Lee, Ju-Yeun; Bae, Kunho; Park, Kyung-Ah; Lyu, In Jeong; Oh, Sei Yeul
2016-01-01
The aim of this study was to investigate extraocular muscle (EOM) volume and cross-sectional area using computed tomography (CT), and to determine the relationship between EOM size and the vertical angle of deviation in thyroid eye disease (TED). Twenty-nine TED patients (58 orbits) with vertical strabismus were enrolled in the study. All patients underwent complete ophthalmic examination including prism, alternate cover, and Krimsky tests. Orbital CT scans were also performed on each patient. Digital image analysis was used to quantify superior rectus (SR) and inferior rectus (IR) muscle cross-sectional areas and volumes. Measurements were compared with those of controls. The correlation between muscle size and degree of vertical angle deviation was evaluated. The mean vertical angle of deviation was 26.2 ± 4.1 prism diopters. The TED group had a greater maximum cross-sectional area and EOM volume in the SR and IR than the control group (all p<0.001). Area and volume of the IR were correlated with the angle of deviation, but the SR alone did not show a significant correlation. The maximum cross-sectional area and volume of [Right IR + Left SR − Right SR − Left IR] was strongly correlated with the vertical angle of deviation (P<0.001). Quantitative CT of the orbit with evaluation of the area and volume of EOMs may be helpful in anticipating and monitoring vertical strabismus in TED patients. PMID:26820406
Lee, Ju-Yeun; Bae, Kunho; Park, Kyung-Ah; Lyu, In Jeong; Oh, Sei Yeul
2016-01-01
The aim of this study was to investigate extraocular muscle (EOM) volume and cross-sectional area using computed tomography (CT), and to determine the relationship between EOM size and the vertical angle of deviation in thyroid eye disease (TED). Twenty-nine TED patients (58 orbits) with vertical strabismus were enrolled in the study. All patients underwent complete ophthalmic examination including prism, alternate cover, and Krimsky tests. Orbital CT scans were also performed on each patient. Digital image analysis was used to quantify superior rectus (SR) and inferior rectus (IR) muscle cross-sectional areas and volumes. Measurements were compared with those of controls. The correlation between muscle size and degree of vertical angle deviation was evaluated. The mean vertical angle of deviation was 26.2 ± 4.1 prism diopters. The TED group had a greater maximum cross-sectional area and EOM volume in the SR and IR than the control group (all p<0.001). Area and volume of the IR were correlated with the angle of deviation, but the SR alone did not show a significant correlation. The maximum cross-sectional area and volume of [Right IR + Left SR - Right SR - Left IR] was strongly correlated with the vertical angle of deviation (P<0.001). Quantitative CT of the orbit with evaluation of the area and volume of EOMs may be helpful in anticipating and monitoring vertical strabismus in TED patients.
Descriptive Statistics and Cluster Analysis for Extreme Rainfall in Java Island
NASA Astrophysics Data System (ADS)
E Komalasari, K.; Pawitan, H.; Faqih, A.
2017-03-01
This study aims to describe regional pattern of extreme rainfall based on maximum daily rainfall for period 1983 to 2012 in Java Island. Descriptive statistics analysis was performed to obtain centralization, variation and distribution of maximum precipitation data. Mean and median are utilized to measure central tendency data while Inter Quartile Range (IQR) and standard deviation are utilized to measure variation of data. In addition, skewness and kurtosis used to obtain shape the distribution of rainfall data. Cluster analysis using squared euclidean distance and ward method is applied to perform regional grouping. Result of this study show that mean (average) of maximum daily rainfall in Java Region during period 1983-2012 is around 80-181mm with median between 75-160mm and standard deviation between 17 to 82. Cluster analysis produces four clusters and show that western area of Java tent to have a higher annual maxima of daily rainfall than northern area, and have more variety of annual maximum value.
Lee, Haeng-Jin; Kim, Seong-Joon; Yu, Young Suk
2018-06-18
To evaluate long-term outcomes of homogenous bilateral rectus recession in patients with the same preoperative angle of deviation in intermittent exotropia and investigate factors associated with surgical outcomes. In this retrospective review, patients with the same preoperative angle of deviation who underwent bilateral 6-mm lateral rectus recession between January 2008 and January 2014 were observed for 2 or more years. Patients were classified into two groups based on deviation angle: success (orthophoria or exodeviation < 10 prism diopters [PD]) or recurrence (exodeviation ≥ 10 PD). Preoperative and postoperative ophthalmologic factors were compared between groups. The success and recurrence groups contained 50 and 49 patients, respectively. Preoperative maximum angle of deviation was 29.0 ± 1.8 PD at distance in the success group and 28.9 ± 1.8 PD in the recurrence group. Deviation at the 2-year follow-up was 3.7 ± 3.7 and 18.3 ± 5.3 PD in the success and recurrence groups, respectively (P < .001). Preoperative factors were not significantly different between groups except for presence of lateral incomitance; success group patients presented more lateral incomitance (P = .035). The success group also presented more esodeviation just after the operation and showed a more stable course during follow-up. Surgical outcomes of patients with 10 PD or more of esodeviation 1 week postoperatively were significantly more favorable than patients with less than 10 PD of esodeviation (P = .027, log-rank test). Presence of lateral incomitance and early postoperative overcorrection were significantly associated with favorable surgical outcome and should be considered when planning intermittent exotropia surgery. [J Pediatr Ophthalmol Strabismus. 201X;XX(X):XXXX.]. Copyright 2018, SLACK Incorporated.
A randomized intervention trial to reduce mechanical exposures in the Colombian flower industry.
Barrero, L H; Ceballos, C; Ellegast, R; Pulido, J A; Monroy, M; Berrio, S; Quintana, L A
2012-01-01
Evidence on the effectiveness of ergonomic interventions to reduce mechanical demands and upper-extremity MSDs is scarce in agriculture. We conducted an intervention to reduce mechanical exposures during manual flower cutting through job rotation, education and reduction of force requirements. One-hundred and twenty workers (20 to 60 years old; 89% women) from six companies that cultivate roses participated in this study. Three companies were randomly assigned to control and intervention groups. We studied changes between baseline and follow-up in self-reported effort and upper-extremity postures, kinematics and muscular activity. Most of the observed changes were moderate for both groups. The intervention group showed differential improvements compared to the control group for the maximum wrist radial deviation and forearm pronation, and acceleration of the forearm supination-pronation and elbow flexion-extension; and the muscular activity of the flexor and extensor carpi radialis and the flexor carpi ulnaris. However, we also observed that the maximum ulnar deviation, velocity of the wrist flexion-extension and muscular activity of the extensor carpi ulnaris improved more in the control group. These mixed results may be related to limited time for intervention adjustment, and uncontrolled task changes in the control group. Future research should address these issues and test other solutions.
Ding, Yao; Mohamed, Abdallah S R; Yang, Jinzhong; Colen, Rivka R; Frank, Steven J; Wang, Jihong; Wassal, Eslam Y; Wang, Wenjie; Kantor, Michael E; Balter, Peter A; Rosenthal, David I; Lai, Stephen Y; Hazle, John D; Fuller, Clifton D
2015-01-01
The purpose of this study was to investigate the potential of a head and neck magnetic resonance simulation and immobilization protocol on reducing motion-induced artifacts and improving positional variance for radiation therapy applications. Two groups (group 1, 17 patients; group 2, 14 patients) of patients with head and neck cancer were included under a prospective, institutional review board-approved protocol and signed informed consent. A 3.0-T magnetic resonance imaging (MRI) scanner was used for anatomic and dynamic contrast-enhanced acquisitions with standard diagnostic MRI setup for group 1 and radiation therapy immobilization devices for group 2 patients. The impact of magnetic resonance simulation/immobilization was evaluated qualitatively by 2 observers in terms of motion artifacts and positional reproducibility and quantitatively using 3-dimensional deformable registration to track intrascan maximum motion displacement of voxels inside 7 manually segmented regions of interest. The image quality of group 2 (29 examinations) was significantly better than that of group 1 (50 examinations) as rated by both observers in terms of motion minimization and imaging reproducibility (P < .0001). The greatest average maximum displacement was at the region of the larynx in the posterior direction for patients in group 1 (17 mm; standard deviation, 8.6 mm), whereas the smallest average maximum displacement was at the region of the posterior fossa in the superior direction for patients in group 2 (0.4 mm; standard deviation, 0.18 mm). Compared with group 1, maximum regional motion was reduced in group 2 patients in the oral cavity, floor of mouth, oropharynx, and larynx regions; however, the motion reduction reached statistical significance only in the regions of the oral cavity and floor of mouth (P < .0001). The image quality of head and neck MRI in terms of motion-related artifacts and positional reproducibility was greatly improved by use of radiation therapy immobilization devices. Consequently, immobilization with external and intraoral fixation in MRI examinations is required for radiation therapy application. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Flügge, Tabea V; Schlager, Stefan; Nelson, Katja; Nahles, Susanne; Metzger, Marc C
2013-09-01
Digital impression devices are used alternatively to conventional impression techniques and materials. The aims of this study were to evaluate the precision of digital intraoral scanning under clinical conditions (iTero; Align Technologies, San Jose, Calif) and to compare it with the precision of extraoral digitization. One patient received 10 full-arch intraoral scans with the iTero and conventional impressions with a polyether impression material (Impregum Penta; 3M ESPE, Seefeld, Germany). Stone cast models manufactured from the impressions were digitized 10 times with an extraoral scanner (D250; 3Shape, Copenhagen, Denmark) and 10 times with the iTero. Virtual models provided by each method were roughly aligned, and the model edges were trimmed with cutting planes to create common borders (Rapidform XOR; Inus Technologies, Seoul, Korea). A second model alignment was then performed along the closest distances of the surfaces (Artec Studio software; Artec Group, Luxembourg, Luxembourg). To assess precision, deviations between corresponding models were compared. Repeated intraoral scanning was evaluated in group 1, repeated extraoral model scanning with the iTero was assessed in group 2, and repeated model scanning with the D250 was assessed in group 3. Deviations between models were measured and expressed as maximums, means, medians, and root mean square errors for quantitative analysis. Color-coded displays of the deviations allowed qualitative visualization of the deviations. The greatest deviations and therefore the lowest precision were in group 1, with mean deviations of 50 μm, median deviations of 37 μm, and root mean square errors of 73 μm. Group 2 showed a higher precision, with mean deviations of 25 μm, median deviations of 18 μm, and root mean square errors of 51 μm. Scanning with the D250 had the highest precision, with mean deviations of 10 μm, median deviations of 5 μm, and root mean square errors of 20 μm. Intraoral and extraoral scanning with the iTero resulted in deviations at the facial surfaces of the anterior teeth and the buccal molar surfaces. Scanning with the iTero is less accurate than scanning with the D250. Intraoral scanning with the iTero is less accurate than model scanning with the iTero, suggesting that the intraoral conditions (saliva, limited spacing) contribute to the inaccuracy of a scan. For treatment planning and manufacturing of tooth-supported appliances, virtual models created with the iTero can be used. An extended scanning protocol could improve the scanning results in some regions. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Some common indices of group diversity: upper boundaries.
Solanas, Antonio; Selvam, Rejina M; Navarro, José; Leiva, David
2012-12-01
Workgroup diversity can be conceptualized as variety, separation, or disparity. Thus, the proper operationalization of diversity depends on how a diversity dimension has been defined. Analytically, the minimal diversity must be obtained when there are no differences on an attribute among the members of a group, however maximal diversity has a different shape for each conceptualization of diversity. Previous work on diversity indexes indicated maximum values for variety (e.g., Blau's index and Teachman's index), separation (e.g., standard deviation and mean Euclidean distance), and disparity (e.g., coefficient of variation and the Gini coefficient of concentration), although these maximum values are not valid for all group characteristics (i.e., group size and group size parity) and attribute scales (i.e., number of categories). We demonstrate analytically appropriate upper boundaries for conditional diversity determined by some specific group characteristics, avoiding the bias related to absolute diversity. This will allow applied researchers to make better interpretations regarding the relationship between group diversity and group outcomes.
Nogami, Shinnosuke; Takahashi, Tetsu; Yamauchi, Kensuke; Miyamoto, Ikuya; Kaneuji, Takeshi; Yamamoto, Noriaki; Yoshiga, Daigo; Yamashita, Yoshihiro
2012-11-01
Endoscope-assisted transoral open reduction and internal fixation (EAORIF) for mandibular condyle fractures has recently become popular because it is minimally invasive, provides excellent visibility without a large incision, and reduces surgical scarring and the risk of facial nerve injury. This report describes a retrospective clinical study that compared certain clinical parameters, including postoperative function, between the retromandibular (RM) approach and EAORIF. Fifteen patients were treated by the RM approach, whereas 15 underwent EAORIF between July 2006 and September 2011 at Kyushu Dental College, Japan. Clinical indices comprised fracture line, fracture type, number of plates used, surgical duration, bleeding amount, and functional items, including maximum interincisal opening, mandibular deviation on the opening pathway, malocclusion, facial paresthesia, and temporomandibular joint pain and clicking. The areas subjected to either approach included lower neck and subcondyle. The RM approach was used for mandibular condyle fractures with dislocation of a small bone segment. Both groups used 2 plates in all cases. Surgical duration, maximum interincisal opening, mandibular deviation, occlusion, and temporomandibular joint function at 6 months after surgery were comparable between groups. The average bleeding amount in the EAORIF group was greater than in the RM group. One patient from the RM group developed facial paresthesia that persisted for 6 months after surgery. It was concluded that surgical treatment was suitable for fractures of the lower neck and subcondylar. Both procedures showed good results in the functional items of this study.
Silva, Andressa; Mello, Marco T.; Serrão, Paula R.; Luz, Roberta P.; Bittencourt, Lia R.; Mattiello, Stela M.
2015-01-01
OBJECTIVE: The aim of this study was to investigate whether obstructive sleep apnea (OSA) alters the fluctuation of submaximal isometric torque of the knee extensors in patients with early-grade osteoarthritis (OA). METHOD: The study included 60 male volunteers, aged 40 to 70 years, divided into four groups: Group 1 (G1) - Control (n=15): without OA and without OSA; Group 2 (G2) (n=15): with OA and without OSA; Group 3 (G3) (n=15): without OA and with OSA; and Group 4 (G4) (n=15) with OA and with OSA. Five patients underwent maximal isometric contractions of 10 seconds duration each, with the knee at 60° of flexion to determine peak torque at 60°. To evaluate the fluctuation of torque, 5 submaximal isometric contractions (50% of maximum peak torque) of 10 seconds each, which were calculated from the standard deviation of torque and coefficient of variation, were performed. RESULTS: Significant differences were observed between groups for maximum peak torque, while G4 showed a lower value compared with G1 (p=0.005). Additionally, for the average torque exerted, G4 showed a lower value compared to the G1 (p=0.036). However, no differences were found between the groups for the standard deviation (p=0.844) and the coefficient of variation (p=0.143). CONCLUSION: The authors concluded that OSA did not change the parameters of the fluctuation of isometric submaximal torque of knee extensors in patients with early-grade OA. PMID:26443974
Burghelea, Manuela; Verellen, Dirk; Poels, Kenneth; Gevaert, Thierry; Depuydt, Tom; Tournel, Koen; Hung, Cecilia; Simon, Viorica; Hiraoka, Masahiro; de Ridder, Mark
2015-07-15
The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry-ring (G/R) rotations during dynamic wave arc (DWA) delivery available on the Vero system. A verification method for DWA was developed to calculate O-ring-gantry (G/R) positional information from ball-bearing positions retrieved from fluoroscopic images of a cubic phantom acquired during DWA delivery. Different noncoplanar trajectories were generated in order to investigate the influence of path complexity on delivery accuracy. The G/R positions detected from the fluoroscopy images (DetPositions) were benchmarked against the G/R angulations retrieved from the control points (CP) of the DWA RT plan and the DWA log files recorded by the treatment console during DWA delivery (LogActed). The G/R rotational accuracy was quantified as the mean absolute deviation ± standard deviation. The maximum G/R absolute deviation was calculated as the maximum 3-dimensional distance between the CP and the closest DetPositions. In the CP versus DetPositions comparison, an overall mean G/R deviation of 0.13°/0.16° ± 0.16°/0.16° was obtained, with a maximum G/R deviation of 0.6°/0.2°. For the LogActed versus DetPositions evaluation, the overall mean deviation was 0.08°/0.15° ± 0.10°/0.10° with a maximum G/R of 0.3°/0.4°. The largest decoupled deviations registered for gantry and ring were 0.6° and 0.4° respectively. No directional dependence was observed between clockwise and counterclockwise rotations. Doubling the dose resulted in a double number of detected points around each CP, and an angular deviation reduction in all cases. An independent geometric quality assurance approach was developed for DWA delivery verification and was successfully applied on diverse trajectories. Results showed that the Vero system is capable of following complex G/R trajectories with maximum deviations during DWA below 0.6°. Copyright © 2015 Elsevier Inc. All rights reserved.
Information Entropy Production of Maximum Entropy Markov Chains from Spike Trains
NASA Astrophysics Data System (ADS)
Cofré, Rodrigo; Maldonado, Cesar
2018-01-01
We consider the maximum entropy Markov chain inference approach to characterize the collective statistics of neuronal spike trains, focusing on the statistical properties of the inferred model. We review large deviations techniques useful in this context to describe properties of accuracy and convergence in terms of sampling size. We use these results to study the statistical fluctuation of correlations, distinguishability and irreversibility of maximum entropy Markov chains. We illustrate these applications using simple examples where the large deviation rate function is explicitly obtained for maximum entropy models of relevance in this field.
Adaptive Gain-based Stable Power Smoothing of a DFIG
Muljadi, Eduard; Lee, Hyewon; Hwang, Min; ...
2017-11-01
In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combinationmore » with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. Here, the simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.« less
Adaptive Gain-based Stable Power Smoothing of a DFIG
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muljadi, Eduard; Lee, Hyewon; Hwang, Min
In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combinationmore » with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. Here, the simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.« less
40 CFR 86.1233-96 - Diurnal emission test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the underbody temperature sensor shall follow the profile with a maximum deviation of 3 °F at any time... temperature sensors shall follow the profile with a maximum deviation of 5 °F at any time. (2) Ambient... deionized water shall be placed in the methanol sampling system (methanol-fueled vehicles only). (3) Turn...
40 CFR 86.133-96 - Diurnal emission test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the underbody temperature sensor shall follow the profile with a maximum deviation of 3 °F at any time... temperature sensors shall follow the profile with a maximum deviation of 5 °F at any time. (2) Ambient... deionized water shall be placed in the methanol sampling system (methanol-fueled vehicles only). (3) Turn...
ERIC Educational Resources Information Center
Guo, Jiin-Huarng; Luh, Wei-Ming
2008-01-01
This study proposes an approach for determining appropriate sample size for Welch's F test when unequal variances are expected. Given a certain maximum deviation in population means and using the quantile of F and t distributions, there is no need to specify a noncentrality parameter and it is easy to estimate the approximate sample size needed…
Lee, Songil; Kyung, Gyouhyung; Lee, Jungyong; Moon, Seung Ki; Park, Kyoung Jong
2016-11-01
Recently, some smartphones have introduced index finger interaction functions on the rear surface. The current study investigated the effects of task type, phone width, and hand length on grasp, index finger reach zone, discomfort, and muscle activation during such interaction. We considered five interaction tasks (neutral, comfortable, maximum, vertical, and horizontal strokes), two device widths (60 and 90 mm) and three hand lengths. Horizontal (vertical) strokes deviated from the horizontal axis in the range from -10.8° to -13.5° (81.6-88.4°). Maximum strokes appeared to be excessive as these caused 43.8% greater discomfort than did neutral strokes. The 90-mm width also appeared to be excessive as it resulted in 12.3% increased discomfort relative to the 60-mm width. The small-hand group reported 11.9-18.2% higher discomfort ratings, and the percent maximum voluntary exertion of their flexor digitorum superficialis muscle, pertaining to index finger flexion, was also 6.4% higher. These findings should be considered to make smartphone rear interaction more comfortable. Practitioner Summary: Among neutral, comfortable, maximum, horizontal, and vertical index finger strokes on smartphone rear surfaces, maximum vs. neutral strokes caused 43.8% greater discomfort. Horizontal (vertical) strokes deviated from the horizontal (vertical) axis. Discomfort increased by 12.3% with 90-mm- vs. 60-mm-wide devices. Rear interaction regions of five commercialised smartphones should be lowered 20 to 30 mm for more comfortable rear interaction.
The effect of time in use on the display performance of the iPad.
Caffery, Liam J; Manthey, Kenneth L; Sim, Lawrence H
2016-07-01
The aim of this study was to evaluate changes to the luminance, luminance uniformity and conformance to the digital imaging and communication in medicine greyscale standard display function (GSDF) as a function of time in use for the iPad. Luminance measurements of the American Association of Physicists in Medicine (AAPM) Group 18 task group (TG18) luminance uniformity and luminance test patterns (TG18-UNL and TG18-LN8) were performed using a calibrated near-range luminance meter. Nine sets of measurements were taken, where the time in use of the iPad ranged from 0 to 2500 h. The maximum luminance (Lmax) of the display decreased (367-338 cdm(-2)) as a function of time. The minimum luminance remained constant. The maximum non-uniformity coefficient was 11%. Luminance uniformity decreased slightly as a function of time in use. The conformance of the iPad deviated from the GSDF curve at commencement of use. Deviation did not increase as a function of time in use. This study has demonstrated that the iPad display exhibits luminance degradation typical of liquid crystal displays. The Lmax of the iPad fell below the American College of Radiology-AAPM-Society of Imaging Informatics in Medicine recommendations for primary displays (>350 cdm(-2)) at approximately 1000 h in use. The Lmax recommendation for secondary displays (>250 cdm(-2)) was exceeded during the entire study. The maximum non-uniformity coefficient did not exceed the recommendations for either primary or secondary displays. The deviation from the GSDF exceeded the recommendations of the TG18 for use as either a primary or secondary display. The brightness, uniformity and contrast response are reasonably stable over the useful lifetime of the device; however, the device fails to meet the contrast response standard for either a primary or secondary display.
40 CFR 86.133-96 - Diurnal emission test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... according to the profile specified in § 86.133 and appendix II of this part. (1) Temperatures measured with the underbody temperature sensor shall follow the profile with a maximum deviation of 3 °F at any time... temperature sensors shall follow the profile with a maximum deviation of 5 °F at any time. (2) Ambient...
40 CFR 86.1233-96 - Diurnal emission test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... according to the profile specified in § 86.1233 and appendix II of this part. (1) Temperatures measured with the underbody temperature sensor shall follow the profile with a maximum deviation of 3 °F at any time... temperature sensors shall follow the profile with a maximum deviation of 5 °F at any time. (2) Ambient...
40 CFR 86.133-96 - Diurnal emission test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... according to the profile specified in § 86.133 and appendix II of this part. (1) Temperatures measured with the underbody temperature sensor shall follow the profile with a maximum deviation of 3 °F at any time... temperature sensors shall follow the profile with a maximum deviation of 5 °F at any time. (2) Ambient...
40 CFR 86.1233-96 - Diurnal emission test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... according to the profile specified in § 86.1233 and appendix II of this part. (1) Temperatures measured with the underbody temperature sensor shall follow the profile with a maximum deviation of 3 °F at any time... temperature sensors shall follow the profile with a maximum deviation of 5 °F at any time. (2) Ambient...
40 CFR 86.133-96 - Diurnal emission test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... according to the profile specified in § 86.133 and appendix II of this part. (1) Temperatures measured with the underbody temperature sensor shall follow the profile with a maximum deviation of 3 °F at any time... temperature sensors shall follow the profile with a maximum deviation of 5 °F at any time. (2) Ambient...
40 CFR 86.1233-96 - Diurnal emission test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... according to the profile specified in § 86.1233 and appendix II of this part. (1) Temperatures measured with the underbody temperature sensor shall follow the profile with a maximum deviation of 3 °F at any time... temperature sensors shall follow the profile with a maximum deviation of 5 °F at any time. (2) Ambient...
40 CFR 86.133-96 - Diurnal emission test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... according to the profile specified in § 86.133 and appendix II of this part. (1) Temperatures measured with the underbody temperature sensor shall follow the profile with a maximum deviation of 3 °F at any time... temperature sensors shall follow the profile with a maximum deviation of 5 °F at any time. (2) Ambient...
Predictive model for disinfection by-product in Alexandria drinking water, northern west of Egypt.
Abdullah, Ali M; Hussona, Salah El-dien
2013-10-01
Chlorine has been utilized in the early stages of water treatment processes as disinfectant. Disinfection for drinking water reduces the risk of pathogenic infection but may pose a chemical threat to human health due to disinfection residues and their by-products (DBP) when the organic and inorganic precursors are present in water. In the last two decades, many modeling attempts have been made to predict the occurrence of DBP in drinking water. Models have been developed based on data generated in laboratory-scale and field-scale investigations. The objective of this paper is to develop a predictive model for DBP formation in the Alexandria governorate located at the northern west of Egypt based on field-scale investigations as well as laboratory-controlled experimentations. The present study showed that the correlation coefficient between trihalomethanes (THM) predicted and THM measured was R (2)=0.88 and the minimum deviation percentage between THM predicted and THM measured was 0.8 %, the maximum deviation percentage was 89.3 %, and the average deviation was 17.8 %, while the correlation coefficient between dichloroacetic acid (DCAA) predicted and DCAA measured was R (2)=0.98 and the minimum deviation percentage between DCAA predicted and DCAA measured was 1.3 %, the maximum deviation percentage was 47.2 %, and the average deviation was 16.6 %. In addition, the correlation coefficient between trichloroacetic acid (TCAA) predicted and TCAA measured was R (2)=0.98 and the minimum deviation percentage between TCAA predicted and TCAA measured was 4.9 %, the maximum deviation percentage was 43.0 %, and the average deviation was 16.0 %.
Yin, Kedong; Wang, Pengyu; Li, Xuemei
2017-12-13
With respect to multi-attribute group decision-making (MAGDM) problems, where attribute values take the form of interval grey trapezoid fuzzy linguistic variables (IGTFLVs) and the weights (including expert and attribute weight) are unknown, improved grey relational MAGDM methods are proposed. First, the concept of IGTFLV, the operational rules, the distance between IGTFLVs, and the projection formula between the two IGTFLV vectors are defined. Second, the expert weights are determined by using the maximum proximity method based on the projection values between the IGTFLV vectors. The attribute weights are determined by the maximum deviation method and the priorities of alternatives are determined by improved grey relational analysis. Finally, an example is given to prove the effectiveness of the proposed method and the flexibility of IGTFLV.
Effect of visuospatial neglect on spatial navigation and heading after stroke.
Aravind, Gayatri; Lamontagne, Anouk
2017-06-09
Visuospatial neglect (VSN) impairs the control of locomotor heading in post-stroke individuals, which may affect their ability to safely avoid moving objects while walking. We aimed to compare VSN+ and VSN- stroke individuals in terms of changes in heading and head orientation in space while avoiding obstacles approaching from different directions and reorienting toward the final target. Stroke participants with VSN (VSN+) and without VSN (VSN-) walked in a virtual environment avoiding obstacles that approached contralesionally, head-on or ipsilesionally. Measures of obstacle avoidance (onset-of-heading change, maximum mediolateral deviation) and target alignment (heading and head-rotation errors with respect to target) were compared across groups and obstacle directions. In total, 26 participants with right-hemisphere stroke participated (13 VSN+ and 13 VSN-; 24 males; mean age 60.3 years, range 48 to 72 years). A larger proportion of VSN+ (75%) than VSN- (38%) participants collided with contralesional and head-on obstacles. For VSN- participants, deviating to the same side as the obstacle was a safe strategy to avoid diagonal obstacles and deviating to the opposite-side led to occasional collisions. VSN+ participants deviated ipsilesionally, displaying same-side and opposite-side strategies for ipsilesional and contralesional obstacles, respectively. Overall, VSN+ participants showed greater distances at onset-of-heading change, smaller maximum mediolateral deviation and larger errors in target alignment as compared with VSN- participants. The ipsilesional bias arising from VSN influences the modulation of heading in response to obstacles and, along with the adoption of the "riskier" strategies, contribute to the higher number colliders and poor goal-directed walking abilities in stroke survivors with VSN. Future research should focus on developing assessment and training tools for complex locomotor tasks such as obstacle avoidance in this population. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Holloway, Cpt Monica M; Jurina, Cpt Shannan L; Orszag, Cpt Joshua D; Bragdon, Lt George R; Green, Lt Rustin D; Garcia-Blanco, Jose C; Benham, Brian E; Adams, Ltc Timothy S; Johnson, Don
2016-01-01
To compare the effects of amiodarone administration by humerus intraosseous (HIO) and intravenous (IV) routes on return of spontaneous circulation (ROSC), time to maximum concentration (Tmax), maximum plasma drug concentration (Cmax), time to ROSC, and mean concentrations over time in a hypovolemic cardiac arrest model. Prospective, between subjects, randomized experimental design. TriService Research Facility. Yorkshire-cross swine (n = 28). Swine were anesthetized and placed into cardiac arrest. After 2 minutes, cardiopulmonary resuscitation was initiated. After an additional 2 minutes, amiodarone 300 mg was administered via the HIO or the IV route. Blood samples were collected over 5 minutes. The samples were analyzed using high-performance liquid chromatography tandem mass spectrometry. ROSC, Tmax, Cmax, time to ROSC, and mean concentrations over time. There was no difference in ROSC between the HIO and IV groups; each had five achieve ROSC and two that did not (p = 1). There was no difference in Tmax (p = 0.501) or in Cmax between HIO and IV groups (p = 0.232). Means ± standard deviations in seconds were 94.3 ± 78.3 compared to 115.7 ± 87.3 in the IV versus HIO groups, respectively. The mean ± standard deviation in nanograms per milliliter for the HIO was 49,041 ± 21,107 and 74,258 ± 33,176 for the IV group. There were no significant differences between the HIO and IV groups relative to time to ROSC (p = 0.220). A repeated analysis of variance indicated that there were no significant differences between the groups relative to concentrations over time (p > 0.05). The humerus intraosseous provides rapid and reliable access to administer life-saving medications during cardiac arrest.
Cybułka, Bartosz
2017-04-30
With current technological advancement and availability of synthetic materials used in inguinal hernia repair, a recurrence after first intervention is not a common and important adverse event. On the other hand, however, some patients complain about chronic pain of the operated site after surgeries using a polypropylene mesh. Many patients are constrained to a prolonged use of analgesics and increased frequency of control visits, which may eventually result in loss of trust in the operator. Every surgical intervention is associated with the risk of immediate or delayed complications. Genitofemoral neuralgia is associated with dysfunction of peripheral nerves passing through the inguinal canal or the surrounding tissue and it is a chronic, troublesome and undesired complication of an inguinal hernia repair. The possibility of minimizing chronic inguinal pain by proper management during herniorraphy should be considered in all cases of an inguinal canal reconstruction. The aim of the study was to investigate whether an intraoperative injection of 0.5% bupivacaine into the operated site (preemptive analgesia) has an influence on the postoperative pain assessed on the day of operation as well as the 1st and 2nd postoperative day after Lichtenstein hernioplasty of an inguinal, scrotal or recurrent hernia. In the studied population, we attempted to identify risk factors affecting pain level after surgical repair of an inguinal, scrotal or recurrent hernia. During the period between December 2015 and May 2016, 133 patients with preoperative diagnosis of an inguinal (81.95%, n=109), scrotal (13.53%, n=18) or recurrent hernia (4.51%, n=6) underwent an elective intervention and were randomly allocated to the group, which intraoperatively received 20 mL of 0.5% bupivacaine locally in selected anatomical points of the inguinal canal. In the group with preoperative diagnosis of an inguinal hernia, this intervention was applied in 56.88% of cases (n=62). In the case of scrotal or recurrent hernia, a similar intervention was applied in 41.67% (n=10) of patients. During the hospital stay, pain was assessed four times a day using the NRS numeric scale. All patients received preoperative antibiotic prophylaxis, and, during observation, analgesics and low-molecular-weight heparin were used. In the studied group, risk factor were identified, which affect the pain level associated with surgical treatment of an inguinal hernia. Mean pain level score according to the NRS scale (0-10) for an inguinal hernia was 4.17 on day 0 (standard deviation 2.22; minimum 0; maximum 10). On day 1 - 2.86 (standard deviation 1.86; minimum 0; maximum 8). On day 2 - 0.84 (standard deviation 1.21; minimum 0; maximum 5). The values of those parameters for a scrotal and recurrent hernia were as follows: on day 0 - 3.67 (standard deviation 1.76; minimum 0; maximum 7). On day 1 - 3.79 (standard deviation 1.67; minimum 0; maximum 7). On day 2 - 2.25 (standard deviation 1.54; minimum 0; maximum 4). Intraoperative application of 20 mL 0.5% bupivacaine did not reduce the postoperative pain on the postoperative day 0, 1, 2. Among independent risk factors exacerbating pain, the following variables were identified: local complications of the operated site including edema, ecchymosis and hematoma of the inguinal region. More frequent dressing changes were directly correlated with an increased pain sensation. Postoperative urethral catheterization due to urinary retention was associated with an increased pain immediately after surgery. In the case of intraoperative diagnosis of concurrent direct and indirect hernia (so-called pantaloon hernia), less intense pain was observed on postoperative day 0. Other parameters such as age, sex, duration of operation, duration of hospitalization and wound drainage did not influence the pain sensation. Local injection of an analgesic into the operated site was not associated with the reduction of pain assessed on postoperative day 0, 1 and 2 after an isolated inguinal, scrotal or recurrent hernia repair. Pathologies of the operated site such as edema, ecchymosis or hematoma were associated with an increased pain sensations on observation. Also, postoperative urinary retention and urethral catheterization increased the pain sensation after an inguinal hernia repair. A lack of wound complications significantly decreased the pain sensation during the immediate postoperative period after hernia repair.
Preliminary analysis of hot spot factors in an advanced reactor for space electric power systems
NASA Technical Reports Server (NTRS)
Lustig, P. H.; Holms, A. G.; Davison, H. W.
1973-01-01
The maximum fuel pin temperature for nominal operation in an advanced power reactor is 1370 K. Because of possible nitrogen embrittlement of the clad, the fuel temperature was limited to 1622 K. Assuming simultaneous occurrence of the most adverse conditions a deterministic analysis gave a maximum fuel temperature of 1610 K. A statistical analysis, using a synthesized estimate of the standard deviation for the highest fuel pin temperature, showed probabilities of 0.015 of that pin exceeding the temperature limit by the distribution free Chebyshev inequality and virtually nil assuming a normal distribution. The latter assumption gives a 1463 K maximum temperature at 3 standard deviations, the usually assumed cutoff. Further, the distribution and standard deviation of the fuel-clad gap are the most significant contributions to the uncertainty in the fuel temperature.
Irlenbusch, Ulrich; Berth, Alexander; Blatter, Georges; Zenz, Peter
2012-03-01
Most anthropometric data on the proximal humerus has been obtained from deceased healthy individuals with no deformities. Endoprostheses are implanted for primary and secondary osteoarthritis, rheumatoid arthritis,humeral-head necrosis, fracture sequelae and other humeral-head deformities. This indicates that pathologicoanatomical variability may be greater than previously assumed. We therefore investigated a group of patients with typical shoulder replacement diagnoses, including posttraumatic and rheumatic deformities. One hundred and twenty-two patients with a double eccentrically adjustable shaft endoprosthesis served as a specific dimension gauge to determine in vivo the individual humeral-head rotation centres from the position of the adjustable prosthesis taper and the eccentric head. All prosthesis heads were positioned eccentrically.The entire adjustment range of the prosthesis of 12 mm medial/lateral and 6 mm dorsal/ventral was required. Mean values for effective offset were 5.84 mm mediolaterally[standard deviation (SD) 1.95, minimum +2, maximum +11]and 1.71 mm anteroposteriorly (SD 1.71, minimum −3,maximum 3 mm), averaging 5.16 mm (SD 1.76, minimum +2,maximum + 10). The posterior offset averaged 1.85 mm(SD 1.85, minimum −1, maximum + 6 mm). In summary, variability of the combined medial and dorsal offset of the humeral-head rotational centre determined in patients with typical underlying diagnoses in shoulder replacement was not greater than that recorded in the literature for healthy deceased patients.The range of deviation is substantial and shows the need for an adjustable prosthetic system.
Alagar, Ananda Giri Babu; Mani, Ganesh Kadirampatti; Karunakaran, Kaviarasu
2016-01-08
Small fields smaller than 4 × 4 cm2 are used in stereotactic and conformal treatments where heterogeneity is normally present. Since dose calculation accuracy in both small fields and heterogeneity often involves more discrepancy, algorithms used by treatment planning systems (TPS) should be evaluated for achieving better treatment results. This report aims at evaluating accuracy of four model-based algorithms, X-ray Voxel Monte Carlo (XVMC) from Monaco, Superposition (SP) from CMS-Xio, AcurosXB (AXB) and analytical anisotropic algorithm (AAA) from Eclipse are tested against the measurement. Measurements are done using Exradin W1 plastic scintillator in Solid Water phantom with heterogeneities like air, lung, bone, and aluminum, irradiated with 6 and 15 MV photons of square field size ranging from 1 to 4 cm2. Each heterogeneity is introduced individually at two different depths from depth-of-dose maximum (Dmax), one setup being nearer and another farther from the Dmax. The central axis percentage depth-dose (CADD) curve for each setup is measured separately and compared with the TPS algorithm calculated for the same setup. The percentage normalized root mean squared deviation (%NRMSD) is calculated, which represents the whole CADD curve's deviation against the measured. It is found that for air and lung heterogeneity, for both 6 and 15 MV, all algorithms show maximum deviation for field size 1 × 1 cm2 and gradually reduce when field size increases, except for AAA. For aluminum and bone, all algorithms' deviations are less for 15 MV irrespective of setup. In all heterogeneity setups, 1 × 1 cm2 field showed maximum deviation, except in 6MV bone setup. All algorithms in the study, irrespective of energy and field size, when any heterogeneity is nearer to Dmax, the dose deviation is higher compared to the same heterogeneity far from the Dmax. Also, all algorithms show maximum deviation in lower-density materials compared to high-density materials.
Maximum Entropy, Word-Frequency, Chinese Characters, and Multiple Meanings
Yan, Xiaoyong; Minnhagen, Petter
2015-01-01
The word-frequency distribution of a text written by an author is well accounted for by a maximum entropy distribution, the RGF (random group formation)-prediction. The RGF-distribution is completely determined by the a priori values of the total number of words in the text (M), the number of distinct words (N) and the number of repetitions of the most common word (kmax). It is here shown that this maximum entropy prediction also describes a text written in Chinese characters. In particular it is shown that although the same Chinese text written in words and Chinese characters have quite differently shaped distributions, they are nevertheless both well predicted by their respective three a priori characteristic values. It is pointed out that this is analogous to the change in the shape of the distribution when translating a given text to another language. Another consequence of the RGF-prediction is that taking a part of a long text will change the input parameters (M, N, kmax) and consequently also the shape of the frequency distribution. This is explicitly confirmed for texts written in Chinese characters. Since the RGF-prediction has no system-specific information beyond the three a priori values (M, N, kmax), any specific language characteristic has to be sought in systematic deviations from the RGF-prediction and the measured frequencies. One such systematic deviation is identified and, through a statistical information theoretical argument and an extended RGF-model, it is proposed that this deviation is caused by multiple meanings of Chinese characters. The effect is stronger for Chinese characters than for Chinese words. The relation between Zipf’s law, the Simon-model for texts and the present results are discussed. PMID:25955175
Visual error augmentation enhances learning in three dimensions.
Sharp, Ian; Huang, Felix; Patton, James
2011-09-02
Because recent preliminary evidence points to the use of Error augmentation (EA) for motor learning enhancements, we visually enhanced deviations from a straight line path while subjects practiced a sensorimotor reversal task, similar to laparoscopic surgery. Our study asked 10 healthy subjects in two groups to perform targeted reaching in a simulated virtual reality environment, where the transformation of the hand position matrix was a complete reversal--rotated 180 degrees about an arbitrary axis (hence 2 of the 3 coordinates are reversed). Our data showed that after 500 practice trials, error-augmented-trained subjects reached the desired targets more quickly and with lower error (differences of 0.4 seconds and 0.5 cm Maximum Perpendicular Trajectory deviation) when compared to the control group. Furthermore, the manner in which subjects practiced was influenced by the error augmentation, resulting in more continuous motions for this group and smaller errors. Even with the extreme sensory discordance of a reversal, these data further support that distorted reality can promote more complete adaptation/learning when compared to regular training. Lastly, upon removing the flip all subjects quickly returned to baseline rapidly within 6 trials.
Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis
Freitas, Anderson; Lula, Welder Fernandes; de Oliveira, Jonathan Sampaio; Maciel, Rafael Almeida; Souto, Diogo Ranier de Macedo; Godinho, Patrick Fernandes
2014-01-01
OBJECTIVE: To analyze the results of biomechanical assays of fixation of Pauwels type III femoral neck fracture in synthetic bone, using 7.5mm cannulated screws in inverted triangle formation, in relation to the control group. METHODS: Ten synthetic bones were used, from a domestic brand, divided into two groups: test and control. In the test group, a 70° tilt osteotomy of the femoral neck was fixated using three cannulated screws in inverted triangle formation. The resistance of this fixation and its rotational deviation were analyzed at 5mm displacement (phase 1) and 10mm displacement (phase 2). The control group was tested in its integrity until the fracture of the femoral neck occurred. The Mann-Whitney test was used for group analysis and comparison. RESULTS: The values in the test group in phase 1, in samples 1-5, showed a mean of 579N and SD =77N. Rotational deviations showed a mean of 3.33°, SD = 2.63°. In phase 2, the mean was 696N and SD =106N. The values of the maximum load in the control group had a mean of 1329N and SD=177N. CONCLUSION: The analysis of mechanical strength between the groups determined a statistically significant lower value in the test group. Level of Evidence III, Control Case. PMID:25246851
Delmonico, Matthew J; Kostek, Matthew C; Doldo, Neil A; Hand, Brian D; Walsh, Sean; Conway, Joan M; Carignan, Craig R; Roth, Stephen M; Hurley, Ben F
2007-02-01
The alpha-actinin-3 (ACTN3) R577X polymorphism has been associated with muscle power performance in cross-sectional studies. We examined baseline knee extensor concentric peak power (PP) and PP change with approximately 10 weeks of unilateral knee extensor strength training (ST) using air-powered resistance machines in 71 older men (65 [standard deviation = 8] years) and 86 older women (64 [standard deviation = 9] years). At baseline in women, the XX genotype group had an absolute (same resistance) PP that was higher than the RR (p =.005) and RX genotype groups (p =.02). The women XX group also had a relative (70% of one-repetition maximum [1-RM]) PP that was higher than that in the RR (p =.002) and RX groups (p =.008). No differences in baseline absolute or relative PP were observed between ACTN3 genotype groups in men. In men, absolute PP change with ST in the RR (n = 16) group approached a significantly higher value than in the XX group (n = 9; p =.07). In women, relative PP change with ST in the RR group (n = 16) was higher than in the XX group (n = 17; p =.02). The results indicate that the ACTN3 R577X polymorphism influences the response of quadriceps muscle power to ST in older adults.
NASA Astrophysics Data System (ADS)
Tomza, Paweł; Wrzeszcz, Władysław; Mazurek, Sylwester; Szostak, Roman; Czarnecki, Mirosław Antoni
2018-05-01
Here we report ATR-IR spectroscopic study on the separation at a molecular level (microheterogeneity) and the degree of deviation of H2O/CH3OH and H2O/CD3OH mixtures from the ideal mixture. Of particular interest is the effect of isotopic substitution in methyl group on molecular structure and interactions in both mixtures. To obtain comprehensive information from the multivariate data we applied the excess molar absorptivity spectra together with two-dimensional correlation analysis (2DCOS) and chemometric methods. In addition, the experimental results were compared and discussed with the structures of various model clusters obtained from theoretical (DFT) calculations. Our results evidence the presence of separation at a molecular level and deviation from the ideal mixture for both mixtures. The experimental and theoretical results show that the maximum of these deviations appears at equimolar mixture. Both mixtures consist of three kinds of species: homoclusters of water and methanol and mixed clusters (heteroclusters). The heteroclusters exist in the whole range of mole fractions with the maximum close to the equimolar mixture. At this mixture composition near 55-60% of molecules are involved in heteroclusters. In contrast, the homoclusters of water occur in a limited range of mole fractions (XME < 0.85-0.9). Upon mixing the molecules of methanol form weaker hydrogen bonding as compared with the pure alcohol. In contrast, the molecules of water in the mixture are involved in stronger hydrogen bonding than those in bulk water. All these results indicate that both mixtures have similar degree of deviation from the ideal mixture.
Tomza, Paweł; Wrzeszcz, Władysław; Mazurek, Sylwester; Szostak, Roman; Czarnecki, Mirosław Antoni
2018-05-15
Here we report ATR-IR spectroscopic study on the separation at a molecular level (microheterogeneity) and the degree of deviation of H 2 O/CH 3 OH and H 2 O/CD 3 OH mixtures from the ideal mixture. Of particular interest is the effect of isotopic substitution in methyl group on molecular structure and interactions in both mixtures. To obtain comprehensive information from the multivariate data we applied the excess molar absorptivity spectra together with two-dimensional correlation analysis (2DCOS) and chemometric methods. In addition, the experimental results were compared and discussed with the structures of various model clusters obtained from theoretical (DFT) calculations. Our results evidence the presence of separation at a molecular level and deviation from the ideal mixture for both mixtures. The experimental and theoretical results show that the maximum of these deviations appears at equimolar mixture. Both mixtures consist of three kinds of species: homoclusters of water and methanol and mixed clusters (heteroclusters). The heteroclusters exist in the whole range of mole fractions with the maximum close to the equimolar mixture. At this mixture composition near 55-60% of molecules are involved in heteroclusters. In contrast, the homoclusters of water occur in a limited range of mole fractions (X ME < 0.85-0.9). Upon mixing the molecules of methanol form weaker hydrogen bonding as compared with the pure alcohol. In contrast, the molecules of water in the mixture are involved in stronger hydrogen bonding than those in bulk water. All these results indicate that both mixtures have similar degree of deviation from the ideal mixture. Copyright © 2018 Elsevier B.V. All rights reserved.
Precision of computer-assisted core decompression drilling of the femoral head.
Beckmann, J; Goetz, J; Baethis, H; Kalteis, T; Grifka, J; Perlick, L
2006-08-01
Osteonecrosis of the femoral head is a local destructive disease with progression into devastating stages. Left untreated it mostly leads to severe secondary osteoarthrosis and early endoprosthetic joint replacement. Core decompression by exact drilling into the ischemic areas can be performed in early stages according to Ficat or ARCO. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision navigation system in an in vitro model. Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. Twenty sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany) and 10 sawbones by fluoroscopic control only. No gypsum sphere was missed. There was a statistically significant difference regarding the three-dimensional deviation (Euclidian norm) as well as maximum deviation in x-, y- or z-direction (maximum norm) to the desired mid-point of the lesion, with a mean of 0.51 and 0.4 mm in the navigated group and 1.1 and 0.88 mm in the control group, respectively. Furthermore, significant difference was found in the number of drilling corrections as well as the radiation time needed: no second drilling or correction of drilling direction was necessary in the navigated group compared to 1.4 in the control group. The radiation time needed was less than 1 s compared to 3.1 s, respectively. The fluoroscopy-based VectorVision navigation system shows a high feasibility of computer-guided drilling with a clear reduction of radiation exposure time and can therefore be integrated into clinical routine. The additional time needed is acceptable regarding the simultaneous reduction of radiation time.
In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.
Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J
2004-01-01
In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.
4-Nitrobenzyl 2-bromoacetate
Zhu, Kai; Liu, Hui; Wang, Yan-Hua; Han, Ping-Fang; Wei, Ping
2009-01-01
In the molecule of the title compound, C9H8BrNO4, the acetate group is close to planar [maximum deviation = 0.042 (3) Å] and is oriented at a dihedral angle of 73.24 (3)° with respect to the aromatic ring. In the crystal structure, intermolecular C—H⋯O interactions link the molecules into a three-dimensional network, forming R 2 2(10) ring motifs. PMID:21582813
Mani, Ganesh Kadirampatti; Karunakaran, Kaviarasu
2016-01-01
Small fields smaller than 4×4 cm2 are used in stereotactic and conformal treatments where heterogeneity is normally present. Since dose calculation accuracy in both small fields and heterogeneity often involves more discrepancy, algorithms used by treatment planning systems (TPS) should be evaluated for achieving better treatment results. This report aims at evaluating accuracy of four model‐based algorithms, X‐ray Voxel Monte Carlo (XVMC) from Monaco, Superposition (SP) from CMS‐Xio, AcurosXB (AXB) and analytical anisotropic algorithm (AAA) from Eclipse are tested against the measurement. Measurements are done using Exradin W1 plastic scintillator in Solid Water phantom with heterogeneities like air, lung, bone, and aluminum, irradiated with 6 and 15 MV photons of square field size ranging from 1 to 4 cm2. Each heterogeneity is introduced individually at two different depths from depth‐of‐dose maximum (Dmax), one setup being nearer and another farther from the Dmax. The central axis percentage depth‐dose (CADD) curve for each setup is measured separately and compared with the TPS algorithm calculated for the same setup. The percentage normalized root mean squared deviation (%NRMSD) is calculated, which represents the whole CADD curve's deviation against the measured. It is found that for air and lung heterogeneity, for both 6 and 15 MV, all algorithms show maximum deviation for field size 1×1 cm2 and gradually reduce when field size increases, except for AAA. For aluminum and bone, all algorithms' deviations are less for 15 MV irrespective of setup. In all heterogeneity setups, 1×1 cm2 field showed maximum deviation, except in 6 MV bone setup. All algorithms in the study, irrespective of energy and field size, when any heterogeneity is nearer to Dmax, the dose deviation is higher compared to the same heterogeneity far from the Dmax. Also, all algorithms show maximum deviation in lower‐density materials compared to high‐density materials. PACS numbers: 87.53.Bn, 87.53.kn, 87.56.bd, 87.55.Kd, 87.56.jf PMID:26894345
On-line determination of transient stability status using multilayer perceptron neural network
NASA Astrophysics Data System (ADS)
Frimpong, Emmanuel Asuming; Okyere, Philip Yaw; Asumadu, Johnson
2018-01-01
A scheme to predict transient stability status following a disturbance is presented. The scheme is activated upon the tripping of a line or bus and operates as follows: Two samples of frequency deviation values at all generator buses are obtained. At each generator bus, the maximum frequency deviation within the two samples is extracted. A vector is then constructed from the extracted maximum frequency deviations. The Euclidean norm of the constructed vector is calculated and then fed as input to a trained multilayer perceptron neural network which predicts the stability status of the system. The scheme was tested using data generated from the New England test system. The scheme successfully predicted the stability status of all two hundred and five disturbance test cases.
Aweto, H A; Owoeye, O B A; Akinbo, S R A; Onabajo, A A
2012-01-01
Objective:Arterial hypertension is a medical condition associated with increased risks of of death, cardiovascular mortality and cardiovascular morbidity including stroke, coronary heart disease, atrial fibrillation and renal insufficiency. Regular physical exercise is considered to be an important part of the non-pharmacologictreatment of hypertension. The purpose of this study was to investigate the effects of dance movement therapy (DMT) on selected cardiovascular parameters and estimated maximum oxygen consumption in hypertensive patients. Fifty (50) subjects with hypertension participated in the study. They were randomly assigned to 2 equal groups; A (DMT group) and B (Control group). Group A carried out dance movement therapy 2 times a week for 4 weeks while group B underwent some educational sessions 2 times a week for the same duration. All the subjects were on anti-hypertensive drugs. 38 subjects completed the study with the DMTgroup having a total of 23 subjects (10 males and 13 females) and the control group 15 subjects (6 males and 9 females). Descriptive statistics of mean, standard deviation and inferential statistics of paired and independentt-testwere used for data analysis. Following four weeks of dance movement therapy, paired t-test analysis showed that there was a statistically significant difference in the Resting systolic blood pressure (RSBP) (p < 0.001*), Resting diastolic blood pressure (RDBP) (p < 0.001*), Resting heart rate (RHR) (p = 0.024*), Maximum heart rate (MHR) (p=0.002*) and Estimated oxygen consumption (VO2max) (p = 0.023*) in subjects in group A (p < 0.05) while there was no significant difference observed in outcome variables of subjects in group B (p > 0.05). Independent t-test analysis between the differences in the pre and post intervention scores of groups A and B also showed statistically significant differences in all the outcome variables (p <0.05). DMT was effective in improving cardiovascular parameters and estimated maximum oxygen consumption in hypertensive patients.
NASA Astrophysics Data System (ADS)
Mohammadian, Shahabeddin K.; Zhang, Yuwen
2015-01-01
Three dimensional transient thermal analysis of an air-cooled module that contains prismatic Li-ion cells next to a special kind of aluminum pin fin heat sink whose heights of pin fins increase linearly through the width of the channel in air flow direction was studied for thermal management of Lithium-ion battery pack. The effects of pin fins arrangements, discharge rates, inlet air flow velocities, and inlet air temperatures on the battery were investigated. The results showed that despite of heat sinks with uniform pin fin heights that increase the standard deviation of the temperature field, using this kind of pin fin heat sink compare to the heat sink without pin fins not only decreases the bulk temperature inside the battery, but also decreases the standard deviation of the temperature field inside the battery as well. Increasing the inlet air temperature leads to decreasing the standard deviation of the temperature field while increases the maximum temperature of the battery. Furthermore, increasing the inlet air velocity first increases the standard deviation of the temperature field till reaches to the maximum point, and after that decreases. Also, increasing the inlet air velocity leads to decrease in the maximum temperature of the battery.
Han, Zhifeng; Liu, Jianye; Li, Rongbing; Zeng, Qinghua; Wang, Yi
2017-07-04
BeiDou system navigation messages are modulated with a secondary NH (Neumann-Hoffman) code of 1 kbps, where frequent bit transitions limit the coherent integration time to 1 millisecond. Therefore, a bit synchronization algorithm is necessary to obtain bit edges and NH code phases. In order to realize bit synchronization for BeiDou weak signals with large frequency deviation, a bit synchronization algorithm based on differential coherent and maximum likelihood is proposed. Firstly, a differential coherent approach is used to remove the effect of frequency deviation, and the differential delay time is set to be a multiple of bit cycle to remove the influence of NH code. Secondly, the maximum likelihood function detection is used to improve the detection probability of weak signals. Finally, Monte Carlo simulations are conducted to analyze the detection performance of the proposed algorithm compared with a traditional algorithm under the CN0s of 20~40 dB-Hz and different frequency deviations. The results show that the proposed algorithm outperforms the traditional method with a frequency deviation of 50 Hz. This algorithm can remove the effect of BeiDou NH code effectively and weaken the influence of frequency deviation. To confirm the feasibility of the proposed algorithm, real data tests are conducted. The proposed algorithm is suitable for BeiDou weak signal bit synchronization with large frequency deviation.
Eguchi, Kazuo; Imaizumi, Yuki; Kaihara, Toshiki; Hoshide, Satoshi; Kario, Kazuomi
We tested the hypothesis that calcium channel blockers (CCBs: amlodipine group, n = 38)) are superior to angiotensin receptor blockers (ARBs: valsartan group, n = 38) against ambulatory blood pressure variability (BPV) in untreated Japanese hypertensive patients. Both drugs significantly reduced ambulatory systolic and diastolic BP values. With regard to BPV, standard deviation (SD) in SBP did not change with the administration of either drug, but the ARB significantly increased SD in awake DBP (12 ± 4-14 ± 4 mmHg). The ARB also significantly increased the coefficients of variation (CVs)in awake and 24-h SBP/DBP (all P < 0.05), but amlodipine did not change the CV. CCB significantly reduced the maximum values of awake SBP (193 ± 24-182 ± 27 mmHg, P = 0.02), sleep SBP (156 ± 18-139 ± 14 mmHg, P < 0 .001), and awake and sleep DBP (P < 0.01 in both cases), but the ARB did not change the maximum BP values. In conclusion, a once-daily morning dose of CCB amlodipine was more effective at controlling ambulatory BPV than ARB valsartan, especially in reducing maximum BP levels.
High dose rate brachytherapy source measurement intercomparison.
Poder, Joel; Smith, Ryan L; Shelton, Nikki; Whitaker, May; Butler, Duncan; Haworth, Annette
2017-06-01
This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR 192 Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single 192 Ir source using their own equipment and local protocols. Results were compared to the 192 Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for 192 Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Markovic, M; Stathakis, S; Jurkovic, I
2015-06-15
Purpose: The purpose of this study was to quantify performance of the nine detectors used for dosimetry measurements in advanced radiation therapy treatments. Methods: The 6 MV beam was utilized for measurements of the field sizes with the lack of lateral charge particle equilibrium. For dose fidelity aspect, energy dependence was studied by measuring PDD and profiles at different depths. The volume effect and its influence on the measured dose profiles have been observed by measuring detector’s response function. Output factor measurements with respect to change in energy spectrum have been performed and collected data has been analyzed. The linearitymore » of the measurements with the dose delivered has been evaluated and relevant comparisons were done. Results: The measured values of the output factors with respect to change in energy spectrum indicated presence of the energy dependence. The detectors with active volume size ≤ 0.3 mm3 maximum deviation from the mean is 5.6% for the field size 0.5 x 0.5 cm2 while detectors with active volume size > 0.3 mm3 have maximum deviation from the mean 7.1%. Linearity with dose at highest dose rate examined for diode detectors showed maximum deviation of 4% while ion chambers showed maximum deviation of 2.2%. Dose profiles showed energy dependence at shallow depths (surface to dmax) influenced by low energy particles with 12 % maximum deviation from the mean for 5 mm2 field size. In relation to Monte Carlo calculation, the detector’s response function σ values were between (0.42±0.25) mm and (1.2±0.25) mm. Conclusion: All the detectors are appropriate for the dosimetry measurements in advanced radiation therapy treatments. The choice of the detectors has to be determined by the application and the scope of the measurements in respect to energy dependence and ability to accurately resolve dose profiles as well as to it’s intrinsic characteristics.« less
Structural properties of a bone-ceramic composite as a promising material in spinal surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirilova, I. A., E-mail: IKirilova@mail.ru; Sadovoy, M. A.; Podorozhnaya, V. T., E-mail: VPodorognaya@niito.ru
The paper describes the results of in vitro tests of composite bone-ceramic implants and procedures for modifying implant surfaces to enhance osteogenesis. Analysis of CBCI ESs demonstrated that they have a porous structure with the mean longitudinal pore size of 70 µm and the mean transverse pore size of 46 µm; surface pores are open, while inner pores are closed. Elemental analysis of the CBCI surface demonstrates that CBCIs are composed of aluminum and zirconium oxides and contain HA inclusions. Profilometry of the CBCI ES surface revealed the following deviations: the maximum deviation of the profile in the sample center is 15 µmmore » and 16 µm on the periphery, while the arithmetical mean and mean square deviations of the profile are 2.65 and 3.4 µm, respectively. In addition, CBCI biodegradation products were pre-examined; a 0.9% NaCl solution was used as a comparison group. Potentially toxic and tissue accumulated elements, such as cadmium, cobalt, mercury, and lead, are present only in trace amounts and have no statistically significant differences with the comparison group, which precludes their potential toxic effects on the macroorganism. Ceramic-based CBCI may be effective and useful in medicine for restoration of the anatomic integrity and functions of the bone tissue.« less
Two-point method uncertainty during control and measurement of cylindrical element diameters
NASA Astrophysics Data System (ADS)
Glukhov, V. I.; Shalay, V. V.; Radev, H.
2018-04-01
The topic of the article is devoted to the urgent problem of the reliability of technical products geometric specifications measurements. The purpose of the article is to improve the quality of parts linear sizes control by the two-point measurement method. The article task is to investigate methodical extended uncertainties in measuring cylindrical element linear sizes. The investigation method is a geometric modeling of the element surfaces shape and location deviations in a rectangular coordinate system. The studies were carried out for elements of various service use, taking into account their informativeness, corresponding to the kinematic pairs classes in theoretical mechanics and the number of constrained degrees of freedom in the datum element function. Cylindrical elements with informativity of 4, 2, 1 and θ (zero) were investigated. The uncertainties estimation of in two-point measurements was made by comparing the results of of linear dimensions measurements with the functional diameters maximum and minimum of the element material. Methodical uncertainty is formed when cylindrical elements with maximum informativeness have shape deviations of the cut and the curvature types. Methodical uncertainty is formed by measuring the element average size for all types of shape deviations. The two-point measurement method cannot take into account the location deviations of a dimensional element, so its use for elements with informativeness less than the maximum creates unacceptable methodical uncertainties in measurements of the maximum, minimum and medium linear dimensions. Similar methodical uncertainties also exist in the arbitration control of the linear dimensions of the cylindrical elements by limiting two-point gauges.
Lila-Krasniqi, Zana D.; Shala, Kujtim Sh.; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Dula, Linda J.; Guguvčevski, Ljuben
2015-01-01
Objective: To compare subjects from the group with fixed dentures, the group who present temporomandibular disorders (TMDs) and a control group considering centric relation (CR) and maximum intercuspation (MIC)/habitual occlusion (Hab. Occl.) and to analyze the related variables also compared and analyzed with electronic system T-scan III. Materials and Methods: A total of 54 subjects were divided into three groups; 17 subjects with fixed dentures, 14 with TMD and 23 controls-selection based on anamnesis-responded to a Fonseca questionnaire and clinical measurements analyzed with electronic system T-scan III. Occlusal force, presented by percentage (automatically by the T-scan electronic system) was analyzed in CR and in MIC. Results: Data were presented as mean ± standard deviation and differences in P < 0.05 were considered significant. After measurements of the differences between CR and MIC in the three groups were noticed varieties but the P > 0.05 it was not significant in all three groups. Conclusion: In our study, it was concluded that there are not statistically significant differences between CR and MIC in the group of individuals without any symptom or sign of TMD although there are noticed in the group with TMD and fixed dentures disharmonic relation between the arches with overload of the occlusal force on the one side. PMID:26929698
Vocal Parameters of Elderly Female Choir Singers
Aquino, Fernanda Salvatico de; Ferreira, Léslie Piccolotto
2015-01-01
Introduction Due to increased life expectancy among the population, studying the vocal parameters of the elderly is key to promoting vocal health in old age. Objective This study aims to analyze the profile of the extension of speech of elderly female choristers, according to age group. Method The study counted on the participation of 25 elderly female choristers from the Choir of Messianic Church of São Paulo, with ages varying between 63 and 82 years, and an average of 71 years (standard deviation of 5.22). The elders were divided into two groups: G1 aged 63 to 71 years and G2 aged 72 to 82. We asked that each participant count from 20 to 30 in weak, medium, strong, and very strong intensities. Their speech was registered by the software Vocalgrama that allows the evaluation of the profile of speech range. We then submitted the parameters of frequency and intensity to descriptive analysis, both in minimum and maximum levels, and range of spoken voice. Results The average of minimum and maximum frequencies were respectively 134.82–349.96 Hz for G1 and 137.28–348.59 Hz for G2; the average for minimum and maximum intensities were respectively 40.28–95.50 dB for G1 and 40.63–94.35 dB for G2; the vocal range used in speech was 215.14 Hz for G1 and 211.30 Hz for G2. Conclusion The minimum and maximum frequencies, maximum intensity, and vocal range presented differences in favor of the younger elder group. PMID:26722341
Kok, H P; de Greef, M; Bel, A; Crezee, J
2009-08-01
In regional hyperthermia, optimization is useful to obtain adequate applicator settings. A speed-up of the previously published method for high resolution temperature based optimization is proposed. Element grouping as described in literature uses selected voxel sets instead of single voxels to reduce computation time. Elements which achieve their maximum heating potential for approximately the same phase/amplitude setting are grouped. To form groups, eigenvalues and eigenvectors of precomputed temperature matrices are used. At high resolution temperature matrices are unknown and temperatures are estimated using low resolution (1 cm) computations and the high resolution (2 mm) temperature distribution computed for low resolution optimized settings using zooming. This technique can be applied to estimate an upper bound for high resolution eigenvalues. The heating potential of elements was estimated using these upper bounds. Correlations between elements were estimated with low resolution eigenvalues and eigenvectors, since high resolution eigenvectors remain unknown. Four different grouping criteria were applied. Constraints were set to the average group temperatures. Element grouping was applied for five patients and optimal settings for the AMC-8 system were determined. Without element grouping the average computation times for five and ten runs were 7.1 and 14.4 h, respectively. Strict grouping criteria were necessary to prevent an unacceptable exceeding of the normal tissue constraints (up to approximately 2 degrees C), caused by constraining average instead of maximum temperatures. When strict criteria were applied, speed-up factors of 1.8-2.1 and 2.6-3.5 were achieved for five and ten runs, respectively, depending on the grouping criteria. When many runs are performed, the speed-up factor will converge to 4.3-8.5, which is the average reduction factor of the constraints and depends on the grouping criteria. Tumor temperatures were comparable. Maximum exceeding of the constraint in a hot spot was 0.24-0.34 degree C; average maximum exceeding over all five patients was 0.09-0.21 degree C, which is acceptable. High resolution temperature based optimization using element grouping can achieve a speed-up factor of 4-8, without large deviations from the conventional method.
Static balance according to hip joint angle of unsupported leg during one-leg standing.
Cha, Ju-Hyung; Kim, Jang-Joon; Ye, Jae-Gwan; Lee, Seul-Ji; Hong, Jeong-Mi; Choi, Hyun-Kyu; Choi, Ho-Suk; Shin, Won-Seob
2017-05-01
[Purpose] This study aimed to determine static balance according to hip joint angle of the unsupported leg during one-leg standing. [Subjects and Methods] Subjects included 45 healthy adult males and females in their 20s. During one-leg standing on the non-dominant leg, the position of the unsupported leg was classified according to hip joint angles of point angle was class. Static balance was then measured using a force plate with eyes open and closed. The total length, sway velocity, maximum deviation, and velocity on the mediolateral and anteroposterior axes of center of pressure were measured. [Results] In balance assessment with eyes open, there were significant differences between groups according to hip joint angle, except for maximum deviation on the anteroposterior axis. In balance assessment with eyes closed, there were significant differences between total length measurements at 0° and 30°, 60° and between 30° and 90°. There were significant differences between sway velocity measurements at 0° and 30° and between 30° and 90°. [Conclusion] Thus, there were differences in static balance according to hip joint angle. It is necessary to clearly identify the hip joint angle during one-leg standing testing.
Assessment of the maximum voluntary arm muscle contraction in sign language for the deaf.
Regalo, S C H; Teixeira, V R; Vitti, M; Chaves, T C; Hallak, J E C; Bevilaqua-Grossi, D; Siriani de Oliveira, A
2006-01-01
The purpose of this study was to investigate the levels of upper member muscles' activation of deaf individuals, who use the Brazilian sign language - LIBRAS, comparing these findings to volunteers with no postural deviations and normal hearing Forty eight volunteers divided into two groups comprising healthy and deaf subjects (24 volunteers for each group). The signs of rest were obtained with the volunteer maintaining the upper member in an anatomical position, but with the forearm flexed and sustained by the lower member. Maximum voluntary isometric contractions (MVIC) of the biceps, triceps, deltoid, and trapezius muscles were performed in the position of muscular function testing. Statistical analysis was performed using the SPSS-10.0. Continuous data with normal distribution were analyzed by ANOVA with the significance level of p < 0.01. The normalized electromyographic muscle data obtained in muscular rest do not show statistically significant differences among the studies muscles, in both groups. In the comparison of normalized RMS values obtained in MVIC, the mean values for the trapezius muscle of deaf group were statistically lower than control group. This study's results indicate there are no differences between the levels of muscular activation for arm biceps, arm triceps, and the anterior portion of the deltoid muscle between the mean normalized RMS values of deaf and healthy individuals.
NASA Astrophysics Data System (ADS)
Marichev, V. N.; Samokhvalov, I. V.
2014-11-01
In the article the lidar observations of the winter stratosphere warming manifestations of (SW) 2011-13 over Tomsk are considered. In 2010/11 the winter warming took place in January with insignificant positive temperature deviations from the mean monthly values in its first decade and then two maxima on the 14th and 15th of January at the altitude of 30-40 km with a deviation to 45K. In 2011/12 the beginning of the SW was recorded from lidar measurements on December 26 and lasted for two decades of January. The maximum development of SW was at the end of December 2011 - the first decade of January. The biggest temperature deviations were at the 40-60K level in the height interval of 35-45 km. In 2012/13 the SW began on December 25. The phase of its maximum development fell on the 1-4th of January when the stratopause altitude dropped on 30 km and the maximum temperature deviation from the model at this level reached 70K. In contrast to the first two warming (minor), the last was referred to the major type wherein air mass circulation change happened in the upper stratosphere over Tomsk ((http://www.geo.fu-berlin.de/en/met/ag/strat/index.html).).
Altuntepe, Emrah; Emel'yanenko, Vladimir N; Forster-Rotgers, Maximilian; Sadowski, Gabriele; Verevkin, Sergey P; Held, Christoph
2017-10-01
Levulinic acid was esterified with methanol, ethanol, and 1-butanol with the final goal to predict the maximum yield of these equilibrium-limited reactions as function of medium composition. In a first step, standard reaction data (standard Gibbs energy of reaction Δ R g 0 ) were determined from experimental formation properties. Unexpectedly, these Δ R g 0 values strongly deviated from data obtained with classical group contribution methods that are typically used if experimental standard data is not available. In a second step, reaction equilibrium concentrations obtained from esterification catalyzed by Novozym 435 at 323.15 K were measured, and the corresponding activity coefficients of the reacting agents were predicted with perturbed-chain statistical associating fluid theory (PC-SAFT). The so-obtained thermodynamic activities were used to determine Δ R g 0 at 323.15 K. These results could be used to cross-validate Δ R g 0 from experimental formation data. In a third step, reaction-equilibrium experiments showed that equilibrium position of the reactions under consideration depends strongly on the concentration of water and on the ratio of levulinic acid: alcohol in the initial reaction mixtures. The maximum yield of the esters was calculated using Δ R g 0 data from this work and activity coefficients of the reacting agents predicted with PC-SAFT for varying feed composition of the reaction mixtures. The use of the new Δ R g 0 data combined with PC-SAFT allowed good agreement to the measured yields, while predictions based on Δ R g 0 values obtained with group contribution methods showed high deviations to experimental yields.
Freitas, Anderson; Torres, Gustavo Melo; Souza, André Cezar de Andrade de Mello e; Maciel, Rafael Almeida; Souto, Diogo Ranier de Macedo; Ferreira, George Neri de Barros
2014-01-01
Objective To statistically analyze the results obtained from biomechanical tests on fixation of femoral neck fractures of Pauwels III type, in synthetic bone, using the dynamic hip system with an anti-rotation screw, versus a control group. Methods Ten synthetic bones from a Brazilian manufacturer (model C1010) were used and divided into two groups: test and control. In the test group, fixation of an osteotomy was performed with 70° of inclination at the level of the femoral neck, using DHS with an anti-rotation screw. The resistance of this fixation was evaluated, along with its rotational deviation at 5 mm of displacement (phase 1) and at 10 mm of displacement (phase 2), which was considered to be failure of synthesis. In the control group, the models were tested in their entirety until femoral neck fracturing occurred. Results The test values in the test group (samples 1–5) in phase 1 were: 1512 N, 1439 N, 1205 N, 1251 N and 1273 N, respectively (mean = 1336 N; standard deviation [SD] = 132 N). The rotational deviations were: 4.90°, 3.27°, 2.62°, 0.66° and 0.66°, respectively (mean = 2.42°; SD = 1.81°). In phase 2, we obtained: 2064 N, 1895 N, 1682 N, 1713 N and 1354 N, respectively (mean = 1742 N; SD = 265 N). The failure loading values in the control group were: 1544 N, 1110 N, 1359 N, 1194 N and 1437 N, respectively (mean = 1329 N; SD = 177 N). The statistical analysis using the Mann–Whitney test showed that the test group presented maximum loading at a displacement of 10 mm, i.e. significantly greater than the failure loading of the control group (p = 0.047). Conclusion The mechanical resistance of the test group was significantly greater than that of the control group. PMID:26229866
Intra-fraction motion of larynx radiotherapy
NASA Astrophysics Data System (ADS)
Durmus, Ismail Faruk; Tas, Bora
2018-02-01
In early stage laryngeal radiotherapy, movement is an important factor. Thyroid cartilage can move from swallowing, breathing, sound and reflexes. The effects of this motion on the target volume (PTV) during treatment were examined. In our study, the target volume movement during the treatment for this purpose was examined. Thus, setup margins are re-evaluated and patient-based PTV margins are determined. Intrafraction CBCT was scanned in 246 fractions for 14 patients. During the treatment, the amount of deviation which could be lateral, vertical and longitudinal axis was determined. ≤ ± 0.1cm deviation; 237 fractions in the lateral direction, 202 fractions in the longitudinal direction, 185 fractions in the vertical direction. The maximum deviation values were found in the longitudinal direction. Intrafraction guide in laryngeal radiotherapy; we are sure of the correctness of the treatment, the target volume is to adjust the margin and dose more precisely, we control the maximum deviation of the target volume for each fraction. Although the image quality of intrafraction-CBCT scans was lower than the image quality of planning CT, they showed sufficient contrast for this work.
Trilateral interlaboratory with SSL (WLEDi) luminaire
NASA Astrophysics Data System (ADS)
Burini Junior, E. C.; Santos, E. R.; Assaf, L. O.
2018-03-01
The IEE/USP laboratory and two others, all belonging to RBLE (Brazilian Network of Test Laboratories) participated in a trilateral comparison performed from measurement independently of participants interaction. The results from electric and photometric measurements carried out on samples of Solid State Lighting - SSL, Inorganic White Light Emitting Diode (WLEDi) luminaires by three accredited laboratories were considered in order to point out mutual deviations and to verify the confidence in a bilateral comparison. The first analysis revealed a maximum deviation of 4.2 % between the luminous intensity attributed by one laboratory and the arithmetic mean value from three laboratories. The largest standard uncertainty value of 1.9 % was estimated for Total Harmonic Distortion of electric current THDi and the lowest value, 0.4 %, to the luminous flux. The extreme deviation for one parameter results was 7.2 % at maximum luminous intensity and the lowest was 1.7 % for luminous flux.
N-[4-Cyano-3-(trifluoromethyl)phenyl]-2-ethoxybenzamide
Naveen, S.; Basappa; Manjunath, H. R.; Sridhar, M. A.; Shashidhara Prasad, J.; Rangappa, K. S.
2010-01-01
In the title compound, C17H13F3N2O2, the two aromatic rings are essentially coplanar, forming a dihedral angle of 2.78 (12)°. The non-H atoms of the ethoxy group are coplanar with the attached ring [maximum deviation = 0.271 (3) Å]. An intramolecular N—H⋯O hydrogen bond occurs. In the crystal structure, molecules are linked by intermolecular C—H⋯N and C—H⋯F hydrogen bonds. PMID:21587782
2,3-Dimethyl-6-nitro-2H-indazole
Chen, Yan; Fang, Zheng; Wei, Ping
2009-01-01
In the molecule of the title compound, C9H9N3O2, the indazole ring system is almost planar [maximum deviation = 0.019 (3) Å for the C atom bearing the nitro group]. In the crystal structure, intermolecular C—H⋯O interactions link the molecules into centrosymmetric dimers, forming R 2 2(18) ring motifs. Aromatic π–π contacts between indazole rings [centroid–centroid distances = 3.632 (1) and 3.705 (1) Å] may further stabilize the structure. PMID:21583483
Comparison of five-axis milling and rapid prototyping for implant surgical templates.
Park, Ji-Man; Yi, Tae-Kyoung; Koak, Jai-Young; Kim, Seong-Kyoon; Park, Eun-Jin; Heo, Seong-Joo
2014-01-01
This study aims to compare and evaluate the accuracy of surgical templates fabricated using coordinate synchronization processing with five-axis milling and design-related processing with rapid prototyping (RP). Master phantoms with 10 embedded gutta-percha cylinders hidden under artificial gingiva were fabricated and imaged using cone beam computed tomography. Vectors of the hidden cylinders were extracted and transferred to those of the planned implants through reverse engineering using virtual planning software. An RP-produced template was fabricated by stereolithography in photopolymer at the RP center according to planned data. Metal sleeves were bonded after holes were bored (group RP). For the milled template, milling coordinates were synchronized using the conversion process for the coordinate synchronization platform located on the model's bottom. Metal bushings were set on holes milled on the five-axis milling machine, on which the model was fixed through the coordinate synchronization plate, and the framework was constructed on the model using orthodontic resin (group CS). A computed tomography image was taken with templates firmly fixed on models using anchor pins (RP) or anchor screws (CS). The accuracy was analyzed via reverse engineering. Differences between the two groups were compared by repeated measures two-factor analysis. From the reverse-engineered image of the template on the experimental model, RP-produced templates showed significantly larger deviations than did milled surgical guides. Maximum deviations of the group RP were 1.58 mm (horizontal), 1.68 mm (vertical), and 8.51 degrees (angular); those of the group CS were 0.68 mm (horizontal), 0.41 mm (vertical), and 3.23 degrees (angular). A comparison of milling and RP template production methods showed that a vector-milled surgical guide had significantly smaller deviations than did an RP-produced template. The accuracy of computer-guided milled surgical templates was within the safety margin of previous studies.
Maeder, Angela B; Vonderheid, Susan C; Park, Chang G; Bell, Aleeca F; McFarlin, Barbara L; Vincent, Catherine; Carter, C Sue
To evaluate whether oxytocin titration for postdates labor induction differs among women who are normal weight, overweight, and obese and whether length of labor and birth method differ by oxytocin titration and body mass index (BMI). Retrospective cohort study. U.S. university-affiliated hospital. Of 280 eligible women, 21 were normal weight, 134 were overweight, and 125 were obese at labor admission. Data on women who received oxytocin for postdates induction between January 1, 2013 and June 30, 2013 were extracted from medical records. Oxytocin administration and labor outcomes were compared across BMI groups, controlling for potential confounders. Data were analyzed using χ 2 , analysis of variance, analysis of covariance, and multiple linear and logistic regression models. Women who were obese received more oxytocin than women who were overweight in the unadjusted analysis of variance (7.50 units compared with 5.92 units, p = .031). Women who were overweight had more minutes between rate changes from initiation to maximum than women who were obese (98.19 minutes compared with 83.39 minutes, p = .038). Length of labor increased with BMI (p = .018), with a mean length of labor for the normal weight group of 13.96 hours (standard deviation = 8.10); for the overweight group, 16.00 hours (standard deviation = 7.54); and for the obese group, 18.30 hours (standard deviation = 8.65). Cesarean rate increased with BMI (p = .001), with 4.8% of normal weight, 33.6% of overweight, and 42.4% of obese women having cesarean births. Women who were obese and experienced postdates labor induction received more oxytocin than women who were non-obese and had longer length of labor and greater cesarean rates. Copyright © 2017 AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses. Published by Elsevier Inc. All rights reserved.
Improved Bond Strength of Cyanoacrylate Adhesives Through Nanostructured Chromium Adhesion Layers
NASA Astrophysics Data System (ADS)
Gobble, Kyle; Stark, Amelia; Stagon, Stephen P.
2016-09-01
The performance of many consumer products suffers due to weak and inconsistent bonds formed to low surface energy polymer materials, such as polyolefin-based high-density polyethylene (HDPE), with adhesives, such as cyanoacrylate. In this letter, we present an industrially relevant means of increasing bond shear strength and consistency through vacuum metallization of chromium thin films and nanorods, using HDPE as a prototype material and cyanoacrylate as a prototype adhesive. For the as received HDPE surfaces, unmodified bond shear strength is shown to be only 0.20 MPa with a standard deviation of 14 %. When Cr metallization layers are added onto the HDPE at thicknesses of 50 nm or less, nanorod-structured coatings outperform continuous films and have a maximum bond shear strength of 0.96 MPa with a standard deviation of 7 %. When the metallization layer is greater than 50 nm thick, continuous films demonstrate greater performance than nanorod coatings and have a maximum shear strength of 1.03 MPa with a standard deviation of 6 %. Further, when the combination of surface roughening with P400 grit sandpaper and metallization is used, 100-nm-thick nanorod coatings show a tenfold increase in shear strength over the baseline, reaching a maximum of 2.03 MPa with a standard deviation of only 3 %. The substantial increase in shear strength through metallization, and the combination of roughening with metallization, may have wide-reaching implications in consumer products which utilize low surface energy plastics.
Emmanuel, Samson; Shantaram, Kulkarni; Sushil, Kumar C; Manoj, Likhitkar
2013-04-01
Success of non-surgical root canal treatment is predicted by meticulous cleaning and shaping of the root canal system, three-dimensional obturation and a well-fitting "leakage-free" coronal restoration. The techniques of obturation that are available have their own relative position in the historical development of filling techniques. Over the years, pitfalls with one technique have often led to the development of newer methods of obturation, along with the recognition that no one method of obturation may satisfy all clinical cases. A total of 120 extracted human permanent anterior maxillary and mandibular single rooted teeth were selected for the present study and divided into 3 groups based on the method of obturation technique. Following the preparation the patency at the apical foramen was confirmed by passing a file #15. After obturation of all three groups, teeth were immersed in 1% of aqueous methylene blue dye for a period of two weeks and then samples were subjected to spectrophotometric analysis. The present study was conducted to evaluate in vitro the spectrophotometric analysis to quantitatively analyze relative amount of dye penetration using lateral condensation (Group I), Obtura II (Group II ), Thermafil obturating technique (Group III) with ZOE sealer used in all groups. Teeth obturated with lateral condensation (Group I) shows mean value of 0.0243 and standard deviation of 0.0056. The Group II thermoplasticized injectable moulded Guttapercha (Obtura II) showed 0.0239 mean and standard deviation value of 0.0045 and Group III Thermafil obturation technique shows 0.0189 as mean value and 0.0035 standard deviation values. Following conclusion was drawn from the present study. Group III i.e., Thermafil obturating technique shows minimum mean apical dye penetration compared to Group II (ObturaII) and Group I (lateral condensation).Lateral condensation shows maximum mean apical dye penetration in all three groups.There is no significant difference between the apical dye penetration of lateral condensation and Obtura II. Obturation, lateral condensation, Obtura II, Thermafil, Spectrophotometer, dye penetration. How to cite this article: Samson E, Kulkarni S, Sushil K C, Likhitkar M. An In-Vitro Evaluation and Comparison of Apical Sealing Ability of Three Different Obturation Technique - Lateral Condensation, Obtura II, and Thermafil. J Int Oral Health 2013; 5(2):35-43.
Bolann, B J; Asberg, A
2004-01-01
The deviation of test results from patients' homeostatic set points in steady-state conditions may complicate interpretation of the results and the comparison of results with clinical decision limits. In this study the total deviation from the homeostatic set point is defined as the maximum absolute deviation for 95% of measurements, and we present analytical quality requirements that prevent analytical error from increasing this deviation to more than about 12% above the value caused by biology alone. These quality requirements are: 1) The stable systematic error should be approximately 0, and 2) a systematic error that will be detected by the control program with 90% probability, should not be larger than half the value of the combined analytical and intra-individual standard deviation. As a result, when the most common control rules are used, the analytical standard deviation may be up to 0.15 times the intra-individual standard deviation. Analytical improvements beyond these requirements have little impact on the interpretability of measurement results.
Analysis of using the tongue deviation angle as a warning sign of a stroke
2012-01-01
Background The symptom of tongue deviation is observed in a stroke or transient ischemic attack. Nevertheless, there is much room for the interpretation of the tongue deviation test. The crucial factor is the lack of an effective quantification method of tongue deviation. If we can quantify the features of the tongue deviation and scientifically verify the relationship between the deviation angle and a stroke, the information provided by the tongue will be helpful in recognizing a warning of a stroke. Methods In this study, a quantification method of the tongue deviation angle was proposed for the first time to characterize stroke patients. We captured the tongue images of stroke patients (15 males and 10 females, ranging between 55 and 82 years of age); transient ischemic attack (TIA) patients (16 males and 9 females, ranging between 53 and 79 years of age); and normal subjects (14 males and 11 females, ranging between 52 and 80 years of age) to analyze whether the method is effective. In addition, we used the receiver operating characteristic curve (ROC) for the sensitivity analysis, and determined the threshold value of the tongue deviation angle for the warning sign of a stroke. Results The means and standard deviations of the tongue deviation angles of the stroke, TIA, and normal groups were: 6.9 ± 3.1, 4.9 ± 2.1 and 1.4 ± 0.8 degrees, respectively. Analyzed by the unpaired Student’s t-test, the p-value between the stroke group and the TIA group was 0.015 (>0.01), indicating no significant difference in the tongue deviation angle. The p-values between the stroke group and the normal group, as well as between the TIA group and the normal group were both less than 0.01. These results show the significant differences in the tongue deviation angle between the patient groups (stroke and TIA patients) and the normal group. These results also imply that the tongue deviation angle can effectively identify the patient group (stroke and TIA patients) and the normal group. With respect to the visual examination, 40% and 32% of stroke patients, 24% and 16% of TIA patients, and 4% and 0% of normal subjects were found to have tongue deviations when physicians “A” and “B” examined them. The variation showed the essentiality of the quantification method in a clinical setting. In the receiver operating characteristic curve (ROC), the Area Under Curve (AUC, = 0.96) indicates good discrimination. The tongue deviation angle more than the optimum threshold value (= 3.2°) predicts a risk of stroke. Conclusions In summary, we developed an effective quantification method to characterize the tongue deviation angle, and we confirmed the feasibility of recognizing the tongue deviation angle as an early warning sign of an impending stroke. PMID:22908956
Analysis of using the tongue deviation angle as a warning sign of a stroke.
Wei, Ching-Chuan; Huang, Shu-Wen; Hsu, Sheng-Lin; Chen, Hsing-Chung; Chen, Jong-Shin; Liang, Hsinying
2012-08-21
The symptom of tongue deviation is observed in a stroke or transient ischemic attack. Nevertheless, there is much room for the interpretation of the tongue deviation test. The crucial factor is the lack of an effective quantification method of tongue deviation. If we can quantify the features of the tongue deviation and scientifically verify the relationship between the deviation angle and a stroke, the information provided by the tongue will be helpful in recognizing a warning of a stroke. In this study, a quantification method of the tongue deviation angle was proposed for the first time to characterize stroke patients. We captured the tongue images of stroke patients (15 males and 10 females, ranging between 55 and 82 years of age); transient ischemic attack (TIA) patients (16 males and 9 females, ranging between 53 and 79 years of age); and normal subjects (14 males and 11 females, ranging between 52 and 80 years of age) to analyze whether the method is effective. In addition, we used the receiver operating characteristic curve (ROC) for the sensitivity analysis, and determined the threshold value of the tongue deviation angle for the warning sign of a stroke. The means and standard deviations of the tongue deviation angles of the stroke, TIA, and normal groups were: 6.9 ± 3.1, 4.9 ± 2.1 and 1.4 ± 0.8 degrees, respectively. Analyzed by the unpaired Student's t-test, the p-value between the stroke group and the TIA group was 0.015 (>0.01), indicating no significant difference in the tongue deviation angle. The p-values between the stroke group and the normal group, as well as between the TIA group and the normal group were both less than 0.01. These results show the significant differences in the tongue deviation angle between the patient groups (stroke and TIA patients) and the normal group. These results also imply that the tongue deviation angle can effectively identify the patient group (stroke and TIA patients) and the normal group. With respect to the visual examination, 40% and 32% of stroke patients, 24% and 16% of TIA patients, and 4% and 0% of normal subjects were found to have tongue deviations when physicians "A" and "B" examined them. The variation showed the essentiality of the quantification method in a clinical setting. In the receiver operating characteristic curve (ROC), the Area Under Curve (AUC, = 0.96) indicates good discrimination. The tongue deviation angle more than the optimum threshold value (= 3.2°) predicts a risk of stroke. In summary, we developed an effective quantification method to characterize the tongue deviation angle, and we confirmed the feasibility of recognizing the tongue deviation angle as an early warning sign of an impending stroke.
Quantification of functional abilities in Rett syndrome: a comparison between stages III and IV
Monteiro, Carlos BM; Savelsbergh, Geert JP; Smorenburg, Ana RP; Graciani, Zodja; Torriani-Pasin, Camila; de Abreu, Luiz Carlos; Valenti, Vitor E; Kok, Fernando
2014-01-01
We aimed to evaluate the functional abilities of persons with Rett syndrome (RTT) in stages III and IV. The group consisted of 60 females who had been diagnosed with RTT: 38 in stage III, mean age (years) of 9.14, with a standard deviation of 5.84 (minimum 2.2/maximum 26.4); and 22 in stage IV, mean age of 12.45, with a standard deviation of 6.17 (minimum 5.3/maximum 26.9). The evaluation was made using the Pediatric Evaluation of Disability Inventory, which has 197 items in the areas of self-care, mobility, and social function. The results showed that in the area of self-care, stage III and stage IV RTT persons had a level of 24.12 and 18.36 (P=0.002), respectively. In the area of mobility, stage III had 37.22 and stage IV had 14.64 (P<0.001), while in the area of social function, stage III had 17.72 and stage IV had 12.14 (P=0.016). In conclusion, although persons with stage III RTT have better functional abilities when compared with stage IV, the areas of mobility, self-care, and social function are quite affected, which shows a great functional dependency and need for help in basic activities of daily life. PMID:25061307
Gonçalves, Fernanda de Cássia Papaiz; Amaral, Marina; Borges, Alexandre Luiz Souto; Gonçalves, Luiz Fernando Martins; Paes-Junior, Tarcisio José de Arruda
2018-04-01
Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (α=.05). The mean maximum load ±standard deviation for the molar group was 393.4 ±95.0 N with reinforcement and 305.4 ±76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 ±283.7 N with reinforcement and 605.3 ±90.5 N without reinforcement (P=.001). Reinforcement with nylon mesh increased the mean maximum load of implant-supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Beam deviation method as a diagnostic tool for the plasma focus.
Schmidt, H; Rückle, B
1978-04-15
The application of an optical method for density measurements in cylindrical plasmas is described. The angular deviation of a probing light beam sent through a plasma is proportional to the maximum of the density in the plasma column. The deviation does not depend on the plasma dimensions; however, it is influenced to a certain degree by the density profile. The method is successfully applied to the investigation of a dense plasma focus with a time resolution of 2 nsec and a spatial resolution (in axial direction) of 2 mm.
The most important physiological constants among the Volga region long-livers
NASA Astrophysics Data System (ADS)
Malinova, L. I.; Shuvalov, S. S.; Denisova, T. P.
2012-03-01
In our research we brought out the age difference in the group of long-livers and the continuous character of the biochemical basal metabolism indexes changing. The results allowed us to carry out the polynominal high-powered approximation to study the dynamics of laboratory indexes. We revealed the progressive reduction of the cholesterol, triglycerides, glucose and creatinine levels starting from 90 years of age, and this reduction showed the non-linear character with interchange of local minimums and maximums. During the speed characteristics analysis we revealed the cooccurrence of the speed maximums of all the examined biochemical indexes, except the speed of changing the concentration of cholesterol, which maximum took the lead over the other indexes by four years. The phase-plane portrait analysis of the regulatory systems on the plane "time - speed" showed the unfulfilled attempt of system stabilization by all the searched parameters nearby the special spot - "stable focus". The standard deviation values analysis of the researched parameters showed their progressive reduction in the long-livers. That fact can be considered as the regulatory systems physiological "backlash" reduction among the centenarians.
The linear sizes tolerances and fits system modernization
NASA Astrophysics Data System (ADS)
Glukhov, V. I.; Grinevich, V. A.; Shalay, V. V.
2018-04-01
The study is carried out on the urgent topic for technical products quality providing in the tolerancing process of the component parts. The aim of the paper is to develop alternatives for improving the system linear sizes tolerances and dimensional fits in the international standard ISO 286-1. The tasks of the work are, firstly, to classify as linear sizes the elements additionally linear coordinating sizes that determine the detail elements location and, secondly, to justify the basic deviation of the tolerance interval for the element's linear size. The geometrical modeling method of real details elements, the analytical and experimental methods are used in the research. It is shown that the linear coordinates are the dimensional basis of the elements linear sizes. To standardize the accuracy of linear coordinating sizes in all accuracy classes, it is sufficient to select in the standardized tolerance system only one tolerance interval with symmetrical deviations: Js for internal dimensional elements (holes) and js for external elements (shafts). The main deviation of this coordinating tolerance is the average zero deviation, which coincides with the nominal value of the coordinating size. Other intervals of the tolerance system are remained for normalizing the accuracy of the elements linear sizes with a fundamental change in the basic deviation of all tolerance intervals is the maximum deviation corresponding to the limit of the element material: EI is the lower tolerance for the of the internal elements (holes) sizes and es is the upper tolerance deviation for the outer elements (shafts) sizes. It is the sizes of the material maximum that are involved in the of the dimensional elements mating of the shafts and holes and determine the fits type.
Friedman, S N; Bambrough, P J; Kotsarini, C; Khandanpour, N; Hoggard, N
2012-12-01
Despite the established role of MRI in the diagnosis of brain tumours, histopathological assessment remains the clinically used technique, especially for the glioma group. Relative cerebral blood volume (rCBV) is a dynamic susceptibility-weighted contrast-enhanced perfusion MRI parameter that has been shown to correlate to tumour grade, but assessment requires a specialist and is time consuming. We developed analysis software to determine glioma gradings from perfusion rCBV scans in a manner that is quick, easy and does not require a specialist operator. MRI perfusion data from 47 patients with different histopathological grades of glioma were analysed with custom-designed software. Semi-automated analysis was performed with a specialist and non-specialist operator separately determining the maximum rCBV value corresponding to the tumour. Automated histogram analysis was performed by calculating the mean, standard deviation, median, mode, skewness and kurtosis of rCBV values. All values were compared with the histopathologically assessed tumour grade. A strong correlation between specialist and non-specialist observer measurements was found. Significantly different values were obtained between tumour grades using both semi-automated and automated techniques, consistent with previous results. The raw (unnormalised) data single-pixel maximum rCBV semi-automated analysis value had the strongest correlation with glioma grade. Standard deviation of the raw data had the strongest correlation of the automated analysis. Semi-automated calculation of raw maximum rCBV value was the best indicator of tumour grade and does not require a specialist operator. Both semi-automated and automated MRI perfusion techniques provide viable non-invasive alternatives to biopsy for glioma tumour grading.
Netherton, Tucker; Li, Yuting; Nitsch, Paige; Shaitelman, Simona; Balter, Peter; Gao, Song; Klopp, Ann; Muruganandham, Manickam; Court, Laurence
2018-06-01
Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. To study lung interplay, eight VMAT plans (1-6 arcs) and four-nine-field sliding-window IMRT plans varying in complexity were created. For the breast plans, four-four-field sliding-window IMRT plans were created. Using the Halcyon 1.0 linear accelerator, each plan was delivered five times each under sinusoidal breathing motion to a phantom with 20 implanted MOSFET detectors; MOSFET dose (cGy), delivery time, and MU/cGy values were recorded. Maximum and mean dose deviations were calculated from MOSFET data. The number of MOSFETs with at least 19 of 20 detectors agreeing with their expected dose within 5% per fraction was calculated across 10 6 iterations to model dose deviation as function of fraction number for all plan variants. To put interplay plans into clinical context, additional IMRT and VMAT plans were created and delivered for the sites of head and neck, prostate, whole brain, breast, pelvis, and lung. Average modulation and interplay effect were compared to those from conventional linear accelerators, as reported from previous studies. The mean beam modulation for plans created for the Halcyon 1.0 linear accelerator was 2.9 MU/cGy (two- to four-field IMRT breast plans), 6.2 MU/cGy (at least five-field IMRT), and 3.6 MU/cGy (four-arc VMAT). To achieve treatment plan objectives, Halcyon 1.0 VMAT plans require more arcs and modulation than VMAT on conventional linear accelerators. Maximum and mean dose deviations increased with increasing plan complexity under tumor motion for breast and lung treatments. Concerning VMAT plans under motion, maximum, and mean dose deviations were higher for one arc than for two arcs regardless of plan complexity. For plan variants with maximum dose deviations greater than 3.7%, dose deviation as a function of fraction number was protracted. For treatments on the Halcyon 1.0 linear accelerator, the convergence of dose deviation with fraction number happened more slowly than reported for conventional linear accelerators. However, if plan complexity is reduced for IMRT and if tumor motion is less than ~10-mm, interplay is greatly reduced. To minimize dose deviations across multiple fractions for dynamic targets, we recommend limiting treatment plan complexity and avoiding one-arc VMAT on the Halcyon 1.0 linear accelerator when interplay is a concern. © 2018 American Association of Physicists in Medicine.
Error Estimates of the Ares I Computed Turbulent Ascent Longitudinal Aerodynamic Analysis
NASA Technical Reports Server (NTRS)
Abdol-Hamid, Khaled S.; Ghaffari, Farhad
2012-01-01
Numerical predictions of the longitudinal aerodynamic characteristics for the Ares I class of vehicles, along with the associated error estimate derived from an iterative convergence grid refinement, are presented. Computational results are based on an unstructured grid, Reynolds-averaged Navier-Stokes analysis. The validity of the approach to compute the associated error estimates, derived from a base grid to an extrapolated infinite-size grid, was first demonstrated on a sub-scaled wind tunnel model at representative ascent flow conditions for which the experimental data existed. Such analysis at the transonic flow conditions revealed a maximum deviation of about 23% between the computed longitudinal aerodynamic coefficients with the base grid and the measured data across the entire roll angles. This maximum deviation from the wind tunnel data was associated with the computed normal force coefficient at the transonic flow condition and was reduced to approximately 16% based on the infinite-size grid. However, all the computed aerodynamic coefficients with the base grid at the supersonic flow conditions showed a maximum deviation of only about 8% with that level being improved to approximately 5% for the infinite-size grid. The results and the error estimates based on the established procedure are also presented for the flight flow conditions.
Bias and Efficiency in Structural Equation Modeling: Maximum Likelihood versus Robust Methods
ERIC Educational Resources Information Center
Zhong, Xiaoling; Yuan, Ke-Hai
2011-01-01
In the structural equation modeling literature, the normal-distribution-based maximum likelihood (ML) method is most widely used, partly because the resulting estimator is claimed to be asymptotically unbiased and most efficient. However, this may not hold when data deviate from normal distribution. Outlying cases or nonnormally distributed data,…
2,3-Diamino-pyridinium sorbate-sorbic acid (1/1).
Hemamalini, Madhukar; Goh, Jia Hao; Fun, Hoong-Kun
2012-01-01
In the title mol-ecular salt-adduct, C(5)H(8)N(3) (+)·C(6)H(7)O(2) (-)·C(6)H(8)O(2), the 2,3-diamino-pyridinium cation is essentially planar, with a maximum deviation of 0.013 (2) Å, and is protanated at its pyridine N atom. The sorbate anion and sorbic acid mol-ecules exist in extended conformations. In the crystal, the protonated N atom and one of the two amino-group H atoms are hydrogen bonded to the sorbate anion through a pair of N-H⋯O hydrogen bonds, forming an R(1) (2)(6) ring motif. The carboxyl groups of the sorbic acid mol-ecules and the carboxyl-ate groups of the sorbate anions are connected via O-H⋯O hydrogen bonds. Furthermore, the ion pairs and neutral mol-ecules are connected via inter-molecular N-H⋯O hydrogen bonds, forming sheets lying parallel to (100).
Qualitative computer aided evaluation of dental impressions in vivo.
Luthardt, Ralph G; Koch, Rainer; Rudolph, Heike; Walter, Michael H
2006-01-01
Clinical investigations dealing with the precision of different impression techniques are rare. Objective of the present study was to develop and evaluate a procedure for the qualitative analysis of the three-dimensional impression precision based on an established in-vitro procedure. The zero hypothesis to be tested was that the precision of impressions does not differ depending on the impression technique used (single-step, monophase and two-step-techniques) and on clinical variables. Digital surface data of patient's teeth prepared for crowns were gathered from standardized manufactured master casts after impressions with three different techniques were taken in a randomized order. Data-sets were analyzed for each patient in comparison with the one-step impression chosen as the reference. The qualitative analysis was limited to data-points within the 99.5%-range. Based on the color-coded representation areas with maximum deviations were determined (preparation margin and the mantle and occlusal surface). To qualitatively analyze the precision of the impression techniques, the hypothesis was tested in linear models for repeated measures factors (p < 0.05). For the positive 99.5% deviations no variables with significant influence were determined in the statistical analysis. In contrast, the impression technique and the position of the preparation margin significantly influenced the negative 99.5% deviations. The influence of clinical parameter on the deviations between impression techniques can be determined reliably using the 99.5 percentile of the deviations. An analysis regarding the areas with maximum deviations showed high clinical relevance. The preparation margin was pointed out as the weak spot of impression taking.
Bubble Dynamics and Resulting Noise from Traveling Bubble Cavitation.
1982-04-13
proportional to the gas content. The subjectivity of visual cavitation determination is evidenced by the maximum standard deviation. As mentioned before...bubble radii at the maximum radius position on the model. The point on the model where the bubble will be at its maximum volume was determined by...48 3.7 Recording Bubble Dynamics . • . * . . . . 52 3.8 Measurement of Gas Nuclei in Water 0 • 52 3 TABLE OF CONTENTS (continued) Paqe
la Garza, Francisco Javier Guzmán-de; Ibarra-Hernández, Juan Manuel; Cordero-Pérez, Paula; Villegas-Quintero, Pablo; Villarreal-Ovalle, Claudia Ivette; Torres-González, Liliana; Oliva-Sosa, Norma Edith; Alarcón-Galván, Gabriela; Fernández-Garza, Nancy Esthela; Muñoz-Espinosa, Linda Elsa; Cámara-Lemarroy, Carlos Rodrigo; Carrillo-Arriaga, José Gerardo
2013-01-01
OBJECTIVE: It is essential to identify a serological marker of injury in order to study the pathophysiology of intestinal ischemia reperfusion. In this work, we studied the evolution of several serological markers after intestinal ischemia reperfusion injury in rats. The markers of non-specific cell damage were aspartate aminotransferase, alanine aminotransaminase, and lactic dehydrogenase, the markers of inflammation were tumor necrosis factor alpha, interleukin-6, and interleukin-1 beta, and the markers of intestinal mucosal damage were intestinal fatty acid binding protein and D-lactate. We used Chiús classification to grade the histopathological damage. METHODS: We studied 35 Wistar rats divided into groups according to reperfusion time. The superior mesenteric artery was clamped for 30 minutes, and blood and biopsies were collected at 1, 3, 6, 12, 24, and 48 hours after reperfusion. We plotted the mean ± standard deviation and compared the baseline and maximum values for each marker using Student's t-test. RESULTS: The maximum values of interleukin-1 beta and lactic dehydrogenase were present before the maximal histopathological damage. The maximum tumor necrosis factor alpha and D-lactate expressions coincided with histopathological damage. Alanine aminotransaminase and aspartate aminotransferase had a maximum expression level that increased following the histopathological damage. The maximum expressions of interluken-6 and intestinal fatty acid binding protein were not significantly different from the Sham treated group. CONCLUSION: For the evaluation of injury secondary to acute intestinal ischemia reperfusion with a 30 minute ischemia period, we recommend performing histopathological grading, quantification of D-lactate, which is synthesized by intestinal bacteria and is considered an indicator of mucosal injury, and quantification of tumor necrosis factor alpha as indicators of acute inflammation three hours after reperfusion. PMID:23917671
Perception of midline deviations in smile esthetics by laypersons.
Ferreira, Jamille Barros; Silva, Licínio Esmeraldo da; Caetano, Márcia Tereza de Oliveira; Motta, Andrea Fonseca Jardim da; Cury-Saramago, Adriana de Alcantara; Mucha, José Nelson
2016-01-01
To evaluate the esthetic perception of upper dental midline deviation by laypersons and if adjacent structures influence their judgment. An album with 12 randomly distributed frontal view photographs of the smile of a woman with the midline digitally deviated was evaluated by 95 laypersons. The frontal view smiling photograph was modified to create from 1 mm to 5 mm deviations in the upper midline to the left side. The photographs were cropped in two different manners and divided into two groups of six photographs each: group LCN included the lips, chin, and two-thirds of the nose, and group L included the lips only. The laypersons performed the rate of each smile using a visual analog scale (VAS). Wilcoxon test, Student's t-test and Mann-Whitney test were applied, adopting a 5% level of significance. Laypersons were able to perceive midline deviations starting at 1 mm. Statistically significant results (p< 0.05) were found for all multiple comparisons of the values in photographs of group LCN and for almost all comparisons in photographs of group L. Comparisons between the photographs of groups LCN and L showed statistically significant values (p< 0.05) when the deviation was 1 mm. Laypersons were able to perceive the upper dental midline deviations of 1 mm, and above when the adjacent structures of the smiles were included. Deviations of 2 mm and above when the lips only were included. The visualization of structures adjacent to the smile demonstrated influence on the perception of midline deviation.
Vasak, Christoph; Watzak, Georg; Gahleitner, André; Strbac, Georg; Schemper, Michael; Zechner, Werner
2011-10-01
This prospective study was intended to evaluate the overall deviation in a clinical treatment setting to provide for quantification of the potential impairment of treatment safety and reliability with computer-assisted, template-guided transgingival implantation. The patient population enrolled (male/female=10/8) presented with partially dentate and edentulous maxillae and mandibles. Overall, 86 implants were placed by two experienced dental surgeons strictly following the NobelGuide™ protocol for template-guided implantation. All patients had a postoperative computed tomography (CT) with identical settings to the preoperative examination. Using the triple scan technique, pre- and postoperative CT data were merged in the Procera planning software, a newly developed procedure - initially presented in 2007 allowing measurement of the deviations at implant shoulder and apex. The deviations measured were an average of 0.43 mm (bucco-lingual), 0.46 mm (mesio-distal) and 0.53 mm (depth) at the level of the implant shoulder and slightly higher at the implant apex with an average of 0.7 mm (bucco-lingual), 0.63 mm (mesio-distal) and 0.52 mm (depth). The maximum deviation of 2.02 mm was encountered in the corono-apical direction. Significantly lower deviations were seen for implants in the anterior region vs. the posterior tooth region (P<0.01, 0.31 vs. 0.5 mm), and deviations were also significantly lower in the mandible than in the maxilla (P=0.04, 0.36 vs. 0.45 mm) in the mesio-distal direction. Moreover, a significant correlation between deviation and mucosal thickness was seen and a learning effect was found over the time period of performance of the surgical procedures. Template-guided implantation will ensure reliable transfer of preoperative computer-assisted planning into surgical practice. With regard to the required verification of treatment reliability of an implantation system with flapless access, all maximum deviations measured in this clinical study were within the safety margins recommended by the planning software. © 2011 John Wiley & Sons A/S.
Özler, Gül Soylu
2016-01-01
The author conducted a prospective study of patients who underwent septoplasty for nasal obstruction secondary to a septal deviation to determine if the location of the deviation had any association with the degree of postoperative pain. Patients with an anteroposterior deviation were not included in this study, nor were patients with vasomotor rhinitis, allergic rhinitis, nasal polyposis, turbinate pathologies, or a systemic disease; also excluded were patients who were taking any medication and those who had undergone any previous nasal surgery. The final study population included 140 patients, who were divided into two groups on the basis of the location of their deviation. A total of 64 patients (35 men and 29 women; mean age: 29.8 yr) had an anterior deviation, and 76 patients (35 men and 41 women; mean age: 30.3 yr) had a posterior deviation; there were no statistically significant differences between the two groups in terms of sex (p = 0.309) or age (p = 0.848). During the postoperative period, pain intensity in both groups was self-evaluated on a visual analog scale on days 1, 3, and 7 and again at 3 and 6 months. The mean postoperative pain scores on days 1, 3, and 7 were significantly higher in the posterior deviation group than in the anterior group; scores in the two groups were similar at 3 and 6 months.
Improving excellence in scoliosis rehabilitation: a controlled study of matched pairs.
Weiss, H-R; Klein, R
2006-01-01
Physiotherapy programmes so far mainly address the lateral deformity of scoliosis, a few aim at the correction of rotation and only very few address the sagittal profile. Meanwhile, there is evidence that correction forces applied in the sagittal plane are also able to correct the scoliotic deformity in the coronal and frontal planes. So it should be possible to improve excellence in scoliosis rehabilitation by the implementation of exercises to correct the sagittal deformity in scoliosis patients. An exercise programme (physio-logic exercises) aiming at a physiologic sagittal profile was developed to add to the programme applied at the centre or to replace certain exercises or exercising positions. To test the hypothesis that physio-logic exercises improve the outcome of Scoliosis Intensive Rehabilitation (SIR), the following study design was chosen: Prospective controlled trial of pairs of patients with idiopathic scoliosis matched by sex, age, Cobb angle and curve pattern. There were 18 patients in the treatment group (SIR + physio-logic exercises) and 18 patients in the control group (SIR only), all in matched pairs. Average Cobb angle in the treatment group was 34.5 degrees (SD 7.8) Cobb angle in the control group was 31.6 degrees (SD 5.8). Age in the treatment group was at average 15.3 years (SD 1.1) and in the control group 14.7 years (SD 1.3). Thirteen of the 18 patients in either group had a brace. Outcome parameter: average lateral deviation (mm), average surface rotation ( degrees ) and maximum Kyphosis angle ( degrees ) as evaluated with the help of surface topography (Formetric-system). Lateral deviation (mm) decreased significantly after the performance of the physio-logic programme and highly significantly in the physio-logic ADL posture; however, it was not significant after completion of the whole rehabilitation programme (2.3 vs 0.3 mm in the controls). Surface rotation improved at average 1.2 degrees in the treatment group and 0.8 degrees in the controls while Kyphosis angle did not improve in both groups. The physio-logic programme has to be regarded as a useful 'add on' to Scoliosis Rehabilitation with regards to the lateral deviation of the scoliotic trunk. A longitudinal controlled study is necessary to evaluate the long-term effect of the the physio-logic programme also with the help of X-rays.
Zhang, Lin; Huttin, Olivier; Marie, Pierre-Yves; Felblinger, Jacques; Beaumont, Marine; Chillou, Christian DE; Girerd, Nicolas; Mandry, Damien
2016-11-01
To compare three widely used methods for myocardial infarct (MI) sizing on late gadolinium-enhanced (LGE) magnetic resonance (MR) images: manual delineation and two semiautomated techniques (full-width at half-maximum [FWHM] and n-standard deviation [SD]). 3T phase-sensitive inversion-recovery (PSIR) LGE images of 114 patients after an acute MI (2-4 days and 6 months) were analyzed by two independent observers to determine both total and core infarct sizes (TIS/CIS). Manual delineation served as the reference for determination of optimal thresholds for semiautomated methods after thresholding at multiple values. Reproducibility and accuracy were expressed as overall bias ± 95% limits of agreement. Mean infarct sizes by manual methods were 39.0%/24.4% for the acute MI group (TIS/CIS) and 29.7%/17.3% for the chronic MI group. The optimal thresholds (ie, providing the closest mean value to the manual method) were FWHM30% and 3SD for the TIS measurement and FWHM45% and 6SD for the CIS measurement (paired t-test; all P > 0.05). The best reproducibility was obtained using FWHM. For TIS measurement in the acute MI group, intra-/interobserver agreements, from Bland-Altman analysis, with FWHM30%, 3SD, and manual were -0.02 ± 7.74%/-0.74 ± 5.52%, 0.31 ± 9.78%/2.96 ± 16.62% and -2.12 ± 8.86%/0.18 ± 16.12, respectively; in the chronic MI group, the corresponding values were 0.23 ± 3.5%/-2.28 ± 15.06, -0.29 ± 10.46%/3.12 ± 13.06% and 1.68 ± 6.52%/-2.88 ± 9.62%, respectively. A similar trend for reproducibility was obtained for CIS measurement. However, semiautomated methods produced inconsistent results (variabilities of 24-46%) compared to manual delineation. The FWHM technique was the most reproducible method for infarct sizing both in acute and chronic MI. However, both FWHM and n-SD methods showed limited accuracy compared to manual delineation. J. Magn. Reson. Imaging 2016;44:1206-1217. © 2016 International Society for Magnetic Resonance in Medicine.
Antipodal hotspot pairs on the earth
NASA Technical Reports Server (NTRS)
Rampino, Michael R.; Caldeira, Ken
1992-01-01
The results of statistical analyses performed on three published hotspot distributions suggest that significantly more hotspots occur as nearly antipodal pairs than is anticipated from a random distribution, or from their association with geoid highs and divergent plate margins. The observed number of antipodal hotspot pairs depends on the maximum allowable deviation from exact antipodality. At a maximum deviation of not greater than 700 km, 26 to 37 percent of hotspots form antipodal pairs in the published lists examined here, significantly more than would be expected from the general hotspot distribution. Two possible mechanisms that might create such a distribution include: (1) symmetry in the generation of mantle plumes, and (2) melting related to antipodal focusing of seismic energy from large-body impacts.
Perception of midline deviations in smile esthetics by laypersons
Ferreira, Jamille Barros; da Silva, Licínio Esmeraldo; Caetano, Márcia Tereza de Oliveira; da Motta, Andrea Fonseca Jardim; Cury-Saramago, Adriana de Alcantara; Mucha, José Nelson
2016-01-01
ABSTRACT Objective: To evaluate the esthetic perception of upper dental midline deviation by laypersons and if adjacent structures influence their judgment. Methods: An album with 12 randomly distributed frontal view photographs of the smile of a woman with the midline digitally deviated was evaluated by 95 laypersons. The frontal view smiling photograph was modified to create from 1 mm to 5 mm deviations in the upper midline to the left side. The photographs were cropped in two different manners and divided into two groups of six photographs each: group LCN included the lips, chin, and two-thirds of the nose, and group L included the lips only. The laypersons performed the rate of each smile using a visual analog scale (VAS). Wilcoxon test, Student’s t-test and Mann-Whitney test were applied, adopting a 5% level of significance. Results: Laypersons were able to perceive midline deviations starting at 1 mm. Statistically significant results (p< 0.05) were found for all multiple comparisons of the values in photographs of group LCN and for almost all comparisons in photographs of group L. Comparisons between the photographs of groups LCN and L showed statistically significant values (p< 0.05) when the deviation was 1 mm. Conclusions: Laypersons were able to perceive the upper dental midline deviations of 1 mm, and above when the adjacent structures of the smiles were included. Deviations of 2 mm and above when the lips only were included. The visualization of structures adjacent to the smile demonstrated influence on the perception of midline deviation. PMID:28125140
A critical assessment of two types of personal UV dosimeters.
Seckmeyer, Gunther; Klingebiel, Marcus; Riechelmann, Stefan; Lohse, Insa; McKenzie, Richard L; Liley, J Ben; Allen, Martin W; Siani, Anna-Maria; Casale, Giuseppe R
2012-01-01
Doses of erythemally weighted irradiances derived from polysulphone (PS) and electronic ultraviolet (EUV) dosimeters have been compared with measurements obtained using a reference spectroradiometer. PS dosimeters showed mean absolute deviations of 26% with a maximum deviation of 44%, the calibrated EUV dosimeters showed mean absolute deviations of 15% (maximum 33%) around noon during several test days in the northern hemisphere autumn. In the case of EUV dosimeters, measurements with various cut-off filters showed that part of the deviation from the CIE erythema action spectrum was due to a small, but significant sensitivity to visible radiation that varies between devices and which may be avoided by careful preselection. Usually the method of calibrating UV sensors by direct comparison to a reference instrument leads to reliable results. However, in some circumstances the quality of measurements made with simple sensors may be over-estimated. In the extreme case, a simple pyranometer can be used as a UV instrument, providing acceptable results for cloudless skies, but very poor results under cloudy conditions. It is concluded that while UV dosimeters are useful for their design purpose, namely to estimate personal UV exposures, they should not be regarded as an inexpensive replacement for meteorological grade instruments. © 2011 Wiley Periodicals, Inc. Photochemistry and Photobiology © 2011 The American Society of Photobiology.
Electronic properties of prismatic modifications of single-wall carbon nanotubes
NASA Astrophysics Data System (ADS)
Tomilin, O. B.; Muryumin, E. E.; Rodionova, E. V.; Ryskina, N. P.
2018-01-01
The article shows the possibility of target modifying the prismatic single-walled carbon nanotubes (SWCNTs) by regular chemisorption of fluorine atoms in the graphene surface. It is shown that the electronic properties of prismatic SWCNT modifications are determined by the interaction of π- and ρ(in-plane)-electron conjugation in the carbon-conjugated subsystems (tracks) formed in the faces. The contributions of π- and ρ(in-plane)-electron conjugation depend on the structural characteristics of the tracks. It was found that the minimum of degree deviation of the track from the plane of the prism face and the maximum of the track width ensure the maximum contribution of the π-electron conjugation, and the band gap of the prismatic modifications of the SWCNT tends to the band gap of the hydrocarbon analog of the carbon track. It is established that the maximum of degree deviation of the track from the plane of the prism face and the maximum of track width ensure the maximum contribution of the ρ(in-plane) electron interface, and the band gap of the prismatic modifications of the SWCNT tends to the band gap of the unmodified carbon nanotube. The calculation of the model systems has been carried out using an ab initio Hartree-Fock method in the 3-21G basis.
The mare: a 1000-pound guinea pig for study of the ovulatory follicular wave in women.
Ginther, O J
2012-03-15
The mare is a good comparative model for study of ovarian follicles in women, owing to striking similarities in follicular waves and the mechanism for selection of a dominant follicle. Commonality in follicle dynamics between mares and women include: (1) a ratio of 2.2:1 (mare:woman) in diameter of the largest follicle at wave emergence when the wave-stimulating FSH surge reaches maximum, in diameter increase of the two largest follicles between emergence and the beginning of deviation between the future dominant and subordinate follicles, in diameter of each of the two largest follicles at the beginning of deviation, and in maximum diameter of the preovulatory follicle; (2) emergence of the future ovulatory follicle before the largest subordinate follicle; (3) a mean interval of 1 day between emergence of individual follicles of the wave; (4) percentage increase in diameter of follicles for the 3 days before deviation; (5) deviation 3 or 4 days after emergence; (6) 25% incidence of a major anovulatory follicular wave emerging before the ovulatory wave; (7) 40% incidence of a predeviation follicle preceding the ovulatory wave; (8) small but significant increase in estradiol and LH before deviation; (9) cooperative roles of FSH and insulin-like growth factor 1 and its proteases in the deviation process; (10) age-related effects on the follicles and oocytes; (11) approximate 37-hour interval between administration of hCG and ovulation; and (12) similar gray-scale and color-Doppler ultrasound changes in the preovulatory follicle. In conclusion, the mare may be the premier nonprimate model for study of follicle dynamics in women. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Mohammadian, Shahabeddin K.; Rassoulinejad-Mousavi, Seyed Moein; Zhang, Yuwen
2015-11-01
Effect of embedding aluminum porous metal foam inside the flow channels of an air-cooled Li-ion battery module was studied to improve its thermal management. Four different cases of metal foam insert were examined using three-dimensional transient numerical simulations. The effects of permeability and porosity of the porous medium as well as state of charge were investigated on the standard deviation of the temperature field and maximum temperature inside the battery in all four cases. Compared to the case of no porous insert, embedding aluminum metal foam in the air flow channel significantly improved the thermal management of Li-ion battery cell. The results also indicated that, decreasing the porosity of the porous structure decreases both standard deviation of the temperature field and maximum temperature inside the battery. Moreover, increasing the permeability of the metal foam drops the maximum temperature inside the battery while decreasing this property leads to improving the temperature uniformity. Our results suggested that, among the all studied cases, desirable temperature uniformity and maximum temperature were achieved when two-third and the entire air flow channel is filled with aluminum metal foam, respectively.
Assessment of corneal epithelial thickness in dry eye patients.
Cui, Xinhan; Hong, Jiaxu; Wang, Fei; Deng, Sophie X; Yang, Yujing; Zhu, Xiaoyu; Wu, Dan; Zhao, Yujin; Xu, Jianjiang
2014-12-01
To investigate the features of corneal epithelial thickness topography with Fourier-domain optical coherence tomography (OCT) in dry eye patients. In this cross-sectional study, 100 symptomatic dry eye patients and 35 normal subjects were enrolled. All participants answered the ocular surface disease index questionnaire and were subjected to OCT, corneal fluorescein staining, tear breakup time, Schirmer 1 test without anesthetic (S1t), and meibomian morphology. Several epithelium statistics for each eye, including central, superior, inferior, minimum, maximum, minimum - maximum, and map standard deviation, were averaged. Correlations of epithelial thickness with the symptoms of dry eye were calculated. The mean (±SD) central, superior, and inferior corneal epithelial thickness was 53.57 (±3.31) μm, 52.00 (±3.39) μm, and 53.03 (±3.67) μm in normal eyes and 52.71 (±2.83) μm, 50.58 (±3.44) μm, and 52.53 (±3.36) μm in dry eyes, respectively. The superior corneal epithelium was thinner in dry eye patients compared with normal subjects (p = 0.037), whereas central and inferior epithelium were not statistically different. In the dry eye group, patients with higher severity grades had thinner superior (p = 0.017) and minimum (p < 0.001) epithelial thickness, more wide range (p = 0.032), and greater deviation (p = 0.003). The average central epithelial thickness had no correlation with tear breakup time, S1t, or the severity of meibomian glands, whereas average superior epithelial thickness positively correlated with S1t (r = 0.238, p = 0.017). Fourier-domain OCT demonstrated that the thickness map of the dry eye corneal epithelium was thinner than normal eyes in the superior region. In more severe dry eye disease patients, the superior and minimum epithelium was much thinner, with a greater range of map standard deviation.
NASA Technical Reports Server (NTRS)
Schlosser, Herbert
1992-01-01
In this note we present two expressions relating the cohesive energy, E(sub coh), and the zero pressure isothermal bulk modulus, B(sub 0), of the alkali halides. Ag halides and TI halides, with the nearest neighbor distances, d(sub nn). First, we show that the product E(sub coh)d(sub 0) within families of halide crystals with common crystal structure is to a good approximation constant, with maximum rms deviation of plus or minus 2%. Secondly, we demonstrate that within families of halide crystals with a common cation and common crystal structure the product B(sub 0)d(sup 3.5)(sub nn) is a good approximation constant, with maximum rms deviation of plus or minus 1.36%.
Zebrowska, A; Gawlik, K; Zwierzchowska, A
2007-11-01
The objective of the study was to investigate whether a sensory impairment has an effect on functional capabilities of the respiratory system and whether possible deviations from reference ranges of selected parameters might indicate a decrease of physical efficiency. Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), peak expiratory flow (PEF), forced expiratory flow of 25-75% (FEF25-75), maximum voluntary volume (MVV), and maximum oxygen uptake VO2 max were measured in 86 deaf and 102 blind children and adolescents, and in a matched group of hearing controls. We found a significant influence of deafness on PEF (P<0.01), FEF25-75 (P<0.05), and MVV (P<0.05). As compared with the control subjects, mean VC was significantly lower in blind adolescents (P<0.05). Our results seem to suggest that both sensory defects during childhood and adolescence affect functional capabilities of the respiratory system.
Normal and pathological serum levels of alpha2-macroglobulins in men and mice.
Tunstall, A M; Merriman, J M; Milne, I; James, K
1975-01-01
The serum levels of alpha2-macroglobulin have been measured in normal men and mice and in a number of immunopathological conditions. Normal human concentrations are high in youth, reach their minimum in middle age, and gradually increase with old age. In all age groups the mean is higher in the female than in the male. Conversely, in normal mice the alpha2M level is low in youth, maximum in middle age, and shows a slight depression with old age, and the levels are frequently higher in males than in females; there are also strain variations. In human immunopathological conditions, there are some deviations from the normal alpha2M level but these are seen to be changes from the normal distribution of values around the mean, rather than significant elevation or depression of mean values. In some disease states studied there are differences between the sexes in the deviation from normal. "Abnormal" strains of mice had alpha2M levels within the range exhibited by "normal" mice but changes in the levels are seen in mice with various myelomas. Images PMID:47865
Ionosphere Threat Model Investigations by Using Turkish National Permanent GPS Network
NASA Astrophysics Data System (ADS)
Köroǧlu, Meltem; Arikan, Feza; Koroglu, Ozan
2016-07-01
Global Positioning System (GPS) signal realibity may decrease significantly due to the variable electron density structure of ionosphere. In the literature, ionospheric disturbance is modeled as a linear semi-definite wave which has width, gradient and a constant velocity. To provide precise positioning, Ground Based Augmentation Systems (GBAS) are used. GBAS collects all measurements from GPS network receivers and computes an integrity level for the measurement by comparing the network GPS receivers measurements with the threat models of ionosphere. Threat models are computed according to ionosphere gradient characteristics. Gradient is defined as the difference of slant delays between the receivers. Slant delays are estimated from the STEC (Slant Total Electron Content) values of the ionosphere that is given by the line integral of the electron density between the receiver and GPS satellite. STEC can be estimated over Global Navigation Satellite System (GNSS) signals by using IONOLAB-STEC and IONOLAB-BIAS algorithms. Since most of the ionospheric disturbance observed locally, threat models for the GBAS systems must be extracted as locally. In this study, an automated ionosphere gradient estimation algorithm was developed by using Turkish National Permanent GPS Network (TNPGN-Active) data for year 2011. The GPS receivers are grouped within 150 km radius. For each region, for each day and for each satellite all STEC values are estimated by using IONOLAB-STEC and IONOLAB-BIAS softwares (www.ionolab.org). In the gradient estimation, station-pair method is used. Statistical properties of the valid gradients are extracted as tables for each region, day and satellite. By observing the histograms of the maximum gradients and standard deviations of the gradients with respect to the elevation angle for each day, the anomalies and disturbances of the ionosphere can be detected. It is observed that, maximum gradient estimates are less than 40 mm/km and maximum standard deviation of the gradients are observed as 5 mm/km. In the stormy days, the level of gradients and the standard deviation values becomes larger than those of quiet days. These observations may also form a basis for the estimationof velocity and width of the traveling ionospheric disturbances. The study is supported by TUBITAK 115E915 and Joint TUBITAK 114E092 and AS CR14/001 projects.
Green, Nancy S; Manwani, Deepa; Qureshi, Mahvish; Ireland, Karen; Sinha, Arpan; Smaldone, Arlene M
2016-12-01
Hydroxyurea (HU) induces dose-dependent increased fetal hemoglobin (HbF) for sickle cell disease (SCD). Large deviation from historical personal best (PBest) HbF, a clinic-based version of maximum dose, may identify a subset with suboptimal HU adherence over time. Retrospective clinical data from youth ages 10-18 years prescribed HU at two centers were extracted from medical records at three time points: pre-HU initiation, PBest and a recent assessment. Decrease from PBest HbF of 20% or more at recent assessment despite stable dosing was designated as high deviation from PBest. Acute hospital use was compared between 1-year periods, pre-HU and ±6 months for PBest and recent assessment. Groups were compared using descriptive and bivariate nonparametric statistics. Seventy-five youth, mean HU duration 5.9 years, met eligibility criteria. Mean ages of HU initiation, PBest and recent assessment were 8.0, 10.9 and 13.9 years, respectively. Despite stable dosing, average HbF of 19.5% at PBest overall declined by 31.8% at recent assessment. PBest HbF declined by 11.7 and 40.1% in two groups, the latter comprised 70.7% of the sample, had lower pre-HU and recent HbF and higher dosing. They experienced more urgent hospital use during the year framing recent assessment than during PBest; these findings were supported by sensitivity analysis. Decline from PBest HbF is a novel approach to assess HU effectiveness, is common among youth and may represent suboptimal adherence. Larger prospective studies using additional adherence measures are needed to confirm our approach of tracking HbF deviation over time and to define an appropriate cutoff. © 2016 Wiley Periodicals, Inc.
Ozone trends and their relationship to characteristic weather patterns.
Austin, Elena; Zanobetti, Antonella; Coull, Brent; Schwartz, Joel; Gold, Diane R; Koutrakis, Petros
2015-01-01
Local trends in ozone concentration may differ by meteorological conditions. Furthermore, the trends occurring at the extremes of the Ozone distribution are often not reported even though these may be very different than the trend observed at the mean or median and they may be more relevant to health outcomes. Classify days of observation over a 16-year period into broad categories that capture salient daily local weather characteristics. Determine the rate of change in mean and median O3 concentrations within these different categories to assess how concentration trends are impacted by daily weather. Further examine if trends vary for observations in the extremes of the O3 distribution. We used k-means clustering to categorize days of observation based on the maximum daily temperature, standard deviation of daily temperature, mean daily ground level wind speed, mean daily water vapor pressure and mean daily sea-level barometric pressure. The five cluster solution was determined to be the appropriate one based on cluster diagnostics and cluster interpretability. Trends in cluster frequency and pollution trends within clusters were modeled using Poisson regression with penalized splines as well as quantile regression. There were five characteristic groupings identified. The frequency of days with large standard deviations in hourly temperature decreased over the observation period, whereas the frequency of warmer days with smaller deviations in temperature increased. O3 trends were significantly different within the different weather groupings. Furthermore, the rate of O3 change for the 95th percentile and 5th percentile was significantly different than the rate of change of the median for several of the weather categories.We found that O3 trends vary between different characteristic local weather patterns. O3 trends were significantly different between the different weather groupings suggesting an important interaction between changes in prevailing weather conditions and O3 concentration.
ALTERED PHALANX FORCE DIRECTION DURING POWER GRIP FOLLOWING STROKE
Enders, Leah R.
2015-01-01
Many stroke survivors with severe impairment can grasp only with a power grip. Yet, little knowledge is available on altered power grip after stroke, other than reduced power grip strength. This study characterized stroke survivors’ static power grip during 100% and 50% maximum grip. Each phalanx force’s angular deviation from the normal direction and its contribution to total normal force was compared for 11 stroke survivors and 11 age-matched controls. Muscle activities and skin coefficient of friction (COF) were additionally compared for another 20 stroke and 13 age-matched control subjects. The main finding was that stroke survivors gripped with a 34% greater phalanx force angular deviation of 19±2° compared to controls of 14±1° (p<.05). Stroke survivors’ phalanx force angular deviation was closer to the 23° threshold of slippage between the phalanx and grip surface, which may explain increased likelihood of object dropping in stroke survivors. In addition, this altered phalanx force direction decreases normal grip force by tilting the force vector, indicating a partial role of phalanx force angular deviation in reduced grip strength post stroke. Greater phalanx force angular deviation may biomechanically result from more severe underactivation of stroke survivors’ first dorsal interosseous (FDI) and extensor digitorum communis (EDC) muscles compared to their flexor digitorum superficialis (FDS) or somatosensory deficit. While stroke survivors’ maximum power grip strength was approximately half of the controls’, the distribution of their remaining strength over the fingers and phalanges did not differ, indicating evenly distributed grip force reduction over the entire hand. PMID:25795079
Schroeder, A A; Ford, N L; Coil, J M
2017-03-01
To determine whether post space preparation deviated from the root canal preparation in canals filled with Thermafil, GuttaCore or warm vertically compacted gutta-percha. Forty-two extracted human permanent maxillary lateral incisors were decoronated, and their root canals instrumented using a standardized protocol. Samples were divided into three groups and filled with Thermafil (Dentsply Tulsa Dental Specialties, Johnson City, TN, USA), GuttaCore (Dentsply Tulsa Dental Specialties) or warm vertically compacted gutta-percha, before post space preparation was performed with a GT Post drill (Dentsply Tulsa Dental Specialties). Teeth were scanned using micro-computed tomography after root filling and again after post space preparation. Scans were examined for number of samples with post space deviation, linear deviation of post space preparation and minimum root thickness before and after post space preparation. Parametric data were analysed with one-way analysis of variance (anova) or one-tailed paired Student's t-tests, whilst nonparametric data were analysed with Fisher's exact test. Deviation occurred in eight of forty-two teeth (19%), seven of fourteen from the Thermafil group (50%), one of fourteen from the GuttaCore group (7%), and none from the gutta-percha group. Deviation occurred significantly more often in the Thermafil group than in each of the other two groups (P < 0.05). Linear deviation of post space preparation was greater in the Thermafil group than in both of the other groups and was significantly greater than that of the gutta-percha group (P < 0.05). Minimum root thickness before post space preparation was significantly greater than it was after post space preparation for all groups (P < 0.01). The differences between the Thermafil, GuttaCore and gutta-percha groups in the number of samples with post space deviation and in linear deviation of post space preparation were associated with the presence or absence of a carrier as well as the different carrier materials. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
The response of ionization chambers to relativistic heavy nuclei
NASA Technical Reports Server (NTRS)
Newport, B. J.; Stone, E. C.; Waddington, C. J.; Binns, W. R.; Fixsen, D. J.; Garrard, T. L.; Grimm, G.; Israel, M. H.; Klarmann, J.
1985-01-01
The LBL Bevalac for the Heavy Nuclei Experiment on HEAO-3, compared the response of a set of laboratory ionization chambers to beams of 26Fe, 36Kr, 54Xe, 67 Ho, and 79Au nuclei at maximum energies ranging from 1666 MeV/amu for Fe to 1049 MeV/amu for Au. The response of these chambers shows a significant deviation from the expected energy dependence, but only a slight deviation from Z sq scaling.
Spatial variability in airborne pollen concentrations.
Raynor, G S; Ogden, E C; Hayes, J V
1975-03-01
Tests were conducted to determine the relationship between airborne pollen concentrations and distance. Simultaneous samples were taken in 171 tests with sets of eight rotoslide samplers spaced from one to 486 M. apart in straight lines. Use of all possible pairs gave 28 separation distances. Tests were conducted over a 2-year period in urban and rural locations distant from major pollen sources during both tree and ragweed pollen seasons. Samples were taken at a height of 1.5 M. during 5-to 20-minute periods. Tests were grouped by pollen type, location, year, and direction of the wind relative to the line. Data were analyzed to evaluate variability without regard to sampler spacing and variability as a function of separation distance. The mean, standard deviation, coefficient of variation, ratio of maximum to the mean, and ratio of minimum to the mean were calculated for each test, each group of tests, and all cases. The average coefficient of variation is 0.21, the maximum over the mean, 1.39 and the minimum over the mean, 0.69. No relationship was found with experimental conditions. Samples taken at the minimum separation distance had a mean difference of 18 per cent. Differences between pairs of samples increased with distance in 10 of 13 groups. These results suggest that airborne pollens are not always well mixed in the lower atmosphere and that a sample becomes less representative with increasing distance from the sampling location.
NASA Astrophysics Data System (ADS)
Lee, H.; Sheen, D.; Kim, S.
2013-12-01
The b-value in Gutenberg-Richter relation is an important parameter widely used not only in the interpretation of regional tectonic structure but in the seismic hazard analysis. In this study, we tested four methods for estimating the stable b-value in a small number of events using Monte-Carlo method. One is the Least-Squares method (LSM) which minimizes the observation error. Others are based on the Maximum Likelihood method (MLM) which maximizes the likelihood function: Utsu's (1965) method for continuous magnitudes and an infinite maximum magnitude, Page's (1968) for continuous magnitudes and a finite maximum magnitude, and Weichert's (1980) for interval magnitude and a finite maximum magnitude. A synthetic parent population of the earthquake catalog of million events from magnitude 2.0 to 7.0 with interval of 0.1 was generated for the Monte-Carlo simulation. The sample, the number of which was increased from 25 to 1000, was extracted from the parent population randomly. The resampling procedure was applied 1000 times with different random seed numbers. The mean and the standard deviation of the b-value were estimated for each sample group that has the same number of samples. As expected, the more samples were used, the more stable b-value was obtained. However, in a small number of events, the LSM gave generally low b-value with a large standard deviation while other MLMs gave more accurate and stable values. It was found that Utsu (1965) gives the most accurate and stable b-value even in a small number of events. It was also found that the selection of the minimum magnitude could be critical for estimating the correct b-value for Utsu's (1965) method and Page's (1968) if magnitudes were binned into an interval. Therefore, we applied Utsu (1965) to estimate the b-value using two instrumental earthquake catalogs, which have events occurred around the southern part of the Korean Peninsula from 1978 to 2011. By a careful choice of the minimum magnitude, the b-values of the earthquake catalogs of the Korea Meteorological Administration and Kim (2012) are estimated to be 0.72 and 0.74, respectively.
Effect of nasal deviation on quality of life.
de Lima Ramos, Sueli; Hochman, Bernardo; Gomes, Heitor Carvalho; Abla, Luiz Eduardo Felipe; Veiga, Daniela Francescato; Juliano, Yara; Dini, Gal Moreira; Ferreira, Lydia Masako
2011-07-01
Nasal deviation is a common complaint in otorhinolaryngology and plastic surgery. This condition not only causes impairment of nasal function but also affects quality of life, leading to psychological distress. The subjective assessment of quality of life, as an important aspect of outcomes research, has received increasing attention in recent decades. Quality of life is measured using standardized questionnaires that have been tested for reliability, validity, and sensitivity. The aim of this study was to evaluate health-related quality of life, self-esteem, and depression in patients with nasal deviation. Sixty patients were selected for the study. Patients with nasal deviation (n = 32) were assigned to the study group, and patients without nasal deviation (n = 28) were assigned to the control group. The diagnosis of nasal deviation was made by digital photogrammetry. Quality of life was assessed using the Medical Outcomes Study 36-Item Short Form Health Survey questionnaire; the Rosenberg Self-Esteem/Federal University of São Paulo, Escola Paulista de Medicina Scale; and the 20-item Self-Report Questionnaire. There were significant differences between groups in the physical functioning and general health subscales of the Medical Outcomes Study 36-Item Short Form Health Survey (p < 0.05). Depression was detected in 11 patients (34.4 percent) in the study group and in two patients in the control group, with a significant difference between groups (p < 0.05). Nasal deviation is an aspect of rhinoplasty of which the surgeon should be aware so that proper psychological diagnosis can be made and suitable treatment can be planned because psychologically the patients with nasal deviation have significantly worse quality of life and are more prone to depression. Risk, II.(Figure is included in full-text article.).
Raymond, Elizabeth G; Weaver, Mark A; Louie, Karmen S; Dean, Gillian; Porsch, Lauren; Lichtenberg, E Steve; Ali, Rose; Arnesen, Michelle
2013-09-01
To compare the effectiveness of two oral analgesic regimens in first-trimester medical abortion. We randomly assigned 250 participants undergoing first-trimester abortion with mifepristone and misoprostol at three clinics to two ibuprofen regimens: therapeutic (800 mg every 4-6 hours as needed for pain) or prophylactic (800 mg starting 1 hour before the misoprostol dose, then every 4-6 hours for 48 hours regardless of pain, then as needed). We asked each participant to record her maximum pain on a scale of 0-10 daily thereafter. Of participants assigned to the prophylactic and therapeutic regimens, 111 of 123 (90%) and 117 of 127 (92%), respectively, provided follow-up data. More than 80% of the participants in each group complied with their assigned treatment. Participants in the prophylactic group used substantially more ibuprofen than those in the therapeutic group (median of nine and four tablets, respectively). The mean maximum pain score was 7.1 in the prophylactic group and 7.3 in the therapeutic group (standard deviations 2.5 and 2.2, respectively); the difference was not statistically significant (P=.87, adjusted for site). Duration of pain, verbal pain ratings reported at follow-up, and use of other analgesics did not differ significantly by group (all P>.05). No significant benefit of the prophylactic regimen was apparent in any population subgroup. Abortion failure and ibuprofen side effects in the two groups were similar. We found no evidence that prophylactic administration of ibuprofen reduces pain severity or duration in first-trimester medical abortion. The average pain severity experienced by participants using both regimens was high. ClinicalTrials.gov, www.clinicaltrials.gov, NCT01457521. I.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1978-10-03
This report is a six-part statistical summary of surface weather observations for Torrejon AB, Madrid Spain. It contains the following parts: (A) Weather Conditions; Atmospheric Phenomena; (B) Precipitation, Snowfall and Snow Depth (daily amounts and extreme values); (C) Surface winds; (D) Ceiling Versus Visibility; Sky Cover; (E) Psychrometric Summaries (daily maximum and minimum temperatures, extreme maximum and minimum temperatures, psychrometric summary of wet-bulb temperature depression versus dry-bulb temperature, means and standard deviations of dry-bulb, wet-bulb and dew-point temperatures and relative humidity); and (F) Pressure Summary (means, standard, deviations, and observation counts of station pressure and sea-level pressure). Data in thismore » report are presented in tabular form, in most cases in percentage frequency of occurrence or cumulative percentage frequency of occurrence tables.« less
Roberts, Graham J; McDonald, Fraser; Andiappan, Manoharan; Lucas, Victoria S
2015-11-01
The final stage of dental development of third molars is usually helpful to indicate whether or not a subject is aged over 18 years. A complexity is that the final stage of development is unlimited in its upper border. Investigators usually select an inappropriate upper age limit or censor point for this tooth development stage. The literature was searched for appropriate data sets for dental age estimation and those that provided the count (n), the mean (x¯), and the standard deviation (sd) for each of the tooth development stages. The Demirjian G and Demirjian H were used for this study. Upper and lower limits of the Stage G and Stage H data were calculated limiting the data to plus or minus three standard deviations from the mean. The upper border of Stage H was limited by appropriate censoring at the maximum value for Stage G. The maximum age at attainment from published data, for Stage H, ranged from 22.60 years to 34.50 years. These data were explored to demonstrate how censoring provides an estimate for the correct maximum age for the final stage of Stage H as 21.64 years for UK Caucasians. This study shows that confining the data array of individual tooth developments stages to ± 3sd provides a reliable and logical way of censoring the data for tooth development stages with a Normal distribution of data. For Stage H this is inappropriate as it is unbounded in its upper limit. The use of a censored data array for Stage H using Percentile values is appropriate. This increases the reliability of using third molar Stage H alone to determine whether or not an individual is over 18 years old. For Stage H, individual ancestral groups should be censored using the same technique. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
The response of ionization chambers to relativistic heavy nuclei
NASA Technical Reports Server (NTRS)
Newport, B. J.; Stone, E. C.; Waddington, C. J.; Binns, W. R.; Fixsen, D. J.; Garrard, T. L.; Grimm, G.; Israel, M. H.; Klarmann, J.
1985-01-01
As part of a recent calibration at the LBL Bevalac for the Heavy Nuclei Experiment on HEAO-3, the response of a set of laboratory ionization chambers were compared to beams of 26Fe, 36 Kr, 54Xe, 67 Ho, and 79 Au nuclei at maximum energies ranging from 1666 MeV/amu for Fe to 1049 MeV/amu for Au. The response of these chambers shows a significant deviation from the expected energy dependence, but only a slight deviation from Z squared scaling.
Chen, Guang; Das, Siddhartha
2017-03-01
In this paper, we study the thermodynamics, electrostatics, and an external electric field driven ionic current in a pH-responsive, end-charged polyelectrolyte (PE) brush grafted nanochannel. By employing a mean field theory, we unravel a highly nonintuitive interplay of pH and electrolyte salt concentration in dictating the height of the end-charged PE brush. Larger pH or weak hydrogen ion concentration leads to maximum ionization of the charge-producing group-as a consequence, the resulting the electric double layer (EDL) energy get maximized causing a maximum deviation of the brush height from the value (d 0 ) of the uncharged brush. This deviation may result in enhancement or lowering of the brush height as compared to d 0 depending on whether the PE end locates lower or higher than h/2 (h is the nanochannel half height) and the salt concentration. Subsequently, we use this combined PE-brush-configuration-EDL-electrostatics framework to compute the ionic current in the nanochannel. We witness that the ionic current for smaller pH is much larger despite the corresponding magnitude of the EDL electrostatic potential being much smaller-this stems from the presence of a much larger concentration of H+ ions at small pH and the fact that H+ ions have very large mobilities. In fact, this ionic current shows a steep variation with pH that can be useful in exploring new designs for applications involving quantification and characterization of ionic current in PE-brush-grafted nanochannels. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Experimental and numerical investigations of temporally and spatially periodic modulated wave trains
NASA Astrophysics Data System (ADS)
Houtani, H.; Waseda, T.; Tanizawa, K.
2018-03-01
A number of studies on steep nonlinear waves were conducted experimentally with the temporally periodic and spatially evolving (TPSE) wave trains and numerically with the spatially periodic and temporally evolving (SPTE) ones. The present study revealed that, in the vicinity of their maximum crest height, the wave profiles of TPSE and SPTE modulated wave trains resemble each other. From the investigation of the Akhmediev-breather solution of the nonlinear Schrödinger equation (NLSE), it is revealed that the dispersion relation deviated from the quadratic dependence of frequency on wavenumber and became linearly dependent instead. Accordingly, the wave profiles of TPSE and SPTE breathers agree. The range of this agreement is within the order of one wave group of the maximum crest height and persists during the long-term evolution. The findings extend well beyond the NLSE regime and can be applied to modulated wave trains that are highly nonlinear and broad-banded. This was demonstrated from the numerical wave tank simulations with a fully nonlinear potential flow solver based on the boundary element method, in combination with the nonlinear wave generation method based on the prior simulation with the higher-order spectral model. The numerical wave tank results were confirmed experimentally in a physical wave tank. The findings of this study unravel the fundamental nature of the nonlinear wave evolution. The deviation of the dispersion relation of the modulated wave trains occurs because of the nonlinear phase variation due to quasi-resonant interaction, and consequently, the wave geometry of temporally and spatially periodic modulated wave trains coincides.
Artmann, L; Larsen, H J; Sørensen, H B; Christensen, I J; Kjaer, I
2010-06-01
To analyze the interrelationship between incisor width, deviations in the dentition and available space in the dental arch in palatally and labially located maxillary ectopic canine cases. Size: On dental casts from 69 patients (mean age 13 years 6 months) the mesiodistal widths of each premolar, canine and incisor were measured and compared with normal standards. Dental deviations: Based on panoramic radiographs from the same patients the dentitions were grouped accordingly: Group I: normal morphology; Group IIa: deviations in the dentition within the maxillary incisors only; Group IIb: deviations in the dentition in general. Descriptive statistics for the tooth sizes and dental deviations were presented by the mean and 95% confidence limits for the mean and the p-value for the T-statistic. Space: Space was expresses by subtracting the total tooth sizes of incisors, canines and premolars from the length of the arch segments. Size of lateral maxillary incisor: The widths of the lateral incisors were significantly different in groups I, IIa and IIb (p=0.016) and in cases with labially located ectopic canines on average 0.65 (95% CI:0.25-1.05, p=0.0019) broader than lateral incisors in cases with palatally located ectopic canines. Space: Least available space was observed in cases with labially located canines. The linear model did show a difference between palatally and labially located ectopic canines (p=0.03). Space related to deviations in the dentition: When space in the dental arch was related to dental deviations (groups I, IIa and IIb), the cases in group IIb with palatally located canines had significantly more space compared with I and IIa. Two subgroups of palatally located ectopic maxillary canine cases based on registration of space, incisor width and deviations in the morphology of the dentition were identified.
EARLINET Single Calculus Chain - technical - Part 2: Calculation of optical products
NASA Astrophysics Data System (ADS)
Mattis, Ina; D'Amico, Giuseppe; Baars, Holger; Amodeo, Aldo; Madonna, Fabio; Iarlori, Marco
2016-07-01
In this paper we present the automated software tool ELDA (EARLINET Lidar Data Analyzer) for the retrieval of profiles of optical particle properties from lidar signals. This tool is one of the calculus modules of the EARLINET Single Calculus Chain (SCC) which allows for the analysis of the data of many different lidar systems of EARLINET in an automated, unsupervised way. ELDA delivers profiles of particle extinction coefficients from Raman signals as well as profiles of particle backscatter coefficients from combinations of Raman and elastic signals or from elastic signals only. Those analyses start from pre-processed signals which have already been corrected for background, range dependency and hardware specific effects. An expert group reviewed all algorithms and solutions for critical calculus subsystems which are used within EARLINET with respect to their applicability for automated retrievals. Those methods have been implemented in ELDA. Since the software was designed in a modular way, it is possible to add new or alternative methods in future. Most of the implemented algorithms are well known and well documented, but some methods have especially been developed for ELDA, e.g., automated vertical smoothing and temporal averaging or the handling of effective vertical resolution in the case of lidar ratio retrievals, or the merging of near-range and far-range products. The accuracy of the retrieved profiles was tested following the procedure of the EARLINET-ASOS algorithm inter-comparison exercise which is based on the analysis of synthetic signals. Mean deviations, mean relative deviations, and normalized root-mean-square deviations were calculated for all possible products and three height layers. In all cases, the deviations were clearly below the maximum allowed values according to the EARLINET quality requirements.
A New Online Calibration Method Based on Lord's Bias-Correction.
He, Yinhong; Chen, Ping; Li, Yong; Zhang, Shumei
2017-09-01
Online calibration technique has been widely employed to calibrate new items due to its advantages. Method A is the simplest online calibration method and has attracted many attentions from researchers recently. However, a key assumption of Method A is that it treats person-parameter estimates θ ^ s (obtained by maximum likelihood estimation [MLE]) as their true values θ s , thus the deviation of the estimated θ ^ s from their true values might yield inaccurate item calibration when the deviation is nonignorable. To improve the performance of Method A, a new method, MLE-LBCI-Method A, is proposed. This new method combines a modified Lord's bias-correction method (named as maximum likelihood estimation-Lord's bias-correction with iteration [MLE-LBCI]) with the original Method A in an effort to correct the deviation of θ ^ s which may adversely affect the item calibration precision. Two simulation studies were carried out to explore the performance of both MLE-LBCI and MLE-LBCI-Method A under several scenarios. Simulation results showed that MLE-LBCI could make a significant improvement over the ML ability estimates, and MLE-LBCI-Method A did outperform Method A in almost all experimental conditions.
Evaluation of methods for measuring particulate matter emissions from gas turbines.
Petzold, Andreas; Marsh, Richard; Johnson, Mark; Miller, Michael; Sevcenco, Yura; Delhaye, David; Ibrahim, Amir; Williams, Paul; Bauer, Heidi; Crayford, Andrew; Bachalo, William D; Raper, David
2011-04-15
The project SAMPLE evaluated methods for measuring particle properties in the exhaust of aircraft engines with respect to the development of standardized operation procedures for particulate matter measurement in aviation industry. Filter-based off-line mass methods included gravimetry and chemical analysis of carbonaceous species by combustion methods. Online mass methods were based on light absorption measurement or used size distribution measurements obtained from an electrical mobility analyzer approach. Number concentrations were determined using different condensation particle counters (CPC). Total mass from filter-based methods balanced gravimetric mass within 8% error. Carbonaceous matter accounted for 70% of gravimetric mass while the remaining 30% were attributed to hydrated sulfate and noncarbonaceous organic matter fractions. Online methods were closely correlated over the entire range of emission levels studied in the tests. Elemental carbon from combustion methods and black carbon from optical methods deviated by maximum 5% with respect to mass for low to medium emission levels, whereas for high emission levels a systematic deviation between online methods and filter based methods was found which is attributed to sampling effects. CPC based instruments proved highly reproducible for number concentration measurements with a maximum interinstrument standard deviation of 7.5%.
Improved thermal conductivity of TiO2-SiO2 hybrid nanofluid in ethylene glycol and water mixture
NASA Astrophysics Data System (ADS)
Hamid, K. A.; Azmi, W. H.; Nabil, M. F.; Mamat, R.
2017-10-01
The need to study hybrid nanofluid properties such as thermal conductivity has increased recently in order to provide better understanding on nanofluid thermal properties and behaviour. Due to its ability to improve heat transfer compared to conventional heat transfer fluids, nanofluids as a new coolant fluid are widely investigated. This paper presents the thermal conductivity of TiO2-SiO2 nanoparticles dispersed in ethylene glycol (EG)-water. The TiO2-SiO2 hybrid nanofluids is measured for its thermal conductivity using KD2 Pro Thermal Properties Analyzer for concentration ranging from 0.5% to 3.0% and temperature of 30, 50 and 70°C. The results show that the increasing in concentration and temperature lead to enhancement in thermal conductivity at range of concentration studied. The maximum enhancement is found to be 22.1% at concentration 3.0% and temperature 70°C. A new equation is proposed based on the experiment data and found to be in good agreement where the average deviation (AD), standard deviation (SD) and maximum deviation (MD) are 1.67%, 1.66% and 5.13%, respectively.
Maxwell, Susan K; Sylvester, Kenneth M
2012-06-01
A time series of 230 intra- and inter-annual Landsat Thematic Mapper images was used to identify land that was ever cropped during the years 1984 through 2010 for a five county region in southwestern Kansas. Annual maximum Normalized Difference Vegetation Index (NDVI) image composites (NDVI(ann-max)) were used to evaluate the inter-annual dynamics of cropped and non-cropped land. Three feature images were derived from the 27-year NDVI(ann-max) image time series and used in the classification: 1) maximum NDVI value that occurred over the entire 27 year time span (NDVI(max)), 2) standard deviation of the annual maximum NDVI values for all years (NDVI(sd)), and 3) standard deviation of the annual maximum NDVI values for years 1984-1986 (NDVI(sd84-86)) to improve Conservation Reserve Program land discrimination.Results of the classification were compared to three reference data sets: County-level USDA Census records (1982-2007) and two digital land cover maps (Kansas 2005 and USGS Trends Program maps (1986-2000)). Area of ever-cropped land for the five counties was on average 11.8 % higher than the area estimated from Census records. Overall agreement between the ever-cropped land map and the 2005 Kansas map was 91.9% and 97.2% for the Trends maps. Converting the intra-annual Landsat data set to a single annual maximum NDVI image composite considerably reduced the data set size, eliminated clouds and cloud-shadow affects, yet maintained information important for discriminating cropped land. Our results suggest that Landsat annual maximum NDVI image composites will be useful for characterizing land use and land cover change for many applications.
Clinical Implications of Septal Deviation in Lateralized Olfaction
Choi, Yoon-Seok; Ryu, Yoon-Jong; Rhee, Jihye; Seok, Jungirl; Han, Sungjun; Jin, Hong Ryul; Kim, Dae Woo
2016-01-01
Objectives Results of butanol threshold tests (BTTs) have shown that birhinal olfaction tends to converge toward monorhinal olfaction of the dominant nostril. However, birhinal olfaction may also be worse than dominant-side monorhinal olfaction. The goal of our study was to investigate the effect of deviated nasal septum on birhinal olfaction in patients with lateralized olfaction and to examine the effect of septoplasty in these patients. Methods A retrospective study with planned data collection was conducted in 518 patients who underwent BTTs. Lateralized olfaction was defined as monorhinal BTT scores that differed by >2 between sides. Underestimated birhinal olfaction was defined as a birhinal BTT score >2 lower than the dominant nostril monorhinal BTT score. Patients with lateralized olfaction were divided into 2 groups: group 1, underestimated birhinal olfaction; and group 2, without underestimated birhinal olfaction. Results Among 518 patients, 112 with lateralized olfaction were enrolled in this study. Group 1 included 23 patients (20.5%) and group 2 included 89 patients (79.5%). The severity of septal deviation (ratio of the distance of narrower side to wider side) did not differ between the 2 groups. Septal deviation to the dominant nostril was more common in group 1 than group 2 (73.9% vs. 37.6%; P=0.002). Five patients with septal deviation to the dominant nostril with underestimated birhinal olfaction underwent septoplasty. Improved lateralized olfaction occurred in all 5 patients postoperatively (P=0.041). Conclusion Septal deviation of the dominant nostril in patients with lateralized olfaction is associated with underestimated birhinal olfaction. Septoplasty may improve olfaction by increasing airflow in the dominant olfactory side. PMID:26976025
Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Sánchez-Labraca, Nuria; Quesada-Rubio, José Manuel; Granero-Molina, José; Moreno-Lorenzo, Carmen
2011-01-01
Fibromyalgia is a prevalent musculoskeletal disorder associated with widespread mechanical tenderness, fatigue, non-refreshing sleep, depressed mood and pervasive dysfunction of the autonomic nervous system: tachycardia, postural intolerance, Raynaud's phenomenon and diarrhoea. To determine the effects of craniosacral therapy on sensitive tender points and heart rate variability in patients with fibromyalgia. A randomized controlled trial. Ninety-two patients with fibromyalgia were randomly assigned to an intervention group or placebo group. Patients received treatments for 20 weeks. The intervention group underwent a craniosacral therapy protocol and the placebo group received sham treatment with disconnected magnetotherapy equipment. Pain intensity levels were determined by evaluating tender points, and heart rate variability was recorded by 24-hour Holter monitoring. After 20 weeks of treatment, the intervention group showed significant reduction in pain at 13 of the 18 tender points (P < 0.05). Significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement versus baseline values were observed in the intervention group but not in the placebo group. At two months and one year post therapy, the intervention group showed significant differences versus baseline in tender points at left occiput, left-side lower cervical, left epicondyle and left greater trochanter and significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement. Craniosacral therapy improved medium-term pain symptoms in patients with fibromyalgia.
Chandralekha, Kuppan; Gavaskar, Deivasigamani; Sureshbabu, Adukamparai Rajukrishnan; Lakshmi, Srinivasakannan
2014-09-01
In the title compound, [Fe(C5H5)(C34H28N3O)], the four-fused-rings system of the 11H-indeno-[1,2-b]quinoxaline unit is approximately planar [maximum deviation = 0.167 (4) Å] and forms a dihedral angle of 37.25 (6)° with the plane of the benzene ring of the methyl-benzoyl group. Both pyrrolidine rings adopt a twist conformation. An intra-molecular C-H⋯O hydrogen bond is observed. In the crystal, mol-ecules are linked by C-H⋯O hydrogen bonds and weak C-H⋯π inter-actions, forming double chains extending parallel to the c axis.
Altamimi, Abdulaziz M; Tripodakis, Aris Petros; Eliades, George; Hirayama, Hiroshi
2014-01-01
To compare the fracture resistance between bilayered zirconia/ fluorapatite and monolithic lithium disilicate heat-pressed crowns and characterize the mode of fracture failure. Thirty crown samples were sequentially fitted on a mandibular right first molar metal replica of an ivory prepared molar tooth. The crown specimens were divided in three groups (A, B, and C; n = 10 for each group). Group A consisted of bilayered zirconia/fluorhapatite pressed-over crowns with standard design crown copings (0.7 mm uniform thickness), Group B of bilayered zirconia/fluorhapatite with anatomical design crown copings, and Group C of lithium disilicate monolithic crowns. The samples were then dynamically loaded under water for 100,000 cycles with a profile of 250 N maximum load at 1,000 N/s rate and 2.0 Hz frequency. Loading was performed with a steel ball (5 mm in diameter) coming into contact with the test crown, loading to maximum, holding for 0.2 s, unloading and lifting off 0.5 mm. The samples were then fractured under static loading, in order to determine the ultimate crown strength. Analysis of the recorded fracture load values was carried out with one-way analysis of variance (ANOVA) followed by Tukey tests. Fractured specimens were examined by stereomicroscopy and scanning electron microscopy. The fracture loads measured were (N, means and standard deviations): Group A: 561.87 (72.63), Group B: 1,014.16 (70.18) and Group C: 1,360.63 (77.95). All mean differences were statistically significant (P < 0.001). Catastrophic fractures occurred in Group C, whereas mainly veneer fractures were observed in Groups A and B. In the present study, the heat-pressed monolithic lithium-disilicate crowns showed more fracture resistance than zirconia/fluorapatite pressed-over crowns. Within the bilayered groups, the anatomical zirconia coping design presented increased ceramic fracture resistance.
The Laplace method for probability measures in Banach spaces
NASA Astrophysics Data System (ADS)
Piterbarg, V. I.; Fatalov, V. R.
1995-12-01
Contents §1. Introduction Chapter I. Asymptotic analysis of continual integrals in Banach space, depending on a large parameter §2. The large deviation principle and logarithmic asymptotics of continual integrals §3. Exact asymptotics of Gaussian integrals in Banach spaces: the Laplace method 3.1. The Laplace method for Gaussian integrals taken over the whole Hilbert space: isolated minimum points ([167], I) 3.2. The Laplace method for Gaussian integrals in Hilbert space: the manifold of minimum points ([167], II) 3.3. The Laplace method for Gaussian integrals in Banach space ([90], [174], [176]) 3.4. Exact asymptotics of large deviations of Gaussian norms §4. The Laplace method for distributions of sums of independent random elements with values in Banach space 4.1. The case of a non-degenerate minimum point ([137], I) 4.2. A degenerate isolated minimum point and the manifold of minimum points ([137], II) §5. Further examples 5.1. The Laplace method for the local time functional of a Markov symmetric process ([217]) 5.2. The Laplace method for diffusion processes, a finite number of non-degenerate minimum points ([116]) 5.3. Asymptotics of large deviations for Brownian motion in the Hölder norm 5.4. Non-asymptotic expansion of a strong stable law in Hilbert space ([41]) Chapter II. The double sum method - a version of the Laplace method in the space of continuous functions §6. Pickands' method of double sums 6.1. General situations 6.2. Asymptotics of the distribution of the maximum of a Gaussian stationary process 6.3. Asymptotics of the probability of a large excursion of a Gaussian non-stationary process §7. Probabilities of large deviations of trajectories of Gaussian fields 7.1. Homogeneous fields and fields with constant dispersion 7.2. Finitely many maximum points of dispersion 7.3. Manifold of maximum points of dispersion 7.4. Asymptotics of distributions of maxima of Wiener fields §8. Exact asymptotics of large deviations of the norm of Gaussian vectors and processes with values in the spaces L_k^p and l^2. Gaussian fields with the set of parameters in Hilbert space 8.1 Exact asymptotics of the distribution of the l_k^p-norm of a Gaussian finite-dimensional vector with dependent coordinates, p > 1 8.2. Exact asymptotics of probabilities of high excursions of trajectories of processes of type \\chi^2 8.3. Asymptotics of the probabilities of large deviations of Gaussian processes with a set of parameters in Hilbert space [74] 8.4. Asymptotics of distributions of maxima of the norms of l^2-valued Gaussian processes 8.5. Exact asymptotics of large deviations for the l^2-valued Ornstein-Uhlenbeck process Bibliography
NASA Astrophysics Data System (ADS)
Stooksbury, David E.; Idso, Craig D.; Hubbard, Kenneth G.
1999-05-01
Gaps in otherwise regularly scheduled observations are often referred to as missing data. This paper explores the spatial and temporal impacts that data gaps in the recorded daily maximum and minimum temperatures have on the calculated monthly mean maximum and minimum temperatures. For this analysis 138 climate stations from the United States Historical Climatology Network Daily Temperature and Precipitation Data set were selected. The selected stations had no missing maximum or minimum temperature values during the period 1951-80. The monthly mean maximum and minimum temperatures were calculated for each station for each month. For each month 1-10 consecutive days of data from each station were randomly removed. This was performed 30 times for each simulated gap period. The spatial and temporal impact of the 1-10-day data gaps were compared. The influence of data gaps is most pronounced in the continental regions during the winter and least pronounced in the southeast during the summer. In the north central plains, 10-day data gaps during January produce a standard deviation value greater than 2°C about the `true' mean. In the southeast, 10-day data gaps in July produce a standard deviation value less than 0.5°C about the mean. The results of this study will be of value in climate variability and climate trend research as well as climate assessment and impact studies.
Dispersion y dinamica poblacional
USDA-ARS?s Scientific Manuscript database
Dispersal behavior of fruit flies is appetitive. Measures of dispersion involve two different parameter: the maximum distance and the standard distance. Standard distance is a parameter that describes the probalility of dispersion and is mathematically equivalent to the standard deviation around ...
2008-06-12
15 14 15 STANDARD DEVIATION (:1:) 3 5 4 4 4 MINIMUM VALUE 9 12 11 8 10 MAXIMUM VALUE 20 33 23 29 24 N" 56 19 14 38 28 IMm ~ ~ CORN Oil l:W...AVERAGE 9 9 10 8 9 STANDARD DEVIATION (:1:) 3 3 4 2 3 MINIMUM VAlUE 2 6 3 5 4 MAXIMUM VAlUE 20 16 23 12 15 N" 65 21 14 33 29 E.COLI DMSO ~ CORN ...21 33 25 21 23 N* 66 19 14 38 28 :wm ~ ACET CORN Oil !L!! SAUNE AVERAGE 9 10 10 9 8 STANDARD DEVlA.11ON (:I:) 3 3 4 3 2 MINIMUM VAWS . 4 6 6 6 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
He Yongzhou; Zhang Jidong; Zhou Qiaogen
Two in-vacuum undulators IVU25s and one elliptically polarized undulator EPU100 have been developed for SSRF. Two IVU25s with the same hybrid design contain about 640 Sm{sub 2}Co{sub 17} magnet blocks and the dimension of blocks is 65 Wx25 Hx9 D. The EPU100 of the APPLE-II type contains about 690 NdFeB magnet blocks with the dimension of 35 Wx35 Hx25 D. This paper describes the magnetic measurements of these magnet blocks with the Helmholtz coil measurement system for IVU25 magnet blocks and the Hall probe measurement system for EPU100 magnet blocks. The measured maximum magnetic moment deviation and the maximum anglemore » deviation are less than {+-}1.0% and 1.1 deg. respectively both for Sm{sub 2}Co{sub 17} blocks and NdFeB blocks and satisfy the specifications of undulators.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Million, Lynn, E-mail: lynn.million@hci.utah.ed; Anderson, James; Breneman, John
2011-06-01
Purpose: Postoperative radiation therapy (RT) is recommended for patients with rhabdomyosarcoma having microscopic disease. Sometimes RT dose/volume is reduced or omitted in an attempt to avoid late effects, particularly in young children. We reviewed operative bed recurrences to determine if noncompliance with RT protocol guidelines influenced local-regional control. Methods and Materials: All operative bed recurrences among 695 Group II rhabdomyosarcoma patients in Intergroup Rhabdomyosarcoma Study Group (IRS) I through IV were reviewed for deviation from RT protocol. Major/minor dose deviation was defined as >10% or 6-10% of the prescribed dose (40-60 Gy), respectively. Major/minor volume deviation was defined as tumormore » excluded from the RT field or treatment volume not covered by the specified margin (preoperative tumor volume and 2- to 5-cm margin), respectively. No RT was a major deviation. Results: Forty-six of 83 (55%) patients with operative bed recurrences did not receive the intended RT (39 major and 7 minor deviations). RT omission was the most frequent RT protocol deviation (19/46, 41%), followed by dose (17/46, 37%), volume (9/46, 20%), and dose and volume deviation (1/46, 2%). Only 7 operative bed recurrences occurred in IRS IV (5% local-regional failure) with only 3 RT protocol deviations. Sixty-three (76%) patients with recurrence died of disease despite retrieval therapy, including 13 of 19 nonirradiated children. Conclusion: Over half of the operative bed recurrences were associated with noncompliance; omission of RT was the most common protocol deviation. Three fourths of children die when local-regional disease is not controlled, emphasizing the importance of RT in Group II rhabdomyosarcoma.« less
Children's Evaluations of Resource Allocation in the Context of Group Norms
ERIC Educational Resources Information Center
Cooley, Shelby; Killen, Melanie
2015-01-01
This study investigated children's evaluations of peer group members who deviated from group norms about equal and unequal allocation of resources. Children, ages 3.5 to 4 years and 5 to 6 years (N = 73), were asked to evaluate a peer group member who deviated from 1 of 2 group allocation norms: (a) equal allocation of resources, or (b) unequal…
Sefi-Yurdakul, Nazife; Kaykısız, Hüseyin; Koç, Feray
2018-03-17
To investigate the effects of partial and full correction of refractive errors on sensorial and motor outcomes in children with refractive accommodative esotropia (RAE). The records of pediatric cases with full RAE were reviewed; their first and last sensorial and motor findings were evaluated in two groups, classified as partial (Group 1) and full correction (Group 2) of refractive errors. The mean age at first admission was 5.84 ± 3.62 years in Group 1 (n = 35) and 6.35 ± 3.26 years in Group 2 (n = 46) (p = 0.335). Mean change in best corrected visual acuity (BCVA) was 0.24 ± 0.17 logarithm of the minimum angle of resolution (logMAR) in Group 1 and 0.13 ± 0.16 logMAR in Group 2 (p = 0.001). Duration of deviation, baseline refraction and amount of reduced refraction showed significant effects on change in BCVA (p < 0.05). Significant correlation was determined between binocular vision (BOV), duration of deviation and uncorrected baseline amount of deviation (p < 0.05). The baseline BOV rates were significantly high in fully corrected Group 2, and also were found to have increased in Group 1 (p < 0.05). Change in refraction was - 0.09 ± 1.08 and + 0.35 ± 0.76 diopters in Groups 1 and 2, respectively (p = 0.005). Duration of deviation, baseline refraction and the amount of reduced refraction had significant effects on change in refraction (p < 0.05). Change in deviation without refractive correction was - 0.74 ± 7.22 prism diopters in Group 1 and - 3.24 ± 10.41 prism diopters in Group 2 (p = 0.472). Duration of follow-up and uncorrected baseline deviation showed significant effects on change in deviation (p < 0.05). Although the BOV rates and BCVA were initially high in fully corrected patients, they finally improved significantly in both the fully and partially corrected patients. Full hypermetropic correction may also cause an increase in the refractive error with a possible negative effect on emmetropization. The negative effect of the duration of deviation on BOV and BCVA demonstrates the significance of early treatment in RAE cases.
Du, Bing-Li; Li, Jiang-Ning; Guo, Hong-Ming; Li, Song; Liu, Biao
2017-09-01
The aim of this study is to explore the effects of abnormal occlusion and functional recovery caused by functional mandible deviation on the head and neck muscles and muscle spindle sensory-motor system by electrophysiological response and endogenous monoamine neurotransmitters' distribution in the nucleus of the spinal tract. Seven-week-old male Wistar rats were randomly divided into 7 groups: normal control group, 2W experimental control group, 2W functional mandible deviation group, 2W functional mandible deviation recovery group, 4W experimental control group, 4W functional mandible deviation group, 4W functional mandible deviation recovery group. Chewing muscles, digastric muscle, splenius, and trapezius muscle spindles electrophysiological response activities at the opening and closing state were recorded. And then the chewing muscles, digastric, splenius, trapezius, and neck trigeminal nucleus were taken for histidine decarboxylase (HDC) detection by high performance liquid chromatography (HPLC), immunofluorescence, and reverse-transcription polymerase chain reaction (RT-PCR). Histamine receptor proteins in the neck nucleus of the spinal tract were also examined by immunofluorescence and RT-PCR. Electromyography activity of chewing muscles, digastric, and splenius muscle was significantly asymmetric; the abnormal muscle electromyography activity was mainly detected at the ipsilateral side. After functional mandibular deviation, muscle sensitivity on the ipsilateral sides of the chewing muscle and splenius decreased, muscle excitement weakened, modulation depth decreased, and the muscle spindle afferent impulses of excitation transmission speed slowed down. Changes for digastric muscle electrical activity were contrary. The functions recovered at different extents after removing the deflector. However, trapezius in all the experimental groups and recovery groups exhibited bilateral symmetry electrophysiological responses, and no significant difference compared with the control group. After functional mandibular deviation, HDC protein and messenger ribonucleic acid (mRNA) levels on the ipsilateral sides of the chewing muscle and splenius increased significantly. HDC level changes for digastric muscle were contrary. After the removal of the mandibular position deflector, HDC protein and mRNA levels decreased on the ipsilateral sides of the chewing muscle and splenius while they increased in the digastric muscle. The difference of histamine decarboxylase content in the bilateral trapezius in each experimental group was small. After functional mandibular deviation, the temporomandibular joint mechanical receptors not only caused the fusimotor fiber hypoallergenic fatigue slow response on the ipsilateral sides of splenius, but also increased the injury neurotransmitter histamine release. The authors' results further support the opinion that the temporomandibular joint receptors may be involved in the mechanical theory of the head and neck muscles nervous system regulation.
Accuracy of maximum likelihood estimates of a two-state model in single-molecule FRET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gopich, Irina V.
2015-01-21
Photon sequences from single-molecule Förster resonance energy transfer (FRET) experiments can be analyzed using a maximum likelihood method. Parameters of the underlying kinetic model (FRET efficiencies of the states and transition rates between conformational states) are obtained by maximizing the appropriate likelihood function. In addition, the errors (uncertainties) of the extracted parameters can be obtained from the curvature of the likelihood function at the maximum. We study the standard deviations of the parameters of a two-state model obtained from photon sequences with recorded colors and arrival times. The standard deviations can be obtained analytically in a special case when themore » FRET efficiencies of the states are 0 and 1 and in the limiting cases of fast and slow conformational dynamics. These results are compared with the results of numerical simulations. The accuracy and, therefore, the ability to predict model parameters depend on how fast the transition rates are compared to the photon count rate. In the limit of slow transitions, the key parameters that determine the accuracy are the number of transitions between the states and the number of independent photon sequences. In the fast transition limit, the accuracy is determined by the small fraction of photons that are correlated with their neighbors. The relative standard deviation of the relaxation rate has a “chevron” shape as a function of the transition rate in the log-log scale. The location of the minimum of this function dramatically depends on how well the FRET efficiencies of the states are separated.« less
Accuracy of maximum likelihood estimates of a two-state model in single-molecule FRET
Gopich, Irina V.
2015-01-01
Photon sequences from single-molecule Förster resonance energy transfer (FRET) experiments can be analyzed using a maximum likelihood method. Parameters of the underlying kinetic model (FRET efficiencies of the states and transition rates between conformational states) are obtained by maximizing the appropriate likelihood function. In addition, the errors (uncertainties) of the extracted parameters can be obtained from the curvature of the likelihood function at the maximum. We study the standard deviations of the parameters of a two-state model obtained from photon sequences with recorded colors and arrival times. The standard deviations can be obtained analytically in a special case when the FRET efficiencies of the states are 0 and 1 and in the limiting cases of fast and slow conformational dynamics. These results are compared with the results of numerical simulations. The accuracy and, therefore, the ability to predict model parameters depend on how fast the transition rates are compared to the photon count rate. In the limit of slow transitions, the key parameters that determine the accuracy are the number of transitions between the states and the number of independent photon sequences. In the fast transition limit, the accuracy is determined by the small fraction of photons that are correlated with their neighbors. The relative standard deviation of the relaxation rate has a “chevron” shape as a function of the transition rate in the log-log scale. The location of the minimum of this function dramatically depends on how well the FRET efficiencies of the states are separated. PMID:25612692
Gauging Skills of Hospital Security Personnel: a Statistically-driven, Questionnaire-based Approach.
Rinkoo, Arvind Vashishta; Mishra, Shubhra; Rahesuddin; Nabi, Tauqeer; Chandra, Vidha; Chandra, Hem
2013-01-01
This study aims to gauge the technical and soft skills of the hospital security personnel so as to enable prioritization of their training needs. A cross sectional questionnaire based study was conducted in December 2011. Two separate predesigned and pretested questionnaires were used for gauging soft skills and technical skills of the security personnel. Extensive statistical analysis, including Multivariate Analysis (Pillai-Bartlett trace along with Multi-factorial ANOVA) and Post-hoc Tests (Bonferroni Test) was applied. The 143 participants performed better on the soft skills front with an average score of 6.43 and standard deviation of 1.40. The average technical skills score was 5.09 with a standard deviation of 1.44. The study avowed a need for formal hands on training with greater emphasis on technical skills. Multivariate analysis of the available data further helped in identifying 20 security personnel who should be prioritized for soft skills training and a group of 36 security personnel who should receive maximum attention during technical skills training. This statistically driven approach can be used as a prototype by healthcare delivery institutions worldwide, after situation specific customizations, to identify the training needs of any category of healthcare staff.
Clemente-Suárez, Vicente Javier; Arroyo-Toledo, Juan Jaime
2018-01-25
The aim of the present research was to analyze the autonomic response in a group of trained swimmers before and after conducting a 4-week period of high-intensity interval training (HIT). Heart rate variability was analyzed in 14 swimmers (16.2 ± 2.6 years, 169.1 ± 10.2 cm and 61.3 ± 9.9 kg) in basal condition and during a HIT session before and after completing a training period. The HIT session that was evaluated consisted of: 16 × 25 m maximum speed, resting 30 s between sets. Participants combined aerobic training with tethered swimming and HIT sessions three times per week in a period of 4 weeks. Results showed a significantly decrease (p < 0.05) of the standard deviation of the NN intervals (SDNN), the standard deviation of differences between adjacent NN intervals (SDSD), the number of successive difference of intervals which differ by more than 50 ms (NN50), after the training period. Results showed a higher parasympathetic activation besides improvements in autonomic adaptation after HIT training period.
Gauging Skills of Hospital Security Personnel: a Statistically-driven, Questionnaire-based Approach
Rinkoo, Arvind Vashishta; Mishra, Shubhra; Rahesuddin; Nabi, Tauqeer; Chandra, Vidha; Chandra, Hem
2013-01-01
Objectives This study aims to gauge the technical and soft skills of the hospital security personnel so as to enable prioritization of their training needs. Methodology A cross sectional questionnaire based study was conducted in December 2011. Two separate predesigned and pretested questionnaires were used for gauging soft skills and technical skills of the security personnel. Extensive statistical analysis, including Multivariate Analysis (Pillai-Bartlett trace along with Multi-factorial ANOVA) and Post-hoc Tests (Bonferroni Test) was applied. Results The 143 participants performed better on the soft skills front with an average score of 6.43 and standard deviation of 1.40. The average technical skills score was 5.09 with a standard deviation of 1.44. The study avowed a need for formal hands on training with greater emphasis on technical skills. Multivariate analysis of the available data further helped in identifying 20 security personnel who should be prioritized for soft skills training and a group of 36 security personnel who should receive maximum attention during technical skills training. Conclusion This statistically driven approach can be used as a prototype by healthcare delivery institutions worldwide, after situation specific customizations, to identify the training needs of any category of healthcare staff. PMID:23559904
An efficient approach for improving virtual machine placement in cloud computing environment
NASA Astrophysics Data System (ADS)
Ghobaei-Arani, Mostafa; Shamsi, Mahboubeh; Rahmanian, Ali A.
2017-11-01
The ever increasing demand for the cloud services requires more data centres. The power consumption in the data centres is a challenging problem for cloud computing, which has not been considered properly by the data centre developer companies. Especially, large data centres struggle with the power cost and the Greenhouse gases production. Hence, employing the power efficient mechanisms are necessary to optimise the mentioned effects. Moreover, virtual machine (VM) placement can be used as an effective method to reduce the power consumption in data centres. In this paper by grouping both virtual and physical machines, and taking into account the maximum absolute deviation during the VM placement, the power consumption as well as the service level agreement (SLA) deviation in data centres are reduced. To this end, the best-fit decreasing algorithm is utilised in the simulation to reduce the power consumption by about 5% compared to the modified best-fit decreasing algorithm, and at the same time, the SLA violation is improved by 6%. Finally, the learning automata are used to a trade-off between power consumption reduction from one side, and SLA violation percentage from the other side.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Hyewon; Hwang, Min; Muljadi, Eduard
In an electric power grid that has a high penetration level of wind, the power fluctuation of a large-scale wind power plant (WPP) caused by varying wind speeds deteriorates the system frequency regulation. This paper proposes a power-smoothing scheme of a doubly-fed induction generator (DFIG) that significantly mitigates the system frequency fluctuation while preventing over-deceleration of the rotor speed. The proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while preventing over-deceleration of the rotor speed, the gain ofmore » the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. In conclusion, the simulation results based on the IEEE 14-bus system clearly demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WPP under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.« less
Lee, Hyewon; Hwang, Min; Muljadi, Eduard; ...
2017-04-18
In an electric power grid that has a high penetration level of wind, the power fluctuation of a large-scale wind power plant (WPP) caused by varying wind speeds deteriorates the system frequency regulation. This paper proposes a power-smoothing scheme of a doubly-fed induction generator (DFIG) that significantly mitigates the system frequency fluctuation while preventing over-deceleration of the rotor speed. The proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while preventing over-deceleration of the rotor speed, the gain ofmore » the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. In conclusion, the simulation results based on the IEEE 14-bus system clearly demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WPP under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.« less
NASA Technical Reports Server (NTRS)
Barnhart, Paul J.; Greber, Isaac
1997-01-01
A series of experiments were performed to investigate the effects of Mach number variation on the characteristics of the unsteady shock wave/turbulent boundary layer interaction generated by a blunt fin. A single blunt fin hemicylindrical leading edge diameter size was used in all of the experiments which covered the Mach number range from 2.0 to 5.0. The measurements in this investigation included surface flow visualization, static and dynamic pressure measurements, both on centerline and off-centerline of the blunt fin axis. Surface flow visualization and static pressure measurements showed that the spatial extent of the shock wave/turbulent boundary layer interaction increased with increasing Mach number. The maximum static pressure, normalized by the incoming static pressure, measured at the peak location in the separated flow region ahead of the blunt fin was found to increase with increasing Mach number. The mean and standard deviations of the fluctuating pressure signals from the dynamic pressure transducers were found to collapse to self-similar distributions as a function of the distance perpendicular to the separation line. The standard deviation of the pressure signals showed initial peaked distribution, with the maximum standard deviation point corresponding to the location of the separation line at Mach number 3.0 to 5.0. At Mach 2.0 the maximum standard deviation point was found to occur significantly upstream of the separation line. The intermittency distributions of the separation shock wave motion were found to be self-similar profiles for all Mach numbers. The intermittent region length was found to increase with Mach number and decrease with interaction sweepback angle. For Mach numbers 3.0 to 5.0 the separation line was found to correspond to high intermittencies or equivalently to the downstream locus of the separation shock wave motion. The Mach 2.0 tests, however, showed that the intermittent region occurs significantly upstream of the separation line. Power spectral densities measured in the intermittent regions were found to have self-similar frequency distributions when compared as functions of a Strouhal number for all Mach numbers and interaction sweepback angles. The maximum zero-crossing frequencies were found to correspond with the peak frequencies in the power spectra measured in the intermittent region.
Relative air temperature analysis external building on Gowa Campus
NASA Astrophysics Data System (ADS)
Mustamin, Tayeb; Rahim, Ramli; Baharuddin; Jamala, Nurul; Kusno, Asniawaty
2018-03-01
This study aims to data analyze the relative temperature and humidity of the air outside the building. Data retrieval taken from weather monitoring device (monitoring) Vaisala, RTU (Remote Terminal Unit), Which is part of the AWS (Automatic Weather Stations) Then Processing data processed and analyzed by using Microsoft Excel program in the form of graph / picture fluctuation Which shows the average value, standard deviation, maximum value, and minimum value. Results of data processing then grouped in the form: Daily, and monthly, based on time intervals every 30 minutes. The results showed Outside air temperatures in March, April, May and September 2016 Which entered in the thermal comfort zone according to SNI standard (Indonesian National Standard) only at 06.00-10.00. In late March to early April Thermal comfort zone also occurs at 15.30-18.00. The highest maximum air temperature occurred in September 2016 at 11.01-11.30 And the lowest minimum value in September 2016, time 6:00 to 6:30. The result of the next analysis shows the level of data conformity with thermal comfort zone based on SNI (Indonesian National Standard) every month.
Dimensional analyses of frontal posed smile attractiveness in Japanese female patients.
Hata, Kyoko; Arai, Kazuhito
2016-01-01
To identify appropriate dimensional items in objective diagnostic analysis for attractiveness of frontal posed smile in Japanese female patients by comparing with the result of human judgments. Photographs of frontal posed smiles of 100 Japanese females after orthodontic treatment were evaluated by 20 dental students (10 males and 10 females) using a visual analogue scale (VAS). The photographs were ranked based on the VAS evaluations and the 25 photographs with the highest evaluations were selected as group A, and the 25 photos with the lowest evaluations were designated group B. Then 12 dimensional items of objective analysis selected from a literature review were measured. Means and standard deviations for measurements of the dimensional items were compared between the groups using the unpaired t-test with a significance level of P < .05. Mean values were significantly smaller in group A than in group B for interlabial gap, intervermilion distance, maxillary gingival display, maximum incisor exposure, and lower lip to incisor (P < .05). Significant differences were observed only in the vertical dimension, not in the transverse dimension. Five of the 12 objective diagnostic items were correlated with human judgments of the attractiveness of frontal posed smile in Japanese females after orthodontic treatment.
A Correlational Study of Scoliosis and Trunk Balance in Adult Patients with Mandibular Deviation
Yang, Yang; Wang, Na; Wang, Wenyong; Ding, Yin; Sun, Shiyao
2013-01-01
Previous studies have confirmed that patients with mandibular deviation often have abnormal morphology of their cervical vertebrae. However, the relationship between mandibular deviation, scoliosis, and trunk balance has not been studied. Currently, mandibular deviation is usually treated as a single pathology, which leads to poor clinical efficiency. We investigated the relationship of spine coronal morphology and trunk balance in adult patients with mandibular deviation, and compared the finding to those in healthy volunteers. 35 adult patients with skeletal mandibular deviation and 10 healthy volunteers underwent anterior X-ray films of the head and posteroanterior X-ray films of the spine. Landmarks and lines were drawn and measured on these films. The axis distance method was used to measure the degree of scoliosis and the balance angle method was used to measure trunk balance. The relationship of mandibular deviation, spine coronal morphology and trunk balance was evaluated with the Pearson correlation method. The spine coronal morphology of patients with mandibular deviation demonstrated an “S” type curve, while a straight line parallel with the gravity line was found in the control group (significant difference, p<0.01). The trunk balance of patients with mandibular deviation was disturbed (imbalance angle >1°), while the control group had a normal trunk balance (imbalance angle <1°). There was a significant difference between the two groups (p<0.01). The degree of scoliosis and shoulder imbalance correlated with the degree of mandibular deviation, and presented a linear trend. The direction of mandibular deviation was the same as that of the lateral bending of thoracolumbar vertebrae, which was opposite to the direction of lateral bending of cervical vertebrae. Our study shows the degree of mandibular deviation has a high correlation with the degree of scoliosis and trunk imbalance, all the three deformities should be clinically evaluated in the management of mandibular deviation. PMID:23555836
Multichannel infrared fiber optic radiometer for controlled microwave heating
NASA Astrophysics Data System (ADS)
Drizlikh, S.; Zur, Albert; Katzir, Abraham
1990-07-01
An infrared fiberoptic multichannel radiometer was used for monitoring and controlling the temperature of samples in a microwave heating system. The temperature of water samples was maintained at about 40 °C, with a standard deviation of +/- 0.2°C and a maximum deviation of +/- 0.5°C. The temperature was monitored on the same time at several points on the surface and inside the sample. This novel controlled system is reliable and precise. Such system would be very useful for medical applications such as hypothermia and hyperthermi a.
Lin, Yifan; Chen, Gui; Fu, Zhen; Ma, Lian; Li, Weiran
2015-01-01
To evaluate, using cone-beam computed tomography (CBCT), both the condylar-fossa relationships and the mandibular and condylar asymmetries between unilateral cleft lip and palate (UCLP) patients and non-cleft patients with class III skeletal relationship, and to investigate the factors of asymmetry contributing to chin deviation. The UCLP and non-cleft groups consisted of 30 and 40 subjects, respectively, in mixed dentition with class III skeletal relationships. Condylar-fossa relationships and the dimensional and positional asymmetries of the condyles and mandibles were examined using CBCT. Intra-group differences were compared between two sides in both groups using a paired t-test. Furthermore, correlations between each measurement and chin deviation were assessed. It was observed that 90% of UCLP and 67.5% of non-cleft subjects had both condyles centered, and no significant asymmetry was found. The axial angle and the condylar center distances to the midsagittal plane were significantly greater on the cleft side than on the non-cleft side (P=0.001 and P=0.028, respectively) and were positively correlated with chin deviation in the UCLP group. Except for a larger gonial angle on the cleft side, the two groups presented with consistent asymmetries showing shorter mandibular bodies and total mandibular lengths on the cleft (deviated) side. The average chin deviation was 1.63 mm to the cleft side, and the average absolute chin deviation was significantly greater in the UCLP group than in the non-cleft group (P=0.037). Compared with non-cleft subjects with similar class III skeletal relationships, the subjects with UCLP showed more severe lower facial asymmetry. The subjects with UCLP presented with more asymmetrical positions and rotations of the condyles on axial slices, which were positively correlated with chin deviation.
Influence of occlusal plane inclination and mandibular deviation on esthetics
Corte, Cristiane Cherobini Dalla; da Silveira, Bruno Lopes; Marquezan, Mariana
2015-01-01
Objective: The aim of this study was to assess the degree of perception of occlusal plane inclination and mandibular deviation in facial esthetics, assessed by laypeople, dentists and orthodontists. Methods: A woman with 5.88° of inclination and 5.54 mm of mandibular deviation was selected and, based on her original photograph, four new images were created correcting the deviations and creating more symmetric faces and smiles. Examiners assessed the images by means of a questionnaire. Their opinions were compared by qualitative and quantitative analyses. Results: A total of 45 laypeople, 27 dentists and 31 orthodontists filled out the questionnaires. All groups were able to perceive the asymmetry; however, orthodontists were more sensitive, identifying asymmetries as from 4.32° of occlusal plane inclination and 4.155 mm of mandibular deviation (p< 0.05). The other categories of evaluators identified asymmetries and assigned significantly lower grades, starting from 5.88° of occlusal plane inclination and 5.54 mm of mandibular deviation (p< 0.05). Conclusion: Occlusal plane inclination and mandibular deviation were perceived by all groups, but orthodontists presented higher perception of deviations. PMID:26560821
Borcherdt, Roger D.; Wennerberg, Leif
1985-01-01
The physical characteristics for general plane-wave radiation fields in an arbitrary linear viscoelastic solid are derived. Expressions for the characteristics of inhomogeneous wave fields, derived in terms of those for homogeneous fields, are utilized to specify the characteristics and a set of reference curves for general P and S wave fields in arbitrary viscoelastic solids as a function of wave inhomogeneity and intrinsic material absorption. The expressions show that an increase in inhomogeneity of the wave fields cause the velocity to decrease, the fractional-energy loss (Q** minus **1) to increase, the deviation of maximum energy flow with respect to phase propagation to increase, and the elliptical particle motions for P and type-I S waves to approach circularity. Q** minus **1 for inhomogeneous type-I S waves is shown to be greater than that for type-II S waves, with the deviation first increasing then decreasing with inhomogeneity. The mean energy densities (kinetic, potential, and total), the mean rate of energy dissipation, the mean energy flux, and Q** minus **1 for inhomogeneous waves are shown to be greater than corresponding characteristics for homogeneous waves, with the deviations increasing as the inhomogeneity is increased for waves of fixed maximum displacement amplitude.
Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline
2014-06-01
What is the mean Berg Balance Scale score of healthy elderly people living in the community and how does it vary with age? How much variability in Berg Balance Scale scores is present in groups of healthy elderly people and how does this vary with age? Systematic review with meta-analysis. Any group of healthy community-dwelling people with a mean age of 70 years or greater that has undergone assessment using the Berg Balance Scale. Mean and standard deviations of Berg Balance Scale scores within cohorts of elderly people of known mean age. The search yielded 17 relevant studies contributing data from a total of 1363 participants. The mean Berg Balance Scale scores ranged from 37 to 55 out of a possible maximum score of 56. The standard deviation of Berg Balance Scale scores varied from 1.0 to 9.2. Although participants aged around 70 years had very close to normal Berg Balance Scale scores, there was a significant decline in balance with age at a rate of 0.7 points on the 56-point Berg Balance Scale per year. There was also a strong association between increasing age and increasing variability in balance (R(2) = 0.56, p < 0.001). Healthy community-dwelling elderly people have modest balance deficits, as measured by the Berg Balance Scale, although balance scores deteriorate and become more variable with age. Copyright © 2014. Published by Elsevier B.V.
Anti-inflammatory drugs and prediction of new structures by comparative analysis.
Bartzatt, Ronald
2012-01-01
Nonsteroidal anti-inflammatory drugs (NSAIDs) are a group of agents important for their analgesic, anti-inflammatory, and antipyretic properties. This study presents several approaches to predict and elucidate new molecular structures of NSAIDs based on 36 known and proven anti-inflammatory compounds. Based on 36 known NSAIDs the mean value of Log P is found to be 3.338 (standard deviation= 1.237), mean value of polar surface area is 63.176 Angstroms2 (standard deviation = 20.951 A2), and the mean value of molecular weight is 292.665 (standard deviation = 55.627). Nine molecular properties are determined for these 36 NSAID agents, including Log P, number of -OH and -NHn, violations of Rule of 5, number of rotatable bonds, and number of oxygens and nitrogens. Statistical analysis of these nine molecular properties provides numerical parameters to conform to in the design of novel NSAID drug candidates. Multiple regression analysis is accomplished using these properties of 36 agents followed with examples of predicted molecular weight based on minimum and maximum property values. Hierarchical cluster analysis indicated that licofelone, tolfenamic acid, meclofenamic acid, droxicam, and aspirin are substantially distinct from all remaining NSAIDs. Analysis of similarity (ANOSIM) produced R = 0.4947, which indicates low to moderate level of dissimilarity between these 36 NSAIDs. Non-hierarchical K-means cluster analysis separated the 36 NSAIDs into four groups having members of greatest similarity. Likewise, discriminant analysis divided the 36 agents into two groups indicating the greatest level of distinction (discrimination) based on nine properties. These two multivariate methods together provide investigators a means to compare and elucidate novel drug designs to 36 proven compounds and ascertain to which of those are most analogous in pharmacodynamics. In addition, artificial neural network modeling is demonstrated as an approach to predict numerous molecular properties of new drug designs that is based on neural training from 36 proven NSAIDs. Comprehensive and effective approaches are presented in this study for the design of new NSAID type agents which are so very important for inhibition of COX-2 and COX-1 isoenzymes.
Arisan, Volkan; Karabuda, Zihni Cüneyt; Pişkin, Bülent; Özdemir, Tayfun
2013-12-01
Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study. Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides. A new CT or CBCT scan was obtained and merged with the planning data to identify the deviations between the planned and placed implants. Results were analyzed by Mann-Whitney U test and multiple regressions (p < .05). Mean angular and linear deviations in the CT group were 3.30° (SD 0.36), and 0.75 (SD 0.32) and 0.80 mm (SD 0.35) at the implant shoulder and tip, respectively. In the CBCT group, mean angular and linear deviations were 3.47° (SD 0.37), and 0.81 (SD 0.32) and 0.87 mm (SD 0.32) at the implant shoulder and tip, respectively. No statistically significant differences were detected between the CT and CBCT groups (p = .169 and p = .551, p = .113 for angular and linear deviations, respectively). Implant placement via CT- or CBCT-derived mucosa-supported SLA guides yielded similar deviation values. Results should be confirmed on alternative CBCT scanners. © 2012 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Warger, William C., II; Newmark, Judith A.; Zhao, Bing; Warner, Carol M.; DiMarzio, Charles A.
2006-02-01
Present imaging techniques used in in vitro fertilization (IVF) clinics are unable to produce accurate cell counts in developing embryos past the eight-cell stage. We have developed a method that has produced accurate cell counts in live mouse embryos ranging from 13-25 cells by combining Differential Interference Contrast (DIC) and Optical Quadrature Microscopy. Optical Quadrature Microscopy is an interferometric imaging modality that measures the amplitude and phase of the signal beam that travels through the embryo. The phase is transformed into an image of optical path length difference, which is used to determine the maximum optical path length deviation of a single cell. DIC microscopy gives distinct cell boundaries for cells within the focal plane when other cells do not lie in the path to the objective. Fitting an ellipse to the boundary of a single cell in the DIC image and combining it with the maximum optical path length deviation of a single cell creates an ellipsoidal model cell of optical path length deviation. Subtracting the model cell from the Optical Quadrature image will either show the optical path length deviation of the culture medium or reveal another cell underneath. Once all the boundaries are used in the DIC image, the subtracted Optical Quadrature image is analyzed to determine the cell boundaries of the remaining cells. The final cell count is produced when no more cells can be subtracted. We have produced exact cell counts on 5 samples, which have been validated by Epi-Fluorescence images of Hoechst stained nuclei.
Dåderman, Anna M; Hellström, Ake; Wennberg, Peter; Törestad, Bertil
2005-01-01
The aim of the present study was to investigate relationships between scales from the Karolinska Scales of Personality (KSP) and the factor structure of the KSP in a sample of male juvenile delinquents. The KSP was administered to a group of male juvenile delinquents (n=55, mean age 17 years; standard deviation=1.2) from four Swedish national correctional institutions for serious offenders. As expected, the KSP showed appropriate correlations between the scales. Factor analysis (maximum likelihood) arrived at a four-factor solution in this sample, which is in line with previous research performed in a non-clinical sample of Swedish males. More research is needed in a somewhat larger sample of juvenile delinquents in order to confirm the present results regarding the factor solution.
Gait analysis in children with cerebral palsy.
Armand, Stéphane; Decoulon, Geraldo; Bonnefoy-Mazure, Alice
2016-12-01
Cerebral palsy (CP) children present complex and heterogeneous motor disorders that cause gait deviations.Clinical gait analysis (CGA) is needed to identify, understand and support the management of gait deviations in CP. CGA assesses a large amount of quantitative data concerning patients' gait characteristics, such as video, kinematics, kinetics, electromyography and plantar pressure data.Common gait deviations in CP can be grouped into the gait patterns of spastic hemiplegia (drop foot, equinus with different knee positions) and spastic diplegia (true equinus, jump, apparent equinus and crouch) to facilitate communication. However, gait deviations in CP tend to be a continuum of deviations rather than well delineated groups. To interpret CGA, it is necessary to link gait deviations to clinical impairments and to distinguish primary gait deviations from compensatory strategies.CGA does not tell us how to treat a CP patient, but can provide objective identification of gait deviations and further the understanding of gait deviations. Numerous treatment options are available to manage gait deviations in CP. Generally, treatments strive to limit secondary deformations, re-establish the lever arm function and preserve muscle strength.Additional roles of CGA are to better understand the effects of treatments on gait deviations. Cite this article: Armand S, Decoulon G, Bonnefoy-Mazure A. Gait analysis in children with cerebral palsy. EFORT Open Rev 2016;1:448-460. DOI: 10.1302/2058-5241.1.000052.
New CFD tools to evaluate nasal airflow.
Burgos, M A; Sanmiguel-Rojas, E; Del Pino, C; Sevilla-García, M A; Esteban-Ortega, F
2017-08-01
Computational fluid dynamics (CFD) is a mathematical tool to analyse airflow. As currently CFD is not a usual tool for rhinologists, a group of engineers in collaboration with experts in Rhinology have developed a very intuitive CFD software. The program MECOMLAND ® only required snapshots from the patient's cross-sectional (tomographic) images, being the output those results originated by CFD, such as airflow distributions, velocity profiles, pressure, temperature, or wall shear stress. This is useful complementary information to cover diagnosis, prognosis, or follow-up of nasal pathologies based on quantitative magnitudes linked to airflow. In addition, the user-friendly environment NOSELAND ® helps the medical assessment significantly in the post-processing phase with dynamic reports using a 3D endoscopic view. Specialists in Rhinology have been asked for a more intuitive, simple, powerful CFD software to offer more quality and precision in their work to evaluate the nasal airflow. We present MECOMLAND ® and NOSELAND ® which have all the expected characteristics to fulfil this demand and offer a proper assessment with the maximum of quality plus safety for the patient. These programs represent a non-invasive, low-cost (as the CT scan is already performed in every patient) alternative for the functional study of the difficult rhinologic case. To validate the software, we studied two groups of patients from the Ear Nose Throat clinic, a first group with normal noses and a second group presenting septal deviations. Wall shear stresses are lower in the cases of normal noses in comparison with those for septal deviation. Besides, velocity field distributions, pressure drop between nasopharynx and the ambient, and flow rates in each nostril were different among the nasal cavities in the two groups. These software modules open up a promising future to simulate the nasal airflow behaviour in virtual surgery intervention scenarios under different pressure or temperature conditions to understand the effects on nasal airflow.
1980-05-28
Total Deviation Angles and Measured Inlet Axial Velocity . . . . 55 ix LIST OF FIGURES (Continued) Figure Page 19 Points Defining Blade Sections of...distance from leading edge to point of maximum camber along chord line ar tip vortex core radius AVR axial velocity ratio (Vx /V x c chord length CL tip...yaw ceoefficient d longitudinal distance from leading edge to tip vortex calculation point G distance from chord line to maximum camber point K cascade
Ahn, Jaechan; Kim, Sung-Jin; Lee, Ji-Yeon; Chung, Chooryung J; Kim, Kyung-Ho
2017-01-01
The purposes of this study were to compare the buccolingual inclinations of the posterior teeth in skeletal Class III patients with and without facial asymmetry with those of skeletal Class I patients and to investigate their relationships with sagittal and transverse skeletal discrepancies. Sixty-three skeletal Class III adult patients were divided into 2 groups according to the degree of menton deviation: a symmetry group with deviation less than 2 mm (n = 30), and an asymmetry group with deviation greater than 4 mm (n = 33). The control group comprised 25 skeletal Class I patients. The buccolingual inclinations of the posterior teeth measured on cone-beam computed tomography images were compared among the 3 groups, and regression analysis was performed to investigate the relationships between the inclinations and the sagittal and transverse skeletal discrepancies. The symmetry group showed greater buccal inclinations of the maxillary posterior teeth and lingual inclinations of the mandibular second molars than did the control, and this was correlated with the ANB angles. The deviated sides in the asymmetry group showed the greatest transverse dental compensation, which was correlated with menton deviation, whereas the nondeviated sides showed no significant transverse dental compensation. Transverse dental compensation is closely related to sagittal and transverse skeletal discrepancy in skeletal Class III patients. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Mandibular movement range in children.
Machado, Barbara Cristina Zanandréa; Medeiros, Ana Paula Magalhães; Felício, Cláudia Maria de
2009-01-01
identification of the mandibular movement range is an important procedure in the evaluation of the stomatognathic system. However, there are few studies in children that focus on normal parameters or abnormalities. to determine the average range of mandibular movements in Brazilian children aged 6 to 12 years; to verify the difference between genders, in each age group, and between the different age groups: 6-8 years; 8.1-10 years; and 10.1-12 years. participants of the study were 240 healthy children selected among regular students from local schools of São Paulo State. The maximum mandibular opening, lateral excursion and protrusive movements, and deviation of the medium line, if present, were measured using a digital caliper. Student T test, Analysis of variance and Tukey test were considered significant for p < 0.05. the mean values observed in the studied sample were: 44.51mm for maximum mandibular opening; 7.71mm for lateral excursion to the right; 7.92mm for lateral excursion to the left; 7.45mm for protrusive movements. No statistical difference was observed between genders. There was a gradual increase in the range of mandibular movements, with significant differences mainly between the ages of 6-8 years and 10.1-12 years. during childhood the range of mandibular movements increases. Age should be considered in this analysis for a greater precision in the diagnosis.
Giżyńska, Marta K.; Kukołowicz, Paweł F.; Kordowski, Paweł
2014-01-01
Aim The aim of this work is to present a method of beam weight and wedge angle optimization for patients with prostate cancer. Background 3D-CRT is usually realized with forward planning based on a trial and error method. Several authors have published a few methods of beam weight optimization applicable to the 3D-CRT. Still, none on these methods is in common use. Materials and methods Optimization is based on the assumption that the best plan is achieved if dose gradient at ICRU point is equal to zero. Our optimization algorithm requires beam quality index, depth of maximum dose, profiles of wedged fields and maximum dose to femoral heads. The method was tested for 10 patients with prostate cancer, treated with the 3-field technique. Optimized plans were compared with plans prepared by 12 experienced planners. Dose standard deviation in target volume, and minimum and maximum doses were analyzed. Results The quality of plans obtained with the proposed optimization algorithms was comparable to that prepared by experienced planners. Mean difference in target dose standard deviation was 0.1% in favor of the plans prepared by planners for optimization of beam weights and wedge angles. Introducing a correction factor for patient body outline for dose gradient at ICRU point improved dose distribution homogeneity. On average, a 0.1% lower standard deviation was achieved with the optimization algorithm. No significant difference in mean dose–volume histogram for the rectum was observed. Conclusions Optimization shortens very much time planning. The average planning time was 5 min and less than a minute for forward and computer optimization, respectively. PMID:25337411
Residue depletion of tilmicosin in chicken tissues.
Zhang, Yue; Jiang, Haiyang; Jin, Xingjun; Shen, Zhangqi; Shen, Jianzhong; Fu, Caixia; Guo, Junlin
2004-05-05
A high-performance liquid chromatography (HPLC) method with detection at 290 nm was modified and validated for the determination of tilmicosin residues in broiler chicken tissues. The limits of detection (LOD) of the method were 0.01 microg/g for muscle and 0.025 microg/g for liver and kidney. Average recoveries ranged from 80.4 to 88.3%. Relative standard deviation values ranged from 5.2 to 12.1%. Residue depletion of tilmicosin in broiler chickens was examined after dosing over a 5-day period by incorporation of the drug into drinking water at 37.5 and 75.0 mg/L. Tilmicosin concentrations in liver and kidney were highest on day 3 of medication and on day 5 in muscle, in both low- and high-dose groups. The residue levels in both groups were significantly higher in liver than in kidney or muscle. A minimum withdrawal time of 9 days was indicated for residue levels in muscle, liver, and kidney tissues below the maximum residue level (MRL).
Social smile reproducibility using 3-D stereophotogrammetry and reverse engineering technology.
Dindaroğlu, Furkan; Duran, Gökhan Serhat; Görgülü, Serkan; Yetkiner, Enver
2016-05-01
To assess the range of social smile reproducibility using 3-D stereophotogrammetry and reverse engineering technology. Social smile images of white adolescents (N = 15, mean age = 15.4 ±1.5 years; range = 14-17 years) were obtained using 3dMDFlex (3dMD, Atlanta, Ga). Each participant was asked to produce 16 social smiles at 3-minute intervals. All images were obtained in natural head position. Alignment of images, segmentation of smile area, and 3-D deviation analysis were carried out using Geomagic Control software (3D Systems Inc, Cary, NC). A single image was taken as a reference, and the remaining 15 images were compared with the reference image to evaluate positive and negative deviations. The differences between the mean deviation limits of participants with the highest and the lowest deviations and the total mean deviations were evaluated using Bland-Altman Plots. Minimum and maximum deviations of a single image from the reference image were 0.34 and 2.69 mm, respectively. Lowest deviation between two images was within 0.5 mm and 1.54 mm among all participants (mean, 0.96 ± 0.21 mm), and the highest deviation was between 0.41 mm and 2.69 mm (mean, 1.53 ± 0.46 mm). For a single patient, when all alignments were considered together, the mean deviation was between 0.32 ± 0.10 mm and 0.59 ± 0.24 mm. Mean deviation for one image was between 0.14 and 1.21 mm. The range of reproducibility of the social smile presented individual variability, but this variation was not clinically significant or detectable under routine clinical observation.
Kotovskaia, A R; Koloteva, M I; Luk'ianiuk, V Iu; Stepanova, G P; Filatova, L M; Buĭlov, S P; Zhernavkov, A F; Kondratiuk, L L
2007-01-01
Analyzed were deviations in cardiac function in 29 cosmonauts with previous aviation and other occupations ranging of 29 to 61 y.o. who made 8- to 30-day space flights (totai number of flights = 34) between 1982 and 2006. The deviations were identified in ECG records collected during clinical selection, clinical physiological examination (CPE) before flight, insertion and deorbit in transport vehicles, and post-flight CPE. Based on the analysis, the cosmonauts were distributed into three groups. The first group (55.2% of the cosmonauts) did not exhibit noticeable shifts and unfavorable trends in ECG at any time of the period of observation. The second group (34.5%) showed some deviations during selection and pre-flight CPE that became more apparent in the period of deorbit and were still present in post-flight ECG records. The third group (10.3%) displayed health-threatening deviations in cardiac function during deorbit. These findings give start to important investigations with the purpose to define permissible medical risks and ensuing establishment and perfection of medical criteria for candidates to cosmonauts with certain health problems.
NASA Astrophysics Data System (ADS)
Žibret, Gorazd; Žibret, Lea
2017-03-01
High resolution digital models, combined with GIS or other terrain modelling software, allow many new possibilities in geoscience. In this paper we develop, describe and test a novel method, the GLA method, to detect active tectonic uplift or subsidence along river courses. It is a modification of Hack's SL-index method in order to overcome the disadvantages of the latter. The core assumption of the GLA method is that over geological time river profiles quickly adjust to follow an exponential decrease in elevation along the river course. Any large deviation can be attributed to active tectonic movement, or to disturbances in erosion/sedimentation processes caused by an anthropogenic structure (e.g. artificial dam). During the testing phase, the locations of identified deviations were compared to the locations of faults, identified on a 1:100,000 geological map. Results show that higher magnitude deviations are found within a maximum radius of 200 m from the fault, and the majority of detected deviations within a maximum radius of 600 m from faults or thrusts. However, these results are not the best that could be obtained because the geological map that was used (and the only one available for the area) is not of the appropriate scale, and was therefore not precise enough. Comparison of deviation magnitudes against PSInSAR measurements of vertical displacements in the vicinity revealed that in spite of the very few suitable points available, a good correlation between both independent methods was obtained (R2 = 0.68 for the E research area and R2 = 0.69 for the W research area). The GLA method was applied to the three test sites where previous studies have shown active tectonic movements. It shows that deviations occur at the intersections between active faults and river courses, as well as also correctly detected active uplift, attributed to the increased sedimentation rate above an artificial hydropower dam, and an increased erosion rate below. The method gives promising results, and it is acknowledged that the GLA method needs to be tested in other locations around the world.
Gait Deviations in Children With Osteogenesis Imperfecta Type I.
Garman, Christina R; Graf, Adam; Krzak, Joseph; Caudill, Angela; Smith, Peter; Harris, Gerald
2017-08-02
Osteogenesis imperfecta (OI) is a congenital connective tissue disorder often characterized by orthopaedic complications that impact normal gait. As such, mobility is of particular interest in the OI population as it is associated with multiple aspects of participation and quality of life. The purpose of the current study was to identify and describe common gait deviations in a large sample of individuals with type I OI and speculate the etiology with a goal of improving function. Gait analysis was performed on 44 subjects with type I (11.7±3.08 y old) and 30 typically developing controls (9.54±3.1 y old ). Spatial temporal, kinematic, and kinetic gait data were calculated from the Vicon Plug-in-Gait Model. Musculoskeletal modeling of the muscle tendon lengths (MTL) was done in OpenSim 3.3 to evaluate the MTL of the gastrocnemius and gluteus maximus. The gait deviation index, a dimensionless parameter that evaluates the deviation of 9 kinematic gait parameters from a control database, was also calculated. Walking speed, single support time, stride, and step length were lower and double support time was higher in the OI group. The gait deviation index score was lower and external hip rotation angle was higher in the OI group. Peak hip flexor, knee extensor and ankle plantarflexor moments, and power generation at the ankle were lower in the OI group. MTL analysis revealed no significant length discrepancies between the OI group and the typically developing group. Together, these findings provide a comprehensive description of gait characteristics among a group of individuals with type I OI. Such data inform clinicians about specific gait deviations in this population allowing clinicians to recommend more focused interventions. Level III-case-control study.
Identification of dynapenia in older adults through the use of grip strength t-scores.
Bohannon, Richard W; Magasi, Susan
2015-01-01
The aim of this study was to generate reference values and t-scores (1.0-2.5 standard deviations below average) for grip strength for healthy young adults and to examine the utility of t-scores from this group for the identification of dynapenia in older adults. Our investigation was a population-based, general community secondary analysis of cross-sectional grip strength data utilizing the NIH Toolbox Assessment norming sample. Participants consisted of community-dwelling adults, with age ranges of 20-40 years (n = 558) and 60-85 years (n = 390). The main outcome measure was grip strength using a Jamar plus dynamometer. Maximum grip strengths were consistent over the 20-40-year age group [men 108.0 (SD 22.6) pounds, women 65.8 (SD 14.6) pounds]. Comparison of older group grip strengths to those of the younger reference group revealed (depending on age strata) that 46.2-87.1% of older men and 50.0-82.4% of older women could be designated as dynapenic on the basis of t-scores. The use of reference value t-scores from younger adults is a promising method for determining dynapenia in older adults. © 2014 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chinsky, B; Patel, R; Roeske, J
Purpose: To evaluate the inherent accuracy of using a surface guided radiotherapy system (SGRT) in the setup and monitoring of patients receiving stereotactic radiosurgery with an open-face SRS immobilization system. Methods: An anthropomorphic head phantom was set up using the Qfix Encompass SRS Immobilization System on a Varian Edge with OSMS and Varian TrueBeam with AlignRT. The phantom was positioned at 0° gantry and couch. A reference image was acquired using the SGRT system and an ROI was created over the mask opening. The couch and gantry were rotated to different combinations focusing on clinically used SRS gantry/couch combinations andmore » those blocking the SGRT cameras. Perceived surface deviation by the SGRT system from the reference image was recorded. A Winston-Lutz test was performed on couch angles tested and used to exclude couch walkout. The deviation magnitude was calculated using translational values and rotational raw values were recorded. Results: The maximum couch walkouts were: 0.4mm (Edge) and 0.5mm (TB). Solely rotating the gantry resulted in a median couch deviation of 0.2mm and range of 0.1–0.3mm for both linacs. Only rotating the couch (0° gantry) resulted in median deviations of 0.6mm and 0.5mm with ranges of 0.3–1.0mm and 0.3–0.7mm for the Edge and TB, respectively. Combining gantry and couch rotations, the median deviations were 0.7mm and 0.9mm with ranges of 0.3–1.1mm and 0.2–1.9mm for the Edge and TB, respectively. Including all combinations, rotation, roll, and pitch median deviations ranged from 0.1–0.3° with pitch demonstrating consistently higher values and a maximum deviation of 1.0° (both linacs). Conclusion: SGRT is a reliable monitoring tool, though taking into account system fluctuations, 1mm is too restrictive a site tolerance to use with the Qfix Encompass mask. Gantry rotation has little effect on system fluctuation even with camera blockage, whereas couch rotation has a larger effect.« less
System and method of vehicle operating condition management
Sujan, Vivek A.; Vajapeyazula, Phani; Follen, Kenneth; Wu, An; Moffett, Barty L.
2015-10-20
A vehicle operating condition profile can be determined over a given route while also considering imposed constraints such as deviation from time targets, deviation from maximum governed speed limits, etc. Given current vehicle speed, engine state and transmission state, the present disclosure optimally manages the engine map and transmission to provide a recommended vehicle operating condition that optimizes fuel consumption in transitioning from one vehicle state to a target state. Exemplary embodiments provide for offline and online optimizations relative to fuel consumption. The benefit is increased freight efficiency in transporting cargo from source to destination by minimizing fuel consumption and maintaining drivability.
A product Pearson-type VII density distribution
NASA Astrophysics Data System (ADS)
Nadarajah, Saralees; Kotz, Samuel
2008-01-01
The Pearson-type VII distributions (containing the Student's t distributions) are becoming increasing prominent and are being considered as competitors to the normal distribution. Motivated by real examples in decision sciences, Bayesian statistics, probability theory and Physics, a new Pearson-type VII distribution is introduced by taking the product of two Pearson-type VII pdfs. Various structural properties of this distribution are derived, including its cdf, moments, mean deviation about the mean, mean deviation about the median, entropy, asymptotic distribution of the extreme order statistics, maximum likelihood estimates and the Fisher information matrix. Finally, an application to a Bayesian testing problem is illustrated.
Diagnostics for insufficiencies of posterior calculations in Bayesian signal inference.
Dorn, Sebastian; Oppermann, Niels; Ensslin, Torsten A
2013-11-01
We present an error-diagnostic validation method for posterior distributions in Bayesian signal inference, an advancement of a previous work. It transfers deviations from the correct posterior into characteristic deviations from a uniform distribution of a quantity constructed for this purpose. We show that this method is able to reveal and discriminate several kinds of numerical and approximation errors, as well as their impact on the posterior distribution. For this we present four typical analytical examples of posteriors with incorrect variance, skewness, position of the maximum, or normalization. We show further how this test can be applied to multidimensional signals.
Classification of deadlift biomechanics with wearable inertial measurement units.
O'Reilly, Martin A; Whelan, Darragh F; Ward, Tomas E; Delahunt, Eamonn; Caulfield, Brian M
2017-06-14
The deadlift is a compound full-body exercise that is fundamental in resistance training, rehabilitation programs and powerlifting competitions. Accurate quantification of deadlift biomechanics is important to reduce the risk of injury and ensure training and rehabilitation goals are achieved. This study sought to develop and evaluate deadlift exercise technique classification systems utilising Inertial Measurement Units (IMUs), recording at 51.2Hz, worn on the lumbar spine, both thighs and both shanks. It also sought to compare classification quality when these IMUs are worn in combination and in isolation. Two datasets of IMU deadlift data were collected. Eighty participants first completed deadlifts with acceptable technique and 5 distinct, deliberately induced deviations from acceptable form. Fifty-five members of this group also completed a fatiguing protocol (3-Repition Maximum test) to enable the collection of natural deadlift deviations. For both datasets, universal and personalised random-forests classifiers were developed and evaluated. Personalised classifiers outperformed universal classifiers in accuracy, sensitivity and specificity in the binary classification of acceptable or aberrant technique and in the multi-label classification of specific deadlift deviations. Whilst recent research has favoured universal classifiers due to the reduced overhead in setting them up for new system users, this work demonstrates that such techniques may not be appropriate for classifying deadlift technique due to the poor accuracy achieved. However, personalised classifiers perform very well in assessing deadlift technique, even when using data derived from a single lumbar-worn IMU to detect specific naturally occurring technique mistakes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Taghizadeh, Somayeh; Yang, Claus Chunli; R. Kanakamedala, Madhava; Morris, Bart; Vijayakumar, Srinivasan
2017-01-01
Purpose Magnetic resonance (MR) images are necessary for accurate contouring of intracranial targets, determination of gross target volume and evaluation of organs at risk during stereotactic radiosurgery (SRS) treatment planning procedures. Many centers use magnetic resonance imaging (MRI) simulators or regular diagnostic MRI machines for SRS treatment planning; while both types of machine require two stages of quality control (QC), both machine- and patient-specific, before use for SRS, no accepted guidelines for such QC currently exist. This article describes appropriate machine-specific QC procedures for SRS applications. Methods and materials We describe the adaptation of American College of Radiology (ACR)-recommended QC tests using an ACR MRI phantom for SRS treatment planning. In addition, commercial Quasar MRID3D and Quasar GRID3D phantoms were used to evaluate the effects of static magnetic field (B0) inhomogeneity, gradient nonlinearity, and a Leksell G frame (SRS frame) and its accessories on geometrical distortion in MR images. Results QC procedures found in-plane distortions (Maximum = 3.5 mm, Mean = 0.91 mm, Standard deviation = 0.67 mm, >2.5 mm (%) = 2) in X-direction (Maximum = 2.51 mm, Mean = 0.52 mm, Standard deviation = 0.39 mm, > 2.5 mm (%) = 0) and in Y-direction (Maximum = 13. 1 mm , Mean = 2.38 mm, Standard deviation = 2.45 mm, > 2.5 mm (%) = 34) in Z-direction and < 1 mm distortion at a head-sized region of interest. MR images acquired using a Leksell G frame and localization devices showed a mean absolute deviation of 2.3 mm from isocenter. The results of modified ACR tests were all within recommended limits, and baseline measurements have been defined for regular weekly QC tests. Conclusions With appropriate QC procedures in place, it is possible to routinely obtain clinically useful MR images suitable for SRS treatment planning purposes. MRI examination for SRS planning can benefit from the improved localization and planning possible with the superior image quality and soft tissue contrast achieved under optimal conditions. PMID:29487771
Fatemi, Ali; Taghizadeh, Somayeh; Yang, Claus Chunli; R Kanakamedala, Madhava; Morris, Bart; Vijayakumar, Srinivasan
2017-12-18
Purpose Magnetic resonance (MR) images are necessary for accurate contouring of intracranial targets, determination of gross target volume and evaluation of organs at risk during stereotactic radiosurgery (SRS) treatment planning procedures. Many centers use magnetic resonance imaging (MRI) simulators or regular diagnostic MRI machines for SRS treatment planning; while both types of machine require two stages of quality control (QC), both machine- and patient-specific, before use for SRS, no accepted guidelines for such QC currently exist. This article describes appropriate machine-specific QC procedures for SRS applications. Methods and materials We describe the adaptation of American College of Radiology (ACR)-recommended QC tests using an ACR MRI phantom for SRS treatment planning. In addition, commercial Quasar MRID 3D and Quasar GRID 3D phantoms were used to evaluate the effects of static magnetic field (B 0 ) inhomogeneity, gradient nonlinearity, and a Leksell G frame (SRS frame) and its accessories on geometrical distortion in MR images. Results QC procedures found in-plane distortions (Maximum = 3.5 mm, Mean = 0.91 mm, Standard deviation = 0.67 mm, >2.5 mm (%) = 2) in X-direction (Maximum = 2.51 mm, Mean = 0.52 mm, Standard deviation = 0.39 mm, > 2.5 mm (%) = 0) and in Y-direction (Maximum = 13. 1 mm , Mean = 2.38 mm, Standard deviation = 2.45 mm, > 2.5 mm (%) = 34) in Z-direction and < 1 mm distortion at a head-sized region of interest. MR images acquired using a Leksell G frame and localization devices showed a mean absolute deviation of 2.3 mm from isocenter. The results of modified ACR tests were all within recommended limits, and baseline measurements have been defined for regular weekly QC tests. Conclusions With appropriate QC procedures in place, it is possible to routinely obtain clinically useful MR images suitable for SRS treatment planning purposes. MRI examination for SRS planning can benefit from the improved localization and planning possible with the superior image quality and soft tissue contrast achieved under optimal conditions.
Genome-scan analysis for quantitative trait loci in an F2 tilapia hybrid.
Cnaani, A; Zilberman, N; Tinman, S; Hulata, G; Ron, M
2004-09-01
We searched for genetic linkage between DNA markers and quantitative trait loci (QTLs) for innate immunity, response to stress, biochemical parameters of blood, and fish size in an F2 population derived from an interspecific tilapia hybrid (Oreochromis mossambicusx O. aureus). A family of 114 fish was scanned for 40 polymorphic microsatellite DNA markers and two polymorphic genes, covering approximately 80% of the tilapia genome. These fish had previously been phenotyped for seven immune-response traits and six blood parameters. Critical values for significance were P <0.05 with the false discovery rate (FDR) controlled at 40%. The genome-scan analysis resulted in 35 significant marker-trait associations, involving 26 markers in 16 linkage groups. In a second experiment, nine markers were re-sampled in a second family of 79 fish of the same species hybrid. Seven markers (GM180, GM553, MHC-I, UNH848, UNH868, UNH898 and UNH925) in five linkage groups (LG 1, 3, 4, 22 and 23) were associated with stress response traits. An additional six markers (GM47, GM552, UNH208, UNH881, UNH952, UNH998) in five linkage groups (LG 4, 16, 19, 20 and 23) were verified for their associations with immune response traits, by linkage to several different traits. The portion of variance explained by each QTL was 11% on average, with a maximum of 29%. The average additive effect of QTLs was 0.2 standard deviation units of stress response traits and fish size, with a maximum of 0.33. In three linkage groups (LG 1, 3 and 23) markers were associated with stress response, body weight and sex determination, confirming the location of QTLs reported by several other studies.
Anthropometric and physiological profiles of sepak takraw players
Jawis, M; Singh, R; Singh, H; Yassin, M; Khanna, G
2005-01-01
Objectives: Anthropometric and physiological profiles of national sepak takraw players were determined. Methods: Thirty nine players, specialising in the three playing positions (tekong/server, feeder, and killer/spiker) were divided into three age categories of under 15 (U15), under 18 (U18), and under 23 (U23) years of age. Height, weight, percent body fat (%bf), maximum oxygen consumption (Vo2max), range of motion (ROM), back and leg strength, and heart rate, for the estimation of oxygen consumption during matches, were recorded. Statistical analysis was performed using one way ANOVA for independent measurements and data are presented as mean±standard deviation. Results: The U23 players were significantly taller and heavier with significantly better ROM of the neck, trunk, and ankle joints and back and leg strength than the U15 players. No significant difference was found in %bf between the three age categories. Mean maximum heart rate during exercise was significantly higher in the U15 group when compared to the U18 and U23 groups (p<0.05). Mean Vo2max was similar between the three groups. Estimated oxygen consumption during matches was 69.1%, 68.5%, and 56.4% of Vo2max in the killer, tekong, and the feeder groups, respectively. Conclusions: The mean height, body weight, and cardiopulmonary capacities of the players were within the Malaysian population norms, but were somewhat lower than those of players of other court games from other countries. %bf was also lower in these players. This study provides the much needed anthropometric and physiological data of sepak takraw players for further development of this sport. PMID:16244191
Shear thinning effects on blood flow in straight and curved tubes
NASA Astrophysics Data System (ADS)
Cherry, Erica M.; Eaton, John K.
2013-07-01
Simulations were performed to determine the magnitude and types of errors one can expect when approximating blood in large arteries as a Newtonian fluid, particularly in the presence of secondary flows. This was accomplished by running steady simulations of blood flow in straight and curved tubes using both Newtonian and shear-thinning viscosity models. In the shear-thinning simulations, the viscosity was modeled as a shear rate-dependent function fit to experimental data. Simulations in straight tubes were modeled after physiologically relevant arterial flows, and flow parameters for the curved tube simulations were chosen to examine a variety of secondary flow strengths. The diameters ranged from 1 mm to 10 mm and the Reynolds numbers from 24 to 1500. Pressure and velocity data are reported for all simulations. In the straight tube simulations, the shear-thinning flows had flattened velocity profiles and higher pressure gradients compared to the Newtonian simulations. In the curved tube flows, the shear-thinning simulations tended to have blunted axial velocity profiles, decreased secondary flow strengths, and decreased axial vorticity compared to the Newtonian simulations. The cross-sectionally averaged pressure drops in the curved tubes were higher in the shear-thinning flows at low Reynolds number but lower at high Reynolds number. The maximum deviation in secondary flow magnitude averaged over the cross sectional area was 19% of the maximum secondary flow and the maximum deviation in axial vorticity was 25% of the maximum vorticity.
NASA Astrophysics Data System (ADS)
Li, T.; Griffiths, W. D.; Chen, J.
2017-11-01
The Maximum Likelihood method and the Linear Least Squares (LLS) method have been widely used to estimate Weibull parameters for reliability of brittle and metal materials. In the last 30 years, many researchers focused on the bias of Weibull modulus estimation, and some improvements have been achieved, especially in the case of the LLS method. However, there is a shortcoming in these methods for a specific type of data, where the lower tail deviates dramatically from the well-known linear fit in a classic LLS Weibull analysis. This deviation can be commonly found from the measured properties of materials, and previous applications of the LLS method on this kind of dataset present an unreliable linear regression. This deviation was previously thought to be due to physical flaws ( i.e., defects) contained in materials. However, this paper demonstrates that this deviation can also be caused by the linear transformation of the Weibull function, occurring in the traditional LLS method. Accordingly, it may not be appropriate to carry out a Weibull analysis according to the linearized Weibull function, and the Non-linear Least Squares method (Non-LS) is instead recommended for the Weibull modulus estimation of casting properties.
Effect of Spring-in Deviation on Fatigue Life of Composite Elevator Assembly
NASA Astrophysics Data System (ADS)
Wang, Hua
2017-12-01
The spring-in deviation results in the extra stresses around the joints of the composite C-beam and metallic parts when they are assembled together. These extra stresses affect the composite elevator's fatigue life, which should be explored with the fatigue experimentation. The paper presents the experimental investigation on the effect of spring-in deviation on the fatigue life of the composite elevator assembly. The investigation seeks to build the relationship between the spring-in and the fatigue life in order to determine the spring-in threshold during the course of assembling. The phenomenological model of the composite C-beam is constructed to predict the stresses around the joints. Based on the predicted spring-in induced stresses around the joints, pre-stresses are precisely added to the fatigue specimen when conducting the fatigue experiment. At last, the relationship curve of the spring-in on the composite C-beam's fatigue life is obtained from the experimental data. Giving the fatigue life accepting limits, the maximum accepting spring-in deviation during the course of assembling could be obtained from the relationship curve. The reported work will enhance the understanding of assembling the composites with spring-in deviation in the civil aircraft industry.
Structural Brain Damage and Upper Limb Kinematics in Children with Unilateral Cerebral Palsy.
Mailleux, Lisa; Simon-Martinez, Cristina; Klingels, Katrijn; Jaspers, Ellen; Desloovere, Kaat; Demaerel, Philippe; Fiori, Simona; Guzzetta, Andrea; Ortibus, Els; Feys, Hilde
2017-01-01
Background: In children with unilateral cerebral palsy (uCP) virtually nothing is known on the relation between structural brain damage and upper limb (UL) kinematics quantified with three-dimensional movement analysis (3DMA). This explorative study aimed to (1) investigate differences in UL kinematics between children with different lesion timings, i.e., periventricular white matter (PWM) vs. cortical and deep gray matter (CDGM) lesions and (2) to explore the relation between UL kinematics and lesion location and extent within each lesion timing group. Methods: Forty-eight children (age 10.4 ± 2.7 year; 29 boys; 21 right-sided; 33 PWM; 15 CDGM) underwent an UL 3DMA during a reach-to-grasp task. Spatiotemporal parameters [movement duration, (timing of) maximum velocity, trajectory straightness], the Arm Profile Score (APS) and Arm Variable Scores (AVS) were extracted. The APS and AVS refer to the total amount of movement pathology and movement deviations of the wrist, elbow, shoulder, scapula and trunk respectively. Brain lesion location and extent were scored based on FLAIR-images using a semi-quantitative MRI-scale. Results: Children with CDGM lesions showed more aberrant spatiotemporal parameters ( p < 0.03) and more movement pathology (APS, p = 0.003) compared to the PWM group, mostly characterized by increased wrist flexion ( p = 0.01). In the CDGM group, moderate to high correlations were found between lesion location and extent and duration, timing of maximum velocity and trajectory straightness ( r = 0.53-0.90). Lesion location and extent were further moderately correlated with distal UL movement pathology (wrist flexion/extension, elbow pronation/supination, elbow flexion/extension; r = 0.50-0.65) and with the APS ( r = 0.51-0.63). In the PWM group, only a few and low correlations were observed, mostly between damage to the PLIC and higher AVS of elbow flexion/extension, shoulder elevation and trunk rotation ( r = 0.35-0.42). Regression analysis revealed damage to the temporal lobe with lesion timing as interactor (27%, p = 0.002) and the posterior limb of the internal capsule (PLIC) (7%, p = 0.04) as the strongest predictors, explaining 34% of the variance in APS. Conclusion: UL kinematic deviations are more influenced by lesion location and extent in children with later (CDGM) versus earlier lesions (PWM), except for proximal movement pathology. Damage to the PLIC is a significant predictor for UL movement pathology irrespective of lesion timing.
Ginat, Daniel T; Mangla, Rajiv; Yeaney, Gabrielle; Schaefer, Pamela W; Wang, Henry
2012-08-01
To determine whether there is a correlation between vascular endothelial growth factor (VEGF) expression and cerebral blood flow (CBV) measurements in dynamic contrast-enhanced susceptibility perfusion magnetic resonance imaging (MRI) and to correlate the perfusion characteristics in high- versus low-grade meningiomas. A total of 48 (24 high-grade and 24 low-grade) meningiomas with available dynamic susceptibility-weighted MRI were retrospectively reviewed for maximum CBV and semiquantitative VEGF immunoreactivity. Correlation between normalized CBV and VEGF was made using the Spearman rank test and comparison between CBV in high- versus low-grade meningiomas was made using the Wilcoxon test. There was a significant (P = .01) correlation between normalized maximum CBV and VEGF scores with a Spearman correlation coefficient of 0.37. In addition, there was a significant (P < .01) difference in normalized maximum CBV ratios between high-grade meningiomas (mean 12.6; standard deviation 5.2) and low-grade meningiomas (mean 8.2; standard deviation 5.2). The data suggest that CBV accurately reflects VEGF expression and tumor grade in meningiomas. Perfusion-weighted MRI can potentially serve as a useful biomarker for meningiomas, pending prospective studies. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
Seymen, Gülin; Turgut, Zeynep; Berk, Gizem; Bodur, Ayşen
2013-01-01
Background: Implant bed preparation with laser is taken into consideration owing to the increased interest in use of lasers in hard tissue surgery. The purpose of this study is to determine the deviations in the position and inclination between the planned and prepared implant beds with Erbium, Chromium doped Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser using stereolithographic (SLA) surgical guides. Methods: After 3-dimensional (3D) imaging of six sheep lower jaws, computed tomography (CT) images were transformed into 3D models. Locations of implant beds were determined on these models. Two implant beds in each half jaw were prepared with an Er,Cr:YSGG laser system and a conventional drilling method using a total of 12 SLA surgical guides. A new CT was taken to analyze the deviation values between planned and prepared implant beds. Finally, a software program was used to superimpose the images on 3D models, then the laser and conventional drilling groups were compared. Results: Differences of mean angular deviations between the planned and prepared implant beds were 5.17±4.91° in the laser group and 2.02±1.94° in the conventional drilling group.The mean coronal deviation values were found to be 0.48±0.25 mm and 0.23±0.14 mm in the laser group and conventional drilling group, respectively. While the mean deviation at the apex between the planned and prepared implant beds were 0.70±0.26 mm and 0.26±0.08 ,the mean vertical deviations were 0.06±0.15 mm and 0.02±0.05 mm for the laser group and the conventional drilling group, respectively. Conclusion: It is possible to prepare an implant bed properly with the aid of Er,Cr:YSGGlaser by using SLA surgical guide. PMID:25606303
Li, W T; Chen, X Z; Tu, W J; Huang, Z Z; Chang, L H; Wang, J; Zhang, G H
2016-09-07
Objective: To investigate the psychopathological characteristics in patients with deviation of nasal septum. Methods: Between May 2015 and December 2015, fourty-four patients with deviated nasal septum and 37 patients with vocal cord polyp as control were included in this study. Psychological characteristics were evaluated by a series of questionnaire instruments including symptom checklist-90 (SCL-90), self-rating depression scale (SDS) and self-rating anxiety scale (SAS). Visual analogue scale (VAS) and rhinomanometry through front nostril were used to evaluate nasal symptom. The correlation between psychological characteristics and nasal symptom was evaluated. SPSS 20.0 software was used to analyze the data. Results: The SCL-90 score in nasal septal deviation group was 130.4±48.3. The total score and total average score of SCL-90 had no significant difference between nasal septal deviation group and the Chinese standard or control group( t value was 0.469, 0.112, 1.575, 1.564, respectively, all P >0.05). The scores of somatization, depression and anxiety factors in nasal septal deviation group were higher than control group ( t value was 2.380, 2.133, 1.969, respectively, all P <0.05). The proportion of positive patients in these three factors between nasal septal deviation group and control group had significant differences (χ 2 value was 11.585, 9.610, 5.429, respectively, all P <0.05). The scores of SDS and SAS in nasal septal deviation group were 46.0±10.6 and 43.0±10.2, which were higher than that in the Chinese standard and control group ( t value was 5.342, 6.236, 1.476, 3.013, respectively, all P <0.05). There were 9 patients companying with depression or anxiety (20.5%, 20.5%, respectively) and 5 patients companying with depression and anxiety in nasal septal deviation group (11.4%). There were positive correlation not only between the scores of SDS and the depression factor of SCL-90 but also between the scores of SAS and the anxiety factor of SCL-90 ( Z =0.415, P =0.005, Z =0.445, P =0.002, respectively). The scores of SDS and SAS had positive correlation ( Z =0.392, P =0.008). The VAS score of nasal obstruction was 6.0±3.2. The rhinomanometry in inspiratory and expiratory phase were (0.202±0.140) kPa·S/cm 3 and (0.230±0.161) kPa·S/cm 3 . Besides the positive correlation between the rhinomanometry in inspiratory phase and SDS ( Z =0.332, P =0.045), the psychological scores, including SCL-90 score, depression, anxiety factors score, SAS and SDS, had no correlation with VAS scores and rhinomanometry ( r value was -0.030, -0.052, -0.026, 0.107, 0.185, 0.066, 0.160, 0.203, respectively, all P >0.05). Conclusions: High prevalence of depression and anxiety is found in patients with deviation of nasal septum. The SCL-90 score is consistent with SDS and SAS. Besides the positive correlation between the rhinomanometry in inspiratory phase and SDS, the psychological scores (SCL-90 score, depression, anxiety factors score, SAS and SDS) have no correlation with VAS score and rhinomanometry.
Li, YuePing; Sun, LiLi; Zhang, Wei; Zhao, KanXing
2016-10-01
To compare surgical results of augmented and nonaugmented modified Knapp procedure, for the treatment of nonrestrictive double elevator palsies (DEP). The medical records of patients with congenital DEP were reviewed retrospectively. Patients were divided into three treatment groups: standard transposition (group A), Foster transposition (group B), and resection transposition (group C). Pre- and postoperative vertical deviation in primary position, ocular motility, and binocular vision were compared. Thirty patients were enrolled. The pre- and postoperative deviations in group A were 34.7 Δ ± 8.6 Δ and 6.5 Δ ± 6.5 Δ ; in group B, 38.6 Δ ± 14.6 Δ and 5.7 Δ ± 9.3 Δ ; and in group C, 43.1 Δ ± 10.3 Δ and 8.5 Δ ± 6.1 Δ . The corrected vertical deviation of group B (32.9 Δ ± 5.7 Δ ) and group C (34.6 Δ ± 5.0 Δ ) were greater than that of group A (28.1 Δ ± 3.6 Δ ; P = 0.03, 0.002). The pre- and postoperative measures of upgaze in group A were -3.7 and -1.8; in group B, -4.0 and -1.3; and in group C, -3.6 and -2.0. The average improved upgaze in group B (2.6 ± 0.5) was statistically significantly better than that in group A (1.9 ± 0.6) and group C (1.5 ± 0.5; P = 0.03, 0.002). There was no significant difference in the surgical effect on downgaze in three groups (P > 0.05). The surgical outcome was satisfactory in 19 (63.3%) patients with preoperative vertical devation of ≤40 Δ . All transpositions are reasonably effective in treating vertical deviations of <35 Δ without obviously limiting downgaze in DEP. Augmented procedures could correct greater vertical deviation of 30 Δ -40 Δ . The Foster transposition demonstrates the strongest effect in improving upgaze. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Evaluating Silent Reading Performance with an Eye Tracking System in Patients with Glaucoma
Murata, Noriaki; Fukuchi, Takeo
2017-01-01
Objective To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system. Methods Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24–2 and 10–2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye. Results There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24–2 right mean deviation (rs = -0.280, P = 0.049), 24–2 right visual field index (rs = -0.306, P = 0.030), 24–2 worse visual field index (rs = -0.304, P = 0.032), and 10–2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10–2 left mean deviation (rs = -0.294, P = 0.045) and 10–2 worse mean deviation (rs = -0.306, P = 0.037), respectively. Conclusions The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading. PMID:28095478
An Ambulatory Method of Identifying Anterior Cruciate Ligament Reconstructed Gait Patterns
Patterson, Matthew R.; Delahunt, Eamonn; Sweeney, Kevin T.; Caulfield, Brian
2014-01-01
The use of inertial sensors to characterize pathological gait has traditionally been based on the calculation of temporal and spatial gait variables from inertial sensor data. This approach has proved successful in the identification of gait deviations in populations where substantial differences from normal gait patterns exist; such as in Parkinsonian gait. However, it is not currently clear if this approach could identify more subtle gait deviations, such as those associated with musculoskeletal injury. This study investigates whether additional analysis of inertial sensor data, based on quantification of gyroscope features of interest, would provide further discriminant capability in this regard. The tested cohort consisted of a group of anterior cruciate ligament reconstructed (ACL-R) females and a group of non-injured female controls, each performed ten walking trials. Gait performance was measured simultaneously using inertial sensors and an optoelectronic marker based system. The ACL-R group displayed kinematic and kinetic deviations from the control group, but no temporal or spatial deviations. This study demonstrates that quantification of gyroscope features can successfully identify changes associated with ACL-R gait, which was not possible using spatial or temporal variables. This finding may also have a role in other clinical applications where small gait deviations exist. PMID:24451464
The effects of auditory stimulation with music on heart rate variability in healthy women.
Roque, Adriano L; Valenti, Vitor E; Guida, Heraldo L; Campos, Mônica F; Knap, André; Vanderlei, Luiz Carlos M; Ferreira, Lucas L; Ferreira, Celso; Abreu, Luiz Carlos de
2013-07-01
There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level.
The effects of auditory stimulation with music on heart rate variability in healthy women
Roque, Adriano L.; Valenti, Vitor E.; Guida, Heraldo L.; Campos, Mônica F.; Knap, André; Vanderlei, Luiz Carlos M.; Ferreira, Lucas L.; Ferreira, Celso; de Abreu, Luiz Carlos
2013-01-01
OBJECTIVES: There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. METHODS: We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. RESULTS: The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. CONCLUSION: We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level. PMID:23917660
Low intensity vibration of ankle muscles improves balance in elderly persons at high risk of falling
Toosizadeh, Nima; Mohler, Jane
2018-01-01
In our study we examined postural performance of young healthy persons (HY), elderly healthy persons (HE), and elderly persons at high risk of falling (FR). Anterio-posterior (AP) and medio-lateral (ML) ankle and hip angular deviations, as well as linear displacements of the center of mass (COM) were assessed in persons standing with eyes either open or closed, while none, and 40 and 30 Hz vibrations were applied bilaterally to the ankle muscle gastrocnemius. During quiet standing with eyes open, balance parameters in FR group differed from those in healthy groups. ML ankle and hip angular deviations, as well as COM linear displacements were noticeably larger in FR group. During quiet standing with eyes closed, all balance parameters in participants of all groups had a clear trend to increase. During standing with eyes open, 40 Hz vibration increased all but one balance parameter within HY group, ankle angular deviations in HE group, but none in FR group. In response to 30 Hz vibration, only ankle angular deviations and COM linear displacements increased in HY group. There were no changes in both elderly groups. During standing with eyes closed, 40 and 30 Hz vibrations did not produce consistent changes in balance parameters in HY and HE groups. In FR persons, 40 Hz vibration did not change balance parameters. However, in FR groups, 30 Hz vibration decreased ankle and hip angular deviations, and COM linear displacements. The major result of the study is a finding that low intensity vibration of ankle muscles makes balance better in elderly persons at high risk of falling. This result is clinically relevant because it suggests that applying mild vibration to ankle muscles while standing and walking might benefit elderly persons, improving their postural performance and reducing a risk of unexpected falls. PMID:29579098
[Estimation of Maximum Entrance Skin Dose during Cerebral Angiography].
Kawauchi, Satoru; Moritake, Takashi; Hayakawa, Mikito; Hamada, Yusuke; Sakuma, Hideyuki; Yoda, Shogo; Satoh, Masayuki; Sun, Lue; Koguchi, Yasuhiro; Akahane, Keiichi; Chida, Koichi; Matsumaru, Yuji
2015-09-01
Using radio-photoluminescence glass dosimeter, we measured the entrance skin dose (ESD) in 46 cases and analyzed the correlations between maximum ESD and angiographic parameters [total fluoroscopic time (TFT); number of digital subtraction angiography (DSA) frames, air kerma at the interventional reference point (AK), and dose-area product (DAP)] to estimate the maximum ESD in real time. Mean (± standard deviation) maximum ESD, dose of the right lens, and dose of the left lens were 431.2 ± 135.8 mGy, 33.6 ± 15.5 mGy, and 58.5 ± 35.0 mGy, respectively. Correlation coefficients (r) between maximum ESD and TFT, number of DSA frames, AK, and DAP were r=0.379 (P<0.01), r=0.702 (P<0.001), r=0.825 (P<0.001), and r=0.709 (P<0.001), respectively. AK was identified as the most useful parameter for real-time prediction of maximum ESD. This study should contribute to the development of new diagnostic reference levels in our country.
Ramoutar, Darryl N; Crosnier, Emilie A; Shivji, Faiz; Miles, Anthony W; Gill, Harinderjit S
2017-05-01
Most femoral components used now for total hip arthroplasty are modular, requiring a strong connection at assembly. The aim of this study was to assess the effect of assembly force on the strength of head-trunnion interface and to measure the initial displacement of the head on the trunnion with different assembly forces. Three assembly load levels were assessed (A: 2 kN, B: 4 kN, C: 6 kN) with 4 implants in each group. The stems were mounted in a custom rig and the respective assembly loads were applied to the head at a constant rate of 0.05 kN/s (ISO7260-10:2003). Load levels were recorded during assembly. Head displacement was measured with a laser sensor. The disassembly force was determined by a standard pull-off test. The maximum head displacement on the trunnion was significantly different between the 2 kN group and the other 2 groups (4 kN, 6 kN, P = .029), but not between the 4 kN and 6 kN groups (P = .89). The disassembly forces between the 3 groups were significantly different (mean ± standard deviation, A: 1316 ± 223 kN; B: 2224 ± 151 kN; C: 3965 ± 344 kN; P = .007), with increasing assembly load leading to a higher pull-off force. For the 4 kN and 6 kN groups, a first peak of approximately 2.5 kN was observed on the load recordings during assembly before the required assembly load was eventually reached corresponding to sudden increase in head displacement to approximately 150 μm. An assembly force of 2 kN may be too low to overcome the frictional forces needed to engage the head and achieve maximum displacement on the trunnion and thus an assembly load of greater than 2.5 kN is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.
Mediastinal hemorrhage: An evaluation of radiographic manifestations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodring, J.H.; Loh, F.K.; Kryscio, R.J.
1984-04-01
Eleven common radiographic signs of mediastinal hemorrhage were evaluated by two observers for the following three patient groups: normal subjects, patients with mediastinal hemorrhage and no arterial injury, and patients with major thoracic arterial injury. Supine chest radiographs were studied in all cases. Four major conclusions can be made based upon these finding. M/C ratio (mediastinal width to chest width), tracheal deviation, left hemothorax, paraspinal line widening, and aorto-pulmonary window opacification do not reliably separate these three groups of patients. The diagnosis of mediastinal hemorrhage may be made if the aortic contour is abnormal or if one of the followingmore » signs is positive: abnormal mediastinal width, apical cap, widening of the right paratracheal stripe, or deviation of the nasogastric tube. Due to interobserver variation, there is good agreement between observers for the following four signs only: transverse mediastinal width, tracheal deviation, nasogastric tube deviation, nasogastric tube deviation, and right paratracheal stripe widening.« less
4-(4-Methoxyphenyl)-2-methylbut-3-yn-2-ol
Eissmann, Frank; Kafurke, Uwe; Weber, Edwin
2010-01-01
The molecular structure of the title compound, C12H14O2, features a nearly coplanar arrangement including the aromatic ring, the C C—C group and the ether O atom. The maximum deviation from the least-squares plane of these ten atoms is 0.0787 (8) Å for the ether O atom. In the crystal, molecules are connected via O—H⋯O hydrogen bonds (involving the hydroxy O atom both as hydrogen-bond donor and acceptor) and weaker (aryl)C—H⋯π(aryl) contacts, leading to the formation of strands running parallel to the b axis. Further stabilization results from weaker (methyl)C—H⋯π(acetylene) interactions between different strands. PMID:21588063
Crystal structure of (7-methyl-2-oxo-2H-chromen-4-yl)methyl piperidine-1-carbodithioate
Roopashree, K. R.; Meenakshi, T. G.; Kumar, K. Mahesh; Kotresh, O.; Devarajegowda, H. C.
2015-01-01
In the title compound, C17H19NO2S2, the 2H-chromene ring system is nearly planar, with a maximum deviation of 0.0383 (28) Å, and the piperidine ring adopts a chair conformation. The 2H-chromene ring makes dihedral angles of 32.89 (16) and 67.33 (8)°, respectively, with the mean planes of the piperidine ring and the carbodithioate group. In the crystal, C—H⋯O and weak C—H⋯S hydrogen bonds link the molecules into chains along [001]. The crystal structure also features C—H⋯π and π–π interactions, with a centroid–centroid distance of 3.7097 (17) Å. PMID:26396821
Schrems, W A; Laemmer, R; Hoesl, L M; Horn, F K; Mardin, C Y; Kruse, F E; Tornow, R P
2011-10-01
To investigate the influence of atypical retardation pattern (ARP) on the distribution of peripapillary retinal nerve fibre layer (RNFL) thickness measured with scanning laser polarimetry in healthy individuals and to compare these results with RNFL thickness from spectral domain optical coherence tomography (OCT) in the same subjects. 120 healthy subjects were investigated in this study. All volunteers received detailed ophthalmological examination, GDx variable corneal compensation (VCC) and Spectralis-OCT. The subjects were divided into four subgroups according to their typical scan score (TSS): very typical with TSS=100, typical with 99 ≥ TSS ≥ 91, less typical with 90 ≥ TSS ≥ 81 and atypical with TSS ≤ 80. Deviations from very typical normal values were calculated for 32 sectors for each group. There was a systematic variation of the RNFL thickness deviation around the optic nerve head in the atypical group for the GDxVCC results. The highest percentage deviation of about 96% appeared temporal with decreasing deviation towards the superior and inferior sectors, and nasal sectors exhibited a deviation of 30%. Percentage deviations from very typical RNFL values decreased with increasing TSS. No systematic variation could be found if the RNFL thickness deviation between different TSS-groups was compared with the OCT results. The ARP has a major impact on the peripapillary RNFL distribution assessed by GDx VCC; thus, the TSS should be included in the standard printout.
Chen, Yan; Fang, Zheng; Wei, Ping
2009-01-01
The molecule of the title compound, C4H2Cl2N2, is almost planar [maximum deviation = 0.013 (3) Å for a Cl atom]. In the crystal structure, intermolecular C—H⋯N interactions link the molecules into chains. PMID:21583278
Syh, J; Patel, B; Syh, J; Wu, H; Rosen, L; Durci, M; Katz, S; Sibata, C
2012-06-01
To evaluate the characteristics of commercial-grade flatbed scanners and medical-grade scanners for radiochromic EBT film dosimetry. Performance aspects of a Vidar Dosimetry Pro Advantage (Red), Epson 750 Pro, Microtek ArtixScan 1800f, and Microtek ScanMaker 8700 scanner for EBT2 Gafchromic film were evaluated in the categories of repeatability, maximum distinguishable optical density (OD) differentiation, OD variance, and dose curve characteristics. OD step film by Stouffer Industries containing 31 steps ranging from 0.05 to 3.62 OD was used. EBT films were irradiated with dose ranging from 20 to 600 cGy in 6×6 cm 2 field sizes and analyzed 24 hours later using RIT113 and Tomotherapy Film Analyzer software. Scans were performed in transmissive mode, landscape orientation, 16-bit image. The mean and standard deviation Analog to Digital (A/D) scanner value was measured by selecting a 3×3 mm 2 uniform area in the central region of each OD step from a total of 20 scans performed over several weeks. Repeatability was determined from the variance of OD step 0.38. Maximum distinguishable OD was defined as the last OD step whose range of A/D values does not overlap with its neighboring step. Repeatability uncertainty ranged from 0.1% for Vidar to 4% for Epson. Average standard deviation of OD steps ranged from 0.21% for Vidar to 6.4% for ArtixScan 1800f. Maximum distinguishable optical density ranged from 3.38 for Vidar to 1.32 for ScanMaker 8700. A/D range of each OD step corresponds to a dose range. Dose ranges of OD steps varied from 1% for Vidar to 20% for ScanMaker 8700. The Vidar exhibited a dose curve that utilized a broader range of OD values than the other scanners. Vidar exhibited higher maximum distinguishable OD, smaller variance in repeatability, smaller A/D value deviation per OD step, and a shallower dose curve with respect to OD. © 2012 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Edvardsson, A.; Ceberg, S.
2013-06-01
The aim of this study was 1) to investigate interfraction set-up uncertainties for patients treated with respiratory gating for left-sided breast cancer, 2) to investigate the effect of the inter-fraction set-up on the absorbed dose-distribution for the target and organs at risk (OARs) and 3) optimize the set-up correction strategy. By acquiring multiple set-up images the systematic set-up deviation was evaluated. The effect of the systematic set-up deviation on the absorbed dose distribution was evaluated by 1) simulation in the treatment planning system and 2) measurements with a biplanar diode array. The set-up deviations could be decreased using a no action level correction strategy. Not using the clinically implemented adaptive maximum likelihood factor for the gating patients resulted in better set-up. When the uncorrected set-up deviations were simulated the average mean absorbed dose was increased from 1.38 to 2.21 Gy for the heart, 4.17 to 8.86 Gy to the left anterior descending coronary artery and 5.80 to 7.64 Gy to the left lung. Respiratory gating can induce systematic set-up deviations which would result in increased mean absorbed dose to the OARs if not corrected for and should therefore be corrected for by an appropriate correction strategy.
Change in mean temperature as a predictor of extreme temperature change in the Asia-Pacific region
NASA Astrophysics Data System (ADS)
Griffiths, G. M.; Chambers, L. E.; Haylock, M. R.; Manton, M. J.; Nicholls, N.; Baek, H.-J.; Choi, Y.; della-Marta, P. M.; Gosai, A.; Iga, N.; Lata, R.; Laurent, V.; Maitrepierre, L.; Nakamigawa, H.; Ouprasitwong, N.; Solofa, D.; Tahani, L.; Thuy, D. T.; Tibig, L.; Trewin, B.; Vediapan, K.; Zhai, P.
2005-08-01
Trends (1961-2003) in daily maximum and minimum temperatures, extremes and variance were found to be spatially coherent across the Asia-Pacific region. The majority of stations exhibited significant trends: increases in mean maximum and mean minimum temperature, decreases in cold nights and cool days, and increases in warm nights. No station showed a significant increase in cold days or cold nights, but a few sites showed significant decreases in hot days and warm nights. Significant decreases were observed in both maximum and minimum temperature standard deviation in China, Korea and some stations in Japan (probably reflecting urbanization effects), but also for some Thailand and coastal Australian sites. The South Pacific convergence zone (SPCZ) region between Fiji and the Solomon Islands showed a significant increase in maximum temperature variability.Correlations between mean temperature and the frequency of extreme temperatures were strongest in the tropical Pacific Ocean from French Polynesia to Papua New Guinea, Malaysia, the Philippines, Thailand and southern Japan. Correlations were weaker at continental or higher latitude locations, which may partly reflect urbanization.For non-urban stations, the dominant distribution change for both maximum and minimum temperature involved a change in the mean, impacting on one or both extremes, with no change in standard deviation. This occurred from French Polynesia to Papua New Guinea (except for maximum temperature changes near the SPCZ), in Malaysia, the Philippines, and several outlying Japanese islands. For urbanized stations the dominant change was a change in the mean and variance, impacting on one or both extremes. This result was particularly evident for minimum temperature.The results presented here, for non-urban tropical and maritime locations in the Asia-Pacific region, support the hypothesis that changes in mean temperature may be used to predict changes in extreme temperatures. At urbanized or higher latitude locations, changes in variance should be incorporated.
In vitro marginal fit of three all-ceramic crown systems.
Yeo, In-Sung; Yang, Jae-Ho; Lee, Jai-Bong
2003-11-01
Studies on marginal discrepancies of single restorations using various systems and materials have resulted in statistical inferences that are ambiguous because of small sample sizes and limited numbers of measurements per specimen. The purpose of this study was to compare the marginal adaptation of single anterior restorations made using different systems. The in vitro marginal discrepancies of 3 different all-ceramic crown systems (Celay In-Ceram, conventional In-Ceram, and IPS Empress 2 layering technique), and a control group of metal ceramic restorations were evaluated and compared by measuring the gap dimension between the crowns and the prepared tooth at the marginal opening. The crowns were made for 1 extracted maxillary central incisor prepared with a 1-mm shoulder margin and 6-degree tapered walls by milling. Thirty crowns per system were fabricated. Crown measurements were recorded with an optical microscope, with an accuracy of +/-0.1 microm, at 50 points spaced approximately 400 microm along the circumferential margin. The criterion of 120 microm was used as the maximum clinically acceptable marginal gap. Mean gap dimensions and standard deviations were calculated for marginal opening. The data were analyzed with a 1-way analysis of variance (alpha=.05). Mean gap dimensions and standard deviations at the marginal opening for the incisor crowns were 87 +/- 34 microm for control, 83 +/- 33 microm for Celay In-Ceram, 112 +/- 55 microm for conventional In-Ceram, and 46 +/- 16 microm for the IPS Empress 2 layering technique. Significant differences were found among the crown groups (P<.05). Compared with the control group, the IPS Empress 2 group had significantly smaller marginal discrepancies (P<.05), and the conventional In-Ceram group exhibited significantly greater marginal discrepancies (P<.05). There was no significant difference between the Celay In-Ceram and the control group. Within the limitations of this study, the marginal discrepancies were all within the clinically acceptable standard set at 120 microm. However, the IPS Empress 2 system showed the smallest and most homogeneous gap dimension, whereas the conventional In-Ceram system presented the largest and more variable gap dimension compared with the metal ceramic (control) restoration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garcia-Garduno, O. A.; Larraga-Gutierrez, J. M.; Celis, M. A.
2006-09-08
An acrylic phantom was designed and constructed to assess the geometrical accuracy of CT, MRI and PET images for stereotactic radiotherapy (SRT) and radiosurgery (SRS) applications. The phantom was suited for each image modality with a specific tracer and compared with CT images to measure the radial deviation between the reference marks in the phantom. It was found that for MRI the maximum mean deviation is 1.9 {+-} 0.2 mm compared to 2.4 {+-} 0.3 mm reported for PET. These results will be used for margin outlining in SRS and SRT treatment planning.
Real-gas effects associated with one-dimensional transonic flow of cryogenic nitrogen
NASA Technical Reports Server (NTRS)
Adcock, J. B.
1976-01-01
Real gas solutions for one-dimensional isentropic and normal-shock flows of nitrogen were obtained for a wide range of temperatures and pressures. These calculations are compared to ideal gas solutions and are presented in tables. For temperatures (300 K and below) and pressures (1 to 10 atm) that cover those anticipated for transonic cryogenic tunnels, the solutions are analyzed to obtain indications of the magnitude of inviscid flow simulation errors. For these ranges, the maximum deviation of the various isentropic and normal shock parameters from the ideal values is about 1 percent or less, and for most wind tunnel investigations this deviation would be insignificant.
Global Body Posture Evaluation in Patients with Temporomandibular Joint Disorder
Saito, Eliza Tiemi; Akashi, Paula Marie Hanai; de Camargo Neves Sacco, Isabel
2009-01-01
AIM: To identify the relationship between anterior disc displacement and global posture (plantar arches, lower limbs, shoulder and pelvic girdle, vertebral spine, head and mandibles). Common signs and symptoms of anterior disc displacement were also identified. INTRODUCTION: Global posture deviations cause body adaptation and realignment, which may interfere with the organization and function of the temporomandibular joint. METHODS : Global posture evaluation was performed in a group of 10 female patients (20 to 30 years of age) with temporomandibular joint disc displacement and in a control group of 16 healthy female volunteers matched for age, weight and height. Anterior disc displacement signs, symptoms and the presence of parafunctional habits were also identified through interview. RESULTS: Patients with disc displacement showed a higher incidence of pain in the temporomandibular joint area, but there were no differences in parafunctional habits between the groups. In the disc displacement group, postural deviations were found in the pelvis (posterior rotation), lumbar spine (hyperlordosis), thoracic spine (rectification), head (deviation to the right) and mandibles (deviation to the left with open mouth). There were no differences in the longitudinal plantar arches between the groups. CONCLUSION: Our results suggest a close relationship between body posture and temporomandibular disorder, though it is not possible to determine whether postural deviations are the cause or the result of the disorder. Hence, postural evaluation could be an important component in the overall approach to providing accurate prevention and treatment in the management of patients with temporomandibular disorder. PMID:19142549
Mathematical simulation for compensation capacities area of pipeline routes in ship systems
NASA Astrophysics Data System (ADS)
Ngo, G. V.; Sakhno, K. N.
2018-05-01
In this paper, the authors considered the problem of manufacturability’s enhancement of ship systems pipeline at the designing stage. The analysis of arrangements and possibilities for compensation of deviations for pipeline routes has been carried out. The task was set to produce the “fit pipe” together with the rest of the pipes in the route. It was proposed to compensate for deviations by movement of the pipeline route during pipe installation and to calculate maximum values of these displacements in the analyzed path. Theoretical bases of deviation compensation for pipeline routes using rotations of parallel section pairs of pipes are assembled. Mathematical and graphical simulations of compensation area capacities of pipeline routes with various configurations are completed. Prerequisites have been created for creating an automated program that will allow one to determine values of the compensatory capacities area for pipeline routes and to assign quantities of necessary allowances.
Migration in the shearing sheet and estimates for young open cluster migration
NASA Astrophysics Data System (ADS)
Quillen, Alice C.; Nolting, Eric; Minchev, Ivan; De Silva, Gayandhi; Chiappini, Cristina
2018-04-01
Using tracer particles embedded in self-gravitating shearing sheet N-body simulations, we investigate the distance in guiding centre radius that stars or star clusters can migrate in a few orbital periods. The standard deviations of guiding centre distributions and maximum migration distances depend on the Toomre or critical wavelength and the contrast in mass surface density caused by spiral structure. Comparison between our simulations and estimated guiding radii for a few young supersolar metallicity open clusters, including NGC 6583, suggests that the contrast in mass surface density in the solar neighbourhood has standard deviation (in the surface density distribution) divided by mean of about 1/4 and larger than measured using COBE data by Drimmel and Spergel. Our estimate is consistent with a standard deviation of ˜0.07 dex in the metallicities measured from high-quality spectroscopic data for 38 young open clusters (<1 Gyr) with mean galactocentric radius 7-9 kpc.
Welding deviation detection algorithm based on extremum of molten pool image contour
NASA Astrophysics Data System (ADS)
Zou, Yong; Jiang, Lipei; Li, Yunhua; Xue, Long; Huang, Junfen; Huang, Jiqiang
2016-01-01
The welding deviation detection is the basis of robotic tracking welding, but the on-line real-time measurement of welding deviation is still not well solved by the existing methods. There is plenty of information in the gas metal arc welding(GMAW) molten pool images that is very important for the control of welding seam tracking. The physical meaning for the curvature extremum of molten pool contour is revealed by researching the molten pool images, that is, the deviation information points of welding wire center and the molten tip center are the maxima and the local maxima of the contour curvature, and the horizontal welding deviation is the position difference of these two extremum points. A new method of weld deviation detection is presented, including the process of preprocessing molten pool images, extracting and segmenting the contours, obtaining the contour extremum points, and calculating the welding deviation, etc. Extracting the contours is the premise, segmenting the contour lines is the foundation, and obtaining the contour extremum points is the key. The contour images can be extracted with the method of discrete dyadic wavelet transform, which is divided into two sub contours including welding wire and molten tip separately. The curvature value of each point of the two sub contour lines is calculated based on the approximate curvature formula of multi-points for plane curve, and the two points of the curvature extremum are the characteristics needed for the welding deviation calculation. The results of the tests and analyses show that the maximum error of the obtained on-line welding deviation is 2 pixels(0.16 mm), and the algorithm is stable enough to meet the requirements of the pipeline in real-time control at a speed of less than 500 mm/min. The method can be applied to the on-line automatic welding deviation detection.
NASA Astrophysics Data System (ADS)
Panda, S. K.; Gedam, S. S.; Rajaram, G.
2015-04-01
The present study investigates variation of the ionospheric total electron content (TEC) in the low latitude Indian sub-continental region from the GPS observations and its comparison with the global ionosphere maps (GIMs), standard international reference ionosphere (IRI 2012), and the standard plasmasphere-ionosphere model (SPIM) for the period from November 2011 to October 2012 that corresponds to the progressive phase towards the midst of the solar cycle-24. Observations during quiet period show diurnal maximum of TEC occurring around 14:00-16:00 IST, with relatively broader and longer duration of local maximum at Bangalore and behave reversely towards Delhi. The secondary maximum of TEC was markedly noticeable at Bangalore during the months of March and September, and only in the month of September at Hyderabad and Mumbai. However, the relatively higher TEC during December month than the June is ascribed to the winter anomaly which is more prevalent during the high solar activity periods. The prevailing instability in latitudes of anomaly crest during January 2012 is possibly due to the seasonal variation of lunar tidal effects, modulating the EEJ strength at the equator. The studies covered the period of a strong geomagnetic storm during 6-11 March 2012 (SYM-H: -149 nT) which resulted in positive deviation of GPS-TEC at Bangalore (↑ 20%), Hyderabad (↑ 22%), and Lucknow (↑ 94%) compared to the mean quiet days level. The relatively large deviation of TEC at Lucknow could be attributed to the poleward shifting of the anomaly crest, manifested by enhanced fountain effect at the equator. Studies confirm excellent agreement (80-85%) of GPS-TEC with IGS-GIM at Bangalore and Hyderabad with the exception of the night-time hours (Deviations >50%). However relatively larger deviation of GPS-TEC from GIM-TEC at Delhi could be due to the unavailability of IGS stations in the proximity of the position. Predictions of the SPIM model (extension of IRI up to GPS altitude) exhibit much higher deviation from the in situ GPS observations as well as GIM and IRI outputs during quiet periods. Correspondingly, either of the models (IRI and SPIM) did not respond well to the arrival of the sudden storm commencements (SSCs) during the storm period (6-11 March 2012). When SPIM is used instead of IRI, the overestimation from GPS-TECs are further exaggerated by 13-18% (December solstice), 27-37% (March equinox), 15-31% (June solstice), and 20-32% (September equinox) during peak hours of the period. We attribute the relatively more deviation of the SPIM than the IRI model possibly due to its plasmaspheric extension to the IRI model by adding the Russian SMI model of high latitude characteristics. Hence, we emphasize the further improvement in the model with due consideration of the driving forces at play in the region, for reliable predictions of the low latitude ionosphere.
Babb, James; Xia, Ding; Chang, Gregory; Krasnokutsky, Svetlana; Abramson, Steven B.; Jerschow, Alexej; Regatte, Ravinder R.
2013-01-01
Purpose: To assess the potential use of sodium magnetic resonance (MR) imaging of cartilage, with and without fluid suppression by using an adiabatic pulse, for classifying subjects with versus subjects without osteoarthritis at 7.0 T. Materials and Methods: The study was approved by the institutional review board and was compliant with HIPAA. The knee cartilage of 19 asymptomatic (control subjects) and 28 symptomatic (osteoarthritis patients) subjects underwent 7.0-T sodium MR imaging with use of two different sequences: one without fluid suppression (radial three-dimensional sequence) and one with fluid suppression (inversion recovery [IR] wideband uniform rate and smooth truncation [WURST]). Fluid suppression was obtained by using IR with an adiabatic inversion pulse (WURST pulse). Mean sodium concentrations and their standard deviations were measured in the patellar, femorotibial medial, and lateral cartilage regions over four consecutive sections for each subject. The minimum, maximum, median, and average means and standard deviations were calculated over all measurements for each subject. The utility of these measures in the detection of osteoarthritis was evaluated by using logistic regression and the area under the receiver operating characteristic curve (AUC). Bonferroni correction was applied to the P values obtained with logistic regression. Results: Measurements from IR WURST were found to be significant predicators of all osteoarthritis (Kellgren-Lawrence score of 1–4) and early osteoarthritis (Kellgren-Lawrence score of 1 or 2). The minimum standard deviation provided the highest AUC (0.83) with the highest accuracy (>78%), sensitivity (>82%), and specificity (>74%) for both all osteoarthritis and early osteoarthritis groups. Conclusion: Quantitative sodium MR imaging at 7.0 T with fluid suppression by using adiabatic IR is a potential biomarker for osteoarthritis. © RSNA, 2013 PMID:23468572
Modeling failure in brittle porous ceramics
NASA Astrophysics Data System (ADS)
Keles, Ozgur
Brittle porous materials (BPMs) are used for battery, fuel cell, catalyst, membrane, filter, bone graft, and pharmacy applications due to the multi-functionality of their underlying porosity. However, in spite of its technological benefits the effects of porosity on BPM fracture strength and Weibull statistics are not fully understood--limiting a wider use. In this context, classical fracture mechanics was combined with two-dimensional finite element simulations not only to account for pore-pore stress interactions, but also to numerically quantify the relationship between the local pore volume fraction and fracture statistics. Simulations show that even the microstructures with the same porosity level and size of pores differ substantially in fracture strength. The maximum reliability of BPMs was shown to be limited by the underlying pore--pore interactions. Fracture strength of BMPs decreases at a faster rate under biaxial loading than under uniaxial loading. Three different types of deviation from classic Weibull behavior are identified: P-type corresponding to a positive lower tail deviation, N-type corresponding to a negative lower tail deviation, and S-type corresponding to both positive upper and lower tail deviations. Pore-pore interactions result in either P-type or N-type deviation in the limit of low porosity, whereas S-type behavior occurs when clusters of low and high fracture strengths coexist in a fracture data.
Yalçınkaya, Esin; Cingi, Cemal; Bayar Muluk, Nuray; Ulusoy, Seçkin; Hanci, Deniz
2016-01-01
Numerous factors can be considered for the etiology of temporomandibular disorders (TMD). The aim of the present study was to investigate whether the presence of both nasal septal deviation (NSD) and habitual prone sleeping posture (HPSP) predisposes TMD. We evaluated 200 subjects in 4 groups. Group I (NSD-, HPSP-/control group), Group II (NSD+, HPSP-), Group III (NSD-, HPSP+), Group IV (NSD+, HPSP+). All patients were examined according to the research diagnostic criteria to determine the presence of TMD. Group IV had the highest value for TMD incidence (44 %). Thus, we found that the presence of both NSD and HPSP parameters increased TMD incidence in Group IV compared to the control group (p = 0.000). Additionally, Group IV showed significantly higher values than Group II (p = 0.012) and Group III (p = 0.039). For Group III (NSD-, HPSP+), TMD was determined higher compared to the control group (p = 0.009). A statistically higher value of presence of TMD was determined in Group II (NSD+, HPSP-) than control group (p = 0.029). The incidence of TMD was significantly higher in women than men (p = 0.020). We concluded that one having an unilateral obstructive nasal septal deviation in addition to a habit of sleeping in prone position must be alert for potential TMD.
Aswehlee, Amel M; Hattori, Mariko; Elbashti, Mahmoud E; Sumita, Yuka I; Taniguchi, Hisashi
This study aimed (1) to geometrically evaluate areas of facial asymmetry in patients with two different types of maxillectomy defect compared to a control group, (2) to geometrically evaluate the effect of an obturator prosthesis on facial asymmetry, and (3) to investigate the correlation between three-dimensional (3D) deviation values and number of missing teeth. Facial data from 13 normal control participants and 26 participants with two types of maxillectomy defect (groups 1 and 2) were acquired with a noncontact 3D digitizer. Facial asymmetry was evaluated by superimposing a facial scan onto its mirror scan using 3D evaluation software. Facial scans with and without obturator prostheses were also superimposed to evaluate the obturator effect. The correlation between 3D deviation values and number of missing teeth was also evaluated. Statistical analyses were performed. Facial asymmetry was significantly different between the control group and each maxillectomy defect group (group 1: P < .0001 and P = .020 without and with obturator, respectively; group 2: P < .0001 for both conditions). There were no significant differences in asymmetry between groups 1 and 2 either without or with obturator (P = .457 and P = .980, respectively). There was a significant difference in the obturator effect between groups 1 and 2 (P = .038). 3D deviation values were positively correlated with number of missing teeth in group 1 (r = 0.594, P = .032), but not in group 2. A noncontact 3D digitizer and 3D deviation assessment were effective for analyzing facial data of maxillectomy patients. Obturators were effective for improving facial deformities in these patients.
Sex ratio of congenital abnormalities in the function of maternal age: a population-based study.
Csermely, Gyula; Urbán, Robert; Czeizel, Andrew E; Veszprémi, Béla
2015-05-01
Maternal age effect is well-known in the origin of numerical chromosomal aberrations and some isolated congenital abnormalities (CAs). The sex ratio (SR), i.e. number of males divided by the number of males and females together, of most CAs deviates from the SR of newborn population (0.51). The objective of this analysis was to evaluate the possible association of maternal age with the SR of isolated CAs in a population-based large dataset of the Hungarian Case-Control Surveillance of Congenital Abnormalities, 1980-1996. First, SR of 24 CA entities/groups was estimated in 21,494 patients with isolated CA. In the next step SR of different maternal age groups was compared to the mean SR of the given CA-groups. The SR of four CA-groups showed some deviation in certain maternal age groups. Cases with anencephaly had female excess in young mothers (<25 years). Cases with skull's CAs particularly craniosynostosis had a male excess in cases born to women over 30 years. Two other CA groups (cleft lip ± palate and valvar pulmonic stenosis within the group of right-sided obstructive defect of heart) had significant deviation in SR of certain maternal age groups from the mean SR, but these deviations were not harmonized with joining age groups and thus were considered as a chance effect due to multiple testing. In conclusion, our study did not suggest that in general SR of isolated CAs might be modified by certain maternal age groups with some exception such as anencephaly and craniosynostosis. © 2014 Japanese Teratology Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levegruen, Sabine, E-mail: sabine.levegruen@uni-due.de; Poettgen, Christoph; Abu Jawad, Jehad
Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determinedmore » at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.« less
Levegrün, Sabine; Pöttgen, Christoph; Jawad, Jehad Abu; Berkovic, Katharina; Hepp, Rodrigo; Stuschke, Martin
2013-02-01
To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after ≥4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed. Copyright © 2013 Elsevier Inc. All rights reserved.
Band-aid for information loss from black holes
NASA Astrophysics Data System (ADS)
Israel, Werner; Yun, Zinkoo
2010-12-01
We summarize, simplify and extend recent work showing that small deviations from exact thermality in Hawking radiation, first uncovered by Kraus and Wilczek, have the capacity to carry off the maximum information content of a black hole. This goes a considerable way toward resolving a long-standing “information loss paradox.”
Reversible solid oxide fuel cell for natural gas/renewable hybrid power generation systems
NASA Astrophysics Data System (ADS)
Luo, Yu; Shi, Yixiang; Zheng, Yi; Cai, Ningsheng
2017-02-01
Renewable energy (RE) is expected to be the major part of the future energy. Presently, the intermittence and fluctuation of RE lead to the limitation of its penetration. Reversible solid oxide fuel cell (RSOFC) as the energy storage device can effectively store the renewable energy and build a bidirectional connection with natural gas (NG). In this paper, the energy storage strategy was designed to improve the RE penetration and dynamic operation stability in a distributed system coupling wind generators, internal combustion engine, RSOFC and lithium-ion batteries. By compromising the relative deviation of power supply and demand, RE penetration, system efficiency and capacity requirement, the strategy that no more than 36% of the maximum wind power output is directly supplied to users and the other is stored by the combination of battery and reversible solid oxide fuel cell is optimal for the distributed system. In the case, the RE penetration reached 56.9% and the system efficiency reached 55.2%. The maximum relative deviation of power supply and demand is also lower than 4%, which is significantly superior to that in the wind curtailment case.
Fabrication of setup for high temperature thermal conductivity measurement.
Patel, Ashutosh; Pandey, Sudhir K
2017-01-01
In this work, we report the fabrication of an experimental setup for high temperature thermal conductivity (κ) measurement. It can characterize samples with various dimensions and shapes. Steady state based axial heat flow technique is used for κ measurement. Heat loss is measured using parallel thermal conductance technique. Simple design, lightweight, and small size sample holder is developed by using a thin heater and limited components. Low heat loss value is achieved by using very low thermal conductive insulator block with small cross-sectional area. Power delivered to the heater is measured accurately by using 4-wire technique and for this, the heater is developed with 4 wires. This setup is validated by using Bi 0.36 Sb 1.45 Te 3 , polycrystalline bismuth, gadolinium, and alumina samples. The data obtained for these samples are found to be in good agreement with the reported data. The maximum deviation of 6% in the value κ is observed. This maximum deviation is observed with the gadolinium sample. We also report the thermal conductivity of polycrystalline tellurium from 320 K to 550 K and the nonmonotonous behavior of κ with temperature is observed.
Expected distributions of root-mean-square positional deviations in proteins.
Pitera, Jed W
2014-06-19
The atom positional root-mean-square deviation (RMSD) is a standard tool for comparing the similarity of two molecular structures. It is used to characterize the quality of biomolecular simulations, to cluster conformations, and as a reaction coordinate for conformational changes. This work presents an approximate analytic form for the expected distribution of RMSD values for a protein or polymer fluctuating about a stable native structure. The mean and maximum of the expected distribution are independent of chain length for long chains and linearly proportional to the average atom positional root-mean-square fluctuations (RMSF). To approximate the RMSD distribution for random-coil or unfolded ensembles, numerical distributions of RMSD were generated for ensembles of self-avoiding and non-self-avoiding random walks. In both cases, for all reference structures tested for chains more than three monomers long, the distributions have a maximum distant from the origin with a power-law dependence on chain length. The purely entropic nature of this result implies that care must be taken when interpreting stable high-RMSD regions of the free-energy landscape as "intermediates" or well-defined stable states.
Long-term changes (1980-2003) in total ozone time series over Northern Hemisphere midlatitudes
NASA Astrophysics Data System (ADS)
Białek, Małgorzata
2006-03-01
Long-term changes in total ozone time series for Arosa, Belsk, Boulder and Sapporo stations are examined. For each station we analyze time series of the following statistical characteristics of the distribution of daily ozone data: seasonal mean, standard deviation, maximum and minimum of total daily ozone values for all seasons. The iterative statistical model is proposed to estimate trends and long-term changes in the statistical distribution of the daily total ozone data. The trends are calculated for the period 1980-2003. We observe lessening of negative trends in the seasonal means as compared to those calculated by WMO for 1980-2000. We discuss a possibility of a change of the distribution shape of ozone daily data using the Kolmogorov-Smirnov test and comparing trend values in the seasonal mean, standard deviation, maximum and minimum time series for the selected stations and seasons. The distribution shift toward lower values without a change in the distribution shape is suggested with the following exceptions: the spreading of the distribution toward lower values for Belsk during winter and no decisive result for Sapporo and Boulder in summer.
Trajectory Optimization of Electric Aircraft Subject to Subsystem Thermal Constraints
NASA Technical Reports Server (NTRS)
Falck, Robert D.; Chin, Jeffrey C.; Schnulo, Sydney L.; Burt, Jonathan M.; Gray, Justin S.
2017-01-01
Electric aircraft pose a unique design challenge in that they lack a simple way to reject waste heat from the power train. While conventional aircraft reject most of their excess heat in the exhaust stream, for electric aircraft this is not an option. To examine the implications of this challenge on electric aircraft design and performance, we developed a model of the electric subsystems for the NASA X-57 electric testbed aircraft. We then coupled this model with a model of simple 2D aircraft dynamics and used a Legendre-Gauss-Lobatto collocation optimal control approach to find optimal trajectories for the aircraft with and without thermal constraints. The results show that the X-57 heat rejection systems are well designed for maximum-range and maximum-efficiency flight, without the need to deviate from an optimal trajectory. Stressing the thermal constraints by reducing the cooling capacity or requiring faster flight has a minimal impact on performance, as the trajectory optimization technique is able to find flight paths which honor the thermal constraints with relatively minor deviations from the nominal optimal trajectory.
Implementation of small field radiotherapy dosimetry for spinal metastase case
NASA Astrophysics Data System (ADS)
Rofikoh, Wibowo, W. E.; Pawiro, S. A.
2017-07-01
The main objective of this study was to know dose profile of small field radiotherapy in the spinal metastase case with source axis distance (SAD) techniques. In addition, we evaluated and compared the dose planning of stereotactic body radiation therapy (SBRT) and conventional techniques to measurements with Exradin A16 and Gafchromic EBT3 film dosimeters. The results showed that film EBT3 had a highest precision and accuracy with the average of the standard deviation of ±1.7 and maximum discrepancy of 2.6 %. In addition, the average value of Full Wave Half Maximum (FWHM) and its largest deviation in small field size of 0.8 x 0.8 cm2 are 0.82 cm and 16.3 % respectively, while it was found around 2.36 cm and 3 % for the field size of 2.4 x 2.4 cm2. The comparison between penumbra width and the collimation was around of 37.1 % for the field size of 0.8 x 0.8 cm2, while it was found of 12.4 % for the field size of 2.4 x 2.4 cm2.
Effects of Intraosseous Tibial vs. Intravenous Vasopressin in a Hypovolemic Cardiac Arrest Model
Fulkerson, Justin; Lowe, Robert; Anderson, Tristan; Moore, Heather; Craig, William; Johnson, Don
2016-01-01
Introduction This study compared the effects of vasopressin via tibial intraosseous (IO) and intravenous (IV) routes on maximum plasma concentration (Cmax), the time to maximum concentration (Tmax), return of spontaneous circulation (ROSC), and time to ROSC in a hypovolemic cardiac arrest model. Methods This study was a randomized prospective, between-subjects experimental design. A computer program randomly assigned 28 Yorkshire swine to one of four groups: IV (n=7), IO tibia (n=7), cardiopulmonary resuscitation (CPR) + defibrillation (n=7), and a control group that received just CPR (n=7). Ventricular fibrillation was induced, and subjects remained in arrest for two minutes. CPR was initiated and 40 units of vasopressin were administered via IO or IV routes. Blood samples were collected at 0.5, 1, 1.5, 2, 2.5, 3, and 4 minutes. CPR and defibrillation were initiated for 20 minutes or until ROSC was achieved. We measured vasopressin concentrations using high-performance liquid chromatography. Results There was no significant difference between the IO and IV groups relative to achieving ROSC (p=1.0) but a significant difference between the IV compared to the CPR+ defibrillation group (p=0.031) and IV compared to the CPR-only group (p=0.001). There was a significant difference between the IO group compared to the CPR+ defibrillation group (p=0.031) and IO compared to the CPR-only group (p=0.001). There was no significant difference between the CPR + defibrillation group and the CPR group (p=0.127). There was no significant difference in Cmax between the IO and IV groups (p=0.079). The mean ± standard deviation of Cmax of the IO group was 58,709±25, 463pg/mL compared to the IV group, which was 106,198±62, 135pg/mL. There was no significant difference in mean Tmax between the groups (p=0.084). There were no significant differences in odds of ROSC between the tibial IO and IV groups. Conclusion Prompt access to the vascular system using the IO route can circumvent the interruption in treatment observed with attempting conventional IV access. The IO route is an effective modality for the treatment of hypovolemic cardiac arrest and may be considered first line for rapid vascular access. PMID:26973756
Effects of Intraosseous Tibial vs. Intravenous Vasopressin in a Hypovolemic Cardiac Arrest Model.
Fulkerson, Justin; Lowe, Robert; Anderson, Tristan; Moore, Heather; Craig, William; Johnson, Don
2016-03-01
This study compared the effects of vasopressin via tibial intraosseous (IO) and intravenous (IV) routes on maximum plasma concentration (Cmax), the time to maximum concentration (Tmax), return of spontaneous circulation (ROSC), and time to ROSC in a hypovolemic cardiac arrest model. This study was a randomized prospective, between-subjects experimental design. A computer program randomly assigned 28 Yorkshire swine to one of four groups: IV (n=7), IO tibia (n=7), cardiopulmonary resuscitation (CPR) + defibrillation (n=7), and a control group that received just CPR (n=7). Ventricular fibrillation was induced, and subjects remained in arrest for two minutes. CPR was initiated and 40 units of vasopressin were administered via IO or IV routes. Blood samples were collected at 0.5, 1, 1.5, 2, 2.5, 3, and 4 minutes. CPR and defibrillation were initiated for 20 minutes or until ROSC was achieved. We measured vasopressin concentrations using high-performance liquid chromatography. There was no significant difference between the IO and IV groups relative to achieving ROSC (p=1.0) but a significant difference between the IV compared to the CPR+ defibrillation group (p=0.031) and IV compared to the CPR-only group (p=0.001). There was a significant difference between the IO group compared to the CPR+ defibrillation group (p=0.031) and IO compared to the CPR-only group (p=0.001). There was no significant difference between the CPR + defibrillation group and the CPR group (p=0.127). There was no significant difference in Cmax between the IO and IV groups (p=0.079). The mean ± standard deviation of Cmax of the IO group was 58,709±25, 463 pg/mL compared to the IV group, which was 106,198±62, 135 pg/mL. There was no significant difference in mean Tmax between the groups (p=0.084). There were no significant differences in odds of ROSC between the tibial IO and IV groups. Prompt access to the vascular system using the IO route can circumvent the interruption in treatment observed with attempting conventional IV access. The IO route is an effective modality for the treatment of hypovolemic cardiac arrest and may be considered first line for rapid vascular access.
The turbulence structure of katabatic flows below and above wind-speed maximum
NASA Astrophysics Data System (ADS)
Grachev, Andrey; Leo, Laura; Di Sabatino, Silvana; Fernando, Harindra; Pardyjak, Eric; Fairall, Christopher
2015-04-01
Measurements of atmospheric small-scale turbulence made over the complex-terrain at the US Army Dugway Proving Grounds in Utah during the Mountain Terrain Atmospheric Modeling and Observations (MATERHORN) Program are used to describe the turbulence structure of katabatic flows. Turbulent and mean meteorological data were continuously measured at multiple levels (up to seven) on four towers deployed along East lower slope (2-4 degrees) of Granite Mountain. The multi-level, multi-tower observations obtained during a 30-day long MATERHORN-Fall field campaign in September-October 2102 allow studying temporal and spatial structure of nocturnal slope flows in detail. In this study, we focus on the various statistics (fluxes, variances, spectra, cospectra, etc.) of the small-scale turbulence of katabatic winds. Observed vertical profiles of velocity, turbulent fluxes, and other quantities show steep gradients near the surface but in the layer above the slope jet these variables vary with height more slowly than near the surface. It is found that vertical momentum flux and horizontal heat (buoyancy) flux in a slope-following coordinate system change their sign below and above the wind maximum of a katabatic flow. The vertical momentum flux is directed downward (upward) whereas the horizontal heat flux is downslope (upslope) below (above) the wind maximum. Our study, therefore, suggests that a position of the jet speed maximum can be derived from linear interpolation between positive and negative values of the momentum flux (or the horizontal heat flux) and determination of a height where a flux becomes zero. It is shown that the standard deviations of all wind speed components (and therefore the turbulent kinetic energy) and the dissipation rate of turbulent kinetic energy have a local minimum, whereas the standard deviation of air temperature has an absolute maximum at the height of wind speed maximum. We report several cases when the destructive effect of vertical heat (buoyancy) flux is completely cancelled by the generation of turbulence due to the horizontal heat (buoyancy) flux. Turbulence in the layer above the wind-speed maximum is decoupled from the surface and it is consistent with the classical local z-less predictions for stably stratified boundary layer.
Measured drift of irradiated and unirradiated W3%Re/W25%Re thermocouples at a nominal 2000 K.
NASA Technical Reports Server (NTRS)
Heckelman, J. D.; Kozar, R. P.
1972-01-01
Seven tantalum sheathed, BeO insulated, 0.157-cm-diam, grounded-junction W-3%Re/W-25%Re thermocouples were irradiated in a helium-argon environment at a temperature of 1900 to 2100 K. Six other thermocouples from the same lot were operated out-of-pile with the same temperature history as the in-pile thermocouples. Drift-in-pile was determined by periodically replacing a 'reference' thermocouple in the irradiation capsule. Drift out-of-pile was determined with an optical pyrometer. After 8000 hours irradiation, the estimated neutron fluence was 4 x 10 to the 21st power thermal neutrons/sq cm and 0.9 x 10 to the 21st power fast neutrons/sq cm (E greater than 0.18 MeV). At this time the in-pile group had decreased in output the equivalent of 340 K at 2073 K, while the out-of-pile group had decreased in output the equivalent of 54 K at 2073 K. The maximum deviation in drift between thermocouples of the in-pile group and between thermocouples of the out-of-pile group was less than plus or minus 15 K and less than plus or minus 10 K, respectively.
Ballanti, Fabiana; Baldini, Alberto; Ranieri, Salvatore; Nota, Alessandro; Cozza, Paola
2016-04-01
Deviated nasal septum may cause a reduction of the nasal airflow, thus, during the craniofacial development, a reduced nasal airflow could originate a chronic mouth-breathing pattern, related with moderate to severe maxillary constriction. The aim of this retrospective study is to analyze the correlation between maxillary transverse deficiency and nasal septum deviation. Frontal cephalograms were performed on 66 posterior-anterior radiographs of subjects (34M, 32F; mean age 9.95±2.50 years) with maxillary transverse deficiency and on a control group of 31 posterior-anterior radiographs of subjects (13M, 18F; 9.29±2.08 years). Angular parameters of the nasal cavities were recorded and compared between the two groups using a Student's t-test. Generally all the parameters are very similar between the two groups except for the ASY angle that differs for about the 27%; anyway the Student's t-test showed no statistically significant differences between the two groups (mostly p>0.20). This study failed to show an association between transverse maxillary deficiencies and nasal septum deviations. Moreover, no significant differences were found between the mean nasal cavities dimensions in subjects with transverse maxillary deficiency and the control group. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Neurological development of children born to mothers after kidney transplantation.
Schreiber-Zamora, Joanna; Szpotanska-Sikorska, Monika; Drozdowska-Szymczak, Agnieszka; Czaplinska, Natalia; Pietrzak, Bronisława; Wielgos, Miroslaw; Kociszewska-Najman, Bozena
2017-12-03
Pregnancies after kidney transplantation are at high risk of complications such as preterm birth and foetal growth restriction. Until now, the impact of these factors on neurological development of children born to transplant mothers has not been established. A comparison of neurological examinations performed in 36 children of kidney transplant women (study group) and 36 children born to healthy mothers (control group). The children from both groups were born at a similar gestational age and in the similar time period from 12/1996 to 09/2012. Neurological examinations were performed from 07/2010 to 11/2013. Each examination was adjusted to the patient's age and performed after the neonatal period. Three years later children were re-consulted, if they presented neurological deviations or were less than 12 months old at the time of the first examination. Normal neurological development was found in 86% of children in both groups (p = .999). Mild neurological deviations were observed in four (11%) children born to kidney transplant mothers and in five (14%) children born to healthy mothers (p = .999). Moderate deviations were diagnosed in one premature child born to transplant mother, whose pregnancy was complicated with a severe preeclampsia and foetal growth restriction. In the study population, no severe neurological disorders were found. Almost all (8/10) children with neurological deviations were born prematurely in good general conditions. The neurological deviations observed in the first year of life were mild and transient. In children over 1 year of age, deviations were more pronounced and continued to maintain. The neurological development of children of kidney transplant women is similar to that of the general population and possible deviations seem to be the result of intrauterine hypotrophy and prematurity. Therefore, in clinical practice, it is necessary to plan post-transplant pregnancies especially in women at high risk of these complications.
Han, Sangyoun; Jung, Jong Jin; Kim, Ungsoo Samuel
2015-12-01
To investigate the differences in retinal nerve fiber layer (RNFL) change and optic nerve head parameters between non-arteritic anterior ischemic optic neuropathy (NAION) and open angle glaucoma (OAG) with altitudinal visual field defect. Seventeen NAION patients and 26 OAG patients were enrolled prospectively. The standard visual field indices (mean deviation, pattern standard deviation) were obtained from the Humphrey visual field test and differences between the two groups were analyzed. Cirrus HD-OCT parameters were used, including optic disc head analysis, average RNFL thickness, and RNFL thickness of each quadrant. The mean deviation and pattern standard deviation were not significantly different between the groups. In the affected eye, although the disc area was similar between the two groups (2.00 ± 0.32 and 1.99 ± 0.33 mm(2), p = 0.586), the rim area of the OAG group was smaller than that of the NAION group (1.26 ± 0.56 and 0.61 ± 0.15 mm(2), respectively, p < 0.001). RNFL asymmetry was not different between the two groups (p = 0.265), but the inferior RNFL thickness of both the affected and unaffected eyes were less in the OAG group than in the NAION group. In the analysis of optic disc morphology, both affected and unaffected eyes showed significant differences between two groups. To differentiate NAION from OAG in eyes with altitudinal visual field defects, optic disc head analysis of not only the affected eye, but also the unaffected eye, by using spectral domain optical coherence tomography may be helpful.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X; Studenski, M; Yang, F
Purpose: MRI-guided-radiotherapy (MRIGRT) systems lack many features of traditional Linac based RT systems and specialized tests need to be developed to evaluate MLC performance. This work describes automatic tools for the analysis of positional accuracy of an MLC equipped MRIGRT system. Methods: This MLC analysis tool was developed for the MRIdian™ RT system which has three Co-60 equipped treatment heads each with a double focused MLC containing 30 leaf pairs, leaf thickness is 1.05cm defined at isocenter (SAD 105 cm). For MLC positional analysis a picket fence test was performed using a 25.4cm × 25.4cm Gafchromic™ RTQA2 film placed betweenmore » 5cm solidwater and a 30cm × 30cm × 1cm jigwire phantom with seven embedded parallel metal strips 4cm apart. A plan was generated to deliver 2Gy per field and seven 23.1cm × 2cm fields centered over each wire in the phantom. For each leaf pair the center of the radiation profile was determined by fitting the horizontal profile with a Gaussian model and determining the center of the FWHM. This was compared with the metal strip location to determine any deviation. The following metrics were used to evaluate the deviations per gantry angle including maximum, minimum, mean, Kurtosis, and skewness. Results: The identified maximum/mean leaf deviations are, 1.32/0.55 mm for gantry 0°, 1.59/0.76 mm for gantry 90°, and 1.19/0.39 mm for gantry 270°. The percentage of leaf deviation less than 1mm are 90.0% at 0°, 74.6% at 90°, and 97.0% at 270°. Kurtosis/skewness of the leaf deviation are 2.41/0.14 at 0°, 2.53/0.23 at 90°, 3.33/0.83 at 270°, respectively. Conclusion: This work presents an automatic tool for evaluation of the MLC position accuracy of the MRIdian™ radiotherapy system which can be used to benchmark the performance of the MLC system for each treatment head and track the results longitudinally.« less
Large-size space debris flyby in low earth orbits
NASA Astrophysics Data System (ADS)
Baranov, A. A.; Grishko, D. A.; Razoumny, Y. N.
2017-09-01
the analysis of NORAD catalogue of space objects executed with respect to the overall sizes of upper-stages and last stages of carrier rockets allows the classification of 5 groups of large-size space debris (LSSD). These groups are defined according to the proximity of orbital inclinations of the involved objects. The orbits within a group have various values of deviations in the Right Ascension of the Ascending Node (RAAN). It is proposed to use the RAANs deviations' evolution portrait to clarify the orbital planes' relative spatial distribution in a group so that the RAAN deviations should be calculated with respect to the concrete precessing orbital plane of the concrete object. In case of the first three groups (inclinations i = 71°, i = 74°, i = 81°) the straight lines of the RAAN relative deviations almost do not intersect each other. So the simple, successive flyby of group's elements is effective, but the significant value of total Δ V is required to form drift orbits. In case of the fifth group (Sun-synchronous orbits) these straight lines chaotically intersect each other for many times due to the noticeable differences in values of semi-major axes and orbital inclinations. The intersections' existence makes it possible to create such a flyby sequence for LSSD group when the orbit of one LSSD object simultaneously serves as the drift orbit to attain another LSSD object. This flyby scheme requiring less Δ V was called "diagonal." The RAANs deviations' evolution portrait built for the fourth group (to be studied in the paper) contains both types of lines, so the simultaneous combination of diagonal and successive flyby schemes is possible. The value of total Δ V and temporal costs were calculated to cover all the elements of the 4th group. The article is also enriched by the results obtained for the flyby problem solution in case of all the five mentioned LSSD groups. The general recommendations are given concerned with the required reserve of total Δ V and with amount of detachable de-orbiting units onboard the maneuvering platform and onboard the refueling vehicle.
Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser
2013-01-01
The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for vertical positioning between groups B and R. The P-value for rotational positioning between groups A and B and between groups A and R was <.001. No significant differences were found for rotational positioning between groups B and R. The results of the study confirmed that implant systems differ in precision of fit. Vertical precision between paired implant components is a function of joint type and the tightening force applied to the guide pin. The magnitude of vertical displacement with applied torque is greater for conical connections than for butt joint connections. The rotational freedom between paired components is unique to the implant system and is presumably related to the machining tolerances specified by the manufacturer. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Quality assurance of proton beams using a multilayer ionization chamber system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhanesar, Sandeep; Sahoo, Narayan; Kerr, Matthew
2013-09-15
Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used tomore » measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements.Conclusions: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.« less
4,4′-[Ethylenebis(nitrilomethylidyne)]dibenzonitrile
Kia, Reza; Fun, Hoong-Kun; Kargar, Hadi
2009-01-01
The molecule of the title Schiff base compound, C18H14N4, lies across a crystallographic inversion centre and adopts an E configuration with respect to the azomethine (C=N) bonds. The imino groups are coplanar with the aromatic rings with a maximum deviation of 0.1574 (12) Å for the N atom. Within the molecule, the planar units are parallel, but extend in opposite directions from the dimethylene bridge. In the crystal structure, pairs of intermolecular C—H⋯N hydrogen bonds link neighbouring molecules into centrosymmetric dimers with R 2 2(10) ring motifs. An interesting feature of the crystal structure is the short intermolecular C⋯C interaction with a distance of 3.3821 (13) Å, which is shorter than the sum of the van der Waals radius of a carbon atom. PMID:21582425
Özek Yıldırım, Arzu; Gülsu, Murat; Albayrak Kaştaş, Çiğdem
2018-03-01
The title compound, C 16 H 16 BrNO 3 , which shows enol-imine tautomerism, crystallizes in the monoclinic P 2 1 / c space group. All non-H atoms of the mol-ecule are nearly coplanar, with a maximum deviation of 0.274 (3) Å. In the crystal, mol-ecules are held together by weak C-H⋯O, π-π and C-H⋯π inter-actions. The E / Z isomerism and enol/keto tautomerism energy barriers of the compound have been calculated by relaxed potential energy surface scan calculations with DFT methods. To observe the changes in the aromatic ring, HOMA aromaticity indexes were calculated during the scan process. Total energy and HOMA change curves were obtained to visualize results of the scan calculations.
N-(2-Allyl-4-chloro-2H-indazol-5-yl)-4-methoxybenzenesulfonamide hemihydrate
Chicha, Hakima; Kouakou, Assoman; Rakib, El Mostapha; Saadi, Mohamed; El Ammari, Lahcen
2013-01-01
The fused five- and six-membered rings in the title compound, C17H16ClN3O3S·0.5H2O, are practically coplanar, with the maximum deviation from the mean plane being 0.057 (3) Å for the C atom bound to the exocyclic N atom. The indazole system makes a dihedral angle of 66.18 (12)° with the plane through the benzene ring, and it is nearly perpendicular to the allyl group, as indicated by the N—N—C—C torsion angle of 79.2 (3)°. In the crystal, the water molecule, lying on a twofold axis, forms O—H⋯N and accepts N—H⋯O hydrogen bonds. Additional C—H⋯O hydrogen bonds contribute to the formation of a chain along the b-axis direction. PMID:24109418
N-(2-Allyl-4-chloro-2H-indazol-5-yl)-4-meth-oxy-benzene-sulfonamide hemi-hydrate.
Chicha, Hakima; Kouakou, Assoman; Rakib, El Mostapha; Saadi, Mohamed; El Ammari, Lahcen
2013-01-01
The fused five- and six-membered rings in the title compound, C17H16ClN3O3S·0.5H2O, are practically coplanar, with the maximum deviation from the mean plane being 0.057 (3) Å for the C atom bound to the exocyclic N atom. The indazole system makes a dihedral angle of 66.18 (12)° with the plane through the benzene ring, and it is nearly perpendicular to the allyl group, as indicated by the N-N-C-C torsion angle of 79.2 (3)°. In the crystal, the water mol-ecule, lying on a twofold axis, forms O-H⋯N and accepts N-H⋯O hydrogen bonds. Additional C-H⋯O hydrogen bonds contribute to the formation of a chain along the b-axis direction.
Vercruyssen, M; Coucke, W; Naert, I; Jacobs, R; Teughels, W; Quirynen, M
2015-11-01
To assess the accuracy of guided surgery compared with mental navigation or the use of a pilot-drill template in fully edentulous patients. Sixty consecutive patients (72 jaws), requiring four to six implants (maxilla or mandible), were randomly assigned to one of the following treatment modalities: Materialise Universal(®) mucosa, Materialise Universal(®) bone, Facilitate(™) mucosa, Facilitate(™) bone, mental navigation, or a pilot-drill template. Accuracy was assessed by matching the planning CT with a postoperative CBCT. Deviations were registered in a vertical (depth) and horizontal (lateral) plane. The latter further subdivided into BL (bucco-lingual) and MD (mesio-distal) deviations. The overall mean vertical deviation for the guided surgery groups was 0.9 mm ± 0.8 (range: 0.0-3.7) and 0.9 mm ± 0.6 (range: 0.0-2.9) in a horizontal direction. For the non-guided groups, this was 1.7 mm ± 1.3 (range: 0.0-6.4) and 2.1 mm ± 1.4 (range 0.0-8.5), respectively (P < 0.05). The overall mean deviation for the guided surgery groups in MD direction was 0.6 mm ± 0.5 (range: 0.0-2.5) and 0.5 mm ± 0.5 (range: 0.0-2.9) in BL direction. For the non-guided groups, this was 1.8 mm ± 1.4 (range: 0.0-8.3) and 0.7 mm ± 0.6 (range 0.0-2.9), respectively. The deviation in MD direction was significantly higher in the non-guided groups (P = 0.0002). The most important inaccuracy with guided surgery is in vertical direction (depth). The inaccuracy in MD or BL direction is clearly less. For non-guided surgery, the inaccuracy is significantly higher. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Network-Cognizant Design of Decentralized Volt/VAR Controllers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, Kyri A; Bernstein, Andrey; Zhao, Changhong
This paper considers the problem of designing decentralized Volt/VAR controllers for distributed energy resources (DERs). The voltage-reactive power characteristics of individual DERs are obtained by solving a convex optimization problem, where given performance objectives (e.g., minimization of the voltage deviations from a given profile) are specified and stability constraints are enforced. The resultant Volt/VAR characteristics are network-cognizant, in the sense that they embed information on the location of the DERs and, consequently, on the effect of reactive-power adjustments on the voltages throughout the feeder. Bounds on the maximum voltage deviation incurred by the controllers are analytically established. Numerical results aremore » reported to corroborate the technical findings.« less
Abuasbi, Falastine; Lahham, Adnan; Abdel-Raziq, Issam Rashid
2018-04-01
This study was focused on the measurement of residential exposure to power frequency (50-Hz) electric and magnetic fields in the city of Ramallah-Palestine. A group of 32 semi-randomly selected residences distributed amongst the city were under investigations of fields variations. Measurements were performed with the Spectrum Analyzer NF-5035 and were carried out at one meter above ground level in the residence's bedroom or living room under both zero and normal-power conditions. Fields' variations were recorded over 6-min and some times over few hours. Electric fields under normal-power use were relatively low; ~59% of residences experienced mean electric fields <10 V/m. The highest mean electric field of 66.9 V/m was found at residence R27. However, electric field values were log-normally distributed with geometric mean and geometric standard deviation of 9.6 and 3.5 V/m, respectively. Background electric fields measured under zero-power use, were very low; ~80% of residences experienced background electric fields <1 V/m. Under normal-power use, the highest mean magnetic field (0.45 μT) was found at residence R26 where an indoor power substation exists. However, ~81% of residences experienced mean magnetic fields <0.1 μT. Magnetic fields measured inside the 32 residences showed also a log-normal distribution with geometric mean and geometric standard deviation of 0.04 and 3.14 μT, respectively. Under zero-power conditions, ~7% of residences experienced average background magnetic field >0.1 μT. Fields from appliances showed a maximum mean electric field of 67.4 V/m from hair dryer, and maximum mean magnetic field of 13.7 μT from microwave oven. However, no single result surpassed the ICNIRP limits for general public exposures to ELF fields, but still, the interval 0.3-0.4 μT for possible non-thermal health impacts of exposure to ELF magnetic fields, was experienced in 13% of the residences.
NASA Astrophysics Data System (ADS)
Li, Yongming; Li, Fan; Wang, Pin; Zhu, Xueru; Liu, Shujun; Qiu, Mingguo; Zhang, Jingna; Zeng, Xiaoping
2016-10-01
Traditional age estimation methods are based on the same idea that uses the real age as the training label. However, these methods ignore that there is a deviation between the real age and the brain age due to accelerated brain aging. This paper considers this deviation and searches for it by maximizing the separability distance value rather than by minimizing the difference between the estimated brain age and the real age. Firstly, set the search range of the deviation as the deviation candidates according to prior knowledge. Secondly, use the support vector regression (SVR) as the age estimation model to minimize the difference between the estimated age and the real age plus deviation rather than the real age itself. Thirdly, design the fitness function based on the separability distance criterion. Fourthly, conduct age estimation on the validation dataset using the trained age estimation model, put the estimated age into the fitness function, and obtain the fitness value of the deviation candidate. Fifthly, repeat the iteration until all the deviation candidates are involved and get the optimal deviation with maximum fitness values. The real age plus the optimal deviation is taken as the brain pathological age. The experimental results showed that the separability was apparently improved. For normal control-Alzheimer’s disease (NC-AD), normal control-mild cognition impairment (NC-MCI), and MCI-AD, the average improvements were 0.178 (35.11%), 0.033 (14.47%), and 0.017 (39.53%), respectively. For NC-MCI-AD, the average improvement was 0.2287 (64.22%). The estimated brain pathological age could be not only more helpful to the classification of AD but also more precisely reflect accelerated brain aging. In conclusion, this paper offers a new method for brain age estimation that can distinguish different states of AD and can better reflect the extent of accelerated aging.
26 CFR 31.3402(h)(4)-1 - Other methods.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 15 2013-04-01 2013-04-01 false Other methods. 31.3402(h)(4)-1 Section 31.3402... Collection of Income Tax at Source § 31.3402(h)(4)-1 Other methods. (a) Maximum permissible deviations. An employer may use any other method of withholding under which the employer will deduct and withhold upon...
26 CFR 31.3402(h)(4)-1 - Other methods.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 15 2010-04-01 2010-04-01 false Other methods. 31.3402(h)(4)-1 Section 31.3402... Collection of Income Tax at Source § 31.3402(h)(4)-1 Other methods. (a) Maximum permissible deviations. An employer may use any other method of withholding under which the employer will deduct and withhold upon...
26 CFR 31.3402(h)(4)-1 - Other methods.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 15 2011-04-01 2011-04-01 false Other methods. 31.3402(h)(4)-1 Section 31.3402... Collection of Income Tax at Source § 31.3402(h)(4)-1 Other methods. (a) Maximum permissible deviations. An employer may use any other method of withholding under which the employer will deduct and withhold upon...
26 CFR 31.3402(h)(4)-1 - Other methods.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 15 2012-04-01 2012-04-01 false Other methods. 31.3402(h)(4)-1 Section 31.3402... Collection of Income Tax at Source § 31.3402(h)(4)-1 Other methods. (a) Maximum permissible deviations. An employer may use any other method of withholding under which the employer will deduct and withhold upon...
26 CFR 31.3402(h)(4)-1 - Other methods.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 15 2014-04-01 2014-04-01 false Other methods. 31.3402(h)(4)-1 Section 31.3402... Collection of Income Tax at Source § 31.3402(h)(4)-1 Other methods. (a) Maximum permissible deviations. An employer may use any other method of withholding under which the employer will deduct and withhold upon...
17 CFR 229.512 - (Item 512) Undertakings.
Code of Federal Regulations, 2011 CFR
2011-04-01
... INSTRUCTIONS FOR FILING FORMS UNDER SECURITIES ACT OF 1933, SECURITIES EXCHANGE ACT OF 1934 AND ENERGY POLICY... deviation from the low or high end of the estimated maximum offering range may be reflected in the form of... the registration statement is on Form S-8 (§ 239.16b of this chapter), and the information required to...
17 CFR 229.512 - (Item 512) Undertakings.
Code of Federal Regulations, 2012 CFR
2012-04-01
... INSTRUCTIONS FOR FILING FORMS UNDER SECURITIES ACT OF 1933, SECURITIES EXCHANGE ACT OF 1934 AND ENERGY POLICY... deviation from the low or high end of the estimated maximum offering range may be reflected in the form of... the registration statement is on Form S-8 (§ 239.16b of this chapter), and the information required to...
17 CFR 229.512 - (Item 512) Undertakings.
Code of Federal Regulations, 2014 CFR
2014-04-01
... INSTRUCTIONS FOR FILING FORMS UNDER SECURITIES ACT OF 1933, SECURITIES EXCHANGE ACT OF 1934 AND ENERGY POLICY... deviation from the low or high end of the estimated maximum offering range may be reflected in the form of... the registration statement is on Form S-8 (§ 239.16b of this chapter), and the information required to...
NASA Astrophysics Data System (ADS)
Taylor, Decarlos E.; Sausa, Rosario C.
2018-06-01
The determination of crystal structures plays an important role for model testing and validation, and understanding intra and intermolecular interactions that influence crystal packing. Here, we report the molecular structure of two recently synthesized energetic molecules, 3,3-bis-isoxazole-5,5‧-bis-methylene dinitrate (C8H6N4O8, BIDN) and bis-isoxazole tetramethylene tetranitrate (C10H8N6O14, BITN) determined by single crystal x-ray diffraction and solid state density functional theory (DFT). BIDN is composed of two planar alkyl nitrate groups (r.m.s deviation = 0.0004 (1) Å) bonded to two planar azole rings (r.m.s deviation = 0.001 (1) Å, whereas BITN is composed of four planar alkyl nitrate groups (average r.m.s deviation = 0.002 (1) Å) bonded to two planar azole rings (average r.m.s deviation = 0.002 (1) Å). The theoretical calculations predict very well the planarity of both the alkyl nitrate groups and rings for both compounds. Furthermore, they predict well the bond lengths and angles of both molecules with mean deviation values of 0.018 Å (BIDN) and 0.017 Å (BITN) and 0.481° (BIDN) and 0.747° (BITN). Overall, the DFT determined torsion angles agree well with those determined experimentally for both BIDN (average deviation = 1.139°) and BITN (average deviation = 0.604°). The theoretical cell constant values are in excellent agreement with those determined experimentally for both molecules, with the BIDN a cell value and β angle showing the largest deviation, 2.1% and -1.3%, respectively. Contacts between the atoms N and H dominate the intermolecular interactions of BIDN, whereas contacts involving the atoms O and H dominate the BITN intermolecular interactions. Electrostatic potential calculations at the B3LYP/6-31G* level reveal BIDN exhibits a lower sensitivity to impact compared to BITN.
Estimating potency for the Emax-model without attaining maximal effects.
Schoemaker, R C; van Gerven, J M; Cohen, A F
1998-10-01
The most widely applied model relating drug concentrations to effects is the Emax model. In practice, concentration-effect relationships often deviate from a simple linear relationship but without reaching a clear maximum because a further increase in concentration might be associated with unacceptable or distorting side effects. The parameters for the Emax model can only be estimated with reasonable precision if the curve shows sign of reaching a maximum, otherwise both EC50 and Emax estimates may be extremely imprecise. This paper provides a solution by introducing a new parameter (S0) equal to Emax/EC50 that can be used to characterize potency adequately even if there are no signs of a clear maximum. Simulations are presented to investigate the nature of the new parameter and published examples are used as illustration.
Matsunaga, Shunji; Nakamura, Kozo; Seichi, Atsushi; Yokoyama, Toru; Toh, Satoshi; Ichimura, Shoichi; Satomi, Kazuhiko; Endo, Kenji; Yamamoto, Kengo; Kato, Yoshiharu; Ito, Tatsuo; Tokuhashi, Yasuaki; Uchida, Kenzo; Baba, Hisatoshi; Kawahara, Norio; Tomita, Katsuro; Matsuyama, Yukihiro; Ishiguro, Naoki; Iwasaki, Motoki; Yoshikawa, Hideki; Yonenobu, Kazuo; Kawakami, Mamoru; Yoshida, Munehito; Inoue, Shinsuke; Tani, Toshikazu; Kaneko, Kazuo; Taguchi, Toshihiko; Imakiire, Takanori; Komiya, Setsuro
2008-11-15
A multicenter cohort study was performed retrospectively. To identify radiographic predictors for the development of myelopathy in patients with ossification of the posterior longitudinal ligaments (OPLL). The pathomechanism of myelopathy in the OPLL remains unknown. Some patients with large OPLL have not exhibited myelopathy for a long periods of time. Predicting the course of future neurologic deterioration in asyptomatic patients with OPLL is difficult at their initial visit. A total of 156 OPLL patients from 16 spine institutes with an average of 10.3 years of follow-up were reviewed. Subjects underwent a plain roentgenogram, computed tomography (CT), and magnetic resonance imaging of the cervical spine during the follow-up. The trauma history of the cervical spine, maximum percentage of spinal canal stenosis in a plain roentgenogram and CT, range of motion of the cervical spine, and axial ossified pattern in magnetic resonance imaging or CT were reviewed in relation to the existence of myelopathy. All 39 patients with greater than 60% spinal canal stenosis on the plain roentgenogram exhibited myelopathy. Of 117 patients with less than 60% spinal canal stenosis, 57 (49%) patients exhibited myelopathy. The range of motion of the cervical spine was significantly larger in patients with myelopathy than in those of without it. The axial ossified pattern could be classified into 2 types: a central type and a lateral deviated type. The incidence of myelopathy in patients with less than 60% spinal canal stenosis was significantly higher in the lateral deviated-type group than in the central-type group. Fifteen patients of 156 subjects developed trauma-induced myelopathy. Of the 15 patients, 13 had mixed-type OPLL and 2 had segmental-type OPLL. Static and dynamic factors were related to the development of myelopathy in OPLL.
NASA Astrophysics Data System (ADS)
Santillán, David; Mosquera, Juan-Carlos; Cueto-Felgueroso, Luis
2017-11-01
Hydraulic fracture trajectories in rocks and other materials are highly affected by spatial heterogeneity in their mechanical properties. Understanding the complexity and structure of fluid-driven fractures and their deviation from the predictions of homogenized theories is a practical problem in engineering and geoscience. We conduct a Monte Carlo simulation study to characterize the influence of heterogeneous mechanical properties on the trajectories of hydraulic fractures propagating in elastic media. We generate a large number of random fields of mechanical properties and simulate pressure-driven fracture propagation using a phase-field model. We model the mechanical response of the material as that of an elastic isotropic material with heterogeneous Young modulus and Griffith energy release rate, assuming that fractures propagate in the toughness-dominated regime. Our study shows that the variance and the spatial covariance of the mechanical properties are controlling factors in the tortuousness of the fracture paths. We characterize the deviation of fracture paths from the homogenous case statistically, and conclude that the maximum deviation grows linearly with the distance from the injection point. Additionally, fracture path deviations seem to be normally distributed, suggesting that fracture propagation in the toughness-dominated regime may be described as a random walk.
Analysis of Power Planning Deviation Influence on the Non-fossil Energy Development Goal
NASA Astrophysics Data System (ADS)
Xu, Wei-ting; Li, Ting; Ye, Qiang; Mi, Zhu; Ying, Liu; Tao, Yu-xuan
2017-05-01
Due to the international circumstances changes and domestic economic restructuring, the policies and planning of energy development have been adjusting in recent years, especially in energy power industry. Under these influences, the Chinese energy development goal “non-fossil energy accounts for 15% of the primary energy consumption” which planned to be realized in 2020 becomes uncertain. To ensure the goal can be achieved, a new energy power planning scheme is provided. Based on this planning scheme, the sensitivity analysis method and the maximum deviation method are proposed to quantify the influence of planning deviation on the target percentage. At the same time, the energy replacement is provided to fill the deviation. Research results shows that the main influence factors of target percentage is the hydro and nuclear power develop scale and their output channel construction. If the hydro and nuclear power capacity can’t reach their target scale, wind and solar power capacity can fill the vacancy instead. But if the vacancy of hydropower exceeds 58GW, or vacancy of nuclear power exceeds 27GW, the “15% goal” would be very difficult to achieve. Accelerating the construction of the hydropower output transmission lines helps to guarantee the "15% goal".
Marlière, Daniel Amaral Alves; Demétrio, Maurício Silva; Picinini, Leonardo Santos; De Oliveira, Rodrigo Guerra; Chaves Netto, Henrique Duque De Miranda
2018-01-01
Assess clinical studies regarding accuracy between virtual planning of computer-guided surgery and actual outcomes of dental implant placements in total edentulous alveolar ridges. A PubMed search was performed to identify only clinical studies published between 2011 and 2016, searching the following combinations of keywords: “Accuracy AND Computer-Assisted Surgery AND Dental Implants.” Study designs were identified using the terms: Case Reports, Clinical study, Randomized Controlled Trial, Systematic Reviews, Meta-Analysis, humans. Level of agreement between the authors in the study selection process was substantial (k = 0.767), and the study eligibility was considered excellent (k = 0.863). Seven articles were included in this review. They describe the use of bone and muco-supported guides, demonstrating angular deviations cervically and apically ranging from (minimum and maximum means), respectively, 1.85–8.4 (°), 0.17–2.17 (mm), and 0.77–2.86 (mm). Angular deviations obtained most inaccuracy in maxila. For cervical and apical deviations, accuracy was preponderantly lower in maxilla. Despite the similar deviations measurement approaches described, clinical relevance of this study may be useful to warn the surgeon that safety margins in clinical situations. PMID:29657542
Santillán, David; Mosquera, Juan-Carlos; Cueto-Felgueroso, Luis
2017-11-01
Hydraulic fracture trajectories in rocks and other materials are highly affected by spatial heterogeneity in their mechanical properties. Understanding the complexity and structure of fluid-driven fractures and their deviation from the predictions of homogenized theories is a practical problem in engineering and geoscience. We conduct a Monte Carlo simulation study to characterize the influence of heterogeneous mechanical properties on the trajectories of hydraulic fractures propagating in elastic media. We generate a large number of random fields of mechanical properties and simulate pressure-driven fracture propagation using a phase-field model. We model the mechanical response of the material as that of an elastic isotropic material with heterogeneous Young modulus and Griffith energy release rate, assuming that fractures propagate in the toughness-dominated regime. Our study shows that the variance and the spatial covariance of the mechanical properties are controlling factors in the tortuousness of the fracture paths. We characterize the deviation of fracture paths from the homogenous case statistically, and conclude that the maximum deviation grows linearly with the distance from the injection point. Additionally, fracture path deviations seem to be normally distributed, suggesting that fracture propagation in the toughness-dominated regime may be described as a random walk.
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups.
Hasija, Narender; Bala, Madhu; Goyal, Virender
2014-05-01
Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton's ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton's study. After measuring the teeth on all 100 patients, Bolton's analysis was performed. Results were compared with Bolton's means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85.
Chewing movements altered in the presence of temporomandibular joint internal derangements.
Radke, John C; Kull, Robert S; Sethi, Manminder S
2014-07-01
The objectives were to find specific factors that are mathematically distinct between the chewing timings, movement pattern shapes, variability, and movement velocities of: (1) normal asymptomatic subjects and (2) a group of subjects with verified temporomandibular joint (TMJ) internal derangements. Left- and right-sided chewing movement recordings of 28 subjects (34.5 ± 14.0 years) were randomly selected from a large database of patients exhibiting verified unilateral or bilateral TMJ internal derangements. The chewing movements of an age- and gender-matched control group of 20 asymptomatic subjects (32.5 ± 11.6 years, P>0.60) with verified normal TMJ function were also recorded. Means and standard deviations of the opening, closing, turning point, terminal chewing position, and velocity patterns were calculated. A two-tailed Student's t-test with unequal variances was used to compare the parameters between the two groups (alpha = 0.05). The dysfunctional group functioned significantly slower and with greater variability than the control group. The vertical dimension was consistently smaller in the dysfunctional group (P<0.00001). The terminal chewing position was significantly less precise in the dysfunctional group (vertical: P<0.002 and lateral: P<0.037). The maximum lateral width was significantly less (P<0.0071), and the peak and the average velocities were significantly lower (P<0.00001 for both) in the dysfunctional group. This group of dysfunctional subjects exhibited significantly slower, smaller, and more variable chewing patterns than the control group. The functional pattern of mastication appears to be significantly altered in the presence of an internal derangement of the TMJ.
March, Rod S.
2003-01-01
The 1996 measured winter snow, maximum winter snow, net, and annual balances in the Gulkana Glacier Basin were evaluated on the basis of meteorological, hydrological, and glaciological data. Averaged over the glacier, the measured winter snow balance was 0.87 meter on April 18, 1996, 1.1 standard deviation below the long-term average; the maximum winter snow balance, 1.06 meters, was reached on May 28, 1996; and the net balance (from August 30, 1995, to August 24, 1996) was -0.53 meter, 0.53 standard deviation below the long-term average. The annual balance (October 1, 1995, to September 30, 1996) was -0.37 meter. Area-averaged balances were reported using both the 1967 and 1993 area altitude distributions (the numbers previously given in this abstract use the 1993 area altitude distribution). Net balance was about 25 percent less negative using the 1993 area altitude distribution than the 1967 distribution. Annual average air temperature was 0.9 degree Celsius warmer than that recorded with the analog sensor used since 1966. Total precipitation catch for the year was 0.78 meter, 0.8 standard deviations below normal. The annual average wind speed was 3.5 meters per second in the first year of measuring wind speed. Annual runoff averaged 1.50 meters over the basin, 1.0 standard deviation below the long-term average. Glacier-surface altitude and ice-motion changes measured at three index sites document seasonal ice-speed and glacier-thickness changes. Both showed a continuation of a slowing and thinning trend present in the 1990s. The glacier terminus and lower ablation area were defined for 1996 with a handheld Global Positioning System survey of 126 locations spread out over about 4 kilometers on the lower glacier margin. From 1949 to 1996, the terminus retreated about 1,650 meters for an average retreat rate of 35 meters per year.
Zhang, Xuan; Chen, Zhenxian; Wang, Ling; Yang, Wenjian; Li, Dichen; Jin, Zhongmin
2015-07-01
Musculoskeletal lower limb models are widely used to predict the resultant contact force in the hip joint as a non-invasive alternative to instrumented implants. Previous musculoskeletal models based on rigid body assumptions treated the hip joint as an ideal sphere with only three rotational degrees of freedom. An musculoskeletal model that considered force-dependent kinematics with three additional translational degrees of freedom was developed and validated in this study by comparing it with a previous experimental measurement. A 32-mm femoral head against a polyethylene cup was considered in the musculoskeletal model for calculating the contact forces. The changes in the main modelling parameters were found to have little influence on the hip joint forces (relative deviation of peak value < 10 BW%, mean trial deviation < 20 BW%). The centre of the hip joint translation was more sensitive to the changes in the main modelling parameters, especially muscle recruitment type (relative deviation of peak value < 20%, mean trial deviation < 0.02 mm). The predicted hip contact forces showed consistent profiles, compared with the experimental measurements, except in the lateral-medial direction. The ratio-average analysis, based on the Bland-Altman's plots, showed better limits of agreement in climbing stairs (mean limits of agreement: -2.0 to 6.3 in walking, mean limits of agreement: -0.5 to 3.1 in climbing stairs). Better agreement of the predicted hip contact forces was also found during the stance phase. The force-dependent kinematics approach underestimated the maximum hip contact force by a mean value of 6.68 ± 1.75% BW compared with the experimental measurements. The predicted maximum translations of the hip joint centres were 0.125 ± 0.03 mm in level walking and 0.123 ± 0.005 mm in climbing stairs. © IMechE 2015.
Yang, Xianjin; Chen, Xiao; Carrigan, Charles R.; ...
2014-06-03
A parametric bootstrap approach is presented for uncertainty quantification (UQ) of CO₂ saturation derived from electrical resistance tomography (ERT) data collected at the Cranfield, Mississippi (USA) carbon sequestration site. There are many sources of uncertainty in ERT-derived CO₂ saturation, but we focus on how the ERT observation errors propagate to the estimated CO₂ saturation in a nonlinear inversion process. Our UQ approach consists of three steps. We first estimated the observational errors from a large number of reciprocal ERT measurements. The second step was to invert the pre-injection baseline data and the resulting resistivity tomograph was used as the priormore » information for nonlinear inversion of time-lapse data. We assigned a 3% random noise to the baseline model. Finally, we used a parametric bootstrap method to obtain bootstrap CO₂ saturation samples by deterministically solving a nonlinear inverse problem many times with resampled data and resampled baseline models. Then the mean and standard deviation of CO₂ saturation were calculated from the bootstrap samples. We found that the maximum standard deviation of CO₂ saturation was around 6% with a corresponding maximum saturation of 30% for a data set collected 100 days after injection began. There was no apparent spatial correlation between the mean and standard deviation of CO₂ saturation but the standard deviation values increased with time as the saturation increased. The uncertainty in CO₂ saturation also depends on the ERT reciprocal error threshold used to identify and remove noisy data and inversion constraints such as temporal roughness. Five hundred realizations requiring 3.5 h on a single 12-core node were needed for the nonlinear Monte Carlo inversion to arrive at stationary variances while the Markov Chain Monte Carlo (MCMC) stochastic inverse approach may expend days for a global search. This indicates that UQ of 2D or 3D ERT inverse problems can be performed on a laptop or desktop PC.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
LIU, B; Zhu, T
Purpose: The dose in the buildup region of a photon beam is usually determined by the transport of the primary secondary electrons and the contaminating electrons from accelerator head. This can be quantified by the electron disequilibrium factor, E, defined as the ratio between total dose and equilibrium dose (proportional to total kerma), E = 1 in regions beyond buildup region. Ecan be different among accelerators of different models and/or manufactures of the same machine. This study compares E in photon beams from different machine models/ Methods: Photon beam data such as fractional depth dose curve (FDD) and phantom scattermore » factors as a function of field size and phantom depth were measured for different Linac machines. E was extrapolated from these fractional depth dose data while taking into account inverse-square law. The ranges of secondary electron were chosen as 3 and 6 cm for 6 and 15 MV photon beams, respectively. The field sizes range from 2x2 to 40x40 cm{sup 2}. Results: The comparison indicates the standard deviations of electron contamination among different machines are about 2.4 - 3.3% at 5 mm depth for 6 MV and 1.2 - 3.9% at 1 cm depth for 15 MV for the same field size. The corresponding maximum deviations are 3.0 - 4.6% and 2 - 4% for 6 and 15 MV, respectively. Both standard and maximum deviations are independent of field sizes in the buildup region for 6 MV photons, and slightly decreasing with increasing field size at depths up to 1 cm for 15 MV photons. Conclusion: The deviations of electron disequilibrium factor for all studied Linacs are less than 3% beyond the depth of 0.5 cm for the photon beams for the full range of field sizes (2-40 cm) so long as they are from the same manufacturer.« less
NASA Astrophysics Data System (ADS)
Rock, N. M. S.
ROBUST calculates 53 statistics, plus significance levels for 6 hypothesis tests, on each of up to 52 variables. These together allow the following properties of the data distribution for each variable to be examined in detail: (1) Location. Three means (arithmetic, geometric, harmonic) are calculated, together with the midrange and 19 high-performance robust L-, M-, and W-estimates of location (combined, adaptive, trimmed estimates, etc.) (2) Scale. The standard deviation is calculated along with the H-spread/2 (≈ semi-interquartile range), the mean and median absolute deviations from both mean and median, and a biweight scale estimator. The 23 location and 6 scale estimators programmed cover all possible degrees of robustness. (3) Normality: Distributions are tested against the null hypothesis that they are normal, using the 3rd (√ h1) and 4th ( b 2) moments, Geary's ratio (mean deviation/standard deviation), Filliben's probability plot correlation coefficient, and a more robust test based on the biweight scale estimator. These statistics collectively are sensitive to most usual departures from normality. (4) Presence of outliers. The maximum and minimum values are assessed individually or jointly using Grubbs' maximum Studentized residuals, Harvey's and Dixon's criteria, and the Studentized range. For a single input variable, outliers can be either winsorized or eliminated and all estimates recalculated iteratively as desired. The following data-transformations also can be applied: linear, log 10, generalized Box Cox power (including log, reciprocal, and square root), exponentiation, and standardization. For more than one variable, all results are tabulated in a single run of ROBUST. Further options are incorporated to assess ratios (of two variables) as well as discrete variables, and be concerned with missing data. Cumulative S-plots (for assessing normality graphically) also can be generated. The mutual consistency or inconsistency of all these measures helps to detect errors in data as well as to assess data-distributions themselves.
Active laser ranging with frequency transfer using frequency comb
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hongyuan; Wei, Haoyun; Yang, Honglei
2016-05-02
A comb-based active laser ranging scheme is proposed for enhanced distance resolution and a common time standard for the entire system. Three frequency combs with different repetition rates are used as light sources at the two ends where the distance is measured. Pulse positions are determined through asynchronous optical sampling and type II second harmonic generation. Results show that the system achieves a maximum residual of 379.6 nm and a standard deviation of 92.9 nm with 2000 averages over 23.6 m. Moreover, as for the frequency transfer, an atom clock and an adjustable signal generator, synchronized to the atom clock, are used asmore » time standards for the two ends to appraise the frequency deviation introduced by the proposed system. The system achieves a residual fractional deviation of 1.3 × 10{sup −16} for 1 s, allowing precise frequency transfer between the two clocks at the two ends.« less
Qiu, Zhong-Feng; Xi, Hong-Yan; He, Yi-Jun; Chen, Jay-Chung; Jian, Wei-Jun
2006-08-01
For the purpose of detecting and forecasting research of red tides to reduce the loss, a semi-analytic algorithm to retrieve chlorophyll-a concentrations was established in the area where red tides often brought out, according to the data collected during the red tides cruise in the East China Sea in April 2002. In the algorithm, empirical equations were made based on the coefficients from the in-situ data, including the optical properties of the research area. The in-situ data were used to validate the algorithm. The discrepancy of chlorophyll-a absorption coefficients and concentrations are mainly located in the region of 30%. The root mean deviation of the chlorophyll-a concentrations between the observed and the calculated is 0.24, the maximum relative deviation 40.93%, the mean relative deviation 18.83% and the correlation coefficient 0.83. The results show that the precision of the algorithm is high and the algorithm is fit for the research area.
Objective Motion Cueing Criteria Investigation Based on Three Flight Tasks
NASA Technical Reports Server (NTRS)
Zaal, Petrus M. T.; Schroeder, Jeffery A.; Chung, William W.
2015-01-01
This paper intends to help establish fidelity criteria to accompany the simulator motion system diagnostic test specified by the International Civil Aviation Organization. Twelve air- line transport pilots flew three tasks in the NASA Vertical Motion Simulator under four different motion conditions. The experiment used three different hexapod motion configurations, each with a different tradeoff between motion filter gain and break frequency, and one large motion configuration that utilized as much of the simulator's motion space as possible. The motion condition significantly affected: 1) pilot motion fidelity ratings, and sink rate and lateral deviation at touchdown for the approach and landing task, 2) pilot motion fidelity ratings, roll deviations, maximum pitch rate, and number of stick shaker activations in the stall task, and 3) heading deviation after an engine failure in the takeoff task. Significant differences in pilot-vehicle performance were used to define initial objective motion cueing criteria boundaries. These initial fidelity boundaries show promise but need refinement.
Automating linear accelerator quality assurance.
Eckhause, Tobias; Al-Hallaq, Hania; Ritter, Timothy; DeMarco, John; Farrey, Karl; Pawlicki, Todd; Kim, Gwe-Ya; Popple, Richard; Sharma, Vijeshwar; Perez, Mario; Park, SungYong; Booth, Jeremy T; Thorwarth, Ryan; Moran, Jean M
2015-10-01
The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.
Braithwaite, Susan S; Umpierrez, Guillermo E; Chase, J Geoffrey
2013-09-01
Group metrics are described to quantify blood glucose (BG) variability of hospitalized patients. The "multiplicative surrogate standard deviation" (MSSD) is the reverse-transformed group mean of the standard deviations (SDs) of the logarithmically transformed BG data set of each patient. The "geometric group mean" (GGM) is the reverse-transformed group mean of the means of the logarithmically transformed BG data set of each patient. Before reverse transformation is performed, the mean of means and mean of SDs each has its own SD, which becomes a multiplicative standard deviation (MSD) after reverse transformation. Statistical predictions and comparisons of parametric or nonparametric tests remain valid after reverse transformation. A subset of a previously published BG data set of 20 critically ill patients from the first 72 h of treatment under the SPRINT protocol was transformed logarithmically. After rank ordering according to the SD of the logarithmically transformed BG data of each patient, the cohort was divided into two equal groups, those having lower or higher variability. For the entire cohort, the GGM was 106 (÷/× 1.07) mg/dl, and MSSD was 1.24 (÷/× 1.07). For the subgroups having lower and higher variability, respectively, the GGM did not differ, 104 (÷/× 1.07) versus 109 (÷/× 1.07) mg/dl, but the MSSD differed, 1.17 (÷/× 1.03) versus 1.31 (÷/× 1.05), p = .00004. By using the MSSD with its MSD, groups can be characterized and compared according to glycemic variability of individual patient members. © 2013 Diabetes Technology Society.
Effectiveness of caudal septal extension graft application in endonasal septoplasty.
Karadavut, Yunus; Akyıldız, Ilker; Karadaş, Hatice; Dinç, Aykut Erdem; Tulacı, Gökçe; Tastan, Eren
Septal deviation is a common disease seen in daily otorhinolaryngology practice and septoplasty is a commonly performed surgical procedure. Caudal septum deviation is also a challenging pathology for ear, nose, and throat specialists. Many techniques are defined for caudal septal deviation. To evaluate the effectiveness of caudal septal extension graft (CSEG) application in patients who underwent endonasal septoplasty for a short and deviated nasal septum. Forty patients with nasal septal deviation, short nasal septum, and weak nasal tip support who underwent endonasal septoplasty with or without CSEG placement between August 2012 and June 2013 were enrolled in this study. Twenty patients underwent endonasal septoplasty with CSEG placement. The rest of the group, who rejected auricular or costal cartilage harvest for CSEG placement, underwent only endonasal septoplasty without any additional intervention. Using the Nasal Obstruction Symptom Evaluation (NOSE) and Rhinoplasty Outcome Evaluation (ROE) questionnaires, pre- and post-operative acoustic rhinometer measurements were evaluated to assess the effect of CESG placement on nasal obstruction. In the control group, preoperative and postoperative minimal cross-sectional areas (MCA1) were 0.44±0.10cm 2 and 0.60±0.11cm 2 , respectively (p<0.001). In the study group, pre- and postoperative MCA1 values were 0.45±0.16cm 2 and 0.67±0.16cm 2 , respectively (p<0.01). In the control group, the nasal cavity volume (VOL1) value was 1.71±0.21mL preoperatively and 1.94±0.17mL postoperatively (p<0.001). In the study group, pre- and postoperative VOL1s were 1.72±0.15mL and 1.97±0.12mL, respectively (p<0.001). Statistical analysis of postoperative MCA1 and VOL1 values in the study and the control groups could not detect any significant intergroup difference (p=0.093 and 0.432, respectively). In the study group, mean nasolabial angles were 78.15±4.26° and 90.70±2.38°, respectively (p<0.001). Endonasal septoplasty with CESG placement is an effective surgical procedure with minimal complication rate for subjects who have a deviated, short nasal septum and weak nasal tip support. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
ESTIMATION OF EFFECTIVE SHEAR STRESS WORKING ON FLAT SHEET MEMBRANE USING FLUIDIZED MEDIA IN MBRs
NASA Astrophysics Data System (ADS)
Zaw, Hlwan Moe; Li, Tairi; Nagaoka, Hiroshi; Mishima, Iori
This study was aimed at estimating effective shear stress working on flat sheet membrane by the addition of fluidized media in MBRs. In both of laboratory-scale aeration tanks with and without fluidized media, shear stress variations on membrane surface and water phase velocity variations were measured and MBR operation was conducted. For the evaluation of the effective shear stress working on membrane surface to mitigate membrane surface, simulation of trans-membrane pressure increase was conducted. It was shown that the time-averaged absolute value of shear stress was smaller in the reactor with fluidized media than without fluidized media. However, due to strong turbulence in the reactor with fluidized media caused by interaction between water-phase and media and also due to the direct interaction between membrane surface and fluidized media, standard deviation of shear stress on membrane surface was larger in the reactor with fluidized media than without media. Histograms of shear stress variation data were fitted well to normal distribution curves and mean plus three times of standard deviation was defined to be a maximum shear stress value. By applying the defined maximum shear stress to a membrane fouling model, trans-membrane pressure curve in the MBR experiment was simulated well by the fouling model indicting that the maximum shear stress, not time-averaged shear stress, can be regarded as an effective shear stress to prevent membrane fouling in submerged flat-sheet MBRs.
Respiratory muscle strength test: is it realistic in young children?
Heinzmann-Filho, João Paulo; Donadio, Márcio Vinícius Fagundes
2015-01-01
Objective: To determine the success rate of the manovacuometry test in children between 4 and 12 years of age. Methods: Cross-sectional study involving children and adolescents from 4 to 12 years of age, enrolled in three basic education schools. All subjects had the anthropometric and respiratory muscle strength (maximum inspiratory pressure and maximum expiratory pressure) data measured. Students whose parents did not authorize participation or who did not want to undergo the test were excluded. The test was considered successful when the subject reached acceptability (no air leaks) and reproducibility (variation <10% between the two major maneuvers) criteria established by guidelines. Failure was defined when subjects did not meet the above criteria. Data were expressed as mean and standard deviation and the categorical variables in absolute and relative frequency. The comparison between proportions was performed using the chi-square test. Results: We included 196 children and adolescents, mean age of 8.4±2.5 years, 53.1% female. The success rate of the manovacuometry test in children and adolescents evaluated was 92.3%. When comparing the differences between the success rates of preschool children with those children and adolescents of school age, there was a significantly lower success rate in the pre-school (85.1%) group compared to the school group (94.6%) (p=0.032). However, no significant differences (p=0.575) were found when gender comparisons were performed. Conclusions: The manovacuometry test showed a high success rate in both preschool and school population assessed. Furthermore, the rate of success appears to be related to aging. PMID:26137867
On the variation of the Nimbus 7 total solar irradiance
NASA Technical Reports Server (NTRS)
Wilson, Robert M.
1992-01-01
For the interval December 1978 to April 1991, the value of the mean total solar irradiance, as measured by the Nimbus-7 Earth Radiation Budget Experiment channel 10C, was 1,372.02 Wm(exp -2), having a standard deviation of 0.65 Wm(exp -2), a coefficient of variation (mean divided by the standard deviation) of 0.047 percent, and a normal deviate z (a measure of the randomness of the data) of -8.019 (inferring a highly significant non-random variation in the solar irradiance measurements, presumably related to the action of the solar cycle). Comparison of the 12-month moving average (also called the 13-month running mean) of solar irradiance to those of the usual descriptors of the solar cycle (i.e., sunspot number, 10.7-cm solar radio flux, and total corrected sunspot area) suggests possibly significant temporal differences. For example, solar irradiance is found to have been greatest on or before mid 1979 (leading solar maximum for cycle 21), lowest in early 1987 (lagging solar minimum for cycle 22), and was rising again through late 1990 (thus, lagging solar maximum for cycle 22), having last reported values below those that were seen in 1979 (even though cycles 21 and 22 were of comparable strength). Presuming a genuine correlation between solar irradiance and the solar cycle (in particular, sunspot number) one infers that the correlation is weak (having a coefficient of correlation r less than 0.84) and that major excursions (both as 'excesses' and 'deficits') have occurred (about every 2 to 3 years, perhaps suggesting a pulsating Sun).
Nomoto, Masahiro; Mizuno, Yoshikuni; Kondo, Tomoyoshi; Hasegawa, Kazuko; Murata, Miho; Takeuchi, Masahiro; Ikeda, Junji; Tomida, Takayuki; Hattori, Nobutaka
2014-10-01
Rotigotine, a non-ergot dopamine receptor agonist, offers potential for continuous dopaminergic stimulation that could avoid the fluctuations observed with traditional treatments. We conducted a randomized, double-blind, placebo-controlled trial in Japanese patients with advanced Parkinson's disease (PD) to investigate the efficacy and safety of rotigotine. Inclusion criteria included the presence of motor complications, such as wearing off, on-off, delayed-on/no-on, any circumstances that could interfere with levodopa dose escalation because of side effects, or declining levodopa efficacy. The enrolled patients received once-daily applications of rotigotine transdermal patches or matched placebo patches. A total of 174 patients were randomly assigned to rotigotine (87 patients) or placebo (87 patients). The full analysis set included 172 patients (86 for the rotigotine group and 86 for the placebo group). The maximum maintenance dose of rotigotine was set at 16 mg/24 h. The changes in unified PD rating scale Part III scores from baseline to the end of the trial were -10.1 ± 9.0 (mean ± standard deviation) in the rotigotine group and -4.4 ± 7.4 in the placebo group (p < 0.001). There was a significantly greater reduction in the off-time (p = 0.014) in the rotigotine group. Rotigotine was well tolerated, with serious adverse events being reported in only three patients in each group. Rotigotine at doses of up to 16 mg/24 h is efficacious and safe in Japanese patients with advanced PD.
Kwon, Deukwoo; Reis, Isildinha M
2015-08-12
When conducting a meta-analysis of a continuous outcome, estimated means and standard deviations from the selected studies are required in order to obtain an overall estimate of the mean effect and its confidence interval. If these quantities are not directly reported in the publications, they must be estimated from other reported summary statistics, such as the median, the minimum, the maximum, and quartiles. We propose a simulation-based estimation approach using the Approximate Bayesian Computation (ABC) technique for estimating mean and standard deviation based on various sets of summary statistics found in published studies. We conduct a simulation study to compare the proposed ABC method with the existing methods of Hozo et al. (2005), Bland (2015), and Wan et al. (2014). In the estimation of the standard deviation, our ABC method performs better than the other methods when data are generated from skewed or heavy-tailed distributions. The corresponding average relative error (ARE) approaches zero as sample size increases. In data generated from the normal distribution, our ABC performs well. However, the Wan et al. method is best for estimating standard deviation under normal distribution. In the estimation of the mean, our ABC method is best regardless of assumed distribution. ABC is a flexible method for estimating the study-specific mean and standard deviation for meta-analysis, especially with underlying skewed or heavy-tailed distributions. The ABC method can be applied using other reported summary statistics such as the posterior mean and 95 % credible interval when Bayesian analysis has been employed.
Comparison of polyurethane with cyanoacrylate in hemostasis of vascular injury in guinea pigs.
Kubrusly, Luiz Fernando; Formighieri, Marina Simões; Lago, José Vitor Martins; Graça, Yorgos Luiz Santos de Salles; Sobral, Ana Cristina Lira; Lago, Marianna Martins
2015-01-01
To evaluate the behavior of castor oil-derived polyurethane as a hemostatic agent and tissue response after abdominal aortic injury and to compare it with 2-octyl-cyanoacrylate. Twenty-four Guinea Pigs were randomly divided into three groups of eight animals (I, II, and III). The infrarenal abdominal aorta was dissected, clamped proximally and distally to the vascular puncture site. In group I (control), hemostasis was achieved with digital pressure; in group II (polyurethane) castor oil-derived polyurethane was applied, and in group III (cyanoacrylate), 2-octyl-cyanoacrylate was used. Group II was subdivided into IIA and IIB according to the time of preparation of the hemostatic agent. Mean blood loss in groups IIA, IIB and III was 0.002 grams (g), 0.008 g, and 0.170 g, with standard deviation of 0.005 g, 0.005 g, and 0.424 g, respectively (P=0.069). The drying time for cyanoacrylate averaged 81.5 seconds (s) (standard deviation: 51.5 seconds) and 126.1 s (standard deviation: 23.0 s) for polyurethane B (P=0.046). However, there was a trend (P=0.069) for cyanoacrylate to dry more slowly than polyurethane A (mean: 40.5 s; SD: 8.6 s). Furthermore, polyurethane A had a shorter drying time than polyurethane B (P=0.003), mean IIA of 40.5 s (standard deviation: 8.6 s). In group III, 100% of the animals had mild/severe fibrosis, while in group II only 12.5% showed this degree of fibrosis (P=0.001). Polyurethane derived from castor oil showed similar hemostatic behavior to octyl-2-cyanoacrylate. There was less perivascular tissue response with polyurethane when compared with cyanoacrylate.
Comparison of polyurethane with cyanoacrylate in hemostasis of vascular injury in guinea pigs
Kubrusly, Luiz Fernando; Formighieri, Marina Simões; Lago, José Vitor Martins; Graça, Yorgos Luiz Santos de Salles; Sobral, Ana Cristina Lira; Lago, Marianna Martins
2015-01-01
Objective To evaluate the behavior of castor oil-derived polyurethane as a hemostatic agent and tissue response after abdominal aortic injury and to compare it with 2-octyl-cyanoacrylate. Methods Twenty-four Guinea Pigs were randomly divided into three groups of eight animals (I, II, and III). The infrarenal abdominal aorta was dissected, clamped proximally and distally to the vascular puncture site. In group I (control), hemostasis was achieved with digital pressure; in group II (polyurethane) castor oil-derived polyurethane was applied, and in group III (cyanoacrylate), 2-octyl-cyanoacrylate was used. Group II was subdivided into IIA and IIB according to the time of preparation of the hemostatic agent. Results Mean blood loss in groups IIA, IIB and III was 0.002 grams (g), 0.008 g, and 0.170 g, with standard deviation of 0.005 g, 0.005 g, and 0.424 g, respectively (P=0.069). The drying time for cyanoacrylate averaged 81.5 seconds (s) (standard deviation: 51.5 seconds) and 126.1 s (standard deviation: 23.0 s) for polyurethane B (P=0.046). However, there was a trend (P=0.069) for cyanoacrylate to dry more slowly than polyurethane A (mean: 40.5 s; SD: 8.6 s). Furthermore, polyurethane A had a shorter drying time than polyurethane B (P=0.003), mean IIA of 40.5 s (standard deviation: 8.6 s). In group III, 100% of the animals had mild/severe fibrosis, while in group II only 12.5% showed this degree of fibrosis (P=0.001). Conclusion Polyurethane derived from castor oil showed similar hemostatic behavior to octyl-2-cyanoacrylate. There was less perivascular tissue response with polyurethane when compared with cyanoacrylate. PMID:25859876
Flores-Alamo, Marcos; del Carmen Romero-Quiroz, María; Morgado, Jorge
2010-01-01
In the title compound {systematic name: 2-[(E)-but-2-en-1-yl]isoindoline-1,3-dione}, C12H11NO2, the phthalimide ring system is essentially planar, with a maximum deviation of 0.008 (1) Å, while the plane of the N-crotyl substituent is orthogonal to the phthalimide ring system, making a dihedral angle of 87.5 (1)°. PMID:21589502
Context Aware Routing Management Architecture for Airborne Networks
2012-03-22
awareness, increased survivability, 2 higher operation tempo , greater lethality, improve speed of command and certain degree of self-synchronization [35...first two sets of experiments. This error model simulates deviations from predetermined routes as well as variations on signal strength for radio...routes computed using Maximum Concurrent Multi-Commodity flow algorithm are not susceptible to rapid topology variations induced by noise. 57 5
Baek, Chaehwan; Paeng, Jun-Young; Lee, Janice S; Hong, Jongrak
2012-05-01
A systematic classification is needed for the diagnosis and surgical treatment of facial asymmetry. The purposes of this study were to analyze the skeletal structures of patients with facial asymmetry and to objectively classify these patients into groups according to these structural characteristics. Patients with facial asymmetry and recent computed tomographic images from 2005 through 2009 were included in this study, which was approved by the institutional review board. Linear measurements, angles, and reference planes on 3-dimensional computed tomograms were obtained, including maxillary (upper midline deviation, maxilla canting, and arch form discrepancy) and mandibular (menton deviation, gonion to midsagittal plane, ramus height, and frontal ramus inclination) measurements. All measurements were analyzed using paired t tests with Bonferroni correction followed by K-means cluster analysis using SPSS 13.0 to determine an objective classification of facial asymmetry in the enrolled patients. Kruskal-Wallis test was performed to verify differences among clustered groups. P < .05 was considered statistically significant. Forty-three patients (18 male, 25 female) were included in the study. They were classified into 4 groups based on cluster analysis. Their mean age was 24.3 ± 4.4 years. Group 1 included subjects (44% of patients) with asymmetry caused by a shift or lateralization of the mandibular body. Group 2 included subjects (39%) with a significant difference between the left and right ramus height with menton deviation to the short side. Group 3 included subjects (12%) with atypical asymmetry, including deviation of the menton to the short side, prominence of the angle/gonion on the larger side, and reverse maxillary canting. Group 4 included subjects (5%) with severe maxillary canting, ramus height differences, and menton deviation to the short side. In this study, patients with asymmetry were classified into 4 statistically distinct groups according to their anatomic features. This diagnostic classification method will assist in treatment planning for patients with facial asymmetry and may be used to explore the etiology of these variants of facial asymmetry. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
A spiral-based volumetric acquisition for MR temperature imaging.
Fielden, Samuel W; Feng, Xue; Zhao, Li; Miller, G Wilson; Geeslin, Matthew; Dallapiazza, Robert F; Elias, W Jeffrey; Wintermark, Max; Butts Pauly, Kim; Meyer, Craig H
2018-06-01
To develop a rapid pulse sequence for volumetric MR thermometry. Simulations were carried out to assess temperature deviation, focal spot distortion/blurring, and focal spot shift across a range of readout durations and maximum temperatures for Cartesian, spiral-out, and retraced spiral-in/out (RIO) trajectories. The RIO trajectory was applied for stack-of-spirals 3D imaging on a real-time imaging platform and preliminary evaluation was carried out compared to a standard 2D sequence in vivo using a swine brain model, comparing maximum and mean temperatures measured between the two methods, as well as the temporal standard deviation measured by the two methods. In simulations, low-bandwidth Cartesian trajectories showed substantial shift of the focal spot, whereas both spiral trajectories showed no shift while maintaining focal spot geometry. In vivo, the 3D sequence achieved real-time 4D monitoring of thermometry, with an update time of 2.9-3.3 s. Spiral imaging, and RIO imaging in particular, is an effective way to speed up volumetric MR thermometry. Magn Reson Med 79:3122-3127, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Xiong, Qingang; Ramirez, Emilio; Pannala, Sreekanth; ...
2015-10-09
The impact of bubbling bed hydrodynamics on temporal variations in the exit tar yield for biomass fast pyrolysis was investigated using computational simulations of an experimental laboratory-scale reactor. A multi-fluid computational fluid dynamics model was employed to simulate the differential conservation equations in the reactor, and this was combined with a multi-component, multi-step pyrolysis kinetics scheme for biomass to account for chemical reactions. The predicted mean tar yields at the reactor exit appear to match corresponding experimental observations. Parametric studies predicted that increasing the fluidization velocity should improve the mean tar yield but increase its temporal variations. Increases in themore » mean tar yield coincide with reducing the diameter of sand particles or increasing the initial sand bed height. However, trends in tar yield variability are more complex than the trends in mean yield. The standard deviation in tar yield reaches a maximum with changes in sand particle size. As a result, the standard deviation in tar yield increases with the increases in initial bed height in freely bubbling state, while reaches a maximum in slugging state.« less
Image dynamic range test and evaluation of Gaofen-2 dual cameras
NASA Astrophysics Data System (ADS)
Zhang, Zhenhua; Gan, Fuping; Wei, Dandan
2015-12-01
In order to fully understand the dynamic range of Gaofen-2 satellite data and support the data processing, application and next satellites development, in this article, we evaluated the dynamic range by calculating some statistics such as maximum ,minimum, average and stand deviation of four images obtained at the same time by Gaofen-2 dual cameras in Beijing area; then the maximum ,minimum, average and stand deviation of each longitudinal overlap of PMS1,PMS2 were calculated respectively for the evaluation of each camera's dynamic range consistency; and these four statistics of each latitudinal overlap of PMS1,PMS2 were calculated respectively for the evaluation of the dynamic range consistency between PMS1 and PMS2 at last. The results suggest that there is a wide dynamic range of DN value in the image obtained by PMS1 and PMS2 which contains rich information of ground objects; in general, the consistency of dynamic range between the single camera images is in close agreement, but also a little difference, so do the dual cameras. The consistency of dynamic range between the single camera images is better than the dual cameras'.
Alignment of multiradiation isocenters for megavoltage photon beam
Zhang, Yin; Ding, Kai; Cowan, Garth; Tryggestad, Erik; Armour, Elwood
2015-01-01
The accurate measurement of the linear accelerator (linac) radiation isocenter is critical, especially for stereotactic treatment. Traditional quality assurance (QA) procedure focuses on the measurement of single radiation isocenter, usually of 6 megavoltage (MV) photon beams. Single radiation isocenter is also commonly assumed in treatment planning systems (TPS). Due to different flattening filters and bending magnet and steering parameters, the radiation isocenter of one energy mode can deviate from another if no special effort was devoted. We present the first experience of the multiradiation isocenters alignment on an Elekta linac, as well as its corresponding QA procedure and clinical impact. An 8 mm ball‐bearing (BB) phantom was placed at the 6 MV radiation isocenter using an Elekta isocenter search algorithm, based on portal images. The 3D radiation isocenter shifts of other photon energy modes relative to the 6 MV were determined. Beam profile scanning for different field sizes was used as an independent method to determine the 2D multiradiation isocenters alignment. To quantify the impact of radiation isocenter offset on targeting accuracy, the 10 MV radiation isocenter was manually offset from that for 6 MV by adjusting the bending magnet current. Because our table isocenter was mechanically aligned to the 6 MV radiation isocenter, the deviation of the table isocentric rotation from the "shifted" 10 MV radiation isocenter after bending magnet adjustment was assessed. Winston‐Lutz test was also performed to confirm the overall radiation isocenter positioning accuracy for all photon energies. The portal image method showed the radiation isocenter of the 10 MV flattening filter‐free mode deviated from others before beam parameter adjustment. After the adjustment, the deviation was greatly improved from 0.96 to 0.35 mm relative to the 6 MV radiation isocenter. The same finding was confirmed by the profile‐scanning method. The maximum deviation of the table isocentric rotation from the 10 MV radiation isocenter was observed to linearly increase with the offset between 6 and 10 MV radiation isocenter; 1 mm radiation isocenter offset can translate to almost 2 mm maximum deviation of the table isocentric rotation from the 10 MV radiation isocenter. The alignment of the multiradiation isocenters is particularly important for high‐precision radiotherapy. Our study provides the medical physics community with a quantitative measure of the multiradiation isocenters alignment. A routine QA method should be considered, to examine the radiation isocenters alignment during the linac acceptance. PACS number: 87.55.Qr, 87.56.bd, 87.56.Fc PMID:26699586
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chin-Cheng, E-mail: chen.ccc@gmail.com; Chang, Chang; Mah, Dennis
Purpose: The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. Methods: A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0–226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to themore » beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. Results: Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. Conclusions: For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.« less
Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun
2014-12-19
In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. In this paper, we propose to improve the existing literature in several directions. First, we show that the sample standard deviation estimation in Hozo et al.'s method (BMC Med Res Methodol 5:13, 2005) has some serious limitations and is always less satisfactory in practice. Inspired by this, we propose a new estimation method by incorporating the sample size. Second, we systematically study the sample mean and standard deviation estimation problem under several other interesting settings where the interquartile range is also available for the trials. We demonstrate the performance of the proposed methods through simulation studies for the three frequently encountered scenarios, respectively. For the first two scenarios, our method greatly improves existing methods and provides a nearly unbiased estimate of the true sample standard deviation for normal data and a slightly biased estimate for skewed data. For the third scenario, our method still performs very well for both normal data and skewed data. Furthermore, we compare the estimators of the sample mean and standard deviation under all three scenarios and present some suggestions on which scenario is preferred in real-world applications. In this paper, we discuss different approximation methods in the estimation of the sample mean and standard deviation and propose some new estimation methods to improve the existing literature. We conclude our work with a summary table (an Excel spread sheet including all formulas) that serves as a comprehensive guidance for performing meta-analysis in different situations.
Technical Note: Spot characteristic stability for proton pencil beam scanning.
Chen, Chin-Cheng; Chang, Chang; Moyers, Michael F; Gao, Mingcheng; Mah, Dennis
2016-02-01
The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0-226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to the beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.
Simulation of alnico coercivity
Ke, Liqin; Skomski, Ralph; Hoffmann, Todd D.; ...
2017-07-10
Micromagnetic simulations of alnico show substantial deviations from Stoner-Wohlfarth behavior due to the unique size and spatial distribution of the rod-like Fe-Co phase formed during spinodal decomposition in an external magnetic field. Furthemore, the maximum coercivity is limited by single-rod effects, especially deviations from ellipsoidal shape, and by interactions between the rods. In both the exchange interaction between connected rods and magnetostatic we consider the interaction between rods, and the results of our calculations show good agreement with recent experiments. Unlike systems dominated by magnetocrystalline anisotropy, coercivity in alnico is highly dependent on size, shape, and geometric distribution of themore » Fe-Co phase, all factors that can be tuned with appropriate chemistry and thermal-magnetic annealing.« less
Porcelain surface conditioning protocols and shear bond strength of orthodontic brackets.
Lestrade, Ashley M; Ballard, Richard W; Xu, Xiaoming; Yu, Qingzhao; Kee, Edwin L; Armbruster, Paul C
2016-05-01
The objective of the present study was to determine which of six bonding protocols yielded a clinically acceptable shear bond strength (SBS) of metal orthodontic brackets to CAD/CAM lithium disilicate porcelain restorations. A secondary aim was to determine which bonding protocol produced the least surface damage at debond. Sixty lithium disilicate samples were fabricated to replicate the facial surface of a mandibular first molar using a CEREC CAD/CAM machine. The samples were split into six test groups, each of which received different mechanical/chemical pretreatment protocols to roughen the porcelain surface prior to bonding a molar orthodontic attachment. Shear bond strength testing was conducted using an Instron machine. The mean, maximum, minimal, and standard deviation SBS values for each sample group including an enamel control were calculated. A t-test was used to evaluate the statistical significance between the groups. No significant differences were found in SBS values, with the exception of surface roughening with a green stone prior to HFA and silane treatment. This protocol yielded slightly higher bond strength which was statistically significant. Chemical treatment alone with HFA/silane yielded SBS values within an acceptable clinical range to withstand forces applied by orthodontic treatment and potentially eliminates the need to mechanically roughen the ceramic surface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dalaryd, Mårten, E-mail: Marten.Dalaryd@med.lu.se; Knöös, Tommy; Ceberg, Crister
Purpose: There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for flattening filter free (FFF) beams, the relationship between the beam-quality specifier TPR{sub 20,10} and the Spencer–Attix restricted water-to-air mass collision stopping-power ratios, (L{sup -}/ρ){sub air}{sup water}, may have to be refined in order to be used with equivalent accuracy as for beams with a flattening filter. The purpose of this work was twofold. First, to studymore » the relationship between TPR{sub 20,10} and (L{sup -}/ρ){sub air}{sup water} for FFF beams, where the flattening filter has been replaced by a metal plate as in most clinical FFF beams. Second, to investigate the potential of increasing the accuracy in determining (L{sup -}/ρ){sub air}{sup water} by adding another beam-quality metric, TPR{sub 10,5}. The relationship between (L{sup -}/ρ){sub air}{sup water} and %dd(10){sub x} for beams with and without a flattening filter was also included in this study. Methods: A total of 24 realistic photon beams (10 with and 14 without a flattening filter) from three different treatment units have been used to calculate (L{sup -}/ρ){sub air}{sup water}, TPR{sub 20,10}, and TPR{sub 10,5} using the EGSnrc Monte Carlo package. The relationship between (L{sup -}/ρ){sub air}{sup water} and the dual beam-quality specifier TPR{sub 20,10} and TPR{sub 10,5} was described by a simple bilinear equation. The relationship between the photon beam-quality specifier %dd(10){sub x} used in the AAPM’s TG-51 dosimetry protocol and (L{sup -}/ρ){sub air}{sup water} was also investigated for the beams used in this study, by calculating the photon component of the percentage depth dose at 10 cm depth with SSD 100 cm. Results: The calculated (L{sup -}/ρ){sub air}{sup water} for beams without a flattening filter was 0.3% lower, on average, than for beams with a flattening filter and comparable TPR{sub 20,10}. Using the relationship in IAEA, TRS-398 resulted in a root mean square deviation (RMSD) of 0.0028 with a maximum deviation of 0.0043 (0.39%) from Monte Carlo calculated values. For all beams in this study, the RMSD between the proposed model and the Monte Carlo calculated values was 0.0006 with a maximum deviation of 0.0013 (0.1%). Using an earlier proposed relationship [Xiong and Rogers, Med. Phys. 35, 2104–2109 (2008)] between %dd(10){sub x} and (L{sup -}/ρ){sub air}{sup water} gave a RMSD of 0.0018 with a maximum deviation of 0.0029 (0.26%) for all beams in this study (compared to RMSD 0.0015 and a maximum deviation of 0.0048 (0.47%) for the relationship used in AAPM TG-51 published by Almond et al. [Med. Phys. 26, 1847–1870 (1999)]). Conclusions: Using TPR{sub 20,10} as a beam-quality specifier, for the flattening filter free beams used in this study, gave a maximum difference of 0.39% between (L{sup -}/ρ){sub air}{sup water} predicted using IAEA TRS-398 and Monte Carlo calculations. An additional parameter for determining (L{sup -}/ρ){sub air}{sup water} has been presented. This parameter is easy to measure; it requires only an additional dose measurement at 5 cm depth with SSD 95 cm, and provides information for accurate determination of the (L{sup -}/ρ){sub air}{sup water} ratio for beams both with and without a flattening filter at the investigated energies.« less
Analysis of ionospheric irregularities during total solar eclipse 2016 based on GNSS observation
NASA Astrophysics Data System (ADS)
Husin, A.; Jiyo; Anggarani, S.; Ekawati, S.; Dear, V.
2016-11-01
A total solar eclipse occurred over Indonesia in the morning hours on 9 March 2016. Ionisations in the ionosphere which is associated with the solar radiation during the total eclipse provided a good opportunity to study the ionospheric irregularities. Using global navigation satellite system (GNSS) data taken from dual-frequency receivers in Manado, we investigated and analysed the total electron content (TEC) perturbations with a time resolution of 60 s to reveal ionospheric irregularities during total eclipse. Result showed that TEC conditions based on IPP were decreased during solar eclipse on March 9, comparing with the neighbour day. The maximum percentage deviation (DTEC) from the average value during eclipse period, 00:00 - 02:40 UT reach -41.5%. The duration of maximum decrement in TEC occurs were around 2-30 minutes after the maximum obscuration.
Structure and absolute configuration of some 5-chloro-2-methoxy-N-phenylbenzamide derivatives
NASA Astrophysics Data System (ADS)
Galal, Alaaeldin M. F.; Shalaby, Elsayed M.; Abouelsayed, Ahmed; Ibrahim, Medhat A.; Al-Ashkar, Emad; Hanna, Atef G.
2018-01-01
The absolute configuration of 5-chloro-2-methoxy-N-phenylbenzamide single crystal [compound (1)] and the effect of introducing -[CH2]n-, n = 1,2 group adjacent to the amide group [compounds (2) and (3)], were studied. Furthermore, the replacement of the methoxy group with a hydroxy group [compound (4)] was defined. Proton and carbon-13 NMR spectrometer were used to record the structural information of the prepared compounds. X-ray single crystal diffractometer were used to elucidate the 3D structural configurations. Intensity data for the studied compounds were collected at room temperature. The X-ray data prove that compound (1) is almost planar, with maximum r.m.s. deviations of 0.210(3) Å corresponds to C13. This planarity starts to disturb by adding -[CH2]n-, n = 1,2 groups between the NH group and the phenyl ring in compounds (2) and (3), respectively. By replacing the OCH3 group by an OH group in compound (4), the plane of the chlorophenyl moiety is nearly perpendicular to that of the phenyl ring. Such new structural configurations were further illustrated by the infrared, and ultraviolet-visible spectroscopy measurements in the frequency range 400-4000 cm-1 and 190-1100 nm, respectively. Spectroscopic analyses were verified with the help of molecular modeling using density functional theory. The estimated total dipole moment for the prepared compounds reflects its ability to interact with its surrounding molecules. The higher dipole moment for a given structures is combined with the higher reactivity for potential use in medicinal applications.
NASA Astrophysics Data System (ADS)
Viana, Liviany; Herdies, Dirceu; Muller, Gabriela
2017-04-01
An observational study was carried out to quantify the events of cold air outbreak moving above the Equator from 1980 to 2013 during the austral winter period (May, June, July, August and September), and later analyzed the behavior of the circulation responsible for this displacement. The observational datasets from the Sector of Climatological studies of the Institute of Airspace Control of the city of Iauarete (0.61N, 69.0W; 120m), located at the extreme northern of the Brazilian Amazon Basin, were used for the analyzes. The meteorological variables used were the temperatures minimum, maximum and maximum atmospheric pressure. A new methodology was used to identify these events, calculated by the difference between the monthly average and 2 (two) standard deviations for the extremes of the air temperature, and the sum of 1 (one) standard deviation for the maximum atmospheric pressure. As a result, a total of 11 cold events were recorded that reached the extreme northern of the Brazilian Amazon Basin, with values recorded at a minimum temperature of 17.8 °C, at the maximum temperature of 21.0 °C and maximum atmospheric pressure reaching 1021.2 hPa. These reductions and augmentation are equivalent to the negative anomalies of 5.9 and 8.7 °C at the minimum and maximum temperatures, respectively, while a positive anomaly of 7.1 hPa was observed at the maximum pressure. In relation to the dynamic behavior of large-scale circulation, a Rossby wave-type configuration propagating from west to east over subtropical latitudes was observed from the European Center for Medium-Range Weather Forecast (ECMWF) since the days before the arrival of the event in the city of Iauarete. This behavior was observed both in the anomalies of the gepotencial (250 hPa and 850 hPa) and in the southern component of the wind (250 hPa and 850 hPa), both presenting statistical significance of 99 % (Student's T test). Therefore, a new criterion for the identification of "friagens" in the tropical latitude has been able to represent the effects of colds air outbreak and the advancement of the cold air mass, which are subsidized by the large-scale circulation, and consequently contribute to the modifications in the weather and the life of the population over this Equatorial region.
Ertl, Lorenz; Christ, Frank
2007-08-01
Better quality bystander first-aid could improve outcome rates for emergency victims significantly. In this case-control study, we hypothesised that expert knowledge presented step-by-step to untrained helpers using a personal digital assistant (PDA), would improve the quality of bystanders basic life support. We confronted 101 lay-helpers with two standard emergency situations. (1) An unconscious trauma victim with severe bleeding. (2) Cardiopulmonary resuscitation (CPR). Performance was assessed using an Objective Structured Clinical Examination (OSCE). One group was supported by a PDA providing visual and audio instructions, whereas the control group acted only with their current knowledge. The expert system was programmed in HTML-code and displayed on the PDA's Internet browser. The maximum score obtainable was 24 points corresponding to optimal treatment. The control group without the PDA reached 14.8+/-3.5 (mean value+/-standard deviation), whereas the PDA supported group scored significantly higher (21.9+/-2.7, p<0.01). The difference in performance was measurable in all criteria tested and particularly notable in the items: placing in recovery position, airway management and quality of CPR. The PDA based expert system increased the performance of untrained helpers supplying emergency care significantly. Since Internet compatible mobile devices have become widely available, a significant quality improvement in bystander first-aid seems possible.
Cardio-pulmonary fitness test by ultra-short heart rate variability.
Aslani, Arsalan; Aslani, Amir; Kheirkhah, Jalal; Sobhani, Vahid
2011-10-01
It is known that exercise induces cardio-respiratory autonomic modulation. The aim of this study was to assess the cardio-pulmonary fitness by ultra-short heart rate variability. Study population was divided into 3 groups: Group-1 (n = 40) consisted of military sports man. Group-2 (n = 40) were healthy age-matched sedentary male subjects with normal body mass index [BMI = 19 - 25 kg/m(2)). Group-3 (n = 40) were healthy age-matched obese male subjects [BMI > 29 kg/m(2)). Standard deviation of normal-to-normal QRS intervals (SDNN) was recorded over 15 minutes. Bruce protocol treadmill test was used; and, maximum oxygen consumption (VO(2)max) was calculated. WHEN THE STUDY POPULATION WAS DIVIDED INTO QUARTILES OF SDNN (FIRST QUARTILE: < 60 msec; second quartile: > 60 and < 100 msec; third quartile: > 100 and <140 msec; and fourth quartile: >140 msec), progressive increase was found in VO(2)max; and, SDNN was significantly linked with estimated VO(2)max. In conclusion, the results of this study demonstrate that exercise training improves cardio-respiratory autonomic function (and increases heart rate variability). Improvement in cardio-respiratory autonomic function seems to translate into a lower rate of long term mortality. Ultra-short heart rate variability is a simple cardio-pulmonary fitness test which just requires 15 minutes, and involves no exercise such as in the treadmill or cycle test.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Udrescu, Corina; Mornex, Francoise, E-mail: francoise.mornex@chu-lyon.fr; Tanguy, Ronan
2013-01-01
Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SVmore » before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.« less
NASA Technical Reports Server (NTRS)
Igarashi, M.; Ohashi, K.; Yoshihara, T.; MacDonald, S.
1989-01-01
This study examines the effectiveness of physical exercise, during a prepathology state, on locomotor balance compensation after subsequent unilateral labyrinthectomy in squirrel monkeys. An experimental group underwent 3 hr. of daily running exercise on a treadmill for 3 mo. prior to the surgery, whereas a control group was not exercised. Postoperatively, the locomotor balance function of both groups was tested for 3 mo. There was no significant difference in gait deviation counts in the acute phase of compensation. However, in the chronic compensation maintenance phase, the number of gait deviation counts was fewer in the exercise group, which showed significantly better performance stability.
Wang, Yong Tai; Vrongistinos, Konstantinos Dino; Xu, Dali
2008-08-01
The purposes of this study were to examine the consistency of wheelchair athletes' upper-limb kinematics in consecutive propulsive cycles and to investigate the relationship between the maximum angular velocities of the upper arm and forearm and the consistency of the upper-limb kinematical pattern. Eleven elite international wheelchair racers propelled their own chairs on a roller while performing maximum speeds during wheelchair propulsion. A Qualisys motion analysis system was used to film the wheelchair propulsive cycles. Six reflective markers placed on the right shoulder, elbow, wrist joints, metacarpal, wheel axis, and wheel were automatically digitized. The deviations in cycle time, upper-arm and forearm angles, and angular velocities among these propulsive cycles were analyzed. The results demonstrated that in the consecutive cycles of wheelchair propulsion the increased maximum angular velocity may lead to increased variability in the upper-limb angular kinematics. It is speculated that this increased variability may be important for the distribution of load on different upper-extremity muscles to avoid the fatigue during wheelchair racing.
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups
Bala, Madhu; Goyal, Virender
2014-01-01
ABSTRACT Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton’s ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. Aim: To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton’s study. Materials and methods: After measuring the teeth on all 100 patients, Bolton’s analysis was performed. Results were compared with Bolton’s means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85. PMID:25356005
Lee, Eun-Young; Jun, Sul-Gi; Wright, Robert F.
2015-01-01
PURPOSE To compare the shear bond strength of various veneering materials to grade II commercially pure titanium (CP-Ti). MATERIALS AND METHODS Thirty specimens of CP-Ti disc with 9 mm diameter and 10 mm height were divided into three experimental groups. Each group was bonded to heat-polymerized acrylic resin (Lucitone 199), porcelain (Triceram), and indirect composite (Sinfony) with 7 mm diameter and 2 mm height. For the control group (n=10), Lucitone 199 were applied on type IV gold alloy castings. All samples were thermocycled for 5000 cycles in 5-55℃ water. The maximum shear bond strength (MPa) was measured with a Universal Testing Machine. After the shear bond strength test, the failure mode was assessed with an optic microscope and a scanning electron microscope. Statistical analysis was carried out with a Kruskal-Wallis Test and Mann-Whitney Test. RESULTS The mean shear bond strength and standard deviations for experimental groups were as follows: Ti-Lucitone 199 (12.11 ± 4.44 MPa); Ti-Triceram (11.09 ± 1.66 MPa); Ti-Sinfony (4.32 ± 0.64 MPa). All of these experimental groups showed lower shear bond strength than the control group (16.14 ± 1.89 MPa). However, there was no statistically significant difference between the Ti-Lucitone 199 group and the control group, and the Ti-Lucitone 199 group and the Ti-Triceram group. Most of the failure patterns in all experimental groups were adhesive failures. CONCLUSION The shear bond strength of veneering materials such as heat-polymerized acrylic resin, porcelain, and indirect composite to CP-Ti was compatible to that of heatpolymerized acrylic resin to cast gold alloy. PMID:25722841
Ramírez-Vélez, Robinson; Tordecilla-Sanders, Alejandra; Téllez-T, Luis Andrés; Camelo-Prieto, Diana; Hernández-Quiñonez, Paula Andrea; Correa-Bautista, Jorge Enrique; Garcia-Hermoso, Antonio; Ramírez-Campillo, Rodrigo; Izquierdo, Mikel
2017-02-01
We investigated the effect of moderate versus high-intensity interval exercise training on the HRV indices in physically inactive adults. Twenty inactive adults were randomly allocated to receive either moderate intensity training (MCT group) or high-intensity interval training (HIT group). The MCT group performed aerobic training at an intensity of 55-75%, which consisted of walking on a treadmill at 60-80% of the maximum heart rate (HRmax) until the expenditure of 300 kcal. The HIT group ran on a treadmill for 4 minutes at 85-95% peak HRmax and had a recovery of 4 minutes at 65% peak HRmax until the expenditure of 300 kcal. Supine resting HRV indices (time domain: SDNN, standard deviation of normal-to-normal intervals; rMSSD, Root mean square successive difference of RR intervals and frequency domain: HFLn, high-frequency spectral power; LF, low-frequency spectral power and HF/LF ratio) were measured at baseline and 12 weeks thereafter. The SDNN changes were 3.4 (8.9) ms in the MCT group and 29.1 (7.6) ms in the HIT group (difference between groups 32.6 [95% CI, 24.9 to 40.4 (P = 0.01)]. The LF/HFLn ratio change 0.19 (0.03) ms in the MCT group and 0.13 (0.01) ms in the HIT group (P between groups = 0.016). No significant group differences were observed for the rMSSD, HF and LF parameters. In inactive adults, this study showed that a 12-week HIT training program could increase short-term HRV, mostly in vagally mediated indices such as SDNN and HF/LFLn ratio power.
Mazzoni, Simona; Marchetti, Claudio; Sgarzani, Rossella; Cipriani, Riccardo; Scotti, Roberto; Ciocca, Leonardo
2013-06-01
The aim of the present study was to evaluate the accuracy of prosthetically guided maxillofacial surgery in reconstructing the mandible with a free vascularized flap using custom-made bone plates and a surgical guide to cut the mandible and fibula. The surgical protocol was applied in a study group of seven consecutive mandibular-reconstructed patients who were compared with a control group treated using the standard preplating technique on stereolithographic models (indirect computer-aided design/computer-aided manufacturing method). The precision of both surgical techniques (prosthetically guided maxillofacial surgery and indirect computer-aided design/computer-aided manufacturing procedure) was evaluated by comparing preoperative and postoperative computed tomographic data and assessment of specific landmarks. With regard to midline deviation, no significant difference was documented between the test and control groups. With regard to mandibular angle shift, only one left angle shift on the lateral plane showed a statistically significant difference between the groups. With regard to angular deviation of the body axis, the data showed a significant difference in the arch deviation. All patients in the control group registered greater than 8 degrees of deviation, determining a facial contracture of the external profile at the lower margin of the mandible. With regard to condylar position, the postoperative condylar position was better in the test group than in the control group, although no significant difference was detected. The new protocol for mandibular reconstruction using computer-aided design/computer-aided manufacturing prosthetically guided maxillofacial surgery to construct custom-made guides and plates may represent a viable method of reproducing the patient's anatomical contour, giving the surgeon better procedural control and reducing procedure time. Therapeutic, III.
[Effect strength variation in the single group pre-post study design: a critical review].
Maier-Riehle, B; Zwingmann, C
2000-08-01
In Germany, studies in rehabilitation research--in particular evaluation studies and examinations of quality of outcome--have so far mostly been executed according to the uncontrolled one-group pre-post design. Assessment of outcome is usually made by comparing the pre- and post-treatment means of the outcome variables. The pre-post differences are checked, and in case of significance, the results are increasingly presented in form of effect sizes. For this reason, this contribution presents different effect size indices used for the one-group pre-post design--in spite of fundamental doubts which exist in relation to that design due to its limited internal validity. The numerator concerning all effect size indices of the one-group pre-post design is defined as difference between the pre- and post-treatment means, whereas there are different possibilities and recommendations with regard to the denominator and hence the standard deviation that serves as the basis for standardizing the difference of the means. Used above all are standardization oriented towards the standard deviation of the pre-treatment scores, standardization oriented towards the pooled standard deviation of the pre- and post-treatment scores, and standardization oriented towards the standard deviation of the pre-post differences. Two examples are given to demonstrate that the different modes of calculating effect size indices in the one-group pre-post design may lead to very different outcome patterns. Additionally, it is pointed out that effect sizes from the uncontrolled one-group pre-post design generally tend to be higher than effect sizes from studies conducted with control groups. Finally, the pros and cons of the different effect size indices are discussed and recommendations are given.
Estimating extreme stream temperatures by the standard deviate method
NASA Astrophysics Data System (ADS)
Bogan, Travis; Othmer, Jonathan; Mohseni, Omid; Stefan, Heinz
2006-02-01
It is now widely accepted that global climate warming is taking place on the earth. Among many other effects, a rise in air temperatures is expected to increase stream temperatures indefinitely. However, due to evaporative cooling, stream temperatures do not increase linearly with increasing air temperatures indefinitely. Within the anticipated bounds of climate warming, extreme stream temperatures may therefore not rise substantially. With this concept in mind, past extreme temperatures measured at 720 USGS stream gauging stations were analyzed by the standard deviate method. In this method the highest stream temperatures are expressed as the mean temperature of a measured partial maximum stream temperature series plus its standard deviation multiplied by a factor KE (standard deviate). Various KE-values were explored; values of KE larger than 8 were found physically unreasonable. It is concluded that the value of KE should be in the range from 7 to 8. A unit error in estimating KE translates into a typical stream temperature error of about 0.5 °C. Using a logistic model for the stream temperature/air temperature relationship, a one degree error in air temperature gives a typical error of 0.16 °C in stream temperature. With a projected error in the enveloping standard deviate dKE=1.0 (range 0.5-1.5) and an error in projected high air temperature d Ta=2 °C (range 0-4 °C), the total projected stream temperature error is estimated as d Ts=0.8 °C.
Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F
2014-08-01
To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.
Kim, Ko Eun; Jeoung, Jin Wook; Park, Ki Ho; Kim, Dong Myung; Kim, Seok Hwan
2015-03-01
To investigate the rate and associated factors of false-positive diagnostic classification of ganglion cell analysis (GCA) and retinal nerve fiber layer (RNFL) maps, and characteristic false-positive patterns on optical coherence tomography (OCT) deviation maps. Prospective, cross-sectional study. A total of 104 healthy eyes of 104 normal participants. All participants underwent peripapillary and macular spectral-domain (Cirrus-HD, Carl Zeiss Meditec Inc, Dublin, CA) OCT scans. False-positive diagnostic classification was defined as yellow or red color-coded areas for GCA and RNFL maps. Univariate and multivariate logistic regression analyses were used to determine associated factors. Eyes with abnormal OCT deviation maps were categorized on the basis of the shape and location of abnormal color-coded area. Differences in clinical characteristics among the subgroups were compared. (1) The rate and associated factors of false-positive OCT maps; (2) patterns of false-positive, color-coded areas on the GCA deviation map and associated clinical characteristics. Of the 104 healthy eyes, 42 (40.4%) and 32 (30.8%) showed abnormal diagnostic classifications on any of the GCA and RNFL maps, respectively. Multivariate analysis revealed that false-positive GCA diagnostic classification was associated with longer axial length and larger fovea-disc angle, whereas longer axial length and smaller disc area were associated with abnormal RNFL maps. Eyes with abnormal GCA deviation map were categorized as group A (donut-shaped round area around the inner annulus), group B (island-like isolated area), and group C (diffuse, circular area with an irregular inner margin in either). The axial length showed a significant increasing trend from group A to C (P=0.001), and likewise, the refractive error was more myopic in group C than in groups A (P=0.015) and B (P=0.014). Group C had thinner average ganglion cell-inner plexiform layer thickness compared with other groups (group A=B>C, P=0.004). Abnormal OCT diagnostic classification should be interpreted with caution, especially in eyes with long axial lengths, large fovea-disc angles, and small optic discs. Our findings suggest that the characteristic patterns of OCT deviation map can provide useful clues to distinguish glaucomatous changes from false-positive findings. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Validation of Fourier analysis of videokeratographic data.
Sideroudi, Haris; Labiris, Georgios; Ditzel, Fienke; Tsaragli, Efi; Georgatzoglou, Kimonas; Siganos, Haralampos; Kozobolis, Vassilios
2017-06-15
The aim was to assess the repeatability of Fourier transfom analysis of videokeratographic data using Pentacam in normal (CG), keratoconic (KC) and post-CXL (CXL) corneas. This was a prospective, clinic-based, observational study. One randomly selected eye from all study participants was included in the analysis: 62 normal eyes (CG group), 33 keratoconus eyes (KC group), while 34 eyes, which had already received CXL treatment, formed the CXL group. Fourier analysis of keratometric data were obtained using Pentacam, by two different operators within each of two sessions. Precision, repeatability and Intraclass Correlation Coefficient (ICC), were calculated for evaluating intrassesion and intersession repeatability for the following parameters: Spherical Component (SphRmin, SphEcc), Maximum Decentration (Max Dec), Regular Astigmatism, and Irregularitiy (Irr). Bland-Altman analysis was used for assessing interobserver repeatability. All parameters were presented to be repeatable, reliable and reproductible in all groups. Best intrasession and intersession repeatability and reliability were detected for parameters SphRmin, SphEcc and Max Dec parameters for both operators using ICC (intrasession: ICC > 98%, intersession: ICC > 94.7%) and within subject standard deviation. Best precision and lowest range of agreement was found for the SphRmin parameter (CG: 0.05, KC: 0.16, and CXL: 0.2) in all groups, while the lowest repeatability, reliability and reproducibility was detected for the Irr parameter. The Pentacam system provides accurate measurements of Fourier tranform keratometric data. A single Pentacam scan will be sufficient for most clinical applications.
Examining the Impact of Video Modeling Techniques on the Efficacy of Clinical Voice Assessment.
Werner, Cara; Bowyer, Samantha; Weinrich, Barbara; Gottliebson, Renee; Brehm, Susan Baker
2017-01-01
The purpose of the current study was to determine whether or not presenting patients with a video model improves efficacy of the assessment as defined by efficiency and decreased variability in trials during the acoustic component of voice evaluations. Twenty pediatric participants with a mean age of 7.6 years (SD = 1.50; range = 6-11 years), 32 college-age participants with a mean age of 21.32 years (SD = 1.61; range = 18-30 years), and 17 adult participants with a mean age of 54.29 years (SD = 2.78; range = 50-70 years) were included in the study and divided into experimental and control groups. The experimental group viewed a training video prior to receiving verbal instructions and performing acoustic assessment tasks, whereas the control group received verbal instruction only prior to completing the acoustic assessment. Primary measures included the number of clinician cues required and instructional time. Standard deviations of acoustic measurements (eg, minimum and maximum frequency) were also examined to determine effects on stability. Individuals in the experimental group required significantly less cues, P = 0.012, compared to the control group. Although some trends were observed in instructional time and stability of measurements, no significant differences were observed. The findings of this study may be useful for speech-language pathologists in regard to improving assessment of patients' voice disorders with the use of video modeling. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Xiaobo, Feng; Jianjuan, Ke; Yanlin, Wang
2012-01-01
This study was designed to compare the variability of the onset and offset of the effect of two neuromuscular blocking drugs with different elimination pathways in adult and elderly patients during total intravenous anesthesia (TIVA). After Ethics Committee approval and patients' informed consent, the drugs were compared in 40 adult and 40 elderly patients scheduled for elective surgery under TIVA with tracheal intubation who were randomized to receive a single bolus dose of 0.15 mg/kg cisatracurium or 0.9 mg/kg rocuronium. The time of onset of maximum depression, duration of action, and recovery index time were measured and recorded for each patient and variability is reported as means ± standard deviation. Time of onset was significantly shorter for rocuronium than cisatracurium for the adult and elderly groups (P = 0.000), but the variability of cisatracurium was significantly greater compared with rocuronium for the same age groups (93.25 vs 37.01 s in the adult group and 64.56 vs 33.75 s in the elderly group; P = 0.000). The duration of the effect in the elderly group receiving rocuronium was significantly longer than in the elderly group receiving cisatracurium, and the variability of the duration was significantly greater in the rocuronium group than in the cisatracurium group. Mean time of recovery was significantly longer for the elderly group receiving rocuronium than for the elderly group receiving cisatracurium (P = 0.022), and variability was also greater (P = 0.002). Both drugs favored good intubating conditions. In conclusion, cisatracurium showed less variability in these parameters than rocuronium, especially in the elderly, a fact that may be of particular clinical interest. PMID:22584638
Nodera, Minoru; Suzuki, Hitoshi; Yamada, Shinya; Kamioka, Masashi; Kaneshiro, Takashi; Kamiyama, Yoshiyuki; Takeishi, Yasuchika
2015-01-01
Several studies have demonstrated that oral intake of n-3 polyunsaturated fatty acids, specifically eicosapentaenoic acid (EPA), prevents ventricular tachyarrhythmias (VT) with ischemic heart disease, but the underlying mechanisms still remain unclear. Thus, we examined the relation between the serum EPA/arachidonic acid (AA) ratio and electrophysiological properties in patients with ischemic heart disease. The study subjects consisted of 57 patients (46 males, mean age, 66 ± 13 years) with ischemic heart disease. T-wave alternans (TWA) and heart rate variability were assessed by 24hour Holter ECG, and left ventricular ejection fraction (LVEF) was determined by echocardiography. Fasting blood samples were collected, and the serum EPA/AA ratio was determined. Based on a median value of the serum EPA/AA ratio, all subjects were divided into two groups: serum EPA/AA ratio below 0.33 (Group-L, n = 28) or not (Group-H, n = 29). We compared these parameters between the two groups. LVEF was not different between the two groups. The maximum value of TWA was significantly higher in Group-L than in Group-H (69.5 ± 22.8 μV versus 48.7 ± 12.0 μV, P = 0.007). In addition, VT defined as above 3 beats was observed in 7 cases (25%) in Group-L, but there were no cases of VT in Group-H (P = 0.004). However, low-frequency (LF) component, high-frequency (HF) component, LF to HF ratio, and standard deviation of all R-R intervals were not different between the two groups. These results suggest that a low EPA/AA ratio may induce cardiac electrical instability, but not autonomic nervous imbalance, associated with VT in patients with ischemic heart disease.
Identification of Dynapenia in Older Adults Through the Use of Grip Strength T-Scores
Bohannon, Richard W; Magasi, Susan
2014-01-01
Objective To generate reference values and t-scores (1.0 to 2.5 standard deviations below average) for grip strength for healthy young adults and to examine the utility of t-scores from this group for the identification of dynapenia in older adults. Design Secondary analysis of cross-sectional grip strength data from the NIH Toolbox norming sample. Setting Population-based general community sample. Participants Community dwelling adults, between the ages 20 and 40 years (n=558); and 60 to 85 years (n=390) Main Outcomes Measures Grip strength measured with a Jamar plus dynamometer. Results Maximum grip strengths were consistent over the 20–40 year age span. For men they were 108.0 lbs (S.D. 22.6). For women, they were 65.8 lbs (S.D. 14.6) Comparison of older participant grip strengths to those of the younger reference group revealed (depending on age strata) that 46.2–87.1% of older men and 50.0–82.4% of older women could be designated as dynapenic on the basis of t-scores. Conclusion The use of reference value t-scores from younger adults is a promising method for determining dynapenia in older adults. PMID:24729356
Radiotherapy in pediatric medulloblastoma: Quality assessment of Pediatric Oncology Group Trial 9031
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miralbell, Raymond; Fitzgerald, T.J.; Laurie, Fran
2006-04-01
Purpose: To evaluate the potential influence of radiotherapy quality on survival in high-risk pediatric medulloblastoma patients. Methods and Materials: Trial 9031 of the Pediatric Oncology Group (POG) aimed to study the relative benefit of cisplatin and etoposide randomization of high-risk patients with medulloblastoma to preradiotherapy vs. postradiotherapy treatment. Two-hundred and ten patients were treated according to protocol guidelines and were eligible for the present analysis. Treatment volume (whole brain, spine, posterior fossa, and primary tumor bed) and dose prescription deviations were assessed for each patient. An analysis of first site of failure was undertaken. Event-free and overall survival rates weremore » calculated. A log-rank test was used to determine the significance of potential survival differences between patients with and without major deviations in the radiotherapy procedure. Results: Of 160 patients who were fully evaluable for all treatment quality parameters, 91 (57%) had 1 or more major deviations in their treatment schedule. Major deviations by treatment site were brain (26%), spinal (7%), posterior fossa (40%), and primary tumor bed (17%). Major treatment volume or total dose deviations did not significantly influence overall and event-free survival. Conclusions: Despite major treatment deviations in more than half of fully evaluable patients, underdosage or treatment volume misses were not associated with a worse event-free or overall survival.« less
Saha, Arjun; Raghavachari, Krishnan
2015-05-12
We have investigated the performance of two classes of fragmentation methods developed in our group (Molecules-in-Molecules (MIM) and Many-Overlapping-Body (MOB) expansion), to reproduce the unfragmented MP2 energies on a test set composed of 10 small to large biomolecules. They have also been assessed to recover the relative energies of different motifs of the acetyl(ala)18NH2 system. Performance of different bond-cutting environments and the use of Hartree-Fock and different density functionals (as a low level of theory) in conjunction with the fragmentation strategies have been analyzed. Our investigation shows that while a low level of theory (for recovering long-range interactions) may not be necessary for small peptides, it provides a very effective strategy to accurately reproduce the total and relative energies of larger peptides such as the different motifs of the acetyl(ala)18NH2 system. Employing M06-2X as the low level of theory, the calculated mean total energy deviation (maximum deviation) in the total MP2 energies for the 10 molecules in the test set at MIM(d=3.5Å), MIM(η=9), and MOB(d=5Å) are 1.16 (2.31), 0.72 (1.87), and 0.43 (2.02) kcal/mol, respectively. The excellent performance suggests that such fragment-based methods should be of general use for the computation of accurate energies of large biomolecular systems.
Ives, Rachel; Humphrey, Louise
2017-05-01
Studies of male and female long bone growth in past populations are limited and usually constrained by the lack of personal identification. This article aimed to evaluate long bone growth in a series of mid-19 th century documented burials associated with the urban poor from Bethnal Green, London, UK. Maximum diaphyseal lengths from 74 males and 70 females (2 months to 12 years) were compared to modern reference data from North America. Diaphyseal lengths were expressed as a percentage of expected length and an average percentage value was calculated across all available long bones. An index of growth progression was introduced to explore differences in the progress of males and females towards their projected adult size. Deviation from the expected growth attainment was evident in both sexes in the archaeological series by 2-4 months of age. Only 19.4% (28/144) of the children had attained an average long bone length >90% of the predicted mean in the reference series. The percentage of expected growth attainment decreased steadily in both sexes during infancy and early childhood. Overall, females deviated further from their expected growth progression than males. Growth faltering in both males and females was established during infancy (<1 year) with no evidence for recovery in older age groups. Early weaning and inadequate artificial feeding, together with impoverished living conditions and limited sanitary provision, most likely impacted on childhood growth. © 2017 Wiley Periodicals, Inc.
Cochlear implanted children present vocal parameters within normal standards.
de Souza, Lourdes Bernadete Rocha; Bevilacqua, Maria Cecília; Brasolotto, Alcione Ghedini; Coelho, Ana Cristina
2012-08-01
to compare acoustic and perceptual parameters regarding the voice of cochlear implanted children, with normal hearing children. this is a cross-sectional, quantitative and qualitative study. Thirty six cochlear implanted children aged between 3 y and 3 m to 5 y and 9 m and 25 children with normal hearing, aged between 3 y and 11 m and 6 y and 6 m, participated in this study. The recordings and the acoustics analysis of the sustained vowel/a/and spontaneous speech were performed using the PRAAT program. The parameters analyzed for the sustained vowel were the mean of the fundamental frequency, jitter, shimmer and harmonic-to-noise ratio (HNR). For the spontaneous speech, the minimum and maximum frequencies and the number of semitones were extracted. The perceptual analysis of the speech material was analyzed using visual-analogical scales of 100 points, composing the aspects related to the overall severity of the vocal deviation, roughness, breathiness, strain, pitch, loudness and resonance deviation, and instability. This last parameter was only analyzed for the sustained vowel. The results demonstrated that the majority of the vocal parameters analyzed in the samples of the implanted children disclosed values similar to those obtained by the group of children with normal hearing. implanted children who participate in a (re) habilitation and follow-up program, can present vocal characteristics similar to those vocal characteristics of children with normal hearing. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Kumar, M Praveen; Patil, Suneel G; Dheeraj, Bhandari; Reddy, Keshav; Goel, Dinker; Krishna, Gopi
2015-06-01
The difficulty in obtaining an acceptable impression increases exponentially as the number of abutments increases. Accuracy of the impression material and the use of a suitable impression technique are of utmost importance in the fabrication of a fixed partial denture. This study compared the accuracy of the matrix impression system with conventional putty reline and multiple mix technique for individual dies by comparing the inter-abutment distance in the casts obtained from the impressions. Three groups, 10 impressions each with three impression techniques (matrix impression system, putty reline technique and multiple mix technique) were made of a master die. Typodont teeth were embedded in a maxillary frasaco model base. The left first premolar was removed to create a three-unit fixed partial denture situation and the left canine and second premolar were prepared conservatively, and hatch marks were made on the abutment teeth. The final casts obtained from the impressions were examined under a profile projector and the inter-abutment distance was calculated for all the casts and compared. The results from this study showed that in the mesiodistal dimensions the percentage deviation from master model in Group I was 0.1 and 0.2, in Group II was 0.9 and 0.3, and Group III was 1.6 and 1.5, respectively. In the labio-palatal dimensions the percentage deviation from master model in Group I was 0.01 and 0.4, Group II was 1.9 and 1.3, and Group III was 2.2 and 2.0, respectively. In the cervico-incisal dimensions the percentage deviation from the master model in Group I was 1.1 and 0.2, Group II was 3.9 and 1.7, and Group III was 1.9 and 3.0, respectively. In the inter-abutment dimension of dies, percentage deviation from master model in Group I was 0.1, Group II was 0.6, and Group III was 1.0. The matrix impression system showed more accuracy of reproduction for individual dies when compared with putty reline technique and multiple mix technique in all the three directions, as well as the inter-abutment distance.
Photorefractive InGaAs/GaAs multiple quantum wells in the Franz{endash}Keldysh geometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iwamoto, S.; Kageshima, H.; Yuasa, T.
2001-06-01
We fabricate semi-insulating InGaAs/GaAs multiple quantum wells and observe the excitonic enhancement of the photorefractivity in the Franz{endash}Keldysh geometry at wavelengths of 0.92{endash}0.94 {mu}m. A maximum two-wave mixing gain of 138 cm{sup {minus}1} and a maximum diffraction efficiency of 1.5{times}10{sup {minus}4} are obtained. The saturation intensity and the spatial resolution are also measured by four-wave mixing. The diffraction efficiency is saturated at a high external electric field. The dominant cause of this saturation is the deviation of the excitonic electroabsorption from its quadratic law. {copyright} 2001 American Institute of Physics.
Analysis of the Three-Dimensional Vector FAÇADE Model Created from Photogrammetric Data
NASA Astrophysics Data System (ADS)
Kamnev, I. S.; Seredovich, V. A.
2017-12-01
The results of the accuracy assessment analysis for creation of a three-dimensional vector model of building façade are described. In the framework of the analysis, analytical comparison of three-dimensional vector façade models created by photogrammetric and terrestrial laser scanning data has been done. The three-dimensional model built from TLS point clouds was taken as the reference one. In the course of the experiment, the three-dimensional model to be analyzed was superimposed on the reference one, the coordinates were measured and deviations between the same model points were determined. The accuracy estimation of the three-dimensional model obtained by using non-metric digital camera images was carried out. Identified façade surface areas with the maximum deviations were revealed.
Aguiar, Carlos M; Câmara, Andréa C
2008-12-01
This study evaluated, by means of the radiography examination, the occurrence of deviations in the apical third of root canals shaped with hand and rotary instruments. Sixty mandibular human molars were divided into three groups. The root canals in group 1 were instrumented with ProTaper (Dentsply/Maillefer, Ballaigues, Switzerland) for hand use, group 2 with ProTaper and group 3 with RaCe. The images obtained by double superimposition of the pre- and postoperative radiographs were evaluated by two endodontists with the aid of a magnifier-viewer and a fivefold magnifier. Statistical analysis was performed using the Fisher-Freeman-Halton. The instrumentation using the ProTaper for hand use showed 25% of the canals with a deviation in the apical third, as did the ProTaper, while the corresponding figure for the RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) was 20%, but these results were not statistically significant. There was no correlation between the occurrence of deviations in the apical third and the systems used.
[Strabismus surgery in Grave's disease--dose-effect relationships and functional results].
Schittkowski, M; Fichter, N; Guthoff, R
2004-11-01
Strabismus in thyroid ophthalmopathy is based on a loss of the contractility and distensibility of the external ocular muscles. Different therapeutic approaches are available, such as recession after pre-. or intraoperative measurement, adjustable sutures, antagonist resection, or contralateral synergist faden-operation. 26 patients with strabismus in thyroid ophthalmopathy were operated between 2000 and 2003. All patients were examined preoperatively, then 1 day and 3 - 6 months (maximum 36 months) postoperatively. Before proceeding with surgery, we waited at least 6 months after stabilization of ocular alignment and normalization of thyroid chemistry. Preoperative vertical deviation was 10-44 PD (mean 22), 3 months postoperatively it was 2-10 PD (mean 1.5). Recession of the fibrotic muscle leads to reproducible results: 3.98 +/- 0.52 PD vertical deviation/mm for the inferior rectus. In the case of a large preoperative deviation a correction should be expected, which might not be sufficient in the first few days or weeks; a second operation should not be carried out before 3 months. 7 patients were operated twice, 1 patient need three operations. 4 patients (preop. 0) achieved no double vision at all; 15 patients (preop. 1) had no double vision in the primary and reading positions; 3 patients (preop. 0) had no double vision with a maximum of 5 PD; 1 patient (preop. 7) had double vision in the primary or reading position even with prisms; and 2 patients (preop. 17) had double vision in every position. We advocate that recession of the restricted inferior or internal rectus muscle is precise, safe and effective in patients with thyroid ophthalmopathy. The recessed muscle should be fixed directly at the sclera to avoid late over-correction through a slipped muscle. The success rate in terms of binocular single vision was 76 % and 88 % with prisms added.
Non-parametric characterization of long-term rainfall time series
NASA Astrophysics Data System (ADS)
Tiwari, Harinarayan; Pandey, Brij Kishor
2018-03-01
The statistical study of rainfall time series is one of the approaches for efficient hydrological system design. Identifying, and characterizing long-term rainfall time series could aid in improving hydrological systems forecasting. In the present study, eventual statistics was applied for the long-term (1851-2006) rainfall time series under seven meteorological regions of India. Linear trend analysis was carried out using Mann-Kendall test for the observed rainfall series. The observed trend using the above-mentioned approach has been ascertained using the innovative trend analysis method. Innovative trend analysis has been found to be a strong tool to detect the general trend of rainfall time series. Sequential Mann-Kendall test has also been carried out to examine nonlinear trends of the series. The partial sum of cumulative deviation test is also found to be suitable to detect the nonlinear trend. Innovative trend analysis, sequential Mann-Kendall test and partial cumulative deviation test have potential to detect the general as well as nonlinear trend for the rainfall time series. Annual rainfall analysis suggests that the maximum changes in mean rainfall is 11.53% for West Peninsular India, whereas the maximum fall in mean rainfall is 7.8% for the North Mountainous Indian region. The innovative trend analysis method is also capable of finding the number of change point available in the time series. Additionally, we have performed von Neumann ratio test and cumulative deviation test to estimate the departure from homogeneity. Singular spectrum analysis has been applied in this study to evaluate the order of departure from homogeneity in the rainfall time series. Monsoon season (JS) of North Mountainous India and West Peninsular India zones has higher departure from homogeneity and singular spectrum analysis shows the results to be in coherence with the same.
Flethøj, Mette; Kanters, Jørgen K; Pedersen, Philip J; Haugaard, Maria M; Carstensen, Helena; Olsen, Lisbeth H; Buhl, Rikke
2016-11-28
Although premature beats are a matter of concern in horses, the interpretation of equine ECG recordings is complicated by a lack of standardized analysis criteria and a limited knowledge of the normal beat-to-beat variation of equine cardiac rhythm. The purpose of this study was to determine the appropriate threshold levels of maximum acceptable deviation of RR intervals in equine ECG analysis, and to evaluate a novel two-step timing algorithm by quantifying the frequency of arrhythmias in a cohort of healthy adult endurance horses. Beat-to-beat variation differed considerably with heart rate (HR), and an adaptable model consisting of three different HR ranges with separate threshold levels of maximum acceptable RR deviation was consequently defined. For resting HRs <60 beats/min (bpm) the threshold level of RR deviation was set at 20%, for HRs in the intermediate range between 60 and 100 bpm the threshold was 10%, and for exercising HRs >100 bpm, the threshold level was 4%. Supraventricular premature beats represented the most prevalent arrhythmia category with varying frequencies in seven horses at rest (median 7, range 2-86) and six horses during exercise (median 2, range 1-24). Beat-to-beat variation of equine cardiac rhythm varies according to HR, and threshold levels in equine ECG analysis should be adjusted accordingly. Standardization of the analysis criteria will enable comparisons of studies and follow-up examinations of patients. A small number of supraventricular premature beats appears to be a normal finding in endurance horses. Further studies are required to validate the findings and determine the clinical significance of premature beats in horses.
Leandro, G; Rolando, N; Gallus, G; Rolles, K; Burroughs, A
2005-01-01
Background: Monitoring clinical interventions is an increasing requirement in current clinical practice. The standard CUSUM (cumulative sum) charts are used for this purpose. However, they are difficult to use in terms of identifying the point at which outcomes begin to be outside recommended limits. Objective: To assess the Bernoulli CUSUM chart that permits not only a 100% inspection rate, but also the setting of average expected outcomes, maximum deviations from these, and false positive rates for the alarm signal to trigger. Methods: As a working example this study used 674 consecutive first liver transplant recipients. The expected one year mortality set at 24% from the European Liver Transplant Registry average. A standard CUSUM was compared with Bernoulli CUSUM: the control value mortality was therefore 24%, maximum accepted mortality 30%, and average number of observations to signal was 500—that is, likelihood of false positive alarm was 1:500. Results: The standard CUSUM showed an initial descending curve (nadir at patient 215) then progressively ascended indicating better performance. The Bernoulli CUSUM gave three alarm signals initially, with easily recognised breaks in the curve. There were no alarms signals after patient 143 indicating satisfactory performance within the criteria set. Conclusions: The Bernoulli CUSUM is more easily interpretable graphically and is more suitable for monitoring outcomes than the standard CUSUM chart. It only requires three parameters to be set to monitor any clinical intervention: the average expected outcome, the maximum deviation from this, and the rate of false positive alarm triggers. PMID:16210461
Hendel, Michael D; Bryan, Jason A; Barsoum, Wael K; Rodriguez, Eric J; Brems, John J; Evans, Peter J; Iannotti, Joseph P
2012-12-05
Glenoid component malposition for anatomic shoulder replacement may result in complications. The purpose of this study was to define the efficacy of a new surgical method to place the glenoid component. Thirty-one patients were randomized for glenoid component placement with use of either novel three-dimensional computed tomographic scan planning software combined with patient-specific instrumentation (the glenoid positioning system group), or conventional computed tomographic scan, preoperative planning, and surgical technique, utilizing instruments provided by the implant manufacturer (the standard surgical group). The desired position of the component was determined preoperatively. Postoperatively, a computed tomographic scan was used to define and compare the actual implant location with the preoperative plan. In the standard surgical group, the average preoperative glenoid retroversion was -11.3° (range, -39° to 17°). In the glenoid positioning system group, the average glenoid retroversion was -14.8° (range, -27° to 7°). When the standard surgical group was compared with the glenoid positioning system group, patient-specific instrumentation technology significantly decreased (p < 0.05) the average deviation of implant position for inclination and medial-lateral offset. Overall, the average deviation in version was 6.9° in the standard surgical group and 4.3° in the glenoid positioning system group. The average deviation in inclination was 11.6° in the standard surgical group and 2.9° in the glenoid positioning system group. The greatest benefit of patient-specific instrumentation was observed in patients with retroversion in excess of 16°; the average deviation was 10° in the standard surgical group and 1.2° in the glenoid positioning system group (p < 0.001). Preoperative planning and patient-specific instrumentation use resulted in a significant improvement in the selection and use of the optimal type of implant and a significant reduction in the frequency of malpositioned glenoid implants. Novel three-dimensional preoperative planning, coupled with patient and implant-specific instrumentation, allows the surgeon to better define the preoperative pathology, select the optimal implant design and location, and then accurately execute the plan at the time of surgery.
Baptayev, Bakhytzhan; Adilov, Salimgerey
2018-01-01
The whole mol-ecule of the title porphyrin, C 46 H 32 N 6 O 4 ·2C 6 H 5 NO 2 , which crystallized as a nitro-benzene disolvate, is generated by inversion symmetry. The porphyrin macrocycle is almost planar, the maximum deviation from the mean plane of the non-hydrogen atoms is 0.097 (2) Å. The aryl rings at the meso positions are inclined to this mean plane by 74.84 (6)° for the nitro-phenyl rings and 73.37 (7)° for the tolyl rings. In the crystal, the porphyrin mol-ecules are linked by C-H⋯O hydrogen bonds, forming chains along [100]. The solvent mol-ecules are also linked by C-H⋯O hydrogen bonds, forming chains along [100]. Inter-digitation of the p -tolyl groups along the c axis creates rectangular channels in which the solvent mol-ecules are located.
Kobluk, C N; Schnurr, D; Horney, F D; Sumner-Smith, G; Willoughby, R A; Dekleer, V; Hearn, T C
1989-01-01
High-speed cinematography with computer aided analysis was used to study equine hindlimb kinematics. Eight horses were filmed at the trot or the pace. Filming was done from the side (lateral) and the back (caudal). Parameters measured from the lateral filming included the heights of the tuber coxae and tailhead, protraction and retraction of the hoof and angular changes of the tarsus and stifle. Abduction and adduction of the limb and tarsal height changes were measured from the caudal filming. The maximum and minimum values plus the standard deviations and coefficients of variations are presented in tabular form. Three gait diagrams were constructed to represent stifle angle versus tarsal angle, metatarsophalangeal height versus protraction-retraction (fetlock height diagram) and tuber coxae and tailhead height versus stride (pelvic height diagram). Application of the technique to the group of horses revealed good repeatability of the gait diagrams within a limb and the diagrams appeared to be sensitive indicators of left/right asymmetries.
Lower-extremity biomechanics during forward and lateral stepping activities in older adults
Wang, Man-Ying; Flanagan, Sean; Song, Joo-Eun; Greendale, Gail A.; Salem, George J.
2012-01-01
Objective To characterize the lower-extremity biomechanics associated with stepping activities in older adults. Design Repeated-measures comparison of kinematics and kinetics associated with forward step-up and lateral step-up activities. Background Biomechanical analysis may be used to assess the effectiveness of various ‘in-home activities’ in targeting appropriate muscle groups and preserving functional strength and power in elders. Methods Data were analyzed from 21 participants (mean 74.7 yr (standard deviation, 4.4 yr)) who performed the forward and lateral step-up activities while instrumented for biomechanical analysis. Motion analysis equipment, inverse dynamics equations, and repeated measures anovas were used to contrast the maximum joint angles, peak net joint moments, angular impulse, work, and power associated with the activities. Results The lateral step-up resulted in greater maximum knee flexion (P < 0.001) and ankle dorsiflexion angles (P < 0.01). Peak joint moments were similar between exercises. The forward step-up generated greater peak hip power (P < 0.05) and total work (P < 0.001); whereas, the lateral step-up generated greater impulse (P < 0.05), work (P < 0.01), and power (P < 0.05) at the knee and ankle. Conclusions In older adults, the forward step-up places greater demand on the hip extensors, while lateral step-up places greater demand on the knee extensors and ankle plantar flexors. PMID:12620784
A possible solution to the B → π π puzzle using the principle of maximum conformality
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiao, Cong -Feng; Zhu, Rui -Lin; Wu, Xing
2015-07-22
We measured the B d→π 0π 0B d→π 0π 0 branching fraction and found that it deviates significantly from conventional QCD predictions, a puzzle which has persisted for more than 10 years. This may be a hint of new physics beyond the Standard Model; however, as we shall show in this paper, the pQCD prediction is highly sensitive to the choice of the renormalization scales which enter the decay amplitude. In the present paper, we show that the renormalization scale uncertainties for B→ππB→ππ can be greatly reduced by applying the Principle of Maximum Conformality (PMC), and more precise predictions formore » CP-averaged branching ratios B(B→ππ)B(B→ππ) can be achieved. Combining the errors in quadrature, we obtain View the MathML sourceB(Bd→π 0π 0)|PMC=(0.98 -0.31 +0.44)×10 -6 by using the light-front holographic low-energy model for the running coupling. All of the CP-averaged B→ππB→ππ branching fractions predicted by the PMC are consistent with the Particle Data Group average values and the recent Belle data. Moreover, the PMC provides a possible solution for the B d→π 0π 0B d→π 0π 0 puzzle.« less
Chen, Huan-qing; Wen, Xi-le; Li, Yang-ming; Wen, Cong-you
2015-06-01
To compare clinical effect of T-shaped locking internal fixation and external fixation in treating dorsal Barton's fracture,and investigate selective strategy of internal fixation. From January 2008 to January 2013, 100 patients with dorsal Barton's fracture were randomly divided into two groups. In treatment group, there were 30 males and 20 females with an average age of (33.8±3.6) years old;30 cases were type B, 20 cases were type C;and treated with T-shaped locking internal fixation. In control group, there were 32 male and 18 females with an average age of (32.9±3.4) years old; 29 cases were type B, 21 cases were type C; and treated with external fixation. Volar tilt, ulnar deviation and radial height at 3 months after operation were detected and compared between two groups. Mechara functional evaluation were used to evaluate postoperative clinical effects. Clinical cure time, postoperative complications,joint mobility and function score were recorded and compared between two groups. In treatment group,volar tilt was (11.9±2.7)°, ulnar deviation was (20.8+ 2.9)°,and radial height was (10.9±1.8) mm; while volar tilt was (9.1±1.6)°, ulnar deviation was (17.1±2.9)°, and radial height was (8.1±1.5) mm in control group. Treatment group was better than control group in volar tilt, ulnar deviation and radial height. Clinical cure time in treatment group was(12.0±2.3) weeks, shorter than control group (18.0±4.1) weeks. The incidence of complications in treatment group was lower than control group. According to Mehara functional evaluation,20 cases got excellent results, 25 good, 3 moderate and 2 poor in treatment group; 16 cases got excellent results, 14 good, 10 moderate and 10 poor in control group. Treatment group was better than control group in clinical effects. T-shaped locking internal fixation with postoperative functional exercise for the treatment of dorsal Barton's fracture fits for biomechanics demands,and has advantages of stable fixation,rapid recovery, less complications and good functional recovery, it has better clinical effects.
López-Tarjuelo, Juan; Bouché-Babiloni, Ana; Morillo-Macías, Virginia; Santos-Serra, Agustín; Ferrer-Albiach, Carlos
2017-01-01
To estimate angular response deviation of MOSFETs in the realm of intraoperative electron radiotherapy (IOERT), review their energy dependence, and propose unambiguous names for detector rotations. MOSFETs have been used in IOERT. Movement of the detector, namely rotations, can spoil results. We propose yaw, pitch, and roll to name the three possible rotations in space, as these unequivocally name aircraft rotations. Reinforced mobile MOSFETs (model TN-502RDM-H) and an Elekta Precise linear accelerator were used. Two detectors were placed in air for the angular response study and the whole set of five detectors was calibrated as usual to evaluate energy dependence. The maximum readout was obtained with a roll of 90° and 4 MeV. With regard to pitch movement, a substantial drop in readout was achieved at 90°. Significant overresponse was measured at 315° with 4 MeV and at 45° with 15 MeV. Energy response is not different for the following groups of energies: 4, 6, and 9 MeV; and 12 MeV, 15 MeV, and 18 MeV. Our proposal to name MOSFET rotations solves the problem of defining sensor orientations. Angular response could explain lower than expected results when the tip of the detector is lifted due to inadvertent movements. MOSFETs energy response is independent of several energies and differs by a maximum of 3.4% when dependent. This can limit dosimetry errors and makes it possible to calibrate the detectors only once for each group of energies, which saves time and optimizes lifespan of MOSFETs.
Results of module electrical measurement of the DOE 46-kilowatt procurement
NASA Technical Reports Server (NTRS)
Curtis, H. B.
1978-01-01
Current-voltage measurements have been made on terrestrial solar cell modules of the DOE/JPL Low Cost Silicon Solar Array procurement. Data on short circuit current, open circuit voltage, and maximum power for the four types of modules are presented in normalized form, showing distribution of the measured values. Standard deviations from the mean values are also given. Tests of the statistical significance of the data are discussed.
Sensitivity of Runway Occupancy Time (ROT) to Various Rollout and Turnoff (ROTO) Factors. Volume 1
NASA Technical Reports Server (NTRS)
Goldthorpe, S. H.
1997-01-01
The Terminal Area Productivity (TAP) research program was initiated by NASA to increase the airport capacity for transport aircraft operations. One element of the research program is called Low Visibility Landing and Surface Operations (LVLASO). A goal of the LVLASO research is to develop transport aircraft technologies which reduce Runway Occupancy Time (ROT) so that it does not become the limiting factor in the terminal area operations that determine the capacity of a runway. Under LVLASO, the objective of this study was to determine the sensitivity of ROT to various factors associated with the Rollout and Turnoff (ROTO) operation for transport aircraft. The following operational factors were studied and are listed in the order of decreasing ROT sensitivity: ice/flood runway surface condition, exit entrance ground speed, number of exits, high-speed exit locations and spacing, aircraft type, touchdown ground speed standard deviation, reverse thrust and braking method, accurate exit prediction capability, maximum reverse thrust availability, spiral-arc vs. circle-arc exit geometry, dry/slush/wet/snow runway surface condition, maximum allowed deceleration, auto asymmetric braking on exit, do not stow reverse thrust before the exit, touchdown longitudinal location standard deviation, flap setting, anti-skid efficiency, crosswind conditions, stopping on the exit and touchdown lateral offset.
NASA Technical Reports Server (NTRS)
Goldthorpe, S. H.
1997-01-01
The Terminal Area Productivity (TAP) research program was initiated by NASA to increase the airport capacity for transport aircraft operations. One element of the research program is called Low Visibility Landing and Surface Operations (LVLASO). A goal of the LVLASO research is to develop transport aircraft technologies which reduce Runway Occupancy Time (ROT) so that it does not become the limiting factor in the terminal area operations that determine the capacity of a runway. Under LVLASO, the objective of this study was to determine the sensitivity of ROT to various factors associated with the Rollout and Turnoff (ROTO) operation for transport aircraft. The following operational factors were studied and are listed in the order of decreasing ROT sensitivity: ice/flood runway surface condition, exit entrance ground speed, number of exits, high-speed exit locations and spacing, aircraft type, touchdown ground speed standard deviation, reverse thrust and braking method, accurate exit prediction capability, maximum reverse thrust availability, spiral-arc vs. circle-arc exit geometry, dry/slush/wet/snow runway surface condition, maximum allowed deceleration, auto asymmetric braking on exit, do not stow reverse thrust before the exit, touchdown longitudinal location standard deviation, flap setting, anti-skid efficiency, crosswind conditions, stopping on the exit and touchdown lateral offset.
Li, Minmin; Liu, Xingang; Dong, Fengshou; Xu, Jun; Qin, Dongmei; Zheng, Yongquan
2012-10-01
A new, highly sensitive, and selective method was developed for the determination of the cyflumetofen residue in water, soil, and fruits by using gas chromatography quadruple mass spectrometry. The target compound was extracted using acetonitrile and then cleaned up using dispersive solid-phase extraction with primary and secondary amine and graphitized carbon black, and optionally by a freezing-out cleanup step. The matrix-matched standards gave satisfactory recoveries and relative standard deviation values in different matrices at three fortified levels (0.05, 0.5, and 1.0 mg kg(-1) ). The overall average recoveries for this method in water, soil, and all fruits matrix at three fortified levels ranged from 76.3 to 101.5% with relative standard deviations in the range of 1.2-11.8% (n = 5). The calculated limits of detection and quantification were typically below 0.005 and 0.015 μg kg(-1), which were much lower than the maximum residue levels established by Japanese Positive List. This study provides a theoretical basis for China to draw up maximum residue level and analytical method for cyflumetofen acaricide in different fruits. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jacobsen, Svein; Stauffer, Paul R
2007-02-21
The total thermal dose that can be delivered during hyperthermia treatments is frequently limited by temperature heterogeneities in the heated tissue volume. Reliable temperature information on the heated area is thus vital for the optimization of clinical dosimetry. Microwave radiometry has been proposed as an accurate, quick and painless temperature sensing technique for biological tissue. Advantages include the ability to sense volume-averaged temperatures from subsurface tissue non-invasively, rather than with a limited set of point measurements typical of implanted temperature probes. We present a procedure to estimate the maximum tissue temperature from a single radiometric brightness temperature which is based on a numerical simulation of 3D tissue temperature distributions induced by microwave heating at 915 MHz. The temperature retrieval scheme is evaluated against errors arising from unknown variations in thermal, electromagnetic and design model parameters. Whereas realistic deviations from base values of dielectric and thermal parameters have only marginal impact on performance, pronounced deviations in estimated maximum tissue temperature are observed for unanticipated variations of the temperature or thickness of the bolus compartment. The need to pay particular attention to these latter applicator construction parameters in future clinical implementation of the thermometric method is emphasized.
Optimization of a Diaphragm for a Micro-Shock Tube-Based Drug Delivery Method
Rathod, Vivek T.; Mahapatra, Debiprosad Roy
2017-01-01
This paper presents the design optimization of diaphragms for a micro-shock tube-based drug delivery device. The function of the diaphragm is to impart the required velocity and direction to the loosely held drug particles on the diaphragm through van der Waals interaction. The finite element model-based studies involved diaphragms made up of copper, brass and aluminium. The study of the influence of material and geometric parameters serves as a vital tool in optimizing the magnitude and direction of velocity distribution on the diaphragm surface. Experiments carried out using a micro-shock tube validate the final deformed shape of the diaphragms determined from the finite element simulation. The diaphragm yields a maximum velocity of 335 m/s for which the maximum deviation of the velocity vector is 0.62°. Drug particles that travel to the destination target tissue are simulated using the estimated velocity distribution and angular deviation. Further, a theoretical model of penetration helps in the prediction of the drug particle penetration in the skin tissue like a target, which is found to be 0.126 mm. The design and calibration procedure of a micro-shock tube device to alter drug particle penetration considering the skin thickness and property are presented. PMID:28952503
NASA Astrophysics Data System (ADS)
Jacobsen, Svein; Stauffer, Paul R.
2007-02-01
The total thermal dose that can be delivered during hyperthermia treatments is frequently limited by temperature heterogeneities in the heated tissue volume. Reliable temperature information on the heated area is thus vital for the optimization of clinical dosimetry. Microwave radiometry has been proposed as an accurate, quick and painless temperature sensing technique for biological tissue. Advantages include the ability to sense volume-averaged temperatures from subsurface tissue non-invasively, rather than with a limited set of point measurements typical of implanted temperature probes. We present a procedure to estimate the maximum tissue temperature from a single radiometric brightness temperature which is based on a numerical simulation of 3D tissue temperature distributions induced by microwave heating at 915 MHz. The temperature retrieval scheme is evaluated against errors arising from unknown variations in thermal, electromagnetic and design model parameters. Whereas realistic deviations from base values of dielectric and thermal parameters have only marginal impact on performance, pronounced deviations in estimated maximum tissue temperature are observed for unanticipated variations of the temperature or thickness of the bolus compartment. The need to pay particular attention to these latter applicator construction parameters in future clinical implementation of the thermometric method is emphasized.
Yang, Pan; Peng, Yulan; Zhao, Haina; Luo, Honghao; Jin, Ya; He, Yushuang
2015-01-01
Static shear wave elastography (SWE) is used to detect breast lesions, but slice and plane selections result in discrepancies. To evaluate the intraobserver reproducibility of continuous SWE, and whether quantitative elasticities in orthogonal planes perform better in the differential diagnosis of breast lesions. One hundred and twenty-two breast lesions scheduled for ultrasound-guided biopsy were recruited. Continuous SWE scans were conducted in orthogonal planes separately. Quantitative elasticities and histopathology results were collected. Reproducibility in the same plane and diagnostic performance in different planes were evaluated. The maximum and mean elasticities of the hardest portion, and standard deviation of whole lesion, had high inter-class correlation coefficients (0.87 to 0.95) and large areas under receiver operation characteristic curve (0.887 to 0.899). Without loss of accuracy, sensitivities had increased in orthogonal planes compared with single plane (from 73.17% up to 82.93% at most). Mean elasticity of whole lesion and lesion-to-parenchyma ratio were significantly less reproducible and less accurate. Continuous SWE is highly reproducible for the same observer. The maximum and mean elasticities of the hardest portion and standard deviation of whole lesion are most reliable. Furthermore, the sensitivities of the three parameters are improved in orthogonal planes without loss of accuracies.
NASA Astrophysics Data System (ADS)
Wang, J.; Shi, M.; Zheng, P.; Xue, Sh.; Peng, R.
2018-03-01
Laser-induced breakdown spectroscopy has been applied for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens Maxim. f. biserrata Shan et Yuan used in traditional Chinese medicine. Ca II 317.993 nm, Mg I 517.268 nm, and K I 769.896 nm spectral lines have been chosen to set up calibration models for the analysis using the external standard and artificial neural network methods. The linear correlation coefficients of the predicted concentrations versus the standard concentrations of six samples determined by the artificial neural network method are 0.9896, 0.9945, and 0.9911 for Ca, Mg, and K, respectively, which are better than for the external standard method. The artificial neural network method also gives better performance comparing with the external standard method for the average and maximum relative errors, average relative standard deviations, and most maximum relative standard deviations of the predicted concentrations of Ca, Mg, and K in the six samples. Finally, it is proved that the artificial neural network method gives better performance compared to the external standard method for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens.
Choi, Joon Young; Yang, Jaewon; Noworolski, Susan M; Behr, Spencer; Chang, Albert J; Simko, Jeffry P; Nguyen, Hao G; Carroll, Peter R; Kurhanewicz, John; Seo, Youngho
2017-02-01
Purpose To investigate the initial clinical value of fluorine 18 ( 18 F) fluorocholine (FCH) dynamic positron emission tomography (PET)/magnetic resonance (MR) imaging by comparing its parameters with clinical-pathologic findings in patients with newly diagnosed intermediate- to high-risk prostate cancer (PCa) who plan to undergo radical prostatectomy. Materials and Methods The institutional review board approved the study protocol, and informed written consent was obtained from all subjects for this HIPAA-compliant study. Twelve men (mean age ± standard deviation, 61.7 years ± 8.4; range, 46-74 years) with untreated intermediate- to high-risk PCa characterized according to Cancer of the Prostate Risk Assessment (CAPRA) underwent preoperative FCH dynamic PET/MR imaging followed by radical prostatectomy between April and November 2015. PET/MR imaging parameters including average and maximum K1 (delivery rate constant) and standardized uptake values (SUVs) and Prostate Imaging Reporting and Data System (PI-RADS) version 2 scores were measured and compared with clinical-pathologic characteristics. For statistical analysis, the Spearman rank correlation and Mann-Whitney U tests were performed. Results Of the PET parameters, maximum SUV of primary tumors showed significant correlations with several clinical-pathologic parameters including serum prostate-specific antigen level (ρ = 0.71, P = .01), pathologic stage (ρ = 0.59, P = .043), and postsurgical CAPRA score (ρ = 0.72, P = .008). The overall PI-RADS score showed significant correlations with pathologic tumor volume (ρ = 0.81, P < .001), percentage of tumor cells with Gleason scores greater than 3 (ρ = 0.59, P = .02), and postsurgical CAPRA score (ρ = 0.58, P = .046). The high-risk postsurgical CAPRA score patient group had a significantly higher maximum SUV than did the intermediate-risk group. Combined PET and MR imaging showed improved sensitivity (88%) for prediction of pathologic extraprostatic extension compared with that with MR imaging (50%) and PET (75%) performed separately. Conclusion Maximum SUVs and PI-RADS scores from FCH PET/MR imaging show good correlation with clinical-pathologic characteristics, such as postsurgical CAPRA score, which are related to prognosis in patients with newly diagnosed intermediate- to high-risk PCa. © RSNA, 2016 Online supplemental material is available for this article.
Liu, Jinbao; Han, Jichang; Zhang, Yang; Wang, Huanyuan; Kong, Hui; Shi, Lei
2018-06-05
The storage of soil organic carbon (SOC) should improve soil fertility. Conventional determination of SOC is expensive and tedious. Visible-near infrared reflectance spectroscopy is a practical and cost-effective approach that has been successfully used SOC concentration. Soil spectral inversion model could quickly and efficiently determine SOC content. This paper presents a study dealing with SOC estimation through the combination of soil spectroscopy and stepwise multiple linear regression (SMLR), partial least squares regression (PLSR), principal component regression (PCR). Spectral measurements for 106 soil samples were acquired using an ASD FieldSpec 4 standard-res spectroradiometer (350-2500 nm). Six types of transformations and three regression methods were applied to build for the quantification of different parent materials development soil. The results show that (1)the basaltic volcanic clastics development of SOC spectral response bands located in 500 nm, 800 nm; Trachyte spectral response of the soil quality, and the volcanic clastics development at 405 nm, 465 nm, 575 nm, 1105 nm. (2) Basaltic volcanic debris soil development, first deviation of maximum correlation coefficient is 0.8898; thick surface soil of the development of rocky volcanic debris from bottom reflectivity logarithm of first deviation of maximum correlation coefficient is 0.9029. (3) Soil organic matter content of basaltic volcanic clastics development optimal prediction model based on spectral reflectance inverse logarithms of first deviation of SMLR. Independent variable number is 7, Rv 2 = 0.9720, RMSEP = 2.0590, sig = 0.003. Trachyte qualitative volcanic clastics developed soil organic matter content of the optimal prediction model based on spectral reflectance inverse logarithms of first deviation of PLSR. Model number of the independent variables Pc = 5, Rc = 0.9872, Rc 2 = 0.9745, RMSEC = 0.4821, SEC = 0.4906, forecasts determine coefficient Rv 2 = 0.9702, RMSEP = 0.9563, SEP = 0.9711, Bias = 0.0637. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yohannes, Indra; Vasiliniuc, Stefan; Hild, Sebastian
Purpose: Five tissue- and water-equivalent materials (TEMs) mimicking ICRU real tissues have been formulated using a previously established stoichiometric analysis method (SAM) to be applied in charged particle therapy. The purpose of this study was an experimental verification of the TEMs-SAM against charged particle beam measurements and for different computed tomography (CT) scanners. The potential of the TEMs-SAM to be employed in the dosimetry was also investigated. Methods: Experimental verification with three CT scanners was carried out to validate the calculated Hounsfield units (HUs) of the TEMs. Water-equivalent path lengths (WEPLs) of the TEMs for proton (106.8 MeV/u), helium (107.93more » MeV/u), and carbon (200.3 MeV/u) ions were measured to be compared with the computed relative stopping powers. HU calibration curves were also generated. Results: Differences between the measured HUs of the TEMs and the calculated HUs of the ICRU real tissues for all CT scanners were smaller than 4 HU except for the skeletal tissues which deviated up to 21 HU. The measured WEPLs verified the calculated WEPLs of the TEMs (maximum deviation was 0.17 mm) and were in good agreement with the calculated WEPLs of the ICRU real tissues (maximum deviation was 0.23 mm). Moreover, the relative stopping powers converted from the measured WEPLs differed less than 0.8% and 1.3% from the calculated values of the SAM and the ICRU, respectively. Regarding the relative nonelastic cross section per unit of volume for 200 MeV protons, the ICRU real tissues were generally well represented by the TEMs except for adipose which differed 3.8%. Further, the HU calibration curves yielded the mean and the standard deviation of the errors not larger than 0.5% and 1.9%, respectively. Conclusions: The results of this investigation implied the potential of the TEMs formulated using the SAM to be employed for both, beam dosimetry and HU calibration in charged particle therapy.« less
NASA Astrophysics Data System (ADS)
Dessens, J.; Bücher, A.
In an attempt to contribute to the investigation on a global climate change, a historical series of minimum and maximum temperature data at the Pic du Midi, a mountain observatory at 2862 m a.s.l. in the French Pyrenees, is updated after correction of a systematic deviation due to a relocation of the station in 1971. These data, which now cover the 1882-1984 period, are examined in parallel with humidity and cloud cover data for the same period. From the beginning to the end of this period, observations show that the mean night-time temperature has increased by 2.39° C/100 yr while the mean daytime temperature has decreased by 0.50° C/100 yr. In consequence, the mean annual diurnal temperature range has dropped by 36%/100 yr. The maximum seasonal decrease is 46%/100 yr in spring. Season-to-season and year-to-year inter-relationships between minimum temperature, maximum temperature, relative humidity and cloud cover suggest that the decrease in maximum temperature is related to a concomitant increase of 15%/100 yr in both relative humidity and cloud cover.
Social deviance activates the brain's error-monitoring system.
Kim, Bo-Rin; Liss, Alison; Rao, Monica; Singer, Zachary; Compton, Rebecca J
2012-03-01
Social psychologists have long noted the tendency for human behavior to conform to social group norms. This study examined whether feedback indicating that participants had deviated from group norms would elicit a neural signal previously shown to be elicited by errors and monetary losses. While electroencephalograms were recorded, participants (N = 30) rated the attractiveness of 120 faces and received feedback giving the purported average rating made by a group of peers. The feedback was manipulated so that group ratings either were the same as a participant's rating or deviated by 1, 2, or 3 points. Feedback indicating deviance from the group norm elicited a feedback-related negativity, a brainwave signal known to be elicited by objective performance errors and losses. The results imply that the brain treats deviance from social norms as an error.
Effects of special composite stretching on the swing of amateur golf players
Lee, Joong-chul; Lee, Sung-wan; Yeo, Yun-ghi; Park, Gi Duck
2015-01-01
[Purpose] The study investigated stretching for safer a golf swing compared to present stretching methods for proper swings in order to examine the effects of stretching exercises on golf swings. [Subjects] The subjects were 20 amateur golf club members who were divided into two groups: an experimental group which performed stretching, and a control group which did not. The subjects had no bone deformity, muscle weakness, muscle soreness, or neurological problems. [Methods] A swing analyzer and a ROM measuring instrument were used as the measuring tools. The swing analyzer was a GS400-golf hit ball analyzer (Korea) and the ROM measuring instrument was a goniometer (Korea). [Results] The experimental group showed a statistically significant improvement in driving distance. After the special stretching training for golf, a statistically significant difference in hit-ball direction deviation after swings were found between the groups. The experimental group showed statistically significant decreases in hit ball direction deviation. After the special stretching training for golf, statistically significant differences in hit-ball speed were found between the groups. The experimental group showed significant increases in hit-ball speed. [Conclusion] To examine the effects of a special stretching program for golf on golf swing-related factors, 20 male amateur golf club members performed a 12-week stretching training program. After the golf stretching training, statistically significant differences were found between the groups in hit-ball driving distance, direction deviation, deflection distance, and speed. PMID:25995553
Effects of special composite stretching on the swing of amateur golf players.
Lee, Joong-Chul; Lee, Sung-Wan; Yeo, Yun-Ghi; Park, Gi Duck
2015-04-01
[Purpose] The study investigated stretching for safer a golf swing compared to present stretching methods for proper swings in order to examine the effects of stretching exercises on golf swings. [Subjects] The subjects were 20 amateur golf club members who were divided into two groups: an experimental group which performed stretching, and a control group which did not. The subjects had no bone deformity, muscle weakness, muscle soreness, or neurological problems. [Methods] A swing analyzer and a ROM measuring instrument were used as the measuring tools. The swing analyzer was a GS400-golf hit ball analyzer (Korea) and the ROM measuring instrument was a goniometer (Korea). [Results] The experimental group showed a statistically significant improvement in driving distance. After the special stretching training for golf, a statistically significant difference in hit-ball direction deviation after swings were found between the groups. The experimental group showed statistically significant decreases in hit ball direction deviation. After the special stretching training for golf, statistically significant differences in hit-ball speed were found between the groups. The experimental group showed significant increases in hit-ball speed. [Conclusion] To examine the effects of a special stretching program for golf on golf swing-related factors, 20 male amateur golf club members performed a 12-week stretching training program. After the golf stretching training, statistically significant differences were found between the groups in hit-ball driving distance, direction deviation, deflection distance, and speed.
Yatsushiro, Satoshi; Sunohara, Saeko; Hayashi, Naokazu; Hirayama, Akihiro; Matsumae, Mitsunori; Atsumi, Hideki; Kuroda, Kagayaki
2018-04-10
A correlation mapping technique delineating delay time and maximum correlation for characterizing pulsatile cerebrospinal fluid (CSF) propagation was proposed. After proofing its technical concept, this technique was applied to healthy volunteers and idiopathic normal pressure hydrocephalus (iNPH) patients. A time-resolved three dimensional-phase contrast (3D-PC) sampled the cardiac-driven CSF velocity at 32 temporal points per cardiac period at each spatial location using retrospective cardiac gating. The proposed technique visualized distributions of propagation delay and correlation coefficient of the PC-based CSF velocity waveform with reference to a waveform at a particular point in the CSF space. The delay time was obtained as the amount of time-shift, giving the maximum correlation for the velocity waveform at an arbitrary location with that at the reference location. The validity and accuracy of the technique were confirmed in a flow phantom equipped with a cardiovascular pump. The technique was then applied to evaluate the intracranial CSF motions in young, healthy (N = 13), and elderly, healthy (N = 13) volunteers and iNPH patients (N = 13). The phantom study demonstrated that root mean square error of the delay time was 2.27%, which was less than the temporal resolution of PC measurement used in this study (3.13% of a cardiac cycle). The human studies showed a significant difference (P < 0.01) in the mean correlation coefficient between the young, healthy group and the other two groups. A significant difference (P < 0.05) was also recognized in standard deviation of the correlation coefficients in intracranial CSF space among all groups. The result suggests that the CSF space compliance of iNPH patients was lower than that of healthy volunteers. The correlation mapping technique allowed us to visualize pulsatile CSF velocity wave propagations as still images. The technique may help to classify diseases related to CSF dynamics, such as iNPH.
Ionospheric reaction on sudden stratospheric warming events in Russiás Asia region
NASA Astrophysics Data System (ADS)
Polyakova, Anna; Perevalova, Natalya; Chernigovskaya, Marina
2015-12-01
The response of the ionosphere to sudden stratospheric warmings (SSWs) in the Asian region of Russia is studied. Two SSW events observed in 2008-2009 and 2012-2013 winter periods of extreme solar minimum and moderate solar maximum are considered. To detect the ionospheric effects caused by SSWs, we carried out a joint analysis of global ionospheric maps (GIM) of the total electron content (TEC), MLS (Microwave Limb Sounder, EOS Aura) measurements of temperature vertical profiles, as well as NCEP/NCAR and UKMO Reanalysis data. For the first time, it was found that during strong SSWs, in the mid-latitude ionosphere the amplitude of diurnal TEC variation decreases nearly half compared to quiet days. At the same time, the intensity of TEC deviations from the background level increases. It was also found that at SSW peak the midday TEC maximum decreases, and night/morning TEC values increase compared to quiet days. It was shown that during SSWs, TEC dynamics was identical for different geophysical conditions.The response of the ionosphere to sudden stratospheric warmings (SSWs) in the Asian region of Russia is studied. Two SSW events observed in 2008-2009 and 2012-2013 winter periods of extreme solar minimum and moderate solar maximum are considered. To detect the ionospheric effects caused by SSWs, we carried out a joint analysis of global ionospheric maps (GIM) of the total electron content (TEC), MLS (Microwave Limb Sounder, EOS Aura) measurements of temperature vertical profiles, as well as NCEP/NCAR and UKMO Reanalysis data. For the first time, it was found that during strong SSWs, in the mid-latitude ionosphere the amplitude of diurnal TEC variation decreases nearly half compared to quiet days. At the same time, the intensity of TEC deviations from the background level increases. It was also found that at SSW peak the midday TEC maximum decreases, and night/morning TEC values increase compared to quiet days. It was shown that during SSWs, TEC dynamics was identical for different geophysical conditions.
Clonidine versus nitroglycerin infusion in laparoscopic cholecystectomy.
Mishra, Manjaree; Mishra, Shashi Prakash; Mathur, Sharad Kumar
2014-01-01
Laparoscopic surgery offers the advantages of minimally invasive surgery; however, pneumoperitoneum and the patient's position induce pathophysiological changes that may complicate anesthetic management. We studied the effect of clonidine and nitroglycerin on heart rate and blood pressure, if any, in association with these drugs or the procedure, as well as the effect of these drugs, if any, on end-tidal carbon dioxide pressure and intraocular pressure. Sixty patients (minimum age of 20 years and maximum age of 65 years, American Society of Anesthesiologists class I or II) undergoing laparoscopic cholecystectomy were randomized into 3 groups and given an infusion of clonidine (group I), nitroglycerin (group II), or normal saline solution (group III) after induction and before creation of pneumoperitoneum. We observed and recorded the following parameters: heart rate, mean arterial blood pressure, end-tidal carbon dioxide pressure, and intraocular pressure. The mean and standard deviation of the parameters studied during the observation period were calculated for the 3 treatment groups and compared by use of analysis of variance tests. Intragroup comparison was performed with the paired t test. The critical value of P, indicating the probability of a significant difference, was taken as < .05 for comparisons. Statistically significant differences in heart rate were observed among the various groups, whereas comparisons of mean arterial pressure, intraocular pressure, and end-tidal carbon dioxide pressure showed statistically significant differences only between groups I and III and between groups II and III. We found clonidine to be more effective than nitroglycerin at preventing changes in hemodynamic parameters and intraocular pressure induced by carbon dioxide insufflation during laparoscopic cholecystectomy. It was also found not to cause hypotension severe enough to stop the infusion and warrant treatment.
Clonidine Versus Nitroglycerin Infusion in Laparoscopic Cholecystectomy
Mishra, Manjaree; Mishra, Shashi Prakash
2014-01-01
Background and Objectives: Laparoscopic surgery offers the advantages of minimally invasive surgery; however, pneumoperitoneum and the patient's position induce pathophysiological changes that may complicate anesthetic management. We studied the effect of clonidine and nitroglycerin on heart rate and blood pressure, if any, in association with these drugs or the procedure, as well as the effect of these drugs, if any, on end-tidal carbon dioxide pressure and intraocular pressure. Methods: Sixty patients (minimum age of 20 years and maximum age of 65 years, American Society of Anesthesiologists class I or II) undergoing laparoscopic cholecystectomy were randomized into 3 groups and given an infusion of clonidine (group I), nitroglycerin (group II), or normal saline solution (group III) after induction and before creation of pneumoperitoneum. We observed and recorded the following parameters: heart rate, mean arterial blood pressure, end-tidal carbon dioxide pressure, and intraocular pressure. The mean and standard deviation of the parameters studied during the observation period were calculated for the 3 treatment groups and compared by use of analysis of variance tests. Intragroup comparison was performed with the paired t test. The critical value of P, indicating the probability of a significant difference, was taken as < .05 for comparisons. Results: Statistically significant differences in heart rate were observed among the various groups, whereas comparisons of mean arterial pressure, intraocular pressure, and end-tidal carbon dioxide pressure showed statistically significant differences only between groups I and III and between groups II and III. Conclusion: We found clonidine to be more effective than nitroglycerin at preventing changes in hemodynamic parameters and intraocular pressure induced by carbon dioxide insufflation during laparoscopic cholecystectomy. It was also found not to cause hypotension severe enough to stop the infusion and warrant treatment. PMID:25392635
Mandibular deviations in TMD and non-TMD groups related to eye dominance and head posture.
Pradham, N S; White, G E; Mehta, N; Forgione, A
2001-01-01
This study was designed to determine whether eye-dominance affects head posture (rotation) and in turn, whether head posture is associated with mandibular frenum midline deviation, in both TMJ and control subjects. Eye dominance was determined using three tests: Porta, Hole, Point tests. Natural head posture was evaluated using the Arthrodial protractor. Mandibular frenum deviation was recorded as left, right or no deviation. Fifty female subjects were included in the study, 25 TMJ patients attending the Gelb Craniomandibular Pain Center and 25 non-TMJ control subjects. The findings indicate that eye dominance and direction of head rotation are strongly associated in both TMJ and control subjects. Further, in TMJ subjects mandibular deviation occurred in greater frequency than in controls and tends to occur in the contra lateral direction of head rotation.
Dobrakowski, Michał; Boroń, Marta; Kasperczyk, Sławomir; Kozłowska, Agnieszka; Kasperczyk, Aleksandra; Płachetka, Anna; Pawlas, Natalia
2017-06-01
The aim of the present study was to compare a group of workers with stable lead levels with a group of workers with fluctuating lead levels in terms of selected hematological, biochemical, and immunological parameters. The examined group included male workers occupationally exposed to lead. Blood lead (PbB) levels were measured every 3 months during the 5-year observation. Based on standard deviation of mean PbB levels, the examined population was divided into two groups: low level of fluctuation (L-SD) and high level of fluctuation (H-SD) groups. The mean and maximal PbB levels were significantly higher in the H-SD group than in the L-SD group by 9 and 22%, respectively. At the same time, the maximal level of zinc protoporphyrin (ZPP) and standard deviation of mean ZPP level were higher in the H-SD group by 29 and 55%, respectively. The maximal level of hemoglobin and white blood cell (WBC) count as well as standard deviation of the mean hemoglobin level and WBC count were higher in the H-SD group by 2, 8, 58, and 24%, respectively. The expression of nuclear factor kappa-B1 gene and telomerase reverse transcriptase gene was significantly greater in the H-SD group than in the L-SD group by 11 and 28%, respectively. Workers occupationally exposed to lead do not represent a homogenous population. Some present stable lead levels, whereas others have fluctuating lead levels. These fluctuations are related to secondary changes in ZPP and hemoglobin levels as well as WBC count.
Zhang, X Y; Li, H; Zhao, Y J; Wang, Y; Sun, Y C
2016-07-01
To quantitatively evaluate the quality and accuracy of three-dimensional (3D) data acquired by using two kinds of structure intra-oral scanner to scan the typical teeth crown preparations. Eight typical teeth crown preparations model were scanned 3 times with two kinds of structured light intra-oral scanner(A, B), as test group. A high precision model scanner were used to scan the model as true value group. The data above the cervical margin was extracted. The indexes of quality including non-manifold edges, the self-intersections, highly-creased edges, spikes, small components, small tunnels, small holes and the anount of triangles were measured with the tool of mesh doctor in Geomagic studio 2012. The scanned data of test group were aligned to the data of true value group. 3D deviations of the test group compared with true value group were measured for each scanned point, each preparation and each group. Independent-samples Mann-Whitney U test was applied to analyze 3D deviations for each scanned point of A and B group. Correlation analysis was applied to index values and 3D deviation values. The total number of spikes in A group was 96, and that in B group and true value group were 5 and 0 respectively. Trueness: A group 8.0 (8.3) μm, B group 9.5 (11.5) μm(P>0.05). Correlation analysis of the number of spikes with data precision of A group was r=0.46. In the study, the qulity of the scanner B is better than scanner A, the difference of accuracy is not statistically significant. There is correlation between quality and data precision of the data scanned with scanner A.
Left-Deviating Prism Adaptation in Left Neglect Patient: Reflexions on a Negative Result
Luauté, Jacques; Jacquin-Courtois, Sophie; O'Shea, Jacinta; Christophe, Laure; Rode, Gilles; Boisson, Dominique; Rossetti, Yves
2012-01-01
Adaptation to right-deviating prisms is a promising intervention for the rehabilitation of patients with left spatial neglect. In order to test the lateral specificity of prism adaptation on left neglect, the present study evaluated the effect of left-deviating prism on straight-ahead pointing movements and on several classical neuropsychological tests in a group of five right brain-damaged patients with left spatial neglect. A group of healthy subjects was also included for comparison purposes. After a single session of exposing simple manual pointing to left-deviating prisms, contrary to healthy controls, none of the patients showed a reliable change of the straight-ahead pointing movement in the dark. No significant modification of attentional paper-and-pencil tasks was either observed immediately or 2 hours after prism adaptation. These results suggest that the therapeutic effect of prism adaptation on left spatial neglect relies on a specific lateralized mechanism. Evidence for a directional effect for prism adaptation both in terms of the side of the visuomanual adaptation and therefore possibly in terms of the side of brain affected by the stimulation is discussed. PMID:23050168
Wang, Zhi-Tao; W.L. Au, Whitlow; Rendell, Luke; Wu, Hai-Ping; Wu, Yu-Ping; Liu, Jian-Chang; Duan, Guo-Qin; Cao, Han-Jiang
2016-01-01
Background. Knowledge of species-specific vocalization characteristics and their associated active communication space, the effective range over which a communication signal can be detected by a conspecific, is critical for understanding the impacts of underwater acoustic pollution, as well as other threats. Methods. We used a two-dimensional cross-shaped hydrophone array system to record the whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in shallow-water environments of the Pearl River Estuary (PRE) and Beibu Gulf (BG), China. Using hyperbolic position fixing, which exploits time differences of arrival of a signal between pairs of hydrophone receivers, we obtained source location estimates for whistles with good signal-to-noise ratio (SNR ≥10 dB) and not polluted by other sounds and back-calculated their apparent source levels (ASL). Combining with the masking levels (including simultaneous noise levels, masking tonal threshold, and the Sousa auditory threshold) and the custom made site-specific sound propagation models, we further estimated their active communication space (ACS). Results. Humpback dolphins produced whistles with average root-mean-square ASL of 138.5 ± 6.8 (mean ± standard deviation) and 137.2 ± 7.0 dB re 1 µPa in PRE (N = 33) and BG (N = 209), respectively. We found statistically significant differences in ASLs among different whistle contour types. The mean and maximum ACS of whistles were estimated to be 14.7 ± 2.6 (median ± quartile deviation) and 17.1± 3.5 m in PRE, and 34.2 ± 9.5 and 43.5 ± 12.2 m in BG. Using just the auditory threshold as the masking level produced the mean and maximum ACSat of 24.3 ± 4.8 and 35.7 ± 4.6 m for PRE, and 60.7 ± 18.1 and 74.3 ± 25.3 m for BG. The small ACSs were due to the high ambient noise level. Significant differences in ACSs were also observed among different whistle contour types. Discussion. Besides shedding some light for evaluating appropriate noise exposure levels and information for the regulation of underwater acoustic pollution, these baseline data can also be used for aiding the passive acoustic monitoring of dolphin populations, defining the boundaries of separate groups in a more biologically meaningful way during field surveys, and guiding the appropriate approach distance for local dolphin-watching boats and research boat during focal group following. PMID:26893973
Wang, Zhi-Tao; W L Au, Whitlow; Rendell, Luke; Wang, Ke-Xiong; Wu, Hai-Ping; Wu, Yu-Ping; Liu, Jian-Chang; Duan, Guo-Qin; Cao, Han-Jiang; Wang, Ding
2016-01-01
Background. Knowledge of species-specific vocalization characteristics and their associated active communication space, the effective range over which a communication signal can be detected by a conspecific, is critical for understanding the impacts of underwater acoustic pollution, as well as other threats. Methods. We used a two-dimensional cross-shaped hydrophone array system to record the whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in shallow-water environments of the Pearl River Estuary (PRE) and Beibu Gulf (BG), China. Using hyperbolic position fixing, which exploits time differences of arrival of a signal between pairs of hydrophone receivers, we obtained source location estimates for whistles with good signal-to-noise ratio (SNR ≥10 dB) and not polluted by other sounds and back-calculated their apparent source levels (ASL). Combining with the masking levels (including simultaneous noise levels, masking tonal threshold, and the Sousa auditory threshold) and the custom made site-specific sound propagation models, we further estimated their active communication space (ACS). Results. Humpback dolphins produced whistles with average root-mean-square ASL of 138.5 ± 6.8 (mean ± standard deviation) and 137.2 ± 7.0 dB re 1 µPa in PRE (N = 33) and BG (N = 209), respectively. We found statistically significant differences in ASLs among different whistle contour types. The mean and maximum ACS of whistles were estimated to be 14.7 ± 2.6 (median ± quartile deviation) and 17.1± 3.5 m in PRE, and 34.2 ± 9.5 and 43.5 ± 12.2 m in BG. Using just the auditory threshold as the masking level produced the mean and maximum ACSat of 24.3 ± 4.8 and 35.7 ± 4.6 m for PRE, and 60.7 ± 18.1 and 74.3 ± 25.3 m for BG. The small ACSs were due to the high ambient noise level. Significant differences in ACSs were also observed among different whistle contour types. Discussion. Besides shedding some light for evaluating appropriate noise exposure levels and information for the regulation of underwater acoustic pollution, these baseline data can also be used for aiding the passive acoustic monitoring of dolphin populations, defining the boundaries of separate groups in a more biologically meaningful way during field surveys, and guiding the appropriate approach distance for local dolphin-watching boats and research boat during focal group following.
Richards, Michael D; Goltz, Herbert C; Wong, Agnes M F
2018-01-01
Classically understood as a deficit in spatial vision, amblyopia is increasingly recognized to also impair audiovisual multisensory processing. Studies to date, however, have not determined whether the audiovisual abnormalities reflect a failure of multisensory integration, or an optimal strategy in the face of unisensory impairment. We use the ventriloquism effect and the maximum-likelihood estimation (MLE) model of optimal integration to investigate integration of audiovisual spatial information in amblyopia. Participants with unilateral amblyopia (n = 14; mean age 28.8 years; 7 anisometropic, 3 strabismic, 4 mixed mechanism) and visually normal controls (n = 16, mean age 29.2 years) localized brief unimodal auditory, unimodal visual, and bimodal (audiovisual) stimuli during binocular viewing using a location discrimination task. A subset of bimodal trials involved the ventriloquism effect, an illusion in which auditory and visual stimuli originating from different locations are perceived as originating from a single location. Localization precision and bias were determined by psychometric curve fitting, and the observed parameters were compared with predictions from the MLE model. Spatial localization precision was significantly reduced in the amblyopia group compared with the control group for unimodal visual, unimodal auditory, and bimodal stimuli. Analyses of localization precision and bias for bimodal stimuli showed no significant deviations from the MLE model in either the amblyopia group or the control group. Despite pervasive deficits in localization precision for visual, auditory, and audiovisual stimuli, audiovisual integration remains intact and optimal in unilateral amblyopia.
Jithesh, C; Venkataramana, V; Penumatsa, Narendravarma; Reddy, S N; Poornima, K Y; Rajasigamani, K
2015-08-01
To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P < 0.05). The descriptive method of statistics was used to calculate the mean, standard deviation, minimum and maximum. SPSS 18 software ((SPSS.Ltd, Quarry bay, Hong Kong, PASW-statistics 18) was used to analyze the study. The analysis shows a significant difference between three groups. The study shows that the nickel releases from the recycled stainless steel brackets have the highest at all 4.2 pH except in 120 h. The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable.
Jithesh, C.; Venkataramana, V.; Penumatsa, Narendravarma; Reddy, S. N.; Poornima, K. Y.; Rajasigamani, K.
2015-01-01
Objectives: To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Materials and Methods: Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P < 0.05). The descriptive method of statistics was used to calculate the mean, standard deviation, minimum and maximum. SPSS 18 software ((SPSS.Ltd, Quarry bay, Hong Kong, PASW-statistics 18) was used to analyze the study. Result: The analysis shows a significant difference between three groups. The study shows that the nickel releases from the recycled stainless steel brackets have the highest at all 4.2 pH except in 120 h. Conclusion: The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable. PMID:26538924
Zhou, Chunlüe; Wang, Kaicun
2016-05-13
Most studies on global warming rely on global mean surface temperature, whose change is jointly determined by anthropogenic greenhouse gases (GHGs) and natural variability. This introduces a heated debate on whether there is a recent warming hiatus and what caused the hiatus. Here, we presented a novel method and applied it to a 5° × 5° grid of Northern Hemisphere land for the period 1900 to 2013. Our results show that the coldest 5% of minimum temperature anomalies (the coldest deviation) have increased monotonically by 0.22 °C/decade, which reflects well the elevated anthropogenic GHG effect. The warmest 5% of maximum temperature anomalies (the warmest deviation), however, display a significant oscillation following the Atlantic Multidecadal Oscillation (AMO), with a warming rate of 0.07 °C/decade from 1900 to 2013. The warmest (0.34 °C/decade) and coldest deviations (0.25 °C/decade) increased at much higher rates over the most recent decade than last century mean values, indicating the hiatus should not be interpreted as a general slowing of climate change. The significant oscillation of the warmest deviation provides an extension of previous study reporting no pause in the hottest temperature extremes since 1979, and first uncovers its increase from 1900 to 1939 and decrease from 1940 to 1969.
French, H P; Keogan, F; Gilsenan, C; Waldron, L; O'Connell, P
2010-06-01
To assess patient satisfaction with exercise for knee osteoarthritis (OA). A convenience sample of 27 patients recruited to a randomized controlled trial (RCT) comparing open kinetic chain and closed kinetic chain exercises for knee OA were reassessed at nine months post-randomization. Clinical outcomes included self-report and physical performance measures of function and pain severity. Patients also completed the Physiotherapy Outpatient Survey (POPS), which is a multi-dimensional measure of patient satisfaction with physiotherapy. There was no significant difference in satisfaction between the two intervention groups. Overall mean satisfaction for the entire cohort was 4.07 of a maximum score of 5 (standard deviation (SD) = 0.52). Lower levels of satisfaction with outcome (mean = 3.56, SD = 0.8) were reported compared with other domains of expectations, communication, organization and the therapist (mean = 3.79-4.49; SDs = 0.42-0.92). Both intervention groups improved from baseline on clinical outcomes of pain, self-report function and walking distance, with no significant differences between the two groups. High levels of satisfaction were reported in this subsample of knee OA patients participating in an RCT evaluating the effects of different exercise approaches for knee OA. Satisfaction varied depending on the satisfaction domain, with lower satisfaction with outcome compared with other aspects of care. The POPS questionnaire can be used to measure the multi-dimensional aspects of satisfaction with physiotherapy.
Jayakumar, T; Savithri, S R
2012-01-01
Dysphonia Severity Index (DSI) is a widely used multiparametric approach to objectively quantify the voice quality. Few research groups have investigated the test-retest, interobserver variability, and influence of age and gender. They have also verified the application of DSI in various voice rehabilitation conditions. However, all these studies have been conducted on European population. There is a possibility of variation in the basic parameters of DSI across geographical and ethnic groups. Hence, the present study evaluated DSI in Indian population. One hundred twenty voluntary participants (60 males, 60 females) who had G(0) on the Grade, Roughness, Breathiness, Aesthenia, Strain (GRBAS) scale participated in the study (age range of 18-25 years, M=21.8, standard deviation=2.7). Maximum phonation time (MPT), frequency intensity, and jitter measurements were made using CSL 4500 (Kay Elemetrics, Pine Brook, NJ). Results showed noticeable difference between Indian and European population on MPT, Highest frequency (F(0)-High), and DSI values. Significant gender difference was also observed on MPT and F(0)-High. Test-retest reliability showed >95% for all the parameters. The MPT decrement lead to a reduction in the overall DSI value in both the genders. These results of the study caution voice professionals to reinvestigate and establish their own norms for their geographical and ethnic groups. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Stress Counter-Response Training Via Physiological Self-Regulation During Flight Simulation
NASA Technical Reports Server (NTRS)
Palsson, Olafur S.
2000-01-01
This study provided the first evaluation of a new training concept and technology aimed at training pilots to maintain physiological equilibrium during circumstances in an airplane cockpit. Thirty healthy subjects (16 males and 14 females) between the ages of 18 and 35 were randomized into two study groups, A and B. Subjects participated individually in a sequence of four study sessions. In the first visit, subjects were taught to operate a desktop fighter jet flight simulation program. In the three sessions that followed, subjects in group A were trained to minimize their autonomic deviation from baseline values while operating the desktop flight simulation. This was done by making their skin conductance and hand temperature deviations from baseline impair the functionality of the aircraft controls. Subjects also received auditory and visual cues about their autonomic deviation, and were instructed to keep these within pre-set limits to retain full control of the aircraft. Subjects in group B were subjected to periods of impaired aircraft functionality independent of their physiologic activity, and thus served as a control group. No statistically significant group differences were found in the flight performance scores from the three training sessions, and post-training flight performance scores of the two groups were not different. We conclude that this study did not provide clear support for this training methodology in optimizing pilot performance. However, a number of shortcomings in the current status of this training methodology may account for the lack of demonstrable training benefit to the experimental group. Suggested future modifications for research on this training methodology include: Limiting the amount of instrument impairment resulting from physiological deviations; conducting a greater number of physiological training sessions per subject; using pre-post training performance tests which invoke a greater amount of stress in subjects; and developing a more detailed performance scoring system.
Is there another major constituent in the atmosphere of Mars?. [radiogenic argon
NASA Technical Reports Server (NTRS)
Wood, G. P.
1974-01-01
In view of the possible finding of several tens percent of inert gas in the atmosphere of Mars by an instrument on the descent module of the USSR's Mars 6 spacecraft, the likelihood of the correctness of this result was examined. The basis for the well-known fact that the most likely candidate is radiogenic argon is described. It is shown that, for the two important methods of investigating the atmosphere, earth-based CO2 is infrared absorption spectroscopy and S-band occultation, within the estimated 1 standard deviation uncertainties of these methods about 20% argon can be accommodated. Within the estimated 3 standard deviation uncertainties, more than 35% is possible. It is also stated that even with 35% argon the maximum value of heat transfer rate on the Viking 75 entry vehicle does not exceed the design value.
Validation of Harris Detector and Eigen Features Detector
NASA Astrophysics Data System (ADS)
Kok, K. Y.; Rajendran, P.
2018-05-01
Harris detector is one of the most common features detection for applications such as object recognition, stereo matching and target tracking. In this paper, a similar Harris detector algorithm is written using MATLAB and the performance is compared with MATLAB built in Harris detector for validation. This is to ensure that rewritten version of Harris detector can be used for Unmanned Aerial Vehicle (UAV) application research purpose yet can be further improvised. Another corner detector close to Harris detector, which is Eigen features detector is rewritten and compared as well using same procedures with same purpose. The simulation results have shown that rewritten version for both Harris and Eigen features detectors have the same performance with MATLAB built in detectors with not more than 0.4% coordination deviation, less than 4% & 5% response deviation respectively, and maximum 3% computational cost error.
Fernandes, S M; Lima, J L; Rangel, A O
2000-01-01
A flow injection system for the automatic determination of total phosphorus in beer is described. The developed manifold uses a two-stage photooxidation/thermal digestion procedure together with oxidizing and hydrolyzing reagents to convert all forms of phosphorus compounds to orthophosphate. Polyphosphates are hydrolyzed by acid and heat, and organo-phosphates are digested by UV-catalyzed peroxodisulfate oxidation. The orthophosphate formed is then spectrophotometrically determined by the phosphomolybdenum blue reaction, using stannous chloride as reducing agent. The results obtained for a set of 19 beer samples (with concentrations from 120 to 735 mg P/L) were in good agreement with the reference method, the maximum relative deviation found being 4.7%. Relative standard deviations for ten consecutive determinations were lower than 1.5%, and a detection limit of 1 mg P/L was achieved.
Over, Thomas M.; Saito, Riki J.; Soong, David T.
2016-06-30
The observed and adjusted values for each streamgage are tabulated. To illustrate the overall effect of the adjustments, differences in the mean, standard deviation, and skewness of the log-transformed observed and urbanization-adjusted peak discharge series by streamgage are computed. For almost every streamgage where an adjustment was applied (no increase in urbanization was reported for a few streamgages), the mean increased and the standard deviation decreased; the effect on skewness values was more variable but usually they increased. Significant positive peak discharge trends were common in the observed values, occurring at 27.3 percent of streamgages at a p-value of 0.05 according to a Kendall’s tau correlation test; in the adjusted values, the incidence of such trends was reduced to 7.0 percent.
Diagnosis and constitutional and laboratory features of Korean girls referred for precocious puberty
Kim, Doosoo; Cho, Sung-Yoon; Maeng, Se-Hyun; Yi, Eun Sang; Jung, Yu Jin; Park, Sung Won; Sohn, Young Bae
2012-01-01
Purpose Precocious puberty is defined as breast development before the age of 8 years in girls. The present study aimed to reveal the diagnosis of Korean girls referred for precocious puberty and to compare the constitutional and endocrinological features among diagnosis groups. Methods The present study used a retrospective chart review of 988 Korean girls who had visited a pediatric endocrinology clinic from 2006 to 2010 for the evaluation of precocious puberty. Study groups comprised fast puberty, true precocious puberty (PP), pseudo PP, premature thelarche, and control. We determined the height standard deviation score (HSDS), weight standard deviation score (WSDS), and body mass index standard deviation score (BMISDS) of each group using the published 2007 Korean growth charts. Hormone tests were performed at our outpatient clinic. Results The PP groups comprised fast puberty (67%), premature thelarche (17%), true PP (15%), and pseudo PP (1%). Advanced bone age and levels of estradiol, basal luteinizing hormone (LH), and peak LH after gonadotropin-releasing hormone stimulation testing were significantly high in the fast puberty and true PP groups compared with the control group. HSDS, WSDS, and BMISDS were significantly higher in the true PP group than in the control group (P<0.05). Conclusion The frequent causes of PP were found to be fast puberty, true PP, and premature thelarche. Furthermore, BMISDS were significantly elevated in the true PP group. Therefore, we emphasize the need for regular follow-up of girls who are heavier or taller than others in the same age group. PMID:23300504
Velocity dependence of heavy-ion stopping below the maximum
NASA Astrophysics Data System (ADS)
Sigmund, P.; Schinner, A.
2015-01-01
In the slowing-down of heavy ions in materials, the standard description by Lindhard and Scharff assumes the electronic stopping cross section to be proportional to the projectile speed v up to close to a stopping maximum, which is related to the Thomas-Fermi speed vTF . It is well known that strict proportionality with v is rarely observed, but little is known about the systematics of observed deviations. In this study we try to identify factors that determine positive or negative curvature of stopping cross sections on the basis of experimental data and of binary stopping theory. We estimate the influence of shell structure of the target and of the equilibrium charge of the ion and comment the role of dynamic screening.
Comparative assessment of prognosis of the stop stimulus and trapezoidal rotation programs
NASA Technical Reports Server (NTRS)
Grigorova, V. K.; Popov, V. K.; Todorova, V. S.
1980-01-01
For prognosis of the diagnostic possibilities of the stop stimulus and trapezoidal rotation programs with respect to the nystagmus response, 24 healthy young persons with normal auditory and vestibular analysers were studied experimentally. The trapezoidal program more accurately reflects the function and tone balance of the vestibular system than the stop stimulus program and causes the subject no unpleasant sensations during the study. Some optimum couples, acceleration and armchair rotation rate, necessary for effective deviation of the cupuloendolymphatic system were determined. The maximum angular velocity of the slow nystagmus component was more informative than nystagmus duration. The trapezoidal program is recommended for otoneurological practice and the maximum angular velocity of the slow nystagmus component as the basic index.
Choi, Yeon-Ju; Son, Wonsoo; Park, Ki-Su
2016-01-01
Objective This study used the intradural procedural time to assess the overall technical difficulty involved in surgically clipping an unruptured middle cerebral artery (MCA) aneurysm via a pterional or superciliary approach. The clinical and radiological variables affecting the intradural procedural time were investigated, and the intradural procedural time compared between a superciliary keyhole approach and a pterional approach. Methods During a 5.5-year period, patients with a single MCA aneurysm were enrolled in this retrospective study. The selection criteria for a superciliary keyhole approach included : 1) maximum diameter of the unruptured MCA aneurysm <15 mm, 2) neck diameter of the MCA aneurysm <10 mm, and 3) aneurysm location involving the sphenoidal or horizontal segment of MCA (M1) segment and MCA bifurcation, excluding aneurysms distal to the MCA genu. Meanwhile, the control comparison group included patients with the same selection criteria as for a superciliary approach, yet who preferred a pterional approach to avoid a postoperative facial wound or due to preoperative skin trouble in the supraorbital area. To determine the variables affecting the intradural procedural time, a multiple regression analysis was performed using such data as the patient age and gender, maximum aneurysm diameter, aneurysm neck diameter, and length of the pre-aneurysm M1 segment. In addition, the intradural procedural times were compared between the superciliary and pterional patient groups, along with the other variables. Results A total of 160 patients underwent a superciliary (n=124) or pterional (n=36) approach for an unruptured MCA aneurysm. In the multiple regression analysis, an increase in the diameter of the aneurysm neck (p<0.001) was identified as a statistically significant factor increasing the intradural procedural time. A Pearson correlation analysis also showed a positive correlation (r=0.340) between the neck diameter and the intradural procedural time. When comparing the superciliary and pterional groups, no statistically significant between-group difference was found in terms of the intradural procedural time reflecting the technical difficulty (mean±standard deviation : 29.8±13.0 min versus 27.7±9.6 min). Conclusion A superciliary keyhole approach can be a useful alternative to a pterional approach for an unruptured MCA aneurysm with a maximum diameter <15 mm and neck diameter <10 mm, representing no more of a technical challenge. For both surgical approaches, the technical difficulty increases along with the neck diameter of the MCA aneurysm. PMID:27847568
20 CFR 229.49 - Adjustment of benefits under family maximum for change in family group.
Code of Federal Regulations, 2010 CFR
2010-04-01
... for change in family group. 229.49 Section 229.49 Employees' Benefits RAILROAD RETIREMENT BOARD... Overall Minimum Rate § 229.49 Adjustment of benefits under family maximum for change in family group. (a) Increase in family group. If an overall minimum rate is adjusted for the family maximum and an additional...
Feingold, Alan
2009-01-01
The use of growth-modeling analysis (GMA)--including Hierarchical Linear Models, Latent Growth Models, and General Estimating Equations--to evaluate interventions in psychology, psychiatry, and prevention science has grown rapidly over the last decade. However, an effect size associated with the difference between the trajectories of the intervention and control groups that captures the treatment effect is rarely reported. This article first reviews two classes of formulas for effect sizes associated with classical repeated-measures designs that use the standard deviation of either change scores or raw scores for the denominator. It then broadens the scope to subsume GMA, and demonstrates that the independent groups, within-subjects, pretest-posttest control-group, and GMA designs all estimate the same effect size when the standard deviation of raw scores is uniformly used. Finally, it is shown that the correct effect size for treatment efficacy in GMA--the difference between the estimated means of the two groups at end of study (determined from the coefficient for the slope difference and length of study) divided by the baseline standard deviation--is not reported in clinical trials. PMID:19271847
Wootton, J Timothy
1987-07-01
I examined age at first reproduction of 547 mammalian species to determine the influence of diet and habitat on the evolution of life-history traits. Body mass correlated positively with age at first reproduction, explaining 56% of the variance. Habitat and trophic groups deviated significantly from the allometric curve in a pattern generally consistent with predictions from r/K selection theory and its modifications. However, mammalian orders also deviated significantly from the allometric curve, and different habitat and diet groups contained different ratios of mammalian orders. When the effects of orders were removed, residual deviations did not differ among ecological groups. Adjusting for ecological differences did not eliminate the differences between orders. These results suggest that body mass (or some correlated factor) and phylogeny strongly constrain age at first reproduction. Ecological factors appear to have little effect on the evolution of age at first reproduction. Apparent differences in weight-specific ages at first reproduction within habitats and trophic groups may be the result of ecological selection of order composition in the present, rather than ecologically driven evolution of life history in the past. © 1987 The Society for the Study of Evolution.
The Effects of Internal Rotation and 14N Quadrupole Coupling in N-Methyldiacetamide
NASA Astrophysics Data System (ADS)
Kannengießer, Raphaela; Eibl, Konrad; Nguyen, Ha Vinh Lam; Stahl, Wolfgang
2015-06-01
Acetyl- and nitrogen containing substances play an important role in chemical, physical, and especially biological systems. This applies in particular for acetamides, which are structurally related to peptide bonds. In this work, N-methyldiacetamide, CH_3N(COCH_3)_2, was investigated by a combination of molecular beam Fourier transform microwave spectroscopy and quantum chemical calculations. In N-methyldiacetamide, at least three large amplitude motions are possible: (1) the internal rotation of the methyl group attached to the nitrogen atom and (2, 3) the internal rotations of both acetyl methyl groups. This leads to a rather complicated torsional fine structure of all rotational transitions with additional quadrupole hyperfine splittings caused by the 14N nucleus. Quantum chemical calculations were carried out at the MP2/6-311++G(d,p) level of theory to support the spectral assignment. Conformational analysis was performed by calculating a full potential energy surface depending on the orientation of the two acetyl groups. This yielded three stable conformers with a maximum energy difference of 35.2 kJ/mol. The spectrum of the lowest energy conformer was identified in the molecular beam. The quadrupole hyperfine structure as well as the internal rotation of two methyl groups could be assigned. For the N-methyl group and for one of the two acetyl methyl groups, barriers to internal rotation of 147 cm-1 and of 680 cm-1, respectively, were determined. The barrier of the last methyl group seems to be so high that no additional splittings could be resolved. Using the XIAM program, a global fit with a standard deviation on the order of our experimental accuracy could be achieved.
Kumar, M Praveen; Patil, Suneel G; Dheeraj, Bhandari; Reddy, Keshav; Goel, Dinker; Krishna, Gopi
2015-01-01
Background: The difficulty in obtaining an acceptable impression increases exponentially as the number of abutments increases. Accuracy of the impression material and the use of a suitable impression technique are of utmost importance in the fabrication of a fixed partial denture. This study compared the accuracy of the matrix impression system with conventional putty reline and multiple mix technique for individual dies by comparing the inter-abutment distance in the casts obtained from the impressions. Materials and Methods: Three groups, 10 impressions each with three impression techniques (matrix impression system, putty reline technique and multiple mix technique) were made of a master die. Typodont teeth were embedded in a maxillary frasaco model base. The left first premolar was removed to create a three-unit fixed partial denture situation and the left canine and second premolar were prepared conservatively, and hatch marks were made on the abutment teeth. The final casts obtained from the impressions were examined under a profile projector and the inter-abutment distance was calculated for all the casts and compared. Results: The results from this study showed that in the mesiodistal dimensions the percentage deviation from master model in Group I was 0.1 and 0.2, in Group II was 0.9 and 0.3, and Group III was 1.6 and 1.5, respectively. In the labio-palatal dimensions the percentage deviation from master model in Group I was 0.01 and 0.4, Group II was 1.9 and 1.3, and Group III was 2.2 and 2.0, respectively. In the cervico-incisal dimensions the percentage deviation from the master model in Group I was 1.1 and 0.2, Group II was 3.9 and 1.7, and Group III was 1.9 and 3.0, respectively. In the inter-abutment dimension of dies, percentage deviation from master model in Group I was 0.1, Group II was 0.6, and Group III was 1.0. Conclusion: The matrix impression system showed more accuracy of reproduction for individual dies when compared with putty reline technique and multiple mix technique in all the three directions, as well as the inter-abutment distance. PMID:26124599
Gruber, Tobias; Seichter, Wilhelm; Weber, Edwin
2010-01-01
The asymmetric unit of the title compound, C17H12O, contains two molecules, in which the fused aromatic ring systems are almost planar [maximum deviations = 0.0529 (9) and 0.0256 (9) Å]. In the crystal, aromatic π–π stacking interactions (perpendicular distance of centroids of about 3.4 Å) and strong O—H⋯O hydrogen bonds result in a helical arrangement of pyrenyl dimers. PMID:21579858
Propyl 3-oxo-2,3-dihydro-1,2-benzothia-zole-2-carboxyl-ate.
Wang, Xiang-Hui; Yang, Jian-Xin; You, Cheng-Hang; Lin, Qiang
2011-09-01
The title compound, C(11)H(11)NO(3)S, was synthesized by the reaction of benzo[d]isothia-zol-3(2H)-one with propyl carbono-chloridate in toluene. The benzoisothiazolone ring system is approximately planar with a maximum deviation from the mean plane of 0.0226 (14) Å for the N atom. Weak inter-molecular C-H⋯O hydrogen bonding occurs in the crystal structure.
4-Meth-oxy-N-(1-methyl-1H-indazol-5-yl)benzene-sulfonamide.
Chicha, Hakima; Rakib, El Mostapha; Geffken, Detlef; Saadi, Mohamed; El Ammari, Lahcen
2013-01-01
The indazole ring system [maximum deviation = 0.013 (2) Å] of the title compound, C15H15N3O3S, makes a dihedral angle of 50.11 (7)° with the benzene ring. In the crystal, cohesion is provided by C-H⋯O and N-H⋯N hydrogen bonds, which link the molecules into chains propagating along the b-axis direction.
Microheterogeneity in CH3OH/CD3OH mixture
NASA Astrophysics Data System (ADS)
Wrzeszcz, Władysław; Mazurek, Sylwester; Szostak, Roman; Tomza, Paweł; Czarnecki, Mirosław A.
2018-01-01
Recently, we demonstrated the presence of microheterogeneity in binary mixtures of unlike alcohols. [RSC Adv. 2016, 6, 37195-37202] The aim of this work was examination if this phenomenon occurs also in the mixture of very similar alcohols like CH3OH and CD3OH. Theoretical calculations suggest that the isotopic substitution in methyl group influences properties of the OH group. Hence, one can expect that this effect may lead to partial separation of CH3OH and CD3OH at a molecular level and it contributes to deviation from the ideal mixture. This work evidences that CH3OH/CD3OH mixture also deviates from the ideal one, but the extent of this deviation is much smaller as compared with the mixtures of other alcohols. It is of particular note that this deviation results mainly from the difference between the CH3 and CD3 groups, while the contribution from the OH groups is small. The structure of CH3OH/CD3OH mixture at a molecular level is similar to the structure of binary mixtures of other alcohols. The mixture is composed of the homoclusters of both alcohols and the mixed clusters. The homoclusters existing in the mixture are similar to those present in bulk alcohols. The highest population of the heteroclusters and the largest deviation from the ideal mixture were observed at equimolar mixture. Both the experimental and theoretical results reveal that in CH3OH/CD3OH mixture dominate the cyclic tetramers and larger clusters, while the population of the linear clusters is negligible. Though the extent and strength of hydrogen bonding in both alcohols are the same, the position and intensity of the 2ν(OH) band for CH3OH and CD3OH are different. We propose possible explanation of this observation.
Microheterogeneity in CH3OH/CD3OH mixture.
Wrzeszcz, Władysław; Mazurek, Sylwester; Szostak, Roman; Tomza, Paweł; Czarnecki, Mirosław A
2018-01-05
Recently, we demonstrated the presence of microheterogeneity in binary mixtures of unlike alcohols. [RSC Adv. 2016, 6, 37195-37202] The aim of this work was examination if this phenomenon occurs also in the mixture of very similar alcohols like CH 3 OH and CD 3 OH. Theoretical calculations suggest that the isotopic substitution in methyl group influences properties of the OH group. Hence, one can expect that this effect may lead to partial separation of CH 3 OH and CD 3 OH at a molecular level and it contributes to deviation from the ideal mixture. This work evidences that CH 3 OH/CD 3 OH mixture also deviates from the ideal one, but the extent of this deviation is much smaller as compared with the mixtures of other alcohols. It is of particular note that this deviation results mainly from the difference between the CH 3 and CD 3 groups, while the contribution from the OH groups is small. The structure of CH 3 OH/CD 3 OH mixture at a molecular level is similar to the structure of binary mixtures of other alcohols. The mixture is composed of the homoclusters of both alcohols and the mixed clusters. The homoclusters existing in the mixture are similar to those present in bulk alcohols. The highest population of the heteroclusters and the largest deviation from the ideal mixture were observed at equimolar mixture. Both the experimental and theoretical results reveal that in CH 3 OH/CD 3 OH mixture dominate the cyclic tetramers and larger clusters, while the population of the linear clusters is negligible. Though the extent and strength of hydrogen bonding in both alcohols are the same, the position and intensity of the 2ν(OH) band for CH 3 OH and CD 3 OH are different. We propose possible explanation of this observation. Copyright © 2017 Elsevier B.V. All rights reserved.
Kim, Dong Myung; Seo, Je Hyun; Kim, Seok Hwan; Hwang, Seung-Sik
2007-05-01
To compare the features of localized retinal nerve fiber layer (RNFL) defects between a low-teen intraocular pressure (IOP) group and a high-teen IOP group in normal-tension glaucoma (NTG) patients. Seventy-seven eyes of 77 NTG patients showing localized RNFL defects on RNFL photographs and corresponding visual filed defects at the initial visit to a glaucoma specialist were selected for this study. Patients with range of diurnal IOP within low-teen or high-teen in both eyes were included. All participants completed refraction, diurnal IOP measurement, central corneal thickness (CCT) measurement, stereoscopic disc photography, RNFL photography, and automated perimetry. On RNFL photograph, approximation of the defect to the macula (angle alpha) and width of the defects (angle beta) were measured to represent RNFL defects. The patients were divided into 2 groups according to the level of IOP. A low-teen group had highest IOP of
Crimmins, Sarah; Mo, Cecilia; Nassar, Yomna; Kopelman, Jerome N; Turan, Ozhan M
2018-01-01
This study aims to investigate the perinatal outcome of fetuses with polyhydramnios and/or accelerated growth among women with a normal oral glucose challenge test (oGCT). Singleton, nonanomalous pregnancies with an oGCT(< 130 mg/dL) at 24 to 28 weeks, who subsequently demonstrate polyhydramnios (amniotic fluid index > 24 cm or maximum vertical pocket > 8 cm) and/or accelerated growth (abdominal circumference > 95th percentile) on two-third trimester examinations were studied. Maternal demographics, delivery, and neonatal information were recorded. Cases were compared with a reference group (normal oGCT with neither abnormal third-trimester growth nor polyhydramnios). A total of 282 pregnancies were in the study group, and 663 were in the reference group. Deliveries in the study group were at a higher risk for birth weight (BW)% > 90%, standard deviation, and postpartum hemorrhage when compared with the reference group (adjusted odds ratio: 2.3-5.6). Pregnancies complicated by both polyhydramnios and accelerated fetal growth were significantly more likely to result in a BW% > 90% (odds ratio [OR]: 18.5; 95% confidence interval [CI]: 8.9-38.6) and PPH (OR: 4.2; 95% CI: 2.4-7.6). Pregnancies with normal oGCT that develop polyhydramnios and accelerated growth are at higher risk for maternal and neonatal complications. Isolated polyhydramnios without accelerated growth increases the risk for delivery complications but not neonatal morbidity. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Ramsey, Elijah W.; Nelson, G.
2005-01-01
To maximize the spectral distinctiveness (information) of the canopy reflectance, an atmospheric correction strategy was implemented to provide accurate estimates of the intrinsic reflectance from the Earth Observing 1 (EO1) satellite Hyperion sensor signal. In rendering the canopy reflectance, an estimate of optical depth derived from a measurement of downwelling irradiance was used to drive a radiative transfer simulation of atmospheric scattering and attenuation. During the atmospheric model simulation, the input whole-terrain background reflectance estimate was changed to minimize the differences between the model predicted and the observed canopy reflectance spectra at 34 sites. Lacking appropriate spectrally invariant scene targets, inclusion of the field and predicted comparison maximized the model accuracy and, thereby, the detail and precision in the canopy reflectance necessary to detect low percentage occurrences of invasive plants. After accounting for artifacts surrounding prominent absorption features from about 400nm to 1000nm, the atmospheric adjustment strategy correctly explained 99% of the observed canopy reflectance spectra variance. Separately, model simulation explained an average of 88%??9% of the observed variance in the visible and 98% ?? 1% in the near-infrared wavelengths. In the 34 model simulations, maximum differences between the observed and predicted reflectances were typically less than ?? 1% in the visible; however, maximum reflectance differences higher than ?? 1.6% (?2.3%) at more than a few wavelengths were observed at three sites. In the near-infrared wavelengths, maximum reflectance differences remained less than ??3% for 68% of the comparisons (??1 standard deviation) and less than ??6% for 95% of the comparisons (??2 standard deviation). Higher reflectance differences in the visible and near-infrared wavelengths were most likely associated with problems in the comparison, not in the model generation. ?? 2005 US Government.
SU-E-T-259: Particle Swarm Optimization in Radial Dose Function Fitting for a Novel Iodine-125 Seed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, X; Duan, J; Popple, R
2014-06-01
Purpose: To determine the coefficients of bi- and tri-exponential functions for the best fit of radial dose functions of the new iodine brachytherapy source: Iodine-125 Seed AgX-100. Methods: The particle swarm optimization (PSO) method was used to search for the coefficients of the biand tri-exponential functions that yield the best fit to data published for a few selected radial distances from the source. The coefficients were encoded into particles, and these particles move through the search space by following their local and global best-known positions. In each generation, particles were evaluated through their fitness function and their positions were changedmore » through their velocities. This procedure was repeated until the convergence criterion was met or the maximum generation was reached. All best particles were found in less than 1,500 generations. Results: For the I-125 seed AgX-100 considered as a point source, the maximum deviation from the published data is less than 2.9% for bi-exponential fitting function and 0.2% for tri-exponential fitting function. For its line source, the maximum deviation is less than 1.1% for bi-exponential fitting function and 0.08% for tri-exponential fitting function. Conclusion: PSO is a powerful method in searching coefficients for bi-exponential and tri-exponential fitting functions. The bi- and tri-exponential models of Iodine-125 seed AgX-100 point and line sources obtained with PSO optimization provide accurate analytical forms of the radial dose function. The tri-exponential fitting function is more accurate than the bi-exponential function.« less
High ambient temperature and risk of intestinal obstruction in cystic fibrosis.
Ooi, Chee Y; Jeyaruban, Christina; Lau, Jasmine; Katz, Tamarah; Matson, Angela; Bell, Scott C; Adams, Susan E; Krishnan, Usha
2016-04-01
Distal intestinal obstruction syndrome (DIOS) and constipation in cystic fibrosis (CF) are conditions associated with impaction and/or obstruction by abnormally viscid mucofaecal material within the intestinal lumen. Dehydration has been proposed as a risk factor for DIOS and constipation in CF. The study primarily aimed to determine whether warmer ambient temperature and lower rainfall are risk factors for DIOS and constipation in CF. Hospitalisations for DIOS (incomplete or complete) and/or constipation were retrospectively identified (2000-2012). Genotype, phenotype, temperatures and rainfall data (for the week preceding and season of hospitalisation) were collected. Twenty-seven DIOS (59.3% incomplete; 40.7% complete) and 44 constipation admissions were identified. All admitted patients were pancreatic insufficient. Meconium ileus was significantly more likely in DIOS than constipation (64.7% vs. 33.3%; P = 0.038) and in complete than incomplete DIOS (100% vs. 57.1%; P = 0.04). The maximum temperature of the week before DIOS admission (mean (standard deviation) = 28.0 (5.8) °C) was significantly higher than the maximum temperature of the season of admission (25.2 (3.4) °C; P = 0.002). Similarly, the maximum temperature of the week before hospitalisation for constipation (mean (standard deviation) = 27.9 (6.3) °C) was significantly warmer compared with the season of admission (24.0 (4.1) °C; P < 0.0001). There were no significant differences between levels of rainfall during the week before hospitalisation and the season of admission for both DIOS and constipation. Relatively high ambient temperature may play a role in the pathogenesis of DIOS and constipation in CF. © 2016 The Authors Journal of Paediatrics and Child Health © 2016 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Ahuja, Puneeta D; Mhaske, Sheetal P; Mishra, Gaurav; Bhardwaj, Atul; Dwivedi, Ruby; Mangalekar, Sachin B
2017-06-01
One of the common findings encountered by the clinician at the end of orthodontic treatment is the apical root resorption. Root resorption occurs to various degrees. A severe form of root resorption is characterized by shortening of root for more than 4 mm or more than one-third of the total tooth length. A low incidence rate of resorption is observed based on radiographic findings for the diagnosis of root resorption, panoramic radiography, and periapical radiography. Hence, we evaluated the accuracy of panoramic radiographic films for assessing the root resorption in comparison with the periapical films. This study included the assessment of all the cases in which pre- and post-treatment radiographs were available for analysis of the assessment of the amount of root resorption. Complete records of 80 patients were analyzed. Examination of a total of 900 teeth was done. Mean age of the patients in this study was 21 years ranging from 11 to 38 years. The majority of the patients in the present study were females. All the treatments were carried out by registered experienced orthodontists having minimum experience of more than 10 years. All the cases were divided into two study groups. Group I comprised panoramic radiographic findings, while group II consisted of periapical radiographic findings. For the measurement of crown portion, root portion, and the complete root length, magnification loops of over 100 powers with parallax correction with inbuilt grids were used. Assessment of the tooth length and the crown length was done by the same observers. All the results were analyzed by Statistical Package for the Social Sciences software version 6.0. Maximum amount of root resorption was observed in case of maxillary central incisors and canines among group I and II cases respectively. However, nonsignificant difference was obtained while comparing the mean root resorption in relation to maxillary incisors and canines among the two study groups. While comparing the overall value of root resorption among the two study groups, a significant difference was obtained. The maximum value of tooth length in both the groups was observed in cases of maxillary canines. Significant differences were observed while comparing the tooth length of various teeth among the two study groups. Among the deviated forms of root shape, dilacera-tion was the most common form of root shape detected in both the study groups. Periapical radiographs are more efficient in the assessment of the shape and resorption of the root. Thorough evaluation of periapical radiographs is necessary for detection of even minute levels of root resorption.
Annoyance evaluation and the effect of noise on the health of bus drivers.
Bruno, Portela S; Marcos, Queiroga R; Amanda, Constantini; Paulo, Zannin H T
2013-01-01
In the present study, we evaluated annoyance and the effects of noise on the health of bus drivers. For that, 200 bus drivers from a public transport company participated in a cross-sectional study. Annoyance and effects on health was measured with analog scale: Sleep quality, occurrence of tinnitus, headache, irritation, and annoyance from bus engine, traffic, and passengers. Data of age and working time of bus drivers also were obtained. For noise exposure, LA eq was evaluated in 80 buses. Statistical analysis consisted of mean, standard deviation, minimum, and maximum, Kruskal-Wallis test with post-hoc Dunn, one-way ANOVA with post-hoc Tukey and Spearman's correlation coefficient. Results indicate three groups of bus drivers (not annoyed: (N.A.), a little annoyed (L.A.) and highly annoyed (H.A.)). The group H.A. was younger and with less working time in relation to others, with a significant difference only for age. Regarding sleep quality, there was no significant difference. For results on the occurrence of tinnitus, headache and irritation after work, group H.A. had significantly higher means. Result of annoyance to the bus engine was significantly higher in H.A. than in L.A. and N.A. Annoyance to traffic and passengers, no significant differences were found, but the highest results were found for L.A., followed by H.A. and N.A. Equivalent sound pressure level in buses was above of the limit for occupational comfort. It was concluded that bus drivers has considerable level of noise annoyance and some health effects are perceived. The noise is a factor discomfort ergonomic that may cause effects on health of bus drivers. This study aims to evaluate annoyance and the effects of noise on the health of bus drivers. Cross-sectional study with buses and bus drivers. For that, 200 bus drivers from a public transport company participated in a cross-sectional study. Annoyance and effects on health was measured with analog scale: Sleep quality, occurrence of tinnitus, headache, irritation and annoyance from bus engine, traffic, and passengers. Data of age and working time of bus drivers also were obtained. For noise exposure, LA eq was evaluated in 80 buses. Statistical analysis consisted of mean, standard deviation, minimum and maximum, Kruskal-Wallis test with post-hoc Dunn, one-way ANOVA with post-hoc Tukey and Spearman's correlation coefficient. Results indicate three groups of bus drivers (N.A., a L.A. and H.A.). The group H.A. was younger and with less working time in relation to others, with a significant difference only for age. Regarding sleep quality, there was no significant difference. For results on the occurrence of tinnitus, headache and irritation after work, group H.A. had significantly higher means. Result of annoyance to the bus engine was significantly higher in H.A. than in L.A. and N.A. Annoyance to traffic and passengers, no significant differences were found, but the highest results were found for L.A., followed by H.A. and N.A. Equivalent sound pressure level in buses was above of the limit for occupational comfort. It was concluded that bus drivers has considerable level of noise annoyance and some health effects are perceived.
Use of Standard Deviations as Predictors in Models Using Large-Scale International Data Sets
ERIC Educational Resources Information Center
Austin, Bruce; French, Brian; Adesope, Olusola; Gotch, Chad
2017-01-01
Measures of variability are successfully used in predictive modeling in research areas outside of education. This study examined how standard deviations can be used to address research questions not easily addressed using traditional measures such as group means based on index variables. Student survey data were obtained from the Organisation for…
Hung, Kuo-Feng; Wang, Feng; Wang, Hao-Wei; Zhou, Wen-Jie; Huang, Wei; Wu, Yi-Qun
2017-06-01
A real-time surgical navigation system potentially increases the accuracy when used for quad-zygomatic implant placement. To evaluate the accuracy of a real-time surgical navigation system when used for quad zygomatic implant placement. Patients with severely atrophic maxillae were prospectively recruited. Four trajectories for implants were planned, and zygomatic implants were placed using a real-time surgical navigation system. The planned-placed distance deviations at entry (entry deviation)points, exit (exit deviation) points, and angle deviation of axes (angle deviation) were measured on fused operation images. The differences of all the deviations between different groups, classified based on the lengths and locations of implants, were analysed. A P value of < 0.05 indicated statistical significance. Forty zygomatic implants were placed as planned in 10 patients. The entry deviation, exit deviation and angle deviation were 1.35 ± 0.75 mm, 2.15 mm ± 0.95 mm, and 2.05 ± 1.02 degrees, respectively. The differences of all deviations were not significant, irrespective of the lengths (P = .259, .158, and .914, respectively) or locations of the placed implants (P = .698, .072, and .602, respectively). A real-time surgical navigation system used for the placement of quad zygomatic implants demonstrated a high level of accuracy with only minimal planned-placed deviations, irrespective of the lengths or locations of the implants. © 2017 Wiley Periodicals, Inc.
Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.
Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat
2016-10-01
To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.
Comparison of Accuracy Between a Conventional and Two Digital Intraoral Impression Techniques.
Malik, Junaid; Rodriguez, Jose; Weisbloom, Michael; Petridis, Haralampos
To compare the accuracy (ie, precision and trueness) of full-arch impressions fabricated using either a conventional polyvinyl siloxane (PVS) material or one of two intraoral optical scanners. Full-arch impressions of a reference model were obtained using addition silicone impression material (Aquasil Ultra; Dentsply Caulk) and two optical scanners (Trios, 3Shape, and CEREC Omnicam, Sirona). Surface matching software (Geomagic Control, 3D Systems) was used to superimpose the scans within groups to determine the mean deviations in precision and trueness (μm) between the scans, which were calculated for each group and compared statistically using one-way analysis of variance with post hoc Bonferroni (trueness) and Games-Howell (precision) tests (IBM SPSS ver 24, IBM UK). Qualitative analysis was also carried out from three-dimensional maps of differences between scans. Means and standard deviations (SD) of deviations in precision for conventional, Trios, and Omnicam groups were 21.7 (± 5.4), 49.9 (± 18.3), and 36.5 (± 11.12) μm, respectively. Means and SDs for deviations in trueness were 24.3 (± 5.7), 87.1 (± 7.9), and 80.3 (± 12.1) μm, respectively. The conventional impression showed statistically significantly improved mean precision (P < .006) and mean trueness (P < .001) compared to both digital impression procedures. There were no statistically significant differences in precision (P = .153) or trueness (P = .757) between the digital impressions. The qualitative analysis revealed local deviations along the palatal surfaces of the molars and incisal edges of the anterior teeth of < 100 μm. Conventional full-arch PVS impressions exhibited improved mean accuracy compared to two direct optical scanners. No significant differences were found between the two digital impression methods.
Mandibular kinematic changes after unilateral cross-bite with lateral shift correction.
Venancio, F; Alarcon, J A; Lenguas, L; Kassem, M; Martin, C
2014-10-01
The aim of this randomised prospective study was to evaluate the effects of slow maxillary expansion with expansion plates and Hyrax expanders on the kinematics of the mandible after cross-bite correction. Thirty children (15 boys and 15 girls), aged 7·1-11·8, with unilateral cross-bite and functional shift were divided into two groups: expansion plate (n = 15) and Hyrax expander (n = 15). Thirty children with normal occlusion (14 boys and 16 girls, aged 7·3-11·6) served as control group. The maximum vertical opening, lateral mandibular shift (from maximum vertical opening to maximum intercuspation, from rest position to maximum intercuspation and from maximum vertical opening to rest position) and lateral excursions were recorded before and 4 months after treatment. After treatment, the expansion plate group showed a greater lateral shift from rest position to maximum intercuspation than did the control group. The expansion plate patients also presented greater left/contralateral excursion than did the control group. Comparisons of changes after treatment in the cross-bite groups showed significant decreases in the lateral shift from the maximum vertical opening to maximum intercuspation and from the maximum vertical opening to rest position, a significant increase in the homolateral excursion and a significant decrease in the contralateral excursion in the Hyrax expander group, whereas no significant differences were found in the expansion plate group. In conclusion, the Hyrax expander showed better results than did the expansion plate. The Hyrax expander with acrylic occlusal covering significantly improved the mandibular lateral shift and normalised the range of lateral excursion. © 2014 John Wiley & Sons Ltd.
Pinhas, Alexander; Linderman, Rachel; Mo, Shelley; Krawitz, Brian D; Geyman, Lawrence S; Carroll, Joseph; Rosen, Richard B; Chui, Toco Y
2018-01-01
To present a method for age-matched deviation mapping in the assessment of disease-related changes to the radial peripapillary capillaries (RPCs). We reviewed 4.5x4.5mm en face peripapillary OCT-A scans of 133 healthy control eyes (133 subjects, mean 41.5 yrs, range 11-82 yrs) and 4 eyes with distinct retinal pathologies, obtained using spectral-domain optical coherence tomography angiography. Statistical analysis was performed to evaluate the impact of age on RPC perfusion densities. RPC density group mean and standard deviation maps were generated for each decade of life. Deviation maps were created for the diseased eyes based on these maps. Large peripapillary vessel (LPV; noncapillary vessel) perfusion density was also studied for impact of age. Average healthy RPC density was 42.5±1.47%. ANOVA and pairwise Tukey-Kramer tests showed that RPC density in the ≥60yr group was significantly lower compared to RPC density in all younger decades of life (p<0.01). Average healthy LPV density was 21.5±3.07%. Linear regression models indicated that LPV density decreased with age, however ANOVA and pairwise Tukey-Kramer tests did not reach statistical significance. Deviation mapping enabled us to quantitatively and visually elucidate the significance of RPC density changes in disease. It is important to consider changes that occur with aging when analyzing RPC and LPV density changes in disease. RPC density, coupled with age-matched deviation mapping techniques, represents a potentially clinically useful method in detecting changes to peripapillary perfusion in disease.
Gilliom, Robert J.; Helsel, Dennis R.
1986-01-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensored observations, for determining the best performing parameter estimation method for any particular data set. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification.
Unaltered myocilin expression in the blood of primary open angle glaucoma patients
Azad, Taif Anwar; Spaeth, George L.; Myers, Jonathan; Katz, L. Jay; Moster, Marlene; Bosley, Thomas M.
2012-01-01
Purpose To investigate the expression of the myocilin gene (MYOC) in the blood of primary open angle glaucoma (POAG) patients to determine if altered systemic expression is playing a role. Methods Patients (n=47) were eligible for inclusion if they met standard clinical criteria for POAG. Control subjects (n=27) were recruited who were free from glaucoma by examination. RNA was extracted from leukocytes of patients and controls and converted to cDNA by reverse transcriptase enzyme, and quantitative PCR was used to assess expression levels of MYOC and the house keeping gene β-globulin (HBB). The ratio of MYOC expression to HBB expression for POAG patients was compared to that of controls and to clinical characteristics of POAG patients. Results Mean gene expression values were statistically similar in POAG patients and controls for both MYOC (p≤0.55) and HBB (p≤0.48). MYOC/HBB ratios were also statistically indistinguishable between POAG patients and controls (p≤0.90). MYOC/HBB ratios were not significantly associated with age, sex, or ethnicity of patients within the POAG group. Similarly, MYOC/HBB ratios were not significantly associated with clinical parameters related to POAG severity, including maximum intraocular pressure, vertical cup-to-disk ratio, static perimetry mean deviation, or static perimetry pattern standard deviation. Conclusions MYOC expression is not altered in the blood of POAG patients, unlike MYOC expression in trabecular meshwork (TM) cultures. These results suggests that MYOC expression is not altered systemically but rather that MYOC expression may contribute to POAG pathogenesis in specific tissues such as TM. PMID:22550394
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliom, R.J.; Helsel, D.R.
1986-02-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensoredmore » observations, for determining the best performing parameter estimation method for any particular data det. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification.« less
Estimation of distributional parameters for censored trace-level water-quality data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliom, R.J.; Helsel, D.R.
1984-01-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water-sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensored observations,more » for determining the best-performing parameter estimation method for any particular data set. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least-squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification. 6 figs., 6 tabs.« less
NASA Astrophysics Data System (ADS)
Zeng, C.; Plastaras, J. P.; Tochner, Z. A.; White, B. M.; Hill-Kayser, C. E.; Hahn, S. M.; Both, S.
2015-04-01
The purpose of this study was to assess the feasibility of proton pencil beam scanning (PBS) for the treatment of mediastinal lymphoma. A group of 7 patients of varying tumor size (100-800 cc) were planned using a PBS anterior field. We investigated 17 fractions of 1.8 Gy(RBE) to deliver 30.6 Gy(RBE) to the internal target volume (ITV). Spots with σ ranging from 4 mm to 8 mm were used for all patients, while larger spots (σ = 6-16 mm) were employed for patients with motion perpendicular to the beam (⩾5 mm), based on initial 4-dimensional computed tomography (4D CT) motion evaluation. We considered volumetric repainting such that the same field would be delivered twice in each fraction. The ratio of extreme inhalation amplitude and regular tidal inhalation amplitude (free-breathing variability) was quantified as an indicator of potential irregular breathing during the scanning. Four-dimensional dose was calculated on the 4D CT scans based on the respiratory trace and beam delivery sequence, implemented by partitioning the spots into separate plans on each 4D CT phase. Four starting phases (end of inhalation, end of exhalation, middle of inhalation and middle of exhalation) were sampled for each painting and 4 energy switching times (0.5 s, 1 s, 3 s and 5 s) were tested, which resulted in 896 dose distributions for the analyzed cohort. Plan robustness was measured for the target and critical structures in terms of the percent difference between ‘delivered’ dose (4D-evaluated) and planned dose (calculated on average CT). It was found that none of the patients exhibited highly variable or chaotic breathing patterns. For all patients, the ITV D98% was degraded by <2% (standard deviations ˜ 0.1%) when averaged over the whole treatment course. For six out of seven patients, the average degradation of ITV D98% per fraction was within 5% . For one patient with motion perpendicular to the beam (⩾5 mm), the degradation of ITV D98% per fraction was up to 15%, which was mitigated to 2% by employing larger spots and repainting. Deviation of mean lung dose was at most 0.2 Gy(RBE) (less than 1% of prescribed dose, 30.6 Gy(RBE)), while the deviation of heart maximum dose and cord maximum dose could exceed 5% of the prescribed dose. No significant difference in either target coverage or normal tissue dose was observed for different energy switching times compared via two-sided Wilcoxon signed-rank tests (p < 0.05). This feasibility study demonstrates that, for mediastinal lymphoma, the impact of the interplay effect on the PBS plan robustness is minimal when volumetric repainting and/or larger spots are employed.
Comparison of estimators of standard deviation for hydrologic time series
Tasker, Gary D.; Gilroy, Edward J.
1982-01-01
Unbiasing factors as a function of serial correlation, ρ, and sample size, n for the sample standard deviation of a lag one autoregressive model were generated by random number simulation. Monte Carlo experiments were used to compare the performance of several alternative methods for estimating the standard deviation σ of a lag one autoregressive model in terms of bias, root mean square error, probability of underestimation, and expected opportunity design loss. Three methods provided estimates of σ which were much less biased but had greater mean square errors than the usual estimate of σ: s = (1/(n - 1) ∑ (xi −x¯)2)½. The three methods may be briefly characterized as (1) a method using a maximum likelihood estimate of the unbiasing factor, (2) a method using an empirical Bayes estimate of the unbiasing factor, and (3) a robust nonparametric estimate of σ suggested by Quenouille. Because s tends to underestimate σ, its use as an estimate of a model parameter results in a tendency to underdesign. If underdesign losses are considered more serious than overdesign losses, then the choice of one of the less biased methods may be wise.
Özyemişci-Cebeci, Nuran; Yavuzyilmaz, Hüsnü
2013-06-01
Methods to improve the retention of telescopic crowns, including the application of friction varnish and electroforming, are available. However, information about their efficiency is limited. The purpose of this study was to compare the influence of 2 different friction varnishes and an electroforming method on the retention of telescopic crowns. Thirty inner and outer crowns were fabricated from cobalt-chromium-molybdenum alloy having lengths and cervical diameters of 6 mm, 2-degree tapers, and shoulder margins of 1 mm. Fifty-μm thick layers were removed from the internal surfaces of the outer crowns with a vertical machining center to simulate wear. The retentive forces of these specimens were measured with a testing machine. FGP friction varnish (FGP Friction-Fit-System), SD friction varnish (Servo-dental), and an electroforming method (GES\\Gold Electroforming System) were applied to the specimens. After the application of the 3 methods, retention values were measured, and the results analyzed with 1-way ANOVA, paired sample t test (α=.05). The increase in the retentive forces of all specimens was statistically significant (P<.01). The mean retentive forces increased from 3.6 N to 9.8 N for group FGP, 3.6 N to 4.6 N for group SD, and 3.7 N to 6.0 N for group EF. Group FGP was significantly different from group SD and group EF (P<.05), and no significant difference was observed between group SD and group EF. Mean standard deviation values of retentive forces for group FGP before, FGP after, SD before, SD after, EF before and EF after is 0.5, 2.7, 0.6, 1.3, 0.8, 2.3, respectively. Group FGP showed the maximum retention values. Group EF showed higher retention values than group SD. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vikraman, S; Karrthick, K; Rajesh, T
2014-06-15
Purpose: The purpose of this study was to evaluate quantitatively 2D versus 3D dosimetry for stereotactic volumetric modulated arc delivery using COMPASS with 2D array. Methods: Twenty-five patients CT images and RT structures of different sites like brain, head and neck, thorax, abdomen and spine were taken from Multiplan planning system for this study. All these patients underwent radical stereotactic treatment in Cyberknife. For each patient, linac based VMAT stereotactic plans were generated in Monaco TPS v 3.1 using Elekta Beam Modulator MLC. Dose prescription was in the range of 5-20Gy/fraction.TPS calculated VMAT plan delivery accuracy was quantitatively evaluated withmore » COMPASS measured dose and calculated dose based on DVH metrics. In order to ascertain the potential of COMPASS 3D dosimetry for stereotactic plan delivery, 2D fluence verification was performed with MatriXX using Multicube. Results: For each site, D{sub 9} {sub 5} was achieved with 100% of prescription dose with maximum 0.05SD. Conformity index (CI) was observed closer to 1.15 in all cases. Maximum deviation of 2.62 % was observed for D{sub 9} {sub 5} when compared TPS versus COMPASS measured. Considerable deviations were observed in head and neck cases compare to other sites. The maximum mean and standard deviation for D{sub 9} {sub 5}, average target dose and average gamma were -0.78±1.72, -1.10±1.373 and 0.39±0.086 respectively. Numbers of pixels passing 2D fluence verification were observed as a mean of 99.36% ±0.455 SD with 3% dose difference and 3mm DTA. For critical organs in head and neck cases, significant dose differences were observed in 3D dosimetry while the target doses were matched well within limit in both 2D and 3D dosimetry. Conclusion: The quantitative evaluations of 2D versus 3D dosimetry for stereotactic volumetric modulated plans showed the potential of highlighting the delivery errors. This study reveals that COMPASS 3D dosimetry is an effective tool for patient specific quality assurance compared to 2D fluence verification.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fried, D; Meier, J; Mawlawi, O
Purpose: Use a NEMA-IEC PET phantom to assess the robustness of FDG-PET-based radiomics features to changes in reconstruction parameters across different scanners. Methods: We scanned a NEMA-IEC PET phantom on 3 different scanners (GE Discovery VCT, GE Discovery 710, and Siemens mCT) using a FDG source-to-background ratio of 10:1. Images were retrospectively reconstructed using different iterations (2–3), subsets (21–24), Gaussian filter widths (2, 4, 6mm), and matrix sizes (128,192,256). The 710 and mCT used time-of-flight and point-spread-functions in reconstruction. The axial-image through the center of the 6 active spheres was used for analysis. A region-of-interest containing all spheres was ablemore » to simulate a heterogeneous lesion due to partial volume effects. Maximum voxel deviations from all retrospectively reconstructed images (18 per scanner) was compared to our standard clinical protocol. PET Images from 195 non-small cell lung cancer patients were used to compare feature variation. The ratio of a feature’s standard deviation from the patient cohort versus the phantom images was calculated to assess for feature robustness. Results: Across all images, the percentage of voxels differing by <1SUV and <2SUV ranged from 61–92% and 88–99%, respectively. Voxel-voxel similarity decreased when using higher resolution image matrices (192/256 versus 128) and was comparable across scanners. Taking the ratio of patient and phantom feature standard deviation was able to identify features that were not robust to changes in reconstruction parameters (e.g. co-occurrence correlation). Metrics found to be reasonably robust (standard deviation ratios > 3) were observed for routinely used SUV metrics (e.g. SUVmean and SUVmax) as well as some radiomics features (e.g. co-occurrence contrast, co-occurrence energy, standard deviation, and uniformity). Similar standard deviation ratios were observed across scanners. Conclusions: Our method enabled a comparison of feature variability across scanners and was able to identify features that were not robust to changes in reconstruction parameters.« less
NASA Astrophysics Data System (ADS)
Jung, Jae Hong; Jung, Joo-Young; Bae, Sun Hyun; Moon, Seong Kwon; Cho, Kwang Hwan
2016-10-01
The purpose of this study was to compare patient setup deviations for different image-guided protocols (weekly vs. biweekly) that are used in TomoDirect three-dimensional conformal radiotherapy (TD-3DCRT) for whole-breast radiation therapy (WBRT). A total of 138 defined megavoltage computed tomography (MVCT) image sets from 46 breast cancer cases were divided into two groups based on the imaging acquisition times: weekly or biweekly. The mean error, three-dimensional setup displacement error (3D-error), systematic error (Σ), and random error (σ) were calculated for each group. The 3D-errors were 4.29 ± 1.11 mm and 5.02 ± 1.85 mm for the weekly and biweekly groups, respectively; the biweekly error was 14.6% higher than the weekly error. The systematic errors in the roll angle and the x, y, and z directions were 0.48°, 1.72 mm, 2.18 mm, and 1.85 mm for the weekly protocol and 0.21°, 1.24 mm, 1.39 mm, and 1.85 mm for the biweekly protocol. Random errors in the roll angle and the x, y, and z directions were 25.7%, 40.6%, 40.0%, and 40.8% higher in the biweekly group than in the weekly group. For the x, y, and z directions, the distributions of the treatment frequency at less than 5 mm were 98.6%, 91.3%, and 94.2% in the weekly group and 94.2%, 89.9%, and 82.6% in the biweekly group. Moreover, the roll angles with 0 - 1° were 79.7% and 89.9% in the weekly and the biweekly groups, respectively. Overall, the evaluation of setup deviations for the two protocols revealed no significant differences (p > 0.05). Reducing the frequency of MVCT imaging could have promising effects on imaging doses and machine times during treatment. However, the biweekly protocol was associated with increased random setup deviations in the treatment. We have demonstrated a biweekly protocol of TD-3DCRT for WBRT, and we anticipate that our method may provide an alternative approach for considering the uncertainties in the patient setup.
Hatzichristodoulou, Georgios; Meisner, Christoph; Gschwend, Jürgen E; Stenzl, Arnulf; Lahme, Sven
2013-11-01
Extracorporeal shock wave therapy (ESWT) for treatment of Peyronie's disease (PD) is controversial. To study the efficacy of ESWT by a placebo-controlled, randomized trial. Patients with PD (n=102) were randomly assigned (n=51) to each group (ESWT or placebo). All patients were given 6 weekly treatments. Patients in the ESWT-group received 2,000 shock waves per session, using the Piezoson 100 lithotripter (Richard Wolf, Knittlingen, Germany). Patients in the placebo-group were treated with interposition of a plastic membrane, which prevented any transmission of shock waves. Primary end point was decrease of pain between baseline and after 4 weeks follow-up. Secondary end points were changes in deviation, plaque size, and sexual function. Pain was assessed by a visual analog scale. Deviation was measured by a goniometer after artificial erection using Alprostadil (Viridal®, Schwarz Pharma, Monheim, Germany). Plaque size was measured with a ruler and sexual function assessed by a scale regarding the ability to perform sexual intercourse. Overall, only 45 patients experienced pain at baseline. In the subgroup analysis of these patients, pain decreased in 17/20 (85.0%) patients in the ESWT group and 12/25 (48.0%) patients in the placebo group (P=0.013, relative risk [RR]=0.29, 95% confidence interval: 0.09-0.87). Penile deviation was not reduced by ESWT (P=0.66) but worsened in 20/50 (40%) and 12/49 (24.5%) patients of the ESWT and placebo-group, respectively (P=0.133). Plaque size reduction was not different between the two groups (P=0.33). Additional, plaque size increased in five patients (10.9%) of the ESWT group only. An improvement in sexual function could not be verified (P=0.126, RR=0.46). Despite some potential benefit of ESWT in regard to pain reduction, it should be emphasized that pain usually resolves spontaneously with time. Given this and the fact that deviation may worsen with ESWT, this treatment cannot be recommended. © 2013 International Society for Sexual Medicine.
Goozée, Justine V; Murdoch, Bruce E; Theodoros, Deborah G
2002-01-01
A miniature pressure transducer was used to assess the interlabial contact pressures produced by a group of 19 adults (mean age 30.6 years) with dysarthria following severe traumatic brain injury (TBI) during a set of speech and nonspeech tasks. Ten parameters relating to lip strength, endurance, rate of movement and lip pressure accuracy and stability were measured from the nonspeech tasks. The results attained by the TBI group were compared against a group of 19 age- and sex-matched control subjects. Significant differences between the groups were found for maximum interlabial contact pressure, maximum rate of repetition of maximum pressure, and lip pressure accuracy at 50 and 10% levels of maximum pressure. In regards to speech, the interlabial contact pressures generated by the TBI group and control group did not differ significantly. When expressed as percentages of maximum pressure, however, the TBI group's interlabial pressures appeared to have been generated with greater physiological effort. Copyright 2002 S. Karger AG, Basel
Melquiades, Fábio L; Thomaz, Edivaldo L
2016-05-01
An important aspect for the evaluation of fire effects in slash-and-burn agricultural system, as well as in wildfire, is the soil burn severity. The objective of this study is to estimate the maximum temperature reached in real soil burn events using energy dispersive X-ray fluorescence (EDXRF) as an analytical tool, combined with partial least square (PLS) regression. Muffle-heated soil samples were used for PLS regression model calibration and two real slash-and-burn soils were tested as external samples in the model. It was possible to associate EDXRF spectra alterations to the maximum temperature reached in the heat affected soils with about 17% relative standard deviation. The results are promising since the analysis is fast, nondestructive, and conducted after the burn event, although local calibration for each type of burned soil is necessary. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
NASA Astrophysics Data System (ADS)
Casas-Castillo, M. Carmen; Rodríguez-Solà, Raúl; Navarro, Xavier; Russo, Beniamino; Lastra, Antonio; González, Paula; Redaño, Angel
2018-01-01
The fractal behavior of extreme rainfall intensities registered between 1940 and 2012 by the Retiro Observatory of Madrid (Spain) has been examined, and a simple scaling regime ranging from 25 min to 3 days of duration has been identified. Thus, an intensity-duration-frequency (IDF) master equation of the location has been constructed in terms of the simple scaling formulation. The scaling behavior of probable maximum precipitation (PMP) for durations between 5 min and 24 h has also been verified. For the statistical estimation of the PMP, an envelope curve of the frequency factor ( k m ) based on a total of 10,194 station-years of annual maximum rainfall from 258 stations in Spain has been developed. This curve could be useful to estimate suitable values of PMP at any point of the Iberian Peninsula from basic statistical parameters (mean and standard deviation) of its rainfall series. [Figure not available: see fulltext.
DECONV-TOOL: An IDL based deconvolution software package
NASA Technical Reports Server (NTRS)
Varosi, F.; Landsman, W. B.
1992-01-01
There are a variety of algorithms for deconvolution of blurred images, each having its own criteria or statistic to be optimized in order to estimate the original image data. Using the Interactive Data Language (IDL), we have implemented the Maximum Likelihood, Maximum Entropy, Maximum Residual Likelihood, and sigma-CLEAN algorithms in a unified environment called DeConv_Tool. Most of the algorithms have as their goal the optimization of statistics such as standard deviation and mean of residuals. Shannon entropy, log-likelihood, and chi-square of the residual auto-correlation are computed by DeConv_Tool for the purpose of determining the performance and convergence of any particular method and comparisons between methods. DeConv_Tool allows interactive monitoring of the statistics and the deconvolved image during computation. The final results, and optionally, the intermediate results, are stored in a structure convenient for comparison between methods and review of the deconvolution computation. The routines comprising DeConv_Tool are available via anonymous FTP through the IDL Astronomy User's Library.
NASA Technical Reports Server (NTRS)
Wilson, Robert M.
1990-01-01
The level of skill in predicting the size of the sunspot cycle is investigated for the two types of precursor techniques, single variate and bivariate fits, both applied to cycle 22. The present level of growth in solar activity is compared to the mean level of growth (cycles 10-21) and to the predictions based on the precursor techniques. It is shown that, for cycle 22, both single variate methods (based on geomagnetic data) and bivariate methods suggest a maximum amplitude smaller than that observed for cycle 19, and possibly for cycle 21. Compared to the mean cycle, cycle 22 is presently behaving as if it were a +2.6 sigma cycle (maximum amplitude of about 225), which means that either it will be the first cycle not to be reliably predicted by the combined precursor techniques or its deviation relative to the mean cycle will substantially decrease over the next 18 months.
The impact of prism adaptation test on surgical outcomes in patients with primary exotropia.
Kiyak Yilmaz, Ayse; Kose, Suheyla; Guven Yilmaz, Suzan; Uretmen, Onder
2015-05-01
We aimed to determine the impact of the preoperative prism adaptation test (PAT) on surgical outcomes in patients with primary exotropia. Thirty-eight consecutive patients with primary exotropia were enrolled. Pre-operative PAT was performed in 18 randomly selected patients (Group 1). Surgery was based on the angle of deviation at distance measured after PAT. The remaining 20 patients in whom PAT was not performed comprised Group 2. Surgery was based on the angle of deviation at distance in these patients. Surgical success was defined as ocular alignment within eight prism dioptres (PD) of orthophoria. Satisfactory motor alignment (± 8 PD) was achieved in 16 Group 1 patients (88.9 per cent) and 16 Group 2 patients (80 per cent) one year after surgery (p = 0.6; chi-square test). There were no statistically significant differences in demographic parameters, pre-operative and post-operative angle of deviation between the two groups (p > 0.05; Mann-Whitney U and chi-square tests). Nine patients in Group 1 (50 per cent) and two patients in Group 2 (10 per cent) had increased binocular vision one year post-operatively. A statistically significant difference was determined in terms of change in binocular single vision between the two groups (p = 0.01; chi-square test). Although the prism adaptation test did not lead to a significant increment in motor success, it may be helpful in achieving a more favourable functional surgical outcome in patients with primary exotropia. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.
Inferior Oblique Overaction: Anterior Transposition Versus Myectomy.
Rajavi, Zhale; Feizi, Mohadeseh; Behradfar, Narges; Yaseri, Mehdi; Sayanjali, Shima; Motevaseli, Tahmine; Sabbaghi, Hamideh; Faghihi, Mohammad
2017-07-01
To compare the efficacy of inferior oblique myectomy and anterior transposition for correcting inferior oblique overaction (IOOA). This retrospective study was conducted on 56 patients with IOOA who had either myectomy or anterior transposition of the inferior oblique muscle from 2010 to 2015. The authors compared preoperative and postoperative inferior oblique muscle function grading (-4 to +4) as the main outcome measure and vertical and horizontal deviation, dissociated vertical deviation (DVD), and A- and V-pattern between the two surgical groups as secondary outcomes. A total of 99 eyes of 56 patients with a mean age of 5.9 ± 6.5 years were included (47 eyes in the myectomy group and 52 eyes in the anterior transposition group). There were no differences in preoperative best corrected visual acuity, amblyopia, spherical equivalent, and primary versus secondary IOOA between the two groups. Both surgical procedures were effective in reducing IOOA and satisfactory results were similar between the two groups: 61.7% and 67.3% in the myectomy and anterior transposition groups, respectively (P = .56). After adjustment for the preoperative DVD, there was no statistically significant difference between the two groups postoperatively. The preoperative hypertropia was 6 to 14 and 6 to 18 prism diopters (PD) in the myectomy and anterior transposition groups, respectively. After surgery, no patient had a vertical deviation greater than 5 PD. Both the inferior oblique myectomy and anterior transposition procedures are effective in reducing IOOA with similar satisfactory results. DVD and hypertropia were also corrected similarly by these two surgical procedures. [J Pediatr Ophthalmol Strabismus. 2017;54(4):232-237.]. Copyright 2017, SLACK Incorporated.
Fouad, Heba M; Abdelhakim, Mohamad A; Awadein, Ahmed; Elhilali, Hala
2016-10-01
To compare the outcomes of medial rectus (MR) muscle pulley fixation and augmented recession in children with convergence excess esotropia and variable-angle infantile esotropia. This was a prospective randomized interventional study in which children with convergence excess esotropia or variable-angle infantile esotropia were randomly allocated to either augmented MR muscle recession (augmented group) or MR muscle pulley posterior fixation (pulley group). In convergence excess, the MR recession was based on the average of distance and near angles of deviation with distance correction in the augmented group, and on the distance angle of deviation in the pulley group. In variable-angle infantile esotropia, the MR recession was based on the average of the largest and smallest angles in the augmented group and on the smallest angle in the pulley group. Pre- and postoperative ductions, versions, pattern strabismus, smallest and largest angles of deviation, and angle disparity were analyzed. Surgery was performed on 60 patients: 30 underwent bilateral augmented MR recession, and 30 underwent bilateral MR recession with pulley fixation. The success rate was statistically significantly higher (P = 0.037) in the pulley group (70%) than in the augmented group (40%). The postoperative smallest and largest angles and the angle disparity were statistically significantly lower in the pulley group than the augmented group (P < 0.01). Medial rectus muscle pulley fixation is a useful surgical step for addressing marked variability of the angle in variable angle esotropia and convergence excess esotropia. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Yang, Fei; Hou, Xianru; Wu, Huijuan; Bao, Yongzhen
2014-02-01
To evaluate the characteristics of postoperative refractive status in age-related cataract patients with shallow anterior chamber and the correlation between pre-operative anterior chamber depth and postoperative refractive status. Prospective case-control study. Sixty-eight cases (90 eyes) with age-related cataract were recruited from October 2010 to January 2012 in People's Hospital Peking University including 28 cases (34 eyes) in control group and 40 cases (56 eyes) in shallow anterior chamber group according to anterior chamber depth (ACD) measured by Pentacam system. Axial length and keratometer were measured by IOL Master and intraocular lens power was calculated using SRK/T formula. Postoperative refraction, ACD and comprehensive eye examination were performed at 1 month and 3 months after cataract surgery. Using SPSS13.0 software to establish a database, the two groups were compared with independent samples t-test and correlation analysis were performed with binary logical regression. The postoperative refractive deviation at 1 month were (-0.39 ± 0.62) D in control group and (+0.73 ± 0.26) D in shallow anterior chamber group respectively which present statistical significance between the two groups (P = 0.00, t = 3.67); the postoperative refractive deviation in 3 month was (-0.37 ± 0.62) D in control group and (+0.79 ± 0.28) D in shallow anterior chamber group operatively which present statistical significance between the two groups (P = 0.00, t = 3.33). In shallow anterior chamber group, with the shallower of ACD, the greater of refractive deviation (P = 0.00, r1 month = -0.57, r3 months = -0.61). Hyperopic shift existed in age-related cataract patients with shallow anterior chamber and the shallower of ACD was, the greater of hyperopic shift happened.
Mason, Heidi; DeRubeis, Mary Beth; Foster, Jared C.; Taylor, Jeremy M.G.; Worden, Francis P.
2016-01-01
Purpose/Objectives To determine whether improved monitoring through close follow-up with a nurse practitioner (NP) could enhance treatment compliance and decrease frequency of hospitalizations. Design Retrospective chart review. Setting An academic National Cancer Institute–designated comprehensive cancer center. Sample 151 patients aged 45–65 years diagnosed with stage III or IV oropharyngeal cancer. Methods Patients were nonrandomized to one of two groups: a prechemotherapy clinic group and a weekly NP-led clinic group. After examination of descriptive statistics, multiple linear and logistic regressions were used to compare groups across patient outcomes. Main Research Variables Hospitalization, chemotherapy dose deviations, and chemotherapy treatment completion. Findings The average number of visits during traditional treatment was three and, after initiation of the NP-led clinic, the number was six. The hospitalization rate was 28% in the traditional clinic group compared to 12% in the NP-led group. The rate of chemotherapy dose deviations was 48% in the traditional clinic group compared to 6% in the NP-led clinic group. Forty-six percent of patients in the traditional clinic group received the full seven scheduled doses of chemotherapy compared to 90% of patients seen in the NP-led clinic group. Conclusions A weekly NP-led symptom management clinic reduces rates of hospitalization and chemotherapy dose deviations and increases chemotherapy completion in patients receiving intensive chemoradiotherapy for oropharyngeal cancer. Implications for Nursing Patients receiving chemoradiotherapy benefit from close monitoring for toxicities by NPs to successfully complete their treatment and avoid hospitalization. Knowledge Translation Early interventions to manage toxicities in patients with head and neck cancer can improve outcomes. NPs are in a key position to manage these toxicities and, when symptoms are controlled, costs are reduced. PMID:24007925
Volumetric velocity measurements in restricted geometries using spiral sampling: a phantom study.
Nilsson, Anders; Revstedt, Johan; Heiberg, Einar; Ståhlberg, Freddy; Bloch, Karin Markenroth
2015-04-01
The aim of this study was to evaluate the accuracy of maximum velocity measurements using volumetric phase-contrast imaging with spiral readouts in a stenotic flow phantom. In a phantom model, maximum velocity, flow, pressure gradient, and streamline visualizations were evaluated using volumetric phase-contrast magnetic resonance imaging (MRI) with velocity encoding in one (extending on current clinical practice) and three directions (for characterization of the flow field) using spiral readouts. Results of maximum velocity and pressure drop were compared to computational fluid dynamics (CFD) simulations, as well as corresponding low-echo-time (TE) Cartesian data. Flow was compared to 2D through-plane phase contrast (PC) upstream from the restriction. Results obtained with 3D through-plane PC as well as 4D PC at shortest TE using a spiral readout showed excellent agreements with the maximum velocity values obtained with CFD (<1 % for both methods), while larger deviations were seen using Cartesian readouts (-2.3 and 13 %, respectively). Peak pressure drop calculations from 3D through-plane PC and 4D PC spiral sequences were respectively 14 and 13 % overestimated compared to CFD. Identification of the maximum velocity location, as well as the accurate velocity quantification can be obtained in stenotic regions using short-TE spiral volumetric PC imaging.
Vertical force and wrist deviation angle in a sample of elderly people using walkers.
Leung, Cherng-Yee; Yeh, Po-Chan
2013-02-01
Walkers are frequently used by elderly people with weak lower limbs and limited balance, but the ergonomic relationship between the use of a walker and stress on the upper limbs is relatively unstudied. The current study assessed wrist deviation and vertical force among elderly individuals using a walker for assistance in walking. 60 elderly volunteers (M age = 81.0 yr., SD = 8.8) participated, 30 of whom frequently used a walker, and 30 who had no such prior experience. Data were obtained from four load cells and a twin-axis wrist goniometer during assisted ambulation using the walker. No significant group difference was found in gait cycle. Significant wrist deviation occurred, with ulnar deviation/dorsiflexion of the right hand, which was greater than that of the left. Non-experienced participants had larger dorsiflexion than experienced participants. Experienced participants produced larger vertical force than non-experienced participants. The greaterthe wrist deviation, the greater was the vertical force. The horizontal handles of most marketed walkers cause wrist deviations. This is a concern for users, clinicians, and related industries. Improvements in walker design should be considered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, S.-W., E-mail: sunsw0819@163.com; Zhang, X., E-mail: zhangx@hit.edu.cn; Wang, G.-F.
A series of 2-arylidenebenzocycloalkanones containing heterocyclic rings 1–8 were prepared and characterized by IR, {sup 1}H NMR and elemental analyses. X-ray diffraction study of 6 reveals that the cyclohexyl ring of the 3,4-dihydronaphthalen-1(2H)-one adopts a chair conformation with a maximum deviation of 0.547(3) Å and makes dihedral angles of 52.24(17)° and 11.23(16)°, respectively, with the benzene plane and the mean plane of the benzimidazole ring.
4-Methoxy-N-(1-methyl-1H-indazol-5-yl)benzenesulfonamide
Chicha, Hakima; Rakib, El Mostapha; Geffken, Detlef; Saadi, Mohamed; El Ammari, Lahcen
2013-01-01
The indazole ring system [maximum deviation = 0.013 (2) Å] of the title compound, C15H15N3O3S, makes a dihedral angle of 50.11 (7)° with the benzene ring. In the crystal, cohesion is provided by C—H⋯O and N—H⋯N hydrogen bonds, which link the molecules into chains propagating along the b-axis direction. PMID:24427037
NASA Technical Reports Server (NTRS)
Schiess, J. R.
1994-01-01
Scientific data often contains random errors that make plotting and curve-fitting difficult. The Rational-Spline Approximation with Automatic Tension Adjustment algorithm lead to a flexible, smooth representation of experimental data. The user sets the conditions for each consecutive pair of knots:(knots are user-defined divisions in the data set) to apply no tension; to apply fixed tension; or to determine tension with a tension adjustment algorithm. The user also selects the number of knots, the knot abscissas, and the allowed maximum deviations from line segments. The selection of these quantities depends on the actual data and on the requirements of a particular application. This program differs from the usual spline under tension in that it allows the user to specify different tension values between each adjacent pair of knots rather than a constant tension over the entire data range. The subroutines use an automatic adjustment scheme that varies the tension parameter for each interval until the maximum deviation of the spline from the line joining the knots is less than or equal to a user-specified amount. This procedure frees the user from the drudgery of adjusting individual tension parameters while still giving control over the local behavior of the spline The Rational Spline program was written completely in FORTRAN for implementation on a CYBER 850 operating under NOS. It has a central memory requirement of approximately 1500 words. The program was released in 1988.
The MSFC Solar Activity Future Estimation (MSAFE) Model
NASA Technical Reports Server (NTRS)
Suggs, Ron
2017-01-01
The MSAFE model provides forecasts for the solar indices SSN, F10.7, and Ap. These solar indices are used as inputs to space environment models used in orbital spacecraft operations and space mission analysis. Forecasts from the MSAFE model are provided on the MSFC Natural Environments Branch's solar web page and are updated as new monthly observations become available. The MSAFE prediction routine employs a statistical technique that calculates deviations of past solar cycles from the mean cycle and performs a regression analysis to calculate the deviation from the mean cycle of the solar index at the next future time interval. The forecasts are initiated for a given cycle after about 8 to 9 monthly observations from the start of the cycle are collected. A forecast made at the beginning of cycle 24 using the MSAFE program captured the cycle fairly well with some difficulty in discerning the double peak that occurred at solar cycle maximum.
Simple programmable voltage reference for low frequency noise measurements
NASA Astrophysics Data System (ADS)
Ivanov, V. E.; Chye, En Un
2018-05-01
The paper presents a circuit design of a low-noise voltage reference based on an electric double-layer capacitor, a microcontroller and a general purpose DAC. A large capacitance value (1F and more) makes it possible to create low-pass filter with a large time constant, effectively reducing low-frequency noise beyond its bandwidth. Choosing the optimum value of the resistor in the RC filter, one can achieve the best ratio between the transient time, the deviation of the output voltage from the set point and the minimum noise cut-off frequency. As experiments have shown, the spectral density of the voltage at a frequency of 1 kHz does not exceed 1.2 nV/√Hz the maximum deviation of the output voltage from the predetermined does not exceed 1.4 % and depends on the holding time of the previous value. Subsequently, this error is reduced to a constant value and can be compensated.
Numerical Investigations of Slip Phenomena in Centrifugal Compressor Impellers
NASA Astrophysics Data System (ADS)
Huang, Jeng-Min; Luo, Kai-Wei; Chen, Ching-Fu; Chiang, Chung-Ping; Wu, Teng-Yuan; Chen, Chun-Han
2013-03-01
This study systematically investigates the slip phenomena in the centrifugal air compressor impellers by CFD. Eight impeller blades for different specific speeds, wrap angles and exit blade angles are designed by compressor design software to analyze their flow fields. Except for the above three variables, flow rate and number of blades are the other two. Results show that the deviation angle decreases as the flow rate increases. The specific speed is not an important parameter regarding deviation angle or slip factor for general centrifugal compressor impellers. The slip onset position is closely related to the position of the peak value in the blade loading factor distribution. When no recirculation flow is present at the shroud, the variations of slip factor under various flow rates are mainly determined by difference between maximum blade angle and exit blade angle, Δβmax-2. The solidity should be of little importance to slip factor correlations in centrifugal compressor impellers.
Laskaris, G.; Yan, X.; Mueller, J. M.; ...
2015-10-01
We report new measurements of the double-polarized photodisintegration of 3He at an incident photon energy of 16.5 MeV, carried out at the High Intensity γ-ray Source (HIγS) facility located at Triangle Universities Nuclear Laboratory (TUNL). The spin-dependent double-differential cross sections and the contribution from the three-body channel to the Gerasimov–Drell–Hearn (GDH) integrand were extracted and compared with the state-of-the-art three-body calculations. The calculations, which include the Coulomb interaction and are in good agreement with the results of previous measurements at 12.8 and 14.7 MeV, deviate from the new cross section results at 16.5 MeV. Lastly, the GDH integrand was foundmore » to be about one standard deviation larger than the maximum value predicted by the theories.« less
Modulation of cosmic-ray protons and helium nuclei near solar maximum
NASA Technical Reports Server (NTRS)
Rygg, T. A.; Ogallagher, J. J.; Earl, J. A.
1974-01-01
Balloon observations of proton and helium spectra in 1970, 1971 and 1972, reveal a factor of approximately 1.85 deviation from a single valued regression at low rigidities. This deviation decreases with increasing rigidity for both species. The period 1969-1970 is unique because time variations at low and high energies were anti-correlated. When satellite observations are used to extend the balloon observations to energies below 100 MeV/Nucleon, the proton spectrum showed a steeper slope in 1970 and 1972 than the characteristic J = AT spectrum observed during 1965-1969. The slope of the helium spectrum became continuously flatter during the same period (1970-1972). Computer generated spectra based on simple two parameter modulation models describe the basic features of the observations if one of the variable parameters is used to characterize the rigidity dependence of the diffusion coefficient. Models which do not allow such a variation are not consistent with the observations.
NASA Technical Reports Server (NTRS)
Wang, J. C.
1982-01-01
Compositional segregation of solid solution semiconducting alloys in the radial direction during unidirectional solidification was investigated by calculating the effect of a curved solid liquid interface on solute concentration at the interface on the solid. The formulation is similar to that given by Coriell, Boisvert, Rehm, and Sekerka except that a more realistic cylindrical coordinate system which is moving with the interface is used. Analytical results were obtained for very small and very large values of beta with beta = VR/D, where V is the velocity of solidification, R the radius of the specimen, and D the diffusivity of solute in the liquid. For both very small and very large beta, the solute concentration at the interface in the solid C(si) approaches C(o) (original solute concentration) i.e., the deviation is minimal. The maximum deviation of C(si) from C(o) occurs for some intermediate value of beta.
S-193 scatterometer backscattering cross section precision/accuracy for Skylab 2 and 3 missions
NASA Technical Reports Server (NTRS)
Krishen, K.; Pounds, D. J.
1975-01-01
Procedures for measuring the precision and accuracy with which the S-193 scatterometer measured the background cross section of ground scenes are described. Homogeneous ground sites were selected, and data from Skylab missions were analyzed. The precision was expressed as the standard deviation of the scatterometer-acquired backscattering cross section. In special cases, inference of the precision of measurement was made by considering the total range from the maximum to minimum of the backscatter measurements within a data segment, rather than the standard deviation. For Skylab 2 and 3 missions a precision better than 1.5 dB is indicated. This procedure indicates an accuracy of better than 3 dB for the Skylab 2 and 3 missions. The estimates of precision and accuracy given in this report are for backscattering cross sections from -28 to 18 dB. Outside this range the precision and accuracy decrease significantly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qian, Yun; Long, Charles N.; Wang, Hailong
2012-02-17
Cloud Fraction (CF) is the dominant modulator of radiative fluxes. In this study, we evaluate CF simulations in the IPCC AR4 GCMs against ARM ground measurements, with a focus on the vertical structure, total amount of cloud and its effect on cloud shortwave transmissivity, for both inter-model deviation and model-measurement discrepancy. Our intercomparisons of three CF or sky-cover related dataset reveal that the relative differences are usually less than 10% (5%) for multi-year monthly (annual) mean values, while daily differences are quite significant. The results also show that the model-observation and the inter-model deviations have a similar magnitude for themore » total CF (TCF) and the normalized cloud effect, and they are twice as large as the surface downward solar radiation and cloud transmissivity. This implies that the other cloud properties, such as cloud optical depth and height, have a similar magnitude of disparity to TCF among the GCMs, and suggests that a better agreement among the GCMs in solar radiative fluxes could be the result of compensating errors in either cloud vertical structure, cloud optical depth or cloud fraction. Similar deviation pattern between inter-model and model-measurement suggests that the climate models tend to generate larger bias against observations for those variables with larger inter-model deviation. The simulated TCF from IPCC AR4 GCMs are very scattered through all seasons over three ARM sites: Southern Great Plains (SGP), Manus, Papua New Guinea and North Slope of Alaska (NSA). The GCMs perform better at SGP than at Manus and NSA in simulating the seasonal variation and probability distribution of TCF; however, the TCF in these models is remarkably underpredicted and cloud transmissivity is less susceptible to the change of TCF than the observed at SGP. Much larger inter-model deviation and model bias are found over NSA than the other sites in estimating the TCF, cloud transmissivity and cloud-radiation interaction, suggesting that the Arctic region continues to challenge cloud simulations in climate models. Most of the GCMs tend to underpredict CF and fail to capture the seasonal variation of CF at middle and low levels in the tropics. The high altitude CF is much larger in the GCMs than the observation and the inter-model variability of CF also reaches maximum at high levels in the tropics. Most of the GCMs tend to underpredict CF by 50-150% relative to the measurement average at low and middle levels over SGP. While the GCMs generally capture the maximum CF in the boundary layer and vertical variability, the inter-model deviation is largest near surface over the Arctic. The internal variability of CF simulated in ensemble runs with the same model is very minimal.« less
Characteristics of a novel treatment system for linear accelerator–based stereotactic radiosurgery
Li, Haisen; Song, Kwang; Chin‐Snyder, Karen; Qin, Yujiao; Kim, Jinkoo; Bellon, Maria; Gulam, Misbah; Gardner, Stephen; Doemer, Anthony; Devpura, Suneetha; Gordon, James; Chetty, Indrin; Siddiqui, Farzan; Ajlouni, Munther; Pompa, Robert; Hammoud, Zane; Simoff, Michael; Kalkanis, Steven; Movsas, Benjamin; Siddiqui, M. Salim
2015-01-01
The purpose of this study is to characterize the dosimetric properties and accuracy of a novel treatment platform (Edge radiosurgery system) for localizing and treating patients with frameless, image‐guided stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). Initial measurements of various components of the system, such as a comprehensive assessment of the dosimetric properties of the flattening filter‐free (FFF) beams for both high definition (HD120) MLC and conical cone‐based treatment, positioning accuracy and beam attenuation of a six degree of freedom (6DoF) couch, treatment head leakage test, and integrated end‐to‐end accuracy tests, have been performed. The end‐to‐end test of the system was performed by CT imaging a phantom and registering hidden targets on the treatment couch to determine the localization accuracy of the optical surface monitoring system (OSMS), cone‐beam CT (CBCT), and MV imaging systems, as well as the radiation isocenter targeting accuracy. The deviations between the percent depth‐dose curves acquired on the new linac‐based system (Edge), and the previously published machine with FFF beams (TrueBeam) beyond Dmax were within 1.0% for both energies. The maximum deviation of output factors between the Edge and TrueBeam was 1.6%. The optimized dosimetric leaf gap values, which were fitted using Eclipse dose calculations and measurements based on representative spine radiosurgery plans, were 0.700 mm and 1.000 mm, respectively. For the conical cones, 6X FFF has sharper penumbra ranging from 1.2−1.8 mm (80%‐20%) and 1.9−3.8 mm (90%‐10%) relative to 10X FFF, which has 1.2−2.2 mm and 2.3−5.1 mm, respectively. The relative attenuation measurements of the couch for PA, PA (rails‐in), oblique, oblique (rails‐out), oblique (rails‐in) were: −2.0%, −2.5%, −15.6%, −2.5%, −5.0% for 6X FFF and −1.4%, −1.5%, −12.2%, −2.5%, −5.0% for 10X FFF, respectively, with a slight decrease in attenuation versus field size. The systematic deviation between the OSMS and CBCT was −0.4±0.2 mm, 0.1±0.3 mm, and 0.0±0.1 mm in the vertical, longitudinal, and lateral directions. The mean values and standard deviations of the average deviation and maximum deviation of the daily Winston‐Lutz tests over three months are 0.20±0.03 mm and 0.66±0.18 mm, respectively. Initial testing of this novel system demonstrates the technology to be highly accurate and suitable for frameless, linac‐based SRS and SBRT treatment. PACS number: 87.56.J‐ PMID:26218998
Gode, Sercan; Benzer, Murat; Uslu, Mustafa; Kaya, Isa; Midilli, Rasit; Karci, Bulent
2018-02-01
Severe dorsal deviations in crooked noses are treated by either in situ septoplasty with asymmetric spreader grafts (ISS) or extracorporeal subtotal septal reconstruction (ECS). To our knowledge, except one retrospective study, there is no other that compares the objective and subjective results of these two treatment modalities. The aim of this study was to compare the aesthetic and functional outcomes of ECS and ISS in crooked noses. This study was carried out on 40 patients (ISS in 20 patients and ECS in 20 patients) who underwent external rhinoplasty surgery due to crooked noses between May 2014 and January 2016. While performing rhinoplasty on the patients, the decision of whether to use the ECS or ISS technique was randomized in a sequential fashion. Surgical outcomes were assessed and compared using the anthropometric measurement of photographs with Rhinobase software. Subjective assessments of nasal obstruction and aesthetic satisfaction were evaluated with a visual analog scale. There was a significant difference between rhinion deviation angle, supratip deviation angle (SDA) and tip deviation angle pre- and postoperatively in the ECS group, whereas in the ISS group, except SDA, all other postoperative angles were significantly improved from preoperative values (p = 0.218). The nasal tip projection in the ECS and ISS groups was 29.48, 31.5 preoperatively and 29.78, 31.26 postoperatively. The mean postoperative nasal tip projection value (p > 0.005) did not change significantly compared to the preoperative value in both groups. The mean postoperative value of nasolabial (p = 0.226) angle did not change significantly compared to the mean preoperative one in the ECS group. However, in the ISS group, the mean postoperative value of nasolabial (p = 0.001) angle significantly improved compared to the mean preoperative value. There was significant improvement in both groups, while improvements in both functional and aesthetic outcomes were much higher in the extracorporeal group. None of the patients had postoperative nasal obstruction that required revision surgery. One patient underwent revision rhinoplasty due to an irregularity on the nasal dorsum in the ECS group. This is the first study that compares subjective and objective aesthetic and functional outcomes of crooked nose surgery according to two common septoplasty techniques in a randomized self-controlled fashion. This study was effective in both objectively and subjectively comparing the functional and aesthetic aspect of the patients submitted to two common different techniques of treatment of nasal deviations in crooked nose patients. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Quantifying anti-gravity torques for the design of a powered exoskeleton.
Ragonesi, Daniel; Agrawal, Sunil K; Sample, Whitney; Rahman, Tariq
2013-03-01
Designing an upper extremity exoskeleton for people with arm weakness requires knowledge of the joint torques due to gravity and joint stiffness, as well as, active residual force capabilities of users. The objective of this research paper is to describe the characteristics of the upper limb of children with upper limb impairment. This paper describes the experimental measurements of the torque on the upper limb due to gravity and joint stiffness of three groups of subjects: able-bodied adults, able-bodied children, and children with neuromuscular disabilities. The experiment involves moving the arm to various positions in the sagittal plane and measuring the resultant force at the forearm. This force is then converted to torques at the elbow and shoulder. These data are compared to a two-link lumped mass model based on anthropomorphic data. Results show that the torques based on anthropometry deviate from experimentally measured torques as the arm goes through the range. Subjects with disabilities also maximally pushed and pulled against the force sensor to measure maximum strength as a function of arm orientation. For all subjects, the maximum voluntary applied torque at the shoulder and elbow in the sagittal plane was found to be lower than gravity torques throughout the disabled subjects' range of motion. This experiment informs designers of upper limb orthoses on the contribution of passive human joint torques due to gravity and joint stiffness and the strength capability of targeted users.
Christ, Andreas; Gosselin, Marie-Christine; Kühn, Sven; Kuster, Niels
2010-07-01
The electromagnetic exposure of cell phone users depends on several parameters. One of the most dominant of these is the distance between the cell phone and the head tissue. The pinna can be regarded as a spacer between the top of the phone and the head tissue. The size of this spacer has not yet been systematically studied. The objective of this article is to investigate the variations of distance as a function of age of the exposed person, and the mechanical force on the pinna and how it affects the peak spatial specific absorption rate (psSAR). The distances were measured for adults and children (6-8 years of age) while applying a well-defined force on the pinna using a custom-developed measurement device. The average distances of the pinnae to the heads and their standard deviations showed no major differences between the two age groups: 10.5 +/- 2.0 mm for children (6-8 years) and 9.5 +/- 2.0 mm for adults. The pinnae of our anatomical high-resolution head models of one adult and two children were transformed according to the measurement results. The numerical exposure analysis showed that the reduced distance due to the pinna compression can increase the maximum 10 g psSAR by approximately 2 dB for adults and children, if the exposure maximum is associated with the upper part of the phone. 2010 Wiley-Liss, Inc.
A cloud physics investigation utilizing Skylab data
NASA Technical Reports Server (NTRS)
Alishouse, J.; Jacobowitz, H.; Wark, D. (Principal Investigator)
1975-01-01
The author has identified the following significant results. The Lowtran 2 program, S191 spectral response, and solar spectrum were used to compute the expected absorption by 2.0 micron band for a variety of cloud pressure levels and solar zenith angles. Analysis of the three long wavelength data channels continued in which it was found necessary to impose a minimum radiance criterion. It was also found necessary to modify the computer program to permit the computation of mean values and standard deviations for selected subsets of data on a given tape. A technique for computing the integrated absorption in the A band was devised. The technique normalizes the relative maximum at approximately .78 micron to the solar irradiance curve and then adjusts the relative maximum at approximately .74 micron to fit the solar curve.
NASA Astrophysics Data System (ADS)
Gagné, Olivier; Hawthorne, Frank; Shannon, Robert D.; Fischer, Reinhard X.
2017-09-01
Empirical electronic polarizabilities allow the prediction of total mineral polarizabilities and mean refractive indices of the vast majority of minerals and synthetic oxides. However, deviations from the valence-sum rule at cations in some minerals are associated with large deviations of observed from calculated total polarizabilities. We have identified several groups of minerals and compounds where deviations from the valence-sum rule at cations lead to polarizability deviations of 2-5%: M(SO4)·nH2O, n = 1-6, blödite-group minerals [Na2M2+(SO4)2·4H2O], and the kieserite-related minerals: isokite, panasqueiraite and tilasite. In these minerals, the environment of the M ions contains both O and H2O: Mg[O4(H2O)2] in kieserite, szmikite, and szomolnokite; Mg[O2(H2O)4] in starkeyite, ilesite, and rozenite, and Mg[(H2O)6] in hexahydrite. In compounds where the ligands are only H2O, deviations from the valence-sum rule at the M(H2O)6 groups are not accompanied by significant polarizability deviations. This is the case for epsomite, MgSO4·7H2O; bieberite, CoSO4·7H2O; goslarite, ZnSO4·7H2O, six silicofluorides, MSiF6·6H2O; eighteen Tutton's salts, M2M'(SO4)2·6H2O, where M = K, Rb, Cs and M' = Mg, Mn, Fe, Co, Ni, Cu, and Zn; and eleven MM'(SO4)2·12H2O alums, where M = Na, K, Rb and Cs, and M' = Al, Cr, Ga and In. This is also the case for the sulfates alunogen, Al2(SO4)3·17H2O and halotrichite, FeAl2(SO4)4·22H2O; three hydrated nitrates; one phosphate; three antimonates and two hydrated perchlorates. A possible explanation for this different behavior is that the bond-valence model treats O and H separately, whereas polarizability calculations treat the polarizability of the entire H2O molecule.
Temperature effects on wavelength calibration of the optical spectrum analyzer
NASA Astrophysics Data System (ADS)
Mongkonsatit, Kittiphong; Ranusawud, Monludee; Srikham, Sitthichai; Bhatranand, Apichai; Jiraraksopakun, Yuttapong
2018-03-01
This paper presents the investigation of the temperature effects on wavelength calibration of an optical spectrum analyzer or OSA. The characteristics of wavelength dependence on temperatures are described and demonstrated under the guidance of the IEC 62129-1:2006, the international standard for the Calibration of wavelength/optical frequency measurement instruments - Part 1: Optical spectrum analyzer. Three distributed-feedback lasers emit lights with wavelengths of 1310 nm, 1550 nm, and 1600 nm were used as light sources in this work. Each light was split by a 1 x 2 fiber splitter whereas one end was connected to a standard wavelength meter and the other to an under-test OSA. Two Experiment setups were arranged for the analysis of the wavelength reading deviations between a standard wavelength meter and an OSA under a variety of circumstances of different temperatures and humidity conditions. The experimental results showed that, for wavelengths of 1550 nm and 1600 nm, the wavelength deviations were proportional to the value of temperature with the minimum and maximum of -0.015 and 0.030 nm, respectively. While the deviations of 1310 nm wavelength did not change much with the temperature as they were in the range of -0.003 nm to 0.010 nm. The measurement uncertainty was also evaluated according to the IEC 62129-1:2006. The main contribution of measurement uncertainty was caused by the wavelength deviation. The uncertainty of measurement in this study is 0.023 nm with coverage factor, k = 2.
Efficiency of thin magnetically arrested discs around black holes
NASA Astrophysics Data System (ADS)
Avara, Mark J.; McKinney, Jonathan C.; Reynolds, Christopher S.
2016-10-01
The radiative and jet efficiencies of thin magnetized accretion discs around black holes (BHs) are affected by BH spin and the presence of a magnetic field that, when strong, could lead to large deviations from Novikov-Thorne (NT) thin disc theory. To seek the maximum deviations, we perform general relativistic magnetohydrodynamic simulations of radiatively efficient thin (half-height H to radius R of H/R ≈ 0.10) discs around moderately rotating BHs with a/M = 0.5. First, our simulations, each evolved for more than 70 000 rg/c (gravitational radius rg and speed of light c), show that large-scale magnetic field readily accretes inward even through our thin disc and builds-up to the magnetically arrested disc (MAD) state. Secondly, our simulations of thin MADs show the disc achieves a radiative efficiency of ηr ≈ 15 per cent (after estimating photon capture), which is about twice the NT value of ηr ˜ 8 per cent for a/M = 0.5 and gives the same luminosity as an NT disc with a/M ≈ 0.9. Compared to prior simulations with ≲10 per cent deviations, our result of an ≈80 per cent deviation sets a new benchmark. Building on prior work, we are now able to complete an important scaling law which suggests that observed jet quenching in the high-soft state in BH X-ray binaries is consistent with an ever-present MAD state with a weak yet sustained jet.
Analysis of graphic representation ability in oscillation phenomena
NASA Astrophysics Data System (ADS)
Dewi, A. R. C.; Putra, N. M. D.; Susilo
2018-03-01
This study aims to investigates how the ability of students to representation graphs of linear function and harmonic function in understanding of oscillation phenomena. Method of this research used mix methods with concurrent embedded design. The subjects were 35 students of class X MIA 3 SMA 1 Bae Kudus. Data collection through giving essays and interviews that lead to the ability to read and draw graphs in material of Hooke's law and oscillation characteristics. The results of study showed that most of the students had difficulty in drawing graph of linear function and harmonic function of deviation with time. Students’ difficulties in drawing the graph of linear function is the difficulty of analyzing the variable data needed in graph making, confusing the placement of variable data on the coordinate axis, the difficulty of determining the scale interval on each coordinate, and the variation of how to connect the dots forming the graph. Students’ difficulties in representing the graph of harmonic function is to determine the time interval of sine harmonic function, the difficulty to determine the initial deviation point of the drawing, the difficulty of finding the deviation equation of the case of oscillation characteristics and the confusion to different among the maximum deviation (amplitude) with the length of the spring caused the load.Complexity of the characteristic attributes of the oscillation phenomena graphs, students tend to show less well the ability of graphical representation of harmonic functions than the performance of the graphical representation of linear functions.
Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms
2018-01-01
To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p <0.05) and modulation transfer function (MTF) ( p <0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p <0.05). Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.
Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit MS
2018-01-01
Purpose To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was −0.89±0.35 D in group I and −0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. PMID:29731603
Randomized clinical trial comparing control of maxillary anchorage with 2 retraction techniques.
Xu, Tian-Min; Zhang, Xiaoyun; Oh, Hee Soo; Boyd, Robert L; Korn, Edward L; Baumrind, Sheldon
2010-11-01
The objective of this pilot randomized clinical trial was to investigate the relative effectiveness of anchorage conservation of en-masse and 2-step retraction techniques during maximum anchorage treatment in patients with Angle Class I and Class II malocclusions. Sixty-four growing subjects (25 boys, 39 girls; 10.2-15.9 years old) who required maximum anchorage were randomized to 2 treatment techniques: en-masse retraction (n = 32) and 2-step retraction (n = 32); the groups were stratified by sex and starting age. Each patient was treated by a full-time clinic instructor experienced in the use of both retraction techniques at the orthodontic clinic of Peking University School of Stomatology in China. All patients used headgear, and most had transpalatal appliances. Lateral cephalograms taken before treatment and at the end of treatment were used to evaluate treatment-associated changes. Differences in maxillary molar mesial displacement and maxillary incisor retraction were measured with the before and after treatment tracings superimposed on the anatomic best fit of the palatal structures. Differences in mesial displacement of the maxillary first molar were compared between the 2 treatment techniques, between sexes, and between different starting-age groups. Average mesial displacement of the maxillary first molar was slightly less in the en-masse group than in the 2-step group (mean, -0.36 mm; 95% CI, -1.42 to 0.71 mm). The average mesial displacement of the maxillary first molar for both treatment groups pooled (n = 63, because 1 patient was lost to follow-up) was 4.3 ± 2.1 mm (mean ± standard deviation). Boys had significantly more mesial displacement than girls (mean difference, 1.3 mm; P <0.03). Younger adolescents had significantly more mesial displacement than older adolescents (mean difference, 1.3 mm; P <0.02). Average mesial displacement of the maxillary first molar with 2-step retraction was slightly greater than that for en-masse retraction, but the difference did not reach statistical significance. This finding appears to contradict the belief of many clinicians that 2-step canine retraction is more effective than en-masse retraction in preventing clinically meaningful anchorage loss. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Pokhrel, Damodar; Badkul, Rajeev; Jiang, Hongyu; Kumar, Pravesh; Wang, Fen
2015-01-08
For stereotactic ablative body radiotherapy (SABR) in lung cancer patients, Radiation Therapy Oncology Group (RTOG) protocols currently require radiation dose to be calculated using tissue heterogeneity corrections. Dosimetric criteria of RTOG 0813 were established based on the results obtained from non-Monte Carlo (MC) algorithms, such as superposition/convolutions. Clinically, MC-based algorithms are now routinely used for lung SABR dose calculations. It is essential to confirm that MC calculations in lung SABR meet RTOG guidelines. This report evaluates iPlan MC plans for SABR in lung cancer patients using dose-volume histogram normalization per current RTOG 0813 compliance criteria. Eighteen Stage I-II non-small cell lung cancer (NSCLC) patients with centrally located tumors, who underwent MC-based lung SABR with heterogeneity correction using X-ray Voxel Monte Carlo (XVMC) algorithm (BrainLAB iPlan version 4.1.2), were analyzed. Total dose of 60 Gy in 5 fractions was delivered to planning target volume (PTV) with at least V100% = 95%. Internal target volumes (ITVs) were delineated on maximum intensity projection (MIP) images of 4D CT scans. PTV (ITV + 5 mm margin) volumes ranged from 10.0 to 99.9 cc (mean = 36.8 ± 20.7 cc). Organs at risk (OARs) were delineated on average images of 4D CT scans. Optimal clinical MC SABR plans were generated using a combination of non-coplanar conformal arcs and beams for the Novalis-TX consisting of high definition multileaf collimators (MLCs) and 6 MV-SRS (1000 MU/min) mode. All plans were evaluated using the RTOG 0813 high and intermediate dose spillage criteria: conformity index (R100%), ratio of 50% isodose volume to the PTV (R50%), maximum dose 2 cm away from PTV in any direction (D2 cm), and percent of normal lung receiving 20 Gy (V20) or more. Other organs-at-risk (OARs) doses were tabulated, including the volume of normal lung receiving 5 Gy (V5), maximum cord dose, dose to < 15 cc of heart, and dose to <5 cc of esophagus. Only six out of 18 patients met all RTOG 0813 compliance criteria. Eight of 18 patients had minor deviations in R100%, four in R50%, and nine in D2 cm. However, only one patient had minor deviation in V20. All other OARs doses, such as maximum cord dose, dose to < 15 cc of heart, and dose to < 5 cc of esophagus, were satisfactory for RTOG criteria, except for one patient, for whom the dose to < 15 cc of heart was higher than RTOG guidelines. The preliminary results for our limited iPlan XVMC dose calculations indicate that the majority (i.e., 2/3) of our patients had minor deviations in the dosimetric guidelines set by RTOG 0813 protocol in one way or another. When using an exclusive highly sophisticated XVMC algorithm, the RTOG 0813 dosimetric compliance criteria such as R100% and D2 cm may need to be revisited. Based on our limited number of patient datasets, in general, about 6% for R100% and 9% for D2 cm corrections could be applied to pass the RTOG 0813 compliance criteria in most of those patients. More patient plans need to be evaluated to make recommendation for R50%. No adjustment is necessary for OAR dose tolerances, including normal lung V20. In order to establish new MC specific dose parameters, further investigation with a large cohort of patients including central, as well as peripheral lung tumors, is anticipated and strongly recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leheta, D; Shvydka, D; Parsai, E
2015-06-15
Purpose: For the photon dose calculation Philips Pinnacle Treatment Planning System (TPS) uses collapsed cone convolution algorithm, which relies on energy spectrum of the beam in computing the scatter component. The spectrum is modeled based on Linac’s standard commissioning data and typically is not independently verified. We explored a methodology of using transmission measurements in combination with regularization data processing to unfold Linac spectra. The measured spectra were compared to those modeled by the TPS, and the effect on patient plans was evaluated. Methods: Transmission measurements were conducted in narrow-beam geometry using a standard Farmer ionization chamber. Two attenuating materialsmore » and two build -up caps, having different atomic numbers, served to enhance discrimination between absorption of low and high-energy portions of the spectra, thus improving the accuracy of the results. The data was analyzed using a regularization technique implemented through spreadsheet-based calculations. Results: The unfolded spectra were found to deviate from the TPS beam models. The effect of such deviations on treatment planning was evaluated for patient plans through dose distribution calculations with either TPS modeled or measured energy spectra. The differences were reviewed through comparison of isodose distributions, and quantified based on maximum dose values for critical structures. While in most cases no drastic differences in the calculated doses were observed, plans with deviations of 4 to 8% in the maximum dose values for critical structures were discovered. The anatomical sites with large scatter contributions are the most vulnerable to inaccuracies in the modeled spectrum. Conclusion: An independent check of the TPS model spectrum is highly desirable and should be included as part of commissioning of a new Linac. The effect is particularly important for dose calculations in high heterogeneity regions. The developed approach makes acquisition of megavoltage Linac beam spectra achievable in a typical radiation oncology clinic.« less
Pielmeier, Ricarda; Kerkmann, Andrea; Distl, Ottmar
2012-01-01
Shortness of the lower jaw (brachygnathia inferior, underbite) is a common anomaly in sheep. In order to study the age-dependent development of brachygnathia inferior, data of 73 East Friesian milk sheep from a breeding experiment over six generations were analysed. Data were recorded in regular intervals of four weeks from birth up to an age of at least 25 weeks. Brachygnathia inferior was determined by the distance between the edge of the central incisor of the lower jaw and the anterior surrounding of the upper jaw (DIFF-UK) using a measuring tape. Four main types of brachygnathia inferior were distinguished using means, standard deviations and maximum values of the individual animals.The thresholds were a maximum and mean DIFF-UK of 0.5 cm and a standard deviation of 0.266 cm. A total of 14 sheep (main types 3 and 4) showed an obvious brachygnathia inferior with mean DIFF-UK larger than 0.5 cm whereof ten animals showed a large variation of DIFF-UK values (standard deviation > 0.226 cm). Mean DIFF-UK values of 59 sheep were smaller than 0.5 cm (main types 1 and 2). One of these 59 animals had during the first four weeks of life DIFF-UK values of 1 cm and than decreasing values reaching zero within the next nine months (main type 2). Five of the 58 animals with main type 1 had a perfect occlusion of jaws, all with DIFF-UK values at zero during the whole recording period. Parents with severe or mild brachygnathia inferior had severely affected progeny. Selection of sheep for breeding with a perfect occlusion of jaws decreases the risk to pass on the hereditary disposition for brachygnathia inferior. An early inspection of potential breeding animals is advisable to detect all cases of brachygnathia inferior even if the underbite decreases in the first year of life.
Anderson, J L; Pratt, C M; Waldo, A L; Karagounis, L A
1997-01-01
In his book Deadly Medicine and on television, Thomas Moore impugns the process of antiarrhythmic drug approval in the 1980s, alleging that the new generation of drugs had flooded the marketplace and had caused deaths in numbers comparable to lives lost during war. To assess these important public health allegations, we evaluated annual coronary artery disease death rates in relation to antiarrhythmic drug sales (2 independent marketing surveys). Predicted mortality rates were modeled using linear regression analysis for 1982 through 1991. Deviations from predicted linearity were sought in relation to rising and falling class IC and overall class I antiarrhythmic drug use. Flecainide came to market in 1986 and encainide in 1987. Combined class IC sales peaked in 1987 and 1988 (maximum market penetration, 20%, first quarter 1989). Results of the Cardiac Arrhythmia Suppression Trial (CAST) were disclosed in April 1989. Overall annual class I antiarrhythmic prescription sales actually fell slightly (-3% to -4%/yr) in the 2 years before CAST and then more abruptly (- 12%) in the year after CAST (1990). Sales of class IC drugs fell dramatically after CAST (by 75%). Coronary death rates (age adjusted) fell in a linear fashion during the decade of 1982 through 1991. No deviation from predicted rates was observed during the introduction, rise, and fall in class IC (and other class I) sales: rates were 126/100,000 in 1985 (before flecainide), 114 and 110 in 1987 and 1988 (maximum sales), and 103 in 1990 (after CAST). Deviations in death rates in the postulated range of 6,000 to 25,000 per year were shown to be excluded easily by the 95% confidence intervals about the predicted rates. Entry of new antiarrhythmic drugs in the 1980s did not lead to overall market expansion and had no adverse impact on coronary artery disease death rates, which fell progressively. Thus, the allegations in Deadly Medicine could not be confirmed.
Maradzike, Elvis; Gidofalvi, Gergely; Turney, Justin M; Schaefer, Henry F; DePrince, A Eugene
2017-09-12
Analytic energy gradients are presented for a variational two-electron reduced-density-matrix (2-RDM)-driven complete active space self-consistent field (CASSCF) method. The active-space 2-RDM is determined using a semidefinite programing (SDP) algorithm built upon an augmented Lagrangian formalism. Expressions for analytic gradients are simplified by the fact that the Lagrangian is stationary with respect to variations in both the primal and the dual solutions to the SDP problem. Orbital response contributions to the gradient are identical to those that arise in conventional CASSCF methods in which the electronic structure of the active space is described by a full configuration interaction (CI) wave function. We explore the relative performance of variational 2-RDM (v2RDM)- and CI-driven CASSCF for the equilibrium geometries of 20 small molecules. When enforcing two-particle N-representability conditions, full-valence v2RDM-CASSCF-optimized bond lengths display a mean unsigned error of 0.0060 Å and a maximum unsigned error of 0.0265 Å, relative to those obtained from full-valence CI-CASSCF. When enforcing partial three-particle N-representability conditions, the mean and maximum unsigned errors are reduced to only 0.0006 and 0.0054 Å, respectively. For these same molecules, full-valence v2RDM-CASSCF bond lengths computed in the cc-pVQZ basis set deviate from experimentally determined ones on average by 0.017 and 0.011 Å when enforcing two- and three-particle conditions, respectively, whereas CI-CASSCF displays an average deviation of 0.010 Å. The v2RDM-CASSCF approach with two-particle conditions is also applied to the equilibrium geometry of pentacene; optimized bond lengths deviate from those derived from experiment, on average, by 0.015 Å when using a cc-pVDZ basis set and a (22e,22o) active space.
Vieira, Edgar R; Brunt, Denis
2016-02-01
To evaluate if wearing unstable shoes reduces low back pain and disability in nurses. A randomized controlled trial. Hospitals and homecare. A total of 20 matched female registered nurses with low back pain. The mean (standard deviation) age was 31 years (5) for the control and 34 years (6) for the intervention group; height was 161 cm (5) and 165 cm (7), respectively. The intervention group received unstable shoes at Week 2 to wear for at least 36 h/week for a month. The Oswestry Low Back Pain Disability Questionnaire and a visual analogue pain scale. The mean (standard deviation) pain level was 6 (1) at baseline vs. 6 (2) at Week 6 for the control group, and 5 (1) vs. 1 (1) for the intervention group. The mean (standard deviation) disability level was 31% (9) at baseline vs. 28% (7) at Week 6 for the control, and 27% (12) vs. 13% (5) for the intervention group. There were no significant changes over time on pain or disability levels for the control group. The intervention group reported lower levels of pain on Weeks 4 (mean difference ⩾-1.4, p ⩽ 0.009) and 6 (mean difference ⩾-3.1, p < 0.001). Disability levels were also lower on Weeks 4 (mean difference = -4.5%, p NS) and 6 (mean difference = -14.1%, p = 0.020). Wearing unstable shoes reduced low back pain and disability in nurses and might be helpful as part of the back pain rehabilitation process. © The Author(s) 2015.
Marghalani, Amin; Weber, Hans-Peter; Finkelman, Matthew; Kudara, Yukio; El Rafie, Khaled; Papaspyridakos, Panos
2018-04-01
To the authors' knowledge, while accuracy outcomes of the TRIOS scanner have been compared with conventional impressions, no available data are available regarding the accuracy of digital scans with the Omnicam and True Definition scanners versus conventional impressions for partially edentulous arches. The purpose of this in vitro study was to compare the accuracy of digital implant scans using 2 different intraoral scanners (IOSs) with that of conventional impressions for partially edentulous arches. Two partially edentulous mandibular casts with 2 implant analogs with a 30-degree angulation from 2 different implant systems (Replace Select RP; Nobel Biocare and Tissue level RN; Straumann) were used as controls. Sixty digital models were made from these 2 definitive casts in 6 different groups (n=10). Splinted implant-level impression procedures followed by digitization were used to produce the first 2 groups. The next 2 groups were produced by digital scanning with Omnicam. The last 2 groups were produced by digital scanning with the True Definition scanner. Accuracy was evaluated by superimposing the digital files of each test group onto the digital file of the controls with inspection software. The difference in 3-dimensional (3D) deviations (median ±interquartile range) among the 3 impression groups for Nobel Biocare was statistically significant among all groups (P<.001), except for the Omnicam (20 ±4 μm) and True Definition (15 ±6 μm) groups; the median ±interquartile range for the conventional group was 39 ±18 μm. The difference in 3D deviations among the 3 impression groups for Straumann was statistically significant among all groups (P=.003), except for the conventional impression (22 ±5 μm) and True Definition (17 ±5 μm) groups; the median ±interquartile range for the Omnicam group was 26 ±15 μm. The difference in 3D deviations between the 2 implant systems was significant for the Omnicam (P=.011) and conventional (P<.001) impression techniques but not for the True Definition technique (P=.247). Within the limitations of this study, both the impression technique and the implant system affected accuracy. The True Definition technique had the fewest 3D deviations compared with the other 2 techniques; however, the accuracy of all impression techniques was within clinically acceptable levels, and not all differences were statistically significant. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kassa, Tsegaye; Tilahun, Samson; Damtie, Baylie
2017-09-01
This paper was aimed at investigating the solar variations of vTEC as a function of solar activity parameters, EUV and F10.7 radio flux. The daily values of ionospheric vertical Total Electron Content (vTEC) were observed using a dual frequency GPS receiver deployed at Bahir Dar (11.6°N and 37.36°E), Ethiopia. Measurements were taken during the period of 2010-2014 for successive five years and analysis was done on only quiet day observations. A quadratic fit was used as a model to describe the daily variation of vTEC in relation to solar parameters. Linear and non-linear coefficients of the vTEC variations were calculated in order to capture the trend of the variation. The variation of vTEC have showed good agreement with the trend of solar parameters in almost all of the days we consider during the period of our observations. We have explicitly observed days with insignificant TECU deviation (eg. modeling with respect to EUV, DOY = 49 in 2010 and modeling with respect to F10.7, DOY = 125 in 2012 and the like) and days with maximum deviation (about 50 TECU). A maximum deviation were observed, on average, during months of equinox whereas minimum during solstice months. This implies that there is a need to consider more parameters, including EUV and F10.7, that can affect the variation of vTEC during equinox seasons. Relatively, small deviations was observed in modeling vTEC as a function of EUV compared to that of the variation due to F10.7 cm flux. This may also tell us that EUV can be more suitable in modeling the solar variation of vTEC especially for longterm trends. Even though, the linear trend of solar variations of vTEC was frequently observed, significant saturation and amplification trends of the solar variations of vTEC were also observed to some extent across the months of the years we have analyzed. This mixed trend of the solar variation of vTEC implies the need for thorough investigation on the effect of solar parameters on TEC. However, based on long-term dataset, we came to conclude that the solar variations of vTEC is dominated by its linear pattern.
Dukic, T; Hanson, L; Falkmer, T
2006-01-15
The study examined the effects of manual control locations on two groups of randomly selected young and old drivers in relation to visual time off road, steering wheel deviation and safety perception. Measures of visual time off road, steering wheel deviations and safety perception were performed with young and old drivers during real traffic. The results showed an effect of both driver's age and button location on the dependent variables. Older drivers spent longer visual time off road when pushing the buttons and had larger steering wheel deviations. Moreover, the greater the eccentricity between the normal line of sight and the button locations, the longer the visual time off road and the larger the steering wheel deviations. No interaction effect between button location and age was found with regard to visual time off road. Button location had an effect on perceived safety: the further away from the normal line of sight the lower the rating.
The phonatory deviation diagram: a novel objective measurement of vocal function.
Madazio, Glaucya; Leão, Sylvia; Behlau, Mara
2011-01-01
To identify the discriminative characteristics of the phonatory deviation diagram (PDD) in rough, breathy and tense voices. One hundred and ninety-six samples of normal and dysphonic voices from adults were submitted to perceptual auditory evaluation, focusing on the predominant vocal quality and the degree of deviation. Acoustic analysis was performed with the VoxMetria (CTS Informatica). Significant differences were observed between the dysphonic and normal groups (p < 0.001), and also between the breathy and rough samples (p = 0.044) and the breathy and tense samples (p < 0.001). All normal voices were positioned in the inferior left quadrant, 45% of the rough voices in the inferior right quadrant, 52.6% of the breathy voices in the superior right quadrant and 54.3% of the tense voices in the inferior left quadrant of the PDD. In the inferior left quadrant, 93.8% of voices with no deviation were located and 72.7% of voices with mild deviation; voices with moderate deviation were distributed in the inferior and superior right quadrants, the latter ones containing the most deviant voices and 80% of voices with severe deviation. The PDD was able to discriminate normal from dysphonic voices, and the distribution was related to the type and degree of voice alteration. Copyright © 2011 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, S; Jacob, R; Popple, R
Purpose Fiducial-based imaging is often used in IGRT. Traditional gold fiducial marker often has substantial reconstruction artifacts. These artifacts Result in poor image quality of DRR for online kV-to-DRR matching. This study evaluated the image quality of PEEK in DRR in static and moving phantom. Methods CT scan of the Gold and PEEK fiducial (both 1×3 mm) was acquired in a 22 cm cylindrical phantom filled with water. Image artifacts was evaluated with maximum CT value deviated from water due to artifacts; volume of artifacts in 10×10 cm in the center slice; maximum length of streak artifacts from the fiducial.more » DRR resolution were measured using FWHM and FWTM. 4DCT of PEEK fiducial was acquired with the phantom moving sinusoidally in superior-inferior direction. Motion artifacts were assessed for various 4D phase angles. Results The maximum CT value deviation was −174 for Gold and −24 for PEEK. The volume of artifacts in a 10x10 cm 3 mm slice was 0.369 for Gold and 0.074 cm3 for PEEK. The maximum length of streak artifact was 80mm for Gold and 7 mm for PEEK. PEEK in DRR, FWHM was close to actual (1.0 mm for Gold and 1.1 mm for PEEK). FWTM was 1.8 mm for Gold and 1.3 mm for PEEK in DRR. Barrel motion artifact of PEEK fiducial was noticeable for free-breathing scan. The apparent PEEK length due to residual motion was in close agreement with the calculated length (13 mm for 30–70 phase, 10 mm in 40–60 phase). Conclusion Streak artifacts on planning CT associated with use of gold fiducial can be significantly reduced by PEEK fiducial, while having adequate kV image contrast. DRR image resolution at FWTM was improved from 1.8 mm to 1.3 mm. Because of this improvement, we have been routinely use PEEK for liver IGRT.« less
1987 Annual Report of the Reservoir Control Center, Southwestern Division, Army Corps of Engineers
1988-01-01
sediment ranges along the MClellan-Kerr Arkansas River Navigation Project. Due to the funding priorities assigned to reservoir sedimentation resurveys, it’ s...winter with the majority being released in February and March 1988. Numerous small deviations, which ranged from channel work to bridge construction...1987. This was still within the range of the conservation pool. The maximum pool elevation was 6,222.54 (61,668 ac-ft) on 20 June. Pueblo Reservoir is a
Ground and Flight Testing for Aircraft Guidance and Control,
1984-12-01
almost rigid structure (Figure 3). It is equipped with control surfa- - S ces (inner flaps, outer flaps, elevator) which are driven by fast acting...extremely fast -response actuators com- bined with a full fly-by-wire/light system is envisaged. The technology for doing this is not yet available today...6.6 late S Standard deviation 23.7 (77.8) 6.5 12.0 *Maximum error 51.5 (169) high 12.9 fast 29.0 late *The values of these errors were judged by the
The Effects of Tank Crew Turbulence on Tank Gunnery Performance
1978-09-01
complete. Crewmen’s responses were converted to mouths for all itqms and tabulated for analysis. Because data was tabulated to two digits a maximum...two- digit data tabulation, mean and standard deviation statistics are somewhat conserva- tive for items 8, 9, and 10. There were 14-1S% of the TCs who...Benjamin Harrison. ATTN Libary I HQOA (DAMA-ARI I USAPACDC. Ft SBenjamuun Haritson, ATTN; ATCP-IHR I HOCIA OAPE HRE PO) IUSA Comrm- Elect Sch
Lumped Parameter experiments for Single Mode Fiber Laser Cutting of Thin Stainless Steel Plate
NASA Astrophysics Data System (ADS)
Lai, Shengying; Jia, Ye; Han, Bing; Wang, Jun; Liu, Zongkai; Ni, Xiaowu; Shen, Zhonghua; Lu, Jian
2017-06-01
The present work reports the parameters on laser cutting stainless steel including workpiece thickness, cutting speed, defocus length and assisting gas pressure. The cutting kerf width, dross attachment and cut edge squareness deviation are examined to provide information on cutting quality. The results show that with the increasing thickness, the cutting speed decrease rate is about 27%. The optimal ranges of cutting speed, defocus length and gas pressure are obtained with maximum quality. The first section in your paper
2015-03-26
sciences. According to the article, gender stereotyping was still an issue for women in STEM while treatment in other fields improved. The authors...Minimum Maximum Sum Mean Std. Deviation Gender DV (1= Male ) .00 1.00 50.00 .7692 .42460 Google Scholar Articles 0 192 2658 42.87 38.863 Years...Predictors: (Constant), Gender DV (1= Male ) Dependent Variable: Rank Results of analysis supported the hypothesis that gender is a predictor of the
Characteristics of a p-Si detector in high energy electron fields.
Rikner, G
1985-01-01
Comparison of depth ionization distributions from a silicon semiconductor detector and depth dose curves from a plane parallel ionization chamber show that a semiconductor detector of p-type is well suited for relative electron dosimetry in the energy range of 6 to 20 MeV in Ep,0. Maximum deviations of the order of 1.5 per cent and of 1 mm were obtained down to a phantom depth of about 1 mm. The directional dependence of the detector was about 4 per cent.
Propyl 3-oxo-2,3-dihydro-1,2-benzothiazole-2-carboxylate
Wang, Xiang-hui; Yang, Jian-xin; You, Cheng-hang; Lin, Qiang
2011-01-01
The title compound, C11H11NO3S, was synthesized by the reaction of benzo[d]isothiazol-3(2H)-one with propyl carbonochloridate in toluene. The benzoisothiazolone ring system is approximately planar with a maximum deviation from the mean plane of 0.0226 (14) Å for the N atom. Weak intermolecular C—H⋯O hydrogen bonding occurs in the crystal structure. PMID:22065833
Pope, Larry M.; Diaz, A.M.
1982-01-01
Quality-of-water data, collected October 21-23, 1980, and a statistical summary are presented for 42 coal-mined strip pits in Crawford and Cherokee Counties, Southeastern Kansas. The statistical summary includes minimum and maximum observed values , mean, and standard deviation. Simple linear regression equations relating specific conductance, dissolved solids, and acidity to concentrations of dissolved solids, sulfate, calcium, and magnesium, potassium, aluminum, and iron are also presented. (USGS)
Partition thermodynamics of ionic surfactants between phosphatidylcholine vesicle and water phases
NASA Astrophysics Data System (ADS)
Chu, Shin-Chi; Hung, Chia-Hui; Wang, Shun-Cheng; Tsao, Heng-Kwong
2003-08-01
The partition of ionic surfactants (sodium alkyl sulfate and alkyl trimethyl ammonium bromide) between phosphatidylcholine vesicles and aqueous phase is investigated by simple conductometry under different temperatures. The experimental results can be well represented by the proposed regular solution theory and the thermodynamic parameters satisfy the thermodynamic consistency. The deviation from ideal partition is manifested through the effective interaction energy between lipid and surfactant wb, which is O(kT) large. It is found that wb rises as the alkyl chain is decreased for a specified head group. This is attributed to significant mismatch of chain lengths between surfactant and lipid molecules. The partition coefficient K declines with increasing temperature. The energy barrier from bilayer to aqueous phase, Δμ/kT∝ln K, is in the range of 16-26 kJ/mol. As the alkyl chain length is decreased for a given head group, Δμ is lowered by 1.3-1.5 kJ/mol per methylene group. Two independent analyses are employed to confirm this result. Using the thermodynamic parameters determined from experiments, the internal energy, entropy, and free energy of the partition process can be derived. Partition is essentially driven by the internal energy gain. The solubilizing ability, which is represented by the maximum surfactant-lipid ratio in the bilayer, Reb also decreases in accord with the K parameter. It is because the change in temperature influences the surfactant incorporation into the bilayer more than the formation of micelles.
Georgiadou, Elisavet; Stenström, Kristina Eriksson; Uvo, Cintia Bertacchi; Nilsson, Peter; Skog, Göran; Mattsson, Sören
2013-05-01
The (14)C content of 60 human blood serum samples from residents of Malmö (Sweden) in 1978, obtained from a biobank, has been measured to estimate the accuracy of (14)C bomb-pulse dating. The difference between the date estimated using the Calibomb software and sampling date varied between -3 ± 0.4 and +0.2 ± 0.5 years. The average age deviation of all samples was -1.5 ± 0.7 years, with the delay between production and consumption of foodstuffs being probably the dominating cause. The potential influence of food habits on the (14)C date has been evaluated using stable isotope δ(13)C and δ(15)N analysis and information about the dietary habits of the investigated individuals. Although the group consisting of lacto-ovo vegetarians and vegans (pooled group) was not completely separated from the omnivores in a stable isotopic trophic level diagram, this analysis proved to add valuable information on probable dietary habits. The age deviation of the sampling date from the respective Calibomb date was found strongly correlated with the δ(13)C values, probably due to influence from marine diet components. For the omnivore individuals, there were indications of seasonal effects on δ(13)C and the age deviation. No significant correlation was found between the age deviation and the δ(15)N values of any dietary group. No influence of sex or year of birth was found on neither the (14)C nor the δ(13)C and δ(15)N values of the serum samples. The data were also divided into two groups (omnivores and pooled group), based on the level of δ(15)N in the samples. The consumption of high δ(15)N-valued fish and birds can be responsible for this clustering.
Laboratory studies of methane near 2 μ m
NASA Astrophysics Data System (ADS)
Robert, O.; Hilico, J. C.; Loete, M.; Brown, L. R.; Pine, A. S.
2000-12-01
The 2 μ m region is a ``window" region for planets and stars abundant in methane. Characterizing the methane absorptions requires that a large number of vibration-rotation states be studied. The rovibrational levels in methane are grouped in vibrational polyads. The absorption from the three first polyads of methane (ground state: <= 10 μ m, dyad: 5--10 μ m, pentad: 3--5 μ m) are well understood and can be predicted using quantum mechanical models. Two higher polyads must be modeled to describe the 2 μ m window. The polyad called the octad has eight vibrational states in the 2--3 μ m interval. The next polyad (tetradecad) observed in the range 1.6--2 μ m is composed of 14 vibrational levels. The analyses of these two polyads have been undertaken at Dijon using high--quality FTIR spectra recorded at Kitt Peak National Observatory. The analysis of the octad was helped by spectra of the Q-branch regions of the 3ν 4 and ν2+2ν4 bands recorded at 80 K at NIST. The theoretical background for modeling rovibrational energy levels and corresponding transitions has been developed at Dijon. The analysis of the COMPLETE octad was performed for J <= 16 with a Hamiltonian containing 253 adjustable parameters (for 8 bands and 24 subbands). Nearly 8000 lines in the octad were assigned and reproduced with a standard deviation of 0.044 cm-1. Intensities were also modeled to 16% for some 2500 transitions. A prediction of some 57000 methane transitions in HITRAN format is available (from Brown). The analysis of the tetradecad system led to the assignment of nearly 200 lines of 4ν 4 band around 1.9 μ m, yielding a standard deviation of 0.180 cm-1, and to nearly 300 lines of 2ν 2+ν_3 around 1.7 μ m, yielding a standard deviation of 0.270 cm-1. Intensities are being measured. The spectral simulation is in progress near 1.8 μ m where maximum complication occurs. Part of the research reported in this paper was performed at the Jet Propulsion Laboratory, California Institute of Technology, under contract with the National Aeronautics and Space Administration
Group III Acceptors with Shallow and Deep Levels in Silicon Carbide: ESR and ENDOR Studies
NASA Astrophysics Data System (ADS)
Il'in, I. V.; Uspenskaya, Yu. A.; Kramushchenko, D. D.; Muzafarova, M. V.; Soltamov, V. A.; Mokhov, E. N.; Baranov, P. G.
2018-04-01
Results of investigations of Group III acceptors (B, Al, and Ga) in crystals of silicon carbide using the most informative electron spin resonance and electron nuclear double resonance methods are presented. Structural models of the acceptors with shallow and deep levels are considered. In addition to the data obtained earlier, studies using high-frequency magnetic resonance were obtained, which allowed revealing orthorhombic deviations from the axial symmetry for the deep acceptors; theoretical analysis explains experimentally found shifts of g factors for the deep acceptors arising due to the orthorhombic deviations, which appear probably due to the Jahn-Teller effect.
NASA Astrophysics Data System (ADS)
Khellat, M. R.; Mirjalili, A.
2017-03-01
We first consider the idea of renormalization group-induced estimates, in the context of optimization procedures, for the Brodsky-Lepage-Mackenzie approach to generate higher-order contributions to QCD perturbative series. Secondly, we develop the deviation pattern approach (DPA) in which through a series of comparisons between lowerorder RG-induced estimates and the corresponding analytical calculations, one could modify higher-order RG-induced estimates. Finally, using the normal estimation procedure and DPA, we get estimates of αs4 corrections for the Bjorken sum rule of polarized deep-inelastic scattering and for the non-singlet contribution to the Adler function.
Framework for behavioral analytics in anomaly identification
NASA Astrophysics Data System (ADS)
Touma, Maroun; Bertino, Elisa; Rivera, Brian; Verma, Dinesh; Calo, Seraphin
2017-05-01
Behavioral Analytics (BA) relies on digital breadcrumbs to build user profiles and create clusters of entities that exhibit a large degree of similarity. The prevailing assumption is that an entity will assimilate the group behavior of the cluster it belongs to. Our understanding of BA and its application in different domains continues to evolve and is a direct result of the growing interest in Machine Learning research. When trying to detect security threats, we use BA techniques to identify anomalies, defined in this paper as deviation from the group behavior. Early research papers in this field reveal a high number of false positives where a security alert is triggered based on deviation from the cluster learned behavior but still within the norm of what the system defines as an acceptable behavior. Further, domain specific security policies tend to be narrow and inadequately represent what an entity can do. Hence, they: a) limit the amount of useful data during the learning phase; and, b) lead to violation of policy during the execution phase. In this paper, we propose a framework for future research on the role of policies and behavior security in a coalition setting with emphasis on anomaly detection and individual's deviation from group activities.
Kirkpatrick, Daniel L; Hasham, Hasnain; Collins, Zachary; Johnson, Philip; Lemons, Steven; Shahzada, Hassan; Hunt, Suzanne L; Walter, Carissa; Hill, Jacqueline; Fahrbach, Thomas
2018-05-01
To determine whether treating benign biliary strictures via a stricture protocol reduced the probability of developing symptomatic recurrence and requiring surgical revision compared to nonprotocol treatment. A stricture protocol was designed to include serial upsizing of internal/external biliary drainage catheters to a target maximum dilation of 18-French, optional cholangioplasty at each upsizing, and maintenance of the largest catheter for at least 6 months. Patients were included in this retrospective analysis if they underwent biliary ductal dilation at a single institution from 2005 to 2016. Forty-two patients were included, 25 women and 17 men, with an average age of 51.9 years (standard deviation ± 14.6). Logistic regression models were used to determine the probability of symptomatic recurrence and surgical revision by stricture treatment type. Twenty-two patients received nonprotocol treatment, while 20 received treatment on a stricture protocol. After treatment, 7 (32%) patients in the nonprotocol group experienced clinical or laboratory recurrence of a benign stricture, whereas only 1 patient in the stricture protocol group experienced symptom recurrence. Patients in the protocol group were 8.9 times (95% confidence interval [CI] = 1.4-175.3) more likely to remain symptom free than patients in the nonprotocol group. Moreover, patients in the protocol group had an estimated 89% reduction in the probability of undergoing surgical revision compared to patients receiving nonprotocol treatment (odds ratio = .11, 95% CI = .01-.73). Establishing a stricture protocol may decrease the risk of stricture recurrence and the need for surgical revision when compared to a nonprotocol treatment approach. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Tarai, Madhumita; Mishra, Ashok Kumar
2016-10-12
The phenomenon of concentration dependent red shift, often observed in synchronous fluorescence spectra (SFS) of monofluorophoric as well as multifluorophoric systems at high chromophore concentrations, is known to have good analytical advantages. This was previously understood in terms of large inner filter effect (IFE) through the introduction of a derived absorption spectral profile that closely corresponds to the SFS profile. Using representative monofluorophoric and multifluorophoric systems, it is now explained how the SF spectral maximum changes with concentration of the fluorophore. For dilute solutions of monofluorophores the maximum is unchanged as expected. It is shown here that the onset of red shift of SFS maximum of both the mono as well as the multifluorophoric systems must occur at the derived absorption spectral parameter value of 0.32 that corresponds to the absorbance value of 0.87. This value is unique irrespective of the nature of the fluorophore under study. For monofluorophoric systems, the wavelength of derived absorption spectral maximum and the wavelength of synchronous fluorescence spectral maximum closely correspond with each other in the entire concentration range. In contrast, for multifluorophoric systems like diesel and aqueous humic acid, large deviations were noted that could be explained as to be due to the presence of non-fluorescing chromophores in the system. This work bridges the entire fluorophore concentration range over which the red shift of SFS maximum sets in; and in the process it establishes the importance of the derived absorption spectral parameter in understanding the phenomenon of concentration dependent red shift of SFS maximum. Copyright © 2016 Elsevier B.V. All rights reserved.
Estimating missing daily temperature extremes in Jaffna, Sri Lanka
NASA Astrophysics Data System (ADS)
Thevakaran, A.; Sonnadara, D. U. J.
2018-04-01
The accuracy of reconstructing missing daily temperature extremes in the Jaffna climatological station, situated in the northern part of the dry zone of Sri Lanka, is presented. The adopted method utilizes standard departures of daily maximum and minimum temperature values at four neighbouring stations, Mannar, Anuradhapura, Puttalam and Trincomalee to estimate the standard departures of daily maximum and minimum temperatures at the target station, Jaffna. The daily maximum and minimum temperatures from 1966 to 1980 (15 years) were used to test the validity of the method. The accuracy of the estimation is higher for daily maximum temperature compared to daily minimum temperature. About 95% of the estimated daily maximum temperatures are within ±1.5 °C of the observed values. For daily minimum temperature, the percentage is about 92. By calculating the standard deviation of the difference in estimated and observed values, we have shown that the error in estimating the daily maximum and minimum temperatures is ±0.7 and ±0.9 °C, respectively. To obtain the best accuracy when estimating the missing daily temperature extremes, it is important to include Mannar which is the nearest station to the target station, Jaffna. We conclude from the analysis that the method can be applied successfully to reconstruct the missing daily temperature extremes in Jaffna where no data is available due to frequent disruptions caused by civil unrests and hostilities in the region during the period, 1984 to 2000.
Human sensorimotor tracking of continuous subliminal deviations from isochrony.
Madison, Guy; Merker, Björn
2004-11-03
We show that people continuously react to time perturbations in the range 3-96 ms in otherwise isochronous sound sequences. Musically trained and untrained participants were asked to synchronize with a sequence of sounds, and these two groups performed almost equally below the threshold for conscious detection of the perturbations. Above this threshold the motor reactions accounted for a larger proportion of the stimulus deviations in musically trained participants.
Sigrist, Roland; Rauter, Georg; Marchal-Crespo, Laura; Riener, Robert; Wolf, Peter
2015-03-01
Concurrent augmented feedback has been shown to be less effective for learning simple motor tasks than for complex tasks. However, as mostly artificial tasks have been investigated, transfer of results to tasks in sports and rehabilitation remains unknown. Therefore, in this study, the effect of different concurrent feedback was evaluated in trunk-arm rowing. It was then investigated whether multimodal audiovisual and visuohaptic feedback are more effective for learning than visual feedback only. Naïve subjects (N = 24) trained in three groups on a highly realistic virtual reality-based rowing simulator. In the visual feedback group, the subject's oar was superimposed to the target oar, which continuously became more transparent when the deviation between the oars decreased. Moreover, a trace of the subject's trajectory emerged if deviations exceeded a threshold. The audiovisual feedback group trained with oar movement sonification in addition to visual feedback to facilitate learning of the velocity profile. In the visuohaptic group, the oar movement was inhibited by path deviation-dependent braking forces to enhance learning of spatial aspects. All groups significantly decreased the spatial error (tendency in visual group) and velocity error from baseline to the retention tests. Audiovisual feedback fostered learning of the velocity profile significantly more than visuohaptic feedback. The study revealed that well-designed concurrent feedback fosters complex task learning, especially if the advantages of different modalities are exploited. Further studies should analyze the impact of within-feedback design parameters and the transferability of the results to other tasks in sports and rehabilitation.
HU deviation in lung and bone tissues: Characterization and a corrective strategy.
Ai, Hua A; Meier, Joseph G; Wendt, Richard E
2018-05-01
In the era of precision medicine, quantitative applications of x-ray Computed Tomography (CT) are on the rise. These require accurate measurement of the CT number, also known as the Hounsfield Unit. In this study, we evaluated the effect of patient attenuation-induced beam hardening of the x-ray spectrum on the accuracy of the HU values and a strategy to correct for the resulting deviations in the measured HU values. A CIRS electron density phantom was scanned on a Siemens Biograph mCT Flow CT scanner and a GE Discovery 710 CT scanner using standard techniques that are employed in the clinic to assess the HU deviation caused by beam hardening in different tissue types. In addition, an anthropomorphic ATOM adult male upper torso phantom was scanned on the GE Discovery 710 scanner. Various amounts of Superflab bolus material were wrapped around the phantoms to simulate different patient sizes. The mean HU values that were measured in the phantoms were evaluated as a function of the water-equivalent area (A w ), a parameter that is described in the report of AAPM Task Group 220. A strategy by which to correct the HU values was developed and tested. The variation in the HU values in the anthropomorphic ATOM phantom under different simulated body sizes, both before and after correction, were compared, with a focus on the lung and bone tissues. Significant HU deviations that depended on the simulated patient size were observed. A positive correlation between HU and A w was observed for tissue types that have an HU of less than zero, while a negative correlation was observed for tissue types with HU values that are greater than zero. The magnitude of the difference increases as the underlying attenuation property deviates further away from that of water. In the electron density phantom study, the maximum observed HU differences between the measured and reference values in the cortical bone and lung materials were 426 and 94 HU, respectively. In the anthropomorphic phantom study, the HU difference was as much as -136.7 ± 8.2 HU (or -7.6% ± 0.5% of the attenuation coefficient, AC) in the spine region, and up to 37.6 ± 1.6 HU (or 17.3% ± 0.8% of AC) in the lung region between scenarios that simulated normal and obese patients. Our HU correction method reduced the HU deviations to 8.5 ± 9.1 HU (or 0.5% ± 0.5%) for bone and to -6.4 ± 1.7 HU (or -3.0% ± 0.8%) for lung. The HU differences in the soft tissue materials before and after the correction were insignificant. Visual improvement of the tissue contrast was also achieved in the data of the simulated obese patient. The effect of a patient's size on the HU values of lung and bone tissues can be significant. The accuracy of those HU values was substantially improved by the correction method that was developed for and employed in this study. © 2018 American Association of Physicists in Medicine.
Ecological quality boundary-setting procedures: the Gulf of Riga case study.
Aigars, Juris; Müller-Karulis, Bärbel; Martin, Georg; Jermakovs, Vadims
2008-03-01
Two approaches for setting ecological class boundaries, response curves and a simplified mathematical boundary-setting protocol, were tested for coastal, transitional and open waters in the Gulf of Riga, Baltic Sea. The simplified mathematical boundary-setting protocol defines acceptable ecological status based on expert judgment by a uniform relative deviation from reference conditions. In contrast, response curves derive class boundary definitions from observed changes in biological quality elements along environmental pressure gradients for class boundary definitions. Identification of relevant environmental pressures for the construction of response curves was based on a conceptual model of eutrophication in the Gulf of Riga. Response curves were successfully established for summer chlorophyll a and transparency, as well as for macrozoobenthos abundance in the Central Gulf, macrozoobenthos biotic coefficient in the Southern Gulf, and maximum depth of phytobenthos in the Northern Gulf. In the Gulf of Riga response curves almost always permitted a larger deviation from reference conditions than the 50% deviation applied for the simplified mathematical boundary-setting protocol. The case study clearly demonstrated that class boundary definitions should take into account the sensitivity of the target water body. Also, the class boundaries for different ecological quality elements were internally more consistent than those derived by the simplified mathematical boundary-setting protocol.
NASA Astrophysics Data System (ADS)
Yan, Yue; Yang, Jinzhong; Beddar, Sam; Ibbott, Geoffrey; Wen, Zhifei; Court, Laurence E.; Hwang, Ken-Pin; Kadbi, Mo; Krishnan, Sunil; Fuller, Clifton D.; Frank, Steven J.; Yang, James; Balter, Peter; Kudchadker, Rajat J.; Wang, Jihong
2018-04-01
We developed a novel technique to study the impact of geometric distortion of magnetic resonance imaging (MRI) on intensity-modulated radiation therapy treatment planning. The measured 3D datasets of residual geometric distortion (a 1.5 T MRI component of an MRI linear accelerator system) was fitted with a second-order polynomial model to map the spatial dependence of geometric distortions. Then the geometric distortion model was applied to computed tomography (CT) image and structure data to simulate the distortion of MRI data and structures. Fourteen CT-based treatment plans were selected from patients treated for gastrointestinal, genitourinary, thoracic, head and neck, or spinal tumors. Plans based on the distorted CT and structure data were generated (as the distorted plans). Dose deviations of the distorted plans were calculated and compared with the original plans to study the dosimetric impact of MRI distortion. The MRI geometric distortion led to notable dose deviations in five of the 14 patients, causing loss of target coverage of up to 3.68% and dose deviations to organs at risk in three patients, increasing the mean dose to the chest wall by up to 6.19 Gy in a gastrointestinal patient, and increases the maximum dose to the lung by 5.17 Gy in a thoracic patient.
First among Others? Cohen's "d" vs. Alternative Standardized Mean Group Difference Measures
ERIC Educational Resources Information Center
Cahan, Sorel; Gamliel, Eyal
2011-01-01
Standardized effect size measures typically employed in behavioral and social sciences research in the multi-group case (e.g., [eta][superscript 2], f[superscript 2]) evaluate between-group variability in terms of either total or within-group variability, such as variance or standard deviation--that is, measures of dispersion about the mean. In…
Using Group Projects to Assess the Learning of Sampling Distributions
ERIC Educational Resources Information Center
Neidigh, Robert O.; Dunkelberger, Jake
2012-01-01
In an introductory business statistics course, student groups used sample data to compare a set of sample means to the theoretical sampling distribution. Each group was given a production measurement with a population mean and standard deviation. The groups were also provided an excel spreadsheet with 40 sample measurements per week for 52 weeks…
Third molar development by measurements of open apices in an Italian sample of living subjects.
De Luca, Stefano; Pacifici, Andrea; Pacifici, Luciano; Polimeni, Antonella; Fischetto, Sara Giulia; Velandia Palacio, Luz Andrea; Vanin, Stefano; Cameriere, Roberto
2016-02-01
The aim of this study is to analyse the age-predicting performance of third molar index (I3M) in dental age estimation. A multiple regression analysis was developed with chronological age as the independent variable. In order to investigate the relationship between the I3M and chronological age, the standard deviation and relative error were examined. Digitalized orthopantomographs (OPTs) of 975 Italian healthy subjects (531 female and 444 male), aged between 9 and 22 years, were studied. Third molar development was determined according to Cameriere et al. (2008). Analysis of covariance (ANCOVA) was applied to study the interaction between I3M and the gender. The difference between age and third molar index (I3M) was tested with Pearson's correlation coefficient. The I3M, the age and the gender of the subjects were used as predictive variable for age estimation. The small F-value for the gender (F = 0.042, p = 0.837) reveals that this factor does not affect the growth of the third molar. Adjusted R(2) (AdjR(2)) was used as parameter to define the best fitting function. All the regression models (linear, exponential, and polynomial) showed a similar AdjR(2). The polynomial (2nd order) fitting explains about the 78% of the total variance and do not add any relevant clinical information to the age estimation process from the third molar. The standard deviation and relative error increase with the age. The I3M has its minimum in the younger group of studied individuals and its maximum in the oldest ones, indicating that its precision and reliability decrease with the age. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
A Simple Model Predicting Individual Weight Change in Humans
Thomas, Diana M.; Martin, Corby K.; Heymsfield, Steven; Redman, Leanne M.; Schoeller, Dale A.; Levine, James A.
2010-01-01
Excessive weight in adults is a national concern with over 2/3 of the US population deemed overweight. Because being overweight has been correlated to numerous diseases such as heart disease and type 2 diabetes, there is a need to understand mechanisms and predict outcomes of weight change and weight maintenance. A simple mathematical model that accurately predicts individual weight change offers opportunities to understand how individuals lose and gain weight and can be used to foster patient adherence to diets in clinical settings. For this purpose, we developed a one dimensional differential equation model of weight change based on the energy balance equation is paired to an algebraic relationship between fat free mass and fat mass derived from a large nationally representative sample of recently released data collected by the Centers for Disease Control. We validate the model's ability to predict individual participants’ weight change by comparing model estimates of final weight data from two recent underfeeding studies and one overfeeding study. Mean absolute error and standard deviation between model predictions and observed measurements of final weights are less than 1.8 ± 1.3 kg for the underfeeding studies and 2.5 ± 1.6 kg for the overfeeding study. Comparison of the model predictions to other one dimensional models of weight change shows improvement in mean absolute error, standard deviation of mean absolute error, and group mean predictions. The maximum absolute individual error decreased by approximately 60% substantiating reliability in individual weight change predictions. The model provides a viable method for estimating individual weight change as a result of changes in intake and determining individual dietary adherence during weight change studies. PMID:24707319
Fracture of mandibular condyle—to open or not to open: an attempt to settle the controversy.
Rastogi, Sanjay; Sharma, Siddharth; Kumar, Sanjeev; Reddy, Mahendra P; Niranjanaprasad Indra, B
2015-06-01
To compare the outcome of the open method versus the closed method of treatment for mandibular condylar fracture. Fifty patients with fractures of the mandibular condylar processes were evaluated. All fractures were displaced, with a degree of deviation between the condylar fragment and the ascending ramus of 10 to 45 degrees (mediolaterally). The patients were randomly divided into two groups, with group 1 receiving open reduction internal fixation and group 2 receiving closed reduction. The follow-up was done over the period of 6 months. Statistically significant improvement was seen in group 1 compared with group 2 in terms of anatomic reduction of the condyle, shortening of the ascending ramus, occlusal status, and deviation on mouth opening. A statistically significant difference was seen in the patients treated with the open method, with improved temporomandibular joint functions and fewer short- and long-term complications compared with those treated with the closed method. Copyright © 2015 Elsevier Inc. All rights reserved.
Viana, Celiana Figueiredo; Pradella-Hallinan, Márcia; Quadros, Abrahão Augusto Juviniano; Marin, Luis Fabiano; Oliveira, Acary Souza Bulle
2013-07-01
It was to evaluate the degree of fatigue in patients with paralytic poliomyelitis (PP) and with post-polio syndrome (PPS), and correlate it with parameters of sleep and the circadian cycle. Thirty patients, 17 female (56.7%), participated in the study: they answered the Revised Piper Fatigue Scale and performed a nocturnal polysomnographic study. Eleven had PP (mean age±standard deviation of 47.9±6.4 years), and 19 had PPS (mean age±standard deviation of 46.4±5.6 years). Our study showed that fatigue was worse in the afternoon in the PP Group and had a progressive increase throughout the day in the PPS Group. We also observed compromised quality of sleep in both groups, but no statically significant difference was found in the sleep parameters measured by polysomnography. Fatigue has a well-defined circadian variation, especially in PPS Group. Poor sleep quality is associated with fatigue and, therefore, sleep disturbances should be evaluated and treated in this group of PPS.
The relation of motion sickness to the spatial-temporal properties of velocity storage
NASA Technical Reports Server (NTRS)
Dai, Mingjia; Kunin, Mikhail; Raphan, Theodore; Cohen, Bernard; Young, L. R. (Principal Investigator)
2003-01-01
Tilting the head in roll to or from the upright while rotating at a constant velocity (roll while rotating, RWR) alters the position of the semicircular canals relative to the axis of rotation. This produces vertical and horizontal nystagmus, disorientation, vertigo, and nausea. With recurrent exposure, subjects habituate and can make more head movements before experiencing overpowering motion sickness. We questioned whether promethazine lessened the vertigo or delayed the habituation, whether habituation of the vertigo was related to the central vestibular time constant, i.e., to the time constant of velocity storage, and whether the severity of the motion sickness was related to deviation of the axis of eye velocity from gravity. Sixteen subjects received promethazine and placebo in a double-blind, crossover study in two consecutive 4-day test series 1 month apart, termed series I and II. Horizontal and vertical eye movements were recorded with video-oculography while subjects performed roll head movements of approx. 45 degrees over 2 s to and from the upright position while being rotated at 138 degrees /s around a vertical axis. Motion sickness was scaled from 1 (no sickness) to an endpoint of 20, at which time the subject was too sick to continue or was about to vomit. Habituation was determined by the number of head movements that subjects made before reaching the maximum motion sickness score of 20. Head movements increased steadily in each session with repeated testing, and there was no difference between the number of head movements made by the promethazine and placebo groups. Horizontal and vertical angular vestibulo-ocular reflex (aVOR) time constants declined in each test, with the declines being closely correlated to the increase in the number of head movements. The strength of vertiginous sensation was associated with the amount of deviation of the axis of eye velocity from gravity; the larger the deviation of the eye velocity axis from gravity, the more severe the motion sickness. Thus, promethazine neither reduced the nausea associated with RWR, nor retarded or hastened habituation. The inverse relationship between the aVOR time constants and number of head movements to motion sickness, and the association of the severity of motion sickness with the extent, strength, and time of deviation of eye velocity from gravity supports the postulate that the spatiotemporal properties of velocity storage, which are processed between the nodulus and uvula of the vestibulocerebellum and the vestibular nuclei, are likely to represent the source of the conflict responsible for producing motion sickness.
Digital vs. conventional full-arch implant impressions: a comparative study.
Amin, Sarah; Weber, Hans Peter; Finkelman, Matthew; El Rafie, Khaled; Kudara, Yukio; Papaspyridakos, Panos
2017-11-01
To test whether or not digital full-arch implant impressions with two different intra-oral scanners (CEREC Omnicam and True Definition) have the same accuracy as conventional ones. The hypothesis was that the splinted open-tray impressions would be more accurate than digital full-arch impressions. A stone master cast representing an edentulous mandible using five internal connection implant analogs (Straumann Bone Level RC, Basel, Switzerland) was fabricated. The three median implants were parallel to each other, the far left implant had 10°, and the far right had 15° distal angulation. A splinted open-tray technique was used for the conventional polyether impressions (n = 10) for Group 1. Digital impressions (n = 10) were taken with two intra-oral optical scanners (CEREC Omnicam and 3M True Definition) after connecting polymer scan bodies to the master cast for groups 2 and 3. Master cast and conventional impression test casts were digitized with a high-resolution reference scanner (Activity 880 scanner; Smart Optics, Bochum, Germany) to obtain digital files. Standard tessellation language (STL) datasets from the three test groups of digital and conventional impressions were superimposed with the STL dataset from the master cast to assess the 3D deviations. Deviations were recorded as root-mean-square error. To compare the master cast with conventional and digital impressions at the implant level, Welch's F-test was used together with Games-Howell post hoc test. Group I had a mean value of 167.93 μm (SD 50.37); Group II (Omnicam) had a mean value of 46.41 μm (SD 7.34); Group III (True Definition) had a mean value of 19.32 μm (SD 2.77). Welch's F-test was used together with the Games-Howell test for post hoc comparisons. Welch's F-test showed a significant difference between the groups (P < 0.001). The Games-Howell test showed statistically significant 3D deviations for all three groups (P < 0.001). Full-arch digital implant impressions using True Definition scanner and Omnicam were significantly more accurate than the conventional impressions with the splinted open-tray technique. Additionally, the digital impressions with the True Definition scanner had significantly less 3D deviations when compared with the Omnicam. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Jain, Veena; Mathur, Vijay Prakash; Kumar, Abhishek
2013-01-01
The objective of the study was to investigate whether moderate-to-severe attrition is associated with maximum bite force in the first molar region. Maximum bite force in the first molar region was measured for a total of 60 subjects having moderate-to-severe attrition of occlusal surface (experimental group) using a specially-designed piezoelectric sensor based bite force measuring device. An equal number of age, gender, height and weight matched controls (control group) were also subjected to bite force measurement for comparison. The maximum bite force was found to be significantly lower (p < 0.05) in the experimental group [480.32 (153.40)] as compared to the controls [640.63 (148.90)]. While analyzing the possible etiology for occlusal wear mainly two reasons were elicited, i.e. history of parafunctional habits like use of known abrasive tooth powder (sub-group A) and Bruxism (sub-group B). However, there were many subjects in which no known definite etiological factors be attributed to occlusal wear (sub-group C). On analysing further with respect to the possibly correlated etiological factors with maximum bite force, no significant difference was found within the experimental sub-group. However, all three experimental sub-groups had significantly lower maximum bite force as compared to age, gender and BMI matched controls. A significantly lower maximum bite force was found to be associated with moderate-to-severe attrition as compared to subjects without attrition. However, no specific relation could be found between bite force and possible etiological factors like history of parafunctional habits, history of use of known abrasive tooth powder, etc.
Scanning laser polarimetry in eyes with exfoliation syndrome.
Dimopoulos, Antonios T; Katsanos, Andreas; Mikropoulos, Dimitrios G; Giannopoulos, Theodoros; Empeslidis, Theodoros; Teus, Miguel A; Holló, Gábor; Konstas, Anastasios G P
2013-01-01
To compare retinal nerve fiber layer thickness (RNFLT) of normotensive eyes with exfoliation syndrome (XFS) and healthy eyes. Sixty-four consecutive individuals with XFS and normal office-time intraocular pressure (IOP) and 72 consecutive healthy controls were prospectively enrolled for a cross-sectional analysis in this hospital-based observational study. The GDx-VCC parameters (temporal-superior-nasal-inferior-temporal [TSNIT] average, superior average, inferior average, TSNIT standard deviation (SD), and nerve fiber indicator [NFI]) were compared between groups. Correlation between various clinical parameters and RNFLT parameters was investigated with Spearman coefficient. The NFI, although within normal limits for both groups, was significantly greater in the XFS group compared to controls: the respective median and interquartile range (IQR) values were 25.1 (22.0-29.0) vs 15.0 (12.0-20.0), p<0.001. In the XFS group, all RNFLT values were significantly lower compared to controls (p<0.001). However, they were all within the normal clinical ranges for both groups: TSNIT average median (IQR): 52.8 (49.7-55.7) vs 56.0 (53.0-59.3) µm; superior average mean (SD): 62.3 (6.7) vs 68.8 (8.2) µm; inferior average mean (SD): 58.0 (7.2) vs 64.8 (7.7) µm, respectively. TSNIT SD was significantly lower in the XFS group, median (IQR): 18.1 (15.4-20.4) vs 21.0 (18.4-23.8), p<0.001. There was no systematic relationship between RNFLT and visual acuity, cup-to-disc ratio, IOP, central corneal thickness, Humphrey mean deviation, and pattern standard deviation in either group. Compared to control eyes, polarimetry-determined RNFLT was lower in XFS eyes with normal IOP. Therefore, close monitoring of RNFLT may facilitate early identification of those XFS eyes that convert to exfoliative glaucoma.
Xiong, F; Yang, F; Huo, T Z; Li, P; Mao, M
2014-01-01
As the intrauterine environment can effect children's growth and development, this study aimed to explore the relationship between birth high-risk and physique situation of 9 to 15-year-old children by cross-sectional investigation, and to provide clues for the monitoring, prevention, and treatment of growth deviation in children. This study recruited 7,194 students aged 9 to 15 years in primary and junior schools. Their parents were asked to complete the birth situation questionnaire. Measurements included height, weight, and body mass index (BMI). Birth high-risk infant was defined according to the gestational age and birth weight. Growth deviation was classified as underweight, short stature, overweight, and obesity. The prevalence of all kinds of growth deviations in preterm, full-term, and post-term birth groups were similar, the same as the physique situation at school age among both sexes. The incidence of small for gestational age (SGA) was 6.23%, when at school age, part of SGA had catch-up growth. However, the prevalence of underweight and short stature for SGA was highest in three groups. The weight and height at school age in SGA group was less than that in appropriate for gestational age (AGA) and large for gestational age (LGA) groups. The prevalence of overweight and obesity for LGA and macrosomia were highest in three groups. At school age, the weight in macrosomia and LGA groups was higher than that in the other groups. Longitudinal height and weight development and growth of children with birth high-risk are different from normal children. In order to improve healthy situation, more attention should be paid to height and weight development of those children with birth high-risk at school age, even in pre-school age. Prevention may already begin during pregnancy.
A randomized intervention trial to reduce mechanical exposures in the Colombian flower industry.
Barrero, L H; Ceballos, C; Ellegast, R; Pulido, J A; Monroy, M; Berrio, S; Quintana, L A
2014-01-01
Evidence on effectiveness of ergonomic interventions to reduce mechanical demands of the upper extremity is scarce in agriculture. To conduct an ergonomic intervention to reduce mechanical exposures on workers during manual flower cutting, while emphasizing postural education and reduction of force requirements. Seventy seven workers (20 to 55 years old; 80% women) from six companies that cultivate roses participated in this study. Participants from three companies were randomly assigned to control and intervention groups. A postural education program and a maintenance program was designed and implemented in the intervention group aiming to achieve more neutral postures of the wrist and forearm and to reduce force requirements during rose cutting. Changes in self-reported effort and upper extremity postures, kinematics and muscular activity between baseline and follow-up assessments were evaluated. Most of the observed changes in the evaluated mechanical exposures were moderate for both groups. The intervention group showed differential improvements compared to the control group for 95th percentile forearm pronation (intervention group went from 50.6 to 35.6°; control group went from 18.4 to 34.7°); and to some degree for the maximum wrist radial deviation (the intervention group went from 17° to 7.6°; control group went from 10.1° to 7.8°). Also, the mean elbow flexion for the control group was reduced from 62.3 to 48.4°, whereas it increased from 52.2 to 57.3° in the intervention group. No differential changes between the intervention and control groups were observed for the kinematic variables, except for an unexpected reduction in the 95th percentile velocity of wrist flexion-extension in the control group, which was not observed in the intervention group. Lastly, although observed changes in muscular activity were not statistically significant, improvements were observed for the intervention group for the flexor and extensor carpi radialis and the flexor carpi ulnaris; although the opposite was true for the extensor carpi ulnaris. Important although sometimes mixed results were achieved with this field intervention, focusing on postural and force requirement demands. The positive results are encouraging considering the presence of typical limitations observed in field intervention studies.
Effect of shoulder girdle strengthening on trunk alignment in patients with stroke.
Awad, Amina; Shaker, Hussien; Shendy, Wael; Fahmy, Manal
2015-07-01
[Purpose] This study investigated the effect of shoulder girdle strengthening, particularly the scapular muscles, on poststroke trunk alignment. [Subjects and Methods] The study involved 30 patients with residual hemiparesis following cerebrovascular stroke. Patient assessment included measuring shoulder muscle peak torque, scapular muscles peak force, spinal lateral deviation angle, and motor functional performance. Patients were randomly allocated either to the control group or the study group and received an 18-session strengthening program including active resisted exercises for shoulder abductors and external rotators in addition to trunk control exercises. The study group received additional strengthening exercises for the scapular muscles. [Results] The two groups showed significant improvement in strength of all shoulder and scapular muscles, with higher improvement in the study group. Similarly, the lateral spinal deviation angles significantly improved in both groups, with significantly higher improvement in the study group. Transfer activity, sitting balance, upper limb functions, and hand movements significantly improved in the two groups, with higher improvement in the latter two functions in the study group. [Conclusion] Strengthening of shoulder girdle muscles, particularly scapular muscles, can significantly contribute to improving the postural alignment of the trunk in patients with poststroke hemiparesis.
Ishida, Kazunari; Shibanuma, Nao; Matsumoto, Tomoyuki; Sasaki, Hiroshi; Takayama, Koji; Matsuzaki, Tokio; Tei, Katsumasa; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-01-01
To investigate whether intraoperative kinematics obtained by navigation systems can be divided into several kinematic patterns and to assess the correlation between the intraoperative kinematics with maximum flexion angles before and after total knee arthroplasty (TKA). Fifty-four posterior-stabilised (PS) TKA implanted using an image-free navigation system were evaluated. At registration and after implantation, tibial internal rotation angles at maximum extension, 30°, 45°, 60°, 90°, and maximum flexion were collected. The rotational patterns were divided into four groups and were examined the correlation with maximum flexion before and after operation. Tibial internal rotation from 90° of flexion to maximum flexion at registration was correlated with maximum flexion angles pre- and postoperatively. The four groups showed statistically different kinematic patterns. The group with tibial external rotation up to 90° of flexion, following tibial internal rotation at registration, achieved better flexion angles, compared to those of another groups (126.7° ± 12.0°, p < 0.05). The group with tibial external rotation showed the worst flexion angles (80.0° ± 40.4°, p < 0.05). Furthermore, the group with limited extension showed worse flexion angles (111.6° ± 8.9°, p < 0.05). Navigation-based kinematic patterns found at registration predict postoperative maximum flexion angle in PS TKA. Navigation-based kinematics can be useful information during TKA surgery. Diagnostic studies, development of diagnostic criteria in a consecutive series of patients and a universally applied "gold" standard, Level II.
CT differentiation of 1-2-cm gallbladder polyps: benign vs malignant.
Song, E Rang; Chung, Woo-Suk; Jang, Hye Young; Yoon, Minjae; Cha, Eun Jung
2014-04-01
To evaluate MDCT findings of 1-2-cm sized gallbladder (GB) polyps for differentiation between benign and malignant polyps. Institutional review board approval was obtained, and informed consent was waived. Portal venous phase CT scans of 1-2-cm sized GB polyps caused by various pathologic conditions were retrospectively reviewed by two blinded observers. Among the 36 patients identified, 21 had benign polyps with the remaining 15 having malignant polyps. Size, margin, and shape of GB polyps were evaluated. Attenuation values of the polyps, including mean attenuation, maximum attenuation, and standard deviation, were recorded. As determined by visual inspection, the degree of polyp enhancement was evaluated. Using these CT findings, each of the two radiologists assessed and recorded individual diagnostic confidence for differentiating benign versus malignant polyps on a 5-point scale. The diagnostic performance of CT was evaluated using a receiver operating characteristic curve analysis. There was no significant difference in size between benign and malignant GB polyps. Ill-defined margin and sessile morphology were significantly associated with malignant polyp. There was a significant difference in mean and maximum attenuation values between benign and malignant GB polyps. Mean standard deviation value of malignant polyps was significantly higher than that of benign polyps. All malignant polyps showed either hyperenhancement or marked hyperenhancement. A z value for the diagnosis of malignant GB polyps was 0.905. Margin, shape, and enhancement degree are helpful in differentiating between benign and malignant polyps of 1-2-cm sizes.
NASA Astrophysics Data System (ADS)
Li, Qimeng; Li, Shichun; Hu, Xianglong; Zhao, Jing; Xin, Wenhui; Song, Yuehui; Hua, Dengxin
2018-01-01
The absolute measurement technique for atmospheric temperature can avoid the calibration process and improve the measurement accuracy. To achieve the rotational Raman temperature lidar of absolute measurement, the two-stage parallel multi-channel spectroscopic filter combined a first-order blazed grating with a fiber Bragg grating is designed and its performance is tested. The parameters and the optical path structure of the core cascaded-device (micron-level fiber array) are optimized, the optical path of the primary spectroscope is simulated and the maximum centrifugal distortion of the rotational Raman spectrum is approximately 0.0031 nm, the centrifugal ratio of 0.69%. The experimental results show that the channel coefficients of the primary spectroscope are 0.67, 0.91, 0.67, 0.75, 0.82, 0.63, 0.87, 0.97, 0.89, 0.87 and 1 by using the twelfth channel as a reference and the average FWHM is about 0.44 nm. The maximum deviation between the experimental wavelength and the theoretical value is approximately 0.0398 nm, with the deviation degree of 8.86%. The effective suppression to elastic scattering signal are 30.6, 35.2, 37.1, 38.4, 36.8, 38.2, 41.0, 44.3, 44.0, 46.7 dB. That means, combined with the second spectroscope, the suppression at least is up to 65 dB. Therefore we can fine extract single rotational Raman line to achieve the absolute measurement technique.
Stress transfer mechanisms at the submicron level for graphene/polymer systems.
Anagnostopoulos, George; Androulidakis, Charalampos; Koukaras, Emmanuel N; Tsoukleri, Georgia; Polyzos, Ioannis; Parthenios, John; Papagelis, Konstantinos; Galiotis, Costas
2015-02-25
The stress transfer mechanism from a polymer substrate to a nanoinclusion, such as a graphene flake, is of extreme interest for the production of effective nanocomposites. Previous work conducted mainly at the micron scale has shown that the intrinsic mechanism of stress transfer is shear at the interface. However, since the interfacial shear takes its maximum value at the very edge of the nanoinclusion it is of extreme interest to assess the effect of edge integrity upon axial stress transfer at the submicron scale. Here, we conduct a detailed Raman line mapping near the edges of a monolayer graphene flake that is simply supported onto an epoxy-based photoresist (SU8)/poly(methyl methacrylate) matrix at steps as small as 100 nm. We show for the first time that the distribution of axial strain (stress) along the flake deviates somewhat from the classical shear-lag prediction for a region of ∼ 2 μm from the edge. This behavior is mainly attributed to the presence of residual stresses, unintentional doping, and/or edge effects (deviation from the equilibrium values of bond lengths and angles, as well as different edge chiralities). By considering a simple balance of shear-to-normal stresses at the interface we are able to directly convert the strain (stress) gradient to values of interfacial shear stress for all the applied tensile levels without assuming classical shear-lag behavior. For large flakes a maximum value of interfacial shear stress of 0.4 MPa is obtained prior to flake slipping.
Heyland, Mark; Trepczynski, Adam; Duda, Georg N; Zehn, Manfred; Schaser, Klaus-Dieter; Märdian, Sven
2015-12-01
Selection of boundary constraints may influence amount and distribution of loads. The purpose of this study is to analyze the potential of inertia relief and follower load to maintain the effects of musculoskeletal loads even under large deflections in patient specific finite element models of intact or fractured bone compared to empiric boundary constraints which have been shown to lead to physiological displacements and surface strains. The goal is to elucidate the use of boundary conditions in strain analyses of bones. Finite element models of the intact femur and a model of clinically relevant fracture stabilization by locking plate fixation were analyzed with normal walking loading conditions for different boundary conditions, specifically re-balanced loading, inertia relief and follower load. Peak principal cortex surface strains for different boundary conditions are consistent (maximum deviation 13.7%) except for inertia relief without force balancing (maximum deviation 108.4%). Influence of follower load on displacements increases with higher deflection in fracture model (from 3% to 7% for force balanced model). For load balanced models, follower load had only minor influence, though the effect increases strongly with higher deflection. Conventional constraints of fixed nodes in space should be carefully reconsidered because their type and position are challenging to justify and for their potential to introduce relevant non-physiological reaction forces. Inertia relief provides an alternative method which yields physiological strain results. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Başkan, Ceyda; Köz, Özlem G; Duman, Rahmi; Gökçe, Sabite E; Yarangümeli, Ahmet A; Kural, Gülcan
2016-12-01
The purpose of this study is to examine the demographics, clinical properties, and the relation between white-on-white standard automated perimetry (SAP), short wavelength automated perimetry (SWAP), and optical coherence tomographic (OCT) parameters of patients with ocular hypertension. Sixty-one eyes of 61 patients diagnosed with ocular hypertension in the Ankara Numune Education and Research Hospital ophthalmology unit between January 2010 and January 2011 were included in this study. All patients underwent SAP and SWAP tests with the Humphrey visual field analyser using the 30.2 full-threshold test. Retinal nerve fiber layers (RNFL) and optic nerve heads of patients were evaluated with Stratus OCT. Positive correlation was detected between SAP pattern standard deviation value and average intraocular pressure (P=0.017), maximum intraocular pressure (P=0.009), and vertical cup to disc (C/D) ratio (P=0.009). Positive correlation between SWAP median deviation value with inferior (P=0.032), nasal (P=0.005), 6 o'clock quadrant RNFL thickness (P=0.028), and Imax/Tavg ratio (P=0.023) and negative correlation with Smax/Navg ratio (P=0.005) were detected. There was no correlation between central corneal thickness and peripapillary RNFL thicknesses (P>0.05). There was no relation between SAP median deviation, pattern standard deviation values and RNFL thicknesses and optic disc parameters of the OCT. By contrast significant correlation between several SWAP parameters and OCT parameters were detected. SWAP appeared to outperform achromatic SAP when the same 30-2 method was used.
A visual tristimulus projection colorimeter.
Valberg, A
1971-01-01
Based on the optical principle of a slide projector, a visual tristimulus projection colorimeter has been developed. The calorimeter operates with easily interchangeable sets of primary color filters placed in a frame at the objective. The apparatus has proved to be fairly accurate. The reproduction of the color matches as measured by the standard deviation is equal to the visual sensitivity to color differences for each observer. Examples of deviations in the matches among individuals as well as deviations compared with the CIE 1931 Standard Observer are given. These deviations are demonstrated to be solely due to individual differences in the perception of metameric colors. Thus, taking advantage of an objective observation (allowing all adjustments to be judged by a group of impartial observers), the colorimeter provides an excellent aid in the study of discrimination, metamerism, and related effects which are of considerable interest in current research in colorimetry and in the study of color vision tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matyushichev, V.B.; Taratukhin, V.R.; Shamratova, V.G.
1978-01-01
The effectiveness of exposing rats to different doses of x radiation after submitting them to a heat load, according to the tests of ATPase and creatine kinase activity of aqueous extracts of skin at the relatively late observation period was compared. The effects of the combined factors were monitored by means of a heat load (one group) and exposure to radiation alone in doses of 25, 50, 100, 250, and 400 R (5 groups). The obtained data are indicative of marked specificity of ATPase and creatine kinase reactions to the combined factors. Creatine kinase activity undergoes a 157% change, whereasmore » the mean relative deviation of ATPase activity constitutes only 71% of the normal level. The most effect loads are 36/sup 0/C + 25 R and 36/sup 0/C + 400 R. With all tested doses the extent of the effect of radiation on creatine kinase activity is only negligibly lower than the effectiveness of combined loads, whereas according to the ATPase test, radiation alone induces virtually the same changes in activity as combined factors. ATPase undergoes maximum change after irradiation in doses of 250 and 400 R; delivery of 25 to 100 R is associated with much less marked changes in activity. In contrast, creatine kinase demonstrates maximum sensitivity to radiation in a dosage of 25 R and minimum sensitivity, with a dosage of 100 R. Thermal stress (according to ATPase and creatine kinase activity) has a profound and quite substantial effect on processes of development of radiation lesion. It can be manifested by complete or partial summation of effects of each of the factors, mutual attenuation of effects, or absence of interaction between factors in the combination. All this is indicative of the complexity and differences in mechanisms of expression of effects of the factors used. (ERB)« less
Alcohol consumption for simulated driving performance: A systematic review.
Rezaee-Zavareh, Mohammad Saeid; Salamati, Payman; Ramezani-Binabaj, Mahdi; Saeidnejad, Mina; Rousta, Mansoureh; Shokraneh, Farhad; Rahimi-Movaghar, Vafa
2017-06-01
Alcohol consumption can lead to risky driving and increase the frequency of traffic accidents, injuries and mortalities. The main purpose of our study was to compare simulated driving performance between two groups of drivers, one consumed alcohol and the other not consumed, using a systematic review. In this systematic review, electronic resources and databases including Medline via Ovid SP, EMBASE via Ovid SP, PsycINFO via Ovid SP, PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINHAL) via EBSCOhost were comprehensively and systematically searched. The randomized controlled clinical trials that compared simulated driving performance between two groups of drivers, one consumed alcohol and the other not consumed, were included. Lane position standard deviation (LPSD), mean of lane position deviation (MLPD), speed, mean of speed deviation (MSD), standard deviation of speed deviation (SDSD), number of accidents (NA) and line crossing (LC) were considered as the main parameters evaluating outcomes. After title and abstract screening, the articles were enrolled for data extraction and they were evaluated for risk of biases. Thirteen papers were included in our qualitative synthesis. All included papers were classified as high risk of biases. Alcohol consumption mostly deteriorated the following performance outcomes in descending order: SDSD, LPSD, speed, MLPD, LC and NA. Our systematic review had troublesome heterogeneity. Alcohol consumption may decrease simulated driving performance in alcohol consumed people compared with non-alcohol consumed people via changes in SDSD, LPSD, speed, MLPD, LC and NA. More well-designed randomized controlled clinical trials are recommended. Copyright © 2017. Production and hosting by Elsevier B.V.
Schmitter, Marc; Kress, Bodo; Leckel, Michael; Henschel, Volkmar; Ohlmann, Brigitte; Rammelsberg, Peter
2008-06-01
This hypothesis-generating study was performed to determine which items in the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) and additional diagnostic tests have the best predictive accuracy for joint-related diagnoses. One hundred forty-nine TMD patients and 43 symptom-free subjects were examined in clinical examinations and with magnetic resonance imaging (MRI). The importance of each variable of the clinical examination for correct joint-related diagnosis was assessed by using MRI diagnoses. For this purpose, "random forest" statistical software (based on classification trees) was used. Maximum unassisted jaw opening, maximum assisted jaw opening, history of locked jaw, joint sound with and without compression, joint pain, facial pain, pain on palpation of the lateral pterygoid area, and overjet proved suitable for distinguishing between subtypes of joint-related TMD. Measurement of excursion, protrusion, and midline deviation were less important. The validity of clinical TMD examination procedures can be enhanced by using the 16 variables of greatest importance identified in this study. In addition to other variables, maximum unassisted and assisted opening and a history of locked jaw were important when assessing the status of the TMJ.
2015-01-01
The goal of this study was to analyse perceptually and acoustically the voices of patients with Unilateral Vocal Fold Paralysis (UVFP) and compare them to the voices of normal subjects. These voices were analysed perceptually with the GRBAS scale and acoustically using the following parameters: mean fundamental frequency (F0), standard-deviation of F0, jitter (ppq5), shimmer (apq11), mean harmonics-to-noise ratio (HNR), mean first (F1) and second (F2) formants frequency, and standard-deviation of F1 and F2 frequencies. Statistically significant differences were found in all of the perceptual parameters. Also the jitter, shimmer, HNR, standard-deviation of F0, and standard-deviation of the frequency of F2 were statistically different between groups, for both genders. In the male data differences were also found in F1 and F2 frequencies values and in the standard-deviation of the frequency of F1. This study allowed the documentation of the alterations resulting from UVFP and addressed the exploration of parameters with limited information for this pathology. PMID:26557690
Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A
1980-12-01
1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.
Georg, Dietmar; Stock, Markus; Kroupa, Bernhard; Olofsson, Jörgen; Nyholm, Tufve; Ahnesjö, Anders; Karlsson, Mikael
2007-08-21
Experimental methods are commonly used for patient-specific intensity-modulated radiotherapy (IMRT) verification. The purpose of this study was to investigate the accuracy and performance of independent dose calculation software (denoted as 'MUV' (monitor unit verification)) for patient-specific quality assurance (QA). 52 patients receiving step-and-shoot IMRT were considered. IMRT plans were recalculated by the treatment planning systems (TPS) in a dedicated QA phantom, in which an experimental 1D and 2D verification (0.3 cm(3) ionization chamber; films) was performed. Additionally, an independent dose calculation was performed. The fluence-based algorithm of MUV accounts for collimator transmission, rounded leaf ends, tongue-and-groove effect, backscatter to the monitor chamber and scatter from the flattening filter. The dose calculation utilizes a pencil beam model based on a beam quality index. DICOM RT files from patient plans, exported from the TPS, were directly used as patient-specific input data in MUV. For composite IMRT plans, average deviations in the high dose region between ionization chamber measurements and point dose calculations performed with the TPS and MUV were 1.6 +/- 1.2% and 0.5 +/- 1.1% (1 S.D.). The dose deviations between MUV and TPS slightly depended on the distance from the isocentre position. For individual intensity-modulated beams (total 367), an average deviation of 1.1 +/- 2.9% was determined between calculations performed with the TPS and with MUV, with maximum deviations up to 14%. However, absolute dose deviations were mostly less than 3 cGy. Based on the current results, we aim to apply a confidence limit of 3% (with respect to the prescribed dose) or 6 cGy for routine IMRT verification. For off-axis points at distances larger than 5 cm and for low dose regions, we consider 5% dose deviation or 10 cGy acceptable. The time needed for an independent calculation compares very favourably with the net time for an experimental approach. The physical effects modelled in the dose calculation software MUV allow accurate dose calculations in individual verification points. Independent calculations may be used to replace experimental dose verification once the IMRT programme is mature.
Al-Ekrish, Asma'a A; Alfadda, Sara A; Ameen, Wadea; Hörmann, Romed; Puelacher, Wolfgang; Widmann, Gerlig
2018-06-16
To compare the surface of computer-aided design (CAD) models of the maxilla produced using ultra-low MDCT doses combined with filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) reconstruction techniques with that produced from a standard dose/FBP protocol. A cadaveric completely edentulous maxilla was imaged using a standard dose protocol (CTDIvol: 29.4 mGy) and FBP, in addition to 5 low dose test protocols (LD1-5) (CTDIvol: 4.19, 2.64, 0.99, 0.53, and 0.29 mGy) reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. A CAD model from each test protocol was superimposed onto the reference model using the 'Best Fit Alignment' function. Differences between the test and reference models were analyzed as maximum and mean deviations, and root-mean-square of the deviations, and color-coded models were obtained which demonstrated the location, magnitude and direction of the deviations. Based upon the magnitude, size, and distribution of areas of deviations, CAD models from the following protocols were comparable to the reference model: FBP/LD1; ASIR 50/LD1 and LD2; ASIR 100/LD1, LD2, and LD3; MBIR/LD1. The following protocols demonstrated deviations mostly between 1-2 mm or under 1 mm but over large areas, and so their effect on surgical guide accuracy is questionable: FBP/LD2; MBIR/LD2, LD3, LD4, and LD5. The following protocols demonstrated large deviations over large areas and therefore were not comparable to the reference model: FBP/LD3, LD4, and LD5; ASIR 50/LD3, LD4, and LD5; ASIR 100/LD4, and LD5. When MDCT is used for CAD models of the jaws, dose reductions of 86% may be possible with FBP, 91% with ASIR 50, and 97% with ASIR 100. Analysis of the stability and accuracy of CAD/CAM surgical guides as directly related to the jaws is needed to confirm the results.
Dependence of Some Properties of Groups on Group Local Number Density
NASA Astrophysics Data System (ADS)
Deng, Xin-Fa; Wu, Ping
2014-09-01
In this study we investigate the dependence of projected size Sizesky, and rms deviation σR of projected distance in the sky from the group center, rms velocities σV , and virial radius RVir of groups on group local number density. In the volume-limited group samples, it is found that groups in high density regions preferentially have larger Sizesky, σR , σV , and RVir than ones in low density regions.
Cutting efficiency of instruments with different movements: a comparative study.
Tocci, Luigi; Plotino, Gianluca; Al-Sudani, Dina; Rubini, Alessio Giansiracusa; Sannino, Gianpaolo; Piasecki, Lucila; Putortì, Ermanno; Testarelli, Luca; Gambarini, Gianluca
2015-01-01
The aim of the present study was to evaluate the cutting efficiency of two new reciprocating instruments, Twisted File Adaptive and WaveOne Primary. 10 new Twisted File Adaptive (TF Adaptive) (SybronEndo, Glendora, CA, USA) and 10 new WaveOne Primary files (Dentsply Maillefer, Ballaigues, Switzerland) were activated using a torque-controlled motor, respectively TFA motor (SybronEndo, Glendora, CA, USA) and Silver motor (VDW, Munich, Germany). The device used for the cutting test consisted on a mainframe to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1 mm. Mean and standard deviations of each group were calculated and data were statistically analyzed with one-way ANOVA and Bonferroni t test (P < 0.05). TF Adaptive displayed significantly greater maximum penetration depth than WaveOne Primary (P < 0.05). In fact, TF Adaptive instruments (Group 1) cut the Plexiglas block to a mean depth of 8.7 (SD 0.5) mm, while WaveOne Primary instruments cut the Plexiglas block to a mean depth of 6.4 (SD 0.3) mm. Twisted File Adaptive instruments demonstrated statistically higher cutting efficiency than WaveOne instruments.