Sample records for guide tubes

  1. Development and Technology Transfer of the Syncro Blue Tube (Gabriel) Magnetically Guided Feeding Tube

    DTIC Science & Technology

    2017-06-01

    other documentation. TITLE: Development and Technology Transfer of the Syncro Blue Tube (Gabriel) Magnetically Guided Feeding Tube REPORT DOCUMENTATION...TITLE AND SUBTITLE Development and Technology Transfer of the Syncro Blue Tube (Gabriel) Magnetically Guided Feeding Tube 5a. CONTRACT NUMBER W81XWH-09-2...Technical Abstract: Further Development and Technology Transfer of the Syncro BLUETUBE™ (Gabriel) Magnetically Guided Feeding Tube. New Primary

  2. Turbine nozzle stage having thermocouple guide tube

    DOEpatents

    Schotsch, Margaret Jones; Kirkpatrick, Francis Lawrence; Lapine, Eric Michael

    2002-01-01

    A guide tube is fixed adjacent opposite ends in outer and inner covers of a nozzle stage segment. The guide tube is serpentine in shape between the outer and inner covers and extends through a nozzle vane. An insert is disposed in the nozzle vane and has apertures to accommodate serpentine portions of the guide tube. Cooling steam is also supplied through chambers of the insert on opposite sides of a central insert chamber containing the guide tube. The opposite ends of the guide tube are fixed to sleeves, in turn fixed to the outer and inner covers.

  3. Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures.

    PubMed

    Park, Jin Hoon; Kang, Dong-Ho; Lee, Moon Kyu; Yoo, Byoungwoo; Jung, Sang Ku; Hwang, Soo-Hyun; Kim, Jeoung Hee; Oh, Sunkyu; Lee, Eun Jung; Jeon, Sang Ryong; Roh, Sung Woo; Rhim, Seung Chul

    2016-05-01

    A retrospective cohort study. The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; P = 0.047). Straight-probe AOSF yielded larger direction angles without injuring bone and disc. Complications were absent. The procedure was easier than guide-tube AOSF and assured sufficient engagement, even in horizontal fracture orientation cases. 3.

  4. Neutron guide

    DOEpatents

    Greene, Geoffrey L.

    1999-01-01

    A neutron guide in which lengths of cylindrical glass tubing have rectangular glass plates properly dimensioned to allow insertion into the cylindrical glass tubing so that a sealed geometrically precise polygonal cross-section is formed in the cylindrical glass tubing. The neutron guide provides easier alignment between adjacent sections than do the neutron guides of the prior art.

  5. Study on convection improvement of standard vacuum tube

    NASA Astrophysics Data System (ADS)

    He, J. H.; Du, W. P.; Qi, R. R.; He, J. X.

    2017-11-01

    For the standard all-glass vacuum tube collector, enhancing the vacuum tube axial natural convection can improve its thermal efficiency. According to the study of the standard all-glass vacuum tube, three kinds of guide plates which can inhibit the radial convection and increase axial natural convection are designed, and theory model is established. Experiments were carried out on vacuum tubes with three types of baffles and standard vacuum tubes without the improvement. The results show that T-type guide plate is better than that of Y-type guide plate on restraining convection and increasing axial radial convection effect, Y type is better than that of flat plate type, all guide plates are better than no change; the thermal efficiency of the tube was 2.6% higher than that of the unmodified standard vacuum tube. The efficiency of the system in the experiment can be increased by 3.1%.

  6. DIY guide-needle-assisted conjunctivodacryocystorhinostomy (CDCR).

    PubMed

    Paik, Ji-Sun; Kim, Su-Ah; Doh, Sang-Hee

    2013-01-01

    In this study, we introduce DIY guide-needle-assisted conjunctivodacryocystorhinostomy (CDCR), in which a guide needle helps in measuring the initial Jones tube length for insertion and reduces unnecessary handling for tube changes. Three CDCR procedures were conducted in which the length of the Jones tube was calculated using a 22-gauge DIY guide needle, and a prospective study of tube position change and migration, (a major cause of CDCR failure) was done. Wound healing was almost complete within 4 weeks postoperatively in the osteotomy site, but in cases of partial middle turbinectomy, a little more time was necessary. There was a slight change in Jones tube position in the nasal cavity compared with the expected position of original tube tip, but no tube migration from the caruncle fixation position had occurred by the final follow-up time. This guide-needle-assisted CDCR has multiple advantages, such as easy measurement of the proper initial tube size, utilization of the initial needle path, and easy replacement of tubes. Finally, this approach to CDCR can be readily applied because it uses materials ordinarily found in hospitals to create the devices needed for the procedure, so there is no additional cost.

  7. Telescoping tube assembly

    NASA Technical Reports Server (NTRS)

    Sturm, Albert J. (Inventor); Marrinan, Thomas E. (Inventor)

    1995-01-01

    An extensible and retractable telescoping tube positions test devices that inspect large stationary objects. The tube has three dimensional adjustment capabilities and is vertically suspended from a frame. The tube sections are independently supported with each section comprising U-shaped housing secured to a thicker support plate. Guide mechanisms preferably mounted only to the thicker plates guide each tube section parallel to a reference axis with improved accuracy so that the position of the remote end of the telescoping tube is precisely known.

  8. Mechanical properties of a bioabsorbable nerve guide tube for long nerve defects.

    PubMed

    Ichihara, S; Facca, S; Liverneaux, P; Inada, Y; Takigawa, T; Kaneko, K; Nakamura, T

    2015-09-01

    The mechanical properties of nerve guide tubes must be taken into consideration when they are being developed. We previously reported the feasibility of using 50:50 tubes in a canine 40mm peroneal nerve defect model, where 50:50 represents the proportion of poly(L-lactic) acid (PLLA) and polyglycolic acid (PGA). The aim of the current study was to show that 50:50 tubes have suitable mechanical properties for repairing long nerve defects. Four types of nerve guide tubes made with PLLA to PGA fiber ratios of 100:0 (i.e. 100% PLLA) (100:0 tube), 50:50 (50:50 tube), 10:90 (10:90 tube), and 0:100 (0:100 tube) were designed and created using a tubular braiding machine. Their mechanical properties were examined in vitro (up to 16 weeks). In compression testing, 50:50 tubes had the highest normalized force value, followed in order by the 100:0, 10:90, and 0:100 tubes up to 8 weeks after immersion. From the point of view of biomechanics and bioresorbability, out of the 4 tube types tested, 50:50 tubes appeared to have the optimal mechanical properties for longer nerve defects. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  9. Preparation and characterization of electrical conductive PVA based materials for peripheral nerve tube-guides.

    PubMed

    Gonçalves, C; Ribeiro, J; Pereira, T; Luís, A L; Mauricio, A C; Santos, J D; Lopes, M A

    2016-08-01

    Peripheral nerve regeneration is a serious clinical problem. Presently, there are several nerve tube-guides available in the market, however with some limitations. The goal of this work was the development of a biomaterial with high electrical conductivity to produce tube-guides for nerve regeneration after neurotmesis injuries whenrver an end-to-end suture without tension is not possible. A matrix of poly(vinyl alcohol) (PVA) was used loaded with the following electrical conductive materials: COOH-functionalized multiwall carbon nanotubes (MWCNTs), poly(pyrrole) (PPy), magnesium chloride (MgCl2 ), and silver nitrate (AgNO3 ). The tube-guide production was carried out by a freezing/thawing process (physical crosslinking) with a final annealing treatment. After producing the tube-guide for nerve regeneration, the physicochemical characterization was performed. The most interesting results were achieved by loading PVA with 0.05% of PPy or COOH- functionalized CNTs. These tubes combined the electrical conductivity of carbon nanotubes (CNTs) and PPy with the biocompatibility of PVA matrix, with potential clinical application for nerve regeneration. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1981-1987, 2016. © 2016 Wiley Periodicals, Inc.

  10. Fluoroscopy-Guided Pull-Through Gastrostomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pitton, M. B., E-mail: pitton@radiologie.klinik.uni-mainz.de; Herber, S.; Dueber, C.

    2008-01-15

    The purpose of this study was to simplify a fluoroscopy guided gastrostomy technique using pull-type tubes which are traditionally introduced with gastroscopic assistance. The stomach was transorally probed with a 5-Fr catheter and a guidewire. A second access was performed percutaneously through the anterior abdominal and gastric wall using an 8-Fr sheath and an 8-Fr guiding catheter. A duplicated guidewire was introduced through the guiding catheter in order to result in a great custom-made loop within the stomach. The transoral guidewire was captured and tightened with this loop and the guiding catheter, and both were subsequently pulled by the transoralmore » guidewire until the tip of the guiding catheter exited the mouth. A thread was fed through the guiding catheter for fixation of the pull-type gastrostomy tube. Finally, the fixed tube was pulled through the esophagus into the stomach and through the abdominal wall until the anterior gastric wall fixed the retention plate of the tube. Thirty-seven patients (28 male, 9 female; age, 65.1 {+-} 14.4 years) with miscellaneous indications for percutaneous gastrostomies were supplied with pull-type gastrostomy catheters in a fluoroscopy technique without endoscopic assistance. Twenty-five of the 37 patients (67.6%) had undergone unsuccessful preceding gastroscopically guided PEG attempts because of tumor stenosis (n = 12) or impossible transillumination of the abdominal wall (n = 13). All procedures were technically successful, without major complications. Particularly, all patients with frustrating gastroscopic attempts were successfully provided with pull-type gastrostomy tubes. Five minor complications occurred: one tube loss during the passage of the hypopoharynx because of a torn thread, one transient small leakage alongside the tube (both successfully treated), and three cases of transient moderate local pain without leakage (symptomatic treatment). We conclude that this fluoroscopy-guided pull-through gastrostomy technique is easy and safe to perform and may be suggested as a standard procedure for radiological gastrostomies. It combines the ease of the radiological approach with the advantages of the pull-type tube devices, particularly the benefits of the typical retention plates.« less

  11. Cuff inflation-supplemented laryngoscope-guided nasal intubation: a comparison of three endotracheal tubes.

    PubMed

    Kumar, Rakesh; Gupta, Ekta; Kumar, Sunil; Rani Sharma, Kavita; Rani Gupta, Neera

    2013-03-01

    Softer endotracheal (ET) tubes are more difficult to navigate in the oropharynx than the stiffer polyvinyl chloride (PVC) tubes during nasotracheal intubation (NTI). Cuff inflation has been used to guide PVC tubes into the laryngeal inlet during blind NTI, but it has not been tested when performing NTI under direct laryngoscopic guidance. We assessed the role of cuff inflation in improving oropharyngeal navigation of 3 ET tubes of varying stiffness during direct laryngoscope-guided NTI. Simultaneously, we also assessed and compared the nasotracheal navigability and incidence of nasal injury with these ET tubes during cuff inflation-supplemented, laryngoscope-guided NTI. One hundred sixty-two adults were randomized to undergo NTI with either a conventional PVC (n = 54), wire reinforced (WR; n = 54) or a silicone-tipped WR (SWR; n = 54) ET tube. Ease of insertion of these tubes was assessed during passage from nose into oropharynx, from oropharynx into laryngeal inlet aided by cuff inflation if needed, and from laryngeal inlet into trachea. Nasal morbidity was assessed by a blinded observer. All ET tubes could be inserted into the trachea. Seventy-one of 162 ET tubes could be inserted from the oropharynx into the laryngeal inlet without cuff inflation. Eighty-six of the remaining 91 tubes that did not enter the laryngeal inlet without cuff inflation could be inserted when using the cuff inflation technique. Thus, a total of 157 ET tubes could be inserted into the laryngeal inlet with cuff inflation (95% confidence interval of difference of proportions between total number of tubes passed [157] and those without cuff inflation [71]: 53% [45%-61%]). The remaining 5 tubes had to be inserted with the help of Magill forceps. The incidence of epistaxis was lowest with the SWR tube (difference of proportions [95% confidence interval] SWR versus PVC 27% [8%-45%]; SWR versus WR 20% [1%-38%]; WR versus PVC 7% [-12% to 26%]). The cuff inflation technique consistently improved the oropharyngeal insertion of the 3 ET tubes of varying stiffness during direct laryngoscope-guided NTI. Supplemented with the cuff inflation technique, the SWR ET tube seems to be better than the PVC and WR ET tubes in terms of complete nasotracheal navigability and less perioperative nasal injury.

  12. Vibration dampener for dampening vibration of a tubular member

    DOEpatents

    Obermeyer, Franklin D.; Middlebrooks, Willis B.; DeMario, Edmund E.

    1994-01-01

    Vibration dampener for dampening vibration of a tubular member, such as an instrumentation tube of the type found in nuclear reactor pressure vessels. The instrumentation tube is received in an outer tubular member, such as a guide thimble tube. The vibration dampener comprises an annular sleeve which is attachable to the inside surface of the guide thimble tube and which is sized to surround the instrumentation tube. Dimples are attached to the interior wall of the sleeve for radially supporting the instrumentation tube. The wall of the sleeve has a flexible spring member, which is formed from the wall, disposed opposite the dimples for biasing the instrumentation tube into abutment with the dimples. Flow-induced vibration of the instrumentation tube will cause it to move out of contact with the dimples and further engage the spring member, which will flex a predetermined amount and exert a reactive force against the instrumentation tube to restrain its movement. The amount by which the spring member will flex is less than the unrestrained amplitude of vibration of the instrumentation tube. The reactive force exerted against the instrumentation tube will be sufficient to return it to its original axial position within the thimble tube. In this manner, vibration of the instrumentation tube is dampened so that in-core physics measurements are accurate and so that the instrumentation tube will not wear against the inside surface of the guide thimble tube.

  13. Excitation condition analysis of guided wave on PFA tubes for ultrasonic flow meter.

    PubMed

    Li, Xuan; Xiao, Xufeng; Cao, Li

    2016-12-01

    Impurity accumulation, which decreases the accuracy of flow measurement, is a critical problem when applying Z-shaped or U-shaped ultrasonic flow meters on straight PFA tubes. It can be expected that the guided wave can be used to implement flow measurement on straight PFA tubes. In this paper, the propagation of guided wave is explained by finite element simulations for the flow meter design. Conditions of guided wave generation, including the excitation frequency and the wedge structure, are studied in the simulations. The wedge is designed as a cone which is friendly to be manufactured and installed. The cone angle, the piezoelectric wafer's resonant frequency and the vibration directions are studied in the simulations. The simulations shows that the propagation of guided wave in thin PFA tubes is influenced by the piezoelectric wafers' resonant frequency and the vibration direction when the mode is on the 'water line'. Based on the results of the simulations, an experiment is conducted to verify the principles of excitation conditions, which performs flow measurement on a straight PFA tube well. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Manifold tool guide

    DOEpatents

    Djordjevic, A.

    1982-07-08

    A tool guide that makes possible the insertion of cleaning and/or inspection tools into a manifold pipe that will dislocate and extract the accumulated sediment in such manifold pipes. The tool guide basically comprises a right angled tube (or other angled tube as required) which can be inserted in a large tube and locked into a radially extending cross pipe by adjustable spacer rods and a spring-loaded cone, whereby appropriate cleaning tools can be inserted into to cross pipe for cleaning, inspection, etc.

  15. Manifold tool guide

    DOEpatents

    Djordjevic, A.

    1983-12-27

    A tool guide is described that makes possible the insertion of cleaning and/or inspection tools into a manifold pipe that will dislocate and extract the accumulated sediment in such manifold pipes. The tool guide basically comprises a right angled tube (or other angled tube as required) which can be inserted in a large tube and locked into a radially extending cross pipe by adjustable spacer rods and a spring-loaded cone, whereby appropriate cleaning tools can be inserted into the cross pipe for cleaning, inspection, etc. 3 figs.

  16. Manifold tool guide

    DOEpatents

    Djordjevic, Aleksandar

    1983-12-27

    A tool guide that makes possible the insertion of cleaning and/or inspection tools into a manifold pipe that will dislocate and extract the accumulated sediment in such manifold pipes. The tool guide basically comprises a right angled tube (or other angled tube as required) which can be inserted in a large tube and locked into a radially extending cross pipe by adjustable spacer rods and a spring-loaded cone, whereby appropriate cleaning tools can be inserted into to cross pipe for cleaning, inspection, etc.

  17. Sprouting angiogenesis in human midterm uterus and fallopian tube is guided by endothelial tip cells.

    PubMed

    Rusu, M C; Motoc, A G M; Pop, F; Folescu, R

    2013-01-01

    Five samples of human midterm fetal uterus and fallopian tube (four donor bodies) were used to assess whether or not processes of angiogenesis are guided by endothelial tip cells (ETCs), and if cytokine-receptors, such as CD117/c-kit and PDGFR-α, are expressed in the microenvironment of the endothelial tubes. CD34 labeled microvessels in the uterine wall (myometrium and endometrium) and in the wall of the uterine (fallopian) tube, and accurately identified ETCs in both organs. We conclude that sprouting angiogenesis in the developing human female tract is guided by ETCs. Moreover, CD117/c-kit antibodies labeled mural networks of pericytes, α-SMA-positive and desmin-negative, related to the endometrial (but not myometrial) microvessels, and similar labeling was identified in the wall of the uterine tube. PDGFR-α positive labeling, stromal and pericytary, was also found. Thus, sprouting angiogenesis in human fetal genital organs appears to be guided by tip cells and is influenced by tyrosine kinase receptor signaling.

  18. Vibration dampener for dampening vibration of a tubular member

    DOEpatents

    Obermeyer, F.D.; Middlebrooks, W.B.; DeMario, E.E.

    1994-10-18

    Vibration dampener for dampening vibration of a tubular member, such as an instrumentation tube of the type found in nuclear reactor pressure vessels is disclosed. The instrumentation tube is received in an outer tubular member, such as a guide thimble tube. The vibration dampener comprises an annular sleeve which is attachable to the inside surface of the guide thimble tube and which is sized to surround the instrumentation tube. Dimples are attached to the interior wall of the sleeve for radially supporting the instrumentation tube. The wall of the sleeve has a flexible spring member, which is formed from the wall, disposed opposite the dimples for biasing the instrumentation tube into abutment with the dimples. Flow-induced vibration of the instrumentation tube will cause it to move out of contact with the dimples and further engage the spring member, which will flex a predetermined amount and exert a reactive force against the instrumentation tube to restrain its movement. The amount by which the spring member will flex is less than the unrestrained amplitude of vibration of the instrumentation tube. The reactive force exerted against the instrumentation tube will be sufficient to return it to its original axial position within the thimble tube. In this manner, vibration of the instrumentation tube is dampened so that in-core physics measurements are accurate and so that the instrumentation tube will not wear against the inside surface of the guide thimble tube. 14 figs.

  19. Crimp sealing of tubes flush with or below a fixed surface

    DOEpatents

    Fischer, J.E.; Walmsley, D.; Wapman, P.D.

    1996-08-20

    An apparatus for crimp sealing and severing tubes flush or below a fixed surface. Tube crimping below a fixed surface requires an asymmetric die and anvil configuration. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes. This asymmetric die and anvil is used when a ductile metal tube and valve assembly are attached to a pressure vessel which has a fixed surface around the base of the tube at the pressure vessel. A flat anvil is placed against the tube. Die guides are placed against the tube on a side opposite the anvil. A pinch-off die is inserted into the die guides against the tube. Adequate clearance for inserting the die and anvil around the tube is needed below the fixed surface. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes. 8 figs.

  20. Crimp sealing of tubes flush with or below a fixed surface

    DOEpatents

    Fischer, Jon E.; Walmsley, Don; Wapman, P. Derek

    1996-01-01

    An apparatus for crimp sealing and severing tubes flush or below a fixed surface. Tube crimping below a fixed surface requires an asymmetric die and anvil configuration. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes. This asymmetric die and anvil is used when a ductile metal tube and valve assembly are attached to a pressure vessel which has a fixed surface around the base of the tube at the pressure vessel. A flat anvil is placed against the tube. Die guides are placed against the tube on a side opposite the anvil. A pinch-off die is inserted into the die guides against the tube. Adequate clearance for inserting the die and anvil around the tube is needed below the fixed surface. The anvil must be flat so that, after crimping, it may be removed without deforming the crimped tubes.

  1. Optical coupler

    DOEpatents

    Majewski, Stanislaw; Weisenberger, Andrew G.

    2004-06-15

    In a camera or similar radiation sensitive device comprising a pixilated scintillation layer, a light guide and an array of position sensitive photomultiplier tubes, wherein there exists so-called dead space between adjacent photomultiplier tubes the improvement comprising a two part light guide comprising a first planar light spreading layer or portion having a first surface that addresses the scintillation layer and optically coupled thereto at a second surface that addresses the photomultiplier tubes, a second layer or portion comprising an array of trapezoidal light collectors defining gaps that span said dead space and are individually optically coupled to individual position sensitive photomultiplier tubes. According to a preferred embodiment, coupling of the trapezoidal light collectors to the position sensitive photomultiplier tubes is accomplished using an optical grease having about the same refractive index as the material of construction of the two part light guide.

  2. Horizontal Advanced Tensiometer

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2004-06-22

    An horizontal advanced tensiometer is described that allows the monitoring of the water pressure of soil positions, particularly beneath objects or materials that inhibit the use of previous monitoring wells. The tensiometer includes a porous cup, a pressure transducer (with an attached gasket device), an adaptive chamber, at least one outer guide tube which allows access to the desired horizontal position, a transducer wire, a data logger and preferably an inner guide tube and a specialized joint which provides pressure on the inner guide tube to maintain the seal between the gasket of the transducer and the adaptive chamber.

  3. Method for automatically scramming a nuclear reactor

    DOEpatents

    Ougouag, Abderrafi M.; Schultz, Richard R.; Terry, William K.

    2005-12-27

    An automatically scramming nuclear reactor system. One embodiment comprises a core having a coolant inlet end and a coolant outlet end. A cooling system operatively associated with the core provides coolant to the coolant inlet end and removes heated coolant from the coolant outlet end, thus maintaining a pressure differential therebetween during a normal operating condition of the nuclear reactor system. A guide tube is positioned within the core with a first end of the guide tube in fluid communication with the coolant inlet end of the core, and a second end of the guide tube in fluid communication with the coolant outlet end of the core. A control element is positioned within the guide tube and is movable therein between upper and lower positions, and automatically falls under the action of gravity to the lower position when the pressure differential drops below a safe pressure differential.

  4. Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.

    PubMed

    Tsujimoto, Yukio; Nose, Yorihito; Ohba, Kenkichi

    2003-01-01

    The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.

  5. Detecting pin diversion from pressurized water reactors spent fuel assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ham, Young S.; Sitaraman, Shivakumar

    Detecting diversion of spent fuel from Pressurized Water Reactors (PWR) by determining possible diversion including the steps of providing a detector cluster containing gamma ray and neutron detectors, inserting the detector cluster containing the gamma ray and neutron detectors into the spent fuel assembly through the guide tube holes in the spent fuel assembly, measuring gamma ray and neutron radiation responses of the gamma ray and neutron detectors in the guide tube holes, processing the gamma ray and neutron radiation responses at the guide tube locations by normalizing them to the maximum value among each set of responses and takingmore » the ratio of the gamma ray and neutron responses at the guide tube locations and normalizing the ratios to the maximum value among them and producing three signatures, gamma, neutron, and gamma-neutron ratio, based on these normalized values, and producing an output that consists of these signatures that can indicate possible diversion of the pins from the spent fuel assembly.« less

  6. Safety and Efficacy of Electromagnetic-Guided Bedside Placement of Nasoenteral Feeding Tubes versus Standard Placement.

    PubMed

    Shadid, Husam; Keckeisen, Maureen; Zarrinpar, Ali

    2017-10-01

    Although enteral feeding in critically ill patients has been shown to be beneficial, reliable postpyloric placement of feeding tubes remains a challenge. The standard of care involves blind placement, frequently requiring multiple attempts, and radiographs. To evaluate the effect of electromagnetic-guided bedside placement in reducing time to establishment of feeding, lung placement, use of radiography, and cost, we initiated a prospective trial using electromagnetic-guided bedside placement and compared them to a retrospective cohort. Fifty-three consecutive placements of nasoenteral feeding tubes were made using electromagnetic-guidance on patients requiring enteral nutrition in a surgical intensive care unit at a tertiary care center. Sixty-three placement attempts in the preceding seven months served as controls. There were no significant differences between the two groups in terms of age, sex, weight, body mass index, hiatal or ventral hernias, or previous esophageal/gastric operations. The number of radiographs needed per patient, need for fluoroscopy, radiology charge per patient for the tube placement, and time from first attempt at placement to confirmation of postpyloric location were lower for the electromagnetic-guided group. Use of electromagnetic guidance allows reliable and cost-effective postpyloric enteral feeding tube placement compared with blind insertion.

  7. On guided circumferential waves in soft electroactive tubes under radially inhomogeneous biasing fields

    NASA Astrophysics Data System (ADS)

    Wu, Bin; Su, Yipin; Chen, Weiqiu; Zhang, Chuanzeng

    2017-02-01

    Soft electroactive (EA) tube actuators and many other cylindrical devices have been proposed recently in literature, which show great advantages over those made from conventional hard solid materials. However, their practical applications may be limited because these soft EA devices are prone to various failure modes. In this paper, we present an analysis of the guided circumferential elastic waves in soft EA tube actuators, which has potential applications in the in-situ nondestructive evaluation (NDE) or online structural health monitoring (SHM) to detect structural defects or fatigue cracks in soft EA tube actuators and in the self-sensing of soft EA tube actuators based on the concept of guided circumferential elastic waves. Both circumferential SH and Lamb-type waves in an incompressible soft EA cylindrical tube under inhomogeneous biasing fields are considered. The biasing fields, induced by the application of an electric voltage difference to the electrodes on the inner and outer cylindrical surfaces of the EA tube in addition to an axial pre-stretch, are inhomogeneous in the radial direction. Dorfmann and Ogden's theory of nonlinear electroelasticity and the associated linear theory for small incremental motion constitute the basis of our analysis. By means of the state-space formalism for the incremental wave motion along with the approximate laminate technique, dispersion relations are derived in a particularly efficient way. For a neo-Hookean ideal dielectric model, the proposed approach is first validated numerically. Numerical examples are then given to show that the guided circumferential wave propagation characteristics are significantly affected by the inhomogeneous biasing fields and the geometrical parameters. Some particular phenomena such as the frequency veering and the nonlinear dependence of the phase velocity on the radial electric voltage are discussed. Our numerical findings demonstrate that it is feasible to use guided circumferential elastic waves for the ultrasonic non-destructive online SHM to detect interior structural defects or fatigue cracks and for the self-sensing of the actual state of the soft EA tube actuator.

  8. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    PubMed

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube suction. The ESAT© is the first validated tool to systematically guide endotracheal nursing practice for the "inexperienced" nurse. © 2018 John Wiley & Sons Ltd.

  9. A simple customized surgical guide for orthodontic miniplates with tube.

    PubMed

    Paek, Janghyun; Su, Ming-Jeaun; Kwon, Soon-Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2012-09-01

    This article reports the use of a customized surgical guide for simple and precise C-tube plate placement with minimized incision. Patients who were planning to have orthodontic miniplate treatment because of narrow interradicular space were recruited for this study. A combined silicone and stainless steel wire surgical guide for the C-tube was fabricated on the cast model. The taller wire of the positioning guide is used to accurately start the incision. The incision guide-wire position is verified by placing the miniplate on the coronal horizontal wire to confirm that the incision will coordinate with the screw holes. Because the miniplate is firmly held in place, there is no risk of the miniplate anchoring screws (diameter, 1.5 mm; length, 4 mm) sliding on the bone surface during placement with a manual hand driver. The surgical guide was placed on the clinical site, and it allowed precise placement of the miniplate with minimum incision and preventing from slippage or path-of-insertion angulation errors that might interfere with accurate placement. Customized surgical guide enables precise planning for miniplate positions in anatomically complex sites.

  10. Vadose zone isobaric well

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2001-01-01

    A deep tensiometer is configured with an outer guide tube having a vented interval along a perforate section at its lower end, which is isolated from atmospheric pressure at or above grade. A transducer having a monitoring port and a reference port is located within a coaxial inner guide tube. The reference port of the transducer is open to the vented interval of the outer guide tube, which has the same gas pressure as in the sediment surrounding the tensiometer. The reference side of the pressure transducer is thus isolated from the effects of atmospheric pressure changes and relative to pressure changes in the material surrounding the tensiometer measurement location and so it is automatically compensated for such pressure changes.

  11. Integrated head package for top mounted nuclear instrumentation

    DOEpatents

    Malandra, Louis J.; Hornak, Leonard P.; Meuschke, Robert E.

    1993-01-01

    A nuclear reactor such as a pressurized water reactor has an integrated head package providing structural support and increasing shielding leading toward the vessel head. A reactor vessel head engages the reactor vessel, and a control rod guide mechanism over the vessel head raises and lowers control rods in certain of the thimble tubes, traversing penetrations in the reactor vessel head, and being coupled to the control rods. An instrumentation tube structure includes instrumentation tubes with sensors movable into certain thimble tubes disposed in the fuel assemblies. Couplings for the sensors also traverse penetrations in the reactor vessel head. A shroud is attached over the reactor vessel head and encloses the control rod guide mechanism and at least a portion of the instrumentation tubes when retracted. The shroud forms a structural element of sufficient strength to support the vessel head, the control rod guide mechanism and the instrumentation tube structure, and includes radiation shielding material for limiting passage of radiation from retracted instrumentation tubes. The shroud is thicker at the bottom adjacent the vessel head, where the more irradiated lower ends of retracted sensors reside. The vessel head, shroud and contents thus can be removed from the reactor as a unit and rested safely and securely on a support.

  12. Illuminating system and method for specialized and decorative lighting using liquid light guides

    DOEpatents

    Zorn, C.J.; Kross, B.J.; Majewski, S.; Wojcik, R.F.

    1998-08-25

    The present invention comprises an illumination system for specialized decorative lighting including a light source, a flexible plastic tube sheath for distributing the light to a remote location, a transparent liquid core filling the tube that has an index of refraction greater than that of the plastic tube and an arrangement where light coupled from the light source is caused to leak from the liquid light guide at desired locations for the purposes of specialized lighting, such as underwater illumination in swimming pools. 5 figs.

  13. Illuminating system and method for specialized and decorative lighting using liquid light guides

    DOEpatents

    Zorn, Carl J.; Kross, Brian J.; Majewski, Stanislaw; Wojcik, Randolph F.

    1998-01-01

    The present invention comprises an illumination system for specialized decorative lighting including a light source, a flexible plastic tube sheath for distributing the light to a remote location, a transparent liquid core filling the tube that has an index of refraction greater than that of the plastic tube and an arrangement where light coupled from the light source is caused to leak from the liquid light guide at desired locations for the purposes of specialized lighting, such as underwater illumination in swimming pools.

  14. Manual tube-to-tubesheet welding torch

    DOEpatents

    Kiefer, Joseph H.; Smith, Danny J.

    1982-01-01

    A welding torch made of a high temperature plastic which fits over a tube intermediate the ends thereof for welding the juncture between the tube and the back side of a tube plate and has a ballooned end in which an electrode, filler wire guide, fiber optic bundle, and blanketing gas duct are disposed.

  15. Pulmonary Intraparenchymal Blood Patching Decreases the Rate of Pneumothorax-Related Complications following Percutaneous CT-Guided Needle Biopsy.

    PubMed

    Graffy, Peter; Loomis, Scott B; Pickhardt, Perry J; Lubner, Meghan G; Kitchin, Douglas R; Lee, Fred T; Hinshaw, J Louis

    2017-04-01

    To investigate whether an autologous intraparenchymal blood patch (IPB) reduces the rate of pneumothorax-related complications associated with computed tomography (CT)-guided lung biopsies. This study included 834 patients: 482 who received an IPB and 352 who did not. Retrospective review was performed of all CT-guided lung biopsies performed at a single institution between August 2006 and September 2013. Patients were excluded if no aerated lung was crossed. The rate of pneumothorax, any associated intervention (eg, catheter placement, aspiration), chest tube placement, and chest tube replacement requiring hospital admission were compared by linear and multiple regression analysis. Patients who received an IPB had a significantly lower rate of pneumothorax (145 of 482 [30%] vs 154 of 352 [44%]; P < .0001), pneumothorax-related intervention (eg, catheter aspiration, pleural blood patch, chest tube placement; 43 of 482 [8.9%] vs 85 of 352 [24.1%]; P < .0001), and chest tube placement along with other determinants requiring hospital admission (18 of 482 [3.7%] vs 27 of 352 [7.7%]; P < .0001). No complications related to the IPB were noted in the study group. Autologous IPB placement is associated with a decreased rate of pneumothorax and associated interventions, including chest tube placement and hospital admission, after CT-guided lung biopsies, with no evidence of any adverse effects. These results suggest that an IPB is safe and effective and should be considered when aerated lung is traversed while performing a CT-guided lung biopsy. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  16. Mapping Self-Guided Learners' Searches for Video Tutorials on YouTube

    ERIC Educational Resources Information Center

    Garrett, Nathan

    2016-01-01

    While YouTube has a wealth of educational videos, how self-guided learners use these resources has not been fully described. An analysis of search engine queries for help with the use of Microsoft Excel shows that few users search for specific features or functions but instead use very general terms. Because the same videos are returned in…

  17. Design and performance of a punch mechanism based pellet injector for alternative injection in the large helical device

    NASA Astrophysics Data System (ADS)

    Mishra, J. S.; Sakamoto, R.; Motojima, G.; Matsuyama, A.; Yamada, H.

    2011-02-01

    A low speed single barrel pellet injector, using a mechanical punch device has been developed for alternative injection in the large helical device. A pellet is injected by the combined operation of a mechanical punch and a pneumatic propellant system. The pellet shape is cylindrical, 3 mm in diameter and 3 mm in length. Using this technique the speed of the pellet can be controlled flexibly in the range of 100-450 m/s, and a higher speed can be feasible for a higher gas pressure. The injector is equipped with a guide tube selector to direct the pellet to different injection locations. Pellets are exposed to several curved parts with the curvature radii Rc = 0.8 and 0.3 m when they are transferred in guided tubes to the respective injection locations. Pellet speed variation with pressure at different pellet formation temperatures has been observed. Pellet intactness tests through these guide tubes show a variation in the intact speed limit over a range of pellet formation temperatures from 6.5 to 9.8 K. Pellet speed reduction of less than 6% has been observed after the pellet moves through the curved guide tubes.

  18. Neutron source

    DOEpatents

    Cason, J.L. Jr.; Shaw, C.B.

    1975-10-21

    A neutron source which is particularly useful for neutron radiography consists of a vessel containing a moderating media of relatively low moderating ratio, a flux trap including a moderating media of relatively high moderating ratio at the center of the vessel, a shell of depleted uranium dioxide surrounding the moderating media of relatively high moderating ratio, a plurality of guide tubes each containing a movable source of neutrons surrounding the flux trap, a neutron shield surrounding one part of each guide tube, and at least one collimator extending from the flux trap to the exterior of the neutron source. The shell of depleted uranium dioxide has a window provided with depleted uranium dioxide shutters for each collimator. Reflectors are provided above and below the flux trap and on the guide tubes away from the flux trap.

  19. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    PubMed

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p < 0.0001. The stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  20. Simple and fast orotracheal intubation procedure in rats.

    PubMed

    Tomasello, Giovanni; Damiani, Francesco; Cassata, Giovanni; Palumbo, Vincenzo Davide; Sinagra, Emanuele; Damiani, Provvidenza; Bruno, Antonino; Cicero, Luca; Cupido, Francesco; Carini, Francesco; Lo Monte, Attilio Ignazio

    2016-05-06

    Endotracheal intubation in the rat is difficult because of the extremely small size of anatomical structures (oral cavity, epiglottis and vocal cords), small inlet for an endotracheal tube and the lack of proper technical instruments. In this study we used seventy rats weighting 400-500 g. The equipment needed for the intubation was an operating table, a longish of cotton, a cotton tip, orotracheal tube, neonatal laryngoscope blades, KTR4 small animal ventilator and isoflurane for inhalation anaesthesia. Premedication was carried out by medetomidine hydrochloride 1 mg/mL; then, thanks to a closed glass chamber, a mixture of oxygen and isoflurane was administered. By means of a neonatal laryngoscope the orotracheal tube was advanced into the oral cavity until the wire guide was visualized trough the vocal cords; then it was passed through them. The tube was introduced directly into the larynx over the wire guide; successively, the guide was removed and the tube placed into the trachea. Breathing was confirmed using a glove, cut at the end of a finger, simulating a small balloon. We achieved a fast and simple orotracheal intubation in all animals employed. We believe that our procedure is easier and faster than those previously reported in scientific literature.

  1. Gantry for medical particle therapy facility

    DOEpatents

    Trbojevic, Dejan

    2013-04-23

    A particle therapy gantry for delivering a particle beam to a patient includes a beam tube having a curvature defining a particle beam path and a plurality of superconducting, variable field magnets sequentially arranged along the beam tube for guiding the particle beam along the particle path. In a method for delivering a particle beam to a patient through a gantry, a particle beam is guided by a plurality of variable field magnets sequentially arranged along a beam tube of the gantry and the beam is alternately focused and defocused with alternately arranged focusing and defocusing variable field magnets.

  2. Gantry for medical particle therapy facility

    DOEpatents

    Trbojevic, Dejan [Wading River, NY

    2012-05-08

    A particle therapy gantry for delivering a particle beam to a patient includes a beam tube having a curvature defining a particle beam path and a plurality of fixed field magnets sequentially arranged along the beam tube for guiding the particle beam along the particle path. In a method for delivering a particle beam to a patient through a gantry, a particle beam is guided by a plurality of fixed field magnets sequentially arranged along a beam tube of the gantry and the beam is alternately focused and defocused with alternately arranged focusing and defocusing fixed field magnets.

  3. Use of PLGA 90:10 scaffolds enriched with in vitro-differentiated neural cells for repairing rat sciatic nerve defects.

    PubMed

    Luís, Ana L; Rodrigues, Jorge M; Geuna, Stefano; Amado, Sandra; Shirosaki, Yuki; Lee, Jennifer M; Fregnan, Federica; Lopes, Maria A; Veloso, Antonio P; Ferreira, Antonio J; Santos, Jose D; Armada-Da-silva, Paulo A S; Varejão, Artur S P; Maurício, Ana Colette

    2008-06-01

    Poly(lactic-co-glycolic acid) (PLGA) nerve tube guides, made of a novel proportion (90:10) of the two polymers, poly(L-lactide): poly(glycolide) and covered with a neural cell line differentiated in vitro, were tested in vivo for promoting nerve regeneration across a 10-mm gap of the rat sciatic nerve. Before in vivo testing, the PLGA 90:10 tubes were tested in vitro for water uptake and mass loss and compared with collagen sheets. The water uptake of the PLGA tubes was lower, and the mass loss was more rapid and higher than those of the collagen sheets when immersed in phosphate-buffered saline (PBS) solution. The pH values of immersing PBS did not change after soaking the collagen sheets and showed to be around 7.4. On the other hand, the pH values of PBS after soaking PLGA tubes decreased gradually during 10 days reaching values around 3.5. For the in vivo testing, 22 Sasco Sprague adult rats were divided into four groups--group 1: gap not reconstructed; group 2: gap reconstructed using an autologous nerve graft; group 3: gap reconstructed with PLGA 90:10 tube guides; group 4: gap reconstructed with PLGA 90:10 tube guides covered with neural cells differentiated in vitro. Motor and sensory functional recovery was evaluated throughout a healing period of 20 weeks using sciatic functional index, static sciatic index, extensor postural thrust, withdrawal reflex latency, and ankle kinematics. Stereological analysis was carried out on regenerated nerve fibers. Both motor and sensory functions improved significantly in the three experimental nerve repair groups, although the rate and extent of recovery was significantly higher in the group where the gap was reconstructed using the autologous graft. The presence of neural cells covering the inside of the PLGA tube guides did not make any difference in the functional recovery. By contrast, morphometric analysis showed that the introduction of N1E-115 cells inside PLGA 90:10 tube guides led to a significant lower number and size of regenerated nerve fibers, suggesting thus that this approach is not adequate for promoting peripheral nerve repair. Further studies are warranted to assess the role of other cellular systems as a foreseeable therapeutic strategy in peripheral nerve regeneration.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucholz, J.A.

    The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory is in the midst of a massive upgrade program to enhance experimental facilities. The reactor presently has four horizontal experimental beam tubes, all of which will be replaced or redesigned. The HB-2 beam tube will be enlarged to support more guide tubes, while the HB-4 beam tube will soon include a cold neutron source.

  5. MAP18 regulates the direction of pollen tube growth in Arabidopsis by modulating F-actin organization.

    PubMed

    Zhu, Lei; Zhang, Yan; Kang, Erfang; Xu, Qiangyi; Wang, Miaoying; Rui, Yue; Liu, Baoquan; Yuan, Ming; Fu, Ying

    2013-03-01

    For fertilization to occur in plants, the pollen tube must be guided to enter the ovule via the micropyle. Previous reports have implicated actin filaments, actin binding proteins, and the tip-focused calcium gradient as key contributors to polar growth of pollen tubes; however, the regulation of directional pollen tube growth is largely unknown. We reported previously that Arabidopsis thaliana MICROTUBULE-ASSOCIATED PROTEIN18 (MAP18) contributes to directional cell growth and cortical microtubule organization. The preferential expression of MAP18 in pollen and in pollen tubes suggests that MAP18 also may function in pollen tube growth. In this study, we demonstrate that MAP18 functions in pollen tubes by influencing actin organization, rather than microtubule assembly. In vitro biochemical results indicate that MAP18 exhibits Ca(2+)-dependent filamentous (F)-actin-severing activity. Abnormal expression of MAP18 in map18 and MAP18 OX plants was associated with disorganization of the actin cytoskeleton in the tube apex, resulting in aberrant pollen tube growth patterns and morphologies, inaccurate micropyle targeting, and fewer fertilization events. Experiments with MAP18 mutants created by site-directed mutagenesis suggest that F-actin-severing activity is essential to the effects of MAP18 on pollen tube growth direction. Our study demonstrates that in Arabidopsis, MAP18 guides the direction of pollen tube growth by modulating actin filaments.

  6. Nuclear fuel element nut retainer cup. [PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walton, L.A.

    1977-07-19

    A typical embodiment has an end fitting for a nuclear reactor fuel element that is joined to the control rod guide tubes by means of a nut plate assembly. The nut plate assembly has an array of nuts, each engaging the respective threaded end of the control rod guide tubes. The nuts, moreover, are retained on the plate during handling and before fuel element assembly by means of hollow cylindrical locking cups that are brazed to the plate and loosely circumscribe the individual enclosed nuts. After the nuts are threaded onto the respective guide tube ends, the locking cups aremore » partially deformed to prevent one or more of the nuts from working loose during reactor operation. The locking cups also prevent loose or broken end fitting parts from becoming entrained in the reactor coolant.« less

  7. Plasma arc welding weld imaging

    NASA Technical Reports Server (NTRS)

    Rybicki, Daniel J. (Inventor); Mcgee, William F. (Inventor)

    1994-01-01

    A welding torch for plasma arc welding apparatus has a transparent shield cup disposed about the constricting nozzle, the cup including a small outwardly extending polished lip. A guide tube extends externally of the torch and has a free end adjacent to the lip. First and second optical fiber bundle assemblies are supported within the guide tube. Light from a strobe light is transmitted along one of the assemblies to the free end and through the lip onto the weld site. A lens is positioned in the guide tube adjacent to the second assembly and focuses images of the weld site onto the end of the fiber bundle of the second assembly and these images are transmitted along the second assembly to a video camera so that the weld site may be viewed continuously for monitoring the welding process.

  8. 10 CFR 34.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... stop, “J” tube and collimator when it is used as an exposure head. Becquerel (Bq) means one... (Projection sheath) means a flexible or rigid tube (i.e., “J” tube) for guiding the source assembly and the... materials by nondestructive methods, utilizing ionizing radiation to make radiographic images. Lay-barge...

  9. 10 CFR 34.3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... stop, “J” tube and collimator when it is used as an exposure head. Becquerel (Bq) means one... (Projection sheath) means a flexible or rigid tube (i.e., “J” tube) for guiding the source assembly and the... materials by nondestructive methods, utilizing ionizing radiation to make radiographic images. Lay-barge...

  10. 10 CFR 34.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... stop, “J” tube and collimator when it is used as an exposure head. Becquerel (Bq) means one... (Projection sheath) means a flexible or rigid tube (i.e., “J” tube) for guiding the source assembly and the... materials by nondestructive methods, utilizing ionizing radiation to make radiographic images. Lay-barge...

  11. Monitoring of Soft Deposition Layers in Liquid-Filled Tubes with Guided Acoustic Waves Excited by Clamp-on Transducers.

    PubMed

    Tietze, Sabrina; Singer, Ferdinand; Lasota, Sandra; Ebert, Sandra; Landskron, Johannes; Schwuchow, Katrin; Drese, Klaus Stefan; Lindner, Gerhard

    2018-02-09

    The monitoring of liquid-filled tubes with respect to the formation of soft deposition layers such as biofilms on the inner walls calls for non-invasive and long-term stable sensors, which can be attached to existing pipe structures. For this task a method is developed, which uses an ultrasonic clamp-on device. This method is based on the impact of such deposition layers on the propagation of circumferential guided waves on the pipe wall. Such waves are partly converted into longitudinal compressional waves in the liquid, which are back-converted to guided waves in a circular cross section of the pipe. Validating this approach, laboratory experiments with gelatin deposition layers on steel tubes exhibited a distinguishable sensitivity of both wave branches with respect to the thickness of such layers. This allows the monitoring of the layer growth.

  12. Home Ventilator Guide

    MedlinePlus

    ... SpO 2 , low minute ventilation,apnea, high leak, non-vent- ed mask, circuit occlusion/discon- nect, malfunction, ... failure, block tube, tube discon- nect, high leak, non- vented mask, low minute volume, apnea, low SpO ...

  13. Atom Skimmers and Atom Lasers Utilizing Them

    NASA Technical Reports Server (NTRS)

    Hulet, Randall; Tollett, Jeff; Franke, Kurt; Moss, Steve; Sackett, Charles; Gerton, Jordan; Ghaffari, Bita; McAlexander, W.; Strecker, K.; Homan, D.

    2005-01-01

    Atom skimmers are devices that act as low-pass velocity filters for atoms in thermal atomic beams. An atom skimmer operating in conjunction with a suitable thermal atomic-beam source (e.g., an oven in which cesium is heated) can serve as a source of slow atoms for a magneto-optical trap or other apparatus in an atomic-physics experiment. Phenomena that are studied in such apparatuses include Bose-Einstein condensation of atomic gases, spectra of trapped atoms, and collisions of slowly moving atoms. An atom skimmer includes a curved, low-thermal-conduction tube that leads from the outlet of a thermal atomic-beam source to the inlet of a magneto-optical trap or other device in which the selected low-velocity atoms are to be used. Permanent rare-earth magnets are placed around the tube in a yoke of high-magnetic-permeability material to establish a quadrupole or octupole magnetic field leading from the source to the trap. The atoms are attracted to the locus of minimum magnetic-field intensity in the middle of the tube, and the gradient of the magnetic field provides centripetal force that guides the atoms around the curve along the axis of the tube. The threshold velocity for guiding is dictated by the gradient of the magnetic field and the radius of curvature of the tube. Atoms moving at lesser velocities are successfully guided; faster atoms strike the tube wall and are lost from the beam.

  14. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    PubMed Central

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (P<0.05), while the rate of complication was lower, in the ultrasound-guided thoracentesis cases compared to standard care treatment. In conclusion, ultrasound-guided thoracentesis catheter drainage is an efficient, safe and minimally invasive procedure to alleviate pleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  15. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and..., intervalometers, thermal batteries, hardened missile launching facilities, guided missile launchers and...

  16. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and..., intervalometers, thermal batteries, hardened missile launching facilities, guided missile launchers and...

  17. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and..., intervalometers, thermal batteries, hardened missile launching facilities, guided missile launchers and...

  18. Electromagnetically driven radiative shocks and their measurements

    NASA Astrophysics Data System (ADS)

    Kondo, K.; Nakajima, M.; Kawamura, T.; Horioka, K.

    2006-06-01

    Experimental results on a generation of strong shocks in a compact pulse power device are reported. To make a strong and plain shock wave, electrodes are tapered and an acrylic guiding tube is located on the top of the electrodes. It drives a quasi-one-dimensional strong shock in the guiding tube. When the front speed is more than the critical speed Drad, an interesting structure is confirmed at the shock front, which indicate a phenomenon proceeded by the radiative transport.

  19. Purposeful creation of a pneumothorax and chest tube placement to facilitate CT-guided coil localization of lung nodules before video-assisted thoracoscopic surgical wedge resection.

    PubMed

    Iqbal, Shams I; Molgaard, Christopher; Williamson, Christina; Flacke, Sebastian

    2014-07-01

    To evaluate the feasibility and efficacy of pneumothorax creation and chest tube insertion before computed tomography (CT)-guided coil localization of small peripheral lung nodules for video-assisted thoracoscopic surgical (VATS) wedge resection. From May 2011 to October 2013, 21 consecutive patients (seven men; mean age, 62 y; range, 42-76 y) scheduled for VATS wedge resection required CT-guided coil localization for small, likely nonpalpable peripheral lung lesions at a single institution. Outcomes were evaluated retrospectively for technical success and complications. There were 12 nodules and nine ground-glass opacities. Mean lesion distance from the pleural surface was 15 mm (range, 5-35 mm), and average size was 13 mm (range, 7-30 mm). A pneumothorax was successfully created in all patients with a Veress needle, and a chest tube was inserted. All target lesions were marked successfully, leaving one end of the coil within/beyond the lesion and the other end of the coil in the pleural space. The inserted chest tube was used to insufflate air to widen the pleural space during coil positioning and to aspirate any residual air before transfer of the patient to the operating room holding area. Intraparenchymal hemorrhages smaller than 7 cm in diameter developed in two patients during coil placement. All lesions were successfully resected with VATS. Histologic examinaiton revealed 13 primary adenocarcinomas, four metastases, and four benign lesions. Pneumothorax creation and chest tube placement before CT-guided coil localization of peripheral lung nodules for VATS wedge resection facilitates the deployment of the peripheral end of the coil in the pleural space and provides effective management of procedure-related pneumothorax until surgery. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  20. Traumatic Brain Injury: A Guide for Caregivers of Service Members and Veterans. Welcome

    DTIC Science & Technology

    2010-04-01

    Reed Army Medical Center, 33 percent had traumatic brain injury (as of March 2009). Due to medical and technological advances, we have seen a...Right to Appeal PEB Decision - Module 4, pages 139-141 PEG Tube (Per Cutaneous Gastronomy Tube) - Module 1, page 23 PRC (VA Polytrauma Rehabilitation...Per Cutaneous Gastronomy Tube (PEG tube) - Module 1, page 23 Peripheral Fatigue - Module 2, page 17 IN D EX 29 Permanent Disability Retired List (PDRL

  1. [Interventional Radiology for Intra-Abdominal Abscess after Gastrectomy].

    PubMed

    Matsuura, Norihiro; Fujitani, Kazumasa; Kawada, Junji; Nishikawa, Kazuhiro; Nakatsuka, Rie; Miyazaki, Susumu; Danno, Katsuki; Motoori, Masaaki; Kubota, Masaru; Matsuda, Chu; Yoshida, Hiroshi; Iwase, Kazuhiro; Tanaka, Yasuhiro

    2015-11-01

    Approximately 20% of patients develop some complications after gastrectomy. These complications should be treated appropriately to achieve a positive outcome. The records of 6 patients with postoperative intra-abdominal abscesses treated with interventional radiology (IVR) were analyzed. The cause of abscess was anastomotic leakage in 4 patients and contaminated surgery after gastric perforation in 2 patients. Intra-abdominal abscesses were detected on postoperative day 12 (median), and an IVR-guided drainage tube was inserted with a median interval of 1 day. The drainage tube was kept in place for 26 days (median), and patients were discharged 6.5 days (median) after drainage tube removal. No patients were converted to open surgery. Early IVR-guided drainage was essential and effective for intra-abdominal abscess treatment after gastrectomy.

  2. Fluoroscopically guided nose tube drainage of mediastinal abscesses in post-operative gastro-oesophageal anastomotic leakage.

    PubMed

    Xu, Q Y; Yin, G W; Chen, S X; Jiang, F; Bai, X J; Wu, J D

    2012-11-01

    The aim of this study was to retrospectively evaluate the technical success rates and clinical effectiveness of fluoroscopically guided nose tube drainage of mediastinal abscesses and a nasojejunum feeding tube in post-operative gastro-oesophageal anastomotic leakage (GEAL). From January 2006 to June 2011, 18 cases of post-operative GEAL with mediastinal abscesses after oesophagectomy with intrathoracic oesophagogastric anastomotic procedures for oesophageal and cardiac carcinoma were treated by insertion of a nose drainage tube and nasojejunum feeding tube under fluoroscopic guidance. We evaluated the feasibility of two-tube insertion to facilitate leakage site closure and complete resolution of the abscess, and the patients' nutritional benefit was also evaluated by checking the serum albumin level between pre- and post-enteral feeding via the feeding tube. The two tubes were placed successfully under fluoroscopic guidance in 18 patients (100%). The procedure time for two-tube insertion ranged from 20 to 40 min (mean 30 min). 17 patients (94%) achieved leakage site closure after two-tube insertion and had a good tolerance of two tubes in the nasal cavity. The serum albumin level was significant, increased from pre-enteral feeding (2.49 ± 0.42 g dl(-1)) to the post-enteral feeding (3.58 ± 0.47 g dl(-1)) via the feeding tube (p<0.001). The duration of follow-up ranged from 1 to 49 months (mean 19 months). The insertion of nose tube drainage and a nasojejunum feeding tube under fluoroscopic guidance is safe, and it provides effective relief from mediastinal abscesses in GEAL after oesophagectomy. Moreover, our findings indicate that two-tube insertion may be used as a selective procedure to treat mediastinal abscesses in post-operative GEAL. Advances in knowledge Directive drainage of mediastinal abscesses in post-operative GEAL may be an effective treatment.

  3. Laboratory Sampling Guide

    DTIC Science & Technology

    2012-05-11

    their uses: Table 10. Types of Solid Sorbent Tubes Tube Type Typical Uses Anasorb® 747 Methyl Ethyl Ketone , Ethylene Oxide Charcoal Tube...Silica Gel Aliphatic Amines, Methanol, Aldehydes , Acid Mist 2.5.3 Passive Samplers. Passive samplers do not require a sampling pump (Figure 9). They...often encountered within the first 6 inches of soil. Water-soluble contaminants such as metals, acids, ketones , and alcohols will be encountered at

  4. Examination system utilizing ionizing radiation and a flexible, miniature radiation detector probe

    DOEpatents

    Majewski, S.; Kross, B.J.; Zorn, C.J.; Majewski, L.A.

    1996-10-22

    An optimized examination system and method based on the Reverse Geometry X-Ray{trademark} (RGX{trademark}) radiography technique are presented. The examination system comprises a radiation source, at least one flexible, miniature radiation detector probe positioned in appropriate proximity to the object to be examined and to the radiation source with the object located between the source and the probe, a photodetector device attachable to an end of the miniature radiation probe, and a control unit integrated with a display device connected to the photodetector device. The miniature radiation detector probe comprises a scintillation element, a flexible light guide having a first end optically coupled to the scintillation element and having a second end attachable to the photodetector device, and an opaque, environmentally-resistant sheath surrounding the flexible light guide. The probe may be portable and insertable, or may be fixed in place within the object to be examined. An enclosed, flexible, liquid light guide is also presented, which comprises a thin-walled flexible tube, a liquid, preferably mineral oil, contained within the tube, a scintillation element located at a first end of the tube, closures located at both ends of the tube, and an opaque, environmentally-resistant sheath surrounding the flexible tube. The examination system and method have applications in non-destructive material testing for voids, cracks, and corrosion, and may be used in areas containing hazardous materials. In addition, the system and method have applications for medical and dental imaging. 5 figs.

  5. Examination system utilizing ionizing radiation and a flexible, miniature radiation detector probe

    DOEpatents

    Majewski, Stanislaw; Kross, Brian J.; Zorn, Carl J.; Majewski, Lukasz A.

    1996-01-01

    An optimized examination system and method based on the Reverse Geometry X-Ray.RTM. (RGX.RTM.) radiography technique are presented. The examination system comprises a radiation source, at least one flexible, miniature radiation detector probe positioned in appropriate proximity to the object to be examined and to the radiation source with the object located between the source and the probe, a photodetector device attachable to an end of the miniature radiation probe, and a control unit integrated with a display device connected to the photodetector device. The miniature radiation detector probe comprises a scintillation element, a flexible light guide having a first end optically coupled to the scintillation element and having a second end attachable to the photodetector device, and an opaque, environmentally-resistant sheath surrounding the flexible light guide. The probe may be portable and insertable, or may be fixed in place within the object to be examined. An enclosed, flexible, liquid light guide is also presented, which comprises a thin-walled flexible tube, a liquid, preferably mineral oil, contained within the tube, a scintillation element located at a first end of the tube, closures located at both ends of the tube, and an opaque, environmentally-resistant sheath surrounding the flexible tube. The examination system and method have applications in non-destructive material testing for voids, cracks, and corrosion, and may be used in areas containing hazardous materials. In addition, the system and method have applications for medical and dental imaging.

  6. Electromagnetic-guided placement of nasoduodenal feeding tubes versus endoscopic placement: a randomized, multicenter trial.

    PubMed

    Kappelle, Wouter F W; Walter, Daisy; Stadhouders, Paul H; Jebbink, Hendrik J A; Vleggaar, Frank P; van der Schaar, Peter J; Kappelle, Jan Willem; van der Tweel, Ingeborg; Van den Broek, Medard F M; Wessels, Frank J; Siersema, Peter D; Monkelbaan, Jan F

    2018-01-01

    Electromagnetic-guided placement (EMP) of a nasoduodenal feeding tube by trained nurses is an attractive alternative to EGD-guided placement (EGDP). We aimed to compare EMP and EGDP in outpatients, ward patients, and critically ill patients with normal upper GI anatomy. In 3 centers with no prior experience in EMP, patients were randomized to placement of a single-lumen nasoduodenal feeding tube either with EGDP or EMP. The primary endpoint was post-pyloric position of the tube on abdominal radiography. Patients were followed for 10 days to assess patency and adverse events. The analyses were performed according to the intention-to-treat principle. In total, 160 patients were randomized to EGDP (N = 76) or EMP (N = 84). Three patients withdrew informed consent, and no abdominal radiography was performed in 2 patients. Thus, 155 patients (59 intensive care unit, 38%) were included in the analyses. Rates of post-pyloric tube position between EGDP and EMP were comparable (79% vs 82%, odds ratio 1.16; 90% confidence interval, 0.58-2.38; P = .72). Adverse events were observed in 4 patients after EMP (hypoxia, GI blood loss, atrial fibrillation, abdominal pain) and in 4 after EGDP (epistaxis N = 2, GI blood loss, hypoxia). Costs of tube placements were lower for EMP compared with EGDP: $519.09 versus $622.49, respectively (P = .04). Success rates and safety of EMP and EGDP in patients with normal upper GI anatomy were comparable. Lower costs and potential logistic advantages may drive centers to adopt EMP as their new standard of care. (Clinical trial registration number: NTR4286.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. Complication Rates and Patency of Radiologically Guided Mushroom Gastrostomy, Balloon Gastrostomy, and Gastrojejunostomy: A Review of 250 Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yip, Doris; Vanasco, Matthew; Funaki, Brian

    2004-01-15

    To compare complication rates and tube performance of percutaneous mushroom gastrostomy, balloon gastrostomy, and gastrojejunostomy. Between September 9, 1999 and April 23, 2001, 203 patients underwent 250 radiologically guided percutaneous gastrostomy and gastrojejunostomy procedures. Follow-up was conducted through chart reviews and review of our interventional radiology database. Procedural and catheter-related complications were recorded. Chi-square statistical analysis was performed. In patients receiving mushroom-retained gastrostomy catheters (n = 114), the major complication rate was 0.88% (n = 1), the minor complication rate was 5.3% (n = 6), and the tube complication rate was 4.4% (n = 5). In patients receiving balloon-retained gastrostomymore » tubes (n = 67), the major complication rate was 0, the minor complication rate was 4.5% (n = 3), and the tube complication rate was 34.3% (n = 23). In patients receiving gastrojejunostomy catheters (n = 69), the major complication rate was 1.4% (n = 1), the minor complication rate was 2.9% (n = 2), and the tube complication rate was 34.8% (n = 24). No statistically significant differences were found between procedural or peri-procedural complications among the different types of tubes. Mushroom-retained catheters had significantly fewer tube complications (p < 0.01). Percutaneous gastrostomy and gastrojejunostomy have similar procedural and peri-procedural complication rates. Mushroom gastrostomy catheters have fewer tube-related complications compared with balloon gastrostomy and gastrojejunostomy catheters. In addition, mushroom-retained catheters exhibit the best overall long-term tube patency and are therefore the gastrostomy catheter of choice.« less

  8. Effects of mechanical loading on the degradability and mechanical properties of the nanocalcium-deficient hydroxyapatite–multi(amino acid) copolymer composite membrane tube for guided bone regeneration

    PubMed Central

    Duan, Hong; Yang, Hongsheng; Xiong, Yan; Zhang, Bin; Ren, Cheng; Min, Li; Zhang, Wenli; Yan, Yonggang; Li, Hong; Pei, Fuxing; Tu, Chongqi

    2013-01-01

    Background and methods Guided bone regeneration (GBR) is a new treatment for bone defects, and the property of membrane is critical to the success of GBR. This study focuses on a novel membrane tube for GBR, which was prepared by a nanocalcium-deficient hydroxyapatite–multi(amino acid) copolymer (n-CDHA-MAC) composite. The biomechanical strength and degradability of this membrane tube under mechanical loading after immersion in phosphate-buffered solution were investigated to evaluate the effects of mechanical loading on the membrane tube. The membrane-tube group with no mechanical loading and femora bone were used as controls. Results The compressive strength and bending strength of n-CDHA-MAC membrane tubes were 66.4 ± 10.2 MPa and 840.7 ± 12.1 MPa, which were lower than those of the goats’ femoral bones (69.0 ± 5.5 MPa and 900.2 ± 17.3 MPa), but there were no significant (P > 0.05) differences. In the in vitro degradability experiment, all membrane tubes were degradable and showed a surface-erosion degradation model. The PH of solution fluctuated from 7.2 to 7.5. The weight and mechanical strength of loaded tubes decreased more quickly than nonloaded ones, with significant differences (P < 0.05). However, the strength of the loaded group after degradation achieved 20.4 ± 1.2 MPa, which was greater than the maximum mechanical strength of 4.338 MPa based on goat femoral middle stationary state by three-dimensional finite-element analysis. Conclusions n-CDHA-MAC membrane tubes have good biomechanical strength during degradation under mechanical loading. Therefore, this membrane tube is an ideal GBR membrane for critical size defects of long bones in goats for animal experiments. PMID:23946651

  9. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

    PubMed

    Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi

    2010-12-01

    Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.

  10. The who, what, why, and how-to guide for gastrostomy tube placement in infants.

    PubMed

    Burd, Angela; Burd, Randall S

    2003-08-01

    The decision to place a gastrostomy tube in an infant can be confusing and difficult for both parents and professionals. A unified team approach is critical to communication and collaboration. Once the decision is made, coordinated parent education, discharge planning, and community integration are essential to facilitate a safe discharge. This article reviews the indications and options for gastrostomy placement, outlines current concepts in gastrostomy tube care, and answers the most frequently asked questions about the discharge and home care of infants with a gastrostomy tube.

  11. In situ repair of a failed compression fitting

    DOEpatents

    Wolbert, R.R.; Jandrasits, W.G.

    1985-08-05

    A method and apparatus for the in situ repair of a failed compression fitting is provided. Initially, a portion of a guide tube is inserted coaxially in the bore of the compression fitting and locked therein. A close fit dethreading device is then coaxially mounted on the guide tube to cut the threads from the fitting. Thereafter, the dethreading device and guide tube are removed and a new fitting is inserted onto the dethreaded fitting with the body of the new fitting overlaying the dethreaded portion. Finally, the main body of the new fitting is welded to the main body of the old fitting whereby a new threaded portion of the replacement fitting is precisely coaxial with the old threaded portion. If needed, a bushing is located on the dethreaded portion which is sized to fit snugly between the dethreaded portion and the new fitting. Preferably, the dethreading device includes a cutting tool which is moved incrementally in a radial direction whereby the threads are cut from the threaded portion of the failed fitting in increments.

  12. Twin-Screw Extruder and Pellet Accelerator Integration Developments for ITER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meitner, Steven J; Baylor, Larry R; Combs, Stephen Kirk

    The ITER pellet injection system consisting of a twinscrew frozen hydrogen isotope extruder, coupled to a combination solenoid actuated pellet cutter and pneumatic pellet accelerator, is under development at the Oak Ridge National Laboratory. A prototype extruder has been built to produce a continuous solid deuterium extrusion and will be integrated with a secondary section, where pellets are cut, chambered, and launched with a single-stage pneumatic accelerator into the plasma through a guide tube. This integrated pellet injection system is designed to provide 5 mm fueling pellets, injected at a rate up to 10 Hz, or 3 mm edge localizedmore » mode (ELM) triggering pellets, injected at higher rates up to 20 Hz. The pellet cutter, chamber mechanism, and the solenoid operated pneumatic valve for the accelerator are optimized to provide pellet velocities between 200-300 m/s to ensure high pellet survivability while traversing the inner wall fueling guide tubes, and outer wall ELMpacing guide tubes. This paper outlines the current twin-screwextruder design, pellet accelerator design, and the integrationrequired for both fueling and ELM pacing pellets.« less

  13. In situ repair of a failed compression fitting

    DOEpatents

    Wolbert, Ronald R.; Jandrasits, Walter G.

    1986-01-01

    A method and apparatus for the in situ repair of a failed compression fitg is provided. Initially, a portion of a guide tube is inserted coaxially in the bore of the compression fitting and locked therein. A close fit dethreading device is then coaxially mounted on the guide tube to cut the threads from the fitting. Thereafter, the dethreading device and guide tube are removed and a new fitting is inserted onto the dethreaded fitting with the body of the new fitting overlaying the dethreaded portion. Finally, the main body of the new fitting is welded to the main body of the old fitting whereby a new threaded portion of the replacement fitting is precisely coaxial with the old threaded portion. If needed, a bushing is located on the dethreaded portion which is sized to fit snugly between the dethreaded portion and the new fitting. Preferably, the dethreading device includes a cutting tool which is moved incrementally in a radial direction whereby the threads are cut from the threaded portion of the failed fitting in increments.

  14. Influence of upstream disturbance on the draft-tube flow of Francis turbine under part-load conditions

    NASA Astrophysics Data System (ADS)

    Chen, Ting; Zheng, Xianghao; Zhang, Yu-ning; Li, Shengcai

    2018-02-01

    Owing to the part-load operations for the enhancement of grid flexibility, the Francis turbine often suffers from severe low-frequency and large-amplitude hydraulic instability, which is mostly pertinent to the highly unsteady swirling vortex rope in the draft tube. The influence of disturbances in the upstream (e.g., large-scale vortex structures in the spiral casing) on the draft-tube vortex flow is not well understood yet. In the present paper, the influence of the upstream disturbances on the vortical flow in the draft tube is studied based on the vortex identification method and the analysis of several important parameters (e.g., the swirl number and the velocity profile). For a small guide vane opening (representing the part-load condition), the vortices triggered in the spiral casing propagate downstream and significantly affect the swirling vortex-rope precession in the draft tube, leading to the changes of the intensity and the processional frequency of the swirling vortex rope. When the guide vane opening approaches the optimum one (representing the full-load condition), the upstream disturbance becomes weaker and thus its influences on the downstream flow are very limited.

  15. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    PubMed

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (p<0.001), longer transparenchymal distance (p<0.001), and prone position (p=0.027). There was positive correlation between the need for chest tube placement and longer transparenchymal distance (p=0.007) and smaller lesion diameter (p=0.018). Lesions in the left lower lobe had the lowest rates of pneumothorax (p=0.008) and chest tube drainage (p=0.018). Patients whose pneumothoraces were diagnosed on the follow-up chest X-ray, but not on the immediate post-procedural CT scan had significantly higher requirement for chest tube drainage (p=0.039). CT-guided lung biopsy has a high rate of technical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Handling apparatus

    DOEpatents

    Cody, John P.; Kane, James J.

    1976-01-01

    1. A device of the character described comprising the combination of a guide tube having a normally open end, a support frame having a port therethrough, linkage means pivotally connected with the tube and with the frame and rotatably supporting the tube for movement between a position in longitudinal alignment with said port and with its open end in registry with the port and an additional position in which the tube lies adjacent the port with a side portion of the tube extending generally transversely across said port, an elongated track carried by said frame disposed generally parallel to and adjacent the tube in its said additional position, means connected with and projecting laterally from said tube adjacent its open end engaging and movable along said elongated track for cooperating with the track to direct the tube during movement between said positions, and means carried by the tube for moving an article therethrough toward and away from said port.

  17. 77 FR 63343 - Biweekly Notice: Applications and Amendments to Facility Operating Licenses and Combined Licenses...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-16

    ... PWR [Pressurized-Water Reactor] Steam Generator Tubes'' (Reference 32) and [Nuclear Energy Institute... maintains the required structural margins of the SG tubes for both normal and accident conditions. Nuclear Energy Institute 97-06, ``Steam Generator Program Guidelines'' (Reference 8), and NRC Regulatory Guide 1...

  18. Electronic skewing circuit monitors exact position of object underwater

    NASA Technical Reports Server (NTRS)

    Roller, R.; Yaroshuk, N.

    1967-01-01

    Linear Variable Differential Transformer /LVDT/ electronic skewing circuit guides a long cylindrical capsule underwater into a larger tube so that it does not contact the tube wall. This device detects movement of the capsule from a reference point and provides a continuous signal that is monitored on an oscilloscope.

  19. a Continuous Health Monitoring Guided Wave Fmd System for Retrofit to Existing Offshore Oilrigs

    NASA Astrophysics Data System (ADS)

    Mijarez, R.; Solis, L.; Martinez, F.

    2010-02-01

    An automatic health monitoring guided wave flood member detection (FMD) system, for retrofit to existing offshore oilrigs is presented. The system employs a microcontroller piezoelectric (PZT) based transmitter and a receiver instrumentation package composed of a PZT 40 kHz ultrasound transducer and a digital signal processor (DSP) module connected to a PC via USB for monitoring purposes. The transmitter and receiver were attached, non-intrusively, to the external wall of a steel tube; 1 m×27 cm×2 mm. Experiments performed in the laboratory have successfully identified automatically flooded tubes.

  20. Scaffolds from block polyurethanes based on poly(ɛ-caprolactone) (PCL) and poly(ethylene glycol) (PEG) for peripheral nerve regeneration.

    PubMed

    Niu, Yuqing; Chen, Kevin C; He, Tao; Yu, Wenying; Huang, Shuiwen; Xu, Kaitian

    2014-05-01

    Nerve guide scaffolds from block polyurethanes without any additional growth factors or protein were prepared using a particle leaching method. The scaffolds of block polyurethanes (abbreviated as PUCL-ran-EG) based on poly(ɛ-caprolactone) (PCL-diol) and poly(ethylene glycol) (PEG) possess highly surface-area porous for cell attachment, and can provide biochemical and topographic cues to enhance tissue regeneration. The nerve guide scaffolds have pore size 1-5 μm and porosity 88%. Mechanical tests showed that the polyurethane nerve guide scaffolds have maximum loads of 4.98 ± 0.35 N and maximum stresses of 6.372 ± 0.5 MPa. The histocompatibility efficacy of these nerve guide scaffolds was tested in a rat model for peripheral nerve injury treatment. Four types of guides including PUCL-ran-EG scaffolds, autograft, PCL scaffolds and silicone tubes were compared in the rat model. After 14 weeks, bridging of a 10 mm defect gap by the regenerated nerve was observed in all rats. The nerve regeneration was systematically characterized by sciatic function index (SFI), histological assessment including HE staining, immunohistochemistry, ammonia silver staining, Masson's trichrome staining and TEM observation. Results revealed that polyurethane nerve guide scaffolds exhibit much better regeneration behavior than PCL, silicone tube groups and comparable to autograft. Electrophysiological recovery was also seen in 36%, 76%, and 87% of rats in the PCL, PUCL-ran-EG, and autograft groups respectively, whilst 29.8% was observed in the silicone tube groups. Biodegradation in vitro and in vivo show proper degradation of the PUCL-ran-EG nerve guide scaffolds. This study has demonstrated that without further modification, plain PUCL-ran-EG nerve guide scaffolds can help peripheral nerve regeneration excellently. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Computed Tomographic Window Setting for Bronchial Measurement to Guide Double-Lumen Tube Size.

    PubMed

    Seo, Jeong-Hwa; Bae, Jinyoung; Paik, Hyesun; Koo, Chang-Hoon; Bahk, Jae-Hyon

    2018-04-01

    The bronchial diameter measured on computed tomography (CT) can be used to guide double-lumen tube (DLT) sizes objectively. The bronchus is known to be measured most accurately in the so-called bronchial CT window. The authors investigated whether using the bronchial window results in the selection of more appropriately sized DLTs than using the other windows. CT image analysis and prospective randomized study. Tertiary hospital. Adults receiving left-sided DLTs. The authors simulated selection of DLT sizes based on the left bronchial diameters measured in the lung (width 1,500 Hounsfield unit [HU] and level -700 HU), bronchial (1,000 HU and -450 HU), and mediastinal (400 HU and 25 HU) CT windows. Furthermore, patients were randomly assigned to undergo imaging with either the bronchial or mediastinal window to guide DLT sizes. Using the underwater seal technique, the authors assessed whether the DLT was appropriately sized, undersized, or oversized for the patient. On 130 CT images, the bronchial diameter (9.9 ± 1.2 mm v 10.5 ± 1.3 mm v 11.7 ± 1.3 mm) and the selected DLT size were different in the lung, bronchial, and mediastinal windows, respectively (p < 0.001). In 13 patients (17%), the bronchial diameter measured in the lung window suggested too small DLTs (28 Fr) for adults. In the prospective study, oversized tubes were chosen less frequently in the bronchial window than in the mediastinal window (6/110 v 23/111; risk ratio 0.38; 95% CI 0.19-0.79; p = 0.003). No tubes were undersized after measurements in these two windows. The bronchial measurement in the bronchial window guided more appropriately sized DLTs compared with the lung or mediastinal windows. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. PEG tubes: dealing with complications.

    PubMed

    Malhi, Hardip; Thompson, Rosie

    A percutaneous endoscopic gastronomy tube can be used to deliver nutrition, hydration and medicines directly into the patient's stomach. Patients will require a tube if they are unable to swallow safely, putting them at risk of aspiration of food, drink and medicines into their lungs. It is vital that nurses are aware of the complications that may arise when caring for a patient with a PEG tube. It is equally important that nurses know how to deal with these complications or from where tc seek advice. This article provides a quick troubleshooting guide to help nurses deal with complications that can arise with PEG feeding.

  3. Guided waves by axisymmetric and non-axisymmetric surface loading on hollow cylinders

    PubMed

    Shin; Rose

    1999-06-01

    Guided waves generated by axisymmetric and non-axisymmetric surface loading on a hollow cylinder are studied. For the theoretical analysis of the superposed guided waves, a normal mode concept is employed. The amplitude factors of individual guided wave modes are studied with respect to varying surface pressure loading profiles. Both theoretical and experimental focus is given to the guided waves generated by both axisymmetric and non-axisymmetric excitation. For the experiments, a comb transducer and high power tone burst function generator system are used on a sample Inconel tube. Surface loading conditions, such as circumferential loading angles and axial loading lengths, are used with the frequency and phase velocity to control the axisymmetric and non-axisymmetric mode excitations. The experimental study demonstrates the use of a practical non-axisymmetric partial loading technique in generating axisymmetric modes, particularly useful in the inspection of tubing and piping with limited circumferential access. From both theoretical and experimental studies, it also could be said that the amount of flexural modes reflected from a defect contains information on the reflector's circumferential angle, as well as potentially other classification and sizing feature information. The axisymmetric and non-axisymmetric guided wave modes should both be carefully considered for improvement of the overall analysis of guided waves generated in hollow cylinders.

  4. X-ray–free Ultrasound-guided Percutaneous Nephrolithotomy: How to Select the Right Patient?

    PubMed Central

    Usawachintachit, Manint; Tzou, David T.; Hu, Weiguo; Li, Jianxing; Chi, Thomas

    2017-01-01

    OBJECTIVE To identify factors associated with successful ultrasound guidance for each surgical step of ultrasound-guided percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS Consecutive patients undergoing PCNL between March 2015 and June 2016 were prospectively enrolled. An attempt was made to use ultrasound guidance in renal access, tract dilation, and nephrostomy tube placement for each patient. For steps during which ultrasound guidance was unsuccessful, fluoroscopic screening was applied. Regression analysis identified patient characteristics associated with successful use of ultrasound guidance. RESULTS A total of 96 patients composed this cohort, with a mean body mass index of 28.7 kg/m2. Mean stone size was 33.1 ± 18.9 mm, and no hydronephrosis was found in 63.5% of cases. Fluoroscopic screening was required for renal access in 27 cases (28.1%), tract dilation in 38 (39.6%), and nephrostomy tube placement in 80 (83.3%). Multivariate analysis demonstrated that successful ultrasound guidance was significantly associated with the presence of hydronephrosis for renal access and the absence of staghorn calculi for tract dilation. Ultrasound-guided nephrostomy tube placement appeared linked to surgeon experience. CONCLUSION To achieve completely x-ray–free ultrasound-guided PCNL, the ideal patient should have a hydronephrotic collecting system with no staghorn stone present. For practitioners looking to adopt ultrasound guidance into their PCNL practice, these represent the most appropriate patients to safely initiate a surgical experience. PMID:27720776

  5. Construction of nerve guide conduits from cellulose/soy protein composite membranes combined with Schwann cells and pyrroloquinoline quinone for the repair of peripheral nerve defect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Lihua; Center of Molecular Medicine, School of Medicine, Hubei University of Arts and Sciences, Xiangyang 441053; Gan, Li

    Regeneration and functional reconstruction of peripheral nerve defects remained a significant clinical challenge. Nerve guide conduits, with seed cells or neurotrophic factors (NTFs), had been widely used to improve the repair and regeneration of injured peripheral nerve. Pyrroloquinoline quinone (PQQ) was an antioxidant that can stimulate nerve growth factors (NGFs) synthesis and accelerate the Schwann cells (SCs) proliferation and growth. In present study, three kinds of nerve guide conduits were constructed: one from cellulose/SPI hollow tube (CSC), another from CSC combined with SCs (CSSC), and the third one from CSSC combined with PQQ (CSSPC), respectively. And then they were appliedmore » to bridge and repair the sciatic nerve defect in rats, using autograft as control. Effects of different nerve guide conduits on the nerve regeneration were comparatively evaluated by general analysis, sciatic function index (SFI) and histological analysis (HE and TEM). Newly-formed regenerative nerve fibers were observed and running through the transparent nerve guide conduits 12 weeks after surgery. SFI results indicated that the reconstruction of motor function in CSSPC group was better than that in CSSC and CSC groups. HE images from the cross-sections and longitudinal-sections of the harvested regenerative nerve indicated that regenerative nerve fibers had been formed and accompanied with new blood vessels and matrix materials in the conduits. TEM images also showed that lots of fresh myelinated and non-myelinated nerve fibers had been formed. Parts of vacuolar, swollen and abnormal axons occurred in CSC and CSSC groups, while the vacuolization and swell of axons was the least serious in CSSPC group. These results indicated that CSSPC group had the most ability to repair and reconstruct the nerve structure and functions due to the comprehensive contributions from hollow CSC tube, SCs and PQQ. As a result, the CSSPC may have the potential for the applications as nerve guide conduits in the field of nerve tissue engineering. - Highlights: • A novel nerve conduit was constructed and applied to repair nerve defect in rats. • Transparent hollow cellulose/soy protein isolate tube was used as conduit matrix. • Pyrroloquinoline quinine was adsorbed into the hollow tube as nerve growth factor. • Schwann cells were cultured into the hollow tube as seed cells. • The new nerve conduit could repair and reconstruct the peripheral nerve defects.« less

  6. Fundoplication and gastrostomy versus image-guided gastrojejunal tube for enteral feeding in neurologically impaired children with gastroesophageal reflux.

    PubMed

    Wales, Paul W; Diamond, Ivan R; Dutta, Sanjeev; Muraca, Sergio; Chait, Peter; Connolly, Bairbre; Langer, Jacob C

    2002-03-01

    Neurologically impaired children with gastroesophageal reflux (GER) usually are treated with a fundoplication and gastrostomy (FG); however, this approach is associated with a high rate of complications and morbidity. The authors evaluated the image-guided gastrojejunal tube (GJ) as an alternative approach for this group of patients. A retrospective review of 111 neurologically impaired patients with gastroesophageal reflux was performed. Patients underwent either FG (n = 63) or GJ (n = 48). All FGs were performed using an open technique by a pediatric surgeon, and all GJ tubes were placed by an interventional radiologist. The 2 groups were similar with respect to diagnosis, age, sex and indication for feeding tube. Patients in the GJ group were followed up for an average of 3.11 years, and those in the FG group for 5.71 years. The groups did not differ statistically with respect to most complications (bleeding, peritonitis, aspiration pneumonia, recurrent gastroesophageal reflux [GER], wound infection, failure to thrive, and death), subsequent GER related admissions, or cost. Children in the GJ group were more likely to continue taking antireflux medication after the procedure (P <.05). Also, there was a trend for GJ patients to have an increased incidence of bowel obstruction or intussusception (20.8% v 7.9%). Of the FG patients 36.5% experienced retching, and 12.7% experienced dysphagia. Eighty-five percent of patients in the GJ group experienced GJ tube-specific complications (breakage, blockage, dislodgment), and GJ tube manipulations were required an average of 1.68 times per year follow-up. Nine patients (14.3%) in the FG group had wrap failure, with 7 (11.1%) of these children requiring repeat fundoplication. In the GJ group, 8.3% of patients went on to require a fundoplication for persistent problems. A total of 14.5% of GJ patients had their tube removed by the end of the follow-up period because they no longer needed the tube for feeding. Image-guided gastrojejunal tubes are a reasonable alternative to fundoplication and gastrostomy for neurologically impaired children with GER. The majority can be inserted without general anesthesia. This technique failed in only 8.3% patients, and they subsequently required fundoplication. A total of 14.5% of GJ patients showed some spontaneous improvement and had their feeding tube removed. Each approach, however, still is associated with a significant complication rate. A randomized prospective study comparing these 2 approaches is needed. Copyright 2002 by W.B. Saunders Company.

  7. Float level switch for a nuclear power plant containment vessel

    DOEpatents

    Powell, J.G.

    1993-11-16

    This invention is a float level switch used to sense rise or drop in water level in a containment vessel of a nuclear power plant during a loss of coolant accident. The essential components of the device are a guide tube, a reed switch inside the guide tube, a float containing a magnetic portion that activates a reed switch, and metal-sheathed, ceramic-insulated conductors connecting the reed switch to a monitoring system outside the containment vessel. Special materials and special sealing techniques prevent failure of components and allow the float level switch to be connected to a monitoring system outside the containment vessel. 1 figures.

  8. Float level switch for a nuclear power plant containment vessel

    DOEpatents

    Powell, James G.

    1993-01-01

    This invention is a float level switch used to sense rise or drop in water level in a containment vessel of a nuclear power plant during a loss of coolant accident. The essential components of the device are a guide tube, a reed switch inside the guide tube, a float containing a magnetic portion that activates a reed switch, and metal-sheathed, ceramic-insulated conductors connecting the reed switch to a monitoring system outside the containment vessel. Special materials and special sealing techniques prevent failure of components and allow the float level switch to be connected to a monitoring system outside the containment vessel.

  9. Hydraulic balancing of a control component within a nuclear reactor

    DOEpatents

    Marinos, D.; Ripfel, H.C.F.

    1975-10-14

    A reactor control component includes an inner conduit, for instance containing neutron absorber elements, adapted for longitudinal movement within an outer guide duct. A transverse partition partially encloses one end of the conduit and meets a transverse wall within the guide duct when the conduit is fully inserted into the reactor core. A tube piece extends from the transverse partition and is coaxially aligned to be received within a tubular receptacle which extends from the transverse wall. The tube piece and receptacle cooperate in engagement to restrict the flow and pressure of coolant beneath the transverse partition and thereby minimize upward forces tending to expel the inner conduit.

  10. An Investigation of Accelerating Mechanisms in a Plasma Focus Relevant to Interrupting Switches.

    DTIC Science & Technology

    1983-07-01

    drift region so as to reduce beam loss due to contact with the conductive walls of the drift tube . The beam guiding apparatus was shown *i to increase...secondary discharge had an adverse effect on the trans- mission of the electron beam through the drift tube . This effect, which was shown to be...the electron beam from entering the drift tube region. .A -4 Io For CiA&- TAR - ’ ’--, U Unclassified SECURITY CLASSIFICATION OF THIS PAGEfhe, 00i Ent

  11. Semiconductor Nanomembrane Tubes: Three-Dimensional Confinement for Controlled Neurite Outgrowth

    PubMed Central

    Yu, Minrui; Huang, Yu; Ballweg, Jason; Shin, Hyuncheol; Huang, Minghuang; Savage, Donald E.; Lagally, Max G.; Dent, Erik W.; Blick, Robert H.; Williams, Justin C.

    2013-01-01

    In many neural culture studies, neurite migration on a flat, open surface does not reflect the three-dimensional (3D) microenvironment in vivo. With that in mind, we fabricated arrays of semiconductor tubes using strained silicon (Si) and germanium (Ge) nanomembranes and employed them as a cell culture substrate for primary cortical neurons. Our experiments show that the SiGe substrate and the tube fabrication process are biologically viable for neuron cells. We also observe that neurons are attracted by the tube topography, even in the absence of adhesion factors, and can be guided to pass through the tubes during outgrowth. Coupled with selective seeding of individual neurons close to the tube opening, growth within a tube can be limited to a single axon. Furthermore, the tube feature resembles the natural myelin, both physically and electrically, and it is possible to control the tube diameter to be close to that of an axon, providing a confined 3D contact with the axon membrane and potentially insulating it from the extracellular solution. PMID:21366271

  12. Magnetically-Guided Penetrant Applicator

    NASA Technical Reports Server (NTRS)

    Molina, Orlando G.

    1990-01-01

    Small wheeled vehicle moved inside nonmagnetic enclosure. Miniature magnetically guided truck uses foam-rubber sponge pads to apply penetrant fluid for inspection of welds in hidden surfaces of nonmagnetic tubes. Risk of explosion less than if electric motor used to drive vehicle. Inexpensive to make and made in range of sizes.

  13. Principal-Generated YouTube Video as a Method of Improving Parental Involvement

    ERIC Educational Resources Information Center

    Richards, Joey

    2013-01-01

    The purpose of this study was to evaluate the involvement level of parents and reveal whether principal-generated YouTube videos for regular communication would enhance levels of parental involvement at one North Texas Christian Middle School (pseudonym). The following questions guided this study: 1. What is the beginning level of parental…

  14. Traumatic Brain Injury: A Guide for Caregivers of Service Members and Veterans. Module 1: Introduction to Traumatic Brain Injury

    DTIC Science & Technology

    2010-04-01

    bruising. An MRI scan provides detailed images of the brain using magnetic energy rather than x-ray technology . Intracranial means within the...member/veteran is unable to swallow for many days to weeks, a per cutaneous gastronomy tube (PEG tube) will be placed directly into his or her

  15. Gated charged-particle trap

    DOEpatents

    Benner, W.H.

    1999-03-09

    The design and operation of a new type of charged-particle trap provides simultaneous measurements of mass, charge, and velocity of large electrospray ions. The trap consists of a detector tube mounted between two sets of center-bored trapping plates. Voltages applied to the trapping plates define symmetrically-opposing potential valleys which guide axially-injected ions to cycle back and forth through the charge-detection tube. A low noise charge-sensitive amplifier, connected to the tube, reproduces the image charge of individual ions as they pass through the detector tube. Ion mass is calculated from measurement of ion charge and velocity following each passage through the detector. 5 figs.

  16. Rockets: Physical Science Teacher's Guide with Activities.

    ERIC Educational Resources Information Center

    Vogt, Gregory L.; Rosenberg, Carla R., Ed.

    Rockets have evolved from simple tubes filled with black powder into mighty vehicles capable of launching a spacecraft out into the galaxy. The guide begins with background information sections on the history of rocketry, scientific principles, and practical rocketry. The sections on scientific principles and practical rocketry are based on Isaac…

  17. Fluoroscopically Guided Transcervical Fallopian Tube Recanalization of Post-Sterilization Reversal Mid-Tubal Obstructions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Houston, J. Graeme; Anderson, David; Mills, John

    2000-03-15

    Purpose: To assess the technical success and early outcome of fluoroscopically guided transcervical fallopian tube recanalization (FTR) in mid-tubal occlusion following sterilization reversal surgery.Methods: From July 1995 to January 1998, patients with greater than 12 months secondary infertility underwent hysterosalpingography (HSG). FTR was performed in proximal or mid-tubal occlusion. Cases of FTR in mid-tubal occlusion were included in this study. Technical success (defined as complete tubal patency) using a standard guidewire and hydrophilic glidewire, the number of patients with at least one patent tube, and the intrauterine and ectopic pregnancy rates were determined.Results: Twenty-six infertile patients with previous sterilization reversalmore » underwent HSG. Eight of 26 (31%) patients (mean age 32 years, range 23-37 years), had attempted FTR for mid-tubal occlusion at the site of surgical anastomosis. Fourteen tubes were attempted as there were two previous salpingectomies. Technical success was achieved in eight of 14 (57%) tubes attempted, resulting in five of eight (62%) patients having at least one patent tube. At follow-up (mean 18 months, range 12-28 months) in these five patients there was one intrauterine pregnancy. There were no ectopic pregnancies.Conclusions: FTR in mid-tubal obstruction in infertile patients following sterilization reversal surgery is technically feasible and may result in intrauterine pregnancy. In this small group there was a lower technical success rate and lower pregnancy rate than in unselected proximal tubal occlusion.« less

  18. Lifespan estimation of seal welded super stainless steels for water condenser of nuclear power plants

    NASA Astrophysics Data System (ADS)

    Kim, Young Sik; Park, Sujin; Chang, Hyun Young

    2014-01-01

    When sea water was used as cooling water for water condenser of nuclear power plants, commercial stainless steels can not be applied because chloride concentration exceeds 20,000 ppm. There are many opinions for the materials selection of tube and tube sheets of a condenser. This work reviewed the application guide line of stainless steels for sea-water facilities and the estimation equations of lifespan were proposed from the analyses of both field data for sea water condenser and experimental results of corrosion. Empirical equations for lifespan estimation were derived from the pit initiation time and re-tubing time of stainless steel tubing in sea water condenser of nuclear power plants. The lifespan of seal-welded super austenitic stainless steel tube/tube sheet was calculated from these equations. Critical pitting temperature of seal-welded PRE 50 grade super stainless steel was evaluated as 60 °C. Using the proposed equation in engineering aspect, tube pitting corrosion time of seal-welded tube/tube sheet was calculated as 69.8 years and re-tubing time was estimated as 82.0 years.

  19. Guide for preparing annual reports on radiation-safety testing of electronic products (general)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    For manufacturers of electronic products other than those for which a specific guide has been issued, the guide replaces the Guide for the Filing of Annual Reports (21 CFR Subchapter J, Section 1002.11), HHS Publication FDA 82-8127. The electronic product (general) annual reporting guide is applicable to the following products: products intended to produce x radiation (accelerators, analytical devices, therapy x-ray machines); microwave diathermy machines; cold-cathode discharge tubes; and vacuum switches and tubes operating at or above 15,000 volts. To carry out its responsibilities under Public Law 90-602, the Food and Drug Administration's Center for Devices and Radiological Health (CDRH)more » has issued a series of regulations contained in Title 21 of the Code of Federal Regulations (CFR). Part 1002 of 21 CFR deals with records and reports. Section 1002.61 categorizes electronic products into Groups A through C. Section 1002.30 requires manufacturers of products in Groups B and C to establish and maintain certain records, while Section 1002.11 requires such manufacturers to submit an Annual Report summarizing the contents of the required records. Section 1002.7 requires that reports conform to reporting guides issued by CDRH unless an acceptable justification for an alternate format is provided.« less

  20. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    PubMed

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  1. 78 FR 56655 - Foreign-Trade Zone (FTZ) 203-Moses Lake, Washington; Notification of Proposed Production Activity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-13

    ... choose the duty rate during customs entry procedures that applies to fuel rod assemblies (duty rate--3.3... plates; channels; spacers; end caps; springs; top and bottom nozzles; cages; guide tubes; and tubes, bar stocks, wires and plates of zirconium (duty rate ranges from 3.3 to 3.7%). Public comment is invited from...

  2. Sigmoid irrigation tube for the management of chronic evacuation disorders.

    PubMed

    Gauderer, Michael W L; Decou, James M; Boyle, John T

    2002-03-01

    Antegrade colonic irrigation, in which the right colon is accessed via appendicostomy or cecostomy, now is an important adjunct in the management of children with chronic evacuation disorders. However, in most children, the major area of dysfunction is the left rather than the right colon. The authors developed a simple, percutaneous endoscopic, laparoscopically controlled sigmoid irrigation tube placement and evaluated the results in 4 children. A rigid sigmoidoscope is advanced into the upper sigmoid and the loop brought in contact with the abdominal wall under laparoscopic control. A small skin incision is made and a needle pushed across the abdominal and sigmoid walls into the lumen of the sigmoidoscope. A guide wire is advanced through the needle into the scope and retrieved. After the scope is removed, a PEG-type catheter is attached to the guide wire and pulled back, securing the sigmoid loop to the abdominal wall. The tube is subsequently converted to a skin-level device by simply adding an external port valve. All 4 patients achieved prompt evacuation in the sitting position. Sigmoid tube for antegrade irrigation is an appealing alternative to conventional cecal access. The procedure is simple and may offer physiologic advantages. Copyright 2002 by W.B. Saunders Company.

  3. Hydrodynamic ultrasonic probe

    DOEpatents

    Day, Robert A.; Conti, Armond E.

    1980-01-01

    An improved probe for in-service ultrasonic inspection of long lengths of a workpiece, such as small diameter tubing from the interior. The improved probe utilizes a conventional transducer or transducers configured to inspect the tubing for flaws and/or wall thickness variations. The probe utilizes a hydraulic technique, in place of the conventional mechanical guides or bushings, which allows the probe to move rectilinearly or rotationally while preventing cocking thereof in the tube and provides damping vibration of the probe. The probe thus has lower friction and higher inspection speed than presently known probes.

  4. Preventing microbial biofilms on catheter tubes using ultrasonic guided waves.

    PubMed

    Wang, Huanlei; Teng, Fengmeng; Yang, Xin; Guo, Xiasheng; Tu, Juan; Zhang, Chunbing; Zhang, Dong

    2017-04-04

    Biofilms on indwelling tubes and medical prosthetic devices are among the leading causes of antibiotic-resistant bacterial infections. In this work, a new anti-biofilm catheter prototype was proposed. By combining an endotracheal tube (ET) with a group of ultrasonic guided wave (UGW) transducers, the general idea was to prevent bacteria aggregation with UGW vibrations. Based on quantitative analysis of UGW propagation, detailed approach was achieved through (a) selection of ultrasonic frequency, wave modes and vibration amplitude; and (b) adoption of wave coupling and 45° wave incidence technique. Performance of the proposed UGW-ET prototype was demonstrated via in vitro experiments, during which it deterred deposition of Pseudomonas aeruginosa (P. aeruginosa) biofilms successfully. With current configuration, UGW amplitudes ranged from 0.05-5 nm could be optimal to achieve biofilm prevention. This work sheds a light in the underlying mechanism of ultrasound-mediated biofilm prevention, and will inspire the development of new catheters of better antibacterial capability.

  5. Effect of microstructure of superalloy guide plate on its surface wear resistance

    NASA Astrophysics Data System (ADS)

    Zhou, Jianbo; Zhang, Xizhen

    2018-03-01

    The microstructure had been observed for guide plate, the guide plate be made of casting for groove controlling of hot rolled seamless tube, be produced for the production of 1600 seamless steel pipe,which cause obvious surface deformation and can not be normally produced. The alloy elements in matrix and precipitate phase of the guide plate were analyzed with the help of EDS. The results show that the wear resistance of the guide plate is directly affected by the fact that the guide plate is unable to form typical carbides, it shows that the formation of typical carbide strengthening plays an important role in improving the surface wear resistance of the guide plate.

  6. Content Analysis of Select YouTube Postings: Comparisons of Reactions to the Sandy Hook and Aurora Shootings and Hurricane Sandy.

    PubMed

    Miller, Eric D

    2015-11-01

    This study details an innovative and methodical content analysis of 2,207 YouTube comments from four different YouTube videos (e.g., breaking news or memorials) related to the 2012 Sandy Hook Elementary School and Aurora theater mass shootings and the catastrophic Hurricane Sandy. As expected, YouTube comments associated with the Sandy Hook shootings (particularly those from a memorial video) were especially likely to feature compassion and grief with lessened hostility. This study highlights differing online contexts by which individuals show grief and related emotions following man-made and natural calamities and how-even in an online environment-powerful situational contexts greatly guide behavior.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutcliffe, James, E-mail: jasutcliffe@gmail.com; Wigham, Andrew, E-mail: a.wigham@doctors.org.uk; Mceniff, Niall, E-mail: nmceniff@stjames.ie

    PurposeSurgical Gastrostomy has been around since the 19th century but in 1980 the first successful percutaneous endoscopic gastrostomy was reported. A year later the first successful percutaneous gastrostomy was performed using fluoroscopic guidance. The technique for percutaneous insertion and the equipment used has been refined since then and it is now considered the gold standard for gastrostomy insertion. Here we present guidelines for image-guided enteral feeding tubes in adults.Material and MethodWe performed a review and analysis of the scientific literature, other national and international guidelines and expert opinion.ResultsStudies have shown fluoroscopic techniques have consistently higher success rates with lower ratesmore » of major complications than endoscopic techniques. However, the Achilles' heel of many fluoroscopic techniques is the requirement for smaller gastrostomy tube sizes resulting in them being more prone to blockages and thus requiring further intervention.ConclusionRadiological feeding tube insertion is a safe and effective procedure. Success rates are higher, and complication rates lower than PEG or surgical gastrostomy tube placement and innovative techniques for gastric and jejunal access mean that there are very few cases in which RIG is not possible. The principal weakness of radiologically inserted gastrostomies is the limitiation on tube size which leads to a higher rate of tube blockage. Per-oral image-guided gastrostomies have to an extent addressed this but have not been popularised. Currently many centres still consider endoscopic gastrostomies as the first line unless patients are too unwell to undergo this procedure or previous attempts have failed, in which case radioloically inserted gastrostomies are the technique of choice.« less

  8. A new disruption mitigation valve (DMV) and gas flow in guiding tubes of different diameter

    NASA Astrophysics Data System (ADS)

    Finken, K. H.; Lehnen, M.; Bozhenkov, S. A.

    2011-03-01

    A new disruption mitigation valve, the DMV-30, has been developed and tested. The orifice output area of the valve is a factor of 2.4 and 12.25 times larger than that of its predecessors, DMV-20 and DMV-10, and the gas reservoir amounts to 1.3 L while the older version used at JET had only 0.65 L. The coil which provides the magnetic field pulse for the activation of the piston by an eddy current is outside of the working gas volume such that all gas volumes are now made of stainless steel. The valve has the advantages of the previous developments: it is robust and reproducible, opens fully within 3 ms and releases 50% of the gas within about 5 ms (He) to 10 ms (Ar). The valve is attached subsequently to two different guiding tubes, one with an inner diameter of 38 mm as used presently at JET and one with 102 mm inner diameter; the aim of this paper is the analysis of the gas flows for different diameters. The front of the gas pulse propagates with a Mach number of about 2.5 through the tubes, independent of the two diameters. This high speed agrees with theoretical expectations of flow expansion of a half infinite tube in vacuum. In the quasi-stationary phase of the expansion, the gas flows with about sound speed in the 102 mm tube and with about half of the sound speed in the 38 mm tube.

  9. Monte Carlo characterization of PWR spent fuel assemblies to determine the detectability of pin diversion

    NASA Astrophysics Data System (ADS)

    Burdo, James S.

    This research is based on the concept that the diversion of nuclear fuel pins from Light Water Reactor (LWR) spent fuel assemblies is feasible by a careful comparison of spontaneous fission neutron and gamma levels in the guide tube locations of the fuel assemblies. The goal is to be able to determine whether some of the assembly fuel pins are either missing or have been replaced with dummy or fresh fuel pins. It is known that for typical commercial power spent fuel assemblies, the dominant spontaneous neutron emissions come from Cm-242 and Cm-244. Because of the shorter half-life of Cm-242 (0.45 yr) relative to that of Cm-244 (18.1 yr), Cm-244 is practically the only neutron source contributing to the neutron source term after the spent fuel assemblies are more than two years old. Initially, this research focused upon developing MCNP5 models of PWR fuel assemblies, modeling their depletion using the MONTEBURNS code, and by carrying out a preliminary depletion of a ¼ model 17x17 assembly from the TAKAHAMA-3 PWR. Later, the depletion and more accurate isotopic distribution in the pins at discharge was modeled using the TRITON depletion module of the SCALE computer code. Benchmarking comparisons were performed with the MONTEBURNS and TRITON results. Subsequently, the neutron flux in each of the guide tubes of the TAKAHAMA-3 PWR assembly at two years after discharge as calculated by the MCNP5 computer code was determined for various scenarios. Cases were considered for all spent fuel pins present and for replacement of a single pin at a position near the center of the assembly (10,9) and at the corner (17,1). Some scenarios were duplicated with a gamma flux calculation for high energies associated with Cm-244. For each case, the difference between the flux (neutron or gamma) for all spent fuel pins and with a pin removed or replaced is calculated for each guide tube. Different detection criteria were established. The first was whether the relative error of the difference was less than 1.00, allowing for the existence of the difference within the margin of error. The second was whether the difference between the two values was big enough to prevent their error bars from overlapping. Error analysis was performed both using a one second count and pseudo-Maxwell statistics for a projected 60 second count, giving four criteria for detection. The number of guide tubes meeting these criteria was compared and graphed for each case. Further analysis at extremes of high and low enrichment and long and short burnup times was done using data from assemblies at the Beaver Valley 1 and 2 PWR. In all neutron flux cases, at least two guide tube locations meet all the criteria for detection of pin diversion. At least one location in almost all of the gamma flux cases does. These results show that placing detectors in the empty guide tubes of spent fuel bundles to identify possible pin diversion is feasible.

  10. A novel cluster-tube self-adaptive robot hand.

    PubMed

    Fu, Hong; Yang, Haokun; Song, Weishu; Zhang, Wenzeng

    2017-01-01

    This paper proposes a novel cluster-tube self-adaptive robot hand (CTSA Hand). The CTSA Hand consists of a base, a motor, a transmission mechanism, multiple elastic tendons, and a group of sliding-tube assemblies. Each sliding-tube assembly is composed of a sliding tube, a guide rod, two springs and a hinge. When the hand grasping an object, the object pushes some sliding tubes to different positions according to the surface shape of the object, the motor pulls the tendons tight to cluster tubes. The CTSA Hand can realize self-adaptive grasping of objects of different sizes and shapes. The CTSA Hand can grasp multiple objects simultaneously because the grasping of the hand acts as many grippers in different directions and heights. The grasping forces of the hand are adjusted by a closed-loop control system with potentiometer. Experimental results show that the CTSA Hand has the features of highly self-adaption and large grasping forces when grasping various objects.

  11. Gel spinning of silk tubes for tissue engineering

    PubMed Central

    Lovett, Michael; Cannizzaro, Christopher; Vunjak-Novakovic, Gordana; Kaplan, David L.

    2011-01-01

    Tubular vessels for tissue engineering are typically fabricated using a molding, dipping, or electrospinning technique. While these techniques provide some control over inner and outer diameters of the tube, they lack the ability to align the polymers or fibers of interest throughout the tube. This is an important aspect of biomaterial composite structure and function for mechanical and biological impact of tissue outcomes. We present a novel aqueous process system to spin tubes from biopolymers and proteins such as silk fibroin. Using silk as an example, this method of winding an aqueous solution around a reciprocating rotating mandrel offers substantial improvement in the control of the tube properties, specifically with regard to winding pattern, tube porosity, and composite features. Silk tube properties are further controlled via different post-spinning processing mechanisms such as methanol-treatment, air-drying, and lyophilization. This approach to tubular scaffold manufacture offers numerous tissue engineering applications such as complex composite biomaterial matrices, blood vessel grafts and nerve guides, among others. PMID:18801570

  12. Repair boundary for parent tube indications within the upper joint zone of hybrid expansion joint (HEJ) sleeved tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cullen, W.K.; Keating, R.F.

    1997-02-01

    In the Spring and Fall of 1994, and the Spring of 1995, crack-like indications were found in the upper hybrid expansion joint (HEJ) region of Steam Generator (S/G) tubes which had been sleeved using Westinghouse HEJ sleeves. As a result of these findings, analytic and test evaluations were performed to assess the effect of the degradation on the structural, and leakage, integrity of the sleeve/tube joint relative to the requirements of the United States Nuclear Regulatory Commission`s (NRC) draft Regulatory Guide (RG) 1.121. The results of these evaluations demonstrated that tubes with implied or known crack-like circumferential parent tube indicationsmore » (PTIs) located 1.1 inches or farther below the bottom of the hardroll upper transition, have sufficient, and significant, integrity relative to the requirements of RG 1.121. Thus, the purpose of this report is to provide background information related to the justification of the modified tube repair boundary.« less

  13. Common Femoral Artery Access on YouTube: What Practices are Being Shown and Who is Delivering the Message?

    PubMed

    Pitcher, Grayson S; Newton, Daniel H; Amendola, Michael F

    Novice learners are increasingly turning to YouTube as a learning resource for surgical procedures. One example of such a procedure is common femoral artery puncture and sheath placement. Practitioners in several specialties perform this procedure to access the arterial system for angiography and intervention. We set forth to compare the techniques demonstrated on YouTube by the various specialists, as well as compare each specialty׳s prevalence on this website. YouTube (www.youtube.com) was accessed in December 2015 at multiple time points with a cleared-cache web browser for the keyword search categories: "femoral artery access," "femoral access," and "angiography access." The top 500 videos from each of these keyword searches were analyzed. Videos were categorized by practitioner specialty, technique, duration of video, age of video, and total views. Videos with clear demonstration of femoral artery access were included in the analysis. All industry videos were excluded from the analysis. Categorical variables were compared using Fisher׳s exact test, and continuous variables were compared with the Student׳s t-test. A total of 2460, 4680 and 1800 videos were found for each keyword search, respectively. Of these, 33 videos clearly demonstrated femoral artery access technique. Vascular specialists, compared to interventional cardiology and radiology, had fewer videos (n = 4 vs. 14) and older videos (3.5 ± 2.1y vs. 2.25 ± 0.5y, p < 0.05). The vascular specialists demonstrated ultrasound-guided access, while interventional cardiology predominantly demonstrated landmark-guided access (p < 0.05). Although YouTube and other online resources are being used by novice learners, vascular specialists are underrepresented for femoral artery access, a foundational vascular procedure. Other practitioners demonstrate videos with landmark-guided access and rarely demonstrate ultrasound use. As recognized vascular experts, vascular surgeons should improve their visibility in online learning resources. Copyright © 2017 Association of Program Directors in Surgery. All rights reserved.

  14. A novel procedure employing laser ultrasound technique and simplex algorism for the characterization of mechanical and geometrical properties in Zircaloy tubes with different levels of hydrogen charging

    NASA Astrophysics Data System (ADS)

    Liu, I.-Hung; Yang, Che-Hua

    2011-01-01

    In this research, a procedure employing a laser ultrasound technique (LUT) and an inversion algorism is reported for nondestructive characterization of mechanical and geometrical properties in Zircaloy tubes with different levels of hydrogen charging. With the LUT, guided acoustic waves are generated to propagate in the Zircaloy tubes and are detected remotely by optical means. By measuring the dispersive wavespeeds followed by the inversion algorism, mechanical properties such as elastic moduli and geometrical property such as wall-thickness of Zircaloy tubes are characterized for different levels of hydrogen charging. Having the advantages of remote, non-contact and point-wise generation/detection, the reported procedure serves as a competitive candidate for the characterization of Zircaloy tubes generally operated in irradiative and temperature-elevated environments.

  15. Tube curvature measuring probe and method

    DOEpatents

    Sokol, George J.

    1990-01-01

    The present invention is directed to a probe and method for measuring the radius of curvature of a bend in a section of tubing. The probe includes a member with a pair of guide means, one located at each end of the member. A strain gauge is operatively connected to the member for detecting bending stress exrted on the member as the probe is drawn through and in engagement with the inner surface of a section of tubing having a bend. The method of the present invention includes steps utilizing a probe, like the aforementioned probe, which can be made to detect bends only in a single plane when having a fixed orientation relative the section of tubing to determine the maximum radius of curvature of the bend.

  16. Types of neural guides and using nanotechnology for peripheral nerve reconstruction

    PubMed Central

    Biazar, Esmaeil; Khorasani, MT; Montazeri, Naser; Pourshamsian, Khalil; Daliri, Morteza; T, Mostafa Rezaei; B, Mahmoud Jabarvand; Khoshzaban, Ahad; K, Saeed Heidari; Jafarpour, Mostafa; Roviemiab, Ziba

    2010-01-01

    Peripheral nerve injuries can lead to lifetime loss of function and permanent disfigurement. Different methods, such as conventional allograft procedures and use of biologic tubes present problems when used for damaged peripheral nerve reconstruction. Designed scaffolds comprised of natural and synthetic materials are now widely used in the reconstruction of damaged tissues. Utilization of absorbable and nonabsorbable synthetic and natural polymers with unique characteristics can be an appropriate solution to repair damaged nerve tissues. Polymeric nanofibrous scaffolds with properties similar to neural structures can be more effective in the reconstruction process. Better cell adhesion and migration, more guiding of axons, and structural features, such as porosity, provide a clearer role for nanofibers in the restoration of neural tissues. In this paper, basic concepts of peripheral nerve injury, types of artificial and natural guides, and methods to improve the performance of tubes, such as orientation, nanotechnology applications for nerve reconstruction, fibers and nanofibers, electrospinning methods, and their application in peripheral nerve reconstruction are reviewed. PMID:21042546

  17. Coded excitation speeds up the detection of the fundamental flexural guided wave in coated tubes

    NASA Astrophysics Data System (ADS)

    Song, Xiaojun; Moilanen, Petro; Zhao, Zuomin; Ta, Dean; Pirhonen, Jalmari; Salmi, Ari; Hæeggström, Edward; Myllylä, Risto; Timonen, Jussi; Wang, Weiqi

    2016-09-01

    The fundamental flexural guided wave (FFGW) permits ultrasonic assessment of the wall thickness of solid waveguides, such as tubes or, e.g., long cortical bones. Recently, an optical non-contact method was proposed for ultrasound excitation and detection with the aim of facilitating the FFGW reception by suppressing the interfering modes from the soft coating. This technique suffers from low SNR and requires iterative physical scanning across the source-receiver distance for 2D-FFT analysis. This means that SNR improvement achieved by temporal averaging becomes time-consuming (several minutes) which reduces the applicability of the technique, especially in time-critical applications such as clinical quantitative ultrasound. To achieve sufficient SNR faster, an ultrasonic excitation by a base-sequence-modulated Golay code (BSGC, 64-bit code pair) on coated tube samples (1-5 mm wall thickness and 5 mm soft coating layer) was used. This approach improved SNR by 21 dB and speeded up the measurement by a factor of 100 compared to using a classical pulse excitation with temporal averaging. The measurement now took seconds instead of minutes, while the ability to determine the wall thickness of the phantoms was maintained. The technique thus allows rapid noncontacting assessment of the wall thickness in coated solid tubes, such as the human bone.

  18. Improved drainage with active chest tube clearance.

    PubMed

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Reinforcement for percutaneous nephrostomy tubes with a new technique.

    PubMed

    Zhou, Tie; Gao, Xiaofeng; Yang, Cheng; Peng, Yonghan; Xiao, Liang; Xu, Chuanliang; Wang, Linhui; Hou, Jianguo; Sun, Yinghao

    2011-01-01

    Percutaneous nephrostomy (PCN) still plays a significant role in decompressing the renal collecting system. Percutaneous nephrostomy tubes (PNTs), however, which are flexible and may not be protected well by patients, are vulnerable to mechanical drag, although they are carefully fixed to the skin with silk suture. We developed a simple method to reinforce the nephrostomy tube against dislodgement from the skin. A total of 133 adult patients underwent ultrasonography-guided PCN; 85 patients received a conventional method to fix the tubes, while the other 48 patients received a new one. We used a rubber drainage tube, about 2 cm long, sheared longitudinally, as the outer tube to encase the nephrostomy tube, and then sutured the cutting edges together with the skin suture to reinforce the nephrostomy tube. Compared with the 85 patients who received the conventional method, there was not any tube dislodgement after PCN in the 48 patients who received the new one at the end of 2 weeks (0 vs 7, P=0.049) and 4 weeks (0 vs 10, P=0.014) follow-up. This is a simple, effective, and inexpensive method that can significantly decrease the dislodgement incidence of PNTs and keep them fixed well after surgery.

  20. A high-performance wave guide cryogenic thermal break

    NASA Astrophysics Data System (ADS)

    Melhuish, S. J.; McCulloch, M. A.; Piccirillo, L.; Stott, C.

    2016-10-01

    We describe a high-performance wave guide cryogenic thermal break. This has been constructed both for Ka band, using WR28 wave guide, and Q band, using WR22 wave guide. The mechanical structure consists of a hexapod (Stewart platform) made from pultruded carbon fibre tubing. We present a tentative examination of the cryogenic Young's modulus of this material. The thermal conductivity is measured at temperatures above the range explored by Runyan and Jones, resulting in predicted conductive loads through our thermal breaks of 3.7 mW to 3 K and 17 μK to 1 K.

  1. Flow separation in a straight draft tube, particle image velocimetry

    NASA Astrophysics Data System (ADS)

    Duquesne, P.; Maciel, Y.; Ciocan, G. D.; Deschênes, C.

    2014-03-01

    As part of the BulbT project, led by the Consortium on Hydraulic Machines and the LAMH (Hydraulic Machine Laboratory of Laval University), the efficiency and power break off in a bulb turbine has been investigated. Previous investigations correlated the break off to draft tube losses. Tuft visualizations confirmed the emergence of a flow separation zone at the wall of the diffuser. Opening the guide vanes tends to extend the recirculation zone. The flow separations were investigated with two-dimensional and two-component particle image velocimetry (PIV) measurements designed based on the information collected from tuft visualizations. Investigations were done for a high opening blade angle with a N11 of 170 rpm, at best efficiency point and at two points with a higher Q11. The second operating point is inside the efficiency curve break off and the last operating point corresponds to a lower efficiency and a larger recirculation region in the draft tube. The PIV measurements were made near the wall with two cameras in order to capture two measurement planes simultaneously. The instantaneous velocity fields were acquired at eight different planes. Two planes located near the bottom wall were parallel to the generatrix of the conical part of the diffuser, while two other bottom planes diverged more from the draft tube axis than the cone generatrix. The last four planes were located on the draft tube side and diverged more from the draft tube axis than the cone generatrix. By combining the results from the various planes, the separation zone is characterized using pseudo-streamlines of the mean velocity fields, maps of the Reynolds stresses and maps of the reverse-flow parameter. The analysis provides an estimation of the separation zone size, shape and unsteady character, and their evolution with the guide vanes opening.

  2. CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial.

    PubMed

    Kirchner, Johannes; Kickuth, Ralph; Laufer, Ulf; Schilling, Esther Maria; Adams, Stephan; Liermann, Dieter

    2002-03-01

    We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CTF guidance realizes a time-saving but increases the radiation exposure dosage.

  3. Numerical Investigation of the Flow Structure in a Kaplan Draft Tube at Part Load

    NASA Astrophysics Data System (ADS)

    Maddahian, R.; Cervantes, M. J.; Sotoudeh, N.

    2016-11-01

    This research presents numerical simulation of the unsteady flow field inside the draft tube of a Kaplan turbine at part load condition. Due to curvature of streamlines, the ordinary two-equations turbulence models fail to predict the flow features. Therefore, a modification of the Shear Stress Transport (SST-SAS) model is utilized to approximate the turbulent stresses. A guide vane, complete runner and draft tube are considered to insure the real boundary conditions at the draft tube inlet. The outlet boundary is assumed to discharge into the atmosphere. The obtained pressure fluctuations inside the draft tube are in good agreement with available experimental data. In order to further investigate the RVR formation and its movement, the λ2 criterion, relating the position of the vortex core and strength to the second largest Eigen value of the velocity gradient tensor, is employed. The method used for vortex identification shows the flow structure and vortex motion inside the draft tube accurately.

  4. Wall-ablative laser-driven in-tube accelerator

    NASA Astrophysics Data System (ADS)

    Sasoh, Akihiro; Suzuki, Shingo; Matsuda, Atsushi

    2008-05-01

    The laser-driven in-tube accelerator in which the propellant is supplied from laser-ablated gas from the tube wall was developed. Proof-of concept demonstrations of vertical launch were successfully done. The device had a 25mm X 25mm square cross-section; two opposing walls were made of polyacetal and acted as the propellant, the other two acrylic window with guide grooves to the projectile. The upper end of the launch tube was connected to a vacuum chamber of an inner volume of 0.8 m2, in which the initial pressure was set to lower than 20 Pa. With plugging the bottom end of the launch tube, a momentum coupling coefficient exceeding 2.5 mN/W was obtained. Even with the bottom end connected to the same vacuum chamber through a different duct, the projectile was vertical launched successfully, obtaining 0.14 mN/W.

  5. Illumination of interior spaces by bended hollow light guides: Application of the theoretical light propagation method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Darula, Stanislav; Kocifaj, Miroslav; Kittler, Richard

    2010-12-15

    To ensure comfort and healthy conditions in interior spaces the thermal, acoustics and daylight factors of the environment have to be considered in the building design. Due to effective energy performance in buildings the new technology and applications also in daylight engineering are sought such as tubular light guides. These allow the transport of natural light into the building core reducing energy consumption. A lot of installations with various geometrical and optical properties can be applied in real buildings. The simplest set of tubular light guide consists of a transparent cupola, direct tube with high reflected inner surface and amore » ceiling cover or diffuser redistributing light into the interior. Such vertical tubular guide is often used on flat roofs. When the roof construction is inclined a bend in the light guide system has to be installed. In this case the cupola is set on the sloped roof which collects sunlight and skylight from the seen part of the sky hemisphere as well as that reflected from the ground and opposite facades. In comparison with the vertical tube some additional light losses and distortions of the propagated light have to be expected in bended tubular light guides. Recently the theoretical model of light propagation was already published and its applications are presented in this study solving illuminance distributions on the ceiling cover interface and further illuminance distribution on the working plane in the interior. (author)« less

  6. Penetration of the Stigma and Style Elicits a Novel Transcriptome in Pollen Tubes, Pointing to Genes Critical for Growth in a Pistil

    PubMed Central

    Qin, Yuan; Leydon, Alexander R.; Manziello, Ann; Pandey, Ritu; Mount, David; Denic, Stojan; Vasic, Bane; Johnson, Mark A.; Palanivelu, Ravishankar

    2009-01-01

    Pollen tubes extend through pistil tissues and are guided to ovules where they release sperm for fertilization. Although pollen tubes can germinate and elongate in a synthetic medium, their trajectory is random and their growth rates are slower compared to growth in pistil tissues. Furthermore, interaction with the pistil renders pollen tubes competent to respond to guidance cues secreted by specialized cells within the ovule. The molecular basis for this potentiation of the pollen tube by the pistil remains uncharacterized. Using microarray analysis in Arabidopsis, we show that pollen tubes that have grown through stigma and style tissues of a pistil have a distinct gene expression profile and express a substantially larger fraction of the Arabidopsis genome than pollen grains or pollen tubes grown in vitro. Genes involved in signal transduction, transcription, and pollen tube growth are overrepresented in the subset of the Arabidopsis genome that is enriched in pistil-interacted pollen tubes, suggesting the possibility of a regulatory network that orchestrates gene expression as pollen tubes migrate through the pistil. Reverse genetic analysis of genes induced during pollen tube growth identified seven that had not previously been implicated in pollen tube growth. Two genes are required for pollen tube navigation through the pistil, and five genes are required for optimal pollen tube elongation in vitro. Our studies form the foundation for functional genomic analysis of the interactions between the pollen tube and the pistil, which is an excellent system for elucidation of novel modes of cell–cell interaction. PMID:19714218

  7. Enteral nutrition tube placement assisted by ultrasonography in patients with severe acute pancreatitis

    PubMed Central

    Li, Gang; Pan, Yiyuan; Zhou, Jing; Tong, Zhihui; Ke, Lu; Li, Weiqin

    2017-01-01

    Abstract To evaluate the effect of a novel procedure using real-time ultrasonography to assist nasojejunal tube placement at bedside in patients with severe acute pancreatitis (SAP). Single center, prospective descriptive study in a 15-bed surgery intensive care unit of a university hospital. Thirty SAP patients were enrolled. The whole procedure of placing nasojejunal tube was performed by a single physician, who places nasojejunal tube at the bedside and performs ultrasonography to guide the tube positioning. The final nasojejunal tube position was confirmed by abdominal radiograph. The successful rate of the procedure as well as the time it took, the time from the decision of enteral feeding to commencement of feeding, and complications were recorded. Thirty-six intubations were performed in 30 patients by using ultrasonography-assisted method at bedside. Nasojejunal tubes were successful placed in 28 of 30 patients (93.3%). The average time of successful placement was 22.07 ± 5.78 minutes. The median time between physician's decision for tube placement and feeding initiation was 5.5 (2, 24) hours. No adverse events occurred in all of patients. This novel method of nasojejunal tube placement under ultrasound guidance is practical, less time consuming and reliable. PMID:29137035

  8. Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrocelli, Francesco, E-mail: francesco.petrocelli@hsanmartino.it; Salsano, Giancarlo, E-mail: giancarlo.salsano@yahoo.it; Bovio, Giulio, E-mail: giulio.bovio@hsanmartino.it

    IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriformmore » sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.« less

  9. Ultrasound-Guided Vascular Access Simulator for Medical Training: Proposal of a Simple, Economic and Effective Model.

    PubMed

    Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio

    2017-03-01

    To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heberlein, Wolf E., E-mail: weheberlein@uams.edu; Goodwin, Whitney J.; Wood, Clint E.

    Purpose: Our study evaluated techniques for percutaneous gastrostomy (G)-tube placement without the use of a nasogastric (NG) tube. Instead, direct puncture of a physiologic air bubble or effervescent-enhanced gastric bubble distention was performed in patients with upper digestive tract obstruction (UDTO) or psychological objections to NG tubes. Materials and Methods: A total of 886 patients underwent G-tube placement in our department during a period of 7 years. We present our series of 85 (9.6%) consecutive patients who underwent percutaneous G-tube placement without use of an NG tube. Results: Of these 85 patients, fluoroscopic guided access was attempted by direct puncturemore » of a physiologically present gastric air bubble in 24 (28%) cases. Puncture of an effervescent-induced large gastric air bubble was performed in 61 (72%) patients. Altogether, 82 (97%) of 85 G tubes were successfully placed in this fashion. The three failures comprised refusal of effervescent, vomiting of effervescent, and one initial tube misplacement when a deviation from our standard technique occurred. Conclusion: The described techniques compare favorably with published large series on G-tube placement with an NG tube in place. The techniques are especially suited for patients with UDTO due to head, neck, or esophageal malignancies, but they should be considered as an alternative in all patients. Direct puncture of effervescent-enhanced gastric bubble distention is a safe, patient-friendly and effective technique.« less

  11. Tube Feeding Troubleshooting Guide

    MedlinePlus

    ... in place. (For example, does it have a balloon, a mushroom bumper, or other internal device, or ... Frequent vomiting. • See “Nausea and Vomiting” page 3. Balloon deflates or bursts. • Be sure the balloon under ...

  12. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., modified or configured for items listed in that category, bomb racks and shackles, bomb shackle release units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and...

  13. Experimental investigation of the draft tube inlet flow of a bulb turbine

    NASA Astrophysics Data System (ADS)

    Vuillemard, J.; Aeschlimann, V.; Fraser, R.; Lemay, S.; Deschênes, C.

    2014-03-01

    In the BulbT project framework, a bulb turbine model was studied with a strongly diverging draft tube. At high discharge, flow separation occurs in the draft tube correlated to significant efficiency and power drops. In this context, a focus was put on the draft tube inlet flow conditions. Actually, a precise inlet flow velocity field is required for comparison and validation purposes with CFD simulation. This paper presents different laser Doppler velocimetry (LDV) measurements at the draft tube inlet and their analysis. The LDV was setup to measure the axial and circumferential velocity on a radius under the runner and a diameter under the hub. A method was developed to perform indirect measurement of the mean radial velocity component. Five operating conditions were studied to correlate the inlet flow to the separation in the draft tube. Mean velocities, fluctuations and frequencies allowed characterizing the flow. Using this experimental database, the flow structure was characterized. Phase averaged velocities based on the runner position allowed detecting the runner blade wakes. The velocity gradients induced by the blade tip vortices were captured. The guide vane wakes was also detected at the draft tube inlet. The recirculation in the hub wake was observed.

  14. Tubing misconnections: normalization of deviance.

    PubMed

    Simmons, Debora; Symes, Lene; Guenter, Peggi; Graves, Krisanne

    2011-06-01

    Accidental connection of an enteral system to an intravenous (IV) system frequently results in the death of the patient. Misconnections are commonly attributed to the presence of universal connectors found in the majority of patient care tubing systems. Universal connectors allow for tubing misconnections between physiologically incompatible systems. The purpose of this review of case studies of tubing misconnections and of current expert recommendations for safe tubing connections was to answer the following questions: In tubing connections that have the potential for misconnections between enteral and IV tubing, what are the threats to safety? What are patient outcomes following misconnections between enteral and IV tubing? What are the current recommendations for preventing misconnections between enteral and IV tubing? Following an extensive literature search and guided by 2 models of threats and errors, the authors analyzed case studies and expert opinions to identify technical, organizational, and human errors; patient-related threats; patient outcomes; and recommendations. A total of 116 case studies were found in 34 publications. Each involved misconnections of tubes carrying feedings, intended for enteral routes, to IV lines. Overwhelmingly, the recommendations were for redesign to eliminate universal connectors and prevent misconnections. Other recommendations were made, but the analysis indicates they would not prevent all misconnections. This review of the published case studies and current expert recommendations supports a redesign of connectors to ensure incompatibility between enteral and IV systems. Despite the cumulative evidence, little progress has been made to safeguard patients from tubing misconnections.

  15. Estimation of optimal nasotracheal tube depth in adult patients.

    PubMed

    Ji, Sung-Mi

    2017-12-01

    The aim of this study was to estimate the optimal depth of nasotracheal tube placement. We enrolled 110 patients scheduled to undergo oral and maxillofacial surgery, requiring nasotracheal intubation. After intubation, the depth of tube insertion was measured. The neck circumference and distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch were measured. To estimate optimal tube depth, correlation and regression analyses were performed using clinical and anthropometric parameters. The mean tube depth was 28.9 ± 1.3 cm in men (n = 62), and 26.6 ± 1.5 cm in women (n = 48). Tube depth significantly correlated with height (r = 0.735, P < 0.001). Distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch correlated with depth of the endotracheal tube (r = 0.363, r = 0.362, and r = 0.546, P < 0.05). The tube depth also correlated with the sum of these distances (r = 0.646, P < 0.001). We devised the following formula for estimating tube depth: 19.856 + 0.267 × sum of the three distances (R 2 = 0.432, P < 0.001). The optimal tube depth for nasotracheally intubated adult patients correlated with height and sum of the distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch. The proposed equation would be a useful guide to determine optimal nasotracheal tube placement.

  16. High Velocity Jet Noise Source Location and Reduction. Task 6. Noise Abatement Nozzle Design Guide.

    DTIC Science & Technology

    1979-04-01

    the Conical Nozzle 255 on the Bertin Aerotrain . xvi ji4 ’ . _______ p .. LIST OF ILLUSTRATIONS (Continued) Figure Page D-37. Predicted and Measured...Moving-Frame Noise from the 256 Conical Nozzle on the Bertin Aerotrain . D-38. Predicted and Measured Static Noise from the 104-Tube 257 Nozzle on the...Bertin Aerotrain . D-39. Predicted and Measured Moving-Frame Noise from the 104- 258 Tube Nozzle on the Bertin Aerotrain . D-40. Relative Velocity Index m

  17. Large volume flow-through scintillating detector

    DOEpatents

    Gritzo, Russ E.; Fowler, Malcolm M.

    1995-01-01

    A large volume flow through radiation detector for use in large air flow situations such as incinerator stacks or building air systems comprises a plurality of flat plates made of a scintillating material arranged parallel to the air flow. Each scintillating plate has a light guide attached which transfers light generated inside the scintillating plate to an associated photomultiplier tube. The output of the photomultiplier tubes are connected to electronics which can record any radiation and provide an alarm if appropriate for the application.

  18. Quantification of cellular penetrative forces using lab-on-a-chip technology and finite element modeling

    PubMed Central

    Sanati Nezhad, Amir; Naghavi, Mahsa; Packirisamy, Muthukumaran; Bhat, Rama; Geitmann, Anja

    2013-01-01

    Tip-growing cells have the unique property of invading living tissues and abiotic growth matrices. To do so, they exert significant penetrative forces. In plant and fungal cells, these forces are generated by the hydrostatic turgor pressure. Using the TipChip, a microfluidic lab-on-a-chip device developed for tip-growing cells, we tested the ability to exert penetrative forces generated in pollen tubes, the fastest-growing plant cells. The tubes were guided to grow through microscopic gaps made of elastic polydimethylsiloxane material. Based on the deformation of the gaps, the force exerted by the elongating tubes to permit passage was determined using finite element methods. The data revealed that increasing mechanical impedance was met by the pollen tubes through modulation of the cell wall compliance and, thus, a change in the force acting on the obstacle. Tubes that successfully passed a narrow gap frequently burst, raising questions about the sperm discharge mechanism in the flowering plants. PMID:23630253

  19. An evaluation of bacterial contamination of barriers used in periapical tissue regeneration: Part 2--Bacterial penetration.

    PubMed

    Sharma, Priya; Mickel, André K; Chogle, Sami; Sharma, Prem Nath; Han, Yiping W; Jones, Jefferson J

    2008-03-01

    To compare the relative penetration of Prevotella melaninogenica and Enterococcus faecalis through 3 guided tissue regeneration membranes: Atrisorb, Lambone, and OsseoQuest. It was hypothesized that OsseoQuest would show increased bacterial penetration when compared to Lambone and Atrisorb. Centrifuge tubes containing trypticase soy broth were sealed with circular sections of membranes and placed in test tubes containing culture media. The bacterial penetration was assessed by passage of bacteria from the outer tube culture media to the inner centrifuge tube media through the membrane. After incubation for 4 and 48 hours, the media from the outer and inner tubes were compared for bacterial count. P melaninogenica exhibited 91% penetration for Lambone in 2 days, while OsseoQuest displayed 87% penetration with E faecalis in the same time. Atrisorb displayed a minimal penetration with both bacteria (2%). Atrisorb displayed the least bacterial penetration, which may be attributed to membrane structure, chemical configuration, hydrophobicity, and porosity of tested membranes.

  20. Head losses prediction and analysis in a bulb turbine draft tube under different operating conditions using unsteady simulations

    NASA Astrophysics Data System (ADS)

    Wilhelm, S.; Balarac, G.; Métais, O.; Ségoufin, C.

    2016-11-01

    Flow prediction in a bulb turbine draft tube is conducted for two operating points using Unsteady RANS (URANS) simulations and Large Eddy Simulations (LES). The inlet boundary condition of the draft tube calculation is a rotating two dimensional velocity profile exported from a RANS guide vane- runner calculation. Numerical results are compared with experimental data in order to validate the flow field and head losses prediction. Velocity profiles prediction is improved with LES in the center of the draft tube compared to URANS results. Moreover, more complex flow structures are obtained with LES. A local analysis of the predicted flow field using the energy balance in the draft tube is then introduced in order to detect the hydrodynamic instabilities responsible for head losses in the draft tube. In particular, the production of turbulent kinetic energy next to the draft tube wall and in the central vortex structure is found to be responsible for a large part of the mean kinetic energy dissipation in the draft tube and thus for head losses. This analysis is used in order to understand the differences in head losses for different operating points. The numerical methodology could then be improved thanks to an in-depth understanding of the local flow topology.

  1. Transfer of a cold atmospheric pressure plasma jet through a long flexible plastic tube

    NASA Astrophysics Data System (ADS)

    Kostov, Konstantin G.; Machida, Munemasa; Prysiazhnyi, Vadym; Honda, Roberto Y.

    2015-04-01

    This work proposes an experimental configuration for the generation of a cold atmospheric pressure plasma jet at the downstream end of a long flexible plastic tube. The device consists of a cylindrical dielectric chamber where an insulated metal rod that serves as high-voltage electrode is inserted. The chamber is connected to a long (up to 4 m) commercial flexible plastic tube, equipped with a thin floating Cu wire. The wire penetrates a few mm inside the discharge chamber, passes freely (with no special support) along the plastic tube and terminates a few millimeters before the tube end. The system is flushed with Ar and the dielectric barrier discharge (DBD) is ignited inside the dielectric chamber by a low frequency ac power supply. The gas flow is guided by the plastic tube while the metal wire, when in contact with the plasma inside the DBD reactor, acquires plasma potential. There is no discharge inside the plastic tube, however an Ar plasma jet can be extracted from the downstream tube end. The jet obtained by this method is cold enough to be put in direct contact with human skin without an electric shock. Therefore, by using this approach an Ar plasma jet can be generated at the tip of a long plastic tube far from the high-voltage discharge region, which provides the safe operation conditions and device flexibility required for medical treatment.

  2. High negative pressure subcutaneous suction drain for managing debilitating subcutaneous emphysema secondary to tube thoracostomy for an iatrogenic post computed tomography guided transthoracic needle biopsy pneumothorax: Case report and review of literature.

    PubMed

    Ahmed, Zeeshan; Patel, Pinakin; Singh, Suresh; Sharma, Raj Govind; Somani, Pankaj; Gouri, Abdul Rauf; Singh, Shiv

    2016-01-01

    Subcutaneous emphysema is a common complication of tube thoracostomy. Though self-limiting, it should be treated when it causes palpebral closure, dyspnea, dysphagia or undue disfigurement resulting in anxiety and distress to the patient. A 72year old man who was a known case of COPD on bronchodilators developed a large pneumothorax and respiratory distress after a CT guided transthoracic lung biopsy done for a lung opacity (approx. 3×3cm) at the right hilar region on Chest X-ray. Within 24h of an urgent tube thoracostomy, patient developed intractable subcutaneous emphysema with closure of palpebral fissure and dyspnea unresponsive to increasing suction on chest tube. A subcutaneous fenestrated drain was placed mid-way between the nipple and clavicle in the mid-clavicular line bilaterally. Continuous negative suction (-150mmHg) resulted in immediate, sustained relief and complete resolution within 5days. Extensive and debilitating SE (subcutaneous emphysema) has to be treated promptly to relieve patient discomfort, dysphagia or imminent respiratory compromise. A variety of treatment have been tried including infraclavicular blow-hole incisions, subcutaneous drains +/- negative pressure suction, fenestrated angiocatheters, Vacuum assisted dressings and increasing suction on a pre-existing chest tube. We describe a high negative pressure subcutaneous suction drain which provides immediate and sustained relief in debilitating SE. Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Management of Pleural Effusion, Empyema, and Lung Abscess

    PubMed Central

    Yu, Hyeon

    2011-01-01

    Pleural effusion is an accumulation of fluid in the pleural space that is classified as transudate or exudate according to its composition and underlying pathophysiology. Empyema is defined by purulent fluid collection in the pleural space, which is most commonly caused by pneumonia. A lung abscess, on the other hand, is a parenchymal necrosis with confined cavitation that results from a pulmonary infection. Pleural effusion, empyema, and lung abscess are commonly encountered clinical problems that increase mortality. These conditions have traditionally been managed by antibiotics or surgical placement of a large drainage tube. However, as the efficacy of minimally invasive interventional procedures has been well established, image-guided small percutaneous drainage tubes have been considered as the mainstay of treatment for patients with pleural fluid collections or a lung abscess. In this article, the technical aspects of image-guided interventions, indications, expected benefits, and complications are discussed and the published literature is reviewed. PMID:22379278

  4. Spent nuclear fuel system dynamic stability under normal conditions of transportation

    DOE PAGES

    Jiang, Hao; Wang, Jy-An John

    2016-10-14

    In a horizontal layout of a spent nuclear fuel (SNF) assembly under normal conditions of transportation (NCT), the fuel assembly’s skeleton formed by guide tubes and spacer grids is the primary load bearing structure for carrying and transferring the vibration loads within an SNF assembly. Therefore, the integrity of guide tubes and spacer grids will dictate the vibration amplitude/intensity of the fuel assembly during transport, and must be considered when designing multipurpose purpose canister (MPC) for safe SNF transport. This paper investigates the SNF assembly deformation dynamics during normal vibration mode, as well as the transient shock mode inside themore » cask during NCT. In conclusion, dynamic analyses were performed in the frequency domain to study frequency characteristic of the fuel assembly system and in the time domain to simulate the transient dynamic response of the fuel assembly.« less

  5. Spent nuclear fuel system dynamic stability under normal conditions of transportation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Hao; Wang, Jy-An John

    In a horizontal layout of a spent nuclear fuel (SNF) assembly under normal conditions of transportation (NCT), the fuel assembly’s skeleton formed by guide tubes and spacer grids is the primary load bearing structure for carrying and transferring the vibration loads within an SNF assembly. Therefore, the integrity of guide tubes and spacer grids will dictate the vibration amplitude/intensity of the fuel assembly during transport, and must be considered when designing multipurpose purpose canister (MPC) for safe SNF transport. This paper investigates the SNF assembly deformation dynamics during normal vibration mode, as well as the transient shock mode inside themore » cask during NCT. In conclusion, dynamic analyses were performed in the frequency domain to study frequency characteristic of the fuel assembly system and in the time domain to simulate the transient dynamic response of the fuel assembly.« less

  6. Oral to nasal tube exchange under fibroscopic view: a new technique for nasal intubation in a predicted difficult airway.

    PubMed

    Monclus, Enric; Garcés, Antonio; Artés, David; Mabrock, Maged

    2008-07-01

    For a predicted difficult airway, oral intubation techniques are well established in pediatric anesthesia, but nasotracheal intubation remains a problem. There are many reports concerning this, but the risk of bleeding, added to the lack of cooperation make this procedure difficult and hazardous. We describe a modification of the nasal intubation technique in two stages. First an oral intubation and then exchanging the oral for a nasal tube, in the case of a 13-year-old boy affected by an advanced stage of cherubism. Oral intubation using a laryngeal mask technique has already been reported, but problems appear during the exchange procedure and even more when direct laryngoscopy is impossible. Fiberscopic control of the exchange, and the introduction of a Cook Exchange Catheter into the trachea through the oral tube before withdrawal, permits oxygenation of the patient and acts as a guide for oral tube reintroduction if required.

  7. Emergency cricothyrotomy-a comparative study of different techniques in human cadavers.

    PubMed

    Schober, Patrick; Hegemann, Martina C; Schwarte, Lothar A; Loer, Stephan A; Noetges, Peter

    2009-02-01

    Emergency cricothyrotomy is the final lifesaving option in "cannot intubate-cannot ventilate" situations. Fast, efficient and safe management is indispensable to reestablish oxygenation, thus the quickest, most reliable and safest technique should be used. Several cricothyrotomy techniques exist, which can be grouped into two categories: anatomical-surgical and puncture. We studied success rate, tracheal tube insertion time and complications of different techniques, including a novel cricothyrotomy scissors technique in human cadavers. Sixty-three inexperienced health care providers were randomly assigned to apply either an anatomical-surgical technique (standard surgical technique, n=18; novel cricothyrotomy scissors technique, n=14) or a puncture technique (catheter-over-needle technique, n=17; wire-guided technique, n=14). Airway access was almost always successful with the anatomical-surgical techniques (success rate in standard surgical group 94%, scissors group 100%). In contrast, the success rate was smaller (p<0.05) with the puncture techniques (catheter-over-needle group 82%, wire-guided technique 71%). Tracheal tube insertion time was faster overall (p<0.05) with anatomical-surgical techniques (standard surgical 78s [54-135], novel cricothyrotomy scissors technique 60s [42-82]; median [IQR]) than with puncture techniques (catheter-over-needle technique 74s [48-145], wire-guided technique 135s [116-307]). We observed fewer complications with anatomical-surgical techniques than with puncture techniques (p<0.001). In inexperienced health care personnel, anatomical-surgical techniques showed a higher success rate, a faster tracheal tube insertion time and a lower complication rate compared with puncture techniques, suggesting that they may be the techniques of choice in emergencies.

  8. Techniques for the insertion of the ProSeal laryngeal mask airway: comparison of the Foley airway stylet tool with the introducer tool in a prospective, randomized study.

    PubMed

    Chen, Mao-Kai; Hsu, Hung-Te; Lu, I-Cheng; Shih, Chih-Kai; Shen, Ya-Chun; Tseng, Kuang-Yi; Cheng, Kuang-I

    2014-01-01

    Many tools have been developed to facilitate the insertion of the ProSeal laryngeal mask airway (LMA) insertion, which can be impeded by folding of its soft cuff. The aim of this study was to compare the efficiency of ProSeal LMA insertion guided by a soft, direct optical Foley Airway Stylet Tool (FAST) with the standard introducer tool (IT). One hundred sixty patients undergoing general anesthesia using the ProSeal LMA as an airway management device were randomly allocated to either FAST-guided or IT-assisted groups. Following ProSeal LMA insertion, the glottic and esophageal openings were identified using a fiberoptic bronchoscope introduced through the airway and the drain tube. The primary outcomes were time taken to insert the ProSeal LMA and the success rate at the first attempt. Secondary end points included ease of insertion, hemodynamic response to insertion, and postoperative adverse events recorded in the recovery room and on the first postoperative morning. One hundred forty patients were included in the final analysis: 66 in the FAST-guided group and 74 in the IT-assisted group. The success rate of FAST device-guided ProSeal LMA insertion (95.7%) was broadly comparable with IT-assisted insertion (98.7%). However, the time taken to insert the ProSeal LMA was significantly longer when the FAST technique was used (p <0.001). The incidence of correct alignment of the airway tube and the drain tube did not differ significantly between the groups. There were no significant differences in ease of insertion or hemodynamic responses to insertion, except that the incidence of postoperative sore throat was significantly higher in the FAST group on the first postoperative day (22.2% compared with 6.8% in the IT group; p = 0.035). Both FAST-guided and IT-assisted techniques achieved correct ProSeal LMA positioning, but the IT technique was significantly quicker and less likely to cause a sore throat. ClinicalTrials.gov Identifier: NCT02048657.

  9. Patient's Guide to Aerosol Drug Delivery

    MedlinePlus

    ... nebulizer. Ultrasonic nebulizers should be cleaned and disinfected based on the manu- facturer’s recommendations. Table 12. Cleaning instructions for the jet nebulizer CLEANING AFTER EACH USE Wash your hands before handling equipment. Disassemble parts after every treatment. Remove the tubing ...

  10. Measurements of shock-induced guided and surface acoustic waves along boreholes in poroelastic materials

    NASA Astrophysics Data System (ADS)

    Chao, Gabriel; Smeulders, D. M. J.; van Dongen, M. E. H.

    2006-05-01

    Acoustic experiments on the propagation of guided waves along water-filled boreholes in water-saturated porous materials are reported. The experiments were conducted using a shock tube technique. An acoustic funnel structure was placed inside the tube just above the sample in order to enhance the excitation of the surface modes. A fast Fourier transform-Prony-spectral ratio method is implemented to transform the data from the time-space domain to the frequency-wave-number domain. Frequency-dependent phase velocities and attenuation coefficients were measured using this technique. The results for a Berea sandstone material show a clear excitation of the fundamental surface mode, the pseudo-Stoneley wave. The comparison of the experimental results with numerical predictions based on Biot's theory of poromechanics [J. Acoust. Soc. Am. 28, 168 (1956)], shows that the oscillating fluid flow at the borehole wall is the dominant loss mechanism governing the pseudo-Stoneley wave and it is properly described by the Biot's model at frequencies below 40 kHz. At higher frequencies, a systematic underestimation of the theoretical predictions is found, which can be attributed to the existence of other losses mechanisms neglected in the Biot formulation. Higher-order guided modes associated with the compressional wave in the porous formation and the cylindrical geometry of the shock tube were excited, and detailed information was obtained on the frequency-dependent phase velocity and attenuation in highly porous and permeable materials. The measured attenuation of the guided wave associated with the compressional wave reveals the presence of regular oscillatory patterns that can be attributed to radial resonances. This oscillatory behavior is also numerically predicted, although the measured attenuation values are one order of magnitude higher than the corresponding theoretical values. The phase velocities of the higher-order modes are generally well predicted by theory.

  11. Unique stigmatic hairs and pollen-tube growth within the stigmatic cell wall in the early-divergent angiosperm family Hydatellaceae

    PubMed Central

    Prychid, Christina J.; Sokoloff, Dmitry D.; Remizowa, Margarita V.; Tuckett, Renee E.; Yadav, Shrirang R.; Rudall, Paula J.

    2011-01-01

    Background and Aims The ultrastructure of the pollen tubes and the unusual multicellular stigmatic hairs of Trithuria, the sole genus of Hydatellaceae, are described in the context of comparative studies of stigmatic and transmitting tissue in other early-divergent angiosperms. Methods Scanning and transmission electron microscopy and immunocytochemistry are used to study the structure and composition of both mature and immature stigmatic hair cells and pollen-tube growth in Trithuria. Key Results Trithuria possesses a dry-type stigma. Pollen tubes grow within the cell walls of the long multicellular stigmatic hairs. Immunocytochemistry results suggest that arabinogalactan proteins are involved in attracting the pollen tubes through the stigmatic cuticle. Most tubes grow along the hair axis towards its base, but some grow towards the hair apex, suggesting that pollen tubes are guided by both physical constraints such as microfibril orientation and the presence of binding factors such as unesterified pectins and adhesive proteins. Conclusions The presence of a dry-type stigma in Trithuria supports the hypothesis that this condition is ancestral in angiosperms. Each multicellular stigmatic hair of Hydatellaceae is morphologically homologous with a stigmatic papilla of other angiosperms, but functions as an independent stigma and style. This unusual combination of factors makes Hydatellaceae a useful model for comparative studies of pollen-tube growth in early angiosperms. PMID:21320877

  12. Development of a hydro kinetic river turbine with simulation and operational measurement results in comparison

    NASA Astrophysics Data System (ADS)

    Ruopp, A.; Ruprecht, A.; Riedelbauch, S.; Arnaud, G.; Hamad, I.

    2014-03-01

    The development of a hydro-kinetic prototype was shown including the compound structure, guide vanes, runner blades and a draft tube section with a steeply sloping, short spoiler. The design process of the hydrodynamic layout was split into three major steps. First the compound and the draft tube section was designed and the best operating point was identified using porous media as replacement for the guide vane and runner section (step one). The best operating point and the volume flux as well as the pressure drop was identified and used for the design of the guide vane section and the runner section. Both were designed and simulated independently (step two). In step three, all parts were merged in stationary simulation runs detecting peak power and operational bandwidth. In addition, the full scale demonstrator was installed in August 2010 and measured in the St. Lawrence River in Quebec supporting the average inflow velocity using ADCP (Acoustic Doppler Current Profiler) and the generator power output over the variable rotational speed. Simulation data and measurements are in good agreement. Thus, the presented approach is a suitable way in designing a hydro kinetic turbine.

  13. Phased laser diode array permits selective excitation of ultrasonic guided waves in coated bone-mimicking tubes

    NASA Astrophysics Data System (ADS)

    Moilanen, Petro; Salmi, Ari; Kilappa, Vantte; Zhao, Zuomin; Timonen, Jussi; Hæggström, Edward

    2017-10-01

    This paper validates simulation predictions, which state that specific modes could be enhanced in quantitative ultrasonic bone testing. Tunable selection of ultrasonic guided wave excitation is useful in non-destructive testing since it permits the mediation of energy into diagnostically useful modes while reducing the energy mediated into disturbing contributions. For instance, it is often challenging to distinguish and extract the useful modes from ultrasound signals measured in bone covered by a soft tissue. We show that a laser diode array can selectively excite ultrasound in bone mimicking phantoms. A fiber-coupled diode array (4 elements) illuminated two solid tubes (2-3 mm wall thickness) embraced by an opaque soft-tissue mimicking elastomer coating (5 mm thick). A predetermined time delay matching the selected mode and frequency was employed between the outputs of the elements. The generated ultrasound was detected by a 215 kHz piezo receiver. Our results suggest that this array reduces the disturbances caused by the elastomer cover and so pave way to permit non-contacting in vivo guided wave ultrasound assessment of human bones. The implementation is small, inexpensive, and robust in comparison with the conventional pulsed lasers.

  14. Ultrasonic guided waves in eccentric annular pipes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pattanayak, Roson Kumar; Balasubramaniam, Krishnan; Rajagopal, Prabhu

    2014-02-18

    This paper studies the feasibility of using ultrasonic guided waves to rapidly inspect tubes and pipes for possible eccentricity. While guided waves are well established in the long range inspection of structures such as pipes and plates, studies for more complex cross sections are limited and analytical solutions are often difficult to obtain. Recent developments have made the Semi Analytical Finite Element (SAFE) method widely accessible for researchers to study guided wave properties in complex structures. Here the SAFE method is used to study the effect of eccentricity on the modal structures and velocities of lower order guided wave modesmore » in thin pipes of diameters typically of interest to the industry. Results are validated using experiments. The paper demonstrates that even a small eccentricity in the pipe can strongly affect guided wave mode structures and velocities and hence shows potential for pipe eccentricity inspection.« less

  15. User's guide for a large signal computer model of the helical traveling wave tube

    NASA Technical Reports Server (NTRS)

    Palmer, Raymond W.

    1992-01-01

    The use is described of a successful large-signal, two-dimensional (axisymmetric), deformable disk computer model of the helical traveling wave tube amplifier, an extensively revised and operationally simplified version. We also discuss program input and output and the auxiliary files necessary for operation. Included is a sample problem and its input data and output results. Interested parties may now obtain from the author the FORTRAN source code, auxiliary files, and sample input data on a standard floppy diskette, the contents of which are described herein.

  16. Structural parameters of collagen nerve grafts influence peripheral nerve regeneration.

    PubMed

    Stang, Felix; Fansa, Hisham; Wolf, Gerald; Reppin, Michael; Keilhoff, Gerburg

    2005-06-01

    Large nerve defects require nerve grafts to allow regeneration. To avoid donor nerve problems the concept of tissue engineering was introduced into nerve surgery. However, non-neuronal grafts support axonal regeneration only to a certain extent. They lack viable Schwann cells which provide neurotrophic and neurotopic factors and guide the sprouting nerve. This experimental study used the rat sciatic nerve to bridge 2 cm nerve gaps with collagen (type I/III) tubes. The tubes were different in their physical structure (hollow versus inner collagen skeleton, different inner diameters). To improve regeneration Schwann cells were implanted. After 8 weeks the regeneration process was monitored clinically, histologically and morphometrically. Autologous nerve grafts and collagen tubes without Schwann cells served as control. In all parameters autologous nerve grafts showed best regeneration. Nerve regeneration in a noteworthy quality was also seen with hollow collagen tubes and tubes with reduced lumen, both filled with Schwann cells. The inner skeleton, however, impaired nerve regeneration independent of whether Schwann cells were added or not. This indicates that not only viable Schwann cells are an imperative prerequisite but also structural parameters determine peripheral nerve regeneration.

  17. Family Experiences With Feeding Tubes in Neurologic Impairment: A Systematic Review.

    PubMed

    Nelson, Katherine E; Lacombe-Duncan, Ashley; Cohen, Eyal; Nicholas, David B; Rosella, Laura C; Guttmann, Astrid; Mahant, Sanjay

    2015-07-01

    Gastrostomy tubes (G-tubes) are frequently used to provide enteral nutrition for children who have neurologic impairment. Understanding the impact of G-tubes from the family's perspective will inform decision-making and improve support from health care providers. This study explored the experiences of families after G-tube placement in children with neurologic impairment. We conducted a systematic review of English-language qualitative primary research studies describing family experiences after G-tube placement. Six electronic databases were searched from inception to June 2014. Two authors independently screened and identified relevant studies, evaluated quality of reporting by using the Consolidated Criteria for Reporting Qualitative Research tool, and extracted data. Overarching concepts were developed by using thematic analysis. From 2674 screened abstracts, 84 texts were reviewed, and 13 studies met the inclusion criteria. G-tubes affect the lives of children, parents, and the family unit in many ways, both positive and negative. Improvements and challenges were described for children's health and happiness, for parental caregiving and stress, and for logistics and bonding within the family. G-tube feeding also changed relationships within the family, between the family and the medical system, and between the family and the outside world. Furthermore, experiences varied, with different families framing similar concepts as positive and negative. G-tube placement has diverse effects on daily life for children with neurologic impairment and their families. Clinicians may use the themes identified in this study to guide conversations with families about their values, experiences, and expectations before and after G-tube placement. Copyright © 2015 by the American Academy of Pediatrics.

  18. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    PubMed

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  19. [Use of Airwayscope with pediatric intlock in a patient with first and second branchial arch syndrome].

    PubMed

    Kubota, Aiko; Takeda, Akiko; Arai, Toshimi; Murozono, Michihiro

    2013-12-01

    First and second branchial arch syndrome is a congenital anomaly of craniofacial dysplasia involving organs derived from the second branchial arch. The main characteristics are microtia and mandibular hypoplasia. A 6-year-old boy was scheduled for adenoidectomy and bilateral myringotomy and tube placement. Slow induction was performed with oxygen, nitrous oxide, and sevoflurane. No difficulties were encountered during mask ventilation, and rocuronium was administered intravenously. His epiglottis was not visible during laryngoscopy. Therefore, we used the Airwayscope (AWS). His glottis was visible after application of cricold pressure from the left side. However, we could not closely conform his epiglottis to the mark on the AWS. Therefore, we passed a fiberoptic bronchoscope through a tracheal tube and placed it in the AWS. We attempted to intubate the trachea, but could not guide the bronchoscope to his glottis. We then attempted to pull the tracheal tube to improve the mobility of the bronchoscope. Control of the bronchoscope consequently became easy We successfully guided it to his glottis and performed tracheal intubation. His condition was stable during the procedure. In conclusion, we safely performed tracheal intubation in a patient with first and second branchial arch syndrome using the AWS and a fiberoptic bronchoscope.

  20. Unsteady numerical simulation of the flow in the U9 Kaplan turbine model

    NASA Astrophysics Data System (ADS)

    Javadi, Ardalan; Nilsson, Håkan

    2014-03-01

    The Reynolds-averaged Navier-Stokes equations with the RNG k-ε turbulence model closure are utilized to simulate the unsteady turbulent flow throughout the whole flow passage of the U9 Kaplan turbine model. The U9 Kaplan turbine model comprises 20 stationary guide vanes and 6 rotating blades (696.3 RPM), working at best efficiency load (0.71 m3/s). The computations are conducted using a general finite volume method, using the OpenFOAM CFD code. A dynamic mesh is used together with a sliding GGI interface to include the effect of the rotating runner. The clearance is included in the guide vane. The hub and tip clearances are also included in the runner. An analysis is conducted of the unsteady behavior of the flow field, the pressure fluctuation in the draft tube, and the coherent structures of the flow. The tangential and axial velocity distributions at three sections in the draft tube are compared against LDV measurements. The numerical result is in reasonable agreement with the experimental data, and the important flow physics close to the hub in the draft tube is captured. The hub and tip vortices and an on-axis forced vortex are captured. The numerical results show that the frequency of the forced vortex in 1/5 of the runner rotation.

  1. Theoretical solution for light transmission of a bended hollow light guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kocifaj, Miroslav; Darula, Stanislav; Kittler, Richard

    2010-08-15

    Hollow light guides with very high reflective inner surfaces are novel daylight systems that collect sunlight and skylight available on the roof of buildings transporting it into deep or windowless interiors in building cores. Thus the better utilization of daylight can result in energy savings and wellbeing in these enclosed indoor spaces. An analytical complex solution of a straight tube system was solved in the HOLIGILM method with a user-friendly tool available on the http://www.holigilm.info. An even more difficult light flow transport is to be determined in bended tubes usually placed on sloped roofs where a bend is necessary tomore » adjust the vertical pass through the ceilings. This paper presents the theoretical derivation of the model with its graphical representation and coordinate system respecting backward ray-tracing bend distortions. To imagine the resulting illuminance on the horizontal plane element in the interior, the virtual ray (i.e. luminance in an elementary solid angle) has to pass the ceiling diffuser interface, the inner mirror like tube with a bend, through a roof cupola attachment to the element of the sky and sun light source. Due to this complexity and the lengthy derivation and explanations more practical applications will be published later in a separate contribution. (author)« less

  2. Tracheopleuropulmonary injuries following enteral tube insertion.

    PubMed Central

    Odocha, O.; Lowery, R. C.; Mezghebe, H. M.; Siram, S. M.; Warner, O. G.

    1989-01-01

    Eighty-three cases of tracheopleuropulmonary injuries complicating enteral tube feeding are analyzed to identify the patterns of injury, and precipitating factors and ways to avoid them. Six new cases observed by the authors and 77 other cases cited in British literature between 1976 and 1987 are presented. In recent years, reports of this complication have been increasing, apparently in a geometrical progression: 8%, 18%, and 74% were reported between 1976 to 1979, 1980 to 1983, and 1984 to 1987, respectively. Sixty-one percent occurred in patients aged 60 years or older. Most of the patients (84%) were seriously ill, which compounded their complications. Seventy-four percent of all injuries were committed by house staff; the narrow bore tube with guide wire was used in 77% of cases. Less than reliable methods were used to confirm tube position in most instances. The presence of cuffed endotracheal tubes did not offer protection. The patients on mechanical ventilation tended to deteriorate if they developed a pneumothorax once the malpositioned tubes were removed. Of the cases reviewed for this report, 18 deaths occurred; 72% being directly related to the tube injuries. Lack of awareness, inadequate confirmatory methods, and insufficient supervision accounted for most of these preventable complications. Educating house/nursing staff in the use of the new tubes, closer supervision, and the application of equal measures of care and caution as employed in other invasive and potentially dangerous procedures are recommended to avoid disastrous outcome. PMID:2496234

  3. Hydroball string sensing system

    DOEpatents

    Hurwitz, Michael J.; Ekeroth, Douglas E.; Squarer, David

    1991-01-01

    A hydroball string sensing system for a nuclear reactor that includes stainless tubes positioned to guide hydroball strings into and out of the nuclear reactor core. A sensor such as an ultrasonic transducer transmitter and receiver is positioned outside of the nuclear reactor core and adjacent to the tube. The presence of an object such a bullet member positioned at an end a hydroball string, or any one of the hydroballs interrupts the transmission of ultrasound from the transmitter to the receiver. Alternatively, if the bullet member and hydroballs include a ferritic material, either a Hall effect sensor or other magnetic field sensors such as a magnetic field rate of change sensor can be used to detect the location and position of a hydroball string. Placing two sensors along the tube with a known distance between the sensors enables the velocity of a hydroball string to be determined. This determined velocity can be used to control the flow rate of a fluid within the tube so as to control the velocity of the hydroball string.

  4. The heart of the matter: from guided microtools to 3-D printing and precision genome editing, promising research could lead to new advances in pediatric cardiology.

    PubMed

    Chandler, David L

    2015-01-01

    The smooth, powerful muscles of a newborn baby?s heart are pulsing normally, squeezing in and letting go rhythmically as a 3-mm-wide catheter-like tube snakes its way through, entering via an artery and being guided slowly by a surgeon. When it reaches its target?a protruding knot of malformed muscle tissue within a ventricle that has been partly blocking the valve?the tip of the precisely controlled tube whirs into action, with tiny scissor-like rotating blades gently grinding up the excess tissue as those pieces are sucked back into the device, leaving no floating particles that could lead to a blockage elsewhere. The defect is fully removed, and the heart?s function is restored to normal, leaving the child with the prospect of a normal life. The whole minimally invasive process takes place inside a beating heart and would otherwise have required open-heart surgery, with the heart stopped for a cardiopulmonary bypass.

  5. Development of a flexible γ-ray detector using a liquid scintillation light guide (LSLG).

    PubMed

    Nomura, Kiyoshi; Yunoki, Akira; Hara, Masayuki; Morito, Yuko; Fujishima, Akira

    2018-04-10

    A flexible γ detector using a liquid scintillation light guide (LSLG) was developed. The analyzed pulse height (PHA) spectrum depended on the diameter, length and scintillator concentration of the LSLG, and the distance of a γ ray irradiation point from the head of photomultiplier tube (PMT). From the analysis of PHA spectrum, it was found that the count ratio of two divided channel regions linearly decreases as the distance from the PMT head increases. It was further found that the radiation dose rate can be estimated by setting the flexible LSLG tube to a circular shape since the count rate is proportional to the dose rate measured by a conventional NaI (Tl) scintillation detector. Therefore, a flexible and long LSLG detector using a single PMT is useful for determination of the dose rate and has a potential to detect local contaminations in a certain narrow space. Copyright © 2018. Published by Elsevier Ltd.

  6. Feasibility study of superconducting LSM rocket launcher system

    NASA Technical Reports Server (NTRS)

    Yoshida, Kinjiro; Ohashi, Takaaki; Shiraishi, Katsuto; Takami, Hiroshi

    1994-01-01

    A feasibility study is presented concerning an application of a superconducting linear synchronous motor (LSM) to a large-scale rocket launcher, whose acceleration guide tube of LSM armature windings is constructed 1,500 meters under the ground. The rocket is released from the linear launcher just after it gets to a peak speed of about 900 kilometers per hour, and it flies out of the guide tube to obtain the speed of 700 kilometers per hour at the height of 100 meters above ground. The linear launcher is brought to a stop at the ground surface for a very short time of 5 seconds by a quick control of deceleration. Very large current variations in the single-layer windings of the LSM armature, which are produced at the higher speed region of 600 to 900 kilometers per hour, are controlled successfully by adopting the double-layer windings. The proposed control method makes the rocket launcher ascend stably in the superconducting LSM system, controlling the Coriolis force.

  7. Biochemical and Immunocytological Characterizations of Arabidopsis Pollen Tube Cell Wall1[C][W][OA

    PubMed Central

    Dardelle, Flavien; Lehner, Arnaud; Ramdani, Yasmina; Bardor, Muriel; Lerouge, Patrice; Driouich, Azeddine; Mollet, Jean-Claude

    2010-01-01

    During plant sexual reproduction, pollen germination and tube growth require development under tight spatial and temporal control for the proper delivery of the sperm cells to the ovules. Pollen tubes are fast growing tip-polarized cells able to perceive multiple guiding signals emitted by the female organ. Adhesion of pollen tubes via cell wall molecules may be part of the battery of signals. In order to study these processes, we investigated the cell wall characteristics of in vitro-grown Arabidopsis (Arabidopsis thaliana) pollen tubes using a combination of immunocytochemical and biochemical techniques. Results showed a well-defined localization of cell wall epitopes. Low esterified homogalacturonan epitopes were found mostly in the pollen tube wall back from the tip. Xyloglucan and arabinan from rhamnogalacturonan I epitopes were detected along the entire tube within the two wall layers and the outer wall layer, respectively. In contrast, highly esterified homogalacturonan and arabinogalactan protein epitopes were found associated predominantly with the tip region. Chemical analysis of the pollen tube cell wall revealed an important content of arabinosyl residues (43%) originating mostly from (1→5)-α-l-arabinan, the side chains of rhamnogalacturonan I. Finally, matrix-assisted laser desorption ionization time-of-flight mass spectrometry analysis of endo-glucanase-sensitive xyloglucan showed mass spectra with two dominant oligosaccharides (XLXG/XXLG and XXFG), both being mono O-acetylated, and accounting for over 68% of the total ion signals. These findings demonstrate that the Arabidopsis pollen tube wall has its own characteristics compared with other cell types in the Arabidopsis sporophyte. These structural features are discussed in terms of pollen tube cell wall biosynthesis and growth dynamics. PMID:20547702

  8. Biochemical and immunocytological characterizations of Arabidopsis pollen tube cell wall.

    PubMed

    Dardelle, Flavien; Lehner, Arnaud; Ramdani, Yasmina; Bardor, Muriel; Lerouge, Patrice; Driouich, Azeddine; Mollet, Jean-Claude

    2010-08-01

    During plant sexual reproduction, pollen germination and tube growth require development under tight spatial and temporal control for the proper delivery of the sperm cells to the ovules. Pollen tubes are fast growing tip-polarized cells able to perceive multiple guiding signals emitted by the female organ. Adhesion of pollen tubes via cell wall molecules may be part of the battery of signals. In order to study these processes, we investigated the cell wall characteristics of in vitro-grown Arabidopsis (Arabidopsis thaliana) pollen tubes using a combination of immunocytochemical and biochemical techniques. Results showed a well-defined localization of cell wall epitopes. Low esterified homogalacturonan epitopes were found mostly in the pollen tube wall back from the tip. Xyloglucan and arabinan from rhamnogalacturonan I epitopes were detected along the entire tube within the two wall layers and the outer wall layer, respectively. In contrast, highly esterified homogalacturonan and arabinogalactan protein epitopes were found associated predominantly with the tip region. Chemical analysis of the pollen tube cell wall revealed an important content of arabinosyl residues (43%) originating mostly from (1-->5)-alpha-L-arabinan, the side chains of rhamnogalacturonan I. Finally, matrix-assisted laser desorption ionization time-of-flight mass spectrometry analysis of endo-glucanase-sensitive xyloglucan showed mass spectra with two dominant oligosaccharides (XLXG/XXLG and XXFG), both being mono O-acetylated, and accounting for over 68% of the total ion signals. These findings demonstrate that the Arabidopsis pollen tube wall has its own characteristics compared with other cell types in the Arabidopsis sporophyte. These structural features are discussed in terms of pollen tube cell wall biosynthesis and growth dynamics.

  9. Endoscopic placement of Jones lacrimal tubes with the assistance of holmium YAG laser.

    PubMed

    Boboridis, Kostas G; Downes, Richard N

    2005-06-01

    The aim of this paper is to highlight the use of the Holmium YAG laser in the endoscopic placement of Lester Jones tubes in patients with a blocked canaliculus or failed lacrimal pump function. Sixteen cases with a non-functional canaliculus were included over a one-year period. Following caruncle excision, a 19 G needle is inserted through the medial canthal tissues into the nasal space. Nasal endoscopy confirms the accurate positioning in relation to the nasal anatomy. With the Holmium YAG laser, a tissue channel is fashioned around the guide needle through the structures of the lateral nasal wall to facilitate an accurate and secure placement of the Jones tube. The endoscopic, laser-assisted placement reduces the operating time to less than 20 minutes, minimizes tissue trauma and does not require the initial surgical steps of an open DCR procedure. There were 14 cases (87.5%) with securely retained tubes and two cases (12.5%) that required tube replacement. The advantage of the procedure is especially great in revision surgery where the ostium is opened through scar tissue. Nasal endoscopy with the assistance of the Holmium YAG laser offers simplicity and precision in the placement of Jones tubes. It minimizes tissue trauma and increases the surgical success rate.

  10. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D.

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneousmore » image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.« less

  11. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    PubMed

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. Study of light backgrounds from relativistic electrons in air light-guides

    NASA Astrophysics Data System (ADS)

    Riordan, S.; Zhao, Y. X.; Baunack, S.; Becker, D.; Clarke, C.; Dehmelt, K.; Deshpande, A.; Gericke, M.; Gläser, B.; Imai, K.; Kutz, T.; Maas, F. E.; McNulty, D.; Pan, J.; Park, S.; Rahman, S.; Souder, P. A.; Wang, P.; Wellman, B.; Kumar, K. S.

    2018-07-01

    The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Møller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the Møller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.

  13. Upper internals arrangement for a pressurized water reactor

    DOEpatents

    Singleton, Norman R; Altman, David A; Yu, Ching; Rex, James A; Forsyth, David R

    2013-07-09

    In a pressurized water reactor with all of the in-core instrumentation gaining access to the core through the reactor head, each fuel assembly in which the instrumentation is introduced is aligned with an upper internals instrumentation guide-way. In the elevations above the upper internals upper support assembly, the instrumentation is protected and aligned by upper mounted instrumentation columns that are part of the instrumentation guide-way and extend from the upper support assembly towards the reactor head in hue with a corresponding head penetration. The upper mounted instrumentation columns are supported laterally at one end by an upper guide tube and at the other end by the upper support plate.

  14. Effects of Pump-turbine S-shaped Characteristics on Transient Behaviours: Experimental Investigation

    NASA Astrophysics Data System (ADS)

    Zeng, Wei; Yang, Jiandong; Hu, Jinhong; Tang, Renbo

    2017-05-01

    A pumped storage stations model was set up and introduced in the previous paper. In the model station, the S-shaped characteristic curves was measured at the load rejection condition with the guide vanes stalling. Load rejection tests where guide-vane closed linearly were performed to validate the effect of the S-shaped characteristics on hydraulic transients. Load rejection experiments with different guide vane closing schemes were also performed to determine a suitable scheme considering the S-shaped characteristics. The condition of one pump turbine rejecting its load after another defined as one-after-another (OAA) load rejection was performed to validate the possibility of S-induced extreme draft tube pressure.

  15. Three-finger tracheal palpation to guide endotracheal tube depth in children.

    PubMed

    Gamble, Jonathan J; McKay, William P; Wang, Andrew F; Yip, Kinsha A; O'Brien, Jennifer M; Plewes, Christopher E

    2014-10-01

    Accurate endotracheal tube (ETT) depth is critical, especially in children. The current tools used to guide appropriate ETT depth have significant limitations. To evaluate the utility of tracheal palpation in the neck to guide appropriate ETT placement in children. A prospective observational study with a convenience sample of 50 children was conducted. During intubation, an investigator palpated the trachea with three fingertips side-by-side extending upward from the suprasternal notch. The anesthesiologist advanced the ETT slowly until palpated at the sternal notch. The investigator stated ETT palpation certainty as 'strongly felt', 'weakly felt', or 'not felt.' Final ETT position was determined by bronchoscopy and categorized as 'ETT too shallow' (tip in proximal ¼ of trachea), 'ETT too deep' (tip in distal ¼ of trachea), or 'ETT placement satisfactory' (between those extremes). Thirty boys and 20 girls undergoing dental surgery with nasal intubation were recruited (median age 4.4 years; range 2.0-10.8). The ETT (all ≥4 mm ID) was palpable at the sternal notch in all patients: 46 of 50 strongly palpable and 4 of 50 weakly palpable. The experimental methods led to satisfactory ETT placement in 49 of 50 patients, too deep in 1 of 50 patients. Compared with the Pediatrics Advanced Life Support (PALS) predictive formula, satisfactory placement would have been 41 of 50 patients (P < 0.008). Number needed to treat is 6.3 for improvement over the PALS method. The use of tracheal palpation to guide ETT placement has excellent clinical performance and better guides appropriate ETT depth than the PALS formula in our study population. © 2014 John Wiley & Sons Ltd.

  16. Current microbiology of percutaneous endoscopic gastrostomy tube (PEG tube) insertion site infections in patients with cancer.

    PubMed

    Rolston, Kenneth V I; Mihu, Coralia; Tarrand, Jeffrey J

    2011-08-01

    Percutaneous endoscopic gastrostomy (PEG) is frequently used to provide enteral access in cancer patients who are unable to swallow. Infection is an important complication in this setting. Current microbiological data are needed to guide infection prevention and treatment strategies. The microbiological records of our institution (a 550-bed comprehensive cancer center) were retrospectively reviewed over an 8-month study period in order to identify patients who developed PEG tube insertion site infections, and review their microbiological details and susceptibility/resistance data. Fifty-eight episodes of PEG tube insertion site infections were identified. Of these, 31 (53%) were monomicrobial, and the rest were polymicrobial. The most common organisms isolated were Candida species, Staphylococcus aureus, and Pseudomonas aeruginosa. All infections were local (cellulitis, complicated skin, and skin structure infections including abdominal wall abscess) with no cases of concomitant bacteremia being documented. Most of the organisms isolated were susceptible to commonly used antimicrobial agents, although some quinolone-resistant and some multidrug-resistant organisms were isolated. This retrospective study provides descriptive data regarding PEG tube insertion site infections. These data have helped us update institutional guidelines for infection prevention and treatment as part of our focus on antimicrobial stewardship.

  17. Modeling of second-harmonic generation of circumferential guided wave propagation in a composite circular tube

    NASA Astrophysics Data System (ADS)

    Li, Mingliang; Deng, Mingxi; Gao, Guangjian; Xiang, Yanxun

    2018-05-01

    This paper investigated modeling of second-harmonic generation (SHG) of circumferential guided wave (CGW) propagation in a composite circular tube, and then analyzed the influences of interfacial properties on the SHG effect of primary CGW. Here the effect of SHG of primary CGW propagation is treated as a second-order perturbation to its linear wave response. Due to the convective nonlinearity and the inherent elastic nonlinearity of material, there are second-order bulk driving forces and surface/interface driving stresses in the interior and at the surface/interface of a composite circular tube, when a primary CGW mode propagates along its circumference. Based on the approach of modal expansion analysis for waveguide excitation, the said second-order driving forces/stresses are regarded as the excitation sources to generate a series of double-frequency CGW modes that constitute the second-harmonic field of the primary CGW propagation. It is found that the modal expansion coefficient of each double-frequency CGW mode is closely related to the interfacial stiffness constants that are used to describe the interfacial properties between the inner and outer circular parts of the composite tube. Furthermore, changes in the interfacial stiffness constants essentially influence the dispersion relation of CGW propagation. This will remarkably affect the efficiency of cumulative SHG of primary CGW propagation. Some finite element simulations have been implemented of response characteristics of cumulative SHG to the interfacial properties. Both the theoretical analyses and numerical simulations indicate that the effect of cumulative SHG is found to be much more sensitive to changes in the interfacial properties than primary CGW propagation. The potential of using the effect of cumulative SHG by primary CGW propagation to characterize a minor change in the interfacial properties is considered.

  18. Tube structural integrity evaluation of Palo Verde Unit 1 steam generators for axial upper-bundle cracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodman, B.W.; Begley, J.A.; Brown, S.D.

    1995-12-01

    The analysis of the issue of upper bundle axial ODSCC as it apples to steam generator tube structural integrity in Unit 1 at the Palo Verde Nuclear generating Station is presented in this study. Based on past inspection results for Units 2 and 3 at Palo Verde, the detection of secondary side stress corrosion cracks in the upper bundle region of Unit 1 may occur at some future date. The following discussion provides a description and analysis of the probability of axial ODSCC in Unit 1 leading to the exceedance of Regulatory Guide 1.121 structural limits. The probabilities of structuralmore » limit exceedance are estimated as function of run time using a conservative approach. The chosen approach models the historical development of cracks, crack growth, detection of cracks and subsequent removal from service and the initiation and growth of new cracks during a given cycle of operation. Past performance of all Palo Verde Units as well as the historical performance of other steam generators was considered in the development of cracking statistics for application to Unit 1. Data in the literature and Unit 2 pulled tube examination results were used to construct probability of detection curves for the detection of axial IGSCC/IGA using an MRPC (multi-frequency rotating panake coil) eddy current probe. Crack growth rates were estimated from Unit 2 eddy current inspection data combined with pulled tube examination results and data in the literature. A Monte-Carlo probabilistic model is developed to provide an overall assessment of the risk of Regulatory Guide exceedance during plant operation.« less

  19. Efficacy of an opposite position aspiration on resolution of pneumothorax following CT-guided lung biopsy

    PubMed Central

    Zeng, L-C; Du, Y; Yang, H-F; Xie, M-G; Liao, H-Q; Zhang, Y-D; Li, L; Wang, Q; Hu, L

    2015-01-01

    Objective: To evaluate the efficacy of aspiration in an opposite position to deal with pneumothorax after CT-guided lung biopsy. Methods: A retrospective study was developed involving 210 patients with pneumothorax who had undergone CT-guided percutaneous core biopsies from January 2012 to March 2014 for various pulmonary lesions. Asymptomatic patients with minimal pneumothorax were treated conservatively. Simple manual aspiration was performed for symptomatic patients with minimal pneumothorax and for all patients with moderate to large pneumothorax. An opposite position aspiration was performed when simple manual aspiration failed. The efficacy of simple manual aspiration and the opposite position aspiration was observed. Results: Among 210 patients with pneumothorax, 128 (61.0%) asymptomatic patients with minimal pneumothorax were treated conservatively. The remaining 82 were treated with attempted simple manual aspiration. Out of these 82 patients, simple manual aspiration was successful in 58 (70.7%, 58/82) cases. The complete and partial regression rates were 17.2% (10/58) and 82.8% (48/58), respectively. In the other 24 patients (29.3%, 24/82), simple aspiration technique was ineffective. An opposite position (from prone to supine or vice versa) was applied, and a new biopsy puncture site was chosen for reaspiration. This procedure was successful in 22 patients but not in 2 patients who had to have a chest tube insertion. The complete and partial regression rates were 25.0% (6/24) and 66.7% (16/24), respectively. Applying the new method, the total effective rate of aspiration improved significantly from 70.7% (58/82) to 97.6% (80/82). Conclusion: The opposite position aspiration can be safe, effective and minimally invasive treatment for CT-guided lung biopsy-induced pneumothorax thus reducing the use of chest tube significantly. Advances in knowledge: (1) Opposite position aspiration can elevate the success rate of aspiration significantly (from 70.7% to 97.6% in our study); (2) this procedure is a safe, effective and minimally invasive treatment for pneumothorax caused by biopsy; and (3) opposite position aspiration is a useful technique to reduce the use of chest tube, which has clinical significance. PMID:25966292

  20. Trade Electricity. Lighting--Level 2. Standardized Curriculum.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Office of Occupational and Career Education.

    This curriculum guide consists of nine modules on lighting, one of the three divisions of the standardized trade electricity curriculum in high schools in New York City. The nine modules cover the following subjects: armored cable, rigid conduit, electrical metallic tubing, services and meters, fluorescent lighting, metal molding, wiremold, Romex,…

  1. Mechanics of the Adhesive Properties of Ivy Nanoparticles

    DTIC Science & Technology

    2013-11-21

    macromolecule with multiple physiological functions in the growth of plants, such as signaling, cell wall plasticizer, guiding pollen tube growth, and many...others. The AGPs on the stigma surface were believed to act as an adhesive base for pollens , indicating the adhesion function that AGPs play in plants

  2. Guide to Commensal Rodent Control

    DTIC Science & Technology

    1991-12-01

    in many detergents also fluoresce. For positive identification, place the suspect material on Urease Siom lhymol Blue test paper, moisten with water...are applied in a thin layer in protected rat and mouse r’unways, baitboxes, or tubes along walls. The powder is picked up by the rodents on their feet

  3. Fecal Coliform Determinations. Training Module 5.115.3.77.

    ERIC Educational Resources Information Center

    Kirkwood Community Coll., Cedar Rapids, IA.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with multiple tube and membrane filter techniques for determining fecal coliform concentrations in a wastewater sample. Included are objectives, instructor guides, student handouts and transparency masters. This module considers proper…

  4. Total Coliform Determinations. Training Module 5.205.3.77.

    ERIC Educational Resources Information Center

    Kirkwood Community Coll., Cedar Rapids, IA.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with multiple tube and membrane filter techniques for determining total coliform concentration of a water supply. Included are objectives, instructor guides, student handouts and transparency masters. This module considers proper…

  5. The Cheapbook: A Compendium of Inexpensive Exhibit Ideas, 1995 Edition.

    ERIC Educational Resources Information Center

    Orselli, Paul, Ed.

    This guide includes complete installation descriptions of 30 exhibits. They include: the adjustable birthday cake, ball-in-tube, Bernoulli Box, chain wave, collapsible truss bridge, double wave device, eddy currents raceway, full-length mirror, geodesic domes, giant magnetic tangrams, harmonic cantilever, hyperboloid of revolution, lifting lever,…

  6. Innovative Technique for the Placement of the Drainage Tube for Microendoscopic Spinal Decompression.

    PubMed

    Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2017-02-01

    A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.

  7. Panel 2: Anatomy (Eustachian Tube, Middle Ear, and Mastoid-Anatomy, Physiology, Pathophysiology, and Pathogenesis).

    PubMed

    Alper, Cuneyt M; Luntz, Michal; Takahashi, Haruo; Ghadiali, Samir N; Swarts, J Douglas; Teixeira, Miriam S; Csákányi, Zsuzsanna; Yehudai, Noam; Kania, Romain; Poe, Dennis S

    2017-04-01

    Objective In this report, we review the recent literature (ie, past 4 years) to identify advances in our understanding of the middle ear-mastoid-eustachian tube system. We use this review to determine whether the short-term goals elaborated in the last report were achieved, and we propose updated goals to guide future otitis media research. Data Sources PubMed, Web of Science, Medline. Review Methods The panel topic was subdivided, and each contributor performed a literature search within the given time frame. The keywords searched included middle ear, eustachian tube, and mastoid for their intersection with anatomy, physiology, pathophysiology, and pathology. Preliminary reports from each panel member were consolidated and discussed when the panel met on June 11, 2015. At that meeting, the progress was evaluated and new short-term goals proposed. Conclusions Progress was made on 13 of the 20 short-term goals proposed in 2011. Significant advances were made in the characterization of middle ear gas exchange pathways, modeling eustachian tube function, and preliminary testing of treatments for eustachian tube dysfunction. Implications for Practice In the future, imaging technologies should be developed to noninvasively assess middle ear/eustachian tube structure and physiology with respect to their role in otitis media pathogenesis. The new data derived from these structure/function experiments should be integrated into computational models that can then be used to develop specific hypotheses concerning otitis media pathogenesis and persistence. Finally, rigorous studies on medical or surgical treatments for eustachian tube dysfunction should be undertaken.

  8. Design with constructal theory: Steam generators, turbines and heat exchangers

    NASA Astrophysics Data System (ADS)

    Kim, Yong Sung

    This dissertation shows that the architecture of steam generators, steam turbines and heat exchangers for power plants can be predicted on the basis of the constructal law. According to constructal theory, the flow architecture emerges such that it provides progressively greater access to its currents. Each chapter shows how constructal theory guides the generation of designs in pursuit of higher performance. Chapter two shows the tube diameters, the number of riser tubes, the water circulation rate and the rate of steam production are determined by maximizing the heat transfer rate from hot gases to riser tubes and minimizing the global flow resistance under the fixed volume constraint. Chapter three shows how the optimal spacing between adjacent tubes, the number of tubes for the downcomer and the riser and the location of the flow reversal for the continuous steam generator are determined by the intersection of asymptotes method, and by minimizing the flow resistance under the fixed volume constraints. Chapter four shows that the mass inventory for steam turbines can be distributed between high pressure and low pressure turbines such that the global performance of the power plant is maximal under the total mass constraint. Chapter five presents the more general configuration of a two-stream heat exchanger with forced convection of the hot side and natural circulation on the cold side. Chapter six demonstrates that segmenting a tube with condensation on the outer surface leads to a smaller thermal resistance, and generates design criteria for the performance of multi-tube designs.

  9. Tubing-Electrospinning: A One-Step Process for Fabricating Fibrous Matrices with Spatial, Chemical, and Mechanical Gradients.

    PubMed

    Kim, Jung-Suk; Im, Byung Gee; Jin, Gyuhyung; Jang, Jae-Hyung

    2016-08-31

    Guiding newly generated tissues in a gradient pattern, thereby precisely mimicking inherent tissue morphology and subsequently arranging the intimate networks between adjacent tissues, is essential to raise the technical levels of tissue engineering and facilitate its transition into the clinic. In this study, a straightforward electrospinning method (the tubing-electrospinning technique) was developed to create fibrous matrices readily with diverse gradient patterns and to induce patterned cellular responses. Gradient fibrous matrices can be produced simply by installing a series of polymer-containing lengths of tubing into an electrospinning circuit and sequentially processing polymers without a time lag. The loading of polymer samples with different characteristics, including concentration, wettability, and mechanical properties, into the tubing system enabled unique features in fibrous matrices, such as longitudinal gradients in fiber density, surface properties, and mechanical stiffness. The resulting fibrous gradients were shown to arrange cellular migration and residence in a gradient manner, thereby offering efficient cues to mediate patterned tissue formation. The one-step process using tubing-electrospinning apparatus can be used without significant modifications regardless of the type of fibrous gradient. Hence, the tubing-electrospinning system can serve as a platform that can be readily used by a wide-range of users to induce patterned tissue formation in a gradient manner, which will ultimately improve the functionality of tissue engineering scaffolds.

  10. Literature review on risky driving videos on YouTube: Unknown effects and areas for concern?

    PubMed

    Vingilis, Evelyn; Yıldırım-Yenier, Zümrüt; Vingilis-Jaremko, Larissa; Wickens, Christine; Seeley, Jane; Fleiter, Judy; Grushka, Daniel H

    2017-08-18

    Entry of terms reflective of extreme risky driving behaviors into the YouTube website yields millions of videos. The majority of the top 20 highly subscribed automotive YouTube websites are focused on high-performance vehicles, high speed, and often risky driving. Moreover, young men are the heaviest users of online video sharing sites, overall streaming more videos, and watching them longer than any other group. The purpose of this article is to review the literature on YouTube videos and risky driving. A systematic search was performed using the following specialized database sources-Scopus, PubMed, Web of Science, ERIC, and Google Scholar-for the years 2005-2015 for articles in the English language. Search words included "YouTube AND driving," "YouTube AND speeding," "YouTube AND racing." No published research was found on the content of risky driving videos or on the effects of these videos on viewers. This literature review presents the current state of our published knowledge on the topic, which includes a review of the effects of mass media on risky driving cognitions; attitudes and behavior; similarities and differences between mass and social media; information on the YouTube platform; psychological theories that could support YouTube's potential effects on driving behavior; and 2 examples of risky driving behaviors ("sidewalk skiing" and "ghost riding the whip") suggestive of varying levels of modeling behavior in subsequent YouTube videos. Every month about 1 billion individuals are reported to view YouTube videos (ebizMBA Guide 2015 ) and young men are the heaviest users, overall streaming more YouTube videos and watching them longer than women and other age groups (Nielsen 2011 ). This group is also the most dangerous group in traffic, engaging in more per capita violations and experiencing more per capita injuries and fatalities (e.g., Parker et al. 1995 ; Reason et al. 1990 ; Transport Canada 2015 ; World Health Organization 2015 ). YouTube also contains many channels depicting risky driving videos. The time has come for the traffic safety community to begin exploring these relationships.

  11. Interactive-rate Motion Planning for Concentric Tube Robots.

    PubMed

    Torres, Luis G; Baykal, Cenk; Alterovitz, Ron

    2014-05-01

    Concentric tube robots may enable new, safer minimally invasive surgical procedures by moving along curved paths to reach difficult-to-reach sites in a patient's anatomy. Operating these devices is challenging due to their complex, unintuitive kinematics and the need to avoid sensitive structures in the anatomy. In this paper, we present a motion planning method that computes collision-free motion plans for concentric tube robots at interactive rates. Our method's high speed enables a user to continuously and freely move the robot's tip while the motion planner ensures that the robot's shaft does not collide with any anatomical obstacles. Our approach uses a highly accurate mechanical model of tube interactions, which is important since small movements of the tip position may require large changes in the shape of the device's shaft. Our motion planner achieves its high speed and accuracy by combining offline precomputation of a collision-free roadmap with online position control. We demonstrate our interactive planner in a simulated neurosurgical scenario where a user guides the robot's tip through the environment while the robot automatically avoids collisions with the anatomical obstacles.

  12. PNNL Tests Fish Passage System

    ScienceCinema

    Colotelo, Alison

    2018-01-16

    Scientists from PNNL are testing a fish transportation system developed by Whooshh Innovations. The Whooshh system uses a flexible tube that works a bit like a vacuum, guiding fish over hydroelectric dams or other structures. Compared to methods used today, this system could save money while granting fish quicker, safer passage through dams and hatcheries.

  13. 75 FR 54048 - Energy Efficiency Program: Test Procedure for Televisions; Request for Information and Request...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-03

    ... plasma, cathode ray tube (CRT), and locally dimmed LED-backlit LCD designs. As a result, it can be useful.... This may disadvantage Plasma TVs, and has proven to be unpredictable with LED models. Furthermore, the... by the electronic programming guide, monitoring for emergency messaging/ communications and/or...

  14. Sidewall penetrator for oil wells

    NASA Technical Reports Server (NTRS)

    Collins, E. R., Jr.

    1981-01-01

    Penetrator bores horizontal holes in well casing to increase trapped oil drainage. Several penetrators operated by common drive are inserted into well at once. Shaft, made from spiraling cable, rotates and thrusts simultaneously through rigid curvilinear guide tube forcing bit through casing into strata. Device pierces more deeply than armor-piercing bullets and shaped explosive charges.

  15. PNNL Tests Fish Passage System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colotelo, Alison

    2015-03-13

    Scientists from PNNL are testing a fish transportation system developed by Whooshh Innovations. The Whooshh system uses a flexible tube that works a bit like a vacuum, guiding fish over hydroelectric dams or other structures. Compared to methods used today, this system could save money while granting fish quicker, safer passage through dams and hatcheries.

  16. High-Velocity Impact Fragmentation of Projectiles Experimental Results

    DTIC Science & Technology

    2016-10-01

    Program (JIMTP) Tube -Launched, Optically Tracked, Wire-Guided (TOW) 2B Insensitive Munitions (IM) Warhead effort. The referenced experiments were...conducted to determine the velocity reduction and fragmentation profile of barrier materials subjected to impact by the IM Fragment Impact (FI) test...9 LIST OF TABLES Table Title Page 1. Single Material Test Matrix

  17. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Apparatus and devices under Category IV(c). 121... UNITED STATES MUNITIONS LIST Enumeration of Articles § 121.5 Apparatus and devices under Category IV(c... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and...

  18. Application of semi-automated ultrasonography on nutritional support for severe acute pancreatitis.

    PubMed

    Li, Ying; Ye, Yu; Yang, Mei; Ruan, Haiying; Yu, Yuan

    2018-04-25

    To evaluate the application value of semi-automated ultrasound on the guidance of nasogastrojejunal tube replacement for patients with acute severe pancreatitis (ASP), as well as the value of the nutritional support for standardized treatment in clinical practice. The retrospective research was performed in our hospital, and 34 patients suffering from ASP were enrolled into this study. All these identified participants ever received CT scans in order to make definitive diagnoses. Following, these patients received semi-automated ultrasound examinations within 1 days after their onset, in order to provide enteral nutrititon treatment via nasogastrojejunal tube, or freehand nasogastrojejunal tube replacement. In terms of statistical analysis, the application value of semi-automated ultrasound guidance on nasogastrojejunal tube replacement was evaluated, and was compared with tube replacement of no guidance. After cathetering, the additional enteral nutrition was provided, and its therapeutic effect on SAP was analyzed in further. A total of 34 patients with pancreatitis were identified in this research, 29 cases with necrosis of pancreas parenchyma. After further examinations, 32 cases were SAP, 2 cases were mild acute pancreatitis. When the firm diagnosis was made, additional enteral nutrition (EN) was given, all the patient conditions appeared good, and they all were satisfied with this kind of nutritional support. According to our clinical experience, when there was 200-250 ml liquid in the stomach, the successful rate of intubation appeared higher. Additionally, the comparison between ultrasound-guided and freehand nasogastrojejunal tube replacement was made. According to the statistical results, in terms of the utilization ratio of nutritional support, it was better in ultrasound-guided group, when compared with it in freehand group, within 1 day, after 3 days and after 7 days (7/20 versus 2/14; P < 0.05; 14/20 versus 6/14; P < 0.05; 20/20 versus 12/14; P < 0.05). Besides, the complications caused by cathetering between two groups was not statistically different (P > 0.05). It can be indicated that semi-automated ultrasound guidance is a reliable method for nasogastrojejunal tube replacement, and should be substituted for no guidance of cathetering. In terms of therapeutic effect of EN, additional nutritional support contributed to significantly improve the prognosis of SAP patients, and should be widely recommended in clinical practice. Surely, this conclusion should be evaluated in further, by means of randomized controlled trials and economic evaluation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Visualizing lava flow interiors with LiDAR

    NASA Astrophysics Data System (ADS)

    Whelley, P.; Garry, W. B.; Young, K.; Kruse, S.; Esmaeili, S.; Bell, E.; Paylor, R.

    2017-12-01

    Lava tube caves provide unprecedented access to the shallow (meters to tens of meters) interiors of lava flows. Surveying tube geometry and morphology can illuminate lava flow thermal history and emplacement mechanics. In an expedition to Lava Beds National Monument, California, our team collected ultra-high-resolution (< 10 cm) topography from the interiors of four lava tubes using a terrestrial laser scanner (TLS). More than 78 GB of point data (latitude, longitude, elevation) of the surface and interiors of Hercules Leg, Skull, Valentine and, Indian Well Caves were collected. For example, our point cloud for 50 m of Valentine Cave contains 748 million points (interior: 478 million, exterior: 270 million) from 28 TLS scans. The tubes visited range in diameter from < 1 m to > 10 m, and from 1 m to < 20 m of overburden. The interior morphology of the tubes remain pristine (i.e., un-eroded) after more than 10,000 years. The TLS data illuminate fresh-looking lava tube flow features (e.g., lava-coils, pillars, benches, and ropes) and post-emplacement deformation features (e.g., fractures, lava-drips, molded ceilings, and drop-blocks). Furthermore, the data provide context for geochemical and geophysical observations made in conjunction with the TLS survey. Lava tube morphology, observable in the TLS data, informs each tube's emplacement history. Skull cave is the largest ( 20 m in diameter) requiring a comparatively high lava discharge rate and suggesting this cave formed by roofing over a lava channel. In contrast, Valentine, Hercules Leg, and Indian Well Caves are narrower, (1 to 4 m) and have many branches, some of which rejoin the "main passage", suggesting they formed by developing a network of pathways within the lava flow. We will showcase video fly-throughs for these lava tubes, plus manipulable point clouds. The interactive eLighning presentation will encourage hands-on exploration of these unique data. We will guide them on a tour of the underground to discover and compare different morphologies of lava tubes.

  20. Thrust Augmentation Measurements Using a Pulse Detonation Engine Ejector

    NASA Technical Reports Server (NTRS)

    Santoro, Robert J.; Pal, Sibtosh

    2003-01-01

    The present NASA GRC-funded three-year research project is focused on studying PDE driven ejectors applicable to a hybrid Pulse Detonation/Turbofan Engine. The objective of the study is to characterize the PDE-ejector thrust augmentation. A PDE-ejector system has been designed to provide critical experimental data for assessing the performance enhancements possible with this technology. Completed tasks include demonstration of a thrust stand for measuring average thrust for detonation tube multi-cycle operation, and design of a 72-in.-long, 2.25-in.-diameter (ID) detonation tube and modular ejector assembly. This assembly will allow testing of both straight and contoured ejector geometries. Initial ejectors that have been fabricated are 72-in.-long-constant-diameter tubes (4-, 5-, and 6-in.-diameter) instrumented with high-frequency pressure transducers. The assembly has been designed such that the detonation tube exit can be positioned at various locations within the ejector tube. PDE-ejector system experiments with gaseous ethylene/ nitrogen/oxygen propellants will commence in the very near future. The program benefits from collaborations with Prof. Merkle of University of Tennessee whose PDE-ejector analysis helps guide the experiments. The present research effort will increase the TRL of PDE-ejectors from its current level of 2 to a level of 3.

  1. The NASA, Marshall Space Flight Center drop tube user's manual

    NASA Technical Reports Server (NTRS)

    Rathz, Thomas J.; Robinson, Michael B.

    1990-01-01

    A comprehensive description of the structural and instrumentation hardware and the experimental capabilities of the 105-meter Marshall Space Flight Center Drop Tube Facility is given. This document is to serve as a guide to the investigator who wishes to perform materials processing experiments in the Drop Tube. Particular attention is given to the Tube's hardware to which an investigator must interface to perform experiments. This hardware consists of the permanent structural hardware (with such items as vacuum flanges), and the experimental hardware (with the furnaces and the sample insertion devices). Two furnaces, an electron-beam and an electromagnetic levitator, are currently used to melt metallic samples in a process environment that can range from 10(exp -6) Torr to 1 atmosphere. Details of these furnaces, the processing environment gases/vacuum, the electrical power, and data acquisition capabilities are specified to allow an investigator to design his/her experiment to maximize successful results and to reduce experimental setup time on the Tube. Various devices used to catch samples while inflicting minimum damage and to enhance turnaround time between experiments are described. Enough information is provided to allow an investigator who wishes to build his/her own furnace or sample catch devices to easily interface it to the Tube. The experimental instrumentation and data acquisition systems used to perform pre-drop and in-flight measurements of the melting and solidification process are also detailed. Typical experimental results are presented as an indicator of the type of data that is provided by the Drop Tube Facility. A summary bibliography of past Drop Tube experiments is provided, and an appendix explaining the noncontact temperature determination of free-falling drops is provided. This document is to be revised occasionally as improvements to the Facility are made and as the summary bibliography grows.

  2. Magnetic Shocks and Substructures Excited by Torsional Alfvén Wave Interactions in Merging Expanding Flux Tubes

    NASA Astrophysics Data System (ADS)

    Snow, B.; Fedun, V.; Gent, F. A.; Verth, G.; Erdélyi, R.

    2018-04-01

    Vortex motions are frequently observed on the solar photosphere. These motions may play a key role in the transport of energy and momentum from the lower atmosphere into the upper solar atmosphere, contributing to coronal heating. The lower solar atmosphere also consists of complex networks of flux tubes that expand and merge throughout the chromosphere and upper atmosphere. We perform numerical simulations to investigate the behavior of vortex-driven waves propagating in a pair of such flux tubes in a non-force-free equilibrium with a realistically modeled solar atmosphere. The two flux tubes are independently perturbed at their footpoints by counter-rotating vortex motions. When the flux tubes merge, the vortex motions interact both linearly and nonlinearly. The linear interactions generate many small-scale transient magnetic substructures due to the magnetic stress imposed by the vortex motions. Thus, an initially monolithic tube is separated into a complex multithreaded tube due to the photospheric vortex motions. The wave interactions also drive a superposition that increases in amplitude until it exceeds the local Mach number and produces shocks that propagate upward with speeds of approximately 50 km s‑1. The shocks act as conduits transporting momentum and energy upward, and heating the local plasma by more than an order of magnitude, with a peak temperature of approximately 60,000 K. Therefore, we present a new mechanism for the generation of magnetic waveguides from the lower solar atmosphere to the solar corona. This wave guide appears as the result of interacting perturbations in neighboring flux tubes. Thus, the interactions of photospheric vortex motions is a potentially significant mechanism for energy transfer from the lower to upper solar atmosphere.

  3. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.

    PubMed

    Porcel, José M

    2018-04-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  4. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

    PubMed Central

    2018-01-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity (“water seal”) drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. PMID:29372629

  5. Runaway transient simulation of a model Kaplan turbine

    NASA Astrophysics Data System (ADS)

    Liu, S.; Zhou, D.; Liu, D.; Wu, Y.; Nishi, M.

    2010-08-01

    The runaway transient is a typical transient process of a hydro power unit, where the rotational speed of a turbine runner rapidly increases up to the runaway speed under a working head as the guide vanes cannot be closed due to some reason at the load rejection. In the present paper, the characteristics of the runaway transient of a model Kaplan turbine having ns = 479(m-kW) is simulated by using a time-dependent CFD technique where equation of rotational motion of runner, continuity equation and unsteady RANS equations with RNG k-epsilon turbulence model are solved iteratively. In the calculation, unstructured mesh is used to the whole flow passage, which consists of several sub-domains: entrance, casing, stay vanes + guide vanes, guide section, runner and draft tube. And variable speed sliding mesh technique is used to exchange interface flow information between moving part and stationary part, and three-dimensional unstructured dynamic mesh technique is also adopted to ensure mesh quality. Two cases were treated in the simulation of runaway transient characteristics after load rejection: one is the rated operating condition as the initial condition, and the other is the condition at the maximum head. Regarding the runaway speed, the experimental speed is 1.45 times the initial speed and the calculation is 1.47 times the initial for the former case. In the latter case, the experiment and the calculation are 1.67 times and 1.69 times respectively. From these results, it is recognized that satisfactorily prediction will be possible by using the present numerical method. Further, numerical results show that the swirl in the draft-tube flow becomes stronger in the latter part of the transient process so that a vortex rope will occur in the draft tube and its precession will cause the pressure fluctuations which sometimes affect the stability of hydro power system considerably.

  6. Cyclic fatigue testing of nickel-titanium endodontic instruments.

    PubMed

    Pruett, J P; Clement, D J; Carnes, D L

    1997-02-01

    Cyclic fatigue of nickel-titanium, engine-driven instruments was studied by determining the effect of canal curvature and operating speed on the breakage of Lightspeed instruments. A new method of canal curvature evaluation that addressed both angle and abruptness of curvature was introduced. Canal curvature was simulated by constructing six curved stainless-steel guide tubes with angles of curvature of 30, 45, or 60 degrees, and radii of curvature of 2 or 5 mm. Size #30 and #40 Light-speed instruments were placed through the guide tubes and the heads secured in the collet of a Mangtrol Dynamometer. A simulated operating load of 10 g-cm was applied. Instruments were able to rotate freely in the test apparatus at speeds of 750, 1300, or 2000 rpm until separation occurred. Cycles to failure were determined. Cycles to failure were not affected by rpm. Instruments did not separate at the head, but rather at the point of maximum flexure of the shaft, corresponding to the midpoint of curvature within the guide tube. The instruments with larger diameter shafts, #40, failed after significantly fewer cycles than did #30 instruments under identical test conditions. Multivariable analysis of variance indicated that cycles to failure significantly decreased as the radius of curvature decreased from 5 mm to 2 mm and as the angle of curvature increased greater than 30 degrees (p < 0.05, power = 0.9). Scanning electron microscopic evaluation revealed ductile fracture as the fatigue failure mode. These results indicate that, for nickel-titanium, engine-driven rotary instruments, the radius of curvature, angle of curvature, and instrument size are more important than operating speed for predicting separation. This study supports engineering concepts of cyclic fatigue failure and suggests that standardized fatigue tests of nickel-titanium rotary instruments should include dynamic operation in a flexed state. The results also suggest that the effect of the radius of curvature as an independent variable should be considered when evaluating studies of root canal instrumentation.

  7. Evaluation of biodegradable electric conductive tube-guides and mesenchymal stem cells

    PubMed Central

    Ribeiro, Jorge; Pereira, Tiago; Caseiro, Ana Rita; Armada-da-Silva, Paulo; Pires, Isabel; Prada, Justina; Amorim, Irina; Amado, Sandra; França, Miguel; Gonçalves, Carolina; Lopes, Maria Ascensão; Santos, José Domingos; Silva, Dina Morais; Geuna, Stefano; Luís, Ana Lúcia; Maurício, Ana Colette

    2015-01-01

    AIM: To study the therapeutic effect of three tube-guides with electrical conductivity associated to mesenchymal stem cells (MSCs) on neuro-muscular regeneration after neurotmesis. METHODS: Rats with 10-mm gap nerve injury were tested using polyvinyl alcohol (PVA), PVA-carbon nanotubes (CNTs) and MSCs, and PVA-polypyrrole (PPy). The regenerated nerves and tibialis anterior muscles were processed for stereological studies after 20 wk. The functional recovery was assessed serially for gait biomechanical analysis, by extensor postural thrust, sciatic functional index and static sciatic functional index (SSI), and by withdrawal reflex latency (WRL). In vitro studies included cytocompatibility, flow cytometry, reverse transcriptase polymerase chain reaction and karyotype analysis of the MSCs. Histopathology of lung, liver, kidneys, and regional lymph nodes ensured the biomaterials biocompatibility. RESULTS: SSI remained negative throughout and independently from treatment. Differences between treted groups in the severity of changes in WRL existed, showing a faster regeneration for PVA-CNTs-MSCs (P < 0.05). At toe-off, less acute ankle joint angles were seen for PVA-CNTs-MSCs group (P = 0.051) suggesting improved ankle muscles function during the push off phase of the gait cycle. In PVA-PPy and PVA-CNTs groups, there was a 25% and 42% increase of average fiber area and a 13% and 21% increase of the “minimal Feret’s diameter” respectively. Stereological analysis disclosed a significantly (P < 0.05) increased myelin thickness (M), ratio myelin thickness/axon diameter (M/d) and ratio axon diameter/fiber diameter (d/D; g-ratio) in PVA-CNT-MSCs group (P < 0.05). CONCLUSION: Results revealed that treatment with MSCs and PVA-CNTs tube-guides induced better nerve fiber regeneration. Functional and kinematics analysis revealed positive synergistic effects brought by MSCs and PVA-CNTs. The PVA-CNTs and PVA-PPy are promising scaffolds with electric conductive properties, bio- and cytocompatible that might prevent the secondary neurogenic muscular atrophy by improving the reestablishment of the neuro-muscular junction. PMID:26240682

  8. Visually guided tube thoracostomy insertion comparison to standard of care in a large animal model.

    PubMed

    Hernandez, Matthew C; Vogelsang, David; Anderson, Jeff R; Thiels, Cornelius A; Beilman, Gregory; Zielinski, Martin D; Aho, Johnathon M

    2017-04-01

    Tube thoracostomy (TT) is a lifesaving procedure for a variety of thoracic pathologies. The most commonly utilized method for placement involves open dissection and blind insertion. Image guided placement is commonly utilized but is limited by an inability to see distal placement location. Unfortunately, TT is not without complications. We aim to demonstrate the feasibility of a disposable device to allow for visually directed TT placement compared to the standard of care in a large animal model. Three swine were sequentially orotracheally intubated and anesthetized. TT was conducted utilizing a novel visualization device, tube thoracostomy visual trocar (TTVT) and standard of care (open technique). Position of the TT in the chest cavity were recorded using direct thoracoscopic inspection and radiographic imaging with the operator blinded to results. Complications were evaluated using a validated complication grading system. Standard descriptive statistical analyses were performed. Thirty TT were placed, 15 using TTVT technique, 15 using standard of care open technique. All of the TT placed using TTVT were without complication and in optimal position. Conversely, 27% of TT placed using standard of care open technique resulted in complications. Necropsy revealed no injury to intrathoracic organs. Visual directed TT placement using TTVT is feasible and non-inferior to the standard of care in a large animal model. This improvement in instrumentation has the potential to greatly improve the safety of TT. Further study in humans is required. Therapeutic Level II. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Gamma and fast neutron radiation monitoring inside spent reactor fuel assemblies

    NASA Astrophysics Data System (ADS)

    Lakosi, L.; Tam Nguyen, C.

    2007-09-01

    Gamma and neutron signatures of spent reactor fuel were monitored by small-size silicon diode and track etch detectors, respectively, in a nuclear power plant (NPP). These signatures, reflecting gross gamma intensity and the 242,244Cm content, contain information on the burn-up (BU) and cooling time (CT) of the fuel. The small size of the detectors allows close access to inside parts of the assemblies out of reach of other methods. A commercial Si diode was encapsulated in a cylindrical steel case and was used for gross γ monitoring. CR-39 detectors were used for neutron measurements. Irradiation exposures at the NPP were implemented in the central dosimetric channel of spent fuel assemblies (SFAs) stored in borated water. Gross γ and neutron axial profiles were taken up by scanning with the aid of a long steel guide tube, lowered down to the spent fuel pond by crane and fitted to the headpiece of the fuel assemblies. Gamma measurements were performed using a long cable introduced in this tube, with the Si diode at the end. A long steel wire was also led through the guide tube, to which a chain of 15 sample holder capsules was attached, each containing a track detector. Gamma dose rates of 0.1-10 kGy h -1, while neutron fluxes in a range of (0.25-26) 10 4 cm -2 s -1 were recorded. The results are in good correlation with those of a calculation for spent fuel neutron yield.

  10. Jejunal feeding tubes can be efficiently and independently placed by intensive care unit teams.

    PubMed

    Welpe, Pascal; Frutiger, Adrian; Vanek, Patrik; Kleger, Gian-Reto

    2010-01-01

    Nutrition support is an important therapeutic measure in critically ill patients. Several studies have shown that the enteral route is preferable to the parenteral route. Insertion of a feeding tube beyond the ligament of Treitz combined with continuous gastric drainage will reduce regurgitation and probably also the rate of nosocomial pneumonia. This study was conducted to assess the safety, success rate, and time required to establish jejunal nutrition by the fluoroscopy-guided technique in intensive care unit (ICU) patients. This was a prospective observational study in the ICUs of a 300-bed and a 600-bed community hospital. Indications were large gastric residuals during attempted gastric feeding, severe acute pancreatitis, or recurrent aspiration. Feeding tubes were introduced by the ICU staff at bedside under fluoroscopic guidance (a senior ICU physician and a resident or a registered ICU nurse). The correct jejunal position was documented by the application of a radiopaque contrast medium through the tube. After confirmation of the correct position, jejunal tube feeding was immediately started. The insertion procedure in 38 patients lasted a median of 17 minutes. The median time from decision to place the tube until start of enteral feeding was 141 minutes. The success rate was 84.2%. No adverse events were observed. Fluoroscopic placement of a jejunal feeding tube at the bedside is fast, is safe, and has a high success rate when performed by well-trained ICU staff. Using this method makes the ICU team more self-sufficient when critically ill patients require enteral nutrition and no gastroenterologist is available.

  11. Analysis on influence of guide vanes closure laws of pump-turbine on load rejection transient process

    NASA Astrophysics Data System (ADS)

    Yao, Z.; Bi, H. L.; Huang, Q. S.; Li, Z. J.; Wang, Z. W.

    2013-12-01

    In load rejection transient process, the sudden shut down of guide vanes may cause units speed rise and a sharp increase in water hammer pressure of diversion system, which endangers the safety operation of the power plant. Adopting reasonable guide vane closure law is a kind of economic and effective measurement to reduce the water hammer pressure and limit rotational speed increases. In this paper, combined with Guangzhou Pumped Storage Power Station plant A, the load rejection condition under different guide vanes closure laws is calculated and the key factor of guide vanes closure laws on the impact of the load rejection transition process is analyzed. The different inflection points, which are the closure modes, on the impact of unit speed change, water level fluctuation of surge tank, and the pressure fluctuation of volute inlet and draft tube inlet are further discussed. By compared with the calculation results, a reasonable guide vanes inflection point position can be determined according to security requirements and a reasonable guide vanes closure law can be attained to effectively coordinate the unit speed rise and the rapid pressure change in the load rejection transient process.

  12. Mini gamma camera, camera system and method of use

    DOEpatents

    Majewski, Stanislaw; Weisenberger, Andrew G.; Wojcik, Randolph F.

    2001-01-01

    A gamma camera comprising essentially and in order from the front outer or gamma ray impinging surface: 1) a collimator, 2) a scintillator layer, 3) a light guide, 4) an array of position sensitive, high resolution photomultiplier tubes, and 5) printed circuitry for receipt of the output of the photomultipliers. There is also described, a system wherein the output supplied by the high resolution, position sensitive photomultipiler tubes is communicated to: a) a digitizer and b) a computer where it is processed using advanced image processing techniques and a specific algorithm to calculate the center of gravity of any abnormality observed during imaging, and c) optional image display and telecommunications ports.

  13. Numerical Investigation for Strengthening Heat Transfer Mechanism of the Tube-Row Heat Exchanger in a Compact Thermoelectric Generator

    NASA Astrophysics Data System (ADS)

    Zhang, Zheng; Chen, Zijian; Liu, Hongwu; Yue, Hao; Chen, Dongbo; Qin, Delei

    2018-04-01

    According to the basic principle of heat transfer enhancement, a 1-kW compact thermoelectric generator (TEG) is proposed that is suitable for use at high temperatures and high flow speeds. The associated heat exchanger has a tube-row structure with a guide-plate to control the thermal current. The heat exchanger has a volume of 7 L, and the TEG has a mass of 8 kg (excluding the thermoelectric modules (TEMs)). In this paper, the heat transfer process of the tube-row exchanger is modeled and analyzed numerically; and the influences of its structure on the heat transfer and temperature status of the TEMs are investigated. The results show that use of the thin - wall pipes and increase of surface roughness inside the pipes are effective ways to improve the heat transfer efficiency, obtain the rated surface temperature, and make the TEG compact and lightweight. Furthermore, under the same conditions, the calculated results are compared with the data of a fin heat exchanger. The comparison results show that the volume and mass of the tube-row heat exchanger are 19% and 33% lower than those of the fin type unit, and that the pressure drop is reduced by 16%. In addition, the average temperature in the tube-row heat exchanger is increased by 15°C and the average temperature difference is increased by 19°C; the tube-row TEG has a more compact volume and better temperature characteristics.

  14. Future ultra-speed tube-flight

    NASA Astrophysics Data System (ADS)

    Salter, Robert M.

    1994-05-01

    Future long-link, ultra-speed, surface transport systems will require electromagnetically (EM) driven and restrained vehicles operating under reduced-atmosphere in very straight tubes. Such tube-flight trains will be safe, energy conservative, pollution-free, and in a protected environment. Hypersonic (and even hyperballistic) speeds are theoretically achievable. Ultimate system choices will represent tradeoffs between amoritized capital costs (ACC) and operating costs. For example, long coasting links might employ aerodynamic lift coupled with EM restraint and drag make-up. Optimized, combined EM lift, and thrust vectors could reduce energy costs but at increased ACC. (Repulsive levitation can produce lift-over-drag l/d ratios a decade greater than aerodynamic), Alternatively, vehicle-emanated, induced-mirror fields in a conducting (aluminum sheet) road bed could reduce ACC but at substantial energy costs. Ultra-speed tube flight will demand fast-acting, high-precision sensors and computerized magnetic shimming. This same control system can maintain a magnetic 'guide way' invariant in inertial space with inertial detectors imbedded in tube structures to sense and correct for earth tremors. Ultra-speed tube flight can complete with aircraft for transit time and can provide even greater passenger convenience by single-model connections with local subways and feeder lines. Although cargo transport generally will not need to be performed at ultra speeds, such speeds may well be desirable for high throughput to optimize channel costs. Thus, a large and expensive pipeline might be replaced with small EM-driven pallets at high speeds.

  15. Age as a Determinant to Select an Anesthesia Method for Tympanostomy Tube Insertion in a Pediatric Population

    PubMed Central

    Jung, Kihwan; Kim, Hojong

    2015-01-01

    Background and Objectives To evaluate the relationship between age and anesthesia method used for tympanostomy tube insertion (TTI) and to provide evidence to guide the selection of an appropriate anesthesia method in children. Subjects and Methods We performed a retrospective review of children under 15 years of age who underwent tympanostomy tube insertion (n=159) or myringotomy alone (n=175) under local or general anesthesia by a single surgeon at a university-based, secondary care referral hospital. Epidermiologic data between local and general anesthesia groups as well as between TTI and myringotomy were analyzed. Medical costs were compared between local and general anesthesia groups. Results Children who received local anesthesia were significantly older than those who received general anesthesia. Unilateral tympanostomy tube insertion was performed more frequently under local anesthesia than bilateral. Logistic regression modeling showed that local anesthesia was more frequently applied in older children (odds ratio=1.041) and for unilateral tympanostomy tube insertion (odds ratio=8.990). The cut-off value of age for local anesthesia was roughly 5 years. Conclusions In a pediatric population at a single medical center, age and whether unilateral or bilateral procedures were required were important factors in selecting an anesthesia method for tympanostomy tube insertion. Our findings suggest that local anesthesia can be preferentially considered for children 5 years of age or older, especially in those with unilateral otitis media with effusion. PMID:26185791

  16. Numerical Investigation for Strengthening Heat Transfer Mechanism of the Tube-Row Heat Exchanger in a Compact Thermoelectric Generator

    NASA Astrophysics Data System (ADS)

    Zhang, Zheng; Chen, Zijian; Liu, Hongwu; Yue, Hao; Chen, Dongbo; Qin, Delei

    2018-06-01

    According to the basic principle of heat transfer enhancement, a 1-kW compact thermoelectric generator (TEG) is proposed that is suitable for use at high temperatures and high flow speeds. The associated heat exchanger has a tube-row structure with a guide-plate to control the thermal current. The heat exchanger has a volume of 7 L, and the TEG has a mass of 8 kg (excluding the thermoelectric modules (TEMs)). In this paper, the heat transfer process of the tube-row exchanger is modeled and analyzed numerically; and the influences of its structure on the heat transfer and temperature status of the TEMs are investigated. The results show that use of the thin - wall pipes and increase of surface roughness inside the pipes are effective ways to improve the heat transfer efficiency, obtain the rated surface temperature, and make the TEG compact and lightweight. Furthermore, under the same conditions, the calculated results are compared with the data of a fin heat exchanger. The comparison results show that the volume and mass of the tube-row heat exchanger are 19% and 33% lower than those of the fin type unit, and that the pressure drop is reduced by 16%. In addition, the average temperature in the tube-row heat exchanger is increased by 15°C and the average temperature difference is increased by 19°C; the tube-row TEG has a more compact volume and better temperature characteristics.

  17. Future ultra-speed tube-flight

    NASA Technical Reports Server (NTRS)

    Salter, Robert M.

    1994-01-01

    Future long-link, ultra-speed, surface transport systems will require electromagnetically (EM) driven and restrained vehicles operating under reduced-atmosphere in very straight tubes. Such tube-flight trains will be safe, energy conservative, pollution-free, and in a protected environment. Hypersonic (and even hyperballistic) speeds are theoretically achievable. Ultimate system choices will represent tradeoffs between amoritized capital costs (ACC) and operating costs. For example, long coasting links might employ aerodynamic lift coupled with EM restraint and drag make-up. Optimized, combined EM lift, and thrust vectors could reduce energy costs but at increased ACC. (Repulsive levitation can produce lift-over-drag l/d ratios a decade greater than aerodynamic), Alternatively, vehicle-emanated, induced-mirror fields in a conducting (aluminum sheet) road bed could reduce ACC but at substantial energy costs. Ultra-speed tube flight will demand fast-acting, high-precision sensors and computerized magnetic shimming. This same control system can maintain a magnetic 'guide way' invariant in inertial space with inertial detectors imbedded in tube structures to sense and correct for earth tremors. Ultra-speed tube flight can complete with aircraft for transit time and can provide even greater passenger convenience by single-model connections with local subways and feeder lines. Although cargo transport generally will not need to be performed at ultra speeds, such speeds may well be desirable for high throughput to optimize channel costs. Thus, a large and expensive pipeline might be replaced with small EM-driven pallets at high speeds.

  18. Assessing copper pinhole leaks in residential plumbing.

    PubMed

    Edwards, M; Rushing, J C; Kvech, S; Reiber, S

    2004-01-01

    Pinhole leaks in copper tubes are a major problem for homeowners, and an aggressive conscientious effort by utilities is recommended to diagnose the problem and identify potential solutions. In a case study at one utility, pinhole leak frequency data was compiled and a methodology was followed that might prove to be a useful guide for those facing similar problems.

  19. 50 CFR 218.20 - Specified activity and specified geographical area and effective dates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (Hellfire missile); (B) Tube-launched Optically tracked Wire-guided (TOW) missile; (C) Mine Neutralization... NEW charges)—up to 100 exercises over the course of 5 years (an average of 20 per year); (B) Missile Exercise (MISSILEX) (Air-to-Surface; Hellfire missile)—up to 40 exercises over the course of 5 years (an...

  20. 50 CFR 218.20 - Specified activity and specified geographical area and effective dates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Explosives: (A) AGM-114 (Hellfire missile); (B) Tube-launched Optically tracked Wire-guided (TOW) missile; (C...) Missile Exercise (MISSILEX) (Air-to-Surface; Hellfire missile)—up to 40 exercises over the course of 5 years (an average of 8 per year); (C) Missile Exercise (MISSILEX) (Air-to-Surface; TOW)—up to 40...

  1. 50 CFR 218.20 - Specified activity and specified geographical area and effective dates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Explosives: (A) AGM-114 (Hellfire missile); (B) Tube-launched Optically tracked Wire-guided (TOW) missile; (C...) Missile Exercise (MISSILEX) (Air-to-Surface; Hellfire missile)—up to 40 exercises over the course of 5 years (an average of 8 per year); (C) Missile Exercise (MISSILEX) (Air-to-Surface; TOW)—up to 40...

  2. 50 CFR 218.20 - Specified activity and specified geographical area and effective dates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (Hellfire missile); (B) Tube-launched Optically tracked Wire-guided (TOW) missile; (C) Mine Neutralization... NEW charges)—up to 100 exercises over the course of 5 years (an average of 20 per year); (B) Missile Exercise (MISSILEX) (Air-to-Surface; Hellfire missile)—up to 40 exercises over the course of 5 years (an...

  3. Citizen Airman Magazine > Home

    Science.gov Websites

    Past Issues Social Media Twitter Logo Youth aviation event sparks new energy - https://t.co/TJG3nKAs4D ! Just getting things setup! Facebook 76 Like Us Twitter 278 Follow Us YouTube Blog RSS Air Force Social Media Guide (PDF) USAF Social Media Sites About AFRC AFR Mission Briefing Mission Briefing AFR Snapshot

  4. The Department of Defense Very High Speed Integrated Circuit (VHSIC) Technology Availability Program Plan for the Committees on Armed Services United States Congress.

    DTIC Science & Technology

    1986-06-30

    features of computer aided design systems and statistical quality control procedures that are generic to chip sets and processes. RADIATION HARDNESS -The...System PSP Programmable Signal Processor SSI Small Scale Integration ." TOW Tube Launched, Optically Tracked, Wire Guided TTL Transistor Transitor Logic

  5. Playgrounds for Free: The Utilization of Used and Surplus Materials in Playground Construction.

    ERIC Educational Resources Information Center

    Hogan, Paul

    This book is a guide to setting up playgrounds from junk materials--used tires, cable reels, inner tubes, and railroad ties, among others--that are child-oriented rather than created primarily for the convenience of adult superintendents. Interwoven with many photographs and plans showing how to use the materials is the author's commentary--part…

  6. Green Schools Energy Project: A Step-by-Step Manual.

    ERIC Educational Resources Information Center

    Quigley, Gwen

    This publication contains a step-by-step guide for implementing an energy-saving project in local school districts: the installation of newer, more energy-efficient "T-8" fluorescent tube lights in place of "T-12" lights. Eleven steps are explained in detail: (1) find out what kind of lights the school district currently uses;…

  7. Pulmonary emphysema is a predictor of pneumothorax after CT-guided transthoracic pulmonary biopsies of pulmonary nodules.

    PubMed

    Lendeckel, Derik; Kromrey, Marie-Luise; Ittermann, Till; Schäfer, Sophia; Mensel, Birger; Kühn, Jens-Peter

    2017-01-01

    Pneumothoraces are the most frequently occurring complications of CT-guided percutaneous transthoracic pulmonary biopsies (PTPB). The aim of this study was to evaluate the influence of pre-diagnostic lung emphysema on the incidence and extent of pneumothoraces and to establish a risk stratification for the evaluation of the pre-procedure complication probability. CT-guided PTPB of 100 pre-selected patients (mean age 67.1±12.8 years) were retrospectively enrolled from a single center database of 235 PTPB performed between 2012-2014. Patients were grouped according to pneumothorax appearance directly after PTPB (group I: without pneumothorax, n = 50; group II: with pneumothorax, n = 50). Group II was further divided according to post-interventional treatment (group IIa: chest tube placement, n = 24; group IIb: conservative therapy, n = 26). For each patient pre-diagnostic percentage of emphysema was quantified using CT density analysis. Emphysema stages were compared between groups using bivariate analyses and multinomial logistic regression analyses. Emphysema percentage was significantly associated with the occurrence of post-interventional pneumothorax (p = 0.006). Adjusted for potential confounders (age, gender, lesion size and length of interventional pathway) the study yielded an OR of 1.07 (p = 0.042). Absolute risk of pneumothorax increased from 43.4% at an emphysema rate of 5% to 73.8% at 25%. No differences could be seen in patients with pneumothorax between percentage of emphysema and mode of therapy (p = 0.721). The rate of lung emphysema is proportionally related to the incidence of pneumothorax after CT-guided PTPB and allows pre-interventional risk stratification. There is no association between stage of emphysema and post-interventional requirement of chest tube placement.

  8. Pulmonary emphysema is a predictor of pneumothorax after CT-guided transthoracic pulmonary biopsies of pulmonary nodules

    PubMed Central

    Lendeckel, Derik; Kromrey, Marie-Luise; Ittermann, Till; Schäfer, Sophia; Mensel, Birger; Kühn, Jens-Peter

    2017-01-01

    Purpose Pneumothoraces are the most frequently occurring complications of CT-guided percutaneous transthoracic pulmonary biopsies (PTPB). The aim of this study was to evaluate the influence of pre-diagnostic lung emphysema on the incidence and extent of pneumothoraces and to establish a risk stratification for the evaluation of the pre-procedure complication probability. Material and methods CT-guided PTPB of 100 pre-selected patients (mean age 67.1±12.8 years) were retrospectively enrolled from a single center database of 235 PTPB performed between 2012–2014. Patients were grouped according to pneumothorax appearance directly after PTPB (group I: without pneumothorax, n = 50; group II: with pneumothorax, n = 50). Group II was further divided according to post-interventional treatment (group IIa: chest tube placement, n = 24; group IIb: conservative therapy, n = 26). For each patient pre-diagnostic percentage of emphysema was quantified using CT density analysis. Emphysema stages were compared between groups using bivariate analyses and multinomial logistic regression analyses. Results Emphysema percentage was significantly associated with the occurrence of post-interventional pneumothorax (p = 0.006). Adjusted for potential confounders (age, gender, lesion size and length of interventional pathway) the study yielded an OR of 1.07 (p = 0.042). Absolute risk of pneumothorax increased from 43.4% at an emphysema rate of 5% to 73.8% at 25%. No differences could be seen in patients with pneumothorax between percentage of emphysema and mode of therapy (p = 0.721). Conclusion The rate of lung emphysema is proportionally related to the incidence of pneumothorax after CT-guided PTPB and allows pre-interventional risk stratification. There is no association between stage of emphysema and post-interventional requirement of chest tube placement. PMID:28574995

  9. Tracheal tube cuff inflation guided by pressure volume loop closure associated with lower postoperative cuff-related complications: Prospective, randomized clinical trial.

    PubMed

    Almarakbi, Waleed A; Kaki, Abdullah M

    2014-07-01

    The main function of an endotracheal tube (ETT) cuff is to prevent aspiration. High cuff pressure is usually associated with postoperative complications. We tried to compare cuff inflation guided by pressure volume loop closure (PV-L) with those by just to seal technique (JS) and assess the postoperative incidence of sore throat, cough and hoarseness. In a prospective, randomized clinical trial, 100 patients' tracheas were intubated. In the first group (n = 50), ETT cuff inflation was guided by PV-L, while in the second group (n. = 50) the ETT cuff was inflated using the JS technique. Intracuff pressures and volumes were measured. The incidence of postoperative cuff-related complications was reported. Demographic data and durations of intubation were comparable between the groups. The use of PV-L was associated with a lesser amount of intracuff air [4.05 (3.7-4.5) vs 5 (4.8-5.5), P < 0.001] and lower cuff pressure than those in the JS group [18.25 (18-19) vs 33 (32-35), P ≤ 0.001]. The incidence of postextubation cuff-related complications was significantly less frequent among the PV-L group patients as compared with the JS group patients (P ≤ 0.009), except for hoarseness of voice, which was less frequent among the PV-L group, but not statistically significant (P ≤ 0.065). Multiple regression models for prediction of intra-cuff pressure after intubation and before extubation revealed a statistically significant association with the technique used for cuff inflation (P < 0.0001). The study confirms that PV-L-guided ETT cuff inflation is an effective way to seal the airway and associates with a lower ETT cuff pressure and lower incidence of cuff-related complications.

  10. Development of a Gas-Fed Pulse Detonation Research Engine

    NASA Technical Reports Server (NTRS)

    Litchford, Ron J.; Hutt, John (Technical Monitor)

    2001-01-01

    In response to the growing need for empirical data on pulse detonation engine performance and operation, NASA Marshall Space Flight Center has developed and placed into operation a low-cost gas-fed pulse detonation research engine. The guiding design strategy was to achieve a simple and flexible research apparatus, which was inexpensive to build and operate. As such, the engine was designed to operate as a heat sink device, and testing was limited to burst-mode operation with run durations of a few seconds. Wherever possible, maximum use was made of standard off-the-shelf industrial or automotive components. The 5-cm diameter primary tube is about 90-cm long and has been outfitted with a multitude of sensor and optical ports. The primary tube is fed by a coaxial injector through an initiator tube, which is inserted directly into the injector head face. Four auxiliary coaxial injectors are also integrated into the injector head assembly. All propellant flow is controlled with industrial solenoid valves. An automotive electronic ignition system was adapted for use, and spark plugs are mounted in both tubes so that a variety of ignition schemes can be examined. A microprocessor-based fiber-optic engine control system was developed to provide precise control over valve and ignition timing. Initial shakedown testing with hydrogen/oxygen mixtures verified the need for Schelkin spirals in both the initiator and primary tubes to ensure rapid development of the detonation wave. Measured pressure wave time-of-flight indicated detonation velocities of 2.4 km/sec and 2.2 km/sec in the initiator and primary tubes, respectively. These values implied a fuel-lean mixture corresponding to an H2 volume fraction near 0.5. The axial distribution for the detonation velocity was found to be essentially constant along the primary tube. Time-resolved thrust profiles were also acquired for both underfilled and overfilled tube conditions. These profiles are consistent with previous time-resolved measurements on single-cycle tubes where the thrust is found to peak as the detonation wave exits the tube, and decay as the tube blows down.

  11. Tip-localized receptors control pollen tube growth and LURE sensing in Arabidopsis.

    PubMed

    Takeuchi, Hidenori; Higashiyama, Tetsuya

    2016-03-10

    Directional control of tip-growing cells is essential for proper tissue organization and cell-to-cell communication in animals and plants. In the sexual reproduction of flowering plants, the tip growth of the male gametophyte, the pollen tube, is precisely guided by female cues to achieve fertilization. Several female-secreted peptides have recently been identified as species-specific attractants that directly control the direction of pollen tube growth. However, the method by which pollen tubes precisely and promptly respond to the guidance signal from their own species is unknown. Here we show that tip-localized pollen-specific receptor-like kinase 6 (PRK6) with an extracellular leucine-rich repeat domain is an essential receptor for sensing of the LURE1 attractant peptide in Arabidopsis thaliana under semi-in-vivo conditions, and is important for ovule targeting in the pistil. PRK6 interacted with pollen-expressed ROPGEFs (Rho of plant guanine nucleotide-exchange factors), which are important for pollen tube growth through activation of the signalling switch Rho GTPase ROP1 (refs 7, 8). PRK6 conferred responsiveness to AtLURE1 in pollen tubes of the related species Capsella rubella. Furthermore, our genetic and physiological data suggest that PRK6 signalling through ROPGEFs and sensing of AtLURE1 are achieved in cooperation with the other PRK family receptors, PRK1, PRK3 and PRK8. Notably, the tip-focused PRK6 accumulated asymmetrically towards an external AtLURE1 source before reorientation of pollen tube tip growth. These results demonstrate that PRK6 acts as a key membrane receptor for external AtLURE1 attractants, and recruits the core tip-growth machinery, including ROP signalling proteins. This work provides insights into the orchestration of efficient pollen tube growth and species-specific pollen tube attraction by multiple receptors during male-female communication.

  12. Evaluation of chest tube administration of tissue plasminogen activator to treat retained hemothorax.

    PubMed

    Stiles, P J; Drake, Rachel M; Helmer, Stephen D; Bjordahl, Paul M; Haan, James M

    2014-06-01

    When retained hemothorax occurs, video-assisted thoracoscopy or thoracotomy is performed, but recently, tissue plasminogen activator (tPA) has been used. This study evaluated intrapleural tPA use for retained traumatic hemothoraces. A retrospective review was conducted of trauma patients treated with intrapleural tPA for retained hemothorax. Data included demographics, past medical and surgical histories, injury details, treatment details, and outcomes. Seven patients (median age = 47 years, male = 6, blunt trauma = 6) met study criteria. All patients received a chest tube. Six patients later received computed tomography-guided drains for tPA infusion. Number of tPA treatments per patient varied from 1 to 5. Median total tPA dosage was 24 mg. Median time from injury to chest tube placement was 11 days and from chest tube placement to first tPA treatment was 4 days. No patients required a video-assisted thoracoscopy; however, 1 patient required thoracotomy. There were no deaths or bleeding complications attributed to intrapleural tPA. Although future studies are needed to identify optimum treatment guidelines, intrapleural tPA appears to be a safe and efficacious treatment option. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Steam Generator tube integrity -- US Nuclear Regulatory Commission perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, E.L.; Sullivan, E.J.

    1997-02-01

    In the US, the current regulatory framework was developed in the 1970s when general wall thinning was the dominant degradation mechanism; and, as a result of changes in the forms of degradation being observed and improvements in inspection and tube repair technology, the regulatory framework needs to be updated. Operating experience indicates that the current U.S. requirements should be more stringent in some areas, while in other areas they are overly conservative. To date, this situation has been dealt with on a plant-specific basis in the US. However, the NRC staff is now developing a proposed steam generator rule asmore » a generic framework for ensuring that the steam generator tubes are capable of performing their intended safety functions. This paper discusses the current U.S. regulatory framework for assuring steam generator (SG) tube integrity, the need to update this regulatory framework, the objectives of the new proposed rule, the US Nuclear Regulatory Commission (NRC) regulatory guide (RG) that will accompany the rule, how risk considerations affect the development of the new rule, and some outstanding issues relating to the rule that the NRC is still dealing with.« less

  14. Interactive-rate Motion Planning for Concentric Tube Robots

    PubMed Central

    Torres, Luis G.; Baykal, Cenk; Alterovitz, Ron

    2014-01-01

    Concentric tube robots may enable new, safer minimally invasive surgical procedures by moving along curved paths to reach difficult-to-reach sites in a patient’s anatomy. Operating these devices is challenging due to their complex, unintuitive kinematics and the need to avoid sensitive structures in the anatomy. In this paper, we present a motion planning method that computes collision-free motion plans for concentric tube robots at interactive rates. Our method’s high speed enables a user to continuously and freely move the robot’s tip while the motion planner ensures that the robot’s shaft does not collide with any anatomical obstacles. Our approach uses a highly accurate mechanical model of tube interactions, which is important since small movements of the tip position may require large changes in the shape of the device’s shaft. Our motion planner achieves its high speed and accuracy by combining offline precomputation of a collision-free roadmap with online position control. We demonstrate our interactive planner in a simulated neurosurgical scenario where a user guides the robot’s tip through the environment while the robot automatically avoids collisions with the anatomical obstacles. PMID:25436176

  15. Mechanics of neurulation: From classical to current perspectives on the physical mechanics that shape, fold, and form the neural tube.

    PubMed

    Vijayraghavan, Deepthi S; Davidson, Lance A

    2017-01-30

    Neural tube defects arise from mechanical failures in the process of neurulation. At the most fundamental level, formation of the neural tube relies on coordinated, complex tissue movements that mechanically transform the flat neural epithelium into a lumenized epithelial tube (Davidson, 2012). The nature of this mechanical transformation has mystified embryologists, geneticists, and clinicians for more than 100 years. Early embryologists pondered the physical mechanisms that guide this transformation. Detailed observations of cell and tissue movements as well as experimental embryological manipulations allowed researchers to generate and test elementary hypotheses of the intrinsic and extrinsic forces acting on the neural tissue. Current research has turned toward understanding the molecular mechanisms underlying neurulation. Genetic and molecular perturbation have identified a multitude of subcellular components that correlate with cell behaviors and tissue movements during neural tube formation. In this review, we focus on methods and conceptual frameworks that have been applied to the study of amphibian neurulation that can be used to determine how molecular and physical mechanisms are integrated and responsible for neurulation. We will describe how qualitative descriptions and quantitative measurements of strain, force generation, and tissue material properties as well as simulations can be used to understand how embryos use morphogenetic programs to drive neurulation. Birth Defects Research 109:153-168, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. YouTube videos as a teaching tool and patient resource for infantile spasms.

    PubMed

    Fat, Mary Jane Lim; Doja, Asif; Barrowman, Nick; Sell, Erick

    2011-07-01

    The purpose of this study was to assess YouTube videos for their efficacy as a patient resource for infantile spasms. Videos were searched using the terms infantile spasm, spasm, epileptic spasm, and West syndrome. The top 25 videos under each term were selected according to set criteria. Technical quality, diagnosis of infantile spasms, and suitability as a teaching resource were assessed by 2 neurologists using the Medical Video Rating Scale. There were 5858 videos found. Of the 100 top videos, 46% did not meet selection criteria. Mean rating for technical quality was 4.0 of 5 for rater 1 and 3.9 of 5 for rater 2. Raters found 60% and 64% of videos to accurately portray infantile spasms, respectively, with significant agreement (Cohen κ coefficient = 0.75, P < .001). Ten videos were considered excellent examples (grading of 5 of 5) by at least 1 rater. YouTube may be used as an excellent patient resource for infantile spasms if guided search practices are followed.

  17. Standardization and Optimization of Computed Tomography Protocols to Achieve Low-Dose

    PubMed Central

    Chin, Cynthia; Cody, Dianna D.; Gupta, Rajiv; Hess, Christopher P.; Kalra, Mannudeep K.; Kofler, James M.; Krishnam, Mayil S.; Einstein, Andrew J.

    2014-01-01

    The increase in radiation exposure due to CT scans has been of growing concern in recent years. CT scanners differ in their capabilities and various indications require unique protocols, but there remains room for standardization and optimization. In this paper we summarize approaches to reduce dose, as discussed in lectures comprising the first session of the 2013 UCSF Virtual Symposium on Radiation Safety in Computed Tomography. The experience of scanning at low dose in different body regions, for both diagnostic and interventional CT procedures, is addressed. An essential primary step is justifying the medical need for each scan. General guiding principles for reducing dose include tailoring a scan to a patient, minimizing scan length, use of tube current modulation and minimizing tube current, minimizing-tube potential, iterative reconstruction, and periodic review of CT studies. Organized efforts for standardization have been spearheaded by professional societies such as the American Association of Physicists in Medicine. Finally, all team members should demonstrate an awareness of the importance of minimizing dose. PMID:24589403

  18. Established enteral nutrition pathway in a severe acute pancreatitis patient with duodenum fistula: a case report.

    PubMed

    Li, G; Shen, X; Ke, L; Tong, Z; Li, W

    2015-10-01

    Enteral feeding is the preferred way to provide nutritional support in patients with high nutritional risk but relatively normal gastrointestinal function; thus, establishing a safe and a reliable pathway of enteral nutrition (EN) is of great importance. There are many techniques for placing the feeding tube, such as blind placement at bedside, assisting by fluoroscopy and endoscopy, surgical and so on. Despite these variable techniques, it is still difficult to obtain the pathway for EN in some specific patients. Here, we present a recent case of infected pancreatic/peripancreatic necrosis complicated by a duodenal enteric fistula in whom we establish the feeding pathway extraordinarily. Briefly, after several failed attempts of placing the nasojejunal feeding tube, a jejunal feeding tube was placed percutaneously guided by computed tomography, and EN was successfully applied thereafter. With the implementation of EN, duodenal fistula healed without surgical intervention. As EN is pivotal for the recovery of duodenal fistula, this novel approach could be beneficial in selected patients.

  19. Micromachined actuators/sensors for intratubular positioning/steering

    DOEpatents

    Lee, Abraham P.; Krulevitch, Peter A.; Northrup, M. Allen; Trevino, Jimmy C.

    1998-01-01

    Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems.

  20. Microvalve

    DOEpatents

    Lee, A.P.; Krulevitch, P.A.; Northrup, M.A.; Trevino, J.C.

    1998-10-13

    Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems. 14 figs.

  1. Microvalve

    DOEpatents

    Lee, Abraham P.; Krulevitch, Peter A.; Northrup, M. Allen; Trevino, Jimmy C.

    1998-01-01

    Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems.

  2. User-guided automated segmentation of time-series ultrasound images for measuring vasoreactivity of the brachial artery induced by flow mediation

    NASA Astrophysics Data System (ADS)

    Sehgal, Chandra M.; Kao, Yen H.; Cary, Ted W.; Arger, Peter H.; Mohler, Emile R.

    2005-04-01

    Endothelial dysfunction in response to vasoactive stimuli is closely associated with diseases such as atherosclerosis, hypertension and congestive heart failure. The current method of using ultrasound to image the brachial artery along the longitudinal axis is insensitive for measuring the small vasodilatation that occurs in response to flow mediation. The goal of this study is to overcome this limitation by using cross-sectional imaging of the brachial artery in conjunction with the User-Guided Automated Boundary Detection (UGABD) algorithm for extracting arterial boundaries. High-resolution ultrasound imaging was performed on rigid plastic tubing, on elastic rubber tubing phantoms with steady and pulsatile flow, and on the brachial artery of a healthy volunteer undergoing reactive hyperemia. The area of cross section of time-series images was analyzed by UGABD by propagating the boundary from one frame to the next. The UGABD results were compared by linear correlation with those obtained by manual tracing. UGABD measured the cross-sectional area of the phantom tubing to within 5% of the true area. The algorithm correctly detected pulsatile vasomotion in phantoms and in the brachial artery. A comparison of area measurements made using UGABD with those made by manual tracings yielded a correlation of 0.9 and 0.8 for phantoms and arteries, respectively. The peak vasodilatation due to reactive hyperemia was two orders of magnitude greater in pixel count than that measured by longitudinal imaging. Cross-sectional imaging is more sensitive than longitudinal imaging for measuring flow-mediated dilatation of brachial artery, and thus may be more suitable for evaluating endothelial dysfunction.

  3. Military Applications of Fiber Optics Technology

    DTIC Science & Technology

    1989-05-01

    Research Projects Agency DNA Defense Nuclear Agency EMI Electromagnetic interference EMP Electromagnetic pulse FET Field effect transistor FOFA Follow...Organization SEED Self electro-optic effect device TBM Tactical ballistic missile TOW Tube launched, optically tracked, wire-guided UAV Unmanned aerial vehicle...systems, coupled with novel but effective transducing technology, have set the stage for a powerful class of fiber optic sensors. 8 Optical fibers have

  4. Design of a magnetic shielding system for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, Z. Q.; Chen, Z. J.; Xie, X. F.

    2014-11-15

    The novel neutron spectrometer TOFED (Time of Flight Enhanced Diagnostics), comprising 90 individual photomultiplier tubes coupled with 85 plastic scintillation detectors through light guides, has been constructed and installed at Experimental Advanced Superconducting Tokamak. A dedicated magnetic shielding system has been constructed for TOFED, and is designed to guarantee the normal operation of photomultiplier tubes in the stray magnetic field leaking from the tokamak device. Experimental measurements and numerical simulations carried out employing the finite element method are combined to optimize the design of the magnetic shielding system. The system allows detectors to work properly in an external magnetic fieldmore » of 200 G.« less

  5. Neutron capture therapy with deep tissue penetration using capillary neutron focusing

    DOEpatents

    Peurrung, Anthony J.

    1997-01-01

    An improved method for delivering thermal neutrons to a subsurface cancer or tumor which has been first doped with a dopant having a high cross section for neutron capture. The improvement is the use of a guide tube in cooperation with a capillary neutron focusing apparatus, or neutron focusing lens, for directing neutrons to the tumor, and thereby avoiding damage to surrounding tissue.

  6. YouTube War: Fighting in a World of Cameras in Every Cell Phone and Photoshop on Every Computer

    DTIC Science & Technology

    2009-11-01

    free MovieMaker 2 program that Microsoft includes with its Windows XP operating system. Mike Wendland, “From ENG to SNG : TV Technology for Covering the...the deployed soldier. 51. Wendland, “From ENG to SNG .” 52. This is based in part on the typology in Ben Venzke, “Jihadi Master Video Guide, JMVG

  7. 2.75-Inch Motor Manufacturing Waste Minimization Project

    DTIC Science & Technology

    2006-06-19

    Certification Program FEM Finite element model HFMI Highly Filled Materials Institute HOE Heat of explosion ICT Institute of Chemical Technology IHDIV...Trinitrotoluene TOW Tube-launched, optically tracked, wire-guided missile TPE Thermoplastic elastomers TSE Twin screw mixer/extruder VPDES Virginia Pollution...extruded and test fired. 1996–1997 Inert TPE Processing: Thermoplastic elastomers (TPE) are ideal binders for “green energetics” because they do

  8. Imaging hydraulic fractures at Median Tectonic Line, Japan using multiply generated and scattered tube waves in a shallow VSP experiment

    NASA Astrophysics Data System (ADS)

    Minato, Shohei; Ghose, Ranajit; Tsuji, Takeshi; Ikeda, Michiharu; Onishi, Kozo

    2016-04-01

    Tube waves are low frequency guided waves that propagate along a fluid-filled borehole. The analysis of tube waves is a promising approach to image and characterize hydraulic fractures intersecting a borehole. It exploits tube waves generated by an external seismic wavefield which compresses fractures and injects fluid into the borehole. It also utilizes the attenuation of tube waves due to fluid exchange between the fracture and the borehole, which creates scattered waves (reflection and transmission). Conventional approaches consider tube waves due to a single fracture. However, when the spacing between multiple fractures is short relative to the wavelength of the tube waves, the generated and scattered tube waves interfere with each other, making it difficult to isolate the effect of a single fracture. The analysis of closely spaced fractures is important in highly fractured areas, such as a fault zone. In this study, we explore the possibility of prediction and utilization of generated and scattered tube waves due to multiple fractures. We derive a new integral equation of the full tube wavefield using 1D wavefield representation theory incorporating nonwelded interfaces. We adapt the recent developments in modeling tube wave generation/scattering at a fracture. In these models, a fracture is represented as a parallel wall or a thin poloelastic layer. This allowed us to consider the effects of a dynamic fracture aperture with fracture compliances and the permeability. The representation also leads to a new imaging method for the hydraulic fractures, using multiply-generated and scattered tube waves. This is achieved by applying an inverse operator to the observed tube waves, which focuses the tube waves to the depth where they are generated and/or scattered. The inverse operator is constructed by a tube wave Green's function with a known propagation velocity. The Median Tectonic Line (MTL) is the most significant fault in Japan, extending NE-SW for over 1000 km across the Japanese Islands. We observed multiple tube waves in a P-wave VSP experiment in a 250 m deep, vertical borehole located on the MTL at Shikoku, Japan. The borehole televiewer and the core studies show that below 40 m depth, the Sambagawa metamorphic rocks contain highly fractured zones which consist of more than 100 open fractures and more than 30 cataclasites. We predict the full tube wavefield using the values of fracture depth and thickness known from the borehole televiewer. We model the open fractures as parallel-wall fractures and the cataclasites as thin poroelastic layers. Furthermore, we estimate the depth of the hydraulic fractures by applying the inverse operator. The results show that the tube waves could be generated and scattered at these permeable structures. Our preliminary results also indicate the possibility that the effect of the open fractures is more dominant in the generation and scattering of tube waves than that of the cataclasites in this field. The formulation and the results presented in this study and the following discussion will be useful in analysis of tube waves in highly fractured zones, in order to localize and characterize hydraulic fractures.

  9. Comparative transcriptome analysis links distinct peritoneal tumor spread types, miliary and non-miliary, with putative origin, tubes and ovaries, in high grade serous ovarian cancer.

    PubMed

    Auer, Katharina; Bachmayr-Heyda, Anna; Aust, Stefanie; Grunt, Thomas W; Pils, Dietmar

    2017-03-01

    High grade serous ovarian cancer (HGSOC) is characterized by extensive local, i.e. peritoneal, tumor spread, manifested in two different clinical presentations, miliary (many millet sized peritoneal implants) and non-miliary (few large exophytically growing peritoneal nodes), and an overall unfavorable outcome. HGSOC is thought to arise from fallopian tube secretory epithelial cells, via so called serous tubal intraepithelial carcinomas (STICs) but an ovarian origin was never ruled out for at least some cases. Comparative transcriptome analyses of isolated tumor cells from fresh HGSOC tissues and (immortalized) ovarian surface epithelial and fallopian tube secretory epithelial cell lines revealed a close relation between putative origin and tumor spread characteristic, i.e. miliary from tubes and non-miliary from ovaries. The latter were characterized by more mesenchymal cell characteristics, more adaptive tumor immune infiltration, and a favorable overall survival. Several molecular sub-classification systems (Crijns' overall survival signature, Yoshihara's subclasses, and a collagen-remodeling signature) seem to already indicate origin. Putative origin alone is a significant independent predictor for HGSOC outcome, validated in independent patient cohorts. Characteristics of both spread types could guide development of new targeted therapeutics, which are urgently needed. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Efficiency of irrigation water application in sugarcane cultivation in Pakistan.

    PubMed

    Watto, Muhammad Arif; Mugera, Amin W

    2015-07-01

    Diminishing irrigation water supplies are threatening the sustainability of irrigated agriculture in Pakistan. Within the context of dwindling water resources and low agricultural water productivity, it is imperative to improve efficiency in agricultural production and to make efficient use of available water resources. This study employs a non-parametric approach to estimate the extent of technical and irrigation water efficiency in sugarcane cultivation in Pakistan. The mean technical efficiency score is 0.96 for tube-well owners whereas it is 0.94 for water buyers. The mean irrigation water efficiency score is 0.86 for tube-well owners whereas it is 0.72 for water buyers. We find that across all farms, 59% of the tube-well owners and 45% of the water buyers are fully technically efficient, whereas only 36% of the tube-well owners and 30% of the water buyer are fully efficient in irrigation water use. This study finds that sugarcane growers are operating at fairly high technical efficiency levels. But, there is considerable potential to improve irrigation water efficiency. This study proposes expanding the role of agricultural extension services from merely agronomic grounds to guide farmers to undertake cost benefit analysis of the available production technology, would help achieve higher efficiency levels. © 2014 Society of Chemical Industry.

  11. Formulation of consumables management models. Volume 2: Mission planning processor user guide

    NASA Technical Reports Server (NTRS)

    Daly, J. K.; Torian, J. G.

    1978-01-01

    A user guide for the MPP (Mission Planning Processor) is presented. The MPP is used in the evaluation of particular missions, with appropriate display and storage of related consumables data. Design goals are accomplished by the use of an on-line/demand mode computer terminal Cathode Ray Tube Display. The process is such that the user merely adds specific mission/flight functions to a skeleton flight and/or alters the skeleton. The skeleton flight includes operational aspects from prelaunch through ground support equipment connect after rollout as required to place the STS (Space Transportation System) in a parking orbit, maintain the spacecraft and crew for the stated on-orbit period and return.

  12. Micromachined actuators/sensors for intratubular positioning/steering

    DOEpatents

    Lee, A.P.; Krulevitch, P.A.; Northrup, M.A.; Trevino, J.C.

    1998-06-30

    Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems. 14 figs.

  13. [An expedient semi-automatic procedure for the preparation of large quantities of bioindicators especially for use in gas sterilization processes].

    PubMed

    Spicher, G; Borchers, U

    1985-06-01

    Bioindicators serve to test the efficacy of disinfection and sterilization procedures. Such indicators mostly consist of a support (filter paper, as a rule) to which micro-organisms have been fixed by drying. The authors have used a thread as support and a special apparatus for semi-automatic preparation of the bioindicators. The components of the device are either commercially available or may be prepared from commercially available material without difficulty. The principle of the method is as follows: The thread serving as the support is drawn slowly, at constant speed, through the suspension of test organisms and dried in an air stream immediately afterwards. The apparatus consists of a cylindrical glass tube of a few centimeters in diameter, an electric motor slowly rotating the cylinder, a fan, a magnetic stirrer, and an ice-water bath. A small vial containing the germ suspension is immersed in the ice-water bath. The vial is sealed by a screw cap with two glass tubes of about 3 mm inner diameter passing through it. One of the glass tubes being bent in its upper part reaches far down into the vial to leave just enough play for free rotation of a magnetic stirring rod. This tube serves to introduce the thread into the germ suspension. The second straight tube does not reach as far down as the first one. Its lower opening should not be immersed in the germ suspension. This tube serves as a guide for the returning thread. Preparation begins by winding the thread to be soaked with the suspension around the cylinder.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. A tetrahedron beam computed tomography benchtop system with a multiple pixel field emission x-ray tube.

    PubMed

    Xu, Xiaochao; Kim, Joshua; Laganis, Philip; Schulze, Derek; Liang, Yongguang; Zhang, Tiezhi

    2011-10-01

    To demonstrate the feasibility of Tetrahedron Beam Computed Tomography (TBCT) using a carbon nanotube (CNT) multiple pixel field emission x-ray (MPFEX) tube. A multiple pixel x-ray source facilitates the creation of novel x-ray imaging modalities. In a previous publication, the authors proposed a Tetrahedron Beam Computed Tomography (TBCT) imaging system which comprises a linear source array and a linear detector array that are orthogonal to each other. TBCT is expected to reduce scatter compared with Cone Beam Computed Tomography (CBCT) and to have better detector performance. Therefore, it may produce improved image quality for image guided radiotherapy. In this study, a TBCT benchtop system has been developed with an MPFEX tube. The tube has 75 CNT cold cathodes, which generate 75 x-ray focal spots on an elongated anode, and has 4 mm pixel spacing. An in-house-developed, 5-row CT detector array using silicon photodiodes and CdWO(4) scintillators was employed in the system. Hardware and software were developed for tube control and detector data acquisition. The raw data were preprocessed for beam hardening and detector response linearity and were reconstructed with an FDK-based image reconstruction algorithm. The focal spots were measured at about 1 × 2 mm(2) using a star phantom. Each cathode generates around 3 mA cathode current with 2190 V gate voltage. The benchtop system is able to perform TBCT scans with a prolonged scanning time. Images of a commercial CT phantom were successfully acquired. A prototype system was developed, and preliminary phantom images were successfully acquired. MPFEX is a promising x-ray source for TBCT. Further improvement of tube output is needed in order for it to be used in clinical TBCT systems.

  15. Focusing electrode and coaxial reflector used for reducing the guiding magnetic field of the Ku-band foilless transit-time oscillator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ling, Junpu; Zhang, Jiande; He, Juntao, E-mail: hejuntao12@163.com

    2014-08-15

    Based on the theoretical analysis of the intense relativistic electron beam propagation in the coaxial drift-tube, a focusing electrode and a coaxial reflector is proposed to lessen the demand of the coaxial Ku-band foilless transit-time oscillator (TTO) for the guiding magnetic field. Moreover, a Ku-band TTO with the focusing electrode and the coaxial reflector is designed and studied by particle in cell simulation. When the diode voltage is 390 kV, the beam current 7.8 kA, and the guiding magnetic field is only 0.3 T, the device can output 820 MW microwave pulse at 14.25 GHz by means of the simulation.more » However, for the device without them, the output power is only 320 MW. The primary experiments are also carried out. When the guiding magnetic field is 0.3 T, the output power of the device with the focusing electrode and the coaxial reflector is double that of the one without them. The simulation and experimental results prove that the focusing electrode and the coaxial reflector are effective on reducing the guiding magnetic field of the device.« less

  16. T-tube drainage of the common bile duct choleperitoneum: etiology and management.

    PubMed

    Daldoul, S; Moussi, A; Zaouche, A

    2012-06-01

    External drainage of the common bile duct by placement of a T-tube is a common practice after choledochotomy. This practice may result in the specific complication of bile peritonitis due to leakage after removal of the T-tube. This complication has multiple causes: some are patient-related (corticotherapy, chemotherapy, ascites), and others are due to technical factors (inappropriate suturing of the drain to the ductal wall, minimal inflammatory reaction related to some drain materials). The clinical presentation is quite variable depending on the amount and rapidity of intra-peritoneal spread of of bile leakage. Abdominal ultrasound (US), with US-guided needle aspiration and occasionally Technetium(99) scintigraphy are useful for diagnosis. Traditional therapy consists of surgical intervention including peritoneal lavage and re-intubation of the choledochal fistulous tract to allow for a further period of external drainage. When leakage is walled off and well-tolerated, a more nuanced and less invasive conservative therapy may combine percutaneous drainage with endoscopic placement of a trans-ampullary biliary drainage. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  17. Use of prismatic films to control light distribution

    NASA Technical Reports Server (NTRS)

    Kneipp, K. G.

    1994-01-01

    Piping light for illumination purposes is a concept which has been around for a long time. In fact, it was the subject of an 1881 United States patent which proposed the use of mirrors inside a tube to reflect light from wall to wall down the tube. The use of conventional mirrors for this purpose, however, has not worked because mirrors do not reflect well enough. On the other hand, optical fibers composed of certain glasses or plastics are known to transport light much more efficiently. The light that enters is reflected back and forth within the walls of the fiber until it reaches the other end. This is possible by means of a principle known as 'total internal reflection'. No light escapes through the walls and very little is absorbed in the bulk of the fiber. However, while optical fibers are very efficient in transporting light, they are impractical for transporting large quantities of light. Lorne Whitehead, as a student at the University of British Columbia, recognized that prismatic materials could be used to create a 'prism light guide', a hollow structure that can efficiently transport large quantities of light. This invention is a pipe whose transparent walls are formed on the outside into precise prismatic facets. The facets are efficient total internal reflection mirrors which prevent light travelling down the guide from escaping. Very little light is absorbed by the pipe because light travels primarily in the air space within the hollow guide. And, because the guide is hollow, weight and cost factors are much more favorable than would be the case with very large solid fibers. Recent advances in precision micromachining, polymer processing, and certain other manufacturing technologies have made the development of OLF (Optical Lighting Film) possible. The process is referred to as 'microreplication' and has been found to have broad applicability in a number of diverse product areas.

  18. Air-Q® versus LMA Fastrach™ for fiberoptic-guided intubation: A randomized cross-over manikin trial.

    PubMed

    Portas, M; Canal, M I; Barrio, M; Alonso, M; Cabrerizo, P; López-Gil, M; Zaballos, M

    2018-03-01

    Airway management is still a major cause of anesthesia-associated morbidity and mortality. Supraglottic devices are recommended in difficult airway management guidelines. The aim of this study was to compare the performance of the Air-Q ® and the LMA Fastrach™ for fiberoptic guided tracheal intubation. Thirty-three anesthesia trainees participated in this randomized crossover study. Time to insert the dedicated airways (insertion of the airway into the manikin and delivery of two breaths), time to tracheal intubation (fiberoptic-guided tracheal intubation), time to remove the dedicated airway (removal of the Air-Q ® /LMA Fastrach™ over the tracheal tube) and the opinion of the ease of use of the anesthesia trainees were measured. There was 100% success rate for tracheal intubation with both devices on the first attempt. Time to insert the dedicated device and deliver two breaths was 10±3s for the Air-Q ® and 11±3s for the LMA Fastrach™, P=.07. Time taken to intubate the trachea was shorter with the air-Q ® , 38±15 s, than with the LMA Fastrach™, 47±19s, P=.017. Overall procedure time was significantly shorter with the Air-Q ® as compared with the LMA Fastrach™, with a mean time of 74±21s and 87±28s respectively, P=.002. Air-Q ® removal was considered easier than LMA Fastrach™ removal, P=.005. There were no tube dislodgements during the removal of the dedicated airways. Inexperienced anesthesia residents can perform fiberoptic-guided intubation through Air-Q ® and LMA Fastrach™ in a clinically acceptable time with high success. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Adhesives: Test Method, Group Assignment, and Categorization Guide for High-Loading-Rate Applications Preparation and Testing of Single Lap Joints (Ver. 2.2, Unlimited)

    DTIC Science & Technology

    2016-04-01

    Gerard Chaney, and Charles Pergantis Weapons and Materials Research Directorate, ARL Coatings, Corrosion, and Engineered Polymers Branch (CCEPB...SUBJECT TERMS single lap joint, adhesive, sample preparation, testing, database, metadata, material pedigree, ISO 16. SECURITY CLASSIFICATION OF: 17...temperature/water immersion conditioning test for lap-joint test specimens using the test tubes and convection oven method

  20. Neutron capture therapy with deep tissue penetration using capillary neutron focusing

    DOEpatents

    Peurrung, A.J.

    1997-08-19

    An improved method is disclosed for delivering thermal neutrons to a subsurface cancer or tumor which has been first doped with a dopant having a high cross section for neutron capture. The improvement is the use of a guide tube in cooperation with a capillary neutron focusing apparatus, or neutron focusing lens, for directing neutrons to the tumor, and thereby avoiding damage to surrounding tissue. 1 fig.

  1. Electric Field Comparison between Microelectrode Recording and Deep Brain Stimulation Systems—A Simulation Study

    PubMed Central

    Johansson, Johannes; Wårdell, Karin; Hemm, Simone

    2018-01-01

    The success of deep brain stimulation (DBS) relies primarily on the localization of the implanted electrode. Its final position can be chosen based on the results of intraoperative microelectrode recording (MER) and stimulation tests. The optimal position often differs from the final one selected for chronic stimulation with the DBS electrode. The aim of the study was to investigate, using finite element method (FEM) modeling and simulations, whether lead design, electrical setup, and operating modes induce differences in electric field (EF) distribution and in consequence, the clinical outcome. Finite element models of a MER system and a chronic DBS lead were developed. Simulations of the EF were performed for homogenous and patient-specific brain models to evaluate the influence of grounding (guide tube vs. stimulator case), parallel MER leads, and non-active DBS contacts. Results showed that the EF is deformed depending on the distance between the guide tube and stimulating contact. Several parallel MER leads and the presence of the non-active DBS contacts influence the EF distribution. The DBS EF volume can cover the intraoperatively produced EF, but can also extend to other anatomical areas. In conclusion, EF deformations between stimulation tests and DBS should be taken into consideration as they can alter the clinical outcome. PMID:29415442

  2. The Characteristics of Thin Magnetic Flux Tubes in the Lower Solar Atmosphere Observed by Hinode/SOT in the G band and in Ca II H Bright Points

    NASA Astrophysics Data System (ADS)

    Xiong, Jianping; Yang, Yunfei; Jin, Chunlan; Ji, Kaifan; Feng, Song; Wang, Feng; Deng, Hui; Hu, Yu

    2017-12-01

    Photospheric bright points (PBPs) and chromospheric bright points (CBPs) reflect the cross sections of magnetic flux tubes at different heights of the lower solar atmosphere. We aim to study the fine 3D structures and transportation dynamics of the magnetic flux tubes using G-band and simultaneous Ca II H image-series from the Solar Optical Telescope (SOT) on board Hinode. A 3D track-while-detect method is proposed to detect and track PBPs and CBPs. The mean values of equivalent diameters, maximum intensity contrasts, transverse velocities, motion ranges, motion types, and diffusion indices of PBPs and CBPs are 180 ± 20 and 210 ± 30 km, 1.0+/- 0.1< {I}{QS\\_G}> and 1.2+/- 0.1< {I}{QS\\Ca}> , 1.6 ± 0.8 and 2.7 ± 1.4 km s‑1, 1.5 ± 0.6 and 1.7 ± 0.8, 0.8 ± 0.2 and 0.6 ± 0.2, and 1.7 ± 0.7 and 1.3 ± 0.7, respectively. Moreover, the ratios of each CBP characteristics to its corresponding PBP are derived to explore the change rates of the flux tubes. The corresponding ratios are 1.2 ± 0.2, 1.2 ± 0.1, 1.9 ± 0.1, 1.4 ± 0.3, 0.7 ± 0.2, and 0.9 ± 0.4, respectively. The statistical results imply that the majority magnetic flux tubes expand slightly with increasing solar height, look brighter than their surroundings, show a higher transverse velocity, a wider motion range, and a more erratic path, but the majority of the flux tubes diffuse slightly slower. The phenomenon might be explained by the conservation of momentum combined with a decrease in density. The more erratic path leads to a swing or twist of the flux tubes and therefore guides magnetohydrodynamic waves.

  3. Virtually fabricated guide for placement of the C-tube miniplate.

    PubMed

    Paek, Janghyun; Jeong, Do-Min; Kim, Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2014-05-01

    This paper introduces a virtually planned and stereolithographically fabricated guiding system that will allow the clinician to plan carefully for the best location of the device and to achieve an accurate position without complications. The scanned data from preoperative dental casts were edited to obtain preoperative 3-dimensional (3D) virtual models of the dentition. After the 3D virtual models were repositioned, the 3D virtual surgical guide was fabricated. A surgical guide was created onscreen, and then these virtual guides were materialized into real ones using the stereolithographic technique. Whereas the previously described guide required laboratory work to be performed by the orthodontist, our technique is more convenient because the laboratory work is done remotely by computer-aided design/computer-aided manufacturing technology. Because the miniplate is firmly held in place as the patient holds his or her mandibular teeth against the occlusal pad of the surgical guide, there is no risk that the miniscrews can slide on the bone surface during placement. The software program (2.5-dimensional software) in this study combines 2-dimensional cephalograms with 3D virtual dental models. This software is an effective and efficient alternative to 3D software when 3D computed tomography data are not available. To confidently and safely place a miniplate with screw fixation, a simple customized guide for an orthodontic miniplate was introduced. The use of a custom-made, rigid guide when placing miniplates will minimize complications such as vertical mislocation or slippage of the miniplate during placement. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  4. Design constraints of the LST fine guidance sensor

    NASA Technical Reports Server (NTRS)

    Wissinger, A. B.

    1975-01-01

    The LST Fine Guidance Sensor design is shaped by the rate of occurrence of suitable guide stars, the competition for telescope focal plane space with the Science Instruments, and the sensitivity of candidate image motion sensors. The relationship between these parameters is presented, and sensitivity to faint stars is shown to be of prime importance. An interferometric technique of image motion sensing is shown to have improved sensitivity and, therefore, a reduced focal plane area requirement in comparison with other candidate techniques (image-splitting prism and image dissector tube techniques). Another design requirement is speed in acquiring the guide star in order to maximize the time available for science observations. The design constraints are shown parametrically, and modelling results are presented.

  5. Guided growth of large-scale, horizontally aligned arrays of single-walled carbon nanotubes and their use in thin-film transistors.

    PubMed

    Kocabas, Coskun; Hur, Seung-Hyun; Gaur, Anshu; Meitl, Matthew A; Shim, Moonsub; Rogers, John A

    2005-11-01

    A convenient process for generating large-scale, horizontally aligned arrays of pristine, single-walled carbon nanotubes (SWNTs) is described. The approach uses guided growth, by chemical vapor deposition (CVD), of SWNTs on miscut single-crystal quartz substrates. Studies of the growth reveal important relationships between the density and alignment of the tubes, the CVD conditions, and the morphology of the quartz. Electrodes and dielectrics patterned on top of these arrays yield thin-film transistors that use the SWNTs as effective thin-film semiconductors. The ability to build high-performance devices of this type suggests significant promise for large-scale aligned arrays of SWNTs in electronics, sensors, and other applications.

  6. Device for Automated Cutting and Transfer of Plant Shoots

    NASA Technical Reports Server (NTRS)

    Cipra, Raymond; Das, Hari; Ali, Khaled; Hong, Dennis

    2003-01-01

    A device that enables the automated cutting and transfer of plant shoots is undergoing development for use in the propagation of plants in a nursery or laboratory. At present, it is standard practice for a human technician to use a knife and forceps to cut, separate, and grasp a plant shoot. The great advantage offered by the present device is that its design and operation are simpler than would be those of a device based on the manual cutting/separation/grasping procedure. [The present device should not be confused with a prior device developed for partly the same purpose and described in Compliant Gripper for a Robotic Manipulator (NPO-21104), NASA Tech Briefs, Vol. 27, No. 3 (March 2003), page 59.]. The device (see figure) includes a circular tube sharpened at its open (lower) end and mounted on a robotic manipulator at its closed (upper) end. The robotic manipulator simply pushes the sharpened open end of the tube down onto a bed of plants and rotates a few degrees clockwise then counterclockwise about the vertical axis, causing the tube to cut a cylindrical plug of plant material. Exploiting the natural friction between the tube and plug, the tube retains the plug, without need for a gripping mechanism and control. The robotic manipulator then retracts the tube, translates it to a new location over a plant-growth tray, and inserts the tube part way into the growth medium at this location in the tray. A short burst of compressed air is admitted to the upper end of the tube to eject the plug of plant material and drive it into the growth medium. A prototype has been tested and verified to function substantially as intended. It is projected that in the fully developed robotic plant-propagation system, the robot control system would include a machine- vision subsystem that would automatically guide the robotic manipulator in choosing the positions from which to cut plugs of plant material. Planned further development efforts also include more testing and refinement of the design and operation described above.

  7. Collagen nerve guides for surgical repair of brachial plexus birth injury.

    PubMed

    Ashley, William W; Weatherly, Trisha; Park, Tae Sung

    2006-12-01

    Standard brachial plexus repair techniques often involve autologous nerve graft placement and neurotization. However, when performed to treat severe injuries, this procedure can sometimes yield poor results. Moreover, harvesting the autologous graft is time-consuming and exposes the patient to additional surgical risks. To improve surgical outcomes and reduce surgical risks associated with autologous nerve graft retrieval and placement, the authors use collagen matrix tubes (Neurogen) instead of autologous nerve graft material. Between 1991 and 2005, the authors surgically treated 65 infants who had suffered brachial plexus injury at birth. During this time, seven patients were treated using collagen matrix tubes (Neurogen). This study is a retrospective analysis of the initial five patients who were treated using the tubes. Two patients underwent tube placement recently and were excluded from the analysis because of the inadequate follow-up period. Four of the five patients experienced a good recovery (motor scale composite [MSC] > 0.6), and three exhibited an excellent recovery (MSC > 0.75) at 2 years postoperatively. The MSC improved by an average of 69 and 78% at 1 and 2 years, respectively. The movement scores improved to greater than or equal to 50% range of motion in most patients, and the contractures were usually mild or moderate. Follow-up physical and occupational therapy evaluations confirm these patients' functional status. When last seen, four of five of these children could feed and dress themselves. Technically, the use of the collagen matrix tubes was straightforward and efficient, and there were no complications. The outcomes in this small series are encouraging.

  8. Utility of Adjunctive Procedures With Balloon Dilation of the Eustachian Tube.

    PubMed

    Ashry, Yehia; Kawai, Kosuke; Poe, Dennis

    2017-12-01

    To assess the role and effect of concomitant adjunctive procedures when combined with balloon dilation of the Eustachian tube (BDET), including a new technique for treating obstructive disease within the bony Eustachian tube (ET). Retrospective case series. Tertiary medical center. Adults with persistent (≥2 years): 1) OME or non-fixed TM retraction AND type B or C tympanogram OR 2) Consistent symptoms of barochallenge with flights or diving, all despite medical treatment for ≥6 weeks. Balloon dilation of the cartilaginous ET (BDET) was performed under general anesthesia using concomitant myringotomy with or without tube placement if indicated. Adjunctive turbinectomy, adenoidectomy, and/or tympanoplasty were used in selected cases. For suspected disease in the bony ET, an illuminated guidewire was used for probing and clearing the lumen. Outcome measures were tympanogram, otomicroscopy, ET mucosal inflammation score, Valsalva maneuver, and PTA audiometry. 67 ETs (48 patients) underwent BDET: 1) 30/67 balloon w/wo myringotomy, w/wo tube, 2) 20/67 plus adjunctive procedure or 3) 17/67 plus guidewire. Follow-up was ranging from 0.4 to 3.4 years (mean 1.3 year, SD = 0.7). Significant improvement occurred in 79%. There was no significant difference in the failure rate comparing balloon dilation with adjunctive procedures 5/20 (25%) or without adjunctive procedures; 4/30 p  = 0.45 (13%). Failure rate for BDET plus guide wire was 5/17 (29%) and resistance within the bony ET occurred in 8/17 (47%). Balloon dilation of the cartilaginous ET demonstrated significant improvement despite expansion of indications that necessitated the addition of adjunctive procedures. 4.

  9. Comparison of numerical and experimental results of the flow in the U9 Kaplan turbine model

    NASA Astrophysics Data System (ADS)

    Petit, O.; Mulu, B.; Nilsson, H.; Cervantes, M.

    2010-08-01

    The present work compares simulations made using the OpenFOAM CFD code with experimental measurements of the flow in the U9 Kaplan turbine model. Comparisons of the velocity profiles in the spiral casing and in the draft tube are presented. The U9 Kaplan turbine prototype located in Porjus and its model, located in Älvkarleby, Sweden, have curved inlet pipes that lead the flow to the spiral casing. Nowadays, this curved pipe and its effect on the flow in the turbine is not taken into account when numerical simulations are performed at design stage. To study the impact of the inlet pipe curvature on the flow in the turbine, and to get a better overview of the flow of the whole system, measurements were made on the 1:3.1 model of the U9 turbine. Previously published measurements were taken at the inlet of the spiral casing and just before the guide vanes, using the laser Doppler anemometry (LDA) technique. In the draft tube, a number of velocity profiles were measured using the LDA techniques. The present work extends the experimental investigation with a horizontal section at the inlet of the draft tube. The experimental results are used to specify the inlet boundary condition for the numerical simulations in the draft tube, and to validate the computational results in both the spiral casing and the draft tube. The numerical simulations were realized using the standard k-e model and a block-structured hexahedral wall function mesh.

  10. Apparatus and method for detecting leaks in piping

    DOEpatents

    Trapp, Donald J.

    1994-01-01

    A method and device for detecting the location of leaks along a wall or piping system, preferably in double-walled piping. The apparatus comprises a sniffer probe, a rigid cord such as a length of tube attached to the probe on one end and extending out of the piping with the other end, a source of pressurized air and a source of helium. The method comprises guiding the sniffer probe into the inner pipe to its distal end, purging the inner pipe with pressurized air, filling the annulus defined between the inner and outer pipe with helium, and then detecting the presence of helium within the inner pipe with the probe as is pulled back through the inner pipe. The length of the tube at the point where a leak is detected determines the location of the leak in the pipe.

  11. Alternative method for predicting optimal insertion depth of the laryngeal tube in children.

    PubMed

    Kim, J T; Jeon, S Y; Kim, C S; Kim, S D; Kim, H S

    2007-11-01

    Little information is available about the accuracy of the teeth mark on the laryngeal tube (LT) as a guide to correct placement in children. The aim of this crossover study was to evaluate three methods for optimal insertion depth of the size (#) 2 tube in children weighing 12-25 kg. In 24 children, the LT #2 was consecutively inserted by three different methods: (A) until the thick teeth mark on the tube was aligned with the upper incisors, (B) until resistance was felt, and (C) by inserting to a depth, previously measured, of the curved distance between the cricoid cartilage and the upper incisor. In each case, the depth of insertion, the degree of effective ventilation, the presence of leakage, and the fibreoptic view were assessed. Insertion based on the teeth mark led to a shorter insertion depth and a greater incidence of inadequate ventilation compared with the other two methods. There was no difference in the adequacy of ventilation between methods B and C. The vocal cords were more easily identified with methods B (62.5%) and C (75%) than with method A (12.5%). Insertion of the LT #2 aligned with the teeth mark can result in a shallow insertion depth and inadequate ventilation. The measured distance from the cricoid cartilage to the upper incisor offers alternative guidance for correct LT insertion.

  12. Surface current balance and thermoelectric whistler wings at airless astrophysical bodies: Cassini at Rhea

    NASA Astrophysics Data System (ADS)

    Teolis, B. D.; Sillanpää, I.; Waite, J. H.; Khurana, K. K.

    2014-11-01

    Sharp magnetic perturbations found by the Cassini spacecraft at the edge of the Rhea flux tube are consistent with field-aligned flux tube currents. The current system results from the difference of ion and electron gyroradii and the requirement to balance currents on the sharp Rhea surface. Differential-type hybrid codes that solve for ion velocity and magnetic field have an intrinsic difficulty modeling the plasma absorber's sharp surface. We overcome this problem by instead using integral equations to solve for ion and electron currents and obtain agreement with the magnetic perturbations at Rhea's flux tube edge. An analysis of the plasma dispersion relations and Cassini data reveals that field-guided whistler waves initiated by (1) the electron velocity anisotropy in the flux tube and (2) interaction with surface sheath electrostatic waves on topographic scales may facilitate propagation of the current system to large distances from Rhea. Current systems like those at Rhea should occur generally, for plasma absorbers of any size such as spacecraft or planetary bodies, in a wide range of space plasma environments. Motion through the plasma is not essential since the current system is thermodynamic in origin, excited by heat flow into the object. The requirements are a difference of ion and electron gyroradii and a sharp surface, i.e., without a significant thick atmosphere.

  13. Aircraft Crash Survival Design Guide. Volume 4. Aircraft Seats, Restraints, Litters, and Cockpit/Cabin Delethalization

    DTIC Science & Technology

    1989-12-01

    ILLUSTRATIONS (CONTD) 44 Tubular strut wire - bending energy absorber ...... ........... 91 45 Inversion tube concepL with typical force-deformation...expected from a rod-bending sled decelerator and a wire - bending seat load limiter (Refer- ences 35 and 36). Therefore, correcting the calculated...attaching the seat bucket to the rollers, compressive as well as tensile loads can be sustained. Two variations of the wire - bending device have been

  14. Aircraft Crash Survival Design Guide. Volume 4. Aircraft Seats, Restraints. Litters, and Padding

    DTIC Science & Technology

    1980-06-01

    11i 34 Tubular strut wire - bending energy absorber with force-deflection curves ..... . . . . . . . . . . 113 35 Inversion tube concept with...decelera- tor and a wire - bending seat load limiter (References 31 and 32). Therefore, correcting the calculated distance yields 16.25/0.8 - 20.31 in. It...Naval Air Development Center, Warminster, Pennsylvania, October 1969. )- 109 I-. - - ’. Two variations of the wire - bending device have been developed and

  15. Guide Manual of Cooling Methods for Electronic Equipment

    DTIC Science & Technology

    1955-03-31

    CLEVELAND, OHIO BUREAU OF SHIPS tu OfNAVY DEPARTMENT WASHINGTON 25, D. C, ,:o : M ,, ,,,,;,;,,--r t 1oeipii;; n .. , , .M.-- .,., itti,.’( Best Available Copy...Tube Circuits 167 56. Pressure Temperature Relationshio of "Freon" com- 190 pounds 57. Fluorochemical N -h3 Vapor Pressure - Temperature 191 58...Fluorochemical N -43 Temperature vs. Density - 192 Viscosity 59. Fluorochemical 0-75 Vapor Pressure - Temperature 193 60. Fluorochemical 0-75 Temperature vs

  16. Comparison between Two Endotracheal Tube Cuff Inflation Methods; Just-Seal Vs. Stethoscope-Guided.

    PubMed

    Borhazowal, Rishiraj; Harde, Minal; Bhadade, Rakesh; Dave, Sona; Aswar, Swapnil Ganeshrao

    2017-06-01

    The Endotracheal Tube (ETT) cuff performs a critical function of sealing the airway during positive pressure ventilation. There is a narrow range of cuff pressure required to maintain a functionally safe seal without exceeding capillary blood pressure. We aimed to compare Just-Seal (JS) and Stethoscope-Guided (SG) method of ETT cuff inflation with respect to the volume of air required to inflate the cuff, the manometric cuff pressure achieved and also to assess for the occurrence of postoperative sore throat after extubation in both the groups. It was a prospective observational study done in a Tertiary Teaching Public Hospital over a period of 1½ years on 100 patients with 50 each in two groups; JS or SG method of cuff inflation. SPSS Version 17 was used for data analysis. Statistically significant difference (p-value of less than 0.05) was noted between the two methods based on the volume of air injected into the cuff {the mean volume injected in JS was 6.79 ml and in the SG was 4.95 ml with p=5.71E-16 (< 0.05)} and cuff pressure achieved {mean cuff pressure achieved was 38.80 cm H 2 O in the JS and 29.64 cm H 2 O in SG with p=2.29E-14 (< 0.05)}. The incidence of post extubation sore throat was 54% (27 in 50) in the JS group and only 12% (6 in 50) in the SG; p= 0.00000797. ETT cuff inflation guided by a stethoscope is an effective technique for ensuring appropriate cuff pressures thus accomplishing the objective of providing safe and superior quality care of the patient both during and after anaesthesia and reducing the likelihood of even minimal risk complications that may still have legal implications.

  17. Design of an everting balloon to deploy a microendoscope to the fallopian tubes

    NASA Astrophysics Data System (ADS)

    Keenan, Molly; Howard, Caitlin; Tate, Tyler; McGuiness, Ian; Sauer-Budge, Alexis; Black, John; Utzinger, Urs; Barton, Jennifer K.

    2016-02-01

    The 5-year survival rate for ovarian cancer is only 45% largely due to lack of effective screening methods. Current methods include palpation, transvaginal ultrasound, and the CA-125 blood test. Finding disease reliably and at an early stage increase survival to 92%. We have designed and built a 0.7 mm endoscope for the early detection of ovarian cancer. Inserted transvaginally through the working channel of a hysteroscope, the falloposcope creates a minimally invasive procedure for the screening of high risk women. To improve the ease-of-use and safety of falloposcope deployment, we are working to create an everting balloon. Currently, the falloposcope would require a skilled user to operate due to the challenging anatomy of the fallopian tubes - a small opening from the uterus (< 1 mm), tortuous path, and delicate lumenal features. A balloon delivery system would gently open the fallopian tube and guide the falloposcope down the center of lumen. We show balloon design and discuss integration with the falloposcope prototype. We test possible mechanical damage to the tissue due to scraping, puncture, or overstretching. Successful introduction of the everting balloon to simplify falloposcope delivery could expand screening beyond specialized centers to smaller clinical locations.

  18. Applying a structured innovation process to interventional radiology: a single-center experience.

    PubMed

    Sista, Akhilesh K; Hwang, Gloria L; Hovsepian, David M; Sze, Daniel Y; Kuo, William T; Kothary, Nishita; Louie, John D; Yamada, Kei; Hong, Richard; Dhanani, Riaz; Brinton, Todd J; Krummel, Thomas M; Makower, Joshua; Yock, Paul G; Hofmann, Lawrence V

    2012-04-01

    To determine the feasibility and efficacy of applying an established innovation process to an active academic interventional radiology (IR) practice. The Stanford Biodesign Medical Technology Innovation Process was used as the innovation template. Over a 4-month period, seven IR faculty and four IR fellow physicians recorded observations. These observations were converted into need statements. One particular need relating to gastrostomy tubes was diligently screened and was the subject of a single formal brainstorming session. Investigators collected 82 observations, 34 by faculty and 48 by fellows. The categories that generated the most observations were enteral feeding (n = 9, 11%), biopsy (n = 8, 10%), chest tubes (n = 6, 7%), chemoembolization and radioembolization (n = 6, 7%), and biliary interventions (n = 5, 6%). The output from the screening on the gastrostomy tube need was a specification sheet that served as a guidance document for the subsequent brainstorming session. The brainstorming session produced 10 concepts under three separate categories. This formalized innovation process generated numerous observations and ultimately 10 concepts to potentially to solve a significant clinical need, suggesting that a structured process can help guide an IR practice interested in medical innovation. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  19. The defectiveness of measurement data in the inclinometer mesurement in the insertion-type aperture and an introduction about the crrection

    NASA Astrophysics Data System (ADS)

    Homma, H.; Fujisawa, K.; Chiba, S.; Ootsuka, Y.; Higuchi, K.; Suganuma, T.

    2010-12-01

    Since 1975, the insertion type borehole inclinometer has been used to measure an underground lateral deformation in the civil engineering works field in Japan. The borehole inclinometer is used for a lot of landslide investigations as an effective measuring instrument to judge the slide surface position and the rate of slip. On the other hand, it became popular to be able to gather cores at 100% collection rate by the core-pack-tube method having been developed in the drilling survey. As a result, because the grasp accuracy of geological features had improved greatly, it became clear there was a case where the measurement data of the borehole inclinometer did not obviously show the displacement of the ground. As a result,to correct data even if the method of setting up the guide pipe is examined so as not to generate defective data , some engineers where such the realities were understood have been examining it about the correction method. Therefore, there is a case where there is no standards united about the methods of measuring the insertion type borehole inclinometer, and defective data is used still as a result of the observation though the ratio of defective data has decreased. The Pubic Works Research Institute landslide team and three private company companies of Japan did a joint research from these on the generation of defective data between fiscal year 2008 and fiscal year 2009 to prevent it. And, they made the manual that brought the matter to do an appropriate borehole inclinometer (Insertion type borehole inclinometer measurement manual on the landslide ground). In various experiments executed by a joint research, to prevent defective data being generated, it has been understood that the installation of the guide pipe is most important. The following two problems occur if a defective installation of the guide pipe is caused. (1)S shape data in graph (2)Disorder of flat direction of displacement (1) Because filling work at the time of the guide pipe setting is not enough, a gap occurs between a drill hole and a guide pipe. The grout material of the cement system is used standard in Japan. However, the landslide mass flows out easily in general because there are a lot of cracks in addition to low the groundwater level. Therefore we work on filling with paccar, and it is necessary to let a guide pipe and the ground. (2)The direction of the displacement that data shows is different from the direction of the movement of the actual ground. In this data, the product of the guide pipe twists, and both of the twist when setting it up are causes of generation. However, it is almost impossible to prevent this. Therefore, the twist is corrected measuring the azimuth of the guide tube with a simple type borehole camera. The insertion type clinometer in the aperture is a measure used in many landslide, but a guide pipe and revision of certain setting of the ground and the torsion of the guide pipe are necessary to get right data. And, this manual may be useful internationally.

  20. Liquid level sensing device

    DOEpatents

    Tokarz, Richard D.

    1983-01-01

    A liquid level sensing device comprising a load cell supporting a column or stack of segments freely resting on one another. The density of each element is substantially identical to that of the surrounding liquid. The elements are freely guided within a surrounding tube. As each element is exposed above the liquid level, its weight will be impressed through the column to the load cell, thereby providing a signal at the load cell directly proportional to the liquid level elevation.

  1. Flexible ion conduit for use under rarefied atmospheric conditions

    NASA Astrophysics Data System (ADS)

    Hars, Gyorgy; Meuzelaar, Henk LC.

    1997-09-01

    A tubular ion conduit has been constructed, which transports ions by convection by means of a carrier gas. Typical inlet pressures are in the 10-100 Torr range, with outlet pressures as low as 10-3 Torr. The 20-30 cm, 1-2-mm-i.d., capillary tube, made of an electrically insulating material, is surrounded by a specifically configured pair of helical electrodes ("helical dipole"), which are supplied with symmetrical voltages in the tens of volt amplitude and in 1 MHz frequency range. The vibrational average force field generated reduces the tendency of ions to hit the inner wall of the tube. This way ions can be transported with minimal loss. Previously, known ion guides are operated under molecular flow (high vacuum) conditions only, as opposed to the method described here, where the carrier gas enters under viscous flow conditions and exits as molecular flow. In addition, existing ion guides are stiff in contrast to the flexible construction described here, which can be easily and inexpensively manufactured. The ion conduit is expected to have important applications in connecting ambient or near-ambient pressure electrospray ionization or atmospheric pressure ionization type ion sources to mass spectrometers, while reducing pumping requirements, e.g., field portable equipment. Furthermore, the device may provide a means for connecting electron multiplier detectors to near ambient pressure analyzers such as ion mobility spectrometers.

  2. Global electrostatic potential structures of merging flux tubes in TS-U torus plasma merging experiment

    NASA Astrophysics Data System (ADS)

    Sawada, Asuka; Hatano, Hironori; Akimitsu, Moe; Cao, Qinghong; Yamasaki, Kotaro; Tanabe, Hiroshi; Ono, Yasushi; TS-Group Team

    2017-10-01

    We have been investigating 2D potential profile of global merging tokamaks to solve high-power heating of magnetic reconnection in TS-3 and TS-3U (ST, FRC:R =0.2m, 1985-, 2017-) and TS-4 (ST, FRC:R =0.5m, 2000-), UTST (ST:R =0.45m, 2008-) and MAST (ST:R = 0.9m, 2000-) devices. These experiments made clear that the electrostatic potential well is formed not only in the downstream area of magnetic reconnection but also in the whole common (reconnected) flux area of two merging flux tubes: tokamak plasmas. This fact suggests that the ion acceleration/heating occurs in much wider region than the reconnection downstream. We studied how the potential structure depends on key reconnection parameters:guide toroidal field and plasma collisionality. We found the polarity of the guide toroidal field determines those of potential hills and wells, indicating their formation is affected by the Hall effect. The peak value of the electrostatic potential well decreased with gas pressure increasing, suggesting plasma collisionality suppresses the Hall effect. The relationship between the electrostatic potential structure and anomalous ion heating is being studied as a possible cause for the high-power heating of fast magnetic reconnection. This work was supported by JSPS KAKENHI Grant Numbers 15H05750, 15K14279 and 17H04863.

  3. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study.

    PubMed

    Michalek, P; Donaldson, W; Graham, C; Hinds, J D

    2010-01-01

    Insertion of a supraglottic airway and tracheal intubation through it may be indicated in resuscitation scenarios where conventional laryngoscopy fails. Various supraglottic devices have been used as conduits for tracheal intubation, including the intubating laryngeal mask airway (ILMA), the Ctrach laryngeal mask and the I-gel supraglottic airway. A prospective study with 25 participants evaluated the success rate of blind intubation (using a gum-elastic bougie, an Aintree intubating catheter (AIC) and designated tracheal tube) and fibrescope-guided tracheal intubation (through the intubating laryngeal mask airway and the I-gel supraglottic airway) on three different airway manikins. Twenty-five anaesthetists performed three intubations with each method on each of three manikins. The success rate of the fibrescope-guided technique was significantly higher than blind attempts (P<0.0001) with both devices. For fibreoptic techniques, there was no difference found between the ILMA and I-gel (P>0.05). All blind techniques were significantly more successful in the ILMA group compared to the I-gel (P<0.0001 for bougie, Aintree catheter and tracheal tube, respectively). The results of this study show that, in manikins, fibreoptic intubation through both ILMA and I-gel is a highly successful technique. Blind intubation through the I-gel showed a low success rate and should not be attempted. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  4. The Valsalva manoeuvre versus tourniquet for venipuncture.

    PubMed

    Villa, Gianluca; Chelazzi, Cosimo; Giua, Rosa; Lavacchini, Laura; Tofani, Lorenzo; Zagli, Giovanni; Barbani, Francesco; De Gaudio, A Raffaele; Romagnoli, Stefano; Pinelli, Fulvio

    2018-03-01

    During ultrasound-guided cannulation, venous filling is required for venipuncture. Tourniquet with an elastic tube at the axilla is the most common method to induce venous stasis for cannulation of the deep veins of the arm. Although effective, this method might be associated with short- and long-term complications. Valsalva manoeuvre has been used to produce venous filling in other extrathoracic veins. The aim of this observational study is to demonstrate the effect of Valsalva manoeuvre in respect of the elastic tourniquet on venous distention during echography-guided cannulation of the deep veins of the arm. Sixty-nine patients scheduled for cannulation of basilic or brachial vein were prospectively observed. Vein diameters were recorded at rest and after 10 s of Valsalva or tourniquet placement. The mean difference between basilic vein diameters during tourniquet and Valsalva manoeuvre was 0.006 mm (95% confidence interval = -inf, 0.09) with a standard deviation of 0.5 mm (95% confidence interval = 0.5, 0.7; p > 0.01). The mean difference between brachial vein diameters during tourniquet and Valsalva manoeuvre was 0.04 mm (95% confidence interval = -0.23, 0.15) with a standard deviation of 0.8 mm (95% confidence interval = 0.7, 0.9; p > 0.01). This increase in cross-sectional basilic and brachial vein diameters was not different to that obtained with the elastic tube tourniquet.

  5. Nuclear reactor neutron shielding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Speaker, Daniel P; Neeley, Gary W; Inman, James B

    A nuclear reactor includes a reactor pressure vessel and a nuclear reactor core comprising fissile material disposed in a lower portion of the reactor pressure vessel. The lower portion of the reactor pressure vessel is disposed in a reactor cavity. An annular neutron stop is located at an elevation above the uppermost elevation of the nuclear reactor core. The annular neutron stop comprises neutron absorbing material filling an annular gap between the reactor pressure vessel and the wall of the reactor cavity. The annular neutron stop may comprise an outer neutron stop ring attached to the wall of the reactormore » cavity, and an inner neutron stop ring attached to the reactor pressure vessel. An excore instrument guide tube penetrates through the annular neutron stop, and a neutron plug comprising neutron absorbing material is disposed in the tube at the penetration through the neutron stop.« less

  6. Audit of Endotracheal Tube Suction in a Pediatric Intensive Care Unit.

    PubMed

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2017-02-01

    We report outcomes of a clinical audit examining criteria used in clinical practice to rationalize endotracheal tube (ETT) suction, and the extent these matched criteria in the Endotracheal Suction Assessment Tool(ESAT)©. A retrospective audit of patient notes ( N = 292) and analyses of criteria documented by pediatric intensive care nurses to rationalize ETT suction were undertaken. The median number of documented respiratory and ventilation status criteria per ETT suction event that matched the ESAT© criteria was 2 [Interquartile Range (IQR) 1-6]. All criteria listed within the ESAT© were documented within the reviewed notes. A direct link was established between criteria used for current clinical practice of ETT suction and the ESAT©. The ESAT©, therefore, reflects documented clinical decision making and could be used as both a clinical and educational guide for inexperienced pediatric critical care nurses. Modification to the ESAT © requires "preparation for extubation" to be added.

  7. Apparatus and method for detecting leaks in piping

    DOEpatents

    Trapp, D.J.

    1994-12-27

    A method and device are disclosed for detecting the location of leaks along a wall or piping system, preferably in double-walled piping. The apparatus comprises a sniffer probe, a rigid cord such as a length of tube attached to the probe on one end and extending out of the piping with the other end, a source of pressurized air and a source of helium. The method comprises guiding the sniffer probe into the inner pipe to its distal end, purging the inner pipe with pressurized air, filling the annulus defined between the inner and outer pipe with helium, and then detecting the presence of helium within the inner pipe with the probe as is pulled back through the inner pipe. The length of the tube at the point where a leak is detected determines the location of the leak in the pipe. 2 figures.

  8. Further Development of Scaffolds for Regeneration of Nerves

    NASA Technical Reports Server (NTRS)

    Sakamoto, Jeffrey; Tuszynski, Mark

    2009-01-01

    Progress has been made in continuing research on scaffolds for the guided growth of nerves to replace damaged ones. The scaffolds contain pores that are approximately cylindrical and parallel, with nearly uniform widths ranging from tens to hundreds of microns. At the earlier stage of development, experimental scaffolds had been made from agarose hydrogel. Such a scaffold was made in a multistep process in which poly(methyl methacrylate) [PMMA] fibers were used as templates for the pores. The process included placement of a bundle of the PMMA fibers in a tube, filling the interstices in the tube with a hot agarose solution, cooling to turn the solution into a gel, and then immersion in acetone to dissolve the PMMA fibers. The scaffolds were typically limited to about 25 pores per scaffold, square cross sections of no more than about 1.5 by 1.5 mm, and lengths of no more than about 2 mm.

  9. Reconfigurable origami-inspired acoustic waveguides

    PubMed Central

    Babaee, Sahab; Overvelde, Johannes T. B.; Chen, Elizabeth R.; Tournat, Vincent; Bertoldi, Katia

    2016-01-01

    We combine numerical simulations and experiments to design a new class of reconfigurable waveguides based on three-dimensional origami-inspired metamaterials. Our strategy builds on the fact that the rigid plates and hinges forming these structures define networks of tubes that can be easily reconfigured. As such, they provide an ideal platform to actively control and redirect the propagation of sound. We design reconfigurable systems that, depending on the externally applied deformation, can act as networks of waveguides oriented along one, two, or three preferential directions. Moreover, we demonstrate that the capability of the structure to guide and radiate acoustic energy along predefined directions can be easily switched on and off, as the networks of tubes are reversibly formed and disrupted. The proposed designs expand the ability of existing acoustic metamaterials and exploit complex waveguiding to enhance control over propagation and radiation of acoustic energy, opening avenues for the design of a new class of tunable acoustic functional systems. PMID:28138527

  10. FRACTURE STRENGTH AND TIME DEPENDENT PROPERTIES OF 0/90 AND ±55-BRAIDED WEAVE SiC/SiC TYPE-S FIBER COMPOSITES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henager, Charles H.

    PNNL has performed mechanical property tests on two types of Hi-Nicalon Type-S fiber SiC/SiC composites for the general purpose of evaluating such composites for control rod guide tube applications in the NGNP high-temperature gas-cooled reactor design. The mechanical testing consisted of 4-point bend strength, 4-point single-edge notched bend fracture toughness, and 4-point bend slow crack growth testing on both composites from ambient to 1600°C (1873K). The two composite materials that were tested included a ±55°-braided-weave composite with Type-S fibers inclined at 55° to the principal composite axes to simulate a braided tube architecture and a Type-S 0/90 satin-weave composite asmore » a reference material.« less

  11. Construction Simulation Analysis of 60m-span Concrete Filled Steel Tube arch bridge

    NASA Astrophysics Data System (ADS)

    Shi, Jing Xian; Ding, Qing Hua

    2018-06-01

    The construction process of the CFST arch bridge is complicated. The construction process not only affects the structural stress in the installation, but also determines the form a bridge and internal force of the bridge. In this paper, a 60m span concrete filled steel tube tied arch bridge is taken as the background, and a three-dimensional finite element simulation model is established by using the MIDAS/Civil bridge structure analysis software. The elevation of the main arch ring, the beam stress, the forces in hanger rods and the modal frequency of the main arch during the construction stage are calculated, and the construction process is simulated and analyzed. Effectively and reasonably guide the construction and ensure that the line and force conditions of the completed bridge meet the design requirements and provides a reliable technical guarantee for the safe construction of the bridge.

  12. Patient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT

    PubMed Central

    Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2011-01-01

    Purpose: To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. Materials and Methods: The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0–16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDIvol) or dose–length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Results: Organ dose normalized by tube current–time product or CTDIvol decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current–time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current–time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (<10% variation). Conclusion: The correlations of dose and risk with patient size and age can be used to estimate patient-specific dose and risk. They can further guide the design and optimization of pediatric chest CT protocols. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101900/-/DC1 PMID:21467251

  13. Patient-specific radiation dose and cancer risk for pediatric chest CT.

    PubMed

    Li, Xiang; Samei, Ehsan; Segars, W Paul; Sturgeon, Gregory M; Colsher, James G; Frush, Donald P

    2011-06-01

    To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0-16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Organ dose normalized by tube current-time product or CTDI(vol) decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current-time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current-time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (<10% variation). The correlations of dose and risk with patient size and age can be used to estimate patient-specific dose and risk. They can further guide the design and optimization of pediatric chest CT protocols. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101900/-/DC1. RSNA, 2011

  14. YouTube provides irrelevant information for the diagnosis and treatment of hip arthritis.

    PubMed

    Koller, Ulrich; Waldstein, Wenzel; Schatz, Klaus-Dieter; Windhager, Reinhard

    2016-10-01

    YouTube is increasingly becoming a key source for people to satisfy the need for additional information concerning their medical condition. This study analyses the completeness of accurate information found on YouTube pertaining to hip arthritis. The present study analyzed 133 YouTube videos using the search terms: hip arthritis, hip arthritis symptoms, hip arthritis diagnosis, hip arthritis treatment and hip replacement. Two quality assessment checklists with a scale of 0 to 12 points were developed to evaluate available video content for the diagnosis and the treatment of hip arthritis. Videos were grouped into poor quality (grade 0-3), moderate quality (grade 4-7) and excellent quality (grade 8-12), respectively. Three independent observers assessed all videos using the new grading system and independently scored all videos. Discrepancies regarding the categories were clarified by consensus discussion. For intra-observer reliabilities, grading was performed at two occasions separated by four weeks. Eighty-four percent (n = 112) had a poor diagnostic information quality, 14% (n = 19) a moderate quality and only 2% (n = 2) an excellent quality, respectively. In 86% (n = 114), videos provided poor treatment information quality. Eleven percent (n = 15) of videos had a moderate quality and only 3% (n = 4) an excellent quality, respectively. The present study demonstrates that YouTube is a poor source for accurate information pertaining to the diagnosis and treatment of hip arthritis. These finding are of high relevance for clinicians as videos are going to become the primary source of information for patients. Therefore, high quality educational videos are needed to further guide patients on the way from the diagnosis of hip arthritis to its proper treatment.

  15. Social media and the intrauterine device: a YouTube content analysis.

    PubMed

    Nguyen, Brian T; Allen, Allison J

    2018-01-01

    YouTube's online archive of video testimonials related to health information are more commonly viewed than those developed by clinicians and professional groups, suggesting the importance of the patient experience to viewers. We specifically sought to examine the accuracy of information on, and projected acceptability of, the intrauterine device (IUD) from these YouTube testimonials. We searched YouTube for videos about individual uploaders' IUD experiences, using the search terms 'intrauterine device', 'IUD', 'Mirena' and 'Paragard'. Given interest in user testimonials, we excluded professional and instructional videos belonging to commercial or non-profit entities. Two reviewers independently analysed the videos using a structured guide, with attention to inaccurate information. Of 86 identified videos, four videos featured clinicians and were excluded; 62 met inclusion criteria. Interrater agreement on IUD portrayal was good (K=0.73). Young (mean age 25, range 19-38, years), white (75%), nulliparous (61%) women primarily uploaded content. Most described placement of the LNG-IUS (65%), were posted within 1 month of insertion (45%), and mentioned side effects (66%) - bleeding, pain, and partner sensation of the strings. About one-third of videos contained inaccurate information (34%) and were thought to project an overall negative experience (30%). Videos portraying IUDs negatively were associated with inaccurate information and/or mention of side effects. While one-third of IUD user testimonials on YouTube contained inaccurate information, the majority of IUD experiences were perceived by our study viewers to be positive. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Utility of Adjunctive Procedures With Balloon Dilation of the Eustachian Tube

    PubMed Central

    Ashry, Yehia; Kawai, Kosuke

    2017-01-01

    Objective To assess the role and effect of concomitant adjunctive procedures when combined with balloon dilation of the Eustachian tube (BDET), including a new technique for treating obstructive disease within the bony Eustachian tube (ET). Study Design Retrospective case series. Setting Tertiary medical center. Subjects Adults with persistent (≥2 years): 1) OME or non‐fixed TM retraction AND type B or C tympanogram OR 2) Consistent symptoms of barochallenge with flights or diving, all despite medical treatment for ≥6 weeks. Methods Balloon dilation of the cartilaginous ET (BDET) was performed under general anesthesia using concomitant myringotomy with or without tube placement if indicated. Adjunctive turbinectomy, adenoidectomy, and/or tympanoplasty were used in selected cases. For suspected disease in the bony ET, an illuminated guidewire was used for probing and clearing the lumen. Outcome measures were tympanogram, otomicroscopy, ET mucosal inflammation score, Valsalva maneuver, and PTA audiometry. Results 67 ETs (48 patients) underwent BDET: 1) 30/67 balloon w/wo myringotomy, w/wo tube, 2) 20/67 plus adjunctive procedure or 3) 17/67 plus guidewire. Follow‐up was ranging from 0.4 to 3.4 years (mean 1.3 year, SD = 0.7). Significant improvement occurred in 79%. There was no significant difference in the failure rate comparing balloon dilation with adjunctive procedures 5/20 (25%) or without adjunctive procedures; 4/30 p = 0.45 (13%). Failure rate for BDET plus guide wire was 5/17 (29%) and resistance within the bony ET occurred in 8/17 (47%). Conclusion Balloon dilation of the cartilaginous ET demonstrated significant improvement despite expansion of indications that necessitated the addition of adjunctive procedures. Level of Evidence 4 PMID:29299505

  17. Interventions for maintaining nasogastric feeding after stroke: An integrative review of effectiveness and acceptability.

    PubMed

    Mahoney, Catherine; Veitch, Linda

    2018-02-01

    To investigate the effectiveness and acceptability of interventions for maintaining nasogastric tubes in adult stroke patients. Internationally, incidence of cerebral vascular disease continues to increase and stroke is the largest cause of complex disability in adults. Dysphagia is common following a stroke which necessitates feeding via a nasogastric tube. Nasogastric tubes are not well tolerated by stroke patients and may be frequently dislodged. Hence, interventions such as tape, the nasal bridle/loop or hand mittens may be used to maintain nasogastric tube position. However, evidence around the effectiveness and acceptability of these interventions has not been reviewed and synthesised. Integrative literature review. Database searches in MEDLINE, PubMed, CINAHL, Scopus, Cochrane and EMBASE; manual reference list searches. Seven studies met the eligibility criteria and were included in the review. Evidence for the effectiveness of nasal bridle/loop and hand mittens to maintain nasogastric tube position in patients after a stroke is spare and methodologically poor, and especially limited around hand mittens use. There is insufficient evidence about the acceptability of both nasal bridle/loop and hand mittens among stroke patients. Current clinical practice is underpinned by assumptions around the acceptability of nasal bridle/loop and hand mittens to secure nasogastric tubes. This results in reliance on consensual judgement between professional, patients and their families to guide their use among individuals with dysphagia after stroke. Further research is required to assess the effectiveness of hand mittens and acceptability of both nasal bridle/loop and hand mittens among stroke patients to inform guideline development. Given the lack of evidence on the acceptability of hand mittens and nasal bridle/loop among stroke patients to inform evidence-based guidelines and protocols, healthcare professionals should reach consensus on their use by exercising clinical judgement and through consultation with patients (if possible) and their families. © 2017 John Wiley & Sons Ltd.

  18. A tetrahedron beam computed tomography benchtop system with a multiple pixel field emission x-ray tube

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Xiaochao; Kim, Joshua; Laganis, Philip

    2011-10-15

    Purpose: To demonstrate the feasibility of Tetrahedron Beam Computed Tomography (TBCT) using a carbon nanotube (CNT) multiple pixel field emission x-ray (MPFEX) tube. Methods: A multiple pixel x-ray source facilitates the creation of novel x-ray imaging modalities. In a previous publication, the authors proposed a Tetrahedron Beam Computed Tomography (TBCT) imaging system which comprises a linear source array and a linear detector array that are orthogonal to each other. TBCT is expected to reduce scatter compared with Cone Beam Computed Tomography (CBCT) and to have better detector performance. Therefore, it may produce improved image quality for image guided radiotherapy. Inmore » this study, a TBCT benchtop system has been developed with an MPFEX tube. The tube has 75 CNT cold cathodes, which generate 75 x-ray focal spots on an elongated anode, and has 4 mm pixel spacing. An in-house-developed, 5-row CT detector array using silicon photodiodes and CdWO{sub 4} scintillators was employed in the system. Hardware and software were developed for tube control and detector data acquisition. The raw data were preprocessed for beam hardening and detector response linearity and were reconstructed with an FDK-based image reconstruction algorithm. Results: The focal spots were measured at about 1 x 2 mm{sup 2} using a star phantom. Each cathode generates around 3 mA cathode current with 2190 V gate voltage. The benchtop system is able to perform TBCT scans with a prolonged scanning time. Images of a commercial CT phantom were successfully acquired. Conclusions: A prototype system was developed, and preliminary phantom images were successfully acquired. MPFEX is a promising x-ray source for TBCT. Further improvement of tube output is needed in order for it to be used in clinical TBCT systems.« less

  19. A deflectable guiding catheter for real-time MRI-guided interventions.

    PubMed

    Bell, Jamie A; Saikus, Christina E; Ratnayaka, Kanishka; Wu, Vincent; Sonmez, Merdim; Faranesh, Anthony Z; Colyer, Jessica H; Lederman, Robert J; Kocaturk, Ozgur

    2012-04-01

    To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures. The catheter shaft incorporated Kevlar braiding. A 180° deflection was attained with a 5-cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine. Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo. Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057" lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements. Copyright © 2011 Wiley Periodicals, Inc.

  20. SCC analysis of Alloy 600 tubes from a retired steam generator

    NASA Astrophysics Data System (ADS)

    Hwang, Seong Sik; Kim, Hong Pyo

    2013-09-01

    Steam generators (SG) equipped with Alloy 600 tubes of a Korean nuclear power plants were replaced with a new one having Alloy 690 tubes in 1998 after 20 years of operation. To set up a guide line for an examination of the other SG tubes, a metallographic examination of the defected tubes was carried out. A destructive analysis on 71 tubes was addressed, and a relation among the stress corrosion crack (SCC) defect location, defect depth, and location of the sludge pile was obtained. Tubes extracted from the retired SG were transferred to a hot laboratory. Detailed nondestructive analysis examinations were taken again at the laboratory, and the tubes were then destructively examined. The types and sizes of the cracks were characterized. The location and depth of the SCC were evaluated in terms of the location and height of the sludge. Most axial cracks were in the sludge pile, whereas the circumferential ones were around the top of the tube sheet (TTS) or below the TTS. Average defect depth of the axial cracks was deeper than that of the circumferential ones. Axial cracks at tube support plate (TSP) seem to be related with corrosion/sludge in crevice like at the TTS region. Circumferential cracks at TSP seem to be caused by tube denting at the upper part of the TSP. Tubes not having clear ECT signals for quantifying an ECT data-base. Tubes having no ECT signal. Tubes with a large ECT signal. Tubes with various types and sizes of flaws (primary water stress corrosion cracking (PWSCC), outside diameter stress corrosion cracking (ODSCC), Pit). Tubes with distinct PWSCC or ODSCC. Tubes were extracted from the RSG based on the field ECT with the criteria, and transferred to a hot laboratory at the Korea Atomic Energy Research Institute (KAERI) for destructive examination. A comprehensive ECT inspection was performed again at the hot laboratory to confirm the location of the cracks obtained from a field inspection. These exact locations of the defects were marked on the tube specimens for subsequent destructive examinations.Metallography on a tube section was examined by standard metallographic techniques. The mounted specimens were ground and polished. For a chemical activation of the polished surface, the samples were soaked in hydrochloric acid for 20 s then followed by cleaning in methanol. Chemical etching in a bromine etchant (98% Methanol + 2% Bromine) was applied for 3 to 4 s in an ultrasound cleaner.Destructive examinations were carried out using the procedures in accordance with the Electric Power Research Institute (EPRI) tube examination guidelines [2]. The types of defects were characterized and their sizes were measured using a high magnification contact camera and a scanning electron microscope (SEM). The surface deposit compositions on the outer diameter of the tubes were also analyzed using energy dispersive X-ray spectroscopy (EDS). The relation among the SCC defect location, defect depth, and sludge height was explored. Denting, pitting, PWSCC and ODSCC were observed on the RSG tubes as time went on. The analyzed Alloy 600 tube showed a typical LTMA microstructure, and the severe SCC of the RSG was attributed to the microstructure and slightly alkaline crevice environment in some respects. Most axial cracks were observed inside the sludge pile up region, which suggests that sludge may have a role in accelerating the growth of the axial cracks. No correlation was seen in the circumferential cracks and sludge pile, and dents in the tube sheet and phosphate chemistry might cause OD circumferential cracks at the TTS region. The average depth of the axial cracks was higher than that of the circumferential cracks. Axial ID cracks 4 mm long or over at the TTS showed 90%-100% tube wall penetration. On the contrary, the length of the axial OD cracks was not closely related with the depth OD axial cracks around the TSP appeared to be much shallower than those of the TTS region. This implies that the same length of TSP region cracks may have higher structural safety than that of cracks of the TTS region.

  1. Medical X-ray sources now and for the future

    NASA Astrophysics Data System (ADS)

    Behling, Rolf

    2017-11-01

    This paper focuses on the use of X-rays in their largest field of application: medical diagnostic imaging and image-guided therapy. For this purpose, vacuum electronics in the form of X-ray tubes as the source of bremsstrahlung (braking radiation) have been the number one choice for X-ray production in the range of photon energies between about 16 keV for mammography and 150 keV for general radiography. Soft tissue on one end and bony structures on the other are sufficiently transparent and the contrast delivered by difference of absorption is sufficiently high for this spectral range. The dominance of X-ray tubes holds even more than 120 years after Conrad Roentgen's discovery of the bremsstrahlung mechanism. What are the specifics of current X-ray tubes and their medical diagnostic applications? How may the next available technology at or beyond the horizon look like? Can we hope for substantial game changers? Will flat panel sources, less expensive X-ray "LED's", compact X-ray Lasers, compact synchrotrons or equivalent X-ray sources appear in medical diagnostic imaging soon? After discussing the various modalities of imaging systems and their sources of radiation, this overview will briefly touch on the physics of bremsstrahlung generation, key characteristics of X-ray tubes, and material boundary conditions, which restrict performance. It will discuss the deficits of the bremsstrahlung technology and try to sketch future alternatives and their prospects of implementation in medical diagnostics.

  2. On the development of co-axial miniature pulse tube coolers for space applications

    NASA Astrophysics Data System (ADS)

    Zhou, Y.; Liang, J. T.; Zhu, W. Q.; Cai, J. H.; Ju, Y. L.

    2002-05-01

    Cryocoolers for cooling infrared sensors in space applications require high reliability, long lifetime, low power and minimum weight. In this paper we report work on a miniature pulse tube cooler specifically designed for such applications. A series of engineering model co-axial miniature pulse tube coolers with a flexure bearing linear compressor of 1 cc swept volume have been designed and fabricated in our laboratory. A theoretical model is established based on the analyses of thermodynamic and hydrodynamic behaviors of oscillatory flows in regenerator, for performance prediction, optimization and as a rough guide in the early stages of system design. An experimental apparatus, including a hot wire anemometer, has been set up to study the flow resistance of regenerators under oscillatory flow conditions. The co-axial, multi-bypass, and symmetric nozzle structure has been used in the coolers. We will present here the performance of two sizes of coolers with 9 mm and 8 mm diameter of cold fingers. The 9 mm cooler currently provides 500 mW net cooling power at 80 K with input power of 47 W, and the 8 mm cooler, provides 450 mW at 80 K with 51 W input power with a 65% efficient compressor. The cold fingers of our co-axial pulse tube coolers have the similar size of miniature Stirling coolers and are the only one that could meet the geometry specifications of the Standard Advance Dewar Assembly (SADA) for thermal imaging systems in most military applications.

  3. Volume measurement of cryogenic deuterium pellets by Bayesian analysis of single shadowgraphy images

    NASA Astrophysics Data System (ADS)

    Szepesi, T.; Kálvin, S.; Kocsis, G.; Lang, P. T.; Wittmann, C.

    2008-03-01

    In situ commissioning of the Blower-gun injector for launching cryogenic deuterium pellets at ASDEX Upgrade tokamak was performed. This injector is designed for high repetitive launch of small pellets for edge localised modes pacing experiments. During the investigation the final injection geometry was simulated with pellets passing to the torus through a 5.5m long guiding tube. For investigation of pellet quality at launch and after tube passage laser flash camera shadowgraphy diagnostic units before and after the tube were installed. As indicator of pellet quality we adopted the pellet mass represented by the volume of the main remaining pellet fragment. Since only two-dimensional (2D) shadow images were obtained, a reconstruction of the full three-dimensional pellet body had to be performed. For this the image was first converted into a 1-bit version prescribing an exact 2D contour. From this contour the expected value of the volume was calculated by Bayesian analysis taking into account the likely cylindrical shape of the pellet. Under appropriate injection conditions sound pellets with more than half of their nominal mass are detected after acceleration; the passage causes in average an additional loss of about 40% to the launched mass. Analyzing pellets arriving at tube exit allowed for deriving the injector's optimized operational conditions. For these more than 90% of the pellets were arriving with sound quality when operating in the frequency range 5-50Hz.

  4. TickBot: a novel robotic device for controlling tick populations in the natural environment.

    PubMed

    Gaff, Holly D; White, Alexis; Leas, Kyle; Kelman, Pamela; Squire, James C; Livingston, David L; Sullivan, Gerald A; Baker, Elizabeth W; Sonenshine, Daniel E

    2015-03-01

    A semi-autonomous 4-wheeled robot (TickBot) was fitted with a denim cloth treated with an acaricide (permethrin™) and tested for its ability to control ticks in a tick-infested natural environment in Portsmouth, Virginia. The robot's sensors detect a magnetic field signal from a guide wire encased in 80m polyethylene tubing, enabling the robot to follow the trails, open areas and other terrain where the tubing was located. To attract ticks to the treated area, CO2 was distributed through the same tubing, fitted with evenly spaced pores and flow control valves, which permitted uniform CO2 distribution. Tests were done to determine the optimum frequency for TickBot to traverse the wire-guided treatment site as well as the duration of operation that could be accomplished on a single battery charge. Prior to treatment, dragging was done to determine the natural abundance of ticks in the test site. Controls were done without CO2 and without permethrin. TickBot proved highly effective in reducing the overall tick densities to nearly zero with the treatment that included both carbon dioxide pretreatment and the permethrin treated cloth. Following a 60min traverse of the treatment areas, adult tick numbers, almost entirely Amblyomma americanum, was reduced to zero within 1h and remained at or near zero for 24h. Treatments without CO2 also showed reduction of ticks to near zero within 1h, but the populations were no different than the control sections at 4h. This study demonstrates the efficacy of TickBot as a tick control device to significantly reduce the risk of tick bites and disease transmission to humans and companion animals visiting a previously tick-infested natural environment. Continued deployment of TickBot for additional days or weeks can assure a relatively tick-safe environment for enjoyment by the public. Copyright © 2014 Elsevier GmbH. All rights reserved.

  5. The intubating laryngeal mask. II: A preliminary clinical report of a new means of intubating the trachea.

    PubMed

    Brain, A I; Verghese, C; Addy, E V; Kapila, A; Brimacombe, J

    1997-12-01

    We have assessed the efficacy of a new laryngeal mask prototype, the intubating laryngeal mask airway (ILMA), as a ventilatory device and blind intubation guide. The ILMA consists of an anatomically curved, short, wide bore, stainless steel tube sheathed in silicone which is bonded to a laryngeal mask and a guiding handle. It has a single moveable aperture bar, a guiding ramp and can accommodate an 8 mm tracheal tube (TT). After induction of anaesthesia with propofol 2.5 mg kg-1 and fentanyl 2.5 micrograms kg-1, the device was inserted successfully at the first attempt in all 150 (100%) patients and adequate ventilation achieved in all, with minor adjustments required in four patients. Placement did not require movement of the head and neck or insertion of the fingers in the patient's mouth. Blind tracheal intubation using a straight silicone cuffed TT was attempted after administration of atracurium 0.5 mg kg-1. If resistance was felt during intubation, a sequence of adjusting manoeuvres was used based on the depth at which resistance occurred. Tracheal intubation was possible in 149 of 150 (99.3%) patients. In 75 (50%) patients no resistance was encountered and the trachea was intubated at the first attempt, 28 (19%) patients required one adjusting manoeuvre and 46 (31%) patients required 2-4 adjusting manoeuvres before intubation was successful. There were 13 patients with potential or known airway problems. The lungs of all of these patients were ventilated easily and the trachea intubated using the ILMA. In 10 of 13 (77%) of these patients, no resistance was encountered and the trachea was intubated at the first attempt; three of 13 (23%) patients required one adjusting manoeuvre. Tracheal intubation required significantly fewer adjusting manoeuvres in patients with a predicted or known difficult airway (P < 0.05). We conclude that the ILMA appeared on initial assessment to be an effective ventilatory device and intubation guide for routine and difficult airway patients not at risk of gastric aspiration.

  6. A Prospective Observational Study of Technical Difficulty With GlideScope-Guided Tracheal Intubation in Children.

    PubMed

    Zhang, Bin; Gurnaney, Harshad G; Stricker, Paul A; Galvez, Jorge A; Isserman, Rebecca S; Fiadjoe, John E

    2018-05-09

    The GlideScope Cobalt is one of the most commonly used videolaryngoscopes in pediatric anesthesia. Although visualization of the airway may be superior to direct laryngoscopy, users need to learn a new indirect way to insert the tracheal tube. Learning this indirect approach requires focused practice and instruction. Identifying the specific points during tube placement, during which clinicians struggle, would help with targeted education. We conducted this prospective observational study to determine the incidence and location of technical difficulties using the GlideScope, the success rates of various corrective maneuvers used, and the impact of technical difficulty on success rate. We conducted this observational study at our quaternary pediatric hospital between February 2014 and August 2014. We observed 200 GlideScope-guided intubations and documented key intubation-related outcomes. Inclusion criteria for patients were <6 years of age and elective surgery requiring endotracheal intubation. We documented the number of advancement maneuvers required to intubate the trachea, the location where technical difficulty occurred, the types of maneuvers used to address difficulties, and the tracheal intubation success rate. We used a bias-corrected bootstrapping method with 300 replicates to determine the 95% confidence interval (CI) around the rate of difficulty with an intubation attempt. After excluding attempts by inexperienced clinicians, there were 225 attempts in 187 patients, 58% (131 of 225; bootstrap CI, 51.6%-64.6%]) of the attempts had technical difficulties. Technical difficulty was most likely to occur when inserting the tracheal tube between the plane of the arytenoid cartilages to just beyond the vocal cords: "zone 3." Clockwise rotation of the tube was the most common successful corrective maneuver in zone 3. The overall tracheal intubation success rate was 98% (CI, 95%-99%); however, the first attempt success rate was only 80% (CI, 74%-86%). Patients with technical difficulty had more attempts (median [interquartile range], 2 [1-3] than those without technical difficulty median (interquartile range, 1 [1-1; P value <.01]). A variety of clinicians experience technical difficulties with the GlideScope Cobalt videolaryngoscope in children. These difficulties result in more tracheal intubation attempts, an important risk factor for intubation-associated complications. Targeted education of clinicians may reduce the incidence of technical difficulties.

  7. Quality of Widely Available Video Instructional Materials for Point-of-Care Ultrasound-Guided Procedure Training in Internal Medicine.

    PubMed

    Khandelwal, Aditi; Devine, Luke A; Otremba, Mirek

    2017-07-01

    Many instructional materials for point-of-care ultrasound (US)-guided procedures exist; however, their quality is unknown. This study assessed widely available educational videos for point-of-care US-guided procedures relevant to internal medicine: central venous catheterization, thoracentesis, and paracentesis. We searched Ovid MEDLINE, YouTube, and Google to identify videos for point-of-care US-guided paracentesis, thoracentesis, and central venous catheterization. Videos were evaluated with a 5-point scale assessing the global educational value and a checklist based on consensus guidelines for competencies in point-of-care US-guided procedures. For point-of-care US-guided central venous catheterization, 12 videos were found, with an average global educational value score ± SD of 4.5 ± 0.7. Indications to abort the procedure were discussed in only 3 videos. Five videos described the indications and contraindications for performing central venous catheterization. For point-of-care US-guided thoracentesis, 8 videos were identified, with an average global educational value score of 4.0 ± 0.9. Only one video discussed indications to abort the procedure, and 3 videos discussed sterile technique. For point-of-care US-guided paracentesis, 7 videos were included, with an average global educational value score of 4.1 ± 0.9. Only 1 video discussed indications to abort the procedure, and 2 described the location of the inferior epigastric artery. The 27 videos reviewed contained good-quality general instruction. However, we noted a lack of safety-related information in most of the available videos. Further development of resources is required to teach internal medicine trainees skills that focus on the safety of point-of-care US guidance. © 2017 by the American Institute of Ultrasound in Medicine.

  8. A 26-year-old man with dyspnea and chest pain.

    PubMed

    Mittal, Saurabh; Jain, Akanksha; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep; Madan, Karan

    2017-01-01

    A 26-year-old smoker male presented with a history of sudden onset dyspnea and right-sided chest pain. Chest radiograph revealed large right-sided pneumothorax which was managed with tube thoracostomy. High-resolution computed tomography thorax revealed multiple lung cysts, and for a definite diagnosis, a video-assisted thoracoscopic surgery-guided lung biopsy was performed followed by pleurodesis. This clinicopathologic conference discusses the clinical and radiological differential diagnoses, utility of lung biopsy, and management options for patients with such a clinical presentation.

  9. A 26-year-old man with dyspnea and chest pain

    PubMed Central

    Mittal, Saurabh; Jain, Akanksha; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep; Madan, Karan

    2017-01-01

    A 26-year-old smoker male presented with a history of sudden onset dyspnea and right-sided chest pain. Chest radiograph revealed large right-sided pneumothorax which was managed with tube thoracostomy. High-resolution computed tomography thorax revealed multiple lung cysts, and for a definite diagnosis, a video-assisted thoracoscopic surgery-guided lung biopsy was performed followed by pleurodesis. This clinicopathologic conference discusses the clinical and radiological differential diagnoses, utility of lung biopsy, and management options for patients with such a clinical presentation. PMID:29099006

  10. Aquatic Plant Control Research Program: Aquatic Plant Identification and Herbicide Use Guide. Volume 2. Aquatic Plants and Susceptibility to Herbicides

    DTIC Science & Technology

    1988-11-01

    axils of the minute scale leaves of a where flowers with stalks are arranged tuber along an elongated axis tuft - cluster of leaves or other elon ...long, blue-purple, asymmetrical, crowded in elon - gated terminal spikes, each flower with 6 petal-like parts united below into a tube, blooming from...syn.: C. echinatum Gray), has more 1 mm spines per fruit and is apparently less com- mon. Ceratophyllun may be confused with Chara ( musk grass

  11. The Application of Particle Image Velocimetry (PIV) in a Short Duration Transonic Annular Turbine Cascade

    DTIC Science & Technology

    1991-03-01

    series of experiments have been performed to create a plane of light with a ruby pulse laser and photograph demonstrate the application of Particle...using a SIT 1. INTRODUCTION (silicon intensified tube) camera developed 6y Wernet at NASA Lewis (1989). Optical diagnostics have now become essential...lens for the PIV tests. Fig 2 shows a photograph of the As a result of this the potential sensitivity of the technique has nozzle guide vanes

  12. New technique for treating pseudocyst of the auricle.

    PubMed

    Zhu, L X; Wang, X Y

    1990-01-01

    Although pseudocyst of the auricle is a common disease in China, its cause and mechanism are still not clear. Several methods of treatment have been advocated: repeated aspirations combined with physiotherapy, and incision and drainage with contour pressure dressing, magnetotherapy etc. In recent years, a new technique with a drainage tube inserted into the pseudocyst using a guide needle has been used in our hospital in the treatment of this condition. We report 45 cases treated by this method, none of whom had the condition previously.

  13. Simultaneous MRI and PET imaging of a rat brain

    NASA Astrophysics Data System (ADS)

    Raylman, Raymond R.; Majewski, Stan; Lemieux, Susan K.; Sendhil Velan, S.; Kross, Brian; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Zorn, Carl; Marano, Gary D.

    2006-12-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging.

  14. An acoustical guidance and position monitoring system for endotracheal tubes.

    PubMed

    Mansfield, J P; Lyle, R P; Voorhees, W D; Wodicka, G R

    1993-12-01

    A prototype instrument to guide the placement and continuously monitor the position of an endotracheal tube (ETT) was developed. An incident audible sound pulse is introduced into the proximal ETT and detected as it travels down the ETT via a miniature microphone located in the wall. This pulse is then emitted from the tube tip into the airways and the reflected signal from the airways is detected by the microphone. A well defined reflection arises from the point where the total cross sectional area of the airways increases rapidly, and the difference in timing between detection of the incident pulse and this reflection is used to determine ETT position or movement. This reflection is not observed if the ETT is erroneously placed in the esophagus. The amplitude and polarity of an additional reflection that occurs at the ETT tip is used to estimate the cross-sectional area of the airway in which the ETT is placed. This combined information allows discrimination between tracheal and bronchial intubation and can be used to insure an adequate fit between the ETT and trachea. The instrument has proven extremely reliable in multiple intubations in eight canines and offers the potential to noninvasively and inexpensively monitor ETT position in a continuous manner.

  15. A deflectable guiding catheter for real-time MRI-guided interventions

    PubMed Central

    Bell, Jamie A.; Saikus, Christina E.; Ratnakaya, Kanishka; Wu, Vincent; Sonmez, Merdim; Faranesh, Anthony Z.; Colyer, Jessica H.; Lederman, Robert J.; Kocaturk, Ozgur

    2011-01-01

    Purpose To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures. Materials and Methods The catheter shaft incorporated Kevlar braiding. 180° deflection was attained with a 5 cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively-coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine. Results Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo. Conclusion Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057” lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements. PMID:22128071

  16. TU-E-TOUR-I-00: Exhibit Hall Guided Tours-Dosimters for QC in Diagnostic Imaging (Tuesday)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Christina Sammet, Lurie Children’s Hospital of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introductionmore » and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.« less

  17. WE-C-TOUR-I-00: Exhibit Hall Guided Tours-Dosimters for QC in Diagnostic Imaging (Wednesday)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Adrien Sanchez, University of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and backgroundmore » given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.« less

  18. A Case of Massive Pleural Effusion: Pleurodesis by Bleomycin.

    PubMed

    Hasan, R; Khan, O S; Aftabuddin, M; Razzaque, A M; Chowdhury, G A

    2016-04-01

    Malignant pleural effusion is a common complication of primary and metastatic pleural malignancies. Pleurodesis for the management of malignant pleural effusion is intended to achieve symphysis between parietal and visceral pleura, and to prevent relapse of pleural effusion. Many chemical agents are tried to induce inflammation and damage of the pleural mesothelial layer to achieve this symphysis. Hemorrhagic pleural effusion, especially in the right hemithorax commonly occurs as presentation of primary and metastatic pleural malignancies. This case reports massive right-sided hemorrhagic pleural effusion as the sole manifestation of primary lung cancer in a 45 year old man. Patient attended our department of thoracic surgery complaining of cough, shortness of breath and right sided chest pain. A chest X-ray and chest computer tomography (CT) radiograph shows right sided massive pleural effusion. Right sided tube thoracotomy done. Pleural fluid study was done. Fluid for cytopathology was positive for malignant cell. Computed tomography guided fine needle aspiration cytology from right lung lesion was also done. Diagnosis was as small cell carcinoma. Pleural effusion resolved after 9(th) post operative day of chest tube insertion. Bleomycin pleurodesis was done. Day after pleurodesis intra thoracic tube was removed and patient was discharged from hospital on 10(th) Post operative day with an advice to attend the oncology department for further treatment. The protocol of tube thoracostomy and chemical pleurodesis was almost always successful in giving symptomatic relief of respiratory distress for a considerable period of time. However, chemical pleurodesis is not possible in all cases of malignant pleural effusion because it has got potential complication including death.

  19. Surface current balance and thermoelectric whistler wings at airless astrophysical bodies: Cassini at Rhea.

    PubMed

    Teolis, B D; Sillanpää, I; Waite, J H; Khurana, K K

    2014-11-01

    Sharp magnetic perturbations found by the Cassini spacecraft at the edge of the Rhea flux tube are consistent with field-aligned flux tube currents. The current system results from the difference of ion and electron gyroradii and the requirement to balance currents on the sharp Rhea surface. Differential-type hybrid codes that solve for ion velocity and magnetic field have an intrinsic difficulty modeling the plasma absorber's sharp surface. We overcome this problem by instead using integral equations to solve for ion and electron currents and obtain agreement with the magnetic perturbations at Rhea's flux tube edge. An analysis of the plasma dispersion relations and Cassini data reveals that field-guided whistler waves initiated by (1) the electron velocity anisotropy in the flux tube and (2) interaction with surface sheath electrostatic waves on topographic scales may facilitate propagation of the current system to large distances from Rhea. Current systems like those at Rhea should occur generally, for plasma absorbers of any size such as spacecraft or planetary bodies, in a wide range of space plasma environments. Motion through the plasma is not essential since the current system is thermodynamic in origin, excited by heat flow into the object. The requirements are a difference of ion and electron gyroradii and a sharp surface, i.e., without a significant thick atmosphere. Surface current balance condition yields a current system at astronomical bodiesCurrent system possible for sharp (airless) objects of any sizeCurrent system is thermoelectric and motion through the plasma nonessential.

  20. Surface current balance and thermoelectric whistler wings at airless astrophysical bodies: Cassini at Rhea

    PubMed Central

    Teolis, B D; Sillanpää, I; Waite, J H; Khurana, K K

    2014-01-01

    Sharp magnetic perturbations found by the Cassini spacecraft at the edge of the Rhea flux tube are consistent with field-aligned flux tube currents. The current system results from the difference of ion and electron gyroradii and the requirement to balance currents on the sharp Rhea surface. Differential-type hybrid codes that solve for ion velocity and magnetic field have an intrinsic difficulty modeling the plasma absorber's sharp surface. We overcome this problem by instead using integral equations to solve for ion and electron currents and obtain agreement with the magnetic perturbations at Rhea's flux tube edge. An analysis of the plasma dispersion relations and Cassini data reveals that field-guided whistler waves initiated by (1) the electron velocity anisotropy in the flux tube and (2) interaction with surface sheath electrostatic waves on topographic scales may facilitate propagation of the current system to large distances from Rhea. Current systems like those at Rhea should occur generally, for plasma absorbers of any size such as spacecraft or planetary bodies, in a wide range of space plasma environments. Motion through the plasma is not essential since the current system is thermodynamic in origin, excited by heat flow into the object. The requirements are a difference of ion and electron gyroradii and a sharp surface, i.e., without a significant thick atmosphere. Key Points Surface current balance condition yields a current system at astronomical bodies Current system possible for sharp (airless) objects of any size Current system is thermoelectric and motion through the plasma nonessential PMID:26167436

  1. Portrayal of Alcohol Brands Popular Among Underage Youth on YouTube: A Content Analysis.

    PubMed

    Primack, Brian A; Colditz, Jason B; Rosen, Eva B; Giles, Leila M; Jackson, Kristina M; Kraemer, Kevin L

    2017-09-01

    We characterized leading YouTube videos featuring alcohol brand references and examined video characteristics associated with each brand and video category. We systematically captured the 137 most relevant and popular videos on YouTube portraying alcohol brands that are popular among underage youth. We used an iterative process to codebook development. We coded variables within domains of video type, character sociodemographics, production quality, and negative and positive associations with alcohol use. All variables were double coded, and Cohen's kappa was greater than .80 for all variables except age, which was eliminated. There were 96,860,936 combined views for all videos. The most common video type was "traditional advertisements," which comprised 40% of videos. Of the videos, 20% were "guides" and 10% focused on chugging a bottle of distilled spirits. While 95% of videos featured males, 40% featured females. Alcohol intoxication was present in 19% of videos. Aggression, addiction, and injuries were uncommonly identified (2%, 3%, and 4%, respectively), but 47% of videos contained humor. Traditional advertisements represented the majority of videos related to Bud Light (83%) but only 18% of Grey Goose and 8% of Hennessy videos. Intoxication was most present in chugging demonstrations (77%), whereas addiction was only portrayed in music videos (22%). Videos containing humor ranged from 11% for music-related videos to 77% for traditional advertisements. YouTube videos depicting the alcohol brands favored by underage youth are heavily viewed, and the majority are traditional or narrative advertisements. Understanding characteristics associated with different brands and video categories may aid in intervention development.

  2. Comprehensive analysis of tobacco pollen transcriptome unveils common pathways in polar cell expansion and underlying heterochronic shift during spermatogenesis

    PubMed Central

    2012-01-01

    Background Many flowering plants produce bicellular pollen. The two cells of the pollen grain are destined for separate fates in the male gametophyte, which provides a unique opportunity to study genetic interactions that govern guided single-cell polar expansion of the growing pollen tube and the coordinated control of germ cell division and sperm cell fate specification. We applied the Agilent 44 K tobacco gene chip to conduct the first transcriptomic analysis of the tobacco male gametophyte. In addition, we performed a comparative study of the Arabidopsis root-hair trichoblast transcriptome to evaluate genetic factors and common pathways involved in polarized cell-tip expansion. Results Progression of pollen grains from freshly dehisced anthers to pollen tubes 4 h after germination is accompanied with > 5,161 (14.9%) gametophyte-specific expressed probes active in at least one of the developmental stages. In contrast, > 18,821 (54.4%) probes were preferentially expressed in the sporophyte. Our comparative approach identified a subset of 104 pollen tube-expressed genes that overlap with root-hair trichoblasts. Reverse genetic analysis of selected candidates demonstrated that Cu/Zn superoxide dismutase 1 (CSD1), a WD-40 containing protein (BP130384), and Replication factor C1 (NtRFC1) are among the central regulators of pollen-tube tip growth. Extension of our analysis beyond the second haploid mitosis enabled identification of an opposing-dynamic accumulation of core regulators of cell proliferation and cell fate determinants in accordance with the progression of the germ cell cycle. Conclusions The current study provides a foundation to isolate conserved regulators of cell tip expansion and those that are unique for pollen tube growth to the female gametophyte. A transcriptomic data set is presented as a benchmark for future functional studies using developing pollen as a model. Our results demonstrated previously unknown functions of certain genes in pollen-tube tip growth. In addition, we highlighted the molecular dynamics of core cell-cycle regulators in the male gametophyte and postulated the first genetic model to account for the differential timing of spermatogenesis among angiosperms and its coordination with female gametogenesis. PMID:22340370

  3. A survey of nitrogen dioxide concentrations in the United Kingdom using diffusion tubes, July-December 1991

    NASA Astrophysics Data System (ADS)

    Campbell, G. W.; Stedman, J. R.; Stevenson, K.

    Palmes diffusion tubes have been used to measure nitrogen dioxide concentration at 363 urban sites throughout the United Kingdom during the period of July-December 1991. Average concentrations over the period ranged from les than 10 ppb in northern Scotland to around 50 ppb at near-road sites in London. A total of 243 sites provided valid data for both this survey and an earlier, similar, study in 1986. On average, concentrations were about 34% larger in 1991. Increases occurred throughout the country and were not confined to any particular area or region, although the percentage change tended to be larger in the north and west and where concentrations were small. The observed difference in concentrations was consistent with differences in meteorological conditions between the periods covered by the two surveys and the 38% increase in emissions of NO x from motor vehicles over the period. However, there is no evidence from continuous monitoring between 1987 and 1991 of a marked trend in concentration at any one site. The shortening of the diffusion path in the diffusion tube due to wind effects has been demonstrated. This leads to a tendency for diffusion tubes to overread relative to chemiluminescent analysers. However, if the tubes are mounted in a sheltered location the overestimate is small. Since, in this survey, most of the samplers were mounted close to the sides of buildings, the data were not corrected, although the concentrations may be overestimates at some sites. In order to provide information on the spatial distribution of NO 2 over the whole country, population density (related to vehicle density) was used along with the survey results together with additional data on rural concentrations, to map NO 2 concentrations over Great Britain. This suggests that around one third of the population lives in regions where the mean concentration exceeds the European Community Directive Guide Value for median concentration. However this proportion would be reduced if the tendency for the tubes to overread and the fact that the mean value is generally larger than the median were taken into account.

  4. Power break off in a bulb turbine: wall pressure sensor investigation

    NASA Astrophysics Data System (ADS)

    Duquesne, P.; Maciel, Y.; Aeschlimann, V.; Ciocan, G. D.; Deschênes, C.

    2014-03-01

    A measurement campaign using unsteady wall pressure sensors on a bulb turbine draft tube was performed over the power and efficiency break off range of a N11 curve. This study is part of the BulbT project, undertaken by the Consortium on hydraulic machines and the LAMH (Hydraulic Machine Laboratory of Laval University). The chosen operating points include the best efficiency point for a high runner blade angle and a high N11. Three other points, with the same N11, have been selected in the break off zone of the efficiency curve. Flow conditions have been set using the guide vanes while the runner blade angle remained constant. The pressure sensors were developed from small piezoresistive chips with high frequency response. The calibration gave an instrumental error lower than 0.3% of the measurement range. The unsteady wall pressure was measured simultaneously at 13 locations inside the first part of the draft tube, which is conical, and at 16 locations in the circular to rectangular transition part just downstream. It was also measured at 11 locations along a streamwise line path at the bottom left part of the draft tube, where flow separation occurs, covering the whole streamwise extent of the draft tube. For seven radial-azimuthal planes, four sensors were distributed azimuthally. As confirmed by tuft visualizations, the break off phenomenon is correlated to the presence of flow separation inside the diffuser at the wall. The break off is linked to the appearance of a large recirculation in the draft tube. The efficiency drop increases with the size of the separated region. Analysis of the draft tube pressure coefficients confirms that the break off is related to diffuser losses. The streamwise evolution of the mean pressure coefficient is analyzed for the different operating conditions. An azimuthal dissymmetry of the mean pressure produced by the separation is detected. The pressure signals have been analyzed and used to track the separation zone depending on the operating conditions. Spectral analysis of these signals reveals a low frequency unsteadiness generated by the flow separation.

  5. Understanding Fast and Robust Thermo-osmotic Flows through Carbon Nanotube Membranes: Thermodynamics Meets Hydrodynamics.

    PubMed

    Fu, Li; Merabia, Samy; Joly, Laurent

    2018-04-19

    Following our recent theoretical prediction of the giant thermo-osmotic response of the water-graphene interface, we explore the practical implementation of waste heat harvesting with carbon-based membranes, focusing on model membranes of carbon nanotubes (CNT). To that aim, we combine molecular dynamics simulations and an analytical model considering the details of hydrodynamics in the membrane and at the tube entrances. The analytical model and the simulation results match quantitatively, highlighting the need to take into account both thermodynamics and hydrodynamics to predict thermo-osmotic flows through membranes. We show that, despite viscous entrance effects and a thermal short-circuit mechanism, CNT membranes can generate very fast thermo-osmotic flows, which can overcome the osmotic pressure of seawater. We then show that in small tubes confinement has a complex effect on the flow and can even reverse the flow direction. Beyond CNT membranes, our analytical model can guide the search for other membranes to generate fast and robust thermo-osmotic flows.

  6. Impact of compressibility and a guide field on Fermi acceleration during magnetic island coalescence

    NASA Astrophysics Data System (ADS)

    Montag, P.; Egedal, J.; Lichko, E.; Wetherton, B.

    2017-06-01

    Previous work has shown that Fermi acceleration can be an effective heating mechanism during magnetic island coalescence, where electrons may undergo repeated reflections as the magnetic field lines contract. This energization has the potential to account for the power-law distributions of particle energy inferred from observations of solar flares. Here, we develop a generalized framework for the analysis of Fermi acceleration that can incorporate the effects of compressibility and non-uniformity along field lines, which have commonly been neglected in previous treatments of the problem. Applying this framework to the simplified case of the uniform flux tube allows us to find both the power-law scaling of the distribution function and the rate at which the power-law behavior develops. We find that a guide magnetic field of order unity effectively suppresses the development of power-law distributions.

  7. Barriers to front propagation in laminar, three-dimensional fluid flows

    NASA Astrophysics Data System (ADS)

    Doan, Minh; Simons, J. J.; Lilienthal, Katherine; Solomon, Tom; Mitchell, Kevin A.

    2018-03-01

    We present experiments on one-way barriers that block reaction fronts in a fully three-dimensional (3D) fluid flow. Fluorescent Belousov-Zhabotinsky reaction fronts are imaged with laser-scanning in a laminar, overlapping vortex flow. The barriers are analyzed with a 3D extension to burning invariant manifold (BIM) theory that was previously applied to two-dimensional advection-reaction-diffusion processes. We discover tube and sheet barriers that guide the front evolution. The experimentally determined barriers are explained by BIMs calculated from a model of the flow.

  8. Haptic device for colonoscopy training simulator.

    PubMed

    Kwon, Jun Yong; Woo, Hyun Soo; Lee, Doo Yong

    2005-01-01

    A new 2-DOF haptic device for colonoscopy training simulator employing flexible endoscopes, is developed. The user operates the device in translational and roll directions. The developed folding guides of the device keep the endoscope tube straight. This helps transmit large decoupled forces of the colonoscopy simulation to the user. The device also includes a mechanism to detect jiggling motion of the scopes to allow users to practice this important skill of the colonoscopy. The device includes PD controller to compensate the inertia and friction effects. This provides the users with better transparent sensation of the simulation.

  9. CT evaluation of thoracic infections after major trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mirvis, S.E.; Rodriguez, A.; Whitley, N.O.

    1985-06-01

    Thirty-seven septic patients with major multisystem trauma were evaluated by computed tomography (CT) to identify possible thoracic sources of infection. CT was 72% accurate in the diagnosis of empyema and 95% accurate in the diagnosis of lung abscess. While CT proved useful in demonstrating these sites of thoracic infections in septic trauma victims, the presence of concurrent thoracic pathology, particularly loculated hemothorax or hemopneumothorax and traumatic lung cysts with hemorrhage or surrounding parenchymal consolidation, introduced sources of diagnostic error. CT also proved helpful in guiding appropriate revisions of malpositioned and occluded thoracostomy tubes.

  10. Effect of surgical guide design and surgeon's experience on the accuracy of implant placement.

    PubMed

    Hinckfuss, Simon; Conrad, Heather J; Lin, Lianshan; Lunos, Scott; Seong, Wook-Jin

    2012-08-01

    Implant position is a key determinant of esthetic and functional success. Achieving the goal of ideal implant position may be affected by case selection, prosthodontically driven treatment planning, site preparation, surgeon's experience and use of a surgical guide. The combined effect of surgical guide design, surgeon's experience, and size of the edentulous area on the accuracy of implant placement was evaluated in a simulated clinical setting. Twenty-one volunteers were recruited to participate in the study. They were divided evenly into 3 groups (novice, intermediate, and experienced). Each surgeon placed implants in single and double sites using 4 different surgical guide designs (no guide, tube, channel, and guided) and written instructions describing the ideal implant positions. A definitive typodont was constructed that had 3 implants in prosthetically determined ideal positions of single and double sites. The position and angulation of implants placed by the surgeons in the duplicate typodonts was measured using a computerized coordinate measuring machine and compared to the definitive typodont. The mean absolute positional error for all guides was 0.273, 0.340, 0.197 mm in mesial-distal, buccal-lingual, vertical positions, respectively, with an overall range of 0.00 to 1.81 mm. The mean absolute angle error for all guides was 1.61° and 2.39° in the mesial-distal and buccal-lingual angulations, respectively, with an overall range of 0.01° to 9.7°. Surgical guide design had a statistically significant effect on the accuracy of implant placement regardless of the surgeon's experience level. Experienced surgeons had significantly less error in buccal-lingual angulation. The size of the edentulous sites was found to affect both implant angle and position significantly. The magnitude of error in position and angulation caused by surgical guide design, surgeon's experience, and site size reported in this study are possibly not large enough to be clinically significant; however, it is likely that errors would be magnified in clinical practice. Future research is recommended to evaluate the effect of surgical guide design in vivo on implant angulation and position error.

  11. Study on the application of shear-wave elastography to thin-layered media and tubular structure: Finite-element analysis and experiment verification

    NASA Astrophysics Data System (ADS)

    Jang, Jun-keun; Kondo, Kengo; Namita, Takeshi; Yamakawa, Makoto; Shiina, Tsuyoshi

    2016-07-01

    Shear-wave elastography (SWE) enables the noninvasive and quantitative evaluation of the mechanical properties of human soft tissue. Generally, shear-wave velocity (C S) can be estimated using the time-of-flight (TOF) method. Young’s modulus is then calculated directly from the estimated C S. However, because shear waves in thin-layered media propagate as guided waves, C S cannot be accurately estimated using the conventional TOF method. Leaky Lamb dispersion analysis (LLDA) has recently been proposed to overcome this problem. In this study, we performed both experimental and finite-element (FE) analyses to evaluate the advantages of LLDA over TOF. In FE analysis, we investigated why the conventional TOF is ineffective for thin-layered media. In phantom experiments, C S results estimated using the two methods were compared for 1.5 and 2% agar plates and tube phantoms. Furthermore, it was shown that Lamb waves can be applied to tubular structures by extracting lateral waves traveling in the long axis direction of the tube using a two-dimensional window. Also, the effects of the inner radius and stiffness (or shear wavelength) of the tube on the estimation performance of LLDA were experimentally discussed. In phantom experiments, the results indicated good agreement between LLDA (plate phantoms of 2 mm thickness: 5.0 m/s for 1.5% agar and 7.2 m/s for 2% agar; tube phantoms with 2 mm thickness and 2 mm inner radius: 5.1 m/s for 1.5% agar and 7.0 m/s for 2% agar; tube phantoms with 2 mm thickness and 4 mm inner radius: 5.3 m/s for 1.5% agar and 7.3 m/s for 2% agar) and SWE measurements (bulk phantoms: 5.3 m/s ± 0.27 for 1.5% agar and 7.3 m/s ± 0.54 for 2% agar).

  12. Laparoscopic vs computerized tomography-guided radiofrequency ablation for large hepatic hemangiomas abutting the diaphragm

    PubMed Central

    Gao, Jun; Kong, Jian; Ding, Xue-Mei; Ke, Shan; Niu, Hai-Gang; Xin, Zong-Hai; Ning, Chun-Min; Guo, Shi-Gang; Li, Xiao-Long; Zhang, Long; Dong, Yong-Hong; Sun, Wen-Bing

    2015-01-01

    AIM: To compare safety and therapeutic efficacy of laparoscopic radiofrequency (RF) ablation vs computed tomography (CT)-guided RF ablation for large hepatic hemangiomas abutting the diaphragm. METHODS: We retrospectively reviewed our sequential experience of treating 51 large hepatic hemangiomas abutting the diaphragm in 51 patients by CT-guided or laparoscopic RF ablation due to either the presence of symptoms and/or the enlargement of hemangioma. Altogether, 24 hemangiomas were ablated via a CT-guided percutaneous approach (CT-guided ablation group), and 27 hemangiomas were treated via a laparoscopic approach (laparoscopic ablation group). RESULTS: The mean diameter of the 51 hemangiomas was 9.6 ± 1.8 cm (range, 6.0-12.0 cm). There was no difference in the diameter of hemangiomas between the two groups (P > 0.05). RF ablation was performed successfully in all patients. There was no difference in ablation times between groups (P > 0.05). There were 23 thoracic complications in 17 patients: 15 (62.5%, 15/24) in the CT-guided ablation group and 2 (7.4%, 2/27) in the laparoscopic ablation group (P < 0.05). According to the Dindo-Clavien classification, two complications (pleural effusion and diaphragmatic rupture grade III) were major in two patients. All others were minor (grade I). Both major complications occurred in the CT-guided ablation group. The minor complications were treated successfully with conservative measures, and the two major complications underwent treatment by chest tube drainage and thoracoscopic surgery, respectively. Complete ablation was achieved in 91.7% (22/24) and 96.3% (26/27) in the CT-guided and the laparoscopic ablation groups, respectively (P > 0.05). CONCLUSION: Laparoscopic RF ablation therapy should be used as the first-line treatment option for large hepatic hemangiomas abutting the diaphragm. It avoids thermal injury to the diaphragm and reduces thoracic complications. PMID:26019459

  13. Phase Imaging using Focusing Polycapillary Optics

    NASA Astrophysics Data System (ADS)

    Bashir, Sajid

    The interaction of X rays in diagnostic energy range with soft tissues can be described by Compton scattering and by the complex refractive index, which together characterize the attenuation properties of the tissue and the phase imparted to X rays passing through it. Many soft tissues exhibit extremely similar attenuation, so that their discrimination using conventional radiography, which generates contrast in an image through differential attenuation, is challenging. However, these tissues will impart phase differences significantly greater than attenuation differences to the X rays passing through them, so that phase-contrast imaging techniques can enable their discrimination. A major limitation to the widespread adoption of phase-contrast techniques is that phase contrast requires significant spatial coherence of the X-ray beam, which in turn requires specialized sources. For tabletop sources, this often requires a small (usually in the range of 10-50 micron) X-ray source. In this work, polycapillary optics were employed to create a small secondary source from a large spot rotating anode. Polycapillary optics consist of arrays of small hollow glass tubes through which X rays can be guided by total internal reflection from the tube walls. By tapering the tubes to guide the X rays to a point, they can be focused to a small spot which can be used as a secondary source. The polycapillary optic was first aligned with the X-ray source. The spot size was measured using a computed radiography image plate. Images were taken at a variety of optic-to-object and object-to-detector distances and phase-contrast edge enhancement was observed. Conventional absorption images were also acquired at a small object-to detector distances for comparison. Background division was performed to remove strong non-uniformity due to the optics. Differential phase contrast reconstruction demonstrates promising preliminary results. This manuscript is divided into six chapters. The second chapter describes the limitations of conventional imaging methods and benefits of the phase imaging. Chapter three covers different types of X-ray photon interactions with matter. Chapter four describes the experimental set-up and different types of images acquired along with their analysis. Chapter five summarizes the findings in this project and describes future work as well.

  14. Functional regeneration of recurrent laryngeal nerve injury during thyroid surgery using an asymmetrically porous nerve guide conduit in an animal model.

    PubMed

    Choi, Jeong-Seok; Oh, Se Heang; An, Hye-Young; Kim, Young-Mo; Lee, Jin Ho; Lim, Jae-Yol

    2014-01-01

    Vocal cord paralysis (VCP) caused by recurrent laryngeal nerve (RLN) damage during thyroidectomy commonly results in serious medico-legal problems. The purpose of this study was to evaluate the usefulness of an asymmetrically porous polycaprolactone (PCL)/Pluronic F127 nerve guide conduit (NGC) for functional regeneration in a RLN injury animal model. A biodegradable, asymmetrically porous PCL/F127 NGC with selective permeability was fabricated for use in this study. A 10-mm segment of left RLN was resected in 28 New Zealand white rabbits, and then an asymmetrically porous NGC or a nonporous silicone tube was interposed between both stumps and securely fixed. Vocal cord mobility was endoscopically evaluated at one, four, and eight weeks postoperatively. Nerve growth through NGCs was assessed by toluidine blue staining, and thyroarytenoid (TA) muscle atrophy was evaluated by hematoxylin and eosin staining. Immunohistochemical stainings for acetylcholinesterase (AchE), anti-neurofilament (NF), and anti-S100 protein were also conducted, and transmission electron microscopy (TEM) was used to evaluate functional nerve regeneration. At eight weeks postoperatively, endoscopic evaluations showed significantly better recovery from VCP in the asymmetrically porous PCL/F127 NGC group (6 of 10 rabbits) than in the silicone tube group (1 of 10 rabbits). Continued nerve growth on the damaged nerve endings was observed with time in the asymmetrically porous PCL/F127 NGC-interposed RLNs. TA muscle dimensions and AchE expressions in TA muscle were significantly greater in the asymmetrically porous PCL/F127 NGC group than in the silicone tube group. Furthermore, immunohistochemical staining revealed the expression of NF and S100 protein in the regenerated nerves in the asymmetrically porous PCL/F127 NGC group at eight weeks postoperatively, and at this time, TEM imaging showed myelinated axons in the regenerated RLNs. The study shows that asymmetrically porous PCL/F127 NGC provides a favorable environment for RLN regeneration and that it has therapeutic potential for the regeneration of RLN damage.

  15. Functional Regeneration of Recurrent Laryngeal Nerve Injury During Thyroid Surgery Using an Asymmetrically Porous Nerve Guide Conduit in an Animal Model

    PubMed Central

    Choi, Jeong-Seok; Oh, Se Heang; An, Hye-Young; Kim, Young-Mo; Lee, Jin Ho

    2014-01-01

    Background: Vocal cord paralysis (VCP) caused by recurrent laryngeal nerve (RLN) damage during thyroidectomy commonly results in serious medico-legal problems. The purpose of this study was to evaluate the usefulness of an asymmetrically porous polycaprolactone (PCL)/Pluronic F127 nerve guide conduit (NGC) for functional regeneration in a RLN injury animal model. Methods: A biodegradable, asymmetrically porous PCL/F127 NGC with selective permeability was fabricated for use in this study. A 10-mm segment of left RLN was resected in 28 New Zealand white rabbits, and then an asymmetrically porous NGC or a nonporous silicone tube was interposed between both stumps and securely fixed. Vocal cord mobility was endoscopically evaluated at one, four, and eight weeks postoperatively. Nerve growth through NGCs was assessed by toluidine blue staining, and thyroarytenoid (TA) muscle atrophy was evaluated by hematoxylin and eosin staining. Immunohistochemical stainings for acetylcholinesterase (AchE), anti-neurofilament (NF), and anti-S100 protein were also conducted, and transmission electron microscopy (TEM) was used to evaluate functional nerve regeneration. Results: At eight weeks postoperatively, endoscopic evaluations showed significantly better recovery from VCP in the asymmetrically porous PCL/F127 NGC group (6 of 10 rabbits) than in the silicone tube group (1 of 10 rabbits). Continued nerve growth on the damaged nerve endings was observed with time in the asymmetrically porous PCL/F127 NGC-interposed RLNs. TA muscle dimensions and AchE expressions in TA muscle were significantly greater in the asymmetrically porous PCL/F127 NGC group than in the silicone tube group. Furthermore, immunohistochemical staining revealed the expression of NF and S100 protein in the regenerated nerves in the asymmetrically porous PCL/F127 NGC group at eight weeks postoperatively, and at this time, TEM imaging showed myelinated axons in the regenerated RLNs. Conclusion: The study shows that asymmetrically porous PCL/F127 NGC provides a favorable environment for RLN regeneration and that it has therapeutic potential for the regeneration of RLN damage. PMID:24015805

  16. Experimental analysis of the flow pattern of a pump turbine model in pump mode

    NASA Astrophysics Data System (ADS)

    Guggenberger, Mark; Senn, Florian; Jaberg, Helmut; Gehrer, Arno; Sallaberger, Manfred; Widmer, Christian

    2016-11-01

    Reversible pump turbines are the only means to store primary energy in an highly efficient way. Within a short time their operation can be switched between the different operational regimes thus enhancing the stabilization of the electric grid. These qualities in combination with the operation even at off-design conditions offer a high flexibility to the energy market. However, pump turbines pass through operational regimes where their behaviour becomes unstable. One of these effects occurs when the flowrate is decreased continuously down to a minimum. This point is the physical limitation of the pump operation and is very difficult to predict properly by numerical design without a model test. The purpose of the present study is to identify the fluid mechanical phenomena leading to the occurrence of instabilities of pump turbines in pump mode. A reduced scale model of a ANDRITZ pump turbine was installed on a 4-quadrant test rig for the experimental investigation of unstable conditions in pump mode. The performed measurements are based on the IEC60193-standard. Characteristic measurements at a single guide vane opening were carried out to get a detailed insight into the instabilities in pump mode. The interaction between runner and guide vane was analysed by Particle Image Velocimetry. Furthermore, high-speed visualizations of the suction side part load flow and the suction recirculation were performed. Like never before the flow pattern in the draft tube cone became visible with the help of a high-speed camera by intentionally caused cavitation effects which allow a qualitative view on the flow pattern in the draft tube cone. Suction recirculation is observed in form of single vortices separating from each runner blade and stretching into the draft tube against the main flow direction. To find an explanation for the flow phenomena responsible for the appearance of the unstable head curve also characteristic velocity distributions on the pressure side were combined with high-speed visualizations on the suction side of the pump turbine model. The results enhance the comprehension of the physical background leading to the instability and improve the numerical predictability of the instability in pump mode.

  17. A qualitative analysis of methotrexate self-injection education videos on YouTube.

    PubMed

    Rittberg, Rebekah; Dissanayake, Tharindri; Katz, Steven J

    2016-05-01

    The aim of this study is to identify and evaluate the quality of videos for patients available on YouTube for learning to self-administer subcutaneous methotrexate. Using the search term "Methotrexate injection," two clinical reviewers analyzed the first 60 videos on YouTube. Source and search rank of video, audience interaction, video duration, and time since video was uploaded on YouTube were recorded. Videos were classified as useful, misleading, or a personal patient view. Videos were rated for reliability, comprehensiveness, and global quality scale (GQS). Reasons for misleading videos were documented, and patient videos were documented as being either positive or negative towards methotrexate (MTX) injection. Fifty-one English videos overlapped between the two geographic locations; 10 videos were classified as useful (19.6 %), 14 misleading (27.5 %), and 27 personal patient view (52.9 %). Total views of videos were 161,028: 19.2 % useful, 72.8 % patient, and 8.0 % misleading. Mean GQS: 4.2 (±1.0) useful, 1.6 (±1.1) misleading, and 2.0 (±0.9) for patient videos (p < 0.0001). Mean reliability: 3.3 (±0.6) useful, 0.9 (±1.2) misleading, and 1.0 (±0.7) for patient videos (p < 0.0001). Comprehensiveness: 2.2 (±1.9) useful, 0.1 (±0.3) misleading, and 1.5 (±1.5) for patient view videos (p = 0.0027). This study demonstrates a minority of videos are useful for teaching MTX injection. Further, video quality does not correlate with video views. While web video may be an additional educational tool available, clinicians need to be familiar with specific resources to help guide and educate their patients to ensure best outcomes.

  18. Turbulence Resolving Flow Simulations of a Francis Turbine in Part Load using Highly Parallel CFD Simulations

    NASA Astrophysics Data System (ADS)

    Krappel, Timo; Riedelbauch, Stefan; Jester-Zuerker, Roland; Jung, Alexander; Flurl, Benedikt; Unger, Friedeman; Galpin, Paul

    2016-11-01

    The operation of Francis turbines in part load conditions causes high fluctuations and dynamic loads in the turbine and especially in the draft tube. At the hub of the runner outlet a rotating vortex rope within a low pressure zone arises and propagates into the draft tube cone. The investigated part load operating point is at about 72% discharge of best efficiency. To reduce the possible influence of boundary conditions on the solution, a flow simulation of a complete Francis turbine is conducted consisting of spiral case, stay and guide vanes, runner and draft tube. As the flow has a strong swirling component for the chosen operating point, it is very challenging to accurately predict the flow and in particular the flow losses in the diffusor. The goal of this study is to reach significantly better numerical prediction of this flow type. This is achieved by an improved resolution of small turbulent structures. Therefore, the Scale Adaptive Simulation SAS-SST turbulence model - a scale resolving turbulence model - is applied and compared to the widely used RANS-SST turbulence model. The largest mesh contains 300 million elements, which achieves LES-like resolution throughout much of the computational domain. The simulations are evaluated in terms of the hydraulic losses in the machine, evaluation of the velocity field, pressure oscillations in the draft tube and visual comparisons of turbulent flow structures. A pre-release version of ANSYS CFX 17.0 is used in this paper, as this CFD solver has a parallel performance up to several thousands of cores for this application which includes a transient rotor-stator interface to support the relative motion between the runner and the stationary portions of the water turbine.

  19. SHIELDING CONSIDERATIONS FOR THE SMALL ANIMAL RADIATION RESEARCH PLATFORM (SARRP)

    PubMed Central

    Sayler, Elaine; Dolney, Derek; Avery, Stephen; Koch, Cameron

    2014-01-01

    The Small Animal Radiation Research Platform (SARRP) is a commercially available platform designed to deliver conformal, image-guided radiation to small animals using a dual-anode kV x-ray source. At the University of Pennsylvania, a free-standing 2 m3 enclosure was designed to shield the SARRP according to federal code regulating cabinet x-ray systems. The initial design consisted of 4.0-mm-thick lead for all secondary barriers and proved wholly inadequate. Radiation levels outside the enclosure were 15 times higher than expected. Additionally, the leakage appeared to be distributed broadly within the enclosure, so concern arose that a subject might receive significant doses outside the intended treatment field. Thus, a detailed analysis was undertaken to identify and block all sources of leakage. Leakage sources were identified by Kodak X-OmatV (XV) film placed throughout the enclosure. Radiation inside the enclosure was quantified using Gafchromic film. Outside the enclosure, radiation was measured using a survey meter. Sources of leakage included (1) an unnecessarily broad beam exiting the tube, (2) failure of the secondary collimator to confine the primary beam entirely, (3) scatter from the secondary collimator, (4) lack of beam-stop below the treatment volume, and (5) incomplete shielding of the x-ray tube. The exit window was restricted, and a new collimator was designed to address problems (1–3). A beam-stop and additional tube shielding were installed. These modifications reduced internal scatter by more than 100-fold. Radiation outside the enclosure was reduced to levels compliant with federal regulations, provided the SARRP is operated using tube potentials of 175 kV or less. In addition, these simple and relatively inexpensive modifications eliminate the possibility of exposing a larger animal (such as a rat) to significant doses outside the treatment field. PMID:23532076

  20. Real-time image-guided nasogastric feeding tube placement: A case series using Kangaroo with IRIS Technology in an ICU.

    PubMed

    Mizzi, Anna; Cozzi, Silvano; Beretta, Luigi; Greco, Massimiliano; Braga, Marco

    2017-05-01

    Pulmonary misplacement during the blind insertion of enteral feeding tubes is frequent, particularly in ventilated and neurologically impaired patients. This is probably the first clinical study using the Kangaroo Feeding Tube with IRIS technology (IRIS) which incorporates a camera designed to provide anatomic landmark visualization during insertion. The study aim was to evaluate IRIS performance during bedside gastric placement. This is the first prospective study to collect data on the use of IRIS. Twenty consecutive unconscious patients requiring enteral nutrition were recruited at a single center. IRIS placement was considered complete when a clear image of the gastric mucosa appeared. Correct placement was confirmed using a contrast-enhanced abdominal X-ray. To evaluate the device performance over time, the camera was activated every other day up to 17 d postplacement. In 7 (35%) patients, the trachea was initially visualized, requiring a second placement attempt with the same tube. The IRIS camera allowed recognition of the gastric mucosa in 18 (90%) patients. The esophagogastric junction was identified in one patient, while in a second patient the quality of visualization was poor. Contrast-enhanced X-ray confirmed the gastric placement of IRIS in all patients. IRIS allowed identification of gastric mucosa in 14 (70%) patients 3 d after placement. Performance progressively declined with time (P = 0.006, chi-square for trend). IRIS placement could have spared X-ray confirmation in almost all patients and prevented misplacement into the airway in about one third. Visualization quality needs to be improved, particularly after the first week. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. WE-C-TOUR-I-01: Dosimters for QC in Diagnostic Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, X.

    Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Adrien Sanchez, University of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and backgroundmore » given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.« less

  2. Geologic field-trip guide to Medicine Lake Volcano, northern California, including Lava Beds National Monument

    USGS Publications Warehouse

    Donnelly-Nolan, Julie M.; Grove, Timothy L.

    2017-08-17

    Medicine Lake volcano is among the very best places in the United States to see and walk on a variety of well-exposed young lava flows that range in composition from basalt to rhyolite. This field-trip guide to the volcano and to Lava Beds National Monument, which occupies part of the north flank, directs visitors to a wide range of lava flow compositions and volcanic phenomena, many of them well exposed and Holocene in age. The writing of the guide was prompted by a field trip to the California Cascades Arc organized in conjunction with the International Association of Volcanology and Chemistry of the Earth’s Interior (IAVCEI) quadrennial meeting in Portland, Oregon, in August of 2017. This report is one of a group of three guides describing the three major volcanic centers of the southern Cascades Volcanic Arc. The guides describing the Mount Shasta and Lassen Volcanic Center parts of the trip share an introduction, written as an overview to the IAVCEI field trip. However, this guide to Medicine Lake volcano has descriptions of many more stops than are included in the 2017 field trip. The 23 stops described here feature a range of compositions and volcanic phenomena. Many other stops are possible and some have been previously described, but these 23 have been selected to highlight the variety of volcanic phenomena at this rear-arc center, the range of compositions, and for the practical reason that they are readily accessible. Open ground cracks, various vent features, tuffs, lava-tube caves, evidence for glaciation, and lava flows that contain inclusions and show visible evidence of compositional zonation are described and visited along the route.

  3. Automated database-guided expert-supervised orientation for immunophenotypic diagnosis and classification of acute leukemia

    PubMed Central

    Lhermitte, L; Mejstrikova, E; van der Sluijs-Gelling, A J; Grigore, G E; Sedek, L; Bras, A E; Gaipa, G; Sobral da Costa, E; Novakova, M; Sonneveld, E; Buracchi, C; de Sá Bacelar, T; te Marvelde, J G; Trinquand, A; Asnafi, V; Szczepanski, T; Matarraz, S; Lopez, A; Vidriales, B; Bulsa, J; Hrusak, O; Kalina, T; Lecrevisse, Q; Martin Ayuso, M; Brüggemann, M; Verde, J; Fernandez, P; Burgos, L; Paiva, B; Pedreira, C E; van Dongen, J J M; Orfao, A; van der Velden, V H J

    2018-01-01

    Precise classification of acute leukemia (AL) is crucial for adequate treatment. EuroFlow has previously designed an AL orientation tube (ALOT) to guide towards the relevant classification panel (T-cell acute lymphoblastic leukemia (T-ALL), B-cell precursor (BCP)-ALL and/or acute myeloid leukemia (AML)) and final diagnosis. Now we built a reference database with 656 typical AL samples (145 T-ALL, 377 BCP-ALL, 134 AML), processed and analyzed via standardized protocols. Using principal component analysis (PCA)-based plots and automated classification algorithms for direct comparison of single-cells from individual patients against the database, another 783 cases were subsequently evaluated. Depending on the database-guided results, patients were categorized as: (i) typical T, B or Myeloid without or; (ii) with a transitional component to another lineage; (iii) atypical; or (iv) mixed-lineage. Using this automated algorithm, in 781/783 cases (99.7%) the right panel was selected, and data comparable to the final WHO-diagnosis was already provided in >93% of cases (85% T-ALL, 97% BCP-ALL, 95% AML and 87% mixed-phenotype AL patients), even without data on the full-characterization panels. Our results show that database-guided analysis facilitates standardized interpretation of ALOT results and allows accurate selection of the relevant classification panels, hence providing a solid basis for designing future WHO AL classifications. PMID:29089646

  4. Floral signposts: testing the significance of visual ‘nectar guides’ for pollinator behaviour and plant fitness

    PubMed Central

    Hansen, Dennis M.; Van der Niet, Timotheüs; Johnson, Steven D.

    2012-01-01

    Nectar guides, contrasting patterns on flowers that supposedly direct pollinators towards a concealed nectar reward, are taxonomically widespread. However, there have been few studies of their functional significance and effects on plant fitness. Most previous studies focused on pollinator behaviour and used artificial flowers in laboratory settings. We experimentally investigated the role of putative nectar guides in a natural system: the South African iris Lapeirousia oreogena, whose flowers have a clearly visible pattern of six white arrow-markings pointing towards the narrow entrance of the long corolla tube, and its sole pollinator, a long-proboscid nemestrinid fly. We painted over none, some or all of the white arrow-markings with ink that matched the colour of the corolla background. Although arrow-marking removal had little effect on the approaches by flies to flowers from a distance, it dramatically reduced the likelihood of proboscis insertion. Export of pollen dye analogue (an estimate of male fitness) was reduced to almost zero in flowers from which all nectar guides had been removed, and fruit set (a measure of female fitness) was also significantly reduced. Our results confirm that the markings on L. oreogena flowers serve as nectar guides and suggest that they are under strong selective maintenance through both male and female fitness components in this pollination system. PMID:21795269

  5. CT guided transthoracic catheter drainage of intrapulmonary abscess.

    PubMed

    Yunus, Mahira

    2009-10-01

    To determine the efficacy of CT- guided transthoracic catheter drainage of intrapulmonary abscess considering success rate versus complications. This prospective study was carried out at radiology department of Al-Noor Specialist Hospital, Makkah, Saudi Arabia, from 1.1.2003 to 31.12.2005. Nineteen patients were selected for CT guided percutaneous drainage. Under CT guidance catheter placement was carried out using Seldinger technique. Nineteen patients with lung abscess were selected for the percutaneous CT guided drainage. Eight (42.105%) patients encountered no complications and lung abscess completely resolved with no residual cavity. Five (26.31%) patients developed pneumothorax, which was the most common complication of this study. These patients were kept under observation and followed-up by chest X-rays. Three (15.78%) had mild pneumothorax, which resolved and needed no further management, while two (10.52%) patients developed moderate pneumothorax and chest tube was inserted. Two (10.52%) patients developed mild haemoptysis which resolved within two hours, hence, no further management was required. Two (10.52%) patients had residual cavity and surgery was performed. Congenital cystic adenomatoid malformation (CCAM) was found in both cases. Two patients out of nineteen patients (10.52%) developed bronchopleural fistula and were operated. No mortality occurred during or after the procedure. CT allows optimal placement of catheter and hence enables safe and effective percutaneous evacuation of lung abscess. The morbidity and mortality of patients with percutaneous catheter drainage is lower than with surgical resection. Hence, CT guided drainage should be considered the first therapeutic choice in most patients of lung abscess who do not respond to medical therapy.

  6. CT fluoroscopy guided transpleural cutting needle biopsy of small (≤2.5 cm) subpleural pulmonary nodules.

    PubMed

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut; Mostbeck, Gerhard H

    2011-01-01

    Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  7. Analysis of S Characteristics and Pressure Pulsations in a Pump-Turbine With Misaligned Guide Vanes.

    PubMed

    Sun, Hui; Xiao, Ruofu; Liu, Weichao; Wang, Fujun

    2013-05-01

    Growing environmental concerns and the need for better power balancing and frequency control have increased attention in renewable energy sources such as the reversible pump-turbine which can provide both power generation and energy storage. Pump-turbine operation along the S-shaped curve can lead to difficulties in loading the rejection process with unusual increases in water pressure, which lead to machine vibrations. Pressure fluctuations are the primary reason for unstable operation of pump-turbines. Misaligned guide vanes (MGVs) are widely used to control the stability in the S region. There have been experimental investigations and computational fluid dynamics (CFD) simulations of scale models with aligned guide vanes and MGVs with spectral analyses of the S curve characteristics and the pressure pulsations in the frequency and time-frequency domains at runaway conditions. The course of the S characteristic is related to the centrifugal force and the large incident angle at low flow conditions with large vortices forming between the guide vanes and the blade inlets and strong flow recirculation inside the vaneless space as the main factors that lead to the S-shaped characteristics. Preopening some of the guide vanes enables the pump-turbine to avoid the influence of the S characteristic. However, the increase of the flow during runaway destroys the flow symmetry in the runner leading to all asymmetry forces on the runner that leads to hydraulic system oscillations. The MGV technique also increases the pressure fluctuations in the draft tube and has a negative impact on stable operation of the unit.

  8. Pushability and frictional characteristics of medical instruments.

    PubMed

    Wünsche, P; Werner, C; Bloss, P

    2002-01-01

    A tensile testing equipment is combined with a torque module and a 3D force tranducer to characterize the pushability of catheter systems inside modular vessel phantoms. The modular construction of the phantom allows using two dimensional vessel shapes with different contours. Inside the phantom we put a tube or a guide catheter in which the instruments are pushed or redrawn in the presence of a liquid (water, blood, etc.) at body temperature. During pushing or redrawing we measure axial and rotational values. Additionally, friction forces and coefficients are separately determined by using a special designed friction module. First results are presented and discussed.

  9. Infrared Observations of the Solar System in Support of Large Aperture Infrared Telescope (LARITS): Calibration. Appendices

    DTIC Science & Technology

    1990-04-01

    DRIVE UNIV. OF WYOMING XXX F/24 BEAM PM TUBE CATHODE 0DWA LABORATORY BLACKUOOT LIENS N- EA F 124 CHOPPI APERATURE FILTER WHEEL CCU GUIDE PRTR LD "IRRON...V3 CATHOD HD-3 DEWAR LEN F/24 APERATURE CHOPPER IALIGNMENT FLE HE MMIRROR BLACKBODY 4 - 17.00 IN 6 OPERATOR’S MANUAL FOR THE LIGHT BEAM CHOPPER AND... oid flybys, m Of Oe 10 b llced duce important new science about of Galileo’s ma expusats, may the small, primitive planets. - new m om,. The unmAned

  10. Updates on Percutaneous Radiologic Gastrostomy/Gastrojejunostomy and Jejunostomy

    PubMed Central

    Park, Auh-Whan

    2010-01-01

    Gastrostomy placement for nutritional support for patients with inadequate oral intake has been attempted using surgical, endoscopic, and, more recently, percutaneous radiologically guided methods. Surgical gastrostomy has been superseded by both endoscopic and radiologic gastrostomy. We describe herein the indications, contraindications, patient preparations, techniques, complications, and aftercare with regard to radiologic gastrostomy. In addition, we discuss the available tube types and their perceived advantages. There remain some controversies regarding gastropexy performance and primary percutaneous gastrojejunostomy. Percutaneous jejunostomy is indicated for patients whose stomach is inaccessible for gastrostomy placement or for those who have had a previous gastrectomy. PMID:21103291

  11. Chronic recording of regenerating VIIIth nerve axons with a sieve electrode

    NASA Technical Reports Server (NTRS)

    Mensinger, A. F.; Anderson, D. J.; Buchko, C. J.; Johnson, M. A.; Martin, D. C.; Tresco, P. A.; Silver, R. B.; Highstein, S. M.

    2000-01-01

    A micromachined silicon substrate sieve electrode was implanted within transected toadfish (Opsanus tau) otolith nerves. High fidelity, single unit neural activity was recorded from seven alert and unrestrained fish 30 to 60 days after implantation. Fibrous coatings of genetically engineered bioactive protein polymers and nerve guide tubes increased the number of axons regenerating through the electrode pores when compared with controls. Sieve electrodes have potential as permanent interfaces to the nervous system and to bridge missing connections between severed or damaged nerves and muscles. Recorded impulses might also be amplified and used to control prosthetic devices.

  12. Nuclear reactor with low-level core coolant intake

    DOEpatents

    Challberg, Roy C.; Townsend, Harold E.

    1993-01-01

    A natural-circulation boiling-water reactor has skirts extending downward from control rod guide tubes to about 10 centimeters from the reactor vessel bottom. The skirts define annular channels about control rod drive housings that extend through the reactor vessel bottom. Recirculating water is forced in through the low-level entrances to these channels, sweeping bottom water into the channels in the process. The sweeping action prevents cooler water from accumulating at the bottom. This in turn minimizes thermal shock to bottom-dwelling components as would occur when accumulated cool water is swept away and suddenly replaced by warmer water.

  13. High-temperature ceramics for automobile gas turbines

    NASA Technical Reports Server (NTRS)

    Walzer, P.

    1978-01-01

    The employment of the high operational temperatures makes it necessary to use, for the construction of the turbines, ceramic materials such as silicon nitride or silicon carbide. Investigations concerning the development of turbine components made of such materials are conducted by a German automobile manufacturer and the ceramics industry. The current status of these investigations is reviewed. Flame tubes and guide-vane rings have successfully passed tests lasting 20 hours. Prototype turbine wheels have withstood the effects of peripheral speeds of 450 m/s. They also showed resistance to thermal shocks which were as high as 6-0 K/s.

  14. The Role of Aerospace Power in U.S. National Security in the Next Quarter Century: Conference Proceedings Held in Arlington, Virginia on 16 March 1993

    DTIC Science & Technology

    1993-04-16

    Kentucky long rifle is an F-15E Strike Eagle with laser -guided munitions). Aerospace power offers the ability for the United States to intervene with...glowing vacuum tubes might overshadow a single, cool microchip in their mids The Gulf War ushered in the era of the very small, very important target...precision, on making it better and better. Use the microchip as the role model. -Focus on forces and ideas which can execute rapidly, and with the minimum of

  15. Conduit grinding apparatus

    DOEpatents

    Nachbar, Henry D.; Korytkowski, Alfred S.

    1991-01-01

    A grinding apparatus for grinding the interior portion of a valve stem receiving area of a valve. The apparatus comprises a faceplate, a plurality of cams mounted to an interior face of the faceplate, a locking bolt to lock the faceplate at a predetermined position on the valve, a movable grinder and a guide tube for positioning an optical viewer proximate the area to be grinded. The apparatus can either be rotated about the valve for grinding an area of the inner diameter of a valve stem receiving area or locked at a predetermined position to grind a specific point in the receiving area.

  16. The Hitchhiker's Guide to Flow Chemistry ∥.

    PubMed

    Plutschack, Matthew B; Pieber, Bartholomäus; Gilmore, Kerry; Seeberger, Peter H

    2017-09-27

    Flow chemistry involves the use of channels or tubing to conduct a reaction in a continuous stream rather than in a flask. Flow equipment provides chemists with unique control over reaction parameters enhancing reactivity or in some cases enabling new reactions. This relatively young technology has received a remarkable amount of attention in the past decade with many reports on what can be done in flow. Until recently, however, the question, "Should we do this in flow?" has merely been an afterthought. This review introduces readers to the basic principles and fundamentals of flow chemistry and critically discusses recent flow chemistry accounts.

  17. An overview of the dynamic calibration of piezoelectric pressure transducers

    NASA Astrophysics Data System (ADS)

    Theodoro, F. R. F.; Reis, M. L. C. C.; d’ Souto, C.

    2018-03-01

    Dynamic calibration is a research area that is still under development and is of great interest to aerospace and automotive industries. This study discusses some concepts regarding dynamic measurements of pressure quantities and presents an overview of dynamic calibration of pressure transducers. Studies conducted by the Institute of Aeronautics and Space focusing on research regarding piezoelectric pressure transducer calibration in shock tube are presented. We employed the Guide to the Expression of Uncertainty and a Monte Carlo Method in the methodology. The results show that both device and methodology employed are adequate to calibrate the piezoelectric sensor.

  18. [The necessity of artificial kidney seeper in the ultrasonography-guided percutaneous nephrolithotomy: a randomized controlled study].

    PubMed

    Ye, J J; Yang, Y; Zhang, H J; Zheng, Y C; Pan, Y; Xie, H

    2018-05-01

    Objective: To investigate the necessity of artificial kidney seeper which made through inserting a ureteral tube in the ureter to the ultrasonography-guided percutaneous nephrolithotomy (PCNL). Methods: This was a randomized prospective study. Patients who conformed to the inclusion and exclusion criteria were enrolled at Department of Urology, Frist Affiliated Hospital of Wenzhou Medical University from January 2016 to May 2017. Totally 291 patients were included in the study. Patients were randomly assigned into two groups (artificial kidney seeper group and non-artificial kidney seeper group) in different kidney seeper level (5 to <10 mm, 10 to 20 mm) respectively. The artificial kidney seeper group was inserted by a ureteral cathedral, then were underwent the ultrasonography-guided PCNL in prone position. The non-artificial kidney seeper group were underwent the ultrasonography-guided PCNL in prone position directly. The t test, χ(2) test, repeated measure analysis was used to data measurement, respectively. Results: Four patients who diagnosed pyonephrosis were excluded. On the 5 to <10 mm level, fever rate (14.6% vs . 4.8%, χ(2)=5.07, P =0.03), operation time ((65.7±9.9)min vs . (50.3±7.4)min, t =11.47, P =0.00), cost ((18 327±903) yuan vs . (14 583±784) yuan, t =24.50, P =0.00) about artificial kidney seeper group and non-artificial kidney seeper group had statistical differences. And on the 10 to 20 mm level, fever rate (14.5% vs . 3.39%, χ(2)=4.53, P =0.03), operation time ((66.0±9.9)min vs . (52.4±8.9)min, t =8.30, P =0.00), cost ((16 548±537) yuan vs. (13 102±629) yuan, t =32.10, P =0.00) about artificial kidney seeper group and non-artificial kidney seeper group had statistical differences. And there were no statistical differences in the success rate of puncturing, the failures of the treatment to the stone pieces falling into the ureter and clearance rate of the stone and so on. In this study, 2 cases recovered after received transfusion and digital subtraction angiography artery embolization treatments; D-J tube was indwelled into 4 cases guiding by super smooth thread; 4 cases were finished the surgeries with the help of ureteroscopy, because the stone pieces fell into the ureter during the surgeries. And there was no patients developing septic shock, adjacent viscera injury or other serious complications. Conclusion: For seasoned doctors, there is no necessity of regularly artificial kidney seeper for PCNL when the pre-operation seeper ranging from 5 to 20 mm.

  19. A Projection Quality-Driven Tube Current Modulation Method in Cone-Beam CT for IGRT: Proof of Concept.

    PubMed

    Men, Kuo; Dai, Jianrong

    2017-12-01

    To develop a projection quality-driven tube current modulation method in cone-beam computed tomography for image-guided radiotherapy based on the prior attenuation information obtained by the planning computed tomography and then evaluate its effect on a reduction in the imaging dose. The QCKV-1 phantom with different thicknesses (0-400 mm) of solid water upon it was used to simulate different attenuation (μ). Projections were acquired with a series of tube current-exposure time product (mAs) settings, and a 2-dimensional contrast to noise ratio was analyzed for each projection to create a lookup table of mAs versus 2-dimensional contrast to noise ratio, μ. Before a patient underwent computed tomography, the maximum attenuation [Formula: see text] within the 95% range of each projection angle (θ) was estimated according to the planning computed tomography images. Then, a desired 2-dimensional contrast to noise ratio value was selected, and the mAs setting at θ was calculated with the lookup table of mAs versus 2-dimensional contrast to noise ratio,[Formula: see text]. Three-dimensional cone-beam computed tomography images were reconstructed using the projections acquired with the selected mAs. The imaging dose was evaluated with a polymethyl methacrylate dosimetry phantom in terms of volume computed tomography dose index. Image quality was analyzed using a Catphan 503 phantom with an oval body annulus and a pelvis phantom. For the Catphan 503 phantom, the cone-beam computed tomography image obtained by the projection quality-driven tube current modulation method had a similar quality to that of conventional cone-beam computed tomography . However, the proposed method could reduce the imaging dose by 16% to 33% to achieve an equivalent contrast to noise ratio value. For the pelvis phantom, the structural similarity index was 0.992 with a dose reduction of 39.7% for the projection quality-driven tube current modulation method. The proposed method could reduce the additional dose to the patient while not degrading the image quality for cone-beam computed tomography. The projection quality-driven tube current modulation method could be especially beneficial to patients who undergo cone-beam computed tomography frequently during a treatment course.

  20. NASA N+3 Subsonic Fixed Wing Silent Efficient Low-Emissions Commercial Transport (SELECT) Vehicle Study. Revision A

    NASA Technical Reports Server (NTRS)

    Bruner, Sam; Baber, Scott; Harris,Chris; Caldwell, Nicholas; Keding, Peter; Rahrig, Kyle; Pho, Luck; Wlezian, Richard

    2010-01-01

    A conceptual commercial passenger transport study was performed to define a single vehicle for entry into service in the 2030 to 2035 timeframe, meeting customer demands as well as NASA goals for improved fuel economy, NOx emissions, noise, and operability into smaller airports. A study of future market and operational scenarios was used to guide the design of an advanced tube-and-wing configuration that utilized advanced material and structural concepts, an advanced three-shaft high-bypass turbofan engine, natural laminar flow technology, and a suite of other advanced technologies. This configuration was found to meet the goals for NOx emissions, noise, and field length. A 64 percent improvement in fuel economy compared to a current state-of-the-art airliner was achieved, which fell slightly short of the desired 70 percent goal. Technology maturation plans for the technologies used in the design were developed to help guide future research and development activities.

  1. A method for improving the light intensity distribution in dental light-curing units.

    PubMed

    Arikawa, Hiroyuki; Takahashi, Hideo; Minesaki, Yoshito; Muraguchi, Kouichi; Matsuyama, Takashi; Kanie, Takahito; Ban, Seiji

    2011-01-01

    A method for improving the uniformity of the radiation light from dental light-curing units (LCUs), and the effect on the polymerization of light-activated composite resin are investigated. Quartz-tungsten halogen, plasma-arc, and light-emitting diode LCUs were used, and additional optical elements such as a mixing tube and diffusing screen were employed to reduce the inhomogeneity of the radiation light. The distribution of the light intensity from the light guide tip was measured across the guide tip, as well as the distribution of the surface hardness of the light-activated resin emitted with the LCUs. Although the additional optical elements caused 13.2-25.9% attenuation of the light intensity, the uniformity of the light intensity of the LCUs was significantly improved in the modified LCUs, and the uniformity of the surface hardness of the resin was also improved. Our results indicate that the addition of optical elements to the LCU may be a simple and effective method for reducing inhomogeneity in radiation light from the LCUs.

  2. Impact of compressibility and a guide field on Fermi acceleration during magnetic island coalescence

    NASA Astrophysics Data System (ADS)

    Montag, Peter; Egedal, Jan; Lichko, Emily; Wetherton, Blake

    2017-10-01

    Previous work has shown that Fermi acceleration can be an effective heating mechanism during magnetic island coalescence, where electrons may undergo repeated reflections as the magnetic field lines contract. This energization has the potential to account for the power-law distributions of particle energy inferred from observations of solar flares. Here, we develop a generalized framework for the analysis of Fermi acceleration that can incorporate the effects of compressibility and non-uniformity along field lines, which have commonly been neglected in previous treatments of the problem. Applying this framework to the simplified case of the uniform flux tube allows us to find both the power-law scaling of the distribution function and the rate at which the power-law behavior develops. We find that a guide magnetic field of order unity effectively suppresses the development of power-law distributions. The work was supported by NASA Grant No. NNX14AC68G, NSF GEM Grant No. 1405166, NSF Award 1404166, and NASA Award NNX15AJ73G.

  3. Core Fueling of DEMO by Direct Line Injection of High-Speed Pellets From the HFS

    DOE PAGES

    Frattolillo, Antonio; Baylor, Larry R.; Bombarda, Francesca; ...

    2018-04-17

    Pellet injection represents to date the most realistic candidate technology for core fueling of a demonstration fusion power reactor tokamak fusion reactor. Modeling of both pellet penetration and fuel deposition profiles, for different injection locations, indicates that effective core fuelling can be achieved launching pellets from the inboard high field side at speeds not less than ~ 1 km/s. Inboard pellet fueling is commonly achieved in present tokamaks, using curved guide tubes; however, this technology might be hampered at velocities ≥ 1 km/s. An innovative approach, aimed at identifying suitable inboard "direct line'' paths, to inject high-speed pellets (in themore » 3 to 4 km/s range), has recently been proposed as a potential complementary solution. The fuel deposition profiles achievable by this approach have been explored using the HPI2 simulation code. The results presented here show that there are possible geometrical schemes providing good fueling performance. The problem of neutron flux in a direct line-of-sight injection path is being investigated, though preliminary analyses indicate that, perhaps, this is not a serious problem. The identification and integration of straight injection paths suitably tilted may be a rather difficult task due to the many constraints and to interference with existing structures. The suitability of straight guide tubes to reduce the scatter cone of high-speed pellets is, therefore, of main interest. A preliminary investigation, aimed at addressing these technological issues, has recently been started. As a result, a possible implementation plan, using an existing Italian National Agency for New Technologies, Energy and Sustainable Economic Development-Oak Ridge National Laboratory facility is shortly outlined.« less

  4. AAV-CRISPR/Cas9-Mediated Depletion of VEGFR2 Blocks Angiogenesis In Vitro.

    PubMed

    Wu, Wenyi; Duan, Yajian; Ma, Gaoen; Zhou, Guohong; Park-Windhol, Cindy; D'Amore, Patricia A; Lei, Hetian

    2017-12-01

    Pathologic angiogenesis is a component of many diseases, including neovascular age-related macular degeneration, proliferation diabetic retinopathy, as well as tumor growth and metastasis. The purpose of this project was to examine whether the system of adeno-associated viral (AAV)-mediated CRISPR (clustered regularly interspaced short palindromic repeats)-associated endonuclease (Cas)9 can be used to deplete expression of VEGF receptor 2 (VEGFR2) in human vascular endothelial cells in vitro and thus suppress its downstream signaling events. The dual AAV system of CRISPR/Cas9 from Streptococcus pyogenes (AAV-SpGuide and -SpCas9) was adapted to edit genomic VEGFR2 in primary human retinal microvascular endothelial cells (HRECs). In this system, the endothelial-specific promoter for intercellular adhesion molecule 2 (ICAM2) was cloned into the dual AAV vectors of SpGuide and SpCas9 for driving expression of green fluorescence protein (GFP) and SpCas9, respectively. These two AAV vectors were applied to production of recombinant AAV serotype 5 (rAAV5), which were used to infect HRECs for depletion of VEGFR2. Protein expression was determined by Western blot; and cell proliferation, migration, as well as tube formation were examined. AAV5 effectively infected vascular endothelial cells (ECs) and retinal pigment epithelial (RPE) cells; the ICAM2 promoter drove expression of GFP and SpCas9 in HRECs, but not in RPE cells. The results showed that the rAAV5-CRISPR/Cas9 depleted VEGFR2 by 80% and completely blocked VEGF-induced activation of Akt, and proliferation, migration as well as tube formation of HRECs. AAV-CRISRP/Cas9-mediated depletion of VEGFR2 is a potential therapeutic strategy for pathologic angiogenesis.

  5. Core Fueling of DEMO by Direct Line Injection of High-Speed Pellets From the HFS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frattolillo, Antonio; Baylor, Larry R.; Bombarda, Francesca

    Pellet injection represents to date the most realistic candidate technology for core fueling of a demonstration fusion power reactor tokamak fusion reactor. Modeling of both pellet penetration and fuel deposition profiles, for different injection locations, indicates that effective core fuelling can be achieved launching pellets from the inboard high field side at speeds not less than ~ 1 km/s. Inboard pellet fueling is commonly achieved in present tokamaks, using curved guide tubes; however, this technology might be hampered at velocities ≥ 1 km/s. An innovative approach, aimed at identifying suitable inboard "direct line'' paths, to inject high-speed pellets (in themore » 3 to 4 km/s range), has recently been proposed as a potential complementary solution. The fuel deposition profiles achievable by this approach have been explored using the HPI2 simulation code. The results presented here show that there are possible geometrical schemes providing good fueling performance. The problem of neutron flux in a direct line-of-sight injection path is being investigated, though preliminary analyses indicate that, perhaps, this is not a serious problem. The identification and integration of straight injection paths suitably tilted may be a rather difficult task due to the many constraints and to interference with existing structures. The suitability of straight guide tubes to reduce the scatter cone of high-speed pellets is, therefore, of main interest. A preliminary investigation, aimed at addressing these technological issues, has recently been started. As a result, a possible implementation plan, using an existing Italian National Agency for New Technologies, Energy and Sustainable Economic Development-Oak Ridge National Laboratory facility is shortly outlined.« less

  6. NGST/XRCF Design and Build Wavescope System Pallet

    NASA Technical Reports Server (NTRS)

    Geary, Joe

    1999-01-01

    Based on the successful Wavescope demonstration at MSFC at the end of March, the decision was made by the optical testing team to purchase an upgraded Wavescope from AOA. The MSFC version would include: a higher resolution camera (1000 x 1000 pixels); a higher density lenslet array (150 x 150); updated software; and longer cables (to accommodate the remote operation of the Wavescope optical head which was resident in the Beam Guide Tube). The AOA proposal for the new instrument was received in mid-April, and delivered to MSFC in mid-July. A considerable amount of effort was expended to provide the infrastructure needed for Wavescope operation, and to incorporate it into the overall test system. This was provided by the Wavescope System Pallet (WSP) built by UAH. The WSP is illustrated. Several instruments are incorporated on this pallet. These include the: Wavescope optical head; a PDI wavefront sensor; a point spread function sensor; a Leica light-based distance measuring sensor. In addition there is a single mode fiber point source (fed from a separate source pallet) which serves both as a reference for the Wavescope and as a source point for the test mirror. There is a dual function lens which both collimates the beam from the test image point, and images the test mirror onto the lenslet array. There is a high quality Collimator which can provide a flat input wavefront directly into the Wavescope. There are also various aids such as an alignment laser, an alignment telescope, alignment sticks and apertures. The WSP was delivered to MSFC on 7/28/99. An picture shows the WSP installed in the Guide Tube at the X-Ray Calibration Facility (XRCF).

  7. Experimental investigation of the sloshing motion of the water free surface in the draft tube of a Francis turbine operating in synchronous condenser mode

    NASA Astrophysics Data System (ADS)

    Vagnoni, Elena; Favrel, Arthur; Andolfatto, Loïc; Avellan, François

    2018-06-01

    Hydropower units may be required to operate in condenser mode to supply reactive power. In this operating mode, the water level in the turbine or pump-turbine is decreased below the runner by closing the guide vanes and injecting pressurized air. While operating in condenser mode the machine experiences power losses due to several air-water interaction phenomena which cause air losses. One of such phenomena is the sloshing motion of the water free surface below the runner in the draft tube cone of a Francis turbine. The objective of the present work is to experimentally investigate the sloshing motion of the water free surface in the draft tube cone of a reduced scale physical model of a Francis turbine operating in condenser mode. Images acquisition and simultaneous pressure fluctuation measurements are performed and an image processing method is developed to investigate amplitude and frequency of the sloshing motion of the free surface. It is found that this motion is excited at the natural frequency of the water volume and corresponds to the azimuthal wavenumber m = 1 of a rotating gravity wave. The amplitude of the motion is perturbed by wave breaking and it decreases by increasing the densimetric Froude number. The sloshing frequency slightly increases with respect to the natural frequency of the water volume by increasing the densimetric Froude number. Moreover, it results that this resonant phenomenon is not related to the torque perturbation.

  8. New teaching methods in use at UC Irvine's optical engineering and instrument design programs

    NASA Astrophysics Data System (ADS)

    Silberman, Donn M.; Rowe, T. Scott; Jo, Joshua; Dimas, David

    2012-10-01

    New teaching methods reach geographically dispersed students with advances in Distance Education. Capabilities include a new "Hybrid" teaching method with an instructor in a classroom and a live WebEx simulcast for remote students. Our Distance Education Geometric and Physical Optics courses include Hands-On Optics experiments. Low cost laboratory kits have been developed and YouTube type video recordings of the instructor using these tools guide the students through their labs. A weekly "Office Hour" has been developed using WebEx and a Live Webcam the instructor uses to display his live writings from his notebook for answering students' questions.

  9. The mechanics of development: models and methods for tissue morphogenesis

    PubMed Central

    Gjorevski, Nikolce; Nelson, Celeste M.

    2011-01-01

    Embryonic development is a physical process during which masses of cells are sculpted into functional organs. The mechanical properties of tissues and the forces exerted on them serve as epigenetic regulators of morphogenesis. Understanding these mechanobiological effects in the embryo requires new experimental approaches. Here we focus on branching of the lung airways and bending of the heart tube to describe examples of mechanical and physical cues that guide cell fate decisions and organogenesis. We highlight recent technological advances to measure tissue elasticity and endogenous mechanical stresses in real time during organ development. We also discuss recent progress in manipulating forces in intact embryos. PMID:20860059

  10. Otoscopic diagnosis of otitis media.

    PubMed

    Isaacson, Glenn

    2016-12-01

    Accurate diagnosis of otitis media is important to prevent suffering and complications when infection is present, and unnecessary antibiotic use when infection is absent. The usual signs and symptoms of acute otitis media are unreliable guides in infants and young children. Similarly, middle ear effusions may present with little discomfort in older children. We therefore depend on examination of the tympanic membrane with an otoscope to make most diagnoses. This article aims to improve the accuracy of middle ear diagnosis by pneumatic otoscopy. It includes descriptions and photographs of the normal ear drum and illustrates the pathologic changes seen in acute otitis media, long-standing eustachian tube dysfunction and otitis media with effusion.

  11. Performance testing and analyses of the VSC-17 ventilated concrete cask. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKinnon, M.A.; Dodge, R.E.; Schmitt, R.C.

    1992-05-01

    This document details performance test which was conducted on a Pacific Sierra Nuclear VSC-17 ventilated concrete storage cask configured for pressurized-water reactor (PWR) spent fuel. The performance test consisted of loading the VSC-17 cask with 17 canisters of consolidated PWR spent fuel from Virginia Power`s Surry and Florida Power & Light Turkey Point reactors. Cask surface, concrete, air channel surfaces, and fuel canister guide tube temperatures were measured, as were cask surface gamma and neutron dose rates. Testing was performed with vacuum, nitrogen, and helium backfill environments in a vertical cask orientation. Data on spent fuel integrity were also obtained.

  12. Fuel assembly for nuclear reactors

    DOEpatents

    Creagan, Robert J.; Frisch, Erling

    1977-01-01

    A new and improved fuel assembly is formed to minimize the amount of parasitic structural material wherein a plurality of hollow tubular members are juxtaposed to the fuel elements of the assembly. The tubular members may serve as guide tubes for control elements and are secured to a number of longitudinally spaced grid members along the fuel assembly. The grid members include means thereon engaging each of the fuel elements to laterally position the fuel elements in a predetermined array. Openings in the bottom of each hollow member serve as a shock absorber to cushion shock transmitted to the structure when the control elements are rapidly inserted in their corresponding tubular members.

  13. Recent progress of hard x-ray imaging microscopy and microtomography at BL37XU of SPring-8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, Yoshio, E-mail: yoshio@spring8.or.jp; Takeuchi, Akihisa; Terada, Yasuko

    2016-01-28

    A hard x-ray imaging microscopy and microtomography system is now being developed at the beamline 37XU of SPring-8. In the latest improvement, a spatial resolution of about 50 nm is achieved in two-dimensional imaging at 6 keV x-ray energy using a Fresnel zone plate objective with an outermost zone width of 35 nm. In the tomographic measurement, a spatial resolution of about 100 nm is achieved at 8 keV using an x-ray guide tube condenser optic and a Fresnel zone plate objective with an outermost zone width of 50 nm.

  14. Imaging of female infertility: a pictorial guide to the hysterosalpingography, ultrasonography, and magnetic resonance imaging findings of the congenital and acquired causes of female infertility.

    PubMed

    Kaproth-Joslin, Katherine; Dogra, Vikram

    2013-11-01

    Hysterosalpingography is the gold standard in assessing the patency of the fallopian tubes, which is among the most common causes of female factor infertility, making this technique the most frequent first-choice imaging modality in the assessment of female infertility. Ultrasonography and magnetic resonance imaging are typically used for evaluation of indeterminate or complicated cases of female infertility and presurgical planning. Imaging also plays a role in the detection of the secondary causes of ovarian factor infertility, including endometriosis and polycystic ovarian syndrome. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Distortion-free diffusion MRI using an MRI-guided Tri-Cobalt 60 radiotherapy system: Sequence verification and preliminary clinical experience.

    PubMed

    Gao, Yu; Han, Fei; Zhou, Ziwu; Cao, Minsong; Kaprealian, Tania; Kamrava, Mitchell; Wang, Chenyang; Neylon, John; Low, Daniel A; Yang, Yingli; Hu, Peng

    2017-10-01

    Monitoring tumor response during the course of treatment and adaptively modifying treatment plan based on tumor biological feedback may represent a new paradigm for radiotherapy. Diffusion MRI has shown great promises in assessing and predicting tumor response to radiotherapy. However, the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) technique suffers from limited resolution, severe distortion, and possibly inaccurate ADC at low field strength. The purpose of this work was to develop a reliable, accurate and distortion-free diffusion MRI technique that is practicable for longitudinal tumor response evaluation and adaptive radiotherapy on a 0.35 T MRI-guided radiotherapy system. A diffusion-prepared turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging sequence on a 0.35 T MRI-guided radiotherapy system (ViewRay). A spatial integrity phantom was used to quantitate and compare the geometric accuracy of the two diffusion sequences for three orthogonal orientations. The apparent diffusion coefficient (ADC) accuracy was evaluated on a diffusion phantom under both 0 °C and room temperature to cover a diffusivity range between 0.40 × 10 -3 and 2.10 × 10 -3 mm 2 /s. Ten room temperature measurements repeated on five different days were conducted to assess the ADC reproducibility of DP-TSE. Two glioblastoma (GBM) and six sarcoma patients were included to examine the in vivo feasibility. The target registration error (TRE) was calculated to quantitate the geometric accuracy where structural CT or MR images were co-registered to the diffusion images as references. ADC maps from DP-TSE and DW-ssEPI were calculated and compared. A tube phantom was placed next to patients not treated on ViewRay, and ADCs of this reference tube were also compared. The proposed DP-TSE passed the spatial integrity test (< 1 mm within 100 mm radius and < 2 mm within 175 mm radius) under the three orthogonal orientations. The detected errors were 0.474 ± 0.355 mm, 0.475 ± 0.287 mm, and 0.546 ± 0.336 mm in the axial, coronal, and sagittal plane. DW-ssEPI, however, failed the tests due to severe distortion and low signal intensity. Noise correction must be performed for the DW-ssEPI to avoid ADC quantitation errors, whereas it is optional for DP-TSE. At 0 °C, the two sequences provided accurate quantitation with < 3% variation with the reference. In the room temperature study, discrepancies between ADCs from DP-TSE and the reference were within 4%, but could be as high as 8% for DW-ssEPI after the noise correction. Excellent ADC reproducibility with a coefficient of variation < 5% was observed among the 10 measurements of DP-TSE, indicating desirable robustness for ADC-based tumor response assessment. In vivo TRE in DP-TSE was less than 1.6 mm overall, whereas it could be greater than 12 mm in DW-ssEPI. For GBM patients, the CSF and brain tissue ADCs from DP-TSE were within the ranges found in literature. ADC differences between the two techniques were within 8% among the six sarcoma patients. For the reference tube that had a relatively low diffusivity, the two diffusion sequences provided matched measurements. A diffusion technique with excellent geometric fidelity, accurate, and reproducible ADC measurement was demonstrated for longitudinal tumor response assessment using a low-field MRI-guided radiotherapy system. © 2017 American Association of Physicists in Medicine.

  16. Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients.

    PubMed

    Hanauer, Matthieu; Perentes, Jean Yannis; Krueger, Thorsten; Ris, Hans-Beat; Bize, Pierre; Schmidt, Sabine; Gonzalez, Michel

    2016-01-16

    Video-assisted thoracic surgery (VATS) is currently performed to diagnose and treat solitary pulmonary nodules (SPN). However, the intra-operative identification of deep nodules can be challenging with VATS as the lung is difficult to palpate. The aim of the study was to report the utility and the results of pre-operative computed tomography (CT)-guided hook wire localization of SPN. All records of the patients undergoing CT-guided hook wire localization prior to VATS resection for SPN between 2002 and 2013 were reviewed. The efficacy in localizing the nodule, hook wire complications, necessity to convert VATS to thoracotomy and the histology of SPN are reported. One hundred eighty-one patients (90 females, mean age 63 y, range 28-82 y) underwent 187 pulmonary resections after CT-guided hook wire localization. The mean SPN diameter was 10.3 mm (range: 4-29 mm). The mean distance of the lesion from the pleural surface was 11.6 mm (range: 0-45 mm). The mean time interval from hook wire insertion to VATS resection was 224 min (range 54-622 min). Hook wire complications included pneumothorax requiring chest tube drainage in 4 patients (2.1%) and mild parenchymal haemorrhage in 11 (5.9%) patients. Migration of the hook wire occurred in 7 patients (3.7%) although it did not affect the success of VATS resection (nodule location guided by the lung puncture site). Three patients underwent additional wedge resection by VATS during the same procedure because no lesion was identified in the surgical specimen. Conversion thoracotomy was required in 13 patients (7 %) for centrally localized lesions (6 patients) and pleural adhesions (7 patients). The mean operative time was 60 min (range 18-135 min). Pathological examination revealed a malignant lesion in 107 patients (59 %). The diagnostic yield was 98.3 %. VATS resection for SPN after CT-guided hook wire localization for SPN is safe and allows for proper diagnosis with a low thoracotomy conversion rate.

  17. Focal spot size reduction using asymmetric collimation to enable reduced anode angles with a conventional angiographic x-ray tube for use with high resolution detectors.

    PubMed

    Russ, M; Shankar, A; Setlur Nagesh, S V; Ionita, C N; Bednarek, D R; Rudin, S

    2017-02-11

    The high-resolution requirements for neuro-endovascular image-guided interventions (EIGIs) necessitate the use of a small focal-spot size; however, the maximum tube output limits for such small focal-spot sizes may not enable sufficient x-ray fluence after attenuation through the human head to support the desired image quality. This may necessitate the use of a larger focal spot, thus contributing to the overall reduction in resolution. A method for creating a higher-output small effective focal spot based on the line-focus principle has been demonstrated and characterized. By tilting the C-arm gantry, the anode-side of the x-ray field-of-view is accessible using a detector placed off-axis. This tilted central axis diminishes the resultant focal spot size in the anode-cathode direction by the tangent of the effective anode angle, allowing a medium focal spot to be used in place of a small focal spot with minimal losses in resolution but with increased tube output. Images were acquired of two different objects at the central axis, and with the C-arm tilted away from the central axis at 1° increments from 0°-7°. With standard collimation settings, only 6° was accessible, but using asymmetric extended collimation a maximum of 7° was accessed for enhanced comparisons. All objects were positioned perpendicular to the anode-cathode direction and images were compared qualitatively. The increasing advantage of the off-axis focal spots was quantitatively evidenced at each subsequent angle using the Generalized Measured-Relative Object Detectability metric (GM-ROD). This anode-tilt method is a simple and robust way of increasing tube output for a small field-of-view detector without diminishing the overall apparent resolution for neuro-EIGIs.

  18. Focal spot size reduction using asymmetric collimation to enable reduced anode angles with a conventional angiographic x-ray tube for use with high resolution detectors

    NASA Astrophysics Data System (ADS)

    Russ, M.; Shankar, A.; Setlur Nagesh, S. V.; Ionita, C. N.; Bednarek, D. R.; Rudin, S.

    2017-03-01

    The high-resolution requirements for neuro-endovascular image-guided interventions (EIGIs) necessitate the use of a small focal-spot size; however, the maximum tube output limits for such small focal-spot sizes may not enable sufficient x-ray fluence after attenuation through the human head to support the desired image quality. This may necessitate the use of a larger focal spot, thus contributing to the overall reduction in resolution. A method for creating a higher-output small effective focal spot based on the line-focus principle has been demonstrated and characterized. By tilting the C-arm gantry, the anode-side of the x-ray field-of-view is accessible using a detector placed off-axis. This tilted central axis diminishes the resultant focal spot size in the anode-cathode direction by the tangent of the effective anode angle, allowing a medium focal spot to be used in place of a small focal spot with minimal losses in resolution but with increased tube output. Images were acquired of two different objects at the central axis, and with the C-arm tilted away from the central axis at 1° increments from 0°-7°. With standard collimation settings, only 6° was accessible, but using asymmetric extended collimation a maximum of 7° was accessed for enhanced comparisons. All objects were positioned perpendicular to the anode-cathode direction and images were compared qualitatively. The increasing advantage of the off-axis focal spots was quantitatively evidenced at each subsequent angle using the Generalized Measured-Relative Object Detectability metric (GM-ROD). This anode-tilt method is a simple and robust way of increasing tube output for a small field-of-view detector without diminishing the overall apparent resolution for neuro-EIGIs.

  19. Characteristics of chiral plasma plumes generated in the absence of external magnetic field

    NASA Astrophysics Data System (ADS)

    Nie, LanLan; Liu, FengWu; Zhou, XinCai; Lu, XinPei; Xian, YuBin

    2018-05-01

    A chiral plasma plume has recently been generated inside a dielectric tube without the use of an external magnetic field. In this paper, we seek to further study the key properties of such a chiral plume to improve our understanding of how this interesting structure is generated and controlled. The chiral plume is generated by externally mounting a stainless steel helical coil or a ring onto the dielectric tube. By changing the pitch of the helical coil, the pitch of the plasma plume can be controlled, with the shape of the plume following the shape of the helical coil. The addition of the helical coil significantly expands the range of parameters under which the chiral plasma plume appears. When the frequency of the applied voltage increases, additional stable discharge channels appear between the adjacent helices. The addition of two helical coils results in the formation of two chiral plasma plumes, which follow the shape of the helical coils. When a metal ring is placed on the outside of the tube, there is no chiral plasma plume between the high voltage electrode and the ring; however, a chiral plasma plume appears on the right side of the ring if the distance between the ring and the high voltage electrode is small. These findings suggest that the chiral plasma can be effectively modulated and guided using an externally mounted helical coil, which acts as the floating/actual ground to reduce the impedance of the discharge and as such contributes to the emergence of the chiral plasma plume behavior.

  20. What Is the Evidence for Use of a Supplemental Feeding Tube Device as an Alternative Supplemental Feeding Method for Breastfed Infants?

    PubMed

    Penny, Frances; Judge, Michelle; Brownell, Elizabeth; McGrath, Jacqueline M

    2018-02-01

    According to the Healthy People 2020 goals, the sustainability of breastfeeding duration rates within the United States has not been achieved. To increase these rates, it is important that women with breastfeeding difficulties receive the support needed to continue breastfeeding. When supplementation occurs, it is essential that the breastfeeding relationship be preserved. Various methods of supplementation are often recommended including use of the supplemental feeding tube device (SFTD). The question guiding this brief is "What evidence exists to support the use of an SFTD as a method of supplementation for breastfed infants?" The PubMed and CINAHL databases were queried for original research published in English from 1990 through July 2016. Search terms included "supplemental feeding tube," "breastfeeding," "term infants," "premature infants," "Supplemental Nursing System," "Lact-aid," and "supply line." Very limited research exists on the use of SFTDs as a method of supplementation for breastfed infants; however, existing research suggests that an SFTD may be useful as a supplementation method for breastfed infants. High-quality research is needed to evaluate the efficacy of using an SFTD for supporting exclusive and all breastfeeding rates. Nurses and providers need to be educated and trained in the use of SFTDs as well as all supplemental feeding methods. Information on efficacy and SFTD use should also be included in policies related to breastfeeding and human milk use. Further research should determine best methods of supplementation for breastfed infants and should examine differences in breastfeeding rates when using the SFTD for supplementation.

  1. Silicon carbide composite for light water reactor fuel assembly applications

    NASA Astrophysics Data System (ADS)

    Yueh, Ken; Terrani, Kurt A.

    2014-05-01

    The feasibility of using SiCf-SiCm composites in light water reactor (LWR) fuel designs was evaluated. The evaluation was motivated by the desire to improve fuel performance under normal and accident conditions. The Fukushima accident once again highlighted the need for improved fuel materials that can maintain fuel integrity to higher temperatures for longer periods of time. The review identified many benefits as well as issues in using the material. Issues perceived as presenting the biggest challenges to the concept were identified to be flux gradient induced differential volumetric swelling, fragmentation and thermal shock resistance. The oxidation of silicon and its release into the coolant as silica has been identified as an issue because existing plant systems have limited ability for its removal. Detailed evaluation using available literature data and testing as part of this evaluation effort have eliminated most of the major concerns. The evaluation identified Boiling Water Reactor (BWR) channel, BWR fuel water tube, and Pressurized Water Reactor (PWR) guide tube as feasible applications for SiC composite. A program has been initiated to resolve some of the remaining issues and to generate physical property data to support the design of commercial fuel components.

  2. Percutaneous cecostomy in the management of organic fecal incontinence in children

    PubMed Central

    Donkol, Ragab Hani; Al-Nammi, Ahmed

    2010-01-01

    AIM: To assess the effectiveness and safety of imaging-guided percutaneous cecostomy in the management of pediatric patients with organic fecal incontinence. METHODS: Twenty three cecostomies were performed on 21 children with organic fecal incontinence (13 males, 8 females), aged from 5 to 16 years (mean 9.5 years). Thirteen patients had neurogenic fecal incontinence and 8 patients had anorectal anomalies. Procedures were performed under general anesthesia and fluoroscopic guidance. Effectiveness and complication data were obtained for at least 1 year after the procedure. RESULTS: Cecostomy was successful in 20 patients (primary technical success rate 95%). Cecostomy failed in one patient due to tube breakage (secondary technical success rate 100%). The tubes were in situ for an average of 18 mo (range 12-23 mo). Eighteen patients (87%) expressed satisfaction with the procedures. Resolution of soiling was achieved in all patients with neurogenic fecal incontinence (100%) and in 5 of 8 patients with anorectal anomalies (62.5%). Eleven patients (52%) experienced minor problems. No major complications were noted. CONCLUSION: Percutaneous cecostomy improves the quality of life in children with organic fecal incontinence. A satisfactory outcome is more prevalent in patients with neurogenic fecal incontinence than anorectal anomalies. PMID:21225001

  3. Guided flows in coronal magnetic flux tubes

    NASA Astrophysics Data System (ADS)

    Petralia, A.; Reale, F.; Testa, P.

    2018-01-01

    Context. There is evidence that coronal plasma flows break down into fragments and become laminar. Aims: We investigate this effect by modelling flows confined along magnetic channels. Methods: We consider a full magnetohydrodynamic (MHD) model of a solar atmosphere box with a dipole magnetic field. We compare the propagation of a cylindrical flow perfectly aligned with the field to that of another flow with a slight misalignment. We assume a flow speed of 200 km s-1 and an ambient magnetic field of 30 G. Results: We find that although the aligned flow maintains its cylindrical symmetry while it travels along the magnetic tube, the misaligned one is rapidly squashed on one side, becoming laminar and eventually fragmented because of the interaction and back-reaction of the magnetic field. This model could explain an observation made by the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory of erupted fragments that fall back onto the solar surface as thin and elongated strands and end up in a hedge-like configuration. Conclusions: The initial alignment of plasma flow plays an important role in determining the possible laminar structure and fragmentation of flows while they travel along magnetic channels. Movies are available in electronic form at http://www.aanda.org

  4. The structure and energy balance of cool star atmospheres

    NASA Technical Reports Server (NTRS)

    Linsky, J. L.

    1982-01-01

    The atmospheric structure and energy balance phenomena associated with magnetic fields in the Sun are reviewed and it is shown that similar phenomena occur in cool stars. The evidence for the weakening or disappearance of transition regions and coronae is discussed together with the appearance of extended cool chromospheres with large mass loss, near V-R = 0.80 in the H-R diagram. Like the solar atmosphere, these atmospheres are not homogeneous and there is considerable evidence for plage regions with bright TR emission lines that overlie dark (presumably magnetic) star spots. The IUE observations are providing important information on the energy balance in these atmospheres that should guide theoretical calculations of the nonradiative heating rate. Recent high dispersion spectra are providing unique information concerning which components of close binary systems are the dominant contributors to the observed emission. A recent unanticipated discovery is that the transition lines are redshifted (an antiwind) in DRa (G2 Ib) and perhaps other stars. Finally, the G and K giants and supergiants are classified into three groups depending on whether their atmospheres are dominated by closed magnetic flux tubes, open field geometries, or a predominately open geometry with a few closed flux tubes embedded.

  5. Confluence or independence of microwave plasma bullets in atmospheric argon plasma jet plumes

    NASA Astrophysics Data System (ADS)

    Li, Ping; Chen, Zhaoquan; Mu, Haibao; Xu, Guimin; Yao, Congwei; Sun, Anbang; Zhou, Yuming; Zhang, Guanjun

    2018-03-01

    Plasma bullet is the formation and propagation of a guided ionization wave (streamer), normally generated in atmospheric pressure plasma jet (APPJ). In most cases, only an ionization front produces in a dielectric tube. The present study shows that two or three ionization fronts can be generated in a single quartz tube by using a microwave coaxial resonator. The argon APPJ plumes with a maximum length of 170 mm can be driven by continuous microwaves or microwave pulses. When the input power is higher than 90 W, two or three ionization fronts propagate independently at first; thereafter, they confluence to form a central plasma jet plume. On the other hand, the plasma bullets move independently as the lower input power is applied. For pulsed microwave discharges, the discharge images captured by a fast camera show the ionization process in detail. Another interesting finding is that the strongest lightening plasma jet plumes always appear at the shrinking phase. Both the discharge images and electromagnetic simulations suggest that the confluence or independent propagation of plasma bullets is resonantly excited by the local enhanced electric fields, in terms of wave modes of traveling surface plasmon polaritons.

  6. Hypersonic nozzle design

    NASA Technical Reports Server (NTRS)

    Griffith, Wayland C.

    1989-01-01

    Possible experimental facilities appropriate to a university environment that could make meaningful contributions to the solution of problems in hypersonic aerodynamics are investigated. Needs for the National Aerospace Plane and interplanetary flights with atmospheric aerobraking are used to scope the problem. Relevant events of the past two decades in universities and at the national laboratories are examined for their implications regarding both problems and prospects. Most striking is the emergence of computational fluid dynamics, which is viewed here as an equal partner with laboratory experimentation and flight test in relating theory with reality. Also significant are major advances in instrumentation and data processing methods, especially optical techniques. The direction of the study was guided by the concept of a companion program, i.e., the university effort should complement a major area of endeavor at NASA-Langley. Through this, both faculty and student participants gain a natural and effective working relationship. Existing and proposed major hypersonic aerodynamic facilities in industry and at the national laboratories are examined by type; hypersonic wind tunnels, arc-heated tunnels, shock tubes and tunnels, and ballistic ranges. Of these, the free piston tunnel and shock tube/tunnel are most appropriate for a university.

  7. CT-Guided, Ethanol Sympatholysis for Primary Axillary–Palmar Hyperhidrosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsitskari, Maria, E-mail: mariadote@hotmail.com; Friehs, Gerhard, E-mail: gerhardf@amc.com.cy; Zerris, Vassilis, E-mail: vassilisz@amc.com.cy

    PurposePrimary hyperhidrosis is an excessive sweating due to an overactive sympathetic system. Our objective was to test the feasibility and provide early data on the safety/efficacy of CT-guided sympatholysis, for primary hyperhidrosis.Materials and MethodsNine consecutive patients with axillary–palmar hyperhidrosis were treated between 2013 and 2015. CT-guided sympathetic block was performed in the outpatients at T-2, T-3, and T-4, bilaterally using alcohol under local anesthesia. Immediate postprocedure CT was obtained to assess the complications as per Common Terminology Criteria for Adverse Events, version 4. Technical success and clinical success were recorded. Primary and secondary efficacy were assessed by phone and clinicalmore » visits; mean follow-up was 12 months (6–26 months). Descriptive statistics was used to report the outcomes.ResultsOne procedure was aborted due to eyelid ptosis after lidocaine injection. All other eight patients (5:3, F:M) (median age 32) had immediate cessation of sweating. Two major complications (pneumothorax, one requiring a chest tube) occurred. Two patients recurred with unilateral and one with bilateral symptoms. One of the unilateral recurrence and the bilateral recurrence patients was retreated successfully. Median follow-up was 1 year. No cases of Horner’s or compensatory hyperhidrosis were observed.ConclusionsCT-guided EtOH sympatholysis for axillary/palmar primary hyperhidrosis is feasible. Technical failure rate was 11 %. Primary and secondary efficacy are 75 and 94 %, respectively, to a median follow-up of 1 year. Risk profile appears favorable. Despite a small sample size, results confirm feasibility and encourage a larger study.« less

  8. CT-Guided, Ethanol Sympatholysis for Primary Axillary-Palmar Hyperhidrosis.

    PubMed

    Tsitskari, Maria; Friehs, Gerhard; Zerris, Vassilis; Georgiades, Christos

    2016-12-01

    Primary hyperhidrosis is an excessive sweating due to an overactive sympathetic system. Our objective was to test the feasibility and provide early data on the safety/efficacy of CT-guided sympatholysis, for primary hyperhidrosis. Nine consecutive patients with axillary-palmar hyperhidrosis were treated between 2013 and 2015. CT-guided sympathetic block was performed in the outpatients at T-2, T-3, and T-4, bilaterally using alcohol under local anesthesia. Immediate postprocedure CT was obtained to assess the complications as per Common Terminology Criteria for Adverse Events, version 4. Technical success and clinical success were recorded. Primary and secondary efficacy were assessed by phone and clinical visits; mean follow-up was 12 months (6-26 months). Descriptive statistics was used to report the outcomes. One procedure was aborted due to eyelid ptosis after lidocaine injection. All other eight patients (5:3, F:M) (median age 32) had immediate cessation of sweating. Two major complications (pneumothorax, one requiring a chest tube) occurred. Two patients recurred with unilateral and one with bilateral symptoms. One of the unilateral recurrence and the bilateral recurrence patients was retreated successfully. Median follow-up was 1 year. No cases of Horner's or compensatory hyperhidrosis were observed. CT-guided EtOH sympatholysis for axillary/palmar primary hyperhidrosis is feasible. Technical failure rate was 11 %. Primary and secondary efficacy are 75 and 94 %, respectively, to a median follow-up of 1 year. Risk profile appears favorable. Despite a small sample size, results confirm feasibility and encourage a larger study.

  9. Energy release and transfer in guide field reconnection

    NASA Astrophysics Data System (ADS)

    Birn, J.; Hesse, M.

    2010-01-01

    Properties of energy release and transfer by magnetic reconnection in the presence of a guide field are investigated on the basis of 2.5-dimensional magnetohydrodynamic (MHD) and particle-in-cell (PIC) simulations. Two initial configurations are considered: a plane current sheet with a uniform guide field of 80% of the reconnecting magnetic field component and a force-free current sheet in which the magnetic field strength is constant but the field direction rotates by 180° through the current sheet. The onset of reconnection is stimulated by localized, temporally limited compression. Both MHD and PIC simulations consistently show that the outgoing energy fluxes are dominated by (redirected) Poynting flux and enthalpy flux, whereas bulk kinetic energy flux and heat flux (in the PIC simulation) are small. The Poynting flux is mainly associated with the magnetic energy of the guide field which is carried from inflow to outflow without much alteration. The conversion of annihilated magnetic energy to enthalpy flux (that is, thermal energy) stems mainly from the fact that the outflow occurs into a closed field region governed by approximate force balance between Lorentz and pressure gradient forces. Therefore, the energy converted from magnetic to kinetic energy by Lorentz force acceleration becomes immediately transferred to thermal energy by the work done by the pressure gradient force. Strong similarities between late stages of MHD and PIC simulations result from the fact that conservation of mass and entropy content and footpoint displacement of magnetic flux tubes, imposed in MHD, are also approximately satisfied in the PIC simulations.

  10. Image-guided drainage versus antibiotic-only treatment of pelvic abscesses: short-term and long-term outcomes.

    PubMed

    To, Justin; Aldape, Diana; Frost, Andrei; Goldberg, Gary L; Levie, Mark; Chudnoff, Scott

    2014-10-01

    To determine the efficacy of image-guided drainage versus antibiotic-only treatment of pelvic abscesses. Retrospective cohort analysis. An academic, inner-city medical center. Women ages 11-49, admitted between 1998 and 2008 with ICD9 code 614.x (inflammatory diseases of ovary, fallopian tube, pelvic cellular tissue, and peritoneum). Medical records search, chart review, and phone survey. Surgical intervention. We identified 6,151 initial patients, of whom 240 patients met inclusion criteria. Of the included patients, 199 women received antibiotic-only treatment, and 41 received additional image-guided drainage. There was no statistically significant difference between the two groups in terms of age, body mass index, parity, incidence of diabetes, obesity, endometriosis, or history of sexually transmitted infection excluding human immunodeficiency virus (HIV). Abscesses in the drainage cohort were noted to be larger in dimension (5.9 cm vs. 8.5 cm); 16.1% of patients who received antibiotics alone required surgical intervention versus only 2.4% of the drainage cohort. Patients who received drainage had longer hospital stays, but the time from treatment to discharge was similar in both groups (7.4 days vs. 6.7 days). We successfully contacted 150 patients, and the differences in long-term pregnancy outcomes, pain, or infertility were not statistically significant. Patients who received antibiotics alone were more likely to require further surgical intervention when compared with patients who additionally received image-guided drainage. There were no observable long-term differences. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  11. Diagnostic Accuracy of MRI-guided Percutaneous Transthoracic Needle Biopsy of Solitary Pulmonary Nodules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Shangang, E-mail: 1198685580@qq.com; Li, Chengli, E-mail: chenglilichina@yeah.net; Yu, Xuejuan, E-mail: yuxuejuan2011@126.com

    2015-04-15

    ObjectiveThe purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs).MethodsRetrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The final diagnosis was established by surgical pathology of the nodule or clinical and imaging follow-up. Pneumothorax rate and diagnostic accuracy were compared between two groups according to nodule diameter (≤2 vs. >2 cm) using χ{sup 2} chest and Fisher’s exact test, respectively.ResultsThe success rate of single puncture was 95.6 %. Twelve (17.4 %) patients had pneumothorax, with 1 (1.4 %) requiring chestmore » tube insertion. Mild hemoptysis occurred in 7 (7.2 %) patients. All of the sample material was sufficient for histological diagnostic evaluation. Pathological analysis of biopsy specimens showed 46 malignant, 22 benign, and 1 nondiagnostic nodule. The final diagnoses were 49 malignant nodules and 20 benign nodules basing on postoperative histopathology and clinical follow-up data. One nondiagnostic sample was excluded from calculating diagnostic performance. A sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in diagnosing SPNs were 95.8, 100, 97.0, 100, and 90.9 %, respectively. Pneumothorax rate, diagnostic sensitivity, and accuracy were not significantly different between the two groups (P > 0.05).ConclusionsMRI-guided PTNB is safe, feasible, and high accurate diagnostic technique for pathologic diagnosis of pulmonary nodules.« less

  12. Arterial waveguide model for shear wave elastography: implementation and in vitro validation

    NASA Astrophysics Data System (ADS)

    Vaziri Astaneh, Ali; Urban, Matthew W.; Aquino, Wilkins; Greenleaf, James F.; Guddati, Murthy N.

    2017-07-01

    Arterial stiffness is found to be an early indicator of many cardiovascular diseases. Among various techniques, shear wave elastography has emerged as a promising tool for estimating local arterial stiffness through the observed dispersion of guided waves. In this paper, we develop efficient models for the computational simulation of guided wave dispersion in arterial walls. The models are capable of considering fluid-loaded tubes, immersed in fluid or embedded in a solid, which are encountered in in vitro/ex vivo, and in vivo experiments. The proposed methods are based on judiciously combining Fourier transformation and finite element discretization, leading to a significant reduction in computational cost while fully capturing complex 3D wave propagation. The developed methods are implemented in open-source code, and verified by comparing them with significantly more expensive, fully 3D finite element models. We also validate the models using the shear wave elastography of tissue-mimicking phantoms. The computational efficiency of the developed methods indicates the possibility of being able to estimate arterial stiffness in real time, which would be beneficial in clinical settings.

  13. Oesophageal stent placement to treat a massive iatrogenic duodenal defect after laparoscopic cholecystectomy.

    PubMed

    Greenbaum, Alissa; Parasher, Gulshan; Demarest, Gerald; Auyang, Edward

    2017-05-05

    Iatrogenic duodenal injury occurring during laparoscopic cholecystectomy (LC) is managed surgically, though rarely a large, persistent fistula is refractory to surgical interventions. We present the case of a 40-year-old woman transferred to our centre following elective LC for a reported perforated duodenal ulcer. An uncontained leak was found to originate from a 1.5 cm duodenal defect, with no evidence of ulceration. A duodenostomy tube was placed. One month after abdominal closure, the patient continued to have a persistent, large duodenal fistula. A through-the-scope covered oesophageal stent was placed under endoscopic and fluoroscopic guidance. Five weeks later, it was successfully retrieved and no subsequent extravasation of contrast from the duodenum was noted. Unrecognised iatrogenic duodenal injuries sustained during LC can be catastrophic. In cases of massive duodenal defects and high-output biliary fistula uncontrolled after surgical intervention, endoscopic-guided and fluoroscopic-guided placement of a fully covered oesophageal stent may be lifesaving. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Spontaneous wrinkling in azlactone-based functional polymer thin films in 2D and 3D geometries for guided nanopatterning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramanathan, Muruganathan; Lokitz, Bradley S.; Messman, Jamie M.

    We report a simple, one step process for developing wrinkling patterns in azlactone-based polymer thin films and brushes in 2D and 3D surfaces. The polymer used in this work wrinkles spontaneously upon deposition and solidification on a substrate without applying any external strain to the substrate, with the mode of deposition defining the direction of the wrinkles. Wrinkle formation is shown to occur on a variety of substrates over large areas. We also find that a very thin brush-like layer of an azlactone-containing block copolymer also exhibits wrinkled topology. Given the spontaneity and versatility of wrinkle formation, we further demonstratemore » two proofs-of-concept, i) that these periodic wrinkled structures are not limited to planar surfaces, but are also developed in complex geometries including tubes, cones and other 3D structures; and ii) that this one-step wrinkling process can be used to guide the deposition of metal nanoparticles and quantum dots, creating a periodic, nanopatterned film.« less

  15. Effects of line fiducial parameters and beamforming on ultrasound calibration

    PubMed Central

    Ameri, Golafsoun; Baxter, John S. H.; McLeod, A. Jonathan; Peters, Terry M.; Chen, Elvis C. S.

    2017-01-01

    Abstract. Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom material and geometry on US calibration. It was shown that the FLE was reduced by 29% with synthetic transmit aperture imaging compared with conventional B-mode imaging in a Z-bar calibration, resulting in a 10% reduction of calibration error. In addition, an evaluation of a variety of calibration phantoms with different geometrical and material properties was performed. The phantoms included braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. It was shown that these properties have a significant effect on calibration error, which is a variable based on US beamforming techniques. These results would have important implications for calibration procedures and their feasibility in the context of image-guided procedures. PMID:28331886

  16. Effects of line fiducial parameters and beamforming on ultrasound calibration.

    PubMed

    Ameri, Golafsoun; Baxter, John S H; McLeod, A Jonathan; Peters, Terry M; Chen, Elvis C S

    2017-01-01

    Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom material and geometry on US calibration. It was shown that the FLE was reduced by 29% with synthetic transmit aperture imaging compared with conventional B-mode imaging in a Z-bar calibration, resulting in a 10% reduction of calibration error. In addition, an evaluation of a variety of calibration phantoms with different geometrical and material properties was performed. The phantoms included braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. It was shown that these properties have a significant effect on calibration error, which is a variable based on US beamforming techniques. These results would have important implications for calibration procedures and their feasibility in the context of image-guided procedures.

  17. How to get students to love (or not hate) MATLAB and programming

    NASA Astrophysics Data System (ADS)

    Reckinger, Shanon; Reckinger, Scott

    2014-11-01

    An effective programming course geared toward engineering students requires the utilization of modern teaching philosophies. A newly designed course that focuses on programming in MATLAB involves flipping the classroom and integrating various active teaching techniques. Vital aspects of the new course design include: lengthening in-class contact hours, Process-Oriented Guided Inquiry Learning (POGIL) method worksheets (self-guided instruction), student created video content posted on YouTube, clicker questions (used in class to practice reading and debugging code), programming exams that don't require computers, integrating oral exams into the classroom, fostering an environment for formal and informal peer learning, and designing in a broader theme to tie together assignments. However, possibly the most important piece to this programming course puzzle: the instructor needs to be able to find programming mistakes very fast and then lead individuals and groups through the steps to find their mistakes themselves. The effectiveness of the new course design is demonstrated through pre- and post- concept exam results and student evaluation feedback. Students reported that the course was challenging and required a lot of effort, but left largely positive feedback.

  18. The Upgrade of the Neutron Induced Positron Source NEPOMUC

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, C.; Ceeh, H.; Gigl, T.; Lippert, F.; Piochacz, C.; Pikart, P.; Reiner, M.; Weber, J.; Zimnik, S.

    2013-06-01

    In summer 2012, the new NEutron induced POsitron Source MUniCh (NEPOMUC) was installed and put into operation at the research reactor FRM II. At NEPOMUC upgrade 80% 113Cd enriched Cd is used as neutron-gamma converter in order to ensure an operation time of 25 years. A structure of Pt foils inside the beam tube generates positrons by pair production. Moderated positrons leaving the Pt front foil are electrically extracted and magnetically guided to the outside of the reactor pool. The whole design, including Pt-foils, the electric lenses and the magnetic fields, has been improved in order to enhance both the intensity and the brightness of the positron beam. After adjusting the potentials and the magnetic guide and compensation fields an intensity of about 3·109 moderated positrons per second is expected. During the first start-up, the measured temperatures of about 90°C ensure a reliable operation of the positron source. Within this contribution the features and the status of NEPOMUC upgrade are elucidated. In addition, an overview of recent positron beam experiments and current developments at the spectrometers is given.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borot de Battisti, Maxence, E-mail: M.E.P.Borot@um

    Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensorsmore » each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position measurements was equal to 0.79 mm(0.37 mm). The update rate and latency of the FBG-based needle position measurement were 100 and 300 ms, respectively. Conclusions: The FBG-based needle tracking procedure proposed in this paper is able to determine the position of the complete needle, under MR-imaging, with better accuracy and precision, higher update rate, and lower latency compared to current MR-based needle localization methods. This system would be eligible for MR-guided brachytherapy, in particular, for an improved needle guidance and reconstruction.« less

  20. Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy.

    PubMed

    Andersen, Claus E; Nielsen, Søren Kynde; Lindegaard, Jacob Christian; Tanderup, Kari

    2009-11-01

    The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with 192Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) delivered by intracavitary/interstitial applicators (tandem-ring systems and/or needles). For each patient, one or two dosimetry probes were placed directly in or close to the tumor region using stainless steel or titanium needles. Each dosimeter probe consisted of a small aluminum oxide crystal attached to an optical fiber cable (1 mm outer diameter) that could guide radioluminescence (RL) and optically stimulated luminescence (OSL) from the crystal to special readout instrumentation. Positioning uncertainty and hypothetical dose-delivery errors (interchanged guide tubes or applicator movements from +/-5 to +/-15 mm) were simulated in software in order to assess the ability of the system to detect errors. For three of the patients, the authors found no significant differences (P>0.01) for comparisons between in vivo measurements and calculated reference values at the level of dose per dwell position, dose per applicator, or total dose per pulse. The standard deviations of the dose per pulse were less than 3%, indicating a stable dose delivery and a highly stable geometry of applicators and dosimeter probes during the treatments. For the two other patients, the authors noted significant deviations for three individual pulses and for one dosimeter probe. These deviations could have been due to applicator movement during the treatment and one incorrectly positioned dosimeter probe, respectively. Computer simulations showed that the likelihood of detecting a pair of interchanged guide tubes increased by a factor of 10 or more for the considered patients when going from integrating to time-resolved dose verification. The likelihood of detecting a +/-15 mm displacement error increased by a factor of 1.5 or more. In vivo fiber-coupled RL/OSL dosimetry based on detectors placed in standard brachytherapy needles was demonstrated. The time-resolved dose-rate measurements were found to provide a good way to visualize the progression and stability of PDR brachytherapy dose delivery, and time-resolved dose-rate measurements provided an increased sensitivity for detection of dose-delivery errors compared with time-integrated dosimetry.

  1. A novel technique of concurrent esophagoscopy and transgastrostomy gastroscopy to dilate a completely obstructed distal esophageal stricture in a child following fundoplication.

    PubMed

    Isaiah, J H; Jones, A B; Lalor, E; Evans, M; Dhunno, I; Huynh, H Q

    2005-08-01

    We report a successful dilation of a completely obstructed distal esophageal stricture in a 4-year-old boy with combined immune deficiency syndrome, at 2 and half years after fundoplication and gastrostomy tube insertion. Barium studies and esophagoscopy had revealed complete obstruction of the lower esophagus. Transgastrostomy gastroscopy demonstrated a pinhole lumen through the fundoplication wrap; a guide wire was passed into the esophagus; and the stricture was dilated with Savary dilators. We presumed that the stricture was secondary to chronic esophagitis. The stricture was identified and successfully dilated using a novel technique of concurrent esophagoscopy and transgastrostomy gastroscopy.

  2. Research on Evaluation and Control of Karst Water Resources in a Certain Tunnel of Dalian Subway

    NASA Astrophysics Data System (ADS)

    Wang, Guang Qiang

    2018-05-01

    Taking a certain tunnel in Dalian Metro as the research object, to evaluate the situation of karst development through geophysical prospecting and drilling data in study area. Karst water resources can be evaluated by quality and quantity in the study area, the correlation of the ion content can be analyzed according to the analysis results of chemical composition of groundwater and the maximum water inflow in karst water section tunnel can be calculated by using the Oshima Yoshi formula. Put forward measures and methods of groundwater control and tube well dewatering based on these evaluation, it has certain guiding significance for tunnel construction in karst area.

  3. A Third Arm for the Surgeon

    NASA Technical Reports Server (NTRS)

    1994-01-01

    In laparoscopic surgery, tiny incisions are made in the patient's body and a laparoscope (an optical tube with a camera at the end) is inserted. The camera's image is projected onto two video screens, whose views guide the surgeon through the procedure. AESOP, a medical robot developed by Computer Motion, Inc. with NASA assistance, eliminates the need for a human assistant to operate the camera. The surgeon uses a foot pedal control to move the device, allowing him to use both hands during the surgery. Miscommunication is avoided; AESOP's movement is smooth and steady, and the memory vision is invaluable. Operations can be completed more quickly, and the patient spends less time under anesthesia. AESOP has been approved by the FDA.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitledge, T.E.; Malloy, S.C.; Patton, C.J.

    This manual was assembled for use as a guide for analyzing the nutrient content of seawater samples collected in the marine coastal zone of the Northeast United States and the Bering Sea. Some modifications (changes in dilution or sample pump tube sizes) may be necessary to achieve optimum measurements in very pronounced oligotrophic, eutrophic or brackish areas. Information is presented under the following section headings: theory and mechanics of automated analysis; continuous flow system description; operation of autoanalyzer system; cookbook of current nutrient methods; automated analyzer and data analysis software; computer interfacing and hardware modifications; and trouble shooting. The threemore » appendixes are entitled: references and additional reading; manifold components and chemicals; and software listings. (JGB)« less

  5. Twin-Screw Extruder Development for the ITER Pellet Injection System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meitner, Steven J; Baylor, Larry R; Combs, Stephen Kirk

    The ITER pellet injection system is comprised of devices to form and accelerate pellets, and will be connected to inner wall guide tubes for fueling, and outer wall guide tubes for ELM pacing. An extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with a gas gun into the plasma. The ITER pellet injection system is required to provide a plasma fueling rate of 120 Pa-m3/s (900 mbar-L/s) and durations of up to 3000 s. The fueling pellets will be injected at a rate up to 10 Hz and pelletsmore » used to trigger ELMs will be injected at higher rates up to 20 Hz. A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. A one-fifth ITER scale prototype has been built and has demonstrated the production of a continuous solid deuterium extrusion. The 27 mm diameter, intermeshed, counter-rotating extruder screws are rotated at a rate up to ≈5 rpm. Deuterium gas is pre-cooled and liquefied and solidified in separate extruder barrels. The precooler consists of a deuterium gas filled copper coil suspended in a separate stainless steel vessel containing liquid nitrogen. The liquefier is comprised of a copper barrel connected to a Cryomech AL330 cryocooler, which has a machined helical groove surrounded by a copper jacket, through which the pre-cooled deuterium condenses. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at ≈15 K) before it is forced through the extruder die. The die forms the extrusion to a 3 mm x 4 mm rectangular cross section. Design improvements have been made to improve the pre-cooler and liquefier heat exchangers, to limit the loss of extrusion through gaps in the screws. This paper will describe the design improvements for the next iteration of the extruder prototype.« less

  6. Phytosulfokine peptide signaling controls pollen tube growth and funicular pollen tube guidance in Arabidopsis thaliana.

    PubMed

    Stührwohldt, Nils; Dahlke, Renate I; Kutschmar, Anke; Peng, Xiongbo; Sun, Meng-Xiang; Sauter, Margret

    2015-04-01

    Phytosulfokine (PSK) is a peptide growth factor that requires tyrosine sulfation carried out by tyrosylprotein sulfotransferase (TPST) for its activity. PSK is processed from precursor proteins encoded by five genes in Arabidopsis thaliana and perceived by receptor kinases encoded by two genes in Arabidopsis. pskr1-3 pskr2-1 and tpst-1 knockout mutants displayed reduced seed production, indicative of a requirement for PSK peptide signaling in sexual plant reproduction. Expression analysis revealed PSK precursor and PSK receptor gene activity in reproductive organs with strong expression of PSK2 in pollen. In support of a role for PSK signaling in pollen, in vitro pollen tube (PT) growth was enhanced by exogenously added PSK while PTs of pskr1-3 pskr2-1 and of tpst-1 were shorter. In planta, growth of wild-type pollen in pskr1-3 pskr2-1 and tpst-1 flowers appeared slower than growth in wild-type flowers. But PTs did eventually reach the base of the style, suggesting that PT elongation rate may not be responsible for the reduced fertility. Detailed analysis of anthers, style and ovules did not reveal obvious developmental defects. By contrast, a high percentage of unfertilized ovules in pskr1-3 pskr2-1 and in tpst-1 siliques displayed loss of funicular PT guidance, suggesting that PSK signaling is required to guide the PT from the transmitting tract to the embryo sac. Cross-pollination experiments with wild-type, pskr1-3 pskr2-1 and tpst-1 male and female parents revealed that both the PT and the female sporophytic tissue and/or female gametophyte contribute to successful PT guidance via PSK signaling and to fertilization success. © 2014 Scandinavian Plant Physiology Society.

  7. Alterations in rotation thromboelastometry (ROTEM®) parameters: point-of-care testing vs analysis after pneumatic tube system transport.

    PubMed

    Martin, J; Schuster, T; Moessmer, G; Kochs, E F; Wagner, K J

    2012-10-01

    Thromboelastometry as point-of-care (POC) testing enables the analysis of the clotting process at the bedside, providing rapid results to guide haemostatic therapy. However, POC testing utilizes medical staff who are managing critically ill patients, as non-laboratory personnel may not be sufficiently trained to run the devices. To resolve these problems, thromboelastometry can be performed in the central laboratory and rapid transport of samples can be accomplished via a pneumatic tube system (PTS). This study compares thromboelastometry parameters of blood samples analysed immediately with those analysed after PTS transport. In patients with normal haemostasis, two arterial blood samples were collected from each patient (n=92) in citrated plastic tubes to investigate the assays INTEM (n=35), EXTEM (n=27), and FIBTEM (n=30). One blood sample was analysed immediately, the other sample after PTS transport. Thromboelastometry was performed using a single ROTEM(®) device. The mean clot firmness values were significantly lower for PTS samples in both the INTEM (-0.7 mm cf. -1.1 mm) and EXTEM (-1.4 cf. -1.7 mm) assays. INTEM coagulation time (CT) was significantly lower in PTS samples with a mean difference of -13 s. EXTEM CT was significantly higher in PTS samples with a mean difference of +3.9 s. Thromboelastometry parameters of blood samples analysed after PTS transport are significantly altered compared with those analysed immediately. However, in patients with normal haemostasis, the alterations were small and without clinical consequence, implying that analysis after PTS transport is an acceptable alternative to prompt analysis at the bedside. Further studies should focus on patients with impaired haemostasis.

  8. Does Preoperative Platelet Function Predict Bleeding in Patients Undergoing Off Pump Coronary Artery Bypass Surgery?

    PubMed

    Berger, Peter B; Kirchner, H Lester; Wagner, Eric S; Ismail-Sayed, Ibrahim; Yahya, Salma; Benoit, Charles; Blankenship, James C; Carter, Russell; Casale, Alfred S; Green, Sandy M; Scott, Thomas D; Skelding, Kimberly A; Woods, Edward; Henry, Yvette M

    2015-06-01

    We sought to examine the relationship between preoperative platelet function and perioperative bleeding in patients undergoing CABG. There are many ways to measure platelet aggregability. Little is known about their correlations with one another, or with bleeding. We prospectively studied 50 patients undergoing a first isolated off-pump CABG. Thirty-four were exposed to a thienopyridine prior to surgery; 16 were not. Preoperative platelet function was measured by VerifyNow®, TEG®, AggreGuide™, Plateletworks®, vasodilator-stimulated phosphoprotein (VASP) phosphorylation, and light transmission aggregometry. Bleeding was assessed 2 ways: drop from pre- to nadir postoperative hematocrit, and chest tube drainage. Correlation coefficients were calculated using Spearman's rank-order correlation. Mean age was 62 years. Patient characteristics and surgical details were similar between the thienopyridine-exposed and non-exposed patients. The correlation coefficients between the 4 point-of-care platelet function measurements and hematocrit change ranged from -0.2274 to 0.2882. Only Plateletworks® correlated with drop in hematocrit (r = 0.2882, P = 0.0470). The correlation coefficients between each of the 4 point-of-care platelet function tests and the chest tube drainage were also poor, ranging from -0.3073 to 0.2272. Both AggreGuide™ (r = -0.3073, P = 0.0317) and VASP (r = -0.3187, P = 0.0272) were weakly but significantly correlated with chest tube drainage. The correlation among the 4 point-of-care platelet function measurements was poor, with coefficients ranging from -0.2504 to 0.1968. We observed little correlation among 4 platelet function tests, and between those assays and perioperative bleeding defined 2 different ways. Whether any of these assays should be used to guide decision making in individual patients is unclear. © 2015, Wiley Periodicals, Inc.

  9. A User’s Guide to the PLTEMP/ANL Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olson, A. P.; Kalimullah, M.; Feldman, E. E.

    2016-07-25

    PLTEMP/ANL V4.2 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each withmore » its own axial power shape. The temperature solution is effectively 2-dimensional. It begins with a one-dimensional solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available with which to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.« less

  10. Ultrasound-guided microinjection into the mouse forebrain in utero at E9.5.

    PubMed

    Pierfelice, Tarran J; Gaiano, Nicholas

    2010-11-13

    In utero survival surgery in mice permits the molecular manipulation of gene expression during development. However, because the uterine wall is opaque during early embryogenesis, the ability to target specific parts of the embryo for microinjection is greatly limited. Fortunately, high-frequency ultrasound imaging permits the generation of images that can be used in real time to guide a microinjection needle into the embryonic region of interest. Here we describe the use of such imaging to guide the injection of retroviral vectors into the ventricular system of the mouse forebrain at embryonic day (E) 9.5. This method uses a laparotomy to permit access to the uterine horns, and a specially designed plate that permits host embryos to be bathed in saline while they are imaged and injected. Successful surgeries often result in most or all of the injected embryos surviving to any subsequent time point of interest (embryonically or postnatally). The principles described here can be used with slight modifications to perform injections into the amnionic fluid of E8.5 embryos (thereby permitting infection along the anterior posterior extent of the neural tube, which has not yet closed), or into the ventricular system of the brain at E10.5/11.5. Furthermore, at mid-neurogenic ages (~E13.5), ultrasound imaging can be used direct injection into specific brain regions for viral infection or cell transplantation. The use of ultrasound imaging to guide in utero injections in mice is a very powerful technique that permits the molecular and cellular manipulation of mouse embryos in ways that would otherwise be exceptionally difficult if not impossible.

  11. Does Sleeve Shape Make a Difference in Outcomes?

    PubMed

    Alhaj Saleh, Adel; Janik, Michal R; Mustafa, Rami R; Alshehri, Mohammed; Khan, Adil H; Kalantar Motamedi, Seyed Mohammad; Rahim, Shiraz; Patel, Indravadan; Aryaie, Amir; Abbas, Mujjahid; Rogula, Tomasz; Khaitan, Leena

    2018-06-01

    Sleeve gastrectomy (SG) is one of the most common procedures performed for weight loss. Many seek the "perfect sleeve" with the notion that the type of calibrating device affects sleeve shape, and this in turn will affect outcomes and complications. Two major concerns after SG are amount of weight loss and acid reflux. Our aim was to determine if the various calibration methods could impact sleeve shape and thereby allow for better outcomes of weight loss and reflux. A retrospective chart review was performed of 210 patients who underwent SG and had postoperative upper gastrointestinal (UGI) study from 2011 to 2015 in a single center by a single (fellowship-trained) bariatric surgeon. Data regarding demographics, calibrating devices and clinical outcomes at 1 year (weight loss and de novo acid reflux) were collected. UGIs were reviewed by two radiologists blinded to the clinical outcomes. Sleeve shape was classified according to a previously described classification as tubular, dumbbell, upper pouch, or lower pouch. The types of calibrating devices used to guide the sleeve size intraoperatively were endoscopy, large-bore orogastric tube, and fenestrated suction tube. One hundred ninety-nine patients met inclusion criteria (11 had no esophagram). Demographics revealed age 45.76 ± 10.6 years, BMI 47 ± 8.6 kg/m 2 , and 82% female. Calibration devices used were endoscopic guidance (7.6%), large bore orogastric tube (41.4%), and fenestrated suction tube (50.5%). Sleeve shape was reported as 32.6% tubular, 20.6% dumbbell, 39.2% lower pouch, and 7.5% upper pouch (100% interrater reliability). No correlation was seen with type of calibration used. Of patients, 62.0% had > 50% excess weight loss at 1 year. Twenty-three percent of patients remained on PPI at 1 year (of which 43.3% did not have reflux preoperatively). The lower pouch shape showed a trend toward less reflux and more weight loss. This study showed no clear association between uniformity of sleeve shape and the type of calibration device used. The study showed a trend toward decreased reflux and improved weight loss with the lower pouch shape, regardless of calibration device.

  12. Technique of after-loading interstitial implants.

    PubMed

    Syed, A M; Feder, B H

    1977-01-01

    Interstitial implants are either removable or permanent (and occasionally a combination of both). Permanent implants are generally utilized where tumors are not accessible enough to permit easy removal of sources or where accurate source distribution is less critical. They are useful for cancers of the lung, pancreas, prostate, bladder, lymph nodes, etc. Radon and gold-198 have been largely replaced by iodine-125. Our major interests are in the removable after-loading iridium-192 implant techniques. Template (steel guide) and non-template (plastic tube) techniques are utilized. Templates are preferred where the tumor volume can only be approached from one side and where accurate positioning of sources would otherwise be difficult. They are useful for cancers of the cervix, vagina, urethra, and rectum. Non-template (plastic tube) techniques are preferred where the tumor volume can be approached from at least two sides and where templates are either not feasible or not essential for accurate positioning of sources. The single needle non-template approach is useful for cancers of lip, nodes, and breast (plastic button) and for cancers of the oral cavity and oropharynx (gold button). The paired needle non-template approach is useful for cancers of the gum, retromolar trigone, and base of tongue (loop technique) and for cancers of the palate (arch technique). Procedures for each technique are described in detail.

  13. On the performance of a high head Francis turbine at design and off-design conditions

    NASA Astrophysics Data System (ADS)

    Aakti, B.; Amstutz, O.; Casartelli, E.; Romanelli, G.; Mangani, L.

    2015-01-01

    In the present paper, fully 360 degrees transient and steady-state simulations of a Francis turbine were performed at three operating conditions, namely at part load (PL), best efficiency point (BEP), and high load (HL), using different numerical approaches for the pressure-velocity coupling. The simulation domain includes the spiral casing with stay and guide vanes, the runner and the draft tube. The main target of the investigations is the numerical prediction of the overall performance of the high head Francis turbine model as well as local and integral quantities of the complete machine in different operating conditions. All results were compared with experimental data published by the workshop organization. All CFD simulations were performed at model scale with a new in-house, 3D, unstructured, object-oriented finite volume code within the framework of the open source OpenFOAM library. The novel fully coupled pressure-based solver is designed to solve the incompressible RANS- Equations and is capable of handling multiple references of frame (MRF). The obtained results show that the overall performance is well captured by the simulations. Regarding the local flow distributions within the inlet section of the draft-tube, the axial velocity is better estimated than the circumferential component.

  14. Testing of Photomultiplier Tubes in a Magnetic Field

    NASA Astrophysics Data System (ADS)

    Waldron, Zachary; A1 Collaboration

    2016-09-01

    The A1 collaboration at MAMI in Mainz, Germany has designed a neutron detector that can be used in experiments to measure the electric form factor of the neutron. They will measure elastic scattering from the neutron, using the polarized electron beam from MAMI at A1's experimental hall. The detector will be composed of two walls of staggered scintillator bars which will be read out by photomultiplier tubes (PMT), connected to both ends of each scintillator via light guides. The experiment requires a magnetic field with strength of 1 Tesla, 2m away from the first scintillator wall. The resulting fringe field is sufficient to disrupt the PMTs, despite the addition of Mu Metal shielding. The effects of the fringe field on these PMTs was tested to optimize the amplification of the PMTs. A Helmholtz Coil was designed to generate a controlled magnetic field with equivalent strength to the field that the PMTs will encounter. The PMTs were read out using a multi-channel analyzer, were tested at various angles relative to the magnetic field in order to determine the optimal orientation to minimize signal disruption. Tests were also performed to determine: the neutron detector response to cosmic radiation; and the best method for measuring a magnetic field's strength in two dimensions. National Science Foundation Grant No. IIA-1358175.

  15. Tiny bubbles challenge giant turbines: Three Gorges puzzle.

    PubMed

    Li, Shengcai

    2015-10-06

    Since the birth of the first prototype of the modern reaction turbine, cavitation as conjectured by Euler in 1754 always presents as a challenge. Following his theory, the evolution of modern reaction (Francis and Kaplan) turbines has been completed by adding the final piece of the element 'draft-tube' that enables turbines to explore water energy at efficiencies of almost 100%. However, during the last two and a half centuries, with increasing unit capacity and specific speed, the problem of cavitation has been manifested and complicated by the draft-tube surges rather than being solved. Particularly, during the last 20 years, the fierce competition in the international market for extremely large turbines with compact design has encouraged the development of giant Francis turbines of 700-1000 MW. The first group (24 units) of such giant turbines of 700 MW each was installed in the Three Gorges project. Immediately after commission, a strange erosion phenomenon appeared on the guide vane of the machines that has puzzled professionals. From a multi-disciplinary analysis, this Three Gorges puzzle could reflect an unknown type of cavitation inception presumably triggered by turbulence production from the boundary-layer streak transitional process. It thus presents a fresh challenge not only to this old turbine industry, but also to the fundamental sciences.

  16. Microfabricated bragg waveguide

    DOEpatents

    Fleming, James G.; Lin, Shawn-Yu; Hadley, G. Ronald

    2004-10-19

    A microfabricated Bragg waveguide of semiconductor-compatible material having a hollow core and a multilayer dielectric cladding can be fabricated by integrated circuit technologies. The microfabricated Bragg waveguide can comprise a hollow channel waveguide or a hollow fiber. The Bragg fiber can be fabricated by coating a sacrificial mandrel or mold with alternating layers of high- and low-refractive-index dielectric materials and then removing the mandrel or mold to leave a hollow tube with a multilayer dielectric cladding. The Bragg channel waveguide can be fabricated by forming a trench embedded in a substrate and coating the inner wall of the trench with a multilayer dielectric cladding. The thicknesses of the alternating layers can be selected to satisfy the condition for minimum radiation loss of the guided wave.

  17. Magnetic properties of superparamagnetic nanoparticles loaded into silicon nanotubes.

    PubMed

    Granitzer, Petra; Rumpf, Klemens; Gonzalez, Roberto; Coffer, Jeffery; Reissner, Michael

    2014-01-01

    In this work, the magnetic properties of silicon nanotubes (SiNTs) filled with Fe3O4 nanoparticles (NPs) are investigated. SiNTs with different wall thicknesses of 10 and 70 nm and an inner diameter of approximately 50 nm are prepared and filled with superparamagnetic iron oxide nanoparticles of 4 and 10 nm in diameter. The infiltration process of the NPs into the tubes and dependence on the wall-thickness is described. Furthermore, data from magnetization measurements of the nanocomposite systems are analyzed in terms of iron oxide nanoparticle size dependence. Such biocompatible nanocomposites have potential merit in the field of magnetically guided drug delivery vehicles. 61.46.Fg; 62.23.Pq; 75.75.-c; 75.20.-g.

  18. Experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum tube

    NASA Astrophysics Data System (ADS)

    Toufexis, Filippos; Tantawi, Sami G.; Jensen, Aaron; Dolgashev, Valery A.; Haase, Andrew; Fazio, Michael V.; Borchard, Philipp

    2017-06-01

    We report the experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum electronic device, which uses an over-moded spherical sector output cavity. In this device, a pencil electron beam is helically deflected in a transverse deflecting cavity before entering the output cavity. No magnetic field is required to focus or guide the beam. We built and tested a proof-of-principle device with an output frequency of 57.12 GHz. The measured peak power was 52.67 W at the 5th harmonic of the drive frequency. Power at the 4th, 6th, and 7th harmonics was 33.28 dB lower than that at the 5th harmonic.

  19. Experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum tube

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toufexis, Filippos; Tantawi, Sami G.; Jensen, Aaron

    Here, we report the experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum electronic device, which uses an over-moded spherical sector output cavity. In this device, a pencil electron beam is helically deflected in a transverse deflecting cavity before entering the output cavity. No magnetic field is required to focus or guide the beam. We built and tested a proof-of-principle device with an output frequency of 57.12 GHz. The measured peak power was 52.67 W at the 5th harmonic of the drive frequency. Power at the 4th, 6th, and 7th harmonics was 33.28 dB lower than that at themore » 5th harmonic.« less

  20. Experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum tube

    DOE PAGES

    Toufexis, Filippos; Tantawi, Sami G.; Jensen, Aaron; ...

    2017-06-26

    Here, we report the experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum electronic device, which uses an over-moded spherical sector output cavity. In this device, a pencil electron beam is helically deflected in a transverse deflecting cavity before entering the output cavity. No magnetic field is required to focus or guide the beam. We built and tested a proof-of-principle device with an output frequency of 57.12 GHz. The measured peak power was 52.67 W at the 5th harmonic of the drive frequency. Power at the 4th, 6th, and 7th harmonics was 33.28 dB lower than that at themore » 5th harmonic.« less

  1. Laboratory Experiment of Magnetic Reconnection between Merging Flux Tubes with Strong Guide FIeld

    NASA Astrophysics Data System (ADS)

    Inomoto, M.; Kamio, S.; Kuwahata, A.; Ono, Y.

    2013-12-01

    Magnetic reconnection governs variety of energy release events in the universe, such as solar flares, geomagnetic substorms, and sawtooth crash in laboratory nuclear fusion experiments. Differently from the classical steady reconnection models, non-steady behavior of magnetic reconnection is often observed. In solar flares, intermittent enhancement of HXR emission is observed synchronously with multiple ejection of plammoids [1]. In laboratory reconnection experiments, the existence of the guide field, that is perpendicular to the reconnection field, makes significant changes on reconnection process. Generally the guide field will slow down the reconnection rate due to the increased magnetic pressure inside the current sheet. It also brings about asymmetric structure of the separatrices or effective particle acceleration in collisionless conditions. We have conducted laboratory experiments to study the behavior of the guide-field magnetic reconnection using plasma merging technique (push reconnection). Under substantial guide field even larger than the reconnection field, the reconnection generally exhibits non-steady feature which involves intermittent detachment of X-point and reconnection current center[2]. Transient enhancement of reconnection rate is observed simultaneously with the X-point motion[3]. We found two distinct phenomena associated with the guide-field non-steady reconnection. The one is the temporal and localized He II emission from X-point region, suggesting the production of energetic electrons which could excite the He ions in the vicinity of the X-point. The other is the excitation of large-amplitude electromagnetic waves which have similar properties with kinetic Alfven waves, whose amplitude show positive correlation with the enhancement of the reconnection electric field[4]. Electron beam instability caused by the energetic electrons accelerated to more than twice of the electron thermal velocity could be a potential driver of the monochromatic magnetic fluctuations. In conclusion, the laboratory guide field reconnection experiments showed some unique features such as ejection of current sheet, localized enhancement of emission, and excitation of low frequency waves, suggesting intermittent fast reconnection mechanism with significant electron acceleration. [1] N. Nishizuka et al., Astrophysical J. 711, 1062 (2010). [2] Y. Ono et al., Phys. Plasmas 18, 111213 (2011). [3] M. Inomoto et al., Plasma and Fusion Res. 8, 2401112 (2013). [4] M. Inomoto et al., Phys. Plasmas 20, 061209 (2013).

  2. Preliminary investigation of flow dynamics during the start-up of a bulb turbine model

    NASA Astrophysics Data System (ADS)

    Coulaud, M.; Fraser, R.; Lemay, J.; Duquesne, P.; Aeschlimann, V.; Deschênes, C.

    2016-11-01

    Nowadays, the electricity network undergoes more perturbations due to the market demand. Additionally, an increase of the production from alternative resources such as wind or solar also induces important variations on the grid. Hydraulic power plants are used to respond quickly to these variations to stabilize the network. Hydraulic turbines have to face more frequent start-up and stop sequences that might shorten significantly their life time. In this context, an experimental analysis of start-up sequences has been conducted on the bulb turbine model of the BulbT project at the Hydraulic Machines Laboratory (LAMH) of Laval University. Maintaining a constant head, guide vanes are opened from 0 ° to 30 °. Three guide vanes opening speed have been chosen from 5 °/s to 20 °/s. Several repetitions were done for each guide vanes opening speed. During these sequences, synchronous time resolved measurements have been performed. Pressure signals were recorded at the runner inlet and outlet and along the draft tube. Also, 25 pressure measurements and strain measurements were obtained on the runner blades. Time resolved particle image velocimetry were used to evaluate flowrate during start-up for some repetitions. Torque fluctuations at shaft were also monitored. This paper presents the experimental set-up and start-up conditions chosen to simulate a prototype start-up. Transient flowrate methodology is explained and validation measurements are detailed. The preliminary results of global performances and runner pressure measurements are presented.

  3. Development of high-resolution two-dimensional magnetic field measurement system by use of printed-circuit technology

    NASA Astrophysics Data System (ADS)

    Akimitsu, Moe; Qinghong, Cao; Sawada, Asuka; Hatano, Hironori; Tanabe, Hiroshi; Ono, Yasushi; TS-Group Team

    2017-10-01

    We have developed a new-types of high-resolution magnetic probe array for our new magnetic reconnection experiments: TS-3U (ST, FRC: R =0.2m, 2017-) and TS-4U (ST, FRC: R =0.5m, 2018-), using the advanced printed-circuit technology. They are equipped with all three-components of magnetic pick-up coils whose size is 1-5mm x 3mm. Each coil is composed of two-sided coil pattern with line width of 0.05mm. We can install two or three printed arrays in a single glass (ceramic) tube for two or three component measurements. Based on this new probe technique, we started high-resolution and high-accuracy measurement of the current sheet thickness and studied its plasma parameter dependence. We found that the thickness of current sheet increases inversely with the guide toroidal field. It is probably determined by the ion gyroradius in agreement with the particle simulation by Horiuchi etc. While the reconnection speed is steady under low guide field condition, it is observed to oscillate in the specific range of guide field, suggesting transition from the quasi-steady reconnection to the intermittent reconnection. Cause and mechanism for intermittent reconnection will be discussed using the current sheet dissipation and dynamic balance between plasma inflow and outflow. This work supported by JSPS KAKENHI Grant Numbers 15H05750, 15K14279 and 17H04863.

  4. An integrated general purpose SiPM based optical module with a high dynamic range

    NASA Astrophysics Data System (ADS)

    Bretz, T.; Engel, R.; Hebbeker, T.; Kemp, J.; Middendorf, L.; Peters, C.; Schumacher, J.; Šmída, R.; Veberič, D.

    2018-06-01

    Silicon photomultipliers (SiPMs) are semiconductor-based light-sensors offering a high gain, a mechanically and optically robust design and high photon detection efficiency. Due to these characteristics, they started to replace conventional photomultiplier tubes in many applications in recent years. This paper presents an optical module based on SiPMs designed for the application in scintillators as well as lab measurements. The module hosts the SiPM bias voltage supply and three pre-amplifiers with different gain levels to exploit the full dynamic range of the SiPMs. Two SiPMs, read-out in parallel, are equipped with light guides to increase the sensitive area. The light guides are optimized for the read-out of wavelength shifting fibers as used in many plastic scintillator detectors. The optical and electrical performance of the module is characterized in detail in laboratory measurements. Prototypes have been installed and tested in a modified version of the Scintillator Surface Detector developed for AugerPrime, the upgrade of the Pierre Auger Observatory. The SiPM module is operated in the Argentinian Pampas and first data proves its usability in such harsh environments.

  5. Aero-thermal investigation of a highly loaded transonic linear turbine guide vane cascade. A test case for inviscid and viscous flow computations

    NASA Astrophysics Data System (ADS)

    Arts, T.; Lambertderouvroit, M.; Rutherford, A. W.

    1990-09-01

    An experimental aerothermal investigation of a highly loaded transonic turbine nozzle guide vane mounted in a linear cascade arrangement is presented. The measurements were performed in a short duration isentropic light piston compression tube facility, allowing a correct simulation of Mach and Reynolds numbers as well as of the gas to wall temperature ratio compared to the values currently observed in modern aeroengines. The experimental program consisted of the following: (1) flow periodicity checks by means of wall static pressure measurements and Schlieren flow visualizations; (2) blade velocity distribution measurements by means of static pressure tappings; (3) blade convective heat transfer measurements by means of static pressure tappings; (4) blade convective heat transfer measurements by means of platinium thin films; (5) downstream loss coefficient and exit flow angle determinations by using a new fast traversing mechanism; and (6) free stream turbulence intensity and spectrum measurements. These different measurements were performed for several combinations of the free stream flow parameters looking at the relative effects on the aerodynamic blade performance and blade convective heat transfer of Mach number, Reynolds number, and freestream turbulence intensity.

  6. Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.

    PubMed

    Moilanen, Petro; Zhao, Zuomin; Karppinen, Pasi; Karppinen, Timo; Kilappa, Vantte; Pirhonen, Jalmari; Myllylä, Risto; Haeggström, Edward; Timonen, Jussi

    2014-03-01

    Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the same side of the coated phantom with a heterodyne interferometer. The FFGW was detected at 30-kHz frequency. Fitting the FFGW phase velocity by the FLC(1,1) tube mode provided an accurate (9.5 ± 4.0%) wall thickness estimate. Ultrasonic in vivo characterization of cortical bone thickness may thus become possible. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. Iterative reconstruction for x-ray computed tomography using prior-image induced nonlocal regularization.

    PubMed

    Zhang, Hua; Huang, Jing; Ma, Jianhua; Bian, Zhaoying; Feng, Qianjin; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2014-09-01

    Repeated X-ray computed tomography (CT) scans are often required in several specific applications such as perfusion imaging, image-guided biopsy needle, image-guided intervention, and radiotherapy with noticeable benefits. However, the associated cumulative radiation dose significantly increases as comparison with that used in the conventional CT scan, which has raised major concerns in patients. In this study, to realize radiation dose reduction by reducing the X-ray tube current and exposure time (mAs) in repeated CT scans, we propose a prior-image induced nonlocal (PINL) regularization for statistical iterative reconstruction via the penalized weighted least-squares (PWLS) criteria, which we refer to as "PWLS-PINL". Specifically, the PINL regularization utilizes the redundant information in the prior image and the weighted least-squares term considers a data-dependent variance estimation, aiming to improve current low-dose image quality. Subsequently, a modified iterative successive overrelaxation algorithm is adopted to optimize the associative objective function. Experimental results on both phantom and patient data show that the present PWLS-PINL method can achieve promising gains over the other existing methods in terms of the noise reduction, low-contrast object detection, and edge detail preservation.

  8. Iterative Reconstruction for X-Ray Computed Tomography using Prior-Image Induced Nonlocal Regularization

    PubMed Central

    Ma, Jianhua; Bian, Zhaoying; Feng, Qianjin; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2014-01-01

    Repeated x-ray computed tomography (CT) scans are often required in several specific applications such as perfusion imaging, image-guided biopsy needle, image-guided intervention, and radiotherapy with noticeable benefits. However, the associated cumulative radiation dose significantly increases as comparison with that used in the conventional CT scan, which has raised major concerns in patients. In this study, to realize radiation dose reduction by reducing the x-ray tube current and exposure time (mAs) in repeated CT scans, we propose a prior-image induced nonlocal (PINL) regularization for statistical iterative reconstruction via the penalized weighted least-squares (PWLS) criteria, which we refer to as “PWLS-PINL”. Specifically, the PINL regularization utilizes the redundant information in the prior image and the weighted least-squares term considers a data-dependent variance estimation, aiming to improve current low-dose image quality. Subsequently, a modified iterative successive over-relaxation algorithm is adopted to optimize the associative objective function. Experimental results on both phantom and patient data show that the present PWLS-PINL method can achieve promising gains over the other existing methods in terms of the noise reduction, low-contrast object detection and edge detail preservation. PMID:24235272

  9. Bioconjugation of recombinant tissue plasminogen activator to magnetic nanocarriers for targeted thrombolysis

    PubMed Central

    Yang, Hung-Wei; Hua, Mu-Yi; Lin, Kun-Ju; Wey, Shiaw-Pyng; Tsai, Rung-Ywan; Wu, Siao-Yun; Lu, Yi-Ching; Liu, Hao-Li; Wu, Tony; Ma, Yunn-Hwa

    2012-01-01

    Low-toxicity magnetic nanocarriers (MNCs) composed of a shell of poly [aniline-co-N-(1-one-butyric acid) aniline] over a Fe3O4 magnetic nanoparticle core were developed to carry recombinant tissue plasminogen activator (rtPA) in MNC-rtPA for targeted thrombolysis. With an average diameter of 14.8 nm, the MNCs exerted superparamagnetic properties. Up to 276 μg of active rtPA was immobilized per mg of MNCs, and the stability of the immobilized rtPA was greatly improved during storage at 4°C and 25°C. In vitro thrombolysis testing with a tubing system demonstrated that magnet-guided MNC-rtPA showed significantly improved thrombolysis compared with free rtPA and reduced the clot lysis time from 39.2 ± 3.2 minutes to 10.8 ± 4.2 minutes. In addition, magnet-guided MNC-rtPA at 20% of the regular rtPA dose restored blood flow within 15–25 minutes of treatment in a rat embolism model without triggering hematological toxicity. In conclusion, this improved system is based on magnetic targeting accelerated thrombolysis and is potentially amenable to therapeutic applications in thromboembolic diseases. PMID:23055728

  10. Development of a fluorimeter using laser-induced single-shot fluorescence lifetime spectroscopy

    NASA Astrophysics Data System (ADS)

    Eisum, Niels H.; Lynggaard-Jensen, Anders

    1990-08-01

    The developed laboratory prototype fluorimeter is the first step to a new in-situ instrument, and is based on a pulsed nitrogen laser (pumping a color dye laser and the laserbeam passing through a frequency doubler) with a pulse width less than 1 nsec. With such a short excitation pulse it is possible to measure the exponential decay of the fluorescence from the aromatic compounds and thus determine the fluorescence lifetime-curves, which are typically in the region of 5-40 nsec. The emitted fluorescence is collected simultaneously in 35 channels in the wavelength region 250-600 nm. If the fluorescence falls within the transmission areas of the interference filters in each channel the light will be collected by a plastic light guide (doped PMMA) in the actual channel and transmitted to the channels photo multiplier tube (PMT). (The use of the plastic light guide improves the sensitivity). The signal from the PMT is passed on to a 200 MHz 8-bit flash AID-converter connected to a local memory. From this local memory the digital lifetime curves from each channel are transmitted to a computer for presentation of the 3-dimensional spectrum. This spectrum has been obtained with a single laser shot.

  11. [Predictive factors of complications during CT-guided transthoracic biopsy].

    PubMed

    Fontaine-Delaruelle, C; Souquet, P-J; Gamondes, D; Pradat, E; de Leusse, A; Ferretti, G R; Couraud, S

    2017-04-01

    CT-guided transthoracic core-needle biopsy (TTNB) is frequently used for the diagnosis of lung nodules. The aim of this study is to describe TTNBs' complications and to investigate predictive factors of complications. All consecutive TTNBs performed in three centers between 2006 and 2012 were included. Binary logistic regression was used for multivariate analysis. Overall, 970 TTNBs were performed in 929 patients. The complication rate was 34% (life-threatening complication in 6%). The most frequent complications were pneumothorax (29% included 4% which required chest-tube) and hemoptysis (5%). The mortality rate was 0.1% (n=1). In multivariate analysis, predictive factor for a complication was small target size (AOR=0.984; 95% CI [0.976-0.992]; P<0.001). This predictive factor was also found for occurrence of life-threatening complication (AOR=0.982; [0.965-0.999]; P=0.037), of pneumothorax (AOR=0.987; [0.978-0.995]; P=0.002) and of hemoptysis (AOR=0.973; [0.951-0.997]; P=0.024). One complication occurred in one-third of TTNBs. The proportion of life-threatening complication was 6%. A small lesion size was predictive of complication occurrence. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. Small bore ceramic laser tube inspection light table

    DOEpatents

    Updike, Earl O.

    1990-01-01

    Apparatus for inspecting small bore ceramic laser tubes, which includes a support base with one or more support rollers. A fluorescent light tube is inserted within the laser tube and the laser tube is supported by the support rollers so that a gap is maintained between the laser tube and the fluorescent tube to enable rotation of the laser tube. In operation, the ceramic tube is illuminated from the inside by the fluorescent tube to facilitate visual inspection. Centering the tube around the axial light of the fluorescent tube provides information about straightness and wall thickness of the laser tube itself.

  13. [Ventilator bundle guided by context of JCI settings can effectively reduce the morbidity of ventilator-associated pneumonia].

    PubMed

    Zhao, Lili; Liu, Lili; Chen, Jing; Yang, Caili; Nie, Jianjian; Zhang, Minwei

    2017-07-01

    To observe the impact of improving the compliance of ventilator bundle on morbidity of ventilator-associated pneumonia (VAP) in intensive care unit (ICU) patients undergoing mechanical ventilation (MV) guided by context of Joint Commission International (JCI) settings, and to study the oral care efficacy of suction tube sponge brush. A prospective study was conducted. The patients who needed MV admitted to Department of Critical Care Medicine of the First Affiliated Hospital of Xiamen University from January 2013 to December 2016 were enrolled. In the context of JCI settings, necessary measurements were taken to enhance the compliance of ventilator bundle each year. In 2013, the preventive measures were set up and the education was strengthened. In 2014, the compliance of hand hygiene and bedside elevation was strengthened. In 2015, a control study was conducted to evaluate the effect between the traditional cotton dipped in chlorhexidine and the suction tube sponge brush rinsed with chlorhexidine on oral health impact parameters. The suction tube sponge brush rinsed with chlorhexidine oral care was introduced to improve compliance. In 2016, electronic bundle checklist for daily self-audits was conducted. The annually morbidity of VAP through the software of hospital and ICU was collected and calculated. The annual incidence of VAP was indicated by the VAP cases per 1 000 MV days. Based on the VAP incidence rate in 2013 as 1, the VAP incidence-rate ratio (IRR) of each year was calculated. During the study period, a total of 2 733 patients admitted to the ICU, including 1 403 patients undergoing MV. Ninety-four of the 1 403 patients with community-acquired pneumonia (CAP), aspiration pneumonia, back elevation ban, incomplete information, and withdrew from the study were excluded. 1 399 patients undergoing MV were enrolled in the final analysis, with total MV days of 11 012 days, and 94 patients occurred VAP. The annual incidence of VAP was progressively declined from 2013 to 2016, and the VAP cases per 1 000 MV days were 17.0, 10.0, 5.9, 3.5 cases, respectively. Based on the VAP incidence rate in 2013, the IRR of VAP from 2014 to 2016 was also progressively declined, which was 0.59 [95% confidence interval (95%CI) = 0.35-0.98], 0.35 (95%CI = 0.18-0.64), and 0.21 (95%CI = 0.09-0.41), with statistical significance (all P < 0.05). In 2013, ICU patients had the lowest rates of bedside elevation and hand hygiene compliance, which were 28.57% and 54.29%, respectively. Compared with 2013, by the implementation of two quality control circle (QCC) projects for bedside elevation and hand hygiene, the rates of bedside elevation and hand hygiene compliance were improved significantly in 2014, which were 82.35%, 91.18%, respectively (both P < 0.05). In 2015, the compliance of chlorhexidine oral care which was the worst performed in 2014 had been improved by the method of QCC, and the rate of the compliance was significantly higher than that in 2013 (87.10% vs. 62.86%, P < 0.05). Compared with 2013, bundle compliance was significantly increased in 2016, except for the sterile operation of the suction tube [daily wake and weaning: 95.00% vs. 71.43%, bedside elevation for over 30degree angle: 92.50% vs. 28.57%, hand hygiene: 97.50% vs. 54.29%, chlorhexidine mouth care once per 6-8 hours: 95.00% vs. 62.86%, turned back and posture drainage: 97.50% vs. 80.00%], the differences were statistically significant (all P < 0.05). The incidences of bad breath, dirt residue and plaque were significantly lower in the group of oral care by using suction tube sponge brush with chlorhexidine (30 cases) compared with the group of traditional cotton pad with chlorhexidine (30 cases; bad breath: 10.0% vs. 40.0% %, dirt residue: 16.7% vs. 70.0%, plaque: 3.3% vs. 30.0%, all P < 0.05). There was no significant difference in the incidence of oral ulcers between the oral brush group and the traditional group (10.0% vs. 30.0%, P > 0.05). Ventilator bundle can effectively reduce the morbidity of VAP in the context of JCI settings, and the oral care by using suction tube sponge brush and chlorhexidine can effectively improve oral hygiene.

  14. Quality of Life and Care Needs of Patients With Persistent or Recurrent Ovarian Cancer, Fallopian Tube Cancer, or Peritoneal Cancer

    ClinicalTrials.gov

    2017-05-03

    Anxiety; Fatigue; Nausea and Vomiting; Neurotoxicity Syndrome; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage I Ovarian Cancer; Stage IA Fallopian Tube Cancer; Stage IB Fallopian Tube Cancer; Stage IC Fallopian Tube Cancer; Stage II Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIB Fallopian Tube Cancer; Stage IIC Fallopian Tube Cancer; Stage III Ovarian Cancer; Stage III Primary Peritoneal Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIC Fallopian Tube Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer

  15. Radiological Shielding Design for the Neutron High-Resolution Backscattering Spectrometer EMU at the OPAL Reactor

    NASA Astrophysics Data System (ADS)

    Ersez, Tunay; Esposto, Fernando; Souza, Nicolas R. de

    2017-09-01

    The shielding for the neutron high-resolution backscattering spectrometer (EMU) located at the OPAL reactor (ANSTO) was designed using the Monte Carlo code MCNP 5-1.60. The proposed shielding design has produced compact shielding assemblies, such as the neutron pre-monochromator bunker with sliding cylindrical block shields to accommodate a range of neutron take-off angles, and in the experimental area - shielding of neutron focusing guides, choppers, flight tube, backscattering monochromator, and additional shielding elements inside the Scattering Tank. These shielding assemblies meet safety and engineering requirements and cost constraints. The neutron dose rates around the EMU instrument were reduced to < 0.5 µSv/h and the gamma dose rates to a safe working level of ≤ 3 µSv/h.

  16. Leak or Fistula After Sleeve Gastrectomy: Treatment with Pigtail Drain by the Rendezvous Technique.

    PubMed

    Soufron, Jacques

    2015-10-01

    After a sleeve gastrectomy, a leak or fistula is a serious complication. Laparoscopic drainage, drainage under US or CT scan control, or endoscopic insertion of a stent can be used, but a major re-operation is sometimes unavoidable. Endoscopic drainage with a pigtail catheter could give more success and fewer complications, but the insertion of the drain is not always possible nor does it always provide a perfect drainage. If a laparoscopic second look appears necessary, it is possible to insert a pigtail drain laparoscopically, but under endoscopic control, ensuring a correct positioning of the drain both in the peritoneal cavity and in the gastric tube. This simultaneous "rendezvous" technique could combine in this situation the advantages of purely surgical techniques and of purely endoscopic or image-guided techniques.

  17. LDEF materials data analysis: Representative examples

    NASA Technical Reports Server (NTRS)

    Pippin, Gary; Crutcher, Russ

    1993-01-01

    Part of the philosophy which guided the examination of hardware from the Long Duration Exposure Facility (LDEF) was that materials present at multiple locations should have fairly high priority for investigation. Properties of such materials were characterized as a function of exposure conditions to obtain as much data as possible for predicting performance lifetimes. Results from examination of several materials from interior locations of LDEF, selected measurements on silverized teflon blanket specimens, and detailed measurements on the copper grounding strap from tray D11 are summarized. Visual observations of interior locations of LDEF made during deintegration at KSC showed apparent changes in particular specimens. This inspection lead to testing of selected nylon clamps, fiberglass shims, and heat shrink tubing from wire harness clamps, and visually discolored silver coated hex nuts.

  18. Chemotherapy Toxicity On Quality of Life in Older Patients With Stage I, Stage II, Stage III, or Stage IV Ovarian Epithelial, Primary Peritoneal Cavity, or Fallopian Tube Cancer

    ClinicalTrials.gov

    2017-05-03

    Stage I Ovarian Cancer; Stage IA Fallopian Tube Cancer; Stage IB Fallopian Tube Cancer; Stage IC Fallopian Tube Cancer; Stage II Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIB Fallopian Tube Cancer; Stage IIC Fallopian Tube Cancer; Stage III Ovarian Cancer; Stage III Primary Peritoneal Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIC Fallopian Tube Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer

  19. Ceramic heat exchanger

    DOEpatents

    LaHaye, Paul G.; Rahman, Faress H.; Lebeau, Thomas P. E.; Severin, Barbara K.

    1998-01-01

    A tube containment system. The tube containment system does not significantly reduce heat transfer through the tube wall. The contained tube is internally pressurized, and is formed from a ceramic material having high strength, high thermal conductivity, and good thermal shock resistance. The tube containment system includes at least one ceramic fiber braid material disposed about the internally pressurized tube. The material is disposed about the tube in a predetermined axial spacing arrangement. The ceramic fiber braid is present in an amount sufficient to contain the tube if the tube becomes fractured. The tube containment system can also include a plurality of ceramic ring-shaped structures, in contact with the outer surface of the tube, and positioned between the tube and the ceramic fiber braid material, and/or at least one transducer positioned within tube for reducing the internal volume and, therefore, the energy of any shrapnel resulting from a tube fracture.

  20. Ceramic heat exchanger

    DOEpatents

    LaHaye, P.G.; Rahman, F.H.; Lebeau, T.P.; Severin, B.K.

    1998-06-16

    A tube containment system is disclosed. The tube containment system does not significantly reduce heat transfer through the tube wall. The contained tube is internally pressurized, and is formed from a ceramic material having high strength, high thermal conductivity, and good thermal shock resistance. The tube containment system includes at least one ceramic fiber braid material disposed about the internally pressurized tube. The material is disposed about the tube in a predetermined axial spacing arrangement. The ceramic fiber braid is present in an amount sufficient to contain the tube if the tube becomes fractured. The tube containment system can also include a plurality of ceramic ring-shaped structures, in contact with the outer surface of the tube, and positioned between the tube and the ceramic fiber braid material, and/or at least one transducer positioned within tube for reducing the internal volume and, therefore, the energy of any shrapnel resulting from a tube fracture. 6 figs.

  1. Advantage of rubber over plastic endotracheal tubes for rapid extubation in a laser fire.

    PubMed

    Sosis, M B; Braverman, B

    1996-04-01

    The occurrence of airway fires during laser airway surgery necessitates the use of special techniques to improve patient safety. For example, it is recommended that the endotracheal tube cuff be inflated with saline. However, in the event of an endotracheal tube fire, the tube must be quickly removed. This study was designed to determine the time necessary for red rubber (RR) or polyvinylchloride (PVC) endotracheal tubes to be removed from a model airway after inflating the cuffs with saline. A model larynx and trachea was suspended vertically. It was intubated with either 7.0 RR or PVC endotracheal tubes. Six milliliters of saline was used to inflate the endotracheal tube cuffs. After inflation, a clamp was used to occlude the pilot tube on the RR endotracheal tubes. A 4-lb weight was then suspended from the endotracheal tube. The time to spontaneous extubation of the model trachea after unclamping the pilot tubes on 12 RR endotracheal tubes was determined. For the PVC endotracheal tubes, the times to spontaneous extubation using the 4-lb weight were determined in 12 endotracheal tubes after cutting the pilot tube and in 12 by maximum aspiration of the saline from the endotracheal tube cuff with a 10-ml syringe. A time of 0.94 +/- 0.10 sec (mean +/- SD) was required for spontaneous extubation of the RR endotracheal tubes after unclamping the pilot tube. For the PVC endotracheal tubes, extubation occurred 3.28 +/- 1.08 and 1.81 +/- 0.60 sec after cutting the pilot tube or deflating the cuff with a syringe, respectively. The mean times for each of the 3 groups were significantly different (p < 0.05) from each other as determined by the ANOVA. This study shows that if PVC endotracheal tubes are used, deflation of the saline-filled cuff by aspiration with a 10-ml syringe is faster than cutting the pilot tube. Unclamping the pilot tube on the RR endotracheal tubes resulted in the fastest time to endotracheal extubation.

  2. Tube support

    DOEpatents

    Mullinax, Jerry L.

    1988-01-01

    A tube support for supporting horizontal tubes from an inclined vertical support tube passing between the horizontal tubes. A support button is welded to the vertical support tube. Two clamping bars or plates, the lower edges of one bearing on the support button, are removably bolted to the inclined vertical tube. The clamping bars provide upper and lower surface support for the horizontal tubes.

  3. Endothelial Progenitor Cells (EPC) Count by Multicolor Flow Cytometry in Healthy Individuals and Diabetes Mellitus (DM) Patients.

    PubMed

    Falay, Mesude; Aktas, Server

    2016-11-01

    The present study aimed to determine circulating Endothelial Progenitor Cell (EPC) counts by multicolor flow cytometry in healthy individuals and diabetic subjects by means of forming an analysis procedure using a combination of monoclonal antibodies (moAbs), which would correctly detect the circulating EPC count. The circulating EPC count was detected in 40 healthy individuals (20 Female, 20 Male; age range: 26 - 50 years) and 30 Diabetes Mellitus (DM) patients (15 Female, 15 Male; age range: 42 - 55) by multicolor flow cytometry (FCM) in a single-tube panel consisting of 5 CD45/CD31/CD34/CD309/ SYTO® and 16 monoclonal antibodies. Circulating EPC count was 11.33 (7.89 - 15.25) cells/µL in the healthy control group and 4.80 (0.70 - 10.85) cells/µL in the DM group. EPC counts were significantly lower in DM cases that developed coronary artery disease (53.3%) as compared to those that did not (p < 0.001). In the present study, we describe a method that identifies circulating EPC counts by multicolor flow cytometry in a single tube and determines the circulating EPC count in healthy individuals. This is the first study conducted on EPC count in Turkish population. We think that the EPC count found in the present study will be a guide for future studies.

  4. PERKAT RV: first in vivo data of a novel right heart assist device.

    PubMed

    Kretzschmar, Daniel; Lauten, Alexander; Schubert, Harald; Bischoff, Sabine; Schulze, Christian; Ferrari, Markus W

    2018-04-06

    Mechanical right ventricular (RV) support offers a treatment option for critically ill patients with RV failure (RVF). We developed an assist device for rapid percutaneous implantation. The aim of the present study was to investigate the implantation procedure, haemodynamic performance and possible side effects of the novel right ventricular assist device - PERKAT RV - in an animal model. The PERkutane KATheterpumptechnologie RV (PERKAT RV) device consists of a nitinol chamber covered by foil containing inflow valves. An outlet tube is attached to its distal part. The system is designed for 18 Fr percutaneous implantation. The chamber is unfolded in the inferior vena cava while the outlet tube bypasses the right heart with the tip in the pulmonary trunk. An IABP balloon is placed inside. Balloon deflation generates blood flow into the chamber; during inflation, blood is guided into the pulmonary arteries. Acute RVF was induced by venous injection of Sephadex in seven sheep for evaluation of the device. The PERKAT RV was able to improve haemodynamics immediately generating a median increase in cardiac output of 59%. Longer pump support was evaluated in a second study. Four sheep were supported for eight hours without any problems. The percutaneous implantation and explantation of the PERKAT RV device was possible in the designed way. The sheep studies proved beneficial haemodynamic effects in acute RVF. The system offers easy and safe treatment in acute RVF.

  5. Validations of CFD against detailed velocity and pressure measurements in water turbine runner flow

    NASA Astrophysics Data System (ADS)

    Nilsson, H.; Davidson, L.

    2003-03-01

    This work compares CFD results with experimental results of the flow in two different kinds of water turbine runners. The runners studied are the GAMM Francis runner and the Hölleforsen Kaplan runner. The GAMM Francis runner was used as a test case in the 1989 GAMM Workshop on 3D Computation of Incompressible Internal Flows where the geometry and detailed best efficiency measurements were made available. In addition to the best efficiency measurements, four off-design operating condition measurements are used for the comparisons in this work. The Hölleforsen Kaplan runner was used at the 1999 Turbine 99 and 2001 Turbine 99 - II workshops on draft tube flow, where detailed measurements made after the runner were used as inlet boundary conditions for the draft tube computations. The measurements are used here to validate computations of the flow in the runner.The computations are made in a single runner blade passage where the inlet boundary conditions are obtained from an extrapolation of detailed measurements (GAMM) or from separate guide vane computations (Hölleforsen). The steady flow in a rotating co-ordinate system is computed. The effects of turbulence are modelled by a low-Reynolds number k- turbulence model, which removes some of the assumptions of the commonly used wall function approach and brings the computations one step further.

  6. COMMIX-PPC: A three-dimensional transient multicomponent computer program for analyzing performance of power plant condensers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chien, T.H.; Domanus, H.M.; Sha, W.T.

    1993-02-01

    The COMMIX-PPC computer pregrain is an extended and improved version of earlier COMMIX codes and is specifically designed for evaluating the thermal performance of power plant condensers. The COMMIX codes are general-purpose computer programs for the analysis of fluid flow and heat transfer in complex Industrial systems. In COMMIX-PPC, two major features have been added to previously published COMMIX codes. One feature is the incorporation of one-dimensional equations of conservation of mass, momentum, and energy on the tube stile and the proper accounting for the thermal interaction between shell and tube side through the porous-medium approach. The other added featuremore » is the extension of the three-dimensional conservation equations for shell-side flow to treat the flow of a multicomponent medium. COMMIX-PPC is designed to perform steady-state and transient. Three-dimensional analysis of fluid flow with heat transfer tn a power plant condenser. However, the code is designed in a generalized fashion so that, with some modification, it can be used to analyze processes in any heat exchanger or other single-phase engineering applications. Volume I (Equations and Numerics) of this report describes in detail the basic equations, formulation, solution procedures, and models for a phenomena. Volume II (User's Guide and Manual) contains the input instruction, flow charts, sample problems, and descriptions of available options and boundary conditions.« less

  7. Thermohydraulic behavior of the liquid metal target of a spallation neutron source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeda, Y.

    1996-06-01

    The author presents work done on three main problems. (1) Natural circulation in double coaxial cylindircal container: The thermohydraulic behaviour of the liquid metal target of the spallation neutron source at PSI has been investigated. The configuration is a natural-circulation loop in a concentric double-tube-type container. The results show that the natural-circulation loop concept is valid for the design phase of the target construction, and the current specified design criteria will be fulfilled with the proposed parameter values. (2) Flow around the window: Water experiments were performed for geometry optimisation of the window shape of the SINQ container for avoidingmore » generating recirculation zones at peripheral area and the optimal cooling of the central part of the beam entrance window. Flow visualisation technique was mainly used for various window shapes, gap distance between the window and the guide tube edge. (3) Flow in window cooling channels: Flows in narrow gaps of cooling channels of two different types of windows were studied by flow visualisation techniques. One type is a slightly curved round cooling channel and the other is hemispherical shape, both of which have only 2 mm gap distance and the water inlet is located on one side and flows out from the opposite side. In both cases, the central part of the flow area has lower velocity than peripheral area.« less

  8. Verifying placement of small-bore feeding tubes: electromagnetic device images versus abdominal radiographs.

    PubMed

    Bryant, Vera; Phang, Jean; Abrams, Kevin

    2015-11-01

    Clinicians are unsure if radiography is needed to confirm correct positioning of feeding tubes inserted with assistance from an electromagnetic system. To compare radiographic reports of feeding tube placement with images generated by an electromagnetic feeding tube placement device. The medical records of 200 consecutive patients who had feeding tubes inserted with assistance from an electromagnetic feeding tube placement device were reviewed retrospectively. Radiographic reports of tube site were compared with images generated by the device. Radiographic evidence of tube sites was available in 188 cases: 184 tubes were located in portions of the gastrointestinal tract. Ninety of the 188 tubes were situated in the optimal site (distal duodenum or jejunum) radiographically. Images generated by the electromagnetic device were available in 176 cases; of these, 52 tubes appeared to end in the expected left lower quadrant. Tubes shown on radiographs to be in other sites also occasionally appeared to end in the left lower quadrant. Nurses using the device did not recognize 4 of the 188 tubes (2.1%) that were inadvertently placed in the lung. No consistent pattern of quadrant distribution was found for tubes positioned in the stomach or proximal duodenum. Images generated by the electromagnetic tube placement device provided inconsistent results regarding tube location. A small percentage of seriously malpositioned tubes were not detected by using the electromagnetic device. These findings do not support eliminating radiographs to confirm correct tube placement following use of an electromagnetic tube placement device. ©2015 American Association of Critical-Care Nurses.

  9. Wellbore manufacturing processes for in situ heat treatment processes

    DOEpatents

    Davidson, Ian Alexander; Geddes, Cameron James; Rudolf, Randall Lynn; Selby, Bruce Allen; MacDonald, Duncan Charles

    2012-12-11

    A method includes making coiled tubing at a coiled tubing manufacturing unit coupled to a coiled tubing transportation system. One or more coiled tubing reels are transported from the coiled tubing manufacturing unit to one or more moveable well drilling systems using the coiled tubing transportation system. The coiled tubing transportation system runs from the tubing manufacturing unit to one or more movable well drilling systems, and then back to the coiled tubing manufacturing unit.

  10. TUBE TESTER

    DOEpatents

    Gittings, H.T. Jr.; Kalbach, J.F.

    1958-01-14

    This patent relates to tube testing, and in particular describes a tube tester for automatic testing of a number of vacuum tubes while in service and as frequently as may be desired. In it broadest aspects the tube tester compares a particular tube with a standard tube tarough a difference amplifier. An unbalanced condition in the circuit of the latter produced by excessive deviation of the tube in its characteristics from standard actuates a switch mechanism stopping the testing cycle and indicating the defective tube.

  11. Protective tubes for sodium heated water tubes

    DOEpatents

    Essebaggers, Jan

    1979-01-01

    A heat exchanger in which water tubes are heated by liquid sodium which minimizes the results of accidental contact between the water and the sodium caused by failure of one or more of the water tubes. A cylindrical protective tube envelopes each water tube and the sodium flows axially in the annular spaces between the protective tubes and the water tubes.

  12. Learning from YouTube [Video Book

    ERIC Educational Resources Information Center

    Juhasz, Alexandra

    2011-01-01

    YouTube is a mess. YouTube is for amateurs. YouTube dissolves the real. YouTube is host to inconceivable combos. YouTube is best for corporate-made community. YouTube is badly baked. These are a few of the things Media Studies professor Alexandra Juhasz (and her class) learned about YouTube when she set out to investigate what actually happens…

  13. Geology of selected lava tubes in the Bend Area, Oregon

    NASA Technical Reports Server (NTRS)

    Greely, R.

    1971-01-01

    Longitudinal profiles representing 5872.5 m of mapped lava tubes and a photogeologic map relating lava tubes to surface geology, regional structure and topography are presented. Three sets of lava tubes were examined: (1) Arnold Lava Tube System (7km long) composed of collapsed and uncollapsed tube segments and lava ponds, (2) Horse Lava Tube System (11 km long) composed of parallel and anastomosing lava tube segments, and (3) miscellaneous lava tubes. Results of this study tend to confirm the layered lava hypothesis of Ollier and Brown (1965) for lava tube formation; however, there are probably several modes of formation for lava tubes in general. Arnold System is a single series of tubes apparently formed in a single basalt flow on a relatively steep gradient. The advancing flow in which the tubes formed was apparently temporarily halted, resulting in the formation of lava ponds which were inflated and later drained by the lava tube system. Horse System probably formed in multiple, interconnected flows. Pre-flow gradient appears to have been less than for Arnold System, and resulted in meandrous, multiple tube networks.

  14. The structure of untwisted magnetic flux tubes. [solar magnetic field distribution

    NASA Technical Reports Server (NTRS)

    Browning, P. K.; Priest, E. R.

    1982-01-01

    While most previous investigations have concentrated on slender flux tubes, the present study of the equilibrium structure of an axisymmetric magnetic flux tube, confined by an external pressure that varies along the length of the tube, explores the properties of thick tubes in order to establish the degree to which slender tube theory is valid. It is found that slender flux tube results may in some cases give no indication of thick tube behavior in a nonuniform atmosphere. Depending on boundary conditions applied at the ends of the tube, it may expand or contract upon entering a region of increasing pressure. Rather than expanding indefinitely, the tube surface may form a cusped shape when a point of external pressure on the tube surface falls to equality with the internal pressure. Numerical solutions for an initially uniform tube give smaller expansions than would be expected from slender tube theory.

  15. Eddy current signal comparison for tube identification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, S. W., E-mail: Bill.Glass@areva.com, E-mail: Ratko.Vojvodic@areva.com; Vojvodic, R., E-mail: Bill.Glass@areva.com, E-mail: Ratko.Vojvodic@areva.com

    2015-03-31

    Inspection of nuclear power plant steam generator tubes is required to justify continued safe plant operation. The steam generators consist of thousands of tubes with nominal diameters of 15 to 22mm, approximately 1mm wall thickness, and 20 to 30m in length. The tubes are inspected by passing an eddy current probe through the tubes from tube end to tube end. It is critical to know exactly which tube identification (row and column) is associated with each tube's data. This is controlled by a precision manipulator that provides the tube ID to the eddy current system. Historically there have been somemore » instances where the manipulator incorrectly reported the tube ID. This can have serious consequences including lack of inspection of a tube, or if a pluggable indication is detected, the tube is likely to be mis-plugged thereby risking a primary to secondary leak.« less

  16. Carboplatin and Paclitaxel or Oxaliplatin and Capecitabine With or Without Bevacizumab as First-Line Therapy in Treating Patients With Newly Diagnosed Stage II-IV or Recurrent Stage I Epithelial Ovarian or Fallopian Tube Cancer

    ClinicalTrials.gov

    2017-08-21

    Borderline Ovarian Mucinous Tumor; Ovarian Mucinous Cystadenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Stage IA Fallopian Tube Cancer; Stage IA Ovarian Cancer; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Cancer; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer

  17. Standardizing adult tracheostomy tube styles: what is the clinical and cost-effective impact?

    PubMed

    Crimlisk, Janet T; O'Donnell, Charles; Grillone, Gregory A

    2006-01-01

    Tracheostomy tubes are made of a variety of materials, components, and styles. In a recent merger of our hospitals, we noted a large assortment of tubes available for clinicians. The different tubes resulted in complaints from staff, which included confusion, delays in obtaining preferred tubes, and inconsistent shelf stock. A multidisciplinary task force was formed to recommend standardizing the styles of tracheostomy tubes. A comparison of tracheotomy procedures, tracheostomy tube usage, and tube costs were done 6 months before and 6 months after the standardization. The number of tube styles decreased from 9 to 4; specialty extra-long tubes decreased from 3 to 2. There were no cost savings in standardizing the tracheostomy tubes.

  18. Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Surry, K. J. M.; Mills, G. R.; Bevan, K.

    2007-11-15

    Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM andmore » US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLE{sub z} of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FRE{sub z} of 0.76 mm and a TRE{sub z} of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target localization. The system will provide preprocedural x-ray mammography information in the form of SM imaging along with real-time US imaging for needle guidance to a target. 3D US imaging will also be available for targeting, guidance, and biopsy verification immediately postbiopsy.« less

  19. 49 CFR 230.61 - Arch tubes, water bar tubes, circulators and thermic siphons.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Arch tubes, water bar tubes, circulators and... MAINTENANCE STANDARDS Boilers and Appurtenances Washing Boilers § 230.61 Arch tubes, water bar tubes... water bar tubes shall thoroughly be cleaned mechanically, washed, and inspected. Circulators and thermic...

  20. FY 2016 Status Report: Documentation of All CIRFT Data including Hydride Reorientation Tests (Draft M2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jy-An John; Wang, Hong; Jiang, Hao

    The first portion of this report provides a detailed description of fiscal year (FY) 2015 test result corrections and analysis updates based on FY 2016 updates to the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) program methodology, which is used to evaluate the vibration integrity of spent nuclear fuel (SNF) under normal conditions of transport (NCT). The CIRFT consists of a U-frame test setup and a real-time curvature measurement method. The three-component U-frame setup of the CIRFT has two rigid arms and linkages connecting to a universal testing machine. The curvature SNF rod bending is obtained through a three-point deflection measurementmore » method. Three linear variable differential transformers (LVDTs) are clamped to the side connecting plates of the U-frame and used to capture deformation of the rod. The second portion of this report provides the latest CIRFT data, including data for the hydride reorientation test. The variations in fatigue life are provided in terms of moment, equivalent stress, curvature, and equivalent strain for the tested SNFs. The equivalent stress plot collapsed the data points from all of the SNF samples into a single zone. A detailed examination revealed that, at the same stress level, fatigue lives display a descending order as follows: H. B. Robinson Nuclear Power Station (HBR), LMK, and mixed uranium-plutonium oxide (MOX). Just looking at the strain, LMK fuel has a slightly longer fatigue life than HBR fuel, but the difference is subtle. The third portion of this report provides finite element analysis (FEA) dynamic deformation simulation of SNF assemblies . In a horizontal layout under NCT, the fuel assembly’s skeleton, which is formed by guide tubes and spacer grids, is the primary load bearing apparatus carrying and transferring vibration loads within an SNF assembly. These vibration loads include interaction forces between the SNF assembly and the canister basket walls. Therefore, the integrity of the guide tubes and spacer grids critically affects the vibration intensity of the fuel assembly during transport and must be considered when developing the multipurpose purpose canister (MPC) design for safe SNF transport.« less

  1. Bender/Coiler for Tubing

    NASA Technical Reports Server (NTRS)

    Stoltzfus, J. M.

    1983-01-01

    Easy-to-use tool makes coils of tubing. Tubing to be bend clamped with stop post. Die positioned snugly against tubing. Operator turns handle to slide die along tubing, pushing tubing into spiral groove on mandrel.

  2. Premixed direct injection nozzle for highly reactive fuels

    DOEpatents

    Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin Paul; York, William David; Uhm, Jong Ho; Zuo, Baifang

    2013-09-24

    A fuel/air mixing tube for use in a fuel/air mixing tube bundle is provided. The fuel/air mixing tube includes an outer tube wall extending axially along a tube axis between an inlet end and an exit end, the outer tube wall having a thickness extending between an inner tube surface having a inner diameter and an outer tube surface having an outer tube diameter. The tube further includes at least one fuel injection hole having a fuel injection hole diameter extending through the outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.

  3. Effects of a Multidisciplinary Approach to Improve Volume of Diagnostic Material in CT-Guided Lung Biopsies.

    PubMed

    Ferguson, Philip E; Sales, Catherine M; Hodges, Dalton C; Sales, Elizabeth W

    2015-01-01

    Recent publications have emphasized the importance of a multidisciplinary strategy for maximum conservation and utilization of lung biopsy material for advanced testing, which may determine therapy. This paper quantifies the effect of a multidisciplinary strategy implemented to optimize and increase tissue volume in CT-guided transthoracic needle core lung biopsies. The strategy was three-pronged: (1) once there was confidence diagnostic tissue had been obtained and if safe for the patient, additional biopsy passes were performed to further increase volume of biopsy material, (2) biopsy material was placed in multiple cassettes for processing, and (3) all tissue ribbons were conserved when cutting blocks in the histology laboratory. This study quantifies the effects of strategies #1 and #2. This retrospective analysis comparing CT-guided lung biopsies from 2007 and 2012 (before and after multidisciplinary approach implementation) was performed at a single institution. Patient medical records were reviewed and main variables analyzed include biopsy sample size, radiologist, number of blocks submitted, diagnosis, and complications. The biopsy sample size measured was considered to be directly proportional to tissue volume in the block. Biopsy sample size increased 2.5 fold with the average total biopsy sample size increasing from 1.0 cm (0.9-1.1 cm) in 2007 to 2.5 cm (2.3-2.8 cm) in 2012 (P<0.0001). The improvement was statistically significant for each individual radiologist. During the same time, the rate of pneumothorax requiring chest tube placement decreased from 15% to 7% (P = 0.065). No other major complications were identified. The proportion of tumor within the biopsy material was similar at 28% (23%-33%) and 35% (30%-40%) for 2007 and 2012, respectively. The number of cases with at least two blocks available for testing increased from 10.7% to 96.4% (P<0.0001). The effect of this multidisciplinary strategy to CT-guided lung biopsies was effective in significantly increasing tissue volume and number of blocks available for advanced diagnostic testing.

  4. Paclitaxel, Polyglutamate Paclitaxel, or Observation in Treating Patients With Stage III or Stage IV Ovarian Epithelial, Peritoneal Cancer, or Fallopian Tube Cancer

    ClinicalTrials.gov

    2017-05-03

    Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Ovarian Brenner Tumor; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma

  5. Pulse tube cooler having 1/4 wavelength resonator tube instead of reservoir

    NASA Technical Reports Server (NTRS)

    Gedeon, David R. (Inventor)

    2008-01-01

    An improved pulse tube cooler having a resonator tube connected in place of a compliance volume or reservoir. The resonator tube has a length substantially equal to an integer multiple of 1/4 wavelength of an acoustic wave in the working gas within the resonator tube at its operating frequency, temperature and pressure. Preferably, the resonator tube is formed integrally with the inertance tube as a single, integral tube with a length approximately 1/2 of that wavelength. Also preferably, the integral tube is spaced outwardly from and coiled around the connection of the regenerator to the pulse tube at a cold region of the cooler and the turns of the coil are thermally bonded together to improve heat conduction through the coil.

  6. Tube-in-tube thermophotovoltaic generator

    DOEpatents

    Ashcroft, John; Campbell, Brian; DePoy, David

    1998-01-01

    A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell.

  7. Eddy-Current Detection of Cracks in Tubes

    NASA Technical Reports Server (NTRS)

    Parent, R.; Kettering, D.

    1987-01-01

    Nondestructive device tests narrow, sharply-bent metal tubes. Eddycurrent probe detects incipient cracks inside small metal tubes. Tube-centering device consisting of pair of opposed bars ensures tube centered on eddy-current coil. Probe moves along length of bent tube to inspect repeatably for cracks. Compatible with tubes of different cross sections, oval, flattened, square, rectangular,or irregular. Adapts for inspecting formed tubes in petrochemical, automotive, nuclear, and medical equipment.

  8. Vaccine Therapy in Treating Patients With Stage IIIC-IV Ovarian Epithelial, Fallopian Tube, or Primary Peritoneal Cavity Cancer Following Surgery and Chemotherapy

    ClinicalTrials.gov

    2017-10-12

    Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Tumor; Fallopian Tube Mucinous Neoplasm; Fallopian Tube Serous Neoplasm; Fallopian Tube Transitional Cell Carcinoma; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Cystadenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma

  9. In-bed tube bank for a fluidized-bed combustor

    DOEpatents

    Hemenway, Jr., Lloyd F.

    1990-01-01

    An in-bed tube bank (10) for a fluidized bed combustor. The tube bank (10) of the present invention comprises one or more fluid communicating boiler tubes (30) which define a plurality of selectively spaced boiler tube sections (32). The tube sections (32) are substantially parallel to one another and aligned in a common plane. The tube bank (10) further comprises support members (34) for joining adjacent tube sections (32), the support members (34) engaging and extending along a selected length of the tube sections (32) and spanning the preselected space therebetween.

  10. Tissue-engineered spiral nerve guidance conduit for peripheral nerve regeneration.

    PubMed

    Chang, Wei; Shah, Munish B; Lee, Paul; Yu, Xiaojun

    2018-06-01

    Recently in peripheral nerve regeneration, preclinical studies have shown that the use of nerve guidance conduits (NGCs) with multiple longitudinally channels and intra-luminal topography enhance the functional outcomes when bridging a nerve gap caused by traumatic injury. These features not only provide guidance cues for regenerating nerve, but also become the essential approaches for developing a novel NGC. In this study, a novel spiral NGC with aligned nanofibers and wrapped with an outer nanofibrous tube was first developed and investigated. Using the common rat sciatic 10-mm nerve defect model, the in vivo study showed that a novel spiral NGC (with and without inner nanofibers) increased the successful rate of nerve regeneration after 6 weeks recovery. Substantial improvements in nerve regeneration were achieved by combining the spiral NGC with inner nanofibers and outer nanofibrous tube, based on the results of walking track analysis, electrophysiology, nerve histological assessment, and gastrocnemius muscle measurement. This demonstrated that the novel spiral NGC with inner aligned nanofibers and wrapped with an outer nanofibrous tube provided a better environment for peripheral nerve regeneration than standard tubular NGCs. Results from this study will benefit for future NGC design to optimize tissue-engineering strategies for peripheral nerve regeneration. We developed a novel spiral nerve guidance conduit (NGC) with coated aligned nanofibers. The spiral structure increases surface area by 4.5 fold relative to a tubular NGC. Furthermore, the aligned nanofibers was coated on the spiral walls, providing cues for guiding neurite extension. Finally, the outside of spiral NGC was wrapped with randomly nanofibers to enhance mechanical strength that can stabilize the spiral NGC. Our nerve histological data have shown that the spiral NGC had 50% more myelinated axons than a tubular structure for nerve regeneration across a 10 mm gap in a rat sciatic nerve. Results from this study can help further optimize tissue engineering strategies for peripheral nerve repair. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Accuracy of endoscopic intraoperative assessment of urologic stone size.

    PubMed

    Patel, Nishant; Chew, Ben; Knudsen, Bodo; Lipkin, Michael; Wenzler, David; Sur, Roger L

    2014-05-01

    Endoscopic treatment of renal calculi relies on surgeon assessment of residual stone fragment size for either basket removal or for the passage of fragments postoperatively. We therefore sought to determine the accuracy of endoscopic assessment of renal calculi size. Between January and May 2013, five board-certified endourologists participated in an ex vivo artificial endoscopic simulation. A total of 10 stones (pebbles) were measured (mm) by nonparticipating urologist (N.D.P.) with electronic calibers and placed into separate labeled opaque test tubes to prevent visualization of the stones through the side of the tube. Endourologists were blinded to the actual size of the stones. A flexible digital ureteroscope with a 200-μm core sized laser fiber in the working channel as a size reference was placed through the ureteroscope into the test tube to estimate the stone size (mm). Accuracy was determined by obtaining the correlation coefficient (r) and constructing an Altman-Bland plot. Endourologists tended to overestimate actual stone size by a margin of 0.05 mm. The Pearson correlation coefficient was r=0.924, with a p-value<0.01. The estimation of small stones (<4 mm) had a greater accuracy than large stones (≥4 mm), r=0.911 vs r=0.666. Altman-bland plot analysis suggests that surgeons are able to accurately estimate stone size within a range of -1.8 to +1.9 mm. This ex vivo simulation study demonstrates that endoscopic assessment is reliable when assessing stone size. On average, there was a slight tendency to overestimate stone size by 0.05 mm. Most endourologists could visually estimate stone size within 2 mm of the actual size. These findings could be generalized to state that endourologists are accurately able to intraoperatively assess residual stone fragment size to guide decision making.

  12. Performance of a static-anode/flat-panel x-ray fluoroscopy system in a diagnostic strength magnetic field: a truly hybrid x-ray/MR imaging system.

    PubMed

    Fahrig, R; Wen, Z; Ganguly, A; DeCrescenzo, G; Rowlands, J A; Stevens, G M; Saunders, R F; Pelc, N J

    2005-06-01

    Minimally invasive procedures are increasing in variety and frequency, facilitated by advances in imaging technology. Our hybrid imaging system (GE Apollo flat panel, custom Brand x-ray static anode x-ray tube, GE Lunar high-frequency power supply and 0.5 T Signa SP) provides both x-ray and MR imaging capability to guide complex procedures without requiring motion of the patient between two distant gantries. The performance of the x-ray tube in this closely integrated system was evaluated by modeling and measuring both the response of the filament to an externally applied field and the behavior of the electron beam for field strengths and geometries of interest. The performance of the detector was assessed by measuring the slanted-edge modulation transfer function (MTF) and when placed at zero field and at 0.5 T. Measured resonant frequencies of filaments can be approximated using a modified vibrating beam model, and were at frequencies well below the 25 kHz frequency of our generator for our filament geometry. The amplitude of vibration was not sufficient to cause shorting of the filament during operation within the magnetic field. A simple model of electrons in uniform electric and magnetic fields can be used to estimate the deflection of the electron beam on the anode for the fields of interest between 0.2 and 0.5 T. The MTF measured at the detector and the DQE showed no significant difference inside and outside of the magnetic field. With the proper modifications, an x-ray system can be fully integrated with a MR system, with minimal loss of image quality. Any x-ray tube can be assessed for compatibility when placed at a particular location within the field using the models. We have also concluded that a-Si electronics are robust against magnetic fields. Detailed knowledge of the x-ray system installation is required to provide estimates of system operation.

  13. Feasibility evaluation of 3D photoacoustic imaging of blood vessel structure using multiple wavelengths with a handheld probe

    NASA Astrophysics Data System (ADS)

    Uchimoto, Yo; Namita, Takeshi; Kondo, Kengo; Yamakawa, Makoto; Shiina, Tsuyoshi

    2018-02-01

    Photoacoustic imaging is anticipated for use in portraying blood vessel structures (e.g. neovascularization in inflamed regions). To reduce invasiveness and enhance ease handling, we developed a handheld photoacoustic imaging system using multiple wavelengths. The usefulness of the proposed system was investigated in phantom experiments and in vivo measurements. A silicon tube was embedded into chicken breast meat to simulate the blood vessel. The tube was filled with ovine blood. Then laser light was guided to the phantom surface by an optical fiber bundle close to the linear ultrasound probe. Photoacoustic images were obtained at 750-950 nm wavelengths. Strong photoacoustic signals from the boundary between blood and silicon tube are observed in these images. The shape of photoacoustic spectrum at the boundary resembles that of the HbO2 absorption spectrum at 750-920 nm. In photoacoustic images, similarity between photoacoustic spectrum and HbO2 absorption spectrum was evaluated by calculating the normalized correlation coefficient. Results show high correlation in regions of strong photoacoustic signals in photoacoustic images. These analyses demonstrate the feasibility of portraying blood vessel structures under practical conditions. To evaluate the feasibility of three-dimensional vascular imaging, in vivo experiments were conducted using three wavelengths. A right hand and ultrasound probe were set in degassed water. By scanning a probe, cross-sectional ultrasound and photoacoustic images were obtained at each location. Then, all ultrasound or photoacoustic images were piled up respectively. Then three-dimensional images were constructed. Resultant images portrayed blood vessel-like structures three-dimensionally. Furthermore, to distinguish blood vessels from other tissues (e.g. skin), distinguishing images of them were constructed by comparing photoacoustic signal intensity among three wavelengths. The resultant image portrayed blood vessels as distinguished from surrounding tissues. These results demonstrated the usefulness of the proposed imaging device.

  14. Multiple tube premixing device

    DOEpatents

    Uhm, Jong Ho; Naidu, Balachandar; Ziminksy, Willy Steve; Kraemer, Gilbert Otto; Yilmaz, Ertan; Lacy, Benjamin; Stevenson, Christian; Felling, David

    2013-08-13

    The present application provides a premixer for a combustor. The premixer may include a fuel plenum with a number of fuel tubes and a burner tube with a number of air tubes. The fuel tubes extend about the air tubes.

  15. Multiple tube premixing device

    DOEpatents

    Uhm, Jong Ho; Varatharajan, Balachandar; Ziminsky, Willy Steve; Kraemer, Gilbert Otto; Yilmaz, Ertan; Lacy, Benjamin; Stevenson, Christian; Felling, David

    2012-12-11

    The present application provides a premixer for a combustor. The premixer may include a fuel plenum with a number of fuel tubes and a burner tube with a number of air tubes. The fuel tubes extend about the air tubes.

  16. YKL-40 in Serum Samples From Patients With Newly Diagnosed Stage III-IV Ovarian Epithelial, Primary Peritoneal Cavity, or Fallopian Tube Cancer Receiving Chemotherapy

    ClinicalTrials.gov

    2018-05-21

    Fallopian Tube Adenocarcinoma; Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Malignant Ovarian Brenner Tumor; Malignant Ovarian Clear Cell Tumor; Malignant Ovarian Endometrioid Tumor; Malignant Ovarian Mixed Epithelial Tumor; Malignant Ovarian Mucinous Tumor; Malignant Ovarian Neoplasm; Malignant Ovarian Serous Tumor; Malignant Ovarian Transitional Cell Tumor; Ovarian Adenocarcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma

  17. Internal baffling for fuel injector

    DOEpatents

    Johnson, Thomas Edward; Lacy, Benjamin; Stevenson, Christian

    2014-08-05

    A fuel injector includes a fuel delivery tube; a plurality of pre-mixing tubes, each pre-mixing tube comprising at least one fuel injection hole; an upstream tube support plate that supports upstream ends of the plurality of pre-mixing tubes; a downstream tube support plate that supports downstream ends of the plurality of pre-mixing tubes; an outer wall connecting the upstream tube support plate and the downstream tube support plate and defining a plenum therewith; and a baffle provided in the plenum. The baffle includes a radial portion. A fuel delivered in the upstream direction by the fuel delivery tube is directed radially outwardly in the plenum between the radial portion of the baffle and the downstream tube support plate, then in the downstream direction around an outer edge portion of the radial portion, and then radially inwardly between the radial portion and the upstream tube support plate.

  18. Numerical Investigation of the Impact of the Compressor Operation Mode on Working Process of the Combustion Chamber

    NASA Astrophysics Data System (ADS)

    Orlov, M. Yu; Lukachev, S. V.; Anisimov, V. M.

    2018-01-01

    The method of integrated compressor/combustor simulation was used to investigate the impact of flow distortion, appeared due to compressor blades, during the combustion chamber workflow. The method was improved in terms of generating a common grid and of principles of the boundary conditions settings. The geometric model includes four geometric volume bodies: guide vanes of the penultimate stage of high-pressure compressor, the impeller and guide vanes of the last stage and the flow path of combustion chamber. The calculation was carried out for some operation mode of the engine (nominal, 0.7 of nominal and 0.5 of nominal regimes) with and without compressor. The results were compared with the results of combustion chamber simulation without the compressor. Simulations showed that blade wakes extend up to the flame tube head. These wakes influence on the flame tongue, pressure field, temperature and velocity in the recirculation-mixing zone. It can influence on combustion efficiency, ecological performance and on temperature field at the combustor outlet. Thus, the simulations, which take into account combustion chamber and compressor, are more fully represent the characteristics of the working process of the combustion chamber and increase the efficiency of the design of new products.

  19. Linear ordered collagen scaffolds loaded with collagen-binding basic fibroblast growth factor facilitate recovery of sciatic nerve injury in rats.

    PubMed

    Ma, Fukai; Xiao, Zhifeng; Chen, Bing; Hou, Xianglin; Dai, Jianwu; Xu, Ruxiang

    2014-04-01

    Natural biological functional scaffolds, consisting of biological materials filled with promoting elements, provide a promising strategy for the regeneration of peripheral nerve defects. Collagen conduits have been used widely due to their excellent biological properties. Linear ordered collagen scaffold (LOCS) fibers are good lumen fillers that can guide nerve regeneration in an ordered direction. In addition, basic fibroblast growth factor (bFGF) is important in the recovery of nerve injury. However, the traditional method for delivering bFGF to the lesion site has no long-term effect because of its short half-life and rapid diffusion. Therefore, we fused a specific collagen-binding domain (CBD) peptide to the N-terminal of native basic fibroblast growth factor (NAT-bFGF) to retain bFGF on the collagen scaffolds. In this study, a natural biological functional scaffold was constructed using collagen tubes filled with collagen-binding bFGF (CBD-bFGF)-loaded LOCS to promote regeneration in a 5-mm rat sciatic nerve transection model. Functional evaluation, histological investigation, and morphometric analysis indicated that the natural biological functional scaffold retained more bFGF at the injury site, guided axon growth, and promoted nerve regeneration as well as functional restoration.

  20. Application of MR-guided focused pulsed ultrasound for destroying clots in vitro using thrombolytic drugs

    NASA Astrophysics Data System (ADS)

    Hadjisavvas, V.; Ioannides, K.; Damianou, C.

    2011-09-01

    In this paper an MR-guided focused pulsed ultrasound system for the treatment of stroke using thrombolytic drugs in a model in vitro is presented. A single element spherically focused transducer of 5 cm diameter; focusing at 10 cm and operating at 0.5 MHz or 1 MHz was used. The transducer was mounted in an MR compatible robot. The artery was modelled using a silicone tube. Tissue was modelled using polyaclylimide gel. Coagulated blood was used to model thrombus. A thermocouple was placed in the thrombus in order to measure the thrombus temperature. The effect of power, beam, and frequency was investigated. The goal was to maintain a temperature increase of less than 1 °C during the application of pulse ultrasound (called safe temperature). With the application of ultrasound alone there was no notable destruction of the thrombus. With the combination of ultrasound and thrombolytic drugs destruction occurred after 60 mins of pulse exposure (PRF = 1 s, duty factor = 10%, and with thrombus placed at 1 cm deep in the tissue). This simple in vitro model was proven very successful for evaluating MRgFUS as a modality for treating stroke. In the future we plan to apply this treatment protocol in live animals and humans.

  1. Light-emitting diode-based multiwavelength diffuse optical tomography system guided by ultrasound

    PubMed Central

    Yuan, Guangqian; Alqasemi, Umar; Chen, Aaron; Yang, Yi; Zhu, Quing

    2014-01-01

    Abstract. Laser diodes are widely used in diffuse optical tomography (DOT) systems but are typically expensive and fragile, while light-emitting diodes (LEDs) are cheaper and are also available in the near-infrared (NIR) range with adequate output power for imaging deeply seated targets. In this study, we introduce a new low-cost DOT system using LEDs of four wavelengths in the NIR spectrum as light sources. The LEDs were modulated at 20 kHz to avoid ambient light. The LEDs were distributed on a hand-held probe and a printed circuit board was mounted at the back of the probe to separately provide switching and driving current to each LED. Ten optical fibers were used to couple the reflected light to 10 parallel photomultiplier tube detectors. A commercial ultrasound system provided simultaneous images of target location and size to guide the image reconstruction. A frequency-domain (FD) laser-diode-based system with ultrasound guidance was also used to compare the results obtained from those of the LED-based system. Results of absorbers embedded in intralipid and inhomogeneous tissue phantoms have demonstrated that the LED-based system provides a comparable quantification accuracy of targets to the FD system and has the potential to image deep targets such as breast lesions. PMID:25473884

  2. Assessment of Soft Vane and Metal Foam Engine Noise Reduction Concepts

    NASA Technical Reports Server (NTRS)

    Jones, Michael G.; Parrott, Tony L.; Sutliff, Daniel L.; Hughes, Chris

    2009-01-01

    Two innovative fan-noise reduction concepts developed by NASA are presented - soft vanes and over-the-rotor metal foam liners. Design methodologies are described for each concept. Soft vanes are outlet guide vanes with internal, resonant chambers that communicate with the exterior aeroacoustic environment via a porous surface. They provide acoustic absorption via viscous losses generated by interaction of unsteady flows with the internal solid structure. Over-the-rotor metal foam liners installed at or near the fan rotor axial plane provide rotor noise absorption. Both concepts also provide pressure-release surfaces that potentially inhibit noise generation. Several configurations for both concepts are evaluated with a normal incidence tube, and the results are used to guide designs for implementation in two NASA fan rigs. For soft vanes, approximately 1 to 2 dB of broadband inlet and aft-radiated fan noise reduction is achieved. For over-the-rotor metal foam liners, up to 3 dB of fan noise reduction is measured in the low-speed fan rig, but minimal reduction is measured in the high-speed fan rig. These metal foam liner results are compared with a static engine test, in which inlet sound power level reductions up to 5 dB were measured. Brief plans for further development are also provided.

  3. Negotiated media effects. Peer feedback modifies effects of media's thin-body ideal on adolescent girls.

    PubMed

    Veldhuis, Jolanda; Konijn, Elly A; Seidell, Jacob C

    2014-02-01

    The present study introduces a theoretical framework on negotiated media effects. Specifically, we argue that feedback of peers on thin-body ideal media images and individual dispositions guide effects on adolescent girls' psychosocial responses to media exposure. Therefore, we examined the thin-body ideal as portrayed in media and peers' feedback on such thin-ideal images in their combined effects on adolescent girls' body dissatisfaction, objectified body consciousness, and social comparison with media models. Hence, media models and peer comments were systematically combined as incorporated entities in YouTube-formats. Hypotheses were tested in a 3 (media models: extremely thin vs. thin vs. normal weight)×3 (peer comments: 6kg-underweight vs. 3kg-underweight vs. normal-weight)×2 (appearance schematicity: lower vs. higher) between-subjects design (N=216). Results showed that peer comments indicating that a media model was 'only 3kg-underweight' exerted most negative responses, particularly in girls who strongly process appearance relevant information. Peer feedback interacts with media models in guiding perceptions of what is considered an 'ideal' body shape. Results highlight the important role of peers as well as individual predispositions in view of understanding how thin-ideal media images may impact adolescent girls' body image concerns. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. OPT-821 With or Without Vaccine Therapy in Treating Patients With Ovarian Epithelial Cancer, Fallopian Tube Cancer, or Peritoneal Cancer in Second or Third Complete Remission

    ClinicalTrials.gov

    2017-09-12

    Stage IA Fallopian Tube Cancer; Stage IA Ovarian Cancer; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Cancer; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer

  5. Multi-tube arrangement for combustor and method of making the multi-tube arrangement

    DOEpatents

    Ziminsky, Willy Steve [Simpsonville, SC

    2012-07-31

    A fuel injector tube includes a one piece, unitary, polygonal tube having an inlet end and an outlet end. The fuel injector tube further includes a fuel passage extending from the inlet end to the outlet end along a longitudinal axis of the polygonal tube, a plurality of air passages extending from the inlet end to the outlet end and surrounding the fuel passage, and a plurality of fuel holes. Each fuel hole connects an air passage with the fuel passage. The inlet end of the polygonal tube is formed into a fuel tube. A fuel injector includes a plurality of fuel injector tubes and a plate. The plurality of fuel tubes are connected to the plate adjacent the inlet ends of the plurality of fuel injector tubes.

  6. Carboplatin and Paclitaxel With or Without Bevacizumab in Treating Patients With Stage III or Stage IV Ovarian Epithelial, Primary Peritoneal, or Fallopian Tube Cancer

    ClinicalTrials.gov

    2017-10-23

    Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Malignant Ovarian Mixed Epithelial Tumor; Ovarian Brenner Tumor; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma

  7. Managing a chest tube and drainage system.

    PubMed

    Durai, Rajaraman; Hoque, Happy; Davies, Tony W

    2010-02-01

    Intercostal drainage tubes (ie, chest tubes) are inserted to drain the pleural cavity of air, blood, pus, or lymph. The water-seal container connected to the chest tube allows one-way movement of air and liquid from the pleural cavity. The container should not be changed unless it is full, and the chest tube should not be clamped unnecessarily. After a chest tube is inserted, a nurse trained in chest-tube management is responsible for managing the chest tube and drainage system. This entails monitoring the chest-tube position, controlling fluid evacuation, identifying when to change or empty the containers, and caring for the tube and drainage system during patient transport. This article provides an overview of indications, insertion techniques, and management of chest tubes. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  8. Tube-in-tube thermophotovoltaic generator

    DOEpatents

    Ashcroft, J.; Campbell, B.; DePoy, D.

    1998-06-30

    A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell. 8 figs.

  9. 75 FR 64696 - Circular Welded Carbon Steel Pipes and Tubes From Thailand: Final Results of Antidumping Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-20

    ... Pipes and Tubes From Thailand: Final Results of Antidumping Duty Administrative Review AGENCY: Import... Thailand. The review was requested by Allied Tube and Conduit Corporation (Allied Tube), by Wheatland Tube... antidumping duty order on pipes and tubes from Thailand. See Circular Welded Carbon Steel Pipes and Tubes from...

  10. Rolling-Tooth Core Breakoff and Retention Mechanism

    NASA Technical Reports Server (NTRS)

    Badescu, Mircea; Bickler, Donald B.; Sherrit, Stewart; Bar-Cohen, Yoseph; Bao, Xiaoqi; Hudson, Nicolas H.

    2011-01-01

    Sampling cores requires the controlled breakoff of the core at a known location with respect to the drill end. An additional problem is designing a mechanism that can be implemented at a small scale that is robust and versatile enough to be used for a variety of core samples. This design consists of a set of tubes (a drill tube and an inner tube) and a rolling element (rolling tooth). An additional tube can be used as a sample tube. The drill tube and the inner tube have longitudinal holes with the axes offset from the axis of each tube. The two eccentricities are equal. The inner tube fits inside the drill tube, and the sample tube fits inside the inner tube. While drilling, the two tubes are positioned relative to each other such that the sample tube is aligned with the drill tube axis and core. The drill tube includes teeth and flutes for cuttings removal. The inner tube includes, at the base, the rolling element implemented as a wheel on a shaft in an eccentric slot. An additional slot in the inner tube and a pin in the drill tube limit the relative motion of the two tubes. While drilling, the drill assembly rotates relative to the core and forces the rolling tooth to stay hidden in the slot along the inner tube wall. When the drilling depth has been reached, the drill bit assembly is rotated in the opposite direction, and the rolling tooth is engaged and penetrates into the core. Depending on the strength of the created core, the rolling tooth can score, lock the inner tube relative to the core, start the eccentric motion of the inner tube, and break the core. The tooth and the relative position of the two tubes can act as a core catcher or core-retention mechanism as well. The design was made to fit the core and hole parameters produced by an existing bit; the parts were fabricated and a series of demonstration tests were performed. This invention is potentially applicable to sample return and in situ missions to planets such as Mars and Venus, to moons such as Titan and Europa, and to comets. It is also applicable to terrestrial applications like forensic sampling and geological sampling in the field.

  11. Influence of resonance tube geometry shape on performance of thermoacoustic engine.

    PubMed

    Bao, Rui; Chen, Guobang; Tang, Ke; Jia, Zhengzhong; Cao, Weihua

    2006-12-22

    Based on the linear thermoacoustics, a symmetrical standing-wave thermoacoustic engine is simulated with a cylindrical tube and a tapered one as the resonance tube, respectively. The experiments with both cylindrical and tapered tubes are carried out. The suppression of nonlinear effects due to tapered tube as the resonance tube is discussed. Both simulation and experimental results show that the performance of the tapered tube is better than cylindrical one as the resonance tube.

  12. Differential effect of blood collection tubes on total free fatty acids (FFA) and total triiodothyronine (TT3) concentration: a model for studying interference from tube constituents.

    PubMed

    Bowen, Raffick A R; Vu, Chi; Remaley, Alan T; Hortin, Glen L; Csako, Gyorgy

    2007-03-01

    Besides total triiodothyronine (TT3), total free fatty acids (FFA) concentrations were higher with serum separator tube (SST) than Vacuette tubes. The effects of surfactant, rubber stopper, and separator gel from various tubes were investigated on FFA, beta-hydroxybutyrate (beta-HB), and TT3 with 8 different tube types in blood specimens of apparently healthy volunteers. Compared to Vacuette tubes, serum FFA and TT3 concentrations were significantly higher in SST than glass tubes. Reformulated SST eliminated the increase in TT3 but not FFA. No significant difference was observed for beta-HB concentration among tube types. Surfactant and rubber stoppers from the different tube types significantly increased TT3 but not FFA and beta-HB concentrations. Agitation of whole blood but not serum or plasma specimens with separator gel from SST, reformulated SST and plasma preparation tube (PPT) tubes compared to Vacuette tubes gave higher FFA but not beta-HB levels. Unidentified component(s) from the separator gel in SST, reformulated SST and PPT tubes cause falsely high FFA concentration. In contrast to TT3, falsely high FFA results require exposure of whole blood and not serum to tube constituent(s). The approach employed here may serve as a model for assessing interference(s) from tube constituent(s).

  13. [Use of the Pentax-AWS videolaryngoscope for bougie-assisted exchange of tracheal tubes].

    PubMed

    Kishii, Miki; Asai, Takashi; Nagata, Atsushi; Shingu, Koh

    2009-06-01

    A gum elastic bougie can be useful for tube exchange. One major problem with this technique is that it may not possible to pass a new tube over the bougie into the trachea, because the tip of the tube can collide with tissues around the glottis. We report a case in which tube exchange using the bougie was difficult, but the Pentax-AWS videolaryngoscope enabled tracheal intubation. In a 62-year-old trauma patient with head and neck stabilized using a Halo vest, was scheduled for emergency fixation of the neck. Exchange of a polyvinylchloride tube to a reinforced tube was planned. A bougie was passed through the old tube, removing the tube, and a new tube was advanced over the bougie, but it was impossible to advance the tube into the trachea. Insertion of a Macintosh laryngoscope did not enable intubation. The new tube was removed from the bougie, attached to the Pentax-AWS videolaryngoscope, and the tube (with the Pentax-AWS) was passed over the bougie. Although it was not possible to see the glottis with the Pentax-AWS, the tube was easily advanced over the bougie into the trachea. Operation went on uneventfully. We believe that, when it is difficult to advance a tracheal tube over a tube exchanger, the use of the Pentax-AWS may facilitate intubation.

  14. Texture control of zircaloy tubing during tube reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagai, N.; Kakuma, T.; Fujita, K.

    1982-01-01

    Seven batches of Zircaloy-2 nuclear fuel cladding tubes with different textures were processed from tube shells of the same size, by different reduction routes, using pilger and 3-roll mills. Based on the texture data of these tubes, the texture control of Zircaloy tubing, the texture gradient across the wall, and the texture change during annealing were studied. The deformation texture of Zicaloy-2 tubing was dependent on the tool's curvature and was independent of the dimensions of the mother tubes. The different slopes of texture gradients were observed between the tubing of higher strain ration and that of lower strain ratio.

  15. A Novel Technique of a Transcorneal Suture to Manage an Iris Tuck into the Tube of a Glaucoma Drainage Device.

    PubMed

    Kataria, Pankaj; Kaushik, Sushmita; Singh, Simar R; Pandav, Surinder S

    2016-08-01

    Glaucoma drainage devices create an alternative pathway of aqueous drainage from the anterior chamber by channelling aqueous out of the eye through a tube to a subconjunctival bleb or the suprachoroidal space. They may be associated with a number of potential complications including tube malpositioning. This malpositioning may have serious sequelae such as corneal endothelial damage, chronic iritis, tube iris touch, cataract formation, or tube occlusion. Occlusion of the mouth of the tube by the iris impedes aqueous drainage and results in the failure of intraocular pressure (IOP) control. Tube repositioning in cases of occlusion of the mouth of the tube by the iris often involves extensive and potentially complicated surgery requiring tube removal and reinsertion. We describe a new minimally invasive surgical technique for correcting posterior tube malposition resulting in tube occlusion by the iris. The iris had occluded the tube of a Baerveldt prototype glaucoma drainage devices and caused an intractable increased IOP. After our tube sling suture, the tube was free, and the IOP normalized. The procedure entailed no difficult dissection or major surgical intervention. The technique is illustrated by a surgical video. This novel technique is a simple method that relieved the occlusion successfully, and avoided the need to redissect the conjunctiva or shorten the tube.

  16. Apparatus and method to compensate for refraction of radiation

    DOEpatents

    Allen, Gary R.; Moskowitz, Philip E.

    1990-01-01

    An apparatus to compensate for refraction of radiation passing through a curved wall of an article is provided. The apparatus of a preferred embodiment is particularly advantageous for use in arc tube discharge diagnostics. The apparatus of the preferred embodiment includes means for pre-refracting radiation on a predetermined path by an amount equal and inverse to refraction which occurs when radiation passes through a first wall of the arc tube such that, when the radiation passes through the first wall of the arc tube and into the cavity thereof, the radiation passes through the cavity approximately on the predetermined path; means for releasably holding the article such that the radiation passes through the cavity thereof; and means for post-refracting radiation emerging from a point of the arc tube opposite its point of entry by an amount equal and inverse to refraction which occurs when radiation emerges from the arc tube. In one embodiment the means for pre-refracting radiation includes a first half tube comprising a longitudinally bisected tube obtained from a tube which is approximately identical to the arc tube's cylindrical portion and a first cylindrical lens, the first half tube being mounted with its concave side facing the radiation source and the first cylindrical lens being mounted between the first half tube and the arc tube and the means for post-refracting radiation includes a second half tube comprising a longitudinally bisected tube obtained from a tube which is approximately identical to the arc tube's cylindrical portion and a second cylindrical lens, the second half tube being mounted with its convex side facing the radiation source and the second cylindrical lens being mounted between the arc tube and the second half tube. Methods to compensate for refraction of radiation passing into and out of an arc tube is also provided.

  17. Apparatus and method to compensate for refraction of radiation

    DOEpatents

    Allen, G.R.; Moskowitz, P.E.

    1990-03-27

    An apparatus to compensate for refraction of radiation passing through a curved wall of an article is provided. The apparatus of a preferred embodiment is particularly advantageous for use in arc tube discharge diagnostics. The apparatus of the preferred embodiment includes means for pre-refracting radiation on a predetermined path by an amount equal and inverse to refraction which occurs when radiation passes through a first wall of the arc tube such that, when the radiation passes through the first wall of the arc tube and into the cavity thereof, the radiation passes through the cavity approximately on the predetermined path; means for releasably holding the article such that the radiation passes through the cavity thereof; and means for post-refracting radiation emerging from a point of the arc tube opposite its point of entry by an amount equal and inverse to refraction which occurs when radiation emerges from the arc tube. In one embodiment the means for pre-refracting radiation includes a first half tube comprising a longitudinally bisected tube obtained from a tube which is approximately identical to the arc tube's cylindrical portion and a first cylindrical lens, the first half tube being mounted with its concave side facing the radiation source and the first cylindrical lens being mounted between the first half tube and the arc tube and the means for post-refracting radiation includes a second half tube comprising a longitudinally bisected tube obtained from a tube which is approximately identical to the arc tube's cylindrical portion and a second cylindrical lens, the second half tube being mounted with its convex side facing the radiation source and the second cylindrical lens being mounted between the arc tube and the second half tube. Methods to compensate for refraction of radiation passing into and out of an arc tube is also provided. 4 figs.

  18. Pembrolizumab, Bevacizumab, and Cyclophosphamide in Treating Patients With Recurrent Ovarian, Fallopian Tube, or Primary Peritoneal Cancer

    ClinicalTrials.gov

    2018-05-03

    Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Serous Adenocarcinoma; Primary Peritoneal Serous Adenocarcinoma; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma

  19. Liquid-Nitrogen Test for Blocked Tubes

    NASA Technical Reports Server (NTRS)

    Wagner, W. R.

    1984-01-01

    Nondestructive test identifies obstructed tube in array of parallel tubes. Trickle of liquid nitrogen allowed to flow through tube array until array accumulates substantial formation of frost from moisture in air. Flow stopped and warm air introduced into inlet manifold to heat tubes in array. Tubes still frosted after others defrosted identified as obstructed tubes. Applications include inspection of flow systems having parallel legs.

  20. System and method having multi-tube fuel nozzle with differential flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, Michael John; Johnson, Thomas Edward; Berry, Jonathan Dwight

    A system includes a multi-tube fuel nozzle with a fuel nozzle body and a plurality of tubes. The fuel nozzle body includes a nozzle wall surrounding a chamber. The plurality of tubes extend through the chamber, wherein each tube of the plurality of tubes includes an air intake portion, a fuel intake portion, and an air-fuel mixture outlet portion. The multi-tube fuel nozzle also includes a differential configuration of the air intake portions among the plurality of tubes.

Top