim of this study was to investigate the effect of hand dimensions, hand shape and some anthropometric characteristics on handgrip strength in male grip athletes and non-athletes. 80 subjects aged between 19 and 29 participated in this study in two groups including: national and collegian grip athletes (n=40), and non-athletes (n=40). Body height and mass were measured to calculate body mass index. The shape of the dominant hand was drawn on a piece of paper with a thin marker so that finger spans, finger lengths, and perimeters of the hand could be measured. The hand shape was estimated as the ratio of the hand width to hand length. Handgrip strength was measured in the dominant and non-dominant hand using a standard dynamometer. Descriptive statistics were used for each variable and independent t test was used to analyze the differences between the two groups. The Pearson correlation coefficient test was used to evaluate the correlation between studied variables. Also, to predict important variables in handgrip strength, the linear trend was assessed using a linear regression analysis. There was a significant difference between the two groups in absolute handgrip strength (p<0.001) and handgrip/height ratio (p<0.001). The indices of body height, body mass, lean body mass and body fat content (p<0.001) were significantly greater in grip athletes. All hand variables except FS1-4 (p>0.05) were significantly different between the groups (p<0.001). After controlling body mass all hand anthropometric characteristics except thumb length (r=0.240, p= 0.135), hand shape (r=-0.029, p=0.858), middle finger length (r=0.305, p=0.056) and forearm circumference (r=0.162, p=0.319) significantly correlated with handgrip strength in grip athletes, but not in non-athletes, except for forearm circumference (r=0.406, p=0.010). The results showed that handgrip strength and some of the hand dimensions may be different in athletes who have handgrip movements with an object or opponent in comparison to non-athletes. Also, there was a significant positive correlation between handgrip strength and most of the hand dimensions in grip athletes. Therefore, these can be used in talent identification in handgrip-related sports and in clinical settings as well.

  16. The Effect of Hand Dimensions, Hand Shape and Some Anthropometric Characteristics on Handgrip Strength in Male Grip Athletes and Non-Athletes

    PubMed Central

    Fallahi, Ali Asghar; Jadidian, Ali Akbar

    2011-01-01

    It has been suggested that athletes with longer fingers and larger hand surfaces enjoy stronger grip power. Therefore, some researchers have examined a number of factors and anthropometric variables that explain this issue. To our knowledge, the data is scarce. Thus, the aim of this study was to investigate the effect of hand dimensions, hand shape and some anthropometric characteristics on handgrip strength in male grip athletes and non-athletes. 80 subjects aged between 19 and 29 participated in this study in two groups including: national and collegian grip athletes (n=40), and non-athletes (n=40). Body height and mass were measured to calculate body mass index. The shape of the dominant hand was drawn on a piece of paper with a thin marker so that finger spans, finger lengths, and perimeters of the hand could be measured. The hand shape was estimated as the ratio of the hand width to hand length. Handgrip strength was measured in the dominant and non-dominant hand using a standard dynamometer. Descriptive statistics were used for each variable and independent t test was used to analyze the differences between the two groups. The Pearson correlation coefficient test was used to evaluate the correlation between studied variables. Also, to predict important variables in handgrip strength, the linear trend was assessed using a linear regression analysis. There was a significant difference between the two groups in absolute handgrip strength (p<0.001) and handgrip/height ratio (p<0.001). The indices of body height, body mass, lean body mass and body fat content (p<0.001) were significantly greater in grip athletes. All hand variables except FS1-4 (p>0.05) were significantly different between the groups (p<0.001). After controlling body mass all hand anthropometric characteristics except thumb length (r=0.240, p= 0.135), hand shape (r=−0.029, p=0.858), middle finger length (r=0.305, p=0.056) and forearm circumference (r=0.162, p=0.319) significantly correlated with handgrip strength in grip athletes, but not in non-athletes, except for forearm circumference (r=0.406, p=0.010). The results showed that handgrip strength and some of the hand dimensions may be different in athletes who have handgrip movements with an object or opponent in comparison to non-athletes. Also, there was a significant positive correlation between handgrip strength and most of the hand dimensions in grip athletes. Therefore, these can be used in talent identification in handgrip-related sports and in clinical settings as well. PMID:23486361

  17. Enslaving in a serial chain: interactions between grip force and hand force in isometric tasks.

    PubMed

    Paclet, Florent; Ambike, Satyajit; Zatsiorsky, Vladimir M; Latash, Mark L

    2014-03-01

    This study was motivated by the double action of extrinsic hand muscles that produce grip force and also contribute to wrist torque. We explored interactions between grip force and wrist torque in isometric force production tasks. In particular, we tested a hypothesis that an intentional change in one of the two kinetic variables would produce an unintentional change in the other (enslaving). When young healthy subjects produced accurate changes in the grip force, only minor effects on the force produced by the hand (by wrist flexion/extension action) were observed. In contrast, a change in the hand force produced consistent changes in grip force in the same direction. The magnitude of such unintentional grip force change was stronger for intentional hand force decrease as compared to hand force increase. These effects increased with the magnitude of the initial grip force. When the subjects were asked to produce accurate total force computed as the sum of the hand and grip forces, strong negative covariation between the two forces was seen across trials interpreted as a synergy stabilizing the total force. An index of this synergy was higher in the space of "modes," hypothetical signals to the two effectors that could be changed by the controller one at a time. We interpret the complex enslaving effects (positive force covariation) as conditioned by typical everyday tasks. The presence of synergic effects (negative, task-specific force covariation) can be naturally interpreted within the referent configuration hypothesis.

  18. Enslaving in a serial chain: Interactions between grip force and hand force in isometric tasks

    PubMed Central

    Paclet, Florent; Ambike, Satyajit; Zatsiorsky, Vladimir M.; Latash, Mark L.

    2014-01-01

    This study was motivated by the double action of extrinsic hand muscles that produce grip force and also contribute to wrist torque. We explored interactions between grip force and wrist torque in isometric force production tasks. In particular, we tested a hypothesis that an intentional change in one of the two kinetic variables would produce an unintentional change in the other (enslaving). When young healthy subjects produced accurate changes in the grip force, only minor effects on the force produced by the hand (by wrist flexion/extension action) were observed. In contrast, a change in the hand force produced consistent changes in grip force in the same direction. The magnitude of such unintentional grip force change was stronger for intentional hand force decrease as compared to hand force increase. These effects increased with the magnitude of the initial grip force. When the subjects were asked to produce accurate total force computed as the sum of the hand and grip forces, strong negative co-variation between the two forces was seen across trials interpreted as a synergy stabilizing the total force. An index of this synergy was higher in the space of “modes”, hypothetical signals to the two effectors that could be changed by the controller one at a time. We interpret the complex enslaving effects (positive force co-variation) as conditioned by typical everyday tasks. The presence of synergic effects (negative, task-specific force co-variation) can be naturally interpreted within the referent configuration hypothesis. PMID:24309747

  19. Soft shape-adaptive gripping device made from artificial muscle

    NASA Astrophysics Data System (ADS)

    Hamburg, E.; Vunder, V.; Johanson, U.; Kaasik, F.; Aabloo, A.

    2016-04-01

    We report on a multifunctional four-finger gripper for soft robotics, suitable for performing delicate manipulation tasks. The gripping device is comprised of separately driven gripping and lifting mechanisms, both made from a separate single piece of smart material - ionic capacitive laminate (ICL) also known as artificial muscle. Compared to other similar devices the relatively high force output of the ICL material allows one to construct a device able to grab and lift objects exceeding multiple times its own weight. Due to flexible design of ICL grips, the device is able to adapt the complex shapes of different objects and allows grasping single or multiple objects simultaneously without damage. The performance of the gripper is evaluated in two different configurations: a) the ultimate grasping strength of the gripping hand; and b) the maximum lifting force of the lifting actuator. The ICL is composed of three main layers: a porous membrane consisting of non-ionic polymer poly(vinylidene fluoride-co-hexafluoropropene) (PVdF-HFP), ionic liquid 1-ethyl-3-methylimidazolium trifluoromethane-sulfonate (EMITFS), and a reinforcing layer of woven fiberglass cloth. Both sides of the membrane are coated with a carbonaceous electrode. The electrodes are additionally covered with thin gold layers, serving as current collectors. Device made of this material operates silently, requires low driving voltage (<3 V), and is suitable for performing tasks in open air environment.

  20. Handle grip span for optimising finger-specific force capability as a function of hand size.

    PubMed

    Lee, Soo-Jin; Kong, Yong-Ku; Lowe, Brian D; Song, Seongho

    2009-05-01

    Five grip spans (45 to 65 mm) were tested to evaluate the effects of handle grip span and user's hand size on maximum grip strength, individual finger force and subjective ratings of comfort using a computerised digital dynamometer with independent finger force sensors. Forty-six males participated and were assigned into three hand size groups (small, medium, large) according to their hands' length. In general, results showed the 55- and 50-mm grip spans were rated as the most comfortable sizes and showed the largest grip strength (433.6 N and 430.8 N, respectively), whereas the 65-mm grip span handle was rated as the least comfortable size and the least grip strength. With regard to the interaction effect of grip span and hand size, small and medium-hand participants rated the best preference for the 50- to 55-mm grip spans and the least for the 65-mm grip span, whereas large-hand participants rated the 55- to 60-mm grip spans as the most preferred and the 45-mm grip span as the least preferred. Normalised grip span (NGS) ratios (29% and 27%) are the ratios of user's hand length to handle grip span. The NGS ratios were obtained and applied for suggesting handle grip spans in order to maximise subjective comfort as well as gripping force according to the users' hand sizes. In the analysis of individual finger force, the middle finger force showed the highest contribution (37.5%) to the total finger force, followed by the ring (28.7%), index (20.2%) and little (13.6%) finger. In addition, each finger was observed to have a different optimal grip span for exerting the maximum force, resulting in a bow-contoured shaped handle (the grip span of the handle at the centre is larger than the handle at the end) for two-handle hand tools. Thus, the grip spans for two-handle hand tools may be designed according to the users' hand/finger anthropometrics to maximise subjective ratings and performance based on this study. Results obtained in this study will provide guidelines for hand tool designers and manufacturers for designing grip spans of two-handle tools, which can maximise handle comfort and performance.

  1. Gloss, colour and grip: multifunctional epidermal cell shapes in bee- and bird-pollinated flowers.

    PubMed

    Papiorek, Sarah; Junker, Robert R; Lunau, Klaus

    2014-01-01

    Flowers bear the function of filters supporting the attraction of pollinators as well as the deterrence of floral antagonists. The effect of epidermal cell shape on the visual display and tactile properties of flowers has been evaluated only recently. In this study we quantitatively measured epidermal cell shape, gloss and spectral reflectance of flowers pollinated by either bees or birds testing three hypotheses: The first two hypotheses imply that bee-pollinated flowers might benefit from rough surfaces on visually-active parts produced by conical epidermal cells, as they may enhance the colour signal of flowers as well as the grip on flowers for bees. In contrast, bird-pollinated flowers might benefit from flat surfaces produced by flat epidermal cells, by avoiding frequent visitation from non-pollinating bees due to a reduced colour signal, as birds do not rely on specific colour parameters while foraging. Moreover, flat petal surfaces in bird-pollinated flowers may hamper grip for bees that do not touch anthers and stigmas while consuming nectar and thus, are considered as nectar thieves. Beside this, the third hypothesis implies that those flower parts which are vulnerable to nectar robbing of bee- as well as bird-pollinated flowers benefit from flat epidermal cells, hampering grip for nectar robbing bees. Our comparative data show in fact that conical epidermal cells are restricted to visually-active parts of bee-pollinated flowers, whereas robbing-sensitive parts of bee-pollinated as well as the entire floral surface of bird-pollinated flowers possess on average flat epidermal cells. However, direct correlations between epidermal cell shape and colour parameters have not been found. Our results together with published experimental studies show that epidermal cell shape as a largely neglected flower trait might act as an important feature in pollinator attraction and avoidance of antagonists, and thus may contribute to the partitioning of flower-visitors.

  2. Nonspherical femoral head shape (pistol grip deformity), neck shaft angle, and risk of hip osteoarthritis: a case-control study.

    PubMed

    Doherty, Michael; Courtney, Philip; Doherty, Sally; Jenkins, Wendy; Maciewicz, Rose A; Muir, Kenneth; Zhang, Weiya

    2008-10-01

    To determine whether 2-dimensional measures of femoral head shape and angle are associated with hip osteoarthritis (OA). We compared cases with symptomatic radiographic hip OA with asymptomatic controls with no radiographic hip OA. On anteroposterior pelvis radiographs, we measured "pistol grip deformity" for each hip (visually categorized as nonspherical, indeterminate, or spherical), the femoral head-to-femoral neck ratio as an interval measure of femoral head shape, and the femoral neck shaft angle. The relative risk of hip OA associated with each feature was estimated using odds ratios (ORs) and 95% confidence intervals (95% CIs), adjusted for possible confounders using a logistic regression model. Of 1,007 cases, 965 had definite radiographic hip OA; of 1,123 controls, 1,111 had no radiographic OA. The prevalence of pistol grip deformity in at least 1 hip was 3.61% in controls and 17.71% in cases (OR 6.95 [95% CI 4.64-10.41]), and the prevalence of abnormal femoral head-to-femoral neck ratio in at least 1 hip was 3.70% in controls and 24.27% in cases (OR 12.08 [95% CI 8.05-18.15]). The risk of hip OA increased as the femoral head-to-femoral neck ratio decreased (P for trend<0.001) and with each extreme of neck shaft angle (P<0.05). In cases with unilateral hip OA, the prevalence of abnormal femoral head-to-femoral neck ratio in the unaffected hip was 2 times greater than that in controls (OR 1.82 [95% CI 1.07-3.07]); in contrast, an abnormally low, but not abnormally high, neck shaft angle was more common in unaffected hips than in controls (OR 1.79 [95% CI 1.03-3.14]). Our findings indicate that pistol grip deformity is associated with hip OA. The increased prevalence of pistol grip deformity and an abnormally low neck shaft angle in unaffected hips of cases with unilateral OA suggests that they are risk factors for development of hip OA. However, both a nonspherical head shape and an increase in neck shaft angle may occur as a consequence of OA.

  3. Relationship between performance variables and baseball ability in youth baseball players.

    PubMed

    Nakata, Hiroki; Nagami, Tomoyuki; Higuchi, Takatoshi; Sakamoto, Kiwako; Kanosue, Kazuyuki

    2013-10-01

    The present study investigated the relationship of performance variables and anthropometric measurements on baseball ability in 164 youth baseball players (age: 6.4-15.7 years). To evaluate their baseball performance, ball speeds in pitching and batting were recorded and kinetic energies of the pitched and hit balls were calculated. To record anthropometric and physical fitness characteristics, height and weight were measured and a battery of physical fitness tests covering standing long jump, side steps, sit-ups, 10-m sprint, trunk flexion, back strength, and grip strengths of both hands were conducted. The results of a multiple regression analysis revealed several significant predictors: age, body mass index (BMI), standing long jump, 10-m sprint, and grip strength for pitched ball kinetic energy and age, BMI, standing long jump, and back strength for hit ball kinetic energy. This study provides scientific evidence that relates certain specific physical performance tests and body characteristics with high achievement in the actual performance of pitching and batting. Youth players, their parents, coaches, and trainers would benefit by addressing these characteristics when planning training programs to improve the baseball performance of youth players.

  4. Development of a Prototype Over-Actuated Biomimetic Prosthetic Hand

    PubMed Central

    Williams, Matthew R.; Walter, Wayne

    2015-01-01

    The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results. PMID:25790306

  5. The determination of the operating range of a twin-grip control yoke through biomechanical means

    NASA Technical Reports Server (NTRS)

    Gaertner, K. P.

    1978-01-01

    A twin-grip control yoke was designed as an ergonomic case study that allows dual axis control inputs, both axes being rotational. Inputs are effected by rotating the grips. How the handles were designed with respect to their shape and size and how the angular range of the control yoke in both rotational axes was evaluated. The control yoke which requires two-hand operation was tested to determine its operating range. The intention of this investigation was to find out the optimal form of the control yoke and the maximum permissible range in both rotating axes. In these experiments controls had no spring resistance.

  6. Hand grip strength in the adult Malaysian population.

    PubMed

    Kamarul, T; Ahmad, T S; Loh, W Y C

    2006-08-01

    To measure the hand grip strength of Malaysians aged 18 to 65 years. Between January and April 2003, 412 subjects (200 women and 212 men) were recruited from staff, students, and visitors of the University of Malaya Medical Centre. Socioeconomic, general health, and lifestyle data were collected from each subject using a standard questionnaire. Weight and height were measured prior to testing. Standardised positioning and instructions based on several hand grip protocols were used. Data were collected using the LIDO kinetic work set. 93% of the subjects were right-hand dominant and 7% were left-hand dominant. Hand grip strength was significantly correlated with hand dominance, gender, occupation, height, and weight, but not body mass index. No significant differences in grip strength were noted with regard to race or level of income. Men were stronger than women in all age-groups, with a ratio of 1.75:1. In both right- and left-hand dominant groups, the dominant hand was consistently stronger than the non-dominant side, with a ratio of 1.12:1 in the right-hand dominant group and 1.05:1 in the left-hand dominant group. The strongest hand grip strength in the right-hand dominant group occurred in the age-group of 25 to 34 years; in the left-hand dominant group it was in the age-group of 18 to 24 years. In western populations, the mean grip strength can be as much as 1.5 times greater than in the Malaysian population. Data derived from western populations cannot be applied to a comparable Malaysian population. Gender, hand dominance, age, occupation, weight, and height must be considered when establishing normal values for grip strength.

  7. Design and implementation of a multiaxial loading capability during heating on an engineering neutron diffractometer.

    PubMed

    Benafan, O; Padula, S A; Skorpenske, H D; An, K; Vaidyanathan, R

    2014-10-01

    A gripping capability was designed, implemented, and tested for in situ neutron diffraction measurements during multiaxial loading and heating on the VULCAN engineering materials diffractometer at the spallation neutron source at Oak Ridge National Laboratory. The proposed capability allowed for the acquisition of neutron spectra during tension, compression, torsion, and/or complex loading paths at elevated temperatures. The design consisted of age-hardened, Inconel(®) 718 grips with direct attachment to the existing MTS load frame having axial and torsional capacities of 100 kN and 400 N·m, respectively. Internal cooling passages were incorporated into the gripping system for fast cooling rates during high temperature experiments up to ∼1000 K. The specimen mounting couplers combined a threaded and hexed end-connection for ease of sample installation/removal without introducing any unwanted loads. Instrumentation of this capability is documented in this work along with various performance parameters. The gripping system was utilized to investigate deformation in NiTi shape memory alloys under various loading/control modes (e.g., isothermal, isobaric, and cyclic), and preliminary results are presented. The measurements facilitated the quantification of the texture, internal strain, and phase fraction evolution in NiTi shape memory alloys under various loading/control modes.

  8. Design and implementation of a multiaxial loading capability during heating on an engineering neutron diffractometer

    NASA Astrophysics Data System (ADS)

    Benafan, O.; Padula, S. A.; Skorpenske, H. D.; An, K.; Vaidyanathan, R.

    2014-10-01

    A gripping capability was designed, implemented, and tested for in situ neutron diffraction measurements during multiaxial loading and heating on the VULCAN engineering materials diffractometer at the spallation neutron source at Oak Ridge National Laboratory. The proposed capability allowed for the acquisition of neutron spectra during tension, compression, torsion, and/or complex loading paths at elevated temperatures. The design consisted of age-hardened, Inconel® 718 grips with direct attachment to the existing MTS load frame having axial and torsional capacities of 100 kN and 400 N.m, respectively. Internal cooling passages were incorporated into the gripping system for fast cooling rates during high temperature experiments up to ˜1000 K. The specimen mounting couplers combined a threaded and hexed end-connection for ease of sample installation/removal without introducing any unwanted loads. Instrumentation of this capability is documented in this work along with various performance parameters. The gripping system was utilized to investigate deformation in NiTi shape memory alloys under various loading/control modes (e.g., isothermal, isobaric, and cyclic), and preliminary results are presented. The measurements facilitated the quantification of the texture, internal strain, and phase fraction evolution in NiTi shape memory alloys under various loading/control modes.

  9. An inverted J-shaped association of serum uric acid with muscle strength among Japanese adult men: a cross-sectional study

    PubMed Central

    2013-01-01

    Background Uric acid (UA) may protect muscle function from oxidative damage due to reactive oxygen species through its powerful antioxidant capacity. However, several studies have demonstrated that hyperuricemia is closely related to systemic inflammation and has oxidant properties effects, both of which may increase the risk of muscle strength loss. The purpose of this study was to examine the association of serum UA concentration with grip strength and leg extension power in adult men. Methods This study is a cross-sectional survey in which 630 Japanese male employees aged 30 years and older participated. Five hundred and eighty-six subjects participated in the measurement of grip strength, and 355 subjects participated in the measurement of leg extension power. Blood samples were obtained for serum UA analysis. Results After adjustment for potential confounders, grip strength differed significantly between participants with and those without hyperuricemia (geometric mean and 95% confidence interval [CI]: 40.3 [39.2–41.3] kg vs. 41.9 [41.3–42.5] kg; P = 0.01). In addition, serum UA levels (quartiles) showed an inverted J-shaped curve with grip strength (mean and 95% CI: Q1, 41.6 [40.6–42.6] kg; Q2, 42.2 [41.2–43.2] kg; Q3, 41.8 [40.8–42.8] kg; Q4, 40.4 [39.3–41.4] kg; P for quadratic trend = 0.05). The results in the leg extension power group were similar to those observed in the grip strength group. Conclusion This population-based cross-sectional study shows for the first time that hyperuricemia is associated with poor muscle strength. Moreover, the results indicate an inverted J-shaped association between serum UA quartiles and muscle strength. PMID:24000893

  10. Analysis of the pen pressure and grip force signal during basic drawing tasks: The timing and speed changes impact drawing characteristics.

    PubMed

    Gatouillat, Arthur; Dumortier, Antoine; Perera, Subashan; Badr, Youakim; Gehin, Claudine; Sejdić, Ervin

    2017-08-01

    Writing is a complex fine and trained motor skill, involving complex biomechanical and cognitive processes. In this paper, we propose the study of writing kinetics using three angles: the pen-tip normal force, the total grip force signal and eventually writing quality assessment. In order to collect writing kinetics data, we designed a sensor collecting these characteristics simultaneously. Ten healthy right-handed adults were recruited and were asked to perform four tasks: first, they were instructed to draw circles at a speed they considered comfortable; they then were instructed to draw circles at a speed they regarded as fast; afterwards, they repeated the comfortable task compelled to follow the rhythm of a metronome; and eventually they performed the fast task under the same timing constraints. Statistical differences between the tasks were computed, and while pen-tip normal force and total grip force signal were not impacted by the changes introduced in each task, writing quality features were affected by both the speed changes and timing constraint changes. This verifies the already-studied speed-accuracy trade-off and suggest the existence of a timing constraints-accuracy trade-off. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Subcortical Control of Precision Grip after Human Spinal Cord Injury

    PubMed Central

    Bunday, Karen L.; Tazoe, Toshiki; Rothwell, John C.

    2014-01-01

    The motor cortex and the corticospinal system contribute to the control of a precision grip between the thumb and index finger. The involvement of subcortical pathways during human precision grip remains unclear. Using noninvasive cortical and cervicomedullary stimulation, we examined motor evoked potentials (MEPs) and the activity in intracortical and subcortical pathways targeting an intrinsic hand muscle when grasping a small (6 mm) cylinder between the thumb and index finger and during index finger abduction in uninjured humans and in patients with subcortical damage due to incomplete cervical spinal cord injury (SCI). We demonstrate that cortical and cervicomedullary MEP size was reduced during precision grip compared with index finger abduction in uninjured humans, but was unchanged in SCI patients. Regardless of whether cortical and cervicomedullary stimulation was used, suppression of the MEP was only evident 1–3 ms after its onset. Long-term (∼5 years) use of the GABAb receptor agonist baclofen by SCI patients reduced MEP size during precision grip to similar levels as uninjured humans. Index finger sensory function correlated with MEP size during precision grip in SCI patients. Intracortical inhibition decreased during precision grip and spinal motoneuron excitability remained unchanged in all groups. Our results demonstrate that the control of precision grip in humans involves premotoneuronal subcortical mechanisms, likely disynaptic or polysynaptic spinal pathways that are lacking after SCI and restored by long-term use of baclofen. We propose that spinal GABAb-ergic interneuronal circuits, which are sensitive to baclofen, are part of the subcortical premotoneuronal network shaping corticospinal output during human precision grip. PMID:24849366

  12. Effects of object shape on the visual guidance of action.

    PubMed

    Eloka, Owino; Franz, Volker H

    2011-04-22

    Little is known of how visual coding of the shape of an object affects grasping movements. We addressed this issue by investigating the influence of shape perturbations on grasping. Twenty-six participants grasped a disc or a bar that were chosen such that they could in principle be grasped with identical movements (i.e., relevant sizes were identical such that the final grips consisted of identical separations of the fingers and no parts of the objects constituted obstacles for the movement). Nevertheless, participants took object shape into account and grasped the bar with a larger maximum grip aperture and a different hand angle than the disc. In 20% of the trials, the object changed its shape from bar to disc or vice versa early or late during the movement. If there was enough time (early perturbations), grasps were often adapted in flight to the new shape. These results show that the motor system takes into account even small and seemingly irrelevant changes of object shape and adapts the movement in a fine-grained manner. Although this adaptation might seem computationally expensive, we presume that its benefits (e.g., a more comfortable and more accurate movement) outweigh the costs. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Quantification of functional hand grip using electromyography and inertial sensor-derived accelerations: clinical implications.

    PubMed

    Martin-Martin, Jaime; Cuesta-Vargas, Antonio I

    2014-12-11

    Assessing hand injury is of great interest given the level of involvement of the hand with the environment. Knowing different assessment systems and their limitations generates new perspectives. The integration of digital systems (accelerometry and electromyography) as a tool to supplement functional assessment allows the clinician to know more about the motor component and its relation to movement. Therefore, the purpose of this study was the kinematic and electromyography analysis during functional hand movements. Ten subjects carried out six functional movements (terminal pinch, termino-lateral pinch, tripod pinch, power grip, extension grip and ball grip). Muscle activity (hand and forearm) was measured in real time using electromyograms, acquired with the Mega ME 6000, whilst acceleration was measured using the AcceleGlove. Electrical activity and acceleration variables were recorded simultaneously during the carrying out of the functional movements. The acceleration outcome variables were the modular vectors of each finger of the hand and the palm. In the electromyography, the main variables were normalized by the mean and by the maximum muscle activity of the thenar region, hypothenar, first interosseous dorsal, wrist flexors, carpal flexors and wrist extensors. Knowing muscle behavior allows the clinician to take a more direct approach in the treatment. Based on the results, the tripod grip shows greater kinetic activity and the middle finger is the most relevant in this regard. Ball grip involves most muscle activity, with the thenar region playing a fundamental role in hand activity. Relating muscle activation, movements, individual load and displacement offers the possibility to proceed with rehabilitation by individual component.

  14. Universal robotic gripper based on the jamming of granular material

    PubMed Central

    Brown, Eric; Rodenberg, Nicholas; Amend, John; Mozeika, Annan; Steltz, Erik; Zakin, Mitchell R.; Lipson, Hod; Jaeger, Heinrich M.

    2010-01-01

    Gripping and holding of objects are key tasks for robotic manipulators. The development of universal grippers able to pick up unfamiliar objects of widely varying shape and surface properties remains, however, challenging. Most current designs are based on the multifingered hand, but this approach introduces hardware and software complexities. These include large numbers of controllable joints, the need for force sensing if objects are to be handled securely without crushing them, and the computational overhead to decide how much stress each finger should apply and where. Here we demonstrate a completely different approach to a universal gripper. Individual fingers are replaced by a single mass of granular material that, when pressed onto a target object, flows around it and conforms to its shape. Upon application of a vacuum the granular material contracts and hardens quickly to pinch and hold the object without requiring sensory feedback. We find that volume changes of less than 0.5% suffice to grip objects reliably and hold them with forces exceeding many times their weight. We show that the operating principle is the ability of granular materials to transition between an unjammed, deformable state and a jammed state with solid-like rigidity. We delineate three separate mechanisms, friction, suction, and interlocking, that contribute to the gripping force. Using a simple model we relate each of them to the mechanical strength of the jammed state. This advance opens up new possibilities for the design of simple, yet highly adaptive systems that excel at fast gripping of complex objects.

  15. Planning of visually guided reach-to-grasp movements: inference from reaction time and contingent negative variation (CNV).

    PubMed

    Zaepffel, Manuel; Brochier, Thomas

    2012-01-01

    We performed electroencephalogram (EEG) recording in a precuing task to investigate the planning processes of reach-to-grasp movements in human. In this reaction time (RT) task, subjects had to reach, grasp, and pull an object as fast as possible after a visual GO signal. We manipulated two parameters: the hand shape for grasping (precision grip or side grip) and the force required to pull the object (high or low). Three seconds before the GO onset, a cue provided advance information about force, grip, both parameters, or no information at all. EEG data show that reach-to-grasp movements generate differences in the topographic distribution of the late Contingent Negative Variation (ICNV) amplitude between the 4 precuing conditions. Along with RT data, it confirms that two distinct functional networks are involved with different time courses in the planning of grip and force. Finally, we outline the composite nature of the lCNV that might reflect both high- and low-level planning processes. Copyright © 2011 Society for Psychophysiological Research.

  16. Apparatus for loading shape memory gripper mechanisms

    DOEpatents

    Lee, Abraham P.; Benett, William J.; Schumann, Daniel L.; Krulevitch, Peter A.; Fitch, Joseph P.

    2001-01-01

    A method and apparatus for loading deposit material, such as an embolic coil, into a shape memory polymer (SMP) gripping/release mechanism. The apparatus enables the application of uniform pressure to secure a grip by the SMP mechanism on the deposit material via differential pressure between, for example, vacuum within the SMP mechanism and hydrostatic water pressure on the exterior of the SMP mechanism. The SMP tubing material of the mechanism is heated to above the glass transformation temperature (Tg) while reshaping, and subsequently cooled to below Tg to freeze the shape. The heating and/or cooling may, for example, be provided by the same water applied for pressurization or the heating can be applied by optical fibers packaged to the SMP mechanism for directing a laser beam, for example, thereunto. At a point of use, the deposit material is released from the SMP mechanism by reheating the SMP material to above the temperature Tg whereby it returns to its initial shape. The reheating of the SM material may be carried out by injecting heated fluid (water) through an associated catheter or by optical fibers and an associated beam of laser light, for example.

  17. Method for loading shape memory polymer gripper mechanisms

    DOEpatents

    Lee, Abraham P.; Benett, William J.; Schumann, Daniel L.; Krulevitch, Peter A.; Fitch, Joseph P.

    2002-01-01

    A method and apparatus for loading deposit material, such as an embolic coil, into a shape memory polymer (SMP) gripping/release mechanism. The apparatus enables the application of uniform pressure to secure a grip by the SMP mechanism on the deposit material via differential pressure between, for example, vacuum within the SMP mechanism and hydrostatic water pressure on the exterior of the SMP mechanism. The SMP tubing material of the mechanism is heated to above the glass transformation temperature (Tg) while reshaping, and subsequently cooled to below Tg to freeze the shape. The heating and/or cooling may, for example, be provided by the same water applied for pressurization or the heating can be applied by optical fibers packaged to the SMP mechanism for directing a laser beam, for example, thereunto. At a point of use, the deposit material is released from the SMP mechanism by reheating the SMP material to above the temperature Tg whereby it returns to its initial shape. The reheating of the SMP material may be carried out by injecting heated fluid (water) through an associated catheter or by optical fibers and an associated beam of laser light, for example.

  18. Anticipatory planning and control of grasp positions and forces for dexterous two-digit manipulation.

    PubMed

    Fu, Qiushi; Zhang, Wei; Santello, Marco

    2010-07-07

    Dexterous object manipulation requires anticipatory control of digit positions and forces. Despite extensive studies on sensorimotor learning of digit forces, how humans learn to coordinate digit positions and forces has never been addressed. Furthermore, the functional role of anticipatory modulation of digit placement to object properties remains to be investigated. We addressed these questions by asking human subjects (12 females, 12 males) to grasp and lift an inverted T-shaped object using precision grip at constrained or self-chosen locations. The task requirement was to minimize object roll during lift. When digit position was not constrained, subjects could have implemented many equally valid digit position-force coordination patterns. However, choice of digit placement might also have resulted in large trial-to-trial variability of digit position, hence challenging the extent to which the CNS could have relied on sensorimotor memories for anticipatory control of digit forces. We hypothesized that subjects would modulate digit placement for optimal force distribution and digit forces as a function of variable digit positions. All subjects learned to minimize object roll within the first three trials, and the unconstrained device was associated with significantly smaller grip forces but larger variability of digit positions. Importantly, however, digit load force modulation compensated for position variability, thus ensuring consistent object roll minimization on each trial. This indicates that subjects learned object manipulation by integrating sensorimotor memories with sensory feedback about digit positions. These results are discussed in the context of motor equivalence and sensorimotor integration of grasp kinematics and kinetics.

  19. Application of Quality Function Deployment (QFD) method and kano model to redesign fresh fruit bunches sorting tool

    NASA Astrophysics Data System (ADS)

    Anizar; Siregar, I.; Yahya, I.; Yesika, N.

    2018-02-01

    The activity of lowering fresh fruit bunches (FFB) from truck to sorting floor is performed manually by workers using a sorting tool. Previously, the sorting tool used is a pointed iron bar with a T-shaped handle. Changes made to the sorting tool causes several complaints on worker and affect the time to lower the fruit. The purpose of this article is to obtain the design of an FFB sorting tool that suits the needs of these workers by applying the Quality Function Deployment (QFD) and Kano Model methods. Both of the two methods will be integrated to find the design that matches workers’ image and psychological feeling. The main parameters are to obtain the customer requirements of the palm fruit loading workers, to find the most important technical characteristics and critical part affecting the quality of the FFB sorting tool. The customer requirements of the palm loading workers are the following : the color of the coating paint is gray, the bar material is made of stainless pipe, the main grip coating material is made of grip, the tip material is made of the spring steel, the additional grip is made of rubber and the handle is of triangular shape.

  20. Fracture Strength of Single-Crystal Silicon Carbide Microspecimens at Room and Elevated Temperature

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.; Sharpe, William N., Jr.; Beheim, Glenn M.; Evans, Laura J.; Jadaan, Osama M.

    2007-01-01

    Three shapes of tensile specimens were tested--curved with a very low stress concentration factor and straight with either a circular hole or an elliptical hole. The nominal thickness was 125 micron with a net section 100 micron wide; the overall length of these microspecimens was 3.1 mm. They were fabricated by an improved version of deep reactive ion etching, which produced specimens with smooth sidewalls and cross-sections having a slightly trapezoidal shape that was exaggerated inside the holes. The novel test setup used a vertical load train extending into a resistance furnace. The specimens had wedge-shaped ends which fit into ceramic grips. The fixed grip was mounted on a ceramic post, and the movable grip was connected to a load cell and actuator outside the furnace with a ceramic-encased nichrome wire. The same arrangement was used for tests at 24 and at 1000 C. The strengths of the curved specimens for two batches of material (made with slightly different processes) were 0.66+/-0.12 GPa and 0.45+/-0.20 GPa respectively at 24 C with identical values at 1000 C. The fracture strengths of the circular-hole and elliptical-hole specimens (computed from the stress concentration factors and measured loads at failure) were approximately 1.2 GPa with slight decreases at the higher temperature. Fractographic examinations showed failures initiating on the surface--primarily at corners. Weibull predictions of fracture strengths for the hole specimens based on the properties of the curved specimens were reasonably effective for the circular holes, but not for the elliptical holes.

  1. Precision grip responses to unexpected rotational perturbations scale with axis of rotation.

    PubMed

    De Gregorio, Michael; Santos, Veronica J

    2013-04-05

    It has been established that rapid, pulse-like increases in precision grip forces ("catch-up responses") are elicited by unexpected translational perturbations and that response latency and strength scale according to the direction of linear slip relative to the hand as well as gravity. To determine if catch-up responses are elicited by unexpected rotational perturbations and are strength-, axis-, and/or direction-dependent, we imposed step torque loads about each of two axes which were defined relative to the subject's hand: the distal-proximal axis away from and towards the subject's palm, and the grip axis which connects the two fingertips. Precision grip responses were dominated initially by passive mechanics and then by active, unimodal catch-up responses. First dorsal interosseous activity, marking the start of the catch-up response, began 71-89 ms after the onset of perturbation. The onset latency, shape, and duration (217-231 ms) of the catch-up response were not affected by the axis, direction, or magnitude of the rotational perturbation, while strength was scaled by axis of rotation and slip conditions. Rotations about the grip axis that tilted the object away from the palm and induced rotational slip elicited stronger catch-up responses than rotations about the distal-proximal axis that twisted the object between the digits. To our knowledge, this study is the first to investigate grip responses to unexpected torque loads and to show characteristic, yet axis-dependent, catch-up responses for conditions other than pure linear slip. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. The effect of workstation and task variables on forces applied during simulated meat cutting.

    PubMed

    McGorry, Raymond W; Dempsey, Patrick G; O'Brien, Niall V

    2004-12-01

    The purpose of the study was to investigate factors related to force and postural exposure during a simulated meat cutting task. The hypothesis was that workstation, tool and task variables would affect the dependent kinetic variables of gripping force, cutting moment and the dependent kinematic variables of elbow elevation and wrist angular displacement in the flexion/extension and radial/ulnar deviation planes. To evaluate this hypothesis a 3 x 3 x 2 x 2 x 2 (surface orientation by surface height by blade angle by cut complexity by work pace) within-subject factorial design was conducted with 12 participants. The results indicated that the variables can act and interact to modify the kinematics and kinetics of a cutting task. Participants used greater grip force and cutting moment when working at a pace based on productivity. The interactions of the work surface height and orientation indicated that the use of an adjustable workstation could minimize wrist deviation from neutral and improve shoulder posture during cutting operations. Angling the knife blade also interacted with workstation variables to improve wrist and upper extremity posture, but this benefit must be weighed against the potential for small increases in force exposure.

  3. Microspine Gripping Mechanism for Asteroid Capture

    NASA Technical Reports Server (NTRS)

    Merriam, Ezekiel G.; Berg, Andrew B.; Willig, Andrew; Parness, Aaron; Frey, Tim; Howell, Larry L.

    2016-01-01

    This paper details the development and early testing of a compliant suspension for a microspine gripper device for asteroid capture or micro-gravity percussive drilling. The microspine gripper architecture is reviewed, and a proposed microspine suspension design is presented and discussed. Prototyping methods are discussed, as well as testing methods and results. A path forward is identified from the results of the testing completed thus far. Key findings include: the microspine concept has been established as a valid architecture and the compliant suspension exhibits the desired stiffness characteristics for good gripping behavior. These developments will aid in developing the capability to grasp irregularly shaped boulders in micro-gravity.

  4. Layered Plating Specimens For Mechanical Tests

    NASA Technical Reports Server (NTRS)

    Thompson, Linda B.; Flowers, Cecil E.

    1991-01-01

    Layered specimens readily made in standard sizes for tensile and other tests of mechanical properties. Standard specimen of metal ordinarily difficult to plate to standard grip thickness or diameter made by augmentation with easier-to-plate material followed by machining to standard size and shape.

  5. CONTROL FOR ROLLING MILL

    DOEpatents

    Shuck, A.B.; Shaw, W.C.

    1961-06-20

    A plutonium-rolling apparatus is patented that has two sets of feed rolls, shaping rolls between the feed rolls, and grippers beyond the feed rolls, which ready a workpiece for a new pass through the shaping rolls by angularly shifting the workpiece about its axis or transversely moving it on a line parallel to the axes of the shaping rolls. Actuation of each gripper for gripping or releasing the workpiece is produced by the relative positions assumed by the feed rolls adjacent to the gripper as the workpiece enters or leaves the feed rolls.

  6. Why pens have rubbery grips

    NASA Astrophysics Data System (ADS)

    Dzidek, Brygida; Bochereau, Séréna; Johnson, Simon A.; Hayward, Vincent; Adams, Michael J.

    2017-10-01

    The process by which human fingers gives rise to stable contacts with smooth, hard objects is surprisingly slow. Using high-resolution imaging, we found that, when pressed against glass, the actual contact made by finger pad ridges evolved over time following a first-order kinetics relationship. This evolution was the result of a two-stage coalescence process of microscopic junctions made between the keratin of the stratum corneum of the skin and the glass surface. This process was driven by the secretion of moisture from the sweat glands, since increased hydration in stratum corneum causes it to become softer. Saturation was typically reached within 20 s of loading the contact, regardless of the initial moisture state of the finger and of the normal force applied. Hence, the gross contact area, frequently used as a benchmark quantity in grip and perceptual studies, is a poor reflection of the actual contact mechanics that take place between human fingers and smooth, impermeable surfaces. In contrast, the formation of a steady-state contact area is almost instantaneous if the counter surface is soft relative to keratin in a dry state. It is for this reason that elastomers are commonly used to coat grip surfaces.

  7. Apparatus for tensile testing plate-type ceramic specimens

    DOEpatents

    Liu, Kenneth C.

    1993-01-01

    Apparatus for tensile testing plate-type ceramic specimens having dogbone- or T-shaped end sections without introducing bending stresses in the specimens during the application of a dynamic tensile loading on the specimens is described. A pair of elongated pull rods disposed in a side-by-side relationship are used to grip the shoulders on each T-shaped end section. The pull rods are pivotally attached to a piston-displaceable, disk-shaped member so as to be longitudinally movable with respect to one another effecting the self-alignment thereof with the shoulders on the T-shaped end sections of the specimen to compensate for shoulders being located in different longitudinal positions.

  8. Role of stag beetle jaw bending and torsion in grip on rivals.

    PubMed

    Goyens, Jana; Dirckx, Joris; Piessen, Maxim; Aerts, Peter

    2016-01-01

    In aggressive battles, the extremely large male stag beetle jaws have to withstand strongly elevated bite forces. We found several adaptations of the male Cyclommatus metallifer jaw morphology for enhanced robustness that conspecific females lack. As a result, males improve their grip on opponents and they maintain their safety factor (5.2-7.2) at the same level as that of females (6.8), despite their strongly elevated bite muscle force (3.9 times stronger). Males have a higher second moment of area and torsion constant than females, owing to an enhanced cross-sectional area and shape. These parameters also increase faster with increasing bending moment towards the jaw base in males than in females. Male jaws are more bending resistant against the bite reaction force than against perpendicular forces (which remain lower in battles). Because of the triangular cross section of the male jaw base, it twists more easily than it bends. This torsional flexibility creates a safety system against overload that, at the same time, secures a firm grip on rivals. We found no structural mechanical function of the large teeth halfway along the male jaws. Therefore, it appears that the main purpose of these teeth is a further improvement of grip on rivals. © 2016 The Author(s).

  9. Role of stag beetle jaw bending and torsion in grip on rivals

    PubMed Central

    Goyens, Jana; Dirckx, Joris; Piessen, Maxim; Aerts, Peter

    2016-01-01

    In aggressive battles, the extremely large male stag beetle jaws have to withstand strongly elevated bite forces. We found several adaptations of the male Cyclommatus metallifer jaw morphology for enhanced robustness that conspecific females lack. As a result, males improve their grip on opponents and they maintain their safety factor (5.2–7.2) at the same level as that of females (6.8), despite their strongly elevated bite muscle force (3.9 times stronger). Males have a higher second moment of area and torsion constant than females, owing to an enhanced cross-sectional area and shape. These parameters also increase faster with increasing bending moment towards the jaw base in males than in females. Male jaws are more bending resistant against the bite reaction force than against perpendicular forces (which remain lower in battles). Because of the triangular cross section of the male jaw base, it twists more easily than it bends. This torsional flexibility creates a safety system against overload that, at the same time, secures a firm grip on rivals. We found no structural mechanical function of the large teeth halfway along the male jaws. Therefore, it appears that the main purpose of these teeth is a further improvement of grip on rivals. PMID:26763329

  10. Apparatus for adapting an end effector device remotely controlled manipulator arm

    NASA Technical Reports Server (NTRS)

    Clark, K. H. (Inventor)

    1985-01-01

    Apparatus for adapting a general purpose and effector device to a special purpose and effector is disclosed which includes an adapter bracket assembly which provides a mechanical and electrical interface between the end effector devices. The adapter bracket assembly includes an adapter connector post which interlocks with a diamond shaped gripping channel formed in closed jaws of the general purpose end effector. The angularly intersecting surfaces of the connector post and gripping channel prevent any relative movement there between. Containment webs constrain the outer finger plates of the general purpose jaws to prevent pitch motion. Electrical interface is provided by conical, self aligning electrical connector components carried by respective ones of said end effectors.

  11. Reliability and validity of the closed kinetic chain upper extremity stability test.

    PubMed

    Lee, Dong-Rour; Kim, Laurentius Jongsoon

    2015-04-01

    [Purpose] The purpose of this study was to examine the reliability and validity of the Closed Kinetic Chain Upper Extremity Stability (CKCUES) test. [Subjects and Methods] A sample of 40 subjects (20 males, 20 females) with and without pain in the upper limbs was recruited. The subjects were tested twice, three days apart to assess the reliability of the CKCUES test. The CKCUES test was performed four times, and the average was calculated using the data of the last 3 tests. In order to test the validity of the CKCUES test, peak torque of internal/external shoulder rotation was measured using an isokinetic dynamometer, and maximum grip strength was measured using a hand dynamometer, and their Pearson correlation coefficients with the average values of the CKCUES test were calculated. [Results] The reliability of the CKCUES test was very high (ICC=0.97). The correlations between the CKCUES test and maximum grip strength (r=0.78-0.79), and the peak torque of internal/external shoulder rotation (r=0.87-0.94) were high indicating its validity. [Conclusion] The reliability and validity of the CKCUES test were high. The CKCUES test is expected to be used for clinical tests on upper limb stability at low price.

  12. Controllable load sharing for soft adhesive interfaces on three-dimensional surfaces.

    PubMed

    Song, Sukho; Drotlef, Dirk-Michael; Majidi, Carmel; Sitti, Metin

    2017-05-30

    For adhering to three-dimensional (3D) surfaces or objects, current adhesion systems are limited by a fundamental trade-off between 3D surface conformability and high adhesion strength. This limitation arises from the need for a soft, mechanically compliant interface, which enables conformability to nonflat and irregularly shaped surfaces but significantly reduces the interfacial fracture strength. In this work, we overcome this trade-off with an adhesion-based soft-gripping system that exhibits enhanced fracture strength without sacrificing conformability to nonplanar 3D surfaces. Composed of a gecko-inspired elastomeric microfibrillar adhesive membrane supported by a pressure-controlled deformable gripper body, the proposed soft-gripping system controls the bonding strength by changing its internal pressure and exploiting the mechanics of interfacial equal load sharing. The soft adhesion system can use up to ∼26% of the maximum adhesion of the fibrillar membrane, which is 14× higher than the adhering membrane without load sharing. Our proposed load-sharing method suggests a paradigm for soft adhesion-based gripping and transfer-printing systems that achieves area scaling similar to that of a natural gecko footpad.

  13. Controllable load sharing for soft adhesive interfaces on three-dimensional surfaces

    NASA Astrophysics Data System (ADS)

    Song, Sukho; Drotlef, Dirk-Michael; Majidi, Carmel; Sitti, Metin

    2017-05-01

    For adhering to three-dimensional (3D) surfaces or objects, current adhesion systems are limited by a fundamental trade-off between 3D surface conformability and high adhesion strength. This limitation arises from the need for a soft, mechanically compliant interface, which enables conformability to nonflat and irregularly shaped surfaces but significantly reduces the interfacial fracture strength. In this work, we overcome this trade-off with an adhesion-based soft-gripping system that exhibits enhanced fracture strength without sacrificing conformability to nonplanar 3D surfaces. Composed of a gecko-inspired elastomeric microfibrillar adhesive membrane supported by a pressure-controlled deformable gripper body, the proposed soft-gripping system controls the bonding strength by changing its internal pressure and exploiting the mechanics of interfacial equal load sharing. The soft adhesion system can use up to ˜26% of the maximum adhesion of the fibrillar membrane, which is 14× higher than the adhering membrane without load sharing. Our proposed load-sharing method suggests a paradigm for soft adhesion-based gripping and transfer-printing systems that achieves area scaling similar to that of a natural gecko footpad.

  14. Hand-handle interface force and torque measurement system for pneumatic assembly tool operations: suggested enhancement to ISO 6544.

    PubMed

    Lin, Jia-Hua; McGorry, Raymond W; Chang, Chien-Chi

    2007-05-01

    A hand-handle interface force and torque measurement system is introduced to fill the void acknowledged in the international standard ISO 6544, which governs pneumatic, assembly tool reaction torque and force measurement. This system consists of an instrumented handle with a sensor capable of measuring grip force and reaction hand moment when threaded, fastener-driving tools are used by operators. The handle is rigidly affixed to the tool in parallel to the original tool handle allowing normal fastener-driving operations with minimal interference. Demonstration of this proposed system was made with tools of three different shapes: pistol grip, right angle, and in-line. During tool torque buildup, the proposed system measured operators exerting greater grip force on the soft joint than on the hard joint. The system also demonstrated that the soft joint demanded greater hand moment impulse than the hard joint. The results demonstrate that the measurement system can provide supplemental data useful in exposure assessment with power hand tools as proposed in ISO 6544.

  15. Controllable load sharing for soft adhesive interfaces on three-dimensional surfaces

    PubMed Central

    Song, Sukho; Drotlef, Dirk-Michael; Majidi, Carmel; Sitti, Metin

    2017-01-01

    For adhering to three-dimensional (3D) surfaces or objects, current adhesion systems are limited by a fundamental trade-off between 3D surface conformability and high adhesion strength. This limitation arises from the need for a soft, mechanically compliant interface, which enables conformability to nonflat and irregularly shaped surfaces but significantly reduces the interfacial fracture strength. In this work, we overcome this trade-off with an adhesion-based soft-gripping system that exhibits enhanced fracture strength without sacrificing conformability to nonplanar 3D surfaces. Composed of a gecko-inspired elastomeric microfibrillar adhesive membrane supported by a pressure-controlled deformable gripper body, the proposed soft-gripping system controls the bonding strength by changing its internal pressure and exploiting the mechanics of interfacial equal load sharing. The soft adhesion system can use up to ∼26% of the maximum adhesion of the fibrillar membrane, which is 14× higher than the adhering membrane without load sharing. Our proposed load-sharing method suggests a paradigm for soft adhesion-based gripping and transfer-printing systems that achieves area scaling similar to that of a natural gecko footpad. PMID:28507143

  16. Study on functional relationships between ergonomics indexes of manual performance

    NASA Astrophysics Data System (ADS)

    Hu, Hui-Min; Ding, Li; Chen, Shou-Ping; Yang, Chun-Xin; Yuan, Xiu-Gan

    This paper investigates functional relationships between some of the key ergonomics indexes in manual performance, and attempts to condense the ergonomics appraisal indexes system and thus evaluate hand performance wearing EVA (extravehicular activity) glove, design and improve EVA glove's performance. Four types of ergonomics indexes were studied, i.e., dexterity, tactile sensibility (TS), strength and fatigue. Two test items of insert sticks into a holes-board (ISIHB) and nuts-bolts assembly task (NBAT) were used to measure dexterity, while shape discrimination (SD) was employed for TS, and grip force (GF) for strength and fatigue. The variables measured in this investigation included accomplishing time (AT) of ISIHB and NBAT, correct rate (CR) of SD, maximal grip force (MGF), instant grip force (IGF) and endurance time of grip force (ETGF). Experiments were conducted on 31 undergraduates (eight female and 23 male) with two experiment conditions of bare-hand group and gloved hand group. Results demonstrated that dexterity and TS performance of gloved hand group declined significantly compared with those of bare-hand group (p<0.001). There were not significant differences in strength and fatigue between two conditions (p>0.05). Four effective functional relationships were developed between four pairs of ergonomics indexes in bare-hand group. In gloved hand group, in addition to above-mentioned four pairs of relationships, another formula was found, which was y^=0.02061+0.01233x ( p<0.01, dexterity and TS).

  17. The c.429_452 duplication of the ARX gene: a unique developmental-model of limb kinetic apraxia.

    PubMed

    Curie, Aurore; Nazir, Tatjana; Brun, Amandine; Paulignan, Yves; Reboul, Anne; Delange, Karine; Cheylus, Anne; Bertrand, Sophie; Rochefort, Fanny; Bussy, Gérald; Marignier, Stéphanie; Lacombe, Didier; Chiron, Catherine; Cossée, Mireille; Leheup, Bruno; Philippe, Christophe; Laugel, Vincent; De Saint Martin, Anne; Sacco, Silvia; Poirier, Karine; Bienvenu, Thierry; Souville, Isabelle; Gilbert-Dussardier, Brigitte; Bieth, Eric; Kauffmann, Didier; Briot, Philippe; de Fréminville, Bénédicte; Prieur, Fabienne; Till, Michel; Rooryck-Thambo, Caroline; Mortemousque, Isabelle; Bobillier-Chaumont, Isabelle; Toutain, Annick; Touraine, Renaud; Sanlaville, Damien; Chelly, Jamel; Freeman, Sonya; Kong, Jian; Hadjikhani, Nouchine; Gollub, Randy L; Roy, Alice; des Portes, Vincent

    2014-02-14

    The c.429_452dup24 of the ARX gene is a rare genetic anomaly, leading to X-Linked Intellectual Disability without brain malformation. While in certain cases c.429_452dup24 has been associated with specific clinical patterns such as Partington syndrome, the consequence of this mutation has been also often classified as "non-specific Intellectual Disability". The present work aims at a more precise description of the clinical features linked to the c.429_452dup24 mutation. We clinically reviewed all affected patients identified in France over a five-year period, i.e. 27 patients from 12 different families. Detailed cognitive, behavioural, and motor evaluation, as well as standardized videotaped assessments of oro-lingual and gestural praxis, were performed. In a sub-group of 13 ARX patients, kinematic and MRI studies were further accomplished to better characterize the motor impairment prevalent in the ARX patients group. To ensure that data were specific to the ARX gene mutation and did not result from low-cognitive functioning per se, a group of 27 age- and IQ-matched Down syndrome patients served as control. Neuropsychological and motor assessment indicated that the c.429_452dup24 mutation constitutes a recognizable clinical syndrome: ARX patients exhibiting Intellectual Disability, without primary motor impairment, but with a very specific upper limb distal motor apraxia associated with a pathognomonic hand-grip. Patients affected with the so-called Partington syndrome, which involves major hand dystonia and orolingual apraxia, exhibit the most severe symptoms of the disorder. The particular "reach and grip" impairment which was observed in all ARX patients, but not in Down syndrome patients, was further characterized by the kinematic data: (i) loss of preference for the index finger when gripping an object, (ii) major impairment of fourth finger deftness, and (iii) a lack of pronation movements. This lack of distal movement coordination exhibited by ARX patients is associated with the loss of independent digital dexterity and is similar to the distortion of individual finger movements and posture observed in Limb Kinetic Apraxia. These findings suggest that the ARX c.429_452dup24 mutation may be a developmental model for Limb Kinetic Apraxia.

  18. Transfer of adaptation reveals shared mechanism in grasping and manual estimation.

    PubMed

    Cesanek, Evan; Domini, Fulvio

    2018-06-19

    An influential idea in cognitive neuroscience is that perception and action are highly separable brain functions, implemented in distinct neural systems. In particular, this theory predicts that the functional distinction between grasping, a skilled action, and manual estimation, a type of perceptual report, should be mirrored by a split between their respective control systems. This idea has received support from a variety of dissociations, yet many of these findings have been criticized for failing to pinpoint the source of the dissociation. In this study, we devised a novel approach to this question, first targeting specific grasp control mechanisms through visuomotor adaptation, then testing whether adapted mechanisms were also involved in manual estimation - a response widely characterized as perceptual in function. Participants grasped objects in virtual reality that could appear larger or smaller than the actual physical sizes felt at the end of each grasp. After brief exposure to a size perturbation, manual estimates were biased in the same direction as the maximum grip apertures of grasping movements, indicating that the adapted mechanism is active in both tasks, regardless of the perception-action distinction. Additional experiments showed that the transfer effect generalizes broadly over space (Exp. 1B) and does not appear to arise from a change in visual perception (Exp. 2). We discuss two adaptable mechanisms that could have mediated the observed effect: (a) an afferent proprioceptive mechanism for sensing grip shape; and (b) an efferent visuomotor transformation of size information into a grip-shaping motor command. Copyright © 2018. Published by Elsevier Ltd.

  19. Finger pad friction and its role in grip and touch

    PubMed Central

    Adams, Michael J.; Johnson, Simon A.; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-01-01

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick–slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function. PMID:23256185

  20. Reattachment of the greater trochanter using the Dall-Miles cable grip system in revision hip arthroplasty.

    PubMed

    Koyama, K; Higuchi, F; Kubo, M; Okawa, T; Inoue, A

    2001-01-01

    Clinical and radiographic results of trochanteric osteotomy after revision hip arthroplasty in 62 hips were reviewed. The osteotomized fragment had been reattached using the Dall-Miles cable grip system in each hip. The patients' average age at operation was 64.4 years (range, 40-86 years). The average duration of follow-up was 30.0 months (range. 12-60 months). Trochanteric nonunion was found in 19 hips (30.6%). Trochanteric nonunion developed in 14 (38.9%) of 36 hips with each cable attached around the medial cortex bone, in 2 (16.7%) of 12 hips with each cable passed in a drill hole, and in 3 (21.4%) of 14 hips with one cable passed through a hole and the other attached around the medial cortex. Fragmentation developed in 18 hips (29.0%). In 3 of these 18, the fragments had migrated close to the acetabular component. Cable breakage was seen in 4 hips (6.5%), and bone absorption around the cable in the medial cortex was seen in 17 hips (27.4%). There were 16 hips (25.8%) that presented symptoms at the greater trochanter, including spontaneous pain and tenderness. When the Dall Miles cable grip device is used for reattachment of the greater trochanter, attention should be paid to the condition of the trochanteric bed, the tension of the abductor muscles, and to the placement of the cables and the H-shaped grip.

  1. Evaluation of pliers' grip spans in the maximum gripping task and sub-maximum cutting task.

    PubMed

    Kim, Dae-Min; Kong, Yong-Ku

    2016-12-01

    A total of 25 males participated to investigate the effects of the grip spans of pliers on the total grip force, individual finger forces and muscle activities in the maximum gripping task and wire-cutting tasks. In the maximum gripping task, results showed that the 50-mm grip span had significantly higher total grip strength than the other grip spans. In the cutting task, the 50-mm grip span also showed significantly higher grip strength than the 65-mm and 80-mm grip spans, whereas the muscle activities showed a higher value at 80-mm grip span. The ratios of cutting force to maximum grip strength were also investigated. Ratios of 30.3%, 31.3% and 41.3% were obtained by grip spans of 50-mm, 65-mm, and 80-mm, respectively. Thus, the 50-mm grip span for pliers might be recommended to provide maximum exertion in gripping tasks, as well as lower maximum-cutting force ratios in the cutting tasks.

  2. Gripping Mechanisms for Microgravity and Extreme Terrain and Vertical Climbing Micro Ground Vehicle

    NASA Technical Reports Server (NTRS)

    McKenzie, Clifford; Parness, Aaron

    2011-01-01

    Asteroids and comets may provide insight into the origins of our solar system and the precursors to life on our planet. Near Earth objects offer an accessible target of opportunity, but are small and lack the gravity necessary for conventional wheeled travel. Therefore, it is necessary to develop alternative methods for maneuvering in these environments. This project researched and developed a method for gripping rock surfaces. Work has been completed on the design and prototyping of several possible hooked gripping mechanisms. Future work includes quantitative testing, downselection to a final design, and attachment to the robotic platform, Lemur IIb. A second project focuses on the development of a 100g, crash-proof robot capable of climbing vertical surfaces using a novel silicone adhesive. Capable of carrying video/audio payloads the robot may serve as a surveillance tool for the Department of Defense or as a method of pre-flight spacecraft inspections. A specialized track was developed to provide the specific loading conditions necessary for proper engagement of the adhesive. Both of these projects rely heavily on the shape deposition manufacturing process, being researched at JPL, and 3D printing.

  3. Grip force regulation during pinch grip lifts under somatosensory guidance: comparison between people with stroke and healthy controls.

    PubMed

    Blennerhassett, Jannette M; Carey, Leeanne M; Matyas, Thomas A

    2006-03-01

    To compare the timing and grip force application in a pinch grip task performed under somatosensory guidance in stroke and matched controls and to identify characteristics of impaired grip force regulation after stroke. Matched-pairs control group. University research laboratory. Forty-five people with stroke who could pick up a pen lid using a pinch grip and actively participated in rehabilitation and 45 adults without neurologic conditions or musculoskeletal or skin impairments affecting the hand, matched for age, sex, and hand dominance. Not applicable. Timing and magnitude of grip forces applied during pinch grip lift and hold. Prolonged time to grip and lift objects, and excessive grip force prior to commencing the lift occurred in approximately half of the contralesional (involved) hands of people with stroke. Fluctuating irregular forces and reduced adaptation of the grip safety margin were also observed. Excessive safety margins were not predominant after stroke. Extreme slowing and disorganized sequencing of the grip and lifting forces and difficulty maintaining a stable grip characterized severe dysfunction. Delayed grip formulation and variable grip force application are key characteristics of grip dysfunction after stroke.

  4. The responsiveness of sensibility and strength tests in patients undergoing carpal tunnel decompression

    PubMed Central

    2011-01-01

    Background Several clinical measures of sensory and motor function are used alongside patient-rated questionnaires to assess outcomes of carpal tunnel decompression. However there is a lack of evidence regarding which clinical tests are most responsive to clinically important change over time. Methods In a prospective cohort study 63 patients undergoing carpal tunnel decompression were assessed using standardised clinician-derived and patient reported outcomes before surgery, at 4 and 8 months follow up. Clinical sensory assessments included: touch threshold with monofilaments (WEST), shape-texture identification (STI™ test), static two-point discrimination (Mackinnon-Dellon Disk-Criminator) and the locognosia test. Motor assessments included: grip and tripod pinch strength using a digital grip analyser (MIE), manual muscle testing of abductor pollicis brevis and opponens pollicis using the Rotterdam Intrinsic Handheld Myometer (RIHM). The Boston Carpal Tunnel Questionnaire (BCTQ) was used as a patient rated outcome measure. Results Relative responsiveness at 4 months was highest for the BCTQ symptom severity scale with moderate to large effects sizes (ES = -1.43) followed by the BCTQ function scale (ES = -0.71). The WEST and STI™ were the most responsive sensory tests at 4 months showing moderate effect sizes (WEST ES = 0.55, STI ES = 0.52). Grip and pinch strength had a relatively higher responsiveness compared to thenar muscle strength but effect sizes for all motor tests were very small (ES ≤0.10) or negative indicating a decline compared to baseline in some patients. Conclusions For clinical assessment of sensibility touch threshold assessed by monofilaments (WEST) and tactile gnosis measured with the STI™ test are the most responsive tests and are recommended for future studies. The use of handheld myometry (RIHM) for manual muscle testing, despite more specifically targeting thenar muscles, was less responsive than grip or tripod pinch testing using the digital grip analyser (MIE). When assessing power and pinch strength the effect of other concomitant conditions such as degenerative joint disease on strength needs to be considered. PMID:22032626

  5. Tensile testing grips ensure uniform loading of bimetal tubing specimens

    NASA Technical Reports Server (NTRS)

    Driscol, S. D.; Hunt, V.

    1968-01-01

    Tensile testing grip uniformly distributes stresses to the internal and external tube of bimetal tubing specimens. The grip is comprised of a slotted external tube grip, a slotted internal tube grip, a machine bolt and nut, an internal grip expansion cone, and an external grip compression nut.

  6. Bi-stem gripping apparatus

    NASA Technical Reports Server (NTRS)

    Sanders, Fred G. (Inventor)

    1988-01-01

    This invention relates to devices which grip cylindrical structures and more particularly to a device which has three arcuate gripping members having frictional surfaces for gripping and compressing a bi-stem. The bi-stem gripping apparatus is constructed having a pair of side gripping members, and an intermediate gripping member disposed between them. Sheets of a gum stock silicone rubber with frictional gripping surfaces are bonded to the inner region of the gripping members and provide frictional engagement between the bi-stem and the apparatus. A latch secures the gripping apparatus to a bi-stem, and removable handles are attached, allowing an astronaut to pull the bi-stem from its cassette. A tethering ring on the outside of the gripping apparatus provides a convenient point to which a lanyard may be attached.

  7. Easy-To-Use Connector-Assembly Tool

    NASA Technical Reports Server (NTRS)

    Redmon, John W., Jr.; Jankowski, Fred

    1988-01-01

    Tool compensates for user's loss of dexterity under awkward conditions. Has jaws that swivel over 180 degree so angle adjusts with respect to handles. Oriented and held in position most comfortable and effective for user in given situation. Jaws lined with rubber pads so they conform to irregularly shaped parts and grips firmly but gently. Once tool engages part, it locks on it so user can release handles without losing part. Ratchet mechanism in tool allows user to work handles back and forth in confined space to connect or disconnect part. Quickly positioned, locked, and released. Gives user feel of its grip on part. Frees grasping muscles from work during part of task, giving user greater freedom to move hand. Operates with only one hand, leaving user's other hand free to manipulate wiring or other parts. Also adapts to handling and positioning extremely-hot or extremely-cold fluid lines, contaminated objects, abrasive or sharp objects, fragile items, and soft objects.

  8. Reference Values of Grip Strength, Prevalence of Low Grip Strength, and Factors Affecting Grip Strength Values in Chinese Adults.

    PubMed

    Yu, Ruby; Ong, Sherlin; Cheung, Osbert; Leung, Jason; Woo, Jean

    2017-06-01

    The objectives of this study were to update the reference values of grip strength, to estimate the prevalence of low grip strength, and to examine the impact of different aspects of measurement protocol on grip strength values in Chinese adults. A cross-sectional survey of Chinese men (n = 714) and women (n = 4014) aged 18-102 years was undertaken in different community settings in Hong Kong. Grip strength was measured with a digital dynamometer (TKK 5401 Grip-D; Takei, Niigata, Japan). Low grip strength was defined as grip strength 2 standard deviations or more below the mean for young adults. The effects of measurement protocol on grip strength values were examined in a subsample of 45 men and women with repeated measures of grip strength taken with a hydraulic dynamometer (Baseline; Fabrication Enterprises Inc, Irvington, NY), using pair t-tests, intraclass correlation coefficient, and Bland and Altman plots. Grip strength was greater among men than among women (P < .001) and the rate of decline differed between sexes (P < .001). The prevalence of low grip strength also increased with age, reaching a rate of 16.5% in men and 20.6% in women aged 65+. Although the TKK digital dynamometer gave higher grip strength values than the Baseline hydraulic dynamometer (P < .001), the degree of agreement between the 2 dynamometers was satisfactory. Higher grip strength values were also observed when the measurement was performed with the elbow extended in a standing position, compared with that with the elbow flexed at 90° in a sitting position, using the same dynamometer (P < .05). This study updated the reference values of grip strength and estimated the prevalence of low grip strength among Chinese adults spanning a wide age range. These findings might be useful for risk estimation and evaluation of interventions. However, grip strength measurements should be interpreted with caution, as grip strength values can be affected by type of dynamometer used, assessment posture, and elbow position. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  9. Flexible Electrostatic Technologies for Capture and Handling, Phase 1

    NASA Technical Reports Server (NTRS)

    Bryan, Thomas

    2015-01-01

    Fundamental to many of NASA's in-space transportation missions is the capture and handling of various objects and vehicles in various orbits for servicing, debris disposal, sample retrieval, and assembly without the benefit of sufficient grapple fixtures and docking ports. To perform similar material handling tasks on Earth, pincher grippers, suction grippers, or magnetic chucks are used, but are unable to reliably grip aluminum and composite spacecraft, insulation, radiators, solar arrays, or extra-terrestrial objects in the vacuum of outer space without dedicated handles in the right places. The electronic Flexible Electrostatic Technologies for space Capture and Handling (FETCH) will enable reliable and compliant gripping (soft dock) of practically any object in various orbits or surfaces without dedicated mechanical features, very low impact capture, and built-in proximity sensing without any conventional actuators. Originally developed to handle semiconductor and glass wafers during vacuum chamber processing without contamination, the normal rigid wafer handling chucks are replaced with thin metal foil segments laminated in flexible insulation driven by commercial off-the-shelf solid state, high-voltage power supplies. Preliminary testing in NASA Marshall Space Flight Center's (MSFC's) Flat Floor Robotics Lab demonstrated compliant alignment and gripping with a full-sized, 150-lb microsat mockup and translation before a clean release with a flip of a switch. The flexible electrostatic gripper pads can be adapted to various space applications with different sizes, shapes, and foil electrode layouts even with openings through the gripper pads for addition of guidance sensors or injection of permanent adhesives. With gripping forces estimated between 0.5 and 2.5 lb/in2 or 70-300 lb/ft2 of surface contact, the FETCH can turn on and off rapidly and repeatedly to enable sample handling, soft docking, in-space assembly, precision relocation, and surface translation for accurate anchoring.

  10. Force related hemodynamic responses during execution and imagery of a hand grip task: A functional near infrared spectroscopy study.

    PubMed

    Wriessnegger, Selina C; Kirchmeyr, Daniela; Bauernfeind, Günther; Müller-Putz, Gernot R

    2017-10-01

    We examined force related hemodynamic changes during the performance of a motor execution (ME) and motor imagery (MI) task by means of multichannel functional near infrared spectroscopy (fNIRS). The hemodynamic responses of fourteen healthy participants were measured while they performed a hand grip execution or imagery task with low and high grip forces. We found an overall higher increase of [oxy-Hb] concentration changes during ME for both grip forces but with a delayed peak maximum for the lower grip force. During the MI task with lower grip force, the [oxy-Hb] level increases are stronger compared to the MI with higher grip force. The facilitation in performing MI with higher grip strength might thus indicate less inhibition of the actual motor act which could also explain the later increase onset of [oxy-Hb] in the ME task with the lower grip force. Our results suggest that execution and imagery of a hand grip task with high and low grip forces, leads to different cortical activation patterns. Since impaired control of grip forces during object manipulation in particular is one aspect of fine motor control deficits after stroke, our study will contribute to future rehabilitation programs enhancing patient's grip force control. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Apparatus for tensile testing plate-type ceramic specimens

    DOEpatents

    Liu, K.C.

    1993-08-24

    Apparatus is described for gripping a plate-type tensile specimen having generally T-shaped end regions in a dynamic tension fatigue testing apparatus comprising an annular housing having an open-ended elongated cavity therein, a plurality of hydraulic piston means supported by the housing in a spaced array about the cavity, and a specimen-supporting plate means overlying the piston means at one end of the elongated cavity and displaceable by said piston means in a longitudinal direction with respect to the longitudinal axis of the cavity, said apparatus for gripping a flat plate-type tensile specimen comprising: a pair of elongated pull rods each having oppositely disposed first and second end regions; a pair of mounting means carried by said plate means with each mounting means for pivotally attaching the first end region of each of said pull rods in a central region of said plate means for supporting said pair of elongated pull rods in a side-by-side relationship along a common longitudinal centerline within said cavity; recess means in the second end region of each of said pull rods in adjacently disposed surface regions thereof with said recess means facing one another and each adapted to receive one side of one of the generally T-shaped end regions of the plate-type tensile specimen; and load-bearing means positionable in each of said recess means and adapted to bear against a shoulder on each side of the generally T-shaped end region of the plate-type tensile specimen when a tensile loading is applied thereon.

  12. Why arboreal snakes should not be cylindrical: body shape, incline and surface roughness have interactive effects on locomotion.

    PubMed

    Jayne, Bruce C; Newman, Steven J; Zentkovich, Michele M; Berns, H Matthew

    2015-12-01

    Depending on animal size, shape, body plan and behaviour, variation in surface structure can affect the speed and ease of locomotion. The slope of branches and the roughness of bark both vary considerably, but their combined effects on the locomotion of arboreal animals are poorly understood. We used artificial branches with five inclines and five peg heights (≤40 mm) to test for interactive effects on the locomotion of three snake species with different body shapes. Unlike boa constrictors (Boa constrictor), corn snakes (Pantherophis guttatus) and brown tree snakes (Boiga irregularis) can both form ventrolateral keels, which are most pronounced in B. irregularis. Increasing peg height up to 10 mm elicited more of the lateral undulatory behaviour (sliding contact without gripping) rather than the concertina behaviour (periodic static gripping) and increased the speed of lateral undulation. Increased incline: (1) elicited more concertina locomotion, (2) decreased speed and (3) increased the threshold peg height that elicited lateral undulation. Boiga irregularis was the fastest species, and it used lateral undulation on the most surfaces, including a vertical cylinder with pegs only 1 mm high. Overall, B. constrictor was the slowest and used the most concertina locomotion, but this species climbed steep, smooth surfaces faster than P. guttatus. Our results illustrate how morphology and two different aspects of habitat structure can have interactive effects on organismal performance and behaviour. Notably, a sharper keel facilitated exploiting shorter protrusions to prevent slipping and provide propulsion, which became increasingly important as surface steepness increased. © 2015. Published by The Company of Biologists Ltd.

  13. Predicting kinetic nanocrystal shapes through multi-scale theory and simulation: Polyvinylpyrrolidone-mediated growth of Ag nanocrystals

    NASA Astrophysics Data System (ADS)

    Balankura, Tonnam; Qi, Xin; Zhou, Ya; Fichthorn, Kristen A.

    2016-10-01

    In the shape-controlled synthesis of colloidal Ag nanocrystals, structure-directing agents, particularly polyvinylpyrrolidone (PVP), are known to be a key additive in making nanostructures with well-defined shapes. Although many Ag nanocrystals have been successfully synthesized using PVP, the mechanism by which PVP actuates shape control remains elusive. Here, we present a multi-scale theoretical framework for kinetic Wulff shape predictions that accounts for the chemical environment, which we used to probe the kinetic influence of the adsorbed PVP film. Within this framework, we use umbrella-sampling molecular dynamics simulations to calculate the potential of mean force and diffusion coefficient profiles of Ag atom deposition onto Ag(100) and Ag(111) in ethylene glycol solution with surface-adsorbed PVP. We use these profiles to calculate the mean-first passage times and implement extensive Brownian dynamics simulations, which allows the kinetic effects to be quantitatively evaluated. Our results show that PVP films can regulate the flux of Ag atoms to be greater towards Ag(111) than Ag(100). PVP's preferential binding towards Ag(100) over Ag(111) gives PVP its flux-regulating capabilities through the lower free-energy barrier of Ag atoms to cross the lower-density PVP film on Ag(111) and enhanced Ag trapping by the extended PVP film on Ag(111). Under kinetic control, {100}-faceted nanocrystals will be formed when the Ag flux is greater towards Ag(111). The predicted kinetic Wulff shapes are in agreement with the analogous experimental system.

  14. An instrumented object for hand exercise and assessment using a pneumatic pressure sensor

    NASA Astrophysics Data System (ADS)

    Mohan, A.; Tharion, G.; Kumar, R. K.; Devasahayam, S. R.

    2018-05-01

    Measurement of grip force is important for both exercise training and assessment of the hand during physical rehabilitation. The standard method uses a grip dynamometer which measures the force between the fingers and opposing thumb. The primary limitation of the grip dynamometer is the restriction of measurement to cylindrical grasps. Any deformation of the hand due to muscular or skeletal disease makes the grip dynamometer difficult or impossible to use. An alternative to the grip dynamometer is a sealed pneumatic object that can be gripped by the hand. Measurement of the internal pressure in the object can be related to the grip force. In this paper, we analyze such a pneumatic pressure sensing object for hand grip assessment and also describe an easy fabrication of the grip sensor. The instrumented object presented in this paper is designed to assess both the maximal voluntary grip forces and continuous grip force to monitor control of hand function during exercise under instruction from a therapist. Potential uses of such a pneumatic pressure sensing object for hand grip are in physical rehabilitation of patients following paralysing illnesses like stroke and spinal cord injury.

  15. Pistol-grip Syringe holder (Cameco syringe pistol) in fine needle aspiration Biopsy: any advantages over the use of direct finger grip?

    PubMed

    Mayun, A A; Nggada, H A; Abdulazzez, J O; Musa, A B; Pindiga, U H; Khalil, M I

    2013-06-01

    The study seeks to determine the advantages of using the pistol-grip syringe holder in the performance of FNAB over the use of direct finger grip method. The skin is cleaned with gauze soaked in methylated spirit and the lump is located and firmly held between the thumb and fore finger of the free hand. The syringe is held by the out side of the barrel or by pistol-grip, and the needle tip pushed into the lesion. The plunger is partially retracted, creating a negative pressure. The cutting edge of the needle tip frees the cells inside the lesion which are sucked into the fine bore of the needle. The contents of the needle are then emptied on a microscopic slide and thinly smeared. The slides are then fixed in alcohol and later stained. These were examined under the microscope and a comparison between the aspirations using pistol-grip and direct finger grip was made. A total of 266 cases of FNABs were carried out from 1st January to 31st December, 2008. There were 89 breast cases out of which 42 (47%) had pistol-grip method and 47 (53%) had direct finger grip method; 74 thyroid cases out of which 28 (38%) were pistol-grip and 46 (62%) were direct finger grip cases; 56 cases of lymph node FNABs of which 18(32%) and 38 (68%) had pistol-grip and direct finger grip methods respectively. There were 23 cases of salivary gland FNABs having 8 (35%) and 15 (65%) as pistol-grip and direct finger grip methods respectively. Marked cellularity was observed in the majority of cases using both methods of FNABs. This study has shown that the use of pistol-grip syringe holder in the performance of FNABs has no significant advantage compared to the direct finger grip method.

  16. Grip form and graphomotor control in preschool children.

    PubMed

    Burton, A W; Dancisak, M J

    2000-01-01

    The purpose of this study was to examine the utility of the grip scale presented by Schneck and Henderson, the effect of grip form on drawing accuracy, and the effect of implement diameter on grip form and drawing accuracy. Sixty boys and girls who were 3, 4, and 5 years of age performed 20 trials of a precision drawing task, 4 trials each with five implements of varying diameters (4.7, 7.9, 11.1, 14.3, and 17.5 mm). First, all 1,200 grips could be coded according to Schneck and Henderson's 10-grip whole-configuration assessment system, but the interrater reliability was lower than expected (.67 proportion of perfect agreement). Second, using Schneck's five-level scoring system, the level of grip significantly affected drawing accuracy, with the highest grip level used most often with the highest accuracy scores and the lowest observed grip level used most often with the lowest accuracy scores. Third, increasing implement diameter led to significantly lower level grips but did not significantly affect accuracy. Therapists are recommended to use Schneck and Henderson's 10-grip scale only for documenting the persons' grips and changes in their grips, but if comparisons between individual persons are desired, then Schneck's five-level scale, which affords greater generalizability, should be used. Further, children with graphomotor performance deficits are not likely to benefit from grip manipulations because such strategies were shown to make better only performance that is already good.

  17. Microscopic vision modeling method by direct mapping analysis for micro-gripping system with stereo light microscope.

    PubMed

    Wang, Yuezong; Zhao, Zhizhong; Wang, Junshuai

    2016-04-01

    We present a novel and high-precision microscopic vision modeling method, which can be used for 3D data reconstruction in micro-gripping system with stereo light microscope. This method consists of four parts: image distortion correction, disparity distortion correction, initial vision model and residual compensation model. First, the method of image distortion correction is proposed. Image data required by image distortion correction comes from stereo images of calibration sample. The geometric features of image distortions can be predicted though the shape deformation of lines constructed by grid points in stereo images. Linear and polynomial fitting methods are applied to correct image distortions. Second, shape deformation features of disparity distribution are discussed. The method of disparity distortion correction is proposed. Polynomial fitting method is applied to correct disparity distortion. Third, a microscopic vision model is derived, which consists of two models, i.e., initial vision model and residual compensation model. We derive initial vision model by the analysis of direct mapping relationship between object and image points. Residual compensation model is derived based on the residual analysis of initial vision model. The results show that with maximum reconstruction distance of 4.1mm in X direction, 2.9mm in Y direction and 2.25mm in Z direction, our model achieves a precision of 0.01mm in X and Y directions and 0.015mm in Z direction. Comparison of our model with traditional pinhole camera model shows that two kinds of models have a similar reconstruction precision of X coordinates. However, traditional pinhole camera model has a lower precision of Y and Z coordinates than our model. The method proposed in this paper is very helpful for the micro-gripping system based on SLM microscopic vision. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Grip Strength and Its Relationship to Police Recruit Task Performance and Injury Risk: A Retrospective Cohort Study

    PubMed Central

    Stierli, Michael; Hinton, Benjamin

    2017-01-01

    Suitable grip strength is a police occupational requirement. The aim of this study was to investigate the association between grip strength, task performance and injury risk in a police population. Retrospective data of police recruits (n = 169) who had undergone basic recruit training were provided, including handgrip strength results, occupational task performance measures (consisting of police task simulations [SIM], tactical options [TACOPS] and marksmanship assessments) and injury records. Left hand grip strength (41.91 ± 8.29 kg) measures showed a stronger correlation than right hand grip strength (42.15 ± 8.53 kg) with all outcome measures. Recruits whose grip strength scores were lower were significantly more susceptible to failing the TACOPS occupational task assessment than those with greater grip strength scores, with significant (p ≤ 0.003) weak to moderate, positive correlations found between grip strength and TACOPS performance. A significant (p < 0.0001) correlation was found between grip strength, most notably of the left hand, and marksmanship performance, with those performing better in marksmanship having higher grip strength. Left hand grip strength was significantly associated with injury risk (r = −0.181, p = 0.018) but right hand grip strength was not. A positive association exists between handgrip strength and police recruit task performance (notably TACOPS and marksmanship) with recruits who scored poorly on grip strength being at greatest risk of occupational assessment task failure. PMID:28825688

  19. Grip Strength and Its Relationship to Police Recruit Task Performance and Injury Risk: A Retrospective Cohort Study.

    PubMed

    Orr, Robin; Pope, Rodney; Stierli, Michael; Hinton, Benjamin

    2017-08-21

    Suitable grip strength is a police occupational requirement. The aim of this study was to investigate the association between grip strength, task performance and injury risk in a police population. Retrospective data of police recruits (n = 169) who had undergone basic recruit training were provided, including handgrip strength results, occupational task performance measures (consisting of police task simulations [SIM], tactical options [TACOPS] and marksmanship assessments) and injury records. Left hand grip strength (41.91 ± 8.29 kg) measures showed a stronger correlation than right hand grip strength (42.15 ± 8.53 kg) with all outcome measures. Recruits whose grip strength scores were lower were significantly more susceptible to failing the TACOPS occupational task assessment than those with greater grip strength scores, with significant ( p ≤ 0.003) weak to moderate, positive correlations found between grip strength and TACOPS performance. A significant ( p < 0.0001) correlation was found between grip strength, most notably of the left hand, and marksmanship performance, with those performing better in marksmanship having higher grip strength. Left hand grip strength was significantly associated with injury risk ( r = -0.181, p = 0.018) but right hand grip strength was not. A positive association exists between handgrip strength and police recruit task performance (notably TACOPS and marksmanship) with recruits who scored poorly on grip strength being at greatest risk of occupational assessment task failure.

  20. Selective Influences of Precision and Power Grips on Speech Categorization.

    PubMed

    Tiainen, Mikko; Tiippana, Kaisa; Vainio, Martti; Peromaa, Tarja; Komeilipoor, Naeem; Vainio, Lari

    2016-01-01

    Recent studies have shown that articulatory gestures are systematically associated with specific manual grip actions. Here we show that executing such actions can influence performance on a speech-categorization task. Participants watched and/or listened to speech stimuli while executing either a power or a precision grip. Grip performance influenced the syllable categorization by increasing the proportion of responses of the syllable congruent with the executed grip (power grip-[ke] and precision grip-[te]). Two follow-up experiments indicated that the effect was based on action-induced bias in selecting the syllable.

  1. Associations of Grip Strength and Change in Grip Strength With All-Cause and Cardiovascular Mortality in a European Older Population

    PubMed Central

    Prasitsiriphon, Orawan; Pothisiri, Wiraporn

    2018-01-01

    Objective: (1) To examine the associations between 3 measures of grip strength: static grip strength, change in grip strength, and the combination of grip strength and its change, with all-cause and cardiovascular mortality, and (2) to determine which measure is the most powerful predictor of all-cause and cardiovascular mortality among the European older population. Method: Data come from the first 4 waves of the Survey of Health, Ageing and Retirement in Europe (SHARE). A Cox proportional hazard model and a competing risk regression model were used to assess the associations. To determine the best predictor, Akaike information criterion was applied. Results: Grip strength and the combination of grip strength and its change were associated with all-cause and cardiovascular mortality. Change in grip strength was correlated with only all-cause mortality. Among the 3 measures, the static measure of grip strength was the best predictor of cardiovascular mortality whereas the combined measure is that of all-cause mortality. Discussion: Grip strength is a significant indicator of all-cause and cardiovascular mortality. The combination of grip strength and its change can be used to increase the accuracy for prediction of all-cause mortality among older persons.

  2. Helical grip for the cable cars of San Francisco

    NASA Technical Reports Server (NTRS)

    Peyran, R. J.

    1979-01-01

    A helical cable car grip to minimize high maintenance costs of San Francisco's cable car operation is presented. The grip establishes a rolling contact between the cable and grip to reduce sliding friction and associated cable wear. The design, development, and testing of the helical cable car grip are described.

  3. Level II Ergonomic Analyses, Dover AFB, DE

    DTIC Science & Technology

    1999-02-01

    1.5" (2.5-3.8 cm). X Grip design requires fingertip grip. Grip dimensions 3"x3" xl 3/4" * Grip Diameter for a fingertip grip tool should be... anthropometry , engineering, and kinesiology. The first three sciences help to define worker capabilities and limitations (e.g., how much hand strength

  4. Wire Test Grip Fixture

    NASA Technical Reports Server (NTRS)

    Burke, Christopher S.

    2011-01-01

    Wire-testing issues, such as the gripping strains imposed on the wire, play a critical role in obtaining clean data. In a standard test frame fitted with flat wedge grips, the gripping action alone creates stresses on the wire specimen that cause the wire to fail at the grip location. A new test frame, which is outfitted with a vacuum chamber, negated the use of any conventional commercially available wire test fixtures, as only 7 in. (17.8 cm) existed between the grip faces. An innovative grip fixture was designed to test thin gauge wire for a variety of applications in an existing Instron test frame outfitted with a vacuum chamber.

  5. Influence of central set on anticipatory and triggered grip-force adjustments

    NASA Technical Reports Server (NTRS)

    Winstein, C. J.; Horak, F. B.; Fisher, B. E.; Peterson, B. W. (Principal Investigator)

    2000-01-01

    The effects of predictability of load magnitude on anticipatory and triggered grip-force adjustments were studied as nine normal subjects used a precision grip to lift, hold, and replace an instrumented test object. Experience with a predictable stimulus has been shown to enhance magnitude scaling of triggered postural responses to different amplitudes of perturbations. However, this phenomenon, known as a central-set effect, has not been tested systematically for grip-force responses in the hand. In our study, predictability was manipulated by applying load perturbations of different magnitudes to the test object under conditions in which the upcoming load magnitude was presented repeatedly or under conditions in which the load magnitudes were presented randomly, each with two different pre-load grip conditions (unconstrained and constrained). In constrained conditions, initial grip forces were maintained near the minimum level necessary to prevent pre-loaded object slippage, while in unconstrained conditions, no initial grip force restrictions were imposed. The effect of predictable (blocked) and unpredictable (random) load presentations on scaling of anticipatory and triggered grip responses was tested by comparing the slopes of linear regressions between the imposed load and grip response magnitude. Anticipatory and triggered grip force responses were scaled to load magnitude in all conditions. However, regardless of pre-load grip force constraint, the gains (slopes) of grip responses relative to load magnitudes were greater when the magnitude of the upcoming load was predictable than when the load increase was unpredictable. In addition, a central-set effect was evidenced by the fewer number of drop trials in the predictable relative to unpredictable load conditions. Pre-load grip forces showed the greatest set effects. However, grip responses showed larger set effects, based on prediction, when pre-load grip force was constrained to lower levels. These results suggest that anticipatory processes pertaining to load magnitude permit the response gain of both voluntary and triggered rapid grip force adjustments to be set, at least partially, prior to perturbation onset. Comparison of anticipatory set effects for reactive torque and lower extremity EMG postural responses triggered by surface translation perturbations suggests a more general rule governing anticipatory processes.

  6. Selective deficits of grip force control during object manipulation in patients with reduced sensibility of the grasping digits.

    PubMed

    Nowak, Dennis A; Hermsdörfer, Joachim

    2003-09-01

    Persons with impaired manual sensibility frequently report problems to use the hand in manipulative tasks, such as using tools or buttoning a shirt. At least two control processes determine grip forces during voluntary object manipulation. Anticipatory force control specifies the motor commands on the basis of predictions about physical object properties and the consequences of our own actions. Feedback sensory information from the grasping digits, representing mechanical events at the skin-object interface, automatically modifies grip force according to the actual loading requirements and updates sensorimotor memories to support anticipatory grip force control. We investigated grip force control in nine patients with moderately impaired tactile sensibility of the grasping digits and in nine sex- and age-matched healthy controls lifting and holding an instrumented object. In healthy controls grip force was adequately scaled to the weight of the object to be lifted. The grip force was programmed to smoothly change in parallel with load force over the entire lifting movement. In particular, the grip force level was regulated in an economical way to be always slightly higher than the minimum required to prevent the object slipping. The temporal coupling between the grip and load force profiles achieved a high precision with the maximum grip and load forces coinciding closely in time. For the temporal regulation of the grip force profile patients with impaired tactile sensibility maintained the close co-ordination between proximal arm muscles, responsible for the lifting movement and the fingers stabilising the grasp. Maximum grip force coincided with maximum acceleration of the lifting movement. However, patients employed greater maximum grip forces and greater grip forces to hold the object unsupported when compared with controls. Our results give further evidence to the suggestion that during manipulation of objects with known physical properties the anticipatory temporal regulation of the grip force profile is centrally processed and less under sensory feedback control. In contrast, sensory afferent information from the grasping fingers plays a dominant role for the efficient scaling of the grip force level according to actual loading requirements.

  7. Cell shape characterization and classification with discrete Fourier transforms and self-organizing maps.

    PubMed

    Kriegel, Fabian L; Köhler, Ralf; Bayat-Sarmadi, Jannike; Bayerl, Simon; Hauser, Anja E; Niesner, Raluca; Luch, Andreas; Cseresnyes, Zoltan

    2018-03-01

    Cells in their natural environment often exhibit complex kinetic behavior and radical adjustments of their shapes. This enables them to accommodate to short- and long-term changes in their surroundings under physiological and pathological conditions. Intravital multi-photon microscopy is a powerful tool to record this complex behavior. Traditionally, cell behavior is characterized by tracking the cells' movements, which yields numerous parameters describing the spatiotemporal characteristics of cells. Cells can be classified according to their tracking behavior using all or a subset of these kinetic parameters. This categorization can be supported by the a priori knowledge of experts. While such an approach provides an excellent starting point for analyzing complex intravital imaging data, faster methods are required for automated and unbiased characterization. In addition to their kinetic behavior, the 3D shape of these cells also provide essential clues about the cells' status and functionality. New approaches that include the study of cell shapes as well may also allow the discovery of correlations amongst the track- and shape-describing parameters. In the current study, we examine the applicability of a set of Fourier components produced by Discrete Fourier Transform (DFT) as a tool for more efficient and less biased classification of complex cell shapes. By carrying out a number of 3D-to-2D projections of surface-rendered cells, the applied method reduces the more complex 3D shape characterization to a series of 2D DFTs. The resulting shape factors are used to train a Self-Organizing Map (SOM), which provides an unbiased estimate for the best clustering of the data, thereby characterizing groups of cells according to their shape. We propose and demonstrate that such shape characterization is a powerful addition to, or a replacement for kinetic analysis. This would make it especially useful in situations where live kinetic imaging is less practical or not possible at all. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  8. Multiple regression analysis of factors influencing dominant hand grip strength in an adult Malaysian population.

    PubMed

    Hossain, M G; Zyroul, R; Pereira, B P; Kamarul, T

    2012-01-01

    Grip strength is an important measure used to monitor the progression of a condition, and to evaluate outcomes of treatment. We assessed how various physical and social factors predict normal grip strength in an adult Malaysian population of mixed Asian ethnicity (254 men, 246 women). Grip strength was recorded using the Jamar dynamometer. The mean grip strength for the dominant hand was 29.8 kg for men and 17.6 kg for women. Multiple regression analysis demonstrated that the dominant hand grip strength was positively associated with height and body mass index, and negatively associated with age for both sexes. Dominant hand grip strength was related to work status for men (p < 0.05) but not for women. However, there was no difference in grip strength among ethnic groups.

  9. Proximal forearm extensor muscle strain is reduced when driving nails using a shock-controlled hammer.

    PubMed

    Buchanan, Kimberly A; Maza, Maria; Pérez-Vázquez, Carlos E; Yen, Thomas Y; Kijowski, Richard; Liu, Fang; Radwin, Robert G

    2016-10-01

    Repetitive hammer use has been associated with strain and musculoskeletal injuries. This study investigated if using a shock-control hammer reduces forearm muscle strain by observing adverse physiological responses (i.e. inflammation and localized edema) after use. Three matched framing hammers were studied, including a wood-handle, steel-handle, and shock-control hammer. Fifty volunteers were randomly assigned to use one of these hammers at a fatiguing pace of one strike every second, to seat 20 nails in a wood beam. Magnetic resonance imaging was used to scan the forearm muscles for inflammation before the task, immediately after hammering, and one to two days after. Electromyogram signals were measured to estimate grip exertions and localized muscle fatigue. High-speed video was used to calculate the energy of nail strikes. While estimated grip force was similar across the three hammers, the shock-control hammer had 40% greater kinetic energy upon impact and markedly less proximal extensor muscle edema than the wood-handle and steel-handle hammers, immediately after use (p<.05). Less edema observed for the shock-control hammer suggests that isolating handle shock can mitigate strain in proximal forearm extensor muscles. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Quantification of hand function by power grip and pinch strength force measurements in ulnar nerve lesion simulated by ulnar nerve block.

    PubMed

    Wachter, Nikolaus Johannes; Mentzel, Martin; Krischak, Gert D; Gülke, Joachim

    2017-06-24

    In the assessment of hand and upper limb function, grip strength is of the major importance. The measurement by dynamometers has been established. In this study, the effect of a simulated ulnar nerve lesion on different grip force measurements was evaluated. In 25 healthy volunteers, grip force measurement was done by the JAMAR dynamometer (Fabrication Enterprises Inc, Irvington, NY) for power grip and by a pinch strength dynamometer for tip pinch strength, tripod grip, and key pinch strength. A within-subject research design was used in this prospective study. Each subject served as the control by preinjection measurements of grip and pinch strength. Subsequent measurements after ulnar nerve block were used to examine within-subject change. In power grip, there was a significant reduction of maximum grip force of 26.9% with ulnar nerve block compared with grip force without block (P < .0001). Larger reductions in pinch strength were observed with block: 57.5% in tip pinch strength (P < .0001), 61.0% in tripod grip (P < .0001), and 58.3% in key pinch strength (P < .0001). The effect of the distal ulnar nerve block on grip and pinch force could be confirmed. However, the assessment of other dimensions of hand strength as tip pinch, tripod pinch and key pinch had more relevance in demonstrating hand strength changes resulting from an distal ulnar nerve lesion. The measurement of tip pinch, tripod grip and key pinch can improve the follow-up in hand rehabilitation. II. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  11. Grips for Lightweight Tensile Specimens

    NASA Technical Reports Server (NTRS)

    Witte, William G., Jr.; Gibson, Walter D.

    1987-01-01

    Set of grips developed for tensile testing of lightweight composite materials. Double-wedge design substantially increases gripping force and reduces slippage. Specimen held by grips made of hardened wedges. Assembly screwed into load cell in tensile-testing machine.

  12. Effects of grip force on skin conductance measured from a handheld device.

    PubMed

    Tartz, Robert; Vartak, Aniket; King, Jay; Fowles, Don

    2015-01-01

    Skin conductance (SC) reflects stimulus significance and can be measured by integrating electrodes directly onto a smartphone housing such that they are naturally contacted when gripped. However, grip artifacts naturally arise during operation since grip forces can vary. We explored the effects of grip force on SC to determine feasibility and to draw guidelines on artifact mitigation. For this purpose, a prototype was built with integrated SC electrodes with colocated force sensors, and data was collected from 24 participants gripping the prototype across different grip force conditions. Our analysis showed that static forces greater than 2.0 N were associated with significant SC distortion, and artifacts induced from dynamic grip forces were buffered if the SC level was at least 1.1 microsiemens. Our findings are relevant for future applications of SC sensing on smartphones, which may enable interesting and highly contextual user experiences. Copyright © 2014 Society for Psychophysiological Research.

  13. Grip strength and its determinants among older people in different healthcare settings

    PubMed Central

    Roberts, Helen C; Syddall, Holly; Butchart, Joe; Sparkes, Jonathan; Ritchie, Jan; Kerr, Alastair; Cooper, Cyrus; Sayer, Avan Aihie

    2013-01-01

    Background Low muscle strength is central to geriatric syndromes including sarcopenia and frailty. It is well described in community dwelling older people but the epidemiology of grip strength of older people in rehabilitation or long term care has been little explored. Objective To describe grip strength of older people in rehabilitation and nursing home settings. Design Cross-sectional epidemiological study. Setting 3 healthcare settings in one town. Subjects 101 inpatients on a rehabilitation ward, 47 community rehabilitation referrals and 100 nursing home residents. Methods Grip strength, age, height, weight, body mass index, number of co-morbidities and medications, Barthel score, mini mental state examination (MMSE), nutritional status, and number of falls in the last year were recorded. Results Grip strength differed substantially between healthcare settings for both men and women (p<0.0001). Nursing home residents had the lowest age-adjusted mean grip strength and community rehabilitation referrals the highest. Broadly higher grip strength was associated in univariate analyses with younger age, greater height and weight, fewer comorbidities, higher Barthel score, higher MMSE score, better nutritional status and fewer falls. However after mutual adjustment for these factors, the difference in grip strength between settings remained significant. Barthel score was the characteristic most strongly associated with grip strength. Conclusions Older people in rehabilitation and care home settings had lower grip strength than reported for those living at home. Furthermore grip strength varied widely between healthcare settings independent of known major influences. Further research is required to ascertain whether grip strength may help identify people at risk of adverse health outcomes within these settings. PMID:23926093

  14. ALTERED PHALANX FORCE DIRECTION DURING POWER GRIP FOLLOWING STROKE

    PubMed Central

    Enders, Leah R.

    2015-01-01

    Many stroke survivors with severe impairment can grasp only with a power grip. Yet, little knowledge is available on altered power grip after stroke, other than reduced power grip strength. This study characterized stroke survivors’ static power grip during 100% and 50% maximum grip. Each phalanx force’s angular deviation from the normal direction and its contribution to total normal force was compared for 11 stroke survivors and 11 age-matched controls. Muscle activities and skin coefficient of friction (COF) were additionally compared for another 20 stroke and 13 age-matched control subjects. The main finding was that stroke survivors gripped with a 34% greater phalanx force angular deviation of 19±2° compared to controls of 14±1° (p<.05). Stroke survivors’ phalanx force angular deviation was closer to the 23° threshold of slippage between the phalanx and grip surface, which may explain increased likelihood of object dropping in stroke survivors. In addition, this altered phalanx force direction decreases normal grip force by tilting the force vector, indicating a partial role of phalanx force angular deviation in reduced grip strength post stroke. Greater phalanx force angular deviation may biomechanically result from more severe underactivation of stroke survivors’ first dorsal interosseous (FDI) and extensor digitorum communis (EDC) muscles compared to their flexor digitorum superficialis (FDS) or somatosensory deficit. While stroke survivors’ maximum power grip strength was approximately half of the controls’, the distribution of their remaining strength over the fingers and phalanges did not differ, indicating evenly distributed grip force reduction over the entire hand. PMID:25795079

  15. Cortical and reticular contributions to human precision and power grip.

    PubMed

    Tazoe, Toshiki; Perez, Monica A

    2017-04-15

    The corticospinal tract contributes to the control of finger muscles during precision and power grip. We explored the neural mechanisms contributing to changes in corticospinal excitability during these gripping configurations. Motor evoked potentials (MEPs) elicited by cortical, but not by subcortical, stimulation were more suppressed during power grip compared with precision grip and index finger abduction. Intracortical inhibition was more reduced during power grip compared with the other tasks. An acoustic startle cue, a stimulus that engages the reticular system, suppressed MEP size during power grip to a lesser extent than during the other tasks at a cortical level and this positively correlated with changes in intracortical inhibition. Our findings suggest that changes in corticospinal excitability during gross more than fine finger manipulations are largely cortical in origin and that the reticular system contributed, at least in part, to these effects. It is well accepted that the corticospinal tract contributes to the control of finger muscles during precision and power grip in humans but the neural mechanisms involved remain poorly understood. Here, we examined motor evoked potentials elicited by cortical and subcortical stimulation of corticospinal axons (MEPs and CMEPs, respectively) and the activity in intracortical circuits (suppression of voluntary electromyography) and spinal motoneurons (F-waves) in an intrinsic hand muscle during index finger abduction, precision grip and power grip. We found that the size of MEPs, but not CMEPs, was more suppressed during power grip compared with precision grip and index finger abduction, suggesting a cortical origin for these effects. Notably, intracortical inhibition was more reduced during power grip compared with the other tasks. To further examine the origin of changes in intracortical inhibition we assessed the contribution of the reticular system, which projects to cortical neurons, and projects to spinal motoneurons controlling hand muscles. An acoustic startle cue, which engages the reticular system, suppressed MEP size during power grip to a lesser extent than during the other tasks and this positively correlated with changes in intracortical inhibition. A startle cue decreased intracortical inhibition, but not CMEPs, during power grip. F-waves remained unchanged across conditions. Our novel findings show that changes in corticospinal excitability present during power grip compared with fine finger manipulations are largely cortical in origin and suggest that the reticular system contributed, at least in part, to these effects. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  16. Shape of isolated domains in lithium tantalate single crystals at elevated temperatures

    NASA Astrophysics Data System (ADS)

    Shur, V. Ya.; Akhmatkhanov, A. R.; Chezganov, D. S.; Lobov, A. I.; Baturin, I. S.; Smirnov, M. M.

    2013-12-01

    The shape of isolated domains has been investigated in congruent lithium tantalate (CLT) single crystals at elevated temperatures and analyzed in terms of kinetic approach. The obtained temperature dependence of the growing domain shape in CLT including circular shape at temperatures above 190 °C has been attributed to increase of relative input of isotropic ionic conductivity. The observed nonstop wall motion and independent domain growth after merging in CLT as opposed to stoichiometric lithium tantalate have been attributed to difference in wall orientation. The computer simulation has confirmed applicability of the kinetic approach to the domain shape explanation.

  17. Pencil grips, legibility, and speed of fourth-graders' writing in cursive.

    PubMed

    Koziatek, Susan M; Powell, Nancy J

    2003-01-01

    The purpose of this research was to study how the speed and legibility of fourth-graders handwriting was affected by type of pencil grip on the Evaluation Tool of Children's Handwriting-Cursive. Ninety-five typically developing students and 6 students receiving special education services completed the Evaluation Tool of Children's Handwriting-Cursive (ETCH-C). Photographs were taken of their pencil grips while they wrote the alphabet. One-way ANOVAs were calculated to compare legibility rates and writing speeds by type of pencil grip. Ninety-nine of the students used one of four pencil grips including the dynamic tripod (38 students), the dynamic quadrupod (18), the lateral tripod (22), and the lateral quadrupod (21). One student used the four-finger pencil grip and one used the interdigital pencil grip. Mean cursive writing speeds were similar for all pencil grips except for the interdigital grasp. Speeds obtained were slower than recently published fourth-grade speeds ranging from a mean of 29.45 to 34.75 letters per minute. CONCLUSION. This study found the lateral quadrupod and four-finger pencil grips to be as functional as the dynamic tripod, lateral tripod, and dynamic quadrupod pencil grips. This study provides average handwriting speeds for fourth-grade students on the ETCH-C.

  18. Constrained handgrip force decreases upper extremity muscle activation and arm strength.

    PubMed

    Smets, Martin P H; Potvin, James R; Keir, Peter J

    2009-09-01

    Many industrial tasks require repetitive shoulder exertions to be performed with concurrent physical and mental demands. The highly mobile nature of the shoulder predisposes it to injury. The purpose of this study was to determine the effects of simultaneous gripping, at a specified magnitude, on muscle activity and maximal arm force in various directions. Ten female subjects performed maximal arm exertions at two different heights and five directions using both specified (30% maximum voluntary grip) and preferred (self-selected) grip forces. Electromyography was recorded from eight muscles of the right upper extremity. The preferred grip condition produced grip forces that were dependent on the combination of arm height and force direction and were significantly greater (arm force down), lower (to left, up and push forward), or similar to the specified grip condition. Regardless of the magnitude of the preferred grip force, specifying the grip resulted in decreased maximal arm strength (by 18-25%) and muscle activity (by 15-30%) in all conditions, indicating an interfering effect when the grip force was specified by visual target force-matching. Task constraints, such as specific gripping demands, may decrease peak force levels attainable and alter muscle activity. Depending on the nature of task, the amount of relative demand may differ, which should be considered when determining safety thresholds.

  19. Grip force control in individuals with multiple sclerosis.

    PubMed

    Iyengar, Veena; Santos, Marcio J; Ko, Michael; Aruin, Alexander S

    2009-10-01

    Appropriate regulation of grip force is essential in performance of various activities of daily living such as drinking, eating, buttoning a shirt, and so on. The extent to which individuals with multiple sclerosis (MS) are able to regulate grip forces while performing elements of the activities of daily living is largely unknown. . To investigate how individuals with MS control grip force during performance of functional tasks. . This study evaluated the grip force control in selected individuals with MS (n = 9) and healthy control subjects (n = 9) while they performed the task of lifting and placing an instrumented object on a shelf and the task of lifting the object and bringing it close to the mouth to mimic drinking. The grip forces, object acceleration, force ratio, and time lag were recorded and analyzed. . The individuals with MS used significantly larger peak grip force and force ratio than control subjects while performing both tasks and for both hands. In addition, the time lag between the peaks of grip and load forces was significantly longer in individuals with MS. . The application of excessive grip force could predispose individuals with MS to additional fatigue and musculoskeletal overuse trauma. Rehabilitation protocols for the MS population may need to account for increased levels of grip force applied during the performance of functional tasks.

  20. Ergonomic audit of a specially engineered sonic powered toothbrush with unique sensing and control technologies, the Sonicare Flexcare, and the Oral-B Smart Series 5000.

    PubMed

    Hunter, Gail; Burns, Laurie; Bone, Brian; Mintel, Thomas; Jimenez, Eduardo

    2012-01-01

    The presence of ergonomic features can impact the marketplace success of a new product. Metaphase Design Group, Inc., in partnership with the Colgate-Palmolive Company, conducted an ergonomic audit on three electric toothbrushes: a specially engineered sonic powered toothbrush with unique sensing and control technologies, the Sonicare FlexCare, and the Oral-B Smart Series 5000. The ergonomic audit was conducted by Metaphase Design Groups's ergonomic and usability experts. Two experts used the toothbrushes over a one-week period and assessed the performance of each brush against a set of ergonomic principles. The three toothbrushes have some solid ergonomic features. They each have adequate grip zones, provide grip security with elastomeric materials, and provide easy access to the on/off button. The most distinctive feature is the longitudinal shape of the handle of the specially engineered sonic powered toothbrush with unique sensing and control technologies. This handle angles downward at the top end and provides additional advantages through improved grip security and visibility. Yet all three toothbrushes have different opportunities for improvement. The Sonicare Flex Care toothbrush has a cluttered and complicated user interface that is difficult to read. The disadvantages of the Oral-B Smart Series 5000 toothbrush are related to its physical dimensions and audible feedback. The specially engineered sonic powered toothbrush with unique sensing afid control technologies is surprising to use with its changes in speeds, brush movements, and resulting changes in audible feedback.

  1. Comparative study of millennials' (age 20-34 years) grip and lateral pinch with the norms.

    PubMed

    Fain, Elizabeth; Weatherford, Cara

    Cross-sectional research design. Clinical practice continues to use normative data for grip and pinch measurements that were established in 1985. There is no updated norms despite different hand usage patterns in today's society. Measuring and comparing grip and pinch strengths with normative data is a valid method to determine hand function. This research was implemented to compare the grip and pinch measurements obtained from healthy millennials to the established norms and to describe hand usage patterns for millennials. Grip and lateral pinch measurements were obtained from a sample of 237 healthy millennials (ages 20-34 years). Strength scores were statistically lower that older normative data in all millennial grip strengths, with the exception of the women in the age group of 30-34 years. Specifically, this statistically significant trend was observed in all male grip strengths, as well as in women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). However, the lateral pinch data reflected was similar to the older norms with variances of 0.5-1 kg. Current data reflect statistically significant differences from the norms for all male grip measurements, as well as for women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). No statistical significance was observed in the independent-sample t tests for the lateral pinch in men of all age groups. Statistical significance was noted for lateral pinch for female age groups for the left hand (20-24 years) and for bilateral lateral pinches (30-34 years). IV. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  2. Control of Precision Grip Force in Lifting and Holding of Low-Mass Objects

    PubMed Central

    Kimura, Daisuke; Kadota, Koji; Ito, Taro

    2015-01-01

    Few studies have investigated the control of grip force when manipulating an object with an extremely small mass using a precision grip, although some related information has been provided by studies conducted in an unusual microgravity environment. Grip-load force coordination was examined while healthy adults (N = 17) held a moveable instrumented apparatus with its mass changed between 6 g and 200 g in 14 steps, with its grip surface set as either sandpaper or rayon. Additional measurements of grip-force-dependent finger-surface contact area and finger skin indentation, as well as a test of weight discrimination, were also performed. For each surface condition, the static grip force was modulated in parallel with load force while holding the object of a mass above 30 g. For objects with mass smaller than 30 g, on the other hand, the parallel relationship was changed, resulting in a progressive increase in grip-to-load force (GF/LF) ratio. The rayon had a higher GF/LF force ratio across all mass levels. The proportion of safety margin in the static grip force and normalized moment-to-moment variability of the static grip force were also elevated towards the lower end of the object mass for both surfaces. These findings indicate that the strategy of grip force control for holding objects with an extremely small mass differs from that with a mass above 30 g. The data for the contact area, skin indentation, and weight discrimination suggest that a decreased level of cutaneous feedback signals from the finger pads could have played some role in a cost function in efficient grip force control with low-mass objects. The elevated grip force variability associated with signal-dependent and internal noises, and anticipated inertial force on the held object due to acceleration of the arm and hand, could also have contributed to the cost function. PMID:26376484

  3. Design and validation of the Grip-ball for measurement of hand grip strength.

    PubMed

    Jaber, Rana; Hewson, David J; Duchêne, Jacques

    2012-11-01

    The Grip-ball is a new dynamometer used to evaluate grip strength, as well as for use in home-based rehabilitation of the hand and forearm. The Grip-ball consists of pressure and temperature sensors and an electronic wireless communication system contained in an airtight ball. That can be inflated to different pressures. The device has advantages over standard dynamometers in that it looks like a simple ball, and can wirelessly communicate via Bluetooth to any compatible receiver, thus have potential to be used for clinical assessment and rehabilitation in a remote setting. The reliability and reproducibility of the device were assessed for the pressure sensor itself, as well as the relationship between the force applied and the pressure measured by the Grip-ball. The initial validation was performed using the pressure sensor without the ball in order to confirm the accuracy of the sensor used. A second validation study was conducted using the Grip-ball rather than just its sensor to examine the relationship between the pressure measured inside the ball and force applied. The results showed that there is a very good correlation (r=0.997, p<0.05) between the pressure measured by the Grip-ball sensor and that measured by a Vigorimeter, thus confirming the reliability of the sensor used in the Grip-ball. A quadratic regression equation was calculated in order to predict the force applied based on the pressure measured inside the ball, and the initial pressure to which the ball was inflated (R(2)=0.97, standard error 10.9N). Such a finding compares favourably with the variability inherent in Jamar recordings, thus indicating that the Grip-ball could be used to assess grip force. An industrial version of the Grip-ball, which is currently under development, will be able to be used for the entire range of grip force in the population. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. An electromyographic study of the effect of hand grip sizes on forearm muscle activity and golf performance.

    PubMed

    Sorbie, Graeme G; Hunter, Henry H; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike Chris

    2016-01-01

    The study describes the differences in surface electromyography (EMG) activity of two forearm muscles in the lead and trail arm at specific phases of the golf swing using a 7-iron with three different grip sizes among amateur and professional golfers. Fifteen right-handed male golfers performed five golf swings using golf clubs with three different grip sizes. Surface EMG was used to measure muscle activity of the extensor carpi radialis brevis (ECRB) and flexor digitorum superficialis (FDS) on both forearms. There were no significant differences in forearm muscle activity when using the three golf grips within the group of 15 golfers (p > 0.05). When using the undersize grip, club head speed significantly increased (p = 0.044). During the backswing and downswing phases, amateurs produced significantly greater forearm muscle activity with all three grip sizes (p < 0.05). In conclusion, forearm muscle activity is not affected by grip sizes. However, club head speed increases when using undersize grips.

  5. Grip force control during virtual object interaction: effect of force feedback,accuracy demands, and training.

    PubMed

    Gibo, Tricia L; Bastian, Amy J; Okamura, Allison M

    2014-03-01

    When grasping and manipulating objects, people are able to efficiently modulate their grip force according to the experienced load force. Effective grip force control involves providing enough grip force to prevent the object from slipping, while avoiding excessive force to avoid damage and fatigue. During indirect object manipulation via teleoperation systems or in virtual environments, users often receive limited somatosensory feedback about objects with which they interact. This study examines the effects of force feedback, accuracy demands, and training on grip force control during object interaction in a virtual environment. The task required subjects to grasp and move a virtual object while tracking a target. When force feedback was not provided, subjects failed to couple grip and load force, a capability fundamental to direct object interaction. Subjects also exerted larger grip force without force feedback and when accuracy demands of the tracking task were high. In addition, the presence or absence of force feedback during training affected subsequent performance, even when the feedback condition was switched. Subjects' grip force control remained reminiscent of their employed grip during the initial training. These results motivate the use of force feedback during telemanipulation and highlight the effect of force feedback during training.

  6. Deficits of anticipatory grip force control after damage to peripheral and central sensorimotor systems.

    PubMed

    Hermsdörfer, Joachim; Hagl, Elke; Nowak, Dennis A

    2004-11-01

    Healthy subjects adjust their grip force economically to the weight of a hand-held object. In addition, inertial loads, which arise from arm movements with the grasped object, are anticipated by parallel grip force modulations. Internal forward models have been proposed to predict the consequences of voluntary movements. Anesthesia of the fingers impairs grip force economy but the feedforward character of the grip force/load coupling is preserved. To further analyze the role of sensory input for internal forward models and to characterize the consequences of central nervous system damage for anticipatory grip force control, we measured grip force behavior in neurological patients. We tested a group of stroke patients with varying degrees of impaired fine motor control and sensory loss, a single patient with complete and permanent differentation from all tactile and proprioceptive input, and a group of patients with amyotrophic lateral sclerosis (ALS) that exclusively impairs the motor system without affecting sensory modalities. Increased grip forces were a common finding in all patients. Sensory deficits were a strong but not the only predictor of impaired grip force economy. The feedforward mode of grip force control was typically preserved in the stroke patients despite their central sensory deficits, but was severely disturbed in the patient with peripheral sensory deafferentation and in a minority of stroke patients. Moderate deficits of feedforward control were also obvious in ALS patients. Thus, the function of the internal forward model and the precision of grip force production may depend on a complex anatomical and functional network of sensory and motor structures and their interaction in time and space.

  7. Shape of isolated domains in lithium tantalate single crystals at elevated temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shur, V. Ya., E-mail: vladimir.shur@usu.ru; Akhmatkhanov, A. R.; Baturin, I. S.

    2013-12-09

    The shape of isolated domains has been investigated in congruent lithium tantalate (CLT) single crystals at elevated temperatures and analyzed in terms of kinetic approach. The obtained temperature dependence of the growing domain shape in CLT including circular shape at temperatures above 190 °C has been attributed to increase of relative input of isotropic ionic conductivity. The observed nonstop wall motion and independent domain growth after merging in CLT as opposed to stoichiometric lithium tantalate have been attributed to difference in wall orientation. The computer simulation has confirmed applicability of the kinetic approach to the domain shape explanation.

  8. Two-year performance study of porous, thermoset, shape memory polyurethanes intended for vascular medical devices

    NASA Astrophysics Data System (ADS)

    Weems, Andrew C.; Boyle, Anthony J.; Maitland, Duncan J.

    2017-03-01

    The long-term shape-recovery behavior of shape memory polymers has often been shown to be dependent on the length of time the material has been stored in the secondary shape. Typically, recovery performance and shape fixity will decrease with increased time in the secondary shape. In medical materials, a shelf-life is crucial to establish as it sets the upper threshold for device performance in a clinical setting, and a reduction in shape recovery would limit the development of SMP medical devices. Here, we present a two-year study of strain recovery, strain fixity, and shape recovery kinetics for passively and actively actuated SMPs intended for vascular devices. While kinetic experiments using immersion DMA indicate slight material relaxation and a decrease in the time to recovery, these changes are not found for bulk recovery experiments. The results indicate that a two-year shelf-life for these SMPs is very reasonable, as there is no change in the recovery kinetics, strain recovery, or strain fixity associated with this aging time. Further, a thermal accelerated aging test is presented for more rapid testing of the shape memory behavior of these SMPs and is compared with the real time aging results, indicating that this test is a reasonable indicator of the two-year behavior.

  9. Control rod driveline and grapple

    DOEpatents

    Germer, John H.

    1987-01-01

    A control rod driveline and grapple is disclosed for placement between a control rod drive and a nuclear reactor control rod containing poison for parasitic neutron absorption required for reactor shutdown. The control rod is provided with an enlarged cylindrical handle which terminates in an upwardly extending rod to provide a grapple point for the driveline. The grapple mechanism includes a tension rod which receives the upwardly extending handle and is provided with a lower annular flange. A plurality of preferably six grapple segments surround and grip the control rod handle. Each grapple rod segment grips the flange on the tension rod at an interior upper annular indentation, bears against the enlarged cylindrical handle at an intermediate annulus and captures the upwardly flaring frustum shaped handle at a lower and complementary female segment. The tension rods and grapple segments are surrounded by and encased within a cylinder. The cylinder terminates immediately and outward extending annulus at the lower portion of the grapple segments. Excursion of the tension rod relative to the encasing cylinder causes rod release at the handle by permitting the grapple segments to pivot outwardly and about the annulus on the tension rod so as to open the lower defined frustum shaped annulus and drop the rod. Relative movement between the tension rod and cylinder can occur either due to electromagnetic release of the tension rod within defined limits of travel or differential thermal expansion as between the tension rod and cylinder as where the reactor exceeds design thermal limits.

  10. Comparative study on the muscular load of the arms using hair driers.

    PubMed

    Harada, H; Katsuura, T; Kikuchi, Y

    1995-12-01

    The purpose of the present study was to evaluate the muscular load of the arm when combing the hair using different "kuru-kuru" type of hair driers. Ten female students (20-24 years old) volunteered as subjects. Five combing patterns were conducted as follows: 1) comb outer layer of right side of hair using right hand, 2) comb outer layer of left side of hair using right hand, 3) comb inner layer of left side of hair using right hand, 4) comb outer layer of back hair using right hand, and 5) comb inner layer of right side of hair using left hand. Surface EMGs were recorded from M. flexor carpi ulnaris, M. brachioradialis, M. biceps brachii, M. triceps brachii, M. deltoideus and M. trapezius of both sides of body. Integrated EMGs (iEMGs) were used to evaluate muscular load for each of the seven different types of hair driers used. The relationship between iEMGs and weight, center of gravity, diameter, length, and circumference of each hair drier were examined. The weight of hair driers tended to be the effective factor on the muscular load. Muscular load also had a tendency to be affected by the shape of the grips. With regard to the hand size, the longer the thumb length, the smaller is the muscular load. It was suggested that a relatively large diameter of the bulb-shaped grip of the drier gave a smaller muscular load among the hair driers examined in the present experiment.

  11. Correlations among void shape distributions, dynamic damage mode, and loading kinetics [Correlations among spall void shape distributions, damage mode and shock loading kinetics

    DOE PAGES

    Brown, A. D.; Pham, Q.; Fortin, E. V.; ...

    2016-11-10

    Here, three-dimensional x-ray tomography (XRT) provides a nondestructive technique to characterize the size, shape, and location of damage in dynamically loaded metals. A shape-fitting method comprising the inertia tensors of individual damage sites was applied to study differences of spall damage development in face-centered-cubic (FCC) and hexagonal-closed-packed (HCP) multicrystals and for a suite of experiments on high-purity copper to examine the influence of loading kinetics on the spall damage process. Applying a volume-weighted average to the best-fit ellipsoidal aspect-ratios allows a quantitative assessment for determining the extent of damage coalescence present in a shocked metal. It was found that incipientmore » transgranular HCP spall damage nucleates in a lenticular shape and is heavily oriented along particular crystallographic slip directions. In polycrystalline materials, shape distributions indicate that a decrease in the tensile loading rate leads to a transition to coalesced damage dominance and that the plastic processes driving void growth are time dependent.« less

  12. Grip force and force sharing in two different manipulation tasks with bottles.

    PubMed

    Cepriá-Bernal, Javier; Pérez-González, Antonio; Mora, Marta C; Sancho-Bru, Joaquín L

    2017-07-01

    Grip force and force sharing during two activities of daily living were analysed experimentally in 10 right-handed subjects. Four different bottles, filled to two different levels, were manipulated for two tasks: transporting and pouring. Each test subject's hand was instrumented with eight thin wearable force sensors. The grip force and force sharing were significantly different for each bottle model. Increasing the filling level resulted in an increase in grip force, but the ratio of grip force to load force was higher for lighter loads. The task influenced the force sharing but not the mean grip force. The contributions of the thumb and ring finger were higher in the pouring task, whereas the contributions of the palm and the index finger were higher in the transport task. Mean force sharing among fingers was 30% for index, 29% for middle, 22% for ring and 19% for little finger. Practitioner Summary: We analysed grip force and force sharing in two manipulation tasks with bottles: transporting and pouring. The objective was to understand the effects of the bottle features, filling level and task on the contribution of different areas of the hand to the grip force. Force sharing was different for each task and the bottles features affected to both grip force and force sharing.

  13. Mechanical counter-pressure vs. gas-pressurized spacesuit gloves: grip and sensitivity.

    PubMed

    Danaher, Patrick; Tanaka, Kunihiko; Hargens, Alan R

    2005-04-01

    An elastic mechanical counter pressure (MCP) glove for spacesuits is under development. In this study we compared handgrip and pinch grip strength levels for the MCP glove and the current extravehicular mobility unit (EMU) gas-pressurized glove. We employed handgrip and pinch grip dynamometers to assess strength levels and von Frey monofilaments to evaluate hand sensitivity. Tests were conducted with the gloved hand inserted in an evacuation chamber at 200 mmHg below atmospheric pressure to simulate conditions in space. Average bare hand strength was 463 N and decreased to 240 N for EMU and 250 N for MCP. Pinch grip and key grip testing showed no difference among conditions. However, there was a significant decrease in palmar grip strength from 111 N barehanded to 67 N in both gloves. Barehanded endurance time was 160 s and dropped to 63 and 69 s for EMU and MCP, respectively. Sensitivity was significantly better for MCP compared with the EMU. The MCP glove improved hand sensitivity when compared with the EMU glove and performed as well as the EMU glove in terms of overall handgrip strength, endurance at 25% of maximum handgrip strength, pinch grip, palmar grip, and key grip tests. Improvements in fabric composition and glove design may further improve ergonomic and other functional parameters of the MCP glove.

  14. New Approach for Studying Slow Fragmentation Kinetics in FT-ICR: Surface-Induced Dissociation Combined with Resonant Ejection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laskin, Julia; Futrell, Jean H.

    2015-02-01

    We introduce a new approach for studying the kinetics of large ion fragmentation in the gas phase by coupling surface-induced dissociation (SID) in a Fourier transform ion cyclotron resonance mass spectrometer with resonant ejection of selected fragment ions using a relatively short (5 ms) ejection pulse. The approach is demonstrated for singly protonated angiotensin III ions excited by collisions with a self-assembled monolayer of alkylthiol on gold (HSAM). The overall decomposition rate and rate constants of individual reaction channels are controlled by varying the kinetic energy of the precursor ion in a range of 65–95 eV. The kinetics of peptidemore » fragmentation are probed by varying the delay time between resonant ejection and fragment ion detection at a constant total reaction time. RRKM modeling indicates that the shape of the kinetics plots is strongly affected by the shape and position of the energy deposition function (EDF) describing the internal energy distribution of the ion following ion-surface collision. Modeling of the kinetics data provides detailed information on the shape of the EDF and energy and entropy effects of individual reaction channels.« less

  15. Contribution of the Cerebellum in Cue-Dependent Force Changes During an Isometric Precision Grip Task.

    PubMed

    Kutz, Dieter F; Schmid, Barbara C; Meindl, Tobias; Timmann, Dagmar; Kolb, Florian P

    2016-08-01

    The "raspberry task" represents a precision grip task that requires continuous adjustment of grip forces and pull forces. During this task, subjects use a specialised grip rod and have to increase the pull force linearly while the rod is locked. The positions of the fingers are unrestrained and freely selectable. From the finger positions and the geometry of the grip rod, a physical lever was derived which is a comprehensive measurement of the subject's grip behaviour. In this study, the involvement of the cerebellum in establishing cued force changes (CFC) was examined. The auditory stimulus was associated with a motor behaviour that has to be readjusted during an ongoing movement that already started. Moreover, cerebellar involvement on grip behaviour was examined. The results show that patients presenting with degenerating cerebellar disease (CBL) were able to elicit CFC and were additionally able to optimise grip behaviour by minimising the lever. Comparison of the results of CBL with a control group of healthy subjects showed, however, that the CFC incidence was significantly lower and the reduction of the lever was less in CBL. Hence, the cerebellum is involved not only in the classical conditioning of reflexes but also in the association of sensory stimuli with complex changes in motor behaviour. Furthermore, the cerebellum is involved in the optimisation of grip behaviour during ongoing movements. Recent studies lead to the assumption that the cerebello-reticulo-spinal pathway might be important for the reduced optimisation of grip behaviour in CBL.

  16. Effect of custom-made and prefabricated orthoses on grip strength in persons with carpal tunnel syndrome.

    PubMed

    Mlakar, Maja; Ramstrand, Nerrolyn; Burger, Helena; Vidmar, Gaj

    2014-06-01

    Based on the literature, patients with carpal tunnel syndrome are suggested to wear a custom-made wrist orthosis immobilizing the wrist in a neutral position. Many prefabricated orthoses are available on the market, but the majority of those do not assure neutral wrist position. We hypothesized that the use of orthosis affects grip strength in persons with carpal tunnel syndrome in a way that supports preference for custom-made orthoses with neutral wrist position over prefabricated orthoses. Experimental. Comparisons of grip strength for three types of grips (cylindrical, lateral, and pinch) were made across orthosis types (custom-made, prefabricated with wrist in 20° of flexion, and none) on the affected side immediately after fitting, as well as between affected side without orthosis and nonaffected side. Orthosis type did not significantly affect grip strength (p = 0.661). Cylindrical grip was by far the strongest, followed by lateral and pinch grips (p < 0.050). The grips of the affected side were weaker than those of the nonaffected side (p = 0.002). In persons with carpal tunnel syndrome, neither prefabricated orthoses with 20° wrist extension nor custom-made wrist orthoses with neutral wrist position influenced grip strength of the affected hand. Compared to the nonaffected side, the grips of the affected side were weaker. The findings from this study can be used to guide application of orthoses to patients with carpal tunnel syndrome. © The International Society for Prosthetics and Orthotics 2013.

  17. Preserved and impaired aspects of feed-forward grip force control after chronic somatosensory deafferentation.

    PubMed

    Hermsdörfer, J; Elias, Z; Cole, J D; Quaney, B M; Nowak, D A

    2008-01-01

    Although feed-forward mechanisms of grip force control are a prerequisite for skilled object manipulation, somatosensory feedback is essential to acquire, maintain, and adapt these mechanisms. Individuals with complete peripheral deafferentation provide the unique opportunity to study the function of the motor system deprived of somatosensory feedback. Two individuals (GL and IW) with complete chronic deafferentation of the trunk and limbs were tested during cyclic vertical movements of a hand-held object. Such movements induce oscillating loads that are typically anticipated by parallel modulations of the grip force. Load magnitude was altered by varying either the movement frequency or object weight. GL and IW employed excessive grip forces probably reflecting a compensatory mechanism. Despite this overall force increase, both deafferented participants adjusted their grip force level according to the load magnitude, indicating preserved scaling of the background grip force to physical demands. The dynamic modulation of the grip force with the load force was largely absent in GL, whereas in IW only slower movements were clearly affected. The authors hypothesize that the deafferented patients may have utilized visual and vestibular cues and/or an efferent copy of the motor command of the arm movement to scale the grip force level. Severely impaired grip force-load coupling in GL suggests that sensory information is important for maintaining a precise internal model of dynamic grip force control. However, comparably better performance in IW argues for the possibility that alternative cues can be used to trigger a residual internal model.

  18. Effects of hand grip exercise on shoulder joint internal rotation and external rotation peak torque.

    PubMed

    Lee, Dong-Rour; Jong-Soon Kim, Laurentius

    2016-08-10

    The goal of this study is to analyze the effects of hand grip training on shoulder joint internal rotation (IR)/external rotation (ER) peak torque for healthy people. The research was conducted on 23 healthy adults in their 20 s-30 s who volunteered to participate in the experiment. Hand grip power test was performed on both hands of the research subjects before/after the test to study changes in hand grip power. Isokinetic machine was used to measure the concentric IRPT (internal rotation peak torque) and concentric ERPT (external rotation peak torque) at the velocity of 60°/sec, 90°/sec, and 180°/sec before/after the test. Hand grip training was performed daily on the subject's right hand only for four weeks according to exercise program. Finally, hand grip power of both hands and the maximum torque values of shoulder joint IR/ER were measured before/after the test and analyzed. There was a statistically significant difference in the hand grip power of the right hand, which was subject to hand grip training, after the experiment. Also, statistically significant difference for shoulder ERPT was found at 60°/sec. Hand grip training has a positive effect on shoulder joint IRPT/ERPT and therefore can help strengthen muscles around the shoulder without using weight on the shoulder. Consequently, hand grip training would help maintain strengthen the muscles around the shoulder in the early phase of rehabilitation process after shoulder surgery.

  19. The Effects of Bench Press Variations in Competitive Athletes on Muscle Activity and Performance

    PubMed Central

    Saeterbakken, Atle Hole; Mo, Dag-André; Scott, Suzanne; Andersen, Vidar

    2017-01-01

    Abstract The aim of the study was to compare the EMG activity performing 6RM competition style bench press (flat bench-wide grip) with 1) medium and narrow grip widths on a flat bench and 1) inclined and declined bench positions with a wide grip. Twelve bench press athletes competing at national and international level participated in the study. EMG activity was measured in the pectoralis major, anterior and posterior deltoid, biceps brachii, triceps brachii and latissimus dorsi. Non-significant differences in activation were observed between the three bench positions with the exception of 58.5-62.6% lower triceps brachii activation, but 48.3-68.7% greater biceps brachii activation in the inclined bench compared with the flat and declined bench position. Comparing the three grip widths, non-significant differences in activations were observed, with the exception of 25.9-30.5% lower EMG activity in the biceps brachii using a narrow grip, compared to the medium and wide grip conditions. The 6-RM loads were 5.8-11.1% greater using a medium and wide grip compared to narrow grip width and 18.5-21.5% lower in the inclined bench position compared with flat and declined. Comparing the EMG activity during the competition bench press style with either the inclined and declined bench position (wide grip) or using a narrow and medium grip (flat bench), only resulted in different EMG activity in the biceps- and triceps brachii. The 6RM loads varied with each bench press variation and we recommend the use of a wide grip on a flat bench during high load hypertrophy training to bench press athletes. PMID:28713459

  20. The Effects of Bench Press Variations in Competitive Athletes on Muscle Activity and Performance.

    PubMed

    Saeterbakken, Atle Hole; Mo, Dag-André; Scott, Suzanne; Andersen, Vidar

    2017-06-01

    The aim of the study was to compare the EMG activity performing 6RM competition style bench press (flat bench-wide grip) with 1) medium and narrow grip widths on a flat bench and 1) inclined and declined bench positions with a wide grip. Twelve bench press athletes competing at national and international level participated in the study. EMG activity was measured in the pectoralis major, anterior and posterior deltoid, biceps brachii, triceps brachii and latissimus dorsi. Non-significant differences in activation were observed between the three bench positions with the exception of 58.5-62.6% lower triceps brachii activation, but 48.3-68.7% greater biceps brachii activation in the inclined bench compared with the flat and declined bench position. Comparing the three grip widths, non-significant differences in activations were observed, with the exception of 25.9-30.5% lower EMG activity in the biceps brachii using a narrow grip, compared to the medium and wide grip conditions. The 6-RM loads were 5.8-11.1% greater using a medium and wide grip compared to narrow grip width and 18.5-21.5% lower in the inclined bench position compared with flat and declined. Comparing the EMG activity during the competition bench press style with either the inclined and declined bench position (wide grip) or using a narrow and medium grip (flat bench), only resulted in different EMG activity in the biceps- and triceps brachii. The 6RM loads varied with each bench press variation and we recommend the use of a wide grip on a flat bench during high load hypertrophy training to bench press athletes.

  1. Finger-attachment device for the feedback of gripping and pulling force in a manipulating system for brain tumor resection.

    PubMed

    Chinbe, Hiroyuki; Yoneyama, Takeshi; Watanabe, Tetsuyou; Miyashita, Katsuyoshi; Nakada, Mitsutoshi

    2018-01-01

    Development and evaluation of an effective attachment device for a bilateral brain tumor resection robotic surgery system based on the sensory performance of the human index finger in order to precisely detect gripping- and pulling-force feedback. First, a basic test was conducted to investigate the performance of the human index finger in the gripping- and pulling-force feedback system. Based on the test result, a new finger-attachment device was designed and constructed. Then, discrimination tests were conducted to assess the pulling force and the feedback on the hardness of the gripped material. The results of the basic test show the application of pulling force on the side surface of the finger has an advantage to distinguish the pulling force when the gripping force is applied on the finger-touching surface. Based on this result, a finger-attachment device that applies a gripping force on the finger surface and pulling force on the side surface of the finger was developed. By conducting a discrimination test to assess the hardness of the gripped material, an operator can distinguish whether the gripped material is harder or softer than a normal brain tissue. This will help in confirming whether the gripped material is a tumor. By conducting a discrimination test to assess the pulling force, an operator can distinguish the pulling-force resistance when attempting to pull off the soft material. Pulling-force feedback may help avoid the breaking of blood pipes when they are trapped in the gripper or attached to the gripped tissue. The finger-attachment device that was developed for detecting gripping- and pulling-force feedback may play an important role in the development of future neurosurgery robotic systems for precise and safe resection of brain tumors.

  2. Effect of blocking tactile information from the fingertips on adaptation and execution of grip forces to friction at the grasping surface.

    PubMed

    Bilaloglu, Seda; Lu, Ying; Geller, Daniel; Rizzo, John Ross; Aluru, Viswanath; Gardner, Esther P; Raghavan, Preeti

    2016-03-01

    Adaptation of fingertip forces to friction at the grasping surface is necessary to prevent use of inadequate or excessive grip forces. In the current study we investigated the effect of blocking tactile information from the fingertips noninvasively on the adaptation and efficiency of grip forces to surface friction during precision grasp. Ten neurologically intact subjects grasped and lifted an instrumented grip device with 18 different frictional surfaces under three conditions: with bare hands or with a thin layer of plastic (Tegaderm) or an additional layer of foam affixed to the fingertips. The coefficient of friction at the finger-object interface of each surface was obtained for each subject with bare hands and Tegaderm by measuring the slip ratio (grip force/load force) at the moment of slip. We found that the foam layer reduced sensibility for two-point discrimination and pressure sensitivity at the fingertips, but Tegaderm did not. However, Tegaderm reduced static, but not dynamic, tactile discrimination. Adaptation of fingertip grip forces to surface friction measured by the rate of change of peak grip force, and grip force efficiency measured by the grip-load force ratio at lift, showed a proportional relationship with bare hands but were impaired with Tegaderm and foam. Activation of muscles engaged in precision grip also varied with the frictional surface with bare hands but not with Tegaderm and foam. The results suggest that sensitivity for static tactile discrimination is necessary for feedforward and feedback control of grip forces and for adaptive modulation of muscle activity during precision grasp. Copyright © 2016 the American Physiological Society.

  3. Hand function in workers with hand-arm vibration syndrome.

    PubMed

    Cederlund, R; Isacsson, A; Lundborg, G

    1999-01-01

    Hand-arm vibration syndrome has been specially addressed in the Scandinavian countries in recent years, but the syndrome is still not sufficiently recognized in many countries. The object of this preliminary study was to describe the nature and character of vibration-induced impairment in the hands of exposed workers. Twenty symptomatic male workers (aged 28 to 65 years) subjected to vibration by hand-held tools were interviewed about subjective symptoms and activities of daily living and were assessed with a battery of objective tests for sensibility, dexterity, grip function, and grip strength. The test results were compared with normative data. The majority of patients complained of cold intolerance, numbness, pain, sensory impairment, and difficulties in handling manual tools and in handwriting. The various objective tests showed considerable variation in indications of pathologic outcome, revealing differences in sensitivity to detect impaired hand function. Semmes-Weinstein monofilament testing for perception of light touch-deep pressure sensation, the small-object shape identification test, and moving two-point discrimination testing for functional sensibility provided the most indications of pathologic outcomes. The authors conclude that vibration-exposed patients present considerable impairment in hand function.

  4. Kinetic Shapes: Analysis, Verification, and Applications.

    PubMed

    Handz̆ić, Ismet; Reed, Kyle B

    2014-06-01

    A circular shape placed on an incline will roll; similarly, an irregularly shaped object, such as the Archimedean spiral, will roll on a flat surface when a force is applied to its axle. This rolling is dependent on the specific shape and the applied force (magnitude and location). In this paper, we derive formulas that define the behavior of irregular 2D and 3D shapes on a flat plane when a weight is applied to the shape's axle. These kinetic shape (KS) formulas also define and predict shapes that exert given ground reaction forces when a known weight is applied at the axle rotation point. Three 2D KS design examples are physically verified statically with good correlation to predicted values. Motion simulations of unrestrained 2D KS yielded expected results in shape dynamics and self-stabilization. We also put forth practical application ideas and research for 2D and 3D KS such as in robotics and gait rehabilitation.

  5. Shape transitions in strained islands: kinetics versus energetics

    NASA Astrophysics Data System (ADS)

    Shim, Yunsic; Kryukov, Yevgen; Amar, Jacques

    2011-03-01

    Recently, it has been argued that the shape transition from compact to ramified islands observed experimentally in submonolayer Cu/Ni(100) growth is not due to kinetics but can be understood in terms of energetic arguments. In order to determine the responsible mechanisms we have carried out temperature-accelerated dynamics (TAD) simulations as well as energetics calculations. Surprisingly, our results indicate that the strain-energy contribution to the dependence of island-energy on shape is relatively weak. In contrast, our TAD simulations indicate that unexpected concerted motions occurring at step edges may be responsible. The energy barriers for these concerted motions are significantly lower than for Cu/Cu(100) and Ni/Ni(100), decrease with increasing island size, and appear to saturate for islands larger than 300 - 400 atoms. These results suggest that the shape transition is of kinetic origin but is strongly mediated by strain. Supported by NSF-DMR 0907399.

  6. Phase-field modeling of two-dimensional crystal growth with anisotropic diffusion.

    PubMed

    Meca, Esteban; Shenoy, Vivek B; Lowengrub, John

    2013-11-01

    In the present article, we introduce a phase-field model for thin-film growth with anisotropic step energy, attachment kinetics, and diffusion, with second-order (thin-interface) corrections. We are mainly interested in the limit in which kinetic anisotropy dominates, and hence we study how the expected shape of a crystallite, which in the long-time limit is the kinetic Wulff shape, is modified by anisotropic diffusion. We present results that prove that anisotropic diffusion plays an important, counterintuitive role in the evolving crystal shape, and we add second-order corrections to the model that provide a significant increase in accuracy for small supersaturations. We also study the effect of different crystal symmetries and discuss the influence of the deposition rate.

  7. Changes in kinetics and kinematics of handwriting during a prolonged writing task in children with and without dysgraphia.

    PubMed

    Kushki, Azadeh; Schwellnus, Heidi; Ilyas, Faizah; Chau, Tom

    2011-01-01

    Handwriting difficulties or dysgraphia have a profound impact on children's psychosocial development, and yet, 10-30% of school-aged children are reported to experience difficulties mastering this skill. Several studies have examined the nature and biomechanical underpinnings of handwriting difficulties in children with and without dysgraphia. While the majority of these studies have considered short handwriting activities involving a sentence or a paragraph, handwriting quality and speed are reported to vary with the length of the writing task. Further, it is suggested that the biomechanics of handwriting also evolve over extended writing periods, and that these changes may be distinct between children with and without dysgraphia. The nature and specificity of these biomechanical alterations remain unknown. To address this knowledge gap, we examined changes in writing speed, grip forces on the pen barrel, and normal forces on the writing surface, over the course of a 10-min writing task, in a large cohort of 4th grade children with and without dysgraphia. Horizontal stroke speed, grip force and normal force increased over time while vertical stroke speed decreased in all children. These biomechanical changes may be attributable to physical and psychological fatigue and the corresponding compensatory processes invoked by the motor system. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Hand Controller Assembly

    NASA Technical Reports Server (NTRS)

    Bandera, Pablo (Inventor); Buchele, Paul (Inventor)

    2015-01-01

    A user input device for a vehicular electrical system is provided. The user input device includes a handle sized and shaped to be gripped by a human hand and a gimbal assembly within the handle. The gimbal assembly includes a first gimbal component, a second gimbal component coupled to the first gimbal component such that the second gimbal component is rotatable relative to the first gimbal component about a first axis, and a third gimbal component coupled to the second gimbal component such that the third gimbal component is rotatable relative to the second gimbal component about a second axis.

  9. Ulnar digits contribution to grip strength in patients with thumb carpometacarpal osteoarthritis is less than in normal controls.

    PubMed

    Villafañe, Jorge H; Valdes, Kristin; Angulo-Diaz-Parreño, Santiago; Pillastrini, Paolo; Negrini, Stefano

    2015-06-01

    Grip testing is commonly used as an objective measure of strength in the hand and upper extremity and is frequently used clinically as a proxy measure of function. Increasing knowledge of hand biomechanics, muscle strength, and prehension patterns can provide us with a better understanding of the functional capabilities of the hand. The objectives of this study were to determine the contribution of ulnar digits to overall grip strength in individuals with thumb carpometacarpal (CMC) osteoarthritis (OA). Thirty-seven subjects participated in the study. This group consisted of 19 patients with CMC OA (aged 60-88 years) and 18 healthy subjects (60-88 years). Three hand configurations were used by the subjects during grip testing: use of the entire hand (index, middle, ring, and little fingers) (IMRL); use of the index, middle, and ring fingers (IMR); and use of only the index and middle fingers (IM). Grip strength findings for the two groups found that compared to their healthy counterparts, CMC OA patients had, on average, a strength deficiency of 45.6, 35.5, and 28.8 % in IMRL, IMR, and IM, respectively. The small finger contribution to grip is 14.3 % and the ring and small finger contribute 34 % in subjects with CMC OA. Grip strength decreases as the number of digits contributing decreased in both groups. The ulnar digits contribution to grip strength is greater than one third of total grip strength in subjects with CMC OA. Individuals with CMC OA demonstrate significantly decreased grip strength when compared to their healthy counterparts.

  10. Grip strength and body composition in Turkana pastoralist children and adolescents.

    PubMed

    Little, Michael A

    2017-03-01

    In an earlier study, age changes and sex differences in grip strength were documented for adult Turkana pastoralists of Kenya (Little and Johnson, 1986). The objective here is to characterize age changes and sex differences in grip strength of Turkana children and adolescents in the context of arm lean tissue composition, and in comparison with other African, African-American, and non-Western populations. Anthropometric measurements, derived body composition values, and grip strength measures (maximum voluntary contraction) were taken on a sample of 232 nomadic Turkana pastoralist children (94 boys and 138 girls) aged 3 to 21 years. Relationships were tested between grip strength (in Newtons) and mid-upper arm (brachium) lean tissue cross-sectional areas. Comparisons were made among several different ethnic groups. Turkana children and adolescents had low arm muscle (derived lean tissue) and grip strength values when compared with U.S. NHANES percentile references. Girls' percentile rankings were greater than boys' percentile rankings for muscle and for grip strength. Both boys and girls were intermediate when compared with other non-Western populations and U.S. strength grip reference values. Correlations between grip strength and arm lean tissue areas were highly significant for both boys and girls. The greater relative muscle size and grip strength values of late adolescent girls compared to boys is consistent with an earlier study of adults. The difference is likely to result from greater physical subsistence activity and greater access to food in girls than in boys. Several suggestions are given to explain why Turkana youths have relatively small muscle sizes. © 2016 Wiley Periodicals, Inc.

  11. Proximal arm kinematics affect grip force-load force coordination

    PubMed Central

    Vermillion, Billy C.; Lum, Peter S.

    2015-01-01

    During object manipulation, grip force is coordinated with load force, which is primarily determined by object kinematics. Proximal arm kinematics may affect grip force control, as proximal segment motion could affect control of distal hand muscles via biomechanical and/or neural pathways. The aim of this study was to investigate the impact of proximal kinematics on grip force modulation during object manipulation. Fifteen subjects performed three vertical lifting tasks that involved distinct proximal kinematics (elbow/shoulder), but resulted in similar end-point (hand) trajectories. While temporal coordination of grip and load forces remained similar across the tasks, proximal kinematics significantly affected the grip force-to-load force ratio (P = 0.042), intrinsic finger muscle activation (P = 0.045), and flexor-extensor ratio (P < 0.001). Biomechanical coupling between extrinsic hand muscles and the elbow joint cannot fully explain the observed changes, as task-related changes in intrinsic hand muscle activation were greater than in extrinsic hand muscles. Rather, between-task variation in grip force (highest during task 3) appears to contrast to that in shoulder joint velocity/acceleration (lowest during task 3). These results suggest that complex neural coupling between the distal and proximal upper extremity musculature may affect grip force control during movements, also indicated by task-related changes in intermuscular coherence of muscle pairs, including intrinsic finger muscles. Furthermore, examination of the fingertip force showed that the human motor system may attempt to reduce variability in task-relevant motor output (grip force-to-load force ratio), while allowing larger fluctuations in output less relevant to task goal (shear force-to-grip force ratio). PMID:26289460

  12. Association between Race, Household Income and Grip Strength in Middle- and Older-Aged Adults.

    PubMed

    Thorpe, Roland J Jr; Simonsick, Eleanor; Zonderman, Alan; Evans, Michelle K

    2016-10-20

    Poor grip strength is an indicator of frailty and a precursor to functional limitations. Although poor grip strength is more prevalent in older disabled African American women, little is known about the association between race and poverty-related disparities and grip strength in middle-aged men and women. We examined the cross-sectional relationship between race, socioeconomic status as assessed by household income, and hand grip strength in men and women in the Healthy Aging in Neighborhoods of Diversity across the Life Span study. General linear models examined grip strength (maximum of two trials on both sides) by race and household income adjusted for age, weight, height, hand pain, education, insurance status, family income, and two or more chronic conditions. Of 2,091 adults, 422(45.4%) were male, 509(54.8%) were African American, and 320 (34.5%) were living in households with incomes below 125% of the federal poverty level (low SES). In adjusted models, African American women had greater grip strength than White women independent of SES (low income household: 29.3 vs 26.9 kg and high income household: 30.5 vs. 28.3kg; P<.05 for both); whereas in men, only African Americans in the high income household group had better grip strength than Whites (46.3 vs. 43.2; P<.05). The relationship between grip strength, race and SES as assessed by household income varied in this cohort. Efforts to develop grip strength norms and cut points that indicate frailty and sarcopenia may need to be race- and income-specific.

  13. Comparison of grip and pinch strength in young women with and without hyperkyphosis: A cross-sectional study.

    PubMed

    Yoosefinejad, Amin Kordi; Ghaffarinejad, Farahnaz; Hemati, Mahbubeh; Jamshidi, Narges

    2018-05-21

    Hyperkyphosis is a common postural defect with high prevalence in the 20 to 50 year old population. It appears to compromise proximal scapular stability. Grip and pinch strength are used to evaluate general upper extremity function. The aim of this study was to compare pinch and grip strength between young women with and without hyperkyphosis. Thirty young women (18-40 years old) with hyperkyphosis and 30 healthy women matched for age and body mass index participated in the study. Hyperkyphosis was confirmed by measuring the kyphosis angle with a flexible ruler. Grip strength was measured with the Waisa method and a dynamometer. Pinch strength was assessed with a pinch meter. Grip (P= 0.03) and pinch strength (P= 0.04) were significantly lower in women with hyperkyphosis compared to the control group. Kyphosis angle correlated weakly with grip (r= 0.26) and pinch strength (r= 0.23). Hyperkyphotic posture has led to decreased grip and pinch strength compared to people without hyperkyphosis.

  14. PICK1 interacts with ABP/GRIP to regulate AMPA receptor trafficking.

    PubMed

    Lu, Wei; Ziff, Edward B

    2005-08-04

    PICK1 and ABP/GRIP bind to the AMPA receptor (AMPAR) GluR2 subunit C terminus. Transfer of the receptor from ABP/GRIP to PICK1, facilitated by GluR2 S880 phosphorylation, may initiate receptor trafficking. Here we report protein interactions that regulate these steps. The PICK1 BAR domain interacts intermolecularly with the ABP/GRIP linker II region and intramolecularly with the PICK1 PDZ domain. Binding of PKCalpha or GluR2 to the PICK1 PDZ domain disrupts the intramolecular interaction and facilitates the PICK1 BAR domain association with ABP/GRIP. Interference with the PICK1-ABP/GRIP interaction impairs S880 phosphorylation of GluR2 by PKC and decreases the constitutive surface expression of GluR2, the NMDA-induced endocytosis of GluR2, and recycling of internalized GluR2. We suggest that the PICK1 interaction with ABP/GRIP is a critical step in controlling GluR2 trafficking.

  15. The Grip of Gravity

    NASA Astrophysics Data System (ADS)

    Gondhalekar, Prabhakar

    2001-09-01

    Gravity is one of the most inexplicable forces of nature, controlling everything, from the expansion of the Universe to the ebb and flow of ocean tides. The search for the laws of motion and gravitation began more than two thousand years ago, a quest that Prabhakar Gondhalekar recounts in The Grip of Gravity. Beginning with Aristotle and concluding with Planck, Gondhalekar outlines a 'genealogy' of gravity and lucidly explains how previous explanations have shaped the most recent development in the field, string theory. In this work, physicist and astronomer Gondhalekar describes experiments, both planned and proposed, and clearly explains natural phenomena like ocean tides, seasons, ice ages, the formation of planets, stars, and exotic objects like black holes and neutron stars, which are all controlled by gravity. Including anecdotes and thumb-nail sketches of the personalities involved, The Grip of Gravity provides an introduction to the foundation of modern physics and shows how the current developments in string theory may lead to a new and radical interpretation of gravity. Prabhakar Gondhalekar is an Honorary Fellow in the Department of Physics and Astronomy, University College, London. Until his retirement in 1998, he was the head of the Space Astronomy Group at the Rutherford Appleton Laboratory, where he had been a researcher for 18 years. His research has included a number of topics in galactic and extragalactic astronomy, with his major work focusing on the interstellar medium and active galactic nuclei. Gondhalekar has been awarded Royal Society, Leverhulme Trust, and NATO Research Fellowships to do research in universities in the United States and Israel.

  16. Trigger Finger

    MedlinePlus

    ... in a bent position. People whose work or hobbies require repetitive gripping actions are at higher risk ... developing trigger finger include: Repeated gripping. Occupations and hobbies that involve repetitive hand use and prolonged gripping ...

  17. Moving objects with clumsy fingers: how predictive is grip force control in patients with impaired manual sensibility?

    PubMed

    Nowak, Dennis A; Hermsdörfer, Joachim; Marquardt, Christian; Topka, Helge

    2003-03-01

    Anticipatory grip force adjustments to movement-induced load fluctuations of a hand-held object suggest that motion planning is based on an internal forward model of both the external object properties and the dynamics of the own motor apparatus. However, the central nervous system also refers to real time sensory feedback from the grasping digits in order to achieve a highly economical coupling between grip force and the actual loading requirements. We analyzed grip force control during vertical point-to-point arm movements with a hand-held instrumented object in 9 patients with moderately impaired tactile sensibility of the grasping digits due to chronic median nerve compression (n = 3), axonal (n = 3) and demyelinating sensory polyneuropathy (n = 3) in comparison to 9 healthy age- and sex-matched control subjects. Point-to-point arm movements started and ended with the object being held stationary at rest. Load force changes arose from inertial loads related to the movement. A maximum of load force occurred early in upward and near the end of downward movements. Compared to healthy controls, patients with impaired manual sensibility generated similar static grip forces during stationary holding of the object and similar force ratios between maximum grip and load force. These findings reflect effective grip force scaling in relation to the movement-induced loads despite reduced afferent feedback from the grasping digits. For both groups the maxima of grip and load force coincided very closely in time, indicating that the temporal regulation of the grip force profile with the load profile was processed with a similar high precision. In addition, linear regression analyses between grip and load forces during movement-related load increase and load decrease phases revealed a similar precise temporo-spatial coupling between grip and load forces for patients and controls. Our results suggest that the precise and anticipatory adjustment of the grip force profile to the load force profile arising from voluntary arm movements with a hand-held object is centrally mediated and less under sensory feedback control. As suggested by previous investigations, the efficient scaling of the grip force magnitude in relation to the movement-induced loads may be intact when deficits of tactile sensibility from the grasping fingers are moderate.

  18. The handyman's brain: a neuroimaging meta-analysis describing the similarities and differences between grip type and pattern in humans.

    PubMed

    King, M; Rauch, H G; Stein, D J; Brooks, S J

    2014-11-15

    Handgrip is a ubiquitous human movement that was critical in our evolution. However, the differences in brain activity between grip type (i.e. power or precision) and pattern (i.e. dynamic or static) are not fully understood. In order to address this, we performed Activation Likelihood Estimation (ALE) analysis between grip type and grip pattern using functional magnetic resonance imaging (fMRI) data. ALE provides a probabilistic summary of the BOLD response in hundreds of subjects, which is often beyond the scope of a single fMRI experiment. We collected data from 28 functional magnetic resonance data sets, which included a total of 398 male and female subjects. Using ALE, we analyzed the BOLD response during power, precision, static and dynamic grip in a range of forces and age in right handed healthy individuals without physical impairment, cardiovascular or neurological dysfunction using a variety of grip tools, feedback and experimental training. Power grip generates unique activation in the postcentral gyrus (areas 1 and 3b) and precision grip generates unique activation in the supplementary motor area (SMA, area 6) and precentral gyrus (area 4a). Dynamic handgrip generates unique activation in the precentral gyrus (area 4p) and SMA (area 6) and of particular interest, both dynamic and static grip share activation in the area 2 of the postcentral gyrus, an area implicated in the evolution of handgrip. According to effect size analysis, precision and dynamic grip generates stronger activity than power and static, respectively. Our study demonstrates specific differences between grip type and pattern. However, there was a large degree of overlap in the pre and postcentral gyrus, SMA and areas of the frontal-parietal-cerebellar network, which indicates that other mechanisms are potentially involved in regulating handgrip. Further, our study provides empirically based regions of interest, which can be downloaded here within, that can be used to more effectively study power grip in a range of populations and conditions. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Relationship between grip, pinch strengths and anthropometric variables, types of pitch throwing among Japanese high school baseball pitchers.

    PubMed

    Tajika, Tsuyoshi; Kobayashi, Tsutomu; Yamamoto, Atsushi; Shitara, Hitoshi; Ichinose, Tsuyoshi; Shimoyama, Daisuke; Okura, Chisa; Kanazawa, Saeko; Nagai, Ayako; Takagishi, Kenji

    2015-03-01

    Grip and pinch strength are crucially important attributes and standard parameters related to the functional integrity of the hand. It seems significant to investigate normative data for grip and pinch strength of baseball players to evaluate their performance and condition. Nevertheless, few reports have explained the association between grip and pinch strength and anthropometric variables and types of pitch throwing for baseball pitchers. The aim of this study was to measure and evaluate clinical normative data for grip and tip, key, palmar pinch strength and to assess the relationship between these data and anthropometric variables and types of pitch throwing among Japanese high-school baseball pitchers. One hundred-thirty three healthy high school baseball pitchers were examined and had completed a self-administered questionnaire including items related to age, hand dominance, throwing ratio of type of pitch. A digital dynamometer was used to measure grip strength and a pinch gauge to measure tip, key and palmer pinch in both dominant and nondominant side. Body composition was measured by the multi frequency segmental body composition analyzer. Grip strength and tip and palmer pinch strength in dominant side were statistically greater than them in nondominant side (P < 0.05). There were significant associations between grip strength and height (r = 0.33, P < 0.001), body mass (r = 0.50, P < 0.001), BMI (r = 0.37, P < 0.001), muscle mass of upper extremity (r = 0.56, P < 0.001), fat free mass (r = 0.57, P < 0.001), fat mass (r = 0.22, P < 0.05) in dominant side. A stepwise multiple regression analysis revealed that fat free mass and tip, palmer, key pinch strength were predictors of grip strength in dominant side. No statistical significant correlations were found between the throwing ratio of types of pitches thrown and grip strength and tip, key, palmar pinch strength. Our result provides normative values and evidences for grip and pinch strengths in high school baseball pitchers.

  20. Predictive and Reactive Grip Force Responses to Rapid Load Increases in People With Multiple Sclerosis.

    PubMed

    Allgöwer, Kathrin; Kern, Claudia; Hermsdörfer, Joachim

    2017-03-01

    To determine the effects of multiple sclerosis (MS) on predictive and reactive grip force control in a catching task and on clinical tests of hand function. Case-control study with matched-pairs control group. University prevention and rehabilitation center. Participants (N=30) consisted of people with multiple sclerosis (PwMS) (n=15) and healthy controls (n=15), matched for sex, age, and hand dominance. Not applicable. Performance on the Expanded Disability Status Scale (EDSS), Nine-Hole Peg Test (9-HPT), Jebsen-Taylor Hand Function Test (JTHFT), and 2-point discrimination (2PD) was evaluated. To analyze grip force control, blindfolded subjects held a receptacle equipped with grip force and acceleration sensors in their hand. In a catching task, a weight was dropped from (1) the experimenter's hand unexpectedly into the receptacle (reactive force control); and (2) from the subject's opposite hand (predictive force control). Grip forces and time lags were analyzed. PwMS (mean EDSS ± SD, 4.2±1.86) had impairments in the 9-HPT and JTHFT (P<.001). The 2PD did not differ significantly between PwMS and controls. During reactive force control (catching task 1), PwMS showed significantly higher grip forces immediately after impact (P<.05), and a significant prolongation of the time from grip force increase until reaching the peak of grip force (P<.001). PwMS and controls did not differ during predictive force control (catching task 2; P>.1). Exaggerated grip force responses and alterations of timing after an unpredictable perturbation, combined with preserved grip force control during predictable conditions, is a characteristic pattern of fine motor control deficits in MS. Measures of reactive grip force responses may be used to complement neurologic assessments. Further studies exploring the usefulness of these measures should be performed in a broader community of PwMS. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  1. Computational model of precision grip in Parkinson's disease: a utility based approach

    PubMed Central

    Gupta, Ankur; Balasubramani, Pragathi P.; Chakravarthy, V. Srinivasa

    2013-01-01

    We propose a computational model of Precision Grip (PG) performance in normal subjects and Parkinson's Disease (PD) patients. Prior studies on grip force generation in PD patients show an increase in grip force during ON medication and an increase in the variability of the grip force during OFF medication (Ingvarsson et al., 1997; Fellows et al., 1998). Changes in grip force generation in dopamine-deficient PD conditions strongly suggest contribution of the Basal Ganglia, a deep brain system having a crucial role in translating dopamine signals to decision making. The present approach is to treat the problem of modeling grip force generation as a problem of action selection, which is one of the key functions of the Basal Ganglia. The model consists of two components: (1) the sensory-motor loop component, and (2) the Basal Ganglia component. The sensory-motor loop component converts a reference position and a reference grip force, into lift force and grip force profiles, respectively. These two forces cooperate in grip-lifting a load. The sensory-motor loop component also includes a plant model that represents the interaction between two fingers involved in PG, and the object to be lifted. The Basal Ganglia component is modeled using Reinforcement Learning with the significant difference that the action selection is performed using utility distribution instead of using purely Value-based distribution, thereby incorporating risk-based decision making. The proposed model is able to account for the PG results from normal and PD patients accurately (Ingvarsson et al., 1997; Fellows et al., 1998). To our knowledge the model is the first model of PG in PD conditions. PMID:24348373

  2. Measuring Grip Pressure during the Golf Swing.

    ERIC Educational Resources Information Center

    Budney, David R.

    1979-01-01

    With the use of a special instrumented golf club, grip pressure measurements can be used by the instructor to quantify and discuss the effects of grip pressure in relation to instructional points. (MM)

  3. Use of reduction rate as a quantitative knob for controlling the twin structure and shape of palladium nanocrystals.

    PubMed

    Wang, Yi; Peng, Hsin-Chieh; Liu, Jingyue; Huang, Cheng Zhi; Xia, Younan

    2015-02-11

    Kinetic control is a powerful means for maneuvering the twin structure and shape of metal nanocrystals and thus optimizing their performance in a variety of applications. However, there is only a vague understanding of the explicit roles played by reaction kinetics due to the lack of quantitative information about the kinetic parameters. With Pd as an example, here we demonstrate that kinetic parameters, including rate constant and activation energy, can be derived from spectroscopic measurements and then used to calculate the initial reduction rate and further have this parameter quantitatively correlated with the twin structure of a seed and nanocrystal. On a quantitative basis, we were able to determine the ranges of initial reduction rates required for the formation of nanocrystals with a specific twin structure, including single-crystal, multiply twinned, and stacking fault-lined. This work represents a major step forward toward the deterministic syntheses of colloidal noble-metal nanocrystals with specific twin structures and shapes.

  4. Systems and Methods for Gravity-Independent Gripping and Drilling

    NASA Technical Reports Server (NTRS)

    Thatte, Nitish (Inventor); King, Jonathan P. (Inventor); Parness, Aaron (Inventor); Frost, Matthew A. (Inventor)

    2016-01-01

    Systems and methods for gravity independent gripping and drilling are described. The gripping device can also comprise a drill or sampling devices for drilling and/or sampling in microgravity environments, or on vertical or inverted surfaces in environments where gravity is present. A robotic system can be connected with the gripping and drilling devices via an ankle interface adapted to distribute the forces realized from the robotic system.

  5. Hand grip strength and associated factors in non-institutionalised men and women 50 years and older in South Africa.

    PubMed

    Ramlagan, Shandir; Peltzer, Karl; Phaswana-Mafuya, Nancy

    2014-01-07

    Little is known about the prevalence, predictors and gender differences in hand grip strength of older adults in Africa. This study aims to investigate social and health differences in hand grip strength among older adults in a national probability sample of older South Africans who participated in the Study of Global Ageing and Adults Health (SAGE wave 1) in 2008. We conducted a national population-based cross-sectional study with a sample of 3840 men and women aged 50 years or older in South Africa. The questionnaire included socio-demographic characteristics, health variables, and anthropometric measurements. Linear multivariate regression analysis was performed to assess the association of social factors, health variables and grip strength. The mean overall hand grip strength was 37.9 kgs for men (mean age 61.1 years, SD = 9.1) and 31.5 kgs for women (mean age 62.0 years, SD = 9.7). In multivariate analysis among men, greater height, not being underweight and lower functional disability was associated with greater grip strength, and among women, greater height, better cognitive functioning, and lower functional disability were associated with greater grip strength. Greater height and lower functional disability were found for both older South African men and women to be significantly associated with grip strength.

  6. Using Hand Grip Force as a Correlate of Longitudinal Acceleration Comfort for Rapid Transit Trains

    PubMed Central

    Guo, Beiyuan; Gan, Weide; Fang, Weining

    2015-01-01

    Longitudinal acceleration comfort is one of the essential metrics used to evaluate the ride comfort of train. The aim of this study was to investigate the effectiveness of using hand grip force as a correlate of longitudinal acceleration comfort of rapid transit trains. In the paper, a motion simulation system was set up and a two-stage experiment was designed to investigate the role of the grip force on the longitudinal comfort of rapid transit trains. The results of the experiment show that the incremental grip force was linearly correlated with the longitudinal acceleration value, while the incremental grip force had no correlation with the direction of the longitudinal acceleration vector. The results also show that the effects of incremental grip force and acceleration duration on the longitudinal comfort of rapid transit trains were significant. Based on multiple regression analysis, a step function model was established to predict the longitudinal comfort of rapid transit trains using the incremental grip force and the acceleration duration. The feasibility and practicably of the model was verified by a field test. Furthermore, a comparative analysis shows that the motion simulation system and the grip force based model were valid to support the laboratory studies on the longitudinal comfort of rapid transit trains. PMID:26147730

  7. Differences in grip force control between young and late middle-aged adults.

    PubMed

    Zheng, Lianrong; Li, Kunyang; Wang, Qian; Chen, Wenhui; Song, Rong; Liu, Guanzheng

    2017-09-01

    Grip force control is a crucial function for human to guarantee the quality of life. To examine the effects of age on grip force control, 10 young adults and 11 late middle-aged adults participated in visually guided tracking tasks using different target force levels (25, 50, and 75% of the subject's maximal grip force). Multiple measures were used to evaluate the tracking performance during force rising phase and force maintenance phase. The measurements include the rise time, fuzzy entropy, mean force percentage, coefficient of variation, and target deviation ratio. The results show that the maximal grip force was significantly lower in the late middle-aged adults than in the young adults. The time of rising phase was systematically longer among late middle-aged adults. The fuzzy entropy is a useful indicator for quantitating the force variability of the grip force signal at higher force levels. These results suggest that the late middle-aged adults applied a compensatory strategy that allow allows for sufficient time to reach the required grip force and reduce the impact of the early and subtle degenerative changes in hand motor function.

  8. Control of finger forces during fast, slow and moderate rotational hand movements.

    PubMed

    Kazemi, Hamed; Kearney, Robert E; Milner, Theodore E

    2014-01-01

    The goal of this study was to investigate the effect of speed on patterns of grip forces during twisting movement involving forearm supination against a torsional load (combined elastic and inertial load). For slow and moderate speed rotations, the grip force increased linearly with load torque. However, for fast rotations in which the contribution of the inertia to load torque was significantly greater than slower movements, the grip force-load torque relationship could be segmented into two phases: a linear ascending phase corresponding to the acceleration part of the movement followed by a plateau during deceleration. That is, during the acceleration phase, the grip force accurately tracked the combined elastic and inertial load. However, the coupling between grip force and load torque was not consistent during the deceleration phase of the movement. In addition, as speed increased, both the position and the force profiles became smoother. No differences in the baseline grip force, safety margin to secure the grasp during hold phase or the overall change in grip force were observed across different speeds.

  9. Integration of a computerized two-finger gripper for robot workstation safety

    NASA Technical Reports Server (NTRS)

    Sneckenberger, John E.; Yoshikata, Kazuki

    1988-01-01

    A microprocessor-based controller has been developed that continuously monitors and adjusts the gripping force applied by a special two-finger gripper. This computerized force sensing gripper system enables the endeffector gripping action to be independently detected and corrected. The gripping force applied to a manipulated object is real-time monitored for problem situations, situations which can occur during both planned and errant robot arm manipulation. When unspecified force conditions occur at the gripper, the gripping force controller initiates specific reactions to cause dynamic corrections to the continuously variable gripping action. The force controller for this intelligent gripper has been interfaced to the controller of an industrial robot. The gripper and robot controllers communicate to accomplish the successful completion of normal gripper operations as well as unexpected hazardous situations. An example of an unexpected gripping condition would be the sudden deformation of the object being manipulated by the robot. The capabilities of the interfaced gripper-robot system to apply workstation safety measures (e.g., stop the robot) when these unexpected gripping effects occur have been assessed.

  10. Effects of EVA gloves on grip strength and fatigue under low temperature and low pressure.

    PubMed

    Tian, Yinsheng; Ding, Li; Liu, Heqing; Li, Yan; Li, Deyu; Wang, Li

    2016-03-01

    To study the effects of wearing extravehicular activity (EVA) gloves on grip strength and fatigue in low temperature, low pressure and mixing of two factors (low temperature and low pressure). The maximum grip strength and fatigue tests were performed with 10 healthy male subjects wearing gloves in a variety of simulated environments. The data was analysed using the normalization method. The results showed that wearing gloves significantly affected the maximum grip strength and fatigue. Pressure (29.6, 39.2 kPa) had more influence on the maximum grip compared with control group while low temperatures (-50, -90, -110 °C) had no influence on grip but affected fatigue dramatically. The results also showed that the maximum grip strength and fatigue were influenced significantly in a compound environment. Space environment remarkably reduced strength and endurance of the astronauts. However, the effects brought by the compound environment cannot be understood as the superimposition of low temperature and pressure effects. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  11. 23. POWELLTYPE CAR THROUGH GRIP REMOVAL DOOR: View looking through ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. POWELL-TYPE CAR THROUGH GRIP REMOVAL DOOR: View looking through grip removal door into interior of a Powell-type cable car. - San Francisco Cable Railway, Washington & Mason Streets, San Francisco, San Francisco County, CA

  12. Alterations in grip strength during male sexual arousal.

    PubMed

    Jiao, C; Turman, B; Weerakoon, P; Knight, P

    2006-01-01

    Although it is known that alterations in grip strength occur under a number of conditions, little is known about relationships between grip strength and sexual arousal. This relationship was investigated in 30 healthy heterosexual males, who viewed both erotic and nonerotic videos. A questionnaire was used to assess the extent of sexual arousal. The grip strengths of both hands were measured with a five-position (P1-P5) dynamometer, before and after watching the videos. After watching the erotic video, there was a statistically significant reduction in grip strength for the P2 position, with nonsignificant overall reductions in grip strength for all other positions tested. No such effect was observed in control tests. The results indicate that during sexual arousal, the neural system is likely to reduce the output to muscles not directly related to sexual function, presumably to enhance the physiological responses of sexual arousal.

  13. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment.

    PubMed

    Filteau, S; PrayGod, G; Woodd, S L; Friis, H; Heimburger, D C; Koethe, J R; Kelly, P; Kasonka, L; Rehman, A M

    2017-10-01

    Low grip strength is a marker of frailty and a risk factor for mortality among HIV patients and other populations. We investigated factors associated with grip strength in malnourished HIV patients at referral to ART, and at 12 weeks and 2-3 years after starting ART. The study involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index <18.5 kg/m 2 ) and requiring ART. The relationship of grip strength to nutritional, infectious and demographic factors was assessed by multivariable linear regression at referral for ART (n = 1742) and after 12 weeks (n = 778) and 2-3 years of ART (n = 273). In analyses controlled only for sex, age and height, most nutrition and infection-related variables were associated with grip strength. However, in multivariable analyses, consistent associations were seen for fat-free mass index, mid-upper arm circumference, haemoglobin and systolic blood pressure, and a variable association with fat mass index in men. C-reactive protein and CD4 count had limited independent effects on grip strength, while receiving tuberculosis treatment was associated with weaker grip strength. In this population of originally malnourished HIV patients, poor grip strength was more strongly and independently associated with nutritional than with infection and inflammation variables. Programmes to improve health and survival of HIV patients should incorporate nutritional assessment and management and could use grip strength as a functional indicator of improving nutrition. © 2017 John Wiley & Sons Ltd.

  14. The Association of Levels of and Decline in Grip Strength in Old Age with Trajectories of Life Course Occupational Position.

    PubMed

    Kröger, Hannes; Fritzell, Johan; Hoffmann, Rasmus

    2016-01-01

    The study of the influence of life course occupational position (OP) on health in old age demands analysis of time patterns in both OP and health. We study associations between life course time patterns of OP and decline in grip strength in old age. We analyze 5 waves from the Survey of Health Ageing and Retirement in Europe (n = 5108, ages 65-90). We use a pattern-mixture latent growth model to predict the level and decline in grip strength in old age by trajectory of life course OP. We extend and generalize the structured regression approach to establish the explanatory power of different life course models for both the level and decline of grip strength. Grip strength declined linearly by 0.70 kg (95% CI -0.74;-0.66) for men and 0.42 kg (95% CI -0.45;-0.39) for women per year. The level of men's grip strength can best be explained by a critical period during midlife, with those exposed to low OP during this period having 1.67 kg (95% CI -2.33;-1.00) less grip strength. These differences remain constant over age. For women, no association between OP and levels of or decline in grip strength was found. Men's OP in midlife seems to be a critical period for the level of grip strength in old age. Inequalities remain constant over age. The integration of the structured regression approach and latent growth modelling offers new possibilities for life course epidemiology.

  15. Factors associated with grip strength decline in older adults.

    PubMed

    Sternäng, Ola; Reynolds, Chandra A; Finkel, Deborah; Ernsth-Bravell, Marie; Pedersen, Nancy L; Dahl Aslan, Anna K

    2015-03-01

    Few studies have examined associations of multi-faceted demographic, health and lifestyle factors with long-term change in grip strength performance across the adult lifespan. The aim of this study was to examine the associations of risk factors in specific parts of the adult lifespan (e.g. in early midlife, in late midlife and in old adulthood) separately for women and men. Data came from the longitudinal Swedish Adoption/Twin Study of Aging (SATSA). Grip strength performance was followed in 849 participants who were 50-88 years of age at baseline. The follow-up period with seven waves of data of grip strength was 22 years, and the risk factors were measured up to 20 years before the assessment of grip strength. Latent growth modelling was used for the longitudinal analyses. A gender difference in the type of factors associated with grip strength performance and development across the adult lifespan was found. Significant factors for the age slopes for women were stress, smoking and dementia. For men, marital status, mean arterial pressure, physical activity at work and having a chronic disorder were of importance. These factors varied in their associations with grip strength across the adult lifespan. Factors measured earlier in adulthood were associated with grip strength decline in late midlife and old adulthood. Gender-specific patterns of risk factors suggest that it may be worthwhile to conduct research on grip and muscle strength (and biological vitality) separately for men and women. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Shape-Controlled Synthesis of Colloidal Metal Nanocrystals: Thermodynamic versus Kinetic Products.

    PubMed

    Xia, Younan; Xia, Xiaohu; Peng, Hsin-Chieh

    2015-07-01

    This Perspective provides a contemporary understanding of the shape evolution of colloidal metal nanocrystals under thermodynamically and kinetically controlled conditions. It has been extremely challenging to investigate this subject in the setting of one-pot synthesis because both the type and number of seeds involved would be changed whenever the experimental conditions are altered, making it essentially impossible to draw conclusions when comparing the outcomes of two syntheses conducted under different conditions. Because of the uncertainty about seeds, most of the mechanistic insights reported in literature for one-pot syntheses of metal nanocrystals with different shapes are either incomplete or ambiguous, and some of them might be misleading or even wrong. Recently, with the use of well-defined seeds for such syntheses, it became possible to separate growth from nucleation and therefore investigate the explicit role(s) played by a specific thermodynamic or kinetic parameter in directing the evolution of colloidal metal nanocrystals into a specific shape. Starting from single-crystal seeds enclosed by a mix of {100}, {111}, and {110} facets, for example, one can obtain colloidal nanocrystals with diversified shapes by adjusting various thermodynamic or kinetic parameters. The mechanistic insights learnt from these studies can also be extended to account for the products of conventional one-pot syntheses that involve self-nucleation only. The knowledge can be further applied to many other types of seeds with twin defects or stacking faults, making it an exciting time to design and synthesize colloidal metal nanocrystals with the shapes sought for a variety of fundamental studies and technologically important applications.

  17. Hand grip strength and associated factors in non-institutionalised men and women 50 years and older in South Africa

    PubMed Central

    2014-01-01

    Background Little is known about the prevalence, predictors and gender differences in hand grip strength of older adults in Africa. This study aims to investigate social and health differences in hand grip strength among older adults in a national probability sample of older South Africans who participated in the Study of Global Ageing and Adults Health (SAGE wave 1) in 2008. Methods We conducted a national population-based cross-sectional study with a sample of 3840 men and women aged 50 years or older in South Africa. The questionnaire included socio-demographic characteristics, health variables, and anthropometric measurements. Linear multivariate regression analysis was performed to assess the association of social factors, health variables and grip strength. Results The mean overall hand grip strength was 37.9 kgs for men (mean age 61.1 years, SD = 9.1) and 31.5 kgs for women (mean age 62.0 years, SD = 9.7). In multivariate analysis among men, greater height, not being underweight and lower functional disability was associated with greater grip strength, and among women, greater height, better cognitive functioning, and lower functional disability were associated with greater grip strength. Conclusions Greater height and lower functional disability were found for both older South African men and women to be significantly associated with grip strength. PMID:24393403

  18. Age-related normative values for handgrip strength and grip strength’s usefulness as a predictor of mortality and both cognitive and physical decline in older adults in northwest Russia

    PubMed Central

    Turusheva, A.; Frolova, E.; Degryse, J-M.

    2017-01-01

    Objectives: This paper sought to provide normative values for grip strength among older adults across different age groups in northwest Russia and to investigate their predictive value for adverse events. Methods: A population-based prospective cohort study of 611 community-dwelling individuals 65+. Grip strength was measured using the standard protocol applied in the Groningen Elderly Tests. The cut-off thresholds for grip strength were defined separately for men and women of different ages using a weighted polynomial regression. A Cox regression analysis, the c-statistic, a risk reclassification analysis, and bootstrapping techniques were used to analyze the data. The outcomes were the 5-year mortality rate, the loss of autonomy and mental decline. Results: We determined the age-related reference intervals of grip strength for older adults. The 5th and 10th percentiles of grip strength were associated with a higher risk for malnutrition, low autonomy, physical and mental functioning and 5-year mortality. The 5th percentile of grip strength was associated with a decline in autonomy. Conclusions: This study presents age- and sex-specific reference values for grip strength in the 65+ Russian population derived from a prospective cohort study. The norms can be used in clinical practice to identify patients at increased risk for adverse outcomes. PMID:28250246

  19. Femtosecond laser pulse driven melting in gold nanorod aqueous colloidal suspension: Identification of a transition from stretched to exponential kinetics

    DOE PAGES

    Li, Yuelin; Jiang, Zhang; Lin, Xiao -Min; ...

    2015-01-30

    Many potential industrial, medical, and environmental applications of metal nanorods rely on the physics and resultant kinetics and dynamics of the interaction of these particles with light. We report a surprising kinetics transition in the global melting of femtosecond laser-driven gold nanorod aqueous colloidal suspension. At low laser intensity, the melting exhibits a stretched exponential kinetics, which abruptly transforms into a compressed exponential kinetics when the laser intensity is raised. It is found the relative formation and reduction rate of intermediate shapes play a key role in the transition. Supported by both molecular dynamics simulations and a kinetic model, themore » behavior is traced back to the persistent heterogeneous nature of the shape dependence of the energy uptake, dissipation and melting of individual nanoparticles. These results could have significant implications for various applications such as water purification and electrolytes for energy storage that involve heat transport between metal nanorod ensembles and surrounding solvents.« less

  20. Proandrogenic and Antiandrogenic Progestins in Transgender Youth: Differential Effects on Body Composition and Bone Metabolism.

    PubMed

    Tack, Lloyd J W; Craen, Margarita; Lapauw, Bruno; Goemaere, Stefan; Toye, Kaatje; Kaufman, Jean-Marc; Vandewalle, Sara; T'Sjoen, Guy; Zmierczak, Hans-Georg; Cools, Martine

    2018-06-01

    Progestins can be used to attenuate endogenous hormonal effects in late-pubertal transgender (trans) adolescents (Tanner stage B4/5 and G4/5). Currently, no data are available on the effects of progestins on the development of bone mass or body composition in trans youth. To study prospectively the evolution of body composition and bone mass in late-pubertal trans adolescents using the proandrogenic or antiandrogenic progestins lynestrenol (L) and cyproterone acetate (CA), respectively. Forty-four trans boys (Tanner B4/5) and 21 trans girls (Tanner G4/5) were treated with L or CA for 11.6 (4 to 40) and 10.6 (5 to 31) months, respectively. Anthropometry, grip strength, body composition, and bone mass, size, and density were determined by dual-energy X-ray absorptiometry and peripheral quantitative computed tomography before the start of progestin and before addition of cross-sex hormones. Using L, lean mass [+3.2 kg (8.6%)] and grip strength [+3 kg (10.6%)] significantly increased, which coincided with a more masculine body shape in trans boys. Trans girls showed loss of lean mass [-2.2 kg (4.7%)], gain of fat mass [+1.5 kg (9.4%)], and decreased grip strength Z scores. CA limited normal bone expansion and impeded pubertal bone mass accrual, mostly at the lumbar spine [Z score: -0.765 to -1.145 (P = 0.002)]. L did not affect physiological bone development. Proandrogenic and antiandrogenic progestins induce body composition changes in line with the desired appearance within 1 year of treatment. Bone health, especially at the lumbar spine, is of concern in trans girls, as bone mass accrual is severely affected by androgen suppressive therapy.

  1. Grip Force Adjustments Reflect Prediction of Dynamic Consequences in Varying Gravitoinertial Fields

    PubMed Central

    White, Olivier; Thonnard, Jean-Louis; Lefèvre, Philippe; Hermsdörfer, Joachim

    2018-01-01

    Humans have a remarkable ability to adjust the way they manipulate tools through a genuine regulation of grip force according to the task. However, rapid changes in the dynamical context may challenge this skill, as shown in many experimental approaches. Most experiments adopt perturbation paradigms that affect only one sensory modality. We hypothesize that very fast adaptation can occur if coherent information from multiple sensory modalities is provided to the central nervous system. Here, we test whether participants can switch between different and never experienced dynamical environments induced by centrifugation of the body. Seven participants lifted an object four times in a row successively in 1, 1.5, 2, 2.5, 2, 1.5, and 1 g. We continuously measured grip force, load force and the gravitoinertial acceleration that was aligned with body axis (perceived gravity). Participants adopted stereotyped grasping movements immediately upon entry in a new environment and needed only one trial to adapt grip forces to a stable performance in each new gravity environment. This result was underlined by good correlations between grip and load forces in the first trial. Participants predictively applied larger grip forces when they expected increasing gravity steps. They also decreased grip force when they expected decreasing gravity steps, but not as much as they could, indicating imperfect anticipation in that condition. The participants' performance could rather be explained by a combination of successful scaling of grip force according to gravity changes and a separate safety factor. The data suggest that in highly unfamiliar dynamic environments, grip force regulation is characterized by a combination of a successful anticipation of the experienced environmental condition, a safety factor reflecting strategic response to uncertainties about the environment and rapid feedback mechanisms to optimize performance under constant conditions. PMID:29527176

  2. The role of tactile feedback in grip force during laparoscopic training tasks.

    PubMed

    Wottawa, Christopher R; Cohen, Jeremiah R; Fan, Richard E; Bisley, James W; Culjat, Martin O; Grundfest, Warren S; Dutson, Erik P

    2013-04-01

    Laparoscopic minimally invasive surgery has revolutionized surgical care by reducing trauma to the patient, thereby decreasing the need for medication and shortening recovery times. During open procedures, surgeons can directly feel tissue characteristics. However, in laparoscopic surgery, tactile feedback during grip is attenuated and limited to the resistance felt in the tool handle. Excessive grip force during laparoscopic surgery can lead to tissue damage. Providing additional supplementary tactile feedback may allow subjects to have better control of grip force and identification of tissue characteristics, potentially decreasing the learning curve associated with complex minimally invasive techniques. A tactile feedback system has been developed and integrated into a modified laparoscopic grasper that allows forces applied at the grasper tips to be felt by the surgeon's hands. In this study, 15 subjects (11 novices, 4 experts) were asked to perform single-handed peg transfers using these laparoscopic graspers in three trials (feedback OFF, ON, OFF). Peak and average grip forces (newtons) during each grip event were measured and compared using a Wilcoxon ranked test in which each subject served as his or her own control. After activating the tactile feedback system, the novice subject population showed significant decreases in grip force (p < 0.003). When the system was deactivated for the third trial, there were significant increases in grip force (p < 0.003). Expert subjects showed no significant improvements with the addition of tactile feedback (p > 0.05 in all cases). Supplementary tactile feedback helped novice subjects reduce grip force during the laparoscopic training task but did not offer improvements for the four expert subjects. This indicates that tactile feedback may be beneficial for laparoscopic training but has limited long-term use in the nonrobotic setting.

  3. Hand grip strength and dexterity function in children aged 6-12 years: A cross-sectional study.

    PubMed

    Omar, Mohammed T A; Alghadir, Ahmad H; Zafar, Hamayun; Al Baker, Shaheerah

    Cross-sectional and clinical measurement. Assessment of hand function considers an essential part in clinical practice. To develop normative values of hand grip strength and dexterity function for 6-12-year-old children in Saudi Arabia. Grip strength and dexterity function was measured in 525 children using Grip Track hand dynamometer (JTECH Medical, Midvale, UT, USA) and 9-hole pegboard test respectively. The grip strength and dexterity function was improved as age progressed regardless of gender. Across all age groups, the hand grip strength of boys was significantly higher than girls for dominant hand (31.75 ± 10.33 vs 28.24 ± 9.35; P < .001) and nondominant hand (31.01 ± 10.27 vs 27.27 ± 9.30; P < .001). The girls performed slightly faster than boys for dominant hand (19.70 vs 20.68; P < .05) and nondominant hand (21.79 vs 23.46; P < .05). In general, girls completed a 9-HPT faster than boys in the 2 of 7 age groups: 11 years (9-HPT scores = 2.10 seconds; P < .01) and 12 years (9-HPT scores = 1.93 seconds; P < .01). The overall patterns of hand grip strength and dexterity function observed in the present study are similar to the previous studies that established acceleration of grip strength with advanced age, and faster performance scores in older children than younger children in both genders. Norms of hand grip strength and dexterity enable therapists to identify some developmental characteristics of hand function among Saudi children, determine the presence of impairment, and compare scores from children in different clinical settings. Not applicable. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  4. The effect of grip force, stroke rotation and frequency on discomfort for a torqueing tasks.

    PubMed

    Bano, Farheen; Mallick, Zulqernian; Khan, Abid Ali

    2015-08-08

    Occupational tasks involve awkward upper limb postures, especially movement of forearm with repetitive combined gripping and torqueing exertions, which may lead to development of WMSDs. From the literature survey it was observed that there was a lack of studies focussed on the combined effect of torque and grip exertions on forearm discomfort. The present study was to investigate the effects of grip force, stroke rotation and frequency of exertions on discomfort and Electromyography (EMG) activities of the forearm muscles in a repetitive torqueing task. Twenty-seven male participants volunteered in this study. The participants performed repetitive exertions for a 5 minutes duration for each combination of the different levels of stroke rotation, grip force and frequency of exertions. Three levels of stroke rotation, three levels of grip force and three levels of frequency of exertion were chosen as independent variables. Therefore a 3 × 3 customized factorial design was used for the experiment for each level of grip force. Hence, the study was divided into three groups on the basis of grip force (50N, 70N and 90N). The ANOVA showed that stroke rotation and frequency of exertion were significant on discomfort. Further Students Newmann test (SNK) revealed that discomfort was increased with increasing stroke rotation and frequency of exertion. The multivariate analysis of variances (MANOVA) performed on EMG data instead of ANOVA because EMG activities of five muscles simultaneously were recorded. The Results found that extensor muscles were more fatigued in torqueing with gripping task. It was found that stroke rotation for the torqueing tasks must be kept below 45°. It was concluded that it is important to control stroke rotation to improve performance of repetitive torqueing activity.

  5. Adjustment of gripping force by optical systems

    NASA Astrophysics Data System (ADS)

    Jalba, C. K.; Barz, C.

    2018-01-01

    With increasing automation, robotics also requires ever more intelligent solutions in the handling of various tasks. In this context, many grippers must also be re-designed. For this, they must always be adapted for different requirements. The equipment of the gripper systems with sensors should help to make the gripping process more intelligent. In order to achieve such objectives, optical systems can also be used. This work analyzes how the gripping force can be adjusted by means of an optical recognition. The result of this work is the creation of a connection between optical recognition, tolerances, gripping force and real-time control. In this way, algorithms can be created, with the aid of which robot grippers as well as other gripping systems become more intelligent.

  6. Novel fiber optic sensor for grip testing

    NASA Astrophysics Data System (ADS)

    Zhao, Li Ping; Fang, Zhong Ping; Paul, Jinu; Ngoi, Bryan K. A.; Ng, Jun Hong

    2004-12-01

    Grip strength is an easy measure of skeletal muscle function as well as a powerful predictor of disability, morbidity and mortality. In order to measure the grip strength, a novel fiber optic approach is proposed and demonstrated. Strain dependent wavelength response of fiber Bragg gratings (FBGs) has been utilized to obtain the strength of individual fingers. Five FBGs are written at different center wavelengths on a single photosensitive fiber. Each FBG is used to get the response from each individual finger. The fiber containing the gratings is attached to a suitable grip holder, which can effectively transfer the grip force to the FBGs. An additional reference FBG is also provided to make the device temperature insensitive. Experimental results show that the wavelength shifts of the order of 0.2-0.5 nm can be achieved for individual fingers. The device is calibrated in terms of load to convert the wavelength shift to the strength of the grip. The time dependent wavelength fluctuations was also studied and presented in this paper.

  7. Evaluation of four steering wheels to determine driver hand placement in a static environment.

    PubMed

    Mossey, Mary E; Xi, Yubin; McConomy, Shayne K; Brooks, Johnell O; Rosopa, Patrick J; Venhovens, Paul J

    2014-07-01

    While much research exists on occupant packaging both proprietary and in the literature, more detailed research regarding user preferences for subjective ratings of steering wheel designs is sparse in published literature. This study aimed to explore the driver interactions with production steering wheels in four vehicles by using anthropometric data, driver hand placement, and driver grip design preferences for Generation-Y and Baby Boomers. In this study, participants selected their preferred grip diameter, responded to a series of questions about the steering wheel grip as they sat in four vehicles, and rank ordered their preferred grip design. Thirty-two male participants (16 Baby Boomers between ages 47 and 65 and 16 Generation-Y between ages 18 and 29) participated in the study. Drivers demonstrated different gripping behavior between vehicles and between groups. Recommendations for future work in steering wheel grip design and naturalistic driver hand positioning are discussed. Copyright © 2014. Published by Elsevier Ltd.

  8. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness.

    PubMed

    Willems, Sara M; Wright, Daniel J; Day, Felix R; Trajanoska, Katerina; Joshi, Peter K; Morris, John A; Matteini, Amy M; Garton, Fleur C; Grarup, Niels; Oskolkov, Nikolay; Thalamuthu, Anbupalam; Mangino, Massimo; Liu, Jun; Demirkan, Ayse; Lek, Monkol; Xu, Liwen; Wang, Guan; Oldmeadow, Christopher; Gaulton, Kyle J; Lotta, Luca A; Miyamoto-Mikami, Eri; Rivas, Manuel A; White, Tom; Loh, Po-Ru; Aadahl, Mette; Amin, Najaf; Attia, John R; Austin, Krista; Benyamin, Beben; Brage, Søren; Cheng, Yu-Ching; Cięszczyk, Paweł; Derave, Wim; Eriksson, Karl-Fredrik; Eynon, Nir; Linneberg, Allan; Lucia, Alejandro; Massidda, Myosotis; Mitchell, Braxton D; Miyachi, Motohiko; Murakami, Haruka; Padmanabhan, Sandosh; Pandey, Ashutosh; Papadimitriou, Ioannis; Rajpal, Deepak K; Sale, Craig; Schnurr, Theresia M; Sessa, Francesco; Shrine, Nick; Tobin, Martin D; Varley, Ian; Wain, Louise V; Wray, Naomi R; Lindgren, Cecilia M; MacArthur, Daniel G; Waterworth, Dawn M; McCarthy, Mark I; Pedersen, Oluf; Khaw, Kay-Tee; Kiel, Douglas P; Pitsiladis, Yannis; Fuku, Noriyuki; Franks, Paul W; North, Kathryn N; van Duijn, Cornelia M; Mather, Karen A; Hansen, Torben; Hansson, Ola; Spector, Tim; Murabito, Joanne M; Richards, J Brent; Rivadeneira, Fernando; Langenberg, Claudia; Perry, John R B; Wareham, Nick J; Scott, Robert A

    2017-07-12

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of 195,180 individuals and identify 16 loci associated with grip strength (P<5 × 10 -8 ) in combined analyses. A number of these loci contain genes implicated in structure and function of skeletal muscle fibres (ACTG1), neuronal maintenance and signal transduction (PEX14, TGFA, SYT1), or monogenic syndromes with involvement of psychomotor impairment (PEX14, LRPPRC and KANSL1). Mendelian randomization analyses are consistent with a causal effect of higher genetically predicted grip strength on lower fracture risk. In conclusion, our findings provide new biological insight into the mechanistic underpinnings of grip strength and the causal role of muscular strength in age-related morbidities and mortality.

  9. Decoding gripping force based on local field potentials recorded from subthalamic nucleus in humans

    PubMed Central

    Tan, Huiling; Pogosyan, Alek; Ashkan, Keyoumars; Green, Alexander L; Aziz, Tipu; Foltynie, Thomas; Limousin, Patricia; Zrinzo, Ludvic; Hariz, Marwan; Brown, Peter

    2016-01-01

    The basal ganglia are known to be involved in the planning, execution and control of gripping force and movement vigour. Here we aim to define the nature of the basal ganglia control signal for force and to decode gripping force based on local field potential (LFP) activities recorded from the subthalamic nucleus (STN) in patients with deep brain stimulation (DBS) electrodes. We found that STN LFP activities in the gamma (55–90 Hz) and beta (13–30m Hz) bands were most informative about gripping force, and that a first order dynamic linear model with these STN LFP features as inputs can be used to decode the temporal profile of gripping force. Our results enhance the understanding of how the basal ganglia control gripping force, and also suggest that deep brain LFPs could potentially be used to decode movement parameters related to force and movement vigour for the development of advanced human-machine interfaces. DOI: http://dx.doi.org/10.7554/eLife.19089.001 PMID:27855780

  10. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis.

    PubMed

    Schaefer, Sydney Y; DeJong, Stacey L; Cherry, Kendra M; Lang, Catherine E

    2012-04-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in poststroke hemiparesis. Sixteen adults with poststroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared with the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment.

  11. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis

    PubMed Central

    Schaefer, Sydney Y.; DeJong, Stacey L.; Cherry, Kendra M.; Lang, Catherine E.

    2011-01-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in post-stroke hemiparesis. Sixteen adults with post-stroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared to the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment. PMID:22357103

  12. A Three-Dimensional Kinematic and Kinetic Study of the College-Level Female Softball Swing

    PubMed Central

    Milanovich, Monica; Nesbit, Steven M.

    2014-01-01

    This paper quantifies and discusses the three-dimensional kinematic and kinetic characteristics of the female softball swing as performed by fourteen female collegiate amateur subjects. The analyses were performed using a three-dimensional computer model. The model was driven kinematically from subject swings data that were recorded with a multi-camera motion analysis system. Each subject used two distinct bats with significantly different inertial properties. Model output included bat trajectories, subject/bat interaction forces and torques, work, and power. These data formed the basis for a detailed analysis and description of fundamental swing kinematic and kinetic quantities. The analyses revealed that the softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. In addition, the potential effects of bat properties on swing mechanics are discussed. The paths of the hands and the centre-of-curvature of the bat relative to the horizontal plane appear to be important trajectory characteristics of the swing. Descriptions of the swing mechanics and practical implications are offered based upon these findings. Key Points The female softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. The paths of the grip point, bat centre-of-curvature, CG, and COP are complex yet reveal consistent patterns among subjects indicating that these patterns are fundamental components of the swing. The most important mechanical quantity relative to generating bat speed is the total work applied to the bat from the batter. Computer modeling of the softball swing is a viable means for study of the fundamental mechanics of the swing motion, the interactions between the batter and the bat, and the energy transfers between the two. PMID:24570623

  13. A three-dimensional kinematic and kinetic study of the college-level female softball swing.

    PubMed

    Milanovich, Monica; Nesbit, Steven M

    2014-01-01

    This paper quantifies and discusses the three-dimensional kinematic and kinetic characteristics of the female softball swing as performed by fourteen female collegiate amateur subjects. The analyses were performed using a three-dimensional computer model. The model was driven kinematically from subject swings data that were recorded with a multi-camera motion analysis system. Each subject used two distinct bats with significantly different inertial properties. Model output included bat trajectories, subject/bat interaction forces and torques, work, and power. These data formed the basis for a detailed analysis and description of fundamental swing kinematic and kinetic quantities. The analyses revealed that the softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. In addition, the potential effects of bat properties on swing mechanics are discussed. The paths of the hands and the centre-of-curvature of the bat relative to the horizontal plane appear to be important trajectory characteristics of the swing. Descriptions of the swing mechanics and practical implications are offered based upon these findings. Key PointsThe female softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities.The paths of the grip point, bat centre-of-curvature, CG, and COP are complex yet reveal consistent patterns among subjects indicating that these patterns are fundamental components of the swing.The most important mechanical quantity relative to generating bat speed is the total work applied to the bat from the batter.Computer modeling of the softball swing is a viable means for study of the fundamental mechanics of the swing motion, the interactions between the batter and the bat, and the energy transfers between the two.

  14. Evidence for cluster shape effects on the kinetic energy spectrum in thermionic emission.

    PubMed

    Calvo, F; Lépine, F; Baguenard, B; Pagliarulo, F; Concina, B; Bordas, C; Parneix, P

    2007-11-28

    Experimental kinetic energy release distributions obtained for the thermionic emission from C(n) (-) clusters, 10< or =n< or =20, exhibit significant non-Boltzmann variations. Using phase space theory, these different features are analyzed and interpreted as the consequence of contrasting shapes in the daughter clusters; linear and nonlinear isomers have clearly distinct signatures. These results provide a novel indirect structural probe for atomic clusters associated with their thermionic emission spectra.

  15. Relationship Between Muscle Strength Asymmetry and Body Sway in Older Adults.

    PubMed

    Koda, Hitoshi; Kai, Yoshihiro; Murata, Shin; Osugi, Hironori; Anami, Kunihiko; Fukumoto, Takahiko; Imagita, Hidetaka

    2018-05-31

    The purpose of this study was to investigate the relationship between muscle strength asymmetry and body sway while walking. We studied 63 older adult women. Strong side and weak side of knee extension strength, toe grip strength, hand grip strength, and body sway while walking were measured. The relationship between muscle strength asymmetry for each muscle and body sway while walking was evaluated using Pearson's correlation coefficient. Regarding the muscles recognized to have significant correlation with body sway, the asymmetry cutoff value causing an increased sway was calculated. Toe grip strength asymmetry was significantly correlated with body sway. Toe grip strength asymmetry causing an increased body sway had a cutoff value of 23.5%. Our findings suggest toe grip strength asymmetry may be a target for improving gait stability.

  16. The effects of grip width on sticking region in bench press.

    PubMed

    Gomo, Olav; Van Den Tillaar, Roland

    2016-01-01

    The aim of this study was to examine the occurrence of the sticking region by examining how three different grip widths affect the sticking region in powerlifters' bench press performance. It was hypothesised that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width, indicating a poor mechanical region for vertical force production at these joint angles. Twelve male experienced powerlifters (age 27.7 ± 8.8 years, mass 91.9 ± 15.4 kg) were tested in one repetition maximum (1-RM) bench press with a narrow, medium and wide grip. Joint kinematics, timing, bar position and velocity were measured with a 3D motion capture system. All participants showed a clear sticking region with all three grip widths, but this sticking region was not found to occur at the same joint angles in all three grip widths, thereby rejecting the hypothesis that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width. It is suggested that, due to the differences in moment arm of the barbell about the elbow joint in the sticking region, there still might be a poor mechanical region for total force production that is joint angle-specific.

  17. Association between dietary protein intake and grip strength among adults aged 51 years and over: What We Eat in America, National Health and Nutrition Examination Survey 2011-2014.

    PubMed

    Mishra, Suruchi; Goldman, Joseph D; Sahyoun, Nadine R; Moshfegh, Alanna J

    2018-01-01

    Distributing daily protein intake evenly across meals (∼25-30g/meal) has been suggested to improve muscle mass. The aim of this research is to examine the association between grip strength, total protein intake and its distribution across day's meals in older adults. Nationally representative dietary intake data of adults aged 51 years and older (n = 4,123) who participated in What We Eat in America, NHANES 2011-2014 were analyzed. Protein intake per day and per eating occasion (breakfast, lunch, dinner, and snack) were determined. Combined grip strength was calculated and expressed in kilograms. Grip strength of individuals consuming ≥25g protein at 1 eating occasion was compared with those consuming same level of protein at 2 and 3 or more eating occasions. Grip strength of individuals in quartile 1 of daily protein intake was compared to those in the other quartiles. All associations were examined without and with adjustment for age, race/ethnicity, physical activity, health status, and smoking status. The comparison involving eating occasions and protein intake quartiles were further adjusted for daily protein intake and energy intake, respectively. Only 33% of men and 19% of women had protein intake of ≥25g at 2 or more eating occasions. These individuals also had higher grip strength and daily protein intake. Grip strength was positively associated with consumption of ≥25g protein at 2 eating occasions as compared to consumption of same level of protein at 1 eating occasion (p<0.05) in unadjusted model, but not when adjusted. Grip strength was positively associated with daily protein intake among women in quartiles 3 and 4 (p<0.05) of protein intake in both unadjusted and adjusted models compared to lowest protein intake. Among men, grip strength was associated with daily protein intake in quartiles 3 and 4 (p<0.05) in the unadjusted model, but not when adjusted. In a nationally representative sample of older adults, consuming ≥25g protein at 2 or more eating occasions was not associated with grip strength. However, higher daily protein intake was positively associated with grip strength in women.

  18. Priming for Improved Hand Strength in Persons with Chronic Tetraplegia: A Comparison of Priming-Augmented Functional Task Practice, Priming Alone, and Conventional Exercise Training

    PubMed Central

    Gomes-Osman, Joyce; Tibbett, Jacqueline A.; Poe, Brandon P.; Field-Fote, Edelle C.

    2017-01-01

    Many everyday tasks cannot be accomplished without adequate grip strength, and corticomotor drive to the spinal motoneurons is a key determinant of grip strength. In persons with tetraplegia, damage to spinal pathways limits transmission of signals from motor cortex to spinal motoneurons. Corticomotor priming, which increases descending drive, should increase corticospinal transmission through the remaining spinal pathways resulting in increased grip strength. Since the motor and somatosensory cortices share reciprocal connections, corticomotor priming may also have potential to influence somatosensory function. The purpose of this study was to assess changes in grip (precision, power) force and tactile sensation associated with two different corticomotor priming approaches and a conventional training approach and to determine whether baseline values can predict responsiveness to training. Participants with chronic (≥1 year) tetraplegia (n = 49) were randomized to one of two corticomotor priming approaches: functional task practice plus peripheral nerve somatosensory stimulation (FTP + PNSS) or PNSS alone, or to conventional exercise training (CET). To assess whether baseline corticospinal excitability (CSE) is predictive of responsiveness to training, in a subset of participants, we assessed pre-intervention CSE of the thenar muscles. Participants were trained 2 h daily, 5 days/week for 4 weeks. Thirty-seven participants completed the study. Following intervention, significant improvements in precision grip force were observed in both the stronger and weaker hand in the FTP + PNSS group (effect size: 0.51, p = 0.04 and 0.54, p = 0.03, respectively), and significant improvements in weak hand precision grip force were associated with both PNSS and CET (effect size: 0.54, p = 0.03 and 0.75, p = 0.02, respectively). No significant changes were observed in power grip force or somatosensory scores in any group. Across all groups, responsiveness to training as measured by change in weak hand power grip force was correlated with baseline force. Change in precision grip strength was correlated with measures of baseline CSE. These findings indicate that corticomotor priming with FTP + PNSS had the greatest influence on precision grip strength in both the stronger and weaker hand; however, both PNSS and CET were associated with improved precision grip strength in the weaker hand. Responsiveness to training may be associated with baseline CSE. PMID:28144229

  19. Association between dietary protein intake and grip strength among adults aged 51 years and over: What We Eat in America, National Health and Nutrition Examination Survey 2011-2014

    PubMed Central

    Goldman, Joseph D.; Sahyoun, Nadine R.; Moshfegh, Alanna J.

    2018-01-01

    Introduction Distributing daily protein intake evenly across meals (∼25–30g/meal) has been suggested to improve muscle mass. The aim of this research is to examine the association between grip strength, total protein intake and its distribution across day’s meals in older adults. Methods Nationally representative dietary intake data of adults aged 51 years and older (n = 4,123) who participated in What We Eat in America, NHANES 2011–2014 were analyzed. Protein intake per day and per eating occasion (breakfast, lunch, dinner, and snack) were determined. Combined grip strength was calculated and expressed in kilograms. Grip strength of individuals consuming ≥25g protein at 1 eating occasion was compared with those consuming same level of protein at 2 and 3 or more eating occasions. Grip strength of individuals in quartile 1 of daily protein intake was compared to those in the other quartiles. All associations were examined without and with adjustment for age, race/ethnicity, physical activity, health status, and smoking status. The comparison involving eating occasions and protein intake quartiles were further adjusted for daily protein intake and energy intake, respectively. Results Only 33% of men and 19% of women had protein intake of ≥25g at 2 or more eating occasions. These individuals also had higher grip strength and daily protein intake. Grip strength was positively associated with consumption of ≥25g protein at 2 eating occasions as compared to consumption of same level of protein at 1 eating occasion (p<0.05) in unadjusted model, but not when adjusted. Grip strength was positively associated with daily protein intake among women in quartiles 3 and 4 (p<0.05) of protein intake in both unadjusted and adjusted models compared to lowest protein intake. Among men, grip strength was associated with daily protein intake in quartiles 3 and 4 (p<0.05) in the unadjusted model, but not when adjusted. Conclusion In a nationally representative sample of older adults, consuming ≥25g protein at 2 or more eating occasions was not associated with grip strength. However, higher daily protein intake was positively associated with grip strength in women. PMID:29364939

  20. Hand grip strength and its correlation with vitamin D in Indian patients with hip fracture.

    PubMed

    Dhanwal, Dinesh K; Dharmshaktu, Pramila; Gautam, V K; Gupta, N; Saxena, Alpana

    2013-01-01

    This case-control study was performed to evaluate 25-hydroxyvitamin D [25(OH)D] deficiency and its correlation with hand grip strength in 95 Indian hip fracture subjects and 95 controls. 25(OH)D deficiency was found in 88.4 % of hip fracture subjects that was significantly higher as compared to controls. Hand grip strength as measured by hand held dynamometer was significantly lower in patients, and there was a significant positive correlation between 25(OH)D and hand grip strength. The present study was conducted to assess correlation between 25(OH) D and hand grip strength in hip fracture subjects residing in North India. Ninety-five patients with hip fracture and similar number of controls were enrolled in the study. Fasting venous samples were analyzed for 25(OH)D, intact parathyroid hormone (PTH), alkaline phosphatase, calcium, and phosphate. Hand grip strength of study subjects was measured using Jamar dynamometer. Correlation between vitamin D levels and hand grip strength was analyzed in study population. The mean age of hip fracture subjects was 61.4 ± 12.6 years which was comparable in men and women. Out of 95 subjects, 57 were men and 38 were women. Mean 25(OH)D levels were significantly lower whereas intact PTH levels were significantly higher in patient group compared controls (10.29 ± 6.53 vs 13.6 ± 4.01 ng/ml; 62.6 ± 59.3 vs 37.7 ± 28.8 pg/ml, respectively). The number of subjects with 25(OH)D deficiency and secondary hyperparathyroidism was significantly higher in hip fracture group. The mean hand grip strength among hip fracture subjects was significantly lower compared to that of controls (16.57 ± 5.74 vs 26.74 ± 5.23 kg). There was a significant positive correlation between 25(OH)D and hand grip strength ( r = 0.482, p value <0.01) in hip fracture population. Majority of hip fracture patients in India have vitamin D deficiency, secondary hyperparathyroidism, and lower hand grip strength compared to controls. Further, there is significant positive correlation between 25(OH)D and hand grip strength.

  1. Isotropic and anisotropic strain-induced self-assembled oxide nanostructures

    NASA Astrophysics Data System (ADS)

    Gibert, Marta; Abellan, Patricia; Benedetti, Alessandro; Sandiumenge, Felip; Puig, Teresa; Obradors, Xavier

    2009-03-01

    The apparition of new functionalities based on size- and shape-dependent properties requires strategies for the formation of well-defined structures at nanometric scale. We present a bottom-up low-cost chemically-derived methodology based on the control of strain and surface energies anisotropies in CeO2/LAO system to tune the lateral aspect ratio, orientation and kinetics of interfacial oxide nanostructures. Self-organized uniform square-based nanopyramids form under isotropic strain [1]. In contrast, highly elongated nanostructures (long/short axis ˜20) grow induced by biaxial anisotropic strain and anisotropic surface energies. Island's distinct crystallographic orientation is the clue of their differentiated shape, and also influences their distinct evolution. The kinetically-limited coarsening of isotropic nanodots contrasts with the ultrafast kinetics of anisotropic islands. Experimental analyses are based on AFM, TEM, XRD and RHEED, and simulations based on a thermodynamic model enables us to confirm the equilibrium shape of each sort of island's shape in relation to its misfit strain and surface characteristics. [1] Gibert, M. et al., Adv.Materials 19 (22), 3937 (2007).

  2. The effect of force feedback delay on stiffness perception and grip force modulation during tool-mediated interaction with elastic force fields

    PubMed Central

    Karniel, Amir; Nisky, Ilana

    2015-01-01

    During interaction with objects, we form an internal representation of their mechanical properties. This representation is used for perception and for guiding actions, such as in precision grip, where grip force is modulated with the predicted load forces. In this study, we explored the relationship between grip force adjustment and perception of stiffness during interaction with linear elastic force fields. In a forced-choice paradigm, participants probed pairs of virtual force fields while grasping a force sensor that was attached to a haptic device. For each pair, they were asked which field had higher level of stiffness. In half of the pairs, the force feedback of one of the fields was delayed. Participants underestimated the stiffness of the delayed field relatively to the nondelayed, but their grip force characteristics were similar in both conditions. We analyzed the magnitude of the grip force and the lag between the grip force and the load force in the exploratory probing movements within each trial. Right before answering which force field had higher level of stiffness, both magnitude and lag were similar between delayed and nondelayed force fields. These results suggest that an accurate internal representation of environment stiffness and time delay was used for adjusting the grip force. However, this representation did not help in eliminating the bias in stiffness perception. We argue that during performance of a perceptual task that is based on proprioceptive feedback, separate neural mechanisms are responsible for perception and action-related computations in the brain. PMID:25717155

  3. Relationship between lung function and grip strength in older hospitalized patients: a pilot study

    PubMed Central

    Holmes, Sarah J; Allen, Stephen C; Roberts, Helen C

    2017-01-01

    Objective Older people with reduced respiratory muscle strength may be misclassified as having COPD on the basis of spirometric results. We aimed to evaluate the relationship between lung function and grip strength in older hospitalized patients without known airways disease. Methods Patients in acute medical wards were recruited who were aged ≥70 years; no history, symptoms, or signs of respiratory disease; Mini Mental State Examination ≥24; willing and able to consent to participate; and able to perform hand grip and forced spirometry. Data including lung function (forced expiratory volume in 1 second [FEV1], forced vital capacity [FVC], FEV1/FVC, peak expiratory flow rate [PEFR], and slow vital capacity [SVC]), grip strength, age, weight, and height were recorded. Data were analyzed using descriptive statistics and linear regression unadjusted and adjusted (for age, height, and weight). Results A total of 50 patients (20 men) were recruited. Stronger grip strength in men was significantly associated with greater FEV1, but this was attenuated by adjustment for age, height, and weight. Significant positive associations were found in women between grip strength and both PEFR and SVC, both of which remained robust to adjustment. Conclusion The association between grip strength and PEFR and SVC may reflect stronger patients generating higher intrathoracic pressure at the start of spirometry and pushing harder against thoracic cage recoil at end-expiration. Conversely, patients with weaker grip strength had lower PEFR and SVC. These patients may be misclassified as having COPD on the basis of spirometric results. PMID:28458532

  4. The development of tool use: Planning for end-state comfort

    PubMed Central

    Comalli, David M.; Keen, Rachel; Abraham, Evelyn S.; Foo, Victoria J.; Lee, Mei-Hua; Adolph, Karen E.

    2016-01-01

    Some grips on the handle of a tool can be planned based on information directly available in the scene. Other grips, however, must be planned based on the final position of the hand. “End-state comfort” grips require an awkward or uncomfortable initial grip so as to later implement the action comfortably and efficiently. From a cognitive perspective, planning for end-state comfort requires a consistent representation of the entire action sequence, including the latter part, which is not based on information directly available in the scene. Many investigators have found that young children fail to demonstrate planning for end-state comfort and that adult-like performance does not appear until about 12 years of age. In two experiments, we used a hammering task that engaged children in a goal-directed action with multiple steps. We assessed end-state-comfort planning in novel ways by measuring children’s hand choice, grip choice, and tool implementation over multiple trials. The hammering task also uniquely allowed us to assess the efficiency of implementation. We replicated the previous developmental trend in 4-, 8-, and 12-year-old children with our novel task. Most important, our data revealed that 4-year-olds are in a transitional stage with several competing strategies exhibited during a single session. Preschoolers changed their grip within trials and across trials, indicating awareness of errors and a willingness to sacrifice speed for more efficient implementation. The end-state-comfort grip initially competes as one grip type among many, but gradually displaces all others. Children’s sensitivity to and drive for efficiency may motivate this change. PMID:27786531

  5. Normative Measurements of Grip and Pinch Strengths of 21st Century Korean Population

    PubMed Central

    Shim, Jin Hee; Kim, Jin Soo; Lee, Dong Chul; Ki, Sae Hwi; Yang, Jae Won; Jeon, Man Kyung; Lee, Sang Myung

    2013-01-01

    Background Measuring grip and pinch strength is an important part of hand injury evaluation. Currently, there are no standardized values of normal grip and pinch strength among the Korean population, and lack of such data prevents objective evaluation of post-surgical recovery in strength. This study was designed to establish the normal values of grip and pinch strength among the healthy Korean population and to identify any dependent variables affecting grip and pinch strength. Methods A cross-sectional study was carried out. The inclusion criterion was being a healthy Korean person without a previous history of hand trauma. The grip strength was measured using a Jamar dynamometer. Pulp and key pinch strength were measured with a hydraulic pinch gauge. Intra-individual and inter-individual variations in these variables were analyzed in a standardized statistical manner. Results There were a total of 336 healthy participants between 13 and 77 years of age. As would be expected in any given population, the mean grip and pinch strength was greater in the right hand than the left. Male participants (137) showed mean strengths greater than female participants (199) when adjusted for age. Among the male participants, anthropometric variables correlated positively with grip strength, but no such correlations were identifiable in female participants in a statistically significant way. Conclusions Objective measurements of hand strength are an important component of hand injury evaluation, and population-specific normative data are essential for clinical and research purposes. This study reports updated normative hand strengths of the South Korean population in the 21st century. PMID:23362480

  6. Assessment of the presence/absence of the palmaris longus muscle in different sports, and elite and non-elite sport populations.

    PubMed

    Fowlie, Craig; Fuller, Colin; Pratten, Margaret K

    2012-06-01

    To investigate whether higher presence of the palmaris longus muscle is associated with sports that require hand grip. Cross-sectional study. Six hundred and forty-two medical students, members of sports clubs and national athletes. Participants were invited to complete a questionnaire that assessed their main sport, elite or non-elite level of participation, and level of activity. The presence of the palmaris longus was assessed visually using a standardised test. Presence of the palmaris longus, type of hand grip required for the sport and the level of participation. The presence of the palmaris longus was higher in elite athletes (21/22, 96%) than non-elite athletes (66/84, 79%; P=0.066) for sports that require a dominant-handed or two-handed cylindrical grip (18/22, 82% and 19/35, 54%, respectively; P=0.034). For both elite and non-elite athletes, the presence of the palmaris longus was higher in those participating in sustained grip sports (325/387, 84%) compared with sports that do not require a sustained grip (150/197, 76%; P=0.012). The palmaris longus may provide an advantage in certain types of sport that require hand grip, and for elite athletes participating in sports that require a dominant-handed or two-handed cylindrical hand grip. Orthopaedic specialists considering the use of the palmaris longus for a grafting procedure on an athlete should consider the level of participation and the type of hand grip required in the athlete's sport. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  7. The effect of force feedback delay on stiffness perception and grip force modulation during tool-mediated interaction with elastic force fields.

    PubMed

    Leib, Raz; Karniel, Amir; Nisky, Ilana

    2015-05-01

    During interaction with objects, we form an internal representation of their mechanical properties. This representation is used for perception and for guiding actions, such as in precision grip, where grip force is modulated with the predicted load forces. In this study, we explored the relationship between grip force adjustment and perception of stiffness during interaction with linear elastic force fields. In a forced-choice paradigm, participants probed pairs of virtual force fields while grasping a force sensor that was attached to a haptic device. For each pair, they were asked which field had higher level of stiffness. In half of the pairs, the force feedback of one of the fields was delayed. Participants underestimated the stiffness of the delayed field relatively to the nondelayed, but their grip force characteristics were similar in both conditions. We analyzed the magnitude of the grip force and the lag between the grip force and the load force in the exploratory probing movements within each trial. Right before answering which force field had higher level of stiffness, both magnitude and lag were similar between delayed and nondelayed force fields. These results suggest that an accurate internal representation of environment stiffness and time delay was used for adjusting the grip force. However, this representation did not help in eliminating the bias in stiffness perception. We argue that during performance of a perceptual task that is based on proprioceptive feedback, separate neural mechanisms are responsible for perception and action-related computations in the brain. Copyright © 2015 the American Physiological Society.

  8. Diet and its relationship with grip strength in community-dwelling older men and women: the Hertfordshire Cohort Study

    PubMed Central

    Robinson, Sian M; Jameson, Karen A; Batelaan, Sue F; Martin, Helen J; Syddall, Holly E; Dennison, Elaine M; Cooper, Cyrus; Sayer, Avan Aihie

    2007-01-01

    OBJECTIVES To examine relationships between diet and grip strength in older men and women, and to determine whether these relationships are modified by prenatal growth. DESIGN Cross-sectional and retrospective cohort study SETTING Hertfordshire, UK PARTICIPANTS Two thousand, nine hundred and eighty three men and women aged 59 to 73 years who were born and still live in Hertfordshire, UK MEASUREMENTS Weight at birth recorded in Health Visitor ledgers. Current food and nutrient intake assessed using an administered food frequency questionnaire, grip strength was measured with a hand-held dynamometer. RESULTS Grip strength was positively associated with height and weight at birth, and inversely related to age (all P<0.001). Of the dietary factors considered in relation to grip strength, the most important was fatty fish consumption. An increase in grip strength of 0.43kg (95% CI 0.13 to 0.74) in men (P=0.005), and 0.48kg (95% CI 0.24 to 0.72) in women (P<0.001), was observed for each additional portion of fatty fish consumed per week. These relationships were independent of adult height, age and birth weight, each of which had additive effects on grip strength. There was no evidence of interactive effects of weight at birth and adult diet on grip strength. CONCLUSION These data suggest that fatty fish consumption can have an important influence on muscle function in older men and women. This raises the possibility that the anti-inflammatory actions of n-3 fatty acids may play a role in the prevention of sarcopenia. PMID:18005355

  9. Inertial torque during reaching directly impacts grip-force adaptation to weightless objects.

    PubMed

    Giard, T; Crevecoeur, F; McIntyre, J; Thonnard, J-L; Lefèvre, P

    2015-11-01

    A hallmark of movement control expressed by healthy humans is the ability to gradually improve motor performance through learning. In the context of object manipulation, previous work has shown that the presence of a torque load has a direct impact on grip-force control, characterized by a significantly slower grip-force adjustment across lifting movements. The origin of this slower adaptation rate remains unclear. On the one hand, information about tangential constraints during stationary holding may be difficult to extract in the presence of a torque. On the other hand, inertial torque experienced during movement may also potentially disrupt the grip-force adjustments, as the dynamical constraints clearly differ from the situation when no torque load is present. To address the influence of inertial torque loads, we instructed healthy adults to perform visually guided reaching movements in weightlessness while holding an unbalanced object relative to the grip axis. Weightlessness offered the possibility to remove gravitational constraints and isolate the effect of movement-related feedback on grip force adjustments. Grip-force adaptation rates were compared with a control group who manipulated a balanced object without any torque load and also in weightlessness. Our results clearly show that grip-force adaptation in the presence of a torque load is significantly slower, which suggests that the presence of torque loads experienced during movement may alter our internal estimates of how much force is required to hold an unbalanced object stable. This observation may explain why grasping objects around the expected location of the center of mass is such an important component of planning and control of manipulation tasks.

  10. The nature and distribution of affiliative behaviour during exposure to mild threat

    PubMed Central

    Grèzes, Julie; Dahl, Christoph D.

    2017-01-01

    Individual reactions to danger in humans are often characterized as antisocial and self-preservative. Yet, more than 50 years of research have shown that humans often seek social partners and behave prosocially when confronted by danger. This research has relied on post hoc verbal reports, which fall short of capturing the more spontaneous reactions to danger and determine their social nature. Real-world responses to danger are difficult to observe, due to their evanescent nature. Here, we took advantage of a series of photographs freely accessible online and provided by a haunted house attraction, which enabled us to examine the more immediate reactions to mild threat. Regarding the nature and structure of affiliative behaviour and their motivational correlates, we were able to analyse the distribution of gripping, a behaviour that could either be linked to self- or other-oriented protection. We found that gripping, an affiliative behaviour, was common, suggestive of the social nature of human immediate reactions to danger. We also found that, while gripping behaviour is quite stable across group sizes, mutual gripping dropped dramatically as group size increases. The fact that mutual gripping disappears when the number of available partners increases suggests that gripping behaviour most probably reflects a self-preservative motivation. We also found age class differences, with younger individuals showing more gripping but receiving little reciprocation. Also, the most exposed individuals received little mutual gripping. Altogether, these results suggest that primary reactions to threat in humans are driven by affiliative tendencies serving self-preservative motives. PMID:28878976

  11. Kinetic Energy Corrections for Slip-Stick Behavior in Brittle Adhesives

    NASA Technical Reports Server (NTRS)

    Macon, David J.; Anderson, Greg L.; McCool, Alex (Technical Monitor)

    2001-01-01

    Fracture mechanics is the study of the failure of a body that contains a flaw. In the energy balance approach to fracture mechanics, contributions from the external work and elastic strain energy are accounted for but rarely are corrections for the kinetic energy given. Under slip-stick conditions, part of the external work is expended as kinetic energy. The magnitude of this kinetic energy depends upon the shape of the crack. A specimen with a blunt crack will fail at a high load and the crack will catastrophically travel through the material until the kinetic energy is dissipated. Material with a sharp crack will fail at a lower load but will still be catastrophic in nature. A kinetic term is incorporated into the energy balance approach. This term accounts for the velocity of the crack after failure and how far the crack travels before arresting. This correction makes the shape of the initiation crack irrelevant. When applied to data generated by tapered double cantilever beam specimens under slip-stick conditions, the scatter in the measured critical strain energy release rate is significantly reduced.

  12. 77 FR 23638 - Airworthiness Directives; Bell Helicopter Textron, Incorporated Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-20

    ... cycles for each grip on a component history card or equivalent record. Additionally, that AD requires you... each grip on a component history card or equivalent record. On the single-engine model helicopters, one... grip on a component history card or equivalent record. For each month that the hours TIS cannot be...

  13. Adaptive Force Control in Grasping as a Function of Level of Developmental Disability

    ERIC Educational Resources Information Center

    Sprague, R. L.; Deutsch, K. M.; Newell, K. M.

    2009-01-01

    Background: The adaptation to the task demands of grasping (grip mode and object mass) was investigated as a function of level of developmental disability. Methods: Subjects grasped objects of different grip widths and masses that were instrumented to record grip forces. Results: Proportionally, fewer participants from the profound compared with…

  14. ELECTROMAGNETIC APPARATUS FOR MOVING A ROD

    DOEpatents

    Young, J.N.

    1957-08-20

    An electromagnetic device for moving an object in a linear path by increments is described. The device is specifically adapted for moving a neutron absorbing control rod into and out of the core of a reactor and consists essentially of an extension member made of magnetic material connected to one end of the control rod and mechanically flexible to grip the walls of a sleeve member when flexed, a magnetic sleeve member coaxial with and slidable between limit stops along the flexible extension, electromagnetic coils substantially centrally located with respect to the flexible extension to flex the extension member into gripping engagement with the sleeve member when ener gized, moving electromagnets at each end of the sleeve to attract the sleeve when energized, and a second gripping electromagnet positioned along the flexible extension at a distance from the previously mentioned electromagnets for gripping the extension member when energized. In use, the second gripping electromagnet is deenergized, the first gripping electromagnet is energized to fix the extension member in the sleeve, and one of the moving electromagnets is energized to attract the sleeve member toward it, thereby moving the control rod.

  15. Switching in Feedforward Control of Grip Force During Tool-Mediated Interaction With Elastic Force Fields

    PubMed Central

    White, Olivier; Karniel, Amir; Papaxanthis, Charalambos; Barbiero, Marie; Nisky, Ilana

    2018-01-01

    Switched systems are common in artificial control systems. Here, we suggest that the brain adopts a switched feedforward control of grip forces during manipulation of objects. We measured how participants modulated grip force when interacting with soft and rigid virtual objects when stiffness varied continuously between trials. We identified a sudden phase transition between two forms of feedforward control that differed in the timing of the synchronization between the anticipated load force and the applied grip force. The switch occurred several trials after a threshold stiffness level in the range 100–200 N/m. These results suggest that in the control of grip force, the brain acts as a switching control system. This opens new research questions as to the nature of the discrete state variables that drive the switching. PMID:29930504

  16. Grip strength is not associated with incident type 2 diabetes mellitus in healthy adults: The CoLaus study.

    PubMed

    Marques-Vidal, Pedro; Vollenweider, Peter; Waeber, Gérard; Jornayvaz, François R

    2017-10-01

    We examined the association of grip strength with incident type 2 diabetes mellitus (T2DM) in healthy subjects initially aged 50 to 75years after a follow-up of 5.5years and 10.7years. This was a prospective, population-based study derived from the CoLaus (Cohorte Lausannoise) study including 2318 participants (aged 60.2y; 1354 women) free from T2DM at baseline. Grip strength was assessed using a handheld dynamometer. The effect of grip strength on the incidence of T2DM was analyzed by logistic regression. After a follow-up of 5.5years, 190 (8.2%) T2DM cases were identified. In bivariate analysis, participants who developed T2DM had a higher absolute grip strength (35.3±10.6 versus 33.2±10.7kg, P=0.013). Analysis between grip strength expressed in 5kg increment and incident TD2M showed a negative association when adjusted for age and sex [ORs (95% CI): 0.88 (0.79, 0.98)], or for age, sex and body mass index (BMI) [ORs (95% CI): 0.87 (0.78, 097)]. After a follow-up of 10.7years, 131 supplemental (7.3%) T2DM cases were identified, but there was no association between grip strength and incident T2DM in bivariate and multivariable analysis, potentially due to a lack of statistical power. In non elderly healthy adults, the risk of incident T2DM is overall not associated with grip strength over a maximum follow-up of 10.7years. Future studies are warranted to better assess the association between grip strength and incident T2DM in bigger and even younger cohorts. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Association of the AMPA receptor-related postsynaptic density proteins GRIP and ABP with subsets of glutamate-sensitive neurons in the rat retina.

    PubMed

    Gábriel, Robert; de Souza, Sunita; Ziff, Edward B; Witkovsky, Paul

    2002-07-22

    We used specific antibodies against two postsynaptic density proteins, GRIP (glutamate receptor interacting protein) and ABP (AMPA receptor-binding protein), to study their distribution in the rat retina. In the central nervous system, it has been shown that both proteins bind strongly to the AMPA glutamate receptor (GluR) 2/3 subunits, but not other GluRs, through a set of three PDZ domains. Western blots detected a single GRIP protein that was virtually identical in retina and brain, whereas retinal ABP corresponded to only one of three ABP peptides found in brain. The retinal distributions of GluR2/3, GRIP, and ABP immunoreactivity (IR) were similar but not identical. GluR2/3 immunoreactivity (IR) was abundant in both plexiform layers and in large perikarya. ABP IR was concentrated in large perikarya but was sparse in the plexiform layers, whereas GRIP IR was relatively more abundant in the plexiform layers than in perikarya. Immunolabel for these three antibodies consisted of puncta < or = 0.2 microm in diameter. The cellular localization of GRIP and ABP IR was examined by double labeling subclasses of retinal neuron with characteristic marker proteins, e.g., calbindin. GRIP, ABP, and GluR2/3 IR were detected in horizontal cells, dopaminergic and glycinergic AII amacrine cells and large ganglion cells. Immunolabel was absent in rod bipolar and weak or absent in cholinergic amacrine cells. By using the tyramide method of signal amplification, a colocalization of GluR2/3 was found with either GRIP or ABP in horizontal cell terminals, and perikarya of amacrine and ganglion cells. Our results show that ABP and GRIP colocalize with GluR2/3 in particular subsets of retinal neuron, as was previously established for certain neurons in the brain. Copyright 2002 Wiley-Liss, Inc.

  18. Morphology and kinetics of crystals growth in amorphous films of Cr2O3, deposited by laser ablation

    NASA Astrophysics Data System (ADS)

    Bagmut, Aleksandr

    2018-06-01

    An electron microscopic investigation was performed on the structure and kinetics of the crystallization of amorphous Cr2O3 films, deposited by pulsed laser sputtering of chromium target in an oxygen atmosphere. The crystallization was initiated by the action of an electron beam on an amorphous film in the column of a transmission electron microscope. The kinetic curves were plotted on the basis of a frame-by-frame analysis of the video recorded during the crystallization of the film. It was found that the amorphous phase - crystal phase transition in Cr2O3 films occurs as a layer polymorphic crystallization and is characterized by the values of the dimensionless relative length unit δ0 ≈ 2000-3100. The action of the electron beam initiates the formation of crystals of two basic morphological forms: disk-shaped and sickle-shaped. Growth of a disk-shaped crystals is characterized by a constant rate v and the quadratic dependence of the fraction of the crystalline phase x on the time t. Sickle-shaped crystal at an initial stage, as it grows, becomes as ring-shaped and disk-shaped crystal. The growth of a sickle-shaped crystal is characterized by normal and tangential velocity components, which depend on the time as ∼√t and as ∼1/√t respectively The end point of the arc at the interface between the amorphous and crystalline phases as the crystal grows describes a curve, which is similar to the Fermat helix. For sickle-shaped, as well as for disk-shaped crystals, the degree of crystallinity x ∼ t2.

  19. Kinetics of distribution of infections in networks

    NASA Astrophysics Data System (ADS)

    Avramov, I.

    2007-06-01

    SummaryWe develop a model for disease spreading in networks in a manner similar to the kinetics of crystallization of undercooled melts. The same kind of equations can be used in ecology and in sociology studies. For instance, they control the spread of gossip among the population. The time t dependence of the overall fraction α( t) of an infected network mass (individuals) affected by the disease is represented by an S-shaped curve. The derivative, i.e. the time dependence of intensity W( t) with which the epidemic evolves, is a bell-shaped curve. In essence, an analytical solution is offered describing the kinetics of spread of information along a ( d-dimensional) network.

  20. The Design of the Automatic Control System of the Gripping-Belt Speed in Long-Rootstalk Traditional Chinese Herbal Harvester

    NASA Astrophysics Data System (ADS)

    Huang, Jinxia; Wang, Junfa; Yu, Yonghong

    This article aims to design a kind of gripping-belt speed automatic tracking system of traditional Chinese herbal harvester by AT89C52 single-chip micro computer as a core combined with fuzzy PID control algorithm. The system can adjust the gripping-belt speed in accordance with the variation of the machine's operation, so there is a perfect matching between the machine operation speed and the gripping-belt speed. The harvesting performance of the machine can be improved greatly. System design includes hardware and software.

  1. GRIPS Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-07-31

    The GRIPS (Geothermal Resources Impact Projection Study) Commission was established by a Joint Powers Agreement between the California Counties of Lake, Mendocino, Napa, and Sonoma. The objectives of GRIPS are primarily to develop and use a cooperative environmental data collection and use system including natural, social, and economic considerations to facilitate their independent decisions and those of State and Federal agencies related to the environmental effects of geothermal development. This GRIPS Plan was prepared from a wide range of studies, workshops, and staff analyses. The plan is presented in four parts: summary and introduction; environmental data status report; planned programs;more » and budget. (MHR)« less

  2. Can grip strength be used as a surrogate marker to monitor recovery from shoulder fatigue?

    PubMed

    Hawkes, David; Grant, Michael; McMahon, Jessica; Horsley, Ian; Khaiyat, Omid

    2018-06-06

    Muscular fatigue impacts on normal shoulder function, which is particularly pertinent to throwing athletes. This study aimed to investigate the relationship between grip strength and shoulder muscle fatigue to evaluate the role of grip strength as a surrogate measure for upper limb performance. Twenty healthy participants were recruited. EMG was recorded from 15 shoulder muscles during different fatiguing contractions: an initial baseline recording (Fat-Baseline); after a shoulder exhausting exercise regime (Fat-Exhaustion); and after a 10 min rest period (Fat-Recovery). Grip strength was similarly measured in the same conditions. Grip strength differed significantly across the testing scenarios (p = 0.012-<0.001). Greater fatigue was seen in anterior deltoid, middle deltoid, posterior deltoid and supraspinatus in the Fat-Exhaustion contraction as compared to the Fat-Baseline contraction (p = <0.001-0.043). Greater fatigue was seen during the Fat-Recovery contraction for the trapezius, serratus anterior and biceps brachii as compared to the Fat-Exhaustion contraction (p = 0.008-0.038). Grip strength decreased following an exhausting exercise protocol but recovered to baseline following a rest period. Conversely, EMG indices of fatigue did not recover. Additional fatigue was seen reflecting a reorganisation of movement strategy. Therefore, susceptibility to injury still exists if grip strength alone is used as a barometer of upper limb performance. Copyright © 2018. Published by Elsevier Ltd.

  3. Ergonomic evaluation of a mechanical anastomotic stapler used by Japanese surgeons.

    PubMed

    Kono, Emiko; Tada, Mitsunori; Kouchi, Makiko; Endo, Yui; Tomizawa, Yasuko; Matsuo, Tomoko; Nomura, Sachiyo

    2014-06-01

    The satisfaction rating of currently available mechanical staplers for Japanese surgeons with small hands is low. To identify the issue, we examined the relationship of hand dimensions and grip force with the operation force of a mechanical circular stapler. Hand dimensions and grip force were measured in 113 Japanese surgeons (52 men and 61 women). We then evaluated the relationship between grip width and the operation force required to push the lever of the stapler, at three points on the lever, using a digital force gauge. The optimal grip width of the dominant hand was 62.5 ± 8.5 mm for men and 55.5 ± 5.9 mm for women (p < 0.001). The maximum grip force of the dominant hand was 44.2 ± 6.1 kg for men and 29.7 ± 4.5 kg for women (p < 0.001) and the maximum operation force required to push the lever 7.0, 45.0, and 73.0 mm from the end of the lever was 21.8, 28.6, and 42.4 kg, respectively. To our knowledge, this is the first ergonomic study of a surgical stapler to be conducted in Asia. Firing the stapler by gripping the proximal side of the lever is physically impossible for most Japanese women surgeons since the required operation force exceeds the maximum grip force, which probably accounts for the stress perceived by these women.

  4. Output control of da Vinci surgical system's surgical graspers.

    PubMed

    Johnson, Paul J; Schmidt, David E; Duvvuri, Umamaheswar

    2014-01-01

    The number of robot-assisted surgeries performed with the da Vinci surgical system has increased significantly over the past decade. The articulating movements of the robotic surgical grasper are controlled by grip controls at the master console. The user interface has been implicated as one contributing factor in surgical grasping errors. The goal of our study was to characterize and evaluate the user interface of the da Vinci surgical system in controlling surgical graspers. An angular manipulator with force sensors was used to increment the grip control angle as grasper output angles were measured. Input force at the grip control was simultaneously measured throughout the range of motion. Pressure film was used to assess the maximum grasping force achievable with the endoscopic grasping tool. The da Vinci robot's grip control angular input has a nonproportional relationship with the grasper instrument output. The grip control mechanism presents an intrinsic resistant force to the surgeon's fingertips and provides no haptic feedback. The da Vinci Maryland graspers are capable of applying up to 5.1 MPa of local pressure. The angular and force input at the grip control of the da Vinci robot's surgical graspers is nonproportional to the grasper instrument's output. Understanding the true relationship of the grip control input to grasper instrument output may help surgeons understand how to better control the surgical graspers and promote fewer grasping errors. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. GRIP Experiment

    NASA Image and Video Library

    2018-06-11

    iss056e009784 (June 11, 2018) --- Expedition 56 Flight Engineer Alexander Gerst of the European Space Agency (ESA) is seated in the Columbus laboratory module participating in the Grip study. Grip is an ESA-sponsored experiment that is researching how the nervous system adapts to microgravity. Observations may improve the design of safer space habitats and help patients on Earth with neurological diseases.

  6. GRIP Experiment

    NASA Image and Video Library

    2018-06-11

    iss056e009783 (June 11, 2018) --- Expedition 56 Flight Engineer Alexander Gerst of the European Space Agency (ESA) is seated in the Columbus laboratory module participating in the Grip study. Grip is an ESA-sponsored experiment that is researching how the nervous system adapts to microgravity. Observations may improve the design of safer space habitats and help patients on Earth with neurological diseases.

  7. Grip Experiment 2010

    NASA Image and Video Library

    2010-08-16

    A researcher with the Genesis and Rapid Intensification Processes (GRIP) experiment works aboard the NASA DC-8 during a flight over the Gulf of Mexico, Tuesday, Aug. 17, 2010. GRIP is a NASA Earth science field experiment in 2010 that is being conducted to better understand how tropical storms form and develop into major hurricanes. Photo Credit: (NASA/Paul E. Alers)

  8. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BICYCLES Pt. 1512, Fig. 5 Figure 5 to Part 1512—Typical Handbrake Actuator Showing Grip Dimension...

  9. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BICYCLES Pt. 1512, Fig. 5 Figure 5 to Part 1512—Typical Handbrake Actuator Showing Grip Dimension...

  10. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BICYCLES Pt. 1512, Fig. 5 Figure 5 to Part 1512—Typical Handbrake Actuator Showing Grip Dimension...

  11. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BICYCLES Pt. 1512, Fig. 5 Figure 5 to Part 1512—Typical Handbrake Actuator Showing Grip Dimension...

  12. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BICYCLES Pt. 1512, Fig. 5 Figure 5 to Part 1512—Typical Handbrake Actuator Showing Grip Dimension...

  13. Shape transitions in strained Cu islands on Ni(100): kinetics versus energetics

    NASA Astrophysics Data System (ADS)

    Shim, Yunsic; Amar, Jacques

    2012-02-01

    We examine the shape transition from compact to ramified islands observed in submonolayer Cu/Ni(100) growth. Recently, it has been argued that this transition is not due to a growth instability but can be understood in terms of energetic arguments. In order to determine the responsible mechanisms we have carried out energetics calculations as well as temperature-accelerated dynamics (TAD) and kinetic Monte Carlo (KMC) simulations. Our results indicate that the shape transition cannot be explained by equilibrium arguments, but is instead due to kinetic effects which are mediated by strain. In particular, by calculating the relevant line-tension and strain energies, we find that the equilibrium critical island-width is at least four orders of magnitude larger than the experimentally observed arm-width. In contrast, our TAD simulations indicate that unexpected concerted motions occurring at step edges are responsible. The energy barriers for these concerted motions decrease with increasing island size and appear to saturate for islands larger than 300 - 400 atoms. By including these strain-induced kinetic processes in our KMC simulations of island-growth, we have been able to explain both the temperature- and coverage-dependence of the island morphology.

  14. Grip Strength Is Associated With Cognitive Performance in Schizophrenia and the General Population: A UK Biobank Study of 476559 Participants.

    PubMed

    Firth, Joseph; Stubbs, Brendon; Vancampfort, Davy; Firth, Josh A; Large, Matthew; Rosenbaum, Simon; Hallgren, Mats; Ward, Philip B; Sarris, Jerome; Yung, Alison R

    2018-06-06

    Handgrip strength may provide an easily-administered marker of cognitive functional status. However, further population-scale research examining relationships between grip strength and cognitive performance across multiple domains is needed. Additionally, relationships between grip strength and cognitive functioning in people with schizophrenia, who frequently experience cognitive deficits, has yet to be explored. Baseline data from the UK Biobank (2007-2010) was analyzed; including 475397 individuals from the general population, and 1162 individuals with schizophrenia. Linear mixed models and generalized linear mixed models were used to assess the relationship between grip strength and 5 cognitive domains (visual memory, reaction time, reasoning, prospective memory, and number memory), controlling for age, gender, bodyweight, education, and geographical region. In the general population, maximal grip strength was positively and significantly related to visual memory (coefficient [coeff] = -0.1601, standard error [SE] = 0.003), reaction time (coeff = -0.0346, SE = 0.0004), reasoning (coeff = 0.2304, SE = 0.0079), number memory (coeff = 0.1616, SE = 0.0092), and prospective memory (coeff = 0.3486, SE = 0.0092: all P < .001). In the schizophrenia sample, grip strength was strongly related to visual memory (coeff = -0.155, SE = 0.042, P < .001) and reaction time (coeff = -0.049, SE = 0.009, P < .001), while prospective memory approached statistical significance (coeff = 0.233, SE = 0.132, P = .078), and no statistically significant association was found with number memory and reasoning (P > .1). Grip strength is significantly associated with cognitive functioning in the general population and individuals with schizophrenia, particularly for working memory and processing speed. Future research should establish directionality, examine if grip strength also predicts functional and physical health outcomes in schizophrenia, and determine whether interventions which improve muscular strength impact on cognitive and real-world functioning.

  15. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating

    PubMed Central

    2017-01-01

    Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro–Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves. PMID:29207573

  16. Motor control goes beyond physics: differential effects of gravity and inertia on finger forces during manipulation of hand-held objects.

    PubMed

    Zatsiorsky, Vladimir M; Gao, Fan; Latash, Mark L

    2005-04-01

    According to basic physics, the local effects induced by gravity and acceleration are identical and cannot be separated by any physical experiment. In contrast-as this study shows-people adjust the grip forces associated with gravitational and inertial forces differently. In the experiment, subjects oscillated a vertically-oriented handle loaded with five different weights (from 3.8 N to 13.8 N) at three different frequencies in the vertical plane: 1 Hz, 1.5 Hz and 2.0 Hz. Three contributions to the grip force-static, dynamic, and stato-dynamic fractions-were quantified. The static fraction reflects grip force related to holding a load statically. The stato-dynamic fraction reflects a steady change in the grip force when the same load is moved cyclically. The dynamic fraction is due to acceleration-related adjustments of the grip force during oscillation cycles. The slope of the relation between the grip force and the load force was steeper for the static fraction than for the dynamic fraction. The stato-dynamic fraction increased with the frequency and load. The slope of the dynamic grip force-load force relation decreased with frequency, and as a rule, increased with the load. Hence, when adjusting grip force to task requirements, the central controller takes into account not only the expected magnitude of the load force but also such factors as whether the force is gravitational or inertial and the contributions of the object mass and acceleration to the inertial force. As an auxiliary finding, a complex finger coordination pattern aimed at preserving the rotational equilibrium of the object during shaking movements was reported.

  17. Longitudinal assessment of grip strength using bulb dynamometer in Duchenne Muscular Dystrophy

    PubMed Central

    Pizzato, Tatiana M.; Baptista, Cyntia R. J. A.; Souza, Mariana A.; Benedicto, Michelle M. B.; Martinez, Edson Z.; Mattiello-Sverzut, Ana C.

    2014-01-01

    BACKGROUND: Grip strength is used to infer functional status in several pathological conditions, and the hand dynamometer has been used to estimate performance in other areas. However, this relationship is controversial in neuromuscular diseases and studies with the bulb dynamometer comparing healthy children and children with Duchenne Muscular Dystrophy (DMD) are limited. OBJECTIVE: The evolution of grip strength and the magnitude of weakness were examined in boys with DMD compared to healthy boys. The functional data of the DMD boys were correlated with grip strength. METHOD: Grip strength was recorded in 18 ambulant boys with DMD (Duchenne Group, DG) aged 4 to 13 years (mean 7.4±2.1) and 150 healthy volunteers (Control Group, CG) age-matched using a bulb dynamometer (North Coast- NC70154). The follow-up of the DG was 6 to 33 months (3-12 sessions), and functional performance was verified using the Vignos scale. RESULTS: There was no difference between grip strength obtained by the dominant and non-dominant side for both groups. Grip strength increased in the CG with chronological age while the DG remained stable or decreased. The comparison between groups showed significant difference in grip strength, with CG values higher than DG values (confidence interval of 95%). In summary, there was an increment in the differences between the groups with increasing age. Participants with 24 months or more of follow-up showed a progression of weakness as well as maintained Vignos scores. CONCLUSIONS: The amplitude of weakness increased with age in the DG. The bulb dynamometer detected the progression of muscular weakness. Functional performance remained virtually unchanged in spite of the increase in weakness. PMID:25003277

  18. Association between grip strength and diabetes prevalence in black, South-Asian, and white European ethnic groups: a cross-sectional analysis of 418 656 participants in the UK Biobank study.

    PubMed

    Ntuk, U E; Celis-Morales, C A; Mackay, D F; Sattar, N; Pell, J P; Gill, J M R

    2017-08-01

    To quantify the extent to which ethnic differences in muscular strength might account for the substantially higher prevalence of diabetes in black and South-Asian compared with white European adults. This cross-sectional study used baseline data from the UK Biobank study on 418 656 white European, black and South-Asian participants, aged 40-69 years, who had complete data on diabetes status and hand-grip strength. Associations between hand-grip strength and diabetes were assessed using logistic regression and were adjusted for potential confounding factors. Lower grip strength was associated with higher prevalence of diabetes, independent of confounding factors, across all ethnicities in both men and women. Diabetes prevalence was approximately three- to fourfold higher in South-Asian and two- to threefold higher in black participants compared with white European participants across all levels of grip strength, but grip strength in South-Asian men and women was ~ 5-6 kg lower than in the other ethnic groups. Thus, the attributable risk for diabetes associated with low grip strength was substantially higher in South-Asian participants (3.9 and 4.2 cases per 100 men and women, respectively) than in white participants (2.0 and 0.6 cases per 100 men and women, respectively). Attributable risk associated with low grip strength was also high in black men (4.3 cases) but not in black women (0.4 cases). Low strength is associated with a disproportionately large number of diabetes cases in South-Asian men and women and in black men. Trials are needed to determine whether interventions to improve strength in these groups could help reduce ethnic inequalities in diabetes prevalence. © 2017 Diabetes UK.

  19. Grip Strength as a Marker of Hypertension and Diabetes in Healthy Weight Adults

    PubMed Central

    Mainous, Arch G.; Tanner, Rebecca J.; Anton, Stephen D.; Jo, Ara

    2015-01-01

    Introduction Muscle strength may play a role in cardiometabolic disease. We examined the relationship between hand grip strength and diabetes and hypertension in a sample of healthy weight adults. Methods In 2015, we analyzed the National Health and Nutrition Examination Survey 2011–2012 for adults aged ≥20 years with healthy BMIs (between 18.5 and <25 kg/m2) and no history of cardiovascular disease (unweighted n=1,469; weighted n=61,672,082). Hand grip strength was assessed with a dynamometer. Diabetes was based on hemoglobin A1c level and reported diabetes diagnosis. Hypertension was based on measured blood pressure and reported hypertension diagnosis. Results Individuals with undiagnosed diabetes compared with individuals without diabetes had lower grip strength (51.9 vs 69.8, p=0.0001), as well as among individuals with diagnosed diabetes compared with individuals without diabetes (61.7 vs 69.8, p=0.008). Mean grip strength was lower among individuals with undiagnosed hypertension compared with individuals without hypertension (63.5 vs 71.5, p=0.008) as well as among individuals with diagnosed hypertension compared with those without hypertension (60.8 vs 71.5, p<0.0001). In adjusted analyses controlling for age, sex, race, smoking status, and first-degree relative with disease, mean grip strength was lower for undiagnosed diabetes (β= −10.02, p<0.0001) and diagnosed diabetes (β= −8.21, p=0.03) compared with individuals without diabetes. In adjusted analyses, grip strength was lower among individuals with undiagnosed hypertension (β= −6.6, p=0.004) and diagnosed hypertension (β= −4.27, p=0.04) compared with individuals without hypertension. Conclusions Among healthy weight adults, combined grip strength is lower in individuals with diagnosed and undiagnosed diabetes and hypertension. PMID:26232901

  20. Kinetics of Magnetoelastic Twin-Boundary Motion in Ferromagnetic Shape-Memory Alloys

    NASA Astrophysics Data System (ADS)

    Pramanick, A.; Wang, X.-L.; Stoica, A. D.; Yu, C.; Ren, Y.; Tang, S.; Gai, Z.

    2014-05-01

    We report the kinetics of twin-boundary motion in the ferromagnetic shape-memory alloy of Ni-Mn-Ga as measured by in situ high energy synchrotron diffraction. The temporal evolution of twin reorientation during the application of a magnetic field is described by thermally activated creep motion of twin boundaries over a distribution of energy barriers. The dynamical creep exponent μ was found to be ˜0.5, suggesting that the distribution of energy barriers is a result of short-range disorders.

  1. Development of an integrated digital hand grip dynamometer and norm of hand grip strength.

    PubMed

    Chang, Ho; Chen, Chih-Hao; Huang, Tung-Sun; Tai, Chun-Yen

    2015-01-01

    This study designs and fabricates a novel integrated digital hand grip dynamometer and analyzes collected grip strength data. The dynamometer directly stores collected data in a computer, unlike those on the market that cannot directly store information. A strain gauge load cell is used as a force sensor. The dynamometer is designed to maximize ergonomics. Excitation voltage of the load cell is 5 V, and a 9 V battery supplies power to its circuit. The signal receiver is National Instruments (NI) data acquisition (DAQ) card that transmits signals to the computer. The operation system is designed using LabView. This study assesses the correlation between variables of collected data. The correlation coefficients for height, weight and palm length were 0.793, 0.609 and 0.715, respectively, indicating that variables were moderately to strongly correlate with grip strength.

  2. Hand Strength, Handwriting, and Functional Skills in Children With Autism.

    PubMed

    Alaniz, Michele L; Galit, Eleanor; Necesito, Corina Isabel; Rosario, Emily R

    2015-01-01

    To establish hand strength development trends in children with autism and to investigate correlations between grip and pinch strength, components of handwriting, and functional activities in children with and without autism. Fifty-one children were divided into two groups: typically developing children and children on the autism spectrum. Each child completed testing for pinch and grip strength, handwriting legibility, pencil control, and independence in functional activities. The children with autism followed the same strength development trends as the typically developing children. Grip strength correlated with pencil control in both groups and with handwriting legibility in the typically developing children but not in the children with autism. Grip and pinch strength correlated with independence with functional activities in both groups. This study provides evidence that grip and pinch strength are important components in developing pencil control, handwriting legibility, and independence with functional fine motor tasks. Copyright © 2015 by the American Occupational Therapy Association, Inc.

  3. Quantitative assessment of motor fatigue: normative values and comparison with prior-polio patients.

    PubMed

    Meldrum, Dara; Cahalane, Eibhlis; Conroy, Ronan; Guthrie, Richard; Hardiman, Orla

    2007-06-01

    Motor fatigue is a common complaint of polio survivors and has a negative impact on activities of daily living. The aim of this study was to establish a normative database for hand grip strength and fatigue and to investigate differences between prior-polio subjects and normal controls. Static and dynamic hand grip fatigue and maximum voluntary isometric contraction (MVIC) of hand grip were measured in subjects with a prior history of polio (n = 44) and healthy controls (n = 494). A normative database of fatigue was developed using four indices of analysis. Compared with healthy controls, subjects with prior polio had significantly reduced hand grip strength but developed greater hand grip fatigue in only one fatigue index. Quantitative measurement of fatigue in the prior-polio population may be useful in order to detect change over time and to evaluate treatment strategies.

  4. A validated finite element model of a soft artificial muscle motor

    NASA Astrophysics Data System (ADS)

    Tse, Tony Chun H.; O'Brien, Benjamin; McKay, Thomas; Anderson, Iain A.

    2011-04-01

    The Biomimetics Laboratory has developed a soft artificial muscle motor based on Dielectric Elastomers. The motor, 'Flexidrive', is light-weight and has low system complexity. It works by gripping and turning a shaft with a soft gear, like we would with our fingers. The motor's performance depends on many factors, such as actuation waveform, electrode patterning, geometries and contact tribology between the shaft and gear. We have developed a finite element model (FEM) of the motor as a study and design tool. Contact interaction was integrated with previous material and electromechanical coupling models in ABAQUS. The model was experimentally validated through a shape and blocked force analysis.

  5. The influence of anthropological features on ball flight speed in handball.

    PubMed

    Srhoj, Vatromir; Rogulj, Nenad; Papić, Vladan; Foretić, Nikola; Cavala, Marijana

    2012-09-01

    The purpose of this study, done on the sample of 41 students of Faculty of Kinesiologyi in Split was to determinate the differences in anthropological characteristics between students who achieved above average and students who achieved under average ball flight speed after jump shoot in handball. Anthropological characteristics were defined by 16 variables, 6 of them were used for the estimation of morphological characteristics, 7 variables for evaluation of motor characteristics and one variable each for evaluation of kinetic, kinematics and technical parameters of shooting. The significant differences were determined in variables for evaluation of longitudinal dimensionality of dominant arm, explosive strength of pull-out agility, strength of the hand grip, hand flexion ability for the ball throw-out and finally, correct and sound technique of the throw-out movement.

  6. Prognostic value of grip strength: findings from the Prospective Urban Rural Epidemiology (PURE) study.

    PubMed

    Leong, Darryl P; Teo, Koon K; Rangarajan, Sumathy; Lopez-Jaramillo, Patricio; Avezum, Alvaro; Orlandini, Andres; Seron, Pamela; Ahmed, Suad H; Rosengren, Annika; Kelishadi, Roya; Rahman, Omar; Swaminathan, Sumathi; Iqbal, Romaina; Gupta, Rajeev; Lear, Scott A; Oguz, Aytekin; Yusoff, Khalid; Zatonska, Katarzyna; Chifamba, Jephat; Igumbor, Ehimario; Mohan, Viswanathan; Anjana, Ranjit Mohan; Gu, Hongqiu; Li, Wei; Yusuf, Salim

    2015-07-18

    Reduced muscular strength, as measured by grip strength, has been associated with an increased risk of all-cause and cardiovascular mortality. Grip strength is appealing as a simple, quick, and inexpensive means of stratifying an individual's risk of cardiovascular death. However, the prognostic value of grip strength with respect to the number and range of populations and confounders is unknown. The aim of this study was to assess the independent prognostic importance of grip strength measurement in socioculturally and economically diverse countries. The Prospective Urban-Rural Epidemiology (PURE) study is a large, longitudinal population study done in 17 countries of varying incomes and sociocultural settings. We enrolled an unbiased sample of households, which were eligible if at least one household member was aged 35-70 years and if household members intended to stay at that address for another 4 years. Participants were assessed for grip strength, measured using a Jamar dynamometer. During a median follow-up of 4.0 years (IQR 2.9-5.1), we assessed all-cause mortality, cardiovascular mortality, non-cardiovascular mortality, myocardial infarction, stroke, diabetes, cancer, pneumonia, hospital admission for pneumonia or chronic obstructive pulmonary disease (COPD), hospital admission for any respiratory disease (including COPD, asthma, tuberculosis, and pneumonia), injury due to fall, and fracture. Study outcomes were adjudicated using source documents by a local investigator, and a subset were adjudicated centrally. Between January, 2003, and December, 2009, a total of 142,861 participants were enrolled in the PURE study, of whom 139,691 with known vital status were included in the analysis. During a median follow-up of 4.0 years (IQR 2.9-5.1), 3379 (2%) of 139,691 participants died. After adjustment, the association between grip strength and each outcome, with the exceptions of cancer and hospital admission due to respiratory illness, was similar across country-income strata. Grip strength was inversely associated with all-cause mortality (hazard ratio per 5 kg reduction in grip strength 1.16, 95% CI 1.13-1.20; p<0.0001), cardiovascular mortality (1.17, 1.11-1.24; p<0.0001), non-cardiovascular mortality (1.17, 1.12-1.21; p<0.0001), myocardial infarction (1.07, 1.02-1.11; p=0.002), and stroke (1.09, 1.05-1.15; p<0.0001). Grip strength was a stronger predictor of all-cause and cardiovascular mortality than systolic blood pressure. We found no significant association between grip strength and incident diabetes, risk of hospital admission for pneumonia or COPD, injury from fall, or fracture. In high-income countries, the risk of cancer and grip strength were positively associated (0.916, 0.880-0.953; p<0.0001), but this association was not found in middle-income and low-income countries. This study suggests that measurement of grip strength is a simple, inexpensive risk-stratifying method for all-cause death, cardiovascular death, and cardiovascular disease. Further research is needed to identify determinants of muscular strength and to test whether improvement in strength reduces mortality and cardiovascular disease. Full funding sources listed at end of paper (see Acknowledgments). Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Note on performance of tapered grip tensile loading devices

    NASA Technical Reports Server (NTRS)

    Jones, M. H.; Brown, W. F., Jr.

    1975-01-01

    Alignment results are presented in terms of percent bending for a quick release, tapered grip, tensile loading device that has been proposed for testing sharply notched specimens of aluminum and magnesium alloys by a Task Group of the ASTM Committee E-24 on Fracture Testing of Metals. The results show that the bending introduced by the fixtures is strongly dependent on their relative rotational positions in respect to the loading rods which adapt them, to the tensile machine. For one set of tapered grips the highest bending was about 15%. Recommendations are made for improvement in the design of the tapered grips which should reduce the bending stresses substantially.

  8. The influence of golf shaft stiffness on grip and clubhead kinematics.

    PubMed

    MacKenzie, Sasho J; Boucher, Daniel E

    2017-01-01

    The purpose of this study was to investigate the influence of shaft stiffness on grip and clubhead kinematics. Two driver shafts with disparate levels of stiffness, but very similar inertial properties, were tested by 33 golfers representing a range of abilities. Shaft deflection data as well as grip and clubhead kinematics were collected from 14 swings, with each shaft, for each golfer using an optical motion capture system. The more flexible shaft (R-Flex) demonstrated a higher contribution to clubhead speed from shaft deflection dynamics (P < .001), but was also associated with significantly less grip angular velocity at impact (P = .001), resulting in no significant difference in clubhead speed (P = .14). However, at the individual level, half of the participants demonstrated a significant difference in clubhead speed between shafts. The more flexible shaft was also associated with significantly different magnitudes of head rotation relative to the grip. More specifically, both bend loft (P < .001) and bend lie (P < .001) were greater for the R-Flex shaft, while bend close (P = .017) was greater for the stiffer (X-Flex) shaft. However, changes in grip orientation resulted in no significant differences in face orientation, between the shafts, at impact.

  9. Attentional Focus and Grip Width Influences on Bench Press Resistance Training.

    PubMed

    Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, JuanCarlos; Andersen, Lars L

    2018-04-01

    This study evaluated the influence of different attentional foci for varied grip widths in the bench press. Eighteen resistance-trained men were familiarized with the procedure and performed a one-repetition maximum (1RM) test during Session 1. In Session 2, they used three different standardized grip widths (100%, 150%, and 200% of biacromial width distance) in random order at 50% of 1RM while also engaged in three different attention focus conditions (external focus on the bench press, internal focus on pectoralis major muscles, and internal focus on triceps brachii muscles). Surface electromyography (EMG) signals were recorded from the triceps brachii and pectoralis major, and peak EMG of the filtered signals were normalized to maximum EMG of each muscle. Both grip width and focus influenced the muscle activity level, but there were no significant interactions between these variables. Exploratory analyses suggested that an internal focus may slightly (4%-6%) increase pectoralis major activity at wider grip widths and triceps brachii activity at narrower grip widths, but this should be confirmed or rejected in a study with a larger sample size or through a meta-analysis of research to date.

  10. [Gait speed, grip strength and self-rated health among the elderly: data from the FIBRA Campinas network, São Paulo, Brazil].

    PubMed

    Bez, Joelita Pessoa de Oliveira; Neri, Anita Liberalesso

    2014-08-01

    The article seeks to investigate patterns of performance and relationships between grip strength, gait speed and self-rated health, and investigate the relationships between them, considering the variables of gender, age and family income. This was conducted in a probabilistic sample of community-dwelling elderly aged 65 and over, members of a population study on frailty. A total of 689 elderly people without cognitive deficit suggestive of dementia underwent tests of gait speed and grip strength. Comparisons between groups were based on low, medium and high speed and strength. Self-related health was assessed using a 5-point scale. The males and the younger elderly individuals scored significantly higher on grip strength and gait speed than the female and oldest did; the richest scored higher than the poorest on grip strength and gait speed; females and men aged over 80 had weaker grip strength and lower gait speed; slow gait speed and low income arose as risk factors for a worse health evaluation. Lower muscular strength affects the self-rated assessment of health because it results in a reduction in functional capacity, especially in the presence of poverty and a lack of compensatory factors.

  11. Comparison of pressure pain threshold, grip strength,dexterity and touch pressure of dominant and non-dominant hands within and between right-and left-handed subjects.

    PubMed

    Ozcan, Ayse; Tulum, Zeliha; Pinar, Lamia; Başkurt, Ferdi

    2004-12-01

    This study was done to evaluate differences in pressure pain threshold, grip strength, manual dexterity and touch pressure threshold in the dominant and non-dominant hands of right- and left-handed subjects, and to compare findings within and between these groups. Thirty-nine right-handed and twenty-one left-handed subjects participated in the study. Pressure pain threshold was assessed using a dolorimeter, grip strength was assessed with a hand-grip dynamometer, manual dexterity was evaluated using the VALPAR Component Work Sample-4 system, and touch pressure threshold was determined using Semmes Weinstein monofilaments. Results for the dominant and non-dominant hands were compared within and between the groups. In the right-handed subjects, the dominant hand was significantly faster with the VALPAR Component Work Sample-4, showed significantly greater grip strength, and had a significantly higher pressure pain threshold than the non-dominant hand. The corresponding results for the two hands were similar in the left-handed subjects. The study revealed asymmetrical manual performance in grip strength, manual dexterity and pressure pain threshold in right-handed subjects, but no such asymmetries in left-handed subjects.

  12. Identification of Dynapenia in Older Adults Through the Use of Grip Strength T-Scores

    PubMed Central

    Bohannon, Richard W; Magasi, Susan

    2014-01-01

    Objective To generate reference values and t-scores (1.0 to 2.5 standard deviations below average) for grip strength for healthy young adults and to examine the utility of t-scores from this group for the identification of dynapenia in older adults. Design Secondary analysis of cross-sectional grip strength data from the NIH Toolbox norming sample. Setting Population-based general community sample. Participants Community dwelling adults, between the ages 20 and 40 years (n=558); and 60 to 85 years (n=390) Main Outcomes Measures Grip strength measured with a Jamar plus dynamometer. Results Maximum grip strengths were consistent over the 20–40 year age span. For men they were 108.0 lbs (S.D. 22.6). For women, they were 65.8 lbs (S.D. 14.6) Comparison of older participant grip strengths to those of the younger reference group revealed (depending on age strata) that 46.2–87.1% of older men and 50.0–82.4% of older women could be designated as dynapenic on the basis of t-scores. Conclusion The use of reference value t-scores from younger adults is a promising method for determining dynapenia in older adults. PMID:24729356

  13. Identification of dynapenia in older adults through the use of grip strength t-scores.

    PubMed

    Bohannon, Richard W; Magasi, Susan

    2015-01-01

    The aim of this study was to generate reference values and t-scores (1.0-2.5 standard deviations below average) for grip strength for healthy young adults and to examine the utility of t-scores from this group for the identification of dynapenia in older adults. Our investigation was a population-based, general community secondary analysis of cross-sectional grip strength data utilizing the NIH Toolbox Assessment norming sample. Participants consisted of community-dwelling adults, with age ranges of 20-40 years (n = 558) and 60-85 years (n = 390). The main outcome measure was grip strength using a Jamar plus dynamometer. Maximum grip strengths were consistent over the 20-40-year age group [men 108.0 (SD 22.6) pounds, women 65.8 (SD 14.6) pounds]. Comparison of older group grip strengths to those of the younger reference group revealed (depending on age strata) that 46.2-87.1% of older men and 50.0-82.4% of older women could be designated as dynapenic on the basis of t-scores. The use of reference value t-scores from younger adults is a promising method for determining dynapenia in older adults. © 2014 Wiley Periodicals, Inc.

  14. Cutting moments and grip forces in meat cutting operations and the effect of knife sharpness.

    PubMed

    McGorry, Raymond W; Dowd, Peter C; Dempsey, Patrick G

    2003-07-01

    The force exposure associated with meat cutting operations and the effect of knife sharpness on performance and productivity have not been well documented. Specialized hardware was used to measure grip force and reactive moments with 15 professional meat cutters performing lamb shoulder boning, beef rib trimming and beef loin trim operations in a field study conducted in two meat packing plants. A system for measuring relative blade sharpness was developed for this study. Mean and peak cutting moments observed for the meat cutting operations, averaged across subjects were 4.7 and 17.2 Nm for the shoulder boning, 3.5 and 12.9 Nm for the rib trim, and 2.3 and 10.6 Nm for the loin trim, respectively. Expressed as percent of MVC, mean grip forces of 28.3% and peak grip forces of 72.6% were observed overall. Blade sharpness was found to effect grip forces, cutting moments and cutting time, with sharper blades requiring statistically significantly lower peak and mean cutting moments, and grip forces than dull knives. Efforts aimed at providing and maintaining sharp blades could have a significant impact on force exposure.

  15. The effect of ergonomic laparoscopic tool handle design on performance and efficiency.

    PubMed

    Tung, Kryztopher D; Shorti, Rami M; Downey, Earl C; Bloswick, Donald S; Merryweather, Andrew S

    2015-09-01

    Many factors can affect a surgeon's performance in the operating room; these may include surgeon comfort, ergonomics of tool handle design, and fatigue. A laparoscopic tool handle designed with ergonomic considerations (pistol grip) was tested against a current market tool with a traditional pinch grip handle. The goal of this study is to quantify the impact ergonomic design considerations which have on surgeon performance. We hypothesized that there will be measurable differences between the efficiency while performing FLS surgical trainer tasks when using both tool handle designs in three categories: time to completion, technical skill, and subjective user ratings. The pistol grip incorporates an ergonomic interface intended to reduce contact stress points on the hand and fingers, promote a more neutral operating wrist posture, and reduce hand tremor and fatigue. The traditional pinch grip is a laparoscopic tool developed by Stryker Inc. widely used during minimal invasive surgery. Twenty-three (13 M, 10 F) participants with no existing upper extremity musculoskeletal disorders or experience performing laparoscopic procedures were selected to perform in this study. During a training session prior to testing, participants performed practice trials in a SAGES FLS trainer with both tools. During data collection, participants performed three evaluation tasks using both handle designs (order was randomized, and each trial completed three times). The tasks consisted of FLS peg transfer, cutting, and suturing tasks. Feedback from test participants indicated that they significantly preferred the ergonomic pistol grip in every category (p < 0.05); most notably, participants experienced greater degrees of discomfort in their hands after using the pinch grip tool. Furthermore, participants completed cutting and peg transfer tasks in a shorter time duration (p < 0.05) with the pistol grip than with the pinch grip design; there was no significant difference between completion times for the suturing task. Finally, there was no significant interaction between tool type and errors made during trials. There was a significant preference for as well as lower pain experienced during use of the pistol grip tool as seen from the survey feedback. Both evaluation tasks (cutting and peg transfer) were also completed significantly faster with the pistol grip tool. Finally, due to the high degree of variability in the error data, it was not possible to draw any meaningful conclusions about the effect of tool design on the number or degree of errors made.

  16. Finite Element Simulations for Investigating the Effects of Specimen Geometry in Superplastic Tensile Tests

    NASA Astrophysics Data System (ADS)

    Nazzal, Mohammad; Abu-Farha, Fadi; Curtis, Richard

    2011-08-01

    Characterizing the behavior of superplastic materials is largely based on the uniaxial tensile test; yet the unique nature of these materials requires a particularly tailored testing methodology, different to that used with conventional materials. One of the crucial testing facets is the specimen geometry, which has a great impact on the outcome of a superplastic tensile test, as a result of the associated extreme conditions. And while researchers agree that it should take a notably different form than the typical dog-bone shape; there is no universal agreement on the specimen's particular size and dimensions, as evident by the disparities in test specimens used in the various superplastic testing efforts found throughout the literature. In view of that, this article is dedicated to understanding the effects of specimen geometry on the superplastic behavior of the material during tensile testing. Deformation of the Ti6Al4V titanium alloy is FE simulated based on a multitude of specimen geometries, covering a wide range of gauge length, gauge width, grip length, and grip width values. The study provides key insights on the influences of each geometrical parameter as well as their interactions, and provides recommendations on selecting the specimen's proportions for accurate and unified tensile testing of superplastic materials.

  17. Experimental Study on Strength Evaluation Applied for Teeth Extraction: An In Vivo Study

    PubMed Central

    Cicciù, Marco; Bramanti, Ennio; Signorino, Fabrizio; Cicciù, Alessandra; Sortino, Francesco

    2013-01-01

    Purpose: The aim of this work was to analyse all the applied movements when extracting healthy upper and lower jaw premolars for orthodontic purposes. The authors wanted to demonstrate that the different bone densities of the mandible and maxilla are not a significant parameter when related to the extraction force applied. The buccal and palatal rocking movements, plus the twisting movements were also measured in this in-vivo study during premolar extraction for orthodontic purposes. Methods: The physical strains or forces transferred onto the teeth during extraction are the following three movements: gripping, twisting, and traction. A strain measurement gauge was attached onto an ordinary dentistry plier. The strain measurement gauge was constituted with an extensimetric washer with three 45º grids. The system operation was correlated to the variation of electrical resistance. Results: The variations of resistance (∆R) and all the different forces applied to the teeth (∆V) were recorded by a computerized system. Data results were processed through Microsoft Excel. The results underlined the stress distribution on the extracted teeth during gripping, twisting and flexion. Conclusions: The obtained data showed that the strength required to effect teeth extraction is not influenced by the quality of the bone but is instead influenced by the shape of the tooth’s root. PMID:23539609

  18. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study.

    PubMed

    Bayer, Thomas; Fries, Simon; Schweizer, Andreas; Schöffl, Isabelle; Janka, Rolf; Bongartz, Georg

    2015-01-01

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position.

  19. Validation of a pictorial rating scale for grip strength evaluation in 3- to 6-year-old children.

    PubMed

    Defrasne Ait-Said, Elise; Groslambert, Alain; Courty, Daniel

    2007-06-13

    The present study aimed to validate a pictorial rating scale to evaluate the child's ability to produce grip forces. Thirty-seven children aged 3 to 6 years participated as subjects in this investigation. We used a tailor-made pictorial scale and a hand grip strength meter, as well as a Piaget's clinical interview aimed to gather information on the child's understanding of the rating scale. The sensitivity of the rating scale was measured by testing a 4-intensity-level hand grip effort with 3- to 6-year-old children. In addition, the reproducibility of this pictorial rating scale was investigated by a test and randomised re-test procedure. Statistical analysis revealed that no significant main effect (P>0.05) for test was observed in any child. In addition, no significant main effect (P>0.05) for intensity was found in 3-year-old children. However, in the 4-year-old children and over, a significant main effect (P<0.05) was found for intensity. The results also showed that 5- and 6-year-old children were able to produce four differentiated intensities of grip forces. These findings suggest that the pictorial rating scale for grip strength evaluation showed acceptable reproducibility and was sensitive to the age of the children tested. To conclude, this pictorial rating scale appears to be a valid tool to investigate accurately the child's ability to produce grip forces in young children from 5-year-old and over.

  20. Functional studies in 79-year-olds. II. Upper extremity function.

    PubMed

    Lundgren-Lindquist, B; Sperling, L

    1983-01-01

    As part of the Gerontological and Geriatric Population Study of 79-year-old people in Göteborg, a representative subsample comprising 112 women and 93 men took part in a study of upper extremity function. Thirty-eight per cent of the women and 37% of the men had disorders in the upper extremities. The investigation included tests of co-ordination, static strength in the key-grip and the transversal volar grip, power capacity in opening jars and a bottle, basal movements in the upper extremities in personal hygiene and dressing activities, function in the kitchen e.g. reaching shelves, manual tasks including tests of pronation and supination of the forearm. In the key-grip as well as in the transversal volar grip men showed a generally larger decrease in strength with age than women compared to 70-year-olds in a previous population study. Significant correlations were found between strength in the key-grip and the performance time in the test of co-ordination. Women produced about 66% of the muscular force of the men when opening jars. Significant correlations were found between strength in the transversal volar grip and the maximal torque for opening the jars. Female and male subjects who were not capable of handling the electric plug in the manual ability test had significantly weaker strength in the key-grip. The importance of designing products and adapting the environment so as to correspond to the functional capacity of the elderly, is emphasized.

  1. Age-Related and Sex-Related Differences in Hand and Pinch Grip Strength in Adults

    ERIC Educational Resources Information Center

    Puh, Urska

    2010-01-01

    The purpose of the study was to quantify age-related changes in hand grip strength and three types of pinch grip strength (key pinch, tip pinch, and palmar pinch) among male and female participants. The study included 199 healthy participants (100 females, 99 males) aged 20-79 years, who were divided into four age groups. The Baseline Hydraulic…

  2. GRIP Experiment 2010

    NASA Image and Video Library

    2010-08-15

    The NASA DC-8 airplane sits on the tarmac, Monday, Aug. 16, 2010, at Fort Lauderdale Hollywood International Airport in Fort Lauderdale, Fla. , as preparations continue for its part in the GRIP experiment. The Genesis and Rapid Intensification Processes (GRIP) experiment is a NASA Earth science field experiment in 2010 that is being conducted to better understand how tropical storms form and develop into major hurricanes. Photo Credit: (NASA/Paul E. Alers)

  3. GRIP Experiment 2010

    NASA Image and Video Library

    2010-08-14

    The NASA DC-8 airplane sits on the tarmac, Sunday, Aug. 15, 2010, at Fort Lauderdale International Airport in Fort Lauderdale, Fla. , as preparations continue for its part in the GRIP experiment. The Genesis and Rapid Intensification Processes (GRIP) experiment is a NASA Earth science field experiment in 2010 that is being conducted to better understand how tropical storms form and develop into major hurricanes. Photo Credit: (NASA/Paul E. Alers)

  4. Accuracy and precision of protein-ligand interaction kinetics determined from chemical shift titrations.

    PubMed

    Markin, Craig J; Spyracopoulos, Leo

    2012-12-01

    NMR-monitored chemical shift titrations for the study of weak protein-ligand interactions represent a rich source of information regarding thermodynamic parameters such as dissociation constants (K ( D )) in the micro- to millimolar range, populations for the free and ligand-bound states, and the kinetics of interconversion between states, which are typically within the fast exchange regime on the NMR timescale. We recently developed two chemical shift titration methods wherein co-variation of the total protein and ligand concentrations gives increased precision for the K ( D ) value of a 1:1 protein-ligand interaction (Markin and Spyracopoulos in J Biomol NMR 53: 125-138, 2012). In this study, we demonstrate that classical line shape analysis applied to a single set of (1)H-(15)N 2D HSQC NMR spectra acquired using precise protein-ligand chemical shift titration methods we developed, produces accurate and precise kinetic parameters such as the off-rate (k ( off )). For experimentally determined kinetics in the fast exchange regime on the NMR timescale, k ( off ) ~ 3,000 s(-1) in this work, the accuracy of classical line shape analysis was determined to be better than 5 % by conducting quantum mechanical NMR simulations of the chemical shift titration methods with the magnetic resonance toolkit GAMMA. Using Monte Carlo simulations, the experimental precision for k ( off ) from line shape analysis of NMR spectra was determined to be 13 %, in agreement with the theoretical precision of 12 % from line shape analysis of the GAMMA simulations in the presence of noise and protein concentration errors. In addition, GAMMA simulations were employed to demonstrate that line shape analysis has the potential to provide reasonably accurate and precise k ( off ) values over a wide range, from 100 to 15,000 s(-1). The validity of line shape analysis for k ( off ) values approaching intermediate exchange (~100 s(-1)), may be facilitated by more accurate K ( D ) measurements from NMR-monitored chemical shift titrations, for which the dependence of K ( D ) on the chemical shift difference (Δω) between free and bound states is extrapolated to Δω = 0. The demonstrated accuracy and precision for k ( off ) will be valuable for the interpretation of biological kinetics in weakly interacting protein-protein networks, where a small change in the magnitude of the underlying kinetics of a given pathway may lead to large changes in the associated downstream signaling cascade.

  5. Energy efficiency analysis of the manipulation process by the industrial objects with the use of Bernoulli gripping devices

    NASA Astrophysics Data System (ADS)

    Savkiv, Volodymyr; Mykhailyshyn, Roman; Duchon, Frantisek; Mikhalishin, Mykhailo

    2017-11-01

    The article deals with the topical issue of reducing energy consumption for transportation of industrial objects. The energy efficiency of the process of objects manipulation with the use of the orientation optimization method while gripping with the help of different methods has been studied. The analysis of the influence of the constituent parts of inertial forces, that affect the object of manipulation, on the necessary force characteristics and energy consumption of Bernoulli gripping device has been proposed. The economic efficiency of the use of the optimal orientation of Bernoulli gripping device while transporting the object of manipulation in comparison to the transportation without re-orientation has been proved.

  6. Self-gripping mesh versus fibrin glue fixation in laparoscopic inguinal hernia repair: a randomized prospective clinical trial in young and elderly patients

    PubMed Central

    Bindi, Marco; Rivelli, Matteo; Solej, Mario; Enrico, Stefano; Martino, Valter

    2016-01-01

    Abstract Laparoscopic transabdominal preperitoneal inguinal hernia repair is a safe and effective technique. In this study we tested the hypothesis that self-gripping mesh used with the laparoscopic approach is comparable to polypropylene mesh in terms of perioperative complications, against a lower overall cost of the procedure. We carried out a prospective randomized trial comparing a group of 30 patients who underwent laparoscopic inguinal hernia repair with self-gripping mesh versus a group of 30 patients who received polypropylene mesh with fibrin glue fixation. There were no statistically significant differences between the two groups with regard to intraoperative variables, early or late intraoperative complications, chronic pain or recurrence. Self-gripping mesh in transabdominal hernia repair was found to be a valid alternative to polypropylene mesh in terms of complications, recurrence and postoperative pain. The cost analysis and comparability of outcomes support the preferential use of self-gripping mesh. PMID:28352842

  7. The transcriptional coregulator GRIP1 controls macrophage polarization and metabolic homeostasis

    PubMed Central

    Coppo, Maddalena; Chinenov, Yurii; Sacta, Maria A.; Rogatsky, Inez

    2016-01-01

    Diet-induced obesity causes chronic macrophage-driven inflammation in white adipose tissue (WAT) leading to insulin resistance. WAT macrophages, however, differ in their origin, gene expression and activities: unlike infiltrating monocyte-derived inflammatory macrophages, WAT-resident macrophages counteract inflammation and insulin resistance, yet, the mechanisms underlying their transcriptional programming remain poorly understood. We recently reported that a nuclear receptor cofactor—glucocorticoid receptor (GR)-interacting protein (GRIP)1—cooperates with GR to repress inflammatory genes. Here, we show that GRIP1 facilitates macrophage programming in response to IL4 via a GR-independent pathway by serving as a coactivator for Kruppel-like factor (KLF)4—a driver of tissue-resident macrophage differentiation. Moreover, obese mice conditionally lacking GRIP1 in macrophages develop massive macrophage infiltration and inflammation in metabolic tissues, fatty livers, hyperglycaemia and insulin resistance recapitulating metabolic disease. Thus, GRIP1 is a critical regulator of immunometabolism, which engages distinct transcriptional mechanisms to coordinate the balance between macrophage populations and ultimately promote metabolic homeostasis. PMID:27464507

  8. Wearable flex sensor system for multiple badminton player grip identification

    NASA Astrophysics Data System (ADS)

    Jacob, Alvin; Zakaria, Wan Nurshazwani Wan; Tomari, Mohd Razali Bin Md; Sek, Tee Kian; Suberi, Anis Azwani Muhd

    2017-09-01

    This paper focuses on the development of a wearable sensor system to identify the different types of badminton grip that is used by a player during training. Badminton movements and strokes are fast and dynamic, where most of the involved movement are difficult to identify with the naked eye. Also, the usage of high processing optometric motion capture system is expensive and causes computational burden. Therefore, this paper suggests the development of a sensorized glove using flex sensor to measure a badminton player's finger flexion angle. The proposed Hand Monitoring Module (HMM) is connected to a personal computer through Bluetooth to enable wireless data transmission. The usability and feasibility of the HMM to identify different grip types were examined through a series of experiments, where the system exhibited 70% detection ability for the five different grip type. The outcome plays a major role in training players to use the proper grips for a badminton stroke to achieve a more powerful and accurate stroke execution.

  9. Interaction in planning vocalizations and grasping.

    PubMed

    Tiainen, Mikko; Tiippana, Kaisa; Vainio, Martti; Komeilipoor, Naeem; Vainio, Lari

    2017-08-01

    Previous studies have shown a congruency effect between manual grasping and syllable articulation. For instance, a power grip is associated with syllables whose articulation involves the tongue body and/or large mouth aperture ([kɑ]) whereas a precision grip is associated with articulations that involve the tongue tip and/or small mouth aperture ([ti]). Previously, this effect has been observed in manual reaction times. The primary aim of the current study was to investigate whether this congruency effect also takes place in vocal responses and to investigate involvement of action selection processes in the effect. The congruency effect was found in vocal and manual responses regardless of whether or not the syllable or grip was known a priori, suggesting that the effect operates with minimal or absent action selection processes. In addition, the effect was observed in vocal responses even when the grip was only prepared but not performed, suggesting that merely planning a grip response primes the corresponding articulatory response. These results support the view that articulation and grasping are processed in a partially overlapping network.

  10. Strain E?ect on the Instability of Island Formation in Submonolayer Heteroepitaxy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yao, yugui; Li, Maozhi; Wu, Biao

    2009-01-01

    Strain e ect on the instability of island formation in submonolayer heteroepitaxy is studied in both thermodynamic and kinetic regimes. By using linear stability analysis, the energy change of an island due to small perturbations is analyzed. A phase diagram is constructed to illustrate the interplay between kinetic processes and strain e ect on the shape instability. Critical island sizes beyond which islands grow unstable are also derived for various growth conditions and can be used to estimate energy parameters. The scaling forms of shape instability are also discussed.

  11. Sex Differences in Fear of Falling among Older Adults with Low Grip Strength.

    PubMed

    Lim, Eunju

    2016-05-01

    Fear of falling is not only a risk factor for falls, but it is also an important clinical predictor of functional decline in older adults. This study identified sex differences in fear of falling and related factors in older adults with low grip strength. The data of 902 older adults from the 2012 Korean National Survey, conducted as a research project by the Korea Employment Information Service, were analyzed. Grip strength, activities of daily living, cognitive function, depressive symptoms, and fear of falling were assessed. Multiple regression analysis was performed by a simultaneous data entry method. Fear of falling was greater in older women with low grip strength than in their male equivalents (P<0.001). Regression analysis showed that age, fall experience within the previous 2 yr, activities of daily living, and depressive symptoms collectively accounted for 15.3% (P<0.001) of the variance among men. Meanwhile, age, fall experience within the previous 2 yr, grip strength, activities of daily living, and depressive symptoms collectively accounted for 13.4% (P<0.001) of the variance among women. Thus, the predictors of fear of falling differ between older men and women with low grip strength. Therefore, sex differences must be considered when developing intervention strategies for reducing fear of falling in this demographic.

  12. Early reduction in toe flexor strength is associated with physical activity in elderly men.

    PubMed

    Suwa, Masataka; Imoto, Takayuki; Kida, Akira; Yokochi, Takashi

    2016-05-01

    [Purpose] To compare the toe flexor, hand grip and knee extensor strengths of young and elderly men, and to examine the association between toe flexor strength and physical activity or inactivity levels. [Subjects and Methods] Young (n=155, 18-23 years) and elderly (n=60, 65-88 years) men participated in this study. Toe flexor, hand grip, and knee extensor strength were measured. Physical activity (time spent standing/walking per day) and inactivity (time spent sitting per day) were assessed using a self-administered questionnaire. [Results] Toe flexor, hand grip, and knee extensor strength of the elderly men were significantly lower than those of the young men. Standing/walking and sitting times of the elderly men were lower than those of the young men. Toe flexor strength correlated with hand grip and knee extensor strength in both groups. In elderly men, toe flexor strength correlated with standing/walking time. In comparison to the young men's mean values, toe flexor strength was significantly lower than knee extensor and hand grip strength in the elderly group. [Conclusion] The results suggest that age-related reduction in toe flexor strength is greater than those of hand grip and knee extensor strengths. An early loss of toe flexor strength is likely associated with reduced physical activity in elderly men.

  13. The interdigital brace and other grips for termite nest perforation by chimpanzees of the Goualougo Triangle, Republic of Congo.

    PubMed

    Lesnik, Julie J; Sanz, Crickette M; Morgan, David B

    2015-06-01

    Studies of chimpanzee termite foraging enlighten our understanding of early hominin tool use not only by modeling the cognitive ability of our ancestors but also by emphasizing the possible role of social insects in the hominin diet. The chimpanzees of the Goualougo Triangle are known to have one of the largest and most complex tool repertoires reported for wild chimpanzees. One tool set habitually used by this population includes a perforating tool to penetrate the hard outer crust of elevated termite nests before fishing for termite prey with an herbaceous stem. Here, we report the variation present in the grips used on the perforating tool. Our analysis of video recordings of chimpanzee visitation to termite nests over a 3-year period shows that these chimpanzees use a variety of grips to navigate the challenges encountered in opening a termite nest. For situations in which the soil is most hardened, perforating requires force and a power grip is often used. When the soil in the passageway is loose, precision grips are suitable for the task. One of the preferred grips reported here is an interdigital brace, which has previously been described in studies of how some people hold a pencil. In this study, for the first time, the interdigital brace has been thoroughly described for chimpanzees. The various strategies and grips used during perforation emphasize the importance of termites as a nutritional resource that should be considered more strongly as a food used by early hominins. © 2015 Wiley Periodicals, Inc.

  14. Functional Status Modifies the Association of Blood Pressure with Death in Elders: Health and Retirement Study.

    PubMed

    Wu, Chenkai; Smit, Ellen; Peralta, Carmen A; Sarathy, Harini; Odden, Michelle C

    2017-07-01

    To examine whether grip strength, gait speed, and the combination of the two physical functioning measures modified the association of systolic BP (SBP) and diastolic BP (DBP) with mortality. Nationally representative cohort study. Health and Retirement Study. 7,492 U.S. adults aged ≥65 years. Grip strength was measured by a hand dynamometer and classified as normal (≥16 kg for female; ≥26 kg for male) and weak. Gait speed was assessed over a 98.5-inch walk and classified as non-slow (≥0.60 m/s for female; ≥0.52 m/s for male) and slow. Over an average follow-up time of 6.0 years, 1,870 (25.0%) participants died. After adjustment for socio-demographic, behavioral, and clinical measures, elevated SBP (≥150 mmHg) and DBP (≥90 mmHg) was associated with a 24% (95% CI, 7-43%) and 25% (95% CI, 5-49%) higher mortality among participants with normal grip strength. In contrast, elevated SBP and DBP was associated with a 6% (95% CI, 31 to -27%) and a 16% (95% CI, 46 to -26%) lower mortality among those with weak grip strength (P-values of interactions: both=.07). The inverse relations between BP with death were most pronounced among slow walkers with weak grip strength. The HRs of elevated SBP and DBP for death was 0.85 (95% CI, 0.56-1.29) and 0.53 (95% CI, 0.30-0.96), respectively, and was substantially different from non-slow walkers with normal grip strength (HR = 1.24 and 1.15, respectively; P-values of interactions: both <.001). Therefore, associations of BP with death varied modestly by gait speed. Grip strength modified the association of BP with death. Combination of grip strength and gait speed has incremental value for modifying the association of BP with death. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.

  15. Grip strength as a frailty diagnostic component in geriatric inpatients.

    PubMed

    Dudzińska-Griszek, Joanna; Szuster, Karolina; Szewieczek, Jan

    2017-01-01

    Frailty has emerged as a key medical syndrome predictive of comorbidity, disability, institutionalization and death. As a component of the five frailty phenotype diagnostic criteria, patient grip strength deserves attention as a simple and objective measure of the frailty syndrome. The aim of this study was to assess conditions that influence grip strength in geriatric inpatients. The study group consisted of 80 patients aged 78.6±7.0 years [Formula: see text], with 68.8% women, admitted to the Department of Geriatrics. A comprehensive geriatric assessment was complemented with assessment for the frailty phenotype as described by Fried et al for all patients in the study group. Functional assessment included Barthel Index of Activities of Daily Living (Barthel Index), Instrumental Activities of Daily Living Scale and Mini-Mental State Examination. Three or more frailty criteria were positive in 32 patients (40%), while 56 subjects (70%) fulfilled the frailty criterion of weakness (grip strength test). Multivariate linear regression analysis revealed that two independent measures showed positive association with grip strength - Mini-Mental State Examination score (β=0.239; P =0.001) and statin use (β=0.213; P =0.002) - and four independent measures were negatively associated with grip strength - female sex (β=-0.671; P <0.001), C-reactive protein (β=-0.253; P <0.001), prior myocardial infarction (β=-0.190; P =0.006) and use of an antidepressant (β=-0.163; P =0.018). Low physical activity was identified as the only independent qualitative frailty component associated with 2-year mortality in multivariate logistic regression analysis after adjustment for age and sex (odds ratio =6.000; 95% CI =1.357-26.536; P =0.018). Cognitive function, somatic comorbidity and medical treatment affect grip strength as a measure of physical frailty in geriatric inpatients. Grip strength was not predictive of 2-year mortality in this group.

  16. Birth weight, intrauterine growth restriction and nutritional status in childhood in relation to grip strength in adults: from the 1982 Pelotas (Brazil) birth cohort.

    PubMed

    Bielemann, Renata Moraes; Gigante, Denise Petrucci; Horta, Bernardo Lessa

    2016-02-01

    The aim of this study was to evaluate the association among birth weight, intrauterine growth, and nutritional status in childhood with grip strength in young adults from the 1982 Pelotas (Brazil) birth cohort. In 1982, the hospital live births of Pelotas were followed. In 2012, grip strength was evaluated using a hand dynamometer and the best of the six measurements was used. Birth weight was analyzed as z-score for gestational age according to Williams (1982) curve. Weight-for-age, weight-for-length/height, and length/height-for-age at 2 and 4 y were analyzed in z-scores according to 2006 World Health Organization Child Growth Standards. Lean mass at 30 y was included as possible mediator using the g-computation formula. In 2012, 3701 (68.1%) individuals were interviewed and 3470 were included in the present analyses. An increase of 1 z-score in birth weight was associated with an increase of 1.5 kg in grip strength in males (95% confidence interval, 1.1-1.9). Positive effect of birth weight on grip strength was found in females. Grip strength was greater in individuals who were born with appropriate size for gestational age and positively associated with weight- and length/height-for-age z-score at 2 and 4 y of age. A positive association between birth weight and grip strength was only partially mediated by adult lean mass (50% and 33% of total effect in males and females), whereas direct effect of weight at 2 y was found only in males. It is suggested that good nutrition in prenatal and early postnatal life has a positive influence on adult muscle strength. The results from birth weight were suggestive of fetal programming on grip strength measurement. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  17. On the kinetic and equilibrium shapes of icosahedral Al 71Pd 19Mn 10 quasicrystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Senabulya, Nancy; Xiao, Xianghui; Han, Insung

    The dynamics of growth and relaxation of icosahedral single quasicrystals in a liquid phase were investigated using in situ synchrotron-based X-ray tomography. Here, our 4D studies (i.e., space- and time-resolved) provide direct evidence that indicates the growth process of an Al 71Pd 19Mn 10 quasicrystal is governed predominantly by bulk transport rather than attachment kinetics. This work is in agreement with theoretical predictions, which show that the pentagonal dodecahedron is not the minimum energy structure in Al-Pd-Mn icosahedral quasicrystals, but merely a growth shape characterized by non-zero anisotropic velocity. This transient shape transforms into a truncated dodecahedral Archimedian polyhedron oncemore » equilibrium has been attained.« less

  18. On the kinetic and equilibrium shapes of icosahedral Al 71Pd 19Mn 10 quasicrystals

    DOE PAGES

    Senabulya, Nancy; Xiao, Xianghui; Han, Insung; ...

    2018-03-06

    The dynamics of growth and relaxation of icosahedral single quasicrystals in a liquid phase were investigated using in situ synchrotron-based X-ray tomography. Here, our 4D studies (i.e., space- and time-resolved) provide direct evidence that indicates the growth process of an Al 71Pd 19Mn 10 quasicrystal is governed predominantly by bulk transport rather than attachment kinetics. This work is in agreement with theoretical predictions, which show that the pentagonal dodecahedron is not the minimum energy structure in Al-Pd-Mn icosahedral quasicrystals, but merely a growth shape characterized by non-zero anisotropic velocity. This transient shape transforms into a truncated dodecahedral Archimedian polyhedron oncemore » equilibrium has been attained.« less

  19. Control of DNA-Functionalized Nanoparticle Assembly

    NASA Astrophysics Data System (ADS)

    Olvera de La Cruz, Monica

    Directed crystallization of a large variety of nanoparticles, including proteins, via DNA hybridization kinetics has led to unique materials with a broad range of crystal symmetries. The nanoparticles are functionalized with DNA chains that link neighboring functionalized units. The shape of the nanoparticle, the DNA length, the sequence of the hybridizing DNA linker and the grafting density determine the crystal symmetries and lattice spacing. By carefully selecting these parameters one can, in principle, achieve all the symmetries found for both atomic and colloidal crystals of asymmetric shapes as well as new symmetries, and drive transitions between them. A scale-accurate coarse-grained model with explicit DNA chains provides the design parameters, including degree of hybridization, to achieve specific crystal structures. The model also provides surface energy values to determine the shape of defect-free single crystals with macroscopic anisotropic properties, as well as the parameters to develop colloidal models that reproduce both the shape of single crystals and their growth kinetics.

  20. Dendritic growth shapes in kinetic Monte Carlo models

    NASA Astrophysics Data System (ADS)

    Krumwiede, Tim R.; Schulze, Tim P.

    2017-02-01

    For the most part, the study of dendritic crystal growth has focused on continuum models featuring surface energies that yield six pointed dendrites. In such models, the growth shape is a function of the surface energy anisotropy, and recent work has shown that considering a broader class of anisotropies yields a correspondingly richer set of growth morphologies. Motivated by this work, we generalize nanoscale models of dendritic growth based on kinetic Monte Carlo simulation. In particular, we examine the effects of extending the truncation radius for atomic interactions in a bond-counting model. This is done by calculating the model’s corresponding surface energy and equilibrium shape, as well as by running KMC simulations to obtain nanodendritic growth shapes. Additionally, we compare the effects of extending the interaction radius in bond-counting models to that of extending the number of terms retained in the cubic harmonic expansion of surface energy anisotropy in the context of continuum models.

  1. The role of nanopore shape in surface-induced crystallization

    NASA Astrophysics Data System (ADS)

    Diao, Ying; Harada, Takuya; Myerson, Allan S.; Alan Hatton, T.; Trout, Bernhardt L.

    2011-11-01

    Crystallization of a molecular liquid from solution often initiates at solid-liquid interfaces, and nucleation rates are generally believed to be enhanced by surface roughness. Here we show that, on a rough surface, the shape of surface nanopores can also alter nucleation kinetics. Using lithographic methods, we patterned polymer films with nanopores of various shapes and found that spherical nanopores 15-120 nm in diameter hindered nucleation of aspirin crystals, whereas angular nanopores of the same size promoted it. We also show that favourable surface-solute interactions are required for angular nanopores to promote nucleation, and propose that pore shape affects nucleation kinetics through the alteration of the orientational order of the crystallizing molecule near the angles of the pores. Our findings have clear technological implications, for instance in the control of pharmaceutical polymorphism and in the design of ‘seed’ particles for the regulation of crystallization of fine chemicals.

  2. Kinetic analysis of concurrent activation potentiation during back squats and jump squats.

    PubMed

    Ebben, William P; Kaufmann, Clare E; Fauth, McKenzie L; Petushek, Erich J

    2010-06-01

    Concurrent activation potentiation enhances muscular force during open kinetic chain isometric and isokinetic exercises via remote voluntary contractions (RVCs). The purpose of this study was to evaluate the effect of RVCs on the performance of closed kinetic chain ground-based exercises. Subjects included 13 men (21.4+/-1.5 years) who performed the back squat and jump squat in 2 test conditions. The RVC condition included performing the test exercises while clenching the jaw on a mouth guard, forcefully gripping and pulling the barbell down into the trapezius, and performing a Valsalva maneuver. The normal condition (NO-RVC) included performing the test exercises without RVCs. Exercises were assessed with a force platform. Peak ground reaction force (GRF), rate of force development (RFD) during the first 100 milliseconds (RFD-100), RFD to peak GRF (RFD-P), and jump squat height (JH) were calculated from the force-time records. Data were analyzed using an analysis of variance. Results reveal that GRF and RFD-100 were higher in the RVC compared with the NO-RVC condition for both the back squat and jump squat (p

  3. Visual evaluation of kinetic characteristics of PET probe for neuroreceptors using a two-phase graphic plot analysis.

    PubMed

    Ito, Hiroshi; Ikoma, Yoko; Seki, Chie; Kimura, Yasuyuki; Kawaguchi, Hiroshi; Takuwa, Hiroyuki; Ichise, Masanori; Suhara, Tetsuya; Kanno, Iwao

    2017-05-01

    Objectives In PET studies for neuroreceptors, tracer kinetics are described by the two-tissue compartment model (2-TCM), and binding parameters, including the total distribution volume (V T ), non-displaceable distribution volume (V ND ), and binding potential (BP ND ), can be determined from model parameters estimated by kinetic analysis. The stability of binding parameter estimates depends on the kinetic characteristics of radioligands. To describe these kinetic characteristics, we previously developed a two-phase graphic plot analysis in which V ND and V T can be estimated from the x-intercept of regression lines for early and delayed phases, respectively. In this study, we applied this graphic plot analysis to visual evaluation of the kinetic characteristics of radioligands for neuroreceptors, and investigated a relationship between the shape of these graphic plots and the stability of binding parameters estimated by the kinetic analysis with 2-TCM in simulated brain tissue time-activity curves (TACs) with various binding parameters. Methods 90-min TACs were generated with the arterial input function and assumed kinetic parameters according to 2-TCM. Graphic plot analysis was applied to these simulated TACs, and the curvature of the plot for each TAC was evaluated visually. TACs with several noise levels were also generated with various kinetic parameters, and the bias and variation of binding parameters estimated by kinetic analysis were calculated in each TAC. These bias and variation were compared with the shape of graphic plots. Results The graphic plots showed larger curvature for TACs with higher specific binding and slower dissociation of specific binding. The quartile deviations of V ND and BP ND determined by kinetic analysis were smaller for radioligands with slow dissociation. Conclusions The larger curvature of graphic plots for radioligands with slow dissociation might indicate a stable determination of V ND and BP ND by kinetic analysis. For investigation of the kinetics of radioligands, such kinetic characteristics should be considered.

  4. Case-study of a user-driven prosthetic arm design: bionic hand versus customized body-powered technology in a highly demanding work environment.

    PubMed

    Schweitzer, Wolf; Thali, Michael J; Egger, David

    2018-01-03

    Prosthetic arm research predominantly focuses on "bionic" but not body-powered arms. However, any research orientation along user needs requires sufficiently precise workplace specifications and sufficiently hard testing. Forensic medicine is a demanding environment, also physically, also for non-disabled people, on several dimensions (e.g., distances, weights, size, temperature, time). As unilateral below elbow amputee user, the first author is in a unique position to provide direct comparison of a "bionic" myoelectric iLimb Revolution (Touch Bionics) and a customized body-powered arm which contains a number of new developments initiated or developed by the user: (1) quick lock steel wrist unit; (2) cable mount modification; (3) cast shape modeled shoulder anchor; (4) suspension with a soft double layer liner (Ohio Willowwood) and tube gauze (Molnlycke) combination. The iLimb is mounted on an epoxy socket; a lanyard fixed liner (Ohio Willowwood) contains magnetic electrodes (Liberating Technologies). An on the job usage of five years was supplemented with dedicated and focused intensive two-week use tests at work for both systems. The side-by-side comparison showed that the customized body-powered arm provides reliable, comfortable, effective, powerful as well as subtle service with minimal maintenance; most notably, grip reliability, grip force regulation, grip performance, center of balance, component wear down, sweat/temperature independence and skin state are good whereas the iLimb system exhibited a number of relevant serious constraints. Research and development of functional prostheses may want to focus on body-powered technology as it already performs on manually demanding and heavy jobs whereas eliminating myoelectric technology's constraints seems out of reach. Relevant testing could be developed to help expediting this. This is relevant as Swiss disability insurance specifically supports prostheses that enable actual work integration. Myoelectric and cosmetic arm improvement may benefit from a less forgiving focus on perfecting anthropomorphic appearance.

  5. GRIP Experiment 2010

    NASA Image and Video Library

    2017-12-08

    The NASA DC-8 airplane sits on the tarmac, Sunday, Aug. 15, 2010, at Fort Lauderdale International Airport in Fort Lauderdale, Fla. , as preparations continue for its part in the GRIP experiment. The Genesis and Rapid Intensification Processes (GRIP) experiment is a NASA Earth science field experiment in 2010 that is being conducted to better understand how tropical storms form and develop into major hurricanes. Credit: NASA/Paul E. Alers To read more about the GRIP Mission go here or here for an interactive feature NASA Goddard Space Flight Center is home to the nation's largest organization of combined scientists, engineers and technologists that build spacecraft, instruments and new technology to study the Earth, the sun, our solar system, and the universe. Follow us on Twitter Join us on Facebook

  6. Robot Hand Grips Cylinders Securely

    NASA Technical Reports Server (NTRS)

    Parma, George F.

    1989-01-01

    Jaws and linkage accommodate various sizes. Robot hand includes two pairs of parallel jaws that grasp rods, pipes, tubes, struts, and other long, heavy cylindrical objects. Hand features compact rotary drive and butterfly configuration simplifying approach and gripping maneuvers of robot. Parallelogram linkages maintain alignment of each jaw with other jaws. One bar of each linkage connected to one of two concentric, counterrotating shafts; rotation of shafts moves jaws in each pair toward or away from each other to grasp or release workpiece. Each jaw includes rigid gripping pad lined with rubber to give firm grip and to prevent damage to workpiece. Inner cylindrical surface (corner) of each jaw tapers off to flat sides. Enables jaw to grasp workpieces with diameters larger than or equal to twice the corner radius.

  7. Shape transition of endotaxial islands growth from kinetically constrained to equilibrium regimes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhi-Peng, E-mail: LI.Zhipeng@nims.go.jp; Global Research Center for Environment and Energy based on Nanomaterials Science, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044; Tok, Engsoon

    2013-09-01

    Graphical abstract: - Highlights: • All Fe{sub 13}Ge{sub 8} islands will grow into Ge(0 0 1) substrate at temperatures from 350 to 675 °C. • Shape transition occurred from kinetically constrained to equilibrium regime. • All endotaxial islands can be clarified into two types. • The mechanisms of endotaxial growth and shape transition have been rationalized. - Abstract: A comprehensive study of Fe grown on Ge(0 0 1) substrates has been conducted at elevated temperatures, ranging from 350 to 675 °C. All iron germinide islands, with the same Fe{sub 13}Ge{sub 8} phase, grow into the Ge substrate with the samemore » epitaxial relationship. Shape transition occurs from small square islands (low temperatures), to elongated orthogonal islands or orthogonal nanowires (intermediate temperatures), and then finally to large square orthogonal islands (high temperatures). According to both transmission electron microscopy (TEM) and atomic force microscopy (AFM) investigations, all islands can be defined as either type-I or type-II. Type-I islands usually form at kinetically constrained growth regimes, like truncated pyramids. Type-II islands usually appear at equilibrium growth regimes forming a dome-like shape. Based on a simple semi-quantitative model, type-II islands have a lower total energy per volume than type-I, which is considered as the dominant mechanism for this type of shape transition. Moreover, this study not only elucidates details of endotaxial growth in the Fe–Ge system, but also suggests the possibility of controlled fabrication of temperature-dependent nanostructures, especially in materials with dissimilar crystal structures.« less

  8. Structural Conversion of Aβ17–42 Peptides from Disordered Oligomers to U-Shape Protofilaments via Multiple Kinetic Pathways

    PubMed Central

    Cheon, Mookyung; Hall, Carol K.; Chang, Iksoo

    2015-01-01

    Discovering the mechanisms by which proteins aggregate into fibrils is an essential first step in understanding the molecular level processes underlying neurodegenerative diseases such as Alzheimer’s and Parkinson's. The goal of this work is to provide insights into the structural changes that characterize the kinetic pathways by which amyloid-β peptides convert from monomers to oligomers to fibrils. By applying discontinuous molecular dynamics simulations to PRIME20, a force field designed to capture the chemical and physical aspects of protein aggregation, we have been able to trace out the entire aggregation process for a system containing 8 Aβ17–42 peptides. We uncovered two fibrillization mechanisms that govern the structural conversion of Aβ17–42 peptides from disordered oligomers into protofilaments. The first mechanism is monomeric conversion templated by a U-shape oligomeric nucleus into U-shape protofilament. The second mechanism involves a long-lived and on-pathway metastable oligomer with S-shape chains, having a C-terminal turn, en route to the final U-shape protofilament. Oligomers with this C-terminal turn have been regarded in recent experiments as a major contributing element to cell toxicity in Alzheimer’s disease. The internal structures of the U-shape protofilaments from our PRIME20/DMD simulation agree well with those from solid state NMR experiments. The approach presented here offers a simple molecular-level framework to describe protein aggregation in general and to visualize the kinetic evolution of a putative toxic element in Alzheimer’s disease in particular. PMID:25955249

  9. Artificially-induced organelles are optimal targets for optical trapping experiments in living cells

    PubMed Central

    López-Quesada, C.; Fontaine, A.-S.; Farré, A.; Joseph, M.; Selva, J.; Egea, G.; Ludevid, M. D.; Martín-Badosa, E.; Montes-Usategui, M.

    2014-01-01

    Optical trapping supplies information on the structural, kinetic or rheological properties of inner constituents of the cell. However, the application of significant forces to intracellular objects is notoriously difficult due to a combination of factors, such as the small difference between the refractive indices of the target structures and the cytoplasm. Here we discuss the possibility of artificially inducing the formation of spherical organelles in the endoplasmic reticulum, which would contain densely packed engineered proteins, to be used as optimized targets for optical trapping experiments. The high index of refraction and large size of our organelles provide a firm grip for optical trapping and thereby allow us to exert large forces easily within safe irradiation limits. This has clear advantages over alternative probes, such as subcellular organelles or internalized synthetic beads. PMID:25071944

  10. [An experimental study of effects of active-heating-system for extravehicular spacesuit gloves on working performance].

    PubMed

    Ding, Li; Han, Long-zhu; Yang, Chun-xin; Yang, Feng; Yuan, Xiu-gan

    2005-02-01

    To observe the effects of active heating system for spacesuit gloves on extravehicular working performance. After analyzing the factors with gloves influence on the working performance, the effects of active heating system for gloves were studied experimentally with aspects to fatigue, hand strength, dexterity and tactile sensing. 1) Heating-system had not influence to grip; 2) Heating-system had 17% influence to fatigue except specific person; 3) Nut assembly and nipping pin showed that heating-system had little influence to dexterity; 4) Apperceiving shape of object and two-point distance showed heating-system had little influence to tactility. The active heating method is rational and has little influence on working performance.

  11. Static tensile and tensile creep testing of four boron nitride coated ceramic fibers at elevated temperatures

    NASA Technical Reports Server (NTRS)

    Coguill, Scott L.; Adams, Donald F.; Zimmerman, Richard S.

    1989-01-01

    Six types of uncoated ceramic fibers were static tensile and tensile creep tested at various elevated temperatures. Three types of boron nitride coated fibers were also tested. Room temperature static tensile tests were initially performed on all fibers, at gage lengths of 1, 2, and 4 inches, to determine the magnitude of end effects from the gripping system used. Tests at one elevated temperature, at gage lengths of 8 and 10 inches, were also conducted, to determine end effects at elevated temperatures. Fiber cross sectional shapes and areas were determined using scanning electron microscopy. Creep testing was typically performed for 4 hours, in an air atmosphere.

  12. Development of multichannel soft tactile sensors having fingerprint structure.

    PubMed

    Tsutsui, H; Murashima, Y; Honma, N; Kobayashi, K

    2014-01-01

    It is possible to accurately recognize the shape of an object or to grip it by setting soft tactile sensors on a robot's hands. We studied a multichannel soft tactile sensor as an artificial hand and evaluated the pressure's response performance from several directions and the slipping and sliding responses. The tactile sensor consisted of multiple pneumatic sensors and a soft cap with a fingerprint structure that was made of silicone gum and was separated from multiple spaces. Evaluation tests showed that the multiple soft tactile sensors estimate both an object's contact force and its contact location. Our tactile sensor also measured the object's roughness by the slide on surface texture.

  13. Growth kinetics of disk-shaped copper islands in electrochemical deposition.

    PubMed

    Guo, Lian; Zhang, Shouliang; Searson, Peter

    2009-05-01

    The ability to independently dictate the shape and crystal orientation of islands in electrocrystallization remains a significant challenge. The main reason for this is that the complex interplay between the substrate, nucleation, and surface chemistry is not fully understood. Here we report on the kinetics of island growth for copper on ruthenium oxide. The small nucleation overpotential leads to enhanced lateral growth and the formation of hexagonal disk-shaped islands. The amorphous substrate allows the nuclei to achieve the thermodynamically favorable orientation, i.e., a 111 surface normal. Island growth follows power law kinetics in both lateral and vertical directions. At shorter times, the two growth exponents are equal to 1/2 whereas at longer times lateral growth slows down while vertical growth speeds up. We propose a growth mechanism, wherein the lateral growth of disk-shaped islands is initiated by attachment of Cu adatoms on the ruthenium oxide surface onto the island periphery while vertical growth is initiated by two-dimensional nucleation on the top terrace and followed by lateral step propagation. These results indicate three criteria for enhanced lateral growth in electrodeposition: (i) a substrate that leads to a small nucleation overpotential, (ii) fast adatom surface diffusion on substrate to promote lateral growth, and (iii) preferential anion adsorption to stabilize the basal plane.

  14. Power hand tool kinetics associated with upper limb injuries in an automobile assembly plant.

    PubMed

    Ku, Chia-Hua; Radwin, Robert G; Karsh, Ben-Tzion

    2007-06-01

    This study investigated the relationship between pneumatic nutrunner handle reactions, workstation characteristics, and prevalence of upper limb injuries in an automobile assembly plant. Tool properties (geometry, inertial properties, and motor characteristics), fastener properties, orientation relative to the fastener, and the position of the tool operator (horizontal and vertical distances) were measured for 69 workstations using 15 different pneumatic nutrunners. Handle reaction response was predicted using a deterministic mechanical model of the human operator and tool that was previously developed in our laboratory, specific to the measured tool, workstation, and job factors. Handle force was a function of target torque, tool geometry and inertial properties, motor speed, work orientation, and joint hardness. The study found that tool target torque was not well correlated with predicted handle reaction force (r=0.495) or displacement (r=0.285). The individual tool, tool shape, and threaded fastener joint hardness all affected predicted forces and displacements (p<0.05). The average peak handle force and displacement for right-angle tools were twice as great as pistol grip tools. Soft-threaded fastener joints had the greatest average handle forces and displacements. Upper limb injury cases were identified using plant OSHA 200 log and personnel records. Predicted handle forces for jobs where injuries were reported were significantly greater than those jobs free of injuries (p<0.05), whereas target torque and predicted handle displacement did not show statistically significant differences. The study concluded that quantification of handle reaction force, rather than target torque alone, is necessary for identifying stressful power hand tool operations and for controlling exposure to forces in manufacturing jobs involving power nutrunners. Therefore, a combination of tool, work station, and task requirements should be considered.

  15. Criterion-Referenced Values of Grip Strength and Usual Gait Speed Using Instrumental Activities of Daily Living Disability as the Criterion.

    PubMed

    Lee, Meng-Chih; Hsu, Chih-Cheng; Tsai, Yi-Fen; Chen, Ching-Yu; Lin, Cheng-Chieh; Wang, Ching-Yi

    Current evidence suggests that grip strength and usual gait speed (UGS) are important predictors of instrumental activities of daily living (IADL) disability. Knowing the optimum cut points of these tests for discriminating people with and without IADL disability could help clinicians or researchers to better interpret the test results and make medical decisions. The purpose of this study was to determine the cutoff values of grip strength and UGS for best discriminating community-dwelling older adults with and without IADL disability, separately for men and women, and to investigate their association with IADL disability. We conducted secondary data analysis on a national dataset collected in the Sarcopenia and Translational Aging Research in Taiwan (START). The data used in this study consisted of health data of 2420 community-dwelling older adults 65 years and older with no history of stroke and with complete data. IADL disability was defined as at least 1 IADL item scored as "need help" or "unable to perform." Receiver operating characteristics analysis was used to estimate the optimum grip strength and UGS cut points for best discriminating older adults with/without IADL disability. The association between each physical performance (grip strength and UGS) and IADL disability was assessed with odds ratios (ORs). With IADL disability as the criterion, the optimal cutoff values of grip strength were 28.7 kg for men and 16.0 kg for women, and those for UGS were 0.76 m/s for men and 0.66 m/s for women. The grip strength test showed satisfactory discriminant validity (area under the curve > 0.7) in men and a strong association with IADL disability (OR > 4). Our cut points using IADL disability as the criterion were close to those indicating frailty or sarcopenia. Our reported cutoffs can serve as criterion-referenced values, along with those previously determined using different indicators, and provide important landmarks on the performance continua of older adults' grip strength and UGS. These landmarks could be useful in interpreting test results, monitoring changes in performance, and identifying individuals requiring timely intervention. For identifying older adults at risk of IADL disability, grip strength is superior to UGS.

  16. Kinetic mechanism of V-shaped twinning in 3C/4H-SiC heteroepitaxy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xin, Bin; Zhang, Yu-Ming; Jia, Ren-Xu, E-mail: rxjia@mail.xidian.edu.cn

    The authors investigated the kinetic mechanism of V-shaped twinning in 3C/4H-SiC heteroepitaxy. A fourfold V-shaped twinning complex was found, and its interface was measured with high-resolution transmission electron microscopy (HRTEM). Two linear coherent boundaries and a nonlinear incoherent boundary (also called the double-position boundary) were observed. On the basis of the HRTEM results, the authors proposed an adatom migration growth model, in which the activation barrier at the coherent boundary is much lower than that at the incoherent boundary. From a kinetic perspective, adatoms are prone to migrate to the side of the boundary with the lower potential energy ifmore » they have sufficient thermal energy to overcome the activation barrier. In the case of a coherent boundary, the growth rates of the domains either side of the boundary can be balanced through the intermigration of adatoms, leading to a linear boundary. Conversely, it is difficult for adatoms to migrate across an incoherent boundary, which results in asynchronous growth rates and a nonlinear boundary.« less

  17. Predicting hand function in older adults: evaluations of grip strength, arm curl strength, and manual dexterity.

    PubMed

    Liu, Chiung-Ju; Marie, Deana; Fredrick, Aaron; Bertram, Jessica; Utley, Kristen; Fess, Elaine Ewing

    2017-08-01

    Hand function is critical for independence in activities of daily living for older adults. The purpose of this study was to examine how grip strength, arm curl strength, and manual dexterous coordination contributed to time-based versus self-report assessment of hand function in community-dwelling older adults. Adults aged ≥60 years without low vision or neurological disorders were recruited. Purdue Pegboard Test, Jamar hand dynamometer, 30-second arm curl test, Jebsen-Taylor Hand Function Test, and the Late-Life Function and Disability Instrument were administered to assess manual dexterous coordination, grip strength, arm curl strength, time-based hand function, and self-report of hand function, respectively. Eighty-four adults (mean age = 72 years) completed the study. Hierarchical multiple regressions show that older adults with better arm curl strength (β = -.25, p < .01) and manual dexterous coordination (β = -.52, p < .01) performed better on the time-based hand function test. In comparison, older adults with better grip strength (β = .40, p < .01), arm curl strength (β = .23, p < .05), and manual dexterous coordination (β = .23, p < .05) were associated with better self-report of upper extremity function. The relationship between grip strength and hand function may be test-specific. Grip strength becomes a significant factor when the test requires grip strength to successfully complete the test tasks. Arm curl strength independently contributed to hand function in both time-based and self-report assessments, indicating that strength of extrinsic muscles of the hand are essential for hand function.

  18. Anticipatory scaling of grip forces when lifting objects of everyday life.

    PubMed

    Hermsdörfer, Joachim; Li, Yong; Randerath, Jennifer; Goldenberg, Georg; Eidenmüller, Sandra

    2011-07-01

    The ability to predict and anticipate the mechanical demands of the environment promotes smooth and skillful motor actions. Thus, the finger forces produced to grasp and lift an object are scaled to the physical properties such as weight. While grip force scaling is well established for neutral objects, only few studies analyzed objects known from daily routine and none studied grip forces. In the present study, eleven healthy subjects each lifted twelve objects of everyday life that encompassed a wide range of weights. The finger pads were covered with force sensors that enabled the measurement of grip force. A scale registered load forces. In a control experiment, the objects were wrapped into paper to prevent recognition by the subjects. Data from the first lift of each object confirmed that object weight was anticipated by adequately scaled forces. The maximum grip force rate during the force increase phase emerged as the most reliable measure to verify that weight was actually predicted and to characterize the precision of this prediction, while other force measures were scaled to object weight also when object identity was not known. Variability and linearity of the grip force-weight relationship improved for time points reached after liftoff, suggesting that sensory information refined the force adjustment. The same mechanism seemed to be involved with unrecognizable objects, though a lower precision was reached. Repeated lifting of the same object within a second and third presentation block did not improve the precision of the grip force scaling. Either practice was too variable or the motor system does not prioritize the optimization of the internal representation when objects are highly familiar.

  19. The Effect of Two Different Hand Exercises on Grip Strength, Forearm Circumference, and Vascular Maturation in Patients Who Underwent Arteriovenous Fistula Surgery

    PubMed Central

    Kong, Sangwon; Lee, Kyung Soo; Kim, Junho

    2014-01-01

    Objective To compare the effect of two different hand exercises on hand strength and vascular maturation in patients who underwent arteriovenous fistula surgery. Methods We recruited 18 patients who had chronic kidney disease and had undergone arteriovenous fistula surgery for hemodialysis. After the surgery, 10 subjects performed hand-squeezing exercise with GD Grip, and other 8 subjects used Soft Ball. The subjects continued the exercises for 4 weeks. The hand grip strength, pinch strength (tip, palmar and lateral pinch), and forearm circumference of the subjects were assessed before and after the hand-squeezing exercise. The cephalic vein size, blood flow velocity and volume were also measured by ultrasonography in the operated limb. Results All of the 3 types of pinch strengths, grip strength, and forearm circumference were significantly increased in the group using GD Grip. Cephalic vein size and blood flow volume were also significantly increased. However, blood flow velocity showed no difference after the exercise. The group using Soft Ball showed a significant increase in the tip and lateral pinch strength and forearm circumference. The cephalic vein size and blood flow volume were also significantly increased. On comparing the effect of the two different hand exercises, hand-squeezing exercise with GD Grip had a significantly better effect on the tip and palmar pinch strength than hand-squeezing exercise with Soft Ball. The effect on cephalic vein size was not significantly different between the two groups. Conclusion The results showed that hand squeezing exercise with GD Grip was more effective in increasing the tip and palmar pinch strength compared to hand squeezing exercise with soft ball. PMID:25379494

  20. Structural insight into GRIP1-PDZ6 in Alzheimer's disease: study from protein expression data to molecular dynamics simulations.

    PubMed

    Chatterjee, Paulami; Roy, Debjani

    2017-08-01

    Protein-protein interaction domain, PDZ, plays a critical role in efficient synaptic transmission in brain. Dysfunction of synaptic transmission is thought to be the underlying basis of many neuropsychiatric and neurodegenerative disorders including Alzheimer's disease (AD). In this study, Glutamate Receptor Interacting Protein1 (GRIP1) was identified as one of the most important differentially expressed, topologically significant proteins in the protein-protein interaction network. To date, very few studies have analyzed the detailed structural basis of PDZ-mediated protein interaction of GRIP1. In order to gain better understanding of structural and dynamic basis of these interactions, we employed molecular dynamics (MD) simulations of GRIP1-PDZ6 dimer bound with Liprin-alpha and GRIP1-PDZ6 dimer alone each with 100 ns simulations. The analyses of MD simulations of Liprin-alpha bound GRIP1-PDZ6 dimer show considerable conformational differences than that of peptide-free dimer in terms of SASA, hydrogen bonding patterns, and along principal component 1 (PC1). Our study also furnishes insight into the structural attunement of the PDZ6 domains of Liprin-alpha bound GRIP1 that is attributed by significant shift of the Liprin-alpha recognition helix in the simulated peptide-bound dimer compared to the crystal structure and simulated peptide-free dimer. It is evident that PDZ6 domains of peptide-bound dimer show differential movements along PC1 than that of peptide-free dimers. Thus, Liprin-alpha also serves an important role in conferring conformational changes along the dimeric interface of the peptide-bound dimer. Results reported here provide information that may lead to novel therapeutic approaches in AD.

  1. Oxygenator Safety Evaluation: A Focus on Connection Grip Strength and Arterial Temperature Measurement Accuracy

    PubMed Central

    Newland, Richard F.; Baker, Robert A.; Sanderson, Andrew J.; Tuble, Sigrid C.; Tully, Phil J.

    2012-01-01

    Abstract: This report describes the assessment of three specific safety-related specifications in the consideration of an alternate oxygenator; first the grip strength relationship between various oxygenator connectors and SMARxT® tubing, second, the grip strength of various biopassive tubings and an isolated SMARxT® connector, and finally, the accuracy of the arterial outlet temperature measurement. Grip strength experiments for the connections between the SMARxT® tubing and the venous reservoir outlet and the oxygenator venous inlet and oxygenator arterial outlet of the Medtronic Affinity®, Sorin Synthesis®, Sorin Primox®, and Terumo Capiox® RX25 oxygenators were performed. In addition we compared the grip strength of polyvinyl chloride, Physio®, Trillium®, Carmeda®, X-Coating®, and SMARxT® tubing. The accuracy of the integrated arterial outlet temperature probes was determined by comparing the temperatures measured by the integrated probe with a precision reference thermometer. Connector grip strength comparisons for the evaluation oxygenators with SMARxT® tubing showed significant variation between oxygenators and connections (p = .02). Evaluation of the arterial outlet showed significant variation between evaluation oxygenators, while at the venous reservoir outlet and oxygenator inlet, there were no significant differences. Grip strength comparison data for the various tubing types demonstrated a main effect for tubing type F(5, 18) = 8.01, p = .002, ηp2 = .77. Temperature accuracy measurements demonstrated that all oxygenators overread the arterial outlet temperature at 15°C, whilst at temperatures ≥25°C, all oxygenators underread the arterial outlet temperature. The integrity of SMARxT® tubing connection is influenced by the connector type, and may decline over time, highlighting the importance to not consider interchanging components of the bypass circuit as inconsequential. PMID:22893983

  2. Normative static grip strength of population of Turkey, effects of various factors and a comparison with international norms.

    PubMed

    Ekşioğlu, Mahmut

    2016-01-01

    Normative data are of importance in ergonomics and clinical settings. Applying normative data internationally is questionable. To this end, this study aimed to establish gender- and age-specific reference values for static (isometric) hand grip strength of normal population of Turkey with special regard to occupational demand, and compare them with the international norms. The secondary aims were to investigate the effects of gender, age-group, weight-group, job-group, hand and several anthropometric variables on static grip strength. A sample of 211 (128 male and 83 female) volunteers aged between 18 and 69 with various occupations participated in the study. Grip strength data were collected using a Jamar dynamometer with standard testing position, protocol and instructions. The mean and std deviation of maximum voluntary static grip strength values (in N) for dominant and non-dominant hands respectively were 455.2 ± 73.6 and 441.5 ± 72.6 for males, and 258 ± 46.1 and 246.2 ± 49.1 for females. The mean female strength was about 57% of the mean male strength value for both dominant and non-dominant hands. There was a curvilinear relationship of grip strength to age, significant differences between genders, hands, and some age-groups, and a correlation to height, body-mass, BMI and hand dimensions depending on the gender. The comparisons with the norms of other world populations indicate that there are cross-national grip strength variations among some nations but not all. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. [Evaluation of grip strength in normal and obese Wistar rats submitted to swimming with overload after median nerve compression].

    PubMed

    Coradinia, Josinéia Gresele; Kakihata, Camila Mayumi Martin; Kunz, Regina Inês; Errero, Tatiane Kamada; Bonfleur, Maria Lúcia; Bertolini, Gladson Ricardo Flor

    2015-01-01

    To verify the functionality through muscle grip strength in animals with obesity induced by monosodium glutamate (MSG) and in control animals, which suffered compression of the right median nerve, and treated with swimming with overload. During the first five days of life, neonatal Wistar rats received subcutaneous injections of MSG. The control group received a hypertonic saline solution. Forty-eight rats were divided into six groups: G1 (control); G2 (control + injury); G3 (control + injury + swimming); G4 (obese); G5 (obese + injury); G6 (obese + injury + swimming). The animals in groups G2, G3, G5 and G6 were submitted to compression of the median nerve and G3 and G6 groups were treated, after injury, with swimming exercise with load for three weeks. The swimming exercise had a progressive duration, according to the week, of 20, 30 and 40minutes. Muscle strength was assessed using a grip strength meter preoperatively and on the 3rd, 7th, 14th and 21st days after surgery. The results were expressed and analyzed using descriptive and inferential statistics. When the grip strength was compared among assessments regardless of group, in the second assessment the animals exhibited lower grip strength. G1 and G4 groups had greater grip strength, compared to G2, G3, G4 and G6. The swimming exercise with overload has not been effective in promoting improvement in muscle grip strength after compression injury of the right median nerve in control and in obese-MSG rats. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.

  4. Using grasping tasks to evaluate hand force coordination in children with hemiplegic cerebral palsy.

    PubMed

    Mackenzie, Samuel J; Getchell, Nancy; Modlesky, Christopher M; Miller, Freeman; Jaric, Slobodan

    2009-08-01

    Mackenzie SJ, Getchell N, Modlesky CM, Miller F, Jaric S. Using grasping tasks to evaluate hand force coordination in children with hemiplegic cerebral palsy. To assess force coordination in children with hemiplegic cerebral palsy (CP) using a device that allows for testing both unimanual and bimanual manipulation tasks performed under static and dynamic conditions. Nonequivalent groups design. University research laboratory for motor control. Six children with hemiplegic CP (age, mean +/- SD, 11.6+/-1.8 y) and 6 typically developing controls (11.6+/-1.6 y). Not applicable. Children performed simple lifting and force-matching static ramp tasks by way of both unimanual and bimanual pulling using a device that measures grip force (force acting perpendicularly at the digits-device contact area) and load force (tangential force). Main outcome measures were grip/load force ratios (grip force scaling) and correlation coefficients (force coupling). CP subjects showed significantly higher grip/load force ratios (P<.05) and slightly lower correlation coefficients than the control group, with more pronounced differences for most tasks when using their involved hand. For subjects with CP, switching from unimanual to bimanual conditions did not bring changes in scaling or coupling for the involved hand (P>.05). Compared with healthy children, the impaired hand function in the hemiplegic CP pediatric population could be reflected in excessive grip force that is also decoupled from ongoing changes in load force. Therefore, the bimanual grip load device used in this study could provide a sensitive measure of grip force coordination in CP, although nonmotor deficits should be taken into account when asking children to perform more complex tasks.

  5. Fast-adapting mechanoreceptors are important for force control in precision grip but not for sensorimotor memory.

    PubMed

    Park, Susanna B; Davare, Marco; Falla, Marika; Kennedy, William R; Selim, Mona M; Wendelschafer-Crabb, Gwen; Koltzenburg, Martin

    2016-06-01

    Sensory feedback from cutaneous mechanoreceptors in the fingertips is important in effective object manipulation, allowing appropriate scaling of grip and load forces during precision grip. However, the role of mechanoreceptor subtypes in these tasks remains incompletely understood. To address this issue, psychophysical tasks that may specifically assess function of type I fast-adapting (FAI) and slowly adapting (SAI) mechanoreceptors were used with object manipulation experiments to examine the regulation of grip force control in an experimental model of graded reduction in tactile sensitivity (healthy volunteers wearing 2 layers of latex gloves). With gloves, tactile sensitivity decreased significantly from 1.9 ± 0.4 to 12.3 ± 2.2 μm in the Bumps task assessing function of FAI afferents but not in a grating orientation task assessing SAI afferents (1.6 ± 0.1 to 1.8 ± 0.2 mm). Six axis force/torque sensors measured peak grip (PGF) and load (PLF) forces generated by the fingertips during a grip-lift task. With gloves there was a significant increase of PGF (14 ± 6%), PLF (17 ± 5%), and grip and load force rates (26 ± 8%, 20 ± 8%). A variable-weight series task was used to examine sensorimotor memory. There was a 20% increase in PGF when the lift of a light object was preceded by a heavy relative to a light object. This relationship was not significantly altered when lifting with gloves, suggesting that the addition of gloves did not change sensorimotor memory effects. We conclude that FAI fibers may be important for the online force scaling but not for the buildup of a sensorimotor memory. Copyright © 2016 the American Physiological Society.

  6. Getting a grip: different actions and visual guidance of the thumb and finger in precision grasping.

    PubMed

    Melmoth, Dean R; Grant, Simon

    2012-10-01

    We manipulated the visual information available for grasping to examine what is visually guided when subjects get a precision grip on a common class of object (upright cylinders). In Experiment 1, objects (2 sizes) were placed at different eccentricities to vary the relative proximity to the participant's (n = 6) body of their thumb and finger contact positions in the final grip orientations, with vision available throughout or only for movement programming. Thumb trajectories were straighter and less variable than finger paths, and the thumb normally made initial contact with the objects at a relatively invariant landing site, but consistent thumb first-contacts were disrupted without visual guidance. Finger deviations were more affected by the object's properties and increased when vision was unavailable after movement onset. In Experiment 2, participants (n = 12) grasped 'glow-in-the-dark' objects wearing different luminous gloves in which the whole hand was visible or the thumb or the index finger was selectively occluded. Grip closure times were prolonged and thumb first-contacts disrupted when subjects could not see their thumb, whereas occluding the finger resulted in wider grips at contact because this digit remained distant from the object. Results were together consistent with visual feedback guiding the thumb in the period just prior to contacting the object, with the finger more involved in opening the grip and avoiding collision with the opposite contact surface. As people can overtly fixate only one object contact point at a time, we suggest that selecting one digit for online guidance represents an optimal strategy for initial grip placement. Other grasping tasks, in which the finger appears to be used for this purpose, are discussed.

  7. Flexible Electrostatic Technology for Capture and Handling Project

    NASA Technical Reports Server (NTRS)

    Keys, Andrew; Bryan, Tom; Horwitz, Chris; Rakoczy, John; Waggoner, Jason

    2015-01-01

    To NASA unfunded & planned missions: This new capability to sense proximity, flexibly align to, and attractively grip and capture practically any object in space without any pre-designed physical features or added sensors or actuators will enable or enhance many of MSFC's strategic emphasis areas in space transportation, and space systems such as: 1. A Flexible Electrostatic gripper can enable the capture, gripping and releasing of an extraterrestrial sample of different minerals or a sample canister (metallic or composite) without requiring a handle or grapple fixture.(B) 2. Flexible self-aligning in-space capture/soft docking or berthing of ISS resupply vehicles, pressurized modules, or nodes for in-space assembly and shielding, radiator, and solar Array deployment for space habitats (C) 3. The flexible electrostatic gripper when combined with a simple steerable extendible boom can grip, position, and release objects of various shapes and materials with low mass and power without any prior handles or physical accommodations or surface contamination for ISS experiment experiments and in-situ repair.(F)(G) 4. The Dexterous Docking concept previously proposed to allow simple commercial resupply ships to station-keep and capture either ISS or an Exploration vehicle for supply or fluid transfer lacked a self-sensing, compliant, soft capture gripper like FETCH that could retract and attach to a CBM. (I) 5. To enable a soft capture and de-orbit of a piece of orbital debris will require self-aligning gripping and holding an object wherever possible (thermal coverings or shields of various materials, radiators, solar arrays, antenna dishes) with little or no residual power while adding either drag or active low level thrust.(K) 6. With the scalability of the FETCH technology, small satellites can be captured and handled or can incorporate FETCH gripper to dock to and handle other small vehicles and larger objects for de-orbiting or mitigating Orbital debris (L) 7. Many of previous MSFC and NASA proposals or concepts can now be realized or simplified by the development of the this initial and future FETCH grippers including commercial resupply, Exploration vehicle assembly, Satellite servicing, and orbital debris removal since a major part of these missions is to align to and capture some handle. Completed Project (2013 - 2014) Flexible Electrostatic Technology for Capture & Handling Project Center Innovation Fund: MSFC CIF Program | Space Technology Mission Directorate (STMD) For more information visit techport.nasa.gov Some NASA technology projects are smaller (for example SBIR/STTR, NIAC and Center Innovation Fund), and will have less content than other, larger projects. Newly created projects may not sensors or injection of permanent adhesives. With gripping forces estimated between 0.5 and 2.5 pounds per square inch or 70-300 lb./sq. ft. of surface contact, the FETCH can turn-on and turn-off rapidly and repeatedly to enable sample handling, soft docking, in-space assembly, and precision relocation for accurate anchor adhesion.

  8. Effects of motor imagery and action observation on hand grip strength, electromyographic activity and intramuscular oxygenation in the hand gripping gesture: A randomized controlled trial.

    PubMed

    Losana-Ferrer, Alejandro; Manzanas-López, Sergio; Cuenca-Martínez, Ferran; Paris-Alemany, Alba; La Touche, Roy

    2018-04-01

    The aim of this study was to evaluate the effects of motor imagery and action observation combined with a hand grip strength program on the forearm muscles. Sixty subjects were selected and randomized into three groups: motor imagery (n = 20), action observation (n = 20), or a control group (n = 20). Outcome measures included hand grip strength, electromyographical activity and intramuscular oxygenation. The hand grip strength significantly increased in the motor imagery (p < .001) and action observation (p < .001) groups compared with the control group, although there were no differences between the both groups (p = .30). In the electromyographical activity, intra-group significant differences were found in motor imagery (p = .002) and action observation (p = .003) groups, although there were no differences between the both groups (p = 1.00) Intramuscular oxygenation results did not show any statistically significant differences between any of the study groups (p > .05). Our results suggest that both motor imagery and action observation training, combined with a hand grip strength program, present a significant strength gain and significant change in the strength and electromyographical activity of the forearm muscles, however no change was found in intramuscular oxygenation. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Grip Strength as an Indicator of Health-Related Quality of Life in Old Age-A Pilot Study.

    PubMed

    Musalek, Christina; Kirchengast, Sylvia

    2017-11-24

    Over the last century life expectancy has increased dramatically nearly all over the world. This dramatic absolute and relative increase of the old aged people component of the population has influenced not only population structure but also has dramatic implications for the individuals and public health services. The aim of the present pilot study was to examine the impact of physical well-being assessed by hand grip strength and social factors estimated by social contact frequency on health-related quality of life among 22 men and 41 women ranging in age between 60 and 94 years. Physical well-being was estimated by hand grip strength, data concerning subjective wellbeing and health related quality of life were collected by personal interviews based on the WHOQOL-BREF questionnaires. Number of offspring and intergenerational contacts were not related significantly to health-related quality of life, while social contacts with non-relatives and hand grip strength in contrast had a significant positive impact on health related quality of life among old aged men and women. Physical well-being and in particular muscle strength-estimated by grip strength-may increase health-related quality of life and is therefore an important source for well-being during old age. Grip strength may be used as an indicator of health-related quality of life.

  10. Grip pressure distributions and associated variability in golf: a two-club comparison.

    PubMed

    Langlais, Sean M; Broker, Jeffrey P

    2014-06-01

    Teaching and playing professionals offer multiple theories concerning the manner in which forces should be applied to the handle of the club during the golf swing. This study extends recent research concerning grip pressures and forces in golf, with the purpose of exploring the similarities and differences between force profiles for a 7-iron and driver swung by proficient golfers. A secondary purpose was to further analyze the way that golfers use grip forces to manipulate the club. Grip forces were measured on eight low handicap golfers (USGA indexes 0 to 7) swinging their own 7-irons and drivers. In total, lead-hand and trail-hand grip forces were isolated as well as anatomically specific forces within the hands. Force profile variability across multiple swings for each golfer and between golfers characterized consistencies and important differences. Correlations between 7-iron and driver force profiles characterized force 'signatures.' The data highlight large fluctuations in grip forces during the swing. Marked differences between participants were observed, involving force magnitudes and phasing. Dominant forces arose primarily from the lead hand, specifically the last three fingers. Force profiles were highly repeatable across swings for a golfer (standard deviations < 7% of total force) and force profile correlations between 7-iron and driver for a golfer were remarkably high (r2 = 0.86). Notably, within swing force variability was greatest during club acceleration, but dramatically decreased at impact.

  11. Action Priority: Early Neurophysiological Interaction of Conceptual and Motor Representations

    PubMed Central

    Koester, Dirk; Schack, Thomas

    2016-01-01

    Handling our everyday life, we often react manually to verbal requests or instruction, but the functional interrelations of motor control and language are not fully understood yet, especially their neurophysiological basis. Here, we investigated whether specific motor representations for grip types interact neurophysiologically with conceptual information, that is, when reading nouns. Participants performed lexical decisions and, for words, executed a grasp-and-lift task on objects of different sizes involving precision or power grips while the electroencephalogram was recorded. Nouns could denote objects that require either a precision or a power grip and could, thus, be (in)congruent with the performed grasp. In a control block, participants pointed at the objects instead of grasping them. The main result revealed an event-related potential (ERP) interaction of grip type and conceptual information which was not present for pointing. Incongruent compared to congruent conditions elicited an increased positivity (100–200 ms after noun onset). Grip type effects were obtained in response-locked analyses of the grasping ERPs (100–300 ms at left anterior electrodes). These findings attest that grip type and conceptual information are functionally related when planning a grasping action but such an interaction could not be detected for pointing. Generally, the results suggest that control of behaviour can be modulated by task demands; conceptual noun information (i.e., associated action knowledge) may gain processing priority if the task requires a complex motor response. PMID:27973539

  12. GRIP Collaboration Portal: Information Management for a Hurricane Field Campaign

    NASA Astrophysics Data System (ADS)

    Conover, H.; Kulkarni, A.; Garrett, M.; Smith, T.; Goodman, H. M.

    2010-12-01

    NASA’s Genesis and Rapid Intensification Processes (GRIP) experiment, carried out in August and September of 2010, was a complex operation, involving three aircraft and their crews based at different airports, a dozen instrument teams, mission scientists, weather forecasters, project coordinators and a variety of other participants. In addition, GRIP was coordinated with concurrent airborne missions: NOAA’s IFEX and then NSF-funded PREDICT. The GRIP Collaboration Portal was developed to facilitate communication within and between the different teams and serve as an information repository for the field campaign, providing a single access point for project documents, plans, weather forecasts, flight reports and quicklook data. The portal was developed using the Drupal open source content management framework. This presentation will cover both technology and participation issues. Specific examples include: Drupal’s large and diverse open source developer community is an advantage in that we were able to reuse many modules rather than develop capabilities from scratch, but integrating multiple modules developed by many people adds to the overall complexity of the site. Many of the communication capabilities provided by the site, such as discussion forums and blogs, were not used. Participants were diligent about posting necessary documents, but the favored communication method remained email. Drupal's developer-friendly nature allowed for quick development of the customized functionality needed to accommodate the rapidly changing requirements of GRIP experiment. DC-8 Overflight of Hurricane Earl during GRIP Mission

  13. Early reduction in toe flexor strength is associated with physical activity in elderly men

    PubMed Central

    Suwa, Masataka; Imoto, Takayuki; Kida, Akira; Yokochi, Takashi

    2016-01-01

    [Purpose] To compare the toe flexor, hand grip and knee extensor strengths of young and elderly men, and to examine the association between toe flexor strength and physical activity or inactivity levels. [Subjects and Methods] Young (n=155, 18–23 years) and elderly (n=60, 65–88 years) men participated in this study. Toe flexor, hand grip, and knee extensor strength were measured. Physical activity (time spent standing/walking per day) and inactivity (time spent sitting per day) were assessed using a self-administered questionnaire. [Results] Toe flexor, hand grip, and knee extensor strength of the elderly men were significantly lower than those of the young men. Standing/walking and sitting times of the elderly men were lower than those of the young men. Toe flexor strength correlated with hand grip and knee extensor strength in both groups. In elderly men, toe flexor strength correlated with standing/walking time. In comparison to the young men’s mean values, toe flexor strength was significantly lower than knee extensor and hand grip strength in the elderly group. [Conclusion] The results suggest that age-related reduction in toe flexor strength is greater than those of hand grip and knee extensor strengths. An early loss of toe flexor strength is likely associated with reduced physical activity in elderly men. PMID:27313353

  14. HEAVY MANUAL WORK THROUGHOUT THE WORKING LIFETIME AND MUSCLE STRENGTH AMONG MEN AT RETIREMENT AGE

    PubMed Central

    Walker-Bone, K; D’Angelo, S; Syddall, HE; Palmer, KT; Cooper, C; Coggon, D; Sayer, AA

    2016-01-01

    Introduction Reductions in heavy manual work as a consequence of mechanisation might impact adversely on muscle strength at older ages. We investigated the association between grip strength at retirement age and lifetime occupational exposure to physically demanding activities. Grip strength is an important predictor of long-term health and physical function in older people. Methods Grip strength (maximum of three readings in each hand) was measured in men from the Hertfordshire Cohort Study at a single examination when their mean age was 65.8 (SD 2.9) years. Associations with lifetime occupational exposure (ascertained by questionnaire) to three activities (standing/walking ≥4 hours/day; lifting ≥25 kg; and energetic work sufficient to induce sweating) were assessed by multivariable linear regression with adjustment for various potential confounders. Results Complete data were available from 1,418 men who had worked for at least 20 years. After adjustment for age, height and weight, those with longer exposures to walking/standing and heavy lifting had lower grip strength, but the relationship disappeared after further adjustment for confounders. Working at physical intensity sufficient to induce sweating was not significantly associated with grip strength. Conclusions We found no evidence that physically demanding occupational activities increase hand grip strength at normal retirement age. Any advantages of regular physical occupational activity may have been obscured by unmeasured socio-economic confounders. PMID:26896253

  15. The bilateral movement condition facilitates maximal but not submaximal paretic-limb grip force in people with post-stroke hemiparesis

    PubMed Central

    DeJong, Stacey L.; Lang, Catherine E.

    2012-01-01

    Objectives Although healthy individuals have less force production capacity during bilateral muscle contractions compared to unilateral efforts, emerging evidence suggests that certain aspects of paretic upper limb task performance after stroke may be enhanced by moving bilaterally instead of unilaterally. We investigated whether the bilateral movement condition affects grip force differently on the paretic side of people with post-stroke hemiparesis, compared to their non-paretic side and both sides of healthy young adults. Methods Within a single session, we compared: 1) maximal grip force during unilateral vs. bilateral contractions on each side, and 2) force contributed by each side during a 30% submaximal bilateral contraction. Results Healthy controls produced less grip force in the bilateral condition, regardless of side (- 2.4% difference), and similar findings were observed on the non-paretic side of people with hemiparesis (- 4.5% difference). On the paretic side, however, maximal grip force was increased by the bilateral condition in most participants (+11.3% difference, on average). During submaximal bilateral contractions in each group, the two sides each contributed the same percentage of unilateral maximal force. Conclusions The bilateral condition facilitates paretic limb grip force at maximal, but not submaximal levels. Significance In some people with post-stroke hemiparesis, the paretic limb may benefit from bilateral training with high force requirements. PMID:22248812

  16. Comparing two methods to record maximal voluntary contractions and different electrode positions in recordings of forearm extensor muscle activity: Refining risk assessments for work-related wrist disorders.

    PubMed

    Dahlqvist, Camilla; Nordander, Catarina; Granqvist, Lothy; Forsman, Mikael; Hansson, Gert-Åke

    2018-01-01

    Wrist disorders are common in force demanding industrial repetitive work. Visual assessment of force demands have a low reliability, instead surface electromyography (EMG) may be used as part of a risk assessment for work-related wrist disorders. For normalization of EMG recordings, a power grip (hand grip) is often used as maximal voluntary contraction (MVC) of the forearm extensor muscles. However, the test-retest reproducibility is poor and EMG amplitudes exceeding 100% have occasionally been recorded during work. An alternative MVC is resisted wrist extension, which may be more reliable. To compare hand grip and resisted wrist extension MVCs, in terms of amplitude and reproducibility, and to examine the effect of electrode positioning. Twelve subjects participated. EMG from right forearm extensors, from four electrode pairs, was recorded during MVCs, on three separate occasions. The group mean EMG amplitudes for resisted wrist extension were 1.2-1.7 times greater than those for hand grip. Resisted wrist extension showed better reproducibility than hand grip. The results indicate that the use of resisted wrist extension is a more accurate measurement of maximal effort of wrist extensor contractions than using hand grip and should increase the precision in EMG recordings from forearm extensor muscles, which in turn will increase the quality of risk assessments that are based on these.

  17. Test-retest intra-rater reliability of grip force in patients with stroke.

    PubMed

    Hammer, Ann; Lindmark, Birgitta

    2003-07-01

    Coefficients of repeatability and reproducibility can be guides in differentiating between real changes and measurement error. The aim was to evaluate test-retest intra-rater reliability of a clinical procedure measuring grip force with Grippit in stroke patients, to assess relationship between grip force of the hands and between sustained and peak grip force. Eighteen patients were tested using the Grippit at two occasions one hour apart. Each occasion comprised three consecutive trials per hand. The paretic hand needs to score a 50 N change within and between occasions to exceed the measurement error in 95% of the observations, irrespective of calculation method. Expressed by CV(within) the measurement error was 10%. There was no learning or fatigue effect during measuring. There was a wide variation between subjects but the mean ratio between sides was 0.66. The mean ratio between sustained and peak grip force was 0.80-0.84. The measurement errors were acceptable and the instrument can be recommended for the use in stroke patients at a department of rehabilitation medicine.

  18. Impact of a daily 10-minute strength and flexibility program in a manufacturing plant.

    PubMed

    Pronk, S J; Pronk, N P; Sisco, A; Ingalls, D S; Ochoa, C

    1995-01-01

    In summary, employees' flexibility and mood showed modest improvements following the implementation of a plant-wide, 10-minute, daily flexibility and strength program. The initial six-week pilot study, administered prior to the plant-wide program implementation, successfully assessed program feasibility, assessed the efficiency of program implementation, identified administrative and logistical concerns, and generated pilot data needed to secure managerial support. Despite the noted significant increases in grip strength in the pilot study, no increases were observed following the six months of plant-wide implementation. This may be related to the differences in low average pretest grip strength for the pilot study compared to the higher scores for the main study population. The pilot study subjects may have received a sufficient exercise stimulus to increase grip strength over the course of six weeks. In contrast, this may not have been the case for the main study subjects due to their higher initial mean grip strength. An increased number of exercises designed to directly impact grip strength may be needed to improve this parameter.

  19. Developing Baby Bag Design by Using Kansei Engineering Method

    NASA Astrophysics Data System (ADS)

    Janari, D.; Rakhmawati, A.

    2016-01-01

    Consumer's preferences and market demand are essential factors for product's success. Thus, in achieving its success, a product should have design that could fulfill consumer's expectation. Purpose of this research is accomplishing baby bag product as stipulated by Kansei. The results that represent Kanseiwords are; neat, unique, comfortable, safe, modern, gentle, elegant, antique, attractive, simple, spacious, creative, colorful, durable, stylish, smooth and strong. Identification value on significance of correlation for durable attribute is 0,000 < 0,005, which means significant to baby's bag. While the value of coefficient regression is 0,812 < 0,005, which means that durable attribute insignificant to baby's bag.The result of the baby's bag final design selectionbased on the questionnaire 3 is resulting the combination of all design. Space for clothes, diaper's space, shoulder grip, side grip, bottle's heater pocket and bottle's pocket are derived from design 1. Top grip, space for clothes, shoulder grip, and side grip are derived from design 2.Others design that were taken are, spaces for clothes from design 3, diaper's space and clothes’ space from design 4.

  20. Force Myography to Control Robotic Upper Extremity Prostheses: A Feasibility Study

    PubMed Central

    Cho, Erina; Chen, Richard; Merhi, Lukas-Karim; Xiao, Zhen; Pousett, Brittany; Menon, Carlo

    2016-01-01

    Advancement in assistive technology has led to the commercial availability of multi-dexterous robotic prostheses for the upper extremity. The relatively low performance of the currently used techniques to detect the intention of the user to control such advanced robotic prostheses, however, limits their use. This article explores the use of force myography (FMG) as a potential alternative to the well-established surface electromyography. Specifically, the use of FMG to control different grips of a commercially available robotic hand, Bebionic3, is investigated. Four male transradially amputated subjects participated in the study, and a protocol was developed to assess the prediction accuracy of 11 grips. Different combinations of grips were examined, ranging from 6 up to 11 grips. The results indicate that it is possible to classify six primary grips important in activities of daily living using FMG with an accuracy of above 70% in the residual limb. Additional strategies to increase classification accuracy, such as using the available modes on the Bebionic3, allowed results to improve up to 88.83 and 89.00% for opposed thumb and non-opposed thumb modes, respectively. PMID:27014682

  1. Spacecraft Observations and Analytic Theory of Crescent-Shaped Electron Distributions in Asymmetric Magnetic Reconnection

    NASA Astrophysics Data System (ADS)

    Egedal, J.; Le, A.; Daughton, W.; Wetherton, B.; Cassak, P. A.; Chen, L.-J.; Lavraud, B.; Torbert, R. B.; Dorelli, J.; Gershman, D. J.; Avanov, L. A.

    2016-10-01

    Supported by a kinetic simulation, we derive an exclusion energy parameter EX providing a lower kinetic energy bound for an electron to cross from one inflow region to the other during magnetic reconnection. As by a Maxwell demon, only high-energy electrons are permitted to cross the inner reconnection region, setting the electron distribution function observed along the low-density side separatrix during asymmetric reconnection. The analytic model accounts for the two distinct flavors of crescent-shaped electron distributions observed by spacecraft in a thin boundary layer along the low-density separatrix.

  2. Spacecraft Observations and Analytic Theory of Crescent-Shaped Electron Distributions in Asymmetric Magnetic Reconnection

    NASA Technical Reports Server (NTRS)

    Egedal, J.; Le, A.; Daughton, W.; Wetherton, B.; Cassak, P.A.; Chen, L.-J.; Lavraud, B.; Trobert, Roy; Dorelli, J.; Gershman, D. J.; hide

    2016-01-01

    Supported by a kinetic simulation, we derive an exclusion energy parameter EX providing a lower kinetic energy bound for an electron to cross from one inflow region to the other during magnetic reconnection. As by a Maxwell Demon, only high energy electrons are permitted to cross the inner-reconnection region, setting the electron distribution function observed along the low density side separatrix during asymmetric reconnection. The analytic model accounts for the two distinct flavors of crescent-shaped electron distributions observed by spacecraft in a thin boundary layer along the low density separatrix.

  3. Effect of annealing ambient on anisotropic retraction of film edges during solid-state dewetting of thin single crystal films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Gye Hyun; Thompson, Carl V., E-mail: cthomp@mit.edu; Ma, Wen

    During solid-state dewetting of thin single crystal films, film edges retract at a rate that is strongly dependent on their crystallographic orientations. Edges with kinetically stable in-plane orientations remain straight as they retract, while those with other in-plane orientations develop in-plane facets as they retract. Kinetically stable edges have retraction rates that are lower than edges with other orientations and thus determine the shape of the natural holes that form during solid-state dewetting. In this paper, measurements of the retraction rates of kinetically stable edges for single crystal (110) and (100) Ni films on MgO are presented. Relative retraction ratesmore » of kinetically stable edges with different crystallographic orientations are observed to change under different annealing conditions, and this accordingly changes the initial shapes of growing holes. The surfaces of (110) and (100) films were also characterized using low energy electron diffraction, and different surface reconstructions were observed under different ambient conditions. The observed surface structures were found to correlate with the observed changes in the relative retraction rates of the kinetically stable edges.« less

  4. Further Results on the Disturbance Response of a Double Integrator Controlled by Saturating Linear Static State Feedback

    DTIC Science & Technology

    2011-07-13

    Anton A. Stoorvogel b, Håvard Fjær Grip a aSchool of Electrical Engineering and Computer Science, Washington State University, Pullman, WA 99164-2752...utwente.nl ( Anton A. Stoorvogel), grip@ieee.org (Håvard Fjær Grip). of a double integrator controlled by a saturating linear static state feedback...References Chitour, Y., 2001. On the Lp stabilization of the double integrator subject to input saturation. ESAIM: Control, Optimization and Calculus

  5. GRIP Experiment 2010

    NASA Image and Video Library

    2010-08-14

    Jeffrey Beyon, left, and Paul Joseph Petzar, right, from NASA's Langley Research Center, work with DAWN Air Data Acquisition and Processing software aboard NASA's DC-8 research aircraft, Sunday, Aug. 15, 2010, in support of the GRIP experiment at Fort Lauderdale International Airport in Fort Lauderdale, Fla. The Genesis and Rapid Intensification Processes (GRIP) experiment is a NASA Earth science field experiment in 2010 that is being conducted to better understand how tropical storms form and develop into major hurricanes. Photo Credit: (NASA/Paul E. Alers)

  6. The influence of hand positions on biomechanical injury risk factors at the wrist joint during the round-off skills in female gymnastics.

    PubMed

    Farana, Roman; Jandacka, Daniel; Uchytil, Jaroslav; Zahradnik, David; Irwin, Gareth

    2017-01-01

    The aim of this study was to examine the biomechanical injury risk factors at the wrist, including joint kinetics, kinematics and stiffness in the first and second contact limb for parallel and T-shape round-off (RO) techniques. Seven international-level female gymnasts performed 10 trials of the RO to back handspring with parallel and T-shape hand positions. Synchronised kinematic (3D motion analysis system; 247 Hz) and kinetic (two force plates; 1235 Hz) data were collected for each trial. A two-way repeated measure analysis of variance (ANOVA) assessed differences in the kinematic and kinetic parameters between the techniques for each contact limb. The main findings highlighted that in both the RO techniques, the second contact limb wrist joint is exposed to higher mechanical loads than the first contact limb demonstrated by increased axial compression force and loading rate. In the parallel technique, the second contact limb wrist joint is exposed to higher axial compression load. Differences between wrist joint kinetics highlight that the T-shape technique may potentially lead to reducing these bio-physical loads and consequently protect the second contact limb wrist joint from overload and biological failure. Highlighting the biomechanical risk factors facilitates the process of technique selection making more objective and safe.

  7. [Prevalence of X-ray signs of femoroacetabular impingement in Mexican population].

    PubMed

    Gutiérrez-Ramos, R; Ávalos-Calderón, S A; Bahena-Peniche, L A

    2017-01-01

    Femoroacetabular impingement (FAI) is a suggested diagnosis for pain in the hip in the absence of other apparent causes. It is thought to be a cause of progressive arthrosis of the hip. Our objective was to determine the prevalence of radiographic data of FAI in the adult population without hip pathology over a period of six months. Analytical, observational, multicentric, ambispective and transverse study based on digital X-rays analysis. Measurements of the lateral center-edge angle of Wiberg, acetabular inclination, Tönnis angle and the neck shaft angle of the proximal femur were made; a pistol grip deformity of the femoral head, the triangular index and the shape of the coxofemoral joint were also evaluated. From a total of 212 hips evaluated, 104 were in males and 108 in females, with an average age of 42.81 years; 21 had a pistol grip deformity and a positive triangular index for cam type. The pincer type was found in 12 hips. In this multicentric study, the FAI cam type predominated in men on the right side; the pincer type predominated in women on the left side; this is similar to what has been reported in other populations. This study is limited by the wide variation in the femoral rotation; as an advantage, it was randomly carried out and provides some data on the prevalence of deformities of the hip, not previously registered.

  8. Lunar surface operations. Volume 3: Robotic arm for lunar surface vehicle

    NASA Technical Reports Server (NTRS)

    Shields, William; Feteih, Salah; Hollis, Patrick

    1993-01-01

    A robotic arm for a lunar surface vehicle that can help in handling cargo and equipment, and remove obstacles from the path of the vehicle is defined as a support to NASA's intention to establish a lunar based colony by the year 2010. Its mission would include, but not limited to the following: exploration, lunar sampling, replace and remove equipment, and setup equipment (e.g. microwave repeater stations). Performance objectives for the robotic arm include a reach of 3 m, accuracy of 1 cm, arm mass of 100 kg, and lifting capability of 50 kg. The end effectors must grip various sizes and shapes of cargo; push, pull, turn, lift, or lower various types of equipment; and clear a path on the lunar surface by shoveling, sweeping aside, or gripping the obstacle present in the desired path. The arm can safely complete a task within a reasonable amount of time; the actual time is dependent upon the task to be performed. The positioning of the arm includes a manual backup system such that the arm can be safely stored in case of failure. Remote viewing and proximity and positioning sensors are incorporated in the design of the arm. The following specific topic are addressed in this report: mission and requirements, system design and integration, mechanical structure, modified wrist, structure-to-end-effector interface, end-effectors, and system controls.

  9. Revolutionizing (robot-assisted) laparoscopic gamma tracing using a drop-in gamma probe technology

    PubMed Central

    van Oosterom, Matthias N; Simon, Hervé; Mengus, Laurent; Welling, Mick M; van der Poel, Henk G; van den Berg, Nynke S; van Leeuwen, Fijs WB

    2016-01-01

    In complex (robot-assisted) laparoscopic radioguided surgery procedures, or when low activity lesions are located nearby a high activity background, the limited maneuverability of a laparoscopic gamma probe (LGP; 4 degrees of freedom (DOF)) may hinder lesion identification. We investigated a drop-in gamma probe (DIGP) technology to be inserted via a trocar, after which the laparoscopic surgical tool at hand can pick it up and maneuver it. Phantom experiments showed that distinguishing a low objective from a high background source (1:100 ratio) was only possible with the detector faced >90° from the high background source. Signal-low-objective-to-background ratios of 3.77, 2.01 and 1.84 were found for detector angles of 90°, 135° and 180°, respectively, whereas detector angles of 0° and 45° were unable to distinguish the sources. This underlines the critical role probe positioning plays. We then focused on engineering of the gripping part for optimal DIGP pick-up with a conventional laparoscopic forceps (4 DOF) or a robotic forceps (6 DOF). DIGPs with 0°, 45°, 90°, and 135° -grip orientations were designed, and their maneuverability- and scanning direction were evaluated and compared to a conventional LGP. The maneuverability- and scanning direction of the DIGP was found highest when using the robotic forceps, with the largest effective scanning direction range obtained with the 90° -grip design (0-180° versus 0-111°, 0-140°, and 37-180° for 0°, 45° and 135° -grip designs, respectively). For the laparoscopic forceps, the scan direction directly translated from the angle of the grip design with the advantage that the 135° -gripped DIGP could be faced backwards (not possible with the conventional LGP). In the ex vivo clinical setup, the surgeon rated DIGP pick-up most convenient for the 45°-grip design. Concluding, the DIGP technology was successfully introduced. Optimization of the grip design and grasping angle of the DIGP increased its utility for (robot-assisted) laparoscopic gamma tracing. PMID:27069762

  10. Aging enhances serum cytokine response but not task-induced grip strength declines in a rat model of work-related musculoskeletal disorders

    PubMed Central

    2011-01-01

    Background We previously reported early tissue injury, increased serum and tissue inflammatory cytokines and decreased grip in young rats performing a moderate demand repetitive task. The tissue cytokine response was transient, the serum response and decreased grip were still evident by 8 weeks. Thus, here, we examined their levels at 12 weeks in young rats. Since aging is known to enhance serum cytokine levels, we also examined aged rats. Methods Aged and young rats, 14 mo and 2.5 mo of age at onset, respectfully, were trained 15 min/day for 4 weeks, and then performed a high repetition, low force (HRLF) reaching and grasping task for 2 hours/day, for 12 weeks. Serum was assayed for 6 cytokines: IL-1alpha, IL-6, IFN-gamma, TNF-alpha, MIP2, IL-10. Grip strength was assayed, since we have previously shown an inverse correlation between grip strength and serum inflammatory cytokines. Results were compared to naïve (grip), and normal, food-restricted and trained-only controls. Results Serum cytokines were higher overall in aged than young rats, with increases in IL-1alpha, IFN-gamma and IL-6 in aged Trained and 12-week HRLF rats, compared to young Trained and HRLF rats (p < 0.05 and p < 0.001, respectively, each). IL-6 was also increased in aged 12-week HRLF versus aged normal controls (p < 0.05). Serum IFN-gamma and MIP2 levels were also increased in young 6-week HRLF rats, but no cytokines were above baseline levels in young 12-week HRLF rats. Grip strength declined in both young and aged 12-week HRLF rats, compared to naïve and normal controls (p < 0.05 each), but these declines correlated only with IL-6 levels in aged rats (r = -0.39). Conclusion Aging enhanced a serum cytokine response in general, a response that was even greater with repetitive task performance. Grip strength was adversely affected by task performance in both age groups, but was apparently influenced by factors other than serum cytokine levels in young rats. PMID:21447183

  11. Muscular activity of different shooting distances, different release techniques, and different performance levels, with and without stabilizers, in target archery.

    PubMed

    Clarys, J P; Cabri, J; Bollens, E; Sleeckx, R; Taeymans, J; Vermeiren, M; Van Reeth, G; Voss, G

    1990-01-01

    The quadruple approach in the title refers to four different studies over a period of 3 years. The common factor in these studies is the methodology of the (Brussels) Electromyographic Signal Processing and Analysis System (ESPAS), a hardware and software EMG data acquisition system that has constantly been improved. Therefore, the ESPAS methodology is described extensively (i.e. the electrodes, amplifier, tape-recorder and processing hardware). Experiment 1 investigated muscular behaviour in target shooting, both indoors (18 and 25 m) and outdoors (50, 70 and 90 m). It was found (via iEMG) that a significant increase in activity only exists between 25 and 50 m, and that there is no linear increase of activity with increased distance. No differences in muscular pattern (IDANCO system: Clarys and Cabri, 1988) or activity between the indoor distances and between the outdoor distances were found. Experiment 2 investigated the muscular economy of four string grips: the three-finger grip, two-finger grip, thumb grip and reversed grip. The largest variations in activity were found for the two most unfamiliar grips, i.e. the thumb and reversed grips; however, low iEMG and the rapid precision improvement (over a limited number of shots) suggest that the thumb grip, if practised long enough, might be the most economical technique. Experiment 3 attempted to differentiate muscular activity and a number of performance variables in three different populations of archers--Olympic athletes, National competitors and beginners--in order to obtain feedback regarding improved performance. Apparently, overall muscle pattern, intensities and arrow speed were not discriminatory. The differences found between the groups (or levels of skill) were affected by the ability to reproduce identical patterns and arrow velocities in consecutive shots and by the constancy of neuromuscular control of the M. trapezius, M. biceps brachii and M. extensor digitorum. Finally, Experiment 4 investigated the muscular activity of elite archers shooting at distances of 70 and 90 m with and without stabilizers. Differences in iEMG were not supported by differences in precision. Over time, the low iEMG in shooting without stabilizers increases precision and delays fatigue.

  12. An investigation of the tri-bar gripping system on isometric muscular endurance.

    PubMed

    Drury, Daniel G; Faggiono, Heath; Stuempfle, Kristin J

    2004-11-01

    Recently, a new product called the Tri-Bar has been introduced as an alternative to the standard round weightlifting bar. The Tri-Bar has the same weight, length, and circumference as a standard weightlifting bar and differs only in that the shape of the bar is formed like a triangle with rounded edges. Theoretically, the shape of the bar will enhance gripping comfort and increase muscular endurance. We studied 32 moderately trained males who were free from upper-body injury or limitation. Each participant completed 4 visits to the lab as part of 2 separate investigations. The first investigation was a comparison of straight-arm hang times while grasping a standard Olympic bar or a Tri-Bar attached to the top of a power rack. The second investigation involved grasping a standard revolving cable handle or a Tri-Bar revolving handle attached to a weight equal to half the subject's body weight. In both investigations, time was used as a measure of isometric muscular endurance. Differences were determined using a dependent t-test, and a level of significance was set at p < 0.05. Mean hang times were significantly longer when the men hung from the Tri-Bar (107.6 seconds) versus the standard bar (95.4 seconds) (p = 0.015). Conversely, in the investigation using the revolving handles, the round bar produced longer grasping times (71.5 seconds) than the Tri-Bar (62.6 seconds) (p = 0.000). The results of this investigation indicate that a fixed and stable Tri-Bar may help to increase hang time, but a Tri-Bar free to rotate within the grasp may decrease grasping time in comparison to a standard round handle. With regard to exercises that require isometric grasping, the Tri-Bar may be an effective alternative to the standard bar for increasing isometric grasping endurance.

  13. The modulation of the motor resonance triggered by reach-to-grasp movements: No role of human physical similarity as conveyed by age.

    PubMed

    Marino, Barbara F M; Ricciardelli, Paola

    2017-07-01

    The activation of the mirror-neuron circuit during the observation of motor acts is thought to be the basis of human capacity to read the intentions behind the behavior of others. Growing empirical evidence shows a different activation of the mirror-neuron resonance mechanism depending on how much the observer and the observed agent share their motor repertoires. Here, the possible modulatory effect of physical similarity between the observer and the agent was investigated in three studies. We used a visuo-motor priming task in which participants were asked to categorize manipulable and non-manipulable objects into natural or man-made kinds after having watched precision and power reach-to-grasp movements. Physical similarity was manipulated by presenting reach-to-grasp movements performed by the hands of actors of three different age ranges that are adults of the same age as the participants, children, and elderly. Faster responses were observed in trials where power grip movements were performed by the adults and precision grip movements were performed by the elderly (Main Study). This finding is not in keeping with the idea that physical similarity shapes the mirror-neuron resonance. Instead, it suggests an effect of the kinematic organization of the reach-to-grasp movements, which systematically changed with the actor age as revealed by a kinematic analysis. The differential effect played by adult and elderly actor primes was lost when static grasping hands (Control Study 1) and reach-to-grasp movements with uniform kinematic profiles (Control Study 2) were used. Therefore, we found preliminary evidence that mirror-neuron resonance is not shaped by physical similarity but by the kinematics of the observed action. This finding is novel as it suggests that human ability to read the intentions behind the behavior of others may benefit from a mere visual processing of spatiotemporal patterns.

  14. Manipulation of a fragile object by elderly individuals.

    PubMed

    Gorniak, Stacey L; Zatsiorsky, Vladimir M; Latash, Mark L

    2011-08-01

    We investigated strategies of healthy elderly participants (74-84 years old) during prehension and transport of an object with varying degrees of fragility. Fragility was specified as the maximal normal force that the object could withstand without collapsing. Specifically, kinetic and kinematic variables as well as and force covariation indices were quantified and compared to those shown by young healthy persons (19-28 years old). We tested three hypotheses related to age-related changes in two safety margins (slip safety margin and crush safety margin) and indices of force covariation. Compared to young controls, elderly individuals exhibited a decrease in object acceleration and an increase in movement time, an increase in grip force production, a decrease in the correlation between grip and load forces, an overall decrease in indices of multi-digit synergies, and lower safety margin indices computed with respect to both dropping and crushing the object. Elderly participants preferred to be at a relatively lower risk of crushing the object even if this led to a higher risk of dropping it. Both groups showed an increase in the index of synergy stabilizing total normal force produced by the four fingers with increased fragility of the object. Age-related changes are viewed as a direct result of physiological changes due to aging, not adaptation to object fragility. Such changes in overall characteristics of prehension likely reflect diminished synergic control by the central nervous system of finger forces with aging. The findings corroborate an earlier hypothesis on an age-related shift from synergic to element-based control.

  15. Status of Middle Atmosphere-Climate Models: Results SPARC-GRIPS

    NASA Technical Reports Server (NTRS)

    Pawson, Steven; Kodera, Kunihiko

    2003-01-01

    The middle atmosphere is an important component of the climate system, primarily because of the radiative forcing of ozone. Middle atmospheric ozone can change, over long times, because of changes in the abundance of anthropogenic pollutants which catalytically destroy it, and because of the temperature sensitivity of kinetic reaction rates. There is thus a complex interaction between ozone, involving chemical and climatic mechanisms. One question of interest is how ozone will change over the next decades , as the "greenhouse-gas cooling" of the middle atmosphere increases but the concentrations of chlorine species decreases (because of policy changes). concerns the climate biases in current middle atmosphere-climate models, especially their ability to simulate the correct seasonal cycle at high latitudes, and the existence of temperature biases in the global mean. A major obstacle when addressing this question This paper will present a summary of recent results from the "GCM-Reality Intercomparison Project for SPARC" (GRIPS) initiative. A set of middle atmosphere-climate models has been compared, identifying common biases. Mechanisms for these biases are being studied in some detail, including off-line assessments of the radiation transfer codes and coordinated studies of the impacts of gravity wave drag due to sub-grid-scale processes. ensemble of models will be presented, along with numerical experiments undertaken with one or more models, designed to investigate the mechanisms at work in the atmosphere. The discussion will focus on dynamical and radiative mechanisms in the current climate, but implications for coupled ozone chemistry and the future climate will be assessed.

  16. Grip strength measurement for frailty assessment in patients with vascular disease and associations with comorbidity, cardiac risk, and sarcopenia.

    PubMed

    Reeve, Thomas E; Ur, Rebecca; Craven, Timothy E; Kaan, James H; Goldman, Matthew P; Edwards, Matthew S; Hurie, Justin B; Velazquez-Ramirez, Gabriela; Corriere, Matthew A

    2018-05-01

    Frailty is associated with adverse events, length of stay, and nonhome discharge after vascular surgery. Frailty measures based on walking-based tests may be impractical or invalid for patients with walking impairment from symptoms or sequelae of vascular disease. We hypothesized that grip strength is associated with frailty, comorbidity, and cardiac risk among patients with vascular disease. Dominant hand grip strength was measured during ambulatory clinic visits among patients with vascular disease (abdominal aortic aneurysm [AAA], carotid stenosis, and peripheral artery disease [PAD]). Frailty prevalence was defined on the basis of the 20th percentile of community-dwelling population estimates adjusted for age, gender, and body mass index. Associations between grip strength, Charlson Comorbidity Index (CCI), Revised Cardiac Risk Index (RCRI), and sarcopenia (based on total psoas area for patients with cross-sectional abdominal imaging) were evaluated using linear and logistic regression. Grip strength was measured in 311 participants; all had sufficient data for CCI calculation, 217 (69.8%) had sufficient data for RCRI, and 88 (28.3%) had cross-sectional imaging permitting psoas measurement. Eighty-six participants (27.7%) were categorized as frail on the basis of grip strength. Frailty was associated with CCI (odds ratio, 1.86; 95% confidence interval, 1.34-2.57; P = .0002) in the multivariable model. Frail participants also had a higher average number of RCRI components vs nonfrail patients (mean ± standard deviation, 1.8 ± 0.8 for frail vs 1.5 ± 0.7 for nonfrail; P = .018); frailty was also associated with RCRI in the adjusted multivariable model (odds ratio, 1.75; 95% confidence interval, 1.16-2.64; P = .008). Total psoas area was lower among patients categorized as frail vs nonfrail on the basis of grip strength (21.0 ± 6.6 vs 25.4 ± 7.4; P = .010). Each 10 cm 2 increase in psoas area was associated with a 5.7 kg increase in grip strength in a multivariable model adjusting for age and gender (P < .0001). Adjusted least squares mean psoas diameter estimates were 25.5 ± 1.1 cm 2 for participants with AAA, 26.7 ± 2.0 cm 2 for participants with carotid stenosis, and 22.7 ± 0.8 cm 2 for participants with PAD (P = .053 for PAD vs AAA; P = .057 for PAD vs carotid stenosis; and P = .564 for AAA vs carotid stenosis). Grip strength is useful for identifying frailty among patients with vascular disease. Frail status based on grip strength is associated with comorbidity, cardiac risk, and sarcopenia in this population. These findings suggest that grip strength may have utility as a simple and inexpensive risk screening tool that is easily implemented in ambulatory clinics, avoids the need for imaging, and overcomes possible limitations of walking-based measures. Lower mean psoas diameters among patients with PAD vs other diagnoses may warrant consideration of specific approaches to morphomic analysis. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  17. Short-Term Effects of Whole-Body Vibration Combined with Task-Related Training on Upper Extremity Function, Spasticity, and Grip Strength in Subjects with Poststroke Hemiplegia: A Pilot Randomized Controlled Trial.

    PubMed

    Lee, Jung-Sun; Kim, Chang-Yong; Kim, Hyeong-Dong

    2016-08-01

    The aim of this study was to determine the effect of whole-body vibration training combined with task-related training on arm function, spasticity, and grip strength in subjects with poststroke hemiplegia. Forty-five subjects with poststroke were randomly allocated to 3 groups, each with 15 subjects as follows: control group, whole-body vibration group, and whole-body vibration plus task-related training group. Outcome was evaluated by clinical evaluation and measurements of the grip strength before and 4 weeks after intervention. Our results show that there was a significantly greater increase in the Fugl-Meyer scale, maximal grip strength of the affected hand, and grip strength normalized to the less affected hand in subjects undergoing the whole-body vibration training compared with the control group after the test. Furthermore, there was a significantly greater increase in the Wolf motor function test and a decrease in the modified Ashworth spasticity total scores in subjects who underwent whole-body vibration plus task-related training compared with those in the other 2 groups after the test. The findings indicate that the use of whole-body vibration training combined with task-related training has more benefits on the improvement of arm function, spasticity, and maximal grip strength than conventional upper limb training alone or with whole-body vibration in people with poststroke hemiplegia.

  18. Does the type of somatosensory information from the contralateral finger touch affect grip force control while lifting an object?

    PubMed

    Chen, Bing; Aruin, Alexander S

    2013-11-27

    The magnitude of grip force used to lift and transport a hand-held object is decreased if a light finger touch from the contralateral arm is provided to the wrist of the target arm. We investigated whether the type of contralateral arm sensory input that became available with the finger touch to the target arm affects the way grip force is reduced. Nine healthy subjects performed the same task of lifting and transporting an instrumented object with no involvement of the contralateral arm and when an index finger touch of the contralateral arm was provided to the wrist, elbow, and shoulder. Touching the wrist and elbow involved movements of the contralateral arm; no movements were produced while touching the shoulder. Grip force was reduced by approximately the same amount in all conditions with the finger touch compared to the no touch condition. This suggests that information from the muscle and joint receptors of the contralateral arm is used in control of grip force when a finger touch is provided to the wrist and elbow, and cutaneous information is utilized when lifting an object while touching the shoulder. The results of the study provide additional evidence to support the use of a second arm in the performance of activities of daily living and stress the importance of future studies investigating contralateral arm sensory input in grip force control. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Associations between aging-related changes in grip strength and cognitive function in older adults: A systematic review.

    PubMed

    Zammit, Andrea R; Robitaille, Annie; Piccinin, Andrea; Muniz-Terrera, Graciela; Hofer, Scott M

    2018-03-08

    Grip strength and cognitive function reflect upper body muscle strength and mental capacities. Cross-sectional research has suggested that in old age these two processes are moderately to highly associated, and that an underlying common cause drives this association. Our aim was to synthesize and evaluate longitudinal research addressing whether changes in grip strength are associated with changes in cognitive function in healthy older adults. We systematically reviewed English-language research investigating the longitudinal association between repeated measures of grip strength and of cognitive function in community-dwelling older adults to evaluate the extent to which the two indices decline concurrently. We used four search engines: Embase, PsychINFO, PubMed, and Web of Science. Of 459 unique citations, 6 met our full criteria: 4 studies reported a longitudinal association between rates of change in grip strength and cognitive function in older adults, 2 of which reported the magnitudes of these associations as ranging from low to moderate; 2 studies reported significant cross-sectional but not longitudinal associations among rates of change. All studies concluded that cognitive function and grip strength declined, on average, with increasing age, although with little to no evidence for longitudinal associations among rates of change. Future research is urged to expand the study of physical and cognitive associations in old age using a within-person and multi-study integrative approach to evaluate the reliability of longitudinal results with greater emphasis on the magnitude of this association.

  20. Physical Activity and Kidney Injury in Pediatric and Young Adult Kidney Transplant Recipients.

    PubMed

    Wolf, Mattie F; George, Roshan P; Warshaw, Barry; Wang, Elizabeth; Greenbaum, Larry A

    2016-12-01

    To quantify physical activity and grip strength in pediatric kidney transplant recipients and describe attitudes about exercise and exercise counseling given concerns about allograft injury. This was a cross-sectional analysis of 101 kidney transplant recipients (7-21 years old) >6 months post-transplant. Patients completed the Physical Activity Questionnaire (PAQ). Grip strength was measured with a dynamometer. We asked about activity limitations and provider counseling. Univariate analysis and multiple linear regression were used to determine independent predictors of PAQ score and grip strength z score. We enrolled 101 of 122 eligible patients. Median PAQ score was 2.2 (range 0-5) and was lower compared with controls (P < .001). The average grip strength z score was -1.1 and -0.7 in the right and left hand, respectively. Predictors of lower grip strength were younger age (P = .036), non-African American race (P = .029), lower height z score (P = .010), and longer percentage of lifetime with kidney disease (P = .029). Although 49% and 67% limited exercise before and after transplant, respectively, 67% reported increased activity after transplant. By parent report, provider counseling included limiting certain activities (71%) and encouraging regular exercise (45%). Physical activity and grip strength are low after kidney transplant. Patients perceive an emphasis on exercise limitations rather than the benefits of regular exercise. Interventions that encourage physical activity may be beneficial. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Associations of work activities requiring pinch or hand grip or exposure to hand-arm vibration with finger and wrist osteoarthritis: a meta-analysis.

    PubMed

    Hammer, Paula E C; Shiri, Rahman; Kryger, Ann I; Kirkeskov, Lilli; Bonde, Jens Peter

    2014-03-01

    We systematically reviewed the epidemiologic evidence linking finger and wrist osteoarthritis (OA) with work activities requiring pinch or hand grip or exposure to hand-arm vibration (HAV). PubMed and Embase databases were searched up to June 2013. We selected studies assessing the associations of radiographic diagnosed finger and/or wrist joint OA with work activities involving pinch or hand grip or exposure to HAV. We used specific criteria to evaluate completeness of reporting, potential confounding, and bias. Pooled odds ratios (OR) were computed using random-effects meta-analyses. Of the 19 studies included, 17 were cross-sectional, 1 was a prospective cohort, and 1 a case-control study. The meta-analyses of studies that controlled their estimates for at least age and gender showed the associations of pinch grip work with proximal interphalangeal joint [OR 1.56, 95% confidence interval (95% CI) 1.09-2.23] and the first carpometacarpal joint OA (OR 2.10, 95% CI 1.06-4.17), but not with distal interphalangeal, metacarpalphalangeal, or wrist joints OA. Hand grip work and exposure to HAV were not associated with any finger or wrist OA. Epidemiological studies provide limited evidence that pinch grip may increase the risk of wrist or finger OA, but causal relation cannot be resolved because of cross-sectional designs and inadequate characterization of biomechanical strain to the hand and wrist.

  2. Functional dissociation between action and perception of object shape in developmental visual object agnosia.

    PubMed

    Freud, Erez; Ganel, Tzvi; Avidan, Galia; Gilaie-Dotan, Sharon

    2016-03-01

    According to the two visual systems model, the cortical visual system is segregated into a ventral pathway mediating object recognition, and a dorsal pathway mediating visuomotor control. In the present study we examined whether the visual control of action could develop normally even when visual perceptual abilities are compromised from early childhood onward. Using his fingers, LG, an individual with a rare developmental visual object agnosia, manually estimated (perceptual condition) the width of blocks that varied in width and length (but not in overall size), or simply picked them up across their width (grasping condition). LG's perceptual sensitivity to target width was profoundly impaired in the manual estimation task compared to matched controls. In contrast, the sensitivity to object shape during grasping, as measured by maximum grip aperture (MGA), the time to reach the MGA, the reaction time and the total movement time were all normal in LG. Further analysis, however, revealed that LG's sensitivity to object shape during grasping emerged at a later time stage during the movement compared to controls. Taken together, these results demonstrate a dissociation between action and perception of object shape, and also point to a distinction between different stages of the grasping movement, namely planning versus online control. Moreover, the present study implies that visuomotor abilities can develop normally even when perceptual abilities developed in a profoundly impaired fashion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Bohr's Electron was Problematic for Einstein: String Theory Solved the Problem

    NASA Astrophysics Data System (ADS)

    Webb, William

    2013-04-01

    Neils Bohr's 1913 model of the hydrogen electron was problematic for Albert Einstein. Bohr's electron rotates with positive kinetic energies +K but has addition negative potential energies - 2K. The total net energy is thus always negative with value - K. Einstein's special relativity requires energies to be positive. There's a Bohr negative energy conflict with Einstein's positive energy requirement. The two men debated the problem. Both would have preferred a different electron model having only positive energies. Bohr and Einstein couldn't find such a model. But Murray Gell-Mann did! In the 1960's, Gell-Mann introduced his loop-shaped string-like electron. Now, analysis with string theory shows that the hydrogen electron is a loop of string-like material with a length equal to the circumference of the circular orbit it occupies. It rotates like a lariat around its centered proton. This loop-shape has no negative potential energies: only positive +K relativistic kinetic energies. Waves induced on loop-shaped electrons propagate their energy at a speed matching the tangential speed of rotation. With matching wave speed and only positive kinetic energies, this loop-shaped electron model is uniquely suited to be governed by the Einstein relativistic equation for total mass-energy. Its calculated photon emissions are all in excellent agreement with experimental data and, of course, in agreement with those -K calculations by Neils Bohr 100 years ago. Problem solved!

  4. Gain-of-function glutamate receptor interacting protein 1 variants alter GluA2 recycling and surface distribution in patients with autism

    PubMed Central

    Mejias, Rebeca; Adamczyk, Abby; Anggono, Victor; Niranjan, Tejasvi; Thomas, Gareth M.; Sharma, Kamal; Skinner, Cindy; Schwartz, Charles E.; Stevenson, Roger E.; Fallin, M. Daniele; Kaufmann, Walter; Pletnikov, Mikhail; Valle, David; Huganir, Richard L.; Wang, Tao

    2011-01-01

    Glutamate receptor interacting protein 1 (GRIP1) is a neuronal scaffolding protein that interacts directly with the C termini of glutamate receptors 2/3 (GluA2/3) via its PDZ domains 4 to 6 (PDZ4–6). We found an association (P < 0.05) of a SNP within the PDZ4-6 genomic region with autism by genotyping autistic patients (n = 480) and matched controls (n = 480). Parallel sequencing identified five rare missense variants within or near PDZ4–6 only in the autism cohort, resulting in a higher cumulative mutation load (P = 0.032). Two variants correlated with a more severe deficit in reciprocal social interaction in affected sibling pairs from proband families. These variants were associated with altered interactions with GluA2/3 and faster recycling and increased surface distribution of GluA2 in neurons, suggesting gain-of-function because GRIP1/2 deficiency showed opposite phenotypes. Grip1/2 knockout mice exhibited increased sociability and impaired prepulse inhibition. These results support a role for GRIP in social behavior and implicate GRIP1 variants in modulating autistic phenotype. PMID:21383172

  5. Dynamical Coordination of Hand Intrinsic Muscles for Precision Grip in Diabetes Mellitus.

    PubMed

    Li, Ke; Wei, Na; Cheng, Mei; Hou, Xingguo; Song, Jun

    2018-03-12

    This study investigated the effects of diabetes mellitus (DM) on dynamical coordination of hand intrinsic muscles during precision grip. Precision grip was tested using a custom designed apparatus with stable and unstable loads, during which the surface electromyographic (sEMG) signals of the abductor pollicis brevis (APB) and first dorsal interosseous (FDI) were recorded simultaneously. Recurrence quantification analysis (RQA) was applied to quantify the dynamical structure of sEMG signals of the APB and FDI; and cross recurrence quantification analysis (CRQA) was used to assess the intermuscular coupling between the two intrinsic muscles. This study revealed that the DM altered the dynamical structure of muscle activation for the FDI and the dynamical intermuscular coordination between the APB and FDI during precision grip. A reinforced feedforward mechanism that compensates the loss of sensory feedbacks in DM may be responsible for the stronger intermuscular coupling between the APB and FDI muscles. Sensory deficits in DM remarkably decreased the capacity of online motor adjustment based on sensory feedback, rendering a lower adaptability to the uncertainty of environment. This study shed light on inherent dynamical properties underlying the intrinsic muscle activation and intermuscular coordination for precision grip and the effects of DM on hand sensorimotor function.

  6. An ergonomic evaluation of manual Cleco plier designs: effects of rubber grip, spring recoil, and worksurface angle.

    PubMed

    You, Heecheon; Kumar, Anil; Young, Ronda; Veluswamy, Prabaharan; Malzahn, Don E

    2005-09-01

    The present study evaluated two design modifications (rubber grip and torsion spring) to the conventional manual Cleco pliers by electromyography (EMG), hand discomfort, and design satisfaction. This study also surveyed workers' satisfaction with selected design features of the pliers for ergonomic improvement. A two-way (plier design x worksurface angle) within-subject (nested within gender and hand size) design was employed. Eleven workers simulated the plier task in an adjustable workstation for different plier designs and worksurface angles (0 degrees , 60 degrees , and 90 degrees ). Lower EMG values were obtained for the pliers with rubber grip and at 60 degrees of worksurface angle. EMG values varied significantly between the participants, but showed low correlations (Spearman's rank correlation = -0.27 approximately -0.58) with their work experience with the pliers. The hand discomfort and design satisfaction evaluations identified that the grip span (max = 14.0 cm) and grip force requirement (peak = 220.5 N) of the current pliers need ergonomic modification. The present study shows the needs of both the ergonomic design of a hand tool and the training of a proper work method to control work-related musculoskeletal disorders at the workplace.

  7. Effect of molecular weight of polystyrensulfonic acid sodium salt polymers on the precipitation kinetics of sodium bicarbonate

    NASA Astrophysics Data System (ADS)

    Martínez-Cruz, Nancy; Carrillo-Romo, Felipe; Jaramillo-Vigueras, David

    2004-10-01

    This paper analyzes the effect of polystyrensulfonic acid sodium salt (NaPSS), obtained by kinetic precipitation from solutions of polymers of molecular weight 245 000 and 38 000 g mol-1 in sodium bicarbonate (NaHCO3) itself precipitated from synthetic brine. Crystal size, shape and the additive adsorbed are reported. X shaped and hexagonal prisms crystals with different aspect ratios were obtained. The results show that with increasing polymer concentration the crystal size decreases, from 0.27 to 0.48 mm. Additionally, the higher molecular weight polymer shows both higher adsorption capacity and higher crystal habit modification. Crystal shape patterns were similar for both polymers; however, the higher molecular weight material induced changes at lower concentration. It was observed that the precipitation rate reached a minimum with increasing additive concentration.

  8. Parametric study of solar thermal rocket nozzle performance

    NASA Technical Reports Server (NTRS)

    Pearson, J. Boise; Landrum, D. Brian; Hawk, Clark W.

    1995-01-01

    This paper details a numerical investigation of performance losses in low-thrust solar thermal rocket nozzles. The effects of nozzle geometry on three types of losses were studied; finite rate dissociation-recombination kinetic losses, two dimensional axisymmetric divergence losses, and compressible viscous boundary layer losses. Short nozzle lengths and supersonic flow produce short residence times in the nozzle and a nearly frozen flow, resulting in large kinetic losses. Variations in geometry have a minimal effect on kinetic losses. Divergence losses are relatively small, and careful shaping of the nozzle can nearly eliminate them. The boundary layer in these small nozzles can grow to a major fraction of nozzle radius, and cause large losses. These losses are attributed to viscous drag on the nozzle walls and flow blockage by the boundary layer, especially in the throat region. Careful shaping of the nozzle can produce a significant reduction in viscous losses.

  9. GRIP Experiment 2010

    NASA Image and Video Library

    2010-08-14

    Errol Korn, lower left, explains the dropsonde experiment to Janel Thomas, a University of Maryland Baltimore County (UMBC) graduate student, seated, as Bob Pasken, standing left, and Jeff Halverson, a GRIP project scientist from UMBC, look on inside NASA's DC-8 airplane, at Fort Lauderdale International Airport in Fort Lauderdale, Fla., Sunday, Aug. 15, 2010. The Genesis and Rapid Intensification Processes (GRIP) experiment is a NASA Earth science field experiment in 2010 that is being conducted to better understand how tropical storms form and develop into major hurricanes. Photo Credit: (NASA/Paul E. Alers)

  10. ELECTROMAGNETIC APPARATUS FOR MOVING A ROD

    DOEpatents

    Young, J.N.

    1958-04-22

    An electromagnetic apparatus for moving a rod-like member in small steps in either direction is described. The invention has particular application in the reactor field where the reactor control rods must be moved only a small distance and where the use of mechanical couplings is impractical due to the high- pressure seals required. A neutron-absorbing rod is mounted in a housing with gripping uaits that engage the rod, and coils for magnetizing the gripping units to make them grip, shift, and release the rod are located outside the housing.

  11. Effect of Low-Level Laser Therapy and Strength Training Protocol on Hand Grip by Dynamometry

    PubMed Central

    Barbosa, Rafael; Marcolino, Alexandre; Souza, Vitor; Bertolino, Guilherme; Fonseca, Marisa; Guirro, Rinaldo

    2017-01-01

    Introduction: The purpose of this study was to investigate the effect of low-level laser therapy (LLLT) – 660 nm and 904 nm - before grip strength protocol in healthy subjects. Methods: The study included 45 healthy volunteers with an average age of 22.7 (±1.4) years, subdivided into the following groups, control group: grip strength training associated with placebo LLLT; 660 nm group: LLLT (660 nm, 20 J/cm2, power of 30 mW, and beam area of 0.06 cm2, continuous, energy 1.2 J, and exposure time 40 seconds per point) before grip strength training and 904 nm group: LLLT (904 nm, 10 J/cm2, peak power of 70 W and 0.13 cm2 beam area, with pulsed beam 9.500 Hz and 30 seconds of exposure time per point and emitted energy 1.2 J) before grip strength training. The LLLT was timed to contact 10 points located in the region of the superficial and deep flexor muscles of the fingers, with a total energy of 12.0 J per session. For the strength training protocol, the volunteer exercised their fingers with the dominant hand on a small table, elbow flexed at 90°, forearm in neutral, using a light extension handle. The Oxford protocol was performed during four weeks. The grip strength was assessed using a dynamometer (Jamar™). The data were evaluated by the analysis of variance (ANOVA) statistical method. Results: In the comparison of intragroup evaluation, only the 904 nm group showed a difference compared to the baseline assessment after 4 weeks (P < 0.05), in the final intergroup evaluation, a difference was observed in the comparison between the control and 904 nm groups Conclusion: In conclusion, LLLT (904 nm) applied before resistance training was effective in gaining grip strength when compared to LLLT (660 nm) and isolated strength training after 4 weeks. PMID:29123629

  12. Spacecraft Observations and Analytic Theory of Crescent-Shaped Electron Distributions in Asymmetric Magnetic Reconnection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Egedal, J.; Le, A.; Daughton, W.

    Supported by a kinetic simulation, we derive in this paper an exclusion energy parametermore » $${\\mathcal{E}}_{X}$$ providing a lower kinetic energy bound for an electron to cross from one inflow region to the other during magnetic reconnection. As by a Maxwell demon, only high-energy electrons are permitted to cross the inner reconnection region, setting the electron distribution function observed along the low-density side separatrix during asymmetric reconnection. Finally, the analytic model accounts for the two distinct flavors of crescent-shaped electron distributions observed by spacecraft in a thin boundary layer along the low-density separatrix.« less

  13. Spacecraft Observations and Analytic Theory of Crescent-Shaped Electron Distributions in Asymmetric Magnetic Reconnection

    DOE PAGES

    Egedal, J.; Le, A.; Daughton, W.; ...

    2016-10-24

    Supported by a kinetic simulation, we derive in this paper an exclusion energy parametermore » $${\\mathcal{E}}_{X}$$ providing a lower kinetic energy bound for an electron to cross from one inflow region to the other during magnetic reconnection. As by a Maxwell demon, only high-energy electrons are permitted to cross the inner reconnection region, setting the electron distribution function observed along the low-density side separatrix during asymmetric reconnection. Finally, the analytic model accounts for the two distinct flavors of crescent-shaped electron distributions observed by spacecraft in a thin boundary layer along the low-density separatrix.« less

  14. Kinetics modeling of precipitation with characteristic shape during post-implantation annealing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Kun-Dar, E-mail: kundar@mail.nutn.edu.tw; Chen, Kwanyu

    2015-11-15

    In this study, we investigated the precipitation with characteristic shape in the microstructure during post-implantation annealing via a theoretical modeling approach. The processes of precipitates formation and evolution during phase separation were based on a nucleation and growth mechanism of atomic diffusion. Different stages of the precipitation, including the nucleation, growth and coalescence, were distinctly revealed in the numerical simulations. In addition, the influences of ion dose, temperature and crystallographic symmetry on the processes of faceted precipitation were also demonstrated. To comprehend the kinetic mechanism, the simulation results were further analyzed quantitatively by the Kolmogorov-Johnson-Mehl-Avrami (KJMA) equation. The Avrami exponentsmore » obtained from the regression curves varied from 1.47 to 0.52 for different conditions. With the increase of ion dose and temperature, the nucleation and growth of precipitations were expedited in accordance with the shortened incubation time and the raised coefficient of growth rate. A miscellaneous shape of precipitates in various crystallographic symmetry systems could be simulated through this anisotropic model. From the analyses of the kinetics, more fundamental information about the nucleation and growth mechanism of faceted precipitation during post-implantation annealing was acquired for future application.« less

  15. Fastener starter tool

    NASA Technical Reports Server (NTRS)

    Chandler, Faith T. (Inventor); Arnett, Michael C. (Inventor); Garton, Harry L. (Inventor); Valentino, William D. (Inventor)

    2003-01-01

    A fastener starter tool includes a number of spring retention fingers for retaining a small part, or combination of parts. The tool has an inner housing, which holds the spring retention fingers, a hand grip, and an outer housing configured to slide over the inner housing and the spring retention fingers toward and away from the hand grip, exposing and opening, or respectively, covering and closing, the spring retention fingers. By sliding the outer housing toward (away from) the hand grip, a part can be released from (retained by) the tool. The tool may include replaceable inserts, for retaining parts, such as screws, and configured to limit the torque applied to the part, to prevent cross threading. The inner housing has means to transfer torque from the hand grip to the insert. The tool may include replaceable bits, the inner housing having means for transferring torque to the replaceable bit.

  16. Average grip strength: a meta-analysis of data obtained with a Jamar dynamometer from individuals 75 years or more of age.

    PubMed

    Bohannon, Richard W; Bear-Lehman, Jane; Desrosiers, Johanne; Massy-Westropp, Nicola; Mathiowetz, Virgil

    2007-01-01

    Although strength diminishes with age, average values for grip strength have not been available heretofore for discrete strata after 75 years. The purpose of this meta-analysis was to provide average values for the left and right hands of men and women 75-79, 80-84, 85-89, and 90-99 years. Contributing to the analysis were 7 studies and 739 subjects with whom the Jamar dynamometer and standard procedures were employed. Based on the analysis, average values for the left and right hands of men and women in each age stratum were derived. The derived values can serve as a standard of comparison for individual patients. An individual whose grip strength is below the lower limit of the confidence intervals of each stratum can be confidently considered to have less than average grip strength.

  17. GRIP Experiment 2010

    NASA Image and Video Library

    2017-12-08

    Errol Korn, lower left, explains the dropsonde experiment to Janel Thomas, a University of Maryland Baltimore County (UMBC) graduate student, seated, as Bob Pasken, standing left, and Jeff Halverson, a GRIP project scientist from UMBC, look on inside NASA's DC-8 airplane, at Fort Lauderdale International Airport in Fort Lauderdale, Fla., Sunday, Aug. 15, 2010. The Genesis and Rapid Intensification Processes (GRIP) experiment is a NASA Earth science field experiment in 2010 that is being conducted to better understand how tropical storms form and develop into major hurricanes. Credit: NASA/Paul E. Alers To read more about the GRIP Mission go here or here for an interactive feature NASA Goddard Space Flight Center is home to the nation's largest organization of combined scientists, engineers and technologists that build spacecraft, instruments and new technology to study the Earth, the sun, our solar system, and the universe. Follow us on Twitter Join us on Facebook

  18. Variation in the ciliary neurotrophic factor gene and muscle strength in older Caucasian women.

    PubMed

    Arking, Dan E; Fallin, Daniele M; Fried, Linda P; Li, Tao; Beamer, Brock A; Xue, Qian Li; Chakravarti, Aravinda; Walston, Jeremy

    2006-05-01

    To determine whether genetic variants in the ciliary neurotrophic factor (CNTF) gene are associated with muscle strength in older women. Cross-sectional analysis of baseline data from the Women's Health and Aging Studies I (1992) and II (1994), complementary population-based studies. Twelve contiguous ZIP code areas in Baltimore, Maryland. Three hundred sixty-three Caucasian, community-dwelling women aged 70 to 79. Participants were genotyped at the CNTF locus for eight single nucleotide polymorphisms (SNPs), including the null allele rs1800169. The dependent variables were grip strength and the frailty syndrome, identified as presence of three or more of five frailty indicators (weakness, slowness, weight loss, low physical activity, exhaustion). In addition to genotypes, independent variables of body mass index (BMI) and osteoarthritis of the hands were included. Using multivariate linear regression, single SNP analysis identified five SNPs significantly associated with grip strength (P<.05), after adjusting for age, BMI, and osteoarthritis. Haplotype analysis was performed, and a single haplotype associated with grip strength was identified (P<.01). The rs1800169 null allele fully explained the association between this haplotype and grip strength under a recessive model, with individuals homozygous for the null allele exhibiting a 3.80-kg lower (95% confidence interval=1.01-6.58) grip strength. No association was seen between the CNTF null allele and frailty. Individuals homozygous for the CNTF null allele had significantly lower grip strength but did not exhibit overt frailty. Larger prospective studies are needed to confirm this finding and extend it to additional populations.

  19. Influence of finger and mouth action observation on random number generation: an instance of embodied cognition for abstract concepts.

    PubMed

    Grade, Stéphane; Badets, Arnaud; Pesenti, Mauro

    2017-05-01

    Numerical magnitude and specific grasping action processing have been shown to interfere with each other because some aspects of numerical meaning may be grounded in sensorimotor transformation mechanisms linked to finger grip control. However, how specific these interactions are to grasping actions is still unknown. The present study tested the specificity of the number-grip relationship by investigating how the observation of different closing-opening stimuli that might or not refer to prehension-releasing actions was able to influence a random number generation task. Participants had to randomly produce numbers after they observed action stimuli representing either closure or aperture of the fingers, the hand or the mouth, or a colour change used as a control condition. Random number generation was influenced by the prior presentation of finger grip actions, whereby observing a closing finger grip led participants to produce small rather than large numbers, whereas observing an opening finger grip led them to produce large rather than small numbers. Hand actions had reduced or no influence on number production; mouth action influence was restricted to opening, with an overproduction of large numbers. Finally, colour changes did not influence number generation. These results show that some characteristics of observed finger, hand and mouth grip actions automatically prime number magnitude, with the strongest effect for finger grasping. The findings are discussed in terms of the functional and neural mechanisms shared between hand actions and number processing, but also between hand and mouth actions. The present study provides converging evidence that part of number semantics is grounded in sensory-motor mechanisms.

  20. Impact of mild versus moderate intensity aerobic walking exercise training on markers of bone metabolism and hand grip strength in moderate hemophilic A patients.

    PubMed

    Al-Sharif, Fadwa Al-Ghalib; Al-Jiffri, Osama Hussien; El-Kader, Shehab Mahmoud Abd; Ashmawy, Eman Mohamed

    2014-03-01

    Patients with hemophilia A have low bone density than healthy controls. It is now widely recognized that physical activity and sports are beneficial for patients with hemophilia. To compare the effects of mild and moderate intensity treadmill walking exercises on markers of bone metabolism and hand grip strength in male patients with moderate hemophilia A. Fifty male patients with moderate hemophilia, and age range from 25 to 45 years. The subjects were randomly assigned into 2 equal groups; the first group (A) received moderate intensity aerobic exercise training. The second group (B) received mild intensity aerobic exercise training. There was a 32.1% and 24.8% increase in mean values of serum calcium and hand grip strength respectively and 22.7 % reduction in mean values of parathyroid hormone in moderate exercise training group (A). While there was a 15.1 % and 15 % increase in mean values of Serum Calcium and Hand grip strength respectively and 10.3 % reduction in mean values of parathyroid hormone in mild exercise training group(B). The mean values of serum calcium and hand grip strength were significantly increased, while the mean values of parathyroid hormone were significantly decreased in both groups . There were significant differences between mean levels of the investigated parameters in group (A) and group (B) after treatment. Moderate intensity aerobic exercise training on treadmill is appropriate to improve markers of bone metabolism and hand grip strength in male patients with hemophilia A.

  1. Influences of load characteristics on impaired control of grip forces in patients with cerebellar damage.

    PubMed

    Brandauer, B; Timmann, D; Häusler, A; Hermsdörfer, J

    2010-02-01

    Various studies showed a clear impairment of cerebellar patients to modulate grip force in anticipation of the loads resulting from movements with a grasped object. This failure corroborated the theory of internal feedforward models in the cerebellum. Cerebellar damage also impairs the coordination of multiple-joint movements and this has been related to deficient prediction and compensation of movement-induced torques. To study the effects of disturbed torque control on feedforward grip-force control, two self-generated load conditions with different demands on torque control-one with movement-induced and the other with isometrically generated load changes-were directly compared in patients with cerebellar degeneration. Furthermore the cerebellum is thought to be more involved in grip-force adjustment to self-generated loads than to externally generated loads. Consequently, an additional condition with externally generated loads was introduced to further test this hypothesis. Analysis of 23 patients with degenerative cerebellar damage revealed clear impairments in predictive feedforward mechanisms in the control of both self-generated load types. Besides feedforward control, the cerebellar damage also affected more reactive responses when the externally generated load destabilized the grip, although this impairment may vary with the type of load as suggested by control experiments. The present findings provide further support that the cerebellum plays a major role in predictive control mechanisms. However, this impact of the cerebellum does not strongly depend on the nature of the load and the specific internal forward model. Contributions to reactive (grip force) control are not negligible, but seem to be dependent on the physical characteristics of an externally generated load.

  2. Variation in work tasks in relation to pinch grip strength among middle-aged female dentists.

    PubMed

    Ding, Hebo; Leino-Arjas, Päivi; Murtomaa, Heikki; Takala, Esa-Pekka; Solovieva, Svetlana

    2013-11-01

    We aimed to investigate the relationship of task variation during dental work history with pinch grip strength among dentists. We measured pinch grip strength among 295 female Finnish dentists aged 45-63 years. Variation in dental work tasks during work history was empirically defined by cluster analysis. Three clusters of task variation emerged: low (most work time in restoration treatment/endodontics), moderate (about 50% in the former and 50% in prosthodontics/periodontics/surgery), and high (variable tasks including administrative duties). Hand radiographs were examined for the presence of OA in the wrist and each joint of the 1-3rd fingers. Information on hand-loading leisure-time activities, and joint pain was obtained by questionnaire. Glove size was used as a proxy for hand size. BMI (kg/m2) was based on measured weight and self-reported height. Dentists with low variation of work task history had an increased risk of low pinch grip strength in the right hand (OR 2.3, 95% CI 1.2-4.3), but not in the left (1.13, 0.62-2.08), compared to dentists with high task variation, independent of age, hand size, hand-loading leisure-time activities, BMI and symptomatic hand OA. The dentists with the most hand-loading tasks were at an increased risk of low pinch grip strength, independent of e.g. symptomatic hand OA. It is advisable among dentists to perform as diverse work tasks as possible to reduce the risk of decreased pinch grip strength. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. Coarsening of Ni(3)Si precipitates in binary Ni-Si alloys

    NASA Astrophysics Data System (ADS)

    Cho, Jin-Hoon

    The coarsening behavior of coherent gammasp'\\ (Nisb3Si) precipitates with volume fractions, f, ranging from 0.017 to 0.32 in binary Ni-Si alloys was investigated. All of the alloys were aged at 650sp° C for times as long as 2760 h and measurements were made of the kinetics of coarsening, particle size distributions and the evolution of particle morphologies using transmission electron microscopy. The kinetics of solute depletion were investigated using measurements of the ferromagnetic Curie temperature. We successfully overcame the difficulties in obtaining uniform spatial distributions of precipitates at small f by employing an up-quenching treatment; alloys with f less than 0.1 were pre-aged at 530sp° C prior to re-aging at the normal aging temperature of 650sp° C. Almost identical coarsening behavior exhibited by an alloy subjected to both isothermal and up-quenching treatments confirm that the up-quenching treatments do not affect any aspect of the coarsening behavior. Consistent with previous studies, the particles are spherical in shape when small and evolve to a cuboidal shape, with flat faces parallel to {}, as they grow. This shape transition was characterized quantitatively by analyzing the intensity distributions of Fast Fourier Transform spectra generated from the digitized images of TEM micrographs. The precipitates display no tendency towards becoming plate-shaped and they resist coalescence even at the largest sizes, which approach 400 nm in diameter at 2760 h of aging for higher volume fraction alloys. For f < 0.1, the kinetics of coarsening and solute depletion as well as the standard deviation of the particle size distributions decrease as f increases. This anomalous behavior has been documented previously by other investigators, but is contrary to the predictions of theories that incorporate the volume fraction effect in coarsening kinetics. We find no convincing evidence to suggest that f influences any aspect of the coarsening behavior at larger f. It is suggested that the lack of agreement between the volume fraction effects observed experimentally and those predicted theoretically stems from the elastic interactions having a strong influence on the kinetics of coarsening, effectively counteracting the accelerating influence of f on the coarsening kinetics predicted by the theories.

  4. Cyclic Voltammetric Wave-Shapes for Microdisk Electrodes: Coupled Effects of Solution Resistance, Double-Layer Capacitance, and Finite Electrochemical Kinetics

    DTIC Science & Technology

    1991-05-01

    vaveshapea. While the use of high scan rates enhances the effect of electrode kinetics upon the voltametry , the deleterious coupled influence of pa 20...waveshapes. While the use of high scan rates enhances the effect of electrode kinetics upon the voltametry , the deleterious coupled influence of P...2 1 󈧚 Aoki et al have in- 23 vestigated linear sweep voltammetry at microdisks in the reversible case, and Zoski and co-workers have developed

  5. Kinetic parameters and structural variations in Cu-Al-Mn and Cu-Al-Mn-Mg shape memory alloys

    NASA Astrophysics Data System (ADS)

    Canbay, Canan Aksu

    2017-02-01

    In this work polycrystalline Cu-Al-Mn and Cu-Al-Mn-Mg SMAs were fabricated by arc melting. The thermal analysis was made to determine the characteristic transformation temperatures of the samples and kinetic parameters. Also the effect of Mg on transformation temperatures and kinetic parameters detected. The structural analysis was made to designate the diffraction planes of martensite phase at room temperature and this was supported by optical measurement observations.

  6. Nanowire growth from the viewpoint of the thin film polylayer growth theory

    NASA Astrophysics Data System (ADS)

    Kashchiev, Dimo

    2018-03-01

    The theory of polylayer growth of thin solid films is employed for description of the growth kinetics of single-crystal nanowires. Expressions are derived for the dependences of the height h and radius r of a given nanowire on time t, as well as for the h(r) dependence. These dependences are applicable immediately after the nanowire nucleation on the substrate and thus include the period during which the nucleated nanowire changes its shape from that of cap to that of column. The analysis shows that the nanowire cap-to-column shape transition is continuous and makes it possible to kinetically define the nanowire shape-transition radius by means of the nanowire radial and axial growth rates. The obtained h(t), r(t) and h(r) dependences are found to provide a good description of available experimental data for growth of self-nucleated GaN nanowires by the vapor-solid mechanism.

  7. In the Grip of the Scorpion Claw

    NASA Image and Video Library

    2010-09-21

    Gripped in the claw of the constellation Scorpius sits the reflection nebula DG 129, a cloud of gas and dust that reflects light from nearby, bright stars. This infrared view of the nebula was captured by NASA Wide-field Infrared Survey Explorer.

  8. 78 FR 47531 - Airworthiness Directives; Various Restricted Category Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-06

    ... Technology, Inc.; Hagglund Helicopters, LLC (previously Western International Aviation, Inc.); International.... This AD requires creating a component history card or equivalent record for each main rotor grip (grip....); California Department of Forestry; Garlick Helicopters, Inc.; Global Helicopter Technology, Inc.; Hagglund...

  9. GRIP Experiment 2010

    NASA Image and Video Library

    2010-08-14

    Jeffrey Beyon, lower right, and Paul Joseph Petzar, right, researchers from NASA's Langley Research Center, speak with Ramesh Kakar right, of the NASA Earth Science Division as they work with DAWN Air Data Acquisition and Processing software aboard NASA's DC-8 research aircraft, Sunday, Aug. 15, 2010, in support of the GRIP experiment at Fort Lauderdale International Airport in Fort Lauderdale, Fla. The Genesis and Rapid Intensification Processes (GRIP) experiment is a NASA Earth science field experiment in 2010 that is being conducted to better understand how tropical storms form and develop into major hurricanes. Photo Credit: (NASA/Paul E. Alers)

  10. Method and apparatus for tensile testing of metal foil

    NASA Technical Reports Server (NTRS)

    Wade, O. W. (Inventor)

    1976-01-01

    A method for obtaining accurate and reproducible results in the tensile testing of metal foils in tensile testing machines is described. Before the test specimen are placed in the machine, foil side edges are worked until they are parallel and flaw free. The specimen are also aligned between and secured to grip end members. An aligning apparatus employed in the method is comprised of an alignment box with a longitudinal bottom wall and two upright side walls, first and second removable grip end members at each end of the box, and a means for securing the grip end members within the box.

  11. Responsiveness of performance-based outcome measures for mobility, balance, muscle strength and manual dexterity in adults with myotonic dystrophy type 1.

    PubMed

    Kierkegaard, Marie; Petitclerc, Émilie; Hébert, Luc J; Mathieu, Jean; Gagnon, Cynthia

    2018-02-28

    To assess changes and responsiveness in outcome measures of mobility, balance, muscle strength and manual dexterity in adults with myotonic dystrophy type 1. A 9-year longitudinal study conducted with 113 patients. The responsiveness of the Timed Up and Go test, Berg Balance Scale, quantitative muscle testing, grip and pinch-grip strength, and Purdue Pegboard Test was assessed using criterion and construct approaches. Patient-reported perceived changes (worse/stable) in balance, walking, lower-limb weakness, stair-climbing and hand weakness were used as criteria. Predefined hypotheses about expected area under the receiver operating characteristic curves (criterion approach) and correlations between relative changes (construct approach) were explored. The direction and magnitude of median changes in outcome measures corresponded with patient-reported changes. Median changes in the Timed Up and Go test, grip strength, pinch-grip strength and Purdue Pegboard Test did not, in general, exceed known measurement errors. Most criterion (72%) and construct (70%) approach hypotheses were supported. Promising responsiveness was found for outcome measures of mobility, balance and muscle strength. Grip strength and manual dexterity measures showed poorer responsiveness. The performance-based outcome measures captured changes over the 9-year period and responsiveness was promising. Knowledge of measurement errors is needed to interpret the meaning of these longitudinal changes.

  12. The relationships between hand coupling force and vibration biodynamic responses of the hand-arm system.

    PubMed

    Pan, Daniel; Xu, Xueyan S; Welcome, Daniel E; McDowell, Thomas W; Warren, Christopher; Wu, John; Dong, Ren G

    2018-06-01

    This study conducted two series of experiments to investigate the relationships between hand coupling force and biodynamic responses of the hand-arm system. In the first experiment, the vibration transmissibility on the system was measured as a continuous function of grip force while the hand was subjected to discrete sinusoidal excitations. In the second experiment, the biodynamic responses of the system subjected to a broadband random vibration were measured under five levels of grip forces and a combination of grip and push forces. This study found that the transmissibility at each given frequency increased with the increase in the grip force before reaching a maximum level. The transmissibility then tended to plateau or decrease when the grip force was further increased. This threshold force increased with an increase in the vibration frequency. These relationships remained the same for both types of vibrations. The implications of the experimental results are discussed. Practitioner Summary: Shocks and vibrations transmitted to the hand-arm system may cause injuries and disorders of the system. How to take hand coupling force into account in the risk assessment of vibration exposure remains an important issue for further studies. This study is designed and conducted to help resolve this issue.

  13. Grip strength and quality of life in the second half of life: hope as a moderator.

    PubMed

    Gum, Amber M; Segal-Karpas, Dikla; Avidor, Sharon; Ayalon, Liat; Bodner, Ehud; Palgi, Yuval

    2017-09-28

    The purpose of the current study was to investigate grip strength, hope, and their interaction as predictors of quality of life four years later in a nationally representative sample of older adults. Data were derived from the first (2005-2006) and second wave (2009) of the Israeli component of the Survey of Health Ageing and Retirement in Europe (SHARE; N = 344). Hope was measured by three items from the Hope   Scale, and quality of life was measured by the CASP-12 (Control, Autonomy, Self-Realization, and Pleasure). Multiple regression analyses were conducted. Grip strength at T1 predicted QoL in T2, but hope was not a significant predictor. Furthermore, hope moderated the effect of handgrip on QoL, such that the effect was weaker for higher levels of hope. As hypothesized, hope acted as a moderator, such that poor grip strength was associated with worse QoL for less hopeful older adults, but grip strength was not associated with QoL for more hopeful older adults. Findings are consistent with a theoretical conceptualization of hope as a buffer between physical challenges and negative outcomes like QoL. Encouraging a hopeful perspective could enhance QoL for older adults with decreased muscle strength.

  14. Handgrip and general muscular strength and endurance during prolonged bedrest with isometric and isotonic leg exercise training

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Starr, J. C.; Van Beaumont, W.; Convertino, V. A.

    1983-01-01

    Measurements of maximal grip strength and endurance at 40 percent max strength were obtained for 7 men 19-21 years of age, 1-2 days before and on the first recovery day during three 2-week bedrest (BR) periods, each separated by a 3-week ambulatory recovery period. The subjects performed isometric exercise (IME) for 1 hr/day, isotonic exercise (ITE) for 1 hr/day, and no exercise (NOE) in the three BR periods. It was found that the mean maximal grip strength was unchanged after all three BR periods. Mean grip endurance was found to be unchanged after IME and ITE training, but was significantly reduced after NOE. These results indicate that IME and ITE training during BR do not increase or decrease maximal grip strength, alghough they prevent loss of grip endurance, while the maximal strength of all other major muscle groups decreases in proportion to the length of BR to 70 days. The maximal strength reduction of the large muscle groups was found to be about twice that of the small muscle groups during BR. In addition, it is shown that changes in maximal strength after spaceflight, BR, or water immersion deconditioning cannot be predicted from changes in submaximal or maximal oxygen uptake values.

  15. Kinematic analyses of the golf swing hub path and its role in golfer/club kinetic transfers.

    PubMed

    Nesbit, Steven M; McGinnis, Ryan

    2009-01-01

    This study analyzed the fundamental geometric and kinematic characteristics of the swing hub path of the golf shot for four diverse subjects. In addition, the role of the hub path geometry in transferring the kinetic quantities from the golfer to the club were investigated. The hub path was found to have a complex geometry with significantly changing radii, and a constantly moving center-of-curvature during the downswing for all subjects. While the size and shape of the hub path differed considerably among the subjects, a three phase radius-based pattern was revealed that aligned with distinct stages of the downswing. Artificially controlling and optimizing the hub path of the better golfer in the group indicated that a non-circular hub path was superior to a constant radius path in minimizing the kinetic loading while generating the highest possible club head velocity. The shape and purpose of the hub path geometry appears to result from a complex combination of achieving equilibrium between the golfer and the club, and a purposeful configuring of the path to control the outward movement of the club while minimizing the kinetic loading on the golfer yet transferring the maximum kinetic quantities to the club. Describing the downswing relative to the hub path phasing is presented and was found to be informative since the phases align with significant swing, kinetic and kinematic markers. These findings challenge golf swing modeling methodologies which fix the center-of-curvature of the hub path thus constraining it to constant radius motion. Key pointsThe golf swing hub path was found to have a complex geometry with significantly changing radii, and a constantly moving center-of-curvature during the downswing.The hub path differed considerably among subjects, however a three phase radius-based pattern was revealed that aligned with distinct stages of the downswing.The shape and purpose of the hub path geometry appears to result from a complex combination of achieving equilibrium between the golfer and the club, and a purposeful configuring of the path to control the outward movement of the club while minimizing the kinetic loading on the golfer yet transferring the maximum kinetic quantities to the club.

  16. Impact of cell shape in hierarchically structured plant surfaces on the attachment of male Colorado potato beetles (Leptinotarsa decemlineata)

    PubMed Central

    Seidel, Robin; Bohn, Holger Florian; Speck, Thomas

    2012-01-01

    Summary Plant surfaces showing hierarchical structuring are frequently found in plant organs such as leaves, petals, fruits and stems. In our study we focus on the level of cell shape and on the level of superimposed microstructuring, leading to hierarchical surfaces if both levels are present. While it has been shown that epicuticular wax crystals and cuticular folds strongly reduce insect attachment, and that smooth papillate epidermal cells in petals improve the grip of pollinators, the impact of hierarchical surface structuring of plant surfaces possessing convex or papillate cells on insect attachment remains unclear. We performed traction experiments with male Colorado potato beetles on nine different plant surfaces with different structures. The selected plant surfaces showed epidermal cells with either tabular, convex or papillate cell shape, covered either with flat films of wax, epicuticular wax crystals or with cuticular folds. On surfaces possessing either superimposed wax crystals or cuticular folds we found traction forces to be almost one order of magnitude lower than on surfaces covered only with flat films of wax. Independent of superimposed microstructures we found that convex and papillate epidermal cell shapes slightly enhance the attachment ability of the beetles. Thus, in plant surfaces, cell shape and superimposed microstructuring yield contrary effects on the attachment of the Colorado potato beetle, with convex or papillate cells enhancing attachment and both wax crystals or cuticular folds reducing attachment. However, the overall magnitude of traction force mainly depends on the presence or absence of superimposed microstructuring. PMID:22428097

  17. Morphology and Kinetics of Growth of CaCO3 Precipitates Formed in Saline Water at 30°C

    NASA Astrophysics Data System (ADS)

    Sui, Xin; Wang, Baohui; Wu, Haiming

    2018-02-01

    The crystallization kinetics and morphology of CaCO3 crystals precipitated from the high salinity oilfield water were studied. The crystallization kinetics measurements show that nucleation and nuclei growth obey the first order reaction kinetics. The induction period of precipitation is extended in the high salinity solutions. Morphological studies show that impurity ions remain mostly in the solution phase instead of filling the CaCO3 crystal lattice. The morphology of CaCO3 precipitates can be changed from a smooth surface (calcite) to rough spheres (vaterite), and spindle rod bundles, or spherical, ellipsoid, flowers, plates and other shapes (aragonite).

  18. Reinforcement for Stretch Formed Sheet Metal

    NASA Technical Reports Server (NTRS)

    Lea, J. B.; Baxter, C. R.

    1983-01-01

    Tearing of aluminum sheet metal durinng stretch forming prevented by flame spraying layer of aluminum on edges held in stretch-forming machine. Technique improves grip of machine on metal and reinforced sheet better able to with stand concentration of force in vicinity of grips.

  19. Kinetically-controlled template-free synthesis of hollow silica micro-/nanostructures with unusual morphologies

    NASA Astrophysics Data System (ADS)

    Zhang, An-Qi; Li, Hui-Jun; Qian, Dong-Jin; Chen, Meng

    2014-04-01

    We report a kinetically-controlled template-free room-temperature production of hollow silica materials with various novel morphologies, including tubes, crutches, ribbons, bundles and bells. The obtained products, which grew in a well-controlled manner, were monodispersed in shape and size. The role of ammonia, sodium citrate, polyvinylpyrrolidone, chloroauric acid and NaCl in shape control is discussed in detail. The oriented growth of these micro-/nanostructures directed by reverse micelles followed a solution-solution-solid (SSS) mechanism, similar to the classic vapor-liquid-solid mechanism. The evolution processes of silica rods, tubes, crutches, bundles and bells were recorded using transmission electron microscopy to prove the SSS mechanism.

  20. Hand function is altered in individuals with a history of illicit stimulant use.

    PubMed

    Pearson-Dennett, Verity; Flavel, Stanley C; Wilcox, Robert A; Thewlis, Dominic; Vogel, Adam P; White, Jason M; Todd, Gabrielle

    2014-01-01

    Use of illicit stimulant drugs such as methamphetamine, cocaine, and ecstasy are a significant worldwide problem. However, little is known about the effect of these drugs on movement. The aim of the current study was to investigate hand function in adults with a history of illicit stimulant use. We hypothesized that prior use of illicit stimulant drugs is associated with abnormal manipulation of objects. The study involved 22 subjects with a history of illicit stimulant use (aged 29±8 yrs; time since last use: 1.8±4.0 yrs) and two control groups comprising 27 non-drug users (aged 25±8 yrs) and 17 cannabis users with no history of stimulant use (aged 22±5 yrs). Each subject completed screening tests (neuropsychological assessment, medical history questionnaire, lifetime drug history questionnaire, and urine drug screen) prior to gripping and lifting a light-weight object with the dominant right hand. Horizontal grip force, vertical lift force, acceleration, and first dorsal interosseus electromyographic (EMG) activity were recorded during three trials. In trial one, peak grip force was significantly greater in the stimulant group (12.8±3.9 N) than in the control groups (non-drug: 10.3±4.6 N; cannabis: 9.4±2.9 N, P<0.022). However, peak grip force did not differ between groups in trials two and three. The results suggest that individuals with a history of stimulant use overestimate the grip force required to manipulate a novel object but, are able to adapt grip force in subsequent lifts. The results suggest that movement dysfunction may be an unrecognized consequence of illicit stimulant use.

  1. Handgrip strength and its prognostic value for mortality in Moscow, Denmark, and England

    PubMed Central

    Demakakos, Panayotes; Shkolnikova, Maria; Thinggaard, Mikael; Vaupel, James W.; Christensen, Kaare; Shkolnikov, Vladimir M.

    2017-01-01

    Background This study compares handgrip strength and its association with mortality across studies conducted in Moscow, Denmark, and England. Materials The data collected by the Study of Stress, Aging, and Health in Russia, the Study of Middle-Aged Danish Twins and the Longitudinal Study of Aging Danish Twins, and the English Longitudinal Study of Ageing was utilized. Results Among the male participants, the age-standardized grip strength was 2 kg and 1 kg lower in Russia than in Denmark and in England, respectively. The age-standardized grip strength among the female participants was 1.9 kg and 1.6 kg lower in Russia than in Denmark and in England, respectively. In Moscow, a one-kilogram increase in grip strength was associated with a 4% (hazard ratio [HR] = 0.96, 95% confidence interval [CI]: 0.94, 0.99) reduction in mortality among men and a 10% (HR = 0.90, 95%CI: 0.86, 0.94) among women. Meanwhile, a one-kilogram increase in grip strength was associated with a 6% (HR = 0.94, 95%CI: 0.93, 0.95) and an 8% (HR = 0.92, 95%CI: 0.90, 0.94) decrease in mortality among Danish men and women, respectively, and with a 2% (HR = 0.98, 95%CI: 0.97, 0.99) and a 3% (HR = 0.97, 95%CI: 0.95, 0.98) reduction in mortality among the English men and women, respectively. Conclusion The study suggests that, although absolute grip strength values appear to vary across the Muscovite, Danish, and English samples, the degree to which grip strength is predictive of mortality is comparable across national populations with diverse socioeconomic and health profiles and life expectancy levels. PMID:28863174

  2. From regained function to daily use: experiences of surgical reconstruction of grip in people with tetraplegia.

    PubMed

    Wangdell, Johanna; Carlsson, Gunnel; Friden, Jan

    2014-01-01

    To capture patients' relearning processes from regained function to improvements in daily life after grip reconstructive surgery in tetraplegia. Eleven people with tetraplegia who underwent grip reconstructive surgery during February 2009 to March 2011. Qualitative interviews were conducted 7 to 17 months after surgery and analysed using grounded theory. Determination to reach a higher level of independence was the core concept to integrate regained function into daily life. There were 3 phases identified; "Initiate activity training," "Establish hand control in daily activities," and "Challenge dependence." Between the phases psychological stages occurred, first; "a belief in improved ability", and later in the process; "confidence in ability". The process to fully integrate regain function in daily life was described as long and time-consuming. However, the participants claimed it useful to do the skills training in their home environment, without long-term in clinic rehabilitation. Relearning activities in daily life after a grip reconstruction is a time-consuming and demanding process. It includes skills training, mental strategies and psychological stages together with environmental and social factors. Accordingly, rehabilitation after grip reconstruction in tetraplegia should focus on both grip skills and psychological stages, to encourage that patient's keep their determination and achieve greater independence. Implications for Rehabilitation There is a stepwise process to transform improved function into daily use. The most important factor to transform improved function into daily use was motivation to reach a higher independence. Other important factors were; skills training, use of individual learning strategies, belief and confidence in personal ability, social and environmental factors. There was a long and demanding process to fully transform the improved function into daily use. The participants preferred to do activity training in the specific environment, usually at home.

  3. Hand Function is Altered in Individuals with a History of Illicit Stimulant Use

    PubMed Central

    Pearson-Dennett, Verity; Flavel, Stanley C.; Wilcox, Robert A.; Thewlis, Dominic; Vogel, Adam P.; White, Jason M.; Todd, Gabrielle

    2014-01-01

    Use of illicit stimulant drugs such as methamphetamine, cocaine, and ecstasy are a significant worldwide problem. However, little is known about the effect of these drugs on movement. The aim of the current study was to investigate hand function in adults with a history of illicit stimulant use. We hypothesized that prior use of illicit stimulant drugs is associated with abnormal manipulation of objects. The study involved 22 subjects with a history of illicit stimulant use (aged 29±8 yrs; time since last use: 1.8±4.0 yrs) and two control groups comprising 27 non-drug users (aged 25±8 yrs) and 17 cannabis users with no history of stimulant use (aged 22±5 yrs). Each subject completed screening tests (neuropsychological assessment, medical history questionnaire, lifetime drug history questionnaire, and urine drug screen) prior to gripping and lifting a light-weight object with the dominant right hand. Horizontal grip force, vertical lift force, acceleration, and first dorsal interosseus electromyographic (EMG) activity were recorded during three trials. In trial one, peak grip force was significantly greater in the stimulant group (12.8±3.9 N) than in the control groups (non-drug: 10.3±4.6 N; cannabis: 9.4±2.9 N, P<0.022). However, peak grip force did not differ between groups in trials two and three. The results suggest that individuals with a history of stimulant use overestimate the grip force required to manipulate a novel object but, are able to adapt grip force in subsequent lifts. The results suggest that movement dysfunction may be an unrecognized consequence of illicit stimulant use. PMID:25545892

  4. Effect of cold air inhalation and isometric exercise on coronary blood flow and myocardial function in humans

    PubMed Central

    Muller, Matthew D.; Gao, Zhaohui; Drew, Rachel C.; Herr, Michael D.; Leuenberger, Urs A.

    2011-01-01

    The effects of cold air inhalation and isometric exercise on coronary blood flow are currently unknown, despite the fact that both cold air and acute exertion trigger angina in clinical populations. In this study, we used transthoracic Doppler echocardiography to measure coronary blood flow velocity (CBV; left anterior descending coronary artery) and myocardial function during cold air inhalation and handgrip exercise. Ten young healthy subjects underwent the following protocols: 5 min of inhaling cold air (cold air protocol), 5 min of inhaling thermoneutral air (sham protocol), 2 min of isometric handgrip at 30% of maximal voluntary contraction (grip protocol), and 5 min of isometric handgrip at 30% maximal voluntary contraction while breathing cold air (cold + grip protocol). Heart rate, blood pressure, inspired air temperature, CBV, myocardial function (tissue Doppler imaging), O2 saturation, and pulmonary function were measured. The rate-pressure product (RPP) was used as an index of myocardial O2 demand, whereas CBV was used as an index of myocardial O2 supply. Compared with the sham protocol, the cold air protocol caused a significantly higher RPP, but there was a significant reduction in CBV. The cold + grip protocol caused a significantly greater increase in RPP compared with the grip protocol (P = 0.045), but the increase in CBV was significantly less (P = 0.039). However, myocardial function was not impaired during the cold + grip protocol relative to the grip protocol alone. Collectively, these data indicate that there is a supply-demand mismatch in the coronary vascular bed when cold ambient air is breathed during acute exertion but myocardial function is preserved, suggesting an adequate redistribution of blood flow. PMID:21940852

  5. Anterior and Posterior Interosseous Neurectomy for the Treatment of Chronic Dynamic Instability of the Wrist

    PubMed Central

    Hofmeister, Eric P.; Moran, Steven L.

    2006-01-01

    The purpose of this study was to determine the results of combined anterior and posterior interosseous neurectomy (AIN/PIN) in patients with chronic wrist pain secondary to dynamic instability, and to determine the predictability of selective AIN/PIN blocks with respect to pain relief, grip strength, and outcome of the neurectomy. A prospectively accrued chronic wrist pain registry was undertaken. Inclusion criteria were patients with arthroscopically confirmed dynamic wrist instability who had undergone a diagnostic AIN/PIN injection, followed by a single dorsal incision neurectomy. All patients completed Disabilities of the Arm, Shoulder and Hand outcome questionnaires preoperatively and at intervals postoperatively. Pre- and postoperative range of motion, grip strength, and percentage pain relief were recorded. Over a 3-year period, 50 wrists (48 patients) were enrolled: average follow-up was 28 months (range: 24–42 months). The average improvement in grip strength after denervation was 16% (p = 0.076), the average improvement in subjective pain rating was 51% (p < 0.0001), and the average improvement in Disabilities of the Arm, Shoulder, and Hand scores was 15 points (p = 0.0039). Improvement of pain from diagnostic injections was not predictive of final improvement of pain; however, improvement in grip strength after diagnostic injections did correlate with improved grip strength after surgery. Lack of improvement in subjective pain rating or grip strength after diagnostic injection approached statistical significance. There was no decrease in range of motion postoperatively. Fourteen patients (16 wrists) failed as defined by need for subsequent surgery. The results of AIN/PIN neurectomy demonstrate that it may be an effective alternative to wrist salvage or reconstructive procedures within the first few years of follow-up. PMID:18780027

  6. Donor-site morbidity after pedicled TRAM breast reconstruction: a comparison of two different types of mesh.

    PubMed

    Sværdborg, Mille; Damsgaard, Tine Engberg

    2013-11-01

    Many different approaches have been used to minimize the risk of bulge or hernia formation when using autologous abdominal tissue for breast reconstruction. Studies have shown that further reinforcement of the abdominal wall using a mesh may decrease the complication rate.The current study included 40 consecutive patients having unilateral breast reconstruction with the pedicled transverse rectus abdominus musculocutaneous flap. The defect in the abdominal fascia was closed primarily and further reinforced using a Prolene mesh (Ethicon), n = 20, or using a self-fixating Parietex ProGrip mesh (Covidien), n = 20. The patients were examined at an outpatient consultation, with a minimum follow-up of 1 year and questioned about donor-site symptoms using a standardized questionnaire.Of the 20 patients in the Prolene group, 2 (10%) developed abdominal wall bulging, and of the 20 patients in the ProGrip group, 11 (55%) developed abdominal wall bulging (P = 0.006). In both the Prolene and the ProGrip group, most patients reported having continued donor-site symptoms at the time of the follow-up (70% and 80%, respectively); 15% and 30%, respectively, reported having symptoms that influenced their daily or physical activities (not a significant difference). All but 1 patient in our study reported being very happy with the reconstruction and would have done it again, had they known what they did at the time of the follow-up.We conclude that the self-gripping properties of the Parietex ProGrip mesh are not sufficient in withstanding the abdominal wall tension at the donor site after transverse rectus abdominus musculocutaneous-flap harvest and do not recommend using the Parietex ProGrip mesh without fixating sutures for this procedure.

  7. Modeling of the interaction between grip force and vibration transmissibility of a finger.

    PubMed

    Wu, John Z; Welcome, Daniel E; McDowell, Thomas W; Xu, Xueyan S; Dong, Ren G

    2017-07-01

    It is known that the vibration characteristics of the fingers and hand and the level of grip action interacts when operating a power tool. In the current study, we developed a hybrid finger model to simulate the vibrations of the hand-finger system when gripping a vibrating handle covered with soft materials. The hybrid finger model combines the characteristics of conventional finite element (FE) models, multi-body musculoskeletal models, and lumped mass models. The distal, middle, and proximal finger segments were constructed using FE models, the finger segments were connected via three flexible joint linkages (i.e., distal interphalangeal joint (DIP), proximal interphalangeal joint (PIP), and metacarpophalangeal (MCP) joint), and the MCP joint was connected to the ground and handle via lumped parameter elements. The effects of the active muscle forces were accounted for via the joint moments. The bone, nail, and hard connective tissues were assumed to be linearly elastic whereas the soft tissues, which include the skin and subcutaneous tissues, were considered as hyperelastic and viscoelastic. The general trends of the model predictions agree well with the previous experimental measurements in that the resonant frequency increased from proximal to the middle and to the distal finger segments for the same grip force, that the resonant frequency tends to increase with increasing grip force for the same finger segment, especially for the distal segment, and that the magnitude of vibration transmissibility tends to increase with increasing grip force, especially for the proximal segment. The advantage of the proposed model over the traditional vibration models is that it can predict the local vibration behavior of the finger to a tissue level, while taking into account the effects of the active musculoskeletal force, the effects of the contact conditions on vibrations, the global vibration characteristics. Published by Elsevier Ltd.

  8. Dietary Protein Intake Is Protective Against Loss of Grip Strength Among Older Adults in the Framingham Offspring Cohort

    PubMed Central

    McLean, Robert R.; Mangano, Kelsey M.; Hannan, Marian T.; Kiel, Douglas P.

    2016-01-01

    Abstract Background: Age-related decline in muscle strength is an important public health issue for older adults. Dietary protein has been associated with maintenance of muscle mass, yet its relation to muscle strength remains unclear. Methods: We determined the association of dietary protein (total, animal, and plant) intake, measured by food frequency questionnaire, with change in grip strength over 6 years in 1,746 men and women from the Framingham Offspring cohort. Results: Mean age at baseline was 58.7 years (range: 29–85), and mean total, animal, and plant protein intakes were 79, 57, and 22g/d, respectively. Adjusted baseline mean grip strength did not differ across quartiles of energy-adjusted total, animal or protein intake. Greater protein intake, regardless of source, was associated with less decrease in grip strength (all p for trend ≤.05): participants in the lowest quartiles lost 0.17% to 0.27% per year while those in the highest quartiles gained 0.52% to 0.60% per year. In analyses stratified by age, participants aged 60 years or older ( n = 646) had similar linear trends on loss of grip strength for total and animal (all p for trend <.03) but not plant protein, while the trends in participants younger than 60 years ( n = 896) were not statistically significant. Conclusions: Higher dietary intakes of total and animal protein were protective against loss of grip strength in community-dwelling adults aged 60 years and older. Increasing intake of protein from these sources may help maintain muscle strength and support prevention of mobility impairment in older adults. PMID:26525088

  9. Effects of accuracy constraints on reach-to-grasp movements in cerebellar patients.

    PubMed

    Rand, M K; Shimansky, Y; Stelmach, G E; Bracha, V; Bloedel, J R

    2000-11-01

    Reach-to-grasp movements of patients with pathology restricted to the cerebellum were compared with those of normal controls. Two types of paradigms with different accuracy constraints were used to examine whether cerebellar impairment disrupts the stereotypic relationship between arm transport and grip aperture and whether the variability of this relationship is altered when greater accuracy is required. The movements were made to either a vertical dowel or to a cross bar of a small cross. All subjects were asked to reach for either target at a fast but comfortable speed, grasp the object between the index finger and thumb, and lift it a short distance off the table. In terms of the relationship between arm transport and grip aperture, the control subjects showed a high consistency in grip aperture and wrist velocity profiles from trial to trial for movements to both the dowel and the cross. The relationship between the maximum velocity of the wrist and the time at which grip aperture was maximal during the reach was highly consistent throughout the experiment. In contrast, the time of maximum grip aperture and maximum wrist velocity of the cerebellar patients was quite variable from trial to trial, and the relationship of these measurements also varied considerably. These abnormalities were present regardless of the accuracy requirement. In addition, the cerebellar patients required a significantly longer time to grasp and lift the objects than the control subjects. Furthermore, the patients exhibited a greater grip aperture during reach than the controls. These data indicate that the cerebellum contributes substantially to the coordination of movements required to perform reach-to-grasp movements. Specifically, the cerebellum is critical for executing this behavior with a consistent, well-timed relationship between the transport and grasp components. This contribution is apparent even when accuracy demands are minimal.

  10. Metal muscles and nerves—a self-sensing SMA-actuated hand concept

    NASA Astrophysics Data System (ADS)

    Simone, F.; Rizzello, G.; Seelecke, S.

    2017-09-01

    Bio-inspired hand-like grippers actuated by Shape Memory Alloy (SMA) wires represent an emerging new technology with potential applications in many different fields, ranging from industrial assembly processes to biomedical systems. The inherently high energy density makes SMAs a natural choice for compact, lightweight, and silent actuator systems capable of producing a high amount of work, such as hand prostheses or robotic systems in industrial human/machine environments. In this work, a concept for a compact and versatile gripping system is developed, in which SMA wires are implemented as antagonistic muscles actuating an artificial hand with three fingers. In order to combine high gripping force with sufficient actuation speed, the muscle implementation pursues a multi-wire concept with several 0.1 mm diameter NiTi wires connected in parallel, in order to increase the surface-to-volume ratio for accelerated cooling. The paper starts with an illustration of the design concept of an individual 3-phalanx-finger, along with kinematic considerations for optimal placement of SMA wires. Three identical fingers are subsequently fabricated via 3D printing and assembled into a hand-like gripper. The maximum displacement of each finger phalanx is measured, and an average phalanxes dynamic responsiveness is evaluated. SMA self-sensing is documented by experiments relating the wires change in resistance to the finger motion. Several finger force measurements are also performed. The versatility of the gripper is finally documented by displaying a variety of achievable grasping configurations.

  11. Estimating thumb–index finger precision grip and manipulation potential in extant and fossil primates

    PubMed Central

    Feix, Thomas; Kivell, Tracy L.; Pouydebat, Emmanuelle; Dollar, Aaron M.

    2015-01-01

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb–index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. PMID:25878134

  12. Cortical activation during power grip task with pneumatic pressure gauge: an fMRI study

    NASA Astrophysics Data System (ADS)

    Mohamad, M.; Mardan, N. H.; Ismail, S. S.

    2017-05-01

    Aging is associated with a decline in cognitive and motor function. But, the relationships with motor performance are less well understood. In this study, functional magnetic resonance imaging (fMRI) was used to assess cortical activation in older adults. This study employed power grip task that utilised block paradigm consisted of alternate 30s rest and active. A visual cue was used to pace the hand grip movement that clenched a cylindrical rubber bulb connected with pressure pneumatic gauge that measure the pressure (Psi). The objective of this study is determined the brain areas activated during motor task and the correlation between percentage signal change of each motor area (BA 4 and 6) and hand grip pressure. Result showed there was a significant difference in mean percentage signal change in BA 4 and BA 6 in both hemispheres and negative correlation obtained in BA 4 and BA 6. These results indicate that a reduced ability in the motor networks contribute to age-related decline in motor performance.

  13. Estimating thumb-index finger precision grip and manipulation potential in extant and fossil primates.

    PubMed

    Feix, Thomas; Kivell, Tracy L; Pouydebat, Emmanuelle; Dollar, Aaron M

    2015-05-06

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb-index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  14. Effect of the Mandibular Orthopedic Repositioning Appliance (MORA) on Forearm Muscle Activation and Grasping Power during Pinch and Hook Grip.

    PubMed

    Lee, Sang-Yeol; Park, Yi-Jeong; Park, Hye-Min; Bae, Hae-Jin; Yu, Min-Ji; Choi, Hee-Won; Hwang, Na-Young

    2014-02-01

    [Purpose] This study verified the changes in muscle activities and grasping power during maximal isometric exercise of the forearm and masseter muscle with and without a mandibular orthopedic repositioning appliance (MORA). It also offers basic data for defining the correlation of function of hand with mouth. [Methods] EMG was used to measure masticatory muscle, flexor bundle and extensor bundle activities with or without MORA while subjects performed the hook grip and pinch grip. The measuring tool used for measuring grip strength was the same as that used for measuring pinch and hook strength. The subjects were 28 healthy young adults. [Result] Muscle activity and grasping power significantly increased when wearing the MORA. [Conclusion] The result indicates that wearing MORA can increase muscle activity and grasping power of forearm and masseter muscle. We think wearing MORA might help improve the function of the forearm because it activates the function of the masseter.

  15. Ergonomics and comfort in lawn mower handle positioning: An evaluation of handle geometry.

    PubMed

    Lowndes, Bethany R; Heald, Elizabeth A; Hallbeck, M Susan

    2015-11-01

    Hand operation accompanied with any combination of large forces, awkward positions and repetition may lead to upper limb injury or illness and may be exacerbated by vibration. Commercial lawn mowers expose operators to these factors during actuation of hand controls and therefore may be a health concern. A nontraditional lawn mower control system may decrease upper limb illnesses and injuries through more neutral hand and body positioning. This study compared maximum grip strength in twelve different orientations (3 grip spans and 4 positions) and evaluated self-described comfortable handle positions. The results displayed force differences between nontraditional (X) and both vertical (V) and pistol (P) positions (p < 0.0001) and among the different grip spans (p < 0.0001). Based on these results, recommended designs should incorporate a tilt between 45 and 70°, handle rotations between 48 and 78°, and reduced force requirements or decreased grip spans to improve user health and comfort. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  16. Impact of Temperature and Non-Gaussian Statistics on Electron Transfer in Donor-Bridge-Acceptor Molecules.

    PubMed

    Waskasi, Morteza M; Newton, Marshall D; Matyushov, Dmitry V

    2017-03-30

    A combination of experimental data and theoretical analysis provides evidence of a bell-shaped kinetics of electron transfer in the Arrhenius coordinates ln k vs 1/T. This kinetic law is a temperature analogue of the familiar Marcus bell-shaped dependence based on ln k vs the reaction free energy. These results were obtained for reactions of intramolecular charge shift between the donor and acceptor separated by a rigid spacer studied experimentally by Miller and co-workers. The non-Arrhenius kinetic law is a direct consequence of the solvent reorganization energy and reaction driving force changing approximately as hyperbolic functions with temperature. The reorganization energy decreases and the driving force increases when temperature is increased. The point of equality between them marks the maximum of the activationless reaction rate. Reaching the consistency between the kinetic and thermodynamic experimental data requires the non-Gaussian statistics of the donor-acceptor energy gap described by the Q-model of electron transfer. The theoretical formalism combines the vibrational envelope of quantum vibronic transitions with the Q-model describing the classical component of the Franck-Condon factor and a microscopic solvation model of the solvent reorganization energy and the reaction free energy.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waskasi, Morteza M.; Newton, Marshall D.; Matyushov, Dmitry V.

    A combination of experimental data and theoretical analysis provides evidence of a bell-shaped kinetics of electron transfer in the Arrhenius coordinates ln k vs 1/T . This kinetic law is a temperature analog of the familiar Marcus bell-shaped dependence based on ln k vs the reaction free energy. These results were obtained for reactions of intramolecular charge shift between the donor and acceptor separated by a rigid spacer studied experimentally by Miller and co-workers. The non-Arrhenius kinetic law is a direct consequence of the solvent reorganization energy and reaction driving force changing approximately as hyperbolic functions with temperature. The reorganizationmore » energy decreases and the driving force increases when temperature is increased. The point of equality between them marks the maximum of the activationless reaction rate. Reaching the consistency between the kinetic and thermodynamic experimental data requires the non-Gaussian statistics of the donor-acceptor energy gap described by the Q-model of electron transfer. Furthermore, the theoretical formalism combines the vibrational envelope of quantum vibronic transitions with the Q-model describing the classical component of the Franck-Condon factor and a microscopic solvation model of the solvent reorganization energy and the reaction free energy.« less

  18. The effects of shape crowding on grasping.

    PubMed

    Chen, Juan; Jayawardena, Sanasi; Goodale, Melvyn Alan

    2015-03-10

    Crowding refers to the deleterious effect of nearby objects on the identification of a target in the peripheral visual field. A recent study (Chen, Sperandio, & Goodale, 2015) showed that when a three-dimensional (3D) disk was crowded by disks of different sizes, participants could scale their grip aperture to the size of the target, even when they could not perceive its size. It is still unclear, however, whether or not grasping can also escape to some degree the crowding of other object features, such as shape. To test this, we presented 3D rectangular blocks in isolation or crowded by other blocks in the periphery. The target and flanking blocks had the same surface area but different dimensions. Participants were required either to grasp the target block across its width or to estimate its width. We found that, consistent with what we observed earlier with size, participants can also scale their grasp to the width of the target block even when they could not perceive its width. To further explore whether or not the effect of crowding on grasping depends on how proficient people are with their right hand, we had right-handed participants perform the same test but with their left hand. We found that left-hand grasping did not escape the crowding effect on shape perception at all. Taken together, our results suggest that people can also use invisible shape information to guide actions and that this ability depends on the proficiency of the action. © 2015 ARVO.

  19. Observing Tropical Cyclones from the Global Hawk: HAMSR Results from GRIP

    NASA Astrophysics Data System (ADS)

    Lambrigtsen, B.; Brown, S.; Behrangi, A.

    2011-12-01

    The Global Hawk unmanned aerial vehicle (UAV) recently acquired by NASA was flown for the first time in 2010 in a hurricane field campaign, the NASA Genesis and Rapid Intensification Processes (GRIP) experiment. One of the primary payloads was the High Altitude MMIC Sounding Radiometer (HAMSR) developed at the Jet Propulsion Laboratory. HAMSR is a cloud penetrating microwave sounder that provides a picture of the state of the atmosphere, such as the thermodynamic environment around hurricanes and the convective structure in the inner core. We show results from GRIP, including analysis of observations of Hurricane Karl during 13 hours during a period of rapid intensification.

  20. Trajectories and energy transfer of saltating particles onto rock surfaces : application to abrasion and ventifact formation on Earth and Mars

    NASA Technical Reports Server (NTRS)

    Bridges, Nathan T.; Phoreman, James; White, Bruce R.; Greeley, Ronald; Eddlemon, Eric E.; Wilson, Gregory R.; Meyer, Christine J.

    2005-01-01

    The interaction between saltating sand grains and rock surfaces is assessed to gauge relative abrasion potential as a function of rock shape, wind speed, grain size, and planetary environment. Many kinetic energy height profiles for impacts exhibit a distinctive increase, or kink, a few centimeters above the surface, consistent with previous field, wind tunnel, and theoretical investigations. The height of the kink observed in natural and wind tunnel settings is greater than predictions by a factor of 2 or more, probably because of enhanced bouncing off hard ground surfaces. Rebounded grains increase the effective flux and relative kinetic energy for intermediate slope angles. Whether abrasion occurs, as opposed to simple grain impact with little or no mass lost from the rock, depends on whether the grain kinetic energy (EG) exceeds a critical value (EC), as well as the flux of grains with energies above EC. The magnitude of abrasion and the shape change of the rock over time depends on this flux and the value of EG > EC. Considering the potential range of particle sizes and wind speeds, the predicted kinetic energies of saltating sand hitting rocks overlap on Earth and Mars. However, when limited to the most likely grain sizes and threshold conditions, our results agree with previous work and show that kinetic energies are about an order of magnitude greater on Mars.

  1. Prosthetic Hand For Holding Rods, Tools, And Handles

    NASA Technical Reports Server (NTRS)

    Belcher, Jewell G., Jr.; Vest, Thomas W.

    1995-01-01

    Prosthetic hand with quick-grip/quick-release lever broadens range of specialized functions available to lower-arm amputee by providing improved capabilities for gripping rods, tools, handles, and like. Includes two stationary lower fingers opposed by one pivoting upper finger. Lever operates in conjunction with attached bracket.

  2. 30 CFR 18.40 - Cable clamps and grips.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Cable clamps and grips. 18.40 Section 18.40 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design...

  3. 77 FR 32591 - Procurement List; Proposed Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-01

    ... NSN: 5120-00-NIB-0014--Shovel, Round Point, Closed Back, Industrial Grade, 48'' Fiberglass Handle, Cushioned Grip NSN: 5120-00-NIB-0015--Shovel, Round Point, Open Back, Industrial Grade, 48'' Fiberglass Handle, Cushioned Grip NSN: 5120-00-NIB-0016--Shovel, Round Point, Open Back, Industrial Grade, 29...

  4. 77 FR 44218 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-27

    ..., Fiberglass Handle NSN: 5120-00-NIB-0014--Shovel, Round Point, Closed Back, Industrial Grade, 48'' Fiberglass Handle, Cushioned Grip NSN: 5120-00-NIB-0015--Shovel, Round Point, Open Back, Industrial Grade, 48'' Fiberglass Handle, Cushioned Grip NSN: 5120-00-NIB-0016--Shovel, Round Point, Open Back, Industrial Grade, 29...

  5. Calpain-GRIP Signaling in Nucleus Accumbens Core Mediates the Reconsolidation of Drug Reward Memory.

    PubMed

    Liang, Jie; Li, Jia-Li; Han, Ying; Luo, Yi-Xiao; Xue, Yan-Xue; Zhang, Yàn; Zhang, Yán; Zhang, Li-Bo; Chen, Man-Li; Lu, Lin; Shi, Jie

    2017-09-13

    Exposure to drug-paired cues causes drug memories to be in a destabilized state and interfering with memory reconsolidation can inhibit relapse. Calpain, a calcium-dependent neutral cysteine protease, is involved in synaptic plasticity and the formation of long-term fear memory. However, the role of calpain in the reconsolidation of drug reward memory is still unknown. In the present study, using a conditioned place preference (CPP) model, we found that exposure to drug-paired contextual stimuli induced the activation of calpain and decreased the expression of glutamate receptor interacting protein 1 (GRIP1) in the nucleus accumbens (NAc) core, but not shell, of male rats. Infusions of calpain inhibitors in the NAc core immediately after retrieval disrupted the reconsolidation of cocaine/morphine cue memory and blocked retrieval-induced calpain activation and GRIP1 degradation. The suppressive effect of calpain inhibitors on the expression of drug-induced CPP lasted for at least 14 d. The inhibition of calpain without retrieval 6 h after retrieval or after exposure to an unpaired context had no effects on the expression of reward memory. Calpain inhibition after retrieval also decreased cocaine seeking in a self-administration model and this effect did not recover spontaneously after 28 d. Moreover, the knock-down of GRIP1 expression in the NAc core by lentivirus-mediated short-hairpin RNA blocked disruption of the reconsolidation of drug cue memories that was induced by calpain inhibitor treatment. These results suggest that calpain activity in the NAc core is crucial for the reconsolidation of drug reward memory via the regulation of GRIP1 expression. SIGNIFICANCE STATEMENT Calpain plays an important role in synaptic plasticity and long-term memory consolidation, however, its role in the reconsolidation of drug cue memory remains unknown. Using conditioned place preference and self-administration procedures, we found that exposure to drug-paired cues induced the activation of calpain and decreased glutamate receptor interacting protein 1 (GRIP1) expression in the nucleus accumbens (NAc) core. The inhibition of calpain activity in the NAc core immediately after retrieval disrupted the reconsolidation of cocaine/morphine cue memory that was blocked by prior GRIP1 knock-down. Our findings indicate that calpain-GRIP signaling is essential for the restabilization process that is associated with drug cue memory and the inhibition of calpain activity may be a novel strategy for the prevention of drug relapse. Copyright © 2017 the authors 0270-6474/17/378938-14$15.00/0.

  6. Long-term adherence and effects on grip strength and upper leg performance of prescribed supplemental vitamin D in pregnant and recently pregnant women of Somali and Swedish birth with 25-hydroxyvitamin D deficiency: a before-and-after treatment study.

    PubMed

    Kalliokoski, Paul; Rodhe, Nils; Bergqvist, Yngve; Löfvander, Monica

    2016-11-15

    Muscular weakness and severe vitamin D deficiency is prevalent in Somali (veiled) pregnant women, Sweden. The study aims here were to explore adherence to prescribed supplemental vitamin D in new mothers with vitamin D deficiency and its effects on grip strength and upper leg performance in Somali (target group TG) and Swedish women (reference group RG) from spring through winter. A before- and after study was designed. A cross-sectional sample of women in antenatal care with serum 25-OHD ≤50 nmol/L were prescribed one or two tablets daily (800 or 1600 IU vitamin D3 with calcium) for 10 months. Reminders were made by Somali nurses (TG) or Swedish doctors (RG). Baseline and 10 month measurements of plasma nmol/L 25-OHD, maximal grip strength held for 10 s (Newton, N) and ability to squat (yes;no) were done. Total tablet intake (n) was calculated. Outcome variables were changes from baseline in grip strength and ability to squat. Predicting variables for change in grip strength and ability to squat were calculated using linear and binary regression in final models. Undetectable 25-OHD values (<10 nmol/L) were replaced with '9' in statistic calculations. Seventy-one women (46 TG, 1/3 with undetectable baseline 25-OHD; 25 RG) participated. At the 10-month follow up, 17% TG and 8% RG women reported having refrained from supplement. Mean 25-OHD increased 16 to 49 nmol/L (TG) and 39 nmol/L to 67 nmol/L (RG), (both p < 0.001). Grip strength had improved from 153 to 188 N (TG) (p < 0.001) and from 257 to 297 N (RG) (p = 0.003) and inability to squat had decreased in TG (35 to 9, p < 0.001). Intake of number of tablets predicted increased grip strength (B 0.067, 95%CI 0.008-0.127, p = 0.027). One tablet daily (>300 in total) predicted improved ability to squat (OR 16; 95% CI 1.8-144.6). Adherence to supplemental vitamin D and calcium should be encouraged as an even moderate intake was associated to improved grip strength and upper leg performance, which was particularly useful for the women with severe 25-OHD deficiency and poor physical performance at baseline. ClinicalTrials.gov Identifier: NCT02922803 . Date of registration: September 28, 2016.

  7. Origins of cellular geometry

    PubMed Central

    2011-01-01

    Cells are highly complex and orderly machines, with defined shapes and a startling variety of internal organizations. Complex geometry is a feature of both free-living unicellular organisms and cells inside multicellular animals. Where does the geometry of a cell come from? Many of the same questions that arise in developmental biology can also be asked of cells, but in most cases we do not know the answers. How much of cellular organization is dictated by global cell polarity cues as opposed to local interactions between cellular components? Does cellular structure persist across cell generations? What is the relationship between cell geometry and tissue organization? What ensures that intracellular structures are scaled to the overall size of the cell? Cell biology is only now beginning to come to grips with these questions. PMID:21880160

  8. Body Building Boons From Apollo

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The Exer-Genie program utilizes familiar types of exercise, such as isometrics (pushing or pulling against an immovable object) and isotonics (motive exercises such as calisthenics or weight lifting) but with the important added factor of controlled resistance. The device is an arrangement of hand grips and nylon cord wrapped around an aluminum shaft. Controlled friction determines the resistance and the user can set the amount of resistive force to his own physical conditioning needs. Since Apollo days, the Exer-Genie and a similar device called the Apollo Exerciser have found wide acceptance among professional, collegiate and high school athletic teams, and among the growing number of individuals interested in physical fitness. These devices are efficient and economical replacements for conventional conditioning equipment and extremely versatile, allowing more than 100 basic exercises for shaping up specific muscle groups.

  9. D.R.O.P. The Durable Reconnaissance and Observation Platform

    NASA Technical Reports Server (NTRS)

    McKenzie, Clifford; Parness, Aaron

    2012-01-01

    The Durable Reconnaissance and Observation Platform (DROP) is a prototype robotic platform with the ability to climb concrete surfaces up to 85deg at a rate of 25cm/s, make rapid horizontal to vertical transitions, carry an audio/visual reconnaissance payload, and survive impacts from 3 meters. DROP is manufactured using a combination of selective laser sintering (SLS) and shape deposition manufacturing (SDM) techniques. The platform uses a two-wheel, two-motor design that delivers high mobility with low complexity. DROP extends microspine climbing technology from linear to rotary applications, providing improved transition ability, increased speeds, and simpler body mechanics while maintaining microspines ability to opportunistically grip rough surfaces. Various aspects of prototype design and performance are discussed, including the climbing mechanism, body design, and impact survival.

  10. Editorial: The politics of reproduction and parenting cultures - procreation, pregnancy, childbirth and childrearing.

    PubMed

    Latimer, Joanna; Thomas, Gareth M

    2017-07-01

    'Controlling life was and is to be achieved in part by rationalizing and industrializing reproductive processes. Multiple heterogeneous and contradictory groups have had an interest in achieving such control - from elites seeking to control others to individuals, especially women, trying to get a grip on their own lives through controlling their reproduction; from eugenicists ultimately trying to control evolution to neo-Malthusians trying to control national and population size; from philanthropists and foundation executives trying to shape the future of science and human life in varied directions to reproductive scientists trying to do their research … The biomedicalization of life itself (human, plant, and animal) is the key overarching and usually taken for granted social process here' (Clarke : 273-5). © 2017 Foundation for the Sociology of Health & Illness.

  11. Computer-aided diagnosis of liver tumors on computed tomography images.

    PubMed

    Chang, Chin-Chen; Chen, Hong-Hao; Chang, Yeun-Chung; Yang, Ming-Yang; Lo, Chung-Ming; Ko, Wei-Chun; Lee, Yee-Fan; Liu, Kao-Lang; Chang, Ruey-Feng

    2017-07-01

    Liver cancer is the tenth most common cancer in the USA, and its incidence has been increasing for several decades. Early detection, diagnosis, and treatment of the disease are very important. Computed tomography (CT) is one of the most common and robust imaging techniques for the detection of liver cancer. CT scanners can provide multiple-phase sequential scans of the whole liver. In this study, we proposed a computer-aided diagnosis (CAD) system to diagnose liver cancer using the features of tumors obtained from multiphase CT images. A total of 71 histologically-proven liver tumors including 49 benign and 22 malignant lesions were evaluated with the proposed CAD system to evaluate its performance. Tumors were identified by the user and then segmented using a region growing algorithm. After tumor segmentation, three kinds of features were obtained for each tumor, including texture, shape, and kinetic curve. The texture was quantified using 3 dimensional (3-D) texture data of the tumor based on the grey level co-occurrence matrix (GLCM). Compactness, margin, and an elliptic model were used to describe the 3-D shape of the tumor. The kinetic curve was established from each phase of tumor and represented as variations in density between each phase. Backward elimination was used to select the best combination of features, and binary logistic regression analysis was used to classify the tumors with leave-one-out cross validation. The accuracy and sensitivity for the texture were 71.82% and 68.18%, respectively, which were better than for the shape and kinetic curve under closed specificity. Combining all of the features achieved the highest accuracy (58/71, 81.69%), sensitivity (18/22, 81.82%), and specificity (40/49, 81.63%). The Az value of combining all features was 0.8713. Combining texture, shape, and kinetic curve features may be able to differentiate benign from malignant tumors in the liver using our proposed CAD system. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Electromyography Biofeedback Exergames to Enhance Grip Strength and Motivation.

    PubMed

    Garcia-Hernandez, Nadia; Garza-Martinez, Karen; Parra-Vega, Vicente

    2018-02-01

    Hand strength weakness affects the performance of most activities of daily living. This study aims to design, develop, and test an electromyography (EMG) biofeedback training system based on serious games to promote motivation and synchronization and proper work intensity in grip exercises for improving hand strength. An EMG surface sensor, soft balls with different stiffness and three exergames, conforms the system to drive videogame clues in response to EMG-inferred grip strength, while overseeing motivation. An experiment was designed to study the effect of performing handgrip (HG) exercises with the proposed system versus traditional exercises. Participants, organized into two groups, followed a training program for each hand. One group followed a HG exergame training (ET) with the dominant hand and traditional HG training with the nondominant hand and inverse sequence by the second group. Initial and final grip forces were measured using a digital dynamometer. Questionnaires evaluated motivation and user experience, and exercise performance was evaluated in terms of work and rest time percentage and maximal voluntary contraction percentage over contraction periods. Data were analyzed for statistically significant differences and increase of means. Participants showed significantly better exercise performance and higher grip forces, with sustained intrinsic motivation and user experience, with the ET. Improvement in force level arises evidently from the synchronized work-rest time pattern and appropriated intensity of the muscle activity. This leads to support that EMG biofeedback exergames improve motor neurons firing and resting.

  13. A Computational Model for Aperture Control in Reach-to-Grasp Movement Based on Predictive Variability

    PubMed Central

    Takemura, Naohiro; Fukui, Takao; Inui, Toshio

    2015-01-01

    In human reach-to-grasp movement, visual occlusion of a target object leads to a larger peak grip aperture compared to conditions where online vision is available. However, no previous computational and neural network models for reach-to-grasp movement explain the mechanism of this effect. We simulated the effect of online vision on the reach-to-grasp movement by proposing a computational control model based on the hypothesis that the grip aperture is controlled to compensate for both motor variability and sensory uncertainty. In this model, the aperture is formed to achieve a target aperture size that is sufficiently large to accommodate the actual target; it also includes a margin to ensure proper grasping despite sensory and motor variability. To this end, the model considers: (i) the variability of the grip aperture, which is predicted by the Kalman filter, and (ii) the uncertainty of the object size, which is affected by visual noise. Using this model, we simulated experiments in which the effect of the duration of visual occlusion was investigated. The simulation replicated the experimental result wherein the peak grip aperture increased when the target object was occluded, especially in the early phase of the movement. Both predicted motor variability and sensory uncertainty play important roles in the online visuomotor process responsible for grip aperture control. PMID:26696874

  14. An Investigation of the Mechanics and Sticking Region of a One-Repetition Maximum Close-Grip Bench Press versus the Traditional Bench Press

    PubMed Central

    Lockie, Robert G.; Callaghan, Samuel J.; Moreno, Matthew R.; Risso, Fabrice G.; Liu, Tricia M.; Stage, Alyssa A.; Birmingham-Babauta, Samantha A.; Stokes, John J.; Giuliano, Dominic V.; Lazar, Adrina; Davis, DeShaun L.; Orjalo, Ashley J.

    2017-01-01

    The close-grip bench press (CGBP) is a variation of the traditional bench press (TBP) that uses a narrower grip (~95% of biacromial distance (BAD)) and has potential application for athletes performing explosive arm actions from positions where the hands are held close to the torso. Limited research has investigated CGBP mechanics compared to the TBP. Twenty-seven resistance-trained individuals completed a one-repetition maximum TBP and CGBP. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% BAD. A linear position transducer measured lift distance and duration; peak and mean power, velocity, and force; distance and time when peak power occurred; and work. Pre-sticking region (PrSR), sticking region, and post-sticking region distance and duration for each lift was measured. A repeated measures ANOVA was used to derive differences between TBP and CGBP mechanics (p < 0.01); effect sizes (d) were also calculated. A greater load was lifted in the TBP, thus mean force was greater (d = 0.16–0.17). Peak power and velocity were higher in the CGBP, which had a longer PrSR distance (d = 0.49–1.32). The CGBP could emphasize power for athletes that initiate explosive upper-body actions with the hands positioned close to the torso.

  15. The effects of pencil grip posture and different desk designs on handwriting performance in children with hemiplegic cerebral palsy.

    PubMed

    Kavak, Sermin Tukel; Bumin, Gonca

    2009-01-01

    The aim of this study was to investigate the effect of different ergonomic desk designs and pencil grip patterns on handwriting performance in children with hemiplegic cerebral palsy and healthy children. Twenty-six children with left hemiplegic cerebral palsy and 32 typically developing children were included. The Minnesota Handwriting Assessment was used to evaluate handwriting abilities. Pencil grip posture was assessed with a 5-point rating system. Specifically designed adjustable desks and chairs were used. Four different desk types were used in this study: 1) regular desk; 2) regular desk with a 20 degrees inclination; 3) cutout desk; and 4) cutout desk with a 20 degrees inclination. Statistically significant differences were found between both groups in terms of handwriting ability (p < 0.001). There was no significant difference regarding grip scores between children with cerebral palsy and healthy children (p > 0.05). We found that children with cerebral palsy had better performance using cutout desks in relation to rate and spacing parameters of handwriting (p < 0.05). The results of our study demonstrated that the pencil grip patterns have no effect on the handwriting parameters in both children with cerebral palsy and healthy children. It is recommended that a cutout table be used to provide more upper extremity support in handwriting activities for students with cerebral palsy.

  16. Smoking impact on grip strength and fatigue resistance: implications for exercise and hand therapy practice.

    PubMed

    Al-Obaidi, Saud; Al-Sayegh, Nowall; Nadar, Mohammed

    2014-07-01

    Grip strength assessment reflects on overall health of the musculoskeletal system and is a predictor of functional prognosis and mortality. The purpose of this study was: examine whether grip-strength and fatigue resistance are impaired in smokers, determine if smoking-related impairments (fatigue-index) can be predicted by demographic data, duration of smoking, packets smoked-per-day, and physical activity. Maximum isometric grip strength (MIGS) of male smokers (n = 111) and nonsmokers (n = 66) was measured before/after induced fatigue using Jamar dynamometer at 5-handle positions. Fatigue index was calculated based on percentage change in MIGS initially and after induced fatigue. Number of repetitions to squeeze the soft rubber ball to induce fatigue was significantly lower in smokers compared with nonsmokers (t = 10.6, P < .001 dominant hand; t = 13.9, P < .001 nondominant), demonstrating a significantly higher fatigue-index for smokers than nonsmokers (t = -8.7, P < .001 dominant hand; t = -6.0, P < .001 nondominant). The effect of smoking status on MIGS scores was significantly different between smokers and nonsmokers after induced fatigue (β = -3.98, standard error = 0.59, P < .001) where smokers experienced on average a reduction of nearly 4 MIGS less than nonsmokers before fatigue. Smoking status was the strongest significant independent predictor of the fatigue-index. Smokers demonstrated reduced grip strength and fast fatigability in comparison with nonsmokers.

  17. Intercomparison of garnet barometers and implications for garnet mixing models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anovitz, L.M.; Essene, E.J.

    1985-01-01

    Several well-calibrated barometers are available in the system Ca-Fe-Ti-Al-Si-O, including: Alm+3Ru-3Ilm+Sil+2Qtz (GRAIL), 2Alm+Grreverse arrow6Ru=6Ilm+3An+3Qtz (GRIPS); 2Alm+Gr=3Fa+3An (FAG); 3AnGr+Ky+Qtz (GASP); 2Fs-Fa+Qtz (FFQ); and Gr+Qtz=An+2Wo (WAGS). GRIPS, GRAIL and GASP form a linearly dependent set such that any two should yield the third given an a/X model for the grossular/almandine solid-solution. Application to barometry of garnet granulite assemblages from the Grenville in Ontario yields average pressures 0.1 kb lower for GRIPS and 0.4 kb higher for FAGS using our mixing model. Results from Parry Island, Ontario, yield 8.7 kb from GRAIL as opposed to 9.1 kb using Ganguly and Saxena's model. Formore » GASP, Parry Island assemblages yield 8.4 kb with the authors calibration. Ganguly and Saxena's model gives 5.4 kb using Gasparik's reversals and 8.1 kb using the position of GASP calculated from GRIPS and GRAIL. These corrections allow GRIPS, GRAIL, GASP and FAGS to yield consistent pressures to +/- 0.5 kb in regional metamorphic terranes. Application of their mixing model outside of the fitted range 700-1000 K is not encouraged as extrapolation may yield erroneous results.« less

  18. Evaluation of the tooth brushing skills in children aged 6-12 years.

    PubMed

    Pujar, P; Subbareddy, V V

    2013-08-01

    To evaluate the tooth brushing skills in children aged between 6 and 12 years and its relation with age, type of grip used, duration of brushing and gender. A total of 105 children aged between 6 and 12 years were divided into seven groups and their plaque scores, type of grip used and duration of brushing were assessed. The most preferred grip was the distal oblique (58.1 %). Oblique, distal oblique and power grips were more efficient (plaque reduction up to 70 %). Plaque removal efficacy improved with age (57 % in 6-year-olds and 82 % in 12-year-old children). Plaque reduction was greater when the duration of brushing was longer (82 % plaque reduction when the brushing time was >2.5 min). Overall, the mean duration of tooth brushing in children aged 6-12 years was 1.71 min (103 s). Tooth brushing skills improved with age and the duration of tooth brushing made a significant difference to the oral hygiene status of the child. The type of grip used and gender did not influence tooth brushing ability in this group of children. Tooth brushing skills were low in children younger than 10 years of age. Hence, parental supervision is considered necessary and recommended until 10 years of age.

  19. Installation of dynamic travel time signs and efforts to obtain and test a graphical route information panel (GRIP) sign in Austin.

    DOT National Transportation Integrated Search

    2016-08-01

    Graphic Route Information Panel (GRIP) signs use a combination of text, colors, and representative maps of : the roadway system to convey real-time roadway congestion location and severity information. The intent of : this project was to facilitate t...

  20. Long-Term Performance Evaluation of Asphalt Surface Treatments: Product Placement

    DTIC Science & Technology

    2010-02-01

    20 Wheeler-Sack Army Airfield, Fort Drum , New York ...............................................................28 4...Grip Tester underside view ................................................................................ 6 Figure 3. Rotating disc of Dynamic...measures pavement friction using the braked -wheel, fixed-slip principle. Two wheels support the Grip Tester on a drive axle, while a measuring wheel with

  1. InN island shape and its dependence on growth condition of molecular-beam epitaxy

    NASA Astrophysics Data System (ADS)

    Cao, Y. G.; Xie, M. H.; Liu, Y.; Ng, Y. F.; Wu, H. S.; Tong, S. Y.

    2003-12-01

    During molecular-beam epitaxy of InN films on GaN(0001) surface, three-dimensional (3D) islands are observed following an initial wetting layer formation. Depending on deposition condition, the 3D islands take different shapes. Pyramidal islands form when excess nitrogen fluxes are used, whereas pillar-shaped islands are obtained when excess indium fluxes are employed. The pillar-shaped islands are identified to represent the equilibrium shape, whereas the pyramidal ones are limited by kinetics. As the size of islands increases, their aspect ratio shows a decreasing trend, which is attributed to a gradual relaxation of strain in the layer by defects.

  2. NMR studies of double proton transfer in hydrogen bonded cyclic N,N'-diarylformamidine dimers: conformational control, kinetic HH/HD/DD isotope effects and tunneling.

    PubMed

    Lopez, Juan Miguel; Männle, Ferdinand; Wawer, Iwona; Buntkowsky, Gerd; Limbach, Hans-Heinrich

    2007-08-28

    Using dynamic NMR spectroscopy, the kinetics of the degenerate double proton transfer in cyclic dimers of polycrystalline (15)N,(15)N'-di-(4-bromophenyl)-formamidine (DBrFA) have been studied including the kinetic HH/HD/DD isotope effects in a wide temperature range. This transfer is controlled by intermolecular interactions, which in turn are controlled by the molecular conformation and hence the molecular structure. At low temperatures, rate constants were determined by line shape analysis of (15)N NMR spectra obtained using cross-polarization (CP) and magic angle spinning (MAS). At higher temperatures, in the microsecond time scale, rate constants and kinetic isotope effects were obtained by a combination of longitudinal (15)N and (2)H relaxation measurements. (15)N CPMAS line shape analysis was also employed to study the non-degenerate double proton transfer of polycrystalline (15)N,(15)N'-diphenyl-formamidine (DPFA). The kinetic results are in excellent agreement with the kinetics of DPFA and (15)N,(15)N'-di-(4-fluorophenyl)-formamidine (DFFA) studied previously for solutions in tetrahydrofuran. Two large HH/HD and HD/DD isotope effects are observed in the whole temperature range which indicates a concerted double proton transfer mechanism in the domain of the reaction energy surface. The Arrhenius curves are non-linear indicating a tunneling mechanism. Arrhenius curve simulations were performed using the Bell-Limbach tunneling model. The role of the phenyl group conformation and hydrogen bond compression on the barrier of the proton transfer is discussed.

  3. Partitioning of a Falling Droplet's Energy After Surface Impact

    NASA Astrophysics Data System (ADS)

    Kern, Vanessa; Steen, Paul

    2017-11-01

    Understanding energy partitioning post-impact is a first step to understanding immersive flow-forming processes. Here we investigate the partitioning of kinetic energy into surface energies for capillary water droplets falling onto homogeneous prepared hydrophilic, hydrophobic and super-hydrophobic surfaces. We analyze high-speed images of the impact event. Pre-impact Weber numbers range from 0-15. After impact and initial spreading, the droplet's contact line pins. After pinning, there is a slow decay to the rest state. During this underdamped decay, the droplet's remaining kinetic energy partitions into a linear combination of mode shape energies. These mode shapes and their frequencies correspond to those of pinned sessile droplets from theory. The influence of impact energy on modes excited will be discussed.

  4. LightLeaves: computer controlled kinetic reflection hologram installation and a brief discussion of earlier work

    NASA Astrophysics Data System (ADS)

    Connors Chen, Betsy

    2013-02-01

    LightLeaves is an installation combining leaf shaped, white light reflection holograms of landscape images with a special kinetic lighting device that houses a lamp and moving leaf shaped masks. The masks are controlled by an Arduino microcontroller and servomotors that position the masks in front of the illumination source of the holograms. The work is the most recent in a long series of landscapes that combine multi-hologram installations with computer controlled devices that play with the motion of the holograms, the light, sound or other elements in the work. LightLeaves was first exhibited at the Peabody Essex Museum in Salem, Massachusetts in a show titled "Eye Spy: Playing with Perception".

  5. GRiP - A flexible approach for calculating risk as a function of consequence, vulnerability, and threat.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitfield, R. G.; Buehring, W. A.; Bassett, G. W.

    2011-04-08

    Get a GRiP (Gravitational Risk Procedure) on risk by using an approach inspired by the physics of gravitational forces between body masses! In April 2010, U.S. Department of Homeland Security Special Events staff (Protective Security Advisors [PSAs]) expressed concern about how to calculate risk given measures of consequence, vulnerability, and threat. The PSAs believed that it is not 'right' to assign zero risk, as a multiplicative formula would imply, to cases in which the threat is reported to be extremely small, and perhaps could even be assigned a value of zero, but for which consequences and vulnerability are potentially high.more » They needed a different way to aggregate the components into an overall measure of risk. To address these concerns, GRiP was proposed and developed. The inspiration for GRiP is Sir Isaac Newton's Universal Law of Gravitation: the attractive force between two bodies is directly proportional to the product of their masses and inversely proportional to the squares of the distance between them. The total force on one body is the sum of the forces from 'other bodies' that influence that body. In the case of risk, the 'other bodies' are the components of risk (R): consequence, vulnerability, and threat (which we denote as C, V, and T, respectively). GRiP treats risk as if it were a body within a cube. Each vertex (corner) of the cube represents one of the eight combinations of minimum and maximum 'values' for consequence, vulnerability, and threat. The risk at each of the vertices is a variable that can be set. Naturally, maximum risk occurs when consequence, vulnerability, and threat are at their maximum values; minimum risk occurs when they are at their minimum values. Analogous to gravitational forces among body masses, the GRiP formula for risk states that the risk at any interior point of the box depends on the squares of the distances from that point to each of the eight vertices. The risk value at an interior (movable) point will be dominated by the value of one vertex as that point moves closer and closer to that one vertex. GRiP is a visualization tool that helps analysts better understand risk and its relationship to consequence, vulnerability, and threat. Estimates of consequence, vulnerability, and threat are external to GRiP; however, the GRiP approach can be linked to models or data that provide estimates of consequence, vulnerability, and threat. For example, the Enhanced Critical Infrastructure Program/Infrastructure Survey Tool produces a vulnerability index (scaled from 0 to 100) that can be used for the vulnerability component of GRiP. We recognize that the values used for risk components can be point estimates and that, in fact, there is uncertainty regarding the exact values of C, V, and T. When we use T = t{sub o} (where t{sub o} is a value of threat in its range), we mean that threat is believed to be in an interval around t{sub o}. Hence, a value of t{sub o} = 0 indicates a 'best estimate' that the threat level is equal to zero, but still allows that it is not impossible for the threat to occur. When t{sub o} = 0 but is potentially small and not exactly zero, there will be little impact on the overall risk value as long as the C and V components are not large. However, when C and/or V have large values, there can be large differences in risk given t{sub o} = 0, and t{sub o} = epsilon (where epsilon is small but greater than a value of zero). We believe this scenario explains the PSA's intuition that risk is not equal to zero when t{sub o} = 0 and C and/or V have large values. (They may also be thinking that if C has an extremely large value, it is unlikely that T is equal to 0; in the terrorist context, T would likely be dependent on C when C is extremely large.) The PSAs are implicitly recognizing the potential that t{sub o} = epsilon. One way to take this possible scenario into account is to replace point estimates for risk with interval values that reflect the uncertainty in the risk components. In fact, one could argue that T never equals zero for a man-made hazard. This paper describes the thought process that led to the GRiP approach and the mathematical formula for GRiP and presents a few examples that will provide insights about how to use GRiP and interpret its results.« less

  6. Exploring the Roles of Nucleobase Desolvation and Shape Complementarity during the Misreplication of O6-Methylguanine

    PubMed Central

    Chavarria, Delia; Ramos-Serrano, Andrea; Hirao, Ichiro; Berdis, Anthony J.

    2011-01-01

    O6-methylguanine is a miscoding DNA lesion arising from the alkylation of guanine. This report uses the bacteriophage T4 DNA polymerase as a model to probe the roles hydrogen-bonding interactions, shape/size, and nucleobase desolvation during the replication of this miscoding lesion. This was accomplished by using transient kinetic techniques to monitor the kinetic parameters for incorporating and extending natural and non-natural nucleotides. In general, the efficiency of nucleotide incorporation does not depend on the hydrogen-bonding potential of the incoming nucleotide. Instead, nucleobase hydrophobicity and shape complementarity appear to be the preeminent factors controlling nucleotide incorporation. In addition, shape complementarity plays a large role in controlling the extension of various mispairs containing O6-methylguanine. This is evident as the rate constants for extension correlate with proper interglycosyl distances and symmetry between the base angles of the formed mispair. Base pairs not conforming to an acceptable geometry within the polymerase’s active site are refractory to elongation and are processed via exonuclease proofreading. The collective data set encompassing nucleotide incorporation, extension, and excision is used to generate a model accounting for the mutagenic potential of O6-methylguanine observed in vivo. In addition, kinetic studies monitoring the incorporation and extension of non-natural nucleotides identified an analog that displays high selectivity for incorporation opposite O6-methylguanine compared to unmodified purines. The unusual selectivity of this analog for replicating damaged DNA provides a novel biochemical tool to study translesion DNA synthesis. PMID:21819995

  7. [INVITED] Control of femtosecond pulsed laser ablation and deposition by temporal pulse shaping

    NASA Astrophysics Data System (ADS)

    Garrelie, Florence; Bourquard, Florent; Loir, Anne--Sophie; Donnet, Christophe; Colombier, Jean-Philippe

    2016-04-01

    This study explores the effects of temporal laser pulse shaping on femtosecond pulsed laser deposition (PLD). The potential of laser pulses temporally tailored on ultrafast time scales is used to control the expansion and the excitation degree of ablation products including atomic species and nanoparticles. The ablation plume generated by temporally shaped femtosecond pulsed laser ablation of aluminum and graphite targets is studied by in situ optical diagnostic methods. Taking advantage of automated pulse shaping techniques, an adaptive procedure based on spectroscopic feedback regulates the irradiance for the enhancement of typical plasma features. Thin films elaborated by unshaped femtosecond laser pulses and by optimized sequence indicate that the nanoparticles generation efficiency is strongly influenced by the temporal shaping of the laser irradiation. The ablation processes leading either to the generation of the nanoparticles either to the formation of plasma can be favored by using a temporal shaping of the laser pulse. Insights are given on the possibility to control the quantity of the nanoparticles. The temporal laser pulse shaping is shown also to strongly modify the laser-induced plasma contents and kinetics for graphite ablation. Temporal pulse shaping proves its capability to reduce the number of slow radicals while increasing the proportion of monomers, with the addition of ionized species in front of the plume. This modification of the composition and kinetics of plumes in graphite ablation using temporal laser pulse shaping is discussed in terms of modification of the structural properties of deposited Diamond-Like Carbon films (DLC). This gives rise to a better understanding of the growth processes involved in femtosecond-PLD and picosecond-PLD of DLC suggesting the importance of neutral C atoms, which are responsible for the subplantation process.

  8. Concentric wrench for blind access opening in a turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurer, Kurt Neal; Drlik, Gary Joseph; Gibler, Edward Eugene

    The concentric wrench includes an outer tube having flats at one end and a gripping surface at an opposite end. An inner tube has interior flats at one end and a gripping surface at its opposite end. With the inner and outer tubes disposed about a pressure transmitting conduit, the tubes may be inserted into a blind access opening in the outer turbine casing to engage the flats of the tubes against hex nuts of an internal fitting. By relatively rotating the tubes using the externally exposed gripping surfaces, the threaded connection between the parts of the fitting bearing themore » respective hex nuts can be tightened or loosened.« less

  9. Airborne Wind Profiling With the Data Acquisition and Processing System for a Pulsed 2-Micron Coherent Doppler Lidar System

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y.; Koch, Grady J.; Kavaya, Michael J.

    2012-01-01

    A pulsed 2-micron coherent Doppler lidar system at NASA Langley Research Center in Virginia flew on the NASA's DC-8 aircraft during the NASA Genesis and Rapid Intensification Processes (GRIP) during the summer of 2010. The participation was part of the project Doppler Aerosol Wind Lidar (DAWN) Air. Selected results of airborne wind profiling are presented and compared with the dropsonde data for verification purposes. Panoramic presentations of different wind parameters over a nominal observation time span are also presented for selected GRIP data sets. The realtime data acquisition and analysis software that was employed during the GRIP campaign is introduced with its unique features.

  10. Get a Grip! A Middle School Engineering Challenge

    ERIC Educational Resources Information Center

    Olds, Suzanne A.; Harrell, Deborah A.; Valente, Michael E.

    2006-01-01

    Investigating the field of engineering offers the opportunity for interdisciplinary, hands-on, inquiry-based units that integrate real-world applications. However, many K-12 students are not exposed to engineering until they enter college. Get a Grip! is a problem-based unit that places middle school students in the role of engineers who are…

  11. Flash Detection Efficiencies of Long Range Lightning Detection Networks During GRIP

    NASA Technical Reports Server (NTRS)

    Mach, Douglas M.; Bateman, Monte G.; Blakeslee, Richard J.

    2012-01-01

    We flew our Lightning Instrument Package (LIP) on the NASA Global Hawk as a part of the Genesis and Rapid Intensification Processes (GRIP) field program. The GRIP program was a NASA Earth science field experiment during the months of August and September, 2010. During the program, the LIP detected lighting from 48 of the 213 of the storms overflown by the Global Hawk. The time and location of tagged LIP flashes can be used as a "ground truth" dataset for checking the detection efficiency of the various long or extended range ground-based lightning detection systems available during the GRIP program. The systems analyzed included Vaisala Long Range (LR), Vaisala GLD360, the World Wide Lightning Location Network (WWLLN), and the Earth Networks Total Lightning Network (ENTLN). The long term goal of our research is to help understand the advantages and limitations of these systems so that we can utilize them for both proxy data applications and cross sensor validation of the GOES-R Geostationary Lightning Mapper (GLM) sensor when it is launched in the 2015 timeframe.

  12. Heuristic control of the Utah/MIT dextrous robot hand

    NASA Technical Reports Server (NTRS)

    Bass, Andrew H., Jr.

    1987-01-01

    Basic hand grips and sensor interactions that a dextrous robot hand will need as part of the operation of an EVA Retriever are analyzed. What is to be done with a dextrous robot hand is examined along with how such a complex machine might be controlled. It was assumed throughout that an anthropomorphic robot hand should perform tasks just as a human would; i.e., the most efficient approach to developing control strategies for the hand would be to model actual hand actions and do the same tasks in the same ways. Therefore, basic hand grips that human hands perform, as well as hand grip action were analyzed. It was also important to examine what is termed sensor fusion. This is the integration of various disparate sensor feedback paths. These feedback paths can be spatially and temporally separated, as well as, of different sensor types. Neural networks are seen as a means of integrating these varied sensor inputs and types. Basic heuristics of hand actions and grips were developed. These heuristics offer promise of control dextrous robot hands in a more natural and efficient way.

  13. Grip and slip of L1-CAM on adhesive substrates direct growth cone haptotaxis

    PubMed Central

    Abe, Kouki; Katsuno, Hiroko; Toriyama, Michinori; Baba, Kentarou; Mori, Tomoyuki; Hakoshima, Toshio; Kanemura, Yonehiro; Watanabe, Rikiya; Inagaki, Naoyuki

    2018-01-01

    Chemical cues presented on the adhesive substrate direct cell migration, a process termed haptotaxis. To migrate, cells must generate traction forces upon the substrate. However, how cells probe substrate-bound cues and generate directional forces for migration remains unclear. Here, we show that the cell adhesion molecule (CAM) L1-CAM is involved in laminin-induced haptotaxis of axonal growth cones. L1-CAM underwent grip and slip on the substrate. The ratio of the grip state was higher on laminin than on the control substrate polylysine; this was accompanied by an increase in the traction force upon laminin. Our data suggest that the directional force for laminin-induced growth cone haptotaxis is generated by the grip and slip of L1-CAM on the substrates, which occur asymmetrically under the growth cone. This mechanism is distinct from the conventional cell signaling models for directional cell migration. We further show that this mechanism is disrupted in a human patient with L1-CAM syndrome, suffering corpus callosum agenesis and corticospinal tract hypoplasia. PMID:29483251

  14. Investigation of index finger triggering force using a cadaver experiment: Effects of trigger grip span, contact location, and internal tendon force.

    PubMed

    Chang, Joonho; Freivalds, Andris; Sharkey, Neil A; Kong, Yong-Ku; Mike Kim, H; Sung, Kiseok; Kim, Dae-Min; Jung, Kihyo

    2017-11-01

    A cadaver study was conducted to investigate the effects of triggering conditions (trigger grip span, contact location, and internal tendon force) on index finger triggering force and the force efficiency of involved tendons. Eight right human cadaveric hands were employed, and a motion simulator was built to secure and control the specimens. Index finger triggering forces were investigated as a function of different internal tendon forces (flexor digitorum profundus + flexor digitorum superficialis = 40, 70, and 100 N), trigger grip spans (40, 50, and 60 mm), and contact locations between the index finger and a trigger. Triggering forces significantly increased when internal tendon forces increased from 40 to 100 N. Also, trigger grip spans and contact locations had significant effects on triggering forces; maximum triggering forces were found at a 50 mm span and the most proximal contact location. The results revealed that only 10-30% of internal tendon forces were converted to their external triggering forces. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The end-state comfort effect in bimanual grip selection.

    PubMed

    Fischman, Mark G; Stodden, David F; Lehman, Davana M

    2003-03-01

    During a unimanual grip selection task in which people pick up a lightweight dowel and place one end against targets at variable heights, the choice of hand grip (overhand vs. underhand) typically depends on the perception of how comfortable the arm will be at the end of the movement: an end-state comfort effect. The two experiments reported here extend this work to bimanual tasks. In each experiment, 26 right-handed participants used their left and right hands to simultaneously pick up two wooden dowels and place either the right or left end against a series of 14 targets ranging from 14 to 210 cm above the floor. These tasks were performed in systematic ascending and descending orders in Experiment 1 and in random order in Expiment 2. Results were generally consistent with predictions of end-state comfort in that, for the extreme highest and lowest targets, participants tended to select opposite grips with each hand. Taken together, our findings are consistent with the concept of constraint hierarchies within a posture-based motion-planning model.

  16. NASA's Genesis and Rapid Intensification Processes (GRIP) Field Experiment

    NASA Technical Reports Server (NTRS)

    Braun, Scott A.; Kakar, Ramesh; Zipser, Edward; Heymsfield, Gerald; Albers, Cerese; Brown, Shannon; Durden, Stephen; Guimond, Stephen; Halverson, Jeffery; Heymsfield, Andrew; hide

    2013-01-01

    In August–September 2010, NASA, NOAA, and the National Science Foundation (NSF) conducted separate but closely coordinated hurricane field campaigns, bringing to bear a combined seven aircraft with both new and mature observing technologies. NASA's Genesis and Rapid Intensification Processes (GRIP) experiment, the subject of this article, along with NOAA's Intensity Forecasting Experiment (IFEX) and NSF's Pre-Depression Investigation of Cloud-Systems in the Tropics (PREDICT) experiment, obtained unprecedented observations of the formation and intensification of tropical cyclones. The major goal of GRIP was to better understand the physical processes that control hurricane formation and intensity change, specifically the relative roles of environmental and inner-core processes. A key focus of GRIP was the application of new technologies to address this important scientific goal, including the first ever use of the unmanned Global Hawk aircraft for hurricane science operations. NASA and NOAA conducted coordinated flights to thoroughly sample the rapid intensification (RI) of Hurricanes Earl and Karl. The tri-agency aircraft teamed up to perform coordinated flights for the genesis of Hurricane Karl and Tropical Storm Matthew and the non-redevelopment of the remnants of Tropical Storm Gaston. The combined GRIP–IFEX–PREDICT datasets, along with remote sensing data from a variety of satellite platforms [Geostationary Operational Environmental Satellite (GOES), Tropical Rainfall Measuring Mission (TRMM), Aqua, Terra, CloudSat, and Cloud–Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO)], will contribute to advancing understanding of hurricane formation and intensification. This article summarizes the GRIP experiment, the missions flown, and some preliminary findings.

  17. E-cadherin transport from the trans-Golgi network in tubulovesicular carriers is selectively regulated by golgin-97.

    PubMed

    Lock, John G; Hammond, Luke A; Houghton, Fiona; Gleeson, Paul A; Stow, Jennifer L

    2005-12-01

    E-cadherin is a cell-cell adhesion protein that is trafficked and delivered to the basolateral cell surface. Membrane-bound carriers for the post-Golgi exocytosis of E-cadherin have not been characterized. Green fluorescent protein (GFP)-tagged E-cadherin (Ecad-GFP) is transported from the trans-Golgi network (TGN) to the recycling endosome on its way to the cell surface in tubulovesicular carriers that resemble TGN tubules labeled by members of the golgin family of tethering proteins. Here, we examine the association of golgins with tubular carriers containing E-cadherin as cargo. Fluorescent GRIP domains from golgin proteins replicate the membrane binding of the full-length proteins and were coexpressed with Ecad-GFP. The GRIP domains of p230/golgin-245 and golgin-97 had overlapping but nonidentical distributions on the TGN; both domains were on TGN-derived tubules but only the golgin-97 GRIP domain coincided with Ecad-GFP tubules in live cells. When the Arl1-binding endogenous golgins, p230/golgin-245 and golgin-97 were displaced from Golgi membranes by overexpression of the p230 GRIP domain, trafficking of Ecad-GFP was inhibited. siRNA knockdown of golgin-97 also inhibited trafficking of Ecad-GFP. Thus, the GRIP domains of p230/golgin-245 and golgin-97 bind discriminately to distinct membrane subdomains of the TGN. Golgin-97 is identified as a selective and essential component of the tubulovesicular carriers transporting E-cadherin out of the TGN.

  18. 78 FR 38483 - Area Risk Protection Insurance Regulations and Area Risk Protection Insurance Crop Provisions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-26

    ...The Federal Crop Insurance Corporation (FCIC) finalizes the Area Risk Protection Insurance (ARPI) Basic Provisions, ARPI Barley Crop Insurance Provisions, ARPI Corn Crop Insurance Provisions, ARPI Cotton Crop Insurance Provisions, ARPI Forage Crop Insurance Provisions, ARPI Grain Sorghum Crop Insurance Provisions, ARPI Peanut Crop Insurance Provisions, ARPI Soybean Crop Insurance Provisions, and ARPI Wheat Crop Insurance Provisions to provide area yield protection and area revenue protection. These provisions will replace the Group Risk Plan (GRP) provisions in 7 CFR part 407, which includes the: GRP Basic Provisions, GRP Barley Crop Provisions, GRP Corn Crop Provisions, GRP Cotton Crop Provisions, GRP Forage Crop Provisions, GRP Peanut Crop Provisions, GRP Sorghum Crop Provisions, GRP Soybean Crop Provisions, and GRP Wheat Crop Provisions. The ARPI provisions will also replace the Group Risk Income Protection (GRIP) Basic Provisions, the GRIP Crop Provisions, and the GRIP-Harvest Revenue Option (GRIP-HRO). The GRP and GRIP plans of insurance will no longer be available. The intended effect of this action is to offer producers a choice of Area Revenue Protection, Area Revenue Protection with the Harvest Price Exclusion, or Area Yield Protection, all within one Basic Provision and the applicable Crop Provisions. This will reduce the amount of information producers must read to determine the best risk management tool for their operation and will improve the provisions to better meet the needs of insureds. The changes will apply for the 2014 and succeeding crop years.

  19. [Reliability and validity of the analysis of hand grip and pinch force in isometric and isokinetic conditions].

    PubMed

    Benaglia, P G; Franchignoni, F; Ferriero, G; Zebellin, G; Sartorio, F

    1999-01-01

    Strength measurement of the hand grip is at the core of most protocols of functional assessment of the upper limb and in rehabilitation plays a major role in the analysis of treatment efficacy and patients' occupational ability. The aims of this study were to: a) verify the repeatability of strength measurements made during performance of the hand grip and three types of pinch, carried out under isometric and isokinetic conditions; b) compare maximal isometric strength with the corresponding isokinetic value for each of the manoeuvres studied; c) investigate the correlations between the strength expressed in the different manoeuvres, under both isometric and isokinetic conditions. We studied 14 voluntary subjects over three sessions conducted at 48-hr intervals, employing a computerized isokinetic dynamometer Lido WorkSet equipped with device N(o) 21 for the study of pinch (lateral pinch, pulp pinch, chuck pinch) and device N(o) 52 for the grip study. Isometric contractions resulted stronger than isokinetic ones, and the hand grip was found to be the manoeuvre able to produce most strength. The repeatability of each strength measurement test over the three days was high (Intraclass Correlation Coefficients: 0.89-0.93). Correlations between the isometric and isokinetic performance for each of the manoeuvres examined were always high (Pearson's r coefficients: 0.89-0.95) as were those between the different manoeuvres, whether performed in isometric or isokinetic modality (r: 0.60-0.94).

  20. The Effect of Isometric Massage on Global Grip Strength after Conservative Treatment of Distal Radial Fractures. Pilot Study.

    PubMed

    Ratajczak, Karina; Płomiński, Janusz

    2015-01-01

    The most common fracture of the distal end of the radius is Colles' fracture. Treatment modalities available for use in hand rehabilitation after injury include massage. The aim of this study was to evaluate the effect of isometric massage on the recovery of hand function in patients with Colles fractures. For this purpose, the strength of the finger flexors was assessed as an objective criterion for the evaluation of hand function. The study involved 40 patients, randomly divided into Group A of 20 patients and Group B of 20 patients. All patients received physical therapy and exercised individually with a physiotherapist. Isometric massage was additionally used in Group A. Global grip strength was assessed using a pneumatic force meter on the first and last day of therapy. Statistical analysis was performed using STATISTICA. Statistical significance was defined as a P value of less than 0.05. In both groups, global grip strength increased significantly after the therapy. There was no statistically significant difference between the groups. The men and women in both groups equally improved grip strength. A statistically significant difference was demonstrated between younger and older patients, with younger patients achieving greater gains in global grip strength in both groups. The incorporation of isometric massage in the rehabilitation plan of patients after a distal radial fracture did not significantly contribute to faster recovery of hand function or improve their quality of life.

  1. Effects of the forearm support band on wrist extensor muscle fatigue.

    PubMed

    Knebel, P T; Avery, D W; Gebhardt, T L; Koppenhaver, S L; Allison, S C; Bryan, J M; Kelly, A

    1999-11-01

    A crossover experimental design with repeated measures. To determine whether the forearm support band alters wrist extensor muscle fatigue. Fatigue of the wrist extensor muscles is thought to be a contributing factor in the development of lateral epicondylitis. The forearm support band is purported to reduce or prevent symptoms of lateral epicondylitis but the mechanism of action is unknown. Fifty unimpaired subjects (36 men, 14 women; mean age = 29 +/- 6 years) were tested with and without a forearm support band before and after a fatiguing bout of exercise. Peak wrist extension isometric force, peak isometric grip force, and median power spectral frequency for wrist extensor electromyographic activity were measured before and after exercise and with and without the forearm support band. A 2 x 2 repeated measures multivariate analysis of variance was used to analyze the data, followed by univariate analysis of variance and Tukey's multiple comparison tests. Peak wrist extension isometric force, peak grip isometric force, and median power spectral frequency were all reduced after exercise. However, there was a significant reduction in peak grip isometric force and peak wrist extension isometric force values for the with-forearm support band condition (grip force 28%, wrist extension force 26%) compared to the without-forearm support band condition (grip force 18%, wrist extension force 15%). Wearing the forearm support band increased the rate of fatigue in unimpaired individuals. Our findings do not support the premise that wearing the forearm support band reduces muscle fatigue in the wrist extensors.

  2. Physical function, grip strength and frailty in people living with HIV in sub-Saharan Africa: systematic review.

    PubMed

    Bernard, Charlotte; Dabis, François; de Rekeneire, Nathalie

    2017-05-01

    To present the current knowledge on physical function, grip strength and frailty in HIV-infected patients living in sub-Saharan Africa, where the phenomenon is largely underestimated. A systematic search was conducted on MEDLINE, Scopus and African Index Medicus. We reviewed articles on sub-Saharan African people living with HIV (PLHIV) >18 years old, published until November 2016. Of 537 articles, 12 were conducted in six African countries and included in this review. Five articles reported information on functional limitation and one on disability. Two of these five articles reported functional limitation (low gait speed) in PLHIV. Disability was observed in 27% and 3% of PLHIV living in rural and urban places, respectively. Two of three studies reporting grip strength reported lower grip strength (nearly 4 kg) in PLHIV in comparison with uninfected patients. One study reported that PLHIV were more likely to be frail than HIV-uninfected individuals (19.4% vs. 13.3%), whereas another reported no statistical difference. Decline in physical function, grip strength and frailty are now part of the burden of PLHIV living in SSA countries, but current data are insufficient to characterise the real public health dimension of these impairments. Further studies are needed to depict this major public health challenge. As this is likely to contribute to a significant burden on the African healthcare systems and human resources in the near future, a holistic care approach should be developed to inform guidelines. © 2017 John Wiley & Sons Ltd.

  3. Using goal- and grip-related information for understanding the correctness of other's actions: an ERP study.

    PubMed

    van Elk, Michiel; Bousardt, Roel; Bekkering, Harold; van Schie, Hein T

    2012-01-01

    Detecting errors in other's actions is of pivotal importance for joint action, competitive behavior and observational learning. Although many studies have focused on the neural mechanisms involved in detecting low-level errors, relatively little is known about error-detection in everyday situations. The present study aimed to identify the functional and neural mechanisms whereby we understand the correctness of other's actions involving well-known objects (e.g. pouring coffee in a cup). Participants observed action sequences in which the correctness of the object grasped and the grip applied to a pair of objects were independently manipulated. Observation of object violations (e.g. grasping the empty cup instead of the coffee pot) resulted in a stronger P3-effect than observation of grip errors (e.g. grasping the coffee pot at the upper part instead of the handle), likely reflecting a reorienting response, directing attention to the relevant location. Following the P3-effect, a parietal slow wave positivity was observed that persisted for grip-errors, likely reflecting the detection of an incorrect hand-object interaction. These findings provide new insight in the functional significance of the neurophysiological markers associated with the observation of incorrect actions and suggest that the P3-effect and the subsequent parietal slow wave positivity may reflect the detection of errors at different levels in the action hierarchy. Thereby this study elucidates the cognitive processes that support the detection of action violations in the selection of objects and grips.

  4. Measuring the Speed of Aging across Population Subgroups

    PubMed Central

    2014-01-01

    People in different subgroups age at different rates. Surveys containing biomarkers can be used to assess these subgroup differences. We illustrate this using hand-grip strength to produce an easily interpretable, physical-based measure that allows us to compare characteristic-based ages across educational subgroups in the United States. Hand-grip strength has been shown to be a good predictor of future mortality and morbidity, and therefore a useful indicator of population aging. Data from the Health and Retirement Survey (HRS) were used. Two education subgroups were distinguished, those with less than a high school diploma and those with more education. Regressions on hand-grip strength were run for each sex and race using age and education, their interactions and other covariates as independent variables. Ages of identical mean hand-grip strength across education groups were compared for people in the age range 60 to 80. The hand-grip strength of 65 year old white males with less education was the equivalent to that of 69.6 (68.2, 70.9) year old white men with more education, indicating that the more educated men had aged more slowly. This is a constant characteristic age, as defined in the Sanderson and Scherbov article “The characteristics approach to the measurement of population aging” published 2013 in Population and Development Review. Sixty-five year old white females with less education had the same average hand-grip strength as 69.4 (68.2, 70.7) year old white women with more education. African-American women at ages 60 and 65 with more education also aged more slowly than their less educated counterparts. African American men with more education aged at about the same rate as those with less education. This paper expands the toolkit of those interested in population aging by showing how survey data can be used to measure the differential extent of aging across subpopulations. PMID:24806337

  5. The association between physical activity and risk of mortality is modulated by grip strength and cardiorespiratory fitness: evidence from 498 135 UK-Biobank participants

    PubMed Central

    Celis-Morales, Carlos A.; Lyall, Donald M.; Anderson, Jana; Iliodromiti, Stamatina; Fan, Yu; Ntuk, Uduakobong E.; Mackay, Daniel F.; Pell, Jill P.; Sattar, Naveed; Gill, Jason M.R.

    2017-01-01

    Aims It is unclear whether the potential benefits of physical activity differ according to level of cardiorespiratory fitness (CRF) or strength. The aim of this study was to determine whether the association between physical activity and mortality is moderated by CRF and grip strength sufficiently to inform health promotion strategies. Methods and results 498 135 participants (54.7% women) from the UK Biobank were included (CRF data available in 67 702 participants). Exposure variables were grip strength, CRF, and physical activity. All-cause mortality and cardiovascular disease (CVD) events were the outcomes. 8591 died over median 4.9 years [IQR 4.3–5.5] follow-up. There was a significant interaction between total physical activity and grip strength (P < 0.0001) whereby the higher hazard of mortality associated with lower physical activity was greatest among participants in the lowest tertile for grip strength (hazard ratio, HR:1.11 [95% CI 1.09–1.14]) and lowest among those in the highest grip strength tertile (HR:1.04 [1.01–1.08]). The interaction with CRF did not reach statistical significance but the pattern was similar. The association between physical activity and mortality was larger among those in the lowest tertile of CRF (HR:1.13 [1.02–1.26]) than those in the highest (HR:1.03 [0.91–1.16]). The pattern for CVD events was similar. Conclusions These data provide novel evidence that strength, and possibly CRF, moderate the association between physical activity and mortality. The association between physical activity and mortality is strongest in those with the lowest strength (which is easily measured), and the lowest CRF, suggesting that these sub-groups could benefit most from interventions to increase physical activity. PMID:28158566

  6. Hand grip strength and maximum peak expiratory flow: determinants of bone mineral density of adolescent students.

    PubMed

    Cossio-Bolaños, Marco; Lee-Andruske, Cynthia; de Arruda, Miguel; Luarte-Rocha, Cristian; Almonacid-Fierro, Alejandro; Gómez-Campos, Rossana

    2018-03-02

    Maintaining and building healthy bones during the lifetime requires a complicated interaction between a number of physiological and lifestyle factors. Our goal of this study was to analyze the association between hand grip strength and the maximum peak expiratory flow with bone mineral density and content in adolescent students. The research team studied 1427 adolescent students of both sexes (750 males and 677 females) between the ages of 11.0 and 18.9 years in the Maule Region of Talca (Chile). Weight, standing height, sitting height, hand grip strength (HGS), and maximum peak expiratory flow (PEF) were measured. Furthermore, bone mineral density (BMD) and total body bone mineral content (BMC) were determined by using the Dual-Energy X-Ray Absorptiometry (DXA). Hand grip strength and PEF were categorized in tertiles (lowest, middle, and highest). Linear regression was performed in steps to analyze the relationship between the variables. Differences between categories were determined through ANOVA. In males, the hand grip strength explained 18-19% of the BMD and 20-23% of the BMC. For the females, the percentage of variation occurred between 12 and 13% of the BMD and 17-18% of the BMC. The variation of PEF for the males was observed as 33% of the BMD and 36% of the BMC. For the females, both the BMD and BMC showed a variation of 19%. The HGS and PEF were divided into three categories (lowest, middle, and highest). In both cases, significant differences occurred in bone density health between the three categories. In conclusion, the HGS and the PEF related positively to the bone density health of both sexes of adolescent students. The adolescents with poor values for hand grip strength and expiratory flow showed reduced values of BMD and BMC for the total body. Furthermore, the PEF had a greater influence on bone density health with respect to the HGS of the adolescents of both sexes.

  7. Coordination of precision grip in 2–6 years-old children with autism spectrum disorders compared to children developing typically and children with developmental disabilities

    PubMed Central

    David, Fabian J.; Baranek, Grace T.; Wiesen, Chris; Miao, Adrienne F.; Thorpe, Deborah E.

    2012-01-01

    Impaired motor coordination is prevalent in children with Autism Spectrum Disorders (ASD) and affects adaptive skills. Little is known about the development of motor patterns in young children with ASD between 2 and 6 years of age. The purpose of the current study was threefold: (1) to describe developmental correlates of motor coordination in children with ASD, (2) to identify the extent to which motor coordination deficits are unique to ASD by using a control group of children with other developmental disabilities (DD), and (3) to determine the association between motor coordination variables and functional fine motor skills. Twenty-four children with ASD were compared to 30 children with typical development (TD) and 11 children with DD. A precision grip task was used to quantify and analyze motor coordination. The motor coordination variables were two temporal variables (grip to load force onset latency and time to peak grip force) and two force variables (grip force at onset of load force and peak grip force). Functional motor skills were assessed using the Fine Motor Age Equivalents of the Vineland Adaptive Behavior Scale and the Mullen Scales of Early Learning. Mixed regression models were used for all analyses. Children with ASD presented with significant motor coordination deficits only on the two temporal variables, and these variables differentiated children with ASD from the children with TD, but not from children with DD. Fine motor functional skills had no statistically significant associations with any of the motor coordination variables. These findings suggest that subtle problems in the timing of motor actions, possibly related to maturational delays in anticipatory feed-forward mechanisms, may underlie some motor deficits reported in children with ASD, but that these issues are not unique to this population. Further research is needed to investigate how children with ASD or DD compensate for motor control deficits to establish functional skills. PMID:23293589

  8. Bilateral deficits in fine motor control and pinch grip force are not associated with electrodiagnostic findings in women with carpal tunnel syndrome.

    PubMed

    de la Llave-Rincón, Ana Isabel; Fernández-de-Las-Peñas, César; Pérez-de-Heredia-Torres, Marta; Martínez-Perez, Almudena; Valenza, Marie Carmen; Pareja, Juan A

    2011-06-01

    : The aim of this study was to analyze the differences in deficits in fine motor control and pinch grip force between patients with minimal, moderate/mild, or severe carpal tunnel syndrome (CTS) and healthy age- and hand dominance-matched controls. : A case-control study was conducted. The subtests of the Purdue Pegboard Test (one-hand and bilateral pin placements and assemblies) and pinch grip force between the thumb and the remaining four fingers of the hand were bilaterally evaluated in 66 women with minimal (n = 16), moderate (n = 16), or severe (n = 34) CTS and in 20 age- and hand-matched healthy women. The differences among the groups were analyzed using different mixed models of analysis of variance. : A two-way mixed analysis of variance revealed significant differences between groups, not depending on the presence of unilateral or bilateral symptoms (side), for the one-hand pin placement subtest: patients showed bilateral lower scores compared with controls (P < 0.001), without differences among those with minimal, moderate, or severe CTS (P = 0.946). The patients also exhibited lower scores in bilateral pin placement (P < 0.001) and assembly (P < 0.001) subtests, without differences among them. The three-way analysis of variance revealed significant differences among groups (P < 0.001) and fingers (P < 0.001), not depending on the presence of unilateral/bilateral symptoms (P = 0.684), for pinch grip force: patients showed bilateral lower pinch grip force in all fingers compared with healthy controls, without differences among those with minimal, moderate, or severe CTS. : The current study revealed similar bilateral deficits in fine motor control and pinch grip force in patients with minimal, moderate, or severe CTS, supporting that fine motor control deficits are a common feature of CTS not associated with electrodiagnostic findings.

  9. Emergence of cracks by mass transport in elastic crystals stressed at high temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, B.; Suo, Z.; Evans, A.G.

    1995-12-31

    Single crystals are used under high temperature and high stresses in hostile environments (usually gases). A void produced in the fabrication process can change shape and volume, as atoms migrate under various thermodynamic forces. A small void under low stress remains rounded in shape, but a large void under high stress evolves to a crack. The material fractures catastrophically when the crack becomes sufficiently large. In this article three kinetic processes are analyzed: diffusion along the void surface, diffusion in a low melting point second phase inside the void, and surface reaction with the gases. An approximate evolution path ismore » simulated, with the void evolving as a sequence of spheroids, from a sphere to a penny-shaped crack. The free energy is calculated as a functional of void shape, from which the instability conditions are determined. The evolution rate is calculated by using variational principles derived from the valance of the reduction in the free energy and the dissipation is the kinetic processes. Crystalline anisotropy and surface heterogeneity can be readily incorporated in this energetic framework. Comparisons are made with experimental strength date for sapphire fibers measured at various strain rates.« less

  10. Change in the temporal coordination of the finger joints with ulnar nerve block during different power grips analyzed with a sensor glove.

    PubMed

    Wachter, N J; Mentzel, M; Häderer, C; Krischak, G D; Gülke, J

    2018-02-01

    Ulnar nerve injuries can cause deficient hand movement patterns. Their assessment is important for diagnosis and rehabilitation in hand surgery cases. The purpose of this study was to quantify the changes in temporal coordination of the finger joints during different power grips with an ulnar nerve block by means of a sensor glove. In 21 healthy subjects, the onset and end of the active flexion of the 14 finger joints when gripping objects of different diameters was recorded by a sensor glove. The measurement was repeated after an ulnar nerve block was applied in a standardized setting. The change in the temporal coordination of the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints with and without the nerve block was calculated within the same subject. In healthy subjects, the MCP joints started their movement prior to the PIP joints in the middle and ring finger, whereas this occurred in the reverse order at the index and little finger. The DIP joint onset was significantly delayed (P<0.01). With the ulnar nerve block, this coordination shifted towards simultaneous onset of all joints, independent of the grip diameter. The thumb and index finger were affected the least. With an ulnar nerve block, the PIP joints completed their movement prior to the MCP joints when gripping small objects (G1 and G2), whereas the order was reversed with larger objects (G3 and G4). The alterations with ulnar nerve block affected mainly the little finger when gripping small objects. With larger diameter objects, all fingers had a significant delay at the end of the PIP joint movement relative to the MCP and DIP joints, and the PIP and DIP joint sequence was reversed (P<0.01). Based on the significant changes in temporal coordination of finger flexion during different power grips, there are biomechanical effects of loss of function of the intrinsic muscles caused by an ulnar nerve block on the fine motor skills of the hand. This can be important for the diagnosis and rehabilitation of ulnar nerve lesions of the hand. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  11. Influence of the type of training task on intermanual transfer effects in upper-limb prosthesis training: A randomized pre-posttest study.

    PubMed

    Romkema, Sietske; Bongers, Raoul M; van der Sluis, Corry K

    2017-01-01

    Intermanual transfer, the transfer of motor skills from the trained hand to the untrained hand, can be used to train upper limb prosthesis skills. The aim of this study was to determine the relation between the magnitude of the intermanual transfer effect and the type of training task. The used tasks were based on different aspects of prosthetic handling: reaching, grasping, grip-force production and functional tasks. A single-blinded clinical trial, with a pre-posttest design was executed. Seventy-one able-bodied, right-handed participants were randomly assigned to four training and two control groups. The training groups performed a training program with an upper-limb prosthesis simulator. One control group performed a sham training (a dummy training without the prosthesis simulator) and another control group received no training at all. The training groups and sham group trained on five consecutive days. To determine the improvement in skills, a test was administered before, immediately after, and one week after the training. Training was performed with the 'unaffected' arm; tests were performed with the 'affected' arm, with the latter resembling the amputated limb. In this study half of the participants trained with the dominant hand, while the other half trained with the non-dominant hand. Participants executed four tests that corresponded to the different training tasks. The tests measured the reaching (movement time and symmetry ratio), grasping (opening time, duration of maximum hand opening, and closing time), grip-force production (deviation of asked grip-force) and functional (movement time) performance. Half of the participants were tested with their dominant arm and half of the participants with their non-dominant arm. Intermanual transfer effects were not found for reaching, grasping or functional tasks. However, we did find intermanual transfer effects for grip-force production tasks. Possibly, the study design contributed to the negative results due to the duration of the training sessions and test sessions. The positive results of the grip-force production might be an effect of the specificity of the training, that was totally focused on training grip-force production. When using intermanual transfer training in novice amputees, specific training should be devoted to grip-force.

  12. First Flight of the Gamma-Ray Imager Polarimeter for Solar Flares (GRIPS) Instrument

    NASA Technical Reports Server (NTRS)

    Duncan, Nicole; Saint-Hilaire, P.; Shih, A. Y.; Hurford, G. J.; Bain, H. M.; Amman, M.; Mochizuki, A. B.; Hoberman, J.; Olson, J.; Maruca, B. A.; hide

    2016-01-01

    The Gamma-Ray Imager/Polarimeter for Solar ares (GRIPS) instrument is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of flare emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution less than 1cu mm. For photons that Compton scatter, usually greater or equal to 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM grid-imaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi-continuous FWHM angular coverage from 12.5-162 arcsecs are achieved by varying the slit pitch between 1-13 mm. This angular resolution is capable of imaging the separate magnetic loop footpoint emissions in a variety of are sizes. In comparison, RHESSI's 35-arcsec resolution at similar energies makes the footpoints resolvable in only the largest ares.

  13. Influence of the type of training task on intermanual transfer effects in upper-limb prosthesis training: A randomized pre-posttest study

    PubMed Central

    Romkema, Sietske; Bongers, Raoul M.; van der Sluis, Corry K.

    2017-01-01

    Intermanual transfer, the transfer of motor skills from the trained hand to the untrained hand, can be used to train upper limb prosthesis skills. The aim of this study was to determine the relation between the magnitude of the intermanual transfer effect and the type of training task. The used tasks were based on different aspects of prosthetic handling: reaching, grasping, grip-force production and functional tasks. A single-blinded clinical trial, with a pre-posttest design was executed. Seventy-one able-bodied, right-handed participants were randomly assigned to four training and two control groups. The training groups performed a training program with an upper-limb prosthesis simulator. One control group performed a sham training (a dummy training without the prosthesis simulator) and another control group received no training at all. The training groups and sham group trained on five consecutive days. To determine the improvement in skills, a test was administered before, immediately after, and one week after the training. Training was performed with the ‘unaffected’ arm; tests were performed with the ‘affected’ arm, with the latter resembling the amputated limb. In this study half of the participants trained with the dominant hand, while the other half trained with the non-dominant hand. Participants executed four tests that corresponded to the different training tasks. The tests measured the reaching (movement time and symmetry ratio), grasping (opening time, duration of maximum hand opening, and closing time), grip-force production (deviation of asked grip-force) and functional (movement time) performance. Half of the participants were tested with their dominant arm and half of the participants with their non-dominant arm. Intermanual transfer effects were not found for reaching, grasping or functional tasks. However, we did find intermanual transfer effects for grip-force production tasks. Possibly, the study design contributed to the negative results due to the duration of the training sessions and test sessions. The positive results of the grip-force production might be an effect of the specificity of the training, that was totally focused on training grip-force production. When using intermanual transfer training in novice amputees, specific training should be devoted to grip-force. PMID:29190727

  14. Effect of cervical vs. thoracic spinal manipulation on peripheral neural features and grip strength in subjects with chronic mechanical neck pain: a randomized controlled trial.

    PubMed

    Bautista-Aguirre, Francisco; Oliva-Pascual-Vaca, Ángel; Heredia-Rizo, Alberto M; Boscá-Gandía, Juan J; Ricard, François; Rodriguez-Blanco, Cleofás

    2017-06-01

    Cervical and thoracic spinal manipulative therapy has shown positive impact for relief of pain and improve function in non-specific mechanical neck pain. Several attempts have been made to compare their effectiveness although previous studies lacked a control group, assessed acute neck pain or combined thrust and non-thrust techniques. To compare the immediate effects of cervical and thoracic spinal thrust manipulations on mechanosensitivity of upper limb nerve trunks and grip strength in patients with chronic non-specific mechanical neck pain. Randomized, single-blinded, controlled clinical trial. Private physiotherapy clinical consultancy. Eighty-eight subjects (32.09±6.05 years; 72.7% females) suffering neck pain (grades I or II) of at least 12 weeks of duration. Participants were distributed into three groups: 1) cervical group (N.=28); 2) thoracic group (N.=30); and 3) control group (N.=30). One treatment session consisting of applying a high-velocity low-amplitude spinal thrust technique over the lower cervical spine (C7) or the upper thoracic spine (T3) was performed, while the control group received a sham-manual contact. Measurements were taken at baseline and after intervention of the pressure pain threshold over the median, ulnar and radial nerves. Secondary measures included assessing free-pain grip strength with a hydraulic dynamometer. No statistically significant differences were observed when comparing between-groups in any of the outcome measures (P>0.05). Those who received thrust techniques, regardless of the manipulated area, reported an immediate increase in mechanosensitivity over the radial (both sides) and left ulnar nerve trunks (P<0.05), and grip strength (P<0.001). For those in the control group, right hand grip strength and pain perception over the radial nerve also improved (P≤0.025). Low-cervical and upper-thoracic thrust manipulation is no more effective than placebo to induce immediate changes on mechanosensitivity of upper limb nerve trunks and grip strength in patients with chronic non-specific mechanical neck pain. A single treatment session using cervical or thoracic thrust techniques is not enough to achieve clinically relevant changes on neural mechanosensitivity and grip strength in chronic non-specific mechanical neck pain.

  15. Investigation on the frailty status of the elderly inpatients in Shanghai using the FRAIL (fatigue, resistance, ambulation, illness, and loss) questionnaire.

    PubMed

    Wei, Yin; Cao, Yanpei; Yang, Xiaoli; Xu, Yan

    2018-05-01

    This study was to investigate the frailty status of inpatients older than 65 years old in Shanghai.A 6-month cross-sectional survey was conducted using FRAIL (fatigue, resistance, ambulation, illness, and loss) questionnaire. Totally 587 patients were included. The data, including demographic characteristics, constipation, urinary retention, urinary incontinence, grip strength, and muscle strength, were collected. The data of serum prealbumin, serum albumin, serum total protein, and hemoglobin were obtained from laboratory blood tests.The incidence of nonfrailty, prefrailty, and frailty was 0.249, 0.417, and 0.334, respectively. The high incidence age of frailty was 86 to 90 years old (0.342), and the high incidence age of prefrailty was 65 to 70 years old (0.282). There was significant difference in the grip strength among different degrees of frailty (P < .01). The influencing factors related to prefrailty included prealbumin, grip strength, urinary retention, constipation and education level of illiterate (P < .05). The populations with high prealbumin level, high grip strength and illiteracy population were not easy to enter the prefrailty period, while those with constipation (OR (odds ratio) = 1.867, 95% CI (confidence interval): 1.046-3.330) and urinary retention (OR = 7.007, 95% CI: 1.137-2.757) were more likely to enter the prefrailty period. Factors associated with frailty included age, prealbumin, grip strength, muscle strength, urinary incontinence, urinary retention, and constipation (P < .05). The populations with high prealbumin level, high grip strength, and high muscle strength were not easy to enter frailty period, while those with older age (OR = 1.141, 95% CI: 1.085-1.200), urinary incontinence (OR = 10.314, 95% CI: 1.950-54.548), urinary retention (OR = 3.058, 95% CI: 1.571-5.952), and constipation (OR = 3.004, 95% CI: 1.540-5.857) were easy to enter frailty period.The high incidence ages of frailty and prefrailty are 86 to 90 years old and 65 to 70 years old, respectively. Age, low education level, low grip strength, low muscle strength, low serum prealbumin, urinary retention, urinary incontinence, and constipation are the risk factors of frailty. It is recommended to include frailty as an indicator in the existing assessment to rate the disease and develop a disease observation plan.

  16. First flight of the Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument

    NASA Astrophysics Data System (ADS)

    Duncan, Nicole; Saint-Hilaire, P.; Shih, A. Y.; Hurford, G. J.; Bain, H. M.; Amman, M.; Mochizuki, B. A.; Hoberman, J.; Olson, J.; Maruca, B. A.; Godbole, N. M.; Smith, D. M.; Sample, J.; Kelley, N. A.; Zoglauer, A.; Caspi, A.; Kaufmann, P.; Boggs, S.; Lin, R. P.

    2016-07-01

    The Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument is a balloon-borne telescope designed to study solar- are particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of are emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution <1 mm3. For photons that Compton scatter, usually > 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM gridimaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi-continuous FWHM angular coverage from 12.5-162 arcsecs are achieved by varying the slit pitch between 1-13 mm. This angular resolution is capable of imaging the separate magnetic loop footpoint emissions in a variety of are sizes. In comparison, RHESSI's 35-arcsec resolution at similar energies makes the footpoints resolvable in only the largest ares.

  17. The influence of cooling forearm/hand and gender on estimation of handgrip strength.

    PubMed

    Cheng, Chih-Chan; Shih, Yuh-Chuan; Tsai, Yue-Jin; Chi, Chia-Fen

    2014-01-01

    Handgrip strength is essential in manual operations and activities of daily life, but the influence of forearm/hand skin temperature on estimation of handgrip strength is not well documented. Therefore, the present study intended to investigate the effect of local cooling of the forearm/hand on estimation of handgrip strength at various target force levels (TFLs, in percentage of MVC) for both genders. A cold pressor test was used to lower and maintain the hand skin temperature at 14°C for comparison with the uncooled condition. A total of 10 male and 10 female participants were recruited. The results indicated that females had greater absolute estimation deviations. In addition, both genders had greater absolute deviations in the middle range of TFLs. Cooling caused an underestimation of grip strength. Furthermore, a power function is recommended for establishing the relationship between actual and estimated handgrip force. Statement of relevance: Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the forearm/hand tended to cause underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Practitioner Summary: It is important to understand the effect of lowering the forearm/hand skin temperature on grip-strength estimation. A cold pressor was used to cool the hand. The cooling caused underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the forearm/hand tended to cause underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. It is important to understand the effect of lowering the forearm/hand skin temperature on grip-strength estimation. A cold pressor was used to cool the hand. The cooling caused underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force

  18. Impact of Temperature and Non-Gaussian Statistics on Electron Transfer in Donor–Bridge–Acceptor Molecules

    DOE PAGES

    Waskasi, Morteza M.; Newton, Marshall D.; Matyushov, Dmitry V.

    2017-03-16

    A combination of experimental data and theoretical analysis provides evidence of a bell-shaped kinetics of electron transfer in the Arrhenius coordinates ln k vs 1/T . This kinetic law is a temperature analog of the familiar Marcus bell-shaped dependence based on ln k vs the reaction free energy. These results were obtained for reactions of intramolecular charge shift between the donor and acceptor separated by a rigid spacer studied experimentally by Miller and co-workers. The non-Arrhenius kinetic law is a direct consequence of the solvent reorganization energy and reaction driving force changing approximately as hyperbolic functions with temperature. The reorganizationmore » energy decreases and the driving force increases when temperature is increased. The point of equality between them marks the maximum of the activationless reaction rate. Reaching the consistency between the kinetic and thermodynamic experimental data requires the non-Gaussian statistics of the donor-acceptor energy gap described by the Q-model of electron transfer. Furthermore, the theoretical formalism combines the vibrational envelope of quantum vibronic transitions with the Q-model describing the classical component of the Franck-Condon factor and a microscopic solvation model of the solvent reorganization energy and the reaction free energy.« less

  19. Comparison of dynamic contrast-enhanced MRI parameters of breast lesions at 1.5 and 3.0 T: a pilot study

    PubMed Central

    Pineda, F D; Medved, M; Fan, X; Ivancevic, M K; Abe, H; Shimauchi, A; Newstead, G M

    2015-01-01

    Objective: To compare dynamic contrast-enhanced (DCE) MRI parameters from scans of breast lesions at 1.5 and 3.0 T. Methods: 11 patients underwent paired MRI examinations in both Philips 1.5 and 3.0 T systems (Best, Netherlands) using a standard clinical fat-suppressed, T1 weighted DCE-MRI protocol, with 70–76 s temporal resolution. Signal intensity vs time curves were fit with an empirical mathematical model to obtain semi-quantitative measures of uptake and washout rates as well as time-to-peak enhancement (TTP). Maximum percent enhancement and signal enhancement ratio (SER) were also measured for each lesion. Percent differences between parameters measured at the two field strengths were compared. Results: TTP and SER parameters measured at 1.5 and 3.0 T were similar; with mean absolute differences of 19% and 22%, respectively. Maximum percent signal enhancement was significantly higher at 3 T than at 1.5 T (p = 0.006). Qualitative assessment showed that image quality was significantly higher at 3 T (p = 0.005). Conclusion: Our results suggest that TTP and SER are more robust to field strength change than other measured kinetic parameters, and therefore measurements of these parameters can be more easily standardized than measurements of other parameters derived from DCE-MRI. Semi-quantitative measures of overall kinetic curve shape showed higher reproducibility than do discrete classification of kinetic curve early and delayed phases in a majority of the cases studied. Advances in knowledge: Qualitative measures of curve shape are not consistent across field strength even when acquisition parameters are standardized. Quantitative measures of overall kinetic curve shape, by contrast, have higher reproducibility. PMID:25785918

  20. Non-equilibrium plasma kinetics of reacting CO: an improved state to state approach

    NASA Astrophysics Data System (ADS)

    Pietanza, L. D.; Colonna, G.; Capitelli, M.

    2017-12-01

    Non-equilibrium plasma kinetics of reacting CO for conditions typically met in microwave discharges have been developed based on the coupling of excited state kinetics and the Boltzmann equation for the electron energy distribution function (EEDF). Particular attention is given to the insertion in the vibrational kinetics of a complete set of electron molecule resonant processes linking the whole vibrational ladder of the CO molecule, as well as to the role of Boudouard reaction, i.e. the process of forming CO2 by two vibrationally excited CO molecules, in shaping the vibrational distribution of CO and promoting reaction channels assisted by vibrational excitation (pure vibrational mechanisms, PVM). PVM mechanisms can become competitive with electron impact dissociation processes (DEM) in the activation of CO. A case study reproducing the conditions of a microwave discharge has been considered following the coupled kinetics also in the post discharge conditions. Results include the evolution of EEDF in discharge and post discharge conditions highlighting the role of superelastic vibrational and electronic collisions in shaping the EEDF. Moreover, PVM rate coefficients and DEM ones are studied as a function of gas temperature, showing a non-Arrhenius behavior, i.e. the rate coefficients increase with decreasing gas temperature as a result of a vibrational-vibrational (V-V) pumping up mechanism able to form plateaux in the vibrational distribution function. The accuracy of the results is discussed in particular in connection to the present knowledge of the activation energy of the Boudouard process.

  1. How Predictive Is Grip Force Control in the Complete Absence of Somatosensory Feedback?

    ERIC Educational Resources Information Center

    Nowak, Dennis A.; Glasauer, Stefan; Hermsdorfer, Joachim

    2004-01-01

    Grip force control relies on accurate internal models of the dynamics of our motor system and the external objects we manipulate. Internal models are not fixed entities, but rather are trained and updated by sensory experience. Sensory feedback signals relevant object properties and mechanical events, e.g. at the skin-object interface, to modify…

  2. Coefficient of friction of dry slash pine and southern red oak on three tension-grip facings

    Treesearch

    T.J. Lemoine; P. Koch

    1975-01-01

    A urethane material proved to have nine times higher static friction coefficient (0.9) than smooth steel (0.1) on radial and tangential wood surfaces pulled parallel to the grain. It is probably superior to 22O-grit garnet paper or sand coatings for tension-grip facings in lumber testing machines.

  3. Coefficient of friction of dry slash pine and southern red oak on three tension-grip facings

    Treesearch

    Truett J. Lemoine; Peter Koch

    1974-01-01

    A urethane material proved to have nine times higher static friction coefficient (0.9) than smooth steel (0.1) on radial and tangential wood surfaces pulled parallel to the grain. It is probably superior to 220-grit garnet paper or sand coatings for tension-grip facings in lumber testing machines.

  4. Bimanual Force Coordination in Children with Spastic Unilateral Cerebral Palsy

    ERIC Educational Resources Information Center

    Smits-Engelsman, B. C. M.; Klingels, K.; Feys, H.

    2011-01-01

    In this study bimanual grip-force coordination was quantified using a novel "Gripper" system that records grip forces produced while holding a lower and upper unit, in combination with the lift force necessary to separate these units. Children with unilateral cerebral palsy (CP) (aged 5-14 years, n = 12) were compared to age matched typically…

  5. A Developmental Approach to Graduate Education Review: A New Take on a Traditional Process

    ERIC Educational Resources Information Center

    Hakkola, Leah; King, Jean A.

    2016-01-01

    In this article we describe the Graduate Review and Improvement Process (GRIP), an innovative evaluation process that makes student input central, now beginning its fifth year of implementation at the University of Minnesota. We begin by contrasting GRIP with traditional graduate program review, and we then explain the conceptual underpinnings of…

  6. Design of an auto change mechanism and intelligent gripper for the space station

    NASA Technical Reports Server (NTRS)

    Dehoff, Paul H.; Naik, Dipak P.

    1989-01-01

    Robot gripping of objects in space is inherently demanding and dangerous and nowhere is this more clearly reflected than in the design of the robot gripper. An object which escapes the gripper in a micro g environment is launched not dropped. To prevent this, the gripper must have sensors and signal processing to determine that the object is properly grasped, e.g., grip points and gripping forces and, if not, to provide information to the robot to enable closed loop corrections to be made. The sensors and sensor strategies employed in the NASA/GSFC Split-Rail Parallel Gripper are described. Objectives and requirements are given followed by the design of the sensor suite, sensor fusion techniques and supporting algorithms.

  7. Grip Preference, Dermatoglyphics, and Hand Use in Captive Chimpanzees (Pan troglodytes)

    PubMed Central

    Hopkins, William D.; Russell, Jamie L.; Hostetter, Autumn; Pilcher, Dawn; Dahl, Jeremy F.

    2007-01-01

    This paper examined the association between grip type, hand use, and fingerprint patterns in a sample of captive chimpanzees. Grip type for simple reaching was assessed for the left and right hand and classified as thumb-index, middle-index, or single-digit responses. Fingerprint patterns were characterized as whorls, loops, or arches on each finger. The results indicated that chimpanzees exhibit significantly more thumb-index responses for the right compared to the left hand. In addition, thumb-index responses were more prevalent for subjects that had a whorl compared to a loop or arch on their thumb. The results suggest that fingerprint patterns are associated with individual differences in grasping type in chimpanzees as well as some variation in hand use. PMID:15761856

  8. Fluid assisted installation of electrical cable accessories

    DOEpatents

    Mayer, Robert W.; Silva, Frank A.

    1977-01-01

    An electrical cable accessory includes a generally tubular member of elastomeric material which is to be installed by placement over a cylindrical surface to grip the cylindrical surface, when in appropriate assembled relation therewith, with a predetermined gripping force established by dilation of the tubular member, the installation being facilitated by introducing fluid under pressure, through means provided in the tubular member, between the tubular member and the cylindrical surface, and simultaneously impeding the escape of the fluid under pressure from between the tubular member and the cylindrical surface by means adjacent one of the ends of the tubular member to cause dilation of the tubular member and establish a fluid layer between the tubular member and the cylindrical surface, thereby reducing the gripping force during installation.

  9. Analytical study on different blade-shape design of HAWT for wasted kinetic energy recovery system (WKERS)

    NASA Astrophysics Data System (ADS)

    Goh, J. B.; Jamaludin, Z.; Jafar, F. A.; Mat Ali, M.; Mokhtar, M. N. Ali; Tan, C. H.

    2017-06-01

    Wasted kinetic energy recovery system (WKERS) is a wind renewable gadget installed above a cooling tower outlet to harvest the discharged wind for electrical regeneration purpose. The previous WKERS is operated by a horizontal axis wind turbine (HAWT) with delta blade design but the performance is still not at the optimum level. Perhaps, a better blade-shape design should be determined to obtain the optimal performance, as it is believed that the blade-shape design plays a critical role in HAWT. Hence, to determine a better blade-shape design for a new generation of WKERS, elliptical blade, swept blade and NREL Phase IV blade are selected for this benchmarking process. NREL Phase IV blade is a modern HAWT’s blade design by National Renewable Energy Laboratory (NREL) research lab. During the process of benchmarking, Computational Fluid Dynamics (CFD) analysis was ran by using SolidWorks design software, where all the designs are simulated with linear flow simulation. The wind speed in the simulation is set at 10.0 m/s, which is compatible with the average wind speed produced by a standard size cooling tower. The result is obtained by flow trajectories of air motion, surface plot and cut plot of the applied blade-shape. Besides, the aspect ratio of each blade is calculated and included as one of the reference in the comparison. Hence, the final selection of the best blade-shape design will bring to the new generation of WKERS.

  10. The battle scars of pregnancy: can they be prevented?

    PubMed

    Razi, Emma

    2012-05-01

    I have feared developing stretch marks since my first pregnancy. Getting to grips with my changing shape was a big challenge, but I was safe in the knowledge that post-pregnancy I could work towards losing the weight. But stretch marks are permanent, and to me-disfiguring. I researched how stretch marks can be prevented and after finding little evidence for a particular cream or lotion: I scanned forums and asked friends what worked for them. Many people claimed that by keeping skin hydrated and supple, the dreaded stretch marks can be kept at bay or at least to a minimum. So I opted for regularly massaging oil across vulnerable areas and maintaining a balanced diet, including drinking lots of water. I was lucky the first time round; time will tell if my skincare routine will work for my second pregnancy.

  11. Preparation of solid lipid nanoparticles as drug carriers for levothyroxine sodium with in vitro drug delivery kinetic characterization.

    PubMed

    Rostami, E; Kashanian, S; Azandaryani, A H

    2014-05-01

    The aim of this work was to produce and characterize solid lipid nanoparticles (SLN) containing levothyroxine sodium for oral administration, and to evaluate the kinetic release of these colloidal carriers. SLNs were prepared by microemulsion method. The particle size and zeta potential of levothyroxine sodium-loaded SLNs were determined to be around 153 nm,-43 mV (negatively charged), respectively by photon correlation spectroscopy. The levothyroxine entrapment efficiency was over 98%. Shape and surface morphology were determined by TEM and SEM. They revealed fairly spherical shape of nanoparticles.SLN formulation was stable over a period of 6 months. There were no significant changes in particle size, zeta potential and polydispersity index and entrapment efficiency, indicating that the developed SLNs were fairly stable.

  12. A new video laryngo-pharyngoscope with shape-holding coiled tube and surgical forceps: a preliminary study.

    PubMed

    Tamura, Koichi; Kim, Masanobu; Abe, Koji; Toda, Naoki; Jinouchi, Osamu; Kalubi, Bukasa; Takeda, Noriaki

    2009-12-01

    We developed a new video laryngo-pharyngoscope with a shape-holding coiled tube and examined its effectiveness in some patients. The video laryngo-pharyngoscope is designed to inspect the pharynx and larynx transorally and to perform surgical manipulations. The scope consists of a coiled tube, a grip with trigger connected to the forceps and a CCD Camera with a battery. The stainless coiled tube of the scope is flexible but shape-holding, so that its shape can be changed by hand with the characteristic that the new orientation remains invariable during both inspection and operation in the pharynx and larynx. After a local anesthesia, the operator holds the scope in one hand and pulls the patient's tongue by the other hand. The operator then inserted the scope transorally while monitoring video images that were wirelessly transferred to the display to ensure that the forceps has reached the area of interest and treated lesions successfully. Using the scope, we successfully examined the upper airway lesions and removed foreign bodies from the pharynx and performed both resection of a benign tumor and taking a biopsy of a malignant tumor from the pharynx and larynx. But, we could hardly remove vocal fold polyps because of the structural limitation of the scope. We demonstrated that the new video laryngo-pharyngoscope can be used safely and successfully in the inspection and removal of lesions in the oropharynx and supraglottic area of the larynx and will be a useful tool for minimally invasive office-based surgery.

  13. Spatiotemporal distribution of location and object effects in reach-to-grasp kinematics

    PubMed Central

    Rouse, Adam G.

    2015-01-01

    In reaching to grasp an object, the arm transports the hand to the intended location as the hand shapes to grasp the object. Prior studies that tracked arm endpoint and grip aperture have shown that reaching and grasping, while proceeding in parallel, are interdependent to some degree. Other studies of reaching and grasping that have examined the joint angles of all five digits as the hand shapes to grasp various objects have not tracked the joint angles of the arm as well. We, therefore, examined 22 joint angles from the shoulder to the five digits as monkeys reached, grasped, and manipulated in a task that dissociated location and object. We quantified the extent to which each angle varied depending on location, on object, and on their interaction, all as a function of time. Although joint angles varied depending on both location and object beginning early in the movement, an early phase of location effects in joint angles from the shoulder to the digits was followed by a later phase in which object effects predominated at all joint angles distal to the shoulder. Interaction effects were relatively small throughout the reach-to-grasp. Whereas reach trajectory was influenced substantially by the object, grasp shape was comparatively invariant to location. Our observations suggest that neural control of reach-to-grasp may occur largely in two sequential phases: the first determining the location to which the arm transports the hand, and the second shaping the entire upper extremity to grasp and manipulate the object. PMID:26445870

  14. Computational Thermodynamics and Kinetics-Based ICME Framework for High-Temperature Shape Memory Alloys

    NASA Astrophysics Data System (ADS)

    Arróyave, Raymundo; Talapatra, Anjana; Johnson, Luke; Singh, Navdeep; Ma, Ji; Karaman, Ibrahim

    2015-11-01

    Over the last decade, considerable interest in the development of High-Temperature Shape Memory Alloys (HTSMAs) for solid-state actuation has increased dramatically as key applications in the aerospace and automotive industry demand actuation temperatures well above those of conventional SMAs. Most of the research to date has focused on establishing the (forward) connections between chemistry, processing, (micro)structure, properties, and performance. Much less work has been dedicated to the development of frameworks capable of addressing the inverse problem of establishing necessary chemistry and processing schedules to achieve specific performance goals. Integrated Computational Materials Engineering (ICME) has emerged as a powerful framework to address this problem, although it has yet to be applied to the development of HTSMAs. In this paper, the contributions of computational thermodynamics and kinetics to ICME of HTSMAs are described. Some representative examples of the use of computational thermodynamics and kinetics to understand the phase stability and microstructural evolution in HTSMAs are discussed. Some very recent efforts at combining both to assist in the design of HTSMAs and limitations to the full implementation of ICME frameworks for HTSMA development are presented.

  15. Influence of Size and Shape of Silica Supports on the Sol⁻Gel Surface Molecularly Imprinted Polymers for Selective Adsorption of Gossypol.

    PubMed

    Zhi, Keke; Wang, Lulu; Zhang, Yagang; Jiang, Yingfang; Zhang, Letao; Yasin, Akram

    2018-05-11

    The influence of various silica gel supports with different shapes and sizes on the recognition properties of surface molecular imprinted polymers (MIPs) was investigated. MIPs for selective recognition and adsorption of gossypol were synthesized via the sol⁻gel process with a surface imprinting technique on silica gel substrates. 3-aminopropyltriethoxysilane (APTES) and tetraethoxysilane (TEOS) were chosen as the functional monomer and the cross-linker. The morphology and structure of the gossypol-MIPs were characterized using Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), and a standard Brunauer⁻Emett⁻Teller (BET) analysis. Results indicated that the surface imprinted polymer layer facilitated the removal and rebinding of the template, and thus, achieved fast binding kinetics. Compared with the MIPs prepared on irregularly shaped silica with a broad particle size distribution, the MIPs using regularly-shaped silica of uniform size showed higher imprinting factor (IF), and the MIP made with a relatively larger sized (60 μm) spherical silica, demonstrated higher adsorption capacity compared to the MIPs made with smaller sized, spherical silica. The MIP prepared with 60 μm spherically shaped silica, featured a fast adsorption kinetic of 10 min, and a saturated adsorption capacity of 204 mg·g −1 . The gossypol-MIP had higher selectivity (IF = 2.20) for gossypol over its structurally-similar analogs ellagic acid (IF = 1.13) and quercetin (IF = 1.20). The adsorption data of the MIP correlated well with the pseudo-second-order kinetic model and the Freundlich isotherm model, which implied that chemical adsorption dominated, and that multilayer adsorption occurred. Furthermore, the MIP exhibited an excellent regeneration performance, and the adsorption capacity of the MIP for gossypol only decreased by 6% after six reused cycles, indicating good application potential for selective adsorption of gossypol.

  16. Diffusive and martensitic nucleation kinetics in solid-solid transitions of colloidal crystals

    NASA Astrophysics Data System (ADS)

    Peng, Yi; Li, Wei; Wang, Feng; Still, Tim; Yodh, Arjun G.; Han, Yilong

    2017-05-01

    Solid-solid transitions between crystals follow diffusive nucleation, or various diffusionless transitions, but these kinetics are difficult to predict and observe. Here we observed the rich kinetics of transitions from square lattices to triangular lattices in tunable colloidal thin films with single-particle dynamics by video microscopy. Applying a small pressure gradient in defect-free regions or near dislocations markedly transform the diffusive nucleation with an intermediate-stage liquid into a martensitic generation and oscillation of dislocation pairs followed by a diffusive nucleus growth. This transformation is neither purely diffusive nor purely martensitic as conventionally assumed but a combination thereof, and thus presents new challenges to both theory and the empirical criterion of martensitic transformations. We studied how pressure, density, grain boundary, triple junction and interface coherency affect the nucleus growth, shape and kinetic pathways. These novel microscopic kinetics cast new light on control solid-solid transitions and microstructural evolutions in polycrystals.

  17. Diffusive and martensitic nucleation kinetics in solid-solid transitions of colloidal crystals

    PubMed Central

    Peng, Yi; Li, Wei; Wang, Feng; Still, Tim; Yodh, Arjun G.; Han, Yilong

    2017-01-01

    Solid–solid transitions between crystals follow diffusive nucleation, or various diffusionless transitions, but these kinetics are difficult to predict and observe. Here we observed the rich kinetics of transitions from square lattices to triangular lattices in tunable colloidal thin films with single-particle dynamics by video microscopy. Applying a small pressure gradient in defect-free regions or near dislocations markedly transform the diffusive nucleation with an intermediate-stage liquid into a martensitic generation and oscillation of dislocation pairs followed by a diffusive nucleus growth. This transformation is neither purely diffusive nor purely martensitic as conventionally assumed but a combination thereof, and thus presents new challenges to both theory and the empirical criterion of martensitic transformations. We studied how pressure, density, grain boundary, triple junction and interface coherency affect the nucleus growth, shape and kinetic pathways. These novel microscopic kinetics cast new light on control solid–solid transitions and microstructural evolutions in polycrystals. PMID:28504246

  18. Significance of finger forces and kinematics during handwriting in writer's cramp.

    PubMed

    Hermsdörfer, Joachim; Marquardt, Christian; Schneider, Alexandra S; Fürholzer, Waltraud; Baur, Barbara

    2011-08-01

    Muscular hyperactivity during handwriting, irregular and jerky scripts, as well as awkward and slowed pen movements are the cardinal symptoms of writer's cramp. Accordingly, impaired kinematics and increased force have been reported in writer's cramp. However, the relationship between these symptoms has rarely been investigated. In addition, measurements of finger forces have been restricted to the vertical pen pressure. In the present study, the pen of a graphic tablet was equipped with a force sensor matrix to measure also the grip force produced against the pen barrel despite highly variable pen grips of the patients. Kinematics of writing movements, vertical pen pressure, and grip force were compared in 27 patients with writer's cramp and normal control writers during writing of a test sentence. As expected, all measures revealed a significantly worse writing performance in the patients compared to the control subjects. Exaggerated forces were more frequent than abnormal kinematics, and evidenced by prolonged movement times and reduced writing frequencies. Correlations were found neither between kinematics and force measures nor between the two forces. Interestingly, patients relaxed the grip force during short periods of non-writing by the same relative amount as control subjects. The finding of a large heterogeneity of performances patterns in writer's cramp may reflect the variability of dystonic symptoms as well as the highly variable compensatory strategies of individual patients. Measurements of finger force and in particular of the grip force are valuable and important descriptors of individual impairment characteristics that are independent of writing kinematics. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Using Goal- and Grip-Related Information for Understanding the Correctness of Other’s Actions: An ERP Study

    PubMed Central

    van Elk, Michiel; Bousardt, Roel; Bekkering, Harold; van Schie, Hein T.

    2012-01-01

    Detecting errors in other’s actions is of pivotal importance for joint action, competitive behavior and observational learning. Although many studies have focused on the neural mechanisms involved in detecting low-level errors, relatively little is known about error-detection in everyday situations. The present study aimed to identify the functional and neural mechanisms whereby we understand the correctness of other’s actions involving well-known objects (e.g. pouring coffee in a cup). Participants observed action sequences in which the correctness of the object grasped and the grip applied to a pair of objects were independently manipulated. Observation of object violations (e.g. grasping the empty cup instead of the coffee pot) resulted in a stronger P3-effect than observation of grip errors (e.g. grasping the coffee pot at the upper part instead of the handle), likely reflecting a reorienting response, directing attention to the relevant location. Following the P3-effect, a parietal slow wave positivity was observed that persisted for grip-errors, likely reflecting the detection of an incorrect hand-object interaction. These findings provide new insight in the functional significance of the neurophysiological markers associated with the observation of incorrect actions and suggest that the P3-effect and the subsequent parietal slow wave positivity may reflect the detection of errors at different levels in the action hierarchy. Thereby this study elucidates the cognitive processes that support the detection of action violations in the selection of objects and grips. PMID:22606261

  20. Dietary Variety and Decline in Lean Mass and Physical Performance in Community-Dwelling Older Japanese: A 4-year Follow-Up Study.

    PubMed

    Yokoyama, Y; Nishi, M; Murayama, H; Amano, H; Taniguchi, Y; Nofuji, Y; Narita, M; Matsuo, E; Seino, S; Kawano, Y; Shinkai, S

    2017-01-01

    To examine associations of dietary variety with changes in lean mass and physical performance during a 4-year period in an elderly Japanese population. Four-year prospective study. The Hatoyama Cohort Study and Kusatsu Longitudinal Study, Japan. 935 community-dwelling Japanese aged 65 years or older. Dietary variety was assessed using a 10-item food frequency questionnaire. Body composition was determined by multifrequency bioelectrical impedance analysis, and physical performance (grip strength and usual gait speed) was measured in surveys at baseline and 4 years later. Longitudinal analysis included only participants who were originally in the upper three quartiles of lean body mass, appendicular lean mass, grip strength, and usual gait speed. The outcome measures were decline in lean body mass, appendicular lean mass, grip strength, and usual gait speed, defined as a decrease to the lowest baseline quartile level at the 4-year follow-up survey. Associations of dietary variety with the outcome measures were examined by logistic regression analysis adjusted for potential confounders. In the fully adjusted model, the odds ratios for decline in grip strength and usual gait speed were 0.43 (95% confidence interval, 0.19-0.99) and 0.43 (confidence interval, 0.19-0.99), respectively, for participants in the highest category of dietary variety score as compared with those in the lowest category. Dietary variety was not significantly associated with changes in lean body mass or appendicular lean mass. Among older adults, greater dietary variety may help maintain physical performance, such as grip strength and usual gait speed, but not lean mass.

  1. Hand grips strength effect on motor function in human brain using fMRI: a pilot study

    NASA Astrophysics Data System (ADS)

    Ismail, S. S.; Mohamad, M.; Syazarina, S. O.; Nafisah, W. Y.

    2014-11-01

    Several methods of motor tasks for fMRI scanning have been evolving from simple to more complex tasks. Motor tasks on upper extremity were applied in order to excite the increscent of motor activation on contralesional and ipsilateral hemispheres in brain. The main objective of this study is to study the different conditions for motor tasks on upper extremity that affected the brain activation. Ten healthy right handed with normal vision (3 male and 7 female, age range=20-30 years, mean=24.6 years, SD=2.21) participated in this study. Prior to the scanning, participants were trained on hand grip tasks using rubber ball and pressure gauge tool outside the scanner. During fMRI session, a block design with 30-s task blocks and alternating 30-s rest periods was employed while participants viewed a computer screen via a back projection-mirror system and instructed to follow the instruction by gripping their hand with normal and strong grips using a rubber ball. Statistical Parametric mapping (SPM8) software was used to determine the brain activation. Both tasks activated the primary motor (M1), supplementary motor area (SMA), dorsal and ventral of premotor cortex area (PMA) in left hemisphere while in right hemisphere the area of primary motor (M1) somatosensory was activated. However, the comparison between both tasks revealed that the strong hand grip showed the higher activation at M1, PMA and SMA on left hemisphere and also the area of SMA on right hemisphere. Both conditions of motor tasks could provide insights the functional organization on human brain.

  2. Compression plate arthrodesis for osteoarthritis of the first carpometacarpal joint: A retrospective study of 77 cases.

    PubMed

    Harenberg, P S; Langer, M F; Sproedt, J; Grünert, J G

    2018-02-01

    Osteoarthritis of the first carpometacarpal joint (CMCJ1) is a common, painful condition with positive radiological findings in up to 32% of people over 50 years of age and up to 91% of people over 80 years of age. Currently, there is insufficient evidence to recommend one surgical treatment option over the others. We conducted a retrospective review of 77 patients treated for CMCJ1 osteoarthritis with plate arthrodesis between 1979 and 1996. The review included physical examination, including range of motion (ROM) of the thumb interphalangeal joint, metacarpophalangeal joint and CMCJ1, pinch grip, key grip and power grip strength, and a questionnaire on subjective outcomes (appearance, dexterity, load bearing, pain, strength, subjective overall result and if patients would choose the procedure again). The complication rate was 26%. However, the general patient satisfaction was high with 88% of patients saying they would choose to have the procedure done again. There was a significant decrease (side-to-side difference) in the ROM for palmar and radial abduction as well as opposition when compared to the opposite hand. Furthermore, there was a significant reduction (side-to-side difference) in pinch, key grip and power grip strength. ROM did not seem to have any influence on pain (and vice versa), load bearing, and the subjective overall result. No gender differences were noted. Despite the high complication rate, CMCJ1 arthrodesis remains a viable option for the treatment of CMCJ1 osteoarthritis in select patients requiring good thumb stability. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  3. Persistence of myopathy in Cushing's syndrome: evaluation of the German Cushing's Registry.

    PubMed

    Berr, Christina M; Stieg, Mareike R; Deutschbein, Timo; Quinkler, Marcus; Schmidmaier, Ralf; Osswald, Andrea; Reisch, Nicole; Ritzel, Katrin; Dimopoulou, Christina; Fazel, Julia; Hahner, Stefanie; Stalla, Günter K; Beuschlein, Felix; Reincke, Martin

    2017-06-01

    Cushing's syndrome (CS) is characterized by an excessive secretion of glucocorticoids that results in a characteristic clinical phenotype. One feature of clinical hypercortisolism is breakdown of protein metabolism translating into clinical consequences including glucocorticoid-induced myopathy. While surgery is effective in control of cortisol excess, the effect of biochemical remission on muscular function is yet unclear. In a cross-sectional study we analyzed 47 patients with CS during the florid phase (ActiveCS). 149 additional patients were studied 2-53 years (mean: 13 years) after surgery in biochemical long-term remission (RemissionCS). Also, 93 rule-out CS patients were used as controls (CON). All subjects were assessed for grip strength using a hand grip dynamometer and underwent the chair rising test (CRT). Hand grip strength (85% vs 97% of norm, P  = 0.002) and the CRT performance (9.5 s vs 7.1 s, P  = 0.001) were significantly lower in ActiveCS compared to the CON group. Six months after treatment grip strength further decreased in CS ( P  = 0.002) and CRT performance remained impaired. The RemissionCS group (mean follow-up 13 years) had reduced hand grip strength (92% compared to normal reference values for dominant hand, P  < 0.001). The chair rising test performance was at 9.0 s and not significantly different from the ActiveCS group ( P  = 0.45). CS affects muscle strength in the acute phase, but functional impairment remains detectable also during long-term follow-up despite biochemical remission. © 2017 European Society of Endocrinology.

  4. Secular change in muscular strength of indigenous rural youth 6-17 years in Oaxaca, southern Mexico: 1968-2000.

    PubMed

    Malina, Robert M; Reyes, Maria Eugenia Peña; Tan, Swee Kheng; Little, Bertis B

    2010-04-01

    The study compared the grip strength of indigenous school youth 6-17 years of age in Oaxaca, southern Mexico, who were surveyed in 1968, 1978 and 2000. Grip strength (Smedley/Stoelting) was measured to 0.5 kg in 1280 children and adolescent, 621 males and 659 females, in the three surveys. Height and weight were also measured. Strength of the right and left hands was summed to provide a general estimate of muscular strength. Summed grip strength was also expressed per unit body mass (kg/kg) and height (kg/m). Subjects were classified into four age groups: 6-8 years (childhood), 9-11 years (transition in adolescence), 12-14 years (early adolescence) and 15-17 years (later adolescence). Children 6-14 years were surveyed in 1968, 1978 and 2000 while adolescents 15-17 years were surveyed in 1978 and 2000. Sex-specific MANCOVAs were used for comparisons among years within age groups. Changes in grip strength between 1968 and 1978 among children 6-14 years were small and significant only in girls. Grip strength increased, on average, between 1978 and 2000 in boys 6-17 years but only in girls 6-14 years; adolescent girls 15-17 years in 1978 were stronger than those in 2000. Secular gains in muscular strength were generally proportional to secular gains in body weight and height. The data demonstrate secular changes in muscular strength in indigenous rural youth in a community in the process of transition from subsistence level agriculture to an economy less dependent upon agriculture.

  5. [Study of mechanical effects of the EVA glove on finger base with finite element modeling].

    PubMed

    Li, Zhuoyou; Ding, Li; Yue, Guodong

    2013-08-01

    The hand strength of astronauts, when they are outside the space capsule, is highly influenced by the residual pressure (the pressure difference between inside pressure and outside one of the suit) of extravehicular activity spacesuit glove and the pressure exerted by braided fabric. The hand strength decreases significantly on extravehicular activity, severely reducing the operation efficiency. To measure mechanical influence caused by spacesuit glove on muscle-tendon and joints, the present paper analyzes the movement anatomy and biomechanical characteristics of gripping, and then proposes a grip model. With phalangeal joint simplified as hinges, seven muscles as a finger grip energy unit, the Hill muscle model was used to compute the effects. We also used ANSYS in this study to establish a 3-D finite element model of an index finger which included both bones and muscles with glove, and then we verified the model. This model was applied to calculate the muscle stress in various situations of bare hands or hands wearing gloves in three different sizes. The results showed that in order to achieve normal grip strength with the influence caused by superfluous press, the finger's muscle stress should be increased to 5.4 times of that in normal situation, with most of the finger grip strength used to overcome the influence of superfluous pressure. When the gap between the finger surface and the glove is smaller, the mechanical influence which superfluous press made will decrease. The results would provide a theoretical basis for the design of the EVA Glove.

  6. Motor Performance of Women as a Function of Age and Physical Activity Level.

    ERIC Educational Resources Information Center

    Rikli, Roberta; Busch, Sharman

    Two studies compared motor skills of women in terms of the influence of age and activity level. In the first study, simple and choice reaction time, balance, flexibility, and grip strength of older active women were compared with that of older inactive women, and active and inactive younger women. Except for grip strength, scores of older active…

  7. iss056e009782

    NASA Image and Video Library

    2018-06-11

    iss056e009782 (June 11, 2018) --- Expedition 56 Flight Engineer Alexander Gerst of the European Space Agency (ESA) is seated in the Columbus laboratory module participating in the Grip study. Grip is an ESA-sponsored experiment that is researching how the nervous system adapts to microgravity. Observations may improve the design of safer space habitats and help patients on Earth with neurological diseases.

  8. Grip Force Control Is Dependent on Task Constraints in Children with and without Developmental Coordination Disorder

    ERIC Educational Resources Information Center

    Law, Sui-Heung; Lo, Sing Kai; Chow, Susanna; Cheing, Gladys L.Y.

    2011-01-01

    Excessive grip force (GF) is often found in children with developmental coordination disorder (DCD). However, their GF control may vary when task constraints are imposed upon their motor performance. This study aimed to investigate how their GF control changes in response to task demands, and to examine their tactile sensitivity. Twenty-one…

  9. Role of the Visuomotor System in On-Line Attenuation of a Premovement Illusory Bias in Grip Aperture

    ERIC Educational Resources Information Center

    Heath, M.; Rival, C.

    2005-01-01

    In this investigation participants formulated a grip aperture (GA) consistent with the size of an object embedded within a Muller-Lyer (ML) figure prior to initiating visually guided grasping movements. The accuracy of the grasping response was emphasized to determine whether or not the visuomotor system might resolve the premovement bias in GA…

  10. Simulating cut-to-length harvesting operations in Appalachian hardwoods

    Treesearch

    Jingxin Wang; Chris B. LeDoux; Yaoxiang Li

    2005-01-01

    Cut-to-length (CTL) harvesting systems involving small and large harvesters and a forwarder were simulated using a modular computer simulation model. The two harvesters simulated were a modified John Deere 988 tracked excavator with a single grip sawhead and a Timbco T425 based excavator with a single grip sawhead. The forwarder used in the simulations was a Valmet 524...

  11. Response to Eva Alerby and Cecilia Perm, "Learning Music: Embodied Experience in the Life-World"

    ERIC Educational Resources Information Center

    Fung, C. Victor

    2005-01-01

    At the onset of the essay by Alerby and Perm, musicality is described as emotional or cognitive phenomena. In this response, Fung questions what role a psychomotor phenomenon plays in musicality. Alerby and Perm describe "motor knowledge" in the context of Merleau-Ponty's "maximum grip." Does this mean that "motor knowledge" or "maximum grip" in…

  12. SURGICAL TREATMENT OF DISTAL RADIUS FRACTURES WITH A VOLAR LOCKED PLATE: CORRELATION OF CLINICAL AND RADIOGRAPHIC RESULTS

    PubMed Central

    Xavier, Claudio Roberto Martins; Dal Molin, Danilo Canesin; dos Santos, Rafael Mota Marins; dos Santos, Roberto Della Torre; Neto, Julio Cezar Ferreira

    2015-01-01

    Objectives: To analyze and correlate the clinical and radiographic results from patients with distal radius fractures who underwent surgical treatment with a fixed-angle volar locked plate. Methods: Sixty-four patients with distal radius fractures were evaluated. They all underwent surgical treatment with a volar locked plate for the distal radius, with a minimum of six months of postoperative follow-up. They underwent a physical examination that measured range of motion and grip strength, answered the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and underwent radiographic examination. Results: In the physical examination on the patients, all the range-of-motion measurements were reduced. Grip strength measured in kgf was on average 85.8% of the strength on the unaffected side. The mean DASH score was 15.99. A significant relationship was found between lower DASH scores and losses of extension and grip strength. On the radiographs, the mean values in relation to the unfractured side were 84.0% for radial inclination, 85.4% for radial length and 86.8% for volar deviation of the radius. Loss of radial length was correlated with losses of extension and grip strength. PMID:27027046

  13. Effects of hyperthyroidism on hand grip strength and function.

    PubMed

    Erkol İnal, Esra; Çarlı, Alparslan Bayram; Çanak, Sultan; Aksu, Oğuzhan; Köroğlu, Banu Kale; Savaş, Serpil

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism was confirmed by clinical examination and laboratory tests. Hand grip strength was tested at the dominant hand with a Jamar hand dynamometer. The grooved pegboard test (PGT) was used to evaluate hand dexterity. The Duruöz Hand Index (DHI) was used to assess hand function. No significant differences were found in terms of clinical and demographic findings between the patients with hyperthyroidism and healthy controls (p > 0.05). Significant differences were found between the patients with hyperthyroidism and healthy controls regarding PGT and DHI scores (p < 0.05). Hyperthyroidism seemed to affect hand dexterity and function more than hand grip strength and seemed to be associated with reduced physical function more than muscle strength. This may also indicate that patients with hyperthyroidism should be evaluated by multidisplinary modalities.

  14. Sustained effect of resistance training on blood pressure and hand grip strength following a detraining period in elderly hypertensive women: a pilot study

    PubMed Central

    Nascimento, Dahan da Cunha; Tibana, Ramires Alsamir; Benik, Franklin M; Fontana, Keila Elizabeth; Neto, Frederico Ribeiro; de Santana, Frederico Santos; Santos-Neto, Leopoldo; Silva, Renato André Sousa; Silva, Alessandro Oliveira; Farias, Darlan Lopes; Balsamo, Sandor; Prestes, Jonato

    2014-01-01

    Introduction Hypertension is the most prevalent modifiable risk factor with a high prevalence among older adults. Exercise is a nonpharmacological treatment shown to benefit all patients with hypertension. Objective This study examined the effects of a 14-week moderate intensity resistance training program (RT) on the maintenance of blood pressure and hand grip strength during an extended detraining period in elderly hypertensive women. Methods Twelve hypertensive sedentary elderly women completed 14 weeks of whole body RT at a moderate perceived exertion following a detraining period of 14 weeks. Results Following the training period, participants demonstrated an increase in absolute hand grip strength (P=0.001), relative hand grip strength (P=0.032) and a decrease of systolic (P=0.001), diastolic (P=0.008), and mean blood pressure (P=0.002) when compared to pre-exercise values. In addition, these effects were sustained after 14 weeks of detraining. Conclusion Resistance training may be a valuable method to improve muscular strength and blood pressure in elderly people with benefits being maintained up to 14 weeks following training cessation. PMID:24477221

  15. A Newly Designed Tennis Elbow Orthosis With a Traditional Tennis Elbow Strap in Patients With Lateral Epicondylitis

    PubMed Central

    Saremi, Hossein; Chamani, Vahid; Vahab-Kashani, Reza

    2016-01-01

    Background Lateral epicondylitis is a common cause of pain and upper limb dysfunction. The use of counterforce straps for treatment of lateral epicondylitis is widespread. This kind of orthosis can be modified to have a greater effect on relieving pain by reducing tension on the origin of the extensor pronator muscles. Objectives To determine the immediate effects of a newly designed orthosis on pain and grip strength in patients with lateral epicondylitis. Materials and Methods Twelve participants (six men and six women) were recruited (mean age = 41 ± 6.7 years) and evaluated for pain and grip strength in three sessions. A 48-hour break was taken between each session. The first session was without any orthosis, the second session was with the new modified tennis elbow orthosis, and the third session was with a conventional tennis elbow strap. Results Both counterforce straps were effective. However, significantly more improvement was observed in pain and grip strength after using the newly modified orthosis (P < 0.05). Conclusions The newly designed strap reduces pain more effectively and improves grip strength by causing greater localized pressure on two regions with different force applications (two component vectors versus one). PMID:28180116

  16. Development and characterization of a dynamic lesion phantom for the quantitative evaluation of dynamic contrast-enhanced MRI.

    PubMed

    Freed, Melanie; de Zwart, Jacco A; Hariharan, Prasanna; Myers, Matthew R; Badano, Aldo

    2011-10-01

    To develop a dynamic lesion phantom that is capable of producing physiological kinetic curves representative of those seen in human dynamic contrast-enhanced MRI (DCE-MRI) data. The objective of this phantom is to provide a platform for the quantitative comparison of DCE-MRI protocols to aid in the standardization and optimization of breast DCE-MRI. The dynamic lesion consists of a hollow, plastic mold with inlet and outlet tubes to allow flow of a contrast agent solution through the lesion over time. Border shape of the lesion can be controlled using the lesion mold production method. The configuration of the inlet and outlet tubes was determined using fluid transfer simulations. The total fluid flow rate was determined using x-ray images of the lesion for four different flow rates (0.25, 0.5, 1.0, and 1.5 ml/s) to evaluate the resultant kinetic curve shape and homogeneity of the contrast agent distribution in the dynamic lesion. High spatial and temporal resolution x-ray measurements were used to estimate the true kinetic curve behavior in the dynamic lesion for benign and malignant example curves. DCE-MRI example data were acquired of the dynamic phantom using a clinical protocol. The optimal inlet and outlet tube configuration for the lesion molds was two inlet molds separated by 30° and a single outlet tube directly between the two inlet tubes. X-ray measurements indicated that 1.0 ml/s was an appropriate total fluid flow rate and provided truth for comparison with MRI data of kinetic curves representative of benign and malignant lesions. DCE-MRI data demonstrated the ability of the phantom to produce realistic kinetic curves. The authors have constructed a dynamic lesion phantom, demonstrated its ability to produce physiological kinetic curves, and provided estimations of its true kinetic curve behavior. This lesion phantom provides a tool for the quantitative evaluation of DCE-MRI protocols, which may lead to improved discrimination of breast cancer lesions.

  17. The kinetic friction of ZnO nanowires on amorphous SiO2 and SiN substrates

    NASA Astrophysics Data System (ADS)

    Roy, Aditi; Xie, Hongtao; Wang, Shiliang; Huang, Han

    2016-12-01

    ZnO nanowires were bent on amorphous SiO2 and SiN substrates in an ambient atmosphere using optical nanomanipulation. The kinetic friction between the nanowires and substrate was determined from the bent shape of the nanowires. The kinetic friction force per unit area, i.e. frictional shear stress, for the ZnO/SiO2 and ZnO/SiN nanowire/substrate systems being measured were 1.05 ± 0.28 and 2.08 ± 0.33 MPa, respectively. The surface roughness and the Hamaker constant of SiO2 and SiN substrates had significant effect on the frictional stresses.

  18. Respiratory performance and grip strength tests in Indian school bodys of different socio-economic status.

    PubMed Central

    De, A. K.; Debnath, P. K.; Dey, N. K.; Nagchaudhuri, J.

    1980-01-01

    Physical efficiency tests were performed on urban school boys drawn from high socio-economic status in comparison to rural school boys. The height and weight records of the subjects indicating growing process showed that the rural boys attained less physical growth than their urban counterparts. The Vital Capacity and Peak Expiratory Flow Rate data expressed either per unit of height or body surface area were significantly lower in rual boys. these findings indicated a poor development of the thorax in the rural group. However, the determined grip strengths for both the group were similar. The grip test might reflect improvement of muscle mass in case of rural boys as a result of regular physical activity employing the arm muscles. Images p145-a p145-b PMID:7407454

  19. Manual actuator. [for spacecraft exercising machines

    NASA Technical Reports Server (NTRS)

    Gause, R. L.; Glenn, C. G. (Inventor)

    1974-01-01

    An actuator for an exercising machine employable by a crewman aboard a manned spacecraft is presented. The actuator is characterized by a force delivery arm projected from a rotary imput shaft of an exercising machine and having a force input handle extended orthogonally from its distal end. The handle includes a hand-grip configured to be received within the palm of the crewman's hand and a grid pivotally supported for angular displacement between a first position, wherein the grid is disposed in an overlying juxtaposition with the hand-grip, and a second position, angularly displaced from the first position, for affording access to the hand-grip, and a latching mechanism fixed to the sole of a shoe worn by the crewman for latching the shoe to the grid when the grid is in the first position.

  20. Grip preference, dermatoglyphics, and hand use in captive chimpanzees (Pan troglodytes).

    PubMed

    Hopkins, William D; Russell, Jamie L; Hostetter, Autumn; Pilcher, Dawn; Dahl, Jeremy F

    2005-09-01

    This paper examined the association between grip type, hand use, and fingerprint patterns in a sample of captive chimpanzees. Grip type for simple reaching was assessed for the left and right hand and classified as thumb-index, middle-index, or single-digit responses. Fingerprint patterns were characterized as whorls, loops, or arches on each finger. The results indicated that chimpanzees exhibit significantly more thumb-index responses for the right compared to the left hand. In addition, thumb-index responses were more prevalent for subjects that had a whorl compared to a loop or arch on their thumb. The results suggest that fingerprint patterns are associated with individual differences in grasping type in chimpanzees as well as some variation in hand use. (c) 2005 Wiley-Liss, Inc.

  1. Does proline isomerization shape the folding funnel of the wild type and mutant staphylococcal nuclease?

    NASA Astrophysics Data System (ADS)

    Tsong, Tian Yow; Su, Zheng-Ding

    1999-10-01

    Cis/trans isomerization of proline residues is known to exhibit high activation energies. These kinetic barriers often dominate the energy landscape of protein folding. There are 6 proline residues (at positions 11, 31, 42, 47, 56 and 117) in staphylococcal nuclease (SNase) [EC 3.1.31.1]. Stopped-flow CD222nm measuring the evolution of the secondary structure of protein has detected 5 kinetic barriers in SNase folding (ΔG≠ for τfr<15, τf1 16.9, τf2 18.5, τf3 19.5, and τfs 21.8 kcal/mol) and 3 kinetic barriers in unfolding (ΔG≠ for τur<15, τu1 17.4, τus 21.6 kcal/mol). To investigate systematically how individual proline residues and 6 proline residues in toto can shape the folding funnel we have expediently constructed 7 proline mutants for study. They are 6 single-proline-substituted mutants (P11A, P31A, P42A, P47A, P56A and P117A) and 1 proline-free mutant (PallA). Study of equilibrium folding/unfolding and stopped-flow kinetics of the wildtype and the 7 mutants of SNase have allowed us to identify sources of 3 main kinetic barriers in the SNase folding. The highest barrier (ΔG≠=21.8 kcal) belongs to the cis/trans isomerization of Pro117. The next barrier (ΔG≠=19.5 kcal) involves synergetic effects of proline residues which limits the rate of folding of the oligonucleotide binding (OB) domain in all 7 proline-containing SNase. For the proline-free mutant (PallA) the OB domain folds rapidly. Furthermore, we have found that the equilibrium folding/unfolding properties of these proline mutants are remarkably similar to that of the wildtype despite their startlingly different folding/unfolding kinetics. These results lead us to conclude that while free energy of folding (ΔGF=-4.5 kcal/mol) provides the driving force, it is the activation energy that forms a conduit or shapes a kinetic funnel for SNase folding. The landscape for SNase folding is extremely rugged. Data support our previously proposed Least Activation Path (LAP) model for protein folding [Su, Z.D. et al. Proc. Natl. Acad. Sci. USA 93, 2539-2544 (1996)]. The LAP concept depicts protein folding as the movement of the unfolded population of protein along deep valleys of the energy landscape to reach the free energy minimum of the native state. An analogy for the LAP model would be flow of water from a highland over the rugged surface of a landscape to reach the lowest point of the ground. The fine features of the landscape will dictate kinetics and pathways of the flow.

  2. High-temperature morphological evolution of lithographically introduced cavities in silicon carbide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narushima, Takayuki; Glaeser, Andreas M.

    2000-12-01

    Internal cavities of controlled geometry and crystallography were introduced in 6H silicon carbide single crystals by combining lithographic methods, ion beam etching, and solid-state diffusion bonding. The morphological evolution of these internal cavities (negative crystals) in response to anneals of up to 128 h duration at 1900 degrees C was examined using optical microscopy. Surface energy anisotropy and faceting have a strong influence on both the geometric and kinetic characteristics of evolution. Decomposition of 12{bar 1}0 cavity edges into 101{bar 0} facets was observed after 16 h anneals, indicating that 12{bar 1}0 faces are not components of the Wulff shape.more » The shape evolution kinetics of penny-shaped cavities were also investigated. Experimentally observed evolution rates decreased much more rapidly with those predicted by a model in which surface diffusion is assumed to be rate-limiting. This suggests that the development of facets, and the associated loss of ledges and terraces during the initial stages of evolution results in an evolution process limited by the nucleation rate of attachment/detachment sites (ledges) on the facets.« less

  3. A D-Shaped Bileaflet Bioprosthesis which Replicates Physiological Left Ventricular Flow Patterns

    PubMed Central

    Tan, Sean Guo-Dong; Kim, Sangho; Hon, Jimmy Kim Fatt; Leo, Hwa Liang

    2016-01-01

    Prior studies have shown that in a healthy heart, there exist a large asymmetric vortex structure that aids in establishing a steady flow field in the left ventricle. However, the implantation of existing artificial heart valves at the mitral position is found to have a negative effect on this physiological flow pattern. In light of this, a novel D-shaped bileaflet porcine bioprosthesis (GD valve) has been designed based on the native geometry mitral valve, with the hypothesis that biomimicry in valve design can restore physiological left ventricle flow patterns after valve implantation. An in-vitro experiment using two dimensional particle velocimetry imaging was carried out to determine the hemodynamic performance of the new bileaflet design and then compared to that of the well-established St. Jude Epic valve which functioned as a control in the experiment. Although both valves were found to have similar Reynolds shear stress and Turbulent Kinetic Energy levels, the novel D-shape valve was found to have lower turbulence intensity and greater mean kinetic energy conservation. PMID:27258099

  4. Prediction of precipitate evolution and martensite transformation in Ti-Ni-Cu shape memory alloys by computational thermodynamics

    NASA Astrophysics Data System (ADS)

    Povoden-Karadeniz, A.; Cirstea, D. C.; Kozeschnik, E.

    2016-04-01

    Ti-50Ni to Ti-55Ni (at.%) can be termed as the pioneer of shape memory alloys (SMA). Intermetallic precipitates play an important role for strengthening. Their influence on the start temperature of the martensitic transformation is a crucial property for the shape memory effect. Efforts for increasing the martensite start temperature include replacement of a part of Ni atoms by Cu. The influence of Cu-addition to Ti-Ni SMA on T0- temperatures and the character of the austenite-martensite transformation is evaluated using a new thermodynamic database for the Ti-Ni-system extended by Cu. Trends of precipitation of intermetallic phases are simulated by combining the assessed thermodynamics of the Ti-Ni-Cu system with assessed diffusion mobility data and kinetic models, as implemented in the solid-state transformation software MatCalc and are presented in the form of time-temperature-precipitation diagrams. Thermodynamic equilibrium considerations, complemented by predictive thermo-kinetic precipitation simulation, facilitates SMA alloy design and definition of optimized aging conditions.

  5. Thermoluminescence kinetic features of Lithium Iodide (LiI) single crystal grown by vertical Bridgman technique

    NASA Astrophysics Data System (ADS)

    Daniel, D. Joseph; Kim, H. J.; Kim, Sunghwan; Khan, Sajid

    2017-08-01

    Single crystal of pure Lithium Iodide (LiI) has been grown from melt by using the vertical Bridgman technique. Thermoluminescence (TL) Measurements were carried out at 1 K/s following X-ray irradiation. The TL glow curve consists of a dominant peak at (peak-maximum Tm) 393 K and one low temperature peak of weaker intensity at 343 K. The order of kinetics (b), activation energy (E), and the frequency factor (S) for a prominent TL glow peak observed around 393 K for LiI crystals are reported for the first time. The peak shape analysis of the glow peak indicates the kinetics to be of the first order. The value of E is calculated using various standard methods such as initial rise (IR), whole glow peak (WGP), peak shape (PS), computerized glow curve deconvolution (CGCD) and Variable Heating rate (VHR) methods. An average value of 1.06 eV is obtained in this case. In order to validate the obtained parameters, numerically integrated TL glow curve has been generated using experimentally determined kinetic parameters. The effective atomic number (Zeff) for this material was determined and found to be 52. X-ray induced emission spectra of pure LiI single crystal are studied at room temperature and it is found that the sample exhibit sharp emission at 457 nm and broad emission at 650 nm.

  6. Dissolution Kinetics of Spheroidal-Shaped Precipitates in Age-Hardenable Aluminum Alloys

    NASA Astrophysics Data System (ADS)

    Anjabin, Nozar; Salehi, Majid Seyed

    2018-05-01

    As a first attempt, a mathematical model is proposed to predict the dissolution kinetics of non-spherical secondary phase precipitates during solution heat treatment of age-hardenable aluminum alloys. The model uses general spheroidal geometry to describe the dissolution process of the alloys containing needle/disc-shaped particles with different size distributions in a finite matrix. It is found that as the aspect ratio deviates from unity, the dissolution rate is accelerated. Also, the dissolution rate of the particles in the alloy containing the particle size distribution is lower than that of mono-sized particles system. The modeling results for dissolution of θ' precipitates in an Al-Cu alloy are compared with experiments, and a good agreement was found between the modeling and the experimental results. The proposed model can be applied to different isothermal and non-isothermal annealing conditions.

  7. Engineering of Organic Nanocrystals by Electrocrystallization

    NASA Astrophysics Data System (ADS)

    Kilani, Mohamed

    This work discusses the experimental and theoretical methods used to control the morphology of nanocrystals. The hypothesis of the thermodynamic/kinetic control of the morphology was verified. We applied the electrocrystallization to make K(def)TCP nanocrystals and we tuned the electrochemical parameters to determine their influence on the nanocrystals morphologies. The characterization was mainly performed with AFM and FE-SEM. We presented in this work the possibility to control the morphology of K(def)TCP using the electrochemical parameters. The obtained shapes ranged from nanorods to rhombohedral shape, which is reported for the first time. The observed growth behavior was modeled and simulated with a method based on Monte-Carlo techniques. The simulation results show a qualitative match with the experimental findings. This work contributes to the understanding of the crystal growth behavior and the thermodynamic/kinetic morphology transition using electrocrystallization.

  8. GRIP Experiment 2010

    NASA Image and Video Library

    2010-08-16

    Cloud formations are seen through the window of NASA DC-8 aircraft during a flight, Tuesday, Aug. 17, 2010, over the Gulf of Mexico where researchers were studying weather patterns as part of trhe Genesis and Rapid Intensification Processes (GRIP) experiment, a NASA Earth science field experiment in 2010 that is being conducted to better understand how tropical storms form and develop into major hurricanes. Photo Credit: (NASA/Paul E. Alers)

  9. The Effect of Repetitive Rhythmic Precision Grip Task-Oriented Rehabilitation in Chronic Stroke Patients: A Pilot Study

    ERIC Educational Resources Information Center

    Dispa, Delphine; Lejeune, Thierry; Thonnard, Jean-Louis

    2013-01-01

    Most chronic stroke patients present with difficulty in the manipulation of objects. The aim of this study was to test whether an intensive program of precision grip training could improve hand functioning of patients at more than 6 months after a stroke. This was a cross-over study; hence, at inclusion, the patients were randomly divided into two…

  10. Transcranial direct current stimulation over multiple days enhances motor performance of a grip task.

    PubMed

    Fan, Julie; Voisin, Julien; Milot, Marie-Hélène; Higgins, Johanne; Boudrias, Marie-Hélène

    2017-09-01

    Recovery of handgrip is critical after stroke since it is positively related to upper limb function. To boost motor recovery, transcranial direct current stimulation (tDCS) is a promising, non-invasive brain stimulation technique for the rehabilitation of persons with stroke. When applied over the primary motor cortex (M1), tDCS has been shown to modulate neural processes involved in motor learning. However, no studies have looked at the impact of tDCS on the learning of a grip task in both stroke and healthy individuals. To assess the use of tDCS over multiple days to promote motor learning of a grip task using a learning paradigm involving a speed-accuracy tradeoff in healthy individuals. In a double-blinded experiment, 30 right-handed subjects (mean age: 22.1±3.3 years) participated in the study and were randomly assigned to an anodal (n=15) or sham (n=15) stimulation group. First, subjects performed the grip task with their dominant hand while following the pace of a metronome. Afterwards, subjects trained on the task, at their own pace, over 5 consecutive days while receiving sham or anodal tDCS over M1. After training, subjects performed de novo the metronome-assisted task. The change in performance between the pre and post metronome-assisted task was used to assess the impact of the grip task and tDCS on learning. Anodal tDCS over M1 had a significant effect on the speed-accuracy tradeoff function. The anodal tDCS group showed significantly greater improvement in performance (39.28±15.92%) than the sham tDCS group (24.06±16.35%) on the metronome-assisted task, t(28)=2.583, P=0.015 (effect size d=0.94). Anodal tDCS is effective in promoting grip motor learning in healthy individuals. Further studies are warranted to test its potential use for the rehabilitation of fine motor skills in stroke patients. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Relationship between muscle strength and dyslipidemia, serum 25(OH)D, and weight status among diverse schoolchildren: a cross-sectional analysis.

    PubMed

    Blakeley, Caitlin E; Van Rompay, Maria I; Schultz, Nicole S; Sacheck, Jennifer M

    2018-02-02

    The relationship between muscle strength and cardiometabolic risk factors in youth, and the potential influence of vitamin D status on this relationship, is not well understood. This study examined associations between muscle strength and dyslipidemia, serum 25-hydroxyvitamin D [25(OH)D], and weight status in diverse schoolchildren. Measures of hand-grip strength (standardized for sex and body weight), anthropometrics (height and weight converted to BMI z-score [BMIz]), sociodemographics, and fasting blood concentrations of plasma HDL-C and triglycerides and serum 25(OH)D were collected from 350 4th-8th grade schoolchildren (11.2 ± 1.3 y, 49.4% female, 56.3% non-white/Caucasian). Logistic regression was used to measure associations between standardized tertiles of grip strength and blood lipids, 25(OH)D, and weight status along with associations between 25(OH)D and dyslipidemia and weight status. Children with higher grip strength had lower odds of overweight/obesity (OR: 0.03, 95% CI: 0.01-0.06, in the highest tertile of grip strength vs. lowest, p for trend< 0.0001), borderline/low HDL-C (OR: 0.28, 95% CI: 0.16-0.50, p for trend< 0.0001), and borderline/high triglycerides (OR: 0.48, 95% CI: 0.25-0.92, p for trend< 0.05), adjusting for covariates. Associations between blood lipids and grip strength became non-significant after further adjustment for BMIz. No association was observed between grip strength and 25(OH)D, nor between 25(OH)D and borderline/low HDL-C or weight status; however, vitamin D sufficiency was associated with lower odds of borderline/high triglycerides compared with vitamin D deficiency (OR: 0.26, 95% CI: 0.09-0.74, p for trend< 0.05) before BMIz adjustment. Among racially/ethnically diverse children, muscle strength was associated with lower dyslipidemia. Longitudinal studies are needed to explore whether changes in muscle strength impact this relationship in children, independent of weight status. This study was registered at www.clinicaltrials.gov (No. NCT01537809 ) on February 17, 2012.

  12. Professional Development for Graduate Students through Internships at Federal Labs: an NSF/USGS Collaboration

    NASA Astrophysics Data System (ADS)

    Snow, E.; Jones, E.; Patino, L. C.; Wasserman, E.; Isern, A. R.; Davies, T.

    2016-12-01

    In 2013 the White House initiated an effort to coordinate STEM education initiatives across federal agencies. This idea spawned several important collaborations, one of which is a set of National Science Foundation programs designed to place graduate students in federal labs for 2-12 months of their Ph.D. training. The Graduate Research Internship Program (GRIP) and the Graduate Student Preparedness program (GSP) each have the goal of exposing PhD students to the federal work environment while expanding their research tools and mentoring networks. Students apply for supplementary support to their Graduate Research Fellowship (GRIP) or their advisor's NSF award (GSP). These programs are available at several federal agencies; the USGS is one partner. At the U.S. Geological Survey, scientists propose projects, which students can find online by searching USGS GRIP, or students and USGS scientists can work together to develop a research project. At NSF, projects are evaluated on both the scientific merit and the professional development opportunities they afford the student. The career development extends beyond the science (new techniques, data, mentors) into the professional activity of writing the proposal, managing the budget, and working in a new and different environment. The USGS currently has 18 GRIP scholars, including Madeline Foster-Martinez, a UC Berkeley student who spent her summer as a GRIP fellow at the USGS Pacific Coastal and Marine Science Center working with USGS scientist Jessica Lacy. Madeline's Ph.D. work is on salt marshes and she has studied geomorphology, accretion, and gas transport using a variety of research methods. Her GRIP fellowship allowed her to apply new data-gathering tools to the question of sediment delivery to the marsh, and build and test a model for sediment delivery along marsh edges. In addition, she gained professional skills by collaborating with a new team of scientists, running a large-scale field deployment, and experiencing a new work environment. The program is succeeding in mentoring the next generation of geoscientists. At the USGS, we hope that some of these scientists will look for their first full-time job here.

  13. Muscle strength and body composition are clinical indicators of osteoporosis.

    PubMed

    Rikkonen, Toni; Sirola, Joonas; Salovaara, Kari; Tuppurainen, Marjo; Jurvelin, Jukka S; Honkanen, Risto; Kröger, Heikki

    2012-08-01

    We examined the role of muscle strength, lean tissue distribution, and overall body composition as indicators of osteoporosis (OP) in a pooled sample of 979 Finnish postmenopausal women (mean age 68.1 years) from the Kuopio Osteoporosis Risk Factor and Prevention study. Bone mineral density (BMD) at the femoral neck (FN) and total body composition were assessed by dual-energy X-ray absorptiometry scans. The women (n = 979) were divided into three groups according to WHO criteria, based on FN BMD T score: normal (n = 474), osteopenia (n = 468), and OP (n = 37). Soft tissue proportions, fat mass index (FMI, fat/height²), lean mass index (LMI, lean/height²), and appendicular skeletal muscle mass (ASM, (arms + legs)/height²) were calculated. Handgrip and knee extension strength measurements were made. OP subjects had significantly smaller LMI (p = 0.001), ASM (p = 0.001), grip strength (p < 0.0001), and knee extension strength (p < 0.05) but not FMI (p > 0.05) compared to other subjects. Grip and knee extension strength were 19 and 16 % weaker in OP women compared to others, respectively. The area under the receiver operating characteristic curve was 69 % for grip and 71 % for knee extension strength. In tissue proportions only LMI showed predictive power (63 %, p = 0.016). An overall linear association of LMI (R² = 0.007, p = 0.01) and FMI (R² = 0.028, p < 0.001) with FN BMD remained significant. In the multivariate model, after adjusting for age, grip strength, leg extension strength, FMI, LMI, number of medications, alcohol consumption, current smoking, dietary calcium intake, and hormone therapy, grip strength (adjusted OR = 0.899, 95 % CI 0.84-0.97, p < 0.01), leg extension strength (OR = 0.998, 95 % CI 0.99-1, p < 0.05), and years of hormone therapy (OR = 0.905, 95 % CI 0.82-1, p < 0.05) remained as significant determinants of OP. Muscle strength tests, especially grip strength, serve as an independent and useful tool for postmenopausal OP risk assessment. In addition, lean mass contributes to OP in this age group. Muscle strength and lean mass should be considered separately since both are independently associated with postmenopausal BMD.

  14. Does Kinesiotaping improve pain and functionality in patients with newly diagnosed lateral epicondylitis?

    PubMed

    Eraslan, Leyla; Yuce, Deniz; Erbilici, Arzu; Baltaci, Gul

    2018-03-01

    This study aimed to compare the short-term effects of kinesiotaping and extracorporeal shock wave therapy (ESWT) along with physiotherapy on pain, functionality, and grip strength in patients with newly diagnosed lateral epicondylitis undergoing rehabilitation. Forty-five voluntary patients (mean age 48 years) were randomly assigned to three groups. Patients in all groups received physiotherapy consisting of a cold pack and transcutaneous electrical nerve stimulation five times per week for a total of 15 sessions and a home exercise programme including stretching and eccentric strength exercises. In the second group, patients received kinesiotaping 5 days a week for 3 weeks. In the third group, ESWT was applied three times for 3 weeks. Patients were assessed by visual analogue scale for pain intensity, pain-free grip strength using a hand dynamometer, Cyriax Resisted Muscle Test, and Patient-Rated Tennis Elbow Evaluation Scale. All measurements were collected at baseline and after treatment. There were no significant differences in the demographic characteristics of the patients in all groups at baseline. Intra-group analysis revealed that pain intensity decreased, whereas maximum grip strength and functionality increased in all groups at the end of the treatment (p < 0.05). Inter-group analysis revealed that the kinesiotaping group yielded better results in decreasing pain intensity than the other groups (p < 0.05). The kinesiotaping group (p < 0.001) and ESWT group (p = 0.002) yielded better results in improving functionality than the physiotherapy group. There were significant differences in recovering pain-free grip strength in the kinesiotaping group (p < 0.05). Kinesiotaping was found to be effective for decreasing pain intensity, recovering grip strength, and improving functionality in patients with lateral epicondylitis undergoing rehabilitation. Therapeutic study, Level II.

  15. Association of physical performance measures with bone mineral density in postmenopausal women.

    PubMed

    Lindsey, Carleen; Brownbill, Rhonda A; Bohannon, Richard A; Ilich, Jasminka Z

    2005-06-01

    To investigate the association between physical performance measures and bone mineral density (BMD) in older women. Cross-sectional analysis. University research laboratory. Healthy postmenopausal women (N=116; mean age +/- standard deviation, 68.3+/-6.8y) in self-reported good health who were not taking medications known to affect bone, including hormone replacement therapy. Not applicable. Anthropometrics and BMD of the hip, spine, whole body, and forearm. Physical performance measures included normal and brisk 8-m gait speed, normal step length (NSL), brisk step length (BSL), timed 1-leg stance (OLS), timed sit-to-stand (STS), and grip strength. NSL, BSL, normal gait speed, brisk gait speed, OLS, and grip strength correlated significantly with several skeletal sites ( r range, .19-.38; P <.05). In multiple regression models containing body mass index, hours of total activity, total calcium intake, and age of menarche, NSL, BSL, normal and brisk gait speeds, OLS, and grip strength were all significantly associated with BMD of various skeletal sites (adjusted R 2 range, .11-.24; P <.05). Analysis of covariance showed that subjects with longer step lengths and faster normal and brisk gait speeds had higher BMD at the whole body, hip, and spine (brisk speed only). Those with a longer OLS had greater femoral neck BMD, and those with a stronger grip strength had greater BMD in the whole body and forearm ( P <.05). STS was not related to any skeletal site. Normal and brisk gait speed, NSL, BSL, OLS, and grip strength are all associated with BMD at the whole body, hip, spine, and forearm. Physical performance evaluation may help with osteoporosis prevention and treatment programs for postmenopausal women when bone density scores have not been obtained or are unavailable.

  16. Relationship among maximal grip, throwing velocity and anthropometric parameters in elite water polo players.

    PubMed

    Ferragut, C; Vila, H; Abraldes, J A; Argudo, F; Rodriguez, N; Alcaraz, P E

    2011-03-01

    As independent aspects, body size, body composition, and physiological performance of elite athletes have aroused the interest of sports scientists but, unfortunately, studies that combine these aspects are scarcely avalaible in water polo. The aim of the present study was to: 1) to develop an anthropometric profile of highly skilled male Water Polo players, and 2) to identify significant relationships between these features and overhead throwing velocity in highly skilled male water polo players. Thirteen male water polo players, with a mean age of 26.10±4.82, were recruited from the Spanish Water Polo team and an anthropometric assessment on all of them was carried out. Throwing velocity was evaluated in three different situations from the 5 m-penalty line on the center of the water polo goal: A) throwing without a defender nor a goalkeeper; B) throwing with a goalkeeper only, and C) 3) armfuls running shot with goalkeeper. Maximal handgrip was also tested. Biacromial breadth shows a significative correlation with hand grip in water polo players (r=0.792; P=0.001) and also correlates with Throwing velocity (r=0.716; P<0.001). Biepicondylar femur breadth correlates significatively with hand grip (r=0.727; P<0.05) and also with throwing velocity in "throwing with goalkeeper" situation (r=0.664; P<0.05). Hand grip shows a significant correlation with throwing velocity in "throwing with goalkeeper" situation (r=0.603; P<0.05). In conclusion, body mass aspects are not related with throwing velocity in highly skilled Water Polo players. Maximal hand grip is related with throwing velocity in "throwing with goalkeeper" situation. More investigations about water polo are necessary.

  17. Key Insights into Hand Biomechanics: Human Grip Stiffness Can Be Decoupled from Force by Cocontraction and Predicted from Electromyography

    PubMed Central

    Höppner, Hannes; Große-Dunker, Maximilian; Stillfried, Georg; Bayer, Justin; van der Smagt, Patrick

    2017-01-01

    We investigate the relation between grip force and grip stiffness for the human hand with and without voluntary cocontraction. Apart from gaining biomechanical insight, this issue is particularly relevant for variable-stiffness robotic systems, which can independently control the two parameters, but for which no clear methods exist to design or efficiently exploit them. Subjects were asked in one task to produce different levels of force, and stiffness was measured. As expected, this task reveals a linear coupling between force and stiffness. In a second task, subjects were then asked to additionally decouple stiffness from force at these force levels by using cocontraction. We measured the electromyogram from relevant groups of muscles and analyzed the possibility to predict stiffness and force. Optical tracking was used for avoiding wrist movements. We found that subjects were able to decouple grip stiffness from force when using cocontraction on average by about 20% of the maximum measured stiffness over all force levels, while this ability increased with the applied force. This result contradicts the force–stiffness behavior of most variable-stiffness actuators. Moreover, we found the thumb to be on average twice as stiff as the index finger and discovered that intrinsic hand muscles predominate our prediction of stiffness, but not of force. EMG activity and grip force allowed to explain 72 ± 12% of the measured variance in stiffness by simple linear regression, while only 33 ± 18% variance in force. Conclusively the high signal-to-noise ratio and the high correlation to stiffness of these muscles allow for a robust and reliable regression of stiffness, which can be used to continuously teleoperate compliance of modern robotic hands. PMID:28588472

  18. Sensorimotor dysfunction of grasping in schizophrenia: a side effect of antipsychotic treatment?

    PubMed Central

    Nowak, D A; Connemann, B J; Alan, M; Spitzer, M

    2006-01-01

    Background Antipsychotic treatment in schizophrenia is frequently associated with extrapyramidal side effects. Objective behavioural measures to evaluate the severity of extrapyramidal side effects in the clinical setting do not exist. Objectives This study was designed to investigate grasping movements in five drug naive and 13 medicated subjects with schizophrenia and to compare their performance with that of 18 healthy control subjects. Deficits of grip force performance were correlated with clinical scores of both parkinson‐like motor disability and psychiatric symptom severity Methods Participants performed vertical arm movements with a handheld instrumented object and caught a weight that was dropped into a handheld cup either expectedly from the opposite hand or unexpectedly from the experimenter's hand. The scaling of grip force and the temporospatial coupling between grip and load force profiles was analysed. The psychiatric symptom severity was assessed by the positive and negative symptom score of schizophrenia and the brief psychiatric rating scale. Extrapyramidal symptoms were assessed by the unified Parkinson's disease rating scale. Results Drug naive subjects with schizophrenia performed similar to healthy controls. In contrast, medicated subjects with schizophrenia exhibited excessive grip force scaling and impaired coupling between grip and load force profiles. These performance deficits were strongly correlated with the severity of both extrapyramidal side effects related to antipsychotic therapy and negative symptoms related to the underlying pathology. Conclusions These data provide preliminary evidence that deficits of sensorimotor performance in schizophrenia are, at least in part, related to the side effects of antipsychotic treatment. The investigation of grasping movements may provide a sensitive measure to objectively evaluate extrapyramidal side effects related to antipsychotic therapy. PMID:16614027

  19. Heterogeneity in Rate of Decline in Grip, Hip, and Knee Strength and the Risk of All-Cause Mortality: The Women’s Health and Aging Study II

    PubMed Central

    Xue, Qian-Li; Beamer, Brock A.; Chaves, Paulo H.M.; Guralnik, Jack M.; Fried, Linda P.

    2010-01-01

    OBJECTIVES To assess the relationship between rate of change in muscle strength and all-cause mortality. DESIGN A prospective observational study of the causes and course of physical disability. SETTING Twelve contiguous ZIP code areas in Baltimore, Maryland. PARTICIPANTS Three hundred and seven community-dwelling women aged 70–79 years at study baseline. MEASUREMENTS The outcome is all-cause mortality (1994–2009); predictors include up to seven repeated measurements of handgrip, knee extension, and hip flexion strength, with a median follow-up time of 9 years. Demographic factors, body mass index, smoking status, number of chronic diseases, depressive symptoms, physical activity, Interlukin-6, and albumin were assessed at baseline and included as confounders. The associations between declining muscle strength and mortality were assessed using a joint longitudinal and survival model.. RESULTS Grip and hip strength declined an average of 1.10 and 1.31 kg per year between age 70 and 75and 0.50 and 0.39 kg/year thereafter, respectively; knee strength declined at a constant rate of 0.57 kg/year. Faster rates of decline in grip and hip strength, but not knee strength, independently predicted of mortality after accounting for their baseline levels and potential confounders (Hazard Ratio (HR)=1.33 (95% confidence interval (CI)=1.06–1.67), 1.14 (CI=0.91–1.41), and 2.62 (CI=1.43–4.78) for every 0.5 standard deviation increase in rate of decline in grip, knee, and hip strength, respectively. CONCLUSION Monitoring the rate of decline in grip and hip flexion strength in addition to the absolute levels may greatly improve the identification of women most at risk of dying. PMID:21054287

  20. Differences in musculoskeletal health due to gender in a rural multiethnic cohort: a Project FRONTIER study.

    PubMed

    Brismée, J M; Yang, S; Lambert, M E; Chyu, M C; Tsai, P; Zhang, Y; Han, J; Hudson, C; Chung, Eunhee; Shen, C L

    2016-04-26

    Very few studies have investigated differences in musculoskeletal health due to gender in a large rural population. The aim of this study is to investigate factors affecting musculoskeletal health in terms of hand grip strength, musculoskeletal discomfort, and gait disturbance in a rural-dwelling, multi-ethnic cohort. Data for 1117 participants (40 years and older, 70% female) of an ongoing rural healthcare study, Project FRONTIER, were analyzed. Subjects with a history of neurological disease, stroke and movement disorder were excluded. Dominant hand grip strength was assessed by dynamometry. Gait disturbance including stiff, spastic, narrow-based, wide-based, unstable or shuffling gait was rated. Musculoskeletal discomfort was assessed by self-reported survey. Data were analyzed by linear, logistic regression and negative binomial regressions as appropriate. Demographic and socioeconomic factors were adjusted in the multiple variable analyses. In both genders, advanced age was a risk factor for weaker hand grip strength; arthritis was positively associated with musculoskeletal discomfort, and fair or poor health was significantly associated with increased risk of gait disturbance. Greater waist circumference was associated with greater musculoskeletal discomfort in males only. In females, advanced age is the risk factor for musculoskeletal discomfort as well as gait disturbance. Females with fair or poor health had weaker hand grip strength. Higher C-reactive protein and HbA1c levels were also positively associated with gait disturbance in females, but not in males. This cross-sectional study demonstrates how gender affects hand grip strength, musculoskeletal discomfort, and gait in a rural-dwelling multi-ethnic cohort. Our results suggest that musculoskeletal health may need to be assessed differently between males and females.

Top