Sample records for guard logging

  1. 46 CFR 148.100 - Log book entries.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Log book entries. 148.100 Section 148.100 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES CARRIAGE OF BULK SOLID MATERIALS THAT REQUIRE SPECIAL HANDLING Minimum Transportation Requirements § 148.100 Log book entries. During...

  2. 46 CFR 148.100 - Log book entries.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Log book entries. 148.100 Section 148.100 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES CARRIAGE OF BULK SOLID MATERIALS THAT REQUIRE SPECIAL HANDLING Minimum Transportation Requirements § 148.100 Log book entries. During...

  3. 46 CFR 148.100 - Log book entries.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Log book entries. 148.100 Section 148.100 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES CARRIAGE OF BULK SOLID MATERIALS THAT REQUIRE SPECIAL HANDLING Minimum Transportation Requirements § 148.100 Log book entries. During...

  4. 46 CFR 148.100 - Log book entries.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Log book entries. 148.100 Section 148.100 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES CARRIAGE OF BULK SOLID MATERIALS THAT REQUIRE SPECIAL HANDLING Minimum Transportation Requirements § 148.100 Log book entries. During...

  5. 15. MEREDITH AVENUE, VIEW WITH LOG RAIL AND BARN. PERHAPS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. MEREDITH AVENUE, VIEW WITH LOG RAIL AND BARN. PERHAPS THE LAST REMAINING EXAMPLE OF CCC BUILT "RUSTIC STYLE" GUARD RAIL IN PARK. VIEW NE. - Gettysburg National Military Park Tour Roads, Gettysburg, Adams County, PA

  6. Installation restoration program. Site investigation report, IRP sites No. 1, No. 2, and No. 3. 106th Civil Engineering Flight, New York Air National Guard, Roslyn Air National Guard Station, Roslyn, New York. Volume 2, Appendices A-G. Site Investigation report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-11-01

    This a continuation of the Installation Restoration Program, Site Investigation Report IRP Sites No. 1, No. 2 and No. 3 at the New York Air National Guard, Roslyn, New York. The soil boring logs are presented.

  7. 46 CFR 131.610 - Logbooks and records.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Logs § 131... them. (d) When a voyage is completed, or after a specified time has elapsed, the master shall file the... alternative log or record for making entries required by law, including regulations in this subchapter. This...

  8. 46 CFR 131.610 - Logbooks and records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Logs § 131... them. (d) When a voyage is completed, or after a specified time has elapsed, the master shall file the... alternative log or record for making entries required by law, including regulations in this subchapter. This...

  9. San Francisco vessel traffic service watchstander analysis

    DOT National Transportation Integrated Search

    1979-11-01

    A team of human factors specialists analyzed the performance of watchstanders in the U.S. Coast Guard's San Francisco Vessel Traffic Center at Yerba Buena Island, San Francisco, California. Data collected included copies of the center's forms and log...

  10. 48. Photographer unknown February 1925 MENDOCINO COUNTY, SECTION K, HIGHWAY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. Photographer unknown February 1925 MENDOCINO COUNTY, SECTION K, HIGHWAY 1. 1-MEN-1-K #39, LOG GUARD RAIL, 2-25. - Redwood National & State Parks Roads, California coast from Crescent City to Trinidad, Crescent City, Del Norte County, CA

  11. New Orleans Vessel Traffic Service Watchstander Analysis

    DOT National Transportation Integrated Search

    1979-05-01

    A team of human factors specialists analyzed the performance of watchstanders in the U.S. Coast Guard Vessel Traffic Center at New Orleans, LA. Data collected included copies of the center's forms and logs, records of watchstander activities for a to...

  12. Puget Sound Vessel Traffic Service Watchstander Analysis

    DOT National Transportation Integrated Search

    1978-11-01

    A team of human factors specialists analyzed the performance of watch-standards in the U.S. Coast Guard's Puget Sound Vessel Traffic Center at Seattle WA. Data collected included copies of the center's forms and logs, records and tapes of watchstande...

  13. 46 CFR 169.807 - Notice of casualty.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Notice of casualty. 169.807 Section 169.807 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS... to mariners, radiograms sent and received, the radio log, and crew, sailing school student...

  14. 46 CFR 169.807 - Notice of casualty.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Notice of casualty. 169.807 Section 169.807 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS... to mariners, radiograms sent and received, the radio log, and crew, sailing school student...

  15. 46 CFR 196.85-1 - Magazine operation and control.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS... shall be inspected daily. Magazine inspection results and corrective action, when taken, shall be noted in the ship's log daily. Maximum and minimum temperatures for the previous 24-hour period shall be...

  16. 46 CFR 167.65-40 - Draft.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Draft. 167.65-40 Section 167.65-40 Shipping COAST GUARD... Requirements § 167.65-40 Draft. The master of every nautical school ship over 50 gross tons shall, whenever leaving port, enter the maximum draft of his nautical school ship in the log book. ...

  17. 46 CFR 167.65-40 - Draft.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Draft. 167.65-40 Section 167.65-40 Shipping COAST GUARD... Requirements § 167.65-40 Draft. The master of every nautical school ship over 50 gross tons shall, whenever leaving port, enter the maximum draft of his nautical school ship in the log book. ...

  18. 46 CFR 167.65-40 - Draft.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Draft. 167.65-40 Section 167.65-40 Shipping COAST GUARD... Requirements § 167.65-40 Draft. The master of every nautical school ship over 50 gross tons shall, whenever leaving port, enter the maximum draft of his nautical school ship in the log book. ...

  19. 46 CFR 167.65-40 - Draft.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Draft. 167.65-40 Section 167.65-40 Shipping COAST GUARD... Requirements § 167.65-40 Draft. The master of every nautical school ship over 50 gross tons shall, whenever leaving port, enter the maximum draft of his nautical school ship in the log book. ...

  20. 46 CFR 167.65-40 - Draft.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Draft. 167.65-40 Section 167.65-40 Shipping COAST GUARD... Requirements § 167.65-40 Draft. The master of every nautical school ship over 50 gross tons shall, whenever leaving port, enter the maximum draft of his nautical school ship in the log book. ...

  1. 75 FR 76688 - Drawbridge Operation Regulation; Isle of Wight (Sinepuxent) Bay, Ocean City, MD

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-09

    ... during the off- season, to do so before the tender office has vacated for the night. The proposed change will ensure draw tender availability for every scheduled opening. The Coast Guard also proposes to... vessels pass. According to the records furnished by MdTA, draw tender logs for the past three years show...

  2. 33 CFR 165.100 - Regulated Navigation Area: Navigable waters within the First Coast Guard District.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... destination(s). (C) Current and forecasted weather, including visibility, wind, and sea state for the... visibility, wind, and sea state. This information may be entered in either the voyage plan or towing vessel's log book. (C) The channels of VHF radio to monitor. (D) Other considerations such as availability of...

  3. 33 CFR 165.100 - Regulated Navigation Area: Navigable waters within the First Coast Guard District.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... destination(s). (C) Current and forecasted weather, including visibility, wind, and sea state for the... visibility, wind, and sea state. This information may be entered in either the voyage plan or towing vessel's log book. (C) The channels of VHF radio to monitor. (D) Other considerations such as availability of...

  4. 33 CFR 165.100 - Regulated Navigation Area: Navigable waters within the First Coast Guard District.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... destination(s). (C) Current and forecasted weather, including visibility, wind, and sea state for the... visibility, wind, and sea state. This information may be entered in either the voyage plan or towing vessel's log book. (C) The channels of VHF radio to monitor. (D) Other considerations such as availability of...

  5. 76 FR 75505 - Drawbridge Operation Regulation; Gulf Intracoastal Waterway (Algiers Alternate Route), Belle...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-02

    ... vehicles (40%) commuted across the bridge during the same times. Thus, a substantial delay can occur to vehicular traffic during the morning and afternoon heavy commute periods. The proposed change would allow... will be in effect from December 19, 2011 until January 17, 2012. The Coast Guard will review the logs...

  6. Installation-restoration program, Phase 2. Confirmation/quantification Stage 1 for Otis Air National Guard Base, Massachusetts, Air National Guard Support Center, Andrews Air Force Base, Maryland. Volume 2. Appendices. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1985-10-01

    The purpose of this task is to determine if environmental contamination has resulted from waste disposal practices at Otis ANGB MA; to provide estimates of the magnitude and extent of contamination, should contamination be found; to identify potential environmental consequences of migrating pollutants; to identify any additional investigations and their attendant costs necessary to identify the magnitude, extent and direction of movement of discovered contaminants. Partial contents include: well and test pit logs; site safety plan; laboratory analytical methods and quality assurance; and Federal and state drinking water and human health standards applicable in Massachusetts.

  7. AVTA Federal Fleet PEV Readiness Data Logging and Characterization Study for United States Coast Guard Headquarters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schey, Stephen; Francfort, Jim

    2015-05-01

    Federal agencies are mandated to purchase alternative fuel vehicles, increase consumption of alternative fuels, and reduce petroleum consumption. Available plug-in electric vehicles (PEVs) provide an attractive option in the selection of alternative fuel vehicles. PEVs, which consist of both battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs), have significant advantages over internal combustion engine (ICE) vehicles in terms of energy efficiency, reduced petroleum consumption, and reduced production of greenhouse gas (GHG) emissions, and they provide performance benefits with quieter, smoother operation. This study intended to evaluate the extent to which the United States Coast Guard Headquarters (USCG HQ)more » could convert part or all of their fleet of vehicles from petroleum-fueled vehicles to PEVs.« less

  8. Evaluating the Tradeoffs Between Dollars Spent and Lives saved in Military Settings

    DTIC Science & Technology

    2013-11-18

    data needed , and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this...Programs that improve workplace safety have costs. Firms may need to purchase additional equipment or protective devices, install machine guards...employers the costs may be slight. Because of the inherent dangers in production, firms in mining, logging, fishing, and construction will need to

  9. Installation Restoration Program. Volume 2. 110th Fighter Group Michigan Air National Guard, W.K. Kellogg Memorial Airport, Battle Creek, Michigan

    DTIC Science & Technology

    1993-11-01

    RECOMMENDATIONS SECTION 7 REFERENCES APPENDIX A MONITORING WELL CONSTRUCTION RECORDS AND BORING LOGS APPENDIX B SOIL BORING LOGS 3 APPENDIX C ...0.25 .o000 2- C *LUOEITNYL VINYL ETNEE NA i2/o/U NP 0. 131.0ICNLORMTNMIE NA 12/OS/IS 0.35 0.0S 1.000 DIOCULUSUGRTNAN NA 12/OS/US a 0.45 1.000 ¶ ,2...12l/Sm a 10.001011 kS kfue(K)I m ot~b 12/09/ 12/fl/U a 10.00 1.005 ugejpvu 12/09/ tZ/3U 0 10.0 1 .M E, I c . ce 4Z- CR0ESFENGINEERING SCIENCE 135-073

  10. Application of ozonated dry ice (ALIGAL™ Blue Ice) for packaging and transport in the food industry.

    PubMed

    Fratamico, Pina M; Juneja, Vijay; Annous, Bassam A; Rasanayagam, Vasuhi; Sundar, M; Braithwaite, David; Fisher, Steven

    2012-05-01

    Dry ice is used by meat and poultry processors for temperature reduction during processing and for temperature maintenance during transportation. ALIGAL™ Blue Ice (ABI), which combines the antimicrobial effect of ozone (O(3)) along with the high cooling capacity of dry ice, was investigated for its effect on bacterial reduction in air, in liquid, and on food and glass surfaces. Through proprietary means, O(3) was introduced to produce dry ice pellets to a concentration of 20 parts per million (ppm) by total weight. The ABI sublimation rate was similar to that of dry ice pellets under identical conditions, and ABI was able to hold the O(3) concentration throughout the normal shelf life of the product. Challenge studies were performed using different microorganisms, including E. coli, Campylobacter jejuni, Salmonella, and Listeria, that are critical to food safety. ABI showed significant (P < 0.05) microbial reduction during bioaerosol contamination (up to 5-log reduction of E. coli and Listeria), on chicken breast (approximately 1.3-log reduction of C. jejuni), on contact surfaces (approximately 3.9 log reduction of C. jejuni), and in liquid (2-log reduction of C. jejuni). Considering the stability of O(3), ease of use, and antimicrobial efficacy against foodborne pathogens, our results suggest that ABI is a better alternative, especially for meat and poultry processors, as compared to dry ice. Further, ABI can potentially serve as an additional processing hurdle to guard against pathogens during processing, transportation, distribution, and/or storage. © 2012 Institute of Food Technologists®

  11. Installation restoration program. Site investigation report. Revision 4. Volume 2: Appendix B through Appendix E. 155th Air Refueling Group, Nebraska Air National Guard, Lincoln Municipal Airport, Lincoln, Nebraska. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-04-01

    This is Site investigation Report, Volume 2 Appendix B through E. A Site Investigation was performed at the 155th Air Refueling Group at Lincoln, NE to evaluate six areas of suspected contamination identified during a Preliminary Assessment. The sites that this investigation were conducted at are: Site 1 - Fuel Farm, POL Storage Area Site 2 - West End of Old Oak Creek, Site 3 - Former Tank Cleaning/Hazardous Waste Storage Area, Site 4 - Access Road, Dust Control Area, Site 5 - Army National Guard Oil Storage Area, and Site 6 - Hydraulic Pressure Check Unit Storage Area. Themore » report recommended no further action for Sites 3 through 6 due to low levels or no contamination being found. The report recommended that the portion of Site 2 that is located downstream of Site 1 should be included in Site 1. Appendix 2 consist of the following appendix: Well Data and Geologic Boring Logs (Appendix B), Survey Data (Appendix C), Quality Control (Appendix D), and Analytical Results (Appendix E).« less

  12. Anger Problems and Posttraumatic Stress Disorder in Male and Female National Guard and Reserve Service Members

    PubMed Central

    Worthen, Miranda; Rathod, Sujit D.; Cohen, Gregory; Sampson, Laura; Ursano, Robert; Gifford, Robert; Fullerton, Carol; Galea, Sandro; Ahern, Jennifer

    2014-01-01

    Anger is a common problem among veterans and has been associated with posttraumatic stress disorder (PTSD). This study aimed to improve understanding of how anger and PTSD co-occur by examining gender differences and differences by whether the triggering traumatic event is deployment-related vs. civilian-related in current service members. A representative cohort of Reserve and National Guard service personnel (n = 1,293) were interviewed to assess for deployment- or civilian-related traumas, PTSD, and anger. The prevalence of self-reported anger problems was estimated among male (n = 1,036) and female (n = 257) service members. Log Poisson regression models with robust standard errors were used to estimate the associations of problems with anger with PTSD and PTSD symptom severity for men and women. Self-reported anger problems were common among male (53.0%) and female (51.3%) service members. Adjusted prevalence ratios (PR) showed associations between anger and PTSD connected to both civilian- and deployment-related traumas (PR were 1.77 (95% CI 1.52 – 2.05) and 1.85 (95% CI 1.62 – 2.12), respectively). PTSD symptom severity was also associated with anger. This study was cross-sectional and so a causal relationship between PTSD and anger cannot be established. Problems with anger are common among male and female current Guard and Reserve members. These findings suggest that anger treatment should be made available to current service members and that clinicians should assess anger problems irrespective of gender. Future research should examine the effectiveness of anger treatment protocols by gender. PMID:24755257

  13. Influence of Cooling Rate on Growth of Bacillus cereus from Spore Inocula in Cooked Rice, Beans, Pasta, and Combination Products Containing Meat or Poultry.

    PubMed

    Juneja, Vijay K; Mohr, Tim B; Silverman, Meryl; Snyder, O Peter

    2018-02-23

    The objective of this study was to assess the ability of Bacillus cereus spores to germinate and grow in order to determine a safe cooling rate for cooked rice, beans, and pasta, rice-chicken (4:1), rice-chicken-vegetables (3:1:1), rice-beef (4:1), and rice-beef-vegetables (3:1:1). Samples were inoculated with a cocktail of four strains of heat-shocked (80°C for 10 min) B. cereus spores (NCTC 11143, 935A/74, Brad 1, and Mac 1) to obtain a final spore concentration of approximately 2 log CFU/g. Thereafter, samples were exponentially cooled through the temperature range of 54.5 to 7.2°C in 6, 9, 12, 15, 18, and 21 h. At the end of the cooling period, samples were removed and plated on mannitol egg yolk polymyxin agar. The plates were incubated at 30°C for 24 h. The net B. cereus growth from spores in beans was <1 log after 9 h of cooling, but the pathogen grew faster in rice and pasta. In combination products, the net growth was as follows: 3.05, 3.89, and 4.91 log CFU/g in rice-chicken; 3.49, 4.28, and 4.96 log CFU/g in rice-beef; 3.50, 4.20, and 5.32 CFU/g in rice-chicken-mixed vegetables; and 3.68, 4.44, and 5.25 CFU/g in rice-beef-mixed vegetables after 15, 18, and 21 h of cooling, respectively. This study suggests safe cooling rates for cooling cooked rice, beans, pasta, rice-chicken, rice-chicken-vegetables, rice-beef, and rice-beef-vegetables to guard against the hazards associated with B. cereus.

  14. Anger problems and posttraumatic stress disorder in male and female National Guard and Reserve Service members.

    PubMed

    Worthen, Miranda; Rathod, Sujit D; Cohen, Gregory; Sampson, Laura; Ursano, Robert; Gifford, Robert; Fullerton, Carol; Galea, Sandro; Ahern, Jennifer

    2014-08-01

    Anger is a common problem among veterans and has been associated with posttraumatic stress disorder (PTSD). This study aimed to improve understanding of how anger and PTSD co-occur by examining gender differences and differences by whether the triggering traumatic event is deployment-related vs. civilian-related in current service members. A representative cohort of Reserve and National Guard service personnel (n = 1293) were interviewed to assess for deployment- or civilian-related traumas, PTSD, and anger. The prevalence of self-reported anger problems was estimated among male (n = 1036) and female (n = 257) service members. Log Poisson regression models with robust standard errors were used to estimate the associations of problems with anger with PTSD and PTSD symptom severity for men and women. Self-reported anger problems were common among male (53.0%) and female (51.3%) service members. Adjusted prevalence ratios (PR) showed associations between anger and PTSD connected to both civilian- and deployment-related traumas (PR were 1.77 (95% CI 1.52-2.05) and 1.85 (95% CI 1.62-2.12), respectively). PTSD symptom severity was also associated with anger. This study was cross-sectional and so a causal relationship between PTSD and anger cannot be established. Problems with anger are common among male and female current Guard and Reserve members. These findings suggest that anger treatment should be made available to current service members and that clinicians should assess anger problems irrespective of gender. Future research should examine the effectiveness of anger treatment protocols by gender. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Course and outcome of accidental sodium hydroxide ocular injury.

    PubMed

    Sharma, Namrata; Singh, Digvijay; Sobti, Amit; Agarwal, Prakashchand; Velpandian, Thirumurthy; Titiyal, Jeewan S; Ghose, Supriyo

    2012-10-01

    To evaluate the course and outcome of patients with accidental ocular alkali burns. Prospective, interventional case series. Study of a cohort of 16 patients (31 eyes) who sustained concomitant accidental sodium hydroxide ocular burns and received appropriate treatment at a tertiary care eye hospital in India. The patients were followed up for 1 year, and parameters including best-corrected visual acuity, epithelial defect area, conjunctival and limbal involvement, and injury-related complications were evaluated. Severe sodium hydroxide exposure of a mean duration of 12 ± 2.5 minutes and delay in specialist eye care caused moderate to severe injury (grade II, 19% [n = 6]; grade III, 19% [n = 6]; grade IV, 10% [n = 3]; and grade VI, 52% [n = 16]). Median best-corrected visual acuity at presentation was 1.0 logarithm of the minimal angle of resolution (logMAR) units (range, 0.3 to 1.9 logMAR units), and at 1 year, it was 1.0 logMAR units (range, 0 to 1.9 logMAR units; P = .121). The median initial epithelial defect was 100 mm(2) (range, 18 to 121 mm(2)), which healed in all eyes by 3.5 months. Initial median limbal involvement was 12 clock hours (range, 3 to 12 clock hours), resulting in a residual limbal stem cell deficiency of 6 clock hours (range, 0 to 12 clock hours) at 1 year. Most common complications were glaucoma and cataract. Corneal ulcers developed in 2 eyes, and keratolimbal graft was performed in 1 patient. Grade VI injuries had significantly worse outcome than the lower-grade injuries. The course and outcome of ocular alkali burns depends on effective first aid (including a thorough eyewash), age, initial grade of injury, response to treatment, prevention of secondary infection, and control of glaucoma. Despite appropriate treatment, these eyes responded poorly and carried a guarded visual prognosis. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  17. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  18. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  19. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  20. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  1. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  2. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  3. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  4. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  5. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  6. National Guard > About the Guard > Today in Guard History

    Science.gov Websites

    National Guard About Us By the Numbers Contact Us FAQ Federal Mission History Join Us Leaders Director of March Today in Guard History Leadership CNGB VCNGB SEA DANG DARNG Joint Staff J-1 J-2 J-3 J-4 J-5 J-6 J ARNG Readiness Home : About the Guard : Today in Guard History Today in Guard History Browse history by

  7. 33 CFR 23.10 - Coast Guard emblem.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ring all outlined in medium blue (Coast Guard blue), letters and numerals medium blue (Coast Guard blue), white area within ring, shield with medium blue (Coast Guard blue) chief and 13 alternating white and red (Coast Guard red) stripes (7 white and 6 red) with narrow medium blue (Coast Guard blue) outline...

  8. 33 CFR 23.10 - Coast Guard emblem.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ring all outlined in medium blue (Coast Guard blue), letters and numerals medium blue (Coast Guard blue), white area within ring, shield with medium blue (Coast Guard blue) chief and 13 alternating white and red (Coast Guard red) stripes (7 white and 6 red) with narrow medium blue (Coast Guard blue) outline...

  9. 33 CFR 23.10 - Coast Guard emblem.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ring all outlined in medium blue (Coast Guard blue), letters and numerals medium blue (Coast Guard blue), white area within ring, shield with medium blue (Coast Guard blue) chief and 13 alternating white and red (Coast Guard red) stripes (7 white and 6 red) with narrow medium blue (Coast Guard blue) outline...

  10. 33 CFR 23.10 - Coast Guard emblem.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ring all outlined in medium blue (Coast Guard blue), letters and numerals medium blue (Coast Guard blue), white area within ring, shield with medium blue (Coast Guard blue) chief and 13 alternating white and red (Coast Guard red) stripes (7 white and 6 red) with narrow medium blue (Coast Guard blue) outline...

  11. 33 CFR 23.10 - Coast Guard emblem.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ring all outlined in medium blue (Coast Guard blue), letters and numerals medium blue (Coast Guard blue), white area within ring, shield with medium blue (Coast Guard blue) chief and 13 alternating white and red (Coast Guard red) stripes (7 white and 6 red) with narrow medium blue (Coast Guard blue) outline...

  12. The Impact of Excluding Food Guarding from a Standardized Behavioral Canine Assessment in Animal Shelters

    PubMed Central

    Mohan-Gibbons, Heather; Dolan, Emily D.; Reid, Pamela; Slater, Margaret R.; Mulligan, Hugh; Weiss, Emily

    2018-01-01

    Simple Summary Recent research has called into question the value of the food guarding assessment as a predictive tool for determining the safety of shelter dogs. This study examined the effect of eliminating the food guarding assessment in nine U.S. animal shelters. It was found that when the food guarding assessment was removed, bites or other injuries to staff or adopters did not increase. However, dogs exhibiting food guarding behavior were less likely to be adopted, had a longer shelter stay, and were more likely to be euthanized than dogs in the general population. Based on previous research and this study’s findings, the authors recommend that shelters discontinue the food guarding assessment. Abstract Many shelters euthanize or restrict adoptions for dogs that exhibit food guarding while in the animal shelter. However, previous research showed that only half the dogs exhibiting food guarding during an assessment food guard in the home. So, dogs are often misidentified as future food guarders during shelter assessments. We examined the impact of shelters omitting food guarding assessments. Nine shelters conducted a two-month baseline period of assessing for food guarding followed by a two-month investigative period during which they omitted the food guarding assessment. Dogs that guarded their food during a standardized assessment were less likely to be adopted, had a longer shelter stay, and were more likely to be euthanized. When the shelters stopped assessing for food guarding, there was no significant difference in the rate of returns of food guarding dogs, even though more dogs were adopted because fewer were identified with food guarding behavior. Additionally, the number of injuries to staff, volunteers, and adopters was low (104 incidents from a total of 14,180 dogs) and did not change when the food guarding assessment was omitted. These results support a recommendation that shelters discontinue the food guarding assessment. PMID:29419746

  13. 33 CFR 334.783 - Arlington Channel, U.S. Coast Guard Base Mobile, Mobile, Alabama, Coast Guard restricted area.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Guard Base Mobile, Mobile, Alabama, Coast Guard restricted area. 334.783 Section 334.783 Navigation and... RESTRICTED AREA REGULATIONS § 334.783 Arlington Channel, U.S. Coast Guard Base Mobile, Mobile, Alabama, Coast... without prior approval from the Commanding Officer, U.S. Coast Guard Group Mobile or his designated...

  14. How We Began - About the Guard - The National Guard

    Science.gov Websites

    Partnership Program Special Features Your National Guard About the Guard How We Began Air National Guard Army National Guard About Us By the Numbers Contact Us FAQ Federal Mission History Join Us Leaders Director of the ARNG Deputy Director of the ARNG Chief of Staff of the ARNG Command Chief Warrant Officer of the

  15. Air National Guard Financial Reports on the National Guard and Reserve Equipment Appropriation.

    DTIC Science & Technology

    1997-12-16

    consolidated financial statements for FY 1996 and each succeeding year. In 1981, Congress established the National Guard and Reserve Equipment Appropriation to provide the equipment needed to maintain the readiness of the National Guard and Reserve units. In FY 1996, the Air National Guard received a total of $260.4 million for National Guard and Reserve Equipment programs, The Defense Finance

  16. A Comparison of the Fit between the Organizational Climate of the Coast Guard, the Job/Career Expectations of Black College Graduates, and Their Perceptions about the Coast Guard.

    DTIC Science & Technology

    1980-12-01

    ORGANIZA- TIONAL CLIMATE OF THE COAST GUARD, THE JOB/ CAREER EXPECTATIONS OF BLACK COLLEGE GRADUATES AND THEIR PERCEPTIONS ABOUT THE COAST GUARD by... climate of the Coast Guard. Their perceptions about the Coast Guard are generally positive. Their expectaticns were higher than their perceptions . Thus the... perceptions and expectations of Black college graduates were generally higher than all Coast Guard officers’ view of the organizational climate of the

  17. Sex and Occupational Socialization among Prison Guards: A Longitudinal Study.

    ERIC Educational Resources Information Center

    Crouch, Ben M.; Alpert, Geoffrey P.

    1982-01-01

    Reports changes in attitudes of male and female prison guards over the first six months on the job. Found male guards became more, and female guards became less, punitive and aggressive. Results appear to derive from differences in the work milieu of male and female guards. (Author/JAC)

  18. 46 CFR 177.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Guards in vehicle spaces. 177.940 Section 177.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.940 Guards in vehicle spaces. On a vessel...

  19. 46 CFR 177.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Guards in vehicle spaces. 177.940 Section 177.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.940 Guards in vehicle spaces. On a vessel...

  20. 46 CFR 177.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Guards in vehicle spaces. 177.940 Section 177.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.940 Guards in vehicle spaces. On a vessel...

  1. 46 CFR 177.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Guards in vehicle spaces. 177.940 Section 177.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.940 Guards in vehicle spaces. On a vessel...

  2. 46 CFR 177.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Guards in vehicle spaces. 177.940 Section 177.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.940 Guards in vehicle spaces. On a vessel...

  3. 46 CFR 169.331 - Guards in hazardous locations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Guards in hazardous locations. 169.331 Section 169.331 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Construction and Arrangement Rails and Guards § 169.331 Guards in hazardous locations. Each exposed hazard...

  4. 46 CFR 190.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Guards in dangerous places. 190.25-15 Section 190.25-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS CONSTRUCTION AND ARRANGEMENT Rails and Guards § 190.25-15 Guards in dangerous places. (a) Suitable hand covers...

  5. 46 CFR 169.331 - Guards in hazardous locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Guards in hazardous locations. 169.331 Section 169.331 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Construction and Arrangement Rails and Guards § 169.331 Guards in hazardous locations. Each exposed hazard...

  6. Do school crossing guards make crossing roads safer? A quasi-experimental study of pedestrian-motor vehicle collisions in Toronto, Canada.

    PubMed

    Rothman, Linda; Perry, Daniel; Buliung, Ron; Macarthur, Colin; To, Teresa; Macpherson, Alison; Larsen, Kristian; Howard, Andrew

    2015-07-31

    The presence of school crossing guards has been associated with more walking and more pedestrian-motor vehicle collisions (PMVCs) in area-level cross-sectional analyses. The objectives of the study were to (1) Determine the effect on PMVC rates of newly implemented crossing guards in Toronto, Canada (2) Determine where collisions were located in relation to crossing guards throughout the city, and whether they occurred during school travel times. School crossing guards with 50 m buffers were mapped along with police-reported child PMVCs from 2000-2011. (1) A quasi-experimental study identified all age collision counts near newly implemented guards before and after implementation, modeled using repeated measures Poisson regression adjusted for season and built environment variables. (2) A retrospective cohort study of all child PMVCS throughout the city to determine the proportions of child PMVCs which occurred during school travel times and at guard locations. There were 27,827 PMVCs, with 260 PMVCs at the locations of 58 newly implemented guards. Repeated measures adjusted Poisson regression found PMVCs rates remained unchanged at guard locations after implementation (IRR 1.02, 95 % CI 0.74, 1.39). There were 568 guards citywide with 1850 child PMVCs that occurred at guard locations. The majority of child PMVCs occurred outside school travel times (n = 1155, 62 %) and of those that occurred during school travel times, only 95 (13.7 %) were at a guard location. School crossing guards are a simple roadway modification to increase walking to school without apparent detrimental safety effects. Other more permanent interventions are necessary to address the frequency of child PMVCs occurring away from the location of crossing guards, and outside of school travel times.

  7. 30 CFR 57.12080 - Bare conductor guards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bare conductor guards. 57.12080 Section 57... Underground Only § 57.12080 Bare conductor guards. Trolley wires and bare power conductors shall be guarded at... conductors are less than 7 feet above the rail, they shall be guarded at all points where persons work or...

  8. 30 CFR 57.12080 - Bare conductor guards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Bare conductor guards. 57.12080 Section 57... Underground Only § 57.12080 Bare conductor guards. Trolley wires and bare power conductors shall be guarded at... conductors are less than 7 feet above the rail, they shall be guarded at all points where persons work or...

  9. 46 CFR 127.330 - Guards in dangerous places.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Guards in dangerous places. 127.330 Section 127.330... ARRANGEMENTS Rails and Guards § 127.330 Guards in dangerous places. Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place, such as gears of rotating machinery, and hot...

  10. 46 CFR 127.330 - Guards in dangerous places.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Guards in dangerous places. 127.330 Section 127.330... ARRANGEMENTS Rails and Guards § 127.330 Guards in dangerous places. Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place, such as gears of rotating machinery, and hot...

  11. 46 CFR 127.330 - Guards in dangerous places.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Guards in dangerous places. 127.330 Section 127.330... ARRANGEMENTS Rails and Guards § 127.330 Guards in dangerous places. Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place, such as gears of rotating machinery, and hot...

  12. 46 CFR 127.330 - Guards in dangerous places.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Guards in dangerous places. 127.330 Section 127.330... ARRANGEMENTS Rails and Guards § 127.330 Guards in dangerous places. Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place, such as gears of rotating machinery, and hot...

  13. 46 CFR 127.330 - Guards in dangerous places.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Guards in dangerous places. 127.330 Section 127.330... ARRANGEMENTS Rails and Guards § 127.330 Guards in dangerous places. Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place, such as gears of rotating machinery, and hot...

  14. 46 CFR 116.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Guards in vehicle spaces. 116.940 Section 116.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.940 Guards in vehicle spaces. On a vessel authorized to carry one or more...

  15. 46 CFR 116.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Guards in vehicle spaces. 116.940 Section 116.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.940 Guards in vehicle spaces. On a vessel authorized to carry one or more...

  16. 46 CFR 116.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Guards in vehicle spaces. 116.940 Section 116.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.940 Guards in vehicle spaces. On a vessel authorized to carry one or more...

  17. 46 CFR 116.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Guards in vehicle spaces. 116.940 Section 116.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.940 Guards in vehicle spaces. On a vessel authorized to carry one or more...

  18. 46 CFR 116.940 - Guards in vehicle spaces.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Guards in vehicle spaces. 116.940 Section 116.940 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE... ARRANGEMENT Rails and Guards § 116.940 Guards in vehicle spaces. On a vessel authorized to carry one or more...

  19. 46 CFR 50.10-25 - Coast Guard Symbol.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Coast Guard Symbol. 50.10-25 Section 50.10-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 50.10-25 Coast Guard Symbol. (a) The term Coast Guard Symbol...

  20. 78 FR 55214 - Annual Marine Events in the Eighth Coast Guard District, Sabine River; Orange, TX

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-10

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 100 [Docket No. USCG-2013-0723] Annual Marine Events in the Eighth Coast Guard District, Sabine River; Orange, TX AGENCY: Coast Guard, DHS. ACTION: Notice of enforcement of regulation. SUMMARY: The Coast Guard will enforce Special Local...

  1. REQUEST A COLOR GUARD

    Science.gov Websites

    EMERGENCY PREPAREDNESS CONTACT REQUEST A SPEAKER REQUEST A COLOR GUARD OPERATIONAL CONTRACT SUPPORT HomeCONTACTREQUEST A COLOR GUARD Request a Color Guard Please take a moment to fill out the document at the link one month to process your request, but no more than three. Color Guard Request Form For Community

  2. 46 CFR 72.40-20 - Guards in dangerous places.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Guards in dangerous places. 72.40-20 Section 72.40-20... ARRANGEMENT Rails and Guards § 72.40-20 Guards in dangerous places. (a) Suitable covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. (b...

  3. 46 CFR 92.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Guards in dangerous places. 92.25-15 Section 92.25-15... CONSTRUCTION AND ARRANGEMENT Rails and Guards § 92.25-15 Guards in dangerous places. (a) Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery...

  4. 46 CFR 72.40-20 - Guards in dangerous places.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Guards in dangerous places. 72.40-20 Section 72.40-20... ARRANGEMENT Rails and Guards § 72.40-20 Guards in dangerous places. (a) Suitable covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. (b...

  5. 46 CFR 72.40-20 - Guards in dangerous places.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Guards in dangerous places. 72.40-20 Section 72.40-20... ARRANGEMENT Rails and Guards § 72.40-20 Guards in dangerous places. (a) Suitable covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. (b...

  6. 46 CFR 190.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Guards in dangerous places. 190.25-15 Section 190.25-15... CONSTRUCTION AND ARRANGEMENT Rails and Guards § 190.25-15 Guards in dangerous places. (a) Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery...

  7. 46 CFR 72.40-20 - Guards in dangerous places.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Guards in dangerous places. 72.40-20 Section 72.40-20... ARRANGEMENT Rails and Guards § 72.40-20 Guards in dangerous places. (a) Suitable covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. (b...

  8. 46 CFR 92.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Guards in dangerous places. 92.25-15 Section 92.25-15... CONSTRUCTION AND ARRANGEMENT Rails and Guards § 92.25-15 Guards in dangerous places. (a) Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery...

  9. 46 CFR 190.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Guards in dangerous places. 190.25-15 Section 190.25-15... CONSTRUCTION AND ARRANGEMENT Rails and Guards § 190.25-15 Guards in dangerous places. (a) Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery...

  10. 46 CFR 72.40-20 - Guards in dangerous places.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Guards in dangerous places. 72.40-20 Section 72.40-20... ARRANGEMENT Rails and Guards § 72.40-20 Guards in dangerous places. (a) Suitable covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. (b...

  11. 46 CFR 92.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Guards in dangerous places. 92.25-15 Section 92.25-15... CONSTRUCTION AND ARRANGEMENT Rails and Guards § 92.25-15 Guards in dangerous places. (a) Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery...

  12. 46 CFR 190.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Guards in dangerous places. 190.25-15 Section 190.25-15... CONSTRUCTION AND ARRANGEMENT Rails and Guards § 190.25-15 Guards in dangerous places. (a) Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery...

  13. 46 CFR 92.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Guards in dangerous places. 92.25-15 Section 92.25-15... CONSTRUCTION AND ARRANGEMENT Rails and Guards § 92.25-15 Guards in dangerous places. (a) Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery...

  14. 46 CFR 92.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Guards in dangerous places. 92.25-15 Section 92.25-15... CONSTRUCTION AND ARRANGEMENT Rails and Guards § 92.25-15 Guards in dangerous places. (a) Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery...

  15. 46 CFR 190.25-15 - Guards in dangerous places.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Guards in dangerous places. 190.25-15 Section 190.25-15... CONSTRUCTION AND ARRANGEMENT Rails and Guards § 190.25-15 Guards in dangerous places. (a) Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery...

  16. 5. AERIAL VIEW TO NORTHEAST OF ENTIRE COAST GUARD AIR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. AERIAL VIEW TO NORTHEAST OF ENTIRE COAST GUARD AIR STATION SAN FRANCISCO. 8X10 black and white silver gelatin print. United States Coast Guard Official Photograph, 12th Coast Guard District, San Francisco. 1960. - U.S. Coast Guard Air Station San Francisco, 1020 North Access Road, San Francisco, San Francisco County, CA

  17. Guard News - The National Guard

    Science.gov Websites

    inspected, prepped and worked on to... MORE Female Texas Army National Guard pilot defies limits May 25 in which a chemical attack occurred. Female Texas Army National Guard pilot defies limits News

  18. DefenseLink Special: Blum Visits 'Operation Jump Start' Troops

    Science.gov Websites

    DEMING, N.M., Dec. 1, 2006 - The National Guard Bureau chief got a look this week at how the forward , 2006 - The National Guard Bureau chief assured members of the Army and Air National Guard during a Guard troops serving here along the southwestern U.S. border. Story Guard Chief, Border Patrol Praise

  19. Fact Sheets - The National Guard

    Science.gov Websites

    National Guard About Us By the Numbers Contact Us FAQ Federal Mission History Join Us Leaders Director of March Today in Guard History Leadership CNGB VCNGB SEA DANG DARNG Joint Staff J-1 J-2 J-3 J-4 J-5 J-6 J ARNG Readiness Home : Resources : Fact Sheets General Information Air Guard History Army National Guard

  20. Installation Restoration Program (IRP) Site Investigation Report for IRP Site Number 4. Volume 3. Appendices D-I. 128th Air Refueling Wing, Wisconsin Air National Guard, General Billy Mitchell Field Air National Guard Base, Milwaukee, Wisconsin.

    DTIC Science & Technology

    1996-03-01

    NATIONAL GUARD GENERAL BILLY MITCHELL FIELD AIR NATIONAL GUARD BASE MILWAUKEE, WISCONSIN MARCH 1996 ______ 19960509 134 HQ ANG/CEVR ANDREWS AFB...Report for IRP Site No. 4, Wisconsin Air National Guard, 128th Air Refueling Wing, General Billy Mitchell Field, Milwaukee, Wisconsin - Volume III...Wisconsin Air National Guard, 128th Air Refueling Wing, General Billy Mitchell Field, Milwaukee, Wisconsin, Volume III - Appendices D-I. This is the

  1. Truck side guard specifications : recommended standard

    DOT National Transportation Integrated Search

    2016-09-01

    This document is intended to be used by (1) public or private medium/heavy-duty truck fleets considering adding side guards; (2) jurisdictions or customers that require side guards through policy or procurement; (3) manufacturers of side guards; and ...

  2. The natural history of nest defence in a stingless bee, Tetragonisca angustula (Latreille) (Hymenoptera: Apidae), with two distinct types of entrance guards.

    PubMed

    Grüter, C; Kärcher, M H; Ratnieks, F L W

    2011-01-01

    The stingless bee Tetragonsica angustula (Latreille) is the only social bee known that has two different types of nest entrance guards. As in other stingless bees and the honey bee one type stands on, in or near the nest entrance. The second type, so far only known in T. angustula, hovers near the nest entrance. In order to gain further understanding of this unique situation we studied guarding behaviour in both types of guards. Using marked bees, we found that individual worker bees guarded for a long time, up to 20 days, relative to their short, average c. 21 day, lifespan. Relatively few, 33%, individually marked guards were seen performing both types of guarding. The others only acted as standing guards. The bees that did perform both types did so over similar periods of their life. Hovering bouts were 57 min long, interrupted by breaks inside the hive of a few minutes (3.3 ± 1.5 min). Standing bouts were slightly longer (74 min) and also interrupted by short breaks (7.82 ± 6.45 min). Human breath, mimicking a vertebrate intruder, caused the guards to retreat into the nest rather than to attack the intruder. Some colonies protected themselves against intruders by closing the entrance during the night (32% and 56% of colonies during two nights). In summary, our results indicate that nest entrance guarding in T. angustula involves division of labour between the two types, in which most guarding individuals only act as standing guards.

  3. Use of Head Guards in AIBA Boxing Tournaments-A Cross-Sectional Observational Study.

    PubMed

    Loosemore, Michael P; Butler, Charles F; Khadri, Abdelhamid; McDonagh, David; Patel, Vimal A; Bailes, Julian E

    2017-01-01

    This study looks at the changes in injuries after the implementation of a new rule by the International Boxing Association (AIBA) to remove head guards from its competitions. A cross-sectional observational study performed prospectively. This brief report examines the removal of head guards in 2 different ways. The first was to examine the stoppages due to blows to the head by comparing World Series Boxing (WSB), without head guards, to other AIBA competitions with head guards. Secondly, we examined the last 3 world championships: 2009 and 2011 (with head guards) and 2013 (without head guards). World Series Boxing and AIBA world championship boxing. Boxers from WSB and AIBA world championships. The information was recorded by ringside medical physicians. Stoppages per 10 000 rounds; stoppages per 1000 hours. Both studies show that the number of stoppages due to head blows was significantly decreased without head guards. The studies also showed that there was a notable increase in cuts. Removing head guards may reduce the already small risk of acute brain injury in amateur boxing.

  4. Remaining Relevant: Historical Contributions, Civil-Military Challenges, and Anti-Submarine Warfare Capabilities on Coast Guard Cutters

    DTIC Science & Technology

    2018-03-01

    HISTORICAL CONTRIBUTIONS, CIVIL-MILITARY CHALLENGES, AND ANTI-SUBMARINE WARFARE CAPABILITIES ON COAST GUARD CUTTERS by Brian A. Smicklas...CONTRIBUTIONS, CIVIL- MILITARY CHALLENGES, AND ANTI-SUBMARINE WARFARE CAPABILITIES ON COAST GUARD CUTTERS 5. FUNDING NUMBERS 6. AUTHOR(S) Brian A...MILITARY CHALLENGES, AND ANTI-SUBMARINE WARFARE CAPABILITIES ON COAST GUARD CUTTERS Brian A. Smicklas Commander, U.S. Coast Guard B.S., Coast

  5. Rapid Response in the Homeland

    DTIC Science & Technology

    2009-12-11

    SNG State National Guard USNG United States National Guard USNORTHCOM US Northern Command WMD Weapons of Mass Destruction WMD-CST Weapons of Mass...Guard exists simultaneously as two forces, the National Guard of the United States (USNG) and the state National Guard ( SNG ). The USNG is a reserve...9 military force composed of SNG militia members and is a joint reserve component of the United States Army and the United States Air Force. The

  6. Magnetic Guarding: Experimental and Numerical Results

    NASA Astrophysics Data System (ADS)

    Heinrich, Jonathon; Font, Gabriel; Garrett, Michael; Rose, D.; Genoni, T.; Welch, D.; McGuire, Thomas

    2017-10-01

    The magnetic field topology of Lockheed Martin's Compact Fusion Reactor (CFR) concept requires internal magnetic field coils. Internal coils for similar devices have leveraged levitating coils or coils with magnetically guarded supports. Magnetic guarding of supports has been investigated for multipole devices (theoretically and experimentally) without conclusive results. One outstanding question regarding magnetic guarding of supports is the magnitude and behavior of secondary plasma drifts resulting from magnetic guard fields (grad-B drifts, etc). We present magnetic-implicit PIC modeling results and preliminary proof of concept experimental results on magnetic guarding of internal-supports and the subsequent reduction in total plasma losses.

  7. Costs of mate-guarding in wild male long-tailed macaques (Macaca fascicularis): physiological stress and aggression.

    PubMed

    Girard-Buttoz, Cédric; Heistermann, Michael; Rahmi, Erdiansyah; Agil, Muhammad; Fauzan, Panji Ahmad; Engelhardt, Antje

    2014-09-01

    Mate-guarding is an important determinant of male reproductive success in a number of species. However, it is known to potentially incur costs. The aim of the present study was to assess the effect of mate-guarding on male physiological stress and aggression in long-tailed macaques, a species in which males mate-guard females to a lesser extent than predicted by the Priority of Access model (PoA). The study was carried out during two mating periods on three groups of wild long-tailed macaques in Indonesia by combining behavioral observations with non-invasive measurements of fecal glucocorticoid (fGC) levels. Mate-guarding was associated with a general rise in male stress hormone levels but, from a certain threshold of mate-guarding onwards, increased vigilance time was associated with a decrease in stress hormone output. Mate-guarding also increased male-male aggression rate and male vigilance time. Overall, alpha males were more physiologically stressed than other males independently of mating competition. Increased glucocorticoid levels during mate-guarding are most likely adaptive since it may help males to mobilize extra-energy required for mate-guarding and ultimately maintain a balanced energetic status. However, repeated exposure to high levels of stress over an extended period is potentially deleterious to the immune system and thus may carry costs. This potential physiological cost together with the cost of increased aggression mate-guarding male face may limit the male's ability to mate-guard females, explaining the deviance from the PoA model observed in long-tailed macaques. Comparing our results to previous findings we discuss how ecological factors, reproductive seasonality and rank achievement may modulate the extent to which costs of mate-guarding limit male monopolization abilities. Copyright © 2014. Published by Elsevier Inc.

  8. The Effectiveness of Shin Guards Used by Football Players

    PubMed Central

    Tatar, Yasar; Ramazanoglu, Nusret; Camliguney, Asiye Filiz; Saygi, Evrim Karadag; Cotuk, Hasan Birol

    2014-01-01

    In football, injuries from opponent contact occur commonly in the lower extremities. FIFA the world’s governing body for football requires players to wear shin guards. The aim of this study was to compare the protective effectiveness of polypropylene based shin guards with custom-made carbon fiber ones. Three commercial polypropylene shin guards (Adidas Predator™, Adidas UCL™, and Nike Mercurial™) and two custom-made carbon fiber shin guards were examined. The experimental setup had the following parts: 1) A pendulum attached a load cell at the tip (CAS Corp., Korea) and a fixed prosthetic foot equipped with a cleat to simulate an attacker’s foot. 2) An artificial tibia prepared by condensed foam and reinforced by carbon fibers protected with soft clothing. 3) A multifunctional sensor system (Tekscan Corp., F-Socket System, Turkey) to record the impact on the tibia. In the low impact force trials, only 2.79-9.63 % of the load was transmitted to the sensors. When comparing for mean force, peak force and impulse, both carbon fiber shin guards performed better than the commercial ones (Adidas Predator™, Adidas UCL™, and Nike Mercurial™) (p = 0.000). Based on these same parameters, the Nike Mercurial™ provided better protection than the Adidas Predator™ and the Adidas UCL™ (p = 0.000). In the high impact force trials, only 5.16-10.90 % of the load was transmitted to the sensors. For peak force and impulse, the carbon fiber shin guards provided better protection than all the others. Carbon fiber shin guards possess protective qualities superior to those of commercial polypropylene shin guards. Key Points Shin guards decrease the risk of serious injuries. Carbon shin guards provide sufficient protection against high impact forces. Commercially available Polypropylene based shin guards do not provide sufficient protection against high impact forces. PMID:24570615

  9. The effectiveness of shin guards used by football players.

    PubMed

    Tatar, Yasar; Ramazanoglu, Nusret; Camliguney, Asiye Filiz; Saygi, Evrim Karadag; Cotuk, Hasan Birol

    2014-01-01

    In football, injuries from opponent contact occur commonly in the lower extremities. FIFA the world's governing body for football requires players to wear shin guards. The aim of this study was to compare the protective effectiveness of polypropylene based shin guards with custom-made carbon fiber ones. Three commercial polypropylene shin guards (Adidas Predator™, Adidas UCL™, and Nike Mercurial™) and two custom-made carbon fiber shin guards were examined. The experimental setup had the following parts: 1) A pendulum attached a load cell at the tip (CAS Corp., Korea) and a fixed prosthetic foot equipped with a cleat to simulate an attacker's foot. 2) An artificial tibia prepared by condensed foam and reinforced by carbon fibers protected with soft clothing. 3) A multifunctional sensor system (Tekscan Corp., F-Socket System, Turkey) to record the impact on the tibia. In the low impact force trials, only 2.79-9.63 % of the load was transmitted to the sensors. When comparing for mean force, peak force and impulse, both carbon fiber shin guards performed better than the commercial ones (Adidas Predator™, Adidas UCL™, and Nike Mercurial™) (p = 0.000). Based on these same parameters, the Nike Mercurial™ provided better protection than the Adidas Predator™ and the Adidas UCL™ (p = 0.000). In the high impact force trials, only 5.16-10.90 % of the load was transmitted to the sensors. For peak force and impulse, the carbon fiber shin guards provided better protection than all the others. Carbon fiber shin guards possess protective qualities superior to those of commercial polypropylene shin guards. Key PointsShin guards decrease the risk of serious injuries.Carbon shin guards provide sufficient protection against high impact forces.Commercially available Polypropylene based shin guards do not provide sufficient protection against high impact forces.

  10. Effects of over-the-counter jaw-repositioning mouth guards on dynamic balance, flexibility, agility, strength, and power in college-aged male athletes.

    PubMed

    Golem, Devon L; Arent, Shawn M

    2015-02-01

    Improvements in muscular power and anaerobic performance have resulted from the use of jaw-repositioning mouth guards designed with advanced dental techniques. The high cost of such techniques has dissuaded the widespread use. Recently, more affordable, over-the-counter (OTC) jaw-repositioning mouth guards have become available. The primary objective of this study was to examine the effects of 2 OTC jaw-repositioning mouth guards on muscular power and strength performance in college-aged male athletes. It was hypothesized that similar to previous observations with advanced dentistry-designed mouth guards, OTC jaw-repositioning mouth guards would impart positive effects on muscular power but not have any effect on muscular strength. Secondary objectives of this study included the examination of the effects of 2 OTC jaw-repositioning mouth guards on other variables related to athletic performance. Male collegiate athletes (N = 20) participated in 4 separate testing sessions that consisted of assessment of muscular power, dynamic balance, flexibility, agility, and muscular strength. The 4 conditions, 1 per testing session, were assigned in a randomized order and consisted of a no-mouth guard control (CON), a placebo mouth guard, a self-adapted jaw-repositioning mouth guard (SA), and a custom-fitted jaw-repositioning mouth guard (CF). No significant differences were observed between conditions in muscular power (p = 0.78), dynamic balance (p = 0.99), agility (p = 0.22), or muscular strength (p = 0.47). The CF had significantly lower hip flexion than the CON (p = 0.014) and had significantly greater lumbar spine lateral flexion compared with the SA condition (p = 0.054). However, these flexibility differences lack practical relevance as the effect sizes remain very small (ES = -0.27 and -0.14, respectively). In conclusion, the jaw-repositioning technique used in the design of these OTC mouth guards did not affect performance. It is important to note that negative effects were not observed indicating that mouth guard use did not impede performance.

  11. 46 CFR 111.50-9 - Disconnecting and guarding.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Disconnecting and guarding. 111.50-9 Section 111.50-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-9 Disconnecting and guarding. Disconnecting and...

  12. 46 CFR 111.50-9 - Disconnecting and guarding.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Disconnecting and guarding. 111.50-9 Section 111.50-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-9 Disconnecting and guarding. Disconnecting and...

  13. 46 CFR 111.50-9 - Disconnecting and guarding.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Disconnecting and guarding. 111.50-9 Section 111.50-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-9 Disconnecting and guarding. Disconnecting and...

  14. 46 CFR 111.50-9 - Disconnecting and guarding.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Disconnecting and guarding. 111.50-9 Section 111.50-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-9 Disconnecting and guarding. Disconnecting and...

  15. Commandant Instructions 5354.6A: Administering the Coast Guard Recruiting Initiative for the Twenty-First Century (CGRIT) to the U.S. Coast Guard Academy

    DOT National Transportation Integrated Search

    1997-03-25

    Promulgates procedures to coordinate and administer the Coast Guard Recruiting : Initiative for the 21st century (CGRIT)program and prescribes application : procedures to the U.S. Coast Guard Academy.

  16. The Unmanned Initiative: A Strategic Appraisal of Coast Guard Unmanned Aerial Systems

    DTIC Science & Technology

    2011-06-01

    King also designated the Coast Guard as the service responsible for helicopter training, research and development. With no established training...Guard Deepwater Acquisition Programs,” Congressional Research Service (Washington, DC, Mar 30, 2010), 25. 15 U.S. Coast Guard, Land-Based UAS, 1-4...preproduction and research , the Coast Guard terminated its UAS program, citing “development risks and a lack of funding.”17 The lack of a cutter-based UAS

  17. Domestic and Expeditionary Readiness in the Twenty-First Century: Maintaining an Operationalized Army National Guard

    DTIC Science & Technology

    2012-12-06

    National Guard units mobilized to support Operation Desert Storm. Army National Guard units purchased commercial-off-the-shelf (COTS) communications ...the considerations for its future use are under critical scrutiny as America transitions into the first post -war period of the twenty-first century. A...specifically the Army National Guard, to an operational force may shape employment opportunities for the Army National Guard in a post -war environment.1 The

  18. Roles for National Guard Components: Current Thoughts and Future Possibilities

    DTIC Science & Technology

    2000-04-01

    Gen Russell C. Davis, chief, National Guard Bureau, remarks at the National Chamber of Commerce , Washington, D.C., June 1999. 5 Moskos and Burk, 176...Lt Gen Russell C. Davis, chief, National Guard Bureau, remarks at the National Chamber of Commerce , Washington, D.C., June 9 1999. 5 National Guard...National Guard Bureau, remarks to the National Chamber of Commerce , Washington, D.C., June 1999, n.p. On-line. Internet, 27 February 2000, available at

  19. 46 CFR 107.117 - Coast Guard addresses.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Coast Guard addresses. 107.117 Section 107.117 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.117 Coast Guard addresses. When approval of the Commandant is required under this...

  20. 46 CFR 107.117 - Coast Guard addresses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Coast Guard addresses. 107.117 Section 107.117 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.117 Coast Guard addresses. When approval of the Commandant is required under this...

  1. 46 CFR 107.117 - Coast Guard addresses.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Coast Guard addresses. 107.117 Section 107.117 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.117 Coast Guard addresses. When approval of the Commandant is required under this...

  2. 46 CFR 107.117 - Coast Guard addresses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Coast Guard addresses. 107.117 Section 107.117 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.117 Coast Guard addresses. When approval of the Commandant is required under this...

  3. 46 CFR 107.117 - Coast Guard addresses.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Coast Guard addresses. 107.117 Section 107.117 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION General § 107.117 Coast Guard addresses. When approval of the Commandant is required under this...

  4. 46 CFR 188.10-13 - Coast Guard District Commander.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Coast Guard District Commander. 188.10-13 Section 188.10-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-13 Coast Guard District Commander...

  5. 46 CFR 188.10-13 - Coast Guard District Commander.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Coast Guard District Commander. 188.10-13 Section 188.10-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-13 Coast Guard District Commander...

  6. 46 CFR 188.10-13 - Coast Guard District Commander.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Coast Guard District Commander. 188.10-13 Section 188.10-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-13 Coast Guard District Commander...

  7. 46 CFR 188.10-13 - Coast Guard District Commander.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Coast Guard District Commander. 188.10-13 Section 188.10-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-13 Coast Guard District Commander...

  8. 46 CFR 188.10-13 - Coast Guard District Commander.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Coast Guard District Commander. 188.10-13 Section 188.10-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 188.10-13 Coast Guard District Commander...

  9. 33 CFR 100.10 - Coast Guard-State agreements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Coast Guard-State agreements. 100.10 Section 100.10 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.10 Coast Guard-State agreements. (a...

  10. 33 CFR 100.10 - Coast Guard-State agreements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Coast Guard-State agreements. 100.10 Section 100.10 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.10 Coast Guard-State agreements. (a...

  11. 1. AERIAL VIEW TO WEST OF COAST GUARD AIR STATION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. AERIAL VIEW TO WEST OF COAST GUARD AIR STATION SAN FRANCISCO, SHOWING ALL MAJOR BUILDINGS. 8X10 black and white silver gelatin print. United States Coast Guard, February 1962. - U.S. Coast Guard Air Station San Francisco, 1020 North Access Road, San Francisco, San Francisco County, CA

  12. 2. AERIAL VIEW TO SOUTHEAST OF COAST GUARD AIR STATION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. AERIAL VIEW TO SOUTHEAST OF COAST GUARD AIR STATION SAN FRANCISCO, SHOWING ALL MAJOR BUILDINGS. 8X10 black and white silver gelatin print. United States Coast Guard, February 1962. - U.S. Coast Guard Air Station San Francisco, 1020 North Access Road, San Francisco, San Francisco County, CA

  13. Coast guard : as deepwater systems integrator, coast guard Is reassessing costs and capabilities but lags in applying its disciplined acquisition approach.

    DOT National Transportation Integrated Search

    2009-07-01

    The Deepwater Program includes efforts to build or modernize ships and aircraft and to procure other capabilities. In 2002, the Coast Guard contracted with Integrated Coast Guard Systems (ICGS) to manage the acquisition as systems integrator. After a...

  14. 46 CFR 108.223 - Guards on exposed equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... have hand covers, guards, or rails installed on all belts, gears, shafts, pulleys, sprockets, spindles... 46 Shipping 4 2010-10-01 2010-10-01 false Guards on exposed equipment. 108.223 Section 108.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN...

  15. U.S. Coast Guard cutter personnel on Sweetbriar train their fire ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    U.S. Coast Guard cutter personnel on Sweetbriar train their fire hoses on a burning pleasure boat in an Alaskan harbor. A U.S. Coast Guard rigid-hull inflatable helps with the fire-fighting effort - U.S. Coast Guard Cutter SWEETBRIER, Cordova, Valdez-Cordova Census Area, AK

  16. 50. Elevation view underway, showing "new" coast guard paint scheme ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. Elevation view underway, showing "new" coast guard paint scheme and A-frame crane. Note crews quarters expanded over turtle deck at stern. - U.S. Coast Guard Cutter WHITE SUMAC, U.S. Coast Guard 8th District Base, 4640 Urquhart Street, New Orleans, Orleans Parish, LA

  17. 46 CFR 111.50-9 - Disconnecting and guarding.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Disconnecting and guarding. 111.50-9 Section 111.50-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS... guarding of overcurrent protective devices must meet Part IV of Article 240 of NFPA NEC 2002 (incorporated...

  18. Effect of a grounded object on radon measurement using AlphaGUARD.

    PubMed

    Ichitsubo, Hirokazu; Yamada, Yuji

    2004-07-01

    ABSTRACT-: The effects on radon concentration measurement of a grounded object near the opening of a cylindrical ionization chamber were studied using AlphaGUARD. AlphaGUARD comes with a flow measurement adapter that fits on the front of the AlphaGUARD ionization chamber. If the adapter nozzle is grounded, the radon concentration is falsely measured at 0 Bq m. A metal connector for use between the AlphaGUARD and the air duct wall was manufactured in our laboratory. When the connector is grounded, the radon concentration is again falsely measured as 0 Bq m. If the nozzle or connector is ungrounded, the AlphaGUARD measures radon concentration accurately. Health Phys.

  19. 30 CFR 75.827 - Guarding of trailing cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guarding of trailing cables. 75.827 Section 75.827 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND...-Voltage Longwalls § 75.827 Guarding of trailing cables. (a) Guarding. (1) The high-voltage cable must be...

  20. 33 CFR 165.1339 - Safety Zone; Coast Guard Exercise Area, Hood Canal, Washington.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Safety Zone; Coast Guard Exercise... § 165.1339 Safety Zone; Coast Guard Exercise Area, Hood Canal, Washington. (a) Location. The following... Coast Guard training exercise while such vessel is transiting Hood Canal, WA between Foul Weather Bluff...

  1. 33 CFR 165.1339 - Safety Zone; Coast Guard Exercise Area, Hood Canal, Washington.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Safety Zone; Coast Guard Exercise... § 165.1339 Safety Zone; Coast Guard Exercise Area, Hood Canal, Washington. (a) Location. The following... Coast Guard training exercise while such vessel is transiting Hood Canal, WA between Foul Weather Bluff...

  2. sexual assault « Coast Guard All Hands

    Science.gov Websites

    accountability Some potentially positive news from the Sexual Assault Prevention and Response (SAPR) program: The . Coast Guard Sexual Assault Prevention and Response program logo. U.S. Coast Guard illustration by Petty Sexual Assault Prevention and Response Office, and U.S. Coast Guard Rear Adm. Erica Schwartz, director of

  3. 30 CFR 56.12066 - Guarding trolley wires and bare powerlines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guarding trolley wires and bare powerlines. 56... Electricity § 56.12066 Guarding trolley wires and bare powerlines. Where metallic tools or equipment can come in contact with trolley wires or bare powerlines, the lines shall be guarded or deenergized. ...

  4. 30 CFR 56.12066 - Guarding trolley wires and bare powerlines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Guarding trolley wires and bare powerlines. 56... Electricity § 56.12066 Guarding trolley wires and bare powerlines. Where metallic tools or equipment can come in contact with trolley wires or bare powerlines, the lines shall be guarded or deenergized. ...

  5. 30 CFR 57.12066 - Guarding trolley wires and bare powerlines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Guarding trolley wires and bare powerlines. 57... MINES Electricity Surface Only § 57.12066 Guarding trolley wires and bare powerlines. Where metallic tools or equipment can come in contact with trolley wires or bare powerlines, the lines shall be guarded...

  6. 30 CFR 57.12066 - Guarding trolley wires and bare powerlines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guarding trolley wires and bare powerlines. 57... MINES Electricity Surface Only § 57.12066 Guarding trolley wires and bare powerlines. Where metallic tools or equipment can come in contact with trolley wires or bare powerlines, the lines shall be guarded...

  7. 46 CFR 50.10-5 - Coast Guard District Commander or District Commander.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Coast Guard District Commander or District Commander. 50.10-5 Section 50.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 50.10-5 Coast Guard District...

  8. 77 FR 26699 - Safety Zone; Coast Guard Exercise, Hood Canal, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... would be impracticable to delay this important exercise to allow for a delayed effective date...-AA00 Safety Zone; Coast Guard Exercise, Hood Canal, WA AGENCY: Coast Guard, DHS. ACTION: Temporary... a Coast Guard Ready for Operations exercise in Hood Canal, WA that will take place between May 08...

  9. A comparative study of the Arabidopsis thaliana guard-cell transcriptome and its modulation by sucrose

    USDA-ARS?s Scientific Manuscript database

    To test the hypothesis that photosynthesis-derived sugar signals guard cells to adjust stomatal opening, we determined the profile of genes expressed in isolated guard cells. The results revealed that expression of 289 genes increased in guard cells in response to sucrose. Consistent with the hypoth...

  10. 33 CFR 173.35 - Coast Guard validation sticker.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Coast Guard validation sticker... Guard validation sticker. No person may use a vessel except a vessel exempted in § 173.13 that has a number issued by the Coast Guard unless it has the validation sticker issued with the certificate of...

  11. 33 CFR 173.35 - Coast Guard validation sticker.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Coast Guard validation sticker... Guard validation sticker. No person may operate a vessel except a vessel exempted in § 173.13 that has a number issued by the Coast Guard unless it has the validation sticker issued with the certificate of...

  12. 33 CFR 173.35 - Coast Guard validation sticker.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Coast Guard validation sticker... Guard validation sticker. No person may use a vessel except a vessel exempted in § 173.13 that has a number issued by the Coast Guard unless it has the validation sticker issued with the certificate of...

  13. 33 CFR 173.35 - Coast Guard validation sticker.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Coast Guard validation sticker... Guard validation sticker. No person may operate a vessel except a vessel exempted in § 173.13 that has a number issued by the Coast Guard unless it has the validation sticker issued with the certificate of...

  14. 33 CFR 173.35 - Coast Guard validation sticker.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Coast Guard validation sticker... Guard validation sticker. No person may operate a vessel except a vessel exempted in § 173.13 that has a number issued by the Coast Guard unless it has the validation sticker issued with the certificate of...

  15. 78 FR 32219 - Safety Zone, Temporary Change for Recurring Fifth Coast Guard District Fireworks Displays, Middle...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-29

    ... 1625-AA00 Safety Zone, Temporary Change for Recurring Fifth Coast Guard District Fireworks Displays, Middle River; Baltimore County, MD AGENCY: Coast Guard, DHS. ACTION: Notice of Proposed Rulemaking. SUMMARY: The Coast Guard is proposing a temporary change to the enforcement periods and regulated areas of...

  16. Resistance to mate guarding scale in women: psychometric properties.

    PubMed

    Cousins, Alita J; Fugère, Madeleine A; Riggs, Matthew L

    2015-02-03

    One individual's actions may affect the evolutionary fitness of another individual. Sexually antagonistic coevolution occurs when one partner's behavior decreases the fitness of the other partner (Rice, 1996). This conflict pressures the other partner to counter these disadvantageous actions. Mate guarding is a mate retention tactic aimed at keeping a partner from cheating. Mate guarding may reduce mate choice, especially for extra pair mates. Therefore, some individuals may resist their partner's mate guarding tactics. We developed a scale to measure resistance to mate guarding and tested it in women (N = 1069). Using exploratory factor analysis (EFA), six theoretically sound factors emerged and explained 69% of the variance. Confirmatory Factor Analysis showed strong support for the six original subscales as well as for the overall scale. The subscales had high reliability. The validity of the Resistance to Mate Guarding Scale was also excellent. Women who stated they used more resistance to mate guarding strategies also indicated that they had partners who mate guarded more, were less invested in their relationships, felt their partners were more controlling, had a more avoidant attachment style, and had a more unrestricted sociosexual orientation.

  17. 46 CFR 32.02-15 - Guards at dangerous places-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Guards at dangerous places-TB/ALL. 32.02-15 Section 32..., AND HULL REQUIREMENTS Safety Requirements § 32.02-15 Guards at dangerous places—TB/ALL. All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or...

  18. 46 CFR 32.02-15 - Guards at dangerous places-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Guards at dangerous places-TB/ALL. 32.02-15 Section 32..., AND HULL REQUIREMENTS Safety Requirements § 32.02-15 Guards at dangerous places—TB/ALL. All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or...

  19. 46 CFR 32.02-15 - Guards at dangerous places-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Guards at dangerous places-TB/ALL. 32.02-15 Section 32..., AND HULL REQUIREMENTS Safety Requirements § 32.02-15 Guards at dangerous places—TB/ALL. All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or...

  20. 46 CFR 32.02-15 - Guards at dangerous places-TB/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Guards at dangerous places-TB/ALL. 32.02-15 Section 32..., AND HULL REQUIREMENTS Safety Requirements § 32.02-15 Guards at dangerous places—TB/ALL. All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or...

  1. 5 CFR 531.216 - Setting pay when an employee moves from a Department of Defense or Coast Guard nonappropriated...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Department of Defense or Coast Guard nonappropriated fund instrumentality. 531.216 Section 531.216... employee moves from a Department of Defense or Coast Guard nonappropriated fund instrumentality. (a... Department of Defense or the Coast Guard from a position in a nonappropriated fund instrumentality (NAFI) (as...

  2. 5 CFR 531.216 - Setting pay when an employee moves from a Department of Defense or Coast Guard nonappropriated...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Department of Defense or Coast Guard nonappropriated fund instrumentality. 531.216 Section 531.216... employee moves from a Department of Defense or Coast Guard nonappropriated fund instrumentality. (a... Department of Defense or the Coast Guard from a position in a nonappropriated fund instrumentality (NAFI) (as...

  3. 5 CFR 531.216 - Setting pay when an employee moves from a Department of Defense or Coast Guard nonappropriated...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Department of Defense or Coast Guard nonappropriated fund instrumentality. 531.216 Section 531.216... employee moves from a Department of Defense or Coast Guard nonappropriated fund instrumentality. (a... Department of Defense or the Coast Guard from a position in a nonappropriated fund instrumentality (NAFI) (as...

  4. 5 CFR 531.216 - Setting pay when an employee moves from a Department of Defense or Coast Guard nonappropriated...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Department of Defense or Coast Guard nonappropriated fund instrumentality. 531.216 Section 531.216... employee moves from a Department of Defense or Coast Guard nonappropriated fund instrumentality. (a... Department of Defense or the Coast Guard from a position in a nonappropriated fund instrumentality (NAFI) (as...

  5. 5 CFR 531.216 - Setting pay when an employee moves from a Department of Defense or Coast Guard nonappropriated...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Department of Defense or Coast Guard nonappropriated fund instrumentality. 531.216 Section 531.216... employee moves from a Department of Defense or Coast Guard nonappropriated fund instrumentality. (a... Department of Defense or the Coast Guard from a position in a nonappropriated fund instrumentality (NAFI) (as...

  6. 33 CFR 165.152 - Coast Guard Station Fire Island, Long Island, New York-safety zone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Coast Guard Station Fire Island, Long Island, New York-safety zone. 165.152 Section 165.152 Navigation and Navigable Waters COAST GUARD... § 165.152 Coast Guard Station Fire Island, Long Island, New York—safety zone. (a) Location. The...

  7. 32 CFR 728.25 - Army and Air Force National Guard personnel.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 5 2013-07-01 2013-07-01 false Army and Air Force National Guard personnel. 728... Guard Personnel § 728.25 Army and Air Force National Guard personnel. (a) Medical and dental care. Upon... Care) and AFR 168-6 (Persons Authorized Medical Care) to members of the Army and Air Force National...

  8. 32 CFR 728.25 - Army and Air Force National Guard personnel.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 5 2012-07-01 2012-07-01 false Army and Air Force National Guard personnel. 728... Guard Personnel § 728.25 Army and Air Force National Guard personnel. (a) Medical and dental care. Upon... Care) and AFR 168-6 (Persons Authorized Medical Care) to members of the Army and Air Force National...

  9. 32 CFR 728.25 - Army and Air Force National Guard personnel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Army and Air Force National Guard personnel. 728... Guard Personnel § 728.25 Army and Air Force National Guard personnel. (a) Medical and dental care. Upon... Care) and AFR 168-6 (Persons Authorized Medical Care) to members of the Army and Air Force National...

  10. 32 CFR 728.25 - Army and Air Force National Guard personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 5 2011-07-01 2011-07-01 false Army and Air Force National Guard personnel. 728... Guard Personnel § 728.25 Army and Air Force National Guard personnel. (a) Medical and dental care. Upon... Care) and AFR 168-6 (Persons Authorized Medical Care) to members of the Army and Air Force National...

  11. 75 FR 53195 - Security Zone; U.S. Coast Guard BSU Seattle, Pier 36, Seattle, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-31

    ... its effects on them and participate in the rulemaking process. Small businesses may send comments on... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2010-0021] RIN 1625-AA87 Security Zone; U.S. Coast Guard BSU Seattle, Pier 36, Seattle, WA AGENCY: Coast Guard, DHS. ACTION...

  12. 33 CFR 100.906 - Grand Haven Coast Guard Festival Waterski Show, Grand Haven, MI.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Grand Haven Coast Guard Festival Waterski Show, Grand Haven, MI. 100.906 Section 100.906 Navigation and Navigable Waters COAST GUARD... Grand Haven Coast Guard Festival Waterski Show, Grand Haven, MI. (a) Regulated Area. All waters of the...

  13. 78 FR 9709 - Draft Guidance Regarding Voluntary Inspection of Vessels for Compliance With the Maritime Labour...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-11

    ... availability of a draft Navigation and Vessel Inspection Circular (NVIC) that sets forth the Coast Guard's... guidance to the maritime industry, Coast Guard marine inspectors, and other affected parties on how the... and Coast Guard marine inspectors on how the Coast Guard intends to implement this new voluntary...

  14. 4. AERIAL VIEW TO SOUTHEAST OF ENTIRE COAST GUARD AIR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. AERIAL VIEW TO SOUTHEAST OF ENTIRE COAST GUARD AIR STATION SAN FRANCISCO. 8X10 black and white silver gelatin print. United States Coast Guard Official Photograph, 12th District, File No. 62751-22 A.S. Date unknown. - U.S. Coast Guard Air Station San Francisco, 1020 North Access Road, San Francisco, San Francisco County, CA

  15. 77 FR 59083 - Safety Zone; Coast Guard Exercise, Hood Canal, Washington

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-26

    ... 1625-AA00 Safety Zone; Coast Guard Exercise, Hood Canal, Washington AGENCY: Coast Guard, DHS. ACTION... involved in a Coast Guard Ready for Operations exercise in Hood Canal, WA that will take place between Oct... during the exercise and will do so by prohibiting any person or vessel from entering or remaining in the...

  16. 20 CFR 1002.306 - Is a National Guard civilian technician considered a State or Federal employee for purposes of...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Is a National Guard civilian technician... a National Guard civilian technician considered a State or Federal employee for purposes of USERRA? A National Guard civilian technician is considered a State employee for USERRA purposes, although he...

  17. 5 CFR 831.306 - Service as a National Guard technician before January 1, 1969.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Service as a National Guard technician... National Guard technician before January 1, 1969. (a) Definitions. In this section—(1) Service as a National Guard technician is service performed under section 709 of title 32, United States Code (or under...

  18. Collector/collector guard ring balancing circuit eliminates edge effects

    NASA Technical Reports Server (NTRS)

    Lieb, D. P.

    1966-01-01

    Circuit in which an emitter is maintained opposite a concentric collector and guard structure is achieved by matching the temperature and potential of the guard with that of the collector over the operating range. This control system is capable of handling up to 100 amperes in the guard circuit and 200 amperes in the collectors circuit.

  19. Freedom of Information Act (FOIA) - The National Guard

    Science.gov Websites

    from the public for records created under the seal of the Chief, National Guard Bureau as authorized by for records created by the Chief, National Guard Bureau's Joint Staff, Personal Staff, and Special FOIA Request for National Guard Bureau (NGB) Records NGB FOIA Office (NGB/JA-OIP) 111 South George

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reckmann, U.; Scheibe, R.; Raschke, K.

    We investigated whether the reductive pentose phosphate path in guard cells of Pisum sativum had the capacity to contribute significantly to the production of osmotica during stomatal opening in the light. Amounts of ribulose 1,5-bisphophate carboxylase/oxygenase (Rubisco) were determined by the ({sup 14}C) carboxyarabinitol bisphosphate assay. A guard cell contained about 1.2 and a mesophyll cell about 324 picograms of the enzyme; the ratio was 1:270. The specific activities of Rubisco in guard cells and in mesophyll cells were equal; there was no indication of a specific inhibitor of Rubisco in guard cells. Rubisco activity was 115 femtomol per guard-cellmore » protoplast and hour. This value was different from zero with a probability of 0.99. After exposure of guard-cell protoplasts to {sup 14}CO{sub 2} for 2 seconds in the light, about one-half of the radioactivity was in phosphorylated compounds and <10% in malate. Guard cells in epidermal strips produced a different labelling pattern; in the light, <10% of the label was in phosphorylated compounds and about 60% in malate. The rate of solute accumulation in intact guard cells was estimated to have been 900 femto-osmol per cell and hour. If Rubisco operated at full capacity in guard cells, and hexoses were produced as osmotica, solutes could be supplied at a rate of 19femto-osmol per cell and hour, which would constitute 2% of the estimated requirement. The capacity of guard-cell Rubisco to meet the solute requirement for stomatal opening in leaves of Pisum sativum is insignificant.« less

  1. The Solanum tuberosum KST1 partial promoter as a tool for guard cell expression in multiple plant species.

    PubMed

    Kelly, Gilor; Lugassi, Nitsan; Belausov, Eduard; Wolf, Dalia; Khamaisi, Belal; Brandsma, Danja; Kottapalli, Jayaram; Fidel, Lena; Ben-Zvi, Batsheva; Egbaria, Aiman; Acheampong, Atiako Kwame; Zheng, Chuanlin; Or, Etti; Distelfeld, Assaf; David-Schwartz, Rakefet; Carmi, Nir; Granot, David

    2017-05-17

    To date, guard cell promoters have been examined in only a few species, primarily annual dicots. A partial segment of the potato (Solanum tuberosum) KST1 promoter (KST1 partial promoter, KST1ppro) has previously been shown to confer guard cell expression in potato, tomato (Solanum lycopersicum), citrus [Troyer citrange (C. sinensis×Poncirus trifoliata)], and Arabidopsis (Arabidopsis thaliana). Here, we describe an extensive analysis of the expression pattern of KST1ppro in eight (previously reported, as well as new) species from five different angiosperm families, including the Solanaceae and the Cucurbitaceae, Arabidopsis, the monocot barley (Hordeum vulgare), and two perennial species: grapevine (Vitis vinifera) and citrus. Using confocal imaging and three-dimensional movies, we demonstrate that KST1ppro drives guard cell expression in all of these species, making it the first dicot-originated guard cell promoter shown to be active in a monocot and the first promoter reported to confer guard cell expression in barley and cucumber (Cucumis sativus). The results presented here indicate that KST1ppro can be used to drive constitutive guard cell expression in monocots and dicots and in both annual and perennial plants. In addition, we show that the KST1ppro is active in guard cells shortly after the symmetric division of the guard mother cell and generates stable expression in mature guard cells. This allows us to follow the spatial and temporal distribution of stomata in cotyledons and true leaves. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  2. Oryza sativa H+-ATPase (OSA) is Involved in the Regulation of Dumbbell-Shaped Guard Cells of Rice.

    PubMed

    Toda, Yosuke; Wang, Yin; Takahashi, Akira; Kawai, Yuya; Tada, Yasuomi; Yamaji, Naoki; Feng Ma, Jian; Ashikari, Motoyuki; Kinoshita, Toshinori

    2016-06-01

    The stomatal apparatus consists of a pair of guard cells and regulates gas exchange between the leaf and atmosphere. In guard cells, blue light (BL) activates H(+)-ATPase in the plasma membrane through the phosphorylation of its penultimate threonine, mediating stomatal opening. Although this regulation is thought to be widely adopted among kidney-shaped guard cells in dicots, the molecular basis underlying that of dumbbell-shaped guard cells in monocots remains unclear. Here, we show that H(+)-ATPases are involved in the regulation of dumbbell-shaped guard cells. Stomatal opening of rice was promoted by the H(+)-ATPase activator fusicoccin and by BL, and the latter was suppressed by the H(+)-ATPase inhibitor vanadate. Using H(+)-ATPase antibodies, we showed the presence of phosphoregulation of the penultimate threonine in Oryza sativa H(+)-ATPases (OSAs) and localization of OSAs in the plasma membrane of guard cells. Interestingly, we identified one H(+)-ATPase isoform, OSA7, that is preferentially expressed among the OSA genes in guard cells, and found that loss of function of OSA7 resulted in partial insensitivity to BL. We conclude that H(+)-ATPase is involved in BL-induced stomatal opening of dumbbell-shaped guard cells in monocotyledon species. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists.

  3. 33 CFR 165.776 - Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico 165.776 Section 165.776 Navigation and Navigable Waters COAST... Guard District § 165.776 Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico (a...

  4. 33 CFR 165.776 - Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico 165.776 Section 165.776 Navigation and Navigable Waters COAST... Guard District § 165.776 Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico (a...

  5. 33 CFR 165.776 - Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico. 165.776 Section 165.776 Navigation and Navigable Waters COAST... Guard District § 165.776 Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico. (a...

  6. 33 CFR 165.776 - Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico. 165.776 Section 165.776 Navigation and Navigable Waters COAST... Guard District § 165.776 Security Zone; Coast Guard Base San Juan, San Juan Harbor, Puerto Rico. (a...

  7. Integrated Unit Deployments: Rethinking Air National Guard Fighter Mobilizations

    DTIC Science & Technology

    2016-06-01

    INTEGRATED UNIT DEPLOYMENTS: RETHINKING AIR NATIONAL GUARD FIGHTER MOBILIZATIONS BY MAJOR ANDREW P. JACOB A THESIS...This study comprises an analysis of the mobilization and deployment of Air National Guard fighter aircraft units in a search for an efficient and... mobilization . This thesis suggests that Integrated Unit Deployments will provide the balance between Air National Guard overseas deployments and

  8. 33 CFR 165.168 - Safety Zones; Coast Guard Captain of the Port New York Fireworks Displays.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Safety Zones; Coast Guard Captain... Guard District § 165.168 Safety Zones; Coast Guard Captain of the Port New York Fireworks Displays. (a) New York Harbor. The following areas are safety zones: (1) Liberty Island Safety Zone: All waters of...

  9. 77 FR 47519 - Annual Marine Events in the Eighth Coast Guard District, Sabine River; Orange, TX

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-09

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 100 [Docket No. USCG-2012-0656] Annual Marine Events in the Eighth Coast Guard District, Sabine River; Orange, TX AGENCY: Coast Guard, DHS... Regulations for the S.P.O.R.T. Power Boat Neches River in Orange, TX from 3 p.m. on September 21, 2012...

  10. 29 CFR 1915.73 - Guarding of deck openings and edges.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Guarding of deck openings and edges. 1915.73 Section 1915..., Ladders and Other Working Surfaces § 1915.73 Guarding of deck openings and edges. (a) The provisions of... coamings to a height of 24 inches or around other large openings, the edge of the opening shall be guarded...

  11. Rethinking Guard Cell Metabolism1[OPEN

    PubMed Central

    2016-01-01

    Stomata control gaseous fluxes between the internal leaf air spaces and the external atmosphere and, therefore, play a pivotal role in regulating CO2 uptake for photosynthesis as well as water loss through transpiration. Guard cells, which flank the stomata, undergo adjustments in volume, resulting in changes in pore aperture. Stomatal opening is mediated by the complex regulation of ion transport and solute biosynthesis. Ion transport is exceptionally well understood, whereas our knowledge of guard cell metabolism remains limited, despite several decades of research. In this review, we evaluate the current literature on metabolism in guard cells, particularly the roles of starch, sucrose, and malate. We explore the possible origins of sucrose, including guard cell photosynthesis, and discuss new evidence that points to multiple processes and plasticity in guard cell metabolism that enable these cells to function effectively to maintain optimal stomatal aperture. We also discuss the new tools, techniques, and approaches available for further exploring and potentially manipulating guard cell metabolism to improve plant water use and productivity. PMID:27609861

  12. Male songbirds provide indirect parental care by guarding females during incubation

    USGS Publications Warehouse

    Fedy, B.C.; Martin, T.E.

    2009-01-01

    Across many taxa, guarding of fertile mates is a widespread tactic that enhances paternity assurance. However, guarding of mates can also occur during the nonfertile period, and the fitness benefits of this behavior are unclear. Male songbirds, for example, sometimes guard nonfertile females during foraging recesses from incubation. We hypothesized that guarding postreproductive mates may have important, but unrecognized, benefits by enhancing female foraging efficiency, thereby increasing time spent incubating eggs. We tested the hypothesis in 2 songbird species by examining female behavior during natural and experimentally induced absences of males. Male absence caused increased vigilance in foraging females that decreased their efficiency and resulted in less time spent incubating eggs. Male guarding of nonfertile females can thus provide a previously unrecognized form of indirect parental care.

  13. Unilateral or "side-locked" migrainous headache with autonomic symptoms linked to night guard use.

    PubMed

    Strahlendorf, Jean; Schiffer, Randolph; Strahlendorf, Howard

    2008-01-01

    Night guards are commonly prescribed as a palliative measure for bruxism, temporomandibular joint symptoms, and associated disorders. We describe a patient with a 10- to 12-year history of night guard use with concurrent unilateral side-locked migrainous headaches with autonomic symptoms characteristic of trigeminal autonomic cephalgia. These headaches were refractory to numerous pharmacological interventions. Upon self-initiated cessation of night guard use, there was complete remission of headaches. We believe the headaches were initiated by night guard-initiated irritation of the trigeminal nerve and a trigeminal autonomic reflex resulting in unilateral migrainous headache with autonomic signs.

  14. 30 CFR 75.816 - Guarding of cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.816 Guarding of cables. (a) High-voltage cables must be guarded at the following locations...

  15. Environmental Activities of the U.S. Coast Guard

    DTIC Science & Technology

    2010-12-06

    scientific efforts of other groups. The Coast Guard operates three icebreakers in the Arctic and Antarctic , and provides supplies to remote stations...and Atmospheric Administration (NOAA). The Coast Guard operates three icebreakers in the Arctic and Antarctic , and provides supplies to remote...stations.17 The Coast Guard also participates in the International Ice Patrol, which monitors iceberg danger in the northwest Atlantic, particularly in the

  16. Photocopy of plan (in collection of U.S. Coast Guard Civil ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of plan (in collection of U.S. Coast Guard Civil Engineering Unit Providence, Warwick, RI), U.S. Coast Guard Civil Engineering, third district, marine railway, Sandy Hook Station, Ft. Hancock, Sandy Hook, NJ, repairs, plan sections & framing details, wharf B - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  17. Photocopy of plan (in collection of U.S. Coast Guard Civil ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of plan (in collection of U.S. Coast Guard Civil Engineering Unit Providence, Warwick, RI), U.S. Coast Guard Civil Engineering, third district, Sandy Hook L/B Station showing boat basin plan, circa 1945 Detail of western docking structure - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  18. Credit BG. View looking north northeast at Guard House and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. View looking north northeast at Guard House and entrance to Building 4505 complex. This Guard House was built in 1993 as a portable unit; it replaced an older structure. The Building 4505 complex is surrounded by a security fence. Building 4496 appears to immediate right of view - Edwards Air Force Base, North Base, Guard House, Northeast of A Street, Boron, Kern County, CA

  19. Pasdaran Incorporated: Evolving from Revolutionary to Praetorian Guard

    DTIC Science & Technology

    2010-03-01

    IRGN - Islamic Revolutionary Guards Corps’ Navy IRGQF - Islamic Revolutionary Guards Corps’ Qods Force IRI - Islamic Republic of Iran IRIAF - Islamic...1 I. INTRODUCTION A. PURPOSE The Islamic Revolutionary Guards Corps1 (IRGC) of the Islamic Republic of Iran ( IRI ) is a unique establishment that...civil–military relations. Until recently, conventional wisdom saw the IRGC as just a paramilitary element of the IRI national-security system. It

  20. Maritime Homeland Command Control: Teaching an Old Dog New Tricks

    DTIC Science & Technology

    2002-02-04

    Security, Command and Control, Navy, Coast Guard, Customs Service, Centralized Control, Decentralized Execution, Organization by Objectives 15.Abstract...primarily responsible for the maritime homeland, the Navy, the Coast guard, the Customs Service, should provide resources and command capabilities to a...Coast Guard, the Customs Service, should provide resources and command capabilities to a unified command and control structure. Coast Guard forces and

  1. Evaluation of US rear underride guard regulation for large trucks using real-world crashes.

    PubMed

    Brumbelow, Matthew L; Blanar, Laura

    2010-11-01

    Current requirements for rear underride guards on large trucks are set by the National Highway Traffic Safety Administration in Federal Motor Vehicle Safety Standards (FMVSS) 223 and 224. The standards have been in place since 1998, but their adequacy has not been evaluated apart from two series of controlled crash tests. The current study used detailed reviews of real-world crashes from the Large Truck Crash Causation Study to assess the ability of guards that comply with certain aspects of the regulation to mitigate passenger vehicle underride. It also evaluated the dangers posed by underride of large trucks that are exempt from guard requirements. For the 115 cases meeting the inclusion criteria, coded data, case narratives, photographs, and measurements were used to examine the interaction between study vehicles. The presence and type of underride guard was determined, and its performance in mitigating underride was categorized. Overall, almost one-half of the passenger vehicles had underride damage classified as severe or catastrophic. These vehicles accounted for 23 of the 28 in which occupants were killed. For the cases involving trailers with underride guards compliant with one or both FMVSS, guard deformation or complete failure was frequent and most commonly due to weak attachments, buckling of the trailer chassis, or bending of the lateral end of the guard under narrow overlap loading. Most of the truck units studied qualified for at least one of the FMVSS exemptions. The two largest groups were trailers with small wheel setbacks and single-unit straight trucks. Dump trucks represented a particularly hazardous category of straight truck. The current study suggests several weaknesses in the rear underride guard regulation. The standard allows too much ground clearance, the quasi-static test conditions allow guard designs that fail in narrow overlap crashes, and certifying guards independent of trailers leads to systems with inadequate attachment and chassis strength. Additionally, the regulation should be expanded to cover a higher percentage of the large truck fleet.

  2. Directory - Social Media - The National Guard

    Science.gov Websites

    Delta Company, 2-151 Infantry Regiment 384th Military Police Company Indiana Officer Candidate School City, TN Tennessee National Guard Company Grade Officers RSP Delta Twitter Tennessee National Guard

  3. Features - The National Guard

    Science.gov Websites

    Suicide Prevention Vigilant Guard Winter Olympics 2009 373rd Birthday H1N1 Flu Awareness Haiti Earthquake Army Suicide Prevention Month Warrior Care Midwest Flooding National Level Exercise National Guard's

  4. Guard cell photosynthesis is critical for stomatal turgor production, yet does not directly mediate CO2- and ABA-induced stomatal closing

    PubMed Central

    Azoulay-Shemer, Tamar; Palomares, Axxell; Bagheri, Andish; Israelsson-Nordstrom, Maria; Engineer, Cawas B.; Bargmann, Bastiaan O.R.; Stephan, Aaron B.; Schroeder, Julian I.

    2015-01-01

    SUMMARY Stomata mediate gas exchange between the inter-cellular spaces of leaves and the atmosphere. CO2 levels in leaves (Ci) are determined by respiration, photosynthesis, stomatal conductance and atmospheric [CO2]. [CO2] in leaves mediates stomatal movements. The role of guard-cell photosynthesis in stomatal conductance responses is a matter of debate, and genetic approaches are needed. We have generated transgenic Arabidopsis plants that are chlorophyll-deficient in guard cells only, expressing a constitutively active chlorophyllase in a guard-cell specific enhancer trap-line. Our data show that more than 90% of guard cells were chlorophyll-deficient. Interestingly, approximately ~ 45% of stomata had an unusual, previously not-described, morphology of thin-shaped chlorophyll-less stomata. Nevertheless, stomatal size, stomatal index, plant morphology, and whole-leaf photosynthetic parameters (PSII, qP, qN, FV′/FM′) were comparable to wild-type plants. Time-resolved intact leaf gas exchange analyses showed a reduction in stomatal conductance and carbon assimilation rates of the transgenic plants. Normalization of CO2 responses showed that stomata of transgenic plants respond to [CO2] shifts. Detailed stomatal aperture measurements of normal kidney-shaped stomata, which lack chlorophyll, showed stomatal closing responses to [CO2] elevation and abscisic acid (ABA), while thin-shaped stomata were continuously closed. Our present findings show that stomatal movement responses to [CO2] and ABA are functional in guard cells that lack chlorophyll. These data suggest that guard-cell CO2 and ABA signal transduction are not directly modulated by guard-cell photosynthesis/electron transport. Moreover, the finding that chlorophyll-less stomata cause a “deflated” thin-shaped phenotype, suggests that photosynthesis in guard cells is critical for energization and guard-cell turgor production. PMID:26096271

  5. Unexpected Connections between Humidity and Ion Transport Discovered Using a Model to Bridge Guard Cell-to-Leaf Scales.

    PubMed

    Wang, Yizhou; Hills, Adrian; Vialet-Chabrand, Silvere; Papanatsiou, Maria; Griffiths, Howard; Rogers, Simon; Lawson, Tracy; Lew, Virgilio L; Blatt, Michael R

    2017-11-01

    Stomatal movements depend on the transport and metabolism of osmotic solutes that drive reversible changes in guard cell volume and turgor. These processes are defined by a deep knowledge of the identities of the key transporters and of their biophysical and regulatory properties, and have been modeled successfully with quantitative kinetic detail at the cellular level. Transpiration of the leaf and canopy, by contrast, is described by quasilinear, empirical relations for the inputs of atmospheric humidity, CO 2 , and light, but without connection to guard cell mechanics. Until now, no framework has been available to bridge this gap and provide an understanding of their connections. Here, we introduce OnGuard2, a quantitative systems platform that utilizes the molecular mechanics of ion transport, metabolism, and signaling of the guard cell to define the water relations and transpiration of the leaf. We show that OnGuard2 faithfully reproduces the kinetics of stomatal conductance in Arabidopsis thaliana and its dependence on vapor pressure difference (VPD) and on water feed to the leaf. OnGuard2 also predicted with VPD unexpected alterations in K + channel activities and changes in stomatal conductance of the slac1 Cl - channel and ost2 H + -ATPase mutants, which we verified experimentally. OnGuard2 thus bridges the micro-macro divide, offering a powerful tool with which to explore the links between guard cell homeostasis, stomatal dynamics, and foliar transpiration. © 2017 American Society of Plant Biologists. All rights reserved.

  6. 70. Photocopy of 4' 10 x 3'10 Propeller, U.S. Coast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    70. Photocopy of 4' 10 x 3'10 Propeller, U.S. Coast Guard 133 Ft. Tender. Columbian Bronze Corporation, Freeport, Long Island, New York, Coast Guard Headquarters Drawing No. 540-WAGL-4400-4, dated July 1953. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  7. Practical results from a mathematical analysis of guard patrols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Indusi, Joseph P.

    1978-12-01

    Using guard patrols as a primary detection mechanism is not generally viewed as a highly efficient detection method when compared to electronic means. Many factors such as visibility, alertness, and the space-time coincidence of guard and adversary presence all have an effect on the probability of detection. Mathematical analysis of the guard patrol detection problem is related to that of classical search theory originally developed for naval search operations. The results of this analysis tend to support the current practice of using guard forces to assess and respond to previously detected intrusions and not as the primary detection mechanism. 6more » refs.« less

  8. 41 CFR 50-204.5 - Machine guarding.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall... mechanism, so that the barrel, drum or container cannot revolve unless the guard enclosure is in place. (e...

  9. 33 CFR 23.12 - Coast Guard identifying insignia.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (a) The distinctive identification insignia of the Coast Guard consists of a broad diagonal red.... The Coast Guard emblem, as described in § 23.10(b), is centered within the confines of the broad red...

  10. 33 CFR 23.12 - Coast Guard identifying insignia.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (a) The distinctive identification insignia of the Coast Guard consists of a broad diagonal red.... The Coast Guard emblem, as described in § 23.10(b), is centered within the confines of the broad red...

  11. 33 CFR 23.12 - Coast Guard identifying insignia.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (a) The distinctive identification insignia of the Coast Guard consists of a broad diagonal red.... The Coast Guard emblem, as described in § 23.10(b), is centered within the confines of the broad red...

  12. 33 CFR 23.12 - Coast Guard identifying insignia.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (a) The distinctive identification insignia of the Coast Guard consists of a broad diagonal red.... The Coast Guard emblem, as described in § 23.10(b), is centered within the confines of the broad red...

  13. 33 CFR 23.12 - Coast Guard identifying insignia.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (a) The distinctive identification insignia of the Coast Guard consists of a broad diagonal red.... The Coast Guard emblem, as described in § 23.10(b), is centered within the confines of the broad red...

  14. Paul Zukunft « Coast Guard Compass

    Science.gov Websites

    and Maritime Transportation The Coast Guard had a banner year of counter-drug operations in 2016. All suspected drug smugglers were detained and brought to the United States for prosecution. Coast Guard

  15. Guarded capacitance probes for measuring particle concentration and flow

    DOEpatents

    Louge, M.Y.

    1996-08-13

    Guarded capacitance probe structures are constructed with guard electrodes surrounding one or more sensor electrodes and ground electrodes or grounded surfaces surrounding the guard electrodes. In a one sensor embodiment, the probe utilizes an apertured sensor electrode and the guard electrode both surrounds the sensor electrode and fills the aperture. This embodiment is particularly useful for measuring particle concentration in a fluid suspension contained within a vessel or pipe. The portion of the guard electrode within the aperture of the sensor electrode prevents electric field lines from emanating from the sensor electrode into the fluid suspension and toward infinity. A two sensor embodiment of the probe is useful for measuring flow velocities of fluid suspensions through cross correlation of the outputs generated by each sensor. The relative dimensions of the guard and sensor electrodes are selected to provide the most accurate measurements by confining the electric lines emanating from the sensor electrode or electrodes and terminating on the surrounding grounded surfaces to a small measurement volume of the fluid suspension near the vessel or pipe wall. 14 figs.

  16. Guarded capacitance probes for measuring particle concentration and flow

    DOEpatents

    Louge, M.Y.

    1995-10-17

    Guarded capacitance probe structures are constructed with guard electrodes surrounding one or more sensor electrodes and ground electrodes or grounded surfaces surrounding the guard electrodes. In a one sensor embodiment, the probe utilizes an apertured sensor electrode and the guard electrode both surrounds the sensor electrode and fills the aperture. This embodiment is particularly useful for measuring particle concentration in a fluid suspension contained within a vessel or pipe. The portion of the guard electrode within the aperture of the sensor electrode prevents electric field lines from emanating from the sensor electrode into the fluid suspension and toward infinity. A two sensor embodiment of the probe is useful for measuring flow velocities of fluid suspensions through cross correlation of the outputs generated by each sensor. The relative dimensions of the guard and sensor electrodes are selected to provide the most accurate measurements by confining the electric lines emanating from the sensor electrode or electrodes and terminating on the surrounding grounded surfaces to a small measurement volume of the fluid suspension near the vessel or pipe wall. 14 figs.

  17. Guarded capacitance probes for measuring particle concentration and flow

    DOEpatents

    Louge, Michel Y.

    1995-01-01

    Guarded capacitance probe structures are constructed with guard electrodes surrounding one or more sensor electrodes and ground electrodes or grounded surfaces surrounding the guard electrodes. In a one sensor embodiment, the probe utilizes an apertured sensor electrode and the guard electrode both surrounds the sensor electrode and fills the aperture. This embodiment is particularly useful for measuring particle concentration in a fluid suspension contained within a vessel or pipe. The portion of the guard electrode within the aperture of the sensor electrode prevents electric field lines from emanating from the sensor electrode into the fluid suspension and toward infinity. A two sensor embodiment of the probe is useful for measuring flow velocities of fluid suspensions through cross correlation of the outputs generated by each sensor. The relative dimensions of the guard and sensor electrodes are selected to provide the most accurate measurements by confining the electric lines emanating from the sensor electrode or electrodes and terminating on the surrounding grounded surfaces to a small measurement volume of the fluid suspension near the vessel or pipe wall.

  18. Guarded capacitance probes for measuring particle concentration and flow

    DOEpatents

    Louge, Michel Y.

    1996-01-01

    Guarded capacitance probe structures are constructed with guard electrodes surrounding one or more sensor electrodes and ground electrodes or grounded surfaces surrounding the guard electrodes. In a one sensor embodiment, the probe utilizes an apertured sensor electrode and the guard electrode both surrounds the sensor electrode and fills the aperture. This embodiment is particularly useful for measuring particle concentration in a fluid suspension contained within a vessel or pipe. The portion of the guard electrode within the aperture of the sensor electrode prevents electric field lines from emanating from the sensor electrode into the fluid suspension and toward infinity. A two sensor embodiment of the probe is useful for measuring flow velocities of fluid suspensions through cross correlation of the outputs generated by each sensor. The relative dimensions of the guard and sensor electrodes are selected to provide the most accurate measurements by confining the electric lines emanating from the sensor electrode or electrodes and terminating on the surrounding grounded surfaces to a small measurement volume of the fluid suspension near the vessel or pipe wall.

  19. Actin filaments regulate the adhesion between the plasma membrane and the cell wall of tobacco guard cells.

    PubMed

    Yu, Qin; Ren, Jing-Jing; Kong, Lan-Jing; Wang, Xiu-Ling

    2018-01-01

    During the opening and closing of stomata, guard cells undergo rapid and reversible changes in their volume and shape, which affects the adhesion of the plasma membrane (PM) to the cell wall (CW). The dynamics of actin filaments in guard cells are involved in stomatal movement by regulating structural changes and intracellular signaling. However, it is unclear whether actin dynamics regulate the adhesion of the PM to the CW. In this study, we investigated the relationship between actin dynamics and PM-CW adhesion by the hyperosmotic-induced plasmolysis of tobacco guard cells. We found that actin filaments in guard cells were depolymerized during mannitol-induced plasmolysis. The inhibition of actin dynamics by treatment with latrunculin B or jasplakinolide and the disruption of the adhesion between the PM and the CW by treatment with RGDS peptide (Arg-Gly-Asp-Ser) enhanced guard cell plasmolysis. However, treatment with latrunculin B alleviated the RGDS peptide-induced plasmolysis and endocytosis. Our results reveal that the actin depolymerization is involved in the regulation of the PW-CW adhesion during hyperosmotic-induced plasmolysis in tobacco guard cells.

  20. Coast Guard : budget challenges for 2001 and beyond

    DOT National Transportation Integrated Search

    2000-03-15

    The testimony today, which is based on recently completed and ongoing work, addresses two topics: (1) the Coast Guard's progress in justifying and managing its Deepwater Project and (2) opportunities for improving the Coast Guard's operating efficien...

  1. 75 FR 68663 - Federal Motor Vehicle Safety Standards; Rear Impact Guards; Rear Impact Protection; Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-08

    ... Report, on the Effectiveness of Underride Guards for Heavy Trailers AGENCY: National Highway Traffic...: The Effectiveness of Underride Guards for Heavy Trailers. DATES: Comments must be received no later...

  2. Designing a Maintainable and Sustainable Coast Guard Icebreaker for Arctic and Antarctic Operations

    DTIC Science & Technology

    2014-03-21

    03-2014 Technical June 2013-August 2013 Designing a Maintainable and Sustainable Coast Guard Icebreaker for Arctic and Antarctic Operations...of Engineering Designing a Maintainable and Sustainable Coast Guard Icebreaker for Arctic and Antarctic Operations Abstract The U.S. Coast Guard is...Pollution (MARPOL) of which Annex V prohibits the discharge of solid waste other than food refuge less than 25mm in diameter into the Antarctic Region [6

  3. Women's Fertility Status Alters Other Women's Jealousy and Mate Guarding.

    PubMed

    Hurst, Ashalee C; Alquist, Jessica L; Puts, David A

    2017-02-01

    Across three studies, we tested the hypothesis that women exhibit greater jealousy and mate guarding toward women who are in the high (vs. low) fertility phase of their cycle. Women who imagined their partner with a woman pictured at high fertility reported more jealousy than women who imagined their partner with a woman pictured at low fertility (Studies 1 and 2). A meta-analysis across studies manipulating fertility status of the pictured woman found a significant effect of fertility status on both jealousy and mate guarding. Women with attractive partners viewed fertile-phase women as less trustworthy, which led to increased mate guarding (Study 2). In Study 3, the closer women were to peak fertility, the more instances they reported of other women acting jealously and mate guarding toward them. These studies provide evidence that women selectively exhibit jealousy and mate guarding toward women who are near peak fertility.

  4. Prevention of CO2 laser-induced endotracheal tube fires with the laser-guard protective coating.

    PubMed

    Sosis, M B; Dillon, F

    1992-01-01

    To determine how well Laser-Guard protects polyvinyl chloride (PVC) endotracheal tubes from the carbon dioxide (CO2) laser. Bare and Laser-Guard-protected PVC endotracheal tubes were tested with 5 L/min of oxygen (O2) passing through them. Research laboratory of a university-affiliated metropolitan medical center. After moistening the Laser-Guard-protected endotracheal tubes, we subjected the tubes to CO2 laser radiation at 10 and 70 watts until combustion occurred or 60 seconds had elapsed. The bare PVC tube ignited and a "blowtorch" fire occurred after 3 seconds of CO2 laser use at 70 watts. The moistened Laser-Guard-protected PVC endotracheal tubes were not significantly damaged by 1 minute of laser use at 70 watts. Laser-Guard protects the shafts of combustible PVC endotracheal tubes from direct, high-power, continuous CO2 laser radiation.

  5. Sensory Transduction and Electrical Signaling in Guard Cells

    PubMed Central

    Serrano, Elba E.; Zeiger, Eduardo

    1989-01-01

    Guard cells are a valuable model system for the study of photoreception, ion transport, and osmoregulation in plant cells. Changes in stomatal apertures occur when sensing mechanisms within the guard cells transduce environmental stimull into the ion fluxes and biosynthesis of organic solutes that regulate turgor. The electrical events mediating sensory transduction in guard cells can be characterized with a variety of electrophysiological recording techniques. Recent experiments applying the patch clamp method to guard cell protoplasts have demonstrated activation of electrogenic pumps by blue and red light as well as the presence of potassium channels in guard cell plasmalemma. Light activation of electrogenic proton pumping and the ensuing gating of voltage-dependent ion channels appear to be components of sensory transduction of the stomatal response to light. Mechanisms underlying stomatal control by environmental signals can be understood by studying electrical events associated with ion transport. PMID:16667138

  6. Functional analysis of cellulose and xyloglucan in the walls of stomatal guard cells of Arabidopsis thaliana

    DOE PAGES

    Rui, Yue; Anderson, Charles T.

    2016-01-04

    Here, stomatal guard cells are pairs of specialized epidermal cells that control water and CO 2 exchange between the plant and the environment. To fulfill the functions of stomatal opening and closure that are driven by changes in turgor pressure, guard cell walls must be both strong and flexible, but how the structure and dynamics of guard cell walls enable stomatal function remains poorly understood. To address this question, we applied cell biological and genetic analyses to investigate guard cell walls and their relationship to stomatal function in Arabidopsis ( Arabidopsis thaliana). Using live-cell spinning disk confocal microscopy, we measuredmore » the motility of cellulose synthase (CESA)-containing complexes labeled by green fluorescent protein (GFP)-CESA3 and observed a reduced proportion of GFP-CESA3 particles colocalizing with microtubules upon stomatal closure. Imaging cellulose organization in guard cells revealed a relatively uniform distribution of cellulose in the open state and a more fibrillar pattern in the closed state, indicating that cellulose microfibrils undergo dynamic reorganization during stomatal movements. In cesa3 je5 mutants defective in cellulose synthesis and xxt1 xxt2 mutants lacking the hemicellulose xyloglucan, stomatal apertures, changes in guard cell length, and cellulose reorganization were aberrant during fusicoccin-induced stomatal opening or abscisic acid-induced stomatal closure, indicating that sufficient cellulose and xyloglucan are required for normal guard cell dynamics. Together, these results provide new insights into how guard cell walls allow stomata to function as responsive mediators of gas exchange at the plant surface.« less

  7. Exploring the Public Health Impacts of Private Security Guards on People Who Use Drugs: a Qualitative Study.

    PubMed

    Markwick, Nicole; McNeil, Ryan; Small, Will; Kerr, Thomas

    2015-12-01

    Private security guards occupy an increasingly prominent role in the policing of private and public spaces. There are growing concerns regarding security guards' potential to shape violence, discrimination, and adverse health outcomes among vulnerable populations, including people who use drugs (PWUD). This is relevant in Vancouver, Canada, where private security guards have increasingly been employed by private organizations to manage public and private spaces, including those within urban drug scenes. This qualitative study sought to understand interactions between PWUD and private security guards and explore their impacts on health care access, risks, and harms among PWUD. Semi-structured interviews were conducted with 30 PWUD recruited from two ongoing prospective cohort studies. Interviews were transcribed and analyzed using a coding framework comprised of a priori and emergent categories. Study data indicate that participants experience pervasive, discriminatory profiling and surveillance by security guards, which exacerbates existing social marginalization and structural vulnerability, particularly among PWUD of Aboriginal ancestry. Participants reported that security guards restrict PWUD's access to public and private spaces, including pharmacies and hospitals. PWUD also reported that their interactions with security guards often involved interpersonal violence and aggression, experiences that served to increase their vulnerability to subsequent risks and harms. Our findings highlight that private security forces contribute significantly to the everyday violence experienced by PWUD within drug scenes and elsewhere and do so in a manner very similar to that of traditional police forces. These findings point to the urgent need for greater oversight and training of private security guards in order to protect the health and safety of PWUD.

  8. Exploring emergent properties in cellular homeostasis using OnGuard to model K+ and other ion transport in guard cells☆☆☆

    PubMed Central

    Blatt, Michael R.; Wang, Yizhou; Leonhardt, Nathalie; Hills, Adrian

    2014-01-01

    It is widely recognized that the nature and characteristics of transport across eukaryotic membranes are so complex as to defy intuitive understanding. In these circumstances, quantitative mathematical modeling is an essential tool, both to integrate detailed knowledge of individual transporters and to extract the properties emergent from their interactions. As the first, fully integrated and quantitative modeling environment for the study of ion transport dynamics in a plant cell, OnGuard offers a unique tool for exploring homeostatic properties emerging from the interactions of ion transport, both at the plasma membrane and tonoplast in the guard cell. OnGuard has already yielded detail sufficient to guide phenotypic and mutational studies, and it represents a key step toward ‘reverse engineering’ of stomatal guard cell physiology, based on rational design and testing in simulation, to improve water use efficiency and carbon assimilation. Its construction from the HoTSig libraries enables translation of the software to other cell types, including growing root hairs and pollen. The problems inherent to transport are nonetheless challenging, and are compounded for those unfamiliar with conceptual ‘mindset’ of the modeler. Here we set out guidelines for the use of OnGuard and outline a standardized approach that will enable users to advance quickly to its application both in the classroom and laboratory. We also highlight the uncanny and emergent property of OnGuard models to reproduce the ‘communication’ evident between the plasma membrane and tonoplast of the guard cell. PMID:24268743

  9. Exploring emergent properties in cellular homeostasis using OnGuard to model K+ and other ion transport in guard cells.

    PubMed

    Blatt, Michael R; Wang, Yizhou; Leonhardt, Nathalie; Hills, Adrian

    2014-05-15

    It is widely recognized that the nature and characteristics of transport across eukaryotic membranes are so complex as to defy intuitive understanding. In these circumstances, quantitative mathematical modeling is an essential tool, both to integrate detailed knowledge of individual transporters and to extract the properties emergent from their interactions. As the first, fully integrated and quantitative modeling environment for the study of ion transport dynamics in a plant cell, OnGuard offers a unique tool for exploring homeostatic properties emerging from the interactions of ion transport, both at the plasma membrane and tonoplast in the guard cell. OnGuard has already yielded detail sufficient to guide phenotypic and mutational studies, and it represents a key step toward 'reverse engineering' of stomatal guard cell physiology, based on rational design and testing in simulation, to improve water use efficiency and carbon assimilation. Its construction from the HoTSig libraries enables translation of the software to other cell types, including growing root hairs and pollen. The problems inherent to transport are nonetheless challenging, and are compounded for those unfamiliar with conceptual 'mindset' of the modeler. Here we set out guidelines for the use of OnGuard and outline a standardized approach that will enable users to advance quickly to its application both in the classroom and laboratory. We also highlight the uncanny and emergent property of OnGuard models to reproduce the 'communication' evident between the plasma membrane and tonoplast of the guard cell. Copyright © 2014 The Authors. Published by Elsevier GmbH.. All rights reserved.

  10. Functional Analysis of Cellulose and Xyloglucan in the Walls of Stomatal Guard Cells of Arabidopsis1[OPEN

    PubMed Central

    Rui, Yue; Anderson, Charles T.

    2016-01-01

    Stomatal guard cells are pairs of specialized epidermal cells that control water and CO2 exchange between the plant and the environment. To fulfill the functions of stomatal opening and closure that are driven by changes in turgor pressure, guard cell walls must be both strong and flexible, but how the structure and dynamics of guard cell walls enable stomatal function remains poorly understood. To address this question, we applied cell biological and genetic analyses to investigate guard cell walls and their relationship to stomatal function in Arabidopsis (Arabidopsis thaliana). Using live-cell spinning disk confocal microscopy, we measured the motility of cellulose synthase (CESA)-containing complexes labeled by green fluorescent protein (GFP)-CESA3 and observed a reduced proportion of GFP-CESA3 particles colocalizing with microtubules upon stomatal closure. Imaging cellulose organization in guard cells revealed a relatively uniform distribution of cellulose in the open state and a more fibrillar pattern in the closed state, indicating that cellulose microfibrils undergo dynamic reorganization during stomatal movements. In cesa3je5 mutants defective in cellulose synthesis and xxt1 xxt2 mutants lacking the hemicellulose xyloglucan, stomatal apertures, changes in guard cell length, and cellulose reorganization were aberrant during fusicoccin-induced stomatal opening or abscisic acid-induced stomatal closure, indicating that sufficient cellulose and xyloglucan are required for normal guard cell dynamics. Together, these results provide new insights into how guard cell walls allow stomata to function as responsive mediators of gas exchange at the plant surface. PMID:26729799

  11. Truck side guard technical overview : safety and operational considerations

    DOT National Transportation Integrated Search

    2015-04-23

    This technical overview provides safety and operational considerations for truck side guards. Truck side guards are designed to keep pedestrians, bicyclists, and motorcyclists - known as vulnerable road users (VRUs) from being run over by a large tru...

  12. Cytochemical and Cytofluorometric Evidence for Guard Cell Photosystems 1

    PubMed Central

    Vaughn, Kevin C.; Outlaw, William H.

    1983-01-01

    Evidence for photosynthetic linear electron transport in guard cells was obtained with two sensitive methods of high spacial resolution. Light-dependent diaminobenzidine oxidation (an indicator of PSI) and DCMU-sensitive, light-dependent thiocarbamyl nitroblue tetrazolium reduction (an indicator of PSII) were observed in guard cell plastids of Hordeum vulgare L. cv Himalaya using electron microscopic cytochemical procedures. DCMU-sensitive Chl a fluorescence induction (an indicator of PSII) was detected in individual guard cell pairs of Vicia faba L. cv Longpod using an ultramicrofluorometer. At least for these species, we conclude these results are proof for the presence of PSII in guard cell chloroplasts, which until now has been somewhat controversial. Images Fig. 2 Fig. 1 PMID:16662840

  13. Redesign of Advanced Education Processes the United States Coast Guard

    DTIC Science & Technology

    1999-09-01

    educational level. Els are assigned to help track individuals with specialized training and to facilitate statistical data collection. The El is used by...just like every other officer in the Coast Guard. Currently, the Coast Guard’s personnel database does not include data on advanced education ...Appendix A. 56 • Advanced Education is not a searchable field in the Coast Guard’s Personnel Data System. PMs and AOs do not have direct access to

  14. GUARD HOUSE AND SOUTH FIRE HOUSE, VICINITY MAP. (Shows the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    GUARD HOUSE AND SOUTH FIRE HOUSE, VICINITY MAP. (Shows the Guard House and Barracks, and South Fire House in relation to nearby roads, railroad tracks, and the piers). Navy Yard, Mare Island, California. P.W. Drawing No. C-1899, approved 1941; file no. 930-C-1. Scale one inch to forty feet. 72 cn x 97 cm. Ink on vellum - Mare Island Naval Shipyard, Guard House & Barracks, Railroad Avenue near Eighteenth Street, Vallejo, Solano County, CA

  15. United States Coast Guard 2010 Posture Statement: With 2011 Budget in Brief

    DTIC Science & Technology

    2010-02-01

    marine animals and plants, and prevents foreign poaching out to 200 miles offshore. Did you know? Coast Guard Hero Petty Offi cer 3rd Class Caleb S...Code). Did you know? U.S. Coast Guard Posture Statement • 17 Coast Guard Missions hazardous substance accidents and reduce their impact on the...inspects all vessels’ ballast water before they enter the Great Lakes to prevent invasive species from inhabiting the ecosystem . Photo by PA3 William

  16. Photocopy of plan (in collection of U.S. Coast Guard Civil ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of plan (in collection of U.S. Coast Guard Civil Engineering Unit Providence, Warwick, RI), U.S. Coast Guard Civil Engineering, third district, Sandy Hook L/B Station, Fort Hancock, NJ, boathouse, plot plan, floor plan, elevation. & section., November 8, 1963 Proposed boathouse wharf B, L.A.S. building shown on wharf A - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  17. Photocopy of plan (in collection of U.S. Coast Guard Civil ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of plan (in collection of U.S. Coast Guard Civil Engineering Unit Providence, Warwick, RI), U.S. Coast Guard Civil Engineering, third district, Sandy Hook L/B Station, Sandy Hook N.J., buoy hoist installation and bldg alterations, January 3, 1952 Details of 4 ton hoist and building, wharf B - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  18. Photocopy of plan (in collection of U.S. Coast Guard Civil ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of plan (in collection of U.S. Coast Guard Civil Engineering Unit Providence, Warwick, RI) U.S. Coast Guard, shore maintenance detachment, New York, mooring facilities for 110 WPB's Station Sandy Hook, Middletown Township, New Jersey, civil demolition of wharf & pier E December 22, 1988 detail of framing and decking wharf B - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  19. Automated intracranial pressure-controlled cerebrospinal fluid external drainage with LiquoGuard.

    PubMed

    Linsler, Stefan; Schmidtke, Mareike; Steudel, Wolf Ingo; Kiefer, Michael; Oertel, Joachim

    2013-08-01

    LiquoGuard is a new device for intracranial pressure (ICP)-controlled drainage of cerebrospinal fluid (CSF). This present study evaluates the accuracy of ICP measurement via the LiquoGuard device in comparison with Spiegelberg. Thus, we compared data ascertained from simultaneous measurement of ICP using tip-transducer and tip-sensor devices. A total of 1,764 monitoring hours in 15 patients (range, 52-219 h) were analysed. All patients received an intraventricular Spiegelberg III probe with the drainage catheter connected to the LiquoGuard system. ICP reading of both devices was performed on an hourly basis. Statistical analysis was done by applying Pearson correlation and Wilcoxon-matched pair test (p < 0.05). Mean ICP values were 11 ± 5 mmHg (Spiegelberg) and 10 ± 7 mmHg (LiquoGuard); the values measured with both devices correlated well (p = 0.001; Pearson correlation =0.349; n = 1,764). In two of the 15 patients with slit ventricles, episodes of significant differences in measured values could be observed. Both patients suffering from slit ventricles failed to produce reliable measurement with the external transducer of the LiquoGuard. LiquoGuard is a valuable new device for ICP-controlled CSF drainage. However, LiquoGuard tends to provide misleading results in slit ventricles. Thus, before these drawbacks are further analysed, the authors recommend additional ICP measurement with internal tip-sensor devices to avoid dangerous erroneous interpretation of ICP data.

  20. Cameleon calcium indicator reports cytoplasmic calcium dynamics in Arabidopsis guard cells

    NASA Technical Reports Server (NTRS)

    Allen, G. J.; Kwak, J. M.; Chu, S. P.; Llopis, J.; Tsien, R. Y.; Harper, J. F.; Schroeder, J. I.; Evans, M. L. (Principal Investigator)

    1999-01-01

    Cytoplasmic free calcium ([Ca2+]cyt) acts as a stimulus-induced second messenger in plant cells and multiple signal transduction pathways regulate [Ca2+]cyt in stomatal guard cells. Measuring [Ca2+]cyt in guard cells has previously required loading of calcium-sensitive dyes using invasive and technically difficult micro-injection techniques. To circumvent these problems, we have constitutively expressed the pH-independent, green fluorescent protein-based calcium indicator yellow cameleon 2.1 in Arabidopsis thaliana (Miyawaki et al. 1999; Proc. Natl. Acad. Sci. USA 96, 2135-2140). This yellow cameleon calcium indicator was expressed in guard cells and accumulated predominantly in the cytoplasm. Fluorescence ratio imaging of yellow cameleon 2.1 allowed time-dependent measurements of [Ca2+]cyt in Arabidopsis guard cells. Application of extracellular calcium or the hormone abscisic acid (ABA) induced repetitive [Ca2+]cyt transients in guard cells. [Ca2+]cyt changes could be semi-quantitatively determined following correction of the calibration procedure for chloroplast autofluorescence. Extracellular calcium induced repetitive [Ca2+]cyt transients with peak values of up to approximately 1.5 microM, whereas ABA-induced [Ca2+]cyt transients had peak values up to approximately 0.6 microM. These values are similar to stimulus-induced [Ca2+]cyt changes previously reported in plant cells using ratiometric dyes or aequorin. In some guard cells perfused with low extracellular KCl concentrations, spontaneous calcium transients were observed. As yellow cameleon 2.1 was expressed in all guard cells, [Ca2+]cyt was measured independently in the two guard cells of single stomates for the first time. ABA-induced, calcium-induced or spontaneous [Ca2+]cyt increases were not necessarily synchronized in the two guard cells. Overall, these data demonstrate that that GFP-based cameleon calcium indicators are suitable to measure [Ca2+]cyt changes in guard cells and enable the pattern of [Ca2+]cyt dynamics to be measured with a high level of reproducibility in Arabidopsis cells. This technical advance in combination with cell biological and molecular genetic approaches will become an invaluable tool in the dissection of plant cell signal transduction pathways.

  1. 33 CFR 53.5 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... member of a Department of Defense or Department of Homeland Security audit, inspection, investigation, or... Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PERSONNEL COAST GUARD... Department of Homeland Security Board for Correction of Military Records of the Coast Guard (Board) is...

  2. 75 FR 49836 - Iranian Financial Sanctions Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-16

    ... Iran's Islamic Revolutionary Guard Corps (``IRGC'') or certain other blocked persons. Specifically...) Facilitates the efforts of the Government of Iran (including efforts of Iran's Islamic Revolutionary Guard... transactions or provides significant financial services for-- (i) Iran's Islamic Revolutionary Guard Corps or...

  3. Register of Cutters of the U.S. Coast Guard

    DOT National Transportation Integrated Search

    1996-11-18

    The Manual Publishes the Register of Cutters of the U.S. Coast Guard and : provides an official listing of all Coast Guard cutters as of 01 August 1996. : It includes permanent stations and selected characteristics of all cutters. : Endurance figures...

  4. Overview of the U.S. Coast Guard short range aids to navigation mission

    DOT National Transportation Integrated Search

    1993-09-01

    This document provides an overview of the Coast Guard's Aids to Navigation (ATON) mission. Specific components of the mission described within include: the history of the mission; the supporting Coast Guard organizational structure; the resources emp...

  5. Cell block one and southeast guard tower, looking from the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Cell block one and southeast guard tower, looking from the central guard tower, facing southeast (note view also includes cell block ten (left) and cell block nine (right)) - Eastern State Penitentiary, 2125 Fairmount Avenue, Philadelphia, Philadelphia County, PA

  6. Disaster Relief: Oklahoma Tornadoes

    Science.gov Websites

    as citizen soldiers and airmen serving their communities. Story Oklahoma Airman Experiences Moore , Okla. Video Video: Guard Tornado Response Defines "Citizen Soldier" Guard Tornado Response Defines "Citizen Soldier" More Videos Interview with BG Emery Fountain on National Guard

  7. Guard cell photosynthesis is critical for stomatal turgor production, yet does not directly mediate CO2 - and ABA-induced stomatal closing.

    PubMed

    Azoulay-Shemer, Tamar; Palomares, Axxell; Bagheri, Andisheh; Israelsson-Nordstrom, Maria; Engineer, Cawas B; Bargmann, Bastiaan O R; Stephan, Aaron B; Schroeder, Julian I

    2015-08-01

    Stomata mediate gas exchange between the inter-cellular spaces of leaves and the atmosphere. CO2 levels in leaves (Ci) are determined by respiration, photosynthesis, stomatal conductance and atmospheric [CO2 ]. [CO2 ] in leaves mediates stomatal movements. The role of guard cell photosynthesis in stomatal conductance responses is a matter of debate, and genetic approaches are needed. We have generated transgenic Arabidopsis plants that are chlorophyll-deficient in guard cells only, expressing a constitutively active chlorophyllase in a guard cell specific enhancer trap line. Our data show that more than 90% of guard cells were chlorophyll-deficient. Interestingly, approximately 45% of stomata had an unusual, previously not-described, morphology of thin-shaped chlorophyll-less stomata. Nevertheless, stomatal size, stomatal index, plant morphology, and whole-leaf photosynthetic parameters (PSII, qP, qN, FV '/FM' ) were comparable with wild-type plants. Time-resolved intact leaf gas-exchange analyses showed a reduction in stomatal conductance and CO2 -assimilation rates of the transgenic plants. Normalization of CO2 responses showed that stomata of transgenic plants respond to [CO2 ] shifts. Detailed stomatal aperture measurements of normal kidney-shaped stomata, which lack chlorophyll, showed stomatal closing responses to [CO2 ] elevation and abscisic acid (ABA), while thin-shaped stomata were continuously closed. Our present findings show that stomatal movement responses to [CO2 ] and ABA are functional in guard cells that lack chlorophyll. These data suggest that guard cell CO2 and ABA signal transduction are not directly modulated by guard cell photosynthesis/electron transport. Moreover, the finding that chlorophyll-less stomata cause a 'deflated' thin-shaped phenotype, suggests that photosynthesis in guard cells is critical for energization and guard cell turgor production. © 2015 The Authors The Plant Journal © 2015 John Wiley & Sons Ltd.

  8. Scientific evaluation of the ArmorGuard mobile barrier system.

    DOT National Transportation Integrated Search

    2011-06-17

    "Accidents and injuries occur during maintenance activities that could be protected by the ArmorGuard or BalsiBeam mobile barrier systems. The main purpose of this study is to perform a scientific evaluation of the utility of the ArmorGuard system in...

  9. Commandant Instruction 1020.11A: Coast Guard Hot Weather Boat Outfit

    DOT National Transportation Integrated Search

    1997-06-09

    Authorizes the Coast Guard Hot Weather Boat Crew Outfit as organizational : clothing. It also provides-up-to date guidance identifying when the Coast Guard : Hot Weather Boat Crew Outfit is appropriate for wear; the outfit's components; : and where t...

  10. FIRE STATION AND GUARD HOUSE, ELEVATIONS, SECTIONS, AND DETAILS. Plan ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FIRE STATION AND GUARD HOUSE, ELEVATIONS, SECTIONS, AND DETAILS. Plan No. 6754-320, dated August 1, 1933. Constructing Division, Office of the Constructing Quartermaster - Hamilton Field, Fire Station & Guard House, Southwest corner of Seventh Street & Hangar Avenue, Novato, Marin County, CA

  11. FIRE STATION AND GUARD HOUSE, PLANS AND DETAILS. Plan No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FIRE STATION AND GUARD HOUSE, PLANS AND DETAILS. Plan No. 6754-319, dated August 1, 1933. Construction Division, Office of the Constructing Quartermaster - Hamilton Field, Fire Station & Guard House, Southwest corner of Seventh Street & Hangar Avenue, Novato, Marin County, CA

  12. 99. Catalog HHistory 1, C.C.C., 23 Guard Rail Construction, Negative ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    99. Catalog H-History 1, C.C.C., 23 Guard Rail Construction, Negative No. P455e (Photographer and date unknown) GUARD RAIL INSTALLATION. - Skyline Drive, From Front Royal, VA to Rockfish Gap, VA , Luray, Page County, VA

  13. 35. INTERIOR VIEW OF THE GUARD LOCKS LOCK HOUSE: CLOSED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. INTERIOR VIEW OF THE GUARD LOCKS LOCK HOUSE: CLOSED LOCK GATES AND TWO SETS OF MACHINERY TO ASSIST IN OPERATING THEM. VIEW FROM THE FAST END OF THE BUILDING LOOKING WEST 1976 - Pawtucket Canal, Guard Locks, Lowell, Middlesex County, MA

  14. Research Methods to Develop Measures of Effectiveness of the United States Coast Guard’s Vessel Inspection and Boarding Program. Executive Summary - Volume I

    DTIC Science & Technology

    1995-05-01

    Service, Springfield, Virginia 22161 Prepared for: LJCý U.S. Coast Guard Research and Development Center 1082 Shennecossett Road < Groton, Connecticut...States Coast Guard Research & Development Center 1082 Shennecossett Road Groton, CT 06340-6096 ii Technical Report Documentation Paae 1. Report No. 2...U.S. Coast Guard 14. Sponsoring Agency Code Research and Development Center Office of Engineering, Logistics, 1082 Shennecossett Road and Development

  15. Offshore Installations and Their Relevance to the Coast Guard through the Next Twenty-Five Years. Volume I. Basic Report: Forecast of Offshore Installations and Their Implications to the Coast Guard.

    DTIC Science & Technology

    1980-11-01

    institution to impose charges on members of the Coast Guard’s constituency who benefit from Coast Guard sevices --i.e. establish user charges and value... Sex Ratio - Externalities * Labor Force - Relation to economic growth - Nature and number - Man’s welfare - Participation rate - Productivity rate...Pollution characterisitcs - Sex distribution Radioactive e By Country Thermal Toxic 9 Structure Contanimant - Stratification Long run/short run

  16. Longevity of guard cell chloroplasts in falling leaves: implication for stomatal function and cellular aging.

    PubMed

    Zeiger, E; Schwartz, A

    1982-11-12

    Guard cell chloroplasts in senescing leaves from 12 species of perennial trees and three species of annual plants survived considerably longer than their mesophyll counterparts. In Ginkgo biloba, stomata from yellow leaves opened during the day and closed at night; guard cell chloroplasts from these leaves showed fluorescence transients associated with electron transport and photophosphorylation. These findings indicate that guard cell chloroplasts are highly conserved throughout the life-span of the leaf and that leaves retain stomatal control during senescence.

  17. Airpower Against an Army: Challenge and Response in CENTAF’S Duel with the Republican Guard

    DTIC Science & Technology

    1995-06-01

    Challenge and Response in CENTAF’S Duel with the Republican Guard Contract or Grant Number Program Element Number Authors Andrews, William F...unlimited Number of Pages 140 AIRPOWER AGAINST AN ARMY CHALLENGE AND RESPONSE IN CENTAF’S DUEL WITH THE REPUBLICAN GUARD BY WILLIAM F. ANDREWS A THESIS...of the battle had been shaped by CENTAF’s month long duel with the Iraqi Army. As the first troops crossed the Iraqi border the Republican Guard heavy

  18. Longevity of guard cell chloroplasts in falling leaves: implication for stomatal function and cellular aging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeiger, E.; Schwartz, A.

    1982-11-12

    Guard cell chloroplasts in senescing leaves from 12 species of perennial trees and three species of annual plants survived considerably longer than their mesophyll counterparts. In Ginkgo biloba, stomata from yellow leaves opened during the day and closed at night; guard cell chloroplasts from these leaves showed fluorescence transients associated with electron transport and photophosphorylation. These findings indicate that guard cell chloroplasts are highly conserved throughout the life-span of the leaf and that leaves retain stomatal control during senescence.

  19. A Multiprocessor Implementation of CSP (Communicating Sequential Processes)

    DTIC Science & Technology

    1988-03-01

    P to check that "valid" communications can take place between P using guard g , and P,, and if so, to attempt to commit to P,. If a commit was...AltList,, gi): INTEGER that scans the remote alternative list AltList, looking for a matching and corn- patible guard g , to the local guard g ,. By...matching we mean gj contains an I/O operation with P. By compatible we mean g , and gj do not both contain input (output) commands. CheckGuard returns j

  20. Egg-guarding behavior of the treehopper Ennya chrysura (Hemiptera: Membracidae): female aggregations, egg parasitism, and a possible substrate-borne alarm signal.

    PubMed

    Miranda, Ximena

    2016-09-01

    Treehoppers are known for their substrate-borne communication and some of them also for their subsocial behavior. Following a more general study of the natural history and substrate-borne signal repertoire of the treehopper Ennya chrysura, the objective of this paper was to explore in greater depth the signals and other behaviors associated specifically to egg-guarding. Theese were studied both in natural and laboratory conditions between July, 2000 and March, 2004. The spacial distribution of egg guarding females was studied in the natural population; recording equipment and playback experiments were used in the laboratory and then analyzed digitally. Under natural conditions (San Antonio de Escazú, Costa Rica), female E. chrysura guard their egg masses and egg-guarding was associated with lower parasitism of the eggs from the wasps Gonatocerus anomocerus and Schizophragma sp. (Mymaridae). Females tended to place their eggs close to other egg-guarding females and they produced substrate-borne vibrations when disturbed. An aggregated pattern under natural conditions was confirmed by calculating dispersion indices from egg-clutch data obtained from 66 leaves in the field. The disturbance signal was characterized from laboratory recordings of substrate-borne vibrations of 10 egg-guarding females. Experiments conducted in the laboratory with 18 egg-guarding females showed that those which were previously exposed to the disturbance signal of another female moved slightly or vibrated more during playbacks and that they reacted more quickly and exhibited more deffensive behaviors in response to a tactile stimulus. The signals produced while defending against egg parasites may therefore function as an alarm and favor aggregating behavior of egg-guarding females.

  1. Stomatal Function Requires Pectin De-methyl-esterification of the Guard Cell Wall

    DOE PAGES

    Amsbury, Sam; Hunt, Lee; Elhaddad, Nagat; ...

    2016-10-06

    Stomatal opening and closure depends on changes in turgor pressure acting within guard cells to alter cell shape. The extent of these shape changes is limited by the mechanical properties of the cells, which will be largely dependent on the structure of the cell walls. Although it has long been observed that guard cells are anisotropic due to differential thickening and the orientation of cellulose microfibrils, our understanding of the composition of the cell wall that allows them to undergo repeated swelling and deflation remains surprisingly poor. Here, we show that the walls of guard cells are rich in un-esterified pectins.more » We identify a pectin methylesterase gene, PME6, which is highly expressed in guard cells and required for stomatal function. pme6-1 mutant guard cells have walls enriched in methyl-esterified pectin and show a decreased dynamic range in response to triggers of stomatal opening/closure, including elevated osmoticum, suggesting that abrogation of stomatal function reflects a mechanical change in the guard cell wall. Altered stomatal function leads to increased conductance and evaporative cooling, as well as decreased plant growth. The growth defect of the  pme6-1 mutant is rescued by maintaining the plants in elevated CO 2, substantiating gas exchange analyses, indicating that the mutant stomata can bestow an improved assimilation rate. Restoration of PME6 rescues guard cell wall pectin methyl-esterification status, stomatal function, and plant growth. Our results establish a link between gene expression in guard cells and their cell wall properties, with a corresponding effect on stomatal function and plant physiology.« less

  2. OnGuard, a Computational Platform for Quantitative Kinetic Modeling of Guard Cell Physiology1[W][OA

    PubMed Central

    Hills, Adrian; Chen, Zhong-Hua; Amtmann, Anna; Blatt, Michael R.; Lew, Virgilio L.

    2012-01-01

    Stomatal guard cells play a key role in gas exchange for photosynthesis while minimizing transpirational water loss from plants by opening and closing the stomatal pore. Foliar gas exchange has long been incorporated into mathematical models, several of which are robust enough to recapitulate transpirational characteristics at the whole-plant and community levels. Few models of stomata have been developed from the bottom up, however, and none are sufficiently generalized to be widely applicable in predicting stomatal behavior at a cellular level. We describe here the construction of computational models for the guard cell, building on the wealth of biophysical and kinetic knowledge available for guard cell transport, signaling, and homeostasis. The OnGuard software was constructed with the HoTSig library to incorporate explicitly all of the fundamental properties for transporters at the plasma membrane and tonoplast, the salient features of osmolite metabolism, and the major controls of cytosolic-free Ca2+ concentration and pH. The library engenders a structured approach to tier and interrelate computational elements, and the OnGuard software allows ready access to parameters and equations ‘on the fly’ while enabling the network of components within each model to interact computationally. We show that an OnGuard model readily achieves stability in a set of physiologically sensible baseline or Reference States; we also show the robustness of these Reference States in adjusting to changes in environmental parameters and the activities of major groups of transporters both at the tonoplast and plasma membrane. The following article addresses the predictive power of the OnGuard model to generate unexpected and counterintuitive outputs. PMID:22635116

  3. Stomatal Function Requires Pectin De-methyl-esterification of the Guard Cell Wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amsbury, Sam; Hunt, Lee; Elhaddad, Nagat

    Stomatal opening and closure depends on changes in turgor pressure acting within guard cells to alter cell shape. The extent of these shape changes is limited by the mechanical properties of the cells, which will be largely dependent on the structure of the cell walls. Although it has long been observed that guard cells are anisotropic due to differential thickening and the orientation of cellulose microfibrils, our understanding of the composition of the cell wall that allows them to undergo repeated swelling and deflation remains surprisingly poor. Here, we show that the walls of guard cells are rich in un-esterified pectins.more » We identify a pectin methylesterase gene, PME6, which is highly expressed in guard cells and required for stomatal function. pme6-1 mutant guard cells have walls enriched in methyl-esterified pectin and show a decreased dynamic range in response to triggers of stomatal opening/closure, including elevated osmoticum, suggesting that abrogation of stomatal function reflects a mechanical change in the guard cell wall. Altered stomatal function leads to increased conductance and evaporative cooling, as well as decreased plant growth. The growth defect of the  pme6-1 mutant is rescued by maintaining the plants in elevated CO 2, substantiating gas exchange analyses, indicating that the mutant stomata can bestow an improved assimilation rate. Restoration of PME6 rescues guard cell wall pectin methyl-esterification status, stomatal function, and plant growth. Our results establish a link between gene expression in guard cells and their cell wall properties, with a corresponding effect on stomatal function and plant physiology.« less

  4. Stomatal Function Requires Pectin De-methyl-esterification of the Guard Cell Wall.

    PubMed

    Amsbury, Sam; Hunt, Lee; Elhaddad, Nagat; Baillie, Alice; Lundgren, Marjorie; Verhertbruggen, Yves; Scheller, Henrik V; Knox, J Paul; Fleming, Andrew J; Gray, Julie E

    2016-11-07

    Stomatal opening and closure depends on changes in turgor pressure acting within guard cells to alter cell shape [1]. The extent of these shape changes is limited by the mechanical properties of the cells, which will be largely dependent on the structure of the cell walls. Although it has long been observed that guard cells are anisotropic due to differential thickening and the orientation of cellulose microfibrils [2], our understanding of the composition of the cell wall that allows them to undergo repeated swelling and deflation remains surprisingly poor. Here, we show that the walls of guard cells are rich in un-esterified pectins. We identify a pectin methylesterase gene, PME6, which is highly expressed in guard cells and required for stomatal function. pme6-1 mutant guard cells have walls enriched in methyl-esterified pectin and show a decreased dynamic range in response to triggers of stomatal opening/closure, including elevated osmoticum, suggesting that abrogation of stomatal function reflects a mechanical change in the guard cell wall. Altered stomatal function leads to increased conductance and evaporative cooling, as well as decreased plant growth. The growth defect of the pme6-1 mutant is rescued by maintaining the plants in elevated CO 2 , substantiating gas exchange analyses, indicating that the mutant stomata can bestow an improved assimilation rate. Restoration of PME6 rescues guard cell wall pectin methyl-esterification status, stomatal function, and plant growth. Our results establish a link between gene expression in guard cells and their cell wall properties, with a corresponding effect on stomatal function and plant physiology. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. The Most Cut-Resistant Neck Guard for Preventing Lacerations to the Neck

    PubMed Central

    Loyd, Andre M.; Berglund, Lawrence; Twardowski, Casey P.; Stuart, Michael B.; Smith, Aynsley M.; Gaz, Daniel V.; Krause, David A.; An, Kai-Nan; Stuart, Michael J.

    2017-01-01

    Objective To evaluate the effectiveness of a variety of neck guard brands when contacted by a sharpened hockey skate blade. Design Analytic experimental. Setting Laboratory. Participants Neck surrogate. Interventions Forty-six samples of 14 different types of neck guards were tested on a custom-made laceration machine using a neck surrogate. Closed-cell polyethylene foam was placed between the neck surrogate and the protective device. Main Outcome Measures The effectiveness of the neck guard was evaluated by observation of the foam after the simulated slicing action of the skate blade. Two sets of tests were performed on each device sample including low and high force. For low-force tests, initial compression loads of 100, 200, and 300 N were applied between the neck surrogate for each of 2 orientations of the blade at 45 and 90 degrees. For high-force tests, representing a more severe simulation, the applied load was increased to 600 N and a blade angle fixed at 45 degrees. All tests were performed at a blade speed of 5 m/s. Results Only 1 product, the Bauer N7 Nectech, failed during the 300-N compression tests. All of the neck guards failed during 600-N test condition except for the Skate Armor device and 1 of the 3 Reebok 11K devices. Conclusions A skate blade angle of 45 degrees increased the likelihood of a neck laceration compared with a skate blade angle of 90 degrees due to decreased contact area. Damage to the neck guard is not an indicator of the cut resistance of a neck guard. Neck protectors with Spectra fibers were the most cut resistant. Clinical Relevance The study provides data for the selection of neck guards and neck guard materials that can reduce lacerations to the neck. PMID:24949830

  6. 76 FR 6694 - Drawbridge Operation Regulation; Upper Mississippi River, Keokuk, IA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-08

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket Number USCG-2011-0029] Drawbridge Operation Regulation; Upper Mississippi River, Keokuk, IA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, Eighth Coast Guard District, has...

  7. 76 FR 19911 - Drawbridge Operation Regulations; Apponagansett River, Dartmouth, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-11

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-0203] Drawbridge Operation Regulations; Apponagansett River, Dartmouth, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a...

  8. 77 FR 25890 - Drawbridge Operation Regulations; Manchester Harbor, Manchester, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-02

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0344] Drawbridge Operation Regulations; Manchester Harbor, Manchester, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a...

  9. 75 FR 14609 - Commercial Fishing Industry Vessel Safety Advisory Committee; Vacancies

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2010-0163] Commercial Fishing... applications. SUMMARY: The Coast Guard seeks applications for membership on the Commercial Fishing Industry... Coast Guard on matters relating to the safe operation of commercial fishing industry vessels. DATES...

  10. Coast Guard : update on Marine Information for Safety and Law Enforcement System

    DOT National Transportation Integrated Search

    2001-10-01

    The Coast Guard is developing a web-based information system to replace an aging computer system that it uses to track safety and law-enforcement actions involving commercial and recreational vessels. In 1995 the Coast Guard awarded a contract to dev...

  11. 76 FR 7757 - Hull Identification Numbers for Recreational Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-11

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 181 [Docket No. USCG-2007-29236] Hull Identification Numbers for Recreational Vessels AGENCY: Coast Guard, DHS. ACTION: Follow-up to request for... expanded hull identification number (HIN). The Coast Guard's decision-making process included consideration...

  12. Coast Guard : challenges for addressing budget constraints : report to congressional requesters

    DOT National Transportation Integrated Search

    1997-05-01

    Deficit reduction efforts will create substantial pressure on the Coast : Guards budget. By fiscal year 2002, the Coast Guard is projected to have a : gap of as much as a $493 million between OMBs budget target and the : estimated cost of maint...

  13. 33 CFR 165.2020 - Enforcement authority.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Enforcement authority. 165.2020 Section 165.2020 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Vessels § 165.2020 Enforcement authority. (a) Coast Guard. Any Coast Guard commissioned, warrant or petty...

  14. 33 CFR 165.2020 - Enforcement authority.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Enforcement authority. 165.2020 Section 165.2020 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Vessels § 165.2020 Enforcement authority. (a) Coast Guard. Any Coast Guard commissioned, warrant or petty...

  15. 33 CFR 165.2020 - Enforcement authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Enforcement authority. 165.2020 Section 165.2020 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Vessels § 165.2020 Enforcement authority. (a) Coast Guard. Any Coast Guard commissioned, warrant or petty...

  16. 33 CFR 165.2020 - Enforcement authority.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Enforcement authority. 165.2020 Section 165.2020 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Vessels § 165.2020 Enforcement authority. (a) Coast Guard. Any Coast Guard commissioned, warrant or petty...

  17. 33 CFR 165.2020 - Enforcement authority.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Enforcement authority. 165.2020 Section 165.2020 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Vessels § 165.2020 Enforcement authority. (a) Coast Guard. Any Coast Guard commissioned, warrant or petty...

  18. Coast guard : observations on the fiscal year 2010 budget and related performance and management challenges.

    DOT National Transportation Integrated Search

    2009-07-01

    The U.S. Coast Guard, a component : of the Department of Homeland : Security (DHS), conducts 11 : statutory missions that range from : marine safety to defense readiness. : To enhance mission performance, : the Coast Guard is implementing a : moderni...

  19. Individual, group, and environmental influences on helping behavior in a social carnivore

    USGS Publications Warehouse

    Ausband, David E.; Mitchell, Michael S.; Bassing, Sarah B.; Morehouse, Andrea T.; Smith, Douglas W.; Stahler, Daniel R.; Struthers, Jennifer

    2016-01-01

    Variation in group composition and environment can affect helping behavior in cooperative breeders. Understanding of how group size, traits of individuals within groups, food abundance, and predation risk simultaneously influence helping behavior is limited. We evaluated pup-guarding behavior in gray wolves (Canis lupus) to assess how differences in individuals, groups, and environment affect helping behavior. We used data from 92 GPS-collared wolves in North America (2001–2012) to estimate individual pup-guarding rates. Individuals in groups with low helper-to-pup ratios spent more time guarding young than those in groups with more helpers, an indication of load-lightening. Female helpers guarded more than male helpers, but this relationship weakened as pups grew. Subset analyses including data on helper age and wolf and prey density showed such factors did not significantly influence pup-guarding rates. We show that characteristics of individuals and groups have strong influences on pup-guarding behavior in gray wolves, but environmental factors such as food abundance and predation risk from conspecifics were not influential.

  20. Rice Stomatal Closure Requires Guard Cell Plasma Membrane ATP-Binding Cassette Transporter RCN1/OsABCG5.

    PubMed

    Matsuda, Shuichi; Takano, Sho; Sato, Moeko; Furukawa, Kaoru; Nagasawa, Hidetaka; Yoshikawa, Shoko; Kasuga, Jun; Tokuji, Yoshihiko; Yazaki, Kazufumi; Nakazono, Mikio; Takamure, Itsuro; Kato, Kiyoaki

    2016-03-07

    Water stress is one of the major environmental stresses that affect agricultural production worldwide. Water loss from plants occurs primarily through stomatal pores. Here, we report that an Oryza sativa half-size ATP-binding cassette (ABC) subfamily G protein, RCN1/OsABCG5, is involved in stomatal closure mediated by phytohormone abscisic acid (ABA) accumulation in guard cells. We found that the GFP-RCN1/OsABCG5-fusion protein was localized at the plasma membrane in guard cells. The percentage of guard cell pairs containing both ABA and GFP-RCN1/OsABCG5 increased after exogenous ABA treatment, whereas they were co-localized in guard cell pairs regardless of whether exogenous ABA was applied. ABA application resulted in a smaller increase in the percentage of guard cell pairs containing ABA in rcn1 mutant (A684P) and RCN1-RNAi than in wild-type plants. Furthermore, polyethylene glycol (drought stress)-inducible ABA accumulation in guard cells did not occur in rcn1 mutants. Stomata closure mediated by exogenous ABA application was strongly reduced in rcn1 mutants. Finally, rcn1 mutant plants had more rapid water loss from detached leaves than the wild-type plants. These results indicate that in response to drought stress, RCN1/OsABCG5 is involved in accumulation of ABA in guard cells, which is indispensable for stomatal closure. Copyright © 2016 The Author. Published by Elsevier Inc. All rights reserved.

  1. 32 CFR 112.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... urgency, importance, duration, location, or isolation, necessitates the absence of a member of the... Regular Army, Air Force, Navy, Marine Corps, or Coast Guard, and any member of a Reserve component of the Army, Air Force, Navy, Marine Corps, or Coast Guard (including the Army National Guard of the United...

  2. 76 FR 72308 - Drawbridge Operation Regulation; Upper Mississippi River, Dubuque, IA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-23

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-1039] Drawbridge Operation Regulation; Upper Mississippi River, Dubuque, IA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, Eighth Coast Guard District, has issued a...

  3. 76 FR 79066 - Drawbridge Operation Regulation; Upper Mississippi River, Clinton, IA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-21

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-1018] Drawbridge Operation Regulation; Upper Mississippi River, Clinton, IA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, Eighth Coast Guard District, has issued a...

  4. 75 FR 70817 - Drawbridge Operation Regulation; Upper Mississippi River, Dubuque, IA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-19

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2010-1039] Drawbridge Operation Regulation; Upper Mississippi River, Dubuque, IA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, Eighth Coast Guard District, has issued a...

  5. A Foundation to Prioritize Coast Guard AtoN Battery Disposal Sites for Characterization and Treatment

    DOT National Transportation Integrated Search

    1994-07-12

    The logical basis for prioritizing Coast Guard AtoN battery disposal sites for character : ization and treatment rests with values. The question is, "What does the Coast Guard : wish to achieve by cleaning up these sites?" Four separate meetings with...

  6. 75 FR 65567 - Drawbridge Operation Regulations; Mystic River, Charlestown, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-26

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2010-0924] Drawbridge Operation Regulations; Mystic River, Charlestown, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a temporary...

  7. 77 FR 6963 - Drawbridge Operation Regulations; Merrimack River, Amesbury, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-10

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0006] Drawbridge Operation Regulations; Merrimack River, Amesbury, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a temporary...

  8. 76 FR 3516 - Drawbridge Operation Regulations; Merrimack River, Newburyport and Salisbury, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-20

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2010-1134] Drawbridge Operation Regulations; Merrimack River, Newburyport and Salisbury, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  9. 76 FR 64009 - Drawbridge Operation Regulation; Apponagansett River, Dartmouth, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-17

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-0335] RIN 1625-AA09 Drawbridge Operation Regulation; Apponagansett River, Dartmouth, MA AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The Coast Guard has changed the drawbridge operation regulations that govern...

  10. 77 FR 65619 - Drawbridge Operation Regulations; Taunton River, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-30

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0895] Drawbridge Operation Regulations; Taunton River, MA AGENCY: Coast Guard, DHS. ACTION: Notice of deviation from drawbridge regulation; request for comments. SUMMARY: The Coast Guard has issued a temporary deviation from...

  11. 78 FR 15292 - Drawbridge Operation Regulations; West Bay, Osterville, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-11

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0053] Drawbridge Operation Regulations; West Bay, Osterville, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulation. SUMMARY: The Coast Guard has issued a temporary deviation from the regulation...

  12. 76 FR 37041 - Drawbridge Operation Regulation; Apponagansett River, Dartmouth, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-0335] RIN 1625-AA09 Drawbridge Operation Regulation; Apponagansett River, Dartmouth, MA AGENCY: Coast Guard, DHS. ACTION: Notice of proposed rulemaking. SUMMARY: The Coast Guard proposes to change the drawbridge...

  13. 76 FR 14804 - Drawbridge Operation Regulations; Bass River, Beverly, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-0149] Drawbridge Operation Regulations; Bass River, Beverly, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a temporary...

  14. 78 FR 35756 - Drawbridge Operation Regulations; Charles River, Boston, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-14

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [USCG-2013-0464] Drawbridge Operation Regulations; Charles River, Boston, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a temporary [[Page 35757...

  15. 75 FR 62469 - Drawbridge Operation Regulations; Charles River, Boston, MA, Maintenance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2010-0847] Drawbridge Operation Regulations; Charles River, Boston, MA, Maintenance AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a...

  16. 77 FR 35843 - Drawbridge Operation Regulation; Umpqua River, Reedsport, OR

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-15

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0534] Drawbridge Operation Regulation; Umpqua River, Reedsport, OR AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Coast Guard has issued a temporary deviation from the operating...

  17. 78 FR 18480 - Drawbridge Operation Regulations; Willamette River, Portland, OR

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-27

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0154] Drawbridge Operation Regulations; Willamette River, Portland, OR AGENCY: Coast Guard, DHS. ACTION: Notice of deviation from drawbridge regulation. SUMMARY: The Coast Guard has issued a temporary deviation from the...

  18. 30 CFR 77.400 - Mechanical equipment guards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mechanical equipment guards. 77.400 Section 77.400 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND... Safeguards for Mechanical Equipment § 77.400 Mechanical equipment guards. (a) Gears; sprockets; chains; drive...

  19. 77 FR 71369 - Updates to Voluntary Consensus Standards Incorporated by Reference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-30

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Chapter I 46 CFR Chapter I [Docket No. USCG-2012-0866] Updates to Voluntary Consensus Standards Incorporated by Reference AGENCY: Coast Guard, DHS. ACTION: Request for comments. SUMMARY: Many of the Coast Guard's regulations incorporate industry...

  20. Elimination of Coast Guard plan review for non-critical engineering systems and cargo barges

    DOT National Transportation Integrated Search

    1994-06-21

    The purpose of this Circular is to publish policy that provides for the elimination of Coast Guard review and approval of certain engineering system drawings for all vessels as well as structural drawings for Coast Guard inspected non-self propelled ...

  1. 78 FR 19725 - Merchant Mariner Medical Evaluation Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-02

    ... Examiners program, could be applied by the Coast Guard in making medical fitness determinations for issuance... Designated Aviation Medical Examiners program, could be applied by the Coast Guard in making medical fitness... ultimate determination of medical fitness rests with the Coast Guard, mariners may have any authorized...

  2. 30 CFR 77.510 - Resistors; location and guarding.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Resistors; location and guarding. 77.510 Section 77.510 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... COAL MINES Electrical Equipment-General § 77.510 Resistors; location and guarding. Resistors, heaters...

  3. 30 CFR 57.12034 - Guarding around lights.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guarding around lights. 57.12034 Section 57.12034 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12034 Guarding around lights. Portable extension lights, and other lights...

  4. 30 CFR 57.12034 - Guarding around lights.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Guarding around lights. 57.12034 Section 57.12034 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12034 Guarding around lights. Portable extension lights, and other lights...

  5. 30 CFR 57.12034 - Guarding around lights.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Guarding around lights. 57.12034 Section 57.12034 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12034 Guarding around lights. Portable extension lights, and other lights...

  6. 30 CFR 57.12034 - Guarding around lights.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Guarding around lights. 57.12034 Section 57.12034 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12034 Guarding around lights. Portable extension lights, and other lights...

  7. 30 CFR 57.12034 - Guarding around lights.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Guarding around lights. 57.12034 Section 57.12034 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12034 Guarding around lights. Portable extension lights, and other lights...

  8. 30 CFR 77.1011 - Drill holes; guarding.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Drill holes; guarding. 77.1011 Section 77.1011 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Control § 77.1011 Drill holes; guarding. Drill holes large enough to constitute a hazard shall be covered...

  9. 30 CFR 57.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Covering or guarding drill holes. 57.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface Only § 57.7013 Covering or guarding drill holes. Drill holes...

  10. 29 CFR 1917.151 - Machine guarding.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... restarting upon restoration of power. (7) The power supply to machines shall be turned off, locked out, and... contact with moving parts. (2) Belt, rope and chain drives shall be guarded to prevent employees from coming into contact with moving parts. (3) Gears, sprockets and chains shall be guarded to prevent...

  11. 29 CFR 1917.151 - Machine guarding.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... restarting upon restoration of power. (7) The power supply to machines shall be turned off, locked out, and... contact with moving parts. (2) Belt, rope and chain drives shall be guarded to prevent employees from coming into contact with moving parts. (3) Gears, sprockets and chains shall be guarded to prevent...

  12. 29 CFR 1917.151 - Machine guarding.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... restarting upon restoration of power. (7) The power supply to machines shall be turned off, locked out, and... contact with moving parts. (2) Belt, rope and chain drives shall be guarded to prevent employees from coming into contact with moving parts. (3) Gears, sprockets and chains shall be guarded to prevent...

  13. 78 FR 76750 - Drawbridge Operation Regulation; Upper Mississippi River, Clinton, IA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-19

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-1008] Drawbridge Operation Regulation; Upper Mississippi River, Clinton, IA AGENCY: Coast Guard, DHS. ACTION: Notice of deviation from drawbridge regulations. SUMMARY: The Coast Guard has issued a temporary deviation from the...

  14. 77 FR 69761 - Drawbridge Operation Regulation; Upper Mississippi River, Clinton, IA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-21

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0995] Drawbridge Operation Regulation; Upper Mississippi River, Clinton, IA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Coast Guard has issued a temporary deviation from the...

  15. 78 FR 72022 - Drawbridge Operation Regulation; Upper Mississippi River, Dubuque, IA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-02

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0964] Drawbridge Operation Regulation; Upper Mississippi River, Dubuque, IA AGENCY: Coast Guard, DHS. ACTION: Notice of deviation from drawbridge regulation. SUMMARY: The Coast Guard has issued a temporary deviation from the...

  16. 77 FR 69759 - Drawbridge Operation Regulation; Upper Mississippi River, Dubuque, IA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-21

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-1002] Drawbridge Operation Regulation; Upper Mississippi River, Dubuque, IA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Coast Guard has issued a temporary deviation from the...

  17. 78 FR 56837 - 2012 Liquid Chemical Categorization Updates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-16

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 46 CFR Parts 30, 150, and 153 [Docket No. USCG-2013-0423] RIN 1625-AB94 2012 Liquid Chemical Categorization Updates AGENCY: Coast Guard, DHS. ACTION: Interim rule; delay of effective date. SUMMARY: The Coast Guard is delaying the effective date of this...

  18. 75 FR 1704 - Federal Civil Penalties Inflation Adjustment Act-2009 Implementation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-13

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 27 [Docket No. USCG-2009-0891] RIN 1625-AB40 Federal Civil Penalties Inflation Adjustment Act--2009 Implementation AGENCY: Coast Guard, DHS. ACTION: Final rule; correction. SUMMARY: The Coast Guard is correcting a final rule that appeared in the...

  19. 78 FR 33774 - Ballast Water Management Reporting and Recordkeeping

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-05

    ...-AB68 Ballast Water Management Reporting and Recordkeeping AGENCY: Coast Guard, DHS. ACTION: Notice of proposed rulemaking. SUMMARY: The Coast Guard proposes to amend its existing ballast water management (BWM... annual report of their BWM practices. The Coast Guard also proposes to update the current ballast water...

  20. 78 FR 4855 - Random Drug Testing Rate for Covered Crewmembers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-23

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2009-0973] Random Drug Testing Rate for Covered Crewmembers AGENCY: Coast Guard, DHS. ACTION: Notice of minimum random drug testing rate. SUMMARY: The Coast Guard has set the calendar year 2013 minimum random drug testing rate at 25 percent of...

  1. 76 FR 79204 - Random Drug Testing Rate for Covered Crewmembers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-21

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2009-0973] Random Drug Testing Rate for Covered Crewmembers AGENCY: Coast Guard, DHS. ACTION: Notice of minimum random drug testing rate. SUMMARY: The Coast Guard has set the calendar year 2012 minimum random drug testing rate at 50 percent of...

  2. 65. Receiving gold numbers on her designation as "Queen of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    65. Receiving gold numbers on her designation as "Queen of the Fleet," serving as the oldest Coast Guard Cutter in active service when U.S. Coast Guard Cutter Ingham was decommissioned on May 27, 1988. - U.S. Coast Guard Cutter FIR, Puget Sound Area, Seattle, King County, WA

  3. 78 FR 18849 - Drawbridge Operation Regulations; Saugus River, Saugus and Lynn, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-28

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0176] Drawbridge Operation Regulations; Saugus River, Saugus and Lynn, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Coast Guard has issued a temporary deviation from the...

  4. 77 FR 34797 - Drawbridge Operation Regulations; Chelsea River, Chelsea and East Boston, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-12

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [USCG-2012-0396] Drawbridge Operation Regulations; Chelsea River, Chelsea and East Boston, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a temporary...

  5. 76 FR 79065 - Drawbridge Operation Regulations; Annisquam River and Blynman Canal, Gloucester, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-21

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-1099] Drawbridge Operation Regulations; Annisquam River and Blynman Canal, Gloucester, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  6. 76 FR 45420 - Drawbridge Operation Regulations; Annisquam River and Blynman Canal, Gloucester, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-0617] Drawbridge Operation Regulations; Annisquam River and Blynman Canal, Gloucester, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  7. 78 FR 22423 - Drawbridge Operation Regulations; Taunton River, Fall River and Somerset, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-16

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0236] Drawbridge Operation Regulations; Taunton River, Fall River and Somerset, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulation. SUMMARY: The Coast Guard is issuing a temporary deviation...

  8. 78 FR 29646 - Drawbridge Operation Regulations; Merrimack River, Haverhill and West Newbury, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-21

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0356] Drawbridge Operation Regulations; Merrimack River, Haverhill and West Newbury, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  9. 77 FR 56115 - Drawbridge Operation Regulations; Fort Point Channel, Boston, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-12

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0815] Drawbridge Operation Regulations; Fort Point Channel, Boston, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a temporary...

  10. 75 FR 51938 - Drawbridge Operation Regulation; Taunton River, Fall River and Somerset, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-24

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2010-0234] RIN 1625-AA09 Drawbridge Operation Regulation; Taunton River, Fall River and Somerset, MA AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The Coast Guard has changed the drawbridge operation regulations...

  11. 77 FR 37317 - Drawbridge Operation Regulations; Merrimack River, Haverhill and West Newbury, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0517] Drawbridge Operation Regulations; Merrimack River, Haverhill and West Newbury, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  12. 77 FR 6012 - Drawbridge Operation Regulations; Annisquam River and Blynman Canal, Gloucester, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-07

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0034] Drawbridge Operation Regulations; Annisquam River and Blynman Canal, Gloucester, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  13. 76 FR 73510 - Drawbridge Operation Regulations; Saugus River, Lynn and Revere, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-29

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-1034] Drawbridge Operation Regulations; Saugus River, Lynn and Revere, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a...

  14. 78 FR 65874 - Drawbridge Operation Regulations; Mystic River, Charlestown and Everett, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-04

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0889] Drawbridge Operation Regulations; Mystic River, Charlestown and Everett, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a...

  15. 76 FR 14804 - Drawbridge Operation Regulations; Annisquam River and Blynman Canal, Gloucester, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-0150] Drawbridge Operation Regulations; Annisquam River and Blynman Canal, Gloucester, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  16. 76 FR 4817 - Drawbridge Operation Regulations; Chelsea River, Chelsea and East Boston, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-27

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-0009] Drawbridge Operation Regulations; Chelsea River, Chelsea and East Boston, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  17. 78 FR 48608 - Drawbridge Operation Regulations; Townsend Gut, Boothbay Harbor and Southport, ME

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-09

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0719] Drawbridge Operation Regulations; Townsend Gut, Boothbay Harbor and Southport, ME AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  18. 78 FR 23134 - Drawbridge Operation Regulations; Townsend Gut, Boothbay Harbor and Southport, ME

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-18

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0223] Drawbridge Operation Regulations; Townsend Gut, Boothbay Harbor and Southport, ME AGENCY: Coast Guard, DHS. ACTION: Notice of deviation from drawbridge regulation. SUMMARY: The Coast Guard is issuing a temporary deviation...

  19. 78 FR 31962 - Collection of Information Under Review by Office of Management and Budget

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-28

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2012-1066] Collection of Information... Labour Convention (MLC) Navigation and Vessel Inspection Circular (NVIC). The Coast Guard will publish a... Maritime Labour Convention, 2006. The Coast Guard plans to establish a voluntary inspection program for...

  20. 30 CFR 57.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Covering or guarding drill holes. 57.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface Only § 57.7013 Covering or guarding drill holes. Drill holes...

  1. 30 CFR 77.1011 - Drill holes; guarding.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Drill holes; guarding. 77.1011 Section 77.1011 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Control § 77.1011 Drill holes; guarding. Drill holes large enough to constitute a hazard shall be covered...

  2. 30 CFR 77.1011 - Drill holes; guarding.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Drill holes; guarding. 77.1011 Section 77.1011 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Control § 77.1011 Drill holes; guarding. Drill holes large enough to constitute a hazard shall be covered...

  3. 30 CFR 77.1011 - Drill holes; guarding.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Drill holes; guarding. 77.1011 Section 77.1011 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Control § 77.1011 Drill holes; guarding. Drill holes large enough to constitute a hazard shall be covered...

  4. 30 CFR 77.1011 - Drill holes; guarding.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Drill holes; guarding. 77.1011 Section 77.1011 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Control § 77.1011 Drill holes; guarding. Drill holes large enough to constitute a hazard shall be covered...

  5. 30 CFR 57.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Covering or guarding drill holes. 57.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface Only § 57.7013 Covering or guarding drill holes. Drill holes...

  6. 30 CFR 57.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Covering or guarding drill holes. 57.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface Only § 57.7013 Covering or guarding drill holes. Drill holes...

  7. 30 CFR 57.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Covering or guarding drill holes. 57.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface Only § 57.7013 Covering or guarding drill holes. Drill holes...

  8. 33 CFR 62.1 - Purpose.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM General § 62.1 Purpose. (a) The Coast Guard administers the U.S. Aids to Navigation System. The system consists of Federal aids to navigation operated by the Coast Guard, aids to...

  9. 33 CFR 62.1 - Purpose.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM General § 62.1 Purpose. (a) The Coast Guard administers the U.S. Aids to Navigation System. The system consists of Federal aids to navigation operated by the Coast Guard, aids to...

  10. 33 CFR 62.1 - Purpose.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM General § 62.1 Purpose. (a) The Coast Guard administers the U.S. Aids to Navigation System. The system consists of Federal aids to navigation operated by the Coast Guard, aids to...

  11. 33 CFR 62.1 - Purpose.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM General § 62.1 Purpose. (a) The Coast Guard administers the U.S. Aids to Navigation System. The system consists of Federal aids to navigation operated by the Coast Guard, aids to...

  12. 30 CFR 77.509 - Transformers; installation and guarding.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Transformers; installation and guarding. 77.509... COAL MINES Electrical Equipment-General § 77.509 Transformers; installation and guarding. (a) Transformers shall be of the totally enclosed type, or shall be placed at least 8 feet above the ground, or...

  13. 30 CFR 77.509 - Transformers; installation and guarding.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Transformers; installation and guarding. 77.509... COAL MINES Electrical Equipment-General § 77.509 Transformers; installation and guarding. (a) Transformers shall be of the totally enclosed type, or shall be placed at least 8 feet above the ground, or...

  14. 30 CFR 77.509 - Transformers; installation and guarding.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Transformers; installation and guarding. 77.509... COAL MINES Electrical Equipment-General § 77.509 Transformers; installation and guarding. (a) Transformers shall be of the totally enclosed type, or shall be placed at least 8 feet above the ground, or...

  15. 30 CFR 77.509 - Transformers; installation and guarding.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Transformers; installation and guarding. 77.509... COAL MINES Electrical Equipment-General § 77.509 Transformers; installation and guarding. (a) Transformers shall be of the totally enclosed type, or shall be placed at least 8 feet above the ground, or...

  16. 30 CFR 77.509 - Transformers; installation and guarding.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Transformers; installation and guarding. 77.509... COAL MINES Electrical Equipment-General § 77.509 Transformers; installation and guarding. (a) Transformers shall be of the totally enclosed type, or shall be placed at least 8 feet above the ground, or...

  17. 75 FR 8491 - Security Zones; Brazos River, Freeport, TX

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-25

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2009-0501] RIN 1625-AA87 Security Zones; Brazos River, Freeport, TX AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The Coast Guard has established four permanent security zones in the Brazos River in Freeport, Texas...

  18. 78 FR 34579 - Safety Zone, Atlantic Intracoastal Waterway; Wrightsville Beach, NC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-10

    ... Rulemaking A. Regulatory History and Information The Coast Guard published a notice of proposed rulemaking... small businesses, not-for-profit organizations that are independently owned and operated and are not... Guard received no comments from the Small Business Administration on this rule. The Coast Guard...

  19. 78 FR 40000 - Eighth Coast Guard District Annual Safety Zones; Riverfront Independence Festival Fireworks; Ohio...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-03

    ...-AA00 Eighth Coast Guard District Annual Safety Zones; Riverfront Independence Festival Fireworks; Ohio.... SUMMARY: The Coast Guard will enforce a Safety Zone for the Riverfront Independence Festival Fireworks on... navigable waters during the Riverfront Independence Festival Fireworks. During the enforcement period, in...

  20. United States Coast Guard: Officer Corps Military Professional Development Program

    DTIC Science & Technology

    2011-06-10

    captain relieved of command after viewing porn on computer,‖ 10 July 2010, http://www.thenewstribune.com/2010/07/ 10/1259108/portland-coast-guard...Coast Guard captain relieved of command after viewing porn on computer,‖ 10 July 2010. http://www.thenewstribune.com/2010/07/ 10/1259108/portland

  1. 29 CFR 1917.151 - Machine guarding.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... restarting upon restoration of power. (7) The power supply to machines shall be turned off, locked out, and... contact with moving parts. (2) Belt, rope and chain drives shall be guarded to prevent employees from coming into contact with moving parts. (3) Gears, sprockets and chains shall be guarded to prevent...

  2. 29 CFR 1917.151 - Machine guarding.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... restarting upon restoration of power. (7) The power supply to machines shall be turned off, locked out, and... contact with moving parts. (2) Belt, rope and chain drives shall be guarded to prevent employees from coming into contact with moving parts. (3) Gears, sprockets and chains shall be guarded to prevent...

  3. 76 FR 1448 - Random Drug Testing Rate for Covered Crewmembers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-10

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2009-0973] Random Drug Testing Rate for Covered Crewmembers AGENCY: Coast Guard, DHS. ACTION: Notice of minimum random drug testing rate. SUMMARY: The Coast Guard has set the calendar year 2011 minimum random drug testing rate at 50 percent of...

  4. 29 CFR 1917.112 - Guarding of edges.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Guarding of edges. 1917.112 Section 1917.112 Labor... (CONTINUED) MARINE TERMINALS Terminal Facilities § 1917.112 Guarding of edges. (a) Vehicle protection. (1... provided at the waterside edges of aprons and bulkheads, except where vehicles are prohibited. Curbs or...

  5. 33 CFR 62.1 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM General § 62.1 Purpose. (a) The Coast Guard administers the U.S. Aids to Navigation System. The system consists of Federal aids to navigation operated by the Coast Guard, aids to...

  6. 33 CFR 67.50-30 - Ninth Coast Guard District.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Ninth Coast Guard District. 67.50-30 Section 67.50-30 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District Regulations § 67...

  7. 33 CFR 67.50-30 - Ninth Coast Guard District.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Ninth Coast Guard District. 67.50-30 Section 67.50-30 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District Regulations § 67...

  8. 33 CFR 67.50-15 - Fifth Coast Guard District.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Fifth Coast Guard District. 67.50-15 Section 67.50-15 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District Regulations § 67...

  9. 33 CFR 67.50-5 - First Coast Guard District.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false First Coast Guard District. 67.50-5 Section 67.50-5 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District Regulations § 67...

  10. 33 CFR 67.50-15 - Fifth Coast Guard District.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Fifth Coast Guard District. 67.50-15 Section 67.50-15 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District Regulations § 67...

  11. 33 CFR 67.50-50 - Seventeenth Coast Guard District.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Seventeenth Coast Guard District. 67.50-50 Section 67.50-50 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District...

  12. 33 CFR 67.50-45 - Thirteenth Coast Guard District.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Thirteenth Coast Guard District. 67.50-45 Section 67.50-45 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District...

  13. 33 CFR 67.50-50 - Seventeenth Coast Guard District.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Seventeenth Coast Guard District. 67.50-50 Section 67.50-50 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District...

  14. 33 CFR 67.50-20 - Seventh Coast Guard District.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Seventh Coast Guard District. 67.50-20 Section 67.50-20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District Regulations...

  15. 33 CFR 67.50-20 - Seventh Coast Guard District.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Seventh Coast Guard District. 67.50-20 Section 67.50-20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District Regulations...

  16. 33 CFR 67.50-5 - First Coast Guard District.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false First Coast Guard District. 67.50-5 Section 67.50-5 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District Regulations § 67...

  17. 33 CFR 67.50-45 - Thirteenth Coast Guard District.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Thirteenth Coast Guard District. 67.50-45 Section 67.50-45 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES District...

  18. 77 FR 37807 - Regattas and Marine Parades; Great Lakes Annual Marine Events

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-25

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 100 [Docket No. USCG-2012-0572] Regattas and Marine Parades; Great Lakes Annual Marine Events AGENCY: Coast Guard, DHS. ACTION: Notice of enforcement of regulation. SUMMARY: The Coast Guard will enforce various special local regulations for annual...

  19. 5 CFR 315.610 - Noncompetitive appointment of certain National Guard technicians.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... National Guard technicians. 315.610 Section 315.610 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT... technicians. (a) An agency may appoint noncompetitively a National Guard technician who— (1) Was involuntarily... 3 years as a technician; (3) Meets the qualifications requirements of the job: and (4) Is appointed...

  20. 75 FR 26091 - Regattas and Marine Parades; Great Lakes Annual Marine Events

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 100 [Docket No. USCG-2010-0312] Regattas and Marine Parades; Great Lakes Annual Marine Events AGENCY: Coast Guard, DHS. ACTION: Notice of enforcement of regulation. SUMMARY: The Coast Guard will enforce the local regulations for annual regattas and...

  1. Photocopy of photograph (original in collection of U.S. Coast Guard ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of photograph (original in collection of U.S. Coast Guard Civil Engineering Unit Providence, Warwick, RI) photographer unknown, 1975 Aerial view directly above - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  2. Photocopy of photograph (original in collection of U.S. Coast Guard ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of photograph (original in collection of U.S. Coast Guard Civil Engineering Unit Providence, Warwick, RI) photographer unknown, 1977 Aerial view looking northeast - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  3. Guards, Galleries, Fortresses, and the Octoplex

    ERIC Educational Resources Information Center

    Michael, T. S.

    2011-01-01

    The art gallery problem asks for the maximum number of stationary guards required to protect the interior of a polygonal art gallery with "n" walls. This article explores solutions to this problem and several of its variants. In addition, some unsolved problems involving the guarding of geometric objects are presented.

  4. 75 FR 35651 - Safety Zone; San Francisco Chronicle Fireworks Display, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-23

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG 2010-0367] Safety Zone; San Francisco Chronicle Fireworks Display, San Francisco, CA AGENCY: Coast Guard, DHS. ACTION: Notice of enforcement of regulation. SUMMARY: The Coast Guard will enforce the Independence Day...

  5. Research Methods to Develop Measures of Effectiveness of the United States Coast Guard’s Vessel Inspection and Boarding Program. Decision Support for Utilizing Measures of Effectiveness - Volume III

    DTIC Science & Technology

    1995-05-01

    Eubank S.E. Albuquerque, NM 87123 Christopher Rodriguez Kevin Downer U.S. Coast Guard Research and Development Center 1082 Shennecossett Road Groton...standard, specifica )e n. ’OVVELOPj4 Commanding Officer United States Coast Guard Research & Development Center 1082 Shennecossett Road SGroton, CT...Work Unit No. (TRAIS) U.S. Coast Guard Sandia National Laboratories Research and Development Center 11. Contract or Grant No. 1515 Eubank SE 1082

  6. Transforming the Army National Guard Health Promotion Policy - Meeting the Challenges of a Fit to Fight Army National Guard in the 21st Century

    DTIC Science & Technology

    2006-05-22

    Health Home Page, available from http://www.pdhealth.mil; Internet; accessed 5 March 2006. 34Howard Berkes , “Health Care Gap Cited for Guard, Reserve...Veteran”, The Providence Journal, Intelligence Report, April 30, 2006, pg 14. 36Howard Berkes and Marisa Penaloza, “The Span of War, Guard, Reserve...Page, available from http://www.balancedscorecard.org/basics/bsc1.html; Internet; accessed 3 February 2006. Berkes , Howard, “Health Care Gap Cited

  7. Commission on the National Guard and Reserves: Transforming the National Guard and Reserves into a 21st-Century Operational Force

    DTIC Science & Technology

    2008-01-31

    13DecForesmanCNGRTestimonyFINAL%5B1%5D.pdf), p. 3. Representatives Skelton and Taylor at March 2006 hearing. COMMISSION ON THE NATIONAL GUARD AND RESERVES 57 CREATING...Anniversary,” CMH Pub 72-32 (U.S. Army Center of Military History, 1995), available at www.army.mil/cmh-pg/documents/mobpam.htm. 8 Abbott A. Brayton ...Services Committee Representative Gene Taylor , Co-Chair, House National Guard and Reserve Components Caucus Representative Steve Buyer, Co-Chair, House

  8. Preliminary Assessment Springfield Air National Guard Base, Ohio Air National Guard, Springfield-Beckley Municipal Airport, Springfield, Ohio and Blue Ash Air National Guard Station, Ohio Air National Guard, Cincinnati, Ohio

    DTIC Science & Technology

    1988-12-01

    called soapstone . The third member of the Niagaran Series, the Laurel Dolomite, is thinly bedded, bluish-gray in color, and approximately 5 to 9 feet...slopes of hills. This m formation has a total thickness of 250 feet, and includes beds of limestone, soft shale, clay, or soapstone . The shales...INTERBEDDED. IRON [mineral] - A heavy, magnetic , malleable and ductile, and chemically active mineral, the native metallic element Fe. JP-4 - A type

  9. Final Environmental Assessment for Temporary Aircraft Relocation to Maxwell Air Force Base 187th Fighter Wing Montgomery Regional Airport Montgomery, Alabama

    DTIC Science & Technology

    2012-06-01

    Compatible Use Zone AIRFA American Indian Religious Freedom Act ALANG Alabama Air National Guard ANG Air National Guard ALNHP Alabama Natural Heritage...2012 1-3 1.3 LOCATION AND MISSION OF THE 187 FW AT MONTGOMERY REGIONAL AIRPORT The 187 FW of the Alabama Air National Guard ( ALANG ) is collocated...Army National Guard west of the primary parcel. South of Runway 10/28 is another 7-acre parcel for the Munitions Storage Area. ALANG also possesses

  10. 52. Photocopy of Outboard Profile, Booklet of General Plans, U.S.C.G.C. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    52. Photocopy of Outboard Profile, Booklet of General Plans, U.S.C.G.C. White Heath, WLM-545. U.S. Coast Guard Naval Engineering Department. U.S.C.G. Headquarters, Washington, D.C. Coast Guard Headquarters Drawing No. 540-WAGL-0103-019 C. sheet 2 of 7, dated May 1967; revised June 1971, December 1976, and April 1989. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  11. 57. Photocopy of Hold, Booklet of General Plans, U.S.C.G.C. White ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    57. Photocopy of Hold, Booklet of General Plans, U.S.C.G.C. White Heath, WLM-545. U.S. Coast Guard Naval Engineering Department, U.S.C.G. Headquarters, Washington, D.C. Coast Guard Headquarters Drawing No. 540-WAGL-0103-019 C. sheet 7 of 7, dated May 1967; revised June 1971, December 1976, and April 1989. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  12. 51. Photocopy of Title Sheet, Booklet of General Plans, U.S.C.G.C ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. Photocopy of Title Sheet, Booklet of General Plans, U.S.C.G.C White Heath, WLM-545, U.S. Coast Guard Naval Engineering Department, U.S.C.G. Headquarters, Washington, D.C. Coast Guard Headquarters Drawing No. 540-WAGL-0103-019 C. sheet 1 of 7, dated May 1967; revised June 1971, December 1976, and April 1989. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  13. 54. Photocopy of Top of Pilot House, Booklet of General ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    54. Photocopy of Top of Pilot House, Booklet of General Plans, U.S.C.G.C. White Heath, WLM-545. U.S. Coast Guard Naval Engineering Department, U.S.C.G. Headquarters, Washington, D.C. Coast Guard Headquarters Drawing No. 540-WAGL-0103-019 C. sheet 4 of 7, dated May 1967; revised June 1971, December 1976, and April 1989. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  14. 53. Photocopy of Inboard Profile, Booklet of General Plans, U.S.C.G.C. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    53. Photocopy of Inboard Profile, Booklet of General Plans, U.S.C.G.C. White Heath, WLM-545. U.S. Coast Guard Naval Engineering Department. U.S.C.G. Headquarters, Washington, D.C. Coast Guard Headquarters Drawing No. 540-WAGL-0103-019 C. sheet 3 of 7, dated May 1967; revised June 1971, December 1976, and April 1989. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  15. 55. Photocopy of Fcsle & Upper Deck, Booklet of General ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    55. Photocopy of Fcsle & Upper Deck, Booklet of General Plans, U.S.C.G.C. White Heath, WLM-545. U.S. Coast Guard Naval Engineering Department, U.S.C.G. Headquarters, Washington, D.C. Coast Guard Headquarters Drawing No. 540-WAGL-0103-019 C. sheet 5 of 7, dated May 1967; revised June 1971, December 1976, and April 1989. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  16. 56. Photocopy of Main Deck, Booklet of General Plans, U.S.C.G.C. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    56. Photocopy of Main Deck, Booklet of General Plans, U.S.C.G.C. White Heath WLM-545. U.S. Coast Guard Naval Engineering Department, U.S.C.G. Headquarters, Washington, D.C. Coast Guard Headquarters Drawing No. 540-WAGL-0103-019 C. sheet 6 of 7, dated May 1967; revised June 1971, December 1976, and April 1989. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  17. Common and unique elements of the ABA-regulated transcriptome of Arabidopsis guard cells

    PubMed Central

    2011-01-01

    Background In the presence of drought and other desiccating stresses, plants synthesize and redistribute the phytohormone abscisic acid (ABA). ABA promotes plant water conservation by acting on specialized cells in the leaf epidermis, guard cells, which border and regulate the apertures of stomatal pores through which transpirational water loss occurs. Following ABA exposure, solute uptake into guard cells is rapidly inhibited and solute loss is promoted, resulting in inhibition of stomatal opening and promotion of stomatal closure, with consequent plant water conservation. There is a wealth of information on the guard cell signaling mechanisms underlying these rapid ABA responses. To investigate ABA regulation of gene expression in guard cells in a systematic genome-wide manner, we analyzed data from global transcriptomes of guard cells generated with Affymetrix ATH1 microarrays, and compared these results to ABA regulation of gene expression in leaves and other tissues. Results The 1173 ABA-regulated genes of guard cells identified by our study share significant overlap with ABA-regulated genes of other tissues, and are associated with well-defined ABA-related promoter motifs such as ABREs and DREs. However, we also computationally identified a unique cis-acting motif, GTCGG, associated with ABA-induction of gene expression specifically in guard cells. In addition, approximately 300 genes showing ABA-regulation unique to this cell type were newly uncovered by our study. Within the ABA-regulated gene set of guard cells, we found that many of the genes known to encode ion transporters associated with stomatal opening are down-regulated by ABA, providing one mechanism for long-term maintenance of stomatal closure during drought. We also found examples of both negative and positive feedback in the transcriptional regulation by ABA of known ABA-signaling genes, particularly with regard to the PYR/PYL/RCAR class of soluble ABA receptors and their downstream targets, the type 2C protein phosphatases. Our data also provide evidence for cross-talk at the transcriptional level between ABA and another hormonal inhibitor of stomatal opening, methyl jasmonate. Conclusions Our results engender new insights into the basic cell biology of guard cells, reveal common and unique elements of ABA-regulation of gene expression in guard cells, and set the stage for targeted biotechnological manipulations to improve plant water use efficiency. PMID:21554708

  18. The deepwater horizon oil spill coast guard cohort study: A cross-sectional study of acute respiratory health symptoms.

    PubMed

    Alexander, Melannie; Engel, Lawrence S; Olaiya, Nathan; Wang, Li; Barrett, John; Weems, Laura; Schwartz, Erica G; Rusiecki, Jennifer A

    2018-04-01

    Over 8500 United States Coast Guard (USCG) personnel were deployed in response to the Deepwater Horizon (DWH) oil spill; however, human respiratory effects as a result of spill-related exposures are relatively unknown. USCG personnel who responded to the DWH oil spill were queried via survey on exposures to crude oil and oil dispersant, and acute respiratory symptoms experienced during deployment. Adjusted log binomial regressions were used to calculate prevalence ratios (PRs) and 95% confidence intervals (CI), investigating the associations between oil spill exposures and respiratory symptoms. 4855 USCG personnel completed the survey. More than half (54.6%) and almost one-fourth (22.0%) of responders were exposed to crude oil and oil dispersants, respectively. Coughing was the most prevalent symptom (19.4%), followed by shortness of breath (5.5%), and wheezing (3.6%). Adjusted analyses showed an exposure-response relationship between increasing deployment duration and likelihood of coughing, shortness of breath, and wheezing in the pre-capping period. A similar pattern was observed in the post-capping period for coughing and wheezing. Adjusted analyses revealed increased PRs for coughing (PR=1.92), shortness of breath (PR=2.60), and wheezing (PR=2.68) for any oil exposure. Increasing frequency of inhalation of oil was associated with increased likelihood of all three respiratory symptoms. A similar pattern was observed for contact with oil dispersants for coughing and shortness of breath. The combination of both oil and oil dispersants presented associations that were much greater in magnitude than oil alone for coughing (PR=2.72), shortness of breath (PR=4.65), and wheezing (PR=5.06). Results from the present study suggested strong relationships between oil and oil dispersant exposures and acute respiratory symptoms among disaster responders. Future prospective studies will be needed to confirm these findings. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Specific recognition of reproductive parasite workers by nest-entrance guards in the bumble bee Bombus terrestris.

    PubMed

    Blacher, Pierre; Boreggio, Laurie; Leroy, Chloé; Devienne, Paul; Châline, Nicolas; Chameron, Stéphane

    2013-12-10

    The impact of social parasites on their hosts' fitness is a strong selective pressure that can lead to the evolution of adapted defence strategies. Guarding the nest to prevent the intrusion of parasites is a widespread response of host species. If absolute rejection of strangers provides the best protection against parasites, more fine-tuned strategies can prove more adaptive. Guarding is indeed costly and not all strangers constitute a real threat. That is particularly true for worker reproductive parasitism in social insects since only a fraction of non-nestmate visitors, the fertile ones, can readily engage in parasitic reproduction. Guards should thus be more restrictive towards fertile than sterile non-nestmate workers. We here tested this hypothesis by examining the reaction of nest-entrance guards towards nestmate and non-nestmate workers with varying fertility levels in the bumble bee Bombus terrestris. Because social recognition in social insects mainly relies on cuticular lipids (CLs), chemical analysis was also conducted to examine whether workers' CLs could convey the relevant information upon which guards could base their decision. We thus aimed to determine whether an adapted defensive strategy to worker reproductive parasitism has evolved in B. terrestris colonies. Chemical analysis revealed that the cuticular chemical profiles of workers encode information about both their colony membership and their current fertility, therefore providing potential recognition cues for a suitable adjustment of the guards' defensive decisions. We found that guards were similarly tolerant towards sterile non-nestmate workers than towards nestmate workers. However, as predicted, guards responded more aggressively towards fertile non-nestmates. Our results show that B. terrestris guards discriminate non-nestmates that differ in their reproductive potential and respond more strongly to the individuals that are a greatest threat for the colony. Cuticular hydrocarbons are the probable cues underlying the specific recognition of reproductive parasites, with the specific profile of highly fertile bees eliciting the agonistic response when combined with non-colony membership information. Our study therefore provides a first piece of empirical evidence supporting the hypothesis that an adapted defensive strategy against worker reproductive parasitism exists in B. terrestris colonies.

  20. 30 CFR 56.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Covering or guarding drill holes. 56.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7013 Covering or guarding drill holes. Drill holes large enough to...

  1. Bird guard

    DOEpatents

    Fairchild, Dana M [Armour, SD

    2010-03-02

    The bird guard provides a device to protect electrical insulators comprising a central shaft; a clamp attached to an end of the shaft to secure the device to a transmission tower; a top and bottom cover to shield transmission tower insulators; and bearings to allow the guard to rotate in order to frighten birds away from the insulators.

  2. 77 FR 47582 - Great Lakes Pilotage Rates-2013 Annual Review and Adjust; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-09

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 46 CFR Part 401 [Docket No. USCG-2012-0409] RIN 1625-AB89 Great Lakes Pilotage Rates--2013 Annual Review and Adjust; Correction AGENCY: Coast Guard, DHS. ACTION: Notice of proposed rulemaking; correction. SUMMARY: The Coast Guard published a Notice of...

  3. 75 FR 32351 - Drawbridge Operation Regulation; Taunton River, Fall River and Somerset, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2010-0234] RIN 1625-AA09 Drawbridge Operation Regulation; Taunton River, Fall River and Somerset, MA AGENCY: Coast Guard, DHS. ACTION: Notice of proposed rulemaking. SUMMARY: The Coast Guard proposes to change the drawbridge...

  4. 78 FR 59902 - Regulated Navigation Area; Special Buzzards Bay Vessel Regulation, Buzzards Bay, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-30

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2011-0322] RIN 1625-AA11 Regulated Navigation Area; Special Buzzards Bay Vessel Regulation, Buzzards Bay, MA AGENCY: Coast Guard, DHS. ACTION: Notice of extension of comment period. SUMMARY: The Coast Guard is extending the...

  5. 78 FR 31457 - Drawbridge Operation Regulation; Taunton River, Fall River and Somerset, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-24

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2013-0291] RIN 1625-AA09 Drawbridge Operation Regulation; Taunton River, Fall River and Somerset, MA AGENCY: Coast Guard, DHS. ACTION: Notice of proposed rulemaking. SUMMARY: The Coast Guard proposes to modify the operating...

  6. 30 CFR 56.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Covering or guarding drill holes. 56.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7013 Covering or guarding drill holes. Drill holes large enough to...

  7. 30 CFR 56.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Covering or guarding drill holes. 56.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7013 Covering or guarding drill holes. Drill holes large enough to...

  8. 30 CFR 56.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Covering or guarding drill holes. 56.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7013 Covering or guarding drill holes. Drill holes large enough to...

  9. 30 CFR 56.7013 - Covering or guarding drill holes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Covering or guarding drill holes. 56.7013... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7013 Covering or guarding drill holes. Drill holes large enough to...

  10. 46 CFR 64.37 - Valve and fitting guard.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Valve and fitting guard. 64.37 Section 64.37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND... be protected from mechanical damage by— (a) The tank; (b) A tank saddle; (c) The framework; or (d) A...

  11. 46 CFR 64.37 - Valve and fitting guard.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Valve and fitting guard. 64.37 Section 64.37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND... be protected from mechanical damage by— (a) The tank; (b) A tank saddle; (c) The framework; or (d) A...

  12. 46 CFR 64.37 - Valve and fitting guard.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Valve and fitting guard. 64.37 Section 64.37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND... be protected from mechanical damage by— (a) The tank; (b) A tank saddle; (c) The framework; or (d) A...

  13. 46 CFR 64.37 - Valve and fitting guard.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Valve and fitting guard. 64.37 Section 64.37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND... be protected from mechanical damage by— (a) The tank; (b) A tank saddle; (c) The framework; or (d) A...

  14. 46 CFR 64.37 - Valve and fitting guard.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Valve and fitting guard. 64.37 Section 64.37 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND... be protected from mechanical damage by— (a) The tank; (b) A tank saddle; (c) The framework; or (d) A...

  15. 40th Combat Aviation Brigade and USS Ponce conduct interoperability

    Science.gov Websites

    training exercise > National Guard > Guard News - The National Guard Skip to main content Major of the ARNG State Mission Sustainability Training ARNG Distributed Learning Program Training & ; Technology Battle Lab (T3BL) Civil Support Simulation Exercises Regional Training Site Maintenance Battle

  16. Systems Engineering of Coast Guard Aviator Training.

    ERIC Educational Resources Information Center

    Hall, Eugene R.; Caro, Paul W.

    This paper describes a total-program application of the systems engineering concept of the U.S. Coast Guard aviation training programs. The systems approach used treats all aspects of the training to produce the most cost-effective integration of academic, synthetic, and flight training for the production of graduate Coast Guard aviators. The…

  17. 49 CFR 850.3 - Relationship to Coast Guard marine investigation regulations and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Relationship to Coast Guard marine investigation regulations and procedures. 850.3 Section 850.3 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL TRANSPORTATION SAFETY BOARD COAST GUARD-NATIONAL TRANSPORTATION SAFETY BOARD MARINE CASUALTY INVESTIGATIONS § 850.3...

  18. 75 FR 18755 - Security Zone; Calcasieu River and Ship Channel, LA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-13

    ...-AA87 Security Zone; Calcasieu River and Ship Channel, LA AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The Coast Guard is disestablishing the permanent safety zone at Trunkline LNG in Lake Charles, LA and replacing it with a security zone with new boundaries. The Coast Guard is also establishing two...

  19. 47 CFR 27.601 - Authority and coordination requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement...) Frequency coordination.(1) A Guard Band licensee, or a spectrum lessee operating at 775-776 MHz and 805-806...

  20. 47 CFR 27.601 - Authority and coordination requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement...) Frequency coordination.(1) A Guard Band licensee, or a spectrum lessee operating at 775-776 MHz and 805-806...

  1. 47 CFR 27.601 - Authority and coordination requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement...) Frequency coordination.(1) A Guard Band licensee, or a spectrum lessee operating at 775-776 MHz and 805-806...

  2. 47 CFR 27.601 - Authority and coordination requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement...) Frequency coordination.(1) A Guard Band licensee, or a spectrum lessee operating at 775-776 MHz and 805-806...

  3. 47 CFR 27.601 - Authority and coordination requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement....2(b), a Guard Band licensee may allow a spectrum lessee, pursuant to a spectrum lease arrangement...) Frequency coordination.(1) A Guard Band licensee, or a spectrum lessee operating at 775-776 MHz and 805-806...

  4. 49 CFR 393.86 - Rear impact guards and rear end protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Rear impact guards and rear end protection. 393.86... AND ACCESSORIES NECESSARY FOR SAFE OPERATION Miscellaneous Parts and Accessories § 393.86 Rear impact... rear impact guard that meets the requirements of Federal Motor Vehicle Safety Standard No. 223 (49 CFR...

  5. 76 FR 28795 - Privacy Act of 1974; Department of Homeland Security United States Coast Guard-024 Auxiliary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-18

    ... 1974; Department of Homeland Security United States Coast Guard-024 Auxiliary Database System of... Security/United States Coast Guard-024 Auxiliary Database (AUXDATA) System of Records.'' This system of... titled, ``DHS/USCG-024 Auxiliary Database (AUXDATA) System of Records.'' The AUXDATA system is the USCG's...

  6. 76 FR 71581 - Collection of Information Under Review by Office of Management and Budget

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-18

    ...., Washington, DC 20503, attention Desk Officer for the Coast Guard. (3) Hand Delivery: To DMF address above... are received in a timely manner, mark the fax, attention Desk Officer for the Coast Guard. The DMF....S. Coast Guard, Assistant Commandant for Command, Control, Communications, Computers and Information...

  7. 75 FR 19414 - Collection of Information Under Review by Office of Management and Budget: OMB Control Number...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-14

    ... Street, NW., Washington, DC 20503, attention Desk Officer for the Coast Guard. (3) Fax. (a) To DMF, 202... the fax, attention Desk Officer for the Coast Guard. The DMF maintains the public docket for this... Guard, Acting Assistant Commandant for Command, Control, Communications, Computers and Information...

  8. 29 CFR 1910.23 - Guarding floor and wall openings and holes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Walking-Working Surfaces § 1910.23 Guarding... swinging gate or so offset that a person cannot walk directly into the opening. (3) Every hatchway and... accidentally walk shall be guarded by either: (i) A standard railing with standard toeboard on all exposed...

  9. 49 CFR 1520.15 - SSI disclosed by TSA or the Coast Guard.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY SECURITY RULES FOR ALL MODES OF TRANSPORTATION PROTECTION OF SENSITIVE SECURITY INFORMATION § 1520.15 SSI disclosed by TSA or the Coast Guard. (a) In... allegations contained in a legal enforcement action document issued by TSA or the Coast Guard. (2) Security...

  10. 34 CFR 685.204 - Deferment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... National Guard on full-time National Guard duty, as defined in 10 U.S.C. 101(d)(5) under a call to active... borrower is— (i) Serving on active duty during a war or other military operation or national emergency; or (ii) Performing qualifying National Guard duty during a war or other military operation or national...

  11. 77 FR 40541 - Safety Zone; Water Main Crossing; Choctawhatchee Bay; Santa Rosa Beach, FL

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-10

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket Number USCG-2012-0518] RIN 1625-AA00 Safety Zone; Water Main Crossing; Choctawhatchee Bay; Santa Rosa Beach, FL AGENCY: Coast Guard, DHS. ACTION: Notice of Proposed Rulemaking. SUMMARY: The Coast Guard proposes to establish a...

  12. 78 FR 48805 - Safety Zone; Sprucewold Cabbage Island Swim, Linekin Bay, Boothbay Harbor, ME

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-12

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2012-1057] Safety Zone; Sprucewold Cabbage Island Swim, Linekin Bay, Boothbay Harbor, ME AGENCY: Coast Guard, DHS. ACTION: Notice of enforcement of regulation. SUMMARY: The Coast Guard will enforce a safety zone in the Captain...

  13. 46 CFR 190.25-5 - Where rails required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Where rails required. 190.25-5 Section 190.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS CONSTRUCTION AND ARRANGEMENT Rails and Guards § 190.25-5 Where rails required. (a) All vessels shall have efficient guard rails...

  14. A&M. Guard house (TAN638), contextual view. Built in 1968. Camera ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Guard house (TAN-638), contextual view. Built in 1968. Camera faces south. Guard house controlled access to radioactive waste storage tanks beyond and to left of view. Date: February 4, 2003. INEEL negative no. HD-33-4-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  15. 14 CFR 29.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Ground clearance: tail rotor guard. 29.411 Section 29.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 29.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  16. 14 CFR 27.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Ground clearance: tail rotor guard. 27.411 Section 27.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 27.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  17. 14 CFR 27.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Ground clearance: tail rotor guard. 27.411 Section 27.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 27.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  18. 14 CFR 29.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Ground clearance: tail rotor guard. 29.411 Section 29.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 29.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  19. 77 FR 26229 - Meloy Channel, U.S. Coast Guard Base Miami Beach, FL; Restricted Area

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-03

    ....S. Coast Guard Base Miami Beach, FL; Restricted Area AGENCY: United States Army Corps of Engineers... the waters surrounding the U.S. Coast Guard Base Miami Beach, Florida (Base Miami Beach). Base Miami... corridors encompassing the waters immediately contiguous to Base Miami Beach. The amendment will also serve...

  20. 19 CFR 12.85 - Coast Guard boat and associated equipment safety standards.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Coast Guard boat and associated equipment safety... SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Safety Standards for Boats and Associated Equipment § 12.85 Coast Guard boat and associated equipment safety standards. (a) Applicability of...

  1. 19 CFR 12.85 - Coast Guard boat and associated equipment safety standards.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Coast Guard boat and associated equipment safety... SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Safety Standards for Boats and Associated Equipment § 12.85 Coast Guard boat and associated equipment safety standards. (a) Applicability of...

  2. 19 CFR 12.85 - Coast Guard boat and associated equipment safety standards.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Coast Guard boat and associated equipment safety... SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Safety Standards for Boats and Associated Equipment § 12.85 Coast Guard boat and associated equipment safety standards. (a) Applicability of...

  3. 19 CFR 12.85 - Coast Guard boat and associated equipment safety standards.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Coast Guard boat and associated equipment safety... SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Safety Standards for Boats and Associated Equipment § 12.85 Coast Guard boat and associated equipment safety standards. (a) Applicability of...

  4. 19 CFR 12.85 - Coast Guard boat and associated equipment safety standards.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Coast Guard boat and associated equipment safety... SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Safety Standards for Boats and Associated Equipment § 12.85 Coast Guard boat and associated equipment safety standards. (a) Applicability of...

  5. Photocopy of photograph (original in collection of U.S. Coast Guard ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of photograph (original in collection of U.S. Coast Guard Civil Engineering Unit Providence, Warwich, RI), photographer unknown, 1977 view south, showing western docking structure and ordnance wharf - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  6. 77 FR 31183 - Safety Zone, Temporary Change for Recurring Fireworks Display Within the Fifth Coast Guard...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-25

    ...-AA00 Safety Zone, Temporary Change for Recurring Fireworks Display Within the Fifth Coast Guard District, Pamlico River and Tar River; Washington, NC AGENCY: Coast Guard, DHS. ACTION: Temporary final... is intended to restrict vessel traffic in a portion of the Pamlico River and Tar River near...

  7. The Membrane Transport System of the Guard Cell and Its Integration for Stomatal Dynamics1[CC-BY

    PubMed Central

    2017-01-01

    Stomatal guard cells are widely recognized as the premier plant cell model for membrane transport, signaling, and homeostasis. This recognition is rooted in half a century of research into ion transport across the plasma and vacuolar membranes of guard cells that drive stomatal movements and the signaling mechanisms that regulate them. Stomatal guard cells surround pores in the epidermis of plant leaves, controlling the aperture of the pore to balance CO2 entry into the leaf for photosynthesis with water loss via transpiration. The position of guard cells in the epidermis is ideally suited for cellular and subcellular research, and their sensitivity to endogenous signals and environmental stimuli makes them a primary target for physiological studies. Stomata underpin the challenges of water availability and crop production that are expected to unfold over the next 20 to 30 years. A quantitative understanding of how ion transport is integrated and controlled is key to meeting these challenges and to engineering guard cells for improved water use efficiency and agricultural yields. PMID:28408539

  8. Multi-species consumer jams and the fall of guarded corals to crown-of-thorns seastar outbreaks

    PubMed Central

    Kayal, Mohsen; Ballard, Jane; Adjeroud, Mehdi

    2018-01-01

    Outbreaks of predatory crown-of-thorns seastars (COTS) can devastate coral reef ecosystems, yet some corals possess mutualistic guardian crabs that defend against COTS attacks. However, guarded corals do not always survive COTS outbreaks, with the ecological mechanisms sealing the fate of these corals during COTS infestations remaining unknown. In August 2008 in Moorea (17.539° S, 149.830° W), French Polynesia, an unusually dense multi-species aggregation of predators was observed feeding upon guarded corals following widespread coral decline due to COTS predation. Concurrent assaults from these amplified, mixed-species predator guilds likely overwhelm mutualistic crab defense, ultimately leading to the fall of guarded corals. Our observations indicate that guarded corals can sustain devastating COTS attacks for an extended duration, but eventually concede to intensifying assaults from diverse predators that aggregate in high numbers as alternative prey decays. The fall of guarded corals is therefore suggested to be ultimately driven by an indirect trophic cascade that leads to amplified attacks from diverse starving predators following prey decline, rather than COTS assaults alone. PMID:29487739

  9. The Membrane Transport System of the Guard Cell and Its Integration for Stomatal Dynamics.

    PubMed

    Jezek, Mareike; Blatt, Michael R

    2017-06-01

    Stomatal guard cells are widely recognized as the premier plant cell model for membrane transport, signaling, and homeostasis. This recognition is rooted in half a century of research into ion transport across the plasma and vacuolar membranes of guard cells that drive stomatal movements and the signaling mechanisms that regulate them. Stomatal guard cells surround pores in the epidermis of plant leaves, controlling the aperture of the pore to balance CO 2 entry into the leaf for photosynthesis with water loss via transpiration. The position of guard cells in the epidermis is ideally suited for cellular and subcellular research, and their sensitivity to endogenous signals and environmental stimuli makes them a primary target for physiological studies. Stomata underpin the challenges of water availability and crop production that are expected to unfold over the next 20 to 30 years. A quantitative understanding of how ion transport is integrated and controlled is key to meeting these challenges and to engineering guard cells for improved water use efficiency and agricultural yields. © 2017 The author(s). All Rights Reserved.

  10. Methods of Testing Thermal Insulation and Associated Test Apparatus

    NASA Technical Reports Server (NTRS)

    Fesmire, James E. (Inventor); Augustynowicz, Stanislaw D. (Inventor)

    2004-01-01

    The system and method for testing thermal insulation uses a cryostatic insulation tester having a vacuum chamber and a cold mass including a test chamber and upper and lower guard chambers adjacent thereto. The thermal insulation is positioned within the vacuum chamber and adjacent the cold mass. Cryogenic liquid is supplied to the test chamber, upper guard and lower guard to create a first gas layer in an upper portion of the lower guard chamber and a second gas layer in an upper portion of the test chamber. Temperature are sensed within the vacuum chamber to test the thermal insulation.

  11. Coast Guard Aircraft: Transfer of Fixed-Wing C-27J Aircraft Is Complex and Further Fleet Purchases Should Coincide with Study Results

    DTIC Science & Technology

    2015-03-01

    C-27J to the Coast Guard. This report assesses (1) the status of the transfer and risks the Coast Guard faces in fielding the transferred aircraft...had transferred 2 of the 14 C-27J aircraft it is receiving from the Air Force to its aircraft maintenance facility, with plans to field 14 fully...Coast Guard continues to receive these aircraft in the near term, the capability and cost of the Coast Guard’s fixed-wing fleet runs the risk of being

  12. Joint FAM/Line Management Assessment Report on LLNL Machine Guarding Safety Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Armstrong, J. J.

    2016-07-19

    The LLNL Safety Program for Machine Guarding is implemented to comply with requirements in the ES&H Manual Document 11.2, "Hazards-General and Miscellaneous," Section 13 Machine Guarding (Rev 18, issued Dec. 15, 2015). The primary goal of this LLNL Safety Program is to ensure that LLNL operations involving machine guarding are managed so that workers, equipment and government property are adequately protected. This means that all such operations are planned and approved using the Integrated Safety Management System to provide the most cost effective and safest means available to support the LLNL mission.

  13. Plant, cell, and molecular mechanisms of abscisic-acid regulation of stomatal apertures. In vivo phosphorylation of phosphoenolpyruvate carboxylase in guard cells of Vicia faba L. is enhanced by fusicoccin and suppressed by abscisic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Du, Z.; Aghoram, K.; Outlaw, W.H. Jr.

    Plants regulate water loss and CO{sub 2} gain by modulating the aperture sizes of stomata that penetrate the epidermis. Aperture size itself is increased by osmolyte accumulation and consequent turgor increase in the pair of guard cells that flank each stoma. Guard-cell phosphoenolpyruvate carboxylase, which catalyzes the regulated step leading to malate synthesis, is crucial for charge and pH maintenance during osmolyte accumulation. Regulation of this cytosolic enzyme by effectors is well documented, but additional regulation by posttranslational modification is predicted by the alteration of PEPC kinetics during stomatal opening. In this study, the authors have investigated whether this alterationmore » is associated with the phosphorylation status of this enzyme. Using sonicated epidermal peels (isolated guard cells) pre-loaded with {sub 32}PO{sub 4}, the authors induced stomatal opening and guard-cell malate accumulation by incubation with 5 {micro}M fusicoccin (FC). In corroboratory experiments, guard cells were incubated with 5 {micro}M fusicoccin (FC). In corroboratory experiments, guard cells were incubated with the FC antagonist, 10 {micro}M abscisic acid (ABA). The phosphorylation status of PEPC was assessed by immunoprecipitation, electrophoresis, immunoblotting, and autoradiography. PEPC was phosphorylated when stomata were stimulated to open, and phosphorylation was lessened by incubation with ABA.« less

  14. Mate guarding in the Seychelles warbler is energetically costly and adjusted to paternity risk.

    PubMed

    Komdeur, J

    2001-10-22

    Males may increase their fitness through extra-pair copulations (copulations outside the pair bond) that result in extra-pair fertilizations, but also risk lost paternity when they leave their own mate unguarded. The fitness costs of cuckoldry for Seychelles warblers (Acrocephalus sechellensis) are considerable because warblers have a single-egg clutch and, given the short breeding season, no time for a successful replacement clutch. Neighbouring males are the primary threat to a male's genetic paternity. Males minimize their loss of paternity by guarding their mates to prevent them from having extra-pair copulations during their fertile period. Here, I provide experimental evidence that mate-guarding behaviour is energetically costly and that the expression of this trade-off is adjusted to paternity risk (local male density). Free-living males that were induced to reduce mate guarding spent significantly more time foraging and gained significantly better body condition than control males. The larger the reduction in mate guarding, the more pronounced was the increase in foraging and body condition (accounting for food availability). An experimental increase in paternity risk resulted in an increase in mate-guarding intensity and a decrease in foraging and body condition, and vice versa. This is examined using both cross-sectional and longitudinal data. This study on the Seychelles warbler offers experimental evidence that mate guarding is energetically costly and adjusted to paternity risk.

  15. 75 FR 50952 - Safety Zone; Blue Angels at Kaneohe Bay Air Show, Oahu, HI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-18

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2010-0705] RIN 1625-AA00 Safety Zone; Blue Angels at Kaneohe Bay Air Show, Oahu, HI AGENCY: Coast Guard, DHS. ACTION: Notice of proposed rulemaking. SUMMARY: The Coast Guard proposes two temporary safety zones while the U.S...

  16. 77 FR 56549 - Safety Zone; Blue Angels at Kaneohe Bay Air Show, Oahu, HI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-13

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket Number USCG-2012-0739] RIN 1625-AA00 Safety Zone; Blue Angels at Kaneohe Bay Air Show, Oahu, HI AGENCY: Coast Guard, DHS. ACTION: Temporary final rule. SUMMARY: The Coast Guard is establishing a temporary safety zone while the U.S. Navy...

  17. A Guard Dog Perspective on the Role of Media.

    ERIC Educational Resources Information Center

    Donohue, George A.; And Others

    1995-01-01

    Offers a "guard dog" metaphor for the functioning of the mass media, suggesting that media perform as a sentry for groups having sufficient power and influence to create and control their own security systems. Delineates this perspective from others, and suggests several hypotheses that may be derived for testing the utility of the guard dog…

  18. 75 FR 20776 - Security Zone; Potomac River, Washington Channel, Washington, DC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    .... Coast Guard Commandant's Change of Command ceremony from 6 a.m. through 5 p.m. on May 25, 2010. Entry.... Basis and Purpose The Coast Guard will conduct a Change of Command ceremony at Fort McNair in Washington... the U.S. Coast Guard Commandant's Change of Command ceremony. Due to the catastrophic impact a...

  19. 78 FR 8027 - Safety Zone, Coast Guard Exercise Area, Hood Canal, Washington

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-05

    ... requests for public meeting. However, on November 4, 2012, pursuant to a request by the Port Gamble S.... However, the Coast Guard did meet with the Port Gamble S'Klallam Tribe at their request. In response to... that the Coast Guard did consult with the Port Gamble S'Klallam Tribe at their request during the...

  20. 77 FR 42649 - Safety Zone: Sea World San Diego Fireworks, Mission Bay; San Diego, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-20

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket Number USCG-2012-0497] RIN 1625-AA00 Safety Zone: Sea World San Diego Fireworks, Mission Bay; San Diego, CA AGENCY: Coast Guard, DHS. ACTION: Temporary final rule. SUMMARY: The Coast Guard is establishing a temporary safety zone on...

  1. Research on Building Education & Workforce Capacity in Systems Engineering

    DTIC Science & Technology

    2012-09-30

    Science Coast Guard Academy Chris Lund, Research Engineer USCG R&D center Civil Engineering Coast Guard Academy Scot T. Tripp, Program Manager USCG...74 researchers Coast Guard Academy Scot T. Tripp, Program Manager Internal institutional USCG R&D center... Woods Industry Lockheed Martin Aeronautics Company Defense contracted system development and analysis Stevens Tom Newby Industry Buro

  2. 33 CFR 140.101 - Inspection by Coast Guard marine inspectors or Bureau of Ocean Energy Management, Regulation and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Inspection by Coast Guard marine inspectors or Bureau of Ocean Energy Management, Regulation and Enforcement inspectors. 140.101 Section 140... CONTINENTAL SHELF ACTIVITIES GENERAL Inspections § 140.101 Inspection by Coast Guard marine inspectors or...

  3. 33 CFR 140.101 - Inspection by Coast Guard marine inspectors or Bureau of Ocean Energy Management, Regulation and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Inspection by Coast Guard marine inspectors or Bureau of Ocean Energy Management, Regulation and Enforcement inspectors. 140.101 Section 140... CONTINENTAL SHELF ACTIVITIES GENERAL Inspections § 140.101 Inspection by Coast Guard marine inspectors or...

  4. 33 CFR 140.101 - Inspection by Coast Guard marine inspectors or Bureau of Ocean Energy Management, Regulation and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Inspection by Coast Guard marine inspectors or Bureau of Ocean Energy Management, Regulation and Enforcement inspectors. 140.101 Section 140... CONTINENTAL SHELF ACTIVITIES GENERAL Inspections § 140.101 Inspection by Coast Guard marine inspectors or...

  5. 46 CFR 159.007-7 - Application for acceptance for production inspections and tests: Coast Guard action.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Application for acceptance for production inspections and tests: Coast Guard action. 159.007-7 Section 159.007-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection...

  6. 46 CFR 159.007-7 - Application for acceptance for production inspections and tests: Coast Guard action.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Application for acceptance for production inspections and tests: Coast Guard action. 159.007-7 Section 159.007-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection...

  7. 76 FR 20742 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-13

    ... price movements between 9:30 a.m. and 4 p.m. Eastern Standard Time (``EST''). Volatility Guard is... March 11, 2011, the Commission approved Rule 4753(c) (the ``Volatility Guard''), a volatility-based... six month pilot applied to the NASDAQ 100 Index securities.\\3\\ The Volatility Guard automatically...

  8. Defense.gov Special Report: Hispanic Heritage Month

    Science.gov Websites

    , practice and test their skills in STEM. Name: Coast Guard Lt. Cmdr. Luis Carmona Coast Guard Lt. Cmdr. Luis of the Coast Guard's College Student Pre-Commissioning Initiative program, leveraged his extensive to the U.S. Army Operational Test Command, Fort Hood, Texas, where he served as chief of the Combat

  9. 77 FR 37604 - Safety Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-22

    ...: The Coast Guard will enforce a 1,000 foot safety zone around the Berkeley Pier in position 37[deg]51... Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA AGENCY: Coast Guard, DHS. ACTION: Notice of enforcement of regulation. SUMMARY: The Coast Guard will enforce the safety zone for the Berkeley...

  10. 76 FR 1521 - Security Zone: Fleet Industrial Supply Center Pier, San Diego, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-11

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2010-0423] RIN 1625-AA87 Security Zone: Fleet Industrial Supply Center Pier, San Diego, CA AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The Coast Guard is removing a security zone on the navigable waters of San Diego...

  11. 75 FR 39552 - Collection of Information Under Review by Office of Management and Budget; OMB Control Number...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-09

    ...) To OIRA, 725 17th Street, NW., Washington, DC 20503, attention Desk Officer for the Coast Guard. (3... timely manner, mark the fax, attention Desk Officer for the Coast Guard. The DMF maintains the public..., U.S. Coast Guard, Acting Assistant Commandant for Command, Control, Communications, Computers and...

  12. 75 FR 31459 - Collection of Information Under Review by Office of Management and Budget: OMB Control Number...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-03

    ...) To OIRA, 725 17th Street, NW., Washington, DC 20503, attention Desk Officer for the Coast Guard. (3... timely manner, mark the fax, attention Desk Officer for the Coast Guard. The DMF maintains the public..., U.S. Coast Guard, Acting Assistant Commandant for Command, Control, Communications, Computers and...

  13. 77 FR 9949 - Collection of Information Under Review by Office of Management and Budget

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-21

    ... Street NW., Washington, DC 20503, attention Desk Officer for the Coast Guard. (3) Hand Delivery: To DMF... comments are received in a timely manner, mark the fax, attention Desk Officer for the Coast Guard. The DMF.... R.E. Day, Rear Admiral, U.S. Coast Guard, Assistant Commandant for Command, Control, Communications...

  14. 78 FR 74156 - Collection of Information Under Review by Office of Management and Budget

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-10

    ..., attention Desk Officer for the Coast Guard. (3) Hand Delivery: To DMF address above, between 9 a.m. and 5 p... timely manner, mark the fax, attention Desk Officer for the Coast Guard. The DMF maintains the public.... Day, Rear Admiral, U.S. Coast Guard, Assistant Commandant for Command, Control, Communications...

  15. 77 FR 73334 - Adding International Energy Efficiency (IEE) Certificate to List of Certificates a Recognized...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-10

    ... Classification Society May Issue AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The Coast Guard is...) Certificate to the list of certificates that a recognized classification society may issue on behalf of the... January 1, 2013. This rule will enable recognized classification societies to apply to the Coast Guard to...

  16. 77 FR 37318 - Eighth Coast Guard District Annual Safety Zones; Sound of Independence; Santa Rosa Sound; Fort...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ...-AA00 Eighth Coast Guard District Annual Safety Zones; Sound of Independence; Santa Rosa Sound; Fort... Coast Guard will enforce a Safety Zone for the Sound of Independence event in the Santa Rosa Sound, Fort... during the Sound of Independence. During the enforcement period, entry into, transiting or anchoring in...

  17. 48 CFR 31.205-6 - Compensation for personal services.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... following: (A) To all executive agencies, other than DoD, NASA and the Coast Guard, for contracts awarded before, on, or after December 31, 2011; (B) To DoD, NASA, and the Coast Guard for contracts awarded... limit. (i) Applicability. This paragraph (p)(2) applies to DoD, NASA, and the Coast Guard for contracts...

  18. 48 CFR 31.205-6 - Compensation for personal services.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the following: (A) To all executive agencies, other than DoD, NASA, and the Coast Guard, for contracts awarded before June 24, 2014; (B) To DoD, NASA, and the Coast Guard for contracts awarded before December... paragraph (p)(2) applies to DOD, NASA, and the Coast Guard for contracts awarded on or after December 31...

  19. 22. AERIAL VIEW TO NORTH OF ENTIRE COAST GUARD AIR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. AERIAL VIEW TO NORTH OF ENTIRE COAST GUARD AIR STATION SAN FRANCISCO, SHOWING BUILDING H AT LEFT AND BUILDING F AT UPPER LEFT. 30X24 inch black and white silver gelatin print. Photographers unknown. Date unknown. - U.S. Coast Guard Air Station San Francisco, Warehouse, 1020 North Access Road, San Francisco, San Francisco County, CA

  20. 76 FR 3014 - Security Zone; Protection of Military Cargo, Captain of the Port Zone Puget Sound, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... Coast Guard will enforce the Blair Waterway security zone in Commencement Bay, WA for protection of... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2011-0015] Security Zone; Protection of Military Cargo, Captain of the Port Zone Puget Sound, WA AGENCY: Coast Guard, DHS...

  1. 64. Photocopy of Buoy Derrick Arrangement, WAGL 543 and WAGL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    64. Photocopy of Buoy Derrick Arrangement, WAGL 543 and WAGL 542. Puget Sound Naval Shipyard, Bremerton, Washington, Coast Guard Headquarters Drawing No. 540-WAGL-1701-20, dated April 1948. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA

  2. 76 FR 4706 - Self-Defense of Vessels of the United States

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-26

    ... view the comments and Coast Guard Port Security Advisory (PSA) 3-09, which provides guidance to the... guidance published by the Coast Guard in Port Security Advisory (PSA) 3-09 provide an adequate framework... regard to the use of force against pirates is currently provided in PSA 3-09. The Coast Guard seeks...

  3. Future leaders: Rwandan resolve « Coast Guard Compass

    Science.gov Websites

    Karama, an international cadet at the U.S. Coast Guard Academy, is from the African country of Rwanda , an international cadet at the U.S. Coast Guard Academy, is from the African country of Rwanda. U.S ; The Academy has several international cadets in attendance from countries spanning the globe. Bringing

  4. 77 FR 70452 - Mechanisms of Compliance With United States Citizenship Requirements for the Ownership of Vessels...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    ... Restricted Trades by Publicly Traded Companies AGENCY: Coast Guard, DHS. ACTION: Notice; response to comments... notice in the Federal Register seeking those comments and that information. The Coast Guard read the... inform industry and the public on how the Coast Guard plans to exercise its discretion in enforcing the...

  5. 33 CFR 173.81 - Coast Guard forms for numbering and casualty reporting.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....29(a) must be made on Form CG- 3920, Change of Address Notice. (4) Each notification required by... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Coast Guard forms for numbering... Issue of Certificate of Number § 173.81 Coast Guard forms for numbering and casualty reporting. (a) In a...

  6. 77 FR 42647 - Safety Zone: San Diego Symphony POPS Fireworks; San Diego, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-20

    ... 1625-AA00 Safety Zone: San Diego Symphony POPS Fireworks; San Diego, CA AGENCY: Coast Guard, DHS... waters of San Diego Bay in support of the San Diego Symphony POPS Fireworks. This safety zone is... David Varela, Waterways Management, U.S. Coast Guard Sector San Diego, Coast Guard; telephone 619-278...

  7. 77 FR 42652 - Meloy Channel, U.S. Coast Guard Base Miami Beach, FL; Restricted Area

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-20

    ....S. Coast Guard Base Miami Beach, FL; Restricted Area AGENCY: United States Army Corps of Engineers... Guard Base Miami Beach, Florida (Base Miami Beach). Base Miami Beach is composed of multiple U.S. Coast... contiguous to Base Miami Beach. The amendment will also serve to protect the general public from injury or...

  8. 75 FR 748 - Special Local Regulation for Marine Events; Recurring Marine Events in the Fifth Coast Guard...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-06

    ...-AA08 Special Local Regulation for Marine Events; Recurring Marine Events in the Fifth Coast Guard... recurring marine events within the Fifth Coast Guard District. These regulations make minor changes to the regulated areas of two permitted marine events listed in the table attached to the regulation. These special...

  9. 76 FR 10385 - Information Collection Request to Office of Management and Budget; OMB Control Number: 1625-0106

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-24

    ... Office of Management and Budget; OMB Control Number: 1625-0106 AGENCY: Coast Guard, DHS. ACTION: Sixty....S. Coast Guard intends to submit an Information Collection Request (ICR) to the Office of Management... Coast Guard docket number [USCG-2011-0087] to the Docket Management Facility (DMF) at the U.S...

  10. 49 CFR 393.86 - Rear impact guards and rear end protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 571.223) in effect at the time the vehicle was manufactured. When the rear impact guard is installed... (49 CFR 571.224) in effect at the time the vehicle was manufactured. The requirements of paragraph (a... extremity of the vehicle. (3) Guard height. The vertical distance between the bottom edge of the horizontal...

  11. 49 CFR 393.86 - Rear impact guards and rear end protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 571.223) in effect at the time the vehicle was manufactured. When the rear impact guard is installed... (49 CFR 571.224) in effect at the time the vehicle was manufactured. The requirements of paragraph (a... extremity of the vehicle. (3) Guard height. The vertical distance between the bottom edge of the horizontal...

  12. 49 CFR 393.86 - Rear impact guards and rear end protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 571.223) in effect at the time the vehicle was manufactured. When the rear impact guard is installed... (49 CFR 571.224) in effect at the time the vehicle was manufactured. The requirements of paragraph (a... extremity of the vehicle. (3) Guard height. The vertical distance between the bottom edge of the horizontal...

  13. 49 CFR 393.86 - Rear impact guards and rear end protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 571.223) in effect at the time the vehicle was manufactured. When the rear impact guard is installed... (49 CFR 571.224) in effect at the time the vehicle was manufactured. The requirements of paragraph (a... extremity of the vehicle. (3) Guard height. The vertical distance between the bottom edge of the horizontal...

  14. Photocopy of drawing (original drawing of Fire and Guard House ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Fire and Guard House with Communication Center in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1940 architectural drawings by Construction Division, Office of the Quartermaster General) ELEVATIONS AND SECTIONS - MacDill Air Force Base, Fire & Guard House, 2709 Florida Keys Avenue, Tampa, Hillsborough County, FL

  15. Photocopy of drawing (original drawing of Fire and Guard House ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Fire and Guard House with Communication Center in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1940 architectural drawings by Construction Division, Office of the Quartermaster General) EXTERIOR AND MISCELLANEOUS DETAILS - MacDill Air Force Base, Fire & Guard House, 2709 Florida Keys Avenue, Tampa, Hillsborough County, FL

  16. Photocopy of drawing (original drawing of Fire and Guard House ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Fire and Guard House with Communication Center in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1940 architectural drawings by Construction Division, Office of the Quartermaster General) FRONT ELEVATION DETAILS - MacDill Air Force Base, Fire & Guard House, 2709 Florida Keys Avenue, Tampa, Hillsborough County, FL

  17. Photocopy of drawing (original drawing of Fire and Guard House ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (original drawing of Fire and Guard House with Communication Center in possession of MacDill Air Force Base, Civil Engineering, Tampa, Florida; 1940 architectural drawings by Construction Division, Office of the Quartermaster General) CELL BLOCK DETAILS - MacDill Air Force Base, Fire & Guard House, 2709 Florida Keys Avenue, Tampa, Hillsborough County, FL

  18. Statistical organelle dissection of Arabidopsis guard cells using image database LIPS.

    PubMed

    Higaki, Takumi; Kutsuna, Natsumaro; Hosokawa, Yoichiroh; Akita, Kae; Ebine, Kazuo; Ueda, Takashi; Kondo, Noriaki; Hasezawa, Seiichiro

    2012-01-01

    To comprehensively grasp cell biological events in plant stomatal movement, we have captured microscopic images of guard cells with various organelles markers. The 28,530 serial optical sections of 930 pairs of Arabidopsis guard cells have been released as a new image database, named Live Images of Plant Stomata (LIPS). We visualized the average organellar distributions in guard cells using probabilistic mapping and image clustering techniques. The results indicated that actin microfilaments and endoplasmic reticulum (ER) are mainly localized to the dorsal side and connection regions of guard cells. Subtractive images of open and closed stomata showed distribution changes in intracellular structures, including the ER, during stomatal movement. Time-lapse imaging showed that similar ER distribution changes occurred during stomatal opening induced by light irradiation or femtosecond laser shots on neighboring epidermal cells, indicating that our image analysis approach has identified a novel ER relocation in stomatal opening.

  19. Stomatal responses to CO/sub 2/ in Paphiopedilum and Phragmipedium: role of the guard cell chloroplast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Assmann, S.M.; Zeiger, E.

    A role of the guard cell chloroplasts in the CO/sub 2/ response of stomata was investigated through a comparison of the leaf gas exchange characteristics of two closely related orchids: Paphiopedilum harrisianum, which lacks guard cell chloroplasts and Phragmipedium longifolium, which has chlorophyllous guard cells. Leaves of both species had an apparent quantum yield for assimilation of about 0.05, with photosynthesis saturating at 0.300 to 0.400 millimoles per square meter per second. The response of assimilation to changes in CO/sub 2/ was similar in the two species, but the response of conductance was consistently weaker in Paphiopedilum than in Phragmipedium.more » The data suggest involvement of guard cell chloroplasts in the stomatal response to CO/sub 2/ and in the coupling of assimilation and conductance in the intact leaf.« less

  20. Heap/stack guard pages using a wakeup unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gooding, Thomas M; Satterfield, David L; Steinmacher-Burow, Burkhard

    A method and system for providing a memory access check on a processor including the steps of detecting accesses to a memory device including level-1 cache using a wakeup unit. The method includes invalidating level-1 cache ranges corresponding to a guard page, and configuring a plurality of wakeup address compare (WAC) registers to allow access to selected WAC registers. The method selects one of the plurality of WAC registers, and sets up a WAC register related to the guard page. The method configures the wakeup unit to interrupt on access of the selected WAC register. The method detects access ofmore » the memory device using the wakeup unit when a guard page is violated. The method generates an interrupt to the core using the wakeup unit, and determines the source of the interrupt. The method detects the activated WAC registers assigned to the violated guard page, and initiates a response.« less

Top