Sample records for groups vacuum alignment

  1. Systems and Methods for Fabricating Carbon Nanotube-Based Vacuum Electronic Devices

    NASA Technical Reports Server (NTRS)

    Manohara, Harish (Inventor); Toda, Risaku (Inventor); Del Castillo, Linda Y. (Inventor); Murthy, Rakesh (Inventor)

    2015-01-01

    Systems and methods in accordance with embodiments of the invention proficiently produce carbon nanotube-based vacuum electronic devices. In one embodiment a method of fabricating a carbon nanotube-based vacuum electronic device includes: growing carbon nanotubes onto a substrate to form a cathode; assembling a stack that includes the cathode, an anode, and a first layer that includes an alignment slot; disposing a microsphere partially into the alignment slot during the assembling of the stack such that the microsphere protrudes from the alignment slot and can thereby separate the first layer from an adjacent layer; and encasing the stack in a vacuum sealed container.

  2. Note: A simple sample transfer alignment for ultra-high vacuum systems.

    PubMed

    Tamtögl, A; Carter, E A; Ward, D J; Avidor, N; Kole, P R; Jardine, A P; Allison, W

    2016-06-01

    The alignment of ultra-high-vacuum sample transfer systems can be problematic when there is no direct line of sight to assist the user. We present the design of a simple and cheap system which greatly simplifies the alignment of sample transfer devices. Our method is based on the adaptation of a commercial digital camera which provides live views from within the vacuum chamber. The images of the camera are further processed using an image recognition and processing code which determines any misalignments and reports them to the user. Installation has proven to be extremely useful in order to align the sample with respect to the transfer mechanism. Furthermore, the alignment software can be easily adapted for other systems.

  3. Method for vacuum fusion bonding

    DOEpatents

    Ackler, Harold D.; Swierkowski, Stefan P.; Tarte, Lisa A.; Hicks, Randall K.

    2001-01-01

    An improved vacuum fusion bonding structure and process for aligned bonding of large area glass plates, patterned with microchannels and access holes and slots, for elevated glass fusion temperatures. Vacuum pumpout of all components is through the bottom platform which yields an untouched, defect free top surface which greatly improves optical access through this smooth surface. Also, a completely non-adherent interlayer, such as graphite, with alignment and location features is located between the main steel platform and the glass plate pair, which makes large improvements in quality, yield, and ease of use, and enables aligned bonding of very large glass structures.

  4. Alignment Fixtures For Vacuum-Plasma-Spray Gun

    NASA Technical Reports Server (NTRS)

    Woodford, William H.; Mckechnie, Timothy N.; Power, Christopher A.; Daniel, Ronald L., Jr.

    1993-01-01

    Fixtures for alignment of vacuum-plasma-spray guns built. Each fixture designed to fit specific gun and holds small, battery-powered laser on centerline of gun. Laser beam projects small red dot where centerline intersects surface of workpiece to be sprayed. After laser beam positioned on surface of workpiece, fixture removed from gun and spraying proceeds.

  5. Fusion bonding and alignment fixture

    DOEpatents

    Ackler, Harold D.; Swierkowski, Stefan P.; Tarte, Lisa A.; Hicks, Randall K.

    2000-01-01

    An improved vacuum fusion bonding structure and process for aligned bonding of large area glass plates, patterned with microchannels and access holes and slots, for elevated glass fusion temperatures. Vacuum pumpout of all the components is through the bottom platform which yields an untouched, defect free top surface which greatly improves optical access through this smooth surface. Also, a completely non-adherent interlayer, such as graphite, with alignment and location features is located between the main steel platform and the glass plate pair, which makes large improvements in quality, yield, and ease of use, and enables aligned bonding of very large glass structures.

  6. Enhanced Alignment Techniques for the Thomson Scattering Diagnostic on the Lithium Tokamak eXperiment (LTX)

    NASA Astrophysics Data System (ADS)

    Merino, Enrique; Kozub, Tom; Boyle, Dennis; Lucia, Matthew; Majeski, Richard; Kaita, Robert; Schmitt, John C.; Leblanc, Benoit; Diallo, Ahmed; Jacobson, C. M.

    2014-10-01

    The Thomson Scattering (TS) System in LTX is used to measure electron temperature and density profiles of core and edge plasmas. In view of TS measurements showing low signal-to-noise and high stray light, numerous improvements were performed in recent months. These will allow for better measurements. Due to the nature of LTX's lithium coated walls, a particular challenge was presented by alignment procedures which required insertion and precise positioning of equipment in the vacuum vessel without breaking vacuum. To overcome these difficulties, the laser flight tubes were removed and an alignment probe setup placed along the beam line on a differentially pumped assembly. The probe was then driven into the vacuum vessel and back-illumination of the viewing optics on it allowed for alignment and spatial calibration. Other upgrades included better bracing of flight tubes and viewing optics as well as a redesigned beam dump. An overview of these improvements will be presented. Supported by US DOE Contracts DE-AC02-09CH11466 and DE-AC52-07NA27344.

  7. Effects of vacuum exposure on stress and spectral shift of high reflective coatings

    NASA Astrophysics Data System (ADS)

    Stolz, C. J.; Taylor, J. R.; Eickelberg, W. K.; Lindh, J. D.

    1992-06-01

    The Atomic Vapor Laser Isotope Laser Separation (AVLIS) program operates the world's largest average power dye laser; the dye laser beams are combined, formatted, and transported in vacuum. The optical system is aligned at atmosphere, while the system must meet requirements in vacuum. Therefore, coating performance must be characterized in both atmosphere and vacuum. Changes in stress and spectral shift in ambient and vacuum environments are reported for conventional and dense multilayer dielectric coatings.

  8. Relay telescope for high power laser alignment system

    DOEpatents

    Dane, C. Brent; Hackel, Lloyd; Harris, Fritz B.

    2006-09-19

    A laser system includes an optical path having an intracavity relay telescope with a telescope focal point for imaging an output of the gain medium between an image location at or near the gain medium and an image location at or near an output coupler for the laser system. A kinematic mount is provided within a vacuum chamber, and adapted to secure beam baffles near the telescope focal point. An access port on the vacuum chamber is adapted for allowing insertion and removal of the beam baffles. A first baffle formed using an alignment pinhole aperture is used during alignment of the laser system. A second tapered baffle replaces the alignment aperture during operation and acts as a far-field baffle in which off angle beams strike the baffle a grazing angle of incidence, reducing fluence levels at the impact areas.

  9. Alignment Measurements of the Microwave Anisotropy Probe (MAP) Instrument in a Thermal/Vacuum Chamber

    NASA Technical Reports Server (NTRS)

    Hill, Michael D.; Herrera, Acey A.; Crane, J. Allen; Packard, Edward A.; Aviado, Carlos; Sampler, Henry P.

    2000-01-01

    The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a fall 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (approximately 0.2 degree) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back Gregorian telescopes to focus the microwave signals into 10 differential microwave receivers, via 20 feed horns. Proper alignment of the telescope reflectors and the feed horns at the operating temperature of 90 K is a critical element to ensure mission success. We describe the hardware and methods used to validate the displacement/deformation predictions of the reflectors and the microwave feed horns during thermal/vacuum testing of the reflectors and the microwave instrument. The smallest deformation predictions to be measured were on the order of +/- 0.030 inches (+/- 0.762 mm). Performance of these alignment measurements inside a thermal/vacuum chamber with conventional alignment equipment posed several limitations. The most troublesome limitation was the inability to send personnel into the chamber to perform the measurements during the test due to vacuum and the temperature extremes. The photogrammetry (PG) system was chosen to perform the measurements since it is a non- contact measurement system, the measurements can be made relatively quickly and accurately, and the photogrammetric camera can be operated remotely. The hardware and methods developed to perform the MAP alignment measurements using PG proved to be highly successful. The measurements met the desired requirements, for the metal structures enabling the desired distortions to be measured resolving deformations an order of magnitude smaller than the imposed requirements. Viable data were provided to the MAP Project for a full analysis of the on-orbit performance of the Instrument's microwave system.

  10. Alignment Measurement of the New Horizons (NH) High Gain Antenna (HGA) in the Thermal/Vacuum Chamber using Photogrammetry

    NASA Technical Reports Server (NTRS)

    Hill, Michael D.; Saulino, Helen; Troll, John; Schulze, Ron; Mehoke, Doug; Gill, James; Stergiou, Niko

    2006-01-01

    The New Horizons (NH) spacecraft, launched in January, 2006, is the first mission to explore the planet Pluto and the icy bodies at the edge of the Solar system making up the Kuiper belt. NH utilizes a shaped parabolic High Gain Antenna (HGA) to transmit and receive data over the vast 3 billion mile distance it will travel. Proper maintenance of the HGA shape and alignment at cryogenic temperatures (90 K) is a critical element to ensure mission success. We describe the hardware and methods that were used to validate the displacement/deformation predictions of the HGA reflector during thermal/vacuum testing of the HGA system. The smallest deformation predictions to be measured on the HGA were on the order of +/-0.015 inches. Measurement of the resulting change of the HGA system boresight due to the HGA deformation was also desired. Performance of these alignment measurements inside a thermal/vacuum chamber could not be performed with conventional alignment equipment, namely due to the inability to send personnel into the chamber to perform the measurements due to the temperature extremes and vacuum. The Photogrammetry (PG) system was chosen to perform the measurements since it is a non-contact measurement system, measurements can be made relatively quickly and accurately, and the camera can be operated remotely. This method had been previously proven for WMAP. The hardware and methods developed to perform the NH alignment measurements using PG proved to be successful. The measured increase in the HGA RMS surface distortion as a result of going cold was approx. 0.012 inches, indicating that the +/-0.015 inches RF requirement was met. This measured deformation resulted in a change in alignment of the HGA system boresight of less than 0.008 degrees, meeting the requirement of 0.020 degrees.

  11. Stabilization of He2(A(sup 3)Sigma(sub u)(+)) molecules in liquid helium by optical pumping for vacuum UV laser

    NASA Technical Reports Server (NTRS)

    Zmuidzinas, J. S. (Inventor)

    1978-01-01

    A technique is disclosed for achieving large populations of metastable spin-aligned He2(a 3 Sigma u +) molecules in superfluid helium to obtain lasing in the vacuum ultraviolet wavelength regime around 0.0800 micron m by electronically exciting liquid (superfluid) helium with a comparatively low-current electron beam and spin aligning the metastable molecules by means of optical pumping with a modestly-powered (100mW) circularly-polarized continuous wave laser operating at, for example, 0.9096 or 0.4650 micron m. Once a high concentration of spin-aligned He2 (a 3 Sigma u +) is achieved with lifetimes of a few milliseconds, a strong microwave signal destroys the spin alignment and induces a quick collisional transition of He2 (a 3 Sigma u +) molecules to the a 1 Sigma u + state and thereby a lasing transition to the X 1 Sigma g + state.

  12. Note: O-ring stack system for electron gun alignment.

    PubMed

    Park, In-Yong; Cho, Boklae; Han, Cheolsu; Shin, Seungmin; Lee, Dongjun; Ahn, Sang Jung

    2015-01-01

    We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignment and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.

  13. Radio Frequency Trap for Containment of Plasmas in Antimatter Propulsion Systems Using Rotating Wall Electric Fields

    NASA Technical Reports Server (NTRS)

    Sims, William Herbert, III (Inventor); Martin, James Joseph (Inventor); Lewis, Raymond A. (Inventor)

    2003-01-01

    A containment apparatus for containing a cloud of charged particles comprises a cylindrical vacuum chamber having a longitudinal axis. Within the vacuum chamber is a containment region. A magnetic field is aligned with the longitudinal axis of the vacuum chamber. The magnetic field is time invariant and uniform in strength over the containment region. An electric field is also aligned with the longitudinal axis of the vacuum chamber and the magnetic field. The electric field is time invariant, and forms a potential well over the containment region. One or more means are disposed around the cloud of particles for inducing a rotating electric field internal to the vacuum chamber. The rotating electric field imparts energy to the charged particles within the containment region and compress the cloud of particles. The means disposed around the outer surface of the vacuum chamber for inducing a rotating electric field are four or more segments forming a segmented ring, the segments conforming to the outer surface of the vacuum chamber. Each of the segments is energized by a separate alternating voltage. The sum of the voltages imposed on each segment establishes the rotating field. When four segments form a ring, the rotating field is obtained by a signal generator applying a sinusoidal signal phase delayed by 90,180 and 270 degrees in sequence to the four segments.

  14. Electronic structure of a laterally graded ZrO2-TiO2 film on Si(100) prepared by metal-organic chemical vapor deposition in ultrahigh vacuum

    NASA Astrophysics Data System (ADS)

    Richter, J. H.; Karlsson, P. G.; Sandell, A.

    2008-05-01

    A TiO2-ZrO2 film with laterally graded stoichiometry has been prepared by metal-organic chemical vapor deposition in ultrahigh vacuum. The film was characterized in situ using synchrotron radiation photoelectron spectroscopy (PES) and x-ray absorption spectroscopy. PES depth profiling clearly shows that Ti ions segregate toward the surface region when mixed with ZrO2. The binding energy of the ZrO2 electronic levels is constant with respect to the local vacuum level. The binding energy of the TiO2 electronic levels is aligned to the Fermi level down to a Ti /Zr ratio of about 0.5. At a Ti /Zr ratio between 0.1 and 0.5, the TiO2 related electronic levels become aligned to the local vacuum level. The addition of small amounts of TiO2 to ZrO2 results in a ZrO2 band alignment relative to the Fermi level that is less asymmetric than for pure ZrO2. The band edge positions shift by -0.6eV for a Ti /Zr ratio of 0.03. This is explained in terms of an increase in the work function when adding TiO2, an effect that becomes emphasized by Ti surface segregation.

  15. Relay telescope including baffle, and high power laser amplifier utilizing the same

    DOEpatents

    Dane, C. Brent; Hackel, Lloyd; Harris, Fritz B.

    2006-09-19

    A laser system includes an optical path having an intracavity relay telescope with a telescope focal point for imaging an output of the gain medium between an image location at or near the gain medium and an image location at or near an output coupler for the laser system. A kinematic mount is provided within a vacuum chamber, and adapted to secure beam baffles near the telescope focal point. An access port on the vacuum chamber is adapted for allowing insertion and removal of the beam baffles. A first baffle formed using an alignment pinhole aperture is used during alignment of the laser system. A second tapered baffle replaces the alignment aperture during operation and acts as a far-field baffle in which off angle beams strike the baffle a grazing angle of incidence, reducing fluence levels at the impact areas.

  16. Exact solutions to quadratic gravity

    NASA Astrophysics Data System (ADS)

    Pravda, V.; Pravdová, A.; Podolský, J.; Švarc, R.

    2017-04-01

    Since all Einstein spacetimes are vacuum solutions to quadratic gravity in four dimensions, in this paper we study various aspects of non-Einstein vacuum solutions to this theory. Most such known solutions are of traceless Ricci and Petrov type N with a constant Ricci scalar. Thus we assume the Ricci scalar to be constant which leads to a substantial simplification of the field equations. We prove that a vacuum solution to quadratic gravity with traceless Ricci tensor of type N and aligned Weyl tensor of any Petrov type is necessarily a Kundt spacetime. This will considerably simplify the search for new non-Einstein solutions. Similarly, a vacuum solution to quadratic gravity with traceless Ricci type III and aligned Weyl tensor of Petrov type II or more special is again necessarily a Kundt spacetime. Then we study the general role of conformal transformations in constructing vacuum solutions to quadratic gravity. We find that such solutions can be obtained by solving one nonlinear partial differential equation for a conformal factor on any Einstein spacetime or, more generally, on any background with vanishing Bach tensor. In particular, we show that all geometries conformal to Kundt are either Kundt or Robinson-Trautman, and we provide some explicit Kundt and Robinson-Trautman solutions to quadratic gravity by solving the above mentioned equation on certain Kundt backgrounds.

  17. Alignment Measurements of the Microwave Anisotropy Probe (MAP) Instrument in a Thermal/Vacuum Chamber Using Photogrammetry

    NASA Technical Reports Server (NTRS)

    Hill, Michael D.; Herrera, Acey A.; Crane, J. Allen; Packard, Edward A.; Aviado, Carlos; Sampler, Henry P.; Obenschain, Arthur (Technical Monitor)

    2000-01-01

    The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a late 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (< 0.3 deg at 90 GHz.) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back Gregorian telescopes to focus the microwave signals into 10 differential microwave receivers, via 20 feed horns. Proper alignment of the telescope reflectors and the feed horns at the operating temperature of 90 K is a critical element to ensure mission success. We describe the hardware and methods used to validate the displacement/deformation predictions of the reflectors and the microwave feed horns during thermal/vacuum testing of the reflectors and the microwave instrument. The smallest deformations to be resolved by the measurement system were on the order of +/- 0.030 inches (0.762 mm). Performance of these alignment measurements inside a thermal/vacuum chamber with conventional alignment equipment posed several limitations. A photogrammetry (PG) system was chosen to perform the measurements since it is a non-contact measurement system, the measurements can be made relatively quickly and accurately, and the photogrammetric camera can be operated remotely. The hardware and methods developed to perform the MAP alignment measurements using PG proved to be highly successful. The PG measurements met the desired requirements, enabling the desired deformations to be measured and even resolved to an order of magnitude smaller than the imposed requirements. Viable data were provided to the MAP Project for a full analysis of the on-orbit performance of the Instrument's microwave system.

  18. Mechanical Design, Simulation, and Testing of Self-Aligning Gaussian Telescope and Stand for ITER LFS Reflectometer Diagnostic

    NASA Astrophysics Data System (ADS)

    Broughton, Rachel; Gomez, Michael; Zolfaghari, Ali; Morris, Lewis

    2016-10-01

    A self-aligning Gaussian telescope has been designed to compensate for the effect of movement in the ITER vacuum vessel on the transmission line. The purpose of the setup is to couple microwaves into and out of the vessel across the vacuum windows while allowing for both slow movements of the vessel, due to thermal growth, and rapid movements, due to vibrations and disruptions. Additionally, a test stand has been designed specifically to hold this telescope in order to imitate these movements. Consequently, this will allow for the assessment of the efficacy in applying the self-aligning Gaussian telescope approach. The motions of the test stand, as well as the stress on the telescope mechanism, have been virtually simulated using ANSYS workbench. A prototype of this test stand and self-aligning telescope will be built using a combination of custom machined parts and ordered parts. The completed mechanism will be tested at the lab in four different ways: slow single- and multi-direction movements, rapid multi-direction movement, functional laser alignment and self-aligning tests, and natural frequency tests. Once the prototype successfully passes all requirements, it will be tested with microwaves in the LFSR transmission line test stand at General Atomics. This work is supported by US DOE Contract No. DE-AC02-09CH11466.

  19. Dimensional stability of flakeboards as affected by board specific gravity and flake alignment

    Treesearch

    Robert L. Geimer

    1982-01-01

    The objective was to determine the relationship between the variables specific gravity (SG) and flake alignment and the dimensional stability properties of flakeboard. Boards manufactured without a density gradient were exposed to various levels of relative humidity and a vacuum-pressure soak (VPS) treatment. Changes in moisture content (MC), thickness swelling, and...

  20. Cost-Effective Systems for Atomic Layer Deposition

    ERIC Educational Resources Information Center

    Lubitz, Michael; Medina, Phillip A., IV; Antic, Aleks; Rosin, Joseph T.; Fahlman, Bradley D.

    2014-01-01

    Herein, we describe the design and testing of two different home-built atomic layer deposition (ALD) systems for the growth of thin films with sub-monolayer control over film thickness. The first reactor is a horizontally aligned hot-walled reactor with a vacuum purging system. The second reactor is a vertically aligned cold-walled reactor with a…

  1. Delamination toughness characterization of out-of-autoclave vacuum-bag-only polymer matrix composites enhanced by z-aligned carbon nanofibers

    NASA Astrophysics Data System (ADS)

    Brewer, John S.

    Brewer, John S., M. S., University of South Alabama, May 2015. Delamination Toughness Characterization of Out-of-Autoclave Vacuum-Bag-Only Polymer Matrix Composites Enhanced by z-aligned Carbon Nanofibers. Chair of Committee: Kuang-Ting Hsiao, Ph.D. In the last few decades, the use of composite materials has revolutionized materials manufacturing. Now, carbon fiber materials are at the forefront of engineering and manufacturing technology. One of the chief failure modes of composite materials is delamination. For this reason, this study employed the Mode-I Interlaminar Fracture Toughness Test (ASTM D 5528-01) to characterize how the inclusion of z-aligned carbon nanofibers (CNF) in Carbon Fiber Reinforced Polymers (CFRP) affects delamination strength. CFRP with z-aligned CNF in concentrations of 0.3% and 0.6% by weight were compared to control CFRP samples and CFRP samples modified with 0.3 weight percent unaligned CNF. The largest improvement was seen in the 0.3 weight percent aligned composite with a mean interlaminar fracture toughness increase of over 35%, while the uncertainty was decreased. A standard deviation of 3.3% was observed which equates to an uncertainty value 30% better than the control samples. Data and microscopy are included and discussed.

  2. Critical Science Instrument Alignment of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM)

    NASA Technical Reports Server (NTRS)

    Rohrbach, Scott O.; Kubalak, David A.; Gracey, Renee M.; Sabatke, Derek S.; Howard, Joseph M.; Telfer, Randal C.; Zielinski, Thomas P.

    2016-01-01

    This paper describes the critical instrument alignment terms associated with the six-degree of freedom alignment of each the Science Instrument (SI) in the James Webb Space Telescope (JWST), including focus, pupil shear, pupil clocking, and boresight. We present the test methods used during cryogenic-vacuum tests to directly measure the performance of each parameter, the requirements levied on each, and the impact of any violations of these requirements at the instrument and Observatory level.

  3. MASS SEPARATORS

    DOEpatents

    Oppenheimer, F.; Bell, J.W.

    1959-02-17

    An improvement in the mounting arrangement for the ion source within the vacuum tank of a calutron is presented. The entire source is supported by the vacuum envelope through the medium of a bracket secured to a removable face plate. The bracket forms a supporting platform that is generally transverse to the magnetic field. The ion generator is mounted on a pedestal-type insulator supported on the bracket, and the hot leads are brought into the vacuum envelope through a tubular elbow connected to the vacuum envelope, having the axis of its outer opening aligned with the magnetic field at which point a bushing-type insulator is employed. With this arrangement thc ion source is maintained at a positive potential with respect to the vacuum tank and the problem of electron bombardment of the insulator is considerably reduced.

  4. Optical Alignment of the JWST ISIM to the OTE Simulator (OSIM): Current Concept and Design Studies

    NASA Technical Reports Server (NTRS)

    Frey, Bradley J.; Davila, Pamela S.; Marsh, James M.; Ohl, Raymond G.; Sullivan, Joseph

    2007-01-01

    The James Webb Space Telescope's (JWST) Integrated Science Instrument Module (ISIM) is the scientific payload of the observatory and contai ns four science instruments. During alignment and test of the integrated ISIM (i.e. ISIM + science instruments) at NASA's Goddard Space Fli ght Center (GSFC), the Optical telescope element SIMulator (OSIM) wil l be used to optically stimulate the science instruments to verify their operation and performance. In this paper we present the design of two cryogenic alignment fixtures that will be used to determine and verify the proper alignment of OSIM to ISIM during testing at GSFC. The se fixtures, the Master Alignment Target Fixture (MATF) and the ISIM Alignment Target Fixture (IATF), will provide continuous, 6 degree of freedom feedback to OSIM during initial ambient alignment as well as during cryogenic vacuum testing.

  5. Optical alignment of the Chromospheric Lyman-Alpha Spectro-Polarimeter using sophisticated methods to minimize activities under vacuum

    NASA Astrophysics Data System (ADS)

    Giono, G.; Katsukawa, Y.; Ishikawa, R.; Narukage, N.; Kano, R.; Kubo, M.; Ishikawa, S.; Bando, T.; Hara, H.; Suematsu, Y.; Winebarger, A.; Kobayashi, K.; Auchère, F.; Trujillo Bueno, J.

    2016-07-01

    The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument developed at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. The instrument main scientific goal is to achieve polarization measurement of the Lyman-α line at 121.56 nm emitted from the solar upper-chromosphere and transition region with an unprecedented 0.1% accuracy. The optics are composed of a Cassegrain telescope coated with a "cold mirror" coating optimized for UV reflection and a dual-channel spectrograph allowing for simultaneous observation of the two orthogonal states of polarization. Although the polarization sensitivity is the most important aspect of the instrument, the spatial and spectral resolutions of the instrument are also crucial to observe the chromospheric features and resolve the Ly-α profiles. A precise alignment of the optics is required to ensure the resolutions, but experiments under vacuum conditions are needed since Ly-α is absorbed by air, making the alignment experiments difficult. To bypass this issue, we developed methods to align the telescope and the spectrograph separately in visible light. We explain these methods and present the results for the optical alignment of the CLASP telescope and spectrograph. We then discuss the combined performances of both parts to derive the expected resolutions of the instrument, and compare them with the flight observations performed on September 3rd 2015.

  6. Graphene electron cannon: High-current edge emission from aligned graphene sheets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Jianlong; Li, Nannan; Guo, Jing

    2014-01-13

    High-current field emitters are made by graphene paper consist of aligned graphene sheets. Field emission luminance pattern shows that their electron beams can be controlled by rolling the graphene paper from sheet to cylinder. These specific electron beams would be useful to vacuum devices and electron beam lithograph. To get high-current emission, the graphene paper is rolled to array and form graphene cannon. Due to aligned emission array, graphene cannon have high emission current. Besides high emission current, the graphene cannon is also tolerable with excellent emission stability. With good field emission properties, these aligned graphene emitters bring application insight.

  7. Heterogeneous Electron-Transfer Dynamics through Dipole-Bridge Groups.

    PubMed

    Nieto-Pescador, Jesus; Abraham, Baxter; Li, Jingjing; Batarseh, Alberto; Bartynski, Robert A; Galoppini, Elena; Gundlach, Lars

    2016-01-14

    Heterogeneous electron transfer (HET) between photoexcited molecules and colloidal TiO 2 has been investigated for a set of Zn-porphyrin chromophores attached to the semiconductor via linkers that allow to change level alignment by 200 meV by reorientation of the dipole moment. These unique dye molecules have been studied by femtosecond transient absorption spectroscopy in solution and adsorbed on the TiO 2 colloidal film in vacuum. In solution energy transfer from the excited chromophore to the dipole group has been identified as a slow relaxation pathway competing with S 2 -S 1 internal conversion. On the film heterogeneous electron transfer occurred in 80 fs, much faster compared to all intramolecular pathways. Despite a difference of 200 meV in level alignment of the excited state with respect to the semiconductor conduction band, identical electron transfer times were measured for different linkers. The measurements are compared to a quantum-mechanical model that accounts for electronic-vibronic coupling and finite band width for the acceptor states. We conclude that HET occurs into a distribution of transition states that differs from regular surface states or bridge mediated states.

  8. COR1 Engineering Test Unit Measurements at the NCAR/HAO Vacuum Tunnel Facility, October-November 2002

    NASA Technical Reports Server (NTRS)

    Thompson, William

    2002-01-01

    The Engineering Test Unit (ETU) of COR1 was made in two configurations. The first configuration, ETU-1, was for vibration testing, while the second, ETU-2, was for optical testing. This is a report on the optical testing performed on ETU-2 at the NCAR/HAO Vacuum Tunnel Facility during the months of October and November, 2002. This was the same facility used to test the two previous breadboard models. In both configurations, the first two tube sections were complete, with all optical elements aligned. The vibration model ETU-1 had the remaining tube sections attached, with mass models for the remaining optics, for the various mechanisms, and for the focal plane assembly. It was then converted into the optical model ETU-2 by removing tube sections 3 to 5, and mounting the remaining optics on commercial mounts. (The bandpass filter was also installed into tube 2, which had been replaced in ETU-1 by a mass model, so that pre- and post-vibration optical measurements could be made.) Doublet 2 was installed in a Newport LP-2 carrier, and aligned to the other optics in the first two tube sections. The LP-2 adjustment screws were then uralened so that the alignment could be maintained during shipping. Because neither the flight polarizer nor Hollow Core Motor were available, they were simulated by a commercial polarizer and rotational mount, both from Oriel corporation. The Oriel rotational stage was not designed for vacuum use, but it was determined after consultation with the company, and lab testing, that the stage could be used in the moderate vacuum conditions at the NCAR/HAO facility. The shutter and focal plane assembly were simulated with the same camera used for the previous two breadboard tests. The focal plane mask was simulated with a plane of BK7 glass with a mask glued on, using the same procedure as for the Lyot spot on Doublet 1, and mounted in an adjustable LP-2 carrier. Two masks were made, one made to the precise specifications of the optical design, the other slightly bigger to make alignment easier.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colldelram, Carles, E-mail: ccolldelram@cells.es; Nicolas, Josep, E-mail: jnicolas@cells.es; Nikitina, Liudmila, E-mail: lnikitina@cells.es

    In this work we report the design and performance of a novel compact in-vacuum actuator, designed to be compatible with all the motions required for the scissor-type ESRF mirror bender. These mirror benders include several linear actuators, which drive the mirror bending torques, as well as the main alignment motions such as pitch and translation along the normal to the mirror surface. The motions are provided by compact linear actuators, which consist of motor, reduction, spindle and nut, encapsulated on a closed air volume to provide vacuum compatibility. The actuator includes a hydroformed bellows to transmit the force to themore » actuator tip, and an electrical feedthrough for the motor cables. The design boundaries for these actuators are quite tight, as they must be integrated in a narrow volume, must be UHV compatible and must provide high resolution, for a relatively high load. As a result, they have limited mechanical performance, and in some cases poor reliability. To overcome these problems, we designed and implemented a different concept. In the proposed concept, the motor rotation is converted onto a linear motion by means of a cam instead of a spindle and a nut. This allows for much shorter and stiffer transmission system, with similar dimensions. The vacuum compatibility is intrinsic for this solution, since the whole mechanism of the actuator is UHV compatible. All motions are preloaded and guided by vacuum compatible (hybrid metal-ceramics) ball bearings. This allows the system reaching a repeatability and backlash well within the micron. The absence of friction allows for a high reliability and releases the maintenance needs of the system. The transmission is intrinsically irreversible, and the system can hold a load of 250 N within a few nanometers without any holding current on the motors. This allows the system to move reliably also in micro-stepping mode, providing a resolution well below the half-step nominal resolution of 100 nm. Performances have been tested on a prototype. We report the results of the tests obtained in air and in vacuum after bake-out. Two units of the new actuator have been installed at the photoemission beamline of ALBA (CIRCE) and are routinely used to align the 3 µm spot on the field of view of the Photoemission Electron Microscope. The absence of any noticeable backlash, or any friction effect and the reliability of the micro-stepping motion has simplified very much the alignment of the photon beam, reducing the alignment process to few minutes. The excellent performances and relatively high load capacity of this new compact actuator make of it a versatile element to be integrated in other systems requiring reliable in-vacuum positioning.« less

  10. Coverage-Dependent Anchoring of 4,4'-Biphenyl Dicarboxylic Acid to CoO(111) Thin Films.

    PubMed

    Mohr, Susanne; Schmitt, Tobias; Döpper, Tibor; Xiang, Feifei; Schwarz, Matthias; Görling, Andreas; Schneider, M Alexander; Libuda, Jörg

    2017-05-02

    We investigated the adsorption behavior of 4,4'-biphenhyl dicarboxylic acid (BDA) on well-ordered CoO(111) films grown on Ir(100) as a function of coverage and temperature using time-resolved and temperature-programmed infrared reflection absorption spectroscopy (TR-IRAS, TP-IRAS) in combination with density functional theory (DFT) and scanning tunneling microscopy (STM) under ultrahigh vacuum (UHV) conditions. To compare the binding behavior of BDA as a function of the oxide film thickness, three different CoO(111) film thicknesses were explored: films of about 20 bilayers (BLs) (approximately 5 nm), 2 BLs, and 1 BL. The two carboxylic acid groups of BDA offer two potential anchoring points to the oxide surface. At 150 K, intact BDA adsorbs on 20 BL thick oxide films in planar geometry with the phenyl rings aligned parallel to the surface. With decreasing oxide film thickness, we observe an increasing tendency for deprotonation and the formation of flat-lying BDA molecules anchored as dicarboxylates. After saturation of the first monolayer, intact BDA multilayers grow with molecules aligned parallel to the surface. The BDA multilayer desorbs at around 360 K. Completely different growth behavior is observed if BDA is deposited above the multilayer desorption temperature. Initially, doubly deprotonated dicarboxylates are formed by adopting a flat-lying orientation. With increasing exposure, however, the adsorbate layer transforms into upright standing monocarboxylates. A sharp OH stretching band (3584 cm -1 ) and a blue-shifted CO stretching band (1759 cm -1 ) indicate weakly interacting apical carboxylic acid groups at the vacuum interface. The anchored monocarboxylate phase slowly desorbs in a temperature range of up to 470 K. At higher temperature, a flat-lying doubly deprotonated BDA is formed, which desorbs and decomposes in a temperature range of up to 600 K.

  11. Solid Lubrication by Multiwalled Carbon Nanotubes in Air and in Vacuum for Space and Aeronautics Applications

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa; Street, Kenneth W., Jr.; Andraws, Rodney; Jacques, David; VanderWal, Randy L.; Sayir, Ali

    2005-01-01

    To evaluate recently developed aligned multiwalled carbon nanotubes (MWNTs) and dispersed MWNTs for solid lubrication applications, unidirectional sliding friction experiments were conducted with 440 C stainless steel balls and hemispherical alumina-yttria stabilized zirconia pins in sliding contact with the MWNTs deposited on quartz disks in air and in vacuum. The results indicate that MWNTs have superior solid lubrication friction properties and endurance lives in air and vacuum under dry conditions. The coefficient of friction of the dispersed MWNTs is close to 0.05 and 0.009 in air and in vacuum, respectively, showing good dry lubricating ability. The wear life of MWNTs exceeds 1 million passes in both air and vacuum showing good durability. In general, the low coefficient of friction can be attributed to the combination of the transferred, agglomerated patches of MWNTs on the counterpart ball or pin surfaces and the presence of tubular MWNTs at interfaces.

  12. Vapor-barrier Vacuum Isolation System

    NASA Technical Reports Server (NTRS)

    Weinstein, Leonard M. (Inventor); Taminger, Karen M. (Inventor)

    2014-01-01

    A system includes a collimated beam source within a vacuum chamber, a condensable barrier gas, cooling material, a pump, and isolation chambers cooled by the cooling material to condense the barrier gas. Pressure levels of each isolation chamber are substantially greater than in the vacuum chamber. Coaxially-aligned orifices connect a working chamber, the isolation chambers, and the vacuum chamber. The pump evacuates uncondensed barrier gas. The barrier gas blocks entry of atmospheric vapor from the working chamber into the isolation chambers, and undergoes supersonic flow expansion upon entering each isolation chamber. A method includes connecting the isolation chambers to the vacuum chamber, directing vapor to a boundary with the working chamber, and supersonically expanding the vapor as it enters the isolation chambers via the orifices. The vapor condenses in each isolation chamber using the cooling material, and uncondensed vapor is pumped out of the isolation chambers via the pump.

  13. Note: O-ring stack system for electron gun alignment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, In-Yong; Cho, Boklae; Han, Cheolsu

    We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignmentmore » and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.« less

  14. Around Marshall

    NASA Image and Video Library

    1997-10-31

    The Shooting Star Experiment (SSE) is designed to develop and demonstrate the technology required to focus the sun's energy and use the energy for inexpensive space Propulsion Research. Pictured is an engineering model (Pathfinder III) of the Shooting Star Experiment (SSE). This model was used to test and characterize the motion and deformation of the structure caused by thermal effects. In this photograph, alignment targets are being placed on the engineering model so that a theodolite (alignment telescope) could be used to accurately measure the deformation and deflections of the engineering model under extreme conditions, such as the coldness of deep space and the hotness of the sun as well as vacuum. This thermal vacuum test was performed at the X-Ray Calibration Facility because of the size of the test article and the capabilities of the facility to simulate in-orbit conditions

  15. Shooting Star Experiment

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The Shooting Star Experiment (SSE) is designed to develop and demonstrate the technology required to focus the sun's energy and use the energy for inexpensive space Propulsion Research. Pictured is an engineering model (Pathfinder III) of the Shooting Star Experiment (SSE). This model was used to test and characterize the motion and deformation of the structure caused by thermal effects. In this photograph, alignment targets are being placed on the engineering model so that a theodolite (alignment telescope) could be used to accurately measure the deformation and deflections of the engineering model under extreme conditions, such as the coldness of deep space and the hotness of the sun as well as vacuum. This thermal vacuum test was performed at the X-Ray Calibration Facility because of the size of the test article and the capabilities of the facility to simulate in-orbit conditions

  16. Optical Alignment of the Chromospheric Lyman-Alpha SpectroPolarimeter using Sophisticated Methods to Minimize Activities under Vacuum

    NASA Technical Reports Server (NTRS)

    Giono, G.; Katsukawa, Y.; Ishikawa, R.; Narukage, N.; Kano, R.; Kubo, M.; Ishikawa, S.; Bando, T.; Hara, H.; Suematsu, Y.; hide

    2016-01-01

    The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument developed at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. The in- strument main scientific goal is to achieve polarization measurement of the Lyman-alpha line at 121.56 nm emitted from the solar upper-chromosphere and transition region with an unprecedented 0.1% accuracy. For this purpose, the optics are composed of a Cassegrain telescope coated with a "cold mirror" coating optimized for UV reflection and a dual-channel spectrograph allowing for simultaneous observation of the two orthogonal states of polarization. Although the polarization sensitivity is the most important aspect of the instrument, the spatial and spectral resolutions of the instrument are also crucial to observe the chromospheric features and resolve the Ly- pro les. A precise alignment of the optics is required to ensure the resolutions, but experiments under vacuum conditions are needed since Ly-alpha is absorbed by air, making the alignment experiments difficult. To bypass this issue, we developed methods to align the telescope and the spectrograph separately in visible light. We will explain these methods and present the results for the optical alignment of the CLASP telescope and spectrograph. We will then discuss the combined performances of both parts to derive the expected resolutions of the instrument, and compare them with the flight observations performed on September 3rd 2015.

  17. Optomechanical design of the vacuum compatible EXCEDE's mission testbed

    NASA Astrophysics Data System (ADS)

    Bendek, Eduardo A.; Belikov, Ruslan; Lozi, Julien; Schneider, Glenn; Thomas, Sandrine; Pluzhnik, Eugene; Lynch, Dana

    2014-08-01

    In this paper we describe the opto-mechanical design, tolerance error budget an alignment strategies used to build the Starlight Suppression System (SSS) for the Exoplanetary Circumstellar Environments and Disk Explorer (EXCEDE) NASA's mission. EXCEDE is a highly efficient 0.7m space telescope concept designed to directly image and spatially resolve circumstellar disks with as little as 10 zodis of circumstellar dust, as well as large planets. The main focus of this work was the design of a vacuum compatible opto-mechanical system that allows remote alignment and operation of the main components of the EXCEDE. SSS, which are: a Phase Induced Amplitude Apodization (PIAA) coronagraph to provide high throughput and high contrast at an inner working angle (IWA) equal to the diffraction limit (IWA = 1.2 l/D), a wavefront (WF) control system based on a Micro-Electro-Mechanical-System deformable mirror (MEMS DM), and low order wavefront sensor (LOWFS) for fine pointing and centering. We describe in strategy and tolerance error budget for this system, which is especially relevant to achieve the theoretical performance that PIAA coronagraph can offer. We also discuss the vacuum cabling design for the actuators, cameras and the Deformable Mirror. This design has been implemented at the vacuum chamber facility at Lockheed Martin (LM), which is based on successful technology development at the Ames Coronagraph Experiment (ACE) facility.

  18. Molecular alignment and orientation with a hybrid Raman scattering technique

    NASA Astrophysics Data System (ADS)

    Bustard, Philip J.; Lausten, R.; Sussman, Benjamin J.

    2012-11-01

    We demonstrate a scheme for the preparation of molecular alignment and angular momentum orientation using a hybrid combination of two limits of Raman scattering. First a weak, impulsive pump pulse initializes the system via the nonresonant dynamic Stark effect. Then, having overcome the influence of the vacuum fluctuations, an amplification pulse selectively enhances the initial coherences by transient stimulated Raman scattering, generating alignment and angular momentum orientation of molecular hydrogen. The amplitude and phase of the resulting coherent dynamics are experimentally probed, indicating an amplification factor of 4.5. An analytic theory is developed to model the dynamics.

  19. Investigation of compaction and permeability during the out-of-autoclave and vacuum-bag-only manufacturing of a laminate composite with aligned carbon nanofibers

    NASA Astrophysics Data System (ADS)

    Mann, Erin

    Both industry and commercial entities are in the process of using more lightweight composites. Fillers, such as fibers, nanofibers and other nanoconstituents in polymer matrix composites have been proven to enhance the properties of composites and are still being studied in order to optimize the benefits. Further optimization can be studied during the manufacturing process. The air permeability during the out-of-autoclave-vacuum-bag-only (OOA-VBO) cure method is an important property to understand during the optimization of manufacturing processes. Changes in the manufacturing process can improve or decrease composite quality depending on the ability of the composite to evacuate gases such as air and moisture during curing. Therefore, in this study, the axial permeability of a prepreg stack was experimentally studied. Three types of samples were studied: control (no carbon nanofiber (CNF) modification), unaligned CNF modified and aligned CNF modified samples.

  20. Optical alignment of the JWST ISIM to the OTE simulator (OSIM): current concept and design studies

    NASA Astrophysics Data System (ADS)

    Frey, Bradley J.; Davila, Pamela S.; Hagopian, John G.; Marsh, James M.; Ohl, Raymond G.; Wilson, Mark E.; Young, Philip J.

    2007-09-01

    The James Webb Space Telescope's (JWST) Integrated Science Instrument Module (ISIM) contains the observatory's four science instruments and their support subsystems. During alignment and test of the integrated ISIM at NASA's Goddard Space Flight Center (GSFC), the Optical telescope element SIMulator (OSIM) will be used to optically stimulate the science instruments to verify their operation and performance. In this paper we present the design of two cryogenic alignment fixtures that will be used to align the OSIM to the ISIM during testing at GSFC. These fixtures, the Master Alignment Target Fixture (MATF) and the ISIM Alignment Target Fixture (IATF), will provide continuous, six degree of freedom feedback to OSIM during initial ambient alignment as well as during cryogenic vacuum testing. These fixtures will allow us to position the OSIM and detect OSIM-ISIM absolute alignment to better than 180 microns in translation and 540 micro-radians in rotation. We will provide a brief overview of the OSIM system and we will also discuss the relevance of these fixtures in the context of the overall ISIM alignment and test plan.

  1. Compact cryogenic system with mechanical cryocoolers for antihydrogen synthesis.

    PubMed

    Shibata, M; Mohri, A; Kanai, Y; Enomoto, Y; Yamazaki, Y

    2008-01-01

    We have developed a compact cryogenic system which cools a vacuum chamber housing multi-ring trap electrodes (MRTs) of an antihydrogen synthesis trap using mechanical cryocoolers to achieve background pressure less than 10(-12) Torr. The vacuum chamber and the cryocoolers are thermally connected by copper strips of 99.9999% in purity. All components are installed within a diametric gap between the MRT of phi108 mm and a magnet bore of phi160 mm. An adjusting mechanism is prepared to align the MRT axis to the magnet axis. The vacuum chamber was successfully cooled down to 4.0 K after 14 h of cooling with heat load of 0.8 W.

  2. Carbon nanotubes based vacuum gauge

    NASA Astrophysics Data System (ADS)

    Rudyk, N. N.; Il'in, O. I.; Il'ina, M. V.; Fedotov, A. A.; Klimin, V. S.; Ageev, O. A.

    2017-11-01

    We have created an ionization type Vacuum gauge with sensor element based on an array of vertically aligned carbon nanotubes. Obtained asymmetrical current-voltage characteristics at different voltage polarity on the electrode with the CNTs. It was found that when applying a negative potential on an electrode with the CNTs, the current in the gap is higher than at a positive potential. In the pressure range of 1 ÷ 103 Torr vacuum gauge sensitivity was 6 mV/Torr (at a current of 4.5·10-5 A) and in the range of 10-5 ÷ 1 Torr was 10 mV/Torr (at a current of 1.3·10-5 A). It is shown that the energy efficiency of vacuum gauge can be increased in the case where electrode with CNT operates as an emitter of electrons.

  3. Exploratory studies on a passively triggered vacuum spark

    NASA Astrophysics Data System (ADS)

    Rout, R. K.; Auluck, S. K. H.; Nagpal, J. S.; Kulkarni, L. V.

    1999-12-01

    The results of an experimental investigation on a passively triggered vacuum spark device are presented. The diagnostics include the current, x-ray and optical emission measurements. The sharp dips in the current derivative signal indicate the occurrence of pinching at an early stage of the discharge (at current icons/Journals/Common/approx" ALT="approx" ALIGN="TOP"/>5 kA). A well-confined plasma with a central hot region was recorded using a streak camera. The pinched plasma was observed to undergo kink-type oscillations with a time period of 10-15 ns. Repeated plasma fronts were seen to move from the anode to the cathode with an average velocity of icons/Journals/Common/approx" ALT="approx" ALIGN="TOP"/>5 × 106 cm s-1. Soft x-ray emission having a radiation intensity of a few hundred mR per discharge was observed. The x-ray signals obtained using photodiodes showed multiple bursts. A soft x-ray pinhole camera recorded micro-pinches of icons/Journals/Common/approx" ALT="approx" ALIGN="TOP"/>100 µm. The x-ray emitting regions were confined to the inter-electrode gap. The x-ray emission characteristics were influenced by the electrolytic resistance, which was connected across the spark gap to initiate discharge.

  4. JWST Integrated Science Instrument Module Alignment Optimization Tool

    NASA Technical Reports Server (NTRS)

    Bos, Brent

    2013-01-01

    During cryogenic vacuum testing of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM), the global alignment of the ISIM with respect to the designed interface of the JWST optical telescope element (OTE) will be measured through a series of optical characterization tests. These tests will determine the locations and orientations of the JWST science instrument projected focal surfaces and entrance pupils with respect to their corresponding OTE optical interfaces. If any optical performance non-compliances are identified, the ISIM will be adjusted to improve its performance. In order to understand how to manipulate the ISIM's degrees of freedom properly and to prepare for the ISIM flight model testing, a series of optical-mechanical analyses have been completed to develop and identify the best approaches for bringing a non-compliant ISIM element into compliance. In order for JWST to meet its observatory-level optical requirements and ambitious science goals, the ISIM element has to meet approximately 150 separate optical requirements. Successfully achieving many of those optical requirements depends on the proper alignment of the ISIM element with respect to the OTE. To verify that the ISIM element will meet its optical requirements, a series of cryogenic vacuum tests will be conducted with an OTE Simulator (OSIM). An optical Ray Trace and Geometry Model tool was developed to help solve the multi-dimensional alignment problem. The tool allows the user to determine how best to adjust the alignment of the JWST ISIM with respect to the ideal telescope interfaces so that the approximately 150 ISIM optical performance requirements can be satisfied. This capability has not existed previously.

  5. Focus adjustment method for CBERS 3 and 4 satellites Mux camera to be performed in air condition and its experimental verification for best performance in orbital vacuum condition

    NASA Astrophysics Data System (ADS)

    Scaduto, Lucimara C. N.; Malavolta, Alexandre T.; Modugno, Rodrigo G.; Vales, Luiz F.; Carvalho, Erica G.; Evangelista, Sérgio; Stefani, Mario A.; de Castro Neto, Jarbas C.

    2017-11-01

    The first Brazilian remote sensing multispectral camera (MUX) is currently under development at Opto Eletronica S.A. It consists of a four-spectral-band sensor covering a 450nm to 890nm wavelength range. This camera will provide images within a 20m ground resolution at nadir. The MUX camera is part of the payload of the upcoming Sino-Brazilian satellites CBERS 3&4 (China-Brazil Earth Resource Satellite). The preliminary alignment between the optical system and the CCD sensor, which is located at the focal plane assembly, was obtained in air condition, clean room environment. A collimator was used for the performance evaluation of the camera. The preliminary performance evaluation of the optical channel was registered by compensating the collimator focus position due to changes in the test environment, as an air-to-vacuum environment transition leads to a defocus process in this camera. Therefore, it is necessary to confirm that the alignment of the camera must always be attained ensuring that its best performance is reached for an orbital vacuum condition. For this reason and as a further step on the development process, the MUX camera Qualification Model was tested and evaluated inside a thermo-vacuum chamber and submitted to an as-orbit vacuum environment. In this study, the influence of temperature fields was neglected. This paper reports on the performance evaluation and discusses the results for this camera when operating within those mentioned test conditions. The overall optical tests and results show that the "in air" adjustment method was suitable to be performed, as a critical activity, to guarantee the equipment according to its design requirements.

  6. Propagation and stability characteristics of a 500-m-long laser-based fiducial line for high-precision alignment of long-distance linear accelerators.

    PubMed

    Suwada, Tsuyoshi; Satoh, Masanori; Telada, Souichi; Minoshima, Kaoru

    2013-09-01

    A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailed description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.

  7. Propagation and stability characteristics of a 500-m-long laser-based fiducial line for high-precision alignment of long-distance linear accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suwada, Tsuyoshi; Satoh, Masanori; Telada, Souichi

    2013-09-15

    A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailedmore » description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libkind, M.; Bertolini, L.; Duffy, P.

    As part of the research and development effort for a 4th generation light source, we have designed a 4-meter long Free-Electron Laser (FEL) undulator. The undulator will be installed at the Accelerator Test Facility (ATF) at Brookhaven National Laboratory to conduct a Self-Amplified Spontaneous Emission (SASE) demonstration. The demonstration is called VISA, which stands for "Visible to Infrared SASE Amplifier." The undulator consists of 440 permanent dipole magnets per meter which are supported and aligned on a precision strongback. Focusing and defocusing permanent quadrupole magnets are also supported by the strongback. Each of the 4 one-meter sections of undulator aremore » kinematically supported and housed within the vacuum vessel. The undulator and the vacuum vessel are supported independently to eliminate undulator misalignment during vacuum pump-down of the vessel. We describe the design requirements and features of the undulator, vacuum vessel and support system.« less

  9. Generating Atomistic Slab Surfaces with Adsorbates

    DTIC Science & Technology

    2017-12-01

    OTHER DEALINGS IN THE SOFTWARE. from six.moves import range import os import sys import math import copy import numpy as np from...import StructureMatcher from math import acos from mpinterfaces.utils import align_axis, add_vacuum from pymatgen.analysis.structure_matcher import

  10. Mask aligner for ultrahigh vacuum with capacitive distance control

    NASA Astrophysics Data System (ADS)

    Bhaskar, Priyamvada; Mathioudakis, Simon; Olschewski, Tim; Muckel, Florian; Bindel, Jan Raphael; Pratzer, Marco; Liebmann, Marcus; Morgenstern, Markus

    2018-04-01

    We present a mask aligner driven by three piezomotors which guides and aligns a SiN shadow mask under capacitive control towards a sample surface. The three capacitors for read out are located at the backside of the thin mask such that the mask can be placed at a μm distance from the sample surface, while keeping it parallel to the surface, without touching the sample by the mask a priori. Samples and masks can be exchanged in-situ and the mask can additionally be displaced parallel to the surface. We demonstrate an edge sharpness of the deposited structures below 100 nm, which is likely limited by the diffusion of the deposited Au on Si(111).

  11. Energy level alignment and band bending at organic interfaces

    NASA Astrophysics Data System (ADS)

    Seki, Kazuhiko; Oji, Hiroshi; Ito, Eisuke; Hayashi, Naoki; Ouchi, Yukio; Ishii, Hisao

    1999-12-01

    Recent progress in the study of the energy level alignment and band bending at organic interfaces is reviewed, taking the examples mainly from the results of the group of the authors using ultraviolet photoelectron spectroscopy (UPS), metastable atom electron spectroscopy (MAES), and Kelvin probe method (KPM). As for the energy level alignment right at the interface, the formation of an electric dipole layer is observed for most of the organic/metal interfaces, even when no significant chemical interaction is observed. The origin of this dipole layer is examined by accumulating the data of various combinations of organics and metals, and the results indicate combined contribution from (1) charge transfer (CT) between the organic molecule and the metal, and (2) pushback of the electrons spilled out from metal surface, for the case of nonpolar organic molecule physisorbed on metals. Other factors such as chemical interaction and the orientation of polar molecules are also pointed out. As for the band bending, the careful examination of the existence/absence of band bending of purified TPD* molecule deposited on various metals in ultrahigh vacuum (UHV) revealed negligible band bending up to 100 nm thickness, and also the failure of the establishment of Fermi level alignment between organic layer and the metals. The implications of these findings are discussed, in relation to the future prospects of the studies in this field. (*:N,N'- diphenyl-N,N'-(3-methylphenyl)-1,1'-biphenyl-4,4'-diamine).

  12. Laser beam centering and pointing system

    DOEpatents

    Rushford, Michael Charles

    2015-01-13

    An optical instrument aligns an optical beam without the need for physical intervention of the instrument within the apparatus or platforms from which the trajectory of the beam to be ascertained. The alignment apparatus and method enable the desired function to be realized without the placement of physical apertures or sensors directly in the path of the beam through the system whose spatial position and slope is to be sought. An image plane provides the observer with a pair of well-defined images that are indicative of the beam centering and pointing alignment parameters. The optical alignment can be realized without the need for referencing to an external or fixed set of coordinates or fiducials. The instrument can therefore service situations where adverse environments would otherwise prohibit the use of such instruments, including regions of high radiation, high temperature, vacuum and/or cryogenic atmospheres.

  13. Fabrication of high gradient insulators by stack compression

    DOEpatents

    Harris, John Richardson; Sanders, Dave; Hawkins, Steven Anthony; Norona, Marcelo

    2014-04-29

    Individual layers of a high gradient insulator (HGI) are first pre-cut to their final dimensions. The pre-cut layers are then stacked to form an assembly that is subsequently pressed into an HGI unit with the desired dimension. The individual layers are stacked, and alignment is maintained, using a sacrificial alignment tube that is removed after the stack is hot pressed. The HGI's are used as high voltage vacuum insulators in energy storage and transmission structures or devices, e.g. in particle accelerators and pulsed power systems.

  14. SU-E-J-94: Positioning Errors Resulting From Using Bony Anatomy Alignment for Treating SBRT Lung Tumor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frame, C; Ding, G

    Purpose: To quantify patient setups errors based on bony anatomy registration rather than 3D tumor alignment for SBRT lung treatments. Method: A retrospective study was performed for patients treated with lung SBRT and imaged with kV cone beam computed tomography (kV-CBCT) image-guidance. Daily CBCT images were registered to treatment planning CTs based on bony anatomy alignment and then inter-fraction tumor movement was evaluated by comparing shift in the tumor center in the medial-lateral, anterior-posterior, and superior-inferior directions. The PTV V100% was evaluated for each patient based on the average daily tumor displacement to assess the impact of the positioning errormore » on the target coverage when the registrations were based on bony anatomy. Of the 35 patients studied, 15 were free-breathing treatments, 10 used abdominal compression with a stereotactic body frame, and the remaining 10 were performed with BodyFIX vacuum bags. Results: For free-breathing treatments, the range of tumor displacement error is between 1–6 mm in the medial-lateral, 1–13 mm in the anterior-posterior, and 1–7 mm in the superior-inferior directions. These positioning errors lead to 6–22% underdose coverage for PTV - V100% . Patients treated with abdominal compression immobilization showed positional errors of 0–4mm mediallaterally, 0–3mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% underdose ranging between 6–17%. For patients immobilized with the vacuum bags, the positional errors were found to be 0–1 mm medial-laterally, 0–1mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% under dose ranging between 5–6% only. Conclusion: It is necessary to align the tumor target by using 3D image guidance to ensure adequate tumor coverage before performing SBRT lung treatments. The BodyFIX vacuum bag immobilization method has the least positioning errors among the three methods studied when bony anatomy is used for registration.« less

  15. A method to align a bent crystal for channeling experiments by using quasichanneling oscillations

    NASA Astrophysics Data System (ADS)

    Sytov, A. I.; Guidi, V.; Tikhomirov, V. V.; Bandiera, L.; Bagli, E.; Germogli, G.; Mazzolari, A.; Romagnoni, M.

    2018-04-01

    A method to calculate both the bent crystal angle of alignment and radius of curvature by using only one distribution of deflection angles has been developed. The method is based on measuring of the angular position of recently predicted and observed quasichanneling oscillations in the deflection angle distribution and consequent fitting of both the radius and angular alignment by analytic formulae. In this paper this method is applied on the example of simulated angular distributions over a wide range of values of both radius and alignment for electrons. It is carried out through the example of (111) nonequidistant planes though this technique is general and could be applied to any kind of planes. In addition, the method application constraints are also discussed. It is shown by simulations that this method, being in fact a sort of beam diagnostics, allows one in a certain case to increase the crystal alignment accuracy as well as to control precisely the radius of curvature inside an accelerator tube without vacuum breaking. In addition, it speeds up the procedure of crystal alignment in channeling experiments, reducing beamtime consuming.

  16. Transmission geometry laserspray ionization vacuum using an atmospheric pressure inlet.

    PubMed

    Lutomski, Corinne A; El-Baba, Tarick J; Inutan, Ellen D; Manly, Cory D; Wager-Miller, James; Mackie, Ken; Trimpin, Sarah

    2014-07-01

    This represents the first report of laserspray ionization vacuum (LSIV) with operation directly from atmospheric pressure for use in mass spectrometry. Two different types of electrospray ionization source inlets were converted to LSIV sources by equipping the entrance of the atmospheric pressure inlet aperture with a customized cone that is sealed with a removable glass plate holding the matrix/analyte sample. A laser aligned in transmission geometry (at 180° relative to the inlet) ablates the matrix/analyte sample deposited on the vacuum side of the glass slide. Laser ablation from vacuum requires lower inlet temperature relative to laser ablation at atmospheric pressure. However, higher inlet temperature is required for high-mass analytes, for example, α-chymotrypsinogen (25.6 kDa). Labile compounds such as gangliosides and cardiolipins are detected in the negative ion mode directly from mouse brain tissue as intact doubly deprotonated ions. Multiple charging enhances the ion mobility spectrometry separation of ions derived from complex tissue samples.

  17. Transmission Geometry Laserspray Ionization Vacuum Using an Atmospheric Pressure Inlet

    PubMed Central

    2015-01-01

    This represents the first report of laserspray ionization vacuum (LSIV) with operation directly from atmospheric pressure for use in mass spectrometry. Two different types of electrospray ionization source inlets were converted to LSIV sources by equipping the entrance of the atmospheric pressure inlet aperture with a customized cone that is sealed with a removable glass plate holding the matrix/analyte sample. A laser aligned in transmission geometry (at 180° relative to the inlet) ablates the matrix/analyte sample deposited on the vacuum side of the glass slide. Laser ablation from vacuum requires lower inlet temperature relative to laser ablation at atmospheric pressure. However, higher inlet temperature is required for high-mass analytes, for example, α-chymotrypsinogen (25.6 kDa). Labile compounds such as gangliosides and cardiolipins are detected in the negative ion mode directly from mouse brain tissue as intact doubly deprotonated ions. Multiple charging enhances the ion mobility spectrometry separation of ions derived from complex tissue samples. PMID:24896880

  18. CASTING FURNACES

    DOEpatents

    Ruppel, R.H.; Winters, C.E.

    1961-01-01

    A device is described for casting uranium which comprises a crucible, a rotatable table holding a plurality of molds, and a shell around both the crucible and the table. The bottom of the crucible has an eccentrically arranged pouring hole aligned with one of the molds at a time. The shell can be connected with a vacuum.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    TREMAINE,A.; MUROKH,A.; WANG,X.J.

    The VISA experiment is designed to reach and study saturation in a high gain 800nm SASE FEL at the Brookhaven Accelerator Test Facility (ATF). To do this, the undulator must be aligned at first to within 20 {micro}m with use of a laser interferometric system. Once aligned, any small movements from the aligned position will greatly detriment the SASE FEL performance thus making continuous monitoring of the undulator position necessary. This is quite a complicated task since the 4m undulator is made up of four 1m sections enclosed in a vacuum chamber. We have developed an in situ optical systemmore » to monitor the undulator position with an accuracy better than 10 {micro}m. In addition, we have demonstrated the accuracy of this system by bringing the grossly misaligned VISA undulator ({approximately} 500 {micro}m in some locations) into alignment and attaining very high gain of the SASE FEL.« less

  20. Electron beam gun with kinematic coupling for high power RF vacuum devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borchard, Philipp

    An electron beam gun for a high power RF vacuum device has components joined by a fixed kinematic coupling to provide both precise alignment and high voltage electrical insulation of the components. The kinematic coupling has high strength ceramic elements directly bonded to one or more non-ductile rigid metal components using a high temperature active metal brazing alloy. The ceramic elements have a convex surface that mates with concave grooves in another one of the components. The kinematic coupling, for example, may join a cathode assembly and/or a beam shaping focus electrode to a gun stem, which is preferably composedmore » of ceramic. The electron beam gun may be part of a high power RF vacuum device such as, for example, a gyrotron, klystron, or magnetron.« less

  1. Interfacial chemical reactions between MoS2 lubricants and bearing materials

    NASA Technical Reports Server (NTRS)

    Zabinski, J. S.; Tatarchuk, B. J.

    1989-01-01

    XPS and conversion-electron Moessbauer spectroscopy (CEMS) were used to examine iron that was deposited on the basal plane of MoS2 single crystals and subjected to vacuum annealing, oxidizing, and reducing environments. Iron either intercalated into the MoS2 structure or formed oriented iron sulfides, depending on the level of excess S in the MoS2 structure. CEMS data demonstrated that iron sulfide crystal structures preferentially aligned with respect to the MoS2 basal plane, and that alignment (and potentially adhesion) could be varied by appropriate high-temperature annealing procedures.

  2. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2001-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  3. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2000-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  4. Vacuum fusion bonded glass plates having microstructures thereon

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2001-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruland, Robert

    The Visible-Infrared SASE Amplifier (VISA) undulator consists of four 99cm long segments. Each undulator segment is set up on a pulsed-wire bench, to characterize the magnetic properties and to locate the magnetic axis of the FODO array. Subsequently, the location of the magnetic axis, as defined by the wire, is referenced to tooling balls on each magnet segment by means of a straightness interferometer. After installation in the vacuum chamber, the four magnet segments are aligned with respect to themselves and globally to the beam line reference laser. A specially designed alignment fixture is used to mount one straightness interferometermore » each in the horizontal and vertical plane of the beam. The goal of these procedures is to keep the combined rms trajectory error, due to magnetic and alignment errors, to 50{micro}m.« less

  6. The Los Alamos National Laboratory precision double crystal spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan, D.V.; Stevens, C.J.; Liefield, R.J.

    1994-03-01

    This report discusses the following topics on the LANL precision double crystal X-ray spectrometer: Motivation for construction of the instrument; a brief history of the instrument; mechanical systems; motion control systems; computer control system; vacuum system; alignment program; scan programs; observations of the copper K{alpha} lines; and characteristics and specifications.

  7. Photoinduced charge transfer from vacuum-deposited molecules to single-layer transition metal dichalcogenides

    NASA Astrophysics Data System (ADS)

    Osada, Kazuki; Tanaka, Masatoshi; Ohno, Shinya; Suzuki, Takanori

    2016-06-01

    Variations of photoluminescence (PL) and Raman spectra of single-layer MoS2, MoSe2, WS2, and WSe2 due to the vacuum deposition of C60 or copper phthalocyanine (CuPc) molecules have been investigated. PL spectra are decomposed into two competitive components, an exciton and a charged exciton (trion), depending on carrier density. The variation of PL spectra is interpreted in terms of charge transfer across the interfaces between transition metal dichalcogenides (TMDs) and dopant molecules. We find that deposited C60 molecules inject photoexcited electrons into MoS2, MoSe2, and WS2 or holes into WSe2. CuPc molecules also inject electrons into MoS2, MoSe2, and WS2, while holes are depleted from WSe2 to CuPc. We then propose a band alignment between TMDs and dopant molecules. Peak shifts of Raman spectra and doped carrier density estimated using a three-level model also support the band alignment. We thus demonstrate photoinduced charge transfer from dopant molecules to single-layer TMDs.

  8. Device for collecting and analyzing matrix-isolated samples

    DOEpatents

    Reedy, Gerald T.

    1979-01-01

    A gas-sample collection device is disclosed for matrix isolation of individual gas bands from a gas chromatographic separation and for presenting these distinct samples for spectrometric examination. The device includes a vacuum chamber containing a rotatably supported, specular carrousel having a number of external, reflecting surfaces around its axis of rotation for holding samples. A gas inlet is provided for depositing sample and matrix material on the individual reflecting surfaces maintained at a sufficiently low temperature to cause solidification. Two optical windows or lenses are installed in the vacuum chamber walls for transmitting a beam of electromagnetic radiation, for instance infrared light, through a selected sample. Positioned within the chamber are two concave mirrors, the first aligned to receive the light beam from one of the lenses and focus it to the sample on one of the reflecting surfaces of the carrousel. The second mirror is aligned to receive reflected light from that carrousel surface and to focus it outwardly through the second lens. The light beam transmitted from the sample is received by a spectrometer for determining absorption spectra.

  9. James Webb Space Telescope: Frequently Asked Questions for Scientists and Engineers

    NASA Technical Reports Server (NTRS)

    Gardner, Jonathan P.

    2008-01-01

    JWST will be tested incrementally during its construction, starting with individual mirrors and instruments (including cameras and spectrometers) and building up to the full observatory. JWST's mirrors and the telescope structure are first each tested individually, including optical testing of the mirrors and alignment testing of the structure inside a cold thermal-vacuum chamber. The mirrors are then installed on the telescope structure in a clean room at Goddard Space Flight Center (GSFC). In parallel to the telescope assembly and alignment, the instruments are being built and tested, again first individually, and then as part of an integrated instrument assembly. The integrated instrument assembly will be tested in a thermal-vacuum chamber at GSFC using an optical simulator of the telescope. This testing makes sure the instruments are properly aligned relative to each other and also provides an independent check of the individual tests. After both the telescope and the integrated instrument module are successfully assembled, the integrated instrument module will be installed onto the telescope, and the combined system will be sent to Johnson Space Flight Center (JSC) where it will be optically tested in one of the JSC chambers. The process includes testing the 18 primary mirror segments acting as a single primary mirror, and testing the end-to-end system. The final system test will assure that the combined telescope and instruments are focused and aligned properly, and that the alignment, once in space, will be within the range of the actively controlled optics. In general, the individual optical tests of instruments and mirrors are the most accurate. The final system tests provide a cost-effective check that no major problem has occurred during assembly. In addition, independent optical checks of earlier tests will be made as the full system is assembled, providing confidence that there are no major problems.

  10. Method for vacuum pressing electrochemical cell components

    NASA Technical Reports Server (NTRS)

    Andrews, Craig C. (Inventor); Murphy, Oliver J. (Inventor)

    2004-01-01

    Assembling electrochemical cell components using a bonding agent comprising aligning components of the electrochemical cell, applying a bonding agent between the components to bond the components together, placing the components within a container that is essentially a pliable bag, and drawing a vacuum within the bag, wherein the bag conforms to the shape of the components from the pressure outside the bag, thereby holding the components securely in place. The vacuum is passively maintained until the adhesive has cured and the components are securely bonded. The bonding agent used to bond the components of the electrochemical cell may be distributed to the bonding surface from distribution channels in the components. To prevent contamination with bonding agent, some areas may be treated to produce regions of preferred adhesive distribution and protected regions. Treatments may include polishing, etching, coating and providing protective grooves between the bonding surfaces and the protected regions.

  11. Precision optical slit for high heat load or ultra high vacuum

    DOEpatents

    Andresen, N.C.; DiGennaro, R.S.; Swain, T.L.

    1995-01-24

    This invention relates generally to slits used in optics that must be precisely aligned and adjusted. The optical slits of the present invention are useful in x-ray optics, x-ray beam lines, optical systems in which the entrance slit is critical for high wavelength resolution. The invention is particularly useful in ultra high vacuum systems where lubricants are difficult to use and designs which avoid the movement of metal parts against one another are important, such as monochromators for high wavelength resolution with ultra high vacuum systems. The invention further relates to optical systems in which temperature characteristics of the slit materials is important. The present invention yet additionally relates to precision slits wherein the opposing edges of the slit must be precisely moved relative to a center line between the edges with each edge retaining its parallel orientation with respect to the other edge and/or the center line. 21 figures.

  12. Precision optical slit for high heat load or ultra high vacuum

    DOEpatents

    Andresen, Nord C.; DiGennaro, Richard S.; Swain, Thomas L.

    1995-01-01

    This invention relates generally to slits used in optics that must be precisely aligned and adjusted. The optical slits of the present invention are useful in x-ray optics, x-ray beam lines, optical systems in which the entrance slit is critical for high wavelength resolution. The invention is particularly useful in ultra high vacuum systems where lubricants are difficult to use and designs which avoid the movement of metal parts against one another are important, such as monochrometers for high wavelength resolution with ultra high vacuum systems. The invention further relates to optical systems in which temperature characteristics of the slit materials is important. The present invention yet additionally relates to precision slits wherein the opposing edges of the slit must be precisely moved relative to a center line between the edges with each edge retaining its parallel orientation with respect to the other edge and/or the center line.

  13. Alignment Test Results of the JWST Pathfinder Telescope Mirrors in the Cryogenic Environment

    NASA Technical Reports Server (NTRS)

    Whitman, Tony L.; Wells, Conrad; Hadaway, James; Knight, J. Scott; Lunt, Sharon

    2016-01-01

    After integration of the Optical Telescope Element (OTE) to the Integrated Science Instrument Module (ISIM) to become the OTIS, the James Webb Space Telescope OTIS is tested at NASAs Johnson Space Center (JSC) in the cryogenic vacuum Chamber A for alignment and optical performance. The alignment of the mirrors comprises a sequence of steps as follows: The mirrors are coarsely aligned using photogrammetry cameras with reflective targets attached to the sides of the mirrors. Then a multi-wavelength interferometer is aligned to the 18-segment primary mirror using cameras at the center of curvature to align reflected light from the segments and using fiducials at the edge of the primary mirror. Once the interferometer is aligned, the 18 primary mirror segments are then adjusted to optimize wavefront error of the aggregate mirror. This process phases the piston and tilt positions of all the mirror segments. An optical fiber placed at the Cassegrain focus of the telescope then emits light towards the secondary mirror to create a collimated beam emitting from the primary mirror. Portions of the collimated beam are retro-reflected from flat mirrors at the top of the chamber to pass through the telescope to the SI detector. The image on the detector is used for fine alignment of the secondary mirror and a check of the primary mirror alignment using many of the same analysis techniques used in the on-orbit alignment. The entire process was practiced and evaluated in 2015 at cryogenic temperature with the Pathfinder telescope.

  14. Safely splicing glass optical fibers

    NASA Technical Reports Server (NTRS)

    Korbelak, K.

    1980-01-01

    Field-repair technique fuses glass fibers in flammable environment. Apparatus consists of v-groove vacuum chucks on manipulators, high-voltage dc power supply and tungsten electrodes, microscope to observe joint alignment and fusion, means of test transmission through joint. Apparatus is enclosed in gas tight bos filled with inert gas during fusion. About 2 feet of fiber end are necessary for splicing.

  15. Simple and sensitive technique for alignment of the pinhole of a spatial filter of a high-energy, high-power laser system.

    PubMed

    Sharma, Avnish Kumar; Patidar, Rajesh Kumar; Daiya, Deepak; Joshi, Anandverdhan; Naik, Prasad Anant; Gupta, Parshotam Dass

    2013-04-20

    In this paper, a new method for alignment of the pinhole of a spatial filter (SF) has been proposed and demonstrated experimentally. The effect of the misalignment of the pinhole on the laser beam profiles has been calculated for circular and elliptical Gaussian laser beams. Theoretical computation has been carried out to illustrate the effect of an intensity mask, placed before the focusing lens of the SF, on the spatial beam profile after the pinhole of the SF. It is shown, both theoretically and experimentally, that a simple intensity mask, consisting of a black dot, can be used to visually align the pinhole with a high accuracy of 5% of the pinhole diameter. The accuracy may be further improved using a computer-based image processing algorithm. Finally, the proposed technique has been demonstrated to align a vacuum SF of a compact 40 J Nd:phosphate glass laser system.

  16. Detecting fiducials affected by trombone delay in ARC and the main laser alignment at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Awwal, Abdul A. S.; Bliss, Erlan S.; Miller Kamm, Victoria; Leach, Richard R.; Roberts, Randy; Rushford, Michael C.; Lowe-Webb, Roger; Wilhelmsen, Karl

    2015-09-01

    Four of the 192 beams of the National Ignition Facility (NIF) are currently being diverted into the Advanced Radiographic Capability (ARC) system to generate a sequence of short (1-50 picoseconds) 1053 nm laser pulses. When focused onto high Z wires in vacuum, these pulses create high energy x-ray pulses capable of penetrating the dense, imploding fusion fuel plasma during ignition scale experiments. The transmitted x-rays imaged with x-ray diagnostics can create movie radiographs that are expected to provide unprecedented insight into the implosion dynamics. The resulting images will serve as a diagnostic for tuning the experimental parameters towards successful fusion reactions. Beam delays introduced into the ARC pulses via independent, free-space optical trombones create the desired x-ray image sequence, or movie. However, these beam delays cause optical distortion of various alignment fiducials viewed by alignment sensors in the NIF and ARC beamlines. This work describes how the position of circular alignment fiducials is estimated in the presence of distortion.

  17. Alignment test results of the JWST Pathfinder Telescope mirrors in the cryogenic environment

    NASA Astrophysics Data System (ADS)

    Whitman, Tony L.; Wells, Conrad; Hadaway, James B.; Knight, J. Scott; Lunt, Sharon

    2016-07-01

    After integration of the Optical Telescope Element (OTE) to the Integrated Science Instrument Module (ISIM) to become the OTIS, the James Webb Space Telescope OTIS is tested at NASA's Johnson Space Center (JSC) in the cryogenic vacuum Chamber A for alignment and optical performance. The alignment of the mirrors comprises a sequence of steps as follows: The mirrors are coarsely aligned using photogrammetry cameras with reflective targets attached to the sides of the mirrors. Then a multi-wavelength interferometer is aligned to the 18-segment primary mirror using cameras at the center of curvature to align reflected light from the segments and using fiducials at the edge of the primary mirror. Once the interferometer is aligned, the 18 primary mirror segments are then adjusted to optimize wavefront error of the aggregate mirror. This process phases the piston and tilt positions of all the mirror segments. An optical fiber placed at the Cassegrain focus of the telescope then emits light towards the secondary mirror to create a collimated beam emitting from the primary mirror. Portions of the collimated beam are retro-reflected from flat mirrors at the top of the chamber to pass through the telescope to the Science Instrument (SI) detector. The image on the detector is used for fine alignment of the secondary mirror and a check of the primary mirror alignment using many of the same analysis techniques used in the on-orbit alignment. The entire process was practiced and evaluated in 2015 at cryogenic temperature with the Pathfinder telescope.

  18. Energy level alignment at the methylammonium lead iodide/copper phthalocyanine interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Shi; Goh, Teck Wee; Sum, Tze Chien, E-mail: Alfred@ntu.edu.sg, E-mail: Tzechien@ntu.edu.sg

    2014-08-01

    The energy level alignment at the CH{sub 3}NH{sub 3}PbI{sub 3}/copper phthalocyanine (CuPc) interface is investigated by X-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS). XPS reveal a 0.3 eV downward band bending in the CuPc film. UPS validate this finding and further reveal negligible interfacial dipole formation – verifying the viability of vacuum level alignment. The highest occupied molecular orbital of CuPc is found to be closer to the Fermi level than the valance band maximum of CH{sub 3}NH{sub 3}PbI{sub 3}, facilitating hole transfer from CH{sub 3}NH{sub 3}PbI{sub 3} to CuPc. However, subsequent hole extraction from CuPc may bemore » impeded by the downward band bending in the CuPc layer.« less

  19. Transition-metal impurities in semiconductors and heterojunction band lineups

    NASA Astrophysics Data System (ADS)

    Langer, Jerzy M.; Delerue, C.; Lannoo, M.; Heinrich, Helmut

    1988-10-01

    The validity of a recent proposal that transition-metal impurity levels in semiconductors may serve as a reference in band alignment in semiconductor heterojunctions is positively verified by using the most recent data on band offsets in the following lattice-matched heterojunctions: Ga1-xAlxAs/GaAs, In1-xGaxAsyP1-y/InP, In1-xGaxP/GaAs, and Cd1-xHgxTe/CdTe. The alignment procedure is justified theoretically by showing that transition-metal energy levels are effectively pinned to the average dangling-bond energy level, which serves as the reference level for the heterojunction band alignment. Experimental and theoretical arguments showing that an increasingly popular notion on transition-metal energy-level pinning to the vacuum level is unjustified and must be abandoned in favor of the internal-reference rule proposed recently [J. M. Langer and H. Heinrich, Phys. Rev. Lett. 55, 1414 (1985)] are presented.

  20. Water Cooled Mirror Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dale, Gregory E.; Holloway, Michael Andrew; Pulliam, Elias Noel

    2015-03-30

    This design is intended to replace the current mirror setup being used for the NorthStar Moly 99 project in order to monitor the target coupon. The existing setup has limited movement for camera alignment and is difficult to align properly. This proposed conceptual design for a water cooled mirror will allow for greater thermal transfer between the mirror and the water block. It will also improve positioning of the mirror by using flexible vacuum hosing and a ball head joint capable of a wide range of motion. Incorporating this design into the target monitoring system will provide more efficient coolingmore » of the mirror which will improve the amount of diffraction caused by the heating of the mirror. The process of aligning the mirror for accurate position will be greatly improved by increasing the range of motion by offering six degrees of freedom.« less

  1. Alignment of a multilayer-coated imaging system using extreme ultraviolet Foucault and Ronchi interferometric testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray-Chaudhuri, A.K.; Ng, W.; Cerrina, F.

    1995-11-01

    Multilayer-coated imaging systems for extreme ultraviolet (EUV) lithography at 13 nm represent a significant challenge for alignment and characterization. The standard practice of utilizing visible light interferometry fundamentally provides an incomplete picture since this technique fails to account for phase effects induced by the multilayer coating. Thus the development of optical techniques at the functional EUV wavelength is required. We present the development of two EUV optical tests based on Foucault and Ronchi techniques. These relatively simple techniques are extremely sensitive due to the factor of 50 reduction in wavelength. Both techniques were utilized to align a Mo--Si multilayer-coated Schwarzschildmore » camera. By varying the illumination wavelength, phase shift effects due to the interplay of multilayer coating and incident angle were uniquely detected. {copyright} {ital 1995} {ital American} {ital Vacuum} {ital Society}« less

  2. [Learning curve of vacuum extraction in residency: a preliminary study].

    PubMed

    Velemir, L; Vendittelli, F; Bonnefoy, C; Accoceberry, M; Savary, D; Gallot, D

    2009-09-01

    The aim of this study was to assess the lurning curve of young residents for vacuum extraction. All vacuum extractions performed in our department by five residents (< or =5th semester) during a study period of nine months were systematically supervised by a senior who fulfilled an assessment questionnaire from which was calculated a score reflecting the quality of the extraction. Fifty-four vacuum extractions were assessed with a mean of 10.8+/-2.9 (range, 10-13) procedures by resident. We compared the group including the six first procedures performed by each resident (group 1, n = 30) with the group including the following procedures (group 2, n = 24). We observed in the group 2 compared to the group 1, a significant improvement of the scores mean (12.3+/-5.4 vs 8.4+/-6.2, p = 0.016) and a significant reduction of the need for manual assistance by the senior (12.5% vs 40%, p = 0.034). We report a method for the learning and assessment of vacuum extraction feasible at "the bed" of the patient. This approach allows to observe a significant progression of the resident for the technique of vacuum extraction on a dozen of procedures.

  3. Controlled growth of aligned carbon nanotube using pulsed glow barrier discharge

    NASA Astrophysics Data System (ADS)

    Nozaki, Tomohiro; Kimura, Yoshihito; Okazaki, Ken

    2002-10-01

    We first achieved a catalytic growth of aligned carbon nanotube (CNT) using atmospheric pressure pulsed glow barrier discharge combined with DC bias (1000 V). Aligned CNT can grow with the directional electric field, and this is a big challenge in barrier discharges since dielectric barrier does not allow DC bias and forces to use AC voltage to maintain stable plasma conditions. To overcome this, we developed a power source generating Gaussian-shape pulses at 20 kpps with 4% duty, and DC bias was applied to the GND electrode where Ni-, Fe-coated substrate existed. With positive pulse, i.e. substrate was the cathode, random growth of CNT was observed at about 10^9 cm-2. Growth rate significantly reduced when applied negative pulse; Negative glow formation near substrate is essential for sufficient supply of radical species to the catalyst. If -DC was biased, aligned CNT with 20 nm was synthesized because negative bias enhanced negative glow formation. Interestingly, 2 to 3 CNTs stuck each other with +DC bias, resulting in 50-70 nm and non-aligned CNT. Atmospheric pressure glow barrier discharges can be highly controlled and be a potential alternative to vacuum plasmas for CVD, micro-scale, nano-scale fabrication.

  4. Thermal/vacuum measurements of the Herschel space telescope by close-range photogrammetry

    NASA Astrophysics Data System (ADS)

    Parian, J. Amiri; Cozzani, A.; Appolloni, M.; Casarosa, G.

    2017-11-01

    In the frame of the development of a videogrammetric system to be used in thermal vacuum chambers at the European Space Research and Technology Centre (ESTEC) and other sites across Europe, the design of a network using micro-cameras was specified by the European Space agency (ESA)-ESTEC. The selected test set-up is the photogrammetric test of the Herschel Satellite Flight Model in the ESTEC Large Space Simulator. The photogrammetric system will be used to verify the Herschel Telescope alignment and Telescope positioning with respect to the Cryostat Vacuum Vessel (CVV) inside the Large Space Simulator during Thermal-Vacuum/Thermal-Balance test phases. We designed a close-range photogrammetric network by heuristic simulation and a videogrammetric system with an overall accuracy of 1:100,000. A semi-automated image acquisition system, which is able to work at low temperatures (-170°C) in order to acquire images according to the designed network has been constructed by ESA-ESTEC. In this paper we will present the videogrammetric system and sub-systems and the results of real measurements with a representative setup similar to the set-up of Herschel spacecraft which was realized in ESTEC Test Centre.

  5. Deformation mechanism of the Cryostat in the CADS Injector II

    NASA Astrophysics Data System (ADS)

    Yuan, Jiandong; Zhang, Bin; Wan, Yuqin; Sun, Guozhen; Bai, Feng; Zhang, Juihui; He, Yuan

    2018-01-01

    Thermal contraction and expansion of the Cryostat will affect its reliability and stability. To optimize and upgrade the Cryostat, we analyzed the heat transfer in a cryo-vacuum environment from the theoretical point first. The simulation of cryo-vacuum deformation based on a finite element method was implemented respectively. The completed measurement based on a Laser Tracker and a Micro Alignment Telescope was conducted to verify its correctness. The monitored deformations were consistent with the simulated ones. After the predictable deformations in vertical direction have been compensated, the superconducting solenoids and Half Wave Resonator cavities approached the ideal "zero" position under liquid helium conditions. These guaranteed the success of 25 MeV@170 uA continuous wave protons of Chinese accelerator driven subcritical system Injector II. By correlating the vacuum and cryo-deformation, we have demonstrated that the complete deformation was the superposition effect of the atmospheric pressure, gravity and thermal stress during both the process of cooling down and warming up. The results will benefit to an optimization for future Cryostat's design.

  6. Detecting Casimir torque with an optically levitated nanorod

    NASA Astrophysics Data System (ADS)

    Xu, Zhujing; Li, Tongcang

    2017-09-01

    The linear momentum and angular momentum of virtual photons of quantum vacuum fluctuations can induce the Casimir force and the Casimir torque, respectively. While the Casimir force has been measured extensively, the Casimir torque has not been observed experimentally though it was predicted over 40 years ago. Here we propose to detect the Casimir torque with an optically levitated nanorod near a birefringent plate in vacuum. The axis of the nanorod tends to align with the polarization direction of the linearly polarized optical tweezer. When its axis is not parallel or perpendicular to the optical axis of the birefringent crystal, it will experience a Casimir torque that shifts its orientation slightly. We calculate the Casimir torque and Casimir force acting on a levitated nanorod near a birefringent crystal. We also investigate the effects of thermal noise and photon recoils on the torque and force detection. We prove that a levitated nanorod in vacuum will be capable of detecting the Casimir torque under realistic conditions, and will be an important tool in precision measurements.

  7. Performance characteristics of nanocrystalline diamond vacuum field emission transistor array

    NASA Astrophysics Data System (ADS)

    Hsu, S. H.; Kang, W. P.; Davidson, J. L.; Huang, J. H.; Kerns, D. V.

    2012-06-01

    Nitrogen-incorporated nanocrystalline diamond (ND) vacuum field emission transistor (VFET) with self-aligned gate is fabricated by mold transfer microfabrication technique in conjunction with chemical vapor deposition (CVD) of nanocrystalline diamond on emitter cavity patterned on silicon-on-insulator (SOI) substrate. The fabricated ND-VFET demonstrates gate-controlled emission current with good signal amplification characteristics. The dc characteristics of the ND-VFET show well-defined cutoff, linear, and saturation regions with low gate turn-on voltage, high anode current, negligible gate intercepted current, and large dc voltage gain. The ac performance of the ND-VFET is measured, and the experimental data are analyzed using a modified small signal circuit model. The experimental results obtained for the ac voltage gain are found to agree with the theoretical model. A higher ac voltage gain is attainable by using a better test setup to eliminate the associated parasitic capacitances. The paper reveals the amplifier characteristics of the ND-VFET for potential applications in vacuum microelectronics.

  8. Performance characteristics of nanocrystalline diamond vacuum field emission transistor array

    NASA Astrophysics Data System (ADS)

    Hsu, S. H.; Kang, W. P.; Davidson, J. L.; Huang, J. H.; Kerns, D. V.

    2012-05-01

    Nitrogen-incorporated nanocrystalline diamond (ND) vacuum field emission transistor (VFET) with self-aligned gate is fabricated by mold transfer microfabrication technique in conjunction with chemical vapor deposition (CVD) of nanocrystalline diamond on emitter cavity patterned on silicon-on-insulator (SOI) substrate. The fabricated ND-VFET demonstrates gate-controlled emission current with good signal amplification characteristics. The dc characteristics of the ND-VFET show well-defined cutoff, linear, and saturation regions with low gate turn-on voltage, high anode current, negligible gate intercepted current, and large dc voltage gain. The ac performance of the ND-VFET is measured, and the experimental data are analyzed using a modified small signal circuit model. The experimental results obtained for the ac voltage gain are found to agree with the theoretical model. A higher ac voltage gain is attainable by using a better test setup to eliminate the associated parasitic capacitances. The paper reveals the amplifier characteristics of the ND-VFET for potential applications in vacuum microelectronics.

  9. Photoinduced electron transfer at the tetrapyrrole-TiO2 interface: Effect of the energy alignment

    NASA Astrophysics Data System (ADS)

    Nieto-Pescador, Jesus S.

    Photoinduced electron transfer is a ubiquitous process behind several physical, chemical, and biological processes. Its potential applications, ranging from solar cell technologies to photodynamic cancer therapy, require a thorough understanding of the basics of the reaction. This dissertation addresses open questions for a particular case of electron transfer processes: Heterogeneous Electron Transfer (HET). In this process, an electron is transferred between a localized donor and a multitude of delocalized acceptor states. HET between photoexcited tetrapyrroles and colloidal TiO2 has been investigated using femtosecond transient absorption spectroscopy. Specifically, this work explores the not well-understood influence of the availability of states on the HET reaction. This problem is addressed by measuring electron injection times as a function of the energy difference between the LUMO and the conduction band of TiO2. The change in the energy alignment was done using two experimental strategies. The first one employs a recently synthesized phlorin with two different excited states above the conduction band of TiO2. This molecule allows comparing HET rates from two different excited states. The second strategy measures the electron injection rates after exciting the same electronic state of a set of specially designed porphyrins. The novelty of the approach is that the difference in energy alignment is attained by the introduction of dipole groups within the bridge group of the molecule. This strategy generates a difference in energy alignment of up to 200 meV. The reported measurements were carried in a high vacuum environment with an apparatus capable of resolving sub 30 fs processes. Disentanglement of the electron transfer processes was done, after careful study of the relaxation dynamics of the molecules in solution, by monitoring the decay of the excited state absorption and the rise of the cation spectral signatures. Within our time resolution, our results show that the increase in the availability of acceptor states does not influence the electron injection dynamics. The results suggest that the injection process takes place into a spectrum of states different from those obtained by steady state calculations.

  10. Electronic Properties of Free-Standing Surfactant-Capped Lead Halide Perovskite Nanocrystals Isolated in Vacuo.

    PubMed

    Milosavljevic, Aleksandar R; Bozanic, Dusan; Sadhu, Subha; Vukmirovic, Nenad; Dojcilovic, Radovan; Sapkota, Pitambar; Huang, Weixin; Bozek, John D; Nicolas, Christophe; Nahon, Laurent; Ptasinska, Sylwia

    2018-06-14

    We report an investigation of lead halide perovskite CH3NH3PbBr3 nanocrystals and associated ligand molecules, by combining several different state-of-the-art experimental techniques, including synchrotron radiation based XPS and VUV PES of free-standing nanocrystals isolated in vacuum. By using this novel approach for perovskite materials we could directly obtain a complete band alignment to vacuum of both CH3NH3PbBr3 nanocrystals and the ligands widely used in their preparation. We discuss possible influence of the ligand molecules to apparent perovskite properties, and we compare the electronic properties of nanocrystals to that of bulk material. The experimental results were supported by DFT calculations.

  11. Characterization of an in-vacuum PILATUS 1M detector.

    PubMed

    Wernecke, Jan; Gollwitzer, Christian; Müller, Peter; Krumrey, Michael

    2014-05-01

    A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four-crystal monochromator beamline of the PTB at the electron storage ring BESSY II in Berlin, Germany. Owing to its windowless operation, the detector can be used in the entire photon energy range of the beamline from 10 keV down to 1.75 keV for small-angle X-ray scattering (SAXS) experiments and anomalous SAXS at absorption edges of light elements. The radiometric and geometric properties of the detector such as quantum efficiency, pixel pitch and module alignment have been determined with low uncertainties. The first grazing-incidence SAXS results demonstrate the superior resolution in momentum transfer achievable at low photon energies.

  12. Extreme ultraviolet (EUV) and FUV calibration facility for special sensor ultraviolet limb imager (SSULI)

    NASA Astrophysics Data System (ADS)

    Boyer, Craig N.; Osterman, Steven N.; Thonnard, Stefan E.; McCoy, Robert P.; Williams, J. Z.; Parker, S. E.

    1994-09-01

    A facility for calibrating far ultraviolet and extreme ultraviolet instruments has recently been completed at the Naval Research Laboratory. Our vacuum calibration vessel is 2-m in length, 1.67-m in diameter, and can accommodate optical test benches up to 1.2-m wide by 1.5-m in length. A kinematically positioned frame with four axis precision pointing capability of 10 microns for linear translation and .01 degrees for rotation is presently used during vacuum optical calibration of SSULI. The chamber was fabricated from 304 stainless steel and polished internally to reduce surface outgassing. A dust-free environment is maintained at the rear of the vacuum chamber by enclosing the 2-m hinged vacuum access door in an 8 ft. by 8 ft. class 100 clean room. Every effort was made to obtain an oil-free environment within the vacuum vessel. Outgassing products are continually monitored with a 1 - 200 amu residual gas analyzer. An oil-free claw and vane pump evacuates the chamber to 10-2 torr through 4 in. diameter stainless steel roughing lines. High vacuum is achieved and maintained with a magnetically levitated 480 l/s turbo pump and a 3000 l/s He4 cryopump. Either of two vacuum monochrometers, a 1-m f/10.4 or a 0.2-m f/4.5 are coaxially aligned with the optical axis of the chamber and are used to select single UV atomic resonance lines from a windowless capillary or penning discharge UV light source. A calibrated channeltron detector is coaxially mounted with the SSULI detector during calibration. All vacuum valves, the cooling system for the cryopump compressor, and the roughing pump are controlled through optical fibers which are interfaced to a computer through a VME board. Optical fibers were chosen to ensure that complete electrical isolation is maintained between the computer and the vacuum system valves-solenoids and relays.

  13. Alignment limit of the NMSSM Higgs sector

    DOE PAGES

    Carena, Marcela; Haber, Howard E.; Low, Ian; ...

    2016-02-17

    The Next-to-Minimal Supersymmetric extension of the Standard Model (NMSSM) with a Higgs boson of mass 125 GeV can be compatible with stop masses of order of the electroweak scale, thereby reducing the degree of fine-tuning necessary to achieve electroweak symmetry breaking. Moreover, in an attractive region of the NMSSM parameter space, corresponding to the \\alignment limit" in which one of the neutral Higgs fields lies approximately in the same direction in field space as the doublet Higgs vacuum expectation value, the observed Higgs boson is predicted to have Standard- Model-like properties. We derive analytical expressions for the alignment conditions andmore » show that they point toward a more natural region of parameter space for electroweak symmetry breaking, while allowing for perturbativity of the theory up to the Planck scale. Additionally, the alignment limit in the NMSSM leads to a well defined spectrum in the Higgs and Higgsino sectors, and yields a rich and interesting Higgs boson phenomenology that can be tested at the LHC. Here, we discuss the most promising channels for discovery and present several benchmark points for further study.« less

  14. A minimal model of neutrino flavor

    NASA Astrophysics Data System (ADS)

    Luhn, Christoph; Parattu, Krishna Mohan; Wingerter, Akın

    2012-12-01

    Models of neutrino mass which attempt to describe the observed lepton mixing pattern are typically based on discrete family symmetries with a non-Abelian and one or more Abelian factors. The latter so-called shaping symmetries are imposed in order to yield a realistic phenomenology by forbidding unwanted operators. Here we propose a supersymmetric model of neutrino flavor which is based on the group T 7 and does not require extra {Z} N or U(1) factors in the Yukawa sector, which makes it the smallest realistic family symmetry that has been considered so far. At leading order, the model predicts tribimaximal mixing which arises completely accidentally from a combination of the T 7 Clebsch-Gordan coefficients and suitable flavon alignments. Next-to-leading order (NLO) operators break the simple tribimaximal structure and render the model compatible with the recent results of the Daya Bay and Reno collaborations which have measured a reactor angle of around 9°. Problematic NLO deviations of the other two mixing angles can be controlled in an ultraviolet completion of the model. The vacuum alignment mechanism that we use necessitates the introduction of a hidden flavon sector that transforms under a {Z} 6 symmetry, thereby spoiling the minimality of our model whose flavor symmetry is then T 7 × {Z} 6.

  15. RF cavity design and qualification for proton accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teotia, Vikas; Malhotra, Sanjay; Ukarde, Priti

    Alvarez type Drift Tube Linac (DTL) is used for acceleration of proton beam in low energy section of beta ranging from 0.04 to 0.40. DTL is cylindrical RF cavity resonating in TM010 mode at 352.21 MHz frequency. It consists of array of drift tubes arranged ensuring that DTL centre and Drift Tube centre are concentric. The Drift Tubes also houses Permanent Magnet Quadrupole for transverse focusing of proton beam. A twelve cell prototype of DTL section is designed, developed and fabricated at Bhabha Atomic Research Centre, Trombay. Complete DTL accelerator consists of eight such DTL sections. High frequency microwave simulationsmore » are carried out in SOPRANO, vector fields and COMSOL simulation software. This prototype DTL is 1640.56 mm long cavity with 520 mm ID, 600 mm OD and consists of eleven Drift Tubes, two RF end flanges, three slug tuners, six post couplers, three RF field monitors, one RF waveguide coupler, two DN100 vacuum flanges and DTL tank platform with alignment features. Girder based Drift tube mounting arrangement utilizing uncompressing energy of disc springs for optimum combo RF-vacuum seal compression is worked out and implemented. This paper discusses design of this RF vacuum cavity operating at high accelerating field gradient in ultra-high vacuum. Detailed vacuum design and results of RF and vacuum qualifications are discussed. Results on mechanical accuracy achieved on scaled pre-prototype are also presented. Paper summarizes the engineering developments carried out for this RF cavity and brings out the future activities proposed in indigenous development of high gradient RF cavities for ion accelerators. (author)« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Sangkyu; Park, Hun; Paik, Ungyu

    We have discovered a methodology to realize the fabrication of flexible metal oxide film using two-dimensional (2D) nanosheets. Atomic scale titanium oxide (TiO{sub x}) nanosheets were exfoliated from bulk TiO{sub x} powder that had a layered structure via the modified Sasaki’s method. The vacuum-assisted filtration generates films with laterally aligned TiO{sub x} nanosheets. The 2D sheet-like structure and hydrophilic nature of TiO{sub x} nanosheets enables the film consisting of TiO{sub x} nanosheets to be bendable. Also, we demonstrate the fabrication of electrochemical capacitors using this film. The mechanically flexible metal oxide film is expected to open up the possibility ofmore » fabricating flexible energy storage devices from 2D metal oxide nanosheets. - Graphical abstract: The modified Sasaki’s method, combined process of hydrothermal reaction and bulky ion exchange, enables to obtain TiO{sub x} monolayer nanosheets. The vacuum-assisted filtration generates bendable films with laterally aligned TiO{sub x} nanosheets. Also, we demonstrate the fabrication of electrochemical capacitors using this film. - Highlights: • TiO{sub x} single sheets, a novel 2-dimensional material, were exfoliated from bulk powders via the modified Sasaki’s method. • In our method, the acid treatment of TiO{sub x} bulk powders was simply modified by applying the hydrothermal reaction. • Then, the delamination procedures of large cation exchange were conducted following the method proposed by Sasaki et al. • Reassembly of TiO{sub x} sheets into flexible free-standing films was simply achieved via vacuum assisted filtration method. • TiO{sub x} films were used as a flexible supercapaictor electrode material.« less

  17. Band alignment at the Cu2ZnSn(SxSe1-x)4/CdS interface

    NASA Astrophysics Data System (ADS)

    Haight, Richard; Barkhouse, Aaron; Gunawan, Oki; Shin, Byungha; Copel, Matt; Hopstaken, Marinus; Mitzi, David B.

    2011-06-01

    Energy band alignments between CdS and Cu2ZnSn(SxSe1-x)4 (CZTSSe) grown via solution-based and vacuum-based deposition routes were studied as a function of the [S]/[S+Se] ratio with femtosecond laser ultraviolet photoelectron spectroscopy, photoluminescence, medium energy ion scattering, and secondary ion mass spectrometry. Band bending in the underlying CZTSSe layer was measured via pump/probe photovoltage shifts of the photoelectron spectra and offsets were determined with photoemission under flat band conditions. Increasing the S content of the CZTSSe films produces a valence edge shift to higher binding energy and increases the CZTSSe band gap. In all cases, the CdS conduction band offsets were spikes.

  18. In situ focus characterization by ablation technique to enable optics alignment at an XUV FEL source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerasimova, N.; Dziarzhytski, S.; Weigelt, H.

    2013-06-15

    In situ focus characterization is demonstrated by working at an extreme ultraviolet (XUV) free-electron laser source using ablation technique. Design of the instrument reported here allows reaching a few micrometres resolution along with keeping the ultrahigh vacuum conditions and ensures high-contrast visibility of ablative imprints on optically transparent samples, e.g., PMMA. This enables on-line monitoring of the beam profile changes and thus makes possible in situ alignment of the XUV focusing optics. A good agreement between focal characterizations retrieved from in situ inspection of ablative imprints contours and from well-established accurate ex situ analysis with Nomarski microscope has been observedmore » for a typical micro-focus experiment.« less

  19. Effects of magnetic field and pressure in magnetoelastic stress reconfigurable thin film resonators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Staruch, M.; Bussmann, K.; Finkel, P.

    2015-07-20

    Free-standing CoFe thin-film doubly clamped stress reconfigurable resonators were investigated as a function of magnetic field and pressure. A large uniaxial anisotropy resulting from residual uniaxial tensile stress, as revealed from magnetic hysteresis loops, leads to an easy magnetization axis aligned along the length of the beams. The quality factor of the driven resonator beams under vacuum is increased by 30 times, leading to an enhanced signal-to-noise ratio and a predicted reduction in the intrinsic magnetic noise by a factor of 6, potentially reaching as low as ∼25 pT/√Hz at 1 Torr. Stress reconfigurable sensors operating under vacuum could thus furthermore » improve the limit of detection and advance development of magnetic field sensing technology.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ioakeimidis, Apostolos; Christodoulou, Christos; Lux-Steiner, Martha

    In this work we fabricate all-vacuum processed methyl ammonium lead halide perovskite by a sequence of physical vapour deposition of PbI{sub 2} and chemical vapour deposition (CVD) of CH{sub 3}NH{sub 3}I under a static atmosphere. We demonstrate that for higher deposition rate the (001) planes of PbI{sub 2} film show a higher degree of alignment parallel to the sample's surface. From X-ray diffraction data of the resulted perovskite film we derive that the intercalation rate of CH{sub 3}NH{sub 3}I is fostered for PbI{sub 2} films with higher degree of (001) planes alignment. The stoichiometry of the produced perovskite film ismore » also studied by Hard X-ray photoelectron spectroscopy measurements. Complete all-vacuum perovskite solar cells were fabricated on glass/ITO substrates coated by an ultra-thin (5 nm) Zn-phthalocyanine film as hole selective layer. A dependence of residual PbI{sub 2} on the solar cells performance is displayed, while photovoltaic devices with efficiency up to η=11.6% were achieved. - Graphical abstract: A two-step PVD/CVD processed perovskite film with the CVD intercalation rate of CH{sub 3}NCH{sub 3} molecules been fostered by increasing the PVD rate of PbI{sub 2} and prolonging the CVD time. - Highlights: • A simple PVD/CVD process for perovskite film production. • Increased PVD rate yields better alignment of the PbI{sub 2} (001) crystallite planes. • CH{sub 3}NH{sub 3}I intercalation process fostered by increased PbI{sub 2} PVD rate. • Stoichiometric CH{sub 3}NH{sub 3}PbI{sub 3} suitable as absorber in photovoltaic applications • Reduced PbI{sub 2} residue at the bottom of CH{sub 3}NH{sub 3}PbI{sub 3} improves device performance.« less

  1. Fabrication of compact electron gun for 6 MeV X-ray source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghodke, S.R.; Barnwal, Rajesh; Kumar, Mahendra, E-mail: ghodke_barc@yahoo.co.in

    The 6 MeV X-Ray source for container cargo scanning application has been designed and developed by the Accelerator and Pulse Power Division, BARC, Mumbai. This compact linac has been designed as a mobile system, to be mounted on a moving container. In linac-based cargo-scanning system, to work electron gun on a movable container, it has to be robust. Electron gun is to work at 10{sup -7} mbar vacuum and 2000 degree Celsius temperature. An effort is made to engineer the gun assembly to make it more robust and aligned. The linac acts as the source of X-rays, which fall onmore » the cargo and are then detected by the detector system. Many components are indigenously developed like grid, insulating ring, Tungsten filament and filament guide, which are made from alumina ceramic and Tantalum which is to work at 1500 degree Celsius. Filament connector is made from Invar to reduce heat loss and to make rigid connection. It was CNC machined and wire cut by EDM. Invar and Copper electrode feed through is shrink fitted with the help of liquid Nitrogen. Shrink fit tolerances of 15 micrometer are achieved by jig boring machining processes. Tantalum cup for LaB6 cathode and heat shield are made from die and punch mechanism. For alignment of electron emitter with beam axis this Tantalum cup is a crucial component. Electron gun is assembled and aligned its components with the help of precision jigs. The whole assembly was Helium leak tested by MSLD up to 4 x 10{sup -10} mbar.l/s vacuum, no leak was found. This paper will describe the machining, Tantalum cup forming, ceramic components development, heat shields, ceramic feed through etc of electron gun. (author)« less

  2. BRIGHTEST SATELLITE GALAXY ALIGNMENT OF SLOAN DIGITAL SKY SURVEY GALAXY GROUPS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Zhigang; Wang Yougang; Chen Xuelei

    2013-05-01

    We study the alignment signal between the distribution of the brightest satellite galaxies (BSGs) and the major axes of their host groups using the Sloan Digital Sky Survey group catalog constructed by Yang et al. After correcting for the effect of group ellipticity, a statistically significant ({approx}5{sigma}) major-axis alignment is detected and the alignment angle is found to be 43. Degree-Sign 0 {+-} 0. Degree-Sign 4. More massive and richer groups show a stronger BSG alignment. The BSG alignment around blue brightest central galaxies (BCGs) is slightly stronger than that around red BCGs. Red BSGs have a much stronger major-axismore » alignment than blue BSGs. Unlike BSGs, other satellites do not show very significant alignment with their group's major axis. We further explore BSG alignment using the semi-analytic model (SAM) constructed by Guo et al. In general, we found good agreement of the model with observations: BSGs in the SAM show a strong major-axis alignment that depends on group mass and richness in the same way as in observations and none of the other satellites exhibit prominent alignment. However, a discrepancy also exists in that the SAM shows a BSG color dependence opposite of that in observations, which is most probably induced by a missing large-scale environment ingredient in the SAM. The combination of two popular scenarios can explain the BSG alignment we detected. First, satellites merged into the group along the surrounding filaments, which are strongly aligned with the major axis of the group. Second, BSGs entered their host group more recently than other satellites, so they have preserved more information about their assembling history and major-axis alignment. In the SAM, we found positive evidence for the second scenario in the fact that BSGs merged into groups statistically more recently than other satellites. We also found that most of the BSGs (80%) were BCGs before they merged into groups and earlier merging BSGs tend to be closer to their BCGs than other BSGs. On the other hand, although the BSG color dependence in observations is the opposite of that in the SAM, it might also indicate that the first scenario is a good explanation.« less

  3. Evacuated optical structure comprising optical bench mounted to sidewall of vacuum chamber in a manner which inhibits deflection and rotation of the optical bench

    DOEpatents

    Bowers, Joel M.

    1994-01-01

    An improved evacuated optical structure is disclosed comprising an optical bench mounted in a vacuum vessel in a manner which inhibits transmission of movement of the vacuum vessel to the optical bench, yet provides a compact and economical structure. The vacuum vessel is mounted, through a sidewall thereof, to a support wall at four symmetrically positioned and spaced apart areas, each of which comprises a symmetrically positioned group of mounting structures passing through the sidewall of the vacuum vessel. The optical bench is pivotally secured to the vacuum vessel by four symmetrically spaced apart bolts and spherical bearings, each of which is centrally positioned within one of the four symmetrically positioned groups of vacuum vessel mounting structures. Cover plates and o-ring seals are further provided to seal the vacuum vessel mounting structures from the interior of the vacuum vessel, and venting bores are provided to vent trapped gases in the bores used to secure the cover plates and o-rings to the vacuum vessel. Provision for detecting leaks in the mounting structures from the rear surface of the vacuum vessel sidewall facing the support wall are also provided. Deflection to the optical bench within the vacuum vessel is further minimized by tuning the structure for a resonant frequency of at least 100 Hertz.

  4. Evacuated optical structure comprising optical bench mounted to sidewall of vacuum chamber in a manner which inhibits deflection and rotation of the optical bench

    DOEpatents

    Bowers, J.M.

    1994-04-19

    An improved evacuated optical structure is disclosed comprising an optical bench mounted in a vacuum vessel in a manner which inhibits transmission of movement of the vacuum vessel to the optical bench, yet provides a compact and economical structure. The vacuum vessel is mounted, through a sidewall thereof, to a support wall at four symmetrically positioned and spaced apart areas, each of which comprises a symmetrically positioned group of mounting structures passing through the sidewall of the vacuum vessel. The optical bench is pivotally secured to the vacuum vessel by four symmetrically spaced apart bolts and spherical bearings, each of which is centrally positioned within one of the four symmetrically positioned groups of vacuum vessel mounting structures. Cover plates and o-ring seals are further provided to seal the vacuum vessel mounting structures from the interior of the vacuum vessel, and venting bores are provided to vent trapped gases in the bores used to secure the cover plates and o-rings to the vacuum vessel. Provision for detecting leaks in the mounting structures from the rear surface of the vacuum vessel sidewall facing the support wall are also provided. Deflection to the optical bench within the vacuum vessel is further minimized by tuning the structure for a resonant frequency of at least 100 Hertz. 10 figures.

  5. A high-vacuum wound drainage system reduces pain and length of treatment for pediatric soft tissue abscesses.

    PubMed

    Yang, Chao; Wang, Shan; Li, Chang-Chun; Kong, Xiang-Ru; Zhao, Zhenzhen; Deng, Xiao-Bin; Peng, Liang; Zhang, Jun

    2017-02-01

    Open incision and drainage (I&D) and wound packing is accepted as the standard treatment for soft tissue abscesses. However, conventional I&D has a number of problems in practice which prompt us to improve the I&D methods that would minimize the pain associated with packing during dressing changes. In order to compare the pain associated with dressing changes in the conventional I&D group to the vacuum system group and the treatment time of both groups, we performed a randomized trial in pediatric patients between 0 and 18 years of age who are undergoing abscess drainage in the operating room from April 2011 to April 2015. Patients treated with open I&D (n = 648) were compared to those treated with placement of high-vacuum wound drainage system (n = 776) through the abscess cavities. Both groups received equivalent antibiotic treatment, and all patients were followed up in the outpatient clinics until the infection has been resolved. The mean FACES scale pain scores were significantly higher in the open I&D group than in the vacuum system group. The vacuum system group had a shorter length of stay and less need for community doctor or outpatient dressing changes than the open I&D group (p < 0.001). No recurrent abscesses were observed in the vacuum system group, and 10 patients in the open I&D group required another drainage at the exact same location. High-vacuum wound drainage system was an efficient and safe alternative to the traditional I&D for community-acquired soft tissue abscesses with few complications in short term. What is Known: • Open incision and drainage (I&D) followed by irrigation and wound packing is the standard treatment for soft tissue abscesses. • The painful daily packing may cause emotional trauma to the child and lead to an unwelcoming challenge to the caretakers and health care providers. What is New: • We modified the method of I&D by adding primary suturing of the wound and placement of a high-vacuum wound drainage system. • This technique was proved to be an efficient and safe alternative to the traditional I&D method for soft tissue abscesses with small complications in short term.

  6. KiwiSpec: The Design and Performance of a High Resolution Echelle Spectrograph for Astronomy

    NASA Astrophysics Data System (ADS)

    Gibson, Steven Ross

    This document describes the design, analysis, construction and testing of KiwiSpec, a fibre-fed, high resolution astronomical spectrograph of an asymmetric white pupil design. The instrument employs an R4, 31.6 groove mm-1 échelle grating for primary dispersion and a 725 lines mm-1 volume phase holographic (VPH) based grism for cross-dispersion. Two versions of the prototype were designed and constructed: an 'in-air' prototype, and a prototype featuring a vacuum chamber (to increase the stability of the instrument). The KiwiSpec optical design is introduced, as well as a description of the theory behind a cross-dispersed échelle spectrograph. The results of tolerancing the optical design are reported for alignment, optical fabrication, and optical surface quality groups of parameters. The optical windows of an iodine cell are also toleranced. The opto-mechanical mounts of both prototypes are described in detail, as is the design of the vacuum chamber system. Given the goal of 1 m/s radial velocity stability, analyses were undertaken to determine the allowable amount of movement of the vacuum windows, and to determine the allowable changes in temperature and pressure within and outside of the vacuum chamber. The spectral efficiency of the instrument was estimated through a predictive model; this was calculated for the as-built instrument and also for an instrument with ideal, high-efficiency coatings. Measurements of the spectral efficiency of various components of the instrument are reported, as well as a description of the measurement system developed to test the efficiency of VPH gratings. On-sky efficiency measurements from use of KiwiSpec on the 1-m McLellan telescope at Mt John University Observatory are reported. Two possible exposure meter locations are explored via an efficiency model, and also through the measurement of the zero-order reflectivity of the échelle grating. Various stability aspects of the design are investigated. These include the stability of the optical mounts with temperature changes, and also the effect of the expansion and contraction of the supporting optical tables. As well, the stability of the in-air prototype was determined through measurement of the movement of thorium-argon emission lines within spectra as the temperature, atmospheric pressure and relative humidity (naturally) varied. Current and planned testing for determining the stability of the vacuum chamber prototype is discussed.

  7. A Boresight Adjustment Mechanism for use on Laser Altimeters

    NASA Technical Reports Server (NTRS)

    Hakun, Claef; Budinoff, Jason; Brown, Gary; Parong, Fil; Morell, Armando

    2004-01-01

    This paper describes the development of the Boresight Adjustment Mechanism (BAM) for the Geoscience Laser Altimeter System (GLAS) Instrument. The BAM was developed late in the integration and test phase of the GLAS instrument flight program. Thermal vacuum tests of the GLAS instrument indicated that the instrument boresight alignment stability over temperature may be marginal. To reduce the risk that GLAS may not be able to meet the boresight alignment requirements, an intensive effort was started to develop a BAM. Observatory-level testing and further evaluation of the boresight alignment data indicated that sufficient margin could be obtained utilizing existing instrument resources and therefore the BAM was never integrated onto the GLAS Instrument. However, the BAM was designed fabricated and fully qualified over a 4 month timeframe to be capable of precisely steering (< 1 arcsec over 300 arcsec) the output of three independent lasers to ensure the alignment between the transmit and receive paths of the GLAS instrument. The short timeline for the development of the mechanism resulted in several interesting design solutions. This paper discusses the requirement definition, design, and testing processes of the BAM development effort, how the design was affected by the extremely tight development schedule, and the lessons learned throughout the process.

  8. MUSE optical alignment procedure

    NASA Astrophysics Data System (ADS)

    Laurent, Florence; Renault, Edgard; Loupias, Magali; Kosmalski, Johan; Anwand, Heiko; Bacon, Roland; Boudon, Didier; Caillier, Patrick; Daguisé, Eric; Dubois, Jean-Pierre; Dupuy, Christophe; Kelz, Andreas; Lizon, Jean-Louis; Nicklas, Harald; Parès, Laurent; Remillieux, Alban; Seifert, Walter; Valentin, Hervé; Xu, Wenli

    2012-09-01

    MUSE (Multi Unit Spectroscopic Explorer) is a second generation VLT integral field spectrograph (1x1arcmin² Field of View) developed for the European Southern Observatory (ESO), operating in the visible wavelength range (0.465-0.93 μm). A consortium of seven institutes is currently assembling and testing MUSE in the Integration Hall of the Observatoire de Lyon for the Preliminary Acceptance in Europe, scheduled for 2013. MUSE is composed of several subsystems which are under the responsibility of each institute. The Fore Optics derotates and anamorphoses the image at the focal plane. A Splitting and Relay Optics feed the 24 identical Integral Field Units (IFU), that are mounted within a large monolithic instrument mechanical structure. Each IFU incorporates an image slicer, a fully refractive spectrograph with VPH-grating and a detector system connected to a global vacuum and cryogenic system. During 2011, all MUSE subsystems were integrated, aligned and tested independently in each institute. After validations, the systems were shipped to the P.I. institute at Lyon and were assembled in the Integration Hall This paper describes the end-to-end optical alignment procedure of the MUSE instrument. The design strategy, mixing an optical alignment by manufacturing (plug and play approach) and few adjustments on key components, is presented. We depict the alignment method for identifying the optical axis using several references located in pupil and image planes. All tools required to perform the global alignment between each subsystem are described. The success of this alignment approach is demonstrated by the good results for the MUSE image quality. MUSE commissioning at the VLT (Very Large Telescope) is planned for 2013.

  9. Vacuum extraction failure is associated with a large head circumference.

    PubMed

    Kabiri, Doron; Lipschuetz, Michal; Cohen, Sarah M; Yagel, Oren; Levitt, Lorinne; Herzberg, Shmuel; Ezra, Yossef; Yagel, Simcha; Amsalem, Hagai

    2018-04-24

    To determine whether large head circumference increases the risk of vacuum extraction failure. This EMR-based study included all attempted vacuum extractions performed in a tertiary center between January 2010 and June 2015. All term singleton live births were eligible. Cases were divided into four groups: head circumference ≥90th percentile both with birth weight ≥90th percentile and <90th percentile and fetal head circumference <90th percentile with birth weight ≥90th and <90th percentile. Risk of failed vacuum extraction was compared among these groups. Other neonatal and maternal parameters were also evaluated as potential risk factors. Multinomial multivariable regression provided adjusted odds ratio for vacuum extraction failure while controlling for potential confounders. During the study period, 48,007 deliveries met inclusion criteria, of which 3835 had an attempt at vacuum extraction. We identified 215 (5.6%) cases of vacuum extraction failure. The adjusted odds ratios (aOR) for vacuum extraction failure in cases of large fetal head circumference was 2.31 (95%CI, 1.7-3.15, p < .001). Primiparity, prolonged second stage and occipito-posterior presentation were also found to be significant risk factors for failed vacuum extraction. In this study, we found that large head circumference was associated with vacuum extraction failure rather than high birth weight.

  10. Pupil Alignment Considerations for Large, Deployable Space Telescopes

    NASA Technical Reports Server (NTRS)

    Bos, Brent J.; Ohl, Raymond G.; Kubalak, Daivd A.

    2011-01-01

    For many optical systems the properties and alignment of the internal apertures and pupils are not critical or controlled with high precision during optical system design, fabrication or assembly. In wide angle imaging systems, for instance, the entrance pupil position and orientation is typically unconstrained and varies over the system s field of view in order to optimize image quality. Aperture tolerances usually do not receive the same amount of scrutiny as optical surface aberrations or throughput characteristics because performance degradation is typically graceful with misalignment, generally only causing a slight reduction in system sensitivity due to vignetting. But for a large deployable space-based observatory like the James Webb Space Telescope (JWST), we have found that pupil alignment is a key parameter. For in addition to vignetting, JWST pupil errors cause uncertainty in the wavefront sensing process that is used to construct the observatory on-orbit. Furthermore they also open stray light paths that degrade the science return from some of the telescope s instrument channels. In response to these consequences, we have developed several pupil measurement techniques for the cryogenic vacuum test where JWST science instrument pupil alignment is verified. These approaches use pupil alignment references within the JWST science instruments; pupil imaging lenses in three science instrument channels; and unique pupil characterization features in the optical test equipment. This will allow us to verify and crosscheck the lateral pupil alignment of the JWST science instruments to approximately 1-2% of their pupil diameters.

  11. [Caesarean section with vacuum extraction of the head].

    PubMed

    Dimitrov, A; Pavlova, E; Krŭsteva, K; Nikolov, A

    2008-01-01

    The aim of the study is to investigate the benefits and the limits in using the soft cup vacuum extractor on the fetal scalp during the caesarean section. The prospective study includes 19 cases of caesarean sections (group A), with vacuum assisted delivery using the soft cup vacuum extractor on the fetal scalp (diameter 6 cm) and 25 cases (group B) of caesarean sections with usual, manual extraction of the head assisted by fundal compression. All of the patients had undergone a planned caesarean section on term in absence of uterine activity and preserved amniotic membranes. Our results doesn't show differences in the Apgar score on the first and 5-th minute in the newborns of the two groups. The duration of the scalp traction was significantly shorter (30 +/- 4 sec) in comparison to the classical manual extraction (53 +/- 21 sec). The mean duration for applying the vacuum cup was 10 sec and 25 sec for tractions. The total blood loose and total duration of the caesarean sections were shorter than in the control group. The applied traction with the vacuum cup was sufficient for head extraction and there was no need for additional fundal compression. In conclusion we consider that the extraction of the fetal head in high position in caesarean section with vacuum extractor is an easy, non traumatic and rapid method which can put away the need of rough and prolonged fundal compression and its consequences.

  12. Fetal macrosomia as a risk factor for shoulder dystocia during vacuum extraction.

    PubMed

    Herzberg, Shmuel; Kabiri, Doron; Mordechai, Tzlil; Haj Yahya, Rani; Chill, Henry; Levitt, Lorinne; Amsalem, Hagai; Ezra, Yossef

    2017-08-01

    Vacuum extraction of a macrosomic fetus is considered a risk factor for shoulder dystocia (SD). We evaluated maternal and fetal outcomes following vacuum extraction of macrosomic infants. A retrospective cohort study conducted in two large teaching hospitals. All deliveries of macrosomic infants by vacuum extraction and vaginal delivery were compared. The primary outcome measure was SD. Secondary outcome measures were severe perineal lacerations and postpartum hemorrhage. For statistical analysis, we used McNemar's test and χ 2 or Fisher's exact tests. Odds ratios were analyzed via a logistic regression model. From 2003 to 2013, there were 6019 (5.45%) deliveries of macrosomic fetuses, and 230 (0.21%) were delivered by vacuum extraction. There were 23 (10%) and seven (3.04%) cases of SD in the study and control groups, respectively. The risk of SD was significantly higher in the study group (p > 0.05). We found a significant association between SD and vacuum delivery [p = 0.003; OR = 3.54 (95% CI: 1.49-8.42)]. The composite adverse neonatal outcome rate was 6.5% (15/230) and 1.7% (4/230) in the study and control groups, respectively (p = 0.009). Vacuum extraction of a macrosomic infant is a risk factor for shoulder dystocia but not for postpartum hemorrhage or severe vaginal tears.

  13. The ties that bind: interorganizational linkages and physician-system alignment.

    PubMed

    Alexander, J A; Waters, T M; Burns, L R; Shortell, S M; Gillies, R R; Budetti, P P; Zuckerman, H S

    2001-07-01

    To examine the association between the degree of alignment between physicians and health care systems, and interorganizational linkages between physician groups and health care systems. The study used a cross sectional, comparative analysis using a sample of 1,279 physicians practicing in loosely affiliated arrangements and 1,781 physicians in 61 groups closely affiliated with 14 vertically integrated health systems. Measures of physician alignment were based on multiitem scales validated in previous studies and derived from surveys sent to individual physicians. Measures of interorganizational linkages were specified at the institutional, administrative, and technical core levels of the physician group and were developed from surveys sent to the administrator of each of the 61 physician groups in the sample. Two stage Heckman models with fixed effects adjustments in the second stage were used to correct for sample selection and clustering respectively. After accounting for sample selection, fixed effects, and group and individual controls, physicians in groups with more valued practice service linkages display consistently higher alignment with systems than physicians in groups that have fewer such linkages. Results also suggest that centralized administrative control lowers physician-system alignment for selected measures of alignment. Governance interlocks exhibited only weak associations with alignment. Our findings suggest that alignment generally follows resource exchanges that promote value-added contributions to physicians and physician groups while preserving control and authority within the group.

  14. Dark energy in the environments of the Local Group, the M 81 group, and the CenA group: the normalized Hubble diagram

    NASA Astrophysics Data System (ADS)

    Teerikorpi, P.; Chernin, A. D.; Karachentsev, I. D.; Valtonen, M. J.

    2008-05-01

    Context: Type Ia supernova observations on scales of thousands of Mpc show that the global expansion of the universe is accelerated by antigravity produced by the enigmatic dark energy contributing 3/4 of the total energy of the universe. Aims: Does antigravity act on small scales as well as large? As a continuation of our efforts to answer this crucial question we combine high accuracy observations of the galaxy flows around the Local Group and the nearby M 81 and CenA groups to observe the effect of the dark energy density on local scales of a few Mpc. Methods: We use an analytical model to describe non-uniform static space-time regions around galaxy groups. In this context it is useful to present the Hubble flow in a normalized Hubble diagram V/Hv Rv vs. r/R_v, where the vacuum Hubble constant Hv depends only on the cosmological vacuum density and the zero-gravity distance Rv depends on the vacuum density and on the mass of the galaxy group. We have prepared the normalized Hubble diagrams for the LG, M 81 and CenA group environments for different values of the assumed vacuum energy density, using a total of about 150 galaxies, for almost all of which the distances have been measured by the HST. Results: The normalized Hubble diagram, where we identify dynamically different regions, is in agreement with the standard vacuum density (Ωv = 0.77~h_70-2), the out-flow of galaxies clearly being controlled by the minimum energy condition imposed by the central mass plus the vacuum density. A high vacuum density 1.6~h_70-2 violates the minimum energy limit, while a low density 0.1~h_70-2 leaves the start of the Hubble flow around 1-2 Mpc with the slope close to the global value obscure. We also consider the subtle relation of the zero-gravity radius Rv to the zero-velocity distance R0 appearing in the usual retarded expansion around a mass M: in a vacuum-dominated flat universe R0 ≈ 0.76 R_v. Conclusions: The normalized Hubble diagram appears to be a good way to present and analyze physically different regions around mass clumps embedded in cosmological vacuum. The most natural interpretation of the diagram is that the local density of the dark energy is approximately equal to the density known from studies on global scales.

  15. Scrutinizing the alignment limit in two-Higgs-doublet models. II. mH=125 GeV

    NASA Astrophysics Data System (ADS)

    Bernon, Jérémy; Gunion, John F.; Haber, Howard E.; Jiang, Yun; Kraml, Sabine

    2016-02-01

    In the alignment limit of a multidoublet Higgs sector, one of the Higgs mass eigenstates aligns in field space with the direction of the scalar field vacuum expectation values, and its couplings approach those of the Standard Model (SM) Higgs boson. We consider C P -conserving two-Higgs-doublet models (2HDMs) of type I and type II near the alignment limit in which the heavier of the two C P -even Higgs bosons, H , is the SM-like state observed with a mass of 125 GeV, and the couplings of H to gauge bosons approach those of the SM. We review the theoretical structure and analyze the phenomenological implications of this particular realization of the alignment limit, where decoupling of the extra states cannot occur given that the lighter C P -even state h must, by definition, have a mass below 125 GeV. For the numerical analysis, we perform scans of the 2HDM parameter space employing the software packages 2hdmc and lilith, taking into account all relevant pre-LHC constraints, constraints from the measurements of the 125 GeV Higgs signal at the LHC, as well as the most recent limits coming from searches for other Higgs-like states. Implications for Run 2 at the LHC, including expectations for observing the other scalar states, are also discussed.

  16. Quantification of rectifications for the Northwestern University Flexible Sub-Ischial Vacuum Socket.

    PubMed

    Fatone, Stefania; Johnson, William Brett; Tran, Lilly; Tucker, Kerice; Mowrer, Christofer; Caldwell, Ryan

    2017-06-01

    The fit and function of a prosthetic socket depend on the prosthetist's ability to design the socket's shape to distribute load comfortably over the residual limb. We recently developed a sub-ischial socket for persons with transfemoral amputation: the Northwestern University Flexible Sub-Ischial Vacuum Socket. This study aimed to quantify the rectifications required to fit the Northwestern University Flexible Sub-Ischial Vacuum Socket to teach the technique to prosthetists as well as provide a computer-aided design-computer-aided manufacturing option. Development project. A program was used to align scans of unrectified and rectified negative molds and calculate shape change as a result of rectification. Averaged rectifications were used to create a socket template, which was shared with a central fabrication facility engaged in provision of Northwestern University Flexible Sub-Ischial Vacuum Sockets to early clinical adopters. Feedback regarding quality of fitting was obtained. Rectification maps created from 30 cast pairs of successfully fit Northwestern University Flexible Sub-Ischial Vacuum Sockets confirmed that material was primarily removed from the positive mold in the proximal-lateral and posterior regions. The template was used to fabricate check sockets for 15 persons with transfemoral amputation. Feedback suggested that the template provided a reasonable initial fit with only minor adjustments. Rectification maps and template were used to facilitate teaching and central fabrication of the Northwestern University Flexible Sub-Ischial Vacuum Socket. Minor issues with quality of initial fit achieved with the template may be due to inability to adjust the template to patient characteristics (e.g. tissue type, limb shape) and/or the degree to which it represented a fully mature version of the technique. Clinical relevance Rectification maps help communicate an important step in the fabrication of the Northwestern University Flexible Sub-Ischial Vacuum Socket facilitating dissemination of the technique, while the average template provides an alternative fabrication option via computer-aided design-computer-aided manufacturing and central fabrication.

  17. Microfocusing at the PG1 beamline at FLASH

    DOE PAGES

    Dziarzhytski, Siarhei; Gerasimova, Natalia; Goderich, Rene; ...

    2016-01-01

    The Kirkpatrick–Baez (KB) refocusing mirror system installed at the PG1 branch of the plane-grating monochromator beamline at the soft X-ray/XUV free-electron laser in Hamburg (FLASH) is designed to provide tight aberration-free focusing down to 4 µm × 6 µm full width at half-maximum (FWHM) on the sample. Such a focal spot size is mandatory to achieve ultimate resolution and to guarantee best performance of the vacuum-ultraviolet (VUV) off-axis parabolic double-monochromator Raman spectrometer permanently installed at the PG1 beamline as an experimental end-station. The vertical beam size on the sample of the Raman spectrometer, which operates without entrance slit, defines andmore » limits the energy resolution of the instrument which has an unprecedented design value of 2 meV for photon energies below 70 eV and about 15 meV for higher energies up to 200 eV. In order to reach the designed focal spot size of 4 µm FWHM (vertically) and to hold the highest spectrometer resolution, special fully motorized in-vacuum manipulators for the KB mirror holders have been developed and the optics have been aligned employing wavefront-sensing techniques as well as ablative imprints analysis. Lastly, aberrations like astigmatism were minimized. In this article the design and layout of the KB mirror manipulators, the alignment procedure as well as microfocus optimization results are presented.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dziarzhytski, Siarhei; Gerasimova, Natalia; Goderich, Rene

    The Kirkpatrick–Baez (KB) refocusing mirror system installed at the PG1 branch of the plane-grating monochromator beamline at the soft X-ray/XUV free-electron laser in Hamburg (FLASH) is designed to provide tight aberration-free focusing down to 4 µm × 6 µm full width at half-maximum (FWHM) on the sample. Such a focal spot size is mandatory to achieve ultimate resolution and to guarantee best performance of the vacuum-ultraviolet (VUV) off-axis parabolic double-monochromator Raman spectrometer permanently installed at the PG1 beamline as an experimental end-station. The vertical beam size on the sample of the Raman spectrometer, which operates without entrance slit, defines andmore » limits the energy resolution of the instrument which has an unprecedented design value of 2 meV for photon energies below 70 eV and about 15 meV for higher energies up to 200 eV. In order to reach the designed focal spot size of 4 µm FWHM (vertically) and to hold the highest spectrometer resolution, special fully motorized in-vacuum manipulators for the KB mirror holders have been developed and the optics have been aligned employing wavefront-sensing techniques as well as ablative imprints analysis. Lastly, aberrations like astigmatism were minimized. In this article the design and layout of the KB mirror manipulators, the alignment procedure as well as microfocus optimization results are presented.« less

  19. Development of a group work assessment pedagogy using constructive alignment theory.

    PubMed

    Croy, Suzanne R

    2018-02-01

    The purpose of this paper is to explore group work assessment underpinned by constructive alignment theory to develop a new assessment pedagogy. A review was undertaken of an existing module 'Mental Health Nursing 1', with student nurses participating in the BSc (Hons) Nursing Programme. Constructive alignment theory requires teachers to adopt a deep approach to learning where module learning outcomes are aligned with the teaching environment and modes of assessment. As the module progressed, reviewing the Mental Health Nursing 1 module became an excellent opportunity to begin to understand how constructive alignment theory can inform a group work assessment pedagogy. Working using a constructively aligned assessment process became a valuable learning experience for the module leader whilst at the same time revealed a gap in the research around the impact of constructively aligned teaching and group work assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Effect of mat pilates exercise on postural alignment and body composition of middle-aged women.

    PubMed

    Lee, Hyo Taek; Oh, Hyun Ok; Han, Hui Seung; Jin, Kwang Youn; Roh, Hyo Lyun

    2016-06-01

    [Purpose] This study attempted to examine whether Pilates is an effective exercise for improving the postural alignment and health of middle-aged women. [Subjects and Methods] The participants in this study were 36 middle-aged women (20 in the experimental group, 16 in the control group). The experimental group participated in Pilates exercise sessions three times a week for 12 weeks. Body alignment and composition measurements before and after applying the Pilates exercise program were performed with a body composition analyzer and a three-dimensional scanner. [Results] Postural alignment in the sagittal and horizontal planes was enhanced in the Pilates exercise group. Trunk alignment showed correlations with body fat and muscle mass. [Conclusion] The Pilates exercises are performed symmetrically and strengthen the deep muscles. Moreover, the results showed that muscle mass was correlated with trunk postural alignment and that the proper amount of muscle is critical in maintaining trunk postural alignment.

  1. New concept for in-line OLED manufacturing

    NASA Astrophysics Data System (ADS)

    Hoffmann, U.; Landgraf, H.; Campo, M.; Keller, S.; Koening, M.

    2011-03-01

    A new concept of a vertical In-Line deposition machine for large area white OLED production has been developed. The concept targets manufacturing on large substrates (>= Gen 4, 750 x 920 mm2) using linear deposition source achieving a total material utilization of >= 50 % and tact time down to 80 seconds. The continuously improved linear evaporation sources for the organic material achieve thickness uniformity on Gen 4 substrate of better than +/- 3 % and stable deposition rates down to less than 0.1 nm m/min and up to more than 100 nm m/min. For Lithium-Fluoride but also for other high evaporation temperature materials like Magnesium or Silver a linear source with uniformity better than +/- 3 % has been developed. For Aluminum we integrated a vertical oriented point source using wire feed to achieve high (> 150 nm m/min) and stable deposition rates. The machine concept includes a new vertical vacuum handling and alignment system for Gen 4 shadow masks. A complete alignment cycle for the mask can be done in less than one minute achieving alignment accuracy in the range of several 10 μm.

  2. The center of curvature optical assembly for the JWST primary mirror cryogenic optical test: optical verification

    NASA Astrophysics Data System (ADS)

    Wells, Conrad; Olczak, Gene; Merle, Cormic; Dey, Tom; Waldman, Mark; Whitman, Tony; Wick, Eric; Peer, Aaron

    2010-08-01

    The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) consists of a 6.6 m clear aperture, allreflective, three-mirror anastigmat. The 18-segment primary mirror (PM) presents unique and challenging assembly, integration, alignment and testing requirements. A full aperture center of curvature optical test is performed in cryogenic vacuum conditions at the integrated observatory level to verify PM performance requirements. The Center of Curvature Optical Assembly (CoCOA), designed and being built by ITT satisfies the requirements for this test. The CoCOA contains a multi wave interferometer, patented reflective null lens, actuation for alignment, full in situ calibration capability, coarse and fine alignment sensing systems, as well as a system for monitoring changes in the PM to CoCOA distance. Two wave front calibration tests are utilized to verify the low and Mid/High spatial frequencies, overcoming the limitations of the standard null/hologram configuration in its ability to resolve mid and high spatial frequencies. This paper will introduce the systems level architecture and optical test layout for the CoCOA.

  3. Probing the Energy Level Alignment and the Correlation with Open-Circuit Voltage in Solution-Processed Polymeric Bulk Heterojunction Photovoltaic Devices.

    PubMed

    Yang, Qing-Dan; Li, Ho-Wa; Cheng, Yuanhang; Guan, Zhiqiang; Liu, Taili; Ng, Tsz-Wai; Lee, Chun-Sing; Tsang, Sai-Wing

    2016-03-23

    Energy level alignment at the organic donor and acceptor interface is a key to determine the photovoltaic performance in organic solar cells, but direct probing of such energy alignment is still challenging especially for solution-processed bulk heterojunction (BHJ) thin films. Here we report a systematic investigation on probing the energy level alignment with different approaches in five commonly used polymer:[6,6]-phenyl-C71-butyric acid methyl ester (PCBM) BHJ systems. We find that by tuning the weight ratio of polymer to PCBM the electronic features from both polymer and PCBM can be obtained by photoemission spectroscopy. Using this approach, we find that some of the BHJ blends simply follow vacuum level alignment, but others show strong energy level shifting as a result of Fermi level pinning. Independently, by measuring the temperature-dependent open-circuit voltage (VOC), we find that the effective energy gap (Eeff), the energy difference between the highest occupied molecular orbital of the polymer donor (EHOMO-D) and lowest unoccupied molecular orbital of the PCBM acceptor (ELUMO-A), obtained by photoemission spectroscopy in all polymer:PCBM blends has an excellent agreement with the extrapolated VOC at 0 K. Consequently, the photovoltage loss of various organic BHJ photovoltaic devices at room temperature is in a range of 0.3-0.6 V. It is believed that the demonstrated direct measurement approach of the energy level alignment in solution-processed organic BHJ will bring deeper insight into the origin of the VOC and the corresponding photovoltage loss mechanism in organic photovoltaic cells.

  4. Emergent Embolization of Arterial Bleeding after Vacuum-Assisted Breast Biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischman, Aaron M., E-mail: aaron.fischman@mountsinai.org; Epelboym, Yan, E-mail: yan.epelboym@mssm.edu; Siegelbaum, Robert H., E-mail: rhsiegelbaum@gmail.com

    2012-02-15

    Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.

  5. Leakage and field emission in side-gate graphene field effect transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Bartolomeo, A., E-mail: dibant@sa.infn.it; Iemmo, L.; Romeo, F.

    We fabricate planar graphene field-effect transistors with self-aligned side-gate at 100 nm from the 500 nm wide graphene conductive channel, using a single lithographic step. We demonstrate side-gating below 1 V with conductance modulation of 35% and transconductance up to 0.5 mS/mm at 10 mV drain bias. We measure the planar leakage along the SiO{sub 2}/vacuum gate dielectric over a wide voltage range, reporting rapidly growing current above 15 V. We unveil the microscopic mechanisms driving the leakage, as Frenkel-Poole transport through SiO{sub 2} up to the activation of Fowler-Nordheim tunneling in vacuum, which becomes dominant at higher voltages. We report a field-emission current densitymore » as high as 1 μA/μm between graphene flakes. These findings are important for the miniaturization of atomically thin devices.« less

  6. FLUID PRESSURE AND CAM OPERATED VACUUM VALVE

    DOEpatents

    Batzer, T.H.

    1963-11-26

    An ultra-high vacuum valve that is bakable, reusable, and capable of being quickly opened and closed is described. A translationally movable valve gate having an annular ridge is adapted to contact an annular soft metal gasket disposed at the valve seat such that the soft metal gasket extends beyond the annular ridge on all sides. The valve gate is closed, by first laterally aligning the valve gate with the valve seat and then bringing the valve gate and valve seat into seating contact by the translational movement of a ramp-like wedging means that engages similar ramp-like stractures at the base of the valve gate to force the valve gate into essentially pressureless contact with the annular soft metal gasket. This gasket is then pressurized from beneath by a fluid thereby effecting a vacuura tight seal between the gasket and the ridge. (AEC)

  7. Cavity Control and Cooling of Nanoparticles in High Vacuum

    NASA Astrophysics Data System (ADS)

    Millen, James

    2016-05-01

    Levitated systems are a fascinating addition to the world of optically-controlled mechanical resonators. It is predicted that nanoparticles can be cooled to their c.o.m. ground state via the interaction with an optical cavity. By freeing the oscillator from clamping forces dissipation and decoherence is greatly reduced, leading to the potential to produce long-lived, macroscopically spread, mechanical quantum states, allowing tests of collapse models and any mass limit of quantum physics. Reaching the low pressures required to cavity-cool to the ground state has proved challenging. Our approach is to cavity cool a beam of nanoparticles in high vacuum. We can cool the c.o.m. motion of nanospheres, and control the rotation of nanorods, with the potential to produce cold, aligned nanostructures. Looking forward, we will utilize novel microcavities to enhance optomechanical cooling, preparing particles in a coherent beam ideally suited to ultra-high mass interferometry at 107 a.m.u.

  8. Hole-transport material variation in fully vacuum deposited perovskite solar cells

    NASA Astrophysics Data System (ADS)

    Polander, Lauren E.; Pahner, Paul; Schwarze, Martin; Saalfrank, Matthias; Koerner, Christian; Leo, Karl

    2014-08-01

    This work addresses the effect of energy level alignment between the hole-transporting material and the active layer in vacuum deposited, planar-heterojunction CH3NH3PbIx-3Clx perovskite solar cells. Through a series of hole-transport materials, with conductivity values set using controlled p-doping of the layer, we correlate their ionization potentials with the open-circuit voltage of the device. With ionization potentials beyond 5.3 eV, a substantial decrease in both current density and voltage is observed, which highlights the delicate energetic balance between driving force for hole-extraction and maximizing the photovoltage. In contrast, when an optimal ionization potential match is found, the open-circuit voltage can be maximized, leading to power conversion efficiencies of up to 10.9%. These values are obtained with hole-transport materials that differ from the commonly used Spiro-MeO-TAD and correspond to a 40% performance increase versus this reference.

  9. Effect of Nanotube Film Thickness on the Performance of Nanotube-Silicon Hybrid Solar Cells

    PubMed Central

    Tune, Daniel D.; Shapter, Joseph G.

    2013-01-01

    The results of measurements on solar cells made from randomly aligned thin films of single walled carbon nanotubes (SWCNTs) on n-type monocrystalline silicon are presented. The films are made by vacuum filtration from aqueous TritonX-100 suspensions of large diameter arc-discharge SWCNTs. The dependence of the solar cell performance on the thickness of the SWCNT film is shown in detail, as is the variation in performance due to doping of the SWCNT film with SOCl2. PMID:28348358

  10. Study on the key alignment technology of the catadioptric optical system

    NASA Astrophysics Data System (ADS)

    Song, Chong; Fu, Xing; Fu, Xi-hong; Kang, Xiao-peng; Liu, Kai

    2017-02-01

    Optical system alignment has a great influence on the whole system accuracy. In this paper, the processing of optical system alignment was mainly studied, the processing method of optics on the primary and secondary mirrors, front correction lens group and behind correction lens group with high precision centering lathe and internal focusing telescope. Then using the height indicator complete the system alignment of the primary mirror, secondary mirror, front correction group and behind correction group. Finally, based on the zygo interferometer detect the wavefront information. Using this alignment program for catadioptric optical system, the wavefront aberration of optical system, focal length, modulation transfer function (MTF) and other technical indicators have reached the requirements.

  11. Effect of mat pilates exercise on postural alignment and body composition of middle-aged women

    PubMed Central

    Lee, Hyo Taek; Oh, Hyun Ok; Han, Hui Seung; Jin, Kwang Youn; Roh, Hyo Lyun

    2016-01-01

    [Purpose] This study attempted to examine whether Pilates is an effective exercise for improving the postural alignment and health of middle-aged women. [Subjects and Methods] The participants in this study were 36 middle-aged women (20 in the experimental group, 16 in the control group). The experimental group participated in Pilates exercise sessions three times a week for 12 weeks. Body alignment and composition measurements before and after applying the Pilates exercise program were performed with a body composition analyzer and a three-dimensional scanner. [Results] Postural alignment in the sagittal and horizontal planes was enhanced in the Pilates exercise group. Trunk alignment showed correlations with body fat and muscle mass. [Conclusion] The Pilates exercises are performed symmetrically and strengthen the deep muscles. Moreover, the results showed that muscle mass was correlated with trunk postural alignment and that the proper amount of muscle is critical in maintaining trunk postural alignment. PMID:27390396

  12. The Function of Emulsions on the Biogenic Amine Formation and their Indices of Sea Bass Fillets (Dicentrarchus Labrax) Stored in Vacuum Packaging.

    PubMed

    Ozogul, Yesim; Durmus, Mustafa; Kuley Boga, Esmeray; Uçar, Yılmaz; Ozogul, Fatih

    2018-02-01

    The impacts of emulsions based on commercial oils on the biogenic amine formation and their indices of vacuumed packed sea bass fillets were investigated. The results showed that among biogenic amines, cadaverine, putrescine, spermidine, spermine, serotonin, dopamine, and agmatine were predominant amines in sea bass fillets stored under vacuum packaging. Significant differences (P < 0.05) in biogenic amines concentrations of vacuumed packed sea bass treated with emulsions were observed. All groups contained histamine lower than 5.0 mg/100 g, regarded as the allowable limit by the U.S. Food and Drug Administration. Polyamine levels were not affected by application of emulsion. Quality index (QI) showed an increase and after 14 d of storage it decreased in all groups. The control generally seemed to higher QI value than those of treatment groups except at 14 and 18 days while soybean and corn gave lower QI among treatment groups. Only biogenic amine index correlated with sensory acceptability of vacuumed packed sea bass, indicating that this index can be used for determination of the degree of spoilage of vacuumed packed sea bass. Emulsions extended the shelf-life (approximately 2 to 4 d) of vacuumed packed sea bass fillets by inhibiting microbial growth compared to the control. Emulsions have become popular since they are regarded as ideal carrier for the delivery of lipophilic substances due to the ease of preparation, small particle size, their enhanced bioavailability, and long term kinetic stability. They have been proven to be self-preserving antimicrobials due to bound water in their structure and thus no available water to microorganisms. Antimicrobial emulsions have potential applications in many fields because they are inexpensive, stable, and nontoxic agents. © 2018 Institute of Food Technologists®.

  13. Clinical impact of the disposable ventouse iCup® versus a metallic vacuum cup: a multicenter randomized controlled trial.

    PubMed

    Equy, Véronique; David-Tchouda, Sandra; Dreyfus, Michel; Riethmuller, Didier; Vendittelli, Françoise; Cabaud, Victoire; Langer, Bruno; Margier, Jennifer; Bosson, Jean-Luc; Schaal, Jean-Patrick

    2015-12-15

    Assisted vaginal delivery by vacuum extraction is frequent. Metallic resterilizible metallic vacuum cups have been routinely used in France. In the last few years a new disposable semi-soft vacuum extraction cup, the iCup, has been introduced. Our objective was to compare maternal and new-born outcomes between this disposable cup and the commonly used Drapier-Faure metallic cup. This was a multicenter prospective randomized controlled open clinical trial performed in the maternity units of five university hospitals and one community hospital in France from October 2009 to February 2013. We included consecutive eligible women with a singleton gestation of at least 37 weeks who required vacuum assisted delivery. Women were randomized to vacuum extraction using the iCup or usual Drapier-Faure metallic cup. The primary outcome was a composite criterion including both the risk of cup dysfunction and the most frequent maternal and neonatal harms: the use of other instruments after attempted vacuum extraction, caesarean section after attempted vacuum extraction, three detachments of the cup, caput succedaneum, cephalohaematoma, episiotomy and perineal tears. 335 women were randomized to the disposable cup and 333 to extraction using the metallic cup. There was no significant difference between the two groups for the primary outcome. However, failed instrumental delivery was more frequent in the disposable cup group, mainly due to detachment: 35.6 % vs 7.1 %, p < 0.0001. Conversely, perineal tears were more frequent in the metallic cup group, especially third or fourth grade perineal tears: 1.7 % versus 5.0 %, p = 0.003. There were no significant differences between the two groups concerning post-partum haemorrhage, transfer to a neonatal intensive care unit (NICU) or serious adverse events. While the disposable cup had more detachments and extraction failures than the standard metallic cup, this innovative disposable device had the advantage of fewer perineal injuries. www.clinicaltrials.gov : NCT01058200 on Jan. 27 2010.

  14. SO(10) × S 4 grand unified theory of flavour and leptogenesis

    NASA Astrophysics Data System (ADS)

    de Anda, Francisco J.; King, Stephen F.; Perdomo, Elena

    2017-12-01

    We propose a Grand Unified Theory of Flavour, based on SO(10) together with a non-Abelian discrete group S 4, under which the unified three quark and lepton 16-plets are unified into a single triplet 3'. The model involves a further discrete group ℤ 4 R × ℤ 4 3 which controls the Higgs and flavon symmetry breaking sectors. The CSD2 flavon vacuum alignment is discussed, along with the GUT breaking potential and the doublet-triplet splitting, and proton decay is shown to be under control. The Yukawa matrices are derived in detail, from renormalisable diagrams, and neutrino masses emerge from the type I seesaw mechanism. A full numerical fit is performed with 15 input parameters generating 19 presently constrained observables, taking into account supersymmetry threshold corrections. The model predicts a normal neutrino mass ordering with a CP oscillation phase of 260°, an atmospheric angle in the first octant and neutrinoless double beta decay with m ββ = 11 meV. We discuss N 2 leptogenesis, which fixes the second right-handed neutrino mass to be M 2 ≃ 2 × 1011 GeV, in the natural range predicted by the model.

  15. Comparative analysis of analgesic efficacy of selected physiotherapy methods in low back pain patients.

    PubMed

    Charłusz, Magdalena; Gasztych, Jowita; Irzmański, Robert; Kujawa, Jolanta

    2010-01-01

    Low back pain syndromes are one of the most frequent causes of movement limitation in populations of highly industrialized countries. They are listed as the main cause of inability to work among people of working age. Chronic pain and the associated limitation of movement underlie the quest for effective therapies. The use of ultrasound, LLLT, vacuum therapy with Ultra Reiz current in physical therapy of these patients prompts research over their effectiveness in the therapy of patients with low-back pain. The aim of the work was to evaluate the analgesic efficacy of LLLT, ultrasound, and vacuum therapy with Ultra Reiz current in patients with low back pain. The study involved 94 people divided into three groups (A,B,C). Group A (n=35) received a series of 10 low energy laser therapy sessions (wave length 808 nm, surface density of radiation 510 mW/cm(2), continuous wave form, scanning mode, a dose of 12 J/cm(2) on a surface of 100 cm(2) [10x10cm]). Patients in Group B (n=27) had ultrasound sessions with a wave intensity of 1 W/cm(2) for 3 minutes. Patients in Group C (n=32) underwent vacuum therapy (8 kPa) combined with Ultra Reiz current. Subjective pain assessment was carried out using a modified Latinen questionnaire and a visual analogue scale of pain intensity. Lumbosacral spine mobility was evaluated with the Schober test and the finger-to- floor test. In Group A, following low energy laser therapy, a statistically significant decrease in pain intensity was observed, together with decreased analgesic consumption compared to the other groups. In Group C, following vacuum therapy combined with Ultra Reiz currents, a significant decrease in the frequency of pain was observed together with increased physical activity compared to both Groups A and B, assessed according to a modified Laitinen pain indicator questionnaire. The biggest improvement in global spine mobility and lumbosacral flexion was observed in Group C (vacuum therapy plus Ultra Reiz current) compared to the other groups. However, the most significant improvement in lower spine extension was noted in Group B (ultrasound). 1. The study showed slightly higher analgesic efficacy of laser biostimulation in comparison to vacuum therapy combined with Ultra Reiz current in patients with low back pain. 2. A more prominent increase in lumbosacral spine mobility was observed after vacuum therapy combined with Ultra Reiz current and ultrasound therapy.

  16. Remote controlled vacuum joint closure mechanism

    DOEpatents

    Doll, D.W.; Hager, E.R.

    1984-02-22

    A remotely operable and maintainable vacuum joint closure mechanism for a noncircular aperture is disclosed. The closure mechanism includes an extendible bellows coupled at one end to a noncircular duct and at its other end to a flange assembly having sealed grooves for establishing a high vacuum seal with the abutting surface of a facing flange which includes an aperture forming part of the system to be evacuated. A plurality of generally linear arrangements of pivotally coupled linkages and piston combinations are mounted around the outer surface of the duct and aligned along the length thereof. Each of the piston/linkage assemblies is adapted to engage the flange assembly by means of a respective piston and is further coupled to a remote controlled piston drive shaft to permit each of the linkages positioned on a respective flat outer surface of the duct to simultaneously and uniformly displace a corresponding piston and the flange assembly with which it is in contact along the length of the duct in extending the bellows to provide a high vacuum seal between the movable flange and the facing flange. A plurality of latch mechanisms are also pivotally mounted on the outside of the duct. A first end of each of the latch mechanisms is coupled to a remotely controlled latch control shaft for displacing the latch mechanism about its pivot point. In response to the pivoting displacement of the latch mechanism, a second end thereof is displaced so as to securely engage the facing flange and maintain the high vacuum seal established by the displacement of the flange assembly and extension of the bellows without displacing the entire duct.

  17. The impact of training under different visual-spatial conditions on reverse-alignment laparoscopic skills development.

    PubMed

    Holznecht, Catherine; Schmidt, Travis; Gould, Jon

    2012-01-01

    Circumstances may arise during laparoscopic procedures in which alignment of the laparoscope and the instruments is off by 180°, creating a mirror image of the operative field. It has been shown that task performance is degraded under these reverse-alignment conditions, and that the magnitude of performance impairment is directly related to laparoscopic experience and skill. The aim of this study was to determine if reverse-alignment surgical skills could be developed through training. Twenty-two medical students were randomized to train in either reverse- or forward-alignment conditions on a standardized laparoscopic task in a video trainer (peg transfer). Baseline scores were attained for each group under both orientations. Subjects participated in three 1-h training sessions during an 8-week period. Post-training scores were then obtained under both alignment conditions. Pre and post-training scores were compared for users in each study group under both conditions. Post-training assessments in the forward orientation demonstrated that subjects in the forward-training group improved significantly compared to pre-testing, while the performance of subjects in the reverse-training group did not improve. Under reverse-alignment conditions, both groups improved on post-test assessment, with dramatic improvements observed for those in the reverse-training group. Laparoscopic novices can learn to adapt to a sensorimotor discordance in a simulated training environment. While it is possible that skills developed by training under standard forward-alignment conditions can be utilized in situations of extreme visual-spatial discordance, the intentional development of reverse-alignment skills by training under these conditions may prove beneficial to novice surgeons.

  18. [Vacuum-assisted therapy for various wound types including diabetic foot ulcer].

    PubMed

    Farah, Raymond; Gantus, Maher; Kogan, Leonid

    2011-03-01

    Vacuum is a noninvasive system that creates a localized controlled negative pressure environment. In this study, vacuum was provided by the V.A.C. Therapy system, which promotes wound healing by delayed primary or secondary intention through creating a moist wound environment, preparing the wound bed for closure, reducing edema, and promoting formation and perfusion of granulation tissue. Vacuum-assisted closure therapy is indicated for use in all care settings and for a variety of wound types including diabetic foot ulcers. The purpose of this study was to evaluate safety and clinical efficacy of negative pressure wound therapy (NPWT) compared with advanced moist wound therapy and standard treatment to treat foot ulcers in diabetic patients. This trial enrolled 43 patients; most of them were diabetic patients at any age with various skin ulcers and diabetic foot. These patients were divided into two groups, 17 patients were treated with vacuum and the 26 patients in the control group were treated with standard therapy including debridement. A greater proportion of foot and skin ulcers achieved complete ulcer closure with vacuum-assisted therapy p<0.001 compared with the standard therapy. Vacuum therapy significantly decreased the duration and frequency of admission p=0.032 and decreased the rate of amputation p<0.001. Results of our trial support other studies and demonstrate that vacuum is as safe as and more efficacious than standard therapy in the treatment of diabetic foot ulcers. A significantly greater number of patients achieved complete ulcer closure and granulation tissue formation with this therapy. The study group showed a significant reduction in the median time needed to heal ulcers, reduction of the number of admissions and amputation frequency.

  19. Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and patient-specific instrumentation in a low-volume setting.

    PubMed

    Suero, Eduardo M; Lueke, Ulrich; Stuebig, Timo; Hawi, Nael; Krettek, Christian; Liodakis, Emmanouil

    2018-04-25

    Procedure volume is an important determinant of total knee arthroplasty (TKA) outcomes. We aimed to determine whether computer navigation or patient-specific instrumentation (PSI) would improve postoperative alignment in a low-volume setting. PSI for TKA achieves better limb and implant alignment compared to conventional TKA and to computer navigated TKA. This is a retrospective cohort study of 385 primary TKAs (Women=59%. Mean age=67years. Mean BMI=30.1kg/m 2 ), which were performed using conventional instrumentation (n=117; 30%), computer navigation (n=209; 54%), or patient-specific instrumentation (n=59; 15%) in a low-volume center (<50 TKAs/year). The risk of postoperative leg and implant mechanical alignment outliers in the coronal plane (>3° from neutral), average alignment and operation time were assessed. The risk of postoperative mechanical alignment outliers (>3°) was reduced by 89% in the navigated group (4% outliers) compared to the conventional group (35%) (RR=0.11; p<0.0001). No significant improvement was observed in the PSI group (27%) (RR=0.91; p=0.772). The risk of postoperative femoral component coronal alignment outliers was reduced by 63% in the navigated group (11%) compared to the conventional group (31%) (RR=0.37; p=0.018). No significant reduction in outliers was observed in the PSI group (32%) (RR=1.08; p=0.816). There was a reduction in the risk of tibial component coronal malalignment of 66% in the navigated group (5%) compared to the conventional group (13%) (RR=0.33; p=0.070). There was a two-fold increase in the risk of tibial component alignment outliers in the PSI group (29%) (RR=1.94; p=0.110). Computer navigation improved postoperative alignment in TKA. No evidence of improved alignment was seen with patient-specific instrumentation. The routine use of patient-specific instrumentation in low-volume centers is not supported by the currently available data. Retrospective cohort study. Level IV. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  20. A Magnetohydrodynamic Modeling of the Interchange Cycle for Oblique Northward Interplanetary Magnetic Field

    NASA Astrophysics Data System (ADS)

    Watanabe, Masakazu; Fujita, Shigeru; Tanaka, Takashi; Kubota, Yasubumi; Shinagawa, Hiroyuki; Murata, Ken T.

    2018-01-01

    We perform numerical modeling of the interchange cycle in the magnetosphere-ionosphere convection system for oblique northward interplanetary magnetic field (IMF). The interchange cycle results from the coupling of IMF-to-lobe reconnection and lobe-to-closed reconnection. Using a global magnetohydrodynamic simulation code, for an IMF clock angle of 20° (measured from due north), we successfully reproduced the following features of the interchange cycle. (1) In the ionosphere, for each hemisphere, there appears a reverse cell circulating exclusively in the closed field line region (the reciprocal cell). (2) The topology transition of the magnetic field along a streamline near the equatorial plane precisely represents the magnetic flux reciprocation during the interchange cycle. (3) Field-aligned electric fields on the interplanetary-open separatrix and on the open-closed separatrix are those that are consistent with IMF-to-lobe reconnection and lobe-to-closed reconnection, respectively. These three features prove the existence of the interchange cycle in the simulated magnetosphere-ionosphere system. We conclude that the interchange cycle does exist in the real solar wind-magnetosphere-ionosphere system. In addition, the simulation revealed that the reciprocal cell described above is not a direct projection of the diffusion region as predicted by the "vacuum" model in which diffusion is added a priori to the vacuum magnetic topology. Instead, the reciprocal cell is a consequence of the plasma convection system coupled to the so-called NBZ ("northward Bz") field-aligned current system.

  1. Remote controlled vacuum joint closure mechanism

    DOEpatents

    Doll, David W.; Hager, E. Randolph

    1986-01-01

    A remotely operable and maintainable vacuum joint closure mechanism for a noncircular aperture is disclosed. The closure mechanism includes an extendible bellows coupled at one end to a noncircular duct and at its other end to a flange assembly having sealed grooves for establishing a high vacuum seal with the abutting surface of a facing flange which includes an aperture forming part of the system to be evacuated. A plurality of generally linear arrangements of pivotally coupled linkages and piston combinations are mounted around the outer surface of the duct and aligned along the length thereof. Each of the piston/linkage assemblies is adapted to engage the flange assembly by means of a respective piston and is further coupled to a remote controlled piston drive shaft to permit each of the linkages positioned on a respective flat outer surface of the duct to simultaneously and uniformly displace a corresponding piston and the flange assembly with which it is in contact along the length of the duct in extending the bellows to provide a high vacuum seal between the movable flange and the facing flange. A plurality of latch mechanisms are also pivotally mounted on the outside of the duct. A first end of each of the latch mechanisms is coupled to a remotely controlled latch control shaft for displacing the latch mechanism about its pivot point. In response to the pivoting displacement of the latch mechanism, a second end thereof is displaced so as to securely engage the facing flange.

  2. Bonded versus vacuum-formed retainers: a randomized controlled trial. Part 1: stability, retainer survival, and patient satisfaction outcomes after 12 months.

    PubMed

    Forde, Katherine; Storey, Madeleine; Littlewood, Simon J; Scott, Paul; Luther, Friedy; Kang, Jing

    2017-10-20

    There is a shortage of evidence on the best type of retainer. Evaluate upper and lower bonded retainers (BRs) versus upper and lower vacuum-formed retainers (VFRs) over 12 months, in terms of stability, retainer survival, and patient satisfaction. Two-arm parallel group multi-centre randomized controlled clinical trial. Sixty consecutive patients completing fixed appliance therapy and requiring retainers were recruited from 3 hospital departments. They were randomly allocated to either upper and lower labial segment BRs (n = 30) or upper and lower full-arch VFRs (n = 30). Primary outcome was stability. Secondary outcomes were retainer survival and patient satisfaction. A random sequence of treatment allocation was computer-generated and implemented by sealing in sequentially numbered opaque sealed envelopes independently prepared in advance. Patients, operators and outcome could not be blinded due to the nature of the intervention. Thirty patients received BRs (median [Mdn] age 16 years, inter-quartile range [IQR] = 2) and 30 received VFRs (Mdn age 17 years, IQR = 4). Baseline characteristics were similar between groups. At 12 months, there were no statistically significant inter-group differences in post-treatment change of maxillary labial segment alignment (BR = 1.1 mm, IQR = 1.56, VFR = 0.76 mm, IQR = 1.55, P = 0.61); however, there was greater post-treatment change in the mandibular VFR group (BR = 0.77 mm, IQR = 1.46, VFR = 1.69mm, IQR = 2.00, P = 0.008). The difference in maxillary retainer survival rates were statistically non-significant, P = 0.34 (BR = 63.6%, 239.3 days, 95% confidence interval [CI] = 191.1-287.5, VFR = 73.3%, 311.1 days, 95% CI = 278.3-344.29). The mandibular BR had a lower survival rate (P = 0.01) at 12 months (BR = 50%, 239.3 days 95% CI = 191.1-287.5, VFR = 80%, 324.9 days 95% CI = 295.4-354.4). More subjects with VFRs reported discomfort (P = 0.002) and speech difficulties (P = 0.004) but found them easier to clean than those with BRs (P = 0.001). Results are after 1 year and we do not know how much the removable retainers were worn. After 1 year, there is no evidence of a significant difference in stability or retainer survival in the maxilla. In the mandible, BRs are more effective at maintaining mandibular labial segment alignment, but have a higher failure rate. In comparison with patients wearing VFRs, patients wearing BRs reported that they caused less interference with speech, required less compliance to wear them, and were more comfortable to wear than VFRs. Patients found the BRs harder to keep clean. The trail was not registered. © The Author 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  3. The rapid growth of vertically aligned carbon nanotubes using laser heating.

    PubMed

    Park, J B; Jeong, S H; Jeong, M S; Lim, S C; Lee, I H; Lee, Y H

    2009-05-06

    Growth of densely packed vertically aligned carbon nanotubes (VA-CNTs) using laser-induced chemical vapor deposition with visible laser (lambda = 532 nm) irradiation at room temperature is reported. Using a multiple-catalyst layer (Fe/Al/Cr) on quartz as the substrate and an acetylene-hydrogen mixture as the precursor gas, VA-CNT pillars with 60 microm height and 4 microm diameter were grown at a high rate of around 1 microm s(-1) with good reproducibility. It is demonstrated that the fabrication of uniform pillar arrays of VA-CNTs can be achieved with a single irradiation for each pillar using LCVD with no annealing or preprocessing of the substrate. Here, laser fast heating is considered the primary mechanism facilitating the growth of VA-CNT pillars. Field emission characteristics of an array of VA-CNT pillars were then examined to investigate their potential application in vacuum electronic devices.

  4. Surface supported gold-organic hybrids: on-surface synthesis and surface directed orientation.

    PubMed

    Zhang, Haiming; Franke, Jörn-Holger; Zhong, Dingyong; Li, Yan; Timmer, Alexander; Arado, Oscar Díaz; Mönig, Harry; Wang, Hong; Chi, Lifeng; Wang, Zhaohui; Müllen, Klaus; Fuchs, Harald

    2014-04-09

    The surface-assisted synthesis of gold-organic hybrids on Au (111) and Au (100) surfaces is repotred by thermally initiated dehalogenation of chloro-substituted perylene-3,4,9,10-tetracarboxylic acid bisimides (PBIs). Structures and surface-directed alignment of the Au-PBI chains are investigated by scanning tunnelling microscopy in ultra high vacuum conditions. Using dichloro-PBI as a model system, the mechanism for the formation of Au-PBI dimer is revealed with scanning tunnelling microscopy studies and density functional theory calculations. A PBI radical generated from the homolytic C-Cl bond dissociation can covalently bind a surface gold atom and partially pull it out of the surface to form stable PBI-Au hybrid species, which also gives rise to the surface-directed alignment of the Au-PBI chains on reconstructed Au (100) surfaces. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    As part of the R and D program towards a fourth generation light source, a Self-Amplified Spontaneous Emission (SASE) demonstration is being prepared. The Visible-Infrared SASE Amplifier (VISA) undulator will be installed at Brookhaven National Laboratory by the end of the year. The VISA undulator is an in-vacuum, 4-meter long, 1.8 cm period, pure-permanent magnet device, with a novel, strong focusing, permanent magnet FODO array included within the fixed, 6 mm undulator gap. The undulator is constructed of 99 cm long segments. To attain maximum SASE gain requires establishing overlap of electron and photon beams to within 50 {micro}m rms.more » This imposes challenging tolerances on mechanical fabrication and magnetic field quality, and necessitates use of laser straightness interferometry for calibration and alignment of the magnetic axes of the undulator segments. This paper describes the magnetic centerline determination, and the fiducialization and alignment processes which were performed to meet the tolerance goal.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruland, Robert E.

    As part of the R and D program towards a fourth generation light source, a Self-Amplified Spontaneous Emission (SASE) demonstration is being prepared. The Visible-Infrared SASE Amplifier (VISA) undulator is being installed at Brookhaven National Laboratory. The VISA undulator is an in-vacuum, 4-meter long, 1.8 cm period, pure-permanent magnet device, with a novel, strong focusing, permanent magnet FODO array included within the fixed, 6 mm undulator gap. The undulator is constructed of 99 cm long segments. To attain maximum SASE gain requires establishing overlap of electron and photon beams to within 50 pm rms. This imposes challenging tolerances on mechanicalmore » fabrication and magnetic field quality, and necessitates use of laser straightness interferometry for calibration and alignment of the magnetic axes of the undulator segments. This paper describes the magnetic centerline determination, and the fiducialization and alignment processes, which were performed to meet the tolerance goal.« less

  7. Laser refrigeration, alignment and rotation of levitated Yb3+:YLF nanocrystals

    NASA Astrophysics Data System (ADS)

    Rahman, A. T. M. Anishur; Barker, P. F.

    2017-10-01

    The ability to cool and manipulate levitated nanoparticles in vacuum is a promising tool for exploring macroscopic quantum mechanics1,2, precision measurements of forces3 and non-equilibrium thermodynamics4,5. The extreme isolation afforded by optical levitation offers a low-noise, undamped environment that has been used to measure zeptonewton forces3 and radiation pressure shot noise6, and to demonstrate centre-of-mass motion cooling7,8. Ground-state cooling and the creation of macroscopic quantum superpositions are now within reach, but control of both the centre of mass and internal temperature is required. While cooling the centre-of-mass motion to micro-kelvin temperatures has now been achieved, the internal temperature has remained at or above room temperature. Here, we realize a nanocryostat by refrigerating levitated Yb3+:YLF nanocrystals to 130 K using anti-Stokes fluorescence cooling, while simultaneously using the optical trapping field to align the crystal to maximize cooling.

  8. Effect of Grinding at Modified Atmosphere or Vacuum on Browning, Antioxidant Capacities, and Oxidative Enzyme Activities of Apple.

    PubMed

    Kim, Ah-Na; Lee, Kyo-Yeon; Kim, Hyun-Jin; Chun, Jiyeon; Kerr, William L; Choi, Sung-Gil

    2018-01-01

    This study evaluated the effects of grinding at atmospheric pressure (control), under vacuum (∼2.67 kPa), or with modified atmosphere (N 2 and CO 2 ) on the browning, antioxidant activity, phenolics, and oxidative enzyme activity of apples as a function of time. The control group was affected most, showing distinct browning and losing most of the antioxidant activity and concentrations of the main phenolic compounds. The modified atmosphere groups retained color, antioxidant activity, and phenolic compounds better than the control group. Least changes were obtained with vacuum grinding, particularly in terms of preventing enzymatic browning and oxidation of antioxidants apples. At 12 h after grinding, vacuum-ground apples retained total phenolic contents 5.32, 1.54, and 1.49 times higher than control, nitrogen gas, and carbon dioxide gas-ground samples, respectively. The oxidative enzyme activity, including that of polyphenol oxidase and peroxidase, decreased in the control and modified atmosphere group, but they were maintained in the samples ground under the vacuum. In this study, we found that grinding with modified atmosphere or vacuum conditions could effectively prevent browning as well as loss of phenolic compounds and antioxidant activity of ground apples. These results can help scientists and engineers build better grinding systems for retaining nutrient and quality factors of ground apples. In addition, these results may be useful to other fruit and vegetable industries that wish to retain fresh-like quality and nutritional value during grinding and storage. © 2017 Institute of Food Technologists®.

  9. Drying characteristics of whole Musa AA group ‘Kluai Leb Mu Nang’ using hot air and infrared vacuum

    NASA Astrophysics Data System (ADS)

    Kulketwong, C.; Thungsotanon, D.; Suwanpayak, N.

    2017-06-01

    Dried Musa AA group ‘Kluai Leb Mu Nang’ are the famous processing goods of Chumphon province, the south of Thailand. In this paper, we improved the qualities of whole Musa AA group ‘Kluai leb Mu Nang’ by using the hot air and infrared vacuum (HA and infrared vacuum) drying method which has two stages. The first stage of the method is the hot air (HA) and hot air-infrared (HAI) drying for rapidly reducing the moisture content and the drying times at atmospheric pressure, and the second stage, the moisture content, and color of the samples can be controlled by the HA and infrared vacuum drying. The experiment was evaluated by the terms of firmness, color change, moisture content, vacuum pressure and energy consumption at various temperatures. The results were found that the suitable temperature of the HAI and HA and infrared vacuum drying stages at 70°C and 55°C, respectively, while the suitable vacuum pressure in the second process was -0.4 bar. The samples were dried in a total of 28 hrs using 13.83 MJ/kg of specific energy consumption (stage 1 with 8.8 MJ/kg and stage 2 of 5.03 MJ/kg). The physical characteristics of the 21% (wb) of dried bananas can be measured the color change, L*=38.56, a*=16.47 and b*=16.3, was approximate the goods from the local market, whereas the firmness of them was more tender and shown a value of 849.56 kN/m3.

  10. Comparison of intraocular pressure during the application of a liquid patient interface (FEMTO LDV Z8) for femtosecond laser-assisted cataract surgery using two different vacuum levels.

    PubMed

    Ebner, Martina; Mariacher, Siegfried; Januschowski, Kai; Boden, Katrin; Seuthe, Anna-Maria; Szurman, Peter; Boden, Karl Thomas

    2017-08-01

    To evaluate intraocular pressure (IOP) using the application of a novel liquid patient interface for femtosecond laser-assisted cataract surgery with the FEMTO LDV Z8. IOP was evaluated in enucleated porcine eyes prior, during and after the application of the Femto LDV Z8 liquid patient interface (Ziemer Ophthalmic Systems, Switzerland) using intracameral cannulation (n=20), intravitreal cannulation (n=20), rebound tonometry (n=20) and indentation tonometry (n=20). Pressure was assessed prior vacuum, during vacuum (30 s, 1 min, 2 min, 3 min) and after releasing the vacuum (1 min and 2 min). Two groups with different predefined vacuum levels (350 mbar, 420 mbar) were investigated. Mean intracameral pressure (±SD) increased during vacuum application from 20 mm Hg to 52.00 mm Hg (±6.35mm Hg; p=0.005) and 45.18 mmHg (±4.34 mm Hg; p=0.005) for the 420 mbar and the 350 mbar vacuum levels, respectively. Mean intravitreal pressure increased from 20 mm Hg to 25.60 mm Hg (±9.85 mm Hg; p=0.058) and 28.10 mm Hg (±2.54 mm Hg; p=0.059) for the 420 mbar and the 350 mbar vacuum levels, respectively. Pressure values from indentation and rebound tonometry were in between intracameral and intravitreal values. Mean intracameral IOP was 18.1% higher (p=0.019) in the 420 mbar group compared with the 350 mbar group. During vacuum application of the liquid patient interface of the Femto LDV Z8 for femtosecond laser-assisted cataract surgery, IOP values were higher in the anterior chamber compared with the intravitreal pressure measurements. The higher predefined vacuum level (350 mbar vs 420 mbar) resulted in significant higher intracameral IOP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Development of controlled solid-state alignment for alnico permanent magnets in near-final shape

    DOE PAGES

    Anderson, Iver E.; Kassen, Aaron G.; White, Emma M. H.; ...

    2017-01-09

    The 2011 price shock in the rare earth (RE) permanent magnet (PM) marketplace precipitated realization of extremely poor RE supply diversity and drove renewed research in RE-free permanent magnets such as “alnico.” Essentially, alnico is an Al-Ni-Co-Fe alloy with high magnetic saturation and T C, but low coercivity. It also was last researched extensively in the 1970’s. Currently alnico “9” magnets with the highest energy product (10MGOe) are manufactured by directional solidification to make highly aligned anisotropic magnets. This work developed novel powder processing techniques to improve on unaligned anisotropic alnico “8H” with elevated coercivity. Gas atomization was used tomore » produce pre-alloyed powder for binder-assisted compression molding of near-final shape magnets that were vacuum sintered to full density (<1% porosity). Biased grain growth with resulting grain alignment was achieved during a second solution annealing step, during which a uni-axial stress was applied along the axis parallel to the magnetization direction. Lastly, evaluation of heavily stressed samples (>250g) showed reduced overall loop squareness compared to unaligned (equiaxed) 8H due to grain rotation-induced misalignment, while low stresses improved squareness and greatly improved alignment compared to equiaxed magnets, with squareness approaching 0.30 and remanence ratio as high as 0.79.« less

  12. Emergency radiology: straightening of the cervical spine in MDCT after trauma—a sign of injury or normal variant?

    PubMed Central

    Deak, Zsuszsanna; Krtakovska, Aina; Ruschi, Francesco; Kammer, Nora; Wirth, Stefan; Reiser, Maximilian; Geyer, Lucas

    2016-01-01

    Objective: To evaluate whether straightening of the cervical spine (C-spine) alignment after trauma can be considered a significant multidetector CT (MDCT) finding. Methods: 160 consecutive patients after C-spine trauma admitted to a Level 1 trauma centre received MDCT according to Canadian Cervical Spine Rule and National Emergency X-Radiography Utilization Study indication rule; subgroups with and without cervical collar immobilization (CCI +/−) were compared with a control group (n = 20) of non-traumatized patients. Two independent readers evaluated retrospectively the alignment, determined the absolute rotational angle of the posterior surface of C2 and C7 (ARA C2–7) and grouped the results for lordosis (<−13°), straight (−13 to +6°) and kyphosis (>+6°). Results: In the two CCI−/CCI+ study groups, the straight or kyphotic alignment significantly (p = 0.001) predominated over lordosis. The number of patients with straight C-spine alignment was higher in the CCI+ group (CCI+ 69% vs CCI− 49%, p = 0.05). A comparison of the CCI+ group vs the CCI− group revealed a slightly smaller number of kyphotic (10% vs 18%, p = 0.34) and lordotic (21% vs 33%, p = 0.33) alignments. Statistically, however, the differences were of no significance. The control group revealed no significant differences. Conclusion: Straightening of the C-spine alone is not a definitive sign of injury but is a biomechanical variation due to CCI and neck positioning during MDCT or active patient control. Advances in knowledge: Straightening of the C-spine alignment in MDCT alone is not a definitive sign of injury. Straightening of the C-spine alignment is related to neck positioning and active patient control. CCI has a straightening effect on the cervical alignment. PMID:26764283

  13. Quark Yukawa pattern from spontaneous breaking of flavour SU(3) 3

    NASA Astrophysics Data System (ADS)

    Nardi, Enrico

    2015-10-01

    A SU(3)Q × SU(3)u × SU(3)d invariant scalar potential breaking spontaneously the quark flavour symmetry can explain the Standard Model flavour puzzle. The approximate alignment in flavour space of the vacuum expectation values of the up and down 'Yukawa fields' results as a dynamical effect. The observed quark mixing angles, the weak CP violating phase, and hierarchical quark masses can be all reproduced at the cost of introducing additional (auxiliary) scalar multiplets, but without the need of introducing hierarchical parameters.

  14. Operation of a gated field emitter using an individual carbon nanofiber cathode

    NASA Astrophysics Data System (ADS)

    Guillorn, M. A.; Melechko, A. V.; Merkulov, V. I.; Ellis, E. D.; Britton, C. L.; Simpson, M. L.; Lowndes, D. H.; Baylor, L. R.

    2001-11-01

    We report on the operation of an integrated gated cathode device using a single vertically aligned carbon nanofiber as the field emission element. This device is capable of operation in a moderate vacuum for extended periods of time without experiencing a degradation of performance. Less than 1% of the total emitted current is collected by the gate electrode, indicating that the emitted electron beam is highly collimated. As a consequence, this device is ideal for applications that require well-focused electron emission from a microscale structure.

  15. ION SOURCE UNIT FOR CALUTRON

    DOEpatents

    Sloan, D.H.; Yockey, H.P.; Schmidt, F.H.

    1959-04-14

    An improvement in the mounting arrangement for an ion source within the vacuum tank of a calutron device is reported. The cathode and arc block of the source are independently supported from a stem passing through the tank wall. The arc block may be pivoted and moved longitudinally with respect to the stem to thereby align the arc chamber in the biock with the cathode and magnetic field in the tank. With this arrangement the elements of the ion source are capable of precise adjustment with respect to one another, promoting increased source efficiency.

  16. Electronic Chemical Potentials of Porous Metal–Organic Frameworks

    PubMed Central

    2014-01-01

    The binding energy of an electron in a material is a fundamental characteristic, which determines a wealth of important chemical and physical properties. For metal–organic frameworks this quantity is hitherto unknown. We present a general approach for determining the vacuum level of porous metal–organic frameworks and apply it to obtain the first ionization energy for six prototype materials including zeolitic, covalent, and ionic frameworks. This approach for valence band alignment can explain observations relating to the electrochemical, optical, and electrical properties of porous frameworks. PMID:24447027

  17. A randomized clinical trial comparing mandibular incisor proclination produced by fixed labial appliances and clear aligners.

    PubMed

    Hennessy, Joe; Garvey, Thérèse; Al-Awadhi, Ebrahim A

    2016-09-01

    To compare the mandibular incisor proclination produced by fixed labial appliances and third generation clear aligners. Patients underwent a course of orthodontic treatment using either fixed labial appliances or clear aligners (Invisalign). Mandibular incisor proclination was measured by comparing pretreatment and near-end treatment lateral cephalograms. Eligibility criteria included adult patients with mild mandibular incisor crowding (<4 mm) and Class I skeletal bases (ANB, 1-4°). The main outcome was the cephalometric change in mandibular incisor inclination to the mandibular plane at the end of treatment. Eligible patients picking a sealed opaque envelope, which indicated their group allocation, was used to achieve randomization. Data was analyzed using a Welch two-sample t-test. Forty-four patients (mean age, 26.4 ± 7.7 years) were randomized in a 1:1 ratio to either the fixed labial appliance or the clear aligner group. Baseline characteristics were similar for both groups: Fixed appliance mean crowding was 2.1 ± 1.3 mm vs clear aligner mean crowding, 2.5 ± 1.3 mm; pretreatment mean mandibular incisor inclination for the fixed appliance group was 90.8 ± 5.4° vs 91.6 ± 6.4° for the clear aligner group. Fixed appliances produced 5.3 ± 4.3° of mandibular incisor proclination. Clear aligners proclined the mandibular incisors by 3.4 ± 3.2°. The difference between the two groups was not statistically significant (P > .05). There was no difference in the amount of mandibular incisor proclination produced by clear aligners and fixed labial appliances in mild crowding cases.

  18. High-order harmonic generation from highly excited states in acetylene

    NASA Astrophysics Data System (ADS)

    Mulholland, Peter; Dundas, Daniel

    2018-04-01

    High-order harmonic generation (HHG) from aligned acetylene molecules interacting with mid infra-red (IR), linearly polarized laser pulses is studied theoretically using a mixed quantum-classical approach in which the electrons are described using time-dependent density-functional theory while the ions are treated classically. We find that for molecules aligned perpendicular to the laser polarization axis, HHG arises from the highest-occupied molecular orbital (HOMO), while for molecules aligned along the laser polarization axis, HHG is dominated by the HOMO-1. In the parallel orientation we observe a double plateau with an inner plateau that is produced by ionization from and recombination back to an autoionizing state. Two pieces of evidence support this idea. First, by choosing a suitably tuned vacuum ultraviolet pump pulse that directly excites the autoionizing state we observe a dramatic enhancement of all harmonics in the inner plateau. Second, in certain circumstances, the position of the inner plateau cutoff does not agree with the classical three-step model. We show that this discrepancy can be understood in terms of a minimum in the dipole recombination matrix element from the continuum to the autoionizing state.

  19. Tuning charge carrier transport and optical birefringence in liquid-crystalline thin films: A new design space for organic light-emitting diodes.

    PubMed

    Keum, Chang-Min; Liu, Shiyi; Al-Shadeedi, Akram; Kaphle, Vikash; Callens, Michiel Koen; Han, Lu; Neyts, Kristiaan; Zhao, Hongping; Gather, Malte C; Bunge, Scott D; Twieg, Robert J; Jakli, Antal; Lüssem, Björn

    2018-01-15

    Liquid-crystalline organic semiconductors exhibit unique properties that make them highly interesting for organic optoelectronic applications. Their optical and electrical anisotropies and the possibility to control the alignment of the liquid-crystalline semiconductor allow not only to optimize charge carrier transport, but to tune the optical property of organic thin-film devices as well. In this study, the molecular orientation in a liquid-crystalline semiconductor film is tuned by a novel blading process as well as by different annealing protocols. The altered alignment is verified by cross-polarized optical microscopy and spectroscopic ellipsometry. It is shown that a change in alignment of the liquid-crystalline semiconductor improves charge transport in single charge carrier devices profoundly. Comparing the current-voltage characteristics of single charge carrier devices with simulations shows an excellent agreement and from this an in-depth understanding of single charge carrier transport in two-terminal devices is obtained. Finally, p-i-n type organic light-emitting diodes (OLEDs) compatible with vacuum processing techniques used in state-of-the-art OLEDs are demonstrated employing liquid-crystalline host matrix in the emission layer.

  20. Functionalized vertically aligned ZnO nanorods for application in electrolyte-insulator-semiconductor based pH sensors and label-free immuno-sensors

    NASA Astrophysics Data System (ADS)

    Kumar, Narendra; Senapati, Sujata; Kumar, Satyendra; Kumar, Jitendra; Panda, Siddhartha

    2016-04-01

    Vertically aligned ZnO nanorods were grown on a SiO2/Si surface by optimization of the temperature and atmosphere for annealing of the seed. The seed layer annealed at 500 °C in vacuum provided well separated and uniform seeds which also provided the best condition to get densely packed, uniformly distributed, and vertically aligned nanorods. These nanorods grown on the substrates were used to fabricate electrolyte-insulator-semiconductor (EIS) devices for pH sensing. Etching of ZnO at acidic pH prevents the direct use of nanorods for pH sensing. Therefore, the nanorods functionalised with 3-aminopropyltriethoxysilane (APTES) were utilized for pH sensing and showed the pH sensitivity of 50.1 mV/pH. APTES is also known to be used as a linker to immobilize biomolecules (such as antibodies). The EIS device with APTES functionalized nanorods was used for the label free detection of prostate-specific antigen (PSA). Finally, voltage shifts of 23 mV and 35 mV were observed with PSA concentrations of 1 ng/ml and 100 ng/ml, respectively.

  1. Characteristics of Surface Sterilization using ECR Plasma

    NASA Astrophysics Data System (ADS)

    Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya

    2015-09-01

    Plasma sterilization techniques have superior characteristics such as a short treatment times, non-toxicity and low thermal damages on the sterilized materials. In plasma sterilization, microorganisms can be sterilized by active radicals, energetic charged particles, and vacuum UV radiation. The influence of each factor depends on the plasma operating parameters. Microwave discharges under the electron cyclotron resonance (ECR) condition produce higher electron temperature and density plasma as compared with other plasma generation techniques. In the present study, characteristics of surface sterilization using ECR plasma have been investigated.The experiment was performed in the vacuum chamber which contains a magnet holder. A pair of rectangular Sm-Co permanent magnets is aligned parallel to each other within the magnet holder. The region of the magnetic field for ECR exists near the magnet holder surface. When the microwave is introduced into the vacuum chamber, a ECR plasma is produced around surface of the magnet holder. High energy electrons and oxygen radicals were observed at ECR zone by electric probe method and optical spectroscopic method. Biological indicators (B.I.) having spore of 106 was sterilized in 2min for oxygen discharge. The temperature of the B.I. installation position was about 55°. The sterilization was achieved by the effect of oxygen radicals and high energy electrons.

  2. High-resolution microscope for tip-enhanced optical processes in ultrahigh vacuum

    NASA Astrophysics Data System (ADS)

    Steidtner, Jens; Pettinger, Bruno

    2007-10-01

    An optical microscope based on tip-enhanced optical processes that can be used for studies on adsorbates as well as thin layers and nanostructures is presented. The microscope provides chemical and topographic informations with a resolution of a few nanometers and can be employed in ultrahigh vacuum as well as gas phase. The construction involves a number of improvements compared to conventional instruments. The central idea is to mount, within an UHV system, an optical platform with all necessary optical elements to a rigid frame that also carries the scanning tunneling microscope unit and to integrate a high numerical aperture parabolic mirror between the scanning probe microscope head and the sample. The parabolic mirror serves to focus the incident light and to collect a large fraction of the scattered light. The first experimental results of Raman measurements on silicon samples as well as brilliant cresyl blue layers on single crystalline gold and platinum surfaces in ultrahigh vacuum are presented. For dye adsorbates a Raman enhancement of ˜106 and a net signal gain of up to 4000 was observed. The focus diameter (˜λ/2) was measured by Raman imaging the focal region on a Si surface. The requirements of the parabolic mirror in terms of alignment accuracy were experimentally determined as well.

  3. A new insight into the phase transition in the early Universe with two Higgs doublets

    NASA Astrophysics Data System (ADS)

    Bernon, Jérémy; Bian, Ligong; Jiang, Yun

    2018-05-01

    We study the electroweak phase transition in the alignment limit of the CP-conserving two-Higgs-doublet model (2HDM) of Type I and Type II. The effective potential is evaluated at one-loop, where the thermal potential includes Daisy corrections and is reliably approximated by means of a sum of Bessel functions. Both 1-stage and 2-stage electroweak phase transitions are shown to be possible, depending on the pattern of the vacuum development as the Universe cools down. For the 1-stage case focused on in this paper, we analyze the properties of phase transition and discover that the field value of the electroweak symmetry breaking vacuum at the critical temperature at which the first order phase transition occurs is largely correlated with the vacuum depth of the 1-loop potential at zero temperature. We demonstrate that a strong first order electroweak phase transition (SFOEWPT) in the 2HDM is achievable and establish benchmark scenarios leading to different testable signatures at colliders. In addition, we verify that an enhanced triple Higgs coupling (including loop corrections) is a typical feature of the SFOPT driven by the additional doublet. As a result, SFOEWPT might be able to be probed at the LHC and future lepton colliders through Higgs pair production.

  4. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms

    2018-01-01

    To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p <0.05) and modulation transfer function (MTF) ( p <0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p <0.05). Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.

  5. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking

    PubMed Central

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit MS

    2018-01-01

    Purpose To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was −0.89±0.35 D in group I and −0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. PMID:29731603

  6. [Assessment of vacuum-assisted vaginal delivery in a frank breech presentation].

    PubMed

    Bleu, G; Deruelle, P; Demetz, J; Michel, S; Dufour, P; Depret, S; Subtil, D

    2015-02-01

    After verification of the eligibility criteria and with an obstetrician familiar with the specific maneuvers likely to be needed, vaginal delivery of breech presentations is possible. If problems arise during the active pushing phase of labor, vacuum extraction has been described in the literature for this uncommon condition with limited series. The aim of this study is to assess retrospectively vacuum extraction in frank breech presentation in our center. This retrospective study of trials of vaginal delivery of fetuses in breech presentation at term compares cases according to whether they did or did not use a vacuum extraction. During a two-year period, 83 patients, whom had trials of vaginal delivery in breech presentations, reached the active pushing/bearing down stage after complete cervical dilatation. Vacuum assistance was applied in six of these (7.2 %). The failure rate for vaginal delivery was significantly higher in the group with compared to without vacuum extraction (33.3 % versus 6.5 %, P<0.05). Moreover, the mean pH at birth was significantly lower in the group with vacuum extraction (7.12±0.11 versus 7.20±0.08, P<0.05), and these infants more frequently had deep cutaneous injuries (66.7 % versus 26.0 %, P<0.05). In fetuses in breech presentation, when vaginal delivery failed, it seems to be safer for the fetuses to perform caesarean section rather than attempt vacuum extraction. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. Annihilation of photochemical reactivity of photo-alignment layer.

    PubMed

    Hong, S H; Hwang, Y J; Lee, S G; Shin, D M

    2008-09-01

    The gas-polymer and liquid-polymer interfacial reactions of photosensitive polyimide can annihilate photo-reactive carbon-carbon double bonds, which remain after photo-alignment process. The annihilation processes dramatically affect voltage holding ratio and reorientation of photo-active functional groups. Photochemical dimerizations were identified using UV-visible and FT-IR spectroscopy. Polyimide films containing cinnamate groups were irradiated by linear polarized ultra violet (LPUV) light. Schadt et al. claims that the photo-alignment results from the anisotropy depletion of the cinnamate side chains as a consequence of the (2+2) cycloaddition reactions. The photo-aligned polyimide induces the orientation of nematic liquid crystals perpendicular to the polarization axis. However, the un-reacted photo-sensitive functional groups generate problems such as image sticking and reduced contrast ratio. Voltage holding ratio and photo-fading observed from photo-alignment layer can be dramatically improved by annihilation process of remnant photoreactive groups.

  8. Wide-angle ITER-prototype tangential infrared and visible viewing system for DIII-D.

    PubMed

    Lasnier, C J; Allen, S L; Ellis, R E; Fenstermacher, M E; McLean, A G; Meyer, W H; Morris, K; Seppala, L G; Crabtree, K; Van Zeeland, M A

    2014-11-01

    An imaging system with a wide-angle tangential view of the full poloidal cross-section of the tokamak in simultaneous infrared and visible light has been installed on DIII-D. The optical train includes three polished stainless steel mirrors in vacuum, which view the tokamak through an aperture in the first mirror, similar to the design concept proposed for ITER. A dichroic beam splitter outside the vacuum separates visible and infrared (IR) light. Spatial calibration is accomplished by warping a CAD-rendered image to align with landmarks in a data image. The IR camera provides scrape-off layer heat flux profile deposition features in diverted and inner-wall-limited plasmas, such as heat flux reduction in pumped radiative divertor shots. Demonstration of the system to date includes observation of fast-ion losses to the outer wall during neutral beam injection, and shows reduced peak wall heat loading with disruption mitigation by injection of a massive gas puff.

  9. Methods for batch fabrication of cold cathode vacuum switch tubes

    DOEpatents

    Walker, Charles A [Albuquerque, NM; Trowbridge, Frank R [Albuquerque, NM

    2011-05-10

    Methods are disclosed for batch fabrication of vacuum switch tubes that reduce manufacturing costs and improve tube to tube uniformity. The disclosed methods comprise creating a stacked assembly of layers containing a plurality of adjacently spaced switch tube sub-assemblies aligned and registered through common layers. The layers include trigger electrode layer, cathode layer including a metallic support/contact with graphite cathode inserts, trigger probe sub-assembly layer, ceramic (e.g. tube body) insulator layer, and metallic anode sub-assembly layer. Braze alloy layers are incorporated into the stacked assembly of layers, and can include active metal braze alloys or direct braze alloys, to eliminate costs associated with traditional metallization of the ceramic insulator layers. The entire stacked assembly is then heated to braze/join/bond the stack-up into a cohesive body, after which individual switch tubes are singulated by methods such as sawing. The inventive methods provide for simultaneously fabricating a plurality of devices as opposed to traditional methods that rely on skilled craftsman to essentially hand build individual devices.

  10. Wide-angle ITER-prototype tangential infrared and visible viewing system for DIII-D

    DOE PAGES

    Lasnier, Charles J.; Allen, Steve L.; Ellis, Ronald E.; ...

    2014-08-26

    An imaging system with a wide-angle tangential view of the full poloidal cross-section of the tokamak in simultaneous infrared and visible light has been installed on DIII-D. The optical train includes three polished stainless steel mirrors in vacuum, which view the tokamak through an aperture in the first mirror, similar to the design concept proposed for ITER. A dichroic beam splitter outside the vacuum separates visible and infrared (IR) light. Spatial calibration is accomplished by warping a CAD-rendered image to align with landmarks in a data image. The IR camera provides scrape-off layer heat flux profile deposition features in divertedmore » and inner-wall-limited plasmas, such as heat flux reduction in pumped radiative divertor shots. As a result, demonstration of the system to date includes observation of fast-ion losses to the outer wall during neutral beam injection, and shows reduced peak wall heat loading with disruption mitigation by injection of a massive gas puff.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekşi, K. Y.; Andaç, I. C.; Çıkıntoğlu, S.

    The recently discovered rotationally powered pulsar PSR J1640–4631 is the first to have a braking index measured, with high enough precision, that is greater than 3. An inclined magnetic rotator in vacuum or plasma would be subject not only to spin-down but also to an alignment torque. The vacuum model can address the braking index only for an almost orthogonal rotator, which is incompatible with the single-peaked pulse profile. The magnetic dipole model with the corotating plasma predicts braking indices between 3 and 3.25. We find that the braking index of 3.15 is consistent with two different inclination angles, 18.°5more » ± 3° and 56° ± 4°. The smaller angle is preferred given that the pulse profile has a single peak and the radio output of the source is weak. We infer the change in the inclination angle to be at the rate −0.°23 per century, three times smaller in absolute value than the rate recently observed for the Crab pulsar.« less

  12. Photogrammetric Metrology for the James Webb Space Telescope Integrated Science Instrument Module

    NASA Technical Reports Server (NTRS)

    Nowak, Maria; Crane, Allen; Davila, Pam; Eichhorn, William; Gill, James; Herrera, Acey; Hill, Michael; Hylan, Jason; Jetten, Mark; Marsh, James; hide

    2007-01-01

    The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISM optical metering structure is a roughly 2.2x1.7x2.2m, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISIM structure must meet its requirements at the approximately 40K cryogenic operating temperature. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISIM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified. We report on the planning for and preliminary testing of a cryogenic metrology system for ISIM based on photogrammetry. Photogrammetry is the measurement of the location of custom targets via triangulation using images obtained at a suite of digital camera locations and orientations. We describe metrology system requirements, plans, and ambient photogrammetric measurements of a mock-up of the ISIM structure to design targeting and obtain resolution estimates. We compare these measurements with those taken from a well known ambient metrology system, namely, the Leica laser tracker system. We also describe the data reduction algorithm planned to interpret cryogenic data from the Flight structure. Photogrammetry was selected from an informal trade study of cryogenic metrology systems because its resolution meets sub-allocations to ISIM alignment requirements and it is a non-contact method that can in principle measure six degrees of freedom changes in target location. In addition, photogrammetry targets can be readily related to targets used for ambient surveys of the structure. By thermally isolating the photogrammetry camera during testing, metrology can be performed in situ during thermal cycling. Photogrammetry also has a small but significant cryogenic heritage in astronomical instrumentation metrology. It was used to validate the displacement/deformation predictions of the reflectors and the feed horns during thermal/vacuum testing (90K) for the Microwave Anisotropy Probe (MAP). It also was used during thermal vacuum testing (100K) to verify shape and component alignment at operational temperature of the High Gain Antenna for New Horizons. With tighter alignment requirements and lower operating temperatures than the aforementioned observatories, ISIM presents new challenges in the development of this metrology system.

  13. [Influence of manufacture technique on translucency and color of dental porcelain].

    PubMed

    Xiong, Fang; Chao, Yong-Lie; Zhu, Zhi-Min

    2007-12-01

    To study the influence of manufacture technique on the translucency and color of dental porcelain. Specimens were made of VITA VMK 95 dentin porcelain and enamel porcelain and divided into 3 groups: Sintering times group (1, 2, 4, 6, 8 and 10 times), sintering temperature group (910, 920, 930, 940 and 950 degrees C), sintering vacuum group (95, 65, 35 and 0 kPa). Transmittance, Y, dominant wavelength and saturation were measured by PR-650 spectra scan spectrocolorimeter. Transmittance of dentin porcelain increased after 6 times repeated sintering. Transmittance of enamel porcelain increased first after the second sintering, and then became decreasing when sintering more than 2 times. Transmittance of enamel porcelain deceased when sintering temperature was lower than standard. Decrease of sintering vacuum caused the transmittance of dentin and enamel porcelain decreased. The changing of value was coordinated with transmittance. Dominant wavelength and saturation had negative correlation with sintering times and temperature, and positive correlation with vacuum. Sintering times, temperature and vacuum all had prominent effects on the translucency and color of dental porcelain. Comparing with dentin porcelain, enamel porcelain was more sensitive with the modification of manufacture technique.

  14. R3D Align web server for global nucleotide to nucleotide alignments of RNA 3D structures.

    PubMed

    Rahrig, Ryan R; Petrov, Anton I; Leontis, Neocles B; Zirbel, Craig L

    2013-07-01

    The R3D Align web server provides online access to 'RNA 3D Align' (R3D Align), a method for producing accurate nucleotide-level structural alignments of RNA 3D structures. The web server provides a streamlined and intuitive interface, input data validation and output that is more extensive and easier to read and interpret than related servers. The R3D Align web server offers a unique Gallery of Featured Alignments, providing immediate access to pre-computed alignments of large RNA 3D structures, including all ribosomal RNAs, as well as guidance on effective use of the server and interpretation of the output. By accessing the non-redundant lists of RNA 3D structures provided by the Bowling Green State University RNA group, R3D Align connects users to structure files in the same equivalence class and the best-modeled representative structure from each group. The R3D Align web server is freely accessible at http://rna.bgsu.edu/r3dalign/.

  15. Thermal and Alignment Analysis of the Instrument-Level ATLAS Thermal Vacuum Test

    NASA Technical Reports Server (NTRS)

    Bradshaw, Heather

    2012-01-01

    This paper describes the thermal analysis and test design performed in preparation for the ATLAS thermal vacuum test. NASA's Advanced Topographic Laser Altimeter System (ATLAS) will be flown as the sole instrument aboard the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). It will be used to take measurements of topography and ice thickness for Arctic and Antarctic regions, providing crucial data used to predict future changes in worldwide sea levels. Due to the precise measurements ATLAS is taking, the laser altimeter has very tight pointing requirements. Therefore, the instrument is very sensitive to temperature-induced thermal distortions. For this reason, it is necessary to perform a Structural, Thermal, Optical Performance (STOP) analysis not only for flight, but also to ensure performance requirements can be operationally met during instrument-level thermal vacuum testing. This paper describes the thermal model created for the chamber setup, which was used to generate inputs for the environmental STOP analysis. This paper also presents the results of the STOP analysis, which indicate that the test predictions adequately replicate the thermal distortions predicted for flight. This is a new application of an existing process, as STOP analyses are generally performed to predict flight behavior only. Another novel aspect of this test is that it presents the opportunity to verify pointing results of a STOP model, which is not generally done. It is possible in this case, however, because the actual pointing will be measured using flight hardware during thermal vacuum testing and can be compared to STOP predictions.

  16. Alignment of galaxies relative to their local environment in SDSS-DR8

    NASA Astrophysics Data System (ADS)

    Hirv, A.; Pelt, J.; Saar, E.; Tago, E.; Tamm, A.; Tempel, E.; Einasto, M.

    2017-03-01

    Aims: We study the alignment of galaxies relative to their local environment in SDSS-DR8 and, using these data, we discuss evolution scenarios for different types of galaxies. Methods: We defined a vector field of the direction of anisotropy of the local environment of galaxies. We summed the unit direction vectors of all close neighbours of a given galaxy in a particular way to estimate this field. We found the alignment angles between the spin axes of disc galaxies, or the minor axes of elliptical galaxies, and the direction of anisotropy. The distributions of cosines of these angles are compared to the random distributions to analyse the alignment of galaxies. Results: Sab galaxies show perpendicular alignment relative to the direction of anisotropy in a sparse environment, for single galaxies and galaxies of low luminosity. Most of the parallel alignment of Scd galaxies comes from dense regions, from 2...3 member groups and from galaxies with low luminosity. The perpendicular alignment of S0 galaxies does not depend strongly on environmental density nor luminosity; it is detected for single and 2...3 member group galaxies, and for main galaxies of 4...10 member groups. The perpendicular alignment of elliptical galaxies is clearly detected for single galaxies and for members of ≤10 member groups; the alignment increases with environmental density and luminosity. Conclusions: We confirm the existence of fossil tidally induced alignment of Sab galaxies at low z. The alignment of Scd galaxies can be explained via the infall of matter to filaments. S0 galaxies may have encountered relatively massive mergers along the direction of anisotropy. Major mergers along this direction can explain the alignment of elliptical galaxies. Less massive, but repeated mergers are possibly responsible for the formation of elliptical galaxies in sparser areas and for less luminous elliptical galaxies.

  17. Application of Carbon Based Nano-Materials to Aeronautics and Space Lubrication

    NASA Technical Reports Server (NTRS)

    Street, Kenneth W., Jr.; Miyoshi, Kazuhisa; Wal, Randy L. Vander

    2007-01-01

    The tribology program at NASA Glenn Research Center in Cleveland, Ohio, is investigating carbon based nano-particles for their potential in advanced concept lubrication products. Service conditions range from high temperature atmospheric to low temperature vacuum. Some of the lubricants and surface coatings of tribological significance that we have evaluated include neat nano-particles, both grown in-situ and as bulk material deposited on the substrate, and nano-particles dispersed in oils which are all highly substrate interactive. We discuss results of testing these systems in a spiral orbit tribometer (SOT) and a unidirectional pin-on-disc (PoD) tribometer. A nano-onions/Krytox mixture evaluated as a lubricant for angular contact bearings in air caused a marked lowering of the coefficient of friction (CoF) (0.04 to 0.05) for the mixture with an eight-fold improvement in lifetime over that of the Krytox alone. In vacuum, no effect was observed from the nano-onions. Multi-walled nanotubes (MWNT) and graphitized MWNT were tested under sliding friction in both air and vacuum. The MWNT which were grown in-situ oriented normal to the sliding surface exhibited low CoF (0.04) and long wear lives. Bulk MWNT also generate low CoF (0.01 to 0.04, vacuum; and 0.06, air) and long wear life (>1 million orbits, vacuum; and >3.5 million, air). Dispersed graphitized MWNT were superior to MWNT and both were superior to aligned MWNT indicating that orientation is not an issue for solid lubrication. Single-walled nanotubes (SWNT) were modified by cutting into shorter segments and by fluorination. All SWNTs exhibited low CoF in air, with good wear lives. The SWNT with slight fluorination yielded an ultra-low CoF of 0.002 although the best wear life was attributed to the nascent SWNT.

  18. Alignment and Initial Operation of an Advanced Solar Simulator

    NASA Technical Reports Server (NTRS)

    Jaworske, Donald A.; Jefferies, Kent S.; Mason, Lee S.

    1996-01-01

    A solar simulator utilizing nine 30-kW xenon arc lamps was built to provide radiant power for testing a solar dynamic space power system in a thermal vacuum environment. The advanced solar simulator achieved the following values specific to the solar dynamic system: (1) a subtense angle of 1 deg; (2) the ability to vary solar simulator intensity up to 1.7 kW/sq m; (3) a beam diameter of 4.8 m; and (4) uniformity of illumination on the order of +/-10%. The flexibility of the solar simulator design allows for other potential uses of the facility.

  19. Hydrostatic Level Sensors as High Precision Ground Motion Instrumentation for Tevatron and Other Energy Frontier Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volk, James; Hansen, Sten; Johnson, Todd

    2012-01-01

    Particle accelerators require very tight tolerances on the alignment and stability of their elements: magnets, accelerating cavities, vacuum chambers, etc. In this article we describe the Hydrostatic Level Sensors (HLS) for very low frequency measurements used in a variety of facilities at Fermilab. We present design features of the sensors, outline their technical parameters, describe their test and calibration procedures, discuss different regimes of operation and give few illustrative examples of the experimental data. Detail experimental results of the ground motion measurements with these detectors will be presented in subsequent papers.

  20. The effective chiral Lagrangian from the theta term

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mereghetti, E., E-mail: emanuele@physics.arizona.ed; Hockings, W.H., E-mail: whockings@bmc.ed; Kolck, U. van, E-mail: vankolck@physics.arizona.ed

    2010-11-15

    We construct the effective chiral Lagrangian involving hadronic and electromagnetic interactions originating from the QCD {theta}-bar term. We impose vacuum alignment at both quark and hadronic levels, including field redefinitions to eliminate pion tadpoles. We show that leading time-reversal-violating (TV) hadronic interactions are related to isospin-violating interactions that can in principle be determined from charge-symmetry-breaking experiments. We discuss the complications that arise from TV electromagnetic interactions. Some implications of the expected sizes of various pion-nucleon TV interactions are presented, and the pion-nucleon form factor is used as an example.

  1. Wavefront Tilt And Beam Walk Correction For A Pulsed Laser System

    NASA Astrophysics Data System (ADS)

    Bartosewcz, Mike; Tyburski, Joe

    1986-05-01

    The Lockheed Beam Alignment Assembly (BAA) is designed to be a space qualifiable, long life, low bandwidth beam stabilization system. The BAA will stabilize a wandering pulsed laser beam with an input beam tilt of ±750 microradians and translation of ±2.5 mm by two orders of magnitude at the bandwidth of interest. A bandwidth of three hertz was selected to remove laser and optical train thermal drifts and launch induced strain effects. The lambda over twenty RMS wavefront will be maintained in the optics at full power under vacuum test, to demonstrate space qualifiability and optical performance.

  2. Alpha LAMP Integration Facility

    NASA Technical Reports Server (NTRS)

    Oshiro, Richard; Sowers, Dennis; Gargiulo, Joe; Mcgahey, Mark

    1994-01-01

    This paper describes the activity recently completed to meet the simulated space environment requirements for the ground-based testing of an integrated Space Based Laser (SBL) system experiment. The need to maintain optical alignment in the challenging dynamic environment of the pressure recovery system required to simulate space dominated the design requirements. A robust system design was established which minimized the total program costs, most notably by reducing the cost of integrating the components of the experiment. The components of the experiment are integrated on an optical bench in a clean area adjacent to the vacuum chamber and moved on air bearings into the chamber for testing.

  3. Edge Thomson scattering diagnostic on COMPASS tokamak: Installation, calibration, operation, improvements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bohm, P., E-mail: bohm@ipp.cas.cz; Bilkova, P.; Melich, R.

    2014-11-15

    The core Thomson scattering diagnostic (TS) on the COMPASS tokamak was put in operation and reported earlier. Implementation of edge TS, with spatial resolution along the laser beam up to ∼1/100 of the tokamak minor radius, is presented now. The procedure for spatial calibration and alignment of both core and edge systems is described. Several further upgrades of the TS system, like a triggering unit and piezo motor driven vacuum window shutter, are introduced as well. The edge TS system, together with the core TS, is now in routine operation and provides electron temperature and density profiles.

  4. New PSA high concentration solar furnace SF40

    NASA Astrophysics Data System (ADS)

    Rodriguez, Jose; Cañadas, Inmaculada; Zarza, Eduardo

    2016-05-01

    A new solar furnace has been designed and built at Plataforma Solar de Almería. In this work, its main components such as heliostat, concentrator, attenuator and test table, and the method used to align them are described. Other equipment like the auxiliary systems necessary for the solar operation, vacuum chamber and gas system are outlined too. Finally, the thermal characteristics of the focus were measured during a test campaign, where different planes along the optical axis were scanned with a radiometer, and the peak flux was obtained and is presented in the last section of this report.

  5. Articular chondrocyte alignment in the rat after surgically induced osteoarthritis

    PubMed Central

    Takahashi, Hideaki; Tamaki, Hiroyuki; Yamamoto, Noriaki; Onishi, Hideaki

    2017-01-01

    [Purpose] Chondrocytes in articular cartilage are aligned as columns from the joint surface. Notably, loss of chondrocyte and abnormalities of differentiation factors give rise to osteoarthritis (OA). However, the relationship between chondrocyte alignment and OA progression remains unclear. This study was performed to investigate temporal alterations in surgically-induced OA rats. [Subjects and Methods] Thirteen-week-old Wistar rats (n=30) underwent destabilized medial meniscus surgery in their right knee and sham surgery in their left knee. Specimens (n=5) were collected at 0, 1, 2, 4 and 8 weeks after surgery. Histological analysis with Osteoarthritis Research Society International (OARSI) scores, cell density ratios, cell alignments and correlation between OARSI scores and cell density/alignment was performed. [Results] OARSI scores were significantly higher at 1, 2, 4 and 8 weeks in the DMM group than in the control. Cell density ratios were decreased significantly in the DMM group at 2, 4 and 8 weeks compared with the control. Chondrocyte alignment was decreased significantly in the DMM group at 4 and 8 weeks. There were negative correlations between OA severity and cell density / cell alignment. [Conclusion] The results suggest a relationship between chondrocyte alignment and cartilage homeostasis, which plays an important role in OA progression. PMID:28533592

  6. Photoemission Spectroscopy Studies of Methylammonium Lead Iodide Perovskite Thin Films and Interfaces

    NASA Astrophysics Data System (ADS)

    Thibau, Emmanuel S.

    Organometal halide perovskites have recently emerged as promising materials for fundamentally low-cost, high-performance optoelectronics. In this thesis, we utilize thermal co-evaporation of PbI2 and CH3NH 3 I to fabricate thin films of CH3NH3PbI 3. We first investigate the effect of stoichiometry on some of its structural, optical and electronic properties. Then, we study the energy level alignment of CH3NH3PbI3 with 6 organic semiconductors, revealing good agreement between the data and the theory of vacuum level alignment. Finally, the interface formed between CH3NH 3PbI3 and MoO3 is examined. The findings suggest migration of iodide species into the oxide layer, resulting in deterioration of its chemical and electronic properties. Insertion of an organic interlayer is shown to mitigate these undesirable effects. The results of this work could be of use in device engineering, where knowledge of such interfacial phenomena is of utmost importance in achieving optimized device structures.

  7. Vertically Aligned and Interconnected Boron Nitride Nanosheets for Advanced Flexible Nanocomposite Thermal Interface Materials.

    PubMed

    Chen, Jin; Huang, Xingyi; Sun, Bin; Wang, Yuxin; Zhu, Yingke; Jiang, Pingkai

    2017-09-13

    The continuous evolution toward semiconductor technology in the "more-than-Moore" era and rapidly increasing power density of modern electronic devices call for advanced thermal interface materials (TIMs). Here, we report a novel strategy to construct flexible polymer nanocomposite TIMs for advanced thermal management applications. First, aligned polyvinyl alcohol (PVA) supported and interconnected 2D boron nitride nanosheets (BNNSs) composite fiber membranes were fabricated by electrospinning. Then, the nanocomposite TIMs were constructed by rolling the PVA/BNNS composite fiber membranes to form cylinders and subsequently vacuum-assisted impregnation of polydimethylsiloxane (PDMS) into the porous cylinders. The nanocomposite TIMs not only exhibit a superhigh through-plane thermal conductivity enhancement of about 10 times at a low BNNS loading of 15.6 vol % in comparison with the pristine PDMS but also show excellent electrical insulating property (i.e., high volume electrical resistivity). The outstanding thermal management capability of the nanocomposite TIMs was practically confirmed by capturing the surface temperature variations of a working LED chip integrated with the nanocomposite TIMs.

  8. Enhanced field electron emission from aligned diamond-like carbon nanorod arrays prepared by reactive ion beam etching

    NASA Astrophysics Data System (ADS)

    Zhao, Yong; Qin, Shi-Qiao; Zhang, Xue-Ao; Chang, Sheng-Li; Li, Hui-Hui; Yuan, Ji-Ren

    2016-05-01

    Homogeneous diamond-like carbon (DLC) films were deposited on Si supports by a pulsed filtered cathodic vacuum arc deposition system. Using DLC films masked by Ni nanoparticles as precursors, highly aligned diamond-like carbon nanorod (DLCNR) arrays were fabricated by the etching of inductively coupled radio frequency oxygen plasma. The as-prepared DLCNR arrays exhibit excellent field emission properties with a low turn-on field of 2.005 V μm-1 and a threshold field of 4.312 V μm-1, respectively. Raman spectroscopy and x-ray photoelectron spectroscopy were employed to determine the chemical bonding structural change of DLC films before and after etching. It is confirmed that DLC films have good connection with Si supports via the formation of the SiC phase, and larger conductive sp2 domains are formed in the as-etched DLC films, which play essential roles in the enhanced field emission properties for DLCNR arrays.

  9. Characterization of the room temperature payload prototype for the cryogenic interferometric gravitational wave detector KAGRA.

    PubMed

    Peña Arellano, Fabián Erasmo; Sekiguchi, Takanori; Fujii, Yoshinori; Takahashi, Ryutaro; Barton, Mark; Hirata, Naoatsu; Shoda, Ayaka; van Heijningen, Joris; Flaminio, Raffaele; DeSalvo, Riccardo; Okutumi, Koki; Akutsu, Tomotada; Aso, Yoichi; Ishizaki, Hideharu; Ohishi, Naoko; Yamamoto, Kazuhiro; Uchiyama, Takashi; Miyakawa, Osamu; Kamiizumi, Masahiro; Takamori, Akiteru; Majorana, Ettore; Agatsuma, Kazuhiro; Hennes, Eric; van den Brand, Jo; Bertolini, Alessandro

    2016-03-01

    KAGRA is a cryogenic interferometric gravitational wave detector currently under construction in the Kamioka mine in Japan. Besides the cryogenic test masses, KAGRA will also rely on room temperature optics which will hang at the bottom of vibration isolation chains. The payload of each chain comprises an optic, a system to align it, and an active feedback system to damp the resonant motion of the suspension itself. This article describes the performance of a payload prototype that was assembled and tested in vacuum at the TAMA300 site at the NAOJ in Mitaka, Tokyo. We describe the mechanical components of the payload prototype and their functionality. A description of the active components of the feedback system and their capabilities is also given. The performance of the active system is illustrated by measuring the quality factors of some of the resonances of the suspension. Finally, the alignment capabilities offered by the payload are reported.

  10. ACCELERATORS: Beam based alignment of the SSRF storage ring

    NASA Astrophysics Data System (ADS)

    Zhang, Man-Zhou; Li, Hao-Hu; Jiang, Bo-Cheng; Liu, Gui-Min; Li, De-Ming

    2009-04-01

    There are 140 beam position monitors (BPMs) in the Shanghai Synchrotron Radiation Facility (SSRF) storage ring used for measuring the closed orbit. As the BPM pickup electrodes are assembled directly on the vacuum chamber, it is important to calibrate the electrical center offset of the BPM to an adjacent quadrupole magnetic center. A beam based alignment (BBA) method which varies individual quadrupole magnet strength and observes its effects on the orbit is used to measure the BPM offsets in both the horizontal and vertical planes. It is a completely automated technique with various data processing methods. There are several parameters such as the strength change of the correctors and the quadrupoles which should be chosen carefully in real measurement. After several rounds of BBA measurement and closed orbit correction, these offsets are set to an accuracy better than 10 μm. In this paper we present the method of beam based calibration of BPMs, the experimental results of the SSRF storage ring, and the error analysis.

  11. Explaining compact groups as change alignments

    NASA Technical Reports Server (NTRS)

    Mamon, Gary A.

    1990-01-01

    The physical nature of the apparently densest groups of galaxies, known as compact groups is a topic of some recent controversy, despite the detailed observations of a well-defined catalog of 100 isolated compact groups compiled by Hickson (1982). Whereas many authors have espoused the view that compact groups are bound systems, typically as dense as they appear in projection on the sky (e.g., Williams & Rood 1987; Sulentic 1987; Hickson & Rood 1988), others see them as the result of chance configurations within larger systems, either in 1D (chance alignments: Mamon 1986; Walke & Mamon 1989), or in 3D (transient cores: Rose 1979). As outlined in the companion review to this contribution (Mamon, in these proceedings), the implication of Hickson's compact groups (HCGs) being dense bound systems is that they would then constitute the densest isolated systems of galaxies in the Universe and the privileged site for galaxy interactions. In a previous paper (Mamon 1986), the author reviewed the arguments given for the different theories of compact groups. Since then, a dozen papers have been published on the subject, including a thorough and perceptive review by White (1990), thus more than doubling the amount written on the subject. Here, the author first enumerates the arguments that he brought up in 1986 substantiating the chance alignment hypothesis, then he reviews the current status of the numerous recent arguments arguing against chance alignments and/or for the bound dense group hypothesis (both for the majority of HCGs but not all of them), and finally he reconsiders each one of these anti-chance alignment arguments and shows that, rather than being discredited, the chance alignment hypothesis remains a fully consistent explanation for the nature of compact groups.

  12. Vacuum-Compatible Wideband White Light and Laser Combiner Source System

    NASA Technical Reports Server (NTRS)

    Azizi, Alineza; Ryan, Daniel J.; Tang, Hong; Demers, Richard T.; Kadogawa, Hiroshi; An, Xin; Sun, George Y.

    2010-01-01

    For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

  13. Half versus full vacuum suction drainage after modified radical mastectomy for breast cancer- a prospective randomized clinical trial[ISRCTN24484328

    PubMed Central

    Chintamani; Singhal, Vinay; Singh, JP; Bansal, Anju; Saxena, Sunita

    2005-01-01

    Background Suction drains are routinely used after modified radical mastectomy and are an important factor contributing to increased hospital stay as the patients are often discharged only after their removal. Amongst various factors that influence the amount of postoperative drainage, the negative suction pressure applied to the drain has been reported to be of great significance. While a high negative suction pressure is expected to drain the collection and reduce the dead space promptly, it may also prevent the leaking lymphatics from closing and lead to increased drainage from the wound. Against this background a prospective randomized clinical study was conducted to compare the amount and duration of drainage between a half negative suction and full vacuum suction drainage in patients following modified radical mastectomy. The associated postoperative morbidity was also compared between the two groups. Methods 85 FNAC (fine needle aspiration cytology) proven cases of locally advanced breast cancer were randomized. (Using randomly ordered sealed envelops, which were opened immediately before the closure of the wound) in to 50 patients with full vacuum suction (pressure = 700 g/m2) and 35 cases in to half vacuum suction drainage (pressure = 350 g/m2) groups. The two groups were comparable in respect of age, weight, and technique of operation and extent of axillary dissection. Surgery was performed by the same surgical team comprising of five surgeons (two senior and three resident surgeons) using a standardized technique with electrocautery. External compression dressing was provided over the axilla for first 48 hrs and following that patients were encouraged to do active and passive shoulder exercises. The outcomes measured were postoperative morbidity and the length of hospital stay. Statistical methods used: Descriptive studies were performed with SPSS version 10 and group characteristics were compared using student t-test. Results Half vacuum suction drains were removed earlier than the full suction vacuum suction drains. There was no significant difference in the incidence of seroma formation in the two groups and there was a significant reduction in the total hospital stay in patients with half vacuum suction drainage systems as compared to the full suction drainage group (p < 0.001) without any added morbidity. Conclusions Half negative suction drains provide an effective compromise between no suction and full or high suction drainage after modified radical mastectomy by reducing the hospital stay and the post operative morbidity including post operative seromas. PMID:15676064

  14. AmpliVar: mutation detection in high-throughput sequence from amplicon-based libraries.

    PubMed

    Hsu, Arthur L; Kondrashova, Olga; Lunke, Sebastian; Love, Clare J; Meldrum, Cliff; Marquis-Nicholson, Renate; Corboy, Greg; Pham, Kym; Wakefield, Matthew; Waring, Paul M; Taylor, Graham R

    2015-04-01

    Conventional means of identifying variants in high-throughput sequencing align each read against a reference sequence, and then call variants at each position. Here, we demonstrate an orthogonal means of identifying sequence variation by grouping the reads as amplicons prior to any alignment. We used AmpliVar to make key-value hashes of sequence reads and group reads as individual amplicons using a table of flanking sequences. Low-abundance reads were removed according to a selectable threshold, and reads above this threshold were aligned as groups, rather than as individual reads, permitting the use of sensitive alignment tools. We show that this approach is more sensitive, more specific, and more computationally efficient than comparable methods for the analysis of amplicon-based high-throughput sequencing data. The method can be extended to enable alignment-free confirmation of variants seen in hybridization capture target-enrichment data. © 2015 WILEY PERIODICALS, INC.

  15. Epitaxial pentacene films grown on the surface of ion-beam-processed gate dielectric layer

    NASA Astrophysics Data System (ADS)

    Chou, W. Y.; Kuo, C. W.; Cheng, H. L.; Mai, Y. S.; Tang, F. C.; Lin, S. T.; Yeh, C. Y.; Horng, J. B.; Chia, C. T.; Liao, C. C.; Shu, D. Y.

    2006-06-01

    The following research describes the process of fabrication of pentacene films with submicron thickness, deposited by thermal evaporation in high vacuum. The films were fabricated with the aforementioned conditions and their characteristics were analyzed using x-ray diffraction, scanning electron microscopy, polarized Raman spectroscopy, and photoluminescence. Organic thin-film transistors (OTFTs) were fabricated on an indium tin oxide coated glass substrate, using an active layer of ordered pentacene molecules, which were grown at room temperature. Pentacene film was aligned using the ion-beam aligned method, which is typically employed to align liquid crystals. Electrical measurements taken on a thin-film transistor indicated an increase in the saturation current by a factor of 15. Pentacene-based OTFTs with argon ion-beam-processed gate dielectric layers of silicon dioxide, in which the direction of the ion beam was perpendicular to the current flow, exhibited a mobility that was up to an order of magnitude greater than that of the controlled device without ion-beam process; current on/off ratios of approximately 106 were obtained. Polarized Raman spectroscopy investigation indicated that the surface of the gate dielectric layer, treated with argon ion beam, enhanced the intermolecular coupling of pentacene molecules. The study also proposes the explanation for the mechanism of carrier transportation in pentacene films.

  16. LAMBADA and InflateGRO2: efficient membrane alignment and insertion of membrane proteins for molecular dynamics simulations.

    PubMed

    Schmidt, Thomas H; Kandt, Christian

    2012-10-22

    At the beginning of each molecular dynamics membrane simulation stands the generation of a suitable starting structure which includes the working steps of aligning membrane and protein and seamlessly accommodating the protein in the membrane. Here we introduce two efficient and complementary methods based on pre-equilibrated membrane patches, automating these steps. Using a voxel-based cast of the coarse-grained protein, LAMBADA computes a hydrophilicity profile-derived scoring function based on which the optimal rotation and translation operations are determined to align protein and membrane. Employing an entirely geometrical approach, LAMBADA is independent from any precalculated data and aligns even large membrane proteins within minutes on a regular workstation. LAMBADA is the first tool performing the entire alignment process automatically while providing the user with the explicit 3D coordinates of the aligned protein and membrane. The second tool is an extension of the InflateGRO method addressing the shortcomings of its predecessor in a fully automated workflow. Determining the exact number of overlapping lipids based on the area occupied by the protein and restricting expansion, compression and energy minimization steps to a subset of relevant lipids through automatically calculated and system-optimized operation parameters, InflateGRO2 yields optimal lipid packing and reduces lipid vacuum exposure to a minimum preserving as much of the equilibrated membrane structure as possible. Applicable to atomistic and coarse grain structures in MARTINI format, InflateGRO2 offers high accuracy, fast performance, and increased application flexibility permitting the easy preparation of systems exhibiting heterogeneous lipid composition as well as embedding proteins into multiple membranes. Both tools can be used separately, in combination with other methods, or in tandem permitting a fully automated workflow while retaining a maximum level of usage control and flexibility. To assess the performance of both methods, we carried out test runs using 22 membrane proteins of different size and transmembrane structure.

  17. IFU simulator: a powerful alignment and performance tool for MUSE instrument

    NASA Astrophysics Data System (ADS)

    Laurent, Florence; Boudon, Didier; Daguisé, Eric; Dubois, Jean-Pierre; Jarno, Aurélien; Kosmalski, Johan; Piqueras, Laure; Remillieux, Alban; Renault, Edgard

    2014-07-01

    MUSE (Multi Unit Spectroscopic Explorer) is a second generation Very Large Telescope (VLT) integral field spectrograph (1x1arcmin² Field of View) developed for the European Southern Observatory (ESO), operating in the visible wavelength range (0.465-0.93 μm). A consortium of seven institutes is currently commissioning MUSE in the Very Large Telescope for the Preliminary Acceptance in Chile, scheduled for September, 2014. MUSE is composed of several subsystems which are under the responsibility of each institute. The Fore Optics derotates and anamorphoses the image at the focal plane. A Splitting and Relay Optics feed the 24 identical Integral Field Units (IFU), that are mounted within a large monolithic instrument mechanical structure. Each IFU incorporates an image slicer, a fully refractive spectrograph with VPH-grating and a detector system connected to a global vacuum and cryogenic system. During 2012 and 2013, all MUSE subsystems were integrated, aligned and tested to the P.I. institute at Lyon. After successful PAE in September 2013, MUSE instrument was shipped to the Very Large Telescope in Chile where that was aligned and tested in ESO integration hall at Paranal. After, MUSE was directly transferred in monolithic way without dismounting onto VLT telescope where the first light was overcame. This talk describes the IFU Simulator which is the main alignment and performance tool for MUSE instrument. The IFU Simulator mimics the optomechanical interface between the MUSE pre-optic and the 24 IFUs. The optomechanical design is presented. After, the alignment method of this innovative tool for identifying the pupil and image planes is depicted. At the end, the internal test report is described. The success of the MUSE alignment using the IFU Simulator is demonstrated by the excellent results obtained onto MUSE positioning, image quality and throughput. MUSE commissioning at the VLT is planned for September, 2014.

  18. Process for manufacturing hollow fused-silica insulator cylinder

    DOEpatents

    Sampayan, Stephen E.; Krogh, Michael L.; Davis, Steven C.; Decker, Derek E.; Rosenblum, Ben Z.; Sanders, David M.; Elizondo-Decanini, Juan M.

    2001-01-01

    A method for building hollow insulator cylinders that can have each end closed off with a high voltage electrode to contain a vacuum. A series of fused-silica round flat plates are fabricated with a large central hole and equal inside and outside diameters. The thickness of each is related to the electron orbit diameter of electrons that escape the material surface, loop, and return back. Electrons in such electron orbits can support avalanche mechanisms that result in surface flashover. For example, the thickness of each of the fused-silica round flat plates is about 0.5 millimeter. In general, the thinner the better. Metal, such as gold, is deposited onto each top and bottom surface of the fused-silica round flat plates using chemical vapor deposition (CVD). Eutectic metals can also be used with one alloy constituent on the top and the other on the bottom. The CVD, or a separate diffusion step, can be used to defuse the deposited metal deep into each fused-silica round flat plate. The conductive layer may also be applied by ion implantation or gas diffusion into the surface. The resulting structure may then be fused together into an insulator stack. The coated plates are aligned and then stacked, head-to-toe. Such stack is heated and pressed together enough to cause the metal interfaces to fuse, e.g., by welding, brazing or eutectic bonding. Such fusing is preferably complete enough to maintain a vacuum within the inner core of the assembled structure. A hollow cylinder structure results that can be used as a core liner in a dielectric wall accelerator and as a vacuum envelope for a vacuum tube device where the voltage gradients exceed 150 kV/cm.

  19. [The influence of oxygen partial pressure change and vascularization of rabbit wound through negative pressure wound therapy].

    PubMed

    Yang, Fan; Hu, Duan; Bai, Xiang-jun; Zhang, Kun; Li, Ren-jie; Xue, Chen-chen

    2012-07-01

    To investigate the effect of vacuum sealing drainage (VSD) on variation of oxygen partial pressure (PtO2) and vascularization. The 12 cases of rabbit's wound models were undergoing the VSD (vacuum group, n = 6) or conventional therapy (conventional group, n = 6). Variation of PtO2 was measured by oxygen partial pressure admeasuring apparatus, expression of hypoxia inducible factor 1α (HIF-1α) mRNA was measured by real-time fluorescent quantitative PCR, content of vascular endothelial growth factor (VEGF) was measured by ELISA after tissue homogenate in 7 days. Vascular endothelial cell (VEC) and new blood capillary (NBC) of hematoxylin-eosin slice of tissue were counted by using light microscope. Average value of PtO2 of vacuum group was significant lower than conventional group (t = -99.780 to -5.305, P < 0.01). Expression of HIF-1α (30 minutes, 1, 6, 12 hours were 3.11 ± 0.07, 3.68 ± 0.26, 4.16 ± 0.13 and 3.91 ± 0.26 respectively) and content of VEGF (30 minutes, 1, 6, 12 hours were 103.3 ± 2.4, 134.2 ± 9.0, 167.8 ± 3.8 and 232.1 ± 9.5 respectively) of vacuum group were increased after 30 minutes and significant lower than conventional group (t = 13.038 - 80.208, P < 0.01), and both of them were reduced after 24 hours (P < 0.05). Counting numbers of VEC (2.47 ± 0.45 to 4.70 ± 0.38) and NBC (1.33 ± 0.49 to 4.33 ± 0.68) of vacuum group were increased at the same time-point and significant higher than conventional group (t = -0.670 to 16.500, P < 0.05). PtO2 of wound surface could be reduced significantly by VSD. Expression of HIF-1α and content of VEGF were increased by VSD for enhancing differentiated state of VEC and construction of NBC, which were better for vascularization and wound healing.

  20. Comparative evaluation of salivary bisphenol A levels in patients wearing vacuum-formed and Hawley retainers: An in-vivo study.

    PubMed

    Raghavan, Akila Srinivasan; Pottipalli Sathyanarayana, Haritha; Kailasam, Vignesh; Padmanabhan, Sridevi

    2017-03-01

    The aims of the study were to evaluate and compare the bisphenol A (BPA) levels in saliva in patients using vacuum-formed retainers or Hawley retainers. Forty-five patients who had completed their fixed orthodontic treatment and were entering the retention phase were randomly allocated into 1 of 3 groups: vacuum-formed retainer, Hawley retainer fabricated by heat cure, and Hawley retainer fabricated by chemical cure. Saliva samples were collected immediately before placement, within 1 hour after placement, 1 week and 1 month after placement. Statistical analyses were performed by using 2-way analysis of variance and post-hoc multiple-comparisons Tukey HSD tests. Statistically significant BPA levels in saliva were found for all groups (P ≤0.05). The highest levels were noted in the vacuum-formed retainer group, followed by Hawley retainers fabricated by chemical cure; the lowest levels were found with Hawley retainers fabricated by heat cure. With many options available for removable retainers, clinicians should consider the BPA release from these retainers; a Hawley retainer fabricated by heat cure is a favorable choice. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  1. Biclustering as a method for RNA local multiple sequence alignment.

    PubMed

    Wang, Shu; Gutell, Robin R; Miranker, Daniel P

    2007-12-15

    Biclustering is a clustering method that simultaneously clusters both the domain and range of a relation. A challenge in multiple sequence alignment (MSA) is that the alignment of sequences is often intended to reveal groups of conserved functional subsequences. Simultaneously, the grouping of the sequences can impact the alignment; precisely the kind of dual situation biclustering is intended to address. We define a representation of the MSA problem enabling the application of biclustering algorithms. We develop a computer program for local MSA, BlockMSA, that combines biclustering with divide-and-conquer. BlockMSA simultaneously finds groups of similar sequences and locally aligns subsequences within them. Further alignment is accomplished by dividing both the set of sequences and their contents. The net result is both a multiple sequence alignment and a hierarchical clustering of the sequences. BlockMSA was tested on the subsets of the BRAliBase 2.1 benchmark suite that display high variability and on an extension to that suite to larger problem sizes. Also, alignments were evaluated of two large datasets of current biological interest, T box sequences and Group IC1 Introns. The results were compared with alignments computed by ClustalW, MAFFT, MUCLE and PROBCONS alignment programs using Sum of Pairs (SPS) and Consensus Count. Results for the benchmark suite are sensitive to problem size. On problems of 15 or greater sequences, BlockMSA is consistently the best. On none of the problems in the test suite are there appreciable differences in scores among BlockMSA, MAFFT and PROBCONS. On the T box sequences, BlockMSA does the most faithful job of reproducing known annotations. MAFFT and PROBCONS do not. On the Intron sequences, BlockMSA, MAFFT and MUSCLE are comparable at identifying conserved regions. BlockMSA is implemented in Java. Source code and supplementary datasets are available at http://aug.csres.utexas.edu/msa/

  2. The Schwinger Model on S 1: Hamiltonian Formulation, Vacuum and Anomaly

    NASA Astrophysics Data System (ADS)

    Stuart, David

    2014-12-01

    We present a Hamiltonian formulation of the Schwinger model with spatial domain taken to be the circle. It is shown that, in Coulomb gauge, the Hamiltonian is a semi-bounded, self-adjoint operator which is invariant under the group of large gauge transformations. There is a nontrivial action of on fermionic Fock space and its vacuum. This action plays a role analogous to that played by the spectral flow in the infinite Dirac sea formalism. The formulation allows (1) a description of the anomaly and its relation to the group action, and (2) an explicit identification of the vacuum. The anomaly in the chiral conservation law appears as a consequence of insisting upon semi-boundedness and gauge invariance of the quantized Hamiltonian.

  3. Occiput posterior fetal head position increases the risk of anal sphincter injury in vacuum-assisted deliveries.

    PubMed

    Wu, Jennifer M; Williams, Kathryn S; Hundley, Andrew F; Connolly, AnnaMarie; Visco, Anthony G

    2005-08-01

    The purpose of this study was to determine whether an occiput posterior (OP) fetal head position increases the risk for anal sphincter injury when compared with an occiput anterior (OA) position in vacuum-assisted deliveries. We conducted a retrospective cohort study of 393 vacuum-assisted singleton vaginal deliveries. Maternal demographics and obstetric and neonatal data were collected from an obstetric database and chart review. Within the OP group, 41.7% developed a third- or fourth-degree laceration compared with 22.0% in the OA group (OR 2.5, 95% CI 1.4-4.7). In a logistic regression model that controlled for BMI, race, nulliparity, length of second stage, episiotomy, birth weight, head circumference, and fetal head position, OP position was 4.0 times (95% CI 1.7-9.6) more likely to be associated with an anal sphincter injury than OA position. Among vacuum deliveries, an OP head position confers an incrementally increased risk for anal sphincter injury over an OA position.

  4. James Webb Space Telescope in NASA's giant thermal vacuum chamber

    NASA Image and Video Library

    2015-04-20

    Inside NASA's giant thermal vacuum chamber, called Chamber A, at NASA's Johnson Space Center in Houston, the James Webb Space Telescope's Pathfinder backplane test model, is being prepared for its cryogenic test. Previously used for manned spaceflight missions, this historic chamber is now filled with engineers and technicians preparing for a crucial test. Exelis developed and installed the optical test equipment in the chamber. "The optical test equipment was developed and installed in the chamber by Exelis," said Thomas Scorse, Exelis JWST Program Manager. "The Pathfinder telescope gives us our first opportunity for an end-to-end checkout of our equipment." "This will be the first time on the program that we will be aligning two primary mirror segments together," said Lee Feinberg, NASA Optical Telescope Element Manager. "In the past, we have always tested one mirror at a time but this time we will use a single test system and align both mirrors to it as though they are a single monolithic mirror." The James Webb Space Telescope is the scientific successor to NASA's Hubble Space Telescope. It will be the most powerful space telescope ever built. Webb is an international project led by NASA with its partners, the European Space Agency and the Canadian Space Agency. Image credit: NASA/Chris Gunn Text credit: Laura Betz, NASA's Goddard Space Flight Center, Greenbelt, Maryland NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  5. Design, assembly, and testing of a high-resolution relay lens used for holography with operation at both doubled and tripled Nd:YAG laser wavelengths

    NASA Astrophysics Data System (ADS)

    Malone, Robert M.; Capelle, Gene A.; Cox, Brian C.; Frogget, Brent C.; Grover, Mike; Kaufman, Morris I.; Pazuchanics, Peter; Sorenson, Danny S.; Stevens, Gerald D.; Tibbitts, Aric; Turley, William D.

    2009-08-01

    The design and assembly of a nine-element lens that achieves >2000 lp/mm resolution at a 355-nm wavelength (ultraviolet) has been completed. By adding a doublet to this lens system, operation at a 532-nm wavelength (green) with >1100 lp/mm resolution is achieved. This lens is used with high-power laser light to record holograms of fast-moving ejecta particles from a shocked metal surface located inside a test package. Part of the lens and the entire test package are under vacuum with a 1-cm air gap separation. Holograms have been recorded with both doubled and tripled Nd:YAG laser light. The UV operation is very sensitive to the package window's tilt. If this window is tilted by more than 0.1 degrees, the green operation performs with better resolution than that of the UV operation. The setup and alignment are performed with green light, but the dynamic recording can be done with either UV light or green light. A resolution plate can be temporarily placed inside the test package so that a television microscope located beyond the hologram position can archive images of resolution patterns that prove that the calibration wires, interference filter, holographic plate, and relay lenses are in their correct positions. Part of this lens is under vacuum, at the point where the laser illumination passes through a focus. Alignment and tolerancing of this high-resolution lens are presented. Resolution variation across the 12-mm field of view and throughout the 5-mm depth of field is discussed for both wavelengths.

  6. MUSE alignment onto VLT

    NASA Astrophysics Data System (ADS)

    Laurent, Florence; Renault, Edgard; Boudon, Didier; Caillier, Patrick; Daguisé, Eric; Dupuy, Christophe; Jarno, Aurélien; Lizon, Jean-Louis; Migniau, Jean-Emmanuel; Nicklas, Harald; Piqueras, Laure

    2014-07-01

    MUSE (Multi Unit Spectroscopic Explorer) is a second generation Very Large Telescope (VLT) integral field spectrograph developed for the European Southern Observatory (ESO). It combines a 1' x 1' field of view sampled at 0.2 arcsec for its Wide Field Mode (WFM) and a 7.5"x7.5" field of view for its Narrow Field Mode (NFM). Both modes will operate with the improved spatial resolution provided by GALACSI (Ground Atmospheric Layer Adaptive Optics for Spectroscopic Imaging), that will use the VLT deformable secondary mirror and 4 Laser Guide Stars (LGS) foreseen in 2015. MUSE operates in the visible wavelength range (0.465-0.93 μm). A consortium of seven institutes is currently commissioning MUSE in the Very Large Telescope for the Preliminary Acceptance in Chile, scheduled for September, 2014. MUSE is composed of several subsystems which are under the responsibility of each institute. The Fore Optics derotates and anamorphoses the image at the focal plane. A Splitting and Relay Optics feed the 24 identical Integral Field Units (IFU), that are mounted within a large monolithic structure. Each IFU incorporates an image slicer, a fully refractive spectrograph with VPH-grating and a detector system connected to a global vacuum and cryogenic system. During 2012 and 2013, all MUSE subsystems were integrated, aligned and tested to the P.I. institute at Lyon. After successful PAE in September 2013, MUSE instrument was shipped to the Very Large Telescope in Chile where that was aligned and tested in ESO integration hall at Paranal. After, MUSE was directly transported, fully aligned and without any optomechanical dismounting, onto VLT telescope where the first light was overcame the 7th of February, 2014. This paper describes the alignment procedure of the whole MUSE instrument with respect to the Very Large Telescope (VLT). It describes how 6 tons could be move with accuracy better than 0.025mm and less than 0.25 arcmin in order to reach alignment requirements. The success of the MUSE alignment is demonstrated by the excellent results obtained onto MUSE image quality and throughput directly onto the sky.

  7. Robust group-wise rigid registration of point sets using t-mixture model

    NASA Astrophysics Data System (ADS)

    Ravikumar, Nishant; Gooya, Ali; Frangi, Alejandro F.; Taylor, Zeike A.

    2016-03-01

    A probabilistic framework for robust, group-wise rigid alignment of point-sets using a mixture of Students t-distribution especially when the point sets are of varying lengths, are corrupted by an unknown degree of outliers or in the presence of missing data. Medical images (in particular magnetic resonance (MR) images), their segmentations and consequently point-sets generated from these are highly susceptible to corruption by outliers. This poses a problem for robust correspondence estimation and accurate alignment of shapes, necessary for training statistical shape models (SSMs). To address these issues, this study proposes to use a t-mixture model (TMM), to approximate the underlying joint probability density of a group of similar shapes and align them to a common reference frame. The heavy-tailed nature of t-distributions provides a more robust registration framework in comparison to state of the art algorithms. Significant reduction in alignment errors is achieved in the presence of outliers, using the proposed TMM-based group-wise rigid registration method, in comparison to its Gaussian mixture model (GMM) counterparts. The proposed TMM-framework is compared with a group-wise variant of the well-known Coherent Point Drift (CPD) algorithm and two other group-wise methods using GMMs, using both synthetic and real data sets. Rigid alignment errors for groups of shapes are quantified using the Hausdorff distance (HD) and quadratic surface distance (QSD) metrics.

  8. Kinematically aligned TKA can align knee joint line to horizontal.

    PubMed

    Ji, Hyung-Min; Han, Jun; Jin, Dong San; Seo, Hyunseok; Won, Ye-Yeon

    2016-08-01

    The joint line of the native knee is horizontal to the floor and perpendicular to the vertical weight-bearing axis of the patient in a bipedal stance. The purposes of this study were as follows: (1) to find out the distribution of the native joint line in a population of normal patients with normal knees; (2) to compare the native joint line orientation between patients receiving conventional mechanically aligned total knee arthroplasty (TKA), navigated mechanically aligned TKA, and kinematically aligned TKA; and (3) to determine which of the three TKA methods aligns the postoperative knee joint perpendicular to the weight-bearing axis of the limb in bipedal stance. To determine the joint line orientation of a native knee, 50 full-length standing hip-to-ankle digital radiographs were obtained in 50 young, healthy individuals. The angle between knee joint line and the line parallel to the floor was measured and defined as joint line orientation angle (JLOA). JLOA was also measured prior to and after conventional mechanically aligned TKA (65 knees), mechanically aligned TKA using imageless navigation (65 knees), and kinematically aligned TKA (65 knees). The proportion of the knees similar to the native joint line was calculated for each group. The mean JLOA in healthy individuals was parallel to the floor (0.2° ± 1.1°). The pre-operative JLOA of all treatment groups slanted down to the lateral side. Postoperative JLOA slanted down to the lateral side in conventional mechanically aligned TKA (-3.3° ± 2.2°) and in navigation mechanically aligned TKA (-2.6° ± 1.8°), while it was horizontal to the floor in kinematically aligned TKA (0.6° ± 1.7°). Only 6.9 % of the conventional mechanically aligned TKA and 16.9 % of the navigation mechanically aligned TKA were within one SD of the mean JLOA of the native knee, while the proportion was significantly higher (50.8 %) in kinematically aligned TKA. The portion was statistically greater in mechanically aligned TKA group than the other two. Postoperative joint line orientation after kinematically aligned TKA was more similar to that of native knees than that of mechanically aligned TKA and horizontal to the floor. Kinematically aligned TKA can restore pre-arthritic knee joint line orientation, while mechanically aligned TKA is inefficient in achieving the purpose even if navigation TKA is employed. III.

  9. Effect of modified atmosphere and vacuum packaging on TVB-N production of rainbow trout (Oncorhynchus mykiss) and carp (Cyprinus carpio) cuts

    NASA Astrophysics Data System (ADS)

    Babić Milijašević, J.; Milijašević, M.; Đinović-Stojanović, J.; Vranić, D.

    2017-09-01

    The aim of our research was to examine the influence of packaging in modified atmosphere and vacuum on the total volatile basic nitrogen (TVB-N) content in muscle of rainbow trout (Oncorhynchus mykiss) and common carp (Cyprinus carpio), as well as to determine the most suitable gas mixtures for packing of these freshwater species. Three sample groups of trout and carp cuts were investigated. The two groups were packaged in modified atmosphere with different gas ratios: 90%CO2+10%N2 (MAP 1) and 60%CO2+40%N2 (MAP 2), whereas the third group of fish cuts were vacuum packaged. During trials, the trout and carp cuts were stored in refrigerator at 3°C±0.5°C. Determination of TVB-N was performed on 1, 4, 7, 9, 12 and 14 days of storage. The obtained results indicate that the investigated mixtures of gases and vacuum had a significant influence on the values of TVB-N in trout and carp cuts. The lowest increase in TVB-N was established in trout and carp cuts packaged in MAP 1, whereas the highest increase was established in vacuum packaged cuts. Based on the obtained results, it can be concluded that the gas mixture consisting of 90% CO2 and 10% N2 was the most suitable for packaging of fresh trout and carp cuts in terms of TVB-N value.

  10. Method and apparatus for performing in-situ vacuum-assisted metal to glass sealing

    DOEpatents

    Kramer, D.P.; Massey, R.T.

    1985-07-18

    A method and apparatus for assembling and fusing glass to metal in a glass-metal electrical component is disclosed. The component includes a metallic shell formed with upper and lower cylindrical recesses connected together by longitudinal passages, a pair of metal rings and plural metal pins assembled to define electrical feed-throughs. The component parts are assembled on a fixture having a sleeve-like projection and a central mounting projection establishing concentric nesting surfaces to which the metal rings are slip-fitted in concentric alignment with each other spaced from sidewalls of the lower recess. The pins are in electrical contact with the metal rings. A glass pre-form is seated within the upper recess. The assembled structure is heated to a temperature sufficient to melt the glass pre-form which flows under gravity through the passages into the lower recess to provide an insulative seal between the metal parts. The gravity flow of glass is assisted by applying vacuum to the lower recess, ensuring that all spaces between the metal parts are filled with sealing glass without formation of bubbles.

  11. Method and apparatus for performing in-situ vacuum-assisted metal to glass sealing

    DOEpatents

    Kramer, Daniel P.; Massey, Richard T.

    1986-01-01

    A method and apparatus for assembling and fusing glass to metal in a glass-metal electrical component is disclosed. The component includes a metallic shell formed with upper and lower cylindrical recesses connected together by longitudinal passages, a pair of metal rings and plural metal pins assembled to define electrical feed-throughs. The component parts are assembled on a fixture having a sleeve-like projection and a central mounting projection establishing concentric nesting surfaces to which the metal rings are slip-fitted in concentric alignment with each other spaced from sidewalls of the lower recess. The pins are in electrical contact with the metal rings. A glass pre-form is seated within the upper recess. The assembled structure is heated to a temperature sufficient to melt the glass pre-form which flows under gravity through the passages into the lower recess to provide an insulative seal between the metal parts. The gravity flow of glass is assisted by applying vacuum to the lower recess, ensuring that all spaces between the metal parts are filled with sealing glass without formation of bubbles.

  12. One-reactor plasma assisted fabrication of ZnO@TiO 2 multishell nanotubes: assessing the impact of a full coverage on the photovoltaic performance.

    PubMed

    Filippin, Alejandro Nicolas; Macias-Montero, Manuel; Saghi, Zineb; Idígoras, Jesús; Burdet, Pierre; Sanchez-Valencia, Juan R; Barranco, Angel; Migdley, Paul A; Anta, Juan A; Borras, Ana

    2017-08-29

    This paper addresses the fabrication of vertically aligned ZnO@TiO 2 multishell nanotubes by a combined full vacuum-plasma approach at mild temperatures. The growth is carried out within the premises of a one-reactor approach, i.e. minimizing the number of vacuum chambers and sample transferences. In this way, the interface between ZnO and TiO 2 is fully preserved from humidity thus increasing ZnO durability and stability. These nanostructures are studied by scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM) and energy dispersive X-ray spectroscopy in STEM (EDX-STEM). High density one-dimensional arrays of these nanotubes formed on FTO substrates are applied as photoanode in a dye-sensitized solar cell (DSC). The evolution of the dye adsorption capacity and solar cells parameters are explored as a function of the crystallinity and thickness of the TiO 2 shell. The results show the critical effect of a full coverage by TiO 2 of ZnO core to explain the mixed results found in the literature.

  13. Mechanical Design of the LHC Standard Half-Cell

    NASA Astrophysics Data System (ADS)

    Poncet, A.; Brunet, J. C.; Cruikshank, P.; Genet, M.; Parma, V.; Rohmig, P.; Saban, R.; Tavian, L.; Veness, R.; Vlogaert, J.; Williams, L. R.

    1997-05-01

    The LHC Conceptual Design Report issued on 20th October 1995 (CERN/AC/95-05 (LHC) - nicknamed "Yellow Book") introduced significant changes to some fundamental features of the LHC standard half-cell, composed of one quadrupole, 3 dipoles and a set of corrector magnets. A separate cryogenic distribution line was introduced, which was previously inside the main cryostat. The dipole length has been increased from 10 to 15 m and independent powering of the focusing and defocusing quadrupole magnets was chosen. Individual quench protection diodes were introduced in magnets interconnects and many auxiliary bus bars were added to feed in series the various families of correcting superconducting magnets. The various highly intricate basic systems such as: cryostats and cryogenics feeders, superconducting magnets and their electrical feeding and protection, vacuum beam screen and its cooling, support and alignment devices have been redesigned, taking into account the very tight space available. These space constraints are given by the necessity to have maximum integral bending field strength for maximum LHC energy, and the existing LHC tunnel. Finally, cryogenic and vacuum sectorisation have been introduced to reduce downtimes and facilitate commissioning.

  14. Long-distance delivery of multi-channel polarization signals in nuclear fusion research

    NASA Astrophysics Data System (ADS)

    Ko, Jinseok; Chung, Jinil; Lee, Kyuhang

    2017-04-01

    A polarization-preserving optical system that includes a dual photoelastic modulator (PEM) has been designed and fabricated for the motional Stark effect (MSE) diagnostic system which measures internal magnetic field structures inside the tokamak for the Korea Superconducting Tokamak Advanced Research. The collection optics located outside the vacuum window is composed of four lenses, a dielectric coated mirror, and a dichroic beam splitter in addition to the PEM and a polarizer. The fiber dissector is designed based on the focal plane that aligns 25 lines of sight, each of which constitutes a bundle of 19 600-μm fibers. The fibers run about 40 m from the front optics in the tokamak vacuum vessel to the detector in the diagnostic area remote from the tokamak hall. This takes the advantage of the fact that the polarization information is intensity-modulated once going through the PEM and the polarizer. The polarization signals measured by the MSE diagnostic successfully demonstrates its proof-of-principle physics that is critical in the stable and steady-state operation of the tokamak plasmas.

  15. Markov Property of the Conformal Field Theory Vacuum and the a Theorem.

    PubMed

    Casini, Horacio; Testé, Eduardo; Torroba, Gonzalo

    2017-06-30

    We use strong subadditivity of entanglement entropy, Lorentz invariance, and the Markov property of the vacuum state of a conformal field theory to give new proof of the irreversibility of the renormalization group in d=4 space-time dimensions-the a theorem. This extends the proofs of the c and F theorems in dimensions d=2 and d=3 based on vacuum entanglement entropy, and gives a unified picture of all known irreversibility theorems in relativistic quantum field theory.

  16. Comparison of Lumbosacral Alignment in Geriatric and Non-Geriatric patients suffering low back pain.

    PubMed

    Kocyigit, Burhan Fatih; Berk, Ejder

    2018-01-01

    Lumbosacral alignment is a crucial factor for an appropriate spinal function. Changes in spinal alignment lead to diminished body biomechanics. Additionally, lumbosacral alignment may affect quality of life, sagittal balance and fall risk in elderly. In this study, we aimed to compare lumbosacral alignment in geriatric and non-geriatric patients suffering from low back pain. A total of 202 (120 male and 82 female) patients who visited to physical medicine and rehabilitation clinic with low back pain between January 2017 and August 2017 were enrolled in this study. Standing lateral lumbar radiographs were obtained from the electronic hospital database. Lumbar lordosis angle, sacral tilt, lumbosacral angle and lumbosacral disc angle were calculated on lateral standing lumbar radiographs. The mean age of the non-geriatric group was 43.02 ± 13.20 years, the geriatric group was 71.61 ± 6.42 years. In geriatric patients, lumbar lordosis angle, sacral tilt and lumbosacral disc angle were significantly smaller (p = 0.042, p = 0.017 and p = 0.017). No significant differences were observed in lumbosacral angle between the groups (p = 0.508). Our study indicates the specific changes in lumbosacral alignment with aging. Identifying these changes in lumbosacral alignment in the geriatric population will enable to create proper rehabilitation strategies.

  17. ELECTRODYNAMICS OF AXISYMMETRIC PULSAR MAGNETOSPHERE WITH ELECTRON-POSITRON DISCHARGE: A NUMERICAL EXPERIMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Alexander Y.; Beloborodov, Andrei M., E-mail: amb@phys.columbia.edu

    2014-11-01

    We present the first self-consistent global simulations of pulsar magnetospheres with operating e {sup ±} discharge. We focus on the simple configuration of an aligned or anti-aligned rotator. The star is spun up from a zero (vacuum) state to a high angular velocity, and we follow the coupled evolution of its external electromagnetic field and plasma particles using the ''particle-in-cell'' method. A plasma magnetosphere begins to form through the extraction of particles from the star; these particles are accelerated by the rotation-induced electric field, producing curvature radiation and igniting e {sup ±} discharge. We follow the system evolution for severalmore » revolution periods, longer than required to reach a quasi-steady state. Our numerical experiment puts to test previous ideas for the plasma flow and gaps in the pulsar magnetosphere. We first consider rotators capable of producing pairs out to the light cylinder through photon-photon collisions. We find that their magnetospheres are similar to the previously obtained force-free solutions with a Y-shaped current sheet. The magnetosphere continually ejects e {sup ±} pairs and ions. Pair creation is sustained by a strong electric field along the current sheet. We observe powerful curvature and synchrotron emission from the current sheet, consistent with Fermi observations of gamma-ray pulsars. We then study pulsars that can only create pairs in the strong-field region near the neutron star, well inside the light cylinder. We find that both aligned and anti-aligned rotators relax to the ''dead'' state with suppressed pair creation and electric currents, regardless of the discharge voltage.« less

  18. Changes in Rod and Frame Test Scores Recorded in Schoolchildren during Development – A Longitudinal Study

    PubMed Central

    Bagust, Jeff; Docherty, Sharon; Haynes, Wayne; Telford, Richard; Isableu, Brice

    2013-01-01

    The Rod and Frame Test has been used to assess the degree to which subjects rely on the visual frame of reference to perceive vertical (visual field dependence- independence perceptual style). Early investigations found children exhibited a wide range of alignment errors, which reduced as they matured. These studies used a mechanical Rod and Frame system, and presented only mean values of grouped data. The current study also considered changes in individual performance. Changes in rod alignment accuracy in 419 school children were measured using a computer-based Rod and Frame test. Each child was tested at school Grade 2 and retested in Grades 4 and 6. The results confirmed that children displayed a wide range of alignment errors, which decreased with age but did not reach the expected adult values. Although most children showed a decrease in frame dependency over the 4 years of the study, almost 20% had increased alignment errors suggesting that they were becoming more frame-dependent. Plots of individual variation (SD) against mean error allowed the sample to be divided into 4 groups; the majority with small errors and SDs; a group with small SDs, but alignments clustering around the frame angle of 18°; a group showing large errors in the opposite direction to the frame tilt; and a small number with large SDs whose alignment appeared to be random. The errors in the last 3 groups could largely be explained by alignment of the rod to different aspects of the frame. At corresponding ages females exhibited larger alignment errors than males although this did not reach statistical significance. This study confirms that children rely more heavily on the visual frame of reference for processing spatial orientation cues. Most become less frame-dependent as they mature, but there are considerable individual differences. PMID:23724139

  19. Spontaneous lexical alignment in children with an autistic spectrum disorder and their typically developing peers.

    PubMed

    Branigan, Holly P; Tosi, Alessia; Gillespie-Smith, Karri

    2016-11-01

    It is well established that adults converge on common referring expressions in dialogue, and that such lexical alignment is important for successful and rewarding communication. The authors show that children with an autistic spectrum disorder (ASD) and chronological- and verbal-age-matched typically developing (TD) children also show spontaneous lexical alignment. In a card game, both groups tended to refer to an object using the same name as their partner had previously used for the same or a different token of the object. This tendency to align on a pragmatically conditioned aspect of language did not differ between ASD and TD groups, and was unaffected by verbal/chronological age, or (in the ASD group) Theory of Mind or social functioning. The authors suggest that lexical priming can lead to automatic lexical alignment in both ASD and TD children's dialogue. Their results further suggest that ASD children's conversational impairments do not involve an all-encompassing deficit in linguistic imitation. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  20. 46 CFR 154.1335 - Pressure and vacuum protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... audible and visual alarm at the cargo control station, and a remote group alarm in the wheelhouse. (c) If... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and...) Has remote readouts at the cargo control station. (2) If vacuum protection is required under § 154.804...

  1. 46 CFR 154.1335 - Pressure and vacuum protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... audible and visual alarm at the cargo control station, and a remote group alarm in the wheelhouse. (c) If... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and...) Has remote readouts at the cargo control station. (2) If vacuum protection is required under § 154.804...

  2. 46 CFR 154.1335 - Pressure and vacuum protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... audible and visual alarm at the cargo control station, and a remote group alarm in the wheelhouse. (c) If... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and...) Has remote readouts at the cargo control station. (2) If vacuum protection is required under § 154.804...

  3. 46 CFR 154.1335 - Pressure and vacuum protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... audible and visual alarm at the cargo control station, and a remote group alarm in the wheelhouse. (c) If... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and...) Has remote readouts at the cargo control station. (2) If vacuum protection is required under § 154.804...

  4. Rotating Aperture System

    DOEpatents

    Rusnak, Brian; Hall, James M.; Shen, Stewart; Wood, Richard L.

    2005-01-18

    A rotating aperture system includes a low-pressure vacuum pumping stage with apertures for passage of a deuterium beam. A stator assembly includes holes for passage of the beam. The rotor assembly includes a shaft connected to a deuterium gas cell or a crossflow venturi that has a single aperture on each side that together align with holes every rotation. The rotating apertures are synchronized with the firing of the deuterium beam such that the beam fires through a clear aperture and passes into the Xe gas beam stop. Portions of the rotor are lapped into the stator to improve the sealing surfaces, to prevent rapid escape of the deuterium gas from the gas cell.

  5. Trapped particles at a magnetic discontinuity

    NASA Technical Reports Server (NTRS)

    Stern, D. P.

    1972-01-01

    At a tangential discontinuity between two constant magnetic fields a layer of trapped particles can exist, this work examines the conditions under which the current carried by such particles tends to maintain the discontinuity. Three cases are examined. If the discontinuity separates aligned vacuum fields, the only requirement is that they be antiparallel. With arbitrary relative orientations, the field must have equal intensities on both sides. Finally, with a guiding center plasma on both sides, the condition reduces to a relation which is also derivable from hydromagnetic theory. Arguments are presented for the occurrence of such trapped modes in the magnetopause and for the non-existence of specular particle reflection.

  6. Photogrammetry on the identification of postural asymmetries in cadets and pilots of the Brazilian air force academy.

    PubMed

    Figueiredo, Rodrigo V; Amaral, Artur C; Shimano, Antônio C

    2012-01-01

    To identify whether flight training activities cause postural changes in cadets and pilots of the Brazilian Air Force Academy (AFA). Eighty subjects were assessed through photographic images in anterior and right side views. Four groups of cadets (n=20 per group) divided according to the year since enlistment and a fifth group of fifteen pilots from the Air Demonstration Squadron (ADS) were included. Pictures were analyzed using the Postural Analysis Program (SAPO) and angles related to head vertical alignment (HVA), head horizontal alignment (HHA), acromion horizontal alignment (AHA) and anterior-superior iliac spine horizontal alignment (HAS) were plotted. We did not find statistical significant differences in the angles: HVA, HHA and AHA. However, a significant difference was found for the HAS angle with pilots having lower values than cadets, suggesting greater postural stability for this variable in pilots. The horizontal alignment of the anterior-superior iliac spine was the only measure that showed significant difference in the comparison between pilots and cadets. The remaining alignments were not different, possibility because of the strict criteria used for admission of cadets at the AFA and the efficiency of the physical training that is performed periodically.

  7. Vacuum ultraviolet trimming of oxygenated functional groups from oxidized self-assembled hexadecyl monolayers in an evacuated environment

    NASA Astrophysics Data System (ADS)

    Soliman, Ahmed I. A.; Utsunomiya, Toru; Ichii, Takashi; Sugimura, Hiroyuki

    2017-09-01

    Vacuum ultraviolet light irradiation in dry air generates active oxygen species, which have powerful oxidation abilities. These active oxygen species (O) can oxidize the alkyl moieties of polymers, and generate new oxygenated groups such as OH, CHO and COOH groups. Reducing the oxygen content in the exposure environment decreases the rate of oxidation processes. In this study, we examined the influences of the 172 nm VUV irradiation in a high vacuum (HV, < 10-3 Pa) environment on the chemical constituents, surface properties and morphological structure of well-defined VUV/(O)-modified hexadecyl (HD-) self-assembled monolayer (SAM) prepared on hydrogen-terminated silicon (H-Si) substrate. After VUV light irradiation in a HV environment (HV-VUV), the chemical constituents and surface properties were changed in two distinct stages. At short irradiation time (the first stage), the Csbnd O and COO groups decreased rapidly, while the Cdbnd O groups slightly changed. The dissociation of nonderivatizable groups (such as ether (Csbnd Osbnd C) and ester (Csbnd COOsbnd C) groups) compensated the dissociated OH, CHO, Csbnd COsbnd C and COOH groups. With further irradiation (the second stage), the quantities of the oxygenated groups slightly decreased. The carbon skeleton (Csbnd C) of SAM was scarcely dissociated during the HV-VUV treatment. These chemical changes affected the surface properties, such as wettability and morphology.

  8. Molecular systematics of terraranas (Anura: Brachycephaloidea) with an assessment of the effects of alignment and optimality criteria.

    PubMed

    Padial, José M; Grant, Taran; Frost, Darrel R

    2014-06-26

    Brachycephaloidea is a monophyletic group of frogs with more than 1000 species distributed throughout the New World tropics, subtropics, and Andean regions. Recently, the group has been the target of multiple molecular phylogenetic analyses, resulting in extensive changes in its taxonomy. Here, we test previous hypotheses of phylogenetic relationships for the group by combining available molecular evidence (sequences of 22 genes representing 431 ingroup and 25 outgroup terminals) and performing a tree-alignment analysis under the parsimony optimality criterion using the program POY. To elucidate the effects of alignment and optimality criterion on phylogenetic inferences, we also used the program MAFFT to obtain a similarity-alignment for analysis under both parsimony and maximum likelihood using the programs TNT and GARLI, respectively. Although all three analytical approaches agreed on numerous points, there was also extensive disagreement. Tree-alignment under parsimony supported the monophyly of the ingroup and the sister group relationship of the monophyletic marsupial frogs (Hemiphractidae), while maximum likelihood and parsimony analyses of the MAFFT similarity-alignment did not. All three methods differed with respect to the position of Ceuthomantis smaragdinus (Ceuthomantidae), with tree-alignment using parsimony recovering this species as the sister of Pristimantis + Yunganastes. All analyses rejected the monophyly of Strabomantidae and Strabomantinae as originally defined, and the tree-alignment analysis under parsimony further rejected the recently redefined Craugastoridae and Pristimantinae. Despite the greater emphasis in the systematics literature placed on the choice of optimality criterion for evaluating trees than on the choice of method for aligning DNA sequences, we found that the topological differences attributable to the alignment method were as great as those caused by the optimality criterion. Further, the optimal tree-alignment indicates that insertions and deletions occurred in twice as many aligned positions as implied by the optimal similarity-alignment, confirming previous findings that sequence turnover through insertion and deletion events plays a greater role in molecular evolution than indicated by similarity-alignments. Our results also provide a clear empirical demonstration of the different effects of wildcard taxa produced by missing data in parsimony and maximum likelihood analyses. Specifically, maximum likelihood analyses consistently (81% bootstrap frequency) provided spurious resolution despite a lack of evidence, whereas parsimony correctly depicted the ambiguity due to missing data by collapsing unsupported nodes. We provide a new taxonomy for the group that retains previously recognized Linnaean taxa except for Ceuthomantidae, Strabomantidae, and Strabomantinae. A phenotypically diagnosable superfamily is recognized formally as Brachycephaloidea, with the informal, unranked name terrarana retained as the standard common name for these frogs. We recognize three families within Brachycephaloidea that are currently diagnosable solely on molecular grounds (Brachycephalidae, Craugastoridae, and Eleutherodactylidae), as well as five subfamilies (Craugastorinae, Eleutherodactylinae, Holoadeninae, Phyzelaphryninae, and Pristimantinae) corresponding in large part to previous families and subfamilies. Our analyses upheld the monophyly of all tested genera, but we found numerous subgeneric taxa to be non-monophyletic and modified the taxonomy accordingly.

  9. Electronic structure investigation of atomic layer deposition ruthenium(oxide) thin films using photoemission spectroscopy

    NASA Astrophysics Data System (ADS)

    Schaefer, Michael; Schlaf, Rudy

    2015-08-01

    Analyzing and manipulating the electronic band line-up of interfaces in novel micro- and nanoelectronic devices is important to achieve further advancement in this field. Such band alignment modifications can be achieved by introducing thin conformal interfacial dipole layers. Atomic layer deposition (ALD), enabling angstrom-precise control over thin film thickness, is an ideal technique for this challenge. Ruthenium (Ru0) and its oxide (RuO2) have gained interest in the past decade as interfacial dipole layers because of their favorable properties like metal-equivalent work functions, conductivity, etc. In this study, initial results of the electronic structure investigation of ALD Ru0 and RuO2 films via photoemission spectroscopy are presented. These experiments give insight into the band alignment, growth behavior, surface structure termination, and dipole formation. The experiments were performed in an integrated vacuum system attached to a home-built, stop-flow type ALD reactor without exposing the samples to the ambient in between deposition and analysis. Bis(ethylcyclopentadienyl)ruthenium(II) was used as precursor and oxygen as reactant. The analysis chamber was outfitted with X-ray photoemission spectroscopy (LIXPS, XPS). The determined growth modes are consistent with a strong growth inhibition situation with a maximum average growth rate of 0.21 Å/cycle for RuO2 and 0.04 Å/cycle for Ru.0 An interface dipole of up to -0.93 eV was observed, supporting the assumption of a strongly physisorbed interface. A separate experiment where the surface of a RuO film was sputtered suggests that the surface is terminated by an intermediate, stable, non-stoichiometric RuO2/OH compound whose surface is saturated with hydroxyl groups.

  10. Near-Net-Shape Processing of Sintered Fibrous Ceramics Achieved

    NASA Technical Reports Server (NTRS)

    Angel, Paul W.

    2000-01-01

    A variety of sintered fibrous ceramic (SFC) materials have been developed over the last 50 years as thermal barrier materials for reentry applications. SFC materials typically exhibit very low thermal conductivities combined with low densities and good thermal stability up to 2500 F. These materials have flown successfully on the space shuttle orbiters since the 1960's. More recently, the McDonnell Douglas Corporation successfully used SFC tiles as a heat shield on the underside of its DC X test vehicle. For both of these applications, tiles are machined from blocks of a specific type of SFC called an alumina-enhanced thermal barrier (AETB). The sizes of these blocks have been limited by the manufacturing process. In addition, as much as 80 to 90 percent of the material can be lost during the machining of tiles with significant amounts of curvature. To address these problems, the NASA Glenn Research Center at Lewis Field entered a cooperative contract with the Boeing Company to develop a vacuum-assisted forming process that can produce large (approximately 4 square feet), severely contoured panels of AETB while saving costs in comparison to the conventional cast-and-machine billet process. For shuttle use, AETB is slurry cast, drained, and fired to form square billets conforming to the shape of the filtration box. The billets are then cut into tiles of the appropriate size for thermally protecting the space shuttle. Processing techniques have limited the maximum size of AETB billets to 21.5 square inches by 6.5-in. thick, but the space shuttles use discrete heat shield tiles no more than 8 to 12 square inches. However, in other applications, large, complex shapes are needed, and the tiling approach is undesirable. For such applications, vacuum-assisted forming can produce large parts with complex shapes while reducing machining waste and eliminating cemented joints between bonded billets. Because it allows contoured shapes to be formed, material utilization is inherently high. Initial estimates show that the amount of material lost during machining can be reduced by 50 percent or more. In addition, a fiber alignment favorable for minimum heat transfer is maintained for all panel shapes since the fibers are aligned parallel to the contoured surface of the forming tool or mold. The vacuum-assisted forming process can complete the entire forming operation in a matter of minutes and can produce multiple parts whose size is limited only by the size of the forming tool. To date, panels as large as 2 square feet have been demonstrated The vacuum-assisted forming process starts with the fabrication of a permeable forming tool, or mold, with the proper part contour. This reusable tool is mounted over an internal rib support structure, as depicted in the diagram, such that a vacuum can be pulled on the bottom portion of the tool. AETB slurry is then poured over and around the tool, liquid is drawn from the slurry, and the part forms over the tool surface. The part is then dried, fired, and finished machined. Future plans include an evaluation of the need for additional coatings and surface-toughness treatments to extend the durability and performance of this material.

  11. Vacuum cleaner emissions as a source of indoor exposure to airborne particles and bacteria.

    PubMed

    Knibbs, Luke D; He, Congrong; Duchaine, Caroline; Morawska, Lidia

    2012-01-03

    Vacuuming can be a source of indoor exposure to biological and nonbiological aerosols, although there are few data that describe the magnitude of emissions from the vacuum cleaner itself. We therefore sought to quantify emission rates of particles and bacteria from a large group of vacuum cleaners and investigate their potential determinants, including temperature, dust bags, exhaust filters, price, and age. Emissions of particles between 0.009 and 20 μm and bacteria were measured from 21 vacuums. Ultrafine (<100 nm) particle emission rates ranged from 4.0 × 10(6) to 1.1 × 10(11) particles min(-1). Emission of 0.54-20 μm particles ranged from 4.0 × 10(4) to 1.2 × 10(9) particles min(-1). PM(2.5) emissions were between 2.4 × 10(-1) and 5.4 × 10(3) μg min(-1). Bacteria emissions ranged from 0 to 7.4 × 10(5) bacteria min(-1) and were poorly correlated with dust bag bacteria content and particle emissions. Large variability in emission of all parameters was observed across the 21 vacuums, which was largely not attributable to the range of determinant factors we assessed. Vacuum cleaner emissions contribute to indoor exposure to nonbiological and biological aerosols when vacuuming, and this may vary markedly depending on the vacuum used.

  12. Gas chromatography/matrix-isolation apparatus

    DOEpatents

    Reedy, G.T.

    1986-06-10

    A gas-sample collection device provides matrix isolation of individual gas bands from a gas chromatographic separation and for the spectroscopic analysis of the individual sample bands. The device includes a vacuum chamber containing a rotatably supported, specular carousel having at least one reflecting surface for holding a sample deposited thereon. A gas inlet is provided for depositing a mixture of sample and matrix material on the reflecting surface which is maintained at a sufficiently low temperature to cause solidification. A first parabolic mirror directs an incident beam of electromagnetic radiation, such as in the infrared (IR) spectrum, from a source onto the sample/matrix mixture while a second parabolic mirror directs a second beam of electromagnetic radiation reflected by the specular surface to an IR spectrometer for determining the absorption spectra of the sample material deposited on the reflecting surface. The pair of off-axis parabolic mirrors having a common focal point are positioned outside of the vacuum chamber and may be displaced in combination for improved beam positioning and alignment. The carousel is provided with an aperture for each reflecting surface to facilitate accurate positioning of the incident beam relative to the gas-samples under analysis. Improved gas-sample deposition is insured by the use of a long focal length stereomicroscope positioned outside of the vacuum chamber for monitoring sample formation through a window, while the sample collector is positioned outside of the zone bounded by the incident and reflected electromagnetic beams for improved sample access and monitoring. 10 figs.

  13. Gas chromatography/matrix-isolation apparatus

    DOEpatents

    Reedy, Gerald T.

    1986-01-01

    A gas-sample collection device provides matrix isolation of individual gas bands from a gas chromatographic separation and for the spectroscopic analysis of the individual sample bands. The device includes a vacuum chamber containing a rotatably supported, specular carousel having at least one reflecting surface for holding a sample deposited thereon. A gas inlet is provided for depositing a mixture of sample and matrix material on the reflecting surface which is maintained at a sufficiently low temperature to cause solidification. A first parabolic mirror directs an incident beam of electromagnetic radiation, such as in the infrared (IR) spectrum, from a source onto the sample/matrix mixture while a second parabolic mirror directs a second beam of electromagnetic radiation reflected by the specular surface to an IR spectrometer for determining the absorption spectra of the sample material deposited on the reflecting surface. The pair of off-axis parabolic mirrors having a common focal point are positioned outside of the vacuum chamber and may be displaced in combination for improved beam positioning and alignment. The carousel is provided with an aperture for each reflecting surface to facilitate accurate positioning of the incident beam relative to the gas-samples under analysis. Improved gas-sample deposition is insured by the use of a long focal length stereomicroscope positioned outside of the vacuum chamber for monitoring sample formation through a window, while the sample collector is positioned outside of the zone bounded by the incident and reflected electromagnetic beams for improved sample access and monitoring.

  14. Effects of physical interventions on house dust mite allergen levels in carpet, bed, and upholstery dust in low-income, urban homes.

    PubMed Central

    Vojta, P J; Randels, S P; Stout, J; Muilenberg, M; Burge, H A; Lynn, H; Mitchell, H; O'Connor, G T; Zeldin, D C

    2001-01-01

    House dust mite allergen exposure is a postulated risk factor for allergic sensitization, asthma development, and asthma morbidity; however, practical and effective methods to mitigate these allergens from low-income, urban home environments remain elusive. The purpose of this study was to assess the feasibility and effectiveness of physical interventions to mitigate house dust mite allergens in this setting. Homes with high levels of house dust mite allergen (Der f 1 + Der p 1 > or = 10 microg/g dust by enzyme-linked immunosorbent assay) in the bed, bedroom carpet, and/or upholstered furniture were enrolled in the study. Carpets and upholstered furniture were subjected to a single treatment of either dry steam cleaning plus vacuuming (carpet only) or intensive vacuuming alone. Bed interventions consisted of complete encasement of the mattress, box spring, and pillows plus either weekly professional or in-home laundering of nonencased bedding. Dust samples were collected at baseline and again at 3 days (carpet and upholstery only) and 2, 4, and 8 weeks posttreatment. We compared pretreatment mean allergen concentrations and loads to posttreatment values and performed between-group analyses after adjusting for differences in the pretreatment means. Both dry steam cleaning plus vacuuming and vacuuming alone resulted in a significant reduction in carpet house dust mite allergen concentration and load (p < 0.05). Levels approached pretreatment values by 4 weeks posttreatment in the intensive vacuuming group, whereas steam cleaning plus vacuuming effected a decrease that persisted for up to 8 weeks. Significant decreases in bed house dust mite allergen concentration and load were obtained in response to encasement and either professional or in-home laundering (p < 0.001). Between-group analysis revealed significantly less postintervention house dust mite allergen load in professionally laundered compared to home-laundered beds (p < 0.05). Intensive vacuuming and dry steam cleaning both caused a significant reduction in allergen concentration and load in upholstered furniture samples (p < 0.005). Based on these data, we conclude that physical interventions offer practical, effective means of reducing house dust mite allergen levels in low-income, urban home environments. PMID:11564617

  15. Effect of vacuum and of strong adsorbed water films on micropore formation in aluminum hydroxide xerogel powders.

    PubMed

    Beruto, Dario T; Botter, Rodolfo; Converti, Attilio

    2009-02-01

    Aluminum hydroxide gels were washed with water, ethanol, methanol and isopropanol to obtain new gels with different liquid phases that were dried either in air at 120 degrees C or under vacuum at 80 degrees C. Drying in air leads to alcoholic xerogels with BET surface areas larger than the aqueous ones. The effect of the alcoholic groups as substitutes of the hydroxyl ones has been discussed to account for the final size of xerogel crystallites. Drying under vacuum decreases the BET surface of the methanol xerogels, but no micropores are formed in all the alcoholic xerogel matrixes. On the contrary, the vacuum drying process changes significantly the microstructure of the aqueous xerogels. Their BET surface increases by 34 m(2)/g, and micropores are formed within their crystallite aggregates. It has been experimentally shown that these changes are due to a shear transformation that occurs in the boehmite xerogels obtained under vacuum. To discuss these data, the existence of chemical compounds such as AlOOHnH(2)O was postulated. On this ground, a neat analogy between vacuum drying process and vacuum interfacial decomposition reactions of inorganic salts can be drawn. This analogy explains how a state of stresses forms in aqueous xerogel matrix during vacuum drying process.

  16. An additional reference axis improves femoral rotation alignment in image-free computer navigation assisted total knee arthroplasty.

    PubMed

    Inui, Hiroshi; Taketomi, Shuji; Nakamura, Kensuke; Sanada, Takaki; Tanaka, Sakae; Nakagawa, Takumi

    2013-05-01

    Few studies have demonstrated improvement in accuracy of rotational alignment using image-free navigation systems mainly due to the inconsistent registration of anatomical landmarks. We have used an image-free navigation for total knee arthroplasty, which adopts the average algorithm between two reference axes (transepicondylar axis and axis perpendicular to the Whiteside axis) for femoral component rotation control. We hypothesized that addition of another axis (condylar twisting axis measured on a preoperative radiograph) would improve the accuracy. One group using the average algorithm (double-axis group) was compared with the other group using another axis to confirm the accuracy of the average algorithm (triple-axis group). Femoral components were more accurately implanted for rotational alignment in the triple-axis group (ideal: triple-axis group 100%, double-axis group 82%, P<0.05). Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Self aligned hysteresis free carbon nanotube field-effect transistors

    NASA Astrophysics Data System (ADS)

    Shlafman, M.; Tabachnik, T.; Shtempluk, O.; Razin, A.; Kochetkov, V.; Yaish, Y. E.

    2016-04-01

    Hysteresis phenomenon in the transfer characteristics of carbon nanotube field effect transistor (CNT FET) is being considered as the main obstacle for successful realization of electronic devices based on CNTs. In this study, we prepare four kinds of CNTFETs and explore their hysteretic behavior. Two kinds of devices comprise on-surface CNTs (type I) and suspended CNTs (type II) with thin insulating layer underneath and a single global gate which modulates the CNT conductance. The third and fourth types (types III and IV) consist of suspended CNT over a metallic local gate underneath, where for type IV the local gate was patterned self aligned with the source and drain electrodes. The first two types of devices, i.e., type I and II, exhibit substantial hysteresis which increases with scanning range and sweeping time. Under high vacuum conditions and moderate electric fields ( |E |>4 ×106 V /cm ), the hysteresis for on-surface devices cannot be eliminated, as opposed to suspended devices. Interestingly, type IV devices exhibit no hysteresis at all at ambient conditions, and from the different roles which the global and local gates play for the four types of devices, we could learn about the hysteresis mechanism of this system. We believe that these self aligned hysteresis free FETs will enable the realization of different electronic devices and sensors based on CNTs.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shao, Tao, E-mail: st@mail.iee.ac.cn; Yang, Wenjin; Zhang, Cheng

    Polymer materials, such as polymethylmethacrylate (PMMA), are widely used as insulators in vacuum. The insulating performance of a high-voltage vacuum system is mainly limited by surface flashover of the insulators rather than bulk breakdown. Non-thermal plasmas are an efficient method to modify the chemical and physical properties of polymer material surfaces, and enhance the surface insulating performance. In this letter, an atmospheric-pressure dielectric barrier discharge is used to treat the PMMA surface to improve the surface flashover strength in vacuum. Experimental results indicate that the plasma treatment method using Ar and CF{sub 4} (10:1) as the working gas can etchmore » the PMMA surface, introduce fluoride groups to the surface, and then alter the surface characteristics of the PMMA. The increase in the surface roughness can introduce physical traps that can capture free electrons, and the fluorination can enhance the charge capturing ability. The increase in the surface roughness and the introduction of the fluoride groups can enhance the PMMA hydrophobic ability, improve the charge capturing ability, decrease the secondary electron emission yield, increase the surface resistance, and improve the surface flashover voltage in vacuum.« less

  19. Vacuum impregnation: a promising way for mineral fortification in potato porous matrix (potato chips).

    PubMed

    Joshi, Alka; Kar, A; Rudra, S G; Sagar, V R; Varghese, E; Lad, M; Khan, I; Singh, B

    2016-12-01

    Potato chips can be considered as an ideal carrier for targeted nutrient/s delivery as mostly consumed by the vulnerable group (children and teen agers). The present study was planned to fortifiy potato chips with calcium (Calcium lactate) and zinc (Zinc sulphate) using vacuum impregnation technique. At about 70-80 mm Hg vacuum pressure, maximum level of impregnation of both the minerals was achieved. Results showed that after optimization, calcium lactate at 4.81%, zinc sulphate at 0.72%, and vacuum of 33.53 mm Hg with restoration period of 19.52 min can fortify potato chips that can fulfil 10 and 21% need of calcium and zinc, respectively of targeted group (age 4-17 years). The present research work has shown that through this technique, fortification can be done in potato chips which are generally considered as a poor source of minerals. Further to make potato chips more fit to health conscious consumers, rather frying microwaving was done to develop mineral fortified low fat potato chips.

  20. A Novel Method to Decontaminate Surgical Instruments for Operational and Austere Environments.

    PubMed

    Knox, Randy W; Demons, Samandra T; Cunningham, Cord W

    2015-12-01

    The purpose of this investigation was to test a field-expedient, cost-effective method to decontaminate, sterilize, and package surgical instruments in an operational (combat) or austere environment using chlorhexidine sponges, ultraviolet C (UVC) light, and commercially available vacuum sealing. This was a bench study of 4 experimental groups and 1 control group of 120 surgical instruments. Experimental groups were inoculated with a 10(6) concentration of common wound bacteria. The control group was vacuum sealed without inoculum. Groups 1, 2, and 3 were first scrubbed with a chlorhexidine sponge, rinsed, and dried. Group 1 was then packaged; group 2 was irradiated with UVC light, then packaged; group 3 was packaged, then irradiated with UVC light through the bag; and group 4 was packaged without chlorhexidine scrubbing or UVC irradiation. The UVC was not tested by itself, as it does not grossly clean. The instruments were stored overnight and tested for remaining colony forming units (CFU). Data analysis was conducted using analysis of variance and group comparisons using the Tukey method. Group 4 CFU was statistically greater (P < .001) than the control group and groups 1 through 3. There was no statistically significant difference between the control group and groups 1 through 3. Vacuum sealing of chlorhexidine-scrubbed contaminated instruments with and without handheld UVC irradiation appears to be an acceptable method of field decontamination. Chlorhexidine scrubbing alone achieved a 99.9% reduction in CFU, whereas adding UVC before packaging achieved sterilization or 100% reduction in CFU, and UVC through the bag achieved disinfection. Published by Elsevier Inc.

  1. Alignment-free genome tree inference by learning group-specific distance metrics.

    PubMed

    Patil, Kaustubh R; McHardy, Alice C

    2013-01-01

    Understanding the evolutionary relationships between organisms is vital for their in-depth study. Gene-based methods are often used to infer such relationships, which are not without drawbacks. One can now attempt to use genome-scale information, because of the ever increasing number of genomes available. This opportunity also presents a challenge in terms of computational efficiency. Two fundamentally different methods are often employed for sequence comparisons, namely alignment-based and alignment-free methods. Alignment-free methods rely on the genome signature concept and provide a computationally efficient way that is also applicable to nonhomologous sequences. The genome signature contains evolutionary signal as it is more similar for closely related organisms than for distantly related ones. We used genome-scale sequence information to infer taxonomic distances between organisms without additional information such as gene annotations. We propose a method to improve genome tree inference by learning specific distance metrics over the genome signature for groups of organisms with similar phylogenetic, genomic, or ecological properties. Specifically, our method learns a Mahalanobis metric for a set of genomes and a reference taxonomy to guide the learning process. By applying this method to more than a thousand prokaryotic genomes, we showed that, indeed, better distance metrics could be learned for most of the 18 groups of organisms tested here. Once a group-specific metric is available, it can be used to estimate the taxonomic distances for other sequenced organisms from the group. This study also presents a large scale comparison between 10 methods--9 alignment-free and 1 alignment-based.

  2. The paravertebral muscle and psoas for the maintenance of global spinal alignment in patient with degenerative lumbar scoliosis.

    PubMed

    Yagi, Mitsuru; Hosogane, Naobumi; Watanabe, Kota; Asazuma, Takashi; Matsumoto, Morio

    2016-04-01

    Various factors are reported to affect the spinal alignment in degenerative lumbar scoliosis (DLS). Although trunk muscles also appear to affect spinal alignment, the role of the trunk muscles is not yet clear. The aim was to elucidate the role of the multifidus (MF) and psoas (PS) in maintaining global spinal alignment in patients with DLS. This was a multicenter retrospective matched cohort study. Surgically treated 60 paired DLS and lumbar spinal stenosis (LSS) female (120 patients), matched for age and body mass index (BMI; DLS age 68.0±6.8 vs. LSS 67.1±8.9 years; BMI 21.6±3.3 vs. 23.2±3.8 kg/m(2)), were included and were followed for at least 2 years. Spinal alignment, muscle area, and volume were measured from radiographs, magnetic resonance images (MRIs), and whole-body dual-energy X-ray absorptiometry (DXA) scans. Muscle strength was measured by grip power and peak expiratory flow (PEF). As a surrogate of muscle area, we obtained the cross-sectional area (CSA) at the L5-S level from preoperative MRIs. The MF and PS CSAs were significantly smaller in the DLS group than in the LSS group (MF 477.7±192.5 vs. 779.8±248.6 mm(2), p<.01; PS 692.3±201.2 vs. 943.4±272.4 mm(2), p=.002), whereas percentage of difference between the right and left sides was significantly larger in the DLS group (MF 18.4±30.6 vs. 2.4±3.3%, p<.01; PS 14.4±15.8 vs. 2.1±2.2%, p<.01). In the extremities, there were no significant differences in the left- or right-side lean composition and grip strength or PEF tests between the groups. Correlation coefficient tests showed moderate correlations between the MF average CSA (avCSA) and global spinal alignment and spinopelvic alignment (pelvic incidence-lumbar lordosis; R=-0.37, -0.38) in the DLS group. The MF avCSA was correlated with the postoperative progression of kyphosis at the unfused thoracic vertebrae in the DLS group (R=0.34). The CSAs of the MF and PS were significantly smaller in the DLS group. Whole-body DXA showed no significant difference in the lean composition between the groups. There were significant correlations in the DLS patients between the MF CSA and sagittal spinal alignment. These findings suggest the causal relationship between muscles and global spine alignment. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Effects of epidural lidocaine analgesia on labor and delivery: A randomized, prospective, controlled trial

    PubMed Central

    Nafisi, Shahram

    2006-01-01

    Background Whether epidural analgesia for labor prolongs the active-first and second labor stages and increases the risk of vacuum-assisted delivery is a controversial topic. Our study was conducted to answer the question: does lumbar epidural analgesia with lidocaine affect the progress of labor in our obstetric population? Method 395 healthy, nulliparous women, at term, presented in spontaneous labor with a singleton vertex presentation. These patients were randomized to receive analgesia either, epidural with bolus doses of 1% lidocaine or intravenous, with meperidine 25 to 50 mg when their cervix was dilated to 4 centimeters. The duration of the active-first and second stages of labor and the neonatal apgar scores were recorded, in each patient. The total number of vacuum-assisted and cesarean deliveries were also measured. Results 197 women were randomized to the epidural group. 198 women were randomized to the single-dose intravenous meperidine group. There was no statistical difference in rates of vacuum-assisted delivery rate. Cesarean deliveries, as a consequence of fetal bradycardia or dystocia, did not differ significantly between the groups. Differences in the duration of the active-first and the second stages of labor were not statistically significant. The number of newborns with 1-min and 5-min Apgar scores less than 7, did not differ significantly between both analgesia groups. Conclusion Epidural analgesia with 1% lidocaine does not prolong the active-first and second stages of labor and does not increase vacuum-assisted or cesarean delivery rate. PMID:17176461

  4. Self aligning electron beam gun having enhanced thermal and mechanical stability

    DOEpatents

    Scarpetti, Jr., Raymond D.; Parkison, Clarence D.; Switzer, Vernon A.; Lee, Young J.; Sawyer, William C.

    1995-01-01

    A compact, high power electron gun having enhanced thermal and mechanical stability which incorporates a mechanically coupled, self aligning structure for the anode and cathode. The enhanced stability, and reduced need for realignment of the cathode to the anode and downstream optics during operation are achieved by use of a common support structure for the cathode and anode which requires no adjustment screws or spacers. The electron gun of the present invention also incorporates a modular design for the cathode, in which the electron emitter, its support structure, and the hardware required to attach the emitter assembly to the rest of the gun are a single element. This modular design makes replacement of the emitter simpler and requires no realignment after a new emitter has been installed. Compactness and a reduction in the possibility of high voltage breakdown are achieved by shielding the "triple point" where the electrode, insulator, and vacuum meet. The use of electric discharge machining (EDM) for fabricating the emitter allows for the accurate machining of the emitter into intricate shapes without encountering the normal stresses developed by standard emitter fabrication techniques.

  5. Step-by-step growth of epitaxially aligned polythiophene by surface-confined reaction

    PubMed Central

    Lipton-Duffin, J. A.; Miwa, J. A.; Kondratenko, M.; Cicoira, F.; Sumpter, B. G.; Meunier, V.; Perepichka, D. F.; Rosei, F.

    2010-01-01

    One of the great challenges in surface chemistry is to assemble aromatic building blocks into ordered structures that are mechanically robust and electronically interlinked—i.e., are held together by covalent bonds. We demonstrate the surface-confined growth of ordered arrays of poly(3,4-ethylenedioxythiophene) (PEDOT) chains, by using the substrate (the 110 facet of copper) simultaneously as template and catalyst for polymerization. Copper acts as promoter for the Ullmann coupling reaction, whereas the inherent anisotropy of the fcc 110 facet confines growth to a single dimension. High resolution scanning tunneling microscopy performed under ultrahigh vacuum conditions allows us to simultaneously image PEDOT oligomers and the copper lattice with atomic resolution. Density functional theory calculations confirm an unexpected adsorption geometry of the PEDOT oligomers, which stand on the sulfur atom of the thiophene ring rather than lying flat. This polymerization approach can be extended to many other halogen-terminated molecules to produce epitaxially aligned conjugated polymers. Such systems might be of central importance to develop future electronic and optoelectronic devices with high quality active materials, besides representing model systems for basic science investigations. PMID:20534511

  6. Directional spectral emissivity measurement system

    NASA Technical Reports Server (NTRS)

    Halyo, Nesim (Inventor); Pandey, Dhirendra K. (Inventor)

    1992-01-01

    Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.

  7. Synthesis, characterization and application of functional carbon nano materials

    NASA Astrophysics Data System (ADS)

    Chu, Jin

    The synthesis, characterizations and applications of carbon nanomaterials, including carbon nanorods, carbon nanosheets, carbon nanohoneycombs and carbon nanotubes were demonstrated. Different growth techniques such as pulsed laser deposition, DC/RF sputtering, hot filament physical vapour deposition, evaporative casting and vacuum filtration methods were introduced or applied for synthesizing carbon nanomaterials. The morphology, chemical compositions, bond structures, electronic, mechanical and sensing properties of the obtained samples were investigated. Tilted well-aligned carbon micro- and nano- hybrid rods were fabricated on Si at different substrate temperatures and incident angles of carbon source beam using the hot filament physical vapour deposition technique. The morphologic surfaces and bond structures of the oblique carbon rod-like structures were investigated by scanning electron microscopy, field emission scanning electron microscopy, transmission electron diffraction and Raman scattering spectroscopy. The field emission behaviour of the fabricated samples was also tested. Carbon nanosheets and nanohoneycombs were also synthesized on Si substrates using a hot filament physical vapor deposition technique under methane ambient and vacuum, respectively. The four-point Au electrodes are then sputtered on the surface of the nanostructured carbon films to form prototypical humidity sensors. The sensing properties of prototypical sensors at different temperature, humidity, direct current, and alternative current voltage were characterized. Linear sensing response of sensors to relative humidity ranging from 11% to 95% is observed at room temperature. Experimental data indicate that the carbon nanosheets based sensors exhibit an excellent reversible behavior and long-term stability. It also has higher response than that of the humidity sensor with carbon nanohoneycombs materials. Conducting composite films containing carbon nanotubes (CNTs) were prepared in two different ways of evaporative casting and vacuum filtration methods using the biopolymer kappa-carrageenan (KC) as a dispersant. Evaporative casting and vacuum filtration film-formation processes were compared by testing electrical properties. Results showed that films produced using vacuum filtration had higher electrical properties than those prepared using the evaporative casting method. The evaporative casted multi walled carbon nanotubes composite films also performed as the best humidity sensor over all other films measured.

  8. Enhanced room temperature gas sensing of aligned Mn3O4 nanorod assemblies functionalized by aluminum anodic membranes.

    PubMed

    John, Neetha; Thomas, Paulose; Divya, K V; Abraham, K E

    2018-08-17

    The study includes a conductometric chemical sensor design using aligned Mn 3 O 4 nanorods. Nanostructuring is an emerging field of prominence due to its capacity to introduce unprecedented properties in materials with potential applications. A hydrothermally prepared in situ Mn 3 O 4 sample appears with an urchin rod-like morphology, which changes to a spherical shape upon annealing. An aluminum anodic membrane/template (AAO) is used for the growth of the nanorods and also as a medium to support the sensor. The aligned Mn 3 O 4 nanorods are formed in the pores of the AAO by vacuum infiltration approach, which is later on annealed. The gold electrical contacts are deposited on the top or bottom ends of the Mn 3 O 4 -embedded AAO to ensure conductometric sensing along the length of the Mn 3 O 4 nanorods. In comparison to the Mn 3 O 4 film-based sensor, the Mn 3 O 4 nanorods in the AAO template have enhanced sensitivity for detecting ethanol and acetone vapor at room temperature. The novel property observed is a result of the large surface area and number of oxygen vacancies of the uniformly aligned and parallel assemblies of the nanorods. The sensor exhibits the lowest response time at 4 s for ethanol and 2 s for acetone at room temperature with a concentration of 50 ppm. The response time is 7 and 5 s, respectively, for 25 ppm. The maximum sensitivities of the sensor at room temperature for ethanol and acetone gases are 67% and 68%, respectively, for 50 ppm concentration. The growth mechanism of the aligned nanorods formed in the AAO template is well established through FESEM analysis. The XPS and HRTEM study give additional evidence for the presence of oxidation states and structure of the prepared nanostructures, respectively.

  9. What to do When Scalar Invariance Fails: The Extended Alignment Method for Multi-Group Factor Analysis Comparison of Latent Means Across Many Groups.

    PubMed

    Marsh, Herbert W; Guo, Jiesi; Parker, Philip D; Nagengast, Benjamin; Asparouhov, Tihomir; Muthén, Bengt; Dicke, Theresa

    2017-01-12

    Scalar invariance is an unachievable ideal that in practice can only be approximated; often using potentially questionable approaches such as partial invariance based on a stepwise selection of parameter estimates with large modification indices. Study 1 demonstrates an extension of the power and flexibility of the alignment approach for comparing latent factor means in large-scale studies (30 OECD countries, 8 factors, 44 items, N = 249,840), for which scalar invariance is typically not supported in the traditional confirmatory factor analysis approach to measurement invariance (CFA-MI). Importantly, we introduce an alignment-within-CFA (AwC) approach, transforming alignment from a largely exploratory tool into a confirmatory tool, and enabling analyses that previously have not been possible with alignment (testing the invariance of uniquenesses and factor variances/covariances; multiple-group MIMIC models; contrasts on latent means) and structural equation models more generally. Specifically, it also allowed a comparison of gender differences in a 30-country MIMIC AwC (i.e., a SEM with gender as a covariate) and a 60-group AwC CFA (i.e., 30 countries × 2 genders) analysis. Study 2, a simulation study following up issues raised in Study 1, showed that latent means were more accurately estimated with alignment than with the scalar CFA-MI, and particularly with partial invariance scalar models based on the heavily criticized stepwise selection strategy. In summary, alignment augmented by AwC provides applied researchers from diverse disciplines considerable flexibility to address substantively important issues when the traditional CFA-MI scalar model does not fit the data. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. Alignment between Satellite and Central Galaxies in the SDSS DR7: Dependence on Large-scale Environment

    NASA Astrophysics Data System (ADS)

    Wang, Peng; Luo, Yu; Kang, Xi; Libeskind, Noam I.; Wang, Lei; Zhang, Youcai; Tempel, Elmo; Guo, Quan

    2018-06-01

    The alignment between satellites and central galaxies has been studied in detail both in observational and theoretical works. The widely accepted fact is that satellites preferentially reside along the major axis of their central galaxy. However, the origin and large-scale environmental dependence of this alignment are still unknown. In an attempt to determine these variables, we use data constructed from Sloan Digital Sky Survey DR7 to investigate the large-scale environmental dependence of this alignment with emphasis on examining the alignment’s dependence on the color of the central galaxy. We find a very strong large-scale environmental dependence of the satellite–central alignment (SCA) in groups with blue centrals. Satellites of blue centrals in knots are preferentially located perpendicular to the major axes of the centrals, and the alignment angle decreases with environment, namely, when going from knots to voids. The alignment angle strongly depends on the {}0.1(g-r) color of centrals. We suggest that the SCA is the result of a competition between satellite accretion within large-scale structure (LSS) and galaxy evolution inside host halos. For groups containing red central galaxies, the SCA is mainly determined by the evolution effect, while for blue central dominated groups, the effect of the LSS plays a more important role, especially in knots. Our results provide an explanation for how the SCA forms within different large-scale environments. The perpendicular case in groups and knots with blue centrals may also provide insight into understanding similar polar arrangements, such as the formation of the Milky Way and Centaurus A’s satellite system.

  11. Effect of Age and Proteoglycan Deficiency on Collagen Fiber Re-Alignment and Mechanical Properties in Mouse Supraspinatus Tendon

    PubMed Central

    Connizzo, Brianne K.; Sarver, Joseph J.; Iozzo, Renato V.; Birk, David E.; Soslowsky, Louis J.

    2013-01-01

    Collagen fiber realignment is one mechanism by which tendon responds to load. Re-alignment is altered when the structure of tendon is altered, such as in the natural process of aging or with alterations of matrix proteins, such as proteoglycan expression. While changes in re-alignment and mechanical properties have been investigated recently during development, they have not been studied in (1) aged tendons, or (2) in the absence of key proteoglycans. Collagen fiber re-alignment and the corresponding mechanical properties are quantified throughout tensile mechanical testing in both the insertion site and the midsubstance of mouse supraspinatus tendons in wild type (WT), decorin-null (Dcn-/-), and biglycan-null (Bgn-/-) mice at three different ages (90 days, 300 days, and 570 days). Percent relaxation was significantly decreased with age in the WT and Dcn-/- tendons, but not in the Bgn-/- tendons. Changes with age were found in the linear modulus at the insertion site where the 300 day group was greater than the 90 day and 570 day group in the Bgn-/- tendons and the 90 day group was smaller than the 300 day and 570 day groups in the Dcn-/- tendons. However, no changes in modulus were found across age in WT tendons were found. The midsubstance fibers of the WT and Bgn-/- tendons were initially less aligned with increasing age. The re-alignment was significantly altered with age in the WT tendons, with older groups responding to load later in the mechanical test. This was also seen in the Dcn-/- midsubstance and the Bgn-/- insertion, but not in the other locations. Although some studies have found changes in the WT mechanical properties with age, this study did not support those findings. However, it did show fiber re-alignment changes at both locations with age, suggesting a breakdown of tendon′s ability to respond to load in later ages. In the proteoglycan-null tendons however, there were changes in the mechanical properties, accompanied only by location-dependent re-alignment changes, suggesting a site-specific role for these molecules in loading. Finally, changes in the mechanical properties did not occur in concert with changes in re-alignment, suggesting that typical mechanical property measurements alone are insufficient to describe how structural alterations affect tendon′s response to load. PMID:23445064

  12. Comparison of the iAssist Handheld Guidance System to Conventional Instruments for Mechanical Axis Restoration in Total Knee Arthroplasty.

    PubMed

    Kinney, Matthew C; Cidambi, Krishna R; Severns, Dustyn L; Gonzales, Francis B

    2018-01-01

    Recent advances in total knee arthroplasty (TKA) include an intelligent instrument system designed to provide intraoperative guidance to reduce mechanical alignment errors. Internal position-sensing technology is integrated into microelectronic pods that attach to cutting blocks. The purpose of this prospective, randomized study was to determine whether this iAssist system enables the surgeon to make more accurate bone resections and better restore the mechanical axis compared to conventional instruments in TKA. We randomized patients undergoing TKA into 2 groups. Group I (n = 25) underwent TKA assisted by the iAssist guidance system, group II (n = 25) underwent TKA using conventional instruments. Preoperative and postoperative mechanical axes were measured from full-length lower extremity radiographs to evaluate alignment. Additional surgical parameters were also assessed, including tourniquet time and blood loss. Patient demographics and preoperative mechanical axis alignments were similar between the groups. Postoperatively, 4.0% of patients had greater than 3° of tibial or femoral component mal-alignment in the guidance-assisted cohort, compared with 36.0% in the conventional group (P < .05). Additionally, group I showed significant improvement in variance seen in both the femoral mechanical axis (1.65° ± 0.17° vs 2.23° ± 0.33°, P < .005) and tibial mechanical axis (1.28° ± 0.13° vs 1.71° ± 0.24°, P < .005) compared to group II. There were no significant differences in tourniquet time (P = .86) or blood loss (P = .39) between groups. Use of the iAssist system in TKA results in an improved postoperative mechanical axis and decreased alignment variability compared to conventional instruments, without significantly increasing operative time. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. A Survey of Thermal Decomposition of Solid Insulations and Its Relevance to Breakdown Mechanisms in Partial Vacuum

    DTIC Science & Technology

    1995-07-01

    and a ductile, rubber compound ( EPDM ) utilized in applications requiring flexible insulation. These tests were typically performed in a vacuum or... EPDM ) rt7l materials, as indicated by the "x". In addition to the more common groups, data is included for a relatively new dielectric film (PBO

  14. Diffeomorphic functional brain surface alignment: Functional demons.

    PubMed

    Nenning, Karl-Heinz; Liu, Hesheng; Ghosh, Satrajit S; Sabuncu, Mert R; Schwartz, Ernst; Langs, Georg

    2017-08-01

    Aligning brain structures across individuals is a central prerequisite for comparative neuroimaging studies. Typically, registration approaches assume a strong association between the features used for alignment, such as macro-anatomy, and the variable observed, such as functional activation or connectivity. Here, we propose to use the structure of intrinsic resting state fMRI signal correlation patterns as a basis for alignment of the cortex in functional studies. Rather than assuming the spatial correspondence of functional structures between subjects, we have identified locations with similar connectivity profiles across subjects. We mapped functional connectivity relationships within the brain into an embedding space, and aligned the resulting maps of multiple subjects. We then performed a diffeomorphic alignment of the cortical surfaces, driven by the corresponding features in the joint embedding space. Results show that functional alignment based on resting state fMRI identifies functionally homologous regions across individuals with higher accuracy than alignment based on the spatial correspondence of anatomy. Further, functional alignment enables measurement of the strength of the anatomo-functional link across the cortex, and reveals the uneven distribution of this link. Stronger anatomo-functional dissociation was found in higher association areas compared to primary sensory- and motor areas. Functional alignment based on resting state features improves group analysis of task based functional MRI data, increasing statistical power and improving the delineation of task-specific core regions. Finally, a comparison of the anatomo-functional dissociation between cohorts is demonstrated with a group of left and right handed subjects. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Planar harmonic polynomials of type B

    NASA Astrophysics Data System (ADS)

    Dunkl, Charles F.

    1999-11-01

    The hyperoctahedral group acting on icons/Journals/Common/BbbR" ALT="BbbR" ALIGN="TOP"/>N is the Weyl group of type B and is associated with a two-parameter family of differential-difference operators {Ti:1icons/Journals/Common/leq" ALT="leq" ALIGN="TOP"/> iicons/Journals/Common/leq" ALT="leq" ALIGN="TOP"/> N}. These operators are analogous to partial derivative operators. This paper finds all the polynomials h on icons/Journals/Common/BbbR" ALT="BbbR" ALIGN="TOP"/>N which are harmonic, icons/Journals/Common/Delta" ALT="Delta" ALIGN="TOP"/>Bh = 0 and annihilated by Ti for i>2, where the Laplacian 0305-4470/32/46/308/img1" ALT="(sum). They are given explicitly in terms of a novel basis of polynomials, defined by generating functions. The harmonic polynomials can be used to find wavefunctions for the quantum many-body spin Calogero model.

  16. Wear resistance of four types of vacuum-formed retainer materials: a laboratory study.

    PubMed

    Raja, Taiyub A; Littlewood, Simon J; Munyombwe, Theresa; Bubb, Nigel L

    2014-07-01

    To investigate the resistance to wear of four different vacuum-formed retainer (VFR) materials: Essix C+, Essix ACE, Duran, and Tru-Tain. Essix C+ is a polypropylene polymer; the other materials are polyethylene co-polymers. The study was undertaken at the Leeds Dental Institute, Leeds, UK, with 26 samples in each group. The specimens were vacuum-formed according to the manufacturers' guidelines, and a custom-made wear-simulation machine was used to conduct the test. Each specimen was subjected to 1000 cycles of the wear simulation, with steatite balls as the antagonist material. The resistance to wear of the VFR materials was evaluated by measuring the maximum wear depth using noncontact, three-dimensional surface profilometry. The wear depth was given in micrometers. The median wear depth was 63.20 µm for the Essix C+ group, 7.88 µm for the Essix ACE group, 9.75 µm for the Duran group, and 12.08 µm for the Tru-Tain group. The Kruskal-Wallis test to compare the four VFR materials detected a statistically significant difference between the groups (P < .001). Comparisons of the groups using the Mann-Whitney U-test demonstrated that the Essix C+ group had significantly greater wear than the other three groups (P < .001). There was no statistically significant difference in median wear depth between the two groups with the least amount of wear-the Essix ACE and Duran groups. Under the standardized conditions of this laboratory study, the three polyethylene co-polymer materials-Essix ACE, Duran, and Tru-Tain-exhibited significantly less wear than the polypropylene material, Essix C+.

  17. Casimir energy between two parallel plates and projective representation of the Poincaré group

    NASA Astrophysics Data System (ADS)

    Akita, Takamaru; Matsunaga, Mamoru

    2016-06-01

    The Casimir effect is a physical manifestation of zero point energy of quantum vacuum. In a relativistic quantum field theory, Poincaré symmetry of the theory seems, at first sight, to imply that nonzero vacuum energy is inconsistent with translational invariance of the vacuum. In the setting of two uniform boundary plates at rest, quantum fields outside the plates have (1 +2 )-dimensional Poincaré symmetry. Taking a massless scalar field as an example, we have examined the consistency between the Poincaré symmetry and the existence of the vacuum energy. We note that, in quantum theory, symmetries are represented projectively in general and show that the Casimir energy is connected to central charges appearing in the algebra of generators in the projective representations.

  18. Tunneling of Bloch electrons through vacuum barrier

    NASA Astrophysics Data System (ADS)

    Mazin, I. I.

    2001-08-01

    Tunneling of Bloch electrons through a vacuum barrier introduces new physical effects in comparison with the textbook case of free (plane wave) electrons. For the latter, the exponential decay rate in the vacuum is minimal for electrons with the parallel component of momentum kparallel = 0, and the prefactor is defined by the electron momentum component in the normal to the surface direction. However, the decay rate of Bloch electrons may be minimal at an arbitrary kparallel ("hot spots" ), and the prefactor is determined by the electron's group velocity, rather than by its quasimomentum. We illustrate this by first-principles calculations for (110) Pd surface.

  19. Design and development of a new SRF cavity cryomodule for the ATLAS intensity upgrade

    NASA Astrophysics Data System (ADS)

    Kedzie, Mark; Conway, Zachary; Fuerst, Joel; Gerbick, Scott; Kelly, Michael; Morgan, James; Ostroumov, Peter; O'Toole, Michael; Shepard, Kenneth

    2012-06-01

    The ATLAS heavy ion linac at Argonne National Laboratory is undergoing an intensity upgrade that includes the development and implementation of a new cryomodule containing four superconducting solenoids and seven quarter-wave drift-tube-loaded superconducting rf cavities. The rf cavities extend the state of the art for this class of structure and feature ASME code stamped stainless steel liquid helium containment vessels. The cryomodule design is a further evolution of techniques recently implemented in a previous upgrade [1]. We provide a status report on the construction effort and describe the vacuum vessel, thermal shield, cold mass support and alignment, and other subsystems including couplers and tuners. Cavity mechanical design is also reviewed.

  20. Establishing guardrails in leadership.

    PubMed

    Kerfoot, Karlene

    2005-01-01

    Shared leadership/governance offers the best environment for growth of the professional staff and for leaders and managers. Tisch (2004) writes that the power of the partnership begins with the recognition that no one can operate effectively in a vacuum and concludes with the premise that partnerships can redefine the traditional business relationships and transform them from adversarial to cooperative. This happens when the road is clearly delineated and guardrails are put in place as reminders of where the car should be on the road. With an atmosphere of learning and partnering to learn more, the leader's job becomes that of teacher, and mentor, and everyone is aligned around the journey to excellence with guardrails in place to monitor the journey.

  1. Effects of toe-in and toe-in with wider step width on level walking knee biomechanics in varus, valgus, and neutral knee alignments.

    PubMed

    Bennett, Hunter J; Shen, Guangping; Cates, Harold E; Zhang, Songning

    2017-12-01

    Increased peak external knee adduction moments exist for individuals with knee osteoarthritis and varus knee alignments, compared to healthy and neutrally aligned counterparts. Walking with increased toe-in or increased step width have been individually utilized to successfully reduce 1st and 2nd peak knee adduction moments, respectfully, but have not previously been combined or tested among all alignment groups. The purpose of this study was to compare toe-in only and toe-in with wider step width gait modifications in individuals with neutral, valgus, and varus alignments. Thirty-eight healthy participants with confirmed varus, neutral, or valgus frontal-plane knee alignment through anteroposterior radiographs, performed level walking in normal, toe-in, and toe-in with wider step width gaits. A 3×3 (group×intervention) mixed model repeated measures ANOVA compared alignment groups and gait interventions (p<0.05). The 1st peak knee adduction moment was reduced in both toe-in and toe-in with wider step width compared to normal gait. The 2nd peak adduction moment was increased in toe-in compared to normal and toe-in with wider step width. The adduction impulse was also reduced in toe-in and toe-in with wider step width compared to normal gait. Peak knee flexion and external rotation moments were increased in toe-in and toe-in with wider step width compared to normal gait. Although the toe-in with wider step width gait seems to be a viable option to reduce peak adduction moments for varus alignments, sagittal, and transverse knee loadings should be monitored when implementing this gait modification strategy. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The effect of tibiotalar alignment on coronal plane mechanics following total ankle replacement.

    PubMed

    Grier, A Jordan; Schmitt, Abigail C; Adams, Samuel B; Queen, Robin M

    2016-07-01

    Gait mechanics following total ankle replacement (TAR) have reported improved ankle motion following surgery. However, no studies have addressed the impact of preoperative radiographic tibiotalar alignment on post-TAR gait mechanics. We therefore investigated whether preoperative tibiotalar alignment (varus, valgus, or neutral) resulted in significantly different coronal plane mechanics or ground reaction forces post-TAR. We conducted a non-randomized study of 93 consecutive end-stage ankle arthritis patients. Standard weight-bearing radiographs were obtained preoperatively to categorize patients as having neutral (±4°), varus (≥5° of varus), or valgus (≥5° of valgus) coronal plane tibiotalar alignment. All patients underwent a standard walking assessment including three-dimensional lower extremity kinetics and kinematics preoperatively, 12 and 24 months postoperatively. A significant group by time interaction was observed for the propulsive vertical ground reaction force (vGRF), coronal plane hip range of motion (ROM) and the peak hip abduction moment. The valgus group demonstrated an increase in the peak knee adduction angle and knee adduction angle at heel strike when compared to the other groups. Coronal plane ankle ROM, knee and hip angles at heel strike, and the peak hip angle exhibited significant increases across time. Peak ankle inversion moment, peak knee abduction moment and the weight acceptance vGRF also exhibited significant increases across time. Neutral ankle alignment was achieved for all patients by 2 years following TAR. Restoration of neutral ankle alignment at the time of TAR in patients with preoperative varus or valgus tibiotalar alignment resulted in biomechanics similar to those of patients with neutral preoperative tibiotalar alignment by 24-month follow-up. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. LCLS-II CRYOMODULE TRANSPORT SYSTEM TESTING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huque, Naeem; Daly, Edward F.; McGee, Michael W.

    The Cryomodules (CM) for the Linear Coherent Light Source II (LCLS-II) will be shipped to SLAC (Menlo Park, California) from JLab (Newport News, Virginia) and FNAL (Batavia, Illinois). A transportation system has been designed and built to safely transport the CMs over the road. It uses an array of helical isolator springs to attenuate shocks on the CM to below 1.5g in all directions. The system rides on trailers equipped with Air-Ride suspension, which attenuates vibration loads. The prototype LCLS-II CM (pCM) was driven 750 miles to test the transport system; shock loggers recorded the shock attenuation on the pCMmore » and vacuum gauges were used to detect any compromises in beamline vacuum. Alignment measurements were taken before and after the trip to check whether cavity positions had shifted beyond the ± 0.2mm spec. Passband frequencies and cavity gradients were measured at 2K at the Cryomodule Test Facility (CMTF) at JLab to identify any degradation of CM performance after transportation. The transport system was found to have safely carried the CM and is cleared to begin shipments from JLab and FNAL to SLAC.« less

  4. Integration of a high-NA light microscope in a scanning electron microscope.

    PubMed

    Zonnevylle, A C; Van Tol, R F C; Liv, N; Narvaez, A C; Effting, A P J; Kruit, P; Hoogenboom, J P

    2013-10-01

    We present an integrated light-electron microscope in which an inverted high-NA objective lens is positioned inside a scanning electron microscope (SEM). The SEM objective lens and the light objective lens have a common axis and focal plane, allowing high-resolution optical microscopy and scanning electron microscopy on the same area of a sample simultaneously. Components for light illumination and detection can be mounted outside the vacuum, enabling flexibility in the construction of the light microscope. The light objective lens can be positioned underneath the SEM objective lens during operation for sub-10 μm alignment of the fields of view of the light and electron microscopes. We demonstrate in situ epifluorescence microscopy in the SEM with a numerical aperture of 1.4 using vacuum-compatible immersion oil. For a 40-nm-diameter fluorescent polymer nanoparticle, an intensity profile with a FWHM of 380 nm is measured whereas the SEM performance is uncompromised. The integrated instrument may offer new possibilities for correlative light and electron microscopy in the life sciences as well as in physics and chemistry. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  5. Active vacuum brazing of CNT films to metal substrates for superior electron field emission performance

    NASA Astrophysics Data System (ADS)

    Longtin, Rémi; Sanchez-Valencia, Juan Ramon; Shorubalko, Ivan; Furrer, Roman; Hack, Erwin; Elsener, Hansrudolf; Gröning, Oliver; Greenwood, Paul; Rupesinghe, Nalin; Teo, Kenneth; Leinenbach, Christian; Gröning, Pierangelo

    2015-02-01

    The joining of macroscopic films of vertically aligned multiwalled carbon nanotubes (CNTs) to titanium substrates is demonstrated by active vacuum brazing at 820 °C with a Ag-Cu-Ti alloy and at 880 °C with a Cu-Sn-Ti-Zr alloy. The brazing methodology was elaborated in order to enable the production of highly electrically and thermally conductive CNT/metal substrate contacts. The interfacial electrical resistances of the joints were measured to be as low as 0.35 Ω. The improved interfacial transport properties in the brazed films lead to superior electron field-emission properties when compared to the as-grown films. An emission current of 150 μA was drawn from the brazed nanotubes at an applied electric field of 0.6 V μm-1. The improvement in electron field-emission is mainly attributed to the reduction of the contact resistance between the nanotubes and the substrate. The joints have high re-melting temperatures up to the solidus temperatures of the alloys; far greater than what is achievable with standard solders, thus expanding the application potential of CNT films to high-current and high-power applications where substantial frictional or resistive heating is expected.

  6. Active vacuum brazing of CNT films to metal substrates for superior electron field emission performance

    PubMed Central

    Longtin, Rémi; Ramon Sanchez-Valencia, Juan; Shorubalko, Ivan; Furrer, Roman; Hack, Erwin; Elsener, Hansrudolf; Gröning, Oliver; Greenwood, Paul; Rupesinghe, Nalin; Teo, Kenneth; Leinenbach, Christian; Gröning, Pierangelo

    2015-01-01

    The joining of macroscopic films of vertically aligned multiwalled carbon nanotubes (CNTs) to titanium substrates is demonstrated by active vacuum brazing at 820 °C with a Ag–Cu–Ti alloy and at 880 °C with a Cu–Sn–Ti–Zr alloy. The brazing methodology was elaborated in order to enable the production of highly electrically and thermally conductive CNT/metal substrate contacts. The interfacial electrical resistances of the joints were measured to be as low as 0.35 Ω. The improved interfacial transport properties in the brazed films lead to superior electron field-emission properties when compared to the as-grown films. An emission current of 150 μA was drawn from the brazed nanotubes at an applied electric field of 0.6 V μm−1. The improvement in electron field-emission is mainly attributed to the reduction of the contact resistance between the nanotubes and the substrate. The joints have high re-melting temperatures up to the solidus temperatures of the alloys; far greater than what is achievable with standard solders, thus expanding the application potential of CNT films to high-current and high-power applications where substantial frictional or resistive heating is expected. PMID:27877755

  7. Transformation Education: A Vehicle for Structuring Group Care Organizations to Increase Service Quality and Effectiveness

    ERIC Educational Resources Information Center

    Ross, Andrew L.

    2007-01-01

    Transformation Education, an organizational philosophy and operating system, is designed to increase service quality and effectiveness of group care through aligning its organizational structure with its purpose. This alignment is achieved through creating a culture designed to dispense transformation rather than treatment. The author presents how…

  8. Radiological outcomes of pinless navigation in total knee arthroplasty: a randomized controlled trial.

    PubMed

    Chen, Jerry Yongqiang; Chin, Pak Lin; Li, Zongxian; Yew, Andy Khye Soon; Tay, Darren Keng Jin; Chia, Shi-Lu; Lo, Ngai Nung; Yeo, Seng Jin

    2015-12-01

    This study aimed to investigate the accuracy of pinless navigation (BrainLAB(®) VectorVision(®) Knee 2.5 Navigation System) as an intra-operative alignment guide in total knee arthroplasty (TKA). The authors hypothesized that pinless navigation would reduce the proportion of outliers in conventional TKA, without a significant increase in the duration of surgery. Between 2011 and 2012, 100 patients scheduled for a unilateral primary TKA were randomized into two groups: pinless navigation and conventional surgery. All TKAs were performed with the surgical aim of achieving neutral coronal alignment with a 180° mechanical axis. The primary outcomes of this study were post-operative radiographic assessment of lower limb alignment using hip-knee-ankle angle (HKA) and components placement using coronal femoral-component angle (CFA) and coronal tibia-component angle (CTA). There was a smaller proportion of outliers for HKA, CFA and CTA at 10, 2 and 2 % respectively, in the pinless navigation group, compared to 32, 16 and 16 %, respectively, in the conventional group (p = 0.013, p = 0.032 and p = 0.032, respectively). The mean CFA was also more accurate at 90° in the pinless navigation group compared to 91° in the conventional group (p = 0.002). There was no difference in the duration of surgery between the two groups (n.s.). Pinless navigation improves lower limb alignment and components placement without a significant increase in the duration of surgery. The authors recommend the use of pinless navigation to verify the coronal alignments of conventional cutting blocks in TKA before the bone cuts are made. I.

  9. Impact of fixed orthodontic appliance or clear-aligner on daily performance, in adult patients with moderate need for treatment

    PubMed Central

    Lin, Feiou; Yao, Linjie; Bhikoo, Chandradev; Guo, Jing

    2016-01-01

    Objective To assess the impact of wearing fixed orthodontic appliance (FOA) or clear-aligner, on daily performance in adult patients. Methods The Oral Impacts on Daily Performance (OIDP) index was assessed in 152 adults aged 25–35 years at baseline (T0), 6 months after bonding (T1), and 12 months after bonding (T2). Participants were randomly divided into two groups: CA group (participants treated with clear-aligner) and a control group (FOA group; participants treated with FOA). Baseline malocclusion severity was assessed using the Index of Orthodontic Treatment Need. Results There were no significant differences in sociodemographic variables and OIDP scores at baseline between the two groups. Significant changes in OIDP total and subscale scores were observed while wearing FOA: OIDP total score and subscale scores of eating, cleaning teeth, smiling, and social relation at T1 and T2 were significantly higher than at baseline (P<0.05 or P<0.01). However, only OIDP total score was significantly increased at T1 compared to the baseline in the CA group. OIDP total score and subscale scores of eating, cleaning teeth, smiling, and social relation were significantly higher in patients wearing FOA than in patients wearing clear-aligner at T1 and T2 (P<0.05 or P<0.01). Conclusion Patients wearing clear-aligner have fewer impacts on daily life than those wearing FOA during treatment, and have no significant changes in OIPD subscale scores at 12 months. FOA therapy significantly impacts daily performance in adult patients during treatment. PMID:27616881

  10. Traction force during vacuum extraction: a prospective observational study.

    PubMed

    Pettersson, K; Ajne, J; Yousaf, K; Sturm, D; Westgren, M; Ajne, G

    2015-12-01

    To investigate the traction force employed during vacuum extractions. Observational cross-sectional study. Obstetric Department, Karolinska University Hospital, Sweden, and the Swedish National Congress of Obstetrics and Gynaecology, 2013. Two hundred women with vacuum extraction at term and 130 obstetricians participating in a simulated setting. In a normal clinical setting, we used a specially adapted device to measure and record the force used to undertake vacuum extraction. In a subsequent part of the study, the force employed for vacuum extraction by a group of obstetricians in a fictive setting was estimated and objectively measured. Applied force during vacuum extraction in relation to the estimated level of difficulty in the delivery; perinatal diagnoses of asphyxia or head trauma; estimated force compared with objectively measured force employed in the fictive setting. The median (minimum-maximum) peak forces for minimum, average and excessive vacuum extraction in the clinical setting were 176 N (5-360 N), 225 N (115-436 N), and 241 N (164-452 N), respectively. In 34% of cases a force in excess of 216 N was employed. There was no correlation between the umbilical arterial pH at delivery and the traction force employed during extraction. Four cases of mild hypoxic ischaemic encephalopathy were observed, three of which were associated with a delivery whereby excessive traction force was employed during the vacuum extraction. In the fictive setting, the actual exerted force was twice the quantitative estimation. The measured forces in the clinical setting were four times higher than that estimated in the fictive setting. Higher than expected levels of traction force were used for vacuum extraction delivery. As obstetricians tend to underestimate the force applied during vacuum extraction, objective measurement with instantaneous feedback may be valuable in raising awareness. © 2015 Royal College of Obstetricians and Gynaecologists.

  11. Effects of sous-vide method at different temperatures, times and vacuum degrees on the quality, structural, and microbiological properties of pork ham.

    PubMed

    Jeong, Kiyoung; O, Hyeonbin; Shin, So Yeon; Kim, Young-Soon

    2018-04-10

    This study evaluated the influence of different factors on pork hams cooked by sous-vide method. The quality and structural and microbiological properties of the treated samples were compared with those of controls. Samples were subjected to treatment at different combinations of temperature (61 °C or 71 °C), time (45 or 90 min), and vacuum degree (98.81% or 96.58%). The control sample was air packaged and boiled for 45 min in boiling water. Temperature and vacuum degree affected quality properties, while the effect of time was limited. Samples cooked at 61 °C showed higher moisture content, redness, and pink color of the meat juice, whereas samples cooked at 71 °C showed higher cooking loss rate, lightness, and volatile basic nitrogen values. Texture analysis indicated tenderer meat for the treatment group than the control. No microbial growth was detected in any treatment groups. Meat cooked at 61 °C and 98.81% vacuum showed more spacious arrangement of meat fiber. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Analysis of Ribosome Inactivating Protein (RIP): A Bioinformatics Approach

    NASA Astrophysics Data System (ADS)

    Jothi, G. Edward Gnana; Majilla, G. Sahaya Jose; Subhashini, D.; Deivasigamani, B.

    2012-10-01

    In spite of the medical advances in recent years, the world is in need of different sources to encounter certain health issues.Ribosome Inactivating Proteins (RIPs) were found to be one among them. In order to get easy access about RIPs, there is a need to analyse RIPs towards constructing a database on RIPs. Also, multiple sequence alignment was done towards screening for homologues of significant RIPs from rare sources against RIPs from easily available sources in terms of similarity. Protein sequences were retrieved from SWISS-PROT and are further analysed using pair wise and multiple sequence alignment.Analysis shows that, 151 RIPs have been characterized to date. Amongst them, there are 87 type I, 37 type II, 1 type III and 25 unknown RIPs. The sequence length information of various RIPs about the availability of full or partial sequence was also found. The multiple sequence alignment of 37 type I RIP using the online server Multalin, indicates the presence of 20 conserved residues. Pairwise alignment and multiple sequence alignment of certain selected RIPs in two groups namely Group I and Group II were carried out and the consensus level was found to be 98%, 98% and 90% respectively.

  13. Management of hidradenitis suppurativa wounds with an internal vacuum-assisted closure device.

    PubMed

    Chen, Y Erin; Gerstle, Theodore; Verma, Kapil; Treiser, Matthew D; Kimball, Alexandra B; Orgill, Dennis P

    2014-03-01

    Hidradenitis suppurativa is a chronic, debilitating disease that is difficult to treat. Once medical management fails, wide local excision offers the best chance for cure. However, the resultant wound often proves too large or contaminated for immediate closure. The authors performed a retrospective chart review of hidradenitis cases managed surgically between 2005 and 2010. Data collected included patient characteristics, management method, and outcomes. Approximately half of the patients received internal vacuum-assisted closure therapy using the vacuum-assisted closure system and delayed closure and half of the patients received immediate primary closure at the time of their excision. Delayed closure consisted of closing the majority of the wound in a linear fashion following internal vacuum-assisted closure while accepting healing by means of secondary intention for small wound areas. Patients managed with internal vacuum-assisted closure had wounds on average four times larger in area than patients managed without internal vacuum-assisted closure. In both groups, all wounds were eventually closed primarily. Healing times averaged 2.2 months with internal vacuum-assisted closure and 2.7 months without. At an average follow-up time of 2.3 months, all patients with internal vacuum-assisted closure had no recurrence of their local disease. Severe hidradenitis presents a treatment challenge, as surgical excisions are often complicated by difficult closures and unsatisfactory recurrence rates. This study demonstrates that wide local excision with reasonable outcomes can be achieved using accelerated delayed primary closure. This method uses internal vacuum-assisted closure as a bridge between excision and delayed primary closure, facilitating closure without recurrence in large, heavily contaminated wounds. Therapeutic, III.

  14. Optical Testing of Retroreflectors for Cryogenic Applications

    NASA Technical Reports Server (NTRS)

    Ohl, Raymond G.; Frey, Bradley J.; Stock, Joseph M.; McMann, Joseph C.; Zukowiski, Tmitri J.

    2010-01-01

    A laser tracker (LT) is an important coordinate metrology tool that uses laser interferometry to determine precise distances to objects, points, or surfaces defined by an optical reference, such as a retroreflector. A retroreflector is a precision optic consisting of three orthogonal faces that returns an incident laser beam nearly exactly parallel to the incident beam. Commercial retroreflectors are designed for operation at room temperature and are specified by the divergence, or beam deviation, of the returning laser beam, usually a few arcseconds or less. When a retroreflector goes to extreme cold (.35 K), however, it could be anticipated that the precision alignment between the three faces and the surface figure of each face would be compromised, resulting in wavefront errors and beam divergence, degrading the accuracy of the LT position determination. Controlled tests must be done beforehand to determine survivability and these LT coordinate errors. Since conventional interferometer systems and laser trackers do not operate in vacuum or at cold temperatures, measurements must be done through a vacuum window, and care must be taken to ensure window-induced errors are negligible, or can be subtracted out. Retroreflector holders must be carefully designed to minimize thermally induced stresses. Changes in the path length and refractive index of the retroreflector have to be considered. Cryogenic vacuum testing was done on commercial solid glass retroreflectors for use on cryogenic metrology tasks. The capabilities to measure wavefront errors, measure beam deviations, and acquire laser tracker coordinate data were demonstrated. Measurable but relatively small increases in beam deviation were shown, and further tests are planned to make an accurate determination of coordinate errors.

  15. Thermal design and validation of radiation detector for the ChubuSat-2 micro-satellite with high-thermal-conductive graphite sheets

    NASA Astrophysics Data System (ADS)

    Park, Daeil; Miyata, Kikuko; Nagano, Hosei

    2017-07-01

    This paper describes thermal design of the radiation detector (RD) for the ChubuSat-2 with the use of high-thermal-conductive materials. ChubuSat-2 satellite is a 50-kg-class micro-satellite joint development with Nagoya University and aerospace companies. The main mission equipment of ChubuSat-2 is a RD to observe neutrons and gamma rays. However, the thermal design of the RD encounters a serious problem, such as no heater for RD and electric circuit alignment constrain. To solve this issue, the RD needs a new thermal design and thermal control for successful space missions. This paper proposes high-thermal-conductive graphite sheets to be used as a flexible radiator fin for the RD. Before the fabrication of the device, the optimal thickness and surface area for the flexible radiator fin were determined by thermal analysis. Consequently, the surface area of flexible radiator fin was determined to be 8.6×104 mm2. To verify the effects of the flexible radiator fin, we constructed a verification model and analyzed the temperature distributions in the RD. Also, the thermal vacuum test was performed using a thermal vacuum chamber, which was evacuated at a pressure of around 10-4 Pa, and its internal temperature was cooled at -80 °C by using a refrigerant. As a result, it has been demonstrated that the flexible radiator fin is effective. And the thermal vacuum test results are presented good correlation with the analysis results.

  16. Radiotherapy setup displacements in breast cancer patients: 3D surface imaging experience.

    PubMed

    Cravo Sá, Ana; Fermento, Ana; Neves, Dalila; Ferreira, Sara; Silva, Teresa; Marques Coelho, Carina; Vaandering, Aude; Roma, Ana; Quaresma, Sérgio; Bonnarens, Emmanuel

    2018-01-01

    In this study, we intend to compare two different setup procedures for female breast cancer patients. Imaging in radiotherapy provides a precise localization of the tumour, increasing the accuracy of the treatment delivery in breast cancer. Twenty breast cancer patients who underwent whole breast radiotherapy (WBRT) were selected for this study. Patients were divided into two groups of ten. Group one (G1) was positioned by tattoos and then the patient positioning was adjusted with the aid of AlignRT (Vision RT, London, UK). In group two (G2), patients were positioned only by tattoos. For both groups, the first 15 fractions were analyzed, a daily kilovoltage (kV) cone beam computed tomography (CBCT) image was made and then the rotational and translational displacements and, posteriorly, the systematic ( Σ ) and random ( σ ) errors were analyzed. The comparison of CBCT displacements for the two groups showed a statistically significant difference in the translational left-right (LR) direction ( ρ  = 0.03), considering that the procedure with AlignRT system has smaller lateral displacements. The results of systematic ( Σ ) and random ( σ ) errors showed that for translational displacements the group positioned only by tattoos (G2) demonstrated higher values of errors when compared with the group positioned with the aid of AlignRT (G1). AlignRT could help the positioning of breast cancer patients; however, it should be used with another imaging method.

  17. Bone morphotypes of the varus and valgus knee.

    PubMed

    Thienpont, E; Schwab, P E; Cornu, O; Bellemans, J; Victor, J

    2017-03-01

    Coronal deformity correction with total knee arthroplasty (TKA) is an important feature in the treatment of osteoarthritis (OA). The hypothesis of this study was that bone morphology would be different in varus and valgus deformity, both before osteoarthritis development as well as during and after the disease process of OA. Retrospective study with measurements on preoperative and postoperative full leg standing radiographs of 96 patients who underwent TKA. The included patients were selected for this study because they had an OA knee on one side and a non-arthritic knee on the contralateral side presenting the same type of alignment as the to-be-operated knee (varus or valgus alignment on both sides). The control group of 46 subjects was a group of patients with neutral mechanical alignment who presented for ligamentous problems. A single observer measured mechanical alignment, anatomical alignment, anatomical-mechanical femoral angle and intra-articular bone morphology parameters with an accuracy of 1°. Varus OA group has less distal femoral valgus (mLDFA 89°) than control group (87°) and valgus OA group (mLDFA 85°). Varus OA group has same varus obliquity as control group (MPTA 87°) but more than valgus OA group (MPTA 90°). Joint Line Congruency Angle (JLCA) is 3°open on lateral side in varus and medially open in valgus OA group (2°). The non-arthritic valgus group presents a constitutional mechanical valgus of 184° Hip-Knee-Ankle (HKA) angle. Varus deformity in OA as measured with an HKA angle (HKA) <177° is a combination of distal femoral wear, tibial varus obliquity and lateral joint line opening. Valgus deformity in OA with an HKA > 183° is a combination of femoral distal joint line obliquity and wear combined with medial opening due to medial collateral ligament stretching. The clinical importance of bone morphotype analysis is that it shows the intra-articular potential of alignment correction when mechanical axis cuts are performed. Bone morphology in varus and valgus deformity is different before and after osteoarthritis. Perpendicular cuts to mechanical axes do not necessarily lead to neutral mechanical axis. Constitutional mechanical valgus was observed as 184° HKA angle before the development of OA. Level IV study.

  18. Evolutionary profiles from the QR factorization of multiple sequence alignments

    PubMed Central

    Sethi, Anurag; O'Donoghue, Patrick; Luthey-Schulten, Zaida

    2005-01-01

    We present an algorithm to generate complete evolutionary profiles that represent the topology of the molecular phylogenetic tree of the homologous group. The method, based on the multidimensional QR factorization of numerically encoded multiple sequence alignments, removes redundancy from the alignments and orders the protein sequences by increasing linear dependence, resulting in the identification of a minimal basis set of sequences that spans the evolutionary space of the homologous group of proteins. We observe a general trend that these smaller, more evolutionarily balanced profiles have comparable and, in many cases, better performance in database searches than conventional profiles containing hundreds of sequences, constructed in an iterative and computationally intensive procedure. For more diverse families or superfamilies, with sequence identity <30%, structural alignments, based purely on the geometry of the protein structures, provide better alignments than pure sequence-based methods. Merging the structure and sequence information allows the construction of accurate profiles for distantly related groups. These structure-based profiles outperformed other sequence-based methods for finding distant homologs and were used to identify a putative class II cysteinyl-tRNA synthetase (CysRS) in several archaea that eluded previous annotation studies. Phylogenetic analysis showed the putative class II CysRSs to be a monophyletic group and homology modeling revealed a constellation of active site residues similar to that in the known class I CysRS. PMID:15741270

  19. Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor

    PubMed Central

    Li, Xiaowei; Ren, Chaochao; Wang, Zheyao; Zhao, Pai; Wang, Hongmei

    2016-01-01

    Objective The purposes of this study were to measure the orthodontic forces generated by thermoplastic aligners and investigate the possible influences of different activations for lingual bodily movements on orthodontic forces, and their attenuation. Methods Thermoplastic material of 1.0-mm in thickness was used to manufacture aligners for 0.2, 0.3, 0.4, 0.5, and 0.6 mm activations for lingual bodily movements of the maxillary central incisor. The orthodontic force in the lingual direction delivered by the thermoplastic aligners was measured using a micro-stress sensor system for the invisible orthodontic technique, and was monitored for 2 weeks. Results Orthodontic force increased with the amount of activation of the aligner in the initial measurements. The attenuation speed in the 0.6 mm group was faster than that of the other groups (p < 0.05). All aligners demonstrated rapid relaxation in the first 8 hours, which then decreased slowly and plateaued on day 4 or 5. Conclusions The amount of activation had a substantial influence on the orthodontic force imparted by the aligners. The results suggest that the activation of lingual bodily movement of the maxillary central incisor should not exceed 0.5 mm. The initial 4 or 5 days is important with respect to orthodontic treatment incorporating an aligner. PMID:27019820

  20. Comparison of blood specimens from plain and gel vacuum blood collection tubes.

    PubMed

    Wiwanitkit, V

    2001-05-01

    This study was set in the Division of Laboratory Medicine, Chulalongkorn Hospital. All 2,000 blood specimens were randomly collected using evacuated blood collection by plain or gel vacuum tubes. After collection, each specimen was considered and judged using criteria of specimen rejection to determine how proper the specimen presentations were. All data were reviewed, collected and interpreted. It revealed that there were only 20 (1%) improper specimens and all were improper in quality. There was no significant difference between the ratio of improper specimens in both groups (P > 0.30). From this study, it revealed that efficacy of both types of vacuum tubes was not different. The new gel vacuum tube seems to be an effective tool in the evacuated blood collection system due to its advantage in reduction of time in specimen processing.

  1. Selective reinnervation: a comparison of recovery following microsuture and conduit nerve repair.

    PubMed

    Evans, P J; Bain, J R; Mackinnon, S E; Makino, A P; Hunter, D A

    1991-09-20

    Selective reinnervation was studied by comparing the regeneration across a conventional neurorraphy versus a conduit nerve repair. Lewis rats underwent right sciatic nerve transection followed by one of four different nerve repairs (n = 8/group). In groups I and II a conventional neurorraphy was performed and in groups III and IV the proximal and distal stumps were coapted by use of a silicone conduit with an interstump gap of 5 mm. The proximal and distal stumps in groups I and III were aligned anatomically correct and the proximal stump was rotated 180 degrees in groups II and IV (i.e. proximal peroneal nerve opposite the distal tibial nerve and the proximal tibial nerve opposite the distal peroneal nerve). By 14 weeks, there was an equivalent, but incomplete return in sciatic function index (SFI) in groups I, III, and IV as measured by walking track analysis. However, the SFI became unmeasurable by 6 weeks in all group II animals. At 14 weeks, the percent innervation of the tibialis anterior and medial gastronemius muscles by the peroneal and tibial nerves respectively was estimated by selective compound muscle action potential amplitude recordings. When fascicular alignment was reversed, there was greater tibial (P = 0.02) and lesser peroneal (P = 0.005) innervation of the gastrocnemius muscle in the conduit (group IV) versus the neurorraphy (group II) group. This suggests that the gastrocnemius muscle may be selectively reinnervated by the tibial nerve. However, there was no evidence of selective reinnervation of the tibialis anterior muscle. Despite these differences, the functional recovery in both conduit repair groups (III and IV) was equivalent to a correctly aligned microsuture repair (group I) and superior to that in the incorrectly aligned microsuture repair (group II).

  2. Does Instructional Alignment Matter?: Effects on Struggling Second Graders' Reading Achievement

    ERIC Educational Resources Information Center

    Wonder-McDowell, Carla; Reutzel, D. Ray; Smith, John A.

    2011-01-01

    The purpose of this study was to explore the effects of aligning classroom core reading instruction with the supplementary reading instruction provided to 133 struggling grade 2 readers. A 2-group, pre-posttest true experimental design was employed in this study. In 11 elementary schools, 12 teachers taught both the aligned and unaligned core and…

  3. Higgs boson as a top-mode pseudo-Nambu-Goldstone boson

    NASA Astrophysics Data System (ADS)

    Fukano, Hidenori S.; Kurachi, Masafumi; Matsuzaki, Shinya; Yamawaki, Koichi

    2014-09-01

    In the spirit of the top-quark condensation, we propose a model which has a naturally light composite Higgs boson, "tHiggs" (ht0), to be identified with the 126 GeV Higgs discovered at the LHC. The tHiggs, a bound state of the top quark and its flavor (vectorlike) partner, emerges as a pseudo-Nambu-Goldstone boson (NGB), "top-mode pseudo-Nambu-Goldstone boson," together with the exact NGBs to be absorbed into the W and Z bosons as well as another (heavier) top-mode pseudo-Nambu-Goldstone bosons (CP-odd composite scalar, At0). Those five composite (exact/pseudo-) NGBs are dynamically produced simultaneously by a single supercritical four-fermion interaction having U(3)×U(1) symmetry which includes the electroweak symmetry, where the vacuum is aligned by a small explicit breaking term so as to break the symmetry down to a subgroup, U(2)×U(1)', in a way not to retain the electroweak symmetry, in sharp contrast to the little Higgs models. The explicit breaking term for the vacuum alignment gives rise to a mass of the tHiggs, which is protected by the symmetry and hence naturally controlled against radiative corrections. Realistic top-quark mass is easily realized similarly to the top-seesaw mechanism by introducing an extra (subcritical) four-fermion coupling which explicitly breaks the residual U(2)'×U(1)' symmetry with U(2)' being an extra symmetry besides the above U(3)L×U(1). We present a phenomenological Lagrangian of the top-mode pseudo-Nambu-Goldstone bosons along with the Standard Model particles, which will be useful for the study of the collider phenomenology. The coupling property of the tHiggs is shown to be consistent with the currently available data reported from the LHC. Several phenomenological consequences and constraints from experiments are also addressed.

  4. Structural analysis of polymer thin films using GISAXS in the tender X-ray region: Concept and design of GISAXS experiments using the tender X-ray energy at BL-15A2 at the Photon Factory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takagi, H., E-mail: takagih@post.kek.jp; Igarashi, N.; Mori, T.

    If small angle X-ray scattering (SAXS) utilizing the soft X-ray region is available, advanced and unique experiments, which differ from traditional SAXS methods, can be realized. For example, grazing-incidence small angle X-ray scattering (GISAXS) using hard X-ray is a powerful tool for understanding the nanostructure in both vertical and lateral directions of thin films, while GISAXS utilizing the tender X-ray region (SX-GISAXS) enables depth-resolved analysis as well as a standard GISAXS analysis in thin films. Thus, at BL-15A2 at the Photon Factory, a dedicated diffractometer for SX-GISAXS (above 2.1 keV) was constructed. This diffractometer is composed of four vacuum chambers andmore » can be converted into the vacuum state from the sample chamber in front of the detector surface. Diffractions are clearly observed until 12th peak when measuring collagen by SAXS with an X-ray energy of 2.40 keV and a camera length of 825 mm. Additionally, we conducted the model experiment using SX-GISAXS with an X-ray energy of 2.40 keV to confirm that a poly(methyl methacrylate)-poly(n-butyl acrylate) block copolymer thin film has a microphase-separated structure in the thin film, which is composed of lamellae aligned both parallel and perpendicular to the substrate surface. Similarly, in a polystyrene-poly(methyl methacrylate) block copolymer thin film, SX-GISAXS with 3.60 keV and 5.73 keV revealed that hexagonally packed cylinders are aligned parallel to the substrate surface. The incident angle dependence of the first order peak position of the q{sub z} direction obtained from experiments at various incident X-ray energies agrees very well with the theoretical one calculated from the distorted wave Born approximation.« less

  5. An air-pressure-free elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis

    NASA Astrophysics Data System (ADS)

    Jung, Wooseok; Barrett, Matthew; Brooks, Carla; Rivera, Andrew; Birdsell, Dawn N.; Wagner, David M.; Zenhausern, Frederic

    2015-12-01

    We present a new elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis. The valve functions include metering to capture a designated volume of biological sample into a polymerase chain reaction (PCR) chamber, sealing to preserve the sample during PCR cycling, and transfer of the PCR-products and on-chip formamide post-processing for the analysis of DNA fragments by capillary gel electrophoresis. This new valve differs from prior art polydimethylsiloxane (PDMS) valves in that the valve is not actuated externally by air-pressure or vacuum so that it simplifies a DNA analysis system by eliminating the need for an air-pressure or vacuum source, and off-cartridge solenoid valves, control circuit boards and software. Instead, the new valve is actuated by a thermal cycling peltier assembly integrated within the hardware instrument that tightly comes in contact with a microfluidic cartridge for thermal activation during PCR, so that it spontaneously closes the valve without an additional actuator system. The valve has bumps in the designated locations so that it has a self-alignment that does not require precise alignment of a valve actuator. Moreover, the thickness of the new valve is around 600 μm with an additional bump height of 400 μm so that it is easy to handle and very feasible to fabricate by injection molding compared to other PDMS valves whose thicknesses are around 30-100 μm. The new valve provided over 95% of metering performance in filling the fixed volume of the PCR chamber, preserved over 97% of the sample volume during PCR, and showed very comparable capillary electrophoresis peak heights to the benchtop assay tube controls with very consistent transfer volume of the PCR-product and on-chip formamide. The new valve can perform a core function for integrated nucleic acid analysis by capillary electrophoresis.

  6. Mechanism of cell alignment in groups of Myxococcus xanthus bacteria

    NASA Astrophysics Data System (ADS)

    Balgam, Rajesh; Igoshin, Oleg

    2015-03-01

    Myxococcus xanthus is a model for studying self-organization in bacteria. These flexible cylindrical bacteria move along. In groups, M. xanthus cells align themselves into dynamic cell clusters but the mechanism underlying their formation is unknown. It has been shown that steric interactions can cause alignment in self-propelled hard rods but it is not clear how flexibility and reversals affect the alignment and cluster formation. We have investigated cell alignment process using our biophysical model of M. xanthus cell in an agent-based simulation framework under realistic cell flexibility values. We observed that flexible model cells can form aligned cell clusters when reversals are suppressed but these clusters disappeared when reversals frequency becomes similar to the observed value. However, M. xanthus cells follow slime (polysaccharide gel like material) trails left by other cells and we show that implementing this into our model rescues cell clustering for reversing cells. Our results show that slime following along with periodic cell reversals act as positive feedback to reinforce existing slime trails and recruit more cells. Furthermore, we have observed that mechanical cell alignment combined with slime following is sufficient to explain the distinct clustering patterns of reversing and non-reversing cells as observed in recent experiments. This work is supported by NSF MCB 0845919 and 1411780.

  7. Which Q-analogue of the squeezed oscillator?

    NASA Technical Reports Server (NTRS)

    Solomon, Allan I.

    1993-01-01

    The noise (variance squared) of a component of the electromagnetic field - considered as a quantum oscillator - in the vacuum is equal to one half, in appropriate units (taking Planck's constant and the mass and frequency of the oscillator all equal to 1). A practical definition of a squeezed state is one for which the noise is less than the vacuum value - and the amount of squeezing is determined by the appropriate ratio. Thus the usual coherent (Glauber) states are not squeezed, as they produce the same variance as the vacuum. However, it is not difficult to define states analogous to coherent states which do have this noise-reducing effect. In fact, they are coherent states in the more general group sense but with respect to groups other than the Heisenberg-Weyl Group which defines the Glauber states. The original, conventional squeezed state in quantum optics is that associated with the group SU(1,1). Just as the annihilation operator a of a single photon mode (and its hermitian conjugate a, the creation operator) generates the Heisenberg Weyl algebra, so the pair-photon operator a(sup 2) and its conjugate generates the algebra of the group SU(1,1). Another viewpoint, more productive from the calculational stance, is to note that the automorphism group of the Heisenberg-Weyl algebra is SU(1,1). Needless to say, each of these viewpoints generalizes differently to the quantum group context. Both are discussed. The following topics are addressed: conventional coherent and squeezed states; eigenstate definitions; exponential definitions; algebra (group) definitions; automorphism group definition; example: signal-to-noise ratio; q-coherent and q-squeezed states; M and P q-bosons; eigenstate definitions; exponential definitions; algebra (q-group) definitions; and automorphism q-group definition.

  8. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial.

    PubMed

    Kosse, Nienke M; Heesterbeek, Petra J C; Schimmel, Janneke J P; van Hellemondt, Gijs G; Wymenga, Ate B; Defoort, Koen C

    2018-06-01

    The primary aim of the study was to examine stability and alignment after total knee arthroplasty (TKA) using patient-specific instrumentation (PSI) and conventional instrumentation (CI). The hypothesis was that stability and alignment would be better using PSI than CI, 12 months postoperatively. The secondary aim included the evaluation of clinical outcomes after TKA. In this prospective randomized controlled trial, 42 patients with knee osteoarthritis received a Genesis II PS prosthesis with either PSI or CI. Patients visited the hospital preoperatively and postoperatively after 6 weeks and 3 and 12 months. To evaluate stability, varus-valgus laxity was determined in extension and flexion using stress radiographs 12 months postoperatively. Three months postoperatively, a long-leg radiograph and CT scan were obtained to measure hip-knee-ankle (HKA) alignment and component rotation. Furthermore, frontal and sagittal alignment of the components, the Knee Society Score, VAS Pain, VAS Satisfaction, Knee injury and Osteoarthritis Outcome score, Patella score (Kujala), University of California Los Angeles activity score, anterior-posterior laxity, (serious) adverse device-related events, and intraoperative complications were reported. The clinical outcomes were compared using independent t tests or non-parametric alternatives, and repeated measurements ANOVA with a significance level of p < 0.05. No significant differences were found between the two groups regarding stability, HKA angle, and rotational alignment. In four patients, the PSI did not fit correctly on the tibia and/or femur requiring intraoperative modifications. Both groups improved significantly over time on all clinical outcomes, with no significant differences between the groups 12 months postoperatively. The PSI group showed less tibial slope than the patients in the CI group [PSI 2.6° versus CI 4.8° (p = 0.02)]. Finally, the PSI group more frequently received a thinner insert size than the CI group (p = 0.03). Patients operated with PSI did not differ from CI in terms of stability and alignment. However, in the PSI group ligament releases were more often required intraoperatively. Furthermore, the two methods did not show different clinical results. It seems that the preoperative planning for the PSI facilitates more conservative bone cuts than CI, but whether this is clinically relevant should be investigated. Since PSI is more expensive and time consuming than CI, and does not outperform CI with regard to clinical results, we recommend to use CI. I.

  9. The effect of vacuum packaging, EDTA, oregano and thyme oils on the microbiological quality of chicken's breast.

    PubMed

    Pavelková, Adriana; Kačániová, Miroslava; Horská, Elena; Rovná, Katarína; Hleba, Lukáš; Petrová, Jana

    2014-10-01

    The effect of ethylenediaminetetraacetate (EDTA), oregano (Origanum vulgare) and thyme (Thymus vulgaris) oils, on the chicken breast fillets was examined in this study. The chicken breast fillets were stored under vacuum packaging (VP), at 4 ± 0.5 °C for a period of 18 days. There were used the following treatments of chicken breast fillets: Air-packaged (AC, control samples), vacuum-packaged (VPC, control samples), VP with EDTA solution 1.50% w/w (VPEC, control samples), VP with oregano oil 0.20% v/w (VP + O) and VP with thyme oil 0.20% v/w, (VP + T). The quality assessment for vacuum packaging of the product in accordance with the terms above and EDTA treatment, oregano and thyme oil was established by microbiological analyzes. The microbiological properties as the total viable counts on Plate Count Agar, after incubation for 2 days at 37 °C and coliform bacteria on Violet Red Bile Glucose agar incubated at 37 °C for 24 h, lactobacilli on Rogosa and Sharpe agar after incubation 48-78 h at 37 °C in an aerobic atmosphere supplemented with carbon dioxide (5% CO2) and Pseudomonas aeruginosa on Pseudomonas Isolation agar (PIA, Oxoid, UK) after incubation at 48 h at 35 °C were monitored. The using of oregano, thyme oil and EDTA with combination of vacuum packaging has significant effects to reduction of all followed groups of microorganisms compared with control group without vacuum packaging and untreated control group. The natural preservatives can be used as alternatives to chemical additives which could extend the meat and meat products shelf life. The knowledge about them can have an important economic feedback by reducing losses attributed to spoilage and by allowing the products to reach distant and new markets. This study shows how using of natural antimicrobials can extend the shelf-life of the meat product. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling

    PubMed Central

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J.; Martin, James C.; Crouter, Scott E.; Fitzhugh, Eugene C.

    2018-01-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling. Key points Varus or valgus alignment did not cause increased frontal-plane knee joint loading, suggesting stationary cycling is a safe exercise. This study supports that using a toe clip did not lead to abnormal frontal-plane knee loading during stationary cycling. Two different knee frontal plane loading patterns, knee abduction and adduction moment, were observed during stationary cycling, which are likely affected by the type of knee alignment. PMID:29769833

  11. Structure and Characterization of Vertically Aligned Single-Walled Carbon Nanotube Bundles

    DOE PAGES

    Márquez, Francisco; López, Vicente; Morant, Carmen; ...

    2010-01-01

    Arrmore » ays of vertically aligned single-walled carbon nanotube bundles, SWCNTs, have been synthesized by simple alcohol catalytic chemical vapor deposition process, carried out at 800 ° C . The formed SWCNTs are organized in small groups perpendicularly aligned and attached to the substrate. These small bundles show a constant diameter of ca. 30 nm and are formed by the adhesion of no more than twenty individual SWCNTs perfectly aligned along their length.« less

  12. Holistic face perception is modulated by experience-dependent perceptual grouping.

    PubMed

    Curby, Kim M; Entenman, Robert J; Fleming, Justin T

    2016-07-01

    What role do general-purpose, experience-sensitive perceptual mechanisms play in producing characteristic features of face perception? We previously demonstrated that different-colored, misaligned framing backgrounds, designed to disrupt perceptual grouping of face parts appearing upon them, disrupt holistic face perception. In the current experiments, a similar part-judgment task with composite faces was performed: face parts appeared in either misaligned, different-colored rectangles or aligned, same-colored rectangles. To investigate whether experience can shape impacts of perceptual grouping on holistic face perception, a pre-task fostered the perception of either (a) the misaligned, differently colored rectangle frames as parts of a single, multicolored polygon or (b) the aligned, same-colored rectangle frames as a single square shape. Faces appearing in the misaligned, differently colored rectangles were processed more holistically by those in the polygon-, compared with the square-, pre-task group. Holistic effects for faces appearing in aligned, same-colored rectangles showed the opposite pattern. Experiment 2, which included a pre-task condition fostering the perception of the aligned, same-colored frames as pairs of independent rectangles, provided converging evidence that experience can modulate impacts of perceptual grouping on holistic face perception. These results are surprising given the proposed impenetrability of holistic face perception and provide insights into the elusive mechanisms underlying holistic perception.

  13. Cosmological constant problem and renormalized vacuum energy density in curved background

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohri, Kazunori; Matsui, Hiroki, E-mail: kohri@post.kek.jp, E-mail: matshiro@post.kek.jp

    The current vacuum energy density observed as dark energy ρ{sub dark}≅ 2.5×10{sup −47} GeV{sup 4} is unacceptably small compared with any other scales. Therefore, we encounter serious fine-tuning problem and theoretical difficulty to derive the dark energy. However, the theoretically attractive scenario has been proposed and discussed in literature: in terms of the renormalization-group (RG) running of the cosmological constant, the vacuum energy density can be expressed as ρ{sub vacuum}≅ m {sup 2} H {sup 2} where m is the mass of the scalar field and rather dynamical in curved spacetime. However, there has been no rigorous proof to derivemore » this expression and there are some criticisms about the physical interpretation of the RG running cosmological constant. In the present paper, we revisit the RG running effects of the cosmological constant and investigate the renormalized vacuum energy density in curved spacetime. We demonstrate that the vacuum energy density described by ρ{sub vacuum}≅ m {sup 2} H {sup 2} appears as quantum effects of the curved background rather than the running effects of cosmological constant. Comparing to cosmological observational data, we obtain an upper bound on the mass of the scalar fields to be smaller than the Planck mass, m ∼< M {sub Pl}.« less

  14. Classification of high-grade spondylolistheses based on pelvic version and spine balance: possible rationale for reduction.

    PubMed

    Hresko, Michael T; Labelle, Hubert; Roussouly, Pierre; Berthonnaud, Eric

    2007-09-15

    Retrospective review of a radiographic database of high-grade spondylolisthesis patients in comparison with asymptomatic controls. To analyze the sagittal spinopelvic alignment in high-grade spondylolisthesis patients and identify subgroups that may require reduction to restore sagittal balance. High-grade spondylolisthesis is associated with an abnormally high pelvic incidence (PI); however, the spatial orientation of the pelvis, determined by sacral slope (SS) and pelvic tilt (PT), is not known. We hypothesized that sagittal spinal alignment would vary with the pelvic orientation. Digitized sagittal radiographs of 133 high-grade spondylolisthesis patients (mean age, 17 years) were measured to determined sagittal alignment. K-means cluster analysis identified 2 groups based on the PT and SS, which were compared by paired t test. Comparisons were made to asymptomatic controls matched for PI. High-grade spondylolisthesis patients had a mean PI of 78.9 degrees +/- 12.1 degrees . Cluster analysis identified a retroverted, unbalanced pelvis group with high PT (36.5 degrees +/- 8.0 degrees )/low SS (40.3 degrees +/- 9.0 degrees ) and a balanced pelvic group with low PT (mean 21.3 degrees +/- 8.2 degrees )/high SS (59.9 degrees +/- 11.2 degrees ). The retroverted pelvis group had significantly greater L5 incidence and lumbosacral angle with less thoracic kyphosis than the balanced pelvic group. A total of 83% of controls had a "balanced pelvis" based on the categorization by SS and PT. Analysis of sagittal alignment of high-grade spondylolisthesis patients revealed distinct groups termed "balanced" and "unbalanced" pelvis. The PT and SS were similar in controls and balanced pelvis patients. Unbalanced pelvis patients had a sagittal spinal alignment that differed from the balanced pelvis and control groups. Treatment strategies for high-grade spondylolisthesis should reflect the different mechanical strain on the spinopelvic junction in each group; reduction techniques might be considered in patients with an unbalanced pelvis high-grade spondylolisthesis.

  15. Comparison of single-incision mini-slings (Ajust) and standard transobturator midurethral slings (Align) in the management of female stress urinary incontinence: A 1-year follow-up.

    PubMed

    Chang, Chia-Pei; Chang, Wen-Hsun; Hsu, Yen-Mei; Chen, Yi-Jen; Wen, Kuo-Chang; Chao, Kuan-Chong; Yen, Ming-Shyen; Horng, Huann-Cheng; Wang, Peng-Hui

    2015-12-01

    To investigate the effectiveness and safety of a new single-incision mini-sling (SIMS)-Ajust-compared with the standard transobturator midurethral sling (SMUS)-Align-for the treatment of female stress urinary incontinence (SUI). A retrospective cohort study was conducted between January 1, 2010 and August 31, 2012. Women with SUI who underwent either SMUS-Align or SIMS-Ajust were recruited. The primary outcomes included operation time, estimated operative blood loss, postoperative pain, and complications. The secondary outcomes included subjective and objective success, defined as an International Consultation on Incontinence Questionnaire (ICIQ) score of 0 or improvement as felt by the patient and a long-term complication, such as dyspareunia and mesh erosion after 6 months and 12 months of follow-up. A total of 136 patients were enrolled, including 76 receiving SMUS-Align and 60 receiving SIMS-Ajust. Baseline characteristics of the patients in both groups were similar, without a statistically significant difference. Primary outcomes between both groups were similar, except that women treated with SIMS-Ajust had statistically significantly shorter operation time (p = 0.003), less intent to treat (p < 0.05), and earlier postoperative discharge (p = 0.001) than women treated with SMUS-Align. Secondary outcomes were similar without a significant difference between the two groups (93% vs. 88% success rate in each group). Our results showed that SIMS-Ajust was not inferior to SMUS-Align with respect to success rate, and might have a slight advantage in early discharge. A long-term follow-up or prospective study is needed to confirm the above findings. Copyright © 2015. Published by Elsevier B.V.

  16. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling.

    PubMed

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J; Martin, James C; Crouter, Scott E; Fitzhugh, Eugene C

    2018-06-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling.

  17. Effective allergen avoidance for reducing exposure to house dust mite allergens and improving disease management in adult atopic asthmatics.

    PubMed

    Tsurikisawa, Naomi; Saito, Akemi; Oshikata, Chiyako; Yasueda, Hiroshi; Akiyama, Kazuo

    2016-10-01

    We investigated the best strategy for adult asthmatics to avoid exposure to Dermatophagoides group (Der-1) allergens. Adult atopic asthmatics (n = 111) followed a 32-item checklist for avoiding Der-1 allergen exposure. Twenty-five patients were excluded through incomplete sampling; 50 remaining patients encased their pillows/futons/mattresses in microfine-fiber covers, 13 used vacuum cleaners with dust-mite-collection nozzles, and 23 acted as non-intervention controls. During August-October 2010 and August-October 2011, dust samples were collected in Petri dishes placed in bedrooms for 2 weeks and from mattresses/futons by using adhesive tape on one morning. A Der-1 level decrease was defined as a mean 2011 Der-1 level of <1 as a ratio of the 2010 level on tape or Petri dish samples. We analyzed the associations between Der-1 level change (by ELISA) and % weekly variability in peak expiratory flow (PEF) or fraction of exhaled nitric oxide (FeNO) after intervention. Der-1 levels decreased significantly in the covers group but not the vacuuming group. FeNO levels and PEF variability were unchanged in both groups. In patients whose Petri dish or tape samples showed decreased Der-1 levels, the % PEF variability was lower in 2011 than in 2010, but FeNO levels were unchanged. Three interventions (vacuuming all family members' mattress/futon surfaces at least weekly or after exposure of the futons to sunlight, and floor wiping before vacuuming), plus using covers, were the most effective management strategy in reducing Der-1 levels. This environmental and bedding maintenance program may help manage adult atopic asthma.

  18. Rapid vacuum sintering: A novel technique for fabricating fluorapatite ceramic scaffolds for bone tissue engineering.

    PubMed

    Denry, Isabelle; Goudouri, Ourania-Menti; Harless, Jeffrey; Holloway, Julie A

    2018-01-01

    Macroporous bioceramic scaffolds are often fabricated via the foam replica technique, based on polymeric foam impregnation with a glass slurry, followed by slow heat treatment to allow for drying, polymeric burnout, and sintering of the glass particles. As a consequence, the process is time consuming and complicated by concurrent crystallization of the glass, often leading to incomplete sintering. Our goal was to investigate the effect of heating rate on sintering behavior, architecture, and mechanical properties of fluorapatite-based glass and glass-ceramic scaffolds. Glass scaffolds were prepared and sintered by rapid vacuum sintering (RVS) at 785°C under vacuum at a fast heating rate (55°C/min.) or without vacuum at a slow heating rate (2°C/min.). Two additional groups were further crystallized at 775°C/1 h. XRD confirmed the presence of fluorapatite for crystallized scaffolds. All groups presented interconnected porosity with a pore size in the 500 μm range. Scaffolds produced by RVS exhibited an excellent degree of sintering while scaffolds produced by slow sintering were incompletely sintered. The mean compressive strength was significantly higher for the RVS groups (1.52 ± 0.55 and 1.72 ± 0.61 MPa) compared to the slow-sintered groups (0.54 ± 0.30 and 0.45 ± 0.26 MPa). Meanwhile, the total production time was reduced by more than 12 h by using the RVS technique. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 291-299, 2018. © 2017 Wiley Periodicals, Inc.

  19. Entangled time in flocking: Multi-time-scale interaction reveals emergence of inherent noise

    PubMed Central

    Murakami, Hisashi

    2018-01-01

    Collective behaviors that seem highly ordered and result in collective alignment, such as schooling by fish and flocking by birds, arise from seamless shuffling (such as super-diffusion) and bustling inside groups (such as Lévy walks). However, such noisy behavior inside groups appears to preclude the collective behavior: intuitively, we expect that noisy behavior would lead to the group being destabilized and broken into small sub groups, and high alignment seems to preclude shuffling of neighbors. Although statistical modeling approaches with extrinsic noise, such as the maximum entropy approach, have provided some reasonable descriptions, they ignore the cognitive perspective of the individuals. In this paper, we try to explain how the group tendency, that is, high alignment, and highly noisy individual behavior can coexist in a single framework. The key aspect of our approach is multi-time-scale interaction emerging from the existence of an interaction radius that reflects short-term and long-term predictions. This multi-time-scale interaction is a natural extension of the attraction and alignment concept in many flocking models. When we apply this method in a two-dimensional model, various flocking behaviors, such as swarming, milling, and schooling, emerge. The approach also explains the appearance of super-diffusion, the Lévy walk in groups, and local equilibria. At the end of this paper, we discuss future developments, including extending our model to three dimensions. PMID:29689074

  20. Starting from the Classroom: How an Inter-Segmental Faculty Group Works toward Increased K-16 Alignment

    ERIC Educational Resources Information Center

    De Roy, Tessa Carmen

    2011-01-01

    There is a lack of alignment between K-12 and higher education about the expectations for student skill and content knowledge. Too often, students leave the K-12 system ill prepared for success in higher education. One approach to increasing alignment has been supported by the California Partnership for Achieving Student Success (Cal-PASS), which…

  1. Construction, characterization, and environmental testing of a Laue lens prototype using Fe and Al crystals

    NASA Astrophysics Data System (ADS)

    Wade, C.; Barrière, N. M.; Tomsick, J. A.; Hanlon, L.; Boggs, S. E.; Lowell, A.; von Ballmoos, P.; Massahi, S.

    2018-07-01

    Laue lenses use Bragg diffraction to concentrate soft γ-rays onto a detector. This decoupling of the collecting area from the detector volume can generate a significant increase in sensitivity for applications in astrophysics and nuclear medicine. A demonstrator lens was constructed at the UC Berkeley's Space Sciences Laboratory in 2014 by gluing 48 Fe and Al diffracting crystals to an aluminium substrate. The goal was to demonstrate a fast and accurate assembly technique that is compatible with the large number of crystals required to fabricate a Laue lens telescope for astronomical observations. We present here the lens design, the assembly technique we used, and the results of measurements of the angular misalignments before and after curing of the glue and during environmental testing (thermal, vacuum, and vibration). We conclude that our alignment technique is fast enough to assemble a full lens made of several thousand crystals. The achieved alignment accuracy had an average of 32.7‧‧ and a standard deviation of 44.1‧‧. The accuracy could be improved by using an alternative glue or by having better control over the asymmetry angle resulting from the crystal cut.

  2. Self aligning electron beam gun having enhanced thermal and mechanical stability

    DOEpatents

    Scarpetti, R.D. Jr.; Parkison, C.D.; Switzer, V.A.; Lee, Y.J.; Sawyer, W.C.

    1995-05-16

    A compact, high power electron gun is disclosed having enhanced thermal and mechanical stability which incorporates a mechanically coupled, self aligning structure for the anode and cathode. The enhanced stability, and reduced need for realignment of the cathode to the anode and downstream optics during operation are achieved by use of a common support structure for the cathode and anode which requires no adjustment screws or spacers. The electron gun of the present invention also incorporates a modular design for the cathode, in which the electron emitter, its support structure, and the hardware required to attach the emitter assembly to the rest of the gun are a single element. This modular design makes replacement of the emitter simpler and requires no realignment after a new emitter has been installed. Compactness and a reduction in the possibility of high voltage breakdown are achieved by shielding the ``triple point`` where the electrode, insulator, and vacuum meet. The use of electric discharge machining (EDM) for fabricating the emitter allows for the accurate machining of the emitter into intricate shapes without encountering the normal stresses developed by standard emitter fabrication techniques. 12 Figs.

  3. Effect of shoulder girdle strengthening on trunk alignment in patients with stroke.

    PubMed

    Awad, Amina; Shaker, Hussien; Shendy, Wael; Fahmy, Manal

    2015-07-01

    [Purpose] This study investigated the effect of shoulder girdle strengthening, particularly the scapular muscles, on poststroke trunk alignment. [Subjects and Methods] The study involved 30 patients with residual hemiparesis following cerebrovascular stroke. Patient assessment included measuring shoulder muscle peak torque, scapular muscles peak force, spinal lateral deviation angle, and motor functional performance. Patients were randomly allocated either to the control group or the study group and received an 18-session strengthening program including active resisted exercises for shoulder abductors and external rotators in addition to trunk control exercises. The study group received additional strengthening exercises for the scapular muscles. [Results] The two groups showed significant improvement in strength of all shoulder and scapular muscles, with higher improvement in the study group. Similarly, the lateral spinal deviation angles significantly improved in both groups, with significantly higher improvement in the study group. Transfer activity, sitting balance, upper limb functions, and hand movements significantly improved in the two groups, with higher improvement in the latter two functions in the study group. [Conclusion] Strengthening of shoulder girdle muscles, particularly scapular muscles, can significantly contribute to improving the postural alignment of the trunk in patients with poststroke hemiparesis.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roy, Amitava; Harilal, Sivanandan S.; Hassan, Syed M.

    We investigated the expansion dynamics of laser-produced plasmas expanding into an axial magnetic field. Plasmas were generated by focusing 1.064 µm Nd:YAG laser pulses onto a planar tin target in vacuum and allowed to expand into a 0.5 T magnetic-filed where field lines were aligned along the plume expansion direction. Gated images employing intensified CCD showed focusing of the plasma plume, which were also compared with results obtained using particle-in-cell modelling methods. The estimated density and temperature of the plasma plumes employing emission spectroscopy revealed significant changes in the presence and absence of the 0.5T magnetic field. In the presencemore » of the field, the electron temperature is increased with distance from the target, while the density showed opposite effects.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    RAKOWKSY,G.; ASPENLEITER,J.; SOLOMON,L.

    The Visible-Infrared SASE Amplifier (VISA) undulator is an in-vacuum, 4-meter long, 1.8 cm period, pure-permanent magnet device, with a novel, strong focusing, permanent magnet FODO array included within the fixed, 6 mm undulator gap. The undulator magnet is constructed of 99-cm long segments, joined into a continuous structure. To attain maximum SASE gain requites establishing overlap of electron and photon beams to within 50 microns rms. This imposes challenging tolerances on mechanical fabrication and magnetic field quality, and necessitates use of laser straightness interferometry for calibration and alignment of the magnetic axes of the undulator segments. This paper describes themore » computerized magnet sorting, pulsed-wire magnetic measurements, trajectory shimming and magnetic axis calibration performed to meet this goal.« less

  6. Graphene nanoplatelet composite 'paper' as an electrostatic actuator.

    PubMed

    Yu, Zeyang; Drzal, Lawrence T

    2018-08-03

    Graphene nanoplatelets (GnP) can be made into a thin 'paper' through vacuum filtration of GnP suspension. Electrodes were fabricated from the compressed GnP paper and then by coating the surface with epoxy. The electrostatic actuator was constructed from two parallel-aligned composite papers fixed at the anode and a cathode connected to ground. The two composite papers would then separate when a voltage was applied. The GnP paper was also modified to increase surface area by introducing porosity or adding ∼10 wt% C750 (GnP with diameter less than 1 μm); or changing the relative permittivity by adding barium titanate particles; or combining these two effects by adding CNCs. Overall the output work could be significantly improved to over 400%.

  7. Characterization of in-flight performance of ion propulsion systems

    NASA Astrophysics Data System (ADS)

    Sovey, James S.; Rawlin, Vincent K.

    1993-06-01

    In-flight measurements of ion propulsion performance, ground test calibrations, and diagnostic performance measurements were reviewed. It was found that accelerometers provided the most accurate in-flight thrust measurements compared with four other methods that were surveyed. An experiment has also demonstrated that pre-flight alignment of the thrust vector was sufficiently accurate so that gimbal adjustments and use of attitude control thrusters were not required to counter disturbance torques caused by thrust vector misalignment. The effects of facility background pressure, facility enhanced charge-exchange reactions, and contamination on ground-based performance measurements are also discussed. Vacuum facility pressures for inert-gas ion thruster life tests and flight qualification tests will have to be less than 2 mPa to ensure accurate performance measurements.

  8. Characterization of in-flight performance of ion propulsion systems

    NASA Technical Reports Server (NTRS)

    Sovey, James S.; Rawlin, Vincent K.

    1993-01-01

    In-flight measurements of ion propulsion performance, ground test calibrations, and diagnostic performance measurements were reviewed. It was found that accelerometers provided the most accurate in-flight thrust measurements compared with four other methods that were surveyed. An experiment has also demonstrated that pre-flight alignment of the thrust vector was sufficiently accurate so that gimbal adjustments and use of attitude control thrusters were not required to counter disturbance torques caused by thrust vector misalignment. The effects of facility background pressure, facility enhanced charge-exchange reactions, and contamination on ground-based performance measurements are also discussed. Vacuum facility pressures for inert-gas ion thruster life tests and flight qualification tests will have to be less than 2 mPa to ensure accurate performance measurements.

  9. Homeotropic alignment of multiple bent-core liquid crystal phases using a polydimethylsiloxane alignment layer

    NASA Astrophysics Data System (ADS)

    Carlson, Eric D.; Foley, Lee M.; Guzman, Edward; Korblova, Eva D.; Visvanathan, Rayshan; Ryu, SeongHo; Gim, Min-Jun; Tuchband, Michael R.; Yoon, Dong Ki; Clark, Noel A.; Walba, David M.

    2017-08-01

    The control of the molecular orientation of liquid crystals (LCs) is important in both understanding phase properties and the continuing development of new LC technologies including displays, organic transistors, and electro-optic devices. Many techniques have been developed for successfully inducing alignment of calamitic LCs, though these techniques typically do not translate to the alignment of bent-core liquid crystals (BCLCs). Some techniques have been utilized to align various phases of BCLCs, but these techniques are often unsuccessful for general alignment of multiple materials and/or multiple phases. Here, we demonstrate that glass cells treated with polydimethylsiloxane (PDMS) thin films induce high quality homeotropic alignment of multiple mesophases of four BCLCs. On cooling to the lowest temperature phase the homeotropic alignment is lost, and spherulitic growth is seen in crystal and crystal-like phases including the dark conglomerate (DC) and helical nanofilament (HNF) phases. Evidence of homeotropic alignment is observed using polarized optical microscopy. We speculate that the methyl groups on the surface of the PDMS films strongly interact with the aliphatic tails of each mesogens, resulting in homeotropic alignment.

  10. Vacuum-assisted venous return reduces blood usage.

    PubMed

    Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M

    2003-09-01

    To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased red cell and total blood product usage.

  11. Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents.

    PubMed

    Castillo-de-Oyagüe, Raquel; Sánchez-Turrión, Andrés; López-Lozano, José-Francisco; Albaladejo, Alberto; Torres-Lagares, Daniel; Montero, Javier; Suárez-García, Maria-Jesús

    2012-07-01

    This study aimed to evaluate the vertical discrepancy of implant-supported crown structures constructed with vacuum-casting and Direct Metal Laser Sintering (DMLS) technologies, and luted with different cement types. Crown copings were fabricated using: (1) direct metal laser sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC); and (3) vacuum-cast Ti (CT). Frameworks were luted onto machined implant abutments under constant seating pressure. Each alloy group was randomly divided into 5 subgroups (n = 10 each) according to the cement system utilized: Subgroup 1 (KC) used resin-modified glass-ionomer Ketac Cem Plus; Subgroup 2 (PF) used Panavia F 2.0 dual-cure resin cement; Subgroup 3 (RXU) used RelyX Unicem 2 Automix self-adhesive dual-cure resin cement; Subgroup 4 (PIC) used acrylic/urethane-based temporary Premier Implant Cement; and Subgroup 5 (DT) used acrylic/urethane-based temporary DentoTemp cement. Vertical misfit was measured by scanning electron microscopy (SEM). Two-way ANOVA and Student-Newman-Keuls tests were run to investigate the effect of alloy/fabrication technique, and cement type on vertical misfit. The statistical significance was set at α = 0.05. The alloy/manufacturing technique and the luting cement affected the vertical discrepancy (p < 0.001). For each cement type, LS samples exhibited the best fit (p < 0.01) whereas CC and CT frames were statistically similar. Within each alloy group, PF and RXU provided comparably greater discrepancies than KC, PIC, and DT, which showed no differences. Laser sintering may be an alternative to vacuum-casting of base metals to obtain passive-fitting implant-supported crown copings. The best marginal adaptation corresponded to laser sintered structures luted with glass-ionomer KC, or temporary PIC or DT cements. The highest discrepancies were recorded for Co-Cr and Ti cast frameworks bonded with PF or RXU resinous agents. All groups were within the clinically acceptable misfit range.

  12. Method of fabricating vertically aligned group III-V nanowires

    DOEpatents

    Wang, George T; Li, Qiming

    2014-11-25

    A top-down method of fabricating vertically aligned Group III-V micro- and nanowires uses a two-step etch process that adds a selective anisotropic wet etch after an initial plasma etch to remove the dry etch damage while enabling micro/nanowires with straight and smooth faceted sidewalls and controllable diameters independent of pitch. The method enables the fabrication of nanowire lasers, LEDs, and solar cells.

  13. Forces and moments generated by removable thermoplastic aligners: incisor torque, premolar derotation, and molar distalization.

    PubMed

    Simon, Mareike; Keilig, Ludger; Schwarze, Jörg; Jung, Britta A; Bourauel, Christoph

    2014-06-01

    The exact force systems as well as their progressions generated by removable thermoplastic appliances have not been investigated. Thus, the purposes of this experimental study were to quantify the forces and moments delivered by a single aligner and a series of aligners (Invisalign; Align Technology, Santa Clara, Calif) and to investigate the influence of attachments and power ridges on the force transfer. We studied 970 aligners of the Invisalign system (60 series of aligners). The aligners came from 30 consecutive patients, of which 3 tooth movements (incisor torque, premolar derotation, molar distalization) with 20 movements each were analyzed. The 3 movement groups were subdivided so that 10 movements were supported with an attachment and 10 were not. The patients' ClinCheck (Align Technology, Santa Clara, Calif) was planned so that the movements to be investigated were performed in isolation in the respective quadrant. Resin replicas of the patients' intraoral situation before the start of the investigated movement were taken and mounted in a biomechanical measurement system. An aligner was put on the model, the force systems were measured, and the calculated movements were experimentally performed until no further forces or moments were generated. Subsequently, the next aligners were installed, and the measurements were repeated. The initial mean moments were about 7.3 N·mm for maxillary incisor torque and about 1.0 N for distalization. Significant differences in the generated moments were measured in the premolar derotation group, whether they were supported with an attachment (8.8 N·mm) or not (1.2 N·mm). All measurements showed an exponential force change. Apart from a few maximal initial force systems, the forces and moments generated by aligners of the Invisalign system are within the range of orthodontic forces. The force change is exponential while a patient is wearing removable thermoplastic appliances. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  14. Strain activation of bovine aortic smooth muscle cell proliferation and alignment: study of strain dependency and the role of protein kinase A and C signaling pathways

    NASA Technical Reports Server (NTRS)

    Mills, I.; Cohen, C. R.; Kamal, K.; Li, G.; Shin, T.; Du, W.; Sumpio, B. E.

    1997-01-01

    Smooth muscle cell (SMC) phenotype can be altered by physical forces as demonstrated by cyclic strain-induced changes in proliferation, orientation, and secretion of macromolecules. However, the magnitude of strain required and the intracellular coupling pathways remain ill defined. To examine the strain requirements for SMC proliferation, we selectively seeded bovine aortic SMC either on the center or periphery of silastic membranes which were deformed with 150 mm Hg vacuum (0-7% center; 7-24% periphery). SMC located in either the center or peripheral regions showed enhanced proliferation compared to cells grown under the absence of cyclic strain. Moreover, SMC located in the center region demonstrated significantly (P < 0.005) greater proliferation as compared to those in the periphery. In contrast, SMC exposed to high strain (7-24%) demonstrated alignment perpendicular to the strain gradient, whereas SMC in the center (0-7%) remained aligned randomly. To determine the mechanisms of these phenomena, we examined the effect of cyclic strain on bovine aortic SMC signaling pathways. We observed strain-induced stimulation of the cyclic AMP pathway including adenylate cyclase activity and cyclic AMP accumulation. In addition, exposure of SMC to cyclic strain caused a significant increase in protein kinase C (PKC) activity and enzyme translocation from the cytosol to a particulate fraction. Further study was conducted to examine the effect of strain magnitude on signaling, particularly protein kinase A (PKA) activity as well as cAMP response element (CRE) binding protein levels. We observed significantly (P < 0.05) greater PKA activity and CRE binding protein levels in SMC located in the center as compared to the peripheral region. However, inhibition of PKA (with 10 microM Rp-cAMP) or PKC (with 5-20 ng/ml staurosporine) failed to alter either the strain-induced increase in SMC proliferation or alignment. These data characterize the strain determinants for activation of SMC proliferation and alignment. Although strain activated both the AC/cAMP/PKA and the PKC pathways in SMC, singular inhibition of PKA and PKC failed to prevent strain-induced alignment and proliferation, suggesting either their lack of involvement or the multifactorial nature of these responses.

  15. Aligning Curriculum Materials with the Australian Curriculum: What Is Happening in the Field and What Needs to Be Done?

    ERIC Educational Resources Information Center

    Watt, Michael

    2016-01-01

    The purpose of this study was to inform the deliberations of a policymakers' working group by investigating what key actors in the materials' marketplace are doing to align digital and print-based materials with the Australian Curriculum and what steps need to be taken to deliver aligned materials to schools. Content analysis method was used to…

  16. Effect of Capacitive and Resistive electric transfer on changes in muscle flexibility and lumbopelvic alignment after fatiguing exercise.

    PubMed

    Yokota, Yuki; Sonoda, Takuya; Tashiro, Yuto; Suzuki, Yusuke; Kajiwara, Yu; Zeidan, Hala; Nakayama, Yasuaki; Kawagoe, Mirei; Shimoura, Kanako; Tatsumi, Masataka; Nakai, Kengo; Nishida, Yuichi; Bito, Tsubasa; Yoshimi, Soyoka; Aoyama, Tomoki

    2018-05-01

    [Purpose] This study aimed to clarify the effects of Capacitive and Resistive electric transfer (CRet) on changes in muscle flexibility and lumbopelvic alignment after fatiguing exercise. [Subjects and Methods] Twenty-two healthy males were assigned into either the CRet (n=11) or control (n=11) group. Fatiguing exercise and CRet intervention were applied at the quadriceps muscle of the participants' dominant legs. The Ely test, pelvic tilt, lumbar lordosis, and superficial temperature were measured before and after exercise and for 30 minutes after intervention. Statistical analysis was performed using one-way analysis of variance, with Tukey's post-hoc multiple comparison test to clarify within-group changes and Student's t-test to clarify between-group differences. [Results] The Ely test and pelvic tilt were significantly different in both groups after exercise, but there was no difference in the CRet group after intervention. Superficial temperature significantly increased in the CRet group for 30 minutes after intervention, in contrast to after the exercise and intervention in the control group. There was no significant between-group difference at any timepoint, except in superficial temperature. [Conclusion] CRet could effectively improve muscle flexibility and lumbopelvic alignment after fatiguing exercise.

  17. Effect of Capacitive and Resistive electric transfer on changes in muscle flexibility and lumbopelvic alignment after fatiguing exercise

    PubMed Central

    Yokota, Yuki; Sonoda, Takuya; Tashiro, Yuto; Suzuki, Yusuke; Kajiwara, Yu; Zeidan, Hala; Nakayama, Yasuaki; Kawagoe, Mirei; Shimoura, Kanako; Tatsumi, Masataka; Nakai, Kengo; Nishida, Yuichi; Bito, Tsubasa; Yoshimi, Soyoka; Aoyama, Tomoki

    2018-01-01

    [Purpose] This study aimed to clarify the effects of Capacitive and Resistive electric transfer (CRet) on changes in muscle flexibility and lumbopelvic alignment after fatiguing exercise. [Subjects and Methods] Twenty-two healthy males were assigned into either the CRet (n=11) or control (n=11) group. Fatiguing exercise and CRet intervention were applied at the quadriceps muscle of the participants’ dominant legs. The Ely test, pelvic tilt, lumbar lordosis, and superficial temperature were measured before and after exercise and for 30 minutes after intervention. Statistical analysis was performed using one-way analysis of variance, with Tukey’s post-hoc multiple comparison test to clarify within-group changes and Student’s t-test to clarify between-group differences. [Results] The Ely test and pelvic tilt were significantly different in both groups after exercise, but there was no difference in the CRet group after intervention. Superficial temperature significantly increased in the CRet group for 30 minutes after intervention, in contrast to after the exercise and intervention in the control group. There was no significant between-group difference at any timepoint, except in superficial temperature. [Conclusion] CRet could effectively improve muscle flexibility and lumbopelvic alignment after fatiguing exercise. PMID:29765189

  18. An integrated workflow for robust alignment and simplified quantitative analysis of NMR spectrometry data.

    PubMed

    Vu, Trung N; Valkenborg, Dirk; Smets, Koen; Verwaest, Kim A; Dommisse, Roger; Lemière, Filip; Verschoren, Alain; Goethals, Bart; Laukens, Kris

    2011-10-20

    Nuclear magnetic resonance spectroscopy (NMR) is a powerful technique to reveal and compare quantitative metabolic profiles of biological tissues. However, chemical and physical sample variations make the analysis of the data challenging, and typically require the application of a number of preprocessing steps prior to data interpretation. For example, noise reduction, normalization, baseline correction, peak picking, spectrum alignment and statistical analysis are indispensable components in any NMR analysis pipeline. We introduce a novel suite of informatics tools for the quantitative analysis of NMR metabolomic profile data. The core of the processing cascade is a novel peak alignment algorithm, called hierarchical Cluster-based Peak Alignment (CluPA). The algorithm aligns a target spectrum to the reference spectrum in a top-down fashion by building a hierarchical cluster tree from peak lists of reference and target spectra and then dividing the spectra into smaller segments based on the most distant clusters of the tree. To reduce the computational time to estimate the spectral misalignment, the method makes use of Fast Fourier Transformation (FFT) cross-correlation. Since the method returns a high-quality alignment, we can propose a simple methodology to study the variability of the NMR spectra. For each aligned NMR data point the ratio of the between-group and within-group sum of squares (BW-ratio) is calculated to quantify the difference in variability between and within predefined groups of NMR spectra. This differential analysis is related to the calculation of the F-statistic or a one-way ANOVA, but without distributional assumptions. Statistical inference based on the BW-ratio is achieved by bootstrapping the null distribution from the experimental data. The workflow performance was evaluated using a previously published dataset. Correlation maps, spectral and grey scale plots show clear improvements in comparison to other methods, and the down-to-earth quantitative analysis works well for the CluPA-aligned spectra. The whole workflow is embedded into a modular and statistically sound framework that is implemented as an R package called "speaq" ("spectrum alignment and quantitation"), which is freely available from http://code.google.com/p/speaq/.

  19. Atmospheric lidar co-alignment sensor: flight model electro-optical characterization campaign

    NASA Astrophysics Data System (ADS)

    Valverde Guijarro, Ángel Luis; Belenguer Dávila, Tomás.; Laguna Hernandez, Hugo; Ramos Zapata, Gonzalo

    2017-10-01

    Due to the difficulty in studying the upper layer of the troposphere by using ground-based instrumentation, the conception of a space-orbit atmospheric LIDAR (ATLID) becomes necessary. ATLID born in the ESA's EarthCare Programme framework as one of its payloads, being the first instrument of this kind that will be in the Space. ATLID will provide vertical profiles of aerosols and thin clouds, separating the relative contribution of aerosol and molecular scattering to know aerosol optical depth. It operates at a wavelength of 355 nm and has a high spectral resolution receiver and depolarization channel with a vertical resolution up to 100m from ground to an altitude of 20 km and, and up to 500m from 20km to 40km. ATLID measurements will be done from a sun-synchronous orbit at 393 km altitude, and an alignment (co-alignment) sensor (CAS) is revealed as crucial due to the way in which LIDAR analyses the troposphere. As in previous models, INTA has been in charge of part of the ATLID instrument co-alignment sensor (ATLID-CAS) electro-optical characterization campaign. CAS includes a set of optical elements to take part of the useful signal, to direct it onto the memory CCD matrix (MCCD) used for the co-alignment determination, and to focus the selected signal on the MCCD. Several tests have been carried out for a proper electro-optical characterization: CAS line of sight (LoS) determination and stability, point spread function (PSF), absolute response (AbsRes), pixel response non uniformity (PRNU), response linearity (ResLin) and spectral response. In the following lines, a resume of the flight model electrooptical characterization campaign is reported on. In fact, results concerning the protoflight model (CAS PFM) will be summarized. PFM requires flight-level characterization, so most of the previously mentioned tests must be carried out under simulated working conditions, i.e., the vacuum level (around 10-5 mbar) and temperature range (between 50°C and -30°C) that are expected during ATLID Space operation.

  20. Radiographic analysis of the correlation between ossification of the nuchal ligament and sagittal alignment and segmental stability of the cervical spine in patients with cervical spondylotic myelopathy.

    PubMed

    Ying, Jinwei; Teng, Honglin; Qian, Yunfan; Hu, Yingying; Wen, Tianyong; Ruan, Dike; Zhu, Minyu

    2018-01-01

    Background Ossification of the nuchal ligament (ONL) caused by chronic injury to the nuchal ligament (NL) is very common in instability-related cervical disorders. Purpose To determine possible correlations between ONL, sagittal alignment, and segmental stability of the cervical spine. Material and Methods Seventy-three patients with cervical spondylotic myelopathy (CSM) and ONL (ONL group) and 118 patients with CSM only (control group) were recruited. Radiographic data included the characteristics of ONL, sagittal alignment and segmental stability, and ossification of the posterior longitudinal ligament (OPLL). We performed comparisons in terms of radiographic parameters between the ONL and control groups. The correlations between ONL size, cervical sagittal alignment, and segmental stability were analyzed. Multivariate logistic regression was used to identify the independent risk factors of the development of ONL. Results C2-C7 sagittal vertical axis (SVA), T1 slope (T1S), T1S minus cervical lordosis (T1S-CL) on the lateral plain, angular displacement (AD), and horizontal displacement (HD) on the dynamic radiograph increased significantly in the ONL group compared with the control group. The size of ONL significantly correlated with C2-C7 SVA, T1S, AD, and HD. The incidence of ONL was higher in patients with OPLL and segmental instability. Cervical instability, sagittal malalignment, and OPLL were independent predictors of the development of ONL through multivariate analysis. Conclusion Patients with ONL are more likely to have abnormal sagittal alignment and instability of the cervical spine. Thus, increased awareness and appreciation of this often-overlooked radiographic finding is warranted during diagnosis and treatment of instability-related cervical pathologies and injuries.

  1. Current data do not support routine use of patient-specific instrumentation in total knee arthroplasty.

    PubMed

    Voleti, Pramod B; Hamula, Mathew J; Baldwin, Keith D; Lee, Gwo-Chin

    2014-09-01

    The purpose of this systematic review and meta-analysis is to compare patient-specific instrumentation (PSI) versus standard instrumentation for total knee arthroplasty (TKA) with regard to coronal and sagittal alignment, operative time, intraoperative blood loss, and cost. A systematic query in search of relevant studies was performed, and the data published in these studies were extracted and aggregated. In regard to coronal alignment, PSI demonstrated improved accuracy in femorotibial angle (FTA) (P=0.0003), while standard instrumentation demonstrated improved accuracy in hip-knee-ankle angle (HKA) (P=0.02). Importantly, there were no differences between treatment groups in the percentages of FTA or HKA outliers (>3 degrees from target alignment) (P=0.7). Sagittal alignment, operative time, intraoperative blood loss, and cost were also similar between groups (P>0.1 for all comparisons). Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Alignment of learning objectives and assessments in therapeutics courses to foster higher-order thinking.

    PubMed

    FitzPatrick, Beverly; Hawboldt, John; Doyle, Daniel; Genge, Terri

    2015-02-17

    To determine whether national educational outcomes, course objectives, and classroom assessments for 2 therapeutics courses were aligned for curricular content and cognitive processes, and if they included higher-order thinking. Document analysis and student focus groups were used. Outcomes, objectives, and assessment tasks were matched for specific therapeutics content and cognitive processes. Anderson and Krathwohl's Taxonomy was used to define higher-order thinking. Students discussed whether assessments tested objectives and described their thinking when responding to assessments. There were 7 outcomes, 31 objectives, and 412 assessment tasks. The alignment for content and cognitive processes was not satisfactory. Twelve students participated in the focus groups. Students thought more short-answer questions than multiple choice questions matched the objectives for content and required higher-order thinking. The alignment analysis provided data that could be used to reveal and strengthen the enacted curriculum and improve student learning.

  3. Atomic-scale inversion of spin polarization at an organic-antiferromagnetic interface

    NASA Astrophysics Data System (ADS)

    Caffrey, Nuala M.; Ferriani, Paolo; Marocchi, Simone; Heinze, Stefan

    2013-10-01

    Using first-principles calculations, we show that the magnetic properties of a two-dimensional antiferromagnetic transition-metal surface are modified on the atomic scale by the adsorption of small organic molecules. We consider benzene (C6H6), cyclooctatetraene (C8H8), and a small transition-metal-benzene complex (BzV) adsorbed on a single atomic layer of Mn deposited on the W(110) surface—a surface which exhibits a nearly antiferromagnetic alignment of the magnetic moments in adjacent Mn rows. Due to the spin dependent hybridization of the molecular pz orbitals with the d states of the Mn monolayer, there is a significant reduction of the magnetic moments in the Mn film. Furthermore, the spin polarization at this organic-antiferromagnetic interface is found to be modulated on the atomic scale, both enhanced and inverted, as a result of the molecular adsorption. We show that this effect can be resolved by spin-polarized scanning tunneling microscopy (SP-STM). Our simulated SP-STM images display a spatially dependent spin resolved vacuum charge density above an adsorbed molecule—i.e., different regions above the molecule sustain different signs of spin polarization. While states with s and p symmetry dominate the vacuum charge density in the vicinity of the Fermi energy for the clean magnetic surface, we demonstrate that after a molecule is adsorbed those d states, which are normally suppressed due to their symmetry, can play a crucial role in the vacuum due to their interaction with the molecular orbitals. We also model the effect of small deviations from perfect antiferromagnetic ordering, induced by the slight canting of magnetic moments due to the spin spiral ground state of Mn/W(110).

  4. Influence of ethanol on dentin roughness, surface free energy, and interaction between AH Plus and root dentin.

    PubMed

    Pantoja, Carlos Augusto de Morais Souto; Silva, Diogo Henrique da; Soares, Adriana de Jesus; Ferraz, Caio Cezar Randi; Gomes, Brenda Paula Figueiredo de Almeida; Zaia, Alexandre Augusto; Almeida, José Flávio Affonso de

    2018-01-01

    This study aimed to evaluate the influence of different ethanol concentrations on dentin roughness, surface free energy, and contact angle between AH Plus and the root canal dentin. One hundred human maxillary anterior teeth were split longitudinally and 200 dentin specimens were polished to make the surface flatter and smoother. An acrylic bar was positioned between two dentin specimens and impression material was added to create a block, simulating an instrumented root canal space. Specimens were removed from the mold and cleaned in an ultrasonic bath for 10 min. Thereafter, dentin specimens were divided into four groups (n = 50) according to the drying methods used: a) wet: vacuum only, b) paper points: vacuum + absorbent paper points, c) 70% alcohol: 70% alcohol (1 min) + vacuum + absorbent paper points, and d) 100% alcohol: 100% alcohol (1 min) + vacuum + absorbent paper points. A rugosimeter and a goniometer were used to verify the roughness (Ra) and to measure the surface free energy and the contact angle between the AH Plus sealer and the root canal dentin. ANOVA and Tukey tests (α = 0.05) were used for statistical analysis. The 70% and 100% ethanol groups showed significantly decreased roughness as well as increased surface free energy in the root canal dentin when compared to the wet and paper point groups. In addition, ethanol significantly reduced the contact angle between the AH Plus sealer and the root canal dentin. Ethanol solutions (70% and 100%) provide better wettability of AH Plus sealer on dentin surfaces.

  5. TMRG studies on spin alignment in molecule-based ferrimagnetics [rapid communication

    NASA Astrophysics Data System (ADS)

    Liu, Q. M.; Yao, K. L.; Liu, Z. L.

    2005-05-01

    A physical picture of spin alignment in organic molecule-based ferrimagnets is presented from studying the thermal effective magnetic moment of the sublattice by use of the transfer matrix renormalization group. We conclude that the classical antiparallel spin alignment is not the most stable state. The three-spin system tends to parallel alignment when the exchange interaction between the biradical and the monoradical molecules is much weaker than that within the biradical, which can result in the decrease of the effective magnetic moment upon lowering the temperature. More importantly, we give the theoretical evidence that even the antiparallel spin alignment in the biradical monoradical alternating chain does not necessarily lead to ferrimagnetic spin ordering due to the formation of the spin singlet pairs, which suppresses the ferrimagnetic spin alignment.

  6. Effects of surface condition on the work function and valence-band position of ZnSnN2

    NASA Astrophysics Data System (ADS)

    Shing, Amanda M.; Tolstova, Yulia; Lewis, Nathan S.; Atwater, Harry A.

    2017-12-01

    ZnSnN2 is an emerging wide band gap earth-abundant semiconductor with potential applications in photonic devices such as solar cells, LEDs, and optical sensors. We report the characterization by ultraviolet photoelectron spectroscopy and X-ray photoelectron spectroscopy of reactively radio-frequency sputtered II-IV-nitride ZnSnN2 thin films. For samples transferred in high vacuum, the ZnSnN2 surface work function was 4.0 ± 0.1 eV below the vacuum level, with a valence-band onset of 1.2 ± 0.1 eV below the Fermi level. The resulting band diagram indicates that the degenerate bulk Fermi level position in ZnSnN2 shifts to mid-gap at the surface due to band bending that results from equilibration with delocalized surface states within the gap. Brief (< 10 s) exposures to air, a nitrogen-plasma treatment, or argon-ion sputtering caused significant chemical changes at the surface, both in surface composition and interfacial energetics. The relative band positioning of the n-type semiconductor against standard redox potentials indicated that ZnSnN2 has an appropriate energy band alignment for use as a photoanode to effect the oxygen-evolution reaction.

  7. Secondary Structure Prediction of Protein Constructs Using Random Incremental Truncation and Vacuum-Ultraviolet CD Spectroscopy

    PubMed Central

    Pukáncsik, Mária; Orbán, Ágnes; Nagy, Kinga; Matsuo, Koichi; Gekko, Kunihiko; Maurin, Damien; Hart, Darren; Kézsmárki, István; Vertessy, Beata G.

    2016-01-01

    A novel uracil-DNA degrading protein factor (termed UDE) was identified in Drosophila melanogaster with no significant structural and functional homology to other uracil-DNA binding or processing factors. Determination of the 3D structure of UDE is excepted to provide key information on the description of the molecular mechanism of action of UDE catalysis, as well as in general uracil-recognition and nuclease action. Towards this long-term aim, the random library ESPRIT technology was applied to the novel protein UDE to overcome problems in identifying soluble expressing constructs given the absence of precise information on domain content and arrangement. Nine constructs of UDE were chosen to decipher structural and functional relationships. Vacuum ultraviolet circular dichroism (VUVCD) spectroscopy was performed to define the secondary structure content and location within UDE and its truncated variants. The quantitative analysis demonstrated exclusive α-helical content for the full-length protein, which is preserved in the truncated constructs. Arrangement of α-helical bundles within the truncated protein segments suggested new domain boundaries which differ from the conserved motifs determined by sequence-based alignment of UDE homologues. Here we demonstrate that the combination of ESPRIT and VUVCD spectroscopy provides a new structural description of UDE and confirms that the truncated constructs are useful for further detailed functional studies. PMID:27273007

  8. Progress in Laser Risk Reduction for 1 micron lasers at GSFC

    NASA Technical Reports Server (NTRS)

    Heaps, William S.

    2007-01-01

    In recent years, lasers have proven themselves to be invaluable to a variety of remote sensing applications. LIDAR techniques have been used to measure atmospheric aerosols and a variety of trace species, profile winds, and develop high resolution topographical maps. Often it would be of great advantage to make these measurements from an orbiting satellite. Unfortunately, the space environment is a challenging one for the high power lasers that would enable many LIDAR missions. Optical mounts must maintain precision alignment during and after launch. Outgassing materials in the vacuum of space lead to contamination of laser optics. Electronic components and optical materials must survive the space environment, including a vacuum atmosphere, thermal cycling, and radiation exposure. Laser designs must be lightweight, compact, and energy efficient. Many LIDAR applications require frequency conversion systems that have never been designed or tested for use in space. For the last six years the National Aeronautical and Space Administration (NASA) has undertaken a program specifically directed at addressing the durability and long term reliability issues that face space-borne lasers. The effort is shared between NASA Goddard Space Flight Center in Greenbelt, Maryland, and NASA Langley Research Center in Hampton, Virginia. This paper is an overview of the issues facing space-borne lasers and the efforts that Goddard has been pursuing to address them.

  9. Ion projection lithography: November 2000 status and sub-70-nm prospects

    NASA Astrophysics Data System (ADS)

    Kaesmaier, Rainer; Wolter, Andreas; Loeschner, Hans; Schunck, Stefan

    2000-10-01

    Among all next generation lithography (NGL) options Ion Projection Lithography (IPL) offers the smallest (particle) wavelength of 5x10- 5nm (l00keV Helium ions). Thus, 4x reduction ion-optics has diffraction limits <3nm even when using a numerical aperture as low as NAequals10-5. As part of the European MEDEA IPL project headed by Infineon Technologies wide field ion-optics have been designed by IMS- Vienna with predicted resolution of 50nm within a 12.5mm exposure field. The ion-optics part of the PDT tool (PDT-IOS) has been realized and assembled. In parallel to the PDT-IOS effort, at Leica Jena a test bench for a vertical vacuum 300mm-wafer stage has been realized. Operation of magnetic bearing supported stage movement has already been demonstrated. As ASML vacuum compatible optical wafer alignment system, with 3nm(3(sigma) ) precision demonstrated in air, has been integrated to this wafer test bench system recently. Parallel to the IPL tool development, Infineon Technologies Mask House and the Institute for Microelectronics Stuttgart are intensively working on the development of IPL stencil masks with success in producing 150mm and 200mm stencil masks as reported elsewhere. This paper is focused on information about the status of the PDT-IOS tool.

  10. Combined CT-based and image-free navigation systems in TKA reduces postoperative outliers of rotational alignment of the tibial component.

    PubMed

    Mitsuhashi, Shota; Akamatsu, Yasushi; Kobayashi, Hideo; Kusayama, Yoshihiro; Kumagai, Ken; Saito, Tomoyuki

    2018-02-01

    Rotational malpositioning of the tibial component can lead to poor functional outcome in TKA. Although various surgical techniques have been proposed, precise rotational placement of the tibial component was difficult to accomplish even with the use of a navigation system. The purpose of this study is to assess whether combined CT-based and image-free navigation systems replicate accurately the rotational alignment of tibial component that was preoperatively planned on CT, compared with the conventional method. We compared the number of outliers for rotational alignment of the tibial component using combined CT-based and image-free navigation systems (navigated group) with those of conventional method (conventional group). Seventy-two TKAs were performed between May 2012 and December 2014. In the navigated group, the anteroposterior axis was prepared using CT-based navigation system and the tibial component was positioned under control of the navigation. In the conventional group, the tibial component was placed with reference to the Akagi line that was determined visually. Fisher's exact probability test was performed to evaluate the results. There was a significant difference between the two groups with regard to the number of outliers: 3 outliers in the navigated group compared with 12 outliers in the conventional group (P < 0.01). We concluded that combined CT-based and image-free navigation systems decreased the number of rotational outliers of tibial component, and was helpful for the replication of the accurate rotational alignment of the tibial component that was preoperatively planned.

  11. Cervical spine alignment in the pediatric population: a radiographic normative study of 150 asymptomatic patients.

    PubMed

    Abelin-Genevois, K; Idjerouidene, A; Roussouly, P; Vital, J M; Garin, C

    2014-07-01

    To describe the normal cervical sagittal alignment of the pediatric spine in a normal population and to identify the changes during growth period. We randomly selected in PACS database 150 full-spine standing views. Exclusion criteria were: age >18 years, spinal deformity and any disease affecting the spine (medical charts reviewing). For cervical alignment we measured: OC-angle according to Mc Gregor, C1C7 angle, upper cervical angle, inferior cervical angle and C7 tilt. Spino pelvic parameters were analyzed: T1 tilt, thoracic kyphosis, lumbar lordosis, pelvic incidence, sacral slope and pelvic tilt. We compared two age subgroups (juvenile and adolescent). Differences between age groups and gender were tested using Student's t test. Correlations between sagittal spinal parameters were evaluated using Pearson's test. Cervical spine shape was correlated to cranio cervical orientation to maintain horizontal gaze (r = 0.60) and to thoracic kyphosis (r = -0.46). Cervical spine alignment was significantly different between the two age groups except for the global C1C7 cervical lordosis, which remained stable. A significant gender difference was found for all the cervical sagittal angles (p < 0.01) whereas no differences were demonstrated for the spino pelvic parameters, except the lumbar lordosis (p = 0.047). This study is the first to report the cervical spinal alignment in a normal pediatric Caucasian population. Even though cervical lordosis is the common shape, our results showed variability in cervical sagittal alignment. Cervical spine is a junctional area that adjusts its alignment to the head position and to the underlying spinal alignment.

  12. Highly aligned vertical GaN nanowires using submonolayer metal catalysts

    DOEpatents

    Wang, George T [Albuquerque, NM; Li, Qiming [Albuquerque, NM; Creighton, J Randall [Albuquerque, NM

    2010-06-29

    A method for forming vertically oriented, crystallographically aligned nanowires (nanocolumns) using monolayer or submonolayer quantities of metal atoms to form uniformly sized metal islands that serve as catalysts for MOCVD growth of Group III nitride nanowires.

  13. Results from the First Beam-Induced Reconstructed Tracks in the LHCb Vertex Locator

    NASA Astrophysics Data System (ADS)

    Rodrigues, E.

    2010-04-01

    LHCb is a dedicated experiment at the LHC to study CP violation and rare b decays. The vertex locator (VELO) is a silicon strip detector designed to measure precisely the production and decay vertices of B-mesons. The detector is positioned at 8 mm of the LHC beams and will operate in an extremely harsh radiation environment. The VELO consists of two retractable detector halves with 21 silicon micro-strip tracking modules each. A module is composed of two n+-on-n 300 μm thick half disc sensors with R and Φ micro-strip geometry. The detectors are operated in vacuum and a bi-phase CO2 cooling system is used. The full system has been operated since June 2008 and its commissioning experience will be reported. During the LHC synchronization tests in August and September 2008, and June 2009 the LHCb detectors measured secondary particles produced by the interaction of the LHC primary beam on a beam dump. About 50,000 tracks were reconstructed in the VELO and they were used to derive the relative timing alignment between the sensors and for the first evaluation of the spatial alignment. Using this track sample the VELO has been aligned to an accuracy of 5 μm. A single hit resolution of 10 μm was obtained at the smallest pitch for tracks of perpendicular incidence. The design and the main components of the detector system are introduced. The commissioning of the detector is reported and the talk will focus on the results obtained using the first beam-induced reconstructed tracks.

  14. Precision mechanisms for optics in a vacuum cryogenic environment

    NASA Astrophysics Data System (ADS)

    Navarro, R.; Elswijk, E.; Tromp, N.; Kragt, J.; Kroes, G.; Hanenburg, H.; de Haan, M.; Schuil, M.; Teuwen, M.; Janssen, H.; Venema, L.

    2017-11-01

    To achieve superb stability in cryogenic optical systems, NOVA-ASTRON generally designs optical instruments on the basis of a 'no adjustments' philosophy. This means that in principle no corrections are possible after assembly. The alignment precision and consequently the performance of the instrument is guaranteed from the design, the tolerance analysis and the detailed knowledge of the material behavior and manufacturing process. This resulted in a higher degree of integrated optomechanical-cryogenic design with fewer parts, but with a higher part complexity. The 'no adjustments' strategy is successful because in the end the risk on instrument performance and project delays is much reduced. Astronomical instrument specifications have become more challenging over the years. Recent designs of the European Southern Observatory Very Large Telescope Interferometer (ESO VLTI) 4 Telescope combiner MATISSE include hundreds of optical components in a cryogenic environment. Despite the large number of optical components the alignment accuracy and stability requirements are in the order of nanometers. The 'no adjustments' philosophy would be too costly in this case, because all components would need to meet extremely tight manufacturing specifications. These specifications can be relaxed dramatically if cryogenic mechanisms are used for alignment. Several mechanisms have been developed: a tip-tilt mirror mechanism, an optical path distance mechanism, a slider mechanism, a bistable cryogenic shutter and a mirror mounting clip. Key aspects of these mechanisms are that the optical element and mechanism are combined in a compact single component, driven by e.g. self braking piezo actuators in order to hold position without power. The design, realization and test results of several mechanisms are presented in this paper.

  15. Orbital alignment at the internal interface of arylthiol functionalized CdSe molecular hybrids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhi; Schlaf, Rudy, E-mail: schlaf@usf.edu; Mazzio, Katherine A.

    Organic-inorganic nanoparticle molecular hybrid materials are interesting candidates for improving exciton separation in organic solar cells. The orbital alignment at the internal interface of cadmium selenide (ArS-CdSe) hybrid materials functionalized with covalently attached arylthiolate moieties was investigated through X-ray photoemission spectroscopy (XPS) and ultraviolet photoemission spectroscopy (UPS). A physisorbed interface between arylthiol (ArSH) ligands and CdSe nanoparticles was also investigated for comparison. This interface was created via a multi-step thin film deposition procedure in-vacuo, where the surface was characterized after each experimental step. This enabled the direct comparison of ArSH/CdSe interfaces produced via physisorption and ArS-CdSe covalently attached hybrid materials,more » which rely on a chemical reaction for their synthesis. All material depositions were performed using an electrospray deposition, which enabled the direct injection of solution-originating molecular species into the vacuum system. This method allows XPS and UPS measurements to be performed immediately after deposition without exposure to the atmosphere. Transmission electron microscopy was used to determine the morphology and particle size of the deposited materials. Ultraviolet-visible spectroscopy was used to estimate the optical band gap of the CdSe nanoparticles and the HOMO-LUMO gap of the ArSH ligands. These experiments showed that hybridization via covalent bonds results in an orbital realignment at the ArSH/CdSe interface in comparison to the physisorbed interface. The orbital alignment within the hybrid caused a favorable electron injection barrier, which likely facilitates exciton-dissociation while preventing charge-recombination.« less

  16. (In)dependence of 𝜃 in the Higgs regime without axions

    NASA Astrophysics Data System (ADS)

    Shifman, Mikhail; Vainshtein, Arkady

    2017-05-01

    We revisit the issue of the vacuum angle 𝜃 dependence in weakly coupled (Higgsed) Yang-Mills theories. Two most popular mechanisms for eliminating physical 𝜃 dependence are massless quarks and axions. Anselm and Johansen noted that the vacuum angle 𝜃EW, associated with the electroweak SU(2) in the Glashow-Weinberg-Salam model (Standard Model, SM), is unobservable although all fermion fields obtain masses through Higgsing and there is no axion. We generalize this idea to a broad class of Higgsed Yang-Mills theories. In the second part, we consider the consequences of Grand Unification. We start from a unifying group, e.g. SU(5), at a high ultraviolet scale and evolve the theory down within the Wilson procedure. If on the way to infrared the unifying group is broken down into a few factors, all factor groups inherit one and the same 𝜃 angle — that of the unifying group. We show that embedding the SM in SU(5) drastically changes the Anselm-Johansen conclusion: the electroweak vacuum angle 𝜃EW, equal to 𝜃QCD becomes in principle observable in ΔB = ΔL = ±1 processes. We also note in passing that if the axion mechanism is set up above the unification scale, we have one and the same axion in the electroweak theory and QCD, and their impacts are interdependent.

  17. Physician clinical alignment and integration: a community-academic hospital approach.

    PubMed

    Salas-Lopez, Debbie; Weiss, Sandra Jarva; Nester, Brian; Whalen, Thomas

    2014-01-01

    An overwhelming need for change in the U.S. healthcare delivery system, coupled with the need to improve clinical and financial outcomes, has prompted hospitals to direct renewed efforts toward achieving high quality and cost-effectiveness. Additionally, with the dawn of accountable care organizations and increasing focus on patient expectations, hospitals have begun to seek physician partners through clinical alignment. Contrary to the unsuccessful alignment strategies of the 1990s, today's efforts are more mutually beneficial, driven by the need to achieve better care coordination, increased access to infrastructure, improved quality, and lower costs. In this article, we describe a large, academic, tertiary care hospital's approach to developing and implementing alignment and integration models with its collaboration-ready physicians and physician groups. We developed four models--short of physicians' employment with the organization--tailored to meet the needs of both the physician group and the hospital: (1) medical directorship (group physicians are appointed to serve as medical directors of a clinical area), (2) professional services agreement (specific clinical services, such as overnight admissions help, are contracted), (3) co-management services agreement (one specialty group co-manages all services within the specialty service lines), and (4) lease arrangement (closest in scope to employment, in which the hospital pays all expenses and receives all revenue). Successful hospital-physician alignment requires careful planning and the early engagement of legal counsel to ensure compliance with federal statutes. Establishing an integrated system with mutually identified goals better positions hospitals to deliver cost-effective and high-quality care under the new paradigm of healthcare reform.

  18. Phylogenetic relationships within the cyst-forming nematodes (Nematoda, Heteroderidae) based on analysis of sequences from the ITS regions of ribosomal DNA.

    PubMed

    Subbotin, S A; Vierstraete, A; De Ley, P; Rowe, J; Waeyenberge, L; Moens, M; Vanfleteren, J R

    2001-10-01

    The ITS1, ITS2, and 5.8S gene sequences of nuclear ribosomal DNA from 40 taxa of the family Heteroderidae (including the genera Afenestrata, Cactodera, Heterodera, Globodera, Punctodera, Meloidodera, Cryphodera, and Thecavermiculatus) were sequenced and analyzed. The ITS regions displayed high levels of sequence divergence within Heteroderinae and compared to outgroup taxa. Unlike recent findings in root knot nematodes, ITS sequence polymorphism does not appear to complicate phylogenetic analysis of cyst nematodes. Phylogenetic analyses with maximum-parsimony, minimum-evolution, and maximum-likelihood methods were performed with a range of computer alignments, including elision and culled alignments. All multiple alignments and phylogenetic methods yielded similar basic structure for phylogenetic relationships of Heteroderidae. The cyst-forming nematodes are represented by six main clades corresponding to morphological characters and host specialization, with certain clades assuming different positions depending on alignment procedure and/or method of phylogenetic inference. Hypotheses of monophyly of Punctoderinae and Heteroderinae are, respectively, strongly and moderately supported by the ITS data across most alignments. Close relationships were revealed between the Avenae and the Sacchari groups and between the Humuli group and the species H. salixophila within Heteroderinae. The Goettingiana group occupies a basal position within this subfamily. The validity of the genera Afenestrata and Bidera was tested and is discussed based on molecular data. We conclude that ITS sequence data are appropriate for studies of relationships within the different species groups and less so for recovery of more ancient speciations within Heteroderidae. Copyright 2001 Academic Press.

  19. Multilayer capacitor suitable for substrate integration and multimegahertz filtering

    DOEpatents

    Ngo, Khai D. T.

    1990-01-01

    A multilayer capacitor comprises stacked, spaced-apart electrodes of sheet form, dielectric layers between the electrodes, and first and second groups of spaced-apart conductive vias extending transversely of the sheet-form electrodes and through aligned holes in the dielectric layers. Alternate electrodes are instantaneously positive, and the remaining electrodes are instantaneously negative. Each via of the first group is electrically connected to the positive electrodes and passes insulatingly through the negative electrodes. Similarly, each via of the second group is electrically connected to the negative electrodes and passes insulatingly through the positive electrodes. Each via has, in the plane of the electrodes, a cross-sectional form in the shape of an elongated rib of greater length than width. The elongated ribs of the first group are disposed in a first plurality of rows with their lengths in spaced-apart, aligned relationship, and the ribs of the second group are disposed in a second plurality of rows with their lengths in spaced-apart, aligned relationship. The first plurality of rows is disposed substantially orthogonally with respect to the second plurality of rows.

  20. Generation of multicolor vacuum ultraviolet pulses through four-wave sum-frequency mixing in argon

    NASA Astrophysics Data System (ADS)

    Shi, Liping; Li, Wenxue; Zhou, Hui; Wang, Di; Ding, Liang'en; Zeng, Heping

    2013-11-01

    We demonstrate efficient generation of multicolor vacuum ultraviolet pulses with excellent mode quality through χ(3)-based four-wave sum-frequency mixing and third-order harmonic generation of 400- and 267-nm femtosecond laser pulses in argon gas. The χ(3)-based nonlinear optical processes were optimized with appropriate control of gas pressure and group velocity delay between the driving pulses. Furthermore, the pulse breakup effects were observed for tightly focused ultraviolet pulses.

  1. Reverse alignment "mirror image" visualization as a laparoscopic training tool improves task performance.

    PubMed

    Dunnican, Ward J; Singh, T Paul; Ata, Ashar; Bendana, Emma E; Conlee, Thomas D; Dolce, Charles J; Ramakrishnan, Rakesh

    2010-06-01

    Reverse alignment (mirror image) visualization is a disconcerting situation occasionally faced during laparoscopic operations. This occurs when the camera faces back at the surgeon in the opposite direction from which the surgeon's body and instruments are facing. Most surgeons will attempt to optimize trocar and camera placement to avoid this situation. The authors' objective was to determine whether the intentional use of reverse alignment visualization during laparoscopic training would improve performance. A standard box trainer was configured for reverse alignment, and 34 medical students and junior surgical residents were randomized to train with either forward alignment (DIRECT) or reverse alignment (MIRROR) visualization. Enrollees were tested on both modalities before and after a 4-week structured training program specific to their modality. Student's t test was used to determine differences in task performance between the 2 groups. Twenty-one participants completed the study (10 DIRECT, 11 MIRROR). There were no significant differences in performance time between DIRECT or MIRROR participants during forward or reverse alignment initial testing. At final testing, DIRECT participants had improved times only in forward alignment performance; they demonstrated no significant improvement in reverse alignment performance. MIRROR participants had significant time improvement in both forward and reverse alignment performance at final testing. Reverse alignment imaging for laparoscopic training improves task performance for both reverse alignment and forward alignment tasks. This may be translated into improved performance in the operating room when faced with reverse alignment situations. Minimal lab training can account for drastic adaptation to this environment.

  2. Effects of vacuum suctioning and strategic drape tenting on oxygen concentration in a simulated surgical field.

    PubMed

    Kung, Theodore A; Kong, Sarah W; Aliu, Oluseyi; Azizi, Jahan; Kai, Salim; Cederna, Paul S

    2016-02-01

    To investigate the isolated and combined effects of vacuum suctioning and strategic drape tenting on oxygen concentration in an experimental setting. Experimental. Clinical simulation center of a university-affiliated hospital. Mannequin simulation of a patient undergoing facial surgery under sedation anesthesia. Supplemental oxygen was delivered via nasal cannula. Vacuum suctioning and strategic drape tenting. The experimental trials entailed measuring oxygen concentration around the nasal cannula continuously either in the presence or absence of a standard operating room vacuum suction system and strategic tenting of surgical drapes. The primary outcome was the time required for oxygen concentration to reach 21%. In the control group (without suction or strategic tenting), a mean time of 180 seconds elapsed until the measured oxygen concentration reached 21% after cessation of oxygen delivery. Use of a vacuum suction device alone (110 seconds; P < .01) or in combination with strategic tenting (110 seconds; P < .01) significantly reduced this time. No significant benefit was seen when tenting was used alone (160 seconds; P < .30). Use of a vacuum suction device during surgery will lower local oxygen concentration, and this in turn may decrease the risk of operating room fires. Although strategic tenting of surgical drapes has a theoretical benefit to decreasing the pooling of oxygen around the surgical site, further investigation is necessary before its routine use is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Census taking in the hat: FRW/CFT duality

    NASA Astrophysics Data System (ADS)

    Sekino, Yasuhiro; Susskind, Leonard

    2009-10-01

    In this paper a holographic description of eternal inflation is developed. We focus on the description of an open Friedmann-Robertson-Walker (FRW) universe that results from a tunneling event in which a false vacuum with positive vacuum energy decays to a supersymmetric vacuum with vanishing cosmological constant. The observations of a “census taker” in the final vacuum can be organized into a holographic dual conformal field theory that lives on the asymptotic boundary of space. We refer to this bulk-boundary correspondence as FRW/CFT duality. The dual conformal field theory (CFT) is a Euclidean two-dimensional theory that includes a Liouville 2D gravity sector describing geometric fluctuations of the boundary. The renormalization-group flow of the theory is richer than in the AdS/CFT correspondence, and generates two space-time dimensions—one spacelike and one timelike. We discuss a number of phenomena such as bubble collisions, and the Garriga, Guth Vilenkin “persistence of memory,” from the dual viewpoint.

  4. First results from the new PVLAS apparatus: A new limit on vacuum magnetic birefringence

    NASA Astrophysics Data System (ADS)

    Della Valle, F.; Milotti, E.; Ejlli, A.; Messineo, G.; Piemontese, L.; Zavattini, G.; Gastaldi, U.; Pengo, R.; Ruoso, G.

    2014-11-01

    Several groups are carrying out experiments to observe and measure vacuum magnetic birefringence, predicted by quantum electrodynamics (QED). We have started running the new PVLAS apparatus installed in Ferrara, Italy, and have measured a noise floor value for the unitary field magnetic birefringence of vacuum Δ nu(vac )=(4 ±20 )×1 0-23 T-2 (the error represents a 1 σ deviation). This measurement is compatible with zero and hence represents a new limit on vacuum magnetic birefringence deriving from nonlinear electrodynamics. This result reduces to a factor of 50 the gap to be overcome to measure for the first time the value of Δ nu(vac ,QED ) predicted by QED: Δ nu(vac ,QED )=4 ×10-24 T-2 . These birefringence measurements also yield improved model-independent bounds on the coupling constant of axion-like particles to two photons, for masses greater than 1 meV, along with a factor-2 improvement of the fractional charge limit on millicharged particles (fermions and scalars), including neutrinos.

  5. Paving asphalt products exhibit a lack of carcinogenic and mutagenic activity.

    PubMed

    Goyak, Katy O; McKee, Richard H; Minsavage, Gary D; McGowan, Claude; Daughtrey, Wayne C; Freeman, James J

    2011-10-01

    A paving asphalt and a vacuum residuum (derived from crude oil by atmospheric and subsequent vacuum distillation and used as a blend stock for asphalt) were tested in skin carcinogenesis assays in mice and in optimized Ames assays for mutagenic activity. In the skin cancer tests, each substance was applied twice weekly for 104 weeks to the clipped backs of groups of 50 male C3H mice. Neither the paving asphalt nor the vacuum residuum (30% weight/volume and 75% weight/weight in US Pharmacopeia mineral oil, respectively) produced any tumors. The positive control benzo[a]pyrene (0.05% w/v in toluene) induced tumors in 46 of 50 mice, demonstrating the effectiveness of the test method. Salmonella typhimurium tester strain TA98 was used in the optimized Ames assay to evaluate mutagenic potential. Dimethylsulfoxide (DMSO) extractions of the substances were not mutagenic when tested up to toxic limits. Thus, under the conditions of these studies, neither the paving asphalt nor the vacuum residuum was carcinogenic or mutagenic.

  6. Image-based quantification of fiber alignment within electrospun tissue engineering scaffolds is related to mechanical anisotropy.

    PubMed

    Fee, Timothy; Downs, Crawford; Eberhardt, Alan; Zhou, Yong; Berry, Joel

    2016-07-01

    It is well documented that electrospun tissue engineering scaffolds can be fabricated with variable degrees of fiber alignment to produce scaffolds with anisotropic mechanical properties. Several attempts have been made to quantify the degree of fiber alignment within an electrospun scaffold using image-based methods. However, these methods are limited by the inability to produce a quantitative measure of alignment that can be used to make comparisons across publications. Therefore, we have developed a new approach to quantifying the alignment present within a scaffold from scanning electron microscopic (SEM) images. The alignment is determined by using the Sobel approximation of the image gradient to determine the distribution of gradient angles with an image. This data was fit to a Von Mises distribution to find the dispersion parameter κ, which was used as a quantitative measure of fiber alignment. We fabricated four groups of electrospun polycaprolactone (PCL) + Gelatin scaffolds with alignments ranging from κ = 1.9 (aligned) to κ = 0.25 (random) and tested our alignment quantification method on these scaffolds. It was found that our alignment quantification method could distinguish between scaffolds of different alignments more accurately than two other published methods. Additionally, the alignment parameter κ was found to be a good predictor the mechanical anisotropy of our electrospun scaffolds. The ability to quantify fiber alignment within and make direct comparisons of scaffold fiber alignment across publications can reduce ambiguity between published results where cells are cultured on "highly aligned" fibrous scaffolds. This could have important implications for characterizing mechanics and cellular behavior on aligned tissue engineering scaffolds. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1680-1686, 2016. © 2016 Wiley Periodicals, Inc.

  7. In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment.

    PubMed

    Cordasco, Giancarlo; Lo Giudice, Antonino; Militi, Angela; Nucera, Riccardo; Triolo, Giuseppe; Matarese, Giovanni

    2012-08-01

    To investigate the resistance to sliding (RS) in self-ligating and conventional ligation bracket systems at 5 different second-order bracket angulations by using low-stiffness alignment wires in a 3-bracket experimental model and to verify the performance of the main RS components in both systems when these wires are used. Interactive self-ligating brackets with closed and open slides were used for the self-ligating (SL) and conventional ligation (CL) groups, respectively; elastomeric ligatures (1 mm inner diameter) were used in the latter system. The alignment wire used was 0.014 inch heat-activated NiTi (austenitic finish temperature set at 36℃ by the manufacturer). A custom-made testing machine was used to measure frictional resistance. Tests were repeated 5 times at every angulation simulated. All data were analyzed statistically. The RS increased significantly with increasing angulation in both SL and CL groups (p < 0.0001). However, the RS values were significantly higher at every angulation (p < 0.0001) in the CL group. Despite the relevance of the binding phenomenon, ligation forces predominantly affect the RS when low-stiffness alignment wires are used.

  8. In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment

    PubMed Central

    Cordasco, Giancarlo; Lo Giudice, Antonino; Militi, Angela; Nucera, Riccardo; Triolo, Giuseppe

    2012-01-01

    Objective To investigate the resistance to sliding (RS) in self-ligating and conventional ligation bracket systems at 5 different second-order bracket angulations by using low-stiffness alignment wires in a 3-bracket experimental model and to verify the performance of the main RS components in both systems when these wires are used. Methods Interactive self-ligating brackets with closed and open slides were used for the self-ligating (SL) and conventional ligation (CL) groups, respectively; elastomeric ligatures (1 mm inner diameter) were used in the latter system. The alignment wire used was 0.014 inch heat-activated NiTi (austenitic finish temperature set at 36℃ by the manufacturer). A custom-made testing machine was used to measure frictional resistance. Tests were repeated 5 times at every angulation simulated. All data were analyzed statistically. Results The RS increased significantly with increasing angulation in both SL and CL groups (p < 0.0001). However, the RS values were significantly higher at every angulation (p < 0.0001) in the CL group. Conclusions Despite the relevance of the binding phenomenon, ligation forces predominantly affect the RS when low-stiffness alignment wires are used. PMID:23112953

  9. ATM test and integration. [Skylab Apollo Telescope Mount

    NASA Technical Reports Server (NTRS)

    Moore, J. W.; Mitchell, J. R.

    1974-01-01

    The test and checkout philosophy of the test program for the Skylab ATM module and the overall test flow including in-process, post-manufacturing, vibration, thermal vacuum, and prelaunch checkout activities are described. Capabilities and limitations of the test complex and its use of automation are discussed. Experiences with the organizational principle of using a dedicated test team for all checkout activities are reported. Material on the development of the ATM subsystems, the experimental program and the requirements of the scientific community, and the integration and verification of the complex systems/subsystems of the ATM are presented. The performance of the ATM test program in such areas as alignment, systems and subsystems, contamination control, and experiment operation is evaluated. The conclusions and recommendations resulting from the ATM test program are enumerated.

  10. THREE-DIMENSIONAL NON-VACUUM PULSAR OUTER-GAP MODEL: LOCALIZED ACCELERATION ELECTRIC FIELD IN THE HIGHER ALTITUDES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirotani, Kouichi

    2015-01-10

    We investigate the particle accelerator that arises in a rotating neutron-star magnetosphere. Simultaneously solving the Poisson equation for the electro-static potential, the Boltzmann equations for relativistic electrons and positrons, and the radiative transfer equation, we demonstrate that the electric field is substantially screened along the magnetic field lines by pairs that are created and separated within the accelerator. As a result, the magnetic-field-aligned electric field is localized in higher altitudes near the light cylinder and efficiently accelerates the positrons created in the lower altitudes outward but does not accelerate the electrons inward. The resulting photon flux becomes predominantly outward, leadingmore » to typical double-peak light curves, which are commonly observed from many high-energy pulsars.« less

  11. Development of a new in-air micro-PIXE set-up with in-vacuum charge measurements in Atomki

    NASA Astrophysics Data System (ADS)

    Török, Zs.; Huszánk, R.; Csedreki, L.; Dani, J.; Szoboszlai, Z.; Kertész, Zs.

    2015-11-01

    A new external microbeam set-up has recently been installed as the extension of the existing microprobe system at the Laboratory of Ion Beam Applications of Atomki, Debrecen, Hungary. The external beam set-up, based on the system of Oxford Microbeams (OM), is equipped with two X-ray detectors for PIXE analysis, a digital microscope, two alignment lasers and a precision XYZ stage for easy and reproducible positioning of the sample. Exit windows with different thicknesses and of different materials can be used according to the actual demands, currently silicon-nitride (Si3N4) film with 200 nm thickness is employed in our laboratory. The first application was demonstrated in the field of archaeometry, on Bronze Age hoards from Hungary.

  12. The Størmer problem for an aligned rotator

    NASA Astrophysics Data System (ADS)

    Epp, V.; Pervukhina, O. N.

    2018-03-01

    The effective potential energy of the particles in the field of rotating uniformly magnetized celestial body is investigated. The axis of rotation coincides with the axis of the magnetic field. Electromagnetic field of the body is composed of a dipole magnetic and quadrupole electric fields. The geometry of the trapping regions is studied as a function of the magnetic field magnitude and the rotation speed of the body. Examples of the potential energy topology for different values of these parameters are given. The main difference from the classical Størmer problem is that the single toroidal trapping region predicted by Størmer is divided into equatorial and off-equatorial trapping regions. Applicability of the idealized model of a rotating uniformly magnetized sphere with a vacuum magnetosphere to real celestial bodies is discussed.

  13. A Life Study of Ausforged, Standard Forged and Standard Machined AISI M-50 Spur Gears

    NASA Technical Reports Server (NTRS)

    Townsend, D. P.; Bamberger, E. N.; Zaretsky, E. V.

    1975-01-01

    Tests were conducted at 350 K (170 F) with three groups of 8.9 cm (3.5 in.) pitch diameter spur gears made of vacuum induction melted (VIM) consumable-electrode vacuum-arc melted (VAR), AISI M-50 steel and one group of vacuum-arc remelted (VAR) AISI 9310 steel. The pitting fatigue life of the standard forged and ausforged gears was approximately five times that of the VAR AISI 9310 gears and ten times that of the bending fatigue life of the standard machined VIM-VAR AISI M-50 gears run under identical conditions. There was a slight decrease in the 10-percent life of the ausforged gears from that for the standard forged gears, but the difference is not statistically significant. The standard machined gears failed primarily by gear tooth fracture while the forged and ausforged VIM-VAR AISI M-50 and the VAR AISI 9310 gears failed primarily by surface pitting fatigue. The ausforged gears had a slightly greater tendency to fail by tooth fracture than the standard forged gears.

  14. Ion release and cytotoxicity of stainless steel wires.

    PubMed

    Oh, Keun-Taek; Kim, Kyoung-Nam

    2005-12-01

    Heat treatment is generally applied to orthodontic stainless steel (SS) wires to relieve the stresses that result from their manipulation by orthodontists. The quality and thickness of the oxide films formed on the surface of heat-treated wires can vary, and it is believed that these oxide films can influence the properties of heat-treated wires. The aim of this study was to investigate the influence of heat treatment and cooling methods on the amount of metal ions released and to examine the cytotoxicity of heat-treated wires. In this study, four types of SS wires (Remanium, Permachrome, Colboloy and Orthos) with a cross-sectional area of 0.41 x 0.56 mm were investigated. These wires were heat-treated in a vacuum, air, or argon environment, and were cooled in either a furnace or a water bath. Four control groups and 24 experimental groups were classified according to the type of wires, heat treatment conditions and cooling methods. In each group, the amount of nickel released as well as its cytotoxicity was investigated. The concentration of dissolved nickel ions in artificial saliva was measured for a period of up to 12 weeks. In all groups, the concentration of dissolved nickel ions in artificial saliva was lowest for the vacuum heat treatment-furnace cooling group and a significant difference was shown compared with the other experimental groups. The concentration of dissolved nickel ions in artificial saliva was highest in the groups heat-treated in air (P < 0.05), while the amount of nickel released was highest in the Remanium and Colboloy (P < 0.05). The cytotoxicity was mild in all the experimental groups but the response index of the air groups was slightly higher than in the other groups. According to these results, SS wires retain their high corrosion resistance and low ion release rate when heat-treated in a vacuum and cooled in a furnace.

  15. Short-term effects of vacuum massage on epidermal and dermal thickness and density in burn scars: an experimental study.

    PubMed

    Meirte, Jill; Moortgat, Peter; Anthonissen, Mieke; Maertens, Koen; Lafaire, Cynthia; De Cuyper, Lieve; Hubens, Guy; Van Daele, Ulrike

    2016-01-01

    Vacuum massage is a non-invasive mechanical massage technique invented to treat burns and scars. To date, no effects of vacuum massage on thickness and density of human scar tissue have been reported. The process in which external stimuli are converted into biochemical responses in the cell is known as mechanotransduction. In the skin endothelial cells, fibroblasts and myofibroblasts embedded in the extracellular matrix (ECM) sense mechanical stimuli (created by vacuum massage) and may promote intracellular processes leading to matrix remodelling. Since mechanotransduction could be a plausible working mechanism for vacuum massage as an anti-scarring therapy, this study aims to investigate the short-term effects of vacuum massage on thickness and density of epidermis and dermis in burn scars in order to find proof of ECM remodelling. A one group experimental study was performed. Patients with burn scars on upper extremities, lower extremities, and trunk were recruited for participation in this study. The DUB®cutis 22 MHz ultrasound scanner was used to assess thickness and density of the epidermal and dermal skin layers. After baseline measurements, vacuum massage was performed according to a pre-defined protocol. Measurements were carried out at 5 min, 30 min, 1 h, and 2 h post-intervention. Thirteen scar sites from 9 different patients were investigated. In 8 out of the 13 scar sites, a disruption of the epidermis was noticed after the vacuum massage. Five minutes after the intervention, epidermal density decreased statistically significantly (p = .022) and dermal thickness increased (p = .018). Both changes lasted for more than 1 h, but after 2 h, the changes were no longer statistically significant. Dermal density decreased significantly (p = .048) immediately after the intervention, and this decrease was still present after 2 h (p = .011). Preliminary results show that the disruption of the epidermis may indicate that vacuum massage could be able to actually breach the skin barrier. The statistically significant changes in the dermal layers could suggest an increased ECM production after vacuum massage.

  16. Antibiotic prophylaxis for operative vaginal delivery.

    PubMed

    Liabsuetrakul, T; Choobun, T; Peeyananjarassri, K; Islam, M

    2004-01-01

    Vacuum and forceps assisted vaginal deliveries are reported to increase the incidence of postpartum infections and maternal readmission to hospital compared to spontaneous vaginal delivery. Prophylactic antibiotics are prescribed to prevent these infections. However, the benefit of antibiotic prophylaxis for operative vaginal deliveries is still unclear. To assess the effectiveness and safety of antibiotic prophylaxis in reducing infectious puerperal morbidities in women undergoing operative vaginal deliveries including vacuum and/or forceps deliveries. We searched the Cochrane Pregnancy and Childbirth Group trials register (November 2003), the Cochrane Central Register of Controlled Trials (The Cochrane Library, Issue 4, 2003) and MEDLINE (1966 to November 2003). All randomised trials comparing any prophylactic antibiotic regimens with placebo or no treatment in women undergoing vacuum or forceps deliveries were eligible. Participants were all pregnant women without evidence of infections or other indications for antibiotics of any gestational age undergoing vacuum or forceps delivery for any indications. Interventions were any antibiotic prophylaxis (any dosage regimen, any route of administration or at any time during delivery or the puerperium) compared with either placebo or no treatment. Four reviewers assessed trial eligibility and methodological quality. Two reviewers extracted the data independently using prepared data extraction forms. Any discrepancies were resolved by discussion and a consensus reached through discussion with all reviewers. We assessed methodological quality of the included trial using the standard Cochrane criteria and the CONSORT statement of randomised controlled trials. We calculated the relative risks using a fixed effect model and all the reviewers interpreted and discussed the results. One trial, involving 393 women undergoing either vacuum or forceps deliveries, was included. This trial identified only two out of the nine outcomes specified in this review. It reported seven women with endomyometritis in the group given no antibiotic and none in prophylactic antibiotic group. This difference did not reach statistical significance, but the relative risk reduction was 93% (relative risks 0.07; 95% confidence interval (CI) 0.00 to 1.21). There was no difference in the length of hospital stay between the two groups (weighted mean difference 0.09 days; 95% CI -0.23 to 0.41). The data were too few and of insufficient quality to make any recommendations for practice. Future research on antibiotic prophylaxis for operative vaginal delivery is needed to conclude whether it is useful for reducing postpartum morbidity.

  17. Simultaneous phylogeny reconstruction and multiple sequence alignment

    PubMed Central

    Yue, Feng; Shi, Jian; Tang, Jijun

    2009-01-01

    Background A phylogeny is the evolutionary history of a group of organisms. To date, sequence data is still the most used data type for phylogenetic reconstruction. Before any sequences can be used for phylogeny reconstruction, they must be aligned, and the quality of the multiple sequence alignment has been shown to affect the quality of the inferred phylogeny. At the same time, all the current multiple sequence alignment programs use a guide tree to produce the alignment and experiments showed that good guide trees can significantly improve the multiple alignment quality. Results We devise a new algorithm to simultaneously align multiple sequences and search for the phylogenetic tree that leads to the best alignment. We also implemented the algorithm as a C program package, which can handle both DNA and protein data and can take simple cost model as well as complex substitution matrices, such as PAM250 or BLOSUM62. The performance of the new method are compared with those from other popular multiple sequence alignment tools, including the widely used programs such as ClustalW and T-Coffee. Experimental results suggest that this method has good performance in terms of both phylogeny accuracy and alignment quality. Conclusion We present an algorithm to align multiple sequences and reconstruct the phylogenies that minimize the alignment score, which is based on an efficient algorithm to solve the median problems for three sequences. Our extensive experiments suggest that this method is very promising and can produce high quality phylogenies and alignments. PMID:19208110

  18. Color confinement from fluctuating topology

    DOE PAGES

    Kharzeev, Dmitri E.

    2016-10-19

    QCD possesses a compact gauge group, and this implies a non-trivial topological structure of the vacuum. In this contribution to the Gribov-85 Memorial volume, we first discuss the origin of Gribov copies and their interpretation in terms of fluctuating topology in the QCD vacuum. We then describe the recent work with E. Levin that links the confinement of gluons and color screening to the fluctuating topology, and discuss implications for spin physics, high energy scattering, and the physics of quark-gluon plasma.

  19. Changes in coronal alignment of the ankle joint after high tibial osteotomy.

    PubMed

    Choi, Gi Won; Yang, Jae Hyuk; Park, Jung Ho; Yun, Ho Hyun; Lee, Yong In; Chae, Jin Eon; Yoon, Jung Ro

    2017-03-01

    The purpose of this study was to investigate changes in coronal alignment of the ankle joint after HTO. Our hypothesis was that ankle joint orientation may become more parallel or less parallel to the ground after HTO, and this change may affect ankle symptoms. Eighty-six knees were retrospectively analysed after HTO for varus osteoarthritis. Preoperative and follow-up whole-leg radiographs were taken. The hip-knee-ankle (HKA) angle and medial proximal tibial angle (MPTA) were measured to evaluate coronal alignment of the knee. Tibial plafond inclination (TPI), talar inclination (TI), talar tilt (TT), and lateral distal tibial angle (LDTA) were measured to evaluate coronal alignment of the ankle. Patients were divided into two groups: those who exhibited a decrease in the absolute value of TPI and TI after HTO (group A) and those who exhibited an increase in the absolute value of TPI or TI after HTO (group B). Clinical outcomes of the knee and ankle were evaluated pre- and postoperatively. Mean TPI and TI changed from 6.9° ± 3.6° and 8.0° ± 3.8° to 2.8° ± 3.1° and 3.9° ± 3.0° in group A (P < 0.001 for both) and from -1.3° ± 3.7° and 0.6° ± 4.5° to -6.0° ± 4.2° and -4.6° ± 5.9° in group B (P = 0.018 for both). VAS for ankle pain did not change significantly after HTO (n.s.) in group A, whereas those of group B increased significantly after HTO (P = 0.014). Ankle joint orientation becomes more parallel or less parallel to the ground after HTO. Smaller preoperative HKA and LDTA result in a more valgus ankle joint orientation after HTO. Ankle symptoms were affected by coronal alignment changes of the ankle after HTO. III.

  20. Association of low back pain with muscle stiffness and muscle mass of the lumbar back muscles, and sagittal spinal alignment in young and middle-aged medical workers.

    PubMed

    Masaki, Mitsuhiro; Aoyama, Tomoki; Murakami, Takashi; Yanase, Ko; Ji, Xiang; Tateuchi, Hiroshige; Ichihashi, Noriaki

    2017-11-01

    Muscle stiffness of the lumbar back muscles in low back pain (LBP) patients has not been clearly elucidated because quantitative assessment of the stiffness of individual muscles was conventionally difficult. This study aimed to examine the association of LBP with muscle stiffness assessed using ultrasonic shear wave elastography (SWE) and muscle mass of the lumbar back muscle, and spinal alignment in young and middle-aged medical workers. The study comprised 23 asymptomatic medical workers [control (CTR) group] and 9 medical workers with LBP (LBP group). Muscle stiffness and mass of the lumbar back muscles (lumbar erector spinae, multifidus, and quadratus lumborum) in the prone position were measured using ultrasonic SWE. Sagittal spinal alignment in the standing and prone positions was measured using a Spinal Mouse. The association with LBP was investigated by multiple logistic regression analysis with a forward selection method. The analysis was conducted using the shear elastic modulus and muscle thickness of the lumbar back muscles, and spinal alignment, age, body height, body weight, and sex as independent variables. Multiple logistic regression analysis showed that muscle stiffness of the lumbar multifidus muscle and body height were significant and independent determinants of LBP, but that muscle mass and spinal alignment were not. Muscle stiffness of the lumbar multifidus muscle in the LBP group was significantly higher than that in the CTR group. The results of this study suggest that LBP is associated with muscle stiffness of the lumbar multifidus muscle in young and middle-aged medical workers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial.

    PubMed

    Aydın, Burcu; Şenışık, Neslihan Ebru; Koşkan, Özgür

    2018-05-01

    The aim of this trial was to compare the alignment efficiency and intermaxillary arch dimension changes of nickel-titanium (NiTi) or copper-nickel-titanium (CuNiTi) round archwires with increasing diameters applied sequentially to the mandibular arch. The initial alignment phase of fixed orthodontic treatment with NiTi or CuNiTi round archwires was studied in a randomly allocated sample of 66 patients. The NiTi group comprised 26 women, 10 men, and the CuNiTi (27℃) group comprised 20 women, 10 men. The eligibility criteria were as follows: anterior mandibular crowding of minimum 6 mm according to Little's Irregularity Index (LII), treatment requiring no extraction of premolars, 12 to 18 years of age, permanent dentition, skeletal and dental Class I malocclusion. The main outcome measure was the alignment of the mandibular anterior dentition; the secondary outcome measure was the change in mandibular dental arch dimensions during 12 weeks. Simple randomization (allocation ratio 1:1) was used in this single-blind study. LII and mandibular arch dimensions were measured on three-dimensional digital dental models at 2-week intervals. No statistically significant difference was observed between NiTi and CuNiTi according to LII ( p > 0.05). Intercanine and intermolar arch perimeters increased in the CuNiTi group ( p < 0.001). Inter-first premolar width showed a statistically significant interaction in week × diameter × application ( p < 0.05). The effects of NiTi and CuNiTi round archwires were similar in terms of their alignment efficiency. However, the intercanine and intermolar arch perimeters, and the inter-first premolar width changes differed between groups.

  2. A Molecular Phylogeny of the Chalcidoidea (Hymenoptera)

    PubMed Central

    Munro, James B.; Heraty, John M.; Burks, Roger A.; Hawks, David; Mottern, Jason; Cruaud, Astrid; Rasplus, Jean-Yves; Jansta, Petr

    2011-01-01

    Chalcidoidea (Hymenoptera) are extremely diverse with more than 23,000 species described and over 500,000 species estimated to exist. This is the first comprehensive phylogenetic analysis of the superfamily based on a molecular analysis of 18S and 28S ribosomal gene regions for 19 families, 72 subfamilies, 343 genera and 649 species. The 56 outgroups are comprised of Ceraphronoidea and most proctotrupomorph families, including Mymarommatidae. Data alignment and the impact of ambiguous regions are explored using a secondary structure analysis and automated (MAFFT) alignments of the core and pairing regions and regions of ambiguous alignment. Both likelihood and parsimony approaches are used to analyze the data. Overall there is no impact of alignment method, and few but substantial differences between likelihood and parsimony approaches. Monophyly of Chalcidoidea and a sister group relationship between Mymaridae and the remaining Chalcidoidea is strongly supported in all analyses. Either Mymarommatoidea or Diaprioidea are the sister group of Chalcidoidea depending on the analysis. Likelihood analyses place Rotoitidae as the sister group of the remaining Chalcidoidea after Mymaridae, whereas parsimony nests them within Chalcidoidea. Some traditional family groups are supported as monophyletic (Agaonidae, Eucharitidae, Encyrtidae, Eulophidae, Leucospidae, Mymaridae, Ormyridae, Signiphoridae, Tanaostigmatidae and Trichogrammatidae). Several other families are paraphyletic (Perilampidae) or polyphyletic (Aphelinidae, Chalcididae, Eupelmidae, Eurytomidae, Pteromalidae, Tetracampidae and Torymidae). Evolutionary scenarios discussed for Chalcidoidea include the evolution of phytophagy, egg parasitism, sternorrhynchan parasitism, hypermetamorphic development and heteronomy. PMID:22087244

  3. Density Functional Theory Calculation of the Band Alignment of (101̅0) In(x)Ga(1-x)N/Water Interfaces.

    PubMed

    Meng, Andrew C; Cheng, Jun; Sprik, Michiel

    2016-03-03

    Conduction band edge (CBE) and valence band edge (VBE) positions of InxGa1-xN photoelectrodes were computed using density functional theory methods. The band edges of fully solvated GaN and InN model systems were aligned with respect to the standard hydrogen electrode using a molecular dynamics hydrogen electrode scheme applied earlier to TiO2/water interfaces. Similar to the findings for TiO2, we found that the Purdew-Burke-Ernzerhof (PBE) functional gives a VBE potential which is too negative by 1 V. This cathodic bias is largely corrected by application of the Heyd-Scuseria-Ernzerhof (HSE06) hybrid functional containing a fraction of Hartree-Fock exchange. The effect of a change of composition was investigated using simplified model systems consisting of vacuum slabs covered on both sides by one monolayer of H2O. The CBE was found to vary linearly with In content. The VBE, in comparison, is much less sensitive to composition. The data show that the band edges straddle the hydrogen and oxygen evolution potentials for In fractions less than 47%. The band gap was found to exceed 2 eV for an In fraction less than 54%.

  4. Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker.

    PubMed

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2016-01-01

    To compare the accuracy of two different methods of preoperative marking for toric intraocular lens (IOL) implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for the final alignment of the toric IOL to achieve an outcome as close as possible to emmetropia. Toric IOLs were implanted in 180 eyes of 110 patients. One group (55 patients) had preoperative marking of both eyes done with bubble marker (ASICO AE-2791TBL) and the other group (55 patients) with pendulum marker (Rumex(®)3-193). Reference marks were placed at 3-, 6-, and 9-o'clock positions on the limbus. Slit-lamp photographs were analyzed using Adobe Photoshop (version 7.0). Amount of alignment error (in degrees) induced in each group was measured. Mean absolute rotation error in the preoperative marking in the horizontal axis was 2.42±1.71 in the bubble marker group and 2.83±2.31in the pendulum marker group (P=0.501). Sixty percent of the pendulum group and 70% of the bubble group had rotation error ≤3 (P=0.589), and 90% eyes of the pendulum group and 96.7% of the bubble group had rotation error ≤5 (P=0.612). Both preoperative marking techniques result in approximately 3 of alignment error. Both marking techniques are simple, predictable, reproducible and easy to perform.

  5. Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents

    PubMed Central

    Sánchez-Turrión, Andrés; López-Lozano, José F.; Albaladejo, Alberto; Torres-Lagares, Daniel; Montero, Javier; Suárez-García, Maria J.

    2012-01-01

    Objectives. This study aimed to evaluate the vertical discrepancy of implant-supported crown structures constructed with vacuum-casting and Direct Metal Laser Sintering (DMLS) technologies, and luted with different cement types. Study Design. Crown copings were fabricated using: (1) direct metal laser sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC); and (3) vacuum-cast Ti (CT). Frameworks were luted onto machined implant abutments under constant seating pressure. Each alloy group was randomly divided into 5 subgroups (n = 10 each) according to the cement system utilized: Subgroup 1 (KC) used resin-modified glass-ionomer Ketac Cem Plus; Subgroup 2 (PF) used Panavia F 2.0 dual-cure resin cement; Subgroup 3 (RXU) used RelyX Unicem 2 Automix self-adhesive dual-cure resin cement; Subgroup 4 (PIC) used acrylic/urethane-based temporary Premier Implant Cement; and Subgroup 5 (DT) used acrylic/urethane-based temporary DentoTemp cement. Vertical misfit was measured by scanning electron microscopy (SEM). Two-way ANOVA and Student-Newman-Keuls tests were run to investigate the effect of alloy/fabrication technique, and cement type on vertical misfit. The statistical significance was set at α = 0.05. Results. The alloy/manufacturing technique and the luting cement affected the vertical discrepancy (p < 0.001). For each cement type, LS samples exhibited the best fit (p < 0.01) whereas CC and CT frames were statistically similar. Within each alloy group, PF and RXU provided comparably greater discrepancies than KC, PIC, and DT, which showed no differences. Conclusions. Laser sintering may be an alternative to vacuum-casting of base metals to obtain passive-fitting implant-supported crown copings. The best marginal adaptation corresponded to laser sintered structures luted with glass-ionomer KC, or temporary PIC or DT cements. The highest discrepancies were recorded for Co-Cr and Ti cast frameworks bonded with PF or RXU resinous agents. All groups were within the clinically acceptable misfit range. Key words:Dental alloy, laser sintering, implant-supported prostheses, vertical discrepancy, vertical misfit. PMID:22322524

  6. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome

    PubMed Central

    Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-01-01

    Introduction Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. Aim To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. Materials and Methods In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Results Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian’s criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Conclusion Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA/B fractures without increasing the risk of infection. It gives better stability to fracture site and lessen the risk of implant failure. PMID:27042541

  7. Variable frequency matching to a radiofrequency source immersed in vacuum

    NASA Astrophysics Data System (ADS)

    Charles, C.; Boswell, R. W.; Bish, A.

    2013-09-01

    A low-weight (0.12 kg) low-volume fixed ceramic capacitor impedance matching system is developed for frequency agile tuning of a radiofrequency (rf) Helicon plasma thruster. Three fixed groups of capacitors are directly mounted onto a two loop rf antenna with the thruster immersed in a vacuum chamber. Optimum plasma tuning at the resonance frequency is demonstrated via measurements of the load impedance, power transfer efficiency and plasma density versus driving frequency in the 12.882-14.238 MHz range. The resonance frequency with the plasma on is higher than the resonance frequency in vacuum. The minimum rf power necessary for ignition decreases when the ignition frequency is shifted downwards from the resonance frequency. This development has direct applications in space qualification and space use of rf plasma thrusters.

  8. Thermocouples of tantalum and rhenium alloys for more stable vacuum-high temperature performance

    NASA Technical Reports Server (NTRS)

    Morris, J. F. (Inventor)

    1977-01-01

    Thermocouples of the present invention provide stability and performance reliability in systems involving high temperatures and vacuums by employing a bimetallic thermocouple sensor wherein each metal of the sensor is selected from a group of metals comprising tantalum and rhenium and alloys containing only those two metals. The tantalum, rhenium thermocouple sensor alloys provide bare metal thermocouple sensors having advantageous vapor pressure compatibilities and performance characteristics. The compatibility and physical characteristics of the thermocouple sensor alloys of the present invention result in improved emf, temperature properties and thermocouple hot junction performance. The thermocouples formed of the tantalum, rhenium alloys exhibit reliability and performance stability in systems involving high temperatures and vacuums and are adaptable to space propulsion and power systems and nuclear environments.

  9. National Ignition Facility Target Chamber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wavrik, R W; Cox, J R; Fleming, P J

    2000-10-05

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The twomore » isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This was necessary to achieve the overall schedule. Plans had to be developed for the precise location and alignment of laser beam ports. Upon completion of the fabrication of the aluminum target chamber in a temporary structure the 130 ton sphere was moved from the temporary construction enclosure to its final location in the target building. Prior to the installation of a concrete shield and after completion of the welding of the chamber penetrations vacuum leak checking was performed to insure the vacuum integrity of target chamber. The entire spherical chamber external surface supports a 40 cm thick reinforced concrete shield after installation in the target building. The final task is a total survey of the laser ports and the contour machining of spacer plates so that laser devices attached to these ports meet the alignment criteria.« less

  10. Capillary filtration in venous hypertension. Comparison between the vacuum suction chamber (VSC) device and straingauge phlethysmography.

    PubMed

    Belcaro, G; Rulo, A; Renton, S

    1992-01-01

    To evaluate capillary filtration a group of normal subjects and two groups of subjects with venous incompetence (50 with deep and 50 with superficial incompetence) were studied with the vacuum suction chamber (VSC) device applied onto the internal perimalleolar region. This method was compared with straingauge plethysmography rate of ankle swelling (RAS). By the VSC the time taken for the weal to disappear (VSC time) was considered indicative of capillary filtration. The values obtained with the two methods were well related (r < 0.742) and there was a good separation between patients and normals. The separation between the two groups of patients was significantly better (p < 0.05) with the VSC time. In conclusion VSC time is a good indication of capillary filtration in comparison with straingauge plethysmography RAS. It may be used to assess variations in capillary filtration in venous hypertension and possibly to follow up the effects of treatments.

  11. Photon number dependent group velocity in vacuum induced transparency

    NASA Astrophysics Data System (ADS)

    Lauk, Nikolai; Fleischhauer, Michael

    2015-05-01

    Vacuum induced transparency (VIT) is an effect which occurs in an ensemble of three level atoms in a Λ configuration that interact with two quantized fields. Coupling of one transition to a cavity mode induces transparency for the second field on the otherwise opaque transition similar to the well known EIT effect. In the strong coupling regime even an empty cavity leads to transparency, in contrast to EIT where the presence of a strong control field is required. This transparency is accompanied by a reduction of the group velocity for the propagating field. However, unlike in EIT the group velocity in VIT depends on the number of incoming photons, i.e. different photon number components propagate with different velocities. Here we investigate the possibility of using this effect to spatially separate different photon number components of an initially coherent pulse. We present the results of our calculations and discuss a possible experimental realization.

  12. A review of vacuum insulation research and development in the Building Materials Group of the Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kollie, T.G.; McElroy, D.L.; Fine, H.A.

    This report is a summary of the development work on flat-vacuum insulation performed by the Building Materials Group (BMG) in the Metals and Ceramics Division of the Oak Ridge National Laboratory (ORNL) during the last two years. A historical review of the technology of vacuum insulation is presented, and the role that ORNL played in this development is documented. The ORNL work in vacuum insulation has been concentrated in Powder-filled Evacuated Panels (PEPs) that have a thermal resistivity over 2.5 times that of insulating foams and seven times that of many batt-type insulations, such as fiberglass. Experimental results of substitutingmore » PEPs for chlorofluorocarbon (CFC) foal insulation in Igloo Corporation ice coolers are summarized. This work demonstrated that one-dimensional (1D) heat flow models overestimated the increase in thermal insulation of a foam/PEP-composite insulation, but three-dimensional (3D) models provided by a finite-difference, heat-transfer code (HEATING-7) accurately predicted the resistance of the composites. Edges and corners of the ice coolers were shown to cause the errors in the 1D models as well as shunting of the heat through the foam and around the PEPs. The area of coverage of a PEP in a foam/PEP composite is established as an important parameter in maximizing the resistance of such composites. 50 refs., 27 figs,. 22 tabs.« less

  13. Quality of Meat (Longissimus dorsi) from Male Fallow Deer (Dama dama) Packaged and Stored under Vacuum and Modified Atmosphere Conditions

    PubMed Central

    Piaskowska, N.; Daszkiewicz, T.; Kubiak, D.; Zapotoczny, P.

    2016-01-01

    This study evaluated the effect of vacuum and modified atmosphere (40% CO2+60% N2, MA) packaging on the chemical composition, physicochemical properties and sensory attributes of chill-stored meat from 10 fallow deer (Dama dama) bucks at 17 to 18 months of age. The animals were hunter-harvested in the forests of north-eastern Poland. During carcass dressing (48 to 54 h post mortem), both musculus longissimus muscles were cut out. Each muscle was divided into seven sections which were allocated to three groups: 0, A, and B. Samples 0 were immediately subjected to laboratory analyses. Samples A were vacuum-packaged, and samples B were packaged in MA. Packaged samples were stored for 7, 14, and 21 days at 2°C. The results of the present study showed that the evaluated packaging systems had no significant effect on the quality of fallow deer meat during chilled storage. However, vacuum-packaged meat samples were characterised by greater drip loss. Vacuum and MA packaging contributed to preserving the desired physicochemical properties and sensory attributes of meat during 21 days of storage. Regardless of the packaging method used, undesirable changes in the colour, water-holding capacity and juiciness of meat, accompanied by tenderness improvement, were observed during chilled storage. PMID:27165026

  14. Calibration results using highly aberrated images for aligning the JWST instruments to the telescope

    NASA Astrophysics Data System (ADS)

    Smith, Koby Z.; Acton, D. Scott; Gallagher, Ben B.; Knight, J. Scott; Dean, Bruce H.; Jurling, Alden S.; Zielinski, Thomas P.

    2016-07-01

    The James Webb Space Telescope (JWST) project is an international collaboration led by NASA's Goddard Space Flight Center (GSFC) in Greenbelt, MD. JWST is NASA's flagship observatory that will operate nearly a million miles away from Earth at the L2 Lagrange point. JWST's optical design is a three-mirror anastigmat with four main optical components; 1) the eighteen Primary Mirror Segment Assemblies (PMSA), 2) a single Secondary Mirror Assembly (SMA), 3) an Aft-Optics Subsystem (AOS) consisting of a Tertiary Mirror and Fine Steering Mirror, and 4) an Integrated Science Instrument Module consisting of the various instruments for JWST. JWST's optical system has been designed to accommodate a significant amount of alignment capability and risk with the PMSAs and SMA having rigid body motion available on-orbit just for alignment purposes. However, the Aft-Optics Subsystem (AOS) and Integrated Science Instrument Module (ISIM) are essentially fixed optical subsystems within JWST, and therefore the cryogenic alignment of the AOS to the ISIM is critical to the optical performance and mission success of JWST. In support of this cryogenic alignment of the AOS to ISIM, an array of fiber optic sources, known as the AOS Source Plate Assembly (ASPA), are placed near the intermediate image location of JWST (between the secondary and tertiary mirrors) during thermal vacuum ground-test operations. The AOS produces images of the ASPA fiber optic sources at the JWST focal surface location, where they are captured by the various science instruments. In this manner, the AOS provides an optical yardstick by which the instruments within ISIM can evaluate their relative positions to and the alignment of the AOS to ISIM can be quantified. However, since the ASPA is located at the intermediate image location of the JWST three-mirror anastigmat design, the images of these fiber optic sources produced by the AOS are highly aberrated with approximately 2-3μm RMS wavefront error consisting mostly of 3rd-order astigmatism and coma. This is because the elliptical tertiary mirror of the AOS is used off of its ideal foci locations without the compensating wavefront effects of the JWST primary and secondary mirrors. Therefore, the PSFs created are highly asymmetric with relatively complex structure and the centroid and encircled energy analyses traditionally used to locate images are not sufficient for ensuring the AOS to ISIM alignment. A novel approach combining phase retrieval and spatial metrology was developed to both locate the images with respect to the AOS and provide calibration information for eventual AOS to ISIM alignment verification. During final JWST OTE and ISIM (OTIS) testing, only a single thru-focus image will be collected by the instruments. Therefore, tools and processes were developed to perform single-image phase retrieval on these highly aberrated images such that any single image of the ASPA source can provide calibrated knowledge of the instruments' position relative to the AOS. This paper discusses the results of the methodology, hardware, and calibration performed to ensure that the AOS and ISIM are aligned within their respective tolerances at JWST OTIS testing.

  15. Calibration Issues and Operating System Requirements for Electron-Probe Microanalysis

    NASA Technical Reports Server (NTRS)

    Carpenter, P.

    2006-01-01

    Instrument purchase requirements and dialogue with manufacturers have established hardware parameters for alignment, stability, and reproducibility, which have helped improve the precision and accuracy of electron microprobe analysis (EPMA). The development of correction algorithms and the accurate solution to quantitative analysis problems requires the minimization of systematic errors and relies on internally consistent data sets. Improved hardware and computer systems have resulted in better automation of vacuum systems, stage and wavelength-dispersive spectrometer (WDS) mechanisms, and x-ray detector systems which have improved instrument stability and precision. Improved software now allows extended automated runs involving diverse setups and better integrates digital imaging and quantitative analysis. However, instrumental performance is not regularly maintained, as WDS are aligned and calibrated during installation but few laboratories appear to check and maintain this calibration. In particular, detector deadtime (DT) data is typically assumed rather than measured, due primarily to the difficulty and inconvenience of the measurement process. This is a source of fundamental systematic error in many microprobe laboratories and is unknown to the analyst, as the magnitude of DT correction is not listed in output by microprobe operating systems. The analyst must remain vigilant to deviations in instrumental alignment and calibration, and microprobe system software must conveniently verify the necessary parameters. Microanalysis of mission critical materials requires an ongoing demonstration of instrumental calibration. Possible approaches to improvements in instrument calibration, quality control, and accuracy will be discussed. Development of a set of core requirements based on discussions with users, researchers, and manufacturers can yield documents that improve and unify the methods by which instruments can be calibrated. These results can be used to continue improvements of EPMA.

  16. Fully constrained Majorana neutrino mass matrices using \\varvec{Σ(72× 3)}

    NASA Astrophysics Data System (ADS)

    Krishnan, R.; Harrison, P. F.; Scott, W. G.

    2018-01-01

    In 2002, two neutrino mixing ansatze having trimaximally mixed middle (ν _2) columns, namely tri-chi-maximal mixing ( {T}χ {M}) and tri-phi-maximal mixing ( {T}φ {M}), were proposed. In 2012, it was shown that {T}χ {M} with χ =± π /16 as well as {T}φ {M} with φ = ± π /16 leads to the solution, sin ^2 θ _{13} = 2/3 sin ^2 π /16, consistent with the latest measurements of the reactor mixing angle, θ _{13}. To obtain {T}χ {M}_{(χ =± π /16)} and {T}φ {M}_{(φ =± π /16)}, the type I see-saw framework with fully constrained Majorana neutrino mass matrices was utilised. These mass matrices also resulted in the neutrino mass ratios, m_1:m_2:m_3=( 2+√{2}) /1+√{2(2+√{2)}}:1:( 2+√{2}) /-1+√{2(2+√{2)}}. In this paper we construct a flavour model based on the discrete group Σ (72× 3) and obtain the aforementioned results. A Majorana neutrino mass matrix (a symmetric 3× 3 matrix with six complex degrees of freedom) is conveniently mapped into a flavon field transforming as the complex six-dimensional representation of Σ (72× 3). Specific vacuum alignments of the flavons are used to arrive at the desired mass matrices.

  17. Evolution of Structural and Optical Properties of ZnO Nanorods Grown on Vacuum Annealed Seed Crystallites

    PubMed Central

    Khan, Fasihullah; Ajmal, Hafiz Muhammad Salman; Huda, Noor Ul; Kim, Ji Hyun; Kim, Sam-Dong

    2018-01-01

    In this study, the ambient condition for the as-coated seed layer (SL) annealing at 350 °C is varied from air or nitrogen to vacuum to examine the evolution of structural and optical properties of ZnO nanorods (NRs). The NR crystals of high surface density (~240 rods/μm2) and aspect ratio (~20.3) show greatly enhanced (002) degree of orientation and crystalline quality, when grown on the SLs annealed in vacuum, compared to those annealed in air or nitrogen ambient. This is due to the vacuum-annealed SL crystals of a highly preferred orientation toward (002) and large grain sizes. X-ray photoelectron spectroscopy also reveals that the highest O/Zn atomic ratio of 0.89 is obtained in the case of vacuum-annealed SL crystals, which is due to the effective desorption of hydroxyl groups and other contaminants adsorbed on the surface formed during aqueous solution-based growth process. Near band edge emission (ultra violet range of 360–400 nm) of the vacuum-annealed SLs is also enhanced by 44% and 33% as compared to those annealed in air and nitrogen ambient, respectively, in photoluminescence with significant suppression of visible light emission associated with deep level transition. Due to this improvement of SL optical crystalline quality, the NR crystals grown on the vacuum-annealed SLs produce ~3 times higher ultra violet emission intensity than the other samples. In summary, it is shown that the ZnO NRs preferentially grow along the wurtzite c-axis direction, thereby producing the high crystalline quality of nanostructures when they grow on the vacuum-annealed SLs of high crystalline quality with minimized impurities and excellent preferred orientation. The ZnO nanostructures of high crystalline quality achieved in this study can be utilized for a wide range of potential device applications such as laser diodes, light-emitting diodes, piezoelectric transducers and generators, gas sensors, and ultraviolet detectors. PMID:29373523

  18. A natural S 4 × SO(10) model of flavour

    NASA Astrophysics Data System (ADS)

    Björkeroth, Fredrik; de Anda, Francisco J.; King, Stephen F.; Perdomo, Elena

    2017-10-01

    We propose a natural S 4 × SO(10) supersymmetric grand unified theory of flavour with an auxiliary Z_4^2× Z_4^R symmetry, based on small Higgs representations (nothing larger than an adjoint) and hence a type-I seesaw mechanism. The Yukawa structure of all fermions is determined by the hierarchical vacuum expectation values of three S 4 triplet flavons, with CSD3 vacuum alignments, where up-type quarks and neutrinos couple to one Higgs 10, and the down-type quarks and charged leptons couple to a second Higgs 10. The Yukawa matrices are obtained from sums of low-rank matrices, where each matrix in the sum naturally accounts for the mass of a particular family, as in sequential dominance in the neutrino sector, which predicts a normal neutrino mass hierarchy. The model accurately fits all available quark and lepton data, with predictions for the leptonic CP phase in 95% credible intervals given by 281° < δ ℓ < 308° and 225° < δ ℓ < 253°. The model reduces to the MSSM, with the two Higgs doublets emerging from the two Higgs 10s without mixing, and we demonstrate how a μ term of O(TeV) can be realised, as well as doublet-triplet splitting, with Planck scale operators controlled by symmetry, leading to acceptable proton decay.

  19. Method For Plasma Source Ion Implantation And Deposition For Cylindrical Surfaces

    DOEpatents

    Fetherston, Robert P. , Shamim, Muhammad M. , Conrad, John R.

    1997-12-02

    Uniform ion implantation and deposition onto cylindrical surfaces is achieved by placing a cylindrical electrode in coaxial and conformal relation to the target surface. For implantation and deposition of an inner bore surface the electrode is placed inside the target. For implantation and deposition on an outer cylindrical surface the electrode is placed around the outside of the target. A plasma is generated between the electrode and the target cylindrical surface. Applying a pulse of high voltage to the target causes ions from the plasma to be driven onto the cylindrical target surface. The plasma contained in the space between the target and the electrode is uniform, resulting in a uniform implantation or deposition of the target surface. Since the plasma is largely contained in the space between the target and the electrode, contamination of the vacuum chamber enclosing the target and electrodes by inadvertent ion deposition is reduced. The coaxial alignment of the target and the electrode may be employed for the ion assisted deposition of sputtered metals onto the target, resulting in a uniform coating of the cylindrical target surface by the sputtered material. The independently generated and contained plasmas associated with each cylindrical target/electrode pair allows for effective batch processing of multiple cylindrical targets within a single vacuum chamber, resulting in both uniform implantation or deposition, and reduced contamination of one target by adjacent target/electrode pairs.

  20. Chemical modification of corn fiber with ion-exchanging groups

    USDA-ARS?s Scientific Manuscript database

    Pretreated corn fiber was chemically modified with quaternary ammonium group or/and sulfonated with 3-chloro-2-hydroxypropanesulfonic acid under vacuum or at ambient pressure. The soluble fraction was dialyzed through 1 kDa MWCO dialysis tubing and the material retained inside the tubing was filtere...

  1. Intrapartum translabial ultrasound with pushing used to predict the difficulty in vacuum-assisted delivery of fetuses in non-occiput posterior position.

    PubMed

    Antonio Sainz, José; Borrero, Carlota; Aquise, Adriana; García-Mejido, José Antonio; Gutierrez, Laura; Fernández-Palacín, Ana

    2016-10-01

    Our aim is to evaluate the capacity of intrapartum translabial ultrasound (ITU) with pushing in the prediction of difficulty of fetal extraction in vacuum assisted deliveries. Prospective, observational study performed (2/2015-8/2015) on 75 nulliparous women, ≥37 weeks with singleton pregnancies at full dilatation who had ITU-with-pushing performed, previous to vacuum-placement for fetal extraction. Working on the translabial sagittal-plane, we assessed: Angle-Progression (AoP), Progression-Distance (PD) and Head-Direction (HD); in the axial plane we evaluated: Midline-Angle (MLA) and Head-Perineum-Distance (HPD). Vacuum extractions were classified as easy-difficulty (ED) (≤3 vacuum-pulls), difficult-unsuccessful (DD) (>3 vacuum-pulls). We did not assess occipito-posterior-presentations. Seventy nulliparous were studied (44-ED,26-DD). We observed no differences in obstetric, neonatal or intrapartum characteristics between the two study groups, with the following exceptions: newborn weight (3272 ± 438 g versus 3540 ± 372 g; p = 0.011) and number of vacuum-pulls (1.4-ED-vs-4.4-DD; p < 0.0005). AoP-pushing was 143.9° ± 14.6° in ED and 115.1°± 12.9° in DD (p < 0.0005); Head-Up was 79.5% versus 38.4% (p < 0.0005); PD-Pushing was 42.7 ± 11.3 mm versus 30.4 ± 9.8 mm (p < 0.0005); MLA-Pushing was 27.6°± 26.6° versus 57.5°±26.5°(p=0.025); HPD-Pushing was 40.8 ± 10.0 mm versus 47.4 ± 10.9 mm (p = 0.039). We identified that the presence of an AoP-Pushing > 128° predicts an Easy-Vacuum-Delivery (≤3 Vacuum-Pulls) in  >85% of cases (Sen 80%-FPR 9.3%).

  2. Feature-based Alignment of Volumetric Multi-modal Images

    PubMed Central

    Toews, Matthew; Zöllei, Lilla; Wells, William M.

    2014-01-01

    This paper proposes a method for aligning image volumes acquired from different imaging modalities (e.g. MR, CT) based on 3D scale-invariant image features. A novel method for encoding invariant feature geometry and appearance is developed, based on the assumption of locally linear intensity relationships, providing a solution to poor repeatability of feature detection in different image modalities. The encoding method is incorporated into a probabilistic feature-based model for multi-modal image alignment. The model parameters are estimated via a group-wise alignment algorithm, that iteratively alternates between estimating a feature-based model from feature data, then realigning feature data to the model, converging to a stable alignment solution with few pre-processing or pre-alignment requirements. The resulting model can be used to align multi-modal image data with the benefits of invariant feature correspondence: globally optimal solutions, high efficiency and low memory usage. The method is tested on the difficult RIRE data set of CT, T1, T2, PD and MP-RAGE brain images of subjects exhibiting significant inter-subject variability due to pathology. PMID:24683955

  3. Align-and-shine photolithography

    NASA Astrophysics Data System (ADS)

    Petrusis, Audrius; Rector, Jan H.; Smith, Kristen; de Man, Sven; Iannuzzi, Davide

    2009-10-01

    At the beginning of 2009, our group has introduced a new technique that allows fabrication of photolithographic patterns on the cleaved end of an optical fibre: the align-and-shine photolithography technique (see A. Petrušis et al., "The align-and-shine technique for series production of photolithography patterns on optical fibres", J. Micromech. Microeng. 19, 047001, 2009). Align-and-shine photolithography combines standard optical lithography with imagebased active fibre alignment processes. The technique adapts well to series production, opening the way to batch fabrication of fibre-top devices (D. Iannuzzi et al., "Monolithic fibre-top cantilever for critical environments and standard applications", Appl. Phys. Lett. 88, 053501, 2006) and all other devices that rely on suitable machining of engineered parts on the tip of a fibre. In this paper we review our results and briefly discuss its potential applications.

  4. Whole-proteome phylogeny of large dsDNA viruses and parvoviruses through a composition vector method related to dynamical language model

    PubMed Central

    2010-01-01

    Background The vast sequence divergence among different virus groups has presented a great challenge to alignment-based analysis of virus phylogeny. Due to the problems caused by the uncertainty in alignment, existing tools for phylogenetic analysis based on multiple alignment could not be directly applied to the whole-genome comparison and phylogenomic studies of viruses. There has been a growing interest in alignment-free methods for phylogenetic analysis using complete genome data. Among the alignment-free methods, a dynamical language (DL) method proposed by our group has successfully been applied to the phylogenetic analysis of bacteria and chloroplast genomes. Results In this paper, the DL method is used to analyze the whole-proteome phylogeny of 124 large dsDNA viruses and 30 parvoviruses, two data sets with large difference in genome size. The trees from our analyses are in good agreement to the latest classification of large dsDNA viruses and parvoviruses by the International Committee on Taxonomy of Viruses (ICTV). Conclusions The present method provides a new way for recovering the phylogeny of large dsDNA viruses and parvoviruses, and also some insights on the affiliation of a number of unclassified viruses. In comparison, some alignment-free methods such as the CV Tree method can be used for recovering the phylogeny of large dsDNA viruses, but they are not suitable for resolving the phylogeny of parvoviruses with a much smaller genome size. PMID:20565983

  5. Dark energy, scalar singlet dark matter and the Higgs portal

    NASA Astrophysics Data System (ADS)

    Landim, Ricardo G.

    2018-05-01

    One of the simplest extensions of the Standard Model (SM) comprises the inclusion of a massive real scalar field, neutral under the SM gauge groups, to be a dark matter candidate. The addition of a dimension-six term into the potential of the scalar dark matter enables the appearance of a false vacuum that describes the cosmic acceleration. We show that the running of the singlet self-interaction and the Higgs portal coupling differs from the standard scalar singlet dark matter model. If we maintain a positive quartic coupling, it is also possible to describe the accelerated expansion of the Universe through a false vacuum with the addition of a dimension-eight interaction term. In this case, where the potential remains bounded from below at low energies, the false vacuum decay is highly suppressed.

  6. Usefulness of anterior cervical fusion using titanium interbody cage for treatment of cervical degenerative disease with preoperative segmental kyphosis

    PubMed Central

    Hosoi, Kunihiko; Tonomura, Hitoshi; Takatori, Ryota; Nagae, Masateru; Mikami, Yasuo; Osawa, Toru; Arai, Yuji; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2017-01-01

    Abstract Favorable bone fusion and clinical results have been reported for anterior cervical fusion (ACF) using titanium interbody cage (TIC). This method might induce postoperative subsidence and local kyphosis, but the relationship between radiological changes and preoperative local alignment is not known. The purpose of the present study is to investigate the impact of preoperative local alignment on the clinical and radiological outcomes of ACF using TIC. The study enrolled 36 patients (mean age 49.8 years) who underwent single-level ACF using TIC for cervical degenerative diseases. Patients were divided into 2 groups by preoperative segmental lordotic angle at the operative level: group L, ≥0° (n = 16); group K, <0° (n = 20). Clinical outcomes included recovery rate according to the Japanese Orthopaedic Association score and complication rates. Radiological assessment was conducted for the cervical and segmental lordotic angles, subsidence, and bone fusion. Mann–Whitney test and chi-square test were applied to compare the outcomes. The Japanese Orthopaedic Association score recovery rate was 77.2% in group L and 87.6% in group K, with no significant difference. No obvious complications were observed in any of the subjects. Mean cervical lordotic angles preoperatively and at last follow-up were 9.2 ± 9.5° and 11.3 ± 11.7°, respectively, in group L, and −1.3 ± 12.8° and 4.6 ± 13.3°, respectively, in group K. The mean segmental lordotic angles preoperatively and at last follow-up were 2.5 ± 2.2° and 2.6 ± 5.7°, respectively, in group L, and −4.5 ± 2.8° and −1.4 ± 5.8°, respectively, in group K. In group K, the cervical and segmental lordotic angles at the last follow-up were significantly greater than the preoperative angles. The change observed in group L was not significant. Subsidence of ≥3 mm was observed in 3 patients in group L and 4 patients in group K. None of the patients showed nonunion. Anterior cervical fusion using TIC provided favorable clinical results regardless of preoperative segmental alignment. Although postoperative subsidence and kyphotic changes are concerns in patients presenting segmental kyphosis, ACF using TIC corrected both the entire cervical spine and segmental alignment. The TIC is useful for correction of the cervical alignment for patients with cervical degenerative disease with local kyphotic changes. PMID:28796062

  7. The impact of proximal femoral morphology on failure strength with a mid-head resection short-stem hip arthroplasty.

    PubMed

    Olsen, Michael; Al Saied, Mohamed; Morison, Zachary; Sellan, Michael; Waddell, James P; Schemitsch, Emil H

    2014-12-01

    Mid-head resection short-stem hip arthroplasty is a conservative alternative to conventional total hip replacement and addresses proximal fixation challenges in patients not suitable for hip resurfacing. It is unclear whether proximal femoral morphology impacts the ultimate failure load of mid-head resection implanted femurs, thus the aim of this study was to investigate the effect of native neck-shaft angle (NSA) and coronal implant alignment on proximal femoral strength. In total, 36 synthetic femurs with two different proximal femoral morphologies were utilized in this study. Of them, 18 femurs with a varus NSA of 120° and 18 femurs with a valgus NSA of 135° were each implanted with a mid-head resection prosthesis. Femurs within the two different femoral morphology groups were divided into three equal coronal implant alignment groups: 10° valgus, 10° varus or neutral alignment. Prepared femurs were tested for stiffness and to failure in axial compression. There was no significant difference in stiffness nor failure load between femurs implanted with valgus-, varus- or neutrally aligned implants in femurs with a NSA of 120° (p = 0.396, p = 0.111, respectively). Femurs implanted in valgus orientation were significantly stiffer and failed at significantly higher loads than those implanted in varus alignment in femurs with a NSA of 135° (p = 0.001, p = 0.007, respectively). A mid-head resection short-stem hip arthroplasty seems less sensitive to clinically relevant variations of coronal implant alignment and may be more forgiving upon implantation in some femoral morphologies, however, a relative valgus component alignment is recommended. © IMechE 2014.

  8. γ-Particle coincidence technique for the study of nuclear reactions

    NASA Astrophysics Data System (ADS)

    Zagatto, V. A. B.; Oliveira, J. R. B.; Allegro, P. R. P.; Chamon, L. C.; Cybulska, E. W.; Medina, N. H.; Ribas, R. V.; Seale, W. A.; Silva, C. P.; Gasques, L. R.; Zahn, G. S.; Genezini, F. A.; Shorto, J. M. B.; Lubian, J.; Linares, R.; Toufen, D. L.; Silveira, M. A. G.; Rossi, E. S.; Nobre, G. P.

    2014-06-01

    The Saci-Perere γ ray spectrometer (located at the Pelletron AcceleratorLaboratory - IFUSP) was employed to implement the γ-particle coincidence technique for the study of nuclear reaction mechanisms. For this, the 18O+110Pd reaction has been studied in the beam energy range of 45-54 MeV. Several corrections to the data due to various effects (energy and angle integrations, beam spot size, γ detector finite size and the vacuum de-alignment) are small and well controlled. The aim of this work was to establish a proper method to analyze the data and identify the reaction mechanisms involved. To achieve this goal the inelastic scattering to the first excited state of 110Pd has been extracted and compared to coupled channel calculations using the São Paulo Potential (PSP), being reasonably well described by it.

  9. Plasma assisted synthesis of vanadium pentoxide nanoplates

    NASA Astrophysics Data System (ADS)

    Singh, Megha; Sharma, Rabindar Kumar; Kumar, Prabhat; Reddy, G. B.

    2015-08-01

    In this work, we report the growth of α-V2O5 (orthorhombic) nanoplates on glass substrate using plasma assisted sublimation process (PASP) and Nickel as catalyst. 100 nm thick film of Ni is deposited over glass substrate by thermal evaporation process. Vanadium oxide nanoplates have been deposited treating vanadium metal foil under high vacuum conditions with oxygen plasma. Vanadium foil is kept at fixed temperature growth of nanoplates of V2O5 to take place. Samples grown have been studied using XPS, XRD and HRTEM to confirm the growth of α-phase of V2O5, which revealed pure single crystal of α- V2O5 in orthorhombic crystallographic plane. Surface morphological studies using SEM and TEM show nanostructured thin film in form of plates. Uniform, vertically aligned randomly oriented nanoplates of V2O5 have been deposited.

  10. Towards a complete Δ(27) × SO(10) GUT of flavour

    NASA Astrophysics Data System (ADS)

    Björkeroth, Fredrik

    2017-09-01

    We propose a renormalisable model based on Δ(27) family symmetry with an SO(10) grand unified theory (GUT) leading to a novel form of spontaneous geometrical CP violation. The symmetries are broken close to the GUT breaking scale to yield the minimal supersymmetric standard model with standard R-parity. Low-scale Yukawa structure is dictated by the coupling of matter to Δ(27) antitriplets \\bar φ whose vacuum expectation values are aligned in the CSD3 directions by the superpotential. Light physical Majorana neutrinos masses emerge from the seesaw mechanism within SO(10). The model predicts a normal neutrino mass hierarchy with the best-fit lightest neutrino mass m 1 ∼ 0.3 meV, CP-violating oscillation phase δl ≈ 280° and the remaining neutrino parameters all within 1σ of their best-fit experimental values.

  11. Design and control of a high precision drive mechanism

    NASA Astrophysics Data System (ADS)

    Pan, Bo; He, Yongqiang; Wang, Haowei; Zhang, Shuyang; Zhang, Donghua; Wei, Xiaorong; Jiang, Zhihong

    2017-01-01

    This paper summarizes the development of a high precision drive mechanism (HPDM) for space application, such as the directional antenna, the laser communication device, the mobile camera and other pointing mechanisms. In view of the great practical significance of high precision drive system, control technology for permanent magnet synchronous motor (PMSM) servo system is also studied and a PMSM servo controller is designed in this paper. And the software alignment was applied to the controller to eliminate the steady error of the optical encoder, which helps to realize the 1 arcsec (1σ) control precision. To assess its capabilities, the qualification environment testing including the thermal vacuum cycling testing, and the sinusoidal and random vibration were carried out. The testing results show that the performance of the HPDM is almost the same between the former and the end of each testing.

  12. A self-powered nano-photodetector based on PFH/ZnO nanorods organic/inorganic heterojunction

    NASA Astrophysics Data System (ADS)

    Li, Xiaoyun; Liu, Wei; Li, Peigang; Song, Jia; An, Yuehua; Shen, Jingqin; Wang, Shunli; Guo, Daoyou

    2018-03-01

    PFH/ZnO nanorods heterojunctions were fabricated by spin-coating p-type Poly (9,9-dihexylfluorene) (PFH) on n-type vertically aligned ZnO nanorod arrays grown by a facile hydrothermal method on indium tin oxide (ITO) transparent conductive glass. A typical p-n junction behavior was observed in the fabricated heterojunction. The current of heterojunction increases and decreases dramatically by switching the illumination on and off at zero bias, showing potential self-powered photodetector applications. The heterojunction were capable of generating negative current when illuminated under an appropriate wavelength. The photoresponse properties of the heterojunction can be tuned by the applied bias. In vacuum, the rectifying behavior disappeared, and show only simple semiconductor behavior. Band structure of the heterojunction was schematic drawn and explain the mechanism of the properties of PFH/ZnO nanorods heterojunctions.

  13. Spectral simulations of an axisymmetric force-free pulsar magnetosphere

    NASA Astrophysics Data System (ADS)

    Cao, Gang; Zhang, Li; Sun, Sineng

    2016-02-01

    A pseudo-spectral method with an absorbing outer boundary is used to solve a set of time-dependent force-free equations. In this method, both electric and magnetic fields are expanded in terms of the vector spherical harmonic (VSH) functions in spherical geometry and the divergence-free state of the magnetic field is enforced analytically by a projection method. Our simulations show that the Deutsch vacuum solution and the Michel monopole solution can be reproduced well by our pseudo-spectral code. Further, the method is used to present a time-dependent simulation of the force-free pulsar magnetosphere for an aligned rotator. The simulations show that the current sheet in the equatorial plane can be resolved well and the spin-down luminosity obtained in the steady state is in good agreement with the value given by Spitkovsky.

  14. A flexible skin patch for continuous physiological monitoring of mental disorders

    NASA Astrophysics Data System (ADS)

    Jang, Won Ick; Lee, Bong Kuk; Ryu, Jin Hwa; Baek, In-Bok; Yu, Han Young; Kim, Seunghwan

    2017-10-01

    In this study, we have newly developed a flexible adhesive skin patch of electrocardiogram (ECG) device for continuous physiological monitoring of mental disorders. In addition, this flexible patch did not cause any damage to the skin even after 24 hours attachment. We have also suggested the possibility of novel interconnection for copper film on polyimide and polydimethylsiloxane (PDMS) layers of the flexible patch. Self-align and soldering of IC chips such as resistor between metal pads on flexible skin patch have also successfully fabricated for 5 min at 180 °C in vacuum oven. Low temperature interconnection technology based on a Sn42/Bi58 solder was also developed for flexible ECG devices. As a result, we can monitor the mental health status through a comprehensive analysis of biological signals from flexible ECG devices.

  15. Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker

    PubMed Central

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2016-01-01

    AIM To compare the accuracy of two different methods of preoperative marking for toric intraocular lens (IOL) implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for the final alignment of the toric IOL to achieve an outcome as close as possible to emmetropia. METHODS Toric IOLs were implanted in 180 eyes of 110 patients. One group (55 patients) had preoperative marking of both eyes done with bubble marker (ASICO AE-2791TBL) and the other group (55 patients) with pendulum marker (Rumex®3-193). Reference marks were placed at 3-, 6-, and 9-o'clock positions on the limbus. Slit-lamp photographs were analyzed using Adobe Photoshop (version 7.0). Amount of alignment error (in degrees) induced in each group was measured. RESULTS Mean absolute rotation error in the preoperative marking in the horizontal axis was 2.42±1.71 in the bubble marker group and 2.83±2.31in the pendulum marker group (P=0.501). Sixty percent of the pendulum group and 70% of the bubble group had rotation error ≤3 (P=0.589), and 90% eyes of the pendulum group and 96.7% of the bubble group had rotation error ≤5 (P=0.612). CONCLUSION Both preoperative marking techniques result in approximately 3 of alignment error. Both marking techniques are simple, predictable, reproducible and easy to perform. PMID:27275425

  16. Additive manufacturing method for SRF components of various geometries

    DOEpatents

    Rimmer, Robert; Frigola, Pedro E; Murokh, Alex Y

    2015-05-05

    An additive manufacturing method for forming nearly monolithic SRF niobium cavities and end group components of arbitrary shape with features such as optimized wall thickness and integral stiffeners, greatly reducing the cost and technical variability of conventional cavity construction. The additive manufacturing method for forming an SRF cavity, includes atomizing niobium to form a niobium powder, feeding the niobium powder into an electron beam melter under a vacuum, melting the niobium powder under a vacuum in the electron beam melter to form an SRF cavity; and polishing the inside surface of the SRF cavity.

  17. Integration and Testing of the Lunar Reconnaissance Orbiter Attitude Control System

    NASA Technical Reports Server (NTRS)

    Simpson, Jim; Badgley, Jason; McCaughey, Ken; Brown, Kristen; Calhoun, Philip; Davis, Edward; Garrick, Joseph; Gill, Nathaniel; Hsu, Oscar; Jones, Noble; hide

    2010-01-01

    Throughout the Lunar Reconnaissance Orbiter (LRO) Integration and Testing (I&T) phase of the project, the Attitude Control System (ACS) team completed numerous tests on each hardware component in ever more flight like environments. The ACS utilizes a select group of attitude sensors and actuators. This paper chronicles the evolutionary steps taken to verify each component was constantly ready for flight as well as providing invaluable trending experience with the actual hardware. The paper includes a discussion of each ACS hardware component, lessons learned of the various stages of I&T, a discussion of the challenges that are unique to the LRO project, as well as a discussion of work for future missions to consider as part of their I&T plan. LRO ACS sensors were carefully installed, tested, and maintained over the 18 month I&T and prelaunch timeline. Care was taken with the optics of the Adcole Coarse Sun Sensors (CSS) to ensure their critical role in the Safe Hold mode was fulfilled. The use of new CSS stimulators provided the means of testing each CSS sensor independently, in ambient and vacuum conditions as well as over a wide range of thermal temperatures. Extreme bright light sources were also used to test the CSS in ambient conditions. The integration of the two SELEX Galileo Star Trackers was carefully planned and executed. Optical ground support equipment was designed and used often to check the performance of the star trackers throughout I&T in ambient and thermal/vacuum conditions. A late discovery of potential contamination of the star tracker light shades is discussed in this paper. This paper reviews how each time the spacecraft was at a new location and orientation, the Honeywell Miniature Inertial Measurement Unit (MIMU) was checked for data output validity. This gyro compassing test was performed at several key testing points in the timeline as well as several times while LRO was on the launch pad. Sensor alignment tests were completed several times to ensure that hardware remained on a rigid platform.

  18. Furnace assembly

    DOEpatents

    Panayotou, Nicholas F.; Green, Donald R.; Price, Larry S.

    1985-01-01

    A method of and apparatus for heating test specimens to desired elevated temperatures for irradiation by a high energy neutron source. A furnace assembly is provided for heating two separate groups of specimens to substantially different, elevated, isothermal temperatures in a high vacuum environment while positioning the two specimen groups symmetrically at equivalent neutron irradiating positions.

  19. Furnace assembly

    DOEpatents

    Panayotou, N.F.; Green, D.R.; Price, L.S.

    A method of and apparatus for heating test specimens to desired elevated temperatures for irradiation by a high energy neutron source. A furnace assembly is provided for heating two separate groups of specimens to substantially different, elevated, isothermal temperatures in a high vacuum environment while positioning the two specimen groups symmetrically at equivalent neutron irradiating positions.

  20. Correlation and Reliability of Cervical Sagittal Alignment Parameters between Lateral Cervical Radiograph and Lateral Whole-Body EOS Stereoradiograph.

    PubMed

    Singhatanadgige, Weerasak; Kang, Daniel G; Luksanapruksa, Panya; Peters, Colleen; Riew, K Daniel

    2016-09-01

    Retrospective analysis. To evaluate the correlation and reliability of cervical sagittal alignment parameters obtained from lateral cervical radiographs (XRs) compared with lateral whole-body stereoradiographs (SRs). We evaluated adults with cervical deformity using both lateral XRs and lateral SRs obtained within 1 week of each other between 2010 and 2014. XR and SR images were measured by two independent spine surgeons using the following sagittal alignment parameters: C2-C7 sagittal Cobb angle (SCA), C2-C7 sagittal vertical axis (SVA), C1-C7 translational distance (C1-7), T1 slope (T1-S), neck tilt (NT), and thoracic inlet angle (TIA). Pearson correlation and paired t test were used for statistical analysis, with intra- and interrater reliability analyzed using intraclass correlation coefficient (ICC). A total of 35 patients were included in the study. We found excellent intrarater reliability for all sagittal alignment parameters in both the XR and SR groups with ICC ranging from 0.799 to 0.994 for XR and 0.791 to 0.995 for SR. Interrater reliability was also excellent for all parameters except NT and TIA, which had fair reliability. We also found excellent correlations between XR and SR measurements for most sagittal alignment parameters; SCA, SVA, and C1-C7 had r > 0.90, and only NT had r < 0.70. There was a significant difference between groups, with SR having lower measurements compared with XR for both SVA (0.68 cm lower, p < 0.001) and C1-C7 (1.02 cm lower, p < 0.001). There were no differences between groups for SCA, T1-S, NT, and TIA. Whole-body stereoradiography appears to be a viable alternative for measuring cervical sagittal alignment parameters compared with standard radiography. XR and SR demonstrated excellent correlation for most sagittal alignment parameters except NT. However, SR had significantly lower average SVA and C1-C7 measurements than XR. The lower radiation exposure using single SR has to be weighed against its higher cost compared with XR.

  1. ‘He's going to be a doctor in August’: a narrative interview study of medical students' and their educators' experiences of aligned and misaligned assistantships

    PubMed Central

    Jones, Owen Meurig; Okeke, Chiemeka; Bullock, Alison; Wells, Stephanie E; Monrouxe, Lynn V

    2016-01-01

    Objective To explore final-year students’ and clinical supervisors’ experiences of alignment and misalignment with future Foundation Year 1 (F1) posts in an assistantship programme in the UK. Setting Assistantships are clinical placements in which students assist junior doctors by undertaking similar duties under supervision. Models of assistantship programmes vary across curricula. Some actively seek to align with students’ initial postgraduate F1 post. To date, no research has examined the implications of this association for teaching and learning. Qualitative individual and group narrative interviews were conducted with students and supervisors of 2 Welsh medical schools to address: RQ1: How do students and supervisors understand the purpose of the longitudinal assistantship? RQ2: Does alignment/misalignment of the assistantship with students’ initial F1 post influence students’ and supervisors’ teaching and learning experiences? Audio-recordings of interviews were transcribed, participants anonymised and framework analysis was used. Participants A convenience sample of 4 participant groups comprised (1) final-year medical students whose assistantship and F1 post were aligned (n=27), (2) final-year medical students whose assistantship and F1 post were misaligned (n=18) and (3) supervisors (n=10, junior doctors; n=11, consultants). Results All participant groups highlighted increased student confidence in undertaking the duties of an F1 doctor arising from their assistantship period. Learning transferable skills was also highlighted. Many students considered themselves to be team members, ‘learning the trade’ as they shadowed their F1. Opportunities for caring for acutely unwell patients were scarce. The evidence shows enhanced engagement for students aligned to their first F1 post with greater opportunities for workplace acclimatisation. Those who were misaligned were perceived as being disadvantaged. Conclusions Our findings suggest that alignment with students’ first F1 post enhances the assistantship experience. Further longitudinal assessment is required to examine whether and how this translates into improvements in functioning and reductions in stress and anxiety during this transitional period. PMID:27288387

  2. Evaluation of fit of cement-retained implant-supported 3-unit structures fabricated with direct metal laser sintering and vacuum casting techniques.

    PubMed

    Oyagüe, Raquel Castillo; Sánchez-Turrión, Andrés; López-Lozano, José Francisco; Montero, Javier; Albaladejo, Alberto; Suárez-García, María Jesús

    2012-07-01

    This study evaluated the vertical discrepancy of implant-fixed 3-unit structures. Frameworks were constructed with laser-sintered Co-Cr, and vacuum-cast Co-Cr, Ni-Cr-Ti, and Pd-Au. Samples of each alloy group were randomly luted in standard fashion using resin-modified glass-ionomer, self-adhesive, and acrylic/urethane-based cements (n = 12 each). Discrepancies were SEM analyzed. Three-way ANOVA and Student-Newman-Keuls tests were run (P < 0.05). Laser-sintered structures achieved the best fit per cement tested. Within each alloy group, resin-modified glass-ionomer and acrylic/urethane-based cements produced comparably lower discrepancies than the self-adhesive agent. The abutment position did not yield significant differences. All misfit values could be considered clinically acceptable.

  3. Systems Thinking and the Leadership Conundrum in Health Care

    ERIC Educational Resources Information Center

    Marchildon, Gregory P.; Fletcher, Amber J.

    2016-01-01

    The ability to think in terms of a system is critical to achieving common direction, alignment, and commitment in highly distributed health systems. In Canada, provincial and territorial ministries of health provide leadership on the direction of health reform while leadership to align system levels is determined by a far more distributed group of…

  4. Aligning English Language Testing with Curriculum

    ERIC Educational Resources Information Center

    Palacio, Marcela; Gaviria, Sandra; Brown, James Dean

    2016-01-01

    Frustrations with traditional testing led a group of teachers at the English for adults program at Universidad EAFIT (Colombia) to design tests aligned with the institutional teaching philosophy and classroom practices. This article reports on a study of an item-by-item evaluation of a series of English exams for validity and reliability in an…

  5. Comparison of Alignment Correction Angles Between Fixed-Bearing and Mobile-Bearing UKA.

    PubMed

    Inoue, Atsuo; Arai, Yuji; Nakagawa, Shuji; Inoue, Hiroaki; Yamazoe, Shoichi; Kubo, Toshikazu

    2016-01-01

    Good outcomes have been reported with both fixed-bearing and mobile-bearing unicompartmental knee arthroplasty (UKA). However, overcorrected alignment could induce the progression of arthritis on the non-arthroplasty side. Changes of limb alignment after UKA with both types of bearings (fixed bearing: 24 knees, mobile bearing: 28 knees) were investigated. The mean difference between the preoperative standing femoral-tibial angle (FTA) and postoperative standing FTA was significantly larger in mobile bearing UKA group. In fixed-bearing UKA, there must be some laxity in MCL tension so that a 2-mm tension gauge can be inserted. In mobile-bearing UKA, appropriate MCL tension is needed to prevent bearing dislocation. This difference in MCL tension may have caused the difference in the correction angle between the groups. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. On aggregation in CA models in biology

    NASA Astrophysics Data System (ADS)

    Alber, Mark S.; Kiskowski, Audi

    2001-12-01

    Aggregation of randomly distributed particles into clusters of aligned particles is modeled using a cellular automata (CA) approach. The CA model accounts for interactions between more than one type of particle, in which pressures for angular alignment with neighbors compete with pressures for grouping by cell type. In the case of only one particle type clusters tend to unite into one big cluster. In the case of several types of particles the dynamics of clusters is more complicated and for specific choices of parameters particle sorting occurs simultaneously with the formation of clusters of aligned particles.

  7. Antibiotic prophylaxis for operative vaginal delivery.

    PubMed

    Liabsuetrakul, Tippawan; Choobun, Thanapan; Peeyananjarassri, Krantarat; Islam, Q Monir

    2014-10-13

    Vacuum and forceps assisted vaginal deliveries are reported to increase the incidence of postpartum infections and maternal readmission to hospital compared to spontaneous vaginal delivery. Prophylactic antibiotics may be prescribed to prevent these infections. However, the benefit of antibiotic prophylaxis for operative vaginal deliveries is still unclear. To assess the effectiveness and safety of antibiotic prophylaxis in reducing infectious puerperal morbidities in women undergoing operative vaginal deliveries including vacuum or forceps deliveries, or both. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 August 2014). All randomised trials comparing any prophylactic antibiotic regimens with placebo or no treatment in women undergoing vacuum or forceps deliveries were eligible. Participants were all pregnant women without evidence of infections or other indications for antibiotics of any gestational age undergoing vacuum or forceps delivery for any indications. Interventions were any antibiotic prophylaxis (any dosage regimen, any route of administration or at any time during delivery or the puerperium) compared with either placebo or no treatment. Two review authors assessed trial eligibility and methodological quality. Two review authors extracted the data independently using prepared data extraction forms. Any discrepancies were resolved by discussion and a consensus reached through discussion with all review authors. For this update, we assessed methodological quality of the one included trial using the standard Cochrane criteria and the GRADE approach. We calculated the risk ratio (RR) and mean difference (MD) using a fixed-effect model and all the review authors interpreted and discussed the results. One trial, involving 393 women undergoing either vacuum or forceps deliveries, was included. This trial identified only two out of the nine outcomes specified in this review. It reported seven women with endomyometritis in the group given no antibiotic and none in prophylactic antibiotic group. This difference did not reach statistical significance, but the risk reduction was 93% (risk ratio (RR) 0.07; 95% confidence interval (CI) 0.00 to 1.21). There was no difference in the length of hospital stay between the two groups (mean difference (MD) 0.09 days; 95% CI -0.23 to 0.41). Overall, the risk of bias was judged as low. The quality of the evidence using GRADE was low for both endometritis and maternal length of stay. The data were too few to make any recommendations for practice. Future research on antibiotic prophylaxis for operative vaginal delivery is needed to conclude whether it is useful for reducing postpartum morbidity.

  8. Is the effectiveness of patellofemoral bracing modified by patellofemoral alignment and trochlear morphology?

    PubMed

    Zhang, Xi; Eyles, Jillian P; Makovey, Joanna; Williams, Matthew J; Hunter, David J

    2017-04-21

    This study was performed to determine if the effectiveness of patellofemoral bracing as a treatment for patellofemoral osteoarthritis is influenced by patellofemoral joint alignment and trochlear morphology. We hypothesized that those with more extreme patellar malalignment would benefit more from bracing. Thirty-eight patients who had received bracing as part of a comprehensive treatment plan for patellofemoral osteoarthritis were selected for this study. Ten measures of patellar alignment were taken from X-rays. These alignment measures were divided into percentile groups (tertiles) for contingency table analysis. Treatment outcome was measured by Western Ontario and Macmasters Universities Osteoarthritis Index (WOMAC) scores and these were dichotomised into two groups according to "Improved" or "Not Improved" according to the minimum clinically important difference (MCID). Spearman's rho test was performed for continuous variables and Fisher's exact test was performed for correlation between tertile groups and MCID categories. Thirty-eight patients (9 male and 29 female) between the ages of 51 to 89 were included in this study. WOMAC scores ranged from -25 to 41.67, with a mean change of -3.97, 31.6, 44.7 and 31.6% of patients falling into the "Improved" group for Global, Pain and Function scores respectively. We found a non-significant trend shown (p = 0.058, correlation coefficient 0.31) between bisect offset and change in WOMAC global, indicating a trend for higher change in WOMAC scores with increasing bisect offset. Statistically significant correlations were found between mean MCID categories for the WOMAC global and function groups when analysed against percentile groups for bisect offset (p < 0.01) and patellar subluxation distance (p < 0.05), indicating those in higher percentile groups were more likely not to improve after six months. Higher bisect offset and patellar subluxation distance measures were associated with poorer outcomes. However, due to the limited sample size, more studies are required to fully examine this relationship.

  9. Stiffness after total knee arthroplasty: does component alignment differ in knees requiring manipulation? A retrospective cohort study of 281 patients.

    PubMed

    Harvie, Paul; Larkin, James; Scaddan, Matt; Longstaff, Lee M; Sloan, Karen; Beaver, Richard J

    2013-01-01

    This study aims to evaluate component alignment in a large cohort of total knee arthroplasties (TKAs) and ascertain whether alignment in TKAs undergoing postoperative manipulation under anesthetic is significantly different from those achieving good function. A retrospective review of 281 consecutive primary TKAs was performed. All TKAs underwent computed tomographic scanning (Perth computed tomography knee protocol). Of 281 TKAs, 21 (7.4%) underwent manipulation, performed at a mean of 8.1 weeks (range, 3-14 weeks) after surgery. No statistically significant difference was seen between groups for any of 12 parameters of alignment. Postoperative stiffness with the need for manipulation under anesthetic is multifactorial in origin. This study found insufficient evidence to support the theory that component alignment contributes significantly to the etiology of this difficult problem. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  10. Multi-subject Manifold Alignment of Functional Network Structures via Joint Diagonalization.

    PubMed

    Nenning, Karl-Heinz; Kollndorfer, Kathrin; Schöpf, Veronika; Prayer, Daniela; Langs, Georg

    2015-01-01

    Functional magnetic resonance imaging group studies rely on the ability to establish correspondence across individuals. This enables location specific comparison of functional brain characteristics. Registration is often based on morphology and does not take variability of functional localization into account. This can lead to a loss of specificity, or confounds when studying diseases. In this paper we propose multi-subject functional registration by manifold alignment via coupled joint diagonalization. The functional network structure of each subject is encoded in a diffusion map, where functional relationships are decoupled from spatial position. Two-step manifold alignment estimates initial correspondences between functionally equivalent regions. Then, coupled joint diagonalization establishes common eigenbases across all individuals, and refines the functional correspondences. We evaluate our approach on fMRI data acquired during a language paradigm. Experiments demonstrate the benefits in matching accuracy achieved by coupled joint diagonalization compared to previously proposed functional alignment approaches, or alignment based on structural correspondences.

  11. The emergence of human prosociality: aligning with others through feelings, concerns, and norms

    PubMed Central

    Jensen, Keith; Vaish, Amrisha; Schmidt, Marco F. H.

    2014-01-01

    The fact that humans cooperate with nonkin is something we take for granted, but this is an anomaly in the animal kingdom. Our species’ ability to behave prosocially may be based on human-unique psychological mechanisms. We argue here that these mechanisms include the ability to care about the welfare of others (other-regarding concerns), to “feel into” others (empathy), and to understand, adhere to, and enforce social norms (normativity). We consider how these motivational, emotional, and normative substrates of prosociality develop in childhood and emerged in our evolutionary history. Moreover, we suggest that these three mechanisms all serve the critical function of aligning individuals with others: Empathy and other-regarding concerns align individuals with one another, and norms align individuals with their group. Such alignment allows us to engage in the kind of large-scale cooperation seen uniquely in humans. PMID:25120521

  12. A Randomized Controlled Trial Evaluating the See, Tilt, Align, and Rotate (STAR) Maneuver on Skill Acquisition for Simulated Ultrasound-Guided Interventional Procedures.

    PubMed

    Lam, Nicholas C K; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Gerstein, Neal S; Mariano, Edward R

    2015-06-01

    Achieving the best view of the needle and target anatomy when performing ultrasound-guided interventional procedures requires technical skill, which novices may find difficult to learn. We hypothesized that teaching novice performers to use 4 sequential steps (see, tilt, align, and rotate [STAR] method) to identify the needle under ultrasound guidance is more efficient than training with the commonly described probe movements of align, rotate, and tilt (ART). This study compared 2 instructional methods for transducer manipulation including alignment of a probe and needle by novices during a simulated ultrasound-guided nerve block. Right-handed volunteers between the ages of 18 and 55 years who had no previous ultrasound experience were recruited and randomized to 1 of 2 groups; one group was trained to troubleshoot misalignment with the ART method, and the other was trained with the new STAR maneuver. Participants performed the task, consisting of directing a needle in plane to 3 targets in a standardized gelatin phantom 3 times. The performance assessor and data analyst were blinded to group assignment. Thirty-five participants were recruited. The STAR group was able to complete the task more quickly (P < .001) and visualized the needle in a greater proportion of the procedure time (P = .004) compared to the ART group. All STAR participants were able to complete the task, whereas 41% of ART participants abandoned the task (P = .003). Novices are able to complete a simulated ultrasound-guided nerve block more quickly and efficiently when trained with the 4-step STAR maneuver compared to the ART method. © 2015 by the American Institute of Ultrasound in Medicine.

  13. Color Confinement and Screening in the θ Vacuum of QCD.

    PubMed

    Kharzeev, Dmitri E; Levin, Eugene M

    2015-06-19

    QCD perturbation theory ignores the compact nature of the SU(3) gauge group that gives rise to the periodic θ vacuum of the theory. We propose to modify the gluon propagator to reconcile perturbation theory with the anomalous Ward identities for the topological current in the θ vacuum. As a result, the gluon couples to the Veneziano ghost describing the tunneling transitions between different Chern-Simons sectors of the vacuum; we call the emerging gluon dressed by ghost loops a "glost." We evaluate the glost propagator and find that it has the form G(p)=(p(2)+χ(top)/p(2))(-1) where χ(top) is the Yang-Mills topological susceptibility related to the η' mass by the Witten-Veneziano relation; this propagator describes the confinement of gluons at distances ∼χ(top)(-1/4)≃1  fm. The same functional form of the propagator was originally proposed by Gribov as a solution to the gauge copies problem that plagues perturbation theory. The resulting running coupling coincides with the perturbative one at p(2)≫√[χ(top)], but in the infrared region either freezes (in pure Yang-Mills theory) or vanishes (in full QCD with light quarks), in accord with experimental evidence. Our scenario makes explicit the connection between confinement and topology of the QCD vacuum; we discuss the implications for spin physics, high energy scattering, and the physics of quark-gluon plasma.

  14. Cleaning devices

    NASA Technical Reports Server (NTRS)

    Schneider, Horst W. (Inventor)

    1981-01-01

    Cleaning devices are described which include a vacuum cleaner nozzle with a sharp rim for directing incoming air down against the floor; a vacuum cleaner wherein electrostatically charged brushes that brush dirt off a floor, are electrically grounded to remove charges that could tend to hold dirt to the brushes; a vacuum cleaner head having slots that form a pair of counter-rotating vortices, and that includes an outlet that blows a stream of air at the floor region which lies between the vortices; a cleaning device that sweeps a group of brushes against the ground along a first direction, and then sweeps them along the same ground area but in a second direction angled from the first by an amount such as 90.degree., to sweep up particles lying in crevices extending along any direction; a device that gently cleans a surface to remove bacteria for analysis, including an inclined wall along which cleaning fluid flows onto the surface, a vacuum chamber for drawing in the cleaning fluid, and a dividing wall spaced slightly from the surface to separate the fluid source from the vacuum cleaner chamber; and a device for providing pulses of pressured air including a chamber to which pressured air is supplied, a ball that circulates around the chamber to repeatedly close an outlet, and an air source that directs air circumferentially to move the ball around the chamber.

  15. On the alignment of cellulose microfibrils by cortical microtubules: a review and a model.

    PubMed

    Baskin, T I

    2001-01-01

    The hypothesis that microtubules align microfibrils, termed the alignment hypothesis, states that there is a causal link between the orientation of cortical microtubules and the orientation of nascent microfibrils. I have assessed the generality of this hypothesis by reviewing what is known about the relation between microtubules and microfibrils in a wide group of examples: in algae of the family Characeae, Closterium acerosum, Oocystis solitaria, and certain genera of green coenocytes and in land plant tip-growing cells, xylem, diffusely growing cells, and protoplasts. The salient features about microfibril alignment to emerge are as follows. Cellulose microfibrils can be aligned by cortical microtubules, thus supporting the alignment hypothesis. Alignment of microfibrils can occur independently of microtubules, showing that an alternative to the alignment hypothesis must exist. Microfibril organization is often random, suggesting that self-assembly is insufficient. Microfibril organization differs on different faces of the same cell, suggesting that microfibrils are aligned locally, not with respect to the entire cell. Nascent microfibrils appear to associate tightly with the plasma membrane. To account for these observations, I present a model that posits alignment to be mediated through binding the nascent microfibril. The model, termed templated incorporation, postulates that the nascent microfibril is incorporated into the cell wall by binding to a scaffold that is oriented; further, the scaffold is built and oriented around either already incorporated microfibrils or plasma membrane proteins, or both. The role of cortical microtubules is to bind and orient components of the scaffold at the plasma membrane. In this way, spatial information to align the microfibrils may come from either the cell wall or the cell interior, and microfibril alignment with and without microtubules are subsets of a single mechanism.

  16. MUSE field splitter unit: fan-shaped separator for 24 integral field units

    NASA Astrophysics Data System (ADS)

    Laurent, Florence; Renault, Edgard; Anwand, Heiko; Boudon, Didier; Caillier, Patrick; Kosmalski, Johan; Loupias, Magali; Nicklas, Harald; Seifert, Walter; Salaun, Yves; Xu, Wenli

    2014-07-01

    MUSE (Multi Unit Spectroscopic Explorer) is a second generation Very Large Telescope (VLT) integral field spectrograph developed for the European Southern Observatory (ESO). It combines a 1' x 1' field of view sampled at 0.2 arcsec for its Wide Field Mode (WFM) and a 7.5"x7.5" field of view for its Narrow Field Mode (NFM). Both modes will operate with the improved spatial resolution provided by GALACSI (Ground Atmospheric Layer Adaptive Optics for Spectroscopic Imaging), that will use the VLT deformable secondary mirror and 4 Laser Guide Stars (LGS) foreseen in 2015. MUSE operates in the visible wavelength range (0.465-0.93 μm). A consortium of seven institutes is currently commissioning MUSE in the Very Large Telescope for the Preliminary Acceptance in Chile, scheduled for September, 2014. MUSE is composed of several subsystems which are under the responsibility of each institute. The Fore Optics derotates and anamorphoses the image at the focal plane. A Splitting and Relay Optics feed the 24 identical Integral Field Units (IFU), that are mounted within a large monolithic instrument mechanical structure. Each IFU incorporates an image slicer, a fully refractive spectrograph with VPH-grating and a detector system connected to a global vacuum and cryogenic system. During 2012 and 2013, all MUSE subsystems were integrated, aligned and tested to the P.I. institute at Lyon. After successful PAE in September 2013, MUSE instrument was shipped to the Very Large Telescope in Chile where it was aligned and tested in ESO integration hall at Paranal. After, MUSE was directly transferred in monolithic way onto VLT telescope where the first light was achieved. This paper describes the MUSE main optical component: the Field Splitter Unit. It splits the VLT image into 24 subfields and provides the first separation of the beam for the 24 Integral Field Units. This talk depicts its manufacturing at Winlight Optics and its alignment into MUSE instrument. The success of the MUSE alignment is demonstrated by the excellent results obtained onto MUSE positioning, image quality and throughput onto the sky. MUSE commissioning at the VLT is planned for September, 2014.

  17. Effect of Alignment on L2 Written Production

    ERIC Educational Resources Information Center

    Wang, Chuming; Wang, Min

    2015-01-01

    This article aims to uncover how L2 writing is affected by alignment, a socio-cognitive process involving dynamic coordination and adaptation. For this, two studies were conducted. Study 1 required two groups of 24 learners of English as a foreign language (EFL) to continue in English two stories with their endings removed, both of which had a…

  18. Systematic Image Based Optical Alignment and Tensegrity

    NASA Technical Reports Server (NTRS)

    Zeiders, Glenn W.; Montgomery, Edward E, IV (Technical Monitor)

    2001-01-01

    This presentation will review the objectives and current status of two Small Business Innovative Research being performed by the Sirius Group, under the direction of MSFC. They all relate to the development of advanced optical systems technologies for automated segmented mirror alignment techniques and fundamental design methodologies for ultralight structures. These are important to future astronomical missions in space.

  19. Review of Lean Construction Conference Proceedings and Relationship to the Toyota Production System Framework

    ERIC Educational Resources Information Center

    Jacobs, Gideon Francois

    2010-01-01

    The objective of this study was to align the International Group of Lean Construction (IGLC) conference proceedings against the Toyota Production System (TPS) to determine how well research themes in construction studies align with the TPS framework. Factories around the world that have implemented the TPS framework have experienced impressive…

  20. Enhancing the Alignment of the Preclinical and Clinical Stroke Recovery Research Pipeline: Consensus-Based Core Recommendations From the Stroke Recovery and Rehabilitation Roundtable Translational Working Group.

    PubMed

    Corbett, Dale; Carmichael, S Thomas; Murphy, Timothy H; Jones, Theresa A; Schwab, Martin E; Jolkkonen, Jukka; Clarkson, Andrew N; Dancause, Numa; Weiloch, Tadeusz; Johansen-Berg, Heidi; Nilsson, Michael; McCullough, Louise D; Joy, Mary T

    2017-08-01

    Stroke recovery research involves distinct biological and clinical targets compared to the study of acute stroke. Guidelines are proposed for the pre-clinical modeling of stroke recovery and for the alignment of pre-clinical studies to clinical trials in stroke recovery.

  1. Comparison of Accuracy between Side-Cutting Instruments and Front-Cutting Instruments in Minimally Invasive Total Knee Arthroplasty.

    PubMed

    Pinsornsak, Piya; Harnroongroj, Thos

    2016-11-01

    The specialized instrument system used in minimally invasive surgery (MIS) has been developed for reducing soft tissue trauma in total knee arthroplasty (TKA). Compared with front-cutting MIS instruments, side-cutting quadriceps sparing MIS instruments have the advantage of creating a smaller incision and causing fewer traumas to the quadriceps tendon. However, the accuracy of side-cutting instruments concerns surgeons in prosthesis malalignment. To compare the accuracy of side-cutting quadriceps sparing instruments versus front-cutting instruments in MIS-TKA. In this prospective randomized controlled study, we compared the accuracy of side-cutting quadriceps sparing instruments versus the front-cutting instruments used in MIS-TKA. Sixty knees were included in the study, with 30 knees in each group. All the operations were performed by single surgeon. Coronal alignment (tibiofemoral angle, lateral distal femoral angle, and medial proximal tibial angle), and sagittal alignment (femoral component flexion and tibial posterior slope) were measured and compared. Tibiofemoral angle, lateral distal femoral angle, and medial proximal tibial angle, all of which are considered in the assessment of acceptable coronal radiographic alignment, were not different between groups (p = 0.353, 0.500, and 0.177, respectively). However, side-cutting quadriceps sparing instruments produced less acceptable sagittal radiographic alignment, femoral component flexion (63% vs. 93%, p = 0.005), and tibial posterior slope (73% vs. 93%, p = 0.04). Side-cutting quadriceps sparing MIS-TKA instruments had similar accuracy to front-cutting MIS-TKA instruments for coronal alignment but is less accurate for sagittal alignment.

  2. Identifying and Aligning Expectations in a Mentoring Relationship

    PubMed Central

    Huskins, W. Charles; Silet, Karin; Weber‐Main, Anne Marie; Begg, Melissa D.; Fowler, Jr, Vance G.; Hamilton, John; Fleming, Michael

    2011-01-01

    Abstract The mentoring relationship between a scholar and their primary mentor is a core feature of research training. Anecdotal evidence suggests this relationship is adversely affected when scholar and mentor expectations are not aligned. We examined three questions: (1) What is the value in assuring that the expectations of scholars and mentors are mutually identified and aligned? (2) What types of programmatic interventions facilitate this process? (3) What types of expectations are important to identify and align? We addressed these questions through a systematic literature review, focus group interviews of mentors and scholars, a survey of Clinical and Translational Science Award (CTSA) KL2 program directors, and review of formal programmatic mechanisms used by KL2 programs. We found broad support for the importance of identifying and aligning the expectations of scholars and mentors and evidence that mentoring contracts, agreements, and training programs facilitate this process. These tools focus on aligning expectations with respect to the scholar’s research, education, professional development and career advancement as well as support, communication, and personal conduct and interpersonal relations. Research is needed to assess test the efficacy of formal alignment activities. Clin Trans Sci 2011; Volume 4: 439–447 PMID:22212226

  3. A quick and reliable procedure for assessing foot alignment in athletes.

    PubMed

    De Michelis Mendonça, Luciana; Bittencourt, Natália Franco Netto; Amaral, Giovanna Mendes; Diniz, Lívia Santos; Souza, Thales Rezende; da Fonseca, Sérgio Teixeira

    2013-01-01

    Quick procedures with proper psychometric properties that can capture the combined alignment of the foot-ankle complex in a position that may be more representative of the status of the lower limb during ground contact are essential for assessing a large group of athletes. The assessed lower limb was positioned with the calcaneus surface facing upward in a way that all of the marks could be seen at the center of the camera display. After guaranteeing maintenance of the foot at 90° of dorsiflexion actively sustained by the athlete, the examiner took the picture of the foot-ankle alignment. Intraclass correlation coefficients ranging from 0.82 to 0.93 demonstrated excellent intratester and intertester reliability for the proposed measurements of forefoot, rearfoot, and shank-forefoot alignments. The intraclass correlation coefficient between the shank-forefoot measures and the sum of the rearfoot and forefoot measures was 0.98, suggesting that the shank-forefoot alignment measures can represent the combined rearfoot and forefoot alignments. This study describes a reliable and practical measurement procedure for rearfoot, forefoot, and shank-forefoot alignments that can be applied to clinical and research situations as a screening procedure for risk factors for lower-limb injuries in athletes.

  4. Static knee alignment and its association with radiographic knee osteoarthritis.

    PubMed

    Teichtahl, A J; Cicuttini, F M; Janakiramanan, N; Davis, S R; Wluka, A E

    2006-09-01

    Although knee alignment is associated with the progression of knee osteoarthritis (OA), it is unclear which features that characterize radiographic OA are related to alignment. The aim of this study was to examine the relationship between static knee joint alignment (measured as a continuous variable) and the radiographic features of knee OA (joint space narrowing and osteophytes). One hundred and twenty one adults with symptomatic knee OA were recruited using a combined strategy including referral from specialist centres, arthritis support groups and media advertising. X-rays were performed to classify the severity of disease and to determine static knee alignment. Increasing varus knee alignment was associated with increasing risk of medial compartment joint space narrowing (P < 0.001) and osteophytes (P = 0.005). Increasing valgus knee alignment was associated with an increased risk for lateral compartment joint space narrowing (P < 0.001) and osteophytes (P = 0.002). This study has demonstrated that the static knee angle, measured as a continuous variable, is an important determinant of the compartment-specific features of radiographic knee OA. Further work is required to determine whether interventions aimed at correcting these relatively minor levels of varus and valgus angulation will have an effect on the risk of tibiofemoral OA.

  5. Global Alignment of Pairwise Protein Interaction Networks for Maximal Common Conserved Patterns

    DOE PAGES

    Tian, Wenhong; Samatova, Nagiza F.

    2013-01-01

    A number of tools for the alignment of protein-protein interaction (PPI) networks have laid the foundation for PPI network analysis. Most of alignment tools focus on finding conserved interaction regions across the PPI networks through either local or global mapping of similar sequences. Researchers are still trying to improve the speed, scalability, and accuracy of network alignment. In view of this, we introduce a connected-components based fast algorithm, HopeMap, for network alignment. Observing that the size of true orthologs across species is small comparing to the total number of proteins in all species, we take a different approach based onmore » a precompiled list of homologs identified by KO terms. Applying this approach to S. cerevisiae (yeast) and D. melanogaster (fly), E. coli K12 and S. typhimurium , E. coli K12 and C. crescenttus , we analyze all clusters identified in the alignment. The results are evaluated through up-to-date known gene annotations, gene ontology (GO), and KEGG ortholog groups (KO). Comparing to existing tools, our approach is fast with linear computational cost, highly accurate in terms of KO and GO terms specificity and sensitivity, and can be extended to multiple alignments easily.« less

  6. Some Dynamical Effects of the Cosmological Constant

    NASA Astrophysics Data System (ADS)

    Axenides, M.; Floratos, E. G.; Perivolaropoulos, L.

    Newton's law gets modified in the presence of a cosmological constant by a small repulsive term (antigravity) that is proportional to the distance. Assuming a value of the cosmological constant consistent with the recent SnIa data (Λ~=10-52 m-2), we investigate the significance of this term on various astrophysical scales. We find that on galactic scales or smaller (less than a few tens of kpc), the dynamical effects of the vacuum energy are negligible by several orders of magnitude. On scales of 1 Mpc or larger however we find that the vacuum energy can significantly affect the dynamics. For example we show that the velocity data in the local group of galaxies correspond to galactic masses increased by 35% in the presence of vacuum energy. The effect is even more important on larger low density systems like clusters of galaxies or superclusters.

  7. Roles of vacuum tunnelling and contact mechanics in single-molecule thermopower

    NASA Astrophysics Data System (ADS)

    Tsutsui, Makusu; Yokota, Kazumichi; Morikawa, Takanori; Taniguchi, Masateru

    2017-03-01

    Molecular junction is a chemically-defined nanostructure whose discrete electronic states are expected to render enhanced thermoelectric figure of merit suitable for energy-harvesting applications. Here, we report on geometrical dependence of thermoelectricity in metal-molecule-metal structures. We performed simultaneous measurements of the electrical conductance and thermovoltage of aromatic molecules having different anchoring groups at room temperature in vacuum. We elucidated the mutual contributions of vacuum tunnelling on thermoelectricity in the short molecular bridges. We also found stretching-induced thermoelectric voltage enhancement in thiol-linked single-molecule bridges along with absence of the pulling effects in diamine counterparts, thereby suggested that the electromechanical effect would be a rather universal phenomenon in Au-S anchored molecular junctions that undergo substantial metal-molecule contact elongation upon stretching. The present results provide a novel concept for molecular design to achieve high thermopower with single-molecule junctions.

  8. Co-pyrolysis behavior of fermentation residues with woody sawdust by thermogravimetric analysis and a vacuum reactor.

    PubMed

    Zheng, Yan; Zhang, Yimin; Xu, Jingna; Li, Xiayang; Charles Xu, Chunbao

    2017-12-01

    This study aimed at cost-effective utilization of fermentation residues (FR) from biogas project for bio-energy via co-pyrolysis of FR and woody sawdust (WS). In this study, a vacuum reactor was used to study the pyrolysis behaviors of individual and blend samples of FR and WS. Obvious synergistic effects were observed, resulting in a lower char yield but a higher gas yield. The presence of woody sawdust promoted the devolatilization of FR, and improved the syngas (H 2 and CO) content in the gaseous products. Compared to those of the char from pyrolysis of individual feedstock, co-pyrolysis of FR and WS in the vacuum reactor promoted the cracking reactions of large aromatic rings, enlarged the surface area and reduced the oxygenated groups of the resulted char. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Ceramic material suitable for repair of a space vehicle component in a microgravity and vacuum environment, method of making same, and method of repairing a space vehicle component

    NASA Technical Reports Server (NTRS)

    Riedell, James A. (Inventor); Easler, Timothy E. (Inventor)

    2009-01-01

    A precursor of a ceramic adhesive suitable for use in a vacuum, thermal, and microgravity environment. The precursor of the ceramic adhesive includes a silicon-based, preceramic polymer and at least one ceramic powder selected from the group consisting of aluminum oxide, aluminum nitride, boron carbide, boron oxide, boron nitride, hafnium boride, hafnium carbide, hafnium oxide, lithium aluminate, molybdenum silicide, niobium carbide, niobium nitride, silicon boride, silicon carbide, silicon oxide, silicon nitride, tin oxide, tantalum boride, tantalum carbide, tantalum oxide, tantalum nitride, titanium boride, titanium carbide, titanium oxide, titanium nitride, yttrium oxide, zirconium diboride, zirconium carbide, zirconium oxide, and zirconium silicate. Methods of forming the ceramic adhesive and of repairing a substrate in a vacuum and microgravity environment are also disclosed, as is a substrate repaired with the ceramic adhesive.

  10. Identity fusion predicts endorsement of pro-group behaviours targeting nationality, religion, or football in Brazilian samples.

    PubMed

    Bortolini, Tiago; Newson, Martha; Natividade, Jean Carlos; Vázquez, Alexandra; Gómez, Ángel

    2018-04-01

    A visceral feeling of oneness with a group - identity fusion - has proven to be a stronger predictor of pro-group behaviours than other measures of group bonding, such as group identification. However, the relationship between identity fusion, other group alignment measures and their different roles in predicting pro-group behaviour is still controversial. Here, we test whether identity fusion is related to, but different from, unidimensional and multidimensional measures of group identification. We also show that identity fusion explains further variance of the endorsement of pro-group behaviour than these alternative measures and examine the structural and discriminant properties of identity fusion and group identification measures in three different contexts: nationality, religion, and football fandom. Finally, we extend the fusion literature to a new culture: Brazil. To the best of our knowledge, this is the first research explicitly addressing a comparison between these two forms of group alignment, identity fusion and identification with a group, and their role in predicting pro-group behaviours. © 2018 The British Psychological Society.

  11. Advanced Accelerators for Medical Applications

    NASA Astrophysics Data System (ADS)

    Uesaka, Mitsuru; Koyama, Kazuyoshi

    We review advanced accelerators for medical applications with respect to the following key technologies: (i) higher RF electron linear accelerator (hereafter “linac”); (ii) optimization of alignment for the proton linac, cyclotron and synchrotron; (iii) superconducting magnet; (iv) laser technology. Advanced accelerators for medical applications are categorized into two groups. The first group consists of compact medical linacs with high RF, cyclotrons and synchrotrons downsized by optimization of alignment and superconducting magnets. The second group comprises laser-based acceleration systems aimed of medical applications in the future. Laser plasma electron/ion accelerating systems for cancer therapy and laser dielectric accelerating systems for radiation biology are mentioned. Since the second group has important potential for a compact system, the current status of the established energy and intensity and of the required stability are given.

  12. Advanced Accelerators for Medical Applications

    NASA Astrophysics Data System (ADS)

    Uesaka, Mitsuru; Koyama, Kazuyoshi

    We review advanced accelerators for medical applications with respect to the following key technologies: (i) higher RF electron linear accelerator (hereafter "linac"); (ii) optimization of alignment for the proton linac, cyclotron and synchrotron; (iii) superconducting magnet; (iv) laser technology. Advanced accelerators for medical applications are categorized into two groups. The first group consists of compact medical linacs with high RF, cyclotrons and synchrotrons downsized by optimization of alignment and superconducting magnets. The second group comprises laserbased acceleration systems aimed of medical applications in the future. Laser plasma electron/ion accelerating systems for cancer therapy and laser dielectric accelerating systems for radiation biology are mentioned. Since the second group has important potential for a compact system, the current status of the established energy and intensity and of the required stability are given.

  13. Interspecific variation in mitochondrial serine transfer RNA (UCN) in Euptychiina butterflies (Lepidoptera: Satyrinae): structure and alignment.

    PubMed

    Marín, Mario Alejandro; López, Andrés; Uribe, Sandra Inés

    2012-06-01

    The nucleotide variation and structural patterns of mitochondrial RNA molecule have been proposed as useful tools in molecular systematics; however, their usefulness is always subject to a proper assessment of homology in the sequence alignment. The present study describes the secondary structure of mitochondrial tRNA for the amino acid serine (UCN) on 13 Euptychiina species and the evaluation of its potential use for evolutionary studies in this group of butterflies. The secondary structure of tRNAs showed variation among the included species except between Hermeuptychia sp1 and sp2. Variation was concentrated in the ribotimidina-pseudouridine-cystosine (TψC), dihydrouridine (DHU) and variable loops and in the DHU and TψC arms. These results suggest this region as a potential marker useful for taxonomic differentiation of species in this group and also confirm the importance of including information from the secondary structure of tRNA to optimize the alignments.

  14. The place of the Local Group in the cosmic web

    NASA Astrophysics Data System (ADS)

    Forero-Romero, Jaime E.; González, Roberto

    2016-10-01

    We use the Bolshoi Simulation to find the most probable location of the Local Group (LG) in the cosmic web. Our LG simulacra are pairs of halos with isolation and kinematic properties consistent with observations. The cosmic web is defined using a tidal tensor approach. We find that the LG's preferred location is regions with a dark matter overdensity close to the cosmic average. This makes filaments and sheets the preferred environment. We also find a strong alignment between the LG and the cosmic web. The orbital angular momentum is preferentially perpendicular to the smallest tidal eigenvector, while the vector connecting the two halos is strongly aligned along the the smallest tidal eigenvector and perpendicular to the largest tidal eigenvector; the pair lies and moves along filaments and sheets. We do not find any evidence for an alignment between the spin of each halo in the pair and the cosmic web.

  15. Trace Gas Analyzer (TGA) program

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

  16. Skilled Nursing Facility Partnerships May Decrease 90-Day Costs in a Total Joint Arthroplasty Episode Under the Bundled Payments for Care Improvement Initiative.

    PubMed

    Behery, Omar A; Kouk, Shalen; Chen, Kevin K; Mullaly, Kathleen A; Bosco, Joseph A; Slover, James D; Iorio, Richard; Schwarzkopf, Ran

    2018-03-01

    The Bundled Payments for Care Improvement initiative was developed to reduce costs associated with total joint arthroplasty through a single payment for all patient care from index admission through a 90-day post-discharge period, including care at skilled nursing facilities (SNFs). The aim of this study is to investigate whether forming partnerships between hospitals and SNFs could lower the post-discharge costs. We hypothesize that institutionally aligned SNFs have lower post-discharge costs than non-aligned SNFs. A cohort of 615 elective, primary total hip and knee arthroplasty subjects discharged to an SNF under the Bundled Payments for Care Improvement from 2014 to 2016 were included in our analysis. Patients were grouped into one of the 3 categories of SNF alignment: group 1: non-partners; group 2: agreement-based partners; group 3: institution-owned partners. Demographics, comorbidities, length of stay (LOS) at SNF, and associated costs during the 90-day post-operative period were compared between the 3 groups. Mean index hospital LOS was statistically shortest in group 3 (mean 2.7 days vs 3.5 for groups 1 and 2, P = .001). SNF LOS was also shortest in group 3 (mean 11 days vs 19 and 21 days in groups 2 and 1 respectively, P < .001). Total SNF costs and total 90-day costs were both significantly lower in group 3 compared with groups 1 and 2 (P < .001 for all), even after controlling for medical comorbidities. Institution-owned partner SNFs demonstrated the shortest patient LOS, and the lowest SNF and total 90-day costs, without increased risk of readmissions, compared with other SNFs. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Starobinsky-Like Inflation and Running Vacuum in the Context of Supergravity

    NASA Astrophysics Data System (ADS)

    Basilakos, Spyros; Mavromatos, Nick; Solà, Joan

    2016-07-01

    We describe the primeval inflationary phase of the early Universe within a quantum field theoretical (QFT) framework that can be viewed as the effective action of vacuum decay in the early times. Interestingly enough, the model accounts for the "graceful exit" of the inflationary phase into the standard radiation regime. The underlying QFT framework considered here is Supergravity (SUGRA), more specifically an existing formulation in which the Starobinsky-type inflation (de-Sitter background) emerges from the quantum corrections to the effective action after integrating out the gravitino fields in their (dynamically induced) massive phase. We also demonstrate that the structure of the effective action in this model is consistent with the generic idea of renormalization group (RG) running of the cosmological parameters, specifically it follows from the corresponding RG equation for the vacuum energy density as a function of the Hubble rate, $\\rho_{\\Lambda}(H)$. Overall our combined approach amounts to a concrete-model realization of inflation triggered by vacuum decay in a fundamental physics context which, as it turns out, can also be extended for the remaining epochs of the cosmological evolution until the current dark energy era.

  18. The retail display life of steaks prepared from chill stored vacuum and carbon dioxide-packed sub-primal beef cuts.

    PubMed

    Bell, R G; Penney, N; Moorhead, S M

    1996-01-01

    Chilled striploins and cube rolls from ten Australian steers (grain-fed for 150 days) were trimmed of external fat and cut transversely into portions approximately 10 cm thick, each weighing between 750 and 1000 g. These 'retailer-ready' cuts were each wrapped in drip saver pads and slid inside a plastic sleeve before being individually placed into a clear plastic high oxygen barrier film, metallized film or conventional vacuum bag. Cuts in clear plastic and metallized film packs were packaged in an oxygen-free saturated carbon dioxide atmosphere (CO(2)-CAP), those in vacuum bags were conventionally vacuum-packed. All packs were returned to the chiller for further cooling. After 24 hr, half the clear plastic and metallized CO(2)-CAP packs were carbon dioxide master-packed in groups of eight. Retailer-ready cuts in both clear plastic and metallized film single unit and master-packed CO(2)-CAP packs were air freighted to New Zealand and sea freighted to Japan for assessment. The control vacuum packs were all consigned to New Zealand. Assessments in both countries after 39-89 days storage at between 0 °C and -1.0 °C indicated that fat colour stability limited the retail display life of steaks cut from meat in these retailer-ready packs to approximately 48 hr. In this regard, meat from single unit CO(2)-CAP, master pack CO(2)-CAP and vacuum packs performed similarly. Lean meat colour and sensory attributes remained acceptable for up to 48 hr after displayed product was rejected because of grey-green fat discoloration. The microbiological status of retailer-ready cuts removed from CO(2)-CAP packs after 89 days chilled storage was superior to that of cuts from vacuum packs. Clear plastic and metallized film CO(2)-CAP packs performed comparably.

  19. Secure alignment of coordinate systems using quantum correlation

    NASA Astrophysics Data System (ADS)

    Rezazadeh, F.; Mani, A.; Karimipour, V.

    2017-08-01

    We show that two parties far apart can use shared entangled states and classical communication to align their coordinate systems with a very high fidelity. Moreover, compared with previous methods proposed for such a task, i.e., sending parallel or antiparallel pairs or groups of spin states, our method has the extra advantages of using single-qubit measurements and also being secure, so that third parties do not extract any information about the aligned coordinate system established between the two parties. The latter property is important in many other quantum information protocols in which measurements inevitably play a significant role.

  20. The Relationship Between Early-Stage Knee Osteoarthritis and Lower-Extremity Alignment, Joint Laxity, and Subjective Scores of Pain, Stiffness, and Function.

    PubMed

    Hicks-Little, Charlie A; Peindl, Richard D; Hubbard-Turner, Tricia J; Cordova, Mitchell L

    2016-08-01

    Knee osteoarthritis (OA) is a debilitating disease that affects an estimated 27 million Americans. Changes in lower-extremity alignment and joint laxity have been found to redistribute the medial and/or lateral loads at the joint. However, the effect that changes in anteroposterior knee-joint laxity have on lower-extremity alignment and function in individuals with knee OA remains unclear. To examine anteroposterior knee-joint laxity, lower-extremity alignment, and subjective pain, stiffness, and function scores in individuals with early-stage knee OA and matched controls and to determine if a relationship exists among these measures. Case control. Sports-medicine research laboratory. 18 participants with knee OA and 18 healthy matched controls. Participants completed the Western Ontario McMaster (WOMAC) osteoarthritis questionnaire and were tested for total anteroposterior knee-joint laxity (A-P) and knee-joint alignment (ALIGN). WOMAC scores, A-P (mm), and ALIGN (°). A significant multivariate main effect for group (Wilks' Λ = 0.30, F7,26 = 8.58, P < .0001) was found. Knee-OA participants differed in WOMAC scores (P < .0001) but did not differ from healthy controls on ALIGN (P = .49) or total A-P (P = .66). No significant relationships were identified among main outcome measures. These data demonstrate that participants with early-stage knee OA had worse pain, stiffness, and functional outcome scores than the matched controls; however, ALIGN and A-P were no different. There was no association identified among participants' subjective scores, ALIGN, or A-P measures in this study.

  1. Prospective cohort study of a new vacuum delivery device to assist with complicated labour in low-resource settings.

    PubMed

    Khan, Mishal; Hashmani, Farah Naz; Ahmed, Sajjad; Ahmed, Owais; Asim, Shabnam S; Wajahat, Yasmin; Sobani, Shoaib; Syed, Shershah; Qazi, Fahad

    2015-02-01

    Currently available vacuum devices used to assist women undergoing complicated labour are unsuitable for use in low-resource settings. The objective of this study was to evaluate the safety and feasibility of a new low-cost vacuum device, named Koohi Goth Vacuum Delivery System (KGVDS), designed for use in low-resource settings. A hospital-based, multicentre, prospective cohort study with no control group was conducted in Karachi, Pakistan. After training, KGVDS devices were made available for use by labour room staff at their discretion when instrumental delivery was indicated. Women to whom KGVDS was applied were followed from the start of labour until discharge. Feasibility was assessed in terms of successful expulsion of the foetal head following application of KGVDS and ease of use ratings. Safety was assessed by observing maternal and newborn post-delivery outcomes prior to discharge. Koohi Goth Vacuum Delivery System was applied to 137 women requiring instrumental delivery, of whom 111 (81%; 95% CI = 74-88%) successfully expelled the foetal head assisted by KGVDS and 103 (75%) stated that they would agree to use KGVDS again. There were no serious maternal or neonatal injuries or infections related to KGVDS use. The mean score for 'ease of use' given by doctors and midwives using the device was 8 of 10. Koohi Goth Vacuum Delivery System was feasible and safe to use for assisting complicated deliveries in low-resource hospitals in this initial evaluation. Our results indicate that this new device may have the potential to improve birth outcomes in settings where most mortality occurs and that further evaluations should be conducted. © 2014 John Wiley & Sons Ltd.

  2. Aligning Game Activity with Educational Goals: Following a Constrained Design Approach to Instructional Computer Games

    ERIC Educational Resources Information Center

    Shelton, Brett E.; Scoresby, Jon

    2011-01-01

    We discuss the design, creation and implementation of an instructional game for use in a high school poetry class following a commitment to an educational game design principle of "alignment". We studied groups of instructional designers and an interactive fiction computer game they built. The game was implemented in a 9th grade English classroom…

  3. Emergence of a coherent and cohesive swarm based on mutual anticipation

    PubMed Central

    Murakami, Hisashi; Niizato, Takayuki; Gunji, Yukio-Pegio

    2017-01-01

    Collective behavior emerging out of self-organization is one of the most striking properties of an animal group. Typically, it is hypothesized that each individual in an animal group tends to align its direction of motion with those of its neighbors. Most previous models for collective behavior assume an explicit alignment rule, by which an agent matches its velocity with that of neighbors in a certain neighborhood, to reproduce a collective order pattern by simple interactions. Recent empirical studies, however, suggest that there is no evidence for explicit matching of velocity, and that collective polarization arises from interactions other than those that follow the explicit alignment rule. We here propose a new lattice-based computational model that does not incorporate the explicit alignment rule but is based instead on mutual anticipation and asynchronous updating. Moreover, we show that this model can realize densely collective motion with high polarity. Furthermore, we focus on the behavior of a pair of individuals, and find that the turning response is drastically changed depending on the distance between two individuals rather than the relative heading, and is consistent with the empirical observations. Therefore, the present results suggest that our approach provides an alternative model for collective behavior. PMID:28406173

  4. Correlation between knee and hindfoot alignment in patients with rheumatoid arthritis: The effects of subtalar joint destruction.

    PubMed

    Nakada, Izumi; Nakamura, Ichiro; Juji, Takuo; Ito, Katsumi; Matsumoto, Takumi

    2015-09-01

    Compensatory hindfoot alignment for deformities at the knee level has been demonstrated in patients with knee osteoarthritis. However, this phenomenon has not been elucidated in patients with rheumatoid arthritis (RA). The aim of this study is to investigate the relationship between knee deformity and hindfoot alignment and the effect of subtalar joint destruction in patients with RA. We retrospectively investigated RA patients (110 patients, 205 limbs) using radiographs in the standing anteroposterior knee, standing lateral foot, and hindfoot alignment views. The grade of destruction at the knee and subtalar joints was assigned using Larsen's grading system. The correlation between the femorotibial and tibiocalcaneal angles and the effect of joint destruction on this correlation were analyzed using Pearson's correlation coefficients. There was moderate correlation between the femorotibial and tibiocalcaneal angles in a group of knees with a Larsen grade of ≥ 4 (r = 0.544, p = 0.0239). This correlation was stronger in a group with less damaged subtalar joints with a Larsen grade of ≤ 3 (r = 0.705, p = 0.0049). These findings emphasized the importance of examining foot and ankles in patients with RA who undergo total knee arthroplasty.

  5. The influence of Si in Ni on the interface modification and the band alignment between Ni and alumina

    NASA Astrophysics Data System (ADS)

    Yoshitake, Michiko; Nemšák, Slavomír; Skála, Tomáš; Tsud, Nataliya; Matolín, Vladimír; Prince, Kevin C.

    2018-06-01

    The influence of a small amount of Si in a Ni single crystal on the interface formation between aluminum oxide and Ni has been investigated. The interface was formed by in-situ growth of the oxide by simultaneous supply of Al and oxygen onto Ni(1 1 1) in an ultrahigh vacuum chamber equipped with XPS apparatus. The oxide growth and the interface formation were compared between Si-containing Ni(1 1 1) and pure Ni(1 1 1). It was revealed that Si segregated on the surface of Ni and oxidized, forming an epitaxial thin alumino-silicate film. Valence band spectra demonstrated that the band offset between the oxide and Ni (energy level difference between the valence band top and the Fermi level) is different due to the oxidized Si segregation at the interface.

  6. Method and apparatus for charged particle propagation

    DOEpatents

    Hershcovitch, A.

    1996-11-26

    A method and apparatus are provided for propagating charged particles from a vacuum to a higher pressure region. A generator includes an evacuated chamber having a gun for discharging a beam of charged particles such as an electron beam or ion beam. The beam is discharged through a beam exit in the chamber into a higher pressure region. A plasma interface is disposed at the beam exit and includes a plasma channel for bounding a plasma maintainable between a cathode and an anode disposed at opposite ends thereof. The plasma channel is coaxially aligned with the beam exit for propagating the beam from the chamber, through the plasma, and into the higher pressure region. The plasma is effective for pumping down the beam exit for preventing pressure increase in the chamber and provides magnetic focusing of the beam discharged into the higher pressure region 24. 7 figs.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wenger, D. F.; Sinars, D. B.; Rochau, G. A.

    An early prototype of a focusing spectrometer with one-dimensional (1D) spatial resolution (FSSR) instrument was previously developed for use in the vacuum chamber of the Sandia Z facility [Sinars et al., J. Quant. Spectrosc. Radiat. Transf. 99, 595 (2006)]. This instrument used a single, spherically bent crystal to measure time-integrated Ar spectra from 0.295-0.378 nm with {lambda}/{delta}{lambda}>2000 and a 1D axial spatial resolution of {approx}50 {mu}m. We present the design of a final version of this instrument that improves the shielding, can be aligned more accurately, and uses three crystals instead of one. The last change enables coverage of multiplemore » spectral ranges if different crystals are used, or multiple times if identical crystals and time-gated detectors are used. We also present results from initial prototyping tests on the Z facility using two crystals in a time-integrated mode.« less

  8. Experimental studies of high-confinement mode plasma response to non-axisymmetric magnetic perturbations in ASDEX Upgrade

    DOE PAGES

    Suttrop, Wolfgang; Kirk, A.; Nazikian, R.; ...

    2016-11-22

    Here, the interaction of externally applied small non-axisymmetric magnetic perturbations (MP) with tokamak high-confinement mode (H-mode) plasmas is reviewed and illustrated by recent experiments in ASDEX Upgrade. The plasma response to the vacuum MP field is amplified by stable ideal kink modes with low toroidal mode number n driven by the H-mode edge pressure gradient (and associated bootstrap current) which is experimentally evidenced by an observable shift of the poloidal mode number m away from field alignment (m = qn, with q being the safety factor) at the response maximum. A torque scan experiment demonstrates the importance of the perpendicular electron flow for shielding of the resonant magnetic perturbation, as expected from a two-fluid MHD picture. Two significant effects of MP occur in H-mode plasmas at low pedestal collisionality,more » $$\

  9. Design and Preliminary Testing of a High Performance Antiproton Trap (HiPAT)

    NASA Technical Reports Server (NTRS)

    Martin, James; Meyer, Kirby; Kramer, Kevin; Smith, Gerald; Lewis, Raymond; Rodgers, Stephen L. (Technical Monitor)

    2000-01-01

    Antimatter represents the pinnacle of energy density, offering the potential to enhance current fusion/fission concepts enabling various classes of deep space missions. Current production rates are sufficient to support proof-of-concept evaluation of many key technologies associated with antimatter-derived propulsion. Storage has been identified as a key enabling technology for all antimatter-related operations, and as such is the current focus of this NASA-MSFC effort to design and fabricate a portable device capable of holding up to 10(exp 12) particles. Hardware has been assembled and initial tests are underway to evaluate the trap behavior using electron gun generated, positive hydrogen ions. Ions have been stored for tens of minutes, limited by observed interaction with background gas. Additionally, radio frequency manipulation is being tested to increase lifetime by stabilizing the stored particles, potentially reducing their interaction with background gas, easing requirements on ultimate trap vacuum and precision mechanical alignment.

  10. NSLS-II storage ring insertion device and front-end commissioning and operation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, G., E-mail: gwang@bnl.gov; Shaftan, T.; Amundsen, C.

    The National Synchrotron Light Source II (NSLS-II) is a state of the art 3 GeV third generation light source at Brookhaven National Laboratory. During spring/ summer of 2014, the storage ring was commissioned up to 50 mA without insertion devices. In the fall of 2014, we began commissioning of the project beamlines, which included seven insertion devices on six ID ports. Beamlines IXS, HXN, CSX-1, CSX-2, CHX, SRX, and XPD-1 consist of elliptically polarized undulator (EPU), damping wigglers (DW) and in-vacuum undulators (IVU) covering from VUV to hard x-ray range. In this paper, experience with commissioning and operation is discussed.more » We focus on reaching storage ring performance with IDs, including injection, design emittance, compensation of orbit distortions caused by ID residual field, source point stability, beam alignment and tools for control, monitoring and protection of the ring chambers from ID radiation.« less

  11. Trehalose glycopolymer resists allow direct writing of protein patterns by electron-beam lithography

    NASA Astrophysics Data System (ADS)

    Bat, Erhan; Lee, Juneyoung; Lau, Uland Y.; Maynard, Heather D.

    2015-03-01

    Direct-write patterning of multiple proteins on surfaces is of tremendous interest for a myriad of applications. Precise arrangement of different proteins at increasingly smaller dimensions is a fundamental challenge to apply the materials in tissue engineering, diagnostics, proteomics and biosensors. Herein, we present a new resist that protects proteins during electron-beam exposure and its application in direct-write patterning of multiple proteins. Polymers with pendant trehalose units are shown to effectively crosslink to surfaces as negative resists, while at the same time providing stabilization to proteins during the vacuum and electron-beam irradiation steps. In this manner, arbitrary patterns of several different classes of proteins such as enzymes, growth factors and immunoglobulins are realized. Utilizing the high-precision alignment capability of electron-beam lithography, surfaces with complex patterns of multiple proteins are successfully generated at the micrometre and nanometre scale without requiring cleanroom conditions.

  12. Design and prototype studies of the TOTEM Roman pot detectors

    NASA Astrophysics Data System (ADS)

    Oriunno, Marco; Battistin, Michele; David, Eric; Guglielmini, Paolo; Joram, Christian; Radermacher, Ernst; Ruggiero, Gennaro; Wu, Jihao; Vacek, Vaclav; Vins, Vaclav

    2007-10-01

    The Roman pots of the TOTEM experiment at LHC will be equipped with edgeless silicon micro-strip detectors. A detector package consists of 10 detector planes cooled at -15C in vacuum. The detector resolution is 20 μm, the overall alignment precision has to be better than 30 μm. The detector planes are composed of a kapton hybrid glued on a substrate made of low expansion alloy, CE07 with 70% Si and 30% Al. An evaporative cooling system based on the fluorocarbon C3F8 with oil-free compressors has been adopted. The throttling of the fluid is done locally through capillaries. A thermo-mechanical prototype has been assembled. The results fully match the requirements and the expectations of calculations. They show a low thermal gradient on the cards and a uniform temperature distribution over the 10 planes.

  13. Plasma-sprayed, self-lubricating coatings for use from cryogenic temperatures to 870 deg C (1600 deg F)

    NASA Technical Reports Server (NTRS)

    Sliney, H. E.

    1975-01-01

    A plasma-sprayed coating is described with good lubricating properties over a wide temperature range. The coating, designated NASA LUBE PS101, contains silver, nichrome, calcium fluoride, and an oxidation protective glass. Oscillating tests were conducted of self-aligning, plain cylindrical bearings, in which the bore was lined with 0.025 cm (0.010 in.) thick coatings of PS101; these were conducted at a radial load of 3.5 x 10 to the 7th power N/sq m (5000 psi) in nitrogen gas at -107 C (-160 F), in vacuum at room temperature, and in air from room temperature to 870 C (1600 F). Friction coefficients were less than 0.25 in all cases and wear rates were low. The coating is not brittle, and it has adequate oxidation resistance in air to at least 870 C.

  14. Thermal design and test results for SUNLITE ultra-stable reference cavity

    NASA Technical Reports Server (NTRS)

    Amundsen, Ruth M.

    1991-01-01

    SUNLITE (Stanford University-NASA Laser In-Space Technology Experiment) is a space-based experiment which uses a reference cavity to provide a stable frequency reference for a terahertz laser oscillator. Thermal stability of the cavity is a key factor in attaining a stable narrow-linewidth laser beam. The mount which is used to support and align the cavity will provide thermal isolation from the environment. The baseline requirement for thermal stability of the cavity is 0.025 C/min, but the design is directed toward achieving stability well beyond this requirement to improve the science data gained. A prototype of the cavity mount was fabricated and tested to characterize the thermal performance. The thermal vacuum test involved stable high-resolution temperature measurements and stable baseplate temperature control over long durations. Based on test data, the cavity mount design satisfies the severe requirement for the cavity thermal stability.

  15. The Muon g-2 Experiment overview and status as of June 2016

    DOE PAGES

    Holzbauer, J. L.

    2016-12-09

    The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will also extend the search for the electric dipole moment (EDM) of the muon by approximately two orders of magnitude, with a sensitivity down to 10 -21 e.cm. Both of these measurements are made by combining a precise measurement of the 1.45T storage ring magnetic field with an analysis of the modulation of the decay rate of higher-energy positrons (from anti-muons),more » recorded by 24 calorimeters and 3 straw tracking detectors. Furthermore, the recent progress in the alignment of the electrostatic quadrapole plates and the trolley rails inside the vacuum chambers, and in establishing the uniform storage ring magnetic field will be described.« less

  16. ATF neutral beam injection: optimization of beam alignment and aperturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, R.N.; Fowler, R.H.; Rome, J.A.

    1985-12-01

    The application of the existing Impurity Study Experiment (ISX-B) neutral beam injectors for the Advanced Toroidal Facility (ATF) is studied. It is determined that with the practical considerations of beam aperturing, ATF vacuum vessel complexity, and realistic beam modeling, the power absorbed by the plasma will be approximately 57% of the extracted neutral beam power, which corresponds to an injected power of about 1.5 MW. By reducing the beam divergence to a 1/sup 0/ Gaussian distribution, the absorbed power could be increased to 93%. The power delivered to the plasma is found to be a strong function of the beammore » divergence but only a weak function of the beam focal length. Shinethrough can be a serious problem if very low density startups are necessary. Preliminary calculations indicate that there will be no excessive fast-ion losses. 12 refs., 17 figs., 1 tab.« less

  17. Fused silica GRISMs manufactured by hydrophilic direct bonding at moderate heating

    NASA Astrophysics Data System (ADS)

    Kalkowski, G.; Grabowski, K.; Harnisch, G.; Flügel-Paul, T.; Zeitner, U.; Risse, S.

    2017-12-01

    For high-resolution spectroscopy in space, GRISM elements—obtained by patterning gratings onto a prism surface—find increasing applications. We report on GRISM manufacturing by joining the individual functional elements—prisms and gratings—to suitable components by the technology of hydrophilic direct bonding. Fused silica was used as a substrate material and binary gratings were fabricated by standard e-beam lithography and dry etching. Alignment of the grating dispersion direction to the prism angle was realized by passive adjustment on dedicated bonding gear matched to the substrate geometry. Materials adapted bonds of high transmission, stiffness, and strength were obtained after heat treatment at temperatures of about 200 °C in vacuum. Examples for bonding uncoated as well as coated grating surfaces are given. The results illustrate the great potential of hydrophilic glass direct bonding for manufacturing transmission optics to be used in space or other heavy duty applications.

  18. Observations of cavity polaritons in one-dimensional photonic crystals containing a liquid-crystalline semiconductor based on perylene bisimide units

    NASA Astrophysics Data System (ADS)

    Sakata, T.; Suzuki, M.; Yamamoto, T.; Nakanishi, S.; Funahashi, M.; Tsurumachi, N.

    2017-10-01

    We investigated the optical transmission properties of one-dimensional photonic crystal (1D-PC) microcavity structures containing the liquid-crystalline (LC) perylene tetracarboxylic bisimide (PTCBI) derivative. We fabricated the microcavity structures for this study by two different methods and observed the cavity polaritons successfully in both samples. For one sample, since the PTCBI molecules were aligned in the cavity layer of the 1D-PC by utilizing a friction transfer method, vacuum Rabi splitting energy was strongly dependent on the polarization of the incident light produced by the peculiar optical features of the LC organic semiconductor. For the other sample, we did not utilize the friction transfer method and did not observe such polarization dependence. However, we did observe a relatively large Rabi splitting energy of 187 meV, probably due to the improvement of optical confinement effect.

  19. Elmo bumpy square plasma confinement device

    DOEpatents

    Owen, L.W.

    1985-01-01

    The invention is an Elmo bumpy type plasma confinement device having a polygonal configuration of closed magnet field lines for improved plasma confinement. In the preferred embodiment, the device is of a square configuration which is referred to as an Elmo bumpy square (EBS). The EBS is formed by four linear magnetic mirror sections each comprising a plurality of axisymmetric assemblies connected in series and linked by 90/sup 0/ sections of a high magnetic field toroidal solenoid type field generating coils. These coils provide corner confinement with a minimum of radial dispersion of the confined plasma to minimize the detrimental effects of the toroidal curvature of the magnetic field. Each corner is formed by a plurality of circular or elliptical coils aligned about the corner radius to provide maximum continuity in the closing of the magnetic field lines about the square configuration confining the plasma within a vacuum vessel located within the various coils forming the square configuration confinement geometry.

  20. Six degree-of-freedom scanning supports and manipulators based on parallel robots

    NASA Astrophysics Data System (ADS)

    Comin, Fabio

    1995-02-01

    The exploitation of third generation SR sources heavily relies on accurate and stable positioning and scanning of samples and optical elements. In some cases, active feedback is also necessary. Normally, these tasks are carried out by serial addition of individual components, each of them providing a well-defined excursion path. On the contrary, the exploitation of the concept of parallel robots, structures in close cinematic chain, permits us to follow any given trajectory in the six-dimensional space with a large increase in accuracy and stiffness. At ESRF, the parallel robot architecture conceived some tens of years ago for flight simulators has been adapted to both actively align and operate optical elements of considerable weight and position small samples in ultrahigh vacuum. The performance of these devices gives results far superior to the initial specification and a variety of drive mechanisms are being developed to fit the different needs of the ESRF beamlines.

  1. The Muon g-2 Experiment Overview and Status as of June 2016

    NASA Astrophysics Data System (ADS)

    Holzbauer, J.

    2016-11-01

    The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will also extend the search for the electric dipole moment (EDM) of the muon by approximately two orders of magnitude, with a sensitivity down to 10-21 e.cm. Both of these measurements are made by combining a precise measurement of the 1.45T storage ring magnetic field with an analysis of the modulation of the decay rate of higher-energy positrons (from anti-muons), recorded by 24 calorimeters and 3 straw tracking detectors. The recent progress in the alignment of the electrostatic quadrapole plates and the trolley rails inside the vacuum chambers, and in establishing the uniform storage ring magnetic field will be described.

  2. [Application research of presacral space drainage tube combined with subcutaneous vacuum pressure suction in the laparoscopic-assisted abdominoperineal resection].

    PubMed

    Chen, Liqi; Zeng, Changqing; Chi, Liangjie; Huang, Liangxiang; Li, Jiandang

    2017-08-25

    To study the management for the perineal incision after laparoscopic-assisted abdominoperineal resection for rectal cancer. Clinical data of 87 patients undergoing laparoscopic Miles operation for lower rectal cancer from June 2009 to February 2014 were collected and studied. Presacral space drainage group: presacral space drainage tube was applied in 42 patients. Combined drainage group: presacral space drainage tube combined with subcutaneous vacuum pressure suction was applied in 45 cases. In combined drainage group, except the presacral drainage tube, another drainage tube was placed subcutaneously and connected to a negative pressure ball, which was fixed on the lateral anterior of perineal wound by the further incision and drainage. After subcutaneous tube was placed for 2 weeks, as drainage fluid was limpid and <15 ml/d for 3 days, meanwhile no obvious pelvic fluid was detected by ultrasound, and the wound healed quite well without redness and edema, then the subcutaneous tube with the negative pressure ball could be removed. There were 51 males and 36 females with the mean age of 26-78(56.9±10.8) years old. The laparoscopic Miles operation was successfully completed in all the cases without death and complications. The drainage tube was placed for 4-13(8.0±2.5) days in presacral space drainage group, and for 4-14(6.7±2.4) days in combined drainage group. The subcutaneous tube was placed for 14-24(15.8±3.0) days. The primary healing rate of perineal wound in presacral space drainage group and combined drainage group was 66.7%(28/42) and 91.1%(41/45) respectively, while the perineal wound infection rate was 21.4%(9/42) and 4.4%(2/45) respectively, whose differences between two groups were both significant (χ 2 =7.911, P=0.005 and χ 2 =5.674, P=0.017). Presacral space drainage tube combined with subcutaneous vacuum pressure suction in laparoscopic-assisted abdominoperineal resection for rectal cancer has better efficacy and lower infection rate for perineal incision, which is worth wide application.

  3. Preflight calibration of the Imaging Magnetograph eXperiment polarization modulation package based on liquid-crystal variable retarders.

    PubMed

    Uribe-Patarroyo, Néstor; Alvarez-Herrero, Alberto; Martínez Pillet, Valentín

    2012-07-20

    We present the study, characterization, and calibration of the polarization modulation package (PMP) of the Imaging Magnetograph eXperiment (IMaX) instrument, a successful Stokes spectropolarimeter on board the SUNRISE balloon project within the NASA Long Duration Balloon program. IMaX was designed to measure the Stokes parameters of incoming light with a signal-to-noise ratio of at least 103, using as polarization modulators two nematic liquid-crystal variable retarders (LCVRs). An ad hoc calibration system that reproduced the optical and environmental characteristics of IMaX was designed, assembled, and aligned. The system recreates the optical beam that IMaX receives from SUNRISE with known polarization across the image plane, as well as an optical system with the same characteristics of IMaX. The system was used to calibrate the IMaX PMP in vacuum and at different temperatures, with a thermal control resembling the in-flight one. The efficiencies obtained were very high, near theoretical maximum values: the total efficiency in vacuum calibration at nominal temperature was 0.972 (1 being the theoretical maximum). The condition number of the demodulation matrix of the same calibration was 0.522 (0.577 theoretical maximum). Some inhomogeneities of the LCVRs were clear during the pixel-by-pixel calibration of the PMP, but it can be concluded that the mere information of a pixel-per-pixel calibration is sufficient to maintain high efficiencies in spite of inhomogeneities of the LCVRs.

  4. An in-vacuo optical levitation trap for high-intensity laser interaction experiments with isolated microtargets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, C. J., E-mail: c.price10@imperial.ac.uk; Giltrap, S.; Stuart, N. H.

    2015-03-15

    We report on the design, construction, and characterisation of a new class of in-vacuo optical levitation trap optimised for use in high-intensity, high-energy laser interaction experiments. The system uses a focused, vertically propagating continuous wave laser beam to capture and manipulate micro-targets by photon momentum transfer at much longer working distances than commonly used by optical tweezer systems. A high speed (10 kHz) optical imaging and signal acquisition system was implemented for tracking the levitated droplets position and dynamic behaviour under atmospheric and vacuum conditions, with ±5 μm spatial resolution. Optical trapping of 10 ± 4 μm oil droplets inmore » vacuum was demonstrated, over timescales of >1 h at extended distances of ∼40 mm from the final focusing optic. The stability of the levitated droplet was such that it would stay in alignment with a ∼7 μm irradiating beam focal spot for up to 5 min without the need for re-adjustment. The performance of the trap was assessed in a series of high-intensity (10{sup 17} W cm{sup −2}) laser experiments that measured the X-ray source size and inferred free-electron temperature of a single isolated droplet target, along with a measurement of the emitted radio-frequency pulse. These initial tests demonstrated the use of optically levitated microdroplets as a robust target platform for further high-intensity laser interaction and point source studies.« less

  5. Highly reproducible laser beam scanning device for an internal source laser desorption microprobe Fourier transform mass spectrometer

    NASA Astrophysics Data System (ADS)

    Scott, Jill R.; Tremblay, Paul L.

    2002-03-01

    Traditionally, mass spectrometry has relied on manipulating the sample target to provide scanning capabilities for laser desorption microprobes. This has been problematic for an internal source laser desorption Fourier transform mass spectrometer (LD-FTMS) because of the high magnetic field (7 Tesla) and geometric constraints of the superconducting magnet bore. To overcome these limitations, we have implemented a unique external laser scanning mechanism for an internal source LD-FTMS. This mechanism provides adjustable resolution enhancement so that the spatial resolution at the target is not limited to that of the stepper motors at the light source (˜5 μm/step). The spatial resolution is now limited by the practical optical diffraction limit of the final focusing lens. The scanning mechanism employs a virtual source that is wavelength independent up to the final focusing lens, which can be controlled remotely to account for focal length dependence on wavelength. A binary index provides an automatic alignment feature. The virtual source is located ˜9 ft from the sample; therefore, it is completely outside of the vacuum system and beyond the 50 G line of the fringing magnetic field. To eliminate reproducibility problems associated with vacuum pump vibrations, we have taken advantage of the magnetic field inherent to the FTMS to utilize Lenz's law for vibrational dampening. The LD-FTMS microprobe has exceptional reproducibility, which enables successive mapping sequences for depth-profiling studies.

  6. An in-vacuo optical levitation trap for high-intensity laser interaction experiments with isolated microtargets

    NASA Astrophysics Data System (ADS)

    Price, C. J.; Donnelly, T. D.; Giltrap, S.; Stuart, N. H.; Parker, S.; Patankar, S.; Lowe, H. F.; Drew, D.; Gumbrell, E. T.; Smith, R. A.

    2015-03-01

    We report on the design, construction, and characterisation of a new class of in-vacuo optical levitation trap optimised for use in high-intensity, high-energy laser interaction experiments. The system uses a focused, vertically propagating continuous wave laser beam to capture and manipulate micro-targets by photon momentum transfer at much longer working distances than commonly used by optical tweezer systems. A high speed (10 kHz) optical imaging and signal acquisition system was implemented for tracking the levitated droplets position and dynamic behaviour under atmospheric and vacuum conditions, with ±5 μm spatial resolution. Optical trapping of 10 ± 4 μm oil droplets in vacuum was demonstrated, over timescales of >1 h at extended distances of ˜40 mm from the final focusing optic. The stability of the levitated droplet was such that it would stay in alignment with a ˜7 μm irradiating beam focal spot for up to 5 min without the need for re-adjustment. The performance of the trap was assessed in a series of high-intensity (1017 W cm-2) laser experiments that measured the X-ray source size and inferred free-electron temperature of a single isolated droplet target, along with a measurement of the emitted radio-frequency pulse. These initial tests demonstrated the use of optically levitated microdroplets as a robust target platform for further high-intensity laser interaction and point source studies.

  7. Revisiting the phylogeny of Zoanthidea (Cnidaria: Anthozoa): Staggered alignment of hypervariable sequences improves species tree inference.

    PubMed

    Swain, Timothy D

    2018-01-01

    The recent rapid proliferation of novel taxon identification in the Zoanthidea has been accompanied by a parallel propagation of gene trees as a tool of species discovery, but not a corresponding increase in our understanding of phylogeny. This disparity is caused by the trade-off between the capabilities of automated DNA sequence alignment and data content of genes applied to phylogenetic inference in this group. Conserved genes or segments are easily aligned across the order, but produce poorly resolved trees; hypervariable genes or segments contain the evolutionary signal necessary for resolution and robust support, but sequence alignment is daunting. Staggered alignments are a form of phylogeny-informed sequence alignment composed of a mosaic of local and universal regions that allow phylogenetic inference to be applied to all nucleotides from both hypervariable and conserved gene segments. Comparisons between species tree phylogenies inferred from all data (staggered alignment) and hypervariable-excluded data (standard alignment) demonstrate improved confidence and greater topological agreement with other sources of data for the complete-data tree. This novel phylogeny is the most comprehensive to date (in terms of taxa and data) and can serve as an expandable tool for evolutionary hypothesis testing in the Zoanthidea. Spanish language abstract available in Text S1. Translation by L. O. Swain, DePaul University, Chicago, Illinois, 60604, USA. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Relationships between static foot alignment and dynamic plantar loads in runners with acute and chronic stages of plantar fasciitis: a cross-sectional study

    PubMed Central

    Ribeiro, Ana P.; Sacco, Isabel C. N.; Dinato, Roberto C.; João, Silvia M. A.

    2016-01-01

    BACKGROUND: The risk factors for the development of plantar fasciitis (PF) have been associated with the medial longitudinal arch (MLA), rearfoot alignment and calcaneal overload. However, the relationships between the biomechanical variables have yet to be determined. OBJECTIVE: The goal of this study was to investigate the relationships between the MLA, rearfoot alignment, and dynamic plantar loads in runners with unilateral PF in acute and chronic phases. METHOD: Cross-sectional study which thirty-five runners with unilateral PF were evaluated: 20 in the acute phase (with pain) and 15 with previous chronic PF (without pain). The MLA index and rearfoot alignment were calculated using digital images. The contact area, maximum force, peak pressure, and force-time integral over three plantar areas were acquired with Pedar X insoles while running at 12 km/h, and the loading rates were calculated from the vertical forces. RESULTS: The multiple regression analyses indicated that both the force-time integral (R 2=0.15 for acute phase PF; R 2=0.17 for chronic PF) and maximum force (R 2=0.35 for chronic PF) over the forefoot were predicted by an elevated MLA index. The rearfoot valgus alignment predicted the maximum force over the rearfoot in both PF groups: acute (R 2=0.18) and chronic (R 2=0.45). The rearfoot valgus alignment also predicted higher loading rates in the PF groups: acute (R 2=0.19) and chronic (R 2=0.40). CONCLUSION: The MLA index and the rearfoot alignment were good predictors of plantar loads over the forefoot and rearfoot areas in runners with PF. However, rearfoot valgus was demonstrated to be an important clinical measure, since it was able to predict the maximum force and both loading rates over the rearfoot. PMID:26786073

  9. HIV Sequence Compendium 2010

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuiken, Carla; Foley, Brian; Leitner, Thomas

    This compendium is an annual printed summary of the data contained in the HIV sequence database. In these compendia we try to present a judicious selection of the data in such a way that it is of maximum utility to HIV researchers. Each of the alignments attempts to display the genetic variability within the different species, groups and subtypes of the virus. This compendium contains sequences published before January 1, 2010. Hence, though it is called the 2010 Compendium, its contents correspond to the 2009 curated alignments on our website. The number of sequences in the HIV database is stillmore » increasing exponentially. In total, at the time of printing, there were 339,306 sequences in the HIV Sequence Database, an increase of 45% since last year. The number of near complete genomes (>7000 nucleotides) increased to 2576 by end of 2009, reflecting a smaller increase than in previous years. However, as in previous years, the compendium alignments contain only a small fraction of these. Included in the alignments are a small number of sequences representing each of the subtypes and the more prevalent circulating recombinant forms (CRFs) such as 01 and 02, as well as a few outgroup sequences (group O and N and SIV-CPZ). Of the rarer CRFs we included one representative each. A more complete version of all alignments is available on our website, http://www.hiv.lanl.gov/content/sequence/NEWALIGN/align.html. Reprints are available from our website in the form of both HTML and PDF files. As always, we are open to complaints and suggestions for improvement. Inquiries and comments regarding the compendium should be addressed to seq-info@lanl.gov.« less

  10. Alignment and component position after patient-matched instrumentation versus conventional total knee arthroplasty.

    PubMed

    Pourgiezis, N; Reddy, S P; Nankivell, M; Morrison, G; VanEssen, J

    2016-08-01

    To compare patient-matched instrumentation (PMI) with conventional total knee arthroplasty (TKA) in terms of limb alignment and component position. Nine men and 36 women (mean age, 69.5 years) who underwent PMI TKA were compared with 20 men and 25 women (mean age, 69.3 years) who underwent conventional TKA by the same team of surgeons with the same prosthesis and protocols in terms of limb alignment and component position using the Perth protocol computed tomography, as well as bone resection measurements, operating time, and the number of trays used. The PMI and conventional TKA groups were comparable in terms of age, body mass index, tourniquet time, operating time, and the number of trays used. For limb alignment and component position, the 2 groups differed significantly in sagittal femoral component position (2.4º vs. 0.9º, p=0.0008) and the percentage of knees with femoral component internally rotated ≥1° with respect to the transepicondylar axis (20% vs. 55%, p=0.001). The difference was not significant in terms of limb alignment, coronal and rotational femoral component position, or coronal and sagittal tibial component position. Intra-operatively, all patient-matched cutting blocks demonstrated acceptable fit and stability. No instrument-related adverse events or complications were encountered. One (2.2%) femur and 6 (13.3%) tibiae were recut 2 mm for optimal ligament balancing. Two femoral components were upsized to the next size, and 2 tibial components were upsized and 2 downsized to the next size. PMI was as accurate as conventional instrumentation in TKA. There was no significant difference in limb alignment or femoral and tibial component position in the coronal and sagittal planes between PMI and conventional TKA. PMI had a higher tendency to achieve correct femoral component rotation.

  11. Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial.

    PubMed

    Victor, Jan; Dujardin, Jan; Vandenneucker, Hilde; Arnout, Nele; Bellemans, Johan

    2014-01-01

    Recently, patient-specific guides (PSGs) have been introduced, claiming a significant improvement in accuracy and reproducibility of component positioning in TKA. Despite intensive marketing by the manufacturers, this claim has not yet been confirmed in a controlled prospective trial. We (1) compared three-planar component alignment and overall coronal mechanical alignment between PSG and conventional instrumentation and (2) logged the need for applying changes in the suggested position of the PSG. In this randomized controlled trial, we enrolled 128 patients. In the PSG cohort, surgical navigation was used as an intraoperative control. When the suggested cut deviated more than 3° from target, the use of PSG was abandoned and marked as an outlier. When cranial-caudal position or size was adapted, the PSG was marked as modified. All patients underwent long-leg standing radiography and CT scan. Deviation of more than 3° from the target in any plane was defined as an outlier. The PSG and conventional cohorts showed similar numbers of outliers in overall coronal alignment (25% versus 28%; p = 0.69), femoral coronal alignment (7% versus 14%) (p = 0.24), and femoral axial alignment (23% versus 17%; p = 0.50). There were more outliers in tibial coronal (15% versus 3%; p = 0.03) and sagittal 21% versus 3%; p = 0.002) alignment in the PSG group than in the conventional group. PSGs were abandoned in 14 patients (22%) and modified in 18 (28%). PSGs do not improve accuracy in TKA and, in our experience, were somewhat impractical in that the procedure needed to be either modified or abandoned with some frequency.

  12. Mechanisms of the Anterior Cruciate Ligament Injury in Sports Activities: A Twenty-Year Clinical Research of 1,700 Athletes

    PubMed Central

    Kobayashi, Hirokazu; Kanamura, Tomonao; Koshida, Sentaro; Miyashita, Koji; Okado, Tsuruo; Shimizu, Takuya; Yokoe, Kiyoshi

    2010-01-01

    The mechanisms of anterior cruciate ligament (ACL) injuries are still inconclusive from an epidemiological standpoint. An epidemiological approach in a large sample group over an appropriate period of years will be necessary to enhance the current knowledge of the ACL injury mechanism. The objective of the study was to investigate the ACL injury occurrence in a large sample over twenty years and demonstrate the relationships between the ACL injury occurrence and the dynamic knee alignment at the time of the injury. We investigated the activity, the injury mechanism, and the dynamic knee alignment at the time of the injury in 1,718 patients diagnosed as having the ACL injuries. Regarding the activity at the time of the injury, “competition ”was the most common, accounting for about half of all the injuries. The current result also showed that the noncontact injury was the most common, which was observed especially in many female athletes. Finally, the dynamic alignment of “Knee-in & Toe- out ”(i.e. dynamic knee valgus) was the most common, accounting for about half. These results enhance our understanding of the ACL injury mechanism and may be used to guide future injury prevention strategies. Key points We investigated the situation of ACL injury occurrence, especially dynamic alignments at the time of injury, in 1,718 patients who had visited our institution for surgery and physical therapy for twenty years. Our epidemiological study of the large patient group revealed that “knee-in & toe-out ”alignment was the most frequently seen at the time of the ACL injury. From an epidemiological standpoint, we need to pay much attention to avoiding “Knee-in & Toe-out ”alignment during sports activities. PMID:24149795

  13. Computer assisted alignment of opening wedge high tibial osteotomy provides limited improvement of radiographic outcomes compared to flouroscopic alignment.

    PubMed

    Stanley, Jeremy C; Robinson, Kerian G; Devitt, Brian M; Richmond, Anneka K; Webster, Kate E; Whitehead, Timothy S; Feller, Julian A

    2016-03-01

    There are numerous methods available to assist surgeons in the accurate correction of varus alignment during medial opening wedge high tibial osteotomy (MOWHTO). Preoperative planning performed with radiographs or more recently intraoperative computer navigation software has been used. The aim of the study was to compare the accuracy of computer navigated versus non-navigated techniques to correct varus alignment of the knee. The preoperative and postoperative radiographs of 117 knees that underwent MOWHTO were investigated to assess radiographic limb alignment 12-months postoperatively. The desired correction was defined as a weight bearing line (Mikulicz point {MP}) 58% of the width of the tibial plateau from the medial tibial margin. Sixty-five knees were corrected using a conventional technique and 52 knees were corrected using computer navigation. The mean MP percentage was 59% in the navigated group, compared with 56% in the fluoroscopic group (p=0.183). 51.9% of the navigation knees were corrected to within five percent of the desired correction, in contrast to 38.5% of the fluoroscopically corrected knees (p=0.15). 71.2% of the navigated knees were corrected to within 10% of the desired correction, compared with 63.1% of the fluoroscopically corrected knees (p=0.36). Large preoperative deformities were more accurately corrected with navigation assistance (57% vs 49%, p=0.049). No statistically significant difference was found in the radiographic correction of varus alignment twelve months postoperatively between navigated and fluoroscopic techniques of MOWHTO. However, a subgroup analysis demonstrated that larger preoperative varus deformities may be more accurately corrected using computer navigation. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Color Confinement and Screening in the θ Vacuum of QCD

    DOE PAGES

    Kharzeev, Dmitri E.; Levin, Eugene M.

    2015-06-16

    QCD perturbation theory ignores the compact nature of the SU(3) gauge group that gives rise to the periodic θ vacuum of the theory. In this paper, we propose to modify the gluon propagator to reconcile perturbation theory with the anomalous Ward identities for the topological current in the θ vacuum. As a result, the gluon couples to the Veneziano ghost describing the tunneling transitions between different Chern-Simons sectors of the vacuum; we call the emerging gluon dressed by ghost loops a “glost.” We evaluate the glost propagator and find that it has the form G(p)=(p 2+χ top/p 2) -1 wheremore » χ top is the Yang-Mills topological susceptibility related to the η" mass by the Witten-Veneziano relation; this propagator describes the confinement of gluons at distances ~χ top -1/4≃1 fm. The same functional form of the propagator was originally proposed by Gribov as a solution to the gauge copies problem that plagues perturbation theory. The resulting running coupling coincides with the perturbative one at p 2>>√χtop, but in the infrared region either freezes (in pure Yang-Mills theory) or vanishes (in full QCD with light quarks), in accord with experimental evidence. In conclusion, our scenario makes explicit the connection between confinement and topology of the QCD vacuum; we discuss the implications for spin physics, high energy scattering, and the physics of quark-gluon plasma.« less

  15. Analysis of four dental alloys following torch/centrifugal and induction/ vacuum-pressure casting procedures.

    PubMed

    Thompson, Geoffrey A; Luo, Qing; Hefti, Arthur

    2013-12-01

    Previous studies have shown casting methodology to influence the as-cast properties of dental casting alloys. It is important to consider clinically important mechanical properties so that the influence of casting can be clarified. The purpose of this study was to evaluate how torch/centrifugal and inductively cast and vacuum-pressure casting machines may affect the castability, microhardness, chemical composition, and microstructure of 2 high noble, 1 noble, and 1 base metal dental casting alloys. Two commonly used methods for casting were selected for comparison: torch/centrifugal casting and inductively heated/ vacuum-pressure casting. One hundred and twenty castability patterns were fabricated and divided into 8 groups. Four groups were torch/centrifugally cast in Olympia (O), Jelenko O (JO), Genesis II (G), and Liberty (L) alloys. Similarly, 4 groups were cast in O, JO, G, and L by an inductively induction/vacuum-pressure casting machine. Each specimen was evaluated for casting completeness to determine a castability value, while porosity was determined by standard x-ray techniques. Each group was metallographically prepared for further evaluation that included chemical composition, Vickers microhardness, and grain analysis of microstructure. Two-way ANOVA was used to determine significant differences among the main effects. Statistically significant effects were examined further with the Tukey HSD procedure for multiple comparisons. Data obtained from the castability experiments were non-normal and the variances were unequal. They were analyzed statistically with the Kruskal-Wallis rank sum test. Significant results were further investigated statistically with the Steel-Dwass method for multiple comparisons (α=.05). The alloy type had a significant effect on surface microhardness (P<.001). In contrast, the technique used for casting did not affect the microhardness of the test specimen (P=.465). Similarly, the interaction between the alloy and casting technique was not significant (P=.119). A high level of castability (98.5% on average) was achieved overall. The frequency of casting failures as a function of alloy type and casting method was determined. Failure was defined as a castability index score of <100%. Three of 28 possible comparisons between alloy and casting combinations were statistically significant. The results suggested that casting technique affects the castability index of alloys. Radiographic analysis detected large porosities in regions near the edge of the castability pattern and infrequently adjacent to noncast segments. All castings acquired traces of elements found in the casting crucibles. The grain size for each dental casting alloy was generally finer for specimens produced by the induction/vacuum-pressure method. The difference was substantial for JO and L. This study demonstrated a relation between casting techniques and some physical properties of metal ceramic casting alloys. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  16. Report to DHS on Summer Internship 2006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beckwith, R H

    2006-07-26

    This summer I worked at Lawrence Livermore National Laboratory in a bioforensics collection and extraction research group under David Camp. The group is involved with researching efficiencies of various methods for collecting bioforensic evidence from crime scenes. The different methods under examination are a wipe, swab, HVAC filter and a vacuum. The vacuum is something that has particularly gone uncharacterized. My time was spent mostly on modeling and calculations work, but at the end of the summer I completed my internship with a few experiments to supplement my calculations. I had two major projects this summer. My first major projectmore » this summer involved fluid mechanics modeling of collection and extraction situations. This work examines different fluid dynamic models for the case of a micron spore attached to a fiber. The second project I was involved with was a statistical analysis of the different sampling techniques.« less

  17. Development of Accurate Structure for Mounting and Aligning Thin-Foil X-Ray Mirrors

    NASA Technical Reports Server (NTRS)

    Heilmann, Ralf K.

    2001-01-01

    The goal of this work was to improve the assembly accuracy for foil x-ray optics as produced by the high-energy astrophysics group at the NASA Goddard Space Flight Center. Two main design choices lead to an alignment concept that was shown to improve accuracy well within the requirements currently pursued by the Constellation-X Spectroscopy X-Ray Telescope (SXT).

  18. INDUCED EEG GAMMA OSCILLATION ALIGNMENT IMPROVES DIFFERENTIATION BETWEEN AUTISM AND ADHD GROUP RESPONSES IN A FACIAL CATEGORIZATION TASK

    PubMed Central

    Gross, Eric; El-Baz, Ayman S.; Sokhadze, Guela E.; Sears, Lonnie; Casanova, Manuel F.; Sokhadze, Estate M.

    2012-01-01

    Introduction Children diagnosed with an autism spectrum disorder (ASD) often lack the ability to recognize and properly respond to emotional stimuli. Emotional deficits also characterize children with attention deficit/hyperactivity disorder (ADHD), in addition to exhibiting limited attention span. These abnormalities may effect a difference in the induced EEG gamma wave burst (35–45 Hz) peaked approximately 300–400 milliseconds following an emotional stimulus. Because induced gamma oscillations are not fixed at a definite point in time post-stimulus, analysis of averaged EEG data with traditional methods may result in an attenuated gamma burst power. Methods We used a data alignment technique to improve the averaged data, making it a better representation of the individual induced EEG gamma oscillations. A study was designed to test the response of a subject to emotional stimuli, presented in the form of emotional facial expression images. In a four part experiment, the subjects were instructed to identify gender in the first two blocks of the test, followed by differentiating between basic emotions in the final two blocks (i.e. anger vs. disgust). EEG data was collected from ASD (n=10), ADHD (n=9), and control (n=11) subjects via a 128 channel EGI system, and processed through a continuous wavelet transform and bandpass filter to isolate the gamma frequencies. A custom MATLAB code was used to align the data from individual trials between 200–600 ms post-stimulus, EEG site, and condition by maximizing the Pearson product-moment correlation coefficient between trials. The gamma power for the 400 ms window of maximum induced gamma burst was then calculated and compared between subject groups. Results and Conclusion Condition (anger/disgust recognition, gender recognition) × Alignment × Group (ADHD, ASD, Controls) interaction was significant at most of parietal topographies (e.g., P3–P4, P7–P8). These interactions were better manifested in the aligned data set. Our results show that alignment of the induced gamma oscillations improves sensitivity of this measure in differentiation of EEG responses to emotional facial stimuli in ADHD and ASD. PMID:22754277

  19. INDUCED EEG GAMMA OSCILLATION ALIGNMENT IMPROVES DIFFERENTIATION BETWEEN AUTISM AND ADHD GROUP RESPONSES IN A FACIAL CATEGORIZATION TASK.

    PubMed

    Gross, Eric; El-Baz, Ayman S; Sokhadze, Guela E; Sears, Lonnie; Casanova, Manuel F; Sokhadze, Estate M

    2012-01-01

    INTRODUCTION: Children diagnosed with an autism spectrum disorder (ASD) often lack the ability to recognize and properly respond to emotional stimuli. Emotional deficits also characterize children with attention deficit/hyperactivity disorder (ADHD), in addition to exhibiting limited attention span. These abnormalities may effect a difference in the induced EEG gamma wave burst (35-45 Hz) peaked approximately 300-400 milliseconds following an emotional stimulus. Because induced gamma oscillations are not fixed at a definite point in time post-stimulus, analysis of averaged EEG data with traditional methods may result in an attenuated gamma burst power. METHODS: We used a data alignment technique to improve the averaged data, making it a better representation of the individual induced EEG gamma oscillations. A study was designed to test the response of a subject to emotional stimuli, presented in the form of emotional facial expression images. In a four part experiment, the subjects were instructed to identify gender in the first two blocks of the test, followed by differentiating between basic emotions in the final two blocks (i.e. anger vs. disgust). EEG data was collected from ASD (n=10), ADHD (n=9), and control (n=11) subjects via a 128 channel EGI system, and processed through a continuous wavelet transform and bandpass filter to isolate the gamma frequencies. A custom MATLAB code was used to align the data from individual trials between 200-600 ms post-stimulus, EEG site, and condition by maximizing the Pearson product-moment correlation coefficient between trials. The gamma power for the 400 ms window of maximum induced gamma burst was then calculated and compared between subject groups. RESULTS AND CONCLUSION: Condition (anger/disgust recognition, gender recognition) × Alignment × Group (ADHD, ASD, Controls) interaction was significant at most of parietal topographies (e.g., P3-P4, P7-P8). These interactions were better manifested in the aligned data set. Our results show that alignment of the induced gamma oscillations improves sensitivity of this measure in differentiation of EEG responses to emotional facial stimuli in ADHD and ASD.

  20. Descemet Stripping Automated Endothelial Keratoplasty for Failed Penetrating Keratoplasty: Influence of the Graft-Host Junction on the Graft Survival Rate.

    PubMed

    Omoto, Takashi; Sakisaka, Toshihiro; Toyono, Tetsuya; Yoshida, Junko; Shirakawa, Rika; Miyai, Takashi; Yamagami, Satoru; Usui, Tomohiko

    2018-04-01

    To investigate the clinical results of Descemet stripping automated endothelial keratoplasty (DSAEK) for failed penetrating keratoplasty (PK) and the influence of the graft-host junction (GHJ) on the graft survival rate. Data were retrospectively collected on patient demographics, visual outcomes, complications, and graft survival rate for 17 eyes of 16 patients who underwent DSAEK for failed PK. The graft survival rate was compared between the eyes when divided into a bump group and a well-aligned group according to the shape of the GHJ detected on anterior segment optical coherence tomography. The most common indication for initial PK was bullous keratopathy after glaucoma surgery (35.3%). Seven eyes (41.2%) were classified into the bump group and 10 eyes (58.8%) into the well-aligned group. The mean best-ever documented visual acuity (BDVA) after DSAEK was 0.33 logMAR. Postoperatively, almost 70% of eyes achieved a BDVA that was within 0.2 logMAR of their preoperative BDVA. Graft detachment occurred in 29.4% of eyes and primary graft failure in 17.6%. All primary failures occurred in the bump group. The cumulative graft survival rate was 82.3% at 1 year, 73.2% at 2 years, and 58.6% at 3 years. Graft failure was more likely in eyes in the bump group than in those in the well-aligned group (P = 0.037, Wilcoxon test). DSAEK for failed PK had a favorable outcome in this study. However, the GHJ should be assessed carefully before performing the procedure.

  1. Efficacy of a Pelvic Lateral Positioner With a Mechanical Cup Navigator Based on the Anatomical Pelvic Plane in Total Hip Arthroplasty.

    PubMed

    Iwakiri, Kentaro; Kobayashi, Akio; Ohta, Yoichi; Minoda, Yukihide; Takaoka, Kunio; Nakamura, Hiroaki

    2017-12-01

    The acetabular component orientation in total hip arthroplasty (THA) is of critical importance to the good clinical results. However, traditional widely used cup alignment guides for cup placement are reported to be relatively unreliable. The present study aims at comparing a novel cup alignment guide, which can be attached to our anatomical pelvic plane (APP) pelvic lateral positioner for reducing discrepancies in sagittal pelvic tilt and indicate a targeted cup angle based on the APP, with a conventional cup alignment guide. The subjects were 136 hips of 136 patients who underwent unilateral THA using the APP positioner. The procedure was performed with the conventional cup alignment guide (conventional group; 60 hips) and with the novel cup navigator (mechanical navigator group; 76 hips). Postoperative cup angles and discrepancies of postoperative cup angles (inclination and anteversion angles) from the targeted angles were compared between the 2 groups to evaluate the usefulness of these navigators. The mean cup angles in the conventional group were 39.0° ± 5.3° for the inclination angle and 21.7° ± 6.4° for the anteversion angle, whereas those in the mechanical navigator group were 40.6° ± 3.2° and 18.3° ± 4.6°, respectively (P = .018, P < .0001). The discrepancies from the targeted angles were 3.5° ± 3.1° for the inclination angle and 4.6° ± 3.4° for the anteversion angle in the conventional group and 2.3° ± 2.3° and 3.2° ± 2.7°, respectively, in the mechanical navigator group (P = .020, P = .012). The mechanical cup navigator easily attachable to the APP positioner is a tool that can improve the accuracy of cup placement in a simple, economical, and noninvasive manner in THA via the lateral position. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Cell Alignment Required in Differentiation of Myxococcus xanthus

    NASA Astrophysics Data System (ADS)

    Kim, Seung K.; Kaiser, Dale

    1990-08-01

    During fruiting body morphogenesis of Myxococcus xanthus, cell movement is required for transmission of C-factor, a short range intercellular signaling protein necessary for sporulation and developmental gene expression. Nonmotile cells fail to sporulate and to express C-factor-dependent genes, but both defects were rescued by a simple manipulation of cell position that oriented the cells in aligned, parallel groups. A similar pattern of aligned cells normally results from coordinated recruitment of wild-type cells into multicellular aggregates, which later form mature fruiting bodies. It is proposed that directed cell movement establishes critical contacts between adjacent cells, which are required for efficient intercellular C-factor transmission.

  3. Energy Level Alignment at the Interface between Linear-Structured Benzenediamine Molecules and Au(111) Surface

    NASA Astrophysics Data System (ADS)

    Li, Guo; Rangel, Tonatiuh; Liu, Zhenfei; Cooper, Valentino; Neaton, Jeffrey

    Using density functional theory with model self-energy corrections, we calculate the adsorption energetics and geometry, and the energy level alignment of benzenediamine (BDA) molecules adsorbed on Au(111) surfaces. Our calculations show that linear structures of BDA, stabilized via hydrogen bonds between amine groups, are energetically more favorable than monomeric phases. Moreover, our self-energy-corrected calculations of energy level alignment show that the highest occupied molecular orbital energy of the BDA linear structure is deeper relative to the Fermi level relative to the isolated monomer and agrees well with the values measured with photoemission spectroscopy. This work supported by DOE.

  4. [Effect of Codonopsis Radix maintained with sulfur fumigation on immune function in mice].

    PubMed

    Liu, Cheng-song; Wang, Yu-ping; Shi, Yan-bin; Ma, Xing-ming; Li, Hui-li; Zhang, Xiao-yun; Li, Shou-tang

    2014-11-01

    To investigate the immune function of mice being given the extract of Codonopsis Radix maintained with sulfur fumigation. Mice were divided into five groups. Except the normal control group, the mice were fed with the extract of Codonopsis Radix maintained with sulfur fumigation at the high,medium and low doses, as well as medium dose of Codonopsis Radix maintained with low-temperature vacuum method, respectively. Mice were treated once a day for 10 continuous days. Weight change,organ indexes, blood cell indices, macrophage phagocytic function, and IL-2 and IFN-γ levels were measured. Compared with normal control group, Codonopsis Radix maintained with sulfur fumigation at medium and high doses inhibited body weight increase of mice; white blood cell count of high dose group was significantly increased; significant increase of macrophage phagocytosis were observed for all groups except the normal control group; and spleen index and IFN-γ level of Codonopsis Radix maintained with sulfur fumigation medium dose group were increased significantly. Codonopsis Radix maintained with sulfur fumigation can promote mouse immune function to a certain degree. There was no difference in immune effect between Codonopsis Radix maintained with sulfur fumigation and low-temperature vacuum method during experimental period. However,taking the extract of Codonopsis Radix maintained with sulfur fumigation can exert negative effect on appetite and body weight in mice.

  5. Indian Vacuum Society: The Indian Vacuum Society

    NASA Astrophysics Data System (ADS)

    Saha, T. K.

    2008-03-01

    The Indian Vacuum Society (IVS) was established in 1970. It has over 800 members including many from Industry and R & D Institutions spread throughout India. The society has an active chapter at Kolkata. The society was formed with the main aim to promote, encourage and develop the growth of Vacuum Science, Techniques and Applications in India. In order to achieve this aim it has conducted a number of short term courses at graduate and technician levels on vacuum science and technology on topics ranging from low vacuum to ultrahigh vacuum So far it has conducted 39 such courses at different parts of the country and imparted training to more than 1200 persons in the field. Some of these courses were in-plant training courses conducted on the premises of the establishment and designed to take care of the special needs of the establishment. IVS also regularly conducts national and international seminars and symposia on vacuum science and technology with special emphasis on some theme related to applications of vacuum. A large number of delegates from all over India take part in the deliberations of such seminars and symposia and present their work. IVS also arranges technical visits to different industries and research institutes. The society also helped in the UNESCO sponsored post-graduate level courses in vacuum science, technology and applications conducted by Mumbai University. The society has also designed a certificate and diploma course for graduate level students studying vacuum science and technology and has submitted a syllabus to the academic council of the University of Mumbai for their approval, we hope that some colleges affiliated to the university will start this course from the coming academic year. IVS extended its support in standardizing many of the vacuum instruments and played a vital role in helping to set up a Regional Testing Centre along with BARC. As part of the development of vacuum education, the society arranges the participation of expert members on the subject to deliver lectures and take part in devising courses in the universities. IVS publishes a quarterly called the `Bulletin of Indian Vacuum Society' since its inception, in which articles on vacuum and related topics are published. NIRVAT, news, announcements, and reports are the other features of the Bulletin. The articles in the Bulletin are internationally abstracted. The Bulletin is distributed free to all the members of the society. The society also publishes proceedings of national/international symposia and seminars, manuals, lecture notes etc. It has published a `Vacuum Directory' containing very useful information on vacuum technology. IVS has also set up its own website http://www.ivsnet.org in January 2002. The website contains information about IVS, list of members, list of EC members, events and news, abstracts of articles published in the `Bulletin of Indian Vacuum Society', utilities, announcements, reports, membership and other forms which can be completed online and also gives links to other vacuum societies. Our Society has been a member of the executive council of the International Union of Vacuum Science, Techniques and Applications (IUVSTA) and its various committees since 1970. In 1983 IVS conducted an International Symposium on Vacuum Technology and Nuclear Applications in BARC, Mumbai, under the sponsorship of IUVSTA. In 1987 IVS arranged the Triennial International Conference on Thin Films in New Delhi, where more than 200 foreign delegates participated. IVS also hosted the IUVSTA Executive Council Meeting along with the conference. The society organized yet again an International Conference on Vacuum Science and Technology and SRS Vacuum Systems at CAT, Indore in1995. IVS arranges the prestigious Professor Balakrishnan Memorial Lecture in memory of its founder vice-president. Leading scientists from India and abroad in the field are invited to deliver the talks. So far 23 lectures have been held in this series. IVS has instituted the `IVS- Professor D Y Phadke Memorial Prize' in memory of our founder president, the late Professor D Y Phadke at the University of Mumbai. The prize is given every year to the student ranked top in the MSc (PHY.) examination conducted by the university. The IVS Kolkata Chapter has established the Dr A S Divatia Memorial Trust with the objective of organizing the Dr A S Divatia Memorial Lecture and a seminar once a year and to set up a vacuum testing and calibration facility. IVS has instituted an award in memory of the late Shri C Ambasankaran, its past president and pioneer of vacuum technology in India. This award is given to one of the best papers presented in the national symposium conducted by IVS. One more best paper award `Smt. Shakuntalabai Vyawahare Memorial Prize' is established from a donation given by Shri Mohan R Vyawahare, a life member and a present EC member of the society, in memory of his mother. During the symposia, IVS felicitates two of its members, one from Industry and one from an R & D Institution for their lifetime contribution to vacuum science and technology. Dr A K Gupta, Ex BARC, Ex Generla Manager, IBP, Head, Energy Group, Shapoorji Pallonji & Co Ltd (Industry), and Dr S R Gowariker, Ex BARC, Ex Director, CSIO, Chandigarh, Director, Tolani Education Foundation (R & D) are being honoured this year. T K Saha Geneneral Secretary, IVS

  6. Impact of an auditory stimulus on baseline cortisol concentrations in clinically normal dogs.

    PubMed

    Gin, T E; Puchot, M L; Cook, A K

    2018-03-19

    Baseline cortisol concentrations are routinely used to screen dogs for hypoadrenocorticism (HOC); this diagnosis must then be confirmed with an ACTH stimulation test. A baseline cortisol concentration less than 55 nmol/L (2 μg/dL) is highly sensitive for HOC but lacks specificity, with a false positive rate >20%. Many dogs with nonadrenal disease are therefore subjected to unnecessary additional testing. It was hypothesized that exposure to an unpleasant auditory stimulus before sample collection would improve the specificity of baseline cortisol measurements in dogs with nonadrenal disease by triggering cortisol production. Twenty-eight healthy client-owned dogs were included in the study, with a median age of 4 yr (range 2-9 yr) and a median weight of 20 kg (range 10-27 kg). Dogs were ineligible for inclusion if they had received short- or long-acting glucocorticoids within the previous 30 and 90 d, respectively. Dogs were randomly assigned to group 1 (control; no noise; n = 7), group 2 (brief noise: n = 10), or group 3 (long noise: n = 11). Each dog and owner were directed to a secluded area for approximately 15 min. Group 1 sat in relative quiet, exposed only to the background sounds of a veterinary hospital. Group 2 were exposed to the sound of a wet-dry vacuum in an adjacent hallway during the first 3 min of this period. Group 3 were exposed to random bursts of wet-dry vacuum noise during this period. At the end of the test interval, each dog was escorted to an adjacent examination room for blood collection. Samples were processed within 15 min; serum was frozen at -80°C before measurement of cortisol concentrations. Median serum cortisol concentrations and the proportion of dogs with results <55 nmol/L were similar for the 3 groups. The study hypothesis that exposure to the noise of a wet-dry vacuum cleaner would consistently drive baseline serum cortisol concentrations above 55 nmol/L in dogs with apparently normal adrenal function was therefore rejected. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Smart and precise alignment of optical systems

    NASA Astrophysics Data System (ADS)

    Langehanenberg, Patrik; Heinisch, Josef; Stickler, Daniel

    2013-09-01

    For the assembly of any kind of optical systems the precise centration of every single element is of particular importance. Classically the precise alignment of optical components is based on the precise centering of all components to an external axis (usually a high-precision rotary spindle axis). Main drawback of this timeconsuming process is that it is significantly sensitive to misalignments of the reference (e.g. the housing) axis. In order to facilitate process in this contribution we present a novel alignment strategy for the TRIOPTICS OptiCentric® instrument family that directly aligns two elements with respect to each other by measuring the first element's axis and using this axis as alignment reference without the detour of considering an external reference. According to the optical design any axis in the system can be chosen as target axis. In case of the alignment to a barrel this axis is measured by using a distance sensor (e.g., the classically used dial indicator). Instead of fine alignment the obtained data is used for the calculation of its orientation within the setup. Alternatively, the axis of an optical element (single lens or group of lenses) whose orientation is measured with the standard OptiCentric MultiLens concept can be used as a reference. In the instrument's software the decentering of the adjusting element to the calculated axis is displayed in realtime and indicated by a target mark that can be used for the manual alignment. In addition, the obtained information can also be applied for active and fully automated alignment of lens assemblies with the help of motorized actuators.

  8. Evaluation of the role of Carnobacterium piscicola in spoilage of vacuum- and modified-atmosphere-packed cold-smoked salmon stored at 5 degrees C.

    PubMed

    Paludan-Müller, C; Dalgaard, P; Huss, H H; Gram, L

    1998-02-17

    The microflora on spoiled cold-smoked salmon often consists of a mixture of lactic acid bacteria (LAB) and Gram-negative bacteria. To elucidate the role of the different groups, a storage trial was carried out in which nisin and CO2 were used for the selective inhibition of the two bacterial groups. The shelf-life of vacuum-packed cold-smoked salmon, recorded by sensory evaluation, was four weeks at 5 degrees C and the microflora was composed of LAB (10(6)-10(7) cfu/g) with an associate Gram-negative flora in varying levels (10(5)-10(7) cfu/g). The addition of nisin and/or a CO2-atmosphere increased the shelf-life to five or six weeks and limited the level of LAB to about 10(4)-10(6), 10(3)-10(6) and 10(2)-10(4) cfu/g, respectively. CO2-atmosphere +/- nisin inhibited the growth of Gram-negative bacteria, whereas nisin had no effect on these in vacuum packages. The Gram-negative flora on vacuum-packed salmon was dominated by a Vibrio sp., resembling V. marinus, Enterobacteriaceae (Enterobacter agglomerans, Serratia liquefaciens and Rahnella aquatilis) and occasionally Aeromonas hydrophila. Irrespective of the addition of nisin and/or CO2-atmosphere, the LAB microflora was dominated by Carnobacterium piscicola, which was found to account for 87% of the 255 LAB isolates characterized. Whole-cell-protein patterns analysed by SDS-PAGE confirmed the Carnobacterium species identification. The spoilage potential of C. piscicola isolates was further studied by inoculation of approx. 10(6) cfu/g in cold-smoked salmon stored at 5 degrees C. The salmon did not spoil within 4 weeks of storage in vacuum- or CO2-atmosphere, and it is concluded that despite high levels (> 10(7) cfu/g) of C. piscicola, sensory rejection was caused by autolytic changes. This was supported by the development of soft texture and sour, rancid and bitter off-flavours at the point of spoilage, irrespective of the length of shelf-life and low or high total counts of LAB and Gram-negative bacteria.

  9. Automated insertion of sequences into a ribosomal RNA alignment: An application of computational linguistics in molecular biology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, R.C.

    This thesis involved the construction of (1) a grammar that incorporates knowledge on base invariancy and secondary structure in a molecule and (2) a parser engine that uses the grammar to position bases into the structural subunits of the molecule. These concepts were combined with a novel pinning technique to form a tool that semi-automates insertion of a new species into the alignment for the 16S rRNA molecule (a component of the ribosome) maintained by Dr. Carl Woese's group at the University of Illinois at Urbana. The tool was tested on species extracted from the alignment and on a groupmore » of entirely new species. The results were very encouraging, and the tool should be substantial aid to the curators of the 16S alignment. The construction of the grammar was itself automated, allowing application of the tool to alignments for other molecules. The logic programming language Prolog was used to construct all programs involved. The computational linguistics approach used here was found to be a useful way to attach the problem of insertion into an alignment.« less

  10. Automated insertion of sequences into a ribosomal RNA alignment: An application of computational linguistics in molecular biology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Ronald C.

    This thesis involved the construction of (1) a grammar that incorporates knowledge on base invariancy and secondary structure in a molecule and (2) a parser engine that uses the grammar to position bases into the structural subunits of the molecule. These concepts were combined with a novel pinning technique to form a tool that semi-automates insertion of a new species into the alignment for the 16S rRNA molecule (a component of the ribosome) maintained by Dr. Carl Woese`s group at the University of Illinois at Urbana. The tool was tested on species extracted from the alignment and on a groupmore » of entirely new species. The results were very encouraging, and the tool should be substantial aid to the curators of the 16S alignment. The construction of the grammar was itself automated, allowing application of the tool to alignments for other molecules. The logic programming language Prolog was used to construct all programs involved. The computational linguistics approach used here was found to be a useful way to attach the problem of insertion into an alignment.« less

  11. Impact of Cervical Sagittal Alignment on Axial Neck Pain and Health-related Quality of Life After Cervical Laminoplasty in Patients With Cervical Spondylotic Myelopathy or Ossification of the Posterior Longitudinal Ligament: A Prospective Comparative Study.

    PubMed

    Fujiwara, Hiroyasu; Oda, Takenori; Makino, Takahiro; Moriguchi, Yu; Yonenobu, Kazuo; Kaito, Takashi

    2018-05-01

    This is prospective observational study. To prospectively investigate the correlation among axial neck pain; a newly developed patient-based quality of life outcome measure, the Japanese Orthopaedic Association Cervical Myelopathy Evaluation Questionnaire (JOACMEQ); and cervical sagittal alignment after open-door laminoplasty for cervical myelopathy. Many studies have focused on postoperative axial neck pain after laminoplasty. However, the correlation among cervical sagittal alignment, neck pain, and JOACMEQ has not been investigated. In total, 57 consecutive patients treated by open-door laminoplasty for cervical myelopathy were included (mean age, 63.7 y; 15 women and 42 men) and divided into 2 groups according to diagnosis [cervical spondylotic myelopathy (CSM) group: 35 patients, and ossification of the posterior longitudinal ligament (OPLL) group: 22 patients]. JOA score, a subdomain of cervical spine function (CSF) in the JOACMEQ, and the visual analog scale for axial neck pain were assessed preoperatively and 12 months postoperatively. Radiographic cervical sagittal parameters were measured by C2 sagittal vertical axis (C2 SVA), C2-C7 lordosis, C7 sagittal slope (C7 slope), and range of motion. C2 SVA values in both groups shifted slightly anteriorly between preoperative and 12-month postoperative measurements (CSM: +19.7±10.9 mm; OPLL: +22.1±13.4 mm vs. CSM: +23.2±16.1 mm; OPLL: +28.7±15.4 mm, respectively). Postoperative axial neck pain in the OPLL group showed strong negative correlations with C2 SVA and C7 slope. Strong negative correlations were found between axial neck pain and CSF in both the preoperative CSM and OPLL groups (CSM: r=-0.45, P=0.01; OPLL: r=-0.61, P<0.01) and between axial neck pain and CSF in the postoperative OPLL group (r=-0.51, P=0.05). This study demonstrated a significant negative correlation between neck pain and CSF in both the CSM and OPLL groups preoperatively and in the OPLL group postoperatively. Radiographic cervical sagittal alignment did not significantly correlate with preoperative or postoperative axial neck pain.

  12. Effects of Schwann cell alignment along the oriented electrospun chitosan nanofibers on nerve regeneration.

    PubMed

    Wang, Wei; Itoh, Soichiro; Konno, Katsumi; Kikkawa, Takeshi; Ichinose, Shizuko; Sakai, Katsuyoshi; Ohkuma, Tsuneo; Watabe, Kazuhiko

    2009-12-15

    We have constructed a chitosan nonwoven nanofiber mesh tube consisting of oriented fibers by the electrospinning method. The efficacy of oriented nanofibers on Schwann cell alignment and positive effect of this tube on peripheral nerve regeneration were confirmed. The physical properties of the chitosan nanofiber mesh sheets prepared by electrospinning with or without fiber orientation were characterized. Then, immortalized Schwann cells were cultured on these sheets. Furthermore, the chitosan nanofiber mesh tubes with or without orientation, and bilayered chitosan mesh tube with an inner layer of oriented nanofibers and an outer layer of randomized nanofibers were bridgegrafted into rat sciatic nerve defect. As a result of fiber orientation, the tensile strength along the axis of the sheet increased. Because Schwann cells aligned along the nanofibers, oriented fibrous sheets could exhibit a Schwann cell column. Functional recovery and electrophysiological recovery occurred in time in the oriented group as well as in the bilayered group, and approximately matched those in the isograft. Furthermore, histological analysis revealed that the sprouting of myelinated axons occurred vigorously followed by axonal maturation in the isograft, oriented, and bilayered group in the order. The oriented chitosan nanofiber mesh tube may be a promising substitute for autogenous nerve graft.

  13. An 8-week thoracic spine stabilization exercise program improves postural back pain, spine alignment, postural sway, and core endurance in university students:a randomized controlled study.

    PubMed

    Toprak Çelenay, Şeyda; Özer Kaya, Derya

    2017-04-18

    To investigate the effects of an 8-week thoracic stabilization exercise program on back pain, spinal alignment, postural sway, and core endurance in university students. University students were randomly allocated into exercise (n: 28) and control (n: 25) groups. The exercise program was carried out 3 days a week for 8 weeks. Postural pain, spinal alignment, postural sway, and core endurance were assessed via visual analogue scale, Spinal Mouse, Biodex Balance System, and McGill's trunk muscle endurance tests at the baseline and after 8 weeks of training. Differences were observed for postural pain, thoracic and lumbar curvature, dynamic stability index (eyes closed), and core endurance scores in the exercise group between baseline and week 8 (P < 0.05) and all the parameters were significantly different when compared to those of the control group (P < 0.05). The program decreased postural pain, spinal curvatures, and postural sway, and increased core endurance in university students. The program can be effective in postural pain and misalignment of spine problems related to core weakness and balance disorders.

  14. Use artificial neural network to align biological ontologies.

    PubMed

    Huang, Jingshan; Dang, Jiangbo; Huhns, Michael N; Zheng, W Jim

    2008-09-16

    Being formal, declarative knowledge representation models, ontologies help to address the problem of imprecise terminologies in biological and biomedical research. However, ontologies constructed under the auspices of the Open Biomedical Ontologies (OBO) group have exhibited a great deal of variety, because different parties can design ontologies according to their own conceptual views of the world. It is therefore becoming critical to align ontologies from different parties. During automated/semi-automated alignment across biological ontologies, different semantic aspects, i.e., concept name, concept properties, and concept relationships, contribute in different degrees to alignment results. Therefore, a vector of weights must be assigned to these semantic aspects. It is not trivial to determine what those weights should be, and current methodologies depend a lot on human heuristics. In this paper, we take an artificial neural network approach to learn and adjust these weights, and thereby support a new ontology alignment algorithm, customized for biological ontologies, with the purpose of avoiding some disadvantages in both rule-based and learning-based aligning algorithms. This approach has been evaluated by aligning two real-world biological ontologies, whose features include huge file size, very few instances, concept names in numerical strings, and others. The promising experiment results verify our proposed hypothesis, i.e., three weights for semantic aspects learned from a subset of concepts are representative of all concepts in the same ontology. Therefore, our method represents a large leap forward towards automating biological ontology alignment.

  15. A practical strategy for the accurate measurement of residual dipolar couplings in strongly aligned small molecules

    NASA Astrophysics Data System (ADS)

    Liu, Yizhou; Cohen, Ryan D.; Martin, Gary E.; Williamson, R. Thomas

    2018-06-01

    Accurate measurement of residual dipolar couplings (RDCs) requires an appropriate degree of alignment in order to optimize data quality. An overly weak alignment yields very small anisotropic data that are susceptible to measurement errors, whereas an overly strong alignment introduces extensive anisotropic effects that severely degrade spectral quality. The ideal alignment amplitude also depends on the specific pulse sequence used for the coupling measurement. In this work, we introduce a practical strategy for the accurate measurement of one-bond 13C-1H RDCs up to a range of ca. -300 to +300 Hz, corresponding to an alignment that is an order of magnitude stronger than typically employed for small molecule structural elucidation. This strong alignment was generated in the mesophase of the commercially available poly-γ-(benzyl-L-glutamate) polymer. The total coupling was measured by the simple and well-studied heteronuclear two-dimensional J-resolved experiment, which performs well in the presence of strong anisotropic effects. In order to unequivocally determine the sign of the total coupling and resolve ambiguities in assigning total couplings in the CH2 group, coupling measurements were conducted at an isotropic condition plus two anisotropic conditions of different alignment amplitudes. Most RDCs could be readily extracted from these measurements whereas more complicated spectral effects resulting from strong homonuclear coupling could be interpreted either theoretically or by simulation. Importantly, measurement of these very large RDCs actually offers significantly improved data quality and utility for the structure determination of small organic molecules.

  16. Multi-profile Bayesian alignment model for LC-MS data analysis with integration of internal standards

    PubMed Central

    Tsai, Tsung-Heng; Tadesse, Mahlet G.; Di Poto, Cristina; Pannell, Lewis K.; Mechref, Yehia; Wang, Yue; Ressom, Habtom W.

    2013-01-01

    Motivation: Liquid chromatography-mass spectrometry (LC-MS) has been widely used for profiling expression levels of biomolecules in various ‘-omic’ studies including proteomics, metabolomics and glycomics. Appropriate LC-MS data preprocessing steps are needed to detect true differences between biological groups. Retention time (RT) alignment, which is required to ensure that ion intensity measurements among multiple LC-MS runs are comparable, is one of the most important yet challenging preprocessing steps. Current alignment approaches estimate RT variability using either single chromatograms or detected peaks, but do not simultaneously take into account the complementary information embedded in the entire LC-MS data. Results: We propose a Bayesian alignment model for LC-MS data analysis. The alignment model provides estimates of the RT variability along with uncertainty measures. The model enables integration of multiple sources of information including internal standards and clustered chromatograms in a mathematically rigorous framework. We apply the model to LC-MS metabolomic, proteomic and glycomic data. The performance of the model is evaluated based on ground-truth data, by measuring correlation of variation, RT difference across runs and peak-matching performance. We demonstrate that Bayesian alignment model improves significantly the RT alignment performance through appropriate integration of relevant information. Availability and implementation: MATLAB code, raw and preprocessed LC-MS data are available at http://omics.georgetown.edu/alignLCMS.html Contact: hwr@georgetown.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:24013927

  17. A comparative study of combined periodontal and orthodontic treatment with fixed appliances and clear aligners in patients with periodontitis.

    PubMed

    Han, Ji-Young

    2015-12-01

    With the increasing prevalence of orthodontic treatment in adults, clear aligner treatments are becoming more popular. The aim of this study was to evaluate the effect of orthodontic treatment on periodontal tissue and to compare orthodontic treatment with fixed appliances (FA) to clear aligner treatment (CAT) in periodontitis patients. A total of 35 patients who underwent orthodontic treatment in the Department of Periodontology were included in this study. After periodontal treatment with meticulous oral hygiene education, patients underwent treatment with FA or CAT, and this study analyzed patient outcomes depending on the treatment strategy. Clinical parameters were assessed at baseline and after orthodontic treatment, and the duration of treatment was compared between these two groups. The overall plaque index, the gingival index, and probing depth improved after orthodontic treatment (P<0.01). The overall bone level also improved (P=0.045). However, the bone level changes in the FA and CAT groups were not significantly different. Significant differences were found between the FA and CAT groups in probing depth, change in probing depth, and duration of treatment (P<0.05). However, no significant differences were found between the FA and CAT groups regarding the plaque index, changes in the plaque index, the gingival index, changes in the gingival index, or changes in the alveolar bone level. The percentage of females in the CAT group (88%) was significantly greater than in the FA group (37%) (P<0.01). After orthodontic treatment, clinical parameters were improved in the FA and CAT groups with meticulous oral hygiene education and plaque control. Regarding plaque index and gingival index, no significant differences were found between these two groups. We suggest that combined periodontal and orthodontic treatment can improve patients' periodontal health irrespective of orthodontic techniques.

  18. Sealed vacuum canister and method for pick-up and containment of material

    DOEpatents

    Stoutenburgh, Roger R.

    1996-01-01

    A vacuum canister including a housing with a sealed vacuum chamber having a predetermined vacuum pressure therein and a valve having a first port for fluid communication with the vacuum chamber and a second port for receiving at least one of a fluid and a particulate material. The valve is operable between a first position to seal the vacuum chamber and retain the predetermined vacuum within the vacuum chamber, and a second position to access the vacuum chamber to permit vacuum fluid flow through the valve from the second port into the vacuum chamber. In operation of the vacuum canister to pick up material with the valve in the second position, when the second port is located adjacent at least one of a fluid and a particulate material, is effective to displace through the valve at least one of a fluid and a particulate material into the housing. The vacuum canister is desirably suitable for picking up and containing hazardous material such as radioactive material, in which the vacuum canister includes a protective layer of lead having a predetermined thickness that is effective to shield radiation emitted from the radioactive material contained within the housing. Advantageously, the vacuum canister includes a vacuum means for establishing a predetermined vacuum pressure within the vacuum chamber.

  19. Sealed vacuum canister and method for pick-up and containment of material

    DOEpatents

    Stoutenburgh, R.R.

    1996-02-13

    A vacuum canister is described including a housing with a sealed vacuum chamber having a predetermined vacuum pressure therein and a valve having a first port for fluid communication with the vacuum chamber and a second port for receiving at least one of a fluid and a particulate material. The valve is operable between a first position to seal the vacuum chamber and retain the predetermined vacuum within the vacuum chamber, and a second position to access the vacuum chamber to permit vacuum fluid flow through the valve from the second port into the vacuum chamber. The vacuum canister, in the operation to pick up material with the valve in the second position, when the second port is located adjacent at least one of a fluid and a particulate material, is effective to displace through the valve at least one of a fluid and a particulate material into the housing. The vacuum canister is desirably suitable for picking up and containing hazardous material such as radioactive material, in which the vacuum canister includes a protective layer of lead having a predetermined thickness that is effective to shield radiation emitted from the radioactive material contained within the housing. Advantageously, the vacuum canister includes a vacuum means for establishing a predetermined vacuum pressure within the vacuum chamber. 6 figs.

  20. Effective Lagrangian in nonlinear electrodynamics and its properties of causality and unitarity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shabad, Anatoly E.; Usov, Vladimir V.

    2011-05-15

    In nonlinear electrodynamics, by implementing the causality principle as the requirement that the group velocity of elementary excitations over a background field should not exceed the speed of light in the vacuum c=1, and the unitarity principle as the requirement that the residue of the propagator should be nonnegative, we establish the positive convexity of the effective Lagrangian on the class of constant fields, also the positivity of all characteristic dielectric and magnetic permittivity constants that are derivatives of the effective Lagrangian with respect to the field invariants. Violation of the general principles by the one-loop approximation in QED atmore » exponentially large magnetic field is analyzed, resulting in complex energy ghosts that signal the instability of the magnetized vacuum. Superluminal excitations (tachyons) appear, too, but for the magnetic field exceeding its instability threshold. Also other popular Lagrangians are tested to establish that the ones leading to spontaneous vacuum magnetization possess wrong convexity.« less

Top